  1. Atomic Absorption, Atomic Fluorescence, and Flame Emission Spectrometry.

    ERIC Educational Resources Information Center

    Horlick, Gary

    1984-01-01

    This review is presented in six sections. Sections focus on literature related to: (1) developments in instrumentation, measurement techniques, and procedures; (2) performance studies of flames and electrothermal atomizers; (3) applications of atomic absorption spectrometry; (4) analytical comparisons; (5) atomic fluorescence spectrometry; and (6)…

  2. Comparison of absorption, fluorescence, and polarization spectroscopy of atomic rubidium

    NASA Astrophysics Data System (ADS)

    Ashman, Seth; Stifler, Cayla; Romero, Joaquin

    2015-05-01

    An ongoing spectroscopic investigation of atomic rubidium utilizes a two-photon, single-laser excitation process. Transitions accessible with our tunable laser include 5P1 / 2F' <-- 5S1 / 2 F and 5P3 / 2F' <-- 5S1 / 2 F . The laser is split into a pump and probe beam to allow for Doppler-free measurements of transitions between hyperfine levels. The pump and probe beams are overlapped in a counter-propagating geometry and the laser frequency scans over a transition. Absorption, fluorescence and polarization spectroscopy techniques are applied to this basic experimental setup. The temperature of the vapor cell and the power of the pump and probe beams have been varied to explore line broadening effects and signal-to-noise of each technique. This humble setup will hopefully grow into a more robust experimental arrangement in which double resonance, two-laser excitations are used to explore hyperfine state changing collisions between rubidium atoms and noble gas atoms. Rb-noble gas collisions can transfer population between hyperfine levels, such as 5P3 / 2 (F' = 3) <-- Collision 5P3 / 2 (F ' = 2) , and the probe beam couples 7S1 / 2 (F'' = 2) <-- 5P3 / 2 (F' = 3) . Polarization spectroscopy signal depends on the rate of population transfer due to the collision as well as maintaining the orientation created by the pump laser. Fluorescence spectroscopy relies only on transfer of population due to the collision. Comparison of these techniques yields information regarding the change of the magnetic sublevels, mF, during hyperfine state changing collisions.

  3. Ground state bromine atom density measurements by two-photon absorption laser-induced fluorescence

    NASA Astrophysics Data System (ADS)

    Sirse, N.; Foucher, M.; Chabert, P.; Booth, J.-P.

    2014-12-01

    Ground state bromine atom detection by two-photon absorption laser-induced fluorescence (TALIF) is demonstrated. The (4p5) {^2Po3/2} bromine atoms are excited by two-photon absorption at 252.594 nm to the (5p) {^4So3/2} state and detected by 635.25 nm fluorescence to the (5s) 4P5/2 state. The atoms are generated in a radio-frequency inductively-coupled plasma in pure HBr. The excitation laser also causes some photodissociation of HBr molecules, but this can be minimized by not focussing the laser beam, still giving adequate signal levels. We determined the natural lifetime of the emitting (5p) {^4So3/2} state, τf^Br*=30.9 +/- 1.4 ns and the rate constant for quenching of this state by collision with HBr molecules, k_HBrQ = 1.02 +/- 0.07× 10-15 m3 s-1 .

  4. Determination of mercury distribution inside spent compact fluorescent lamps by atomic absorption spectrometry.

    PubMed

    Rey-Raap, Natalia; Gallardo, Antonio

    2012-05-01

    In this study, spent compact fluorescent lamps were characterized to determine the distribution of mercury. The procedure used in this research allowed mercury to be extracted in the vapor phase, from the phosphor powder, and the glass matrix. Mercury concentration in the three phases was determined by the method known as cold vapor atomic absorption spectrometry. Median values obtained in the study showed that a compact fluorescent lamp contained 24.52±0.4ppb of mercury in the vapor phase, 204.16±8.9ppb of mercury in the phosphor powder, and 18.74±0.5ppb of mercury in the glass matrix. There are differences in mercury concentration between the lamps since the year of manufacture or the hours of operation affect both mercury content and its distribution. The 85.76% of the mercury introduced into a compact fluorescent lamp becomes a component of the phosphor powder, while more than 13.66% is diffused through the glass matrix. By washing and eliminating all phosphor powder attached to the glass surface it is possible to classified the glass as a non-hazardous waste.

  5. Pressure broadening of atomic oxygen two-photon absorption laser induced fluorescence

    NASA Astrophysics Data System (ADS)

    Marinov, Daniil; Drag, Cyril; Blondel, Christophe; Guaitella, Olivier; Golda, Judith; Klarenaar, Bart; Engeln, Richard; Schulz-von der Gathen, Volker; Booth, Jean-Paul

    2016-12-01

    Atomic oxygen, considered to be a determining reactant in plasma applications at ambient pressure, is routinely detected by two-photon absorption laser induced fluorescence (TALIF). Here, pressure broadening of the (2p 4 3 P 2  →  3p 3 P J=0,1,2) two-photon transition in oxygen atoms was investigated using a high-resolution TALIF technique in normal and Doppler-free configurations. The pressure broadening coefficients determined were {γ{{\\text{O}2}}}   =  0.40  ±  0.08  cm-1/bar for oxygen molecules and {γ\\text{He}}   =  0.46  ±  0.03 cm-1/bar for helium atoms. These correspond to pressure broadening rate constants k\\text{PB}{{\\text{O}2}}   =  9 · 10-9 cm3 s-1 and k\\text{PB}\\text{He}   =  4 · 10-9 cm3 s-1, respectively. The well-known quenching rate constants of O(3p 3 P J ) by O2 and He are at least one order of magnitude smaller, which signifies that non-quenching collisions constitute the main line-broadening mechanism. In addition to providing new insights into collisional processes of oxygen atoms in electronically excited 3p 3 P J state, reported pressure broadening parameters are important for quantification of oxygen TALIF line profiles when both collisional and Doppler broadening mechanisms are important. Thus, the Doppler component (and hence the temperature of oxygen atoms) can be accurately determined from high resolution TALIF measurements in a broad range of conditions.

  6. Determination of mercury distribution inside spent compact fluorescent lamps by atomic absorption spectrometry

    SciTech Connect

    Rey-Raap, Natalia

    2012-05-15

    Highlights: Black-Right-Pointing-Pointer New treatments for CFL are required considering the aim of Directive 202/96/CE. Black-Right-Pointing-Pointer It is shown that most of the mercury introduced into a CFL is in the phosphor powder. Black-Right-Pointing-Pointer Experimental conditions for microwave-assisted sample digestion followed by AAS measurements are described. Black-Right-Pointing-Pointer By washing the glass it is possible to reduce the concentration below legal limits. - Abstract: In this study, spent compact fluorescent lamps were characterized to determine the distribution of mercury. The procedure used in this research allowed mercury to be extracted in the vapor phase, from the phosphor powder, and the glass matrix. Mercury concentration in the three phases was determined by the method known as cold vapor atomic absorption spectrometry. Median values obtained in the study showed that a compact fluorescent lamp contained 24.52 {+-} 0.4 ppb of mercury in the vapor phase, 204.16 {+-} 8.9 ppb of mercury in the phosphor powder, and 18.74 {+-} 0.5 ppb of mercury in the glass matrix. There are differences in mercury concentration between the lamps since the year of manufacture or the hours of operation affect both mercury content and its distribution. The 85.76% of the mercury introduced into a compact fluorescent lamp becomes a component of the phosphor powder, while more than 13.66% is diffused through the glass matrix. By washing and eliminating all phosphor powder attached to the glass surface it is possible to classified the glass as a non-hazardous waste.

  7. New Homogeneous Standards by Atomic Layer Deposition for Synchrotron X-ray Fluorescence and Absorption Spectroscopies.

    SciTech Connect

    Butterworth, A.L.; Becker, N.; Gainsforth, Z.; Lanzirotti, A.; Newville, M.; Proslier, T.; Stodolna, J.; Sutton, S.; Tyliszczak, T.; Westphal, A.J.; Zasadzinski, J.

    2012-03-13

    Quantification of synchrotron XRF analyses is typically done through comparisons with measurements on the NIST SRM 1832/1833 thin film standards. Unfortunately, these standards are inhomogeneous on small scales at the tens of percent level. We are synthesizing new homogeneous multilayer standards using the Atomic Layer Deposition technique and characterizing them using multiple analytical methods, including ellipsometry, Rutherford Back Scattering at Evans Analytical, Synchrotron X-ray Fluorescence (SXRF) at Advanced Photon Source (APS) Beamline 13-ID, Synchrotron X-ray Absorption Spectroscopy (XAS) at Advanced Light Source (ALS) Beamlines 11.0.2 and 5.3.2.1 and by electron microscopy techniques. Our motivation for developing much-needed cross-calibration of synchrotron techniques is borne from coordinated analyses of particles captured in the aerogel of the NASA Stardust Interstellar Dust Collector (SIDC). The Stardust Interstellar Dust Preliminary Examination (ISPE) team have characterized three sub-nanogram, {approx}1{micro}m-sized fragments considered as candidates to be the first contemporary interstellar dust ever collected, based on their chemistries and trajectories. The candidates were analyzed in small wedges of aerogel in which they were extracted from the larger collector, using high sensitivity, high spatial resolution >3 keV synchrotron x-ray fluorescence spectroscopy (SXRF) and <2 keV synchrotron x-ray transmission microscopy (STXM) during Stardust ISPE. The ISPE synchrotron techniques have complementary capabilities. Hard X-ray SXRF is sensitive to sub-fg mass of elements Z {ge} 20 (calcium) and has a spatial resolution as low as 90nm. X-ray Diffraction data were collected simultaneously with SXRF data. Soft X-ray STXM at ALS beamline 11.0.2 can detect fg-mass of most elements, including cosmochemically important oxygen, magnesium, aluminum and silicon, which are invisible to SXRF in this application. ALS beamline 11.0.2 has spatial resolution

  8. Fluorescence detection of white-beam X-ray absorption anisotropy: towards element-sensitive projections of local atomic structure

    PubMed Central

    Korecki, P.; Tolkiehn, M.; Dąbrowski, K. M.; Novikov, D. V.

    2011-01-01

    Projections of the atomic structure around Nb atoms in a LiNbO3 single crystal were obtained from a white-beam X-ray absorption anisotropy (XAA) pattern detected using Nb K fluorescence. This kind of anisotropy results from the interference of X-rays inside a sample and, owing to the short coherence length of a white beam, is visible only at small angles around interatomic directions. Consequently, the main features of the recorded XAA corresponded to distorted real-space projections of dense-packed atomic planes and atomic rows. A quantitative analysis of XAA was carried out using a wavelet transform and allowed well resolved projections of Nb atoms to be obtained up to distances of 10 Å. The signal of nearest O atoms was detected indirectly by a comparison with model calculations. The measurement of white-beam XAA using characteristic radiation indicates the possibility of obtaining element-sensitive projections of the local atomic structure in more complex samples. PMID:21997909

  9. Mercury in Environmental and Biological Samples Using Online Combustion with Sequential Atomic Absorption and Fluorescence Measurements: A Direct Comparison of Two Fundamental Techniques in Spectrometry

    ERIC Educational Resources Information Center

    Cizdziel, James V.

    2011-01-01

    In this laboratory experiment, students quantitatively determine the concentration of an element (mercury) in an environmental or biological sample while comparing and contrasting the fundamental techniques of atomic absorption spectrometry (AAS) and atomic fluorescence spectrometry (AFS). A mercury analyzer based on sample combustion,…

  10. Calcium in the developing Ambystoma neural axis shown by 3H and fluorescent chlortetracycline and atomic absorption spectrometry

    SciTech Connect

    Moran, D.J. )

    1990-12-01

    The calcium ion has been implicated in the mediation of the morphogenetic movements that occur during neural tube formation. The present study identifies high levels of calcium in the neuroepithelium of the neural plate, folds, and tube. These levels are substantially higher than those discerned elsewhere in the embryo. The calcium is localized in morphogenetically active regions by using the antibiotic chlortetracycline (CTC) which chelates calcium and is demonstrated in this investigation by both autoradiography and calcium-linked fluorescence. The specificity of CTC reaction for calcium in the developing neural axis is confirmed by EGTA competition. A comparison of the actual calcium levels in the developing neural axis (dorsal) with equivalently weighted ventral tissues was obtained by atomic absorption spectrometry (AAS). This method provides a total count of the calcium without any loss during tissue processing. For AAS, living tissues were precisely excised and immediately dessicated. Each tissue sample (dry weight 1.5 mg) was then solubilized for analysis. The spectrometric data reveal that the embryonic dorsal aspect forming the neural tube contains 57% more calcium than an equivalent weight of the ventral aspect.

  11. Two-photon absorption laser induced fluorescence measurement of atomic oxygen density in an air atmospheric pressure plasma jet

    NASA Astrophysics Data System (ADS)

    Conway, Jim; Gogna, Gurusharan; Daniels, Stephen

    2016-09-01

    Two-photon Absorption Laser Induced Fluorescence (TALIF) is used to measure atomic oxygen number density [O] in an air Atmospheric Pressure Plasma Jet (APPJ). A novel technique based on photolysis of O2 is used to calibrate the TALIF system ensuring the same species (O) is probed during calibration and measurement. As a result, laser intensity can be increased outside the TALIF quadratic laser power region without affecting calibration reliability as any high intensity saturation effects will be identical for calibration and experiment. Higher laser intensity gives stronger TALIF signals helping overcome weak TALIF signals often experienced at atmospheric pressure due to collisional quenching. O2 photo-dissociation and two-photon excitation of the resulting [O] are both achieved within the same laser pulse. The photolysis [O] is spatially non-uniform and time varying. To allow valid comparison with [O] in a plasma, spatial and temporal correction factors are required. Knowledge of the laser pulse intensity I0(t), and wavelength allows correction factors to be found using a rate equation model. The air flow into the jet was fixed and the RF power coupled into the system varied. The resulting [O] was found to increase with RF power.

  12. Do Atoms Really "Emit" Absorption Lines?

    ERIC Educational Resources Information Center

    Brecher, Kenneth

    1991-01-01

    Presents three absorption line sources that enhance student understanding of the phenomena associated with the interaction of light with matter and help dispel the misconception that atoms "emit" absorption lines. Sources include neodymium, food coloring and other common household liquids, and fluorescent materials. (MDH)

  13. Mercury speciation in hair by headspace injection-gas chromatography-atomic fluorescence spectrometry (methylmercury) and combustion-atomic absorption spectrometry (total Hg).

    PubMed

    Gao, Y; De Galan, S; De Brauwere, A; Baeyens, W; Leermakers, M

    2010-10-15

    The speciation of Hg in human hair was carried out with combustion-atomic absorption spectrometry for total Hg (THg) and headspace-gas chromatography-atomic fluorescence spectrometry (HS-GC-AFS) for methylmercury (MMHg). The determination of total Hg in hair was carried out with the AMA analyzer (Advanced Mercury Analyser 254). Accuracy and reproducibility were assessed on a Certified Reference hair sample (IAEA-086 CRM), yielding, respectively, a recovery of 97.5% and a RSD of 3.2%. Analyses of 10 blank measurements resulted in a detection limit of 1.5 ng g(-1) of THg for a 20mg sample of human hair. MMHg concentrations in hair were assessed with HS-GC-AFS in a single analysis step. Either acid or alkaline extraction can be applied because they yielded very similar results on a IAEA-086 CRM: we observed a recovery of 103% and a RSD of 7% with acid extraction and a recovery of 110% and a RSD of 9% with alkaline extraction. Optimization of the headspace vial, injection and GC parameters is described. The detection limit of the MMHg determination in human hair, which amounts to 0.04 ng g(-1) for a 20mg sample, is far below the concentrations observed in natural samples. The number of samples that can be analyzed per hour, respectively, amounts to 8 for THg and 4 for MMHg. Finally, Hg speciation in natural human hair samples was carried out by combining both AMA and HS-GC-AFS analysis methods. THg levels were at the μg g(-1), level, with an average MMHg fraction of about 70%.

  14. Determination of subnanogram per cubic meter concentrations of metals in the air of a trace metal clean room by impaction graphite furnace atomic absorption and laser excited atomic fluorescence spectrometry.

    PubMed

    Liang, Z W; Wei, G T; Irwin, R L; Walton, A P; Michel, R G; Sneddon, J

    1990-07-15

    Air, drawn by vacuum through a jet, was impacted against the inside surface of an atomic absorption graphite electrothermal atomizer (ETA). The amounts of the particles thus collected were determined at the ng m-3 level by graphite furnace atomic absorption or at the pg m-3 level by laser excited atomic fluorescence. The overall reproducibility of two sets of measurements, made 7 months apart, was 23%, with no significant difference between the two sets of data, based on Student's "t" test at the 95% confidence level. Short-term reproducibility varied from 13% to 34% depending upon the air concentration of the metal. The method shows promise for monitoring long-term effectiveness of the filtering systems in trace metal clean rooms. It was not possible to test for accuracy, due to the low concentrations involved, but accuracy was expected to be within a factor of 2 or 3 of the actual value, based on theoretical aspects of impaction.

  15. Graphite filter atomizer in atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Katskov, Dmitri A.

    2007-09-01

    Graphite filter atomizers (GFA) for electrothermal atomic absorption spectrometry (ETAAS) show substantial advantages over commonly employed electrothermal vaporizers and atomizers, tube and platform furnaces, for direct determination of high and medium volatility elements in matrices associated with strong spectral and chemical interferences. Two factors provide lower limits of detection and shorter determination cycles with the GFA: the vaporization area in the GFA is separated from the absorption volume by a porous graphite partition; the sample is distributed over a large surface of a collector in the vaporization area. These factors convert the GFA into an efficient chemical reactor. The research concerning the GFA concept, technique and analytical methodology, carried out mainly in the author's laboratory in Russia and South Africa, is reviewed. Examples of analytical applications of the GFA in AAS for analysis of organic liquids and slurries, bio-samples and food products are given. Future prospects for the GFA are discussed in connection with analyses by fast multi-element AAS.

  16. Absolute atomic oxygen density measurements for nanosecond-pulsed atmospheric-pressure plasma jets using two-photon absorption laser-induced fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Jiang, C.; Carter, C.

    2014-12-01

    Nanosecond-pulsed plasma jets that are generated under ambient air conditions and free from confinement of electrodes have become of great interest in recent years due to their promising applications in medicine and dentistry. Reactive oxygen species that are generated by nanosecond-pulsed, room-temperature non-equilibrium He-O2 plasma jets among others are believed to play an important role during the bactericidal or sterilization processes. We report here absolute measurements of atomic oxygen density in a 1 mm-diameter He/(1%)O2 plasma jet at atmospheric pressure using two-photon absorption laser-induced fluorescence spectroscopy. Oxygen number density on the order of 1013 cm-3 was obtained in a 150 ns, 6 kV single-pulsed plasma jet for an axial distance up to 5 mm above the device nozzle. Temporally resolved O density measurements showed that there are two maxima, separated in time by 60-70 µs, and a total pulse duration of 260-300 µs. Electrostatic modeling indicated that there are high-electric-field regions near the nozzle exit that may be responsible for the observed temporal behavior of the O production. Both the field-distribution-based estimation of the time interval for the O number density profile and a pulse-energy-dependence study confirmed that electric-field-dependent, direct and indirect electron-induced processes play important roles for O production.

  17. Femtosecond, two-photon-absorption, laser-induced-fluorescence (fs-TALIF) imaging of atomic hydrogen and oxygen in non-equilibrium plasmas

    NASA Astrophysics Data System (ADS)

    Schmidt, Jacob B.; Roy, Sukesh; Kulatilaka, Waruna D.; Shkurenkov, Ivan; Adamovich, Igor V.; Lempert, Walter R.; Gord, James R.

    2017-01-01

    Femtosecond, two-photon-absorption laser-induced fluorescence (fs-TALIF) is employed to measure space- and time-resolved distributions of atomic hydrogen and oxygen in moderate-pressure, non-equilibrium, nanosecond-duration pulsed-discharge plasmas. Temporally and spatially resolved hydrogen and oxygen TALIF images are obtained over a range of low-temperature plasmas in mixtures of helium and argon at 100 Torr total pressure. The high-peak-intensity, low-average-energy fs pulses combined with the increased spectral bandwidth compared to traditional ns-duration laser pulses provide a large number of photon pairs that are responsible for the two-photon excitation, which results in an enhanced TALIF signal. Krypton and xenon TALIF are used for quantitative calibration of the hydrogen and oxygen concentrations, respectively, with similar excitation schemes being employed. This enables 2D collection of atomic-hydrogen and -oxygen TALIF signals with absolute number densities ranging from 2  ×  1012 cm-3 to 6  ×  1015 cm-3 and 1  ×  1013 cm-3 to 3  ×  1016 cm-3, respectively. These 2D images are the first application of TALIF imaging in moderate-pressure plasma discharges. 1D self-consistent modeling predictions show agreement with experimental results within the estimated experimental error of 25%. The present results can be used to further the development of higher fidelity kinetic models while quantifying plasma-source characteristics.

  18. Determination of Fe(II) and Fe(III) in small samples by microbore ion chromatography and photometric, atomic absorption spectrometry and total-reflection X-ray fluorescence detection

    NASA Astrophysics Data System (ADS)

    Sinner, T.; Hoffmann, P.; Ortner, H. M.

    1993-02-01

    Iron(II) and iron(III) are determined after separation on an ion Chromatographie column by various detection systems. "On-line" detection was achieved by the use of a photometer with a flow cell of 0.8 μl; for "off-line" detection, graphite furnace atomic absorption spectrometry or total-reflection X-ray fluorescence were used. The applicability of the methods is shown for standard solutions and atmospheric samples. As a typical result, 50 μg/l of iron can be determined in a 10 μl sample with a nucrobore ion chromatograph-photometer and atomic absorption system and 40 μg/l of iron in a microbore ion chromatograph-total-reflection X-ray fluorescence combination.

  19. Atomic absorption spectroscopy in ion channel screening.

    PubMed

    Stankovich, Larisa; Wicks, David; Despotovski, Sasko; Liang, Dong

    2004-10-01

    This article examines the utility of atomic absorption spectroscopy, in conjunction with cold flux assays, to ion channel screening. The multiplicity of ion channels that can be interrogated using cold flux assays and atomic absorption spectroscopy is summarized. The importance of atomic absorption spectroscopy as a screening tool is further elaborated upon by providing examples of the relevance of ion channels to various physiological processes and targeted diseases.

  20. Absorption imaging of a single atom

    NASA Astrophysics Data System (ADS)

    Streed, Erik W.; Jechow, Andreas; Norton, Benjamin G.; Kielpinski, David

    2012-07-01

    Absorption imaging has played a key role in the advancement of science from van Leeuwenhoek's discovery of red blood cells to modern observations of dust clouds in stellar nebulas and Bose-Einstein condensates. Here we show the first absorption imaging of a single atom isolated in a vacuum. The optical properties of atoms are thoroughly understood, so a single atom is an ideal system for testing the limits of absorption imaging. A single atomic ion was confined in an RF Paul trap and the absorption imaged at near wavelength resolution with a phase Fresnel lens. The observed image contrast of 3.1 (3)% is the maximum theoretically allowed for the imaging resolution of our set-up. The absorption of photons by single atoms is of immediate interest for quantum information processing. Our results also point out new opportunities in imaging of light-sensitive samples both in the optical and X-ray regimes.

  1. Absorption imaging of a single atom.

    PubMed

    Streed, Erik W; Jechow, Andreas; Norton, Benjamin G; Kielpinski, David

    2012-07-03

    Absorption imaging has played a key role in the advancement of science from van Leeuwenhoek's discovery of red blood cells to modern observations of dust clouds in stellar nebulas and Bose-Einstein condensates. Here we show the first absorption imaging of a single atom isolated in a vacuum. The optical properties of atoms are thoroughly understood, so a single atom is an ideal system for testing the limits of absorption imaging. A single atomic ion was confined in an RF Paul trap and the absorption imaged at near wavelength resolution with a phase Fresnel lens. The observed image contrast of 3.1 (3)% is the maximum theoretically allowed for the imaging resolution of our set-up. The absorption of photons by single atoms is of immediate interest for quantum information processing. Our results also point out new opportunities in imaging of light-sensitive samples both in the optical and X-ray regimes.

  2. Optimized absorption imaging of mesoscopic atomic clouds

    NASA Astrophysics Data System (ADS)

    Muessel, Wolfgang; Strobel, Helmut; Joos, Maxime; Nicklas, Eike; Stroescu, Ion; Tomkovič, Jiří; Hume, David B.; Oberthaler, Markus K.

    2013-10-01

    We report on the optimization of high-intensity absorption imaging for small Bose-Einstein condensates. The imaging calibration exploits the linear scaling of the quantum projection noise with the mean number of atoms for a coherent spin state. After optimization for atomic clouds containing up to 300 atoms, we find an atom number resolution of atoms, mainly limited by photon shot noise and radiation pressure.

  3. Microdroplet Sample Application in Electrothermal Atomization for Atomic Absorption Spectrometry.

    DTIC Science & Technology

    1982-03-29

    ad ideftify by Week amber) atomic absorption spectroscopy microsampl ing graphite- furnace AAS automation C> 20. AOSTRACT (Coninuhe an reveresi de It...furnace and spectrometer system as well as for partial support of this project. REFERENCES 1. J. D. Winefordner, Atomic Absorption Spectroscopy , G. F

  4. Containerless Atomic-Fluorescence Property Measurements

    NASA Technical Reports Server (NTRS)

    Nordine, P.; Schiffman, R.; Walker, C.

    1987-01-01

    Report describes studies conducted to establish and verify use of laser-induced fluorescence in monitoring and controlling high-temperature containerless processes. Specimens levitated by gas jets or electromagnetic fields and heated by laser beams or electromagnetic induction while being irradiated and detected by fluorescence technique. Makes quantitative and qualitative comparisons among three new methods of temperature measurement; all rely on laser-induced fluorescence. One method gas-density thermometry with seed gas. Other two methods involve measurements of velocities of evaporating atoms or of population ratios of different electronic states.

  5. Absorption and fluorescent spectral studies of imidazophenazine derivatives

    NASA Astrophysics Data System (ADS)

    Ryazanova, O. A.; Zozulya, V. N.; Voloshin, I. M.; Karachevtsev, V. A.; Makitruk, V. L.; Stepanian, S. G.

    2004-07-01

    Absorption and fluorescent spectra as well as fluorescence polarization degree of imidazo-[4,5-d]-phenazine (F1) and its two modified derivatives, 2-trifluoridemethylimidazo-[4,5-d]-phenazine (F2) and 1,2,3-triazole-[4,5-d]-phenazine (F3), were investigated in organic solvents of various polarities and hydrogen bonding abilities. Extinction coefficients of F2 and F3 are increased, their fluorescence Stokes shifts are reduced in comparison with those for unmodified imidazophenazine. For F3 a red shift of the longwave absorption band is observed by 15-20 nm. Modifications of imidazophenazine have led to a sufficient increase of fluorescence polarization degrees that enables to use F2 and F3 as promising fluorescent probes with polarization method application. The configuration, atomic charge distribution and dipole moments of the isolated dye molecules in the ground state were calculated by the DFT method. The computation has revealed that ground state dipole moments of F1, F2, and F3 differ slightly and are equal to 3.5, 3.2, and 3.7 D, respectively. The changes in dipole moments upon the optical excitation for all derivatives estimated using Lippert equation were found to be Δ μ=9 D. The energies of the electronic S 1←S 0 transition in solvents of different proton donor abilities were determined, and energetic diagram illustrating the substituent effect was plotted. For nucleoside analogs of these compounds, covalently incorporated into a nucleotide chain, we have considered a possibility to use them as fluorescent reporters of hybridization of antisense oligonucleotides, as well as molecular anchors for its stabilization.

  6. Two-photon-excited fluorescence spectroscopy of atomic fluorine at 170 nm

    NASA Technical Reports Server (NTRS)

    Herring, G. C.; Dyer, Mark J.; Jusinski, Leonard E.; Bischel, William K.

    1988-01-01

    Two-photon-excited fluorescence spectroscopy of atomic fluorine is reported. A doubled dye laser at 286-nm is Raman shifted in H2 to 170 nm (sixth anti-Stokes order) to excite ground-state 2P(0)J fluorine atoms to the 2D(0)J level. The fluorine atoms are detected by one of two methods: observing the fluorescence decay to the 2PJ level or observing F(+) production through the absorption of an additional photon by the excited atoms. Relative two-photon absorption cross sections to and the radiative lifetimes of the 2D(0)J states are measured.

  7. Analysis of cement by atomic absorption spectrophotometry and volumetric method.

    PubMed

    Choi, K K; Lam, L; Luk, S F

    1994-01-01

    A new method to determine the composition of cement raw mix and cement is devised. The sample was fused with a mixture of sodium carbonate and lithium tetraborate (3:1) at 925 degrees C for 10 min. The fusion cake was dissolved in hydrochloric acid. The concentration of analyte in solution was either determined by atomic absorption spectrophotometry or titrimetry. The proposed method is quick and the analysis for interested oxides (SiO(2), Al(2)O(3), Fe(2)O(3), and CaO) can be completed within 1 hr. The accuracy and precision are comparable to that of X-ray fluorescence spectrometry.

  8. Continuum Absorption Coefficient of Atoms and Ions

    NASA Technical Reports Server (NTRS)

    Armaly, B. F.

    1979-01-01

    The rate of heat transfer to the heat shield of a Jupiter probe has been estimated to be one order of magnitude higher than any previously experienced in an outer space exploration program. More than one-third of this heat load is due to an emission of continuum radiation from atoms and ions. The existing computer code for calculating the continuum contribution to the total load utilizes a modified version of Biberman's approximate method. The continuum radiation absorption cross sections of a C - H - O - N ablation system were examined in detail. The present computer code was evaluated and updated by being compared with available exact and approximate calculations and correlations of experimental data. A detailed calculation procedure, which can be applied to other atomic species, is presented. The approximate correlations can be made to agree with the available exact and experimental data.

  9. Flameless Atomic Absorption Spectrophotometric Analysis for Lewisite (L).

    DTIC Science & Technology

    1978-10-01

    method that was developed for detection of Lewisite by analysis for arsenic, using flameless atomic absorption spectroscopy (FAAS). “Flameless atomic ...place in a furnace, and the flame associated with con- ventional atomic absorption spectroscopy is not needed. The procedure that was used is given along...nickel was unnecessary for the Lewisite samples. Table 1. Flameless atomic absorption spectroscopy conditions used for determination of arsenic in

  10. 2. VIEW IN ROOM 111, ATOMIC ABSORPTION BERYLLIUM ANALYSIS LABORATORY. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW IN ROOM 111, ATOMIC ABSORPTION BERYLLIUM ANALYSIS LABORATORY. AIR FILTERS AND SWIPES ARE DISSOLVED WITH ACIDS AND THE REMAINING RESIDUES ARE SUSPENDED IN NITRIC ACID SOLUTION. THE SOLUTION IS PROCESSED THROUGH THE ATOMIC ABSORPTION SPECTROPHOTOMETER TO DETECT THE PRESENCE AND LEVELS OF BERYLLIUM. - Rocky Flats Plant, Health Physics Laboratory, On Central Avenue between Third & Fourth Streets, Golden, Jefferson County, CO

  11. [Digestion-flame atomic absorption spectroscopy].

    PubMed

    Xu, Liang; Hu, Jian-Guo; Liu, Rui-Ping; Wang, Zhi-Min; Narenhua

    2008-01-01

    A microwave digestion-flame atomic absorption spectroscopy (FAAS) method was developed for the determination of metal elements Na, Zn, Cu, Fe, Mn, Ca and Mg in Mongolian patents. The instrument parameters for the determination were optimized, and the appropriate digestion solvent was selected. The recovery of the method was between 95.8% and 104.3%, and the RSD was between 1.6% and 4.2%. The accuracy and precision of the method was tested by comparing the values obtained from the determination of the standard sample, bush twigs and leaves (GSV-1) by this method with the reference values of GSV-1. The determination results were found to be basically consistent with the reference values. The microwave digestion technique was applied to process the samples, and the experimental results showed that compared to the traditional wet method, the present method has the merits of simplicity, saving agents, rapidness, and non-polluting. The method was accurate and reliable, and could be used to determine the contents of seven kinds of metal elements in mongolian patents.

  12. Flameless atomic-absorption determination of gold in geological materials

    USGS Publications Warehouse

    Meier, A.L.

    1980-01-01

    Gold in geologic material is dissolved using a solution of hydrobromic acid and bromine, extracted with methyl isobutyl ketone, and determined using an atomic-absorption spectrophotometer equipped with a graphite furnace atomizer. A comparison of results obtained by this flameless atomic-absorption method on U.S. Geological Survey reference rocks and geochemical samples with reported values and with results obtained by flame atomic-absorption shows that reasonable accuracy is achieved with improved precision. The sensitivity, accuracy, and precision of the method allows acquisition of data on the distribution of gold at or below its crustal abundance. ?? 1980.

  13. Absorption Reconstruction Improves Biodistribution Assessment of Fluorescent Nanoprobes Using Hybrid Fluorescence-mediated Tomography

    PubMed Central

    Gremse, Felix; Theek, Benjamin; Kunjachan, Sijumon; Lederle, Wiltrud; Pardo, Alessa; Barth, Stefan; Lammers, Twan; Naumann, Uwe; Kiessling, Fabian

    2014-01-01

    Aim: Fluorescence-mediated tomography (FMT) holds potential for accelerating diagnostic and theranostic drug development. However, for proper quantitative fluorescence reconstruction, knowledge on optical scattering and absorption, which are highly heterogeneous in different (mouse) tissues, is required. We here describe methods to assess these parameters using co-registered micro Computed Tomography (µCT) data and nonlinear whole-animal absorption reconstruction, and evaluate their importance for assessment of the biodistribution and target site accumulation of fluorophore-labeled drug delivery systems. Methods: Besides phantoms with varying degrees of absorption, mice bearing A431 tumors were imaged 15 min and 48 h after i.v. injection of a fluorophore-labeled polymeric drug carrier (pHPMA-Dy750) using µCT-FMT. The outer shape of mice and a scattering map were derived using automated segmentation of the µCT data. Furthermore, a 3D absorption map was reconstructed from the trans-illumination data. We determined the absorption of five interactively segmented regions (heart, liver, kidney, muscle, tumor). Since blood is the main near-infrared absorber in vivo, the absorption was also estimated from the relative blood volume (rBV), determined by contrast-enhanced µCT. We compared the reconstructed absorption with the rBV-based values and analyzed the effect of using the absorption map on the fluorescence reconstruction. Results: Phantom experiments demonstrated that absorption reconstruction is possible and necessary for quantitative fluorescence reconstruction. In vivo, the reconstructed absorption showed high values in strongly blood-perfused organs such as the heart, liver and kidney. The absorption values correlated strongly with the rBV-based absorption values, confirming the accuracy of the absorption reconstruction. Usage of homogenous absorption instead of the reconstructed absorption map resulted in reduced values in the heart, liver and kidney, by

  14. Determination of iridium in mafic rocks by atomic absorption

    USGS Publications Warehouse

    Grimaldi, F.S.; Schnepfe, M.M.

    1970-01-01

    Iridium is determined in mineralized mafic rocks by atomic absorption after fire-assay concentration into a gold bead. Interelement interferences in the atomic-absorption determination are removed and Ir sensitivity is increased by buffering the solutions with a mixture of copper and sodium sulphates. Substantial amounts of Ag, Al, Au, Bi, Ca, Cd, Co, Cr, Fe, Ho, Hg, K, La, Mg, Mn, Mo, Ni, Pb, Te, Ti, V, Y, Zn and platinum metals can be tolerated in the atomic-absorption determination. The sensitivity and detection limits are 3.2 and 0.25 ppm of Ir, respectively. ?? 1970.

  15. Two-photon absorption properties of fluorescent proteins

    PubMed Central

    Drobizhev, Mikhail; Makarov, Nikolay S.; Tillo, Shane E.; Hughes, Thomas E.; Rebane, Aleksander

    2016-01-01

    Two-photon excitation of fluorescent proteins is an attractive approach for imaging living systems. Today researchers are eager to know which proteins are the brightest, and what the best excitation wavelengths are. Here we review the two-photon absorption properties of a wide variety of fluorescent proteins, including new far-red variants, to produce a comprehensive guide to choosing the right FP and excitation wavelength for two-photon applications. PMID:21527931

  16. Recent developments in atomizers for electrothermal atomic absorption spectrometry.

    PubMed

    Frech, W

    1996-06-01

    This review first describes general requirements to be met for suitable base materials used to produce electrothermal atomizers (ETAs). In this connection the physical and chemical properties of adequate types of graphite and metals are discussed. Further, various atomizer designs, their temperature dynamics during atomization and general performance characteristics are critically reviewed. For end-heated Massmann-type atomizers, discussions are focused on recent developments of, e.g., contoured tubes to achieve improved temperature homogeneity over the tube length, second surface atomizers to realize temporally isothermal atomization and tubes with graphite filters to reduce interference effects. The state-of-the-art of platform equipped, side-heated atomizers with integrated contacting bridges are characterized mainly with respect to heating dynamics, as well as susceptibility to interference- and memory effects. In contrast to end-heated ETAs, the tube ends of side-heated ETAs are freely located in the furnace compartment and, as a consequence of this configuration, convective gas flows can easily appear. The magnitude and effect of these flows on analytical performance are discussed and measures are suggested, permitting operation under diffusion controlled conditions. A critical comparison of classical constant temperature atomizers with state-of-the-art platform equipped ETAs is made and from this it is concluded that future ETA developments are likely to involve only minor modifications aiming at, e.g., the reduction of cycling times or the improvement of tube surface properties.

  17. Atomic fluorescence study of high temperature aerodynamic levitation

    NASA Technical Reports Server (NTRS)

    Nordine, P. C.; Schiffman, R. A.; Sethi, D. S.

    1982-01-01

    Ultraviolet laser induced atomic fluorescence has been used to characterize supersonic jet aerodynamic levitation experiments. The levitated specimen was a 0.4 cm sapphire sphere that was separately heated at temperatures up to 2327 K by an infrared laser. The supersonic jet expansion and thermal gradients in the specimen wake were studied by measuring spatial variations in the concentration of atomic Hg added to the levitating argon gas stream. Further applications of atomic fluorescence in containerless experiments, such as ideal gas fluorescence thermometry and containerless process control are discussed.

  18. Visualizing the Solute Vaporization Interference in Flame Atomic Absorption Spectroscopy

    ERIC Educational Resources Information Center

    Dockery, Christopher R.; Blew, Michael J.; Goode, Scott R.

    2008-01-01

    Every day, tens of thousands of chemists use analytical atomic spectroscopy in their work, often without knowledge of possible interferences. We present a unique approach to study these interferences by using modern response surface methods to visualize an interference in which aluminum depresses the calcium atomic absorption signal. Calcium…

  19. Containerless high temperature property measurements by atomic fluorescence

    NASA Technical Reports Server (NTRS)

    Nordine, P. C.; Schiffman, R. A.

    1982-01-01

    Laser induced fluorescence techniques were developed for the containerless study of high temperature processes, material properties, levitation, and heating techniques for containerless earth-based experimentation. Experiments were performed in which fluorescence of atomic aluminum, mercury, or tungsten were studied. These experiments include measurements of: (1) Al atom evaporation from CW CO2 laser heated and aerodynamically levitated sapphire and alumina spheres, and self-supported sapphire filaments, (2) Al atom reaction with ambient oxygen in the wake of a levitated specimen, (3) Hg atom concentrations in the wake of levitated alumina and sapphire spheres, relative to the ambient Hg atom concentration, (4) Hg atom concentrations in supersonic levitation jets, and (5) metastable, electronically excited W atom concentrations produced by evaporation of an electrically heated tungsten filament.

  20. Resonance fluorescence from an atom in a squeezed vacuum

    NASA Astrophysics Data System (ADS)

    Carmichael, H. J.; Lane, A. S.; Walls, D. F.

    1987-06-01

    The fluorescent spectrum for a two-level atom which is damped by a squeezed vacuum shows striking differences from the spectrum for ordinary resonance fluorescence. For strong coherent driving fields the Mollow triplet depends on the relative phase of the driving field and the squeezed vacuum field. The central peak may have either subnatural linewidth or supernatural linewidth depending on this phase. The mean atomic polarization also shows a phase sensitivity.

  1. Perfect electromagnetic absorption at one-atom-thick scale

    SciTech Connect

    Li, Sucheng; Duan, Qian; Li, Shuo; Yin, Qiang; Lu, Weixin; Li, Liang; Hou, Bo; Gu, Bangming; Wen, Weijia

    2015-11-02

    We experimentally demonstrate that perfect electromagnetic absorption can be realized in the one-atom thick graphene. Employing coherent illumination in the waveguide system, the absorbance of the unpatterned graphene monolayer is observed to be greater than 94% over the microwave X-band, 7–13 GHz, and to achieve a full absorption, >99% in experiment, at ∼8.3 GHz. In addition, the absorption characteristic manifests equivalently a wide range of incident angle. The experimental results agree very well with the theoretical calculations. Our work accomplishes the broadband, wide-angle, high-performance absorption in the thinnest material with simple configuration.

  2. A fluorescent benzothiazole probe with efficient two-photon absorption

    NASA Astrophysics Data System (ADS)

    Echevarria, Lorenzo; Moreno, Iván; Camacho, José; Salazar, Mary Carmen; Hernández, Antonio

    2012-11-01

    In this work, we report the two-photon absorption of 2-[4-(dimethylamino)phenyl]-1,3-benzothiazole-6-carbonitrile (DBC) in DMSO solution pumping at 779 nm with a 10 ns pulse laser-Nd:YAG system. The obtained two-photon absorption cross-section in DBC (407 ± 18 GM) is considerably high. Because DBC is a novel compound and have high values of fluorescence quantum yield, this result is expected to have an impact in biomolecules detection, diagnosis and treatment of cancer. Similar structures have previously been reported to show remarkable antitumour effects.

  3. Principles and calibration of collinear photofragmentation and atomic absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Sorvajärvi, Tapio; Toivonen, Juha

    2014-06-01

    The kinetics of signal formation in collinear photofragmentation and atomic absorption spectroscopy (CPFAAS) are discussed, and theoretical equations describing the relation between the concentration of the target molecule and the detected atomic absorption in case of pure and impure samples are derived. The validity of the equation for pure samples is studied experimentally by comparing measured target molecule concentrations to concentrations determined using two other independent techniques. Our study shows that CPFAAS is capable of measuring target molecule concentrations from parts per billion (ppb) to hundreds of parts per million (ppm) in microsecond timescale. Moreover, the possibility to extend the dynamic range to cover eight orders of magnitude with a proper selection of fragmentation light source is discussed. The maximum deviation between the CPFAAS technique and a reference measurement technique is found to be less than 5 %. In this study, potassium chloride vapor and atomic potassium are used as a target molecule and a probed atom, respectively.

  4. Determination of palladium and platinum by atomic absorption

    USGS Publications Warehouse

    Schnepfe, M.M.; Grimaldi, F.S.

    1969-01-01

    Palladium and platinum are determined by atomic absorption after fire-assay concentration into a gold bead. The limit of determination is ~0??06 ppm in a 20-g sample. Serious depressive interelement interferences are removed by buffering the solutions with a mixture of cadmium and copper sulphates with cadmium and copper concentrations each at 0??5%. Substantial amounts of Ag, Al, Au, Bi, Ca, Co, Cr, Fe, Hg, K, La, Mg, Mn, Mo, Na, Ni, Pb, Te, Ti, V, Y, Zn, and the platinum metals do not interfere in the atomic-absorption determination. ?? 1969.

  5. Atomic-absorption determination of rhodium in chromite concentrates

    USGS Publications Warehouse

    Schnepfe, M.M.; Grimaldi, F.S.

    1969-01-01

    Rhodium is determined in chromite concentrates by atomic absorption after concentration either by co-precipitation with tellurium formed by the reduction of tellurite with tin(II) chloride or by fire assay into a gold bead. Interelement interferences in the atomic-absorption determination are removed by buffering the solutions with lanthanum sulphate (lanthanum concentration 1%). Substantial amounts of Ag, Al, Au, Bi, Ca, Cd, Co, Cr, Cu, Fe, Ho, Hg, K, La, Mg, Mn, Mo, Na, Ni, Pb, Te, Ti, V, Y, Zn and platinum metals can be tolerated. A lower limit of approximately 0.07 ppm Rh can be determined in a 3-g sample. ?? 1969.

  6. Speciation of mercury compounds by differential atomization - atomic absorption spectroscopy

    SciTech Connect

    Robinson, J.W.; Skelly, E.M.

    1982-01-01

    This paper describes the dual stage atomization technique which allows speciation of several mercury-containing compounds in aqueous solution and in biological fluids. The technique holds great promise for further speciation studies. Accurate temperature control, expecially at temperatures less than 200/sup 0/C, is needed to separate the extremely volatile mercury halides and simple organomercurials from each other. Studies with mercury salts and EDTA, L-cysteine and dithioxamide demonstrate that this technique may be used to study the extent of complex formation. Investigations of biological fluids indicate that there is a single predominant form of mercury in sweat and a single predominant form of mercury in urine. The mercury compound in urine is more volatile than that in sweat. Both quantitative and qualitative analyses are possible with this technique.

  7. Atomic Absorption Spectroscopy. The Present and the Future.

    ERIC Educational Resources Information Center

    Slavin, Walter

    1982-01-01

    The status of current techniques and methods of atomic absorption (AA) spectroscopy (flame, hybrid, and furnace AA) is discussed, including limitations. Technological opportunities and how they may be used in AA are also discussed, focusing on automation, microprocessors, continuum AA, hybrid analyses, and others. (Author/JN)

  8. Electrothermal atomic absorption determination of silver in cadmium selenide

    SciTech Connect

    Khozhainov, Y.M.; Deinikina, N.P.; Tyurin, O.A.

    1985-10-01

    The authors developed an atomic absorption method for determining trace silver in cadmium selenide, restricted to samples of 3 - 10 mg. Used as cp reagents, including those further purified, were distilled nitric acid, isothermally distilled hydrochloric acid, cadmium selenide, and S /SUB r/ grade silver with a purity of 99.999%.

  9. [Burner head with high sensitivity in atomic absorption spectroscopy].

    PubMed

    Feng, X; Yang, Y

    1998-12-01

    This paper presents a burner head with gas-sample separate entrance and double access, which is used for atomic absorption spectroscopy. According to comparison and detection, the device can improve sensitivity by a factor of 1 to 5. In the meantime it has properties of high stability and resistance to interference.

  10. Developing a Transdisciplinary Teaching Implement for Atomic Absorption Spectroscopy

    ERIC Educational Resources Information Center

    Drew, John

    2008-01-01

    In this article I explain why I wrote the set of teaching notes on Atomic Absorption Spectroscopy (AAS) and why they look the way they do. The notes were intended as a student reference to question, highlight and write over as much as they wish during an initial practical demonstration of the threshold concept being introduced, in this case…

  11. Precision atomic beam density characterization by diode laser absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Oxley, Paul; Wihbey, Joseph

    2016-09-01

    We provide experimental and theoretical details of a simple technique to determine absolute line-of-sight integrated atomic beam densities based on resonant laser absorption. In our experiments, a thermal lithium beam is chopped on and off while the frequency of a laser crossing the beam at right angles is scanned slowly across the resonance transition. A lock-in amplifier detects the laser absorption signal at the chop frequency from which the atomic density is determined. The accuracy of our experimental method is confirmed using the related technique of wavelength modulation spectroscopy. For beams which absorb of order 1% of the incident laser light, our measurements allow the beam density to be determined to an accuracy better than 5% and with a precision of 3% on a time scale of order 1 s. Fractional absorptions of order 10-5 are detectable on a one-minute time scale when we employ a double laser beam technique which limits laser intensity noise. For a lithium beam with a thickness of 9 mm, we have measured atomic densities as low as 5 × 104 atoms cm-3. The simplicity of our technique and the details we provide should allow our method to be easily implemented in most atomic or molecular beam apparatuses.

  12. [Investigation of enhancing effect for hydride generation-atomic fluorescence of transition metal elements].

    PubMed

    Sun, Han-Wen; Suo, Ran

    2008-11-01

    A mechanism of hydride generation based on disassembly reaction of hydrogen-transferred interim state [M(BH4)m]* was developed by investigating the effect of reaction medium acidity on hydride generation. The effects of Co2+ and Ni2+, phenanthroline and 8-hydroxyquinoline on hydride generation-atomic fluorescence signals of Zn, Cd, Cu and Ni were studied, respectively, and their enhancing mechnism was discussed. The enhancing effect Co2+ and Ni2+ on the fluorescence signals of Zn and Cd was due to the increase in transmission efficiency of hydride of Zn and Cd. There was a synergic enhancing effect between phenanthroline or 8-hydroxyquinoline and Co2+ on the fluorescence signals of Zn and Cd, however no synergic enhancing effect between phenanthroline and 8-hydroxyquinoline on the fluorescence signals of Zn and Cd. The simulative action of cationic surfactant, anion surfactant and non-ionic surfactant surfactant to hydride generation was investigated. It is shown that both cationic surfactant and non-ionic surfactant have obvious enhancing effect on the fluorescence signals of analytes because of the decrease in surface tension of reaction solution. The release characteristics of hydride from the absorption solution containing surfactant was ulteriorly examined by using graphite furnace atomic absorption spectrometry, and the mechanism of enhancing effect of surfactant on hydride generation and transmission was proposed.

  13. Velocity measurements by laser resonance fluorescence. [single atom diffusional motion

    NASA Technical Reports Server (NTRS)

    She, C. Y.; Fairbank, W. M., Jr.

    1980-01-01

    The photonburst correlation method was used to detect single atoms in a buffer gas. Real time flow velocity measurements with laser induced resonance fluorescence from single or multiple atoms was demonstrated and this method was investigated as a tool for wind tunnel flow measurement. Investigations show that single atoms and their real time diffusional motion on a buffer gas can be measured by resonance fluorescence. By averaging over many atoms, flow velocities up to 88 m/s were measured in a time of 0.5 sec. It is expected that higher flow speeds can be measured and that the measurement time can be reduced by a factor of 10 or more by careful experimental design. The method is clearly not ready for incorporation in high speed wind tunnels because it is not yet known whether the stray light level will be higher or lower, and it is not known what detection efficiency can be obtained in a wind tunnel situation.

  14. Laser-Induced Fluorescence Measurements for Optical Single Atom Detection for Nuclear Astrophysics

    NASA Astrophysics Data System (ADS)

    Parzuchowski, Kristen; Singh, Jaideep; Wenzl, Jennifer; Frisbie, Dustin; Johnson, Maegan

    2016-09-01

    We propose a new highly selective detector to measure rare nuclear reactions relevant for nuclear astrophysics. Our primary interest is the 22Ne(α , n) 25Mg reaction, which is a primary source of neutrons for the s-process. Our proposed detector, in conjunction with a recoil separator, captures the recoil products resulting from the reaction in a cryogenically frozen thin film of solid neon. The fluorescence spectra of the captured atoms is shifted from the absorption spectra by hundreds of nanometers. This allows for the optical detection of individual fluorescence photons against a background of intense excitation light. We will describe our initial studies of laser-induced fluorescence of Yb and Mg in solid Ne. Neon is an attractive medium because it is optically transparent and provides efficient, pure, stable, & chemically inert confinement for a wide variety of atomic and molecular species. Yb is used as a test atom because of its similar atomic structure to Mg and much brighter fluorescence signal. This work is supported by funds from Michigan State University.

  15. Determination of nanogram amounts of bismuth in rocks by atomic absorption spectrometry with electrothermal atomization

    USGS Publications Warehouse

    Kane, J.S.

    1979-01-01

    Bismuth concentrations as low as 10 ng g-1 in 100-mg samples of geological materials can be determined by atomic absorption spectrometry with electrothermal atomization. After HF-HClO4 decomposition of the sample, bismuth is extracted as the iodide into methyl isobutyl ketone and is then stripped with ethylenediaminetetraacetic acid into the aqueous phase. Aliquots of this solution are pipetted into the graphite furnace and dried, charred, and atomized in an automated sequence. Atomic absorbance at the Bi 223.1-nm line provides a measure of the amount of bismuth present. Results are presented for 14 U.S. Geological Survey standard rocks. ?? 1979.

