  1. Direct absorbed dose to water determination based on water calorimetry in scanning proton beam delivery

    SciTech Connect

    Sarfehnia, A.; Clasie, B.; Chung, E.; Lu, H. M.; Flanz, J.; Cascio, E.; Engelsman, M.; Paganetti, H.; Seuntjens, J.

    2010-07-15

    Purpose: The aim of this manuscript is to describe the direct measurement of absolute absorbed dose to water in a scanned proton radiotherapy beam using a water calorimeter primary standard. Methods: The McGill water calorimeter, which has been validated in photon and electron beams as well as in HDR {sup 192}Ir brachytherapy, was used to measure the absorbed dose to water in double scattering and scanning proton irradiations. The measurements were made at the Massachusetts General Hospital proton radiotherapy facility. The correction factors in water calorimetry were numerically calculated and various parameters affecting their magnitude and uncertainty were studied. The absorbed dose to water was compared to that obtained using an Exradin T1 Chamber based on the IAEA TRS-398 protocol. Results: The overall 1-sigma uncertainty on absorbed dose to water amounts to 0.4% and 0.6% in scattered and scanned proton water calorimetry, respectively. This compares to an overall uncertainty of 1.9% for currently accepted IAEA TRS-398 reference absorbed dose measurement protocol. The absorbed dose from water calorimetry agrees with the results from TRS-398 well to within 1-sigma uncertainty. Conclusions: This work demonstrates that a primary absorbed dose standard based on water calorimetry is feasible in scattered and scanned proton beams.

  2. Radioimmunotherapy treatment planning based on radiation absorbed dose or patient size

    SciTech Connect

    Eary, J.F.; Krohn, K.A.; Press, O.W. |

    1996-05-01

    Several approaches have been used to plan treatment doses for patients undergoing radioimmunotherapy. Investigators often use fixed doses, or doses based on patient size (mCi/kg or mCi/m{sup 2}). Our treatment protocols for lymphoma and leukemia involved calculation of tissue radiation absorbed dose based on images from a trace labeled infusion of antibody prior to treatment. In a recent analysis of patients treated in the Phase I and II dose escalation trial for treatment of non-Hodgkin`s lymphoma with I-131 anti-CD20 antibody (B1), we investigated the relationship between our dosimetry based treatment and dose based on patient size. Tissue radiation dose for several normal organs and for tumors were plotted versus the mCi administered per kg or m{sup 2} of the patient to evaluate the relationship between the two treatment approaches. These graphs showed correlation coefficients ranging from 0.021 to 0.684, demonstrating the variability in antibody catabolism between patients. This means that fixed doses or administrations based on patient size do not deliver consistent radiation doses to normal organs or tumors. This finding was extrapolated to show that toxicity from doses based on patient size di not correlate with treatment dose; those based on calculated rad/organ did. Phase I clinical trials using treatment doses based on patient size where there are likely to be variations in patient antibody catabolism will result in confounding toxicities at apparently similar mCi dose levels. Use of pre-treatment scans for treatment dose planning are worth the additional effort by normalizing the normal tissue toxicity.

  3. Specification of absorbed dose to water using model-based dose calculation algorithms for treatment planning in brachytherapy

    NASA Astrophysics Data System (ADS)

    Carlsson Tedgren, Åsa; Alm Carlsson, Gudrun

    2013-04-01

    Model-based dose calculation algorithms (MBDCAs), recently introduced in treatment planning systems (TPS) for brachytherapy, calculate tissue absorbed doses. In the TPS framework, doses have hereto been reported as dose to water and water may still be preferred as a dose specification medium. Dose to tissue medium Dmed then needs to be converted into dose to water in tissue Dw,med. Methods to calculate absorbed dose to differently sized water compartments/cavities inside tissue, infinitesimal (used for definition of absorbed dose), small, large or intermediate, are reviewed. Burlin theory is applied to estimate photon energies at which cavity sizes in the range 1 nm-10 mm can be considered small or large. Photon and electron energy spectra are calculated at 1 cm distance from the central axis in cylindrical phantoms of bone, muscle and adipose tissue for 20, 50, 300 keV photons and photons from 125I, 169Yb and 192Ir sources; ratios of mass-collision-stopping powers and mass energy absorption coefficients are calculated as applicable to convert Dmed into Dw,med for small and large cavities. Results show that 1-10 nm sized cavities are small at all investigated photon energies; 100 µm cavities are large only at photon energies <20 keV. A choice of an appropriate conversion coefficient Dw, med/Dmed is discussed in terms of the cavity size in relation to the size of important cellular targets. Free radicals from DNA bound water of nanometre dimensions contribute to DNA damage and cell killing and may be the most important water compartment in cells implying use of ratios of mass-collision-stopping powers for converting Dmed into Dw,med.

  4. Specification of absorbed dose to water using model-based dose calculation algorithms for treatment planning in brachytherapy.

    PubMed

    Tedgren, Åsa Carlsson; Carlsson, Gudrun Alm

    2013-04-21

    Model-based dose calculation algorithms (MBDCAs), recently introduced in treatment planning systems (TPS) for brachytherapy, calculate tissue absorbed doses. In the TPS framework, doses have hereto been reported as dose to water and water may still be preferred as a dose specification medium. Dose to tissue medium Dmed then needs to be converted into dose to water in tissue Dw,med. Methods to calculate absorbed dose to differently sized water compartments/cavities inside tissue, infinitesimal (used for definition of absorbed dose), small, large or intermediate, are reviewed. Burlin theory is applied to estimate photon energies at which cavity sizes in the range 1 nm-10 mm can be considered small or large. Photon and electron energy spectra are calculated at 1 cm distance from the central axis in cylindrical phantoms of bone, muscle and adipose tissue for 20, 50, 300 keV photons and photons from (125)I, (169)Yb and (192)Ir sources; ratios of mass-collision-stopping powers and mass energy absorption coefficients are calculated as applicable to convert Dmed into Dw,med for small and large cavities. Results show that 1-10 nm sized cavities are small at all investigated photon energies; 100 µm cavities are large only at photon energies <20 keV. A choice of an appropriate conversion coefficient Dw, med/Dmed is discussed in terms of the cavity size in relation to the size of important cellular targets. Free radicals from DNA bound water of nanometre dimensions contribute to DNA damage and cell killing and may be the most important water compartment in cells implying use of ratios of mass-collision-stopping powers for converting Dmed into Dw,med.

  5. Absorbed Dose Calculations Using Mesh-based Human Phantoms And Monte Carlo Methods

    NASA Astrophysics Data System (ADS)

    Kramer, Richard

    2011-08-01

    Health risks attributable to the exposure to ionizing radiation are considered to be a function of the absorbed or equivalent dose to radiosensitive organs and tissues. However, as human tissue cannot express itself in terms of equivalent dose, exposure models have to be used to determine the distribution of equivalent dose throughout the human body. An exposure model, be it physical or computational, consists of a representation of the human body, called phantom, plus a method for transporting ionizing radiation through the phantom and measuring or calculating the equivalent dose to organ and tissues of interest. The FASH2 (Female Adult meSH) and the MASH2 (Male Adult meSH) computational phantoms have been developed at the University of Pernambuco in Recife/Brazil based on polygon mesh surfaces using open source software tools and anatomical atlases. Representing standing adults, FASH2 and MASH2 have organ and tissue masses, body height and body mass adjusted to the anatomical data published by the International Commission on Radiological Protection for the reference male and female adult. For the purposes of absorbed dose calculations the phantoms have been coupled to the EGSnrc Monte Carlo code, which can transport photons, electrons and positrons through arbitrary media. This paper reviews the development of the FASH2 and the MASH2 phantoms and presents dosimetric applications for X-ray diagnosis and for prostate brachytherapy.

  6. MO-AB-BRA-03: Calorimetry-Based Absorbed Dose to Water Measurements Using Interferometry

    SciTech Connect

    Flores-Martinez, E; Malin, M; DeWerd, L

    2015-06-15

    Purpose: Interferometry-based calorimetry is a novel technique to measure radiation-induced temperature changes allowing the measurement of absorbed dose to water (ADW). There are no mechanical components in the field. This technique also has the possibility of obtaining 2D dose distributions. The goal of this investigation is to calorimetrically-measure doses between 2.5 and 5 Gy over a single projection in a photon beam using interferometry and compare the results with doses calculated using the TG-51 linac calibration. Methods: ADW was determined by measuring radiation-induced phase shifts (PSs) of light passing through water irradiated with a 6 MV photon beam. A 9×9×9 cm{sup 3} glass phantom filled with water and placed in an arm of a Michelson interferometer was irradiated with 300, 400, 500 and 600 monitor units. The whole system was thermally insulated to achieve sufficient passive temperature control. The depth of measurement was 4.5 cm with a field size of 7×7 cm{sup 2}. The intensity of the fringe pattern was monitored with a photodiode and used to calculate the time-dependent PS curve. Data was acquired 60 s before and after the irradiation. The radiation-induced PS was calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. Results were compared to computed doses. Results: Average comparison of calculated ADW values with interferometry-measured values showed an agreement to within 9.5%. k=1 uncertainties were 4.3% for calculations and 14.7% for measurements. The dominant source of uncertainty for the measurements was a temperature drift of about 30 µK/s caused by heat conduction from the interferometer’s surroundings. Conclusion: This work presented the first absolute ADW measurements using interferometry in the dose range of linac-based radiotherapy. Future work to improve measurements’ reproducibility includes the implementation of active thermal control techniques.

  7. Absorbed dose estimates to structures of the brain and head using a high-resolution voxel-based head phantom.

    PubMed

    Evans, J F; Blue, T E; Gupta, N

    2001-05-01

    The purpose of this article is to demonstrate the viability of using a high-resolution 3-D head phantom in Monte Carlo N-Particle (MCNP) for boron neutron capture therapy (BNCT) structure dosimetry. This work describes a high-resolution voxel-based model of a human head and its use for calculating absorbed doses to the structures of the brain. The Zubal head phantom is a 3-D model of a human head that can be displayed and manipulated on a computer. Several changes were made to the original head phantom which now contains over 29 critical structures of the brain and head. The modified phantom is a 85 x 109 x 120 lattice of voxels, where each voxel is 2.2 x 2.2 x 1.4 mm3. This model was translated into MCNP lattice format. As a proof of principle study, two MCNP absorbed dose calculations were made (left and right lateral irradiations) using a uniformly distributed neutron disk source with an 1/E energy spectrum. Additionally, the results of these two calculations were combined to estimate the absorbed doses from a bilateral irradiation. Radiobiologically equivalent (RBE) doses were calculated for all structures and were normalized to 12.8 Gy-Eq. For a left lateral irradiation, the left motor cortex receives the limiting RBE dose. For a bilateral irradiation, the insula cortices receive the limiting dose. Among the nonencephalic structures, the parotid glands receive RBE doses that were within 15% of the limiting dose.

  8. [Absorbed doses in dental radiology].

    PubMed

    Bianchi, S D; Roccuzzo, M; Albrito, F; Ragona, R; Anglesio, S

    1996-01-01

    The growing use of dento-maxillo-facial radiographic examinations has been accompanied by the publication of a large number of studies on dosimetry. A thorough review of the literature is presented in this article. Most studies were carried out on tissue equivalent skull phantoms, while only a few were in vivo. The aim of the present study was to evaluate in vivo absorbed doses during Orthopantomography (OPT). Full Mouth Periapical Examination (FMPE) and Intraoral Tube Panoramic Radiography (ITPR). Measurements were made on 30 patients, reproducing clinical conditions, in 46 anatomical sites, with 24 intra- and 22 extra-oral thermoluminiscent dosimeters (TLDS). The highest doses were measured, in orthopantomography, at the right mandibular angle (1899 mu Gy) in FMPE on the right naso-labial fold (5640 mu Gy and in ITPR on the palatal surface of the left second upper molar (1936 mu Gy). Intraoral doses ranged from 21 mu Gy, in orthopantomography, to 4494 mu Gy in FMPE. Standard errors ranged from 142% in ITPR to 5% in orthopantomography. The highest rate of standard errors was found in FMPE and ITPR. The data collected in this trial are in agreement with others in major literature reports. Disagreements are probably due to different exam acquisition and data collections. Such differences, presented comparison in several sites, justify lower doses in FMPE and ITPR. Advantages and disadvantages of in vivo dosimetry of the maxillary region are discussed, the former being a close resemblance to clinical conditions of examination and the latter the impossibility of collecting values in depth of tissues. Finally, both ITPR and FMPE required lower doses than expected, and can be therefore reconsidered relative to their radiation risk.

  9. Uncertainties in Monte Carlo-based absorbed dose calculations for an experimental benchmark.

    PubMed

    Renner, F; Wulff, J; Kapsch, R-P; Zink, K

    2015-10-07

    There is a need to verify the accuracy of general purpose Monte Carlo codes like EGSnrc, which are commonly employed for investigations of dosimetric problems in radiation therapy. A number of experimental benchmarks have been published to compare calculated values of absorbed dose to experimentally determined values. However, there is a lack of absolute benchmarks, i.e. benchmarks without involved normalization which may cause some quantities to be cancelled. Therefore, at the Physikalisch-Technische Bundesanstalt a benchmark experiment was performed, which aimed at the absolute verification of radiation transport calculations for dosimetry in radiation therapy. A thimble-type ionization chamber in a solid phantom was irradiated by high-energy bremsstrahlung and the mean absorbed dose in the sensitive volume was measured per incident electron of the target. The characteristics of the accelerator and experimental setup were precisely determined and the results of a corresponding Monte Carlo simulation with EGSnrc are presented within this study. For a meaningful comparison, an analysis of the uncertainty of the Monte Carlo simulation is necessary. In this study uncertainties with regard to the simulation geometry, the radiation source, transport options of the Monte Carlo code and specific interaction cross sections are investigated, applying the general methodology of the Guide to the expression of uncertainty in measurement. Besides studying the general influence of changes in transport options of the EGSnrc code, uncertainties are analyzed by estimating the sensitivity coefficients of various input quantities in a first step. Secondly, standard uncertainties are assigned to each quantity which are known from the experiment, e.g. uncertainties for geometric dimensions. Data for more fundamental quantities such as photon cross sections and the I-value of electron stopping powers are taken from literature. The significant uncertainty contributions are identified as

  10. Development of a water calorimetry-based standard for absorbed dose to water in HDR {sup 192}Ir brachytherapy

    SciTech Connect

    Sarfehnia, Arman; Seuntjens, Jan

    2010-04-15

    Purpose: The aim of this article is to develop and evaluate a primary standard for HDR {sup 192}Ir brachytherapy based on 4 deg. C stagnant water calorimetry. Methods: The absolute absorbed dose to water was directly measured for several different Nucletron microSelectron {sup 192}Ir sources of air kerma strength ranging between 21 000 and 38 000 U and for source-to-detector separations ranging between 25 and 70 mm. The COMSOL MULTIPHYSICS software was used to accurately calculate the heat transport in a detailed model geometry. Through a coupling of the ''conduction and convection'' module with the ''Navier-Stokes incompressible fluid'' module in the software, both the conductive and convective effects were modeled. Results: A detailed uncertainty analysis resulted in an overall uncertainty in the absorbed dose of 1.90%(1{sigma}). However, this includes a 1.5% uncertainty associated with a nonlinear predrift correction which can be substantially reduced if sufficient time is provided for the system to come to a new equilibrium in between successive calorimetric runs, an opportunity not available to the authors in their clinical setting due to time constraints on the machine. An average normalized dose rate of 361{+-}7 {mu}Gy/(h U) at a source-to-detector separation of 55 mm was measured for the microSelectron {sup 192}Ir source based on water calorimetry. The measured absorbed dose per air kerma strength agreed to better than 0.8%(1{sigma}) with independent ionization chamber and EBT-1 Gafchromic film reference dosimetry as well as with the currently accepted AAPM TG-43 protocol measurements. Conclusions: This work paves the way toward a primary absorbed dose to water standard in {sup 192}Ir brachytherapy.

  11. Absorbed Dose and Dose Equivalent Calculations for Modeling Effective Dose

    NASA Technical Reports Server (NTRS)

    Welton, Andrew; Lee, Kerry

    2010-01-01

    While in orbit, Astronauts are exposed to a much higher dose of ionizing radiation than when on the ground. It is important to model how shielding designs on spacecraft reduce radiation effective dose pre-flight, and determine whether or not a danger to humans is presented. However, in order to calculate effective dose, dose equivalent calculations are needed. Dose equivalent takes into account an absorbed dose of radiation and the biological effectiveness of ionizing radiation. This is important in preventing long-term, stochastic radiation effects in humans spending time in space. Monte carlo simulations run with the particle transport code FLUKA, give absorbed and equivalent dose data for relevant shielding. The shielding geometry used in the dose calculations is a layered slab design, consisting of aluminum, polyethylene, and water. Water is used to simulate the soft tissues that compose the human body. The results obtained will provide information on how the shielding performs with many thicknesses of each material in the slab. This allows them to be directly applicable to modern spacecraft shielding geometries.

  12. Evaluation of absorbed doses in voxel-based and simplified models for small animals.

    PubMed

    Mohammadi, Akram; Kinase, Sakae; Saito, Kimiaki

    2012-07-01

    Internal dosimetry in non-human biota is desirable from the viewpoint of radiation protection of the environment. The International Commission on Radiological Protection (ICRP) proposed Reference Animals and Plants using simplified models, such as ellipsoids and spheres and calculated absorbed fractions (AFs) for whole bodies. In this study, photon and electron AFs in whole bodies of voxel-based rat and frog models have been calculated and compared with AFs in the reference models. It was found that the voxel-based and the reference frog (or rat) models can be consistent for the whole-body AFs within a discrepancy of 25%, as the source was uniformly distributed in the whole body. The specific absorbed fractions (SAFs) and S values were also evaluated in whole bodies and all organs of the voxel-based frog and rat models as the source was distributed in the whole body or skeleton. The results demonstrated that the whole-body SAFs reflect SAFs of all individual organs as the source was uniformly distributed per mass within the whole body by about 30% uncertainties with exceptions for body contour (up to -40%) for both electrons and photons due to enhanced radiation leakages, and for the skeleton for photons only (up to +185%) due to differences in the mass attenuation coefficients. For nuclides such as (90)Y and (90)Sr, which were concentrated in the skeleton, there were large differences between S values in the whole body and those in individual organs, however the whole-body S values for the reference models with the whole body as the source were remarkably similar to those for the voxel-based models with the skeleton as the source, within about 4 and 0.3%, respectively. It can be stated that whole-body SAFs or S values in simplified models without internal organs are not sufficient for accurate internal dosimetry because they do not reflect SAFs or S values of all individual organs as the source was not distributed uniformly in whole body. Thus, voxel-based models

  13. Development of modern approach to absorbed dose assessment in radionuclide therapy, based on Monte Carlo method simulation of patient scintigraphy

    NASA Astrophysics Data System (ADS)

    Lysak, Y. V.; Klimanov, V. A.; Narkevich, B. Ya

    2017-01-01

    One of the most difficult problems of modern radionuclide therapy (RNT) is control of the absorbed dose in pathological volume. This research presents new approach based on estimation of radiopharmaceutical (RP) accumulated activity value in tumor volume, based on planar scintigraphic images of the patient and calculated radiation transport using Monte Carlo method, including absorption and scattering in biological tissues of the patient, and elements of gamma camera itself. In our research, to obtain the data, we performed modeling scintigraphy of the vial with administered to the patient activity of RP in gamma camera, the vial was placed at the certain distance from the collimator, and the similar study was performed in identical geometry, with the same values of activity of radiopharmaceuticals in the pathological target in the body of the patient. For correct calculation results, adapted Fisher-Snyder human phantom was simulated in MCNP program. In the context of our technique, calculations were performed for different sizes of pathological targets and various tumors deeps inside patient’s body, using radiopharmaceuticals based on a mixed β-γ-radiating (131I, 177Lu), and clear β- emitting (89Sr, 90Y) therapeutic radionuclides. Presented method can be used for adequate implementing in clinical practice estimation of absorbed doses in the regions of interest on the basis of planar scintigraphy of the patient with sufficient accuracy.

  14. Evaluation of a deterministic grid-based Boltzmann solver (GBBS) for voxel-level absorbed dose calculations in nuclear medicine

    NASA Astrophysics Data System (ADS)

    Mikell, Justin; Cheenu Kappadath, S.; Wareing, Todd; Erwin, William D.; Titt, Uwe; Mourtada, Firas

    2016-06-01

    To evaluate the 3D Grid-based Boltzmann Solver (GBBS) code ATTILA ® for coupled electron and photon transport in the nuclear medicine energy regime for electron (beta, Auger and internal conversion electrons) and photon (gamma, x-ray) sources. Codes rewritten based on ATTILA are used clinically for both high-energy photon teletherapy and 192Ir sealed source brachytherapy; little information exists for using the GBBS to calculate voxel-level absorbed doses in nuclear medicine. We compared DOSXYZnrc Monte Carlo (MC) with published voxel-S-values to establish MC as truth. GBBS was investigated for mono-energetic 1.0, 0.1, and 0.01 MeV electron and photon sources as well as 131I and 90Y radionuclides. We investigated convergence of GBBS by analyzing different meshes ({{M}0},{{M}1},{{M}2} ), energy group structures ({{E}0},{{E}1},{{E}2} ) for each radionuclide component, angular quadrature orders (≤ft. {{S}4},{{S}8},{{S}16}\\right) , and scattering order expansions ({{P}0} -{{P}6} ); higher indices imply finer discretization. We compared GBBS to MC in (1) voxel-S-value geometry for soft tissue, lung, and bone, and (2) a source at the interface between combinations of lung, soft tissue, and bone. Excluding Auger and conversion electrons, MC agreed within  ≈5% of published source voxel absorbed doses. For the finest discretization, most GBBS absorbed doses in the source voxel changed by less than 1% compared to the next finest discretization along each phase space variable indicating sufficient convergence. For the finest discretization, agreement with MC in the source voxel ranged from  -3% to  -20% with larger differences at lower energies (-3% for 1 MeV electron in lung to  -20% for 0.01 MeV photon in bone); similar agreement was found for the interface geometries. Differences between GBBS and MC in the source voxel for 90Y and 131I were  -6%. The GBBS ATTILA was benchmarked against MC in the nuclear medicine regime. GBBS can be a viable

  15. Development and characterization of an interferometer for calorimeter-based absorbed dose to water measurements in a medical linear accelerator

    NASA Astrophysics Data System (ADS)

    Flores-Martinez, Everardo; Malin, Martha J.; DeWerd, Larry A.

    2016-11-01

    The quantity of relevance for external beam radiotherapy is absorbed dose to water (ADW). An interferometer was built, characterized, and tested to measure ADW within the dose range of interest for external beam radiotherapy using the temperature dependence of the refractive index of water. The interferometer was used to measure radiation-induced phase shifts of a laser beam passing through a (10 × 10 × 10) cm3 water-filled glass phantom, irradiated with a 6 MV photon beam from a medical linear accelerator. The field size was (7 × 7) cm2 and the dose was measured at a depth of 5 cm in the water phantom. The intensity of the interference pattern was measured with a photodiode and was used to calculate the time-dependent phase shift curve. The system was thermally insulated to achieve temperature drifts of less than 1.5 mK/min. Data were acquired 60 s before and after the irradiation. The radiation-induced phase shifts were calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. For 200, 300, and 400 monitor units, the measured doses were 1.6 ± 0.3, 2.6 ± 0.3, and 3.1 ± 0.3 Gy, respectively. Measurements agreed within the uncertainty with dose calculations performed with a treatment planning system. The estimated type-A, k = 1 uncertainty in the measured doses was 0.3 Gy which is an order of magnitude lower than previously published interferometer-based ADW measurements.

  16. Development and characterization of an interferometer for calorimeter-based absorbed dose to water measurements in a medical linear accelerator.

    PubMed

    Flores-Martinez, Everardo; Malin, Martha J; DeWerd, Larry A

    2016-11-01

    The quantity of relevance for external beam radiotherapy is absorbed dose to water (ADW). An interferometer was built, characterized, and tested to measure ADW within the dose range of interest for external beam radiotherapy using the temperature dependence of the refractive index of water. The interferometer was used to measure radiation-induced phase shifts of a laser beam passing through a (10 × 10 × 10) cm(3) water-filled glass phantom, irradiated with a 6 MV photon beam from a medical linear accelerator. The field size was (7 × 7) cm(2) and the dose was measured at a depth of 5 cm in the water phantom. The intensity of the interference pattern was measured with a photodiode and was used to calculate the time-dependent phase shift curve. The system was thermally insulated to achieve temperature drifts of less than 1.5 mK/min. Data were acquired 60 s before and after the irradiation. The radiation-induced phase shifts were calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. For 200, 300, and 400 monitor units, the measured doses were 1.6 ± 0.3, 2.6 ± 0.3, and 3.1 ± 0.3 Gy, respectively. Measurements agreed within the uncertainty with dose calculations performed with a treatment planning system. The estimated type-A, k = 1 uncertainty in the measured doses was 0.3 Gy which is an order of magnitude lower than previously published interferometer-based ADW measurements.

  17. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    NASA Technical Reports Server (NTRS)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  18. Method for Fast CT/SPECT-Based 3D Monte Carlo Absorbed Dose Computations in Internal Emitter Therapy

    PubMed Central

    Wilderman, S. J.; Dewaraja, Y. K.

    2010-01-01

    The DPM (Dose Planning Method) Monte Carlo electron and photon transport program, designed for fast computation of radiation absorbed dose in external beam radiotherapy, has been adapted to the calculation of absorbed dose in patient-specific internal emitter therapy. Because both its photon and electron transport mechanics algorithms have been optimized for fast computation in 3D voxelized geometries (in particular, those derived from CT scans), DPM is perfectly suited for performing patient-specific absorbed dose calculations in internal emitter therapy. In the updated version of DPM developed for the current work, the necessary inputs are a patient CT image, a registered SPECT image, and any number of registered masks defining regions of interest. DPM has been benchmarked for internal emitter therapy applications by comparing computed absorption fractions for a variety of organs using a Zubal phantom with reference results from the Medical Internal Radionuclide Dose (MIRD) Committee standards. In addition, the β decay source algorithm and the photon tracking algorithm of DPM have been further benchmarked by comparison to experimental data. This paper presents a description of the program, the results of the benchmark studies, and some sample computations using patient data from radioimmunotherapy studies using 131I. PMID:20305792

  19. Methods of calculating radiation absorbed dose.

    PubMed

    Wegst, A V

    1987-01-01

    The new tumoricidal radioactive agents being developed will require a careful estimate of radiation absorbed tumor and critical organ dose for each patient. Clinical methods will need to be developed using standard imaging or counting instruments to determine cumulated organ activities with tracer amounts before the therapeutic administration of the material. Standard MIRD dosimetry methods can then be applied.

  20. Direct MC conversion of absorbed dose to graphite to absorbed dose to water for 60Co radiation.

    PubMed

    Lye, J E; Butler, D J; Franich, R D; Harty, P D; Oliver, C P; Ramanathan, G; Webb, D V; Wright, T

    2013-06-01

    The ARPANSA calibration service for (60)Co gamma rays is based on a primary standard graphite calorimeter that measures absorbed dose to graphite. Measurements with the calorimeter are converted to the absorbed dose to water using the calculation of the ratio of the absorbed dose in the calorimeter to the absorbed dose in a water phantom. ARPANSA has recently changed the basis of this calculation from a photon fluence scaling method to a direct Monte Carlo (MC) calculation. The MC conversion uses an EGSnrc model of the cobalt source that has been validated against water tank and graphite phantom measurements, a step that is required to quantify uncertainties in the underlying interaction coefficients in the MC code. A comparison with the Bureau International des Poids et Mesures (BIPM) as part of the key comparison BIPM.RI(I)-K4 showed an agreement of 0.9973 (53).

  1. Absorbed doses from temporomandibular joint radiography

    SciTech Connect

    Brooks, S.L.; Lanzetta, M.L.

    1985-06-01

    Thermoluminescent dosimeters were used in a tissue-equivalent phantom to measure doses of radiation absorbed by various structures in the head when the temporomandibular joint was examined by four different radiographic techniques--the transcranial, transorbital, and sigmoid notch (Parma) projections and the lateral tomograph. The highest doses of radiation occurred at the point of entry for the x-ray beam, ranging from 112 mrad for the transorbital view to 990 mrad for the sigmoid notch view. Only the transorbital projection a radiation dose to the lens of the eye. Of the four techniques evaluated, the lateral tomograph produced the highest doses to the pituitary gland and the bone marrow, while the sigmoid notch radiograph produced the highest doses to the parotid gland.

  2. Absorbed dose from traversing spherically symmetric, Gaussian radioactive clouds

    SciTech Connect

    Thompson, J.M. ); Poston, J.W. . Dept. of Nuclear Engineering)

    1999-06-01

    If a large radioactive cloud is produced, sampling may require that an airplane traverse the cloud. A method to predict the absorbed dose to the aircrew from penetrating the radioactive cloud is needed. Dose rates throughout spherically symmetric Gaussian clouds of various sizes, and the absorbed doses from traversing the clouds, were calculated. Cloud size is a dominant parameter causing dose to vary by orders of magnitude for a given dose rate measured at some distance. A method to determine cloud size, based on dose rate readings at two or more distances from the cloud center, was developed. This method, however, failed to resolve the smallest cloud sizes from measurements made at 1,000 m to 2,000 m from the cloud center.

  3. Space radiation absorbed dose distribution in a human phantom

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Atwell, W.; Badavi, F. F.; Yang, T. C.; Cleghorn, T. F.

    2002-01-01

    The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose

  4. Space radiation absorbed dose distribution in a human phantom.

    PubMed

    Badhwar, G D; Atwell, W; Badavi, F F; Yang, T C; Cleghorn, T F

    2002-01-01

    The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose

  5. Ferroelectrics based absorbing layers

    NASA Astrophysics Data System (ADS)

    Hao, Jianping; Sadaune, Véronique; Burgnies, Ludovic; Lippens, Didier

    2014-07-01

    We show that ferroelectrics-based periodic structure made of BaSrTiO3 (BST) cubes, arrayed onto a metal plate with a thin dielectric spacer film exhibit a dramatic enhancement of absorbance with value close to unity. The enhancement is found around the Mie magnetic resonance of the Ferroelectrics cubes with the backside metal layer stopping any transmitted waves. It also involves quasi-perfect impedance matching resulting in reflection suppression via simultaneous magnetic and electrical activities. In addition, it was shown numerically the existence of a periodicity optimum, which is explained from surface waves analysis along with trade-off between the resonance damping and the intrinsic loss of ferroelectrics cubes. An experimental verification in a hollow waveguide configuration with a good comparison with full-wave numerical modelling is at last reported by measuring the scattering parameters of single and dual BST cubes schemes pointing out coupling effects for densely packed structures.

  6. Absorbed dose assessment of 177Lu-zoledronate and 177Lu-EDTMP for human based on biodistribution data in rats

    PubMed Central

    Yousefnia, Hassan; Zolghadri, Samaneh; Jalilian, Amir Reza

    2015-01-01

    Over the past few decades, several bone-seeking radiopharmaceuticals including various bisphosphonate ligands and β-emitting radionuclides have been developed for bone pain palliation. Recently, 177Lu was successfully labeled with zoledronic acid (177Lu-ZLD) as a new generation potential bisphosphonate and demonstrated significant accumulation in bone tissue. In this work, the absorbed dose to each organ of human for 177Lu-ZLD and 177Lu-ethylenediaminetetramethylene phosphonic acid (177Lu-EDTMP;as the only clinically bone pain palliation agent) was investigated based on biodistribution data in rats by medical internal radiation dosimetry (MIRD) method. 177Lu-ZLD and 177Lu-EDTMP were prepared in high radiochemical purity (>99%, instant thin layer chromatography (ITLC)) at the optimized condition. The biodistribution of the complexes demonstrated fast blood clearance and major accumulation in the bone tissue. The highest absorbed dose for both 177Lu-ZLD and 177Lu-EDTMP is observed in trabecular bone surface with 12.173 and 10.019 mSv/MBq, respectively. The results showed that 177Lu-ZLD has better characteristics compared to 177Lu-EDTMP and can be a good candidate for bone pain palliation. PMID:26170557

  7. Radiation absorbed dose estimates for 18F-BPA PET.

    PubMed

    Kono, Yuzuru; Kurihara, Hiroaki; Kawamoto, Hiroshi; Yasui, Naoko; Honda, Naoki; Igaki, Hiroshi; Itami, Jun

    2017-01-01

    Background Boron neutron capture therapy (BNCT) is a molecular radiation therapy approach based on the (10)B (n, α) (7)Li nuclear reaction in cancer cells. In BNCT, delivery of (10)B in the form of 4-borono-phenylalanine conjugated with fructose (BPA-fr) to the cancer cells is important. The PET tracer 4-borono-2-18F-fluoro-phenylalanine (FBPA) has been used to predict the accumulation of BPA-fr before BNCT. Purpose To determine the biodistribution and dosimetric parameters in 18F-BPA PET/CT studies. Material and Methods Human biokinetic data were obtained during clinical 18F-BPA PET studies between February and June 2015 at one institution. Nine consecutive patients were studied prospectively. The internal radiation dose was calculated on the basis of radioactivity data from blood, urine, and normal tissue of the heart, liver, spleen, kidney, and other parts of the body at each time point using OLINDA/EXM1.1 program. We compared our calculations with published 18F-FDG data. Results Adult patients (3 men, 3 women; age range, 28-68 years) had significantly smaller absorbed doses than pediatric patients (3 patients; age range, 5-12 years) ( P = 0.003). The mean effective dose was 57% lower in adult patients compared with pediatric patients. Mean effective doses for 18F-BPA were 25% lower than those for 18F-FDG presented in International Commission of Radiation Protection (ICRP) publication 106. Conclusion We found significant differences in organ absorbed doses for 18F-BPA against those for 18F-FDG presented in ICRP publication 106. Mean effective doses for 18F-BPA were smaller than those for 18F-FDG in the publication by 0.5-38% (mean difference, 25%).

  8. Development of a primary standard for absorbed dose from unsealed radionuclide solutions

    NASA Astrophysics Data System (ADS)

    Billas, I.; Shipley, D.; Galer, S.; Bass, G.; Sander, T.; Fenwick, A.; Smyth, V.

    2016-12-01

    Currently, the determination of the internal absorbed dose to tissue from an administered radionuclide solution relies on Monte Carlo (MC) calculations based on published nuclear decay data, such as emission probabilities and energies. In order to validate these methods with measurements, it is necessary to achieve the required traceability of the internal absorbed dose measurements of a radionuclide solution to a primary standard of absorbed dose. The purpose of this work was to develop a suitable primary standard. A comparison between measurements and calculations of absorbed dose allows the validation of the internal radiation dose assessment methods. The absorbed dose from an yttrium-90 chloride (90YCl) solution was measured with an extrapolation chamber. A phantom was developed at the National Physical Laboratory (NPL), the UK’s National Measurement Institute, to position the extrapolation chamber as closely as possible to the surface of the solution. The performance of the extrapolation chamber was characterised and a full uncertainty budget for the absorbed dose determination was obtained. Absorbed dose to air in the collecting volume of the chamber was converted to absorbed dose at the centre of the radionuclide solution by applying a MC calculated correction factor. This allowed a direct comparison of the analytically calculated and experimentally determined absorbed dose of an 90YCl solution. The relative standard uncertainty in the measurement of absorbed dose at the centre of an 90YCl solution with the extrapolation chamber was found to be 1.6% (k  =  1). The calculated 90Y absorbed doses from published medical internal radiation dose (MIRD) and radiation dose assessment resource (RADAR) data agreed with measurements to within 1.5% and 1.4%, respectively. This study has shown that it is feasible to use an extrapolation chamber for performing primary standard absorbed dose measurements of an unsealed radionuclide solution. Internal radiation

  9. USE OF A PHYSIOLOGICALLY-BASED PHARMACOKINETIC MODEL TO ESTIMATE ABSORBED CARBARYL DOSE IN CHILDREN AFTER TURF APPLICATION

    EPA Science Inventory

    A physiologically based pharmacokinetic (PBPK) model was developed to investigate exposure scenarios of children to carbaryl following turf application. Physiological, pharmacokinetic and pharmacodynamic parameters describing the fate and effects of carbaryl in rats were scaled ...

  10. Absorbed dose to water reference dosimetry using solid phantoms in the context of absorbed-dose protocols

    SciTech Connect

    Seuntjens, Jan; Olivares, Marina; Evans, Michael; Podgorsak, Ervin

    2005-09-15

    For reasons of phantom material reproducibility, the absorbed dose protocols of the American Association of Physicists in Medicine (AAPM) (TG-51) and the International Atomic Energy Agency (IAEA) (TRS-398) have made the use of liquid water as a phantom material for reference dosimetry mandatory. In this work we provide a formal framework for the measurement of absorbed dose to water using ionization chambers calibrated in terms of absorbed dose to water but irradiated in solid phantoms. Such a framework is useful when there is a desire to put dose measurements using solid phantoms on an absolute basis. Putting solid phantom measurements on an absolute basis has distinct advantages in verification measurements and quality assurance. We introduce a phantom dose conversion factor that converts a measurement made in a solid phantom and analyzed using an absorbed dose calibration protocol into absorbed dose to water under reference conditions. We provide techniques to measure and calculate the dose transfer from solid phantom to water. For an Exradin A12 ionization chamber, we measured and calculated the phantom dose conversion factor for six Solid Water{sup TM} phantoms and for a single Lucite phantom for photon energies between {sup 60}Co and 18 MV photons. For Solid Water{sup TM} of certified grade, the difference between measured and calculated factors varied between 0.0% and 0.7% with the average dose conversion factor being low by 0.4% compared with the calculation whereas for Lucite, the agreement was within 0.2% for the one phantom examined. The composition of commercial plastic phantoms and their homogeneity may not always be reproducible and consistent with assumed composition. By comparing measured and calculated phantom conversion factors, our work provides methods to verify the consistency of a given plastic for the purpose of clinical reference dosimetry.

  11. Evaluation of absorbed dose in Gadolinium neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Abdullaeva, Gayane; Djuraeva, Gulnara; Kim, Andrey; Koblik, Yuriy; Kulabdullaev, Gairatulla; Rakhmonov, Turdimukhammad; Saytjanov, Shavkat

    2015-02-01

    Gadolinium neutron capture therapy (GdNCT) is used for treatment of radioresistant malignant tumors. The absorbed dose in GdNCT can be divided into four primary dose components: thermal neutron, fast neutron, photon and natural gadolinium doses. The most significant is the dose created by natural gadolinium. The amount of gadolinium at the irradiated region is changeable and depends on the gadolinium delivery agent and on the structure of the location where the agent is injected. To de- fine the time dependence of the gadolinium concentration ρ(t) in the irradiated region the pharmacokinetics of gadolinium delivery agent (Magnevist) was studied at intratumoral injection in mice and intramuscular injection in rats. A polynomial approximation was applied to the experimental data and the influence of ρ(t) on the relative change of the absorbed dose of gadolinium was studied.

  12. Comparison between absorbed dose to water standards established by water calorimetry at the LNE-LNHB and by application of international air-kerma based protocols for kilovoltage medium energy x-rays.

    PubMed

    Perichon, N; Rapp, B; Denoziere, M; Daures, J; Ostrowsky, A; Bordy, J-M

    2013-05-07

    Nowadays, the absorbed dose to water for kilovoltage x-ray beams is determined from standards in terms of air-kerma by application of international dosimetry protocols. New standards in terms of absorbed dose to water has just been established for these beams at the LNE-LNHB, using water calorimetry, at a depth of 2 cm in water in accordance with protocols. The aim of this study is to compare these new standards in terms of absorbed dose to water, to the dose values calculated from the application of four international protocols based on air-kerma standards (IAEA TRS-277, AAPM TG-61, IPEMB and NCS-10). The acceleration potentials of the six beams studied are between 80 and 300 kV with half-value layers between 3.01 mm of aluminum and 3.40 mm of copper. A difference between the two methods smaller than 2.1% was reported. The standard uncertainty of water calorimetry being below 0.8%, and the one associated with the values from protocols being around 2.5%, the results are in good agreement. The calibration coefficients of some ionization chambers in terms of absorbed dose to water, established by application of calorimetry and air-kerma based dosimetry protocols, were also compared. The best agreement with the calibration coefficients established by water calorimetry was found for those established with the AAPM TG-61 protocol.

  13. Reduction of absorbed doses in radiography of the facial skeleton

    SciTech Connect

    Julin, P.; Kraepelien, T.

    1984-11-01

    Radiation absorbed doses from radiography of the paranasal sinuses and the facial skeleton were measured with thermoluminescent dosimeters (TLD) on a phantom head using high-sensitivity screens in an Orbix stand. The entrance doses to the skin of the head ranged from 0.31 to 2.9 mGy per exposure. The absorbed dose from a full series of sinus exposures averaged 0.33 mGy for the oral mucous membrane, 0.33 mGy for the maxillary sinus mucous membrane, 0.11 MgY for the parotid gland, 0.15 MgY for the submandibular gland, 0.61 mGy for the eye lens, and 0.75 mGy for the thyroid gland region. A leaded soft collar adapted to the thyroid region reduced the thyroid doses by more than one order of magnitude, but also reduced the image field.

  14. Absorbed dose assessment in newborns during x-ray examinations

    NASA Astrophysics Data System (ADS)

    Taipe, Patricia K.; Berrocal, Mariella J.; Carita, Raúl F.

    2012-02-01

    Often a newborn presents breathing problems during the early days of life, i.e. bronchopneumonia, wich are caused in most of cases, by aspirating a mixture of meconium and amniotic fluid. In these cases, it is necessary to make use of a radiograph, requested by the physician to reach a diagnosis. This paper seeks to evaluate the absorbed doses in neonates undergoing a radiograph. For this reason we try to simulate the real conditions in a X-ray room from Lima hospitals. With this finality we perform a simulation made according a questionnaire related to technical data of X-ray equipment, distance between the source and the neonate, and its position to be irradiated. The information obtained has been used to determine the absorbed dose by infants, using the MCNP code. Finally, the results are compared with reference values of international health agencies.

  15. A portable absorbed dose measuring instrument with gamma discrimination

    NASA Technical Reports Server (NTRS)

    Quam, W. M.; Wilde, W. I.

    1972-01-01

    The characteristics of an electronic instrument for measuring the radiation dose absorbed by tissues are presented. The detector is a sphere of tissue-equivalent plastic with a single wire located on a diameter of the sphere. The electronic circuits and method of operation of the detector are described. Advantages are the small size and easy portability plus ability to selectively measure neutron and gamma plus neutron events.

  16. Assessment of out-of-field absorbed dose and equivalent dose in proton fields

    SciTech Connect

    Clasie, Ben; Wroe, Andrew; Kooy, Hanne; Depauw, Nicolas; Flanz, Jay; Paganetti, Harald; Rosenfeld, Anatoly

    2010-01-15

    Purpose: In proton therapy, as in other forms of radiation therapy, scattered and secondary particles produce undesired dose outside the target volume that may increase the risk of radiation-induced secondary cancer and interact with electronic devices in the treatment room. The authors implement a Monte Carlo model of this dose deposited outside passively scattered fields and compare it to measurements, determine the out-of-field equivalent dose, and estimate the change in the dose if the same target volumes were treated with an active beam scanning technique. Methods: Measurements are done with a thimble ionization chamber and the Wellhofer MatriXX detector inside a Lucite phantom with field configurations based on the treatment of prostate cancer and medulloblastoma. The authors use a GEANT4 Monte Carlo simulation, demonstrated to agree well with measurements inside the primary field, to simulate fields delivered in the measurements. The partial contributions to the dose are separated in the simulation by particle type and origin. Results: The agreement between experiment and simulation in the out-of-field absorbed dose is within 30% at 10-20 cm from the field edge and 90% of the data agrees within 2 standard deviations. In passive scattering, the neutron contribution to the total dose dominates in the region downstream of the Bragg peak (65%-80% due to internally produced neutrons) and inside the phantom at distances more than 10-15 cm from the field edge. The equivalent doses using 10 for the neutron weighting factor at the entrance to the phantom and at 20 cm from the field edge are 2.2 and 2.6 mSv/Gy for the prostate cancer and cranial medulloblastoma fields, respectively. The equivalent dose at 15-20 cm from the field edge decreases with depth in passive scattering and increases with depth in active scanning. Therefore, active scanning has smaller out-of-field equivalent dose by factors of 30-45 in the entrance region and this factor decreases with depth

  17. Reduction of absorbed doses in radiography of the facial skeleton

    SciTech Connect

    Julin, P.; Kraepelien, T.

    1984-11-01

    Radiation absorbed doses from radiography of the paranasal sinuses and the facial skeleton were measured with thermoluminescent dosimeters (TLD) on a phantom head using high-sensitivity screens in an Orbix stand. The entrance doses to the skin of the head ranged from 0.31 to 2.9 mGy per exposure. The absorbed dose from a full series of sinus exposures averaged 0.33 mGy for the oral mucous membrane, 0.33 mGy for the maxillary sinus mucous membrane, 0.11 mGy for the parotid gland, 0.15 mGy for the submandibular gland, 0.61 mGy for the eye lens, and 0.75 mGy for the thyroid gland region. A leaded soft collar adapted to the thyroid region reduced the thyroid doses by more than one order of magnitude, but also reduced the image field. The mean energy imparted from a full series of paranasal sinus projections was 4.8 mJ and from a total series of the facial skeleton, 7.9 mJ.

  18. The absorbed dose to blood from blood-borne activity

    NASA Astrophysics Data System (ADS)

    Hänscheid, H.; Fernández, M.; Lassmann, M.

    2015-01-01

    The radiation absorbed dose to blood and organs from activity in the blood is relevant for nuclear medicine dosimetry and for research in biodosimetry. The present study provides coefficients for the average absorbed dose rates to the blood from blood-borne activity for radionuclides frequently used in targeted radiotherapy and in PET diagnostics. The results were deduced from published data for vessel radius-dependent dose rate coefficients and reasonable assumptions on the blood-volume distribution as a function of the vessel radius. Different parts of the circulatory system were analyzed separately. Vessel size information for heart chambers, aorta, vena cava, pulmonary artery, and capillaries was taken from published results of morphometric measurements. The remaining blood not contained in the mentioned vessels was assumed to reside in fractal-like vascular trees, the smallest branches of which are the arterioles or venules. The applied vessel size distribution is consistent with recommendations of the ICRP on the blood-volume distribution in the human. The resulting average absorbed dose rates to the blood per nuclear disintegration per milliliter (ml) of blood are (in 10-11 Gy·s-1·Bq-1·ml) Y-90: 5.58, I-131: 2.49, Lu-177: 1.72, Sm-153: 2.97, Tc-99m: 0.366, C-11: 4.56, F-18: 3.61, Ga-68: 5.94, I-124: 2.55. Photon radiation contributes 1.1-1.2·10-11 Gy·s-1·Bq-1·ml to the total dose rate for positron emitters but significantly less for the other nuclides. Blood self-absorption of the energy emitted by ß-particles in the whole blood ranges from 37% for Y-90 to 80% for Tc-99m. The correspondent values in vascular trees, which are important for the absorbed dose to organs, range from 30% for Y-90 to 82% for Tc-99m.

  19. SU-E-T-204: Comparison of Absorbed-Dose to Water in High-Energy Photon Beams Based On Addendum AAPM TG-51, IAEA TRS-398, and JSMP 12

    SciTech Connect

    Kinoshita, N; Kita, A; Yoshioka, C; Sasamoto, K; Nishimoto, Y; Adachi, T; Oguchi, H; Shioura, H; Kimura, H

    2015-06-15

    Purpose: Several clinical reference dosimetry protocols for absorbed-dose to water have recently been published: The American Association of Physicists in Medicine (AAPM) published an Addendum to the AAPM’s TG-51 (Addendum TG-51) in April 2014, and the Japan Society of Medical Physics (JSMP) published the Japan Society of Medical Physics 12 (JSMP12), a clinical reference dosimetry protocol, in September 2012. This investigation compared and evaluated the absorbed-dose to water of high-energy photon beams according to Addendum TG-51, International Atomic Energy Agency Technical Report Series No. 398 (TRS-398), and JSMP12. Methods: Differences in the respective beam quality conversion factors with Addendum TG-51, TRS-398, and JSMP12 were analyzed and the absorbed-dose to water using 6- and 10-MV photon beams was measured according to the protocols recommended in Addendum TG-51, TRS-398, and JSMP12. The measurements were conducted using two Farmer-type ionization chambers, Exradin A12 and PTW 30013. Results: The beam quality conversion factors for both the 6- and 10-MV photon beams with Addendum TG-51 were within 0.6%, in agreement with the beam quality conversion factors with TRS-398 and JSMP12. The Exradin A12 provided an absorbed-dose to water ratio from 1.003 to 1.006 with TRS-398 / Addendum TG-51 and from 1.004 to 1.005 with JSMP 12 / Addendum TG-51, whereas the PTW 30013 provided a ratio of 1.001 with TRS-398 / Addendum TG-51 and a range from 0.997 to 0.999 with JSMP 12 / Addendum TG-51. Conclusion: Despite differences in the beam quality conversion factor, no major differences were seen in the absorbed-dose to water with Addendum TG-51, TRS-398, and JSMP12. However, Addendum TG-51 provides the most recent data for beam quality conversion factors based on Monte Carlo simulation and greater detail for the measurement protocol. Therefore, the absorbed-dose to water measured with Addendum TG-51 is an estimate with less uncertainty.

  20. New absorbed dose measurement with cylindrical water phantoms for multidetector CT

    NASA Astrophysics Data System (ADS)

    Ohno, Takeshi; Araki, Fujio; Onizuka, Ryota; Hioki, Kazunari; Tomiyama, Yuuki; Yamashita, Yusuke

    2015-06-01

    The aim of this study was to develop new dosimetry with cylindrical water phantoms for multidetector computed tomography (MDCT). The ionization measurement was performed with a Farmer ionization chamber at the center and four peripheral points in the body-type and head-type cylindrical water phantoms. The ionization was converted to the absorbed dose using a 60Co absorbed-dose-to-water calibration factor and Monte Carlo (MC) -calculated correction factors. The correction factors were calculated from MDCT (Brilliance iCT, 64-slice, Philips Electronics) modeled with GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. The spectrum of incident x-ray beams and the configuration of a bowtie filter for MDCT were determined so that calculated photon intensity attenuation curves for aluminum (Al) and calculated off-center ratio (OCR) profiles in air coincided with those measured. The MC-calculated doses were calibrated by the absorbed dose measured at the center in both cylindrical water phantoms. Calculated doses were compared with measured doses at four peripheral points and the center in the phantom for various beam pitches and beam collimations. The calibration factors and the uncertainty of the absorbed dose determined using this method were also compared with those obtained by CTDIair (CT dose index in air). Calculated Al half-value layers and OCRs in air were within 0.3% and 3% agreement with the measured values, respectively. Calculated doses at four peripheral points and the centers for various beam pitches and beam collimations were within 5% and 2% agreement with measured values, respectively. The MC-calibration factors by our method were 44-50% lower than values by CTDIair due to the overbeaming effect. However, the calibration factors for CTDIair agreed within 5% with those of our method after correction for the overbeaming effect. Our method makes it possible to directly measure the absorbed dose for MDCT and is more robust and accurate than the

  1. Absorbed dose to the fetus during bone scintigraphy

    SciTech Connect

    Hedrick, W.R.; DiSimone, R.N.; Wolf, B.H.; Langer, A.

    1988-07-01

    The authors observed the uptake of radiopharmaceutical and calculated absorbed dose in fetuses of two patients who underwent bone scintigraphy with technetium-99m methylene diphosphonate. Dose estimates per administered activity were 17 mrad/mCi (4.6 microGy/MBq) for an 8-week-old fetus and 9.7 mrad/mCi (2.6 microGy/MBq) for an 18-week-old fetus. Neither fetus demonstrated radionuclide uptake above maternal background levels. The uterine activity showed rapid clearance, with an effective half-life of 12 minutes after reaching a maximum within 1 minute after injection. Major contribution to fetal dose comes from the presence of the radionuclide in the maternal bladder. The authors conclude that bone scintigraphy performed unknowingly in pregnant individuals presents negligible increased risk to the fetus.

  2. Tumor-Absorbed Dose Predicts Progression-Free Survival Following 131I-Tositumomab Radioimmunotherapy

    PubMed Central

    Dewaraja, Yuni K.; Schipper, Matthew J.; Shen, Jincheng; Smith, Lauren B.; Murgic, Jure; Savas, Hatice; Youssef, Ehab; Regan, Denise; Wilderman, Scott J.; Roberson, Peter L.; Kaminski, Mark S.; Avram, Anca M.

    2014-01-01

    The study aimed at identifying patient-specific dosimetric and nondosimetric factors predicting outcome of non-Hodgkin lymphoma patients after 131I-tositumomab radioimmunotherapy for potential use in treatment planning. Methods Tumor-absorbed dose measures were estimated for 130 tumors in 39 relapsed or refractory non-Hodgkin lymphoma patients by coupling SPECT/CT imaging with the Dose Planning Method (DPM) Monte Carlo code. Equivalent biologic effect was calculated to assess the biologic effects of nonuniform absorbed dose including the effects of the unlabeled antibody. Evaluated nondosimetric covariates included histology, presence of bulky disease, and prior treatment history. Tumor level outcome was based on volume shrinkage assessed on follow-up CT. Patient level outcome measures were overall response (OR), complete response (CR), and progression-free survival (PFS), determined from clinical assessments that included PET/CT. Results The estimated mean tumor-absorbed dose had a median value of 275 cGy (range, 94–711 cGy). A high correlation was observed between tracer-predicted and therapy-delivered mean tumor-absorbed doses (P < 0.001; r = 0.85). In univariate tumor-level analysis, tumor shrinkage correlated significantly with almost all of the evaluated dosimetric factors, including equivalent biologic effect. Regression analysis showed that OR, CR, and PFS were associated with the dosimetric factors and equivalent biologic effect. Both mean tumor-absorbed dose (P = 0.025) and equivalent biologic effect (P = 0.035) were significant predictors of PFS whereas none of the nondosimetric covariates were found to be statistically significant factors affecting PFS. The most important finding of the study was that in Kaplan–Meier curves stratified by mean dose, longer PFS was observed in patients receiving mean tumor-absorbed doses greater than 200 cGy than in those receiving 200 cGy or less (median PFS, 13.6 vs. 1.9 mo for the 2 dose groups; log-rank P < 0

  3. Radiation environments and absorbed dose estimations on manned space missions.

    PubMed

    Curtis, S B; Atwell, W; Beever, R; Hardy, A

    1986-01-01

    In order to make an assessment of radiation risk during manned missions in space, it is necessary first to have as accurate an estimation as possible of the radiation environment within the spacecraft to which the astronauts will be exposed. Then, with this knowledge and the inclusion of body self-shielding, estimations can be made of absorbed doses for various body organs (skin, eye, blood-forming organs, etc.). A review is presented of our present knowledge of the radiation environments and absorbed doses expected for several space mission scenarios selected for our development of the new radiation protection guidelines. The scenarios selected are a 90-day mission at an altitude (450 km) and orbital inclinations (28.5 degrees, 57 degrees and 90 degrees) appropriate for NASA's Space Station, a 15-day sortie to geosynchronous orbit and a 90-day lunar mission. All scenarios chosen yielded dose equivalents between five and ten rem to the blood forming organs if no large solar particle event were encountered. Such particle events could add considerable exposure particularly to the skin and eye for all scenarios except the one at 28.5 degrees orbital inclination.

  4. Absorbed dose measurements on LDEF and comparisons with predictions.

    PubMed

    Benton, E V; Frank, A L; Benton, E R; Armstrong, T W; Colborn, B L

    1996-11-01

    The radiation environment on LDEF was monitored by cumulative absorbed dose measurements made with TLDs at different locations and shielding depths. The TLDs were included in four experiments: A0015(a) Biostack, P0004 Seeds in Space and P0006 Linear Energy Transfer Spectrum Measurements at the trailing edge (west side) of the satellite; M0004 Fiber Optics Data Link at the leading edge (east side); and A0015(b) Biostack at the Earth side. The shielding depths varied between 0.48 and 15.4 g/cm2, Al equivalent. Both the directional dependence of trapped protons incident on the satellite and the shielding thickness were reflected in absorbed dose values. The trapped proton anisotropy was measured by TLDs at the east and west sides of LDEF. At the east side doses ranged from 2.10 to 2.58 Gy under shielding of 2.90 to 1.37 g/cm2 (M0004) while on the west side doses ranged from 2.66 to 6.48 Gy under shielding of 15.4 to 0.48 g/cm2 (P0006). The west side doses were more than a factor of two higher, where the vertical shielding thicknesses to space were equal. Other west side doses of 3.04 to 4.49 Gy under shielding of 11.7 to 3.85 g/cm2 (A0015(a)) and 2.91 to 6.64 Gy under shielding of 11.1 to 0.48 g/cm2 (P0004) generally agreed with the P0006 results. The Earth side doses of 2.41 to 3.93 Gy under shielding of 10.0 to 1.66 g cm2 (A0015(b)) were intermediate between the east side and west side doses. Calculations utilizing a model of trapped proton spectra were performed by Watts et al. (1993) and comparisons of dose measurement and calculations may be found in a companion paper (Armstrong et al., 1996).

  5. Absorbed dose measurements on LDEF and comparisons with predictions

    NASA Technical Reports Server (NTRS)

    Benton, E. V.; Frank, A. L.; Benton, E. R.; Armstrong, T. W.; Colborn, B. L.

    1996-01-01

    The radiation environment on LDEF was monitored by cumulative absorbed dose measurements made with TLDs at different locations and shielding depths. The TLDs were included in four experiments: A0015(a) Biostack, P0004 Seeds in Space and P0006 Linear Energy Transfer Spectrum Measurements at the trailing edge (west side) of the satellite; M0004 Fiber Optics Data Link at the leading edge (east side); and A0015(b) Biostack at the Earth side. The shielding depths varied between 0.48 and 15.4 g/cm2, Al equivalent. Both the directional dependence of trapped protons incident on the satellite and the shielding thickness were reflected in absorbed dose values. The trapped proton anisotropy was measured by TLDs at the east and west sides of LDEF. At the east side doses ranged from 2.10 to 2.58 Gy under shielding of 2.90 to 1.37 g/cm2 (M0004) while on the west side doses ranged from 2.66 to 6.48 Gy under shielding of 15.4 to 0.48 g/cm2 (P0006). The west side doses were more than a factor of two higher, where the vertical shielding thicknesses to space were equal. Other west side doses of 3.04 to 4.49 Gy under shielding of 11.7 to 3.85 g/cm2 (A0015(a)) and 2.91 to 6.64 Gy under shielding of 11.1 to 0.48 g/cm2 (P0004) generally agreed with the P0006 results. The Earth side doses of 2.41 to 3.93 Gy under shielding of 10.0 to 1.66 g cm2 (A0015(b)) were intermediate between the east side and west side doses. Calculations utilizing a model of trapped proton spectra were performed by Watts et al. (1993) and comparisons of dose measurement and calculations may be found in a companion paper (Armstrong et al., 1996).

  6. Air kerma and absorbed dose standards for reference dosimetry in brachytherapy

    PubMed Central

    2014-01-01

    This article reviews recent developments in primary standards for the calibration of brachytherapy sources, with an emphasis on the currently most common photon-emitting radionuclides. The introduction discusses the need for reference dosimetry in brachytherapy in general. The following section focuses on the three main quantities, i.e. reference air kerma rate, air kerma strength and absorbed dose rate to water, which are currently used for the specification of brachytherapy photon sources and which can be realized with primary standards from first principles. An overview of different air kerma and absorbed dose standards, which have been independently developed by various national metrology institutes over the past two decades, is given in the next two sections. Other dosimetry techniques for brachytherapy will also be discussed. The review closes with an outlook on a possible transition from air kerma to absorbed dose to water-based calibrations for brachytherapy sources in the future. PMID:24814696

  7. Study of Fricke-gel dosimeter calibration for attaining precise measurements of the absorbed dose

    SciTech Connect

    Liosi, Giulia Maria; Benedini, Sara; Giacobbo, Francesca; Mariani, Mario; Gambarini, Grazia; Artuso, Emanuele; Gargano, Marco; Ludwig, Nicola; Carrara, Mauro; Pignoli, Emanuele

    2015-07-01

    A method has been studied for attaining, with good precision, absolute measurements of the spatial distribution of the absorbed dose by means of the Fricke gelatin Xylenol Orange dosimetric system. With this aim, the dose response to subsequent irradiations was analyzed. In fact, the proposed modality is based on a pre-irradiation of each single dosimeter in a uniform field with a known dose, in order to extrapolate a calibration image for a subsequent non-uniform irradiation with an un-known dose to be measured. (authors)

  8. Absorbed dose dependence of the correction factors for ionization chamber cable irradiation effects.

    PubMed

    Campos, L L; Caldas, L V

    1991-03-01

    A simple method was developed, for possible use by hospital physicists, to evaluate the irradiation effects on cables and connectors during large-radiation-field dosimetry with ionization chambers and to determine correction factors for the used system or geometry. This method was based on the absorbed dose dependence of the correction factor.

  9. Depth distribution of absorbed dose on the external surface of Cosmos 1887 biosatellite

    SciTech Connect

    Watts, J.W. Jr.; Parnell, T.A.; Akatov, Yu.A.; Dudkin, V.E.; Kovalev, E.E.; Benton, E.V.; Frank, A.L. |

    1995-03-01

    Significant absorbed dose levels exceeding 1.0 Gy day(exp {minus}1) have been measured on the external surface of the Cosmos 1887 biosatellite as functions of depth in stacks of thin thermoluminescent detectors (TLD`s) made in U.S.S.R. and U.S.A. The dose was found to decrease rapidly with increasing absorber thickness, thereby indicating the presence of intensive fluxes of low-energy particles. Comparison between the U.S.S.R. and U.S.A. results and calculations based on the Vette Model environment are in satisfactory agreement. The major contribution to the dose under thin shielding thickness is shown to be from electrons. The fraction of the dose due to protons and heavier charged particles increases with shielding thickness.

  10. Depth distribution of absorbed dose on the external surface of Cosmos 1887 biosatellite

    NASA Technical Reports Server (NTRS)

    Watts, J. W., Jr.; Parnell, T. A.; Akatov, Yu. A.; Dudkin, V. E.; Kovalev, E. E.; Benton, E. V.; Frank, A. L.

    1995-01-01

    Significant absorbed dose levels exceeding 1.0 Gy day(exp -1) have been measured on the external surface of the Cosmos 1887 biosatellite as functions of depth in stacks of thin thermoluminescent detectors (TLD's) made in U.S.S.R. and U.S.A. The dose was found to decrease rapidly with increasing absorber thickness, thereby indicating the presence of intensive fluxes of low-energy particles. Comparison between the U.S.S.R. and U.S.A. results and calculations based on the Vette Model environment are in satisfactory agreement. The major contribution to the dose under thin shielding thickness is shown to be from electrons. The fraction of the dose due to protons and heavier charged particles increases with shielding thickness.

  11. Diamond detector in absorbed dose measurements in high-energy linear accelerator photon and electron beams.

    PubMed

    Ravichandran, Ramamoorthy; Binukumar, John Pichy; Al Amri, Iqbal; Davis, Cheriyathmanjiyil Antony

    2016-03-08

    Diamond detectors (DD) are preferred in small field dosimetry of radiation beams because of small dose profile penumbras, better spatial resolution, and tissue-equivalent properties. We investigated a commercially available 'microdiamond' detector in realizing absorbed dose from first principles. A microdiamond detector, type TM 60019 with tandem electrometer is used to measure absorbed doses in water, nylon, and PMMA phantoms. With sensitive volume 0.004 mm3, radius 1.1mm, thickness 1 x10(-3) mm, the nominal response is 1 nC/Gy. It is assumed that the diamond detector could collect total electric charge (nC) developed during irradiation at 0 V bias. We found that dose rate effect is less than 0.7% for changing dose rate by 500 MU/min. The reproducibility in obtaining readings with diamond detector is found to be ± 0.17% (1 SD) (n = 11). The measured absorbed doses for 6 MV and 15 MV photons arrived at using mass energy absorption coefficients and stop-ping power ratios compared well with Nd, water calibrated ion chamber measured absorbed doses within 3% in water, PMMA, and nylon media. The calibration factor obtained for diamond detector confirmed response variation is due to sensitivity due to difference in manufacturing process. For electron beams, we had to apply ratio of electron densities of water to carbon. Our results qualify diamond dosimeter as a transfer standard, based on long-term stability and reproducibility. Based on micro-dimensions, we recommend these detectors for pretreatment dose verifications in small field irradiations like stereotactic treatments with image guidance.

  12. Calculation of the absorbed dose and dose equivalent induced by medium energy neutrons and protons and comparison with experiment

    NASA Technical Reports Server (NTRS)

    Armstrong, T. W.; Bishop, B. L.

    1972-01-01

    Monte Carlo calculations have been carried out to determine the absorbed dose and dose equivalent for 592-MeV protons incident on a cylindrical phantom and for neutrons from 580-MeV proton-Be collisions incident on a semi-infinite phantom. For both configurations, the calculated depth dependence of the absorbed dose is in good agreement with experimental data.

  13. Assessment of the accuracy of an MCNPX-based Monte Carlo simulation model for predicting three-dimensional absorbed dose distributions.

    PubMed

    Titt, U; Sahoo, N; Ding, X; Zheng, Y; Newhauser, W D; Zhu, X R; Polf, J C; Gillin, M T; Mohan, R

    2008-08-21

    In recent years, the Monte Carlo method has been used in a large number of research studies in radiation therapy. For applications such as treatment planning, it is essential to validate the dosimetric accuracy of the Monte Carlo simulations in heterogeneous media. The AAPM Report no 105 addresses issues concerning clinical implementation of Monte Carlo based treatment planning for photon and electron beams, however for proton-therapy planning, such guidance is not yet available. Here we present the results of our validation of the Monte Carlo model of the double scattering system used at our Proton Therapy Center in Houston. In this study, we compared Monte Carlo simulated depth doses and lateral profiles to measured data for a magnitude of beam parameters. We varied simulated proton energies and widths of the spread-out Bragg peaks, and compared them to measurements obtained during the commissioning phase of the Proton Therapy Center in Houston. Of 191 simulated data sets, 189 agreed with measured data sets to within 3% of the maximum dose difference and within 3 mm of the maximum range or penumbra size difference. The two simulated data sets that did not agree with the measured data sets were in the distal falloff of the measured dose distribution, where large dose gradients potentially produce large differences on the basis of minute changes in the beam steering. Hence, the Monte Carlo models of medium- and large-size double scattering proton-therapy nozzles were valid for proton beams in the 100 MeV-250 MeV interval.

  14. The IPEM code of practice for electron dosimetry for radiotherapy beams of initial energy from 4 to 25 MeV based on an absorbed dose to water calibration

    NASA Astrophysics Data System (ADS)

    Thwaites (Chair), IPEM Working Party: D. I.; Du Sautoy, A. R.; Jordan, T.; McEwen, M. R.; Nisbet, A.; Nahum, A. E.; Pitchford, W. G.

    2003-09-01

    This report contains the recommendations of the Electron Dosimetry Working Party of the UK Institute of Physics and Engineering in Medicine (IPEM). The recommendations consist of a code of practice for electron dosimetry for radiotherapy beams of initial energy from 4 to 25 MeV. The code is based on the absorbed dose to water calibration service for electron beams provided by the UK standards laboratory, the National Physical Laboratory (NPL). This supplies direct ND,w calibration factors, traceable to a calorimetric primary standard, at specified reference depths over a range of electron energies up to approximately 20 MeV. Electron beam quality is specified in terms of R50,D, the depth in water along the beam central axis at which the dose is 50% of the maximum. The reference depth for any given beam at the NPL for chamber calibration and also for measurements for calibration of clinical beams is 0.6R50,D - 0.1 cm in water. Designated chambers are graphite-walled Farmer-type cylindrical chambers and the NACP- and Roos-type parallel-plate chambers. The practical code provides methods to determine the absorbed dose to water under reference conditions and also guidance on methods to transfer this dose to non-reference points and to other irradiation conditions. It also gives procedures and data for extending up to higher energies above the range where direct calibration factors are currently available. The practical procedures are supplemented by comprehensive appendices giving discussion of the background to the formalism and the sources and values of any data required. The electron dosimetry code improves consistency with the similar UK approach to megavoltage photon dosimetry, in use since 1990. It provides reduced uncertainties, approaching 1% standard uncertainty in optimal conditions, and a simpler formalism than previous air kerma calibration based recommendations for electron dosimetry.

  15. Pain and Mean Absorbed Dose to the Pubic Bone After Radiotherapy Among Gynecological Cancer Survivors

    SciTech Connect

    Waldenstroem, Ann-Charlotte; Olsson, Caroline; Wilderaeng, Ulrica; Dunberger, Gail; Lind, Helena; Al-Abany, Massoud; Palm, Asa; Avall-Lundqvist, Elisabeth; Johansson, Karl-Axel; Steineck, Gunnar

    2011-07-15

    Purpose: To analyze the relationship between mean absorbed dose to the pubic bone after pelvic radiotherapy for gynecological cancer and occurrence of pubic bone pain among long-term survivors. Methods and Materials: In an unselected, population-based study, we identified 823 long-term gynecological cancer survivors treated with pelvic radiotherapy during 1991-2003. For comparison, we used a non-radiation-treated control population of 478 matched women from the Swedish Population Register. Pain, intensity of pain, and functional impairment due to pain in the pubic bone were assessed with a study-specific postal questionnaire. Results: We analyzed data from 650 survivors (participation rate 79%) with median follow-up of 6.3 years (range, 2.3-15.0 years) along with 344 control women (participation rate, 72 %). Ten percent of the survivors were treated with radiotherapy; ninety percent with surgery plus radiotherapy. Brachytherapy was added in 81%. Complete treatment records were recovered for 538/650 survivors, with dose distribution data including dose-volume histograms over the pubic bone. Pubic bone pain was reported by 73 survivors (11%); 59/517 (11%) had been exposed to mean absorbed external beam doses <52.5 Gy to the pubic bone and 5/12 (42%) to mean absorbed external beam doses {>=}52.5 Gy. Thirty-three survivors reported pain affecting sleep, a 13-fold increased prevalence compared with control women. Forty-nine survivors reported functional impairment measured as pain walking indoors, a 10-fold increased prevalence. Conclusions: Mean absorbed external beam dose above 52.5 Gy to the pubic bone increases the occurrence of pain in the pubic bone and may affect daily life of long-term survivors treated with radiotherapy for gynecological cancer.

  16. Graves' disease radioiodine-therapy: Choosing target absorbed doses for therapy planning

    SciTech Connect

    Willegaignon, J. Sapienza, M. T.; Coura-Filho, G. B.; Buchpiguel, C. A.; Watanabe, T.; Traino, A. C.

    2014-01-15

    {sup ~} was determined by the integration of measured {sup 131}I activity in the thyroid gland and based on T{sub eff}, respectively. No statistically significant relationship was found between therapeutic response and patients’ age, administered {sup 131}I activity (MBq), 24-h thyroid {sup 131}I uptake (%) or T{sub eff} (p ≥ 0.064); nonetheless, a good relationship was found between the therapeutic response and m{sub th} (p ≤ 0.035). Conclusions: According to the results of this study, the most effective thyroid absorbed dose to be targeted in GD therapy should not be based on a fixed dose but rather should be individualized based on the patient'sm{sub th} and A{sup ~}. To achieve a therapeutic success (i.e., durable euthyroidism or hypothyroidism) rate of at least 95%, a thyroid absorbed dose of 200 or 330 Gy is required depending on the methodology used for estimating m{sub th} and A{sup ~}.

  17. A method for a short-term forecast of the absorbed dose accumulation dynamics on the international space station based on radiation monitoring system data

    NASA Astrophysics Data System (ADS)

    Lishnevskii, A. E.; Benghin, V. V.

    2014-12-01

    Many papers are devoted to the prediction of radiation conditions on board of a spacecraft (Pichkhadze et al., 2004; Khamidullina et al., 2008; 2012), and a number of software systems for corresponding calculations have been developed: the US information system CREME96 (https://creme.isde.vander-bilt.edu/); European SPENVIS (http://www.spenvis.oma.be/intro.php); Russian SEREIS (Kuznetsov et al., 2001; Model' kosmosa, 2007) and COSRAD (http://cosrad.sinp.msu.ru/manual.html; Kuznetsov et al., 2011) based on the models of the radiation environment in near-Earth space (Bashkirov et al., 1998; Nymmik, 2004; Model' kosmosa, 2007; Kuznetsov et al., 2011). In this paper we propose a simple calculation algorithm of short-term (for a few days) forecasting of dynamics of the radiation dose on the International Space Station (ISS) in radiation environment undisturbed by solar proton events. This algorithm does not use radiation environment models and detailed ballistic calculations, while it uses data of the onboard radiation monitoring system (RMS) and empirical relations, obtained for ISS orbital motion.

