Sample records for absorbance detection electrospray

  1. Production and properties of electrosprayed sericin nanopowder

    NASA Astrophysics Data System (ADS)

    Hazeri, Najmeh; Tavanai, Hossein; Moradi, Ali Reza

    2012-06-01

    Sericin is a proteinous substrate that envelops fibroin (silk) fiber, and its recovery provides significant economical and social benefits. Sericin is an antibacterial agent that resists oxidation and absorbs moisture and UV light. In powder form, sericin has a wide range of applications in food, cosmetics and drug delivery. Asides from other techniques of producing powder, such as precipitation and spray drying, electrospraying can yield solid nanoparticles, particularly in the submicron range. Here, we report the production of sericin nanopowder by electrospraying. Sericin sponge was recovered from Bombyx mori cocoons through a high-temperature, high-pressure process, followed by centrifugation and freeze drying of the sericin solution. The electrospraying solution was prepared by dissolving the sericin sponge in dimethyl sulfoxide. We demonstrate that electrospraying is capable of producing sericin nanopowder with an average particle size of 25 nm, which is by far smaller than the particles produced by other techniques. The electrosprayed sericin nanopowder consists of small crystallites and exhibits a high moisture absorbance.

  2. Screening and analysis of the multiple absorbed bioactive components and metabolites in rat plasma after oral administration of Jitai tablets by high-performance liquid chromatography/diode-array detection coupled with electrospray ionization tandem mass spectrometry.

    PubMed

    Wang, Shu-Ping; Liu, Lei; Wang, Ling-Ling; Jiang, Peng; Zhang, Ji-Quan; Zhang, Wei-Dong; Liu, Run-Hui

    2010-06-15

    Based on the serum pharmacochemistry technique and high-performance liquid chromatography/diode-array detection (HPLC/DAD) coupled with electrospray tandem mass spectrometry (HPLC/ESI-MS/MS), a method for screening and analysis of the multiple absorbed bioactive components and metabolites of Jitai tablets (JTT) in orally dosed rat plasma was developed. Plasma was treated by methanol precipitation prior to liquid chromatography, and the separation was carried out on a Symmetry C(18) column, with a linear gradient (0.1% formic acid/water/acetonitrile). Mass spectra were acquired in negative and positive ion modes, respectively. As a result, 26 bioactive components originated from JTT and 5 metabolites were tentatively identified in orally dosed rat plasma by comparing their retention times and MS spectra with those of authentic standards and literature data. It is concluded that an effective and reliable analytical method was set up for screening the bioactive components of Chinese herbal medicine, which provided a meaningful basis for further pharmacology and active mechanism research of JTT. Copyright (c) 2010 John Wiley & Sons, Ltd.

  3. Comparison of Internal Energy Distributions of Ions Created by Electrospray Ionization and Laser Ablation-Liquid Vortex Capture-Electrospray Ionization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cahill, John F.; Kertesz, Vilmos; Ovchinnikova, Olga S.

    2015-06-27

    Recently a number of techniques have combined laser ablation with liquid capture for mass spectrometry spot sampling and imaging applications. The newly developed non-contact liquid-vortex capture probe has been used to efficiently collect 355 nm UV laser ablated material in a continuous flow solvent stream in which the captured material dissolves and then undergoes electrospray ionization. This sampling and ionization approach has produced what appear to be classic electrospray ionization spectra; however, the softness of this sampling/ionization process versus simple electrospray ionization has not been definitely determined. A series of benzlypyridinium salts, known as thermometer ions, were used to comparemore » internal energy distributions between electrospray ionization and the UV laser ablation liquid-vortex capture probe electrospray combination. Measured internal energy distributions were identical between the two techniques, even with differences in laser fluence (0.7-3.1 J cm-2) and when using UV-absorbing or non-UV-absorbing sample substrates. This data indicates ions formed directly by UV laser ablation, if any, are likely an extremely small constituent of the total ion signal observed. Instead, neutral molecules, clusters or particulates ejected from the surface during laser ablation, subsequently captured and dissolved in the flowing solvent stream then electrosprayed are the predominant source of ion signal observed. The electrospray ionization process used controls the softness of the technique.« less

  4. Simultaneous separation and identification of oligomeric procyanidins and anthocyanin-derived pigments in raw red wine by HPLC-UV-ESI-MSn.

    PubMed

    Pati, S; Losito, I; Gambacorta, G; La Notte, E; Palmisano, F; Zambonin, P G

    2006-07-01

    Samples of raw red wine (Primitivo di Manduria, Apulia, Southern Italy) were analysed without any pre-treatment (except 1:2 dilution with water) using HPLC with detection based on UV absorbance and Electrospray Ionisation Sequential Mass Spectrometry (ESI-MSn, with n = 1-3) in a series configuration. In particular, absorbance at 520 nm was monitored for UV detection in order to identify pigments responsible for wine colour. On the other hand, two subsequent stages of MS detection based on positive ions were adopted. The first consisted of an explorative MS acquisition, aimed at the individuation of the m/z ratios for positively charged compounds; the second was based on fragmentation of the detected ions within an ion trap analyser, followed by MS/MS and, if required, MS3 acquisitions. The synergy between UV detection and MSn analysis led to the identification of 41 pigments, which can be classified into five groups: grape anthocyanins, pyranoanthocyanins, vinyl-linked anthocyanin-flavanol pigments, ethyl-bridged anthocyanin-flavanol pigments and flavanol-anthocyanin compounds. Many isomeric and oligomeric structures were found within each group. A further class of compounds, not absorbing in the visible spectrum, could be also characterised by ESI-MSn and corresponded to B-type procyanidins, i.e. proanthocyanidins arising from C4-->C8/C4-->C6 couplings between catechin or epicatechin units. In particular, oligomeric structures (from dimers to pentamers), often present with several isomers, were identified and their fragmentation patterns clarified.

  5. Nitrogen-Containing, Light-Absorbing Oligomers Produced in Aerosol Particles Exposed to Methylglyoxal, Photolysis, and Cloud Cycling.

    PubMed

    De Haan, David O; Tapavicza, Enrico; Riva, Matthieu; Cui, Tianqu; Surratt, Jason D; Smith, Adam C; Jordan, Mary-Caitlin; Nilakantan, Shiva; Almodovar, Marisol; Stewart, Tiffany N; de Loera, Alexia; De Haan, Audrey C; Cazaunau, Mathieu; Gratien, Aline; Pangui, Edouard; Doussin, Jean-François

    2018-04-03

    Aqueous methylglyoxal chemistry has often been implicated as an important source of oligomers in atmospheric aerosol. Here we report on chemical analysis of brown carbon aerosol particles collected from cloud cycling/photolysis chamber experiments, where gaseous methylglyoxal and methylamine interacted with glycine, ammonium, or methylammonium sulfate seed particles. Eighteen N-containing oligomers were identified in the particulate phase by liquid chromatography/diode array detection/electrospray ionization high-resolution quadrupole time-of-flight mass spectrometry. Chemical formulas were determined and, for 6 major oligomer products, MS 2 fragmentation spectra were used to propose tentative structures and mechanisms. Electronic absorption spectra were calculated for six tentative product structures by an ab initio second order algebraic-diagrammatic-construction/density functional theory approach. For five structures, matching calculated and measured absorption spectra suggest that they are dominant light-absorbing species at their chromatographic retention times. Detected oligomers incorporated methylglyoxal and amines, as expected, but also pyruvic acid, hydroxyacetone, and significant quantities of acetaldehyde. The finding that ∼80% (by mass) of detected oligomers contained acetaldehyde, a methylglyoxal photolysis product, suggests that daytime methylglyoxal oligomer formation is dominated by radical addition mechanisms involving CH 3 CO*. These mechanisms are evidently responsible for enhanced browning observed during photolytic cloud events.

  6. Liquid Chromatography-Mass Spectrometry Interface for Detection of Extraterrestrial Organics

    NASA Technical Reports Server (NTRS)

    Southard, Adrian E.; Getty, Stephanie A.; Balvin, Manuel; Cook, Jamie E.; Espiritu, Ana Mellina; Kotecki, Carl; Towner, Deborah W.; Dworkin, J. P.; Glavin, Daniel P.; Mahaffy, Paul R.; hide

    2014-01-01

    The OASIS (Organics Analyzer for Sampling Icy surfaces) microchip enables electrospray or thermospray of analyte for subsequent analysis by the OASIS time-of-flight mass spectrometer. Electrospray of buffer solution containing the nucleobase adenine was performed using the microchip and detected by a commercial time-of-flight mass spectrometer. Future testing of thermospray and electrospray capability will be performed using a test fixture and vacuum chamber developed especially for optimization of ion spray at atmosphere and in low pressure environments.

  7. Recent developments in cyanide detection: A review

    PubMed Central

    Ma, Jian; Dasgupta, Purnendu K.

    2010-01-01

    The extreme toxicity of cyanide and environmental concerns from its continued industrial use continue to generate interest in facile and sensitive methods for cyanide detection. In recent years there is also additional recognition of HCN toxicity from smoke inhalation and potential use of cyanide as a weapon of terrorism. This review summarizes the literature since 2005 on cyanide measurement in different matrices ranging from drinking water and wastewater, to cigarette smoke and exhaled breath to biological fluids like blood, urine and saliva. The dramatic increase in the number of publications on cyanide measurement is indicative of the great interest in this field not only from analytical chemists, but also researchers from diverse environmental, medical, forensic and clinical arena. The recent methods cover both established and emerging analytical disciplines and include naked eye visual detection, spectrophotometry/colorimetry, capillary electrophoresis with optical absorbance detection, fluorometry, chemiluminescence, near-infrared cavity ring down spectroscopy, atomic absorption spectrometry, electrochemical methods (potentiometry/amperometry/ion chromatography-pulsed amperometry), mass spectrometry (selected ion flow tube mass spectrometry, electrospray ionization mass spectrometry, gas chromatography-mass spectrometry), gas chromatography (nitrogen phosphorus detector, electron capture detector) and quartz crystal mass monitors. PMID:20599024

  8. Water Contaminant Mitigation in Ionic Liquid Propellant

    NASA Technical Reports Server (NTRS)

    Conroy, David; Ziemer, John

    2009-01-01

    Appropriate system and operational requirements are needed in order to ensure mission success without unnecessary cost. Purity requirements applied to thruster propellants may flow down to materials and operations as well as the propellant preparation itself. Colloid electrospray thrusters function by applying a large potential to a room temperature liquid propellant (such as an ionic liquid), inducing formation of a Taylor cone. Ions and droplets are ejected from the Taylor cone and accelerated through a strong electric field. Electrospray thrusters are highly efficient, precise, scaleable, and demonstrate low thrust noise. Ionic liquid propellants have excellent properties for use as electrospray propellants, but can be hampered by impurities, owing to their solvent capabilities. Of foremost concern is the water content, which can result from exposure to atmosphere. Even hydrophobic ionic liquids have been shown to absorb water from the air. In order to mitigate the risks of bubble formation in feed systems caused by water content of the ionic liquid propellant, physical properties of the ionic liquid EMI-Im are analyzed. The effects of surface tension, material wetting, physisorption, and geometric details of the flow manifold and electrospray emitters are explored. Results are compared to laboratory test data.

  9. Systematic Analysis of Main Constituents in Rat Biological Samples after Oral Administration of the Methanol Extract of Fructus Aurantii by HPLC-ESI-MS/MS.

    PubMed

    Zhang, Jingze; Gao, Wenyuan; Liu, Zhen; Zhang, Zhidan; Liu, Changxiao

    2014-01-01

    High performance liquid chromatography (HPLC) with diode array detection (DAD) and electrospray ionization tandem mass spectrometry (ESI/MS/MS) was used to analyze the main components in the methanol extract of Fructus Aurantii (FA) and the metabolites in rat biological samples after oral administration of the methanol extract of FA. There were 31 constituents identified in the extract of FA including 2 alkaloids, 1 coumarin, 10 flavonoid glycosides and 18 ploymethoxylated flavones. According to the UV spectrum and MS fragment character of main components in the methanol extract of FA, 18 parent constituents and 11 metabolites were tentatively identified in rat biological samples. Three groups of components in biological samples detected included flavonoid glycosides, their glucuronides and ploymethoxylated flavones. It was interested that flavonoid glycosides, their glucuronides and ploymethoxylated flavones can be investigated in rat plasma and urine, while in rat feces samples only flavonoid glycosides were detected. Triglycosyl, naringenin, neoeriocitrin, neoeriocitrin narirutin and hesperidin were the main components in rat feces which were found either in the plasma or in urine samples. However, naringin and neohesperidin were the main flavonoid glycosides which absorbed after oral administration. Except flavonoid glycosides and their glucuronides, ploymethoxylated flavones also the constituents absorbed because it was investigated mainly in rat plasma and urine but not in feces samples. The identification and elucidation of parent and metabolism components analyzed in biological samples provided the data for further pharmacological and clinical research on FA.

  10. Laser-Induced Breakdown Spectroscopy: A Review of Applied Explosive Detection

    DTIC Science & Technology

    2013-09-01

    Based Techniques ..........................................................................................7 2.5 Ion Mobility and Mass Spectrometry...proximal trace detection. We show that the algorithms for material identification could be improved by including the critical signatures (e.g., C2...IMS), desorption electrospray ionization (DESI), laser electrospray mass spectrometry (LEMS), emerging efforts like antibody/antigen-based efforts

  11. Detection of trace ink compounds in erased handwritings using electrospray-assisted laser desorption ionization mass spectrometry.

    PubMed

    Kao, Yi-Ying; Cheng, Sy-Chyi; Cheng, Chu-Nian; Shiea, Jentaie; Ho, Hsiu-O

    2014-06-01

    Writings made with erasable pens on paper surfaces can either be rubbed off with an eraser or rendered invisible by changing the temperature of the ink. However, trace ink compounds still remain in the paper fibers even after rubbing or rendering. The detection of these ink compounds from erased handwritings will be helpful in knowing the written history of the paper. In this study, electrospray-assisted laser desorption ionization/mass spectrometry was used to characterize trace ink compounds remaining in visible and invisible ink lines. The ink compounds were desorbed from the paper surface by irradiating the handwritings with a pulsed laser beam; the desorbed analytes were subsequently ionized in an electrospray plume and detected by a quadrupole time-of-flight mass spectrometry mass analyzer. Because of the high spatial resolution of the laser beam, electrospray-assisted laser desorption ionization/mass spectrometry analysis resulted in minimal damage to the sample documents. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Probing the Mechanisms of an Air Amplifier using a LTQ-FT-ICR-MS and Fluorescence Spectroscopy

    PubMed Central

    Dixon, R. Brent; Muddiman, David C.; Hawkridge, Adam M.; Fedorov, A. G.

    2008-01-01

    We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid linear ion trap Fourier transform ion cyclotron resonance mass spectrometer (ESI-LTQ-FT-ICR-MS). A solution of fluorescent dye was electrosprayed with a stainless steel mesh screen placed in front of the MS inlet capillary acting as a gas-permeable imaging plate for fluorescence spectroscopy. Without use of the air amplifier no detectable FT-ICR signal was observed, as well as no detectable fluorescence on the screen upon imaging using a fluorescence scanner. When the air amplifier was turned ON while electrospraying the fluorescent dye, FT-ICR mass spectra with high signal to noise ratio were obtained with an average ion injection time of 21 milliseconds for an AGC target value of 5 × 105. Imaging of the screen using a fluorescence scanner produced a distinct spot of cross-sectional area ~33.5 mm2 in front of the MS inlet capillary. These experimental results provide direct evidence of aerodynamic focusing of electrosprayed droplets/ions enabled by an air amplifier, resulting in improved electrospray droplet/ion capture efficiency and reduced ion injection time. A second set of experiments was carried out to explore whether the air amplifier assists in desolvation. By electrospraying a mix of quaternary amines, ratios of increasingly hydrophobic molecules were obtained. Observation of the solvophobic effect associated with electrospray ionization resulted in a higher abundance of the hydrophobic molecule. This bias was eliminated when the air amplifier was turned ON and a response indicative of the respective component concentrations of the molecules in the bulk solution was observed. PMID:17855111

  13. Subcellular analysis by laser ablation electrospray ionization mass spectrometry

    DOEpatents

    Vertes, Akos; Stolee, Jessica A; Shrestha, Bindesh

    2014-12-02

    In various embodiments, a method of laser ablation electrospray ionization mass spectrometry (LAESI-MS) may generally comprise micro-dissecting a cell comprising at least one of a cell wall and a cell membrane to expose at least one subcellular component therein, ablating the at least one subcellular component by an infrared laser pulse to form an ablation plume, intercepting the ablation plume by an electrospray plume to form ions, and detecting the ions by mass spectrometry.

  14. Detection, characterization and identification of crucifer phytoalexins using high-performance liquid chromatography with diode array detection and electrospray ionization mass spectrometry.

    PubMed

    Pedras, M Soledade C; Adio, Adewale M; Suchy, Mojmir; Okinyo, Denis P O; Zheng, Qing-An; Jha, Mukund; Sarwar, Mohammed G

    2006-11-10

    We have analyzed 23 crucifer phytoalexins (e.g. brassinin, dioxibrassinin, cyclobrassinin, brassicanals A and C) by HPLC with diode array detection and electrospray ionization mass spectrometry (HPLC-DAD-ESI-MS) using both negative and positive ion modes. Positive ion mode ESI-MS appeared more sensitive than negative ion mode ESI-MS in detecting this group of compounds. A new HPLC separation method, new LC-MS and LC-MS(2) data and proposed fragmentation pathways, LC retention times, and UV spectra for selected compounds are reported.

  15. Separation and characterisation of five polar herbicides using countercurrent chromatography with detection by negative ion electrospray ionisation mass spectrometry.

    PubMed

    Kidwell, H; Jones, J J; Games, D E

    2001-01-01

    Five polar herbicides were separated and characterised using high-speed analytical countercurrent chromatography (HSACCC) in conjunction with online electrospray mass spectrometry (ESI-MS). The countercurrent chromatography used a standard isocratic biphasic solvent system of hexane/ethyl acetate/methanol/water in reverse phase to effect the separation of these five environmentally important compounds. The chromatograph was coupled to a triple quadrupole mass spectrometer via a standard electrospray liquid chromatography interface that was able to give mass spectra in negative ion mode of each compound. Limits of detection are reported for this series of compounds along with representative negative ion ESI-MS data and calibrations for the separation. Copyright 2001 John Wiley & Sons, Ltd.

  16. Laser electrospray mass spectrometry of adsorbed molecules at atmospheric pressure

    NASA Astrophysics Data System (ADS)

    Brady, John J.; Judge, Elizabeth J.; Simon, Kuriakose; Levis, Robert J.

    2010-02-01

    Atmospheric pressure mass analysis of solid phase biomolecules is performed using laser electrospray mass spectrometry (LEMS). A non-resonant femtosecond duration laser pulse vaporizes native samples at atmospheric pressure for subsequent electrospray ionization and transfer into a mass spectrometer. LEMS was used to detect a complex molecule (irinotecan HCl), a complex mixture (cold medicine formulation with active ingredients: acetaminophen, dextromethorphan HBr and doxylamine succinate), and a biological building block (deoxyguanosine) deposited on steel surfaces without a matrix molecule.

  17. Hands-on Electrospray Ionization-Mass Spectrometry for Upper-Level Undergraduate and Graduate Students

    ERIC Educational Resources Information Center

    Stock, Naomi L.; March, Raymond E.

    2014-01-01

    Electrospray ionization-mass spectrometry (ESI-MS) is a powerful technique for the detection, identification, and quantification of organic compounds. As mass spectrometers have become more user-friendly and affordable, many students--often with little experience in mass spectrometry--find themselves needing to incorporate mass spectrometry into…

  18. Ultra High-Resolution Electrospray Ionization/Ion Mobility Spectrometer System for In-Situ Detection of Organic Compounds

    NASA Technical Reports Server (NTRS)

    Kanik, I.; Beegle, L. W.; Hill, H. H.

    2001-01-01

    The potential of the high-resolution Electrospray Ionization/Ion Mobility Spectrometry (ESI/IMS) technique as analytical separation tool in analyzing bio-molecular mixtures in the search for the chemical signatures of life is demonstrated. Additional information is contained in the original extended abstract.

  19. Molecular Characterization of Brown Carbon (BrC) Chromophores in Secondary Organic Aerosol Generated From Photo-Oxidation of Toluene

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Peng; Liu, Jiumeng; Shilling, John E.

    Atmospheric Brown carbon (BrC) is a significant contributor to light absorption and climate forcing. However, little is known about a fundamental relationship between the chemical composition of BrC and its optical properties. In this work, light-absorbing secondary organic aerosol (SOA) was generated in the PNNL chamber from toluene photo-oxidation in the presence of NOx (Tol-SOA). Molecular structures of BrC components were examined using nanospray desorption electrospray ionization (nano-DESI) and liquid chromatography (LC) combined with UV/Vis spectroscopy and electrospray ionization (ESI) high-resolution mass spectrometry (HRMS). The chemical composition of BrC chromophores and the light absorption properties of toluene SOA (Tol-SOA) dependmore » strongly on the initial NOx concentration. Specifically, Tol-SOA generated under high-NOx conditions (defined here as initial NOx/toluene of 5/1) appears yellow and mass absorption coefficient of the bulk sample (MACbulk@365nm = 0.78 m2 g-1) is nearly 80 fold higher than that measured for the Tol-SOA sample generated under low-NOx conditions (NOx/toluene < 1/300). Fifteen compounds, most of which are nitrophenols, are identified as major BrC chromophores responsible for the enhanced light absorption of Tol-SOA material produced in the presence of NOx. The integrated absorbance of these fifteen chromophores accounts for 40-60% of the total light absorbance by Tol-SOA at wavelengths between 300 nm and 500 nm. The combination of tandem LC-UV/Vis-ESI/HRMS measurements provides an analytical platform for predictive understanding of light absorption properties by BrC and their relationship to the structure of individual chromophores. General trends in the UV/vis absorption by plausible isomers of the BrC chromophores were evaluated using theoretical chemistry calculations. The molecular-level understanding of BrC chemistry is helpful for better understanding the evolution and behavior of light absorbing aerosols in the atmosphere.« less

  20. Dietary isoflavone absorption, excretion, and metabolism in captive cheetahs (Acinonyx jubatus).

    PubMed

    Whitehouse-Tedd, Katherine M; Cave, Nicholas J; Ugarte, Claudia E; Waldron, Lucy A; Prasain, Jeevan K; Arabshahi, Alireza; Barnes, Stephen; Thomas, David G

    2011-12-01

    Dietary isoflavones, capable of influencing reproductive parameters in domestic cats (Felis catus), have been detected in commercial diets fed to captive cheetahs (Acinonyx jubatus). However, the absorptive and metabolic capacity of cheetahs towards isoflavones has not yet been studied. Experiments were designed to describe the plasma concentration-time curve, metabolite profile, and urinary and fecal excretion of genistein and daidzein in cheetahs following consumption of isoflavones. Four adult cheetahs were administered a single oral bolus of genistein and daidzein, and five juvenile cheetahs consuming a milk replacer formula found to contain isoflavones were also included. Urine was collected from all animals, and blood and feces were also collected from adult cheetahs following isoflavone exposure. Samples were analyzed for isoflavone metabolite concentration by liquid chromatography-electrospray ionization-multiple reaction ion monitoring mass spectrometry and high-performance liquid chromatography. Sulfate conjugates were the primary metabolites detected of both genistein and daidzein (60-80% of total isoflavones present) in the plasma and urine of cheetahs. A smaller proportion of daidzein was detected as conjugates in the urine of juvenile cheetahs, compared to adult cheetahs. Other metabolites included unconjugated genistein and daidzein, O-desmethylangolensin, and dihydrodaidzein, but not equol. Only 33% of the ingested genistein dose, and 9% of daidzein, was detected in plasma from adult cheetahs. However, of the ingested dose, 67% of genistein and 45% of daidzein were detected in the feces of adults. This study revealed that cheetahs appear efficient in their conjugation of absorbed dietary isoflavones and only a small fraction of ingested dose is absorbed. However, the capacity of the cheetah to conjugate genistein and daidzein with sulfate moieties appears lower than reported in the domestic cat. This may confer greater opportunity for biologic activity of isoflavones in the cheetah than would be predicted from findings in the domestic cat. However, further investigation is required.

  1. OVERVIEW OF A NEW EPA METHOD: DETERMINATION OF PERCHLORATE IN DRINKING WATER, GROUNDWATER AND HIGH SALINITY WATER BY ION CHROMATOGRAPHY, SUPPRESSED CONDUCTIVITY WITH ELECTROSPRAY IONIZATION MASS SPECTROMETRIC DETECTION

    EPA Science Inventory

    In this presentation the analytical instrumentation and procedures necessary to qualitatively and quantitatively determine low levels of perchlorate (ClO4-) in drinking waters using ion chromatography with electrolytic conductivity suppression, electrospray ionization mass spec...

  2. Separation and identification of neutral cereal lipids by normal phase high-performance liquid chromatography, using evaporative light-scattering and electrospray mass spectrometry for detection.

    PubMed

    Rocha, João M; Kalo, Paavo J; Ollilainen, Velimatti; Malcata, F Xavier

    2010-04-30

    A novel method was developed for the analysis of molecular species in neutral lipid classes, using separation by normal phase high-performance liquid chromatography, followed by detection by evaporative light-scattering and electrospray ionization tandem mass spectrometry. Monoacid standards, i.e. sterol esters, triacylglycerols, fatty acids, diacylglycerols, free sterols and monoacylglycerols, were separated to baseline on microbore 3 microm-silica gel columns. Complete or partial separation of molecular species in each lipid class permitted identification by automatic tandem mass spectrometry of ammonium adducts, produced via positive electrospray ionization. After optimization of the method, separation and identification of molecular species of various lipid classes was comprehensively tested by analysis of neutral lipids from the free lipid extract of maize flour. 2010 Elsevier B.V. All rights reserved.

  3. Derivatization reagents in liquid chromatography/electrospray ionization tandem mass spectrometry.

    PubMed

    Santa, Tomofumi

    2011-01-01

    Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds. 2010 John Wiley & Sons, Ltd.

  4. Rapid in situ detection of alkaloids in plant tissue under ambient conditions using desorption electrospray ionization.

    PubMed

    Talaty, Nari; Takáts, Zoltán; Cooks, R Graham

    2005-12-01

    Desorption electrospray ionization (DESI) mass spectrometry is applied to the in situ detection of alkaloids in the tissue of poison hemlock (Conium maculatum), jimsonweed (Datura stramonium) and deadly nightshade (Atropa belladonna). The experiment is carried out by electrospraying micro-droplets of solvent onto native or freshly-cut plant tissue surfaces. No sample preparation is required and the mass spectra are recorded under ambient conditions, in times of a few seconds. The impact of the sprayed droplets on the surface produces gaseous ions from organic compounds originally present in the plant tissue. The effects of operating parameters, including the electrospray high voltage, heated capillary temperature, the solvent infusion rate and the carrier gas pressure on analytical performance are evaluated and optimized. Different types of plant material are analyzed including seeds, stems, leaves, roots and flowers. All the previously reported alkaloids have been detected in C. maculatum, while fifteen out of nineteen known alkaloids for D. stramonium and the principal alkaloids of A. belladonna were also identified. All identifications were confirmed by tandem mass spectrometry. Results obtained show similar mass spectra, number of alkaloids, and signal intensities to those obtained when extraction and separation processes are performed prior to mass spectrometric analysis. Evidence is provided that DESI ionization occurs by both a gas-phase ionization process and by a droplet pick-up mechanism. Quantitative precision of DESI is compared with conventional electrospray ionization mass spectrometry (after sample workup) and the RSD values for the same set of 25 dicotyledonous C. maculatum seeds (one half of each seed analyzed by ESI and the other by DESI) are 9.8% and 5.2%, respectively.

  5. Improved detection limits for electrospray ionization on a magnetic sector mass spectrometer by using an array detector.

    PubMed

    Cody, R B; Tamura, J; Finch, J W; Musselman, B D

    1994-03-01

    Array detection was compared with point detection for solutions of hen egg-white lysozyme, equine myoglobin, and ubiquitin analyzed by electrospray ionization with a magnetic sector mass spectrometer. The detection limits for samples analyzed by using the array detector system were at least 10 times lower than could be achieved by using a point detector on the same mass spectrometer. The minimum detectable quantity of protein corresponded to a signal-to-background ratio of approximately 2∶1 for a 500 amol/μL solution of hen egg-white lysozyme. However, the ultimate practical sample concentrations appeared to be in the 10-100 fmol/μL range for the analysis of dilute solutions of relatively pure proteins or simple mixtures.

  6. Effect of phospholipid deposits on adhesion of bacteria to contact lenses.

    PubMed

    Babaei Omali, Negar; Proschogo, Nicholas; Zhu, Hua; Zhao, Zhenjun; Diec, Jennie; Borazjani, Roya; Willcox, Mark D P

    2012-01-01

    Protein and lipid deposits on contact lenses may contribute to clinical complications. This study examined the effect of phospholipids on the adhesion of bacteria to contact lenses. Worn balafilcon A (n = 11) and senofilcon A (n = 11) were collected after daily wear and phospholipids were extracted in chloroform:methanol. The amount of phospholipid was measured by electrospray ionization mass spectrometry. Unworn lenses soaked in phospholipids were exposed to Pseudomonas aeruginosa and Staphylococcus aureus. After 18 h incubation, the numbers of P. aeruginosa or S. aureus that adhered to the lenses were measured. Phospholipid was tested for possible effects on bacterial growth. A broad range of sphingomyelins (SM) and phosphatidylcholines (PC) were detected from both types of worn lenses. SM (16:0) (m/z 703) and PC (34:2) (m/z 758) were the major phospholipids detected in the lens extracts. Phospholipids did not alter the adhesion of any strain of P. aeruginosa or S. aureus (p > 0.05). Phospholipids (0.1 mg/mL) showed no effect on the growth of P. aeruginosa 6294 or S. aureus 031. Phospholipids adsorb/absorb to contact lenses during wear, however, the major types of phospholipids adsorbed to lenses do not alter bacterial adhesion or growth.

  7. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, Richard D.; Udseth, Harold R.; Barinaga, Charles J.

    1995-01-01

    An improvement to the system and method for analyzing molecular constituents of a composition sample that comprises improvements to an electrospray ionization source for interfacing to mass spectrometers and other detection devices. The improvement consists of establishing a unique electrical circuit pattern and nozzle configuration, a metallic coated and conical shaped capillary outlet, coupled with sizing of the capillary to obtain maximum sensitivity.

  8. Thin-layer chromatography and mass spectrometry coupled using proximal probe thermal desorption with electrospray or atmospheric pressure chemical ionization.

    PubMed

    Ovchinnikova, Olga S; Van Berkel, Gary J

    2010-06-30

    An atmospheric pressure proximal probe thermal desorption sampling method coupled with secondary ionization by electrospray or atmospheric pressure chemical ionization was demonstrated for the mass spectrometric analysis of a diverse set of compounds (dyestuffs, pharmaceuticals, explosives and pesticides) separated on various high-performance thin-layer chromatography plates. Line scans along or through development lanes on the plates were carried out by moving the plate relative to a stationary heated probe positioned close to or just touching the stationary phase surface. Vapors of the compounds thermally desorbed from the surface were drawn into the ionization region of a combined electrospray ionization/atmospheric pressure chemical ionization source where they merged with reagent ions and/or charged droplets from a corona discharge or an electrospray emitter and were ionized. The ionized components were then drawn through the atmospheric pressure sampling orifice into the vacuum region of a triple quadrupole mass spectrometer and detected using full scan, single ion monitoring, or selected reaction monitoring mode. Studies of variable parameters and performance metrics including the proximal probe temperature, gas flow rate into the ionization region, surface scan speed, read-out resolution, detection limits, and surface type are discussed.

  9. Fast profiling of anthocyanins in wine by desorption nano-electrospray ionization mass spectrometry.

    PubMed

    Hartmanova, Lucie; Ranc, Vaclav; Papouskova, Barbora; Bednar, Petr; Havlicek, Vladimir; Lemr, Karel

    2010-06-18

    Desorption electrospray ionization (DESI) mass spectrometry appears to be a useful technique applicable in different areas (e.g. analysis of pharmaceuticals, identification of biologically active compounds in tissues, imaging mass spectrometry). Its modification termed desorption nano-electrospray (nano-DESI) was tested for analysis of anthocyanins. Acidifying of samples and acidic spray liquid (methanol:water=75:25 with 0.2% HCOOH) were essential for obtaining good quality spectra. Profiles of main anthocyanins in wine samples, two vintages (2005 and 2007) of three cultivars (Alibernet, Neronet and Rubinet), were successfully acquired. They were in agreement with results of LC/MS experiments (anthocyanins isolated by solid phase extraction were separated by mu-HPLC with gradient elution and detected by ESI-MS). Nano-DESI-MS data also allowed to determine ratio of two cultivars (Neronet and Rubinet) in their mixture and to detect coloring of wine by tenturier or elderberry extract. Detection of main anthocyanins in slices of wine grape, chokeberries and elderberries or in a wine stain on cotton fabric is also presented. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  10. Detection, characterization and identification of phenolic acids in Danshen using high-performance liquid chromatography with diode array detection and electrospray ionization mass spectrometry.

    PubMed

    Liu, Ai-Hua; Guo, Hui; Ye, Min; Lin, Yan-Hua; Sun, Jiang-Hao; Xu, Man; Guo, De-An

    2007-08-17

    By using HPLC-diode array detection-electrospray ion trap tandem mass spectrometry (HPLC-DAD-ESI-MS(n)) in negative ion mode, we have analyzed the fragmentation pathways of 11 phenolic acids which were isolated from Danshen. Then the extract of Danshen was analyzed, and a total of 42 phenolic acids, including sixteen new minor constituents, were identified or tentatively identified for the first time. A new solid-phase extraction (SPE) method, new HPLC separation method, new liquid chromatography (LC)-MS and LC-MS(n) (n=3-5) data and proposed fragmentation pathways, LC retention time for phenolic acids are reported.

  11. Detection of over 100 selenium metabolites in selenized yeast by liquid chromatography electrospray time-of-flight mass spectrometry.

    PubMed

    Gilbert-López, Bienvenida; Dernovics, Mihaly; Moreno-González, David; Molina-Díaz, Antonio; García-Reyes, Juan F

    2017-08-15

    The characterization of the selenometabolome of Selenized(Se)-yeast, that is the fraction of water soluble low-molecular weight Se-metabolites produced in Se-yeast is of paramount interest to expand the knowledge on the composition of this food supplement. In this work, we have applied liquid chromatography electrospray time-of-flight mass spectrometry (LC-TOFMS) to search for Se-species from the low molecular weight range fraction of the selenized yeast used for food supplements. Prior to LC-TOFMS, sample treatment consisted of ultrasound assisted water extraction followed by size exclusion fractionation assisted with off-line inductively coupled plasma mass spectrometry detection of isotope 82 Se. The fraction corresponding to low-molecular weight species was subjected to LC-TOFMS using electrospray ionization in the positive ion mode. The detection of the suspected selenized species has been based on the information obtained from accurate mass measurements of both the protonated molecules and fragments from in-source CID fragmentation; along with the characteristic isotope pattern exhibited by the presence of Se. The approach enables the detection of 103 selenized species, most of them not previously reported, in the range from ca. 300-650Da. Besides the detection of selenium species, related sulphur derivate metabolites were detected based on the accurate mass shift due to the substitution of sulphur and selenium. Copyright © 2017. Published by Elsevier B.V.

  12. Tracking changes in the optical properties and molecular composition of dissolved organic matter during drinking water production.

    PubMed

    Lavonen, E E; Kothawala, D N; Tranvik, L J; Gonsior, M; Schmitt-Kopplin, P; Köhler, S J

    2015-11-15

    Absorbance, 3D fluorescence and ultrahigh resolution electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FT-ICR-MS) were used to explain patterns in the removal of chromophoric and fluorescent dissolved organic matter (CDOM and FDOM) at the molecular level during drinking water production at four large drinking water treatment plants in Sweden. When dissolved organic carbon (DOC) removal was low, shifts in the dissolved organic matter (DOM) composition could not be detected with commonly used DOC-normalized parameters (e.g. specific UV254 absorbance - SUVA), but was clearly observed by using differential absorbance and fluorescence or ESI-FT-ICR-MS. In addition, we took a novel approach by identifying how optical parameters were correlated to the elemental composition of DOM by using rank correlation to connect optical properties to chemical formulas assigned to mass peaks from FT-ICR-MS analyses. Coagulation treatment selectively removed FDOM at longer emission wavelengths (450-600 nm), which significantly correlated with chemical formulas containing oxidized carbon (average carbon oxidation state ≥ 0), low hydrogen to carbon ratios (H/C: average ± SD = 0.83 ± 0.13), and abundant oxygen-containing functional groups (O/C = 0.62 ± 0.10). Slow sand filtration was less efficient in removing DOM, yet selectively targeted FDOM at shorter emission wavelengths (between 300 and 450 nm), which commonly represents algal rather than terrestrial sources. This shorter wavelength FDOM correlated with chemical formulas containing reduced carbon (average carbon oxidation state ≤ 0), with relatively few carbon-carbon double bonds (H/C = 1.32 ± 0.16) and less oxygen per carbon (O/C = 0.43 ± 0.10) than those removed during coagulation. By coupling optical approaches with FT-ICR-MS to characterize DOM, we were for the first time able to confirm the molecular composition of absorbing and fluorescing DOM selectively targeted during drinking water treatment. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, R.D.; Udseth, H.R.; Barinaga, C.J.

    1995-06-13

    An improvement to the system and method is disclosed for analyzing molecular constituents of a composition sample that comprises improvements to an electrospray ionization source for interfacing to mass spectrometers and other detection devices. The improvement consists of establishing a unique electrical circuit pattern and nozzle configuration, a metallic coated and conical shaped capillary outlet, coupled with sizing of the capillary to obtain maximum sensitivity. 10 figs.

  14. Expressing urine from a gel disposable diaper for biomonitoring using phthalates as an example.

    PubMed

    Liu, Liangpo; Xia, Tongwei; Guo, Lihua; Cao, Lanyu; Zhao, Benhua; Zhang, Jie; Dong, Sijun; Shen, Heqing

    2012-11-01

    The urinary metabolites of phthalates are well-accepted exposure biomarkers for adults and children older than 6 years but are not commonly used for infants owing to non-convenient sampling. In the light of this situation, a novel sampling method based on monitoring the urine expressed from the gel diaper was developed. The urine was expressed from the gel absorbent after mixing the absorbent with CaCl(2) and then collected by a laboratory-made device; the urinary phthalate metabolites were extracted and cleaned using a solid-phase extraction (SPE) column and analyzed with high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry / mass spectrometry. To evaluate the method's feasibility, the following factors were investigated: the proportion of CaCl(2) to gel absorbent, the urination volume variation and the target compounds' deposition bias in the diaper, the matrix blank of the different diaper brands, the storage stabilities and the recoveries of creatinine and phthalate metabolites in the expressed urine. Mono-methyl phthalate, mono-ethyl phthalate, mono-butyl phthalate, mono-benzyl phthalate, mono-2-ethylhexyl phthalate and mono-2-ethyl-5-oxohexyl phthalate were involved. 70-80% of the urine can be expressed from the diaper, and the expressed spiking recoveries and the limit of detection of mono-phthalates ranged from 88.5-115% and 0.21-0.50 ng/ml. The method was applied to measure phthalate metabolites in 65 gel diaper samples from 15 infants, and the pilot data suggests the infants are commonly exposed to phthalates. In summary, the method for monitoring of infant exposure to phthalates is sound and validated, and the potential health effects from the vulnerable infants' exposure to phthalates should be concerned.

  15. Quantitative thin-layer chromatography/mass spectrometry analysis of caffeine using a surface sampling probe electrospray ionization tandem mass spectrometry system.

    PubMed

    Ford, Michael J; Deibel, Michael A; Tomkins, Bruce A; Van Berkel, Gary J

    2005-07-15

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 mum/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 muL) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by approximately 8% or more) than the literature values.

  16. Quantitative Caffeine Analysis Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, Michael J; Deibel, Michael A.; Tomkins, Bruce A

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methodsmore » determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.« less

  17. A comparison of the determination and speciation of inorganic arsenic using general HPLC methodology with UV, MS and MS/MS detection.

    PubMed

    Gilmartin, Gregory; Gingrich, Diane

    2018-04-15

    The determination and speciation of arsenic in natural resources such as drinking water and agricultural soils has been a growing concern in recent years due to its many toxicological effects [1-3]. To speciate and quantitate concentrations of <1 ppm of arsenic, typically an ion chromatograph (IC) interfaced to an inductively coupled plasma mass spectrometer (ICP-MS) is employed [4-9]. This methodology may be very robust and sensitive, but it is expensive and not as ubiquitous as high performance liquid chromatography (HPLC) with ultraviolet (UV) absorbance detection or electrospray ionization mass spectrometry (ESI-MS). Anion exchange chromatography is a well-documented means of speciating arsenite (As(III), As 2 O 3 ) and arsenate (As(V), AsO 4 ) using UV [10], conductivity [11], or ESI-MS detection [12,13]. This paper demonstrates the utilization of common liquid chromatographic instrumentation to speciate and determines inorganic Arsenic compounds using UV or MS via selected ion recording (SIR) or multiple reaction monitoring (MRM) detection. This paper describes the analysis of arsenite and arsenate samples prepared using both deionized and ground water. The limit of quantitation for the techniques described in this paper for samples spiked in ground water were 454 ppb (As(III)) and 562 ppb (As(V)) for UV detection, 45.4 ppb (As(III)) and 56.2 ppb (As(V)) for SIR detection, and 4.54 ppb (As(III)) and 5.62 ppb (As(V)) for MRM detection. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Development of "one-pot" method for multi-class compounds in porcine formula feed by multi-function impurity adsorption cleaning followed ultra-performance liquid chromatography-tandem mass spectrometry detection.

    PubMed

    Wang, Peilong; Wang, Xiao; Zhang, Wei; Su, Xiaoou

    2014-02-01

    A novel and efficient determination method for multi-class compounds including β-agonists, sedatives, nitro-imidazoles and aflatoxins in porcine formula feed based on a fast "one-pot" extraction/multifunction impurity adsorption (MFIA) clean-up procedure has been developed. 23 target analytes belonging to four different class compounds could be determined simultaneously in a single run. Conditions for "one-pot" extraction were studied in detail. Under the optimized conditions, the multi-class compounds in porcine formula feed samples were extracted and purified with methanol contained ammonia and absorbents by one step. The compounds in extracts were purified by using multi types of absorbent based on MFIA in one pot. The multi-walled carbon nanotubes were employed to improved clean-up efficiency. Shield BEH C18 column was used to separate 23 target analytes, followed by tandem mass spectrometry (MS/MS) detection using an electro-spray ionization source in positive mode. Recovery studies were done at three fortification levels. Overall average recoveries of target compounds in porcine formula feed at each levels were >51.6% based on matrix fortified calibration with coefficients of variation from 2.7% to 13.2% (n=6). The limit of determination (LOD) of these compounds in porcine formula feed sample matrix was <5.0 μg/kg. This method was successfully applied in screening and confirmation of target drugs in >30 porcine formula feed samples. It was demonstrated that the integration of the MFIA protocol with the MS/MS instrument could serve as a valuable strategy for rapid screening and reliable confirmatory analysis of multi-class compounds in real samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Method for Continuous Monitoring of Electrospray Ion Formation

    NASA Astrophysics Data System (ADS)

    Metzler, Guille; Crathern, Susan; Bachmann, Lorin; Fernández-Metzler, Carmen; King, Richard

    2017-10-01

    A method for continuously monitoring the performance of electrospray ionization without the addition of hardware or chemistry to the system is demonstrated. In the method, which we refer to as SprayDx, cluster ions with solvent vapor natively formed by electrospray are followed throughout the collection of liquid chromatography-selected reaction monitoring data. The cluster ion extracted ion chromatograms report on the consistency of the ion formation and detection system. The data collected by the SprayDx method resemble the data collected for postcolumn infusion of analyte. The response of the cluster ions monitored reports on changes in the physical parameters of the ion source such as voltage and gas flow. SprayDx is also observed to report on ion suppression in a fashion very similar to a postcolumn infusion of analyte. We anticipate the method finding utility as a continuous readout on the performance of electrospray and other atmospheric pressure ionization processes. [Figure not available: see fulltext.

  20. Sheath liquid interface for the coupling of normal-phase liquid chromatography with electrospray mass spectrometry and its application to the analysis of neoflavonoids.

    PubMed

    Charles, Laurence; Laure, Frédéric; Raharivelomanana, Phila; Bianchini, Jean-Pierre

    2005-01-01

    A novel interface that allows normal-phase liquid chromatography to be coupled with electrospray ionization (ESI) is reported. A make-up solution of 60 mM ammonium acetate in methanol, infused at a 5 microl min(-1) flow-rate at the tip of the electrospray probe, provides a sheath liquid which is poorly miscible with the chromatographic effluent, but promotes efficient ionization of the targeted analytes. Protonated molecules generated in the ESI source were subjected to tandem mass spectrometric experiments in a triple-quadrupole mass spectrometer. The main fragmentation reactions were characterized for each analyte and specific mass spectral transitions were used to acquire chromatographic data in the multiple reaction monitoring detection mode. Results obtained during optimization of the sheath liquid composition and flow-rate suggest that the electrospray process was mainly under the control of the make-up solution, and that it forms an external charged layer around a neutral chromatographic mobile phase core. This sheath liquid interface was implemented for the analysis of some neoflavonoid compounds and its performance was evaluated. Limits of detection were established for calophillolide, inophyllum B, inophyllum P and inophyllum C at 100, 25, 15 and 100 ng ml(-1), respectively.

  1. Protein-based emulsion electrosprayed micro- and submicroparticles for the encapsulation and stabilization of thermosensitive hydrophobic bioactives.

    PubMed

    Gómez-Mascaraque, Laura G; López-Rubio, Amparo

    2016-03-01

    This work shows the potential of emulsion electrospraying of proteins using food-grade emulsions for the microencapsulation and enhanced protection of a model thermosensitive hydrophobic bioactive. Specifically, gelatin, a whey protein concentrate (WPC) and a soy protein isolate (SPI) were compared as emulsion stabilizers and wall matrices for encapsulation of α-linolenic acid. In a preliminary stage, soy bean oil was used as the hydrophobic component for the implementation of the emulsion electrospraying process, investigating the effect of protein type and emulsion protocol used (i.e. with or without ultrasound treatment) on colloidal stability. This oil was then substituted by the ω-3 fatty acid and the emulsions were processed by electrospraying and spray-drying, comparing both techniques. While the latter resulted in massive bioactive degradation, electrospraying proved to be a suitable alternative, achieving microencapsulation efficiencies (MEE) of up to ∼70%. Although gelatin yielded low MEEs due to the need of employing acetic acid for its processing by electrospraying, SPI and WPC achieved MEEs over 60% for the non-sonicated emulsions. Moreover, the degradation of α-linolenic acid at 80°C was significantly delayed when encapsulated within both matrices. Whilst less than an 8% of its alkene groups were detected after 27h of thermal treatment for free α-linolenic acid, up to 43% and 67% still remained intact within the electrosprayed SPI and WPC capsules, respectively. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Forensic applications of desorption electrospray ionisation mass spectrometry (DESI-MS).

    PubMed

    Morelato, Marie; Beavis, Alison; Kirkbride, Paul; Roux, Claude

    2013-03-10

    Desorption electrospray ionisation mass spectrometry (DESI-MS) is an emerging analytical technique that enables in situ mass spectrometric analysis of specimens under ambient conditions. It has been successfully applied to a large range of forensically relevant materials. This review assesses and highlights forensic applications of DESI-MS including the analysis and detection of illicit drugs, explosives, chemical warfare agents, inks and documents, fingermarks, gunshot residues and drugs of abuse in urine and plasma specimens. The minimal specimen preparation required for analysis and the sensitivity of detection achieved offer great advantages, especially in the field of forensic science. Crown Copyright © 2013. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Quantitative Thin-Layer Chromatography/Mass Spectrometry Analysis of Caffeine Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, Michael J; Deibel, Michael A.; Tomkins, Bruce A

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methodsmore » determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.« less

  4. Light-Absorbing Brown Carbon Aerosol Constituents from Combustion of Indonesian Peat and Biomass.

    PubMed

    Budisulistiorini, Sri Hapsari; Riva, Matthieu; Williams, Michael; Chen, Jing; Itoh, Masayuki; Surratt, Jason D; Kuwata, Mikinori

    2017-04-18

    Light-absorbing brown carbon (BrC) constituents of organic aerosol (OA) have been shown to significantly absorb ultraviolet (UV) and visible light and thus impact radiative forcing. However, molecular identification of the BrC constituents is still limited. In this study, we characterize BrC constituents at the molecular level in (i) aerosols emitted by combustion of peat, fern/leaf, and charcoal from Indonesia and (ii) ambient aerosols collected in Singapore during the 2015 haze episode. Aerosols were analyzed using ultra performance liquid chromatography instrument interfaced to a diode array detector and electrospray ionization high-resolution quadrupole time-of-flight mass spectrometer operated in the negative ion mode. In the laboratory-generated aerosols, we identified 41 compounds that can potentially absorb near-UV and visible wavelengths, such as oxygenated-conjugated compounds, nitroaromatics, and S-containing compounds. The sum of BrC constituents in peat, fern/leaf, and charcoal burning aerosols are 16%, 35%, and 28% of the OA mass, respectively, giving an average contribution of 24%. On average, the BrC constituents account for 0.4% of the ambient OA mass; however, large uncertainties in mass closure remain because of the lack of authentic standards. This study highlights the potential of light-absorbing BrC OA constituents from peat, fern/leaf, and charcoal burning and their importance in the atmosphere.

  5. Electrospray-assisted ultraviolet aerodynamic particle sizer spectrometer for real-time characterization of bacterial particles.

    PubMed

    Jung, Jae Hee; Lee, Jung Eun; Hwang, Gi Byoung; Lee, Byung Uk; Lee, Seung Bok; Jurng, Jong Soo; Bae, Gwi Nam

    2010-01-15

    The ultraviolet aerodynamic particle sizer (UVAPS) spectrometer is a novel, commercially available aerosol counter for real-time, continuous monitoring of viable bioaerosols based on the fluorescence induced from living microorganisms. For aerosolization of liquid-based microorganisms, general aerosolization methods such as atomization or nebulization may not be adequate for an accurate and quantitative characterization of the microorganisms because of the formation of agglomerated particles. In such cases, biological electrospray techniques have an advantage because they generate nonagglomerated particles, attributable to the repulsive electrical forces among particles with unipolar charges. Biological electrosprays are quickly gaining potential for the detection and control of living organisms in applications ranging from mass spectrometry to developmental microbiology. In this study, we investigated the size distribution, total concentration, and fluorescence percentage of bacterial particles in a real-time manner by electrospray-assisted UVAPS. A suspension containing Escherichia coli as a test microorganism was sprayed in a steady cone-jet mode using a specially designed electrospray system with a point-to-orifice-plate configuration based on charge-reduced electrospray size spectrometry. With the electrospray process, 98% of the total E. coli particle number concentration had a size of <1 mum and the geometric mean diameter was 0.779 mum, as compared with the respective values of 78% and 0.907 mum after nebulization. The fractions of fluorescence responsive particles and of particles that contained viable organisms in culture were 12% and 7%, respectively, from the electrospray process and 34% and 24% from nebulization. These results demonstrate that (1) the presence of agglomerated particles can lead to markedly overestimated fluorescence and culturability percentages compared with the values obtained from nonagglomerated particles, and (2) electrospray-assisted UVAPS can provide more accurate and quantitative real-time characterization of liquid-based microorganisms, owing to the generation of nonagglomerated particles.

  6. Developing a Vacuum Electrospray Source To Implement Efficient Atmospheric Sampling for Miniature Ion Trap Mass Spectrometer.

    PubMed

    Yu, Quan; Zhang, Qian; Lu, Xinqiong; Qian, Xiang; Ni, Kai; Wang, Xiaohao

    2017-12-05

    The performance of a miniature mass spectrometer in atmospheric analysis is closely related to the design of its sampling system. In this study, a simplified vacuum electrospray ionization (VESI) source was developed based on a combination of several techniques, including the discontinuous atmospheric pressure interface, direct capillary sampling, and pneumatic-assisted electrospray. Pulsed air was used as a vital factor to facilitate the operation of electrospray ionization in the vacuum chamber. This VESI device can be used as an efficient atmospheric sampling interface when coupled with a miniature rectilinear ion trap (RIT) mass spectrometer. The developed VESI-RIT instrument enables regular ESI analysis of liquid, and its qualitative and quantitative capabilities have been characterized by using various solution samples. A limit of detection of 8 ppb could be attained for arginine in a methanol solution. In addition, extractive electrospray ionization of organic compounds can be implemented by using the same VESI device, as long as the gas analytes are injected with the pulsed auxiliary air. This methodology can extend the use of the proposed VESI technique to rapid and online analysis of gaseous and volatile samples.

  7. Simultaneous determination of osthole, bergapten and isopimpinellin in rat plasma and tissues by liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Jing; Ma, Bo; Zhang, Qi; Yang, Xiaojing; Sun, Jingjing; Tang, Bowen; Cui, Guangbo; Yao, Di; Liu, Lei; Gu, Guiying; Zhu, Jianwei; Wei, Ping; Ouyang, Pingkai

    2014-11-01

    A highly selective and sensitive method for simultaneous quantitation of osthole, bergapten and isopimpinellin in rat plasma and tissues was developed by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). After liquid-liquid extraction of samples with methyl tert-butyl ether, the analytes and dextrorphan (internal standard, IS) were separated by a Hypersil GOLD AQ C18 column with gradient elution of acetonitrile and water containing 0.5‰ formic acid. Three determinands were detected using an electrospray ionization (ESI) tandem mass spectrometry in the multiple reaction monitoring (MRM) modes with positive electrospray ionization. Calibration curves were recovered over the concentration ranges of 1-200 ng/ml, 1-500 ng/ml, 0.25-200 ng/ml for osthole, bergapten and isopimpinellin in plasma; 1-100 ng/ml, 1-500 ng/ml, 0.5-100 ng/ml for osthole, bergapten and isopimpinellin in tissues, respectively. The intra-day precision (R.S.D.) was within 13.90% and the intra-day accuracy (R.E.) was within -6.27 to 6.84% in all biological matrixes. The inter-day precision (R.S.D.) was less than 13.66% and the inter-day accuracy (R.E.) was within -10.64 to 13.04%. Then the method was successfully applied to investigate plasma pharmacokinetic study and tissue distribution of osthole, bergapten and isopimpinellin in rats after oral administration of Fructus Cnidii extraction, especially for testis/uterus tissue distribution. The results demonstrated that osthole, bergapten and isopimpinellin were absorbed and eliminated rapidly with wide distributions in rats. Distribution data of these three bioactive components in testis/uterus tissues could offer useful information for the further preclinical and clinical studies of Fructus Cnidii in the treatment of genital system disease. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Simultaneous determination of carisoprodol and acetaminophen in an attempted suicide by liquid chromatography-mass spectrometry with positive electrospray ionization.

    PubMed

    Matsumoto, Tomohiro; Sano, Toshiyuki; Matsuoka, Toshiyasu; Aoki, Minoru; Maeno, Yoshitaka; Nagao, Masataka

    2003-03-01

    An adult female ingested a considerable quantity of carisoprodol/acetaminophen tablets, which are not commercially available in Japan, in an attempt to commit suicide. Generally, because of lack of the appreciable ultraviolet absorbance or fluorescence, carisoprodol and its major metabolite meprobamate are determined by gas chromatography or gas chromatography-mass spectrometry. Complicated derivatization is, however, necessary to that methodology. Thus, we investigated the derivatization-free, highly sensitive, and simultaneous determination of carisoprodol, meprobamate, and acetaminophen by means of liquid chromatography-mass spectrometry (LC-MS) with positive electrospray ionization. A semi-micro ODS column was used. Ammonium acetate solution (10mM) and acetonitrile were used as mobile phase at a flow rate of 150 microL/min using gradient elution. MS parameters were as follows: capillary voltage, 3.5 kV; cone voltage, +30 V; extractor voltage, 5 kV; and ion source temperature, 100 degrees C. Urine samples pretreated by Oasis HLB cartridge, or plasma samples deproteinized by adding ice-cold acetonitrile were analyzed by LC-MS. The limits of quantitation for each compound were as follows: 0.50 ng/mL for carisoprodol; 10 ng/mL for acetaminophen; and 1.0 ng/mL for meprobamate. In the present case, carisoprodol and acetaminophen were the only drugs detected. Meprobamate was also found as the metabolite of carisoprodol in both urine and plasma. The plasma levels of carisoprodol, acetaminophen, and meprobamate on arrival were 29.5, 245, and 46.7 microg/mL, respectively. These levels were extremely high compared with therapeutic plasma concentrations. Despite the high plasma concentrations of these drugs, which correspond to fatal levels, the patient survived.

  9. Dynamic calibration approach for determining catechins and gallic acid in green tea using LC-ESI/MS.

    PubMed

    Bedner, Mary; Duewer, David L

    2011-08-15

    Catechins and gallic acid are antioxidant constituents of Camellia sinensis, or green tea. Liquid chromatography with both ultraviolet (UV) absorbance and electrospray ionization mass spectrometric (ESI/MS) detection was used to determine catechins and gallic acid in three green tea matrix materials that are commonly used as dietary supplements. The results from both detection modes were evaluated with 14 quantitation models, all of which were based on the analyte response relative to an internal standard. Half of the models were static, where quantitation was achieved with calibration factors that were constant over an analysis set. The other half were dynamic, with calibration factors calculated from interpolated response factor data at each time a sample was injected to correct for potential variations in analyte response over time. For all analytes, the relatively nonselective UV responses were found to be very stable over time and independent of the calibrant concentration; comparable results with low variability were obtained regardless of the quantitation model used. Conversely, the highly selective MS responses were found to vary both with time and as a function of the calibrant concentration. A dynamic quantitation model based on polynomial data-fitting was used to reduce the variability in the quantitative results using the MS data.

  10. Determination of macrolide antibiotics in chicken tissues by liquid chromatography-electrospray mass spectrometry

    NASA Astrophysics Data System (ADS)

    Salikin, Jamilah; Abdullah, Aminah

    2013-11-01

    A methodusingliquid chromatography-electrospray mass spectrometry (LC-(ESI)MS) for the simultaneous determination of three macrolides (tylosin, spiramycin and tilmicosin) in poultry muscle has been developed. The drugs were extracted with EDTA McIlvaine buffer, filter through celite 545 and the extracts were cleaned up by SPE Oasis HLB cartridge. Separation was carried out in end-capped silica-based C18 column and mobile phases containing trifluoroacetic acid-acetonitrile with a binary gradient system at a flow rate 0.5 ml/min. Detection was performed by single mass spectrometry with electrospray ionization in the positive mode. Several parameters affecting the mass spectra were studied. Chicken samples from the market were analyzed to check the residue of macrolide antibiotics.

  11. Assessment of Reproducibility of Laser Electrospray Mass Spectrometry using Electrospray Deposition of Analyte

    NASA Astrophysics Data System (ADS)

    Sistani, Habiballah; Karki, Santosh; Archer, Jieutonne J.; Shi, Fengjian; Levis, Robert J.

    2017-05-01

    A nonresonant, femtosecond (fs) laser is employed to desorb samples of Victoria blue deposited on stainless steel or indium tin oxide (ITO) slides using either electrospray deposition (ESD) or dried droplet deposition. The use of ESD resulted in uniform films of Victoria blue whereas the dried droplet method resulted in the formation of a ring pattern of the dye. Laser electrospray mass spectrometry (LEMS) measurements of the ESD-prepared films on either substrate were similar and revealed lower average relative standard deviations for measurements within-film (20.9%) and between-films (8.7%) in comparison to dried droplet (75.5% and 40.2%, respectively). The mass spectral response for ESD samples on both substrates was linear (R2 > 0.99), enabling quantitative measurements over the selected range of 7.0 × 10-11 to 2.8 × 10-9 mol, as opposed to the dried droplet samples where quantitation was not possible (R2 = 0.56). The limit of detection was measured to be 210 fmol.

  12. Beyond Naphthenic Acids: Environmental Screening of Water from Natural Sources and the Athabasca Oil Sands Industry Using Atmospheric Pressure Photoionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry.

    PubMed

    Barrow, Mark P; Peru, Kerry M; Fahlman, Brian; Hewitt, L Mark; Frank, Richard A; Headley, John V

    2015-09-01

    There is a growing need for environmental screening of natural waters in the Athabasca region of Alberta, Canada, particularly in the differentiation between anthropogenic and naturally-derived organic compounds associated with weathered bitumen deposits. Previous research has focused primarily upon characterization of naphthenic acids in water samples by negative-ion electrospray ionization methods. Atmospheric pressure photoionization is a much less widely used ionization method, but one that affords the possibility of observing low polarity compounds that cannot be readily observed by electrospray ionization. This study describes the first usage of atmospheric pressure photoionization Fourier transform ion cyclotron resonance mass spectrometry (in both positive-ion and negative-ion modes) to characterize and compare extracts of oil sands process water, river water, and groundwater samples from areas associated with oil sands mining activities. When comparing mass spectra previously obtained by electrospray ionization and data acquired by atmospheric pressure photoionization, there can be a doubling of the number of components detected. In addition to polar compounds that have previously been observed, low-polarity, sulfur-containing compounds and hydrocarbons that do not incorporate a heteroatom were detected. These latter components, which are not amenable to electrospray ionization, have potential for screening efforts within monitoring programs of the oil sands.

  13. A UPLC-MS/MS method for qualification of quercetin-3-O-β-D-glucopyranoside-(4→1)-α-L-rhamnoside in rat plasma and application to pharmacokinetic studies.

    PubMed

    Yao, Xin; Zhou, Guisheng; Tang, Yuping; Li, Zhenhao; Su, Shulan; Qian, Dawei; Duan, Jin-Ao

    2013-03-07

    A sensitive and accurate ultra-performance liquid chromatography coupled with triple quadrupole mass (UPLC-MS/MS) method was developed for the determination of quercetin-3-O-β-D-glucopyranoside-(4→1)-α-L-rhamnoside (QGR) in rat plasma using rutin as internal standard. Chromatographic separation was achieved on a Acquity BEH C18 column (100 mm × 2.1 mm, 1.7 μm) with a gradient elution of acetonitrile and 0.10% formic acid (v/v) at a flow rate of 0.4 mL/min. QGR and rutin were detected using electrospray negative ionization mass spectrometry in the multiple reaction monitoring (MRM) mode. The method demonstrated good linearity and did not show any endogenous interference with the QGR and rutin peaks. This method was successfully applied to a pharmacokinetic study of QGR in rats after intravenous (20 mg/kg) and oral (40 mg/kg) administration, and the results showed that the compound was poorly absorbed, with an absolute bioavailability of approximately 3.41%.

  14. Pharmacokinetics and Tissue Distribution Study of Chlorogenic Acid from Lonicerae Japonicae Flos Following Oral Administrations in Rats

    PubMed Central

    Zhou, Yulu; Zhou, Ting; Pei, Qi; Liu, Shikun; Yuan, Hong

    2014-01-01

    Chlorogenic acid (ChA) is proposed as the major bioactive compounds of Lonicerae Japonicae Flos (LJF). Forty-two Wistar rats were randomly divided into seven groups to investigate the pharmacokinetics and tissue distribution of ChA, via oral administration of LJF extract, using ibuprofen as internal standard, employing a high performance liquid chromatography in conjunction with tandem mass spectrometry. Analytes were extracted from plasma samples and tissue homogenate by liquid–liquid extraction with acetonitrile, separated on a C 18 column by linear gradient elution, and detected by electrospray ionization mass spectrometry in negative selected multiple reaction monitoring mode. Our results successfully demonstrate that the method has satisfactory selectivity, linearity, extraction recovery, matrix effect, precision, accuracy, and stability. Using noncompartment model to study pharmacokinetics, profile revealed that ChA was rapidly absorbed and eliminated. Tissue study indicated that the highest level was observed in liver, followed by kidney, lung, heart, and spleen. In conclusion, this method was suitable for the study on pharmacokinetics and tissue distribution of ChA after oral administration. PMID:25140190

  15. Rapid quantification of iodopropynyl butylcarbamate as the preservative in cosmetic formulations using high-performance liquid chromatography-electrospray mass spectrometry.

    PubMed

    Frauen, M; Steinhart, H; Rapp, C; Hintze, U

    2001-07-01

    A simple, rapid and reproducible method for identification and quantification of iodopropynyl butylcarbamate (IPBC) in different cosmetic formulations is presented. The determination was carried out using a high-performance liquid chromatography (HPLC) procedure on a reversed phase column coupled to a single quadrupole mass spectrometer (MS) via an electrospray ionization (ESI) interface. Detection was performed in the positive selected ion-monitoring mode. In methanol/water extracts from different cosmetic formulations a detection limit between 50 and 100 ng/g could be achieved. A routine analytical procedure could be set up with good quantification reliability (relative standard deviation between 0.9 and 2.9%).

  16. Depth profiling of inks in authentic and counterfeit banknotes by electrospray laser desorption ionization/mass spectrometry.

    PubMed

    Kao, Yi-Ying; Cheng, Sy-Chyi; Cheng, Chu-Nian; Shiea, Jentaie

    2016-01-01

    Electrospray laser desorption ionization is an ambient ionization technique that generates neutrals via laser desorption and ionizes those neutrals in an electrospray plume and was utilized to characterize inks in different layers of copy paper and banknotes of various currencies. Depth profiling of inks was performed on overlapping color bands on copy paper by repeatedly scanning the line with a pulsed laser beam operated at a fixed energy. The molecules in the ink on a banknote were desorbed by irradiating the banknote surface with a laser beam operated at different energies, with results indicating that different ions were detected at different depths. The analysis of authentic $US100, $100 RMB and $1000 NTD banknotes indicated that ions detected in 'color-shifting' and 'typography' regions were significantly different. Additionally, the abundances of some ions dramatically changed with the depth of the aforementioned regions. This approach was used to distinguish authentic $1000 NTD banknotes from counterfeits. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Ultra trace determination of 31 pesticides in water samples by direct injection-rapid resolution liquid chromatography-electrospray tandem mass spectrometry.

    PubMed

    Díaz, Laura; Llorca-Pórcel, Julio; Valor, Ignacio

    2008-08-22

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for the detection of pesticides in tap and treated wastewater was developed and validated according to the ISO/IEC 17025:1999. Key features of this method include direct injection of 100 microL of sample, an 11 min separation by means of a rapid resolution liquid chromatography system with a 4.6 mm x 50 mm, 1.8 microm particle size reverse phase column and detection by electrospray ionization (ESI) MS-MS. The limits of detection were below 15 ng L(-1) and correlation coefficients for the calibration curves in the range of 30-2000 ng L(-1) were higher than 0.99. Precision was always below 20% and accuracy was confirmed by external evaluation. The main advantages of this method are direct injection of sample without preparative procedures and low limits of detection that fulfill the requirements established by the current European regulations governing pesticide detection.

  18. Low-molecular weight protein profiling of genetically modified maize using fast liquid chromatography electrospray ionization and time-of-flight mass spectrometry.

    PubMed

    Koc, Anna; Cañuelo, Ana; Garcia-Reyes, Juan F; Molina-Diaz, Antonio; Trojanowicz, Marek

    2012-06-01

    In this work, the use of liquid chromatography coupled to electrospray time-of-flight mass spectrometry (LC-TOFMS) has been evaluated for the profiling of relatively low-molecular weight protein species in both genetically modified (GM) and non-GM maize. The proposed approach consisted of a straightforward sample fractionation with different water and ethanol-based buffer solutions followed by separation and detection of the protein species using liquid chromatography with a small particle size (1.8 μm) C(18) column and electrospray-time-of-flight mass spectrometry detection in the positive ionization mode. The fractionation of maize reference material containing different content of transgenic material (from 0 to 5% GM) led to five different fractions (albumins, globulins, zeins, zein-like glutelins, and glutelins), all of them containing different protein species (from 2 to 52 different species in each fraction). Some relevant differences in the quantity and types of protein species were observed in the different fractions of the reference material (with different GM contents) tested, thus revealing the potential use of the proposed approach for fast protein profiling and to detect tentative GMO markers in maize. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Simultaneous determination of carboprost methylate and its active metabolite carboprost in dog plasma by liquid chromatography-tandem mass spectrometry with positive/negative ion-switching electrospray ionization and its application to a pharmacokinetic study.

    PubMed

    Yin, Lei; Meng, Xiangjun; Zhou, Xiaotong; Zhang, Tinglan; Sun, Heping; Yang, Zhichao; Yang, Bo; Xiao, Ning; Fawcett, J Paul; Yang, Yan; Gu, Jingkai

    2015-08-15

    A liquid chromatography-tandem mass spectrometric (LC-MS/MS) method using positive/negative electrospray ionization (ESI) switching for the simultaneous quantitation of carboprost methylate and carboprost in dog plasma has been developed and validated. After screening, the esterase inhibitor, dichlorvos was added to the whole blood at a ratio of 1:99 (v/v) to stabilize carboprost methylate during blood collection, sample storage and LLE. Indomethacin was added to plasma to inhibit prostaglandins synthesis after sampling. After liquid-liquid extraction of 500μL plasma with ethyl ether-dichloromethane (75:25, v/v), analytes and internal standard (IS), alprostadil-d4, were chromatographed on a CAPCELL PAK Phenyl column (150×2.0mm, 5μm) using acetonitrile-5mM ammonium acetate as mobile phase. Carboprost methylate was detected by positive ion electrospray ionization followed by multiple reaction monitoring (MRM) of the transition at m/z 400.5→329.3; the carboprost and IS were detected by negative ion electrospray ionization followed by MRM of the transitions at m/z 367.2→323.2, and 357.1→321.2, respectively. The method was linear for both analytes in the concentration range 0.05-30ng/mL with intra- and inter-day precisions (as relative standard deviation) of ≤6.75% and accuracy (as relative error) of ≤7.21% and limit of detection (LOD) values were 10 and 20pg/mL, respectively. The method was successfully applied to a pharmacokinetic study of the analytes in beagle dogs after intravaginal administration of a suppository containing 0.5mg carboprost methylate. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Characterisation of soy isoflavones and screening for novel malonyl glycosides using high-performance liquid chromatography-electrospray ionisation-mass spectrometry.

    PubMed

    Gu, L; Gu, W

    2001-01-01

    HPLC combined with electrospray ionisation (ESI)-MS and photodiode array detection has been employed to study the isoflavone components of soy. All of the known soy isoflavones separated by HPLC were identified and characterised, and three novel isoflavones were detected and screened out. These minor isoflavones were deduced to be isomers of 6"-O-malonyl isoflavone glycosides, based on the ESI-MS and UV data, in which the malonyl group is attached at a position other than the 6" position of the glycosyl moiety of the molecule. These novel malonyl glycosides are as thermally labile as the 6"-O-malonyl glycosides, being converted into known isoflavone glycosides after heating in aqueous ethanol. The advantages of HPLC-ESI-MS in detection of novel isoflavones from plant extracts are reviewed.

  1. Ion current detector for high pressure ion sources for monitoring separations

    DOEpatents

    Smith, R.D.; Wahl, J.H.; Hofstadler, S.A.

    1996-08-13

    The present invention relates generally to any application involving the monitoring of signal arising from ions produced by electrospray or other high pressure (>100 torr) ion sources. The present invention relates specifically to an apparatus and method for the detection of ions emitted from a capillary electrophoresis (CE) system, liquid chromatography, or other small-scale separation methods. And further, the invention provides a very simple diagnostic as to the quality of the separation and the operation of an electrospray source. 7 figs.

  2. Ion current detector for high pressure ion sources for monitoring separations

    DOEpatents

    Smith, Richard D.; Wahl, Jon H.; Hofstadler, Steven A.

    1996-01-01

    The present invention relates generally to any application involving the monitoring of signal arising from ions produced by electrospray or other high pressure (>100 torr) ion sources. The present invention relates specifically to an apparatus and method for the detection of ions emitted from a capillary electrophoresis (CE) system, liquid chromatography, or other small-scale separation methods. And further, the invention provides a very simple diagnostic as to the quality of the separation and the operation of an electrospray source.

  3. Speciation of Selenium in Selenium-Enriched Sunflower Oil by High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry/Electrospray-Orbitrap Tandem Mass Spectrometry.

    PubMed

    Bierla, Katarzyna; Flis-Borsuk, Anna; Suchocki, Piotr; Szpunar, Joanna; Lobinski, Ryszard

    2016-06-22

    The reaction of sunflower oil with selenite produces a complex mixture of selenitriglycerides with antioxidant and anticancer properties. To obtain insight into the identity and characteristics of the species formed, an analytical approach based on the combination of high-performance liquid chromatography (HPLC) with (78)Se-specific selenium detection by inductively coupled plasma mass spectrometry (ICP MS) and high-resolution (100 000), high mass accuracy (<1 ppm) molecule-specific detection by electrospray-Orbitrap MS(3) was developed. For the first time, a non-aqueous mobile phase gradient was used in reversed-phase HPLC-ICP MS for the separation of a complex mixture of selenospecies and a mathematical correction of the background signal was developed. The identical chromatographic conditions served for the sample introduction into electrospray MS. Two types of samples were analyzed: sunflower oil dissolved in isopropanol and methanol extract of the oil containing 65% selenium. HPLC-ICP MS showed 14 peaks, 11 of which could also be detected in the methanol extract. Isotopic patterns corresponding to molecules with one or two selenium atoms could be attributed by Orbitrap MS at the retention times corresponding to the HPLC-ICP MS peak apexes. Structural data for these species were acquired by MS(2) and MS(3) fragmentation of protonated or sodiated ions using high-energy collisional dissociation (HCD). A total of 11 selenium-containing triglycerol derivatives resulting from the oxidation of one or two double bonds of linoleic acid and analogous derivatives of glycerol-mixed linoleate(s)/oleinate(s) have been identified for the first time. The presence of these species was confirmed by the targeted analysis in the total oil isopropanol solution. Their identification corroborated the predicted elution order in reversed-phase chromatography: LLL (glycerol trilinoleate), LLO (glycerol dilinoleate-oleinate), LOO (glycerol linoleate-dioleinate), OOO (glycerol trioleinate), of which the extrapolation allowed for the prediction of the identity [glycerol dioleinate-stearate (OOS) and glycerol oleinate-distearate (OSS)] of the nonpolar species detected by ICP MS in the oil but not detected by electrospray MS.

  4. Detection of chlorinated and brominated byproducts of drinking water disinfection using electrospray ionization-high-field asymmetric waveform ion mobility spectrometry-mass spectrometry.

    PubMed

    Ells, B; Barnett, D A; Froese, K; Purves, R W; Hrudey, S; Guevremont, R

    1999-10-15

    The lower limit of detection for low molecular weight polar and ionic analytes using electrospray ionization-mass spectrometry (ESI-MS) is often severely compromised by an intense background that obscures ions of trace components in solution. Recently, a new technique, referred to as high-field asymmetric waveform ion mobility spectrometry (FAIMS), has been shown to separate gas-phase ions at atmospheric pressure and room temperature. A FAIMS instrument is an ion filter that may be tuned, by control of electrical voltages, to continuously transmit selected ions from a complex mixture. This capability offers significant advantages when FAIMS is coupled with ESI, a source that generates a wide variety of ions, including solvent clusters and salt adducts. In this report, the tandem arrangement of ESI-FAIMS-MS is used for the analysis of haloacetic acids, a class of disinfection byproducts regulated by the US EPA. FAIMS is shown to effectively discriminate against background ions resulting from the electrospray of tap water solutions containing the haloacetic acids. Consequently, mass spectra are simplified, the selectivity of the method is improved, and the limits of detection are lowered compared with conventional ESI-MS. The detection limits of ESI-FAIMS-MS for six haloacetic acids ranged between 0.5 and 4 ng/mL in 9:1 methanol/tap water (5 and 40 ng/mL in the original tap water samples) with no preconcentration, derivatization, or chromatographic separation prior to analysis.

  5. Comprehensive Biothreat Cluster Identification by PCR/Electrospray-Ionization Mass Spectrometry

    PubMed Central

    Sampath, Rangarajan; Mulholland, Niveen; Blyn, Lawrence B.; Massire, Christian; Whitehouse, Chris A.; Waybright, Nicole; Harter, Courtney; Bogan, Joseph; Miranda, Mary Sue; Smith, David; Baldwin, Carson; Wolcott, Mark; Norwood, David; Kreft, Rachael; Frinder, Mark; Lovari, Robert; Yasuda, Irene; Matthews, Heather; Toleno, Donna; Housley, Roberta; Duncan, David; Li, Feng; Warren, Robin; Eshoo, Mark W.; Hall, Thomas A.; Hofstadler, Steven A.; Ecker, David J.

    2012-01-01

    Technology for comprehensive identification of biothreats in environmental and clinical specimens is needed to protect citizens in the case of a biological attack. This is a challenge because there are dozens of bacterial and viral species that might be used in a biological attack and many have closely related near-neighbor organisms that are harmless. The biothreat agent, along with its near neighbors, can be thought of as a biothreat cluster or a biocluster for short. The ability to comprehensively detect the important biothreat clusters with resolution sufficient to distinguish the near neighbors with an extremely low false positive rate is required. A technological solution to this problem can be achieved by coupling biothreat group-specific PCR with electrospray ionization mass spectrometry (PCR/ESI-MS). The biothreat assay described here detects ten bacterial and four viral biothreat clusters on the NIAID priority pathogen and HHS/USDA select agent lists. Detection of each of the biothreat clusters was validated by analysis of a broad collection of biothreat organisms and near neighbors prepared by spiking biothreat nucleic acids into nucleic acids extracted from filtered environmental air. Analytical experiments were carried out to determine breadth of coverage, limits of detection, linearity, sensitivity, and specificity. Further, the assay breadth was demonstrated by testing a diverse collection of organisms from each biothreat cluster. The biothreat assay as configured was able to detect all the target organism clusters and did not misidentify any of the near-neighbor organisms as threats. Coupling biothreat cluster-specific PCR to electrospray ionization mass spectrometry simultaneously provides the breadth of coverage, discrimination of near neighbors, and an extremely low false positive rate due to the requirement that an amplicon with a precise base composition of a biothreat agent be detected by mass spectrometry. PMID:22768032

  6. Impact desolvation of electrosprayed microdroplets--a new ionization method for mass spectrometry of large biomolecules.

    PubMed

    Aksyonov, S A; Williams, P

    2001-01-01

    Impact desolvation of electrosprayed microdroplets (IDEM) is a new method for producing gas-phase ions of large biomolecules. Analytes are dissolved in an electrolyte solution which is electrosprayed in vacuum, producing highly charged micron and sub-micron sized droplets (microdroplets). These microdroplets are accelerated through potential differences approximately 5 - 10 kV to velocities of several km/s and allowed to impact a target surface. The energetic impacts vaporize the droplets and release desolvated gas-phase ions of the analyte molecules. Oligonucleotides (2- to 12-mer) and peptides (bradykinin, neurotensin) yield singly and doubly charged molecular ions with no detectable fragmentation. Because the extent of multiple charging is significantly less than in atmospheric pressure electrospray ionization, and the method produces ions largely free of adducts from solutions of high ionic strength, IDEM has some promise as a method for coupling to liquid chromatographic techniques and for mixture analysis. Ions are produced in vacuum at a flat equipotential surface, potentially allowing efficient ion extraction. Copyright 2001 John Wiley & Sons, Ltd.

  7. Toward single-cell analysis by plume collimation in laser ablation electrospray ionization mass spectrometry.

    PubMed

    Stolee, Jessica A; Vertes, Akos

    2013-04-02

    Ambient ionization methods for mass spectrometry have enabled the in situ and in vivo analysis of biological tissues and cells. When an etched optical fiber is used to deliver laser energy to a sample in laser ablation electrospray ionization (LAESI) mass spectrometry, the analysis of large single cells becomes possible. However, because in this arrangement the ablation plume expands in three dimensions, only a small portion of it is ionized by the electrospray. Here we show that sample ablation within a capillary helps to confine the radial expansion of the plume. Plume collimation, due to the altered expansion dynamics, leads to greater interaction with the electrospray plume resulting in increased ionization efficiency, reduced limit of detection (by a factor of ~13, reaching 600 amol for verapamil), and extended dynamic range (6 orders of magnitude) compared to conventional LAESI. This enhanced sensitivity enables the analysis of a range of metabolites from small cell populations and single cells in the ambient environment. This technique has the potential to be integrated with flow cytometry for high-throughput metabolite analysis of sorted cells.

  8. Identification of multiple constituents in the traditional Chinese medicine formula Zhi-zi-chi decoction and rat plasma after oral administration by liquid chromatography coupled to quadrupole time-of-flight tandem mass spectrometry.

    PubMed

    Zhao, Xu; Long, Zhimin; Dai, Jinna; Bi, Kaishun; Chen, Xiaohui

    2012-10-30

    Liquid chromatography (LC) coupled to positive electrospray ionization (ESI) tandem mass spectrometry (MS/MS) employing a time-of-flight tandem mass spectrometer was established to identify multi-components of Zhi-zi-chi decoction, a traditional Chinese medicine formula, and the constituents in rat plasma after oral administration of Zhi-zi-chi decoction. The LC separation was achieved on a C(18) column. The mobile phase consisted of acetonitrile/0.2% formic acid with gradient program. The quadrupole time-of-flight (Q-TOF) mass spectrometer was operated in the positive ion mode with an electrospray ionization source (ESI+). The capillary voltage of the ion source was set at 4500 V and the capillary exit was 90 V. The nebulizer pressure was maintained at 1.2 bar. Hexapole radio frequencies 1 and 2 were set to 200 Vpp and 250 Vpp, respectively. A total 47 compounds in the Zhi-zi-chi decoction and 24 constituents in rat plasma after oral administration of Zhi-zi-chi decoction were identified. Of the 47 detected compounds in the Zhi-zi-chi decoction, 15 were identified by comparing the retention time and MS data with that of reference compounds and the rest were identified by MS analysis and retrieving the reference literature. Of the identified 24 compounds in rat plasma, 19 were the original form of the compounds absorbed from the 47 detected compounds, and the other five were the metabolites of the compounds existing in the Zhi-zi-chi decoction. A fast and sensitive LC/Q-TOF MS method has been developed and successfully utilized to screen the active ingredients of a Chinese medical formula, Zhi-zi-chi decoction, for the first time. The results indicated that the 24 compounds identified in rat plasma were the potential active ingredients of Zhi-zi-chi decoction, which provided helpful chemical information for further pharmacology and active mechanism research on Zhi-zi-chi decoction and other traditional Chinese medicines. Copyright © 2012 John Wiley & Sons, Ltd.