  16. Imaging atoms from resonance fluorescence spectrum beyond the diffraction limit

    NASA Astrophysics Data System (ADS)

    Liao, Zeyang; Al-Amri, Mohammad; Zubairy, M. Suhail

    2014-03-01

    We calculate the resonance fluorescence spectrum of a linear chain of two-level atoms driven by a gradient coherent laser field. The result shows that we can determine the positions of atoms from the spectrum even when the atoms locate within subwavelength range and the dipole-dipole interaction is significant. This far-field resonance fluorescence localization microscopy method does not require point-by-point scanning and it may be more time-efficient. We also give a possible scheme to extract the position information in an extended region without requiring more peak power of laser. We also briefly discuss how to do a 2D imaging based on our scheme. This work is supported by grants from the King Abdulaziz City for Science and Technology (KACST) and the Qatar National Research Fund (QNRF) under the NPRP project.

  17. [Application of atomic absorption spectrometry in the engine knock detection].

    PubMed

    Chen, Li-Dan

    2013-02-01

    Because existing human experience diagnosis method and apparatus for auxiliary diagnosis method are difficult to diagnose quickly engine knock. Atomic absorption spectrometry was used to detect the automobile engine knock in in innovative way. After having determined Fe, Al, Cu, Cr and Pb content in the 35 groups of Audi A6 engine oil whose travel course is 2 000 -70 000 kilometers and whose sampling interval is 2 000 kilometers by atomic absorption spectrometry, the database of primary metal content in the same automobile engine at different mileage was established. The research shows that the main metal content fluctuates within a certain range. In practical engineering applications, after the determination of engine oil main metal content and comparison with its database value, it can not only help to diagnose the type and location of engine knock without the disintegration and reduce vehicle maintenance costs and improve the accuracy of engine knock fault diagnosis.

  18. Quantitative analysis of immobilized metalloenzymes by atomic absorption spectroscopy.

    PubMed

    Opwis, Klaus; Knittel, Dierk; Schollmeyer, Eckhard

    2004-12-01

    A new, sensitive assay for the quantitative determination of immobilized metal containing enzymes has been developed using atomic absorption spectroscopy (AAS). In contrast with conventionally used indirect methods the described quantitative AAS assay for metalloenzymes allows more exact analyses, because the carrier material with the enzyme is investigated directly. As an example, the validity and reliability of the method was examined by fixing the iron-containing enzyme catalase on cotton fabrics using different immobilization techniques. Sample preparation was carried out by dissolving the loaded fabrics in sulfuric acid before oxidising the residues with hydrogen peroxide. The iron concentrations were determined by flame atomic absorption spectrometry after calibration of the spectrometer with solutions of the free enzyme at different concentrations.

  19. Ultimate statistical physics: fluorescence of a single atom

    NASA Astrophysics Data System (ADS)

    Pomeau, Yves; Le Berre, Martine; Ginibre, Jean

    2016-10-01

    We discuss the statistics of emission of photons by a single atom or ion illuminated by a laser beam at the frequency of quasi-resonance between two energy levels, a situation that corresponds to real experiments. We extend this to the case of two laser beams resonant with the energy differences between two excited levels and the ground state (three level atom in V-configuration). We use a novel approach to this type of problem by considering a Kolmogorov equation for the probability distribution of the atomic state, which takes into account first the deterministic evolution of this state under the effect of the incoming laser beam and second the random emission of photons during the spontaneous decay of the excited state(s) to the ground state. This approach yields solvable equations in the two level atom case. For the three level atom case we set the problem and clearly define its frame. The results obtained are valid in both opposite limits of rare and frequent spontaneous decay, compared to the period of the optical Rabi oscillations due to the interaction between resonant excitation and atomic levels. Our analysis gives access to various statistical properties of the fluorescence light, including one showing that its fluctuations in time are not invariants under time reversal. This result makes evident the fundamentally irreversible character of quantum measurements, represented here by the emission of photons of fluorescence.

  20. Optimization of electrothermal atomization parameters for simultaneous multielement atomic absorption spectrometry

    USGS Publications Warehouse

    Harnly, J.M.; Kane, J.S.

    1984-01-01

    The effect of the acid matrix, the measurement mode (height or area), the atomizer surface (unpyrolyzed and pyrolyzed graphite), the atomization mode (from the wall or from a platform), and the atomization temperature on the simultaneous electrothermal atomization of Co, Cr, Cu, Fe, Mn, Mo, Ni, V, and Zn was examined. The 5% HNO3 matrix gave rise to severe irreproducibility using a pyrolyzed tube unless the tube was properly "prepared". The 5% HCl matrix did not exhibit this problem, and no problems were observed with either matrix using an unpyrolized tube or a pyrolyzed platform. The 5% HCl matrix gave better sensitivities with a pyrolyzed tube but the two matrices were comparable for atomization from a platform. If Mo and V are to be analyzed with the other seven elements, a high atomization temperature (2700??C or greater) is necessary regardless of the matrix, the measurement mode, the atomization mode, or the atomizer surface. Simultaneous detection limits (peak height with pyrolyzed tube atomization) were comparable to those of conventional atomic absorption spectrometry using electrothermal atomization above 280 nm. Accuracies and precisions of ??10-15% were found in the 10 to 120 ng mL-1 range for the analysis of NBS acidified water standards.

  1. Off-resonant squeezed vacuum effects on a driven two-level atom: absorption and intensity harmonics

    NASA Astrophysics Data System (ADS)

    Hassan, S. S.; Frege, O. M.; Nayak, N.

    1995-07-01

    The resonance fluorescence system of a coherently driven two-level atom in the presence of a broadband squeezed vacuum field whose central frequency is not in resonance with either the driving field frequency or the atomic transition frequency is analyzed. Solutions of the Bloch equations of the system are presented in terms of continued fractions for arbitrary strength of the coherent driving field. Numerical results are presented for the first-harmonic quadrature components of the absorption spectrum and the fluorescent intensity. The effects of the squeezed vacuum field detuning on the absorption spectrum result in hole burning or a dip structure in the weak-field case and two absorption-amplification peaks in the strong-field case. Results are sensitive to the relative phase of the squeezed vacuum.

  2. 21 CFR 862.2850 - Atomic absorption spectrophotometer for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Atomic absorption spectrophotometer for clinical... Laboratory Instruments § 862.2850 Atomic absorption spectrophotometer for clinical use. (a) Identification. An atomic absorption spectrophotometer for clinical use is a device intended to identify and...

  3. 21 CFR 862.2850 - Atomic absorption spectrophotometer for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Atomic absorption spectrophotometer for clinical... Laboratory Instruments § 862.2850 Atomic absorption spectrophotometer for clinical use. (a) Identification. An atomic absorption spectrophotometer for clinical use is a device intended to identify and...

  4. 21 CFR 862.2850 - Atomic absorption spectrophotometer for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Atomic absorption spectrophotometer for clinical... Laboratory Instruments § 862.2850 Atomic absorption spectrophotometer for clinical use. (a) Identification. An atomic absorption spectrophotometer for clinical use is a device intended to identify and...

  5. [Measurement of trace elements in blood serum by atomic absorption spectroscopy with electrothermal atomization].

    PubMed

    Rogul'skiĭ, Iu V; Danil'chenko, S N; Lushpa, A P; Sukhodub, L F

    1997-09-01

    Describes a method for measuring trace elements Cr, Mn, Co, Fe, Cu, Zn, and Mo in the blood serum using non-flame atomization (KAC 120.1 complex). Optimal conditions for preparing the samples were defined, temperature regimens for analysis of each element selected, and original software permitting automated assays created. The method permits analysis making use of the minimal samples: 0.1 ml per 10 parallel measurements, which is 100 times less than needed for atomic absorption spectroscopy with flame atomization of liquid samples. Metrological characteristics of the method are assessed.

  6. Absorption and Fluorescence Lineshape Theory for Polynomial Potentials.

    PubMed

    Anda, André; De Vico, Luca; Hansen, Thorsten; Abramavičius, Darius

    2016-12-13

    The modeling of vibrations in optical spectra relies heavily on the simplifications brought about by using harmonic oscillators. However, realistic molecular systems can deviate substantially from this description. We develop two methods which show that the extension to arbitrarily shaped potential energy surfaces is not only straightforward, but also efficient. These methods are applied to an electronic two-level system with potential energy surfaces of polynomial form and used to study anharmonic features such as the zero-phonon line shape and mirror-symmetry breaking between absorption and fluorescence spectra. The first method, which constructs vibrational wave functions as linear combinations of the harmonic oscillator wave functions, is shown to be extremely robust and can handle large anharmonicities. The second method uses the cumulant expansion, which is readily solved, even at high orders, thanks to an ideally suited matrix theorem.

  7. Cinchocaine hydrochloride determination by atomic absorption spectrometry and spectrophotometry.

    PubMed

    Abdel-Ghani, Nour T; Youssef, Ahmed F A; Awady, Mohamed A

    2005-05-01

    Two sensitive spectrophotometric and atomic absorption spectrometric procedures have been developed for determination of cinchocaine hydrochloride (Cin.Cl) in pure form and in pharmaceutical formulation. The spectrophotometric method was based on formation of an insoluble colored ion-associate between the cited drug and tetrathiocyanatocobaltate (CoTC) or hexathiocyanatochromate (CrTC) which dissolved and extracted in an organic solvent. The optimal experimental conditions for quantitative extraction such as pH, concentration of the reagents and solvent were studied. Toluene and iso-butyl alcohol proved to be the most suitable solvents for quantitative extraction of Cin-CoTC and Cin-CrTC ion-associates with maximum absorbance at 620 and 555 nm, respectively. The optimum concentration ranges, molar absorptivities, Ringbom ranges and Sandell sensitivities were also evaluated. The atomic absorption spectrometric method is based on measuring of the excess cobalt or chromium in the aqueous solution, after precipitation of the drug, at 240.7 and 357.9 nm, respectively. Linear application ranges, characteristic masses and detection limits were 57.99-361.9, 50.40 and 4.22 microg ml(-1) of Cin.Cl, in case of CoTC, while 37.99-379.9, 18.94 and 0.81 microg ml(-1) in case of CrTC.

  8. A Comprehensive X-Ray Absorption Model for Atomic Oxygen

    NASA Technical Reports Server (NTRS)

    Gorczyca, T. W.; Bautista, M. A.; Hasoglu, M. F.; Garcia, J.; Gatuzz, E.; Kaastra, J. S.; Kallman, T. R.; Manson, S. T.; Mendoza, C.; Raassen, A. J. J.; de Vries, C. P.; Zatsarinny, O.

    2013-01-01

    An analytical formula is developed to accurately represent the photoabsorption cross section of atomic Oxygen for all energies of interest in X-ray spectral modeling. In the vicinity of the K edge, a Rydberg series expression is used to fit R-matrix results, including important orbital relaxation effects, that accurately predict the absorption oscillator strengths below threshold and merge consistently and continuously to the above-threshold cross section. Further, minor adjustments are made to the threshold energies in order to reliably align the atomic Rydberg resonances after consideration of both experimental and observed line positions. At energies far below or above the K-edge region, the formulation is based on both outer- and inner-shell direct photoionization, including significant shake-up and shake-off processes that result in photoionization-excitation and double-photoionization contributions to the total cross section. The ultimate purpose for developing a definitive model for oxygen absorption is to resolve standing discrepancies between the astronomically observed and laboratory-measured line positions, and between the inferred atomic and molecular oxygen abundances in the interstellar medium from XSTAR and SPEX spectral models.

  9. Communication: Angular momentum alignment and fluorescence polarization of alkali atoms photodetached from helium nanodroplets

    NASA Astrophysics Data System (ADS)

    Hernando, Alberto; Beswick, J. Alberto; Halberstadt, Nadine

    2013-12-01

    The theory of photofragments angular momentum polarization is applied to the photodetachment of an electronically excited alkali atom from a helium nanocluster (N = 200). The alignment of the electronic angular momentum of the bare excited alkali atoms produced is calculated quantum mechanically by solving the excited states coupled equations with potentials determined by density functional theory (DFT). Pronounced oscillations as a function of excitation energy are predicted for the case of Na@(He)200, in marked contrast with the absorption cross-section and angular distribution of the ejected atoms which are smooth functions of the energy. These oscillations are due to quantum interference between different coherently excited photodetachment pathways. Experimentally, these oscillations should be reflected in the fluorescence polarization and polarization-resolved photoelectron yield of the ejected atoms, which are proportional to the electronic angular momentum alignment. In addition, this result is much more general than the test case of NaHe200 studied here. It should be observable for larger droplets, for higher excited electronic states, and for other alkali as well as for alkali-earth atoms. Detection of these oscillations would show that the widely used pseudo-diatomic model can be valid beyond the prediction of absorption spectra and could help in interpreting parts of the dynamics, as already hinted by some experimental results on angular anisotropy of bare alkali fragments.

  10. Communication: Angular momentum alignment and fluorescence polarization of alkali atoms photodetached from helium nanodroplets

    SciTech Connect

    Hernando, Alberto; Beswick, J. Alberto; Halberstadt, Nadine

    2013-12-14

    The theory of photofragments angular momentum polarization is applied to the photodetachment of an electronically excited alkali atom from a helium nanocluster (N = 200). The alignment of the electronic angular momentum of the bare excited alkali atoms produced is calculated quantum mechanically by solving the excited states coupled equations with potentials determined by density functional theory (DFT). Pronounced oscillations as a function of excitation energy are predicted for the case of Na@(He){sub 200}, in marked contrast with the absorption cross-section and angular distribution of the ejected atoms which are smooth functions of the energy. These oscillations are due to quantum interference between different coherently excited photodetachment pathways. Experimentally, these oscillations should be reflected in the fluorescence polarization and polarization-resolved photoelectron yield of the ejected atoms, which are proportional to the electronic angular momentum alignment. In addition, this result is much more general than the test case of NaHe{sub 200} studied here. It should be observable for larger droplets, for higher excited electronic states, and for other alkali as well as for alkali-earth atoms. Detection of these oscillations would show that the widely used pseudo-diatomic model can be valid beyond the prediction of absorption spectra and could help in interpreting parts of the dynamics, as already hinted by some experimental results on angular anisotropy of bare alkali fragments.

  11. The determination of vanadium in brines by atomic absorption spectroscopy

    USGS Publications Warehouse

    Crump-Wiesner, Hans J.; Feltz, H.R.; Purdy, W.C.

    1971-01-01

    A standard addition method is described for the determination of vanadium in brines by atomic absorption spectroscopy with a nitrous oxide-acetylene flame. Sample pH is adjusted to 1.0 with concentrated hydrochloric acid and the vanadium is directly extracted with 5% cupferron in methyl isobutyl ketone (MIBK). The ketone layer is then aspirated into the flame and the recorded absorption values are plotted as a function of the concentration of the added metal. As little as 2.5 ??g l-1 of vanadium can be detected under the conditions of the procedure. Tungsten and tin interfere when present in excess of 5 and 10 ??g ml-1, respectively. The concentrations of the two interfering ions normally found in brines are well below interference levels. ?? 1971.

  12. Absorption spectroscopy characterization measurements of a laser-produced Na atomic beam

    SciTech Connect

    Ching, C.H.; Bailey, J.E.; Lake, P.W.; Filuk, A.B.; Adams, R.G.; McKenney, J.

    1997-01-01

    A pulsed Na atomic beam source developed for spectroscopic diagnosis of a high-power ion diode is described. The goal is to produce a {approximately}10{sup 12}-cm{sup {minus}3}-density Na atomic beam that can be injected into the diode acceleration gap to measure electric and magnetic fields from the Stark and Zeeman effects through laser-induced fluorescence or absorption spectroscopy. A {approximately}10 ns full width at half-maximum (FWHM), 1.06 {mu}m, 0.6 J/cm{sup 2} laser incident through a glass slide heats a Na-bearing thin film, creating a plasma that generates a sodium vapor plume. A {approximately}1 {mu}s FWHM dye laser beam tuned to 5890 {Angstrom} is used for absorption measurement of the NaI resonant doublet by viewing parallel to the film surface. The dye laser light is coupled through a fiber to a spectrograph with a time-integrated charge-coupled-device camera. A two-dimensional mapping of the Na vapor density is obtained through absorption measurements at different spatial locations. Time-of-flight and Doppler broadening of the absorption with {approximately}0.1 {Angstrom} spectral resolution indicate that the Na neutral vapor temperature is about 0.5{endash}2 eV. Laser-induced fluorescence from {approximately}1{times}10{sup 12} cm{sup {minus}3} NaI 3s-3p lines observed with a streaked spectrograph provides a signal level sufficient for {approximately}{plus_minus}0.06 {Angstrom} wavelength shift measurements in a mock-up of an ion diode experiment. {copyright} {ital 1997 American Institute of Physics.}

  13. Absorption spectroscopy characterization measurements of a laser-produced Na atomic beam

    SciTech Connect

    Ching, C.H.; Bailey, J.E.; Lake, P.W.; Filuk, A.B.; Adams, R.G.; McKenney, J.

    1996-06-01

    This work describes a pulsed Na atomic beam source developed for spectroscopic diagnosis of a high-power ion diode on the Particle Beam Fusion Accelerator II. The goal is to produce a {approximately} 10{sup 12}-cm{sup {minus}3}-density Na atomic beam that can be injected into the diode acceleration gap to measure electric and magnetic fields from the Stark and Zeeman effects through laser-induced-fluorescence or absorption spectroscopy. A {approximately} 10 ns fwhm, 1.06 {micro}m, 0.6 J/cm{sup 2} laser incident through a glass slide heats a Na-bearing thin film, creating a plasma that generates a sodium vapor plume. A {approximately} 1 {micro}sec fwhm dye laser beam tuned to 5,890 {angstrom} is used for absorption measurement of the Na I resonant doublet by viewing parallel to the film surface. The dye laser light is coupled through a fiber to a spectrograph with a time-integrated CCD camera. A two-dimensional mapping of the Na vapor density is obtained through absorption measurements at different spatial locations. Time-of-flight and Doppler broadening of the absorption with {approximately} 0.1 {angstrom} spectral resolution indicate that the Na neutral vapor temperature is about 0.5 to 2 eV. Laser-induced-fluorescence from {approximately} 1 {times} 10{sup 12}-cm{sup {minus}3} Na I 3s-3p lines observed with a streaked spectrograph provides a signal level sufficient for {approximately} 0.06 {angstrom} wavelength shift measurements in a mock-up of an ion diode experiment.

  14. Oscillator strength measurements of atomic absorption lines from stellar spectra

    NASA Astrophysics Data System (ADS)

    Lobel, Alex

    2011-05-01

    Herein we develop a new method to determine oscillator strength values of atomic absorption lines with state-of-the-art detailed spectral synthesis calculations of the optical spectrum of the Sun and of standard spectral reference stars. We update the log(gf) values of 911 neutral lines observed in the KPNO-FTS flux spectrum of the Sun and high-resolution echelle spectra (R = 80 000) of Procyon (F5 IV-V) and Eps Eri (K2 V) observed with large signal-to-noise (S/N) ratios of 2000 using the new Mercator-Hermes spectrograph at La Palma Observatory (Spain). We find for 483 Fe I, 85 Ni I, and 51 Si I absorption lines in the sample a systematic overestimation of the literature log(gf) values with central line depths below 15%. We employ a curve-of-growth analysis technique to test the accuracy of the new oscillator strength values and compare calculated equivalent line widths to the Moore, Minnaert, and Houtgast atlas of the Sun. The online SpectroWeb database at http://spectra.freeshell.org interactively displays the observed and synthetic spectra and provides the new log(gf) values together with important atomic line data. The graphical database is under development for stellar reference spectra of every spectral sub-class observed with large spectral resolution and S/N ratios.

  15. A comprehensive X-ray absorption model for atomic oxygen

    SciTech Connect

    Gorczyca, T. W.; Bautista, M. A.; Mendoza, C.; Hasoglu, M. F.; García, J.; Gatuzz, E.; Kaastra, J. S.; Raassen, A. J. J.; De Vries, C. P.; Kallman, T. R.; Manson, S. T.; Zatsarinny, O.

    2013-12-10

    An analytical formula is developed to accurately represent the photoabsorption cross section of O I for all energies of interest in X-ray spectral modeling. In the vicinity of the K edge, a Rydberg series expression is used to fit R-matrix results, including important orbital relaxation effects, that accurately predict the absorption oscillator strengths below threshold and merge consistently and continuously to the above-threshold cross section. Further, minor adjustments are made to the threshold energies in order to reliably align the atomic Rydberg resonances after consideration of both experimental and observed line positions. At energies far below or above the K-edge region, the formulation is based on both outer- and inner-shell direct photoionization, including significant shake-up and shake-off processes that result in photoionization-excitation and double-photoionization contributions to the total cross section. The ultimate purpose for developing a definitive model for oxygen absorption is to resolve standing discrepancies between the astronomically observed and laboratory-measured line positions, and between the inferred atomic and molecular oxygen abundances in the interstellar medium from XSTAR and SPEX spectral models.

  16. Atomic Absorption Spectroscopy, Atomic Emission Spectroscopy, and Inductively Coupled Plasma-Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Miller, Dennis D.; Rutzke, Michael A.

    Atomic spectroscopy has played a major role in the development of our current database for mineral nutrients and toxicants in foods. When atomic absorption spectrometers became widely available in the 1960s, the development of atomic absorption spectroscopy (AAS) methods for accurately measuring trace amounts of mineral elements in biological samples paved the way for unprecedented advances in fields as diverse as food analysis, nutrition, biochemistry, and toxicology (1). The application of plasmas as excitation sources for atomic emission spectroscopy (AES) led to the commercial availability of instruments for inductively coupled plasma - atomic emission spectroscopy (ICP-AES) beginning in the late 1970s. This instrument has further enhanced our ability to measure the mineral composition of foods and other materials rapidly, accurately, and precisely. More recently, plasmas have been joined with mass spectrometers (MS) to form inductively coupled plasma-mass spectrometer ICP-MS instruments that are capable of measuring mineral elements with extremely low detection limits. These three instrumental methods have largely replaced traditional wet chemistry methods for mineral analysis of foods, although traditional methods for calcium, chloride, iron, and phosphorus remain in use today (see Chap. 12).

  17. Electric-field-induced changes in absorption and fluorescence of the green fluorescent protein chromophore in a PMMA film.

    PubMed

    Nakabayashi, Takakazu; Hino, Kazuyuki; Ohta, Yuka; Ito, Sayuri; Nakano, Hirofumi; Ohta, Nobuhiro

    2011-07-07

    External electric field effects on absorption, fluorescence, and fluorescence decay of p-HBDI that is a model compound of the chromophore of GFP have been examined in a poly(methyl methacrylate) film. The electroabsorption spectrum is similar in shape to the first derivative of the absorption spectrum, which results from the difference in molecular polarizability between the ground state and the Franck-Condon excited state. The electrophotoluminescence spectrum is dominated by the corresponding fluorescence spectrum, indicating the enhancement of the fluorescence intensity in the presence of external electric fields. The direct measurements of the electric field effect on the fluorescence decay profile suggest that the field-induced deceleration of the nonradiative process contributes to the increase in the fluorescence intensity in the presence of electric fields.

  18. X-ray fluorescence and absorption analysis of krypton in irradiated nuclear fuel

    NASA Astrophysics Data System (ADS)

    Degueldre, Claude; Mieszczynski, Cyprian; Borca, Camelia; Grolimund, Daniel; Martin, Matthias; Bertsch, Johannes

    2014-10-01

    The analysis of krypton in irradiated uranium dioxide fuel has been successfully achieved by X-ray fluorescence and X-ray absorption. The present study focuses on the analytical challenge of sample and sub-sample production to perform the analysis with the restricted conditions dictated by the radioprotection regulations. It deals also with all potential interferences that could affect the quality of the measurement in fluorescence as well as in absorption mode. The impacts of all dissolved gases in the fuel matrix are accounted for the analytical result quantification. The krypton atomic environment is ruled by the presence of xenon. Other gases such as residual argon and traces of helium or hydrogen are negligible. The results are given in term of density for krypton (∼3 nm-3) and xenon (∼20 nm-3). The presence of dissolved, interstitial and nano-phases are discussed together with other analytical techniques that could be applied to gain information on fission gas behaviour in nuclear fuels.

  19. Transient absorption spectra of the laser-dressed hydrogen atom

    NASA Astrophysics Data System (ADS)

    Murakami, Mitsuko; Chu, Shih-I.

    2013-10-01

    We present a theoretical study of transient absorption spectra of laser-dressed hydrogen atoms, based on numerical solutions of the time-dependent Schrödinger equation. The timing of absorption is controlled by the delay between an extreme ultra violet (XUV) pulse and an infrared (IR) laser field. The XUV pulse is isolated and several hundred attoseconds in duration, which acts as a pump to drive the ground-state electron to excited p states. The subsequent interaction with the IR field produces dressed states, which manifest as sidebands between the 1s-np absorption spectra separated by one IR-photon energy. We demonstrate that the population of dressed states is maximized when the timing of the XUV pulse coincides with the zero crossing of the IR field, and that their energies can be manipulated in a subcycle time scale by adding a chirp to the IR field. An alternative perspective to the problem is to think of the XUV pulse as a probe to detect the dynamical ac Stark shifts. Our results indicate that the accidental degeneracy of the hydrogen excited states is removed while they are dressed by the IR field, leading to large ac Stark shifts. Furthermore, we observe the Autler-Townes doublets for the n=2 and 3 levels using the 656 nm dressing field, but their separation does not agree with the prediction by the conventional three-level model that neglects the dynamical ac Stark shifts.

  20. Antimony quantification in Leishmania by electrothermal atomic absorption spectroscopy.

    PubMed

    Roberts, W L; Rainey, P M

    1993-05-15

    Tri- and pentavalent antimony were quantified in Leishmania mexicana pifanoi amastigotes and promastigotes by atomic absorption spectroscopy with electrothermal atomization. Leishmania grown in axenic culture were treated with either potassium antimony tartrate [Sb(III)] or sodium stibogluconate [Sb(V)]. The parasites were collected, digested with nitric acid, and subjected to atomic absorption spectroscopy. The method was linear from 0 to 7 ng of antimony. The interassay coefficients of variation were 9.6 and 5.7% (N = 5) for 0.52 and 3.7-ng samples of leishmanial antimony, respectively. The limit of detection was 95 pg of antimony. The assay was used to characterize Sb(III) and Sb(V) influx and efflux kinetics. Influx rates were determined at antimony concentrations that produced a 50% inhibition of growth (IC50). The influx rates of Sb(V) into amastigotes and promastigotes were 4.8 and 12 pg/million cells/h, respectively, at 200 micrograms antimony/ml. The influx rate of Sb(III) into amastigotes was 41 pg/million cells/h at 20 micrograms antimony/ml. Influx of Sb(III) into promastigotes at 1 microgram antimony/ml was rapid and reached a plateau of 175 pg/million cells in 2 h. Efflux of Sb(III) and Sb(V) from amastigotes and promastigotes exhibited biphasic kinetics. The initial (alpha) half-life of Sb(V) efflux was less than 4 min and that of Sb(III) was 1-2 h. The apparent terminal (beta) half-lives ranged from 7 to 14 h.

  1. Microwave-assisted synthesis of water-soluble, fluorescent gold nanoclusters capped with small organic molecules and a revealing fluorescence and X-ray absorption study

    NASA Astrophysics Data System (ADS)

    Helmbrecht, C.; Lützenkirchen-Hecht, D.; Frank, W.

    2015-03-01

    Colourless solutions of blue light-emitting, water-soluble gold nanoclusters (AuNC) were synthesized from gold colloids under microwave irradiation using small organic molecules as ligands. Stabilized by 1,3,5-triaza-7-phosphaadamantane (TPA) or l-glutamine (GLU), fluorescence quantum yields up to 5% were obtained. AuNC are considered to be very promising for biological labelling, optoelectronic devices and light-emitting materials but the structure-property relationships have still not been fully clarified. To expand the knowledge about the AuNC apart from their fluorescent properties they were studied by X-ray absorption spectroscopy elucidating the oxidation state of the nanoclusters' gold atoms. Based on curve fitting of the XANES spectra in comparison to several gold references, optically transparent fluorescent AuNC are predicted to be ligand-stabilized Au5+ species. Additionally, their near edge structure compared with analogous results of polynuclear clusters known from the literature discloses an increasing intensity of the feature close to the absorption edge with decreasing cluster size. As a result, a linear relationship between the cluster size and the X-ray absorption coefficient can be established for the first time.Colourless solutions of blue light-emitting, water-soluble gold nanoclusters (AuNC) were synthesized from gold colloids under microwave irradiation using small organic molecules as ligands. Stabilized by 1,3,5-triaza-7-phosphaadamantane (TPA) or l-glutamine (GLU), fluorescence quantum yields up to 5% were obtained. AuNC are considered to be very promising for biological labelling, optoelectronic devices and light-emitting materials but the structure-property relationships have still not been fully clarified. To expand the knowledge about the AuNC apart from their fluorescent properties they were studied by X-ray absorption spectroscopy elucidating the oxidation state of the nanoclusters' gold atoms. Based on curve fitting of the XANES

  2. Fluorescence (TALIF) measurement of atomic hydrogen concentration in a coplanar surface dielectric barrier discharge

    NASA Astrophysics Data System (ADS)

    Mrkvičková, M.; Ráheľ, J.; Dvořák, P.; Trunec, D.; Morávek, T.

    2016-10-01

    Spatially and temporally resolved measurements of atomic hydrogen concentration above the dielectric of coplanar barrier discharge are presented for atmospheric pressure in 2.2% H2/Ar. The measurements were carried out in the afterglow phase by means of two-photon absorption laser-induced fluorescence (TALIF). The difficulties of employing the TALIF technique in close proximity to the dielectric surface wall were successfully addressed by taking measurements on a suitable convexly curved dielectric barrier, and by proper mathematical treatment of parasitic signals from laser-surface interactions. It was found that the maximum atomic hydrogen concentration is situated closest to the dielectric wall from which it gradually decays. The maximum absolute concentration was more than 1022 m-3. In the afterglow phase, the concentration of atomic hydrogen above the dielectric surface stays constant for a considerable time (10 μs-1 ms), with longer times for areas situated farther from the dielectric surface. The existence of such a temporal plateau was explained by the presented 1D model: the recombination losses of atomic hydrogen farther from the dielectric surface are compensated by the diffusion of atomic hydrogen from regions close to the dielectric surface. The fact that a temporal plateau exists even closest to the dielectric surface suggests that the dielectric surface acts as a source of atomic hydrogen in the afterglow phase.

  3. The role of atomic absorption spectrometry in geochemical exploration

    USGS Publications Warehouse

    Viets, J.G.; O'Leary, R. M.

    1992-01-01

    In this paper we briefly describe the principles of atomic absorption spectrometry (AAS) and the basic hardware components necessary to make measurements of analyte concentrations. Then we discuss a variety of methods that have been developed for the introduction of analyte atoms into the light path of the spectrophotometer. This section deals with sample digestion, elimination of interferences, and optimum production of ground-state atoms, all critical considerations when choosing an AAS method. Other critical considerations are cost, speed, simplicity, precision, and applicability of the method to the wide range of materials sampled in geochemical exploration. We cannot attempt to review all of the AAS methods developed for geological materials but instead will restrict our discussion to some of those appropriate for geochemical exploration. Our background and familiarity are reflected in the methods we discuss, and we have no doubt overlooked many good methods. Our discussion should therefore be considered a starting point in finding the right method for the problem, rather than the end of the search. Finally, we discuss the future of AAS relative to other instrumental techniques and the promising new directions for AAS in geochemical exploration. ?? 1992.

  4. Containerless high temperature property measurements by atomic fluorescence

    NASA Technical Reports Server (NTRS)

    Schiffman, R. A.; Walker, C. A.

    1984-01-01

    Laser induced fluorescence (LIF) techniques for containerless study of high temperature processes and material properties was studied. Gas jet and electromagnetic levitation and electromagnetic and laser heating techniques are used with LIF in earth-based containerless high temperature experiments. Included are the development of an apparatus and its use in the studies of (1) chemical reactions on Al2O3, molybdenum, tungsten and LaB6 specimens, (2) methods for noncontact specimen temperature measurement, (3) levitation jet properties and (4) radiative lifetime and collisional energy transfer rates for electronically excited atoms.

  5. Simultaneous Atomic Absorption Spectrometry for Cadmium and Lead Determination in Wastewater: A Laboratory Exercise

    ERIC Educational Resources Information Center

    Correia, Paulo R. M.; Oliveira, Pedro V.

    2004-01-01

    The simultaneous determination of cadmium and lead by multi-element atomic absorption spectrometry with electrochemical atomization is proposed by employing a problem-based approach. The reports indicate that the students assimilated the principles of the simultaneous atomic absorption spectrometry (SIMAAS), the role of the chemical modifier, the…

  6. High resolution laser induced fluorescence Doppler velocimetry utilizing saturated absorption spectroscopy

    SciTech Connect

    Aramaki, Mitsutoshi; Ogiwara, Kohei; Etoh, Shuzo; Yoshimura, Shinji; Tanaka, Masayoshi Y.

    2009-05-15

    A high resolution laser induced fluorescence (LIF) system has been developed to measure the flow velocity field of neutral particles in an electron-cyclotron-resonance argon plasma. The flow velocity has been determined by the Doppler shift of the LIF spectrum, which is proportional to the velocity distribution function. Very high accuracy in velocity determination has been achieved by installing a saturated absorption spectroscopy unit into the LIF system, where the absolute value and scale of laser wavelength are determined by using the Lamb dip and the fringes of a Fabry-Perot interferometer. The minimum detectable flow velocity of a newly developed LIF system is {+-}2 m/s, and this performance remains unchanged in a long-time experiment. From the radial measurements of LIF spectra of argon metastable atoms, it is found that there exists an inward flow of neutral particles associated with neutral depletion.

  7. Graphite furnace atomic absorption elemental analysis of ecstasy tablets.

    PubMed

    French, Holly E; Went, Michael J; Gibson, Stuart J

    2013-09-10

    Six metals (copper, magnesium, barium, nickel, chromium and lead) were determined in two separate batches of seized ecstasy tablets by graphite furnace atomic absorption spectroscopy (GFAAS) following digestion with nitric acid and hydrogen peroxide. Large intra-batch variations were found as expected for tablets produced in clandestine laboratories. For example, nickel in batch 1 was present in the range 0.47-13.1 parts per million (ppm) and in batch 2 in the range 0.35-9.06 ppm. Although batch 1 had significantly higher 3,4-methylenedioxy-N-methamphetamine (MDMA) content than batch 2, barium was the only element which discriminated between the two ecstasy seizures (batch 1: 0.19-0.66 ppm, batch 2: 3.77-5.47 ppm).

  8. Substituent Effects on the Absorption and Fluorescence Properties of Anthracene.

    PubMed

    Abou-Hatab, Salsabil; Spata, Vincent A; Matsika, Spiridoula

    2017-02-16

    Substitution can be used to efficiently tune the photophysical properties of chromophores. In this study, we examine the effect of substituents on the absorption and fluorescence properties of anthracene. The effects of mono-, di-, and tetrasubstitution of electron-donating and -withdrawing functional groups were explored. In addition, the influence of a donor-acceptor substituent pair and the position of substitution were investigated. Eleven functional groups were varied on positions 1, 2, and 9 of anthracene, and on position 6 of 2-methoxyanthracene and 2-carboxyanthracene. Moreover, the donor-acceptor pair NH2/CO2H was added on different positions of anthracene for additional studies of doubly substituted anthracenes. Finally, we looked into quadruple substitutions on positions 1,4,5,8 and 2,3,6,7. Vertical excitation energies and oscillator strengths were computed using density functional theory with the hybrid CAM-B3LYP functional and 6-311G(d) basis set. Correlations between the excitation energies or oscillator strengths of the low-lying bright La state and the Hammett sigma parameter, σp(+), of the substituents were examined. The energy is red-shifted for all cases of substitution. Oscillator strengths increase when substituents are placed along the direction of the transition dipole moment of the bright La excited state. Substitution of long chain conjugated groups significantly increases the oscillator strength in comparison to the cases for other substituents. In addition, the results of quadruply substituted geometries reveal symmetric substitution at the 1,4,5,8 positions significantly increases the oscillator strength and can lower the band gap compared to that of the unsubstituted anthracene molecule by up to 0.5 eV.

  9. Atomic absorption background of Ba in EXAFS analysis of BaFe(12)O(19) nanoparticles.

    PubMed

    Padeznik Gomilšek, Jana; Kodre, Alojz; Arčon, Iztok; de Panfilis, Simone; Makovec, Darko

    2011-07-01

    The approximate barium X-ray atomic absorption in the energy region of L-edges is reconstructed from the absorption spectrum of an aqueous solution of BaCl(2). The result is corroborated by comparison with pure atomic absorption spectra of neighbour elements Xe and Cs. The application of the atomic absorption signal as a proper EXAFS background is demonstrated and discussed in the analysis of Ba hexaferrite nanoparticles with a very weak structural signal. The essential gain is found in the decrease of uncertainty intervals of structural parameters and their correlations. A simple analytical model of the absorption background for the practical EXAFS analysis is demonstrated.

  10. Absorption and fluorescence properties of aryl substituted porphyrins in different media

    NASA Astrophysics Data System (ADS)

    Bozkurt, Serap Seyhan; Merdivan, Melek; Ayata, Sevda

    2010-02-01

    Absorption and fluorescence properties of aryl substituted porphyrins, 5,10,15,20-tetra-4-oxy(aceticacid)phenylporphyrin (TAPP), 5,10,15,20-tetra-(4-phenoxyphenyl) porphyrin (TPPP), 5,10,15,20-tetra-(3-bromo-4-hydroxyphenyl) porphyrin (TBHPP), and 5,10,15,20-tetra-p-chloromethylphenyl porphyrin (CMPP) were investigated. The UV/vis absorption, fluorescence and excited spectra as the fluorescence quantum yields and fluorescence lifetimes for the compounds were measured in organic solvents (chloroform (CHCl 3), tetrahydrofuran (THF)) and immobilized media (PVC film, sol-gel matrix). The fluorescence quantum yields of TAPP and TPPP were higher than the others. The fluorescence lifetimes of all studied porphyrin derivates were found to be fifty percent lower and their fluorescence intensities were increased fifty percent more in both of immobilized mediums, as compared to organic solvents.

  11. Flame-in-gas-shield and miniature diffusion flame hydride atomizers for atomic fluorescence spectrometry: optimization and comparison

    NASA Astrophysics Data System (ADS)

    Marschner, Karel; Musil, Stanislav; Dědina, Jiří

    2015-07-01

    A detailed optimization of relevant experimental parameters of two hydride atomizers for atomic fluorescence spectrometry: flame-in-gas-shield atomizer with a two-channel shielding unit and a standard atomizer for atomic fluorescence spectrometry, miniature diffusion flame, was performed. Arsine, generated by the reaction with NaBH4 in a flow injection arrangement, was chosen as the model hydride. Analytical characteristics of both the atomizers (sensitivity, noise, limits of detection) were compared. Under optimum conditions sensitivity obtained with flame-in-gas-shield atomizer was approximately twice higher than with miniature diffusion flame. The additional advantage of flame-in-gas-shield atomizer is significantly lower flame emission resulting in a better signal to noise ratio. The resulting arsenic limits of detection for miniature diffusion flame and flame-in-gas-shield atomizer were 3.8 ng l- 1 and 1.0 ng l- 1, respectively.

  12. [Measurement of atomic number of alkali vapor and pressure of buffer gas based on atomic absorption].

    PubMed

    Zheng, Hui-jie; Quan, Wei; Liu, Xiang; Chen, Yao; Lu, Ji-xi

    2015-02-01

    High sensitivitymagnetic measurementscanbe achieved by utilizing atomic spinmanipulation in the spin-exchange-relaxation-free (SERF) regime, which uses an alkali cell as a sensing element. The atomic number density of the alkali vapor and the pressure of the buffer gasare among the most important parameters of the cell andrequire accurate measurement. A method has been proposed and developedto measure the atomic number density and the pressure based on absorption spectroscopy, by sweeping the absorption line and fittingthe experiment data with a Lorentzian profile to obtainboth parameters. Due to Doppler broadening and pressure broadening, which is mainly dominated by the temperature of the cell and the pressure of buffer gas respectively, this work demonstrates a simulation of the errorbetween the peaks of the Lorentzian profile and the Voigt profile caused by bothfactors. The results indicates that the Doppler broadening contribution is insignificant with an error less than 0.015% at 313-513 K for a 4He density of 2 amg, and an error of 0.1% in the presence of 0.6-5 amg at 393 K. We conclude that the Doppler broadening could be ignored under above conditions, and that the Lorentzianprofile is suitably applied to fit the absorption spectrumobtainingboth parameters simultaneously. In addition we discuss the resolution and the instability due to thelight source, wavelength and the temperature of the cell. We find that the cell temperature, whose uncertainty is two orders of magnitude larger than the instability of the light source and the wavelength, is one of the main factors which contributes to the error.

  13. Simultaneous acquisition of absorption and fluorescence spectra of strong absorbers utilizing an evanescent supercontinuum.

    PubMed

    Kiefer, Johannes

    2016-12-15

    The determination of the absorption and emission spectra of strongly absorbing molecules is challenging, and the data can be biased by self-absorption of the fluorescence signal. To overcome this problem, a total internal reflection approach is proposed. The strongly absorbing sample is placed in an evanescent field of the radiation of a supercontinuum source. The collimated reflected light encodes the absorption spectrum, and the isotropic fluorescence emission is collected in a direction perpendicular to the surface at the same time. This ensures that the emitted light has a minimum possibility of self-absorption inside the sample.

  14. Etalon-induced baseline drift and correction in atom flux sensors based on atomic absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Du, Yingge; Chambers, Scott A.

    2014-10-01

    Atom flux sensors based on atomic absorption (AA) spectroscopy are of significant interest in thin film growth as they can provide unobtrusive, element specific real-time flux sensing and control. The ultimate sensitivity and performance of these sensors are strongly affected by baseline drift. Here we demonstrate that an etalon effect resulting from temperature changes in optical viewport housings is a major source of signal instability, which has not been previously considered, and cannot be corrected using existing methods. We show that small temperature variations in the fused silica viewports can introduce intensity modulations of up to 1.5% which in turn significantly deteriorate AA sensor performance. This undesirable effect can be at least partially eliminated by reducing the size of the beam and tilting the incident light beam off the viewport normal.

  15. Dye-doped sol-gel materials for two-photon absorption induced fluorescence

    NASA Astrophysics Data System (ADS)

    Canva, Michael; Roger, Gisèle; Cassagne, Florence; Lévy, Yves; Brun, Alain; Chaput, Frédéric; Boilot, Jean-Pierre; Rapaport, Alexandra; Heerdt, Céline; Bass, Michael

    2002-01-01

    Two-photon absorption (TPA) and subsequent fluorescence properties of laser dyes are retained when doped into solid state sol-gel materials. These properties were demonstrated to be applicable in true 3D displays.

  16. Determination of Aluminum Concentration in Seawater by Colorimetry and Atomic Absorption Spectroscopy.

    DTIC Science & Technology

    1972-11-30

    this was also high. 5 . ,Irj ~ - • lri*; llo. TALLE 2 ATOMIC ABSORPTION SPECTROSCOPY DETEPIJINATION OF ALUMINU1 CONCENTRATIO11 OF SEAWATER OCEAN...Concentration in Seawater by Colorimetr-y and Atomic Absorption Spectroscopy Charles A. Greene, Jr. and Everett N. Jones Ocean Science Department T14

  17. Determination of gold in geologic materials by solvent extraction and atomic-absorption spectrometry

    USGS Publications Warehouse

    Huffman, Claude; Mensik, J.D.; Riley, L.B.

    1967-01-01

    The two methods presented for the determination of traces of gold in geologic materials are the cyanide atomic-absorption method and the fire-assay atomic-absorption method. In the cyanide method gold is leached with a sodium-cyanide solution. The monovalent gold is then oxidized to the trivalent state and concentrated by extracting into methyl isobutyl ketone prior to estimation by atomic absorption. In the fire-assay atomic-absorption method, the gold-silver bead obtained from fire assay is dissolved in nitric and hydrochloric acids. Gold is then concentrated by extracting into methyl isobutyl ketone prior to determination by atomic absorption. By either method concentrations as low as 50 parts per billion of gold can be determined in a 15-gram sample.

  18. Ultrashort Two-Photon-Absorption Laser-Induced Fluorescence in Nanosecond-Duration, Repetitively Pulsed Discharges

    NASA Astrophysics Data System (ADS)

    Schmidt, Jacob Brian

    Absolute number densities of atomic species produced by nanosecond duration, repetitively pulsed electric discharges are measured by two-photon absorption laser-induced fluorescence (TALIF). Relatively high plasma discharge pulse energies (=1 mJ/pulse) are used to generate atomic hydrogen, oxygen, and nitrogen in a variety of discharge conditions and geometries. Unique to this work is the development of femtosecond-laser-based TALIF (fs-TALIF). Fs-TALIF offers a number of advantages compared to more conventional ns-pulse-duration laser systems, including better accuracy of direct quenching measurements in challenging environments, significantly reduced photolytic interference including photo-dissociation and photo-ionization, higher signal and increased laser-pulse bandwidth, the ability to collect two-dimensional images of atomic species number densities with far greater spatial resolution compared with more conventional diagnostics, and much higher laser repetition rates allowing for more efficient and accurate measurements of atomic species number densities. In order to fully characterize the fs-TALIF diagnostic and compare it with conventional ns-TALIF, low pressure (100 Torr) ns-duration pulsed discharges are operated in mixtures of H2, O2, and N2 with different buffer gases including argon, helium, and nitrogen. These discharge conditions are used to demonstrate the capability for two-dimensional imaging measurements. The images produced are the first of their kind and offer quantitative insight into spatially and temporally resolved kinetics and transport in ns-pulsed discharge plasmas. The two-dimensional images make possible comparison with high-fidelity plasma kinetics models of the presented data. The comparison with the quasi-one-dimensional kinetic model show good spatial and temporal agreement. The same diagnostics are used at atmospheric pressure, when atomic oxygen fs-TALIF is performed in an atmospheric-pressure plasma jet (APPJ). Here, the

  19. Feasibility of filter atomization in high-resolution continuum source atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Heitmann, Uwe; Becker-Ross, Helmut; Katskov, Dmitri

    2006-03-01

    A prototype spectrometer for high-resolution continuum source atomic absorption spectrometry (HR-CS AAS), built at ISAS Berlin, Germany, was combined with a graphite filter atomizer (GFA), earlier developed at TUT, Pretoria, South Africa. The furnace and auto-sampler units from a commercial AA spectrometer, model AAS vario 6 (Analytik Jena AG, Jena, Germany), were employed in the instrument. Instead of conventional platform tube, the GFA was used to provide low measurement susceptibility to interferences and short determination cycle. The GFA was modified according to the design of the furnace unit and optimal physical parameters of its components (filter and collector) found. Afterwards, optimal GFA was replicated and tested to outline analytical performances of the HR-CS GFA AA spectrometer in view of prospects of multi-element analysis. In particular, reproducibility of performances, repeatability of analytical signals, lifetime, temperature limit and duration of the measurement cycle were examined, and elements available for determination justified. The results show that the peak area of the atomic absorption signal is reproduced in various GFA copies within ± 4% deviation range. The GFA can stand temperatures of 2800 °C with 6 s hold time for 55 temperature cycles, and 2700 °C (8 s) for about 200 cycles. Only the external tube is prone to destruction while the filter and collector do not show any sign of erosion caused by temperature or aggressive matrix. Analytical signals are affected insignificantly by tube aging. Repeatability of the peak area remains within 1.1-1.7% RSD over more than hundred determination cycles. Peak areas are proportional to the sample volume of injected organic and inorganic liquids up to at least 50 μL. The drying stage is combined with hot sampling and cut down to 15-20 s. The list of metals available for determination with full vapor release includes Al, Co, Cr, Ni, Pt as well as more volatile metals. Characteristic masses at

  20. pH-Induced changes in electronic absorption and fluorescence spectra of phenazine derivatives

    NASA Astrophysics Data System (ADS)

    Ryazanova, O. A.; Voloshin, I. M.; Makitruk, V. L.; Zozulya, V. N.; Karachevtsev, V. A.

    2007-04-01

    The visible electronic absorption and fluorescence spectra as well as fluorescence polarization degrees of imidazo-[4,5-d]-phenazine (F1), 2-methylimidazo-[4,5-d]-phenazine (F2), 2-trifluoridemethylimidazo-[4,5-d]-phenazine (F3), 1,2,3-triazole-[4,5-d]-phenazine (F4) and their glycosides, imidazo-[4,5-d]-phenazine-N1-β- D-ribofuranoside (F1rib), 1,2,3-triazole-[4,5-d]-phenazine-N1-β- D-glucopyranoside (F4gl), were investigated in aqueous buffered solutions over the pH range of 0-12, where the spectral transformations were found to be reversible. The effects of protonation and deprotonation on spectral properties of these dyes were studied. We have determined the ranges of pH, where individual ionic species are predominant. In aqueous buffered solutions the fluorescence was found only for neutral species of F1, F1rib, F2, and F4gl dyes, whereas for the ionic forms of these dyes, as well as for F3 and F4 ones, the fluorescence has not been detected. The concentrational deprotonation p Ka values were evaluated from experimental data. It was shown that donor-acceptor properties of the substituent group in the second position of the pentagonal ring substantially affect the values of the deprotonation constants and the character of protonation for chromophore. The substitution of a hydrogen atom in the NH-group by the sugar residue blocks the formation of the anionic species, and results in enhancement of the dye emission intensity. The steep emission dependence for F1 and F1rib over pH range of 0-7 with intensities ratio of IpH 7/ IpH 1 = 60 allows us to propose them as possible indicator dyes in luminescence based pH sensors for investigation of processes accompanied by acidification, e.g. as gastric pH-sensors. A comparative analysis of the studied dyes has shown that F4gl is the most promising compound to be used as a fluorescent probe for investigation of molecular hybridization of nucleic acids.

  1. Uranium isotopes quantitatively determined by modified method of atomic absorption spectrophotometry

    NASA Technical Reports Server (NTRS)

    Lee, G. H.

    1967-01-01

    Hollow-cathode discharge tubes determine the quantities of uranium isotopes in a sample by using atomic absorption spectrophotometry. Dissociation of the uranium atoms allows a large number of ground state atoms to be produced, absorbing the incident radiation that is different for the two major isotopes.

  2. Electrothermal atomic absorption spectrophotometry of nickel in tissue homogenates

    SciTech Connect

    Sunderman, F.W. Jr.; Marzouk, A.; Crisostomo, M.C.; Weatherby, D.R.

    1985-01-01

    A method for analysis of Ni concentrations in tissues is described, which involves (a) tissue dissection with metal-free obsidian knives, (b) tissue homogenization in polyethylene bags by use by a Stomacher blender, (c) oxidative digestion with mixed nitric, sulfuric, and perchloric acids, and (d) quantitation of Ni by electrothermal atomic absorption spectrophotometry with Zeeman background correction. The detection limit for Ni in tissues is 10 ng per g, dry weight; the coefficient of variation ranges from 7 to 15%, depending on the tissue Ni concentration; the recovery of Ni added in concentration of 20 ng per g, dry weight, to kidney homogenates averages 101 +/- 8% (mean +/-SD). In control rats, Ni concentrations are highest in lung (102 +/- 39 ng per g, dry weight) and lowest in spleen (35 +/- 16 ng per g, dry wt.). In descending order of Ni concentrations, the tissues of control rats rank as follows: lung > heart > bone > kidney > brain > testis > fat > liver > spleen. In rats killed 24 h after sc injection of NiCl/sub 2/ (0.125 mmol per kg, body weight) Ni concentrations are highest in kidney (17.7 +/- 2.5 ..mu..g per g, dry weight) and lowest in brain (0.38 +/- 0.14 ..mu..g per g, dry weight). In descending order of Ni concentrations, the tissues of NiCl/sub 2/-treated rats rank as follows: kidney >> lung > spleen > testis > heart > fat > liver > bone > brain. The present method fills the need for an accurate, sensitive, and practical technique to determine tissue Ni concentrations, with stringent precautions to minimize Ni contamination during tissue sampling and processing. 35 references, 5 figures, 1 table.