  18. Absorbed Dose Determination Using Experimental and Analytical Predictions of X-Ray Spectra

    NASA Technical Reports Server (NTRS)

    Edwards, D. L.; Carruth, Ralph (Technical Monitor)

    2001-01-01

    Electron beam welding in a vacuum is a technology that NASA is investigating as a joining technique for manufacture of space structures. This investigation characterizes the x-ray environment due to operation of an in-vacuum electron beam welding tool and provides recommendations for adequate shielding for astronauts performing the in-vacuum electron beam welding. NASA, in a joint venture with the Russian Space Agency, was scheduled to perform a series of welding in space experiments on board the U.S. Space Shuttle. This series of experiments was named the international space welding experiment (ISWE). The hardware associated with the ISWE was leased to NASA by the Paton Welding Institute (PWI) in Ukraine for ground-based welding experiments in preparation for flight. Two ground tests were scheduled, using the ISWE electron beam welding tool, to characterize the radiation exposure to an astronaut during the operation of the ISWE. These radiation exposure tests used thermoluminescence dosimeters (TLD's) shielded with material currently used by astronauts during extravehicular activities to measure the radiation dose. The TLD's were exposed to x-ray radiation generated by operation of the ISWE in-vacuum electron beam welding tool. This investigation was the first known application of TLD's to measure absorbed dose from x rays of energy less than 10 keV. The ISWE hardware was returned to Ukraine before the issue of adequate shielding for the astronauts was completely verified. Therefore, alternate experimental and analytical methods were developed to measure and predict the x-ray spectral and intensity distribution generated by ISWE electron beam impact with metal. These x-ray spectra were normalized to an equivalent ISWE exposure, then used to calculate the absorbed radiation dose to astronauts. These absorbed dose values were compared to TLD measurements obtained during actual operation of the ISWE in-vacuum electron beam welding tool. The calculated absorbed dose

  19. The Fricke dosimeter as an absorbed dose to water primary standard for Ir-192 brachytherapy.

    PubMed

    El Gamal, Islam; Cojocaru, Claudiu; Mainegra-Hing, Ernesto; McEwen, Malcolm

    2015-06-07

    The aim of this project was to develop an absorbed dose to water primary standard for Ir-192 brachytherapy based on the Fricke dosimeter. To achieve this within the framework of the existing TG-43 protocol, a determination of the absorbed dose to water at the reference position, D(r0,θ0), was undertaken. Prior to this investigation, the radiation chemical yield of the ferric ions (G-value) at the Ir-192 equivalent photon energy (0.380 MeV) was established by interpolating between G-values obtained for Co-60 and 250 kV x-rays.An irradiation geometry was developed with a cylindrical holder to contain the Fricke solution and allow irradiations in a water phantom to be conducted using a standard Nucletron microSelectron V2 HDR Ir-192 afterloader. Once the geometry and holder were optimized, the dose obtained with the Fricke system was compared to the standard method used in North America, based on air-kerma strength.Initial investigations focused on reproducible positioning of the ring-shaped holder for the Fricke solution with respect to the Ir-192 source and obtaining an acceptable type A uncertainty in the optical density measurements required to yield the absorbed dose. Source positioning was found to be reproducible to better than 0.3 mm, and a careful cleaning and control procedure reduced the variation in optical density reading due to contamination of the Fricke solution by the PMMA holder. It was found that fewer than 10 irradiations were required to yield a type A standard uncertainty of less than 0.5%.Correction factors to take account of the non-water components of the geometry and the volume averaging effect of the Fricke solution volume were obtained from Monte Carlo calculations. A sensitivity analysis showed that the dependence on the input data used (e.g. interaction cross-sections) was small with a type B uncertainty for these corrections estimated to be 0.2%.The combined standard uncertainty in the determination of absorbed dose to water at

  20. Absorbed dose rate in air in metropolitan Tokyo before the Fukushima Daiichi Nuclear Power Plant accident.

    PubMed

    Inoue, K; Hosoda, M; Fukushi, M; Furukawa, M; Tokonami, S

    2015-11-01

    The monitoring of absorbed dose rate in air has been carried out continually at various locations in metropolitan Tokyo after the accident of the Fukushima Daiichi Nuclear Power Plant. While the data obtained before the accident are needed to more accurately assess the effects of radionuclide contamination from the accident, detailed data for metropolitan Tokyo obtained before the accident have not been reported. A car-borne survey of the absorbed dose rate in air in metropolitan Tokyo was carried out during August to September 2003. The average absorbed dose rate in air in metropolitan Tokyo was 49±6 nGy h(-1). The absorbed dose rate in air in western Tokyo was higher compared with that in central Tokyo. Here, if the absorbed dose rate indoors in Tokyo is equivalent to that outdoors, the annual effective dose would be calculated as 0.32 mSv y(-1).

  1. Uncertainty analysis for absorbed dose from a brain receptor imaging agent

    SciTech Connect

    Aydogan, B.; Miller, L.F.; Sparks, R.B.; Stubbs, J.B.

    1999-01-01

    Absorbed dose estimates are known to contain uncertainties. A recent literature search indicates that prior to this study no rigorous investigation of uncertainty associated with absorbed dose has been undertaken. A method of uncertainty analysis for absorbed dose calculations has been developed and implemented for the brain receptor imaging agent {sup 123}I-IPT. The two major sources of uncertainty considered were the uncertainty associated with the determination of residence time and that associated with the determination of the S values. There are many sources of uncertainty in the determination of the S values, but only the inter-patient organ mass variation was considered in this work. The absorbed dose uncertainties were determined for lung, liver, heart and brain. Ninety-five percent confidence intervals of the organ absorbed dose distributions for each patient and for a seven-patient population group were determined by the ``Latin Hypercube Sampling`` method. For an individual patient, the upper bound of the 95% confidence interval of the absorbed dose was found to be about 2.5 times larger than the estimated mean absorbed dose. For the seven-patient population the upper bound of the 95% confidence interval of the absorbed dose distribution was around 45% more than the estimated population mean. For example, the 95% confidence interval of the population liver dose distribution was found to be between 1.49E+0.7 Gy/MBq and 4.65E+07 Gy/MBq with a mean of 2.52E+07 Gy/MBq. This study concluded that patients in a population receiving {sup 123}I-IPT could receive absorbed doses as much as twice as large as the standard estimated absorbed dose due to these uncertainties.

  2. SADDE (Scaled Absorbed Dose Distribution Evaluator): A code to generate input for VARSKIN

    SciTech Connect

    Reece, W.D.; Miller, S.D.; Durham, J.S.

    1989-01-01

    The VARSKIN computer code has been limited to the isotopes for which the scaled absorbed dose distributions were provided by the Medical Internal Radiation Dose (MIRD) Committee or to data that could be interpolated from isotopes that had similar spectra. This document describes the methodology to calculate the scaled absorbed dose distribution data for any isotope (including emissions by the daughter isotopes) and its implementation by a computer code called SADDE (Scaled Absorbed Dose Distribution Evaluator). The SADDE source code is provided along with input examples and verification calculations. 10 refs., 4 figs.

  3. Perfect terahertz absorber using fishnet based metafilm

    SciTech Connect

    Azad, Abul Kalam; Shchegolkov, Dmitry Yu; Chen, Houtong; Taylor, Antoinette; Smirnova, E I; O' Hara, John F

    2009-01-01

    We present a perfect terahertz (THz) absorber working for a broad-angle of incidence. The two fold symmetry of rectangular fishnet structure allows either complete absorption or mirror like reflection depending on the polarization of incident the THz beam. Metamaterials enable the ability to control the electromagnetic wave in a unique fashion by designing the permittivity or permeability of composite materials with desired values. Although the initial idea of metamaterials was to obtain a negative index medium, however, the evolution of metamaterials (MMs) offers a variety of practically applicable devices for controlling electromagnetic wave such as tunable filters, modulators, phase shifters, compact antenna, absorbers, etc. Terahertz regime, a crucial domain of the electromagnetic wave, is suffering from the scarcity of the efficient devices and might take the advantage of metamaterials. Here, we demonstrate design, fabrication, and characterization of a terahertz absorber based on a simple fishnet metallic film separated from a ground mirror plane by a dielectric spacer. Such absorbers are in particular important for bolometric terahertz detectors, high sensitivity imaging, and terahertz anechoic chambers. Recently, split-ring-resonators (SRR) have been employed for metamaterial-based absorbers at microwave and THz frequencies. The experimental demonstration reveals that such absorbers have absorptivity close to unity at resonance frequencies. However, the downside of these designs is that they all employ resonators of rather complicated shape with many fine parts and so they are not easy to fabricate and are sensitive to distortions.

  4. A Feasibility Study of Fricke Dosimetry as an Absorbed Dose to Water Standard for 192Ir HDR Sources

    PubMed Central

    deAlmeida, Carlos Eduardo; Ochoa, Ricardo; de Lima, Marilene Coelho; David, Mariano Gazineu; Pires, Evandro Jesus; Peixoto, José Guilherme; Salata, Camila; Bernal, Mario Antônio

    2014-01-01

    High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brachytherapy sources is presented in this study. The main goal of this paper is to demonstrate the potential usefulness of the Fricke dosimetry technique for the standardization of the quantity absorbed dose to water for 192Ir sources. A molded, double-walled, spherical vessel for water containing the Fricke solution was constructed based on the Fricke system. The authors measured the absorbed dose to water and compared it with the doses calculated using the AAPM TG-43 report. The overall combined uncertainty associated with the measurements using Fricke dosimetry was 1.4% for k = 1, which is better than the uncertainties reported in previous studies. These results are promising; hence, the use of Fricke dosimetry to measure the absorbed dose to water as a standard for HDR 192Ir may be possible in the future. PMID:25521914

  5. The estimation of absorbed dose rates for non-human biota : an extended inter-comparison.

    SciTech Connect

    Batlle, J. V. I.; Beaugelin-Seiller, K.; Beresford, N. A.; Copplestone, D.; Horyna, J.; Hosseini, A.; Johansen, M.; Kamboj, S.; Keum, D.-K.; Kurosawa, N.; Newsome, L.; Olyslaegers, G.; Vandenhove, H.; Ryufuku, S.; Lynch, S. V.; Wood, M. D.; Yu, C.

    2011-05-01

    An exercise to compare 10 approaches for the calculation of unweighted whole-body absorbed dose rates was conducted for 74 radionuclides and five of the ICRP's Reference Animals and Plants, or RAPs (duck, frog, flatfish egg, rat and elongated earthworm), selected for this exercise to cover a range of body sizes, dimensions and exposure scenarios. Results were analysed using a non-parametric method requiring no specific hypotheses about the statistical distribution of data. The obtained unweighted absorbed dose rates for internal exposure compare well between the different approaches, with 70% of the results falling within a range of variation of {+-}20%. The variation is greater for external exposure, although 90% of the estimates are within an order of magnitude of one another. There are some discernible patterns where specific models over- or under-predicted. These are explained based on the methodological differences including number of daughter products included in the calculation of dose rate for a parent nuclide; source-target geometry; databases for discrete energy and yield of radionuclides; rounding errors in integration algorithms; and intrinsic differences in calculation methods. For certain radionuclides, these factors combine to generate systematic variations between approaches. Overall, the technique chosen to interpret the data enabled methodological differences in dosimetry calculations to be quantified and compared, allowing the identification of common issues between different approaches and providing greater assurance on the fundamental dose conversion coefficient approaches used in available models for assessing radiological effects to biota.

  6. A geochemical assessment of terrestrial gamma-ray absorbed dose rates.

    PubMed

    Wollenberg, H A; Smith, A R

    1990-02-01

    A survey of the geochemical literature and unpublished data has resulted in the classification of the concentrations of the naturally occurring radioelements U, Th, and K by their associated rock types. A data base of over 2500 entries has been compiled, permitting calculation of terrestrial gamma-ray absorbed dose rates. The general lithology of terrains may be distinguished by their radioelement ratios, relative abundances, and total gamma radioactivities. The gamma-ray absorbed dose rates in air above igneous rocks generally vary with their silica contents, and with the exception of shale, sedimentary rocks have lower K:U and K:Th ratios than most igneous rocks. The appreciable difference between the overall mean terrestrial gamma-ray dose rate for rock of the continental surface (approximately 7 X 10(-8) Gy h-1) and the mean dose rate from field measurements over soil (approximately 5 X 10(-8) Gy h-1) is explained by the substantial differences between radioelement concentrations of soil and rock, differences that may vary markedly with rock type.

  7. Estimates of absorbed dose in different organs in children treated with radium for skin hemangiomas

    SciTech Connect

    Lundell, M.

    1994-12-01

    Between 1930 and 1959, more than 10,000 infants were treated at Radiumhemmet, Stockholm, with radium ({sup 226}Ra) needles and/or tubes for hemangioma of the skin. Absorbed dose to the brain, eye lenses, parotid glands, thyroid gland, breast enlarge, lungs, stomach, intestine, ovaries, testicles and bone marrow were calculated for each individual. The mean absorbed dose to the different organs ranged from 0.06 to 0.48 Gy. The highest absorbed dose was given to the breast (maximum 47.7 Gy). There was a wide dose range for each organ which was due mainly to differences in the distance between the applicator and the organ. The absorbed dose to all organs decreased on average by 32% during the study period. This was due to a 25% decrease in the treatment time and a change in the distribution of the treatment sites. 17 refs., 4 figs., 4 tabs.

  8. Photon extremity absorbed dose and kerma conversion coefficients for calibration geometries.

    PubMed

    Veinot, K G; Hertel, N E

    2007-02-01

    Absorbed dose and dose equivalent conversion coefficients are routinely used in personnel dosimetry programs. These conversion coefficients can be applied to particle fluences or to measured air kerma values to determine appropriate operational monitoring quantities such as the ambient dose equivalent or personal dose equivalent for a specific geometry. For personnel directly handling materials, the absorbed dose to the extremities is of concern. This work presents photon conversion coefficients for two extremity calibration geometries using finger and wrist/arm phantoms described in HPS N13.32. These conversion coefficients have been calculated as a function of photon energy in terms of the kerma and the absorbed dose using Monte Carlo techniques and the calibration geometries specified in HPS N13.32. Additionally, kerma and absorbed dose conversion coefficients for commonly used x-ray spectra and calibration source fields are presented. The kerma values calculated in this work for the x-ray spectra and calibration sources compare well to those listed in HPS N13.32. The absorbed dose values, however, differ significantly for higher energy photons because charged particle equilibrium conditions have not been satisfied for the shallow depth. Thus, the air-kerma-to-dose and exposure-to-dose conversion coefficients for Cs and Co listed in HPS N13.32 overestimate the absorbed dose to the extremities. Applying the conversion coefficients listed in HPS N13.32 for Cs, for example, would result in an overestimate of absorbed dose of 62% for the finger phantom and 55% for the wrist phantom.

  9. The changes in optical absorbance of ZrO2 thin film with the rise of the absorbed dose

    NASA Astrophysics Data System (ADS)

    Abayli, D.; Baydogan, N.

    2016-03-01

    In this study, zirconium oxide (ZrO2) thin film samples prepared by sol-gel method were irradiated using Co-60 radioisotope as gamma source. Then, it was investigated the ionizing effect on optical properties of ZrO2 thin film samples with the rise of the absorbed dose. The changes in the optical absorbance of ZrO2 thin films were determined by using optical transmittance and the reflectance measurements in the range between 190 - 1100 nm obtained from PG Instruments T80 UV-Vis spectrophotometer.

  10. Metamaterial Absorber Based Multifunctional Sensor Application

    NASA Astrophysics Data System (ADS)

    Ozer, Z.; Mamedov, A. M.; Ozbay, E.

    2017-02-01

    In this study metamaterial based (MA) absorber sensor, integrated with an X-band waveguide, is numerically and experimentally suggested for important application including pressure, density sensing and marble type detecting applications based on rectangular split ring resonator, sensor layer and absorber layer that measures of changing in the dielectric constant and/or the thickness of a sensor layer. Changing of physical, chemical or biological parameters in the sensor layer can be detected by measuring the resonant frequency shifting of metamaterial absorber based sensor. Suggested MA based absorber sensor can be used for medical, biological, agricultural and chemical detecting applications in microwave frequency band. We compare the simulation and experimentally obtained results from the fabricated sample which are good agreement. Simulation results show that the proposed structure can detect the changing of the refractive indexes of different materials via special resonance frequencies, thus it could be said that the MA-based sensors have high sensitivity. Additionally due to the simple and tiny structures it could be adapted to other electronic devices in different sizes.

  11. Radiation-induced biomarkers for the detection and assessment of absorbed radiation doses

    PubMed Central

    Rana, Sudha; Kumar, Raj; Sultana, Sarwat; Sharma, Rakesh Kumar

    2010-01-01

    Radiation incident involving living organisms is an uncommon but a very serious situation. The first step in medical management including triage is high-throughput assessment of the radiation dose received. Radiation exposure levels can be assessed from viability of cells, cellular organelles such as chromosome and different intermediate metabolites. Oxidative damages by ionizing radiation result in carcinogenesis, lowering of the immune response and, ultimately, damage to the hematopoietic system, gastrointestinal system and central nervous system. Biodosimetry is based on the measurement of the radiation-induced changes, which can correlate them with the absorbed dose. Radiation biomarkers such as chromosome aberration are most widely used. Serum enzymes such as serum amylase and diamine oxidase are the most promising biodosimeters. The level of gene expression and protein are also good biomarkers of radiation. PMID:21829314

  12. Space Radiation Absorbed Dose Distribution in a Human Phantom Torso

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Yang, T.; Atwell, W.

    2000-01-01

    The flight of a human phantom torso with head that containing active dosimeters at 5 organ sites and 1400 TLDs distributed in 34 1" thick sections is described. Experimental dose rates and quality factors are compared with calculations for shielding distributions at the sites using the Computerized Anatomical Male (CAM) model. The measurements were complemented with those obtained from other instruments. These results have provided the most comprehensive data set to map the dose distribution inside a human and to assess the accuracy of radiation transport models and astronaut radiation risk.

  13. Absorbed dose simulations in near-surface regions using high dose rate Iridium-192 sources applied for brachytherapy

    NASA Astrophysics Data System (ADS)

    Moura, E. S.; Zeituni, C. A.; Sakuraba, R. K.; Gonçalves, V. D.; Cruz, J. C.; Júnior, D. K.; Souza, C. D.; Rostelato, M. E. C. M.

    2014-02-01

    Brachytherapy treatment with Iridium-192 high dose rate (HDR) sources is widely used for various tumours and it could be developed in many anatomic regions. Iridium-192 sources are inserted inside or close to the region that will be treated. Usually, the treatment is performed in prostate, gynaecological, lung, breast and oral cavity regions for a better clinical dose coverage compared with other techniques, such as, high energy photons and Cobalt-60 machines. This work will evaluate absorbed dose distributions in near-surface regions around Ir-192 HDR sources. Near-surface dose measurements are a complex task, due to the contribution of beta particles in the near-surface regions. These dose distributions should be useful for non-tumour treatments, such as keloids, and other non-intracavitary technique. For the absorbed dose distribution simulations the Monte Carlo code PENELOPE with the general code penEasy was used. Ir-192 source geometry and a Polymethylmethacrylate (PMMA) tube, for beta particles shield were modelled to yield the percentage depth dose (PDD) on a cubic water phantom. Absorbed dose simulations were realized at the central axis to yield the Ir-192 dose fall-off along central axis. The results showed that more than 99.2% of the absorbed doses (relative to the surface) are deposited in 5 cm depth but with slower rate at higher distances. Near-surface treatments with Ir-192 HDR sources yields achievable measurements and with proper clinical technique and accessories should apply as an alternative for treatment of lesions where only beta sources were used.

  14. Graphite calorimetry for absorbed dose measurements in heavy-ion beams

    NASA Astrophysics Data System (ADS)

    Sakama, M.; Kanai, T.; Fukumura, A.

    In order to sophisticate the radiotherapy high accuracy knowledge of the absorbed dose delivered to the patient is essential The main methods of absolute dosimetry are indicated as follows a Dosimetry by ion chamber b Fricke dosimetry and c Calorimetry The calorimetry is most direct method of dosimetry due to direct measurement of energy deposit in principle and no requirement of information of radiation fields for the calibration Many countries tend to adopt the calorimetry to determine the standard absorbed dose to water and become to be capable of deciding the absorbed dose in precision of about 0 6 for photon and electron beams Despite the recent progress of particle therapy the parameters such as w-value and stopping power ratio for ionization chambers in the particles is not obtained accurately Therefore that causes uncertainty in determination of the absolute dose For this reason we developed a graphite calorimeter to obtain high precision absorbed dose and reduce the uncertainty for various beams When the absorbed dose of 1 Gy is irradiated to the sensitive volume the temperature rise is about 1 4 milliKelvins The performance require the resolution of plus or minus 7 micro Kelvins to measure it in precision of plus or minus 0 5 The stability within several micro Kelvins per minute is necessary to obtain measurable background The miniature glass bead thermistors were embedded in the sensitive volume to perform active control of temperature The resistance change of these thermistors is approximately 0 68 Ohms and 488 micro Ohms at

  15. A Comparison of Model Calculation and Measurement of Absorbed Dose for Proton Irradiation. Chapter 5

    NASA Technical Reports Server (NTRS)

    Zapp, N.; Semones, E.; Saganti, P.; Cucinotta, F.

    2003-01-01

    With the increase in the amount of time spent EVA that is necessary to complete the construction and subsequent maintenance of ISS, it will become increasingly important for ground support personnel to accurately characterize the radiation exposures incurred by EVA crewmembers. Since exposure measurements cannot be taken within the organs of interest, it is necessary to estimate these exposures by calculation. To validate the methods and tools used to develop these estimates, it is necessary to model experiments performed in a controlled environment. This work is such an effort. A human phantom was outfitted with detector equipment and then placed in American EMU and Orlan-M EVA space suits. The suited phantom was irradiated at the LLUPTF with proton beams of known energies. Absorbed dose measurements were made by the spaceflight operational dosimetrist from JSC at multiple sites in the skin, eye, brain, stomach, and small intestine locations in the phantom. These exposures are then modeled using the BRYNTRN radiation transport code developed at the NASA Langley Research Center, and the CAM (computerized anatomical male) human geometry model of Billings and Yucker. Comparisons of absorbed dose calculations with measurements show excellent agreement. This suggests that there is reason to be confident in the ability of both the transport code and the human body model to estimate proton exposure in ground-based laboratory experiments.

  16. Absorbed dose calculations to blood and blood vessels for internally deposited radionuclides

    SciTech Connect

    Akabani, G.; Poston, J.W. Sr. )

    1991-05-01

    At present, absorbed dose calculations for radionuclides in the human circulatory system used relatively simple models and are restricted in their applications. To determine absorbed doses to the blood and to the surface of the blood vessel wall, EGS4 Monte Carlo calculations were performed. Absorbed doses were calculated for the blood and the blood vessel wall (lumen) for different blood vessels sizes. The radionuclides chosen for this study were those commonly used in nuclear medicine. No penetration of the radionuclide into the blood vessel was assumed nor was cross fire between the vessel assumed. The results are useful in assessing the dose to blood and blood vessel walls for different nuclear medicine procedures.

  17. Absorbed dose calculations to blood and blood vessels for internally deposited radionuclides

    SciTech Connect

    Akabani, G. ); Poston, J.W. . Dept. of Nuclear Engineering)

    1991-05-01

    At present, absorbed dose calculations for radionuclides in the human circulatory system used relatively simple models and are restricted in their applications. To determine absorbed doses to the blood and to the surface of the blood vessel wall, EGS4 Monte Carlo calculations were performed. Absorbed doses were calculated for the blood and the blood vessel wall (lumen) for different blood vessels sizes. The radionuclides chosen for this study were those commonly used in nuclear medicine. No diffusion of the radionuclide into the blood vessel was assumed nor cross fire between vessel was assumed. Results are useful in assessing the dose in blood and blood vessel walls for different nuclear medicine procedures. 6 refs., 6 figs., 5 tabs.

  18. Assessment of organ absorbed doses and estimation of effective doses from pediatric anthropomorphic phantom measurements for multi-detector row CT with and without automatic exposure control.

    PubMed

    Brisse, Hervé J; Robilliard, Magalie; Savignoni, Alexia; Pierrat, Noelle; Gaboriaud, Geneviève; De Rycke, Yann; Neuenschwander, Sylvia; Aubert, Bernard; Rosenwald, Jean-Claude

    2009-10-01

    This study was designed to measure organ absorbed doses from multi-detector row computed tomography (MDCT) on pediatric anthropomorphic phantoms, calculate the corresponding effective doses, and assess the influence of automatic exposure control (AEC) in terms of organ dose variations. Four anthropomorphic phantoms (phantoms represent the equivalent of a newborn, 1-, 5-, and 10-y-old child) were scanned with a four-channel MDCT coupled with a z-axis-based AEC system. Two CT torso protocols were compared: a first protocol without AEC and constant tube current-time product and a second protocol with AEC using age-adjusted noise indices. Organ absorbed doses were monitored by thermoluminescent dosimeters (LiF: Mg, Cu, P). Effective doses were calculated according to the tissue weighting factors of the International Commission on Radiological Protection (). For fixed mA acquisitions, organ doses normalized to the volume CT dose index in a 16-cm head phantom (CTDIvol16) ranged from 0.6 to 1.5 and effective doses ranged from 8.4 to 13.5 mSv. For the newborn-equivalent phantom, the AEC-modulated scan showed almost no significant dose variation compared to the fixed mA scan. For the 1-, 5- and 10-y equivalent phantoms, the use of AEC induced a significant dose decrease on chest organs (ranging from 61 to 31% for thyroid, 37 to 21% for lung, 34 to 17% for esophagus, and 39 to 10% for breast). However, AEC also induced a significant dose increase (ranging from 28 to 48% for salivary glands, 22 to 51% for bladder, and 24 to 70% for ovaries) related to the high density of skull base and pelvic bones. These dose increases should be considered before using AEC as a dose optimization tool in children.

  19. Absorbed dose-to-water protocol applied to synchrotron-generated x-rays at very high dose rates

    NASA Astrophysics Data System (ADS)

    Fournier, P.; Crosbie, J. C.; Cornelius, I.; Berkvens, P.; Donzelli, M.; Clavel, A. H.; Rosenfeld, A. B.; Petasecca, M.; Lerch, M. L. F.; Bräuer-Krisch, E.

    2016-07-01

    Microbeam radiation therapy (MRT) is a new radiation treatment modality in the pre-clinical stage of development at the ID17 Biomedical Beamline of the European synchrotron radiation facility (ESRF) in Grenoble, France. MRT exploits the dose volume effect that is made possible through the spatial fractionation of the high dose rate synchrotron-generated x-ray beam into an array of microbeams. As an important step towards the development of a dosimetry protocol for MRT, we have applied the International Atomic Energy Agency’s TRS 398 absorbed dose-to-water protocol to the synchrotron x-ray beam in the case of the broad beam irradiation geometry (i.e. prior to spatial fractionation into microbeams). The very high dose rates observed here mean the ion recombination correction factor, k s , is the most challenging to quantify of all the necessary corrections to apply for ionization chamber based absolute dosimetry. In the course of this study, we have developed a new method, the so called ‘current ramping’ method, to determine k s for the specific irradiation and filtering conditions typically utilized throughout the development of MRT. Using the new approach we deduced an ion recombination correction factor of 1.047 for the maximum ESRF storage ring current (200 mA) under typical beam spectral filtering conditions in MRT. MRT trials are currently underway with veterinary patients at the ESRF that require additional filtering, and we have estimated a correction factor of 1.025 for these filtration conditions for the same ESRF storage ring current. The protocol described herein provides reference dosimetry data for the associated Treatment Planning System utilized in the current veterinary trials and anticipated future human clinical trials.

  20. Absorbed XFEL Dose in the Components of the LCLS X-Ray Optics

    SciTech Connect

    Hau-Riege, Stefan

    2010-12-03

    There is great concern that the short, intense XFEL pulse of the LCLS will damage the optics that will be placed into the beam. We have analyzed the extent of the problem by considering the anticipated materials and position of the optical components in the beam path, calculated the absorbed dose as a function of photon energy, and compared these doses with the expected doses required (i) to observe rapid degradation due to thermal fatigue, (ii) to reach the melting temperature, or (iii) to actually melt the material. We list the materials that are anticipated to be placed into the Linac Coherent Light Source (LCLS) x-ray free electron laser (XFEL) beam line, their positions, and the absorbed dose, and compare this dose with anticipated damage thresholds.

  1. Absorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131I

    SciTech Connect

    Vega-Carrillo, Hector Rene; Manzanares-Acuna, Eduardo; Hernandez-Davila, Victor Martin; Arcos-Pichardo, Areli; Barquero, Raquel; Iniguez, M. Pilar

    2006-09-08

    The use of 131I is widely used in diagnostic and treatment of patients. If the patient is pregnant the 131I presence in the thyroid it becomes a source of constant exposition to other organs and the fetus. In this study the absorbed dose in the uterus of a 3 months pregnant woman with 131I in her thyroid gland has been calculated. The dose was determined using Monte Carlo methods in which a detailed model of the woman has been developed. The dose was also calculated using a simple procedure that was refined including the photons' attenuation in the woman organs and body. To verify these results an experiment was carried out using a neck phantom with 131I. Comparing the results it was found that the simple calculation tend to overestimate the absorbed dose, by doing the corrections due to body and organs photon attenuation the dose is 0.14 times the Monte Carlo estimation.

  2. Absorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131I

    NASA Astrophysics Data System (ADS)

    Vega-Carrillo, Héctor René; Manzanares-Acuña, Eduardo; Hernández-Dávila, Víctor Martín; Arcos-Pichardo, Areli; Barquero, Raquel; Iñiguez, M. Pilar

    2006-09-01

    The use of 131I is widely used in diagnostic and treatment of patients. If the patient is pregnant the 131I presence in the thyroid it becomes a source of constant exposition to other organs and the fetus. In this study the absorbed dose in the uterus of a 3 months pregnant woman with 131I in her thyroid gland has been calculated. The dose was determined using Monte Carlo methods in which a detailed model of the woman has been developed. The dose was also calculated using a simple procedure that was refined including the photons' attenuation in the woman organs and body. To verify these results an experiment was carried out using a neck phantom with 131I. Comparing the results it was found that the simple calculation tend to overestimate the absorbed dose, by doing the corrections due to body and organs photon attenuation the dose is 0.14 times the Monte Carlo estimation.

  3. The experimental determination of C lambda using an absorbed dose calorimeter.

    PubMed

    Williams, P C

    1980-01-01

    The absorbed dose conversion factors, C lambda, were introduced, by Greene and Massey, as an interim measure until a primary standard for high energy photon dosimetry could be established. The theoretical basis of these factors has been discussed extensively and a more rigorous definition has emerged. Experiments have been carried out to determine the values of C lambda, for a Tufnol walled, Baldwin-Farmer ionisation chamber over a range of energies from cobalt-60 to 12 MV. The experimental results, based on measurements with a calorimeter, presented here support the more rigorous definition but it is shown that the values obtained depend, to a small extent, on the assumptions made about the detailed construction of the ionisation chamber for which C lambda is measured.

  4. An estimate by two methods of thyroid absorbed doses due to BRAVO fallout in several northern Marshall Islands

    SciTech Connect

    Musolino, S.V.; Hull, A.P.; Greenhouse, N.A.

    1997-10-01

    Estimates of the thyroid absorbed doses due to fallout originating from the 1 March 1954 BRAVO thermonuclear test on Bikini Atoll have been made for several inhabited locations in the Northern Marshall Islands. Rongelap, Utirik, Rongerik and Ailinginae Atolls were also inhabited on 1 March 1954, where retrospective thyroid absorbed doses have previously been reconstructed. Current estimates are based primarily on external exposure data, which were recorded shortly after each nuclear test in the Castle Series, and secondarily on soil concentrations of {sup 137}Cs in samples collected in 1978 and 1988, along with aerial monitoring done in 1978. External exposures and {sup 137}Cs Soil concentrations were representative of the atmospheric transport and deposition patterns of the entire Castle Series tests and show that the BRAVO test was the major contributor to fallout exposure during the Castle series and other test series which were carried out in the Marshall Islands. These data have been used as surrogates for fission product radioiodines and telluriums in order to estimate the range of thyroid absorbed doses that may have occurred throughout the Marshall Islands. Dosimetry based on these two sets of estimates agreed within a factor of 4 at the locations where BRAVO was the dominant contributor to the total exposure and deposition. Both methods indicate that thyroid absorbed doses in the range of 1 Gy (100 rad) may have been incurred in some of the northern locations, whereas the doses at southern locations did not significantly exceed levels comparable to those from worldwide fallout. The results of these estimates indicate that a systematic medical survey for thyroid disease should be conducted, and that a more definitive dose reconstruction should be made for all the populated atolls and islands in the Northern Marshall Islands beyond Rongelap, Utirik, Rongerik and Ailinginae, which were significantly contaminated by BRAVO fallout. 30 refs., 2 figs., 10 tabs.

  5. An estimate by two methods of thyroid absorbed doses due to BRAVO fallout in several Northern Marshall Islands.

    PubMed

    Musolino, S V; Greenhouse, N A; Hull, A P

    1997-10-01

    Estimates of the thyroid absorbed doses due to fallout originating from the 1 March 1954 BRAVO thermonuclear test on Bikini Atoll have been made for several inhabited locations in the Northern Marshall Islands. Rongelap, Utirik, Rongerik and Ailinginae Atolls were also inhabited on 1 March 1954, where retrospective thyroid absorbed doses have previously been reconstructed. The current estimates are based primarily on external exposure data, which were recorded shortly after each nuclear test in the Castle Series, and secondarily on soil concentrations of 137Cs in samples collected in 1978 and 1988, along with aerial monitoring done in 1978. The external exposures and 137Cs soil concentrations were representative of the atmospheric transport and deposition patterns of the entire Castle Series tests and show that the BRAVO test was the major contributor to fallout exposure during the Castle series and other test series which were carried out in the Marshall Islands. These data have been used as surrogates for fission product radioiodines and telluriums in order to estimate the range of thyroid absorbed doses that may have occurred throughout the Marshall Islands. Dosimetry based on these two sets of estimates agreed within a factor of 4 at the locations where BRAVO was the dominant contributor to the total exposure and deposition. Both methods indicate that thyroid absorbed doses in the range of 1 Gy (100 rad) may have been incurred in some of the northern locations, whereas the doses at southern locations did not significantly exceed levels comparable to those from worldwide fallout. The results of these estimates indicate that a systematic medical survey for thyroid disease should be conducted, and that a more definitive dose reconstruction should be made for all the populated atolls and islands in the Northern Marshall Islands beyond Rongelap, Utirik, Rongerik and Ailinginae, which were significantly contaminated by BRAVO fallout.

  6. Radiation absorbed dose estimates for oxygen-15 radiopharmaceuticals (H2( V)O, C VO, O VO) in newborn infants

    SciTech Connect

    Powers, W.J.; Stabin, M.; Howse, D.; Eichling, J.O.; Herscovitch, P.

    1988-12-01

    In preparation for measurement of regional cerebral oxygen metabolism by positron emission tomography, radiation absorbed dose estimates for 19 internal organs, blood, and total body were calculated for newborn infants following bolus intravenous administration of H2( V)O and brief inhalation of C VO and O VO. Cumulated activity for each radiopharmaceutical was calculated from a compartmental model based on the known biologic behavior of the compound. Values for mean absorbed dose/unit cumulated activity (S) for internal organs and total body were based on a newborn phantom. S was separately calculated for blood. Total radiopharmaceutical absorbed dose estimates necessary to measure cerebral oxygen metabolism in a 3.51-kg infant based on 0.7 mCi/kg H2( V)O and 1 mCi/kg C VO and O VO were determined to be 1.6 rad to the lung (maximum organ dose), 0.28 rad to the marrow, 0.46 rad to the gonads, and 0.22 rad to total body. These values are similar to those for current clinical nuclear medicine procedures employing /sup 99m/Tc in newborn infants.

  7. Measurement of absorbed dose during the phantom torso experiment on the International Space Station

    NASA Astrophysics Data System (ADS)

    Semones, E.; Gibbons, F.; Golightly, M.; Weyland, M.; Johnson, A.; Smith, G.; Shelfer, T.; Zapp, N.

    The Phantom Torso Experiment (PTE) was flown on the International Space Station (ISS) during Increment 2 (April-August 2001). The experiment was located in the US Lab module Human Research Facility (HRF) rack. The objective of the passive dosimetry portion of the experiment was to measure spatial distributions of absorbed dose in the 34, 1 inch sections of a modified RandoTM phantom. In each section of the phantom, thermoluminescent detectors (TLDs) were placed at various locations (depths) to provide the spatial measurement. TLDs were also located at several radiosensitive organ locations (brain, thyroid, heart/lung, stomach and colon) and two locations on the surface (skin). Active silicon detectors were also placed at these organ locations to provide time resolved results of the absorbed dose rates. Using these detectors, it is possible to separate the trapped and galactic cosmic ray components of the absorbed dose. The TLD results of the spatial and organ dose measurements will be presented and comparisons of the TLD and silicon detector organ absorbed doses will be made.

  8. Improved estimates of the radiation absorbed dose to the urinary bladder wall.

    PubMed

    Andersson, Martin; Minarik, David; Johansson, Lennart; Mattsson, Sören; Leide-Svegborn, Sigrid

    2014-05-07

    Specific absorbed fractions (SAFs) have been calculated as a function of the content in the urinary bladder in order to allow more realistic calculations of the absorbed dose to the bladder wall. The SAFs were calculated using the urinary bladder anatomy from the ICRP male and female adult reference computational phantoms. The urinary bladder and its content were approximated by a sphere with a wall of constant mass, where the thickness of the wall depended on the amount of urine in the bladder. SAFs were calculated for males and females with 17 different urinary bladder volumes from 10 to 800 mL, using the Monte Carlo computer program MCNP5, at 25 energies of mono-energetic photons and electrons ranging from 10 KeV to 10 MeV. The decay was assumed to be homogeneously distributed in the urinary bladder content and the urinary bladder wall, and the mean absorbed dose to the urinary bladder wall was calculated. The Monte Carlo simulations were validated against measurements made with thermoluminescent dosimeters. The SAFs obtained for a urine volume of 200 mL were compared to the values calculated for the urinary bladder wall using the adult reference computational phantoms. The mean absorbed dose to the urinary wall from (18)F-FDG was found to be 77 µGy/MBq formales and 86 µGy/MBq for females, while for (99m)Tc-DTPA the mean absorbed doses were 80 µGy/MBq for males and 86 µGy/MBq for females. Compared to calculations using a constant value of the SAF from the adult reference computational phantoms, the mean absorbed doses to the bladder wall were 60% higher for (18)F-FDG and 30% higher for (99m)Tc-DTPA using the new SAFs.

  9. A robust method for determining the absorbed dose to water in a phantom for low-energy photon radiation

    NASA Astrophysics Data System (ADS)

    Schneider, T.

    2011-06-01

    The application of more and more low-energy photon radiation in brachytherapy—either in the form of low-dose-rate radioactive seeds such as Pd-103 or I-125 or in the form of miniature x-ray tubes—has induced greater interest in determining the absorbed dose to water in water in this energy range. As it seems to be hardly feasible to measure the absorbed dose with calorimetric methods in this low energy range, ionometric methods are the preferred choice. However, the determination of the absorbed dose to water in water by ionometric methods is difficult in this energy range. With decreasing energy, the relative uncertainty of the photon cross sections increases and as the mass energy transfer coefficients show a steep gradient, the spectra of the radiation field must be known precisely. In this work two ionometric methods to determine the absorbed dose to water are evaluated with respect to their sensitivity to the uncertainties of the spectra and of the atomic database. The first is the measurement of the air kerma free in air and the application of an MC-based conversion factor to the absorbed dose to water. The second is the determination of the absorbed dose to water by means of an extrapolation chamber as an integral part of a phantom. In the complementing MC-calculations, two assortments of spectra each of which is based on a separate unfolding procedure were used as well as two kinds of databases: the standard PEGS and the recently implemented NIST database of EGSnrc. Experimental results were obtained by using a parallel-plate graphite extrapolation chamber and a free-air chamber. In the case when the water kerma in a phantom is determined from the measurements of air kerma free in air, differences in the order of 10% were found, according to which the database or the kind of spectrum is used. In contrast to this, for the second method, the differences found were about 0.5%.

  10. MCNP simulation of absorbed energy and dose by iodinated contrast agent

    NASA Astrophysics Data System (ADS)

    He, Wenjun; Mah, Eugene; Huda, Walter; Yao, Hai

    2012-03-01

    The purpose of this study is to investigate the absorbed dose and energy by iodinated contrast medium in diagnostic radiology. A simulation geometry in which an inner sphere (d = 0.2cm, 1cm, 5cm) filled with iodinated contrast medium (or water) is located at the center of a 20cm diameter water sphere was used in simulations performed with MCNP5 codes. Monoenergetic x-rays with energies ranging from 40 to 80keV from a cone beam source were utilized and contrast medium concentration ranged from 100 to 1mg/ml. Absorbed dose ratio (RD) to inner sphere and total absorbed energies ratio (RE) to the whole phantom with and without iodinated contrast medium were investigated. The maximum RD was ~13 for the 0.2cm diameter sphere with 100mg/ml contrast medium. The maximum RE was ~1.05 for the 5cm diameter contrast sphere at 80keV with 100mg/ml contrast medium. Under the same incident photon energy, increasing the inner sphere size from 0.2cm to 5cm caused a ~63% increase in the RD on average. Decreasing the contrast medium concentration from 100 to 10 mg/ml caused a decrease of RD of ~ 76%. A conclusion was reached that although local absorbed dose increase caused by iodinated contrast agent could be high; the increase in total absorbed energy is negligible.

  11. Wave based optimization of distributed vibration absorbers

    NASA Astrophysics Data System (ADS)

    Johnson, Marty; Batton, Brad

    2005-09-01

    The concept of distributed vibration absorbers or DVAs has been investigated in recent years as a method of vibration control and sound radiation control for large flexible structures. These devices are comprised of a distributed compliant layer with a distributed mass layer. When such a device is placed onto a structure it forms a sandwich panel configuration with a very soft core. With this configuration the main effect of the DVA is to create forces normal to the surface of the structure and can be used at low frequencies to either add damping, where constrain layer damper treatments are not very effective, or to pin the structure over a narrow frequency bandwidth (i.e., large input impedance/vibration absorber approach). This paper analyses the behavior of these devices using a wave based approach and finds an optimal damping level for the control of broadband disturbances in panels. The optimal design is calculated by solving the differential equations for waves propagating in coupled plates. It is shown that the optimal damping calculated using the infinite case acts as a good ``rule of thumb'' for designing DVAs to control the vibration of finite panels. This is bourn out in both numerical simulations and experiments.

  12. Measurements and calculations of the absorbed dose distribution around a 60Co source.

    PubMed

    Tiourina, T B; Dries, W J; van der Linden, P M

    1995-05-01

    The data from Meisberger et al. [Radiology 90, 953-957 (1968)] are often used as a basis for dose calculations in brachytherapy. In order to describe the absorbed dose in water around a brachytherapy point source, Meisberger provided a polynomial fit for different isotopes taking into account the effect of attenuation and scattering. The validity of the Meisberger coefficients is restricted to distances up to 10 cm from the source, which is regarded to be satisfactory for most brachytherapy applications. However, for more distant organs it may lead to errors in calculated absorbed dose. For this reason dose measurements have been performed in air and in water around a high activity 60Co source used in high dose rate brachytherapy. Measurements were carried out to distances of 20 cm, using ionization chambers. These data show that at a distance of about 15 cm the amount of scattered radiation virtually equals the amount of primary radiation. This emphasizes the contribution of scattered radiation to the dose in healthy tissue far from the target volume, even with relatively high energy photon radiation of 60Co. It is also shown that the Meisberger data as well as the approach of Van Kleffens and Star [Int. J. Radiat. Oncol. Phys. 5, 557-563 (1979)] lead to significant errors in absorbed dose between distances of 10 and 20 cm from the source. In addition to these measurements, the Monte Carlo code has been used to calculate separately primary dose and scattered dose from a cobalt point source. The calculated results agree with the experimental data within 1% for a most distant dose scoring region.

  13. Absorbed dose rates in tissue from prompt gamma emissions from near-thermal neutron absorption

    DOE PAGES

    Schwahn, Scott O.

    2015-10-01

    Prompt gamma emission data from the International Atomic Energy Agency s Prompt Gamma-ray Neutron Activation Analysis database are analyzed to determine the absorbed dose rates in tissue to be expected when natural elements are exposed in a near-thermal neutron environment.

  14. Influence of thyroid volume reduction on absorbed dose in 131I therapy studied by using Geant4 Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Ziaur, Rahman; Sikander, M. Mirza; Waheed, Arshed; Nasir, M. Mirza; Waheed, Ahmed

    2014-05-01

    A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of 131I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid material. A Monte Carlo model of the thyroid, in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume. The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical, ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm3 range. The relative differences of Geant4 results for different models with each other and MCNP results lie well below 1.870%. The maximum relative difference among the Geant4 estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%. S-values for ellipsoidal, spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within 3.095%. The absorbed fraction values for beta particles show a good agreement with published values within 2.105% deviation. The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results (±6.667%) but have 29.032% higher values than that of MIRD calculated values. Consistent with previous studies, the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose. Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially different from MIRD8 data. Therefore, inclusion of size/mass dependence is indicated for 131I radiotherapy of the thyroid.

  15. Verification of absorbed dose using diodes in cobalt-60 radiation therapy.

    PubMed

    Gadhi, Muhammad Asghar; Fatmi, Shahab; Chughtai, Gul M; Arshad, Muhammad; Shakil, Muhammad; Rahmani, Uzma Mahmood; Imran, Malik Younas; Buzdar, Saeed Ahmad

    2016-03-01

    The objective of this work was to enhance the quality and safety of dose delivery in the practice of radiation oncology. To achieve this goal, the absorbed dose verification program was initiated by using the diode in vivo dosimetry (IVD) system (for entrance and exit). This practice was implemented at BINO, Bahawalpur, Pakistan. Diodes were calibrated for making absorbed dose measurements. Various correction factors (SSD, dose non-linearity, field size, angle of incidence, and wedge) were determined for diode IVD system. The measurements were performed in phantom in order to validate the IVD procedure. One hundred and nineteen patients were monitored and 995 measurements were performed. For phantom, the percentage difference between measured and calculated dose for entrance setting remained within ±2% and for exit setting ±3%. For patient measurements, the percentage difference between measured and calculated dose remained within ±5% for entrance/open fields and ±7% for exit/wedge/oblique fields. One hundred and nineteen patients and 995 fields have been monitored during the period of 6 months. The analysis of all available measurements gave a mean percent deviation of ±1.19% and standard deviation of ±2.87%. Larger variations have been noticed in oblique, wedge and exit measurements. This investigation revealed that clinical dosimetry using diodes is simple, provides immediate results and is a useful quality assurance tool for dose delivery. It has enhanced the quality of radiation dose delivery and increased/improved the reliability of the radiation therapy practice in BINO.

  16. Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code

    NASA Astrophysics Data System (ADS)

    Ziaur, Rahman; Shakeel, ur Rehman; Waheed, Arshed; Nasir, M. Mirza; Abdul, Rashid; Jahan, Zeb

    2012-11-01

    The aim of this study is to compare the absorbed doses of critical organs of 131I using the MIRD (Medical Internal Radiation Dose) with the corresponding predictions made by GEANT4 simulations. S-values (mean absorbed dose rate per unit activity) and energy deposition per decay for critical organs of 131I for various ages, using standard cylindrical phantom comprising water and ICRP soft-tissue material, have also been estimated. In this study the effect of volume reduction of thyroid, during radiation therapy, on the calculation of absorbed dose is also being estimated using GEANT4. Photon specific energy deposition in the other organs of the neck, due to 131I decay in the thyroid organ, has also been estimated. The maximum relative difference of MIRD with the GEANT4 simulated results is 5.64% for an adult's critical organs of 131I. Excellent agreement was found between the results of water and ICRP soft tissue using the cylindrical model. S-values are tabulated for critical organs of 131I, using 1, 5, 10, 15 and 18 years (adults) individuals. S-values for a cylindrical thyroid of different sizes, having 3.07% relative differences of GEANT4 with Siegel & Stabin results. Comparison of the experimentally measured values at 0.5 and 1 m away from neck of the ionization chamber with GEANT4 based Monte Carlo simulations results show good agreement. This study shows that GEANT4 code is an important tool for the internal dosimetry calculations.

  17. Absorbed dose measurements for kV-cone beam computed tomography in image-guided radiation therapy

    NASA Astrophysics Data System (ADS)

    Hioki, Kazunari; Araki, Fujio; Ohno, Takeshi; Nakaguchi, Yuji; Tomiyama, Yuuki

    2014-12-01

    In this study, we develope a novel method to directly evaluate an absorbed dose-to-water for kilovoltage-cone beam computed tomography (kV-CBCT) in image-guided radiation therapy (IGRT). Absorbed doses for the kV-CBCT systems of the Varian On-Board Imager (OBI) and the Elekta X-ray Volumetric Imager (XVI) were measured by a Farmer ionization chamber with a 60Co calibration factor. The chamber measurements were performed at the center and four peripheral points in body-type (30 cm diameter and 51 cm length) and head-type (16 cm diameter and 33 cm length) cylindrical water phantoms. The measured ionization was converted to the absorbed dose-to-water by using a 60Co calibration factor and a Monte Carlo (MC)-calculated beam quality conversion factor, kQ, for 60Co to kV-CBCT. The irradiation for OBI and XVI was performed with pelvis and head modes for the body- and the head-type phantoms, respectively. In addition, the dose distributions in the phantom for both kV-CBCT systems were calculated with MC method and were compared with measured values. The MC-calculated doses were calibrated at the center in the water phantom and compared with measured doses at four peripheral points. The measured absorbed doses at the center in the body-type phantom were 1.96 cGy for OBI and 0.83 cGy for XVI. The peripheral doses were 2.36-2.90 cGy for OBI and 0.83-1.06 cGy for XVI. The doses for XVI were lower up to approximately one-third of those for OBI. Similarly, the measured doses at the center in the head-type phantom were 0.48 cGy for OBI and 0.21 cGy for XVI. The peripheral doses were 0.26-0.66 cGy for OBI and 0.16-0.30 cGy for XVI. The calculated peripheral doses agreed within 3% in the pelvis mode and within 4% in the head mode with measured doses for both kV-CBCT systems. In addition, the absorbed dose determined in this study was approximately 4% lower than that in TG-61 but the absorbed dose by both methods was in agreement within their combined

  18. Electron absorbed fractions and dose conversion factors for marrow and bone by skeletal regions

    SciTech Connect

    Eckerman, K.F.; Stabin, M.G.

    2000-02-01

    The possible inductions of bone cancer and leukemia are the two health effects of primary concern in the irradiation of the skeleton. The relevant target tissues to consider in the dosimetric evaluation have been the cells on or near endosteal surfaces of bone, from which osteosarcomas are thought to arise, and hematopoietic bone marrow, which is associated with leukemia. The complex geometry of the soft tissue-bone intermixture makes calculations of absorbed doses to these target regions a difficult problem. In the case of photon or neutron radiations, charged particle equilibrium may not exist in the vicinity of a soft tissue-bone mineral interface. In this paper, absorbed fraction data are developed for calculations of the dose in the target tissues from electron emitters deposited within the volume or on the surfaces of trabecular bone. The skeletal average absorbed fractions presented are consistent with usage of this quantity in the contemporary dosimetric formulations of the International Commission on Radiological Protection (ICRP). Implementation of the new bone and marrow model is then developed within the context of the calculational schema of the Medical Internal Radiation Dose (MIRD) Committee. Model parameters relevant to the calculation of dose conversion factors (S values) for different regions of the skeleton of individuals of various age are described, and an example calculation is performed for a monoclonal antibody which localizes in the marrow. The utility of these calculations for radiation dose calculations in nuclear medicine is discussed.

  19. Absorbed dose measurements on external surface of Kosmos-satellites with glass thermoluminescent detectors.

    PubMed

    Akatov YuA; Arkhangelsky, V V; Kovalev, E E; Spurny, F; Votochkova, I

    1989-01-01

    In this paper we present absorbed dose measurements with glass thermoluminescent detectors on external surface of satellites of Kosmos-serie flying in 1983-87. Experiments were performed with thermoluminescent aluminophosphate glasses of thicknesses 0.1, 0.3, 0.4, 0.5, and 1 mm. They were exposed in sets of total thickness between 5 and 20 mm, which were protected against sunlight with thin aluminized foils. In all missions, extremely high absorbed dose values were observed in the first layers of detectors, up to the thickness of 0.2 to 0.5 gcm-2. These experimental results confirm that, during flights at 250 to 400 km, doses on the surface of the satellites are very high, due to the low energy component of the proton and electron radiation.

  20. Uneven surface absorbed dose distribution in electron-accelerator irradiation of rubber items

    SciTech Connect

    Gorbunov, I.F.; Pashinin, V.I.; Vanyushkin, B.M.

    1988-02-01

    Electron accelerators for industrial use are equipped with scanning devices, where the scan frequency or linear velocity along the window may vary. In a flow technology, where the items are transported to the irradiation zone at a set rate, the speed of an item may be comparable with the scan speed, so there is substantial nonuniformity in the absorbed dose, which adversely affects the quality. We have examined the dose nonuniformity for long rubber items during vulcanization by means of LUE-8-5RV and ELV-2 accelerators. The absorbed dose is calculated for an elementary part along which the irradiation is uniform on the assumption that current density distribution in the unswept beam is uniform as a result of scattering in the foil.

  1. Graphene metamaterials based tunable terahertz absorber: effective surface conductivity approach.

    PubMed

    Andryieuski, Andrei; Lavrinenko, Andrei V

    2013-04-08

    In this paper we present the efficient design of functional thin-film metamaterial devices with the effective surface conductivity approach. As an example, we demonstrate a graphene based perfect absorber. After formulating the requirements to the perfect absorber in terms of surface conductivity we investigate the properties of graphene wire medium and graphene fishnet metamaterials and demonstrate both narrowband and broadband tunable absorbers.

  2. Radiation absorbed doses from iron-52, iron-55, and iron-59 used to study ferrokinetics

    SciTech Connect

    Robertson, J.S.; Price, R.R.; Budinger, T.F.; Fairbanks, V.F.; Pollycove, M.

    1983-04-01

    Biological data obtained principally with Fe-59 citrate are used with physical data to calculate radiation absorbed doses for ionic or weak chelate forms of Fe-52, Fe-55, and Fe-59, administered by intravenous injection. Doses are calculated for normal subjects, primary hemochromatosis (also called idiopathic or hereditary hemochromatosis), pernicious anemia in relapse, iron-deficiency anemia, and polycythemia vera. The Fe-52 doses include the dose from the Mn-52m daughter generated after injection of Fe-52. Special attention has been given to the dose to the spleen, which has a relatively high concentration of RBCs and therefore of radioiron, and which varies significantly in size in both health and disease.

  3. Microdosimetric measurements for neutron-absorbed dose determination during proton therapy

    PubMed Central

    Pérez-Andújar, Angélica; DeLuca, Paul M.; Thornton, Allan F.; Fitzek, Markus; Hecksel, Draik; Farr, Jonathan

    2012-01-01

    This work presents microdosimetric measurements performed at the Midwest Proton Radiotherapy Institute in Bloomington, Indiana, USA. The measurements were done simulating clinical setups with a water phantom and for a variety of stopping targets. The water phantom was irradiated by a proton spread out Bragg peak (SOBP) and by a proton pencil beam. Stopping target measurements were performed only for the pencil beam. The targets used were made of polyethylene, brass and lead. The objective of this work was to determine the neutron-absorbed dose for a passive and active proton therapy delivery, and for the interactions of the proton beam with materials typically in the beam line of a proton therapy treatment nozzle. Neutron doses were found to be higher at 45° and 90° from the beam direction for the SOBP configuration by a factor of 1.1 and 1.3, respectively, compared with the pencil beam. Meanwhile, the pencil beam configuration produced neutron-absorbed doses 2.2 times higher at 0° than the SOBP. For stopping targets, lead was found to dominate the neutron-absorbed dose for most angles due to a large production of low-energy neutrons emitted isotropically. PMID:22334761

  4. An international dosimetry exchange for boron neutron capture therapy. Part I: Absorbed dose measurements.

    PubMed

    Binns, P J; Riley, K J; Harling, O K; Kiger, W S; Munck af Rosenschöld, P M; Giusti, V; Capala, J; Sköld, K; Auterinen, I; Serén, T; Kotiluoto, P; Uusi-Simola, J; Marek, M; Viererbl, L; Spurny, F

    2005-12-01

    An international collaboration was organized to undertake a dosimetry exchange to enable the future combination of clinical data from different centers conducting neutron capture therapy trials. As a first step (Part I) the dosimetry group from the Americas, represented by MIT, visited the clinical centers at Studsvik (Sweden), VTT Espoo (Finland), and the Nuclear Research Institute (NRI) at Rez (Czech Republic). A combined VTT/NRI group reciprocated with a visit to MIT. Each participant performed a series of dosimetry measurements under equivalent irradiation conditions using methods appropriate to their clinical protocols. This entailed in-air measurements and dose versus depth measurements in a large water phantom. Thermal neutron flux as well as fast neutron and photon absorbed dose rates were measured. Satisfactory agreement in determining absorbed dose within the experimental uncertainties was obtained between the different groups although the measurement uncertainties are large, ranging between 3% and 30% depending upon the dose component and the depth of measurement. To improve the precision in the specification of absorbed dose amongst the participants, the individually measured dose components were normalized to the results from a single method. Assuming a boron concentration of 15 microg g(-1) that is typical of concentrations realized clinically with the boron delivery compound boronophenylalanine-fructose, systematic discrepancies in the specification of the total biologically weighted dose of up to 10% were apparent between the different groups. The results from these measurements will be used in future to normalize treatment plan calculations between the different clinical dosimetry protocols as Part II of this study.

  5. Comparison of various techniques for the exact determination of absorbed dose in heavy ion fields using passive detectors

    NASA Astrophysics Data System (ADS)

    Berger, T.; Reitz, G.; Hajek, M.; Vana, N.

    Passive thermoluminescent detectors (TLDs) are commonly applied for the determination of absorbed dose in routine radiation protection. The usage of TLDs in heavy ion fields, e.g. for treatment planing in radiotherapy or in space dosimetry, requires the detailed knowledge of the efficiency of these detectors to the ion under study in dependence on the LET of the ion. This is due to the fact, that the detection efficiency of TLDs changes with increasing LET. This would lead - if the changing efficiency of the TL- material is not taken into account - to a measured deviation of the absorbed dose. In the framework of the ICCHIBAN project - which was started as an intercomparison of passive and active detector systems used for dose determination in space - "Blind" exposures were carried out. No information about dose and ion species was given for the investigators. Three different methods were used for the efficiency correction of TLDs after the BLIND exposures. The first method used the different LET efficiency of the TL-materials LiF: Mg, Ti and LiF:Mg, Cu,P to determine the LET and based on this value the efficiency of the LiF: Mg, Ti dosemeters. The second method used the high temperature emissions in LiF: Mg, Ti for the efficiency correction. The third method applied used a combination of TLDs and CR-39 track etch detectors to determine the total absorbed dose during the BLIND exposures. The paper will discuss the threee methods, and focus on the applicability for the usage of these methods for dose determination and recalculation in space dosimetry.

  6. Determination of the absorbed dose and the average LET of space radiation in dependence on shielding conditions.

    PubMed

    Vana, N; Schoner, W; Noll, M; Fugger, M; Akatov, Y; Shurshakov, V

    1999-01-01

    The HTR method, developed for determination of absorbed dose and average LET of mixed radiation fields in space, was applied during several space missions on space station MIR, space shuttles and satellites. The method utilises the changes of peak height ratios in the glow curves in dependence on the linear energy transfer LET. Due to the small size of the dosemeters the evaluation of the variation of absorbed dose and average LET in dependence on the position of the dosemeters inside the space station is possible. The dose and LET distribution was determined during the experiment ADLET where dosemeters were exposed in two positions with different shielding conditions and during two following experiments (MIR-95, MIR-96) using six positions inside the space station. The results were compared with the shielding conditions of the positions. Calculations of the absorbed dose were carried out for comparison. Results have shown that the average LET increases with increasing absorbing thickness while the absorbed dose decreases.

  7. Deterministic absorbed dose estimation in computed tomography using a discrete ordinates method

    SciTech Connect

    Norris, Edward T.; Liu, Xin; Hsieh, Jiang

    2015-07-15

    Purpose: Organ dose estimation for a patient undergoing computed tomography (CT) scanning is very important. Although Monte Carlo methods are considered gold-standard in patient dose estimation, the computation time required is formidable for routine clinical calculations. Here, the authors instigate a deterministic method for estimating an absorbed dose more efficiently. Methods: Compared with current Monte Carlo methods, a more efficient approach to estimating the absorbed dose is to solve the linear Boltzmann equation numerically. In this study, an axial CT scan was modeled with a software package, Denovo, which solved the linear Boltzmann equation using the discrete ordinates method. The CT scanning configuration included 16 x-ray source positions, beam collimators, flat filters, and bowtie filters. The phantom was the standard 32 cm CT dose index (CTDI) phantom. Four different Denovo simulations were performed with different simulation parameters, including the number of quadrature sets and the order of Legendre polynomial expansions. A Monte Carlo simulation was also performed for benchmarking the Denovo simulations. A quantitative comparison was made of the simulation results obtained by the Denovo and the Monte Carlo methods. Results: The difference in the simulation results of the discrete ordinates method and those of the Monte Carlo methods was found to be small, with a root-mean-square difference of around 2.4%. It was found that the discrete ordinates method, with a higher order of Legendre polynomial expansions, underestimated the absorbed dose near the center of the phantom (i.e., low dose region). Simulations of the quadrature set 8 and the first order of the Legendre polynomial expansions proved to be the most efficient computation method in the authors’ study. The single-thread computation time of the deterministic simulation of the quadrature set 8 and the first order of the Legendre polynomial expansions was 21 min on a personal computer

  8. Calculation of fluence and absorbed dose in head tissues due to different photon energies.

    PubMed

    Azorín, C; Vega-Carrillo, H R; Rivera, T; Azorín, J

    2014-01-01

    Calculations of fluence and absorbed dose in head tissues due to different photon energies were carried out using the MCNPX code, to simulate two models of a patient's head: one spherical and another more realistic ellipsoidal. Both head models had concentric shells to describe the scalp skin, the cranium and the brain. The tumor was located at the center of the head and it was a 1 cm-radius sphere. The MCNPX code was run for different energies. Results showed that the fluence decreases as the photons pass through the different head tissues. It can be observed that, although the fluence into the tumor is different for both head models, absorbed dose is the same.

  9. Absorbed doses and energy imparted from radiographic examination of velopharyngeal function during speech

    SciTech Connect

    Isberg, A.; Julin, P.; Kraepelien, T.; Henrikson, C.O. )

    1989-04-01

    Absorbed doses of radiation were measured by thermoluminescent dosimeters (TLDs) using a skull phantom during simulated cinefluorographic and videofluorographic examination of velopharyngeal function in frontal and lateral projections. Dosages to the thyroid gland, the parotid gland, the pituitary gland, and ocular lens were measured. Radiation dosage was found to be approximately 10 times less for videofluoroscopy when compared with that of cinefluoroscopy. In addition, precautionary measures were found to reduce further the exposure of radiation-sensitive tissues. Head fixation and shielding resulted in dose reduction for both video- and cinefluoroscopy. Pulsing exposure for cinefluoroscopy also reduced the dosage.

  10. [Absorbed dose conversion factors obtained from X-ray spectra measured at water phantom surface].

    PubMed

    Aoki, Kiyoshi; Koyama, Masaki

    2005-03-20

    The absorbed dose conversion factor for X-rays at the water phantom surface has been obtained from the measured spectra. These measurements have been made at tube voltages of 60 kV to 120 kV and field sizes ranging from 5 x 5 cm(2) to 30 x 30 cm(2) with and without additional 2 mm aluminium filtration. A small silicon diode detector with little angular dependence was used for this measurement. The absorbed dose conversion factor obtained was 0.03-0.43% smaller than that obtained from the primary X-ray spectrum. The difference was large for high-voltage and heavily filtered X-rays. As field size increases, the conversion factor decreases, but the decrease is slight when field size exceeds 20 x 20 cm(2). The absorbed dose conversion factor obtained from the primary or surface X-ray spectrum is 0.4-1.8% larger than that obtained from the effective energy of primary X-rays. The difference is large in high-voltage X-rays and decreases slightly with increases in field size.

  11. Influence of lead apron shielding on absorbed doses from cone-beam computed tomography.

    PubMed

    Rottke, Dennis; Andersson, Jonas; Ejima, Ken-Ichiro; Sawada, Kunihiko; Schulze, Dirk

    2016-09-24

    The aim of the present work was to investigate absorbed and to calculate effective doses (EDs) in cone-beam computed tomography (CBCT). The study was conducted using examination protocols with and without lead apron shielding. A full-body male RANDO(®) phantom was loaded with 110 GR200A thermoluminescence dosemeter chips at 55 different sites and set up in two different CBCT systems (CS 9500(®), ProMax(®) 3D). Two different protocols were performed: the phantom was set up (1) with and (2) without a lead apron. No statistically significant differences in organ and absorbed doses from regions outside the primary beam could be found when comparing results from exposures with and without lead apron shielding. Consequently, calculating the ED showed no significant differences between the examination protocols with and without lead apron shielding. For the ProMax(®) 3D with shielding, the ED was 149 µSv, and for the examination protocol without shielding 148 µSv (SD = 0.31 µSv). For the CS 9500(®), the ED was 88 and 86 µSv (SD = 0.95 µSv), respectively, with and without lead apron shielding. The results revealed no statistically significant differences in the absorbed doses between examination with and without lead apron shielding, especially in organs outside the primary beam.

  12. Mycosis Fungoides electron beam absorbed dose distribution using Fricke xylenol gel dosimetry

    NASA Astrophysics Data System (ADS)

    da Silveira, Michely C.; Sampaio, Francisco G. A.; Petchevist, Paulo C. D.; de Oliveira, André L.; Almeida, Adelaide de

    2011-12-01

    Radiotherapy uses ionizing radiation to destroy tumor cells. The absorbed dose control in the target volume is realized through radiation sensors, such as Fricke dosimeters and radiochromic film, which permit to realize bi-dimensional evaluations at once and because of that, they will be used in this study as well. Among the several types of cancer suitable for ionizing radiation treatment, the Mycosis Fungoides, a lymphoma that spreads on the skin surface and depth, requires for its treatment total body irradiation by high-energy electrons. In this work the Fricke xylenol gel (FXG) was used in order to obtain information about the absorbed dose distribution induced by the electron interactions with the irradiated tissues and to control this type of treatment. FXG can be considered as an alternative dosimeter, since up to now only films have been used. FXG sample cuvettes, simulating two selected tomos (cranium and abdomen) of the Rando anthropomorphic phantom, were positioned along with radiochromic films for comparison. The phantom was subjected to Stanford total body irradiation using 6 MeV electrons. Tomographic images were acquired for both dosimeters and evaluated through horizontal and vertical profiles along the tomographic centers. These profiles were obtained through a Matlab routine developed for this purpose. From the obtained results, one could infer that, for a superficial and internal patient irradiation, the FXG dosimeter showed an absorbed dose distribution similar to the one of the film. These results can validate the FXG dosimeter as an alternative dosimeter for the Mycosis Fungoides treatment planning.

  13. On the suitability of ultrathin detectors for absorbed dose assessment in the presence of high-density heterogeneities

    SciTech Connect

    Bueno, M. Duch, M. A.; Carrasco, P.; Jornet, N.; Muñoz-Montplet, C.

    2014-08-15

    Purpose: The aim of this study was to evaluate the suitability of several detectors for the determination of absorbed dose in bone. Methods: Three types of ultrathin LiF-based thermoluminescent dosimeters (TLDs)—two LiF:Mg,Cu,P-based (MCP-Ns and TLD-2000F) and a{sup 7}Li-enriched LiF:Mg,Ti-based (MTS-7s)—as well as EBT2 Gafchromic films were used to measure percentage depth-dose distributions (PDDs) in a water-equivalent phantom with a bone-equivalent heterogeneity for 6 and 18 MV and a set of field sizes ranging from 5×5 cm{sup 2} to 20×20 cm{sup 2}. MCP-Ns, TLD-2000F, MTS-7s, and EBT2 have active layers of 50, 20, 50, and 30 μm, respectively. Monte Carlo (MC) dose calculations (PENELOPE code) were used as the reference and helped to understand the experimental results and to evaluate the potential perturbation of the fluence in bone caused by the presence of the detectors. The energy dependence and linearity of the TLDs’ response was evaluated. Results: TLDs exhibited flat energy responses (within 2.5%) and linearity with dose (within 1.1%) within the range of interest for the selected beams. The results revealed that all considered detectors perturb the electron fluence with respect to the energy inside the bone-equivalent material. MCP-Ns and MTS-7s underestimated the absorbed dose in bone by 4%–5%. EBT2 exhibited comparable accuracy to MTS-7s and MCP-Ns. TLD-2000F was able to determine the dose within 2% accuracy. No dependence on the beam energy or field size was observed. The MC calculations showed that a50 μm thick detector can provide reliable dose estimations in bone regardless of whether it is made of LiF, water or EBT’s active layer material. Conclusions: TLD-2000F was found to be suitable for providing reliable absorbed dose measurements in the presence of bone for high-energy x-ray beams.

  14. SU-E-I-85: Absorbed Dose Estimation for a Commercially Available MicroCT Scanner

    SciTech Connect

    Lau, A; Ahmad, S; Chen, Y; Ren, L; Liu, H; Yang, K

    2015-06-15

    Purpose: To quantify the simulated absorbed dose delivered for a typical scan from a commercially available microCT scanner in order to aid in the dose estimation. Methods: The simulations were conducted using the Geant4 Monte Carlo Toolkit (version 10) with the standard electromagnetic classes. The Quantum FX microCT scanner (PerkinElmer, Waltham, MA) was modeled incorporating the energy fluence and angular distributions of generated photons, spatial dimensions of nominal source-to-object and source-to-detector distances. The energy distribution was measured using a spectrometer (X-123CdTe, Amptek Inc., Bedford, USA) with a 300 angular spread from the source for the 90 kVp X-ray beams with no additional filtration. The nominal distances from the source to object consisted of three setups: 154.0 mm, 104.0 mm, and 51.96 mm. Our simulations recorded the dose absorbed in a cylindrical phantom of PMMA with a fixed length of 2 cm and varying radii (10, 20, 30 and 40 mm) using 100 million incident photons. The averaged absorbed dose in the object was then quantified for all setups. An exposure measurement of 417 mR was taken using a Radcal 9095 system utilizing 10×9–180 ion chamber with the given technique of 90 kVp, 63 μA, and 12 s. The exposure rate was also simulated with same setup to calculate the conversion factor of the beam current and the number of incident photons. Results: For a typical cone-beam scan with non-filtered 90kVp, the dose coefficients (the absorbed dose per mAs) were 2.614, 2.549 and 2.467 μGy/mAs under source to object distance of 104 mm for the object diameters of 10 mm, 20 mm and 30 mm, respectively. Conclusion: A look-up table was developed where an investigator can estimate the delivered dose using this particular microCT given the scanning protocol (kVp and mAs) as well as the size of the scanned object.

  15. Differential absorbed dose distributions in lineal energy for neutrons and gamma rays at the mono-energetic neutron calibration facility.

    PubMed

    Takada, M; Baba, M; Yamaguchi, H; Fujitaka, K

    2005-01-01

    Absorbed dose distributions in lineal energy for neutrons and gamma rays of mono-energetic neutron sources from 140 keV to 15 MeV were measured in the Fast Neutron Laboratory at Tohoku University. By using both a tissue-equivalent plastic walled counter and a graphite-walled low-pressure proportional counter, absorbed dose distributions in lineal energy for neutrons were obtained separately from those for gamma rays. This method needs no knowledge of energy spectra and dose distributions for gamma rays. The gamma-ray contribution in this neutron calibration field >1 MeV neutron was <3%, while for <550 keV it was >40%. The measured neutron absolute absorbed doses per unit neutron fluence agreed with the LA150 evaluated kerma factors. By using this method, absorbed dose distributions in lineal energy for neutrons and gamma rays in an unknown neutron field can be obtained separately.

  16. Distribution of absorbed doses in the materials irradiated by ''RHODOTRON'' electron accelerator: Experiment and Monte Carlo simulations

    SciTech Connect

    Oleg E. Krivosheev et al.

    2001-07-02

    This paper describes the experimental setup and presents studies of absorbed doses in different metals and dielectrics along with corresponding Monte Carlo energy deposition simulations. Experiments were conducted using a 5 MeV electron accelerator. We used several Monte Carlo code systems, namely MARS, MCNP, and GEANT to simulate the absorbed doses under the same conditions as in experiment. We compare calculated and measured high and low absorbed doses (from few kGy to hundreds kGy) and discuss the applicability of these computer codes for applied accelerator dosimetry.