  9. Detection of creatinine in exhaled breath of humans with chronic kidney disease by extractive electrospray ionization mass spectrometry.

    PubMed

    Zeng, Qian; Li, Penghui; Cai, Yunfeng; Zhou, Wei; Wang, Haidong; Luo, Jiao; Ding, Jianhua; Chen, Huanwen

    2016-02-09

    Exhaled breath contains chemicals that have a diagnostic value in human pathologies. Here in vivo breath analysis of creatinine has been demonstrated by constructing a novel platform based on extractive electrospray ionization mass spectrometry (EESI-MS) without sample pretreatment. Under optimized experimental conditions, the limit of creatinine detection in breath was 30.57 ng L(-1), and the linear range of detection was from 0.3 μg L(-1) to 100 μg L(-1). The concentration range of creatinine in the exhaled breath of 50 volunteers with chronic kidney disease was from 42 pptv to 924 pptv, and the range of the relative standard deviations was from 9.3% to 19.2%. The method provides high sensitivity, high specificity and high speed for semi-quantitative analysis of creatinine in exhaled human breath.

  10. Salvage microbiology: opportunities and challenges in the detection of bacterial pathogens following initiation of antimicrobial treatment

    PubMed Central

    Farrell, John J.; Hujer, Andrea M.; Sampath, Rangarajan; Bonomo, Robert A.

    2015-01-01

    Broad-range 16S ribosomal RNA gene PCR coupled with Sanger sequencing was originally employed by soil scientists and was subsequently adapted for clinical applications. PCR coupled with electrospray ionization mass spectrometry has also progressed from initial applications in the detection of organisms from environmental samples into the clinical realm and has demonstrated promise in detection of pathogens in clinical specimens obtained from patients with suspected infection but negative cultures. We review studies of multiplex PCR, 16S ribosomal RNA gene PCR and sequencing and PCR coupled with electrospray ionization mass spectrometry for detection of bacteria in specimens that were obtained from patients during or after administration of antibiotic treatment, and examine the role of each for assisting in antimicrobial treatment and stewardship efforts. Following an exploration of the available data in this field we discuss the opportunities that the preliminary investigations reveal, as well as the challenges faced with implementation of these strategies in clinical practice. PMID:25523281

  11. Ambient aerodynamic ionization source for remote analyte sampling and mass spectrometric analysis.

    PubMed

    Dixon, R Brent; Sampson, Jason S; Hawkridge, Adam M; Muddiman, David C

    2008-07-01

    The use of aerodynamic devices in ambient ionization source development has become increasingly prevalent in the field of mass spectrometry. In this study, an air ejector has been constructed from inexpensive, commercially available components to incorporate an electrospray ionization emitter within the exhaust jet of the device. This novel aerodynamic device, herein termed remote analyte sampling, transport, and ionization relay (RASTIR) was used to remotely sample neutral species in the ambient and entrain them into an electrospray plume where they were subsequently ionized and detected using a linear ion trap Fourier transform mass spectrometer. Two sets of experiments were performed in the ambient environment to demonstrate the device's utility. The first involved the remote (approximately 1 ft) vacuum collection of pure sample particulates (i.e., dry powder) from a glass slide, entrainment and ionization at the ESI emitter, and mass spectrometric detection. The second experiment involved the capture (vacuum collection) of matrix-assisted laser desorbed proteins followed by entrainment in the ESI emitter plume, multiple charging, and mass spectrometric detection. This approach is in principle a RASTIR-assisted matrix-assisted laser desorption electrospray ionization source (Sampson, J. S.; Hawkridge, A. M.; Muddiman, D. C. J. Am. Soc. Mass Spectrom. 2006, 17, 1712-1716; Rapid Commun. Mass Spectrom. 2007, 21, 1150-1154.). A detailed description of the device construction, operational parameters, and preliminary small molecule and protein data are presented.

  12. [Simultaneous determination of sixteen perfluorinated organic compounds in surface water by solid phase extraction and ultra performance liquid chromatography with electrospray ionization tandem mass spectrometry].

    PubMed

    Zhang, Ming; Tang, Fangliang; Yu, Yayun; Chen, Feng; Xu, Jianfen; Ye, Yonggen

    2014-05-01

    A high-throughput detection method has been developed for the determination of sixteen perfluorinated organic compounds (PFCs) in surface water by solid phase extraction-ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (SPE-UPLC-ESI-MS/MS). The water samples were concentrated and purified through WAX solid phase extraction cartridges. The UPLC separation was performed on an ACQUITY UPLC BEH C18 column utilizing a gradient elution program of methanol (containing 2 mmol/L ammonium acetate) and water (containing 2 mmol/L ammonium acetate) as the mobile phases at a flow rate of 0.4 mL/min. The MS/MS detection was performed under negative electrospray ionization ( ESI ) in multiple reaction monitoring (MRM) mode. Good linearities were observed in the range of 0.5-100 gg/L or 1.0 - 100 microg/L with correlation coefficients from 0.998 7 to 0.999 9. The limits of detection (LODs) for the sixteen perfluorinated organic compounds were in the range of 0.06-0.46 ng/L. The recoveries ranged from 67.6% to 103% with the relative standard deviations between 2.94% and 12.0%. This method was characterized by high sensitivity and precision, extensive range and high speed, and can be applied for the analysis of PFC contaminants in surface water.

  13. Determination of short chain carboxylic acids in vegetable oils and fats using ion exclusion chromatography electrospray ionization mass spectrometry.

    PubMed

    Viidanoja, Jyrki

    2015-02-27

    A new method for quantification of short chain C1-C6 carboxylic acids in vegetable oils and fats by employing Liquid Chromatography Mass Spectrometry (LC-MS) has been developed. The method requires minor sample preparation and applies non-conventional Electrospray Ionization (ESI) liquid phase chemistry. Samples are first dissolved in chloroform and then extracted using water that has been spiked with stable isotope labeled internal standards that are used for signal normalization and absolute quantification of selected acids. The analytes are separated using Ion Exclusion Chromatography (IEC) and detected with Electrospray Ionization Mass Spectrometry (ESI-MS) as deprotonated molecules. Prior to ionization the eluent that contains hydrochloric acid is modified post-column to ensure good ionization efficiency of the analytes. The averaged within run precision and between run precision were generally lower than 8%. The accuracy was between 85 and 115% for most of the analytes. The Lower Limit of Quantification (LLOQ) ranged from 0.006 to 7mg/kg. It is shown that this method offers good selectivity in cases where UV detection fails to produce reliable results. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Absolute Quantification of Norovirus Capsid Protein in Food, Water, and Soil Using Synthetic Peptides with Electrospray and MALDI Mass Spectrometry

    PubMed Central

    Hartmann, Erica M.; Colquhoun, David R.; Schwab, Kellogg J.; Halden, Rolf U.

    2015-01-01

    Norovirus infections are one of the most prominent public health problems of microbial origin in the U.S. and other industrialized countries. Surveillance is necessary to prevent secondary infection, confirm successful cleanup after outbreaks, and track the causative agent. Quantitative mass spectrometry, based on absolute quantitation with stable-isotope labeled peptides, is a promising tool for norovirus monitoring because of its speed, sensitivity, and robustness in the face of environmental inhibitors. In the current study, we present two new methods for the detection of the norovirus genogroup I capsid protein using electrospray and matrixassisted laser desorption/ionization (MALDI) mass spectrometry. The peptide TLDPIEVPLEDVR was used to quantify norovirus-like particles down to 500 attomoles with electrospray and 100 attomoles with MALDI. With MALDI, we also demonstrate a detection limit of 1 femtomole and a quantitative dynamic range of 5 orders of magnitude in the presence of an environmental matrix effect. Due to the rapid processing time and applicability to a wide range of environmental sample types (bacterial lysate, produce, milk, soil, and groundwater), mass spectrometry-based absolute quantitation has a strong potential for use in public health and environmental sciences. PMID:25603302

  15. Tinted windows: The presence of the UV absorbing compounds called mycosporine-like amino acids embedded in the frustules of marine diatoms

    NASA Astrophysics Data System (ADS)

    Ingalls, Anitra E.; Whitehead, Kenia; Bridoux, Maxime C.

    2010-01-01

    Diatom frustule-bound organic compounds presumably play an important role in biomineralization and constitute an important pool of organic matter preserved in diatom frustule-rich sediments. In this study, detailed analysis of diatom frustule-bound organic matter in opal-rich Southern Ocean plankton and sediments revealed for the first time the presence of low molecular weight, UV light absorbing compounds called mycosporine-like amino acids (MAAs). Chemically cleaned diatom frustule-derived biosilica was dissolved in HF, releasing bound or entrapped organic compounds that were subsequently characterized using liquid chromatography with UV-Vis and electrospray ionization mass spectrometry (LC/PDA/ESI-MS). Palythine ([M+H] + = 245), porphyra-334 ([M+H] + = 347) and shinorine ([M+H] + = 333) were the most abundant MAAs detected in HF digests of plankton and sediment. Traces of asterina ([M+H] + = 289), palythinol ([M+H] + = 303) and palythinic acid ([M+H] + = 329) were also detected. MAAs in cleaned HF digested frustules were up to two orders of magnitude more abundant than methanol extractable MAAs. MAAs are substituted with acid hydrolysable amino acid residues. Our results suggest that MAAs, and not proteins, could be responsible for the high proportion of the amino acids glycine and threonine found in hydrolysates of HF digested diatom-rich environmental samples. Total MAAs accounted for 3-27% of the carbon and 2-18% of total nitrogen in the frustules undergoing various chemical cleaning treatments. This is the first report of MAAs in close association with a mineral phase and we hypothesize that the mineral matrix could stabilize these compounds, thereby enhancing photoprotection against the harmful effects of UV light. The presence of frustule-bound MAAs in sediment cores further suggests the possibility that they could be used in compound-specific isotope analysis of diatom-bound organic matter and as indicators of past solar irradiance.

  16. Determination of green tea catechins in human plasma using liquid chromatography-electrospray ionization mass spectrometry.

    PubMed

    Masukawa, Yoshinori; Matsui, Yuji; Shimizu, Namii; Kondou, Naoki; Endou, Hidenori; Kuzukawa, Michiya; Hase, Tadashi

    2006-04-13

    A method for the sensitive and specific determination of eight green tea catechins, consisting of catechin (C), epicatechin (EC), gallocatechin (GC), epigallocatechin (EGC), catechin-3-gallate (CG), epicatechin-3-gallate (ECG), gallocatechin-3-gallate (GCG) and epigallocatechin-3-gallate (EGCG), in human plasma was established. For optimization of conditions for LC-ESIMS, the separation of the eight catechins was achieved chromatographically using Inertsil ODS-2 column combined with a gradient elution system of 0.1M aqueous acetic acid and 0.1M acetic acid in acetonitrile. Detection using a mass spectrometer was performed with selected ion monitoring at m/z=289 for E and EC, 305 for GC and EGC, 441 for CG and ECG, and 457 for GCG and EGCG under negative ESI. A preparative procedure, consisting of the addition of perchloric acid and acetonitrile to the plasma for deproteinizing and the subsequent addition of potassium carbonate solution to remove excess acid, was developed. In six different plasma with the eight catechins spiked at two different concentrations, the average recoveries were in the range between 72.7 and 84.1%, which resulted from the matrix effect and preparative loss, with coefficients of variance being 8.2-19.8% among individuals. The levels of the catechins in prepared plasma solutions that were kept at 5 degrees C within 24h were stable, which allows us to simply analyze many prepared plasma solutions using an autosampler overnight. When using this method to analyze the eight catechins in human plasma after oral ingestion of a commercial green tea beverage, we detected all the catechins absorbed into human blood for the first time. This also suggested that extremely small amounts of the eight catechins orally ingested may be absorbed based on each absorptive property for the catechins. The method should enable pharmacokinetic studies of green tea catechins in humans.

  17. Structural characterization of phenolics and betacyanins in Gomphrena globosa by high-performance liquid chromatography-diode array detection/electrospray ionization multi-stage mass spectrometry.

    PubMed

    Ferreres, Federico; Gil-Izquierdo, Angel; Valentão, Patrícia; Andrade, Paula B

    2011-11-30

    The metabolite profiling of Gomphrena globosa inflorescences was performed by high-performance liquid chromatography-diode array detection/electrospray ionization multi-stage mass spectrometry (HPLC-DAD/ESI-MS(n)). Based on the fragmentation patterns, 24 phenolic compounds were characterized. The identified phenolics include p-coumaric and ferulic acids, quercetin, kaempferol, isorhamnetin, and hydroxylated 6,7-methylenedioxyflavone derivatives, as well as their aglycones, none of them reported before in the species. This is also the first time that tetrahydroxy-methylenedioxyflavone derivatives and acetylglycosides are described in nature. Betacyanins were also found. This study significantly extends the knowledge of the G. globosa metabolome, by providing further insights into its phenolic composition. Copyright © 2011 John Wiley & Sons, Ltd.

  18. DETECTION OF ARSENOSUGARS FROM KELP EXTRACTS VIA IC-ELECTROSPRAY IONIZATION-MS-MS AND IC MEMBRANE HYDRIDE GENERATION ICP-MS

    EPA Science Inventory

    The selectivity and the ability to obtain structural information from detection schemes used in arsenic speciation research are growing analytical requirements driven by the growing number of arsenicalS extracted from natural products and the need to minimize misidentification in...

  19. Improved Peak Detection and Deconvolution of Native Electrospray Mass Spectra from Large Protein Complexes.

    PubMed

    Lu, Jonathan; Trnka, Michael J; Roh, Soung-Hun; Robinson, Philip J J; Shiau, Carrie; Fujimori, Danica Galonic; Chiu, Wah; Burlingame, Alma L; Guan, Shenheng

    2015-12-01

    Native electrospray-ionization mass spectrometry (native MS) measures biomolecules under conditions that preserve most aspects of protein tertiary and quaternary structure, enabling direct characterization of large intact protein assemblies. However, native spectra derived from these assemblies are often partially obscured by low signal-to-noise as well as broad peak shapes because of residual solvation and adduction after the electrospray process. The wide peak widths together with the fact that sequential charge state series from highly charged ions are closely spaced means that native spectra containing multiple species often suffer from high degrees of peak overlap or else contain highly interleaved charge envelopes. This situation presents a challenge for peak detection, correct charge state and charge envelope assignment, and ultimately extraction of the relevant underlying mass values of the noncovalent assemblages being investigated. In this report, we describe a comprehensive algorithm developed for addressing peak detection, peak overlap, and charge state assignment in native mass spectra, called PeakSeeker. Overlapped peaks are detected by examination of the second derivative of the raw mass spectrum. Charge state distributions of the molecular species are determined by fitting linear combinations of charge envelopes to the overall experimental mass spectrum. This software is capable of deconvoluting heterogeneous, complex, and noisy native mass spectra of large protein assemblies as demonstrated by analysis of (1) synthetic mononucleosomes containing severely overlapping peaks, (2) an RNA polymerase II/α-amanitin complex with many closely interleaved ion signals, and (3) human TriC complex containing high levels of background noise. Graphical Abstract ᅟ.

  20. Sensitive ionization of non-volatile analytes using protein solutions as spray liquid in desorption electrospray ionization mass spectrometry.

    PubMed

    Zhu, Zhiqiang; Han, Jing; Zhang, Yan; Zhou, Yafei; Xu, Ning; Zhang, Bo; Gu, Haiwei; Chen, Huanwen

    2012-12-15

    Desorption electrospray ionization (DESI) is the most popular ambient ionization technique for direct analysis of complex samples without sample pretreatment. However, for many applications, especially for trace analysis, it is of interest to improve the sensitivity of DESI-mass spectrometry (MS). In traditional DESI-MS, a mixture of methanol/water/acetic acid is usually used to generate the primary ions. In this article, dilute protein solutions were electrosprayed in the DESI method to create multiply charged primary ions for the desorption ionization of trace analytes on various surfaces (e.g., filter paper, glass, Al-foil) without any sample pretreatment. The analyte ions were then detected and structurally characterized using a LTQ XL mass spectrometer. Compared with the methanol/water/acetic acid (49:49:2, v/v/v) solution, protein solutions significantly increased the signal levels of non-volatile compounds such as benzoic acid, TNT, o-toluidine, peptide and insulin in either positive or negative ion detection mode. For all the analytes tested, the limits of detection (LODs) were reduced to about half of the original values which were obtained using traditional DESI. The results showed that the signal enhancement is highly correlated with the molecular weight of the proteins and the selected solid surfaces. The proposed DESI method is a universal strategy for rapid and sensitive detection of trace amounts of strongly bound and/or non-volatile analytes, including explosives, peptides, and proteins. The results indicate that the sensitivity of DESI can be further improved by selecting larger proteins and appropriate solid surfaces. Copyright © 2012 John Wiley & Sons, Ltd.

  1. Research of the absorbance detection and fluorescence detection for multifunctional nutrition analyzer

    NASA Astrophysics Data System (ADS)

    Ni, Zhengyuan; Yan, Huimin; Ni, Xuxiang; Zhang, Xiuda

    2017-10-01

    The research of the multifunctional analyzer which integrates absorbance detection, fluorescence detection, time-resolved fluorescence detection, biochemical luminescence detection methods, can make efficient detection and analysis for a variety of human body nutrients. This article focuses on the absorbance detection and fluorescence detection system. The two systems are modular in design and controlled by embedded system, to achieve automatic measurement according to user settings. In the optical path design, the application of confocal design can improve the optical signal acquisition capability, and reduce the interference. A photon counter is used for detection, and a high performance counter module is designed to measure the output of photon counter. In the experiment, we use neutral density filters and potassium dichromate solution to test the absorbance detection system, and use fluorescein isothiocyanate FITC for fluorescence detection system performance test. The experimental results show that the absorbance detection system has a detection range of 0 4OD, and has good linearity in the detection range, while the fluorescence detection system has a high sensitivity of 1pmol/L concentration.

  2. Pharmacokinetic and ocular microdialysis study of oral ginkgo biloba extract in rabbits by UPLC-MS/MS determination.

    PubMed

    Wang, Shuya; Li, Ding; Pi, Jiaxin; Li, Wen; Zhang, Bing; Qi, Dongli; Li, Nan; Guo, Pan; Liu, Zhidong

    2017-11-01

    The purpose of this work was to determine and investigate the absorption of ginkgo terpenoids (GT) in plasma and aqueous humour after oral administration of ginkgo biloba extract (GBE) by UPLC-MS/MS method. The UPLC-MS/MS determination of GT employed the multiple reaction monitoring mode using an electrospray negative ionization. The rabbits were orally administered the suspension of GBE at a dose of 500 mg/kg. Serial plasma and dialysate samples were collected at the corresponding time and then analysed by UPLC-MS/MS. In plasma, the mean AUC from 0 to 48 h was 14.12, 12.59, 23.75, 1.51 h μg/ml for GLJ and 5.34 h μg/ml for GLA, GLB, GLC, GLJ and BLL, respectively. In aqueous humour, the five ginkgo terpenoids have been detected. Compared with the other four GT, BLL has better absorption in the eyes. A selective and reproducible UPLC-MS/MS method was developed and validated to determine and investigate the absorption of ginkgo terpenoids in plasma and aqueous humour of rabbits after oral administration of GBE. The main five ginkgo terpenoids could be absorbed into eyes. © 2017 Royal Pharmaceutical Society.

  3. Residual Agar Determination in Bacterial Spores by Electrospray Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wahl, Karen L.; Colburn, Heather A.; Wunschel, David S.

    2010-02-15

    Presented here is an analytical method to detect residual agar from a bacterial spore sample as an indication of culturing on an agar plate. This method is based on the resolubilization of agar polysaccharide from a bacterial spore sample, enzymatic digestion, followed by electrospray ionization tandem mass spectrometry (ESI-MSn) analysis for detection of a specific agar fragment ion. A range of Bacillus species and strains were selected to demonstrate the effectiveness of this approach. The characteristic agar fragment ion was detected in the spores grown on agar that were washed from 1 to 5 times, irradiated or non-irradiated and notmore » in the spores grown in broth. A sample containing approximately 108 spores is currently needed for confident detection of residual agar from culture on agar plates in the presence of bacterial spores with a limit of detection of approximately 1 ppm agar spiked into a broth-grown spore sample. The results of a proficiency test with 42 blinded samples are presented demonstrating the utility of this method with no false positives and only 3 false negatives for samples that were below the detection level of the method as documented.« less

  4. Metal cation detection in positive ion mode electrospray ionization mass spectrometry using a tetracationic salt as a gas-phase ion-pairing agent: evaluation of the effect of chelating agents on detection sensitivity.

    PubMed

    Xu, Chengdong; Dodbiba, Edra; Padivitage, Nilusha L T; Breitbach, Zachary S; Armstrong, Daniel W

    2012-12-30

    The detection of metal cations continues to be essential in many scientific and industrial areas of interest. The most common electrospray ionization mass spectrometry (ESI-MS) approach involves chelating the metal ions and detecting the organometallic complex in the negative ion mode. However, it is well known that negative ion mode ESI-MS is generally less sensitive than the positive ion mode. To achieve greater sensitivity, it is necessary to examine the feasibility of detecting the chelated metal cations in positive ion mode ESI-MS. Since highly solvated native metal cations have relatively low ionization efficiency in ESI-MS, and can be difficult to detect in the positive ion mode, a tetracationic ion-pairing agent was added to form a complex with the negatively charged metal chelate. The use of the ion-pairing agent leads to the generation of an overall positively charged complex, which can be detected at higher m/z values in the positive ion mode by electrospray ionization linear quadrupole ion trap mass spectrometry. Thirteen chelating agents with diverse structures were evaluated in this study. The nature of the chelating agent played as important a role as was previously determined for cationic pairing agents. The detection limits of six metal cations reached sub-picogram levels and significant improvements were observed when compared to negative ion mode detection where the metal-chelates were monitored without adding the ion-pairing reagent (IPR). Also, selective reaction monitoring (SRM) analyses were performed on the ternary complexes, which improved detection limits by one to three orders of magnitude. With this method it was possible to analyze the metal cations in the positive ion mode ESI-MS with the advantage of speed, sensitivity and selectivity. The optimum solution pH for this type of analysis is 5-7. Tandem mass spectrometry (MS/MS) further increases the sensitivity. Speciation is straightforward making this a broadly useful approach for the analysis of metal ions. Copyright © 2012 John Wiley & Sons, Ltd.

  5. Study of Simvastatin Self-Association Using Electrospray-Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Vetrova, E. V.; Lekar, A. V.; Filonova, O. V.; Borisenko, S. N.; Maksimenko, E. V.; Borisenko, N. I.

    2015-07-01

    Self-association of simvastatin, which is widely used to treat coronary heart disease, was investigated using electrospray-ionization mass spectrometry. Formation of simvastatin self-associates in various solvents was demonstrated using mass spectrometry. Solvation effects were shown to play a special role in the formation of the self-associates. Self-associates containing from two to fi ve simvastatin molecules were detected in mass spectra of an aqueous MeOH (20%) solution of simvastatin. The formation of simvastatin self-associates could compete with the complexation of supramolecular structures during the synthesis of new generation drugs.

  6. A Combined Desorption Ionization by Charge Exchange (DICE) and Desorption Electrospray Ionization (DESI) Source for Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Chan, Chang-Ching; Bolgar, Mark S.; Miller, Scott A.; Attygalle, Athula B.

    2011-01-01

    A source that couples the desorption ionization by charge exchange (DICE) and desorption electrospray ionization (DESI) techniques together was demonstrated to broaden the range of compounds that can be analyzed in a single mass spectrometric experiment under ambient conditions. A tee union was used to mix the spray reagents into a partially immiscible blend before this mixture was passed through a conventional electrospray (ES) probe capillary. Using this technique, compounds that are ionized more efficiently by the DICE method and those that are ionized better with the DESI procedure could be analyzed simultaneously. For example, hydroquinone, which is not detected when subjected to DESI-MS in the positive-ion generation mode, or the sodium adduct of guaifenesin, which is not detected when examined by DICE-MS, could both be detected in one experiment when the two techniques were combined. The combined technique was able to generate the molecular ion, proton and metal adduct from the same compound. When coupled to a tandem mass spectrometer, the combined source enabled the generation of product ion spectra from the molecular ion and the [M + H]+ or [M + metal]+ ions of the same compound without the need to physically change the source from DICE to DESI. The ability to record CID spectra of both the molecular ion and adduct ions in a single mass spectrometric experiment adds a new dimension to the array of mass spectrometric methods available for structural studies.

  7. Simultaneous analysis of ten phytohormones in Sargassum horneri by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry.

    PubMed

    Li, Yan; Zhou, Chengxu; Yan, Xiaojun; Zhang, Jinrong; Xu, Jilin

    2016-05-01

    Phytohormones have attracted wide attention due to their important biological functions. However, their detection is still a challenge because of their complex composition, low abundance and diverse sources. In this study, a novel method of high-performance liquid chromatography with electrospray ionization tandem mass spectrometry was developed and validated for the simultaneous determination of ten phytohormones including indole-3-acetic acid, isopentenyladenine, isopentenyl adenosine, trans-zeatin riboside, zeatin, strigolactones, abscisic acid, salicylic acid, gibberellin A3, and jasmonic acid in Sargassum horneri (S. horneri). The phytohormones were extracted from freeze-dried S. horneri with methanol/water/methanoic acid (15:4:1, v/v/v) analyzed on a Hypersil Gold C18 column and detected by electrospray ionization tandem triple quadrupole mass spectrometry in the multiple reaction monitoring mode. The experimental conditions for the extraction and analysis of phytohormones were optimized and validated in terms of reproducibility, linearity, sensitivity, recovery, accuracy, and stability. Distributions of the phytohormones in the stems, blades, and gas bladder of the S. horneri in drift, fixed, and semi-fixed growing states were investigated for the first time. The observed contents of the phytohormones in S. horneri range from not detected to 5066.67 ng/g (fresh weight). Most phytohormones are distributed mainly in the stems of S. horneri in drift and semi-fixed states. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Rapid analysis of N-linked oligosaccharides in glycoproteins (ovalbumin, ribonuclease B and fetuin) by reversed-phase ultra-performance liquid chromatography with fluorescence detection and electrospray ionization time-of-flight mass spectrometry.

    PubMed

    Kurihara, Takamasa; Min, Jun Zhe; Hirata, Asuka; Toyo'oka, Toshimasa; Inagaki, Shinsuke

    2009-05-01

    Rapid, selective and sensitive determination of N-linked oligosaccharides in glycoproteins (ovalbumin, ribonuclease B and fetuin) was performed by ultra-performance liquid chromatography (UPLC) with fluorescence (FL) and electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS). The asparaginyl-oligosaccharide moiety was first liberated from each glycoprotein by pronase E (a proteolitic enzyme). The oligosaccharide fractions separated by gel-permeation chromatography were labeled with 1-pyrenesulfonyl chloride (PSC, a fluorescence reagent), separated by UPLC in a short run time, and then detected by FL and TOF-MS. The PSC-labeled oligosaccharides were selectively identified from the FL detection and then sensitively determined by ESI-TOF-MS. As the results, 15, eight and four kinds of N-linked oligosaccharides were detected from ovalbumin, ribonuclease B and fetuin, respectively. Because the present method is rapid (within 9 min), selective and sensitive (approximate 60 fmol, S/N = 5), the determination of N-linked oligosaccharides in various glycoproteins seems to be possible.

  9. Rapid screening of basic colorants in processed vegetables through mass spectrometry using an interchangeable thermal desorption electrospray ionization source.

    PubMed

    Chao, Yu-Ying; Chen, Yen-Ling; Lin, Hong-Yi; Huang, Yeou-Lih

    2018-06-20

    Thermal desorption electrospray ionization/mass spectrometry (TD-ESI-MS) employing a quickly interchangeable ionization source is a relatively new ambient ionization mass spectrometric technique that has had, to date, only a limited number of applications related to food safety control. With reallocation of resources, this direct-analysis technique has had wider use in food analysis when operated in dual-working mode (pretreatment-free qualitative screening and conventional quantitative confirmation) after switching to an ambient ionization source from a traditional atmospheric pressure ionization source. Herein, we describe the benefits and challenges associated with the use of a TD-ESI source to detect adulterants in processed vegetables (PVs), as a proof-of-concept for the detection of basic colorants. While TD-ESI can offer direct qualitative screening analyses for PVs with detection capabilities lower than those provided with liquid chromatography/UV detection within 30 s, the use of TD-ESI for semi-quantification is applicable only for homogeneous food matrices. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Rapid detection of illegal colorants on traditional Chinese pastries through mass spectrometry with an interchangeable thermal desorption electrospray ionization source.

    PubMed

    Chao, Yu-Ying; Chen, Yen-Ling; Chen, Wei-Chu; Chen, Bai-Hsiun; Huang, Yeou-Lih

    2018-06-30

    Ambient mass spectrometry using an interchangeable thermal desorption/electrospray ionization source (TD-ESI) is a relatively new technique that has had only a limited number of applications to date. Nevertheless, this direct-analysis technique has potential for wider use in analytical chemistry (e.g., in the rapid direct detection of contaminants, residues, and adulterants on and in food) when operated in dual-working mode (pretreatment-free qualitative screening and conventional quantitative confirmation) after switching to a TD-ESI source from a conventional ESI source. Herein, we describe the benefits and challenges associated with the use of a TD-ESI source to detect adulterants on traditional Chinese pastries (TCPs), as a proof-of-concept for the detection of illegal colorants. While TD-ESI can offer direct (i.e., without any sample preparation) qualitative screening analyses for TCPs with adequate sensitivity within 30 s, the use of TD-ESI for semi-quantification is applicable only for homogeneous matrices (e.g., tang yuan). Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Photochemical Production of Aldehydes and Ketones from Petroleum Films on Seawater

    NASA Astrophysics Data System (ADS)

    Tarr, M. A.; Rebet, K.; Monin, L.; Bastian, G.

    2016-02-01

    While numerous reports have demonstrated that sunlight results in oxygenation of petroleum in environmental systems, few details are available regarding the specific mechanisms of these reactions. Previous studies have not been able to identify specific chemicals formed when oil is subjected to photochemical transformation. In this study, we have utilized several petroleum samples to investigate the formation of aldehyde and ketone photoproducts. These samples included oil from the MC252 well (source of the Deepwater Horizon spill), surrogate oil provided by BP to represent the MC252 oil, and residual fuel oil (NIST 2717a). Thin films of oil ( 100 μm) were placed over water and irradiated with a solar simulator for the equivalent of 1.5-12 days. After irradiation, the water was carefully separated from the oil and derivatized with 2,4-dinitrophenylhydrazine, a selective derivatization agent for aldehydes and ketones. The derivatized material was then analyzed by HPLC. Additional analysis by electrospray MS was also performed, and absorbance and fluorescence spectra of the underivatized aqueous phase were recorded. For all oils, exposure to sunlight resulted in release of aldehydes and ketones to the aqueous phase. The amount of released photoproducts was proportional to the length of solar exposure, but no production was seen for dark controls. Despite some similarities, the pattern of product formation varied from oil to oil. Addition of dispersant (Corexit 9500a or 9527a) resulted in larger amounts of aldehydes and ketones detected in the aqueous phase after solar irradiation of the oil. Electrospray mass spectrometry was utilized in an attempt to provide structural information about the aldehydes and ketones formed. Results of this study demonstrate that aldehydes and ketones are important photoproducts resulting from solar irradiation of oil on water. These products will affect the transport and bioavailability of oil spilled in aquatic systems.

  12. Radial arrays of nano-electrospray ionization emitters and methods of forming electrosprays

    DOEpatents

    Kelly, Ryan T [West Richland, WA; Tang, Keqi [Richland, WA; Smith, Richard D [Richland, WA

    2010-10-19

    Electrospray ionization emitter arrays, as well as methods for forming electrosprays, are described. The arrays are characterized by a radial configuration of three or more nano-electrospray ionization emitters without an extractor electrode. The methods are characterized by distributing fluid flow of the liquid sample among three or more nano-electrospray ionization emitters, forming an electrospray at outlets of the emitters without utilizing an extractor electrode, and directing the electrosprays into an entrance to a mass spectrometry device. Each of the nano-electrospray ionization emitters can have a discrete channel for fluid flow. The nano-electrospray ionization emitters are circularly arranged such that each is shielded substantially equally from an electrospray-inducing electric field.

  13. Coupling corona discharge for ambient extractive ionization mass spectrometry.

    PubMed

    Hu, Bin; Zhang, Xinglei; Li, Ming; Peng, Xuejiao; Han, Jing; Yang, Shuiping; Ouyang, Yongzhong; Chen, Huanwen

    2011-12-07

    Unlike the extractive electrospray ionization (EESI) technique described elsewhere, a corona discharge instead of electrospray ionization has been utilized to charge a neutral solvent spray under ambient conditions for the generation of highly charged microdroplets, which impact a neutral sample plume for the extractive ionization of the analytes in raw samples without any sample pretreatment. Using the positive ion mode, molecular radical cations were easily generated for the detection of non-polar compounds (e.g., benzene, cyclohexane, etc.), while protonated molecular ions of polar compounds (e.g., acetonitrile, acetic ether) were readily produced for the detection. By dispensing the matrix in a relatively large space, this method tolerates highly complex matrices. For a given sample such as lily fragrances, more compounds were detected by the method established here than the EESI technique. An acceptable relative standard deviation (RSD 8.9%, n = 11) was obtained for the direct measurement of explosives (10 ppb) in waste water samples. The experimental data demonstrate that this method could simultaneously detect both polar and non-polar analytes with high sensitivity, showing promising applications for the rapid detection of a wide variety of compounds present in complex matrices.

  14. Feasibility study of mid-infrared absorption spectroscopy using electrospray ionization

    NASA Astrophysics Data System (ADS)

    Ahmed, Tahsin; Foster, Erick; Bohn, Paul; Howard, Scott

    2016-09-01

    Precise detection of trace amount of molecules, such as the disease biomarkers present in biofluids or explosive residues, requires high sensitivity detection. electrospray ionization-mass spectrometry (ESI-MS) is a common and effective technique for sensitive trace molecular detection in small-volume liquid samples. In ESI-MS, nano-liter volume samples are ionized and aerosolized by ESI, and fed into MS for mass analysis. ESI-MS has proven to be a reliable ionization technique for coupling liquid phase separations like liquid chromatography (LC) and capillary zone electrophoresis (CE) with the highly specific resolving power of MS. While CE and ESI can be performed on a microfluidic chip having a footprint of a few cm2, MS is typically at least 100 times bigger in size than a micro-chip. A reduced size, weight, and power profile would enable semi-portable applications in forensics, environmental monitoring, defense, and biological/pharmaceutical applications. To achieve this goal, we present an initial study evaluating the use of mid-infrared absorption spectroscopy (MIRAS) in place of MS to create a ESI-MIRAS system. To establish feasibility, we perform ESI-MIRAS on phospholipid samples, which have been previously demonstrated to be separable by CE. Phospholipids are biomarkers of degenerative neurological, kidney, and bone diseases and can be found in biofluids such as blood, urine and cerebrospinal fluid. To establish sensitivity limits, calibration samples of 100 μM concentration are electrospray deposited on to a grounded Si wafer for different times (1 minutes to 4 minutes with a 1 minute step). The minimum detectable concentration-time product, where a FTIR globar is used as the MIR source, is found 200 μM·s.

  15. Apparatus and method of determining molecular weight of large molecules

    DOEpatents

    Fuerstenau, S.; Benner, W.H.; Madden, N.M.; Searles, W.

    1998-06-23

    A mass spectrometer determines the mass of multiply charged high molecular weight molecules. This spectrometer utilizes an ion detector which is capable of simultaneously measuring the charge z and transit time of a single ion as it passes through the detector. From this transit time, the velocity of the single ion may then be derived, thus providing the mass-to-charge ratio m/z for a single ion which has been accelerated through a known potential. Given z and m/z, the mass m of the single ion can then be calculated. Electrospray ions with masses in excess of 1 MDa and charge numbers greater than 425 e{sup {minus}} are readily detected. The on-axis single ion detection configuration enables a duty cycle of nearly 100% and extends the practical application of electrospray mass spectrometry to the analysis of very large molecules with relatively inexpensive instrumentation. 14 figs.

  16. Apparatus and method of determining molecular weight of large molecules

    DOEpatents

    Fuerstenau, Stephen; Benner, W. Henry; Madden, Norman; Searles, William

    1998-01-01

    A mass spectrometer determines the mass of multiply charged high molecular weight molecules. This spectrometer utilizes an ion detector which is capable of simultaneously measuring the charge z and transit time of a single ion as it passes through the detector. From this transit time, the velocity of the single ion may then be derived, thus providing the mass-to-charge ratio m/z for a single ion which has been accelerated through a known potential. Given z and m/z, the mass m of the single ion can then be calculated. Electrospray ions with masses in excess of 1 MDa and charge numbers greater than 425 e.sup.- are readily detected. The on-axis single ion detection configuration enables a duty cycle of nearly 100% and extends the practical application of electrospray mass spectrometry to the analysis of very large molecules with relatively inexpensive instrumentation.

  17. High-performance liquid chromatography/electrospray mass spectrometry for the analysis of modified bases in DNA: 7-(2-hydroxyethyl)guanine, the major ethylene oxide-DNA adduct.

    PubMed

    Leclercq, L; Laurent, C; De Pauw, E

    1997-05-15

    A method was developed for the analysis of 7-(2-hydroxyethyl)guanine (7HEG), the major DNA adduct formed after exposure to ethylene oxide (EO). The method is based on DNA neutral thermal hydrolysis, adduct micro-concentration, and final characterization and quantification by HPLC coupled to single-ion monitoring electrospray mass spectrometry (HPLC/SIR-ESMS). The method was found to be selective, sensitive, and easy to handle with no need for enzymatic digestion or previous sample derivatization. Detection limit was found to be close to 1 fmol of adduct injected (10(-10) M), thus allowing the detection of approximately three modified bases on 10(8) intact nucleotides in blood sample analysis. Quantification results are shown for 7HEG after calf thymus DNA and blood exposure to various doses of EO, in both cases obtaining clear dose-response relationships.

  18. Combining bio-electrospraying with gene therapy: a novel biotechnique for the delivery of genetic material via living cells.

    PubMed

    Ward, Eliot; Chan, Emma; Gustafsson, Kenth; Jayasinghe, Suwan N

    2010-05-01

    The investigations reported in this article demonstrate the ability of bio-electrosprays and cell electrospinning to deliver a genetic construct in association with living cells. Previous studies on both bio-electrosprays and cell electrospinning demonstrated great promise for tissue engineering and regenerative biology/medicine. The investigations described herein widen the applicability of these biotechniques by combining gene therapy protocols, resulting in a novel drug delivery methodology previously unexplored. In these studies a human cell line was transduced with recombinant self-inactivating lentiviral particles. These particles incorporated a green fluorescent protein fused to an endosomal targeting construct. This construct encodes a peptide, which can subsequently be detected on the surface of cells by specific T-cells. The transduced cell line was subsequently manipulated in association with either bio-electrospraying or cell electrospinning. Hence this demonstrates (i) the ability to safely handle genetically modified living cells and (ii) the ability to directly form pre-determined architectures bearing living therapeutic cells. This merged technology demonstrates a unique approach for directly forming living therapeutic architectures for controlled and targeted release of experimental cells/genes, as well as medical cell/gene therapeutics for a plethora of biological and medical applications. Hence, such developments could be applied to personalised medicine.

  19. Electrospray device

    NASA Technical Reports Server (NTRS)

    Demmons, Nathaniel (Inventor); Roy, Thomas (Inventor); Spence, Douglas (Inventor); Martin, Roy (Inventor); Hruby, Vladimir (Inventor); Ehrbar, Eric (Inventor); Zwahlen, Jurg (Inventor)

    2011-01-01

    An electrospray device includes an electrospray emitter adapted to receive electrospray fluid; an extractor plate spaced from the electrospray emitter and having at least one aperture; and a power supply for applying a first voltage between the extractor plate and emitter for generating at least one Taylor cone emission through the aperture to create an electrospray plume from the electrospray fluid, the extractor plate as well as accelerator and shaping plates may include a porous, conductive medium for transporting and storing excess, accumulated electrospray fluid away from the aperture.

  20. Multispectral photoacoustic tomography for detection of small tumors inside biological tissues

    NASA Astrophysics Data System (ADS)

    Hirasawa, Takeshi; Okawa, Shinpei; Tsujita, Kazuhiro; Kushibiki, Toshihiro; Fujita, Masanori; Urano, Yasuteru; Ishihara, Miya

    2018-02-01

    Visualization of small tumors inside biological tissue is important in cancer treatment because that promotes accurate surgical resection and enables therapeutic effect monitoring. For sensitive detection of tumor, we have been developing photoacoustic (PA) imaging technique to visualize tumor-specific contrast agents, and have already succeeded to image a subcutaneous tumor of a mouse using the contrast agents. To image tumors inside biological tissues, extension of imaging depth and improvement of sensitivity were required. In this study, to extend imaging depth, we developed a PA tomography (PAT) system that can image entire cross section of mice. To improve sensitivity, we discussed the use of the P(VDF-TrFE) linear array acoustic sensor that can detect PA signals with wide ranges of frequencies. Because PA signals produced from low absorbance optical absorbers shifts to low frequency, we hypothesized that the detection of low frequency PA signals improves sensitivity to low absorbance optical absorbers. We developed a PAT system with both a PZT linear array acoustic sensor and the P(VDF-TrFE) sensor, and performed experiment using tissue-mimicking phantoms to evaluate lower detection limits of absorbance. As a result, PAT images calculated from low frequency components of PA signals detected by the P(VDF-TrFE) sensor could visualize optical absorbers with lower absorbance.

  1. Tapered-Tip Capillary Electrophoresis Nano-Electrospray Ionization Mass Spectrometry for Ultrasensitive Proteomics: the Mouse Cortex

    NASA Astrophysics Data System (ADS)

    Choi, Sam B.; Zamarbide, Marta; Manzini, M. Chiara; Nemes, Peter

    2017-04-01

    Ultrasensitive characterization of the proteome raises the potential to understand how differential gene expression orchestrates cell heterogeneity in the brain. Here, we report a microanalytical capillary electrophoresis nano-flow electrospray ionization (CE-nanoESI) interface for mass spectrometry to enable the measurement of limited amounts of proteins in the mouse cortex. Our design integrates a custom-built CE system to a tapered-tip metal emitter in a co-axial sheath-flow configuration. This interface can be constructed in <15 min using readily available components, facilitating broad adaptation. Tapered-tip CE-nanoESI generates stable electrospray by reproducibly anchoring the Taylor cone, minimizes sample dilution in the ion source, and ensures efficient ion generation by sustaining the cone-jet spraying regime. Parallel reaction monitoring provided a 260-zmol lower limit of detection for angiotensin II (156,000 copies). CE was able to resolve a complex mixture of peptides in 330,000 theoretical plates and identify 15 amol ( 1 pg) of BSA or cytochrome c. Over 30 min of separation, 1 ng protein digest from the mouse cortex yielded 217 nonredundant proteins encompassing a 3-log-order concentration range using a quadrupole time-of-flight mass spectrometer. Identified proteins included many products from genes that are traditionally used to mark oligodendrocytes, astrocytes, and microglia. Finally, key proteins involved in neurodegenerative disorders were detected (e.g., parkinsonism and spastic paraplegia). CE-nanoESI-HRMS delivers sufficient sensitivity to detect proteins in limited amounts of tissues and cell populations to help understand how gene expression differences maintain cell heterogeneity in the brain.

  2. A liquid chromatography-electrospray ionization-tandem mass spectrometry study of ethanolamines in high salinity industrial wastewaters.

    PubMed

    Campo, Pablo; Suidan, Makram T; Chai, Yunzhou; Davis, John

    2010-01-15

    The detection and quantitation of four ethanolamines, tris(2-hydroxyethyl)amine (triethanolamine, TEA), N,N-bis(2-hydroxyethyl)methylamine (methyldiethanolamine, MDEA), N-(2-aminoethyl)ethanolamine (AEA), and N,N-diethylethanolamine (DEA), were achieved in wastewaters from two aerobic activated sludge bioreactors located in an industrial wastewater treatment plant. The streams had salt concentrations of approximately 3% and 7% by weight in Reactor 1 and Reactor 2, respectively. The use of liquid chromatography-electrospray ionization-tandem mass spectrometry avoided the need for some sample preparation steps such as extraction, concentration, and derivatization. Ion suppression in the electrospray, attributable to the presence of sodium clusters, was attenuated by a 10-fold dilution of the wastewaters with acetonitrile. A matrix-matched calibration model averted other potential interferences. For the compounds analyzed in selected reaction monitoring mode (TEA, MDEA, and DEA), the calibration curves presented linearity in a range of 10-1000microg/L with corresponding detection limits ranging from 2 to 11microg/L, depending upon the specific analyte and aqueous matrix. AEA was calibrated in selected ion monitoring mode (100-1000microg/L), with corresponding detection limits in the two wastewaters of 74.6 and 85.3microg/L, respectively. Overall good precision (<10%) and accuracy (97-110%) were achieved for both matrices, which fell within-laboratory reproducibility. Finally, the amines were introduced into six mixed liquor samples from both reactors and quantified following the reported protocol. Again, recoveries were close to 100% with a relative standard deviation of less than 10% in all cases.

  3. Rapid Diagnosis of Infection in the Critically Ill, a Multicenter Study of Molecular Detection in Bloodstream Infections, Pneumonia, and Sterile Site Infections*

    PubMed Central

    Brealey, David; Libert, Nicolas; Abidi, Nour Elhouda; O’Dwyer, Michael; Zacharowski, Kai; Mikaszewska-Sokolewicz, Malgorzata; Schrenzel, Jacques; Simon, François; Wilks, Mark; Picard-Maureau, Marcus; Chalfin, Donald B.; Ecker, David J.; Sampath, Rangarajan; Singer, Mervyn

    2015-01-01

    Objective: Early identification of causative microorganism(s) in patients with severe infection is crucial to optimize antimicrobial use and patient survival. However, current culture-based pathogen identification is slow and unreliable such that broad-spectrum antibiotics are often used to insure coverage of all potential organisms, carrying risks of overtreatment, toxicity, and selection of multidrug-resistant bacteria. We compared the results obtained using a novel, culture-independent polymerase chain reaction/electrospray ionization-mass spectrometry technology with those obtained by standard microbiological testing and evaluated the potential clinical implications of this technique. Design: Observational study. Setting: Nine ICUs in six European countries. Patients: Patients admitted between October 2013 and June 2014 with suspected or proven bloodstream infection, pneumonia, or sterile fluid and tissue infection were considered for inclusion. Interventions: None. Measurements and Main Results: We tested 616 bloodstream infection, 185 pneumonia, and 110 sterile fluid and tissue specimens from 529 patients. From the 616 bloodstream infection samples, polymerase chain reaction/electrospray ionization-mass spectrometry identified a pathogen in 228 cases (37%) and culture in just 68 (11%). Culture was positive and polymerase chain reaction/electrospray ionization-mass spectrometry negative in 13 cases, and both were negative in 384 cases, giving polymerase chain reaction/electrospray ionization-mass spectrometry a sensitivity of 81%, specificity of 69%, and negative predictive value of 97% at 6 hours from sample acquisition. The distribution of organisms was similar with both techniques. Similar observations were made for pneumonia and sterile fluid and tissue specimens. Independent clinical analysis of results suggested that polymerase chain reaction/electrospray ionization-mass spectrometry technology could potentially have resulted in altered treatment in up to 57% of patients. Conclusions: Polymerase chain reaction/electrospray ionization-mass spectrometry provides rapid pathogen identification in critically ill patients. The ability to rule out infection within 6 hours has potential clinical and economic benefits. PMID:26327198

  4. Far-ultraviolet absorbance detection of sugars and peptides by high-performance liquid chromatography.

    PubMed

    Uchiho, Yuichi; Goto, Yusuke; Kamahori, Masao; Aota, Toshimichi; Morisaki, Atsuki; Hosen, Yusuke; Koda, Kimiyoshi

    2015-12-11

    A far-ultraviolet (FUV)-absorbance detector with a transmission flow cell was developed and applied to detect absorbance of sugars and peptides by HPLC. The main inherent limitation of FUV-absorbance detection is the strong absorptions of solvents and atmospheric oxygen in the optical system as well as dissolved oxygen in the solvent. High absorptivity of the solvent and oxygen decreases transmission-light intensity in the flow cell and hinders the absorbance measurement. To solve the above drawbacks, the transmission-light intensity in the flow cell was increased by introducing a new optical system and a nitrogen-purging unit to remove the atmospheric oxygen. The optical system has a photodiode for detecting the reference light at a position of the minus-first-order diffracted light. In addition, acetonitrile and water were selected as usable solvents because of their low absorptivity in the FUV region. As a result of these implementations, the detectable wavelength of the FUV-absorbance detector (with a flow cell having an effective optical path length of 0.5mm) can be extended down to 175nm. Three sugars (glucose, fructose, and sucrose) were successfully detected with the FUV-absorbance detector. These detection results reveal that the absorption peak of sugar in liquid phase lies at around 178nm. The detection limit (S/N=3) in absorbance with a 0.5-mm flow cell at 180nm was 21μAU, which corresponds to 33, 60 and 60μM (198, 360, and 360pmol) for fructose, glucose, and sucrose, respectively. Also, the peptide Met-enkephalin could be detected with a high sensitivity at 190nm. The estimated detection limit (S/N=3) for Met-enkephalin is 29nM (0.29pmol), which is eight times lower than that at 220nm. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Liquid Microjunction Surface Sampling Probe Electrospray Mass Spectrometry for Detection of Drugs and Metabolites in Thin Tissue Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Berkel, Gary J; Kertesz, Vilmos; Koeplinger, Kenneth A.

    2008-01-01

    A self-aspirating, liquid micro-junction surface sampling probe/electrospray emitter mass spectrometry system was demonstrated for use in the direct analysis of spotted and dosed drugs and their metabolites in thin tissue sections. Proof-of-principle sampling and analysis directly from tissue without the need for sample preparation was demonstrated first by raster scanning a region on a section of rat liver onto which reserpine was spotted. The mass spectral signal from selected reaction monitoring was used to develop a chemical image of the spotted drug on the tissue. The probe was also used to selectively spot sample areas of sagittal whole mouse bodymore » tissue sections that had been dosed orally (90 mg/kg) with R,S-sulforaphane 3 hrs prior to sacrifice. Sulforaphane and its glutathione and N-acetyl cysteine conjugates were monitored with selected reaction monitoring and detected in the stomach and various other tissues from the dosed mouse. No signal for these species was observed in the tissue from a control mouse. The same dosed tissue section was used to illustrate the possibility of obtaining a line scan across the whole body section. In total these results illustrate the potential for rapid screening of the distribution of drugs and metabolites in tissue sections with the micro-liquid junction surface sampling probe/electrospray mass spectrometry approach.« less

  6. Rapid detection of terbufos in stomach contents using desorption electrospray ionization mass spectrometry.

    PubMed

    Wilson, Christina R; Mulligan, Christopher C; Strueh, Kurt D; Stevenson, Gregory W; Hooser, Stephen B

    2014-05-01

    Desorption electrospray ionization mass spectrometry (DESI-MS) is an emerging analytical technique that permits the rapid and direct analysis of biological or environmental samples under ambient conditions. Highlighting the versatility of this technique, DESI-MS has been used for the rapid detection of illicit drugs, chemical warfare agents, agricultural chemicals, and pharmaceuticals from a variety of sample matrices. In diagnostic veterinary toxicology, analyzing samples using traditional analytical instrumentation typically includes extensive sample extraction procedures, which can be time consuming and labor intensive. Therefore, efforts to expedite sample analyses are a constant goal for diagnostic toxicology laboratories. In the current report, DESI-MS was used to directly analyze stomach contents from a dog exposed to the organophosphate insecticide terbufos. The total DESI-MS analysis time required to confirm the presence of terbufos and diagnose organophosphate poisoning in this case was approximately 5 min. This highlights the potential of this analytical technique in the field of veterinary toxicology for the rapid diagnosis and detection of toxicants in biological samples. © 2014 The Author(s).

  7. A Comparison of DESI-MS and LC-MS for the Lipidomic Profiling of Human Cancer Tissue

    NASA Astrophysics Data System (ADS)

    Abbassi-Ghadi, Nima; Jones, Emrys A.; Gomez-Romero, Maria; Golf, Ottmar; Kumar, Sacheen; Huang, Juzheng; Kudo, Hiromi; Goldin, Rob D.; Hanna, George B.; Takats, Zoltan

    2016-02-01

    In this study, we make a direct comparison between desorption electrospray ionization-mass spectrometry (DESI-MS) and ultraperformance liquid chromatography-electrospray ionization-mass spectrometry (UPLC-ESI-MS) platforms for the profiling of glycerophospholipid (GPL) species in esophageal cancer tissue. In particular, we studied the similarities and differences in the range of GPLs detected and the congruency of their relative abundances as detected by each analytical platform. The main differences between mass spectra of the two modalities were found to be associated with the variance in adduct formation of common GPLs, rather than the presence of different GPL species. Phosphatidylcholines as formate adducts in UPLC-ESI-MS accounted for the majority of differences in negative ion mode and alkali metal adducts of phosphatidylcholines in DESI-MS for positive ion mode. Comparison of the relative abundance of GPLs, normalized to a common peak, revealed a correlation coefficient of 0.70 ( P < 0.001). The GPL profile detected by DESI-MS is congruent to UPLC-ESI-MS, which reaffirms the role of DESI-MS for lipidomic profiling and a potential premise for quantification.

  8. Advantages of Molecular Weight Identification during Native MS Screening.

    PubMed

    Khan, Ahad; Bresnick, Anne; Cahill, Sean; Girvin, Mark; Almo, Steve; Quinn, Ronald

    2018-05-09

    Native mass spectrometry detection of ligand-protein complexes allowed rapid detection of natural product binders of apo and calcium-bound S100A4 (a member of the metal binding protein S100 family), T cell/transmembrane, immunoglobulin (Ig), and mucin protein 3, and T cell immunoreceptor with Ig and ITIM (immunoreceptor tyrosine-based inhibitory motif) domains precursor protein from extracts and fractions. Based on molecular weight common hits were detected binding to all four proteins. Seven common hits were identified as apigenin 6- C - β - D -glucoside 8- C - α - L -arabinoside, sweroside, 4',5-dihydroxy-7-methoxyflavanone-6- C -rutinoside, loganin acid, 6- C -glucosylnaringenin, biochanin A 7- O -rutinoside and quercetin 3- O -rutinoside. Mass guided isolation and NMR identification of hits confirmed the mass accuracy of the ligand in the ligand-protein MS complexes. Thus, molecular weight ID from ligand-protein complexes by electrospray ionization Fourier transform mass spectrometry allowed rapid dereplication. Native mass spectrometry using electrospray ionization Fourier transform mass spectrometry is a tool for dereplication and metabolomics analysis. Georg Thieme Verlag KG Stuttgart · New York.

  9. Determination of benzothiazole and benzotriazole derivates in tire and clothing textile samples by high performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Avagyan, Rozanna; Sadiktsis, Ioannis; Thorsén, Gunnar; Östman, Conny; Westerholm, Roger

    2013-09-13

    A high performance liquid chromatography-tandem mass spectrometry method utilizing electrospray ionization in positive and negative mode has been developed for the separation and detection of benzothiazole and benzotriazole derivates. Ultra-sonication assisted solvent extraction of these compounds has also been developed and the overall method demonstrated on a selected clothing textile and an automobile tire sample. Matrix effects and extraction recoveries, as well as linearity and limits of detection have been evaluated. The calibration curves spanned over more than two orders of magnitude with coefficients of correlation R(2)>0.99 and the limits of detection and the limits of quantification were in the range 1.7-58pg injected and 18-140pg/g, respectively. The extraction recoveries ranged between 69% and 102% and the matrix effects between 75% and 101%. Benzothiazole and benzotriazole derivates were determined in the textile sample and benzothiazole derivatives determined in the tire sample with good analytical performance. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Determination of phenylurea herbicides in water samples using online sorptive preconcentration and high-performance liquid chromatography with UV or electrospray mass spectrometric detection.

    PubMed

    Baltussen, E; Snijders, H; Janssen, H G; Sandra, P; Cramers, C A

    1998-04-10

    A recently developed method for the extraction of organic micropollutants from aqueous samples based on sorptive enrichment in columns packed with 100% polydimethylsiloxane (PDMS) particles was coupled on-line with HPLC analysis. The sorptive enrichment procedure originally developed for relatively nonpolar analytes was used to preconcentrate polar phenylurea herbicides from aqueous samples. PDMS extraction columns of 5, 10 and 25 cm were used to extract the herbicides from distilled, tap and river water samples. A model that allows prediction of retention and breakthrough volumes is presented. Despite the essentially apolar nature of the PDMS material, it is possible to concentrate sample volumes up to 10 ml on PDMS cartridges without losses of the most polar analyte under investigation, fenuron. For less polar analytes significantly larger sample volumes can be applied. Since standard UV detection does not provide adequate selectivity for river water samples, an electrospray (ES)-MS instrument was used to determine phenylurea herbicides in a water sample from the river Dommel. Methoxuron was present at a level of 80 ng/l. The detection limit of the current set-up, using 10 ml water samples and ES-MS detection is 10 ng/l in river water samples. Strategies for further improvement of the detection limits are identified.

  11. Challenges for Detecting Valproic Acid in a Nontargeted Urine Drug Screening Method.

    PubMed

    Pope, Jeffrey D; Black, Marion J; Drummer, Olaf H; Schneider, Hans G

    2017-08-01

    Valproic acid (VPA) is a widely prescribed medicine, and acute toxicity is possible. As such, it should be included in any nontargeted urine drug screening method. In many published liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) methods, VPA is usually measured using a pseudo-multiple reaction monitoring (MRM) transition. We investigate a simple ultra-high-performance liquid chromatography-quadrupole time-of-flight (QTof) approach to detect the presence of VPA with more confidence. Three commercially sourced VPA metabolites were characterized and added to a nontargeted high-resolution MS urine drug screening method. All analyses were performed on a Waters Xevo G2-XS LC-QTof in negative electrospray ionization mode. The mass detector was operated in MS mode, and data were processed with UNIFI software. Sixty-eight patient urine samples, which were previously identified by a well-established gas chromatography-MS method as containing VPA, were analyzed on the Waters Xevo G2-XS LC-QTof, to validate this approach. VPA metabolite standards were characterized, and their detection data were added to the broad drug screening library. VPA metabolites were readily detectable in the urine of patients taking VPA. The inclusion of characterized VPA metabolites provides a simple and reliable method enabling the detection of VPA in nontargeted urine drug screening.

  12. ANALYSIS OF HYDROPONIC FERTILIZER MATRIXES FOR PERCHLORATE: COMPARISON OF ANALYTICAL TECHNIQUES

    EPA Science Inventory

    Seven retail hydroponic nitrate fertilizer products, two liquid and five solid, were comparatively analyzed for the perchlorate anion (ClO4-) by ion chromatography (IC) with suppressed conductivity detection, complexation electrospray ionization mass spectrometry (cESI-MS), norma...

  13. Molecular selectivity of brown carbon chromophores.

    PubMed

    Laskin, Julia; Laskin, Alexander; Nizkorodov, Sergey A; Roach, Patrick; Eckert, Peter; Gilles, Mary K; Wang, Bingbing; Lee, Hyun Ji Julie; Hu, Qichi

    2014-10-21

    Complementary methods of high-resolution mass spectrometry and microspectroscopy were utilized for molecular analysis of secondary organic aerosol (SOA) generated from ozonolysis of two structural monoterpene isomers: D-limonene SOA (LSOA) and α-pinene SOA (PSOA). The LSOA compounds readily formed adducts with Na(+) under electrospray ionization conditions, with only a small fraction of compounds detected in the protonated form. In contrast, a significant fraction of PSOA compounds appeared in the protonated form because of their increased molecular rigidity. Laboratory simulated aging of LSOA and PSOA, through conversion of carbonyls into imines mediated by NH3 vapors in humid air, resulted in selective browning of the LSOA sample, while the PSOA sample remained white. Comparative analysis of the reaction products in the aged LSOA and PSOA samples provided insights into chemistry relevant to formation of brown carbon chromophores. A significant fraction of carbonyl-imine conversion products with identical molecular formulas was detected in both samples. This reflects the high level of similarity in the molecular composition of these two closely related SOA materials. Several highly conjugated products were detected exclusively in the brown LSOA sample and were identified as potential chromophores responsible for the observed color change. The majority of the unique products in the aged LSOA sample with the highest number of double bonds contain two nitrogen atoms. We conclude that chromophores characteristic of the carbonyl-imine chemistry in LSOA are highly conjugated oligomers of secondary imines (Schiff bases) present at relatively low concentrations. Formation of this type of conjugated compounds in PSOA is hindered by the structural rigidity of the α-pinene oxidation products. Our results suggest that the overall light-absorbing properties of SOA may be determined by trace amounts of strong brown carbon chromophores.

  14. Sampling and analyte enrichment strategies for ambient mass spectrometry.

    PubMed

    Li, Xianjiang; Ma, Wen; Li, Hongmei; Ai, Wanpeng; Bai, Yu; Liu, Huwei

    2018-01-01

    Ambient mass spectrometry provides great convenience for fast screening, and has showed promising potential in analytical chemistry. However, its relatively low sensitivity seriously restricts its practical utility in trace compound analysis. In this review, we summarize the sampling and analyte enrichment strategies coupled with nine modes of representative ambient mass spectrometry (desorption electrospray ionization, paper vhspray ionization, wooden-tip spray ionization, probe electrospray ionization, coated blade spray ionization, direct analysis in real time, desorption corona beam ionization, dielectric barrier discharge ionization, and atmospheric-pressure solids analysis probe) that have dramatically increased the detection sensitivity. We believe that these advances will promote routine use of ambient mass spectrometry. Graphical abstract Scheme of sampling stretagies for ambient mass spectrometry.

  15. Determination of the phenoxyacid herbicides MCPA, mecoprop and 2,4-D in kidney tissue using liquid chromatography with electrospray tandem mass spectrometry.

    PubMed

    Charlton, Andrew J A; Stuckey, Vicki; Sykes, Mark D

    2009-06-01

    An analytical method was developed to determine the phenoxyacid herbicides 2,4-D, MCPA and mecoprop in kidney tissue from animals where poisoning is suspected. Samples were Soxhlet extracted using diethyl ether and the extracts cleaned-up using anion exchange solid phase extraction cartridges. Analysis was performed using liquid chromatography with negative-ion electrospray tandem mass spectrometry (LC-MS/MS). The method was evaluated by analysing control kidney samples fortified at 1 and 5 mg/kg. Mean recoveries ranged from 82 to 93% with relative standard deviations from 3.2 to 19%. The limit of detection was estimated to be 0.02 mg/kg.

  16. Highly sensitive derivatization reagents possessing positively charged structures for the determination of oligosaccharides in glycoproteins by high-performance liquid chromatography electrospray ionization tandem mass spectrometry.

    PubMed

    Min, Jun Zhe; Nagai, Keisuke; Shi, Qing; Zhou, Wenjun; Todoroki, Kenichiro; Inoue, Koichi; Lee, Yong-Ill; Toyo'oka, Toshimasa

    2016-09-23

    We have developed three kinds of novel derivatization reagents (4-CEBTPP, 4-CBBTPP, 5-COTPP) with triphenylphosphine (TPP) as a basic structure carrying a permanent positive charge for resolution of the oligosaccharides in glycoprotein using high-performance liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). The synthesized reagents reacted with the sialylglycosylamine of the sialylglycopeptide after treatment by PNGase F. The final derivatives were analyzed by ESI-MS and sensitively detected in the selected reaction monitoring (SRM) mode. Furthermore, the limits of detection (S/N=3) on the SRM chromatograms were at the fmol level (30fmol). Therefore, we used the limit of detection of the reagent products detected by the SRM and evaluated the utility of each reagent. Among the reagents, the positively charged 4-CEBTPP derivative's peak area was the highest; 4-CEBTPP with a positively charged structure showed about a 20 times greater sensitivity for the glycosylamine of the SGP product compared to the conventional fluorescence reagent, Fmoc-Cl. In addition, various fragment ions based on the carbohydrate units also appeared in the MS/MS spectra. Among the fragment ions, m/z 627.37 (CE=40eV) corresponding to 4-CEBTPP-GlcNAc and m/z 120.09 (CE=100eV) corresponding to 4-CEBTPP are the most important ones for identifying the oligosaccharide. 4-CEBTPP-SGA was easily identified by the selected-ion chromatogram in the product ion scan (m/z 120.09) and in the precursor ion scan (m/z 627.37) by MS/MS detection. The derivatized analytes have a high ionization efficiency and they are detected with a high sensitivity in the electrospray ionization. The novel derivatization reagent with a multi-function provided a higher sensitivity for the oligosaccharide analysis, as well as a better specificity and feasibility. Furthermore, several oligosaccharides in fetuin and ribonuclease B were successfully identified by the proposed procedure. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Optical architecture design for detection of absorbers embedded in visceral fat.

    PubMed

    Francis, Robert; Florence, James; MacFarlane, Duncan

    2014-05-01

    Optically absorbing ducts embedded in scattering adipose tissue can be injured during laparoscopic surgery. Non-sequential simulations and theoretical analysis compare optical system configurations for detecting these absorbers. For absorbers in deep scattering volumes, trans-illumination is preferred instead of diffuse reflectance. For improved contrast, a scanning source with a large area detector is preferred instead of a large area source with a pixelated detector.

  18. Optical architecture design for detection of absorbers embedded in visceral fat

    PubMed Central

    Francis, Robert; Florence, James; MacFarlane, Duncan

    2014-01-01

    Optically absorbing ducts embedded in scattering adipose tissue can be injured during laparoscopic surgery. Non-sequential simulations and theoretical analysis compare optical system configurations for detecting these absorbers. For absorbers in deep scattering volumes, trans-illumination is preferred instead of diffuse reflectance. For improved contrast, a scanning source with a large area detector is preferred instead of a large area source with a pixelated detector. PMID:24877008

  19. Analysis of Compounds Dissolved in Nonpolar Solvents by Electrospray Ionization on Conductive Nanomaterials

    NASA Astrophysics Data System (ADS)

    Xia, Bing; Gao, Yuanji; Ji, Baocheng; Ma, Fengwei; Ding, Lisheng; Zhou, Yan

    2018-03-01

    Electrospray ionization mass spectrometry (ESI-MS) technique has limitations in analysis of compounds that are dissolved in nonpolar solvents. In this study, ambient ionization of compounds in solvents that are not "friendly" to electrospray ionization, such as n-hexane, is achieved by conductive nanomaterials spray ionization (CNMSI) on nanomaterial emitters, including carbon nanotubes paper and mesodendritic silver covered metal, which applies high voltages to emitters made of these materials without the assistance of polar solvents. Although the time intensity curves (TIC) commonly vary from 4.5% to 23.7% over analyses, protonated molecular ions were found to be the most abundant species, demonstrating good reproducibility of the technique in terms of ionized species. Higher mass spectrometric responses are observed in analyzing nonpolar systems than polar systems. 2-Methoxyacetophenone, 4-methylacetophenone, benzothiazole, quinolone, and cycloheptanone as low as 2 pg in n-hexane can be directly detected using the developed method. The developed technique expands the analysis capability of ESI-MS for direct, online analysis of nonpolar systems, such as low polarity extracts, normal phase liquid chromatography eluates, and synthetic mixtures. [Figure not available: see fulltext.

  20. Electrospray ionization from a gap with adjustable width.

    PubMed

    Ek, Patrik; Sjödahl, Johan; Roeraade, Johan

    2006-01-01

    In this paper, we present a new concept for electrospray ionization mass spectrometry, where the sample is applied in a gap which is formed between the edges of two triangular-shaped tips. The size of the spray orifice can be changed by varying the gap width. The tips were fabricated from polyethylene terephthalate film with a thickness of 36 microm. To improve the wetting of the gap and sample confinement, the edges of the tips forming the gap were hydrophilized by means of silicon dioxide deposition. Electrospray was performed with gap widths between 1 and 36 microm and flow rates down to 75 nL/min. The gap width could be adjusted in situ during the mass spectrometry experiments and nozzle clogging could be managed by simply widening the gap. Using angiotensin I as analyte, the signal-to-noise ratio increased as the gap width was decreased, and a shift towards higher charge states was observed. The detection limit for angiotensin I was in the low nM range. Copyright (c) 2006 John Wiley & Sons, Ltd.

  1. Mass spectrometry of rhenium complexes: a comparative study by using LDI-MS, MALDI-MS, PESI-MS and ESI-MS.

    PubMed

    Petroselli, Gabriela; Mandal, Mridul Kanti; Chen, Lee Chuin; Ruiz, Gustavo T; Wolcan, Ezequiel; Hiraoka, Kenzo; Nonami, Hiroshi; Erra-Balsells, Rosa

    2012-03-01

    A group of rhenium (I) complexes including in their structure ligands such as CF(3)SO(3)-, CH(3)CO(2)-, CO, 2,2'-bipyridine, dipyridil[3,2-a:2'3'-c]phenazine, naphthalene-2-carboxylate, anthracene-9-carboxylate, pyrene-1-carboxylate and 1,10-phenanthroline have been studied for the first time by mass spectrometry. The probe electrospray ionization (PESI) is a technique based on electrospray ionization (ESI) that generates electrospray from the tip of a solid metal needle. In this work, mass spectra for organometallic complexes obtained by PESI were compared with those obtained by classical ESI and high flow rate electrospray ionization assisted by corona discharge (HF-ESI-CD), an ideal method to avoid decomposition of the complexes and to induce their oxidation to yield intact molecular cation radicals in gas state [M](+·) and to produce their reduction yielding the gas species [M](-·). It was found that both techniques showed in general the intact molecular ions of the organometallics studied and provided additional structure characteristic diagnostic fragments. As the rhenium complexes studied in the present work showed strong absorption in the UV-visible region, particularly at 355 nm, laser desorption ionization (LDI) mass spectrometry experiments could be conducted. Although intact molecular ions could be detected in a few cases, LDI mass spectra showed diagnostic fragments for characterization of the complexes structure. Furthermore, matrix-assisted laser desorption ionization (MALDI) mass spectra were obtained. Nor-harmane, a compound with basic character, was used as matrix, and the intact molecular ions were detected in two examples, in negative ion mode as the [M](-·) species. Results obtained with 2-[(2E)-3-(4-tert-buthylphenyl)-2-methylprop-2-enylidene] malononitrile (DCTB) as matrix are also described. LDI experiments provided more information about the rhenium complex structures than did the MALDI ones. Copyright © 2012 John Wiley & Sons, Ltd.

  2. Direct Detection of Pharmaceuticals and Personal Care Products from Aqueous Samples with Thermally-Assisted Desorption Electrospray Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Campbell, Ian S.; Ton, Alain T.; Mulligan, Christopher C.

    2011-07-01

    An ambient mass spectrometric method based on desorption electrospray ionization (DESI) has been developed to allow rapid, direct analysis of contaminated water samples, and the technique was evaluated through analysis of a wide array of pharmaceutical and personal care product (PPCP) contaminants. Incorporating direct infusion of aqueous sample and thermal assistance into the source design has allowed low ppt detection limits for the target analytes in drinking water matrices. With this methodology, mass spectral information can be collected in less than 1 min, consuming ~100 μL of total sample. Quantitative ability was also demonstrated without the use of an internal standard, yielding decent linearity and reproducibility. Initial results suggest that this source configuration is resistant to carryover effects and robust towards multi-component samples. The rapid, continuous analysis afforded by this method offers advantages in terms of sample analysis time and throughput over traditional hyphenated mass spectrometric techniques.

  3. Acquiring Structural Information on Virus Particles with Charge Detection Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Keifer, David Z.; Motwani, Tina; Teschke, Carolyn M.; Jarrold, Martin F.

    2016-06-01

    Charge detection mass spectrometry (CDMS) is a single-molecule technique particularly well-suited to measuring the mass and charge distributions of heterogeneous, MDa-sized ions. In this work, CDMS has been used to analyze the assembly products of two coat protein variants of bacteriophage P22. The assembly products show broad mass distributions extending from 5 to 15 MDa for A285Y and 5 to 25 MDa for A285T coat protein variants. Because the charge of large ions generated by electrospray ionization depends on their size, the charge can be used to distinguish hollow shells from more compact structures. A285T was found to form T = 4 and T = 7 procapsids, and A285Y makes a small number of T = 3 and T = 4 procapsids. Owing to the decreased stability of the A285Y and A285T particles, chemical cross-linking was required to stabilize them for electrospray CDMS. Graphical Abstract[Figure not available: see fulltext.

  4. Glycan profiling of monoclonal antibodies using zwitterionic-type hydrophilic interaction chromatography coupled with electrospray ionization mass spectrometry detection.

    PubMed

    Mauko, Lea; Nordborg, Anna; Hutchinson, Joseph P; Lacher, Nathan A; Hilder, Emily F; Haddad, Paul R

    2011-01-15

    We present a new method for the analysis of glycans enzymatically released from monoclonal antibodies (MAbs) employing a zwitterionic-type hydrophilic interaction chromatography (ZIC-HILIC) column coupled with electrospray ionization mass spectrometry (ESI-MS). Both native and reduced glycans were analyzed, and the developed procedure was compared with a standard HILIC procedure used in the pharmaceutical industry whereby fluorescent-labeled glycans are analyzed using a TSK Amide-80 column coupled with fluorescence detection. The separation of isobaric alditol oligosaccharides present in monoclonal antibodies and ribonuclease B is demonstrated, and ZIC-HILIC is shown to have good capability for structural recognition. Glycan profiles obtained with the ZIC-HILIC column and ESI-MS provided detailed information on MAb glycosylation, including identification of some less abundant glycan species, and are consistent with the profiles generated with the standard procedure. This new ZIC-HILIC method offers a simpler and faster approach for glycosylation analysis of therapeutic antibodies. Copyright © 2010 Elsevier Inc. All rights reserved.

  5. Analysis of the extracts of Isatis tinctoria by new analytical approaches of HPLC, MS and NMR.

    PubMed

    Zhou, Jue; Qu, Fan

    2011-01-01

    The methods of extraction, separation and analysis of alkaloids and indole glucosinolates (GLs) ofIsatis tinctoria were reviewed. Different analytical approaches such as High-pressure Liquid Chromatography (HPLC), Liquid Chromatography with Electrospray Ionization Mass Spectrometry (LC/ESI/MS), Electrospray Ionization Time-Of-Flight Mass Spectrometry (ESI-TOF-MS), and Nuclear Magnetic Resonance (NMR) were used to validate and identity of these constituents. These methods provide rapid separation, identification and quantitative measurements of alkaloids and GLs of Isatis tinctoria. By connection with different detectors to HPLC such as PDA, ELSD, ESI- and APCI-MS in positive and negative ion modes, complicated compounds could be detected with at least two independent detection modes. The molecular formula can be derived in a second step of ESI-TOF-MS data. But for some constituents, UV and MS cannot provide sufficient structure identification. After peak purification, NMR by semi-preparative HPLC can be used as a complementary method.

  6. Direct detection of pharmaceuticals and personal care products from aqueous samples with thermally-assisted desorption electrospray ionization mass spectrometry.

    PubMed

    Campbell, Ian S; Ton, Alain T; Mulligan, Christopher C

    2011-07-01

    An ambient mass spectrometric method based on desorption electrospray ionization (DESI) has been developed to allow rapid, direct analysis of contaminated water samples, and the technique was evaluated through analysis of a wide array of pharmaceutical and personal care product (PPCP) contaminants. Incorporating direct infusion of aqueous sample and thermal assistance into the source design has allowed low ppt detection limits for the target analytes in drinking water matrices. With this methodology, mass spectral information can be collected in less than 1 min, consuming ~100 μL of total sample. Quantitative ability was also demonstrated without the use of an internal standard, yielding decent linearity and reproducibility. Initial results suggest that this source configuration is resistant to carryover effects and robust towards multi-component samples. The rapid, continuous analysis afforded by this method offers advantages in terms of sample analysis time and throughput over traditional hyphenated mass spectrometric techniques.

  7. Electrospray ionisation mass spectrometry facilitates detection of fibrinogen (Bbeta 14 Arg --> Cys) mutation in a family with thrombosis.

    PubMed

    Brennan, S O; Hammonds, B; Spearing, R; George, P M

    1997-12-01

    We report the first direct detection of a fibrinogen mutation by electrospray ionisation mass spectrometry. The propositus, from a family with a history of thrombosis, came to attention after a pulmonary embolism subsequent to a spontaneous abortion. Prolonged thrombin (41 s) and reptilase times (26 s) together with an impairment of fibrinopeptide B release suggested a mutation at the thrombin cleavage site of the Bbeta chain. Direct mass analysis of purified fibrin chains from a thrombin induced clot showed that 50% of the Bbeta chains remained uncleaved. The measured mass of the mono sialo isoform of this uncleaved chain was 54150 Da, compared to a value of 54198 Da for normal Bbeta chains. This decrease of 48 Da in the intact protein is indicative of either a Bbeta 14 Arg to Cys, or Arg to Leu substitution. Heterozygosity for the Bbeta 14 Arg --> Cys mutation was verified by PCR amplification and DNA sequence analysis.

  8. Fast quantitative detection of cocaine in beverages using nanoextractive electrospray ionization tandem mass spectrometry.

    PubMed

    Hu, Bin; Peng, Xuejiao; Yang, Shuiping; Gu, Haiwei; Chen, Huanwen; Huan, Yanfu; Zhang, Tingting; Qiao, Xiaolin

    2010-02-01

    Without any sample pretreatment, effervescent beverage fluids were manually sprayed into the primary ion plume created by using a nanoelectrospray ionization source for direct ionization, and the analyte ions of interest were guided into an ion trap mass spectrometer for tandem mass analysis. Functional ingredients (e.g., vitamins, taurine, and caffeine, etc.) and spiked impurity (e.g., cocaine) in various beverages, such as Red Bull energy drink, Coco-cola, and Pepsi samples were rapidly identified within 1.5 s. The limit of detection was found to be 7-15 fg (S/N = 3) for cocaine in different samples using the characteristic fragment (m/z 150) observed in the MS(3) experiments. Typical relative standard deviation and recovery of this method were 6.9%-8.6% and 104%-108% for direct analysis of three actual samples, showing that nanoextractive electrospray ionization tandem mass spectrometry is a useful technique for fast screening cocaine presence in beverages. 2010. Published by Elsevier Inc.

  9. Improving N-Glycan Coverage using HPLC-MS with Electrospray Ionization at Subambient Pressure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marginean, Ioan; Kronewitter, Scott R.; Moore, Ronald J.

    Human serum glycan profiling with mass spectrometry (MS) has been employed to study several disease conditions and is demonstrating promise for e.g. clinical biomarker discovery. However, the poor glycan ionization efficiency and the large dynamic range of glycan concentrations in human sera hinder comprehensive profiling. In particular, large glycans are problematic because they are present at low concentrations and prone to fragmentation. Here we show that the sub-ambient pressure ionization with nanoelectrospray (SPIN)-MS can expand the serum glycome profile when compared with the conventional atmospheric pressure electrospray ionization (ESI)-MS with a heated capillary inlet. Notably, the ions generated by themore » SPIN interface were observed at higher charge states for 50% of the annotated glycans. Out of a total of 130 detected glycans, 34 were only detected with the SPIN-MS, resulting in improved coverage of glycan families as well as of glycans with larger numbers of labile monosaccharides.« less

  10. Demise of Polymerase Chain Reaction/Electrospray Ionization-Mass Spectrometry as an Infectious Diseases Diagnostic Tool.