  3. Determination of mercury in hair: Comparison between gold amalgamation-atomic absorption spectrometry and mass spectrometry.

    PubMed

    Domanico, Francesco; Forte, Giovanni; Majorani, Costanza; Senofonte, Oreste; Petrucci, Francesco; Pezzi, Vincenzo; Alimonti, Alessandro

    2016-09-29

    Mercury is a heavy metal that causes serious health problems in exposed subjects. The most toxic form, i.e., methylmercury (MeHg), is mostly excreted through human hair. Numerous analytical methods are available for total Hg analysis in human hair, including cold vapour atomic fluorescence spectrometry (CV-AFS), inductively coupled plasma mass spectrometry (ICP-MS) and thermal decomposition amalgamation atomic absorption spectrometry (TDA-AAS). The aim of the study was to compare the TDA-AAS with the ICP-MS in the Hg quantification in human hair. After the washing procedure to minimize the external contamination, from each hair sample two aliquots were taken; the first was used for direct analysis of Hg by TDA-AAS and the second was digested for Hg determination by the ICP-MS. Results indicated that the two data sets were fully comparable (median; TDA-AAS, 475ngg(-1); ICP-MS, 437ngg(-1)) and were not statistically different (Mann-Whitney test; p=0.44). The two techniques presented results with a good coefficient of correlation (r=0.94) despite different operative ranges and method limits. Both techniques satisfied internal performance requirements and the parameters for method validation resulting sensitive, precise and reliable. Finally, the use of the TDA-AAS can be considered instead of the ICP-MS in hair analysis in order to reduce sample manipulation with minor risk of contamination, less time consuming due to the absence of the digestion step and cheaper analyses.

  4. Atomic-absorption determination of beryllium in geological materials by use of electrothermal atomization

    USGS Publications Warehouse

    Campbell, E.Y.; Simon, F.O.

    1978-01-01

    A method is described for the atomic-absorption determination of beryllium in geological materials, that utilizes electrothermal atomization after a separation by solvent extraction. Samples are decomposed with hydrofluoric acid and nitric acid in Teflon-lined pressure decomposition vessels. Beryllium is isolated by its extraction as beryllium acetylacetonate at pH 8 into xylene and back-extraction in 3M hydrochloric acid. The method has been successfully applied to the determination of beryllium in 14 U.S. Geological Survey standard rocks. Four subsamples from four bottles of each standard sample were analysed in random order. The mean beryllium contents (ppm) are: AGV-1, 1.98; PCC-1, 0.024; MAG-1, 2.84; BHVO-1, 0.90; DTS-1, 0.026; SCo-1, 1.74; SDC-1, 2.52; BCR-1, 1.44; GSP-1, 1.22; SGR-1, 0.86; QLO-1, 1.83; RGM-1, 2.21; STM-1, 8.75; G-2, 2.29. An analysis of variance shows that all the samples may be considered homogeneous at F0.95 except AGV-1 and DTS-1 which may be considered homogeneous at F0.99. ?? 1978.

  5. Implantable CMOS imaging device with absorption filters for green fluorescence imaging

    NASA Astrophysics Data System (ADS)

    Sunaga, Yoshinori; Haruta, Makito; Takehara, Hironari; Ohta, Yasumi; Motoyama, Mayumi; Noda, Toshihiko; Sasagawa, Kiyotaka; Tokuda, Takashi; Ohta, Jun

    2014-03-01

    Green fluorescent materials such as Green Fluorescence Protein (GFP) and fluorescein are often used for observing neural activities. Thus, it is important to observe the fluorescence in a freely moving state in order to understand neural activities corresponding to behaviors. In this work, we developed an implantable CMOS imaging device for in-vivo green fluorescence imaging with efficient excitation light rejection using a combination of absorption filters. An interference filter is usually used for a fluorescence microscope in order to achieve high fluorescence imaging sensitivity. However, in the case of the implantable device, interference filters are not suitable because their transmission spectra depend on incident angle. To solve this problem we used two kinds of absorption filters that do not have angle dependence. An absorption filter consisting of yellow dye (VARYFAST YELLOW 3150) was coated on the pixel array of an image sensor. The rejection ratio of ideal excitation light (490 nm) against green fluorescence (510 nm) was 99.66%. However, the blue LED as an excitation light source has a broad emission spectrum and its intensity at 510 nm is 2.2 x 10-2 times the emission peak intensity. By coating LEDs with the emission absorption filters, the intensity of the unwanted component of the excitation light was reduced to 1.4 x 10-4. Using the combination of absorption filters, we achieved excitation light transmittance of 10-5 onto the image sensor. It is expected that high-sensitivity green fluorescence imaging of neural activities in a freely moving mouse will be possible by using this technology.

  6. Magnetic fluorescent lamp having reduced ultraviolet self-absorption

    DOEpatents

    Berman, Samuel M.; Richardson, Robert W.

    1985-01-01

    The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly (10) is enhanced by providing means (30) for establishing a magnetic field with lines of force along the path of electron flow through the bulb (12) of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

  7. Laser-induced fluorescence detection strategies for sodium atoms and compounds in high-pressure combustors

    NASA Technical Reports Server (NTRS)

    Weiland, Karen J. R.; Wise, Michael L.; Smith, Gregory P.

    1993-01-01

    A variety of laser-induced fluorescence schemes were examined experimentally in atmospheric pressure flames to determine their use for sodium atom and salt detection in high-pressure, optically thick environments. Collisional energy transfer plays a large role in fluorescence detection. Optimum sensitivity, at the parts in 10 exp 9 level for a single laser pulse, was obtained with the excitation of the 4p-3s transition at 330 nm and the detection of the 3d-3p fluorescence at 818 nm. Fluorescence loss processes, such as ionization and amplified spontaneous emission, were examined. A new laser-induced atomization/laser-induced fluorescence detection technique was demonstrated for NaOH and NaCl. A 248-nm excimer laser photodissociates the salt molecules present in the seeded flames prior to atom detection by laser-induced fluorescence.

  8. Americium characterization by X-ray fluorescence and absorption spectroscopy in plutonium uranium mixed oxide

    NASA Astrophysics Data System (ADS)

    Degueldre, Claude; Cozzo, Cedric; Martin, Matthias; Grolimund, Daniel; Mieszczynski, Cyprian

    2013-06-01

    Plutonium uranium mixed oxide (MOX) fuels are currently used in nuclear reactors. The actinides in these fuels need to be analyzed after irradiation for assessing their behaviour with regard to their environment and the coolant. In this work the study of the atomic structure and next-neighbour environment of Am in the (Pu,U)O2 lattice in an irradiated (60 MW d kg-1) MOX sample was performed employing micro-X-ray fluorescence (µ-XRF) and micro-X-ray absorption fine structure (µ-XAFS) spectroscopy. The chemical bonds, valences and stoichiometry of Am (˜0.66 wt%) are determined from the experimental data gained for the irradiated fuel material examined in its peripheral zone (rim) of the fuel. In the irradiated sample Am builds up as Am3+ species within an [AmO8]13- coordination environment (e.g. >90%) and no (<10%) Am(IV) or (V) can be detected in the rim zone. The occurrence of americium dioxide is avoided by the redox buffering activity of the uranium dioxide matrix.

  9. Two photon absorption laser induced fluorescence measurements of neutral density in a helicon plasma

    SciTech Connect

    Galante, M. E.; Magee, R. M.; Scime, E. E.

    2014-05-15

    We have developed a new diagnostic based on two-photon absorption laser induced fluorescence (TALIF). We use a high intensity (5 MW/cm{sup 2}), narrow bandwidth (0.1 cm{sup −1}) laser to probe the ground state of neutral hydrogen, deuterium and krypton with spatial resolution better than 0.2 cm, a time resolution of 10 ns, and a measurement cadence of 20 Hz. Here, we describe proof-of-principle measurements in a helicon plasma source that demonstrate the TALIF diagnostic is capable of measuring neutral densities spanning four orders of magnitude; comparable to the edge neutral gradients predicted in the DIII-D tokamak pedestal. The measurements are performed in hydrogen and deuterium plasmas and absolute calibration is accomplished through TALIF measurements in neutral krypton. The optical configuration employed is confocal, i.e., both light injection and collection are accomplished with a single lens through a single optical port in the vacuum vessel. The wavelength resolution of the diagnostic is sufficient to separate hydrogen and deuterium spectra and we present measurements from mixed hydrogen and deuterium plasmas that demonstrate isotopic abundance measurements are feasible. Time resolved measurements also allow us to explore the evolution of the neutral hydrogen density and temperature and effects of wall recycling. We find that the atomic neutral density grows rapidly at the initiation of the discharge, reaching the steady-state value within 1 ms. Additionally, we find that neutral hydrogen atoms are born with 0.08 eV temperatures, not 2 eV as is typically assumed.

  10. DETERMINATION OF TOTAL MERCURY IN FISH TISSUES USING PYROLYSIS ATOMIC ABSORPTION SPECTROMETRY WITH GOLD AMALGAMATION

    EPA Science Inventory

    A simple and rapid procedure for measuring total mercury in fish tissues is evaluated and
    compared with conventional techniques. Using an automated instrument incorporating combustion, preconcentration by amalgamation with gold, and atomic absorption spectrometry (AAS), mill...

  11. EPA Method 245.1: Determination of Mercury in Water by Cold Vapor Atomic Absorption Spectrometry

    EPA Pesticide Factsheets

    SAM lists this method for preparation and analysis of aqueous liquid and drinking water samples. This method will determine mercuric chloride and methoxyethylmercuric acetate as total mercury using cold vapor atomic absorption spectrometry.

  12. Determination of tin in poly(vinyl chloride) by atomic-absorption spectroscopy.

    PubMed

    Anwar, J; Marr, I L

    1982-10-01

    A simple procedure is described for the determination of tin in PVC by atomic-absorption spectroscopy with an air-hydrogen flame, after wet digestion of the sample with sulphuric acid and hydrogen peroxide.

  13. Novel xenon calibration scheme for two-photon absorption laser induced fluorescence of hydrogen

    NASA Astrophysics Data System (ADS)

    Elliott, Drew; Scime, Earl; Short, Zachary

    2016-11-01

    Two photon absorption laser induced fluorescence (TALIF) measurements of neutral hydrogen and its isotopes are typically calibrated by performing TALIF measurements on krypton with the same diagnostic system and using the known ratio of the absorption cross sections [K. Niemi et al., J. Phys. D 34, 2330 (2001)]. Here we present the measurements of a new calibration method based on a ground state xenon scheme for which the fluorescent emission wavelength is nearly identical to that of hydrogen, thereby eliminating chromatic effects in the collection optics and simplifying detector calibration. We determine that the ratio of the TALIF cross sections of xenon and hydrogen is 0.024 ± 0.001.

  14. Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

    NASA Technical Reports Server (NTRS)

    Meyer, Scott Andrew

    1995-01-01

    The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3x10(exp 17) and 9x10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

  15. Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

    NASA Technical Reports Server (NTRS)

    Meyer, Scott Andrew

    1995-01-01

    The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17) cm(exp -3). The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

  16. Vacuum Ultraviolet Absorption Measurements of Atomic Oxygen in a Shock Tube

    NASA Technical Reports Server (NTRS)

    Meyer, Scott Andrew

    1995-01-01

    The absorption of vacuum ultraviolet light by atomic oxygen has been measured in the Electric Arc-driven Shock Tube (EAST) Facility at NASA-Ames Research Center. This investigation demonstrates the instrumentation required to determine atomic oxygen concentrations from absorption measurements in impulse facilities. A shock wave dissociates molecular oxygen, producing a high temperature sample of atomic oxygen in the shock tube. A probe beam is generated with a Raman-shifted ArF excimer laser. By suitable tuning of the laser, absorption is measured over a range of wavelengths in the region of the atomic line at 130.49 nm. The line shape function is determined from measurements at atomic oxygen densities of 3 x 10(exp 17) and 9 x 10(exp 17)/cu cm. The broadening coefficient for resonance interactions is deduced from this data, and this value is in accord with available theoretical models.

  17. Two Photon Absorption Laser Induced Fluorescence for Neutral Hydrogen Profile Measurements

    SciTech Connect

    Scime, Earl E.

    2016-09-23

    The magnitude and spatial dependence of neutral density in magnetic confinement fusion experiments is a key physical parameter, particularly in the plasma edge. Modeling codes require precise measurements of the neutral density to calculate charge-exchange power losses and drag forces on rotating plasmas. However, direct measurements of the neutral density are problematic. In this work, we proposed to construct a laser-based diagnostic capable of providing spatially resolved measurements of the neutral density in the edge of plasma in the DIII-D tokamak. The diagnostic concept is based on two-photon absorption laser induced fluorescence (TALIF). By injecting two beams of 205 nm light (co or counter propagating), ground state hydrogen (or deuterium or tritium) can be excited from the n = 1 level to the n = 3 level at the location where the two beams intersect. Individually, the beams experience no absorption, and therefore have no difficulty penetrating even dense plasmas. After excitation, a fraction of the hydrogen atoms decay from the n = 3 level to the n = 2 level and emit photons at 656 nm (the Hα line). Calculations based on the results of previous TALIF experiments in magnetic fusion devices indicated that a laser pulse energy of approximately 3 mJ delivered in 5 ns would provide sufficient signal-to-noise for detection of the fluorescence. In collaboration with the DIII-D engineering staff and experts in plasma edge diagnostics for DIII-D from Oak Ridge National Laboratory (ORNL), WVU researchers designed a TALIF system capable of providing spatially resolved measurements of neutral deuterium densities in the DIII-D edge plasma. The laser systems were specified, purchased, and assembled at WVU. The TALIF system was tested on a low-power hydrogen discharge at WVU and the plan was to move the instrument to DIII-D for installation in collaboration with ORNL researchers. After budget cuts at DIII-D, the DIII-D facility declined to support

  18. Quantitation of DNA and RNA with Absorption and Fluorescence Spectroscopy.

    PubMed

    Gallagher, Sean R

    2017-02-02

    Quantitation of nucleic acids is a fundamental tool in molecular biology that requires accuracy, reliability, and the use of increasingly smaller sample volumes. This unit describes the traditional absorbance measurement at 260 nm and three more sensitive fluorescence techniques employing Hoechst 33258, ethidium bromide, and PicoGreen. The range of the assays covers 25 pg/ml to 50 µg/ml. Absorbance at 260 nm has an effective range from 1 to 50 µg/ml; Hoechst 33258 from 0.01 to 15 µg/ml; ethidium bromide from 0.1 to 10 µg/ml; and PicoGreen from 25 to 1000 pg/ml. © 2017 by John Wiley & Sons, Inc.

  19. Measurement of aluminum in neuronal tissues using electrothermal atomization atomic absorption spectrophotometry

    SciTech Connect

    Pierson, K.B.; Evenson, M.A.

    1986-07-01

    Studies characterizing aluminum complexes isolated from neuronal tissues require accurate and precise techniques for aluminum measurement. A solution of 0.01 M nitric acid containing 0.2% Triton X-100 was the optimal diluent for aluminum measurement under the experimental conditions used. Three National Bureau of Standards Standard Reference Materials (SRM) were digested, and the aluminum concentration of each was measured with a Perkin-Elmer 503 atomic absorption spectrophotometer equipped with a Perkin-Elmer HGA 2100 controller. The calculated detection limit of aluminum was 120 pg using 15-..mu..L sample injections (8 ..mu..g/L). Aluminum concentrations present in citrus leaves (SRM 1572), pine needles (SRM 1575), and tomato leaves (SRM 1573) were 100 +- 12 (certified value, 92 +- 15), 522 +- 45 (certified value, 454 +- 30), and 1273 +- 112 (provisional value, 1200) ..mu..g/g, respectively. The within- and between-day precision had coefficients of variation for citrus leaves, pine needles, and tomato leaves of 18 and 12%, 6.3 and 8.6%, and 3.7 and 8.7%, respectively. Aluminum absorbance was enhanced at high pH values and by zinc.

  20. Note: Measurement of saturable absorption by intense vacuum ultraviolet free electron laser using fluorescent material.

    PubMed

    Inubushi, Y; Yoneda, H; Higashiya, A; Ishikawa, T; Kimura, H; Kumagai, T; Morimoto, S; Nagasono, M; Ohashi, H; Sato, F; Tanaka, T; Togashi, T; Tono, K; Yabashi, M; Yamaguchi, Y; Kodama, R

    2010-03-01

    Advances in free electron lasers (FELs) which generate high energy photons are expected to open novel nonlinear optics in the x-ray and vacuum ultraviolet (VUV) regions. In this paper, we report a new method for performing VUV-FEL focusing experiments. A VUV-FEL was focused with Kirkpatrick-Baez optics on a multilayer target, which contains fused silica as a fluorescent material. By measuring the fluorescence, a 5.6x4.9 microm(2) focal spot was observed in situ. Fluorescence was used to measure the saturable absorption of VUV pulses in the tin layer. The transmission increases nonlinearly higher with increasing laser intensity.

  1. Double-well atom trap for fluorescence detection at the Heisenberg limit

    NASA Astrophysics Data System (ADS)

    Stroescu, Ion; Hume, David B.; Oberthaler, Markus K.

    2015-01-01

    We experimentally demonstrate an atom number detector capable of simultaneous detection of two mesoscopic ensembles with single-atom resolution. Such a sensitivity is a prerequisite for quantum metrology at a precision approaching the Heisenberg limit. Our system is based on fluorescence detection of atoms in a hybrid trap in which a dipole barrier divides a magneto-optical trap into two separated wells. We introduce a noise model describing the various sources contributing to the measurement error and report a limit of up to 500 atoms for single-atom resolution in the atom number difference.

  2. Small fluorescence-activating and absorption-shifting tag for tunable protein imaging in vivo

    PubMed Central

    Plamont, Marie-Aude; Billon-Denis, Emmanuelle; Maurin, Sylvie; Gauron, Carole; Pimenta, Frederico M.; Specht, Christian G.; Shi, Jian; Quérard, Jérôme; Pan, Buyan; Rossignol, Julien; Moncoq, Karine; Morellet, Nelly; Volovitch, Michel; Lescop, Ewen; Chen, Yong; Triller, Antoine; Vriz, Sophie; Le Saux, Thomas; Jullien, Ludovic; Gautier, Arnaud

    2016-01-01

    This paper presents Yellow Fluorescence-Activating and absorption-Shifting Tag (Y-FAST), a small monomeric protein tag, half as large as the green fluorescent protein, enabling fluorescent labeling of proteins in a reversible and specific manner through the reversible binding and activation of a cell-permeant and nontoxic fluorogenic ligand (a so-called fluorogen). A unique fluorogen activation mechanism based on two spectroscopic changes, increase of fluorescence quantum yield and absorption red shift, provides high labeling selectivity. Y-FAST was engineered from the 14-kDa photoactive yellow protein by directed evolution using yeast display and fluorescence-activated cell sorting. Y-FAST is as bright as common fluorescent proteins, exhibits good photostability, and allows the efficient labeling of proteins in various organelles and hosts. Upon fluorogen binding, fluorescence appears instantaneously, allowing monitoring of rapid processes in near real time. Y-FAST distinguishes itself from other tagging systems because the fluorogen binding is highly dynamic and fully reversible, which enables rapid labeling and unlabeling of proteins by addition and withdrawal of the fluorogen, opening new exciting prospects for the development of multiplexing imaging protocols based on sequential labeling. PMID:26711992

  3. Self-absorption Effects on Alpha-Induced Atmospheric Nitrogen Fluorescence Yield

    SciTech Connect

    Bachelor, Paula P.; Jordan, David V.; Harper, Warren W.; Cannon, Bret D.; Finn, Erin C.

    2009-12-01

    Nitrogen fluorescence induced by alpha, beta and gamma radiation can be used to detect the presence of radioactive contamination in the environment. Successful measurement of fluorescence yield involves a number of factors, including: known fluorescence signal rate during the measurement; the effective alpha spectrum of the radioactive sources used in the measurement; optical attenuation length of the fluorescence signal in air during the measurement; the absolute throughput of the instrumentation; calibration of the instrumentation; and radiation transport modeling of the "effective" array exposure rate given the spectrum of the alpha particles. Field testing of optical instrumentation was conducted to measure the nitrogen fluorescence yield from the alpha radiation generated from americium-241 (241Am) decay. The 241Am test sources were prepared by direct evaporation of ~1 mCi in nitric acid solution, and some solids were visible on the surface of the sources. A laboratory study was conducted with lower activities of 241Am to determine whether the presence of solids on the surface of the sources prepared both by direct evaporation and by electrodeposition onto stainless steel disks produced sufficient self-absorption to cause a decrease in expected fluorescence. Alpha spectroscopy was used to determine the apparent activity of the sources versus the known activity deposited on the surface. Results from the self-absorption laboratory studies were used to correct the activity values in the model and calculate the nitrogen fluorescence generated by the 241Am during the field experiments.

  4. Small fluorescence-activating and absorption-shifting tag for tunable protein imaging in vivo.

    PubMed

    Plamont, Marie-Aude; Billon-Denis, Emmanuelle; Maurin, Sylvie; Gauron, Carole; Pimenta, Frederico M; Specht, Christian G; Shi, Jian; Quérard, Jérôme; Pan, Buyan; Rossignol, Julien; Moncoq, Karine; Morellet, Nelly; Volovitch, Michel; Lescop, Ewen; Chen, Yong; Triller, Antoine; Vriz, Sophie; Le Saux, Thomas; Jullien, Ludovic; Gautier, Arnaud

    2016-01-19

    This paper presents Yellow Fluorescence-Activating and absorption-Shifting Tag (Y-FAST), a small monomeric protein tag, half as large as the green fluorescent protein, enabling fluorescent labeling of proteins in a reversible and specific manner through the reversible binding and activation of a cell-permeant and nontoxic fluorogenic ligand (a so-called fluorogen). A unique fluorogen activation mechanism based on two spectroscopic changes, increase of fluorescence quantum yield and absorption red shift, provides high labeling selectivity. Y-FAST was engineered from the 14-kDa photoactive yellow protein by directed evolution using yeast display and fluorescence-activated cell sorting. Y-FAST is as bright as common fluorescent proteins, exhibits good photostability, and allows the efficient labeling of proteins in various organelles and hosts. Upon fluorogen binding, fluorescence appears instantaneously, allowing monitoring of rapid processes in near real time. Y-FAST distinguishes itself from other tagging systems because the fluorogen binding is highly dynamic and fully reversible, which enables rapid labeling and unlabeling of proteins by addition and withdrawal of the fluorogen, opening new exciting prospects for the development of multiplexing imaging protocols based on sequential labeling.

  5. Fluorescence emission of Ca-atom from photodissociated Ca2 in Ar doped helium droplets. II. Theoretical.

    PubMed

    Hernando, A; Masson, A; Briant, M; Mestdagh, J-M; Gaveau, M-A; Halberstadt, N

    2012-11-14

    The stability of the ground or excited state calcium atom in an argon-doped helium droplet has been investigated using an extension of the helium density functional method to treat clusters. This work was motivated by the experimental study presented in a companion paper, hereafter called Paper I [A. Masson, M. Briant, J. M. Mestdagh, M. A. Gaveau, A. Hernando, and N. Halberstadt, J. Chem. Phys. 137, 184310 (2012)], which investigated Ca(2) photodissociation in an argon-doped helium droplet and the nature of the fluorescent species. It is found that one single argon atom is sufficient to bring the calcium atom inside the droplet, for droplets of over 200 helium atoms. The absorption and emission spectra of CaAr(M) (M = 0-7) clusters have been simulated using the recently developed density sampling method to describe the influence of the helium environment. Absorption spectra exhibit broad, double bands that are significantly blueshifted with respect to the calcium atomic line. The emission spectra are less broad and redshifted with respect to the calcium resonance line. The shifts are found to be additive only for M ≤ 2, because only the first two argon atoms are located in equivalent positions around the calcium p orbital. This finding gives a justification for the fit presented in the companion paper, which uses the observed shifts in the emission spectra as a function of argon pressure to deduce the shifts as a function of the number of argon atoms present in the cluster. An analysis of this fit is presented here, based on the calculated shifts. It is concluded that the emitting species following Ca(2) photodissociation in an argon-doped droplet in Paper I could be Ca∗Ar(M) in a partly evaporated droplet where less than 200 helium atoms remain.

  6. Disentangling atomic-layer-specific x-ray absorption spectra by Auger electron diffraction spectroscopy

    NASA Astrophysics Data System (ADS)

    Matsui, Fumihiko; Matsushita, Tomohiro; Kato, Yukako; Hashimoto, Mie; Daimon, Hiroshi

    2009-11-01

    In order to investigate the electronic and magnetic structures of each atomic layer at subsurface, we have proposed a new method, Auger electron diffraction spectroscopy, which is the combination of x-ray absorption spectroscopy (XAS) and Auger electron diffraction (AED) techniques. We have measured a series of Ni LMM AED patterns of the Ni film grown on Cu(001) surface for various thicknesses. Then we deduced a set of atomic-layer-specific AED patterns in a numerical way. Furthermore, we developed an algorithm to disentangle XANES spectra from different atomic layers using these atomic-layer-specific AED patterns. Surface and subsurface core level shift were determined for each atomic layer.

  7. Absorption Spectrum of the Green Fluorescent Protein Chromophore Anion In Vacuo

    NASA Astrophysics Data System (ADS)

    Nielsen, S. B.; Lapierre, A.; Andersen, J. U.; Pedersen, U. V.; Tomita, S.; Andersen, L. H.

    2001-11-01

    A sensitive photoabsorption technique for studies of gas-phase biomolecules has been used at the ELISA electrostatic heavy-ion storage ring. We show that the anion form of the chromophore of the green fluorescent protein in vacuo has an absorption maximum at 479 nm, which coincides with one of the two absorption peaks of the protein. Its absorption characteristics are therefore ascribed to intrinsic chemical properties of the chromophore. Evidently, the special β-can structure of the protein provides shielding of the chromophore from the surroundings without significantly changing the electronic structure of the chromophore through interactions with amino acid side chains.

  8. Atomic structure of machined semiconducting chips: An x-ray absorption spectroscopy study

    SciTech Connect

    Paesler, M.; Sayers, D.

    1988-12-01

    X-ray absorption spectroscopy (XAS) has been used to examine the atomic structure of chips of germanium that were produced by single point diamond machining. It is demonstrated that although the local (nearest neighbor) atomic structure is experimentally quite similar to that of single crystal specimens information from more distant atoms indicates the presence of considerable stress. An outline of the technique is given and the strength of XAS in studying the machining process is demonstrated.

  9. Absorption and fluorescence spectra of poly(p-phenylenevinylene) (PPV) oligomers: an ab initio simulation.

    PubMed

    Cardozo, Thiago M; Aquino, Adélia J A; Barbatti, Mario; Borges, Itamar; Lischka, Hans

    2015-03-05

    The absorption and fluorescence spectra of poly(p-phenylenevinylene) (PPV) oligomers with up to seven repeat units were theoretically investigated using the algebraic diagrammatic construction method to second order, ADC(2), combined with the resolution-of-the-identity (RI) approach. The ground and first excited state geometries of the oligomers were fully optimized. Vertical excitation energies and oscillator strengths of the first four transitions were computed. The vibrational broadening of the absorption and fluorescence spectra was studied using a semiclassical nuclear ensemble method. After correcting for basis set and solvent effects, we achieved a balanced description of the absorption and fluorescence spectra by means of the ADC(2) approach. This fact is documented by the computed Stokes shift along the PPV series, which is in good agreement with the experimental values. The experimentally observed band width of the UV absorption and fluorescence spectra is well reproduced by the present simulations showing that the nuclear ensemble generated should be well suitable for consecutive surface hopping dynamics simulations.

  10. Fluorescence, Absorption, and Excitation Spectra of Polycyclic Aromatic Hydrocarbons as a Tool for Quantitative Analysis

    ERIC Educational Resources Information Center

    Rivera-Figueroa, A. M.; Ramazan, K. A.; Finlayson-Pitts, B. J.

    2004-01-01

    A quantitative and qualitative study of the interplay between absorption, fluorescence, and excitation spectra of pollutants called polycyclic aromatic hydrocarbons (PAHs) is conducted. The study of five PAH displays the correlation of the above-mentioned properties along with the associated molecular changes.

  11. Saturation of Energy Levels in Analytical Atomic Fluorescence Spectrometry. II. Experimental.

    DTIC Science & Technology

    1981-01-30

    RESEARCH Contract N14-76-C-0838 Task Ao. NR 051-622 TECHNICAL REPORT NO. 34 SATURATION OF ENERGY LEVELS IN ANALYTICAL ATOMIC FLUORESCENCE SPECTROMETRY II...an assumption which is valid only if the daral o’l of 111, cxcilIatio n pulse is mucl ) longer than the fluorescence life- time of the tjaii!,ition

  12. Determination of cadmium in biodiesel using microemulsion and electrothermal atomization atomic absorption spectrometry.

    PubMed

    Lima, Adriana S; Silva, Deise G; Teixeira, Leonardo S G

    2015-01-01

    This work aimed to prepare biodiesel microemulsions for the subsequent quantification of cadmium via graphite furnace atomic absorption spectrometry (GFAAS). The biodiesel samples were prepared using n-propanol as an emulsifier, 10% (v/v) nitric acid as the aqueous phase, and biodiesel. Pseudoternary phase diagrams were constructed to determine the microemulsion region with the specified components. The optimized conditions for microemulsion formation were 57.6% (v/v) n-propanol, 21.2% (v/v) biodiesel, and 21.2% (v/v) nitric acid solution. The stability of the microemulsified system was investigated using aqueous and organic standards, and the system was found to be stable for at least 240 min. The applied pyrolysis and atomization temperatures were 800 and 2000 °C, respectively, and 5 μg of aluminum was used as the chemical modifier. The obtained limits of detection and quantification were 0.2 and 0.5 μg kg(-1), respectively, and the characteristic mass was 1.6 pg. The precision, expressed as the relative standard deviation (% R.S.D., n = 10), was 2.5% for a sample with a cadmium concentration of 6.5 μg kg(-1). The accuracy was determined from addition and recovery experiments, with results varying from 93 to 108% recovery. This study demonstrates that the proposed method based on the use of a microemulsion formation in sample preparation can be applied as an efficient alternative for the determination of cadmium in biodiesel by GFAAS. Cadmium determination in biodiesel samples of different origins (soybean, corn, cotton, and sunflower) was evaluated after acid digestion using the inductively coupled plasma-mass spectrometry (ICP-MS) technique, and the obtained results were compared to the results obtained using the proposed method. The paired t test (95% confidence level) did not show significant differences. The concentrations of cadmium found ranged from 5.3 to 8.0 μg kg(-1).

  13. Dielectric barrier discharges with steep voltage rise: mapping of atomic nitrogen in single filaments measured by laser-induced fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Lukas, C.; Spaan, M.; Schulz-von der Gathen, V.; Thomson, M.; Wegst, R.; Döbele, H. F.; Neiger, M.

    2001-08-01

    Space and time resolved relative atomic density distributions of nitrogen have been measured for the first time at a single filament within a dielectric barrier discharge (DBD) reactor with submillimetre radial dimensions. Two-photon-Absorption Laser-Induced Fluorescence (TALIF) spectroscopy of atomic nitrogen using radiation at λ = 206.7 nm is applied to a DBD with fast rising voltage amplitudes. The decay time of the atomic nitrogen density depends strongly on the position within the discharge and the distance from the dielectric where the lifetime is maximum. Admixed oxygen leads to an increase of the N density decay by an order of magnitude even at small fractions.

  14. Targeting Inaccurate Atomic Data in the Eta Car Ejecta Absorption

    NASA Technical Reports Server (NTRS)

    Nielsen, K. E.; Kober, G. Vieira; Gull, T. R.; Blackwell-Whitehead, R.; Nilsson, H.

    2006-01-01

    The input from the laboratory spectroscopist community has on many occasions helped the analysis of the eta Car spectrum. Our analysis has targeted spectra where improved wavelengths and oscillator strengths are needed. We will demonstrate how experimentally derived atomic data have improved our spectral analysis, and illuminate where more work still is needed.

  15. Gold volatile species atomization and preconcentration in quartz devices for atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Arslan, Yasin; Musil, Stanislav; Matoušek, Tomáš; Kratzer, Jan; Dědina, Jiří

    2015-01-01

    The on-line atomization of gold volatile species was studied and the results were compared with thermodynamic calculations in several quartz atomizers, namely: diffusion flame, flame-in-gas-shield, flame-in-plain-tube, externally heated T-tube and externally heated flame-in-T-tube. Atomization mechanism in the explored devices is proposed, where volatile species are converted to thermodynamically stable AuH at elevated temperature over 500 °C and then atomized by an interaction with a cloud of hydrogen radicals. Because of its inherent simplicity and robustness, diffusion flame was employed as a reference atomizer. It yielded atomization efficiency of 70 to 100% and a very good long time reproducibility of peak area sensitivity: 1.6 to 1.8 s μg- 1. Six and eleven times higher sensitivity, respectively, was provided by atomizers with longer light paths in the observation volume, i.e. externally heated T-tube and externally heated flame-in-T-tube. The latter one, offering limit of detection below 0.01 μg ml- 1, appeared as the most prospective for on-line atomization. Insight into the mechanism of atomization of gold volatile species, into the fate of free atoms and into subsequent analyte transfer allowed to assess possibilities of in-atomizer preconcentration of gold volatile species: it is unfeasible with quartz atomizers but a sapphire tube atomizer could be useful in this respect.

  16. Experimental recovery of intrinsic fluorescence and fluorophore concentration in the presence of hemoglobin: spectral effect of scattering and absorption on fluorescence

    NASA Astrophysics Data System (ADS)

    Du Le, Vinh Nguyen; Patterson, Michael S.; Farrell, Thomas J.; Hayward, Joseph E.; Fang, Qiyin

    2015-12-01

    The ability to recover the intrinsic fluorescence of biological fluorophores is crucial to accurately identify the fluorophores and quantify their concentrations in the media. Although some studies have successfully retrieved the fluorescence spectral shape of known fluorophores, the techniques usually came with heavy computation costs and did not apply for strongly absorptive media, and the intrinsic fluorescence intensity and fluorophore concentration were not recovered. In this communication, an experimental approach was presented to recover intrinsic fluorescence and concentration of fluorescein in the presence of hemoglobin (Hb). The results indicated that the method was efficient in recovering the intrinsic fluorescence peak and fluorophore concentration with an error of 3% and 10%, respectively. The results also suggested that chromophores with irregular absorption spectra (e.g., Hb) have more profound effects on fluorescence spectral shape than chromophores with monotonic absorption and scattering spectra (e.g., black India ink and polystyrene microspheres).

  17. Experimental recovery of intrinsic fluorescence and fluorophore concentration in the presence of hemoglobin: spectral effect of scattering and absorption on fluorescence.

    PubMed

    Du Le, Vinh Nguyen; Patterson, Michael S; Farrell, Thomas J; Hayward, Joseph E; Fang, Qiyin

    2015-01-01

    The ability to recover the intrinsic fluorescence of biological fluorophores is crucial to accurately identify the fluorophores and quantify their concentrations in the media. Although some studies have successfully retrieved the fluorescence spectral shape of known fluorophores, the techniques usually came with heavy computation costs and did not apply for strongly absorptive media, and the intrinsic fluorescence intensity and fluorophore concentration were not recovered. In this communication, an experimental approach was presented to recover intrinsic fluorescence and concentration of fluorescein in the presence of hemoglobin (Hb). The results indicated that the method was efficient in recovering the intrinsic fluorescence peak and fluorophore concentration with an error of 3% and 10%, respectively. The results also suggested that chromophores with irregular absorption spectra (e.g., Hb) have more profound effects on fluorescence spectral shape than chromophores with monotonic absorption and scattering spectra (e.g., black India ink and polystyrene microspheres).

  18. A new near-infrared absorption and fluorescent probe based on bombesin for molecular imaging

    NASA Astrophysics Data System (ADS)

    Kujala, Naresh; Zhai, Huifang; Smith, Charles; Prasanphanich, Adam; Sieckman, Gary; Hoffman, Timothy; Volkert, Wynn; Ma, Lixin; Yu, Ping

    2009-02-01

    We have developed a series of new dye bombesin conjugates for site-specific absorption and fluorescence imaging of human prostate and breast cancers. Bombesin (BBN), an amphibian analog to the endogenous ligand, binds to the gastrin releasing peptide (GRP) receptors with high specificity and affinity. Previously, we developed an Alexa Fluor 680-GGG-BBN peptide conjugate which demonstrated high binding affinity and specificity for breast cancer cells in the in vitro and in vivo tests (Ref: Ma et al., Molecular Imaging, vol. 6, no. 3, 2007: 171-180). This probe can not be used as an absorption probe in near-infrared imaging because its absorption peak is in the visible wavelength range. In addition, site specific longer wavelength fluorescent probe is desired for in vivo molecular imaging because long wavelength photons penetrate deeper into tissue. The new absorption and fluorescent probe we developed is based on the last eight-residues of BBN, -Q-W-A-V-G-H-L-M-(NH2), and labeled with AlexaFluor750 through a chemical linker, beta-alanine. The new probe, Alexa Fluor 750-BetaAla-BBN(7-14)NH2, exhibits optimal pharmacokinetics for specific targeting and optical imaging of the GRP receptor over-expressing cancer cells. Absorption spectrum has been measured and showed absorption peaks at 690nm, 720nm and 735nm. Fluorescent band is located at 755nm. In vitro and in vivo investigations have demonstrated the effectiveness of the new conjugates to specifically target human cancer cells overexpressing GRP receptors and tumor xenografts in severely compromised immunodeficient mouse model.

  19. Atomic absorption determination of tin in foods: collaborative study.

    PubMed

    Elkins, E R; Sulek, A

    1979-09-01

    Samples of green beans, applesauce, and a fruit juice were fortified with tin at 3 levels. Collaborators were asked to digest the samples, using HNO3-H2SO4, add methanol to enhance the absorption signal, and aspirate directly, using a nitrous oxide-acetylene flame. Results were received from 8 laboratories including 4 from Europe. However, only 6 laboratories used the prescribed methodology. All results were considered acceptable. The method has been adopted as interim official first action.

  20. Absorption of infrared radiation by electrons in the field of a neutral hydrogen atom

    NASA Technical Reports Server (NTRS)

    Stallcop, J. R.

    1974-01-01

    An analytical expression for the absorption coefficient is developed from a relationship between the cross-section for inverse bremsstrahlung absorption and the cross-section for electron-atom momentum transfer; it is accurate for those photon frequencies v and temperatures such that hv/kT is small. The determination of the absorption of infrared radiation by free-free transitions of the negative hydrogen ion has been extended to higher temperatures. A simple analytical expression for the absorption coefficient has been derived.

  1. Methylmercury determination using a hyphenated high performance liquid chromatography ultraviolet cold vapor multipath atomic absorption spectrometry system

    NASA Astrophysics Data System (ADS)

    Campos, Reinaldo C.; Gonçalves, Rodrigo A.; Brandão, Geisamanda P.; Azevedo, Marlo S.; Oliveira, Fabiana; Wasserman, Julio

    2009-06-01

    The present work investigates the use of a multipath cell atomic absorption mercury detector for mercury speciation analysis in a hyphenated high performance liquid chromatography assembly. The multipath absorption cell multiplies the optical path while energy losses are compensated by a very intense primary source. Zeeman-effect background correction compensates for non-specific absorption. For the separation step, the mobile phase consisted in a 0.010% m/v mercaptoethanol solution in 5% methanol (pH = 5), a C 18 column was used as stationary phase, and post column treatment was performed by UV irradiation (60 °C, 13 W). The eluate was then merged with 3 mol L - 1 HCl, reduction was performed by a NaBH 4 solution, and the Hg vapor formed was separated at the gas-liquid separator and carried through a desiccant membrane to the detector. The detector was easily attached to the system, since an external gas flow to the gas-liquid separator was provided. A multivariate approach was used to optimize the procedure and peak area was used for measurement. Instrumental limits of detection of 0.05 µg L - 1 were obtained for ionic (Hg 2+) and HgCH 3+, for an injection volume of 200 µL. The multipath atomic absorption spectrometer proved to be a competitive mercury detector in hyphenated systems in relation to the most commonly used atomic fluorescence and inductively coupled plasma mass spectrometric detectors. Preliminary application studies were performed for the determination of methyl mercury in sediments.

  2. Optical and structural properties of plasma-treated Cordyceps bassiana spores as studied by circular dichroism, absorption, and fluorescence spectroscopy

    SciTech Connect

    Lee, Geon Joon Sim, Geon Bo; Choi, Eun Ha; Kim, Jun Young; Jang, Siun; Kim, Seong Hwan

    2015-01-14

    To understand the killing mechanism of fungal spores by plasma treatment, the optical, structural, and biological properties of the insect pathogenic fungus Cordyceps bassiana spores were studied. A nonthermal atmospheric-pressure plasma jet (APPJ) was used to treat the spores in aqueous solution. Optical emission spectra of the APPJ acquired in air indicated emission peaks corresponding to hydroxyl radicals and atomic oxygen. When the APPJ entered the aqueous solution, additional reactive species were derived from the interaction of plasma radicals with the aqueous solution. Fluorescence and absorption spectroscopy confirmed the generation of hydroxyl radicals and hydrogen peroxide in the plasma-activated water (PAW). Spore counting showed that plasma treatment significantly reduced spore viability. Absorption spectroscopy, circular dichroism (CD) spectroscopy, and agarose gel electrophoresis of the DNA extracted from plasma-treated spores showed a reduction in spore DNA content. The magnitude of the dip in the CD spectrum was lower in the plasma-treated spores than in the control, indicating that plasma treatment causes structural modifications and/or damage to cellular components. Tryptophan fluorescence intensity was lower in the plasma-treated spores than in the control, suggesting that plasma treatment modified cell wall proteins. Changes in spore viability and DNA content were attributed to structural modification of the cell wall by reactive species coming from the APPJ and the PAW. Our results provided evidence that the plasma radicals and the derived reactive species play critical roles in fungal spore inactivation.

  3. Optical and structural properties of plasma-treated Cordyceps bassiana spores as studied by circular dichroism, absorption, and fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Lee, Geon Joon; Sim, Geon Bo; Choi, Eun Ha; Kwon, Young-Wan; Kim, Jun Young; Jang, Siun; Kim, Seong Hwan

    2015-01-01

    To understand the killing mechanism of fungal spores by plasma treatment, the optical, structural, and biological properties of the insect pathogenic fungus Cordyceps bassiana spores were studied. A nonthermal atmospheric-pressure plasma jet (APPJ) was used to treat the spores in aqueous solution. Optical emission spectra of the APPJ acquired in air indicated emission peaks corresponding to hydroxyl radicals and atomic oxygen. When the APPJ entered the aqueous solution, additional reactive species were derived from the interaction of plasma radicals with the aqueous solution. Fluorescence and absorption spectroscopy confirmed the generation of hydroxyl radicals and hydrogen peroxide in the plasma-activated water (PAW). Spore counting showed that plasma treatment significantly reduced spore viability. Absorption spectroscopy, circular dichroism (CD) spectroscopy, and agarose gel electrophoresis of the DNA extracted from plasma-treated spores showed a reduction in spore DNA content. The magnitude of the dip in the CD spectrum was lower in the plasma-treated spores than in the control, indicating that plasma treatment causes structural modifications and/or damage to cellular components. Tryptophan fluorescence intensity was lower in the plasma-treated spores than in the control, suggesting that plasma treatment modified cell wall proteins. Changes in spore viability and DNA content were attributed to structural modification of the cell wall by reactive species coming from the APPJ and the PAW. Our results provided evidence that the plasma radicals and the derived reactive species play critical roles in fungal spore inactivation.

  4. Nearest-neighbor detection of atoms in a 1D optical lattice by fluorescence imaging.

    PubMed

    Karski, M; Förster, L; Choi, J M; Alt, W; Widera, A; Meschede, D

    2009-02-06

    We overcome the diffraction limit in fluorescence imaging of neutral atoms in a sparsely filled one-dimensional optical lattice. At a periodicity of 433 nm, we reliably infer the separation of two atoms down to nearest neighbors. We observe light induced losses of atoms occupying the same lattice site, while for atoms in adjacent lattice sites, no losses due to light induced interactions occur. Our method points towards characterization of correlated quantum states in optical lattice systems with filling factors of up to one atom per lattice site.

  5. Flameless Atomic Absorption Spectroscopy: Effects of Nitrates and Sulfates.

    DTIC Science & Technology

    1980-05-01

    oxide by graphite followed by sublimation of the metal. Frech and Cedergren investigated high temperature equilibria in graphite furnace atomizers. 1 4...Acta, 72, 49 (1974). 13. R.E. Sturgeon, C.L. Chakrabarti, and C.H. Langford, Anal. Chem., 48, 1792 (1976). 14. W. Frech and A. Cedergren , Anal. Chim...Acta, 82, 83 (1976). 15. W. Frech, Anal. Chim. Acta, 77, 43 (1975). 16. W. Frech and A. Cedergren , Anal. Chim. Acta, 88, 57 (1977). CHAPTER III

  6. Resonance fluorescence of a cold atom in a high-finesse resonator

    SciTech Connect

    Bienert, Marc; Torres, J. Mauricio; Zippilli, Stefano; Morigi, Giovanna

    2007-07-15

    We study the spectra of emission of a system composed by an atom, tightly confined inside a high-finesse resonator, when the atom is driven by a laser and is at steady state of the cooling dynamics induced by laser and cavity fields. In general, the spectrum of resonance fluorescence and the spectrum at the cavity output contain complementary information about the dynamics undergone by the system. In certain parameter regimes, quantum interference effects between the scattering processes induced by cavity and laser fields lead to the selective suppression of features of the resonance fluorescence spectrum, which are otherwise visible in the spectrum of laser-cooled atoms in free space.

  7. UV absorption and fluorescence properties of gas-phase p-difluorobenzene

    NASA Astrophysics Data System (ADS)

    Benzler, Thorsten; Dreier, Thomas; Schulz, Christof

    2017-01-01

    1,4-Difluorobenzene ( p-DFB) is a promising aromatic tracer for determining concentration, temperature, and O2 partial pressure in mixing gas flows based on laser-induced fluorescence (LIF). Signal quantification requires the knowledge of absorption and fluorescence properties as a function of environmental conditions. We report absorption and fluorescence spectra as well as fluorescence lifetimes of p-DFB in the temperature, pressure, and oxygen partial pressure range that is relevant for many applications including internal combustion engines. The UV absorption cross section, investigated between 296 and 675 K, has a peak value close to 266 nm and decreases with temperature, while still exceeding other single-ring aromatics. Time-resolved fluorescence spectra were recorded after picosecond laser excitation at 266 nm as a function of temperature (296-1180 K), pressure (1-10 bar), and O2 partial pressure (0-210 mbar) using a streak camera (temporal resolution 50 ps) coupled to a spectrometer. The fluorescence spectra red-shift ( 2 nm/100 K) and broaden (increase in full width at half maximum by 58% in the investigated temperature range) with temperature. In N2 as bath gas (1 bar), the fluorescence lifetime τ eff decreases with temperature by a factor of about 20 (from 7 ns at 298 K down to 0.32 ns at 1180 K), while at 8 bar the shortest lifetime at 975 K is 0.4 ns. A noticeable pressure dependence (i.e., reduced τ eff) is only visible at 675 K and above. Quenching of p-DFB LIF by O2 (for partial pressures up to 210 mbar) shortens the fluorescence lifetime significantly at room temperature (by a factor of 8), but much less at higher temperatures (by a factor of 1.8 at 970 K). For fixed O2 partial pressures (52 mbar and above), τ eff shows a plateau region with temperature which shifts toward higher temperatures at the higher O2 partial pressures. O2 quenching is less prominent for p-DFB compared to other aromatic compounds investigated so far. The temperature

  8. Quantitative fluorescence spectroscopy in turbid media: a practical solution to the problem of scattering and absorption.

    PubMed

    Chen, Yao; Chen, Zeng-Ping; Yang, Jing; Jin, Jing-Wen; Zhang, Juan; Yu, Ru-Qin

    2013-02-19

    The presence of practically unavoidable scatterers and background absorbers in turbid media such as biological tissue or cell suspensions can significantly distort the shape and intensity of fluorescence spectra of fluorophores and, hence, greatly hinder the in situ quantitative determination of fluorophores in turbid media. In this contribution, a quantitative fluorescence model (QFM) was proposed to explicitly model the effects of the scattering and absorption on fluorescence measurements. On the basis of the proposed model, a calibration strategy was developed to remove the detrimental effects of scattering and absorption and, hence, realize accurate quantitative analysis of fluorophores in turbid media. A proof-of-concept model system, the determination of free Ca(2+) in turbid media using Fura-2, was utilized to evaluate the performance of the proposed method. Experimental results showed that QFM can provide quite precise concentration predictions for free Ca(2+) in turbid media with an average relative error of about 7%, probably the best results ever achieved for turbid media without the use of advanced optical technologies. QFM has not only good performance but also simplicity of implementation. It does not require characterization of the light scattering properties of turbid media, provided that the light scattering and absorption properties of the test samples are reasonably close to those of the calibration samples. QFM can be developed and extended in many application areas such as ratiometric fluorescent sensors for quantitative live cell imaging.

  9. In situ phytoplankton absorption, fluorescence emission, and particulate backscattering spectra determined from reflectance

    NASA Technical Reports Server (NTRS)

    Roesler, Collin S.; Pery, Mary Jane

    1995-01-01

    An inverse model was developed to extract the absortion and scattering (elastic and inelastic) properties of oceanic constituents from surface spectral reflectance measurements. In particular, phytoplankton spectral absorption coefficients, solar-stimulated chlorophyll a fluorescence spectra, and particle backscattering spectra were modeled. The model was tested on 35 reflectance spectra obtained from irradiance measurements in optically diverse ocean waters (0.07 to 25.35 mg/cu m range in surface chlorophyll a concentrations). The universality of the model was demonstrated by the accurate estimation of the spectral phytoplankton absorption coefficents over a range of 3 orders of magnitude (rho = 0.94 at 500 nm). Under most oceanic conditions (chlorophyll a less than 3 mg/cu m) the percent difference between measured and modeled phytoplankton absorption coefficents was less than 35%. Spectral variations in measured phytoplankton absorption spectra were well predicted by the inverse model. Modeled volume fluorescence was weakly correlated with measured chl a; fluorescence quantum yield varied from 0.008 to 0.09 as a function of environment and incident irradiance. Modeled particle backscattering coefficients were linearly related to total particle cross section over a twentyfold range in backscattering coefficents (rho = 0.996, n = 12).