  17. PHITS simulations of absorbed dose out-of-field and neutron energy spectra for ELEKTA SL25 medical linear accelerator

    NASA Astrophysics Data System (ADS)

    Puchalska, Monika; Sihver, Lembit

    2015-06-01

    Monte Carlo (MC) based calculation methods for modeling photon and particle transport, have several potential applications in radiotherapy. An essential requirement for successful radiation therapy is that the discrepancies between dose distributions calculated at the treatment planning stage and those delivered to the patient are minimized. It is also essential to minimize the dose to radiosensitive and critical organs. With MC technique, the dose distributions from both the primary and scattered photons can be calculated. The out-of-field radiation doses are of particular concern when high energy photons are used, since then neutrons are produced both in the accelerator head and inside the patients. Using MC technique, the created photons and particles can be followed and the transport and energy deposition in all the tissues of the patient can be estimated. This is of great importance during pediatric treatments when minimizing the risk for normal healthy tissue, e.g. secondary cancer. The purpose of this work was to evaluate 3D general purpose PHITS MC code efficiency as an alternative approach for photon beam specification. In this study, we developed a model of an ELEKTA SL25 accelerator and used the transport code PHITS for calculating the total absorbed dose and the neutron energy spectra infield and outside the treatment field. This model was validated against measurements performed with bubble detector spectrometers and Boner sphere for 18 MV linacs, including both photons and neutrons. The average absolute difference between the calculated and measured absorbed dose for the out-of-field region was around 11%. Taking into account a simplification for simulated geometry, which does not include any potential scattering materials around, the obtained result is very satisfactorily. A good agreement between the simulated and measured neutron energy spectra was observed while comparing to data found in the literature.

  18. PHITS simulations of absorbed dose out-of-field and neutron energy spectra for ELEKTA SL25 medical linear accelerator.

    PubMed

    Puchalska, Monika; Sihver, Lembit

    2015-06-21

    Monte Carlo (MC) based calculation methods for modeling photon and particle transport, have several potential applications in radiotherapy. An essential requirement for successful radiation therapy is that the discrepancies between dose distributions calculated at the treatment planning stage and those delivered to the patient are minimized. It is also essential to minimize the dose to radiosensitive and critical organs. With MC technique, the dose distributions from both the primary and scattered photons can be calculated. The out-of-field radiation doses are of particular concern when high energy photons are used, since then neutrons are produced both in the accelerator head and inside the patients. Using MC technique, the created photons and particles can be followed and the transport and energy deposition in all the tissues of the patient can be estimated. This is of great importance during pediatric treatments when minimizing the risk for normal healthy tissue, e.g. secondary cancer. The purpose of this work was to evaluate 3D general purpose PHITS MC code efficiency as an alternative approach for photon beam specification. In this study, we developed a model of an ELEKTA SL25 accelerator and used the transport code PHITS for calculating the total absorbed dose and the neutron energy spectra infield and outside the treatment field. This model was validated against measurements performed with bubble detector spectrometers and Boner sphere for 18 MV linacs, including both photons and neutrons. The average absolute difference between the calculated and measured absorbed dose for the out-of-field region was around 11%. Taking into account a simplification for simulated geometry, which does not include any potential scattering materials around, the obtained result is very satisfactorily. A good agreement between the simulated and measured neutron energy spectra was observed while comparing to data found in the literature.

  19. A control strategy for adaptive absorber based on variable mass

    NASA Astrophysics Data System (ADS)

    Gao, Qiang; Han, Ning; Zhao, Yanqing; Duan, Chendong; Wang, Wanqin

    2015-07-01

    The tuned vibration absorber (TVA) has been an effective tool for vibration control. However, the application of TVA can cause resonance of the primary system and increase its vibration when the absorber is mistuned. In this paper, a novel control strategy based on adaptive tuned vibration absorber (ATVA) of variable mass is proposed to reduce the resonance of the primary system. Unlike most ATVAs suggested by other researchers which adjust the absorber natural frequency by changing the stiffness, the variable mass ATVA varies its natural frequency by changing absorber mass to match the excitation frequency. Some simulations and experiments were conducted to test the performance of the control strategy. The results show that the proposed control plan can widen the frequency bandwidth of the absorber, as well as suppress the resonance of the primary system significantly. This implies that the work is useful for practical applications of ATVA.

  20. Relative Efficiency of TLD-100 to High Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Cash, B. L.; Semones, E. J.; Yasuda, H.; Fujitaka, K.

    1999-01-01

    Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to 137Cs) dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

  1. Relative Efficiency of TLD-100 to Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

    NASA Technical Reports Server (NTRS)

    Badhwar, Gautam D.; Cash, B. L.; Semones, E. J.; Yasuda, H.; Fujitaka, K.

    1999-01-01

    Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to (137)Cs dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

  2. Dual band metamaterial perfect absorber based on artificial dielectric "molecules".

    PubMed

    Liu, Xiaoming; Lan, Chuwen; Li, Bo; Zhao, Qian; Zhou, Ji

    2016-07-13

    Dual band metamaterial perfect absorbers with two absorption bands are highly desirable because of their potential application areas such as detectors, transceiver system, and spectroscopic imagers. However, most of these dual band metamaterial absorbers proposed were based on resonances of metal patterns. Here, we numerically and experimentally demonstrate a dual band metamaterial perfect absorber composed of artificial dielectric "molecules" with high symmetry. The artificial dielectric "molecule" consists of four "atoms" of two different sizes corresponding to two absorption bands with near unity absorptivity. Numerical and experimental absorptivity verify that the dual-band metamaterial absorber is polarization insensitive and can operate in wide-angle incidence.

  3. Absorbed dose determination in kilovoltage X-ray synchrotron radiation using alanine dosimeters.

    PubMed

    Butler, D J; Lye, J E; Wright, T E; Crossley, D; Sharpe, P H G; Stevenson, A W; Livingstone, J; Crosbie, J C

    2016-12-01

    Alanine dosimeters from the National Physical Laboratory (NPL) in the UK were irradiated using kilovoltage synchrotron radiation at the imaging and medical beam line (IMBL) at the Australian Synchrotron. A 20 × 20 mm(2) area was irradiated by scanning the phantom containing the alanine through the 1 mm × 20 mm beam at a constant velocity. The polychromatic beam had an average energy of 95 keV and nominal absorbed dose to water rate of 250 Gy/s. The absorbed dose to water in the solid water phantom was first determined using a PTW Model 31014 PinPoint ionization chamber traceable to a graphite calorimeter. The alanine was read out at NPL using correction factors determined for (60)Co, traceable to NPL standards, and a published energy correction was applied to correct for the effect of the synchrotron beam quality. The ratio of the doses determined by alanine at NPL and those determined at the synchrotron was 0.975 (standard uncertainty 0.042) when alanine energy correction factors published by Waldeland et al. (Waldeland E, Hole E O, Sagstuen E and Malinen E, Med. Phys. 2010, 37, 3569) were used, and 0.996 (standard uncertainty 0.031) when factors by Anton et al. (Anton M, Büermann L., Phys Med Biol. 2015 60 6113-29) were used. The results provide additional verification of the IMBL dosimetry.

  4. Technique-dependent decrease in thyroid absorbed dose for dental radiography.

    PubMed

    Wood, R E; Bristow, R G; Clark, G M; Nussbaum, C; Taylor, K W

    1989-06-01

    A LiF thermoluminescent dosimetry (TLD) system, calibrated in the tissue of interest with the beam used for experimentation, was employed to investigate dosages (muGy) to the thyroid region of an anthropomorphic phantom resultant from two dental complete-mouth radiographic procedures. Both techniques were compared in terms of dosages associated with combinations of lead apron and thyroid collar shielding while using a 70-kVp or 90-kVp x-ray beam for a 20-film complete-mouth series. Lead shielding significantly decreased the dose to the thyroid using both techniques (p less than 0.05). The use of the 90-kVp beam resulted in a significant reduction in the thyroid absorbed dose when using the bisecting angle technique (p less than 0.05) but caused a significant increase in the thyroid absorbed dose when the paralleling technique was used (p less than 0.05). The implementation of higher kilovoltage techniques in dental offices must therefore be dependent on the radiographic technique employed.

  5. Technique-dependent decrease in thyroid absorbed dose for dental radiography

    SciTech Connect

    Wood, R.E.; Bristow, R.G.; Clark, G.M.; Nussbaum, C.; Taylor, K.W.

    1989-06-01

    A LiF thermoluminescent dosimetry (TLD) system, calibrated in the tissue of interest with the beam used for experimentation, was employed to investigate dosages (muGy) to the thyroid region of an anthropomorphic phantom resultant from two dental complete-mouth radiographic procedures. Both techniques were compared in terms of dosages associated with combinations of lead apron and thyroid collar shielding while using a 70-kVp or 90-kVp x-ray beam for a 20-film complete-mouth series. Lead shielding significantly decreased the dose to the thyroid using both techniques (p less than 0.05). The use of the 90-kVp beam resulted in a significant reduction in the thyroid absorbed dose when using the bisecting angle technique (p less than 0.05) but caused a significant increase in the thyroid absorbed dose when the paralleling technique was used (p less than 0.05). The implementation of higher kilovoltage techniques in dental offices must therefore be dependent on the radiographic technique employed.

  6. Contribution to Neutron Fluence and Neutron Absorbed Dose from Double Scattering Proton Therapy System Components

    PubMed Central

    Pérez-Andújar, A.; Newhauser, W. D.; DeLuca, P. M.

    2010-01-01

    Proton therapy offers low integral dose and good tumor comformality in many deep-seated tumors. However, secondary particles generated during proton therapy, such as neutrons, are a concern, especially for passive scattering systems. In this type of system, the proton beam interacts with several components of the treatment nozzle that lie along the delivery path and can produce secondary neutrons. Neutron production along the beam's central axis in a double scattering passive system was examined using Monte Carlo simulations. Neutron fluence and energy distribution were determined downstream of the nozzle's major components at different radial distances from the central axis. In addition, the neutron absorbed dose per primary proton around the nozzle was investigated. Neutron fluence was highest immediately downstream of the range modulator wheel (RMW) but decreased as distance from the RMW increased. The nozzle's final collimator and snout also contributed to the production of high-energy neutrons. In fact, for the smallest treatment volume simulated, the neutron absorbed dose per proton at isocenter increased by a factor of 20 due to the snout presence when compared with a nozzle without a snout. The presented results can be used to design more effective local shielding components inside the treatment nozzle as well as to better understand the treatment room shielding requirements. PMID:20871789

  7. SU-FF-T-390: In-Vivo Prostate Brachytherapy Absorbed Dose Measurements

    SciTech Connect

    Gueye, Paul; Velasco, Carlos; Keppel, Cynthia; Murphy, B; Sinesi, C

    2009-06-01

    Purpose: In-vivo prostate brachytherapy absorbed dosimetrydetector using scintillating fibers. Method and Materials: Five pairs of 85.5 {+-} 0.05 cm long blue shifted scintillating fibers (model BCF-10) with 1 mm{sup 2} cross sectional area were placed in a mixture of gelatin (368.6 {+-} 0.5 grams) and water (3.78 {+-} 0.025 liters) to measured the absorbed dose delivered by a 12 Ci {sup 192}Ir HDR source. The fibers were held by a 7 x 7 cm{sup 2} template grid and optically connected to a 16-channel multianode photomultiplier tube (Hamamatsu, model H6568). Each pair consisted of one fiber 4 mm shorter than the other one to extract the dose by the subtraction method. A dose atlas was used for radiation delivered to the phantom. The plans followed delivered 5 and 7 Gy to a point located 2.0 centimeters away from the central dwelling positions. A total of 32 data points were acquired in a plan to assess the linearity and reproducibility of the measurements.Results: Reproducibility of the data was found to be within 5% and the overall accuracy of the system estimated to be {+-}5.5%. The linearity of the data for all 7 measureddose values (ranging from 0.6 to 7 Gy), gives a slope of 312 counts/Gy with a 1.4% relative deviation. Conclusion: This work indicates the possibility of measuring in real-time the dose effectively delivered to a biological system during prostate brachytherapy treatments. The availability of commercially thin (150 {micro}m) scintillating fibers opens the capability of using such system during clinical treatments (by embedding the fibers within the catheters) with the advantage of performing real-time adjustment of the dose delivery.

  8. [National primary standard of absorbed dose rate to water using a graphite calorimeter].

    PubMed

    Morishita, Yuichiro

    2013-01-01

    The calibration service in terms of absorbed dose to water started from 2011 after establishment of the national primary standard using a graphite calorimeter at the national metrology institute of Japan (NMIJ) and JCSS accreditation of the association for nuclear technology in medicine (ANTM). Accordingly, a new dosimetry protocol was introduced as JSMP12, in which details of the national standard were also described. This report presents a short review of the standard, a key comparison result, and a comparison result of calibration coefficients by JSMP01 and JSMP12.

  9. Estimates of radiation absorbed dose for intraperitoneally administered iodine-131 radiolabeled B72. 3 monoclonal antibody in patients with peritoneal carcinomatoses

    SciTech Connect

    Larson, S.M.; Carrasquillo, J.A.; Colcher, D.C.; Yokoyama, K.; Reynolds, J.C.; Bacharach, S.A.; Raubitchek, A.; Pace, L.; Finn, R.D.; Rotman, M. )

    1991-09-01

    Using a newly available model for determining estimates of radiation absorbed dose of radioisotopes administered intraperitoneally, the authors have calculated absorbed dose to tumor and normal tissues based on a surgically controlled study of radiolabeled antibody distribution. Ten patients with peritoneal carcinomatosis received intraperitoneal injections of the murine monoclonal antibody B72.3 radiolabeled with 131I. Biodistribution studies were performed using nuclear medicine methods until laparotomy at 4-14 days after injection. Surgical biopsies of normal tissues and tumor were obtained. The marrow was predicted to be the critical organ, with maximum tolerated dose (200 rad (2 Gy) to marrow) expected at about 200 mCi (7.4 GBq). In patients with large intraperitoneal tumor deposits, the tumor itself is an important source tissue for radiation exposure to normal tissues. Local hot-spots for tumor-absorbed dose were observed, with maximum tumor-absorbed dose calculated at 11,000 rad (11 Gy) per 100 mCi (3.7 GBq) administered intraperitoneal; however, tumor rad dose varied considerably. This may pose serious problems for curative therapy, especially in patients with large tumor burdens.

  10. Organ/Tissue absorbed doses measured with a human phantom torso in the 9th Shuttle-Mir Mission (STS-91).

    PubMed

    Yasuda, H; Komiyama, T; Fujitaka, K

    1999-09-01

    Organ/Tissue absorbed doses were measured with a life-size human phantom torso in the 9th Shuttle/Mir Mission (STS-91) from June 2 to 12, 1998. This is the first attempt to measure directly organ/tissue doses over a whole human body in space. The absorbed dose was measured by combination of two integrating detectors: thermo- luminescent dosemeter of Mg2SiO4: Tb (TDMS) and plastic nuclear track detector (PNTD). Both detectors were calibrated on ground using high-energy charged-particle beams. The detectors were packed in 59 cases of tissue-equivalent resin; and put into the positions of radiologically important organs and tissues in the phantom. Efficiency reductions of TDMS for high-LET particles were corrected based on the LET-differential particle fluence of space radiation measured with PNTDs. The accumulated absorbed doses during this 9.8-days mission at low-earth orbit (400 km x 51.6 degrees) ranged from 1.6 mGy at colon to 2.6 mGy at bone surface (shoulder) with a variation factor of 1.6. The absorbed doses at some internal organs were higher than the skin dose. This fact is important from the viewpoint of radiological protection for astronauts.

  11. Electrically tunable absorber based on nonstructured graphene

    NASA Astrophysics Data System (ADS)

    Ye, Caiyan; Zhu, Zhihong; Xu, Wei; Yuan, Xiaodong; Qin, Shiqiao

    2015-12-01

    We demonstrate numerically that a tunable absorber with absorption of 99.94% in the far infrared range can be obtained using a nonstructured graphene. The mechanism originates from a nonstructured graphene film supported on a periodical dielectric array that can show Fermi level modulation periodically and produce plasmonic resonances in the far infrared range. The nonstructured graphene can avoid the unexpected edge effects and does not influence the unique properties of graphene, which will be helpful in practice to achieve the unity absorption and facilitate the development of many related applications.

  12. Estimation of the absorbed dose in radiation-processed food. 4. EPR measurements on eggshell

    SciTech Connect

    Desrosiers, M.F.; Le, F.G. ); Harewood, P.M.; Josephson, E.S. ); Montesalvo, M. )

    1993-09-01

    Fresh whole eggs treated with ionizing radiation for Salmonellae control testing. The eggshell was then removed and examined by electron paramagnetic resonance (EPR) spectroscopy to determine if EPR could be used to (1) distinguish irradiated from unirradiated eggs and (2) assess the absorbed dose. No EPR signals were detected in unirradiated eggs, while strong signals were measurable for more than 200 days after irradiation. Although a number of EPR signals were measured, the most intense resonance (g = 2.0019) was used for dosimetry throughout the study. This signal was observed to increase linearly with dose (up to [approximately]6 kGy), which decayed [approximately]20% within the first 5 days after irradiation and remained relatively constant thereafter. The standard added-dose method was used to assess, retrospectively, the dose to eggs processed at 0.2, 0.7, and 1.4 kGy. Relatively good results were obtained when measurement was made on the day the shell was reirradiated; with this procedure estimates were better for shell processed at the lower doses.

  13. Simplified method for creating a density-absorbed dose calibration curve for the low dose range from Gafchromic EBT3 film.

    PubMed

    Gotanda, Tatsuhiro; Katsuda, Toshizo; Gotanda, Rumi; Kuwano, Tadao; Akagawa, Takuya; Tanki, Nobuyoshi; Tabuchi, Akihiko; Shimono, Tetsunori; Kawaji, Yasuyuki

    2016-01-01

    Radiochromic film dosimeters have a disadvantage in comparison with an ionization chamber in that the dosimetry process is time-consuming for creating a density-absorbed dose calibration curve. The purpose of this study was the development of a simplified method of creating a density-absorbed dose calibration curve from radiochromic film within a short time. This simplified method was performed using Gafchromic EBT3 film with a low energy dependence and step-shaped Al filter. The simplified method was compared with the standard method. The density-absorbed dose calibration curves created using the simplified and standard methods exhibited approximately similar straight lines, and the gradients of the density-absorbed dose calibration curves were -32.336 and -33.746, respectively. The simplified method can obtain calibration curves within a much shorter time compared to the standard method. It is considered that the simplified method for EBT3 film offers a more time-efficient means of determining the density-absorbed dose calibration curve within a low absorbed dose range such as the diagnostic range.

  14. Radiobiologic risk estimation from dental radiology. Part I. Absorbed doses to critical organs

    SciTech Connect

    Underhill, T.E.; Chilvarquer, I.; Kimura, K.; Langlais, R.P.; McDavid, W.D.; Preece, J.W.; Barnwell, G.

    1988-07-01

    The aim of the present study was to generate one consistent set of data for evaluating and comparing radiobiologic risks from different dental radiographic techniques. To accomplish this goal, absorbed doses were measured in fourteen anatomic sites from (1) five different panoramic machines with the use of rare-earth screens, (2) a twenty-film complete-mouth survey with E-speed film, long round cone, (3) a twenty-film complete-mouth survey with E-speed film, long rectangular cone, (4) a four-film interproximal survey with E-speed film, long round cone, and (5) a four-film interproximal survey with E-speed film, long rectangular cone. The dose to the thyroid gland, the active bone marrow, the brain, and the salivary glands was evaluated by means of exposure of a tissue-equivalent phantom, fitted with lithium fluoride thermoluminescent dosimeters (TLDs) at the relevant locations.

  15. Response functions for computing absorbed dose to skeletal tissues from photon irradiation.

    PubMed

    Eckerman, K F; Bolch, W E; Zankl, M; Petoussi-Henss, N

    2007-01-01

    The calculation of absorbed dose in skeletal tissues at radiogenic risk has been a difficult problem because the relevant structures cannot be represented in conventional geometric terms nor can they be visualised in the tomographic image data used to define the computational models of the human body. The active marrow, the tissue of concern in leukaemia induction, is present within the spongiosa regions of trabecular bone, whereas the osteoprogenitor cells at risk for bone cancer induction are considered to be within the soft tissues adjacent to the mineral surfaces. The International Commission on Radiological Protection (ICRP) recommends averaging the absorbed energy over the active marrow within the spongiosa and over the soft tissues within 10 microm of the mineral surface for leukaemia and bone cancer induction, respectively. In its forthcoming recommendation, it is expected that the latter guidance will be changed to include soft tissues within 50 microm of the mineral surfaces. To address the computational problems, the skeleton of the proposed ICRP reference computational phantom has been subdivided to identify those voxels associated with cortical shell, spongiosa and the medullary cavity of the long bones. It is further proposed that the Monte Carlo calculations with these phantoms compute the energy deposition in the skeletal target tissues as the product of the particle fluence in the skeletal subdivisions and applicable fluence-to-dose-response functions. This paper outlines the development of such response functions for photons.

  16. ESR spectroscopy for detecting gamma-irradiated dried vegetables and estimating absorbed doses

    NASA Astrophysics Data System (ADS)

    Kwon, Joong-Ho; Chung, Hyung-Wook; Byun, Myung-Woo

    2000-03-01

    In view of an increasing demand for food irradiation technology, the development of a reliable means of detection for the control of irradiated foods has become necessary. Various vegetable food materials (dried cabbage, carrot, chunggyungchae, garlic, onion, and green onion), which can be legally irradiated in Korea, were subjected to a detection study using ESR spectroscopy. Correlation coefficients ( R2) between absorbed doses (2.5-15 kGy) and their corresponding ESR signals were identified from ESR signals. Pre-established threshold values were successfully applied to the detection of 54 coded unknown samples of dried clean vegetables ( chunggyungchae, Brassica camestris var. chinensis), both non-irradiated and irradiated. The ESR signals of irradiated chunggyungchae decreased over a longer storage time, however, even after 6 months of ambient storage, these signals were still distinguishable from those of non-irradiated samples. The most successful estimates of absorbed dose (5 and 8 kGy) were obtained immediately after irradiation using a quadratic fit with average values of 4.85 and 8.65 kGy being calculated.

  17. Thyroid absorbed dose for people at Rongelap, Utirik, and Sifo on March 1, 1954

    SciTech Connect

    Lessard, E.T.; Miltenberger, R.P.; Conrad, R.A.; Musoline, S.V.; Naidu, J.R.; Moorthy, A.; Schopfer, C.J.

    1985-03-01

    A study was undertaken to reexamine thyroid absorbed dose estimates for people accidentally exposed to fallout at Rongelap, Sifo, and Utirik Islands from the Pacific weapon test known as Operation Castle BRAVO. The study included: (1) reevaluation of radiochemical analysis, to relate results from pooled urine to intake, retention, and excretion functions; (2) analysis of neutron-irradiation studies of archival soil samples, to estimate areal activities of the iodine isotopes; (3) analysis of source term, weather data, and meteorological functions used in predicting atmospheric diffusion and fallout deposition, to estimate airborne concentrations of the iodine isotopes; and (4) reevaluation of radioactive fallout, which contaminated a Japanese fishing vessel in the vicinity of Rongelap Island on March 1, 1954, to determine fallout components. The conclusions of the acute exposure study were that the population mean thyroid absorbed doses were 21 gray (2100 rad) at Rongelap, 6.7 gray (670 rad) at Sifo, and 2.8 gray (280 rad) at Utirik. The overall thyroid cancer risk we estimated was in agreement with results published on the Japanese exposed at Nagasaki and Hiroshima. We now postulate that the major route for intake of fallout was by direct ingestion of food prepared and consumed outdoors. 66 refs., 13 figs., 25 tabs.

  18. Secondary absorbed doses from light ion irradiation in anthropomorphic phantoms representing an adult male and a 10 year old child

    NASA Astrophysics Data System (ADS)

    Hultqvist, Martha; Gudowska, Irena

    2010-11-01

    Secondary organ absorbed doses were calculated by Monte Carlo simulations with the SHIELD-HIT07 code coupled with the mathematical anthropomorphic phantoms CHILD-HIT and ADAM-HIT. The simulated irradiations were performed with primary 1H, 4He, 7Li, 12C and 16O ion beams in the energy range 100-400 MeV/u which were directly impinging on the phantoms, i.e. approximating scanned beams, and with a simplified beamline for 12C irradiation. The evaluated absorbed doses to the out-of-field organs were in the range 10-6 to 10-1 mGy per target Gy and with standard deviations 0.5-20%. While the contribution to the organ absorbed doses from secondary neutrons dominated in the ion beams of low atomic number Z, the produced charged fragments and their subsequent charged secondaries of higher generations became increasingly important for the secondary dose delivery as Z of the primary ions increased. As compared to the simulated scanned 12C ion beam, the implementation of a simplified beamline for prostate irradiation with 12C ions resulted in an increase of 2-50 times in the organ absorbed doses depending on the distance from the target volume. Comparison of secondary organ absorbed doses delivered by 1H and 12C beams showed smaller differences when the RBE for local tumor control of the ions was considered and normalization to the RBE-weighted dose to the target was performed.

  19. Ultrathin microwave absorber based on metamaterial

    NASA Astrophysics Data System (ADS)

    Kim, Y. J.; Yoo, Y. J.; Hwang, J. S.; Lee, Y. P.

    2016-11-01

    We suggest that ultrathin broadband metamaterial is a perfect absorber in the microwave regime by utilizing the properties of a resistive sheet and metamaterial. Meta-atoms are composed of four-leaf clover-shape metallic patterns and a metal plane separated by three intermediate resistive sheet layers between four dielectric layers. We interpret the absorption mechanism of the broadband by using the distribution of surface currents at specific frequencies. The simulated absorption was over 99% in 1.8-4.2 GHz. The corresponding experimental absorption was also over 99% in 2.62-4.2 GHz; however, the absorption was slightly lower than 99% in 1.8-2.62 GHz because of the sheet resistance and the changed values for the dielectric constant. Furthermore, it is independent of incident angle. The results of this research indicate the possibility of applications, due to the suppression of noxious exposure, in cell phones, computers and microwave equipments.

  20. Tunable THz perfect absorber using graphene-based metamaterials

    NASA Astrophysics Data System (ADS)

    Faraji, Mahboobeh; Moravvej-Farshi, Mohammad Kazem; Yousefi, Leila

    2015-11-01

    A tunable THz absorber, with absorbance more than 90% is proposed, and numerically characterized. The absorber structure is based on metamaterials with unit cells consisting of two patterned graphene layers separated by a 5-nm thick layer of Al2O3. Numerical results show that when the chemical potential of the top graphene microribbons are tuned by an external variable bias and that of the lower graphene fishnet is kept at μC=0, frequency of the absorption peaks can be tuned as desired, therefore we can have a tunable or switchable absorber. The proposed absorber can have applications in designing tunable reflective THz filters or tunable THz switches and modulators. It can also be used for cloaking objects in THz range.

  1. [Development of the 60Co gamma-ray standard field for therapy-level dosimeter calibration in terms of absorbed dose to water (N(D,w))].

    PubMed

    Fukumura, Akifumi; Mizuno, Hideyuki; Fukahori, Mai; Sakata, Suoh

    2012-01-01

    A primary standard for the absorbed dose rate to water in a 60Co gamma-ray field was established at National Metrology Institute of Japan (NMIJ) in fiscal year 2011. Then, a 60Co gamma-ray standard field for therapy-level dosimeter calibration in terms of absorbed dose to water was developed at National Institute of Radiological Sciences (NIRS) as a secondary standard dosimetry laboratory (SSDL). The results of an IAEA/WHO TLD SSDL audit demonstrated that there was good agreement between NIRS stated absorbed dose to water and IAEA measurements. The IAEA guide based on the ISO standard was used to estimate the relative expanded uncertainty of the calibration factor for a therapy-level Farmer type ionization chamber in terms of absorbed dose to water (N(D,w)) with the new field. The uncertainty of N(D,w) was estimated to be 1.1% (k = 2), which corresponds to approximately one third of the value determined in the existing air kerma field. The dissemination of traceability of the calibration factor determined in the new field is expected to diminish the uncertainty of dose delivered to patients significantly.

  2. High-Dose 131I-Tositumomab (Anti-CD20) Radioimmunotherapy for Non-Hodgkin's Lymphoma: Adjusting Radiation Absorbed Dose to Actual Organ Volumes

    SciTech Connect

    Rajendran, Joseph G.; Fisher, Darrell R.; Gopal, A K.; Durack, L. D.; Press, O. W.; Eary, Janet F.

    2004-06-01

    Radioimmunotherapy (RIT) using 131I-tositumomab has been used successfully to treat relapsed or refractory B-cell non-Hodgin's lymphoma (NHL). Our approach to treatment planning has been to determine limits on radiation absorbed close to critical nonhematopoietic organs. This study demonstrates the feasibility of using CT to adjust for actual organ volumes in calculating organ-specific absorbed dose estimates. Methods: Records of 84 patients who underwent biodistribution studies after a trace-labeled infusion of 131I-tositumomab for RIT (January 1990 and April 2003) were reviewed. Serial planar -camera images and whole-body Nal probe counts were obtained to estimate 131I-antibody source-organ residence times as recommended by the MIRD Committee. The source-organ residence times for standard man or woman were adjusted by the ratio of the MIRD phantom organ mass to the CT-derived organ mass. Results: The mean radiation absorbed doses (in mGy/MBq) for our data using the MIRD model were lungs= 1.67; liver= 1.03; kidneys= 1.08; spleen= 2.67; and whole body= 0.3; and for CT volume-adjusted organ volumes (in mGy/MBq) were lungs= 1.30; liver= 0.92; kidneys= 0.76; spleen= 1.40; and whole body= 0.22. We determined the following correlation coefficients between the 2 methods for the various organs; lungs, 0.49; (P= 0.0001); liver, 0.64 (P= 0.004); kidneys, 0.45 (P= 0.0001), for the residence times. For therapy, patients received mean 131I administered activities of 19.2 GBq (520 mCi) after adjustment for CT-derived organ mass compared with 16.0 GBq (433 mCi) that would otherwise have been given had therapy been based only using standard MIRD organ volumes--a statistically significant difference (P= 0.0001). Conclusion: We observed large variations in organ masses among our patients. Our treatments were planned to deliver the maximally tolerated radiation dose to the dose-limiting normal organ. This work provides a simplified method for calculating patient-specific radiation

  3. Whole organ and islet of Langerhans dosimetry for calculation of absorbed doses resulting from imaging with radiolabeled exendin

    PubMed Central

    van der Kroon, Inge; Woliner-van der Weg, Wietske; Brom, Maarten; Joosten, Lieke; Frielink, Cathelijne; Konijnenberg, Mark W.; Visser, Eric P.; Gotthardt, Martin

    2017-01-01

    Radiolabeled exendin is used for non-invasive quantification of beta cells in the islets of Langerhans in vivo. High accumulation of radiolabeled exendin in the islets raised concerns about possible radiation-induced damage to these islets in man. In this work, islet absorbed doses resulting from exendin-imaging were calculated by combining whole organ dosimetry with small scale dosimetry for the islets. Our model contains the tissues with high accumulation of radiolabeled exendin: kidneys, pancreas and islets. As input for the model, data from a clinical study (radiolabeled exendin distribution in the human body) and from a preclinical study with Biobreeding Diabetes Prone (BBDP) rats (islet-to-exocrine uptake ratio, beta cell mass) were used. We simulated 111In-exendin and 68Ga-exendin absorbed doses in patients with differences in gender, islet size, beta cell mass and radiopharmaceutical uptake in the kidneys. In all simulated cases the islet absorbed dose was small, maximum 1.38 mGy for 68Ga and 66.0 mGy for 111In. The two sources mainly contributing to the islet absorbed dose are the kidneys (33–61%) and the islet self-dose (7.5–57%). In conclusion, all islet absorbed doses are low (<70 mGy), so even repeated imaging will hardly increase the risk on diabetes. PMID:28067253

  4. Metamaterial perfect absorber based on artificial dielectric "atoms".

    PubMed

    Liu, Xiaoming; Bi, Ke; Li, Bo; Zhao, Qian; Zhou, Ji

    2016-09-05

    In this work, we numerically designed and then experimentally verified a metamaterial perfect absorber based on artificial dielectric "atoms". This metamaterial absorber is composed of dielectric ceramic material (SrTiO3) "atoms" embedded in a background matrix on a metal plate. The dielectric "atoms" couple strongly to the incident electric and magnetic fields at the Mie resonance mode, leading to the narrow perfect absorption band with simulated and experimental absorptivities of 99% and 98.5% at 8.96 GHz, respectively. The designed metamaterial perfect absorber is polarization insensitive and can operate in wide angle incidence.

  5. Infrared perfect absorber based on nanowire metamaterial cavities.

    PubMed

    He, Yingran; Deng, Huixu; Jiao, Xiangyang; He, Sailing; Gao, Jie; Yang, Xiaodong

    2013-04-01

    An infrared perfect absorber based on a gold nanowire metamaterial cavities array on a gold ground plane is designed. The metamaterial made of gold nanowires embedded in an alumina host exhibits an effective permittivity with strong anisotropy, which supports cavity resonant modes of both electric dipole and magnetic dipole. The impedance of the cavity modes matches the incident plane wave in free space, leading to nearly perfect light absorption. The incident optical energy is efficiently converted into heat so that the local temperature of the absorber will increase. Results show that the designed absorber is polarization-insensitive and nearly omnidirectional for the incident angle.

  6. SU-E-CAMPUS-I-06: Y90 PET/CT for the Instantaneous Determination of Both Target and Non-Target Absorbed Doses Following Hepatic Radioembolization

    SciTech Connect

    Pasciak, A; Kao, J

    2014-06-15

    Purpose The process of converting Yttrium-90 (Y90) PET/CT images into 3D absorbed dose maps will be explained. The simple methods presented will allow the medical physicst to analyze Y90 PET images following radioembolization and determine the absorbed dose to tumor, normal liver parenchyma and other areas of interest, without application of Monte-Carlo radiation transport or dose-point-kernel (DPK) convolution. Methods Absorbed dose can be computed from Y90 PET/CT images based on the premise that radioembolization is a permanent implant with a constant relative activity distribution after infusion. Many Y90 PET/CT publications have used DPK convolution to obtain 3D absorbed dose maps. However, this method requires specialized software limiting clinical utility. The Local Deposition method, an alternative to DPK convolution, can be used to obtain absorbed dose and requires no additional computer processing. Pixel values from regions of interest drawn on Y90 PET/CT images can be converted to absorbed dose (Gy) by multiplication with a scalar constant. Results There is evidence that suggests the Local Deposition method may actually be more accurate than DPK convolution and it has been successfully used in a recent Y90 PET/CT publication. We have analytically compared dose-volume-histograms (DVH) for phantom hot-spheres to determine the difference between the DPK and Local Deposition methods, as a function of PET scanner point-spread-function for Y90. We have found that for PET/CT systems with a FWHM greater than 3.0 mm when imaging Y90, the Local Deposition Method provides a more accurate representation of DVH, regardless of target size than DPK convolution. Conclusion Using the Local Deposition Method, post-radioembolization Y90 PET/CT images can be transformed into 3D absorbed dose maps of the liver. An interventional radiologist or a Medical Physicist can perform this transformation in a clinical setting, allowing for rapid prediction of treatment efficacy by

  7. Contrast-enhanced radiotherapy: feasibility and characteristics of the physical absorbed dose distribution for deep-seated tumors

    NASA Astrophysics Data System (ADS)

    Garnica-Garza, H. M.

    2009-09-01

    Radiotherapy using kilovoltage x-rays in conjunction with contrast agents incorporated into the tumor, gold nanoparticles in particular, could represent a potential alternative to current techniques based on high-energy linear accelerators. In this paper, using the voxelized Zubal phantom in conjunction with the Monte Carlo code PENELOPE to model a prostate cancer treatment, it is shown that in combination with a 360° arc delivery technique, tumoricidal doses of radiation can be delivered to deep-seated tumors while still providing acceptable doses to the skin and other organs at risk for gold concentrations in the tumor within the range of 7-10 mg-Au per gram of tissue. Under these conditions and using a x-ray beam with 90% of the fluence within the range of 80-200 keV, a 72 Gy physical absorbed dose to the prostate can be delivered, while keeping the rectal wall, bladder, skin and femoral heads below 65 Gy, 55 Gy, 40 Gy and 30 Gy, respectively. However, it is also shown that non-uniformities in the contrast agent concentration lead to a severe degradation of the dose distribution and that, therefore, techniques to locally quantify the presence of the contrast agent would be necessary in order to determine the incident x-ray fluence that best reproduces the dosimetry obtained under conditions of uniform contrast agent distribution.

  8. Design of integration-ready metasurface-based infrared absorbers

    SciTech Connect

    Ogando, Karim Pastoriza, Hernán

    2015-07-28

    We introduce an integration ready design of metamaterial infrared absorber, highly compatible with many kinds of fabrication processes. We present the results of an exhaustive experimental characterization, including an analysis of the effects of single meta-atom geometrical parameters and collective arrangement. We confront the results with the theoretical interpretations proposed in the literature. Based on the results, we develop a set of practical design rules for metamaterial absorbers in the infrared region.

  9. Relative Importance of Hip and Sacral Pain Among Long-Term Gynecological Cancer Survivors Treated With Pelvic Radiotherapy and Their Relationships to Mean Absorbed Doses

    SciTech Connect

    Waldenstroem, Ann-Charlotte; Olsson, Caroline; Wilderaeng, Ulrica; Dunberger, Gail; Lind, Helena; Alevronta, Eleftheria; Al-Abany, Massoud; Tucker, Susan; Avall-Lundqvist, Elisabeth; Johansson, Karl-Axel; Steineck, Gunnar

    2012-10-01

    Purpose: To investigate the relative importance of patient-reported hip and sacral pain after pelvic radiotherapy (RT) for gynecological cancer and its relationship to the absorbed doses in these organs. Methods and Materials: We used data from a population-based study that included 650 long-term gynecological cancer survivors treated with pelvic RT in the Gothenburg and Stockholm areas in Sweden with a median follow-up of 6 years (range, 2-15) and 344 population controls. Symptoms were assessed through a study-specific postal questionnaire. We also analyzed the hip and sacral dose-volume histogram data for 358 of the survivors. Results: Of the survivors, one in three reported having or having had hip pain after completing RT. Daily pain when walking was four times as common among the survivors compared to controls. Symptoms increased in frequency with a mean absorbed dose >37.5 Gy. Also, two in five survivors reported pain in the sacrum. Sacral pain also affected their walking ability and tended to increase with a mean absorbed dose >42.5 Gy. Conclusions: Long-term survivors of gynecological cancer treated with pelvic RT experience hip and sacral pain when walking. The mean absorbed dose was significantly related to hip pain and was borderline significantly related to sacral pain. Keeping the total mean absorbed hip dose below 37.5 Gy during treatment might lower the occurrence of long-lasting pain. In relation to the controls, the survivors had a lower occurrence of pain and pain-related symptoms from the hips and sacrum compared with what has previously been reported for the pubic bone.

  10. Response functions for computing absorbed dose to skeletal tissues from neutron irradiation.

    PubMed

    Bahadori, Amir A; Johnson, Perry; Jokisch, Derek W; Eckerman, Keith F; Bolch, Wesley E

    2011-11-07

    Spongiosa in the adult human skeleton consists of three tissues-active marrow (AM), inactive marrow (IM) and trabecularized mineral bone (TB). AM is considered to be the target tissue for assessment of both long-term leukemia risk and acute marrow toxicity following radiation exposure. The total shallow marrow (TM(50)), defined as all tissues lying within the first 50 µm of the bone surfaces, is considered to be the radiation target tissue of relevance for radiogenic bone cancer induction. For irradiation by sources external to the body, kerma to homogeneous spongiosa has been used as a surrogate for absorbed dose to both of these tissues, as direct dose calculations are not possible using computational phantoms with homogenized spongiosa. Recent micro-CT imaging of a 40 year old male cadaver has allowed for the accurate modeling of the fine microscopic structure of spongiosa in many regions of the adult skeleton (Hough et al 2011 Phys. Med. Biol. 56 2309-46). This microstructure, along with associated masses and tissue compositions, was used to compute specific absorbed fraction (SAF) values for protons originating in axial and appendicular bone sites (Jokisch et al 2011 Phys. Med. Biol. 56 6857-72). These proton SAFs, bone masses, tissue compositions and proton production cross sections, were subsequently used to construct neutron dose-response functions (DRFs) for both AM and TM(50) targets in each bone of the reference adult male. Kerma conditions were assumed for other resultant charged particles. For comparison, AM, TM(50) and spongiosa kerma coefficients were also calculated. At low incident neutron energies, AM kerma coefficients for neutrons correlate well with values of the AM DRF, while total marrow (TM) kerma coefficients correlate well with values of the TM(50) DRF. At high incident neutron energies, all kerma coefficients and DRFs tend to converge as charged-particle equilibrium is established across the bone site. In the range of 10 eV to 100 Me

  11. Human absorbed dose calculations for iodine-131 and iodine-123 labeled meta-iodobenzyl-guanidine (mIBG): a potential myocardial and adrenal medulla imaging agent

    SciTech Connect

    Swanson, D.P.; Carey, J.E.; Brown, L.E.; Kline, R.C.; Wieland, D.M.; Thrall, J.H.; Beierwaltes, W.H.

    1981-06-01

    Tissue distribution studies with radiolabeled meta-iodobenzyl-guanidine (mIBG), an analog of the adrenergic neuronal blocking agent-guanethidine, suggest that this radiotracer may be useful for both myocardial imaging (labeled with I-123) and adrenal medulla imaging (labeled with I-131). Total body elimination was determined by whole body counting (well-type ionization chamber) of rats administered /sup 131/I-mIBG and time-activity tissue distribution data was obtained in dogs using /sup 125/I-mIBG. Using the MIRD formalism, researchers have estimated the human absorbed dose from /sup 131/I-mIBG, radionuclidically pure /sup 123/I-mIBG, and /sup 1/''/sup 3/I-mIBG contaminated with 4.8% /sup 125/I-mIBG (based on /sup 123/I radionuclidic purity specification of 1.4% I-125 at calibration). The largest absorbed dose from /sup 131/I-mIBG was delivered to the adrenals. For pure /sup 123/I-mIBG the largest absorbed dose was delivered to the thyroid (unblocked). The /sup 125/I contamination increased the absorbed dose to the adrenal medulla by a factor of 3.5.

  12. Measurement of absorbed dose-to-water for an HDR {sup 192}Ir source with ionization chambers in a sandwich setup

    SciTech Connect

    Araki, Fujio; Kouno, Tomohiro; Ohno, Takeshi; Kakei, Kiyotaka; Yoshiyama, Fumiaki; Kawamura, Shinji

    2013-09-15

    Purpose: In this study, a dedicated device for ion chamber measurements of absorbed dose-to-water for a Nucletron microSelectron-v2 HDR {sup 192}Ir brachytherapy source is presented. The device uses two ionization chambers in a so-called sandwich assembly. Using this setup and by taking the average reading of the two chambers, any dose error due to difficulties in absolute positioning (centering) of the source in between the chambers is cancelled to first order. The method's accuracy was examined by comparing measurements with absorbed dose-to-water determination based on the AAPM TG-43 protocol.Methods: The optimal source-to-chamber distance (SCD) for {sup 192}Ir dosimetry was determined from ion chamber measurements in a water phantom. The {sup 192}Ir source was sandwiched between two Exradin A1SL chambers (0.057 cm{sup 3}) at the optimal SCD separation. The measured ionization was converted to the absorbed dose-to-water using a {sup 60}Co calibration factor and a Monte Carlo-calculated beam quality conversion factor, k{sub Q}, for {sup 60}Co to {sup 192}Ir. An uncertainty estimate of the proposed method was determined based on reproducibility of measurements at different institutions for the same type of source.Results: The optimal distance for the A1SL chamber measurements was determined to be 5 cm from the {sup 192}Ir source center, considering the depth dependency of k{sub Q} for {sup 60}Co to {sup 192}Ir and the chamber positioning. The absorbed dose to water measured at (5 cm, 90°) on the transverse axis was 1.3% lower than TG-43 values and its reproducibility and overall uncertainty were 0.8% and 1.7%, respectively. The measurement doses at anisotropic points agreed within 1.5% with TG-43 values.Conclusions: The ion chamber measurement of absorbed dose-to-water with a sandwich method for the {sup 192}Ir source provides a more accurate, direct, and reference dose compared to the dose-to-water determination based on air-kerma strength in the TG-43 protocol

  13. Long-term stability of liquid ionization chambers with regard to their qualification as local reference dosimeters for low dose-rate absorbed dose measurements in water.

    PubMed

    Bahar-Gogani, J; Grindborg, J E; Johansson, B E; Wickman, G

    2001-03-01

    The long-term sensitivity and calibration stability of liquid ionization chambers (LICs) has been studied at a local and a secondary standards dosimetry laboratory over a period of 3 years. The chambers were transported several times by mail between the two laboratories for measurements. The LICs used in this work are designed for absorbed dose measurements in the dose rate region of 0.1-100 mGy min(-1) and have a liquid layer thickness of 1 mm and a sensitive volume of 16.2 mm3. The liquids used as sensitive media in the chambers are mixtures of isooctane (C8H18) and tetramethylsilane (Si(CH3)4) in different proportions (about 2 to 1). Operating at a polarizing voltage of 300 V the leakage current of the chambers was stable and never exceeded 3% of the observable current at a dose rate of about 1 mGy min(-1). The volume sensitivity of the chambers was measured to be of the order of 10(-9) C Gy(-1) mm3. No systematic changes in the absorbed dose to water calibration was observed for any of the chambers during the test period (sigma < 0.2%). Variations in chamber dose response with small changes in the polarizing voltage as well as sensitivity changes with accumulated absorbed dose were also investigated. Measurements showed that the LIC response varies by 0.15% per 1% change in applied voltage around 300 V. No significant change could be observed in the LIC sensitivity after a single absorbed dose of 15 kGy. The results indicate that the LIC can be made to serve as a calibration transfer instrument and a reference detector for absorbed dose to water determinations providing good precision and long-term reproducibility.

  14. Acoustic metamaterial structures based on multi-frequency vibration absorbers

    NASA Astrophysics Data System (ADS)

    Pai, P. Frank; Peng, Hao

    2014-03-01

    This paper presents a new metamaterial beam based on multi-frequency vibration absorbers for broadband vibration absorption. The proposed metamaterial beam consists of a uniform isotropic beam and small two-mass spring-mass- damper subsystems at many locations along the beam to act as multi-frequency vibration absorbers. For an infinite metamaterial beam, governing equations of a unit cell are derived using the extended Hamilton principle. The existence of two stopbands is demonstrated using a model based on averaging material properties over a cell length and a model based on finite element modeling and the Bloch-Floquet theory for periodic structures. For a finite metamaterial beam, because these two idealized models cannot be used for finite beams and/or elastic waves having short wavelengths, a finite-element method is used for detailed modeling and analysis. The concepts of negative effective mass and effective stiffness and how the spring-mass-damper subsystem creates two stopbands are explained in detail. Numerical simulations reveal that the actual working mechanism of the proposed metamaterial beam is based on the concept of conventional mechanical vibration absorbers. For an incoming wave with a frequency in one of the two stopbands, the absorbers are excited to vibrate in their optical modes to create shear forces to straighten the beam and stop the wave propagation. For an incoming wave with a frequency outside of but between the two stopbands, it can be efficiently damped out by the damper with the second mass of each absorber. Hence, the two stopbands are connected into a wide stopband. Numerical examples validate the concept and show that the structure's boundary conditions do not have significant influence on the absorption of high-frequency waves. However, for absorption of low-frequency waves, the structure's boundary conditions and resonance frequencies and the location and spatial distribution of absorbers need to be considered in design, and it

  15. Monte Carlo Analysis of Pion Contribution to Absorbed Dose from Galactic Cosmic Rays

    NASA Technical Reports Server (NTRS)

    Aghara, S.K.; Battnig, S.R.; Norbury, J.W.; Singleterry, R.C.

    2009-01-01

    Accurate knowledge of the physics of interaction, particle production and transport is necessary to estimate the radiation damage to equipment used on spacecraft and the biological effects of space radiation. For long duration astronaut missions, both on the International Space Station and the planned manned missions to Moon and Mars, the shielding strategy must include a comprehensive knowledge of the secondary radiation environment. The distribution of absorbed dose and dose equivalent is a function of the type, energy and population of these secondary products. Galactic cosmic rays (GCR) comprised of protons and heavier nuclei have energies from a few MeV per nucleon to the ZeV region, with the spectra reaching flux maxima in the hundreds of MeV range. Therefore, the MeV - GeV region is most important for space radiation. Coincidentally, the pion production energy threshold is about 280 MeV. The question naturally arises as to how important these particles are with respect to space radiation problems. The space radiation transport code, HZETRN (High charge (Z) and Energy TRaNsport), currently used by NASA, performs neutron, proton and heavy ion transport explicitly, but it does not take into account the production and transport of mesons, photons and leptons. In this paper, we present results from the Monte Carlo code MCNPX (Monte Carlo N-Particle eXtended), showing the effect of leptons and mesons when they are produced and transported in a GCR environment.

  16. Boundary Electron and Beta Dosimetry-Quantification of the Effects of Dissimilar Media on Absorbed Dose

    NASA Astrophysics Data System (ADS)

    Nunes, Josane C.

    1991-02-01

    This work quantifies the changes effected in electron absorbed dose to a soft-tissue equivalent medium when part of this medium is replaced by a material that is not soft -tissue equivalent. That is, heterogeneous dosimetry is addressed. Radionuclides which emit beta particles are the electron sources of primary interest. They are used in brachytherapy and in nuclear medicine: for example, beta -ray applicators made with strontium-90 are employed in certain ophthalmic treatments and iodine-131 is used to test thyroid function. More recent medical procedures under development and which involve beta radionuclides include radioimmunotherapy and radiation synovectomy; the first is a cancer modality and the second deals with the treatment of rheumatoid arthritis. In addition, the possibility of skin surface contamination exists whenever there is handling of radioactive material. Determination of absorbed doses in the examples of the preceding paragraph requires considering boundaries of interfaces. Whilst the Monte Carlo method can be applied to boundary calculations, for routine work such as in clinical situations, or in other circumstances where doses need to be determined quickly, analytical dosimetry would be invaluable. Unfortunately, few analytical methods for boundary beta dosimetry exist. Furthermore, the accuracy of results from both Monte Carlo and analytical methods has to be assessed. Although restricted to one radionuclide, phosphorus -32, the experimental data obtained in this work serve several purposes, one of which is to provide standards against which calculated results can be tested. The experimental data also contribute to the relatively sparse set of published boundary dosimetry data. At the same time, they may be useful in developing analytical boundary dosimetry methodology. The first application of the experimental data is demonstrated. Results from two Monte Carlo codes and two analytical methods, which were developed elsewhere, are compared

  17. Verification of absorbed dose rates in reference beta radiation fields: Measurements with an extrapolation chamber and radiochromic film.

    PubMed

    Reynaldo, S R; Benavente, J A; Da Silva, T A

    2016-11-01

    Beta Secondary Standard 2 (BSS 2) provides beta radiation fields with certified values of absorbed dose to tissue and the derived operational radiation protection quantities. As part of the quality assurance, the reliability of the CDTN BSS2 system was verified through measurements in the (90)Sr/(90)Y and (85)Kr beta radiation fields. Absorbed dose rates and their angular variation were measured with a 23392 model PTW extrapolation chamber and with Gafchromic radiochromic films on a PMMA slab phantom. The feasibility of using both methods was analyzed.

  18. Transcriptional Response in Mouse Thyroid Tissue after 211At Administration: Effects of Absorbed Dose, Initial Dose-Rate and Time after Administration

    PubMed Central

    Rudqvist, Nils; Spetz, Johan; Schüler, Emil; Parris, Toshima Z.; Langen, Britta; Helou, Khalil; Forssell-Aronsson, Eva

    2015-01-01

    Background 211At-labeled radiopharmaceuticals are potentially useful for tumor therapy. However, a limitation has been the preferential accumulation of released 211At in the thyroid gland, which is a critical organ for such therapy. The aim of this study was to determine the effect of absorbed dose, dose-rate, and time after 211At exposure on genome-wide transcriptional expression in mouse thyroid gland. Methods BALB/c mice were i.v. injected with 1.7, 7.5 or 100 kBq 211At. Animals injected with 1.7 kBq were killed after 1, 6, or 168 h with mean thyroid absorbed doses of 0.023, 0.32, and 1.8 Gy, respectively. Animals injected with 7.5 and 100 kBq were killed after 6 and 1 h, respectively; mean thyroid absorbed dose was 1.4 Gy. Total RNA was extracted from pooled thyroids and the Illumina RNA microarray platform was used to determine mRNA levels. Differentially expressed transcripts and enriched GO terms were determined with adjusted p-value <0.01 and fold change >1.5, and p-value <0.05, respectively. Results In total, 1232 differentially expressed transcripts were detected after 211At administration, demonstrating a profound effect on gene regulation. The number of regulated transcripts increased with higher initial dose-rate/absorbed dose at 1 or 6 h. However, the number of regulated transcripts decreased with mean absorbed dose/time after 1.7 kBq 211At administration. Furthermore, similar regulation profiles were seen for groups administered 1.7 kBq. Interestingly, few previously proposed radiation responsive genes were detected in the present study. Regulation of immunological processes were prevalent at 1, 6, and 168 h after 1.7 kBq administration (0.023, 0.32, 1.8 Gy). PMID:26177204

  19. Assessment of the Absorbed Dose in the Kidney of Nuclear Nephrology Paediatric Patients using ICRP Biokinetic Data and Monte Carlo Simulations with Mass-Scaled Paediatric Voxel Phantoms.

    PubMed

    Teles, P; Mendes, M; Zankl, M; de Sousa, V; Santos, A I; Vaz, P

    2016-04-21

    The aim of this work is to use Monte Carlo simulations and VOXEL phantoms to estimate the absorbed dose in paediatric patients (aged from 2 weeks to 16 y), with normal renal function, to whom technetium-99m-dimercaptosuccinic acid ((99m)Tc-DMSA) was administered, for diagnostic renal scintigraphy purposes; and compare them with values obtained using the International Commission on Radiological Protection (ICRP) methodology. In the ICRP methodology, the cumulated absorbed dose in the kidneys is estimated by multiplying the administered activity with the corresponding given dose coefficients. The other methods were based on Monte Carlo simulations performed on two paediatric voxel phantoms ( ITALIC! CHILDand ITALIC! BABY), and another three phantoms, which were modified to suit the mass of the patients' kidneys, and other anatomical factors. Different ITALIC! S-values were estimated using this methodology, which together with solving the ICRP biokinetic model to determine the cumulated activities, allowed for the estimation of absorbed doses different from those obtained with the ICRP method, together with new dose coefficients. The obtained values were then compared. The deviations suggest that the ITALIC! S-values are strongly dependent on the patient's total body weight, which could be in contrast with the ICRP data, which is provided by age, regardless of other anatomical parameters.

  20. Direct measurement of absorbed dose to water in HDR {sup 192}Ir brachytherapy: Water calorimetry, ionization chamber, Gafchromic film, and TG-43

    SciTech Connect

    Sarfehnia, Arman; Kawrakow, Iwan; Seuntjens, Jan

    2010-04-15

    Purpose: Gafchromic film and ionometric calibration procedures for HDR {sup 192}Ir brachytherapy sources in terms of dose rate to water are presented and the experimental results are compared to the TG-43 protocol as well as with the absolute dose measurement results from a water calorimetry-based primary standard. Methods: EBT-1 Gafchromic films, an A1SL Exradin miniature Shonka thimble type chamber, and an SI HDR 1000 Plus well-type chamber (Standard Imaging, Inc., Middleton, WI) with an ADCL traceable S{sub k} calibration coefficient (following the AAPM TG-43 protocol) were used. The Farmer chamber and Gafchromic film measurements were performed directly in water. All results were compared to direct and absolute absorbed dose to water measurements from a 4 deg. C stagnant water calorimeter. Results: Based on water calorimetry, the authors measured the dose rate to water to be 361{+-}7 {mu}Gy/(h U) at a 55 mm source-to-detector separation. The dose rate normalized to air-kerma strength for all the techniques agree with the water calorimetry results to within 0.83%. The overall 1-sigma uncertainty on water calorimetry, ionization chamber, Gafchromic film, and TG-43 dose rate measurement amounts to 1.90%, 1.44%, 1.78%, and 2.50%, respectively. Conclusions: This work allows us to build a more realistic uncertainty estimate for absorbed dose to water determination using the TG-43 protocol. Furthermore, it provides the framework necessary for a shift from indirect HDR {sup 192}Ir brachytherapy dosimetry to a more accurate, direct, and absolute measurement of absorbed dose to water.

  1. Analysis of the Body Distribution of Absorbed Dose in the Organs of Three Species of Fish from Sepetiba Bay

    NASA Astrophysics Data System (ADS)

    Pereira, Wagner de S.; Kelecom, Alphonse; dos Santos Gouvea, Rita de Cássia; Py Júnior, Delcy de Azevedo

    2008-08-01

    The body distribution of Polonium-210 in three fishes from the Sepetiba Bay (Macrodon ancylodon, Micropogonias furnieri and Mugil curema) has been studied under the approach of the Department of Energy of the United States of America (DOE) that set the limit of absorbed dose rate in biota equal to 3.5×103 μGy/y, and that also established the relation between dose rate (D) and radionuclide concentration (c) on a fish muscle fresh weight basis, as follows: D = 5.05 E×N×C, assuming that the radionuclide distribution is homogenous among organs. Two hypotheses were tested here, using statistical tools: 1) is the body distribution of absorbed dose homogenous among organs? and 2) is the body distribution of absorbed dose identical among studied fishes? It was concluded, as expected, that the distribution among organs is heterogeneous; but, unexpectedly, that the three fishes display identical body distribution pattern, although they belong to different trophic levels. Hence, concerning absorbed dose calculation, the statement that data distribution is homogenous must be understood merely as an approximation, at least in the case of Polonium-210.

  2. Analysis of the Body Distribution of Absorbed Dose in the Organs of Three Species of Fish from Sepetiba Bay

    SciTech Connect

    Pereira, Wagner de S; Kelecom, Alphonse; Santos Gouvea, Rita de Cassia dos; Azevedo Py Junior, Delcy de

    2008-08-07

    The body distribution of Polonium-210 in three fishes from the Sepetiba Bay (Macrodon ancylodon, Micropogonias furnieri and Mugil curema) has been studied under the approach of the Department of Energy of the United States of America (DOE) that set the limit of absorbed dose rate in biota equal to 3.5x10{sup 3} {mu}Gy/y, and that also established the relation between dose rate (D) and radionuclide concentration (c) on a fish muscle fresh weight basis, as follows: D = 5.05 ExNxC, assuming that the radionuclide distribution is homogenous among organs. Two hypotheses were tested here, using statistical tools: 1) is the body distribution of absorbed dose homogenous among organs? and 2) is the body distribution of absorbed dose identical among studied fishes? It was concluded, as expected, that the distribution among organs is heterogeneous; but, unexpectedly, that the three fishes display identical body distribution pattern, although they belong to different trophic levels. Hence, concerning absorbed dose calculation, the statement that data distribution is homogenous must be understood merely as an approximation, at least in the case of Polonium-210.

  3. Influence of the electron energy and number of beams on the absorbed dose distributions in radiotherapy of deep seated targets.

    PubMed

    Garnica-Garza, H M

    2014-12-01

    With the advent of compact laser-based electron accelerators, there has been some renewed interest on the use of such charged particles for radiotherapy purposes. Traditionally, electrons have been used for the treatment of fairly superficial lesions located at depths of no more than 4cm inside the patient, but lately it has been proposed that by using very high energy electrons, i.e. those with an energy in the order of 200-250MeV it should be possible to safely reach deeper targets. In this paper, we used a realistic patient model coupled with detailed Monte Carlo simulations of the electron transport in such a patient model to examine the characteristics of the resultant absorbed dose distributions as a function of both the electron beam energy as well as the number of beams for a particular type of treatment, namely, a prostate radiotherapy treatment. Each treatment is modeled as consisting of nine, five or three beam ports isocentrically distributed around the patient. An optimization algorithm is then applied to obtain the beam weights in each treatment plan. It is shown that for this particularly challenging case, both excellent target coverage and critical structure sparing can be obtained for energies in the order of 150MeV and for as few as three treatment ports, while significantly reducing the total energy absorbed by the patient with respect to a conventional megavoltage x-ray treatment.

  4. A 3D Monte Carlo Method for Estimation of Patient-specific Internal Organs Absorbed Dose for 99mTc-hynic-Tyr3-octreotide Imaging

    PubMed Central

    Momennezhad, Mehdi; Nasseri, Shahrokh; Zakavi, Seyed Rasoul; Parach, Ali Asghar; Ghorbani, Mahdi; Asl, Ruhollah Ghahraman

    2016-01-01

    Single-photon emission computed tomography (SPECT)-based tracers are easily available and more widely used than positron emission tomography (PET)-based tracers, and SPECT imaging still remains the most prevalent nuclear medicine imaging modality worldwide. The aim of this study is to implement an image-based Monte Carlo method for patient-specific three-dimensional (3D) absorbed dose calculation in patients after injection of 99mTc-hydrazinonicotinamide (hynic)-Tyr3-octreotide as a SPECT radiotracer. 99mTc patient-specific S values and the absorbed doses were calculated with GATE code for each source-target organ pair in four patients who were imaged for suspected neuroendocrine tumors. Each patient underwent multiple whole-body planar scans as well as SPECT imaging over a period of 1-24 h after intravenous injection of 99mhynic-Tyr3-octreotide. The patient-specific S values calculated by GATE Monte Carlo code and the corresponding S values obtained by MIRDOSE program differed within 4.3% on an average for self-irradiation, and differed within 69.6% on an average for cross-irradiation. However, the agreement between total organ doses calculated by GATE code and MIRDOSE program for all patients was reasonably well (percentage difference was about 4.6% on an average). Normal and tumor absorbed doses calculated with GATE were slightly higher than those calculated with MIRDOSE program. The average ratio of GATE absorbed doses to MIRDOSE was 1.07 ± 0.11 (ranging from 0.94 to 1.36). According to the results, it is proposed that when cross-organ irradiation is dominant, a comprehensive approach such as GATE Monte Carlo dosimetry be used since it provides more reliable dosimetric results. PMID:27134562

  5. A 3D Monte Carlo Method for Estimation of Patient-specific Internal Organs Absorbed Dose for (99m)Tc-hynic-Tyr(3)-octreotide Imaging.

    PubMed

    Momennezhad, Mehdi; Nasseri, Shahrokh; Zakavi, Seyed Rasoul; Parach, Ali Asghar; Ghorbani, Mahdi; Asl, Ruhollah Ghahraman

    2016-01-01

    Single-photon emission computed tomography (SPECT)-based tracers are easily available and more widely used than positron emission tomography (PET)-based tracers, and SPECT imaging still remains the most prevalent nuclear medicine imaging modality worldwide. The aim of this study is to implement an image-based Monte Carlo method for patient-specific three-dimensional (3D) absorbed dose calculation in patients after injection of (99m)Tc-hydrazinonicotinamide (hynic)-Tyr(3)-octreotide as a SPECT radiotracer. (99m)Tc patient-specific S values and the absorbed doses were calculated with GATE code for each source-target organ pair in four patients who were imaged for suspected neuroendocrine tumors. Each patient underwent multiple whole-body planar scans as well as SPECT imaging over a period of 1-24 h after intravenous injection of (99m)hynic-Tyr(3)-octreotide. The patient-specific S values calculated by GATE Monte Carlo code and the corresponding S values obtained by MIRDOSE program differed within 4.3% on an average for self-irradiation, and differed within 69.6% on an average for cross-irradiation. However, the agreement between total organ doses calculated by GATE code and MIRDOSE program for all patients was reasonably well (percentage difference was about 4.6% on an average). Normal and tumor absorbed doses calculated with GATE were slightly higher than those calculated with MIRDOSE program. The average ratio of GATE absorbed doses to MIRDOSE was 1.07 ± 0.11 (ranging from 0.94 to 1.36). According to the results, it is proposed that when cross-organ irradiation is dominant, a comprehensive approach such as GATE Monte Carlo dosimetry be used since it provides more reliable dosimetric results.

  6. Deuterons at energies of 10 MeV to 1 TeV: conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C.

    PubMed

    Copeland, Kyle; Parker, Donald E; Friedberg, Wallace

    2011-01-01

    Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent for isotropic exposure of an adult female and an adult male to deuterons ((2)H(+)) in the energy range 10 MeV-1 TeV (0.01-1000 GeV). Coefficients were calculated using the Monte Carlo transport code MCNPX 2.7.C and BodyBuilder™ 1.3 anthropomorphic phantoms. Phantoms were modified to allow calculation of the effective dose to a Reference Person using tissues and tissue weighting factors from 1990 and 2007 recommendations of the International Commission on Radiological Protection (ICRP) and gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. Coefficients for the equivalent and effective dose incorporated a radiation weighting factor of 2. At 15 of 19 energies for which coefficients for the effective dose were calculated, coefficients based on ICRP 1990 and 2007 recommendations differed by <3%. The greatest difference, 47%, occurred at 30 MeV.

  7. Acoustic metamaterial panels based on multi frequency vibration absorbers

    NASA Astrophysics Data System (ADS)

    Shi, Chao; Sun, Hongwei; Hu, Xiaolei; Gu, Jinliang

    2016-04-01

    Presented here is a new metamaterial panel based on multi-frequency vibration absorbers for broadband vibration absorption. The proposed metamaterial panel consists of a uniform isotropic panel and small two-mass spring-mass-damper subsystem many locations along the panel to act as multi-frequency vibration absorbers. The existence of two stopbands is demonstrated using a model based on averaging material properties over a cell length and a model based on finite element modeling and the Bloch-Floquet theory for periodic structures. For a finite metamaterial panel, because these two idealized models can not be used for finite panels and/or elastic waves having short wavelengths, a finite-element method is used for detailed modeling and analysis. The concepts of negative effective stiffness is explained in detail. For an incoming wave with a frequency in one of the two stopbands, the absorbers are excited to vibrate in their optical modes to create shear forces to straighten the panel and stop the wave propagation. For an incoming wave with a frequency outside of but between the two stopbands, it can be efficiently damped out by the damper with these mass of each absorber. Hence, the two stopbands are connected in to a wide stopband. Numerical examples validate the concept and show that the structures boundary conditions do not have significant influence on the absorption of high-frequency waves. However, for absorption of low-frequency waves, the structures boundary conditions and resonance frequencies and the location and spatial distribution of absorbers need to be considered in design, and it is better to use heavier masses for absorbers.

  8. Absorbed dose measurements of a handheld 50 kVP X-ray source in water with thermoluminescence dosemeters.

    PubMed

    Soares, Christopher; Drupieski, Chris; Wingert, Brian; Pritchett, Garey; Pagonis, Vasilis; O'Brien, Michelle; Sliski, Alan; Bilski, Pawel; Olko, Pawel

    2006-01-01

    Absorbed dose rate measurements of a 50 kV(p) handheld X-ray probe source in a water phantom are described. The X-ray generator is capable of currents of up to 40 microA, and is designed for cranial brachytherapy and intraoperative applications with applicators. The measurements were performed in a computer-controlled water phantom in which both the source and the detectors are mounted. Two different LiF thermoluminescence dosemeter (TLD) phosphors were employed for the measurements, MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P). Two small ionisation chambers (0.02 and 0.0053 cm(3)) were also employed. The TLDs and chambers were positioned in watertight mounts made of water-equivalent plastic. The chambers were calibrated in terms of air-kerma rate, and conventional protocols were used to convert the measurements to absorbed dose rate. The TLDs were calibrated at National Institute of Standards and Technology (NIST) in terms of absorbed dose rate using a (60)Co teletherapy beam and narrow-spectrum X-ray beams. For the latter, absorbed dose was inferred from air-kerma rate using calculated air-kerma-to-dose conversion factors. The reference points of the various detectors were taken as the center of the TLD volumes and the entrance windows of the ionisation chambers. Measurements were made at distances of 3-45 mm from the detector reference point to the source center. In addition, energy dependence of response measurements of the TLDs used was made using NIST reference narrow spectrum X-ray beams. Measurement results showed reasonable agreement in absorbed dose rate determined from the energy dependence corrected TLD readings and from the ionisation chambers. Volume averaging effects of the TLDs at very close distances to the source were also evident.

  9. Frequency-tunable terahertz absorbers based on graphene metasurface

    NASA Astrophysics Data System (ADS)

    Chen, Ming; Sun, Wei; Cai, Jianjin; Chang, Linzi; Xiao, Xiaofei

    2017-01-01

    We present efficient designs of graphene-based thin absorbers, which are capable of near-unity absorption of the incident electromagnetic waves in the terahertz regime. Primarily, a single-frequency absorber is proposed. Subsequently, by simply stacking the double layer graphene metasurface with various geometric dimensions, the dual-frequency absorption and broadband absorption are realized respectively. Results demonstrate that the absorptivity of the single-frequency absorber reaches 99.51% at 2.71 THz when the Fermi energy is fixed at 0.9 eV. The dual-frequency absorber can simultaneously work at two frequencies with its absorptivity being 98.94% for 1.99 THz and 99.1% for 2.69 THz. The bandwidth of absorption rate above 90% expands three times when compared with the former single-frequency absorber. Additionally, it possesses the polarization-insensitive and large angle tolerance properties. More importantly, the absorption frequency can be dynamically controlled by adjusting Fermi energy levels without varying the nanostructure, which exhibits tremendous application values in many fields.

  10. Dual band metamaterial perfect absorber based on Mie resonances

    NASA Astrophysics Data System (ADS)

    Liu, Xiaoming; Lan, Chuwen; Bi, Ke; Li, Bo; Zhao, Qian; Zhou, Ji

    2016-08-01

    We numerically and experimentally demonstrated a polarization insensitive dual-band metamaterial perfect absorber working in wide incident angles based on the two magnetic Mie resonances of a single dielectric "atom" with simple structure. Two absorption bands with simulated absorptivity of 99% and 96%, experimental absorptivity of 97% and 94% at 8.45 and 11.97 GHz were achieved due to the simultaneous magnetic and electric resonances in dielectric "atom" and copper plate. Mie resonances of dielectric "atom" provide a simple way to design metamaterial perfect absorbers with high symmetry.

  11. Absorbed dose evaluation of Auger electron-emitting radionuclides: impact of input decay spectra on dose point kernels and S-values

    NASA Astrophysics Data System (ADS)

    Falzone, Nadia; Lee, Boon Q.; Fernández-Varea, José M.; Kartsonaki, Christiana; Stuchbery, Andrew E.; Kibédi, Tibor; Vallis, Katherine A.

    2017-03-01

    The aim of this study was to investigate the impact of decay data provided by the newly developed stochastic atomic relaxation model BrIccEmis on dose point kernels (DPKs - radial dose distribution around a unit point source) and S-values (absorbed dose per unit cumulated activity) of 14 Auger electron (AE) emitting radionuclides, namely 67Ga, 80mBr, 89Zr, 90Nb, 99mTc, 111In, 117mSn, 119Sb, 123I, 124I, 125I, 135La, 195mPt and 201Tl. Radiation spectra were based on the nuclear decay data from the medical internal radiation dose (MIRD) RADTABS program and the BrIccEmis code, assuming both an isolated-atom and condensed-phase approach. DPKs were simulated with the PENELOPE Monte Carlo (MC) code using event-by-event electron and photon transport. S-values for concentric spherical cells of various sizes were derived from these DPKs using appropriate geometric reduction factors. The number of Auger and Coster–Kronig (CK) electrons and x-ray photons released per nuclear decay (yield) from MIRD-RADTABS were consistently higher than those calculated using BrIccEmis. DPKs for the electron spectra from BrIccEmis were considerably different from MIRD-RADTABS in the first few hundred nanometres from a point source where most of the Auger electrons are stopped. S-values were, however, not significantly impacted as the differences in DPKs in the sub-micrometre dimension were quickly diminished in larger dimensions. Overestimation in the total AE energy output by MIRD-RADTABS leads to higher predicted energy deposition by AE emitting radionuclides, especially in the immediate vicinity of the decaying radionuclides. This should be taken into account when MIRD-RADTABS data are used to simulate biological damage at nanoscale dimensions.

  12. Absorbed dose evaluation of Auger electron-emitting radionuclides: impact of input decay spectra on dose point kernels and S-values.