    PubMed

    Özenci, Volkan; Patel, Robin; Ullberg, Måns; Strålin, Kristoffer

    2018-01-18

    Although there are several US Food and Drug Administration (FDA)-approved/cleared molecular microbiology diagnostics for direct analysis of patient samples, all are single target or panel-based tests. There is no FDA-approved/cleared diagnostic for broad microbial detection. Polymerase chain reaction (PCR)/electrospray ionization-mass spectrometry (PCR/ESI-MS), commercialized as the IRIDICA system (Abbott) and formerly PLEX-ID, had been under development for over a decade and had become CE-marked and commercially available in Europe in 2014. Capable of detecting a large number of microorganisms, it was under review at the FDA when, in April 2017, Abbott discontinued it. This turn of events represents not only the loss of a potential diagnostic tool for infectious diseases but may be a harbinger of similar situations with other emerging and expensive microbial diagnostics, especially genomic tests. © The Author(s) 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  11. Chemical analysis of raw and processed Fructus arctii by high-performance liquid chromatography/diode array detection-electrospray ionization-mass spectrometry

    PubMed Central

    Qin, Kunming; Liu, Qidi; Cai, Hao; Cao, Gang; Lu, Tulin; Shen, Baojia; Shu, Yachun; Cai, Baochang

    2014-01-01

    Background: In traditional Chinese medicine (TCM), raw and processed herbs are used to treat the different diseases. Fructus Arctii, the dried fruits of Arctium lappa l. (Compositae), is widely used in the TCM. Stir-frying is the most common processing method, which might modify the chemical compositions in Fructus Arctii. Materials and Methods: To test this hypothesis, we focused on analysis and identification of the main chemical constituents in raw and processed Fructus Arctii (PFA) by high-performance liquid chromatography/diode array detection-electrospray ionization-mass spectrometry. Results: The results indicated that there was less arctiin in stir-fried materials than in raw materials. however, there were higher levels of arctigenin in stir-fried materials than in raw materials. Conclusion: We suggest that arctiin reduced significantly following the thermal conversion of arctiin to arctigenin. In conclusion, this finding may shed some light on understanding the differences in the therapeutic values of raw versus PFA in TCM. PMID:25422559

  12. Broad-Range Detection of Microorganisms Directly from Bronchoalveolar Lavage Specimens by PCR/Electrospray Ionization-Mass Spectrometry

    PubMed Central

    Ullberg, Måns; Lüthje, Petra; Mölling, Paula; Strålin, Kristoffer

    2017-01-01

    The clinical demand on rapid microbiological diagnostic is constantly increasing. PCR coupled to electrospray ionization-mass spectrometry, PCR/ESI-MS, offers detection and identification of over 750 bacteria and Candida species directly from clinical specimens within 6 hours. In this study, we investigated the clinical performance of the IRIDICA BAC LRT Assay for detection of bacterial pathogens in 121 bronchoalveolar lavage (BAL) samples that were received consecutively at our bacterial laboratory for BAL culture. Commensal or pathogenic microorganisms were detected in 118/121 (98%) BAL samples by PCR/ESI-MS, while in 104/121 (86%) samples by routine culture (P<0.01). Detection of potentially pathogenic microorganisms by PCR/ESI-MS was evaluated in comparison with conventional culture-based or molecular methods. The agreement between positive findings was overall good. Most Staphylococcus aureus-positive PCR/ESI-MS results were confirmed by culture or species-specific PCR (27/33, 82%). The identity of Streptococcus pneumoniae could however be confirmed for only 6/17 (35%) PCR/ESI-MS-positive samples. Non-cultivable and fastidious pathogens, which were not covered by standard culture procedures were readily detected by PCR/ESI-MS, including Legionella pneumophila, Bordetella pertussis, Norcadia species and Mycoplasma pneumoniae. In conclusion, PCR/ESI-MS detected a broad range of potential pathogens with equal or superior sensitivity compared to conventional methods within few hours directly from BAL samples. This novel method might thus provide a relevant tool for diagnostics in critically ill patients. PMID:28085931

  13. High-performance liquid chromatography analysis of plant saponins: An update 2005-2010

    PubMed Central

    Negi, Jagmohan S.; Singh, Pramod; Pant, Geeta Joshi Nee; Rawat, M. S. M.

    2011-01-01

    Saponins are widely distributed in plant kingdom. In view of their wide range of biological activities and occurrence as complex mixtures, saponins have been purified and separated by high-performance liquid chromatography using reverse-phase columns at lower wavelength. Mostly, saponins are not detected by ultraviolet detector due to lack of chromophores. Electrospray ionization mass spectrometry, diode array detector , evaporative light scattering detection, and charged aerosols have been used for overcoming the detection problem of saponins. PMID:22303089

  14. Enhanced direct ambient analysis by differential mobility-filtered desorption electrospray ionization-mass spectrometry.

    PubMed

    Galhena, Asiri S; Harris, Glenn A; Kwasnik, Mark; Fernández, Facundo M

    2010-11-15

    Desorption electrospray ionization (DESI) is rapidly becoming established as one of the most powerful ionization techniques allowing direct surface analysis by mass spectrometry (MS) in the ambient environment. DESI provides a significant number of unique analytical capabilities for a broad range of applications, both quantitative and qualitative in nature including biological tissue imaging, pharmaceutical quality control, in vivo analysis, proteomics, metabolomics, forensics, and explosives detection. Despite its growing adoption as a powerful high throughput analysis tool, DESI-MS analysis at trace levels often suffers from background chemical interferences generated during the electrospray ionization processes. In order to improve sensitivity and selectivity, a differential mobility (DM) ion separation cell was successfully interfaced to a custom-built DESI ion source. This new hybrid platform can be operated in two modes: the "DM-off" mode for standard DESI analysis and "DM-on mode" where DESI-generated ions are detected after discrimination by the differential mobility cell. The performance of the DESI-DM-MS platform was tested with several samples typically amenable to DESI analysis, including counterfeit pharmaceuticals and binary mixtures of isobaric chemicals of importance in the pharmaceutical and food industries. In the DM-on mode, DESI-MS signal-to-noise ratios were improved by 70-190% when compared to the DM-off mode. Also, the addition of the DM cell enabled selective in-source ion activation of specific DESI-generated precursor ions, providing tandem MS-like spectra in a single stage mass spectrometer.

  15. A Comparison of Alternating Current and Direct Current Electrospray Ionization for Mass Spectrometry

    PubMed Central

    Sarver, Scott A.; Gartner, Carlos A.; Chetwani, Nishant; Go, David B.; Dovichi, Norman J.

    2014-01-01

    A series of studies comparing the performance of alternating current electrospray ionization (AC ESI) mass spectrometry (MS) and direct current electrospray ionization (DC ESI) MS has been conducted, exploring the absolute signal intensity and signal-to-background ratios produced by both methods using caffeine and a model peptide as targets. Because the high-voltage AC signal was more susceptible to generating gas discharges, the operating voltage range of AC ESI was significantly smaller than that for DC ESI, such that the absolute signal intensities produced by DC ESI at peak voltages were 1 - 2 orders of magnitude greater than those for AC ESI. Using an electronegative nebulizing gas, sulfur hexafluoride (SF6), instead of nitrogen (N2) increased the operating range of AC ESI by ~50%, but did not appreciably improve signal intensities. While DC ESI generated far greater signal intensities, both ionization methods produced comparable signal-to-background noise, with AC ESI spectra appearing qualitatively cleaner. A quantitative calibration analysis was performed for two analytes, caffeine and the peptide MRFA. AC ESI utilizing SF6 outperforms all other techniques for the detection of MRFA, producing chromatographic limits of detection nearly one order of magnitude lower than that of DC ESI utilizing N2, and one half that of DC ESI utilizing SF6. However, DC ESI outperforms AC ESI for the analysis of caffeine, indicating improvements in spectral quality may benefit certain compounds, or classes of compounds, on an individual basis. PMID:24464359

  16. Comparison and characterization of soybean and sunflower lecithins used for chocolate production by high-performance thin-layer chromatography with fluorescence detection and electrospray mass spectrometry.

    PubMed

    Krüger, Stephanie; Bürmann, Laura; Morlock, Gertrud E

    2015-03-25

    The scarce availability of nongenetically modified soybeans on the world market represents a growing problem for food manufacturers. Hence, in this study the effects of substituting soybean with sunflower lecithin were investigated with regard to chocolate production. The glycerophospholipid pattern of the different lecithin samples was investigated by high-performance thin-layer chromatography fluorescence detection (HPTLC-FLD) and by HPTLC-positive ion electrospray ionization mass spectrometry (ESI(+)-MS) via the TLC-MS Interface and by scanning HPTLC-matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOFMS). Especially, the contents of phosphatidylcholine (PC) and phosphatidylethanolamine (PE) were of interest due to the influencing effects of these two glycerophospholipids on the rheological parameters of chocolate production. The lecithin substitution led to only slight differences in the rheological parameters of milk and dark chocolate. Limits of detection (LODs) and limits of quantification (LOQs) of seven glycerophospholipids were studied for three detection modes. Mean LODs ranged from 8 to 40 mg/kg for HPTLC-FLD and, using a single-quadrupole MS, from 10 to 280 mg/kg for HPTLC-ESI(+)-MS as well as from 15 to 310 mg/kg for HPTLC-FLD-ESI(+)-MS recorded after derivatization with the primuline reagent.

  17. DMSO Assisted Electrospray Ionization for the Detection of Small Peptide Hormones in Urine by Dilute-and-Shoot-Liquid-Chromatography-High Resolution Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Judák, Péter; Grainger, Janelle; Goebel, Catrin; Van Eenoo, Peter; Deventer, Koen

    2017-08-01

    The mobile phase additive (DMSO) has been described as a useful tool to enhance electrospray ionization (ESI) of peptides and proteins. So far, this technique has mainly been used in proteomic/peptide research, and its applicability in a routine clinical laboratory setting (i.e., doping control analysis) has not been described yet. This work provides a simple, easy to implement screening method for the detection of doping relevant small peptides (GHRPs, GnRHs, GHS, and vasopressin-analogues) with molecular weight less than 2 kDa applying DMSO in the mobile phase. The gain in sensitivity was sufficient to inject the urine samples after a 2-fold dilution step omitting a time consuming sample preparation. The employed analytical procedure was validated for the qualitative determination of 36 compounds, including 13 metabolites. The detection limits (LODs) ranged between 50 and 1000 pg/mL and were compliant with the 2 ng/mL minimum detection level required by the World Anti-Doping Agency (WADA) for all the target peptides. To demonstrate the feasibility of the work, urine samples obtained from patients who have been treated with desmopressin or leuprolide and urine samples that have been declared as adverse analytical findings were analyzed.

  18. UPLC-MS/MS determination and gender-related pharmacokinetic study of five active ingredients in rat plasma after oral administration of Eucommia cortex extract.

    PubMed

    Hu, Fangdi; An, Jing; Li, Wen; Zhang, Zijia; Chen, Wenxia; Wang, Changhong; Wang, Zhengtao

    2015-07-01

    Eucommiae cortex (EC), the bark of Eucommia ulmoides Oliv., has been traditionally used to treat many diseases in China for more than 2000 years. The pharmacological effects are primarily attributed to the presence of lignans, iridoids and phenolics, which are main active ingredients in EC. First, to investigate the active ingredients that can be absorbed into the rat plasma according to which ingredients exhibit significant correlation of drug concentration-time curve. Second, to establish an efficient ultra-performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method for simultaneous determination of ingredients absorbed in rat plasma. Finally, to investigate gender effect on the pharmacokinetics of the ingredients absorbed in male and female rats plasma after oral administration with EC extract. 18 ingredients from EC were detected by UPLC-MS/MS, 9 out of 18 ingredients were absorbed into rat plasma. And 5 ingredients exhibit significant correlation of drug concentration-time curve. They were pinoresinol di-O-β-d-glucopyranoside (PDG), geniposide (GE), geniposidic acid (GA), aucubin (AN) and chlorogenic acid (CA). The analytes were extracted from rat plasma via a simple protein precipitation procedure and osalmid was used as the internal standard. Chromatographic separation was achieved on a Waters ACQUITY HSS T3 column (2.1mm×100mm, 1.8μm) using a gradient elution program with acetonitrile and 0.1% formic acid water as the mobile phase, with a flow rate of 0.3mLmin(-1). The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reactions monitoring (MRM) mode in a positive ion mode via electrospray ionization (ESI). The transition monitored were /z 683.00[M+H](+)→235.10 for PDG, / z 389.00[M+H](+)→208.80 for GE, m/z 375.00[M+H](+)→194.79 for GA, m/z 364.00[M+NH4](+)→148.81 for AN, m/z 355.10[M+H](+)→162.84 for CA and m/z 230.03[M+H](+)→120.77 for internal standard. The developed method showed good linearity over a wide concentration range, the lower limits of quantification and higher accuracy and precision for determination of the 5 analytes. Then the method was applied to study the pharmacokinetics in rats, and the results indicated that there were significant differences in pharmacokinetic parameters of the analytes between the male and female rats, and absorptions of these analytes in male group were all significantly higher than those in female group. This study established an efficient, sensitive and selective UPLC-MS/MS method for simultaneous determination of the five ingredients in rat plasma, and it could be successfully applied to the comparative pharmacokinetic studies in male and female rats after oral administration with EC extract. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Classification of Astrocytomas and Oligodendrogliomas from Mass Spectrometry Data Using Sparse Kernel Machines

    PubMed Central

    Huang, Jacob; Gholami, Behnood; Agar, Nathalie Y. R.; Norton, Isaiah; Haddad, Wassim M.; Tannenbaum, Allen R.

    2013-01-01

    Glioma histologies are the primary factor in prognostic estimates and are used in determining the proper course of treatment. Furthermore, due to the sensitivity of cranial environments, real-time tumor-cell classification and boundary detection can aid in the precision and completeness of tumor resection. A recent improvement to mass spectrometry known as desorption electrospray ionization operates in an ambient environment without the application of a preparation compound. This allows for a real-time acquisition of mass spectra during surgeries and other live operations. In this paper, we present a framework using sparse kernel machines to determine a glioma sample’s histopathological subtype by analyzing its chemical composition acquired by desorption electrospray ionization mass spectrometry. PMID:22256188

  20. On-Chip Photothermal Analyte Detection Using Integrated Luminescent Temperature Sensors.

    PubMed

    Pfeiffer, Simon A; Nagl, Stefan

    2017-09-05

    Optical absorbance detection based on attenuated light transmission is limited in sensitivity due to short path lengths in microfluidic and other miniaturized platforms. An alternative is detection using the photothermal effect. Herein we introduce a new kind of photothermal absorbance measurement using integrated luminescent temperature sensor spots inside microfluidic channels. The temperature sensors were photopolymerized inside the channels from NOA 81 UV-curable thiolene prepolymer doped with a tris(1,10-phenanthroline)ruthenium(II) temperature probe. The polymerized sensing structures were as small as 26 ± 3 μm in diameter and displayed a temperature resolution of better than 0.3 K between 20 and 50 °C. The absorbance from 532 nm laser excitation of the food dye Amaranth as a model analyte was quantified using these spots, and the influence of the flow rate, laser power, and concentration was investigated. Calibration yielded a linear relationship between analyte concentration and the temperature signal in the channels. The limit of detection for the azo-dye Amaranth (E123) in this setup was 13 μM. A minimal detectable absorbance of 3.2 × 10 -3 AU was obtained using an optical path length of 125 μm in this initial study. A microreactor with integrated temperature sensors was then employed for an absorbance-based miniaturized nitrite analysis, yielding a detection limit of 26 μM at a total assay time of only 75 s. This technique is very promising for sensitive, and potentially spatially resolved, optical absorbance detection on the micro- and nanoscale.

  1. Characterization of constituents in Stellera chamaejasme L. by rapid-resolution liquid chromatography-diode array detection and electrospray ionization time-of-flight mass spectrometry.

    PubMed

    Zhao, Liang; Lou, Zi-Yang; Zhu, Zhen-Yu; Zhang, Guo-Qing; Chai, Yi-Feng

    2008-01-01

    A reliable and rapid method based on rapid-resolution liquid chromatography-diode array detection (RRLC-DAD) and electrospray ionization time-of-flight mass spectrometry (ESI-TOF/MS) has been developed for the isolation and characterization of multiple constituents in the root of Stellera chamaejasme L., which was extracted by sonication with methanol in an optimized procedure. Separation of the multiple constituents was achieved on an Agilent Zorbax XDB-C18 (50x3.0 mm i.d.; 1.8 microm) column using a gradient elution at a flow rate of 0.4 mL/min. The detection wavelength was 210 nm. Mass spectra were acquired in both positive and negative modes. A formula database of the known chemical constituents in the root of Stellera chamaejasme L. was established by an Agilent software. Twenty-two obvious peaks appeared in the total ion chromatogram and nine of them were characterized by TOF/MS. The RRLC-DAD and ESI-TOF/MS method with ultrasonic extraction would be useful for rapid and effective characterization of chemical constituents in the root of Stellera chamaejasme L. Copyright (c) 2007 John Wiley & Sons, Ltd.

  2. Identification of process related trace level impurities in the actinide decorporation agent 3,4,3-LI(1,2-HOPO): Nozzle–skimmer fragmentation via ESI LC–QTOFMS

    DOE PAGES

    Panyala, Nagender R.; Sturzbecher-Hoehne, Manuel; Abergel, Rebecca J.

    2014-08-12

    We report that 3,4,3-LI(1,2-HOPO) is a chelating ligand and decorporation agent that can remove radioactive lanthanides and actinides from the body. Identification of trace impurities in drug samples is gaining much interest due to their significant influence on drug activity. In this study, trace impurities were detected in manufactured lots of 3,4,3-LI(1,2-HOPO) by a developed method of Liquid Chromatography coupled with photo-diode array UV detection and Electrospray Ionization-Quadrupole Time of Flight Mass spectrometry (LC-QTOFMS), via induced-in-source or collision-induced mass fragmentation (Nozzle-Skimmer Fragmentation). Molecular ions were fragmented within the nozzle-skimmer region of electrospray ionization (ESI) mass spectrometer equipped with a Timemore » of Flight detector. Eight major (detected at levels higher than a 0.1% threshold) and seven minor trace impurities were identified. The respective structures of these impurities were elucidated via analysis of the generated fragment ions using mass fragmentation and elemental composition software. Proposed structures of impurities were further confirmed via isotopic modeling.« less

  3. Rapid and selective determination of multi-sulfonamides by high-performance thin layer chromatography coupled to fluorescent densitometry and electrospray ionization mass detection.

    PubMed

    Chen, Yisheng; Schwack, Wolfgang

    2014-02-28

    In the European Union (EU), sulfonamides are among the most widely administrated groups of antibiotics in animal husbandry. Therefore, monitoring their residues in edible animal tissues plays an important role in the EU food safety framework. In this work, a simple and efficient method for the rapid screening of twelve prior sulfonamides frequently prescribed as veterinary drugs by high-performance thin-layer chromatography (HPTLC) was established. Sample extracts obtained with acetonitrile were tenfold concentrated and applied to HPTLC without any further cleanup. Following separation and fluram derivatization, sensitive and selective quantitation of the analytes can readily be accomplished with fluorescent densitometry. Limits of detection and quantitation were 15-40 and 35-70μg/kg, respectively. Additionally, a confirmative detection by HPTLC-electrospray ionization mass spectrometry (HPTLC-ESI/MS) was optimized, offering straightforward identification of target zones. Therefore, the risk of potential false positive findings can efficiently be reduced. The method was validated to meet the enforced commission regulation (EU) No. 37/2010, regarding different matrix complexities (bovine milk, porcine liver and kidney). Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Online monitoring of chemical reactions by polarization-induced electrospray ionization.

    PubMed

    Meher, Anil Kumar; Chen, Yu-Chie

    2016-09-21

    Polarization-induced electrospray ionization (PI-ESI) is a simple technique for instant generation of gas-phase ions directly from a microliter-sized droplet for mass spectrometric analysis. A sample droplet was placed over a dielectric substrate and in proximity (2-3 mm) to the inlet of a mass spectrometer. Owing to the polarization effect induced by the high electric field provided by the mass spectrometer, the droplet was polarized and the electrospray was generated from the apex of the droplet. The polarization-induced electrospray could last for tens of seconds, which was sufficiently long to monitor fast reactions occurring within few seconds. Thus, we demonstrated the feasibility of using the droplet-based PI-ESI MS for the online monitoring of fast reactions by simply mixing two droplets (5-10 μL) containing reactants on a dielectric substrate placed in front of a mass spectrometer applied with a high voltage (-4500 V). Schiff base reactions and oxidation reactions that can generate intermediates/products within a few seconds were selected as the model reactions. The ionic reaction species generated from intermediates and products can be simultaneously monitored by PI-ESI MS in real time. We also used this approach to selectively detect acetone from a urine sample, in which acetone was derivatized in situ. In addition, the possibility of using this approach for quantitative analysis of acetone from urine samples was examined. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Electrospray ionization mass spectrometry for the hydrolysis complexes of cisplatin: implications for the hydrolysis process of platinum complexes.

    PubMed

    Feifan, Xie; Pieter, Colin; Jan, Van Bocxlaer

    2017-07-01

    Non-enzyme-dependent hydrolysis of the drug cisplatin is important for its mode of action and toxicity. However, up until today, the hydrolysis process of cisplatin is still not completely understood. In the present study, the hydrolysis of cisplatin in an aqueous solution was systematically investigated by using electrospray ionization mass spectrometry coupled to liquid chromatography. A variety of previously unreported hydrolysis complexes corresponding to monomeric, dimeric and trimeric species were detected and identified. The characteristics of the Pt-containing complexes were investigated by using collision-induced dissociation (CID). The hydrolysis complexes demonstrate distinctive and correlative CID characteristics, which provides tools for an informative identification. The most frequently observed dissociation mechanism was sequential loss of NH 3 , H 2 O and HCl. Loss of the Pt atom was observed as the final step during the CID process. The formation mechanisms of the observed complexes were explored and experimentally examined. The strongly bound dimeric species, which existed in solution, are assumed to be formed from the clustering of the parent compound and its monohydrated or dihydrated complexes. The role of the electrospray process in the formation of some of the observed ions was also evaluated, and the electrospray ionization-related cold clusters were identified. The previously reported hydrolysis equilibria were tested and subsequently refined via a hydrolysis study resulting in a renewed mechanistic equilibrium system of cisplatin as proposed from our results. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Metal Cationization Extractive Electrospray Ionization Mass Spectrometry of Compounds Containing Multiple Oxygens

    NASA Astrophysics Data System (ADS)

    Swanson, Kenneth D.; Spencer, Sandra E.; Glish, Gary L.

    2017-06-01

    Extractive electrospray ionization is an ambient ionization technique that allows real-time sampling of liquid samples, including organic aerosols. Similar to electrospray ionization, the composition of the electrospray solvent used in extractive electrospray ionization can easily be altered to form metal cationized molecules during ionization simply by adding a metal salt to the electrospray solvent. An increase in sensitivity is observed for some molecules that are lithium, sodium, or silver cationized compared with the protonated molecule formed in extractive electrospray ionization with an acid additive. Tandem mass spectrometry of metal cationized molecules can also significantly improve the ability to identify a compound. Tandem mass spectrometry of lithium and silver cationized molecules can result in an increase in the number and uniqueness of dissociation pathways relative to [M + H]+. These results highlight the potential for extractive electrospray ionization with metal cationization in analyzing complex aerosol mixtures. [Figure not available: see fulltext.

  7. Metamaterial Absorber Based Multifunctional Sensor Application

    NASA Astrophysics Data System (ADS)

    Ozer, Z.; Mamedov, A. M.; Ozbay, E.

    2017-02-01

    In this study metamaterial based (MA) absorber sensor, integrated with an X-band waveguide, is numerically and experimentally suggested for important application including pressure, density sensing and marble type detecting applications based on rectangular split ring resonator, sensor layer and absorber layer that measures of changing in the dielectric constant and/or the thickness of a sensor layer. Changing of physical, chemical or biological parameters in the sensor layer can be detected by measuring the resonant frequency shifting of metamaterial absorber based sensor. Suggested MA based absorber sensor can be used for medical, biological, agricultural and chemical detecting applications in microwave frequency band. We compare the simulation and experimentally obtained results from the fabricated sample which are good agreement. Simulation results show that the proposed structure can detect the changing of the refractive indexes of different materials via special resonance frequencies, thus it could be said that the MA-based sensors have high sensitivity. Additionally due to the simple and tiny structures it could be adapted to other electronic devices in different sizes.

  8. New phenolic components and chromatographic profiles of green and fermented teas

    USDA-ARS?s Scientific Manuscript database

    A standardized profiling method based on liquid chromatography with diode array and electrospray ionization/mass spectrometric detection (LC-DAD-ESI/MS) was applied to establish the phenolic profiles of 41 green teas and 25 fermented teas. More than 80 phenolic compounds were either identified that ...

  9. A systematic approach to the identification of common hydroxycinnamoylquinic acids in plant materials

    USDA-ARS?s Scientific Manuscript database

    A standardized profiling method based on liquid chromatography with diode array and electrospray ionization/mass spectrometric detection (LC-DAD-ESI/MS) was used to separate and identify the phenolic components of arnica flowers (Arnica montana L.), burdock roots (Artium lappa L.), coffee beans (Cof...

  10. MICROSCALE EXTRACTION OF PERCHLORATE IN DRINKING WATER WITH LOW LEVEL DETECTION BY ELECTROSPRAY-MASS SPECTROMETRY.

    EPA Science Inventory

    Improper treatment and disposal of perchlorate can be an environmental hazard in regions where solid rocket motors are used, tested, or stored. The solubility and mobility of perchlorate lends itself to ground water contamination, and some of these sources are used for drinking ...

  11. Developing analytical approaches to explore the connectionbetween endocrine-active pharmaceuticals in waterto effects in fish

    EPA Science Inventory

    The emphasis of this research project was to develop, and optimize, a solid-phase extraction (SPE) method and high performance liquid chromatography-electrospray ionization- mass spectrometry (LC-MS/MS) method, such that a linkage between the detection of endocrine active pharma...

  12. Ion concentration in micro and nanoscale electrospray emitters.

    PubMed

    Yuill, Elizabeth M; Baker, Lane A

    2018-06-01

    Solution-phase ion transport during electrospray has been characterized for nanopipettes, or glass capillaries pulled to nanoscale tip dimensions, and micron-sized electrospray ionization emitters. Direct visualization of charged fluorophores during the electrospray process is used to evaluate impacts of emitter size, ionic strength, analyte size, and pressure-driven flow on heterogeneous ion transport during electrospray. Mass spectrometric measurements of positively- and negatively-charged proteins were taken for micron-sized and nanopipette emitters under low ionic strength conditions to further illustrate a discrepancy in solution-driven transport of charged analytes. A fundamental understanding of analyte electromigration during electrospray, which is not always considered, is expected to provide control over selective analyte depletion and enrichment, and can be harnessed for sample cleanup. Graphical abstract Fluorescence micrographs of ion migration in nanoscale pipettes while solution is electrosprayed.

  13. Catalog of Narrow Mg II Absorption Lines in the Baryon Oscillation Spectroscopic Survey

    NASA Astrophysics Data System (ADS)

    Chen, Zhi-Fu; Gu, Qiu-Sheng; Chen, Yan-Mei

    2015-12-01

    Using the Data Release 9 Quasar spectra from the Baryonic Oscillation Spectroscopic Survey, which does not include quasar spectra from the Sloan Digital Sky Survey Data Release 7, we detect narrow Mg ii λλ2796, 2803 absorption doublets in the spectral data redward of 1250 Å (quasar rest frame) until the red wing of the Mg ii λ2800 emission line. Our survey is limited to quasar spectra with a median signal-to-noise ratio < {{S}}/{{N}}> ≥slant 4 pixel-1 in the surveyed spectral region, resulting in a sample that contains 43,260 quasars. We have detected a total of 18,598 Mg ii absorption doublets with 0.2933 ≤ zabs ≤ 2.6529. About 75% of absorbers have an equivalent width at rest frame of {W}rλ 2796≥slant 1 \\mathringA . About 75% of absorbers have doublet ratios ({DR}={W}rλ 2796/{W}rλ 2803) in the range of 1 ≤ DR ≤ 2, and about 3.2% lie outside the range of 1 - σDR ≤ DR ≤ 2 + σDR. We characterize the detection false positives/negatives by the frequency of detected Mg ii absorption doublets in the limits of the S/N of the spectral data. The S/N = 4.5 limit is assigned a completeness fraction of 53% and tends to be complete when the S/N is greater than 4.5. The redshift number densities of all of the detected Mg ii absorbers moderately increase from z ≈ 0.4 to z ≈ 1.5, which parallels the evolution of the cosmic star formation rate density. Limiting our investigation to those quasars whose emission redshift can be determined from narrow emission lines, the relative velocities (β) of Mg ii absorbers have a complex distribution which probably consists of three classes of Mg ii absorbers: (1) cosmologically intervening absorbers; (2) environmental absorbers that reside within the quasar host galaxies or galaxy clusters; (3) quasar outflow absorbers. After subtracting contributions from cosmologically intervening absorbers and environmental absorbers, the β distribution of the Mg iiabsorbers might mainly be contributed by the quasar outflow absorbers and peaks at υ ≈ 1500 km s-1. This peak velocity is lower than the value of 2000 km s-1 found in statistical analysis of C iv absorbers.

  14. Quantification of Protein-Ligand Interactions by Laser Electrospray Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Archer, Jieutonne J.; Karki, Santosh; Shi, Fengjian; Sistani, Habiballah; Levis, Robert J.

    2018-04-01

    Laser electrospray mass spectrometry (LEMS) measurement of the dissociation constant (Kd) for hen egg white lysozyme (HEWL) and N,N',N″-triacetylchitotriose (NAG3) revealed an apparent Kd value of 313.2 ± 25.9 μM for the ligand titration method. Similar measurements for N,N',N″,N″'-tetraacetylchitotetraose (NAG4) revealed an apparent Kd of 249.3 ± 13.6 μM. An electrospray ionization mass spectrometry (ESI-MS) experiment determined a Kd value of 9.8 ± 0.6 μM. In a second LEMS approach, a calibrated measurement was used to determine a Kd value of 6.8 ± 1.5 μM for NAG3. The capture efficiency of LEMS was measured to be 3.6 ± 1.8% and is defined as the fraction of LEMS sample detected after merging with the ESI plume. When the dilution is factored into the ligand titration measurement, the adjusted Kd value was 11.3 μM for NAG3 and 9.0 μM for NAG4. The calibration method for measuring Kd developed in this study can be applied to solutions containing unknown analyte concentrations. [Figure not available: see fulltext.

  15. Trace analysis of trimethoprim and sulfonamide, macrolide, quinolone, and tetracycline antibiotics in chlorinated drinking water using liquid chromatography electrospray tandem mass spectrometry

    USGS Publications Warehouse

    Ye, Z.; Weinberg, H.S.; Meyer, M.T.

    2007-01-01

    A multirun analytical method has been developed and validated for trace determination of 24 antibiotics including 7 sulfonamides, 3 macrolides, 7 quinolones, 6 tetracyclines, and trimethoprim in chlorine-disinfected drinking water using a single solid-phase extraction method coupled to liquid chromatography with positive electrospray tandem mass spectrometry detection. The analytes were extracted by a hydrophilic-lipophilic balanced resin and eluted with acidified methanol (0.1% formic acid), resulting in analyte recoveries generally above 90%. The limits of quantitation were mostly below 10 ng/L in drinking water. Since the concentrated sample matrix typically caused ion suppression during electrospray ionization, the method of standard addition was used for quantitation. Chlorine residuals in drinking water can react with some antibiotics, but ascorbic acid was found to be an effective chlorine quenching agent without affecting the analysis and stability of the antibiotics in water. A preliminary occurrence study using this method revealed the presence of some antibiotics in drinking waters, including sulfamethoxazole (3.0-3.4 ng/L), macrolides (1.4-4.9 ng/L), and quinolones (1.2-4.0 ng/L). ?? 2007 American Chemical Society.

  16. Molecular resolution and fragmentation of fulvic acid by electrospray ionization/multistage tandem mass spectrometry

    USGS Publications Warehouse

    Leenheer, J.A.; Rostad, C.E.; Gates, Paul M.; Furlong, E.T.; Ferrer, I.

    2001-01-01

    Molecular weight distributions of fulvic acid from the Suwannee River, Georgia, were investigated by electrospray ionization/quadrupole mass spectrometry (ESI/QMS), and fragmentation pathways of specific fulvic acid masses were investigated by electrospray ionization/ion trap multistage tandem mass spectrometry (ESI/MST/MS). ESI/QMS studies of the free acid form of low molecular weight poly(carboxylic acid) standards in 75% methanol/25% water mobile phase found that negative ion detection gave the optimum generation of parent ions that can be used for molecular weight determinations. However, experiments with poly(acrylic acid) mixtures and specific high molecular weight standards found multiply charged negative ions that gave a low bias to molecular mass distributions. The number of negative charges on a molecule is dependent on the distance between charges. ESI/MST/MS of model compounds found characteristic water loss from alcohol dehydration and anhydride formation, as well as CO2 loss from decarboxylation, and CO loss from ester structures. Application of these fragmentation pathways to specific masses of fulvic acid isolated and fragmented by ESI/MST/MS is indicative of specific structures that can serve as a basis for future structural confirmation after these hypothesized structures are synthesized.

  17. A Comparison of Tissue Spray and Lipid Extract Direct Injection Electrospray Ionization Mass Spectrometry for the Differentiation of Eutopic and Ectopic Endometrial Tissues

    NASA Astrophysics Data System (ADS)

    Chagovets, Vitaliy; Wang, Zhihao; Kononikhin, Alexey; Starodubtseva, Natalia; Borisova, Anna; Salimova, Dinara; Popov, Igor; Kozachenko, Andrey; Chingin, Konstantin; Chen, Huanwen; Frankevich, Vladimir; Adamyan, Leila; Sukhikh, Gennady

    2018-02-01

    Recent research revealed that tissue spray mass spectrometry enables rapid molecular profiling of biological tissues, which is of great importance for the search of disease biomarkers as well as for online surgery control. However, the payback for the high speed of analysis in tissue spray analysis is the generally lower chemical sensitivity compared with the traditional approach based on the offline chemical extraction and electrospray ionization mass spectrometry detection. In this study, high resolution mass spectrometry analysis of endometrium tissues of different localizations obtained using direct tissue spray mass spectrometry in positive ion mode is compared with the results of electrospray ionization analysis of lipid extracts. Identified features in both cases belong to three lipid classes: phosphatidylcholines, phosphoethanolamines, and sphingomyelins. Lipids coverage is validated by hydrophilic interaction liquid chromatography with mass spectrometry of lipid extracts. Multivariate analysis of data from both methods reveals satisfactory differentiation of eutopic and ectopic endometrium tissues. Overall, our results indicate that the chemical information provided by tissue spray ionization is sufficient to allow differentiation of endometrial tissues by localization with similar reliability but higher speed than in the traditional approach relying on offline extraction.

  18. Simultaneous Determination of Multiple Components in Guanjiekang in Rat Plasma via the UPLC-MS/MS Method and Its Application in Pharmacokinetic Study.

    PubMed

    Wu, Jian; Xie, Ying; Xiang, Zheng; Wang, Canjian; Zhou, Hua; Liu, Liang

    2016-12-16

    Guanjiekang (GJK) that is formed by five medicinal herbs including Astragali Radix , Aconiti Lateralis Radix Praeparaia , Glycyrrhizae Radix et Rhizoma, Corydalis Rhizoma and Paeoniae Radix Alba was used for the treatment of rheumatoid arthritis (RA). However, the pharmacokinetic (PK) profile of active components in GJK remains unclear. This study aims to evaluate the pharmacokinetic behavior of seven representative active constituents in GJK (i.e., benzoylhypaconine, benzoylmesaconine, paeoniflorin, tetrahydropalmatine, calycosin-7-glucoside, formononetin and isoliquiritigenin) after oral administration of GJK in rats. A rapid, sensitive and reliable ultra-performance liquid chromatography-tandem mass spectrometer (UPLC-MS/MS) method has been successfully developed for the simultaneous determination of these seven constituents in rat plasma. Chromatographic separation was achieved on a C 18 column with a gradient elution program that consists of acetonitrile and water (containing 0.1% formic acid) at a flow rate of 0.35 mL/min. Detection was performed under the multiple reaction monitoring (MRM) in the positive electrospray ionization (ESI) mode. The calibration curves exhibited good linearity (R² > 0.99) over a wide concentration range for all constituents. The accuracies ranged from 92.9% to 107.8%, and the intra-day and inter-day precisions at three different levels were below 15%. Our PK results showed that these seven compounds were quickly absorbed after the administration of the GJK product, and T max ranged from 30 min to 189 min. The in vivo concentrations of paeoniflorin and isoliquiritigenin were significantly higher than the reported in vitro effective doses, indicating that they could partly contribute to the therapeutic effect of GJK. Therefore, we conclude that pharmacokinetic studies of representative bioactive chemicals after administration of complex herbal products are not only necessary but also feasible. Moreover, these seven compounds that were absorbed in vivo can be used as indicator standards for quality control and for determining pharmacokinetic behavior of herbal medicines in clinical studies.

  19. The great importance of normalization of LC-MS data for highly-accurate non-targeted metabolomics.

    PubMed

    Mizuno, Hajime; Ueda, Kazuki; Kobayashi, Yuta; Tsuyama, Naohiro; Todoroki, Kenichiro; Min, Jun Zhe; Toyo'oka, Toshimasa

    2017-01-01

    The non-targeted metabolomics analysis of biological samples is very important to understand biological functions and diseases. LC combined with electrospray ionization-based MS has been a powerful tool and widely used for metabolomic analyses. However, the ionization efficiency of electrospray ionization fluctuates for various unexpected reasons such as matrix effects and intraday variations of the instrument performances. To remove these fluctuations, normalization methods have been developed. Such techniques include increasing the sensitivity, separating co-eluting components and normalizing the ionization efficiencies. Normalization techniques allow simultaneously correcting of the ionization efficiencies of the detected metabolite peaks and achieving quantitative non-targeted metabolomics. In this review paper, we focused on these normalization methods for non-targeted metabolomics by LC-MS. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Combined electrophoretic-separation and electrospray method and system

    DOEpatents

    Smith, Richard D.; Olivares, Jose A.

    1989-01-01

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary zone electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit.

  1. A modified Girard derivatizing reagent for universal profiling and trace analysis of aldehydes and ketones by electrospray ionization tandem mass spectrometry.

    PubMed

    Johnson, David W

    2007-01-01

    4-Hydrazino-N,N,N-trimethyl-4-oxobutanaminium iodide (HTMOB) is a modified Girard derivatizing reagent synthesized to improve the sensitivity of analysis of aldehydes and ketones with electrospray ionization tandem mass spectrometry. Compared with Girard T reagent the measured signal intensity increase is between 3.3 times (succinylacetone) and 7.0 times (17-hydroxyprogesterone). HTMOB is a universal profiling reagent for aldehydes and ketones. A neutral loss of 59 Da scan detects all aldehydes and ketones from acetone to corticosteroids. Applications described include the profiling of ketones, ketoacids and ketodiacids in the urine of children with ketosis and the profiling of long-chain aldehydes incorporated in plasma plasmalogens. Copyright (c) 2007 John Wiley & Sons, Ltd.

  2. A novel route to recognizing quaternary ammonium cations using electrospray mass spectrometry.

    PubMed

    Shackman, Holly M; Ding, Wei; Bolgar, Mark S

    2015-01-01

    Characterizing and elucidating structures is a commonplace and necessary activity in the pharmaceutical industry with mass spectrometry and NMR being the primary tools for analysis. Although many functional groups are readily identifiable, quaternary ammonium cations have proven to be difficult to unequivocally identify using these techniques. Due to the lack of an N-H bond, quaternary ammonium groups can only be detected in the (1)H NMR spectra by weak signals generated from long-range (14)N-H coupling, which by themselves are inconclusive evidence of a quaternary ammonium functional group. Due to their low intensity, these signals are frequently not detected. Additionally, ions cannot be differentiated in a mass spectrum as an M(+) or [M + H](+) ion without prior knowledge of the compound's structure. In order to utilize mass spectrometry as a tool for determining this functionality, ion cluster formation of quaternary ammonium cations and non-quaternary amines was studied using electrospray ionization. Several mobile phase modifiers were compared; however, the addition of small amounts of trifluoroacetic acid proved superior in producing characteristic and intense [M +2TFA](-) clusters for compounds containing quaternary ammonium cations when using negative electrospray. By fragmenting this characteristic ion using CID, nearly all compounds studied could be unambiguously identified as containing a quaternary ammonium cation or a non-quaternary amine attributable to the presence (non-quaternary amine) or absence (quaternary ammonium cation) of the resulting [2TFA + H](-) ion in the product spectra. This method of analysis provides a rapid, novel, and reliable technique for indicating the presence of quaternary ammonium cations in order to aid in structural elucidation.

  3. A Fluidically Tunable Metasurface Absorber for Flexible Large-Scale Wireless Ethanol Sensor Applications.

    PubMed

    Kim, Hyung Ki; Lee, Dongju; Lim, Sungjoon

    2016-08-06

    In this paper, a novel flexible tunable metasurface absorber is proposed for large-scale remote ethanol sensor applications. The proposed metasurface absorber consists of periodic split-ring-cross resonators (SRCRs) and microfluidic channels. The SRCR patterns are inkjet-printed on paper using silver nanoparticle inks. The microfluidic channels are laser-etched on polydimethylsiloxane (PDMS) material. The proposed absorber can detect changes in the effective permittivity for different liquids. Therefore, the absorber can be used for a remote chemical sensor by detecting changes in the resonant frequencies. The performance of the proposed absorber is demonstrated with full-wave simulation and measurement results. The experimental results show the resonant frequency increases from 8.9 GHz to 10.04 GHz when the concentration of ethanol is changed from 0% to 100%. In addition, the proposed absorber shows linear frequency shift from 20% to 80% of the different concentrations of ethanol.

  4. Detection of Metastatic Breast and Thyroid Cancer in Lymph Nodes by Desorption Electrospray Ionization Mass Spectrometry Imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Jialing; Feider, Clara L.; Nagi, Chandandeep; Yu, Wendong; Carter, Stacey A.; Suliburk, James; Cao, Hop S. Tran; Eberlin, Livia S.

    2017-06-01

    Ambient ionization mass spectrometry has been widely applied to image lipids and metabolites in primary cancer tissues with the purpose of detecting and understanding metabolic changes associated with cancer development and progression. Here, we report the use of desorption electrospray ionization mass spectrometry (DESI-MS) to image metastatic breast and thyroid cancer in human lymph node tissues. Our results show clear alterations in lipid and metabolite distributions detected in the mass spectra profiles from 42 samples of metastatic thyroid tumors, metastatic breast tumors, and normal lymph node tissues. 2D DESI-MS ion images of selected molecular species allowed discrimination and visualization of specific histologic features within tissue sections, including regions of metastatic cancer, adjacent normal lymph node, and fibrosis or adipose tissues, which strongly correlated with pathologic findings. In thyroid cancer metastasis, increased relative abundances of ceramides and glycerophosphoinisitols were observed. In breast cancer metastasis, increased relative abundances of various fatty acids and specific glycerophospholipids were seen. Trends in the alterations in fatty acyl chain composition of lipid species were also observed through detailed mass spectra evaluation and chemical identification of molecular species. The results obtained demonstrate DESI-MSI as a potential clinical tool for the detection of breast and thyroid cancer metastasis in lymph nodes, although further validation is needed. [Figure not available: see fulltext.

  5. METHODS DEVELOPMENT TO IMPROVE LOW-LEVEL PERCHLORATE DETECTION IN DRINKING WATER BY CONDUCTIVITY AND MASS SPECTROMETRY - ISSUES AND IMPACT

    EPA Science Inventory

    The goal of this research is to develop a USEPA method for the determination of sub-ppb concentrations of the perchlorate anion in ground and surface drinking waters. To date, ion chromatography using a KOH mobile phase, electrolytic conductivity suppression and electrospray ion...

  6. Fragmentation study of iridoid glycosides including epimers by liquid chromatography-diode array detection/electrospray ionization mass spectrometry and its application in metabolic fingerprint analysis of Gardenia jasminoides Ellis.

    PubMed

    Zhou, Tingting; Liu, Hua; Wen, Jun; Fan, Guorong; Chai, Yifeng; Wu, Yutian

    2010-09-15

    A high-performance liquid chromatography-diode array detection/electrospray ionization mass spectrometry (HPLC-DAD/ESI-MS) method was applied to the characterization of ten iridoid glycosides in Gardenia jasminoides Ellis, a traditional Chinese medicine. During the process of structural elucidation, two groups of isomers including two epimers were structurally characterized and differentiated according to their distinctive fragmentation patterns which were closely related to their isomeric differentiations. Subsequently, the major compounds were purified by multi-dimensional chromatography and semi-preparative HPLC and the structure identification was confirmed with NMR techniques. The major fragmentation pathways of iridoid glycosides in Gardenia jasminoides Ellis obtained through the MS data were schemed systematically, which provided the best sensitivity and specificity for characterization of the iridoid glycosides especially the isomers so far. Based on the fragmentation patterns of iridoid glycosides concluded, seven major iridoid glycosides were characterized in rat plasma after intravenous administration of Gardenia jasminoides Ellis. Copyright 2010 John Wiley & Sons, Ltd.

  7. Characterization of the components of meleumycin by liquid chromatography with photo-diode array detection and electrospray ionization tandem mass spectrometry.

    PubMed

    Wang, Ming-Juan; Li, Ya-Ping; Wang, Yan; Li, Jin; Hu, Chang-Qin; Hoogmartens, Jos; Van Schepdael, Ann; Adams, Erwin

    2013-10-01

    Reversed-phase liquid chromatography coupled with photo-diode array (PDA) detection and electrospray ionization tandem mass spectrometry (ESI-MS/MS) was used to characterize the components of meleumycin, a 16-membered macrolide antibiotic produced by fermentation. In total 31 components were characterized in commercial samples, including 12 impurities that had never been reported before and 12 others that were partially characterized. The structures of these unknown compounds were deduced by comparison of their fragmentation patterns with those of known components. Their ultraviolet spectra and chromatographic behavior were used to confirm the proposed structures: e.g. λmax shift from 232 nm to 282 nm would indicate the presence of an α-, β-, γ-, δ-unsaturated ketone instead of a normal α-, β-, γ-, δ-unsaturated alcohol in the 16-membered ring of the examined components. Compared to other methods, this LC/MS(n) method is particularly advantageous to characterize minor components at trace levels in multi-components antibiotics, in terms of sensitivity and efficiency. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Direct analysis of psychoactive tryptamine and harmala alkaloids in the Amazonian botanical medicine ayahuasca by liquid chromatography-electrospray ionization-tandem mass spectrometry.

    PubMed

    McIlhenny, Ethan H; Pipkin, Kelly E; Standish, Leanna J; Wechkin, Hope A; Strassman, Rick; Barker, Steven A

    2009-12-18

    A direct injection/liquid chromatography-electrospray ionization-tandem mass spectrometry procedure has been developed for the simultaneous quantitation of 11 compounds potentially found in the increasingly popular Amazonian botanical medicine and religious sacrament ayahuasca. The method utilizes a deuterated internal standard for quantitation and affords rapid detection of the alkaloids by a simple dilution assay, requiring no extraction procedures. Further, the method demonstrates a high degree of specificity for the compounds in question, as well as low limits of detection and quantitation despite using samples for analysis that had been diluted up to 200:1. This approach also appears to eliminate potential matrix effects. Method bias for each compound, examined over a range of concentrations, was also determined as was inter- and intra-assay variation. Its application to the analysis of three different ayahuasca preparations is also described. This method should prove useful in the study of ayahuasca in clinical and ethnobotanical research as well as in forensic examinations of ayahuasca preparations.

  9. A multifunctional fluorescence sensor for Cd2+, PO43- and Cr3+ in different system and the practical application.

    PubMed

    Wang, Qingming; Tan, Yingzi; Wang, Nianhua; Lu, Zhixiang; Wang, Wenling

    2018-05-07

    A fluorescence probe based on thiosemicarbazide has been synthesized and well characterized by 1 H NMR, 13 C NMR, Elemental analysis, Electrospray ionization mass spectra. The probe 1 functions as a multitarget ion sensor, detect biologically and ecologically important Cd 2+ , PO 4 3- and Cr 3+ . Meanwhile, probe 1 displays selectivity for Cd 2+ over other metal ions and anions in DMF by emission spectrum. Interestingly, probe 1 has been explored to recognize PO 4 3- in CH 3 OH-H 2 O (v:v = 1:9). The binding stoichiometry of probe 1 with Cd 2+ and PO 4 3- are 2:1 and 1:1, respectively, which are confirmed by Electrospray ionization mass spectra. Probe 1 is selective, sensitive and reversibility/reusability to Cd 2+ and PO 4 3- with the detection limit as low as 0.035 μM and 0.011 μM respectively. Besides, the designed probe 1 has shown potential applications in the area of photo-printing. Copyright © 2018. Published by Elsevier B.V.

  10. Imaging Nicotine in Rat Brain Tissue by Use of Nanospray Desorption Electrospray Ionization Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lanekoff, Ingela T.; Thomas, Mathew; Carson, James P.

    Imaging mass spectrometry offers simultaneous detection of drugs, drug metabolites and endogenous substances in a single experiment. This is important when evaluating effects of a drug on a complex organ system such as the brain, where there is a need to understand how regional drug distribution impacts function. Nicotine is an addictive drug and its action in the brain is of high interest. Here we use nanospray desorption electrospray ionization, nano-DESI, imaging to discover the localization of nicotine in rat brain tissue after in vivo administration of nicotine. Nano-DESI is a new ambient technique that enables spatially-resolved analysis of tissuemore » samples without special sample pretreatment. We demonstrate high sensitivity of nano-DESI imaging that enables detection of only 0.7 fmole nicotine per pixel in the complex brain matrix. Furthermore, by adding deuterated nicotine to the solvent, we examined how matrix effects, ion suppression, and normalization affect the observed nicotine distribution. Finally, we provide preliminary results suggesting that nicotine localizes to the hippocampal substructure called dentate gyrus.« less

  11. Desorption electrospray ionization (DESI) with atmospheric pressure ion mobility spectrometry for drug detection.

    PubMed

    Roscioli, Kristyn M; Tufariello, Jessica A; Zhang, Xing; Li, Shelly X; Goetz, Gilles H; Cheng, Guilong; Siems, William F; Hill, Herbert H

    2014-04-07

    Desorption electrospray ionization (DESI) was coupled to an ambient pressure drift tube ion mobility time-of-flight mass spectrometer (IM-TOFMS) for the direct analysis of active ingredients in pharmaceutical samples. The DESI source was also coupled with a standalone IMS demonstrating potential of portable and inexpensive drug-quality testing platforms. The DESI-IMS required no sample pretreatment as ions were generated directly from tablets and cream formulations. The analysis of a range of over-the-counter and prescription tablet formations was demonstrated for amphetamine (methylphenidate), antidepressant (venlafaxine), barbiturate (Barbituric acid), depressant (alprazolam), narcotic (3-methylmorphine) and sympatholytic (propranolol) drugs. Active ingredients from soft and liquid formulations, such as Icy Hot cream (methyl salicylate) and Nyquil cold medicine (acetaminophen, dextromethorphan, doxylamine) were also detected. Increased sensitivity for selective drug responses was demonstrated through the formation of sodiated adduct ions by introducing small quantities of NaCl into the DESI solvent. Of the drugs and pharmaceuticals tested in this study, 68% (22 total samples) provided a clear ion mobility response at characteristic mobilities either as (M + H)(+), (M - H)(-), or (M + Na)(+) ions.

  12. Determination of fluspirilene in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionisation.

    PubMed

    Swart, K J; Sutherland, F C; van Essen, G H; Hundt, H K; Hundt, A F

    1998-12-18

    An ultra-sensitive method for the determination of fluspirilene in plasma was established, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. The samples were extracted with hexane/isoamyl alcohol, separated on a Phenomenex Luna C18 5 mu 150 x 2.1 mm column with a mobile phase consisting of methanol-water-acetic acid (600:400:1) at a flow-rate of 0.3 ml/min. Detection was achieved by a Finnigan Matt mass spectrometer (LCQ) at unit resolution in full scan mode scanning the product ion spectrum from m/z 130-500 and monitoring the transition of the protonated molecular ion at m/z 476.2, to the sum of the largest product ions m/z 371, 342 and 274 (MS-MS). Electrospray ionisation was used for ion production. The mean recovery for fluspirilene was 90% with a lower limit of quantification of 21.50 pg/ml using 1 ml plasma for extraction. This is the first chromatographic method described for the determination of fluspirilene in plasma that is accurate and sensitive enough to be used in pharmacokinetic studies.

  13. Liquid chromatography-electrospray ionization tandem mass spectrometry and dynamic multiple reaction monitoring method for determining multiple pesticide residues in tomato.

    PubMed

    Andrade, G C R M; Monteiro, S H; Francisco, J G; Figueiredo, L A; Botelho, R G; Tornisielo, V L

    2015-05-15

    A quick and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method, using dynamic multiple reaction monitoring and a 1.8-μm particle size analytical column, was developed to determine 57 pesticides in tomato in a 13-min run. QuEChERS (quick, easy, cheap, effective, rugged, and safe) method for samples preparations and validations was carried out in compliance with EU SANCO guidelines. The method was applied to 58 tomato samples. More than 84% of the compounds investigated showed limits of detection equal to or lower than 5 mg kg(-1). A mild (<20%), medium (20-50%), and strong (>50%) matrix effect was observed for 72%, 25%, and 3% of the pesticides studied, respectively. Eighty-one percent of the pesticides showed recoveries ranging between 70% and 120%. Twelve pesticides were detected in 35 samples, all below the maximum residue levels permitted in the Brazilian legislation; 15 samples exceeded the maximum residue levels established by the EU legislation for methamidophos; and 10 exceeded limits for acephate and four for bromuconazole. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Determination of abamectin, doramectin, emamectin, eprinomectin, ivermectin, and moxidectin in milk by liquid chromatography electrospray tandem mass specrometry.

    PubMed

    Sheridan, Robert; Desjardins, Lucille

    2006-01-01

    The avermectin and milbemycin families of compounds are derived from naturally occurring yeasts. They have proven to be potent preventatives against a variety of pests such as insects and parasites. Only eprinomectin and moxidectin are currently approved for use on lactating cattle with tolerances in milk of 12 microg/kg for eprinomectin and 40 microg/kg for moxidectin. Detection of misuse or inadvertent contamination in milk requires a sensitive and definitive analytical method. A method has been developed for the determination of 5 avermectins and 1 milbemycin in milk using a simple liquid-liquid extraction and liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis. Ivermectin (IVR), doramectin (DOR), abamectin (ABA), eprinomectin (EPR), emamectin (EMA), and moxidectin (MOX) were extracted from whole milk by partitioning into acetonitrile with a subsequent solvent exchange into methanol-water. Simultaneous confirmation and quantification were achieved with LC separation, positive electrospray ionization (ESI+), and MS/MS. The limits of detection ranged from 16 pg/g (ppt) for EMA to 1.7 microg/g (ppb) for MOX.

  15. Detection of transient radical cations in electron transfer-initiated Diels-Alder reactions by electrospray ionization mass spectrometry.

    PubMed

    Fürmeier, Sven; Metzger, Jürgen O

    2004-11-10

    The coupling of a simple microreactor to an atmospheric pressure ion source, such as electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI), allows the investigation of reactions in solution by mass spectrometry. The tris(p-bromophenyl)aminium hexachloroantimonate (1(*)(+)SbCl(6)(-))-initiated reactions of phenylvinylsulfide (2) and cyclopentadiene (3) and of trans-anethole (5) and isoprene (6) and the dimerization of 1,3-cyclohexadiene (8) to give the respective Diels-Alder products were studied. These preparatively interesting reactions proceed as radical cation chain reactions via the transient radical cations of the respective dienophiles and of the respective Diels-Alder addition products. These radical cations could be detected directly and characterized unambiguously in the reacting solution by ESI-MS-MS. The identity was confirmed by comparison with MS-MS spectra of the authentic radical cations obtained by APCI-MS and by CID experiments of the corresponding molecular ions generated by EI-MS. In addition, substrates and products could be monitored easily in the reacting solution by APCI-MS.

  16. A new method for differentiating adducts of common drinking water DBPs from higher molecular weight DBPs in electrospray ionization-mass spectrometry analysis.

    PubMed

    Zhai, Hongyan; Zhang, Xiangru

    2009-05-01

    With the presence of bromide in source waters, numerous brominated disinfection byproducts (DBPs) are formed during chlorination. Many of them are polar/highly polar DBPs and thus hard to be detected by gas chromatography mass spectrometry. Electrospray ionization triple quadrupole mass spectrometry (ESI-MS/MS) is reported to be an effective method in finding polar brominated DBPs by setting precursor ion scans of m/z 79 and 81. But as a soft ionization technique, ESI could form adducts of common DBPs, which may complicate ESI-MS/MS spectra and hinder the efforts in finding new brominated DBPs. In this paper, a new method was developed for differentiating adducts of common DBPs from higher molecular weight DBPs. This method was based on the ESI-MS/MS precursor ion scans of the fragments that correspond to the molecular ions of common DBPs. Adducts of common DBPs were selectively detected in the ESI-MS/MS spectra of a simulated drinking water sample. Moreover, the structures of several new brominated DBPs in the sample were tentatively proposed.

  17. Remote mass spectrometric sampling of electrospray- and desorption electrospray-generated ions using an air ejector.

    PubMed

    Dixon, R Brent; Bereman, Michael S; Muddiman, David C; Hawkridge, Adam M

    2007-10-01

    A commercial air ejector was coupled to an electrospray ionization linear ion trap mass spectrometer (LTQ) to transport remotely generated ions from both electrospray (ESI) and desorption electrospray ionization (DESI) sources. We demonstrate the remote analysis of a series of analyte ions that range from small molecules and polymers to polypeptides using the AE-LTQ interface. The details of the ESI-AE-LTQ and DESI-AE-LTQ experimental configurations are described and preliminary mass spectrometric data are presented.

  18. Remote Mass Spectrometric Sampling of Electrospray- and Desorption Electrospray-Generated Ions Using an Air Ejector

    PubMed Central

    Dixon, R. Brent; Bereman, Michael S.; Muddiman, David C.; Hawkridge, Adam M.

    2007-01-01

    A commercial air ejector was coupled to an electrospray ionization linear ion trap mass spectrometer (LTQ) to transport remotely generated ions from both electrospray (ESI) and desorption electrospray ionization (DESI) sources. We demonstrate the remote analysis of a series of analyte ions that range from small molecules and polymers to polypeptides using the AE-LTQ interface. The details of the ESI-AE-LTQ and DESI-AE-LTQ experimental configurations are described and preliminary mass spectrometric data is presented. PMID:17716909

  19. Low pressure electrospray ionization system and process for effective transmission of ions

    DOEpatents

    Tang, Keqi [Richland, WA; Page, Jason S [Kennewick, WA; Kelly, Ryan T [West Richland, WA; Smith, Richard D [Richland, WA

    2012-05-08

    Systems and methods that provide up to complete transmission of ions between coupled stages with low effective ion losses. An "interfaceless" electrospray ionization system is further described that operates an electrospray at a reduced pressure such that standard electrospray sample solutions can be directly sprayed into an electrodynamic ion funnel which provides ion focusing and transmission of ions into a mass analyzer. Furthermore, chambers maintained at different pressures can allow for more optimal operating conditions for an electrospray emitter and an ion guide.

  20. Direct Analysis of Proteins from Solutions with High Salt Concentration Using Laser Electrospray Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Karki, Santosh; Shi, Fengjian; Archer, Jieutonne J.; Sistani, Habiballah; Levis, Robert J.

    2018-05-01

    The detection of lysozyme, or a mixture of lysozyme, cytochrome c, and myoglobin, from solutions with varying salt concentrations (0.1 to 250 mM NaCl) is compared using laser electrospray mass spectrometry (LEMS) and electrospray ionization-mass spectrometry (ESI-MS). Protonated protein peaks were observed up to a concentration of 250 mM NaCl in the case of LEMS. In the case of ESI-MS, a protein solution with salt concentration > 0.5 mM resulted in predominantly salt-adducted features, with suppression of the protonated protein ions. The constituents in the mixture of proteins were assignable up to 250 mM NaCl for LEMS and were not assignable above a NaCl concentration of 0.5 mM for ESI. The average sodium adducts (< n >) bound to the 7+ charge state of lysozyme for LEMS measurements from salt concentrations of 2.5, 25, 50, and 100 mM NaCl are 1.71, 5.23, 5.26, and 5.11, respectively. The conventional electrospray measurements for lysozyme solution containing salt concentrations of 0.1, 1, 2, and 5 mM NaCl resulted in < n > of 2.65, 6.44, 7.57, and 8.48, respectively. LEMS displays an approximately two orders of magnitude higher salt tolerance in comparison with conventional ESI-MS. The non-equilibrium partitioning of proteins on the surface of the charged droplets is proposed as the mechanism for the high salt tolerance phenomena observed in the LEMS measurements. [Figure not available: see fulltext.

  1. Direct Analysis of Proteins from Solutions with High Salt Concentration Using Laser Electrospray Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Karki, Santosh; Shi, Fengjian; Archer, Jieutonne J.; Sistani, Habiballah; Levis, Robert J.

    2018-03-01

    The detection of lysozyme, or a mixture of lysozyme, cytochrome c, and myoglobin, from solutions with varying salt concentrations (0.1 to 250 mM NaCl) is compared using laser electrospray mass spectrometry (LEMS) and electrospray ionization-mass spectrometry (ESI-MS). Protonated protein peaks were observed up to a concentration of 250 mM NaCl in the case of LEMS. In the case of ESI-MS, a protein solution with salt concentration > 0.5 mM resulted in predominantly salt-adducted features, with suppression of the protonated protein ions. The constituents in the mixture of proteins were assignable up to 250 mM NaCl for LEMS and were not assignable above a NaCl concentration of 0.5 mM for ESI. The average sodium adducts (< n >) bound to the 7+ charge state of lysozyme for LEMS measurements from salt concentrations of 2.5, 25, 50, and 100 mM NaCl are 1.71, 5.23, 5.26, and 5.11, respectively. The conventional electrospray measurements for lysozyme solution containing salt concentrations of 0.1, 1, 2, and 5 mM NaCl resulted in < n > of 2.65, 6.44, 7.57, and 8.48, respectively. LEMS displays an approximately two orders of magnitude higher salt tolerance in comparison with conventional ESI-MS. The non-equilibrium partitioning of proteins on the surface of the charged droplets is proposed as the mechanism for the high salt tolerance phenomena observed in the LEMS measurements. [Figure not available: see fulltext.

  2. Ions generated from uranyl nitrate solutions by electrospray ionization (ESI) and detected with Fourier transform ion-cyclotron resonance (FT-ICR) mass spectrometry.

    PubMed

    Pasilis, Sofie; Somogyi, Arpád; Herrmann, Kristin; Pemberton, Jeanne E

    2006-02-01

    Electrospray ionization (ESI) of uranyl nitrate solutions generates a wide variety of positively and negatively charged ions, including complex adducts of uranyl ions with methoxy, hydroxy, and nitrate ligands. In the positive ion mode, ions detected by Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry are sensitive to instrumental tuning parameters such as quadrupole operating frequency and trapping time. Positive ions correspond to oligomeric uranyl nitrate species that can be characterized as having a general formula of [(UO(2))(n)(A)(m)(CH(3)OH)(s)](+) or [(UO(2))(n)(O)(A)(m)(CH(3)OH)(s)](+) with n = 1-4, m = 1-7, s = 0 or 1, and A = OH, NO(3), CH(3)O or a combination of these, although the formation of NO(3)-containing species is preferred. In the negative ion mode, complexes of the form [(UO(2))(NO(3))(m)](-) (m = 1-3) are detected, although the formation of the oxo-containing ions [(UO(2))(O)(n)(NO(3))(m)](-) (n = 1-2, m = 1-2) and the hydroxy-containing ions [(UO(2))(OH)(n)(NO(3))(m)](-) (n = 1-2, m = 0-1) are also observed. The extent of coordinative unsaturation of both positive and negative ions can be determined by ligand association/exchange and H/D exchange experiments using D(2)O and CD(3)OD as neutral reaction partners in the gas-phase. Positive ions are of varying stability and reactivity and may fragment extensively upon collision with D(2)O, CD(3)OD and N(2) in sustained off-resonance irradiation/collision-induced dissociation (SORI-CID) experiments. Electron-transfer reactions, presumably occurring during electrospray ionization but also in SORI-CID, can result in reduction of U(VI) to U(V) and perhaps even U(IV).

  3. Hydrogen sulfide measurement using sulfide dibimane: critical evaluation with electrospray ion trap mass spectrometry

    PubMed Central

    Shen, Xinggui; Chakraborty, Sourav; Dugas, Tammy R; Kevil, Christopher G

    2015-01-01

    Accurate measurement of hydrogen sulfide bioavailability remains a technical challenge due to numerous issues involving sample processing, detection methods used, and actual biochemical products measured. Our group and others have reported that reverse phase HPLC detection of sulfide dibimane (SDB) product from the reaction of H2S/HS− with monobromobimane allows for analytical detection of hydrogen sulfide bioavailability in free and other biochemical forms. However, it remains unclear whether possible interfering contaminants may contribute to HPLC SDB peak readings that may result in inaccurate measurements of bioavailable sulfide. In this study, we critically compared hydrogen sulfide dependent SDB detection using reverse phase HPLC (RP-HPLC) versus quantitative SRM electrospray ionization mass spectrometry (ESI/MS) to obtain greater clarity into the validity of the reverse phase HPLC method for analytical measurement of hydrogen sulfide. Using an LCQ-deca ion-trap mass spectrometer, SDB was identified by ESI/MS positive ion mode, and quantified by selected reaction monitoring (SRM) using hydrocortisone as an internal standard. Collision induced dissociation (CID) parameters were optimized at MS2 level for SDB and hydrocortisone. ESI/MS detection of SDB standard was found to be a log order more sensitive than RP-HPLC with a lower limit of 0.25 nM. Direct comparison of tissue and plasma SDB levels using RP-HPLC and ESI/MS methods revealed comparable sulfide levels in plasma, aorta, heart, lung and brain. Together, these data confirm the use of SDB as valid indicator of H2S bioavailability and highlights differences between analytical detection methods. PMID:24932544

  4. Saturated fatty acid determination method using paired ion electrospray ionization mass spectrometry coupled with capillary electrophoresis.

    PubMed

    Lee, Ji-Hyun; Kim, Su-Jin; Lee, Sul; Rhee, Jin-Kyu; Lee, Soo Young; Na, Yun-Cheol

    2017-09-01

    A sensitive and selective capillary electrophoresis-mass spectrometry (CE-MS) method for determination of saturated fatty acids (FAs) was developed by using dicationic ion-pairing reagents forming singly charged complexes with anionic FAs. For negative ESI detection, 21 anionic FAs at pH 10 were separated using ammonium formate buffer containing 40% acetonitrile modifier in normal polarity mode in CE by optimizing various parameters. This method showed good separation efficiency, but the sensitivity of the method to short-chain fatty acids was quite low, causing acetic and propionic acids to be undetectable even at 100 mgL -1 in negative ESI-MS detection. Out of the four dicationic ion-pairing reagents tested, N,N'-dibutyl 1,1'-pentylenedipyrrolidium infused through a sheath-liquid ion source during CE separation was the best reagent regarding improved sensitivity and favorably complexed with anionic FAs for detection in positive ion ESI-MS. The monovalent complex showed improved ionization efficiency, providing the limits of detection (LODs) for 15 FAs ranging from 0.13 to 2.88 μg/mL and good linearity (R 2  > 0.99) up to 150 μg/mL. Compared to the negative detection results, the effect was remarkable for the detection of short- and medium-chain fatty acids. The optimized CE-paired ion electrospray (PIESI)-MS method was utilized for the determination of FAs in cheese and coffee with simple pretreatment. This method may be extended for sensitive analysis of unsaturated fatty acids. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Electrospray Charging of Minerals: Surface Chemistry and Applications to High-Velocity Microparticle Impacts

    NASA Astrophysics Data System (ADS)

    Daly, T.; Call, S.; Austin, D. E.

    2010-12-01

    Electrospray is a soft ionization technique commonly used to charge large biomolecules; it has, however, also been applied to inorganic compounds. We are extending this technique to mineral microparticles. Electrospray-charged mineral microparticles are interesting in the context of surface science because surface chemistry dictates where and how charge carriers can bond to mineral surfaces. In addition, using electrospray to charge mineral particles allows these particles to be electrostatically accelerated as projectiles in high- and hyper-velocity impacts. Since current techniques for producing high- and hyper-velocity microparticle impacts are largely limited to metal or metal-coated projectiles, using minerals as projectiles is a significant innovation. Electrospray involves three steps: creation of charged droplets containing solute/particles, evaporation and bifurcation of droplets, and desolvation of the solute/particles. An acidified solution is slowly pumped through a needle in a strong DC field, which causes the solution to break into tiny, charged droplets laden with protons. Solvent evaporates from the electrosprayed droplets as they move through the electric field toward a grounded plate, causing the charge on the droplet to increase relative to its mass. When the electrosprayed droplet’s charge becomes such that the droplet is no longer stable, it bifurcates, and each of the resulting droplets carries some of the original droplet’s charge. Evaporation and bifurcation continues until the solute particle is completely desolvated. The result is a protonated solute molecule or particle. We built an instrument that electrosprays particles into vacuum and measures them using an image charge detector. Mineral microparticles were prepared by grinding natural mineral samples to ~2 µm diameter. These microparticles are then added to a 4:1 methanol:water solution to create a 0.005% w/v suspension. The suspension is electrosprayed into vacuum, where the charge detector measures the electrosprayed mineral particles’ speed and charge. Quartz microparticles have been successfully electrosprayed. Variation in quartz microparticles’ charge as a function of pH is being evaluated. In addition, we are studying how to completely desolvate electrosprayed mineral particles. Desolvation is not trivial and often requires more than the passive passage of the droplets from the needle to the grounded plate and into vacuum. We are testing two desolvation methods: a heated beam tube and a heated capillary. Preliminary data suggests we have achieved complete desolvation with a hot beam tube. Although quartz’s surface chemistry is rather unique, successful electrospray of quartz microparticles strongly suggests that other minerals may also be electrosprayed. We are preparing olivine samples for electrospray. In addition, an instrument that creates high-velocity microparticle impacts using electrospray-charged mineral microparticles is being developed. This instrument will not only permit minerals to be used as projectiles, but also allows direction characterization of chemical speciation occurring during microparticle impacts.

  6. Polar organic chemical integrative sampling and liquid chromatography- electrospray/ion-trap mass spectrometry for assessing selected prescription and illicit drugs in treated sewage effluents

    USGS Publications Warehouse

    Jones-Lepp, T. L.; Alvarez, D.A.; Petty, J.D.; Huckins, J.N.

    2004-01-01

    The purpose of the research presented in this paper was twofold: (1) to demonstrate the coupling of two state-of-the-art techniques: a time-weighted polar organic chemical integrative sampler (POCIS) and microliquid chromatography–electrospray/ion-trap mass spectrometry and (2) to assess the ability of these methodologies to detect six drugs (azithromycin, fluoxetine, omeprazole, levothyroxine, methamphetamine, methylenedioxymethamphetamine [MDMA]) in a real-world environment, e.g., waste water effluent. In the effluent from three wastewater treatment plants (WWTPs), azithromycin was detected at concentrations ranging from 15 to 66 ng/L, which is equivalent to a total annual release of 1 to 4 kg into receiving waters. Detected and confirmed in the effluent from two WWTPs were two illicit drugs, methamphetamine and MDMA, at 2 and 0.5 ng/L, respectively. Although the ecotoxicologic significance of drugs in environmental matrices, particularly water, has not been closely examined, it can only be surmised that these substances have the potential to adversely affect biota that are continuously exposed to them even at very low levels. The potential for chronic effects on human health is also unknown but of increasing concern because of the multiuse character of water, particularly in densely populated, arid areas.

  7. Quantitative analysis of the eight major compounds in the Samsoeum using a high-performance liquid chromatography coupled with diode array detection and electrospray ionization mass spectrometer

    PubMed Central

    Weon, Jin Bae; Yang, Hye Jin; Lee, Bohyoung; Ma, Jin Yeul; Ma, Choong Je

    2015-01-01

    Background: Samsoeum was traditionally used for treatment of a respiratory disease. Objective: The simultaneous determination of eight major compounds, ginsenoside Rg3, caffeic acid, puerarin, costunolide, hesperidin, naringin, glycyrrhizin, and 6-gingerol in the Samsoeum using a high-performance liquid chromatography (HPLC) coupled with diode array detection (DAD) and an electrospray ionization mass spectrometer was developed for an accurate and reliable quality assessment. Materials and Methods: Eight compounds were qualitative identified based on their mass spectra and by comparing with standard compounds and quantitative analyzed by HPLC-DAD. Separation of eight compounds was carried out on a LUNA C18 column (S-5 μm, 4.6 mm i.d. ×250 mm) with gradient elution composed of acetonitrile and 0.1% trifluoroacetic acid. Results: The data showed good linearity (R2 > 0.9996). The limits of detection and the limits of quantification were <0.53 μg and 1.62 μg, respectively. Inter- and Intra-day precisions (expressed as relative standard deviation values) were within 1.94% and 1.91%, respectively. The recovery of the method was in the range of 94.24–107.90%. Conclusion: The established method is effective and could be applied to quality control of Samsoeum. PMID:25829771

  8. Dual enzyme activities assay by quantitative electrospray ionization quadrupole-time-of-flight mass spectrometry.

    PubMed

    Cai, Tingting; Zhang, Li; Wang, Haoyang; Zhang, Jing; Wang, Rong; Zhang, Yurong; Guo, Yinlong

    2012-01-01

    A practical and rapid method based on electrospray ionization quadrupole-time of flight mass spectrometry (ESI-Q-ToF MS) was developed for detecting activities of both acetylcholinesterase IAChEI and glutathione S-transferase (GST). The simultaneous study of these two enzyme activities is significant for studying human bio-functions, especially for those who take in toxic compounds and have a risk of disease. Here, the enzyme activities were represented by the conversion of enzymatic substrates and determined by quantitatively analyzing enzymatic substrates. Different internal standards were used to quantify each enzymatic substrate and the good linearity of calibration curves demonstrated the feasibility of the internal standards. The Michaelis-Menten constants (Km) of both GST and AChE were measured by this method and were consistent with values previously reported. Furthermore, we applied this approach to detect GST and AChE activities of whole bloods from four deceased and healthy people. The variation in enzyme activity was in accord with information from gas chromatography mass spectrometry [GC/MS). The screening of AChE and GST provided reliable results and strong forensic evidence. This method offers an alternative choice for detecting enzyme activities and is anticipated to have wide applications in pharmaceutical research and prevention in toxic compounds.

  9. Optically detected, single nanoparticle mass spectrometer with pre-filtered electrospray nanoparticle source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howder, Collin R.; Bell, David M.; Anderson, Scott L.

    2014-01-15

    An instrument designed for non-destructive mass analysis of single trapped nanoparticles is described. The heart of the instrument is a 3D quadrupole (Paul) trap constructed to give optical access to the trap center along ten directions, allowing passage of lasers for particle heating and detection, particle injection, collection of scattered or fluorescent photons for particle detection and mass analysis, and collection of particles on TEM grids for analysis, as needed. Nanoparticles are injected using an electrospray ionization (ESI) source, and conditions are described for spraying and trapping polymer particles, bare metal particles, and ligand stabilized particles with masses ranging frommore » 200 kDa to >3 GDa. Conditions appropriate to ESI and injection of different types of particles are described. The instrument is equipped with two ion guides separating the ESI source and nanoparticle trap. The first ion guide is mostly to allow desolvation and differential pumping before the particles enter the trap section of the instrument. The second is a linear quadrupole guide, which can be operated in mass selective or mass band-pass modes to limit transmission to species with mass-to-charge ratios in the range of interest. With a little experience, the design allows injection of single particles into the trap upon demand.« less

  10. Desorption electrospray ionization-mass spectrometry for the detection of analytes extracted by thin-film molecularly imprinted polymers.

    PubMed

    Van Biesen, Geert; Wiseman, Justin M; Li, Jessica; Bottaro, Christina S

    2010-09-01

    Desorption electrospray ionization-mass spectrometry (DESI-MS) is a powerful technique for the analysis of solid and liquid surfaces that has found numerous applications in the few years since its invention. For the first time, it is applied to the detection of analytes extracted by molecularly imprinted polymers (MIPs) in a thin-film format. MIPs formed with 2,4-dichlorophenoxyacetic acid (2,4-D) as the template were used for the extraction of this analyte from aqueous solutions spiked at concentrations of 0.0050-2.0 mg L(-1) (approximately 2 x 10(-8) to approximately 1 x 10(-5) M). The response was linear up to 0.50 mg L(-1), and then levelled off due to saturation of the active sites of the MIP. In MS/MS mode, the signal at 0.0050 mg L(-1) was still an order of magnitude higher than the signal of a blank. The MIP DESI-MS approach was also used for the analysis of tap water and river water spiked with 2,4-D and four analogues, which indicated that these analogues were also extracted to various extents. For practical applications of the MIP, a detection technique is required that can distinguish between these structurally similar compounds, and DESI-MS fulfills this purpose.

  11. Analysis of a variety of inorganic and organic additives in food products by ion-pairing liquid chromatography coupled to high-resolution mass spectrometry.

    PubMed

    Kaufmann, Anton; Widmer, Mirjam; Maden, Kathryn; Butcher, Patrick; Walker, Stephan

    2018-03-05

    A reversed-phase ion-pairing chromatographic method was developed for the detection and quantification of inorganic and organic anionic food additives. A single-stage high-resolution mass spectrometer (orbitrap ion trap, Orbitrap) was used to detect the accurate masses of the unfragmented analyte ions. The developed ion-pairing chromatography method was based on a dibutylamine/hexafluoro-2-propanol buffer. Dibutylamine can be charged to serve as a chromatographic ion-pairing agent. This ensures sufficient retention of inorganic and organic anions. Yet, unlike quaternary amines, it can be de-charged in the electrospray to prevent the formation of neutral analyte ion-pairing agent adducts. This process is significantly facilitated by the added hexafluoro-2-propanol. This approach permits the sensitive detection and quantification of additives like nitrate and mono-, di-, and triphosphate as well as citric acid, a number of artificial sweeteners like cyclamate and aspartame, flavor enhancers like glutamate, and preservatives like sorbic acid. This is a major advantage, since the currently used analytical methods as utilized in food safety laboratories are only capable in monitoring a few compounds or a particular category of food additives. Graphical abstract Deptotonation of ion pair agent in the electrospray interface.

  12. High-throughput method for macrolides and lincosamides antibiotics residues analysis in milk and muscle using a simple liquid-liquid extraction technique and liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-MS/MS).

    PubMed

    Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Campos Motta, Tanara Magalhães; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara

    2015-11-01

    A fast and simple method for residue analysis of the antibiotics classes of macrolides (erythromycin, azithromycin, tylosin, tilmicosin and spiramycin) and lincosamides (lincomycin and clindamycin) was developed and validated for cattle, swine and chicken muscle and for bovine milk. Sample preparation consists in a liquid-liquid extraction (LLE) with acetonitrile, followed by liquid chromatography-electrospray-tandem mass spectrometry analysis (LC-ESI-MS/MS), without the need of any additional clean-up steps. Chromatographic separation was achieved using a C18 column and a mobile phase composed by acidified acetonitrile and water. The method was fully validated according the criteria of the Commission Decision 2002/657/EC. Validation parameters such as limit of detection, limit of quantification, linearity, accuracy, repeatability, specificity, reproducibility, decision limit (CCα) and detection capability (CCβ) were evaluated. All calculated values met the established criteria. Reproducibility values, expressed as coefficient of variation, were all lower than 19.1%. Recoveries range from 60% to 107%. Limits of detection were from 5 to 25 µg kg(-1).The present method is able to be applied in routine analysis, with adequate time of analysis, low cost and a simple sample preparation protocol. Copyright © 2015. Published by Elsevier B.V.

  13. Quantitative determination of the dual COX-2/5-LOX inhibitor tryptanthrin in Isatis tinctoria by ESI-LC-MS.

    PubMed

    Danz, Henning; Baumann, Dietmar; Hamburger, Matthias

    2002-02-01

    Isatis tinctoria L. is an old European and Chinese dye plant and anti-inflammatory herb from which the potent cyclooxygenase-2 and 5-lipoxygenase inhibitor tryptanthrin (1) (indolo-[2,1-b]-quinazoline-6,12-dione) was recently isolated as one of the active principles. An HPLC method for the quantitative analysis of the compound in plant material was developed. Reproducible extraction was achieved by accelerated solvent extraction (ASE). Detection by UV at 254 and 387 nm and by electrospray-MS were compared. The low tryptanthrin content in the herb and possible interferences required isocratic high-performance liquid chromatography coupled with electrospray-MS in single ion mode. More than 70 Isatis samples of different origin were analyzed. The tryptanthrin content in leaf samples varied from 0.56 to 16.74 x 10(-3) %.

  14. Combined electrophoretic-separation and electrospray method and system

    DOEpatents

    Smith, R.D.; Olivares, J.A.

    1989-06-27

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary zone electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., [+-]2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit. 10 figs.

  15. Electrospray Ionization/Ion Mobility Spectrometer/Cylindrical Ion Trap Mass Spectrometer System for In-Situ Detection of Organic Compounds

    NASA Technical Reports Server (NTRS)

    Kanik, I.; Johnson, P. V.; Beegle, L. W.; Cooks, R. G.; Laughlin, B. C.; Hill, H. H.

    2003-01-01

    The potential of an Electrospray Ionization/Ion Mobility Spectrometer/Cylindrical Ion Trap Mass Spectrometer (ESI/IMS/CIT-MS) as an analytical instrument for analyzing material extracted from rock and soil samples as part of a suite of instruments on the proposed 2009 Mars Science Lander (MSL) will be demonstrated. This instrument will be able to identify volatile compounds as well as resident organic molecules on the parts-per-billion (ppb) level. Also, it will be able to obtain an inventory of chemical species on the surface of Mars which will result in a better understanding of ongoing surface chemistry. Finally, questions relevant to biological processes will be answered with the complete inventory of surface and near surface organic molecules that the ESI/IMS/CIT is capable of performing.

  16. Sensitive determination of RDX, nitroso-RDX metabolites, and other munitions in ground water by solid-phase extraction and isotope dilution liquid chromatography-atmospheric pressure electro-spray [correction of chemical] ionization mass spectrometry.

    PubMed

    Cassada, D A; Monson, S J; Snow, D D; Spalding, R F

    1999-06-04

    Recent improvements in the LC-MS interface have increased the sensitivity and selectivity of this instrument in the analysis of polar and thermally-labile aqueous constituents. Determination of RDX, nitroso-RDX metabolites, and other munitions was enhanced using LC-MS with solid-phase extraction, 15N3-RDX internal standard, and electrospray ionization (ESI) in negative ion mode. ESI produced a five-fold increase in detector response over atmospheric pressure chemical ionization (APCI) for the nitramine compounds, while the more energetic APCI produced more than twenty times the ESI response for nitroaromatics. Method detection limits in ESI for nitramines varied from 0.03 microgram l-1 for MNX to 0.05 microgram l-1 for RDX.