  10. Americium characterization by X-ray fluorescence and absorption spectroscopy in plutonium uranium mixed oxide

    SciTech Connect

    Degueldre, Claude Cozzo, Cedric; Martin, Matthias; Grolimund, Daniel; Mieszczynski, Cyprian

    2013-06-01

    Plutonium uranium mixed oxide (MOX) fuels are currently used in nuclear reactors. The actinides in these fuels need to be analyzed after irradiation for assessing their behaviour with regard to their environment and the coolant. In this work the study of the atomic structure and next-neighbour environment of Am in the (Pu,U)O₂ lattice in an irradiated (60 MW d kg⁻¹) MOX sample was performed employing micro-X-ray fluorescence (µ-XRF) and micro-X-ray absorption fine structure (µ-XAFS) spectroscopy. The chemical bonds, valences and stoichiometry of Am (~0.66 wt%) are determined from the experimental data gained for the irradiated fuel material examined in its peripheral zone (rim) of the fuel. In the irradiated sample Am builds up as Am³⁺ species within an [AmO₈]¹³⁻ coordination environment (e.g. >90%) and no (<10%) Am(IV) or (V) can be detected in the rim zone. The occurrence of americium dioxide is avoided by the redox buffering activity of the uranium dioxide matrix. - Graphical abstract: Americium LIII XAFS spectra recorded for the irradiated MOX sub-sample in the rim zone for a 300 μm×300 μm beam size area investigated over six scans of 4 h. The records remain constant during multi-scan. The analysis of the XAFS signal shows that Am is found as trivalent in the UO₂ matrix. This analytical work shall open the door of very challenging analysis (speciation of fission product and actinides) in irradiated nuclear fuels. - Highlights: • Americium was characterized by microX-ray absorption spectroscopy in irradiated MOX fuel. • The americium redox state as determined from XAS data of irradiated fuel material was Am(III). • In the sample, the Am³⁺ face an AmO₈¹³⁻coordination environment in the (Pu,U)O₂ matrix. • The americium dioxide is reduced by the uranium dioxide matrix.

  11. Bias and uncertainty in the absorption emission measurement of atomic sodium density in the SSME exit plane

    NASA Technical Reports Server (NTRS)

    Bauman, Leslie E.

    1990-01-01

    The measurement of atomic sodium concentration in the TTB 019 firing of April 1990 is significant in that it represents the first measurement of density at the exit plane of the space shuttle main engine. The knowledge of the sodium density, combined with the certainty that the exit plane of the plume is optically thin at the sodium D-line wavelengths, provides essential information for evaluation of diagnostic techniques using sodium atoms, such as resonant Doppler velocimetry for temperature, pressure, and velocity through high resolution fluorescent lineshape analysis. The technique used for the sodium atom line transmission (SALT) measurements is that of resonant absorption emission using a hollow cathode lamp as the reference source. Through the use of two-dimensional kinetic (TDK) predictions of temperature and density for the flight engine case and radiative transfer calculations, this line-of-sight spectrally integrated transmission indicates a sodium atom concentration, i.e., mole fraction, of 0.91e-10. The subject of this paper is the assumptions and measurement uncertainties tied into the calculation. Because of the narrow shape of the source emission, the uncertainties in the absorption profile could introduce considerable bias in the measurement. The following were investigated: (1) the inclusion of hyperfine splitting of the D-lines in the calculation; (2) the use of the flight engine predictions of plume temperature and density versus those for the large throat engine; (3) the assumption of a Gaussian, i.e., Doppler, distribution for the source radiance with a temperature of 400 K; (4) the use of atomic collisional shift and width values for the work by Jongerius; and (5) a Doppler shift for a 7 degree outward velocity vector at the plume edge. Also included in the study was the bias introduced by an uncertainty in the measurement of the D1/D2 line ratio in the source.

  12. Optical sensor instrumentation using absorption- and fluorescence-based capillary waveguide optrodes

    NASA Astrophysics Data System (ADS)

    Weigl, Bernhard H.; Draxler, Sonja; Kieslinger, Dietmar; Lehmann, H.; Trettnak, Wolfgang; Wolfbeis, Otto S.; Lippitsch, Max E.

    1995-09-01

    An analytical instrument comprising absorption- and fluorescence-based capillary waveguide optrodes (CWOs) is described. Glass capillaries with a chemically sensitive coating on the inner surface are used for optical chemical sensing in gaseous and liquid samples. In case of absorption-based CWOs, light from a LED is coupled into and out of the capillary under a defined angle via a rigid waveguide and an immersion coupler. The coated glass capillary forms an inhomogeneous waveguide, in which the light is guided in both the glass and the coating. The portion of the light which is absorbed in the chemically sensitive coating is proportional to a chemcial concentration or activity. This principle is demonstrated with a pCO2-sensitive inner coating. Typical relative light intensity signal changes with this type of optical interrogation are 98%, with an active capillary length of 10 mm. For fluorescence- based CWOs, the excitation light from an LED is coupled diffusely into the glass capillary and the optical sensor layer. A major portion of the excited fluorescence light is then collected within the coated capillary, and guided to the photodiode, which is located on the distal end of the capillary waveguide. Hereby, the excitation light is separated very efficiently from the fluorescent light. As an example, a CWO for pO2 is described. By applying this optical geometry, it was possible to utilize fluorescence decay time of the sensor layer as the transducer signal even when using solid state components (LEDs and photodiodes).

  13. Determination of antimony by using tungsten trap atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Titretir, Serap; Kendüzler, Erdal; Arslan, Yasin; Kula, İbrahim; Bakırdere, Sezgin; Ataman, O. Yavuz.

    2008-08-01

    An electrically heated tungsten coil was used as a trap in the determination of antimony. The technique consists of three steps. Initially, SbH 3 is formed by hydride generation procedure; then the analyte species in vapor form are transported to W-coil trap heated at 370 °C. Following the preconcentration step, the trap is heated to 895 °C; analyte species are revolatilized and transported to the flame-heated quartz atom cell where atomization and the formation of signal take place. The experimental parameters were optimized both for trap and no-trap studies. The most important experimental parameters are concentrations of HCl and NaBH 4 solutions, H 2 and Ar gas flow rates, and collection and revolatilization temperatures of W-coil. Accuracy was tested using a certified reference material, waste water EU-L-1. Limit of detection for the system is 16 ng l - 1 using a sample of 36 ml collected in 4.0 min. Enhancement factor in sensitivity was 17.

  14. Study of the analytical methods for iron determination in complex organic liquids by atomic absorption spectrometry

    SciTech Connect

    Torre, M.; Gonzalez, M.C.; Jimenez, O.; Rodriquez, A.R. )

    1990-01-01

    In the determination of iron in complex organic liquids by atomic absorption spectrometry (A.A.S.), methods of sample preparation, such as dilution with an organic solvent and sample pretreatment to destroy organic material, are investigated. Moreover, methods of analysis using calibration curve and standard additions are presented. The possible cause of error associated with iron determination in organic samples by flame (F-A.A.S.) and graphite furnace (GF-A.A.S.) atomic absorption spectrometry are discussed. From all of these studies, the use of graphite furnace atomic absorption spectrometry after sample dilution with methyl isobutyl ketone, and the use of the method of standard additions are advised for iron determination.

  15. Infrared absorption on a complex comprising three equivalent hydrogen atoms in ZnO

    NASA Astrophysics Data System (ADS)

    Herklotz, F.; Hupfer, A.; Johansen, K. M.; Svensson, B. G.; Koch, S. G.; Lavrov, E. V.

    2015-10-01

    A hydrogen-related defect in ZnO which causes two broad IR absorption bands at 3303 and 3321 cm-1 is studied by means of infrared absorption spectroscopy and first-principles theory. In deuterated samples, the defect reveals two sharp absorption lines at 2466 and 2488 cm-1 accompanied by weaker sidebands at 2462 and 2480 cm-1. Isotope substitution experiments with varying concentrations of H and D together with polarization-sensitive measurements strongly suggest that these IR absorption lines are due to stretch local vibrational modes of a defect comprising three equivalent hydrogen atoms. The zinc vacancy decorated by three hydrogen atoms, VZnH3 , and ammonia trapped at the zinc vacancy, (NH3)Zn, are discussed as a possible origin for the complex.

  16. Franck-Condon factors perturbed by damped harmonic oscillators: Solvent enhanced X 1Ag ↔ A1B1u absorption and fluorescence spectra of perylene

    NASA Astrophysics Data System (ADS)

    Wang, Chen-Wen; Yang, Ling; Zhu, Chaoyuan; Yu, Jian-Guo; Lin, Sheng-Hsien

    2014-08-01

    Damped harmonic oscillators are utilized to calculate Franck-Condon factors within displaced harmonic oscillator approximation. This is practically done by scaling unperturbed Hessian matrix that represents local modes of force constants for molecule in gaseous phase, and then by diagonalizing perturbed Hessian matrix it results in direct modification of Huang-Rhys factors which represent normal modes of solute molecule perturbed by solvent environment. Scaling parameters are empirically introduced for simulating absorption and fluorescence spectra of an isolated solute molecule in solution. The present method is especially useful for simulating vibronic spectra of polycyclic aromatic hydrocarbon molecules in which hydrogen atom vibrations in solution can be scaled equally, namely the same scaling factor being applied to all hydrogen atoms in polycyclic aromatic hydrocarbons. The present method is demonstrated in simulating solvent enhanced X 1Ag ↔ A1B1u absorption and fluorescence spectra of perylene (medium-sized polycyclic aromatic hydrocarbon) in benzene solution. It is found that one of six active normal modes v10 is actually responsible to the solvent enhancement of spectra observed in experiment. Simulations from all functionals (TD) B3LYP, (TD) B3LYP35, (TD) B3LYP50, and (TD) B3LYP100 draw the same conclusion. Hence, the present method is able to adequately reproduce experimental absorption and fluorescence spectra in both gas and solution phases.

  17. [Determination of mercury in shark liver by cold atom fluorescence spectrometry after microwave dissolution].

    PubMed

    Weng, Di

    2005-12-01

    The conditions for the determination of mercury in shark liver by cold atom fluorescence spectrometry (CAFS) with microwave dissolution were studied. After being dried completely, the method employed 2 mol x L(-1) HNO3-4 mol x L(-1) HCl as an oxidant, and with catalysis by V2O5, the samples were digested in a microwave oven. The mercury in absorption solution was reduced by SnCl2, and then was determined by CAFS at wavelength of 253.7 nm. 10% SnCl2 solution was used as a reductive agent for mercury. The linear range was 0-2.0 ng x mL(-1) mercury (r = 0.999 7). The detection limit was 0.05 ng x mL(-1), the relative standard deviation was 0.86%-2.22%, and the average recovery rate was 96.0%-108.5%. The method was suitable for the determination of mercury in shark liver.

  18. Interactions of hypericin with a model mutagen - Acridine orange analyzed by light absorption and fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Pietrzak, Monika; Szabelski, Mariusz; Kasparek, Adam; Wieczorek, Zbigniew

    2017-02-01

    The present study was designed to estimate the ability of hypericin to interact with a model mutagen - acridine orange. The hetero-association of hypericin and acridine orange was investigated with absorption and fluorescence spectroscopy methods in aqueous solution of DMSO. The data indicate that hypericin forms complexes with acridine orange and that the association constants are relatively high and depend on DMSO concentration. The absorption spectra of the hypericin - acridine orange complexes were examined as well. Owing to its ability to interact with flat aromatic compounds, hypericin may potentially be used as an interceptor molecule.

  19. Fluorescence and absorption spectroscopy of the weakly fluorescent chlorophyll a in cytochrome b6f of Synechocystis PCC6803.

    PubMed Central

    Peterman, E J; Wenk, S O; Pullerits, T; Pâlsson, L O; van Grondelle, R; Dekker, J P; Rögner, M; van Amerongen, H

    1998-01-01

    A spectroscopic characterization of the chlorophyll a (Chl) molecule in the monomeric cytochrome b6f complex (Cytb6f) isolated from the cyanobacterium Synechocystis PCC6803 is presented. The fluorescence lifetime and quantum yield have been determined, and it is shown that Chl in Cytb6f has an excited-state lifetime that is 20 times smaller than that of Chl in methanol. This shortening of the Chl excited state lifetime is not caused by an increased rate of intersystem crossing. Most probably it is due to quenching by a nearby amino acid. It is suggested that this quenching is a mechanism for preventing the formation of Chl triplets, which can lead to the formation of harmful singlet oxygen. Using site-selected fluorescence spectroscopy, detailed information on vibrational frequencies in both the ground and Qy excited states has been obtained. The vibrational frequencies indicate that the Chl molecule has one axial ligand bound to its central magnesium and accepts a hydrogen bond to its 13(1)-keto carbonyl. The results show that the Chl binds to a well-defined pocket of the protein and experiences several close contacts with nearby amino acids. From the site-selected fluorescence spectra, it is further concluded that the electron-phonon coupling is moderately strong. Simulations of both the site-selected fluorescence spectra and the temperature dependence of absorption and fluorescence spectra are presented. These simulations indicate that the Huang-Rhys factor characterizing the electron-phonon coupling strength is between 0.6 and 0.9. The width of the Gaussian inhomogeneous distribution function is 210 +/- 10 cm-1. PMID:9649396

  20. Metal content monitoring in Hypericum perforatum pharmaceutical derivatives by atomic absorption and emission spectrometry.

    PubMed

    Gomez, María R; Soledad, Cerutti; Olsina, Roberto A; Silva, María F; Martínez, Luis D

    2004-02-18

    Metals have been investigated in different plant materials in order to establish their normal concentration range and consider their role in plants as part of human medicinal treatment. Metal monitoring as a pattern recognition method is a promising tool in the characterization and/or standardization of phytomedicines. In the present work measurable amounts of Ca, Cu, K, Li, Mg, Mn, Na, Ni, and Zn were detected in phytopharmaceutical derivatives of Hypericum perforatum by atomic techniques. Atomic methodologies like flame atomic absorption spectrometry (FAAS) and electrothermal atomic absorption spectrometry (ETAAS) allow reliable determination of mineral content in pharmaceutical quality control of medicinal plants. Additionally, capillary electrophoresis (CE) patterns of characteristic components (fingerprints) have been performed for the search of adulterants in phytopharmaceutical products.

  1. Methods for analysis of selected metals in water by atomic absorption

    USGS Publications Warehouse

    Fishman, Marvin J.; Downs, Sanford C.

    1966-01-01

    This manual describes atomic-absorption-spectroscopy methods for determining calcium, copper, lithium, magnesium, manganese, potassium, sodium, strontium and zinc in atmospheric precipitation, fresh waters, and brines. The procedures are intended to be used by water quality laboratories of the Water Resources Division of the U.S. Geological Survey. Detailed procedures, calculations, and methods for the preparation of reagents are given for each element along with data on accuracy, precision, and sensitivity. Other topics discussed briefly are the principle of atomic absorption, instrumentation used, and special analytical techniques.

  2. Atomic absorption spectrophotometric method for determination of polydimethylsiloxane residues in pineapple juice: collaborative study.

    PubMed

    Parker, R D

    1990-01-01

    An atomic absorption spectrophotometric method for determination of polydimethylsiloxane (PDMS) residues in pineapple juice was collaboratively studied by 9 laboratories. PDMS residues are extracted from pineapple juice with 4-methyl-2-pentanone and the extracted silicone is measured by atomic absorption spectrophotometry using a nitrous oxide/acetylene flame. Collaborators analyzed 5 samples including 1 blind duplicate. Reproducibility relative standard deviations (RSDR) were 13.1% at 31 ppm, 6.9% at 18 ppm, 14.8% at 7.9 ppm, and 16.1% at 4.9 ppm PDMS. The method has been approved interim official first action by AOAC.

  3. Determination of cadmium vapor pressure over dichromium cadmium tetraselenide by the atomic absorption method

    SciTech Connect

    Bel'skii, N.K.; Ochertyanova L.I.; Zhegalinka, V.A.

    1986-07-01

    By the atomic absorption method one measures the light absorption by the vapor of the investigated element as a function of the temperature of the evaporating surface. To measure vapor pressure the authors use cadmium selenide of the purity grade, which was recrystallized by sublimitation. The optical density of the vapor over cadmium selenide was determined in the temperature range 820-890 K. Using atomic spectroscopy the vapor pressure of cadmium over cadmium selenide was determined in dichromium cadmium tetraselenide with different amounts of deviation from stoichiometry at 790-880 deg. The results are compared with the literature data.

  4. Solvatochromic Shifts on Absorption and Fluorescence Bands of N,N-Dimethylaniline.

    PubMed

    Fdez Galván, Ignacio; Elena Martín, M; Muñoz-Losa, Aurora; Aguilar, Manuel A

    2009-02-10

    A theoretical study of the absorption and fluorescence UV/vis spectra of N,N-dimethylaniline in different solvents has been performed, using a method combining quantum mechanics, molecular mechanics, and the mean field approximation. The transitions between the three lowest-lying states have been calculated in vacuum as well as in cyclohexane, tetrahydrofuran, and water. The apparent anomalies experimentally found in water (a blue shift in the absorption bands with respect to the trend in other solvents, and an abnormally high red shift for the fluorescence band) are well reproduced and explained in view of the electronic structure of the solute and the solvent distribution around it. Additional calculations were done with a mixture of cyclohexane and tetrahydrofuran as solvent, which displays a nonlinear solvatochromic shift. Results, although not conclusive, are consistent with experiment and provide a possible explanation for the nonlinear behavior in the solvent mixture.

  5. Optical imaging of non-fluorescent nanodiamonds in live cells using transient absorption microscopy

    NASA Astrophysics Data System (ADS)

    Chen, Tao; Lu, Feng; Streets, Aaron M.; Fei, Peng; Quan, Junmin; Huang, Yanyi

    2013-05-01

    We directly observe non-fluorescent nanodiamonds in living cells using transient absorption microscopy. This label-free technology provides a novel modality to study the dynamic behavior of nanodiamonds inside the cells with intrinsic three-dimensional imaging capability. We apply this method to capture the cellular uptake of nanodiamonds under various conditions, confirming the endocytosis mechanism.We directly observe non-fluorescent nanodiamonds in living cells using transient absorption microscopy. This label-free technology provides a novel modality to study the dynamic behavior of nanodiamonds inside the cells with intrinsic three-dimensional imaging capability. We apply this method to capture the cellular uptake of nanodiamonds under various conditions, confirming the endocytosis mechanism. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr00308f

  6. Temporal and spatial temperature distributions in transversely heated graphite tube atomizers and their analytical characteristics for atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Sperling, Michael; Welz, Bernard; Hertzberg, Joachim; Rieck, Christof; Marowsky, Gerd

    1996-07-01

    The important role which temperature plays in atomic absorption spectrometry (AAS) for the formation and detection of atoms in the absorption volume is discussed and the literature is reviewed. Non-homogeneous temperature distribution in the absorption volume is in contradiction to one of the prerequisites for the application of Beer's law used in AAS to convert absorbance into analyte concentration or mass, and is particularly troublesome for an "absolute analysis" envisaged for electrothermal atomic absorption spectrometry (ETAAS). Coherent anti-Stokes Raman scattering (CARS) is used to study the gas-phase temperature distribution in a state-of-the-art transversely heated graphite tube atomizer (THGA). The effect of the internal gas flow on the size of the heated atmosphere is studied by steady-state temperature measurements. Temporally and spatially resolved measurements make it possible to study the temperature field within the atomizer volume in all three dimensions during the rapid heating of the furnace to final temperatures in the range 2173-2673 K. The role of the integrated platform of the THGA on the temperature field is investigated by temperature measurements of the gas phase in the presence and absence of the platform. The platform is identified as the major source of temperature gradients inside the tube volume, which may be as high as 1000 K in the radial direction during rapid heating. These gradients are most pronounced for heating cycles starting at room temperature and gradually decrease with increasing starting temperature. Shortly after the tube wall reaches its final temperature, the gas-phase temperature equilibrates and approaches the wall temperature. Because of the unavoidable contact with the cold environment at the open ends of the tube, minor temperature gradients are observed in the gas phase also in longitudinal direction, which can be further reduced by restricting the openings with end caps. The results obtained for the THGA are

  7. Donor-acceptor substituted phenylethynyltriphenylenes – excited state intramolecular charge transfer, solvatochromic absorption and fluorescence emission

    PubMed Central

    Nandy, Ritesh

    2010-01-01

    Summary Several 2-(phenylethynyl)triphenylene derivatives bearing electron donor and acceptor substituents on the phenyl rings have been synthesized. The absorption and fluorescence emission properties of these molecules have been studied in solvents of different polarity. For a given derivative, solvent polarity had minimal effect on the absorption maxima. However, for a given solvent the absorption maxima red shifted with increasing conjugation of the substituent. The fluorescence emission of these derivatives was very sensitive to solvent polarity. In the presence of strongly electron withdrawing (–CN) and strongly electron donating (–NMe2) substituents large Stokes shifts (up to 130 nm, 7828 cm−1) were observed in DMSO. In the presence of carbonyl substituents (–COMe and –COPh), the largest Stokes shift (140 nm, 8163 cm−1) was observed in ethanol. Linear correlation was observed for the Stokes shifts in a Lippert–Mataga plot. Linear correlation of Stokes shift was also observed with E T(30) scale for protic and aprotic solvents but with different slopes. These results indicate that the fluorescence emission arises from excited state intramolecular charge transfer in these molecules where the triphenylene chromophore acts either as a donor or as an acceptor depending upon the nature of the substituent on the phenyl ring. HOMO–LUMO energy gaps have been estimated from the electrochemical and spectral data for these derivatives. The HOMO and LUMO surfaces were obtained from DFT calculations. PMID:21085512

  8. X-ray absorption and soft x-ray fluorescence analysis of KDP optics

    SciTech Connect

    Nelson, A J; van Buuren, T; Miller, E; Land, T A; Bostedt, C; Franco, N; Whitman, P K; Baisden, P A; Terminello, L J; Callcott, T A

    2000-08-09

    Potassium Dihydrogen Phosphate (KDP) is a non-linear optical material used for laser frequency conversion and optical switches. Unfortunately, when KDP crystals are coated with a porous silica anti-reflection coating [1] and then exposed to ambient humidity, they develop dissolution pits [2,3]. Previous investigations [2] have shown that thermal annealing renders KDP optics less susceptible to pitting suggesting that a modification of surface chemistry has occurred. X-ray absorption and fluorescence were used to characterize changes in the composition and structure of KDP optics as a function of process parameters. KDP native crystals were also analyzed to provide a standard basis for interpretation. Surface sensitive total electron yield and bulk sensitive fluorescence yield from the K 2p, P 2p (L{sub 2,3}-edge) and O 1s (K-edge) absorption edges were measured at each process step. Soft X-ray fluorescence was also used to observe changes associated with spectral differences noted in the absorption measurements. Results indicate that annealing at 160 C dehydrates the surface of KDP resulting in a metaphosphate surface composition with K:P:O = 1:1:3.

  9. Fluorescence upconversion properties of a class of improved pyridinium dyes induced by two-photon absorption

    NASA Astrophysics Data System (ADS)

    Xu, Guibao; Hu, Dawei; Zhao, Xian; Shao, Zongshu; Liu, Huijun; Tian, Yupeng

    2007-06-01

    We report the fluorescence upconversion properties of a class of improved pyridinium toluene- p-sulfonates having donor- π-acceptor (D- π-A) structure under two-photon excitation at 1064 nm. The experimental results show that both the two-photon excited (TPE) fluorescence lifetime and the two-photon pumped (TPP) energy upconversion efficiency were increased with the enhancement of electron-donating capability of the donor in the molecule. It is also indicated that an overlong alkyl group tends to result in a weakened molecular conjugation, leading to a decreased two-photon absorption (TPA) cross section. By choosing the donor, we can obtain a longest fluorescence lifetime of 837 ps, a highest energy upconversion efficiency of ˜6.1%, and a maximum TPA cross-section of 8.74×10 -48 cm 4 s/photon in these dyes.

  10. Transmission and fluorescence X-ray absorption spectroscopy cell/flow reactor for powder samples under vacuum or in reactive atmospheres

    NASA Astrophysics Data System (ADS)

    Hoffman, A. S.; Debefve, L. M.; Bendjeriou-Sedjerari, A.; Ould-Chikh, S.; Bare, Simon R.; Basset, J.-M.; Gates, B. C.

    2016-07-01

    X-ray absorption spectroscopy is an element-specific technique for probing the local atomic-scale environment around an absorber atom. It is widely used to investigate the structures of liquids and solids, being especially valuable for characterization of solid-supported catalysts. Reported cell designs are limited in capabilities—to fluorescence or transmission and to static or flowing atmospheres, or to vacuum. Our goal was to design a robust and widely applicable cell for catalyst characterizations under all these conditions—to allow tracking of changes during genesis and during operation, both under vacuum and in reactive atmospheres. Herein, we report the design of such a cell and a demonstration of its operation both with a sample under dynamic vacuum and in the presence of gases flowing at temperatures up to 300 °C, showing data obtained with both fluorescence and transmission detection. The cell allows more flexibility in catalyst characterization than any reported.

  11. Polarized fluorescence and absorption of macroscopically aligned Light Harvesting Complex II.

    PubMed

    van Amerongen, H; Kwa, S L; van Bolhuis, B M; van Grondelle, R

    1994-08-01

    Polarized absorption and fluorescence measurements have been performed at 77 K on isotropic and anisotropic preparations of trimeric Light Harvesting Complex II (LHC-II) from spinach. The results enable a decomposition of the absorption spectrum into components parallel and perpendicular to the trimeric plane. For the first time, it is shown quantitatively that the strong absorption band around 676 nm is polarized essentially parallel to the plane of the trimer, i.e., the average angle between the corresponding transition dipole moments and this plane is at most 12 degrees. The different absorption bands for LHC-II should not be considered as corresponding to individual pigments but to collective excitations of different pigments. Nevertheless, the average angle between the Qy transition dipole moments of all chlorophyll a pigments in LHC-II and the trimeric plane could be determined and was found to be 17.5 degrees +/- 2.5 degrees. For the chlorophyll b pigments, this angle is significantly larger (close to 35 degrees). At 77 K, most of the fluorescence stems from a weak band above 676 nm and the corresponding transition dipole moments are oriented further out of plane than the dipole moments corresponding to the 676-nm band. The results are shown to be of crucial significance for understanding the relation between the LHC-II structure and its spectroscopy.

  12. Picosecond-TALIF and VUV absorption measurements of absolute atomic nitrogen densities from an RF atmospheric pressure plasma jet with He/O2/N2 gas mixtures

    NASA Astrophysics Data System (ADS)

    West, Andrew; Niemi, Kari; Schröter, Sandra; Bredin, Jerome; Gans, Timo; Wagenaars, Erik

    2015-09-01

    Reactive Oxygen and Nitrogen species (RONS) from RF atmospheric pressure plasma jets (APPJs) are important in biomedical applications as well as industrial plasma processing such as surface modification. Atomic oxygen has been well studied, whereas, despite its importance in the plasma chemistry, atomic nitrogen has been somewhat neglected due to its difficulty of measurement. We present absolute densities of atomic nitrogen in APPJs operating with He/O2/N2 gas mixtures in open air, using picosecond Two-photon Absorption Laser Induced Fluorescence (ps-TALIF) and vacuum ultra-violet (VUV) absorption spectroscopy. In order to apply the TALIF technique in complex, He/O2/N2 mixtures, we needed to directly measure the collisional quenching effects using picosecond pulse widths (32ps). Traditional calculated quenching corrections, used in nanosecond TALIF, are inadequate due to a lack of quenching data for complex mixtures. Absolute values for the densities were found by calibrating against a known density of Krypton. The VUV absorption experiments were conducted on the DESIRS synchrotron beamline using a unique VUV Fourier-transform spectrometer. Atomic nitrogen densities were on the order of 1020 m-3 with good agreement between TALIF and VUV absorption. UK EPSRC grant EP/K018388/1.

  13. Determination of arsenic and selenium in environmental and agricultural samples by hydride generation atomic absorption spectrometry

    SciTech Connect

    Hershey, J.W.; Oostdyk, T.S.; Keliher, P.N.

    1988-11-01

    Agricultural and environmental samples are digested with acid, and arsenic and selenium are determined using hydride generation atomic absorption spectrometry. Interelement interferences are eliminated by high acid concentrations or cation-exchange resins. Agreement with standard reference material is excellent. The technique is also applied to actual samples.

  14. Circuit Board Analysis for Lead by Atomic Absorption Spectroscopy in a Course for Nonscience Majors

    ERIC Educational Resources Information Center

    Weidenhammer, Jeffrey D.

    2007-01-01

    A circuit board analysis of the atomic absorption spectroscopy, which is used to measure lead content in a course for nonscience majors, is being presented. The experiment can also be used to explain the potential environmental hazards of unsafe disposal of various used electronic equipments.

  15. DETERMINING BERYLLIUM IN DRINKING WATER BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY

    EPA Science Inventory

    A direct graphite furnace atomic absorption spectroscopy method for the analysis of beryllium in drinking water has been derived from a method for determining beryllium in urine. Ammonium phosphomolybdate and ascorbic acid were employed as matrix modifiers. The matrix modifiers s...

  16. COMPREHENSIVE ANALYSIS OF BIOLOGICALLY RELEVANT ARSENICALS BY PH-SELECTIVE HYDRIDE GENERATION-ATOMIC ABSORPTION SPECTROMETRY

    EPA Science Inventory


    A method based on pH-selective generation and separation of arsines is commonly used for analysis of inorganic, methylated, and dimethylated trivalent and pentavalent arsenicals by hydride generation-atomic absorption spectrometry (HG-AAS). We have optimized this method to pe...

  17. The Use of an Air-Natural Gas Flame in Atomic Absorption.

    ERIC Educational Resources Information Center

    Melucci, Robert C.

    1983-01-01

    Points out that excellent results are obtained using an air-natural gas flame in atomic absorption experiments rather than using an air-acetylene flame. Good results are obtained for alkali metals, copper, cadmium, and zinc but not for the alkaline earths since they form refractory oxides. (Author/JN)

  18. Determination of sub microgram amounts of selenium in rocks by atomic-absorption spectroscopy.

    PubMed

    Golembeski, T

    1975-06-01

    Atomic-absorption spectroscopy was used to determine trace amounts of selenium accurately in U.S. Geological Survey standard rocks, GSP-1, W-1 and BCR-1. The results obtained were compared with those obtained by neutron-activation analysis and excellent agreement was found; in addition, the selenium:sulphur ratio was calculated and agreed with results obtained by other workers.

  19. Point defect absorption by grain boundaries in α -iron by atomic density function modeling

    NASA Astrophysics Data System (ADS)

    Kapikranian, O.; Zapolsky, H.; Patte, R.; Pareige, C.; Radiguet, B.; Pareige, P.

    2015-12-01

    Using the atomic density function theory (ADFT), we examine the point defect absorption at [110] symmetrical tilt grain boundaries in body-centered cubic iron. It is found that the sink strength strongly depends on misorientation angle. We also show that the ADFT is able to reproduce reasonably well the elastic properties and the point defect formation volume in α -iron.

  20. Containerless high temperature property measurements by atomic fluorescence

    NASA Technical Reports Server (NTRS)

    1983-01-01

    The use of laser induced fluorescence (LIF) techniques for containerless study of high temperature processes and material properties is studied. Gas jet and electromagnetic levitation and electromagnetic and laser heating techniques are used with LIF in Earth-based containerless high temperature experiments. The work to date includes development of an apparatus and its use in studies of chemical reactions on Al2O3, molybdenum, and tungsten specimens, novel methods for noncontact specimen temperature measurement, and levitation jet properties. Brief summaries of these studies are given. The apparatus is described and detailed results for the current reporting period are presented.

  1. Optical pumping effect in absorption imaging of F =1 atomic gases

    NASA Astrophysics Data System (ADS)

    Kim, Sooshin; Seo, Sang Won; Noh, Heung-Ryoul; Shin, Y.

    2016-08-01

    We report our study of the optical pumping effect in absorption imaging of 23Na atoms in the F =1 hyperfine spin states. Solving a set of rate equations for the spin populations in the presence of a probe beam, we obtain an analytic expression for the optical signal of the F =1 absorption imaging. Furthermore, we verify the result by measuring the absorption spectra of 23Na Bose-Einstein condensates prepared in various spin states with different probe-beam pulse durations. The analytic result can be used in the quantitative analysis of F =1 spinor condensate imaging and readily applied to other alkali-metal atoms with I =3 /2 nuclear spin such as 87Rb.

  2. Enhanced Reverse Saturable Absorption and Optical Limiting in Heavy-Atom Substituted Phthalocyanines

    NASA Technical Reports Server (NTRS)

    Perry, J. W.; Mansour, K.; Marder, S. R.; Alvarez, D., Jr.; Perry, K. J.; Choong, I.

    1994-01-01

    The reverse saturable absorption and optical limiting response of metal phthalocyaninies can be enhanced by using the heavy-atom effect. Phthalocyanines containing heavy metal atoms, such as In, Sn, and Pb show nearly a factor of two enhancement in the ratio of effective excited-state to ground-state absorption cross sections compared to those containing lighter atoms, such as Al and Si. In an f/8 optical geometry, homogeneous solutions of heavy metal phthalocyanines, at 30% linear transmission, limit 8-ns, 532-nm laser pulses to less than or equal to 3 (micro)J (the energy for 50% probability of eye damage) for incident pulses up to 800 (micro)J.

  3. Properties of far-field fluorescence from an ensemble of interacting Sr atoms

    NASA Astrophysics Data System (ADS)

    Yu, Deshui

    2016-03-01

    We systematically investigate the far-zone fluorescence from a number of laser-driven two-level atoms with the cooperative effects stemming from the virtual exchange of photons between identical atoms. Due to the large interaction-induced energy level shifts, i.e. the collective Lamb shifts, both atomic excitation and photon emission do not maximize at the resonant light-atom coupling. In addition, the long-range dissipative interactions among atoms lead to the disproportion between the atomic excitation and the photon emission. Moreover, we discuss the temporal properties of the far-field fluorescence light from the atomic ensemble. The first-order correlation function indicates a damped light-atom dynamics combined with a strong background of the elastic photon scattering. The second-order correlation function illustrates that in the weak-excitation limit the scattered light exhibits the nonclassical photon antibunching behavior, while the bunched photons arrive at the photodetector in the saturated-excitation limit.

  4. Absorption into fluorescence. A method to sense biologically relevant gas molecules

    NASA Astrophysics Data System (ADS)

    Strianese, Maria; Varriale, Antonio; Staiano, Maria; Pellecchia, Claudio; D'Auria, Sabato

    2011-01-01

    In this work we present an innovative optical sensing methodology based on the use of biomolecules as molecular gating nano-systems. Here, as an example, we report on the detection ofanalytes related to climate change. In particular, we focused our attention on the detection ofnitric oxide (NO) and oxygen (O2). Our methodology builds on the possibility of modulating the excitation intensity of a fluorescent probe used as a transducer and a sensor molecule whose absorption is strongly affected by the binding of an analyte of interest used as a filter. The two simple conditions that have to be fulfilled for the method to work are: (a) the absorption spectrum of the sensor placed inside the cuvette, and acting as the recognition element for the analyte of interest, should strongly change upon the binding of the analyte and (b) the fluorescence dye transducer should exhibit an excitation band which overlaps with one or more absorption bands of the sensor. The absorption band of the sensor affected by the binding of the specific analyte should overlap with the excitation band of the transducer. The high sensitivity of fluorescence detection combined with the use of proteins as highly selective sensors makes this method a powerful basis for the development of a new generation of analytical assays. Proof-of-principle results showing that cytochrome c peroxidase (CcP) for NO detection and myoglobin (Mb) for O2 detection can be successfully used by exploiting our new methodology are reported. The proposed technology can be easily expanded to the determination of different target analytes.

  5. Absorption into fluorescence. A method to sense biologically relevant gas molecules.

    PubMed

    Strianese, Maria; Varriale, Antonio; Staiano, Maria; Pellecchia, Claudio; D'Auria, Sabato

    2011-01-01

    In this work we present an innovative optical sensing methodology based on the use of biomolecules as molecular gating nano-systems. Here, as an example, we report on the detection of analytes related to climate change. In particular, we focused our attention on the detection of nitric oxide (NO) and oxygen (O2). Our methodology builds on the possibility of modulating the excitation intensity of a fluorescent probe used as a transducer and a sensor molecule whose absorption is strongly affected by the binding of an analyte of interest used as a filter. The two simple conditions that have to be fulfilled for the method to work are: (a) the absorption spectrum of the sensor placed inside the cuvette, and acting as the recognition element for the analyte of interest, should strongly change upon the binding of the analyte and (b) the fluorescence dye transducer should exhibit an excitation band which overlaps with one or more absorption bands of the sensor. The absorption band of the sensor affected by the binding of the specific analyte should overlap with the excitation band of the transducer. The high sensitivity of fluorescence detection combined with the use of proteins as highly selective sensors makes this method a powerful basis for the development of a new generation of analytical assays. Proof-of-principle results showing that cytochrome c peroxidase (CcP) for NO detection and myoglobin (Mb) for O2 detection can be successfully used by exploiting our new methodology are reported. The proposed technology can be easily expanded to the determination of different target analytes.

  6. Absorption spectra and spectral-kinetic characteristics of the fluorescence of Sanguinarine in complexes with polyelectrolytes and DNA

    NASA Astrophysics Data System (ADS)

    Motevich, I. G.; Strekal, N. D.; Nowicky, J. W.; Maskevich, S. A.

    2010-07-01

    The absorption spectra and stationary and time resolved fluorescence spectra of the isoquinoline alkaloid sanguinarine are studied in aqueous media and during interactions with synthetic polyelectrolytes (polystyrene sulfonate and polyallylamine) and a natural polyelectrolyte (DNA).

  7. Continuous flow hydride generation-atomic fluorescence spectrometric determination and speciation of arsenic in wine

    NASA Astrophysics Data System (ADS)

    Karadjova, Irina B.; Lampugnani, Leonardo; Onor, Massimo; D'Ulivo, Alessandro; Tsalev, Dimiter L.

    2005-07-01

    Methods for the atomic fluorescence spectrometric (AFS) determination of total arsenic and arsenic species in wines based on continuous flow hydride generation (HG) with atomization in miniature diffusion flame (MDF) are described. For hydride-forming arsenic, L-cysteine is used as reagent for pre-reduction and complexation of arsenite, arsenate, monomethylarsonate and dimethylarsinate. Concentrations of hydrochloric acid and tetrahydroborate are optimized in order to minimize interference by ethanol. Procedure permits determination of the sum of these four species in 5-10-fold diluted samples with limit of detection (LOD) 0.3 and 0.6 μg l - 1 As in white and red wines, respectively, with precision between 2% and 8% RSD at As levels within 0.5-10 μg l - 1 . Selective arsine generation from different reaction media is used for non-chromatographic determination of arsenic species in wines: citrate buffer at pH 5.1 for As(III); 0.2 mol l - 1 acetic acid for arsenite + dimethylarsinate (DMA); 8 mol l - 1 HCl for total inorganic arsenic [As(III) + As(V)]; and monomethylarsonate (MMA) calculated by difference. Calibration with aqueous and ethanol-matched standard solutions of As(III) is used for 10- and 5-fold diluted samples, respectively. The LODs are 0.4 μg l - 1 for As(III) and 0.3 μg l - 1 for the other three As species and precision is within 4-8% RSDs. Arsenic species in wine were also determined by coupling of ion chromatographic separation on an anion exchange column and HG-flame AFS detection. Methods were validated by means of recovery studies and comparative analyses by HG-AFS and electrothermal atomic absorption spectrometry after microwave digestion. The LODs were 0.12, 0.27, 0.15 and 0.13 μg l - 1 (as As) and RSDs were 2-6%, 5-9%, 3-7% and 2-5% for As(III), As(V), MMA and DMA arsenic species, respectively. Bottled red and white wines from Bulgaria, Republic of Macedonia and Italy were analyzed by non-chromatographic and chromatographic procedures and

  8. Absorption and fluorescence of alexandrite and of titanium in sapphire and glass

    NASA Technical Reports Server (NTRS)

    Byvik, C. E.; Hess, R. V.; Buoncristiani, A. M.

    1985-01-01

    The fluorescence and absorption data for titanium in crystalline sapphire and titanium doped into two silicate and one phosphate glass structures are analyzed. It is observed that the Ti-doped silicate glass sample exhibits no absorption related to the Ti(III) ion, the Ti-doped phosphate glass is deep blue, the absorption line width of the glass samples are a factor of two larger than that of sapphire, and the absorption peak for the Ti in the glass shifted about 100 nm to the red from the Ti:sapphire absorption peak. This shift reveals that the Ti(III) ion is sensitive to the crystalline environment and not to the glass environment. The photoluminescence spectra for Ti-doped sapphire and alexandrite are compared. It is detected that the Ti:sapphire exhibits a broader spectrum than that for alexandrite with a peak at 750 nm. The three zero phonon transitions of Ti:Al2O3 at liquid nitrogen temperatures are studied.

  9. Determination of Calcium in Cereal with Flame Atomic Absorption Spectroscopy: An Experiment for a Quantitative Methods of Analysis Course

    ERIC Educational Resources Information Center

    Bazzi, Ali; Kreuz, Bette; Fischer, Jeffrey

    2004-01-01

    An experiment for determination of calcium in cereal using two-increment standard addition method in conjunction with flame atomic absorption spectroscopy (FAAS) is demonstrated. The experiment is intended to introduce students to the principles of atomic absorption spectroscopy giving them hands on experience using quantitative methods of…

  10. Laser-Excited Atomic Fluorescence and Ionization in a Graphite Furnace for the Determination of Metals and Nonmetals

    NASA Astrophysics Data System (ADS)

    Butcher, David James

    1990-01-01

    Here is reported novel instrumentation for atomic spectrometry that combined the use of a pulsed laser system as the light source and an electrothermal atomizer as the atom cell. The main goal of the research was to develop instrumentation that was more sensitive for elemental analysis than commercially available instruments and could be used to determine elements in real sample matrices. Laser excited atomic fluorescence spectrometry (LEAFS) in an electrothermal atomizer (ETA) was compared to ETA atomic absorption spectrometry (AAS) for the determination of thallium, manganese, and lead in food and agricultural standard reference materials (SRMs). Compared to ETA AAS, ETA LEAFS has a longer linear dynamic range (LDR) (5-7 orders of magnitude compared to 2-3 orders of magnitude) and higher sensitivity (10 ^{-16} to 10^{ -14} g as compared to 10^{ -13} to 10^{-11} g). Consequently, ETA LEAFS allows elemental analysis to be done over a wider range of concentrations with less dilution steps. Thallium was accurately determined in biological samples by ETA LEAFS at amounts five to one hundred times below the ETA AAS detection limit. ETA AAS and ETA LEAFS were compared for the determination of lead and manganese, and in general, the accuracies and precisions of ETA AAS were the same, with typical precisions between 3% and 6%. Fluorine was determined using laser excited molecular fluorescence spectrometry (LEMOFS) in an ETA. Molecular fluorescence from magnesium fluoride was collected, and the detection limit of 0.3 pg fluorine was two to six orders of magnitude more sensitive than other methods commonly used for the determination of fluorine. Significant interferences from ions were observed, but the sensitivity was high enough that fluorine could be determined in freeze dried urine SRMs by diluting the samples by a factor of one hundred to remove the interferences. Laser enhanced ionization (LEI) in an ETA was used for the determination of metals. For thallium, indium

  11. Determination of cadmium and lead in urine by derivative flame atomic absorption spectrometry using the atom trapping technique

    NASA Astrophysics Data System (ADS)

    Han-wen, Sun; De-qiang, Zhang; Li-li, Yang; Jian-min, Sun

    1997-06-01

    A method is described for the determinations of cadmium and lead in urine by derivative flame atomic absorption spectrometry with a modified water-cooled stainless steel atom trapping tube. The effects of the trap position, the flame conditions, the coolant flow rates, and the collection time were studied. With a 1 min collection time, the characteristic concentrations (derivative absorbance of 0.0044) for cadmium and lead were 0.028 and 1.4 μg L -1, the detection limits (3σ) were 0.02 and 0.27 μg L -1, respectively. The detection limits and sensitivities of the proposed method were 2 and 3 orders of magnitude higher for 1-3 min collection time than those of conventional flame atomic absorption spectrometry for cadmium and lead, respectively. Urine samples from a small population of normal individuals have been analyzed for cadmium and lead by the proposed method. Satisfactory recoveries of 91-110% and 91-106%, for Cd and Pb were obtained with these urine samples.

  12. Observation of DNA Molecules Using Fluorescence Microscopy and Atomic Force Microscopy

    ERIC Educational Resources Information Center

    Ito, Takashi

    2008-01-01

    This article describes experiments for an undergraduate instrumental analysis laboratory that aim to observe individual double-stranded DNA (dsDNA) molecules using fluorescence microscopy and atomic force microscopy (AFM). dsDNA molecules are observed under several different conditions to discuss their chemical and physical properties. In…

  13. Tunable Diode Laser Atomic Absorption Spectroscopy for Detection of Potassium under Optically Thick Conditions.

    PubMed

    Qu, Zhechao; Steinvall, Erik; Ghorbani, Ramin; Schmidt, Florian M

    2016-04-05

    Potassium (K) is an important element related to ash and fine-particle formation in biomass combustion processes. In situ measurements of gaseous atomic potassium, K(g), using robust optical absorption techniques can provide valuable insight into the K chemistry. However, for typical parts per billion K(g) concentrations in biomass flames and reactor gases, the product of atomic line strength and absorption path length can give rise to such high absorbance that the sample becomes opaque around the transition line center. We present a tunable diode laser atomic absorption spectroscopy (TDLAAS) methodology that enables accurate, calibration-free species quantification even under optically thick conditions, given that Beer-Lambert's law is valid. Analyte concentration and collisional line shape broadening are simultaneously determined by a least-squares fit of simulated to measured absorption profiles. Method validation measurements of K(g) concentrations in saturated potassium hydroxide vapor in the temperature range 950-1200 K showed excellent agreement with equilibrium calculations, and a dynamic range from 40 pptv cm to 40 ppmv cm. The applicability of the compact TDLAAS sensor is demonstrated by real-time detection of K(g) concentrations close to biomass pellets during atmospheric combustion in a laboratory reactor.

  14. Electrothermal atomic-absorption determination of silver in zinc and cadmium selenides

    SciTech Connect

    Khozhainov, Yu.M.; Dolova, N.K.

    1987-10-01

    An atomic-absorption signal is dependent on the chemical forms of the test element and matrix in the solution as well as on the processes during electrothermal atomization. The authors have examined the absorption due to silver with a Saturn-2 spectrophotometer with such atomization; the authors used the 328.1 nm line (i = 10 mA, slit width 0.15, time-constant 0.6 sec). The presence of cadmium and zinc was monitored from the 326.1 and 213.8 nm lines respectively. The measurements were made in argon. The internal gas flow was turned off during the atomization. The graphite was used until there were sharp changes in the silver absorption due to change in the structure of the graphite and occurrence of the memory effect. The results from over 100 specimens of cadmium selenide films analyzed for silver showed that the results were in full agreement with the conditions for silver activation (time, temperature, and activator mass).

  15. Containerless high temperature property measurements by atomic fluorescence

    NASA Technical Reports Server (NTRS)

    Nordine, Paul C.; Shiffman, Robert A.

    1987-01-01

    Containerless high temperature processing and material property measurements are discussed. Researchers developed methods for non-contact suspension, heating, and property measurement for materials at temperatures up to 3,680K, the melting point of tungsten. New, scientifically interesting results were obtained in Earth-based research. These results and the demonstration of new methods and techniques form a basis for further advances under the low gravity environment of space where containerless conditions are more easily achieved. Containerless high temperature material property investigations that have been completed in this and our earlier projects include measurements of fluorine LaB sub 6 reaction kinetics at 1,000 to 1,500K; optical property measurements on sapphire (Al2O3) at temperatures up to the melting point (2,327K); and vapor pressure measurements for LaB sub 6 at 2,000 to 2,500K, for molybdenum up to 2,890K and for tungsten up to 3,680K. Gas jet levitation which is applicable to any solid material, and electromagnetic levitation of electrical conductors were used to suspend the materials of interest. Non-contact heating and property measurements were achieved by optical techniques, i.e., laser heating, laser induced fluorescence measurements of vapor concentrations, and optical pyrometry for specimen temperatures.

  16. Do fluorescence and transient absorption probe the same intramolecular charge transfer state of 4-(dimethylamino)benzonitrile?

    SciTech Connect

    Gustavsson, Thomas; Fujiwara, Takashige; Lim, Edward C.

    2009-07-21

    We present here the results of time-resolved absorption and emission experiments for 4-(dimethylamino)benzonitrile in solution, which suggest that the fluorescent intramolecular charge transfer (ICT) state may differ from the twisted ICT (TICT) state observed in transient absorption.

  17. Self-corrected sensors based on atomic absorption spectroscopy for atom flux measurements in molecular beam epitaxy

    SciTech Connect

    Du, Y. E-mail: scott.chambers@pnnl.gov; Liyu, A. V.; Droubay, T. C.; Chambers, S. A. E-mail: scott.chambers@pnnl.gov; Li, G.

    2014-04-21

    A high sensitivity atom flux sensor based on atomic absorption spectroscopy has been designed and implemented to control electron beam evaporators and effusion cells in a molecular beam epitaxy system. Using a high-resolution spectrometer and a two-dimensional charge coupled device detector in a double-beam configuration, we employ either a non-resonant line or a resonant line with low cross section from the same hollow cathode lamp as the reference for nearly perfect background correction and baseline drift removal. This setup also significantly shortens the warm-up time needed compared to other sensor technologies and drastically reduces the noise coming from the surrounding environment. In addition, the high-resolution spectrometer allows the most sensitive resonant line to be isolated and used to provide excellent signal-to-noise ratio.

  18. Self-corrected sensors based on atomic absorption spectroscopy for atom flux measurements in molecular beam epitaxy

    NASA Astrophysics Data System (ADS)

    Du, Y.; Droubay, T. C.; Liyu, A. V.; Li, G.; Chambers, S. A.

    2014-04-01

    A high sensitivity atom flux sensor based on atomic absorption spectroscopy has been designed and implemented to control electron beam evaporators and effusion cells in a molecular beam epitaxy system. Using a high-resolution spectrometer and a two-dimensional charge coupled device detector in a double-beam configuration, we employ either a non-resonant line or a resonant line with low cross section from the same hollow cathode lamp as the reference for nearly perfect background correction and baseline drift removal. This setup also significantly shortens the warm-up time needed compared to other sensor technologies and drastically reduces the noise coming from the surrounding environment. In addition, the high-resolution spectrometer allows the most sensitive resonant line to be isolated and used to provide excellent signal-to-noise ratio.

  19. Truncated Newton's optimization scheme for absorption and fluorescence optical tomography: Part I theory and formulation.

    PubMed

    Roy, R; Sevick-Muraca, E

    1999-05-10

    The development of non-invasive, biomedical optical imaging from time-dependent measurements of near-infrared (NIR) light propagation in tissues depends upon two crucial advances: (i) the instrumental tools to enable photon "time-of-flight" measurement within rapid and clinically realistic times, and (ii) the computational tools enabling the reconstruction of interior tissue optical property maps from exterior measurements of photon "time-of-flight" or photon migration. In this contribution, the image reconstruction algorithm is formulated as an optimization problem in which an interior map of tissue optical properties of absorption and fluorescence lifetime is reconstructed from synthetically generated exterior measurements of frequency-domain photon migration (FDPM). The inverse solution is accomplished using a truncated Newtons method with trust region to match synthetic fluorescence FDPM measurements with that predicted by the finite element prediction. The computational overhead and error associated with computing the gradient numerically is minimized upon using modified techniques of reverse automatic differentiation.

  20. Observation of upconversion fluorescence and stimulated emission based on three-photon absorption

    NASA Astrophysics Data System (ADS)

    Yang, Q.; Lin, S.; Xu, L.; Yang, F.; Yang, Y.; Pan, L.; Sun, C.; Li, Y.; Sun, G.; Jiang, Z.

    2005-06-01

    The observations of three-photon-induced frequency-upconversion fluorescence and the highly directional stimulated visible emission in two dyes, 4-[p-(dicyanoethylamino) styryl]-N-methylpyridinium iodide (abbreviated as CEASP) and the complex of CEASP and Ce(NO3) (abbreviated as CEASP-Ce), are reported. The photographs of the forward amplified spontaneous emissions spots, pumped by an optical parametric oscillator idler with a pulse width of 8 ns and a wavelength of 1.3 μ m, are shown. The upconversion fluorescence produced both in dimethyl formamide solution and 2-hydroxyethyl methacrylate (HEMA) polymer spans from green to red, with a cubic dependence on the pump light intensity. The experimental results imply that the existence of the lanthanide ion Ce3 + sensitizes the nonlinear absorption and emission.