    PubMed

    Falzone, Nadia; Lee, Boon Q; Fernández-Varea, José M; Kartsonaki, Christiana; Stuchbery, Andrew E; Kibédi, Tibor; Vallis, Katherine A

    2017-03-21

    The aim of this study was to investigate the impact of decay data provided by the newly developed stochastic atomic relaxation model BrIccEmis on dose point kernels (DPKs - radial dose distribution around a unit point source) and S-values (absorbed dose per unit cumulated activity) of 14 Auger electron (AE) emitting radionuclides, namely (67)Ga, (80m)Br, (89)Zr, (90)Nb, (99m)Tc, (111)In, (117m)Sn, (119)Sb, (123)I, (124)I, (125)I, (135)La, (195m)Pt and (201)Tl. Radiation spectra were based on the nuclear decay data from the medical internal radiation dose (MIRD) RADTABS program and the BrIccEmis code, assuming both an isolated-atom and condensed-phase approach. DPKs were simulated with the PENELOPE Monte Carlo (MC) code using event-by-event electron and photon transport. S-values for concentric spherical cells of various sizes were derived from these DPKs using appropriate geometric reduction factors. The number of Auger and Coster-Kronig (CK) electrons and x-ray photons released per nuclear decay (yield) from MIRD-RADTABS were consistently higher than those calculated using BrIccEmis. DPKs for the electron spectra from BrIccEmis were considerably different from MIRD-RADTABS in the first few hundred nanometres from a point source where most of the Auger electrons are stopped. S-values were, however, not significantly impacted as the differences in DPKs in the sub-micrometre dimension were quickly diminished in larger dimensions. Overestimation in the total AE energy output by MIRD-RADTABS leads to higher predicted energy deposition by AE emitting radionuclides, especially in the immediate vicinity of the decaying radionuclides. This should be taken into account when MIRD-RADTABS data are used to simulate biological damage at nanoscale dimensions.

  13. Dose esclation in radioimmunotherapy based on projected whole body dose

    SciTech Connect

    Wahl, R.L.; Kaminski, M.S.; Regan, D.

    1994-05-01

    A variety of approaches have been utilized in conducting phase I radioimmunotherapy dose-escalation trials. Escalation of dose has been based on graded increases in administered mCi; mCi/kg; or mCi/m2. It is also possible to escalate dose based on tracer-projected marrow, blood or whole body radiation dose. We describe our results in performing a dose-escalation trial in patients with non-Hodgkin lymphoma based on escalating administered whole-body radiation dose. The mCi dose administered was based on a patient-individualized tracer projected whole-body dose. 25 patients were entered on the study. RIT with 131 I anti-B-1 was administered to 19 patients. The administered dose was prescribed based on the projected whole body dose, determined from patient-individualized tracer studies performed prior to RIT. Whole body dose estimates were based on the assumption that the patient was an ellipsoid, with 131 antibody kinetics determined using a whole-body probe device acquiring daily conjugate views of 1 minute duration/view. Dose escalation levels proceeded with 10 cGy increments from 25 cGy whole-body and continues, now at 75 cGy. The correlation among potential methods of dose escalation and toxicity was assessed. Whole body radiation dose by probe was strongly correlated with the blood radiation dose determined from sequential blood sampling during tracer studies (r=.87). Blood radiation dose was very weakly correlated with mCi dose (r=.4) and mCi/kg (r=.45). Whole body radiation dose appeared less well-correlated with injected dose in mCi (r=.6), or mCi/kg (r=.64). Toxicity has been infrequent in these patients, but appears related to increasing whole body dose. Non-invasive determination of whole-body radiation dose by gamma probe represents a non-invasive method of estimating blood radiation dose, and thus of estimating bone marrow radiation dose.

  14. Absorbed Dose Rate Due to Intake of Natural Radionuclides by Tilapia Fish (Tilapia nilotica,Linnaeus, 1758) Estimated Near Uranium Mining at Caetite, Bahia, Brazil

    SciTech Connect

    Pereira, Wagner de S; Kelecom, Alphonse

    2008-08-07

    The uranium mining at Caetite (Uranium Concentrate Unit--URA) is in its operational phase. Aiming to estimate the radiological environmental impact of the URA, a monitoring program is underway. In order to preserve the biota of the deleterious effects from radiation and to act in a pro-active way as expected from a licensing body, the present work aims to use an environmental protection methodology based on the calculation of absorbed dose rate in biota. Thus, selected target organism was the Tilapia fish (Tilapia nilotica, Linnaeus, 1758) and the radionuclides were: uranium (U-238), thorium (Th-232), radium (Ra-226 and Ra-228) and lead (Pb-210). As, in Brazil there are no radiation exposure limits adopted for biota the value proposed by the Department of Energy (DOE) of the United States of 3.5x10{sup 3} {mu}Gy y{sup -1} has been used. The derived absorbed dose rate calculated for Tilapia was 2.51x10{sup 0} {mu}Gy y{sup -1}, that is less than 0.1% of the dose limit established by DOE. The critical radionuclide was Ra-226, with 56% of the absorbed dose rate, followed by U-238 with 34% and Th-232 with 9%. This value of 0.1% of the limit allows to state that, in the operational conditions analyzed, natural radionuclides do not represent a radiological problem to biota.

  15. The multichannel clinic dosimeter for the multiparameter direct control system of absorbed dose in areas of medical interest

    NASA Astrophysics Data System (ADS)

    Sumin, A. V.; Abalakin, I. N.; Medvedkov, A. M.; Smirnova, M. O.; Chernyaev, A. P.; Samosadny, V. T.

    2017-01-01

    The basic principle of radiation therapy is the treatment of a tumor with the maximum reduction in radiation doses to normal organs and tissues. You must implement a plan of irradiation, which will provide the recommended absorbed dose of ionizing radiation in the tumor volume and minimal dose to the tumor surrounding normal tissues and critical organs, at least, less than the tolerant dose for these tissues. There are very stringent requirements on the accuracy of realization of the values of doses. Therefore, the value of the dose must be controlled during the irradiation session. In this case, we will have the opportunity to interrupt the session, and to adjust the program of irradiation to avoid bad consequences. For these purposes, “NIITFA” has developed and manufactured multi-channel dosimeter MKD-04. Specialists Held the first technical and clinical testing of the device, the results confirm the high level capabilities of the dosimeter.

  16. A new gel using super absorbent polymer for mapping the spatial dose distributions of electron beams by MR imager.

    PubMed

    Hiraoka, T; Hoshino, K; Kawashima, K; Kato, H; Tateno, Y

    1993-01-01

    A technique for mapping the spatial dose distribution with a magnetic resonance imager is presented. A ferrous sulphate solution with sulfuric acid was used as the detecting medium for radiation dose. To make a gel of the solution for filling up a cubic phantom, we developed a new gel component that is combined with a super absorbent polymer (Sumikagel N-100) and a cross-linked dextran gel (Sephadex G-200). In order to make the application for radiation treatment planning, mapping of the dose distribution was carried out using a Unix computer.

  17. Absorbed dose distributions for X-ray beams and beams of electrons from the Therac 20 Saturne linear accelerator.

    PubMed

    Tronc, D; Noël, A

    1978-11-01

    After a brief description of the Therac 20 Saturne linear accelerator a complete set of absorbed-dose distribution values is given. These values define the depths on the axis as a function of the depth dose and define the penumbra (as characterized by the positions of the intersections of the isodose curves with planes parallel to the phantom surface) for beams of X-rays and for beams of electrons. Tissue-maximum ratios are given for beams of X-rays. Analytical values for the electron depth dose curve are compared with the values obtained on the Sagittaire linear accelerator.

  18. Tritons at energies of 10 MeV to 1 TeV: conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C.

    PubMed

    Copeland, Kyle; Parker, Donald E; Friedberg, Wallace

    2010-12-01

    Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent for isotropic exposure of an adult female and an adult male to tritons ((3)H(+)) in the energy range of 10 MeV to 1 TeV (0.01-1000 GeV). Coefficients were calculated using Monte Carlo transport code MCNPX 2.7.C and BodyBuilder™ 1.3 anthropomorphic phantoms. Phantoms were modified to allow calculation of effective dose to a Reference Person using tissues and tissue weighting factors from 1990 and 2007 recommendations of the International Commission on Radiological Protection (ICRP) and calculation of gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. At 15 of the 19 energies for which coefficients for effective dose were calculated, coefficients based on ICRP 2007 and 1990 recommendations differed by less than 3%. The greatest difference, 43%, occurred at 30 MeV.

  19. Helions at energies of 10 MeV to 1 TeV: conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C.

    PubMed

    Copeland, Kyle; Parker, Donald E; Friedberg, Wallace

    2010-12-01

    Conversion coefficients were calculated for fluence-to-absorbed dose, fluence-to-equivalent dose, fluence-to-effective dose and fluence-to-gray equivalent, for isotropic exposure of an adult male and an adult female to helions ((3)He(2+)) in the energy range of 10 MeV to 1 TeV (0.01-1000 GeV). Calculations were performed using Monte Carlo transport code MCNPX 2.7.C and BodyBuilder™ 1.3 anthropomorphic phantoms modified to allow calculation of effective dose using tissues and tissue weighting factors from either the 1990 or 2007 recommendations of the International Commission on Radiological Protection (ICRP), and gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. At 15 of the 19 energies for which coefficients for effective dose were calculated, coefficients based on ICRP 2007 and 1990 recommendations differed by less than 2%. The greatest difference, 62%, occurred at 100 MeV.

  20. Absorbed photon dose measurement and calculation for some patient organs examined by computed tomography

    NASA Astrophysics Data System (ADS)

    Shousha, Hany A.

    Patient doses from computed tomography (CT) examinations are usually expressed in terms of dose index, organ doses, and effective dose. The CT dose index (CTDI) can be measured free-in-air or in a CT dosimetry phantom. Organ doses can be measured directly in anthropomorphic Rando phantoms using thermoluminescent detectors. Organ doses can also be calculated by the Monte Carlo method utilizing measured CTDI values. In this work, organ doses were assessed for three main CT examinations: head, chest, and abdomen, using the different mentioned methods. Results of directly measured doses were compared with calculated doses for different organs in the study, and also compared with published international studies.

  1. Determination of the Absorbed Dose Rate to Water for the 18-mm Helmet of a Gamma Knife

    SciTech Connect

    Chung, Hyun-Tai; Park, Youngho; Hyun, Sangil; Choi, Yongsoo; Kim, Gi Hong; Kim, Dong Gyu; Chun, Kook Jin

    2011-04-01

    Purpose: To measure the absorbed dose rate to water of {sup 60}Co gamma rays of a Gamma Knife Model C using water-filled phantoms (WFP). Methods and Materials: Spherical WFP with an equivalent water depth of 5, 7, 8, and 9 cm were constructed. The dose rates at the center of an 18-mm helmet were measured in an 8-cm WFP (WFP-3) and two plastic phantoms. Two independent measurement systems were used: one was calibrated to an air kerma (Set I) and the other was calibrated to the absorbed dose to water (Set II). The dose rates of WFP-3 and the plastic phantoms were converted to dose rates for an 8-cm water depth using the attenuation coefficient and the equivalent water depths. Results: The dose rate measured at the center of WFP-3 using Set II was 2.2% and 1.0% higher than dose rates measured at the center of the two plastic phantoms. The measured effective attenuation coefficient of Gamma Knife photon beam in WFPs was 0.0621 cm{sup -1}. After attenuation correction, the difference between the dose rate at an 8-cm water depth measured in WFP-3 and dose rates in the plastic phantoms was smaller than the uncertainty of the measurements. Conclusions: Systematic errors related to the characteristics of the phantom materials in the dose rate measurement of a Gamma Knife need to be corrected for. Correction of the dose rate using an equivalent water depth and attenuation provided results that were more consistent.

  2. Spreadsheet calculations of absorbed dose to water for photons and electrons according to established dosimetry protocols.

    PubMed

    Cederbaum, M; Kuten, A

    1999-01-01

    The calculation of absorbed dose to water according to a Code of Practice demands a strict adherence to the rules and data of the protocol. To ease the calculations and to avoid computational and methodological errors, we have developed a number of spreadsheets to perform the calculations in accordance with an established dosimetry protocol-in our case those of the International Atomic Energy Agency (IAEA) and the Institution of Physics and Engineering in Medicine and Biology (IPEMB). The spreadsheets are implemented as Microsoft Excel V5.0 worksheets. Only a limited selection of dosimetry equipment is used for calibration, which is performed according to only one of the methods allowed by the protocol. This voluntary limitation of equipment and methods is reflected in a spreadsheet that is beam-specific, compact, focused, and very practical. There are four main spreadsheets: high-energy photons (IAEA), high-energy electrons (IAEA), medium energy X rays (IPEMB), and low-energy X rays (IPEMB). The sheets allow the input of setup and measured data, but tabulated data and formulas are protected. Parameter values are copied from the protocols, and the relevant value is found by linear interpolation. Once the spreadsheets are drawn up correctly and thoroughly checked, protocol calculations are performed easily and accurately. The spreadsheets presented are tailored to suit our specific needs but can easily be modified to conform to the practices of any other institution. They are not intended as "cookbooks" but need to be filled in by a radiation physicist with the input data checked by a second professional. The same method is also used for calculating the Reference Air Kerma Rate of brachytherapy sources.

  3. Accuracy and optimal timing of activity measurements in estimating the absorbed dose of radioiodine in the treatment of Graves' disease

    NASA Astrophysics Data System (ADS)

    Merrill, S.; Horowitz, J.; Traino, A. C.; Chipkin, S. R.; Hollot, C. V.; Chait, Y.

    2011-02-01

    Calculation of the therapeutic activity of radioiodine 131I for individualized dosimetry in the treatment of Graves' disease requires an accurate estimate of the thyroid absorbed radiation dose based on a tracer activity administration of 131I. Common approaches (Marinelli-Quimby formula, MIRD algorithm) use, respectively, the effective half-life of radioiodine in the thyroid and the time-integrated activity. Many physicians perform one, two, or at most three tracer dose activity measurements at various times and calculate the required therapeutic activity by ad hoc methods. In this paper, we study the accuracy of estimates of four 'target variables': time-integrated activity coefficient, time of maximum activity, maximum activity, and effective half-life in the gland. Clinical data from 41 patients who underwent 131I therapy for Graves' disease at the University Hospital in Pisa, Italy, are used for analysis. The radioiodine kinetics are described using a nonlinear mixed-effects model. The distributions of the target variables in the patient population are characterized. Using minimum root mean squared error as the criterion, optimal 1-, 2-, and 3-point sampling schedules are determined for estimation of the target variables, and probabilistic bounds are given for the errors under the optimal times. An algorithm is developed for computing the optimal 1-, 2-, and 3-point sampling schedules for the target variables. This algorithm is implemented in a freely available software tool. Taking into consideration 131I effective half-life in the thyroid and measurement noise, the optimal 1-point time for time-integrated activity coefficient is a measurement 1 week following the tracer dose. Additional measurements give only a slight improvement in accuracy.

  4. First international comparison of primary absorbed dose to water standards in the medium-energy X-ray range

    NASA Astrophysics Data System (ADS)

    Büermann, Ludwig; Guerra, Antonio Stefano; Pimpinella, Maria; Pinto, Massimo; de Pooter, Jacco; de Prez, Leon; Jansen, Bartel; Denoziere, Marc; Rapp, Benjamin

    2016-01-01

    This report presents the results of the first international comparison of primary measurement standards of absorbed dose to water for the medium-energy X-ray range. Three of the participants (VSL, PTB, LNE-LNHB) used their existing water calorimeter based standards and one participant (ENEA) recently developed a new standard based on a water-graphite calorimeter. The participants calibrated three transfer chambers of the same type in terms of absorbed dose to water (NDw) and in addition in terms of air kerma (NK) using the CCRI radiation qualities in the range 100 kV to 250 kV. The additional NK values were intended to be used for a physical analysis of the ratios NDw/NK. All participants had previously participated in the BIPM.RI(I)-K3 key comparison of air kerma standards. Ratios of pairs of NMI's NK results of the current comparison were found to be consistent with the corresponding key comparison results within the expanded uncertainties of 0.6 % - 1 %. The NDw results were analysed in terms of the degrees of equivalence with the comparison reference values which were calculated for each beam quality as the weighted means of all results. The participant's results were consistent with the reference value within the expanded uncertainties. However, these expanded uncertainties varied significantly and ranged between about 1-1.8 % for the water calorimeter based standards and were estimated at 3.7 % for the water-graphite calorimeter. It was shown previously that the ratios NDw/NK for the type of ionization chamber used as transfer chamber in this comparison were very close (within less than 1 %) to the calculated values of (bar muen/ρ)w,ad, the mean values of the water-to-air ratio of the mass-energy-absorption coefficients at the depth d in water. Some of the participant's results deviated significantly from the expected behavior. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of

  5. Comparison of MCNPX and GEANT4 to Predict the Contribution of Non-elastic Nuclear Interactions to Absorbed Dose in Water, PMMA and A150

    NASA Astrophysics Data System (ADS)

    Shtejer, K.; Arruda-Neto, J. D. T.; Schulte, R.; Wroe, A.; Rodrigues, T. E.; de Menezes, M. O.; Moralles, M.; Guzmán, F.; Manso, M. V.

    2008-08-01

    Proton induced non-elastic nuclear reactions play an important role in the dose distribution of clinically used proton beams as they deposit dose of high biological effectiveness both within the primary beam path as well as outside the beam to untargeted tissues. Non-elastic nuclear reactions can be evaluated using transport codes based on the Monte Carlo method. In this work, we have utilized the Los Alamos code MCNPX and the CERN GEANT4 toolkit, which are currently the most widely used Monte Carlo programs for proton radiation transport simulations in medical physics, to study the contribution of non-elastic nuclear interactions to the absorbed dose of proton beams in the therapeutic energy range. The impact of different available theoretical models to address the nuclear reaction process was investigated. The contribution of secondary particles from non-elastic nuclear reactions was calculated in three materials relevant in radiotherapy applications: water, PMMA and A150. The results evidence that there are differences in the calculated contribution of the secondary particles heavier than protons to the absorbed dose, with different approaches to model the nuclear reactions. The MCNPX calculation give rise to a larger contribution of d, t, α3He to the total dose compared to the GEANT4 physical models chosen in this work.

  6. Comparison of MCNPX and GEANT4 to Predict the Contribution of Non-elastic Nuclear Interactions to Absorbed Dose in Water, PMMA and A150

    SciTech Connect

    Shtejer, K.; Arruda-Neto, J. D. T.; Rodrigues, T. E.; Schulte, R.; Wroe, A.; Menezes, M. O. de; Moralles, M.

    2008-08-11

    Proton induced non-elastic nuclear reactions play an important role in the dose distribution of clinically used proton beams as they deposit dose of high biological effectiveness both within the primary beam path as well as outside the beam to untargeted tissues. Non-elastic nuclear reactions can be evaluated using transport codes based on the Monte Carlo method. In this work, we have utilized the Los Alamos code MCNPX and the CERN GEANT4 toolkit, which are currently the most widely used Monte Carlo programs for proton radiation transport simulations in medical physics, to study the contribution of non-elastic nuclear interactions to the absorbed dose of proton beams in the therapeutic energy range. The impact of different available theoretical models to address the nuclear reaction process was investigated. The contribution of secondary particles from non-elastic nuclear reactions was calculated in three materials relevant in radiotherapy applications: water, PMMA and A150. The results evidence that there are differences in the calculated contribution of the secondary particles heavier than protons to the absorbed dose, with different approaches to model the nuclear reactions. The MCNPX calculation give rise to a larger contribution of d, t, {alpha}{sup 3}He to the total dose compared to the GEANT4 physical models chosen in this work.

  7. Wideband long wave infrared metamaterial absorbers based on silicon nitride

    NASA Astrophysics Data System (ADS)

    Üstün, Kadir; Turhan-Sayan, Gönül

    2016-11-01

    In this paper, we present silicon nitride metamaterial absorber designs that accomplish large bandwidth and high absorption in the long wave infrared (LWIR) region. These designs are based on the metal-insulator-metal topology, insulator (silicon nitride), and the top metal (aluminum) layers are optimized to obtain high absorptance values in large bandwidths, for three different silicon nitride based absorber structures. The absorption spectrum of the final design reaches absorptance values above 90% in the wavelength interval between 8.07 μm and 11.97 μm, and above 80% in the wavelength interval between 7.9 μm and 14 μm, in the case of normal incidence. The difficulty in the design process of such absorbers stems from the highly dispersive behavior of silicon nitride in the LWIR region. On the other hand, silicon nitride is a widely used material in microbolometers, and accomplishing wide band absorption in silicon nitride is crucial in this regard. Therefore, this study will pave the way for more efficient infrared imaging devices, which are crucial for defense and security systems. Additionally, such designs may also find applications in thermal emitters.

  8. Comparison of various techniques for the exact determination of absorbed dose in heavy ion fields using passive detectors

    NASA Astrophysics Data System (ADS)

    Berger, T.; Reitz, G.; Hajek, M.; Vana, N.

    Passive thermoluminescent detectors (TLDs) are commonly applied for the determination of absorbed dose in routine radiation protection. The usage of TLDs in heavy ion fields, e.g., in space dosimetry or for treatment planing in radiotherapy, requires the detailed knowledge of the efficiency of these detectors to the ion under study in dependence on the LET of the ion. This is due to the fact, that the detection efficiency of TLDs changes with increasing LET. If the changing efficiency of the TL-material is not taken into account, this would lead to a deviation of the measured absorbed dose. In the framework of the ICCHIBAN project - which was started as an intercomparison of passive and active detector systems used for dose determination in space - "BLIND" exposures were carried out. No information about dose and ion species was given to the investigators. Three different methods were used for the efficiency correction of TLDs after the BLIND exposures. The first method used the different LET efficiency of the TL-materials LiF:Mg, Ti and LiF:Mg, Cu, P to determine the LET and from this LET the efficiency of the LiF:Mg, Ti dosemeters. The second method used the high temperature emissions in LiF:Mg, Ti for the efficiency correction. The third method used a combination of TLDs and CR-39 track etch detectors to determine the total absorbed dose during the BLIND exposures. The paper will discuss the three methods, and focus on their applicability to precise dose determination and recalculation in space dosimetry.

  9. Assessment of breast absorbed doses during thoracic computed tomography scan to evaluate the effectiveness of bismuth shielding.

    PubMed

    Alonso, Thessa C; Mourão, Arnaldo P; Santana, Priscila C; da Silva, Teógenes A

    2016-11-01

    During a lung computed tomography (CT) examination, breast and nearby radiosensitive organs are unnecessarily irradiated because they are in the path of the primary beam. The purpose of this paper is to determine the absorbed dose in breast and nearby organs for unshielded and shielded exposures with bismuth. The experiment was done with a female anthropomorphic phantom undergoing a typical thoracic CT scan, with TLD-100 thermoluminescent detectors insert at breast, lung and thyroid positions. Results showed that dose reduction due to bismuth shielding was approximately 30% and 50% for breast and thyroid, respectively; however, the influence of the bismuth on the image quality needs to be considered.

  10. Mean Absorbed Dose to the Anal-Sphincter Region and Fecal Leakage among Irradiated Prostate Cancer Survivors

    SciTech Connect

    Alsadius, David; Hedelin, Maria; Lundstedt, Dan; Pettersson, Niclas; Wilderaeng, Ulrica; Steineck, Gunnar

    2012-10-01

    Purpose: To supplement previous findings that the absorbed dose of ionizing radiation to the anal sphincter or lower rectum affects the occurrence of fecal leakage among irradiated prostate-cancer survivors. We also wanted to determine whether anatomically defining the anal-sphincter region as the organ at risk could increase the degree of evidence underlying clinical guidelines for restriction doses to eliminate this excess risk. Methods and Materials: We identified 985 men irradiated for prostate cancer between 1993 and 2006. In 2008, we assessed long-term gastrointestinal symptoms among these men using a study-specific questionnaire. We restrict the analysis to the 414 men who had been treated with external beam radiation therapy only (no brachytherapy) to a total dose of 70 Gy in 2-Gy daily fractions to the prostate or postoperative prostatic region. On reconstructed original radiation therapy dose plans, we delineated the anal-sphincter region as an organ at risk. Results: We found that the prevalence of long-term fecal leakage at least once per month was strongly correlated with the mean dose to the anal-sphincter region. Examining different dose intervals, we found a large increase at 40 Gy; {>=}40 Gy compared with <40 Gy gave a prevalence ratio of 3.8 (95% confidence interval 1.6-8.6). Conclusions: This long-term study shows that mean absorbed dose to the anal-sphincter region is associated with the occurrence of long-term fecal leakage among irradiated prostate-cancer survivors; delineating the anal-sphincter region separately from the rectum and applying a restriction of a mean dose <40 Gy will, according to our data, reduce the risk considerably.

  11. SU-F-207-05: Excess Heat Corrections in a Prototype Calorimeter for Direct Realization of CT Absorbed Dose to Phantom

    SciTech Connect

    Chen-Mayer, H; Tosh, R

    2015-06-15

    Purpose: To reconcile air kerma and calorimetry measurements in a prototype calorimeter for obtaining absorbed dose in diagnostic CT beams. While corrections for thermal artifacts are routine and generally small in calorimetry of radiotherapy beams, large differences in relative stopping powers of calorimeter materials at the lower energies typical of CT beams greatly magnify their effects. Work-to-date on the problem attempts to reconcile laboratory measurements with modeling output from Monte Carlo and finite-element analysis of heat transfer. Methods: Small thermistor beads were embedded in a polystyrene (PS) core element of 1 cm diameter, which was inserted into a cylindrical HDPE phantom of 30 cm diameter and subjected to radiation in a diagnostic CT x-ray imaging system. Resistance changes in the thermistors due to radiation heating were monitored via lock-in amplifier. Multiple 3-second exposures were recorded at 8 different dose-rates from the CT system, and least-squares fits to experimental data were compared to an expected thermal response obtained by finite-element analysis incorporating source terms based on semi-empirical modeling and Monte Carlo simulation. Results: Experimental waveforms exhibited large thermal artifacts with fast time constants, associated with excess heat in wires and glass, and smaller steps attributable to radiation heating of the core material. Preliminary finite-element analysis follows the transient component of the signal qualitatively, but predicts a slower decay of temperature spikes. This was supplemented by non-linear least-squares fits incorporating semi-empirical formulae for heat transfer, which were used to obtain dose-to-PS in reasonable agreement with the output of Monte Carlo calculations that converts air kerma to absorbed dose. Conclusion: Discrepancies between the finite-element analysis and our experimental data testify to the very significant heat transfer correction required for absorbed dose calorimetry of

  12. Evaluation of absorbed dose in irradiated sugar-containing plant material (peony roots) by an ESR method

    NASA Astrophysics Data System (ADS)

    Yamaoki, Rumi; Kimura, Shojiro; Ohta, Masatoshi

    2015-12-01

    The relationship between electron spin resonance (ESR) signal intensity of irradiated plant materials and sugar content was investigated by spectral analysis using peony roots. A weak background signal near g=2.005 was observed in the roots. After a 10 kGy irradiation, the ESR line broadened and the intensity increased, and the spectral characteristics were similar to a typical spectrum of irradiated food containing crystalline sugars. The free radical concentration was nearly stable 30 days after irradiation. The spectrum of peony root 30 days after irradiation was simulated using the summation of the intensities of six assumed components: radical signals derived from (a) sucrose, (b) glucose, (c) fructose, (d) cellulose, (e) the background signal near g=2.005 and (f) unidentified component. The simulated spectra using the six components were in agreement with the observed sample spectra. The intensity of sucrose radical signal in irradiated samples increased proportionally up to 20 kGy. In addition, the intensity of sucrose radical signals was strongly correlated with the sucrose contents of the samples. The results showed that the radiation sensitivity of sucrose in peony roots was influenced little by other plant constituents. There was also a good correlation between the total area of the spectra and the sucrose content, because the sucrose content was higher than that of other sugars in the samples. In peony roots, estimation of the absorbed dose from the ESR signal intensity may be possible by a calibration method based on the sucrose content.

  13. Depth dependence of absorbed dose, dose equivalent and linear energy transfer spectra of galactic and trapped particles in polyethylene and comparison with calculations of models

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Cucinotta, F. A.; Wilson, J. W. (Principal Investigator)

    1998-01-01

    A matched set of five tissue-equivalent proportional counters (TEPCs), embedded at the centers of 0 (bare), 3, 5, 8 and 12-inch-diameter polyethylene spheres, were flown on the Shuttle flight STS-81 (inclination 51.65 degrees, altitude approximately 400 km). The data obtained were separated into contributions from trapped protons and galactic cosmic radiation (GCR). From the measured linear energy transfer (LET) spectra, the absorbed dose and dose-equivalent rates were calculated. The results were compared to calculations made with the radiation transport model HZETRN/NUCFRG2, using the GCR free-space spectra, orbit-averaged geomagnetic transmission function and Shuttle shielding distributions. The comparison shows that the model fits the dose rates to a root mean square (rms) error of 5%, and dose-equivalent rates to an rms error of 10%. Fairly good agreement between the LET spectra was found; however, differences are seen at both low and high LET. These differences can be understood as due to the combined effects of chord-length variation and detector response function. These results rule out a number of radiation transport/nuclear fragmentation models. Similar comparisons of trapped-proton dose rates were made between calculations made with the proton transport model BRYNTRN using the AP-8 MIN trapped-proton model and Shuttle shielding distributions. The predictions of absorbed dose and dose-equivalent rates are fairly good. However, the prediction of the LET spectra below approximately 30 keV/microm shows the need to improve the AP-8 model. These results have strong implications for shielding requirements for an interplanetary manned mission.

  14. The development of early pediatric models and their application to radiation absorbed dose calculations

    SciTech Connect

    Poston, J.W.

    1989-01-01

    This presentation will review and describe the development of pediatric phantoms for use in radiation dose calculations . The development of pediatric models for dose calculations essentially paralleled that of the adult. In fact, Snyder and Fisher at the Oak Ridge National Laboratory reported on a series of phantoms for such calculations in 1966 about two years before the first MIRD publication on the adult human phantom. These phantoms, for a newborn, one-, five-, ten-, and fifteen-year old, were derived from the adult phantom. The pediatric'' models were obtained through a series of transformations applied to the major dimensions of the adult, which were specified in a Cartesian coordinate system. These phantoms suffered from the fact that no real consideration was given to the influence of these mathematical transformations on the actual organ sizes in the other models nor to the relation of the resulting organ masses to those in humans of the particular age. Later, an extensive effort was invested in designing individual'' pediatric phantoms for each age based upon a careful review of the literature. Unfortunately, the phantoms had limited use and only a small number of calculations were made available to the user community. Examples of the phantoms, their typical dimensions, common weaknesses, etc. will be discussed.

  15. The development of early pediatric models and their application to radiation absorbed dose calculations

    SciTech Connect

    Poston, J.W.

    1989-12-31

    This presentation will review and describe the development of pediatric phantoms for use in radiation dose calculations . The development of pediatric models for dose calculations essentially paralleled that of the adult. In fact, Snyder and Fisher at the Oak Ridge National Laboratory reported on a series of phantoms for such calculations in 1966 about two years before the first MIRD publication on the adult human phantom. These phantoms, for a newborn, one-, five-, ten-, and fifteen-year old, were derived from the adult phantom. The ``pediatric`` models were obtained through a series of transformations applied to the major dimensions of the adult, which were specified in a Cartesian coordinate system. These phantoms suffered from the fact that no real consideration was given to the influence of these mathematical transformations on the actual organ sizes in the other models nor to the relation of the resulting organ masses to those in humans of the particular age. Later, an extensive effort was invested in designing ``individual`` pediatric phantoms for each age based upon a careful review of the literature. Unfortunately, the phantoms had limited use and only a small number of calculations were made available to the user community. Examples of the phantoms, their typical dimensions, common weaknesses, etc. will be discussed.

  16. Reconstruction of Absorbed Doses to Fibroglandular Tissue of the Breast of Women undergoing Mammography (1960 to the Present)

    PubMed Central

    Thierry-Chef, Isabelle; Simon, Steven L.; Weinstock, Robert M.; Kwon, Deukwoo; Linet, Martha S.

    2013-01-01

    The assessment of potential benefits versus harms from mammographic examinations as described in the controversial breast cancer screening recommendations of the U.S. Preventive Task Force included limited consideration of absorbed dose to the fibroglandular tissue of the breast (glandular tissue dose), the tissue at risk for breast cancer. Epidemiological studies on cancer risks associated with diagnostic radiological examinations often lack accurate information on glandular tissue dose, and there is a clear need for better estimates of these doses. Our objective was to develop a quantitative summary of glandular tissue doses from mammography by considering sources of variation over time in key parameters including imaging protocols, x-ray target materials, voltage, filtration, incident air kerma, compressed breast thickness, and breast composition. We estimated the minimum, maximum, and mean values for glandular tissue dose for populations of exposed women within 5-year periods from 1960 to the present, with the minimum to maximum range likely including 90% to 95% of the entirety of the dose range from mammography in North America and Europe. Glandular tissue dose from a single view in mammography is presently about 2 mGy, about one-sixth the dose in the 1960s. The ratio of our estimates of maximum to minimum glandular tissue doses for average-size breasts was about 100 in the 1960s compared to a ratio of about 5 in recent years. Findings from our analysis provide quantitative information on glandular tissue doses from mammographic examinations which can be used in epidemiologic studies of breast cancer. PMID:21988547

  17. Estimation of absorbed dose in clinical radiotherapy linear accelerator beams: Effect of ion chamber calibration and long-term stability.

    PubMed

    Ravichandran, Ramamoorthy; Binukumar, Johnson Pichy; Davis, Cheriyathmanjiyil Antony

    2013-10-01

    The measured dose in water at reference point in phantom is a primary parameter for planning the treatment monitor units (MU); both in conventional and intensity modulated/image guided treatments. Traceability of dose accuracy therefore still depends mainly on the calibration factor of the ion chamber/dosimeter provided by the accredited Secondary Standard Dosimetry Laboratories (SSDLs), under International Atomic Energy Agency (IAEA) network of laboratories. The data related to Nd,water calibrations, thermoluminescent dosimetry (TLD) postal dose validation, inter-comparison of different dosimeter/electrometers, and validity of Nd,water calibrations obtained from different calibration laboratories were analyzed to find out the extent of accuracy achievable. Nd,w factors in Gray/Coulomb calibrated at IBA, GmBH, Germany showed a mean variation of about 0.2% increase per year in three Farmer chambers, in three subsequent calibrations. Another ion chamber calibrated in different accredited laboratory (PTW, Germany) showed consistent Nd,w for 9 years period. The Strontium-90 beta check source response indicated long-term stability of the ion chambers within 1% for three chambers. Results of IAEA postal TL "dose intercomparison" for three photon beams, 6 MV (two) and 15 MV (one), agreed well within our reported doses, with mean deviation of 0.03% (SD 0.87%) (n = 9). All the chamber/electrometer calibrated by a single SSDL realized absorbed doses in water within 0.13% standard deviations. However, about 1-2% differences in absorbed dose estimates observed when dosimeters calibrated from different calibration laboratories are compared in solid phantoms. Our data therefore imply that the dosimetry level maintained for clinical use of linear accelerator photon beams are within recommended levels of accuracy, and uncertainties are within reported values.

  18. Comparison of mathematical models for red marrow and blood absorbed dose estimation in the radioiodine treatment of advanced differentiated thyroid carcinoma

    NASA Astrophysics Data System (ADS)

    Miranti, A.; Giostra, A.; Richetta, E.; Gino, E.; Pellerito, R. E.; Stasi, M.

    2015-02-01

    Metastatic and recurrent differentiated thyroid carcinoma is preferably treated with 131I, whose administered activity is limited by red marrow (RM) toxicity, originally correlated by Benua to a blood absorbed dose higher than 2 Gy. Afterward a variety of dosimetric approaches has been proposed. The aim of this work is to compare the results of the Benua formula with the ones of other three blood and RM absorbed dose formulae. Materials and methods have been borrowed by the dosimetric protocol of the Italian Internal Dosimetry group and adapted to the routine of our centre. Wilcoxon t-tests and percentage differences have been applied for comparison purposes. Results are significantly different (p < 0.05) from each other, with an average percentage difference between Benua versus other results of -22%. The dosimetric formula applied to determine blood or RM absorbed dose may contribute significantly to increase heterogeneity in absorbed dose and dose-response results. Standardization should be a major objective.

  19. Porphyrin Based Near Infrared-Absorbing Materials for Organic Photovoltaics

    NASA Astrophysics Data System (ADS)

    Zhong, Qiwen

    The conservation and transformation of energy is essential to the survival of mankind, and thus concerns every modern society. Solar energy, as an everlasting source of energy, holds one of the key solutions to some of the most urgent problems the world now faces, such as global warming and the oil crisis. Advances in technologies utilizing clean, abundant solar energy, could be the steering wheel of our societies. Solar cells, one of the major advances in converting solar energy into electricity, are now capturing people's interest all over the globe. While solar cells have been commercially available for many years, the manufacturing of solar cells is quite expensive, limiting their broad based implementation. The cost of solar cell based electricity is 15-50 cents per kilowatt hour (¢/kwh), depending on the type of solar cell, compared to 0.7 ¢/kwh for fossil fuel based electricity. Clearly, decreasing the cost of electricity from solar cells is critical for their wide spread deployment. This will require a decrease in the cost of light absorbing materials and material processing used in fabricating the cells. Organic photovoltaics (OPVs) utilize organic materials such as polymers and small molecules. These devices have the advantage of being flexible and lower cost than conventional solar cells built from inorganic semiconductors (e.g. silicon). The low cost of OPVs is tied to lower materials and fabrication costs of organic cells. However, the current power conversion efficiencies of OPVs are still below 15%, while convention crystalline Si cells have efficiencies of 20-25%. A key limitation in OPVs today is their inability to utilize the near infrared (NIR) portion of the solar spectrum. This part of the spectrum comprises nearly half of the energy in sunlight that could be used to make electricity. The first and foremost step in conversion solar energy conversion is the absorption of light, which nature has provided us optimal model of, which is

  20. Multiple myeloma among atomic bomb survivors in Hiroshima and Nagasaki, 1950-76: relationship to radiation dose absorbed by marrow

    SciTech Connect

    Ichimaru, M.; Ishimaru, T.; Mikami, M.; Matsunaga, M.

    1982-08-01

    The relationship between atomic bomb exposure and the incidence of multiple myeloma has been examined in a fixed cohort of atomic bomb survivors and controls in the life-span study sample for Hiroshima and Nagasaki. From October 1950 to December 1976, 29 cases of multiple myeloma were confirmed in this sample. Our analysis shows that the standardized relative risk (RR) adjusted for city, sex, and age at the time of bombings (ATB) increased with marrow-absorbed radiation dose. The increased RR does not appear to differ between cities or sexes and is demonstrable only for those survivors whose age ATB was between 20 and 59 years. The estimated risk in these individuals is approximately 0.48 cases/million person-years/rad for bone marrow total dose. This excess risk did not become apparent in individuals receiving 50 rad or more in marrow total dose until 20 years or more after exposure.

  1. Multiple myeloma among atomic bomb survivors in Hiroshima and Nagasaki, 1950-76: relationship to radiation dose absorbed by marrow.

    PubMed

    Ichimaru, M; Ishimaru, T; Mikami, M; Matsunaga, M

    1982-08-01

    The relationship between atomic bomb exposure and the incidence of multiple myeloma has been examined in a fixed cohort of atomic bomb survivors and controls in the life-span study sample for Hiroshima and Nagasaki. From October 1950 to December 1976, 29 cases of multiple myeloma were confirmed in this sample. Our analysis shows that the standardized relative risk (RR) adjusted for city, sex, and age at the time of bombings (ATB) increased with marrow-absorbed radiation dose. The increased RR does not appear to differ between cities or sexes and is demonstrable only for those survivors whose age ATB was between 20 and 59 years. The estimated risk in these individuals is approximately 0.48 cases/million person-years/rad for bone marrow total dose. This excess risk did not become apparent in individuals receiving 50 rad or more in marrow total dose until 20 years or more after exposure.

  2. Multiple myeloma among atomic bomb survivors in Hiroshima and Nagasaki, 1950-76: relationship to radiation dose absorbed by marrow

    SciTech Connect

    Ichimaru, M.; Ishimaru, T.; Mikami, M.; Matsunaga, M.

    1982-08-01

    The relationship between atomic bomb exposure and the incidence of multiple myeloma has been examined in a fixed cohort of atomic bomb survivors and controls in the life-span study sample for Hiroshima and Nagasaki. From October 1950 to December 1976, 29 cases of multiple myeloma were confirmed in this sample. Our analysis shows that the standardized relative risk (RR) adjusted for city, sex, and age at the time of bombings (ATB) increased with marrow-absorbed radiation dose. The increased RR does not appear to differ between cities or sexes and is demonstrable only for those survivors whose age ATB was between 20 and 59 years. The estimaged risk in these individuals is approximately 0.48 cases/million person-years/rad for bone marrow total dose. This excess risk did not become apparent in individuals receiving 50 rad or more in marrow total dose until 20 years or more after exposure.

  3. Calculation of. beta. -ray absorbed dose rate for /sup 131/I applied to the inflorescence of Tradescantia

    SciTech Connect

    Bingo, K.; Tano, S.; Numakunai, T.; Yoshida, Y.; Yamaguchi, H.

    1981-03-01

    Effects of /sup 131/I applied to the inflorescence on the induction of somatic mutations in Tradescantia stamen hairs were previously investigated, and the doubling dose (activity) was estimated to be 4 nCi. In the present paper, the absorbed dose rate in stamen hairs of Tradescantia for ..beta.. rays from the applied /sup 131/I was calculated. The doubling dose for the /sup 131/I (4 nCi) applied to the inflorescence was estimated to be higher than 0.3 rad (assuming uniform distribution of /sup 131/I on the surface of the buds and assuming that the shape of the buds was a sphere) and lower than 1.0 rad.

  4. Study of the spatial distribution of the absorbed dose in blood volumes irradiated using a teletherapy unit

    NASA Astrophysics Data System (ADS)

    Góes, E. G.; Nicolucci, P.; Nali, I. C.; Pelá, C. A.; Bruço, J. L.; Borges, J. C.; Covas, D. T.

    2010-06-01

    Blood irradiation can be performed using a dedicated blood irradiator or a teletherapy unit. A thermal device providing appropriate storage conditions during blood components irradiation with a teletherapy unit has been recently proposed. However, the most appropriated volume of the thermal device was not indicated. The goal of this study was to indicate the most appropriated blood volume for irradiation using a teletherapy unit in order to minimize both the dose heterogeneity in the volume and the blood irradiation time using these equipments. Theoretical and experimental methods were used to study the dose distribution in the blood volume irradiated using a linear accelerator and a cobalt-60 therapy machine. The calculation of absorbed doses in the middle plane of cylindrical acrylic volumes was accomplished by a treatment planning system. Experimentally, we also used cylindrical acrylic phantoms and thermoluminescent dosimeters to confirm the calculated doses. The data obtained were represented by isodose curves. We observed that an irradiation volume should have a height of 28 cm and a diameter of 28 cm and a height of 35 cm and a diameter of 35 cm, when the irradiation is to be performed by a linear accelerator and a cobalt-60 teletherapy unit, respectively. Calculated values of relative doses varied from 93% to 100% in the smaller volume, and from 66% to 100% in the largest one. A difference of 5.0%, approximately, was observed between calculated and experimental data. The size of these volumes permits the irradiation of blood bags in only one bath without compromising the homogeneity of the absorbed dose over the irradiated volume. Thus, these irradiation volumes can be recommend to minimize the irradiation time when a teletherapy unit is used to irradiate blood.

  5. A fibre optic scintillator dosemeter for absorbed dose measurements of low-energy X-ray-emitting brachytherapy sources.

    PubMed

    Sliski, Alan; Soares, Christopher; Mitch, Michael G

    2006-01-01

    A newly developed dosemeter using a 0.5 mm diameter x 0.5 mm thick cylindrical plastic scintillator coupled to the end of a fibre optic cable is capable of measuring the absorbed dose rate in water around low-activity, low-energy X-ray emitters typically used in prostate brachytherapy. Recent tests of this dosemeter showed that it is possible to measure the dose rate as a function of distance in water from 2 to 30 mm of a (103)Pd source of air-kerma strength 3.4 U (1 U = 1 microGy m(2) h(-1)), or 97 MBq (2.6 mCi) apparent activity, with good signal-to-noise ratio. The signal-to-noise ratio is only dependent on the integration time and background subtraction. The detector volume is enclosed in optically opaque, nearly water-equivalent materials so that there is no polar response other than that due to the shape of the scintillator volume chosen, in this case cylindrical. The absorbed dose rate very close to commercial brachytherapy sources can be mapped in an automated water phantom, providing a 3-D dose distribution with sub-millimeter spatial resolution. The sensitive volume of the detector is 0.5 mm from the end of the optically opaque waterproof housing, enabling measurements at very close distances to sources. The sensitive detector electronics allow the measurement of very low dose rates, as exist at centimeter distances from these sources. The detector is also applicable to mapping dose distributions from more complex source geometries such as eye applicators for treating macular degeneration.

  6. Absorbed dose measurements in dual energy X-ray absorptiometry (DXA).

    PubMed

    Bezakova, E; Collins, P J; Beddoe, A H

    1997-02-01

    In this study a predominantly film dosimetric method was used to measure the effective dose from posteroanterior (PA) lumbar spine and proximal femur scans performed on a Lunar DPX-L machine. Because of the very low dose rate in scanning mode, the depth dose data were determined using a stationary detector configuration. The characteristic curve for the film (Kodak TMAT-H) was obtained and depth dose measurements were made using slabs of "solid water". The film was calibrated using a superficial X-ray unit (calibrated against a standard traceable to a national standard). To assess the change in film response with beam hardening at depth, the film was exposed to calibration beams of different half value layer (HVL). The HVL of the DXA beam was determined for surface and depth doses using aluminium filters and a diamond detector (an energy independent device). All measurements were performed three times. Beam size was measured using film, and the scan areas and times were determined by scanning phantoms. The dose from a scan was calculated using Dsc = DTscAb/Asc, where D = dose rate (stationary), Tsc = scan time, Ab = beam area, and Asc = scan area. Organ doses were determined using an anatomical atlas and ICRP 23 female reference. All film measurements had good precision (coefficient of variation < 4%). There was little variation in film sensitivity with change in HVL (< 1% change for the first three HVLs) and consequently no corrections were applied to the depth dose data. Skin entrance dose was 11.5 microGy. Effective dose in females was 0.19 microSv for the PA lumbar spine. For the proximal femur scan, the effective dose was 0.14 microSv (ovaries included) and 0.023 microSv (ovaries excluded) for pre-menopausal and pos-menopausal women, respectively.

  7. SU-E-T-30: Absorbed Doses Determined by Texture Analysis of Gafchromic EBT3 Films Using Scanning Electron Microscopy: A Feasibility Study

    SciTech Connect

    Park, S; Kim, H; Ye, S

    2014-06-01

    Purpose: The texture analysis method is useful to estimate structural features of images as color, size, and shape. The study aims to determine a dose-response curve by texture analysis of Gafchromic EBT3 film images using scanning electron microscopy (SEM). Methods: The uncoated Gafchromic EBT3 films were prepared to directly scan over the active surface layer of EBT3 film using SEM. The EBT3 films were exposed at a dose range of 0 to 10 Gy using a 6 MV photon beam. The exposed film samples were SEM-scanned at 100X, 1000X, and 3000X magnifications. The four texture features (Homogeneity, Correlation, Contrast, and Energy) were calculated based on the gray level co-occurrence matrix (GLCM) derived from the SEM images at each dose. To validate a correlation between delivered doses and texture features, an R-squared value in linear regression was tested. Results: The results showed that the Correlation index was more suitable as dose indices than the other three texture features due to higher linearity and sensitivity of the dose response curves. Further the Correlation index of 3000X magnified SEM images with 9 pixel offsets had an R-squared value of 0.964. The differences between the delivered doses and the doses measured by this method were 0.9, 1.2, 0.2, and 0.2 Gy at 5, 10, 15, and 20 Gy, respectively. Conclusion: It seems to be feasible to convert micro-scale structural features of {sub χ}t{sub χχχ}he EBT3 films to absorbed doses using the texture analysis method.

  8. Transition metal dichalcogenides based saturable absorbers for pulsed laser technology

    NASA Astrophysics Data System (ADS)

    Mohanraj, J.; Velmurugan, V.; Sivabalan, S.

    2016-10-01

    Ultrashort pulsed laser is an indispensable tool for the evolution of photonic technology in the present and future. This laser has been progressing tremendously with new pulse regimes and incorporating novel devices inside its cavity. Recently, a nanomaterial based saturable absorber (SA) was used in ultrafast laser that has improved the lasing performance and caused a reduction in the physical dimension when compared to conventional SAs. To date, the nanomaterials that are exploited for the development of SA devices are carbon nanotubes, graphene, topological insulators, transition metal dichalcogenides (TMDs) and black phosphorous. These materials have unique advantages such as high nonlinear optical response, fiber compatibility and ease of fabrication. In these, TMDs are prominent and an emerging two-dimensional nanomaterial for photonics and optoelectronics applications. Therefore, we review the reports of Q-switched and mode-locked pulsed lasers using TMDs (specifically MoS2, MoSe2, WS2 and WSe2) based SAs.

  9. Ultra-broadband microwave metamaterial absorber based on resistive sheets

    NASA Astrophysics Data System (ADS)

    Kim, Y. J.; Yoo, Y. J.; Hwang, J. S.; Lee, Y. P.

    2017-01-01

    We investigate a broadband perfect absorber for microwave frequencies, with a wide incident angle, using resistive sheets, based on both simulation and experiment. The absorber uses periodically-arranged meta-atoms, consisting of snake-shape metallic patterns and metal planes separated by three resistive sheet layers between four dielectric layers. We demonstrate the mechanism of the broadband by impedance matching with free space, and the distribution of surface currents at specific frequencies. In simulation, the absorption was over 96% in 1.4-6.0 GHz. The corresponding experimental absorption band over 96% was 1.4-4.0 GHz, however, the absorption was lower than 96% in the 4.0-6.0 GHz range because of the rather irregular thickness of the resistive sheets. Furthermore, it works for wide incident angles and is relatively independent of polarization. The design is scalable to smaller sizes in the THz range. The results of this study show potential for real applications in prevention of microwave frequency exposure, with devices such as cell phones, monitors, and microwave equipment.

  10. Treatment of small-cell lung cancer xenografts with iodine-313-anti-neural cell adhesion molecule monoclonal antibody and evaluation of absorbed dose in tissue

    SciTech Connect

    Hosono, Makoto; Endo, Keigo; Hosono, Masako N.

    1994-02-01

    Human small-cell lung cancer (SCLC) is considered a feasible target for immunotherapy using a radiolabeled monoclonal antibody (Mab). A murine Mab, NE150 (IgG1), reacts with the neural cell adhesion molecule, which is identical to cluster 1 antigen of SCLC. To estimate their therapeutic effects, NE150 and an isotype-matched control Mab were labeled with {sup 131}I and administered intravenously as a single dose into athymic mice inoculated with a NCI-H69 SCLC xenograft. The absorbed dose in organs was also examined based upon a long-term biodistribution study of {sup 131}I-NE150. Tumors initial volume 563.4 {plus_minus} 223.5 mm{sup 3} treated with 11.1 MBq (300 {mu}Ci) of {sup 131}I-NE150 diminished and became invisible at days 30-33, demonstrating a 60-day mean growth delay to reach a tripled initial volume compared with sham-treated tumors. Cumulative absorbed doses were estimated to be 2310, 410, 500, 330, and 790 cGy for the tumor, liver, kidney, spleen and lung, respectively. Iodine-131-NE150 had potent therapeutic effects against SCLC transplants in athymic mice, however, careful assessment of the side effects, improvement of radioiodination and chimerization of the Mab might be necessary to achieve efficient targeting in clinical therapeutic applications. 25 refs., 2 figs., 3 tabs.

  11. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an {sup 192}Ir brachytherapy source

    SciTech Connect

    Lucas, P. Avilés Aubineau-Lanièce, I.; Lourenço, V.; Vermesse, D.; Cutarella, D.

    2014-01-15

    Purpose: The absorbed dose to water is the fundamental reference quantity for brachytherapy treatment planning systems and thermoluminescence dosimeters (TLDs) have been recognized as the most validated detectors for measurement of such a dosimetric descriptor. The detector response in a wide energy spectrum as that of an{sup 192}Ir brachytherapy source as well as the specific measurement medium which surrounds the TLD need to be accounted for when estimating the absorbed dose. This paper develops a methodology based on highly sensitive LiF:Mg,Cu,P TLDs to directly estimate the absorbed dose to water in liquid water around a high dose rate {sup 192}Ir brachytherapy source. Methods: Different experimental designs in liquid water and air were constructed to study the response of LiF:Mg,Cu,P TLDs when irradiated in several standard photon beams of the LNE-LNHB (French national metrology laboratory for ionizing radiation). Measurement strategies and Monte Carlo techniques were developed to calibrate the LiF:Mg,Cu,P detectors in the energy interval characteristic of that found when TLDs are immersed in water around an{sup 192}Ir source. Finally, an experimental system was designed to irradiate TLDs at different angles between 1 and 11 cm away from an {sup 192}Ir source in liquid water. Monte Carlo simulations were performed to correct measured results to provide estimates of the absorbed dose to water in water around the {sup 192}Ir source. Results: The dose response dependence of LiF:Mg,Cu,P TLDs with the linear energy transfer of secondary electrons followed the same variations as those of published results. The calibration strategy which used TLDs in air exposed to a standard N-250 ISO x-ray beam and TLDs in water irradiated with a standard{sup 137}Cs beam provided an estimated mean uncertainty of 2.8% (k = 1) in the TLD calibration coefficient for irradiations by the {sup 192}Ir source in water. The 3D TLD measurements performed in liquid water were obtained with a

  12. Accidental embryo irradiation during barium enema examinations: An estimation of absorbed dose

    SciTech Connect

    Damilakis, J.; Perisinakis, K.; Grammatikakis, J.

    1996-04-01

    The purpose of this report is to investigate the possibility of an embryo to receive a dose of more than 10 cGy, the threshold of malformation induction in embryos reported by the International Commission on Radiological Protection, during barium enema examinations. Thermoluminescent dosimeters were place in a phantom to calculate the depth-to-skin conversion coefficient needed for dose estimation at the average embryo depth in patients. Barium enema examinations were performed in 20 women of childbearing age with diagnostic problems demanding longer fluoroscopy times. Doses at 6 cm, the average embryo depth, were determined by measurements at the patients` skin followed by dose calculation at the site of interest. The range of doses estimated at embryo depth for patients was 1.9 to 8.2 cGy. The dose always exceeded 5 cGy when fluoroscopy time was longer than 7 minutes. The dose at the embryo depth never exceeded 10 cGy. This study indicates that fluoroscopy time should not exceed 7 minutes in childbearing-age female patients undergoing barium enema examinations. 6 refs., 1 fig., 2 tabs.

  13. Absorbed Gamma-Ray Doses due to Natural Radionuclides in Building Materials

    SciTech Connect

    Aguiar, Vitor A. P.; Medina, Nilberto H.; Moreira, Ramon H.; Silveira, Marcilei A. G.

    2010-05-21

    This work is devoted to the application of high-resolution gamma-ray spectrometry in the study of the effective dose coming from naturally occurring radionuclides, namely {sup 40}K, {sup 232}Th and {sup 238}U, present in building materials such as sand, cement, and granitic gravel. Four models were applied to estimate the effective dose and the hazard indices. The maximum estimated effective dose coming from the three reference rooms considered is 0.90(45) mSv/yr, and maximum internal hazard index is 0.77(24), both for the compact clay brick reference room. The principal gamma radiation sources are cement, sand and bricks.

  14. Determination of absorbed dose in water at the reference point d(r0, theta0) for an 192Ir HDR brachytherapy source using a Fricke system.

    PubMed

    Austerlitz, C; Mota, H C; Sempau, J; Benhabib, S M; Campos, D; Allison, R; DeAlmeida, C E; Zhu, D; Sibata, C H

    2008-12-01

    A ring-shaped Fricke device was developed to measure the absolute dose on the transverse bisector of a 192Ir high dose rate (HDR) source at 1 cm from its center in water, D(r0, theta0). It consists of a polymethylmethacrylate (PMMA) rod (axial axis) with a cylindrical cavity at its center to insert the 192Ir radioactive source. A ring cavity around the source with 1.5 mm thickness and 5 mm height is centered at 1 cm from the central axis of the source. This ring cavity is etched in a disk shaped base with 2.65 cm diameter and 0.90 cm thickness. The cavity has a wall around it 0.25 cm thick. This ring is filled with Fricke solution, sealed, and the whole assembly is immersed in water during irradiations. The device takes advantage of the cylindrical geometry to measure D(r0, theta0). Irradiations were performed with a Nucletron microselectron HDR unit loaded with an 192Ir Alpha Omega radioactive source. A Spectronic 1001 spectrophotometer was used to measure the optical absorbance using a 1 mL quartz cuvette with 1.00 cm light pathlength. The PENELOPE Monte Carlo code (MC) was utilized to simulate the Fricke device and the 192Ir Alpha Omega source in detail to calculate the perturbation introduced by the PMMA material. A NIST traceable calibrated well type ionization chamber was used to determine the air-kerma strength, and a published dose-rate constant was used to determine the dose rate at the reference point. The time to deliver 30.00 Gy to the reference point was calculated. This absorbed dose was then compared to the absorbed dose measured by the Fricke solution. Based on MC simulation, the PMMA of the Fricke device increases the D(r0, theta0) by 2.0%. Applying the corresponding correction factor, the D(r0, theta0) value assessed with the Fricke device agrees within 2.0% with the expected value with a total combined uncertainty of 3.43% (k=1). The Fricke device provides a promising method towards calibration of brachytherapy radiation sources in terms of D(r0

  15. Imaging of Absorbed Dose in Radiotherapy by a Polymer Gel Dosimeter

    NASA Astrophysics Data System (ADS)

    Vanossi, E.; Gambarini, G.; Carrara, M.; Mariani, M.; Negri, A.

    2008-06-01

    Optical imaging of polymer gel dosimeters in form of layers was investigated to enquire their reliability for in-phantom dose measurements in photon or thermal neutron fields. The obtained dose measurements were compared with those achieved by means of Fricke gel dosimeters. Reliability of Fricke gel dosimeters was confirmed, whereas it has been shown that a conspicuous improvement of the adopted polymer gel dosimeters is necessary.

  16. Polarization independent broadband metamaterial absorber based on tapered helical structure

    NASA Astrophysics Data System (ADS)

    Agarwal, Sajal; Prajapati, Y. K.; Singh, V.; Saini, J. P.

    2015-12-01

    This communication presents a tapered helical structure as absorber, made of unconventional material i.e. metamaterial. Modeling, analytical study and the optimization of the absorber have been done. Quad helical optimized structure gives almost unity absorption at 499 nm wavelength and gives the absorption more than 75% from 300 nm to 1650 nm which is a very wide operating region with, average absorbance of 91.32%. Whereas, triple helical structure gives 85% average absorbance with the operating range from 300 nm to 1350 nm. Also, it is analyzed that the presented structures are polarization independent and broadband. Comparison of the proposed quad helical absorber with the existing metamaterial absorbers is done and found it is most eligible.

  17. A multiband perfect absorber based on hyperbolic metamaterials

    PubMed Central

    Sreekanth, Kandammathe Valiyaveedu; ElKabbash, Mohamed; Alapan, Yunus; Rashed, Alireza R.; Gurkan, Umut A.; Strangi, Giuseppe

    2016-01-01

    In recent years, considerable research efforts have been focused on near-perfect and perfect light absorption using metamaterials spanning frequency ranges from microwaves to visible frequencies. This relatively young field is currently facing many challenges that hampers its possible practical applications. In this paper, we present grating coupled-hyperbolic metamaterials (GC-HMM) as multiband perfect absorber that can offer extremely high flexibility in engineering the properties of electromagnetic absorption. The fabricated GC-HMMs exhibit several highly desirable features for technological applications such as polarization independence, wide angle range, broad- and narrow- band modes, multiband perfect and near perfect absorption in the visible to near-IR and mid-IR spectral range. In addition, we report a direct application of the presented system as an absorption based plasmonic sensor with a record figure of merit for this class of sensors. PMID:27188789

  18. Evaluation of the breast absorbed dose distribution using the Fricke Xylenol Gel

    NASA Astrophysics Data System (ADS)

    Czelusniak, C.; Del Lama, L. S.; Moreira, M. V.; De Almeida, A.

    2010-11-01

    During a breast cancer radiotherapy treatment, several issues have to be taken into account, among them, hot spots, gradient of doses delivered over the breast, as well as in the lungs and the heart. The present work aims to apply the Fricke Xylenol Gel (FXG) dosimeter in the study of these issues, using a CCD camera to analyse the dose deposited distribution. Thus, the CCD was used to capture the images of different cuvettes that were filled with FXG and irradiated considering analogous setups employed in breast cancer radiotherapy treatments. Thereafter, these pictures where processed in a MatLab routine and the spatial dose distributions could be evaluated. These distributions were compared with the ones that were obtained from dedicated treatment planning's softwares. According to the results obtained, the FXG, allied with the CCD system, has shown to be a complementary tool in dosimetry, helping to prevent possible complications during breast cancer treatments.

  19. MONTE CARLO STUDY OF THE CARDIAC ABSORBED DOSE DURING X-RAY EXAMINATION OF AN ADULT PATIENT.

    PubMed

    Kadri, O; Manai, K; Alfuraih, A

    2016-12-01

    The computational voxel phantom 'High-Definition Reference Korean-Man (HDRK-Man)' was implemented into the Monte Carlo transport toolkit Geant4. The voxel model, adjusted to the Reference Korean Man, is 171 cm in height and 68 kg in weight and composed of ∼30 million voxels whose size is 1.981 × 1.981 × 2.0854 mm(3) The Geant4 code is then utilised to compute the dose conversion coefficients (DCCs) expressed in absorbed dose per air kerma free in air for >30 tissues and organs, including almost all organs required in the new recommendation of the ICRP 103, due to a broad parallel beam of monoenergetic photons impinging in antero-postero direction with energy ranging from 10 to 150 keV. The computed DCCs of different organs are found to be in good agreement with data published using other simulation codes. Also, the influence of patient size on DCC values was investigated for a representative body size of the adult Korean patient population. The study was performed using five different sizes covering the range of 0.8-1.2 magnification order of the original HDRK-Man. It focussed on the computation of DCC for the human heart. Moreover, the provided DCCs were used to present an analytical parameterisation for the calculation of the cardiac absorbed dose for any arbitrary X-ray spectrum and for those patient sizes. Thus, the present work can be considered as an enhancement of the continuous studies performed by medical physicist as part of quality control tests and radiation protection dosimetry.

  20. Quantification of absorbed doses to urine bladder depending on drinking water during radioiodine therapy to thyroid cancer patients: a clinical study using MIRDOSE3.

    PubMed

    Sabbir Ahmed, A S M; Demir, M; Yasar, D; Uslu, I

    2003-07-01

    The object of the study was to quantify the absorbed doses to urinary bladder using MIRDOSE3 (medical internal radiation dose package program) depending on drinking water after giving radioiodine dose to thyroid cancer patients. Twenty-nine female thyroid cancer patients (aged 40-60 years, mean 50 years) were selected. The therapeutic doses ranged from 3700 to 7400 MBq of 131I. The radioiodine uptake was measured at 1 cm distance from three organs (previously marked), the thyroid, thigh and stomach, by using a calibrated Eberline ESP-2 GM counter, with a special arrangement of each patient. Urine samples were collected every 12 h for first 72 h, and then every 24 h for the next 96 h. The individual biological half-life of excreted urine was calculated using individual effective half-life. Absorbed doses were calculated for an adult female phantom using the dynamic bladder model of MIRDOSE3 program in two phases: firstly, for different voiding intervals; and secondly, depending on individual drinking water. An average of 85% of the total dose passed through the urinary tract within the first 72 h, with a biological half-life of 28.5+/-0.747 h, and 9% for the next 96 h with a biological half life of 118.43+/-0.645 h. The voiding interval shows great impact on total absorbed dose to bladder and water supplementation needs to be intensified to reduce absorbed doses to bladder wall for the first 3 days.

  1. Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the PTB, Germany and the BIPM in 60Co gamma radiation

    NASA Astrophysics Data System (ADS)

    Kessler, C.; Burns, D. T.; Kapsch, R.-P.; Krauss, A.

    2016-01-01

    An indirect comparison has been made of the standards for absorbed dose to water in 60Co radiation of the Physikalisch-Technische Bundesanstalt, (PTB), Germany and of the Bureau International des Poids et Mesures (BIPM). The measurements at the BIPM were carried out in October 2015. The comparison result, based on the calibration coefficients for two transfer standards and evaluated as a ratio of the PTB and the BIPM standards for absorbed dose to water, is 0.9977 with a combined standard uncertainty of 3.8 × 10-3. The results are analysed and presented in terms of degrees of equivalence for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Reducing absorbed dose to eye lenses in head CT examinations: the effect of bismuth shielding.

    PubMed

    Ciarmatori, Alberto; Nocetti, L; Mistretta, G; Zambelli, G; Costi, T

    2016-06-01

    The eye lens is considered to be among the most radiosensitive human tissues. Brain CT scans may unnecessarily expose it to radiation even if the area of clinical interest is far from the eyes. The aim of this study is to implement a bismuth eye lens shielding system for Head-CT acquisitions in these cases. The study is focused on the assessment of the dosimetric characteristics of the shielding system as well as on its effect on image quality. The shielding system was tested in two set-ups which differ for distance ("contact" and "4 cm" Set up respectively). Scans were performed on a CTDI phantom and an anthropomorphic phantom. A reference set up without shielding system was acquired to establish a baseline. Image quality was assessed by signal (not HU converted), noise and contrast-to-noise ratio (CNR) evaluation. The overall dose reduction was evaluated by measuring the CTDIvol while the eye lens dose reduction was assessed by placing thermoluminescent dosimeters (TLDs) on an anthropomorphic phantom. The image quality analysis exhibits the presence of an artefact that mildly increases the CT number up to 3 cm below the shielding system. Below the artefact, the difference of the Signal and the CNR are negligible between the three different set-ups. Regarding the CTDI, the analysis demonstrates a decrease by almost 12 % (in the "contact" set-up) and 9 % (in the "4 cm" set-up). TLD measurements exhibit an eye lens dose reduction by 28.5 ± 5 and 21.1 ± 5 % respectively at the "contact" and the "4 cm" distance. No relevant artefact was found and image quality was not affected by the shielding system. Significant dose reductions were measured. These features make the shielding set-up useful for clinical implementation in both studied positions.

  3. Tumoral fibrosis effect on the radiation absorbed dose of (177)Lu-Tyr(3)-octreotate and (177)Lu-Tyr(3)-octreotate conjugated to gold nanoparticles.

    PubMed

    Azorín-Vega, E P; Zambrano-Ramírez, O D; Rojas-Calderón, E L; Ocampo-García, B E; Ferro-Flores, G

    2015-06-01

    The aim of this work was to evaluate the tumoral fibrosis effect on the radiation absorbed dose of the radiopharmaceuticals (177)Lu-Tyr(3)-octreotate (monomeric) and (177)Lu-Tyr(3)-octreotate-gold nanoparticles (multimeric) using an experimental HeLa cells tumoral model and the Monte Carlo PENELOPE code. Experimental and computer micro-environment models with or without fibrosis were constructed. Results showed that fibrosis increases up to 33% the tumor radiation absorbed dose, although the major effect on the dose was produced by the type of radiopharmaceutical (112Gy-multimeric vs. 43Gy-monomeric).

  4. [An investigation of ionizing radiation dose in a manufacturing enterprise of ion-absorbing type rare earth ore].

    PubMed

    Zhang, W F; Tang, S H; Tan, Q; Liu, Y M

    2016-08-20

    Objective: To investigate radioactive source term dose monitoring and estimation results in a manufacturing enterprise of ion-absorbing type rare earth ore and the possible ionizing radiation dose received by its workers. Methods: Ionizing radiation monitoring data of the posts in the control area and supervised area of workplace were collected, and the annual average effective dose directly estimated or estimated using formulas was evaluated and analyzed. Results: In the control area and supervised area of the workplace for this rare earth ore, α surface contamination activity had a maximum value of 0.35 Bq/cm(2) and a minimum value of 0.01 Bq/cm(2); β radioactive surface contamination activity had a maximum value of 18.8 Bq/cm(2) and a minimum value of 0.22 Bq/cm(2). In 14 monitoring points in the workplace, the maximum value of the annual average effective dose of occupational exposure was 1.641 mSv/a, which did not exceed the authorized limit for workers (5 mSv/a) , but exceeded the authorized limit for general personnel (0.25 mSv/a) . The radionuclide specific activity of ionic mixed rare earth oxides was determined to be 0.9. Conclusion: The annual average effective dose of occupational exposure in this enterprise does not exceed the authorized limit for workers, but it exceeds the authorized limit for general personnel. We should pay attention to the focus of the radiation process, especially for public works radiation.

  5. Calculation of absorbed dose and biological effectiveness from photonuclear reactions in a bremsstrahlung beam of end point 50 MeV.

    PubMed

    Gudowska, I; Brahme, A; Andreo, P; Gudowski, W; Kierkegaard, J

    1999-09-01

    The absorbed dose due to photonuclear reactions in soft tissue, lung, breast, adipose tissue and cortical bone has been evaluated for a scanned bremsstrahlung beam of end point 50 MeV from a racetrack accelerator. The Monte Carlo code MCNP4B was used to determine the photon source spectrum from the bremsstrahlung target and to simulate the transport of photons through the treatment head and the patient. Photonuclear particle production in tissue was calculated numerically using the energy distributions of photons derived from the Monte Carlo simulations. The transport of photoneutrons in the patient and the photoneutron absorbed dose to tissue were determined using MCNP4B; the absorbed dose due to charged photonuclear particles was calculated numerically assuming total energy absorption in tissue voxels of 1 cm3. The photonuclear absorbed dose to soft tissue, lung, breast and adipose tissue is about (0.11-0.12)+/-0.05% of the maximum photon dose at a depth of 5.5 cm. The absorbed dose to cortical bone is about 45% larger than that to soft tissue. If the contributions from all photoparticles (n, p, 3He and 4He particles and recoils of the residual nuclei) produced in the soft tissue and the accelerator, and from positron radiation and gammas due to induced radioactivity and excited states of the nuclei, are taken into account the total photonuclear absorbed dose delivered to soft tissue is about 0.15+/-0.08% of the maximum photon dose. It has been estimated that the RBE of the photon beam of 50 MV acceleration potential is approximately 2% higher than that of conventional 60Co radiation.

  6. A radiochromic folm dosimeter for gamma radiation in the absorbed-dose range 0.1-10 kGy

    NASA Astrophysics Data System (ADS)

    Khan, Hasan M.; Farahani, Mahnaz; William L., McLaughlin

    A commercially available leuco-dye film (FWT-63-02), having a thickness of 0.55 mm, has been investigated spectrophotometrically for its characteristics as a radiochromic dosimeter and for its potential use in food-irradiation applications. The γ-ray irradiation of the nearly colorless, transparent film induces blue color with an absorption maximum at 600 nm. The increase in absorbance at 600 nm per unit thickness of film (Δ A mm -1) is linear with dose in the dose range up to 8 kGy, with a slope of 0.91 mm -1·kGy -1. After a modest additional increase during the first day following irradiation, the radiation-induced color is stable when stored at room temperature at least for 5 weeks. The response slope is 16% higher when stored at 60°C, however, after the initial 1-day increase it is stable for several weeks when stored at that temperature. The response of the dosimeter is independent of dose rate in the range 0.5-170 Gy min -1.

  7. A dosimetric evaluation of tissue equivalent phantom prepared using 270 Bloom gelatin for absorbed dose imaging in Gamma knife radiosurgery

    NASA Astrophysics Data System (ADS)

    Cavinato, C. C.; Rodrigues, O., Jr.; Cervantes, J. H.; Rabbani, S. R.; Campos, L. L.

    2009-05-01

    Tissue equivalent gel phantoms have been widely studied in radiation therapy for both relative and reference dosimetry. A Fricke xylenol gel (FXG) spherical phantom was evaluated by means of magnetic resonance image method (MRI) to measure absorbed dose distribution resulted from gamma knife irradiation. The FXG phantom was prepared using 270 Bloom gelatin. The gelatin is a tissue equivalent material, of easy preparation, can be used to mold phantoms into different shapes and volumes, is commercially available and inexpensive. The results show that the Fricke gel phantom prepared with 270 Bloom gelatin satisfy the requirements to be used for the quality control in stereotactic radiosurgery using Gamma Knife technique and may constitute one more option of dosimeter in radiation therapy applications.