  17. A single step reversed-phase high performance liquid chromatography separation of polar and non-polar lipids.

    PubMed

    Olsson, Petter; Holmbäck, Jan; Herslöf, Bengt

    2014-11-21

    This paper reports a simple chromatographic system to separate lipids classes as well as their molecular species. By the use of phenyl coated silica as stationary phase in combination with a simple mobile phase consisting of methanol and water, all tested lipid classes elute within 30 min. Furthermore, a method to accurately predict retention times of specific lipid components for this type of chromatography is presented. Common detection systems were used, namely evaporative light scattering detection (ELSD), charged aerosol detection (CAD), electrospray mass spectrometry (ESI-MS), and UV detection. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Antibacterial colorants: characterization of prodiginines and their applications on textile materials.

    PubMed

    Alihosseini, Farzaneh; Ju, Kou-San; Lango, Jozsef; Hammock, Bruce D; Sun, Gang

    2008-01-01

    A strain of Vibrio sp. isolated from marine sediments produced large quantities of bright red pigments that could be used to dye many fibers including wool, nylon, acrylics, and silk. Characterization of the pigments by electrospray ionization mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR) revealed three prodiginine-like structures with nonpolar characteristics and low molecular mass. UV-visible spectra of the major constituent in methanol solution showed absorbance at lambda max 530 nm wavelength. The accurate mass result showed that the main isolated product has a molecular mass of m/z 323.1997. Further analysis using mass fragmentation (MS/MS), 1H NMR, COSY, HMQC NMR and DEPT confirmed the detailed structure of the pigment with an elementary composition of C20H25N3O. Fabrics dyed with the microbial prodiginines demonstrated antibacterial activity.

  19. Qualitative analysis of seized cocaine samples using desorption electrospray ionization- mass spectrometry (DESI-MS).

    PubMed

    Stojanovska, Natasha; Tahtouh, Mark; Kelly, Tamsin; Beavis, Alison; Fu, Shanlin

    2015-05-01

    Desorption electrospray ionization - mass spectrometry (DESI-MS) is a useful technique for the qualitative analysis of compounds found in seized drug material. In this study, DESI-MS was utilized in the screening analysis of illicit cocaine samples. The technique was also applied to the geographical origin determination of these samples. The limit of detection was determined to be 24.3 µg (or 3.47 µg/mm(2) ) and the analysis time was less than 1 minute per sample. The intra-day and inter-day precision for the detection of cocaine was 11 % and 42 %, respectively; therefore the quantitative data provided by DESI-MS was limited in its use for accurate determination of cocaine concentration in a sample. Using the quadrupole time-of-flight (QTOF) mass spectrometer, the presence of cocaine and impurities detected were confirmed by accurate tandem MS data. The qualitative chemical profiles obtained using DESI-MS were compared to two popular analysis techniques, GC-MS and LC-MS. The effects of a range of adulterants including caffeine, procaine, levamisole, lignocaine, paracetamol, and atropine on the detectability of cocaine were also investigated. It was found that the addition of these adulterants in a cocaine sample did not prevent the detection of the analyte itself (there was slight enhancement in some samples), which was useful in drug detection. The detection of truxillines in the seized samples by DESI-MS aided in the preliminary determination of geographical origin, i.e., Bolivian, Peruvian or Colombian leaf origin. The application of DESI-MS to the qualitative analysis and screening of seized cocaine samples demonstrates the potential and applicability of the technique to the fast chemical profiling of illicit samples. Copyright © 2014 John Wiley & Sons, Ltd.

  20. An Undergraduate Experiment for the Measurement of Perfluorinated Surfactants in Fish Liver by Liquid Chromatography-Tandem Mass Spectrometry

    ERIC Educational Resources Information Center

    Stock, Naomi L.; Martin, Jonathan W.; Ye, Yun; Mabury, Scott A.

    2007-01-01

    A laboratory experiment that provides students a hands-on introduction to the specific techniques of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and electrospray ionization is presented. The students can thus practice the analytical principles of sample extraction, detection, quantification, and quality control using a fresh fish…

  1. A NEW SW-846 METHOD: MICRO-LIQUID CHROMATOGRAPHY-ELECTROSPRAY/ION TRAP MASS SPECTROMETRY AS APPLIED TO THE DETECTION AND IDENTIFICATION OF ORGANOTINS - METHOD 8323

    EPA Science Inventory

    There is a growing body of evidence that humans and other animals (terrestrial and marine) are being exposed continually to potentially harmful species of organotins. One possible route of environmental exposure in the U.S. to organotins (specifically dibutyltin and triphenyltin)...

  2. Direct profiling of phytochemicals in tulip tissues and in vivo monitoring of the change of carbohydrate content in tulip bulbs by probe electrospray ionization mass spectrometry.

    PubMed

    Yu, Zhan; Chen, Lee Chuin; Suzuki, Hiroaki; Ariyada, Osamu; Erra-Balsells, Rosa; Nonami, Hiroshi; Hiraoka, Kenzo

    2009-12-01

    Probe electrospray ionization (PESI) is a recently developed ESI-based ionization technique which generates electrospray from the tip of a solid needle. In this study, we have applied PESI interfaced with a time of flight mass spectrometer (TOF-MS) for direct profiling of phytochemicals in a section of a tulip bulb in different regions, including basal plate, outer and inner rims of scale, flower bud and foliage leaves. Different parts of tulip petals and leaves have also been investigated. Carbohydrates, amino acids and other phytochemicals were detected. A series of in vivo PESI-MS experiments were carried out on the second outermost scales of four living tulip bulbs to monitoring the change of carbohydrate content during the first week of initial growth. The breakdown of carbohydrates was observed which was in accordance with previous reports achieved by other techniques. This study has indicated that PESI-MS can be used for rapid and direct analysis of phytochemicals in living biological systems with advantages of low sample consumption and little sample preparation. Therefore, PESI-MS can be a new choice for direct analysis/profiling of bioactive compounds or monitoring metabolic changes in living biological systems.

  3. Simultaneous determination of thirteen flavonoids from Xiaobuxin-Tang extract using high-performance liquid chromatography coupled with electrospray ionization mass spectrometry.

    PubMed

    Cen, Meifeng; Ruan, Jinxiu; Huang, Lihua; Zhang, Zhenqing; Yu, Nengjiang; Zhang, Youzhi; Cheng, Xuange; Xiong, Xiaohong; Wang, Guixiang; Zang, Linquan; Wang, Sujun

    2015-11-10

    A simple and reliable high performance liquid chromatography coupled with electrospray ionization mass spectrometry (HPLC-ESI-MS) analysis method was established to simultaneously determine thirteen flavonoids of Xiaobuxing-Tang in intestine perfusate, namely onpordin, 3'-O-methylorobol, glycitein, patuletin, genistein, luteolin, quercetin, nepitrin, quercimeritrin, daidzin, patulitrin, quercetagitrin and 3-glucosylisorhamnetin. Detection was performed on a quadrupole mass spectrometer equipped with an electrospray ionization (ESI) source operating in negative ionization mode. Negative ion ESI was used to form deprotonated molecules at m/z 315 for onpordin, m/z 299 for 3'-O-methylorobol, m/z 283 for glycitein, m/z 331 for patuletin, m/z 269 for genistein, m/z 285 for luteolin, m/z 301 for quercetin, m/z 477 for nepitrin, m/z 463 for quercimeritrin, m/z 461 for daidzin, m/z 493 for patulitrin, m/z 479 for quercetagitrin, m/z 477 for 3-glucosylisorhamnetin and m/z 609.2 for rutin. The linearity, sensitivity, selectivity, repeatability, accuracy, precision, recovery and matrix effect of the assay were evaluated. The proposed method was successfully applied to simultaneous determination of these thirteen flavonoids, and using this method, the intestinal absorption profiles of thirteen flavonoids were preliminarily predicted. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. In situ analysis of soybeans and nuts by probe electrospray ionization mass spectrometry.

    PubMed

    Petroselli, Gabriela; Mandal, Mridul K; Chen, Lee C; Hiraoka, Kenzo; Nonami, Hiroshi; Erra-Balsells, Rosa

    2015-04-01

    The probe electrospray ionization (PESI) is an ESI-based ionization technique that generates electrospray from the tip of a solid metal needle. In the present work, we describe the PESI mass spectra obtained by in situ measurement of soybeans and several nuts (peanuts, walnuts, cashew nuts, macadamia nuts and almonds) using different solid needles as sampling probes. It was found that PESI-MS is a valuable approach for in situ lipid analysis of these seeds. The phospholipid and triacylglycerol PESI spectra of different nuts and soybean were compared by principal component analysis (PCA). PCA shows significant differences among the data of each family of seeds. Methanolic extracts of nuts and soybean were exposed to air and sunlight for several days. PESI mass spectra were recorded before and after the treatment. Along the aging of the oil (rancidification), the formation of oxidated species with variable number of hydroperoxide groups could be observed in the PESI spectra. The relative intensity of oxidated triacylglycerols signals increased with days of exposition. Monitoring sensitivity of PESI-MS was high. This method provides a fast, simple and sensitive technique for the analysis (detection and characterization) of lipids in seed tissue and degree of oxidation of the oil samples. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Quantitative mass spectrometry imaging of emtricitabine in cervical tissue model using infrared matrix-assisted laser desorption electrospray ionization

    PubMed Central

    Bokhart, Mark T.; Rosen, Elias; Thompson, Corbin; Sykes, Craig; Kashuba, Angela D. M.; Muddiman, David C.

    2015-01-01

    A quantitative mass spectrometry imaging (QMSI) technique using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is demonstrated for the antiretroviral (ARV) drug emtricitabine in incubated human cervical tissue. Method development of the QMSI technique leads to a gain in sensitivity and removal of interferences for several ARV drugs. Analyte response was significantly improved by a detailed evaluation of several cationization agents. Increased sensitivity and removal of an isobaric interference was demonstrated with sodium chloride in the electrospray solvent. Voxel-to-voxel variability was improved for the MSI experiments by normalizing analyte abundance to a uniformly applied compound with similar characteristics to the drug of interest. Finally, emtricitabine was quantified in tissue with a calibration curve generated from the stable isotope-labeled analog of emtricitabine followed by cross-validation using liquid chromatography tandem mass spectrometry (LC-MS/MS). The quantitative IR-MALDESI analysis proved to be reproducible with an emtricitabine concentration of 17.2±1.8 μg/gtissue. This amount corresponds to the detection of 7 fmol/voxel in the IR-MALDESI QMSI experiment. Adjacent tissue slices were analyzed using LC-MS/MS which resulted in an emtricitabine concentration of 28.4±2.8 μg/gtissue. PMID:25318460

  6. Resolution and identification of the protein components of the photosystem II antenna system of higher plants by reversed-phase liquid chromatography with electrospray-mass spectrometric detection.

    PubMed

    Corradini, D; Huber, C G; Timperio, A M; Zolla, L

    2000-07-21

    Reversed-phase liquid chromatography (RPLC) was interfaced to mass spectrometry (MS) with an electrospray ion (ESI) source for the separation and accurate molecular mass determination of the individual intrinsic membrane proteins that comprise the photosystem II (PS II) major light-harvesting complex (LHC II) and minor (CP24, CP26 and CP29) antenna system, whose molecular masses range between 22,000 and 29,000. PS II is a supramolecular complex intrinsic of the thylacoid membrane, which plays the important role in photosynthesis of capturing solar energy, and transferring it to photochemical reaction centers where energy conversion occurs. The protein components of the PS II major and minor antenna systems were extracted from spinach thylacoid membranes and separated using a butyl-silica column eluted by an acetonitrile gradient in 0.05% (v/v) aqueous trifluoroacetic acid. On-line electrospray MS allowed accurate molecular mass determination and identification of the protein components of PS II major and minor antenna system. The proposed RPLC-ESI-MS method holds several advantages over sodium dodecyl sulfate-polyacrylamide gel electrophoresis, the conventional technique for studying membrane proteins, including a better protein separation, mass accuracy, speed and efficiency.

  7. Direct Analysis of Textile Fabrics and Dyes Using IR Matrix-Assisted Laser Desorption Electrospray Ionization (MALDESI) Mass Spectrometry

    PubMed Central

    Cochran, Kristin H.; Barry, Jeremy A.; Muddiman, David C.; Hinks, David

    2012-01-01

    The forensic analysis of textile fibers uses a variety of techniques from microscopy to spectroscopy. One such technique that is often used to identify the dye(s) within the fiber is mass spectrometry (MS). In the traditional MS method, the dye must be extracted from the fabric and the dye components are separated by chromatography prior to mass spectrometric analysis. Direct analysis of the dye from the fabric allows the omission of the lengthy sample preparation involved in extraction, thereby significantly reducing the overall analysis time. Herein, a direct analysis of dyed textile fabric was performed using the infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) source for MS. In MALDESI, an IR laser with wavelength tuned to 2.94 μm is used to desorb the dye from the fabric sample with the aid of water as the matrix. The desorbed dye molecules are then post-ionized by electrospray ionization (ESI). A variety of dye classes were analyzed from various fabrics with little to no sample preparation allowing for the identification of the dye mass and in some cases the fiber polymer. Those dyes that were not detected using MALDESI were also not observed by direct infusion ESI of the dye standard. PMID:23237031

  8. Ambient mass spectrometry: Direct analysis of dimethoate, tebuconazole, and trifloxystrobin on olive and vine leaves by desorption electrospray ionization interface.

    PubMed

    Mainero Rocca, Lucia; Cecca, Juri; L'Episcopo, Nunziata; Fabrizi, Giovanni

    2017-11-01

    A new field of application for a relatively new mass-spectrometric interface such as desorption electrospray ionization was evaluated. For this purpose, its behavior was tested versus quantitative analysis of dimethoate, trifloxystrobin, and tebuconazole directly on olive and vine leaves surface. The goal was workers exposure assessment during field re-entry operations since evidence suggests an association between chronic occupational exposure to some agrochemicals and severe adverse effects. Desorption electrospray ionization gave good response working in positive ionization mode, while numerous test were necessary for the choice of a unique blend of spray solvents suitable for all 3 substances. The best compromise, in terms of signal to noise ratios, was obtained with the CH 3 OH/H 2 O (80:20) mixture. The obvious difficulties related to the impossibility to use the internal standard were overcome through an accurate validation. Limits of detection and quantitation, dynamic ranges, matrix effects, and intraday precisions were calculated, and a small monitoring campaign was arranged to test method applicability and to evaluate potential dermal exposure. This protocol was developed in work safety field, but after a brief investigation, it was find to be suitable also for food residue evaluation. Copyright © 2017 John Wiley & Sons, Ltd.

  9. A new hybrid electrospray Fourier transform mass spectrometer: design and performance characteristics.

    PubMed

    O'connor, Peter B; Pittman, Jason L; Thomson, Bruce A; Budnik, Bogdan A; Cournoyer, Jason C; Jebanathirajah, Judith; Lin, Cheng; Moyer, Susanne; Zhao, Cheng

    2006-01-01

    A new hybrid electrospray quadrupole Fourier transform mass spectrometry (FTMS) instrument design is shown and characterized. This instrument involves coupling an electrospray source and mass-resolving quadrupole, ion accumulation, and collision cell linear ion trap system developed by MDS Sciex with a home-built ion guide and ion cyclotron resonance (ICR) cell. The iterative progression of this design is shown. The final design involves a set of hexapole ion guides to transfer the ions from the accumulation/collision trap through the magnetic field gradient and into the cell. These hexapole ion guides are separated by a thin gate valve and two conduction limits to maintain the required <10(-9) mbar vacuum for FTICR. Low-attomole detection limits for a pure peptide are shown, 220 000 resolving power in broadband mode and 820 000 resolving power in narrow-band mode are demonstrated, and mass accuracy in the <2 ppm range is routinely available provided the signal is abundant, cleanly resolved, and internally calibrated. This instrument design provides high experimental flexibility, allowing Q2 CAD, SORI-CAD, IRMPD, and ECD experiments with selected ion accumulation as well as experiments such as nozzle skimmer dissociation. Initial top-down mass spectrometry experiments on a protein is shown using ECD.

  10. Quantification of lipoic acid in plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry.

    PubMed

    Chen, Jun; Jiang, Wenming; Cai, Jia; Tao, Weixing; Gao, Xiaoling; Jiang, Xinguo

    2005-09-25

    A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of lipoic acid (LA) in human plasma. LA and the internal standard, naproxen, were extracted from a 500 microl plasma sample by one-step deproteination using acetonitrile. Chromatographic separation was performed on a Zorbax SB-C(18) Column (100 mmx3.0mm i.d. with 3.5 microm particle size) with the mobile phase consisting of acetonitrile and 0.1% acetic acid (pH 4, adjusted with ammonia solution) (65:35, v/v), and the flow rate was set at 0.3 ml/min. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via electrospray ionization (ESI) source. The method was linear over the concentration range of 5-10,000 ng/ml for LA. The intra- and inter-day precisions were less than 7% and accuracy ranged from -7.87 to 9.74% at the LA concentrations tested. The present method provides a relatively simple and sensitive assay with short turn-around time. The method has been successfully applied to a clinical pharmacokinetic study of LA in 10 healthy subjects.

  11. Small-scale purification of butyrylcholinesterase from human plasma and implementation of a μLC-UV/ESI MS/MS method to detect its organophosphorus adducts.

    PubMed

    John, Harald; Breyer, Felicitas; Schmidt, Christian; Mizaikoff, Boris; Worek, Franz; Thiermann, Horst

    2015-10-01

    Human butyrylcholinesterase (hBChE) is a serine hydrolase (EC 3.1.1.8) present in all mammalian tissues and the bloodstream. Similar to acetylcholinesterase, the enzyme reacts with organophosphorus compounds (OP) like nerve agents or pesticides that cause enzyme inhibition (BChE adducts). These adducts represent valuable biomarkers for analytical verification of OP exposure. For establishment of these mass spectrometry based methods sufficient amounts of hBChE in high purity are required. Unfortunately, commercial lots are of inappropriate purity thus favouring in-house isolation. Therefore, we developed a small scale procedure to isolate hBChE from citrate plasma. After precipitation by polyethylene glycol (8% w/v and 20% w/v PEG 6000) hBChE was purified from plasma by four consecutive chromatographic steps including anion exchange, affinity extraction and size exclusion. Protein elution was monitored on-line by UV-absorbance (280 nm) followed by continuous fractionation for off-line analysis of (1) hBChE enzyme activity by Ellman assay, (2) protein purity by gel electrophoresis, and (3) protein identity by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). Numerous major impurities separated from hBChE were identified. The purified material was used for in vitro incubation with diverse OP to establish a μ-liquid chromatography-ultra violet detection/electrospray ionization tandem-mass spectrometric method (μLC-UV/ESI MS/MS) for detection of hBChE adducts suitable for verification analysis. Analytical data for diverse OP pesticides including deuterated analogues as well as G- and V-type nerve agents and their precursor are summarized. This method was successfully applied to plasma samples provided by the Organisation for the Prohibition of Chemical Weapons (OPCW) for the 4th Biomedical Exercise. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Effects of liquid post-column addition in electrospray ionization performance in supercritical fluid chromatography-mass spectrometry.

    PubMed

    Akbal, Laura; Hopfgartner, Gérard

    2017-09-29

    In supercritical fluid chromatography coupled to atmospheric pressure ionization mass spectrometry (SFC-MS), the use of a make-up post-column is almost mandatory to avoid analyte precipitation, especially when using low percentage of modifier (<5%) in the mobile phase. Due to the specific nature of gaseous CO 2 , the tuning of the make-up conditions in electrospray becomes an important factor and can be used to tune analyte sensitivity. Neither a dilution effect (loss of signal) nor a relevant degradation of chromatographic performances is observed with the addition of a make-up at various flow-rates, up to 0.7mL/min. From supercritical conditions (1mL/min 40°C, 150bar) to gaseous state (room temperature, atmospheric pressure), the CO 2 expands around 430 times, contributing to almost 5% of the nebulizing process. In positive mode, the presence of ammonium ions either in the mobile phase or in the make-up did significantly increase the MS signal, even at basic apparent pH. The ionization performance of electrospray is influenced by the acidic buffer power of the carbon dioxide, and was found to be restricted in the apparent pH range of 3.8-7.2 in the various conditions investigated. This may challenge sensitive detection in negative mode, as illustrated for bosentan. The use of DMSO as make-up additive (up to 30%) showed a simplification of the full scan spectrum regarding the adducts. Finally, the optimization of make-up composition leads to an enhancement up to a factor of 69 on the electrospray MS response signal, for the SFC-SRM/MS analysis of HIV protease inhibitors in plasma extracted from Dried Plasma Spots. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Analysis of antibiotic fungicide kasugamycin in irrigation water by high performance liquid chromatography.

    PubMed

    Sheu, Ceshing; Chen, Shu-Chuan; Lo, Chi-Chu

    2010-07-01

    A high performance liquid chromatographic (HPLC) analysis method with an ultraviolet (UV) detector and an Aqua C18 (250 x 4.6 mm, Phenomenex) column were applied to analyze the antibiotic fungicide kasugamycin in water. An aromatic sulfonic acid spe column (Backerbond, J. T. Backer) was used to remove the interfering materials from irrigation water. A good linear relation existed between the concentration of the fungicide and the peak area, and correlation coefficient of linearity from 0.1 to 10.2 microg/mL was 0.998. The accuracies expressed as the recoveries of kasugamycin from irrigation water ranged from 112.2 to 111.7 %. The precisions expressed as relative standard deviations (RSD) were found to be below 7.0 %. The quantitative detection limit (LOQ) of kasugamycin in irrigation water was set at 2.2 microg/mL which was 2-times higher than the method detection limit (MDL) 1.03 microg/mL. Electrospray ionization-mass (ESI-MS) and fast-atom bombardment-mass (FAB-MS) were applied to compare the ability of identifying the component of the eluent peak from HPLC, and the result indicated that electrospray ionization-mass (ESI-MS) was more sensitive than fast-atom bombardment-mass (FAB-MS) in the detection of kasugamycin. There was no kasugamycin residue detected in irrigation water samples collected from paddyfields at Wufong, indicated that the residues of kasugamycin in water were less than 2.2 microg/mL, and the risk of water contamination was very low.

  14. Low pressure electrospray ionization system and process for effective transmission of ions

    DOEpatents

    Tang, Keqi [Richland, WA; Page, Jason S [Kennewick, WA; Kelly, Ryan T [Wet Richland, WA; Smith, Richard D [Richland, WA

    2010-03-02

    A system and method are disclosed that provide up to complete transmission of ions between coupled stages with low effective ion losses. A novel "interfaceless" electrospray ionization system is further described that operates the electrospray at a reduced pressure such that standard electrospray sample solutions can be directly sprayed into an electrodynamic ion funnel which provides ion focusing and transmission of ions into a mass analyzer.

  15. Nanoparticle preparation of Mefenamic acid by electrospray drying

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zolkepali, Nurul Karimah, E-mail: fitrah@salam.uitm.edu.my; Bakar, Noor Fitrah Abu, E-mail: fitrah@salam.uitm.edu.my; Anuar, Nornizar

    2014-02-24

    Nanoparticles preparation of Mefenamic acid (MA) by using an electrospray drying method was conducted in this study. Electrospray drying is a process that uses electrostatic force to disperse a conductive liquid stream into fine charged droplets through the coulomb fission of charges in the liquid and finally dry into fine particles. Electrospray drying modes operation usually in Taylor cone jet, and it was formed by controlling applied voltage and liquid flow rate. A conductive liquid (2.77–8.55μScm{sup −1}) which is MA solution was prepared by using acetone with concentration 0.041 and 0.055 M before pumping at a flow rate of 3–6ml/h.more » By applying the applied voltage at 1.3–1.5 kV, Taylor cone jet mode was formed prior to the electrospray. During electrospray drying process, solvent evaporation from the droplet was occurring that leads to coulomb disruption and may generate to nanoparticles. The dried nanoparticles were collected on a grounded substrate that was placed at varying distance from the electrospray. MA particle with size range of 100–400 nm were produced by electrospray drying process. Characterization of particles by using X-ray diffractometry (XRD) and differential scanning calorimetry (DSC) show that particles formed into polymorph I.« less

  16. TOWARD DETECTING THE 2175 A DUST FEATURE ASSOCIATED WITH STRONG HIGH-REDSHIFT Mg II ABSORPTION LINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang Peng; Zhou Hongyan; Wang Junxian

    2011-05-10

    We report detections of 39 2175 A dust extinction bump candidates associated with strong Mg II absorption lines at z{approx} 1-1.8 on quasar spectra in Sloan Digital Sky Survey (SDSS) DR3. These strong Mg II absorption line systems are detected among 2951 strong Mg II absorbers with a rest equivalent width W{sub r} {lambda}2796> 1.0 A at 1.0 < z < 1.86, which is part of a full sample of 7421 strong Mg II absorbers compiled by Prochter et al. The redshift range of the absorbers is chosen to allow the 2175 A extinction features to be completely covered withinmore » the SDSS spectrograph operation wavelength range. An upper limit of the background quasar emission redshift at z = 2.1 is set to prevent the Ly{alpha} forest lines from contaminating the sensitive spectral region for the 2175 A bump measurements. The FM90 parameterization is applied to model the optical/UV extinction curve in the rest frame of Mg II absorbers of the 2175 A bump candidates. The simulation technique developed by Jiang et al. is used to derive the statistical significance of the candidate 2175 A bumps. A total of 12 absorbers are detected with 2175 A bumps at a 5{sigma} level of statistical significance, 10 are detected at a 4{sigma} level, and 17 are detected at a 3{sigma} level. Most of the candidate bumps in this work are similar to the relatively weak 2175 A bumps observed in the Large Magellanic Cloud LMC2 supershell rather than the strong ones observed in the Milky Way. This sample has greatly increased the total number of 2175 A extinction bumps measured on SDSS quasar spectra. Follow-up observations may rule out some of the possible false detections and reveal the physical and chemical natures of 2175 A quasar absorbers.« less

  17. Toward Detecting the 2175 Å Dust Feature Associated with Strong High-redshift Mg II Absorption Lines

    NASA Astrophysics Data System (ADS)

    Jiang, Peng; Ge, Jian; Zhou, Hongyan; Wang, Junxian; Wang, Tinggui

    2011-05-01

    We report detections of 39 2175 Å dust extinction bump candidates associated with strong Mg II absorption lines at z~ 1-1.8 on quasar spectra in Sloan Digital Sky Survey (SDSS) DR3. These strong Mg II absorption line systems are detected among 2951 strong Mg II absorbers with a rest equivalent width Wr λ2796> 1.0 Å at 1.0 < z < 1.86, which is part of a full sample of 7421 strong Mg II absorbers compiled by Prochter et al. The redshift range of the absorbers is chosen to allow the 2175 Å extinction features to be completely covered within the SDSS spectrograph operation wavelength range. An upper limit of the background quasar emission redshift at z = 2.1 is set to prevent the Lyα forest lines from contaminating the sensitive spectral region for the 2175 Å bump measurements. The FM90 parameterization is applied to model the optical/UV extinction curve in the rest frame of Mg II absorbers of the 2175 Å bump candidates. The simulation technique developed by Jiang et al. is used to derive the statistical significance of the candidate 2175 Å bumps. A total of 12 absorbers are detected with 2175 Å bumps at a 5σ level of statistical significance, 10 are detected at a 4σ level, and 17 are detected at a 3σ level. Most of the candidate bumps in this work are similar to the relatively weak 2175 Å bumps observed in the Large Magellanic Cloud LMC2 supershell rather than the strong ones observed in the Milky Way. This sample has greatly increased the total number of 2175 Å extinction bumps measured on SDSS quasar spectra. Follow-up observations may rule out some of the possible false detections and reveal the physical and chemical natures of 2175 Å quasar absorbers.

  18. Liquid extraction surface analysis (LESA) of food surfaces employing chip-based nano-electrospray mass spectrometry.

    PubMed

    Eikel, Daniel; Henion, Jack

    2011-08-30

    An automated surface-sampling technique called liquid extraction surface analysis (LESA), coupled with infusion nano-electrospray high-resolution mass spectrometry and tandem mass spectrometry (MS/MS), is described and applied to the qualitative determination of surface chemical residues resulting from the artificial spraying of selected fresh fruits and vegetables with representative pesticides. Each of the targeted pesticides was readily detected with both high-resolution and full-scan collision-induced dissociation (CID) mass spectra. In the case of simazine and sevin, a mass resolution of 100,000 was insufficient to distinguish the isobaric protonated molecules for these compounds. When the surface of a spinach leaf was analyzed by LESA, trace levels of diazinon were readily detected on the spinach purchased directly from a supermarket before they were sprayed with the five-pesticide mixture. A 30 s rinse under hot running tap water appeared to quantitatively remove all remaining residues of this pesticide. Diazinon was readily detected by LESA analysis on the skin of the artificially sprayed spinach. Finally, incurred pyrimethanil at a level of 169 ppb in a batch slurry of homogenized apples was analyzed by LESA and this pesticide was readily detected by both high-resolution mass spectrometry and full-scan CID mass spectrometry, thus showing that pesticides may also be detected in whole fruit homogenized samples. This report shows that representative pesticides on fruit and vegetable surfaces present at levels 20-fold below generally allowed EPA tolerance levels are readily detected and confirmed by the title technologies making LESA-MS as interesting screening method for food safety purposes. Copyright © 2011 John Wiley & Sons, Ltd.

  19. Infection

    DTIC Science & Technology

    2010-09-01

    promote host tissue attachment and prevent sepsis represent new areas of scientific inquiry. Novel Ways to Detect Infection Swabs, needle aspiration, deep...chromosome, the bacteria emits light at 486-nm wavelength during normal bacteria respiration, and the amount of photons emitted is determined by the amount of...within 5 hours.3 Bacterial or fungal DNA is amplified by polymerase chain reaction and introduced into a mass spectroscopy by electrospray ionization

  20. QUANTITATION OF PERCHLORATE ION BY ELECTROSPRAY IONIZATION MASS SPECTROMETRY (ESI-MS) USING STABLE ASSOCIATION COMPLEXES WITH ORGANIC CATIONS AND BASES TO ENHANCE SELECTIVITY

    EPA Science Inventory

    Quantitation of trace levels of perchlorate ion in water has become a key issue since this species was discovered in water supplies around the United States. Although ion chromatographic methods presently offer the lowest limit of detection, =40 nm (4ngm1-1), chromatographic ret...

  1. Rapid analysis of controlled substances using desorption electrospray ionization mass spectrometry.

    PubMed

    Rodriguez-Cruz, Sandra E

    2006-01-01

    The recently developed technique of desorption electrospray ionization (DESI) has been applied to the rapid analysis of controlled substances. Experiments have been performed using a commercial ThermoFinnigan LCQ Advantage MAX ion-trap mass spectrometer with limited modifications. Results from the ambient sampling of licit and illicit tablets demonstrate the ability of the DESI technique to detect the main active ingredient(s) or controlled substance(s), even in the presence of other higher-concentration components. Full-scan mass spectrometry data provide preliminary identification by molecular weight determination, while rapid analysis using the tandem mass spectrometry (MS/MS) mode provides fragmentation data which, when compared to the laboratory-generated ESI-MS/MS spectral library, provide structural information and final identification of the active ingredient(s). The consecutive analysis of tablets containing different active components indicates there is no cross-contamination or interference from tablet to tablet, demonstrating the reliability of the DESI technique for rapid sampling (one tablet/min or better). Active ingredients have been detected for tablets in which the active component represents less than 1% of the total tablet weight, demonstrating the sensitivity of the technique. The real-time sampling of cannabis plant material is also presented.

  2. Characterization of physalins and fingerprint analysis for the quality evaluation of Physalis alkekengi L. var. franchetii by ultra-performance liquid chromatography combined with diode array detection and electrospray ionization tandem mass spectrometry.

    PubMed

    Zheng, Yunliang; Luan, Lianjun; Chen, Yong; Ren, Yiping; Wu, Yongjiang

    2012-12-01

    Physalins are important bioactive compounds from genus Physalis. They often occur as isomers, which makes the structural elucidation difficult. In the present study, the fragmentation behavior and UV characteristics of seven physalins from genus Physalis were firstly investigated using electrospray ionization tandem mass spectrometry (ESI-MS/MS) and diode array detection (DAD). Combined with ultra-performance liquid chromatography (UPLC) and DAD, the established approach to the structural identification of physalins by ESI-MS/MS was then applied to the analysis of Physalis alkekengi L. According to the UPLC retention behavior, the diagnostic UV spectra and the molecular structural information provided by MS/MS spectra, about 19 fingerprint peaks were identified, including 14 physalins and 5 other compounds. Finally, the established fingerprint method was applied to the analysis of 31 P. alkekengi L. samples collected from different locations, which reflected their similar chemical constituent properties. The proposed method provides a scientific and technical platform to the herbal industry for quality control and safety assurance of herbal preparations that contain this class of physalins. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. High-performance liquid chromatography with diode array detection coupled to electrospray time-of-flight and ion-trap tandem mass spectrometry to identify phenolic compounds from a lemon verbena extract.

    PubMed

    Quirantes-Piné, R; Funes, L; Micol, V; Segura-Carretero, A; Fernández-Gutiérrez, A

    2009-07-10

    High-performance liquid chromatography with diode array and electrospray ionization mass spectrometric detection was used to carry out the comprehensive characterization of a lemon verbena extract with demonstrated antioxidant and antiinflammatory activity. Two different MS techniques have been coupled to HPLC: on one hand, time-of-flight mass spectrometry, and on the other hand, tandem mass spectrometry on an ion-trap. The use of a small particle size C18 column (1.8 microm) provided a great resolution and made possible the separation of several isomers. The UV-visible spectrophotometry was used to delimit the class of phenolic compound and the accurate mass measurements on time-of-flight spectrometer enabled to identify the compounds present in the extract. Finally, the fragmentation pattern obtained in MS-MS experiments confirmed the proposed structures. This procedure was able to determine many well-known phenolic compounds present in lemon verbena such as verbascoside and its derivatives, diglucuronide derivatives of apigenin and luteolin, and eukovoside. Also gardoside, verbasoside, cistanoside F, theveside, campneoside I, chrysoeriol-7-diglucuronide, forsythoside A and acacetin-7-diglucuronide were found for the first time in lemon verbena.

  4. Identification and characterization of anthocyanins in yard-long beans (Vigna unguiculata ssp. sesquipedalis L.) by High-performance liquid chromatography with diode array detection and electrospray ionization/mass spectrometry (HPLC-DAD-ESI/MS) analysis.

    PubMed

    Ha, Tae Joung; Lee, Myoung-Hee; Park, Chang-Hwan; Pae, Suk-Bok; Shim, Kang-Bo; Ko, Jong-Min; Shin, Sang-Ouk; Baek, In-Youl; Park, Keum-Yong

    2010-02-24

    Anthocyanins play an important role in physiological functions related to human health. The objective of this study was to investigate the profiles of anthocyanins in the immature purple pods and black seeds of yard-long beans ( Vigna unguiculata ssp. sesquipedalis L.) using high-performance liquid chromatography (HPLC) with diode array detection and electrospray ionization/mass spectrometry (DAD-ESI/MS) analysis. The individual anthocyanins were identified by comparing their mass spectrometric data and retention times. In the purple pods, five individual anthocyanins were identified: delphinidin-3-O-glucoside (2), cyanidin-3-O-sambubioside (4), cyanidin-3-O-glucoside (5), pelargonidin-3-O-glucoside (7), and peonidin-3-O-glucoside (8). From the black seed coat of the yard-long beans, seven anthocyanins were identified, including delphinidin-3-O-galactoside (1), cyanidin-3-O-galactoside (3), petunidin-3-O-glucoside (6), and malvidin-3-O-glucoside (9), together with compounds 2, 5, and 8. In this study, we report for the first time anthocyanin profiles for the pod and seed coat of yard-long beans.

  5. Simultaneous analysis of strychnine and brucine and their major metabolites by liquid chromatography-electrospray ion trap mass spectrometry.

    PubMed

    Chen, Xueguo; Lai, Yongquan; Cai, Zongwei

    2012-04-01

    A liquid chromatography-electrospray ionization-ion trap mass spectrometry (LC-ESI-ITMS) method was developed for the simultaneous analysis of strychnine, brucine and their major metabolites. Strychnine and brucine were individually incubated with rat liver S9 fraction. The incubation samples were pooled together and analyzed with LC-ESI-ITMS in positive ion and full-scan detection mode. The calibration curves of strychnine and brucine in rat liver showed good linearity in ranges of 0.020 to 8.0 µg/mL for strychnine and 0.020 to 8.5 µg/mL for brucine. The limits of detections were both 0.008 µg/mL and the recoveries were 88.3 and 83.2% for strychnine and brucine, respectively. Two metabolites were identified as strychnine N-oxide and brucine N-oxide by comparing the molecular mass, retention time, full-scan mass spectra, tandem MS and MS(3) spectra with those of strychnine and brucine. The developed method provided high sensitivity and selectivity for the determination of poisonous alkaloids and their major metabolites and can be applied in the determination of samples in forensic and clinically toxicological cases.

  6. A simple, fast and sensitive screening LC-ESI-MS/MS method for antibiotics in fish.

    PubMed

    Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A

    2017-01-15

    The objective of this study was to develop and validate a fast, sensitive and simple liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the screening of six classes of antibiotics (aminoglycosides, beta-lactams, macrolides, quinolones, sulfonamides and tetracyclines) in fish. Samples were extracted with trichloroacetic acid. LC separation was achieved on a Zorbax Eclipse XDB C18 column and gradient elution using 0.1% heptafluorobutyric acid in water and acetonitrile as mobile phase. Analysis was carried out in multiple reaction monitoring mode via electrospray interface operated in the positive ionization mode, with sulfaphenazole as internal standard. The method was suitable for routine screening purposes of 40 antibiotics, according to EC Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines, taking into consideration threshold value, cut-off factor, detection capability, limit of detection, sensitivity and specificity. Real fish samples (n=193) from aquaculture were analyzed and 15% were positive for enrofloxacin (quinolone), one of them at a higher concentration than the level of interest (50µgkg -1 ), suggesting possible contamination or illegal use of that antibiotic. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Anticodeine aptamer immobilized on a Whatman cellulose paper for thin-film microextraction of codeine from urine followed by electrospray ionization ion mobility spectrometry.

    PubMed

    Hashemian, Zahra; Khayamian, Taghi; Saraji, Mohammad

    2015-02-01

    A combination of thin-film microextaction based on an aptamer immobilized on modified Whatman cellulose paper followed by electrospray ionization ion mobility spectrometry has been developed for the analysis of codeine in urine samples. The immobilization is based on the covalent linking of an amino-modified anticodeine aptamer to aldehyde groups of the oxidized cellulose paper. The covalent bonds were examined by infrared spectroscopy and elemental analysis. The effect of the extraction parameters, including the elution conditions (solvent type and volume), extraction time, and extraction temperature, on the extraction efficiency were investigated. Under the optimized conditions, the linear dynamic range was found to be 10-300 ng/mL with a detection limit of 3.4 ng/mL for codeine in urine. The relative standard deviation was 6.8% for three replicate measurements of codeine at 100 ng/mL in urine. Furthermore, the samples were analyzed with a standard method for the analysis of codeine using high-performance liquid chromatography with ultraviolet detection. The comparison of the results validates the accuracy of the proposed method as an alternative method for the analysis of codeine in urine samples.

  8. A simple and selective method for the measurement of azadirachtin and related azadirachtoid levels in fruits and vegetables using liquid chromatography electrospray ionization tandem mass spectrometry.

    PubMed

    Sarais, Giorgia; Caboni, Pierluigi; Sarritzu, Erika; Russo, Mariateresa; Cabras, Paolo

    2008-05-14

    Neem-based insecticides containing azadirachtin and related azadirachtoids are widely used in agriculture. Here, we report an analytical method for the rapid and accurate quantification of the insecticide azadirachtin A and B and other azadirachtoids such as salannin, nimbin, and their deacetylated analogues on tomatoes and peaches. Azadirachtoids were extracted from fruits and vegetables with acetonitrile. Using high-performance liquid chromatography/electrospray ionization tandem mass spectrometer, azadirachtoids were selectively detected monitoring the multiple reaction transitions of sodium adduct precursor ions. For azadirachtin A, calibration was linear over a working range of 1-1000 microg/L with r > 0.996. The limit of detection and limit of quantification for azadirachtin A were 0.4 and 0.8 microg/kg, respectively. The presence of interfering compounds in the peach and tomato extracts was evaluated and found to be minimal. Because of the linear behavior, it was concluded that the multiple reaction transitions of sodium adduct ions can be used for analytical purposes, that is, for the identification and quantification of azadirachtin A and B and related azadirachtoids in fruit and vegetable extracts at trace levels.

  9. Characterization of alkaloids in Sophora flavescens Ait. by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Liu, Guoqiang; Dong, Jing; Wang, Hong; Hashi, Yuki; Chen, Shizhong

    2011-04-05

    Sophora flavescens Ait., a well-known Chinese herbal medicine, is widely used in clinical practice for the treatment of viral hepatitis, cancer, gastrointestinal hemorrhage, and skin diseases. This paper is the first report on a method based on the combined use of high-performance liquid chromatography, photodiode array detection, and electrospray ionization tandem mass spectrometry for the comprehensive and systematic separation and characterization of bioactive alkaloids in Sophora flavescens Ait. A total of 22 constituents were identified on the basis of the extracted ion chromatograms for different [M+H](+) ions of the alkaloids present in S. flavescens Ait. Among these, 5 constituents were unambiguously identified by comparing the experimental data on their retention times and MS(n) spectra with those of the authentic compounds, and 17 other constituents were tentatively identified on the basis of their MS(n) fragmentation behaviors and/or molecular weight information from literatures. Furthermore, some characteristic fragmentation pathways of the alkaloids in S. flavescens Ait. were detected and examined. This information may be useful for characterizing the bioactive alkaloids present in S. flavescens Ait. and for possible applications in formulations. Copyright © 2010 Elsevier B.V. All rights reserved.

  10. G-index: A new metric to describe dynamic refractive index effects in HPLC absorbance detection.

    PubMed

    Kraiczek, Karsten G; Rozing, Gerard P; Zengerle, Roland

    2018-09-01

    High performance liquid chromatography (HPLC) with a solvent gradient and absorbance detection is one of the most widely used methods in analytical chemistry. The observed absorbance baseline is affected by the changes in the refractive index (RI) of the mobile phase. Near the limited of detection, this complicates peak quantitation. The general aspects of these RI-induced apparent absorbance effects are discussed. Two different detectors with fundamentally different optics and flow cell concepts, a variable-wavelength detector equipped with a conventional flow cell and a diode-array detector equipped with a liquid core waveguide flow cell, are compared with respect to their RI behavior. A simple method to separate static - partly unavoidable - RI effects from dynamic RI effects is presented. It is shown that the dynamic RI behavior of an absorbance detector can be well described using a single, relatively easy-to-determine metric called the G-index. The G-index is typically in the order of a few seconds and its sign depends on the optical flow cell concept. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Liquid chromatography/electrospray ionization tandem mass spectrometry analysis of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX).

    PubMed

    Pan, Xiaoping; Zhang, Baohong; Tian, Kang; Jones, Lindsey E; Liu, Jun; Anderson, Todd A; Wang, Jia-Sheng; Cobb, George P

    2006-01-01

    A quantitative liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method was developed for the analysis of the explosive, octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). In negative ionization mode, HMX forms an acetate adduct ion [M + CH(3)COO](-), m/z 355, in the presence of a small amount of acetic acid in the mobile phase. The ESI collision-induced dissociation (CID) spectrum of m/z 355 was acquired and the transitions m/z 355 --> 147 and m/z 355 --> 174 were chosen for the determination of HMX in samples. Using this quantification technique, the method detection limit was 1.57 microg/L and good linearity was achieved in the range 5-500 microg/L. This method will help to unambiguously analyze environmentally relevant concentrations of HMX. Copyright (c) 2006 John Wiley & Sons, Ltd.

  12. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, Richard D. [Richland, WA; Udseth, Harold R. [Richland, WA; Olivares, Jose A. [Los Alamos, NM

    1994-10-18

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit.

  13. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, R.D.; Udseth, H.R.; Olivares, J.A.

    1994-10-18

    A system and method for analyzing molecular constituents of a composition sample include: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g.,{+-}2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit. 21 figs.

  14. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, R.P.; Udseth, H.R.; Olivares, J.A.

    1989-12-05

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5--100 kVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., [+-]2--8 kVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit. 21 figs.

  15. Combined electrophoresis-electrospray interface and method

    DOEpatents

    Smith, Richard P.; Udseth, Harold R.; Olivares, Jose A.

    1989-01-01

    A system and method for analyzing molecular constituents of a composition sample includes: forming a solution of the sample, separating the solution by capillary electrophoresis into an eluent of constituents longitudinally separated according to their relative electrophoretic mobilities, electrospraying the eluent to form a charged spray in which the molecular constituents have a temporal distribution; and detecting or collecting the separated constituents in accordance with the temporal distribution in the spray. A first high-voltage (e.g., 5-100 KVDC) is applied to the solution. The spray is charged by applying a second high voltage (e.g., .+-.2-8 KVDC) between the eluent at the capillary exit and a cathode spaced in front of the exit. A complete electrical circuit is formed by a conductor which directly contacts the eluent at the capillary exit, or by conduction through a sheath electrode discharged in an annular sheath flow about the capillary exit.

  16. Selective Pyroelectric Detection of Millimetre Waves Using Ultra-Thin Metasurface Absorbers

    PubMed Central

    Kuznetsov, Sergei A.; Paulish, Andrey G.; Navarro-Cía, Miguel; Arzhannikov, Andrey V.

    2016-01-01

    Sensing infrared radiation is done inexpensively with pyroelectric detectors that generate a temporary voltage when they are heated by the incident infrared radiation. Unfortunately the performance of these detectors deteriorates for longer wavelengths, leaving the detection of, for instance, millimetre-wave radiation to expensive approaches. We propose here a simple and effective method to enhance pyroelectric detection of the millimetre-wave radiation by combining a compact commercial infrared pyro-sensor with a metasurface-enabled ultra-thin absorber, which provides spectrally- and polarization-discriminated response and is 136 times thinner than the operating wavelength. It is demonstrated that, due to the small thickness and therefore the thermal capacity of the absorber, the detector keeps the high response speed and sensitivity to millimetre waves as the original infrared pyro-sensor does against the regime of infrared detection. An in-depth electromagnetic analysis of the ultra-thin resonant absorbers along with their complex characterization by a BWO-spectroscopy technique is presented. Built upon this initial study, integrated metasurface absorber pyroelectric sensors are implemented and tested experimentally, showing high sensitivity and very fast response to millimetre-wave radiation. The proposed approach paves the way for creating highly-efficient inexpensive compact sensors for spectro-polarimetric applications in the millimetre-wave and terahertz bands. PMID:26879250

  17. Combined Atomic Force Microscope-Based Topographical Imaging and Nanometer Scale Resolved Proximal Probe Thermal Desorption/Electrospray Ionization-Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovchinnikova, Olga S; Nikiforov, Maxim; Bradshaw, James A

    2011-01-01

    Nanometer scale proximal probe thermal desorption/electrospray ionization mass spectrometry (TD/ESI-MS) was demonstrated for molecular surface sampling of caffeine from a thin film using a 30 nm diameter nano-thermal analysis (nano-TA) probe tip in an atomic force microscope (AFM) coupled via a vapor transfer line and ESI interface to a MS detection platform. Using a probe temperature of 350 C and a spot sampling time of 30 s, conical desorption craters 250 nm in diameter and 100 nm deep were created as shown through subsequent topographical imaging of the surface within the same system. Automated sampling of a 5 x 2more » array of spots, with 2 m spacing between spots, and real time selective detection of the desorbed caffeine using tandem mass spectrometry was also demonstrated. Estimated from the crater volume (~2x106 nm3), only about 10 amol (2 fg) of caffeine was liberated from each thermal desorption crater in the thin film. These results illustrate a relatively simple experimental setup and means to acquire in automated fashion sub-micrometer scale spatial sampling resolution and mass spectral detection of materials amenable to TD. The ability to achieve MS-based chemical imaging with 250 nm scale spatial resolution with this system is anticipated.« less

  18. Rapid Detection of Necrosis in Breast Cancer with Desorption Electrospray Ionization Mass Spectrometry

    PubMed Central

    Tata, Alessandra; Woolman, Michael; Ventura, Manuela; Bernards, Nicholas; Ganguly, Milan; Gribble, Adam; Shrestha, Bindesh; Bluemke, Emma; Ginsberg, Howard J.; Vitkin, Alex; Zheng, Jinzi; Zarrine-Afsar, Arash

    2016-01-01

    Identification of necrosis in tumors is of prognostic value in treatment planning, as necrosis is associated with aggressive forms of cancer and unfavourable outcomes. To facilitate rapid detection of necrosis with Mass Spectrometry (MS), we report the lipid MS profile of necrotic breast cancer with Desorption Electrospray Ionization Mass Spectrometry (DESI-MS) imaging validated with statistical analysis and correlating pathology. This MS profile is characterized by (1) the presence of the ion of m/z 572.48 [Cer(d34:1) + Cl]− which is a ceramide absent from the viable cancer subregions; (2) the absence of the ion of m/z 391.25 which is present in small abundance only in viable cancer subregions; and (3) a slight increase in the relative intensity of known breast cancer biomarker ions of m/z 281.25 [FA(18:1)-H]− and 303.23 [FA(20:4)-H]−. Necrosis is accompanied by alterations in the tissue optical depolarization rate, allowing tissue polarimetry to guide DESI-MS analysis for rapid MS profiling or targeted MS imaging. This workflow, in combination with the MS profile of necrosis, may permit rapid characterization of necrotic tumors from tissue slices. Further, necrosis-specific biomarker ions are detected in seconds with single MS scans of necrotic tumor tissue smears, which further accelerates the identification workflow by avoiding tissue sectioning and slide preparation. PMID:27734938

  19. [Simultaneous determination of nine perfluorinated compound precursors in atmospheric precipitation by solid phase extraction and ultra performance liquid chromatography with tandem mass spectrometry].

    PubMed

    Zhang, Ming; Tang, Fangliang; Xu, Jianfen; Yu, Bo; Zhang, Wei; Yao, Jianliang; Hu, Minhua

    2017-10-08

    A high-throughput detection method has been developed for the determination of nine perfluorinated compound precursors (PFCPs) in atmospheric precipitation by solid phase extraction-ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (SPE-UPLC-ESI-MS/MS). The atmospheric precipitation samples were concentrated and purified with HLB solid phase extraction cartridges. The UPLC separation was performed on an HSS T 3 column (100 mm×2.1 mm, 1.7 μm) utilizing a gradient elution program of methanol and water as the mobile phases at a flow rate of 0.2 mL/min. The MS/MS detection was performed under negative electrospray ionization (ESI - ) in multiple reaction monitoring (MRM) mode. Good linearity was observed in the range of 0.05-5.00 μg/L, 0.50-50.0 μg/L or 5.00-500 μg/L with correlation coefficients from 0.9921 to 0.9995. The limits of detection (LODs) for the nine perfluorinated compound precursors were in the ranges of 0.05-7.9 ng/L. The recoveries ranged from 76.0% to 106% with the relative standard deviations between 0.72% and 13.7%. This method is characterized by high sensitivity and precision, extensive analytical range and quick analytical rate, and can be applied for the analysis of perfluorinated compound precursors in atmospheric precipitation.

  20. Analysis of wastewater samples by direct combination of thin-film microextraction and desorption electrospray ionization mass spectrometry.

    PubMed

    Strittmatter, Nicole; Düring, Rolf-Alexander; Takáts, Zoltán

    2012-09-07

    An analysis method for aqueous samples by the direct combination of C18/SCX mixed mode thin-film microextraction (TFME) and desorption electrospray ionization mass spectrometry (DESI-MS) was developed. Both techniques make analytical workflow simpler and faster, hence the combination of the two techniques enables considerably shorter analysis time compared to the traditional liquid chromatography mass spectrometry (LC-MS) approach. The method was characterized using carbamazepine and triclosan as typical examples for pharmaceuticals and personal care product (PPCP) components which draw increasing attention as wastewater-derived environmental contaminants. Both model compounds were successfully detected in real wastewater samples and their concentrations determined using external calibration with isotope labeled standards. Effects of temperature, agitation, sample volume, and exposure time were investigated in the case of spiked aqueous samples. Results were compared to those of parallel HPLC-MS determinations and good agreement was found through a three orders of magnitude wide concentration range. Serious matrix effects were observed in treated wastewater, but lower limits of detection were still found to be in the low ng L(-1) range. Using an Orbitrap mass spectrometer, the technique was found to be ideal for screening purposes and led to the detection of various different PPCP components in wastewater treatment plant effluents, including beta-blockers, nonsteroidal anti-inflammatory drugs, and UV filters.

  1. Characterisation of a proposed internet synthesis of N,N-dimethyltryptamine using liquid chromatography/electrospray ionisation tandem mass spectrometry.

    PubMed

    Martins, Cláudia P B; Freeman, Sally; Alder, John F; Brandt, Simon D

    2009-08-14

    The psychoactive properties of N,N-dimethyltryptamine (DMT) are known to induce altered states of consciousness in humans. These properties attract great interest from clinical, neuroscientific, clandestine and forensic communities. The Breath of Hope Synthesis was reported on an internet website as a convenient two-step methodology for the preparation of DMT. The analytical characterisation of the first stage was the subject of previous publications by the authors and involved the thermal decarboxylation of tryptophan and the formation of tryptamine. The present study reports on the characterisation of the second step of this procedure which was based on the methylation of tryptamine. This employed methyl iodide and benzyltriethylammonium chloride/sodium hydroxide as a phase transfer catalyst. The reaction product was characterised by liquid chromatography/electrospray ionisation tandem mass spectrometry and orthogonal acceleration time-of-flight mass spectrometry. Quantitative evaluation was carried out in positive multiple reaction monitoring mode (MRM), which included synthesis of the identified reaction products. MRM screening of the product did not lead to the detection of DMT. Instead, 11.1% tryptamine starting material, 21.0% N,N,N-trimethyltryptammonium iodide (TMT) and 47.4% 1-N-methyl-TMT were detected. A 0.5% trace of the monomethylated N-methyltryptamine was also detected. This study demonstrated the impact on product purity of doubtful synthetic methodologies discussed on the internet.

  2. Electrosprayed nanoparticles for drug delivery and pharmaceutical applications

    PubMed Central

    Sridhar, Radhakrishnan; Ramakrishna, Seeram

    2013-01-01

    Nanotechnology based Pharma has emerged significantly and has influenced the Pharma industry up to a considerable extent. Nanoparticles technology holds a good share of the nanotech Pharma and is significant in comparison with the other domains. Electrospraying technology answers the potential needs of nanoparticle production such as scalability, reproducibility, effective encapsulation etc. Many drugs have been electrosprayed with and without polymer carriers. Drug release characteristics are improved with the incorporation of biodegradable polymer carriers which sustain the release of encapsulated drug. Electrospraying is acknowledged as an important technique for the preparation of nanoparticles with respect to pharmaceutical applications. Herein we attempted to consolidate the reports pertaining to electrospraying and their corresponding therapeutic application area. PMID:23512013

  3. Electrical and optical performance of midwave infrared InAsSb heterostructure detectors

    NASA Astrophysics Data System (ADS)

    Gomółka, Emilia; Kopytko, Małgorzata; Markowska, Olga; Michalczewski, Krystian; Kubiszyn, Łukasz; Kębłowski, Artur; Jureńczyk, Jarosław; Gawron, Waldemar; Martyniuk, Piotr Marcin; Piotrowski, Józef; Rutkowski, Jarosław; Rogalski, Antoni

    2018-02-01

    We investigate the high-operating temperature performance of InAsSb/AlSb heterostructure detectors with cutoff wavelengths near 5 μm at 230 K. The devices have been fabricated with different types of absorbing layers: nominally undoped absorber (with n-type conductivity), and both n- and p-type doped. The results show that the device performance strongly depends on absorber layer type. Generally, the p-type absorber provides higher values of current responsivity than the n-type absorber, but at the same time also higher values of dark current. The device with the nominally undoped absorbing layer shows moderate values of both current responsivity and dark current. Resulting detectivities D * of nonimmersed devices vary from 2 × 109 to 5 × 109 cm Hz1/2 W ? 1 at 230 K, which is easily achievable with a two-stage thermoelectric cooler. Optical immersion increases the detectivity up to 5 × 1010 cm Hz1/2 W ? 1.

  4. Fault Detection for Automotive Shock Absorber

    NASA Astrophysics Data System (ADS)

    Hernandez-Alcantara, Diana; Morales-Menendez, Ruben; Amezquita-Brooks, Luis

    2015-11-01

    Fault detection for automotive semi-active shock absorbers is a challenge due to the non-linear dynamics and the strong influence of the disturbances such as the road profile. First obstacle for this task, is the modeling of the fault, which has been shown to be of multiplicative nature. Many of the most widespread fault detection schemes consider additive faults. Two model-based fault algorithms for semiactive shock absorber are compared: an observer-based approach and a parameter identification approach. The performance of these schemes is validated and compared using a commercial vehicle model that was experimentally validated. Early results shows that a parameter identification approach is more accurate, whereas an observer-based approach is less sensible to parametric uncertainty.

  5. Ultrasensitive Laser Spectroscopy in Solids: Single-Molecule Detection

    DTIC Science & Technology

    1989-10-25

    spite of detection intensity constraints necessary to avoid power broadening, the optical absorption spectrum of single molecules of pentacene In p...molecule detection, or SMD) would provide a useful tool for the study of local host-absorber interactions where tihe absorbing ,ontor is essentially at...modulation techniques 7. 8 for the model system composed of pentacene substitutional impurities in p-terphenyl crystals at 1.5K. The pontacene molecules can

  6. Multi-target determination of organic ultraviolet absorbents in organism tissues by ultrasonic assisted extraction and ultra-high performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Peng, Xianzhi; Jin, Jiabin; Wang, Chunwei; Ou, Weihui; Tang, Caiming

    2015-03-06

    A sensitive and reliable method was developed for multi-target determination of 13 most widely used organic ultraviolet (UV) absorbents (including UV filters and UV stabilizers) in aquatic organism tissues. The organic UV absorbents were extracted using ultrasonic-assisted extraction, purified via gel permeation chromatography coupled with silica gel column chromatography, and determined by ultra-high performance liquid chromatography-tandem mass spectrometry. Recoveries of the UV absorbents from organism tissues mostly ranged from 70% to 120% from fish filet with satisfactory reproducibility. Method quantification limits were 0.003-1.0ngg(-1) dry weight (dw) except for 2-ethylhexyl 4-methoxycinnamate. This method has been applied to analysis of the UV absorbents in wild and farmed aquatic organisms collected from the Pearl River Estuary, South China. 2-Hydroxy-4-methoxybenzophenone and UV-P were frequently detected in both wild and farmed marine organisms at low ngg(-1)dw. 3-(4-Methylbenzylidene)camphor and most of the benzotriazole UV stabilizers were also frequently detected in maricultured fish. Octocrylene and 2-ethylhexyl 4-methoxycinnamate were not detected in any sample. This work lays basis for in-depth study about bioaccumulation and biomagnification of the UV absorbents in marine environment. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. HPLC-DAD-ESI/MS identification of light harvesting and light screening pigments in the lake sediments at Edmonson Point.

    PubMed

    Giovannetti, Rita; Alibabaei, Leila; Zannotti, Marco; Ferraro, Stefano; Petetta, Laura

    2013-01-01

    The composition of sedimentary pigments in the Antarctic lake at Edmonson Point has been investigated and compared with the aim to provide a useful analytical method for pigments separation and identification, providing reference data for future assessment of possible changes in environmental conditions. Reversed phase high performance liquid chromatography (HPLC) with electrospray-mass spectrometry (ESI-MS) detection and diode array detection (DAD) has been used to identify light screening and light harvesting pigments. The results are discussed in terms of local environmental conditions.

  8. Identification of Pathogenic Vibrio Species by Multilocus PCR-Electrospray Ionization Mass Spectrometry and Its Application to Aquatic Environments of the Former Soviet Republic of Georgia

    DTIC Science & Technology

    2010-03-01

    9 different Vibrio species were detected, 114 (41%) samples were positive for V. cholerae , and 5 (0.8%) samples were positive for the cholera toxin A... Vibrio species were detected, 114 (41%) samples were positive for V. cholerae , and 5 (0.8%) samples were positive for the cholera toxin A gene (ctxA...members include Vibrio cholerae , the causative agent of cholera , and Vibrio para- haemolyticus and Vibrio vulnificus, which have been implicated in

  9. Detection of dehalogenation impurities in organohalogenated pharmaceuticals by UHPLC-DAD-HRESIMS.

    PubMed

    Regalado, Erik L; Dermenjian, Renee K; Joyce, Leo A; Welch, Christopher J

    2014-04-01

    The presence of dehalogenated impurities is often observed in halogen-containing pharmaceuticals, and can present a difficult analytical challenge, as the chromatographic behavior of the halogenated drug and the hydrogen-containing analog can be quite similar. In this study we describe the chromatographic separation and unambiguous identification of dehalogenation impurities or associated isomers in organohalogenated pharmaceuticals using UHPLC with a pentafluorophenyl column coupled with diode-array and high resolution electrospray ionization mass spectrometry detection (UHPLC-DAD-HRESIMS). Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Photocatalytic Oxidation of Isoprene on Hydrated Atmospheric Mineral Dusts

    NASA Astrophysics Data System (ADS)

    Hoffmann, M. R.; Kameel, F. R.; Colussi, A. J.

    2011-12-01

    Mineral dust aerosols, an important fraction in the tropospheric aerosol budget, contain transition metal-based semiconductor particles that absorb light and may support diverse chemical transformations. Dust aerosol is primary, mostly originates from deserts, but includes fly ash emitted by power plants, and can be carried over long distances. We propose that such semiconductor particles may produce secondary organic aerosol (SOA) via surface-activated photochemical processes in aqueous media. Isoprene, the most abundant anthropogenic VOC is deemed to be incorporated into SOA by various mechanisms that remain to be fully characterized. We suggest that condensed-phase chemistry, in addition to gas-phase transformations, plays an important role in SOA formation. Isoprene is only slightly soluble in water, but it would react at diffusionally-controlled rates with photochemically generated OH-radicals in aqueous phase to produce more complex, polar compounds via oxidation and polymerization processes. We have found that the similar products are formed in the photolysis of aqueous hydrogen peroxide solutions or titanium dioxide suspensions in the presence of dissolved isoprene, as revealed by HPLC analysis with online high-resolution positive ion electrospray ionization mass spectrometric detection, and 1H and 13C nuclear magnetic resonance spectrometry. In contrast, hematite suspensions display negligible photocatalytic activity toward isoprene oxidation. These results suggest that atmospheric heterogeneous semiconductor photocatalysis of isoprene may play a significant role in global secondary organic aerosol formation under overly dusty conditions. Full product characterization is underway that aims at identifying species that may have adverse health/respiratory effects.

  11. Formation of nitrogen-containing oligomers by methylglyoxal and amines in simulated evaporating cloud droplets.

    PubMed

    De Haan, David O; Hawkins, Lelia N; Kononenko, Julia A; Turley, Jacob J; Corrigan, Ashley L; Tolbert, Margaret A; Jimenez, Jose L

    2011-02-01

    Reactions of methylglyoxal with amino acids, methylamine, and ammonium sulfate can take place in aqueous aerosol and evaporating cloud droplets. These processes are simulated by drying droplets and bulk solutions of these compounds (at low millimolar and 1 M concentrations, respectively) and analyzing the residuals by scanning mobility particle sizing, nuclear magnetic resonance, aerosol mass spectrometry (AMS), and electrospray ionization MS. The results are consistent with imine (but not diimine) formation on a time scale of seconds, followed by the formation of nitrogen-containing oligomers, methylimidazole, and dimethylimidazole products on a time scale of minutes to hours. Measured elemental ratios are consistent with imidazoles and oligomers being major reaction products, while effective aerosol densities suggest extensive reactions take place within minutes. These reactions may be a source of the light-absorbing, nitrogen-containing oligomers observed in urban and biomass-burning aerosol particles.

  12. Elastomeric Microchip Electrospray Emitter for Stable Cone-Jet Mode Operation in the Nano-Flow Regime

    PubMed Central

    Kelly, Ryan T.; Tang, Keqi; Irimia, Daniel; Toner, Mehmet; Smith, Richard D.

    2009-01-01

    Despite widespread interest in combining lab-on-a-chip technologies with mass spectrometry (MS)-based analyses, the coupling of microfluidics to electrospray ionization (ESI)-MS remains challenging. We report a robust, integrated poly(dimethylsiloxane) microchip interface for ESI-MS using simple and widely accessible microfabrication procedures. The interface uses an auxiliary channel to provide electrical contact for the stable cone-jet electrospray without sample loss or dilution. The electric field at the channel terminus is enhanced by two vertical cuts that cause the interface to taper to a line rather than to a point, and the formation of a small Taylor cone at the channel exit ensures sub-nL post-column dead volumes. Cone-jet mode electrospray was demonstrated for up to 90% aqueous solutions and for extended durations. Comparable ESI-MS sensitivities were achieved using both microchip and conventional fused silica capillary emitters, but stable cone-jet mode electrosprays could be established over a far broader range of flow rates (from 50-1000 nL/min) and applied potentials using the microchip emitters. This attribute of the microchip emitter should simplify electrospray optimization and make the stable electrospray more resistant to external perturbations. PMID:18419138

  13. Study of superhydrophobic electrosprayed catalyst layers using a localized reference electrode technique

    NASA Astrophysics Data System (ADS)

    Chaparro, A. M.; Ferreira-Aparicio, P.; Folgado, M. A.; Brightman, E.; Hinds, G.

    2016-09-01

    The performance of electrosprayed cathode catalyst layers in a polymer electrolyte membrane fuel cell (PEMFC) is studied using a localized reference electrode technique. Single cells with an electrosprayed cathode catalyst layer show an increase of >20% in maximum power density under standard testing conditions, compared with identical cells assembled with a conventional, state-of-the-art, gas diffusion cathode. When operated at high current density (1.2 A cm-2) the electrosprayed catalyst layers show more homogeneous distribution of the localized cathode potential, with a standard deviation from inlet to outlet of <50 mV, compared with 79 mV for the conventional gas diffusion cathode. Higher performance and homogeneity of cell response is attributed to the superhydrophobic nature of the macroporous electrosprayed catalyst layer structure, which enhances the rate of expulsion of liquid water from the cathode. On the other hand, at low current densities (<0.5 A cm-2), the electrosprayed layers exhibit more heterogeneous distribution of cathode potential than the conventional cathodes; this behavior is attributed to less favorable kinetics for oxygen reduction in very hydrophobic catalyst layers. The optimum performance may be obtained with electrosprayed catalyst layers employing a high Pt/C catalyst ratio.

  14. Liquid Chromatography Electrospray Ionization Mass Spectrometric (LC-ESI-MS) and Desorption Electrospray Ionization Mass Spectrometric (DESI-MS) Identification of Chemical Warfare Agents in Consumer Products

    DTIC Science & Technology

    2007-06-01

    T ACanadaY Approved for PublicR Distribution Uln& Liquid Chromatography Electrospray Ionization Mass Spectrometric ( LC -ESI- MS) and Desorption...consumer products with chemical warfare agents or other toxic chemicals. Liquid chromatography electrospray ionization mass spectrometry ( LC -ESI-MS) and...house LC -ESI-MS and LC -ESI-MS/MS methods were evaluated for the determination of chemical warfare agents in spiked bottled water samples. The

  15. Identification of Three Kinds of Citri Reticulatae Pericarpium Based on Deoxyribonucleic Acid Barcoding and High-performance Liquid Chromatography-diode Array Detection-electrospray Ionization/Mass Spectrometry/Mass Spectrometry Combined with Chemometric Analysis

    PubMed Central

    Yu, Xiaoxue; Zhang, Yafeng; Wang, Dongmei; Jiang, Lin; Xu, Xinjun

    2018-01-01

    Background: Citri Reticulatae Pericarpium is the dried mature pericarp of Citrus reticulata Blanco which can be divided into “Chenpi” and “Guangchenpi.” “Guangchenpi” is the genuine Chinese medicinal material in Xinhui, Guangdong province; based on the greatest quality and least amount, it is most expensive among others. Hesperidin is used as the marker to identify Citri Reticulatae Pericarpium described in the Chinese Pharmacopoeia 2010. However, both “Chenpi” and “Guangchenpi” contain hesperidin so that it is impossible to differentiate them by measuring hesperidin. Objective: Our study aims to develop an efficient and accurate method to separate and identify “Guangchenpi” from other Citri Reticulatae Pericarpium. Materials and Methods: The genomic deoxyribonucleic acid (DNA) of all the materials was extracted and then the internal transcribed spacer 2 was amplified, sequenced, aligned, and analyzed. The secondary structures were created in terms of the database and website established by Jörg Schultz et al. High-performance liquid chromatography-diode array detection-electrospray Ionization/mass spectrometry (HPLC-DAD-ESI-MS)/MS coupled with chemometric analysis was applied to compare the differences in chemical profiles of the three kinds of Citri Reticulatae Pericarpium. Results: A total of 22 samples were classified into three groups. The results of DNA barcoding were in accordance with principal component analysis and hierarchical cluster analysis. Eight compounds were deduced from HPLC-DAD-ESI-MS/MS. Conclusions: This method is a reliable and effective tool to differentiate the three Citri Reticulatae Pericarpium. SUMMARY The internal transcribed spacer 2 regions and the secondary structure among three kinds of Citri Reticulatae Pericarpium varied considerablyAll the 22 samples were analyzed by high-performance liquid chromatography (HPLC) to obtain the chemical profilesPrincipal component analysis and hierarchical cluster analysis were used in the chemometric analysisdeoxyribonucleic acid barcoding and HPLC-diode array detection-electrospray ionization/mass spectrometry/MS coupled with chemometric analysis provided an accurate and strong proof to identify these three herbs. Abbreviations used: CTAB: Hexadecyltrimethylammonium bromide, DNA: Deoxyribonucleic acid, ITS2: Internal transcribed spacer 2, PCR: Polymerase chain reaction. PMID:29576703

  16. Electrospray ionization of uranyl-citrate complexes

    NASA Astrophysics Data System (ADS)

    Somogyi, Árpád; Pasilis, Sofie P.; Pemberton, Jeanne E.

    2007-09-01

    Results presented here demonstrate the usefulness of electrospray ionization and gas-phase ion-molecule reactions to predict structural and electronic differences in complex inorganic ions. Electrospray ionization of uranyl citrate solutions generates positively and negatively charged ions that participate in further ion-molecule reactions in 3D ion trap and FT-ICR mass analyzers. Most ions observed are derived from the major solution uranyl-citrate complexes and involve species of {(UO2)2Cit2}2-, (UO2)3Cit2, and {(UO2)3Cit3}3-, where Cit indicates the citrate trianion, C6H5O73-. In a 3D ion trap operated at relatively high pressure, complex adducts containing solvent molecules, alkali and ammonium cations, and nitrate or chloride anions are dominant, and proton/alkali cation (Na+, K+) exchange is observed for up to six exchangeable protons in an excess of alkali cations. Adduct formation in a FT-ICR cell that is operated at lower pressures is less dominant, and direct detection of positive and negative ions of the major solution complexes is possible. Multiply charged ions are also detected, suggesting the presence of uranium in different oxidation states. Changes in uranium oxidation state are detected by He-CID and SORI-CID fragmentation, and certain fragments undergo association reactions in trapping analyzers, forming "exotic" species such as [(UO2)4O3]-, [(UO2)4O4]-, and [(UO2)4O5]-. Ion-molecule reactions with D2O in the FT-ICR cell indicate substantial differences in H/D exchange rate and D2O accommodation for different ion structures and charge states. Most notably, the positively charged ions [H2(UO2)2Cit2(H)]+ and [(UO2)2(Cit)]+ accommodate two and three D2O molecules, respectively, which reflects well the structural differences, i.e., tighter uranyl-citrate coordination in the former ion than in the latter. The corresponding negatively charged ions accommodate zero or two D2O molecules, which can be rationalized using suggested solution phase structures and charge state distributions.

  17. Fragmentation pathways and structural characterization of organophosphorus compounds related to the Chemical Weapons Convention by electron ionization and electrospray ionization tandem mass spectrometry.

    PubMed

    Hosseini, Seyed Esmaeil; Saeidian, Hamid; Amozadeh, Ali; Naseri, Mohammad Taghi; Babri, Mehran

    2016-12-30

    For unambiguous identification of Chemical Weapons Convention (CWC)-related chemicals in environmental samples, the availability of mass spectra, interpretation skills and rapid microsynthesis of suspected chemicals are essential requirements. For the first time, the electron ionization single quadrupole and electrospray ionization tandem mass spectra of a series of O-alkyl N-[bis(dimethylamino)methylidene]-P-methylphosphonamidates (Scheme 1, cpd 4) were studied for CWC verification purposes. O-Alkyl N-[bis(dimethylamino)methylidene]-P-methylphosphonamidates were prepared through a microsynthetic method and were analyzed using electron ionization and electrospray ionization mass spectrometry with gas and liquid chromatography, respectively, as MS-inlet systems. General EI and ESI fragmentation pathways were proposed and discussed, and collision-induced dissociation studies of the protonated derivatives of these compounds were performed to confirm proposed fragment ion structures by analyzing mass spectra of deuterated analogs. Mass spectrometric studies revealed some interesting fragmentation pathways during the ionization process, such as McLafferty rearrangement, hydrogen rearrangement and a previously unknown intramolecular electrophilic aromatic substitution reaction. The EI and ESI fragmentation routes of the synthesized compounds 4 were investigated with the aim of detecting and identifying CWC-related chemicals during on-site inspection and/or off-site analysis and toxic chemical destruction monitoring. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Simultaneous quantification of 25 active constituents in the total flavonoids extract from Herba Desmodii Styracifolii by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry.

    PubMed

    Guo, Panpan; Yan, Wenying; Han, Qingjie; Wang, Chunying; Zhang, Zijian

    2015-04-01

    A sensitive and selective high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry method has been developed and validated for the simultaneous determination of 25 active constituents, including 21 flavonoids and four phenolic acids in the total flavonoids extract from Herba Desmodii Styracifolii for the first time. Among the 25 compounds, seven compounds including caffeic acid, acacetin, genistein, genistin, diosmetin, diosmin and hesperidin were identified and quantified for the first time in Herba Desmodii Styracifolii. Chromatographic separation was accomplished on a ZORBAX SB-C18 (250 mm×4.6 mm, 5.0 μm) column using gradient elution of methanol and 0.1‰ acetic acid v/v at a flow rate of 1.0 mL/min. The identification and quantification of the analytes were achieved using negative electrospray ionization mass spectrometry in multiple-reaction monitoring mode. The method was fully validated in terms of limits of detection and quantification, linearity, precision and accuracy. The results indicated that the developed method is simple, rapid, specific and reliable. Furthermore, the developed method was successfully applied to quantify the 25 active components in six batches of total flavonoids extract from Herba Desmodii Styracifolii. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Derivatization of Dextran for Multiply Charged Ion Formation and Electrospray Ionization Time-of-Flight Mass Spectrometric Analysis

    NASA Astrophysics Data System (ADS)

    Tapia, Jesus B.; Hibbard, Hailey A. J.; Reynolds, Melissa M.

    2017-10-01

    We present the use of a simple, one-pot derivatization to allow the polysaccharide dextran to carry multiple positive charges, shifting its molecular weight distribution to a lower m/ z range. We performed this derivatization because molecular weight measurements of polysaccharides by mass spectrometry are challenging because of their lack of readily ionizable groups. The absence of ionizable groups limits proton abstraction and suppresses proton adduction during the ionization process, producing mass spectra with predominantly singly charged metal adduct ions, thereby limiting the detection of large polysaccharides. To address this challenge, we derivatized dextran T1 (approximately 1 kDa) by attaching ethylenediamine, giving dextran readily ionizable, terminal amine functional groups. The attached ethylenediamine groups facilitated proton adduction during the ionization process in positive ion mode. Using the low molecular weight dextran T1, we tracked the number of ethylenediamine attachments by measuring the mass shift from underivatized to derivatized dextran T1. Using electrospray ionization time-of-flight mass spectrometry, we observed derivatized dextran chains ranging from two to nine glucose residues with between one and four attachments/charges. Our success in shifting derivatized dextran T1 toward the low m/ z range suggests potential for this derivatization as a viable route for analysis of high molecular weight polysaccharides using electrospray ionization time-of-flight mass spectrometry. [Figure not available: see fulltext.

  20. Simultaneous Quantification of 11 Constituents in Wuji Pill Using Ultra Performance Liquid Chromatography Coupled With a Triple Quadrupole Electrospray Tandem Mass Spectrometry.

    PubMed

    Tian, Tingting; Jin, Yiran; Ma, Yinghua; Xie, Weiwei; Xu, Huijun; Du, Yingfeng

    2016-02-01

    An ultra performance liquid chromatography coupled with a triple quadrupole electrospray tandem mass spectrometry (UPLC-MS-MS) method was developed for analyzing and identifying the constituents of 11 compounds including berberine, epiberberine, berberrubine, jatrorrhizine, coptisine, palmatine, evodiamine, rutaecarpine, limonin, paeoniflorin and albiflorin in Wuji pill (WJ pill), a traditional Chinese medicine. The chromatographic separation was performed on a C18 column and the mobile phase was composed of water (0.1% formic acid and 2 mmol ammonium acetate) and methanol with a linear gradient elution. The detection was performed by multiple reaction monitoring mode, using electrospray ionization in the positive ion mode. The total run time was 14 min. The calibration curves were linear with all correlation coefficients higher than 0.9987 in the tested range. The intra- and interday precisions were no more than 4.9%, and the average recoveries were from 92.4 to 107.8% with the relative standard deviations no more than 7.8%. The developed method was successfully employed to analyze five batches of WJ pill samples. This is the first time to establish a method for the quality control of WJ pill to ensure the safety and efficacy in clinical applications effectively. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Comparison of PCR-Electrospray Ionization Mass Spectrometry with 16S rRNA PCR and Amplicon Sequencing for Detection of Bacteria in Excised Heart Valves

    PubMed Central

    Peeters, Bart; Herijgers, Paul; Beuselinck, Kurt; Peetermans, Willy E.; Herregods, Marie-Christin

    2016-01-01

    Identification of the causative pathogen of infective endocarditis (IE) is crucial for adequate management and therapy. A broad-range PCR-electrospray ionization mass spectrometry (PCR-ESI-MS) technique was compared with broad-spectrum 16S rRNA PCR and amplicon sequencing (16S rRNA PCR) for the detection of bacterial pathogens in 40 heart valves obtained from 34 definite infective endocarditis patients according to the modified Duke criteria and six nonendocarditis patients. Concordance between the two molecular techniques was 98% for being positive or negative, 97% for concordant identification up to the genus level, and 77% for concordant identification up to the species level. Sensitivity for detecting the causative pathogen (up to the genus level) in excised heart valves was 88% for 16S rRNA PCR and 85% for PCR-ESI-MS; the specificity was 83% for both methods. The two molecular techniques were significantly more sensitive than valve culture (18%) and accurately identified bacteria in excised heart valves. In eight patients with culture-negative IE, the following results were obtained: concordant detection of Coxiella burnetii (n = 2), Streptococcus gallolyticus (n = 1), Propionibacterium acnes (n = 1), and viridans group streptococci (n = 1) by both molecular tests, detection of P. acnes by PCR-ESI-MS whereas the 16S rRNA PCR was negative (n = 1), and a false-negative result by both molecular techniques (n = 2). In one case of IE caused by viridans streptococci, PCR-ESI-MS was positive for Enterococcus spp. The advantages of PCR-ESI-MS compared to 16S rRNA PCR are its automated workflow and shorter turnaround times. PMID:27629895

  2. Broad-Range PCR Coupled with Electrospray Ionization Time of Flight Mass Spectrometry for Detection of Bacteremia and Fungemia in Patients with Neutropenic Fever

    PubMed Central

    Maertens, J.; Bueselinck, K.; Lagrou, K.

    2016-01-01

    Infection is an important complication in patients with hematologic malignancies or solid tumors undergoing intensive cytotoxic chemotherapy. In only 20 to 30% of the febrile neutropenic episodes, an infectious agent is detected by conventional cultures. In this prospective study, the performance of broad-range PCR coupled with electrospray ionization time of flight mass spectrometry (PCR/ESI-MS) technology was compared to conventional blood cultures (BC) in a consecutive series of samples from high-risk hematology patients. In 74 patients, BC and a whole-blood sample for PCR/ESI-MS (Iridica BAC BSI; Abbott, Carlsbad, CA, USA) were collected at the start of each febrile neutropenic episode and, in case of persistent fever, also at day 5. During 100 different febrile episodes, 105 blood samples were collected and analyzed by PCR/ESI-MS. There was evidence of a bloodstream infection (BSI) in 36/105 cases (34%), based on 14 cases with both PCR/ESI-MS and BC positivity, 17 cases with BC positivity only, and 5 cases with PCR/ESI-MS positivity only. The sensitivity of PCR/ESI-MS was 45%, specificity was 93%, and the negative predictive value was 80% compared to blood culture. PCR/ESI-MS detected definite pathogens (Fusobacterium nucleatum and Streptococcus pneumoniae) missed by BC, whereas it missed both Gram-negative and Gram-positive organisms detected by BC. PCR/ESI-MS testing detected additional microorganisms but showed a low sensitivity (45%) compared to BC in neutropenic patients. Our results indicate a lower concordance between BC and PCR/ESI-MS in the neutropenic population than what has been previously reported in other patient groups with normal white blood cell distribution, and a lower sensitivity than other PCR-based methods. PMID:27440820

  3. A FOURTH H I 21 cm ABSORPTION SYSTEM IN THE SIGHT LINE OF MG J0414+0534: A RECORD FOR INTERVENING ABSORBERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanna, A.; Webb, J. K.; Curran, S. J.