  1. Observation of the fluorescence spectrum for a driven cascade model system in atomic beam.

    PubMed

    Tian, Si-Cong; Wang, Chun-Liang; Tong, Cun-Zhu; Wang, Li-Jun; Wang, Hai-Hua; Yang, Xiu-Bin; Kang, Zhi-Hui; Gao, Jin-Yue

    2012-10-08

    We experimentally study the resonance fluorescence from an excited two-level atom when the atomic upper level is coupled by a nonresonant field to a higher-lying state in a rubidium atomic beam. The heights, widths and positions of the fluorescence peaks can be controlled by modifying the detuning of the auxiliary field. We explain the observed spectrum with the transition properties of the dressed states generated by the coupling of the two laser fields. We also attribute the line narrowing to the effects of Spontaneously Generated Coherence between the close-lying levels in the dressed state picture generated by the auxiliary field. And the corresponding spectrum can be viewed as the evidence of Spontaneously Generated Coherence. The experimental results agree well with calculations based on the density-matrix equations.

  2. Electrothermal atomization atomic absorption spectrometry for the determination of lead in urine: results of an interlaboratory study

    NASA Astrophysics Data System (ADS)

    Parsons, Patrick J.; Slavin, Walter

    1999-05-01

    Results of an interlaboratory study are reported for the determination of lead in urine. Two levels of a lyophilized material containing biologically-bound lead were prepared using pooled urine obtained from lead-poisoned children undergoing the CaNa 2EDTA mobilization test. The materials were circulated to a group of reference laboratories that participate in the `New York State Proficiency Testing Program for Blood Lead'. Results of the initial round-robin gave all-method consensus target values of 145±22 μg/l (S.D.) for lot 17 and 449±43 μg/l (S.D.) for lot 20. The interlaboratory exercise was repeated some 5 years later and consensus target values were re-calculated using the grand mean (excluding outliers) of results reported by laboratories using electrothermal atomization atomic absorption spectrometry (ETAAS). The re-calculated target values were 139±10 μg/l (S.D.) and 433±12 μg/l (S.D.). The urine reference materials were also analyzed for lead by several laboratories using other instrumental techniques including isotope dilution (ID), inductively coupled plasma (ICP) mass spectrometry (MS), flame atomic absorption with extraction, ICP-atomic emission spectrometry, ID-gas chromatography MS and flow injection-hydride generation AAS, thus providing a rich source of analytical data with which to characterize them. The materials were also used in a long-term validation study of an ETAAS method developed originally for blood lead determinations that has since been used unmodified for the determination of lead in urine also. Recently, urine lead method performance has been tracked in a proficiency testing program specifically for this analysis. In addition, a number of commercial control materials have been analyzed and evaluated.

  3. Determination of zinc in serum, blood, and ultrafiltrate fluid from patients on hemofiltration by graphite furnace/atomic absorption spectroscopy or flow injection analysis/atomic absorption spectroscopy.

    PubMed

    de Blas, O J; Rodriguez, R S; Mendez, J H; Tomero, J A; Gomez, B de L; Gonzalez, S V

    1994-01-01

    Two methods were optimized for the determination of zinc in samples of blood, serum, and ultrafiltrate fluid from patients with chronic renal impairment undergoing hemofiltration. In the first procedure, after acid digestion of the samples, Zn in blood and serum is determined by a system coupled to flow injection analysis and atomic absorption spectroscopy. The method is rapid, automated, simple, needs small amounts of sample, and has acceptable analytical characteristics. The analytical characteristics obtained were as follows: determination range of method, 0.05-2.0 ppm of Zn; precision as coefficient of variation (CV), 5.3%; recovery, 95-105%; and detection limit (DL), 0.02 ppm. The second method is optimized for ultrafiltrate fluid because the sensitivity of the first procedure is not suitable for the levels of Zn (ppb or ng/mL) in these samples. The technique chosen was atomic absorption spectroscopy with electrothermal atomization in a graphite furnace. The analytical characteristics obtained were as follows: determination range of method, 0.3-2.0 ppb Zn; CV, 5.7%; recovery, 93-107%; and DL, 0.12 ppb. The methods were used to determine zinc in samples of blood, serum, and ultrafiltrate fluid from 5 patients with chronic renal impairment undergoing hemofiltration to discover whether there were significant differences in the zinc contents of blood, serum, and ultrafiltrate fluid after the hemofiltration process. An analysis of variance of the experimental data obtained from a randomly selected group of 5 patients showed that zinc concentrations in the ultrafiltrate fluid, venous blood, and venous serum do not vary during hemofiltration (p < 0.05), whereas in arterial blood and serum, the time factor has a significant effect.

  4. Solid sampling determination of magnesium in lithium niobate crystals by graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Dravecz, Gabriella; Laczai, Nikoletta; Hajdara, Ivett; Bencs, László

    2016-12-01

    The vaporization/atomization processes of Mg in high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS-GFAAS) were investigated by evaporating solid (powder) samples of lithium niobate (LiNbO3) optical single crystals doped with various amounts of Mg in a transversally heated graphite atomizer (THGA). Optimal analytical conditions were attained by using the Mg I 215.4353 nm secondary spectral line. An optimal pyrolysis temperature of 1500 °C was found for Mg, while the compromise atomization temperature in THGAs (2400 °C) was applied for analyte vaporization. The calibration was performed against solid (powered) lithium niobate crystal standards. The standards were prepared with exactly known Mg content via solid state fusion of the oxide components of the matrix and analyte. The correlation coefficient (R value) of the linear calibration was not worse than 0.9992. The calibration curves were linear in the dopant concentration range of interest (0.74-7.25 mg/g Mg), when dosing 3-10 mg of the powder samples into the graphite sample insertion boats. The Mg content of the studied 19 samples was in the range of 1.69-4.13 mg/g. The precision of the method was better than 6.3%. The accuracy of the results was verified by means of flame atomic absorption spectrometry with solution sample introduction after digestion of several crystal samples.

  5. Comparison of two absorption imaging methods to detect cold atoms in magnetic trap

    NASA Astrophysics Data System (ADS)

    Wang, Yan; Hu, Zhao-Hui; Qi, Lu

    2015-02-01

    Two methods of absorption imaging to detect cold atoms in a magnetic trap are implemented for a high-precision cold atom interferometer. In the first method, a probe laser which is in resonance with a cycle transition frequency is used to evaluate the quantity and distribution of the atom sample. In the second method, the probe laser is tuned to an open transition frequency, which stimulates a few and constant number of photons per atom. This method has a shorter interaction time and results in absorption images which are not affected by the magnetic field and the light field. We make a comparison of performance between these two imaging methods in the sense of parameters such as pulse duration, light intensity, and magnetic field strength. The experimental results show that the second method is more reliable when detecting the quantity and density profiles of the atoms. These results fit well to the theoretical analysis. Project supported by the National Natural Science Foundation of China (Grant Nos. 61227902 and 61121003) and the National Defense Basic Scientific Research Program of China (Grant No. B2120132005).

  6. Spatial discrimination against background with different optical systems for collection of fluorescence in laser-excited atomic fluorescence spectrometry with a graphite tube electrothermal atomizer.

    PubMed

    Yuzefovsky, A I; Lonardo, R F; Michel, R G

    1995-07-01

    A single 90 degrees off-axis ellipsoidal mirror fragment was used in a dispersive detection system for electrothermal atomization laser-excited atomic fluorescence spectrometry. The performance of the new optical arrangement was compared with those of optical arrangements that employed a plane mirror in combination with biconvex or plano-convex lenses. All the optical arrangements collected fluorescence in a scheme called front surface illustration. BEAM-4, an optical ray tracing program, was used for calculations of spatial ray distributions and optical collection efficiency for the various optical configurations. Experimentally, the best collection efficiency was obtained by use of the ellipsoidal mirror, in qualitative agreement with simulations done by use of the BEAM-4 software. The best detection limit for cobalt with the new optical arrangement was 20 fg, which was a factor of 5 better than that obtained with conventional optical arrangements with otherwise the same instrumentation. The signal-to-background ratio and the fluorescence collection efficiency were also studied as a function of position of the optical components for the various optical arrangements. For both cobalt and phosphorus, the signal-to-background ratio with the new optical arrangement remained stable within 10-20% during +/- 8 mm shifts in the position of the detection system from the focal plane of the optics. Overall, the new optical arrangement offered high collection efficiency, excellent sensitivity, and facile optical alignment due to efficient spatial separation between the fluorescence signal and the background radiation. The advantages of the new optical arrangement were particularly important during measurements in the presence of high levels of blackbody radiation.

  7. Tunable Diode Laser Absorption Spectroscopy of Metastable Atoms in Dusty Plasmas

    SciTech Connect

    Hoang Tung Do; Hippler, Rainer

    2008-09-07

    Spatial density profile of neon metastable produced in dusty plasma was investigated by means of tunable diode laser absorption spectroscopy. The line averaged measured density drops about 30% with the presence of dust particles. The observations provide evidence for a significant interaction between atoms and powder particles which are important for energy transfer from plasma to particles. The power per unit area absorbed by dust particles due to the collision of metastable atoms with dust particle surface is about some tens of mW/m{sup 2}.

  8. Dual structure of saturated absorption resonance at an open atomic transition

    NASA Astrophysics Data System (ADS)

    Vasil'ev, V. V.; Velichanskii, V. L.; Zibrov, S. A.; Sivak, A. V.; Brazhnikov, D. V.; Taichenachev, A. V.; Yudin, V. I.

    2011-05-01

    Experiments on open transitions of the D 1 line of alkali metals (Cs and Rb isotopes) reveal the dual structure of saturated absorption resonance in the signal of a high-intensity optical wave in the presence of a low-intensity counterpropagating wave. Theoretical analysis shows that the observed shape of the resonance is associated with the openness of the atomic transition as well as with the Doppler effect for atoms in a gas. The results are of general physical significance for nonlinear spectroscopy and can also find application in metrology (frequency and time standards on open transitions).

  9. Dual structure of saturated absorption resonance at an open atomic transition

    SciTech Connect

    Vasil'ev, V. V. Velichanskii, V. L. Zibrov, S. A.; Sivak, A. V.; Brazhnikov, D. V. Taichenachev, A. V. Yudin, V. I.

    2011-05-15

    Experiments on open transitions of the D{sub 1} line of alkali metals (Cs and Rb isotopes) reveal the dual structure of saturated absorption resonance in the signal of a high-intensity optical wave in the presence of a low-intensity counterpropagating wave. Theoretical analysis shows that the observed shape of the resonance is associated with the openness of the atomic transition as well as with the Doppler effect for atoms in a gas. The results are of general physical significance for nonlinear spectroscopy and can also find application in metrology (frequency and time standards on open transitions).

  10. CASCADE CALCULATION OF EXOTIC HELIUM ATOMS -- s-orbit vs. p-orbit absorption rates

    NASA Astrophysics Data System (ADS)

    Koike, T.; Akaishi, Y.

    2000-09-01

    We construct a new model for the Stark-mixing process of exotic helium atoms using the impact-parameter method, and compared it with a phenomenological one used so far (sliding transition model). It turns out that the sliding transition model is justified only for low-n states and largely overestimates the Stark-mixing transition rate at high-n states. As a result of the atomic-cascade calculation, the s-(p-)orbit absorption rates in our new model are considerably smaller (larger) than those in the phenomenological one, although both our new model and old one well reproduce the experimental x-ray yields.

  11. [Determination of trace Rh in organic residue by flame atomic absorption spectrophotometry].

    PubMed

    Han, Mei; Cheng, Fang; Gu, Shi-fang; Cui, Li-jun; Xiao, Guang; Xu, Song-yun

    2003-02-01

    The catalytic organic residue contained Rh was digested with HNO3 at 130 degrees C for 12 h. Trace noble metal Rh in catalytic organic residue was determined by flame atomic absorption spectrophotometry. Rh was atomized by air-acetylene flame at lamp Current of 7 mA. The methods of sample pretreatment for Rh in residue were compared in this paper. The recovery rates of this method were 95.3%-105.5% and the relative standard derivation was 0.9%. The method was applied to the analysis of some practical samples and the results obtained were satisfactory.

  12. Three-photon-absorption resonance for all-optical atomic clocks

    SciTech Connect

    Zibrov, Sergei; Novikova, Irina; Phillips, David F.; Taichenachev, Aleksei V.; Yudin, Valeriy I.; Walsworth, Ronald L.; Zibrov, Alexander S.

    2005-07-15

    We report an experimental study of an all-optical three-photon-absorption resonance (known as an 'N resonance') and discuss its potential application as an alternative to atomic clocks based on coherent population trapping. We present measurements of the N-resonance contrast, width and light shift for the D{sub 1} line of {sup 87}Rb with varying buffer gases, and find good agreement with an analytical model of this resonance. The results suggest that N resonances are promising for atomic clock applications.

  13. An improved electrothermal atomic absorption spectroscopy method for the determination of lithium in molybdenum oxide using slurry sampling and a tungsten atomizer

    NASA Astrophysics Data System (ADS)

    Dočekal, Bohumil; Krivan, Viliam

    1993-11-01

    A transversely heated tungsten-tube atomizer, WETA 82, was used for the direct determination of lithium in ultra-high purity molybdenum trioxide by slurry sampling electrothermal atomic absorption spectrometry. Optimized conditions with regard to sample preparation, temperature program, possible spectral interferences and depressive effects of sample matrix were presented. Analytical performance of the conventional graphite atomizer and the tungsten atomizer were compared. Using the WETA 82 atomizer, a detection limit for lithium of 2 ng g -1 can be achieved, which is one order of magnitude lower than that for conventional graphite atomizers.

  14. Temporal variations in gas temperature in an atomization stage of cadmium and tellurium evaluated by using the two-line method in graphite furnace atomic absorption spectrometry.

    PubMed

    Shimabukuro, Haruki; Ashino, Tetsuya; Wagatsuma, Kazuaki

    2008-09-01

    In order to discuss the atomization process of an analyte element occurring in a graphite furnace for atomic absorption spectrometry, we measured variations in the characteristic temperature with the progress of an atomization stage, by using a two-line method under the assumption of a Boltzmann distribution. For this purpose, iron was chosen as the analyte element. Also, the atomic absorption of two iron atomic lines, Fe I 372.0 nm and Fe I 373.7 nm, was simultaneously monitored as a probe for the temperature determination. This method enables variations in the gas temperature to be directly traced, yielding a temperature distribution closely related to the diffusion behavior of the probe element in the furnace. This temperature variation was very different from the furnace wall temperatures, which were monitored in conventional temperature control for atomic absorption spectrometry. Correlations between the gas temperature and the charring/atomizing temperatures in the heating program of the furnace were investigated. The atomization of cadmium and tellurium was also investigated by a comparison between the gas temperature with the wall temperature of the furnace. The atomic absorption of cadmium or tellurium appeared to be apart from the absorption of iron while the gas temperature was still low. Therefore, the analyte atoms could be atomized through direct contact with the wall of the graphite furnace, which has a much higher temperature compared to the gas atmosphere during atomization. Their atomization would be caused by conductive heating from the furnace wall rather than by radiant heating in the furnace.

  15. Characterization of energetic and thermalized sputtered atoms in pulsed plasma using time-resolved tunable diode-laser induced fluorescence

    SciTech Connect

    Desecures, M.; Poucques, L. de; Easwarakhanthan, T.; Bougdira, J.

    2014-11-03

    In this work, a time-resolved tunable diode-laser (DL) induced fluorescence (TR-TDLIF) method calibrated by absorption spectroscopy has been developed in order to determine atom and flux velocity distribution functions (AVDF and FVDF) of the energetic and the thermalized atoms in pulsed plasmas. The experimental set-up includes a low-frequency (∼3 Hz) and high spectral-resolution DL (∼0.005 pm), a fast rise-time pulse generator, and a high power impulse magnetron sputtering (HiPIMS) system. The induced TR-TDLIF signal is recorded every 0.5 μs with a digital oscilloscope of a second-long trace. The technique is illustrated with determining the AVDF and the FVDF of a metastable state of the sputtered neutral tungsten atoms in the HiPIMS post-discharge. Gaussian functions describing the population of the four W isotopes were used to fit the measured TR-TDLIF signal. These distribution functions provide insight into transition from the energetic to thermalized regimes from the discharge onset. This technique may be extended with appropriate DLs to probe any species with rapidly changing AVDF and FVDF in pulsed and strongly oscillating plasmas.

  16. Two-photon dichroic atomic vapor laser lock using electromagnetically induced transparency and absorption

    SciTech Connect

    Becerra, F. E.; Willis, R. T.; Rolston, S. L.; Orozco, L. A.

    2009-07-15

    We demonstrate a technique to lock the frequency of a laser to a transition between two excited states in Rb vapor using a two-photon process in the presence of a weak magnetic field. We use a ladder configuration from specific hyperfine sublevels of the 5S{sub 1/2}, 5P{sub 3/2}, and 5D{sub 5/2} levels. This atomic configuration can show electromagnetically induced transparency and absorption processes. The error signal comes from the difference in the transparency or absorption felt by the two orthogonal polarizations of the probe beam. A simplified model is in good quantitative agreement with the observed signals for the experimental parameters. We have used this technique to lock the frequency of the laser up to 1.5 GHz off atomic resonance.

  17. Determination of tetraalkyllead compounds in gasoline by liquid chromatography-atomic absorption spectrometry

    USGS Publications Warehouse

    Messman, J.D.; Rains, T.C.

    1981-01-01

    A liquid chromatography-atomic absorption spectrometry (LC-AAS) hybrid analytical technique is presented for metal speciation measurements on complex liquid samples. The versatility and inherent metal selectivity of the technique are Illustrated by the rapid determination of five tetraalkyllead compounds in commercial gasoline. Separation of the individual tetraalkyllead species is achieved by reversed-phase liquid chromatography using an acetonitrile/water mobile phase. The effluent from the liquid Chromatograph Is introduced directly into the aspiration uptake capillary of the nebulizer of an air/acetylene flame atomic absorption spectrometer. Spectral interferences due to coeluting hydrocarbon matrix constituents were not observed at the 283.3-nm resonance line of lead used for analysis. Detection limits of this LC-AAS hydrid analytical technique, based on a 20-??L injection, are approximately 10 ng Pb for each tetraalkyllead compound.

  18. Determination of copper, zinc and iron in broncho-alveolar lavages by atomic absorption spectroscopy.

    PubMed

    Harlyk, C; Mccourt, J; Bordin, G; Rodriguez, A R; van der Eeckhout, A

    1997-11-01

    Concentrations of Zn, Cu and Fe were measured in 157 broncho-alveolar lavages (BAL), before and after centrifugation, collected at the Leuven University Hospital (Belgium). Zn was measured by flame-atomic absorption spectroscopy, using direct calibration, while Cu and Fe were determined by electrothermal atomic absorption spectroscopy, using the method of standard additions. For Fe only 56 samples were measured. Most of the studied elements are present in the liquid phase (supernatant). About 90% of Cu concentrations lie between 0 and 15 micrograms/kg, while 90% of Zn concentrations are lower than 230 micrograms/kg, with 30% between 30 and 70 micrograms/kg, and 50% between 100 and 200 micrograms/kg. There seems to be a reverse relationship between Cu and Zn levels with high Cu going along with low Zn and vice versa.

  19. Cadmium, copper, lead, and zinc determination in precipitation: A comparison of inductively coupled plasma atomic emission spectrometry and graphite furnace atomization atomic absorption spectrometry

    USGS Publications Warehouse

    Reddy, M.M.; Benefiel, M.A.; Claassen, H.C.

    1987-01-01

    Selected trace element analysis for cadmium, copper, lead, and zinc in precipitation samples by inductively coupled plasma atomic emission Spectrometry (ICP) and by atomic absorption spectrometry with graphite furnace atomization (AAGF) have been evaluated. This task was conducted in conjunction with a longterm study of precipitation chemistry at high altitude sites located in remote areas of the southwestern United States. Coefficients of variation and recovery values were determined for a standard reference water sample for all metals examined for both techniques. At concentration levels less than 10 micrograms per liter AAGF analyses exhibited better precision and accuracy than ICP. Both methods appear to offer the potential for cost-effective analysis of trace metal ions in precipitation. ?? 1987 Springer-Verlag.

  20. Literature study of microwave-assisted digestion using electrothermal atomic absorption spectrometry.

    PubMed

    Chakraborty, R; Das, A K; Cervera, M L; De La Guardia, M

    1996-05-01

    The literature on the use of microwave-assisted digestion procedures for subsequent sample analysis by means of electrothermal atomic absorption spectrometry (ETAAS) is reviewed. The literature survey reveals that this digestion technique has been applied mainly for biological materials. The elements most extensively determined by this method are cadmium and lead followed by copper, chromium, nickel and iron. The microwave digestion conditions, ETAAS furnace programmes and analytical details of the developed methodologies have been carefully revised.

  1. Speciation analysis of arsenic in biological matrices by automated hydride generation-cryotrapping-atomic absorption spectrometry with multiple microflame quartz tube atomizer (multiatomizer).

    EPA Science Inventory

    This paper describes an automated system for the oxidation state specific speciation of inorganic and methylated arsenicals by selective hydride generation - cryotrapping- gas chromatography - atomic absorption spectrometry with the multiatomizer. The corresponding arsines are ge...

  2. An atomic-absorption spectrometer with an electrothermal atomizer in a magnetic field

    SciTech Connect

    Eristavi, V.D; Ivanov, V.K.; Sadagov, Y.M.; Sharashidze, P.A.

    1986-08-01

    This paper describes a system for correcting unselective interference. The system enables one to amplify the preparation of specimens of complicated composition, and it increases the accuracy at the expense of only a very slight sensitivity loss. The Zeeman AA spectrometer with electrothermal atomizer is shown and is based on the optical system of an S-302 AA spectrometer. The resonant-radiation sources were VSB-2 electrodeless high-frequency lamps or 1SP-1 hollow-cathode ones supplied with dc. The system for correcting for unselective interference enables one to simplify the preparation of specimens of complicated composition and it increases the accuracy at the expense of only a very slight sensitivity loss.

  3. Determination of platinum originated from antitumoral drugs in human urine by atomic absorption spectrometric methods.

    PubMed

    da Costa, Anilton Coelho; Vieira, Mariana Antunes; Luna, Aderval Severino; de Campos, Reinaldo Calixto

    2010-10-15

    Cisplatin and carboplatin are the most common platinum-based drugs used in cancer treatment. Pharmacokinetic investigations, the evaluation of the body burden during the treatment, as well as baseline levels of platinum in humans have attracted great interest. Thus, accurate analytical methods for fast and easy Pt monitoring in clinical samples become necessary. In the present study atomic absorption spectrometric methods for the determination of platinum in the forms of cisplatin and carboplatin in human urine were investigated. Platinum, in these different forms, could be determined in urine, after simple sample dilution. Regarding electrothermal atomic absorption spectrometry, the optimum parameters were defined by a central composite design optimization. Multiplicative matrix effects were overcome by using a mixture of HCl and NaCl as modifier. The limit of detection (LOD) was 0.004 mgL(-1) of platinum in the original sample. For the analysis of more concentrated samples, high resolution continuous source flame atomic absorption spectrometry was also investigated. Flame conditions were optimized by a multivariate D-optimal design, using as response the sum of the analyte addition calibration slopes and their standard deviations. Matrix matched external calibration with PtCl(2) calibration solutions, was possible, and the LOD was 0.06 mgL(-1) in the original sample. The results obtained by the proposed procedures were also in good agreement with those obtained by an independent comparative procedure.

  4. Solvent effects on the absorption and fluorescence spectra of rhaponticin: Experimental and theoretical studies

    NASA Astrophysics Data System (ADS)

    Sun, Yang; Liang, Xuhua; Zhao, Yingyong; Fan, Jun

    2013-02-01

    Rhaponticin (RH) possesses a variety of pharmacological activities including potent antitumor, antitumor-promoting, antithrombotic, antioxidant and vasorelaxant effects. The fundamental photophysics of RH is not well understood. In this work, solvent effect on the photoluminescence behavior of RH was studied by fluorescence and absorption spectra. The bathchromic shift was observed in absorption and fluorescence spectra with the increase of solvents polarity, which implied that transition involved was π → π*. A quantitative estimation of the contribution from different solvatochromic parameters, like normalized transition energy value (ETN), was made using the linear stokes shift (Δν) relationship based on the Lippert-Suppan equation. The ground state and excited state dipole moments were calculated by quantum-mechanical second-order perturbation method as a function of the dielectric constant (ɛ) and refractive index (n). The result was found to be 2.23 and 3.67 D in ground state and excited state respectively. The density functional theory (DFT) was used to obtain the most stable structure, electronic excitation energy, dipole moments and charge distribution. The analysis revealed that the RH exhibited strong photoinduced intramolecular charge transfer (ICT), and the intermolecular hydrogen bonding ability of the solvent was the most important parameter to characterize the photophysics behavior of RH. The hydrogen bonding effect occurred at the localized electron-acceptor oxygen at the glycoside bond. The experimental and theoretical results would help us better understand the photophysical properties of RH.

  5. Self-assembly based plasmonic arrays tuned by atomic layer deposition for extreme visible light absorption.

    PubMed

    Hägglund, Carl; Zeltzer, Gabriel; Ruiz, Ricardo; Thomann, Isabell; Lee, Han-Bo-Ram; Brongersma, Mark L; Bent, Stacey F

    2013-07-10

    Achieving complete absorption of visible light with a minimal amount of material is highly desirable for many applications, including solar energy conversion to fuel and electricity, where benefits in conversion efficiency and economy can be obtained. On a fundamental level, it is of great interest to explore whether the ultimate limits in light absorption per unit volume can be achieved by capitalizing on the advances in metamaterial science and nanosynthesis. Here, we combine block copolymer lithography and atomic layer deposition to tune the effective optical properties of a plasmonic array at the atomic scale. Critical coupling to the resulting nanocomposite layer is accomplished through guidance by a simple analytical model and measurements by spectroscopic ellipsometry. Thereby, a maximized absorption of light exceeding 99% is accomplished, of which up to about 93% occurs in a volume-equivalent thickness of gold of only 1.6 nm. This corresponds to a record effective absorption coefficient of 1.7 × 10(7) cm(-1) in the visible region, far exceeding those of solid metals, graphene, dye monolayers, and thin film solar cell materials. It is more than a factor of 2 higher than that previously obtained using a critically coupled dye J-aggregate, with a peak width exceeding the latter by 1 order of magnitude. These results thereby substantially push the limits for light harvesting in ultrathin, nanoengineered systems.

  6. Time-resolved Absorption Spectra of the Laser-dressed Hydrogen Atom

    NASA Astrophysics Data System (ADS)

    Murakami, Mitsuko; Chu, Shih-I.

    2013-05-01

    A theoretical study of the transient absorption spectra for the laser-dressed hydrogen atom based on the accurate numerical solution of the time-dependent Schrödinger equation is presented. The timing of absorption is controlled by the time delay between an isolated extreme ultraviolet (XUV) pulse and a dressing infrared (IR) field. We identify two different kinds of physical processes in the spectra. One is the formation of dressed states, signified by the appearance of sidebands between the XUV absorption lines separated by one IR-photon energy. We show that their population is maximized when the XUV pulse coincides with the zero-crossing of the IR field, and that their energy can be manipulated by using a chirped IR field. The other process is the dynamical AC Stark shift induced by the IR field and probed by the XUV pulse. Our calculations indicate that the accidental degeneracy of the hydrogen atom leads to the multiple splittings of each XUV absorption line whose separations change in response to a slowly-varying IR envelope. Furthermore, we observe the Autler-Townes doublets for the n=2 and 3 states using the 656 nm dressing field, but their separation does not agree with the prediction by the conventional 3-level model that neglects the dynamical AC Stark effects.

  7. Studies on mass energy-absorption coefficients and effective atomic energy-absorption cross sections for carbohydrates

    NASA Astrophysics Data System (ADS)

    Ladhaf, Bibifatima M.; Pawar, Pravina P.

    2015-04-01

    We measured here the mass attenuation coefficients (μ/ρ) of carbohydrates, Esculine (C15H16O9), Sucrose (C12H22O11), Sorbitol (C6H14O6), D-Galactose (C6H12O6), Inositol (C6H12O6), D-Xylose (C5H10O5) covering the energy range from 122 keV up to 1330 keV photon energies by using gamma ray transmission method in a narrow beam good geometry set-up. The gamma-rays were detected using NaI(Tl) scintillation detection system with a resolution of 8.2% at 662 keV. The attenuation coefficient data were then used to obtain the total attenuation cross-section (σtot), molar extinction coefficients (ε), mass-energy absorption coefficients (μen/ρ) and effective (average) atomic energy-absorption cross section (σa,en) of the compounds. These values are found to be in good agreement with the theoretical values calculated based on XCOM data.

  8. Variations of Positive and Negative Dispersions in Both Highly and Weakly Absorptive Atomic Systems

    NASA Astrophysics Data System (ADS)

    Abi-Salloum, Tony; Snell, Scott; Davis, Jon; Narducci, Frank

    2011-05-01

    Positive and negative dispersive media are essential in subluminal, superluminal and negative group velocity pulse propagation applications. Three-level atomic media at resonance, especially the Lambda configuration, are positively dispersive and transparent. In contrast, two-level atomic systems are negatively dispersive and opaque. In this work we study higher level atomic systems comprised of three fields coupled to three levels (double lambda) or four levels (N-Scheme). We explore the systems of interest for critical features such as negative dispersion and transparency, a combination that is needed in numerous applications, e.g. optical gyroscopes. We solve the time dependent equations perturbatively and compare them to well established behavior in three-level systems. Some of the results are analyzed in terms of resonances which control the different features of the observed dispersive and absorptive behaviors.

  9. Spectral fluorescence signature techniques and absorption measurements for continuous monitoring of biofuel-producing microalgae cultures

    NASA Astrophysics Data System (ADS)

    Martín de la Cruz, M. C.; Gonzalez Vilas, L.; Yarovenko, N.; Spyrakos, E.; Torres Palenzuela, J. M.

    2013-08-01

    Biofuel production from microalgae can be both sustainable and economically viable. Particularly in the case of algal growth in wastewater an extra benefit is the removal or biotransformation of pollutants from these types of waters. A continuous monitoring system of the microalgae status and the concentration of different wastewater contaminants could be of great help in the biomass production and the water characterisation. In this study we present a system where spectral fluorescence signature (SFS) techniques are used along with absorption measurements to monitor microalgae cultures in wastewater and other mediums. This system aims to optimise the microalgae production for biofuel applications or other uses and was developed and tested in prototype indoor photo-bioreactors at the University of Vigo. SFS techniques were applied using the fluorescence analyser INSTAND-SCREENER developed by Laser Diagnostic Instruments AS. INSTAND-SCREENER permits wavelength scanning in two modes, one in UV and another in VIS. In parallel, it permits the on-line monitoring and rapid analysis of both water quality and phytoplankton status without prior treatment of the sample. Considering that different contaminants and microalgae features (density, status etc.) have different spectral signatures of fluorescence and absorption properties, it is possible to characterise them developing classification libraries. Several algorithms were used for the classification. The implementation of this system in an outdoor raceway reactor in a Spanish wastewater treatment plant is also discussed. This study was part of the Project EnerBioAlgae (http://www.enerbioalgae.com/), which was funded by the Interreg SUDOE and led by the University of Vigo.

  10. Absorption and fluorescence spectroscopic characterization of BLUF domain of AppA from Rhodobacter sphaeroides

    NASA Astrophysics Data System (ADS)

    Zirak, P.; Penzkofer, A.; Schiereis, T.; Hegemann, P.; Jung, A.; Schlichting, I.

    2005-08-01

    The BLUF domain of the transcriptional anti-repressor protein AppA from the non-sulfur anoxyphototrophic purple bacterium Rhodobacter sphaeroides was characterized by absorption and emission spectroscopy. The BLUF domain constructs AppA 148 (consisting of amino-acid residues 1-148) and AppA 126 (amino-acid residues 1-126) are investigated. The cofactor of the investigated domains is found to consist of a mixture of the flavins riboflavin, FMN, and FAD. The dark-adapted domains exist in two different active receptor conformations (receptor states) with different sub-nanosecond fluorescence lifetimes (BLUF r,f and BLUF r,sl) and a small non-interacting conformation (BLUF nc). The active receptor conformations are transformed to putative signalling states (BLUF s,f and BLUF s,sl) of low fluorescence efficiency and picosecond fluorescence lifetime by blue-light excitation (light-adapted domains). In the dark at room temperature both signalling states recover back to the initial receptor states with a time constant of about 17 min. A quantum yield of signalling state formation of about 25% was determined by intensity dependent transmission measurements. A photo-cycle scheme is presented including photo-induced charge transfer complex formation, charge recombination, and protein binding pocket reorganisation.

  11. Determination of tellurium by hydride generation with in situ trapping flame atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Matusiewicz, Henryk; Krawczyk, Magdalena

    2007-03-01

    The analytical performance of coupled hydride generation — integrated atom trap (HG-IAT) atomizer flame atomic absorption spectrometry (FAAS) system was evaluated for determination of Te in reference material (GBW 07302 Stream Sediment), coal fly ash and garlic. Tellurium, using formation of H 2Te vapors, is atomized in air-acetylene flame-heated IAT. A new design HG-IAT-FAAS hyphenated technique that would exceed the operational capabilities of existing arrangements (a water-cooled single silica tube, double-slotted quartz tube or an "integrated trap") was investigated. An improvement in detection limit was achieved compared with using either of the above atom trapping techniques separately. The concentration detection limit, defined as 3 times the blank standard deviation (3 σ), was 0.9 ng mL - 1 for Te. For a 2 min in situ pre-concentration time (sample volume of 2 mL), sensitivity enhancement compared to flame AAS, was 222 fold, using the hydride generation — atom trapping technique. The sensitivity can be further improved by increasing the collection time. The precision, expressed as RSD, was 7.0% ( n = 6) for Te. The designs studied include slotted tube, single silica tube and integrated atom trap-cooled atom traps. The accuracy of the method was verified using a certified reference material (GBW 07302 Stream Sediment) by aqueous standard calibration curves. The measured Te contents of the reference material was in agreement with the information value. The method was successfully applied to the determination of tellurium in coal fly ash and garlic.

  12. Spontaneous Decay and Atomic Fluorescence Near a Metal Surface of an Absorbing Dielectric.

    DTIC Science & Technology

    1987-10-01

    classical and quantum mechanics the radiation field must obey Maxwell’s equations , and therefore the spatial dependence of the field is identical in both...theories. In the classical paper by Chance et alI the atomic lifetimes near a dielectric were found from semiclassical considerations. Other... semiclassical theories of fluorescence the dipole moment is merely a vector in configuration space, which can be given an arbitrary direction. One then

  13. Fluorescent atom coincidence spectroscopy of extremely neutron-deficient barium isotopes

    NASA Astrophysics Data System (ADS)

    Wells, S. A.; Evans, D. E.; Griffith, J. A. R.; Eastham, D. A.; Groves, J.; Smith, J. R. H.; Tolfree, D. W. L.; Warner, D. D.; Billowes, J.; Grant, I. S.; Walker, P. M.

    1988-09-01

    Fluorescent atom coincidence spectroscopy (FACS) has been used to measure the nuclear mean square radii and moments of the extremely neutron-deficient isotopes 120-124Ba. At N=65 an abrupt change in nuclear mean square charge radii is observed which can be understood in terms of the occupation of the spin-orbit partner g7/25/2[413] neutron and g9/29/2[404] proton orbitals and the consequent enhancement of the n-p interaction.

  14. Dopant activation mechanism of Bi wire-δ-doping into Si crystal, investigated with wavelength dispersive fluorescence x-ray absorption fine structure and density functional theory.

    PubMed

    Murata, Koichi; Kirkham, Christopher; Shimomura, Masaru; Nitta, Kiyofumi; Uruga, Tomoya; Terada, Yasuko; Nittoh, Koh-Ichi; Bowler, David R; Miki, Kazushi

    2017-04-20

    We successfully characterized the local structures of Bi atoms in a wire-δ-doped layer (1/8 ML) in a Si crystal, using wavelength dispersive fluorescence x-ray absorption fine structure at the beamline BL37XU, in SPring-8, with the help of density functional theory calculations. It was found that the burial of Bi nanolines on the Si(0 0 1) surface, via growth of Si capping layer at 400 °C by molecular beam epitaxy, reduced the Bi-Si bond length from [Formula: see text] to [Formula: see text] Å. We infer that following epitaxial growth the Bi-Bi dimers of the nanoline are broken, and the Bi atoms are located at substitutional sites within the Si crystal, leading to the shorter Bi-Si bond lengths.

  15. Dopant activation mechanism of Bi wire-δ-doping into Si crystal, investigated with wavelength dispersive fluorescence x-ray absorption fine structure and density functional theory

    NASA Astrophysics Data System (ADS)

    Murata, Koichi; Kirkham, Christopher; Shimomura, Masaru; Nitta, Kiyofumi; Uruga, Tomoya; Terada, Yasuko; Nittoh, Koh-ichi; Bowler, David R.; Miki, Kazushi

    2017-04-01

    We successfully characterized the local structures of Bi atoms in a wire-δ-doped layer (1/8 ML) in a Si crystal, using wavelength dispersive fluorescence x-ray absorption fine structure at the beamline BL37XU, in SPring-8, with the help of density functional theory calculations. It was found that the burial of Bi nanolines on the Si(0 0 1) surface, via growth of Si capping layer at 400 °C by molecular beam epitaxy, reduced the Bi–Si bond length from 2.79+/- 0.01~{\\mathring{\\text{A}}} to 2.63+/- 0.02 Å. We infer that following epitaxial growth the Bi–Bi dimers of the nanoline are broken, and the Bi atoms are located at substitutional sites within the Si crystal, leading to the shorter Bi–Si bond lengths.

  16. Investigation of chemical modifiers for phosphorus in a graphite furnace using high-resolution continuum source atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Lepri, Fábio G.; Dessuy, Morgana B.; Vale, Maria Goreti R.; Borges, Daniel L. G.; Welz, Bernhard; Heitmann, Uwe

    2006-08-01

    Phosphorus is not one of the elements that are typically determined by atomic absorption spectrometry, but this technique nevertheless offers several advantages that make it attractive, such as the relatively great freedom from interferences. As the main resonance lines for phosphorus are in the vacuum-ultraviolet, inaccessible by conventional atomic absorption spectrometry equipment, Ĺvov and Khartsyzov proposed to use the non-resonance doublet at 213.5 / 213.6 nm. Later it turned out that with conventional equipment it is necessary to use a chemical modifier in order to get reasonable sensitivity, and lanthanum was the first one suggested for that purpose. In the following years more than 30 modifiers have been proposed for the determination of this element, and there is no consensus about the best one. In this work high-resolution continuum source atomic absorption spectrometry has been used to investigate the determination of phosphorus without a modifier and with the addition of selected modifiers of very different nature, including the originally recommended lanthanum modifier, several palladium-based modifiers and sodium fluoride. As high-resolution continuum source atomic absorption spectrometry is revealing the spectral environment of the analytical line at high resolution, it became obvious that without the addition of a modifier essentially no atomic phosphorus is formed, even at 2700 °C. The absorption measured with line source atomic absorption spectrometry in this case is due to the PO molecule, the spectrum of which is overlapping with the atomic line. Palladium, with or without the addition of calcium or ascorbic acid, was found to be the only modifier to produce almost exclusively atomic phosphorus. Lanthanum and particularly sodium fluoride produced a mixture of P and PO, depending on the atomization temperature. This fact can explain at least some of the discrepancies found in the literature and some of the phenomena observed in the

  17. Few-atom fluorescent silver clusters assemble at programmed sites on DNA nanotubes.

    PubMed

    O'Neill, Patrick R; Young, Kevin; Schiffels, Daniel; Fygenson, Deborah K

    2012-11-14

    We show that DNA hairpins template the site-specific assembly of fluorescent few-atom Ag clusters on DNA nanotubes. Fluorescent clusters form only at hairpin sites and not on the double-stranded DNA scaffold, allowing for spatially programmed self-assembly. Ag clusters synthesized on hairpins protruding from DNA nanotubes can have nearly identical fluorescence spectra to those synthesized on free hairpins of identical sequence. Analysis of the stepwise photobleaching of individual clusters suggests a chemical yield of ~45%. Given the well-established sequence-specific optical properties of DNA stabilized Ag clusters, these results point the way toward high yield assembly of metal cluster fluorophores with control over spectra as well as spatial arrangement.

  18. The estimation of the possibilities of synchrotron radiation X-ray fluorescent analysis and atomic specrometry for the bone's elemental composition determination

    NASA Astrophysics Data System (ADS)

    Gonchar, A. M.; Kolmogorov, U. P.; Gladkikh, E. A.; Shuvaeva, O. V.; Beisel, N. F.; Kolosova, N. G.

    2005-05-01

    Possibilities of multielemental highly sensitive techniques of analysis have been studied: synchrotron radiation X-ray fluorescence analysis (SR XFA), and atomic emission spectrometry with inductively bound plasma (ISP) and atomic absorption spectrometry (AAS) with flame (air-acetylene) atomization for assay of element composition of bone tissue with minimal preparation procedure. Results of comparative studies of elemental composition of bone tissue samples from experimental animals with inherited accelerated aging (rats of OXYS strain) using the SR XFA, ISP and AAS techniques are presented. It is shown that there exists in principle a possibility of assay of 22 biologically important essential macro- and trace elements within the range of 1.0-100,000 μg/g with a mean square analysis error of no more them 10-15% when using SR XFA.

  19. Simultaneous differential spinning disk fluorescence optical sectioning microscopy and nanomechanical mapping atomic force microscopy

    SciTech Connect

    Miranda, Adelaide; De Beule, Pieter A. A.

    2015-09-15

    Combined microscopy techniques offer the life science research community a powerful tool to investigate complex biological systems and their interactions. Here, we present a new combined microscopy platform based on fluorescence optical sectioning microscopy through aperture correlation microscopy with a Differential Spinning Disk (DSD) and nanomechanical mapping with an Atomic Force Microscope (AFM). The illumination scheme of the DSD microscope unit, contrary to standard single or multi-point confocal microscopes, provides a time-independent illumination of the AFM cantilever. This enables a distortion-free simultaneous operation of fluorescence optical sectioning microscopy and atomic force microscopy with standard probes. In this context, we discuss sample heating due to AFM cantilever illumination with fluorescence excitation light. Integration of a DSD fluorescence optical sectioning unit with an AFM platform requires mitigation of mechanical noise transfer of the spinning disk. We identify and present two solutions to almost annul this noise in the AFM measurement process. The new combined microscopy platform is applied to the characterization of a DOPC/DOPS (4:1) lipid structures labelled with a lipophilic cationic indocarbocyanine dye deposited on a mica substrate.

  20. Determination of total magnesium in biological samples using electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Hulanicki, Adam; Godlewska, Beata; Brzóska, Malgorzata

    1995-11-01

    Magnesium content is an important diagnostic parameter in medicine. It is recognized that its determination in one compartment is not sufficient for reliable information about the magnesium status in the body. In addition to the common procedures of magnesium determination in blood by flame atomic absorption spectrometry, the procedure of electrothermal atomization has also been developed and applied to the analysis of blood fractions, mononuclear cells and isolated nuclei of liver cells. Electrothermal atomization is preferred in cases where the sample size is limited and the magnesium content low. The total errors are in the order of 3-4%. Various techniques of sample pretreatment have been tested and direct dilution with 0.05 mol l -1 nitric acid was optimal when the samples were not mineralized. The calibration graph based on standards containing albumin was found to give the best results, as the form of magnesium in the samples may influence the ashing and atomization processes. Good agreement was obtained for determination of magnesium in standard serum. The results are compared with those obtained by the standard flame atomization technique.

  1. Influence of transannular interaction over absorption and fluorescent properties of [2.2] paracyclophane and its phenyl derivatives

    NASA Astrophysics Data System (ADS)

    Nurmukhametov, R. N.; Shapovalov, A. V.; Antonov, D. Yu.

    2016-12-01

    A significant bathochromic shift of the fluorescent and long-wavelength absorption bands of [2.2] paracyclophane comparing to corresponding bands of alkyl-benzenes is due to a strong transannular interaction, resulting in formation of a principally new excited state of lower energy. It is concluded that the fluorescent levels for alkylbenzene excimers and for the macrocycle are of the same nature. Analysis of [2.2] paracyclophane mono- and diphenylderivatives spectra shows that their intensive absorption bands (230-310 nm) are originated from electron transitions of biphenyl groups and weak long wavelength absorption (310-340 nm) and fluorescent bands are governed by the same electron transitions between ground and excimer-like excited states as in the case of non-substituted macrocycle.

  2. Method 200.12 - Determination of Trace Elements in Marine Waters by StabilizedTemperature Graphite Furnace Atomic Absorption

    EPA Science Inventory

    This method provides procedures for the determination of total recoverable elements by graphite furnace atomic absorption (GFAA) in marine waters, including estuarine, ocean and brines with salinities of up to 35 ppt.

  3. Low-resolution continuum source simultaneous multi-element electrothermal atomic absorption spectrometry: steps into practice

    NASA Astrophysics Data System (ADS)

    Katskov, Dmitri

    2015-03-01

    The theory and practical problems of continuum source simultaneous multi-element electrothermal atomic absorption spectrometry (SMET AAS) are discussed by the example of direct analysis of underground water. The experimental methodology is based on pulse vaporization of the sample in a fast heated graphite tube and measurement of transient absorption of continuum spectrum radiation from D2 and Xe lamps within 200-400 nm wavelengths range with a low resolution spectral instrument and linear charge-coupled device. The setup permits the acquisition of 200 spectra during 1 s atomization pulse. Respective data matrix absorbance vs wavelength/time is employed for the quantification of elements in the sample. The calculation algorithm developed includes broad band and continuum background correction, linearization of function absorbance vs. concentration of atomic vapor and integration of thus modified absorbance at the resonance lines of the elements to be determined. Practical application shows that the method can be employed for the direct simultaneous determination of about 20 elements above microgram per liter level within 3-5 orders of the magnitude concentration range. The investigated sources of measurement errors are mainly associated with the atomization and vapor transportation problems, which are aggravated for the simultaneous release of major and minor sample constituents. Respective corrections concerning the selection of analytical lines, optimal sampling volume, matrix modification and cleaning of the atomizer have been introduced in the SMET AAS analytical technology. Under the optimized experimental conditions the calibration curves in Log-Log coordinates for all the investigated analytes in the single or multi-element reference solutions are approximated by the first order equations. The use of these equations as permanent characteristics of the setup enables instant quantification of Al, Ca, Co, Cr, Cu, Fe, Mg, Mn and Ni in the underground water

  4. Cascade splitting of two atomic energy levels due to multiphoton absorption

    NASA Astrophysics Data System (ADS)

    Ruan, Ya-Ping; Jia, Feng-Dong; Sun, Zhen; Lv, Shuang-Fei; Qing, Bo; Huang, Wei; Xue, Ping; Xu, Xiang-Yuan; Dai, Xing-Can; Zhong, Zhi-Ping

    2014-09-01

    We have theoretically and experimentally studied the spectroscopic properties of dressed levels in a strong monochromatic field, and propose a model of cascade splitting of two atomic energy levels. In this model two related dressed levels can be split into four levels, and transitions connecting four new levels will constitute spectroscopic structures. Two types of proof-in-principle experiments are performed to verify the model. One experiment measures the probe absorption spectra of a degenerate two-level atomic system with two strong monochromatic coupling fields. The system consists of 52S1/2,F=2 and 52P3/2,F'=3 states of Rb87 atoms in a magneto-optical trap (MOT) as well as the cooling beams and an additional coupling field. New spectral features are observed and proven to be due to the transitions of new levels generated by splitting of the dressed levels. The other experiment measures the pump-probe spectra in a degenerate two-level atomic system with one strong monochromatic coupling field. The system consists of 52S1/2,F=2 and 52P3/2,F'=3 states of the Rb87 atom in a magneto-optical trap and one coupling field. We have observed spectral features that obviously differ from the prediction that comes from the two-level dressed-atom approach. They cannot be explained by existing theories. The model of cascade splitting of two atomic energy levels is employed to explain the observations in these two types of experiments.

  5. Solution and slurry sampling electrothermal atomic absorption spectrometry for the analysis of high purity quartz

    NASA Astrophysics Data System (ADS)

    Hauptkorn, Susanne; Krivan, Viliam

    1996-07-01

    A slurry sampling electrothermal atomic absorption spectrometry (ETAAS) method for the determination of Al, Cr, Cu, Fe, K, Li, Mg, Mn and Na at trace and ultratrace level in high purity quartz samples has been developed. The influence of atomization temperature, internal gas flow during atomization and carbide modification of the graphite tube on the background absorption has been studied. Simple quantification via calibration curves, recorded with aqueous standards, is possible for all elements except Al. The performance and the accuracy of the slurry sampling technique are compared to those of the analysis of hydrofluoric acid digests. With both methods, the blanks could be substantially reduced by minimization of sample handling. Because of essentially higher applicable sample portions, the solution technique provides lower limits of detection for all elements excluding Al, Na and K. For the slurry sampling technique, the achievable limits of detection are in the range of 2 (Mg) to 500 (Fe) ng g -1 and for the solution technique, they are between 0.4 (Mg) and 500 (Al) ng g -1. Thus, both developed methods are well suited for ultratrace analysis of high purity quartz for microelectronic applications. The results obtained by these two ETAAS techniques are compared with those of independent methods including neutron activation analysis.

  6. Determination of Mercury in Aqueous and Geologic Materials by Continuous Flow-Cold Vapor-Atomic Fluorescence Spectrometry (CVAFS)

    USGS Publications Warehouse

    Hageman, Philip L.

    2007-01-01

    New methods for the determination of total mercury in geologic materials and dissolved mercury in aqueous samples have been developed that will replace the methods currently (2006) in use. The new methods eliminate the use of sodium dichromate (Na2Cr2O7 ?2H2O) as an oxidizer and preservative and significantly lower the detection limit for geologic and aqueous samples. The new methods also update instrumentation from the traditional use of cold vapor-atomic absorption spectrometry to cold vapor-atomic fluorescence spectrometry. At the same time, the new digestion procedures for geologic materials use the same size test tubes, and the same aluminum heating block and hot plate as required by the current methods. New procedures for collecting and processing of aqueous samples use the same procedures that are currently (2006) in use except that the samples are now preserved with concentrated hydrochloric acid/bromine monochloride instead of sodium dichromate/nitric acid. Both the 'old' and new methods have the same analyst productivity rates. These similarities should permit easy migration to the new methods. Analysis of geologic and aqueous reference standards using the new methods show that these procedures provide mercury recoveries that are as good as or better than the previously used methods.

  7. Determination of lead in wine by hydride generation atomic fluorescence spectrometry in the presence of hexacyanoferrate(III).

    PubMed

    Karadjova, Irina B; Lampugnani, Leonardo; D'Ulivo, Alessandro; Onor, Massimo; Tsalev, Dimiter L

    2007-06-01

    A rapid, accurate, and precise method is described for the determination of Pb in wine using continuous-flow hydride generation atomic fluorescence spectrometry (CF-HGAFS). Sample pretreatment consists of ten-fold dilution of wine followed by direct plumbane generation in the presence of 0.1 mol L(-1) HCl and 1% m/v K(3)[Fe(CN)(6)] with 1% m/v NaBH(4) as reducing agent. An aqueous standard calibration curve is recommended for Pb quantification in wine sample. The method provides a limit of detection and a limit of quantification of 0.3 microg L(-1) and 1 microg L(-1), respectively. The relative standard deviation varies between 2-6% (within-run) and 4-11% (between-run) at 3-30 microg L(-1) Pb levels in wine. Good agreement has been demonstrated between results obtained by CF-HGAFS and direct electrothermal atomic absorption spectrometry in analyses of red and white wines within the concentration range of 9.2-25.8 microg L(-1) Pb.

  8. Absorption, fluorescence, and acid-base equilibria of rhodamines in micellar media of sodium dodecyl sulfate

    NASA Astrophysics Data System (ADS)

    Obukhova, Elena N.; Mchedlov-Petrossyan, Nikolay O.; Vodolazkaya, Natalya A.; Patsenker, Leonid D.; Doroshenko, Andrey O.; Marynin, Andriy I.; Krasovitskii, Boris M.