  8. Enhancement mechanism of the additional absorbent on the absorption of the absorbing composite using a type-based mixing rule

    NASA Astrophysics Data System (ADS)

    Xu, Yonggang; Yuan, Liming; Zhang, Deyuan

    2016-04-01

    A silicone rubber composite filled with carbonyl iron particles and four different carbonous materials (carbon black, graphite, carbon fiber or multi-walled carbon nanotubes) was prepared using a two-roller mixture. The complex permittivity and permeability were measured using a vector network analyzer at the frequency of 2-18 GHz. Then a type-based mixing rule based on the dielectric absorbent and magnetic absorbent was proposed to reveal the enhancing mechanism on the permittivity and permeability. The enforcement effect lies in the decreased percolation threshold and the changing pending parameter as the carbonous materials were added. The reflection loss (RL) result showed the added carbonous materials enhanced the absorption in the lower frequency range, the RL decrement value being about 2 dB at 4-5 GHz with a thickness of 1 mm. All the added carbonous materials reinforced the shielding effectiveness (SE) of the composites. The maximum increment value of the SE was about 3.23 dB at 0.5 mm and 4.65 dB at 1 mm, respectively. The added carbonous materials could be effective additives for enforcing the absorption and shielding property of the absorbers.

  9. Assessment of absorbed dose to thyroid, parotid and ovaries in patients undergoing Gamma Knife radiosurgery

    NASA Astrophysics Data System (ADS)

    Hasanzadeh, H.; Sharafi, A.; Allah Verdi, M.; Nikoofar, A.

    2006-09-01

    Stereotactic radiosurgery was originally introduced by Lars Leksell in 1951. This treatment refers to the noninvasive destruction of an intracranial target localized stereotactically. The purpose of this study was to identify the dose delivered to the parotid, ovaries, testis and thyroid glands during the Gamma Knife radiosurgery procedure. A three-dimensional, anthropomorphic phantom was developed using natural human bone, paraffin and sodium chloride as the equivalent tissue. The phantom consisted of a thorax, head and neck and hip. In the natural places of the thyroid, parotid (bilateral sides) and ovaries (midline), some cavities were made to place TLDs. Three TLDs were inserted in a batch with 1 cm space between the TLDs and each batch was inserted into a single cavity. The final depth of TLDs was 3 cm from the surface for parotid and thyroid and was 15 cm for the ovaries. Similar batches were placed superficially on the phantom. The phantom was gamma irradiated using a Leksell model C Gamma Knife unit. Subsequently, the same batches were placed superficially over the thyroid, parotid, testis and ovaries in 30 patients (15 men and 15 women) who were undergoing radiosurgery treatment for brain tumours. The mean dosage for treating these patients was 14.48 ± 3.06 Gy (10.5-24 Gy) to a mean tumour volume of 12.30 ± 9.66 cc (0.27-42.4 cc) in the 50% isodose curve. There was no significant difference between the superficial and deep batches in the phantom studies (P-value < 0.05). The mean delivered doses to the parotid, thyroid, ovaries and testis in human subjects were 21.6 ± 15.1 cGy, 9.15 ± 3.89 cGy, 0.47 ± 0.3 cGy and 0.53 ± 0.31 cGy, respectively. The data can be used in making decisions for special clinical situations such as treating pregnant patients or young patients with benign lesions who need radiosurgery for eradication of brain tumours.

  10. Assessment of absorbed dose to thyroid, parotid and ovaries in patients undergoing Gamma Knife radiosurgery.

    PubMed

    Hasanzadeh, H; Sharafi, A; Allah Verdi, M; Nikoofar, A

    2006-09-07

    Stereotactic radiosurgery was originally introduced by Lars Leksell in 1951. This treatment refers to the noninvasive destruction of an intracranial target localized stereotactically. The purpose of this study was to identify the dose delivered to the parotid, ovaries, testis and thyroid glands during the Gamma Knife radiosurgery procedure. A three-dimensional, anthropomorphic phantom was developed using natural human bone, paraffin and sodium chloride as the equivalent tissue. The phantom consisted of a thorax, head and neck and hip. In the natural places of the thyroid, parotid (bilateral sides) and ovaries (midline), some cavities were made to place TLDs. Three TLDs were inserted in a batch with 1 cm space between the TLDs and each batch was inserted into a single cavity. The final depth of TLDs was 3 cm from the surface for parotid and thyroid and was 15 cm for the ovaries. Similar batches were placed superficially on the phantom. The phantom was gamma irradiated using a Leksell model C Gamma Knife unit. Subsequently, the same batches were placed superficially over the thyroid, parotid, testis and ovaries in 30 patients (15 men and 15 women) who were undergoing radiosurgery treatment for brain tumours. The mean dosage for treating these patients was 14.48 +/- 3.06 Gy (10.5-24 Gy) to a mean tumour volume of 12.30 +/- 9.66 cc (0.27-42.4 cc) in the 50% isodose curve. There was no significant difference between the superficial and deep batches in the phantom studies (P-value < 0.05). The mean delivered doses to the parotid, thyroid, ovaries and testis in human subjects were 21.6 +/- 15.1 cGy, 9.15 +/- 3.89 cGy, 0.47 +/- 0.3 cGy and 0.53 +/- 0.31 cGy, respectively. The data can be used in making decisions for special clinical situations such as treating pregnant patients or young patients with benign lesions who need radiosurgery for eradication of brain tumours.

  11. Broadband terahertz metamaterial absorber based on sectional asymmetric structures

    PubMed Central

    Gong, Cheng; Zhan, Mingzhou; Yang, Jing; Wang, Zhigang; Liu, Haitao; Zhao, Yuejin; Liu, Weiwei

    2016-01-01

    We suggest and demonstrate the concept and design of sectional asymmetric structures which can manipulate the metamaterial absorber’s working bandwidth with maintaining the other inherent advantages. As an example, a broadband terahertz perfect absorber is designed to confirm its effectiveness. The absorber’s each cell integrates four sectional asymmetric rings, and the entire structure composed of Au and Si3N4 is only 1.9 μm thick. The simulation results show the bandwidth with absorptivity being larger than 90% is extended by about 2.8 times comparing with the conventional square ring absorber. The composable small cell, ultra-thin, and broadband absorption with polarization and incident angle insensitivity will make the absorber suitable for the applications of focal plane array terahertz imaging. PMID:27571941

  12. Broadband terahertz metamaterial absorber based on sectional asymmetric structures

    NASA Astrophysics Data System (ADS)

    Gong, Cheng; Zhan, Mingzhou; Yang, Jing; Wang, Zhigang; Liu, Haitao; Zhao, Yuejin; Liu, Weiwei

    2016-08-01

    We suggest and demonstrate the concept and design of sectional asymmetric structures which can manipulate the metamaterial absorber’s working bandwidth with maintaining the other inherent advantages. As an example, a broadband terahertz perfect absorber is designed to confirm its effectiveness. The absorber’s each cell integrates four sectional asymmetric rings, and the entire structure composed of Au and Si3N4 is only 1.9 μm thick. The simulation results show the bandwidth with absorptivity being larger than 90% is extended by about 2.8 times comparing with the conventional square ring absorber. The composable small cell, ultra-thin, and broadband absorption with polarization and incident angle insensitivity will make the absorber suitable for the applications of focal plane array terahertz imaging.

  13. An Omnidirectional Polarization Detector Based on a Metamaterial Absorber.

    PubMed

    Zhang, Binzhen; Zhang, Yong; Duan, Junping; Zhang, Wendong; Wang, Wanjun

    2016-07-23

    The theory, design, simulation, fabrication, and performance of an omnidirectional polarization detector (PD) with two resonances located in the X and Ka ranges based on a metamaterial absorber (MMA) are presented in this paper. The sandwich structure of PD is composed of 0.1 μm periodic "I" shaped patches on the metasurface, a dielectric of 200 μm FR-4 on the interlayer, and a 0.3 μm copper film on the substrate. PD absorptivity is first used to reflect and describe the polarization of the incident wave. The numerical results, derived from the standard full wave finite integration technology (FIT) of CST 2015, indicates that the designed PD shows polarization sensitivity at all incidence angles. The effects on absorptivity produced by the incidence angles, polarization angles, and materials are investigated. The amplitude of absorptivity change caused by polarization reaches 99.802%. A laser ablation process is adopted to prepare the designed PD on a FR-4 board coated with copper on the double plane with a thickness that was 1/93 and 1/48 of wavelength at a resonance frequency of 16.055 GHz and 30.9 GHz, respectively. The sample test results verify the designed PD excellent detectability on the polarization of the incident waves. The proposed PD, which greatly enriches the applications of metamaterials in bolometers, thermal images, stealth materials, microstructure measurements, and electromagnetic devices, is easy to mass produce and market because of its strong detectability, ultrathin thickness, effective cost, and convenient process.

  14. An Omnidirectional Polarization Detector Based on a Metamaterial Absorber

    PubMed Central

    Zhang, Binzhen; Zhang, Yong; Duan, Junping; Zhang, Wendong; Wang, Wanjun

    2016-01-01

    The theory, design, simulation, fabrication, and performance of an omnidirectional polarization detector (PD) with two resonances located in the X and Ka ranges based on a metamaterial absorber (MMA) are presented in this paper. The sandwich structure of PD is composed of 0.1 μm periodic “I” shaped patches on the metasurface, a dielectric of 200 μm FR-4 on the interlayer, and a 0.3 μm copper film on the substrate. PD absorptivity is first used to reflect and describe the polarization of the incident wave. The numerical results, derived from the standard full wave finite integration technology (FIT) of CST 2015, indicates that the designed PD shows polarization sensitivity at all incidence angles. The effects on absorptivity produced by the incidence angles, polarization angles, and materials are investigated. The amplitude of absorptivity change caused by polarization reaches 99.802%. A laser ablation process is adopted to prepare the designed PD on a FR-4 board coated with copper on the double plane with a thickness that was 1/93 and 1/48 of wavelength at a resonance frequency of 16.055 GHz and 30.9 GHz, respectively. The sample test results verify the designed PD excellent detectability on the polarization of the incident waves. The proposed PD, which greatly enriches the applications of metamaterials in bolometers, thermal images, stealth materials, microstructure measurements, and electromagnetic devices, is easy to mass produce and market because of its strong detectability, ultrathin thickness, effective cost, and convenient process. PMID:27455280

  15. Degradation and decoloration of textiles wastewater by electron beam irradiation: Effect of energy, current and absorbed dose

    SciTech Connect

    Bakar, Khomsaton Abu; Zulkafli,; Hashim, Siti A'aisah; Ahmad, Pauzi

    2014-09-03

    In this study, electron beam accelerator (EB) was used to treat textiles wastewater from Rawang Industrial Park, Selangor. The objectives were to determine effective energy, beam current and absorbed dose required for decoloration and degradation of the textiles effluent. The textiles effluent was irradiated in a batch with various energy of 1MeV to 3MeV at constant beam current of 30mA. It was observed that removal of color and COD increases with higher beam energy. The EB energy of 1MeV effectively to removed 58% color and 19% COD. For textile effluent sample irradiated at fix energy of 1MeV and 3Mev but at different beam current 10mA, 20mA and 30mA. It was observed that removal of color and COD increases with the increased of beam current at each energy. However removal of color was significantly better at 1Mev as compared to 3Mev. In the case of textiles effluent, irradiated at doses of 17, 20,25,30, 35, 100 and 200kGy using 30 kW power of EB (1Mev, 30mA), results shows removal of BOD{sub 5}, COD and color were in the range 9%-33%, 14%-38% and 43%-78% respectively.

  16. Degradation and decoloration of textiles wastewater by electron beam irradiation: Effect of energy, current and absorbed dose

    NASA Astrophysics Data System (ADS)

    Bakar, Khomsaton Abu; Ahmad, Pauzi; Zulkafli, Hashim, Siti A'aisah

    2014-09-01

    In this study, electron beam accelerator (EB) was used to treat textiles wastewater from Rawang Industrial Park, Selangor. The objectives were to determine effective energy, beam current and absorbed dose required for decoloration and degradation of the textiles effluent. The textiles effluent was irradiated in a batch with various energy of 1MeV to 3MeV at constant beam current of 30mA. It was observed that removal of color and COD increases with higher beam energy. The EB energy of 1MeV effectively to removed 58% color and 19% COD. For textile effluent sample irradiated at fix energy of 1MeV and 3Mev but at different beam current 10mA, 20mA and 30mA. It was observed that removal of color and COD increases with the increased of beam current at each energy. However removal of color was significantly better at 1Mev as compared to 3Mev. In the case of textiles effluent, irradiated at doses of 17, 20,25,30, 35, 100 and 200kGy using 30 kW power of EB (1Mev, 30mA), results shows removal of BOD5, COD and color were in the range 9%-33%, 14%-38% and 43%-78% respectively.

  17. Monte Carlo estimation of radiation dose in organs of female and male adult phantoms due to FDG-F18 absorbed in the lungs

    NASA Astrophysics Data System (ADS)

    Belinato, Walmir; Santos, William S.; Silva, Rogério M. V.; Souza, Divanizia N.

    2014-03-01

    The determination of dose conversion factors (S values) for the radionuclide fluorodeoxyglucose (18F-FDG) absorbed in the lungs during a positron emission tomography (PET) procedure was calculated using the Monte Carlo method (MCNPX version 2.7.0). For the obtained dose conversion factors of interest, it was considered a uniform absorption of radiopharmaceutical by the lung of a healthy adult human. The spectrum of fluorine was introduced in the input data file for the simulation. The simulation took place in two adult phantoms of both sexes, based on polygon mesh surfaces called FASH and MASH with anatomy and posture according to ICRP 89. The S values for the 22 internal organs/tissues, chosen from ICRP No. 110, for the FASH and MASH phantoms were compared with the results obtained from a MIRD V phantoms called ADAM and EVA used by the Committee on Medical Internal Radiation Dose (MIRD). We observed variation of more than 100% in S values due to structural anatomical differences in the internal organs of the MASH and FASH phantoms compared to the mathematical phantom.

  18. Angular distributions of absorbed dose of Bremsstrahlung and secondary electrons induced by 18-, 28- and 38-MeV electron beams in thick targets.

    PubMed

    Takada, Masashi; Kosako, Kazuaki; Oishi, Koji; Nakamura, Takashi; Sato, Kouichi; Kamiyama, Takashi; Kiyanagi, Yoshiaki

    2013-03-01

    Angular distributions of absorbed dose of Bremsstrahlung photons and secondary electrons at a wide range of emission angles from 0 to 135°, were experimentally obtained using an ion chamber with a 0.6 cm(3) air volume covered with or without a build-up cap. The Bremsstrahlung photons and electrons were produced by 18-, 28- and 38-MeV electron beams bombarding tungsten, copper, aluminium and carbon targets. The absorbed doses were also calculated from simulated photon and electron energy spectra by multiplying simulated response functions of the ion chambers, simulated with the MCNPX code. Calculated-to-experimental (C/E) dose ratios obtained are from 0.70 to 1.57 for high-Z targets of W and Cu, from 15 to 135° and the C/E range from 0.6 to 1.4 at 0°; however, the values of C/E for low-Z targets of Al and C are from 0.5 to 1.8 from 0 to 135°. Angular distributions at the forward angles decrease with increasing angles; on the other hand, the angular distributions at the backward angles depend on the target species. The dependences of absorbed doses on electron energy and target thickness were compared between the measured and simulated results. The attenuation profiles of absorbed doses of Bremsstrahlung beams at 0, 30 and 135° were also measured.

  19. [Irradiation of lymphogranulomatosis patients with large fields of complex configuration, calculating absorbed doses by microcomputer].

    PubMed

    Belyĭ, E K; Miasnikov, A A; Mendeleev, I M

    1985-01-01

    The authors demonstrated advantages of irradiating lymphogranulomatosis patients with large fields of complex configuration. The use of computer eliminates the difficulties of dosage calculation. Application for these purposes of the 15 VUMS-28 unit based on the microcomputer "Elektronika-60" is suggested. Algorithm of the dosage calculation program is presented. The program is drawn up according to the GOST so that it can be used by other institutions concerned.

  20. Semiconductor meta-surface based perfect light absorber.

    PubMed

    Liu, Guiqiang; Nie, Yiyou; Fu, Guolan; Liu, Xiaoshan; Liu, Yi; Tang, Li; Liu, Zhengqi

    2017-04-21

    We numerically proposed and demonstrated a semiconductor meta-surface light absorber, which consists of a silicon patches array on a silicon thin-film and an opaque silver substrate. The Mie resonances of the silicon patches and the fundamental cavity mode of the ultra-thin silicon film couple strongly to the incident optical field, leading to a multi-band perfect absorption. The maximal absorption is above 99.5% and the absorption is polarization-independent. Moreover, the absorption behavior is scalable in the frequency region via tuning the structural parameters. These features hold the absorber platform with wide applications in optoelectronics such as hot-electron excitation and photo-detection.

  1. Microwave metamaterial absorber based on multiple square ring structures

    NASA Astrophysics Data System (ADS)

    Zhou, Weicheng; Wang, Pinghe; Wang, Nan; Jiang, Wei; Dong, Xiaochun; Hu, Song

    2015-11-01

    In this paper, we report the design, analysis, and simulation of quintuple-band metamaterial absorber (MMA) in the microwave region. The absorber is constructed of a delicate periodic patterned structures and a metallic background plane, separated by a dielectric substrate. By manipulating the periodic patterned structures, high absorption can be obtained at five specific resonance frequencies. Moreover, the significantly high absorptions of quintuple-peaks are persistent with polarization independence, and the influence of angle of incidence for both TE and TM modes was also elucidated. For explaining the absorption mechanism of proposed structures, the electric and magnetic field distributions and resistance matching principal were given. Importantly, the design idea has the ability to be extended to other frequencies, like terahertz, infrared and optical frequencies.

  2. Calculation of the absorbed dose for the overexposed patients at the JCO criticality accident in Tokai-mura.

    PubMed

    Ishigure, N; Endo, A; Yamaguchi, Y; Kawachi, K

    2001-09-01

    The doses for the overexposed patients were estimated by the measurement result of specific activity of 24Na in blood. The present method is almost based on documents of the International Atomic Energy Agency (IAEA) and the Oak Ridge National Laboratory. The neutron energy spectrum obtained using the ANISN code (Multigroup One-Dimensional Discrete Ordinates Transport Code System with Anisotropic Scattering) was assumed. The values in ICRP Publication 74 were applied for the doses in each organ per unit neutron fluence. Gamma-ray dose was indirectly estimated based on (a) the result of environmental monitoring around the accident site and (b) a graph in IAEA manual, which gives the kerma ratio of neutrons and gamma-rays as a function of the critical volume or the atomic ratio of hydrogen to 235U. The estimated neutron doses were 5.4 Gy for patient A. 2.9 Gy for patient B and 0.81 Gy for patient C. The estimated gamma-ray doses were 8.5 or 13 Gy for patient A, 4.5 or 6.9 Gy for patient B, and 1.3 or 2.0 Gy for patient C.

  3. SU-E-T-516: Measurement of the Absorbed Dose Rate in Water Under Reference Conditions in a CyberKnife Unit

    SciTech Connect

    Aragon-Martinez, N; Hernandez-Guzman, A; Gomez-Munoz, A; Massillon-JL, G

    2014-06-01

    Purpose: This paper aims to measure the absorbed-dose-rate in a CyberKnife unit reference-field (6cm diameter) using three ionization chambers (IC) following the new IAEA/AAPM formalism and Gafchromic film (MD-V3-55 and EBT3) protocol according to our work reported previously. Methods: The absorbed-dose-rates were measured at 90cm and 70cm SSD in a 10cmx10cm field and at 70cm SSD in a 5.4cmx5.4cm equivalent to 6cm diameter field using a linac Varian iX. All measurements were performed at 10cm depth in water. The correction factors that account for the difference between the IC response on the reference field and the CyberKnife reference field, k-(Q-msr,Q)^(f-msr,f-ref), were evaluated and Gafchromic film were calibrated using the results obtained above. Under the CyberKnife reference conditions, the factors were used to measure the absorbed-dose-rate with IC according to the new formalism and the calibrated film was irradiated in water. The film calibration curve was used to evaluate the absorbed-dose-rate in the CyberKnife unit. Results: Difference up to 2.56% is observed between dose-rate measured with IC in the reference 10cmx10cm field, depending where the chamber was calibrated, which was not reflected in the correction factor k-(Q-msr,Q)^(f-msr,f-ref ) where variations of ~0.15%-0.5% were obtained. Within measurements uncertainties, maximum difference of 1.8% on the absorbed-dose-rate in the CyberKnife reference field is observed between all IC and the films Conclusion: Absorbed-dose-rate to water was measured in a CyberKnife reference field with acceptable accuracy (combined uncertainties ~1.32%-1.73%, k=1) using three IC and films. The MD-V3-55 film as well as the new IAEA/AAPM formalism can be considered as a suitable dosimetric method to measure absorbed-dose-rate to water in small and non-standard CyberKnife fields used in clinical treatments However, the EBT3 film is not appropriated due to the high uncertainty provided (combined uncertainty ~9%, k=1

  4. The effect of systematic set-up deviations on the absorbed dose distribution for left-sided breast cancer treated with respiratory gating

    NASA Astrophysics Data System (ADS)

    Edvardsson, A.; Ceberg, S.

    2013-06-01

    The aim of this study was 1) to investigate interfraction set-up uncertainties for patients treated with respiratory gating for left-sided breast cancer, 2) to investigate the effect of the inter-fraction set-up on the absorbed dose-distribution for the target and organs at risk (OARs) and 3) optimize the set-up correction strategy. By acquiring multiple set-up images the systematic set-up deviation was evaluated. The effect of the systematic set-up deviation on the absorbed dose distribution was evaluated by 1) simulation in the treatment planning system and 2) measurements with a biplanar diode array. The set-up deviations could be decreased using a no action level correction strategy. Not using the clinically implemented adaptive maximum likelihood factor for the gating patients resulted in better set-up. When the uncorrected set-up deviations were simulated the average mean absorbed dose was increased from 1.38 to 2.21 Gy for the heart, 4.17 to 8.86 Gy to the left anterior descending coronary artery and 5.80 to 7.64 Gy to the left lung. Respiratory gating can induce systematic set-up deviations which would result in increased mean absorbed dose to the OARs if not corrected for and should therefore be corrected for by an appropriate correction strategy.

  5. Transfer of the UK absorbed dose primary standard for photon beams from the research linac to the clinical linac at NPL

    NASA Astrophysics Data System (ADS)

    Pearce, J. A. D.; Shipley, D. R.; Duane, S.

    2011-10-01

    An Elekta Synergy clinical linac facility is now in routine use at the National Physical Laboratory (NPL). For the purpose of therapy-level dosimetry, this has replaced the NPL research linac, which is over 40 years old, and in which the NPL absorbed dose primary standard for high-energy photons was established. This standard has been disseminated to clinical beams by interpolation of the calibration factor as a function of tissue phantom ratio TPR20/10. In this work the absorbed dose standard has been commissioned in all the beams produced by the Elekta Synergy linac. Reference standard ionization chambers have been calibrated in terms of absorbed dose to graphite and this calibration has been converted to one in terms of absorbed dose to water. The results have been combined with the calibration in 60Co γ-rays to obtain measured values for the quality-dependent correction, kQ, for these reference standard chambers used in the Elekta beams. The resulting data are consistent with the interpolated kQ to within 0.4%, which is less than the combined standard uncertainty of kQ, 0.56%.

  6. Comparison of Accuracy in Calculation of Absorbed Dose to Patients Following Bone Scan with 99mTc-Marked Diphosphonates by Two Different Background Correction Methods

    PubMed Central

    Shahbazi-Gahrouei, Daryoush; Damoori, Mehri; Tavakoli, Mohammad Bagher; Moslehi, Masoud

    2016-01-01

    To improve the accuracy of the activity quantification and the image quality in scintigraphy, scatter correction is a vital procedure. The aim of this study is to compare the accuracy in calculation of absorbed dose to patients following bone scan with 99mTc-marked diphosphonates (99mTc-MDP) by two different methods of background correction in conjugate view method. This study involved 22 patients referring to the Nuclear Medicine Center of Shahid Chamran Hospital, Isfahan, Iran. After the injection of 99mTc-MDP, whole-body images from patients were acquired at 10, 60, 90, and 180 min. Organ activities were calculated using the conjugate view method by Buijs and conventional background correction. Finally, the absorbed dose was calculated using the Medical Internal Radiation Dosimetry (MIRD) technique. The results of this study showed that the absorbed dose per unit of injected activity (rad/mCi) ± standard deviation for pelvis bone, bladder, and kidneys by Buijs method was 0.19 ± 0.05, 0.08 ± 0.01, and 0.03 ± 0.01 and by conventional method was 0.13 ± 0.04, 0.08 ± 0.01, and 0.024 ± 0.01, respectively. This showed that Buijs background correction method had a high accuracy compared to conventional method for the estimated absorbed dose of bone and kidneys whereas, for the bladder, its accuracy was low. PMID:27014610

  7. Comparison of the NMIJ and the ARPANSA standards for absorbed dose to water in high-energy photon beams.

    PubMed

    Shimizu, M; Morishita, Y; Kato, M; Tanaka, T; Kurosawa, T; Takata, N; Saito, N; Ramanathan, G; Harty, P D; Oliver, C; Wright, T; Butler, D J

    2015-04-01

    The authors report the results of an indirect comparison of the standards of absorbed dose to water in high-energy photon beams from a clinical linac and (60)Co radiation beam performed between the National Metrology Institute of Japan (NMIJ) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). Three ionisation chambers were calibrated by the NMIJ in April and June 2013 and by the ARPANSA in May 2013. The average ratios of the calibration coefficients for the three ionisation chambers obtained by the NMIJ to those obtained by the ARPANSA were 0.9994, 1.0040 and 1.0045 for 6-, 10- and 15-MV (18 MV at the ARPANSA) high-energy photon beams, respectively. The relative standard uncertainty of the value was 7.2 × 10(-3). The ratio for (60)Co radiation was 0.9986(66), which is consistent with the results published in the key comparison of BIPM.RI(I)-K4.

  8. Photoluminescence-based quality control for thin film absorber layers of photovoltaic devices

    DOEpatents

    Repins, Ingrid L.; Kuciauskas, Darius

    2015-07-07

    A time-resolved photoluminescence-based system providing quality control during manufacture of thin film absorber layers for photovoltaic devices. The system includes a laser generating excitation beams and an optical fiber with an end used both for directing each excitation beam onto a thin film absorber layer and for collecting photoluminescence from the absorber layer. The system includes a processor determining a quality control parameter such as minority carrier lifetime of the thin film absorber layer based on the collected photoluminescence. In some implementations, the laser is a low power, pulsed diode laser having photon energy at least great enough to excite electron hole pairs in the thin film absorber layer. The scattered light may be filterable from the collected photoluminescence, and the system may include a dichroic beam splitter and a filter that transmit the photoluminescence and remove scattered laser light prior to delivery to a photodetector and a digital oscilloscope.

  9. Radiation Dosimetry for (177)Lu-PSMA I&T in Metastatic Castration-Resistant Prostate Cancer: Absorbed Dose in Normal Organs and Tumor Lesions.

    PubMed

    Okamoto, Shozo; Thieme, Anne; Allmann, Jakob; D'Alessandria, Calogero; Maurer, Tobias; Retz, Margitta; Tauber, Robert; Heck, Matthias M; Wester, Hans-Juergen; Tamaki, Nagara; Fendler, Wolfgang P; Herrmann, Ken; Pfob, Christian H; Scheidhauer, Klemens; Schwaiger, Markus; Ziegler, Sibylle; Eiber, Matthias

    2017-03-01

    Prostate-specific membrane antigen (PSMA)-targeted radioligand therapy is increasingly used in metastatic castration-resistant prostate cancer. We aimed to estimate the absorbed doses for normal organs and tumor lesions using (177)Lu-PSMA I&T (I&T is imaging and therapy) in patients undergoing up to 4 cycles of radioligand therapy. Results were compared with pretherapeutic Glu-NH-CO-NH-Lys-(Ahx)-[(68)Ga(HBEDCC)] ((68)Ga-PSMA-HBED-CC) PET. Methods: A total of 34 cycles in 18 patients were analyzed retrospectively. In 15 patients the first, in 9 the second, in 5 the third, and in 5 the fourth cycle was analyzed, respectively. Whole-body scintigraphy was performed at least between 30-120 min, 24 h, and 6-8 d after administration. Regions of interest covering the whole body, organs, and up to 4 tumor lesions were drawn. Organ and tumor masses were derived from pretherapeutic (68)Ga-PSMA-HBED-CC PET/CT. Absorbed doses for individual cycles were calculated using OLINDA/EXM. SUVs from pretherapeutic PET were compared with absorbed doses and with change of SUV. Results: The mean whole-body effective dose for all cycles was 0.06 ± 0.03 Sv/GBq. The mean absorbed organ doses were 0.72 ± 0.21 Gy/GBq for the kidneys; 0.12 ± 0.06 Gy/GBq for the liver; and 0.55 ± 0.14 Gy/GBq for the parotid, 0.64 ± 0.40 Gy/GBq for the submandibular, and 3.8 ± 1.4 Gy/GBq for the lacrimal glands. Absorbed organ doses were relatively constant among the 4 different cycles. Tumor lesions received a mean absorbed dose per cycle of 3.2 ± 2.6 Gy/GBq (range, 0.22-12 Gy/GBq). Doses to tumor lesions gradually decreased, with 3.5 ± 2.9 Gy/GBq for the first, 3.3 ± 2.5 Gy/GBq for the second, 2.7 ± 2.3 Gy/GBq for the third, and 2.4 ± 2.2 Gy/GBq for the fourth cycle. SUVs of pretherapeutic PET moderately correlated with absorbed dose (r = 0.44, P < 0.001 for SUVmax; r = 0.43, P < 0.001 for SUVmean) and moderately correlated with the change of SUV (r = 0.478, P < 0.001 for SUVmax, and r = 0.50, P < 0

  10. A graphite calorimeter for absolute measurements of absorbed dose to water: application in medium-energy x-ray filtered beams.

    PubMed

    Pinto, M; Pimpinella, M; Quini, M; D'Arienzo, M; Astefanoaei, I; Loreti, S; Guerra, A S

    2016-02-21

    The Italian National Institute of Ionizing Radiation Metrology (ENEA-INMRI) has designed and built a graphite calorimeter that, in a water phantom, has allowed the determination of the absorbed dose to water in medium-energy x-rays with generating voltages from 180 to 250 kV. The new standard is a miniaturized three-bodies calorimeter, with a disc-shaped core of 21 mm diameter and 2 mm thickness weighing 1.134 g, sealed in a PMMA waterproof envelope with air-evacuated gaps. The measured absorbed dose to graphite is converted into absorbed dose to water by means of an energy-dependent conversion factor obtained from Monte Carlo simulations. Heat-transfer correction factors were determined by FEM calculations. At a source-to-detector distance of 100 cm, a depth in water of 2 g cm(-2), and at a dose rate of about 0.15 Gy min(-1), results of calorimetric measurements of absorbed dose to water, D(w), were compared to experimental determinations, D wK, obtained via an ionization chamber calibrated in terms of air kerma, according to established dosimetry protocols. The combined standard uncertainty of D(w) and D(wK) were estimated as 1.9% and 1.7%, respectively. The two absorbed dose to water determinations were in agreement within 1%, well below the stated measurement uncertainties. Advancements are in progress to extend the measurement capability of the new in-water-phantom graphite calorimeter to other filtered medium-energy x-ray qualities and to reduce the D(w) uncertainty to around 1%. The new calorimeter represents the first implementation of in-water-phantom graphite calorimetry in the kilovoltage range and, allowing independent determinations of D(w), it will contribute to establish a robust system of absorbed dose to water primary standards for medium-energy x-ray beams.

  11. Microwave radiation absorbers based on corrugated composites with carbon fibers

    NASA Astrophysics Data System (ADS)

    Bychanok, D. S.; Plyushch, A. O.; Gorokhov, G. V.; Bychanok, U. S.; Kuzhir, P. P.; Maksimenko, S. A.

    2016-12-01

    A complex analysis of the dependence of the absorption coefficient of polymer composites with nonmagnetic carbon inclusions on the real and imaginary parts of the complex permittivity, as well as on the material thickness is performed in frequency range 26-37 GHz. The composites containing 0.2 wt % of carbon fibers have been obtained. It has been experimentally found that the corrugation of the composite surface substantially increases the absorbability (from 63 to 92% at a frequency of 30 GHz and a thickness of 4.50 mm) upon a decrease in the sample mass (by 28%). A method has been proposed for calculating the absorptance of corrugated composites in the microwave range.

  12. Experimental demonstration of a magnetically tunable ferrite based metamaterial absorber.

    PubMed

    Huang, Yongjun; Wen, Guangjun; Zhu, Weiren; Li, Jian; Si, Li-Ming; Premaratne, Malin

    2014-06-30

    We synthesize and systematically characterize a novel type of magnetically tunable metamaterial absorber (MA) by integrating ferrite as a substrate or superstrate into a conventional passive MA. The nearly perfect absorption and tunability of this device is studied both numerically and experimentally within X-band (8-12 GHz) in a rectangular waveguide setup. Our measurements clearly show that the resonant frequency of the MA can be shifted across a wide frequency band by continuous adjustment of a magnetic field acting on the ferrite. Moreover, the effects of substrate/superstrate's thickness on the MA's tunability are discussed. The insight gained from the generic analysis enabled us to design an optimized tunable MA with relative frequency tuning range as larger as 11.5% while keeping the absorptivity higher than 98.5%. Our results pave a path towards applications with tunable devices, such as selective thermal emitters, sensors, and bolometers.

  13. Carbon nanohorns-based nanofluids as direct sunlight absorbers.

    PubMed

    Sani, E; Barison, S; Pagura, C; Mercatelli, L; Sansoni, P; Fontani, D; Jafrancesco, D; Francini, F

    2010-03-01

    The optimization of the poor heat transfer characteristics of fluids conventionally employed in solar devices are at present one of the main topics for system efficiency and compactness. In the present work we investigated the optical and thermal properties of nanofluids consisting in aqueous suspensions of single wall carbon nanohorns. The characteristics of these nanofluids were evaluated in view of their use as sunlight absorber fluids in a solar device. The observed nanoparticle-induced differences in optical properties appeared promising, leading to a considerably higher sunlight absorption. We found that the thermal conductivity of the nanofluids was higher than pure water. Both these effects, together with the possible chemical functionalization of carbon nanohorns, make this new kind of nanofluids very interesting for increasing the overall efficiency of the sunlight exploiting device.

  14. Wavelength-dependent polarization absorber based on multi-cladding fiber with gold coating

    NASA Astrophysics Data System (ADS)

    Weng, Sijun; Pei, Li; Liu, Chao; Wang, Jianshuai; Li, Jing; Ning, Tigang

    2016-12-01

    The wavelength-dependent polarization absorber based on multi-cladding fiber (MCF) with surface plasmon resonance (SPR) is proposed and demonstrated. In order to obtain the SPR effect both in the x- and y- polarized direction, the MCF is polished in two sides. The numerical simulations show that the polarization absorber with the wavelengths of 980/1550 nm and 1310/1550 nm can be obtained by adjusting the parameters of dielectric layer. Each wavelength only transmits a single polarization in the wavelength-dependent polarization absorber, and the loss of unwanted polarized mode is more than 95 dB/cm. In addition, when the length of fiber is only 550 μm, the bandwidths of polarization absorber are 29 nm at 980 nm and 413 nm at 1550 nm, respectively; meanwhile, the bandwidth of 1310/1550 nm polarization absorber reaches 102 nm and 302 nm, respectively.

  15. Phantoms for diffuse optical imaging based on totally absorbing objects, part 2: experimental implementation

    NASA Astrophysics Data System (ADS)

    Martelli, Fabrizio; Ninni, Paola Di; Zaccanti, Giovanni; Contini, Davide; Spinelli, Lorenzo; Torricelli, Alessandro; Cubeddu, Rinaldo; Wabnitz, Heidrun; Mazurenka, Mikhail; Macdonald, Rainer; Sassaroli, Angelo; Pifferi, Antonio

    2014-07-01

    We present the experimental implementation and validation of a phantom for diffuse optical imaging based on totally absorbing objects for which, in the previous paper [J. Biomed. Opt. 18(6), 066014, (2013)], we have provided the basic theory. Totally absorbing objects have been manufactured as black polyvinyl chloride (PVC) cylinders and the phantom is a water dilution of intralipid-20% as the diffusive medium and India ink as the absorber, filled into a black scattering cell made of PVC. By means of time-domain measurements and of Monte Carlo simulations, we have shown the reliability, the accuracy, and the robustness of such a phantom in mimicking typical absorbing perturbations of diffuse optical imaging. In particular, we show that such a phantom can be used to generate any absorption perturbation by changing the volume and position of the totally absorbing inclusion.

  16. A 28-day repeated dose toxicity study of ultraviolet absorber 2-(2'-hydroxy-3',5'-di-tert-butylphenyl) benzotriazole in rats.

    PubMed

    Hirata-Koizumi, Mutsuko; Watari, Nobuaki; Mukai, Daisuke; Imai, Toshio; Hirose, Akihiko; Kamata, Eiichi; Ema, Makoto

    2007-01-01

    To examine the possible repeated-dose toxicity of an ultraviolet absorber, 2-(2'-hydroxy-3',5'-di-tert-butylphenyl)benzotriazole (HDBB), CD(SD)IGS rats were administered HDBB by gavage at a dose of 0 (vehicle: corn oil), 0.5, 2.5, 12.5, or 62.5 mg kg(-1) day(-1) for 28 days. At the completion of the administration period, a decrease in red blood cells, hemoglobin, and hematocrit was noted only in males at 2.5 mg/kg and more. Blood biochemical changes were noted at 0.5 mg/kg and more in males and at 62.5 mg/kg in females. Histopathologic changes were observed principally in the liver (vacuolar degeneration and hypertrophy of hepatocytes, bile duct proliferation, etc.) and in the heart (degeneration and hypertrophy of myocardium and cell infiltration). These changes were noted at 0.5 mg/kg and more in males and at 12.5 mg/kg and more in females. At higher doses, hypertrophy of tubular epithelium in the kidneys and diffuse follicular cell hyperplasia in the thyroids in both sexes and increased severity of basophilic tubules in the kidneys and extramedullary hematopoiesis in the spleen in males were also detected. After the 14-day recovery period, these changes mostly recovered in females but not in males. Based on these findings, no observed adverse effect level (NOAEL) was concluded to be less than 0.5 mg kg(-1) day(-1) in male rats and 2.5 mg kg(-1) day(-1) in female rats.

  17. Determination of absorbed dose to water around a clinical HDR {sup 192}Ir source using LiF:Mg,Ti TLDs demonstrates an LET dependence of detector response

    SciTech Connect

    Carlsson Tedgren, Aasa; Elia, Rouba; Hedtjaern, Haakan; Olsson, Sara; Alm Carlsson, Gudrun

    2012-02-15

    Purpose: Experimental radiation dosimetry with thermoluminescent dosimeters (TLDs), calibrated in a {sup 60}Co or megavoltage (MV) photon beam, is recommended by AAPM TG-43U1for verification of Monte Carlo calculated absorbed doses around brachytherapy sources. However, it has been shown by Carlsson Tedgren et al.[Med. Phys. 38, 5539-5550 (2011)] that for TLDs of LiF:Mg,Ti, detector response was 4% higher in a {sup 137}Cs beam than in a {sup 60}Co one. The aim of this work was to investigate if similar over-response exists when measuring absorbed dose to water around {sup 192}Ir sources, using LiF:Mg,Ti dosimeters calibrated in a 6 MV photon beam. Methods: LiF dosimeters were calibrated to measure absorbed dose to water in a 6 MV photon beam and used to measure absorbed dose to water at distances of 3, 5, and 7 cm from a clinical high dose rate (HDR) {sup 192}Ir source in a polymethylmethacrylate (PMMA) phantom. Measured values were compared to values of absorbed dose to water calculated using a treatment planning system (TPS) including corrections for the difference in energy absorption properties between calibration quality and the quality in the users'{sup 192}Ir beam and for the use of a PMMA phantom instead of the water phantom underlying dose calculations in the TPS. Results: Measured absorbed doses to water around the {sup 192}Ir source were overestimated by 5% compared to those calculated by the TPS. Corresponding absorbed doses to water measured in a previous work with lithium formate electron paramagnetic resonance (EPR) dosimeters by Antonovic et al. [Med. Phys. 36, 2236-2247 (2009)], using the same irradiation setup and calibration procedure as in this work, were 2% lower than those calculated by the TPS. The results obtained in the measurements in this work and those obtained using the EPR lithium formate dosimeters were, within the expanded (k = 2) uncertainty, in agreement with the values derived by the TPS. The discrepancy between the results using

  18. Design of mid-infrared ultra-wideband metallic absorber based on circuit theory

    NASA Astrophysics Data System (ADS)

    Arik, Kamalodin; Abdollahramezani, Sajjad; Farajollahi, Saeed; Khavasi, Amin; Rejaei, Behzad

    2016-12-01

    An ultra-broadband absorber of light is proposed by using periodic array of ultra-thin metallic ribbons on top of a lossless quarter-wavelength dielectric spacer placed on a metallic reflector. We propose a fully analytical circuit model for the structure, and then the absorber is duly designed based on the impedance matching concept. As a result, normalized bandwidth of 99.5% is realized by the proposed absorbing structure in mid-infrared regime. Performing a numerical optimization algorithm, we could also reach to normalized bandwidth of 103%.

  19. Detailed Distribution Map of Absorbed Dose Rate in Air in Tokatsu Area of Chiba Prefecture, Japan, Constructed by Car-Borne Survey 4 Years after the Fukushima Daiichi Nuclear Power Plant Accident.

    PubMed

    Inoue, Kazumasa; Arai, Moeko; Fujisawa, Makoto; Saito, Kyouko; Fukushi, Masahiro

    2017-01-01

    A car-borne survey was carried out in the northwestern, or Tokatsu, area of Chiba Prefecture, Japan, to make a detailed distribution map of absorbed dose rate in air four years after the Fukushima Daiichi Nuclear Power Plant accident. This area was chosen because it was the most heavily radionuclide contaminated part of Chiba Prefecture and it neighbors metropolitan Tokyo. Measurements were performed using a 3-in × 3-in NaI(Tl) scintillation spectrometer in June 2015. The survey route covered the whole Tokatsu area which includes six cities. A heterogeneous distribution of absorbed dose rate in air was observed on the dose distribution map. Especially, higher absorbed dose rates in air exceeding 80 nGy h-1 were observed along national roads constructed using high porosity asphalt, whereas lower absorbed dose rates in air were observed along local roads constructed using low porosity asphalt. The difference between these asphalt types resulted in a heterogeneous dose distribution in the Tokatsu area. The mean of the contribution ratio of artificial radionuclides to absorbed dose rate in air measured 4 years after the accident was 29% (9-50%) in the Tokatsu area. The maximum absorbed dose rate in air, 201 nGy h-1 was observed at Kashiwa City. Radiocesium was deposited in the upper 1 cm surface layer of the high porosity asphalt which was collected in Kashiwa City and the environmental half-life of the absorbed dose rate in air was estimated to be 1.7 years.

  20. Calorimetric determination of the absorbed dose to water for medium-energy x-rays with generating voltages from 70 to 280 kV.

    PubMed

    Krauss, A; Büermann, L; Kramer, H-M; Selbach, H-J

    2012-10-07

    For medium energy x-rays produced with tube voltages from 70 to 280 kV, the absorbed dose to water, D(w), has been determined by means of water calorimetry with relative standard uncertainties ranging from 0.45% to 0.98% at 280 and 70 kV. The results were confirmed by Monte Carlo calculations, in which the ratios of D(w) at 5 cm depth in a reference water phantom to the air kerma free in air, K(a), at the same point in space were compared to the corresponding ratios determined experimentally. The general agreement between measurement and calculation was better than 1%. These results confirm earlier investigations in which the absorbed dose to graphite was determined by means of a graphite extrapolation chamber. For the Monte Carlo calculations, an attempt was made to present a complete uncertainty budget, taking into account type B contributions also.

  1. Estimating radiation effective doses from whole body computed tomography scans based on U.S. soldier patient height and weight

    PubMed Central

    2011-01-01

    Background The purpose of this study is to explore how a patient's height and weight can be used to predict the effective dose to a reference phantom with similar height and weight from a chest abdomen pelvis computed tomography scan when machine-based parameters are unknown. Since machine-based scanning parameters can be misplaced or lost, a predictive model will enable the medical professional to quantify a patient's cumulative radiation dose. Methods One hundred mathematical phantoms of varying heights and weights were defined within an x-ray Monte Carlo based software code in order to calculate organ absorbed doses and effective doses from a chest abdomen pelvis scan. Regression analysis was used to develop an effective dose predictive model. The regression model was experimentally verified using anthropomorphic phantoms and validated against a real patient population. Results Estimates of the effective doses as calculated by the predictive model were within 10% of the estimates of the effective doses using experimentally measured absorbed doses within the anthropomorphic phantoms. Comparisons of the patient population effective doses show that the predictive model is within 33% of current methods of estimating effective dose using machine-based parameters. Conclusions A patient's height and weight can be used to estimate the effective dose from a chest abdomen pelvis computed tomography scan. The presented predictive model can be used interchangeably with current effective dose estimating techniques that rely on computed tomography machine-based techniques. PMID:22004072

  2. Depth absorbed dose and LET distributions of therapeutic {sup 1}H, {sup 4}He, {sup 7}Li, and {sup 12}C beams

    SciTech Connect

    Kempe, Johanna; Gudowska, Irena; Brahme, Anders

    2007-01-15

    The depth absorbed dose and LET (linear energy transfer) distribution of different ions of clinical interest such as {sup 1}H, {sup 4}He, {sup 7}Li, and {sup 12}C ions have been investigated using the Monte Carlo code SHIELD-HIT. The energies of the projectiles correspond to ranges in water and soft tissue of approximately 260 mm. The depth dose distributions of the primary particles and their secondaries have been calculated and separated with regard to their low and high LET components. A LET value below 10 eV/nm can generally be regarded as low LET and sparsely ionizing like electrons and photons. The high LET region may be assumed to start at 20 eV/nm where on average two double-strand breaks can be formed when crossing the periphery of a nucleosome, even though strictly speaking the LET limits are not sharp and ought to vary with the charge and mass of the ion. At the Bragg peak of a monoenergetic high energy proton beam, less than 3% of the total absorbed dose is comprised of high LET components above 20 eV/nm. The high LET contribution to the total absorbed dose in the Bragg peak is significantly larger with increasing ion charge as a natural result of higher stopping power and lower range straggling. The fact that the range straggling and multiple scattering are reduced by half from hydrogen to helium increases the possibility to accurately deposit only the high LET component in the tumor with negligible dose to organs at risk. Therefore, the lateral penumbra is significantly improved and the higher dose gradients of {sup 7}Li and {sup 12}C ions both longitudinally and laterally will be of major advantage in biological optimized radiation therapy. With increasing charge of the ion, the high LET absorbed dose in the beam entrance and the plateau regions where healthy normal tissues are generally located is also increased. The dose distribution of the high LET components in the {sup 7}Li beam is only located around the Bragg peak, characterized by a Gaussian

  3. The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays.

    PubMed

    Rapp, B; Perichon, N; Denoziere, M; Daures, J; Ostrowsky, A; Bordy, J-M

    2013-05-07

    Water calorimeters are used to establish absorbed dose standards in several national metrology laboratories involved in ionizing radiation dosimetry. These calorimeters have been first used in high-energy photons of (60)Co or accelerator beams, where the depth of measurement in water is large (5 or 10 cm). The LNE-LNHB laboratory has developed a specific calorimeter which makes measurements at low depth in water (down to 0.5 cm) easier, in order to fulfil the reference conditions required by the international dosimetry protocols for medium-energy x-rays. This new calorimeter was first used to measure the absorbed dose rate in water at a depth of 2 cm for six medium-energy x-ray reference beams with a tube potential from 80 to 300 kV. The relative combined standard uncertainty obtained on the absorbed dose rate to water is lower than 0.8%. An overview of the design of the calorimeter is given, followed by a detailed description of the calculation of the correction factors and the calorimetric measurements.

  4. Efficacy of a Radiation Absorbing Shield in Reducing Dose to the Interventionalist During Peripheral Endovascular Procedures: A Single Centre Pilot Study

    SciTech Connect

    Power, S.; Mirza, M.; Thakorlal, A.; Ganai, B.; Gavagan, L. D.; Given, M. F.; Lee, M. J.

    2015-06-15

    PurposeThis prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures.Materials and MethodsA commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated.ResultsTLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142).ConclusionInitial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator’s body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.

  5. Numerical wave tank based on a conserved wave-absorbing method

    NASA Astrophysics Data System (ADS)

    Hu, Zhe; Tang, Wen-yong; Xue, Hong-xiang; Zhang, Xiao-ying

    2016-03-01

    Recently the numerical wave tank has become a widely-used tool to study waves as well as wave-structure interactions, and the wave-absorbing method is very important as its effect on the quality of waves generated. The relaxation method and the derived momentum source method are often utilized, however, the damping weight is constant during calculation and repeated trials are required to obtain an acceptable wave-absorbing effect. To address the abovementioned issues, a conserved wave-absorbing method is developed. The damping weight is determined by solving the mass conservation equation of the absorbing region at every time step. Based on this method, a two-dimensional numerical wave tank is established by using the VB language to simulate various waves by which the validation of this method is evaluated.

  6. Terahertz dual-band metamaterial absorber based on graphene/MgF(2) multilayer structures.

    PubMed

    Su, Zhaoxian; Yin, Jianbo; Zhao, Xiaopeng

    2015-01-26

    We design an ultra-thin terahertz metamaterial absorber based on graphene/MgF(2) multilayer stacking unit cells arrayed on an Au film plane and theoretically demonstrate a dual-band total absorption effect. Due to strong anisotropic permittivity, the graphene/MgF(2) multilayer unit cells possess a hyperbolic dispersion. The strong electric and magnetic dipole resonances between unit cells make the impedance of the absorber match to that of the free space, which induces two total absorption peaks in terahertz range. These absorption peaks are insensitive to the polarization and nearly omnidirectional for the incident angle. But the absorption intensity and frequency depend on material and geometric parameters of the multilayer structure. The absorbed electromagnetic waves are finally converted into heat and, as a result, the absorber shows a good nanosecond photothermal effect.

  7. Dual band metamaterial perfect absorber based on artificial dielectric “molecules”

    PubMed Central

    Liu, Xiaoming; Lan, Chuwen; Li, Bo; Zhao, Qian; Zhou, Ji

    2016-01-01

    Dual band metamaterial perfect absorbers with two absorption bands are highly desirable because of their potential application areas such as detectors, transceiver system, and spectroscopic imagers. However, most of these dual band metamaterial absorbers proposed were based on resonances of metal patterns. Here, we numerically and experimentally demonstrate a dual band metamaterial perfect absorber composed of artificial dielectric “molecules” with high symmetry. The artificial dielectric “molecule” consists of four “atoms” of two different sizes corresponding to two absorption bands with near unity absorptivity. Numerical and experimental absorptivity verify that the dual-band metamaterial absorber is polarization insensitive and can operate in wide-angle incidence. PMID:27406699

  8. Ultra-thin wideband magnetic-type metamaterial absorber based on LC resonator at low frequencies

    NASA Astrophysics Data System (ADS)

    Zhang, Linbo; Zhou, Peiheng; Chen, Haiyan; Lu, Haipeng; Xie, Jianliang; Deng, Longjiang

    2015-10-01

    In this paper, we propose to realize a broad absorption band in the frequency regimes of 2-6 GHz based on multiple resonances. A magnetic-type metamaterial absorber with cross-arrow pattern is further demonstrated numerically and experimentally. Two absorption resonances are generated by LC resonance, leading to bandwidth expansion. The equivalent circuit theory and the surface current distributions of the proposed absorber are discussed to analyze the physical mechanism. Moreover, the broad bandwidth can be maintained as incident angle up to 30° for transverse electric polarization and 45° for transverse magnetic polarization. Finally, experimental results show that the proposed absorber with the total thickness of 2.4 mm exhibits a -10 dB absorption bandwidth by more than 70 %. The low-frequency absorber has potential applications in the area of eliminating microwave energy.

  9. Fluence-to-absorbed-dose conversion coefficients for neutron beams from 0.001 eV to 100 GeV calculated for a set of pregnant female and fetus models

    NASA Astrophysics Data System (ADS)

    Taranenko, Valery; Xu, X. George

    2008-03-01

    Protection of fetuses against external neutron exposure is an important task. This paper reports a set of absorbed dose conversion coefficients for fetal and maternal organs for external neutron beams using the RPI-P pregnant female models and the MCNPX code. The newly developed pregnant female models represent an adult female with a fetus including its brain and skeleton at the end of each trimester. The organ masses were adjusted to match the reference values within 1%. For the 3 mm cubic voxel size, the models consist of 10-15 million voxels for 35 organs. External monoenergetic neutron beams of six standard configurations (AP, PA, LLAT, RLAT, ROT and ISO) and source energies 0.001 eV-100 GeV were considered. The results are compared with previous data that are based on simplified anatomical models. The differences in dose depend on source geometry, energy and gestation periods: from 20% up to 140% for the whole fetus, and up to 100% for the fetal brain. Anatomical differences are primarily responsible for the discrepancies in the organ doses. For the first time, the dependence of mother organ doses upon anatomical changes during pregnancy was studied. A maximum of 220% increase in dose was observed for the placenta in the nine months model compared to three months, whereas dose to the pancreas, small and large intestines decreases by 60% for the AP source for the same models. Tabulated dose conversion coefficients for the fetus and 27 maternal organs are provided.

  10. Evaluation of absorbed and effective doses to patients from radiopharmaceuticals using the ICRP 110 reference computational phantoms and ICRP 103 formulation.

    PubMed

    Hadid, Lama; Gardumi, Anna; Desbrée, Aurélie

    2013-09-01

    In diagnostic nuclear medicine, mean absorbed doses to patients' organs and effective doses are published for standard stylised anatomic models. To provide more realistic and detailed geometries of the human morphology, the International Commission on Radiological Protection (ICRP) has recently adopted male and female voxel phantoms to represent the reference adult. This work investigates the impact of the use of these new computational phantoms. The absorbed doses were calculated for 11 different radiopharmaceuticals currently used in diagnostic nuclear medicine. They were calculated for the ICRP 110 reference computational phantoms using the OEDIPE software and the MCNP extended Monte Carlo code. The biokinetic models were issued from ICRP Publications 53, 80 and 106. The results were then compared with published values given in these ICRP Publications. To discriminate the effect of anatomical differences on organ doses from the effect of the calculation method, the Monte Carlo calculations were repeated for the reference adult stylised phantom. The voxel effect, the influence of the use of different densities and nuclear decay data were also investigated. Effective doses were determined for the ICRP 110 adult reference computational phantom with the tissue weighting factor of ICRP Publication 60 and the tissue weighting factors of ICRP Publication 103. The calculation method and, in particular, the simulation of the electron transport have a significant influence on the calculated doses, especially, for small and walled organs. Overestimates of >200 % were observed for the urinary bladder wall of the stylised phantom compared with the computational phantoms. The unrealistic organ topology of the stylised phantom leads to important dose differences, sometimes by an order of magnitude. The effective doses calculated using the new computational phantoms and the new tissue weighting factors are globally lower than the published ones, except for some

  11. Microwave absorption properties of double-layer absorber based on carbonyl iron/barium hexaferrite composites

    NASA Astrophysics Data System (ADS)

    Ren, Xiaohu; Fan, Huiqing; Cheng, Yankui

    2016-05-01

    The microwave absorption properties of BaCo0.4Zn1.6Fe16O27 ferrite and carbonyl iron powder with single-layer and double-layer composite absorbers were investigated based on the electromagnetic transmission line theory in the frequency range from 1 to 14 GHz. XRD was used to characterize the structure of prepared absorbing particles. SEM was used to examine the micromorphology of the particles and composites. The complex permittivity and permeability of composites were measured by using a vector network analyzer. The reflection loss of the single-layer and double-layer absorbers with different thicknesses and orders was investigated. The results show that double-layer absorbers have better microwave absorption properties than single-layer absorbers. The microwave absorption properties of the double-layer structure are influenced by the coupling interactions between the matching and absorption layers. As the pure ferrite used as matching layer and the composite of BF-5CI used as absorption, the minimum RL of absorber can achieve to -55.4 dB and the bandwidth of RL <-10 dB ranged from 5.6 to 10.8 GHz when the thicknesses of matching layer and absorption layer were 0.9 and 1.4 mm, respectively.

  12. Thermal tuning of infrared resonant absorbers based on hybrid gold-VO{sub 2} nanostructures

    SciTech Connect

    Kocer, Hasan; Butun, Serkan; Aydin, Koray; Banar, Berker; Wang, Kevin; Wu, Junqiao; Tongay, Sefaatttin

    2015-04-20

    Resonant absorbers based on plasmonic materials, metamaterials, and thin films enable spectrally selective absorption filters, where absorption is maximized at the resonance wavelength. By controlling the geometrical parameters of nano/microstructures and materials' refractive indices, resonant absorbers are designed to operate at wide range of wavelengths for applications including absorption filters, thermal emitters, thermophotovoltaic devices, and sensors. However, once resonant absorbers are fabricated, it is rather challenging to control and tune the spectral absorption response. Here, we propose and demonstrate thermally tunable infrared resonant absorbers using hybrid gold-vanadium dioxide (VO{sub 2}) nanostructure arrays. Absorption intensity is tuned from 90% to 20% and 96% to 32% using hybrid gold-VO{sub 2} nanowire and nanodisc arrays, respectively, by heating up the absorbers above the phase transition temperature of VO{sub 2} (68 °C). Phase change materials such as VO{sub 2} deliver useful means of altering optical properties as a function of temperature. Absorbers with tunable spectral response can find applications in sensor and detector applications, in which external stimulus such as heat, electrical signal, or light results in a change in the absorption spectrum and intensity.

  13. Absorbable magnesium-based stent: physiological factors to consider for in vitro degradation assessments

    PubMed Central

    Wang, Juan; Smith, Christopher E.; Sankar, Jagannathan; Yun, Yeoheung; Huang, Nan

    2015-01-01

    Absorbable metals have been widely tested in various in vitro settings using cells to evaluate their possible suitability as an implant material. However, there exists a gap between in vivo and in vitro test results for absorbable materials. A lot of traditional in vitro assessments for permanent materials are no longer applicable to absorbable metallic implants. A key step is to identify and test the relevant microenvironment and parameters in test systems, which should be adapted according to the specific application. New test methods are necessary to reduce the difference between in vivo and in vitro test results and provide more accurate information to better understand absorbable metallic implants. In this investigative review, we strive to summarize the latest test methods for characterizing absorbable magnesium-based stent for bioabsorption/biodegradation behavior in the mimicking vascular environments. Also, this article comprehensively discusses the direction of test standardization for absorbable stents to paint a more accurate picture of the in vivo condition around implants to determine the most important parameters and their dynamic interactions. PMID:26816631

  14. Thermal tuning of infrared resonant absorbers based on hybrid gold-VO2 nanostructures

    NASA Astrophysics Data System (ADS)

    Kocer, Hasan; Butun, Serkan; Banar, Berker; Wang, Kevin; Tongay, Sefaatttin; Wu, Junqiao; Aydin, Koray

    2015-04-01

    Resonant absorbers based on plasmonic materials, metamaterials, and thin films enable spectrally selective absorption filters, where absorption is maximized at the resonance wavelength. By controlling the geometrical parameters of nano/microstructures and materials' refractive indices, resonant absorbers are designed to operate at wide range of wavelengths for applications including absorption filters, thermal emitters, thermophotovoltaic devices, and sensors. However, once resonant absorbers are fabricated, it is rather challenging to control and tune the spectral absorption response. Here, we propose and demonstrate thermally tunable infrared resonant absorbers using hybrid gold-vanadium dioxide (VO2) nanostructure arrays. Absorption intensity is tuned from 90% to 20% and 96% to 32% using hybrid gold-VO2 nanowire and nanodisc arrays, respectively, by heating up the absorbers above the phase transition temperature of VO2 (68 °C). Phase change materials such as VO2 deliver useful means of altering optical properties as a function of temperature. Absorbers with tunable spectral response can find applications in sensor and detector applications, in which external stimulus such as heat, electrical signal, or light results in a change in the absorption spectrum and intensity.

  15. Graphene-based extremely wide-angle tunable metamaterial absorber.

    PubMed

    Linder, Jacob; Halterman, Klaus

    2016-08-24

    We investigate the absorption properties of graphene-based anisotropic metamaterial structures where the metamaterial layer possesses an electromagnetic response corresponding to a near-zero permittivity. We find that through analytical and numerical studies, near perfect absorption arises over an unusually broad range of beam incidence angles. Due to the presence of graphene, the absorption is tunable via a gate voltage, providing dynamic control of the energy transmission. We show that this strongly enhanced absorption arises due to a coupling between light and a fast wave-mode propagating along the graphene/metamaterial hybrid.

  16. Graphene-based extremely wide-angle tunable metamaterial absorber

    PubMed Central

    Linder, Jacob; Halterman, Klaus

    2016-01-01

    We investigate the absorption properties of graphene-based anisotropic metamaterial structures where the metamaterial layer possesses an electromagnetic response corresponding to a near-zero permittivity. We find that through analytical and numerical studies, near perfect absorption arises over an unusually broad range of beam incidence angles. Due to the presence of graphene, the absorption is tunable via a gate voltage, providing dynamic control of the energy transmission. We show that this strongly enhanced absorption arises due to a coupling between light and a fast wave-mode propagating along the graphene/metamaterial hybrid. PMID:27554137

  17. Absorbance Based Light Emitting Diode Optical Sensors and Sensing Devices

    PubMed Central

    O'Toole, Martina; Diamond, Dermot

    2008-01-01

    The ever increasing demand for in situ monitoring of health, environment and security has created a need for reliable, miniaturised sensing devices. To achieve this, appropriate analytical devices are required that possess operating characteristics of reliability, low power consumption, low cost, autonomous operation capability and compatibility with wireless communications systems. The use of light emitting diodes (LEDs) as light sources is one strategy, which has been successfully applied in chemical sensing. This paper summarises the development and advancement of LED based chemical sensors and sensing devices in terms of their configuration and application, with the focus on transmittance and reflectance absorptiometric measurements. PMID:27879829

  18. Verification of absorbed dose determined with plane-parallel chambers in clinical electron beams following AAPM Task Group 39 protocol using ferrous sulphate dosimetry.

    PubMed

    Xu, Z; Li, H; Almond, P R; Guan, T Y

    1996-03-01

    The absorbed dose values determined with the Exradin and PTW-Markus plane-parallel chambers were compared to the values obtained with the ferrous sulphate dosimetry for a number of the Philips SL25 and the Therac 20 electron beams. For the plane-parallel chambers, the cavity-gas calibration factor Ngaspp, was derived by a direct comparison with a calibrated cylindrical chamber using the three different calibration methods as proposed by the newly published AAPM TG 39 protocol. For the ferrous sulphate dosimetry, an epsilon mG value of 352 x 10(-6) m-2 kg-1 Gy-1 was adopted from ICRU Report No. 35. The average ratio of the dose values determined with the plane-parallel chambers and the dose values determined with the Fricke dosimetry system was 1.001 +/- 1.4%. These measurements are consistent with the AAPM TG 39 protocol.

  19. Dose rate effects in radiation degradation of polymer-based cable materials

    NASA Astrophysics Data System (ADS)

    Plaček, V.; Bartoníček, B.; Hnát, V.; Otáhal, B.

    2003-08-01

    Cable ageing under the nuclear power plant (NPP) conditions must be effectively managed to ensure that the required plant safety and reliability are maintained throughout the plant service life. Ionizing radiation is one of the main stressors causing age-related degradation of polymer-based cable materials in air. For a given absorbed dose, radiation-induced damage to a polymer in air environment usually depends on the dose rate of the exposure. In this work, the effect of dose rate on the degradation rate has been studied. Three types of NPP cables (with jacket/insulation combinations PVC/PVC, PVC/PE, XPE/XPE) were irradiated at room temperature using 60Co gamma ray source at average dose rates of 7, 30 and 100 Gy/h with the doses up to 590 kGy. The irradiated samples have been tested for their mechanical properties, thermo-oxidative stability (using differential scanning calorimetry, DSC), and density. In the case of PVC and PE samples, the tested properties have shown evident dose rate effects, while the XPE material has shown no noticeable ones. The values of elongation at break and the thermo-oxidative stability decrease with the advanced degradation, density tends to increase with the absorbed dose. For XPE samples this effect can be partially explained by the increase of crystallinity. It was tested by the DSC determination of the crystalline phase amount.

  20. Determinants of visual pigment absorbance: identification of the retinylidene Schiff's base counterion in bovine rhodopsin.

    PubMed

    Nathans, J

    1990-10-16

    The role of negatively charged residues in tuning the absorbance spectrum of bovine rhodopsin has been tested by mutating each aspartate and glutamate to asparagine and glutamine, respectively. Previous work demonstrated that aspartate83, glutamate122, and glutamate134 can be replaced by neutral residues with little or no effect on the absorbance spectrum of the resulting pigment [Nathans, J. (1990) Biochemistry 29, 937-942]. With one exception, mutations at the remaining 19 aspartate and glutamate residues result in very nearly wild-type absorbance spectra. The exception is glutamate113: mutation to glutamine causes the pigment to absorb at 380 nm, reflecting deprotonation of the retinylidene Schiff's base. Upon addition of either chloride, bromide, or iodide, the absorbance rapidly shifts to 495, 498, or 504.5 nm, respectively, reflecting protonation of the Schiff's base. The progressive red shift observed upon addition of halides with larger atomic radii strongly suggests that halides are serving as the Schiff's base counterion. Halides have no effect on the absorbance spectrum of wild-type rhodopsin. I infer, therefore, that glutamate113 is the retinylidene Schiff's base counterion in wild-type rhodopsin. Sakmar et al. [(1989) Proc. Natl. Acad. Sci. U.S.A. 86, 8309-8313] and Zhukovsky and Oprian [(1989) Science 246, 928-930] have arrived at the same conclusion based upon a related series of experiments. These data support a model in which spectral tuning in bovine rhodopsin results from interactions between the polyene chain of 11-cis-retinal and uncharged amino acids in the binding pocket.

  1. Simulation of computed tomography dose based on voxel phantom

    NASA Astrophysics Data System (ADS)

    Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun

    2017-01-01

    Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.

  2. Alpha particles at energies of 10 MeV to 1 TeV: conversion coefficients for fluence-to-absorbed dose, effective dose, and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.A.

    PubMed

    Copeland, Kyle; Parker, Donald E; Friedberg, Wallace

    2010-03-01

    Conversion coefficients have been calculated for fluence to absorbed dose, fluence to effective dose and fluence to gray equivalent, for isotropic exposure to alpha particles in the energy range of 10 MeV to 1 TeV (0.01-1000 GeV). The coefficients were calculated using Monte Carlo transport code MCNPX 2.7.A and BodyBuilder 1.3 anthropomorphic phantoms modified to allow calculation of effective dose to a Reference Person using tissues and tissue weighting factors from 1990 and 2007 recommendations of the International Commission on Radiological Protection (ICRP) and gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. Coefficients for effective dose are within 30 % of those calculated using ICRP 1990 recommendations.

  3. Fluence to absorbed dose, effective dose and gray equivalent conversion coefficients for iron nuclei from 10 MeV to 1 TeV, calculated using Monte Carlo radiation transport code MCNPX 2.7.A.

    PubMed

    Copeland, Kyle; Parker, Donald E; Friedberg, Wallace

    2010-03-01

    Conversion coefficients have been calculated for fluence-to-absorbed dose, fluence-to-effective dose and fluence-to-gray equivalent for isotropic exposure of an adult male and an adult female to (56)Fe(26+) in the energy range of 10 MeV to 1 TeV (0.01-1000 GeV). The coefficients were calculated using Monte Carlo transport code MCNPX 2.7.A and BodyBuilder 1.3 anthropomorphic phantoms modified to allow calculation of effective dose using tissues and tissue weighting factors from either the 1990 or 2007 recommendations of the International Commission on Radiological Protection (ICRP) and gray equivalent to selected tissues as recommended by the National Council on Radiation Protection and Measurements. Calculations using ICRP 2007 recommendations result in fluence-to-effective dose conversion coefficients that are almost identical at most energies to those calculated using ICRP 1990 recommendations.

  4. Dose banding as an alternative to body surface area-based dosing of chemotherapeutic agents

    PubMed Central

    Chatelut, E; White-Koning, M L; Mathijssen, R HJ; Puisset, F; Baker, S D; Sparreboom, A

    2012-01-01

    Background: Dose banding is a recently suggested dosing method that uses predefined ranges (bands) of body surface area (BSA) to calculate each patient's dose by using a single BSA-value per band. Thus, drugs with sufficient long-term stability can be prepared in advance. The main advantages of dose banding are to reduce patient waiting time and improve pharmacy capacity planning; additional benefits include reduced medication errors, reduced drug wastage, and prospective quality control. This study compares dose banding with individual BSA dosing and fixed dose according to pharmacokinetic criteria. Methods: Three BSA bands were defined: BSA<1.7 m2, 1.7 m2⩽BSA<1.9 m2, BSA⩾1.9 m2 and each patient dose was calculated based on a unique BSA-value per band (1.55, 1.80, and 2.05 m2, respectively). By using individual clearance values of six drugs (cisplatin, docetaxel, paclitaxel, doxorubicin, irinotecan, and topotecan) from 1012 adult cancer patients in total, the AUCs corresponding to three dosing methods (BSA dosing, dose banding, and fixed dose) were compared with a target AUC for each drug. Results: For all six drugs, the per cent variation in individual dose obtained with dose banding compared with BSA dosing ranged between −14% and +22%, and distribution of AUC values was very similar with both dosing methods. In terms of reaching the target AUC, there was no significant difference in precision between dose banding and BSA dosing, except for paclitaxel (32.0% vs 30.7%, respectively; P<0.05). However, precision was significantly better for BSA dosing compared with fixed dose for four out of six drugs. Conclusion: For the studied drugs, implementation of dose banding should be considered as it entails no significant increase in interindividual plasma exposure. PMID:22929884

  5. Evaluation of factors to convert absorbed dose calibrations from graphite to water for the NPL high-energy photon calibration service.

    PubMed

    Nutbrown, R F; Duane, S; Shipley, D R; Thomas, R A S

    2002-02-07

    The National Physical Laboratory (NPL) provides a high-energy photon calibration service using 4-19 MV x-rays and 60Co gamma-radiation for secondary standard dosemeters in terms of absorbed dose to water. The primary standard used for this service is a graphite calorimeter and so absorbed dose calibrations must be converted from graphite to water. The conversion factors currently in use were determined prior to the launch of this service in 1988. Since then, it has been found that the differences in inherent filtration between the NPL LINAC and typical clinical machines are large enough to affect absorbed dose calibrations and, since 1992, calibrations have been performed in heavily filtered qualities. The conversion factors for heavily filtered qualities were determined by interpolation and extrapolation of lightly filtered results as a function of tissue phantom ratio 20,10 (TPR20,10). This paper aims to evaluate these factors for all mega-voltage photon energies provided by the NPL LINAC for both lightly and heavily filtered qualities and for 60Co y-radiation in two ways. The first method involves the use of the photon fluence-scaling theorem. This states that if two blocks of different material are irradiated by the same photon beam, and if all dimensions are scaled in the inverse ratio of the electron densities of the two media, then, assuming that all photon interactions occur by Compton scatter the photon attenuation and scatter factors at corresponding scaled points of measurement in the phantom will be identical. The second method involves making in-phantom measurements of chamber response at a constant target-chamber distance. Monte Carlo techniques are then used to determine the corresponding dose to the medium in order to determine the chamber calibration factor directly. Values of the ratio of absorbed dose calibration factors in water and in graphite determined in these two ways agree with each other to within 0.2% (1sigma uncertainty). The best fit

  6. SU-F-18C-08: A Validation Study of a Commercially Available Software Package's Absorbed Dose Estimates in a Physical Phantom

    SciTech Connect

    Supanich, M; Siegelman, J

    2014-06-15

    Purpose: This study assesses the accuracy of the absorbed dose estimates from CT scans generated by Monte Carlo (MC) simulation using a commercially available radiation dose monitoring software program. Methods: Axial CT studies of an anthropomorphic abdomen phantom with dose bores at a central location and 4 peripheral locations were conducted using a fixed tube current at 120 kV. A 100 mm ion chamber and a 0.6 cc ion chamber calibrated at diagnostic energy levels were used to measure dose in the phantom at each of the 5 dose bore locations. Simulations using the software program's Monte Carlo engine were run using a mathematical model of the anthropomorphic phantom to determine conversion coefficients between the CTDIvol used for the study and the dose at the location of the dose bores. Simulations were conducted using both the software's generic CT beam model and a refined model generated using HVL and bow tie filter profile measurements made on the scanner used for the study. Results: Monte Carlo simulations completed using the generalized beam model differed from the measured conversion factors by an absolute value average of 13.0% and 13.8% for the 100 mm and 0.6 cc ion chamber studies, respectively. The MC simulations using the scanner specific beam model generated conversion coefficients that differed from the CTDIvol to measured dose conversion coefficients by an absolute value average of 7.3% and 7.8% for the 100 mm and 0.6 cc ion chamber cases, respectively. Conclusion: A scanner specific beam model used in MC simulations generates more accurate dose conversion coefficients in an anthropomorphic phantom than those generated with a generalized beam model. Agreement between measured conversion coefficients and simulated values were less than 20% for all positions using the universal beam model.