    2013-08-01

    We report the detection of a strong H I 21 cm absorption system at z = 0.5344, as well as a candidate system at z = 0.3389, in the sight line toward the z = 2.64 quasar MG J0414+0534. This, in addition to the absorption at the host redshift and the other two intervening absorbers, takes the total to four (possibly five). The previous maximum number of 21 cm absorbers detected along a single sight line is two and so we suspect that this number of gas-rich absorbers is in some way related to the very red color of themore » background source. Despite this, no molecular gas (through OH absorption) has yet been detected at any of the 21 cm redshifts, although, from the population of 21 cm absorbers as a whole, there is evidence for a weak correlation between the atomic line strength and the optical-near-infrared color. In either case, the fact that so many gas-rich galaxies (likely to be damped Ly{alpha} absorption systems) have been found along a single sight line toward a highly obscured source may have far-reaching implications for the population of faint galaxies not detected in optical surveys, a possibility which could be addressed through future wide-field absorption line surveys with the Square Kilometer Array.« less

  4. Capillary moving-boundary isotachophoresis with electrospray ionization mass-spectrometric detection and hydrogen ion used as essential terminator: Methodology for sensitive analysis of hydroxyderivatives of s-triazine herbicides in waters.

    PubMed

    Malá, Zdena; Gebauer, Petr

    2017-10-06

    Capillary isotachophoresis (ITP) is an electrophoretic technique offering high sensitivity due to permanent stacking of the migrating analytes. Its combination with electrospray-ionization mass-spectrometric (ESI-MS) detection is limited by the narrow spectrum of ESI-compatible components but can be compensated by experienced system architecture. This work describes a methodology for sensitive analysis of hydroxyderivatives of s-triazine herbicides, based on implementation of the concepts of moving-boundary isotachophoresis and of H + as essential terminating component into cationic ITP with ESI-MS detection. Theoretical description of such kind of system is given and equations for zone-related boundary mobilities are derived, resulting in a much more general definition of the effective mobility of the terminating H + zone than used so far. Explicit equations allowing direct calculation for selected simple systems are derived. The presented theory allows prediction of stacking properties of particular systems and easy selection of suitable electrolyte setups. A simple ESI-compatible system composed of acetic acid and ammonium with H + and ammonium as a mixed terminator was selected for the analysis of 2-hydroxyatrazine and 2-hydroxyterbutylazine, degradation products of s-triazine herbicides. The proposed method was tested with direct injection without any sample pretreatment and provided excellent linearity and high sensitivity with limits of detection below 100ng/L (0.5nM). Example analyses of unspiked and spiked drinking and river water are shown. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Secondary electrospray ionization-ion mobility spectrometry for explosive vapor detection.

    PubMed

    Tam, Maggie; Hill, Herbert H

    2004-05-15

    The unique capability of secondary electrospray ionization (SESI) as a nonradioactive ionization source to detect analytes in both liquid and gaseous samples was evaluated using aqueous solutions of three common military explosives: cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), nitroglycerin (NG) and pentaerythritol tetranitrate (PETN). The adducts formed between the compounds and their respective dissociation product, RDX.NO(2)(-), NG.NO(3)(-), and PETN.NO(3)(-), gave the most intense signal for the individual compound but were more sensitive to temperature than other species. These autoadducts were identified as RDX.NO(2)(-), NG.NO(3)(-), and PETN.NO(3)(-) and had maximum signal intensity at 137, 100, and 125 degrees C, respectively. The reduced mobility values of the three compounds were constant over the temperature range from 75 to 225 degrees C. The signal-to-noise ratios for RDX, NG, and PETN at 50 mg L(-1) in methanol-water were 340, 270, and 170, respectively, with a nominal noise of 8 +/- 2 pA. In addition to the investigation of autoadduct formation, the concept of doping the ionization source with nonvolatile adduct-forming agents was investigated and described for the first time. The SESI-IMS detection limit for RDX was 116 microg L(-1) in the presence of a traditional volatile chloride dopant and 5.30 microg L(-1) in the presence of a nonvolatile nitrate dopant. In addition to a lower detection limit, the nitrate dopant also produced a greater response sensitivity and a higher limit of linearity than did the traditional volatile chloride dopant.

  6. Characterization, stoichiometry, and stability of salivary protein-tannin complexes by ESI-MS and ESI-MS/MS.

    PubMed

    Canon, Francis; Paté, Franck; Meudec, Emmanuelle; Marlin, Thérèse; Cheynier, Véronique; Giuliani, Alexandre; Sarni-Manchado, Pascale

    2009-12-01

    Numerous protein-polyphenol interactions occur in biological and food domains particularly involving proline-rich proteins, which are representative of the intrinsically unstructured protein group (IUP). Noncovalent protein-ligand complexes are readily detected by electrospray ionization mass spectrometry (ESI-MS), which also gives access to ligand binding stoichiometry. Surprisingly, the study of interactions between polyphenolic molecules and proteins is still an area where ESI-MS has poorly benefited, whereas it has been extensively applied to the detection of noncovalent complexes. Electrospray ionization mass spectrometry has been applied to the detection and the characterization of the complexes formed between tannins and a human salivary proline-rich protein (PRP), namely IB5. The study of the complex stability was achieved by low-energy collision-induced dissociation (CID) measurements, which are commonly implemented using triple quadrupole, hybrid quadrupole time-of-flight, or ion trap instruments. Complexes composed of IB5 bound to a model polyphenol EgCG have been detected by ESI-MS and further analyzed by MS/MS. Mild ESI interface conditions allowed us to observe intact noncovalent PRP-tannin complexes with stoichiometries ranging from 1:1 to 1:5. Thus, ESI-MS shows its efficiency for (1) the study of PRP-tannin interactions, (2) the determination of stoichiometry, and (3) the study of complex stability. We were able to establish unambiguously both their stoichiometries and their overall subunit architecture via tandem mass spectrometry and solution disruption experiments. Our results prove that IB5.EgCG complexes are maintained intact in the gas phase.

  7. Positive and negative electrospray LC-MS-MS methods for quantitation of the antiparasitic endectocide drugs, abamectin, doramectin, emamectin, eprinomectin, ivermectin, moxidectin and selamectin in milk.

    PubMed

    Durden, David A

    2007-05-01

    Avermectin endectocides are used for the treatment of cattle against a variety of nematode and arthropod parasites, and consequently may appear in milk after normal or off-label use. The compounds abamectin, doramectin, and ivermectin, contain only C, H and O and may be expected to be detected by LC-MS in negative ion mode. The others contain nitrogen in addition and would be expected to be preferentially ionized in positive mode. The use of positive ion and negative ion methods with electrospray LC-MS-MS were compared. Using negative ion the compounds abamectin, doramectin, ivermectin, emamectin, eprinomectin, and moxidectin gave a curvilinear response and were quantified in raw milk by LC-MS-MS with a triethylamine-acetonitrile buffer over the concentration range 1-60 ppb (microg/kg) using selamectin as the internal standard. The limits of detection (LOD) were between 0.19 ppb (doramectin) and 0.38 ppb (emamectin). The compounds gave maximum sensitivity with positive ionisation from a formic acid-ammonium formate-acetonitrile buffer and were detected in milk (LC-MS-MS) also with a curvilinear response over the range 0.5-60 ppb. Although the positive ion signals were larger, with somewhat lower limits of detection (LOD between 0.06 ppb (doramectin) and 0.32 ppb (moxidectin) the negative ion procedure gave a more linear response and more consistent results. Comparison of spiked samples in the range 2-50 ppb showed a high degree of correlation between the two methods.

  8. Extractive electrospray ionization mass spectrometry toward in situ analysis without sample pretreatment.

    PubMed

    Li, Ming; Hu, Bin; Li, Jianqiang; Chen, Rong; Zhang, Xie; Chen, Huanwen

    2009-09-15

    A homemade novel nanoextractive electrospray ionization (nanoEESI) source has been characterized for in situ mass spectrometric analysis of ambient samples without sample pretreatment. The primary ions generated using a nanospray emitter interact with the neutral sample plume created by manually nebulizing liquid samples, allowing production of the analyte ions in the spatial cross section of the nanoEESI source. The performance of nanoEESI is experimentally investigated by coupling the nanoEESI source to a commercial LTQ mass spectrometer for rapid analysis of various ambient samples using positive/negative ion detection modes. Compounds of interest in actual samples such as aerosol drug preparations, beverages, milk suspensions, farmland water, and groundwater were unambiguously detected using tandem nanoEESI ion trap mass spectrometry. The limit of detection was low picogram per milliliter levels for the compounds tested. Acceptable relative standard deviation (RSD) values (5-10%) were obtained for direct measurement of analytes in complex matrixes, providing linear dynamic signal responses using manual sample introduction. A single sample analysis was completed within 1.2 s. Requiring no sheath gas for either primary ion production or neutral sample introduction, the nanoEESI has advantages including readiness for miniaturization and integration, simple maintenance, easy operation, and low cost. The experimental data demonstrate that the nanoEESI is a promising tool for high-throughput, sensitive, quantitative, in situ analysis of ambient complex samples, showing potential applications for in situ analysis in multiple disciplines including but not limited to pharmaceutical analysis, food quality control, pesticides residue detection, and homeland security.

  9. Photoacoustic-guided ultrasound therapy with a dual-mode ultrasound array

    NASA Astrophysics Data System (ADS)

    Prost, Amaury; Funke, Arik; Tanter, Mickaël; Aubry, Jean-François; Bossy, Emmanuel

    2012-06-01

    Photoacoustics has recently been proposed as a potential method to guide and/or monitor therapy based on high-intensity focused ultrasound (HIFU). We experimentally demonstrate the creation of a HIFU lesion at the location of an optical absorber, by use of photoacoustic signals emitted by the absorber detected on a dual mode transducer array. To do so, a dedicated ultrasound array intended to both detect photoacoustic waves and emit HIFU with the same elements was used. Such a dual-mode array provides automatically coregistered reference frames for photoacoustic detection and HIFU emission, a highly desired feature for methods involving guidance or monitoring of HIFU by use of photoacoustics. The prototype is first characterized in terms of both photoacoustic and HIFU performances. The probe is then used to perform an idealized scenario of photoacoustic-guided therapy, where photoacoustic signals generated by an absorbing thread embedded in a piece of chicken breast are used to automatically refocus a HIFU beam with a time-reversal mirror and necrose the tissue at the location of the absorber.

  10. Composition for detecting uranyl

    DOEpatents

    Baylor, Lewis C.; Stephens, Susan M.

    1995-01-01

    A composition for detecting the presence and concentration of a substance such as uranyl, comprising an organohalide covalently bonded to an indicator for said substance. The composition has at least one active OH site for forming a complex with the substance to be detected. The composition is made by reacting equimolar amounts of the indicator and the organohalide in a polar organic solvent. The absorbance spectrum of the composition-uranyl complex is shifted with respect to the absorbance spectrum of the indicator-uranyl complex, to provide better spectral resolution for detecting uranyl.

  11. Direct analysis of triterpenes from high-salt fermented cucumbers using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI)

    USDA-ARS?s Scientific Manuscript database

    High-salt samples present a challenge to mass spectrometry (MS) analysis, particularly when electrospray ionization (ESI) is used, requiring extensive sample preparation steps such as desalting, extraction, and purification. In this study, infrared matrix-assisted laser desorption electrospray ioniz...

  12. Electrospray neutralization process and apparatus for generation of nano-aerosol and nano-structured materials

    DOEpatents

    Bailey, Charles L.; Morozov, Victor; Vsevolodov, Nikolai N.

    2010-08-17

    The claimed invention describes methods and apparatuses for manufacturing nano-aerosols and nano-structured materials based on the neutralization of charged electrosprayed products with oppositely charged electrosprayed products. Electrosprayed products include molecular ions, nano-clusters and nano-fibers. Nano-aerosols can be generated when neutralization occurs in the gas phase. Neutralization of electrospan nano-fibers with molecular ions and charged nano-clusters may result in the formation of fibrous aerosols or free nano-mats. Nano-mats can also be produced on a suitable substrate, forming efficient nano-filters.

  13. Water-assisted femtosecond laser machining of electrospray nozzles on glass microfluidic devices.

    PubMed

    An, Ran; Hoffman, Michelle D; Donoghue, Margaret A; Hunt, Alan J; Jacobson, Stephen C

    2008-09-15

    Using water-assisted femtosecond laser machining, we fabricated electrospray nozzles on glass coverslips and on assembled microfluidic devices. Machining the nozzles after device assembly facilitated alignment of the nozzles over the microchannels. The basic nozzle design is a through-hole in the coverslip to pass liquids and a trough machined around the through-hole to confine the electrospray and prevent liquid from wicking across the glass surface. Electrospray from the nozzles was stable with and without pressure-driven flow applied and was evaluated using mass spectra of the peptide bradykinin.

  14. Secondary electrospray ionization of complex vapor mixtures. Theoretical and experimental approach.

    PubMed

    Vidal-de-Miguel, Guillermo; Herrero, Ana

    2012-06-01

    In secondary electrospray ionization (SESI) systems, gaseous analytes exposed to an electrospray plume become ionized after charge is transferred from the charging electrosprayed particles (the charging agent) to the vapor species. Currently available SESI models are valid for simplified systems having only one type of electrosprayed species, which ionizes only one single vapor species, and for the limit of low vapor concentration. More realistic models require considering other effects. Here we develop a theoretical model that accounts for the effects of high vapor concentration, saturation effects, interferences between different vapor species, and electrosprays producing different types of species from the liquid phase. In spite of the relatively high complexity of the problem, we find simple relations between the different ionic species concentrations that hold independently of the particular ion source configuration. Our model suggests that an ideal SESI system should use highly concentrated charging agents composed preferably of only one dominating species with low mobility. Experimental measurements with a MeOH-H(2)O-NH(3) electrospray and a mixture of fatty acids and lactic acid served to test the theory, which gives good qualitative results. These results also suggest that the SESI ionization mechanism is primarily based on ions rather than on charged droplets.

  15. Evanescent wave absorbance based fiber optic biosensor for label-free detection of E. coli at 280 nm wavelength.

    PubMed

    Bharadwaj, Reshma; Sai, V V R; Thakare, Kamini; Dhawangale, Arvind; Kundu, Tapanendu; Titus, Susan; Verma, Pradeep Kumar; Mukherji, Soumyo

    2011-03-15

    A novel label-free technique for the detection of pathogens based on evanescent wave absorbance (EWA) changes at 280 nm from a U-bent optical fiber sensor is demonstrated. Bending a decladded fiber into a U-shaped structure enhances the penetration depth of evanescent waves and hence sensitivity of the probe. We show that the enhanced EWA response from such U-bent probes, caused by the inherent optical absorbance properties of bacterial cells or biomolecules specifically bound to the sensor surface, can be exploited for the detection of pathogens. A portable optical set-up with a UV light emitting diode, a spectrometer and U-bent fiber optic probe of 200 μm core diameter, 0.75 mm bend radius and effective probe length of 1cm demonstrated an ability to detect less than 1000 cfu/ml. Copyright © 2011. Published by Elsevier B.V.

  16. Method for outlier detection: a tool to assess the consistency between laboratory data and ultraviolet-visible absorbance spectra in wastewater samples.

    PubMed

    Zamora, D; Torres, A

    2014-01-01

    Reliable estimations of the evolution of water quality parameters by using in situ technologies make it possible to follow the operation of a wastewater treatment plant (WWTP), as well as improving the understanding and control of the operation, especially in the detection of disturbances. However, ultraviolet (UV)-Vis sensors have to be calibrated by means of a local fingerprint laboratory reference concentration-value data-set. The detection of outliers in these data-sets is therefore important. This paper presents a method for detecting outliers in UV-Vis absorbances coupled to water quality reference laboratory concentrations for samples used for calibration purposes. Application to samples from the influent of the San Fernando WWTP (Medellín, Colombia) is shown. After the removal of outliers, improvements in the predictability of the influent concentrations using absorbance spectra were found.

  17. Novel quad-band terahertz metamaterial absorber based on single pattern U-shaped resonator

    NASA Astrophysics Data System (ADS)

    Wang, Ben-Xin; Wang, Gui-Zhen

    2017-03-01

    A novel quad-band terahertz metamaterial absorber using four different modes of single pattern resonator is demonstrated. Four obvious frequencies with near-perfect absorption are realized. Near-field distributions of the four modes are provided to reveal the physical picture of the multiple-band absorption. Unlike most previous quad-band absorbers that typically require four or more patterns, the designed absorber has only one resonant structure, which is simpler than previous works. The presented quad-band absorber has potential applications in biological sensing, medical imaging, and material detection.

  18. Evaluation of inhaled and cutaneous doses of imidacloprid during stapling ornamental plants in tunnels or greenhouses.

    PubMed

    Aprea, Cristina; Lunghini, Liana; Banchi, Bruno; Peruzzi, Antonio; Centi, Letizia; Coppi, Luana; Bogi, Mirella; Marianelli, Enrico; Fantacci, Mariella; Catalano, Pietro; Benvenuti, Alessandra; Miligi, Lucia; Sciarra, Gianfranco

    2009-09-01

    The aim of this research was to assess dermal and respiratory exposure of workers to imidacloprid during manual operations with ornamental plants previously treated in greenhouses or tunnels. A total of 10 female workers, 5 in greenhouses and 5 in tunnels, were monitored for 3 or 5 consecutive days. Actual skin contamination, excluding hands, was evaluated using nine filter paper pads placed directly on the skin. To evaluate the efficacy of protective clothing in reducing occupational exposure we also placed four pads on top of the outer clothing. Hand contamination was evaluated by washing with 95% ethanol. Respiratory exposure was evaluated by personal air sampling. Respiratory dose was calculated on the basis of a lung ventilation of 15 l/min. Absorbed doses were calculated assuming a skin penetration of 10% and a respiratory retention of 100%. Dislodgeable foliar residues (DFRs) were determined during the days of re-entry in order to determine the dermal transfer factor. From the dependence of dermal exposure of hands from DFRs, a mean transfer factor was estimated to be 36.4 cm(2)/h. Imidacloprid was determined by liquid chromatography with selective mass detection and electrospray interface in all matrices analysed. Respiratory dose was 4.1+/-4.0 (0.1-14.3)% and 3.0+/-2.0 (0.6-6.9)% (mean+/-SD (range)) of the total real dose during work in tunnels and greenhouses, respectively. The estimated absorbed doses, 0.29+/-0.45 microg/kg (0.06-2.25 microg/kg) body weight and 0.32+/-0.18 microg/kg (0.07-0.66 microg/kg) body weight (mean+/-SD (range)) in tunnels and in greenhouses, respectively, were less than the acceptable operator exposure level of 0.15 mg/kg body weight and than the acceptable daily intake of 0.05 mg/kg body weight. The hands and exposed skin of all workers were found to be contaminated, indicating that greater precautions, such as daily changing of gloves and clothing, are necessary to reduce skin exposure.

  19. Research on Glass Frit Deposition Based on the Electrospray Process

    PubMed Central

    Liu, Yifang; Chen, Daner; Zhan, Zhan; Li, Chenlei; Zheng, Jianyi; Sun, Daoheng

    2016-01-01

    In this paper, the electrospray technology is used to easily deposit the glass frit into patterns at a micro-scale level. First, far-field electrospray process was carried out with a mixture of glass frit in the presence of ethanol. A uniform, smooth, and dense glass frit film was obtained, verifying that the electrospray technology was feasible. Then, the distance between the nozzle and the substrate was reduced to 2 mm to carry out near-field electrospray. The experimental process was improved by setting the range of the feed rate of the substrate to match both the concentration and the flow rate of the solution. Spray diameter could be less at the voltage of 2 kV, in which the glass frit film was expected to reach the minimum line width. A uniform glass frit film with a line width within the range of 400–500 μm was prepared when the speed of the substrate was 25 mm/s. It indicates that electrospray is an efficient technique for the patterned deposition of glass frit in wafer-level hermetic encapsulation. PMID:28773417

  20. Determination of drug residues in urine of dogs receiving anti-cancer chemotherapy by liquid chromatography-electrospray ionization- tandem mass spectrometry: is there an environmental or occupational risk?

    PubMed

    Hamscher, Gerd; Mohring, Siegrun A I; Knobloch, Anna; Eberle, Nina; Nau, Heinz; Nolte, Ingo; Simon, Daniela

    2010-04-01

    Cytotoxic drugs, previously used only in human medicine, are increasingly utilized for cancer treatment in veterinary practice. We developed and validated a liquid chromatography (LC)-electrospray ionization-tandem mass spectrometry (MS-MS) method to determine vincristine, vinblastine, cyclophosphamide, and doxorubicin in canine urine. Sample pretreatment consisted of liquid-liquid extraction, and LC separation was carried out on an RP C(18) column employing a 0.5% formic acid/methanol gradient system. The analytes were detected in positive ion mode using the MS-MS scan mode. The mean recoveries in six different urine samples were between 64.2% and 86.9%. Limits of quantitation were 0.5 microg/L for vincristine and vinblastine, 1 microg/L for cyclophosphamide, and 5 microg/L for doxorubicin; limits of detection were approximately 0.25 microg/L for vincristine, vinblastine, and cyclophosphamide and 0.5 microg/L for doxorubicin. It could be demonstrated that all investigated drugs are found in urine of dogs undergoing chemotherapy. In samples from day 1 after chemotherapy, as much as 63 microg/L vincristine, 111 microg/L vinblastine, and 762 microg/L doxorubicin could be detected. Cyclophosphamide showed only minor concentrations on day 1, but up to 2583 microg/L could be found directly after chemotherapy. These initial data show that there might be a potential contamination risk when administering cytotoxics in veterinary medicine.

  1. High-performance liquid chromatography-diode array and electrospray-mass spectrometry analysis of non-allowed substances in cosmetic products for preventing hair loss and other hormone-dependent skin diseases.

    PubMed

    De Orsi, Daniela; Pellegrini, Manuela; Pichini, Simona; Mattioli, Donatella; Marchei, Emilia; Gagliardi, Luigi

    2008-11-04

    A simple high-performance liquid chromatography (HPLC) method with ultraviolet diode array (UV-DAD) and electrospray ionisation mass spectrometry (ESI-MS) detection has been developed for the determination of minoxidil, progesterone, estrone, spironolactone, canrenone, hydrocortisone and triamcinolone acetonide in cosmetic products. The presence of these substances in commercial cosmetic samples is prohibited. The compounds were separated by reversed phase chromatography with water (0.1% trifluoroacetic acid) and acetonitrile gradient elution and detected by UV-DAD at 230, 254 and 280 nm and by ESI-MS positive ionisation mode. Benzoic acid was used as internal standard. Linearity was studied with UV-DAD detection from 1.50 to 1,000 microg/ml or mug/g range, depending on the different compounds and type of cosmetic preparation and with ESI-MS in the 50-1,000 ng/ml or ng/g range. Good determination coefficients (r(2)>or=0.99) were found in both UV and ESI-MS. At three concentrations spanning the linear dynamic ranges of both UV-DAD and ESI-MS assay, mean recoveries were always higher than 90% for the different analytes. This method was successfully applied to the analysis of substances under investigations illegally added in cosmetic cream and lotions, sold on internet web sites to prevent hair loss and other hormone-dependent skin diseases, like acne and hirsutism.

  2. High-performance liquid chromatography-diode array detection-electrospray ionization multi-stage mass spectrometric screening of an insect/plant system: the case of Spodoptera littoralis/Lycopersicon esculentum phenolics and alkaloids.

    PubMed

    Ferreres, Federico; Taveira, Marcos; Gil-Izquierdo, Angel; Oliveira, Luísa; Teixeira, Tânia; Valentão, Patrícia; Simões, Nelson; Andrade, Paula B

    2011-07-30

    High-performance liquid chromatography-diode array detection-electrospray ionization multi-stage mass spectrometry (HPLC-DAD-ESI-MS(n)) is considered to be a very valuable tool for the characterization of compounds found in trace amounts in natural matrices, as their previous isolation and clean-up steps can be avoided. Micro-scale separation increases the potential of this analytical technique, allowing the determination of compounds in reduced samples. Spodoptera littoralis represents a major challenge to Solanaceae plants, as it is one of the most deleterious pests. The S. littoralis/Lycopersicon esculentum system was studied for the first time concerning glycoalkaloids and phenolics. Using HPLC-DAD-ESI-MS(n) we were able to characterize 15 phenolic compounds in L. esculentum leaves. Nine of them are reported for the first time. Some differences were found between leaves of cerasiforme and 'Bull's heart' varieties. However, in the materials of S. littoralis (larvae, adults, exuviae and excrements) reared in both L. esculentum leaves no phenolics were identified. α-Tomatine was the main glycoalkaloid in the host plant. The glycoalkaloid composition of the different S. littoralis materials was distinct, with α-tomatine and dehydrotomatine being the main detected compounds in larvae and excrements. These results add knowledge to the ecological interaction in this insect/plant duo, for which it is hard to obtain considerable sample amounts. Copyright © 2011 John Wiley & Sons, Ltd.

  3. Extra virgin (EV) and ordinary (ON) olive oils: distinction and detection of adulteration (EV with ON) as determined by direct infusion electrospray ionization mass spectrometry and chemometric approaches.

    PubMed

    Alves, Júnia de O; Neto, Waldomiro B; Mitsutake, Hery; Alves, Paulo S P; Augusti, Rodinei

    2010-07-15

    Extra virgin (EV), the finest and most expensive among all the olive oil grades, is often adulterated by the cheapest and lowest quality ordinary (ON) olive oil. A new methodology is described herein that provides a simple, rapid, and accurate way not only to detect such type of adulteration, but also to distinguish between these olive oil grades (EV and ON). This approach is based on the application of direct infusion electrospray ionization mass spectrometry in the positive ion mode, ESI(+)-MS, followed by the treatment of the MS data via exploratory statistical approaches, PCA (principal component analysis) and HCA (hierarchical clustering analysis). Ten distinct brands of each EV and ON olive oil, acquired at local stores, were analyzed by ESI(+)-MS and the results from HCA and PCA clearly indicated the formation of two distinct groups related to these two categories. For the adulteration study, one brand of each olive oil grade (EV and ON) was selected. The counterfeit samples (a total of 20) were then prepared by adding assorted proportions, from 1 to 20% w/w, with increments of 1% w/w, of the ON to the EV olive oil. The PCA and HCA methodologies, applied to the ESI(+)-MS data from the counterfeit (20) and authentic (10) EV samples, were able to readily detect adulteration, even at levels as low as 1% w/w. Copyright 2010 John Wiley & Sons, Ltd.

  4. Design, Modeling, Fabrication, and Evaluation of the Air Amplifier for Improved Detection of Biomolecules by Electrospray Ionization Mass Spectrometry

    PubMed Central

    Robichaud, Guillaume; Dixon, R. Brent; Potturi, Amarnatha S.; Cassidy, Dan; Edwards, Jack R.; Sohn, Alex; Dow, Thomas A.; Muddiman, David C.

    2010-01-01

    Through a multi-disciplinary approach, the air amplifier is being evolved as a highly engineered device to improve detection limits of biomolecules when using electrospray ionization. Several key aspects have driven the modifications to the device through experimentation and simulations. We have developed a computer simulation that accurately portrays actual conditions and the results from these simulations are corroborated by the experimental data. These computer simulations can be used to predict outcomes from future designs resulting in a design process that is efficient in terms of financial cost and time. We have fabricated a new device with annular gap control over a range of 50 to 70 μm using piezoelectric actuators. This has enabled us to obtain better aerodynamic performance when compared to the previous design (2× more vacuum) and also more reproducible results. This is allowing us to study a broader experimental space than the previous design which is critical in guiding future directions. This work also presents and explains the principles behind a fractional factorial design of experiments methodology for testing a large number of experimental parameters in an orderly and efficient manner to understand and optimize the critical parameters that lead to obtain improved detection limits while minimizing the number of experiments performed. Preliminary results showed that several folds of improvements could be obtained for certain condition of operations (up to 34 folds). PMID:21499524

  5. Capillary zone electrophoresis for analysis of complex proteomes using an electrokinetically pumped sheath flow nanospray interface

    PubMed Central

    Sun, Liangliang; Zhu, Guijie; Yan, Xiaojing; Champion, Mathew M.

    2014-01-01

    The vast majority of proteomic studies employ reversed-phase high-performance liquid chromatography coupled with tandem mass spectrometry for analysis of the tryptic digest of a cellular lysate. This technology is quite mature, and typically provides identification of hundreds to thousands of peptides, which is used to infer the identity of hundreds to thousands of proteins. These approaches usually require milligrams to micrograms of starting material. Capillary zone electrophoresis provides an interesting alternative separation method based on a different separation mechanism than HPLC. Capillary electrophoresis received some attention for protein analysis beginning 25 years ago. Those efforts stalled because of the limited performance of the electrospray interfaces and the limited speed and sensitivity of mass spectrometers of that era. This review considers a new electrospray interface design coupled with Orbitrap Velos and linear Q-trap mass spectrometers. Capillary zone electrophoresis coupled with this interface and these detectors provides single shot detection of >1,250 peptides from an E. coli digest in less than one hour, identification of nearly 5,000 peptides from analysis of seven fractions produced by solid-phase extraction of the E. coli digest in a six hour total analysis time, low attomole detection limits for peptides generated from standard proteins, and high zeptomole detection limits for selected ion monitoring of peptides. Incorporation of an integrated on-line immobilized trypsin microreactor allows digestion and analysis of picogram amounts of a complex eukaryotic proteome. PMID:24277677

  6. Quantitative detection of nitric oxide in exhaled human breath by extractive electrospray ionization mass spectrometry

    NASA Astrophysics Data System (ADS)

    Pan, Susu; Tian, Yong; Li, Ming; Zhao, Jiuyan; Zhu, Lanlan; Zhang, Wei; Gu, Haiwei; Wang, Haidong; Shi, Jianbo; Fang, Xiang; Li, Penghui; Chen, Huanwen

    2015-03-01

    Exhaled nitric oxide (eNO) is a useful biomarker of various physiological conditions, including asthma and other pulmonary diseases. Herein a fast and sensitive analytical method has been developed for the quantitative detection of eNO based on extractive electrospray ionization mass spectrometry (EESI-MS). Exhaled NO molecules selectively reacted with 2-phenyl-4, 4, 5, 5-tetramethylimidazoline-1-oxyl-3-oxide (PTIO) reagent, and eNO concentration was derived based on the EESI-MS response of 1-oxyl-2-phenyl-4, 4, 5, 5-tetramethylimidazoline (PTI) product. The method allowed quantification of eNO below ppb level (~0.02 ppbv) with a relative standard deviation (RSD) of 11.6%. In addition, eNO levels of 20 volunteers were monitored by EESI-MS over the time period of 10 hrs. Long-term eNO response to smoking a cigarette was recorded, and the observed time-dependent profile was discussed. This work extends the application of EESI-MS to small molecules (<30 Da) with low proton affinity and collision-induced dissociation efficiency, which are usually poorly visible by conventional ion trap mass spectrometers. Long-term quantitative profiling of eNO by EESI-MS opens new possibilities for the research of human metabolism and clinical diagnosis.

  7. Intact and Top-Down Characterization of Biomolecules and Direct Analysis Using Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Coupled to FT-ICR Mass Spectrometry

    PubMed Central

    Sampson, Jason S.; Murray, Kermit K.; Muddiman, David C.

    2013-01-01

    We report the implementation of an infrared laser onto our previously reported matrix-assisted laser desorption electrospray ionization (MALDESI) source with ESI post-ionization yielding multiply charged peptides and proteins. Infrared (IR)-MALDESI is demonstrated for atmospheric pressure desorption and ionization of biological molecules ranging in molecular weight from 1.2 to 17 kDa. High resolving power, high mass accuracy single-acquisition Fourier transform ion cyclotron resonance (FT-ICR) mass spectra were generated from liquid-and solid-state peptide and protein samples by desorption with an infrared laser (2.94 µm) followed by ESI post-ionization. Intact and top-down analysis of equine myoglobin (17 kDa) desorbed from the solid state with ESI post-ionization demonstrates the sequencing capabilities using IR-MALDESI coupled to FT-ICR mass spectrometry. Carbohydrates and lipids were detected through direct analysis of milk and egg yolk using both UV- and IR-MALDESI with minimal sample preparation. Three of the four classes of biological macromolecules (proteins, carbohydrates, and lipids) have been ionized and detected using MALDESI with minimal sample preparation. Sequencing of O-linked glycans, cleaved from mucin using reductive β-elimination chemistry, is also demonstrated. PMID:19185512

  8. Simultaneous determination of five minor coumarins and flavonoids in Glycyrrhiza uralensis by solid-phase extraction and high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.

    PubMed

    Qiao, Xue; Liu, Chun-Fang; Ji, Shuai; Lin, Xiong-Hao; Guo, De-An; Ye, Min

    2014-02-01

    Minor phenolic compounds in licorice (Glycyrrhiza uralensis) have recently been proved for diverse bioactivities and favorable bioavailability, indicating that they may play an important role in the therapeutic effects or herb-drug interactions of licorice. However, so far, their abundance in licorice remains unknown. In this study, a reliable solid-phase extraction coupled with a high-performance liquid chromatography and diode array detection method was established to determine the minor phenolic compounds in licorice. The analytes were enriched by a three-step solid-phase extraction method, and then separated on a YMC ODS-A column by gradient elution. Five coumarins and flavonoids were identified by electrospray ionization tandem mass spectrometry, and then quantified using high-performance liquid chromatography and diode array detection. The amounts of glycycoumarin, dehydroglyasperin C, glycyrol, licoflavonol, and glycyrin in G. uralensis were 0.81 ± 0.28, 1.25 ± 0.59, 0.20 ± 0.08, 0.12 ± 0.04, and 0.17 ± 0.08 mg/g, respectively. Abundances of these compounds in other Glycyrrhiza species (G. glabra, G. inflata, and G. yunnanesis) were remarkably lower than G. uralensis. Georg Thieme Verlag KG Stuttgart · New York.

  9. Rapid Identification of unstable acyl glucoside flavonoids of Oxytropis racemosa Turcz by high-performance liquid chromatography-diode array detection-electrospray ionisation/multi-stage mass spectrometry.

    PubMed

    Song, Shuang; Zheng, Xiu-Ping; Liu, Wei-Dong; Du, Rui-Fang; Feng, Zi-Ming; Zhang, Pei-Cheng; Bi, Li-Fu

    2013-02-01

    Oxytropis racemosa Turcz is an important minority medicine that is used mainly to improve children's indigestion, especially in inner Mongolia and Tibet. Previous studies indicated that the characteristic constituents of this plant are acylated flavonoids. Rapidly identify the characteristic chemical constituents of O. racemosa by high-performance liquid chromatography-diode array detection-electrospray ionisation/multi-stage mass spectrometry (HPLC-DAD-ESI/MS(n) ) and suggest a useful method to control the quality of this medicinal plant. In the HPLC fingerprint, 32 flavonoids were tentatively identified by a detailed analysis of their mass spectra, UV spectra and retention times. Furthermore, 13 flavonoids were confirmed by comparison with previously isolated compounds obtained from O. racemosa. In total, 32 flavonoids, including 13 flavonoids with 3-hydroxy-3-methylglutaric acid (HMG) moieties and four flavonoids with 3-malonyl moieties, were identified in the extract of O. racemosa. Among the compounds identified, 10 were characterised as new compounds for their particular acylated sugar moieties. The method described is effective for obtaining a comprehensive phytochemical profile of plants containing unstable acylated flavonoids. The method is also useful for constructing the chromatographic fingerprint of the minority medicine -O. racemosa Turcz for quality control. Copyright © 2012 John Wiley & Sons, Ltd.

  10. One-pot polymerization of monolith coated stir bar for high efficient sorptive extraction of perfluoroalkyl acids from environmental water samples followed by high performance liquid chromatography-electrospray tandem mass spectrometry detection.

    PubMed

    Yao, Xuezi; Zhou, Zhen; He, Man; Chen, Beibei; Liang, Yong; Hu, Bin

    2018-06-08

    In this work, poly(1-vinylimidazole-ethyleneglycol dimethacrylate) (poly(VI-EDMA)) monolith coated stir bars were synthesized by one-pot polymerization, and they exhibited higher extraction efficiency and faster extraction dynamics for selected PFAAs than commercial ethylene glycol modified silicone (EG-silicone) and polydimethylsiloxane (PDMS) coated stir bars. Taking eleven PFAAs as target analytes, including C4-C12 perfluoroalkyl carboxylates (PFCAs) and C6, C8 perfluoroalkane sulfonates (PFSAs), a method combining monolith-based stir bar sorptive extraction (SBSE) with high performance liquid chromatography (HPLC) - electrospray tandem mass spectrometry (ESI-MS/MS) was proposed for the determination of multiplex PFAAs in environmental water samples. Under the optimized conditions, low limits of detection (0.06-0.40 ng/L) and wide linear range (0.6-400 ng/L) were obtained for target PFAAs with. The developed method was then applied for the analysis of target PFAAs in environmental water samples, and recoveries of 80.1-117% and 80.3-122% were obtained for target PFAAs in spiked Yangtze River and East Lake water samples respectively. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Pharmacokinetic study of nobiletin and tangeretin in rat serum by high-performance liquid chromatography-electrospray ionization-mass spectrometry.

    PubMed

    Manthey, John A; Cesar, Thais B; Jackson, Erin; Mertens-Talcott, Susanne

    2011-01-12

    Nobiletin (NOB) and tangeretin (TAN), two of the main polymethoxylated flavones (PMFs) in citrus, influence a number of key biological pathways in mammalian cells. Although the impacts of NOB and TAN on glucose homeostasis and cholesterol regulation have been investigated in human clinical trials, much information is still lacking about the metabolism and oral bioavailability of these compounds in animals. In this study, NOB and TAN were administered to rats by gavage and intraperitoneal (ip) injection, and the blood serum concentrations of these compounds and their main metabolites were monitored by high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS). In addition to the administered compounds, two metabolites of TAN and eight metabolites of NOB were detected and measured over 24 h. With identical oral doses, nearly 10-fold higher absorption of NOB occurred compared to TAN. For both compounds, maximum levels of glucuronidated metabolites occurred in the blood serum at later time points (∼5-8 h) compared to the earlier T(max) values for NOB and TAN. In most cases the glucuronides occurred at substantially higher concentrations than the aglycone metabolites. Low levels of NOB and TAN and their metabolites were detectable in rat blood serum even at 24 h after treatment.

  12. Liquid chromatography-electrospray mass spectrometry of beta-carotene and xanthophylls. Validation of the analytical method.

    PubMed

    Careri, M; Elviri, L; Mangia, A

    1999-08-27

    The investigation of beta-carotene and the xanthophylls beta-cryptoxanthin, lutein, zeaxanthin, canthaxanthin and astaxanthin using reversed-phase liquid chromatography-electrospray mass spectrometry interfaced with TurboIonspray (LC-TurboISP-MS) is described. Two narrow-bore C18 columns connected in series and an isocratic solvent system containing acetonitrile-methanol (0.1 M ammonium acetate)-dichloromethane at a flow-rate of 300 microl/min (without splitting) were used. Operating in the positive-ion mode over m/z 500-650, the effects on the formation of the molecular ion species or adduct ions and the MS detector response were investigated for carotenoids, varying the orifice plate voltage, the ring voltage and the ISP voltage. Both conventional ISP and TurboISP were performed; using the TurboISP-MS system, ionization efficiency increased with respect to ISP-MS, particularly at the highest temperature (500 degrees C). Good results were particularly obtained for beta-carotene, which was detectable at the low ng level, without the use of solution-phase oxidants. Using LC columns and acquiring in single-ion monitoring mode, detection limits were estimated to be in the 0.1-1 ng range; dynamic range was established between one- and two-orders of magnitude. Better sensitivity under positive-ion than negative-ion conditions was demonstrated.

  13. Comprehensive quantification of triacylglycerols in soybean seeds by electrospray ionization mass spectrometry with multiple neutral loss scans

    DOE PAGES

    Li, Maoyin; Butka, Emily; Wang, Xuemin

    2014-10-10

    Soybean seeds are an important source of vegetable oil and biomaterials. The content of individual triacylglycerol species (TAG) in soybean seeds is difficult to quantify in an accurate and rapid way. The present study establishes an approach to quantify TAG species in soybean seeds utilizing an electrospray ionization tandem mass spectrometry with multiple neutral loss scans. Ten neutral loss scans were performed to detect the fatty acyl chains of TAG, including palmitic (P, 1650), linolenic (Ln, 1853), linoleic (L, 1852), oleic (O, 1851), stearic (S, 1850), eicosadienoic (2052), gadoleic (2051), arachidic (2050), erucic (2251), and behenic (2250). The abundance ofmore » ten fatty acyl chains at 46 TAG masses (mass-to-charge ratio, m/z) were determined after isotopic deconvolution and correction by adjustment factors at each TAG mass. The direct sample infusion and multiple internal standards correction allowed a rapid and accurate quantification of TAG species. Ninety-three TAG species were resolved and their levels were determined.The most abundant TAG species were LLL, OLL, LLLn, PLL, OLLn, OOL, POL, and SLL. Many new species were detected and quantified. As a result, this shotgun lipidomics approach should facilitate the study of TAG metabolism and genetic breeding of soybean seeds for desirable TAG content and composition.« less

  14. Direct Standard-Free Quantitation of Tamiflu® and Other Pharmaceutical Tablets using Clustering Agents with Electrospray Ionization Mass Spectrometry

    PubMed Central

    Flick, Tawnya G.; Leib, Ryan D.; Williams, Evan R.

    2010-01-01

    Accurate and rapid quantitation is advantageous to identify counterfeit and substandard pharmaceutical drugs. A standard-free electrospray ionization mass spectrometry method is used to directly determine the dosage in the prescription and over-the-counter drugs, Tamiflu®, Sudafed®, and Dramamine®. A tablet of each drug was dissolved in aqueous solution, filtered, and introduced into solutions containing a known concentration of either L-tryptophan, L-phenylalanine or prednisone as clustering agents. The active ingredient(s) incorporates statistically into large clusters of the clustering agent where effects of differential ionization/detection are substantially reduced. From the abundances of large clusters, the dosages of the active ingredients in each of the tablets were determined to typically better than 20% accuracy even when the ionization/detection efficiency of the individual components differed by over 100×. Although this unorthodox method for quantitation is not as accurate as using conventional standards, it has the advantages that it is fast, it can be applied to mixtures where the identities of the analytes are unknown, and it can be used when suitable standards may not be readily available, such as schedule I or II controlled substances or new designer drugs that have not previously been identified. PMID:20092258

  15. A general analytical strategy for the characterization of phenolic compounds in fruit juices by high-performance liquid chromatography with diode array detection coupled to electrospray ionization and triple quadrupole mass spectrometry.

    PubMed

    Abad-García, Beatriz; Berrueta, Luis A; Garmón-Lobato, Sergio; Gallo, Blanca; Vicente, Francisca

    2009-07-10

    In the present study, a methodology based on liquid chromatography with diode array detection (HPLC/DAD) coupled to an electrospray ionization (ESI) interface and a triple quadrupole mass spectrometer for the simultaneous identification of phenolic compounds in fruit juices has been developed. 72 available phenolic compound standards from diverse families present in fruits have been studied in order to analyze their fragmentation pattern. As a result, a general strategy for the characterization of unknown phenolic compounds in fruit juices was designed: (i) taking into account its UV-visible spectrum and elution order, assign the unknown polyphenol to a polyphenol class, (ii) identify the quasi-molecular ion using positive and negative MS spectra, being supported by adducts generated with solvent or sodium and molecular complexes, (iii) determinate the pattern of glycosylation in positive mode using ESI(+)-CID MS/MS product ion scan experiments, selecting the quasi-molecular ion as precursor ion, and finally, (iv) study the identity of the aglycone through ESI(+)-CID MS/MS product ion spectra from the protonated aglycone, [Y(0)](+). This strategy was successfully employed for the characterization of known and unknown phenolic compounds in juices from 17 different fruits.

  16. Characterization of limonin glucoside metabolites from human prostate cell culture medium using high-performance liquid chromatography/electrospray ionization mass spectrometry and tandem mass spectrometry.

    PubMed

    Tian, Qingguo; Kent, Kyle D; Bomser, Joshua A; Schwartz, Steven J

    2004-01-01

    The metabolism of limonin 17-beta-D-glucopyranoside (LG) by non-cancerous (RWPE-1) and cancerous (PC-3) human prostate epithelial cells was investigated using high-performance liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) with in-source fragmentation and tandem mass spectrometry (MS/MS). During positive ion LC/ESI-MS, LG formed an abundant sodiated species ([M+Na]+) while the protonated molecule was barely observable. [M+Na]+ further fragmented into the less abundant [LARL+H]+ and a predominantly protonated aglycone molecule (limonin) due to in-source fragmentation. The major metabolite, limonin A-ring lactone (LARL), formed an abundant protonated molecule that was fragmented into a protonated molecule of limonin by loss of one molecule of water. In MS/MS by collisionally activated dissociation (CAD), LG produced the sodiated aglycone, [aglycone+Na]+, while LARL fragmented into [M+H]+ of limonin and fragment ions resulted by further loss of water, carbon monoxide and carbon dioxide, indicating the presence of oxygenated-ring structures. The limits of detection of LG were 0.4 and 20 fmol in selected-ion monitoring (SIM) and selected-reaction monitoring (SRM) detection, respectively. Copyright 2004 John Wiley & Sons, Ltd.

  17. Steroid hormone profiles of urban and tidal rivers using LC/MS/MS equipped with electrospray ionization and atmospheric pressure photoionization sources.

    PubMed

    Yamamoto, Atsushi; Kakutani, Naoya; Yamamoto, Kohji; Kamiura, Toshikazu; Miyakoda, Hidekazu

    2006-07-01

    A highly sensitive and uncomplicated method of analyzing steroidal hormones in river and estuarine water samples was developed using a liquid chromatography tandem mass spectrometer equipped with an electrospray ionization (ESI) source and atmospheric pressure photoionization (APPI) source. Steroidal hormones included not only estrogen but also androgen and conjugates of these two. APPI displayed greater sensitivity than ESI for most of the unconjugated steroids examined, with very high sensitivity for testosterone and 4-androstene-3,17-dione in particular. For conjugated hormones, in contrast, ESI was more effective. The method developed was applied to the determination of hormones in the rivers of Osaka City and their estuaries, where the hormones detected were affected by the effluent from municipal wastewater treatment plants (WWTPs), and hormone concentration values were comparable to those reported in previous studies of such effluent. Because of the two-way flow and stagnancy of streams and watercourses, continuous input of steroidal hormones from WWTPs seems to bring about local accumulation. Levels of androgen were 1 order of magnitude lower than those of estrogen. Estrone, estrone 3-sulfate, and 4-androstene-3,17-dione were detected in almost all water samples, with maxima of 51, 5.1, and 6.4 ng L(-1), respectively.

  18. Simultaneous determination of water-soluble vitamins in selected food matrices by liquid chromatography/electrospray ionization tandem mass spectrometry.

    PubMed

    Gentili, Alessandra; Caretti, Fulvia; D'Ascenzo, Giuseppe; Marchese, Stefano; Perret, Daniela; Di Corcia, Daniele; Rocca, Lucia Mainero

    2008-07-01

    A rapid, simple and sensitive method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) with an electrospray ionization (ESI) source for the simultaneous analysis of fourteen water-soluble vitamins (B1, B2, two B3 vitamers, B5, five B6 vitamers, B8, B9, B12 and C) in various food matrices, i.e. maize flour, green and golden kiwi and tomato pulp, is presented here. Analytes were separated by ion-suppression reversed-phase liquid chromatography in less than 10 min and detected in positive ion mode. Sensitivity and specificity of this method allowed two important results to be achieved: (i) limits of detection of the analytes at ng g(-1) levels (except for vitamin C); (ii) development of a rapid sample treatment that minimizes analyte exposition to light, air and heat, eliminating any step of extract concentration. Analyte recovery depended on the type of matrix. In particular, recovery of the analytes in maize flour was > or =70%, with the exception of vitamin C, pyridoxal-5'-phosphate and vitamin B9 (ca 40%); with tomato pulp, recovery was > or =64%, except for vitamin C (41%); with kiwi, recovery was > or =73%, except for nicotinamide (ca. 30%).

  19. Detection of Gelatin Adulteration in Traditional Chinese Medicine: Analysis of Deer-Horn Glue by Rapid-Resolution Liquid Chromatography-Triple Quadrupole Mass Spectrometry

    PubMed Central

    Chen, Jia; Cheng, Xian-Long; Wei, Feng; Zhang, Qian-Qian; Li, Ming-Hua; Ma, Shuang-Cheng

    2015-01-01

    Simultaneous identification of donkey-hide gelatin and bovine-hide gelatin in deer-horn glue was established by rapid-resolution liquid chromatography-triple quadrupole mass spectrometry. Water containing 1% NH4HCO3 was used for sample dissolution and trypsin was used for hydrolysis of the gelatins. After separation by a SB-C18 reversed-phase analytical column, collagen marker peptides were detected by mass spectrometry in positive electrospray ionization mode with multiple reaction monitoring. The method was specific, precise and reliable, and suitable for detection of adulterants derived from donkey-hide gelatin and bovine-hide gelatin in deer-horn glue. PMID:26504613

  20. Average [O II] nebular emission associated with Mg II absorbers: dependence on Fe II absorption

    NASA Astrophysics Data System (ADS)

    Joshi, Ravi; Srianand, Raghunathan; Petitjean, Patrick; Noterdaeme, Pasquier

    2018-05-01

    We investigate the effect of Fe II equivalent width (W2600) and fibre size on the average luminosity of [O II] λλ3727, 3729 nebular emission associated with Mg II absorbers (at 0.55 ≤ z ≤ 1.3) in the composite spectra of quasars obtained with 3 and 2 arcsec fibres in the Sloan Digital Sky Survey. We confirm the presence of strong correlations between [O II] luminosity (L_{[O II]}) and equivalent width (W2796) and redshift of Mg II absorbers. However, we show L_{[O II]} and average luminosity surface density suffer from fibre size effects. More importantly, for a given fibre size, the average L_{[O II]} strongly depends on the equivalent width of Fe II absorption lines and found to be higher for Mg II absorbers with R ≡W2600/W2796 ≥ 0.5. In fact, we show the observed strong correlations of L_{[O II]} with W2796 and z of Mg II absorbers are mainly driven by such systems. Direct [O II] detections also confirm the link between L_{[O II]} and R. Therefore, one has to pay attention to the fibre losses and dependence of redshift evolution of Mg II absorbers on W2600 before using them as a luminosity unbiased probe of global star formation rate density. We show that the [O II] nebular emission detected in the stacked spectrum is not dominated by few direct detections (i.e. detections ≥3σ significant level). On an average, the systems with R ≥ 0.5 and W2796 ≥ 2 Å are more reddened, showing colour excess E(B - V) ˜ 0.02, with respect to the systems with R < 0.5 and most likely trace the high H I column density systems.

  1. Role of near ultraviolet wavelength measurements in the detection and retrieval of absorbing aerosols from space

    NASA Astrophysics Data System (ADS)

    Mukai, Sonoyo; Fujito, Toshiyuki; Nakata, Makiko; Sano, Itaru

    2017-10-01

    Aerosol remote sensing by ultraviolet (UV) wavelength is established by a Total Ozone Mapping Spectrometer (TOMS) mounted on the long-life satellite Nimbus-7 and continues to make observations using Ozone monitoring instrument (OMI) located on the Aura satellite. For example, TOMS demonstrated that UV radiation (0.331 and 0.360 μm) could easily detect absorbing particles such as mineral dust or smoke aerosols. TOMS-AI (absorbing aerosol index) has been used to identify the absorbing aerosols from space. For an upcoming mission, JAXA/GCOM-C will have the polarization sensor SGLI boarded in December 2017. The SGLI has multi (19)-channels including near UV (0.380 μm) and violet (0.412 μm) wavelengths. This work intends to examine the role of near UV data in the detection of absorbing aerosols similar to TOMS-AI played. In practice, the measurements by GLI mounted on the short Japanese mission JAXA/ADEOS-2, whose data archive period was just 8 months from April to October in 2003, are available for simulation of SGLI data because ADEOS-2/GLI installed near UV and violet channels. First of all, the ratio of data at 0.412 μm to that at 0.380 μm is examined as an indicator to detect absorbing aerosols on a global scale during ADEOS-2 era. It is noted that our research group has developed an efficient algorithm for aerosol retrieval in hazy episodes (dense concentrations of atmospheric aerosols). It can be said that at least this work is an attempt to grasp the biomass burning plumes from the satellite.

  2. Sheathless interface to match flow rate of capillary electrophoresis with electrospray mass spectrometry using regular-sized capillary.

    PubMed

    Yin, Yue; Li, Gongyu; Guan, Yafeng; Huang, Guangming

    2016-08-01

    The flow rate match has been a great challenge when coupling capillary electrophoresis (CE) with electrospray ionization mass spectrometry (ESI-MS). Conventional CE-ESI-MS interfaces used liquid sheath flow, narrowed capillary or additional pressure to meet this requirement; sacrifice of either capillary inner diameter (i.d.) or separation efficiency is often inevitable. Thus, a regular-sized capillary-based sheathless interface would be attractive for flow rate match in CE-MS. The regular-sized capillary-based CE-MS interface was achieved by coupling CE with induced electrospray ionization (iESI) which was stimulated by the fact that the iESI could both achieve flow rate down to 0.2 μL/min and retain ionization efficiency. The CE-iESI-MS interface was completed with an intact separation capillary, outside the outlet end of which a metal electrode was attached for the application of alternating current (ac) high voltage (HV). The feasibility of this CE-iESI-MS interface was demonstrated through the stable total ion chromatograms obtained by continuous CE infusion of tripropylamine with regular-sized capillaries. Tripropylamine and atenolol were separated and detected successfully in phosphate buffer solution (PBS) by CE-iESI-MS using a 50 or 75 μm i.d. capillary. Furthermore, this new interface showed a better signal-to-noise (S/N) of 3 to 7 times enhancement compared with another sheathless CE-ESI-MS interface that using one high voltage for both separation and electrospray when analyzing the mixture of tripropylamine and proline in NH4 OAc buffer. In addition, the reproducibility of this interface gave satisfactory results with relative standard deviation (RSD) in retention time in the range between 1% and 3%. The novel sheathless CE-MS interface introduced here could match conventional electroosmotic flow (EOF) with electrospray which could also preserve the separation efficiency and sensitivity of CE-MS. This newly developed CE-iESI-MS interface was also demonstrated to be effective for different buffers, PBS and NH4 OAc, without any additives such as methanol and acetic acid. Hence, we believe that this sheathless CE-MS interface could be operated with other nonvolatile and volatile buffers. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Characterization of Ce SUP 3+-tributyl phosphate coordination complexes produced by fused droplet electrospray ionization with a target capillary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gary S. Groenewold; Jean-Jacques Gaumet

    2011-12-01

    Coordination complexes containing Ce(III) and tri-n-butyl phosphate (TBP) in the 1+, 2+ and 3+ charge states were generated using desorption electrospray ionization (DESI) mass spectrometry, in which the analyte solutions were supplied via a target capillary orthogonally situated with respect to the electrospray. Comparison with direct electrospray (ESI) showed that the same coordination complexes were produced in each experiment, and could be described by the general formula [Ce(NO3)m=0-2(TBP)n](3-m)+. This result indicates that DESI has utility for measuring metal speciation for metal ligand solutions where the gas-phase complexes generated by ESI have been correlated with solution speciation. Such an application wouldmore » be useful for analyses where it is desirable to limit the total amount of metal being handled, or that have solvent systems that are not readily amenable to ESI. Both the direct ESI and DESI mass spectra showed similar trends with respect to the TBP:Ce ratio, viz. high values tend to favor formation of a larger fraction of the 1+ species, and the 2+ and 3+ species become relatively more important as the ratio is decreased. Within individual charge state ion envelopes, lower TBP:Ce ratios produce coordination complexes with fewer ligands, a trend also seen using both approaches. These trends again point toward strong similarity between the direct ESI and DESI analyses of the metal-ligand solutions. The DESI experiments were less sensitive for measuring the coordination complexes compared to the direct ESI experiments, by a factor of 10 - 100 depending on whether minimum detectable concentration or absolute ion abundances were considered. Nevertheless, mid-picomolar quantities of coordination complexes were measured using the target capillary, indicating that sensitivity would be sufficient for measuring species in many industrial separations processes.« less

  4. The HI Environment of Nearby Lyman-alpha Absorbers

    NASA Technical Reports Server (NTRS)

    VanGorkom, J. H.; Carilli, C. L.; Stocke, John T.; Perlman, Eric S.; Shull, J. Michael

    1996-01-01

    We present the results of a VLA and WSRT search for H I emission from the vicinity of seven nearby clouds, which were observed in Ly-alpha absorption with HST toward Mrk 335, Mrk 501, and PKS 2155-304. Around the absorbers, we searched a volume of 4O' x 40' x 1000 km/s; for one of the absorbers we probed a velocity range of only 600 km/s. The H I mass sensitivity (5 sigma) very close to the lines of sight varies from 5 x 10(exp 6) solar mass at best to 5 x 10(exp 8) solar mass at worst. We detected H I emission in the vicinity of four out of seven absorbers. The closest galaxy we find to the absorbers is a small dwarf galaxy at a projected distance of 68 h(exp -1) kpc from the sight line toward Mrk 335. This optically uncataloged galaxy has the same velocity (V = 1970 km/s) as one of the absorbers, is fainter than the SMC, and has an H I mass of only 4 x 10(exp 7) solar mass. We found a somewhat more luminous galaxy at exactly the velocity (V = 5100 km/s) of one of the absorbers toward PKS 2155-304 at a projected distance of 230 h(exp -1) kpc from the sight line. Two other, stronger absorbers toward PKS 2155-304 at V approx. 17,000 km/s appear to be associated with a loose group of three bright spiral galaxies, at projected distances of 300 to 600 h(exp -1) kpc. These results support the conclusions emerging from optical searches that most nearby Ly-alpha forest clouds trace the large-scale structures outlined by the optically luminous galaxies, although this is still based on small-number statistics. We do not find any evidence from the H I distribution or kinematics that there is a physical association between an absorber and its closest galaxy. While the absorbing clouds are at the systemic velocity of the galaxies, the H I extent of the galaxies is fairly typical, and at least an order of magnitude smaller than the projected distance to the sight line at which the absorbers are seen. On the other hand, we also do not find evidence against such a connection. In total, we detected H I emission from five galaxies, of which two were previously uncataloged and one did not have a known redshift. No H I emission was detected from the vicinity of the two absorbers, which are located in a void and a region of very low galaxy density; but the limits are somewhat less stringent than for the other sight lines. These results are similar to what has been found in optically unbiased H I surveys. Thus, presence of Ly-alpha absorbers does not significantly alter the H I detection rate in their environment.

  5. [Design and experiment of micro biochemical detector based on micro spectrometer].

    PubMed

    Yu, Qing-hua; Wen, Zhi-yu; Chen, Gang; Dai, Wei-wei; Liu, Nian-ci; Wu, Xin

    2012-03-01

    According to the requirements of rapid detection of important life parameters for the sick and wounded, a new micro bio-chemical detection configuration was proposed utilizing continuous spectroscopy analysis, which was founded on MOEMS and embedded technology. The configuration was developed as so much research work was carried out on the detecting objects and methods. Important parameters such as stray light, absorbance linearity, absorbance ratability, stability and temperature accuracy of the instrument were tested, which are all in good agreement with the design requirements. Clinic tests show that it can detect multiple life parameters quickly (Na+, GLU, Hb eg.).

  6. Novel electrosprayed nanospherules for enhanced aqueous solubility and oral bioavailability of poorly water-soluble fenofibrate

    PubMed Central

    Yousaf, Abid Mehmood; Mustapha, Omer; Kim, Dong Wuk; Kim, Dong Shik; Kim, Kyeong Soo; Jin, Sung Giu; Yong, Chul Soon; Youn, Yu Seok; Oh, Yu-Kyoung; Kim, Jong Oh; Choi, Han-Gon

    2016-01-01

    Purpose The purpose of the present research was to develop a novel electrosprayed nanospherule providing the most optimized aqueous solubility and oral bioavailability for poorly water-soluble fenofibrate. Methods Numerous fenofibrate-loaded electrosprayed nanospherules were prepared with polyvinylpyrrolidone (PVP) and Labrafil® M 2125 as carriers using the electrospray technique, and the effect of the carriers on drug solubility and solvation was assessed. The solid state characterization of an optimized formulation was conducted by scanning electron microscopy, powder X-ray diffraction, differential scanning calorimetry, and Fourier transform infrared spectroscopic analyses. Oral bioavailability in rats was also evaluated for the formulation of an optimized nanospherule in comparison with free drug and a conventional fenofibrate-loaded solid dispersion. Results All of the electrosprayed nanospherule formulations had remarkably enhanced aqueous solubility and dissolution compared with free drug. Moreover, Labrafil M 2125, a surfactant, had a positive influence on the solubility and dissolution of the drug in the electrosprayed nanospherule. Increases were observed as the PVP/drug ratio increased to 4:1, but higher ratios gave no significant increases. In particular, an electrosprayed nanospherule composed of fenofibrate, PVP, and Labrafil M 2125 at the weight ratio of 1:4:0.5 resulted in a particle size of <200 nm with the drug present in the amorphous state. It demonstrated the highest solubility (32.51±2.41 μg/mL), an excellent dissolution (~85% in 10 minutes), and an oral bioavailability ~2.5-fold better than that of the free drug. It showed similar oral bioavailability compared to the conventional solid dispersion. Conclusion Electrosprayed nanospherules, which provide improved solubility and bioavailability, are promising drug delivery tools for oral administration of poorly water-soluble fenofibrate. PMID:26834471

  7. Novel electrosprayed nanospherules for enhanced aqueous solubility and oral bioavailability of poorly water-soluble fenofibrate.

    PubMed

    Yousaf, Abid Mehmood; Mustapha, Omer; Kim, Dong Wuk; Kim, Dong Shik; Kim, Kyeong Soo; Jin, Sung Giu; Yong, Chul Soon; Youn, Yu Seok; Oh, Yu-Kyoung; Kim, Jong Oh; Choi, Han-Gon

    2016-01-01

    The purpose of the present research was to develop a novel electrosprayed nanospherule providing the most optimized aqueous solubility and oral bioavailability for poorly water-soluble fenofibrate. Numerous fenofibrate-loaded electrosprayed nanospherules were prepared with polyvinylpyrrolidone (PVP) and Labrafil(®) M 2125 as carriers using the electrospray technique, and the effect of the carriers on drug solubility and solvation was assessed. The solid state characterization of an optimized formulation was conducted by scanning electron microscopy, powder X-ray diffraction, differential scanning calorimetry, and Fourier transform infrared spectroscopic analyses. Oral bioavailability in rats was also evaluated for the formulation of an optimized nanospherule in comparison with free drug and a conventional fenofibrate-loaded solid dispersion. All of the electrosprayed nanospherule formulations had remarkably enhanced aqueous solubility and dissolution compared with free drug. Moreover, Labrafil M 2125, a surfactant, had a positive influence on the solubility and dissolution of the drug in the electrosprayed nanospherule. Increases were observed as the PVP/drug ratio increased to 4:1, but higher ratios gave no significant increases. In particular, an electrosprayed nanospherule composed of fenofibrate, PVP, and Labrafil M 2125 at the weight ratio of 1:4:0.5 resulted in a particle size of <200 nm with the drug present in the amorphous state. It demonstrated the highest solubility (32.51±2.41 μg/mL), an excellent dissolution (~85% in 10 minutes), and an oral bioavailability ~2.5-fold better than that of the free drug. It showed similar oral bioavailability compared to the conventional solid dispersion. Electrosprayed nanospherules, which provide improved solubility and bioavailability, are promising drug delivery tools for oral administration of poorly water-soluble fenofibrate.

  8. Neutron reflectometry on highly absorbing films and its application to 10B4C-based neutron detectors

    PubMed Central

    Piscitelli, F.; Khaplanov, A.; Devishvili, A.; Schmidt, S.; Höglund, C.; Birch, J.; Dennison, A. J. C.; Gutfreund, P.; Hall-Wilton, R.; Van Esch, P.

    2016-01-01

    Neutron reflectometry is a powerful tool used for studies of surfaces and interfaces. The absorption in the typical studied materials is neglected and this technique is limited only to the reflectivity measurement. For strongly absorbing nuclei, the absorption can be directly measured by using the neutron-induced fluorescence technique which exploits the prompt particle emission of absorbing isotopes. This technique is emerging from soft matter and biology where highly absorbing nuclei, in very small quantities, are used as a label for buried layers. Nowadays, the importance of absorbing layers is rapidly increasing, partially because of their application in neutron detection; a field that has become more active also due to the 3He-shortage. We extend the neutron-induced fluorescence technique to the study of layers of highly absorbing materials, in particular 10B4C. The theory of neutron reflectometry is a commonly studied topic; however, when a strong absorption is present the subtle relationship between the reflection and the absorption of neutrons is not widely known. The theory for a general stack of absorbing layers has been developed and compared to measurements. We also report on the requirements that a 10B4C layer must fulfil in order to be employed as a converter in neutron detection. PMID:26997902

  9. Structural characterization of trace stilbene glycosides in Lysidice brevicalyx Wei using liquid chromatography/diode-array detection/electrospray ionization tandem mass spectrometry.

    PubMed

    Hu, Youcai; Qu, Jing; Liu, Yuanyan; Yu, Shishan; Li, Jianbei; Zhang, Jinlan; Du, Dan

    2010-01-01

    The mass fragmentation patterns of stilbene glycosides isolated from the genus Lysidice were investigated by negative ion electrospray ionization tandem mass spectrometry, and the influence of collision energy on their fragmentation behavior is discussed. It is found that the presence of the Y(0)(-) and B(0)(-) ions in the MS(2) spectra is characteristic for 1-->6 linked diglycosyl stilbenes, while the Y(0)(-), Y(1)(-), and Z(1)(-) ions are representative ions of 1-->2 linked diglycosyl stilbenes. These results indicate that ESI-MS(n) in the negative ion mode can be used to differentiate 1-->6 and 1-->2 linked diglycosyl stilbenes. Based on the fragmentation rules, 9 new trace constituents were identified or tentatively characterized in a fraction of Lysidice brevicalyx by using HPLC/HRMS and HPLC-DAD/ESI-MS(n). The results of the present study can assist in on-line structural identification of analogous constituents and targeted isolation of novel compounds from crude plant extracts.

  10. Analysis of phenolic choline esters from seeds of Arabidopsis thaliana and Brassica napus by capillary liquid chromatography/electrospray- tandem mass spectrometry.

    PubMed

    Böttcher, Christoph; von Roepenack-Lahaye, Edda; Schmidt, Jürgen; Clemens, Stephan; Scheel, Dierk

    2009-04-01

    Total phenolic choline ester fractions prepared from seeds of Arabidopsis thaliana and Brassica napus were analyzed by capillary LC/ESI-QTOF-MS and direct infusion ESI-FTICR-MS. In addition to the dominating sinapoylcholine, 30 phenolic choline esters could be identified based on accurate mass measurements, interpretation of collision-induced dissociation (CID) mass spectra, and synthesis of selected representatives. The compounds identified so far include substituted hydroxycinnamoyl- and hydroxybenzoylcholines, respective monohexosides as well as oxidative coupling products of phenolic choline esters and monolignols. Phenolic choline esters are well separable by reversed-phase liquid chromatography and sensitively detectable using electrospray ionization mass spectrometry in positive ion mode. CID mass spectra obtained from molecular ions facilitate the characterization of both the type and substitution pattern of such compounds. Therefore, LC/ESI-MS/MS represents a valuable tool for comprehensive qualitative and quantitative analysis of this compound class. Copyright (c) 2009 John Wiley & Sons, Ltd.

  11. Mass spectrometry imaging for visualizing organic analytes in food.

    PubMed

    Handberg, Eric; Chingin, Konstantin; Wang, Nannan; Dai, Ximo; Chen, Huanwen

    2015-01-01

    The demand for rapid chemical imaging of food products steadily increases. Mass spectrometry (MS) is featured by excellent molecular specificity of analysis and is, therefore, a very attractive method for chemical profiling. MS for food imaging has increased significantly over the past decade, aided by the emergence of various ambient ionization techniques that allow direct and rapid analysis in ambient environment. In this article, the current status of food imaging with MSI is reviewed. The described approaches include matrix-assisted laser desorption/ionization (MALDI), but emphasize desorption atmospheric pressure photoionization (DAPPI), electrospray-assisted laser desorption/ionization (ELDI), probe electrospray ionization (PESI), surface desorption atmospheric pressure chemical ionization (SDAPCI), and laser ablation flowing atmospheric pressure afterglow (LA-FAPA). The methods are compared with regard to spatial resolution; analysis speed and time; limit of detection; and technical aspects. The performance of each method is illustrated with the description of a related application. Specific requirements in food imaging are discussed. © 2014 Wiley Periodicals, Inc.

  12. Quantitative analysis of glycosaminoglycans, chondroitin/dermatan sulfate, hyaluronic acid, heparan sulfate, and keratan sulfate by liquid chromatography-electrospray ionization-tandem mass spectrometry.

    PubMed

    Osago, Harumi; Shibata, Tomoko; Hara, Nobumasa; Kuwata, Suguru; Kono, Michihaya; Uchio, Yuji; Tsuchiya, Mikako

    2014-12-15

    We developed a method using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) with a selected reaction monitoring (SRM) mode for simultaneous quantitative analysis of glycosaminoglycans (GAGs). Using one-shot analysis with our MS/MS method, we demonstrated the simultaneous quantification of a total of 23 variously sulfated disaccharides of four GAG classes (8 chondroitin/dermatan sulfates, 1 hyaluronic acid, 12 heparan sulfates, and 2 keratan sulfates) with a sensitivity of less than 0.5 pmol within 20 min. We showed the differences in the composition of GAG classes and the sulfation patterns between porcine articular cartilage and yellow ligament. In addition to the internal disaccharides described above, some saccharides derived from the nonreducing terminal were detected simultaneously. The simultaneous quantification of both internal and nonreducing terminal saccharides could be useful to estimate the chain length of GAGs. This method would help to establish comprehensive "GAGomic" analysis of biological tissues. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Inductively coupled plasma mass spectrometry and electrospray mass spectrometry for speciation analysis: applications and instrumentation

    NASA Astrophysics Data System (ADS)

    Rosen, Amy L.; Hieftje, Gary M.

    2004-02-01

    To gain an understanding of the function, toxicity and distribution of trace elements, it is necessary to determine not only the presence and concentration of the elements of interest, but also their speciation, by identifying and characterizing the compounds within which each is present. For sensitive detection of compounds containing elements of interest, inductively coupled plasma mass spectrometry (ICP-MS) is a popular method, and for identification of compounds via determination of molecular weight, electrospray ionization mass spectrometry (ESI-MS) is gaining increasing use. ICP-MS and ESI-MS, usually coupled to a separation technique such as chromatography or capillary electrophoresis, have already been applied to a large number of research problems in such diverse fields as environmental chemistry, nutritional science, and bioinorganic chemistry, but a great deal of work remains to be completed. Current areas of research to which ICP-MS and ESI-MS have been applied are discussed, and the existing instrumentation used to solve speciation problems is described.

  14. Identification of sinensetin metabolites in rat urine by an isotope-labeling method and ultrahigh-performance liquid chromatography-electrospray ionization mass spectrometry.

    PubMed

    Wei, Guor-Jien; Sheen, Jenn-Feng; Lu, Wen-Chien; Hwang, Lucy Sun; Ho, Chi-Tang; Lin, Ching-I

    2013-05-29

    Sinensetin (SIN), one of the major polymethoxyflavones (PMFs) contained mainly in the citrus peels, has been reported to possess various bioactivities, including antifungal, antimutagenic, anticancer, and anti-inflammatory activities. Although the biotransformation of SIN in fungi and insects has been reported, the information about the metabolism of SIN in mammals is still unclear. In this study, formation of SIN metabolites in rats was investigated. Four isotope-labeled SINs ([4'-D3]SIN, [3'-D3]SIN, [5-D3]SIN, and [6-D3]SIN) were synthesized and administered to rat. The urine samples were collected and main metabolites were monitored by ultrahigh-performance liquid chromatography-electrospray ionization mass spectrometry. The administered compound and four SIN metabolites were detected in rat urine. These metabolites were identified as 4'-hydroxy-5,6,7,3'-tetramethoxyflavone, 5-hydroxy-6,7,3',4'-tetramethoxyflavone, 6-hydroxy-5,7,3',4'-tetramethoxyflavone, and 7-hydroxy-5,6,3',4'-tetramethoxyflavone sulfate.

  15. Electrospray ion source with reduced analyte electrochemistry

    DOEpatents

    Kertesz, Vilmos [Knoxville, TN; Van Berkel, Gary [Clinton, TN

    2011-08-23

    An electrospray ion (ESI) source and method capable of ionizing an analyte molecule without oxidizing or reducing the analyte of interest. The ESI source can include an emitter having a liquid conduit, a working electrode having a liquid contacting surface, a spray tip, a secondary working electrode, and a charge storage coating covering partially or fully the liquid contacting surface of the working electrode. The liquid conduit, the working electrode and the secondary working electrode can be in liquid communication. The electrospray ion source can also include a counter electrode proximate to, but separated from, said spray tip. The electrospray ion source can also include a power system for applying a voltage difference between the working electrodes and a counter-electrode. The power system can deliver pulsed voltage changes to the working electrodes during operation of said electrospray ion source to minimize the surface potential of the charge storage coating.

  16. Electrospray ion source with reduced analyte electrochemistry

    DOEpatents

    Kertesz, Vilmos; Van Berkel, Gary J

    2013-07-30

    An electrospray ion (ESI) source and method capable of ionizing an analyte molecule without oxidizing or reducing the analyte of interest. The ESI source can include an emitter having a liquid conduit, a working electrode having a liquid contacting surface, a spray tip, a secondary working electrode, and a charge storage coating covering partially or fully the liquid contacting surface of the working electrode. The liquid conduit, the working electrode and the secondary working electrode can be in liquid communication. The electrospray ion source can also include a counter electrode proximate to, but separated from, said spray tip. The electrospray ion source can also include a power system for applying a voltage difference between the working electrodes and a counter-electrode. The power system can deliver pulsed voltage changes to the working electrodes during operation of said electrospray ion source to minimize the surface potential of the charge storage coating.

  17. Nanoparticle assembly on patterned "plus/minus" surfaces from electrospray of colloidal dispersion.

    PubMed

    Lenggoro, I Wuled; Lee, Hye Moon; Okuyama, Kikuo

    2006-11-01

    Selective deposition of metal (Au) and oxide (SiO2) nanoparticles with a size range of 10-30 nm on patterned silicon-silicon oxide substrate was performed using the electrospray method. Electrical charging characteristics of particles produced by the electrospray and patterned area created by contact charging of the electrical conductor with non- or semi-conductors were investigated. Colloidal droplets were electrosprayed and subsequently dried as individual nanoparticles which then were deposited on substrates, and observed using field emission-scanning electron microscopy. The number of elementary charge units on particles generated by the electrospray was 0.4-148, and patterned area created by contact charging contained sufficient negative charges to attract multiple charged particles. Locations where nanoparticles were (reversibly) deposited depended on voltage polarity applied to the spraying colloidal droplet and the substrate, and the existence of additional ions such as those from a stabilizer.

  18. Preparation of inorganic/organic polymer hybrid microcapsules with high encapsulation efficiency by an electrospray technique.

    PubMed

    Yunoki, Ayumi; Tsuchiya, Eiko; Fukui, Yu; Fujii, Akihiro; Maruyama, Tatsuo

    2014-08-13

    Microcapsules composed of calcium phosphate and chitosan were prepared in a single step by electrospraying. An aqueous solution containing calcium chloride and chitosan was electrosprayed into a phosphate solution to form a calcium phosphate shell on the sprayed droplets. The resulting microcapsules were 350 μm in average diameter. Investigation using fluorescently labeled chitosan and XRD measurements revealed that the shells of the microcapsules were composed of calcium phosphate (mainly hydroxyapatite) and chitosan. Instead of chitosan, poly(diallyldimethylammonium chloride) and polyethylene glycol were also available for microcapsule production by electrospraying. Variations in the electrospraying conditions resulted in a variety of microcapsule shapes. Various types of substrates were successfully encapsulated in microcapsules with a high encapsulation efficiency (more than 80%). Finally, we succeeded in the encapsulation of living yeast cells in microcapsules, and observed their growth within these microcapsules.

  19. Coupling photochemical reaction detection based on singlet oxygen sensitization to capillary electrochromatography

    PubMed

    Dickson; Odom; Ducheneaux; Murray; Milofsky

    2000-07-15

    Despite the impressive separation efficiency afforded by capillary electrochromatography (CEC), the detection of UV-absorbing compounds following separation in capillary dimensions remains limited by the short path length (5-75 microm) through the column. Moreover, analytes that are poor chromophores present an additional challenge with respect to sensitive detection in CEC. This paper illustrates a new photochemical reaction detection scheme for CEC that takes advantage of the catalytic nature of type II photooxidation reactions. The sensitive detection scheme is selective toward molecules capable of photosensitizing the formation of singlet molecular oxygen (1O2). Following separation by CEC, UV-absorbing analytes promote groundstate 3O2 to an excited state (1O2) which reacts rapidly with tert-butyl-3,4,5-trimethylpyrrolecarboxylate, which is added to the running buffer. Detection is based on the loss of pyrrole. The reaction is catalytic in nature since one analyte molecule may absorb light many times, producing large amounts of 1O2. The detection limit for 9-acetylanthracene, following separation by CEC, is approximately 6 x 10(-9) M (S/N = 3). Optimization of the factors effecting the S/N for four model compounds is discussed.

  20. Detection and quantification of 223Ra uptake in bone metastases of patients with castration resistant prostate carcinoma, with the aim of determining the absorbed dose in the metastases.

    PubMed

    Mínguez, P; Gómez de Iturriaga, A; Fernández, I L; Rodeño, E

    To obtain the necessary acquisition and calibration parameters in order to evaluate the possibility of detecting and quantifying 223 Ra uptake in bone metastases of patients treated for castration resistant prostate carcinoma. Furthermore, in the cases in which the activity can be quantified, to determine the absorbed dose. Acquisitions from a Petri dish filled with 223 Ra were performed in the gamma camera. Monte Carlo simulations were also performed to study the partial volume effect. Formulae to obtain the detection and quantification limits of 223 Ra uptake were applied to planar images of two patients 7 days post-administration of 55kBq/kg of 223 Ra. In order to locate the lesions in advance, whole-body scans and SPECT/CT images were acquired after injecting 99m Tc-HDP. The optimal energy window was found to be at 82keV with a medium-energy collimator MEGP. Of the lesions found in the patients, only those that had been detected in both the AP and PA projections could be quantified. These lesions were those which had shown a higher 99m Tc-HDP uptake. The estimated values of absorbed doses ranged between 0.7Gy and 7.8Gy. Of the lesions that can be detected, it is not possible to quantify the activity uptake in some of them, which means that the absorbed dose cannot be determined either. This does not mean that the absorbed dose in these lesions can be regarded as negligible. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  1. MOCCA: A 4k-Pixel Molecule Camera for the Position- and Energy-Resolving Detection of Neutral Molecule Fragments at CSR

    NASA Astrophysics Data System (ADS)

    Gamer, L.; Schulz, D.; Enss, C.; Fleischmann, A.; Gastaldo, L.; Kempf, S.; Krantz, C.; Novotný, O.; Schwalm, D.; Wolf, A.

    2016-08-01

    We present the design of MOCCA, a large-area particle detector that is developed for the position- and energy-resolving detection of neutral molecule fragments produced in electron-ion interactions at the Cryogenic Storage Ring at the Max Planck Institute for Nuclear Physics in Heidelberg. The detector is based on metallic magnetic calorimeters and consists of 4096 particle absorbers covering a total detection area of 44.8 mathrm {mm} × 44.8 mathrm {mm}. Groups of four absorbers are thermally coupled to a common paramagnetic temperature sensor where the strength of the thermal link is different for each absorber. This allows attributing a detector event within this group to the corresponding absorber by discriminating the signal rise times. A novel readout scheme further allows reading out all 1024 temperature sensors that are arranged in a 32 × 32 square array using only 16+16 current-sensing superconducting quantum interference devices. Numerical calculations taking into account a simplified detector model predict an energy resolution of Δ E_mathrm {FWHM} le 80 mathrm {eV} for all pixels of this detector.

  2. Increasing Protein Charge State When Using Laser Electrospray Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Karki, Santosh; Flanigan, Paul M.; Perez, Johnny J.; Archer, Jieutonne J.; Levis, Robert J.

    2015-05-01

    Femtosecond (fs) laser vaporization is used to transfer cytochrome c, myoglobin, lysozyme, and ubiquitin from the condensed phase into an electrospray (ES) plume consisting of a mixture of a supercharging reagent, m-nitrobenzyl alcohol ( m-NBA), and trifluoroacetic acid (TFA), acetic acid (AA), or formic acid (FA). Interaction of acid-sensitive proteins like cytochrome c and myoglobin with the highly charged ES droplets resulted in a shift to higher charge states in comparison with acid-stable proteins like lysozyme and ubiquitin. Laser electrospray mass spectrometry (LEMS) measurements showed an increase in both the average charge states (Zavg) and the charge state with maximum intensity (Zmode) for acid-sensitive proteins compared with conventional electrospray ionization mass spectrometry (ESI-MS) under equivalent solvent conditions. A marked increase in ion abundance of higher charge states was observed for LEMS in comparison with conventional electrospray for cytochrome c (ranging from 19+ to 21+ versus 13+ to 16+) and myoglobin (ranging from 19+ to 26+ versus 18+ to 21+) using an ES solution containing m-NBA and TFA. LEMS measurements as a function of electrospray flow rate yielded increasing charge states with decreasing flow rates for cytochrome c and myoglobin.