    2017-01-01

    Rhodamine dyes are widely used as molecular probes in different fields of science. The aim of this paper was to ascertain to what extent the structural peculiarities of the compounds influence their absorption, emission, and acid-base properties under unified conditions. The acid-base dissociation (HR+ ⇄ R + H+) of a series of rhodamine dyes was studied in sodium n-dodecylsulfate micellar solutions. In this media, the form R exists as a zwitterion R±. The indices of apparent ionization constants of fifteen rhodamine cations HR+ with different substituents in the xanthene moiety vary within the range of pKaapp = 5.04 to 5.53. The distinct dependence of emission of rhodamines bound to micelles on pH of bulk water opens the possibility of using them as fluorescent interfacial acid-base indicators.

  9. Invited Review Article: Imaging techniques for harmonic and multiphoton absorption fluorescence microscopy

    PubMed Central

    Carriles, Ramón; Schafer, Dawn N.; Sheetz, Kraig E.; Field, Jeffrey J.; Cisek, Richard; Barzda, Virginijus; Sylvester, Anne W.; Squier, Jeffrey A.

    2009-01-01

    We review the current state of multiphoton microscopy. In particular, the requirements and limitations associated with high-speed multiphoton imaging are considered. A description of the different scanning technologies such as line scan, multifoci approaches, multidepth microscopy, and novel detection techniques is given. The main nonlinear optical contrast mechanisms employed in microscopy are reviewed, namely, multiphoton excitation fluorescence, second harmonic generation, and third harmonic generation. Techniques for optimizing these nonlinear mechanisms through a careful measurement of the spatial and temporal characteristics of the focal volume are discussed, and a brief summary of photobleaching effects is provided. Finally, we consider three new applications of multiphoton microscopy: nonlinear imaging in microfluidics as applied to chemical analysis and the use of two-photon absorption and self-phase modulation as contrast mechanisms applied to imaging problems in the medical sciences. PMID:19725639

  10. Advanced glycation end products in hemodialysates as fluorescent and optical absorption markers of patients mortality

    NASA Astrophysics Data System (ADS)

    Kuznetsov, A.; Frorip, A.; Maiste, A.; Ots-Rosenberg, M.; Sünter, A.; Sablonin, J.; Vasil'chenko, J.

    2014-10-01

    Hemodialysate (HD) samples collected from the end stage renal disease patients (ESRD Pts) were used for search for possible correlation between the intensity of HD visible auto-fluorescence (VF) detected at 420 nm as well as their optical absorption at 320 nm and the mortality events among the Pts. Previous but strongly promising correlations has been found in both cases which deserve further supplementation and examination. Investigation of possible influence of quenchers onto the VF intensity has been carried out. Endogenous inorganic ions present in biological fluids (serum, urine and HD) (Na, K, Ca, Mg and ammonia) do not affect the VF intensity remarkably but exogenous Al ions do that indirectly and specifically. Carbon based entities (nanoparticles of graphene type, humins) quench the VF effectively according to the Stern-Volmer law. The quenching phenomena and influence of aluminium must be taken into account by the further investigations, medical care and nutrition.

  11. Invited review article: Imaging techniques for harmonic and multiphoton absorption fluorescence microscopy.

    PubMed

    Carriles, Ramón; Schafer, Dawn N; Sheetz, Kraig E; Field, Jeffrey J; Cisek, Richard; Barzda, Virginijus; Sylvester, Anne W; Squier, Jeffrey A

    2009-08-01

    We review the current state of multiphoton microscopy. In particular, the requirements and limitations associated with high-speed multiphoton imaging are considered. A description of the different scanning technologies such as line scan, multifoci approaches, multidepth microscopy, and novel detection techniques is given. The main nonlinear optical contrast mechanisms employed in microscopy are reviewed, namely, multiphoton excitation fluorescence, second harmonic generation, and third harmonic generation. Techniques for optimizing these nonlinear mechanisms through a careful measurement of the spatial and temporal characteristics of the focal volume are discussed, and a brief summary of photobleaching effects is provided. Finally, we consider three new applications of multiphoton microscopy: nonlinear imaging in microfluidics as applied to chemical analysis and the use of two-photon absorption and self-phase modulation as contrast mechanisms applied to imaging problems in the medical sciences.

  12. ADVANCED APPROACHES TO ARSINE ATOMIZATION FOR AS SPECIATION BY CRYOFOCUSING WITH ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE DETECTORS

    EPA Science Inventory

    Human metabolism of inorganic arsenic (iAs) yields methylated arsenicals that contain arsenic in +3 or +5 oxidation state. Trivalent methylated arsenicals are significantly more toxic than their pentavalent counterparts. Therefore, determination of tri- and pentavalent forms of m...

  13. Solvent effects on the steady-state absorption and fluorescence spectra of uracil, thymine and 5-fluorouracil.

    PubMed

    Gustavsson, Thomas; Sarkar, Nilmoni; Bányász, Akos; Markovitsi, Dimitra; Improta, Roberto

    2007-01-01

    We report a comparison of the steady-state absorption and fluorescence spectra of three representative uracil derivatives (uracil, thymine and 5-fluorouracil) in alcoholic solutions. The present results are compared with those from our previous experimental and computational studies of the same compounds in water and acetonitrile. The effects of solvent polarity and hydrogen bonding on the spectra are discussed in the light of theoretical predictions. This comparative analysis provides a more complete picture of the solvent effects on the absorption and fluorescence properties of pyrimidine nucleobases, with special emphasis on the mechanism of the excited state deactivation.

  14. Solvent dependence of two-photon absorption spectra of the enhanced green fluorescent protein (eGFP) chromophore

    NASA Astrophysics Data System (ADS)

    Hosoi, Haruko; Tayama, Ryo; Takeuchi, Satoshi; Tahara, Tahei

    2015-06-01

    Two-photon absorption spectra of 4‧-hydroxybenzylidene-2,3-dimethylimidazolinone, a model chromophore of enhanced green fluorescent protein (eGFP), were measured in various solvents. The two-photon absorption band of its anionic form is markedly blue-shifted from the corresponding one-photon absorption band in all solvents. Moreover, the magnitude of the blue shift varies largely depending on the solvent, which does not accord with the assignment of the two-photon absorption band to the transitions to the vibrationally excited S1 state. Our finding is readily rationalized by considering overlapping contributions of the S1 ← S0 and S2 ← S0 transitions, suggesting the involvement of the S2 state also in two-photon fluorescence of eGFP.

  15. Metal furnace heated by flame as a hydride atomizer for atomic absorption spectrometry: Sb determination in environmental and pharmaceutical samples.

    PubMed

    Figueiredo, Eduardo Costa; Dĕdina, Jirí; Arruda, Marco Aurélio Zezzi

    2007-10-15

    The present work describes a metallic hydride atomizer for atomic absorption spectrometry, by evaluating the performance of the Inconel 600((R)) tube. For this purpose, stibine was used as the model volatile compound and antimony determination in river and lake sediments and in pharmaceutical samples was carried out to assess the metal furnace performance. Some parameters are evaluated such as those referring to the generation and transport of the hydride (such as KBH(4) and acid concentrations, carrier gas flow rate, injected volume, etc.), as well as those referring to the metal furnace (such as tube hole area, flame composition, long-term stability, etc.). The method presents linear Sb concentration from 2 to 80mugL(-1) range (r>0.998; n=3) and the analytical frequency of ca. 140h(-1). The limit of detection (LOD) is 0.23mugL(-1) and the precision, expressed as R.S.D., is less than 5% (40mugL(-1); n=10). The accuracy is evaluated through the reference materials, and the results are similar at 95% confidence level according to the t-test.

  16. Electronically excited dipole moment of 4-aminobenzonitrile from thermochromic absorption and fluorescence measurements

    NASA Astrophysics Data System (ADS)

    Kawski, A.; Kukliński, B.; Bojarski, P.

    2006-07-01

    The effect of temperature on absorption and fluorescence spectra of 4-aminobenzonitrile (ABN) in 1,2-dichloroethane is studied for temperature ranging from 296 K to 343 K. The analysis of absorption and fluorescence band shift on the basis of Bilot and Kawski theory [L. Bilot, A. Kawski, Z. Naturforsch. 17a (1962) 621], for the known dipole moment in the ground state μg = 5.92 D, and α/ a3 = 0.5 ( α is the polarizability and a is the Onsager interaction radius of the solute) yields for ABN: (1) the empirical Onsager interaction radius a = 3.3 Å, (2) the dipole moment in the excited S 1 state μe = 7.14 D which agrees very well with the value of μe = 7.20 D obtained by Borst et al. [D.R. Borst, T.M. Korter, D.W. Pratt, Chem. Phys. Lett. 350 (2001) 485] from Stark effect studies. Both values of μe concern free ABN molecule and differ significantly from the values of μg (8.0 D, 8.5 D and 8.3 D in cyclohexane, benzene and 1,4-dioxane, respectively) obtained by Schuddeboom et al. [W. Schuddeboom, S.A. Jonker, J.M. Warman, U. Leinhos, W. Kühnle, K.A. Zachariasse, J. Phys. Chem. 96 (1992) 10809] from the time-resolved microwave conductivity measurements which are solvent-dependent. The group moment additivity law in the case of ABN molecule is approximately applicable, both in the ground and in the excited electronic state.

  17. Absorption spectroscopy of heavy alkaline earth metals Ba and Sr in rare gas matrices—CCSD(T) calculations and atomic site occupancies

    SciTech Connect

    Davis, Barry M.; McCaffrey, John G.

    2016-01-28

    Isolation of the heavier alkaline earth metals Ba and Sr in the solid rare gases (RGs) Ar, Kr, and Xe is analysed with absorption spectroscopy and interpreted partly with the assistance of ab initio calculations of the diatomic M ⋅ RG ground state interaction potentials. The y{sup 1}P←a{sup 1}S resonance transitions in the visible spectral region are used to compare the isolation conditions of these two metal atom systems and calcium. Complex absorption bands were recorded in all three metal atom systems even after extensive sample annealing. Coupled cluster calculations conducted on the ground states of the nine M ⋅ RG diatomics (M = Ca, Sr, and Ba; RG = Ar, Kr, and Xe) at the coupled cluster single, double, and non-iterative triple level of theory revealed long bond lengths (>5 Å) and shallow bound regions (<130 cm{sup −1}). All of the M ⋅ RG diatomics have bond lengths considerably longer than those of the rare gas dimers, with the consequence that isolation of these metal atoms in a single substitutional site of the solid rare gas is unlikely, with the possible exception of Ca/Xe. The luminescence of metal dimer bands has been recorded for Ba and Sr revealing very different behaviours. Resonance fluorescence with a lifetime of 15 ns is observed for the lowest energy transition of Sr{sub 2} while this transition is quenched in Ba{sub 2}. This behaviour is consistent with the absence of vibrational structure on the dimer absorption band in Ba{sub 2} indicating lifetime broadening arising from efficient relaxation to low-lying molecular states. More extensive 2D excitation-emission data recorded for the complex site structures present on the absorption bands of the atomic Ba and Sr systems will be presented in future publications.

  18. Absorption spectroscopy of heavy alkaline earth metals Ba and Sr in rare gas matrices--CCSD(T) calculations and atomic site occupancies.

    PubMed

    Davis, Barry M; McCaffrey, John G

    2016-01-28

    Isolation of the heavier alkaline earth metals Ba and Sr in the solid rare gases (RGs) Ar, Kr, and Xe is analysed with absorption spectroscopy and interpreted partly with the assistance of ab initio calculations of the diatomic M ⋅ RG ground state interaction potentials. The y(1)P ← a(1)S resonance transitions in the visible spectral region are used to compare the isolation conditions of these two metal atom systems and calcium. Complex absorption bands were recorded in all three metal atom systems even after extensive sample annealing. Coupled cluster calculations conducted on the ground states of the nine M ⋅ RG diatomics (M = Ca, Sr, and Ba; RG = Ar, Kr, and Xe) at the coupled cluster single, double, and non-iterative triple level of theory revealed long bond lengths (>5 Å) and shallow bound regions (<130 cm(-1)). All of the M ⋅ RG diatomics have bond lengths considerably longer than those of the rare gas dimers, with the consequence that isolation of these metal atoms in a single substitutional site of the solid rare gas is unlikely, with the possible exception of Ca/Xe. The luminescence of metal dimer bands has been recorded for Ba and Sr revealing very different behaviours. Resonance fluorescence with a lifetime of 15 ns is observed for the lowest energy transition of Sr2 while this transition is quenched in Ba2. This behaviour is consistent with the absence of vibrational structure on the dimer absorption band in Ba2 indicating lifetime broadening arising from efficient relaxation to low-lying molecular states. More extensive 2D excitation-emission data recorded for the complex site structures present on the absorption bands of the atomic Ba and Sr systems will be presented in future publications.

  19. Ablation-initiated Isotope-selective Atomic Absorption Spectroscopy of Lanthanide Elements

    SciTech Connect

    Miyabe, M.; Oba, M.; Iimura, H.; Akaoka, K.; Maruyama, Y.; Wakaida, I.; Watanabe, K.

    2009-03-17

    For remote isotope analysis of low-decontaminated trans-uranium (TRU) fuel, absorption spectroscopy has been applied to a laser-ablated plume of lanthanide elements. To improve isotopic selectivity and detection sensitivity of the ablated species, various experimental conditions were optimized. Isotope-selective absorption spectra were measured by observing the slow component of the plume produced under low-pressure rare-gas ambient. The measured minimum line width of about 0.9 GHz was close to the Doppler width of the Gd atomic transition at room temperature. The relaxation rate of high-lying metastable state was found to be higher than that of the ground state, which suggests that higher analytical sensitivity can be obtained using low-lying state transition. Under helium gas environment, Doppler splitting was caused from particle motion. This effect was considered for optimization for isotope selection and analysis. Some analytical performances of this method were determined under optimum conditions and were discussed.

  20. Possible atomic structures responsible for the sub-bandgap absorption of chalcogen-hyperdoped silicon

    SciTech Connect

    Wang, Ke-Fan; Shao, Hezhu; Liu, Kong; Qu, Shengchun E-mail: wangyx@henu.edu.cn; Wang, Zhanguo; Wang, Yuanxu E-mail: wangyx@henu.edu.cn

    2015-09-14

    Single-crystal silicon was hyperdoped with sulfur, selenium, and tellurium using ion implantation and nanosecond laser melting. The hyperdoping of such chalcogen elements led to strong and wide sub-bandgap light absorption. Annealing the hyperdoped silicon, even at low temperatures (such as 200–400 °C), led to attenuation of the sub-bandgap absorption. To explain the attenuation process, we modeled it as chemical decomposition reaction from an optically absorbing structure to a non-absorbing structure. Attenuation of the experimental absorption coefficient was fit using the Arrhenius equation. From the fitted data, we extracted the reaction activation energies of S-, Se-, and T-hyperdoped silicon as 0.338 ± 0.029 eV, 0.471 ± 0.040 eV, and 0.357 ± 0.028 eV, respectively. We discuss these activation energies in terms of the bond energies of chalcogen–Si metastable bonds, and suggest that several high-energy interstitial sites, rather than substitutional sites, are candidates for the atomic structures that are responsible for the strong sub-bandgap absorption of chalcogen hyperdoped silicon.

  1. Application of thermospray flame furnace atomic absorption spectrometry for investigation of silver nanoparticles.

    PubMed

    Sirirat, Natnicha; Tetbuntad, Kornrawee; Siripinyanond, Atitaya

    2017-03-01

    Thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was applied to investigate the time-dependent absorption peak profile of various forms of silver. The thermospray flame furnace was set up with a 10-cm-long nickel tube with six holes, each 2.0 mm in diameter, to allow the flame to enter, and this nickel tube acted as a furnace. A sample of 300 μL was introduced into this furnace by use of water as a carrier at a flow rate of 0.5 mL min(-1) through the ceramic capillary (0.5-mm inner diameter and 2.0-mm outer diameter), which was inserted into the front hole of the nickel tube. The system was applied to examine atomization behaviors of silver nanoparticles (AgNPs) with particle sizes ranging from 10 to 100 nm. The atomization rate of AgNPs was faster than that of the dissolved silver ion. With increased amount of silver, the decay time observed from the time-dependent absorption peak profile was shortened in the case of dissolved silver ion, but it was increased in the case of AgNPs. With the particle size ranging from 10 to 100 nm, the detection sensitivity was indirectly proportional to the particle size, suggesting that TS-FF-AAS may offer insights into the particle size of AgNPs provided that the concentration of the silver is known. To obtain quantitative information on AgNPs, acid dissolution of the particles was performed before TS-FF-AAS analysis, and recoveries of 80-110% were obtained.

  2. Heavy Metals Effect on Cyanobacteria Synechocystis aquatilis Study Using Absorption, Fluorescence, Flow Cytometry, and Photothermal Measurements

    NASA Astrophysics Data System (ADS)

    Dudkowiak, A.; Olejarz, B.; Łukasiewicz, J.; Banaszek, J.; Sikora, J.; Wiktorowicz, K.

    2011-04-01

    The toxic effect of six heavy metals on cyanobacteria Synechocystis aquatilis was studied by absorption, fluorescence, flow cytometry, and photothermal measurements. This study indicates that at the concentration used, the cyanobacteria are more sensitive to silver, copper, and mercury than to cadmium, lead, and zinc metals. Disregarding the decrease in the yields of the related radiative processes caused by photochemical processes and/or damage to phycobilisomes, no changes were detected in the efficiency of thermal deactivation processes within a few microseconds, which can indicate the lack of disturbances in the photosynthetic light reaction and the lack of damage to the photosystem caused by the heavy metal ions in the concentrations used. The results demonstrate that the relative values of fluorescence yield as well as promptly generated heat calculated for the metal-affected and unaffected (reference) bacteria are sensitive indicators of environmental pollution with heavy metal ions, whereas the complementary methods proposed could be used as a noninvasive and fast procedure for in vivo assessment of their toxicity.

  3. Analysis of lithium in deep basalt groundwaters using graphite furnace atomic absorption spectrophotometry

    SciTech Connect

    Dill, J.A.; Marcy, A.D.

    1986-05-01

    Lithium is under consideration for use as a reactive (sorptive) tracer in experiments designed to provide information regarding natural attenuation processes in a basalt-groundwater environment. In support of these activities, background lithium concentrations in samples obtained from a variety of test horizons have been determined using graphite furnace atomic absorption spectrophotometry. Significant interference was observed in these determinations and was found to be due to the presence of silicate in the samples. It was found that these problems could be circumvented through the use of alkaline silicate or synthetic groundwater matrix modifiers. This matrix effect was examined in some detail. Results obtained using the graphite furnace were compared to results obtained using inductively coupled plasma atomic emission spectroscopy.

  4. [Determination of trace selenium in edible fungi with graphite furnace atomic absorption spectroscopy].

    PubMed

    Tie, Mei; Zhang, Wei; Li, Jing; Jing, Kui; Zang, Shu-liang; Li, Hua-wei

    2006-01-01

    In the present article, samples were digested by a quartz high-pressure digestion pot, reducing the loss of selenium in digestion. The content of selenium in edible fungi was determined by using graphite furnace atomic absorption spectroscopy, and the results showed that when the content of selenium in edible fungi was determined by using 1% Ni(NO3)2 as a matrix modifier, ashing temperature of 500 degreed C, and atomization temperature of 2 500 degrees C, and rectifying background by deuterium light, the recovery was in the range of 92.1%-115.5%, the relative standard deviation of the method was 1.28%, and the limit of detection was 15.8 microg x L(-1). The method was suitable for the determination of trace selenium in edible fungi with the advantages of being simple, rapid, sensitive, stable and accurate etc., and the results were satisfactory.

  5. Determination of ruthenium in pharmaceutical compounds by graphite furnace atomic absorption spectroscopy.

    PubMed

    Jia, Xiujuan; Wang, Tiebang; Bu, Xiaodong; Tu, Qiang; Spencer, Sandra

    2006-04-11

    A graphite furnace atomic absorption (GFAA) spectrometric method for the determination of ruthenium (Rh) in solid and liquid pharmaceutical compounds has been developed. Samples are dissolved or diluted in dimethyl sulfoxide (DMSO) without any other treatment before they were analyzed by GFAA with a carefully designed heating program to avoid pre-atomization signal loss and to achieve suitable sensitivity. Various inorganic and organic solvents were tested and compared and DMSO was found to be the most suitable. In addition, ruthenium was found to be stable in DMSO for at least 5 days. Spike recoveries ranged from 81 to 100% and the limit of quantitation (LOQ) was determined to be 0.5 microg g(-1) for solid samples or 0.005 microg ml(-1) for liquid samples based a 100-fold dilution. The same set of samples was also analyzed by ICP-MS with a different sample preparation method, and excellent agreement was achieved.

  6. Determination of tellurium in geochemical materials by flameless atomic-absorption spectroscopy.

    PubMed

    Sighinolfi, G P; Santos, A M; Martinelli, G

    1979-02-01

    A method is described for the determination of tellurium at nanogram levels in rocks and in other complex materials by the use of flameless atomic-absorption spectroscopy. A very selective organic extraction procedure is applied to avoid matrix interference effects during extraction of Te and the atomization stage in the graphite furnace. Prior separation of iron and other interfering elements is achieved by a combined cupferron-ethyl acetate extraction. Tellerium is extracted from 6M hydrochloric acid with MIBK and stripped into aqueous medium. Pipetting of the aqueous extract into the graphite furnace gives fairly good instrumental reproducibility (2-3% error). Detection limits of about 10 ppM Te for a 0.5-g sample have been achieved with the medium-performance apparatus used. Results for Te in some geochemical reference materials are reported. Indications are given for the determination of Sb and Mo in the same solutions.

  7. Determination of traces of silver in waters by anion exchange and atomic absorption spectrophotometry

    USGS Publications Warehouse

    Chao, T.T.; Fishman, M. J.; Ball, J.W.

    1969-01-01

    A method has been developed for the accurate determination of 0.1-1 ??g of silver per liter of water. The method permits stabilization of silver in water without loss to container walls. Optimum conditions have been established for the complete recovery of silver from water with an anion-exchange column, for quantitative elution of silver from the resin, and for measurement of silver by atomic absorption spectrophotometry after chelation with ammonium pyrrolidine dithiocarbamate and extraction of the chelate with MIBK. Silver in the 1-10 ??g 1 range can be determined by extraction without pre-concentration on an ion-exchange resin. ?? 1969.

  8. Determination of heavy metals in solid emission and immission samples using atomic absorption spectroscopy

    SciTech Connect

    Fara, M.; Novak, F.

    1995-12-01

    Both flame and electrothermal methods of atomic absorption spectroscopy (AAS) have been applied to the determination of Al, As, Be, Ca, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, TI, Se, V and Zn in emission and emission (deposition) samples decomposed in open PTFE test-tubes by individual fuming-off hydrofluoric, perchloroic and nitric acid. An alternative hydride technique was also used for As and Se determination and Hg was determined using a self-contained AAS analyzer. A graphite platform proved good to overcome non-spectral interferences in AAS-ETA. Methods developed were verified by reference materials (inc. NBS 1633a).

  9. Automated atomic absorption spectrometric determination of total arsenic in water and streambed materials

    USGS Publications Warehouse

    Fishman, M.

    1977-01-01

    An automated method to determine both inorganic and organic forms of arsenic In water, water-suspended mixtures, and streambed materials Is described. Organic arsenic-containing compounds are decomposed by either ultraviolet radiation or by suHurlc acid-potassium persulfate digestion. The arsenic liberated, with Inorganic arsenic originally present, is reduced to arsine with sodium borohydrlde. The arable Is stripped from the solution with the aid of nitrogen and Is then decomposed In a tube furnace heated to 800 ??C which Is placed in the optical path of an atomic absorption spectrometer. Thirty samples per hour can be analyzed to levels of 1 ??g arsenic per liter.

  10. The determination of aluminum, copper, iron, and lead in glycol formulations by atomic absorption spectroscopy

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Initial screening tests and the results obtained in developing procedures to determine Al, Cu, Fe, and Pb in glycol formulations are described. Atomic absorption completion was selected for Cu, Fe and Pb, and after comparison with emission spectroscopy, was selected for Al also. Before completion, carbon, iron, and lead are extracted with diethyl dithio carbamate (DDC) into methyl isobutyl ketone (MIBK). Aluminum was also extracted into MIBK using 8-hydroxyquinoline as a chelating agent. As little as 0.02 mg/l carbon and 0.06 mg/l lead or iron may be determined in glycol formulations. As little as 0.3 mg/l aluminum may be determined.

  11. Refraction and absorption of x rays by laser-dressed atoms.

    SciTech Connect

    Buth, C.; Santra, R.; Young, L.

    2010-06-01

    X-ray refraction and absorption by neon atoms under the influence of an 800 nm laser with an intensity of 10{sup 13} W/cm{sup 2} is investigated. For this purpose, we use an ab initio theory suitable for optical strong-field problems. Its results are interpreted in terms of a three-level model. On the Ne 1s {yields} 3p resonance, we find electromagnetically induced transparency (EIT) for x rays. Our work opens novel perspectives for ultrafast x-ray pulse shaping.

  12. Neutral atomic absorption lines and far-UV extinction: Possible implications for depletions and grain parameters

    NASA Technical Reports Server (NTRS)

    Welty, Daniel E.

    1990-01-01

    Researchers examine nine lines of sight within the Galaxy and one in the Large Magellanic Cloud (LMC) for which data on both neutral atomic absorption lines (Snow 1984; White 1986; Welty, Hobbs, and York 1989) and far UV extinction (Bless and Savage 1972; Jenkins, Savage, and Spitzer 1986) are available, in order to test the assumption that variations in gamma/alpha will cancel in taking ratios of the ionization balance equation, and to try to determine to what extent that assumption has affected the aforementioned studies of depletions and grain properties.

  13. Neutral atomic absorption lines and far-UV extinction: Possible implications for depletions and grain parameters

    NASA Astrophysics Data System (ADS)

    Welty, Daniel E.

    1990-07-01

    Researchers examine nine lines of sight within the Galaxy and one in the Large Magellanic Cloud (LMC) for which data on both neutral atomic absorption lines (Snow 1984; White 1986; Welty, Hobbs, and York 1989) and far UV extinction (Bless and Savage 1972; Jenkins, Savage, and Spitzer 1986) are available, in order to test the assumption that variations in gamma/alpha will cancel in taking ratios of the ionization balance equation, and to try to determine to what extent that assumption has affected the aforementioned studies of depletions and grain properties.

  14. [Determination of calcium and magnesium in wheat flour by suspension sampling-flame atomic absorption spectrometry].

    PubMed

    Liu, L; Zhang, Q; Hu, Y

    1999-06-01

    Suspension sampling technique was applied to flame atomic absorption spectrometry and was successfully used to determine calcium and magnesium in wheat flour. The wheat flour was suspended in agar sol containing dibutyl phthalate and made into suspension. Choice of suspension agent and elimination of chemical interference were studied. The test solution was injected into air-acetylene flame to determine calcium and magnesium by standard addition method. Determination results were consistent with those obtained by ashing method. The t-test showed that no difference was found between the two methods. Displacement of ashing method by suspension sampling method for the sample pretreatment is possible. This method is convenient, rapid and accurate.

  15. Determination of beryllium in urine by graphite furnace atomic absorption spectrophotometry

    SciTech Connect

    Thorat, D.D.; Bhat, P.N.; Mahadevan, T.N.

    1995-08-01

    A method for the determination of beryllium in urine samples by Graphite Furnace Atomic Absorption Spectrophotometry (GFAAS) has been developed. The background correction problem due to the sample matrix was overcome by solvent extraction step. Urine samples were digested with a mixture of concentrated nitric and sulphuric acids. Beryllium in solution was complexed with acetylacetone, extracted in chloroform at pH 8.5 and back extracted in 2%(v/v) nitric acid for final analysis by AAS. The range of concentrations of beryllium observed in urine samples covering both occupational and control subject was 0.03 - 0.37 ng Be/ml.

  16. Determination of mercury in sewage sludge by direct slurry sampling graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Baralkiewicz, Danuta; Gramowska, Hanka; Kózka, Małgorzata; Kanecka, Anetta

    2005-03-01

    Ultrasonic slurry sampling electrothermal atomic absorption spectrometry (ETAAS) method was elaborated to the determination of Hg in sewage sludge samples with the use of KMnO 4+Pd modifier. The minimum sample amount required for slurry preparation with respect to sample homogeneity was evaluated by weighting masses between 3 and 30 mg directly into the autosampler cups. Validation of the proposed method was performed with the use of Certified Reference Materials of sewage sludge, CRM 007-040 and CRM 144R. Two sewage sludge samples from Poznañ (Poland) city were analysed using the present direct method and a method with sample digestion, resulting in no difference within statistical error.

  17. Iron analysis in atmospheric water samples by atomic absorption spectroscopy (AAS) in water-methanol.

    PubMed

    Sofikitis, A M; Colin, J L; Desboeufs, K V; Losno, R

    2004-01-01

    To distinguish between Fe(II) and Fe(III) species in atmospheric water samples, we have adapted an analytical procedure based on the formation of a specific complex between Fe(II) and ferrozine (FZ) on a chromatographic column. After elution of Fe(III), the Fe(II) complex is recovered with water-methanol (4:1). The possibility of trace iron measurements in this complex medium by graphite-furnace atomic-absorption spectrometry has been investigated. A simplex optimization routine was required to complete the development of the analytical method.

  18. [Electrothermal atomic absorption determination of arsenic in plants and plant products].

    PubMed

    Karpova, E A; Malysheva, A G; Ermakov, A A; Sidorenkova, N K

    2012-01-01

    The authors have developed the optimal temperature-time parameters of electrothermal atomic absorption determination of arsenic in plants after their acid predigestion. The matrix modifier is 1% nickel nitrate or palladium nitrate solution. Cuvettes (ovens) are simple, made of porous or pyrolytic graphite. The analytical program is suitable for both spectrometers with Zeeman and deuterium background correction. The correctness of the procedure has been estimated from the results of analysis of state reference samples certified for their arsenic content. The coefficient of variation was 20-35% for the concentration range of 0.02-0.2 mg/kg.

  19. Diode laser atomic fluorescence temperature measurements in low-pressure flames

    NASA Astrophysics Data System (ADS)

    Burns, I. S.; Lamoureux, N.; Kaminski, C. F.; Hult, J.; Desgroux, P.

    2008-12-01

    Temperature measurements have been performed in a low-pressure flame by the technique of diode laser induced atomic fluorescence. The experiments were done in a near-stoichiometric flat-flame of premixed methane, oxygen and nitrogen, at a pressure of 5.3 kPa. Indium atoms were seeded to the flame and probed using blue diode lasers; the lineshapes of the resulting fluorescence spectra were used to determine the flame temperature at a range of heights above the burner plate. The particular issues associated with the implementation of this measurement approach at low pressure are discussed, and it is shown to work especially well under these conditions. The atomic fluorescence lineshape thermometry technique is quicker to perform and requires less elaborate equipment than other methods that have previously been implemented in low-pressure flames, including OH-LIF and NO-LIF. There was sufficient indium present to perform measurements at all locations in the flame, including in the pre-heat zone close to the burner plate. Two sets of temperature measurements have been independently performed by using two different diode lasers to probe two separate transitions in atomic indium. The good agreement between the two sets of data provides a validation of the technique. By comparing thermocouple profiles recorded with and without seeding of the flame, we demonstrate that any influence of seeding on the flame temperature is negligible. The overall uncertainty of the measurements reported here is estimated to be ±2.5% in the burnt gas region.

  20. Method for the determination of cobalt from biological products with graphite furnace atomic absorption spectrometer

    NASA Astrophysics Data System (ADS)

    Zamfir, Oana-Liliana; Ionicǎ, Mihai; Caragea, Genica; Radu, Simona; Vlǎdescu, Marian

    2016-12-01

    Cobalt is a chemical element with symbol Co and atomic number 27 and atomic weight 58.93. 59 Co is the only stable cobalt isotope and the only isotope to exist naturally on Earth. Cobalt is the active center of coenzymes called cobalamin or cyanocobalamin the most common example of which is vitamin B12. Vitamin B12 deficiency can potentially cause severe and irreversible damage, especially to the brain and nervous system in the form of fatigue, depression and poor memory or even mania and psychosis. In order to study the degree of deficiency of the population with Co or the correctness of treatment with vitamin B12, a modern optoelectronic method for the determination of metals and metalloids from biological samples has been developed, Graphite Furnace - Atomic Absorption Spectrometer (GF- AAS) method is recommended. The technique is based on the fact that free atoms will absorb light at wavelengths characteristic of the element of interest. Free atoms of the chemical element can be produced from samples by the application of high temperatures. The system GF-AAS Varian used as biological samples, blood or urine that followed the digest of the organic matrix. For the investigations was used a high - performance GF-AAS with D2 - background correction system and a transversely heated graphite atomizer. As result of the use of the method are presented the concentration of Co in the blood or urine of a group of patient in Bucharest. The method is sensitive, reproducible relatively easy to apply, with a moderately costs.

  1. Determination of Copper by Graphite Furnace Atomic Absorption Spectrophotometry: A Student Exercise in Instrumental Methods of Analysis.

    ERIC Educational Resources Information Center

    Williamson, Mark A.

    1989-01-01

    Discusses a student exercise which requires the optimizing of the charring and atomization temperatures by producing a plot of absorbance versus temperature for each temperature parameter. Notes that although the graphite furnace atomic absorption spectroscopy technique has widespread industrial use, there are no published, structured experiments…

  2. The effects of pH and surfactants on the absorption and fluorescence properties of ochratoxin A and zearalenone.

    PubMed

    Li, Taihua; Kim, Bo Bae; Ha, Tae Hwan; Shin, Yong-Beom; Kim, Min-Gon

    2015-11-01

    The pH and surfactant dependencies of the absorption and fluorescence properties of ochratoxin A (OTA) and zearalenone (ZEN), the main mycotoxins found as contaminants in foods and feeds, were evaluated. Three surfactants with different ionic properties were investigated, namely sodium dodecyl sulfate (SDS, anionic), Tween 20 (nonionic) and hexadecyltrimethylammonium bromide (CTAB, cationic). The results show that the effects of pH on the absorption wavelength maxima and fluorescence efficiencies of the mycotoxins, which are a consequence of the presence of acidic phenol and/or carboxyl containing fluorophores, are dependent on the ionic nature of the added surfactants. Specifically, the fluorescence responses to pH changes of OTA and ZEN are similar in the presence or absence of Tween 20 and SDS. By contrast, the pH-dependent fluorescence properties of these mycotoxins are altered when CTAB is present in the solutions. Moreover, unlike OTA, ZEN in aqueous solution displays almost no fluorescence. However, fluorescence enhancement takes place when surfactants are present in aqueous solutions of this mycotoxin. The results of this study demonstrate that the different microenvironments, present in the organized micellar systems created by the individual surfactants, can be potentially employed to modulate the sensitivities and selectivities of the fluorescence detection of OTA or ZEN.

  3. Sizeable red-shift of absorption and fluorescence of subporphyrazine induced by peripheral push and pull substitution.

    PubMed

    Liang, Xu; Shimizu, Soji; Kobayashi, Nagao

    2014-11-18

    Peripheral substitution with electron-donating (push) and electron-withdrawing (pull) substituents caused a sizeable red-shift of the Q band absorption and fluorescence of subporphyrazine, and the red-shift was controlled by the push substituents. Control of the chromophore symmetry and inherent molecular chirality arising from the pattern of substitution were also investigated.

  4. Measurement of urinary mercury excretion by atomic absorption in health and disease

    PubMed Central

    Taylor, Andrew; Marks, Vincent

    1973-01-01

    Taylor, A., and Marks, V. (1973).British Journal of Industrial Medicine,30, 293-296. Measurement of urinary excretion by atomic absorption in health and disease. Excretion of mercury was measured by a cold-vapour atomic absorption technique on samples of urine from five groups of people having varying exposure to mercury. Serial investigations of up to 14 days were carried out on eight subjects to determine the temporal relationship between exposure and excretion. Subjects with no exposure excreted 0-10 μg mercury per gramme creatinine. Similar values were found in laboratory staff and men assembling hollow cathode lamps. Excretion of mercury by dental workers was significantly increased. No correlation between exposure and excretion of mercury was seen in the subjects investigated. The significance of measuring urinary excretion in the detection of mercury intoxication is discussed. The suggestion is made that urinary mercury excretion of more than 20 μg/g creatinine or 40 μg mercury per 24 hours should be considered evidence of recent or remote exposure to mercury. It is concluded that measurement of urinary mercury excretion is important in revealing those persons who may ultimately develop symptoms of toxicity. PMID:4723792

  5. Polarisation response of delay dependent absorption modulation in strong field dressed helium atoms probed near threshold

    NASA Astrophysics Data System (ADS)

    Simpson, E. R.; Sanchez-Gonzalez, A.; Austin, D. R.; Diveki, Z.; Hutchinson, S. E. E.; Siegel, T.; Ruberti, M.; Averbukh, V.; Miseikis, L.; Strüber, C. S.; Chipperfield, L.; Marangos, J. P.

    2016-08-01

    We present the first measurement of the vectorial response of strongly dressed helium atoms probed by an attosecond pulse train (APT) polarised either parallel or perpendicular to the dressing field polarisation. The transient absorption is probed as a function of delay between the APT and the linearly polarised 800 nm field of peak intensity 1.3× {10}14 {{W}} {{cm}}-2. The APT spans the photon energy range 16-42 eV, covering the first ionisation energy of helium (24.59 eV). With parallel polarised dressing and probing fields, we observe modulations with periods of one half and one quarter of the dressing field period. When the polarisation of the dressing field is altered from parallel to perpendicular with respect to the APT polarisation we observe a large suppression in the modulation depth of the above ionisation threshold absorption. In addition to this we present the intensity dependence of the harmonic modulation depth as a function of delay between the dressing and probe fields, with dressing field peak intensities ranging from 2 × 1012 to 2 × 1014 {{W}} {{cm}}-2. We compare our experimental results with a full-dimensional solution of the single-atom time-dependent (TD) Schrödinger equation obtained using the recently developed abinitio TD B-spline ADC method and find good qualitative agreement for the above threshold harmonics.

  6. Determination of sodium and potassium in nanoliter volumes of biological fluids by furnace atomic absorption spectrometry

    SciTech Connect

    Nash, L.A.; Peterson, L.N.; Nadler, S.P.; Levine, D.Z.

    1988-11-01

    Renal tubular fluid samples are nanoliter (10/sup -9/ L) volumes containing sodium and potassium concentrations that are within the range of determination by furnace atomic absorption. Modification of nanoliter handling techniques and the use of microboats with the IL 951/655 provided a method for rapid precise analyses (relative standard deviation of 5%). Determinations of sodium and potassium were precise; however, inaccuracies occurred with anion substitution of sodium salts. NaHCO/sub 3/ solutions gave consistently higher peak height absorbance and area absorbance compared with those of NaCl: the peak area absorbance correlated linearly with the concentration of bicarbonate. Pretreatment of the microboat with boric acid eliminated this phenomenon and the associated inaccuracy. Comparison of determination of sodium in nanoliter samples by graphite furnace atomic absorption with macroanalysis by flame emission gave relative errors of less than 2.0%. Addition of sodium and potassium to tubular fluid samples yielded mean recoveries of 102.6% and 99.7%, respectively. The authors conclude that graphite furnace can be an accurate method for measurement of sodium and potassium in nanoliter volumes of biological fluids.

  7. Multi-element analysis of manganese nodules by atomic absorption spectrometry without chemical separation

    USGS Publications Warehouse

    Kane, J.S.; Harnly, J.M.

    1982-01-01

    Five manganese nodules, including the USGS reference nodules A-1 and P-1, were analyzed for Co, Cu, Fe, K, Mg, Mn, Na, Ni and Zn without prior chemical separation by using a simultaneous multi-element atomic absorption spectrometer with an air-cetylene flame. The nodules were prepared in three digestion matrices. One of these solutions was measured using sixteen different combinations of burner height and air/acetylene ratios. Results for A-1 and P-1 are compared to recommended values and results for all nodules are compared to those obtained with an inductively coupled plasma. The elements Co, Cu, Fe, K, Mg, Mn, Na, Ni, and Zn are simultaneously determined with a composite recovery for all elements of 100 ?? 7%, independent of the digestion matrices, heights in the flame, or flame stoichiometries examined. Individual recoveries for Co, K, and Ni are considerably poorer in two digests than this composite figure, however. The optimum individual recoveries of 100 ?? 5% and imprecisions of 1-4%, except for zinc, are obtained when Co, K, Mn, Na and Ni are determined simultaneously in a concentrated digest, and in another analytical sequence, when Cu, Fe, Mg, Mn and Zn are measured simultaneously after dilution. Determination of manganese is equally accurate in the two sequences; its measurement in both assures internal consistency between the two measurement sequences. This approach improves analytical efficiency over that for conventional atomic absorption methods, while minimizing loss of accuracy or precision for individual elements. ?? 1982.

  8. Use of flameless atomic absorption spectroscopy in immune cytolysis for nonradioactive determination of killer cell activity.

    PubMed

    Borella, P; Bargellini, A; Salvioli, S; Cossarizza, A

    1996-02-01

    We describe here a novel method to evaluate natural killer (NK) cytolytic activity by use of flameless atomic absorption spectroscopy (GF-AAS). This technique may be adopted for use in laboratories equipped with electrothermal atomic absorption spectrometers. Nonradioactive Cr as Na2CrO4 was used to label target cells (K562), and cell lysis was evaluated by measuring Cr released after 4 h of incubation with the effectors. We selected 520 micrograms/L as the optimal dose for labeling targets, between 12 and 20 h as the optimal incubation time, and 10(4) cells as the optimal target size. Advantages of this method include: (a) exclusion of radioactive tracer, with no risk for workers; (b) limited costs; (c) high sensitivity and reproducibility; (d) possibility to store samples; and (e) better control of Cr used for labeling cells due to well-determined, fixed Cr concentrations in the range of nontoxic and linear cellular uptake. Comparison with data obtained by conventional 51Cr labeling of targets killed by the same effectors was excellent, yielding comparable results and corroborating the method.

  9. Quantitation of a novel metalloporphyrin drug in plasma by atomic absorption spectroscopy.

    PubMed

    Hoffman, K L; Feng, M R; Rossi, D T

    1999-03-01

    A bioanalytical method to quantify cobalt mesoporphyrin (CoMP), a novel therapeutic agent, in plasma has been developed and validated. The approach involves atomic absorption spectroscopy to determine total cobalt in a sample and a back-calculation of the amount of compound present. Endogenous plasma cobalt concentrations were small ( <0.2 ng/ml(-1) Co in rat plasma) in comparison to the quantitation limit (4.5 ng/ml(-1) Co). The inter-day imprecision of the method was 10.0% relative standard deviation (RSD) and the inter-day bias was +/- 8.0% relative error (RE) over a standard curve range of 4.5- 45.0 ng/ml(-1) Co. Because it quantifies total cobalt, the method cannot differentiate between parent drug and metabolites, but negligible metabolism allows reliable estimates of the actual parent drug concentration. A correlation study between the atomic absorption method and 14C-radiometry demonstrated excellent agreement (r = 0.9868, slope = 1.041 +/- 0.028, intercept = 223.7 +/- 190.0) and further substantiated the accuracy of the methods. Methodology was successfully applied to a pharmacokinetic study of CoMP in rat, with pharmacokinetic parameter estimation. The elimination half-lives, after intra-muscular and subcutaneous administration, were 7.7 and 8.8 days, respectively.

  10. Determination of metal concentration in fat supplements for swine nutrition by atomic absorption spectroscopy.

    PubMed

    Cocchi, Marina; Faeti, Valerio; Manfredini, Matteo; Manzini, Daniela; Marchetti, Andrea; Sighinolfi, Simona

    2005-01-01

    The presence of some essential and toxic metals in fat supplements for swine diet was investigated. Collected samples represented a relevant production of the Italian industry. In particular, some samples were enriched with antioxidants or waste cooking oils. The method for the determination of Ca, Cu, Cd, Fe, Mg, Mn, Ni, Pb, and Zn in fat samples was developed by means of a certified reference material (CRM 186) and a representative fatty sample (RFS). All samples were digested in closed vessels in a microwave oven and then analyzed by flame atomic absorption or graphite furnace atomic absorption spectrometry. The entire analytical method provided a satisfactory repeatability and reproducibility confirmed by agreement between the experimental recovery data obtained for the CRM 186 sample and, with the method of standard additions, for the RFS material. The samples generally showed a small amount of metals compared with the recommended daily intake for the essential elements. On the other hand, some samples contained a significant concentration, from an analytical point of view, of Cd, Ni, and Pb. Principal component analysis (PCA) was applied to inspect the experimental data obtained from samples analysis. Basically no differences were detected in terms of metal concentration among the fat supplements analyzed.

  11. [The application of atomic absorption spectrometry in automatic transmission fault detection].

    PubMed

    Chen, Li-dan; Chen, Kai-kao

    2012-01-01

    The authors studied the innovative applications of atomic absorption spectrometry in the automatic transmission fault detection. After the authors have determined Fe, Cu and Cr contents in the five groups of Audi A6 main metal in automatic transmission fluid whose travel course is respectively 10-15 thousand kilometers, 20-26 thousand kilometers, 32-38 thousand kilometers, 43-49 thousand kilometers, and 52-58 thousand kilometers by atomic absorption spectrometry, the authors founded the database of primary metal content in the Audi A6 different mileage automatic transmission fluid (ATF). The research discovered that the main metal content in the automatic transmission fluid increased with the vehicles mileage and its normal metal content level in the automatic transmission fluid is between the two trend lines. The authors determined the main metal content of automatic transmission fluid which had faulty symptoms and compared it with its database value. Those can not only judge the wear condition of the automatic transmission which had faulty symptoms but also help the automobile detection and maintenance personnel to diagnose automatic transmission failure reasons without disintegration. This reduced automobile maintenance costs, and improved the quality of automobile maintenance.

  12. Shock-tube measurements of excited oxygen atoms using cavity-enhanced absorption spectroscopy.

    PubMed

    Nations, Marcel; Wang, Shengkai; Goldenstein, Christopher S; Sun, Kai; Davidson, David F; Jeffries, Jay B; Hanson, Ronald K

    2015-10-10

    We report the use of cavity-enhanced absorption spectroscopy (CEAS) using two distributed feedback diode lasers near 777.2 and 844.6 nm for sensitive, time-resolved, in situ measurements of excited-state populations of atomic oxygen in a shock tube. Here, a 1% O2/Ar mixture was shock-heated to 5400-8000 K behind reflected shock waves. The combined use of a low-finesse cavity, fast wavelength scanning of the lasers, and an off-axis alignment enabled measurements with 10 μs time response and low cavity noise. The CEAS absorption gain factors of 104 and 142 for the P35←S520 (777.2 nm) and P0,1,23←S310 (844.6 nm) atomic oxygen transitions, respectively, significantly improved the detection sensitivity over conventional single-pass measurements. This work demonstrates the potential of using CEAS to improve shock-tube studies of nonequilibrium electronic-excitation processes at high temperatures.

  13. Atomic oxygen adsorption and absorption on Rh(111) and Ag(111)

    NASA Astrophysics Data System (ADS)

    Derouin, Jonathan D.

    A central question in the field of heterogeneous catalysis is how surface structure and subsurface species influence catalytic behavior. One key to answering that question is determining which surface structures and subsurface species are present under catalytically relevant conditions. This dissertation presents results of Auger electron spectroscopy, low energy electron diffraction, temperature programmed desorption, and scanning tunneling microscopy experiments on oxidized Rh(111) and Ag(111) crystals. Exposing Rh(111) to O2 produced a predominately (2 x 1) adlayer, but even after extended dosing, (2 x 2) domains were also present. Exposing Rh(111) to atomic oxygen yielded O coverages greater than 0.5 ML and (1 x 1) domains were observed to form along terrace step edges. However, (2 x 1) and (2 x 2) domains were still present. Atomic oxygen was used to oxidize Ag(111) in order to study the effect of sample temperature as well as oxygen flux and energy. When atomic oxygen was generated using a lower temperature thermal cracker, a variety of previously reported surface structures were observed. When O was generated using a higher filament temperature, the surface became highly corrugated, layers of Ag 2O appeared to form, and little subsurface oxygen was observed. To investigate the role of sample temperature, the Ag(111) sample was held at various temperatures while being exposed to atomic oxygen. For short doses, sample temperature had minimal effect on surface reconstruction. For longer doses, changes in sample temperature in the range of 490 K to 525 K had a substantial impact on surface reconstruction and subsurface oxygen absorption. Higher temperature dosing yielded the same surface structures which were observed after short doses. Lower temperature dosing with atomic oxygen resulted in subsurface oxygen formation and new structures which covered the surface. The results indicate the rich complexity of oxygen/transition metal interactions and illustrate how

  14. Rhodium as permanent modifier for atomization of lead from biological fluids using tungsten filament electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Zhou, Ying; Parsons, Patrick J.; Aldous, Kenneth M.; Brockman, Paul; Slavin, Walter

    2002-04-01

    Rhodium (Rh) was investigated as a permanent modifier for the atomization of Pb from biological fluids in W-filament atomic absorption spectrometry (AAS). Heating the W-filament with a Rh solution provided a protective coating for subsequent determinations of Pb in blood and urine matrices. The W-filament AAS instrumentation used was based on a prototype design that utilized self-reversal background correction scheme and peak area measurements. We found that Rh not only stabilized Pb during the pyrolysis step, but also facilitated the removal of carbonaceous residues during the cleaning step, requiring much less power than with phosphate modifier. Thus, the filament lifetime was greatly extended to over 300 firings. Periodic reconditioning with Rh was necessary every 30 firings or so. Conditioning the filament with Rh also permitted direct calibration using simple aqueous Pb standards. The method detection limit for blood Pb was approximately 1.5 μg dl -1, similar to that reported previously. Potential interferences from concomitants such as Na, K, Ca and Mg were evaluated. Accuracy was verified using lead reference materials from the National Institute of Standards and Technology and the New York State Department of Health. Blood lead results below 40 μg dl -1 were within ±1 μg dl -1 of certified values, and within ±10% above 40 μg dl -1; within-run precision was ±10% or better. Additional validation was reported using proficiency test materials and human blood specimens. All blood lead results were within the acceptable limits established by regulatory authorities in the US. When measuring Pb in urine, sensitivity was reduced and matrix-matched calibration became necessary. The method of detection limit was 27 μg l -1 for urine Pb. Urine lead results were also validated using an acceptable range comparable to that established for blood lead by US regulatory agencies.

  15. Photoacoustic-fluorescence in vitro flow cytometry for quantification of absorption, scattering and fluorescence properties of the cells

    NASA Astrophysics Data System (ADS)

    Nedosekin, D. A.; Sarimollaoglu, M.; Foster, S.; Galanzha, E. I.; Zharov, V. P.

    2013-03-01

    Fluorescence flow cytometry is a well-established analytical tool that provides quantification of multiple biological parameters of cells at molecular levels, including their functional states, morphology, composition, proliferation, and protein expression. However, only the fluorescence and scattering parameters of the cells or labels are available for detection. Cell pigmentation, presence of non-fluorescent dyes or nanoparticles cannot be reliably quantified. Herewith, we present a novel photoacoustic (PA) flow cytometry design for simple integration of absorbance measurements into schematics of conventional in vitro flow cytometers. The integrated system allow simultaneous measurements of light absorbance, scattering and of multicolor fluorescence from single cells in the flow at rates up to 2 m/s. We compared various combinations of excitation laser sources for multicolor detection, including simultaneous excitation of PA and fluorescence using a single 500 kHz pulsed nanosecond laser. Multichannel detection scheme allows simultaneous detection of up to 8 labels, including 4 fluorescent tags and 4 PA colors. In vitro PA-fluorescence flow cytometer was used for studies of nanoparticles uptake and for the analysis of cell line pigmentation, including genetically encoded melanin expression in breast cancer cell line. We demonstrate that this system can be used for direct nanotoxicity studies with simultaneous quantification of nanoparticles content and assessment of cell viability using a conventional fluorescent apoptosis assays.