  7. Use of Monte Carlo simulations with a realistic rat phantom for examining the correlation between hematopoietic system response and red marrow absorbed dose in Brown Norway rats undergoing radionuclide therapy with {sup 177}Lu- and {sup 90}Y-BR96 mAbs

    SciTech Connect

    Larsson, Erik; Ljungberg, Michael; Martensson, Linda; Nilsson, Rune; Tennvall, Jan; Strand, Sven-Erik; Joensson, Bo-Anders

    2012-07-15

    Purpose: Biokinetic and dosimetry studies in laboratory animals often precede clinical radionuclide therapies in humans. A reliable evaluation of therapeutic efficacy is essential and should be based on accurate dosimetry data from a realistic dosimetry model. The aim of this study was to develop an anatomically realistic dosimetry model for Brown Norway rats to calculate S factors for use in evaluating correlations between absorbed dose and biological effects in a preclinical therapy study. Methods: A realistic rat phantom (Roby) was used, which has some flexibility that allows for a redefinition of organ sizes. The phantom was modified to represent the anatomic geometry of a Brown Norway rat, which was used for Monte Carlo calculations of S factors. Kinetic data for radiolabeled BR96 monoclonal antibodies were used to calculate the absorbed dose. Biological data were gathered from an activity escalation study with {sup 90}Y- and {sup 177}Lu-labeled BR96 monoclonal antibodies, in which blood cell counts and bodyweight were examined up to 2 months follow-up after injection. Reductions in white blood cell and platelet counts and declines in bodyweight were quantified by four methods and compared to the calculated absorbed dose to the bone marrow or the total body. Results: A red marrow absorbed dose-dependent effect on hematological parameters was observed, which could be evaluated by a decrease in blood cell counts. The absorbed dose to the bone marrow, corresponding to the maximal tolerable activity that could safely be administered, was determined to 8.3 Gy for {sup 177}Lu and 12.5 Gy for {sup 90}Y. Conclusions: There was a clear correlation between the hematological effects, quantified with some of the studied parameters, and the calculated red marrow absorbed doses. The decline in body weight was stronger correlated to the total body absorbed dose, rather than the red marrow absorbed dose. Finally, when considering a constant activity concentration, the phantom

  8. A Minute Dose of 14C-b-Carotene is Absorbed and Converted to Retinoids in Humans

    Technology Transfer Automated Retrieval System (TEKTRAN)

    We dosed 8 adults with 14C-all-trans [10,10',11,11'-14C]-B-carotene (1.01 nmol) to quantify its absorption and metabolism. We used accelerator mass spectrometry (AMS) to measure 14C eliminated in feces over 14 days, in urine over 30 days, and that was retained in plasma over 166 days since dose. We...

  9. Nanosecond passively Q-switched Nd:YVO4 laser based on WS2 saturable absorber

    NASA Astrophysics Data System (ADS)

    Wang, Xi; Li, Lu; Wang, Yonggang; Zhang, Ling; Wen, Qiao; Yang, Guowen

    2017-04-01

    We report on a nanosecond pulse generation in a diode end-pumped passively Q-switched Nd:YVO4 laser using a tungsten disulfide (WS2) solution saturable absorber (SA). The WS2 suspension is fabricated by the liquid-phase-exfoliated method and injected into a quartz cell for the use of SA. Compared with solid absorber, such solution absorber has the virtues of good optical transparency, high heat dissipation and long term stability. By inserting the WS2 solution SA in the laser cavity, a stable Q-switched laser operation centered at 1064.45 nm wavelength is obtained with the shortest pulse duration of 788 ns and corresponding repetition rate of 333.5 kHz. The maximum average output power is registered to be 720 mW with the slope efficiency of 7.8%. To the best of our knowledge, it is the highest output power so far among pulsed lasers based on transition metal dichalcogenides (TMDs) SAs. The results demonstrate that WS2 solution absorber is a promising saturable absorber for the generation of high output power pulsed lasers.

  10. Sound-absorbing slabs and structures based on granular materials (bound and unbound). [energy absorbing efficiency of porous material

    NASA Technical Reports Server (NTRS)

    Petre-Lazar, S.; Popeea, G.

    1974-01-01

    Sound absorbing slabs and structures made up of bound or unbound granular materials are considered and how to manufacture these elements at the building site. The raw material is a single grain powder (sand, expanded blast furnace slag, etc.) that imparts to the end products an apparent porosity of 25-45% and an energy dissipation within the structure leading to absorption coefficients that can be compared with those of mineral wool and urethane.

  11. Role of shielding in modulating the effects of solar particle events: Monte Carlo calculation of absorbed dose and DNA complex lesions in different organs

    NASA Technical Reports Server (NTRS)

    Ballarini, F.; Biaggi, M.; De Biaggi, L.; Ferrari, A.; Ottolenghi, A.; Panzarasa, A.; Paretzke, H. G.; Pelliccioni, M.; Sala, P.; Scannicchio, D.; Zankl, M.; Townsend, L. W. (Principal Investigator)

    2004-01-01

    Distributions of absorbed dose and DNA clustered damage yields in various organs and tissues following the October 1989 solar particle event (SPE) were calculated by coupling the FLUKA Monte Carlo transport code with two anthropomorphic phantoms (a mathematical model and a voxel model), with the main aim of quantifying the role of the shielding features in modulating organ doses. The phantoms, which were assumed to be in deep space, were inserted into a shielding box of variable thickness and material and were irradiated with the proton spectra of the October 1989 event. Average numbers of DNA lesions per cell in different organs were calculated by adopting a technique already tested in previous works, consisting of integrating into "condensed-history" Monte Carlo transport codes--such as FLUKA--yields of radiobiological damage, either calculated with "event-by-event" track structure simulations, or taken from experimental works available in the literature. More specifically, the yields of "Complex Lesions" (or "CL", defined and calculated as a clustered DNA damage in a previous work) per unit dose and DNA mass (CL Gy-1 Da-1) due to the various beam components, including those derived from nuclear interactions with the shielding and the human body, were integrated in FLUKA. This provided spatial distributions of CL/cell yields in different organs, as well as distributions of absorbed doses. The contributions of primary protons and secondary hadrons were calculated separately, and the simulations were repeated for values of Al shielding thickness ranging between 1 and 20 g/cm2. Slight differences were found between the two phantom types. Skin and eye lenses were found to receive larger doses with respect to internal organs; however, shielding was more effective for skin and lenses. Secondary particles arising from nuclear interactions were found to have a minor role, although their relative contribution was found to be larger for the Complex Lesions than for the

  12. High-performance terahertz wave absorbers made of silicon-based metamaterials

    SciTech Connect

    Yin, Sheng; Zhu, Jianfei; Jiang, Wei; Yuan, Jun; Yin, Ge; Ma, Yungui; Xu, Wendao; Xie, Lijuan; Ying, Yibin

    2015-08-17

    Electromagnetic (EM) wave absorbers with high efficiency in different frequency bands have been extensively investigated for various applications. In this paper, we propose an ultra-broadband and polarization-insensitive terahertz metamaterial absorber based on a patterned lossy silicon substrate. Experimentally, a large absorption efficiency more than 95% in a frequency range of 0.9–2.5 THz was obtained up to a wave incident angle as large as 70°. Much broader absorption bandwidth and excellent oblique incidence absorption performance are numerically demonstrated. The underlying mechanisms due to the combination of a waveguide cavity mode and impedance-matched diffraction are analyzed in terms of the field patterns and the scattering features. The monolithic THz absorber proposed here may find important applications in EM energy harvesting systems such as THz barometer or biosensor.

  13. A polarization insensitive and broadband metamaterial absorber based on three-dimensional structure

    NASA Astrophysics Data System (ADS)

    Tang, Jingyao; Xiao, Zhongyin; Xu, Kaikai; Liu, Dejun

    2016-08-01

    In this paper, we propose a three-dimensional metamaterial absorber based on tailored resistive film patch array. The numerical results show that a broadband abs orption more than 90% can be achieved from 58.6 to 91.4 GHz for either transverse electric or magnetic polarization wave at normal incidence. And the E-field, surface current and power loss density distributions in the absorber are investigated to explain the physical mechanism of high absorption. In addition, the absorption efficiency of oblique incidence is also elucidated. According to the analysis of the E-field and power loss density distributions, we explain the absorption differences between TE and TM mode at oblique incidence. The proposed metamaterial absorber will pave the way for practical applications, such as sensing, imaging and stealth technology. Importantly, the design idea has the ability to be extended to terahertz, infrared and optical region.

  14. STARCH-SOYBEAN OIL BASED ULTRAVIOLET ABSORBING COMPOSITES. PREPARATION, CHEMISTY AND POTENTIAL USES

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Excess steam jet-cooking aqueous slurries of starch and vegetable oils or other hydrophobic materials can produce stable aqueous starch-oil composites from renewable resources. Herein, ferulate-based ultraviolet absorbing lipids were synthesized by the lipase catalyzed transesterification of soybea...

  15. Decoloration and mineralization of reactive dyes using electron beam irradiation, Part I: Effect of the dye structure, concentration and absorbed dose (single, binary and ternary systems)

    NASA Astrophysics Data System (ADS)

    Vahdat, Ali; Bahrami, S. Hajir; Arami, M.; Bahjat, A.; Tabakh, F.; Khairkhah, M.

    2012-07-01

    In this study, three different reactive dyes (C.I. Reactive Red 4, C.I. Reactive Blue 2 and C.I. Reactive Yellow 4) and their blend solutions were irradiated with 10 MeV electron beam. Effect of absorbed dose, dye structure and primary solution concentrations on the pH value changes, degree of decoloration and chemical oxygen demand (COD) removal of solutions were investigated. Results show that this method is effective in decomposition and decoloration of the dyes solutions. This method can be applied in mineralization of wastewater containing different dyes.

  16. Update on the Code Intercomparison and Benchmark for Muon Fluence and Absorbed Dose Induced by an 18 GeV Electron Beam After Massive Iron Shielding

    SciTech Connect

    Fasso, A.; Ferrari, A.; Ferrari, A.; Mokhov, N. V.; Mueller, S. E.; Nelson, W. R.; Roesler, S.; Sanami, t.; Striganov, S. I.; Versaci, R.

    2016-12-01

    In 1974, Nelson, Kase and Svensson published an experimental investigation on muon shielding around SLAC high-energy electron accelerators [1]. They measured muon fluence and absorbed dose induced by 14 and 18 GeV electron beams hitting a copper/water beamdump and attenuated in a thick steel shielding. In their paper, they compared the results with the theoretical models available at that time. In order to compare their experimental results with present model calculations, we use the modern transport Monte Carlo codes MARS15, FLUKA2011 and GEANT4 to model the experimental setup and run simulations. The results are then compared between the codes, and with the SLAC data.

  17. Role of cardiac ultrafast cameras with CZT solid-state detectors and software developments on radiation absorbed dose reduction to the patients.

    PubMed

    Gunalp, Bengul

    2015-07-01

    Myocardial perfusion imaging (MPI) is one the most contributing nuclear medicine technique to the annual population dose. The purpose of this study is to compare radiation-absorbed doses to the patients examined by conventional cardiac SPECT (CSPECT) camera and ultrafast cardiac (UFC) camera with cadmium-zinc-telluride (CZT) solid-state detectors. Total injected activity was reduced by 50 % when both stress and rest images were acquired and by 75 % when only stress images were taken with UFC camera. As a result of this, the mean total effective dose was found significantly lower with UFC camera (2.2 ± 1.2 mSv) than CSPECT (7.7 ± 3.8 mSv) (p < 0.001). Further dose reduction was obtained by reducing equivocal test results and unnecessary additional examinations with UFC camera. Using UFC camera, MPI can be conveniently used for the detection of coronary artery disease (CAD) much less increasing annual population radiation dose as it had been before.

  18. Detailed Distribution Map of Absorbed Dose Rate in Air in Tokatsu Area of Chiba Prefecture, Japan, Constructed by Car-Borne Survey 4 Years after the Fukushima Daiichi Nuclear Power Plant Accident

    PubMed Central

    Inoue, Kazumasa; Arai, Moeko; Fujisawa, Makoto; Saito, Kyouko; Fukushi, Masahiro

    2017-01-01

    A car-borne survey was carried out in the northwestern, or Tokatsu, area of Chiba Prefecture, Japan, to make a detailed distribution map of absorbed dose rate in air four years after the Fukushima Daiichi Nuclear Power Plant accident. This area was chosen because it was the most heavily radionuclide contaminated part of Chiba Prefecture and it neighbors metropolitan Tokyo. Measurements were performed using a 3-in × 3-in NaI(Tl) scintillation spectrometer in June 2015. The survey route covered the whole Tokatsu area which includes six cities. A heterogeneous distribution of absorbed dose rate in air was observed on the dose distribution map. Especially, higher absorbed dose rates in air exceeding 80 nGy h-1 were observed along national roads constructed using high porosity asphalt, whereas lower absorbed dose rates in air were observed along local roads constructed using low porosity asphalt. The difference between these asphalt types resulted in a heterogeneous dose distribution in the Tokatsu area. The mean of the contribution ratio of artificial radionuclides to absorbed dose rate in air measured 4 years after the accident was 29% (9–50%) in the Tokatsu area. The maximum absorbed dose rate in air, 201 nGy h-1 was observed at Kashiwa City. Radiocesium was deposited in the upper 1 cm surface layer of the high porosity asphalt which was collected in Kashiwa City and the environmental half-life of the absorbed dose rate in air was estimated to be 1.7 years. PMID:28129382

  19. Efficacy and immunogenicity of single-dose AdVAV intranasal anthrax vaccine compared to anthrax vaccine absorbed in an aerosolized spore rabbit challenge model.

    PubMed

    Krishnan, Vyjayanthi; Andersen, Bo H; Shoemaker, Christine; Sivko, Gloria S; Tordoff, Kevin P; Stark, Gregory V; Zhang, Jianfeng; Feng, Tsungwei; Duchars, Matthew; Roberts, M Scot

    2015-04-01

    AdVAV is a replication-deficient adenovirus type 5-vectored vaccine expressing the 83-kDa protective antigen (PA83) from Bacillus anthracis that is being developed for the prevention of disease caused by inhalation of aerosolized B. anthracis spores. A noninferiority study comparing the efficacy of AdVAV to the currently licensed Anthrax Vaccine Absorbed (AVA; BioThrax) was performed in New Zealand White rabbits using postchallenge survival as the study endpoint (20% noninferiority margin for survival). Three groups of 32 rabbits were vaccinated with a single intranasal dose of AdVAV (7.5 × 10(7), 1.5 × 10(9), or 3.5 × 10(10) viral particles). Three additional groups of 32 animals received two doses of either intranasal AdVAV (3.5 × 10(10) viral particles) or intramuscular AVA (diluted 1:16 or 1:64) 28 days apart. The placebo group of 16 rabbits received a single intranasal dose of AdVAV formulation buffer. All animals were challenged via the inhalation route with a targeted dose of 200 times the 50% lethal dose (LD50) of aerosolized B. anthracis Ames spores 70 days after the initial vaccination and were followed for 3 weeks. PA83 immunogenicity was evaluated by validated toxin neutralizing antibody and serum anti-PA83 IgG enzyme-linked immunosorbent assays (ELISAs). All animals in the placebo cohort died from the challenge. Three of the four AdVAV dose cohorts tested, including two single-dose cohorts, achieved statistical noninferiority relative to the AVA comparator group, with survival rates between 97% and 100%. Vaccination with AdVAV also produced antibody titers with earlier onset and greater persistence than vaccination with AVA.

  20. Graphene based tunable fractal Hilbert curve array broadband radar absorbing screen for radar cross section reduction

    SciTech Connect

    Huang, Xianjun; Hu, Zhirun; Liu, Peiguo

    2014-11-15

    This paper proposes a new type of graphene based tunable radar absorbing screen. The absorbing screen consists of Hilbert curve metal strip array and chemical vapour deposition (CVD) graphene sheet. The graphene based screen is not only tunable when the chemical potential of the graphene changes, but also has broadband effective absorption. The absorption bandwidth is from 8.9GHz to 18.1GHz, ie., relative bandwidth of more than 68%, at chemical potential of 0eV, which is significantly wider than that if the graphene sheet had not been employed. As the chemical potential varies from 0 to 0.4eV, the central frequency of the screen can be tuned from 13.5GHz to 19.0GHz. In the proposed structure, Hilbert curve metal strip array was designed to provide multiple narrow band resonances, whereas the graphene sheet directly underneath the metal strip array provides tunability and averagely required surface resistance so to significantly extend the screen operation bandwidth by providing broadband impedance matching and absorption. In addition, the thickness of the screen has been optimized to achieve nearly the minimum thickness limitation for a nonmagnetic absorber. The working principle of this absorbing screen is studied in details, and performance under various incident angles is presented. This work extends applications of graphene into tunable microwave radar cross section (RCS) reduction applications.

  1. Characterization of absorbing aerosol types using ground and satellites based observations over an urban environment

    NASA Astrophysics Data System (ADS)

    Bibi, Samina; Alam, Khan; Chishtie, Farrukh; Bibi, Humera

    2017-02-01

    In this paper, for the first time, an effort has been made to seasonally characterize the absorbing aerosols into different types using ground and satellite based observations. For this purpose, optical properties of aerosol retrieved from AErosol RObotic NETwork (AERONET) and Ozone Monitoring Instrument (OMI) were utilized over Karachi for the period 2012 to 2014. Firstly, OMI AODabs was validated with AERONET AODabs and found to have a high degree of correlation. Then, based on this validation, characterization was conducted by analyzing aerosol Fine Mode Fraction (FMF), Angstrom Exponent (AE), Absorption Angstrom Exponent (AAE), Single Scattering Albedo (SSA) and Aerosol Index (AI) and their mutual correlation, to identify the absorbing aerosol types and also to examine the variability in seasonal distribution. The absorbing aerosols were characterized into Mostly Black Carbon (BC), Mostly Dust and Mixed BC & Dust. The results revealed that Mostly BC aerosols contributed dominantly during winter and postmonsoon whereas, Mostly Dust were dominant during summer and premonsoon. These types of absorbing aerosol were also confirmed with MODerate resolution Imaging Spectroradiometer (MODIS) and Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) observations.

  2. Sample Based Unit Liter Dose Estimates

    SciTech Connect

    JENSEN, L.

    2000-04-13

    The Tank Waste Characterization Program has taken many core samples, grab samples, and auger samples from the single-shell and double-shell tanks during the past 10 years. Consequently, the amount of sample data available has increased, both in terms of quantity of sample results and the number of tanks characterized. More and better data is available than when the current radiological and toxicological source terms used in the Basis for Interim Operation (BIO) (FDH 1999a) and the Final Safety Analysis Report (FSAR) (FDH 1999b) were developed. The Nuclear Safety and Licensing (NS and L) organization wants to use the new data to upgrade the radiological and toxicological source terms used in the BIO and FSAR. The NS and L organization requested assistance in producing a statistically based process for developing the source terms. This report describes the statistical techniques used and the assumptions made to support the development of a new radiological source term for liquid and solid wastes stored in single-shell and double-shell tanks. The results given in this report are a revision to similar results given in an earlier version of the document (Jensen and Wilmarth 1999). The main difference between the results in this document and the earlier version is that the dose conversion factors (DCF) for converting {mu}Ci/g or {mu}Ci/L to Sv/L (sieverts per liter) have changed. There are now two DCFs, one based on ICRP-68 and one based on ICW-71 (Brevick 2000).

  3. Comparison of the calculated absorbed dose using the Cadplan™ treatment planning software and Tld-100 measurements in an Alderson-Rando phantom for a bronchogenic treatment

    SciTech Connect

    Gutiérrez Castillo, J. G.; Álvarez Romero, J. T. E-mail: fisarmandotorres@gmail.com Calderón, A. Torres E-mail: fisarmandotorres@gmail.com M, V. Tovar E-mail: fisarmandotorres@gmail.com

    2014-11-07

    To verify the accuracy of the absorbed doses D calculated by a TPS Cadplan for a bronchogenic treatment (in an Alderson-Rando phantom) are chosen ten points with the following D's and localizations. Point 1, posterior position on the left edge with 136.4 Gy. Points: 2, 3 and 4 in the left lung with 104.9, 104.3 and 105.8 Gy, respectively; points 5 and 6 at the mediastinum with 192.4 and 173.5 Gy; points 7, 8 and 9 in the right lung with 105.8, 104.2 and 104.7 Gy, and 10 at posterior position on right edge with 143.7 Gy. IAEA type capsules with TLD 100 powder are placed, planned and irradiated. The evaluation of the absorbed dose is carried out a curve of calibration for the LiF response (nC) {sup vs} {sup DW}, to several cavity theories. The traceability for the DW is obtained with a secondary standard calibrated at the NRC (Canada). The dosimetric properties for the materials considered are determined from the Hounsfield numbers reported by the TPS. The stopping power ratios are calculated for nominal spectrum to 6 MV photons. The percent variations among the planned and determined D in all the cases they are < ± 3%.

  4. Structural changes caused by radiation-induced reduction and radiolysis: the effect of X-ray absorbed dose in a fungal multicopper oxidase.

    PubMed

    De la Mora, Eugenio; Lovett, Janet E; Blanford, Christopher F; Garman, Elspeth F; Valderrama, Brenda; Rudino-Pinera, Enrique

    2012-05-01

    X-ray radiation induces two main effects at metal centres contained in protein crystals: radiation-induced reduction and radiolysis and a resulting decrease in metal occupancy. In blue multicopper oxidases (BMCOs), the geometry of the active centres and the metal-to-ligand distances change depending on the oxidation states of the Cu atoms, suggesting that these alterations are catalytically relevant to the binding, activation and reduction of O(2). In this work, the X-ray-determined three-dimensional structure of laccase from the basidiomycete Coriolopsis gallica (Cg L), a high catalytic potential BMCO, is described. By combining spectroscopic techniques (UV-Vis, EPR and XAS) and X-ray crystallography, structural changes at and around the active copper centres were related to pH and absorbed X-ray dose (energy deposited per unit mass). Depletion of two of the four active Cu atoms as well as low occupancies of the remaining Cu atoms, together with different conformations of the metal centres, were observed at both acidic pH and high absorbed dose, correlating with more reduced states of the active coppers. These observations provide additional evidence to support the role of flexibility of copper sites during O(2) reduction. This study supports previous observations indicating that interpretations regarding redox state and metal coordination need to take radiation effects explicitly into account.

  5. Structural changes caused by radiation-induced reduction and radiolysis: the effect of X-ray absorbed dose in a fungal multicopper oxidase

    PubMed Central

    De la Mora, Eugenio; Lovett, Janet E.; Blanford, Christopher F.; Garman, Elspeth F.; Valderrama, Brenda; Rudino-Pinera, Enrique

    2012-01-01

    X-ray radiation induces two main effects at metal centres contained in protein crystals: radiation-induced reduction and radiolysis and a resulting decrease in metal occupancy. In blue multicopper oxidases (BMCOs), the geometry of the active centres and the metal-to-ligand distances change depending on the oxidation states of the Cu atoms, suggesting that these alterations are catalytically relevant to the binding, activation and reduction of O2. In this work, the X-ray-determined three-dimensional structure of laccase from the basidiomycete Coriolopsis gallica (Cg L), a high catalytic potential BMCO, is described. By combining spectroscopic techniques (UV–Vis, EPR and XAS) and X-ray crystallography, structural changes at and around the active copper centres were related to pH and absorbed X-­ray dose (energy deposited per unit mass). Depletion of two of the four active Cu atoms as well as low occupancies of the remaining Cu atoms, together with different conformations of the metal centres, were observed at both acidic pH and high absorbed dose, correlating with more reduced states of the active coppers. These observations provide additional evidence to support the role of flexibility of copper sites during O2 reduction. This study supports previous observations indicating that interpretations regarding redox state and metal coordination need to take radiation effects explicitly into account. PMID:22525754

  6. Absorbed dose distribution for X-ray beams and beams of electrons from the Therac 10 Neptune linear accelerator.

    PubMed

    Tronc, D; Gayet, P

    1980-02-01

    After a brief presentation of the Therac 10 Neptune linear accelerator a complete set of dose distribution numerical values is given. These values define the depths on the axis as a function of the depth dose and define the penumbra (as characterized by the positions of the isodose curve intersections with parallel planes to the phantom surface) for beams of X-rays and for beams of electrons. Measurements of residual X-rays are given for a 10 MeV beam of electrons.

  7. SU-F-19A-10: Recalculation and Reporting Clinical HDR 192-Ir Head and Neck Dose Distributions Using Model Based Dose Calculation

    SciTech Connect

    Carlsson Tedgren, A; Persson, M; Nilsson, J

    2014-06-15

    Purpose: To retrospectively re-calculate dose distributions for selected head and neck cancer patients, earlier treated with HDR 192Ir brachytherapy, using Monte Carlo (MC) simulations and compare results to distributions from the planning system derived using TG43 formalism. To study differences between dose to medium (as obtained with the MC code) and dose to water in medium as obtained through (1) ratios of stopping powers and (2) ratios of mass energy absorption coefficients between water and medium. Methods: The MC code Algebra was used to calculate dose distributions according to earlier actual treatment plans using anonymized plan data and CT images in DICOM format. Ratios of stopping power and mass energy absorption coefficients for water with various media obtained from 192-Ir spectra were used in toggling between dose to water and dose to media. Results: Differences between initial planned TG43 dose distributions and the doses to media calculated by MC are insignificant in the target volume. Differences are moderate (within 4–5 % at distances of 3–4 cm) but increase with distance and are most notable in bone and at the patient surface. Differences between dose to water and dose to medium are within 1-2% when using mass energy absorption coefficients to toggle between the two quantities but increase to above 10% for bone using stopping power ratios. Conclusion: MC predicts target doses for head and neck cancer patients in close agreement with TG43. MC yields improved dose estimations outside the target where a larger fraction of dose is from scattered photons. It is important with awareness and a clear reporting of absorbed dose values in using model based algorithms. Differences in bone media can exceed 10% depending on how dose to water in medium is defined.

  8. Thin absorber EUV photomask based on mixed Ni and TaN material

    NASA Astrophysics Data System (ADS)

    Hay, Derrick; Bagge, Patrick; Khaw, Ian; Sun, Lei; Wood, Obert; Chen, Yulu; Kim, Ryoung-han; Qi, Zhengqing John; Shi, Zhimin

    2016-05-01

    Lithographic patterning at the 7 and 5 nm nodes will likely require EUV (λ=13.5 nm) lithography for many of the critical levels. All optical elements in an EUV scanner are reflective which requires the EUV photomask to be illuminated at an angle to its normal. Current scanners have an incidence of 6 degree, but future designs will be <6 degrees for high-NA systems. Non-telecentricity has been shown to cause H-V bias due to shadowing, pattern shift through focus, and image contrast lost due to apodization by the reflective mask coating. A thinner EUV absorber can dramatically reduce these issues. Ni offers better EUV absorption than Ta-based materials, which hold promise as a thinner absorber candidate. Unfortunately, the challenge of etching Ni has prevented its adoption into manufacturing. We propose a new absorber material that infuses Ni nanoparticles into the TaN host medium, allowing for the use of established Ta etching chemistry. A thinner is absorber is created due to the enhanced absorption properties of the Ni-Ta nano-composite material. Finite integral method and effective medium theory-based transfer matrix method have been independently developed to analyze the performance of the nano-composite absorption layer. We show that inserting 15% volume fraction Ni nanoparticles into 40-nm of TaN absorber material can reduce the reflection below 2% over the EUV range. Numerical simulations confirm that the reduced reflectivity is due to the increased absorption of Ni, while scattering only contributes to approximately 0.2% of the reduction in reflectivity.

  9. Independent polarization and multi-band THz absorber base on Jerusalem cross

    NASA Astrophysics Data System (ADS)

    Arezoomand, Afsaneh Saee; Zarrabi, Ferdows B.; Heydari, Samaneh; Gandji, Navid P.

    2015-10-01

    In this paper, we present the design and simulation of a single and multi-band perfect metamaterial absorber (MA) in the THz region base on Jerusalem cross (JC) and metamaterial load in unit cells. The structures consist of dual metallic layers for allowing near-perfect absorption with absorption peak of more than 99%. In this novel design, four-different shape of Jerusalem cross is presented and by adding L, U and W shape loaded to first structure, we tried to achieve a dual-band absorber. In addition, by good implementation of these loaded, we are able to control the absorption resonance at second resonance at 0.9, 0.7 and 0.85 THz respectively. In the other hand, we achieved a semi stable designing at first resonance between 0.53 and 0.58 THz. The proposed absorber has broadband polarization angle. The surface current modeled and proved the broadband polarization angle at prototype MA. The LC resonance of the metamaterial for Jerusalem cross and modified structures are extracting from equivalent circuit. As a result, proposed MA is useful for THz medical imaging and communication systems and the dual-band absorber has applications in many scientific and technological areas.

  10. Solid analyte and aqueous solutions sensing based on a flexible terahertz dual-band metamaterial absorber

    NASA Astrophysics Data System (ADS)

    Yan, Xin; Liang, Lan-Ju; Ding, Xin; Yao, Jian-Quan

    2017-02-01

    A high-sensitivity sensing technique was demonstrated based on a flexible terahertz dual-band metamaterial absorber. The absorber has two perfect absorption peaks, one with a fundamental resonance (f1) of the structure and another with a high-order resonance (f2) originating from the interactions of adjacent unit cells. The quality factor (Q) and figure of merit of f2 are 6 and 14 times larger than that of f1, respectively. For the solid analyte, the changes in resonance frequency are monitored upon variation of analyte thickness and index; a linear relation between the amplitude absorption with the analyte thickness is achieved for f2. The sensitivity (S) is 31.2% refractive index units (RIU-1) for f2 and 13.7% RIU-1 for f1. For the aqueous solutions, the amplitude of absorption decreases linearly with increasing the dielectric constant for the ethanol-water mixture of f1. These results show that the designed absorber cannot only identify a solid analyte but also characterize aqueous solutions through the frequency shift and amplitude absorption. Therefore, the proposed absorber is promising for future applications in high-sensitivity monitoring biomolecular, chemical, ecological water systems, and aqueous biosystems.

  11. Broadband, polarization-insensitive, and wide-angle microwave absorber based on resistive film

    NASA Astrophysics Data System (ADS)

    Dan-Dan, Bu; Chun-Sheng, Yue; Guang-Qiu, Zhang; Yong-Tao, Hu; Sheng, Dong

    2016-06-01

    A simple design of broadband metamaterial absorber (MA) based on resistive film is numerically presented in this paper. The unit cell of this absorber is composed of crossed rectangular rings-shaped resistive film, dielectric substrate, and continuous metal film. The simulated results indicate that the absorber obtains a 12.82-GHz-wide absorption from about 4.75 GHz to 17.57 GHz with absorptivity over 90% at normal incidence. Distribution of surface power loss density is illustrated to understand the intrinsic absorption mechanism of the structure. The proposed structure can work at wide polarization angles and wide angles of incidence for both transverse electric (TE) and transverse magnetic (TM) waves. Finally, the multi-reflection interference theory is involved to analyze and explain the broadband absorption mechanism at both normal and oblique incidence. Moreover, the polarization-insensitive feature is also investigated by using the interference model. It is seen that the simulated and calculated absorption rates agree fairly well with each other for the absorber.

  12. Integration of an interferometric IR absorber into an epoxy membrane based CO2 detector

    NASA Astrophysics Data System (ADS)

    Ashraf, S.; Mattsson, C. G.; Thungström, G.; Rödjegård, H.

    2014-05-01

    Measurements of carbon dioxide levels in the environment are commonly performed by using non-dispersive infrared technology (NDIR). Thermopile detectors are often used in NDIR systems because of their non-cooling advantages. The infrared absorber has a major influence on the detector responsivity. In this paper, the fabrication of a SU-8 epoxy membrane based Al/Bi thermopile detector and the integration of an interferometric infrared absorber structure of wavelength around 4 μm into the detector is reported. The membrane of thermopile detector has been utilized as a dielectric medium in an interferometric absorption structure. By doing so, a reduction in both thermal conductance and capacitance is achieved. In the fabrication of the thermopile, metal evaporation and lift off process had been used for the deposition of serially interconnected Al/Bi thermocouples. Serial resistance of fabricated thermopile was measured as 220 kΩ. The response of fabricated thermopile detector was measured using a visible to infrared source of radiation flux 3.23 mW mm-2. The radiation incident on the detector was limited using a band pass filter of wavelength 4.26 μm in front of the detector. A responsivity of 27.86 V mm2 W-1 at room temperature was achieved using this setup. The fabricated detector was compared to a reference detector with a broad band absorber. From the comparison it was concluded that the integrated interferometric absorber is functioning correctly.

  13. Intensity tunable infrared broadband absorbers based on VO2 phase transition using planar layered thin films

    PubMed Central

    Kocer, Hasan; Butun, Serkan; Palacios, Edgar; Liu, Zizhuo; Tongay, Sefaattin; Fu, Deyi; Wang, Kevin; Wu, Junqiao; Aydin, Koray

    2015-01-01

    Plasmonic and metamaterial based nano/micro-structured materials enable spectrally selective resonant absorption, where the resonant bandwidth and absorption intensity can be engineered by controlling the size and geometry of nanostructures. Here, we demonstrate a simple, lithography-free approach for obtaining a resonant and dynamically tunable broadband absorber based on vanadium dioxide (VO2) phase transition. Using planar layered thin film structures, where top layer is chosen to be an ultrathin (20 nm) VO2 film, we demonstrate broadband IR light absorption tuning (from ~90% to ~30% in measured absorption) over the entire mid-wavelength infrared spectrum. Our numerical and experimental results indicate that the bandwidth of the absorption bands can be controlled by changing the dielectric spacer layer thickness. Broadband tunable absorbers can find applications in absorption filters, thermal emitters, thermophotovoltaics and sensing. PMID:26294085

  14. Knitted radar absorbing materials (RAM) based on nickel-cobalt magnetic materials

    NASA Astrophysics Data System (ADS)

    Teber, Ahmet; Unver, Ibrahim; Kavas, Huseyin; Aktas, Bekir; Bansal, Rajeev

    2016-05-01

    There has been a long-standing interest in the development of flexible, lightweight, thin, and reconfigurable radar absorbing materials (RAM) for military applications such as camouflaging ground-based hardware against airborne radar observation. The use of polymeric Polyacrylonitrile (PAN) fabrics as a host matrix for magnetic metal nano-particles (either at the yarn-stage or after weaving the fabric) for shielding and absorbing applications has been described in the literature. In our experimental investigation, the relative concentrations of Nickel and Cobalt as well as the coating time are varied with a view to optimizing the microwave absorption characteristics of the resulting PAN-based composite material in the radar-frequency bands (X, Ku, and K). It is found that the PAN samples with the shortest coating time have the best return losses (under -20 dB return loss over a moderate bandwidth).

  15. A surface micromachined thermopile detector array with an interference-based absorber

    NASA Astrophysics Data System (ADS)

    Wu, H.; Emadi, A.; Sarro, P. M.; de Graaf, G.; Wolffenbuttel, R. F.

    2011-07-01

    A thermo-electric (TE) infrared detector array composed of 23 thermopiles, each with 5 thermocouples on a suspended beam of 650 × 36 µm2 dimensions, has been fabricated in a CMOS-compatible MEMS process. The array is used for realization of an IR micro-spectrometer in the 1-5 µm spectral range. Interference filter-based IR absorbers using titanium/aluminum layers with a silicon carbide cavity layer have been designed, fabricated and validated. These thin film stacks are more suitable for the subsequent processes as compared to conventional techniques. The silicon carbide layer is also used for device protection. The TE detector with an interference filter-based absorber features a sensitivity of 294 V W-1 in the 2.15 µm wavelength range and a thermal time constant of 4.85 ms in vacuum.

  16. Adjustable low frequency and broadband metamaterial absorber based on magnetic rubber plate and cross resonator

    NASA Astrophysics Data System (ADS)

    Cheng, Yongzhi; Nie, Yan; Wang, Xian; Gong, Rongzhou

    2014-02-01

    In this paper, the magnetic rubber plate absorber (MRPA) and metamaterial absorber (MA) based on MRP substrate were proposed and studied numerically and experimentally. Based on the characteristic of L-C resonances, experimental results show that the MA composed of cross resonator (CR) embedded single layer MRP could be adjustable easily by changing the wire length and width of CR structure and MRP thickness. Finally, experimental results show that the MA composed of CR-embedded two layers MRP with the total thickness of 2.42 mm exhibit a -10 dB absorption bandwidth from 1.65 GHz to 3.7 GHz, which is 1.86 times wider than the same thickness MRPA.

  17. CMOS-compatible fabrication of metamaterial-based absorbers for the mid-IR spectral range

    NASA Astrophysics Data System (ADS)

    Karimi Shahmarvandi, Ehsan; Ghaderi, Mohammadamir; Wolffenbuttel, Reinoud F.

    2016-10-01

    A CMOS-compatible approach is presented for the fabrication of a wideband mid-IR metamaterial-based absorber on top of a Si3N4 membrane, which contains poly-Si thermopiles. The application is in IR microspectrometers that are intended for implementation in portable microsystem for use in absorption spectroscopy. Although Au is the conventional material of choice, we demonstrate by simulation that near-perfect absorption can be achieved over a wider band when using the more CMOS-compatible Al. The absorber design is based on Al disk resonators and an Al backplane, which are separated by a SiO2 layer. The fabrication process involves the deposition of Al and SiO2 layers on top of a Si3N4 membrane, lithography and a lift-off process for patterning of the top Al layer.

  18. Calculation of absorbed dose around a facility for disposing of low activity natural radioactive waste (C3-dump).

    PubMed

    Jansen, J T M; Zoetelief, J

    2005-01-01

    A C3-dump is a facility for disposing of low activity natural radioactive waste containing the uranium series 238U, the thorium series 232Th and 40K. Only the external radiation owing to gamma rays, X-rays and annihilation photons is considered in this study. For two situations--the semi-infinite slab and the tourist geometry--the conversion coefficients from specific activity to air kerma rate at 1 m above the relevant level are calculated. In the first situation the waste material is in contact with the air but in the tourist geometry it is covered with a 1.35 m thick layer. For the calculations, the Monte Carlo radiation transport code MCNP is used. The yield and photon energy for each radionuclide are according to the database of Oak Ridge National Laboratory. For the tourist situation, the depth-dose distribution through the covering layer is calculated and extrapolated to determine the exit dose.

  19. Assembling and Using an LED-Based Detector to Monitor Absorbance Changes during Acid-Base Titrations

    ERIC Educational Resources Information Center

    Santos, Willy G.; Cavalheiro, E´der T. G.

    2015-01-01

    A simple photometric assembly based in an LED as a light source and a photodiode as a detector is proposed in order to follow the absorbance changes as a function of the titrant volume added during the course of acid-base titrations in the presence of a suitable visual indicator. The simplicity and low cost of the electronic device allow the…

  20. Experimental assessment of absorbed dose to mineralized bone tissue from internal emitters: An electron paramagnetic resonance study

    SciTech Connect

    Desrosiers, M.F.

    1994-12-31

    EPR resonances attributable to radiation-induced centers in hydroxyapatite were not detectable in bone samples supplied by the USTUR. These centers are the basis for imaging and dose assessment. Presumable, the short range of the alpha particles emitted precluded the formation of appreciable amounts of hydroxyapatite centers. However, one bone sample did offer a suggestion of hydroxyapatite centers and newly-developed methods to extract this information will be pursued.

  1. PHITS simulations of the Protective curtain experiment onboard the Service module of ISS: Comparison with absorbed doses measured with TLDs

    NASA Astrophysics Data System (ADS)

    Ploc, Ondřej; Sihver, Lembit; Kartashov, Dmitry; Shurshakov, Vyacheslav; Tolochek, Raisa

    2013-12-01

    "Protective curtain" was the physical experiment onboard the International Space Station (ISS) aimed on radiation measurement of the dose - reducing effect of the additional shielding made of hygienic water-soaked wipes and towels placed on the wall in the crew cabin of the Service module Zvezda. The measurements were performed with 12 detector packages composed of thermoluminescent detectors (TLDs) and plastic nuclear track detectors (PNTDs) placed at the Protective curtain, so that they created pairs of shielded and unshielded detectors.

  2. Saturable absorber based on silver nanoparticles for passively mode-locked lasers

    SciTech Connect

    Glubokov, D A; Sychev, V V; Korolkov, A E; Chubich, D A; Vitukhnovskii, A G; Mikhailov, A S; Shapiro, B I

    2014-04-28

    A saturable absorber based on plane (tabular) stabilised silver nanocrystals, which is promising for picoseconds laser systems operating in the range 650–900 nm, is studied. This material has a plasmon decay time of about 2 ps, while its absorption at a pump intensity of 10 MW cm{sup -2} decreases by 1.6%, which is sufficient for using this crystal for passive mode locking. (control of laser radiation parameters)

  3. CMOS-compatible metamaterial-based wideband mid-infrared absorber for microspectrometer applications

    NASA Astrophysics Data System (ADS)

    Karimi Shahmarvandi, Ehsan; Ghaderi, Mohammadamir; Ayerden, N. Pelin; de Graaf, Ger; Wolffenbuttel, Reinoud F.

    2016-04-01

    The design of a metamaterial-based absorber for use in a MEMS-based mid-IR microspectrometer is reported. The microspectrometer consists of a LVOF that is aligned with an array of thermopile detectors, which is fabricated on a SiN membrane and coated with the absorber. Special emphasis is put on the CMOS compatible fabrication, which results in an absorber design based on Al disc resonators and an Al background plane that are separated by an SiO2 layer. Wideband operation over the 3-4 μm spectral range is achieved by staggered tuning of four Al disk resonators in one 1.5 x 1.5 μm2 unit cell, using four different values of the radius of the Al disk between 0.50 μm and 0.63 μm and an SiO2 layer thickness of 150 nm. Simulations reveal an average absorption of about 95% with a +/-4% ripple at normal incidence, which reduces to about 80% absorption at a 20° incidence angle. The influence of material choice and dimensions on a single absorption peak was studied and the magnetic polariton was identified as the underlying mechanism of absorption.

  4. An antibacterial and absorbable silk-based fixation material with impressive mechanical properties and biocompatibility

    PubMed Central

    Shi, Chenglong; Pu, Xiaobing; Zheng, Guan; Feng, Xinglong; Yang, Xuan; Zhang, Baoliang; Zhang, Yu; Yin, Qingshui; Xia, Hong

    2016-01-01

    Implant-associated infections and non-absorbing materials are two important reasons for a second surgical procedure to remove internal fixation devices after an orthopedic internal fixation surgery. The objective of this study was to produce an antibacterial and absorbable fixation screw by adding gentamicin to silk-based materials. The antibacterial activity was assessed against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) in vitro by plate cultivation and scanning electron microscopy (SEM). We also investigated the properties, such as the mechanical features, swelling properties, biocompatibility and degradation, of gentamicin-loaded silk-based screws (GSS) in vitro. The GSS showed significant bactericidal effects against S. aureus and E. coli. The antibacterial activity remained high even after 4 weeks of immersion in protease solution. In addition, the GSS maintained the remarkable mechanical properties and excellent biocompatibility of pure silk-based screws (PSS). Interestingly, after gentamicin incorporation, the degradation rate and water-absorbing capacity increased and decreased, respectively. These GSS provide both impressive material properties and antibacterial activity and have great potential for use in orthopedic implants to reduce the incidence of second surgeries. PMID:27869175

  5. An antibacterial and absorbable silk-based fixation material with impressive mechanical properties and biocompatibility

    NASA Astrophysics Data System (ADS)

    Shi, Chenglong; Pu, Xiaobing; Zheng, Guan; Feng, Xinglong; Yang, Xuan; Zhang, Baoliang; Zhang, Yu; Yin, Qingshui; Xia, Hong

    2016-11-01

    Implant-associated infections and non-absorbing materials are two important reasons for a second surgical procedure to remove internal fixation devices after an orthopedic internal fixation surgery. The objective of this study was to produce an antibacterial and absorbable fixation screw by adding gentamicin to silk-based materials. The antibacterial activity was assessed against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) in vitro by plate cultivation and scanning electron microscopy (SEM). We also investigated the properties, such as the mechanical features, swelling properties, biocompatibility and degradation, of gentamicin-loaded silk-based screws (GSS) in vitro. The GSS showed significant bactericidal effects against S. aureus and E. coli. The antibacterial activity remained high even after 4 weeks of immersion in protease solution. In addition, the GSS maintained the remarkable mechanical properties and excellent biocompatibility of pure silk-based screws (PSS). Interestingly, after gentamicin incorporation, the degradation rate and water-absorbing capacity increased and decreased, respectively. These GSS provide both impressive material properties and antibacterial activity and have great potential for use in orthopedic implants to reduce the incidence of second surgeries.

  6. Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and {sup 60}Co γ-rays

    SciTech Connect

    Vadrucci, M. Ronsivalle, C.; Marracino, F.; Montereali, R. M.; Picardi, L.; Piccinini, M.; Vincenti, M. A.; Esposito, G.; De Angelis, C.; Cherubini, R.; Pimpinella, M.

    2015-08-15

    Purpose: To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference {sup 60}Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. Methods: EBT3 film samples were irradiated at the Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Legnaro, Italy, with a 5 MeV proton beam generated by a 7 MV Van de Graaff CN accelerator. The nominal dose rates used were 2.1 Gy/min and 40 Gy/min. The delivered dose was determined by measuring the particle fluence and the energy spectrum in air with silicon surface barrier detector monitors. A preliminary study of the EBT3 film beam quality dependence in low-energy protons was conducted by passively degrading the beam energy. EBT3 films were also irradiated at ENEA-National Institute of Ionizing Radiation Metrology with gamma radiation produced by a {sup 60}Co source characterized by an absorbed dose to water rate of 0.26 Gy/min as measured by a calibrated Farmer type ionization chamber. EBT3 film calibration curves were determined by means of a set of 40 film pieces irradiated to various doses ranging from 0.5 Gy to 30 Gy absorbed dose to water. An EPSON Expression 11000XL color scanner in transmission mode was used for film analysis. Scanner response stability, intrafilm uniformity, and interfilm reproducibility were verified. Optical absorption spectra measurements were performed on unirradiated and irradiated EBT3 films to choose the most sensitive color channel to the dose range used. Results: EBT3 GafChromic films show an under response up to about 33% for low-energy protons with respect to {sup 60}Co gamma radiation, which is consistent with the linear energy transfer dependence already observed with higher energy protons, and a negligible dose

  7. A wide-angle broadband absorber in graphene-based hyperbolic metamaterials

    NASA Astrophysics Data System (ADS)

    Ning, Renxia; Liu, Shaobin; Zhang, Haifeng; Bian, Borui; Kong, Xiangkun

    2014-11-01

    A wide-angle broadband absorber which is realized by periodic structures containing graphene-based hyperbolic metamaterials (GHMM) and isotropic medium is theoretically investigated. The GHMM is composed of monolayer graphene and conventional dielectric, which the refractive index can be tuned by the chemical potential, the thickness of dielectric and phenomenological scattering rates, respectively. A periodic structure of GHMM can obtain a broadband absorption which is shown to absorb roughly 70% (relative bandwidth is larger than 45%) of all available electromagnetic wave in absorption bandwidth at normal incident angle. Compared with some previous designs, our proposed structure has a relative bandwidth over a broad frequency range in mid-infrared. This kind periodic structures offer additional opportunities to design novel optoelectronic devices.

  8. Ultrabroadband Microwave Metamaterial Absorber Based on Electric SRR Loaded with Lumped Resistors

    NASA Astrophysics Data System (ADS)

    Zhao, Jingcheng; Cheng, Yongzhi

    2016-10-01

    An ultrabroadband microwave metamaterial absorber (MMA) based on an electric split-ring resonator (ESRR) loaded with lumped resistors is presented. Compared with an ESRR MMA, the composite MMA (CMMA) loaded with lumped resistors offers stronger absorption over an extremely extended bandwidth. The reflectance simulated under different substrate loss conditions indicates that incident electromagnetic (EM) wave energy is mainly consumed by the lumped resistors. The simulated surface current and power loss density distributions further illustrate the mechanism underlying the observed absorption. Further simulation results indicate that the performance of the CMMA can be tuned by adjusting structural parameters of the ESRR and lumped resistor parameters. We fabricated and measured MMA and CMMA samples. The CMMA yielded below -10 dB reflectance from 4.4 GHz to 18 GHz experimentally, with absorption bandwidth and relative bandwidth of 13.6 GHz and 121.4%, respectively. This ultrabroadband microwave absorber has potential applications in the electromagnetic energy harvesting and stealth fields.

  9. [Decision-making while implantation of biodegradable vascular scaffolds ABSORB based on methods of intravascular visualization].

    PubMed

    Buzaev, I V; Plechev, V V; Nikolaeva, I E; Zagitov, I G; Oleĭnik, B A

    A series of studies demonstrated comparability of the incidence rate of major adverse cardiac events (MACE) in the middle-term postoperative period following implantation of last-generation drug-coated stents and biodegradable intravascular scaffolds. It was noted observed that these complications may be associated with malposition and inadequate inappropriate preparation of the lesion. We carried out a total of 16 percutaneous coronary interventions (PCI) with implantation of absorbable vascular scaffolds (Absorb, Abbott Vascular) under the guidance of optical coherent tomography. Besides, a further 16 PCIs were performed without intravascular visualization (control group). As experience was gathered, the algorithm of carrying out optical coherent tomography was subjected to changes, resulting in proposal of an optimal algorithm for choice of intraoperative policy based on the findings obtained in optical coherent tomography.

  10. Kevlar based nanofibrous particles as robust, effective and recyclable absorbents for water purification.

    PubMed

    Nie, Chuanxiong; Peng, Zihang; Yang, Ye; Cheng, Chong; Ma, Lang; Zhao, Changsheng

    2016-11-15

    Developing robust and recyclable absorbents for water purification is of great demand to control water pollution and to provide sustainable water resources. Herein, for the first time, we reported the fabrication of Kevlar nanofiber (KNF) based composite particles for water purification. Both the KNF and KNF-carbon nanotube composite particles can be produced in large-scale by automatic injection of casting solution into ethanol. The resulted nanofibrous particles showed high adsorption capacities towards various pollutants, including metal ions, phenylic compounds and various dyes. Meanwhile, the adsorption process towards dyes was found to fit well with the pseudo-second-order model, while the adsorption speed was controlled by intraparticle diffusion. Furthermore, the adsorption capacities of the nanofibrous particles could be easily recovered by washing with ethanol. In general, the KNF based particles integrate the advantages of easy production, robust and effective adsorption performances, as well as good recyclability, which can be used as robust absorbents to remove toxic molecules and forward the application of absorbents in water purification.

  11. Complex absorbing potential based Lorentzian fitting scheme and time dependent quantum transport.

    PubMed

    Xie, Hang; Kwok, Yanho; Jiang, Feng; Zheng, Xiao; Chen, GuanHua

    2014-10-28

    Based on the complex absorbing potential (CAP) method, a Lorentzian expansion scheme is developed to express the self-energy. The CAP-based Lorentzian expansion of self-energy is employed to solve efficiently the Liouville-von Neumann equation of one-electron density matrix. The resulting method is applicable for both tight-binding and first-principles models and is used to simulate the transient currents through graphene nanoribbons and a benzene molecule sandwiched between two carbon-atom chains.

  12. Complex absorbing potential based Lorentzian fitting scheme and time dependent quantum transport

    SciTech Connect

    Xie, Hang Kwok, Yanho; Chen, GuanHua; Jiang, Feng; Zheng, Xiao

    2014-10-28

    Based on the complex absorbing potential (CAP) method, a Lorentzian expansion scheme is developed to express the self-energy. The CAP-based Lorentzian expansion of self-energy is employed to solve efficiently the Liouville-von Neumann equation of one-electron density matrix. The resulting method is applicable for both tight-binding and first-principles models and is used to simulate the transient currents through graphene nanoribbons and a benzene molecule sandwiched between two carbon-atom chains.

  13. Low-frequency and broadband metamaterial absorber based on lumped elements: design, characterization and experiment

    NASA Astrophysics Data System (ADS)

    Yuan, Wenshan; Cheng, Yongzhi

    2014-12-01

    In this paper, we propose and experimentally validate a low-frequency metamaterial absorber (MMA) based on lumped elements with broadband stronger absorptivity in the microwave regime. Compared with the electric resonator structure MMA, the composite MMA (CMMA) loaded with lumped elements has stronger absorptivity and nearly impedance-matched to the free space in a broadband frequency range. The simulated voltage in lumped elements and the absorbance under different substrate loss conditions indicate that incident electromagnetic wave energy is mainly transformed to electric energy in the absorption band with high efficiency and subsequently consumed by lumped resistors. Simulated surface current and power loss density distributions further clarify the mechanism underlying observed absorption. The CMMA also shows a polarization-insensitive and wide-angle strong absorption. Finally, we fabricate and measure the MMA and CMMA samples. The CMMA yields below -10 dB reflectance from 2.85 to 5.31 GHz in the experiment, and the relative bandwidth is about 60.3 %. This low-frequency microwave absorber has potential applications in many martial fields.

  14. Design and Development of Expanded Graphite-Based Non-metallic and Flexible Metamaterial Absorber for X-band Applications

    NASA Astrophysics Data System (ADS)

    Borah, Dipangkar; Bhattacharyya, Nidhi S.

    2017-01-01

    The possibility of using expanded graphite instead of a metallic layer as unit cells and ground planes for metamaterial absorbers in X-band is investigated. A metamaterial absorber was fabricated on a flexible linear low-density polyethylene substrate using an expanded graphite-based circular ring as the unit cell structure. The unit cell was simulated and optimized for which the metamaterial absorber exhibited 98.9% absorption at 11.22 GHz. The fabricated expanded graphite-based absorber showed a reflection loss of -24.51 dB at 11.56 GHz with -10 dB bandwidth of 0.39 GHz (3.37%). The performance of the same structure with copper was also measured. The expanded graphite-based metamaterial absorber showed enhanced performance as compared to the copper-based metamaterial absorber. The width of the ring was varied to tune the reflection loss. The proposed expanded graphite-based metamaterial absorber possesses the advantages of being ultra-thin, flexible and non-corrosive.

  15. The biodistribution and dosimetry of {sup 117m}Sn DTPA with special emphasis on active marrow absorbed doses

    SciTech Connect

    Stubbs, J.; Atkins, H.

    1999-01-01

    {sup 117m}Sn(4+) DTPA is a new radiopharmaceutical for the palliation of pain associated with metastatic bone cancer. Recently, the Phase 2 clinical trials involving 47 patients were completed. These patients received administered activities in the range 6.7--10.6 MBq/kg of body mass. Frequent collections of urine were acquired over the first several hours postadministration and daily cumulative collections were obtained for the next 4--10 days. Anterior/posterior gamma camera images were obtained frequently over the initial 10 days. Radiation dose estimates were calculated for 8 of these patients. Each patient`s biodistribution data were mathematically simulated using a multicompartmental model. The model consisted of the following compartments: central, bone, kidney, other tissues, and cumulative urine. The measured cumulative urine data were used as references for the cumulative urine excretion compartment. The total-body compartment (sum of the bone surfaces, central, kidney, and other tissues compartments) was reference to all activity not excreted in the urine.

  16. Fluence-to-Absorbed Dose Conversion Coefficients for Use in Radiological Protection of Embryo and Foetus Against External Exposure to Muons from 20MeV to 50GeV

    SciTech Connect

    Chen Jing

    2008-08-07

    This study used the Monte-Carlo code MCNPX to determine mean absorbed doses to the embryo and foetus when the mother is exposed to external muon fields. Monoenergetic muons ranging from 20 MeV to 50 GeV were considered. The irradiation geometries include anteroposterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT), isotropic (ISO), and top-down (TOP). At each of these irradiation geometries, absorbed doses to the foetal body were calculated for the embryo of 8 weeks and the foetus of 3, 6 or 9 months, respectively. Muon fluence-to-absorbed-dose conversion coefficients were derived for the four prenatal ages. Since such conversion coefficients are yet unknown, the results presented here fill a data gap.

  17. EURAMET.RI(I)-S7 comparison of alanine dosimetry systems for absorbed dose to water measurements in gamma- and x-radiation at radiotherapy levels

    NASA Astrophysics Data System (ADS)

    Garcia, Tristan; Anton, Mathias; Sharpe, Peter

    2012-01-01

    The National Physical Laboratory (NPL), the Physikalisch-Technische Bundesanstalt (PTB) and the Laboratoire National Henri Becquerel (LNE-LNHB) are involved in the European project 'External Beam Cancer Therapy', a project of the European Metrology Research Programme. Within this project, the electron paramagnetic resonance (EPR)/alanine dosimetric method has been chosen for performing measurements in small fields such as those used in IMRT (intensity modulated radiation therapy). In this context, these three National Metrology Institutes (NMI) wished to compare the result of their alanine dosimetric systems (detector, modus operandi etc) at radiotherapy dose levels to check their consistency. This EURAMET.RI(I)-S7 comparison has been performed with the support of the Bureau International des Poids et Mesures (BIPM) which collected and distributed the results as a neutral organization, to ensure the comparison was 'blind'. Irradiations have been made under reference conditions by each laboratory in a 60Co beam and in an accelerator beam (10 MV or 12 MV) in a water phantom of 30 cm × 30 cm × 30 cm in a square field of 10 cm × 10 cm at the reference depth. Irradiations have been performed at known values of absorbed dose to water (Dw) within 10% of nominal doses of 5 Gy and 10 Gy, i.e. between 4.5 Gy and 5.5 Gy and between 9 Gy and 11 Gy, respectively. Each participant read out their dosimeters and assessed the doses using their own protocol (calibration curve, positioning device etc) as this comparison aims at comparing the complete dosimetric process. The results demonstrate the effectiveness of the EPR/alanine dosimetry systems operated by National Metrology Institutes as a method of assuring therapy level doses with the accuracy required. The maximum deviation in the ratio of measured to applied dose is less than 1%. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key

  18. Measurement of the depth distribution of average LET and absorbed dose inside a water-filled phantom on board space station MIR.

    PubMed

    Berger, T; Hajek, M; Schoner, W; Fugger, M; Vana, N; Noll, M; Ebner, R; Akatov, Y; Shurshakov, V; Arkhangelsky, V

    2001-01-01

    The Atominstitute of the Austrian Universities developed the HTR-method for determination of absorbed dose and "averaged" linear energy transfer (LET) in mixed radiation fields. The method was applied with great success during several space missions (e.g. STS-60, STS-63, BION-10 and BION-11) and on space station MIR in the past 10 years. It utilises the changes of peak height ratios in LiF thermoluminescent glowcurves in dependence on the LET. Due to the small size of these dosemeters the HTR-method can be used also for measurements inside tissue equivalent phantoms. A water filled phantom with a diameter of 35 cm containing four channels where dosemeters can be exposed in different depths was developed by the Institute for Biomedical Problems. This opens the possibility to measure the depth distribution of the average LET and the dose equivalent simultaneously. During phase 1 dosemeters were exposed for 271 days (05.1997-02.1998) in 6 different depths inside the phantom, which was positioned in the commander cabin. In phase 2 dosemeters were exposed in 2 channels in 6 different depths for 102 days (05.1998-08.1998) in the board engineer cabin, following an exposure in different channels in 3 different depths for 199 days (08.1998- 02.1999) in the Modul KWANT 2.

  19. Estimates of lifetime-absorbed daily doses from the use of personal-care products containing polyacrylamide: a Monte Carlo analysis.

    PubMed

    Van Landingham, Cynthia B; Lawrence, Greg A; Shipp, Annette M

    2004-06-01

    Estimates of the lifetime-absorbed daily dose (LADD) of acrylamide resulting from use of representative personal-care products containing polyacrylamides have been developed. All of the parameters that determine the amount of acrylamide absorbed by an individual vary from one individual to another. Moreover, for some parameters there is uncertainty as to which is the correct or representative value from a range of values. Consequently, the parameters used in the estimation of the LADD of acrylamide from usage of a particular product type (e.g., deodorant, makeup, etc.) were represented by distributions evaluated using Monte Carlo analyses.((1-4)) From these data, distributions of values for key parameters, such as the amount of acrylamide in polyacrylamide, absorption fraction, etc., were defined and used to provide a distribution of LADDs for each personal-care product. The estimated total acrylamide LADD (across all products) for males and females at the median, mean, and 95th percentile of the distribution of individual LADD values were 4.7 x 10(-8), 2.3 x 10(-7), and 7.3 x 10(-7) mg/kg/day for females and 3.6 x 10(-8), 1.7 x 10(-7), and 5.4 x 10(-7) mg/kg/day for males. The ratio of the LADDs to risk-specific dose corresponding to a target risk level of 1 x 10(-5), the acceptable risk level for this investigation, derived using approaches typically used by the FDA, the USEPA, and proposed for use by the European Union (EU) were also calculated. All ratios were well below 1, indicating that all the extra lifetime cancer risk from the use of polyacrylamide-containing personal-care products, in the manner assumed in this assessment, are well below acceptable levels. Even if it were assumed that an individual used all of the products together, the estimated LADD would still provide a dose that was well below the acceptable risk levels.

  20. Three-dimensional assessment of the effects of high-density embolization material on the absorbed dose in the target for Gamma Knife radiosurgery of arteriovenous malformations.

    PubMed

    Watanabe, Yoichi; Sandhu, Divyajot; Warmington, Leighton; Moen, Sean; Tummala, Ramachandra

    2016-12-01

    OBJECTIVE Arteriovenous malformation (AVM) is an intracranial vascular disorder. Gamma Knife radiosurgery (GKRS) is used in conjunction with intraarterial embolization to eradicate the nidus of AVMs. Clinical results indicate that patients with prior embolization tend to gain less benefit from GKRS. The authors hypothesized that this was partly caused by dosimetric deficiency. The actual dose delivered to the target may be smaller than the intended dose because of increased photon attenuation by high-density embolic materials. The authors performed a phantom-based study to quantitatively evaluate the 3D dosimetric effect of embolic material on GKRS. METHODS A 16-cm-diameter and 12-cm-long cylindrical phantom with a 16-cm-diameter hemispherical dome was printed by a 3D printer. The phantom was filled with radiologically tissue-equivalent polymer gel. To simulate AVM treatment with embolization, phantoms contained Onyx 18. The material was injected into an AVM model, which was suspended in the polymer gel. The phantom was attached to a Leksell frame by standard GK fixation method, using aluminum screws, for imaging. The phantom was scanned by a Phillips CT scanner with the standard axial-scanning protocol (120 kV and 1.5-mm slice thickness). CT-based treatment planning was performed with the GammaPlan treatment planning system (version 10.1.1). The plan was created to cover a fictitious AVM target volume near the embolization areas with eleven 8-mm shots and a prescription dose of 20 Gy to 50% isodose level. Dose distributions were computed using both tissue maximum ratio (TMR) 10 and convolution dose-calculation algorithms. These two 3D dose distributions were compared using an in-house program. Additionally, the same analysis method was applied to evaluate the dosimetric effects for 2 patients previously treated by GKRS. RESULTS The phantom-based analyses showed that the mean dose difference between TMR 10 and convolution doses of the AVM target was no larger than

  1. On effective dose for radiotherapy based on doses to nontarget organs and tissues

    SciTech Connect

    Uselmann, Adam J. Thomadsen, Bruce R.

    2015-02-15

    Purpose: The National Council for Radiation Protection and Measurement (NCRP) published estimates for the collective population dose and the mean effective dose to the population of the United States from medical imaging procedures for 1980/1982 and for 2006. The earlier report ignored the effective dose from radiotherapy and the latter gave a cursory discussion of the topic but again did not include it in the population exposure for various reasons. This paper explains the methodology used to calculate the effective dose in due to radiotherapy procedures in the latter NCRP report and revises the values based on more detailed modeling. Methods: This study calculated the dose to nontarget organs from radiotherapy for reference populations using CT images and published peripheral dose data. Results: Using International Commission on Radiological Protection (ICRP) 60 weighting factors, the total effective dose to nontarget organs in radiotherapy patients is estimated as 298 ± 194 mSv per patient, while the U.S. population effective dose is 0.939 ± 0.610 mSv per person, with a collective dose of 283 000 ± 184 000 person Sv per year. Using ICRP 103 weighting factors, the effective dose is 281 ± 183 mSv per patient, 0.887 ± 0.577 mSv per person in the U.S., and 268 000 ± 174 000 person Sv per year. The uncertainty in the calculations is largely governed by variations in patient size, which was accounted for by considering a range of patient sizes and taking the average treatment site to nontarget organ distance. Conclusions: The methods used to estimate the effective doses from radiotherapy used in NCRP Report No. 160 have been explained and the values updated.

  2. Photon dose calculation based on electron multiple-scattering theory: primary dose deposition kernels.

    PubMed

    Wang, L; Jette, D

    1999-08-01

    The transport of the secondary electrons resulting from high-energy photon interactions is essential to energy redistribution and deposition. In order to develop an accurate dose-calculation algorithm for high-energy photons, which can predict the dose distribution in inhomogeneous media and at the beam edges, we have investigated the feasibility of applying electron transport theory [Jette, Med. Phys. 15, 123 (1988)] to photon dose calculation. In particular, the transport of and energy deposition by Compton electron and electrons and positrons resulting from pair production were studied. The primary photons are treated as the source of the secondary electrons and positrons, which are transported through the irradiated medium using Gaussian multiple-scattering theory [Jette, Med. Phys. 15, 123 (1988)]. The initial angular and kinetic energy distribution(s) of the secondary electrons (and positrons) emanating from the photon interactions are incorporated into the transport. Due to different mechanisms of creation and cross-section functions, the transport of and the energy deposition by the electrons released in these two processes are studied and modeled separately based on first principles. In this article, we focus on determining the dose distribution for an individual interaction site. We define the Compton dose deposition kernel (CDK) or the pair-production dose deposition kernel (PDK) as the dose distribution relative to the point of interaction, per unit interaction density, for a monoenergetic photon beam in an infinite homogeneous medium of unit density. The validity of this analytic modeling of dose deposition was evaluated through EGS4 Monte Carlo simulation. Quantitative agreement between these two calculations of the dose distribution and the average energy deposited per interaction was achieved. Our results demonstrate the applicability of the electron dose-calculation method to photon dose calculation.

  3. Enhanced performance of VOx-based bolometer using patterned gold black absorber

    NASA Astrophysics Data System (ADS)

    Smith, Evan M.; Panjwani, Deep; Ginn, James; Warren, Andrew; Long, Christopher; Figuieredo, Pedro; Smith, Christian; Perlstein, Joshua; Walter, Nick; Hirschmugl, Carol; Peale, Robert E.; Shelton, David J.

    2015-06-01

    Patterned highly absorbing gold black film has been selectively deposited on the active surfaces of a vanadium-oxide-based infrared bolometer array. Patterning by metal lift-off relies on protection of the fragile gold black with an evaporated oxide, which preserves gold black's near unity absorption. This patterned gold black also survives the dry-etch removal of the sacrificial polyimide used to fabricate the air-bridge bolometers. Infrared responsivity is substantially improved by the gold black coating without significantly increasing noise. The increase in the time constant caused by the additional mass of gold black is a modest 14%.

  4. Pump dependence of the dynamics of quantum dot based waveguide absorbers

    NASA Astrophysics Data System (ADS)

    Viktorov, Evgeny A.; Erneux, Thomas; Piwonski, Tomasz; Pulka, Jaroslaw; Huyet, Guillaume; Houlihan, John

    2012-06-01

    The nonlinear two stage recovery of quantum dot based reverse-biased waveguide absorbers is investigated experimentally and analytically as a function of the initial ground state occupation probability of the dot. The latter is controlled experimentally by the pump pulse power. The slow stage of the recovery is exponential and its basic timescale is independent of pump power. The fast stage of the recovery is a logistic function which we analyze in detail. The relative strength of slow to fast components is highlighted and the importance of higher order absorption processes at the highest pump level is demonstrated.

  5. Unexpected Performances of Flat Sb2S3-Based Hybrid Extremely Thin Absorber Solar Cells

    NASA Astrophysics Data System (ADS)

    Muto, Takuma; Larramona, Gerardo; Dennler, Gilles

    2013-07-01

    We report unexpected results obtained on hybrid extremely thin absorber (ETA) solar cells based on the structure TiO2/Sb2S3/poly(3-hexylthiophene)/hole conducting layer (HCL). We show that we can maintain a large, state-of-the-art short-circuit current by switching from a three-dimensional to a two-dimensional device, that is, by simplifying drastically the device structure. Moreover, we prove that the HCL plays an important role in the solar cell working mechanism, and influences significantly its open-circuit voltage. We believe that these findings suggest new directions for the optimization of solid-state sensitized solar cells.

  6. A framework for organ dose estimation in x-ray angiography and interventional radiology based on dose-related data in DICOM structured reports

    NASA Astrophysics Data System (ADS)

    Omar, Artur; Bujila, Robert; Fransson, Annette; Andreo, Pedro; Poludniowski, Gavin

    2016-04-01

    Although interventional x-ray angiography (XA) procedures involve relatively high radiation doses that can lead to deterministic tissue reactions in addition to stochastic effects, convenient and accurate estimation of absorbed organ doses has traditionally been out of reach. This has mainly been due to the absence of practical means to access dose-related data that describe the physical context of the numerous exposures during an XA procedure. The present work provides a comprehensive and general framework for the determination of absorbed organ dose, based on non-proprietary access to dose-related data by utilizing widely available DICOM radiation dose structured reports. The framework comprises a straightforward calculation workflow to determine the incident kerma and reconstruction of the geometrical relation between the projected x-ray beam and the patient’s anatomy. The latter is difficult in practice, as the position of the patient on the table top is unknown. A novel patient-specific approach for reconstruction of the patient position on the table is presented. The proposed approach was evaluated for 150 patients by comparing the estimated position of the primary irradiated organs (the target organs) with their position in clinical DICOM images. The approach is shown to locate the target organ position with a mean (max) deviation of 1.3 (4.3), 1.8 (3.6) and 1.4 (2.9) cm for neurovascular, adult and paediatric cardiovascular procedures, respectively. To illustrate the utility of the framework for systematic and automated organ dose estimation in routine clinical practice, a prototype implementation of the framework with Monte Carlo simulations is included.

  7. A framework for organ dose estimation in x-ray angiography and interventional radiology based on dose-related data in DICOM structured reports.

    PubMed

    Omar, Artur; Bujila, Robert; Fransson, Annette; Andreo, Pedro; Poludniowski, Gavin

    2016-04-21

    Although interventional x-ray angiography (XA) procedures involve relatively high radiation doses that can lead to deterministic tissue reactions in addition to stochastic effects, convenient and accurate estimation of absorbed organ doses has traditionally been out of reach. This has mainly been due to the absence of practical means to access dose-related data that describe the physical context of the numerous exposures during an XA procedure. The present work provides a comprehensive and general framework for the determination of absorbed organ dose, based on non-proprietary access to dose-related data by utilizing widely available DICOM radiation dose structured reports. The framework comprises a straightforward calculation workflow to determine the incident kerma and reconstruction of the geometrical relation between the projected x-ray beam and the patient's anatomy. The latter is difficult in practice, as the position of the patient on the table top is unknown. A novel patient-specific approach for reconstruction of the patient position on the table is presented. The proposed approach was evaluated for 150 patients by comparing the estimated position of the primary irradiated organs (the target organs) with their position in clinical DICOM images. The approach is shown to locate the target organ position with a mean (max) deviation of 1.3 (4.3), 1.8 (3.6) and 1.4 (2.9) cm for neurovascular, adult and paediatric cardiovascular procedures, respectively. To illustrate the utility of the framework for systematic and automated organ dose estimation in routine clinical practice, a prototype implementation of the framework with Monte Carlo simulations is included.

  8. KERMA-based radiation dose management system for real-time patient dose measurement

    NASA Astrophysics Data System (ADS)

    Kim, Kyo-Tae; Heo, Ye-Ji; Oh, Kyung-Min; Nam, Sang-Hee; Kang, Sang-Sik; Park, Ji-Koon; Song, Yong-Keun; Park, Sung-Kwang

    2016-07-01

    Because systems that reduce radiation exposure during diagnostic procedures must be developed, significant time and financial resources have been invested in constructing radiation dose management systems. In the present study, the characteristics of an existing ionization-based system were compared to those of a system based on the kinetic energy released per unit mass (KERMA). Furthermore, the feasibility of using the KERMA-based system for patient radiation dose management was verified. The ionization-based system corrected the effects resulting from radiation parameter perturbations in general radiography whereas the KERMA-based system did not. Because of this difference, the KERMA-based radiation dose management system might overestimate the patient's radiation dose due to changes in the radiation conditions. Therefore, if a correction factor describing the correlation between the systems is applied to resolve this issue, then a radiation dose management system can be developed that will enable real-time measurement of the patient's radiation exposure and acquisition of diagnostic images.

  9. Optimal semi-active vibration absorber for harmonic excitation based on controlled semi-active damper

    NASA Astrophysics Data System (ADS)

    Weber, F.