  3. Electrospray methodologies for characterization and deposition of nanoparticles

    NASA Astrophysics Data System (ADS)

    Modesto Lopez, Luis Balam

    Electrospray is an aerosolization method that generates highly charged droplets from solutions or suspensions and, after a series of solvent evaporation -- droplet fission cycles, it results in particles carrying multiple charges. Highly charged particles are used in a variety of applications, including particle characterization, thin film deposition, nanopatterning, and inhalation studies among several others. In this work, a soft X-ray photoionization was coupled with an electrospray to obtain monodisperse, singly charged nanoparticles for applications in online size characterization with electrical mobility analysis. Photoionization with the soft X-ray charger enhanced the diffusion neutralization rate of the highly charged bacteriophages, proteins, and solid particles. The effect of nanoparticle surface charge and nanoparticle agglomeration in liquids on the electrospray process was studied experimentally and a modified expression to calculate the effective electrical conductivity of nanosuspensions was proposed. The effective electrical conductivity of TiO2 nanoparticle suspensions is strongly dependent on the electrical double layer and the agglomeration dynamics of the particles; and such dependence is more remarkable in liquids with low ionic strength. TiO2 nanoparticle agglomerates with nearly monodisperse sizes in the nanometer and submicrometer ranges were generated, by electrospraying suspensions with tuned effective electrical conductivity, and used to deposit photocatalytic films for water-splitting. Nanostructured films of iron oxide with uniform distribution of particles over the entire deposition area were formed with an electrospray system. The micro-Raman spectra of the iron oxide films showed that transverse and longitudinal optical modes are highly sensitive to the crystallize size of the electrospray-deposited films. The fabrication of films of natural light-harvesting complexes, with the aim of designing biohybrid photovoltaic devices, was explored with an electrospray. The ability to charge chlorosomes with large number of charges allowed their ballistic deposition onto TiO2 nanostructured columnar films simultaneously maintaining their light-harvesting properties. Single units of natural light-harvesting complexes were isolated in charged electrospray droplets for subsequent size characterization. The charge distribution of natural light-harvesting complexes, aerosolized with a collision nebulizer, was determined with tandem differential mobility analysis. It was found that nebulized light-harvesting complexes were multiply charged; hence they have potential applications in the deposition of functional films using electric fields. The studies conducted as part of this dissertation addressed fundamental issues in the characterization and deposition of nanoparticle suspensions and elucidated applications of the electrospray technique, particularly for solar energy utilization.

  4. The use of PCR/Electrospray Ionization-Time-of-Flight-Mass Spectrometry (PCR/ESI-TOF-MS) to detect bacterial and fungal colonization in healthy military service members.

    PubMed

    Vetor, Ryan; Murray, Clinton K; Mende, Katrin; Melton-Kreft, Rachel; Akers, Kevin S; Wenke, Joseph; Spirk, Tracy; Guymon, Charles; Zera, Wendy; Beckius, Miriam L; Schnaubelt, Elizabeth R; Ehrlich, Garth; Vento, Todd J

    2016-07-22

    The role of microbial colonization in disease is complex. Novel molecular tools to detect colonization offer theoretical improvements over traditional methods. We evaluated PCR/Electrospray Ionization-Time-of-Flight-Mass Spectrometry (PCR/ESI-TOF-MS) as a screening tool to study colonization of healthy military service members. We assessed 101 healthy Soldiers using PCR/ESI-TOF-MS on nares, oropharynx, and groin specimens for the presence of gram-positive and gram-negative bacteria (GNB), fungi, and antibiotic resistance genes. A second set of swabs was processed by traditional culture, followed by identification using the BD Phoenix automated system; comparison between PCR/ESI-TOF-MS and culture was carried out only for GNB. Using PCR/ESI-TOF-MS, at least one colonizing organism was found on each individual: mean (SD) number of organisms per subject of 11.8(2.8). The mean number of organisms in the nares, groin and oropharynx was 3.8(1.3), 3.8(1.4) and 4.2(2), respectively. The most commonly detected organisms were aerobic gram-positive bacteria: primarily coagulase-negative Staphylococcus (101 subjects: 341 organisms), Streptococcus pneumoniae (54 subjects: 57 organisms), Staphylococcus aureus (58 subjects: 80 organisms) and Nocardia asteroides (45 subjects: 50 organisms). The mecA gene was found in 96 subjects. The most commonly found GNB was Haemophilus influenzae (20 subjects: 21 organisms) and the most common anaerobe was Propionibacterium acnes (59 subjects). Saccharomyces species (30 subjects) were the most common fungi detected. Only one GNB (nares E. coli) was identified in the same subject by both diagnostic systems. PCR/ESI-TOF-MS detected common colonizing organisms and identified more typically-virulent bacteria in asymptomatic, healthy adults. PCR/ESI-TOF-MS appears to be a useful method for detecting bacterial and fungal organisms, but further clinical correlation and validation studies are needed.

  5. Selective and sensitive detection of chromium(VI) in waters using electrospray ionization mass spectrometry.

    PubMed

    Weldy, Effie; Wolff, Chloe; Miao, Zhixin; Chen, Hao

    2013-09-01

    From 2000 through 2011, there were 14 criminal cases of violations of the Clean Water Act involving the discharge of chromium, a toxic heavy metal, into drinking and surface water sources. As chromium(VI), a potential carcinogen present in the environment, represents a significant safety concern, it is currently the subject of an EPA health risk assessment. Therefore, sensitive and selective detection of this species is highly desired. This study reports the analysis of chromium(VI) in water samples by electrospray ionization mass spectrometry (ESI-MS) following its reduction and complexation with ammonium pyrrolidinedithiocarbamate (APDC). The reduction and subsequent complexation produce a characteristic [Cr(III)O]-PDC complex which can be detected as a protonated ion of m/z 507 in the positive ion mode. The detection is selective to chromium(VI) under acidic pH, even in the presence of chromium(III) and other metal ions, providing high specificity. Different water samples were examined, including deionized, tap, and river waters, and sensitive detection was achieved. In the case of deionized water, quantification over the concentration range of 3.7 to 148ppb gave an excellent correlation coefficient of 0.9904 using the enhanced MS mode scan. Using the single-reaction monitoring (SRM) mode (monitoring the characteristic fragmentation of m/z 507 to m/z 360), the limit of detection (LOD) was found to be 0.25ppb. The LOD of chromium(VI) for both tap and river water samples was determined to be 2.0ppb. A preconcentration strategy using simple vacuum evaporation of the aqueous sample was shown to further improve the ESI signal by 15 fold. This method, with high sensitivity and selectivity, should provide a timely solution for the real-world analysis of toxic chromium(VI). Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  6. Quantitative determination of metformin, saxagliptin and 5-hydroxy saxagliptin simultaneously by hydrophilic interaction liquid chromatography - electrospray ionization mass spectrometry and its application to a bioequivalence study with a single-pill combination in human.

    PubMed

    Peng, Ying; Chang, Qingqing; Yang, Na; Gu, Shiyin; Zhou, Yi; Yin, Lifang; Aa, Jiye; Wang, Guangji; Sun, Jianguo

    2018-04-01

    A simple, sensitive and specific hydrophilic interaction liquid chromatography coupled to electrospray ionization mass spectrometric (HILIC-MS) method was developed and validated to determine the plasma concentrations of metformin, saxagliptin and 5-hydroxy saxagliptin simultaneously in clinical studies. Plasma samples were first acidified and then protein precipitated with acetonitrile. Chromatographic separation was achieved on a HILIC Chrom Matrix HP amide column (5 μm, 3.0 × 100 mm I.D.). The mobile phase consisted of acetonitrile and 5 mM ammonium formate buffer containing 0.1% formic acid. Multiple reaction monitoring transitions were performed on triple quadrupole mass spectrometric detection in positive-ion mode with an electrospray ionization source. The calibration curves showed good linearity (r ≥ 0.999) over the established concentration range of 1.0-1000 ng/mL for metformin and 0.1-100 ng/mL for saxagliptin and its active metabolite 5-hydroxy saxagliptin. The extraction recovery for all of the analytes was >92% and the matrix effect ranged from 91.0 to 110.0%. After validation, the method was successfully applied to a bioequivalence study with a single-pill combination (SPC) consisting of 5 mg saxagliptin and 500 mg metformin in 10 healthy Chinese subjects. Copyright © 2018. Published by Elsevier B.V.

  7. [Direct determination of ethyl carbamate in Chinese rice wine and grape wine by ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry].

    PubMed

    Wang, Lijuan; Ke, Runhui; Wang, Bing; Yin, Jianjun; Song, Quanhou

    2012-09-01

    An ultra performance liquid chromatography-electrospray ionization tandem mass spectrometric (UPLC-ESI-MS/MS) method was established for the direct determination of ethyl carbamate in Chinese rice wine and grape wine. The Chinese rice wine and grape wine samples were diluted with distilled water, filtered through 0. 22 microm microporous membrane. The LC separation was performed on a Waters Acquity UPLC system with a BEH C18 column, acetonitrile and 0. 1% (v/v) acetic acid aqueous solution as the mobile phase. The ethyl carbamate was determined in the mode of electrospray positive ionization (ESI+) and multiple reaction monitoring (MRM). The butyl carbamate (BC) was used as the internal standard for the quantitative determination. The calibration curve showed good linearity in the range of 2 - 500 microg/L with the correlation coefficient greater than 0.995. The limit of detection (LOD) was 1.7 microg/L and the limit of quantification (LOQ) was 5.0 microg/L. The recoveries of the ethyl carbamate in Chinese rice wine and grape wine was in the range of 90% - 102%. The relative standard deviations (RSDs) of intra-day and inter-day determinations were 0. 8% - 4.5% and 1.4% - 5.6% (n = 6). The results indicated that the proposed method is easy, fast, sensitive, and suitable for the determination of ethyl carbamate in Chinese rice wine and grape wine.

  8. Development of an electrospray-(63)Ni-differential ion mobility spectrometer for the analysis of aqueous samples.

    PubMed

    Kuklya, Andriy; Uteschil, Florian; Kerpen, Klaus; Marks, Robert; Telgheder, Ursula

    2014-03-01

    The feasibility of an electrospray coupled with a (63)Ni-differential ion mobility spectrometer (DMS) for the analysis of water samples was proven on examples of 2-hexanone, fluoroacetamide, l-nicotine and 1-phenyl-2-thiourea water solutions. The model substances were selected in order to cover the vapor pressure range of 0.3-1467 Pa. To reduce the inline humidity, which demonstrates a strong influence on the analyte compensation voltage, two units with a desolvation region lengths of 15.5 and 7 mm were examined. The counter gas (heated to 100 °C nitrogen) with flow rates of 100 mL min(-1) and 30 mL min(-1) for short and long desolvation units, respectively, was essential for the efficient reduction of humidity. The reduction of water content in the carrier gas to 2.2-2.4 g m(-3) and to 1.8-2.0 g m(-3) for the short and long desolvation unit, respectively, was achieved at an electrospray flow rate of 1000 nL min(-1). With this adjusted experimental setup, the detection of model substances in the water solutions, in the range of 0.1-50 mg L(-1), was performed. No correlation between the vapor pressure and signal area was observed. The high stability of the inline humidity, and the correspondingly stable carrier gas flow rate, were found to be essential for an acceptable reproducibility. © 2013 Elsevier B.V. All rights reserved.

  9. Prediction Metrics for Chemical Detection in Long-Wave Infrared Hyperspectral Imagery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chilton, Marie C.; Walsh, Stephen J.; Daly, Don S.

    2009-01-29

    A natural or anthropogenic process often generates a signature gas plume whose chemical constituents may be identified using hyperspectral imagery. A hyperspectral image is a pixel-indexed set of spectra where each spectrum reflects the chemical constituents of the plume, the atmosphere, the bounding background surface, and instrument noise. This study explored the relationship between gas absorbance and background emissivity across the long-wave infrared (LWIR) spectrum and how they affect relative gas detection sensitivity. The physics-based model for the observed radiance shows that high gas absorbance coupled with low background emissivity at a single wavenumber results in a stronger recorded radiance.more » Two sensitivity measures were developed to predict relative probability of detection using chemical absorbance and background emissivity: one focused on a single wavenumber while another accounted for the entire spectrum. The predictive abilities of these measures were compared to synthetic image analysis. This study simulated images with 499 distinct gases at each of 6 concentrations over 6 different background surfaces with the atmosphere and level of instrument noise held constant. The Whitened Matched Filter was used to define gas detection from an image spectrum. The estimate of a chemical’s probability of detection at a given concentration over a specific background was the proportion of detections in 500 trials. Of the 499 chemicals used in the images, 276 had estimated probabilities of detection below 0.2 across all backgrounds and concentrations; these chemicals were removed from the study. For 92.8 percent of the remaining chemicals, the single channel measure correctly predicted the background over which the chemical had the largest relative probability of detection. Further, the measure which accounted for information across all wavenumbers predicted the background over which the chemical had the largest relative probability of detection for 93.3 percent of the chemicals. These results suggest that the wavenumber with largest gas absorbance has the most influence over gas detection for this data. By furthering the in-silico experimentation with higher concentrations of gases not detectable in this experiment or by standardizing the gas absorbance spectra to unit vectors, these conclusions may be confirmed and generalized to more gases. This will help simplify image acquisition planning and the identification of unknowns in field collected images.« less

  10. High-Resolution Metabolomics Assessment of Military Personnel: Evaluating Analytical Strategies for Chemical Detection.

    PubMed

    Liu, Ken H; Walker, Douglas I; Uppal, Karan; Tran, ViLinh; Rohrbeck, Patricia; Mallon, Timothy M; Jones, Dean P

    2016-08-01

    The aim of this study was to maximize detection of serum metabolites with high-resolution metabolomics (HRM). Department of Defense Serum Repository (DoDSR) samples were analyzed using ultrahigh resolution mass spectrometry with three complementary chromatographic phases and four ionization modes. Chemical coverage was evaluated by number of ions detected and accurate mass matches to a human metabolomics database. Individual HRM platforms provided accurate mass matches for up to 58% of the KEGG metabolite database. Combining two analytical methods increased matches to 72% and included metabolites in most major human metabolic pathways and chemical classes. Detection and feature quality varied by analytical configuration. Dual chromatography HRM with positive and negative electrospray ionization provides an effective generalized method for metabolic assessment of military personnel.

  11. High-resolution metabolomics assessment of military personnel: Evaluating analytical strategies for chemical detection

    PubMed Central

    Liu, Ken H.; Walker, Douglas I.; Uppal, Karan; Tran, ViLinh; Rohrbeck, Patricia; Mallon, Timothy M.; Jones, Dean P.

    2016-01-01

    Objective To maximize detection of serum metabolites with high-resolution metabolomics (HRM). Methods Department of Defense Serum Repository (DoDSR) samples were analyzed using ultra-high resolution mass spectrometry with three complementary chromatographic phases and four ionization modes. Chemical coverage was evaluated by number of ions detected and accurate mass matches to a human metabolomics database. Results Individual HRM platforms provided accurate mass matches for up to 58% of the KEGG metabolite database. Combining two analytical methods increased matches to 72%, and included metabolites in most major human metabolic pathways and chemical classes. Detection and feature quality varied by analytical configuration. Conclusions Dual chromatography HRM with positive and negative electrospray ionization provides an effective generalized method for metabolic assessment of military personnel. PMID:27501105

  12. Identification of novel disulfide adducts between the thiol containing leaving group of the nerve agent VX and cysteine containing tripeptides derived from human serum albumin.

    PubMed

    Kranawetvogl, Andreas; Küppers, Jim; Gütschow, Michael; Worek, Franz; Thiermann, Horst; Elsinghorst, Paul W; John, Harald

    2017-08-01

    Chemical warfare agents represent a continuous and considerable threat to military personnel and the civilian population. Such compounds are prohibited by the Chemical Weapons Convention, to which adherence by the member states is strictly controlled. Therefore, reliable analytical methods for verification of an alleged use of banned substances are required. Accordingly, current research focuses on long-term biomarkers derived from covalent adducts with biomolecules such as proteins. Recently, we have introduced a microbore liquid chromatography/electrospray ionization high-resolution tandem mass spectrometry method allowing for the investigation of two different classes of adducts of the nerve agent VX with human serum albumin (HSA). Phosphonylated tyrosine residues and novel disulfide adducts at cysteine residues of HSA were produced by enzymatic cleavage with pronase and detected simultaneously. Notably, the thiol containing leaving group of VX (2-(diisopropylamino)ethanethiol, DPAET) formed disulfide adducts that were released as cysteine and proline containing dipeptides originating from at least two different sites of HSA. Aim of this study was to identify assumed and novel adducts of DPAET with HSA using synthetic peptide reference compounds. Two novel tripeptides were identified representing disulfide adducts with DPAET (Met-Pro-Cys-DPAET, MPC-DPAET and Asp-Ile-Cys-DPAET, DIC-DPAET). MPC-DPAET was shown to undergo partial in-source decay during electrospray ionization for MS detection thereby losing the N-terminal Met residue. This results in the more stable Pro-Cys-DPAET (PC-DPAET) dipeptide detectable as protonated ion. The limit of detection for MPC-DPAET was evaluated, revealing toxicologically relevant VX plasma concentrations. The results provide novel insights into the reactivity of VX and its endogenous targets. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Quantitative Detection of Trace Malachite Green in Aquiculture Water Samples by Extractive Electrospray Ionization Mass Spectrometry

    PubMed Central

    Fang, Xiaowei; Yang, Shuiping; Chingin, Konstantin; Zhu, Liang; Zhang, Xinglei; Zhou, Zhiquan; Zhao, Zhanfeng

    2016-01-01

    Exposure to malachite green (MG) may pose great health risks to humans; thus, it is of prime importance to develop fast and robust methods to quantitatively screen the presence of malachite green in water. Herein the application of extractive electrospray ionization mass spectrometry (EESI-MS) has been extended to the trace detection of MG within lake water and aquiculture water, due to the intensive use of MG as a biocide in fisheries. This method has the advantage of obviating offline liquid-liquid extraction or tedious matrix separation prior to the measurement of malachite green in native aqueous medium. The experimental results indicate that the extrapolated detection limit for MG was ~3.8 μg·L−1 (S/N = 3) in lake water samples and ~0.5 μg·L−1 in ultrapure water under optimized experimental conditions. The signal intensity of MG showed good linearity over the concentration range of 10–1000 μg·L−1. Measurement of practical water samples fortified with MG at 0.01, 0.1 and 1.0 mg·L−1 gave a good validation of the established calibration curve. The average recoveries and relative standard deviation (RSD) of malachite green in lake water and Carassius carassius fish farm effluent water were 115% (6.64% RSD), 85.4% (9.17% RSD) and 96.0% (7.44% RSD), respectively. Overall, the established EESI-MS/MS method has been demonstrated suitable for sensitive and rapid (<2 min per sample) quantitative detection of malachite green in various aqueous media, indicating its potential for online real-time monitoring of real life samples. PMID:27529262

  14. Quantitative Detection of Trace Malachite Green in Aquiculture Water Samples by Extractive Electrospray Ionization Mass Spectrometry.

    PubMed

    Fang, Xiaowei; Yang, Shuiping; Chingin, Konstantin; Zhu, Liang; Zhang, Xinglei; Zhou, Zhiquan; Zhao, Zhanfeng

    2016-08-11

    Exposure to malachite green (MG) may pose great health risks to humans; thus, it is of prime importance to develop fast and robust methods to quantitatively screen the presence of malachite green in water. Herein the application of extractive electrospray ionization mass spectrometry (EESI-MS) has been extended to the trace detection of MG within lake water and aquiculture water, due to the intensive use of MG as a biocide in fisheries. This method has the advantage of obviating offline liquid-liquid extraction or tedious matrix separation prior to the measurement of malachite green in native aqueous medium. The experimental results indicate that the extrapolated detection limit for MG was ~3.8 μg·L(-1) (S/N = 3) in lake water samples and ~0.5 μg·L(-1) in ultrapure water under optimized experimental conditions. The signal intensity of MG showed good linearity over the concentration range of 10-1000 μg·L(-1). Measurement of practical water samples fortified with MG at 0.01, 0.1 and 1.0 mg·L(-1) gave a good validation of the established calibration curve. The average recoveries and relative standard deviation (RSD) of malachite green in lake water and Carassius carassius fish farm effluent water were 115% (6.64% RSD), 85.4% (9.17% RSD) and 96.0% (7.44% RSD), respectively. Overall, the established EESI-MS/MS method has been demonstrated suitable for sensitive and rapid (<2 min per sample) quantitative detection of malachite green in various aqueous media, indicating its potential for online real-time monitoring of real life samples.

  15. Characterisation of Bacteria by Matrix- assisted Laser Desorption/Ionisation and Electrospray Mass Spectrometry.

    DTIC Science & Technology

    1999-12-01

    pesticides trapping and preconcentration column technology developed for water analysis [132]. The SP and SPIA approach seem amenable to the characteri...American Chemical Society, Washington, DC, pp. 62-84. [14] Voorhees, K.J.; Basile , F.; Beverly, M.B.; Abbashawks, C; Hendricker, A.; Cody, R.B. and...134. [15] Basile , F.; Beverly, M.B.; Voorhees, K.J. and Hadfield, T.L. (1998), Pathogenic Bacteria: Their Detection and Differentiation by Rapid

  16. Evaluation of Nobuto filter paper strips for the detection of avian influenza virus antibody in waterfowl

    USGS Publications Warehouse

    Dusek, Robert J.; Hall, Jeffrey S.; Nashold, Sean W.; Teslaa, Joshua L.; Ip, Hon S.

    2011-01-01

    The utility of using Nobuto paper strips for the detection of avian influenza antibodies was examined in mallards (Anas platyrhynchos) experimentally infected with low pathogenic avian influenza viruses. Blood was collected 2 wk after infection and was preserved either as serum or whole blood absorbed onto Nobuto strips. Analysis of samples using a commercially available blocking enzyme-linked immunosorbent assay revealed comparable results (???96% sensitivity for all methods) between sera stored at -30 C and the Nobuto strip preservation method even when the Nobuto strips were stored up to 3 mo at room temperature (RT). Significant differences were detected in the ratio of sample absorbance to negative control absorbance for Nobuto strips stored at RT compared with sera stored at -30 C, although these differences did not affect the ability of the test to reliably detect positive and negative samples. Nobuto strips are a convenient and sensitive alternative to the collection of serum samples when maintaining appropriate storage temperatures is difficult. ?? 2011 American Association of Avian Pathologists.

  17. NEGATIVE ION ELECTROSPRAY OF BROMO- AND CHLORACETIC ACIDS AND AN EVALUATION OF EXACT MASS MEASUREMENTS WITH A BENCH-TOP TIME-OF-FLIGHT MASS SPECTROMETER

    EPA Science Inventory

    The negative ion electrospray mass spectra of six bromo- and chloroacetic acids were measured using two different electrospray interfaces and single quadrupole and bench-top time-of-flight mass spectrometers. With each acid at 50 ug/mL in aqueous methanol at pH 10, the anions ob...

  18. Chrysin and its phosphate ester inhibit cell proliferation and induce apoptosis in Hela cells.

    PubMed

    Zhang, Ting; Chen, Xiaolan; Qu, Lingbo; Wu, Jinglan; Cui, Ran; Zhao, Yufen

    2004-12-01

    To improve the biological activities of chrysin (CR), we synthesize Diethyl Chysin-7-yl phosphate (CPE: C(19)H(19)O(7)P) and tetraethyl bis-phosphoric ester of chrysin (CP: C(23)H(28)O(10)P(2)) through a simplified Atheron-Todd reaction. The interactions of the CR and CPE with lysozyme were explored by electrospray ionization mass spectrometry (ESI) and fluorescence spectrometry method. Experimental results indicate that CPE could form the noncovalent compound with lysozyme, while the interaction of the CR with lysozyme was not detected. In addition, whether and how the compounds CPE and CP affect proliferation and apoptosis in human cervical cancer Hela cells were investigated. Moreover, the effects of CPE and CP in Hela cells were compared with that of the nonmodified CR compound. The Hela cells were co-cultured with CR, CP, and CPE as experimental groups, respectively, and corresponding control groups treated without CR, CP, and CPE. The proliferation and apoptosis were detected using MTT assay, HCl denatured-methyl green-pyronin staining, PCNA immunohistochemistry and TUNEL techniques. The cell growth IC(50), relative absorbance (RA), proliferating index (PI), PCNA-IR (immunoreactivity IR) integration value (IV), and apoptosis index (AI) were calculated and their correlation was analyzed in each group. The results show that all CR, CP, and CPE could inhibit proliferation and induce apoptosis in Hela cells. Moreover, the effects of CP and CPE were more potent than that of CR. The CP and CPE were proved to be a kind of stronger apoptosis inducers than nonphosphated CR. There was a negative correlation between proliferation and apoptosis. In conclusion, the CR, CP, and CPE could effectively inhibit growth by down-regulated expression of PCNA, and induce apoptosis in Hela cells. The efficiency of the modified CP and CPE preceded nonmodified CR compounds. The CP and CPE may be a new potential anti-cancer drug for therapy of human cervical carcinoma.

  19. Design of a five-band terahertz perfect metamaterial absorber using two resonators

    NASA Astrophysics Data System (ADS)

    Meng, Tianhua; Hu, Dan; Zhu, Qiaofen

    2018-05-01

    We present a polarization-insensitive five-band terahertz perfect metamaterial absorber composed of two metallic circular rings and a metallic ground film separated by a dielectric layer. The calculated results show that the absorber has five distinctive absorption bands whose peaks are greater than 99% on average. The physical origin of the absorber originates from the combination of dipolar, hexapolar, and surface plasmon resonance of the patterned metallic structure, which is different from the work mechanism of previously reported absorbers. In addition, the influence of the structural parameters on the absorption spectra is analyzed to further confirm the origin of the five-band absorption peaks. The proposed absorber has potential applications in terahertz imaging, refractive index sensing, and material detecting.

  20. Sensitivity of electrospray molecular dynamics simulations to long-range Coulomb interaction models

    NASA Astrophysics Data System (ADS)

    Mehta, Neil A.; Levin, Deborah A.

    2018-03-01

    Molecular dynamics (MD) electrospray simulations of 1-ethyl-3-methylimidazolium tetrafluoroborate (EMIM-BF4) ion liquid were performed with the goal of evaluating the influence of long-range Coulomb models on ion emission characteristics. The direct Coulomb (DC), shifted force Coulomb sum (SFCS), and particle-particle particle-mesh (PPPM) long-range Coulomb models were considered in this work. The DC method with a sufficiently large cutoff radius was found to be the most accurate approach for modeling electrosprays, but, it is computationally expensive. The Coulomb potential energy modeled by the DC method in combination with the radial electric fields were found to be necessary to generate the Taylor cone. The differences observed between the SFCS and the DC in terms of predicting the total ion emission suggest that the former should not be used in MD electrospray simulations. Furthermore, the common assumption of domain periodicity was observed to be detrimental to the accuracy of the capillary-based electrospray simulations.

  1. Electrospray-assisted drying of live probiotics in acacia gum microparticles matrix.

    PubMed

    Zaeim, Davood; Sarabi-Jamab, Mahboobe; Ghorani, Behrouz; Kadkhodaee, Rassoul; Tromp, R Hans

    2018-03-01

    Acacia gum solution was employed as a carrier for electrospray-assisted drying of probiotic cells. To optimize the process, effect of gum concentration, thermal sterilization as a prerequisite for microbial studies, and surfactant addition on physical properties of feed solution was investigated. Increasing gum concentration from 20 to 40 wt.% led to a viscosity increase, whilst surface tension did not change meaningfully and electrical conductivity declined after an increasing trend up to 30 wt.% of the gum. Thermal sterilization increased the viscosity without any significant effect on the conductivity and surface tension. Surfactant addition reduced the surface tension and conductivity but the viscosity increased. Highly uniform particles were formed by electrospray-assisted drying of autoclaved 35 wt.% acacia gum solution containing 1 wt.% Tween 80. Thermal sterilization and surfactant addition improved electrospray-ability of acacia gum solution. Bacterial count showed that more than 96 percent of probiotic cells passed the process viably. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Sensitivity of electrospray molecular dynamics simulations to long-range Coulomb interaction models.

    PubMed

    Mehta, Neil A; Levin, Deborah A

    2018-03-01

    Molecular dynamics (MD) electrospray simulations of 1-ethyl-3-methylimidazolium tetrafluoroborate (EMIM-BF_{4}) ion liquid were performed with the goal of evaluating the influence of long-range Coulomb models on ion emission characteristics. The direct Coulomb (DC), shifted force Coulomb sum (SFCS), and particle-particle particle-mesh (PPPM) long-range Coulomb models were considered in this work. The DC method with a sufficiently large cutoff radius was found to be the most accurate approach for modeling electrosprays, but, it is computationally expensive. The Coulomb potential energy modeled by the DC method in combination with the radial electric fields were found to be necessary to generate the Taylor cone. The differences observed between the SFCS and the DC in terms of predicting the total ion emission suggest that the former should not be used in MD electrospray simulations. Furthermore, the common assumption of domain periodicity was observed to be detrimental to the accuracy of the capillary-based electrospray simulations.

  3. Controlled Electrospray Generation of Nonspherical Alginate Microparticles.

    PubMed

    Jeyhani, Morteza; Mak, Sze Yi; Sammut, Stephen; Shum, Ho Cheung; Hwang, Dae Kun; Tsai, Scott S H

    2017-12-11

    Electrospraying is a technique used to generate microparticles in a high throughput manner. For biomedical applications, a biocompatible electrosprayed material is often desirable. Using polymers, such as alginate hydrogels, makes it possible to create biocompatible and biodegradable microparticles that can be used for cell encapsulation, to be employed as drug carriers, and for use in 3D cell culturing. Evidence in the literature suggests that the morphology of the biocompatible microparticles is relevant in controlling the dynamics of the microparticles in drug delivery and 3D cell culturing applications. Yet, most electrospray-based techniques only form spherical microparticles, and there is currently no widely adopted technique for producing nonspherical microparticles at a high throughput. Here, we demonstrate the generation of nonspherical biocompatible alginate microparticles by electrospraying, and control the shape of the microparticles by varying experimental parameters such as chemical concentration and the distance between the electrospray tip and the particle-solidification bath. Importantly, we show that these changes to the experimental setup enable the synthesis of different shaped particles, and the systematic change in parameters, such as chemical concentration, result in monotonic changes to the particle aspect ratio. We expect that these results will find utility in many biomedical applications that require biocompatible microparticles of specific shapes. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Development of a conductivity-based photothermal absorbance detection microchip using polyelectrolytic gel electrodes.

    PubMed

    Chun, Honggu; Dennis, Patty J; Ferguson Welch, Erin R; Alarie, Jean Pierre; Jorgenson, James W; Ramsey, J Michael

    2017-11-10

    The development and application of polyelectrolytic gel electrodes (PGEs) for a microfluidic photothermal absorbance detection system is described. The PGEs are used to measure changes in conductivity based on heat generation by analytes absorbing light and changing the solution viscosity. The PGEs are suitable for direct contact conductivity measurements since they do not degrade with exposure to high electric fields. Both a 2-electrode system with DC voltages and a 3-electrode system with AC voltages were investigated. Experimental factors including excitation voltage, excitation frequency, laser modulation frequency, laser power, and path length were tested. The limits of detection for the 3-electrode and 2-electrode systems are 500nM and 0.55nM for DABSYL-tagged glucosamine, respectively. In addition, an electrokinetic separation of a potassium, DABSYL-tagged glucosamine, Rhodamine 6G, and Rhodamine B mixture was demonstrated. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Carbon- and oxygen-free Cu(InGa)(SSe)₂ solar cell with a 4.63% conversion efficiency by electrostatic spray deposition.

    PubMed

    Yoon, Hyun; Na, Seung Heon; Choi, Jae Young; Kim, Min Woo; Kim, Hayong; An, Hee Sang; Min, Byoung Koun; Ahn, SeJin; Yun, Jae Ho; Gwak, Jihye; Yoon, KyungHoon; Kolekar, Sanjay S; van Hest, Maikel F A M; Al-Deyab, Salem S; Swihart, Mark T; Yoon, Sam S

    2014-06-11

    We have demonstrated the first example of carbon- and oxygen-free Cu(In,Ga)(SSe)2 (CIGSSe) absorber layers prepared by electrospraying a CuInGa (CIG) precursor followed by annealing, sulfurization, and selenization at elevated temperature. X-ray diffraction and scanning electron microscopy showed that the amorphous as-deposited (CIG) precursor film was converted into polycrystalline CIGSSe with a flat-grained morphology after post-treatment. The optimal post-treatment temperature was 300 °C for annealing and 500 °C for both sulfurization and selenization, with a ramp rate of 5 °C/min. The carbon impurities in the precursor film were removed by air annealing, and oxide that was formed during annealing was removed by sulfurization. The fabricated CIGSSe solar cell showed a conversion efficiency of 4.63% for a 0.44 cm(2) area, with Voc = 0.4 V, Jsc = 21 mA/cm(2), and FF = 0.53.

  6. Comprehensive speciation of low-molecular weight selenium metabolites in mustard seeds using HPLC-electrospray linear trap/Orbitrap tandem mass spectrometry.

    PubMed

    Ouerdane, Laurent; Aureli, Federica; Flis, Paulina; Bierla, Katarzyna; Preud'homme, Hugues; Cubadda, Francesco; Szpunar, Joanna

    2013-09-01

    An analytical methodology based on high-resolution high mass accuracy electrospray ionization (ESI) tandem MS assisted by Se-specific detection using inductively coupled plasma mass spectrometry (ICP MS) was developed for speciation of selenium (Se) in seeds of black mustard (Brassica nigra) grown on Se-rich soil. Size-exclusion LC-ICP MS allowed the determination of the Se distribution according to the molecular mass and the control of the species stability during extraction. The optimization of hydrophilic interaction of LC and cation-exchange HPLC resulted in analytical conditions making it possible to detect and characterize over 30 Se species using ESI MS, including a number of minor (<0.5%) metabolites. Selenoglucosinolates were found to be the most important class of species accounting for at least 15% of the total Se present and over 50% of all the metabolites. They were found particularly unstable during aqueous extraction leading to the loss of Se by volatilization as methylselenonitriles and methylselenoisothiocyanates identified using gas chromatography (GC) with the parallel ICP MS and atmospheric pressure chemical ionization (APCI) MS/MS detection. However, selenoglucosinolates could be efficiently recovered by extraction with 70% methanol. Other classes of identified species included selenoamino acids, selenosugars, selenosinapine and selenourea derivatives. The three types of reactions leading to the formation of selenometabolites were: the Se-S substitution in the metabolic pathway, oxidative reactions of -SeH groups with endogenous biomolecules, and chemical reactions, e.g., esterification, of Se-containing molecules and other biomolecules through functional groups not involving Se.

  7. Surfactant-free microemulsion electrokinetic chromatography (SF-MEEKC) with UV and MS detection - a novel approach for the separation and ESI-MS detection of neutral compounds.

    PubMed

    Mohorič, Urška; Beutner, Andrea; Krickl, Sebastian; Touraud, Didier; Kunz, Werner; Matysik, Frank-Michael

    2016-12-01

    Microemulsion electrokinetic chromatography (MEEKC) is a powerful tool to separate neutral species based on differences in their hydrophobic and hydrophilic properties. However, as a major drawback the conventionally used SDS based microemulsions are not compatible with electrospray ionization mass spectrometry (ESI-MS). In this work, a surfactant-free microemulsion (SFME) consisting of water, ethanol, and 1-octanol is used for surfactant-free microemulsion electrokinetic chromatography (SF-MEEKC). Ammonium acetate was added to the SFME enabling electrophoretic separations. The stability of SFMEs containing ammonium acetate was investigated using small-angle X-ray scattering and dynamic light scattering. A method for the separation of a model system of hydrophobic and hydrophilic neutral vitamins, namely the vitamins B 2 and D 3 , and the cationic vitamin B 1 was developed using UV/VIS detection. The influence of the ammonium acetate concentration on the separation performance was studied in detail. The method was characterized concerning reproducibility of migration times and peak areas and concerning the linearity of the calibration data. Furthermore, SF-MEEKC was coupled to ESI-MS investigating the compatibility between SFMEs and the ESI process. The signal intensities of ESI-MS measurements of the model analytes were comparable for SFMEs and aqueous systems. Finally, the vitamin D 3 content of a drug treating vitamin D 3 deficiency was determined by SF-MEEKC coupled to ESI-MS using 25-hydroxycholecalciferol as an internal standard. Graphical abstract The concept of surfactant-free microemulsion electrokinetic chromatography coupled to electrospray ionization mass spectrometry.

  8. Coupling of non-aqueous electrokinetic chromatography using cationic cyclodextrins with electrospray ionization mass spectrometry.

    PubMed

    Mol, Roelof; de Jong, Gerhardus J; Somsen, Govert W

    2008-01-01

    Non-aqueous electrokinetic chromatography (NAEKC) using cationic cyclodextrins (CDs) was coupled to electrospray ionization mass spectrometry (ESI-MS). A methanolic background electrolyte (BGE) was used which contained the hydrochloride salts of the single-isomer derivative cyclodextrins 6-monodeoxy-6-mono(2-hydroxy)propylamino-beta-cyclodextrin (IPA-beta-CD) or 6-monodeoxy-6-mono(3-hydroxy)propylamino-beta-cyclodextrin (PA-beta-CD). Applying a reversed capillary electrophoresis (CE) polarity (-30 kV), efficient separation of negatively charged compounds was achieved with plate numbers of up to 190,000. PA-beta-CD appeared to be the most suitable for the separation of various acidic drugs while also providing a high chiral selectivity. Analyte detection was achieved by ESI-MS in the negative-ion mode using a sheath-liquid interface. In order to prevent current drops caused by the cathodic electroosmotic flow, a pressure of 15 mbar was applied on the inlet vial during NAEKC/MS analysis. The effect of the cationic CDs on the MS signal intensities of acidic test drugs was thoroughly studied. When a voltage is applied across the CE capillary, the overall mobility of the cationic CDs is towards the inlet vial so that no CD molecules enter the ion source. The chloride counter ions of the CDs, which migrated towards the capillary outlet, were found to cause ionization suppression, although significant analyte signals could still be detected. Depending on the CD concentration in the BGE, limits of detection for acidic drugs were in the 50-400 ng/mL range in full-scan mode.

  9. Analysis of GAA/TTC DNA triplexes using nuclear magnetic resonance and electrospray ionization mass spectrometry.

    PubMed

    Mariappan, S V Santhana; Cheng, Xun; van Breemen, Richard B; Silks, Louis A; Gupta, Goutam

    2004-11-15

    The formation of a GAA/TTC DNA triplex has been implicated in Friedreich's ataxia. The destabilization of GAA/TTC DNA triplexes either by pH or by binding to appropriate ligands was analyzed by nuclear magnetic resonance (NMR) and positive-ion electrospray mass spectrometry. The triplexes and duplexes were identified by changes in the NMR chemical shifts of H8, H1, H4, 15N7, and 15N4. The lowest pH at which the duplex is detectable depends upon the overall stability and the relative number of Hoogsteen C composite function G to T composite function A basepairs. A melting pH (pHm) of 7.6 was observed for the destabilization of the (GAA)2T4(TTC)2T4(CTT)2 triplex to the corresponding Watson-Crick duplex and the T4(CTT)2 overhang. The mass spectrometric analyses of (TTC)6.(GAA)6 composite function(TTC)6 triplex detected ions due to both triplex and single-stranded oligonucleotides under acidic conditions. The triplex ions disappeared completely at alkaline pH. Duplex and single strands were detectable only at neutral and alkaline pH values. Mass spectrometric analyses also showed that minor groove-binding ligands berenil, netropsin, and distamycin and the intercalating ligand acridine orange destabilize the (TTC)6.(GAA)6 composite function (TTC)6 triplex. These NMR and mass spectrometric methods may function as screening assays for the discovery of agents that destabilize GAA/TTC triplexes and as general methods for the characterization of structure, dynamics, and stability of DNA and DNA-ligand complexes.

  10. Formation of enriched black tea extract loaded chitosan nanoparticles via electrospraying

    NASA Astrophysics Data System (ADS)

    Hammond, Samuel James

    Creating nanoparticles of beneficial nutraceuticals and pharmaceuticals has had a large surge of research due to the enhancement of absorption and bioavailability by decreasing their size. One of these ways is by electrohydrodynamic atomization, also known as electrospraying. In general, this novel process is done by forcing a liquid through a capillary nozzle and which is subjected to an electrical field. While there are different ways to create nanoparticles, the novel method of electrospraying can be beneficial over other types of nanoparticle formation. Reasons include high control over particle size and distribution by altering electrospray parameters (voltage, flow rate, distance, and time), higher encapsulation efficiency than other methods, and also it is a one step process without exposure to extreme conditions (Gomez-Estaca et. al. 2012, Jaworek and Sobcyzk 2008). The current study aimed to create a chitosan encapsulated theaflavin-2 enriched black tea extract (BTE) nanoparticles via electrospraying. The first step of this process was to create the smallest chitosan nanoparticles possible by altering the electrospray parameters and the chitosan-acetic acid solution parameters. The solution properties altered include chitosan molecular weight, acetic acid concentration, and chitosan concentration. Specifically, the electrospray parameters such as voltage, flow rate and distance from syringe to collector are the most important in determining particle size. After creating the smallest chitosan particles, the TF-2 enriched black tea extract was added to the chitosan-acetic acid solution to be electrosprayed. The particles were assessed with the following procedures: Atomic force microscopy (AFM) and scanning electron microscopy (SEM) for particle morphology and size, and loading efficiency with ultraviolet--visible spectrophotometer (UV-VIS). Chitosan-BTE nanoparticles were successfully created in a one step process. Diameter of the particles on average ranged from 255 nm to 560 nm. Encapsulation efficiency was above 95% for all but one sample set. Future work includes MTT assay and cellular uptake.

  11. Characterization of the polyphenolic composition of purple loosestrife (Lythrum salicaria).

    PubMed

    Rauha, J P; Wolfender, J L; Salminen, J P; Pihlaja, K; Hostettmann, K; Vuorela, H

    2001-01-01

    Phenolic compounds of purple loosestrife (Lythrum salicaria L.) were analysed by the use of liquid chromatography-mass spectrometry (LC/MS) equipped with atmospheric pressure chemical ionisation (APCI) and electrospray ionisation (ESI). The presence of vitexin and orientin as well as their isomers, isovitexin and isoorientin, were confirmed using ion trap multiple stage LC/MS3 analysis. Several phenolic acids and tannins were also detected. Ellagitannins, vescalagin and pedunculagin, are reported from the plant for the first time.

  12. Low Level Exposure to Sulfur Mustard: Development of a SOP for Analysis of Albumin Adducts and of a System for Non-Invasive Diagnosis on Skin

    DTIC Science & Technology

    2007-08-01

    of fluorinated amino acid derivatives under Electron Capture Atmospheric Pressure Chemical Ionization (EC APCI) conditions results in far better...Figure 6). Mass spectrometric analyses indicated that at least for the synthetic reference compound, the fluorinated derivative could be determined... fluorinated amino acid derivatives under EC APCI conditions (vide supra) results in far better detection limits, when compared to normal electrospray MS

  13. Polar organic compounds in pore waters of the Chesapeake Bay impact structure, Eyreville core hole: Character of the dissolved organic carbon and comparison with drilling fluids

    USGS Publications Warehouse

    Rostad, C.E.; Sanford, W.E.

    2009-01-01

    Pore waters from the Chesapeake Bay impact structure cores recovered at Eyreville Farm, Northampton County, Virginia, were analyzed to characterize the dissolved organic carbon. After squeezing or centrifuging, a small volume of pore water, 100 ??L, was taken for analysis by electrospray ionization-mass spectrometry. Porewater samples were analyzed directly without filtration or fractionation, in positive and negative mode, for polar organic compounds. Spectra in both modes were dominated by low-molecular-weight ions. Negative mode had clusters of ions differing by -60 daltons, possibly due to increasing concentrations of inorganic salts. The numberaverage molecular weight and weight-average molecular weight values for the pore waters from the Chesapeake Bay impact structure are higher than those reported for other aquatic sources of natural dissolved organic carbon as determined by electrospray ionization-mass spectrometry. In order to address the question of whether drilling mud fluids may have contaminated the pore waters during sample collection, spectra from the pore waters were compared to spectra from drilling mud fluids. Ions indicative of drilling mud fluids were not found in spectra from the pore waters, indicating there was no detectable contamination, and highlighting the usefulness of this analytical technique for detecting potential contamination during sample collection. ?? 2009 The Geological Society of America.

  14. Online reverse phase-high-performance liquid chromatography-fluorescence detection-electrospray ionization-mass spectrometry separation and characterization of heparan sulfate, heparin, and low-molecular weight-heparin disaccharides derivatized with 2-aminoacridone.

    PubMed

    Galeotti, Fabio; Volpi, Nicola

    2011-09-01

    A high-resolution online reverse-phase-high-performance liquid chromatography (RP-HPLC)-fluorescence detector (Fd)-electrospray ionization-mass spectrometry (ESI-MS) separation and structural characterization of disaccharides prepared from heparin (Hep), heparan sulfate (HS), and various low-molecular-weight (LMW)-Hep using heparin lyases and derivatization with 2-aminoacridone (AMAC) are described. A total of 12 commercially available Hep/HS-derived unsaturated disaccharides were separated and unambiguously identified on the basis of their retention times and mass spectra. The constituent disaccharides of various samples, including unfractionated Hep/HS, fast-moving and slow-moving Hep components, and several marketed products, were characterized. Furthermore, for the first time, the saturated trisulfated disaccharide belonging to the nonreducing end of Heps was detected as being approximately 2% in unfractionated samples and ~15-21% in LMW-Heps prepared by nitrous acid depolymerization. No desalting of the commercial products prior to enzymatic digestion or prepurification steps to eliminate any excess of AMAC reagent or interference from proteins, peptides, and other sample impurities before RP-HPLC-Fd-ESI-MS injection were necessary. This method has applicability for the rapid differentiation of pharmaceutical Heps and LMW-Heps prepared by means of different depolymerization processes and for compositional analysis of small amounts of samples derived from biological sources by using the highly sensitive fluorescence detector.

  15. Comparison of different extraction procedures for the comprehensive characterization of bioactive phenolic compounds in Rosmarinus officinalis by reversed-phase high-performance liquid chromatography with diode array detection coupled to electrospray time-of-flight mass spectrometry.

    PubMed

    Borrás Linares, I; Arráez-Román, D; Herrero, M; Ibáñez, E; Segura-Carretero, A; Fernández-Gutiérrez, A

    2011-10-21

    In the present work, a comparative study between two environmentally friendly and selective extraction techniques, such as supercritical fluid extraction (SFE) and pressurized liquid extraction (PLE) have been carried out focusing in the bioactive phenolic compounds present in Rosmarinus officinalis. For the analysis of the SFE and PLE extracts, a new methodology for qualitative characterization has been developed, based on the use of reversed-phase high-performance liquid chromatography (RP-HPLC), equipped with two different detection systems coupled in series: diode array detector (DAD) and time of flight mass spectrometry (TOF-MS) detector connected via an electrospray ionization interface (ESI). The use of a small particle size C(18) column (1.8 μm) provided a great resolution and made possible the separation of several isomers. Moreover, UV-visible spectrophotometry is a valuable tool for identifying the class of phenolic compounds, whereas MS data enabled to structurally characterize the compounds present in the extracts. The applied methodology was useful for the determination of many well-known phenolic compounds present in R. officinalis, such as carnosol, carnosic acid, rosmadial, rosmanol, genkwanin, homoplantaginin, scutellarein, cirsimaritin and rosmarinic acid, as well as other phenolic compounds present in other species belonging to Lamiaceae family. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Use of recombinantly produced 15N3-labelled nicotianamine for fast and sensitive stable isotope dilution ultra-performance liquid chromatography/electrospray ionization time-of-flight mass spectrometry.

    PubMed

    Schmidt, Holger; Böttcher, Christoph; Trampczynska, Aleksandra; Clemens, Stephan

    2011-01-01

    Nicotianamine (NA) is an important metal chelator, implicated in the intra- and intercellular trafficking of several transition metal ions in plants. To decipher its roles in physiological processes such as micronutrient acquisition, distribution or storage, fast and sensitive analytical techniques for quantification of this non-proteinogenic amino acid will be required. The use of a recombinant Schizosaccharomyces pombe strain expressing a nicotianamine synthase (NAS) gene allowed for the production of [(15)N(3)]-NA, which was enriched from cell extracts through cation exchange and used for stable isotope dilution analysis of NA. Such an approach should be widely applicable to important bioanalytes that are difficult to synthesize. The analytical procedure comprises mild aqueous extraction and rapid Fmoc derivatization, followed by fast separation using ultra-performance liquid chromatography (UPLC) and sensitive detection by positive ion electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS) with a chromatographic cycle time of only 8 min. Derivatization was optimized with respect to incubation time and species suitable for quantification. The limit of detection was 0.14 to 0.23 pmol in biological matrices with the response being linear up to 42 pmol. Recovery rates were between 83% and 104% in various biological matrices including fission yeast cells, fungal mycelium, plant leaves and roots.

  17. Ultrafiltration-LC-MS combined with semi-preparative HPLC for the simultaneous screening and isolation of lactate dehydrogenase inhibitors from Belamcanda chinensis.

    PubMed

    Li, Senlin; Li, Sainan; Tang, Ying; Liu, Chunming; Chen, Lina; Zhang, Yuchi

    2016-12-01

    Stroke represents the fourth leading cause of death in the USA and the second leading cause of death worldwide. Lactate dehydrogenase inhibitors are widely used in the treatment of ischemic stroke and natural products are considered a promising source of novel lactate dehydrogenase inhibitors. In this study, we used PC12 cells to determine the protective effect of extracts from the herb Belamcanda chinensis following toxic challenge. Using ultrafiltration high-performance liquid chromatography coupled with photo-diode array detection and electrospray ionization mass spectrometry, we screened and identified isoflavonoids from Belamcanda chinensis extracts. Semi-preparative high-performance liquid chromatography was then applied to separate and isolate the active constituents. Using these methods, we identified six major compounds in Belamcanda chinensis as lactate dehydrogenase inhibitors: tectoridin, iristectorin A, iridin, tectorigenin, irigenin, and irisflorentin, which were then isolated to >92% purity. This is the first report that Belamcanda chinensis extracts contain potent lactate dehydrogenase inhibitors. Our results demonstrate that the systematic isolation of bioactive components from Belamcanda chinensis guided by ultrafiltration high-performance liquid chromatography coupled with photo-diode array detection and electrospray ionization mass spectrometry represents a feasible and efficient technique that could be extended for the identification and isolation of other enzyme inhibitors. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Comparison of electrospray ionization and atmospheric pressure photoionization liquid chromatography mass spectrometry methods for analysis of ergot alkaloids from endophyte-infected sleepygrass (Achnatherum robustum).

    PubMed

    Jarmusch, Alan K; Musso, Ashleigh M; Shymanovich, Tatsiana; Jarmusch, Scott A; Weavil, Miranda J; Lovin, Mary E; Ehrmann, Brandie M; Saari, Susanna; Nichols, David E; Faeth, Stanley H; Cech, Nadja B

    2016-01-05

    Ergot alkaloids are mycotoxins with an array of biological effects. With this study, we investigated for the first time the application of atmospheric pressure photoionization (APPI) as an ionization method for LC-MS analysis of ergot alkaloids, and compared its performance to that of the more established technique of electrospray ionization (ESI). Samples of the grass Achnatherum robustum infected with the ergot producing Epichloë fungus were extracted using cold methanol and subjected to reserved-phase HPLC-ESI-MS and HPLC-APPI-MS analysis. The ergot alkaloids ergonovine and lysergic acid amide were detected in these samples, and quantified via external calibration. Validation parameters were recorded in accordance with ICH guidelines. A triple quadrupole MS operated in multiple reaction monitoring yielded the lowest detection limits. The performance of APPI and ESI methods was comparable. Both methods were subject to very little matrix interference, with percent recoveries ranging from 82% to 100%. As determined with HPLC-APPI-MS quantification, lysergic acid amide and ergonovine were extracted from an A. robustum sample infected with the Epichloë fungus at concentrations of 1.143±0.051 ppm and 0.2822±0.0071 ppm, respectively. There was no statistically significant difference between these concentrations and those determined using ESI for the same samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Qualitative and quantitative analysis of hyaluronan oligosaccharides with high performance thin layer chromatography using reagent-free derivatization on amino-modified silica and electrospray ionization-quadrupole time-of-flight mass spectrometry coupling on normal phase.

    PubMed

    Rothenhöfer, Martin; Scherübl, Rosmarie; Bernhardt, Günther; Heilmann, Jörg; Buschauer, Armin

    2012-07-27

    Purified oligomers of hyalobiuronic acid are indispensable tools to elucidate the physiological and pathophysiological role of hyaluronan degradation by various hyaluronidase isoenzymes. Therefore, we established and validated a novel sensitive, convenient, rapid, and cost-effective high performance thin layer chromatography (HPTLC) method for the qualitative and quantitative analysis of small saturated hyaluronan oligosaccharides consisting of 2-4 hyalobiuronic acid moieties. The use of amino-modified silica as stationary phase allows a simple reagent-free in situ derivatization by heating, resulting in a very low limit of detection (7-19 pmol per band, depending on the analyzed saturated oligosaccharide). By this derivatization procedure for the first time densitometric quantification of the analytes could be performed by HPTLC. The validated method showed a quantification limit of 37-71 pmol per band and was proven to be superior in comparison to conventional detection of hyaluronan oligosaccharides. The analytes were identified by hyphenation of normal phase planar chromatography to mass spectrometry (TLC-MS) using electrospray ionization. As an alternative to sequential techniques such as high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), the validated HPTLC quantification method can easily be automated and is applicable to the analysis of multiple samples in parallel. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Development of high-throughput multi-residue method for non-steroidal anti-inflammatory drugs monitoring in swine muscle by LC-MS/MS.

    PubMed

    Castilhos, Tamara S; Barreto, Fabiano; Meneghini, Leonardo; Bergold, Ana Maria

    2016-07-01

    A reliable and simple method for the detection and quantification of residues of 14 non-steroidal anti-inflammatory drugs and a metamizole metabolite in swine muscle was developed using liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS). The samples were extracted with acetonitrile (ACN) in solid-liquid extraction followed by a low-temperature partitioning (LLE-LTP) process at -20 ± 2°C. After evaporation to dryness, the residue was reconstituted with hexane and a mixture of water:acetonitrile (1:1). LC separation was achieved on a reversed-phase (RP18) column with gradient elution using water (phase A) and ACN (phase B) both containing 1 mmol l(-)(1) ammonium acetate (NH4COO) with 0.025% acetic acid. Analysis was carried out on a triple-quadrupole tandem mass spectrometer (LC-MS/MS) in multiple reaction monitoring mode using an electrospray interface in negative and positive mode in a single run. Method validation was performed according to the criteria of Commission Decision No. 2002/657/EC. The matrix effect and linearity were evaluated. Decision limit (CCα), detection capability (CCβ), accuracy and repeatability of the method are also reported. The proposed method proved to be simple, easy and adequate for high-throughput analysis and was applied to routine analysis by the Brazilian Ministry of Agriculture, Livestock and Food Supply.

  1. Analysis of phenolic compounds from different morphological parts of Helichrysum devium by liquid chromatography with on-line UV and electrospray ionization mass spectrometric detection.

    PubMed

    Gouveia, Sandra C; Castilho, Paula C

    2009-12-01

    A simple and rapid method has been used for the screening and identification of the main phenolic compounds from Helichrysum devium using high-performance liquid chromatography with on-line UV and electrospray ionization mass spectrometric detection (LC-DAD/ESI-MS(n)). The total aerial parts and different morphological parts of the plant, namely leaves, flowers and stems, were analyzed separately. A total of 34 compounds present in the methanolic extract from Helichrysum devium were identified or tentatively characterized based on their UV and mass spectra and retention times. Three of these compounds were positively identified by comparison with reference standards. The phenolic compounds included derivatives of quinic acid, O-glycosylated flavonoids, a caffeic acid derivative and a protocatechuic acid derivative. The characteristic loss of 206 Da from malonylcaffeoyl quinic acid was used to confirm the malonyl linkage to the caffeoyl group. This contribution presents one of the first reports on the analysis of phenolic compounds from Helichrysum devium using LC-DAD/ESI-MS(n) and highlights the prominence of quinic acid derivatives as the main group of phenolic compounds present in these extracts. We also provide evidence that the methanolic extract from the flowers was significantly more complex when compared to that of other morphological parts. Copyright 2009 John Wiley & Sons, Ltd.

  2. P39-T Analysis of Oligosaccharides by Capillary-Scale High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection (CHPAEC-PAD) and On-Line Electrospray-Ionization Ion-Trap Mass Spectrometry (CHPAEC-ITMS)

    PubMed Central

    Bruggink, C.; Koeleman, C.; Barreto, V.; Lui, Y.; Pohl, C.; Ingendoh, A.; Wuhrer, M.; Hokke, C.; Deelder, A.

    2007-01-01

    High-pH anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) is an established technique for selective separation and analysis of underivatized carbohydrates. The miniaturization of chromatographic techniques by means of capillary columns, and on-line coupling to mass spectrometry are critical to the further development of glycan analysis methods that are compatible with the current requirements in clinical settings. A system has been developed based on the Dionex BioLC equipped with a microbore gradient pump with PEEK flow splitter, a FAMOS micro autosampler, a modified electrochemical cell for on-line capillary PAD, and a capillary column (380 μm i.d.) packed with a new type of anion-exchange resin. This system operates with sensitivity in the low femtomol range. In addition, an on-line capillary desalter has been developed to allow direct coupling to the Bruker Esquire 3000 ion-trap mass spectrometer with electrospray ionization interface (ESI-IT-MS). Both systems have been evaluated using oligosaccharide standards as well as urine samples exhibiting various lysosomal oligosaccharide storage diseases. Initial data indicate that the robust and selective anion-exchange system, in combination with ESI-IT-MS for structure confirmation and analysis, provides a powerful platform that complements existing nano/capillary LC-MS methods for analytical determination of oligosaccharides in biological matrices.

  3. Oligomers, organosulfates, and nitroxy organosulfates in rainwater identified by ultra-high resolution electrospray ionization FT-ICR mass spectrometry

    NASA Astrophysics Data System (ADS)

    Altieri, K. E.; Turpin, B. J.; Seitzinger, S. P.

    2008-09-01

    Wet deposition is an important removal mechanism for atmospheric organic matter, and a potentially important input for receiving ecosystems, yet less than 50% of rainwater organic matter is considered chemically characterized. Precipitation samples collected in New Jersey, USA, were analyzed by negative ion ultra-high resolution electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Elemental compositions of 552 unique molecular species were determined in the mass range 50 500 Da in the rainwater. Three main groups of organic compounds were identified: compounds containing carbon, hydrogen, and oxygen (CHO) only, sulfur (S) containing CHOS compounds, and S- and nitrogen containing CHONS compounds. Organic acids commonly identified in precipitation were detected, as well as linear alkylbenzene sulfonates, which are persistent pollutants commonly measured in river water, seawater, and sediments, but to our knowledge, not previously documented in atmospheric samples. Within the three main groups of compounds detected in the rainwater, oligomers, organosulfates, and nitroxy-organosulfates were identified. The majority of the compounds identified are products of atmospheric reactions and are known contributors to secondary organic aerosol (SOA) formed from gas phase, aerosol phase, and in-cloud reactions in the atmosphere. It is suggested that the large uncharacterized component of SOA is the main contributor to the large uncharacterized component of rainwater organic matter.

  4. Analysis of solvent dyes in refined petroleum products by electrospray ionization mass spectrometry

    USGS Publications Warehouse

    Rostad, C.E.

    2010-01-01

    Solvent dyes are used to color refined petroleum products to enable differentiation between gasoline, diesel, and jet fuels. Analysis for these dyes in the hydrocarbon product is difficult due to their very low concentrations in such a complex matrix. Flow injection analysis/electrospray ionization/mass spectrometry in both negative and positive mode was used to optimize ionization of ten typical solvent dyes. Samples of hydrocarbon product were analyzed under similar conditions. Positive electrospray ionization produced very complex spectra, which were not suitably specific for targeting only the dyes. Negative electrospray ionization produced simple spectra because aliphatic and aromatic moieties were not ionized. This enabled screening for a target dye in samples of hydrocarbon product from a spill.

  5. Optical tomograph optimized for tumor detection inside highly absorbent organs

    NASA Astrophysics Data System (ADS)

    Boutet, Jérôme; Koenig, Anne; Hervé, Lionel; Berger, Michel; Dinten, Jean-Marc; Josserand, Véronique; Coll, Jean-Luc

    2011-05-01

    This paper presents a tomograph for small animal fluorescence imaging. The compact and cost-effective system described in this article was designed to address the problem of tumor detection inside highly absorbent heterogeneous organs, such as lungs. To validate the tomograph's ability to detect cancerous nodules inside lungs, in vivo tumor growth was studied on seven cancerous mice bearing murine mammary tumors marked with Alexa Fluor 700. They were successively imaged 10, 12, and 14 days after the primary tumor implantation. The fluorescence maps were compared over this time period. As expected, the reconstructed fluorescence increases with the tumor growth stage.

  6. Trace level detection of analytes using artificial olfactometry

    NASA Technical Reports Server (NTRS)

    Wong, Bernard (Inventor); Lewis, Nathan S. (Inventor); Severin, Erik J. (Inventor)

    2001-01-01

    The present invention provides a device for detecting the presence of an analyte, wherein said analyte is a microorganism marker gas. The device comprises a sample chamber having a fluid inlet port for the influx of the microorganism marker gas; a fluid concentrator in flow communication with the sample chamber, wherein the fluid concentrator has an absorbent material capable of absorbing the microorganism marker gas and thereafter releasing a concentrated microorganism marker gas; and an array of sensors in fluid communication with the concentrated microorganism marker gas. The sensor array detects and identifies the marker gas upon its release from fluid concentrate.

  7. Effect of absorbing impurities on the accuracy of the optical method for the detection of the iodine-containing substances resulting from the processing of waste nuclear fuel

    NASA Astrophysics Data System (ADS)

    Kireev, S. V.; Simanovsky, I. G.; Shnyrev, S. L.

    2010-12-01

    The study is aimed at an increase in the accuracy of the optical method for the detection of the iodine-containing substances in technological liquids resulting form the processing of the waste nuclear fuel. It is demonstrated that the accuracy can be increased owing to the measurements at various combinations of wavelengths depending on the concentrations of impurities that are contained in the sample under study and absorb in the spectral range used for the detection of the iodine-containing substances.

  8. Broad-Range PCR Coupled with Electrospray Ionization Time of Flight Mass Spectrometry for Detection of Bacteremia and Fungemia in Patients with Neutropenic Fever.

    PubMed

    Desmet, S; Maertens, J; Bueselinck, K; Lagrou, K

    2016-10-01

    Infection is an important complication in patients with hematologic malignancies or solid tumors undergoing intensive cytotoxic chemotherapy. In only 20 to 30% of the febrile neutropenic episodes, an infectious agent is detected by conventional cultures. In this prospective study, the performance of broad-range PCR coupled with electrospray ionization time of flight mass spectrometry (PCR/ESI-MS) technology was compared to conventional blood cultures (BC) in a consecutive series of samples from high-risk hematology patients. In 74 patients, BC and a whole-blood sample for PCR/ESI-MS (Iridica BAC BSI; Abbott, Carlsbad, CA, USA) were collected at the start of each febrile neutropenic episode and, in case of persistent fever, also at day 5. During 100 different febrile episodes, 105 blood samples were collected and analyzed by PCR/ESI-MS. There was evidence of a bloodstream infection (BSI) in 36/105 cases (34%), based on 14 cases with both PCR/ESI-MS and BC positivity, 17 cases with BC positivity only, and 5 cases with PCR/ESI-MS positivity only. The sensitivity of PCR/ESI-MS was 45%, specificity was 93%, and the negative predictive value was 80% compared to blood culture. PCR/ESI-MS detected definite pathogens (Fusobacterium nucleatum and Streptococcus pneumoniae) missed by BC, whereas it missed both Gram-negative and Gram-positive organisms detected by BC. PCR/ESI-MS testing detected additional microorganisms but showed a low sensitivity (45%) compared to BC in neutropenic patients. Our results indicate a lower concordance between BC and PCR/ESI-MS in the neutropenic population than what has been previously reported in other patient groups with normal white blood cell distribution, and a lower sensitivity than other PCR-based methods. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  9. Finding a Single Molecule in a Haystack: Optical Detection and Spectroscopy of Single Absorbers in Solids

    DTIC Science & Technology

    1989-08-18

    CODES 18 SUBJECT TERMS (Continue on reverse if necessary and identify by block number) FIELD GROUP SUB-GROUP Single Molecule Detection Pentacene in p...and 10 additional pentacene molecules. This may be accomplished by- a combination of laser FM spectroscopy and either Stark or ultrasonic double...6099 408-927-2426 ABSTRACT: Single-absorber optical spectroscopy in solids is described for the case of finding a single pentacene molecule in a

  10. A Survey of Metal Lines at High-redshift. I. SDSS Absorption Line Studies—the Methodology and First Search Results for O VI

    NASA Astrophysics Data System (ADS)

    Frank, S.; Mathur, S.; Pieri, M.; York, D. G.

    2010-09-01

    We report the results of a systematic search for signatures of metal lines in quasar spectra of the Sloan Digital Sky Survey (SDSS) data release 3 (DR3), focusing on finding intervening absorbers via detection of their O VI doublet. Here, we present the search algorithm and criteria for distinguishing candidates from spurious Lyα forest lines. In addition, we compare our findings with simulations of the Lyα forest in order to estimate the detectability of O VI doublets over various redshift intervals. We have obtained a sample of 1756 O VI doublet candidates with rest-frame equivalent width (EW) >=0.05 Å in 855 active galactic nuclei spectra (out of 3702 objects with redshifts in the accessible range for O VI detection). This sample is further subdivided into three groups according to the likelihood of being real and the potential for follow-up observation of the candidate. The group with the cleanest and most secure candidates is comprised of 145 candidates. Sixty-nine of these reside at a velocity separation >=5000 km s-1 from the QSO and can therefore be classified tentatively as intervening absorbers. Most of these absorbers have not been picked up by earlier, automated QSO absorption line detection algorithms. This sample increases the number of known O VI absorbers at redshifts beyond z abs>= 2.7 substantially.

  11. Ultrasensitive sensing with three-dimensional terahertz metamaterial absorber

    NASA Astrophysics Data System (ADS)

    Tan, Siyu; Yan, Fengping; Wang, Wei; Zhou, Hong; Hou, Yafei

    2018-05-01

    Planar metasurfaces and metamaterial absorbers have shown great promise for label-free sensing applications at microwaves, optical and terahertz frequencies. The realization of high-quality-factor resonance in these structures is of significant interest to enhance the sensing sensitivities to detect minute frequency shifts. We propose and demonstrate in this manuscript an ultrasensitive terahertz metamaterial absorber sensor based on a three-dimensional split ring resonator absorber with a high quality factor of 60.09. The sensing performance of the proposed absorber sensor was systematically investigated through detailed numerical calculations and a maximum refractive index sensitivity of 34.40% RIU‑1 was obtained. Furthermore, the absorber sensor can maintain a high sensitivity for a wide range of incidence angles up to 60° under TM polarization incidence. These findings would improve the design flexibility of the absorber sensors and further open up new avenues to achieve ultrasensitive sensing in the terahertz regime.

  12. Process Analyzer

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The ChemScan UV-6100 is a spectrometry system originally developed by Biotronics Technologies, Inc. under a Small Business Innovation Research (SBIR) contract. It is marketed to the water and wastewater treatment industries, replacing "grab sampling" with on-line data collection. It analyzes the light absorbance characteristics of a water sample, simultaneously detects hundreds of individual wavelengths absorbed by chemical substances in a process solution, and quantifies the information. Spectral data is then processed by ChemScan analyzer and compared with calibration files in the system's memory in order to calculate concentrations of chemical substances that cause UV light absorbance in specific patterns. Monitored substances can be analyzed for quality and quantity. Applications include detection of a variety of substances, and the information provided enables an operator to control a process more efficiently.

  13. Final Report on the Detection of Green Monopropellants

    NASA Technical Reports Server (NTRS)

    Gibson, Tracy L.; DeVor, Robert W.; Bauer, Brint M.; Captain, James; Coutts, Janelle L.; Surma, Jan M.

    2015-01-01

    In 2014, National Aeronautics and Space Administration (NASA) Kennedy Space Center (KSC) funded a project titled "Familiarization and Detection of Green Monopropellants" utilizing Independent Research and Technology Development (IR&TD) and Center Innovation Fund (CIF) funding. The purpose of the project was to evaluate methods of detection for ammonium dinitramide (ADN) and hydroxylammonium nitrate (HAN). An Engineering Services Contract (ESC) task order was created with the scope of evaluation of several methods of detecting ADN- and HAN-based propellants, as well as development of methods for detection. Detection methods include developed methods such as colorimetric indicating absorbent socks, and commercial-off-the- shelf (COTS) units for ammonia detection. An additional goal of the task order was for ESC to become familiar with ADN's and HAN's material properties and material compatibility. Two approaches were initially investigated as possible methods for the detection of HAN (or AFM315E) and ADN (or LMP-103S). These approaches were colorimetric analysis and instrumentation-based COTS vapor sensors utilization. Initial testing showed that the relatively non-existent vapor pressure of the AF-M315E (of which HAN is a major component) propellant would make the use of COTS sensors difficult for real-time area monitoring of HAN; a small response was detected through the use of active COTS sensors, including the RAE Systems MultiRAE Lite and Drager X-act (registered) 5000, but the levels detected were below the threshold limit value for the toxic gas ammonia. Therefore, a detection system ased upon a colorimetric indicator impregnated into an absorbent material was developed. Preliminary analysis (ESC-245-FDG-001) identified a particularly outstanding candidate as a colorimetric indicator for the detection of the presence of AF-M315E in the form of a Methyl Red (Basic) indicator. Materials impregnated with this indicator exhibit significant color change and the materials are not susceptible to interference from exposure to water or carbon dioxide. The completed detection system for HAN/AF-M315E consists of absorbent socks packed with Fisher Universal Spill Absorbent capable of absorbing and containing any propellant spills that they come into contact with along with indicating wipes. The absorbent socks are also chemically treated with a Methyl Red (Basic) indicator solution to provide the end user with a visual indication that a leak has occurred and proper protective precautions must be undertaken. An added benefit of this detection system is that the absorbent socks should neutralize/absorb any commodity that it comes into contact with (until saturation is reached). Additional adsorbent socks can be deployed until a color change is not seen, indicating that the HAN/AF-M315E contamination has been contained. The indicating wipes provide the user the opportunity to wipe surfaces to determine if there is any HAN/AF-M315E or HAN/AFM315E residue present. The wipes should allow the detection of fuel levels that may be too small to detect with the absorbent socks. The development of a detection system for the ADN/LMP-103S focused on the use of various COTS sensors used as real-time area monitoring devices and personal dosimeters. These COTS based sensor systems were of several different types, including both actively pumped and diffusion-based passive systems, as well as a "rope"-type chemical sensing cable. The results highlighted some of the major differences between the two monopropellants undergoing evaluation. Unlike HAN, ADN (which is the major constituent of LMP-103S) exhibits a much more volatile nature in comparison to AF-M315E. In fact, testing showed that a large percentage of the fuel was lost during the sampling measurement (greater than 10 percent by mass); although this testing cannot tell if the volatile component is the ADN itself or another component of the monopropellant solution. Not surprisingly, all four of the procured vapor-based COTS sensors showed positive results when exposed to solutions of the LMP-103S (ESC-245-FDG-002). The completed detection system for ADN/LMP-103S consists of a combination of two of the tested COTS sensor systems, the RAE Systems MultiRAE Lite and the BW Technologies GasAlert Extreme. These systems are meant to be used in conjunction with one another, which allows for the end-user to have both real-time area monitoring (MultiRAE Lite) as well as a personal dosimeter device (GasAlert Extreme) which can be worn as additional personal protective equipment. An stainless steel extension wand was fabricated and included in the detection system for the MultiRAE Lite to allow for more remote sensing, and connects via the active pumping inlet of the sensor. As stated, the final results of this testing resulted in the production of two "kits" which can be used for the detection of HAN/AF-M315E and ADN/LMP-103s (ESC-245-FDG-003).

  14. The electrospray and its application to targeted drug inhalation.

    PubMed

    Gomez, Alessandro

    2002-12-01

    This review explains the fundamentals of electrostatic spray (electrospray) atomization, with emphasis on operation in the so called cone-jet mode, which produces droplets with a very narrow size distribution. Since the control of droplet size is key to maximizing distal lung deposition, the electrospray should be well-suited to targeted drug inhalation. Electrospray droplets are a few micrometers in diameter, but they originate from a much larger nozzle, which allows nebulization of suspensions without clogging. Also discussed are: the physical principles of the break-up of the liquid ligament; droplet dispersion by Coulombic forces; and the most important scaling law linking the droplet size to liquid flow rate and liquid physical properties. The effects of the most critical of those properties may result in some restrictions on drug formulation. Droplets produced by electrospray are electrically charged, so to prevent electrostatic image forces from causing upper respiratory tract deposition. The charge is neutralized by generating a corona discharge of opposite polarity. Briefly discussed are the main differences between the laboratory systems (with which the electrospray has been quantitatively characterized during research in the past 10 years) and commercial electrospray inhalers under development at BattellePharma. Some remarkable miniaturization has incorporated liquid pump, power supply, breath activation, and dose counter into a palm-size portable device. The maximum flow rates dispersed from these devices are in the range of 8-16 microL/s, which makes them suitable for practical drug inhalation therapy. Fabrication is economically competitive with inexpensive nebulizers. Dramatic improvements in respirable dose efficiency (up to 78% by comparison with commercial metered-dose inhalers and dry powder inhalers) should ensure the commercialization of this promising technology for targeted drug inhalation.

  15. Identification and quantification of five macrolide antibiotics in several tissues, eggs and milk by liquid chromatography-electrospray tandem mass spectrometry.

    PubMed

    Dubois, M; Fluchard, D; Sior, E; Delahaut, P

    2001-04-05

    We present an electrospray high-performance liquid chromatographic tandem mass spectrometric (HPLC-MS-MS) method capable of determining in several tissues (muscle, kidney, liver), eggs and milk the following five macrolides: tylosin, tilmicosin, spiramycin, josamycin, erythromycin. Roxithromycin was used as an internal standard. The method uses extraction in a Tris buffer at pH 10.5, followed by protein precipitation with sodium tungstate and clean-up on an Oasis solid-phase extraction column. The HPLC separation was performed on a Purospher C18 column (125 x 3 mm I.D.) protected by a guard column, with a gradient of aqueous 0.1 M ammonium acetate-acetonitrile as the mobile phase at a flow-rate of 0.7 ml min(-1). Protonated molecules served as precursor ions for electrospray ionisation in the positive ion mode and four product ions were chosen for each analyte for multiple reaction monitoring (MRM). A validation study was conducted to confirm the five macrolides by MRM HPLC-MS-MS analysis of a negative control and fortified samples. All of the samples analysed were confirmed with four ions. The ion ratio reproducibility limit ranged from 2.4 to 15%. All compounds could be detected and quantified at half-maximum residue limits (MRLs). The method is specific, quantitative and reproducible enough to conform to European Union recommendations within the concentration range 0.5 MRL-2 MRL (accuracy: 80 to 110%, relative standard deviation: 2 to 13%). This whole method allows extraction and analysis of up to 50 samples per day.

  16. Electrospray Ionization Efficiency Is Dependent on Different Molecular Descriptors with Respect to Solvent pH and Instrumental Configuration

    PubMed Central

    Kiontke, Andreas; Oliveira-Birkmeier, Ariana; Opitz, Andreas

    2016-01-01

    Over the past decades, electrospray ionization for mass spectrometry (ESI-MS) has become one of the most commonly employed techniques in analytical chemistry, mainly due to its broad applicability to polar and semipolar compounds and the superior selectivity which is achieved in combination with high resolution separation techniques. However, responsiveness of an analytical method also determines its suitability for the quantitation of chemical compounds; and in electrospray ionization for mass spectrometry, it can vary significantly among different analytes with identical solution concentrations. Therefore, we investigated the ESI-response behavior of 56 nitrogen-containing compounds including aromatic amines and pyridines, two compound classes of high importance to both, synthetic organic chemistry as well as to pharmaceutical sciences. These compounds are increasingly analyzed employing ESI mass spectrometry detection due to their polar, basic character. Signal intensities of the peaks from the protonated molecular ion (MH+) were acquired under different conditions and related to compound properties such as basicity, polarity, volatility and molecular size exploring their quantitative impact on ionization efficiency. As a result, we found that though solution basicity of a compound is the main factor initially determining the ESI response of the protonated molecular ion, other factors such as polarity and vaporability become more important under acidic solvent conditions and may nearly outweigh the importance of basicity under these conditions. Moreover, we show that different molecular descriptors may become important when using different types of instruments for such investigations, a fact not detailed so far in the available literature. PMID:27907110

  17. Mapping Lipid Alterations in Traumatically Injured Rat Spinal Cord by Desorption Electrospray Ionization Imaging Mass Spectrometry

    PubMed Central

    Girod, Marion; Shi, Yunzhou; Cheng, Ji-Xin; Cooks, R. Graham

    2010-01-01

    Desorption electrospray ionization (DESI) mass spectrometry is used in an imaging mode to interrogate the lipid profiles of 15 µm thin tissues cross sections of injured rat spinal cord and normal healthy tissue. Increased relative intensities of fatty acids, diacylglycerols and lysolipids (between +120% and +240%) as well as a small decrease in intensities of lipids (−30%) were visualized in the lesion epi-center and adjacent areas after spinal cord injury. This indicates the hydrolysis of lipids during the demyelination process due to activation of phospholipase A2 enzyme. In addition, signals corresponding to oxidative degradation products, such as prostaglandin and hydroxyeicosatetraenoic acid, exhibited increased signal intensity by a factor of two in the negative ion mode in lesions relative to the normal healthy tissue. Analysis of malondialdehyde, a product of lipid peroxidation and marker of oxidative stress, was accomplished in the ambient environment using reactive DESI mass spectrometry imaging. This was achieved by electrospraying reagent solution containing dinitrophenylhydrazine as high velocity charged droplets onto the tissue section. The hydrazine reacts selectively and rapidly with the carbonyl groups of malondialdehyde and signal intensity of twice the intensity was detected in the lesions compared to healthy spinal cord. With a small amount of tissue sample, DESI-MS imaging provides information on the composition and distribution of specific compounds (limited by the occurrence of isomeric lipids with very similar fragmentation patterns) in lesions after spinal cord injury in comparison with normal healthy tissue allowing identification of the extent of the lesion and its repair. PMID:21142140

  18. Staying Alive: Measuring Intact Viable Microbes with Electrospray Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Forsberg, Erica; Fang, Mingliang; Siuzdak, Gary

    2017-01-01

    Mass spectrometry has traditionally been the technology of choice for small molecule analysis, making significant inroads into metabolism, clinical diagnostics, and pharmacodynamics since the 1960s. In the mid-1980s, with the discovery of electrospray ionization (ESI) for biomolecule analysis, a new door opened for applications beyond small molecules. Initially, proteins were widely examined, followed by oligonucleotides and other nonvolatile molecules. Then in 1991, three intriguing studies reported using mass spectrometry to examine noncovalent protein complexes, results that have been expanded on for the last 25 years. Those experiments also raised the questions: How soft is ESI, and can it be used to examine even more complex interactions? Our lab addressed these questions with the analyses of viruses, which were initially tested for viability following electrospray ionization and their passage through a quadrupole mass analyzer by placing them on an active medium that would allow them to propagate. This observation has been replicated on multiple different systems, including experiments on an even bigger microbe, a spore. The question of analysis was also addressed in the early 2000s with charge detection mass spectrometry. This unique technology could simultaneously measure mass-to-charge and charge, allowing for the direct determination of the mass of a virus. More recent experiments on spores and enveloped viruses have given us insight into the range of mass spectrometry's capabilities (reaching 100 trillion Da), beginning to answer fundamental questions regarding the complexity of these organisms beyond proteins and genes, and how small molecules are integral to these supramolecular living structures.

  19. Preparation and optimization of submicron chitosan capsules by water-based electrospraying for food and bioactive packaging applications.

    PubMed

    Sreekumar, Sruthi; Lemke, Philipp; Moerschbacher, Bruno M; Torres-Giner, Sergio; Lagaron, Jose M

    2017-10-01

    In the present study, a well-defined set of chitosans, with different degrees of acetylation (DA) and degrees of polymerization (DP), were processed by solution electrospraying from a water-based solvent. The solution properties, in terms of surface tension, conductivity, viscosity, and pH, were characterized and related to the physico-chemical properties of the chitosans. It was observed that both DA and DP values of a given chitosan, in combination with biopolymer concentration, mainly determined solution viscosity. This was, in turn, the major driving factor that defined the electrosprayability of chitosan. In addition, the physico-chemical properties of chitosans highly influenced solution conductivity and results indicated that the chitosan solutions with low or low-to-medium values of conductivity were the most optimal for electrospraying. The results obtained here also demonstrate that a good process control can be achieved by adjusting the working conditions, i.e. applied voltage, flow-rate, and tip-to-collector distance. Finally, it was also shown that electrosprayability of chitosan with inadequate physico-chemical properties can be improved by solution mixing of very different kinds of this polysaccharide. The resultant electrosprayed submicron chitosan capsules can be applied for encapsulation of food additives and to develop bioactive coatings of interest in food packaging, where these particles alone or containing functional ingredients can be released from the package into the food to promote a health benefit.