  16. Application of the Kubelka-Munk correction for self-absorption of fluorescence emission in carmine lake paint layers.

    PubMed

    Clementi, Catia; Miliani, Costanza; Verri, Giovanni; Sotiropoulou, Sophia; Romani, Aldo; Brunetti, Brunetto G; Sgamellotti, A

    2009-12-01

    The variations of the fluorescence emission of carmine lake travelling through an absorbing and scattering medium, such as a paint layer, were investigated by ultraviolet (UV)-visible absorption, fluorescence spectroscopy, and imaging techniques. Samples of the lake were studied in dilute and saturated solutions, on a reference test panel and a real case study. Relevant spectral modifications have been observed as a function of the lake concentration mainly consisting of a fluorescence quenching, red shift of emission maxima, and deformation of emission band. The application of a correction factor based on the Kubelka-Munk model allowed fluorescence spectra obtained in solution and on painted samples of known composition to be compared and correlated, highlighting that the fluorescence of the lake within paint layers is affected by both self-absorption and aggregation phenomena. This approach has been successfully applied on a painting by G. Vasari for the noninvasive identification of carmine lake. The results reported here emphasize the necessity of taking physical phenomena into account in the interpretation of the fluorescence spectra for a proper and reliable characterization and identification of painting materials in works of art.

  17. Nonlinear reconstruction of absorption and fluorescence contrast from measured diffuse transmittance and reflectance of a compressed-breast-simulating phantom.

    PubMed

    Ziegler, Ronny; Nielsen, Tim; Koehler, Thomas; Grosenick, Dirk; Steinkellner, Oliver; Hagen, Axel; Macdonald, Rainer; Rinneberg, Herbert

    2009-08-20

    We report on the nonlinear reconstruction of local absorption and fluorescence contrast in tissuelike scattering media from measured time-domain diffuse reflectance and transmittance of laser as well as laser-excited fluorescence radiation. Measurements were taken at selected source-detector offsets using slablike diffusely scattering and fluorescent phantoms containing fluorescent heterogeneities. Such measurements simulate in vivo data that would be obtained employing a scanning, time-domain fluorescence mammograph, where the breast is gently compressed between two parallel glass plates, and source and detector optical fibers scan synchronously at various source-detector offsets, allowing the recording of laser and fluorescence mammograms. The diffusion equations modeling the propagation of the laser and fluorescence radiation were solved in frequency domain by the finite element method simultaneously for several modulation frequencies using Fourier transformation and preprocessed experimental data. To reconstruct the concentration of the fluorescent contrast agent, the Born approximation including higher-order reconstructed photon densities at the excitation wavelength was used. Axial resolution was determined that can be achieved by various detection schemes. We show that remission measurements increase the depth resolution significantly.

  18. Reduction of matrix interferences in furnace atomic absorption with the L'vov Platform

    USGS Publications Warehouse

    Kaiser, M.L.; Koirtyohann, S.R.; Hinderberger, E.J.; Taylor, H.E.

    1981-01-01

    Use of a modified L'vov Platform and ammonium phosphate as a matrix modifier greatly reduced matrix interferences in a commercial Massmann-type atomic absorption furnace. Platforms were readily fabricated from furnace tubes and, once positioned in the furnace, caused no inconvenience in operation. Two volatile elements (Pb, Cd), two of intermediate volatility (Co, Cr) and two which form stable oxides (Al, Sn) were tested in natural water and selected synthetic matrices. In every case for which there was a significant matrix effect during atomization from the tube wall, the platform and platform plus modifier gave improved performance. With lead, for example, an average ratio of 0.48 ?? 0.11 was found when the slope of the standard additions plot for six different natural water samples was compared to the slope of the standard working curve in dilute acid. The average slope ratio between the natural water matrices and the dilute acid matrix was 0.94 ?? 0.03 with the L'vov Platform and 0.96 ?? 0.03 with the platform and matrix modifier. In none of the cases studied did the use of the platform or platform plus modifier cause an interference problem where none existed while atomizing from the tube wall. An additional benefit of the platform was a factor of about two improvement in peak height precision. ?? 1981.

  19. Slurry sampling graphite furnace atomic absorption spectrometry: determination of trace metals in mineral coal.

    PubMed

    Silva, M M; Goreti, M; Vale, R; Caramão, E B

    1999-12-06

    A procedure for lead, cadmium and copper determination in coal samples based on slurry sampling using an atomic absorption spectrometer equipped with a transversely heated graphite tube atomizer is proposed. The slurries were prepared by weighing the samples directly into autosampler cups (5-30 mg) and adding a 1.5 ml aliquot of a diluent mixture of 5% v/v HNO(3), 0.05% Triton X-100 and 10% ethanol. The slurry was homogenized by manual stirring before measurement. Slurry homogenization using ultrasonic agitation was also investigated for comparison. The effect of particle size and the use of different diluent compositions on the slurry preparation were investigated. The temperature programmes were optimized on the basis of pyrolysis and atomization curves. Absorbance characteristics with and without the addition of a palladium-magnesium modifier were compared. The use of 0.05% m/v Pd and 0.03% m/v Mg was found satisfactory for stabilizing Cd and Pb. The calibration was performed with aqueous standards. In addition, a conventional acid digestion procedure was applied to verify the efficiency of the slurry sampling. Better recoveries of the analytes were obtained when the particle size was reduced to <37 mum. Several certified coal reference materials (BCR Nos. 40, 180, and 181) were analyzed, and good agreement was obtained between the results from the proposed slurry sampling method and the certificate values.

  20. Handling complex effects in slurry-sampling-electrothermal atomic absorption spectrometry by multivariate calibration.

    PubMed

    Felipe-Sotelo, M; Cal-Prieto, M J; Gómez-Carracedo, M P; Andrade, J M; Carlosena, A; Prada, D

    2006-07-07

    Analysis of solid samples by slurry-sampling-electrothermal atomic absorption spectrometry (SS-ETAAS) can imply spectral and chemical interferences caused by the large amount of concomitants introduced into the graphite furnace. Sometimes they cannot be solved using stabilized temperature platform furnace (STPF) conditions or typical approaches (previous sample ashing, use of chemical modifiers, etc.), which are time consuming and quite expensive. A new approach to handle interferences using multivariate calibrations (partial least squares, PLS, and artificial neural networks, ANN) is presented and exemplified with a real problem consisting on determining Sb in several solid matrices (soils, sediments and coal fly ash) as slurries by ETAAS. Experimental designs were implemented at different levels of Sb to develop the calibration matrix and assess which concomitants (seven ions were considered) modified the atomic signal mostly. They were Na+ and Ca2+ and they induced simultaneous displacement, depletion (enhancement) and broadening of the atomic peak. Here it is shown that these complex effects can be handled in a reliable, fast and cost-effective way to predict the concentration of Sb in slurry samples of several solid matrices. The method was validated predicting the concentrations of five certified reference materials (CRMs) and studying its robustness to current ETAAS problems. It is also shown that linear PLS can handle eventual non-linearities and that its results are comparable to more complex (non-linear) models, as those from ANNs.

  1. Real-time near-field terahertz imaging with atomic optical fluorescence

    NASA Astrophysics Data System (ADS)

    Wade, C. G.; Šibalić, N.; de Melo, N. R.; Kondo, J. M.; Adams, C. S.; Weatherill, K. J.

    2017-01-01

    Terahertz (THz) near-field imaging is a flourishing discipline, with applications from fundamental studies of beam propagation to the characterization of metamaterials and waveguides. Beating the diffraction limit typically involves rastering structures or detectors with length scale shorter than the radiation wavelength; in the THz domain this has been achieved using a number of techniques including scattering tips and apertures. Alternatively, mapping THz fields onto an optical wavelength and imaging the visible light removes the requirement for scanning a local probe, speeding up image collection times. Here, we report THz-to-optical conversion using a gas of highly excited Rydberg atoms. By collecting THz-induced optical fluorescence we demonstrate a real-time image of a THz standing wave and use well-known atomic properties to calibrate the THz field strength.

  2. Electrochemical hydride generation atomic fluorescence spectrometry for detection of tin in canned foods using polyaniline-modified lead cathode.

    PubMed

    Jiang, Xianjuan; Gan, Wuer; Wan, Lingzhong; Deng, Yun; Yang, Qinghua; He, Youzhao

    2010-12-15

    An electrochemical hydride generation system with polyaniline-modified lead cathode was developed for tin determination by coupling with atomic fluorescence spectrometry. The tin fluorescence signal intensity was improved evidently as the polyaniline membrane could facilitate the transformation process from atomic tin to the SnH(4) and prevent the aggradation of Sn atom on Pb electrode surface. The effects of experimental parameters and interferences have been studied. The limit of detection (LOD) was 1.5 ng mL(-1) (3σ) and the relative standard deviation (RSD) was 3.3% for 11 consecutive measurements of 50 ng mL(-1) Sn(IV) standard solution.

  3. Development and validation of spectrophotometric, atomic absorption and kinetic methods for determination of moxifloxacin hydrochloride.

    PubMed

    Abdellaziz, Lobna M; Hosny, Mervat M

    2011-01-01

    Three simple spectrophotometric and atomic absorption spectrometric methods are developed and validated for the determination of moxifloxacin HCl in pure form and in pharmaceutical formulations. Method (A) is a kinetic method based on the oxidation of moxifloxacin HCl by Fe(3+) ion in the presence of 1,10 o-phenanthroline (o-phen). Method (B) describes spectrophotometric procedures for determination of moxifloxacin HCl based on its ability to reduce Fe (III) to Fe (II), which was rapidly converted to the corresponding stable coloured complex after reacting with 2,2' bipyridyl (bipy). The formation of the tris-complex formed in both methods (A) and (B) were carefully studied and their absorbance were measured at 510 and 520 nm respectively. Method (C) is based on the formation of ion- pair associated between the drug and bismuth (III) tetraiodide in acidic medium to form orange-red ion-pair associates. This associate can be quantitatively determined by three different procedures. The formed precipitate is either filtered off, dissolved in acetone and quantified spectrophotometrically at 462 nm (Procedure 1), or decomposed by hydrochloric acid, and the bismuth content is determined by direct atomic absorption spectrometric (Procedure 2). Also the residual unreacted metal complex in the filtrate is determined through its metal content using indirect atomic absorption spectrometric technique (procedure 3). All the proposed methods were validated according to the International Conference on Harmonization (ICH) guidelines, the three proposed methods permit the determination of moxifloxacin HCl in the range of (0.8-6, 0.8-4) for methods A and B, (16-96, 16-96 and 16-72) for procedures 1-3 in method C. The limits of detection and quantitation were calculated, the precision of the methods were satisfactory; the values of relative standard deviations did not exceed 2%. The proposed methods were successfully applied to determine the drug in its pharmaceutical formulations

  4. Development and Validation of Spectrophotometric, Atomic Absorption and Kinetic Methods for Determination of Moxifloxacin Hydrochloride

    PubMed Central

    Abdellaziz, Lobna M.; Hosny, Mervat M.

    2011-01-01

    Three simple spectrophotometric and atomic absorption spectrometric methods are developed and validated for the determination of moxifloxacin HCl in pure form and in pharmaceutical formulations. Method (A) is a kinetic method based on the oxidation of moxifloxacin HCl by Fe3+ ion in the presence of 1,10 o-phenanthroline (o-phen). Method (B) describes spectrophotometric procedures for determination of moxifloxacin HCl based on its ability to reduce Fe (III) to Fe (II), which was rapidly converted to the corresponding stable coloured complex after reacting with 2,2′ bipyridyl (bipy). The formation of the tris-complex formed in both methods (A) and (B) were carefully studied and their absorbance were measured at 510 and 520 nm respectively. Method (C) is based on the formation of ion- pair associated between the drug and bismuth (III) tetraiodide in acidic medium to form orange—red ion-pair associates. This associate can be quantitatively determined by three different procedures. The formed precipitate is either filtered off, dissolved in acetone and quantified spectrophotometrically at 462 nm (Procedure 1), or decomposed by hydrochloric acid, and the bismuth content is determined by direct atomic absorption spectrometric (Procedure 2). Also the residual unreacted metal complex in the filtrate is determined through its metal content using indirect atomic absorption spectrometric technique (procedure 3). All the proposed methods were validated according to the International Conference on Harmonization (ICH) guidelines, the three proposed methods permit the determination of moxifloxacin HCl in the range of (0.8–6, 0.8–4) for methods A and B, (16–96, 16–96 and 16–72) for procedures 1–3 in method C. The limits of detection and quantitation were calculated, the precision of the methods were satisfactory; the values of relative standard deviations did not exceed 2%. The proposed methods were successfully applied to determine the drug in its pharmaceutical

  5. Determination and interference studies of bismuth by tungsten trap hydride generation atomic absorption spectrometry.

    PubMed

    Kula, Ibrahim; Arslan, Yasin; Bakirdere, Sezgin; Titretir, Serap; Kendüzler, Erdal; Ataman, O Yavuz

    2009-11-15

    The determination of bismuth requires sufficiently sensitive procedures for detection at the microg L(-1) level or lower. W-coil was used for on-line trapping of volatile bismuth species using HGAAS (hydride generation atomic absorption spectrometry); atom trapping using a W-coil consists of three steps. Initially BiH(3) gas is formed by hydride generation procedure. The analyte species in vapor form are transported through the W-coil trap held at 289 degrees C where trapping takes place. Following the preconcentration step, the W-coil is heated to 1348 degrees C; analyte species are released and transported to flame-heated quartz atom cell where the atomic signal is formed. In our study, interferences have been investigated in detail during Bi determination by hydride generation, both with and without trap in the same HGAAS system. Interferent/analyte (mass/mass) ratio was kept at 1, 10 and 100. Experiments were designed for carrier solutions having 1.0M HNO(3). Interferents such as Fe, Mn, Zn, Ni, Cu, As, Se, Cd, Pb, Au, Na, Mg, Ca, chloride, sulfate and phosphate were examined. The calibration plot for an 8.0 mL sampling volume was linear between 0.10 microg L(-1) and 10.0 microg L(-1) of Bi. The detection limit (3s/m) was 25 ng L(-1). The enhancement factor for the characteristic concentration (C(o)) was found to be 21 when compared with the regular system without trap, by using peak height values. The validation of the procedure was performed by the analysis of the certified water reference material and the result was found to be in good agreement with the certified values at the 95% confidence level.

  6. Microwave-enhanced cold vapor generation for speciation analysis of mercury by atomic fluorescence spectrometry.

    PubMed

    Wu, Li; Long, Zhou; Liu, Liwei; Zhou, Qin; Lee, Yong-Ill; Zheng, Chengbin

    2012-05-30

    A new and simple cold vapor generation technique utilizing microwave irradiation coupled with atomic fluorescence spectrometry is developed for the speciation analysis of mercury in biological and geological samples. In the presence of formic acid, inorganic mercury (Hg(2+)) and total mercury (both Hg(2+) and methylmercury (MeHg)) can be converted to mercury cold vapor (Hg(0)) by microwave irradiation without and with H(2)O(2), respectively. The cold vapor was subsequently released from the liquid phase and rapidly transported to an atomic fluorescence spectrometer for the mercury detection. Optimum conditions for vapor generation as well as interferences from concomitant ions were carefully investigated. The conventionally required evaporation of the remnants of acid or oxidants was avoided because no significant interferences from these substances were observed, and thus analyte loss and potential contamination were minimized. A limit of detection of 0.005 ng mL(-1) for total mercury or inorganic mercury was obtained. A precision of less than 3% (RSD) at 2 μg L(-1) of mercury species was typical. The accuracy of the method was validated by determination of mercury in geological and biological certified reference materials. The speciation analysis of Hg(2+) and MeHg was achieved by controlling the conditions of microwave-enhanced cold vapor generation and validated via determination of Certified Reference Materials DORM-2, DORM-3 and a real river water sample.

  7. Atomic Oxygen Abundance in Molecular Clouds: Absorption Toward Sagittarius B2

    NASA Technical Reports Server (NTRS)

    Lis, D. C.; Keene, Jocelyn; Phillips, T. G.; Schilke, P.; Werner, M. W.; Zmuidzinas, J.

    2001-01-01

    We have obtained high-resolution (approximately 35 km/s) spectra toward the molecular cloud Sgr B2 at 63 micrometers, the wavelength of the ground-state fine-structure line of atomic oxygen (O(I)), using the ISO-LWS instrument. Four separate velocity components are seen in the deconvolved spectrum, in absorption against the dust continuum emission of Sgr B2. Three of these components, corresponding to foreground clouds, are used to study the O(I) content of the cool molecular gas along the line of sight. In principle, the atomic oxygen that produces a particular velocity component could exist in any, or all, of three physically distinct regions: inside a dense molecular cloud, in the UV illuminated surface layer (PDR) of a cloud, and in an atomic (H(I)) gas halo. For each of the three foreground clouds, we estimate, and subtract from the observed O(I) column density, the oxygen content of the H(I) halo gas, by scaling from a published high-resolution 21 cm spectrum. We find that the remaining O(I) column density is correlated with the observed (13)CO column density. From the slope of this correlation, an average [O(I)]/[(13)CO] ratio of 270 +/- 120 (3-sigma) is derived, which corresponds to [O(I)]/[(13)CO] = 9 for a CO to (13)CO abundance ratio of 30. Assuming a (13)CO abundance of 1x10(exp -6) with respect to H nuclei, we derive an atomic oxygen abundance of 2.7x10(exp -4) in the dense gas phase, corresponding to a 15% oxygen depletion compared to the diffuse ISM in our Galactic neighborhood. The presence of multiple, spectrally resolved velocity components in the Sgr B2 absorption spectrum allows, for the first time, a direct determination of the PDR contribution to the O(I) column density. The PDR regions should contain O(I) but not (13)CO, and would thus be expected to produce an offset in the O(I)-(13)CO correlation. Our data do not show such an offset, suggesting that within our beam O(I) is spatially coexistent with the molecular gas, as traced by (13)CO

  8. Absolute nitrogen atom density measurements by two-photon laser-induced fluorescence spectroscopy in atmospheric pressure dielectric barrier discharges of pure nitrogen

    SciTech Connect

    Es-Sebbar, Et-Touhami; Sarra-Bournet, Christian; Naude, Nicolas; Gherardi, Nicolas; Massines, Francoise

    2009-10-01

    In this paper, two-photon absorption laser induced fluorescence spectroscopy is used to follow the nitrogen atom density in flowing dielectric barrier discharges fed with pure nitrogen and operating at atmospheric pressure. Two different dielectric barrier discharge regimes are investigated: the Townsend regime, which is homogeneous although operating at atmospheric pressure, and the more common filamentary regime. In both regimes, densities as high as 3x10{sup 14}/cm{sup 3} are detected. However, the N atoms kinetic formation depends on the discharge regime. The saturation level is reached more rapidly with a filamentary discharge. For a given discharge regime, the N atom density depends strongly on the energy dissipated in the plasma between the gas inlet and the measurement position, whether the energy is varied by varying the position of the measurements, the gas flow, or the dissipated power. Experiments performed in the postdischarge show that the N atom decay cannot be simply attributed to three-body recombination of atomic nitrogen with nitrogen molecules, meaning that other mechanisms such as surface recombination or gas impurities play a role.

  9. Theoretical studies on the vibrationally-resolved absorption and fluorescence spectra of H-Pyrene+ and H-Coronene+

    NASA Astrophysics Data System (ADS)

    Li, JunFeng; Tian, GuanJun; Luo, Yi; Cao, ZeXing

    2015-11-01

    H-Pyrene+ and H-Coronene+ are important carrier candidates for the diffuse interstellar band. In order to understand the observed absorption and fluorescence emission spectra of H-Pyrene+ and H-Coronene+, time-dependent density functional theory (TD-DFT) method and Franck-Condon approximation have been employed to simulate the corresponding vibrationally-resolved optical spectra. For H-Pyrene+, the calculated absorption, emission and 0-0 band energies are in good agreement with the experimental values. The strong absorption and emission vibrational peaks near the 0-0 band match well with the experiment peaks. A noticeable deviation for several weak peaks far away from the origin band is observed, as a result of the vibronic coupling with other excited states. For H-Coronene+, the predicted vibrationally resolved electronic absorption and emission spectra resemble very well their experimental counterparts spectra, allowing to fully assign the observed vibronic peaks.

  10. Determination of Hg, Cd, Mn, Pb and Sn in seafood by solid sampling Zeeman atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Detcheva, A.; Grobecker, K. H.

    2006-04-01

    Direct solid sampling Zeeman atomic absorption spectrometric methods were developed and applied to the determination of mercury, cadmium, manganese, lead and tin in seafood. All elements but mercury were measured by a third generation Zeeman atomic absorption spectrometry combined with an automatic solid sampler. In 3-field- and dynamic mode the calibrations concentration range was substantially extended and high amounts of analyte were detectable without laborious dilution of solid samples. The measurements were based on calibrations using certified reference materials of organic matrices. In case solid certified reference materials were not available calibration by aqueous standard solutions was proved to be an alternative. No matrix effects were observed under the optimized conditions. Results obtained were in good agreement with the certified values. Solid sampling Zeeman atomic absorption spectrometry proved to be a reliable, rapid and low-cost method for the control of trace elements in seafood.

  11. Application of atomic absorption spectroscopy for detection of multimetal traces in low-voltage electrical marks.

    PubMed

    Jakubeniene, Marija; Zakaras, Algirdas; Minkuviene, Zita Nijole; Benoshys, Alvydas

    2006-08-10

    Application of atomic absorption spectroscopy to detect multimetal traces in injured skin is a promising tool for investigation of fatalities caused by electrocution. The present paper is aimed at testing the reliability of this method for metal traces detection in electric current marks and is focused on study of peculiarities of metal penetration into the skin exposed to a current impact. Bare aluminum wire, tin-lead coated copper multistrand wire, and zinc-plated steel rope were used to make electrical marks on pig skin. It is demonstrated that amount of copper, zinc, lead, and iron may serve as statistically reliable indicators for the type of wire, which caused the electrical mark, in spite of the background content of these metals in the skin without injury. Different penetration rates for different metals contained in the wire inflicting an electrical mark were observed.

  12. Automation of preparation of nonmetallic samples for analysis by atomic absorption and inductively coupled plasma spectrometry

    NASA Technical Reports Server (NTRS)

    Wittmann, A.; Willay, G.

    1986-01-01

    For a rapid preparation of solutions intended for analysis by inductively coupled plasma emission spectrometry or atomic absorption spectrometry, an automatic device called Plasmasol was developed. This apparatus used the property of nonwettability of glassy C to fuse the sample in an appropriate flux. The sample-flux mixture is placed in a composite crucible, then heated at high temperature, swirled until full dissolution is achieved, and then poured into a water-filled beaker. After acid addition, dissolution of the melt, and filling to the mark, the solution is ready for analysis. The analytical results obtained, either for oxide samples or for prereduced iron ores show that the solutions prepared with this device are undistinguished from those obtained by manual dissolutions done by acid digestion or by high temperature fusion. Preparation reproducibility and analytical tests illustrate the performance of Plasmasol.

  13. The environmental effects of trace elements concentration in sea snails using atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    El-Amri, F. A.

    2003-05-01

    Water pollution bas increased in heavy industrialised areas. Most industrial water wastes end up in the sea. Monitoring the elemental composition in marine organisms, such as snails, provides the essential elements in living organisms and through the food chain to man. 50 samples of each of two kinds of snails have been collected from the west coast of Libya. Samples were digeste with nitric acid and the concentration of Copper, Iron, Magnesium and Zinc were determined by atomic absorption spectrometry. The results shows that Mg has the highest value while the Copper has the lowest in both kind of snaiis. A pattern of the trace elements concentration was investigated regarding the size and kind of snails.

  14. Determination of trace amounts of tin in geological materials by atomic absorption spectrometry

    USGS Publications Warehouse

    Welsch, E.P.; Chao, T.T.

    1976-01-01

    An atomic absorption method is described for the determination of traces of tin in rocks, soils, and stream sediments. A dried mixture of the sample and ammonium iodide is heated to volatilize tin tetraiodide -which is then dissolved in 5 % hydrochloric acid, extracted into TOPO-MIBK, and aspirated into a nitrous oxide-acetylene flame. The limit of determination is 2 p.p.m. tin and the relative standard deviation ranges from 2 to 14 %. Up to 20 % iron and 1000 p.p.m. Cu, Pb, Zn, Mn, Hg, Mo, V, or W in the sample do not interfere. As many as 50 samples can be easily analyzed per man-day. ?? 1976.

  15. Development of mixed-waste analysis capability for graphite furnace atomic absorption spectrophotometry

    SciTech Connect

    Bass, D.A.; TenKate, L.B.; Wroblewski, A.

    1995-03-01

    Graphite furnace atomic absorption spectrophotometer (GFAAS) are typically configured with ventilation to capture potentially toxic and corrosive gases emitted from the vaporization of sample aliquots. When radioactive elements are present, additional concerns (such as meeting safety guidelines and ALARA principles) must be addressed. This report describes a modification to a GFAAS that provides additional containment of vaporized sample aliquots. The modification was found to increase containment by a factor of 80, given expected operating conditions. The use of the modification allows more mixed-waste samples to be analyzed, permits higher levels of radioactive samples to be analyzed, or exposes the analyst to less airborne radioactivity. The containment apparatus was attached to a Perkin-Elmer Zeeman 5000 spectrophotometer for analysis of mixed-waste samples; however, it could also be used on other systems and in other applications where greater containment of vaporized material is desired.

  16. Determination of tributyltin in tissues and sediments by graphite furnace atomic absorption spectrometry

    SciTech Connect

    Stephenson, M.D.; Smith, D.R.

    1988-04-01

    A method for the determination of tributyltin (TBT) in tissue and sediments has been developed for environmental samples. The technique involves extraction with methylene chloride and isolation of TBT from mono- and dibutyltin with a sodium hydroxide wash. The TBT is then back extracted and converted to elemental Sn with nitric acid. Analysis is by Zeeman graphite furnace atomic absorption spectrophotometry. Recoveries of spiked samples were between 99% and 111% for mussel and fish tissues and 72% and 99% for various sediments. The limit of quantification was 0.0025 ..mu..g/g for tissue (on a wet weight basis). This technique was developed in response to their need to process large numbers of environmental samples with a minimum time investment.

  17. Determination of thallium in wine by electrothermal atomic absorption spectrometry after extraction preconcentration

    NASA Astrophysics Data System (ADS)

    Cvetković, Julijana; Arpadjan, Sonja; Karadjova, Irina; Stafilov, Trajče

    2002-06-01

    A simple method for extraction electrothermal atomic absorption spectroscopy (ETAAS) determination of Tl in wine is described. The wine sample is decomposed with a mixture of nitric acid and hydrogen peroxide and both thallium species Tl(I) and Tl(III) are extracted from 0.5 mol l -1 KI solution into iso-butyl methyl ketone (IBMK). Optimal parameters for ETAAS measurement of the iodide complexes extracted were defined for two different instruments: Perkin Elmer Zeeman 3030 (HGA 600) and Varian SpectrAA-880 (GTA-100). Modifiers of tartaric acid, Pd [ammoniumtetrachloropaladate (II)] or Ag (silver nitrate) were investigated for thermal stabilization of such extremely volatile species as iodide complexes of Tl. The analytical procedure developed permits 50-fold preconcentration and determination of 0.05 μg l -1 Tl in wine. The relative standard deviation ranges from 6 to 12% for the concentration range 0.2-1 μg l -1 Tl in wine.

  18. Removal of iron interferences by solvent extraction for geochemical analysis by atomic-absorption spectrophotometry

    USGS Publications Warehouse

    Zhou, L.; Chao, T.T.; Sanzolone, R.F.

    1985-01-01

    Iron is a common interferent in the determination of many elements in geochemical samples. Two approaches for its removal have been taken. The first involves removal of iron by extraction with methyl isobutyl ketone (MIBK) from hydrochloric acid medium, leaving the analytes in the aqueous phase. The second consists of reduction of iron(III) to iron(II) by ascorbic acid to minimize its extraction into MIBK, so that the analytes may be isolated by extraction. Elements of interest can then be determined using the aqueous solution or the organic extract, as appropriate. Operating factors such as the concentration of hydrochloric acid, amounts of iron present, number of extractions, the presence or absence of a salting-out agent, and the optimum ratio of ascorbic acid to iron have been determined. These factors have general applications in geochemical analysis by atomic-absorption spectrophotometry. ?? 1985.

  19. The direct determination of HgS by thermal desorption coupled with atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Coufalík, Pavel; Zvěřina, Ondřej; Komárek, Josef

    2016-04-01

    This research was aimed at the direct determination of HgS in environmental samples by means of thermal desorption coupled with atomic absorption spectrometry. Operating parameters of the apparatus used for thermal desorption (including a prototype desorption unit) are described in this work, as well as the procedure for measuring mercury release curves together with an evaluation of the analytical signal including two methods of peak integration. The results of thermal desorption were compared with HgS contents obtained by sequential extraction. The limits of quantification of the proposed method for the selective determination of the black and red forms of HgS were 4 μg kg- 1 and 5 μg kg- 1, respectively. The limit of quantification of red HgS in soils was 35 μg kg- 1. The developed analytical procedure was applied to soil and sediment samples from historical mining areas.

  20. Determination of some heavy metals by flame atomic absorption spectrometry before coprecipitation with neodymium hydroxide.

    PubMed

    Soylak, Mustafa; Kizil, Nebiye

    2011-01-01

    A procedure is described for the determination of trace amounts of Cd(II), Ni(II), Cu(II), Pb(II), Fe(III), Co(II), and Mn(II) that combines flame atomic absorption spectrometry with neodymium hydroxide coprecipitation. The influences of analytical parameters (amount of neodymium, pH of the model solutions, etc.) that affect quantitative recoveries of the analyte ions were investigated. The effects of concomitant ions were also examined. The detection limits for analytes were found in the range of 0.2-3.3 microg/L. The validation of the presented procedure was controlled by analysis of certified reference materials (National Institute of Standards and Technology 1570a spinach leaves and TMDA 54.4 fortified lake water). The applications of the procedure were performed by the analysis of water, food, and herbal plants from Turkey.

  1. Determination of cyanide by a flow injection analysis-atomic absorption spectrometric method.

    PubMed

    López Gómez, A V; Martínez Calatayud, J

    1998-10-01

    A new flow injection analysis (FIA) procedure is proposed for the indirect atomic absorption spectrometric determination of cyanide. The FIA manifold is based on the insertion of the sample into a distilled water carrier, then the sample flows through a solid-phase reactor filled with silver iodide entrapped in polymeric resin beads. The calibration graph is linear over the range 0.2-6.0 mg l-1 of cyanide (correlation coefficient 0.9974), the detection limit is 0.1 mg l-1, the sample throughput is 193 h-1 and the RSD is 0.8%. The method is simple, quick and more selective than other published FIA procedures. The reproducibility obtained by using different solid-phase reactors and solutions is in the range 2.2-3.1% (RSD). The method was applied to the determination of cyanide in commercial samples such as pharmaceutical formulations and industrial electrolytic baths.

  2. Determination of selenium in urine by hydride generation atomic absorption spectrometry.

    PubMed

    Navarro, M; Lopez, H; Lopez, M C; Perez, V

    1996-01-01

    A procedure has been developed for determination of total selenium in urine by hydride generation atomic absorption spectrometry. Mineralization was performed with a nitric acid-perchloric acid mixture on a thermostated digestion block. The method was validated by comparison with the method involving mineralization in a microwave acid digestion bomb containing nitric acid and small amounts of vanadium pentoxide. Se(VI) was reduced to Se(IV) by dissolution in 7N HCl. Sample recoveries, precision studies, and analyses of a certified reference material demonstrated the reliability and accuracy of this technique. Urine samples had selenium concentrations ranging from 4.6 to 50.3 micrograms/L. These values correspond to an average of 54.9 micrograms per person per day total ingested and bioavailable Se in the daily diet.

  3. Elimination of matrix effects in electrothermal atomic absorption spectrophotometric determinations of bismuth in serum and urine.

    PubMed

    Dean, S; Tscherwonyi, P J; Riley, W J

    1992-01-01

    A sensitive and precise electrothermal atomic absorption spectrophotometric method for determining bismuth concentration is described. Protein precipitation and the use of a palladium modifier reduce the problems of foaming and permit the use of a higher ashing temperature. The detection limit of the assay is 0.9 nmol/L. Total CVs (intra- and interassay) for serum ranged from 3.5% to 15.1% and for urine from 4.8% to 14.5% at concentrations of 60.0 and 6.0 nmol/L, respectively. Analytical recoveries of bismuth added to serum and urine were 102% and 103% over the same range. The method is robust and reproducible and can be accurately calibrated with aqueous standards.

  4. Liquid-phase microextraction combined with graphite furnace atomic absorption spectrometry: A review.

    PubMed

    de la Calle, Inmaculada; Pena-Pereira, Francisco; Lavilla, Isela; Bendicho, Carlos

    2016-09-14

    An overview of the combination of liquid-phase microextraction (LPME) techniques with graphite furnace atomic absorption spectrometry (GFAAS) is reported herein. The high sensitivity of GFAAS is significantly enhanced by its association with a variety of miniaturized solvent extraction approaches. LPME-GFAAS thus represents a powerful combination for determination of metals, metalloids and organometallic compounds at (ultra)trace level. Different LPME modes used with GFAAS are briefly described, and the experimental parameters that show an impact in those microextraction processes are discussed. Special attention is paid to those parameters affecting GFAAS analysis. Main issues found when coupling LPME and GFAAS, as well as those strategies reported in the literature to solve them, are summarized. Relevant applications published on the topic so far are included.

  5. [Determination of Cu, Zn and Fe in Huaiyao by suspension sampling-flame atomic absorption spectrometry].

    PubMed

    Wei, Wei; Qu, Ling-bo; Li, Jian-jun; Li, Yan-hong

    2002-10-01

    A new method--suspension sampling technique was applied to flame atomic absorption spectrometry and was successfully used to determine Cu, Zn, Fe in Huaiyao. Then studied the choice of suspension agent and elimination of chemical interference. The huaiyao sample was suspended in agar sol, and injected into air-acetylene flame by using standard addition method to determine Cu, Zn, Fe. Determined results were consistent with those obtained by HNO3 + H2SO4 + HClO4 method. The t-test showed that no obvious difference was found between the two methods. Displacement of HNO3 + H2SO4 + HClO4 method by suspension sampling method for the sample pretreatment is possible. This method is convenient, rapid and accurate.

  6. [Determination of inorganic elements in different parts of Sonchus oleraceus L by flame atomic absorption spectrometry].

    PubMed

    Wang, Nai-Xing; Cui, Xue-Gui; Du, Ai-Qin; Mao, Hong-Zhi

    2007-06-01

    Flame atomic absorption spectrometry with air-acetylene flame was used for the determination of inorganic metal elements in different parts ( flower, leaf, stem and root) of Sonchus oleraceus L. The contents of Ca, Mg, K, Na, Fe, Mn, Cu, Zn, Cr, Co, Ni, Pb and Cd in the flower, leaf, stem and root of Sonchus oleraceus L were compared. The order from high to low of the additive weight (microg x g(-1)) for the 13 kinds of metal elements is as follows: leaf (77 213.72) > flower (47 927.15) > stem(42 280.99) > root (28 131.18). From the experimental results it was found that there were considerable differences in the contents of the metal elements in different parts, and there were richer contents of Fe, Zn, Mn and Cu in root and flower, which are necessary to human health, than in other parts.

  7. An atomic-absorption method for the determination of gold in large samples of geologic materials

    USGS Publications Warehouse

    VanSickle, Gordon H.; Lakin, Hubert William

    1968-01-01

    A laboratory method for the determination of gold in large (100-gram) samples has been developed for use in the study of the gold content of placer deposits and of trace amounts of gold in other geologic materials. In this method the sample is digested with bromine and ethyl ether, the gold is extracted into methyl isobutyl ketone, and the determination is made by atomicabsorption spectrophotometry. The lower limit of detection is 0.005 part per million in the sample. The few data obtained so far by this method agree favorably with those obtained by assay and by other atomic-absorption methods. About 25 determinations can be made per man-day.

  8. Determination of soluble aluminium concentration in alkaline humic water using atomic absorption spectrophotometry.

    PubMed

    Nguyen, K L; Lewis, D M; Jolly, M; Robinson, J

    2004-11-01

    The steps of the standard method to determine soluble aluminium concentration are filtering, followed by acidifying, then analysing with the atomic absorption spectrophotometer (AAS). When applied to alkaline humic water, acidification gives rise to the formation of humic acid as a brown particulate matter. Of the total soluble aluminium in the original water, 49-61% forms complexes with the particulate humic acid upon acidification. Although the AAS is capable of detecting the binding aluminium, the particulate nature of humic acid easily induces inaccurate readings as a result of the non-uniform distribution of the particulate matter. A more precise analysis of soluble aluminium concentration of alkaline humic water is shown to be achievable in basicified solutions instead. Basicified solutions keep humic acid in the soluble form; hence maintain the homogeneity of the sample.

  9. Determination of arsenic in vegetable samples by hydride generation atomic absorption spectrometry

    SciTech Connect

    Navarro, M.; Lopez, M.C.; Lopez, H.; Sanchez, M.

    1992-11-01

    A procedure is described for the determination of arsenic in vegetable samples by hydride generation atomic absorption spectrometry. The samples are mineralized in a microwave acid digestion bomb with nitric acid in the presence of small amounts of vanadium pentoxide. The determination of arsenic is made by the standard addition method. A certified reference sample is analyzed, and the result obtained agreed well with the certified value. The detection limit (dry weight) was about 0.020 {mu}g/g. Reproducibility relative standard deviations ranged from 6.45% at 0.152 {mu}g As/g to 8.31% at 0.059 {mu}g As/g. The concentrations of arsenic in vegetable samples ranged from 0.029 to 0.444 {mu}g/g (fresh weight). 24 refs., 4 tabs.

  10. Slurry sampling electrothermal atomic absorption spectrometry as screening method for chromium in compost.

    PubMed

    Laborda, F; Górriz, M P; Castillo, J R

    2004-10-20

    Ultrasonic slurry sample introduction was applied to the determination of total chromium in composted materials by electrothermal atomic absorption spectrometry (ETAAS). The effect of grinding on the heterogeneity of the test samples and on the attainable precision was studied. The repeatability was influenced by the heterogeneity of the test samples at the mug-level, the R.S.D. of the measurements being 15%. The reproducibility depended on the heterogeneity of the test sample at the mg level, and it could be improved from 11 to 7% by increasing the grinding time. The characteristic mass was 2.6pg and the detection limit for the optimised procedure at the 0.04% (w/v) slurry concentration, 370ngg(-1). Good agreement with a certified reference material and with the conventional microwave assisted digestion method was found by using external calibration with aqueous standards. The performance of the method for screening purposes was evaluated.

  11. Determination of lead in fish samples by slurry sampling electrothermal atomic absorption spectrometry.

    PubMed

    Huang, S J; Jiang, S J

    2000-08-01

    Ultrasonic slurry sampling electrothermal atomic absorption spectrometry (USS-ETAAS) was been applied to the determination of lead in several fish samples. The influences of instrument operating conditions and slurry preparation on the signal were examined. Palladium and ammonium nitrate were used as the modifier to improve the signal. Since the sensitivity to lead in various fish slurries and aqueous solutions was different, the standard additions method was used for the determination of lead in these fish samples. The method was applied to the determination of lead in dogfish muscle reference material (DORM-2) and a swordfish muscle sample purchased from the local market. The analysis results agreed with the reference value. The accuracy was better than 6%. The precision between sample replicates was better than 16% with the USS-ETAAS method. The detection limit of lead estimated from standard additions curve was about 0.053-0.058 microgram g-1 in different samples.

  12. Determination of calcium, magnesium and zinc in unused lubricating oils by atomic absorption spectroscopy.

    PubMed

    Udoh, A P

    1995-12-01

    Varying concentrations of lanthanum and strontium were added to solutions of ashed unused lubricating oils for the determination of calcium, magnesium and zinc content using flame atomic absorption spectrophotometry. At least 3000 mug g(-1) of lanthanum or strontium was required to completely overcome the interference of the phosphate ion, PO(3-)(4), and give peak values for calcium. The presence of lanthanum or strontium did not cause an appreciable increase in the amount of magnesium and zinc obtained from the analyses. The method is fast and reproducible, and the coefficients of variation calculated for the elements using one of the samples were 1.6% for calcium, 3.5% for magnesium and 0.2% for zinc. Results obtained by this method were better than those obtained by other methods for the same samples.

  13. Determination of palladium by graphite furnace atomic absorption spectroscopy without matrix matching.

    PubMed

    Jia, X; Wang, T; Wu, J

    2001-05-30

    A graphite furnace atomic absorption spectroscopy method for the analysis of the palladium (Pd) content in bulk pharmaceutical drug substances and their intermediates prepared in aqueous solutions is extended to samples prepared in acetonitrile (ACN) and ACN-water mixtures as well to samples prepared in dimethyl sulfoxide (DMSO) and DMSO-water mixtures. The Pd content in samples solubilized in these solvents can be accurately determined with calibration established with standards prepared in aqueous solutions without matrix matching or using the method of standard additions. The validity of this method is demonstrated by spike recovery studies and by the agreement with results for the same samples prepared in these solvents, in concentrated nitric acid, and prepared by a microwave digestion system.

  14. A summary of transition probabilities for atomic absorption lines formed in low-density clouds

    NASA Technical Reports Server (NTRS)

    Morton, D. C.; Smith, W. H.

    1973-01-01

    A table of wavelengths, statistical weights, and excitation energies is given for 944 atomic spectral lines in 221 multiplets whose lower energy levels lie below 0.275 eV. Oscillator strengths were adopted for 635 lines in 155 multiplets from the available experimental and theoretical determinations. Radiation damping constants also were derived for most of these lines. This table contains the lines most likely to be observed in absorption in interstellar clouds, circumstellar shells, and the clouds in the direction of quasars where neither the particle density nor the radiation density is high enough to populate the higher levels. All ions of all elements from hydrogen to zinc are included which have resonance lines longward of 912 A, although a number of weaker lines of neutrals and first ions have been omitted.

  15. Evaluation of a carbon-rod atomizer for routine determination of trace metals by atomic-absorption spectroscopy applications to analysis of lubricating oil and crude oil.

    PubMed

    Hall, G; Bratzel, M P; Chakrabarti, C L

    1973-08-01

    A carbon-rod atomizer (CRA) fitted with a 'mini-Massmann' carbon rod was evaluated for routine analysis of petroleum and petroleum products for trace metal content by atomic-absorption spectroscopy. Aspects investigated included sensitivity, detection limit, effect of solvent type, and interferences. The results of analysis of oil samples with this technique were compared with those obtained by other techniques. Metals studied were silver, copper, iron, nickel, and lead. Sensitivity and detection limit values obtained with the CRA were similar to those obtained with the carbon-filament atomizer. Strong 'solvent effects' were observed as well as interference by cations. On the basis of this study, design changes for the CRA are suggested, with the object of minimizing 'solvent effects' and interferences, increasing the atomization efficiency, and increasing the residence time of the atomic vapour in the optical path of the instrumental system.

  16. Non-dispersive atomic-fluorescence spectrometry of trace amounts of bismuth by introduction of its gaseous hydride into a premixed argon (entrained air)-hydrogen flame.

    PubMed

    Kobayashi, S; Nakahara, T; Musha, S

    1979-10-01

    A method has been developed for the determination of bismuth by generation of its gaseous hydride and introduction of the hydride into a premixed argon (entrained air)-hydrogen flame, the atomic-fluorescence lines from which are all detected by use of a non-dispersive system. The detection limit is 5 pg/ml, or 0.1 ng of bismuth, but the reagent blank found in a 20-ml sample volume was approximately 2 ng of bismuth. Analytical working curves obtained by measuring peak-heights and integrated peak-areas of the signals are linear over a range of about four orders of magnitude from the detection limit. Perchloric, phosphoric and sulphuric acids up to 2.0M concentration give no interference, but nitric acid gives slight depression of the signal. The presence of silver, gold, nickel, palladium, platinum, selenium and tellurium in 1000-fold ratio to bismuth causes pronounced depression of the signal, whereas mercury and tin slightly enhance the atomic-fluorescence signal. The method has been applied to the determination of bismuth in aluminium-base alloys and sulphide ores with use of the standard additions method. The results are in good agreement with those obtained by flame atomic-absorption spectrometry and optical emission spectrometry with an inductively coupled plasma.

  17. Determination of mercury in carbon black by cold vapor atomic absorption spectrometry.

    PubMed

    Hepp, Nancy M

    2006-01-01

    Recently, a new color additive, D&C Black No. 2, a high-purity furnace black in the general category of carbon blacks, was listed as a color subject to batch certification by the U.S. Food and Drug Administration. A simple procedure was developed to determine mercury (Hg) in D&C Black No. 2, which is limited by specification to not more than 1 ppm Hg. The method uses partial acid digestion followed by cold vapor atomic absorption and was developed by modifying a method used for other color additives. The carbon black samples are treated with a mixture of nitric and hydrochloric acids and heated by microwave in sealed Teflon vessels. The resulting solutions, which are stable to Hg loss for at least 1 week, are diluted and analyzed for Hg using cold vapor atomic absorption spectrometry. Validation was performed by spiking carbon black samples with inorganic Hg (HgNO3) at levels from 0.1 to 1.5 microg/g, and by analyzing 2 standard reference materials. At the specification level of 1 ppm Hg (1 microg Hg/g), the 95% confidence interval was +/-0.01 ppm Hg (0.01 microg Hg/g). The method developed in this study gave good results for very difficult-to-analyze materials, such as coal standard reference materials and carbon black. By eliminating volatility and adsorption factors through the formation of HgCl4(-2) complexes, one can avoid using extremely hazardous acids such as HF and HClO4.

  18. Free-free absorption of infrared radiation in collisions of electrons with neutral rare-gas atoms

    NASA Technical Reports Server (NTRS)

    Stallcop, J. R.

    1974-01-01

    A relationship between the inverse bremsstrahlung absorption cross section and the electron neutral momentum transfer cross section has been utilized to determine the infrared free-free continuum absorption coefficient for the negative ions of helium, neon, argon, krypton, and xenon. The values of the momentum transfer cross section for this calculation have been obtained from experimental measurements. Analytical expressions for the absorption coefficient have also been developed. From the results of this calculation, it is possible to determine the absorption coefficient per unit electron density per neutral atom for temperatures in the range from 2500 to 25,000 K. The results are compared with those from tabulations of previous calculations and those computed from theoretical values of the phase shifts for the elastic scattering of electrons by neutral atoms.

  19. X-ray atomic absorption of cesium and xenon in the L-edge region

    SciTech Connect

    Kodre, A.; Padeznik Gomilsek, J.; Arcon, I.; Aquilanti, G.

    2010-08-15

    X-ray absorption of atomic cesium is measured in the L-edge region, using a beryllium-window cell for cesium vapor. For comparison, absorption in Xe gas in the same energy region is remeasured with improved signal-to-noise ratio. By combining deconvolution and modeling, the edge profiles are studied to determine the threshold energies and the shape of the edge apex with exponential slope of the high-energy flank. In both elements, multielectron excitations show the same basic ordering in compact groups, largely independent of the core-hole subshell, following the energy sequence of coexcited valence and subvalence orbitals. The main effect of 6s electron in Cs, apart from 2(s,p)6s excitation, is the enhancement of single- as well as some multielectron resonant channels. The spectra of both elements show the ''polarization effect'': a convex basic curvature of the L{sub 2} and L{sub 3} segments, a concave L{sub 1} segment. Previously, Kutzner demonstrated a convincing theoretical explanation of the effect on Xe in a relativistic random-phase approximation with relaxation involving overlap integrals with continuum [Rad. Phys. Chem. 70, 95 (2004)].

  20. In situ atomic force microscopy observation of hydrogen absorption/desorption by Palladium thin film

    NASA Astrophysics Data System (ADS)

    Matsumoto, Itoko; Sakaki, Kouji; Nakamura, Yumiko; Akiba, Etsuo

    2011-12-01

    Grain structure changes in Pd thin film during hydrogen absorption and desorption were observed by in situ atomic force microscopy. The as-sputtered film had a smooth flat surface with 20-30 nm grains. Film that absorbed hydrogen showed buckling, caused by the compressive stress due to lattice expansion as Pd metal reacted with hydrogen to form the hydride. Grains on the buckles were agglomerated and deformed unlike those on flat areas beside the buckles. Film that absorbed and then desorbed hydrogen still showed some buckling; however, many buckles shrank and flattened when the compressive stress of lattice expansion was released during desorption. On both the remaining and the shrunken buckles, grain agglomeration was retained; whereas, the deformed grains reverted back to their original form. X-ray diffraction indicated compressive residual stress in the as-sputtered film and tensile residual stress in the film after hydrogen absorption/desorption. These results indicate that irreversible grain agglomeration is related to residual tensile stress in the film although agglomeration occurs only on the buckled areas.

  1. Assessing the engagement, learning, and overall experience of students operating an atomic absorption spectrophotometer with remote access technology.

    PubMed

    Erasmus, Daniel J; Brewer, Sharon E; Cinel, Bruno

    2015-01-01

    The use of internet-based technologies in the teaching of laboratories has emerged as a promising education tool. This study evaluated the effectiveness of using remote access technology to operate an atomic absorption spectrophotometer in analyzing the iron content in a crude myoglobin extract. Sixty-two students were surveyed on their level of engagement, learning, and overall experience. Feedback from students suggests that the use of remote access technology is effective in teaching students the principles of chemical analysis by atomic absorption spectroscopy.

  2. Analytical application of 2f-wavelength modulation for isotope selective diode laser graphite furnace atomic absorption spectroscopy.

    PubMed

    Wizemann, H D

    2000-01-01

    Experiences in the analytical application of the 2f-wavelength modulation technique for isotope selective atomic absorption spectroscopy in a graphite furnace are reported. Experimental as well as calculated results are presented, mainly for the natural lithium isotopes. Sensitivity, linearity, and (isotope) selectivity are studied by intensity modulation and wavelength modulation. High selectivities can be attained, however, on the cost of detection power. It is shown that the method enables the measurement of lithium isotope ratios larger than 2000 by absorption in a low-pressure graphite tube atomizer.

  3. Franck-Condon factors perturbed by damped harmonic oscillators: Solvent enhanced X {sup 1}A{sub g} ↔ A{sup 1}B{sub 1u} absorption and fluorescence spectra of perylene

    SciTech Connect

    Wang, Chen-Wen; Zhu, Chaoyuan Lin, Sheng-Hsien; Yang, Ling; Yu, Jian-Guo

    2014-08-28

    Damped harmonic oscillators are utilized to calculate Franck-Condon factors within displaced harmonic oscillator approximation. This is practically done by scaling unperturbed Hessian matrix that represents local modes of force constants for molecule in gaseous phase, and then by diagonalizing perturbed Hessian matrix it results in direct modification of Huang–Rhys factors which represent normal modes of solute molecule perturbed by solvent environment. Scaling parameters are empirically introduced for simulating absorption and fluorescence spectra of an isolated solute molecule in solution. The present method is especially useful for simulating vibronic spectra of polycyclic aromatic hydrocarbon molecules in which hydrogen atom vibrations in solution can be scaled equally, namely the same scaling factor being applied to all hydrogen atoms in polycyclic aromatic hydrocarbons. The present method is demonstrated in simulating solvent enhanced X {sup 1}A{sub g} ↔ A{sup 1}B{sub 1u} absorption and fluorescence spectra of perylene (medium-sized polycyclic aromatic hydrocarbon) in benzene solution. It is found that one of six active normal modes v{sub 10} is actually responsible to the solvent enhancement of spectra observed in experiment. Simulations from all functionals (TD) B3LYP, (TD) B3LYP35, (TD) B3LYP50, and (TD) B3LYP100 draw the same conclusion. Hence, the present method is able to adequately reproduce experimental absorption and fluorescence spectra in both gas and solution phases.