    2014-09-01

    The semi-active vibration absorber (SVA) based on controlled semi-active damper is formulated to realize the behaviour of the passive undamped vibration absorber tuned to the actual harmonic disturbing frequency. It is shown that the controlled stiffness force, which is emulated by the semi-active damper to realize the precise real-time frequency tuning of the SVA, is unpreventably combined with the generation of undesirable damping in the semi-active damper whereby the SVA does not behave as targeted. The semi-active stiffness force is therefore optimized for minimum primary structure response. The results point out that the optimal semi-active stiffness force reduces the undesirable energy dissipation in the SVA at the expenses of slight imprecise frequency tuning. Based on these findings, a real-time applicable suboptimal SVA is formulated that also takes the relative motion constraint of real mass dampers into account. The results demonstrate that the performance of the suboptimal SVA is closer to that of the active solution than that of the passive mass damper.

  10. High power L-band mode-locked fiber laser based on topological insulator saturable absorber.

    PubMed

    Meng, Yichang; Semaan, Georges; Salhi, Mohamed; Niang, Alioune; Guesmi, Khmaies; Luo, Zhi-Chao; Sanchez, Francois

    2015-09-07

    We demonstrate a passive mode-locked Er:Yb doped double-clad fiber laser using a microfiber-based topological insulator (Bi(2)Se(3)) saturable absorber (TISA). By optimizing the cavity loss and output coupling ratio, the mode-locked fiber laser can operate in L-band with high average output power. With the highest pump power of 5 W, 91st harmonic mode locking of soliton bunches with average output power of 308 mW was obtained. This is the first report that the TISA based erbium-doped fiber laser operating above 1.6 μm and is also the highest output power yet reported in TISA based passive mode-locked fiber laser.

  11. Microfiber-based gold nanorods as saturable absorber for femtosecond pulse generation in a fiber laser

    SciTech Connect

    Wang, Xu-De; Luo, Zhi-Chao; Liu, Hao; Liu, Meng; Luo, Ai-Ping Xu, Wen-Cheng

    2014-10-20

    We reported on the femtosecond pulse generation from an erbium-doped fiber (EDF) laser by using microfiber-based gold nanorods (GNRs) as saturable absorber (SA). By virtue of the geometric characteristic of microfiber-based GNRs, the optical damage threshold of GNRs-SA could be greatly enhanced. The microfiber-based GNRs-SA shows a modulation depth of 4.9% and a nonsaturable loss of 21.1%. With the proposed GNRs-SA, the fiber laser emitted a mode-locked pulse train with duration of ∼887 fs. The obtained results demonstrated that the GNRs deposited microfiber could indeed serve as a high-performance SA towards the practical applications in the field of ultrafast photonics.

  12. Biological-Based Modeling of Low Dose Radiation Risks

    SciTech Connect

    Scott, Bobby R., Ph.D.

    2006-11-08

    The objective of this project was to refine a biological-based model (called NEOTRANS2) for low-dose, radiation-induced stochastic effects taking into consideration newly available data, including data on bystander effects (deleterious and protective). The initial refinement led to our NEOTRANS3 model which has undergone further refinement (e.g., to allow for differential DNA repair/apoptosis over different dose regions). The model has been successfully used to explain nonlinear dose-response curves for low-linear-energy-transfer (LET) radiation-induced mutations (in vivo) and neoplastic transformation (in vitro). Relative risk dose-response functions developed for neoplastic transformation have been adapted for application to cancer relative risk evaluation for irradiated humans. Our low-dose research along with that conducted by others collectively demonstrate the following regarding induced protection associated with exposure to low doses of low-LET radiation: (1) protects against cell killing by high-LET alpha particles; (2) protects against spontaneous chromosomal damage; (3) protects against spontaneous mutations and neoplastic transformations; (4) suppresses mutations induced by a large radiation dose even when the low dose is given after the large dose; (5) suppresses spontaneous and alpha-radiation-induced cancers; (6) suppresses metastasis of existing cancer; (7) extends tumor latent period; (8) protects against diseases other than cancer; and (9) extends life expectancy. These forms of radiation-induced protection are called adapted protection as they relate to induced adaptive response. Thus, low doses and dose rates of low-LET radiation generally protect rather than harm us. These findings invalidate the linear not threshold (LNT) hypothesis which is based on the premise that any amount of radiation is harmful irrespective of its type. The hypothesis also implicates a linear dose-response curve for cancer induction that has a positive slope and no

  13. Reflection-type spatial amplitude modulation of visible light based on a sub-wavelength plasmonic absorber.

    PubMed

    Hwang, Chi-Young; Yi, Yoonsik; Choi, Choon-Gi

    2016-03-01

    We present a method for reflection-type spatial amplitude modulation using a sub-wavelength plasmonic absorber structure that can operate in the visible region. We utilize a pixelated array of absorbing elements based on a two-dimensional sub-wavelength metal grating, and the reflectance of each pixel is controlled by simple structural modification. For the purpose of validation, numerical simulations were performed on an amplitude modulation hologram fabricated using our method.

  14. Modes Coupling Analysis of Surface Plasmon Polaritons Based Resonance Manipulation in Infrared Metamaterial Absorber

    PubMed Central

    Zhen, Guoshuai; Zhou, Peiheng; Luo, Xiaojia; Xie, Jianliang; Deng, Longjiang

    2017-01-01

    Surface plasmon polaritons (SPPs) and standing wave modes provide interesting and exotic properties for infrared metamaterial absorbers. Coupling of these modes promises further development in this field but restricted by the complexity of modes analysis. In this work, we investigate the general phenomenon of modes coupling supported by a metal (with grating)-dielectric-metal sandwich structure based on rigorous coupled-wave analysis (RCWA) method and experiment results. Through the analysis of fundamental modes, a new approach based on the boundary conditions is introduced to reveal the coupling mechanism and the corresponding resonance shifting phenomenon with simple but rigorous derivations. The strong coupling between SPPs excited on the dielectric-metal interfaces and rigorous modes of standing waves in the dielectric layer can be manipulated to improve the detection sensitivity of sensors and emissivity efficiency of infrared emitters.

  15. Modes Coupling Analysis of Surface Plasmon Polaritons Based Resonance Manipulation in Infrared Metamaterial Absorber.

    PubMed

    Zhen, Guoshuai; Zhou, Peiheng; Luo, Xiaojia; Xie, Jianliang; Deng, Longjiang

    2017-04-11

    Surface plasmon polaritons (SPPs) and standing wave modes provide interesting and exotic properties for infrared metamaterial absorbers. Coupling of these modes promises further development in this field but restricted by the complexity of modes analysis. In this work, we investigate the general phenomenon of modes coupling supported by a metal (with grating)-dielectric-metal sandwich structure based on rigorous coupled-wave analysis (RCWA) method and experiment results. Through the analysis of fundamental modes, a new approach based on the boundary conditions is introduced to reveal the coupling mechanism and the corresponding resonance shifting phenomenon with simple but rigorous derivations. The strong coupling between SPPs excited on the dielectric-metal interfaces and rigorous modes of standing waves in the dielectric layer can be manipulated to improve the detection sensitivity of sensors and emissivity efficiency of infrared emitters.

  16. Note: Vibration suppression using tunable vibration absorber based on stiffness variable magneto-rheological gel

    NASA Astrophysics Data System (ADS)

    Shin, Beom-Cheol; Yoon, Jung-Hwan; Kim, Young-Keun; Kim, Kyung-Soo

    2015-10-01

    This paper proposes a novel adaptive tunable vibration absorber (TVA) based on a smart material the magnetorheological gel (MRG) to achieve a wide range of tonal vibration suppression on the primary system to protect any connected sensitive device. The vibration suppression performance of the MRG TVA was analyzed by conducting a modal test of the primary system under different magnetic fields. The experiment verified that the proposed MRG TVA can be controlled to produce 379% of stiffness change or 115% of tuning frequency under just 200 mT magnetic field. The proposed MRG TVA was found to possess a wider tuning frequency range than the TVA based on other smart material such as magnetorheological elastomer.

  17. Modeling and characterization of extremely thin absorber (eta) solar cells based on ZnO nanowires.

    PubMed

    Mora-Seró, Iván; Giménez, Sixto; Fabregat-Santiago, Francisco; Azaceta, Eneko; Tena-Zaera, Ramón; Bisquert, Juan

    2011-04-21

    Extremely thin absorber (eta)-solar cells based on ZnO nanowires sensitized with a thin layer of CdSe have been prepared, using CuSCN as hole transporting material. Samples with significantly different photovoltaic performance have been analyzed and a general model of their behavior was obtained. We have used impedance spectroscopy to model the device discriminating the series resistance, the role of the hole conducting material CuSCN, and the interface process. Correlating the impedance analysis with the microstructural properties of the solar cell interfaces, a good description of the solar cell performance is obtained. The use of thick CdSe layers leads to high recombination resistances, increasing the open circuit voltage of the devices. However, there is an increase of the internal recombination in thick light absorbing layers that also inhibit a good penetration of CuSCN, reducing the photocurrent. The model will play an important role on the optimization of these devices. This analysis could have important implications for the modeling and optimization of all-solid devices using a sensitizing configuration.

  18. Measurement-based estimates of direct radiative effects of absorbing aerosols above clouds

    NASA Astrophysics Data System (ADS)

    Feng, Nan; Christopher, Sundar A.

    2015-07-01

    The elevated layers of absorbing smoke aerosols from western African (e.g., Gabon and Congo) biomass burning activities have been frequently observed above low-level stratocumulus clouds off the African coast, which presents an excellent natural laboratory for studying the effects of aerosols above clouds (AAC) on regional energy balance in tropical and subtropical environments. Using spatially and temporally collocated Moderate Resolution Imaging Spectroradiometer, Ozone Monitoring Instrument (OMI), and Clouds and the Earth's Radiant Energy System data sets, the top-of-atmosphere shortwave aerosol direct shortwave radiative effects (ARE) of absorbing aerosols above low-level water clouds in the southeast Atlantic Ocean was examined in this study. The regional averaged instantaneous ARE has been estimated to be 36.7 ± 20.5 Wm-2 (regional mean ± standard deviation) along with a mean positive OMI Aerosol Index at 1.3 in August 2006 based on multisensors measurements. The highest magnitude of instantaneous ARE can even reach 138.2 Wm-2. We assess that the 660 nm cloud optical depth (COD) values of 8-12 is the critical value above (below) which aerosol absorption (scattering) effect dominates and further produces positive (negative) ARE values. The results further show that ARE values are more sensitive to aerosols above lower COD values than cases for higher COD values. This is among the first studies to provide quantitative estimates of shortwave ARE due to AAC events from an observational perspective.

  19. [Experimental study on CO2 absorption by aqueous ammonia-based blended absorbent].

    PubMed

    Xia, Zhi-Xiang; Xiang, Qun-Yang; Zhou, Xu-Ping; Fang, Meng-Xiang

    2014-07-01

    A crucial problem for the promising absorbent aqueous ammonia (NH3) is the low CO2 absorption rate. The mass transfer coefficient (K(G)) of CO2 in aqueous NH3-based absorbents on a wetted wall column facility was investigated. Monoethanolamine (MEA), piperazine (PZ), 1-methyl piperazine (1-MPZ) and 2-methyl piperazine (2-MPZ) were introduced into NH3 solutions as additives, all of which significantly increased the mass transfer coefficient of CO2 in the solutions. With CO2 loading of 0, 0.1, 0.3, 0.5 mol x mol(-1), K(G) of 3 mol x L(-1) NH3 + 0.3 mol x L(-1) PZ blended solution increased by 2, 2.2, 2.2, and 1.9 fold as compared to that of 3 mol x L(-1) NH3. Typically, PZ, the additive with best performance, was chosen for further study. The effects of temperature and PZ concentration on CO2 absorption in PZ solution and the blended NH3/PZ solution. The calculated pseudo first order rate constant [42.7 m3 x (mol x s)(-1)] was analyzed to further elucidate the reaction mechanism in the blended NH3/PZ solution.

  20. Molecular Dynamics of a Water-Absorbent Nanoscale Material Based on Chitosan.

    PubMed

    Borca, Carlos H; Arango, Carlos A

    2016-04-21

    Although hydrogels have been widely investigated for their use in materials science, nanotechnology, and novel pharmaceuticals, mechanistic details explaining their water-absorbent features are not well understood. We performed an all-atom molecular dynamics study of the structural transformation of chitosan nanohydrogels due to water absorption. We analyzed the conformation of dry, nanoscaled chitosan, the structural modifications that emerge during the process of water inclusion, and the dynamics of this biopolymer in the presence of nature's solvent. Two sets of nanoscaled, single-chained chitosan models were simulated: one to study the swelling dependence upon the degree of self-cross-linking and other to observe the response with respect to the degree of protonation. We verified that nanohydrogels keep their ability to absorb water and grow, regardless of their degree of cross-linking. Noteworthy, we found that the swelling behavior of nanoscaled chitosan is pH-dependent, and it is considerably more limited than that of larger scale hydrogels. Thus, our study suggests that properties of nanohydrogels are significantly different from those of larger hydrogels. These findings might be important in the design of novel controlled-release and targeted drug-delivery systems based on chitosan.

  1. APMP supplementary comparison report of absorbed dose rate in tissue for beta radiation (BIPM KCDB: APMP.RI(I)-S2)

    NASA Astrophysics Data System (ADS)

    Kato, M.; Kurosawa, T.; Saito, N.; Kadni, T. B.; Kim, I. J.; Kim, B. C.; Yi, C.-Y.; Pungkun, V.; Chu, C.-H.

    2017-01-01

    The supplementary comparison of absorbed dose rate in tissue for beta radiation (APMP.RI(I)-S2) was performed with five national metrology institutes in 2013 and 2014. Two commercial thin window ionization chambers were used as transfer instruments and circulated among the participants. Two of the NMIs measured the calibration coefficients of the chambers in reference fields produced from Pm-147, Kr-85 and Sr-90/Y-90, while the other three measured those only in Sr-90/Y-90 beta-particle field. The degree of equivalence for the participants was determined and this comparison verifies the calibration capabilities of the participating laboratories. In addition, most of the results of this comparison are consistent with another international comparison (EUROMET.RI(I)-S2) reported before this work. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Capillary scale light emitting diode based multi-reflection absorbance detector.

    PubMed

    Mishra, Santosh K; Dasgupta, Purnendu K

    2007-12-19

    We describe a light emitting diode (LED) based multi-reflection capillary scale absorbance detector based on both square and round capillaries and compare their performance with a conventional single-pass on-tube detector. The optical path length is extended by silver coating, the external surface of the capillary. The reflective geometry has been reported to be less prone to artifacts induced by refractive index changes; we do find this to be true. Although the detection volume/illuminated volume is increased some, a multi-reflection cell based on a 180 microm bore capillary with a approximately 2-cm long illuminated volume shows over a 50-fold gain in signal-to-noise (S/N) compared to a single-pass on-tube configuration with the same capillary. The limit of detection (LOD) is 4.4 fmol (2.6 pg, 1 microL of 22.0 nM injected dye) BTB under pulseless (pneumatic) flow conditions. The cells behave as multipath devices where the effective path lengths are greater at low absorbance values. In our experiments, where non-coherent light is launched through optical fibers that are large compared to capillary bore dimensions, increase in the effective path length of the cell do not occur in a predictable fashion with the angle of incidence of the light beam. Although the effective path length almost linearly increases with increasing distance between the light entry and exit windows, the absolute values of the effective path lengths are always lower than this physical distance, suggesting that after some passage through the solution, light largely travels through or along the glass wall. Square capillaries have better light transmission and offer some performance advantages. Multi-reflection cells can indeed be of value for sensitive detection in microflow systems.

  3. Acoustic perfect absorber based on metasurface with deep sub-wavelength thickness (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Assouar, Badreddine; Li, Yong

    2016-04-01

    The concept of the coiling up space, based on which artificial structures could exhibit extreme acoustic properties, such as high refractive index, double negativity, near-zero index, etc., have been investigated intensively recently due to the fascinating underlying physics and diverse potential applications [1-3]. One of the most important functionality is the ability to shrink bulky structures into deep sub-wavelength scale. It is therefore intuitive to prospect that the concept of coiling up space, if could be extended into the perforated system, will benefit to significantly reduce the total thickness while keeping total absorption. Conventional acoustic absorbers require a structure with a thickness comparable to the working wavelength, resulting major obstacles in real applications in low frequency range. We present a metasurface-based perfect absorber capable of achieving the total absorption of acoustic wave in extremely low frequency region. The metasurface possessing a deep sub-wavelength thickness down to a feature size of ~ lambda/223 is composed of a perforated plate and a coiled coplanar air chamber. Simulations based on fully coupled acoustic with thermodynamic equations and theoretical impedance analysis are utilized to reveal the underlying physics and the acoustic performances, showing an excellent agreement. Our realization should have high impact on amount of applications due to the extremely thin thickness, easy fabrication and high efficiency of the proposed structure. References 1. Z. Liang and J. Li, Phys. Rev. Lett. 108, 114301 (2012). 2. Y. Li, B. Liang, X. Tao, X. F. Zhu, X. Y. Zou, and J. C. Cheng, Appl. Phys. Lett. 101, 233508 (2012). 3. Y. Xie, W. Wang, H. Chen, A. Konneker, B. I. Popa, and S. A. Cummer, Nat. Commun. 5, 5553 (2014).

  4. Development of PET imaging-based dose-painting prescriptions

    NASA Astrophysics Data System (ADS)

    Bowen, Stephen R.

    Historically, prescriptions in radiation therapy are based on physician experience drawn from the results of extensive clinical trials in order to establish standard-of-care guidelines. The doses of radiation are generally uniform across target volumes to reflect a fixed level of local neoplastic disease control of the population mean. However, inter-patient and intra-tumor variation in response to uniform doses can result in diminished tumor control and poor clinical outcome for certain patients. Recent research endeavors are emphasizing the need to individualize prescriptions by incorporating patient-specific biological markers with prognostic and predictive value. Quantitative imaging with positron emission tomography (PET) of tumor glucose metabolism, cell proliferation, and hypoxia has been suggested as a sensitive and specific technique to tailor patient prescriptions in a manner that may significantly improve clinical outcome. The concept of prescribing and delivering non-uniform dose based on molecular imaging, termed dose painting, hinges on the establishment of a dose-response relationship at the image voxel scale that optimizes a particular clinical endpoint. This doctoral thesis presented two methods of defining dose-painting prescriptions based on PET imaging: the first was a heuristic model derivation of hypoxia dose-painting prescriptions in head-and-neck cancer patients; the second was an empirical imaging surrogate endpoint derivation of prescriptions in veterinary sinonasal cancer patients. The clinical implementation of these dose painting prescriptions was investigated, which emphasized treatment planning and delivery solutions. Lastly, a summary and discussion of the future of dose painting to forge links between tumor biology and clinical outcome was presented. The compelling dose painting concept is fast becoming a clinical reality that may positively impact cancer patient lives.

  5. Impact of x-ray dose on track formation and data analysis for CR-39-based proton diagnostics

    SciTech Connect

    Rinderknecht, H. G. Rojas-Herrera, J.; Zylstra, A. B.; Frenje, J. A.; Gatu Johnson, M.; Sio, H.; Sinenian, N.; Rosenberg, M. J.; Li, C. K.; Séguin, F. H.; Petrasso, R. D.; Filkins, T.; Steidle, Jessica A.; Traynor, N.; Freeman, C.; Steidle, Jeffrey A.

    2015-12-15

    The nuclear track detector CR-39 is used extensively for charged particle diagnosis, in particular proton spectroscopy, at inertial confinement fusion facilities. These detectors can absorb x-ray doses from the experiments in the order of 1–100 Gy, the effects of which are not accounted for in the previous detector calibrations. X-ray dose absorbed in the CR-39 has previously been shown to affect the track size of alpha particles in the detector, primarily due to a measured reduction in the material bulk etch rate [Rojas-Herrera et al., Rev. Sci. Instrum. 86, 033501 (2015)]. Similar to the previous findings for alpha particles, protons with energies in the range 0.5–9.1 MeV are shown to produce tracks that are systematically smaller as a function of the absorbed x-ray dose in the CR-39. The reduction of track size due to x-ray dose is found to diminish with time between exposure and etching if the CR-39 is stored at ambient temperature, and complete recovery is observed after two weeks. The impact of this effect on the analysis of data from existing CR-39-based proton diagnostics on OMEGA and the National Ignition Facility is evaluated and best practices are proposed for cases in which the effect of x rays is significant.

  6. Impact of x-ray dose on track formation and data analysis for CR-39-based proton diagnostics

    SciTech Connect

    Rinderknecht, H. G.; Rojas-Herrera, J.; Zylstra, A. B.; Frenje, J. A.; Gatu Johnson, M.; Sio, H.; Sinenian, N.; Rosenberg, M. J.; Li, C. K.; Seguin, F. H.; Petrasso, R. D.; Filkins, T.; Steidle, Jeffrey A.; Steidle, Jessica A.; Traynor, N.; Freeman, C.

    2015-12-23

    The nuclear track detector CR-39 is used extensively for charged particle diagnosis, in particular proton spectroscopy, at inertial confinement fusion facilities. These detectors can absorb x-ray doses from the experiments in the order of 1–100 Gy, the effects of which are not accounted for in the previous detector calibrations. X-ray dose absorbed in the CR-39 has previously been shown to affect the track size of alpha particles in the detector, primarily due to a measured reduction in the material bulk etch rate [Rojas-Herrera et al., Rev. Sci. Instrum. 86, 033501 (2015)]. Similar to the previous findings for alpha particles, protons with energies in the range 0.5–9.1 MeV are shown to produce tracks that are systematically smaller as a function of the absorbed x-ray dose in the CR-39. The reduction of track size due to x-ray dose is found to diminish with time between exposure and etching if the CR-39 is stored at ambient temperature, and complete recovery is observed after two weeks. Lastly, the impact of this effect on the analysis of data from existing CR-39-based proton diagnostics on OMEGA and the National Ignition Facility is evaluated and best practices are proposed for cases in which the effect of x rays is significant.

  7. Impact of x-ray dose on track formation and data analysis for CR-39-based proton diagnostics

    DOE PAGES

    Rinderknecht, H. G.; Rojas-Herrera, J.; Zylstra, A. B.; ...

    2015-12-23

    The nuclear track detector CR-39 is used extensively for charged particle diagnosis, in particular proton spectroscopy, at inertial confinement fusion facilities. These detectors can absorb x-ray doses from the experiments in the order of 1–100 Gy, the effects of which are not accounted for in the previous detector calibrations. X-ray dose absorbed in the CR-39 has previously been shown to affect the track size of alpha particles in the detector, primarily due to a measured reduction in the material bulk etch rate [Rojas-Herrera et al., Rev. Sci. Instrum. 86, 033501 (2015)]. Similar to the previous findings for alpha particles, protonsmore » with energies in the range 0.5–9.1 MeV are shown to produce tracks that are systematically smaller as a function of the absorbed x-ray dose in the CR-39. The reduction of track size due to x-ray dose is found to diminish with time between exposure and etching if the CR-39 is stored at ambient temperature, and complete recovery is observed after two weeks. Lastly, the impact of this effect on the analysis of data from existing CR-39-based proton diagnostics on OMEGA and the National Ignition Facility is evaluated and best practices are proposed for cases in which the effect of x rays is significant.« less

  8. Absorption and scattering properties of carbon nanohorn-based nanofluids for direct sunlight absorbers

    PubMed Central

    2011-01-01

    In the present work, we investigated the scattering and spectrally resolved absorption properties of nanofluids consisting in aqueous and glycol suspensions of single-wall carbon nanohorns. The characteristics of these nanofluids were evaluated in view of their use as sunlight absorber fluids in a solar device. The observed nanoparticle-induced differences in optical properties appeared promising, leading to a considerably higher sunlight absorption with respect to the pure base fluids. Scattered light was found to be not more than about 5% with respect to the total attenuation of light. Both these effects, together with the possible chemical functionalization of carbon nanohorns, make this new kind of nanofluids very interesting for increasing the overall efficiency of the sunlight exploiting device. PACS 78.40.Ri, 78.35.+c, 78.67.Bf, 88.40.fh, 88.40.fr, 81.05.U. PMID:21711795

  9. Split-cross antenna based narrowband mid-infrared absorber for sensing applications

    NASA Astrophysics Data System (ADS)

    Yang, Ao; Yang, Kecheng; Zhou, Lun; Li, Junyu; Tan, Xiaochao; Liu, Huan; Song, Haisheng; Tang, Jiang; Liu, Feng; Yi, Fei

    2017-03-01

    We have investigated numerically a narrowband near unity mid-infrared absorber based on a periodic array of gold split cross antenna backed by a dielectric spacer and a gold backmirror. We systematically studied the spectral dependence on the antenna parameters and explored the optimized parameters for nanofabrication. The optimized structure has a linewidth of 39 nm at 3.17 μm and the peak absorption is 96.5%. This can be explained in terms of surface lattice resonance of the periodic structure. The investigated structure can be devised as a mid-infrared refractive index sensor. Due to the strong near field enhancement and spectral dependence on the surface dielectric conditions, the narrow linewidth arises from the coupled plasmonic-photonic modes in the structure and has potential applications in plasmonic biosensing.

  10. ELECTRON ABSORBED FRACTIONS IN AN IMAGE-BASED MICROSCOPIC SKELETAL DOSIMETRY MODEL OF CHINESE ADULT MALE.

    PubMed

    Gao, Shenshen; Ren, Li; Qiu, Rui; Wu, Zhen; Li, Chunyan; Li, Junli

    2017-01-10

    Based on the Chinese reference adult male voxel model, a set of microscopic skeletal models of Chinese adult male is constructed through the processes of computed tomography (CT) imaging, bone coring, micro-CT imaging, image segmentation, merging into macroscopic bone model and implementation in Geant4. At the step of image segmentation, a new bone endosteum (BE) segmentation method is realized by sampling. The set of model contains 32 spongiosa samples with voxel size of 19 μm cubes. The microscopic spongiosa bone data for Chinese adult male are provided. Electron absorbed fractions in red bone marrow (RBM) and BE are calculated. Source tissues include the bone marrow (red and yellow), trabecular bone (surfaces and volumes) and cortical bone (surfaces and volumes). Target tissues include RBM and BE. Electron energies range from 10 keV to 10 MeV. Additionally, comparison of the result with other investigations is provided.

  11. A subwavelength resolution microwave/6.3 GHz camera based on a metamaterial absorber

    PubMed Central

    Xie, Yunsong; Fan, Xin; Chen, Yunpeng; Wilson, Jeffrey D.; Simons, Rainee N.; Xiao, John Q.

    2017-01-01

    The design, fabrication and characterization of a novel metamaterial absorber based camera with subwavelength spatial resolution are investigated. The proposed camera is featured with simple and lightweight design, easy portability, low cost, high resolution and sensitivity, and minimal image interference or distortion to the original field distribution. The imaging capability of the proposed camera was characterized in both near field and far field ranges. The experimental and simulated near field images both reveal that the camera produces qualitatively accurate images with negligible distortion to the original field distribution. The far field demonstration was done by coupling the designed camera with a microwave convex lens. The far field results further demonstrate that the camera can capture quantitatively accurate electromagnetic wave distribution in the diffraction limit. The proposed camera can be used in application such as non-destructive image and beam direction tracer. PMID:28071734

  12. A universal electromagnetic energy conversion adapter based on a metamaterial absorber

    NASA Astrophysics Data System (ADS)

    Xie, Yunsong; Fan, Xin; Wilson, Jeffrey D.; Simons, Rainee N.; Chen, Yunpeng; Xiao, John Q.

    2014-09-01

    On the heels of metamaterial absorbers (MAs) which produce near perfect electromagnetic (EM) absorption and emission, we propose a universal electromagnetic energy conversion adapter (UEECA) based on MA. By choosing the appropriate energy converting sensors, the UEECA is able to achieve near 100% signal transfer ratio between EM energy and various forms of energy such as thermal, DC electric, or higher harmonic EM energy. The inherited subwavelength dimension and the EM field intensity enhancement can further empower UEECA in many critical applications such as energy harvesting, photoconductive antennas, and nonlinear optics. The principle of UEECA is understood with a transmission line model, which further provides a design strategy that can incorporate a variety of energy conversion devices. The concept is experimentally validated at a microwave frequency with a signal transfer ratio of 96% by choosing an RF diode as the energy converting sensor.

  13. Grating-type mid-infrared light absorber based on silicon carbide material.

    PubMed

    Xue, Wenrui; Chen, Xi; Peng, Yanling; Yang, Rongcao

    2016-10-03

    A kind of grating-type mid-infrared light absorber based on silicon carbide (SiC) material is designed and its absorption properties are studied using the finite-difference frequency-domain (FDFD) method. The results show that, its absorption mechanism is the excitation of surface plasmon and magnetic polariton as well as the loss of materials. Due to the optical characteristics of the SiC material in the mid-infrared band and the truncated pyramid structure in the grating, in the range of 10.5-12.5μm and 0-80°, absorptivity of higher than 80% can be obtained with optimized structural parameters. Among six structural parameters, the layer number of the composite layers has a relatively great influence on the absorption properties, while the thickness of the dielectric layer has less influence on the absorption properties.

  14. A universal electromagnetic energy conversion adapter based on a metamaterial absorber

    PubMed Central

    Xie, Yunsong; Fan, Xin; Wilson, Jeffrey D.; Simons, Rainee N.; Chen, Yunpeng; Xiao, John Q.

    2014-01-01

    On the heels of metamaterial absorbers (MAs) which produce near perfect electromagnetic (EM) absorption and emission, we propose a universal electromagnetic energy conversion adapter (UEECA) based on MA. By choosing the appropriate energy converting sensors, the UEECA is able to achieve near 100% signal transfer ratio between EM energy and various forms of energy such as thermal, DC electric, or higher harmonic EM energy. The inherited subwavelength dimension and the EM field intensity enhancement can further empower UEECA in many critical applications such as energy harvesting, photoconductive antennas, and nonlinear optics. The principle of UEECA is understood with a transmission line model, which further provides a design strategy that can incorporate a variety of energy conversion devices. The concept is experimentally validated at a microwave frequency with a signal transfer ratio of 96% by choosing an RF diode as the energy converting sensor. PMID:25200005

  15. Low-frequency metamaterial absorber with small-size unit cell based on corrugated surface

    NASA Astrophysics Data System (ADS)

    Wang, Nan; Dong, Xiaochun; Zhou, Weicheng; He, Chuanwang; Jiang, Wei; Hu, Song

    2016-02-01

    In this paper, we report the design, analysis, and simulation of the low-frequency perfect metamaterial absorber (MMA) based on corrugated surface, which has very small unit-cell size. The proposed MMA consist of a regular square-array and a metallic background plane, separated by a corrugated surface with periodic square-pillar-array. Through the optimized design, the ratios between lattice constant and resonance wavelength for nearly-perfect and high absorption MMA are close to 1/15 and 1/21, respectively. To explain the absorption mechanism of suggested structures, the surface current and electromagnetic field distributions are given. Moreover, the absorption peaks remain high with large angles of incidence for both transverse electric and transverse magnetic polarizations, which provide more efficient absorptions for oblique incident electromagnetic wave.

  16. Phase based stiffness tuning algorithm for a magnetorheological elastomer dynamic vibration absorber

    NASA Astrophysics Data System (ADS)

    Liao, Guojiang; Gong, Xinglong; Xuan, Shouhu

    2014-01-01

    This paper presents a phase based stiffness tuning algorithm to overcome the uncertainty of the relation between the magnetic current and the natural frequency for magnetorheological elastomer (MRE) dynamic vibration absorbers (DVA) caused by the nonlinearity of the MRE. The phase difference of the relative acceleration of the DVA mass and the absolute acceleration of the primary system was used to check whether the natural frequency of the DVA is adjusted to the excitation frequency. The magnetic current was controlled by the phase difference, which made the proposed algorithm not rely on the model of the MRE DVA. Both the simulation and the experiment demonstrate that the proposed algorithm is efficient for MRE DVA in rapidly tracking the excitation frequency.

  17. A subwavelength resolution microwave/6.3 GHz camera based on a metamaterial absorber

    NASA Astrophysics Data System (ADS)

    Xie, Yunsong; Fan, Xin; Chen, Yunpeng; Wilson, Jeffrey D.; Simons, Rainee N.; Xiao, John Q.

    2017-01-01

    The design, fabrication and characterization of a novel metamaterial absorber based camera with subwavelength spatial resolution are investigated. The proposed camera is featured with simple and lightweight design, easy portability, low cost, high resolution and sensitivity, and minimal image interference or distortion to the original field distribution. The imaging capability of the proposed camera was characterized in both near field and far field ranges. The experimental and simulated near field images both reveal that the camera produces qualitatively accurate images with negligible distortion to the original field distribution. The far field demonstration was done by coupling the designed camera with a microwave convex lens. The far field results further demonstrate that the camera can capture quantitatively accurate electromagnetic wave distribution in the diffraction limit. The proposed camera can be used in application such as non-destructive image and beam direction tracer.

  18. A universal electromagnetic energy conversion adapter based on a metamaterial absorber.

    PubMed

    Xie, Yunsong; Fan, Xin; Wilson, Jeffrey D; Simons, Rainee N; Chen, Yunpeng; Xiao, John Q

    2014-09-09

    On the heels of metamaterial absorbers (MAs) which produce near perfect electromagnetic (EM) absorption and emission, we propose a universal electromagnetic energy conversion adapter (UEECA) based on MA. By choosing the appropriate energy converting sensors, the UEECA is able to achieve near 100% signal transfer ratio between EM energy and various forms of energy such as thermal, DC electric, or higher harmonic EM energy. The inherited subwavelength dimension and the EM field intensity enhancement can further empower UEECA in many critical applications such as energy harvesting, photoconductive antennas, and nonlinear optics. The principle of UEECA is understood with a transmission line model, which further provides a design strategy that can incorporate a variety of energy conversion devices. The concept is experimentally validated at a microwave frequency with a signal transfer ratio of 96% by choosing an RF diode as the energy converting sensor.

  19. Few-layer black phosphorus based saturable absorber mirror for pulsed solid-state lasers.

    PubMed

    Ma, Jie; Lu, Shunbin; Guo, Zhinan; Xu, Xiaodong; Zhang, Han; Tang, Dingyuan; Fan, Dianyuan

    2015-08-24

    We experimentally demonstrated that few-layer black phosphorus (BP) could be used as an optical modulator for solid-state lasers to generate short laser pulses. The BP flakes were fabricated by the liquid phase exfoliation method and drop-casted on a high-reflection mirror to form a BP-based saturable absorber mirror (BP-SAM). Stable Q-switched pulses with a pulse width of 620 ns at the wavelength of 1046 nm were obtained in a Yb:CaYAlO(4) (Yb:CYA) laser with the BP-SAM. The generated pulse train has a repetition rate of 113.6 kHz and an average output power of 37 mW. Our results show that the BP-SAMs could have excellent prospective for ultrafast photonics applications.

  20. A subwavelength resolution microwave/6.3 GHz camera based on a metamaterial absorber.

    PubMed

    Xie, Yunsong; Fan, Xin; Chen, Yunpeng; Wilson, Jeffrey D; Simons, Rainee N; Xiao, John Q

    2017-01-10

    The design, fabrication and characterization of a novel metamaterial absorber based camera with subwavelength spatial resolution are investigated. The proposed camera is featured with simple and lightweight design, easy portability, low cost, high resolution and sensitivity, and minimal image interference or distortion to the original field distribution. The imaging capability of the proposed camera was characterized in both near field and far field ranges. The experimental and simulated near field images both reveal that the camera produces qualitatively accurate images with negligible distortion to the original field distribution. The far field demonstration was done by coupling the designed camera with a microwave convex lens. The far field results further demonstrate that the camera can capture quantitatively accurate electromagnetic wave distribution in the diffraction limit. The proposed camera can be used in application such as non-destructive image and beam direction tracer.

  1. Ultrathin low-frequency sound absorbing panels based on coplanar spiral tubes or coplanar Helmholtz resonators

    NASA Astrophysics Data System (ADS)

    Cai, Xiaobing; Guo, Qiuquan; Hu, Gengkai; Yang, Jun

    2014-09-01

    Performance of classic sound absorbing materials strictly depends on their thickness, with a minimum of one-quarter wavelength to reach full sound absorption. In this paper, we report ultrathin sound absorbing panels that completely absorb sound energy with a thickness around one percent of wavelength. The strategy is to bend and coil up quarter-wavelength sound damping tubes into 2D coplanar ones, and embed them into a matrix to form sound absorbing panel. Samples have been designed and fabricated by 3D printing. Efficacies of sound absorption by these panels were validated through good agreement between theoretical analysis and experimental measurements.

  2. Novel quad-band terahertz metamaterial absorber based on single pattern U-shaped resonator

    NASA Astrophysics Data System (ADS)

    Wang, Ben-Xin; Wang, Gui-Zhen

    2017-03-01

    A novel quad-band terahertz metamaterial absorber using four different modes of single pattern resonator is demonstrated. Four obvious frequencies with near-perfect absorption are realized. Near-field distributions of the four modes are provided to reveal the physical picture of the multiple-band absorption. Unlike most previous quad-band absorbers that typically require four or more patterns, the designed absorber has only one resonant structure, which is simpler than previous works. The presented quad-band absorber has potential applications in biological sensing, medical imaging, and material detection.

  3. Recent developments of smart electromagnetic absorbers based polymer-composites at gigahertz frequencies

    NASA Astrophysics Data System (ADS)

    Idris, Fadzidah Mohd.; Hashim, Mansor; Abbas, Zulkifly; Ismail, Ismayadi; Nazlan, Rodziah; Ibrahim, Idza Riati

    2016-05-01

    The rapid increase in electromagnetic interference has received a serious attention from researchers who responded by producing a variety of radar absorbing materials especially at high gigahertz frequencies. Ongoing investigation is being carried out in order to find the best absorbing materials which can fulfill the requirements for smart absorbing materials which are lightweight, broad bandwidth absorption, stronger absorption etc. Thus, to improve the absorbing capability, several important parameters need to be taken into consideration such as filler type, loading level, type of polymer matrix, physical thickness, grain sizes, layers and bandwidth. Therefore, this article introduces the electromagnetic wave absorption mechanisms and then reveals and reviews those parameters that enhance the absorption performance.

  4. TESS-based dose-response using pediatric clonidine exposures

    SciTech Connect

    Benson, Blaine E. . E-mail: jebenson@salud.unm.edu; Spyker, Daniel A.; Troutman, William G.; Watson, William A. . E-mail: http://www.aapcc.org/

    2006-06-01

    Objective: The toxic and lethal doses of clonidine in children are unclear. This study was designed to determine whether data from the American Association of Poison Control Centers Toxic Exposure Surveillance System (TESS) could be utilized to determine a dose-response relationship for pediatric clonidine exposure. Methods: 3458 single-substance clonidine exposures in children <6 years of age reported to TESS from January 2000 through December 2003 were examined. Dose ingested, age, and medical outcome were available for 1550 cases. Respiratory arrest cases (n = 8) were classified as the most severe of the medical outcome categories (Arrest, Major, Moderate, Mild, and No effect). Exposures reported as a 'taste or lick' (n = 51) were included as a dose of 1/10 of the dosage form involved. Dose ranged from 0.4 to 1980 (median 13) {mu}g/kg. Weight was imputed based on a quadratic estimate of weight for age. Dose certainty was coded as exact (26% of cases) or not exact (74%). Medical outcome (response) was examined via logistic regression using SAS JMP (release 5.1). Results: The logistic model describing medical outcome (P < 0.0001) included Log dose/kg (P 0.0000) and Certainty (P = 0.045). Conclusion: TESS data can provide the basis for a statistically sound description of dose-response for pediatric clonidine poisoning exposures.

  5. Helicopter rotor lag damping augmentation based on a radial absorber and Coriolis coupling

    NASA Astrophysics Data System (ADS)

    Byers, Lynn Karen

    A radial vibration absorber is proposed to augment rotor lag damping. Modeled as a discrete mass restrained by a damped spring and moving along the spanwise direction within the rotor blade, it introduces damping into the lag mode of the blade through strong Coriolis coupling. A two-degree-of-freedom model is developed and used to examine the effectiveness of the radial absorber in transferring damping to the rotor lag mode. Results demonstrate that it is possible to introduce a significant amount of damping in the lag mode with a relatively small absorber mass, and the corresponding amplitudes of 1/rev periodic motions are not excessively large. The lag mode damping and 1/rev motions are also compared with the results achieved for an embedded chordwise inertial damper. A classical six-degree-of-freedom aeromechanical stability analysis is augmented with two absorber cyclic degrees of freedom in the nonrotating frame to examine the effect of the radial absorber on aeromechanical stability characteristics. These results indicate that ground resonance instability is eliminated for the range of absorber parameters considered, and in most cases, the stability margins are significant. A rotor blade with a discrete radial vibration absorber is also analyzed to examine the effect of the absorber on rotor blade and hub loads. The rotor blade is modeled as an elastic beam undergoing flap and lag bending, with the absorber modeled as a discrete mass restrained by a damped spring, moving in the spanwise direction within the rotor blade. Results indicate that the addition of the absorber does not detrimentally affect the blade spanwise and root loads, as well as steady and vibratory hub loads. Finally, device concepts and implementation possibilities are considered for the embedded radial vibration absorber.

  6. Development of FeCoB/Graphene Oxide based microwave absorbing materials for X-Band region

    NASA Astrophysics Data System (ADS)

    Das, Sukanta; Chandra Nayak, Ganesh; Sahu, S. K.; Oraon, Ramesh

    2015-06-01

    This work explored the microwave absorption capability of Graphene Oxide and Graphene Oxide coated with FeCoB for stealth technology. Epoxy based microwave absorbing materials were prepared with 30% loading of Graphene Oxide, FeCoB alloy and Graphene Oxide coated with FeCoB. Graphene Oxide and FeCoB were synthesized by Hummer's and Co-precipitation methods, respectively. The filler particles were characterized by FESEM, XRD and Vibrating Sample Magnetometer techniques. Permittivity, permeability and reflection loss values of the composite absorbers were measured with vector network analyzer which showed a reflection loss value of -7.86 dB, at 10.72 GHz, for single layered Graphene Oxide/Epoxy based microwave absorbers which can be correlated to the absorption of about 83.97% of the incident microwave energy. Reflection loss value of FeCoB/Epoxy based microwave absorber showed -13.30 dB at 11.67 GHz, which corresponded to maximum absorption of 93.8%. However, reflection loss values of Graphene Oxide coated with FeCoB/Epoxy based single-layer absorber increased to -22.24 dB at 12.4 GHz which corresponds to an absorption of 99% of the incident microwave energy.

  7. Low temperature y-ray spectrometers based on bulk superconducting and dielectric absorber crystals

    SciTech Connect

    Netel, Harrie

    1999-11-19

    Many areas of research rely on the detection of radiation, in the form of single photons or particles. By measuring the photons or particles coming from an object a lot can be learned about the object under study. In some cases there is a simple need to know the number of photons coming from the source. In cases like this a simple counter, like a Geiger-Mueller survey meter, will suffice. In other cases one want to know the spectral distribution of the photons coming from the source. In cases like that a spectrometer is needed that can distinguish between photons with different energies, like a diffraction or transmission grating. The work presented in this thesis focused on the development of a new generation broad band spectrometer that has a high energy resolving power, combined with a high absorption efficiency for photon energies above 10 keV and up to 500 keV. The spectrometers we are developing are based on low-temperature sensors, like superconducting tunnel junctions or transition edge sensors, that are coupled to bulk absorber crystals. We use the low-temperature sensors because they can offer a significant improvement in energy resolving power, compared to conventional spectrometers. We couple the low-temperature sensors to bulk absorber crystals to increase the absorption efficiency. In this chapter I introduce different types of radiation detectors and spectrometers and areas where they are being used. I also discuss the history and motivation of low-temperature spectrometers and show some of the impressive results that have been achieved in this field over the last few years. Finally I discuss the outline of this thesis.

  8. Gigahertz range electromagnetic wave absorbers made of amorphous-carbon-based magnetic nanocomposites

    NASA Astrophysics Data System (ADS)

    Liu, Jiu Rong; Itoh, Masahiro; Horikawa, Takashi; Machida, Ken-Ichi; Sugimoto, Satoshi; Maeda, Toru

    2005-09-01

    Nanocomposite magnetic materials α-Fe/C(a), Fe2B/C(a), and Fe1.4Co0.6B/C(a) were prepared by mechanically grinding α-Fe, Fe2B, or Fe1.4Co0.6B with amorphous carbon [C(a)] powders. Complex permittivity, permeability, and electromagnetic wave absorption properties of resin compacts containing 40-vol % composite powders of α-Fe/C(a), Fe2B/C(a), and Fe1.4Co0.6B/C(a) were characterized according to a conventional reflection/transmission technique. The real part (ɛr') and imaginary part (Vr'') of the relative permittivity are low and almost independent of frequency between 0.05 and 40 GHz. The Imaginary part (μr'') of the relative permeability exhibited wide peaks in the 1-9-GHz range for α-Fe/C(a), in the 2-18-GHz range for Fe2B/C(a), and in the 18-40-GHz range for Fe1.4Co0.6B/C(a) owing to their different magnetocrystalline anisotropy field (HA) values. Consequently, the resin compacts of 40-vol % α-Fe/C(a), Fe2B/C(a), and Fe1.4Co0.6B/C(a) powders provided good electromagnetic (em) wave absorption performances (reflection loss<-20 dB) in ranges of 4.3-8.2 GHz (G band), 7.5-16.0 GHz (X band), and 26.5-40 GHz (Q band) over absorber thicknesses of 1.8-3.3, 1.2-2.2, and 0.63-0.82 mm, respectively. Our experimental results demonstrate that the amorphous-carbon-based magnetic nanocomposites are promising for the application to produce thin and light EM wave absorbers.

  9. Metamaterial-based high efficiency absorbers for high temperature solar applications (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Yellowhair, Julius E.; Kwon, Hoyeong; Alù, Andrea; Jarecki, Robert L.; Shinde, Subhash L.

    2016-09-01

    Operation of concentrated solar power receivers at higher temperatures (<700°C) would enable supercritical carbon dioxide (sCO2) power cycles for improved power cycle efficiencies (<50%) and cost-effective solar thermal power. Unfortunately, radiative losses at higher temperatures in conventional receivers can negatively impact the system efficiency gains. One approach to improve receiver thermal efficiency is to utilize selective coatings that enhance absorption across the visible solar spectrum while minimizing emission in the infrared to reduce radiative losses. Existing coatings, however, tend to degrade rapidly at elevated temperatures. In this paper, we report on the initial designs, fabrication, and characterization of spectrally selective metamaterial-based absorbers for high-temperature, high-thermal flux environments important for solarized sCO2 power cycles. Metamaterials are structured media whose optical properties are determined by sub-wavelength structural features instead of bulk material properties, providing unique solutions by decoupling the optical absorption spectrum from thermal stability requirements. The key enabling innovative concept proposed is the use of structured surfaces with spectral responses that can be tailored to optimize the absorption and retention of solar energy for a given temperature range. In this initial study we use Tungsten for its stability in expected harsh environments, compatibility with microfabrication techniques, and required optical performance. Our goal is to tailor the optical properties for high (near unity) absorptivity across the majority of the solar spectrum and over a broad range of incidence angles, and at the same time achieve negligible absorptivity in the near infrared to optimize the energy absorbed and retained. To this goal, we apply the recently developed concept of plasmonic Brewster angle to suitably designed nanostructured Tungsten surfaces. We predict that this will improve the receiver

  10. Poly(dimethylsiloxane) photonic microbioreactors based on segmented waveguides for local absorbance measurement.

    PubMed

    Demming, Stefanie; Vila-Planas, Jordi; Aliasghar Zadeh, Sobehir; Edlich, Astrid; Franco-Lara, Ezequiel; Radespiel, Rolf; Büttgenbach, Stephanus; Llobera, Andreu

    2011-02-01

    We present the development of microbioreactors (MBRs) based on poly(dimethylsiloxane) (PDMS) segmented waveguides (SWG) for local absorbance measurements. Two different MBRs were studied, either using symmetric or asymmetric SWG (being defined as MBR-S and MBR-A, respectively). Their optical and fluidic performances were numerically analyzed, showing robustness from an optical point of view and distinct fluid flow profile. The optical characterization was done in two steps. Initially, the experimental limit of detection (LOD) and the sensitivity were determined for two different analytes (fluorescein and methylorange). With both systems, a similar limit of detection for both analytes was obtained, being in the micromolar level. Their sensitivities were 20.2±0.3 (×10⁻³) A.U./μM and 5.5±0.2 (×10⁻³) A.U./μM for fluorescein and methylorange, respectively. Once validated its applicability for local absorbance measurements, a continuous cultivation of Saccharomyces cerevisiae was done to test the viability of the proposed systems for photonic MBRs. Concretely, the cell growth was locally monitored inside the MBR during 33 h. Spectral analysis showed that the determination of the culture parameters were wavelength dependant, with a growth rate of 0.39±0.02 h⁻¹ and a doubling time of 1.65±0.09 h at an optimal wavelength of 469.9±0.3 nm. Besides the easy and monolithic integration of the SWG into poly(dimethylsiloxane) microfluidic systems, the results presented here are very promising for the application in any disposable photonic lab-on-a-chip systems used for online analysis or photonic MBRs.

  11. Synthesis and characterization of a novel super-absorbent based on wheat straw.

    PubMed

    Ma, Zuohao; Li, Qian; Yue, Qinyan; Gao, Baoyu; Xu, Xing; Zhong, Qianqian

    2011-02-01

    In order to develop an eco-friendly polymer, a novel super-absorbent polymer was prepared by graft copolymerization of acrylic acid (AA), acrylic amide (AM) and dimethyl diallyl ammonium chloride (DMDAAC) onto the pretreatment wheat straw (PTWS). The molecular structure of the super-absorbent was confirmed by FTIR. The factors that can influence absorbencies of the super-absorbent resin (SAR) were investigated, such as weight ratio between the monomers, the ratio of PTWS to monomers, the amount of initiator and cross-linker, temperature reaction time and neutralization degree of AA. The SAR has the water absorbency of 133.76 g/g in distilled water and 33.83 g/g in 0.9 wt.% NaCl solution.

  12. Metamaterial slab-based super-absorbers and perfect nanodetectors for single dipole sources.

    PubMed

    Guo, Guang-Yu; Klimov, Vasily; Sun, Shulin; Zheng, Wei-Jin

    2013-05-06

    We propose to use double negative (DNG) metamaterial slabs to build effective super-absorbers and perfect nanodetectors for single divergent sources. We demonstrate by numerical simulations that an absorbing nanoparticle properly placed inside a DNG slab back-covered with a perfect electric conductor or perfect magnetic conductor mirror can absorb up to 100% radiation energy of a single dipole source placed outside the slab. Furthermore, we also show that even the simple DNG slab without any absorbing nanoparticle could be used as a perfect absorber for both plane and divergent beams. The proposed systems may focus the radiation in nanoscale and thus have applications in optical nanodevices for a variety of different purposes.

  13. A water calorimeter for on-site absorbed dose to water calibrations in 60Co and MV-photon beams including MRI incorporated treatment equipment

    NASA Astrophysics Data System (ADS)

    de Prez, Leon; de Pooter, Jacco; Jansen, Bartel; Aalbers, Tony

    2016-07-01

    In reference dosimetry the aim is to establish the absorbed dose to water, D w, under reference conditions. However, existing dosimetry protocols are not always applicable for rapidly emerging new treatment modalities. For primary standard dosimetry laboratories it is generally not feasible to acquire such modalities. Therefore it is strongly desired that D w measurements with primary standards can be performed on-site in clinical beams for the new treatment modalities in order to characterize and calibrate detectors. To serve this need, VSL has developed a new transportable water calorimeter serving as a primary D w standard for 60Co and MV-photons including MRI incorporated treatment equipment. Special attention was paid to its operation in different beam geometries and beam modalities including the application in magnetic fields. The new calorimeter was validated in the VSL 60Co beam and on-site in clinical MV-photon beams. Excellent agreement of 0.1% was achieved with previous 60Co field calibrations, i.e. well within the uncertainty of the previous calorimeter, and with measurements performed in horizontal and vertical MV-photon beams. k Q factors, determined for two PTW 30013 ionization chambers, agreed very well with available literature data. The relative combined standard uncertainty (k  =  1) for D w measurements in 60Co and MV-photons is 0.37%. Calibrations are carried out with a standard uncertainty of 0.42% and k Q -factors are determined with a relative standard uncertainty of 0.40%.

  14. Theoretical investigation of all-metal-based mushroom plasmonic metamaterial absorbers at infrared wavelengths

    NASA Astrophysics Data System (ADS)

    Ogawa, Shinpei; Fujisawa, Daisuke; Kimata, Masafumi

    2015-12-01

    High-performance wavelength-selective infrared (IR) sensors require small pixel structures, a low-thermal mass, and operation in the middle-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) regions for multicolor IR imaging. All-metal-based mushroom plasmonic metamaterial absorbers (MPMAs) were investigated theoretically and were designed to enhance the performance of wavelength-selective uncooled IR sensors. All components of the MPMAs are based on thin layers of metals such as Au without oxide insulators for increased absorption. The absorption properties of the MPMAs were investigated by rigorous coupled-wave analysis. Strong wavelength-selective absorption is realized over a wide range of MWIR and LWIR wavelengths by the plasmonic resonance of the micropatch and the narrow-gap resonance, without disturbance from the intrinsic absorption of oxide insulators. The absorption wavelength is defined mainly by the micropatch size and is longer than its period. The metal post width has less impact on the absorption properties and can maintain single-mode operation. Through-holes can be formed on the plate area to reduce the thermal mass. A small pixel size with reduced thermal mass and wideband single-mode operation can be realized using all-metal-based MPMAs.

  15. Study on separation of platinum group metals from high level liquid waste using macroporous (MOTDGA-TOA)/SiO{sub 2}-P silica-based absorbent

    SciTech Connect

    Ito, Tatsuya; Kim, Seong-Yun; Xu, Yuanlai; Hitomi, Keitaro; Ishii, Keizo; Nagaishi, Ryuji; Kimura, Takaumi

    2013-07-01

    The recovery of platinum group metals (PGMs) from high level liquid waste (HLLW) by macroporous silica-based adsorbent, (MOTDGA-TOA)/SiO{sub 2}-P has been developed by impregnating two extractants of N,N'-dimethyl-N,N'-di-n-octyl-thio-diglycolamide (MOTDGA) and tri-n-octylamine (TOA) into a silica/polymer composite support (SiO{sub 2}-P). The adsorption of Ru(III), Rh(III) and Pd(II) have been investigated in simulated HLLW by batch method. The adsorbent has shown good uptake property for Pd(II). In addition, the combined use of MOTDGA and TOA improved the adsorption of Ru(III) and Rh(III) better than the individual use of them. The usability of adsorbent in radiation fields was further confirmed by irradiation experiments. The adsorbent remained to have the uptake capability for PGMs over the absorbed dose of 100 kGy, corresponding with one really adsorbed by the adsorbent, and showed good retention capability for Pd(II) even at the absorbed dose of 800 kGy. The chromatographic separation of metal ions was demonstrated with the adsorbent packed column, there is no influence of Re(VII) (instead of Tc) on the excellent separation behavior of Pd(II). (authors)

  16. Electrospun novel super-absorbent based on polysaccharide-polyvinyl alcohol-montmorillonite clay nanocomposites.

    PubMed

    Islam, Md Shahidul; Rahaman, Md Saifur; Yeum, Jeong Hyun

    2015-01-22

    A novel super-absorbent material was fabricated by electrospinning the natural polysaccharide pullulan (PULL) with polyvinyl alcohol (PVA) and montmorillonite (MMT) clay to form nonwoven webs, which were then heat treated. Transmission electron microscopy (TEM) micrographs, X-ray diffraction (XRD) patterns, and Fourier transform infrared (FTIR) analysis of the novel super-absorbent nanofibers suggest the coexistence of PULL, PVA, and MMT through the exfoliation of MMT layers in the super-absorbent nanofiber composite. The heat-treated PULL/PVA/MMT webs loaded with 5 wt% MMT electrospun nanofibers exhibited a water absorbency of 143.42 g g(-1) in distilled water and a water absorbency of 39.75 g g(-1) in a 0.9 wt% NaCl solution. Under extremely dry conditions, the PULL/PVA/MMT webs exhibited the ability to retain 43% distilled water and 38% saline water after being exposed to the atmosphere for one week. The heat treatment improved the crystallinity of the electrospun PULL/PVA/MMT super-absorbent webs and thus made the webs highly stable in aqueous environments. Overall, the addition of MMT resulted in improved thermal stability and mechanical properties and increased the water absorbency of the PULL/PVA/MMT composite.

  17. Novel approach for designing a thin and broadband microwave absorber in Ku band based on substituted M-hexaferrites

    NASA Astrophysics Data System (ADS)

    Afghahi, Seyyed Salman Seyyed; Jafarian, Mojtaba; Atassi, Yomen

    2016-12-01

    The design of novel microwave absorbers in the Ku band is still challenging. The aim of this work is to report the design of a new Ku absorber based on the combination of three M-hexaferrites with the formula of BaX0.3Y0.3Cr0.3Fe11.1O19 (XY=Co2+Zr4+, Zn2+Ti4+, Mn2+Ce4+), 15 wt% of each in epoxy matrix. The results indicate the formation of a broadband absorber with a reflection loss (RL) lower than -10 dB over the whole bandwidth 13.75-18 GHz. It has three matching frequencies (14.2, 15.3 and 16.8 GHz) with RL (-29.2, -21.5 and -24.7 dB, respectively) at a matching thickness of only 2.5 mm. This is to be compared with the RL of the absorbers based on 45 wt% of each ferrite alone in epoxy matrix are (-15, -28.8 and -20 dB, respectively) at matching frequency of (14.15, 13.55 and 16.5 GHz) and a matching thickness of 4 mm. This favorable performance resulting from combining the three ferrites within the absorber may be attributed to the enhanced exchange coupling interactions between the three powders of distinct magnetic characteristics.

  18. A promising lightweight multicomponent microwave absorber based on doped barium hexaferrite/calcium titanate/multiwalled carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Afghahi, Seyyed Salman Seyyed; Jafarian, Mojtaba; Atassi, Yomen

    2016-07-01

    We present the design of a microwave absorber in the X band based on ternary nanocomposite of doped barium hexaferrite (Ba-M)/calcium titanate (CTO)/multiwall carbon nanotubes (MWCNTs) in epoxy matrix. The hydrothermal method has been used to synthesize Ba-M and CTO nanopowder. The phase identification has been investigated using XRD patterns. Scanning electron microscope, transmission electron microscope, vibrating sample magnetometer, and vector network analyzer are used to analyze the morphology of the different components and the magnetic, electromagnetic, and microwave absorption properties of the final composite absorbers, respectively. As far as we know, the design of this type of multicomponent microwave absorber has not been investigated before. The results reveal that the combination of these three components with their different loss mechanisms has a synergistic effect that enhances the attenuation properties of the final composite. The absorber of only 2.5-mm thickness and 35 wt% of loading ratio exhibits a minimum reflection loss of -43 dB at 10.2 GHz with a bandwidth of 3.6 GHz, while the corresponding absorber based on pure (Ba-M) shows a minimum reflection loss of -34 dB at 9.8 GHz with a bandwidth of 0.256 GHz and a thickness of 4 mm.

  19. Gamma Knife radiosurgery with CT image-based dose calculation.

    PubMed

    Xu, Andy Yuanguang; Bhatnagar, Jagdish; Bednarz, Greg; Niranjan, Ajay; Kondziolka, Douglas; Flickinger, John; Lunsford, L Dade; Huq, M Saiful

    2015-11-01

    The Leksell GammaPlan software version 10 introduces a CT image-based segmentation tool for automatic skull definition and a convolution dose calculation algorithm for tissue inhomogeneity correction. The purpose of this work was to evaluate the impact of these new approaches on routine clinical Gamma Knife treatment planning. Sixty-five patients who underwent CT image-guided Gamma Knife radiosurgeries at the University of Pittsburgh Medical Center in recent years were retrospectively investigated. The diagnoses for these cases include trigeminal neuralgia, meningioma, acoustic neuroma, AVM, glioma, and benign and metastatic brain tumors. Dose calculations were performed for each patient with the same dose prescriptions and the same shot arrangements using three different approaches: 1) TMR 10 dose calculation with imaging skull definition; 2) convolution dose calculation with imaging skull definition; 3) TMR 10 dose calculation with conventional measurement-based skull definition. For each treatment matrix, the total treatment time, the target coverage index, the selectivity index, the gradient index, and a set of dose statistics parameters were compared between the three calculations. The dose statistics parameters investigated include the prescription isodose volume, the 12 Gy isodose volume, the minimum, maximum and mean doses on the treatment targets, and the critical structures under consideration. The difference between the convolution and the TMR 10 dose calculations for the 104 treatment matrices were found to vary with the patient anatomy, location of the treatment shots, and the tissue inhomogeneities around the treatment target. An average difference of 8.4% was observed for the total treatment times between the convolution and the TMR algorithms. The maximum differences in the treatment times, the prescription isodose volumes, the 12 Gy isodose volumes, the target coverage indices, the selectivity indices, and the gradient indices from the convolution

  20. Gamma Knife radiosurgery with CT image-based dose calculation.

    PubMed

    Xu, Andy Yuanguang; Bhatnagar, Jagdish; Bednarz, Greg; Niranjan, Ajay; Kondziolka, Douglas; Flickinger, John; Lunsford, L Dade; Huq, M Saiful

    2015-11-08

    The Leksell GammaPlan software version 10 introduces a CT image-based segmentation tool for automatic skull definition and a convolution dose calculation algorithm for tissue inhomogeneity correction. The purpose of this work was to evaluate the impact of these new approaches on routine clinical Gamma Knife treatment planning. Sixty-five patients who underwent CT image-guided Gamma Knife radiosurgeries at the University of Pittsburgh Medical Center in recent years were retrospectively investigated. The diagnoses for these cases include trigeminal neuralgia, meningioma, acoustic neuroma, AVM, glioma, and benign and metastatic brain tumors. Dose calculations were performed for each patient with the same dose prescriptions and the same shot arrangements using three different approaches: 1) TMR 10 dose calculation with imaging skull definition; 2) convolution dose calculation with imaging skull definition; 3) TMR 10 dose calculation with conventional measurement-based skull definition. For each treatment matrix, the total treatment time, the target coverage index, the selectivity index, the gradient index, and a set of dose statistics parameters were compared between the three calculations. The dose statistics parameters investigated include the prescription isodose volume, the 12 Gy isodose volume, the minimum, maximum and mean doses on the treatment targets, and the critical structures under consideration. The difference between the convolution and the TMR 10 dose calculations for the 104 treatment matrices were found to vary with the patient anatomy, location of the treatment shots, and the tissue inhomogeneities around the treatment target. An average difference of 8.4% was observed for the total treatment times between the convolution and the TMR algorithms. The maximum differences in the treatment times, the prescription isodose volumes, the 12 Gy isodose volumes, the target coverage indices, the selectivity indices, and the gradient indices from the convolution

  1. Flow-induced corrosion behavior of absorbable magnesium-based stents.

    PubMed

    Wang, Juan; Giridharan, Venkataraman; Shanov, Vesselin; Xu, Zhigang; Collins, Boyce; White, Leon; Jang, Yongseok; Sankar, Jagannathan; Huang, Nan; Yun, Yeoheung

    2014-12-01

    The aim of this work was to study corrosion behavior of magnesium (Mg) alloys (MgZnCa plates and AZ31 stents) under varied fluid flow conditions representative of the vascular environment. Experiments revealed that fluid hydrodynamics, fluid flow velocity and shear stress play essential roles in the corrosion behavior of absorbable magnesium-based stent devices. Flow-induced shear stress (FISS) accelerates the overall corrosion (including localized, uniform, pitting and erosion corrosions) due to the increased mass transfer and mechanical force. FISS increased the average uniform corrosion rate, the localized corrosion coverage ratios and depths and the removal rate of corrosion products inside the corrosion pits. For MgZnCa plates, an increase of FISS results in an increased pitting factor but saturates at an FISS of ∼0.15Pa. For AZ31 stents, the volume loss ratio (31%) at 0.056Pa was nearly twice that (17%) at 0Pa before and after corrosion. Flow direction has a significant impact on corrosion behavior as more severe pitting and erosion corrosion was observed on the back ends of the MgZnCa plates, and the corrosion product layer facing the flow direction peeled off from the AZ31 stent struts. This study demonstrates that flow-induced corrosion needs be understood so that Mg-based stents in vascular environments can be effectively designed.

  2. Graphene-based Recyclable Photo-Absorbers for High-Efficiency Seawater Desalination.

    PubMed

    Wang, Xiangqing; Ou, Gang; Wang, Ning; Wu, Hui

    2016-04-13

    Today's scientific advances in water desalination dramatically increase our ability to transform seawater into fresh water. As an important source of renewable energy, solar power holds great potential to drive the desalination of seawater. Previously, solar assisted evaporation systems usually relied on highly concentrated sunlight or were not suitable to treat seawater or wastewater, severely limiting the large scale application of solar evaporation technology. Thus, a new strategy is urgently required in order to overcome these problems. In this study, we developed a solar thermal evaporation system based on reduced graphene oxide (rGO) decorated with magnetic nanoparticles (MNPs). Because this material can absorb over 95% of sunlight, we achieved high evaporation efficiency up to 70% under only 1 kW m(-2) irradiation. Moreover, it could be separated from seawater under the action of magnetic force by decorated with MNPs. Thus, this system provides an advantage of recyclability, which can significantly reduce the material consumptions. Additionally, by using photoabsorbing bulk or layer materials, the deposition of solutes offen occurs in pores of materials during seawater desalination, leading to the decrease of efficiency. However, this problem can be easily solved by using MNPs, which suggests this system can be used in not only pure water system but also high-salinity wastewater system. This study shows good prospects of graphene-based materials for seawater desalination and high-salinity wastewater treatment.

  3. Design of multiple-layer microwave absorbing structure based on rice husk and carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Seng, Lee Yeng; Wee, F. H.; Rahim, H. A.; AbdulMalek, MohamedFareq; You, Y. K.; Liyana, Z.; Ezanuddin, A. A. M.

    2017-01-01

    This paper presents a multiple-layered microwave absorber using rice husk and carbon nanotube composite. The dielectric properties of each layer composite were measured and analysed. The different layer of microwave absorber enables to control the microwave absorption performance. The microwave absorption performances are demonstrated through measurements of reflectivity over the frequency range 2-18 GHz. An improvement of microwave absorption <-20 dB is observed with respect to a high lossy composite placed at bottom layer of multiple layers. Reflectivity evaluations indicate that the composites display a great potential application as wideband electromagnetic wave absorbers.

  4. Polarization-independent broadband absorber based on pyramidal metal-dielectric grating structure

    NASA Astrophysics Data System (ADS)

    Wu, Jun

    2016-12-01

    An infrared broadband polarization-independent metamaterial absorber is designed and investigated. It consists of a pyramidal metal-dielectric multilayered rectangle grating structure. The absorber exhibits near-unit absorption at multiple adjacent wavelengths overlapping with each other, which results in a high absorption over a wide wavelength range. The absorbance at normal incidence is higher than 90% in a wavelength range of 2321 nm-4631 nm, and the broadband absorption performance can be maintained over a large incident angle range. Furthermore, the mechanism of such broadband absorption are investigated by illustrating the electric field distributions for TE polarization and magnetic field distributions for TM polarization at the resonant wavelengths. It is believed that the conclusions can be applied for developing polarization-independent broadband absorber.

  5. On the frequency-selective features of gold nanorods-based columnar thin film metamaterial absorber

    NASA Astrophysics Data System (ADS)

    Ghasemi, Masih; Choudhury, P. K.; Baqir, M. A.; Mohamed, M. A.; Zain, A. R. M.; Majlis, B. Y.

    2016-09-01

    Metamaterials have been of great interest owing to multifarious technological applications. Among various applications of scientific need, the perfect absorber kind of property of metamaterials remains prudent. Within the context, this investigation describes the filtering/absorber applications of metasurfaces comprised of columnar nanorods of gold having circular and elliptical cross-sections. The spectral features of such absorbers are investigated in terms of absorptivity in the visible to infrared (IR) regimes. The results indicate of almost perfect absorption corresponding to certain wavelengths in the IR span. Also, multiple absorption peaks would determine the filtering characteristics of the structures under consideration. It has been found that the absorber having circular nanorods exhibits better performance than the one with elliptical nanorods in terms of the magnitude/smoothness of absorption peaks in the entire electromagnetic spectral region of interest; the case of elliptical nanorods makes the absorption spectra to yield too much of flickers in the IR range of wavelength.

  6. Perfect absorbers based on metal-insulator-metal structures in the visible region: a simple approach for practical applications

    NASA Astrophysics Data System (ADS)

    Kenanakis, G.; Mavidis, Ch. P.; Vasilaki, E.; Katsarakis, N.; Kafesaki, M.; Economou, E. N.; Soukoulis, C. M.

    2017-01-01

    Perfect absorbers based on metal-insulator-metal (MIM) structures are proposed and demonstrated, both theoretically and experimentally, in the visible region. The proposed structures may possess either sharp or broadband absorption peaks, by simply choosing a single layer of the proposed MIM structure or building several layers of them, while no nanofabrication steps or structure patterning are required, and thus can be easily made to cover a large area. The highly efficient absorption of the MIM structures is maintained for both TE and TM incident polarization, and for angles of incidence up to 75°, indicating that the proposed perfect absorbers can be potentially deployed for solar cells applications and optics.

  7. Ultra-thin Low-Frequency Broadband Microwave Absorber Based on Magnetic Medium and Metamaterial

    NASA Astrophysics Data System (ADS)

    Cheng, Yongzhi; He, Bo; Zhao, Jingcheng; Gong, Rongzhou

    2017-02-01

    An ultra-thin low-frequency broadband microwave absorber (MWA) based on a magnetic rubber plate (MRP) and cross-shaped structure (CSS) metamaterial (MM) was presented numerically and experimentally. The designed composite MWA is consisted of the MRP, CSS resonator, dielectric substrate and metallic background plane. The low-frequency absorption can be easily adjusted by tuning the geometric parameter of the CSS MM and the thickness of MPR. A bandwidth (i.e. the reflectance is below -10 dB) from 2.5 GHz to 5 GHz can be achieved with the total thickness of about 2 mm in experiments. The broadband absorption is attributed to the overlap of two resonant absorption peaks originated from MRP and CSS MM, respectively. More importantly, the thickness of the composite WMA is much thinner ( λ/40; λ is the operation center frequency), which could operate well at wide incidence angles for both transverse electric and transverse magnetic waves. Thus, it can be expected that our design will be applicable in the area of eliminating microwave energy and electromagnetic stealth.

  8. Tunable polarization sensitive absorber made of graphene-based hyperbolic metamaterials

    NASA Astrophysics Data System (ADS)

    Madani, Amir; Babaei, Maryam

    2017-02-01

    Theoretically, the absorption properties of a hyperbolic metamaterial (HMM) slab constructed from graphene-dielectric multilayers are investigated using the transfer matrix method. The effective medium approximation reveals that the graphene-based HMM slab is an anisotropic and homogeneous medium. It is shown that the absorption of the slab depend on the polarization and incidence angle due to the strong anisotropy of the HMMs. The results revealed that the complete absorption is only possible for the TM-polarized waves in a broad region of wavelength. It is found that the region of total absorption can be controlled and tuned using some controlling parameters such as incidence angle, the orientation of the optical axis of the HMM medium and the chemical potential of the graphene monolayers. Finally, the intensity distribution of a TM-polarized Gaussian beam is simulated which verifies the strong absorption of the waves inside the HMM slab. This absorber may have potential applications in the design of tunable filters, polarizers, detectors, photovoltaic devices and so on.

  9. Information Security Risk Assessment of Smart Grid Based on Absorbing Markov Chain and SPA

    NASA Astrophysics Data System (ADS)

    Jianye, Zhang; Qinshun, Zeng; Yiyang, Song; Cunbin, Li

    2014-12-01

    To assess and prevent the smart grid information security risks more effectively, this paper provides risk index quantitative calculation method based on absorbing Markov chain to overcome the deficiencies that links between system components were not taken into consideration and studies mostly were limited to static evaluation. The method avoids the shortcomings of traditional Expert Score with significant subjective factors and also considers the links between information system components, which make the risk index system closer to the reality. Then, a smart grid information security risk assessment model on the basis of set pair analysis improved by Markov chain was established. Using the identity, discrepancy, and contradiction of connection degree to dynamically reflect the trend of smart grid information security risk and combining with the Markov chain to calculate connection degree of the next period, the model implemented the smart grid information security risk assessment comprehensively and dynamically. Finally, this paper proves that the established model is scientific, effective, and feasible to dynamically evaluate the smart grid information security risks.

  10. Soft and broadband infrared metamaterial absorber based on gold nanorod/liquid crystal hybrid with tunable total absorption.