  20. ESR spectroscopy for detecting gamma-irradiated dried vegetables and estimating absorbed doses

    NASA Astrophysics Data System (ADS)

    Kwon, Joong-Ho; Chung, Hyung-Wook; Byun, Myung-Woo

    2000-03-01

    In view of an increasing demand for food irradiation technology, the development of a reliable means of detection for the control of irradiated foods has become necessary. Various vegetable food materials (dried cabbage, carrot, chunggyungchae, garlic, onion, and green onion), which can be legally irradiated in Korea, were subjected to a detection study using ESR spectroscopy. Correlation coefficients ( R2) between absorbed doses (2.5-15 kGy) and their corresponding ESR signals were identified from ESR signals. Pre-established threshold values were successfully applied to the detection of 54 coded unknown samples of dried clean vegetables ( chunggyungchae, Brassica camestris var. chinensis), both non-irradiated and irradiated. The ESR signals of irradiated chunggyungchae decreased over a longer storage time, however, even after 6 months of ambient storage, these signals were still distinguishable from those of non-irradiated samples. The most successful estimates of absorbed dose (5 and 8 kGy) were obtained immediately after irradiation using a quadratic fit with average values of 4.85 and 8.65 kGy being calculated.

  1. Microchip electrospray: improvements in spray and signal stability during gradient elution by an inverted postcolumn makeup flow.

    PubMed

    Jung, Stephanie; Effelsberg, Uwe; Tallarek, Ulrich

    2011-12-01

    Dynamic changes in mobile phase composition during high-performance liquid chromatography (HPLC) gradient elution coupled to mass spectrometry (MS) sensitively affect electrospray modes. We investigate the impact of the eluent composition on spray stability and MS response by infusion and injection experiments with a small tetrapeptide in water-acetonitrile mixtures. The employed HPLC/electrospray (ESI)-MS configuration uses a microchip equipped with an enrichment column, a separation column, and a makeup flow (MUF) channel. One nano pump is connected to the separation column, while a second one delivers solvent of exactly inverted composition to the MUF channel. Both solvent streams are united behind the separation column, before the ESI tip, such that the resulting electrosprayed solution always has identical composition during a gradient elution. Analyte peak parameters without and with MUF compensation are determined and discussed with respect to the electrospray mode and eluent composition. The postcolumn MUF significantly improves spray and signal stability over the entire solvent gradient, without compromising the performance of the HPLC separation column. It can also be conveniently implemented on microchip platforms.

  2. The exploration of endocytic mechanisms of PLA-PEG nanoparticles prepared by coaxialtri-capillary electrospray-template removal method.

    PubMed

    Chen, Jiaming; Cao, Lihua; Cui, Yuecheng; Tu, Kehua; Wang, Hongjun; Wang, Li-Qun

    2018-01-01

    The nano-sized poly(lactic acid)-poly(ethylene glycol) (PLA-PEG) particles with core-shell structure were efficiently prepared by using coaxial tri-capillary electrospray-template removal method. The cellular uptake mechanism, intracellular distribution and exocytosis in A549 cell model of electrosprayed PLA-PEG nanoparticles were systemically studied. The drug release behavior of electrosprayed PLA-PEG nanoparticles were also investigated. Our results showed that PLA-PEG nanoparticles can be endocytosed quickly by A549 cells. The cellular uptake of PLA-PEG nanoparticles was an energy dependent endocytosis process. Caveolae-mediated endocytosis was only one of endocytosis pathways in A549 cells for PLA-PEG nanoparticles, while clathrin mediated endocytosis was not involved in the endocytosis process. The endocytosed PLA-PEG nanoparticles enriched in the head of A549 cells and only a small amount of them was transported into lysosome after 24h incubation. These findings provided insights into the application of electrosprayed PLA-PEG nanoparticles in nano drug delivery field. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Impact of molecular weight on the formation of electrosprayed chitosan microcapsules as delivery vehicles for bioactive compounds.

    PubMed

    Gómez-Mascaraque, Laura G; Sanchez, Gloria; López-Rubio, Amparo

    2016-10-05

    The molecular weight of chitosan is one of its most determinant characteristics, which affects its processability and its performance as a biomaterial. However, information about the effect of this parameter on the formation of electrosprayed chitosan microcapsules is scarce. In this work, the impact of chitosan molecular weight on its electrosprayability was studied and correlated with its effect on the viscosity, surface tension and electrical conductivity of solutions. A Discriminant Function Analysis revealed that the morphology of the electrosprayed chitosan materials could be correctly predicted using these three parameters for almost 85% of the samples. The suitability of using electrosprayed chitosan capsules as carriers for bioactive agents was also assessed by loading them with a model active compound, (-)-epigallocatechin gallate (EGCG). This encapsulation, with an estimated efficiency of around 80% in terms of preserved antioxidant activity, showed the potential to prolong the antiviral activity of EGCG against murine norovirus via gradual bioactive release combined with its protection against degradation in simulated physiological conditions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Probing the Metal Enrichment of the Intergalactic Medium at z = 5-6 Using the Hubble Space Telescope

    NASA Astrophysics Data System (ADS)

    Cai, Zheng; Fan, Xiaohui; Dave, Romeel; Finlator, Kristian; Oppenheimer, Ben

    2017-11-01

    We test the galactic outflow model by probing associated galaxies of four strong intergalactic C IV absorbers at z = 5-6 using the Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS) ramp narrowband filters. The four strong C IV absorbers reside at z = 5.74, 5.52, 4.95, and 4.87, with column densities ranging from N C IV = 1013.8 to 1014.8 cm-2. At z = 5.74, we detect an I-dropout Lyα emitter (LAE) candidate with a projected impact parameter of 42 physical kpc from the C IV absorber. This LAE candidate has a Lyα-based star formation rate (SFRLyα ) of 2 M ⊙ yr-1 and a UV-based SFR of 4 M ⊙ yr-1. Although we cannot completely rule out that this I-dropout emitter may be an [O II] interloper, its measured properties are consistent with the C IV powered galaxy at z = 5.74. For C IV absorbers at z = 4.95 and z = 4.87, although we detect two LAE candidates with impact parameters of 160 and 200 kpc, such distances are larger than that predicted from the simulations. Therefore, we treat them as nondetections. For the system at z = 5.52, we do not detect LAE candidates, placing a 3σ upper limit of SFRLyα ≈ 1.5 M ⊙ yr-1. In summary, in these four cases, we only detect one plausible C IV source at z = 5.74. Combining the modest SFR of the one detection and the three nondetections, our HST observations strongly support that smaller galaxies (SFRLyα ≲ 2 M ⊙ yr-1) are main sources of intergalactic C IV absorbers, and such small galaxies play a major role in the metal enrichment of the intergalactic medium at z ≳ 5.

  5. Quality evaluation of Desmodium styracifolium using high-performance liquid chromatography with photodiode array detection and electrospray ionisation tandem mass spectrometry.

    PubMed

    Zhou, Chan; Luo, Jian-Guang; Kong, Ling-Yi

    2012-01-01

    Desmodium styracifolium, with C-flavone glycosides as main pharmacological effective compounds, is a popular Chinese medicinal herb and has been used to treat urination disturbance, urolithiasis, edema and jaundice. However, few systematic methods have been reported on the quality control of this natural herb. To develop a method for control the quality of D. styracifolium by combining chromatographic fingerprints and major constituent quantification. Separations were performed on an Ultimate XB-C-18 column by gradient elution using acetonitrile and 0.1% aqueous formic acid. Analytes were identified by HPLC coupled with electrospray ionisation mass spectrometry experiments. Twenty common peaks in chromatographic fingerprints were first identified among 15 batches of D. styracifolium from various regions. On basis of this, a HPLC-PAD method was established to simultaneously quantify five major constituents, which was validated for limit of qualification, linearity and interday variation of precision and accuracy. The assay developed could be considered as a suitable quality control method of D. styracifolium. Copyright © 2011 John Wiley & Sons, Ltd.

  6. Neutral desorption extractive electrospray ionization mass spectrometry for fast screening sunscreen agents in cream cosmetic products.

    PubMed

    Zhang, Xinglei; Liu, Yan; Zhang, Jinghua; Hu, Zhong; Hu, Bin; Ding, Liying; Jia, Li; Chen, Huanwen

    2011-09-15

    High throughput analysis of sunscreen agents present in cream cosmetic has been demonstrated, typically 2 samples per minute, using neutral desorption extractive electrospray ionization mass spectrometry (ND-EESI-MS) without sample pretreatment. For the targeted compounds such as 4-Aminobenzoic acid and oxybenzone, ND-EESI-MS method provided linear signal responses in the range of 1-100 ppb. Limits of detection (LOD) of the method were estimated at sub-ppb levels for the analytes tested. Reasonable relative standard deviation (RSD=8.4-16.0%) was obtained as a result of 10 independent measurements for commercial cosmetics samples spiked with each individual sunscreen agents at 1-10 ppb. Acceptable recoveries were achieved in the range of 87-116% for direct analysis of commercial cream cosmetic samples. The experimental data demonstrate that ND-EESI-MS is a useful tool for high throughput screening of sunscreen agents in highly viscous cream cosmetic products, with the capability to obtain quantitative information of the analytes. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Differentiation of oral bacteria in in vitro cultures and human saliva by secondary electrospray ionization - mass spectrometry

    NASA Astrophysics Data System (ADS)

    Bregy, Lukas; Müggler, Annick R.; Martinez-Lozano Sinues, Pablo; García-Gómez, Diego; Suter, Yannick; Belibasakis, Georgios N.; Kohler, Malcolm; Schmidlin, Patrick R.; Zenobi, Renato

    2015-10-01

    The detection of bacterial-specific volatile metabolites may be a valuable tool to predict infection. Here we applied a real-time mass spectrometric technique to investigate differences in volatile metabolic profiles of oral bacteria that cause periodontitis. We coupled a secondary electrospray ionization (SESI) source to a commercial high-resolution mass spectrometer to interrogate the headspace from bacterial cultures and human saliva. We identified 120 potential markers characteristic for periodontal pathogens Aggregatibacter actinomycetemcomitans (n = 13), Porphyromonas gingivalis (n = 70), Tanerella forsythia (n = 30) and Treponema denticola (n = 7) in in vitro cultures. In a second proof-of-principle phase, we found 18 (P. gingivalis, T. forsythia and T. denticola) of the 120 in vitro compounds in the saliva from a periodontitis patient with confirmed infection with P. gingivalis, T. forsythia and T. denticola with enhanced ion intensity compared to two healthy controls. In conclusion, this method has the ability to identify individual metabolites of microbial pathogens in a complex medium such as saliva.

  8. Profiling of acarviostatin family secondary metabolites secreted by Streptomyces coelicoflavus ZG0656 using ultraperformance liquid chromatography coupled with electrospray ionization mass spectrometry.

    PubMed

    Geng, Peng; Meng, Xiansheng; Bai, Gang; Luo, Guoan

    2008-10-01

    Profiling of acarviostatin family secondary metabolites secreted by Streptomyces coelicoflavus ZG0656 was performed by means of a rapid and facile procedure using ultraperformance liquid chromatography coupled with electrospray ionization mass spectrometry (UPLC/ESI-MS). The acarviostatins were separated on a C18 UPLC column with a series of acetonitrile-aqueous ammonia gradients. The target homologues were detected using the multiple reaction monitoring mode, and the chemical structures were confirmed by analyzing the diagnostic fragment ions in their MS/MS spectra. All six known reference acarviostatins (I03, II03, II13, II23, III03, IV03) were thus identified. In addition, at least 74 acarviostatin homologues, including 65 novel compounds, were characterized. Some of the features of the novel structures included having up to five acarviosine moieties, an acarviosine moiety at the reducing terminus, or an incomplete acarviosine moiety at the nonreducing terminus. This type of investigation may be useful for researchers who study secondary metabolomics in microorganisms and plants, especially those who perform metabolic profiling of aminooligosaccharides and other natural products with similar structures.

  9. Electrospray Post-Ionization Mass Spectrometry of Electrosurgical Aerosols

    NASA Astrophysics Data System (ADS)

    Guenther, Sabine; Schäfer, Karl-Christian; Balog, Júlia; Dénes, Júlia; Majoros, Tamás; Albrecht, Katalin; Tóth, Miklós; Spengler, Bernhard; Takáts, Zoltán

    2011-11-01

    The feasibility of electrospray (ES) ionization of aerosols generated by electrosurgical disintegration methods was investigated. Although electrosurgery itself was demonstrated to produce gaseous ions, post-ionization methods were implemented to enhance the ion yield, especially in those cases when the ion current produced by the applied electrosurgical method is not sufficient for MS analysis. Post-ionization was implemented by mounting an ES emitter onto a Venturi pump, which is used for ion transfer. The effect of various parameters including geometry, high voltage setting, flow parameters, and solvent composition was investigated in detail. Experimental setups were optimized accordingly. ES post-ionization was found to yield spectra similar to those obtained by the REIMS technique, featuring predominantly lipid-type species. Signal enhancement was 20- to 50-fold compared with electrosurgical disintegration in positive mode, while no improvement was observed in negative mode. ES post-ionization was also demonstrated to allow the detection of non-lipid type species in the electrosurgical aerosol, including drug molecules. Since the tissue specificity of the MS data was preserved in the ES post-ionization setup, feasibility of tissue identification was demonstrated using different electrosurgical methods.

  10. Direct analysis of herbal powders by pipette-tip electrospray ionization mass spectrometry.

    PubMed

    Wang, Haixing; So, Pui-Kin; Yao, Zhong-Ping

    2014-01-27

    Conventional electrospray ionization mass spectrometry (ESI-MS) is widely used for analysis of solution samples. The development of solid-substrate ESI-MS allows direct ionization analysis of bulky solid samples. In this study, we developed pipette-tip ESI-MS, a technique that combines pipette tips with syringe and syringe pump, for direct analysis of herbal powders, another common form of samples. We demonstrated that various herbal powder samples, including herbal medicines and food samples, could be readily online extracted and analyzed using this technique. Various powder samples, such as Rhizoma coptidis, lotus plumule, great burdock achene, black pepper, Panax ginseng, roasted coffee beans, Fructus Schisandrae Chinensis and Fructus Schisandrae Sphenantherae, were analyzed using pipette-tip ESI-MS and quality mass spectra with stable and durable signals could be obtained. Both positive and negative ion modes were attempted and various compounds including amino acids, oligosaccharides, glycosides, alkaloids, organic acids, ginosensides, flavonoids and lignans could be detected. Principal component analysis (PCA) based on the acquired mass spectra allowed rapid differentiation of closely related herbal species. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Simultaneous quantification of eight bioactive components of Houttuynia cordata and related Saururaceae medicinal plants by on-line high performance liquid chromatography-diode array detector-electrospray mass spectrometry.

    PubMed

    Meng, Jiang; Leung, Kelvin Sze-Yin; Dong, Xiao-Ping; Zhou, Yi-Sheng; Jiang, Zhi-Hong; Zhao, Zhong-Zhen

    2009-12-01

    An on-line high performance liquid chromatography (HPLC)-diode array detector (DAD)-electrospray ionization mass spectrometry (ESI-MS) method has been developed to quantify simultaneously eight bioactive chemical components in Houttuynia cordata Thunb and related Saururaceae medicinal plants. Simultaneous separation of these eight compounds was achieved on a C(18) analytical column with gradient elution of acetonitrile and 0.2% acetic acid (v/v) at a flow rate of 0.6 mL/min and being detected at 280 nm. These eight compounds were completely separated within 90 min. Good linear regression relationship (r(2)>0.9978) within test ranges was shown in all calibration curves. Good repeatabilty for the quantification of these eight compounds in H.cordata was also demonstrated in this method, with intra- and inter-day variations less than 3.0%. The method established was successfully applied to quantify eight bioactive compounds in closely related species of H.cordata, which provides a new basis for quality assessment of H.cordata.

  12. Microfluidic chip for peptide analysis with an integrated HPLC column, sample enrichment column, and nanoelectrospray tip.

    PubMed

    Yin, Hongfeng; Killeen, Kevin; Brennen, Reid; Sobek, Dan; Werlich, Mark; van de Goor, Tom

    2005-01-15

    Current nano-LC/MS systems require the use of an enrichment column, a separation column, a nanospray tip, and the fittings needed to connect these parts together. In this paper, we present a microfabricated approach to nano-LC, which integrates these components on a single LC chip, eliminating the need for conventional LC connections. The chip was fabricated by laminating polyimide films with laser-ablated channels, ports, and frit structures. The enrichment and separation columns were packed using conventional reversed-phase chromatography particles. A face-seal rotary valve provided a means for switching between sample loading and separation configurations with minimum dead and delay volumes while allowing high-pressure operation. The LC chip and valve assembly were mounted within a custom electrospray source on an ion-trap mass spectrometer. The overall system performance was demonstrated through reversed-phase gradient separations of tryptic protein digests at flow rates between 100 and 400 nL/min. Microfluidic integration of the nano-LC components enabled separations with subfemtomole detection sensitivity, minimal carryover, and robust and stable electrospray throughout the LC solvent gradient.

  13. Is electrospray emission really due to columbic forces?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aliotta, Francesco, E-mail: aliotta@ipcf.cnr.it; Ponterio, Rosina C.; Salvato, Gabriele

    2014-09-15

    Electrospray ionization (ESI) is a widely adopted soft ionization method for mass spectroscopy (MS). In spite of the undeniable success of the technique, its mechanisms are difficult to be analytically modelled because the process is characterized by non-equilibrium conditions. The common belief is that the formation of gas-phase ions takes place at the apex of the Taylor cone via electrophoretic charging. The charge balance implies that a conversion of electrons to ions should occur at the metal-liquid interface of the injector needle. We have detected that the above description is based on unproved assumptions which are not consistent with themore » correct evaluation of the problem. The comparison between experiments performed under the usual geometry and observations obtained under symmetric field configurations suggests that the emitted droplets cannot be significantly charged or, at least, that any possible ionization mechanism is so poorly efficient to ensure that columbic forces cannot play a major role in jet formation, even in cases where the liquid consists of a solution of ionic species. Further work is required to clearly understand how ionization occurs in ESI-MS.« less

  14. Application of ESI-HRMS for molybdenum speciation in natural waters: An investigation of molybdate-halide reactions.

    PubMed

    Dang, Duc Huy; Evans, R Douglas

    2018-03-01

    High resolution electrospray ionization mass spectrometry (ESI-HRMS) was used to study the speciation of molybdate in interaction with halides (Cl, F, Br). Desolvation during electrospray ionization induced alteration of aqueous species but method optimization successfully suppressed artefact compounds. At low Mo concentrations, chloro(oxo)molybdate and fluoro(oxo)molybdate species were found and in natural samples, MoO 3 Cl was detected for the first time, to the best of our knowledge. Apparent equilibrium constants for Cl substitution on molybdate were calculated for a range of pH values from 4.5 to 8.5. A minor alteration in speciation during the gas phase (conversion of doubly charged MoO 4 2- to HMoO 4 - ) did not allow investigation of the molybdate acid-base properties; however this could be determined by speciation modeling. This study provides further evidence that ESI-HRMS is a fast and suitable tool to Deceasedassess the speciation of inorganic compounds such as Mo. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Electrospray-printed nanostructured graphene oxide gas sensors

    NASA Astrophysics Data System (ADS)

    Taylor, Anthony P.; Velásquez-García, Luis F.

    2015-12-01

    We report low-cost conductometric gas sensors that use an ultrathin film made of graphene oxide (GO) nanoflakes as transducing element. The devices were fabricated by lift-off metallization and near-room temperature, atmospheric pressure electrospray printing using a shadow mask. The sensors are sensitive to reactive gases at room temperature without requiring any post heat treatment, harsh chemical reduction, or doping with metal nanoparticles. The sensors’ response to humidity at atmospheric pressure tracks that of a commercial sensor, and is linear with changes in humidity in the 10%-60% relative humidity range while consuming <6 μW. Devices with GO layers printed by different deposition recipes yielded nearly identical response characteristics, suggesting that intrinsic properties of the film control the sensing mechanism. The gas sensors successfully detected ammonia at concentrations down to 500 ppm (absolute partial pressure of ˜5 × 10-4 T) at ˜1 T pressure, room temperature conditions. The sensor technology can be used in a great variety of applications including air conditioning and sensing of reactive gas species in vacuum lines and abatement systems.

  16. Electrospray-printed nanostructured graphene oxide gas sensors.

    PubMed

    Taylor, Anthony P; Velásquez-García, Luis F

    2015-12-18

    We report low-cost conductometric gas sensors that use an ultrathin film made of graphene oxide (GO) nanoflakes as transducing element. The devices were fabricated by lift-off metallization and near-room temperature, atmospheric pressure electrospray printing using a shadow mask. The sensors are sensitive to reactive gases at room temperature without requiring any post heat treatment, harsh chemical reduction, or doping with metal nanoparticles. The sensors' response to humidity at atmospheric pressure tracks that of a commercial sensor, and is linear with changes in humidity in the 10%-60% relative humidity range while consuming <6 μW. Devices with GO layers printed by different deposition recipes yielded nearly identical response characteristics, suggesting that intrinsic properties of the film control the sensing mechanism. The gas sensors successfully detected ammonia at concentrations down to 500 ppm (absolute partial pressure of ∼5 × 10(-4) T) at ∼1 T pressure, room temperature conditions. The sensor technology can be used in a great variety of applications including air conditioning and sensing of reactive gas species in vacuum lines and abatement systems.

  17. Sensitive electrospray mass spectrometry analysis of one-bead-one-compound peptide libraries labeled by quaternary ammonium salts.

    PubMed

    Bąchor, Remigiusz; Cydzik, Marzena; Rudowska, Magdalena; Kluczyk, Alicja; Stefanowicz, Piotr; Szewczuk, Zbigniew

    2012-08-01

    A rapid and straightforward method for high-throughput analysis of single resin beads from one-bead-one-compound combinatorial libraries with high resolution electrospray ionization tandem mass spectrometry (HR ESI-MS/MS) is presented. The application of an efficient method of peptide derivatization by quaternary ammonium salts (QAS) formation increases ionization efficiency and reduces the detection limit, allowing analysis of trace amounts of compounds by ESI-MS. Peptides, synthesized on solid support, contain a new cleavable linker composed of a Peg spacer (9-aza-3,6,12,15-tetraoxa-10-on-heptadecanoic acid), lysine with ɛ-amino group marked by the N,N,N-triethylglycine salt, and methionine, which makes possible the selective cleavage by cyanogen bromide. Even a small portion of peptides derivatized by QAS cleaved from a single resin bead is sufficient for sequencing by HR ESI-MS/MS experiments. The developed strategy was applied to a small training library of α chymotrypsin substrates. The obtained results confirm the applicability of the proposed method in combinatorial chemistry.

  18. A simple and selective method for determination of phthalate biomarkers in vegetable samples by high pressure liquid chromatography-electrospray ionization-tandem mass spectrometry.

    PubMed

    Zhou, Xi; Cui, Kunyan; Zeng, Feng; Li, Shoucong; Zeng, Zunxiang

    2016-06-01

    In the present study, solid-phase extraction cartridges including silica reversed-phase Isolute C18, polymeric reversed-phase Oasis HLB and mixed-mode anion-exchange Oasis MAX, and liquid-liquid extractions with ethyl acetate, n-hexane, dichloromethane and its mixtures were compared for clean-up of phthalate monoesters from vegetable samples. Best recoveries and minimised matrix effects were achieved using ethyl acetate/n-hexane liquid-liquid extraction for these target compounds. A simple and selective method, based on sample preparation by ultrasonic extraction and liquid-liquid extraction clean-up, for the determination of phthalate monoesters in vegetable samples by liquid chromatography/electrospray ionisation-tandem mass spectrometry was developed. The method detection limits for phthalate monoesters ranged from 0.013 to 0.120 ng g(-1). Good linearity (r(2)>0.991) between MQLs and 1000× MQLs was achieved. The intra- and inter-day relative standard deviation values were less than 11.8%. The method was successfully used to determine phthalate monoester metabolites in the vegetable samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Mass Spectrometric Imaging Using Laser Ablation and Solvent Capture by Aspiration (LASCA)

    NASA Astrophysics Data System (ADS)

    Brauer, Jonathan I.; Beech, Iwona B.; Sunner, Jan

    2015-09-01

    A novel interface for ambient, laser ablation-based mass spectrometric imaging (MSI) referred to as laser ablation and solvent capture by aspiration (LASCA) is presented and its performance demonstrated using selected, unaltered biological materials. LASCA employs a pulsed 2.94 μm laser beam for specimen ablation. Ablated materials in the laser plumes are collected on a hanging solvent droplet with electric field-enhanced trapping, followed by aspiration of droplets and remaining plume material in the form of a coarse aerosol into a collection capillary. The gas and liquid phases are subsequently separated in a 10 μL-volume separatory funnel, and the solution is analyzed with electrospray ionization in a high mass resolution Q-ToF mass spectrometer. The LASCA system separates the sampling and ionization steps in MSI and combines high efficiencies of laser plume sampling and of electrospray ionization (ESI) with high mass resolution MS. Up to 2000 different compounds are detected from a single ablation spot (pixel). Using the LASCA platform, rapid (6 s per pixel), high sensitivity, high mass-resolution ambient imaging of "as-received" biological material is achieved routinely and reproducibly.

  20. Electrospray ionization mass analysis of normal and genetic variants of human serum albumin.

    PubMed

    Brennan, S O

    1998-11-01

    Both normal albumin (Al A) and genetically modified forms were isolated from six heterozygous subjects. Albumins from each individual were analyzed by electrospray ionization mass spectrometry (ESI MS), and the mass was compared with that predicted from the protein sequence. In all cases, the Al A was heterogeneous, with components of mass (+/- SE) 66463+/-4, 66586+/-3, and 66718+/-5 Da. Each genetic variant showed similar heterogeneity. The mass increase in Al Casebrook (2214 Da) was very close to that predicted (2205 Da) from protein and carbohydrate sequence analysis, whereas the increase in Al Redhill (2378 Da) was close to that expected (2392 Da) for an Arg-albumin with a disialylated N-linked biantennary oligosaccharide and an Ala-->Thr mutation. The circulating proalbumins, Christchurch and Blenheim, had mass increases of 748 and 756 Da, respectively, over Al A; in excellent agreement with theoretical values of 744 and 756. Clear shifts in mass were also detected for the point substitutions 177Cys-->Phe (44 Da), 1Asp-->Val (20 Da), and Arg-albumin (160 Da).

  1. Comprehensive Characterization of Extractable and Nonextractable Phenolic Compounds by High-Performance Liquid Chromatography-Electrospray Ionization-Quadrupole Time-of-Flight of a Grape/Pomegranate Pomace Dietary Supplement.

    PubMed

    Pérez-Ramírez, Iza F; Reynoso-Camacho, Rosalía; Saura-Calixto, Fulgencio; Pérez-Jiménez, Jara

    2018-01-24

    Grape and pomegranate are rich sources of phenolic compounds, and their derived products could be used as ingredients for the development of functional foods and dietary supplements. However, the profile of nonextractable or macromolecular phenolic compounds in these samples has not been evaluated. Here, we show a comprehensive characterization of extractable and nonextractable phenolic compounds of a grape/pomegranate pomace dietary supplement using high-performance liquid chromatography-electrospray ionization-quadrupole time-of-flight (HPLC-ESI-QTOF) and matrix-assisted laser desorption/ionization (MALDI)-TOF techniques. The main extractable phenolic compounds were several anthocyanins (principally malvidin 3-O-glucoside) as well as gallotannins and gallagyl derivatives; some phenolic compounds were reported in grape or pomegranate for the first time. Additionally, there was a high proportion of nonextractable phenolic compounds, including vanillic acid, and dihydroxybenzoic acid. Unidentified polymeric structures were detected by MALDI-TOF MS analysis. This study shows that mixed grape and pomegranate pomaces are a source of different classes of phenolic compounds including a high proportion of nonextractable phenolic compounds.

  2. Capillary electrophoresis electrospray ionization mass spectrometry interface

    DOEpatents

    Smith, Richard D.; Severs, Joanne C.

    1999-01-01

    The present invention is an interface between a capillary electrophoresis separation capillary end and an electrospray ionization mass spectrometry emitter capillary end, for transporting an anolyte sample from a capillary electrophoresis separation capillary to a electrospray ionization mass spectrometry emitter capillary. The interface of the present invention has: (a) a charge transfer fitting enclosing both of the capillary electrophoresis capillary end and the electrospray ionization mass spectrometry emitter capillary end; (b) a reservoir containing an electrolyte surrounding the charge transfer fitting; and (c) an electrode immersed into the electrolyte, the electrode closing a capillary electrophoresis circuit and providing charge transfer across the charge transfer fitting while avoiding substantial bulk fluid transfer across the charge transfer fitting. Advantages of the present invention have been demonstrated as effective in providing high sensitivity and efficient analyses.

  3. Narrowband light detection via internal quantum efficiency manipulation of organic photodiodes

    NASA Astrophysics Data System (ADS)

    Armin, Ardalan; Jansen-van Vuuren, Ross D.; Kopidakis, Nikos; Burn, Paul L.; Meredith, Paul

    2015-02-01

    Spectrally selective light detection is vital for full-colour and near-infrared (NIR) imaging and machine vision. This is not possible with traditional broadband-absorbing inorganic semiconductors without input filtering, and is yet to be achieved for narrowband absorbing organic semiconductors. We demonstrate the first sub-100 nm full-width-at-half-maximum visible-blind red and NIR photodetectors with state-of-the-art performance across critical response metrics. These devices are based on organic photodiodes with optically thick junctions. Paradoxically, we use broadband-absorbing organic semiconductors and utilize the electro-optical properties of the junction to create the narrowest NIR-band photoresponses yet demonstrated. In this context, these photodiodes outperform the encumbent technology (input filtered inorganic semiconductor diodes) and emerging technologies such as narrow absorber organic semiconductors or quantum nanocrystals. The design concept allows for response tuning and is generic for other spectral windows. Furthermore, it is material-agnostic and applicable to other disordered and polycrystalline semiconductors.

  4. Improvements in brain activation detection using time-resolved diffuse optical means

    NASA Astrophysics Data System (ADS)

    Montcel, Bruno; Chabrier, Renee; Poulet, Patrick

    2005-08-01

    An experimental method based on time-resolved absorbance difference is described. The absorbance difference is calculated over each temporal step of the optical signal with the time-resolved Beer-Lambert law. Finite element simulations show that each step corresponds to a different scanned zone and that cerebral contribution increases with the arrival time of photons. Experiments are conducted at 690 and 830 nm with a time-resolved system consisting of picosecond laser diodes, micro-channel plate photo-multiplier tube and photon counting modules. The hemodynamic response to a short finger tapping stimulus is measured over the motor cortex. Time-resolved absorbance difference maps show that variations in the optical signals are not localized in superficial regions of the head, which testify for their cerebral origin. Furthermore improvements in the detection of cerebral activation is achieved through the increase of variations in absorbance by a factor of almost 5 for time-resolved measurements as compared to non-time-resolved measurements.

  5. Composite solid-state scintillators for neutron detection

    DOEpatents

    Dai, Sheng; Im, Hee-Jung; Pawel, Michelle D.

    2006-09-12

    Applicant's present invention is a composite scintillator for neutron detection comprising a matrix material fabricated from an inorganic sol-gel precursor solution homogeneously doped with a liquid scintillating material and a neutron absorbing material. The neutron absorbing material yields at least one of an electron, a proton, a triton, an alpha particle or a fission fragment when the neutron absorbing material absorbs a neutron. The composite scintillator further comprises a liquid scintillating material in a self-assembled micelle formation homogeneously doped in the matrix material through the formation of surfactant-silica composites. The scintillating material is provided to scintillate when traversed by at least one of an electron, a proton, a triton, an alpha particle or a fission fragment. The scintillating material is configured such that the matrix material surrounds the micelle formation of the scintillating material. The composite scintillator is fabricated and applied as a thin film on substrate surfaces, a coating on optical fibers or as a glass material.

  6. Narrowband Light Detection via Internal Quantum Efficiency Manipulation of Organic Photodiodes

    DOE PAGES

    Armin, A.; Jansen-van Vuuren, R. D.; Kopidakis, N.; ...

    2015-02-01

    Spectrally selective light detection is vital for full-colour and near-infrared (NIR) imaging and machine vision. This is not possible with traditional broadband-absorbing inorganic semiconductors without input filtering, and is yet to be achieved for narrowband absorbing organic semiconductors. We demonstrate the first sub-100 nm full-width-at-half-maximum visible-blind red and NIR photodetectors with state-of-the-art performance across critical response metrics. These devices are based on organic photodiodes with optically thick junctions. Paradoxically, we use broadband-absorbing organic semiconductors and utilize the electro-optical properties of the junction to create the narrowest NIR-band photoresponses yet demonstrated. In this context, these photodiodes outperform the encumbent technology (inputmore » filtered inorganic semiconductor diodes) and emerging technologies such as narrow absorber organic semiconductors or quantum nanocrystals. The design concept allows for response tuning and is generic for other spectral windows. Furthermore, it is materialagnostic and applicable to other disordered and polycrystalline semiconductors.« less

  7. Trace level detection of analytes using artificial olfactometry

    NASA Technical Reports Server (NTRS)

    Lewis, Nathan S. (Inventor); Severin, Erik J. (Inventor); Wong, Bernard (Inventor)

    2002-01-01

    The present invention provides a device for detecting the presence of an analyte, such as for example, a lightweight device, including: a sample chamber having a fluid inlet port for the influx of the analyte; a fluid concentrator in flow communication with the sample chamber wherein the fluid concentrator has an absorbent material capable of absorbing the analyte and capable of desorbing a concentrated analyte; and an array of sensors in fluid communication with the concentrated analyte to be released from the fluid concentrator.

  8. Detecting paraprotein interference on a direct bilirubin assay by reviewing the photometric reaction data.

    PubMed

    García-González, Elena; Aramendía, Maite; González-Tarancón, Ricardo; Romero-Sánchez, Naiara; Rello, Luis

    2017-07-26

    The direct bilirubin (D-Bil) assay on the AU Beckman Coulter instrumentation can be interfered by paraproteins, which may result in spurious D-Bil results. In a previous work, we took advantage of this fact to detect this interference, thus helping with the identification of patients with unsuspected monoclonal gammopathies. In this work, we investigate the possibility to detect interference based on the review of the photometric reactions, regardless of the D-Bil result. The D-Bil assay was carried out in a set of 2164 samples. It included a group of 164 samples with paraproteins (67 of which caused interference on the assay), as well as different groups of samples for which high absorbance background readings could also be expected (i.e. hemolyzed, lipemic, or icteric samples). Photometric reaction data were reviewed and receiver operating characteristics (ROC) curves were used to establish a cut-off for absorbance that best discriminates interference. The best cut-off was 0.0100 for the absorbance at the first photometric point of the complementary wavelength in the blank cuvette. Once the optimal cut-off for probable interference was selected, all samples analyzed in our laboratory that provided absorbance values above this cut-off were further investigated to try to discover paraproteins. During a period of 6 months, we detected 44 samples containing paraproteins, five of which belonged to patients with non-diagnosed monoclonal gammopathies. Review of the photometric reaction data permits the systematic detection of paraprotein interference on the D-Bil AU assay, even for samples for which reasonable results are obtained.

  9. The design of broadband radar absorbing surfaces

    NASA Astrophysics Data System (ADS)

    Suk, Go H.

    1990-09-01

    There has been a growing and widespread interest in radar absorbing material technology. As the name implies, radar absorbing materials or RAM's are coatings whose electric and magnetic properties have been selected to allow the absorption of microwave energy at discrete or broadband frequencies. In military applications low radar cross section (RCS) of a vehicle may be required in order to escape detection while a covert mission is being carried on. These requirements have led to the very low observable or stealth technology that reduces the probability of detection of an aircraft. The design of radar absorbing materials is limited by constraints on the allowable volume and weight of the surface coating, and it is difficult to design a broadband radar absorbing structure in limited volume. This thesis investigates the use of lossy dielectric materials of high dielectric permittivity in multilayer composites for the production of low radar cross section (RCS). The analysis is done by computing the plane wave reflection coefficient at the exterior surface of the composite coating by means of a computer program which selects layer parameters which determine low reflection coefficients for electromagnetic radiation under constraint of limited layer thickness as well as maximum frequency bandwidth.

  10. Step-scan differential Fourier transform infrared photoacoustic spectroscopy (DFTIR-PAS): a spectral deconvolution method for weak absorber detection in the presence of strongly overlapping background absorptions.

    PubMed

    Liu, Lixian; Mandelis, Andreas; Huan, Huiting; Michaelian, Kirk H

    2017-04-01

    The determination of small absorption coefficients of trace gases in the atmosphere constitutes a challenge for analytical air contaminant measurements, especially in the presence of strongly absorbing backgrounds. A step-scan differential Fourier transform infrared photoacoustic spectroscopy (DFTIR-PAS) method was developed to suppress the coherent external noise and spurious photoacoustic (PA) signals caused by strongly absorbing backgrounds. The infrared absorption spectra of acetylene (C2H2) and local air were used to verify the performance of the step-scan DFTIR-PAS method. A linear amplitude response to C2H2 concentrations from 100 to 5000 ppmv was observed, leading to a theoretical detection limit of 5 ppmv. The differential mode was capable of eliminating the coherent noise and dominant background gas signals, thereby revealing the presence of the otherwise hidden C2H2 weak absorption. Thus, the step-scan DFTIR-PAS modality was demonstrated to be an effective approach for monitoring weakly absorbing gases with absorption bands overlapped by strongly absorbing background species.

  11. Thin-Layer Chromatography/Desorption Electrospray Ionization Mass Spectrometry: Investigation of Goldenseal Alkaloids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Berkel, Gary J; Tomkins, Bruce A; Kertesz, Vilmos

    2007-01-01

    Desorption electrospray ionization mass spectrometry was investigated as a means to qualitatively identify and to quantify analytes directly from developed normal-phase thin layer chromatography plates. The atmospheric sampling capillary of a commercial ion trap mass spectrometer was extended to permit sampling and ionization of analytes in bands separated on intact TLC plates (up to 10 cm x 10 cm). A surface positioning software package and the appropriate hardware enabled computer-controlled surface scanning along the length of development lanes or at fixed RF value across the plates versus the stationary desorption electrospray emitter. Goldenseal (Hydrastis canadensis) and related alkaloids and commercialmore » dietary supplements were used as standards and samples. Alkaloid standards and samples were spotted and separated on aluminum- or glass-backed plates using established literature methods. The mass spectral signal levels as a function of desorption spray solvent were investigated with acetonitrile proving superior to methanol. The detection levels (ca. 5 ng each or 14 -28 pmol) in mass spectral full scan mode were determined statistically from the calibration curves (2.5 - 100 pmol) for the standards berberine, palmatine and hydrastinine spotted as a mixture and separated on the plates. Qualitative screening of the major alkaloids present in six different over-the-counter "goldenseal" dietary supplements was accomplished by obtaining full scan mass spectra during surface scans along the development lane in the direction of increasing RF value. In one sample, alkaloids were detected that strongly suggested the presence of at least one additional herb undeclared on the product label. These same data indicated the misidentification of one of the alkaloids in the TLC literature. Quantities of the alkaloids present in two of the samples determined using the mass spectral data were in reasonable agreement with the label values indicating the quantitative ability of the method. The advantage of mass spectral measurements in identifying and quantifying materials within overlapping bands and in providing positive identification for even minor species in a mixture was also demonstrated.« less

  12. Rapid assessment of human amylin aggregation and its inhibition by copper(II) ions by laser ablation electrospray ionization mass spectrometry with ion mobility separation

    DOE PAGES

    Li, Hang; Ha, Emmeline; Donaldson, Robert P.; ...

    2015-09-09

    Native electrospray ionization (ESI) mass spectrometry (MS) is often used to monitor noncovalent complex formation between peptides and ligands. The relatively low throughput of this technique, however, is not compatible with extensive screening. Laser ablation electrospray ionization (LAESI) MS combined with ion mobility separation (IMS) can analyze complex formation and provide conformation information within a matter of seconds. Islet amyloid polypeptide (IAPP) or amylin, a 37-amino acid residue peptide, is produced in pancreatic beta-cells through proteolytic cleavage of its prohormone. Both amylin and its precursor can aggregate and produce toxic oligomers and fibrils leading to cell death in the pancreasmore » that can eventually contribute to the development of type 2 diabetes mellitus. The inhibitory effect of the copper(II) ion on amylin aggregation has been recently discovered, but details of the interaction remain unknown. Finding other more physiologically tolerated approaches requires large scale screening of potential inhibitors. In this paper, we demonstrate that LAESI-IMS-MS can reveal the binding stoichiometry, copper oxidation state, and the dissociation constant of human amylin–copper(II) complex. The conformations of hIAPP in the presence of copper(II) ions were also analyzed by IMS, and preferential association between the β-hairpin amylin monomer and the metal ion was found. The copper(II) ion exhibited strong association with the —HSSNN– residues of the amylin. In the absence of copper(II), amylin dimers were detected with collision cross sections consistent with monomers of β-hairpin conformation. When copper(II) was present in the solution, no dimers were detected. Thus, the copper(II) ions disrupt the association pathway to the formation of β-sheet rich amylin fibrils. Using LAESI-IMS-MS for the assessment of amylin–copper(II) interactions demonstrates the utility of this technique for the high-throughput screening of potential inhibitors of amylin oligomerization and fibril formation. Finally and more generally, this rapid technique opens the door for high-throughput screening of potential inhibitors of amyloid protein aggregation.« less

  13. Detection of follicular transport of lidocaine and metabolism in adipose tissue in pig ear skin by DESI mass spectrometry imaging.

    PubMed

    D'Alvise, Janina; Mortensen, Rasmus; Hansen, Steen H; Janfelt, Christian

    2014-06-01

    Desorption electrospray ionization (DESI) mass spectrometry imaging is demonstrated as a detection technique for penetration experiments of drugs in skin. Lidocaine ointment was used as the model compound in ex vivo experiments with whole pig ears as the skin model. Follicular transport of lidocaine into the deeper skin layers is demonstrated for the first time. Furthermore, metabolism of lidocaine to 3-OH-lidocaine was observed in subcutaneous tissue as well as in lobules of white adipose tissue surrounding the hair follicles. These results suggest that it is advantageous to use full thickness skin, including subcutaneous tissue, for skin metabolism studies.

  14. Biotin-Avidin ELISA Detection of Grapevine Fanleaf Virus in the Vector Nematode Xiphinema index.

    PubMed

    Esmenjaud, D; Walter, B; Minot, J C; Voisin, R; Cornuet, P

    1993-09-01

    The value of biotin-avidin (B-A) ELISA for the detection of grapevine fanleaf virus (GFLV) in Xiphinema was estimated with field populations and greenhouse subpopulations. Samples consisted of increasing numbers of adults ranging from 1 to 64 in multiples of two. Tests with virus-free X. index populations reared on grapevine and fig plants as negative controls did not reveal a noticeable effect of the host plant. ELISA absorbances of virus-free X. index samples were greater than corresponding absorbances of X. pachtaicum samples. Differences occurred between two X. index field populations from GFLV-infected grapevines in Champagne and Languedoc. In most tests, 1-, 2-, 4-, and 8-nematode samples of virus-free and virus-infected populations, respectively, could not be separated. Consequently, B-A ELISA was not a reliable method for GFLV detection in samples of less than 10 X. index adults, but comparison of the absorbances obtained with increasing numbers may allow differentiation of the viral infectious potential of several populations.

  15. Use of an Open Port Sampling Interface Coupled to Electrospray Ionization for the On-Line Analysis of Organic Aerosol Particles

    NASA Astrophysics Data System (ADS)

    Swanson, Kenneth D.; Worth, Anne L.; Glish, Gary L.

    2018-02-01

    A simple design for an open port sampling interface coupled to electrospray ionization (OPSI-ESI) is presented for the analysis of organic aerosols. The design uses minimal modifications to a Bruker electrospray (ESI) emitter to create a continuous flow, self-aspirating open port sampling interface. Considerations are presented for introducing aerosol to the open port sampling interface including aerosol gas flow and solvent flow rates. The device has been demonstrated for use with an aerosol of nicotine as well as aerosol formed in the pyrolysis of biomass. Upon comparison with extractive electrospray ionization (EESI), this device has similar sensitivity with increased reproducibility by nearly a factor of three. The device has the form factor of a standard Bruker/Agilent ESI emitter and can be used without any further instrument modifications.

  16. Flow-Cell-Induced Dispersion in Flow-through Absorbance Detection Systems: True Column Effluent Peak Variance.

    PubMed

    Dasgupta, Purnendu K; Shelor, Charles Phillip; Kadjo, Akinde Florence; Kraiczek, Karsten G

    2018-02-06

    Following a brief overview of the emergence of absorbance detection in liquid chromatography, we focus on the dispersion caused by the absorbance measurement cell and its inlet. A simple experiment is proposed wherein chromatographic flow and conditions are held constant but a variable portion of the column effluent is directed into the detector. The temporal peak variance (σ t,obs 2 ), which increases as the flow rate (F) through the detector decreases, is found to be well-described as a quadratic function of 1 / F . This allows the extrapolation of the results to zero residence time in the detector and thence the determination of the true variance of the peak prior to the detector (this includes contribution of all preceding components). This general approach should be equally applicable to detection systems other than absorbance. We also experiment where the inlet/outlet system remains the same but the path length is varied. This allows one to assess the individual contributions of the cell itself and the inlet/outlet system.to the total observed peak. The dispersion in the cell itself has often been modeled as a flow-independent parameter, dependent only on the cell volume. Except for very long path/large volume cells, this paradigm is simply incorrect.

  17. DIFFERENTIATION OF AURANTII FRUCTUS IMMATURUS AND FRUCTUS PONICIRI TRIFOLIATAE IMMATURUS BY FLOW-INJECTION WITH ULTRAVIOLET SPECTROSCOPIC DETECTION AND PROTON NUCLEAR MAGNETIC RESONANCE USING PARTIAL LEAST-SQUARES DISCRIMINANT ANALYSIS.

    PubMed

    Zhang, Mengliang; Zhao, Yang; Harrington, Peter de B; Chen, Pei

    2016-03-01

    Two simple fingerprinting methods, flow-injection coupled to ultraviolet spectroscopy and proton nuclear magnetic resonance, were used for discriminating between Aurantii fructus immaturus and Fructus poniciri trifoliatae immaturus . Both methods were combined with partial least-squares discriminant analysis. In the flow-injection method, four data representations were evaluated: total ultraviolet absorbance chromatograms, averaged ultraviolet spectra, absorbance at 193, 205, 225, and 283 nm, and absorbance at 225 and 283 nm. Prediction rates of 100% were achieved for all data representations by partial least-squares discriminant analysis using leave-one-sample-out cross-validation. The prediction rate for the proton nuclear magnetic resonance data by partial least-squares discriminant analysis with leave-one-sample-out cross-validation was also 100%. A new validation set of data was collected by flow-injection with ultraviolet spectroscopic detection two weeks later and predicted by partial least-squares discriminant analysis models constructed by the initial data representations with no parameter changes. The classification rates were 95% with the total ultraviolet absorbance chromatograms datasets and 100% with the other three datasets. Flow-injection with ultraviolet detection and proton nuclear magnetic resonance are simple, high throughput, and low-cost methods for discrimination studies.

  18. Polysialylated N-Glycans Identified in Human Serum Through Combined Developments in Sample Preparation, Separations and Electrospray ionization-mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kronewitter, Scott R.; Marginean, Ioan; Cox, Jonathan T.

    The N-glycan diversity of human serum glycoproteins, i.e. the human blood serum N-glycome, is complex due to the range of glycan structures potentially synthesizable by human glycosylation enzymes. The reported glycome, however, is limited by methods of sample preparation, available analytical platforms, e.g., based upon electrospray ionization-mass spectrometry (ESI-MS), and software tools for data analysis. In this report, several improvements have been implemented in sample preparation and analysis to extend ESI-MS glycan characterization and to provide an improved view of glycan diversity. Sample preparation improvements include acidified, microwave-accelerated, PNGase F N-glycan release, and sodium borohydride reduction were optimized to improvemore » quantitative yields and conserve the number of glycoforms detected. Two-stage desalting (during solid phase extraction and on the analytical column) increased the sensitivity by reducing analyte signal division between multiple reducing-end-forms or cation adducts. On-line separations were improved by using extended length graphitized carbon columns and adding TFA as an acid modifier to a formic acid/reversed phase gradient which provides additional resolving power and significantly improved desorption of both large and heavily sialylated glycans. To improve MS sensitivity and provide gentler ionization conditions at the source-MS interface, subambient pressure ionization with nanoelectrospray (SPIN) has been utilized. When method improvements are combined together with the Glycomics Quintavariate Informed Quantification (GlyQ-IQ) recently described1 these technologies demonstrate the ability to significantly extend glycan detection sensitivity and provide expanded glycan coverage. We demonstrate application of these advances in the context of the human serum glycome, and for which our initial observations include detection of a new class of heavily sialylated N-glycans, including polysialylated N-glycans.« less

  19. Artificial sweeteners--a recently recognized class of emerging environmental contaminants: a review.

    PubMed

    Lange, Frank T; Scheurer, Marco; Brauch, Heinz-J

    2012-07-01

    An overview is given of existing trace analytical methods for the determination of seven popular artificial sweeteners [acesulfame (ACE), aspartame, cyclamate (CYC), neotame, neohesperidine dihydrochalcone, saccharin (SAC), and sucralose (SUC)] from aqueous environmental samples. Liquid chromatography-electrospray ionization tandem mass spectrometry and liquid chromatography-electrospray ionization high-resolution mass spectrometry are the methods most widely applied, either directly or after solid-phase extraction. Limits of detection and limits of quantification down to the low nanogram per liter range can be achieved. ACE, CYC, SAC, and SUC were detected in wastewater treatment plants in high microgram per liter concentrations. Per capita loads of individual sweeteners can vary within a wide range depending on their use in different countries. Whereas CYC and SAC are usually degraded by more than 90% during wastewater treatment, ACE and SUC pass through wastewater treatment plants mainly unchanged. This suggests their use as virtually perfect markers for the study of the impact of wastewater on source waters and drinking waters. In finished water of drinking water treatment plants using surface-water-influenced source water, ACE and SUC were detected in concentrations up to 7 and 2.4 μg/L, respectively. ACE was identified as a precursor of oxidation byproducts during ozonation, resulting in an aldehyde intermediate and acetic acid. Although the concentrations of ACE and SUC are among the highest measured for anthropogenic trace pollutants found in surface water, groundwater, and drinking water, the levels are at least three orders of magnitude lower than organoleptic threshold values. However, ecotoxicology studies are scarce and have focused on SUC. Thus, further research is needed both on identification of transformation products and on the ecotoxicological impact of artificial sweeteners and their transformation products.

  20. High-Resolution Electrospray Ionization Mass Spectrometry Analysis of Water- Soluble Organic Aerosols Collected with a Particle into Liquid Sampler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bateman, Adam P.; Nizkorodov, Serguei; Laskin, Julia

    2010-10-01

    This work demonstrates the utility of a particle-into-liquid sampler (PILS) a technique traditionally used for identification of inorganic ions present in ambient or laboratory aerosols for the analysis of water soluble organic aerosol (OA) using high resolution electrospray ionization mass spectrometry (HR ESI-MS). Secondary organic aerosol (SOA) was produced from 0.5 ppm mixing ratios of limonene and ozone in a 5 m3 Teflon chamber. SOA was collected simultaneously using a traditional filter sampler and a PILS. The filter samples were later extracted with either water or acetonitrile, while the aqueous PILS samples were analyzed directly. In terms of peak intensities,more » types of detectable compounds, average O:C ratios, and organic mass to organic carbon ratios, the resulting high resolution mass spectra were essentially identical for the PILS and filter based samples. SOA compounds extracted from both filter/acetonitrile extraction and PILS/water extraction accounted for >95% of the total ion current in ESI mass spectra. This similarity was attributed to high solubility of limonene SOA in water. In contrast, significant differences in detected ions and peak abundances were observed for pine needle biomass burning organic aerosol (BBOA) collected with PILS and filter sampling. The water soluble fraction of BBOA is considerably smaller than for SOA, and a number of unique peaks were detectable only by the filter/acetonitrile method. The combination of PILS collection with HR-ESI-MS analysis offers a new approach for molecular analysis of the water-soluble organic fraction in biogenic SOA, aged photochemical smog, and BBOA.« less

  1. Secondary electrospray ionization-mass spectrometry and a novel statistical bioinformatic approach identifies a cancer-related profile in exhaled breath of breast cancer patients: a pilot study.

    PubMed

    Martinez-Lozano Sinues, Pablo; Landoni, Elena; Miceli, Rosalba; Dibari, Vincenza F; Dugo, Matteo; Agresti, Roberto; Tagliabue, Elda; Cristoni, Simone; Orlandi, Rosaria

    2015-09-21

    Breath analysis represents a new frontier in medical diagnosis and a powerful tool for cancer biomarker discovery due to the recent development of analytical platforms for the detection and identification of human exhaled volatile compounds. Statistical and bioinformatic tools may represent an effective complement to the technical and instrumental enhancements needed to fully exploit clinical applications of breath analysis. Our exploratory study in a cohort of 14 breast cancer patients and 11 healthy volunteers used secondary electrospray ionization-mass spectrometry (SESI-MS) to detect a cancer-related volatile profile. SESI-MS full-scan spectra were acquired in a range of 40-350 mass-to-charge ratio (m/z), converted to matrix data and analyzed using a procedure integrating data pre-processing for quality control, and a two-step class prediction based on machine-learning techniques, including a robust feature selection, and a classifier development with internal validation. MS spectra from exhaled breath showed an individual-specific breath profile and high reciprocal homogeneity among samples, with strong agreement among technical replicates, suggesting a robust responsiveness of SESI-MS. Supervised analysis of breath data identified a support vector machine (SVM) model including 8 features corresponding to m/z 106, 126, 147, 78, 148, 52, 128, 315 and able to discriminate exhaled breath from breast cancer patients from that of healthy individuals, with sensitivity and specificity above 0.9.Our data highlight the significance of SESI-MS as an analytical technique for clinical studies of breath analysis and provide evidence that our noninvasive strategy detects volatile signatures that may support existing technologies to diagnose breast cancer.

  2. Rapid separation and identification of anthocyanins from flowers of Viola yedoensis and V. prionantha by high-performance liquid chromatography-photodiode array detection-electrospray ionisation mass spectrometry.

    PubMed

    Zhang, Jie; Wang, Liang-Sheng; Gao, Jin-Ming; Xu, Yan-Jun; Li, Lian-Fang; Li, Chong-Hui

    2012-01-01

    Anthocyanins are important plant secondary metabolites. They show strong antioxidant activities and have potential as anti-cancer agents. Viola yedoensis and V. prionantha are traditional Chinese medicines and ornamental plants. However, the anthocyanin compositions of these two species are still unresolved. To develop a rapid and reliable high-performance liquid chromatography (HPLC) method for the separation and identification of anthocyanins from V. yedoensis and V. prionantha. Samples were extracted in methanol-water-formic acid-TFA (70:27:2:1, v/v). HPLC analysis was done on a C(18) column (TSK-GEL ODS-80Ts: 150 × 4.6 mm i.d.). Four solvent systems were tested to optimise the separation of anthocyanins using different gradient separation systems. HPLC-photodiode array detection (DAD) coupled to electrospray ionisation mass spectrometry (ESI-MS) was used to carry out the comprehensive characterisation of anthocyanins. Fourteen anthocyanins were characterised within 40 min with satisfactory peak resolution by a gradient composed of 10% aqueous formic acid and formic acid-acetonitrile-water (10:40:50, v/v). The calibration curve showed an excellent linear regression (r(2)  = 0.9995) and low intra- and inter-day variations (RSD < 3.67%). The detected anthocyanins derived from Dp, Cy, Pt, Mv and Pn, could be divided into three groups: non-acylated glycosides, acetylglycosides and coumaroylglycosides. Anthocyanins distribution exhibited remarkable differences in aglycone levels and acylation patterns. The optimised method was successfully applied for the analysis of 14 anthocyanins from V. yedoensis and V. prionantha. The identification of anthocyanin constitutions is valuable for breeding and will open up new prospects for their medicinal application. Copyright © 2011 John Wiley & Sons, Ltd.

  3. Molecular characterization of organosulfates in organic aerosols from Shanghai and Los Angeles urban areas by nanospray-desorption electrospray ionization high-resolution mass spectrometry.

    PubMed

    Tao, Shikang; Lu, Xiaohui; Levac, Nicole; Bateman, Adam P; Nguyen, Tran B; Bones, David L; Nizkorodov, Sergey A; Laskin, Julia; Laskin, Alexander; Yang, Xin

    2014-09-16

    Fine aerosol particles in the urban areas of Shanghai and Los Angeles were collected on days that were characterized by their stagnant air and high organic aerosol concentrations. They were analyzed by nanospray-desorption electrospray ionization mass spectrometry with high mass resolution (m/Δm = 100,000). Solvent mixtures of acetonitrile and water and acetonitrile and toluene were used to extract and ionize polar and nonpolar compounds, respectively. A diverse mixture of oxygenated hydrocarbons, organosulfates, organonitrates, and organics with reduced nitrogen were detected in the Los Angeles sample. A majority of the organics in the Shanghai sample were detected as organosulfates. The dominant organosulfates that were detected at two locations have distinctly different molecular characteristics. Specifically, the organosulfates in the Los Angeles sample were dominated by biogenic products, while the organosulfates of a yet unknown origin found in the Shanghai sample had distinctive characteristics of long aliphatic carbon chains and low degrees of oxidation and unsaturation. The use of the acetonitrile and toluene solvent facilitated the observation of this type of organosulfates, which suggests that they could have been missed in previous studies that relied on sample extraction using common polar solvents. The high molecular weight and low degree of unsaturation and oxidization of the uncommon organosulfates suggest that they may act as surfactants and plausibly affect the surface tension and hygroscopicity of atmospheric particles. We propose that direct esterification of carbonyl or hydroxyl compounds by sulfates or sulfuric acid in the liquid phase could be the formation pathway of these special organosulfates. Long-chain alkanes from vehicle emissions might be their precursors.

  4. Trace level determination of selected organophosphorus pesticides and their degradation products in environmental air samples by liquid chromatography-positive ion electrospray tandem mass spectrometry.

    PubMed

    Raina, Renata; Sun, Lina

    2008-05-01

    This paper describes a new analytical method for determination of organophosphorus pesticides (OPs) along with their degradation products involving liquid chromatography (LC) positive ion electrospray (ESI+) tandem mass spectrometry (MS-MS) with selective reaction monitoring (SRM). Chromatography was performed on a Gemini C6-Phenyl (150 mmx2.0 mm, 3 microm) with a gradient elution using water-methanol with 0.1% formic acid, 2 mM ammonium acetate mobile phase at a flow rate of 0.2 mL min(-1). The LC separation and MS/MS operating conditions were optimized with a total analysis time less than 40 minutes. Method detection limits of 0.1-5 microg L(-1) for selected organophosphorus pesticides (OP), OP oxon degradation products, and other degradation products: 3,5,6-trichloro-2-pyridinol (TCP); 2-isopropyl-6-methyl-4-pyrimidol (IMP); and diethyl phosphate (DEP). Some OPs such as fenchlorphos are less sensitive (MDL 30 microg L(-1)). Calibration curves were linear with coefficients of correlation better than 0.995. A three-point identification approach was adopted with area from first selective reaction monitoring (SRM) transition used for quantitative analysis, while a second SRM transition along with the ratio of areas obtained from the first to second transition are used for confirmation with sample tolerance established by the relative standard deviation of the ratio obtained from standards. This new method permitted the first known detection of OP oxon degradation products including chlorpyrifos oxon at Bratt's Lake, SK and diazinon oxon and malathion oxon at Abbotsford, BC in atmospheric samples. Atmospheric detection limits typically ranged from 0.2-10 pg m(-3).

  5. Determination of interglycosidic linkages in O-glycosyl flavones by high-performance liquid chromatography/photodiode-array detection coupled to electrospray ionization ion trap mass spectrometry. Its application to Tetragonula carbonaria honey from Australia.

    PubMed

    Truchado, Pilar; Vit, Patricia; Heard, Tim A; Tomás-Barberán, Francisco A; Ferreres, Federico

    2015-05-30

    Tetragonula carbonaria pot-honeys are highly valued as a food source and for their biological activities in Australia, and there is a growing interest to know its composition. Phenolic metabolites, which could be related to their beneficial properties, have not been studied in depth yet. Mass spectrometry (MS) coupled to liquid chromatography (LC) is an advanced technique for the study of complex flavonoids present in difficult food matrices that hampers their isolation and purification. This allows the tentative characterization of diglycosides/triglycosides establishing the position of the O-glycosylation on the sugar moiety by the study of the MS data in T. carbonaria pot-honeys from Australia. Their spectra obtained by high-performance liquid chromatography/photodiode-array detection/electrospray ionization ion trap mass spectrometry (HPLC/DAD/ESI-MS(n) ) revealed for the first time 19 quercetin, kaempferol and isorhamnetin O-glycosides. These compounds were clustered in flavonoid triglycosides, diglycosides and monoglycosides. The first cluster contained one flavonoid trihexoside, two -3-O-(2-hexosyl, 6-rhamnosyl)hexosides and their isomers and two -3-O-(2,6-di-rhamnosyl)hexosides. In the second cluster, eleven flavonoid diglycosides such as three -3-O-(2-hexosyl)hexosides, four -3-O-(2-rhamnosyl)hexosides and one -3-O-(6-rhamnosyl)hexoside as well as two -3-O-(2-pentosyl)hexosides and one tentative -3-O-(3-pentosyl)hexoside were detected. In the monoglycoside group, only one flavonoid -3-O-hexoside was identified. The occurrence of this large number of flavonoid glycosides could be due to the low glucosidase activity previously reported in stingless bee honey. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Laser-ablation electrospray ionization mass spectrometry with ion mobility separation reveals metabolites in the symbiotic interactions of soybean roots and rhizobia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stopka, Sylwia A.; Agtuca, Beverly J.; Koppenaal, David W.

    Technologies enabling in situ metabolic profiling of living plant systems are invaluable for understanding physiological processes and could be used for rapid phenotypic screening (e.g., to produce plants with superior biological nitrogen fixing ability). The symbiotic interaction between legumes and nitrogen-fixing soil bacteria results in a specialized plant organ (i.e., root nodule), where the exchange of nutrients between host and endosymbiont occurs. Laser ablation electrospray ionization mass spectrometry (LAESI-MS) is a method that can be performed under ambient conditions requiring minimal sample preparation. Here, we employed LAESI-MS to explore the well-characterized symbiosis between soybean (Glycine max L. Merr.) and itsmore » compatible symbiont, Bradyrhizobium japonicum. The utilization of ion mobility separation (IMS) improved the molecular coverage, selectivity, and identification of the detected biomolecules. Specifically, incorporation of IMS resulted in an increase of 153 detected metabolites in the nodule samples. The data presented demonstrates the advantages of using LAESI-IMS-MS for the rapid analysis of intact root nodules, uninfected root segments, and free-living rhizobia. Untargeted pathway analysis revealed several metabolic processes within the nodule (e.g., zeatin, riboflavin, and purine synthesis). Compounds specific to the uninfected root and bacteria were also detected. Lastly, we performed depth-profiling of intact nodules to reveal the location of metabolites to the cortex and inside the infected region, and lateral profiling of sectioned nodules confirmed these molecular distributions. Our results established the feasibility of LAESI-IMS-MS for the analysis and spatial mapping of plant tissues, with its specific demonstration to improve our understanding of the soybean-rhizobial symbiosis.« less

  7. A SURVEY OF METAL LINES AT HIGH-REDSHIFT. I. SDSS ABSORPTION LINE STUDIES- THE METHODOLOGY AND FIRST SEARCH RESULTS FOR O VI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frank, S.; Mathur, S.; Pieri, M.

    2010-09-15

    We report the results of a systematic search for signatures of metal lines in quasar spectra of the Sloan Digital Sky Survey (SDSS) data release 3 (DR3), focusing on finding intervening absorbers via detection of their O VI doublet. Here, we present the search algorithm and criteria for distinguishing candidates from spurious Ly{alpha} forest lines. In addition, we compare our findings with simulations of the Ly{alpha} forest in order to estimate the detectability of O VI doublets over various redshift intervals. We have obtained a sample of 1756 O VI doublet candidates with rest-frame equivalent width (EW) {>=}0.05 A inmore » 855 active galactic nuclei spectra (out of 3702 objects with redshifts in the accessible range for O VI detection). This sample is further subdivided into three groups according to the likelihood of being real and the potential for follow-up observation of the candidate. The group with the cleanest and most secure candidates is comprised of 145 candidates. Sixty-nine of these reside at a velocity separation {>=}5000 km s{sup -1} from the QSO and can therefore be classified tentatively as intervening absorbers. Most of these absorbers have not been picked up by earlier, automated QSO absorption line detection algorithms. This sample increases the number of known O VI absorbers at redshifts beyond z{sub abs{>=}} 2.7 substantially.« less

  8. AMS of 93Zr: Passive absorber versus gas-filled magnet

    NASA Astrophysics Data System (ADS)

    Hain, Karin; Deneva, Boyana; Faestermann, Thomas; Fimiani, Leticia; Gómez-Guzmán, José Manuel; Koll, Dominik; Korschinek, Gunther; Ludwig, Peter; Sergeyeva, Victoria; Thiollay, Nicolas

    2018-05-01

    Two different isobar separation techniques were tested for the detection of the long-lived fission product 93Zr (T1/2 = 1.64 · 106 a) using Accelerator Mass Spectrometry (AMS), i.e. a passive absorber and a gas-filled magnet, respectively. Both techniques were used in combination with a Time-of-Flight path for the identification of the stable neighboring isotopes 92Zr and 94Zr. The passive absorber was represented by a stack of silicon nitride foils for high flexibility regarding the thickness for optimal isobar separation. Ion beams with a large variety of energies, between 80 and 180 MeV, were provided for this experiment by the tandem accelerator at the Maier-Leibnitz Laboratory in Garching, Germany. With these beams, the stopping powers of 93Zr and 93Nb as a function of energy were determined experimentally and compared to the results obtained with the simulation program SRIM. Considerable discrepancies regarding the energy dependence of the two stopping power curves relative to each other were found. The lowest detection limit for 93Zr achieved with the passive absorber setup was 93Zr/Zr = 1 · 10-10. In comparison, by optimizing the gas-filled magnet set-up, 93Nb was suppressed by around six orders of magnitude and a detection limit of 93Zr/Zr = 5 · 10-11 was obtained. To our knowledge, these results represent the lowest detection limit achieved for 93Zr until now.

  9. Phase I metabolism of the carbazole derived synthetic cannabinoids EG-018, EG-2201 and MDMB-CHMCZCA and detection in human urine samples.

    PubMed

    Mogler, Lukas; Franz, Florian; Wilde, Maurice; Huppertz, Laura M; Halter, Sebastian; Angerer, Verena; Moosmann, Bjoern; Auwärter, Volker

    2018-05-04

    Synthetic cannabinoids (SCs) are a structurally diverse class of new psychoactive substances. Most SCs used for recreational purposes are based on indole or indazole core structures. EG-018 (naphthalen-1-yl(9-pentyl-9H-carbazol-3-yl)methanone), EG-2201 ((9-(5-fluoropentyl)-9H-carbazol-3-yl)(naphthalen-1-yl)methanone) and MDMB-CHMCZCA (methyl 2-(9-(cyclohexylmethyl)-9H-carbazole-3-carboxamido)-3,3-dimethylbutanoate) are three representatives of a structural subclass of SCs, characterized by a carbazole core system. In vitro and in vivo phase I metabolism studies were conducted to identify the most suitable metabolites for the detection of these substances in urine screening. Detection and characterization of metabolites were performed by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) and liquid chromatography-electrospray ionization-quadrupole time-of-flight mass spectrometry (LC-ESI-QToF-MS). Eleven in vivo metabolites were detected in urine samples positive for metabolites of EG-018 (n=8). A hydroxypentyl metabolite, most probably the 4-hydroxypentyl isomer, and an N-dealkylated metabolite mono-hydroxylated at the carbazole core system were most abundant. In vitro studies of EG-018 and EG-2201 indicated that oxidative defluorination of the 5-fluoropentyl side chain of EG-2201 as well as dealkylation led to common metabolites with EG-018. This has to be taken into account for interpretation of analytical findings. A differentiation between EG-018 and EG-2201 (n=1) uptake is possible by the detection of compound-specific in vivo phase I metabolites evaluated in this study. Out of 30 metabolites detected in urine samples of MDMB-CHMCZCA users (n=20), one metabolite mono-hydroxylated at the cyclohexyl methyl tail is considered the most suitable compound-specific consumption marker while a biotransformation product of mono-hydroxylation in combination with hydrolysis of the terminal methyl ester function provides best sensitivity due to its high abundance. This article is protected by copyright. All rights reserved.

  10. Chlorogenic acid versus amaranth's caffeoylisocitric acid - Gut microbial degradation of caffeic acid derivatives.

    PubMed

    Vollmer, Maren; Schröter, David; Esders, Selma; Neugart, Susanne; Farquharson, Freda M; Duncan, Sylvia H; Schreiner, Monika; Louis, Petra; Maul, Ronald; Rohn, Sascha

    2017-10-01

    The almost forgotten crop amaranth has gained renewed interest in recent years due to its immense nutritive potential. Health beneficial effects of certain plants are often attributed to secondary plant metabolites such as phenolic compounds. As these compounds undergo significant metabolism after consumption and are in most cases not absorbed very well, it is important to gain knowledge about absorption, biotransformation, and further metabolism in the human body. Whilst being hardly found in other edible plants, caffeoylisocitric acid represents the most abundant low molecular weight phenolic compound in many leafy amaranth species. Given that this may be a potentially bioactive compound, gastrointestinal microbial degradation of this substance was investigated in the present study by performing in vitro fermentation tests using three different fecal samples as inocula. The (phenolic) metabolites were analyzed using high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Furthermore, quantitative polymerase chain reaction (qPCR) analyses were carried out to study the influence on the microbiome and its composition. The in vitro fermentations led to different metabolite profiles depending on the specific donor. For example, the metabolite 3-(4-hydroxyphenyl)propionic acid was observed in one fermentation as the main metabolite, whereas 3-(3-hydroxyphenyl)propionic acid was identified in the other fermentations as important. A significant change in selected microorganisms of the gut microbiota however was not detected. In conclusion, caffeoylisocitric acid from amaranth, which is a source of several esterified phenolic acids in addition to chlorogenic acid, can be metabolized by the human gut microbiota, but the metabolites produced vary between individuals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Laser micromachined isoelectric focusing devices on polymer substrate for electrospray mass spectrometry

    NASA Astrophysics Data System (ADS)

    Lin, Yuehe; Wen, Jenny; Fan, Xiang; Matson, Dean W.; Smith, Richard D.

    1999-08-01

    A microfabricated device for isoelectric focusing (IEF) incorporating an optimized electrospray ionization (ESI) tip was constructed on polycarbonate plates using a laser micromachining technique. The separation channels on an IEF chip were 16 cm long, 50 micrometers wide and 30 micrometers deep. Electrical potentials used for IEF focusing and electrospray were applied through platinum electrodes placed in the buffer reservoirs, and which were isolated from the separation channel by molecular porous membranes. On-line ESI produced directly from a sharp `tip' on the microchip was evaluated. The results indicate that this design can produce a stable electrospray that is further improved and made more flexible with the assistance of sheath gas and sheath liquid. Error analysis of the spectral data shows that the standard deviation in signal intensity for an analyte peak was less than approximately 5% over 3 hours. The production of stable electrosprays directly from microchip IEF devices represents a step towards easily- fabricated microanalytical devices. IEF separations of protein mixtures were demonstrated for uncoated polycarbonate microchips. On-line IEF/ESI-MS was demonstrated using the microfabricated chip with an ion-trap ESI mass spectrometer for characterization of protein mixtures.

  12. Obtaining Thickness-Limited Electrospray Deposition for 3D Coating.

    PubMed

    Lei, Lin; Kovacevich, Dylan A; Nitzsche, Michael P; Ryu, Jihyun; Al-Marzoki, Kutaiba; Rodriguez, Gabriela; Klein, Lisa C; Jitianu, Andrei; Singer, Jonathan P

    2018-04-04

    Electrospray processing utilizes the balance of electrostatic forces and surface tension within a charged spray to produce charged microdroplets with a narrow dispersion in size. In electrospray deposition, each droplet carries a small quantity of suspended material to a target substrate. Past electrospray deposition results fall into two major categories: (1) continuous spray of films onto conducting substrates and (2) spray of isolated droplets onto insulating substrates. A crossover regime, or a self-limited spray, has only been limitedly observed in the spray of insulating materials onto conductive substrates. In such sprays, a limiting thickness emerges, where the accumulation of charge repels further spray. In this study, we examined the parametric spray of several glassy polymers to both categorize past electrospray deposition results and uncover the critical parameters for thickness-limited sprays. The key parameters for determining the limiting thickness were (1) field strength and (2) spray temperature, related to (i) the necessary repulsive field and (ii) the ability for the deposited materials to swell in the carrier solvent vapor and redistribute charge. These control mechanisms can be applied to the uniform or controllably-varied microscale coating of complex three-dimensional objects.

  13. Electrospraying of polymer solutions: Study of formulation and process parameters.

    PubMed

    Smeets, Annelies; Clasen, Christian; Van den Mooter, Guy

    2017-10-01

    Over the past decade, electrospraying has proven to be a promising method for the preparation of amorphous solid dispersions, an established formulation strategy to improve the oral bioavailability of poorly soluble drug compounds. Due to the lack of fundamental knowledge concerning adequate single nozzle electrospraying conditions, a trial-and-error approach is currently the only option. The objective of this paper is to study/investigate the influence of the different formulation and process parameters, as well as their interplay, on the formation of a stable cone-jet mode as a prerequisite for a reproducible production of monodisperse micro- and nanoparticles. To this purpose, different polymers commonly used in the formulation of solid dispersions were electrosprayed to map out the workable parameter ranges of the process. The experiments evaluate the importance of the experimental parameters as flow rate, electric potential difference and the distance between the tip of the nozzle and collector. Based on this, the type of solvent and the concentration of the polymer solutions, along with their viscosity and conductivity, were identified as determinative formulation parameters. This information is of utmost importance to rationally design further electrospraying methods for the preparation of amorphous solid dispersions. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Laser Calorimetry Spectroscopy for ppm-level Dissolved Gas Detection and Analysis

    PubMed Central

    K. S., Nagapriya; Sinha, Shashank; R., Prashanth; Poonacha, Samhitha; Chaudhry, Gunaranjan; Bhattacharya, Anandaroop; Choudhury, Niloy; Mahalik, Saroj; Maity, Sandip

    2017-01-01

    In this paper we report a newly developed technique – laser calorimetry spectroscopy (LCS), which is a combination of laser absorption spectroscopy and calorimetry - for the detection of gases dissolved in liquids. The technique involves determination of concentration of a dissolved gas by irradiating the liquid with light of a wavelength where the gas absorbs, and measuring the temperature change caused by the absorbance. Conventionally, detection of dissolved gases with sufficient sensitivity and specificity was done by first extracting the gases from the liquid and then analyzing the gases using techniques such as gas chromatography. Using LCS, we have been able to detect ppm levels of dissolved gases without extracting them from the liquid. In this paper, we show the detection of dissolved acetylene in transformer oil in the mid infrared (MIR) wavelength (3021 nm) region. PMID:28218304

  15. Laser Calorimetry Spectroscopy for ppm-level Dissolved Gas Detection and Analysis.

    PubMed

    K S, Nagapriya; Sinha, Shashank; R, Prashanth; Poonacha, Samhitha; Chaudhry, Gunaranjan; Bhattacharya, Anandaroop; Choudhury, Niloy; Mahalik, Saroj; Maity, Sandip

    2017-02-20

    In this paper we report a newly developed technique - laser calorimetry spectroscopy (LCS), which is a combination of laser absorption spectroscopy and calorimetry - for the detection of gases dissolved in liquids. The technique involves determination of concentration of a dissolved gas by irradiating the liquid with light of a wavelength where the gas absorbs, and measuring the temperature change caused by the absorbance. Conventionally, detection of dissolved gases with sufficient sensitivity and specificity was done by first extracting the gases from the liquid and then analyzing the gases using techniques such as gas chromatography. Using LCS, we have been able to detect ppm levels of dissolved gases without extracting them from the liquid. In this paper, we show the detection of dissolved acetylene in transformer oil in the mid infrared (MIR) wavelength (3021 nm) region.

  16. Electrical and optical performance of mid-wavelength infrared InAsSb heterostructure detectors

    NASA Astrophysics Data System (ADS)

    Gomółka, Emilia; Kopytko, Małgorzata; Michalczewski, Krystian; Kubiszyn, Łukasz; Kebłowski, Artur; Gawron, Waldemar; Martyniuk, Piotr; Piotrowski, Józef; Rutkowski, Jarosław

    2017-10-01

    In this work we investigate the high-operating temperature performance of InAsSb/AlSb heterostructure detectors with cut-off wavelengths near 5 μm at 230 K. The devices have been fabricated with different type of the absorbing layer: nominally undoped absorber, and both n- and p-type doped. The results show that the device performance strongly depends on absorber layer doping. Generally, p-type absorber provides higher values of current responsivity than n-type absorber, but at the same time also higher values of dark current. The device with nominally undoped absorbing layer shows moderate values of both current responsivity and dark current. Resulting detectivities D° of non-immersed devices varies from 2×109 to 7×109 cmHz1/2/W at 230 K, which is easily achievable with a two stage thermoelectric cooler.

  17. Finding a Single Molecule in a Haystack: Laser Spectroscopy of Solids from Sqrt. N to N = 1

    DTIC Science & Technology

    1991-01-02

    low-temperature inhomogeneously broadened 0-0 S, +- S electronic transition of pentacene dopant molecules in p-terphenyl crystals have yielded both (1...absorber, single-miolecule detection, or SMDI) wvould provide a-- useful tool for the study of local host-absorber interactions wiherte the absorbing...molecular impurity is-a truly local probe of the minute details of a single local environment in a solid. l’he use of powerful spectroscopic methods as

  18. Comprehensive analysis of pyrimidine metabolism in 450 children with unspecific neurological symptoms using high-pressure liquid chromatography-electrospray ionization tandem mass spectrometry.

    PubMed

    Schmidt, C; Hofmann, U; Kohlmüller, D; Mürdter, T; Zanger, U M; Schwab, M; Hoffmann, G F

    2005-01-01

    To evaluate the significance of inborn metabolic disorders of the pyrimidine degradation pathway, 450 children with unspecific neurological symptoms were comprehensively studied; 200 healthy children were recruited as controls. Uracil and thymine as well as their degradation products in urine were determined with an improved method based on reversed-phase HPLC coupled with electrospray ionization tandem mass spectrometry and detection by multiple-reaction monitoring using stable-isotope-labelled reference compounds as internal standards. From the results of the control group we established age-related reference ranges of all pyrimidine degradation products. In the patient group, two children with dihydropyrimidine dehydrogenase (DPYD) deficiency were identified; one of these was homozygous for the exon 14-skipping mutation of the DPYD gene. In addition, two patients with high uracil, dihydrouracil and beta-ureidopropionate were found to have ornithine transcarbamylase deficiency. In the urine of 9 patients, beta-alanine was markedly elevated owing to treatment with vigabatrin, an irreversible inhibitor of GABA transaminase, which interferes with beta-alanine breakdown. Four patients had exclusively high levels of beta-aminoisobutyrate (beta-AIB) due to a low activity of the D-beta-AIB-pyruvate aminotransferase, probably without clinical significance. In conclusion, quantitative investigation of pyrimidine metabolites in children with unexplained neurological symptoms, particularly epileptic seizures with or without psychomotor retardation, can be recommended as a helpful tool for diagnosis in clinical practice. Sensitive methods and age-related reference ranges enable the detection of partial enzyme deficiencies.

  19. Supercritical fluid chromatography-photodiode array detection-electrospray ionization mass spectrometry as a framework for impurity fate mapping in the development and manufacture of drug substances.

    PubMed

    Pirrone, Gregory F; Mathew, Rose M; Makarov, Alexey A; Bernardoni, Frank; Klapars, Artis; Hartman, Robert; Limanto, John; Regalado, Erik L

    2018-03-30

    Impurity fate and purge studies are critical in order to establish an effective impurity control strategy for approval of the commercial filing application of new medicines. Reversed phase liquid chromatography-diode array-mass spectrometry (RPLC-DAD-MS) has traditionally been the preferred tool for impurity fate mapping. However, separation of some reaction mixtures by LC can be very problematic requiring combination LC-UV for area % analysis and a different LC-MS method for peak identification. In addition, some synthetic intermediates might be chemically susceptible to the aqueous conditions used in RPLC separations. In this study, the use of supercritical fluid chromatography-photodiode array-electrospray ionization mass spectrometry (SFC-PDA-ESIMS) for fate and purge of two specified impurities in the 1-uridine starting material from the synthesis of a bis-piv 2'keto-uridine, an intermediate in the synthesis of uprifosbuvir, a treatment under investigation for chronic hepatitis C infection. Readily available SFC instrumentation with a Chiralpak IC column (4.6 × 150 mm, 3 μm) and ethanol: carbon dioxide based mobile phase eluent enabled the separation of closely related components from complex reaction mixtures where RLPC failed to deliver optimal chromatographic performance. These results illustrate how SFC combined with PDA and ESI-MS detection can become a powerful tool for direct impurity fate mapping across multiple reaction steps. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Use of high-performance liquid chromatography with diode array detection coupled to electrospray-Qq-time-of-flight mass spectrometry for the direct characterization of the phenolic fraction in organic commercial juices.

    PubMed

    Rodríguez-Medina, I C; Segura-Carretero, A; Fernández-Gutiérrez, A

    2009-06-05

    We have developed a direct method for the qualitative analysis of polyphenols in commercial organic fruit juices. The juices were diluted with water (50/50), filtered and directly injected. The analysis of phenolic compounds was carried out by reversed-phase high-performance liquid chromatography (RP-HPLC) coupled to photodiode array detection (DAD) and electrospray ionisation-Qq-time-of-flight mass spectrometry (ESI-Qq-TOF-MS). A unique gradient program has been optimized for the separation of several phenolic classes and the analysis time was only 5 min. The fruit juice samples were successfully analysed in positive and negative ionisation modes. In positive mode the anthocyanins were identified whereas the vast majority of polyphenols were identified using the negative ionisation mode. The sensitivity, together with mass accuracy and true isotopic pattern of the Qq-TOF-MS, allowed the identification of the phenolic compounds. Moreover, the advantage of the proposed method is the combined search of MS and MS/MS spectra, which improves the identification of compounds considerably, reducing ambiguities and false positive hits. Therefore the total fragmentation of the compound ion leading to the aglycone ion or other fragments was corroborated by MS-MS. The method was successfully employed to characterize diverse phenolic families in commercially available organic juices from four different fruits and consequently could be used in the future for the quantification purposes to compare different content of polyphenols in juices.

  1. Flame Atmospheric Pressure Chemical Ionization Coupled with Negative Electrospray Ionization Mass Spectrometry for Ion Molecule Reactions

    NASA Astrophysics Data System (ADS)

    Cheng, Sy-Chyi; Bhat, Suhail Muzaffar; Shiea, Jentaie

    2017-07-01

    Flame atmospheric pressure chemical ionization (FAPCI) combined with negative electrospray ionization (ESI) mass spectrometry was developed to detect the ion/molecule reactions (IMRs) products between nitric acid (HNO3) and negatively charged amino acid, angiotensin I (AI) and angiotensin II (AII), and insulin ions. Nitrate and HNO3-nitrate ions were detected in the oxyacetylene flame, suggesting that a large quantity of nitric acid (HNO3) was produced in the flame. The HNO3 and negatively charged analyte ions produced by a negative ESI source were delivered into each arm of a Y-shaped stainless steel tube where they merged and reacted. The products were subsequently characterized with an ion trap mass analyzer attached to the exit of the Y-tube. HNO3 showed the strongest affinity to histidine and formed (Mhistidine-H+HNO3)- complex ions, whereas some amino acids did not react with HNO3 at all. Reactions between HNO3 and histidine residues in AI and AII resulted in the formation of dominant [MAI-H+(HNO3)]- and [MAII-H+(HNO3)]- ions. Results from analyses of AAs and insulin indicated that HNO3 could not only react with basic amino acid residues, but also with disulfide bonds to form [M-3H+(HNO3)n]3- complex ions. This approach is useful for obtaining information about the number of basic amino acid residues and disulfide bonds in peptides and proteins.

  2. Flame Atmospheric Pressure Chemical Ionization Coupled with Negative Electrospray Ionization Mass Spectrometry for Ion Molecule Reactions.

    PubMed

    Cheng, Sy-Chyi; Bhat, Suhail Muzaffar; Shiea, Jentaie

    2017-07-01

    Flame atmospheric pressure chemical ionization (FAPCI) combined with negative electrospray ionization (ESI) mass spectrometry was developed to detect the ion/molecule reactions (IMRs) products between nitric acid (HNO 3 ) and negatively charged amino acid, angiotensin I (AI) and angiotensin II (AII), and insulin ions. Nitrate and HNO 3 -nitrate ions were detected in the oxyacetylene flame, suggesting that a large quantity of nitric acid (HNO 3 ) was produced in the flame. The HNO 3 and negatively charged analyte ions produced by a negative ESI source were delivered into each arm of a Y-shaped stainless steel tube where they merged and reacted. The products were subsequently characterized with an ion trap mass analyzer attached to the exit of the Y-tube. HNO 3 showed the strongest affinity to histidine and formed (M histidine -H+HNO 3 ) - complex ions, whereas some amino acids did not react with HNO 3 at all. Reactions between HNO 3 and histidine residues in AI and AII resulted in the formation of dominant [M AI -H+(HNO 3 )] - and [M AII -H+(HNO 3 )] - ions. Results from analyses of AAs and insulin indicated that HNO 3 could not only react with basic amino acid residues, but also with disulfide bonds to form [M-3H+(HNO 3 ) n ] 3- complex ions. This approach is useful for obtaining information about the number of basic amino acid residues and disulfide bonds in peptides and proteins. Graphical Abstract ᅟ.

  3. Simultaneous measurement of proline and related compounds in oak leaves by high-performance ligand-exchange chromatography and electrospray ionization mass spectrometry for environmental stress studies.

    PubMed

    Oufir, Mouhssin; Schulz, Nadine; Sha Vallikhan, Patan Shaik; Wilhelm, Eva; Burg, Kornel; Hausman, Jean-Francois; Hoffmann, Lucien; Guignard, Cedric

    2009-02-13

    A mass spectrometer was coupled to high-performance ligand-exchange liquid chromatography (HPLEC) for simultaneous analysis of stress associated solutes such as proline, hydroxyproline, methylproline, glycine betaine and trigonelline extracted from leaves of drought stressed oaks and an internal standard namely N-acetylproline. Methanol/chloroform/water extracts were analyzed using an Aminex HPX-87C column and specifically quantified by the positive ion mode of an electrospray ionisation-mass spectrometry (ESI-MS) in single ion monitoring (SIM) mode. The recovery of N-acetyl proline added to oak leaf extracts ranged from 85.2 to 122.1% for an intra-day study. Standard calibration curves showed good linearity in the measured range from 0.3125 to 10micromolL(-1) with the lowest correlation coefficient of 0.99961 for trigonelline. The advantages of this alternative procedure, compared to previously published methods using fluorescence or amperometric detections, are the simultaneous and direct detection of osmoprotectants in a single chromatographic run, a minimal sample preparation, a good specificity and reduced limits of quantification, ranging from 0.1 to 0.6micromolL(-1). Fifty-six days of water deficit exposure resulted in increased foliar free proline levels (2.4-fold, P<0.001, 155micromolg(-1) FW) and glycine betaine contents (2.5-fold, P<0.05, 175micromolg(-1) FW) of drought stressed oak compared to control.

  4. Simultaneous determination of tetrahydropalmatine, protopine, and palmatine in rat plasma by LC-ESI-MS and its application to a pharmacokinetic study.

    PubMed

    Ma, Hongda; Wang, Yongjun; Guo, Tao; He, Zhonggui; Chang, Xinyu; Pu, Xiaohui

    2009-02-20

    A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method has been developed and validated for the simultaneous quantification of tetrahydropalmatine, protopine and palmatine in rat plasma using phenacetin as the internal standard (IS). Two hundred microliters plasma samples were extracted by dichloromethane under a strong basic condition. The analytes were separated by a C18 column and detected with a single quadrupole mass spectrometer. The used mobile phase was acetonitrile-water (40:60, v/v) containing 5mM ammonium acetate and 0.2% glacial acetic acid. Detection was carried out by positive electrospray ionization in selected ion reaction (SIR) mode at m/z 356.6 for tetrahydropalmatine, 354.6 for protopine, 352.6 for palmatine and 180.4 for the IS, respectively. The method was validated over the concentration range of 1.00-500ngmL(-1) and the lower limit of quantification (LLOQ) was 1.00ngmL(-1) for all three analytes. The intra- and inter-day precision values were less than 9% relative standard deviation (R.S.D.), and the relative error ranged from -7.4 to 4.8%. The extraction recoveries were on average 91.42% for tetrahydropalmatine, 84.75% for protopine, 57.26% for palmatine, and 83.18% for IS. The validated method was successfully applied to a pharmacokinetic study of tetrahydropalmatine, protopine and palmatine in rats after oral administration of Rhizoma Corydalis Decumbentis extract.

  5. Benzylic rearrangement stable isotope labeling for quantitation of guanidino and ureido compounds in thyroid tissues by liquid chromatography-electrospray ionization mass spectrometry.

    PubMed

    Fan, Ruo-Jing; Guan, Qing; Zhang, Fang; Leng, Jia-Peng; Sun, Tuan-Qi; Guo, Yin-Long

    2016-02-18

    Benzylic rearrangement stable isotope labeling (BRSIL) was explored to quantify the guanidino and ureido compounds (GCs and UCs). This method employed a common reagent, benzil, to label the guanidino and ureido groups through nucleophilic attacking then benzylic migrating. The use of BRSIL was investigated in the analysis of five GCs (creatine, l-arginine, homoarginine, 4-guanidinobutyric acid, and methylguanidine) and two UCs (urea and citrulline). The labeling was found simple and specific. The introduction of bi-phenyl group and the generation of nitrogen heterocyclic ring in the benzil-d0/d5 labeled GCs and UCs improved the retention behaviors in liquid chromatography (LC) and increased the sensitivity of electrospray ionization mass spectrometry (ESI MS) detection. The fragment ion pairs of m/z 182/187 and m/z 210/215 from the benzil-d0/d5 tags facilitated the discovery of potential GCs and UCs candidates residing in biological matrices. The use of BRSIL combined with LC-ESI MS was applied for simultaneously quantitation of GCs and UCs in thyroid tissues. It was demonstrated that nine GCs and UCs were detected, six of which were further quantified based on corresponding standards. It was concluded that five GCs and UCs (l-arginine, homoarginine, 4-guanidinobutyric acid, methylguanidine, and citrulline) were statistically significantly different (p < 0.05) between the para-carcinoma and carcinoma thyroid tissue samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Method of analyzing multiple sample simultaneously by detecting absorption and systems for use in such a method

    DOEpatents

    Yeung, Edward S.; Gong, Xiaoyi

    2004-09-07

    The present invention provides a method of analyzing multiple samples simultaneously by absorption detection. The method comprises: (i) providing a planar array of multiple containers, each of which contains a sample comprising at least one absorbing species, (ii) irradiating the planar array of multiple containers with a light source and (iii) detecting absorption of light with a detetion means that is in line with the light source at a distance of at leaat about 10 times a cross-sectional distance of a container in the planar array of multiple containers. The absorption of light by a sample indicates the presence of an absorbing species in it. The method can further comprise: (iv) measuring the amount of absorption of light detected in (iii) indicating the amount of the absorbing species in the sample. Also provided by the present invention is a system for use in the abov metho.The system comprises; (i) a light source comrnpising or consisting essentially of at leaat one wavelength of light, the absorption of which is to be detected, (ii) a planar array of multiple containers, and (iii) a detection means that is in line with the light source and is positioned in line with and parallel to the planar array of multiple contiainers at a distance of at least about 10 times a cross-sectional distance of a container.

  7. Analysis of heparin oligosaccharides by capillary electrophoresis-negative-ion electrospray ionization mass spectrometry.

    PubMed

    Lin, Lei; Liu, Xinyue; Zhang, Fuming; Chi, Lianli; Amster, I Jonathan; Leach, Franklyn E; Xia, Qiangwei; Linhardt, Robert J

    2017-01-01

    Most hyphenated analytical approaches that rely on liquid chromatography-MS require relatively long separation times, produce incomplete resolution of oligosaccharide mixtures, use eluents that are incompatible with electrospray ionization, or require oligosaccharide derivatization. Here we demonstrate the analysis of heparin oligosaccharides, including disaccharides, ultralow molecular weight heparin, and a low molecular weight heparin, using a novel electrokinetic pump-based CE-MS coupling eletrospray ion source. Reverse polarity CE separation and negative-mode electrospray ionization were optimized using a volatile methanolic ammonium acetate electrolyte and sheath fluid. The online CE hyphenated negative-ion electrospray ionization MS on an LTQ Orbitrap mass spectrometer was useful in disaccharide compositional analysis and bottom-up and top-down analysis of low molecular weight heparin. The application of this CE-MS method to ultralow molecular heparin suggests that a charge state distribution and the low level of sulfate group loss that is achieved make this method useful for online tandem MS analysis of heparins. Graphical abstract Most hyphenated analytical approaches that rely on liquid chromatography-MS require relatively long separation times, produce incomplete resolution of oligosaccharide mixtures, use eluents that are incompatible with electrospray ionization, or require oligosaccharide derivatization. Here we demonstrate the analysis of heparin oligosaccharides, including disaccharides, ultralow molecular weight heparin, and a low molecular weight heparin, using a novel electrokinetic pump-based CE-MS coupling eletrospray ion source. Reverse polarity CE separation and negative-mode electrospray ionization were optimized using a volatile methanolic ammonium acetate electrolyte and sheath fluid. The online CE hyphenated negative-ion electrospray ionization MS on an LTQ Orbitrap mass spectrometer was useful in disaccharide compositional analysis and bottom-up and top-down analysis of low molecular weight heparin. The application of this CE-MS method to ultralow molecular heparin suggests that a charge state distribution and the low level of sulfate group loss that is achieved make this method useful for online tandem MS analysis of heparins.

  8. Broad-Range Direct Detection and Identification of Fungi by Use of the PLEX-ID PCR-Electrospray Ionization Mass Spectrometry (ESI-MS) System

    PubMed Central

    Simner, Patricia J.; Uhl, James R.; Hall, Leslie; Weber, Michelle M.; Walchak, Robert C.; Buckwalter, Seanne

    2013-01-01

    The PLEX-ID system is a novel technology that couples PCR amplification and electrospray ionization-mass spectrometry to identify pathogens directly in clinical specimens. The analytical performance of the PLEX-ID Broad Fungal assay was compared with that of traditional culture identification by using 91 characterized fungal culture isolates (64 manufacturer-claimed and 27 nonclaimed organisms) and directly by using 395 respiratory specimens. Discordant results were resolved by D2 large-subunit ribosomal DNA fungal sequencing. Environmental studies were performed to monitor for potential contamination. The PLEX-ID Broad Fungal assay correctly identified 95.6% (87/91) and 81.3% (74/91) of the culture isolates to the genus and species levels, respectively. Of the manufacturer-claimed organisms, 100% (64/64) and 92.2% (59/64) were correctly identified to the genus and species levels, respectively. Direct analysis of respiratory specimens resulted in 67.6% (267/395) and 66.6% (263/395) agreement with culture results to the genus and species levels, respectively, with 16.2% (64/395) of the results discordant with culture and 16.2% (64/395) not detected by the system. The majority (>95%) of the isolates not detected directly by the PLEX-ID system ultimately grew in low quantities in culture (≤20 colonies). In 20.3% (35/172) of the respiratory specimens where no growth was observed in culture, the PLEX-ID system identified a fungus, suggesting a potential increase in sensitivity over culture in some instances. The PLEX-ID system provides a rapid method for the detection of a broad array of fungi directly in respiratory specimens and has the potential of impacting turnaround times and patient care by reducing the need to wait for the growth of an organism in culture. PMID:23515540

  9. Lipidomics as an important key for the identification of beer-spoilage bacteria.

    PubMed

    Řezanka, T; Matoulková, D; Benada, O; Sigler, K

    2015-06-01

    Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) was used for characterizing intact plasmalogen phospholipid molecules in beer-spoilage bacteria. Identification of intact plasmalogens was carried out using collision-induced dissociation and the presence of suitable marker molecular species, both qualitative and quantitative, was determined in samples containing the anaerobic bacteria Megasphaera and Pectinatus. Using selected ion monitoring (SIM), this method had a limit of detection at 1 pg for the standard, i.e. 1-(1Z-octadecenyl)-2-oleoyl-sn-glycero-3-phosphoethanolamine and be linear in the range of four orders of magnitude from 2 pg to 20 ng. This technique was applied to intact plasmalogen extracts from the samples of contaminated and uncontaminated beer without derivatization and resulted in the identification of contamination of beer by Megasphaera and Pectinatus bacteria. The limit of detection was about 830 cells of anaerobic bacteria, i.e. bacteria containing natural cyclopropane plasmalogenes (c-p-19:0/15:0), which is the majority plasmalogen located in both Megasphaera and Pectinatus. The SIM ESI-MS method has been shown to be useful for the analysis of low concentration of plasmalogens in all biological samples, which were contaminated with anaerobic bacteria, e.g. juice, not only in beer. Significance and impact of the study: Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) using collision-induced dissociation was used to characterize intact plasmalogen phospholipid molecules in beer-spoilage anaerobic bacteria Megasphaera and Pectinatus. Using selected ion monitoring (SIM), this method has a detection limit of 1 pg for the standard 1-(1Z-octadecenyl)-2-oleoyl-sn-glycero-3-phosphoethanolamine and is linear within four orders of magnitude (2 pg to 20 ng). The limit of detection was about 830 cells of bacteria containing natural cyclopropane plasmalogen (c-p-19:0/15:0). SIM ESI-MS method is useful for analyzing low concentrations of plasmalogens in biological samples contaminated with anaerobic bacteria, e.g. beer or juice. © 2015 The Society for Applied Microbiology.

  10. Attachment of chloride anion to sugars: mechanistic investigation and discovery of a new dopant for efficient sugar ionization/detection in mass spectrometers.

    PubMed

    Boutegrabet, Lemia; Kanawati, Basem; Gebefügi, Istvan; Peyron, Dominique; Cayot, Philippe; Gougeon, Régis D; Schmitt-Kopplin, Philippe

    2012-10-08

    A new method for efficient ionization of sugars in the negative-ion mode of electrospray mass spectrometry is presented. Instead of using strongly hydrophobic dopants such as dichloromethane or chloroform, efficient ionization of sugars has been achieved by using aqueous HCl solution for the first time. This methodology makes it possible to use hydrophilic dopants, which are more appropriate for chromatographic separation techniques with efficient sugar ionization and detection in mass spectrometry. The interaction between chloride anions and monosaccharides (glucose and galactose) was studied by DFT in the gas phase and by implementing the polarizable continuum model (PCM) for calculations in solution at the high B3LYP/6-31+G(d,p)//B3LYP/6-311+G(2d,p) level of theory. In all optimized geometries of identified [M+Cl](-) anions, a non-covalent interaction exists. Differences were revealed between monodentate and bidentate complex anions, with the latter having noticeably higher binding energies. The calculated affinity of glucose and galactose toward the chloride anion in the gas phase and their chloride anion binding energies in solution are in excellent agreement with glucose and galactose [M+Cl](-) experimental intensity profiles that are represented as a function of the chloride ion concentration. Density functional calculations of gas-phase affinities toward chloride anion were also performed for the studied disaccharides sucrose and gentiobiose. All calculations are in excellent agreement with the experimental data. An example is introduced wherein HCl was used to effectively ionize sugars and form chlorinated adduct anions to detect sugars and glycosylated metabolites (anthocyanins) in real biological systems (Vitis vinifera grape extracts and wines), whereas they would not have been easily detectable under standard infusion electrospray mass spectrometry conditions as deprotonated species. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Development of Coatings for Radar Absorbing Materials at X-band

    NASA Astrophysics Data System (ADS)

    Kumar, Abhishek; Singh, Samarjit

    2018-03-01

    The present review gives a brief account on some of the technical features of radar absorbing materials (RAMs). The paper has been presented with a concentrated approach towards the material aspects for achieving enhanced radar absorption characteristics for its application as a promising candidate in stealth technology and electromagnetic interference (EMI) minimization problems. The effect of metal particles doping/dispersion in the ferrites and dielectrics has been discussed for obtaining tunable radar absorbing characteristics. A short theoretical overview on the development of absorber materials, implementation of genetic algorithm (GA) in multi-layering and frequency selective surfaces (FSSs) based multi-layer has also been presented for the development of radar absorbing coatings for achieving better absorption augmented with broadband features in order to counter the radar detection systems.

  12. Electrosprayed Cerium Oxide Nanoparticles

    NASA Astrophysics Data System (ADS)

    Azar, Pedram Bagherzadeh; Tavanai, Hossein; Allafchian, Ali Reza

    2018-04-01

    Cerium oxide nanoparticles were fabricated via the calcination of electrosprayed polyvinyl alcohol (PVA)/cerium nitrate nanoparticles. The effect of material variables of PVA/cerium nitrate electrospraying solution, i.e. viscosity, surface tension and electrical conductivity, as well as important process variables like voltage, nozzle-collector distance and feed rate on cerium oxide nanoparticle size, are investigated. Scanning electron microscopy and Fourier-transform infrared (FTIR) spectroscopy analysis have also been carried out. The results showed that electrospraying of PVA/cerium nitrate (25% w/v) was only possible with PVA concentrations in the range of 5-8% w/v. With other conditions constant, decreasing PVA concentration, decreasing feed rate, increasing nozzle-collector distance and increasing voltage decreased the size of the final cerium oxide nanoparticles. The gross average size of all cerium oxide nanoparticles obtained in this work was about 80 nm. FTIR analysis proved the formation of cerium oxide after the calcination process.

  13. Jean-Antoine Nollet: The father of experimental electrospray.

    PubMed

    Dumont, Quentin; Cole, Richard B

    2014-01-01

    The development of electrospray ionization mass spectrometry (ESI-MS) was a 20th century occurrence that underwent rapid acceleration especially in the 1990's. However, long prior to its coupling with mass spectrometry, the electrification of liquids had been studied in a variety of contexts. Although initial reports describing cone formation upon electrification of water drops came out of England, the first true experiments investigating the electrospray phenomenon were performed in the middle of the 18th century by Abbé Jean-Antoine Nollet. The current report, associated with the French Regional Issue of Mass Spectrometry Reviews, examines the contributions of Abbé Nollet to the earliest understanding of the electrospray phenomenon. A description of his accomplishments is placed in the context of the societal and scientific developments of the "Age of Enlightenment" out of which Jean-Antoine Nollet arose. © 2013 Wiley Periodicals, Inc.

  14. Desorption electrospray ionization mass spectrometry for trace analysis of agrochemicals in food.

    PubMed

    García-Reyes, Juan F; Jackson, Ayanna U; Molina-Díaz, Antonio; Cooks, R Graham

    2009-01-15

    Desorption electrospray ionization (DESI) is applied to the rapid, in situ, direct qualitative and quantitative (ultra)trace analysis of agrochemicals in foodstuffs. To evaluate the potential of DESI mass spectrometry (MS) in toxic residue testing in food, 16 representative multiclass agricultural chemicals (pesticides, insecticides, herbicides, and fungicides) were selected (namely, ametryn, amitraz, azoxystrobin, bitertanol, buprofezin, imazalil, imazalil metabolite, isofenphos-methyl, malathion, nitenpyram, prochloraz, spinosad, terbuthylazine, thiabendazole, and thiacloprid). The DESI-MS experiments were performed using 3 microL of solution spotted onto conventional smooth poly(tetrafluoroethylene) (PTFE) surfaces, with examination by MS and tandem mass spectrometry (MS/MS) using an ion trap mass spectrometer. Optimization of the spray solvent led to the use of acetonitrile/water (80:20) (v/v), with 1% formic acid. Most of the compounds tested showed remarkable sensitivity in the positive ion mode, approaching that attainable with conventional direct infusion electrospray mass spectrometry. To evaluate the potential of the proposed approach in real samples, different experiments were performed including the direct DESI-MS/MS analysis of fruit peels and also of fruit/vegetable extracts. The results proved that DESI allows the detection and confirmation of traces of agrochemicals in actual market-purchased samples. In addition, MS/MS confirmation of selected pesticides in spiked vegetable extracts was obtained at absolute levels as low as 1 pg for ametryn. Quantitation of imazalil residues was also undertaken using an isotopically labeled standard. The data obtained were in agreement with those from the liquid chromatography mass spectrometry (LC-MS) reference method, with relative standard deviation (RSD) values consistently below 15%. The results obtained demonstrate the sensitivity of DESI as they meet the stringent European Union pesticide regulation requirements (maximum residue levels) for a large percentage of the studied compounds.

  15. Determination of phosphatidylethanolamine molecular species in various food matrices by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS2).

    PubMed

    Zhou, Li; Zhao, Minjie; Ennahar, Saïd; Bindler, Françoise; Marchioni, Eric

    2012-04-01

    A liquid chromatographic-electrospray ionization-tandem mass spectrometric (LC-ESI-MS(2)) method has been developed for determination of the molecular species of phosphatidylethanolamine (PE) in four food matrices (soy, egg yolk, ox liver, and krill oil). The extraction and purification method consisted of a pressurized liquid extraction procedure for total lipid (TL) extraction, purification of phospholipids (PLs) by adsorption on a silica gel column, and separation of PL classes by semi-preparative normal-phase HPLC. Separation and identification of PE molecular species were performed by reversed-phase HPLC coupled with electrospray ionization tandem mass spectrometry (ESI-MS(2)). Methanol containing 5 mmol L(-1) ammonium formate was used as the mobile phase. A variety of PE molecular species were detected in the four food matrices. (C16:0-C18:2)PE, (C18:2-C18:2)PE, and (C16:0-C18:1)PE were the major PE molecular species in soy. Egg yolk PE contained (C16:0-C18:1)PE, (C18:0-C18:1)PE, (C18:0-C18:2)PE, and (C16:0-C18:2)PE as the major molecular species. Ox liver PE was rich in the species (C18:0-C18:1)PE, (C18:0-C20:4)PE, and (C18:0-C18:2)PE. Finally, krill oil which was particularly rich in (C16:0(alkyl)-C22:6(acyl))plasmanylethanolamine (PakE), (C16:0-C22:6)PE, and (C16:0-C20:5)PE, seemed to be an interesting potential source for supplementation of food with eicosapentaenoic acid and docosahexaenoic acid.

  16. Ammonium Ion Binding to DNA G-Quadruplexes: Do Electrospray Mass Spectra Faithfully Reflect the Solution-Phase Species?

    NASA Astrophysics Data System (ADS)

    Balthasart, Françoise; Plavec, Janez; Gabelica, Valérie

    2013-01-01

    G-quadruplex nucleic acids can bind ammonium ions in solution, and these complexes can be detected by electrospray mass spectrometry (ESI-MS). However, because ammonium ions are volatile, the extent to which ESI-MS quantitatively could provide an accurate reflection of such solution-phase equilibria is unclear. Here we studied five G-quadruplexes having known solution-phase structure and ammonium ion binding constants: the bimolecular G-quadruplexes (dG4T4G4)2, (dG4T3G4)2, and (dG3T4G4)2, and the intramolecular G-quadruplexes dG4(T4G4)3 and dG2T2G2TGTG2T2G2 (thrombin binding aptamer). We found that not all mass spectrometers are equally suited to reflect the solution phase species. Ion activation can occur in the electrospray source, or in a high-pressure traveling wave ion mobility cell. When the softest instrumental conditions are used, ammonium ions bound between G-quartets, but also additional ammonium ions bound at specific sites outside the external G-quartets, can be observed. However, even specifically bound ammonium ions are in some instances too labile to be fully retained in the gas phase structures, and although the ammonium ion distribution observed by ESI-MS shows biases at specific stoichiometries, the relative abundances in solution are not always faithfully reflected. Ion mobility spectrometry results show that all inter-quartet ammonium ions are necessary to preserve the G-quadruplex fold in the gas phase. Ion mobility experiments, therefore, help assign the number of inner ammonium ions in the solution phase structure.[Figure not available: see fulltext.

  17. Ultrahigh-performance liquid chromatography/electrospray ionization linear ion trap Orbitrap mass spectrometry of antioxidants (amines and phenols) applied in lubricant engineering.

    PubMed

    Kassler, Alexander; Pittenauer, Ernst; Doerr, Nicole; Allmaier, Guenter

    2014-01-15

    For the qualification and quantification of antioxidants (aromatic amines and sterically hindered phenols), most of them applied as lubricant additives, two ultrahigh-performance liquid chromatography (UHPLC) electrospray ionization mass spectrometric methods applying the positive and negative ion mode have been developed for lubricant design and engineering thus allowing e.g. the study of the degradation of lubricants. Based on the different chemical properties of the two groups of antioxidants, two methods offering a fast separation (10 min) without prior derivatization were developed. In order to reach these requirements, UHPLC was coupled with an LTQ Orbitrap hybrid tandem mass spectrometer with positive and negative ion electrospray ionization for simultaneous detection of spectra from UHPLC-high-resolution (HR)-MS (full scan mode) and UHPLC-low-resolution linear ion trap MS(2) (LITMS(2)), which we term UHPLC/HRMS-LITMS(2). All 20 analytes investigated could be qualified by an UHPLC/HRMS-LITMS(2) approach consisting of simultaneous UHPLC/HRMS (elemental composition) and UHPLC/LITMS(2) (diagnostic product ions) according to EC guidelines. Quantification was based on an UHPLC/LITMS(2) approach due to increased sensitivity and selectivity compared to UHPLC/HRMS. Absolute quantification was only feasible for seven analytes with well-specified purity of references whereas relative quantification was obtainable for another nine antioxidants. All of them showed good standard deviation and repeatability. The combined methods allow qualitative and quantitative determination of a wide variety of different antioxidants including aminic/phenolic compounds applied in lubricant engineering. These data show that the developed methods will be versatile tools for further research on identification and characterization of the thermo-oxidative degradation products of antioxidants in lubricants. Copyright © 2013 John Wiley & Sons, Ltd.

  18. Signal enhancement for gradient reverse-phase high-performance liquid chromatography-electrospray ionization mass spectrometry analysis with trifluoroacetic and other strong acid modifiers by postcolumn addition of propionic acid and isopropanol.

    PubMed

    Kuhlmann, F E; Apffel, A; Fischer, S M; Goldberg, G; Goodley, P C

    1995-12-01

    Trifluoroacetic acid (TFA) and other volatile strong acids, used as modifiers in reverse-phase high-performance liquid chromatography, cause signal suppression for basic compounds when analyzed by electrospray ionization mass spectrometry (ESI-MS). Evidence is presented that signal suppression is caused by strong ion pairing between the TFA anion and the protonated sample cation of basic sample molecules. The ion-pairing process "masks" the protonated sample cations from the ESI-MS electric fields by rendering them "neutral. " Weakly basic molecules are not suppressed by this process. The TFA signal suppression effect is independent from the well-known spray problem that electrospray has with highly aqueous solutions that contain TFA. This previously reported spray problem is caused by the high conductivity and surface tension of aqueous TFA solutions. A practical method to enhance the signal for most basic analytes in the presence of signal-suppressing volatile strong acids has been developed. The method employs postcolumn addition of a solution of 75% propionic acid and 25% isopropanol in a ratio 1:2 to the column flow. Signal enhancement is typically 10-50 times for peptides and other small basic molecules. Thus, peptide maps that use ESI-MS for detection can be performed at lower levels, with conventional columns, without the need to use capillary chromatography or reduced mass spectral resolution to achieve satisfactory sensitivity. The method may be used with similar results for heptafluorobutyric acid and hydrochloric acid. A mechanism for TFA signal suppression and signal enhancement by the foregoing method, is proposed.

  19. Expression of cholesteryl glucoside by heat shock in human fibroblasts

    PubMed Central

    Kunimoto, Shohko; Kobayashi, Tetsuyuki; Kobayashi, Susumu; Murakami-Murofushi, Kimiko

    2000-01-01

    ABSTRACT We investigated the heat-induced alteration of glycolipids in human cultured cells, TIG-3 fibroblasts, to show the expression of steryl glucoside by heat shock. A glycolipid band was detected on a thin-layer chromatography plate in lipid extracts from TIG-3 cells exposed to high temperature (42°C) for 15 and 30 minutes, while it was hardly detectable without heat shock. Both cholesterol and glucose were almost exclusively detected by gas liquid chromatography as degradation products of the lipid. The structure of the lipid molecule was elucidated by electrospray mass spectrometry to be a cholesteryl glucoside. This is the first report to show the occurrence of a steryl glucoside in mammalian cells, and this substance is considered to have a significant role in heat shock responses in mammalian cells. PMID:10701833

  20. Note: Sensitive fluorescence detection through minimizing the scattering light by anti-reflective nanostructured materials

    NASA Astrophysics Data System (ADS)

    Xu, Supeng; Yin, Yanning; Gu, Ruoxi; Xia, Meng; Xu, Liang; Chen, Li; Xia, Yong; Yin, Jianping

    2018-04-01

    We demonstrate a new approach with fabrication of anti-reflective coating to substantially reduce the scattering light in an ultra-high vacuum during laser induced fluorescence (LIF) detection. To do so, the surface of the vacuum chamber in the detection region was blackened and coated with the special solar heat absorbing nanomaterials. We demonstrate that more than 97.5% of the stray light in the chamber spanning from near infrared to ultraviolet can be absorbed which effectively improves the signal to noise (S/N) ratio. With this technique, the LIF signal from the cold magnesium monofluoride molecules has been observed with an S/N ratio of ˜4 times better than without that.

  1. Formation of nitrogen- and sulfur-containing light-absorbing compounds accelerated by evaporation of water from secondary organic aerosols

    NASA Astrophysics Data System (ADS)

    Nguyen, Tran B.; Lee, Paula B.; Updyke, Katelyn M.; Bones, David L.; Laskin, Julia; Laskin, Alexander; Nizkorodov, Sergey A.

    2012-01-01

    Aqueous extracts of secondary organic aerosols (SOA) generated from the ozonolysis of d-limonene were subjected to dissolution, evaporation, and re-dissolution in the presence and absence of ammonium sulfate (AS). Evaporation with AS at pH 4-9 produced chromophores that were stable with respect to hydrolysis and had a distinctive absorption band at 500 nm. Evaporation accelerated the rate of chromophore formation by at least three orders of magnitude compared to the reaction in aqueous solution, which produced similar compounds. Absorption spectroscopy and high-resolution nanospray desorption electrospray ionization (nano-DESI) mass spectrometry experiments suggested that the molar fraction of the chromophores was small (<2%), and that they contained nitrogen atoms. Although the colored products represented only a small fraction of SOA, their large extinction coefficients (>105 L mol-1 cm-1 at 500 nm) increased the effective mass absorption coefficient of the residual organics in excess of 103 cm2 g-1 - a dramatic effect on the optical properties from minor constituents. Evaporation of SOA extracts in the absence of AS resulted in the production of colored compounds only when the SOA extract was acidified to pH ˜ 2 with sulfuric acid. These chromophores were produced by acid-catalyzed aldol condensation, followed by a conversion into organosulfates. The presence of organosulfates was confirmed by high resolution mass spectrometry experiments. Results of this study suggest that evaporation of cloud or fog droplets containing dissolved organics leads to significant modification of the molecular composition and serves as a potentially important source of light-absorbing compounds.

  2. Comparative study on intestinal metabolism and absorption in vivo of ginsenosides in sulphur-fumigated and non-fumigated ginseng by ultra performance liquid chromatography quadruple time-of-flight mass spectrometry based chemical profiling approach.

    PubMed

    Zhu, He; Shen, Hong; Xu, Jun; Xu, Jin-Di; Zhu, Ling-Ying; Wu, Jie; Chen, Hu-Biao; Li, Song-Lin

    2015-04-01

    Our previous study indicated that sulphur-fumigation of ginseng in post-harvest handling processes could induce chemical transformation of ginsenosides to generate multiple ginsenoside sulphur derivatives. In this study, the influence of sulphur-fumigation on intestinal metabolism and absorption in vivo of ginsenosides in ginseng was sequentially studied. The intestinal metabolic and absorbed profiles of ginsenosides in rats after intra-gastric (i.g.) administration of sulphur-fumigated ginseng (SFG) and non-fumigated ginseng (NFG) were comparatively characterized by a newly established ultra performance liquid chromatography quadruple time-of-flight mass spectrometry (UPLC-QTOF-MS/MS) with electrospray ionization negative (ESI-) mode. A novel strategy based on the characteristic product ions and fragmentation pathways of different types of aglycones (saponin skeletons) and glycosyl moieties was proposed and successfully applied to rapid structural identification of ginsenoside sulphur derivatives and relevant metabolites. In total, 18 ginsenoside sulphur derivatives and 26 ginsenoside sulphur derivative metabolites in the faeces together with six ginsenoside sulphur derivatives in the plasma were identified in the SFG-administrated group but not in the NFG-administrated group. The results clearly demonstrated that the intestinal metabolic and absorbed profiles of ginsenosides in sulphur-fumigated and non-fumigated ginseng were quite different, which inspired that sulphur-fumigation of ginseng should not be recommended before the bioactivity and toxicity of the ginsenoside sulphur derivatives were systematically evaluated. Copyright © 2014 John Wiley & Sons, Ltd.

  3. Separation of a chemically modified DNA oligomer bound by the carcinogen 2-Amino-1-methy-6-phenylimidazo [4,5-{beta}]pyridine using capillary gel electrophoresis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, T.N.

    1994-05-06

    We have optimized the reaction conditions under which unactivated metabolite of the food borne carcinogen 2-amino-1-methyl-6-phenylimidazo [4,5-{beta}]pyridine (PhIP) is covalently bound to the oligodeoxynucleotide d(CCTACGCATCC). Capillary electrophoresis (CE) was used to separate and characterize this DNA oligomer bound by PhIP. We observed 2 major and several minor PhIP adduct species. The 2 major adducts had different absorbance maxima; the major adduct eluates with faster and slower mobilities had absorbance maxima of 360 and 340 nm, respectively. One of the two major PhIP adduct species was resolvable but the peak was broad. Using detection at 260 nm, the other major PhIPmore » adduct with fastest electrophoretic mobility was not resolvable, but coelute with the huge broad unmodified DNA oligomer peak. However, at higher wavelengths (>320 nm) where DNA does not absorb, electropherograms generated by detection at these higher wavelengths showed very heterogeneous binding by PhIP to the DNA oligomer with no interfering absorbance by the DNA.« less

  4. Study of noninvasive detection of latent fingerprints using UV laser

    NASA Astrophysics Data System (ADS)

    Li, Hong-xia; Cao, Jing; Niu, Jie-qing; Huang, Yun-gang; Mao, Lin-jie; Chen, Jing-rong

    2011-06-01

    Latent fingerprints present a considerable challenge in forensics, and noninvasive procedure that captures a digital image of the latent fingerprints is significant in the field of criminal investigation. The capability of photography technologies using 266nm UV Nd:YAG solid state laser as excitation light source to provide detailed images of unprocessed latent fingerprints is demonstrated. Unprocessed latent fingerprints were developed on various non-absorbent and absorbing substrates. According to the special absorption, reflection, scattering and fluorescence characterization of the various residues in fingerprints (fatty acid ester, protein, and carbosylic acid salts etc) to the UV light to weaken or eliminate the background disturbance and increase the brightness contrast of fingerprints with the background, and using 266nm UV laser as excitation light source, fresh and old latent fingerprints on the surface of four types of non-absorbent objects as magazine cover, glass, back of cellphone, wood desktop paintwork and two types of absorbing objects as manila envelope, notebook paper were noninvasive detected and appeared through reflection photography and fluorescence photography technologies, and the results meet the fingerprint identification requirements in forensic science.

  5. Intracavity widely-tunable quantum cascade laser spectrometer.

    PubMed

    Brownsword, Richard A; Weidmann, Damien

    2013-01-28

    A grating-tuned extended-cavity quantum cascade laser (EC-QCL) operating around 7.6 µm was assembled to provide a tuning range of ~80 cm⁻¹ with output power of up to 30 mW. The EC-QCL output power was shown to be sensitive to the presence of a broadband absorbing gas mixture contained in a 2-cm cell introduced inside the extended laser cavity. In this arrangement, enhanced absorption relative to single path linear absorption was observed. To describe observations, in the QCL rate-equation model was included the effect of intracavity absorption. The model qualitatively reproduced the absorption behavior observed. In addition, it allowed quantitative measurements of mixing ratio of dimethyl carbonate, which was used as a test broadband absorber. A number of alternative data acquisition and reduction methods were identified. As the intracavity absorber modifies the laser threshold current, phase-sensitive detection of the laser threshold current was found to be the most attractive way to determine the mixing ratio of the absorber. The dimethyl carbonate detection limit was estimated to be 1.4 ppmv for 10 second integration. Limitations and possible ways of improvements were also identified.

  6. Microwave Kinetic Inductance Detector with Selective Polarization Coupling

    NASA Technical Reports Server (NTRS)

    Wollack, Edward; U-yen, Kongpop; Stevenson, Thomas; Brown, Ari; Moseley, Samuel; Hsieh, Wen-Ting

    2013-01-01

    A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.

  7. Discovery of OH Absorption from a Galaxy at z ∼ 0.05: Implications for Large Surveys with SKA Pathfinders

    NASA Astrophysics Data System (ADS)

    Gupta, N.; Momjian, E.; Srianand, R.; Petitjean, P.; Noterdaeme, P.; Gyanchandani, D.; Sharma, R.; Kulkarni, S.

    2018-06-01

    We present the first detection of OH absorption in diffuse gas at z > 0, along with another eight stringent limits on OH column densities for cold atomic gas in galaxies at 0 < z < 0.4. The absorbing gas detected toward Q0248+430 (z q = 1.313) originates from a tidal tail emanating from a highly star-forming galaxy G0248+430 (z g = 0.0519) at an impact parameter of 15 kpc. The measured column density is N(OH) = (6.3 ± 0.8) × 1013 ≤ft(\\tfrac{{T}ex}}{3.5}\\right)≤ft(\\tfrac{1.0}{{f}cOH}}\\right) cm‑2, where {f}cOH} and T ex are the covering factor and the excitation temperature of the absorbing gas, respectively. In our Galaxy, the column densities of OH in diffuse clouds are of the order of N(OH) ∼ 1013–14 cm‑2. From the incidence (number per unit redshift; n 21) of H I 21 cm absorbers at 0.5 < z < 1 and assuming no redshift evolution, we estimate the incidence of OH absorbers (with log N(OH) > 13.6) to be n OH = {0.008}-0.008+0.018 at z ∼ 0.1. Based on this we expect to detect {10}-10+20 such OH absorbers from the MeerKAT Absorption Line Survey (MALS). Using H I 21 cm and OH 1667 MHz absorption lines detected toward Q0248+430, we estimate (ΔF/F) = (5.2 ± 4.5) × 10‑6, where F\\equiv {g}p{({α }2/μ )}1.57, α is the fine structure constant, μ is the electron–proton mass ratio, and g p is the proton gyromagnetic ratio. This corresponds to Δα/α(z = 0.0519) = (1.7 ± 1.4) × 10‑6, which is among the stringent constraints on the fractional variation of α.

  8. Probing the Metal Enrichment of the Intergalactic Medium at z = 5–6 Using the Hubble Space Telescope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cai, Zheng; Fan, Xiaohui; Dave, Romeel

    We test the galactic outflow model by probing associated galaxies of four strong intergalactic C iv absorbers at z = 5–6 using the Hubble Space Telescope ( HST ) Advanced Camera for Surveys (ACS) ramp narrowband filters. The four strong C iv absorbers reside at z = 5.74, 5.52, 4.95, and 4.87, with column densities ranging from N {sub Civ} = 10{sup 13.8} to 10{sup 14.8} cm{sup −2}. At z = 5.74, we detect an i-dropout Ly α emitter (LAE) candidate with a projected impact parameter of 42 physical kpc from the C iv absorber. This LAE candidate has amore » Ly α -based star formation rate (SFR{sub Lyα} ) of 2 M {sub ⊙} yr{sup −1} and a UV-based SFR of 4 M {sub ⊙} yr{sup −1}. Although we cannot completely rule out that this i-dropout emitter may be an [O ii] interloper, its measured properties are consistent with the C iv powered galaxy at z = 5.74. For C iv absorbers at z = 4.95 and z = 4.87, although we detect two LAE candidates with impact parameters of 160 and 200 kpc, such distances are larger than that predicted from the simulations. Therefore, we treat them as nondetections. For the system at z = 5.52, we do not detect LAE candidates, placing a 3 σ upper limit of SFR{sub Lyα} ≈ 1.5 M {sub ⊙} yr{sup −1}. In summary, in these four cases, we only detect one plausible C iv source at z = 5.74. Combining the modest SFR of the one detection and the three nondetections, our HST observations strongly support that smaller galaxies (SFR{sub Lyα} ≲ 2 M {sub ⊙} yr{sup −1}) are main sources of intergalactic C iv absorbers, and such small galaxies play a major role in the metal enrichment of the intergalactic medium at z ≳ 5.« less

  9. Study on initiative vibration absorbing technology of optics in strong disturbed environment

    NASA Astrophysics Data System (ADS)

    Jia, Si-nan; Xiong, Mu-di; Zou, Xiao-jie

    2007-12-01

    Strong disturbed environment is apt to cause irregular vibration, which seriously affects optical collimation. To improve the performance of laser beam, three-point dynamic vibration absorbing method is proposed, and laser beam initiative vibration absorbing system is designed. The maladjustment signal is detected by position sensitive device (PSD), three groups of PZT are driven to adjust optical element in real-time, so the performance of output-beam is improved. The coupling model of the system is presented. Multivariable adaptive closed-loop decoupling arithmetic is used to design three-input-three-output decoupling controller, so that high precision dynamic adjusting is realized. Experiments indicate that the system has good shock absorbing efficiency.

  10. Two possible improvements for mass spectrometry analysis of intact biomolecules.

    PubMed

    Raznikov, Valeriy V; Zelenov, Vladislav V; Aparina, Elena V; Pikhtelev, Alexander R; Sulimenkov, Ilia V; Raznikova, Marina O

    2017-08-01

    The goals of our study were to investigate abilities of two approaches to eliminate possible errors in electrospray mass spectrometry measurements of biomolecules. Passing of a relatively dense supersonic gas jet through ionization region followed by its hitting the spray of the analyzed solution in low vacuum may be effective to keep an initial biomolecule structure in solution. Provided that retention of charge carriers for some sites in the biomolecule cannot be changed noticeably in electrospray ion source, decomposition and separation of charge-state distributions of electrosprayed ions may give additional information about native structure of biomolecules in solution.

  11. Plume collimation for laser ablation electrospray ionization mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vertes, Akos; Stolee, Jessica A.

    2016-06-07

    In various embodiments, a device may generally comprise a capillary having a first end and a second end; a laser to emit energy at a sample in the capillary to ablate the sample and generate an ablation plume in the capillary; an electrospray apparatus to generate an electrospray plume to intercept the ablation plume to produce ions; and a mass spectrometer having an ion transfer inlet to capture the ions. The ablation plume may comprise a collimated ablation plume. The device may comprise a flow cytometer. Methods of making and using the same are also described.

  12. Method and apparatus for multispray emitter for mass spectrometry

    DOEpatents

    Smith, Richard D.; Tang, Keqi; Lin, Yuehe

    2004-12-14

    A method and apparatus that utilizes two or more emitters simultaneously to form an electrospray of a sample that is then directed into a mass spectrometer, thereby increasing the total ion current introduced into an electrospray ionization mass spectrometer, given a liquid flow rate of a sample. The method and apparatus are most conveniently constructed as an array of spray emitters fabricated on a single chip, however, the present invention encompasses any apparatus wherein two or more emitters are simultaneously utilized to form an electrospray of a sample that is then directed into a mass spectrometer.

  13. Formation of metal-ion adducts and evidence for surface-catalyzed ionization in electrospray analysis of pharmaceuticals and pesticides

    USGS Publications Warehouse

    Thurman, E.M.; Ferrer, I.

    2002-01-01

    The formation of metal ion adducts in liquid chromatography/mass spectrometry positive-ion electrospray analysis of pharmaceuticals and pesticides was investigated. The evidence of surface-catalyzed ionization in the electrospray analysis was also studied. Both positive and negative ion mass spectrometry were used for the analysis of the products. It was found that the sodium adducts formed in the analysis included single, double, and triple sodium adducts. Adduction was found to occur by attachment of the metal ion to carboxyl, carbonyl and aromatic pi electrons of the molecule.

  14. Plume collimation for laser ablation electrospray ionization mass spectrometry

    DOEpatents

    Vertes, Akos; Stolee, Jessica A.

    2014-09-09

    In various embodiments, a device may generally comprise a capillary having a first end and a second end; a laser to emit energy at a sample in the capillary to ablate the sample and generate an ablation plume in the capillary; an electrospray apparatus to generate an electrospray plume to intercept the ablation plume to produce ions; and a mass spectrometer having an ion transfer inlet to capture the ions. The ablation plume may comprise a collimated ablation plume. The device may comprise a flow cytometer. Methods of making and using the same are also described.

  15. Development and characterization of electrosprayed Alyssum homolocarpum seed gum nanoparticles for encapsulation of d-limonene.

    PubMed

    Khoshakhlagh, Khadije; Koocheki, Arash; Mohebbi, Mohebbat; Allafchian, Alireza

    2017-03-15

    In this study, the feasibility of developing Alyssum homolocarpum seed gum (AHSG) nanocapsules containing d-limonene by electrospraying has been investigated. d-limonene emulsions with constant AHSG (0.5% w/w) and various flavor concentrations (10-30% based on gum weight) with 0.1% Tween 20 were electrosprayed at 20kV and 0.1ml/h of flow rate. The effects of key parameters of emulsions (rheological properties, droplet size, surface tension and electrical conductivity) on the morphology of structures have been studied. The morphology of nanocapsules had strong dependency on solution properties. The aggregated irregular shaped nanoparticles were obtained from electrospraying of AHSG solution. After incorporation of 10 and 20% d-limonene, spherical nanocapsules were yielded. However, morphology of nanocapsules changed to nanofibers by increasing the flavor content to 30%. The encapsulation efficiency for 10 and 20% d-limonene loaded nanocapsules was around 87-93%. Attenuated total reflectance-fourier transform infrared spectroscopy (ATR-FTIR), X-ray diffraction (XRD), differential scanning calorimetry (DSC), and thermogravimetric analysis (TGA) were also employed to study the physicochemical characteristics of nanocapsules. These experiments provided evidences that electrosprayed AHSG nanoparticles introduce a novel and efficient carrier for encapsulation of bioactive ingredients. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Super-hydrophobic coatings based on non-solvent induced phase separation during electro-spraying.

    PubMed

    Gao, Jiefeng; Huang, Xuewu; Wang, Ling; Zheng, Nan; Li, Wan; Xue, Huaiguo; Li, Robert K Y; Mai, Yiu-Wing

    2017-11-15

    The polymer solution concentration determines whether electrospinning or electro-spraying occurs, while the addition of the non-solvent into the polymer solution strongly influences the surface morphology of the obtained products. Both smooth and porous surfaces of the electro-sprayed microspheres can be harvested by choosing different non-solvent and its amount as well as incorporating polymeric additives. The influences of the solution concentration, weight ratio between the non-solvent and the copolymer, and the polymeric additives on the surface morphology and the wettability of the electro-sprayed products were systematically studied. Surface pores and/or asperities on the microsphere surface were mainly caused by the non-solvent induced phase separation (NIPS) and subsequent evaporation of the non-solvent during electro-spraying. With increasing polymer solution concentration, the microsphere was gradually changed to the bead-on-string geometry and finally to a nanofiber form, leading to a sustained decrease of the contact angle (CA). It was found that the substrate coatings derived from the microspheres possessing hierarchical surface pores or dense asperities had high surface roughness and super-hydrophobicity with CAs larger than 150° while sliding angles smaller than 10°; but coatings composed of microspheres with smooth surfaces gave relatively low CAs. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Transformation of cyclodextrin glucanotransferase (CGTase) from aqueous suspension to fine solid particles via electrospraying.

    PubMed

    Saallah, Suryani; Naim, M Nazli; Mokhtar, Mohd Noriznan; Abu Bakar, Noor Fitrah; Gen, Masao; Lenggoro, I Wuled

    2014-10-01

    In this study, the potential of electrohydrodynamic atomization or electrospraying to produce nanometer-order CGTase particles from aqueous suspension was demonstrated. CGTase enzyme was prepared in acetate buffer solution (1% v/v), followed by electrospraying in stable Taylor cone-jet mode. The deposits were collected on aluminium foil (collector) at variable distances from the tip of spraying needle, ranging from 10 to 25 cm. The Coulomb fission that occurs during electrospraying process successfully transformed the enzyme to the solid state without any functional group deterioration. The functional group verification was conducted by FTIR analysis. Comparison between the deposit and the as-received enzyme in dry state indicates almost identical spectra. By increasing the distance of the collector from the needle tip, the average particle size of the solidified enzyme was reduced from 200±117 nm to 75±34 nm. The average particle sizes produced from the droplet fission were in agreement with the scaling law models. Enzyme activity analysis showed that the enzyme retained its initial activity after the electrospraying process. The enzyme particles collected at the longest distance (25 cm) demonstrated the highest enzyme activity, which indicates that the activity was controlled by the enzyme particle size. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Real-time measurement of UV-inactivated Escherichia coli bacterial particles by electrospray-assisted UVAPS spectrometry.

    PubMed

    Jung, Jae Hee; Lee, Jung Eun; Bae, Gwi Nam

    2011-08-01

    The ultraviolet aerodynamic particle sizer (UVAPS) is a novel commercially available aerosol spectrometer for real-time continuous monitoring of viable bioaerosols, based on fluorescence from living microorganisms. In a previous study, we developed an electrospray-assisted UVAPS using biological electrospray techniques, which have the advantage of generating non-agglomerated single particles by the repulsive electrical forces. With this electrospraying of suspensions containing microorganisms, the analytical system can supply more accurate and quantitative information about living microorganisms than with conventional aerosolization. Using electrospray-assisted UVAPS, we investigated the characteristics of bacterial particles with various viabilities in real-time. Escherichia coli was used as the test microorganism, and its initial viability was controlled by the degree of exposure to UV irradiation. In the stable cone-jet domain, the particle size distributions of test bacterial particles remained almost uniform regardless of the degree of UV inactivation. However, the fluorescence spectra of the bacterial particles changed with the degree of UV inactivation. The fluorescence characteristics of UV-inactivated bacterial particles tended to show a similar decline with viability, determined by the sampling and culture method, although the percentage showing fluorescence was higher than that showing viability. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Conversions of formaldehyde-modified 2'-deoxyadenosine 5'-monophosphate in conditions modeling formalin-fixed tissue dehydration.

    PubMed

    Rait, Vladimir K; Zhang, Qingrong; Fabris, Daniele; Mason, Jeffrey T; O'Leary, Timothy J

    2006-03-01

    Formalin-fixed, paraffin-embedded specimens typically provide molecular biologists with low yields of extractable nucleic acids that exhibit extensive strand cleavage and covalent modification of nucleic acid bases. This study supports the idea that these deleterious effects are promoted by the first step in formalin-fixed tissue processing--i.e., tissue dehydration with a graded series of alcohols. We analyzed the conversions of formaldehyde-modified 2'-deoxyadenosine 5'-monophosphate (dAMP) by reverse-phase ion-pair, high-performance liquid chromatography and found that dehydration does not stabilize N-methylol groups in the modified nucleotide. Furthermore, spontaneous demodification in a dry state or in anhydrous ethanol can be as fast as it is in aqueous solutions if the preparation is contaminated with salts of orthophosphoric acid. In ethanol, orthophosphates also catalyze formation of abundant N6-ethoxymethyl-dAMP, as well as cross-linking and depurination of nucleotides present in the mixture. Identification of the products was performed using ultraviolet absorbance spectroscopy and electrospray ionization Fourier-transform ion cyclotron resonance mass spectrometry. Alternatives to the traditional processing of formalin-fixed tissues are discussed.

  20. IR-MALDESI MASS SPECTROMETRY IMAGING OF BIOLOGICAL TISSUE SECTIONS USING ICE AS A MATRIX

    PubMed Central

    Robichaud, Guillaume; Barry, Jeremy A.; Muddiman, David C.

    2014-01-01

    Infrared Matrix-Assisted Laser Desorption Electrospray Ionization (IR-MALDESI) Mass Spectrometry imaging of biological tissue sections using a layer of deposited ice as an energy absorbing matrix was investigated. Dynamics of plume ablation were first explored using a nanosecond exposure shadowgraphy system designed to simultaneously collect pictures of the plume with a camera and collect the FT-ICR mass spectrum corresponding to that same ablation event. Ablation of fresh tissue analyzed with and without using ice as a matrix were both compared using this technique. Effect of spot-to-spot distance, number of laser shots per pixel and tissue condition (matrix) on ion abundance was also investigated for 50 µm thick tissue sections. Finally, the statistical method called design of experiments was used to compare source parameters and determine the optimal conditions for IR-MALDESI of tissue sections using deposited ice as a matrix. With a better understanding of the fundamentals of ablation dynamics and a systematic approach to explore the experimental space, it was possible to improve ion abundance by nearly one order of magnitude. PMID:24385399

  1. UV action spectroscopy of protonated PAH derivatives. Methyl substituted quinolines

    NASA Astrophysics Data System (ADS)

    Klærke, B.; Holm, A. I. S.; Andersen, L. H.

    2011-08-01

    Aims: We investigate the production of molecular photofragments upon UV excitation of PAH derivatives, relevant for the interstellar medium. Methods: The action absorption spectra of protonated gas-phase methyl-substituted quinolines (CH3 - C9H7NH+) have been recorded in the 215-338 nm spectral range using the electrostatic storage ring ELISA, an electrospray ion source and 3 ns UV laser pulses. Results: It is shown that the absorption profile is both redshifted and broadened when moving the methyl group from the heterocycle containing nitrogen to the homoatomic ring. The absorption profiles are explained by TD-DFT calculations. The dissociation time of the studied molecules is found to be of several milliseconds at 230 nm and it is shown that after redistribution of the absorbed energy the molecules dissociate in several channels. The dissociation time found is an order of magnitude faster than the estimated IR relaxation time. Photophysical properties of both nitrogen containing and methyl-substituted PAHs are interesting in an astrophysical context in connection with identifying the aromatic component of the interstellar medium.

  2. Impact of absorption in the top layer of a two layer sample on spectroscopic spectral domain interferometry of the bottom layer

    NASA Astrophysics Data System (ADS)

    Fleischhauer, F.; Feuchter, T.; Leick, L.; Rajendram, R.; Podoleanu, A.

    2018-03-01

    Spectroscopic spectral domain interferometry and spectroscopic optical coherence tomography combine depth information with spectrally-resolved localised absorption data. These additional data can improve diagnostics by giving access to functional information of the investigated sample. One possible application is measuring oxygenation levels at the retina for earlier detection of several eye diseases. Here measurements with different hollow glass tube phantoms are shown to measure the impact of a superficial absorbing layer on the precision of reconstructed attenuation spectra of a deeper layer. Measurements show that a superficial absorber has no impact on the reconstructed absorption spectrum of the deeper absorber. Even when diluting the concentration of the deeper absorber so far that an incorrect absorption maximum is obtained, still no influence of the superficially placed absorber is identified.

  3. COBALT-60 Gamma Irradiation of Shrimp.

    NASA Astrophysics Data System (ADS)

    Sullivan, Nancy L. B.

    Meta- and ortho-tyrosine were measured using high performance liquid chromatography (HPLC) in conjunction with electrochemical detection in shrimp irradiated using cobalt-60 gamma radiation in the absorbed dose range 0.8 to 6.0 kGy, in nonirradiated shrimp, and in bovine serum albumin (BSA) irradiated in dilute aqueous solution at 25.0 kGy. Ortho-tyrosine was measured in nonirradiated BSA. Para-, meta-, and ortho-tyrosine were measured using HPLC in conjunction with uv-absorption detection in dilute aqueous solutions of phenylalanine irradiated in the absorbed dose range 16.0 to 195.0 kGy. The measured yields of tyrosine isomers were approximately linear as a function of absorbed dose in shrimp, and in irradiated solutions of phenylalanine up to 37.0 kGy. The occurrence of meta- and ortho-tyrosine, which had formerly been considered unique radiolytic products, has not previously been reported in nonirradiated shrimp or BSA. The conventional hydrolyzation and analytical techniques used in the present study to measure meta- and ortho-tyrosine may provide the basis for a method to detect and determine the dose used in food irradiation.

  4. Molecular Characterization of Thiols in Fossil Fuels by Michael Addition Reaction Derivatization and Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry.

    PubMed

    Wang, Meng; Zhao, Suoqi; Liu, Xuxia; Shi, Quan

    2016-10-04

    Thiols widely occur in sediments and fossil fuels. However, the molecular composition of these compounds is unclear due to the lack of appropriate analytical methods. In this work, a characterization method for thiols in fossil fuels was developed on the basis of Michael addition reaction derivatization followed by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FT-ICR MS). Model thiol compound studies showed that thiols were selectively reacted with phenylvinylsulfone and transformed to sulfones with greater than 98% conversions. This method was applied to a coker naphtha, light and heavy gas oils, and crude oils from various geological sources. The results showed that long alkyl chain thiols are readily present in petroleum, which have up to 30 carbon atoms. Large DBE dispersity of thiols indicates that naphthenic and aromatic thiols are also present in the petroleum. This method is capable of detecting thiol compounds in the part per million range by weight. This method allows characterization of thiols in a complex hydrocarbon matrix, which is complementary to the comprehensive analysis of sulfur compounds in fossil fuels.

  5. Ammonium Bicarbonate Addition Improves the Detection of Proteins by Desorption Electrospray Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Honarvar, Elahe; Venter, Andre R.

    2017-06-01

    The analysis of protein by desorption electrospray ionization mass spectrometry (DESI-MS) is considered impractical due to a mass-dependent loss in sensitivity with increase in protein molecular weights. With the addition of ammonium bicarbonate to the DESI-MS analysis the sensitivity towards proteins by DESI was improved. The signal to noise ratio (S/N) improvement for a variety of proteins increased between 2- to 3-fold relative to solvent systems containing formic acid and more than seven times relative to aqueous methanol spray solvents. Three methods for ammonium bicarbonate addition during DESI-MS were investigated. The additive delivered improvements in S/N whether it was mixed with the analyte prior to sample deposition, applied over pre-prepared samples, or simply added to the desorption spray solvent. The improvement correlated well with protein pI but not with protein size. Other ammonium or bicarbonate salts did not produce similar improvements in S/N, nor was this improvement in S/N observed for ESI of the same samples. As was previously described for ESI, DESI also caused extensive protein unfolding upon the addition of ammonium bicarbonate. [Figure not available: see fulltext.

  6. Assignment by Negative-Ion Electrospray Tandem Mass Spectrometry of the Tetrasaccharide Backbones of Monosialylated Glycans Released from Bovine Brain Gangliosides

    NASA Astrophysics Data System (ADS)

    Chai, Wengang; Zhang, Yibing; Mauri, Laura; Ciampa, Maria G.; Mulloy, Barbara; Sonnino, Sandro; Feizi, Ten

    2018-05-01

    Gangliosides, as plasma membrane-associated sialylated glycolipids, are antigenic structures and they serve as ligands for adhesion proteins of pathogens, for toxins of bacteria, and for endogenous proteins of the host. The detectability by carbohydrate-binding proteins of glycan antigens and ligands on glycolipids can be influenced by the differing lipid moieties. To investigate glycan sequences of gangliosides as recognition structures, we have underway a program of work to develop a "gangliome" microarray consisting of isolated natural gangliosides and neoglycolipids (NGLs) derived from glycans released from them, and each linked to the same lipid molecule for arraying and comparative microarray binding analyses. Here, in the first phase of our studies, we describe a strategy for high-sensitivity assignment of the tetrasaccharide backbones and application to identification of eight of monosialylated glycans released from bovine brain gangliosides. This approach is based on negative-ion electrospray mass spectrometry with collision-induced dissociation (ESI-CID-MS/MS) of the desialylated glycans. Using this strategy, we have the data on backbone regions of four minor components among the monosialo-ganglioside-derived glycans; these are of the ganglio-, lacto-, and neolacto-series.

  7. Cytosine to uracil conversion through hydrolytic deamination of cytidine monophosphate hydroxy-alkylated on the amino group: a liquid chromatography--electrospray ionization--mass spectrometry investigation.

    PubMed

    Losito, I; Angelico, R; Introna, B; Ceglie, A; Palmisano, F

    2012-10-01

    A novel pathway for cytosine to uracil conversion performed in a micellar environment, leading to the generation of uridine monophosphate (UMP), was evidenced during the alkylation reaction of cytidine monophosphate (CMP) by dodecyl epoxide. Liquid chromatography-electrospray ionization - ion trap - mass spectrometry was used to separate and identify the reaction products and to follow their formation over time. The detection of hydroxy-amino-dodecane, concurrently with free UMP, in the reaction mixture suggested that, among the various alkyl-derivatives formed, CMP alkylated on the amino group of cytosine could undergo tautomerization to an imine and hydrolytic deamination, generating UMP. Interestingly, no evidence for this peculiar conversion pathway was obtained when guanosine monophosphate (GMP), the complementary ribonucleotide of CMP, was also present in the reaction mixture, due to the fact that NH(2)-alkylated CMP was not formed in this case. The last finding emphasized the role played by CMP-GMP molecular interactions, mediated by a micellar environment, in hindering the alkylation reaction at the level of the cytosine amino group. Copyright © 2012 John Wiley & Sons, Ltd.

  8. Characterisation of chemical components for identifying historical Chinese textile dyes by ultra high performance liquid chromatography - photodiode array - electrospray ionisation mass spectrometer.

    PubMed

    Han, Jing; Wanrooij, Jantien; van Bommel, Maarten; Quye, Anita

    2017-01-06

    This research makes the first attempt to apply Ultra High Performance Liquid Chromatography (UHPLC) coupled to both Photodiode Array detection (PDA) and Electrospray Ionisation Mass Spectrometer (ESI-MS) to the chemical characterisation of common textile dyes in ancient China. Three different extraction methods, respectively involving dimethyl sulfoxide (DMSO)-oxalic acid, DMSO and hydrochloric acid, are unprecedentedly applied together to achieve an in-depth understanding of the chemical composition of these dyes. The first LC-PDA-MS database of the chemical composition of common dyes in ancient China has been established. The phenomena of esterification and isomerisation of the dye constituents of gallnut, gardenia and saffron, and the dye composition of acorn cup dyed silk are clarified for the first time. 6-Hydroxyrubiadin and its glycosides are first reported on a dyed sample with Rubia cordifolia from China. UHPLC-PDA-ESI-MS with a C18 BEH shield column shows significant advantages in the separation and identification of similar dye constituents, particularly in the cases of analysing pagoda bud and turmeric dyed sample extracts. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Analysis of iodinated haloacetic acids in drinking water by reversed-phase liquid chromatography/electrospray ionization/tandem mass spectrometry with large volume direct aqueous injection.

    PubMed

    Li, Yongtao; Whitaker, Joshua S; McCarty, Christina L

    2012-07-06

    A large volume direct aqueous injection method was developed for the analysis of iodinated haloacetic acids in drinking water by using reversed-phase liquid chromatography/electrospray ionization/tandem mass spectrometry in the negative ion mode. Both the external and internal standard calibration methods were studied for the analysis of monoiodoacetic acid, chloroiodoacetic acid, bromoiodoacetic acid, and diiodoacetic acid in drinking water. The use of a divert valve technique for the mobile phase solvent delay, along with isotopically labeled analogs used as internal standards, effectively reduced and compensated for the ionization suppression typically caused by coexisting common inorganic anions. Under the optimized method conditions, the mean absolute and relative recoveries resulting from the replicate fortified deionized water and chlorinated drinking water analyses were 83-107% with a relative standard deviation of 0.7-11.7% and 84-111% with a relative standard deviation of 0.8-12.1%, respectively. The method detection limits resulting from the external and internal standard calibrations, based on seven fortified deionized water replicates, were 0.7-2.3 ng/L and 0.5-1.9 ng/L, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Time-resolved method to distinguish protein/peptide oxidation during electrospray ionization mass spectrometry.

    PubMed

    Pei, Jiying; Hsu, Cheng-Chih; Yu, Kefu; Wang, Yinghui; Huang, Guangming

    2018-06-29

    Electrospray ionization mass spectrometry (ESI-MS) is one of the most prevalent techniques used to monitor protein/peptide oxidation induced by reactive oxygen species (ROSs). However, both corona discharge (CD) and electrochemistry (EC) can also lead to protein/peptide oxidation during ESI. Because the two types of oxidation occur almost simultaneously, determining the extent to which the two pathways contribute to protein/peptide oxidation is difficult. Herein, a time-resolved method was introduced to identify and differentiate CD- and EC-induced oxidation. Using this approach, we separated the instantaneous CD-induced oxidation from the hysteretic EC-induced oxidation, and the effects of the spray voltage and flow rate of the ESI source on both oxidation types were investigated with a homemade ESI source. For angiotensin II analogue (b-DRVYVHPF-y), the dehydrogenation and oxygenation species were the detected EC-induced oxidation products, while the oxygenation species were the major CD-induced oxidation products. This time-resolved approach was also applicable to a commercial HESI source, in which both CD and EC were responsible for hemoglobin and cytochrome c oxidation with upstream grounding while CD dominated the oxidation without upstream grounding. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Evaluation and performance of desorption electrospray ionization using a triple quadrupole mass spectrometer for quantitation of pharmaceuticals in plasma.

    PubMed

    Kennedy, Joseph H; Wiseman, Justin M

    2010-02-01

    The present work describes the methodology and investigates the performance of desorption electrospray ionization (DESI) combined with a triple quadrupole mass spectrometer for the quantitation of small drug molecules in human plasma. Amoxepine, atenolol, carbamazepine, clozapine, prazosin, propranolol and verapamil were selected as target analytes while terfenadine was selected as the internal standard common to each of the analytes. Protein precipitation of human plasma using acetonitrile was utilized for all samples. Limits of detection were determined for all analytes in plasma and shown to be in the range 0.2-40 ng/mL. Quantitative analysis of amoxepine, prazosin and verapamil was performed over the range 20-7400 ng/mL and shown to be linear in all cases with R(2) >0.99. In most cases, the precision (relative standard deviation) and accuracy (relative error) of each method were less than or equal to 20%, respectively. The performance of the combined techniques made it possible to analyze each sample in 15 s illustrating DESI tandem mass spectrometry (MS/MS) as powerful tool for the quantitation of analytes in deproteinized human plasma. Copyright 2010 John Wiley & Sons, Ltd.

  12. Quantitation of phlorizin and phloretin using an ultra high performance liquid chromatography-electrospray ionization tandem mass spectrometric method.

    PubMed

    Lijia, Xu; Guo, Jianru; Chen, QianQian; Baoping, Jiang; Zhang, Wei

    2014-06-01

    A sensitive and selective ultra high performance liquid chromatography-tandem mass spectrometric (UHPLC-MS/MS) method for the determination of phlorizin and phloretin in human plasma has been firstly developed. Samples were prepared after protein precipitation and analyzed on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. Negative electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile-water (0.02% formic acid), using a gradient procedure. The analytes and internal standard dihydroquercetin were both detected by use of multiple reaction monitoring mode. The method was linear in the concentration range of 2.5-1000.0 ng/mL. The lower limit of quantification (LLOQ) was 2.5 ng/mL. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 9.2%. The accuracy determined at three concentrations was within ± 7.3% in terms of relative error. The total run time was 12.0 min. This assay offers advantages in terms of expediency, and suitability for the analysis of phlorizin and phloretin in various biological fluids. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Metabolic profiling of rat hair and screening biomarkers using ultra performance liquid chromatography with electrospray ionization time-of-flight mass spectrometry.

    PubMed

    Inagaki, Shinsuke; Noda, Takumi; Min, Jun Zhe; Toyo'oka, Toshimasa

    2007-12-28

    An exhaustive analysis of metabolites in hair samples has been performed for the first time using ultra performance liquid chromatography with electrospray ionization time-of-flight mass spectrometry (UPLC-ESI-TOF-MS). The hair samples were collected from spontaneously hypertensive model rats (SHR/Izm), stroke-prone SHR (SHRSP/Izm) and Wistar Kyoto (WKY/Izm) rats, and were analyzed by UPLC-ESI-TOF-MS; a multivariate statistical analysis method, such as the principal component analysis (PCA), was then used for screening the biomarkers. From the samples derived from the group of SHRSP/Izm at weeks 10, 18, 26 and 34, we successfully detected a potential biomarker of stroke, which existed at much higher concentrations as compared with that in the other groups. However, a significant difference could not be found at weeks less than 7 before the rats were subjected to stroke and hypertension. In addition, the present method was applicable to screening not only the disease markers, but also the markers related to aging. The method utilizing hair samples is expected to be quite useful for screening biomarkers of many other diseases, and not limited to stroke and hypertension.

  14. PCR Followed by Electrospray Ionization Mass Spectrometry for Broad-Range Identification of Fungal Pathogens

    PubMed Central

    Massire, Christian; Buelow, Daelynn R.; Zhang, Sean X.; Lovari, Robert; Matthews, Heather E.; Toleno, Donna M.; Ranken, Raymond R.; Hall, Thomas A.; Metzgar, David; Sampath, Rangarajan; Blyn, Lawrence B.; Ecker, David J.; Gu, Zhengming; Walsh, Thomas J.

    2013-01-01

    Invasive fungal infections are a significant cause of morbidity and mortality among immunocompromised patients. Early and accurate identification of these pathogens is central to direct therapy and to improve overall outcome. PCR coupled with electrospray ionization mass spectrometry (PCR/ESI-MS) was evaluated as a novel means for identification of fungal pathogens. Using a database grounded by 60 ATCC reference strains, a total of 394 clinical fungal isolates (264 molds and 130 yeasts) were analyzed by PCR/ESI-MS; results were compared to phenotypic identification, and discrepant results were sequence confirmed. PCR/ESI-MS identified 81.4% of molds to either the genus or species level, with concordance rates of 89.7% and 87.4%, respectively, to phenotypic identification. Likewise, PCR/ESI-MS was able to identify 98.4% of yeasts to either the genus or species level, agreeing with 100% of phenotypic results at both the genus and species level. PCR/ESI-MS performed best with Aspergillus and Candida isolates, generating species-level identification in 94.4% and 99.2% of isolates, respectively. PCR/ESI-MS is a promising new technology for broad-range detection and identification of medically important fungal pathogens that cause invasive mycoses. PMID:23303501

  15. Spatially resolved investigation of systemic and contact pesticides in plant material by desorption electrospray ionization mass spectrometry imaging (DESI-MSI).

    PubMed

    Gerbig, Stefanie; Brunn, Hubertus E; Spengler, Bernhard; Schulz, Sabine

    2015-09-01

    Distribution of pesticides both on the surface of leaves and in cross sections of plant stem and leaves was investigated using desorption electrospray ionization mass spectrometry imaging (DESI-MSI) with a spatial resolution of 50-100 μm. Two commercially available insecticide sprays containing different contact pesticides were applied onto leaves of Cotoneaster horizontalis, and the distributions of all active ingredients were directly analyzed. The first spray contained pyrethrins and rapeseed oil, both known as natural insecticides. Each component showed an inhomogeneous spreading throughout the leaf, based on substance polarity and solubility. The second spray contained the synthetic insecticides imidacloprid and methiocarb. Imidacloprid accumulated on the border of the leaf, while methiocarb was distributed more homogenously. In order to investigate the incorporation of a systemically acting pesticide into Kalanchoe blossfeldiana, a commercially available insecticide tablet containing dimethoate was spiked to the soil of the plant. Cross sections of the stem and leaf were obtained 25 and 60 days after application. Dimethoate was mainly detected in the transport system of the plant after 25 days, while it was found to be homogenously distributed in a leaf section after 60 days.

  16. Determination of benzotriazole corrosion inhibitors from aqueous environmental samples by liquid chromatography-electrospray ionization-tandem mass spectrometry.

    PubMed

    Weiss, Stefan; Reemtsma, Thorsten

    2005-11-15

    The first method for the determination of commonly used corrosion inhibitors in environmental water samples by liquid chromatography-electrospray ionization-tandem mass spectrometry is presented. Benzotriazole (BTri) and the two isomers of tolyltriazole (5- and 4-TTri) are separated in an isocratic run. By gradient elution, BTri, 4-TTri, 5-TTri, and xylyltriazole can be determined simultaneously with three benzothiazoles, but here TTri isomers coelute. The instrumental detection limit of 2 pg allows the determination of the three most important benzotriazoles from municipal wastewater and most surface waters by direct injection into the HPLC system without previous enrichment. When solid-phase extraction is employed with mean recovery rates of 95-113%, the limit of quantification for benzotriazoles range from 10 ng/L in groundwater to 25 ng/L in untreated wastewater. BTri and TTri were determined in municipal wastewater in microgram per liter concentrations. Elimination in wastewater treatment appears to be poor, and BTri and TTri can be followed through a water cycle from treated municipal wastewater through surface water to bank filtrate used for drinking water production. The TTri isomers show markedly different biodegradation behavior with 4-TTri being more stable.

  17. Polymerase Chain Reaction-Electrospray-Time-of-Flight Mass Spectrometry Versus Culture for Bacterial Detection in Septic Arthritis and Osteoarthritis.

    PubMed

    Palmer, Michael P; Melton-Kreft, Rachael; Nistico, Laura; Hiller, N Louisa; Kim, Leon H J; Altman, Gregory T; Altman, Daniel T; Sotereanos, Nicholas G; Hu, Fen Z; De Meo, Patrick J; Ehrlich, Garth D

    2016-12-01

    Preliminary studies have identified known bacterial pathogens in the knees of patients with osteoarthritis (OA) before arthroplasty. The current study was designed to determine the incidence and types of bacteria present in the synovial fluid of native knee joints from adult patients with diagnoses of septic arthritis and OA. Patients were enrolled between October 2010 and January 2013. Synovial fluid samples from the affected knee were collected and evaluated with both traditional microbial culture and polymerase chain reaction-electrospray ionization-time-of-flight mass spectrometry (molecular diagnostics [MDx]) to prospectively characterize the microbial content. Patients were grouped by diagnosis into one of two cohorts, those with clinical suspicion of septic arthritis (n = 44) and those undergoing primary arthroplasty of the knee for OA (n = 21). In all cases where discrepant culture and MDx results were obtained, we performed species-specific 16S rRNA fluorescence in situ hybridization (FISH) as a confirmatory test. MDx testing identified bacteria in 50% of the suspected septic arthritis cases and 29% of the arthroplasty cases, whereas culture detected bacteria in only 16% of the former and 0% of the latter group. The overall difference in detection rates for culture and MDx was very highly significant, p-value = 2.384 × 10 -7 . All of the culture-positive cases were typed as Staphylococcus aureus. Two of the septic arthritis cases were polymicrobial as was one of the OA cases by MDx. FISH testing of the specimens with discordant results supported the MDx findings in 91% (19/21) of the cases, including one case where culture detected S. aureus and MDx detected Streptococcus agalactiae. MDx were more sensitive than culture, as confirmed by FISH. FISH only identifies bacteria that are embedded or infiltrated within the tissue and is thus not susceptible to contamination. Not all suspected cases of septic arthritis contain bacteria, but a significant percent of patients with OA, and no signs of infection, have FISH-confirmed bacterial biofilms present in the knee.

  18. STRUCTURAL DETERMINATION AND QUANTITATIVE ANALYSIS OF BACTERIAL PHOSPHOLIPIDS USING LIQUID CHROMATOGRAPHY/ELECTROSPRAY IONIZATION/MASS SPECTROMETRY

    EPA Science Inventory

    This report presents a comprehensive spectral analysis of common bacterial phospholipids using electrospray/mass spectrometry (ESI/MS) under both negative and positive ionization conditions. Phospholipids under positive ionization yield sodium-adduct molecular ions which are mos...

  19. Simulation, fabrication and characterization of THz metamaterial absorbers.

    PubMed

    Grant, James P; McCrindle, Iain J H; Cumming, David R S

    2012-12-27

    Metamaterials (MM), artificial materials engineered to have properties that may not be found in nature, have been widely explored since the first theoretical(1) and experimental demonstration(2) of their unique properties. MMs can provide a highly controllable electromagnetic response, and to date have been demonstrated in every technologically relevant spectral range including the optical(3), near IR(4), mid IR(5) , THz(6) , mm-wave(7) , microwave(8) and radio(9) bands. Applications include perfect lenses(10), sensors(11), telecommunications(12), invisibility cloaks(13) and filters(14,15). We have recently developed single band(16), dual band(17) and broadband(18) THz metamaterial absorber devices capable of greater than 80% absorption at the resonance peak. The concept of a MM absorber is especially important at THz frequencies where it is difficult to find strong frequency selective THz absorbers(19). In our MM absorber the THz radiation is absorbed in a thickness of ~ λ/20, overcoming the thickness limitation of traditional quarter wavelength absorbers. MM absorbers naturally lend themselves to THz detection applications, such as thermal sensors, and if integrated with suitable THz sources (e.g. QCLs), could lead to compact, highly sensitive, low cost, real time THz imaging systems.

  20. Wireless system for explosion detection in underground structures

    NASA Astrophysics Data System (ADS)

    Chikhradze, M.; Bochorishvili, N.; Akhvlediani, I.; Kukhalashvili, D.; Kalichava, I.; Mataradze, E.

    2009-06-01

    Considering the growing threat of terrorist or accidental explosions in underground stations, underground highway and railway sections improvement of system for protecting people from explosions appears urgent. Current automatic protective devices with blast identification module and blast damping absorbers of various designs as their basic elements cannot be considered effective. Analysis revealed that low reliability of blast detection and delayed generation of start signal for the activation of an absorber are the major disadvantages of protective devices. Besides the transmission of trigger signal to an energy absorber through cable communication reduces the reliability of the operation of protective device due to a possible damage of electric wiring under blast or mechanical attack. This paper presents the outcomes of the studies conducted to select accurate criteria for blast identification and to design wireless system of activation of defensive device. The results of testing of blast detection methods (seismic, EMP, optical, on overpressure) showed that the proposed method, which implies constant monitoring of overpressure in terms of its reliability and response speed, best meets the requirements. Proposed wireless system for explosions identification and activation of protective device consists of transmitter and receiver modules. Transmitter module contains sensor and microprocessor equipped with blast identification software. Receiver module produces activation signal for operation of absorber. Tests were performed in the underground experimental base of Mining Institute. The time between the moment of receiving signal by the sensor and activation of absorber - 640 microsecond; distance between transmitter and receiver in direct tunnel - at least 150m; in tunnel with 900 bending - 50m. This research is sponsored by NATO's Public Diplomacy Division in the framework of "Science for Peace".

Top