    PubMed

    Su, Zhaoxian; Yin, Jianbo; Zhao, Xiaopeng

    2015-11-18

    We design a soft infrared metamaterial absorber based on gold nanorods dispersed in liquid crystal (LC) placed on a gold film and theoretically investigate its total absorption character. Because the nanorods align with the LC molecule, the gold nanorods/LC hybrid exhibits different permittivity as a function of tilt angle of LC. At a certain tilt angle, the absorber shows an omnidirectional total absorption effect. By changing the tilt angle of LC by an external electric field, the total absorption character can be adjusted. The total absorption character also depends on the concentration, geometric dimension of nanorods, and defect of nanorod arrangement in LC. When the LC contains different size of gold nanorods, a broadband absorption can be easily realized. The characteristics including flexibility, omnidirectional, broadband and tunability make the infrared metamaterial absorber possess potential use in smart metamaterial devices.

  11. Fluence-to-absorbed dose conversion coefficients for use in radiological protection of embryo and foetus against external exposure to electrons from 10 MeV TO 10 GeV.

    PubMed

    Chen, Jing

    2008-04-01

    Electrons as primary and more often as secondary radiation exist commonly in the environment and workplaces. No conversion coefficients are yet available, in the literature, for use in radiological protection of embryo and foetus against external exposure to electrons. This study uses mathematical models developed by the Radiation Protection Bureau, Health Canada, for the embryo of 8 wk and for the foetus of 3, 6, and 9 mo. Monte Carlo code MCNPX is used to determine mean absorbed doses to the embryo and foetus when the mother is exposed to external electron fields. Monoenergetic electrons ranging from 10 MeV to 10 GeV were considered. The irradiation geometries include antero-posterior (AP), postero-anterior (PA), lateral (LAT), rotational (ROT), isotropic (ISO), and top-down (TOP). At each of these irradiation geometries, absorbed doses to the foetal brain and body were calculated for the embryo of 8 wk and the foetus of 3, 6, and 9 mo. Electron fluence-to-absorbed dose conversion coefficients were derived for the four prenatal ages.

  12. Advanced neutron absorber materials

    DOEpatents

    Branagan, Daniel J.; Smolik, Galen R.

    2000-01-01

    A neutron absorbing material and method utilizing rare earth elements such as gadolinium, europium and samarium to form metallic glasses and/or noble base nano/microcrystalline materials, the neutron absorbing material having a combination of superior neutron capture cross sections coupled with enhanced resistance to corrosion, oxidation and leaching.

  13. Nanoparticle-based cancer treatment: can delivered dose and biological dose be reliably modeled and quantified?

    NASA Astrophysics Data System (ADS)

    Hoopes, P. Jack; Petryk, Alicia A.; Giustini, Andrew J.; Stigliano, Robert V.; D'Angelo, Robert N.; Tate, Jennifer A.; Cassim, Shiraz M.; Foreman, Allan; Bischof, John C.; Pearce, John A.; Ryan, Thomas

    2011-03-01

    Essential developments in the reliable and effective use of heat in medicine include: 1) the ability to model energy deposition and the resulting thermal distribution and tissue damage (Arrhenius models) over time in 3D, 2) the development of non-invasive thermometry and imaging for tissue damage monitoring, and 3) the development of clinically relevant algorithms for accurate prediction of the biological effect resulting from a delivered thermal dose in mammalian cells, tissues, and organs. The accuracy and usefulness of this information varies with the type of thermal treatment, sensitivity and accuracy of tissue assessment, and volume, shape, and heterogeneity of the tumor target and normal tissue. That said, without the development of an algorithm that has allowed the comparison and prediction of the effects of hyperthermia in a wide variety of tumor and normal tissues and settings (cumulative equivalent minutes/ CEM), hyperthermia would never have achieved clinical relevance. A new hyperthermia technology, magnetic nanoparticle-based hyperthermia (mNPH), has distinct advantages over the previous techniques: the ability to target the heat to individual cancer cells (with a nontoxic nanoparticle), and to excite the nanoparticles noninvasively with a noninjurious magnetic field, thus sparing associated normal cells and greatly improving the therapeutic ratio. As such, this modality has great potential as a primary and adjuvant cancer therapy. Although the targeted and safe nature of the noninvasive external activation (hysteretic heating) are a tremendous asset, the large number of therapy based variables and the lack of an accurate and useful method for predicting, assessing and quantifying mNP dose and treatment effect is a major obstacle to moving the technology into routine clinical practice. Among other parameters, mNPH will require the accurate determination of specific nanoparticle heating capability, the total nanoparticle content and biodistribution in

  14. Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water at 10 g cm-2 of the NPL, United Kingdom and the BIPM in accelerator photon beams

    NASA Astrophysics Data System (ADS)

    Picard, S.; Burns, D. T.; Roger, P.; Duane, S.; Bass, G. A.; Manning, J. W.; Shipley, D. R.

    2015-01-01

    A comparison of the dosimetry for accelerator photon beams was carried out between the National Physical Laboratory (NPL) and the Bureau International des Poids et Mesures (BIPM) from 23 September to 7 October 2014. The comparison was based on the determination of absorbed dose to water at 10 g cm-2 for three radiation qualities at the NPL. The results, reported as ratios of the NPL and the BIPM evaluations (and with the combined standard uncertainties given in parentheses), are 1.0000(62) at 6 MV, 0.9999(70) at 10 MV and 0.9993(80) at 25 MV. This result is the seventh in the on-going BIPM.RI(I)-K6 series of comparisons. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  15. Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water at 5 g cm-2 and 7 g cm-2 of the NPL, United Kingdom and the BIPM in accelerator photon beams

    NASA Astrophysics Data System (ADS)

    Picard, S.; Burns, D. T.; Roger, P.; Duane, S.; Bass, G. A.; Manning, J. W.; Shipley, D. R.

    2015-01-01

    A comparison of the dosimetry for accelerator photon beams was carried out between the National Physical Laboratory (NPL) and the Bureau International des Poids et Mesures (BIPM) in two periods from September to November 2013. The comparison was based on the determination of absorbed dose to water for three radiation qualities at the NPL. The results, reported as ratios of the NPL and the BIPM evaluations (and with the combined standard uncertainties given in parentheses), are 0.9973(62) at 6 MV, 0.9995(66) at 10 MV and 0.9957(81) at 25 MV. This result is the sixth in the on-going BIPM.RI(I)-K6 series of comparisons. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. Key comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water at 10 g cm-2 of the NMIJ, Japan and the BIPM in accelerator photon beams

    NASA Astrophysics Data System (ADS)

    Picard, S.; Burns, D. T.; Roger, P.; Shimizu, M.; Morishita, Y.; Kato, M.; Tanaka, T.; Kurosawa, T.; Saito, N.

    2016-01-01

    A comparison of the dosimetry for accelerator photon beams was carried out between the National Metrology Institute of Japan (NMIJ) and the Bureau International des Poids et Mesures (BIPM) from 9 to 23 April 2015. The comparison was based on the determination of absorbed dose to water at 10 g cm-2 for three radiation qualities at the NMIJ. The results, reported as ratios of the NMIJ and the BIPM evaluations (and with the combined standard uncertainties given in parentheses), are 0.9966 (47) at 6 MV, 0.9965 (60) at 10 MV and 0.9953 (50) at 15 MV. This result is the eighth in the on-going BIPM.RI(I)-K6 series of comparisons. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  17. Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method.

    PubMed

    Larson, David B

    2014-10-01

    The principle of ALARA (dose as low as reasonably achievable) calls for dose optimization rather than dose reduction, per se. Optimization of CT radiation dose is accomplished by producing images of acceptable diagnostic image quality using the lowest dose method available. Because it is image quality that constrains the dose, CT dose optimization is primarily a problem of image quality rather than radiation dose. Therefore, the primary focus in CT radiation dose optimization should be on image quality. However, no reliable direct measure of image quality has been developed for routine clinical practice. Until such measures become available, size-specific dose estimates (SSDE) can be used as a reasonable image-quality estimate. The SSDE method of radiation dose optimization for CT abdomen and pelvis consists of plotting SSDE for a sample of examinations as a function of patient size, establishing an SSDE threshold curve based on radiologists' assessment of image quality, and modifying protocols to consistently produce doses that are slightly above the threshold SSDE curve. Challenges in operationalizing CT radiation dose optimization include data gathering and monitoring, managing the complexities of the numerous protocols, scanners and operators, and understanding the relationship of the automated tube current modulation (ATCM) parameters to image quality. Because CT manufacturers currently maintain their ATCM algorithms as secret for proprietary reasons, prospective modeling of SSDE for patient populations is not possible without reverse engineering the ATCM algorithm and, hence, optimization by this method requires a trial-and-error approach.

  18. Short-pulsed laser transport in absorbing and scattering media: time-based versus frequency-based approaches

    NASA Astrophysics Data System (ADS)

    Francoeur, Mathieu; Rousse, Daniel R.

    2007-09-01

    Optical tomography (OT) is a promising non-intrusive characterization technique of absorbing and scattering media that uses transmitted and/or reflected signals of samples irradiated with visible or near-infrared light. The quality of OT techniques is directly related to the accuracy of their forward models due to the use of inversion algorithms. In this paper, forward models for transient OT approaches are investigated. The system under study involves a one-dimensional absorbing and scattering medium illuminated by a short laser pulse; this problem is solved using a discrete ordinates-finite volume (DO-FV) method in both time and frequency domain. Previous works have shown that time-domain approaches coupled with first order spatial interpolation schemes cannot represent the physics of the problem adequately as transmitted fluxes emerge before the minimal physical time required to leave the medium. In this work, the Van Leer and Superbee flux limiters, combined with the second order Lax-Wendroff scheme, are used in an attempt to prevent this. Results show that despite significant improvement, flux limiters fail to completely eliminate the physically unrealistic behaviour. On the other hand, results for transmittance obtained from the frequency-based method are accurate, without physically unrealistic behaviours at early time periods. The frequency-dependent approach is however computationally expensive, since it requires approximately five times more computational time than its temporal counterpart when used as a forward model for transient OT. On the other hand, the great advantages of the frequency-based approach is that limited windows of temporal signals can be calculated efficiently (in transient OT), and it can also be used as a forward model for steady-state, frequency-based and transient OT techniques.

  19. Metasurface perfect absorber based on guided resonance of a photonic hypercrystal

    NASA Astrophysics Data System (ADS)

    Chang, You-Chia; Kildishev, Alexander V.; Narimanov, Evgenii E.; Norris, Theodore B.

    2016-10-01

    By exploiting the guided resonance of a photonic hypercrystal—a periodic structure that combines the properties of hyperbolic materials and photonic crystals—we numerically demonstrate a perfect absorber consisting of a photonic hypercrystal slab, a dielectric spacer, and a back reflector. The guided resonance of the photonic hypercrystal slab creates a field enhancement and confinement within a deep subwavelength thickness; therefore, the ultrathin photonic hypercrystal slab serves as a two-dimensional resonator that can be treated accurately as a metasurface. We show that the perfect absorber is equivalent to a metasurface Salisbury screen, where the metasurface formed by the photonic hypercrystal slab provides the appropriate electric sheet conductivity required for critical coupling. We also present examples of combining the perfect absorber with graphene to make optical modulators and to improve the absorption in graphene photodetectors.

  20. Multi-band microwave metamaterial absorber based on coplanar Jerusalem crosses

    NASA Astrophysics Data System (ADS)

    Wang, Guo-Dong; Liu, Ming-Hai; Hu, Xi-Wei; Kong, Ling-Hua; Cheng, Li-Li; Chen, Zhao-Quan

    2014-01-01

    The influence of the gap on the absorption performance of the conventional split ring resonator (SRR) absorber is investigated at microwave frequencies. Our simulated results reveal that the geometry of the square SRR can be equivalent to a Jerusalem cross (JC) resonator and its corresponding metamaterial absorber (MA) is changed to a JC absorber. The JC MA exhibits an experimental absorption peak of 99.1% at 8.72 GHz, which shows an excellent agreement with our simulated results. By simply assembling several JCs with slightly different geometric parameters next to each other into a unit cell, a perfect multi-band absorption can be effectively obtained. The experimental results show that the MA has four distinct and strong absorption peaks at 8.32 GHz, 9.8 GHz, 11.52 GHz and 13.24 GHz. Finally, the multi-reflection interference theory is introduced to interpret the absorption mechanism.

  1. Magnetically manipulable perfect unidirectional absorber based on nonreciprocal magnetic surface plasmon

    NASA Astrophysics Data System (ADS)

    Yu, Jingjing; Chen, Huajin; Wu, Yongbin; Liu, Shiyang

    2012-11-01

    We demonstrate a design of a perfect unidirectional absorber by constructing a magnetic metamaterial (MM) made of an array of ferrite rods. Near the magnetic surface plasmon (MSP) resonance an incident transverse magnetic (TM) Gaussian beam can be absorbed completely at a particular direction, while at the symmetrically opposite direction an obvious reflected beam is observed. This unidirectionality originates from the time reversal symmetry (TRS)-breaking nature of the MM, which can also be shown numerically by comparing the scattering amplitude of the partial waves in two opposite directions. In addition, the unidirectionality can be reversed by reversing the magnetization of the ferrite rods. The working frequency can be controlled as well by tuning the external magnetic field (EMF). Another merit of this absorber is the robustness against position and size disorders of the ferrite rods.

  2. The absorbance spectrum and photosensitivity of a new synthetic "visual pigment" based on 4-hydroxyretinal.

    PubMed

    Kito, Y; Partridge, J C; Seidou, M; Narita, K; Hamanaka, T; Michinomae, M; Sekiya, N; Yoshihara, K

    1992-01-01

    The firefly squid, Watasenia scintillans, is the only animal known to possess a visual pigment in which the chromophore is 4-hydroxyretinal. This paper describes the absorbance spectrum and some properties of a synthetic "A4" visual pigment generated from bovine opsin and 4-hydroxyretinal. The absorbance spectrum of this pigment is compared with (a) bovine rhodopsin and (b) a rhodopsin template with the same lambda max as the synthetic visual pigment. The A4 pigment is shown to have an absorbance spectrum that is almost identical to that of a rhodopsin template. It is also shown that the photosensitivity and thermal stability of the A4 pigment, dispersed in detergent micelles, is essentially similar to that of rhodopsin.

  3. Independently tunable dual-band perfect absorber based on graphene at mid-infrared frequencies

    DOE PAGES

    Zhang, Yuping; Li, Tongtong; Chen, Qi; ...

    2015-12-22

    We design a dual-band absorber formed by combining two cross-shaped metallic resonators of different sizes within a super-unit-cell arranged in mirror symmetry. Simulations indicate that absorption efficiencies greater than 99% can be achieved at two different frequencies under normal incidence. We also employ a design scheme with graphene integration, which allows independent tuning of individual absorption frequencies by electrostatically changing the Fermi energy of the graphene layer. High absorbance is maintained over a wide incident angle range up to 50 degrees for both TE and TM polarizations. Thus, it enables a promising way to design electrically tunable absorbers, which maymore » contribute toward the realization of frequency selective detectors for sensing applications.« less

  4. Independently tunable dual-band perfect absorber based on graphene at mid-infrared frequencies

    SciTech Connect

    Zhang, Yuping; Li, Tongtong; Chen, Qi; Zhang, Huiyun; O’Hara, John F.; Abele, Ethan; Taylor, Antoinette J.; Chen, Hou-Tong; Azad, Abul K.

    2015-12-22

    We design a dual-band absorber formed by combining two cross-shaped metallic resonators of different sizes within a super-unit-cell arranged in mirror symmetry. Simulations indicate that absorption efficiencies greater than 99% can be achieved at two different frequencies under normal incidence. We also employ a design scheme with graphene integration, which allows independent tuning of individual absorption frequencies by electrostatically changing the Fermi energy of the graphene layer. High absorbance is maintained over a wide incident angle range up to 50 degrees for both TE and TM polarizations. Thus, it enables a promising way to design electrically tunable absorbers, which may contribute toward the realization of frequency selective detectors for sensing applications.

  5. Investigation of packaging systems for shelled walnuts based on oxygen absorbers.

    PubMed

    Jensen, Pernille N; Sørensen, Gitte; Brockhoff, Per; Bertelsen, Grete

    2003-08-13

    Storage of nuts at a high oxygen concentration results in rancid nuts whereas storage at a low oxygen concentration results in fine-tasting nuts. During a 13 month experiment, packaging of walnuts with an oxygen absorber was compared to packaging in nitrogen or atmospheric air. At the same time, the effects of oxygen permeability of the packaging material and storage temperature (11 and 21 degrees C) were investigated by determination of hexanal and rancid taste of the walnuts. The optimal storage condition for walnuts is at 11 degrees C or lower, eventually combined with an oxygen absorber. However, without chilled storage and use of an oxygen absorber, it is possible to obtain an acceptable quality of walnuts with a packaging material having a very low oxygen permeability (e.g., laminate with EVOH) combined with nitrogen flushing. The results also revealed that the development of hexanal during time can be described by a second-order polynomial regression model.

  6. Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-Man anatomical model

    NASA Astrophysics Data System (ADS)

    Bozkurt, A.; Chao, T. C.; Xu, X. G.; Bozkurt, A.; Chao, T. C.

    2000-10-01

    A new set of fluence-to-absorbed dose and fluence-to-effective dose conversion coefficients have been calculated for neutrons below 20 MeV using a whole-body anatomical model, VIP-Man, developed from the high-resolution transverse colour photographic images of the National Library of Medicine's Visible Human Project®. Organ dose calculations were performed using the Monte Carlo code MCNP for 20 monoenergetic neutron beams between 1×10-9 MeV and 20 MeV under six different irradiation geometries: anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic. The absorbed dose for 24 major organs and effective dose results based on the realistic VIP-Man are presented and compared with those based on the simplified MIRD-based phantoms reported in the literature. Effective doses from VIP-Man are not significantly different from earlier results for neutrons in the energy range studied. There are, however, remarkable deviations in organ doses due to the anatomical differences between the image-based and the earlier mathematical models.

  7. Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-man anatomical model.

    PubMed

    Bozkurt, A; Chao, T C; Xu, X G

    2000-10-01

    A new set of fluence-to-absorbed dose and fluence-to-effective dose conversion coefficients have been calculated for neutrons below 20 MeV using a whole-body anatomical model, VIP-Man, developed from the high-resolution transverse colour photographic images of the National Library of Medicine's Visible Human Project. Organ dose calculations were performed using the Monte Carlo code MCNP for 20 monoenergetic neutron beams between 1 x 10(-9) MeV and 20 MeV under six different irradiation geometries: anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic. The absorbed dose for 24 major organs and effective dose results based on the realistic VIP-Man are presented and compared with those based on the simplified MIRD-based phantoms reported in the literature. Effective doses from VIP-Man are not significantly different from earlier results for neutrons in the energy range studied. There are, however, remarkable deviations in organ doses due to the anatomical differences between the image-based and the earlier mathematical models.

  8. Thermal and optical analysis of selective absorber coatings based on soot for applications in solar cookers

    NASA Astrophysics Data System (ADS)

    Servín, H.; Peña, M.; Sobral, H.; González, M.

    2017-01-01

    The thermal and optical properties of selective absorber coatings of a solar cooker have been investigated. Coatings have been prepared using soot from pine resin, wood stove and sugarcane, previously separated by size. Results show that the cooking power and the overall efficiency of these pots are higher than others painted with black primer. Besides, by using an integrating sphere, the diffuse reflectance of absorbers has been obtained. Lower values of the reflectance have been measured for the pots covered with soot, showing a high correlation with the results achieved from the thermal tests, considering the measurement errors.

  9. Analysis of ultra-broadband metamaterial absorber based on simplified multi-reflection interference theory

    NASA Astrophysics Data System (ADS)

    Huang, Xiaojun; He, Xiaoling; Guo, Linyan; Yi, Yuanyuan; Xiao, Boxun; Yang, Helin

    2015-05-01

    The simplified multireflection interference theory is proposed to analyze the physical insight quantitatively of the ultra-broadband metamaterial absorber (MMA) loading lumped resisters in which the resonant layer, including lumped resisters and the substrate, are equivalent to a homogeneous and isotropic effective medium. The simulated full width at half maximum (FWHM) absorption bandwidths is approximately 11.2 GHz with relative FWHM absorption bandwidths of 116.7% for a normal incidence electromagnetic wave. Microwave experiments are performed and measured results are in good agreement with the numerical results. The absorbance of the proposed MMA calculated by the simplified multi-reflection interference theory coincides well with simulated and measured results.

  10. Gamma regularization based reconstruction for low dose CT.

    PubMed

    Zhang, Junfeng; Chen, Yang; Hu, Yining; Luo, Limin; Shu, Huazhong; Li, Bicao; Liu, Jin; Coatrieux, Jean-Louis

    2015-09-07

    Reducing the radiation in computerized tomography is today a major concern in radiology. Low dose computerized tomography (LDCT) offers a sound way to deal with this problem. However, more severe noise in the reconstructed CT images is observed under low dose scan protocols (e.g. lowered tube current or voltage values). In this paper we propose a Gamma regularization based algorithm for LDCT image reconstruction. This solution is flexible and provides a good balance between the regularizations based on l0-norm and l1-norm. We evaluate the proposed approach using the projection data from simulated phantoms and scanned Catphan phantoms. Qualitative and quantitative results show that the Gamma regularization based reconstruction can perform better in both edge-preserving and noise suppression when compared with other norms.

  11. Nanosecond laser-induced back side wet etching of fused silica with a copper-based absorber liquid

    NASA Astrophysics Data System (ADS)

    Lorenz, Pierre; Zehnder, Sarah; Ehrhardt, Martin; Frost, Frank; Zimmer, Klaus; Schwaller, Patrick

    2014-03-01

    Cost-efficient machining of dielectric surfaces with high-precision and low-roughness for industrial applications is still challenging if using laser-patterning processes. Laser induced back side wet etching (LIBWE) using UV laser pulses with liquid heavy metals or aromatic hydrocarbons as absorber allows the fabrication of well-defined, nm precise, free-form surfaces with low surface roughness, e.g., needed for optical applications. The copper-sulphatebased absorber CuSO4/K-Na-Tartrate/NaOH/formaldehyde in water is used for laser-induced deposition of copper. If this absorber can also be used as precursor for laser-induced ablation, promising industrial applications combining surface structuring and deposition within the same setup could be possible. The etching results applying a KrF excimer (248 nm, 25 ns) and a Nd:YAG (1064 nm, 20 ns) laser are compared. The topography of the etched surfaces were analyzed by scanning electron microscopy (SEM), white light interferometry (WLI) as well as laser scanning microscopy (LSM). The chemical composition of the irradiated surface was studied by energy-dispersive X-ray spectroscopy (EDX) and Fourier transform infrared spectroscopy (FT-IR). For the discussion of the etching mechanism the laser-induced heating was simulated with finite element method (FEM). The results indicate that the UV and IR radiation allows micro structuring of fused silica with the copper-based absorber where the etching process can be explained by the laser-induced formation of a copper-based absorber layer.

  12. Study on the absorbed fingerprint-efficacy of yuanhu zhitong tablet based on chemical analysis, vasorelaxation evaluation and data mining.

    PubMed

    Xu, Haiyu; Li, Ke; Chen, Yanjun; Zhang, Yingchun; Tang, Shihuan; Wang, Shanshan; Shen, Dan; Wang, Xuguang; Lei, Yun; Li, Defeng; Zhang, Yi; Jin, Lan; Yang, Hongjun; Huang, Luqi

    2013-01-01

    Yuanhu Zhitong Tablet (YZT) is an example of a typical and relatively simple clinical herb formula that is widely used in clinics. It is generally believed that YZT play a therapeutical effect in vivo by the synergism of multiple constituents. Thus, it is necessary to build the relationship between the absorbed fingerprints and bioactivity so as to ensure the quality, safety and efficacy. In this study, a new combinative method, an intestinal absorption test coupled with a vasorelaxation bioactivity experiment in vitro, was a simple, sensitive, and feasible technique to study on the absorbed fingerprint-efficacy of YZT based on chemical analysis, vasorelaxation evaluation and data mining. As part of this method, an everted intestinal sac method was performed to determine the intestinal absorption of YZT solutions. YZT were dissolved in solution (n = 12), and the portion of the solution that was absorbed into intestinal sacs was analyzed using rapid-resolution liquid chromatography coupled with quadruple time-of-flight mass spectrometry (RRLC-Q-TOF/MS). Semi-quantitative analysis indicated the presence of 34 compounds. The effect of the intestinally absorbed solution on vasorelaxation of rat aortic rings with endothelium attached was then evaluated in vitro. The results showed that samples grouped by HCA from chemical profiles have similar bioactivity while samples in different groups displayed very different. Moreover, it established a relationship between the absorbed fingerprints and their bioactivity to identify important components by grey relational analysis, which could predict bioactive values based on chemical profiles and provide an evidence for the quantification of multi-constituents.

  13. Study on the Absorbed Fingerprint-Efficacy of Yuanhu Zhitong Tablet Based on Chemical Analysis, Vasorelaxation Evaluation and Data Mining

    PubMed Central

    Chen, Yanjun; Zhang, Yingchun; Tang, Shihuan; Wang, Shanshan; Shen, Dan; Wang, Xuguang; Lei, Yun; Li, Defeng; Zhang, Yi; Jin, Lan; Yang, Hongjun; Huang, Luqi

    2013-01-01

    Yuanhu Zhitong Tablet (YZT) is an example of a typical and relatively simple clinical herb formula that is widely used in clinics. It is generally believed that YZT play a therapeutical effect in vivo by the synergism of multiple constituents. Thus, it is necessary to build the relationship between the absorbed fingerprints and bioactivity so as to ensure the quality, safety and efficacy. In this study, a new combinative method, an intestinal absorption test coupled with a vasorelaxation bioactivity experiment in vitro, was a simple, sensitive, and feasible technique to study on the absorbed fingerprint-efficacy of YZT based on chemical analysis, vasorelaxation evaluation and data mining. As part of this method, an everted intestinal sac method was performed to determine the intestinal absorption of YZT solutions. YZT were dissolved in solution (n = 12), and the portion of the solution that was absorbed into intestinal sacs was analyzed using rapid-resolution liquid chromatography coupled with quadruple time-of-flight mass spectrometry (RRLC-Q-TOF/MS). Semi-quantitative analysis indicated the presence of 34 compounds. The effect of the intestinally absorbed solution on vasorelaxation of rat aortic rings with endothelium attached was then evaluated in vitro. The results showed that samples grouped by HCA from chemical profiles have similar bioactivity while samples in different groups displayed very different. Moreover, it established a relationship between the absorbed fingerprints and their bioactivity to identify important components by grey relational analysis, which could predict bioactive values based on chemical profiles and provide an evidence for the quantification of multi-constituents. PMID:24339904

  14. Nanometre optical coatings based on strong interference effects in highly absorbing media.

    PubMed

    Kats, Mikhail A; Blanchard, Romain; Genevet, Patrice; Capasso, Federico

    2013-01-01

    Optical coatings, which consist of one or more films of dielectric or metallic materials, are widely used in applications ranging from mirrors to eyeglasses and photography lenses. Many conventional dielectric coatings rely on Fabry-Perot-type interference, involving multiple optical passes through transparent layers with thicknesses of the order of the wavelength to achieve functionalities such as anti-reflection, high-reflection and dichroism. Highly absorbing dielectrics are typically not used because it is generally accepted that light propagation through such media destroys interference effects. We show that under appropriate conditions interference can instead persist in ultrathin, highly absorbing films of a few to tens of nanometres in thickness, and demonstrate a new type of optical coating comprising such a film on a metallic substrate, which selectively absorbs various frequency ranges of the incident light. These coatings have a low sensitivity to the angle of incidence and require minimal amounts of absorbing material that can be as thin as 5-20 nm for visible light. This technology has the potential for a variety of applications from ultrathin photodetectors and solar cells to optical filters, to labelling, and even the visual arts and jewellery.

  15. Angle- and polarization-insensitive metamaterial absorber based on vertical and horizontal symmetric slotted sectors.

    PubMed

    Trung, Nguyen Toan; Lee, Dongju; Sung, Hyuk-Kee; Lim, Sungjoon

    2016-10-10

    This novel vertically and horizontally symmetric slotted-sector design aims to realize an angle- and polarization-insensitive metamaterial absorber. The unit-cell symmetries achieve polarization insensitivity, while an optimized slotted-sector inner angle enables angle insensitivity. Because the absorptivity of a metamaterial absorber depends on the incident angle and polarization, many researchers have studied angle- and polarization-insensitive unit cells. In this work, a novel vertically and horizontally symmetric slotted sector is proposed in order to realize an angle- and polarization-insensitive metamaterial absorber. The absorber performance is demonstrated with full-wave simulation and measurements. Angular sensitivity is studied for different slotted-sector inner angles. For an 85° inner angle, the simulated absorptivity exceeds 90% and the frequency variation is less than 1.2% up to 70° incidence. The measured absorptivity at 10.34 GHz is close to 98.5% for all polarization angles at normal incidence. As the incidence angle varies from 0° to 70°, the measured absorptivity at 10.34 GHz remains above 90% in the transverse electric mode.

  16. Broadband Tunability of Polarization-Insensitive Absorber Based on Frequency Selective Surface

    PubMed Central

    Wang, Han; Kong, Peng; Cheng, Wentao; Bao, Wenzong; Yu, Xiaowei; Miao, Ling; Jiang, Jianjun

    2016-01-01

    An innovative tunable and polarization-insensitive 1.6–8 GHz frequency selective surface (FSS) absorber was investigated in this study. The proposed FSS, which is in 4-axial symmetrical form, includes a novel array of PIN diodes with biasing lines including inductors. A gradually reduced equivalent resistor of PIN diodes can be achieved with increasing DC voltage, which characterizes tunable, multi-resonance absorption peaks. Via this simplified design, small value resistor and equivalent capacitance of the gap between patterns can improve the absorber’s performance in low frequencies; an active tunable absorber can be realized in a broad frequency range by employing adjustable devices. Changing the working state of the PIN diode allows the user to obtain strong absorption within the desired frequency. We analyzed the performance of the proposed absorber and found that it indeed shows very favorable absorption performance in low frequency (−10 dB in 1.6−4.3 GHz) and wideband (−8 dB in 4.3−5.4 GHz and −10 dB in 5.4−8.0 GHz) conditions. Calculation and simulation results also illustrated that the absorber is entirely polarization-insensitive. PMID:26983804

  17. Nanometre optical coatings based on strong interference effects in highly absorbing media

    NASA Astrophysics Data System (ADS)

    Kats, Mikhail A.; Blanchard, Romain; Genevet, Patrice; Capasso, Federico

    2013-01-01

    Optical coatings, which consist of one or more films of dielectric or metallic materials, are widely used in applications ranging from mirrors to eyeglasses and photography lenses. Many conventional dielectric coatings rely on Fabry-Perot-type interference, involving multiple optical passes through transparent layers with thicknesses of the order of the wavelength to achieve functionalities such as anti-reflection, high-reflection and dichroism. Highly absorbing dielectrics are typically not used because it is generally accepted that light propagation through such media destroys interference effects. We show that under appropriate conditions interference can instead persist in ultrathin, highly absorbing films of a few to tens of nanometres in thickness, and demonstrate a new type of optical coating comprising such a film on a metallic substrate, which selectively absorbs various frequency ranges of the incident light. These coatings have a low sensitivity to the angle of incidence and require minimal amounts of absorbing material that can be as thin as 5-20 nm for visible light. This technology has the potential for a variety of applications from ultrathin photodetectors and solar cells to optical filters, to labelling, and even the visual arts and jewellery.

  18. Bridging the terahertz near-field and far-field observations of liquid crystal based metamaterial absorbers

    NASA Astrophysics Data System (ADS)

    Wang, Lei; Ge, Shijun; Chen, Zhaoxian; Hu, Wei; Lu, Yanqing

    2016-09-01

    Metamaterial-based absorbers play a significant role in applications ranging from energy harvesting and thermal emitters to sensors and imaging devices. The middle dielectric layer of conventional metamaterial absorbers has always been solid. Researchers could not detect the near field distribution in this layer or utilize it effectively. Here, we use anisotropic liquid crystal as the dielectric layer to realize electrically fast tunable terahertz metamaterial absorbers. We demonstrate strong, position-dependent terahertz near-field enhancement with sub-wavelength resolution inside the metamaterial absorber. We measure the terahertz far-field absorption as the driving voltage increases. By combining experimental results with liquid crystal simulations, we verify the near-field distribution in the middle layer indirectly and bridge the near-field and far-field observations. Our work opens new opportunities for creating high-performance, fast, tunable, terahertz metamaterial devices that can be applied in biological imaging and sensing. Project supported by the National Basic Research Program of China (Grant No. 2012CB921803), the National Natural Science Foundation of China (Grants Nos. 61225026, 61490714, 11304151, and 61435008), the Natural Science Foundation of Jiangsu Province, China (Grant Nos. BK20150845 and 15KJB140004), the Open Foundation Project of National Laboratory of Solid State Microstructures, China (Grant No. M28003), and the Research Center of Optical Communications Engineering & Technology, Jiangsu Province, China.

  19. Assessment of organ doses from exposure to neutrons using the Monte Carlo technique and an image-based anatomical model

    NASA Astrophysics Data System (ADS)

    Bozkurt, Ahmet

    The distribution of absorbed doses in the body can be computationally determined using mathematical or tomographic representations of human anatomy. A whole- body model was developed from the color images of the National Library of Medicine's Visible Human Project® for simulating the transport of radiation in the human body. The model, called Visible Photographic Man (VIP-Man), has sixty-one organs and tissues represented in the Monte Carlo code MCNPX at 4-mm voxel resolution. Organ dose calculations from external neutron sources were carried out using VIP-man and MCNPX to determine a new set of dose conversion coefficients to be used in radiation protection. Monoenergetic neutron beams between 10-9 MeV and 10 GeV were studied under six different irradiation geometries: anterior-posterior, posterior-anterior, right lateral, left lateral, rotational and isotropic. The results for absorbed doses in twenty-four organs and the effective doses based on twelve critical organs are presented in tabular form. A comprehensive comparison of the results with those from the mathematical models show discrepancies that can be attributed to the variations in body modeling (size, location and shape of the individual organs) and the use of different nuclear datasets or models to derive the reaction cross sections, as well as the use of different transport packages for simulation radiation effects. The organ dose results based on the realistic VIP-Man body model allow the existing radiation protection dosimetry on neutrons to be re-evaluated and improved.

  20. Organ dose conversion coefficients based on a voxel mouse model and MCNP code for external photon irradiation.

    PubMed

    Zhang, Xiaomin; Xie, Xiangdong; Cheng, Jie; Ning, Jing; Yuan, Yong; Pan, Jie; Yang, Guoshan

    2012-01-01

    A set of conversion coefficients from kerma free-in-air to the organ absorbed dose for external photon beams from 10 keV to 10 MeV are presented based on a newly developed voxel mouse model, for the purpose of radiation effect evaluation. The voxel mouse model was developed from colour images of successive cryosections of a normal nude male mouse, in which 14 organs or tissues were segmented manually and filled with different colours, while each colour was tagged by a specific ID number for implementation of mouse model in Monte Carlo N-particle code (MCNP). Monte Carlo simulation with MCNP was carried out to obtain organ dose conversion coefficients for 22 external monoenergetic photon beams between 10 keV and 10 MeV under five different irradiation geometries conditions (left lateral, right lateral, dorsal-ventral, ventral-dorsal, and isotropic). Organ dose conversion coefficients were presented in tables and compared with the published data based on a rat model to investigate the effect of body size and weight on the organ dose. The calculated and comparison results show that the organ dose conversion coefficients varying the photon energy exhibits similar trend for most organs except for the bone and skin, and the organ dose is sensitive to body size and weight at a photon energy approximately <0.1 MeV.

  1. A simple and fast physics-based analytical method to calculate therapeutic and stray doses from external beam, megavoltage x-ray therapy.

    PubMed

    Jagetic, Lydia J; Newhauser, Wayne D

    2015-06-21

    State-of-the-art radiotherapy treatment planning systems provide reliable estimates of the therapeutic radiation but are known to underestimate or neglect the stray radiation exposures. Most commonly, stray radiation exposures are reconstructed using empirical formulas or lookup tables. The purpose of this study was to develop the basic physics of a model capable of calculating the total absorbed dose both inside and outside of the therapeutic radiation beam for external beam photon therapy. The model was developed using measurements of total absorbed dose in a water-box phantom from a 6 MV medical linear accelerator to calculate dose profiles in both the in-plane and cross-plane direction for a variety of square field sizes and depths in water. The water-box phantom facilitated development of the basic physical aspects of the model. RMS discrepancies between measured and calculated total absorbed dose values in water were less than 9.3% for all fields studied. Computation times for 10 million dose points within a homogeneous phantom were approximately 4 min. These results suggest that the basic physics of the model are sufficiently simple, fast, and accurate to serve as a foundation for a variety of clinical and research applications, some of which may require that the model be extended or simplified based on the needs of the user. A potentially important advantage of a physics-based approach is that the model is more readily adaptable to a wide variety of treatment units and treatment techniques than with empirical models.

  2. Establishment of a γ-H2AX foci-based assay to determine biological dose of radon to red bone marrow in rats

    PubMed Central

    Wang, Jing; He, Linfeng; Fan, Dunhuang; Ding, Defang; Wang, Xufei; Gao, Yun; Zhang, Xuxia; Li, Qiang; Chen, Honghong

    2016-01-01

    The biodosimetric information is critical for assessment of cancer risk in populations exposed to high radon. However, no tools are available for biological dose estimation following radon exposure. Here, we established a γ-H2AX foci-based assay to determine biological dose to red bone marrow (RBM) in radon-inhaled rats. After 1–3 h of in vitro radon exposure, a specific pattern of γ-H2AX foci, linear tracks with individual p-ATM and p-DNA-PKcs foci, was observed, and the yield of γ-H2AX foci and its linear tracks displayed a linear dose-response manner in both rat peripheral blood lymphocytes (PBLs) and bone-marrow lymphocytes (BMLs). When the cumulative doses of radon inhaled by rats reached 14, 30 and 60 working level months (WLM), the yields of three types of foci markedly increased in both PBLs and BMLs, and γ-H2AX foci-based dose estimates to RBM were 0.97, 2.06 and 3.94 mGy, respectively. Notably, BMLs displayed a more profound increase of three types of foci than PBLs, and the absorbed dose ratio between BMLs and PBLs was similar between rats exposed to 30 and 60 WLM of radon. Taken together, γ-H2AX foci quantitation in PBLs is able to estimate RBM-absorbed doses with the dose-response curve of γ-H2AX foci after in vitro radon exposure and the ratio of RBM- to PBL-absorbed doses in rats following radon exposure. PMID:27445126

  3. Establishment of a γ-H2AX foci-based assay to determine biological dose of radon to red bone marrow in rats

    NASA Astrophysics Data System (ADS)

    Wang, Jing; He, Linfeng; Fan, Dunhuang; Ding, Defang; Wang, Xufei; Gao, Yun; Zhang, Xuxia; Li, Qiang; Chen, Honghong

    2016-07-01

    The biodosimetric information is critical for assessment of cancer risk in populations exposed to high radon. However, no tools are available for biological dose estimation following radon exposure. Here, we established a γ-H2AX foci-based assay to determine biological dose to red bone marrow (RBM) in radon-inhaled rats. After 1–3 h of in vitro radon exposure, a specific pattern of γ-H2AX foci, linear tracks with individual p-ATM and p-DNA-PKcs foci, was observed, and the yield of γ-H2AX foci and its linear tracks displayed a linear dose-response manner in both rat peripheral blood lymphocytes (PBLs) and bone-marrow lymphocytes (BMLs). When the cumulative doses of radon inhaled by rats reached 14, 30 and 60 working level months (WLM), the yields of three types of foci markedly increased in both PBLs and BMLs, and γ-H2AX foci-based dose estimates to RBM were 0.97, 2.06 and 3.94 mGy, respectively. Notably, BMLs displayed a more profound increase of three types of foci than PBLs, and the absorbed dose ratio between BMLs and PBLs was similar between rats exposed to 30 and 60 WLM of radon. Taken together, γ-H2AX foci quantitation in PBLs is able to estimate RBM-absorbed doses with the dose-response curve of γ-H2AX foci after in vitro radon exposure and the ratio of RBM- to PBL-absorbed doses in rats following radon exposure.

  4. Using rule-based shot dose assignment in model-based MPC applications

    NASA Astrophysics Data System (ADS)

    Bork, Ingo; Buck, Peter; Wang, Lin; Müller, Uwe

    2014-10-01

    Shrinking feature sizes and the need for tighter CD (Critical Dimension) control require the introduction of new technologies in mask making processes. One of those methods is the dose assignment of individual shots on VSB (Variable Shaped Beam) mask writers to compensate CD non-linearity effects and improve dose edge slope. Using increased dose levels only for most critical features, generally only for the smallest CDs on a mask, the change in mask write time is minimal while the increase in image quality can be significant. This paper describes a method combining rule-based shot dose assignment with model-based shot size correction. This combination proves to be very efficient in correcting mask linearity errors while also improving dose edge slope of small features. Shot dose assignment is based on tables assigning certain dose levels to a range of feature sizes. The dose to feature size assignment is derived from mask measurements in such a way that shape corrections are kept to a minimum. For example, if a 50nm drawn line on mask results in a 45nm chrome line using nominal dose, a dose level is chosen which is closest to getting the line back on target. Since CD non-linearity is different for lines, line-ends and contacts, different tables are generated for the different shape categories. The actual dose assignment is done via DRC rules in a pre-processing step before executing the shape correction in the MPC engine. Dose assignment to line ends can be restricted to critical line/space dimensions since it might not be required for all line ends. In addition, adding dose assignment to a wide range of line ends might increase shot count which is undesirable. The dose assignment algorithm is very flexible and can be adjusted based on the type of layer and the best balance between accuracy and shot count. These methods can be optimized for the number of dose levels available for specific mask writers. The MPC engine now needs to be able to handle different dose

  5. Adaptive dose finding based on t-statistic for dose-response trials.

    PubMed

    Ivanova, Anastasia; Bolognese, James A; Perevozskaya, Inna

    2008-05-10

    The goals of phase II dose-response studies are to prove that the treatment is effective and to choose the dose for further development. Randomized designs with equal allocation to either a high dose and placebo or to each of several doses and placebo are typically used. However, in trials where response is observed relatively quickly, adaptive designs might offer an advantage over equal allocation. We propose an adaptive design for dose-response trials that concentrates the allocation of subjects in one or more areas of interest, for example, near a minimum clinically important effect level, or near some maximal effect level, and also allows for the possibility to stop the trial early if needed. The proposed adaptive design yields higher power to detect a dose-response relationship, higher power in comparison with placebo, and selects the correct dose more frequently compared with a corresponding randomized design with equal allocation to doses.

  6. Sound Absorbers

    NASA Astrophysics Data System (ADS)

    Fuchs, H. V.; Möser, M.

    Sound absorption indicates the transformation of sound energy into heat. It is, for instance, employed to design the acoustics in rooms. The noise emitted by machinery and plants shall be reduced before arriving at a workplace; auditoria such as lecture rooms or concert halls require a certain reverberation time. Such design goals are realised by installing absorbing components at the walls with well-defined absorption characteristics, which are adjusted for corresponding demands. Sound absorbers also play an important role in acoustic capsules, ducts and screens to avoid sound immission from noise intensive environments into the neighbourhood.

  7. Flexible and elastic metamaterial absorber for low frequency, based on small-size unit cell

    SciTech Connect

    Yoo, Y. J.; Zheng, H. Y.; Kim, Y. J.; Lee, Y. P.; Rhee, J. Y.; Kang, J.-H.; Kim, K. W.; Cheong, H.; Kim, Y. H.

    2014-07-28

    Using a planar and flexible metamaterial (MM), we obtained the low-frequency perfect absorption even with very small unit-cell size in snake-shape structure. These shrunken, deep-sub-wavelength and thin MM absorbers were numerically and experimentally investigated by increasing the inductance. The periodicity/thickness (the figure of merit for perfect absorption) is achieved to be 10 and 2 for single-snake-bar and 5-snake-bar structures, respectively. The ratio between periodicity and resonance wavelength (in mm) is close to 1/12 and 1/30 at 2 GHz and 400 MHz, respectively. The absorbers are specially designed for absorption peaks around 2 GHz and 400 MHz, which can be used for depressing the electromagnetic noise from everyday electronic devices and mobile phones.

  8. Black phosphorus-based saturable absorber for Q-switched Tm:YAG ceramic laser

    NASA Astrophysics Data System (ADS)

    Xie, Yixuan; Kong, Lingchen; Qin, Zhipeng; Xie, Guoqiang; Zhang, Jian

    2016-08-01

    We have experimentally demonstrated a passively Q-switched Tm-doped YAG ceramic laser with black phosphorus (BP) as saturable absorber (SA). According to the measurement, the BP saturable absorber mirror has a modulation depth of 5% and a saturation fluence of 20 μJ/cm2. The generated Q-switched pulse has a maximum average power of 38.5 mW and pulse energy of 3.32 μJ, with the corresponding repetition rate of 11.6 KHz and pulse width of 3.12 μs at 2 μm wavelength. The results show that BP is a promising SA for midinfrared-pulsed lasers.

  9. Black phosphorus based saturable absorber for Nd-ion doped pulsed solid state laser operation

    NASA Astrophysics Data System (ADS)

    Han, S.; Zhang, F.; Wang, M.; Wang, L.; Zhou, Y.; Wang, Z.; Xu, X.

    2016-12-01

    In this paper, the use of black phosphorus (BP) as a saturable absorber in a Q-switched Nd-ion doped solid state laser is presented. Few layers of BP in isopropyl alcohol are obtained by liquid phase exfoliation. The BP nanosheets with thicknesses in the range of 15-20 nm are deposited onto a K9 glass substrate. By inserting the BP nanosheets into a diode pumped Nd-ion doped solid state laser, stable Q-switched lasing at 0.9, 1.06, 1.3 μm is obtained. Using this approach, we have achieved a short pulse duration down to 219 ns, a high pulse energy of up to 6.5 μJ, and the corresponding peak power of 30 W. Our results show that the BP saturable absorber functions well in a Nd-ion doped solid state laser for pulsed laser generation.

  10. Black phosphorus based saturable absorber for Nd-ion doped pulsed solid state laser operation

    NASA Astrophysics Data System (ADS)

    Han, S.; Zhang, F.; Wang, M.; Wang, L.; Zhou, Y.; Wang, Z.; Xu, X.

    2017-04-01

    In this paper, the use of black phosphorus (BP) as a saturable absorber in a Q-switched Nd-ion doped solid state laser is presented. Few layers of BP in isopropyl alcohol are obtained by liquid phase exfoliation. The BP nanosheets with thicknesses in the range of 15-20 nm are deposited onto a K9 glass substrate. By inserting the BP nanosheets into a diode pumped Nd-ion doped solid state laser, stable Q-switched lasing at 0.9, 1.06, 1.3 μm is obtained. Using this approach, we have achieved a short pulse duration down to 219 ns, a high pulse energy of up to 6.5 μJ, and the corresponding peak power of 30 W. Our results show that the BP saturable absorber functions well in a Nd-ion doped solid state laser for pulsed laser generation.

  11. Dielectric-based subwavelength metallic meanders for wide-angle band absorbers.

    PubMed

    Shen, Su; Qiao, Wen; Ye, Yan; Zhou, Yun; Chen, Linsen

    2015-01-26

    We propose nano-meanders that can achieve wide-angle band absorption in visible regime. The nano-meander consists of a subwavelength dielectric grating covered by continuous ultra-thin Aluminum film (less than one tenth of the incident wavelength). The excited photonic resonant modes, such as cavity mode, surface plasmonic mode and Rayleigh-Wood anomaly, are discussed in detail. Nearly total resonant absorption due to funneling mechanism in the air nano-groove is almost invariant with large incident angle in transverse magnetic polarization. From both the structural geometry and the nanofabrication point of view, the light absorber has a very simple geometrical structure and it is easy to be integrated into complex photonic devices. The highly efficient angle-robust light absorber can be potential candidate for a range of passive and active photonic applications, including solar-energy harvesting as well as producing artificial colors on a large scale substrate.

  12. Semi-active vibration absorber based on real-time controlled MR damper

    NASA Astrophysics Data System (ADS)

    Weber, F.

    2014-06-01

    A semi-active vibration absorber with real-time controlled magnetorheological damper (MR-SVA) for the mitigation of harmonic structural vibrations is presented. The MR damper force targets to realize the frequency and damping adaptations to the actual structural frequency according to the principle of the undamped vibration absorber. The relative motion constraint of the MR-SVA is taken into account by an adaptive nonlinear control of the internal damping of the MR-SVA. The MR-SVA is numerically and experimentally validated for harmonic excitation of the primary structure when the natural frequency of the passive mass spring system of the MR-SVA is correctly tuned to the targeted structural resonance frequency and when de-tuning is present. The results demonstrate that the MR-SVA outperforms the passive TMD at structural resonance frequency by at least 12.4% and up to 60.0%.

  13. Design of UV-Absorbing Polypropylene Films with Polymeric Benzotriaziole Based Nano- and Microparticle Coatings.

    PubMed

    Cohen, Sarit; Haham, Hai; Pellach, Michal; Margel, Shlomo

    2017-01-11

    UV-absorbing nanoparticles (NPs) and microparticles (MPs) were prepared by emulsion and dispersion copolymerization of the vinylic monomer 2-(2'-hydroxy-5'-methacryloxyethylphenyl)-2H-benzotriazole (Norbloc (NB)) with the crosslinking monomer divinylbenzene. The effect of the initiator concentration on the size and size distribution of the polyNB (PNB) particles was elucidated. Thin coatings of the formed PNB NPs or MPs of 19 ± 2 and 200 ± 25 nm dry diameter, respectively, onto polypropylene (PP) films were then prepared and characterized. Increasing the concentration or thickness of the PNB NP or MP thin coatings on the PP films decreased their UV transmittance, up to complete UV blocking with just 2 μm of a 4% NP coating. Migration of the UV-absorbing agents from the coated PP films was not observed during three years of storage at room temperature, offering a unique solution to current problems of migration of UV-absorbing additives. The thin coatings obtained by the PNB NPs were superior to those of the PNB MPs, in that no UV transmittance or loss of optical properties of the PP films were observed for the NP coatings, while the coatings produced by the PNB MPs resulted in damaged optical properties, particularly increasing the haze, and achieved incomplete UV blocking.

  14. Solar-thermophotovoltaic systems using spectrally selective absorber/emitter based on metal-dielectric multilayer

    NASA Astrophysics Data System (ADS)

    Kohiyama, A.; Shimizu, M.; Yugami, H.

    2016-09-01

    In this paper, high-efficiency STPV systems are investigated using spectrally selective absorber/emitter consisted of metal-dielectric multilayer and a GaSb TPV cell. A solar-thermophotovoltaic (STPV) system is expected to as highefficiency solar energy conversion using single-junction photovoltaic (PV) cells. However, the reached experimental system efficiency has been still low because spectral control of emitter is not sufficient. Narrowband thermal radiation from the emitter is effective for obtaining high-efficiency STPV systems, exceeding the Shockley-Queisser limit. From theoretical analysis, the narrowband thermal emitter can leads to obtain PV conversion efficiency over 45% at Qvalue= 30 and 1300K. The spectrally selective absorber/emitter was also investigated to obtain high ηPV. The ηPV = 23.5% was estimated by the fabricated emitter spectrum, which exceeds the Shockley-Queisser limit of 19.6% for a GaSb bandgap of 0.67 eV. The entire STPV system and the power generation tests were conducted using the fabricated absorber/emitter. The total system efficiency 4.9% at 1505K was obtained under an irradiance of 109 Wcm-2.

  15. Expanded graphite—Phenolic resin composites based double layer microwave absorber for X-band applications

    NASA Astrophysics Data System (ADS)

    Gogoi, Jyoti Prasad; Bhattacharyya, Nidhi Saxena

    2014-11-01

    In this investigation, double layer microwave absorbers are designed and developed with paired combination of 5 wt. %, 7 wt. %, 8 wt. %, and 10 wt. % expanded graphite-novolac phenolic resin (EG-NPR) composites, in the frequency range of 8.2-12.4 GHz. The thickness and compositional combination of the two layers constituting the absorber are optimized to achieve minimum value of reflection loss (dB) and a broad microwave absorption bandwidth. Double layer combinations showing -25 dB absorption bandwidth >2 GHz and -30 dB absorption bandwidth >1 GHz are chosen for fabrication. The total thickness of the fabricated double layer microwave absorber is varied from 3 mm to 3.4 mm. Absorption bandwidths at -10 dB, -20 dB, -25 dB and -30 dB are determined for the fabricated structure. The maximum -25 dB and -30 dB absorption bandwidth of 2.47 GHz and 1.77 GHz, respectively, are observed for the double layer structure with (5 wt. %-8 wt. %) EG-NPR composites with total thickness of 3.2 mm, while -10 dB bandwidth covers the entire X-band range.

  16. Phantoms for diffuse optical imaging based on totally absorbing objects, part 1: Basic concepts.

    PubMed

    Martelli, Fabrizio; Pifferi, Antonio; Contini, Davide; Spinelli, Lorenzo; Torricelli, Alessandro; Wabnitz, Heidrun; Macdonald, Rainer; Sassaroli, Angelo; Zaccanti, Giovanni

    2013-06-01

    The design of inhomogeneous phantoms for diffuse optical imaging purposes using totally absorbing objects embedded in a diffusive medium is proposed and validated. From time-resolved and continuous-wave Monte Carlo simulations, it is shown that a given or desired perturbation strength caused by a realistic absorbing inhomogeneity of a certain absorption and volume can be approximately mimicked by a small totally absorbing object of a so-called equivalent black volume (equivalence relation). This concept can be useful in two ways. First, it can be exploited to design realistic inhomogeneous phantoms with different perturbation strengths simply using a set of black objects with different volumes. Further, it permits one to grade physiological or pathological changes on a reproducible scale of perturbation strengths given as equivalent black volumes, thus facilitating the performance assessment of clinical instruments. A set of plots and interpolating functions to derive the equivalent black volume corresponding to a given absorption change is provided. The application of the equivalent black volume concept for grading different optical perturbations is demonstrated for some examples.

  17. Dosimetry in Mammography: Average Glandular Dose Based on Homogeneous Phantom

    NASA Astrophysics Data System (ADS)

    Benevides, Luis A.; Hintenlang, David E.

    2011-05-01

    The objective of this study was to demonstrate that a clinical dosimetry protocol that utilizes a dosimetric breast phantom series based on population anthropometric measurements can reliably predict the average glandular dose (AGD) imparted to the patient during a routine screening mammogram. AGD was calculated using entrance skin exposure and dose conversion factors based on fibroglandular content, compressed breast thickness, mammography unit parameters and modifying parameters for homogeneous phantom (phantom factor), compressed breast lateral dimensions (volume factor) and anatomical features (anatomical factor). The patient fibroglandular content was evaluated using a calibrated modified breast tissue equivalent homogeneous phantom series (BRTES-MOD) designed from anthropomorphic measurements of a screening mammography population and whose elemental composition was referenced to International Commission on Radiation Units and Measurements Report 44 and 46 tissues. The patient fibroglandular content, compressed breast thickness along with unit parameters and spectrum half-value layer were used to derive the currently used dose conversion factor (DgN). The study showed that the use of a homogeneous phantom, patient compressed breast lateral dimensions and patient anatomical features can affect AGD by as much as 12%, 3% and 1%, respectively. The protocol was found to be superior to existing methodologies. The clinical dosimetry protocol developed in this study can reliably predict the AGD imparted to an individual patient during a routine screening mammogram.

  18. Dosimetry in Mammography: Average Glandular Dose Based on Homogeneous Phantom

    SciTech Connect

    Benevides, Luis A.; Hintenlang, David E.

    2011-05-05

    The objective of this study was to demonstrate that a clinical dosimetry protocol that utilizes a dosimetric breast phantom series based on population anthropometric measurements can reliably predict the average glandular dose (AGD) imparted to the patient during a routine screening mammogram. AGD was calculated using entrance skin exposure and dose conversion factors based on fibroglandular content, compressed breast thickness, mammography unit parameters and modifying parameters for homogeneous phantom (phantom factor), compressed breast lateral dimensions (volume factor) and anatomical features (anatomical factor). The patient fibroglandular content was evaluated using a calibrated modified breast tissue equivalent homogeneous phantom series (BRTES-MOD) designed from anthropomorphic measurements of a screening mammography population and whose elemental composition was referenced to International Commission on Radiation Units and Measurements Report 44 and 46 tissues. The patient fibroglandular content, compressed breast thickness along with unit parameters and spectrum half-value layer were used to derive the currently used dose conversion factor (DgN). The study showed that the use of a homogeneous phantom, patient compressed breast lateral dimensions and patient anatomical features can affect AGD by as much as 12%, 3% and 1%, respectively. The protocol was found to be superior to existing methodologies. The clinical dosimetry protocol developed in this study can reliably predict the AGD imparted to an individual patient during a routine screening mammogram.

  19. Lipid-absorbing Polymers

    NASA Technical Reports Server (NTRS)

    Marsh, H. E., Jr.; Wallace, C. J.

    1973-01-01

    The removal of bile acids and cholesterol by polymeric absorption is discussed in terms of micelle-polymer interaction. The results obtained with a polymer composed of 75 parts PEO and 25 parts PB plus curing ingredients show an absorption of 305 to 309%, based on original polymer weight. Particle size effects on absorption rate are analyzed. It is concluded that crosslinked polyethylene oxide polymers will absorb water, crosslinked polybutadiene polymers will absorb lipids; neither polymer will absorb appreciable amounts of lipids from micellar solutions of lipids in water.

  20. Dataset demonstrating the modeling of a high performance Cu(In,Ga)Se2 absorber based thin film photovoltaic cell.

    PubMed

    Asaduzzaman, Md; Bahar, Ali Newaz; Bhuiyan, Mohammad Maksudur Rahman

    2017-04-01

    The physical data of the semiconductor materials used in the design of a CIGS absorber based thin film photovoltaic cell have been presented in this data article. Besides, the values of the contact parameter and operating conditions of the cell have been reported. Furthermore, by conducting the simulation with data corresponding to the device structure: soda-lime glass (SLG) substrate/Mo back-contact/CIGS absorber/CdS buffer/intrinsic ZnO/Al-doped ZnO window/Al-grid front-contact, the solar cell performance parameters such as open circuit voltage [Formula: see text], short circuit current density [Formula: see text], fill factor [Formula: see text], efficiency [Formula: see text], and collection efficiency [Formula: see text] have been analyzed.

  1. Investigations into alterntive substrate, absorber, and buffer layer processing for Cu(In,Ga)Se{sub 2}-based solar cells

    SciTech Connect

    Tuttle, J.R.; Berens, T.A.; Keane, J.

    1996-05-01

    High-performance Cu(In,Ga)Se{sub 2}(CIGS)-based solar cells are presently fabricated within a narrow range of processing options. In this contribution, alternative substrate, absorber, and buffer layer processing is considered. Cell performance varies considerably when alternative substrates are employed. These variations are narrowed with the addition of Na via a Na{sub 2}S compound. Sputtered and electrodeposited CIGS precursors and completed absorbers show promise as alternatives to evaporation. A recrystallization process is required to improve their quality. (In,Ga){sub y}Se buffer layers contribute to cell performance above 10. Further improvements in these alternatives will lead to combined cell performance greater than 10% in the near term.

  2. Fluence-to-dose conversion coefficients based on the VIP-Man anatomical model and MCNPX code for monoenergetic neutrons above 20 MeV.

    PubMed

    Bozkurt, A; Chao, T C; Xu, X G

    2001-08-01

    A new set of fluence-to-absorbed dose and fluence-to-effective dose conversion coefficients has been calculated for high-energy neutrons using a whole-body anatomical model, VIP-Man, developed from the high-resolution transversal color photographic images of the National Library of Medicine's Visible Human Project. Organ dose calculations were performed using the Monte Carlo code MCNPX for 20 monoenergetic neutron beams between 20 MeV and 10,000 MeV under 6 different irradiation geometries: anterior-posterior, posterior-anterior, left lateral, right lateral, isotropic, and rotational. For neutron Monte Carlo calculations, results based on an image-based whole-body model were not available in the literature. The absorbed dose results for 24 major organs of VIP-Man are presented in the form of tables and selected figures that compare with those based on simplified mathematical phantoms reported in the literature. VIP-Man yields up to 40% larger values of effective dose and many organ doses, thus suggesting that the results reported in the past may not be conservative.

  3. USE OF PBPK MODELS FOR ASSESSING ABSORBED DOSE AND CHE INHIBITION FROM AGGREGATE EXPOSURE OF INFANTS AND CHILDREN TO ORGANOPHOSPHORUS INSECTICIDES

    EPA Science Inventory

    A physiological pharmacokinetic (PBPK) modeling framework has been established to assess cumulative risk of dose and injury of infants and children to organophosphorus (OP) insecticides from aggregate sources and routes. Exposure inputs were drawn from all reasonable sources, pr...

  4. Numerical modeling of mode-locked fiber lasers with a fiber-based saturable-absorber

    NASA Astrophysics Data System (ADS)

    Wang, Long; Chong, Andy; Haus, Joseph W.

    2017-01-01

    We report fiber laser simulations with a fiber compatible, self-focusing, saturable absorber (SA) device. The SA device consists of two tapered fiber ends separated by a bulk, nonlinear medium. An optical beam transmitted from one tapered fiber end, propagate through the nonlinear medium (chalcogenide glass As40 S e60) and couples back into the other tapered fiber end. Pulse propagation in the fiber laser cavity is performed using the Split Step Method. Stable pulses are generated with energies around 0.3 nJ and a transform limited pulse width around 200 fs.

  5. Investigation of conformal and intensity-modulated radiation therapy techniques to determine the absorbed fetal dose in pregnant patients with breast cancer

    SciTech Connect

    Öğretici, Akın Akbaş, Uğur; Köksal, Canan; Bilge, Hatice

    2016-07-01

    The aim of this research was to investigate the fetal doses of pregnant patients undergoing conformal radiotherapy or intensity-modulated radiation therapy (IMRT) for breast cancers. An Alderson Rando phantom was chosen to simulate a pregnant patient with breast cancer who is receiving radiation therapy. This phantom was irradiated using the Varian Clinac DBX 600 system (Varian Medical System, Palo Alto, CA) linear accelerator, according to the standard treatment plans of both three-dimensional conformal radiation therapy (3-D CRT) and IMRT techniques. Thermoluminescent dosimeters were used to measure the irradiated phantom's virtually designated uterus area. Thermoluminescent dosimeter measurements (in the phantom) revealed that the mean cumulative fetal dose for 3-D CRT is 1.39 cGy and for IMRT it is 8.48 cGy, for a pregnant breast cancer woman who received radiation treatment of 50 Gy. The fetal dose was confirmed to increase by 70% for 3-D CRT and 40% for IMRT, if it is closer to the irradiated field by 5 cm. The mean fetal dose from 3-D CRT is 1.39 cGy and IMRT is 8.48 cGy, consistent with theoretic calculations. The IMRT technique causes the fetal dose to be 5 times more than that of 3-D CRT. Theoretic knowledge concerning the increase in the peripheral doses as the measurements approached the beam was also practically proven.

  6. Watt-level passively Q-switched double-cladding fiber laser based on graphene oxide saturable absorber.

    PubMed

    Yu, Zhenhua; Song, Yanrong; Dong, Xinzheng; Li, Yanlin; Tian, Jinrong; Wang, Yonggang

    2013-10-10

    A watt-level passively Q-switched ytterbium-doped double-cladding fiber laser with a graphene oxide (GO) absorber was demonstrated. The structure of the GO saturable absorber mirror (GO-SAM) was of the sandwich type. A maximum output power of 1.8 W was obtained around a wavelength of 1044 nm. To the best of our knowledge, this is the highest output power in Q-switched fiber lasers based on a GO saturable absorber. The pure GO was protected from the oxygen in the air so that the damage threshold of the GO-SAM was effectively raised. The gain fiber was a D-shaped ytterbium-doped double-cladding fiber. The pulse repetition rates were tuned from 120 to 215 kHz with pump powers from 3.89 to 7.8 W. The maximum pulse energy was 8.37 μJ at a pulse width of 1.7 μs.

  7. Wide-angle, polarization-insensitive and broadband absorber based on eight-fold symmetric SRRs metamaterial

    NASA Astrophysics Data System (ADS)

    Wu, Dong; Liu, Yumin; Yu, Zhongyuan; Chen, Lei; Ma, Rui; Li, Yutong; Li, Ruifang; Ye, Han

    2016-12-01

    In this paper, we propose a novel three dimensional metamaterial design with eight-fold rotational symmetry that shows a polarization-insensitive, wide-angle and broadband perfect absorption in the microwave band. By simulation, the polarization-insensitive absorption is over 90% between 26.9 GHz to 32.9 GHz, and the broadband absorption remains a good absorption performance to a wide incident angles for both TE and TM polarizations. The magnetic field distribution are investigated to interpret the physical mechanism of broadband absorption. The broadband absorption is based on overlapping the multiple magnetic resonances at the neighboring frequencies by coupling effects of multiple metallic split-ring resonators (SRRs). Moreover, it is demonstrate that the designed structure can be extended to other frequencies by scale down the size of the unit cell, such as the visible frequencies. The simulated results show that the absorption of the smaller absorber is above 90% in the frequency range from 467 THz to 765 THz(392-642 nm), which include orange to purple light in visible region(400-760nm). The wide-angle and polarization-insensitive stabilities of the smaller absorber is also demonstrated at visible region. The proposed work provides a new design of realization of a polarization-insensitive, wide-angle and broadband absorber ranging different frequency bands, and such a structure has potential application in the fields of solar cell, imaging and detection.

  8. Electromagnetically induced transparency of a plasmonic metamaterial light absorber based on multilayered metallic nanoparticle sheets

    PubMed Central

    Okamoto, Koichi; Tanaka, Daisuke; Degawa, Ryo; Li, Xinheng; Wang, Pangpang; Ryuzaki, Sou; Tamada, Kaoru

    2016-01-01

    In this study, we observed the peak splitting of absorption spectra for two-dimensional sheets of silver nanoparticles due to the electromagnetically induced transparency (EIT) effect. This unique optical phenomenon was observed for the multilayered nanosheets up to 20 layers on a metal substrate, while this phenomenon was not observed on a transparent substrate. The wavelength and intensities of the split peaks depend on the number of layers, and the experimental results were well reproduced by the calculation of the Transfer-Matrix method by employing the effective medium approximation. The Ag nanosheets used in this study can act as a plasmonic metamaterial light absorber, which has a such large oscillator strength. This phenomenon is a fundamental optical property of a thin film on a metal substrate but has never been observed because native materials do not have a large oscillator strength. This new type of EIT effect using a plasmonic metamaterial light absorber presents the potential for the development of future optic and photonic technologies. PMID:27824071

  9. Tunable graphene-based mid-infrared plasmonic wide-angle narrowband perfect absorber

    PubMed Central

    Li, Hongju; Wang, Lingling; Zhai, Xiang

    2016-01-01

    In this paper, the periodic double-layer graphene ribbon arrays placed near a metallic ground plate coated by a dielectric layer are proposed and analyzed by the coupled-mode theory (CMT) to predict the perfect absorption response in the mid-infrared region. Numerical simulations of the finite-difference time-domain (FDTD) method confirm this effect and give the underlying physical origin. The anti-symmetric dipole-dipole coupling mode is supported by the double-layer graphene ribbons and acts as the electrical resonance to suppress the reflection, because of the impedance matching. The transmission from this system is restricted by the ultra-thick metallic ground plate. All incident electromagnetic energy is efficiently confined in the interlayer between graphene ribbons and the metallic plate, and the dramatic narrowband perfect absorption peak with the FWHM (full width at half maximums) of 300 nm hence is achieved. The spectral position of the absorption peak can be dynamically tuned by a small change in the chemical potential of graphene, in addition to varying geometrical parameters of the absorber. Meanwhile, this device exhibits good absorption stability over a wide angle range of incidence around ± 60° at least. Such absorber will benefit the fabrication of mid-infrared nano-photonic devices for optical filtering and storage. PMID:27845350

  10. Electromagnetically induced transparency of a plasmonic metamaterial light absorber based on multilayered metallic nanoparticle sheets.

    PubMed

    Okamoto, Koichi; Tanaka, Daisuke; Degawa, Ryo; Li, Xinheng; Wang, Pangpang; Ryuzaki, Sou; Tamada, Kaoru

    2016-11-08

    In this study, we observed the peak splitting of absorption spectra for two-dimensional sheets of silver nanoparticles due to the electromagnetically induced transparency (EIT) effect. This unique optical phenomenon was observed for the multilayered nanosheets up to 20 layers on a metal substrate, while this phenomenon was not observed on a transparent substrate. The wavelength and intensities of the split peaks depend on the number of layers, and the experimental results were well reproduced by the calculation of the Transfer-Matrix method by employing the effective medium approximation. The Ag nanosheets used in this study can act as a plasmonic metamaterial light absorber, which has a such large oscillator strength. This phenomenon is a fundamental optical property of a thin film on a metal substrate but has never been observed because native materials do not have a large oscillator strength. This new type of EIT effect using a plasmonic metamaterial light absorber presents the potential for the development of future optic and photonic technologies.

  11. Tunable graphene-based mid-infrared plasmonic wide-angle narrowband perfect absorber

    NASA Astrophysics Data System (ADS)

    Li, Hongju; Wang, Lingling; Zhai, Xiang

    2016-11-01

    In this paper, the periodic double-layer graphene ribbon arrays placed near a metallic ground plate coated by a dielectric layer are proposed and analyzed by the coupled-mode theory (CMT) to predict the perfect absorption response in the mid-infrared region. Numerical simulations of the finite-difference time-domain (FDTD) method confirm this effect and give the underlying physical origin. The anti-symmetric dipole-dipole coupling mode is supported by the double-layer graphene ribbons and acts as the electrical resonance to suppress the reflection, because of the impedance matching. The transmission from this system is restricted by the ultra-thick metallic ground plate. All incident electromagnetic energy is efficiently confined in the interlayer between graphene ribbons and the metallic plate, and the dramatic narrowband perfect absorption peak with the FWHM (full width at half maximums) of 300 nm hence is achieved. The spectral position of the absorption peak can be dynamically tuned by a small change in the chemical potential of graphene, in addition to varying geometrical parameters of the absorber. Meanwhile, this device exhibits good absorption stability over a wide angle range of incidence around ± 60° at least. Such absorber will benefit the fabrication of mid-infrared nano-photonic devices for optical filtering and storage.

  12. Electromagnetically induced transparency of a plasmonic metamaterial light absorber based on multilayered metallic nanoparticle sheets

    NASA Astrophysics Data System (ADS)

    Okamoto, Koichi; Tanaka, Daisuke; Degawa, Ryo; Li, Xinheng; Wang, Pangpang; Ryuzaki, Sou; Tamada, Kaoru

    2016-11-01

    In this study, we observed the peak splitting of absorption spectra for two-dimensional sheets of silver nanoparticles due to the electromagnetically induced transparency (EIT) effect. This unique optical phenomenon was observed for the multilayered nanosheets up to 20 layers on a metal substrate, while this phenomenon was not observed on a transparent substrate. The wavelength and intensities of the split peaks depend on the number of layers, and the experimental results were well reproduced by the calculation of the Transfer-Matrix method by employing the effective medium approximation. The Ag nanosheets used in this study can act as a plasmonic metamaterial light absorber, which has a such large oscillator strength. This phenomenon is a fundamental optical property of a thin film on a metal substrate but has never been observed because native materials do not have a large oscillator strength. This new type of EIT effect using a plasmonic metamaterial light absorber presents the potential for the development of future optic and photonic technologies.

  13. Nanostructured thin film-based near-infrared tunable perfect absorber using phase-change material

    NASA Astrophysics Data System (ADS)

    Kocer, Hasan

    2015-01-01

    Nanostructured thin film absorbers embedded with phase-change thermochromic material can provide a large level of absorption tunability in the near-infrared region. Vanadium dioxide was employed as the phase-change material in the designed structures. The optical absorption properties of the designed structures with respect to the geometric and material parameters were systematically investigated using finite-difference time-domain computations. Absorption level of the resonance wavelength in the near-IR region was tuned from the perfect absorption level to a low level (17%) with a high positive dynamic range of near-infrared absorption intensity tunability (83%). Due to the phase transition of vanadium dioxide, the resonance at the near-infrared region is being turned on and turned off actively and reversibly under the thermal bias, thereby rendering these nanostructures suitable for infrared camouflage, emitters, and sensors.

  14. A new approach to account for the medium-dependent effect in model-based dose calculations for kilovoltage x-rays.

    PubMed

    Pawlowski, Jason M; Ding, George X

    2011-07-07

    This study presents a new approach to accurately account for the medium-dependent effect in model-based dose calculations for kilovoltage (kV) x-rays. This approach is based on the hypothesis that the correction factors needed to convert dose from model-based dose calculations to