  4. Direct determination and speciation of mercury compounds in environmental and biological samples by carbon bed atomic absorption spectroscopy

    SciTech Connect

    Skelly, E.M.

    1982-01-01

    A method was developed for the direct determination of mercury in water and biological samples using a unique carbon bed atomizer for atomic absorption spectroscopy. The method avoided sources of error such as loss of volatile mercury during sample digestion and contamination of samples through added reagents by eliminating sample pretreatment steps. The design of the atomizer allowed use of the 184.9 nm mercury resonance line in the vacuum ultraviolet region, which increased sensitivity over the commonly used spin-forbidden 253.7 nm line. The carbon bed atomizer method was applied to a study of mercury concentrations in water, hair, sweat, urine, blood, breath and saliva samples from a non-occupationally exposed population. Data were collected on the average concentration, the range and distribution of mercury in the samples. Data were also collected illustrating individual variations in mercury concentrations with time. Concentrations of mercury found were significantly higher than values reported in the literature for a ''normal'' population. This is attributed to the increased accuracy gained by eliminating pretreatment steps and increasing atomization efficiency. Absorption traces were obtained for various solutions of pure and complexed mercury compounds. Absorption traces of biological fluids were also obtained. Differences were observed in the absorption-temperatures traces of various compounds. The utility of this technique for studying complexation was demonstrated.

  5. Atomic-scale roughness of Li metal surface evident in soft X-ray absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Prendergast, David; Wan, Liwen; Liang, Yufeng; Chuang, Yi-De; Qiao, Ruimin; Yan, Shishen; Yang, Wanli

    2015-03-01

    Realizing Li metal electrodes depends on fundamental understanding and efficient control of surface properties, which requires reliable characterization of the Li metal surface. Controlled experiments of Li K-edge soft X-ray absorption spectroscopy (XAS) reveal evidence of steady oxidation of the Li metal surface even under ultrahigh vacuum (UHV) conditions. The XAS of the short-lived Li metal surface, prepared by in-situ scratching, exhibits a prominent peak at 55.6 eV, more intense and at a slightly higher energy than the first peak expected for bulk Li metal at 55 eV. First-principles XAS calculations explain the origin of both the increased intensity and energy shift. This required the use of surface structural models with under-coordinated Li atoms and an estimated 4 Åinelastic mean-free-path for Auger electrons, implying extreme surface sensitivity of the measurements to the first 2-3 atomic layers. This work provides a benchmark on both experiment and theory for further studies of Li and other reactive metal surfaces, which are currently under scrutiny for next-generation energy storage devices. DP, LW, and YL acknowledge support from the Joint Center for Energy Storage Research, an Energy Innovation Hub funded by the US Dept. of Energy, Office of Science, Basic Energy Sciences.

  6. Determination of trace impurities in titanium dioxide by slurry sampling electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Dong, Huang Mao; Krivan, Viliam; Welz, Bernhard; Schlemmer, Gerhard

    1997-10-01

    A slurry sampling electrothermal atomic absorption spectrometry method for the determination of Al, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, Sr, Tl and Zn in powdered titanium dioxide is described. The behaviour of the titanium matrix in the atomizer and its interferences with the determination of Al, Fe, Co, Ni and Mn were studied. A tungsten carbide modified graphite tube was used to improve the signal shape and the repeatability for the determination of Fe. For all elements, except for Cd and Pb, quantification by a calibration curve established with aqueous standards was possible. No chemical modifier was used throughout in order to minimize contamination. For the contamination risk elements such as Ca, Fe, K, Mg, Na and Zn, the slurry sampling technique allows to achieve limits of detection (3 σ of the blank) 5-20 times lower than the solution technique, resulting for these elements in values of 1, 3, 0.5, 0.5, 0.9 and 2 ng g -1, respectively, and, generally being in the range of 0.2 ng g -1 (Cd) to 10 ng g -1 (Al and Tl). The results obtained by the slurry sampling technique are compared with those of other independent methods including four solution methods and neutron activation analysis.

  7. Determination of selenium in human spermatozoa and prostasomes using base digestion and electrothermal atomic absorption spectrophotometry.

    PubMed

    Suistomaa, U; Saaranen, M; Vanha-Perttula, T

    1987-10-15

    A method for the determination of selenium in human spermatozoa and prostasomes is described. The samples were digested with 25% (w/v) tetramethylammonium hydroxide (TMAH) in methanol and analyzed by atomic absorption spectrometry with electrothermal atomization and Zeeman background correction (ET-AAS). Nickel was used as a matrix modifier. Calibration was performed using the matrix-based calibration curve. The TMAH-digestion method agreed well with a conventional digestion procedure using concentrated nitric acid. The TMAH-digestion does not require heating or strong acids and it was suitable for small biological samples. The average recovery of added selenium in spermatozoan digests was 95.1 +/- 5.2% (n = 5). The coefficient of variation was 9.1% (n = 21). The accuracy of the method tested with the NBS standard 1577 (bovine liver, certified at 1.1 +/- 0.1 micrograms Se/g) resulted in a value of 0.98 +/- 0.10 micrograms Se/g (n = 16). The method was further tested in an interlaboratory comparison study.

  8. Electronically excited rubidium atom in helium clusters and films. II. Second excited state and absorption spectrum.

    PubMed

    Leino, Markku; Viel, Alexandra; Zillich, Robert E

    2011-01-14

    Following our work on the study of helium droplets and film doped with one electronically excited rubidium atom Rb(∗) ((2)P) [M. Leino, A. Viel, and R. E. Zillich, J. Chem. Phys. 129, 184308 (2008)], we focus in this paper on the second excited state. We present theoretical studies of such droplets and films using quantum Monte Carlo approaches. Diffusion and path integral Monte Carlo algorithms combined with a diatomics-in-molecule scheme to model the nonpair additive potential energy surface are used to investigate the energetics and the structure of Rb(∗)He(n) clusters. Helium films as a model for the limit of large clusters are also considered. As in our work on the first electronic excited state, our present calculations find stable Rb(∗)He(n) clusters. The structures obtained are however different with a He-Rb(∗)-He exciplex core to which more helium atoms are weakly attached, preferentially on one end of the core exciplex. The electronic absorption spectrum is also presented for increasing cluster sizes as well as for the film.

  9. Determination of silicon in serum and urine by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Huang, Zhuo-er

    1995-09-01

    A sensitive, simple and accurate method for the routine determination of trace silicon in serum and urine by Zeeman electrothermal atomic absorption spectrometry is described. The samples are directly determined after 20-fold dilution of serum and 100-fold dilution of urine. No L'vov platform is used. The signal enhancement of silicon atomization in pyrolytic graphite coated graphite tubes is achieved by using a mixture of calcium chloride and lanthanum nitrate as chemical modifier. The interferences arising from the biological matrices have been eliminated by the addition of ammonium dihydrogenphosphate in the sample solutions. The aqueous calibration curve is linear to at least 300 μg l -1, the characteristic mass is 37 pg (integrated absorbance signal), whereas the detection limit (3SD) is 1.5 μg l -1 for silicon in both diluted serum and urine samples. The recoveries of silicon added to the diluted samples are 101 ± 1.8% for sera and 98.2 ± 3.5% for the urine specimens, independent of the dilution ratio. The silicon measurement results for the serum and urine from healthy adults and for the serum from the patients with chronic renal failure on hemodialysis are presented.

  10. Determination of mercury(II) ion by electrochemical cold vapor generation atomic absorption spectrometry.

    PubMed

    Arbab-Zavar, M Hosein; Rounaghi, G Hosein; Chamsaz, Mahmoud; Masrournia, Mahboube

    2003-05-01

    A technique for determination of mercury is described; it is based on electrolytic reduction of Hg(II) ion on a graphite cathode, the trapping of mercury vapor and its volatilization into a quartz tube aligned in the optical path of an atomic absorption spectrometer. The electrochemical cell consisted of a graphite cathode and an anode operating with constant direct current for the production of mercury atoms. A pre-activated graphite rod was used as the cathode material. The optimum conditions for electrochemical generation of mercury cold vapor (the electrolysis time and current, the flow rate, the type of electrode and electrolyte) were investigated. The characteristic electrochemical data with chemical cold vapor using NaBH4-acid were compared. The presence of cadmium(II), arsenic(III), antimony(III), selenium(IV), bismuth(III), silver(I), lead(II), lithium(I), sodium(I) and potassium(I) showed interference effects which were eliminated by suitable separation techniques. The calibration curve is linear over the range of 5-90 ng ml(-1) mercury(II). The detection limit is 2 ng ml(-1) of Hg(II) and the RSD is 2.5% (n = 10) for 40 ng ml(-1). The accuracy and recovery of the method were investigated by analyzing spiked tap water and river water.

  11. Determination of lead in fine particulates by slurry sampling electrothermal atomic absorption spectrometry.

    PubMed

    Yu, J C; Ho, K F; Lee, S C

    2001-01-02

    A simple method for determining lead in fine particulates (PM2.5) by using electrothermal atomic absorption spectrometry (ETAAS) has been developed. Particulates collected on Nuclepore filter by using a dichotomous sampler were suspended in diluted nitric acid after ultrasonic agitation. The dislodging efficiency is nearly 100% after agitation for 5 min. In order to study the suspension behavior of PM2.5 in solvents, a Brookhaven ZetaPlus Particle Size Analyzer was used to determine the particle size distribution and suspension behavior of air particulates in the solvent. The pre-digestion and modification effect of nitric acid would be discussed. Palladium was added as a chemical modifier and the temperature program of ETAAS was changed in order to improve the recovery. The slurry was introduced directly into a graphite tube for atomization. The metal content in the sample was determined by the standard addition method. In addition, a conventional acid digestion procedure was applied to verify the efficiency of the slurry sampling method. It offers a quick and efficient alternative method for heavy metal characterization in fine particulates.

  12. Determination of tellurium in indium antimonide semiconductor material by electrothermal atomic absorption spectrometry.

    PubMed

    Shiue, M Y; Sun, Y C; Yang, M H

    2001-08-01

    A method for the determination of the dopant concentration of tellurium in dissolved indium antimonide semiconductor material by electrothermal atomic absorption spectrometry (ETAAS) was developed. Efforts were made to investigate the optimal conditions of the furnace heating program and the effect of palladium modifier on the variation of tellurium and the background absorbance. According to the results obtained, the presence of palladium chemical modifier in the analysis of indium antimonide allowed the successful retention of tellurium in the graphite tube, and the optimum mass of palladium modifier was found to be dependent on the sample matrix concentration. The absorbance profile of tellurium and the background level were significantly improved when a pyrolysis temperature of 1100 degrees C and an atomization temperature of 2200 degrees C were employed in the optimized heating program. With the use of this method, a detection limit of 0.8 microg g(-1) tellurium in indium antimonide could be achieved. The applicability of the proposed method was evaluated by comparison with two independent methods, i.e. slurry sampling-ETAAS and ICP-MS. From the good agreement between the results, it was demonstrated that the proposed method is suitable for the determination of typical dopant concentrations of tellurium in indium antimonide.

  13. High-speed laser-induced fluorescence and spark plug absorption sensor diagnostics for mixing and combustion studies in engines.

    PubMed

    Cundy, Michael; Schucht, Torsten; Thiele, Olaf; Sick, Volker

    2009-02-01

    Simultaneous high-speed in-cylinder measurements of laser-induced fluorescence of biacetyl as a fuel tracer and mid-infrared broadband absorption of fuel and combustion products (water and carbon dioxide) using a spark plug probe are compared in an optical engine. The study addresses uncertainties and the applicability of absorption measurements at a location slightly offset to the spark plug when information about mixing at the spark plug is desired. Absorbance profiles reflect important engine operation events, such as valve opening and closing, mixing, combustion, and outgassing from crevices.

  14. NARROW Na AND K ABSORPTION LINES TOWARD T TAURI STARS: TRACING THE ATOMIC ENVELOPE OF MOLECULAR CLOUDS

    SciTech Connect

    Pascucci, I.; Simon, M. N.; Edwards, S.; Heyer, M.; Rigliaco, E.; Hillenbrand, L.; Gorti, U.; Hollenbach, D.

    2015-11-20

    We present a detailed analysis of narrow Na i and K i absorption resonance lines toward nearly 40 T Tauri stars in Taurus with the goal of clarifying their origin. The Na i λ5889.95 line is detected toward all but one source, while the weaker K i λ7698.96 line is detected in about two-thirds of the sample. The similarity in their peak centroids and the significant positive correlation between their equivalent widths demonstrate that these transitions trace the same atomic gas. The absorption lines are present toward both disk and diskless young stellar objects, which excludes cold gas within the circumstellar disk as the absorbing material. A comparison of Na i and CO detections and peak centroids demonstrates that the atomic gas and molecular gas are not co-located, the atomic gas being more extended than the molecular gas. The width of the atomic lines corroborates this finding and points to atomic gas about an order of magnitude warmer than the molecular gas. The distribution of Na i radial velocities shows a clear spatial gradient along the length of the Taurus molecular cloud filaments. This suggests that absorption is associated with the Taurus molecular cloud. Assuming that the gradient is due to cloud rotation, the rotation of the atomic gas is consistent with differential galactic rotation, whereas the rotation of the molecular gas, although with the same rotation axis, is retrograde. Our analysis shows that narrow Na i and K i absorption resonance lines are useful tracers of the atomic envelope of molecular clouds. In line with recent findings from giant molecular clouds, our results demonstrate that the velocity fields of the atomic and molecular gas are misaligned. The angular momentum of a molecular cloud is not simply inherited from the rotating Galactic disk from which it formed but may be redistributed by cloud–cloud interactions.

  15. Determination of some antihistaminic drugs by atomic absorption spectrometry and colorimetric methods.

    PubMed

    El-Kousy, N; Bebawy, L I

    1999-08-01

    Atomic absorption spectrometry (AAS) and colourimetric methods have been developed for the determination of pizotifen (I), ketotifen (II) and loratadine (III). The first method depends on the reaction of the three drugs (I); (II) and (III) with cobalt thiocyanate reagent at pH 2 to give ternary complexes. These complexes are readily extracted with organic solvent and estimated by indirect atomic absorption method via the determination of the cobalt content in the formed complex after extraction in 0.1 M hydrochloric acid. It was found that the three drugs can be determined in the concentration ranges from 10 to 74, 12 to 95 and 10 to 93 microg ml(-1) with mean percentage recovery of 99.71+/-0.87, 99.70+/-0.79 and 99.62+/-0.75%, respectively. The second method is based on the formation of orange red ion pairs as a result of the reaction between (I); (II) and (III) and molybdenum thiocyanate with maximum absorption at 469.5 nm in dichloromethane. Appropriate conditions were established for the colour reaction. Under the proposed conditions linearity was obeyed in the concentration ranges 3.5-25, 5-37.5 and 2.5-22.5 microg ml(-1) with mean percentage recovery of 99.60+/-0.41, 100.11+/-0.43 and 99.31+/-0.47% for (I): (II) and (III), respectively. The third method depends on the formation of radical ion using 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ). The colour formed was measured at 588 nm for the three drugs (I); (II) and (III), respectively. The method is valid in concentration range 10-80 microg ml(-1) with mean percentage recovery 99.75+/-0.44, 99.94+/-0.72 and 99.17+/-0.36% for (I); (II) and (III), respectively. The proposed methods were applied to the analysis of pharmaceutical preparations. The results obtained were statistically analysed and compared with those obtained by applying the official and reference methods.

  16. Mini-Column Ion-Exchange Separation and Atomic Absorption Quantitation of Nickel, Cobalt, and Iron: An Undergraduate Quantitative Analysis Experiment.

    ERIC Educational Resources Information Center

    Anderson, James L.; And Others

    1980-01-01

    Presents an undergraduate quantitative analysis experiment, describing an atomic absorption quantitation scheme that is fast, sensitive and comparatively simple relative to other titration experiments. (CS)

  17. Absorption and fluorescence of PRODAN in phospholipid bilayers: a combined quantum mechanics and classical molecular dynamics study.

    PubMed

    Cwiklik, Lukasz; Aquino, Adelia J A; Vazdar, Mario; Jurkiewicz, Piotr; Pittner, Jiří; Hof, Martin; Lischka, Hans

    2011-10-20

    Absorption and fluorescence spectra of PRODAN (6-propionyl-2-dimethylaminonaphthalene) were studied by means of the time-dependent density functional theory and the algebraic diagrammatic construction method. The influence of environment, a phosphatidylcholine lipid bilayer and water, was taken into account employing a combination of quantum chemical calculations with empirical force-field molecular dynamics simulations. Additionally, experimental absorption and emission spectra of PRODAN were measured in cyclohexane, water, and lipid vesicles. Both planar and twisted configurations of the first excited state of PRODAN were taken into account. The twisted structure is stabilized in both water and a lipid bilayer, and should be considered as an emitting state in polar environments. Orientation of the excited dye in the lipid bilayer significantly depends on configuration. In the bilayer, the fluorescence spectrum can be regarded as a combination of emission from both planar and twisted structures.

  18. Absolute excited-state absorption cross section and fluorescence quantum efficiency of Cr/sup 3 +/: gadolinium scandium gallium garnet

    SciTech Connect

    Seelert, W.; Strauss, E.

    1987-10-01

    Excited-state properties of the laser material Cr/sup 3 +/:Gd/sub 3/Sc/sub 2/(GaO/sub 4/)/sub 3/ were determined by a photocaloric technique. The excited-state absorption cross section at 650 nm is (3.6 +- 0.6)10/sup -20/ cm/sup 2/, and the fluorescence quantum efficiency at ambient temperature is (91 +- 1)%.

  19. Excitation energy dependence of excited states dynamics in all- trans-carotenes determined by femtosecond absorption and fluorescence spectroscopy

    NASA Astrophysics Data System (ADS)

    Kosumi, Daisuke; Yanagi, Kazuhiro; Nishio, Tomohiro; Hashimoto, Hideki; Yoshizawa, Masayuki

    2005-06-01

    Ultrafast relaxation kinetics in β-carotene and lycopene has been investigated by femtosecond absorption and fluorescence spectroscopies using tunable excitation pulses. The transient signals induced by the photoexcitation with larger excess energy have broader bands and longer lifetimes both in the 11Bu+and21Ag- excited states. The excess vibrational energy remains longer than several picoseconds and slows the relaxation kinetics in carotenoids.

  20. Study on the interaction between fluoroquinolones and erythrosine by absorption, fluorescence and resonance Rayleigh scattering spectra and their application

    NASA Astrophysics Data System (ADS)

    Wang, Jian; Liu, Zhongfang; Liu, Jiangtao; Liu, Shaopu; Shen, Wei

    2008-03-01

    In pH 4.4-4.5 Britton-Robinson (BR) buffer solution, fluoroquinolone antibiotics (FLQs) including ciprofloxacin (CIP), norfloxacin (NOR), levofloxacin (LEV) and lomefloxacin (LOM) could react with erythrosine (Ery) to form 1:1 ion-association complexes, which not only resulted in the changes of the absorption spectra and the quenching of fluorescence, but also resulted in the great enhancement of resonance Rayleigh scattering (RRS). These offered some indications of the determination of fluoroquinolone antibiotics by spectrophotometric, fluorescence and resonance Rayleigh scattering methods. The detection limits for fluoroquinolone antibiotics were in the range of 0.097-0.265 μg/mL for absorption methods, 0.022-0.100 μg/mL for fluorophotometry and 0.014-0.027 μg/mL for RRS method, respectively. Among them, the RRS method had the highest sensitivity. In this work, the spectral characteristics of the absorption, fluorescence and RRS, the optimum conditions of the reactions and the properties of the analytical chemistry were investigated. The methods have been successfully applied to determination of some fluoroquinolone antibiotics in human urine samples and tablets. Taking CIP-Ery system as an example, the charge distribution, the enthalpy of formation and the mean polarizability were calculated by density function theory (DFT) method. In addition, the reasons for the enhancement of scattering spectra were discussed.

  1. Time-resolved spectroscopic fluorescence imaging, transient absorption and vibrational spectroscopy of intact and photo-inhibited photosynthetic tissue.

    PubMed

    Lukins, Philip B; Rehman, Shakil; Stevens, Gregory B; George, Doaa

    2005-01-01

    Fluorescence, absorption and vibrational spectroscopic techniques were used to study spinach at the photosystem II (PS II), chloroplast and cellular levels and to determine the effects and mechanisms of ultraviolet-B (UV-B) photoinhibition of these structures. Two-photon fluorescence spectroscopic imaging of intact chloroplasts shows significant spatial variations in the component fluorescence spectra in the range 640-740 nm, indicating that the type and distribution of chlorophylls vary markedly with position in the chloroplast. The chlorophyll distributions and excitonic behaviour in chloroplasts and whole plant tissue were studied using picosecond time-gated fluorescence imaging, which also showed UV-induced kinetic changes that clearly indicate that UV-B induces both structural and excitonic uncoupling of chlorophylls within the light-harvesting complexes. Transient absorption measurements and low-frequency infrared and Raman spectroscopy show that the predominant sites of UV-B damage in PS II are at the oxygen-evolving centre (OEC) itself, as well as at specific locations near the OEC-binding sites.

  2. Simultaneous determination of cadmium and lead in wine by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Freschi, Gian P. G.; Dakuzaku, Carolina S.; de Moraes, Mercedes; Nóbrega, Joaquim A.; Gomes Neto, José A.

    2001-10-01

    A method has been developed for the direct simultaneous determination of Cd and Pb in white and red wine by electrothermal atomic absorption spectrometry (ET-AAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of both analytes during pyrolysis and atomization stages were investigated in 0.028 mol l -1 HNO 3 and in 1+1 v/v diluted wine using mixtures of Pd(NO 3) 2+Mg(NO 3) 2 and NH 4H 2PO 4+Mg(NO 3) 2 as chemical modifiers. With 5 μg Pd+3 μg Mg as the modifiers and a two-step pyrolysis (10 s at 400°C and 10 s at 600°C), the formation of carbonaceous residues inside the atomizer was avoided. For 20 μl of sample (wine+0.056 mol l -1 HNO 3, 1+1, v/v) dispensed into the graphite tube, analytical curves in the 0.10-1.0 μg l -1 Cd and 5.0-50 μg l -1 Pb ranges were established. The characteristic mass was approximately 0.6 pg for Cd and 33 pg for Pb, and the lifetime of the tube was approximately 400 firings. The limits of detection (LOD) based on integrated absorbance (0.03 μg l -1 for Cd, 0.8 μg l -1 for Pb) exceeded the requirements of Brazilian Food Regulations (decree #55871 from Health Department), which establish the maximum permissible level for Cd at 200 μg l -1 and for Pb at 500 μg l -1. The relative standard deviations ( n=12) were typically <8% for Cd and <6% for Pb. The recoveries of Cd and Pb added to wine samples varied from 88 to 107% and 93 to 103%, respectively. The accuracy of the direct determination of Cd and Pb was checked for 10 table wines by comparing the results with those obtained for digested wine using single-element ET-AAS, which were in agreement at the 95% confidence level.

  3. Correlation between the Gas Temperature and the Atomization Behavior of Analyte Elements in Flame Atomic Absorption Spectrometry Estimated with a Continuum-light-source Spectrometer System

    NASA Astrophysics Data System (ADS)

    Toya, Yusuke; Itagaki, Toshiko; Wagatsuma, Kazuaki

    2016-11-01

    In flame atomic absorption spectrometry (FAAS), the gas temperature for two types of the gas compositions, which was estimated based on a two-line method by using a simultaneous multi-wavelength spectrometer, on which a line pair of ruthenium, Ru I 372.692 nm and Ru I 372.803 nm having different excitation energies, was measured at the same time. Also using the spectrometer system, the absorption signals of both iron and ruthenium, whose oxides had different thermodynamic properties: the latter oxide was decomposed much more easily than the former one, were investigated with a nitrous oxide - acetylene flame, in comparison with an air - acetylene flame. The fuel/oxidant ratio of both the flames as well as the height of the optical path was varied as an experimental parameter. The atomization behavior of iron and ruthenium, which could be deduced from a variation in their absorption signals, was considered to be dependent not only on the gas temperature but on reducing atmosphere of the flame gas, which might be attributed to reducing radicals in a fuel-excess flame consisting of nitrous oxide. In the nitrous oxide - acetylene flame, a broader optical path having a constant and higher temperature was obtained, thus contributing to formation of analyte atoms with a stable atomization efficiency and eventually to better precision in the analytical result in FAAS.

  4. High-speed atomic force microscope combined with single-molecule fluorescence microscope

    NASA Astrophysics Data System (ADS)

    Fukuda, Shingo; Uchihashi, Takayuki; Iino, Ryota; Okazaki, Yasutaka; Yoshida, Masato; Igarashi, Kiyohiko; Ando, Toshio

    2013-07-01

    High-speed atomic force microscopy (HS-AFM) and total internal reflection fluorescence microscopy (TIRFM) have mutually complementary capabilities. Here, we report techniques to combine these microscopy systems so that both microscopy capabilities can be simultaneously used in the full extent. To combine the two systems, we have developed a tip-scan type HS-AFM instrument equipped with a device by which the laser beam from the optical lever detector can track the cantilever motion in the X- and Y-directions. This stand-alone HS-AFM system is mounted on an inverted optical microscope stage with a wide-area scanner. The capability of this combined system is demonstrated by simultaneous HS-AFM/TIRFM imaging of chitinase A moving on a chitin crystalline fiber and myosin V walking on an actin filament.

  5. Velocity and electronic state distributions of sputtered Fe atoms by laser-induced fluorescence spectroscopy

    SciTech Connect

    Young, C.E.; Calaway, W.F.; Pellin, M.J.; Gruen, D.M.

    1983-01-01

    Velocity distributions and relative populations in the fine-structure levels of the a/sup 5/D/sub J/ ground state of Fe atoms, produced by sputtering with 3 keV argon ions, have been investigated by Doppler shifted laser induced fluorescence. The laser system employs a single-mode, scanning ring dye laser, amplified by a sequence of three excimer-pumped flowing-dye cells. Frequency doubling in a KD*P crystal was used to produce high energy (> .5 mJ) pulses of narrowband tunable UV output near 300 nm. Laser power influence on effective velocity bandwidth was investigated. Favorable light-collection geometry minimized distortion of the velocity spectra from apparatus-averaging effects. In impurity flux diagnostic applications in fusion devices, substantial spatial averaging may occur. In the latter case, the narrow velocity bandwidth (70 m/s, transform limit) of the present laser system is particularly useful.

  6. Sample preparation for single virion atomic force microscopy and super-resolution fluorescence imaging.

    PubMed

    Hodges, Jeffery A; Saffarian, Saveez

    2014-01-02

    Immobilization of virions to glass surfaces is a critical step in single virion imaging. Here we present a technique adopted from single molecule imaging assays which allows adhesion of single virions to glass surfaces with specificity. This preparation is based on grafting the surface of the glass with a mixture of PLL-g-PEG and PLL-g-PEG-Biotin, adding a layer of avidin, and finally creating virion anchors through attachment of biotinylated virus specific antibodies. We have applied this technique across a range of experiments including atomic force microscopy (AFM) and super-resolution fluorescence imaging. This sample preparation method results in a control adhesion of the virions to the surface.

  7. Atomic layer deposition to prevent metal transfer from implants: An X-ray fluorescence study

    NASA Astrophysics Data System (ADS)

    Bilo, Fabjola; Borgese, Laura; Prost, Josef; Rauwolf, Mirjam; Turyanskaya, Anna; Wobrauschek, Peter; Kregsamer, Peter; Streli, Christina; Pazzaglia, Ugo; Depero, Laura E.

    2015-12-01

    We show that Atomic Layer Deposition is a suitable coating technique to prevent metal diffusion from medical implants. The metal distribution in animal bone tissue with inserted bare and coated Co-Cr alloys was evaluated by means of micro X-ray fluorescence mapping. In the uncoated implant, the migration of Co and Cr particles from the bare alloy in the biological tissues is observed just after one month and the number of particles significantly increases after two months. In contrast, no metal diffusion was detected in the implant coated with TiO2. Instead, a gradient distribution of the metals was found, from the alloy surface going into the tissue. No significant change was detected after two months of aging. As expected, the thicker is the TiO2 layer, the lower is the metal migration.

  8. Determination of Te in soldering tin using continuous flowing electrochemical hydride generation atomic fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Jiang, Xianjuan; Gan, Wuer; Han, Suping; He, Youzhao

    2008-06-01

    An electrochemical hydride generation system was developed for the detection of Te by coupling an electrochemical hydride generator with atomic fluorescence spectrometry. Since TeH 2 is unstable and easily decomposes in solution, a reticular W filament cathode was used in the present system. The TeH 2 generated on the cathode surface was effectively driven out by sweeping gas from the cathode chamber. In addition, a low temperature electrochemical cell (10 °C) was applied to reduce the decomposition of TeH 2 in solution. The limit of detection (LOD) was 2.2 ng ml - 1 and the relative standard deviation (RSD) was 3.9% for nine consecutive measurements of standard solution. This method was successfully employed for determination of Te in soldering tin material.

  9. High-speed atomic force microscope combined with single-molecule fluorescence microscope.

    PubMed

    Fukuda, Shingo; Uchihashi, Takayuki; Iino, Ryota; Okazaki, Yasutaka; Yoshida, Masato; Igarashi, Kiyohiko; Ando, Toshio

    2013-07-01

    High-speed atomic force microscopy (HS-AFM) and total internal reflection fluorescence microscopy (TIRFM) have mutually complementary capabilities. Here, we report techniques to combine these microscopy systems so that both microscopy capabilities can be simultaneously used in the full extent. To combine the two systems, we have developed a tip-scan type HS-AFM instrument equipped with a device by which the laser beam from the optical lever detector can track the cantilever motion in the X- and Y-directions. This stand-alone HS-AFM system is mounted on an inverted optical microscope stage with a wide-area scanner. The capability of this combined system is demonstrated by simultaneous HS-AFM∕TIRFM imaging of chitinase A moving on a chitin crystalline fiber and myosin V walking on an actin filament.

  10. Quantification of zinc-porphyrin in dry-cured ham products by spectroscopic methods Comparison of absorption, fluorescence and X-ray fluorescence spectroscopy.

    PubMed

    Laursen, Kristoffer; Adamsen, Christina E; Laursen, Jens; Olsen, Karsten; Møller, Jens K S

    2008-03-01

    Zinc-protoporphyrin (Zn-pp), which has been identified as the major pigment in certain dry-cured meat products, was extracted with acetone/water (75%) and isolated from the following meat products: Parma ham, Iberian ham and dry-cured ham with added nitrite. The quantification of Zn-pp by electron absorption, fluorescence and X-ray fluorescence (XRF) spectroscopy was compared (concentration range used [Zn-pp]=0.8-9.7μM). All three hams were found to contain Zn-pp, and the results show no significant difference among the content of Zn-pp quantified by fluorescence, absorbance and X-ray fluorescence spectroscopy for Parma ham and Iberian ham. All three methods can be used for quantification of Zn-pp in acetone/water extracts of different ham types if the content is higher than 1.0ppm. For dry-cured ham with added nitrite, XRF was not applicable due to the low content of Zn-pp (<0.1ppm). In addition, XRF spectroscopy provides further information regarding other trace elements and can therefore be advantageous in this aspect. This study also focused on XRF determination of Fe in the extracts and as no detectable Fe was found in the three types of ham extracts investigated (limit of detection; Fe⩽1.8ppm), it allows the conclusion that iron containing pigments, e.g., heme, do not contribute to the noticeable red colour observed in some of the extracts.

  11. Determination of nickel by flame atomic-absorption spectrophotometry after separation by adsorption of its nioxime complex on microcrystalline naphthalene.

    PubMed

    Nagahiro, T; Puri, B K; Katyal, M; Satake, M

    1984-11-01

    A method has been developed for the determination of nickel in alloys by flame atomic-absorption spectrophotometry after formation of a water-insoluble complex, its adsorption on microcrystalline naphthalene, and dissolution of the complex and naphthalene in nitric acid and xylene.

  12. Identifying Student and Teacher Difficulties in Interpreting Atomic Spectra Using a Quantum Model of Emission and Absorption of Radiation

    ERIC Educational Resources Information Center

    Savall-Alemany, Francisco; Domènech-Blanco, Josep Lluís; Guisasola, Jenaro; Martínez-Torregrosa, Joaquín

    2016-01-01

    Our study sets out to identify the difficulties that high school students, teachers, and university students encounter when trying to explain atomic spectra. To do so, we identify the key concepts that any quantum model for the emission and absorption of electromagnetic radiation must include to account for the gas spectra and we then design two…

  13. Manganese dioxide causes spurious gold values in flame atomic-absorption readings from HBr-Br2 digestions

    USGS Publications Warehouse

    Campbell, W.L.

    1981-01-01

    False readings, apparently caused by the presence of high concentrations of manganese dioxide, have been observed in our current flame atomic-absorption procedure for the determination of gold. After a hydrobromic acid (HBr)-bromine (Br2) leach, simply heating the sample to boiling to remove excess Br2 prior to extraction with methyl-isobutyl-ketone (MIBK) eliminates these false readings. ?? 1981.

  14. Assessing the Engagement, Learning, and Overall Experience of Students Operating an Atomic Absorption Spectrophotometer with Remote Access Technology

    ERIC Educational Resources Information Center

    Erasmus, Daniel J.; Brewer, Sharon E.; Cinel, Bruno

    2015-01-01

    The use of internet-based technologies in the teaching of laboratories has emerged as a promising education tool. This study evaluated the effectiveness of using remote access technology to operate an atomic absorption spectrophotometer in analyzing the iron content in a crude myoglobin extract. Sixty-two students were surveyed on their level of…

  15. Overcoming Matrix Effects in a Complex Sample: Analysis of Multiple Elements in Multivitamins by Atomic Absorption Spectroscopy

    ERIC Educational Resources Information Center

    Arnold, Randy J.; Arndt, Brett; Blaser, Emilia; Blosser, Chris; Caulton, Dana; Chung, Won Sog; Fiorenza, Garrett; Heath, Wyatt; Jacobs, Alex; Kahng, Eunice; Koh, Eun; Le, Thao; Mandla, Kyle; McCory, Chelsey; Newman, Laura; Pithadia, Amit; Reckelhoff, Anna; Rheinhardt, Joseph; Skljarevski, Sonja; Stuart, Jordyn; Taylor, Cassie; Thomas, Scott; Tse, Kyle; Wall, Rachel; Warkentien, Chad

    2011-01-01

    A multivitamin tablet and liquid are analyzed for the elements calcium, magnesium, iron, zinc, copper, and manganese using atomic absorption spectrometry. Linear calibration and standard addition are used for all elements except calcium, allowing for an estimate of the matrix effects encountered for this complex sample. Sample preparation using…

  16. A Simplified Digestion Protocol for the Analysis of Hg in Fish by Cold Vapor Atomic Absorption Spectroscopy

    ERIC Educational Resources Information Center

    Kristian, Kathleen E.; Friedbauer, Scott; Kabashi, Donika; Ferencz, Kristen M.; Barajas, Jennifer C.; O'Brien, Kelly

    2015-01-01

    Analysis of mercury in fish is an interesting problem with the potential to motivate students in chemistry laboratory courses. The recommended method for mercury analysis in fish is cold vapor atomic absorption spectroscopy (CVAAS), which requires homogeneous analyte solutions, typically prepared by acid digestion. Previously published digestion…

  17. Hydrogen atom temperature measured with wavelength-modulated laser absorption spectroscopy in large scale filament arc negative hydrogen ion source

    SciTech Connect

    Nakano, H. Goto, M.; Tsumori, K.; Kisaki, M.; Ikeda, K.; Nagaoka, K.; Osakabe, M.; Takeiri, Y.; Kaneko, O.; Nishiyama, S.; Sasaki, K.

    2015-04-08

    The velocity distribution function of hydrogen atoms is one of the useful parameters to understand particle dynamics from negative hydrogen production to extraction in a negative hydrogen ion source. Hydrogen atom temperature is one of the indicators of the velocity distribution function. To find a feasibility of hydrogen atom temperature measurement in large scale filament arc negative hydrogen ion source for fusion, a model calculation of wavelength-modulated laser absorption spectroscopy of the hydrogen Balmer alpha line was performed. By utilizing a wide range tunable diode laser, we successfully obtained the hydrogen atom temperature of ∼3000 K in the vicinity of the plasma grid electrode. The hydrogen atom temperature increases as well as the arc power, and becomes constant after decreasing with the filling of hydrogen gas pressure.

  18. Inductively coupled plasma atomic fluorescence spectrometric determination of cadmium, copper, iron, lead, manganese and zinc

    USGS Publications Warehouse

    Sanzolone, R.F.

    1986-01-01

    An inductively coupled plasma atomic fluorescence spectrometric method is described for the determination of six elements in a variety of geological materials. Sixteen reference materials are analysed by this technique to demonstrate its use in geochemical exploration. Samples are decomposed with nitric, hydrofluoric and hydrochloric acids, and the residue dissolved in hydrochloric acid and diluted to volume. The elements are determined in two groups based on compatibility of instrument operating conditions and consideration of crustal abundance levels. Cadmium, Cu, Pb and Zn are determined as a group in the 50-ml sample solution under one set of instrument conditions with the use of scatter correction. Limitations of the scatter correction technique used with the fluorescence instrument are discussed. Iron and Mn are determined together using another set of instrumental conditions on a 1-50 dilution of the sample solution without the use of scatter correction. The ranges of concentration (??g g-1) of these elements in the sample that can be determined are: Cd, 0.3-500; Cu, 0.4-500; Fe, 85-250 000; Mn, 45-100 000; Pb, 5-10 000; and Zn, 0.4-300. The precision of the method is usually less than 5% relative standard deviation (RSD) over a wide concentration range and acceptable accuracy is shown by the agreement between values obtained and those recommended for the reference materials.

  19. Re-Analysis of the Dispersed Fluorescence Spectra of the C_3-RARE Gas Atom Complexes

    NASA Astrophysics Data System (ADS)

    Wang, Yi-Jen; Merer, Anthony; Hsu, Yen-Chu

    2015-06-01

    The dispersed fluorescence (DF) spectra of the C_3Ne, C_3Ar, C_3Kr, and C_3Xe complexes near the 0 2^- 0- 000, 0 4^- 0- 000, 0 2^+ 0- 000 and 100-000 bands of the {A}- {X} system of C_3 have been revisited. Some of the DF spectra of the Ne and Ar complexes have been recently obtained with a slightly improved resolution of 6-10 wn. All the DF spectra have been reassigned as emission from van der Waals (vdW) complexes and C_3 fragments. The optically excited C_3-Rg (Rg = rare-gas atom) complexes fluorescence and/or decay down to slightly lower (about 2-30 wn) vibrational levels without changing the internal energy of C_3 and then predissociate via the continua of the nearby vibronic states of C_3. The available dissociation channels depend on the binding energy of the ground electronic state complex. Exceptions have been found at the vdW bands near the 0 4^- 0- 000 band of C_3. The binding energies of the ground electronic states of these four complexes will be discussed. G. Zhang, B.-G. Lin, S.-M. Wen, and Y.-C. Hsu, J. Chem. Phys. 20, 3189(2004) J.-M. Chao, K. S. Tham, G. Zhang, A. J. Merer, Y.-C. Hsu, and W.-P. Hu, J. Chem. Phys. 34, 074313(2011)

  20. Revealing the topography of cellular membrane domains by combined atomic force microscopy/fluorescence imaging.

    PubMed

    Frankel, D J; Pfeiffer, J R; Surviladze, Z; Johnson, A E; Oliver, J M; Wilson, B S; Burns, A R

    2006-04-01

    Simultaneous atomic force microscopy (AFM) and confocal fluorescence imaging were used to observe in aqueous buffer the three-dimensional landscape of the inner surface of membrane sheets stripped from fixed tumor mast cells. The AFM images reveal prominent, irregularly shaped raised domains that label with fluorescent markers for both resting and activated immunoglobin E receptors (FcepsilonRI), as well as with cholera toxin-aggregated GM1 and clathrin. The latter suggests that coated pits bud from these regions. These features are interspersed with flatter regions of membrane and are frequently surrounded and interconnected by cytoskeletal assemblies. The raised domains shrink in height by approximately 50% when cholesterol is extracted with methyl-beta-cyclodextrin. Based on composition, the raised domains seen by AFM correspond to the cholesterol-enriched dark patches observed in transmission electron microscopy (TEM). These patches were previously identified as sites of signaling and endocytosis based on their localization of activated FcepsilonRI, at least 10 associated signaling molecules, and the presence of clathrin-coated pits. Overall the data suggest that signaling and endocytosis occur in mast cells from raised membrane regions that depend on cholesterol for their integrity and may be organized in specific relationship with the cortical cytoskeleton.

  1. Atomic Absorption Spectrometry Analysis of Trace Elements in Degenerated Intervertebral Disc Tissue

    PubMed Central

    Kubaszewski, Łukasz; Zioła-Frankowska, Anetta; Frankowski, Marcin; Nowakowski, Andrzej; Czabak-Garbacz, Róża; Kaczmarczyk, Jacek; Gasik, Robert

    2014-01-01

    Background Few studies have investigated trace elements (TE) in human intervertebral disc (IVD) tissue. Trace element presence can have diverse meanings: essential TE show the metabolic modalities of the tissue, while environmentally-related TE indicate pollution and tissue-specific absorption and accumulation. IVD is a highly specific compartment with impaired communication with adjacent bone. Analysis of TE in IVD provides new insights regarding tissue metabolism and IVD communication with other tissues. Material/Methods Thirty intervertebral discs were acquired from 22 patients during surgical treatment for degenerative disease. Atomic absorption spectrometry was used to evaluate the concentrations of Al, Cd, Pb, Cu, Ni, Mo, Mg, and Zn. Results Al, Pb, Cu, Mg, and Zn were detected in all samples. Pb was significantly positively correlated with age, and Ni concentration was weakly correlated with population count in the patient’s place of residence. Only Cu was observed in higher concentrations in IVD compared to in other tissues. Significant positive correlations were observed between the following pairs: Mg/Zn, Mg/Al, Mg/Pb, Zn/Al, Zn/Pb, and Al/Pb. Negative correlations were observed between Mg/Cd, Zn/Cd, Mg/Mo, and Mo/Pb. Conclusions This study is one of few to profile the elements in intervertebral discs in patients with degenerative changes. We report significant differences between trace element concentrations in intervertebral discs compared to in other tissues. Knowledge of the TE accumulation pattern is vital for better understanding intervertebral disc nutrition and metabolism. PMID:25366266

  2. Mapping atomic and diffuse interstellar band absorption across the Magellanic Clouds and the Milky Way

    NASA Astrophysics Data System (ADS)

    Bailey, Mandy; van Loon, Jacco Th.; Sarre, Peter J.; Beckman, John E.

    2015-12-01

    Diffuse interstellar bands (DIBs) trace warm neutral and weakly ionized diffuse interstellar medium (ISM). Here we present a dedicated, high signal-to-noise spectroscopic survey of two of the strongest DIBs, at 5780 and 5797 Å, in optical spectra of 666 early-type stars in the Small and Large Magellanic Clouds, along with measurements of the atomic Na I D and Ca II K lines. The resulting maps show for the first time the distribution of DIB carriers across large swathes of galaxies, as well as the foreground Milky Way ISM. We confirm the association of the 5797 Å DIB with neutral gas, and the 5780 Å DIB with more translucent gas, generally tracing the star-forming regions within the Magellanic Clouds. Likewise, the Na I D line traces the denser ISM whereas the Ca II K line traces the more diffuse, warmer gas. The Ca II K line has an additional component at ˜200-220 km s-1 seen towards both Magellanic Clouds; this may be associated with a pan-Magellanic halo. Both the atomic lines and DIBs show sub-pc-scale structure in the Galactic foreground absorption; the 5780 and 5797 Å DIBs show very little correlation on these small scales, as do the Ca II K and Na I D lines. This suggests that good correlations between the 5780 and 5797 Å DIBs, or between Ca II K and Na I D, arise from the superposition of multiple interstellar structures. Similarity in behaviour between DIBs and Na I in the Small Magellanic Cloud (SMC), Large Magellanic Cloud (LMC) and Milky Way suggests the abundance of DIB carriers scales in proportion to metallicity.

  3. High purity polyimide analysis by solid sampling graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Santos, Rafael F.; Carvalho, Gabriel S.; Duarte, Fabio A.; Bolzan, Rodrigo C.; Flores, Erico M. M.

    2017-03-01

    In this work, Cr, Cu, Mn, Na and Ni were determined in high purity polyimides (99.5%) by solid sampling graphite furnace atomic absorption spectrometry (SS-GFAAS) using Zeeman effect background correction system with variable magnetic field, making possible the simultaneous measurement at high or low sensitivity. The following analytical parameters were evaluated: pyrolysis and atomization temperatures, feasibility of calibration with aqueous solution, linear calibration range, sample mass range and the use of chemical modifier. Calibration with aqueous standard solutions was feasible for all analytes. No under or overestimated results were observed and up to 10 mg sample could be introduced on the platform for the determination of Cr, Cu, Mn, Na and Ni. The relative standard deviation ranged from 3 to 20%. The limits of detection (LODs) achieved using the high sensitivity mode were as low as 7.0, 2.5, 1.7, 17 and 0.12 ng g- 1 for Cr, Cu, Mn, Na and Ni, respectively. No addition of chemical modifier was necessary, except for Mn determination where Pd was required. The accuracy was evaluated by analyte spike and by comparison of the results with those obtained by inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry after microwave-assisted digestion in a single reaction chamber system and also by neutron activation analysis. No difference among the results obtained by SS-GFAAS and those obtained by alternative analytical methods using independent techniques. SS-GFAAS method showed some advantages, such as the determination of metallic contaminants in high purity polyimides with practically no sample preparation, very low LODs, calibration with aqueous standards and determination in a wide range of concentration.

  4. Mesoporous Silica Nanoparticles as an Adsorbent for Preconcentration and Determination of Trace Amount of Nickel in Environmental Samples by Atom Trap Flame Atomic Absorption Spectrometry

    NASA Astrophysics Data System (ADS)

    Shirkhanloo, H.; Falahnejad, M.; Zavvar Mousavi, H.

    2016-01-01

    A rapid enrichment method based on solid-phase extraction (SPE) has been established for preconcentration and separation of trace Ni(II) ions in water samples prior to their determination by atom trap flame atomic absorption spectrometry. A column filled with bulky NH2-UVM7 was used as the novel adsorbent. Under optimal conditions, the linear range, limit of detection (LOD), and preconcentration factor (PF) were 3-92 μg/L, 0.8 μg/L, and 100, respectively. The validity of the method was checked by the standard reference material.

  5. Role of a binary metallic modifier in the determination of cadmium in graphite furnace atomic absorption spectrometry.

    PubMed

    Morimoto, Syun; Ashino, Tetsuya; Wagatsuma, Kazuaki

    2010-01-01

    In order to discuss the matrix modifier effect of palladium, iron, and a mixture of palladium and iron for the determination of cadmium in graphite-furnace atomic absorption spectrometry (GF-AAS), we measured the absorption profiles of a cadmium line at various compositions of these elements. Variations in the gas temperature were also estimated with the progress of atomization, by using a two-line method under the assumption of a Boltzmann distribution. The atomic absorption of cadmium appeared on the way of heating from the charring temperature to the atomizing temperature while the gas temperature was still low; it was thus considered that cadmium was atomized through direct conductive heating from the wall of the graphite furnace. Therefore, the effectiveness of modifiers for cadmium would be determined through any reactions on the furnace wall at the programmed charring and atomizing temperatures. The addition of iron, palladium, and an iron-palladium mixture all enhanced the absorption signal of cadmium compared to a pure cadmium sample; however, their effects were different from one another. Each addition of iron or palladium to the sample solution led to an enhancement of the cadmium absorbance, indicating that iron or palladium individually became an effective matrix modifier for the determination of cadmium. However, the addition of palladium was ineffective for the matrix modification in the coexistence of large amounts of iron. Although these phenomena are very complicated, and thus cannot be understood completely, any metallurgical reaction between the constituent elements during heating of the furnace wall, such as the formation of solid solutions and intermetallic compounds, would cause the effect of a matrix modifier in GF-AAS.

  6. Effects of Solution Physical Properties on Copper and Chromium Signals in Flame Atomic Absorption Spectrometry

    NASA Astrophysics Data System (ADS)

    Rocha, Fàbio R. P.; Nòbrega, Joaquim A.

    1996-10-01

    Instrumental techniques, such as flame atomic absorption spectrometry (FAAS), are frequently used in chemical analysis. Independently of the technique used, the chemical principles must be considered to assure that the analytical results are correct. In FAAS, the most critical step is the sample introduction, since solutions need to be converted in an aerosol (nebulization process) that should contain drops with suitable size to attain the flame. Solution physical properties, such as viscosity and surface tension, can severely affect the analytical signals. Solutions with high viscosity are less easily aspirated and the analyte mass that reach the flame is reduced. The surface tension of the solution affects the size of the drops generated by the nebulization process and can modify the quantity of analyte that attain the flame. This work describes an experiment that allow demonstrating the effects of viscosity and surface tension on analytical signals, using a set of copper solutions prepared in different concentrations of ethanol and chromium solutions prepared in surfactant (tetrapropylammonium bromide) medium. The experiment can be carried out in a 4 h laboratory class and is useful to demonstrate to undergraduate students the effects of samples physical properties on the analytical signals in FAAS.

  7. Liquid phase microextraction and ultratrace determination of cadmium by modified graphite furnace atomic absorption spectrometry.

    PubMed

    Nazari, Saeid

    2009-06-15

    A powerful microextraction technique was used for determination of cadmium in water samples using liquid phase microextraction (LPME) followed by graphite furnace atomic absorption spectrometry (GF-AAS). In a preconcentration step, cadmium was extracted from a 2 ml of its aqueous sample in the pH 7 as 5,7-dibromoquinoline-8-ol (DBQ) complex into a 4 microl drop of benzyl alcohol. After extraction, the micro drop was retracted and directly transferred into a graphite tube modified by [W.Rh.Pd](c). Some effective parameters on extraction and complex formation, such as type and volume of organic solvent, pH, concentration of chelating agent, extraction time and stirring rate were optimized. Under the optimum conditions, the enrichment factor and recovery were 450% and 90%, respectively. The calibration graph was linear in the range of 0.008-1 microg L(-1) with correlation coefficient of 0.9961 under the optimum conditions of the recommended procedure. The detection limit based on the 3Sb criterion was 0.0035 microg L(-1) and relative standard deviation (RSD) for eight replicate measurement of 0.1 microg L(-1) and 0.4 microg L(-1) cadmium was 5.2% and 4.5%, respectively. The characteristic concentration was 0.0032 microg L(-1) equivalent to a characteristic mass of 12.8 fg. In order to evaluate the accuracy and recovery of the presented method the procedure was applied to the analysis of reference materials and seawater.

  8. Stability of low concentration calibration standards for graphite furnace atomic absorption spectrophotometry

    SciTech Connect

    Bass, D A; TenKate, L B

    1993-11-01

    Graphite furnace atomic absorption spectrophotometry (GFAAS) is used for determination of ultra-trace metals in environmentally important samples. In the generation of GFAAS calibration curves for many environmental applications, low concentration calibration standards must be prepared dally, as required by the Statement of Work (SOW) for the US Environmental Protection Agency (EPA) Contract Laboratory Program (CLP). This results in significant time and work for the analyst and significant cost to the Analytical Chemistry Laboratory (ACL) for chemicals and waste management. While EPA SW 846 is less prescriptive than the CLP SOW, ACL has been following the CLP guidelines because in-house criteria regarding the stability of GFAAS standards have not been established. A study was conducted to determine the stability of GFAAS standards for analytes commonly used in the ACL (single and mixed) as a function of time. Data were collected over nine months. The results show that GFAAS standards for Sb, Pb, Se, Ag, and TI are stable for a longer period of time than currently assumed by the CLP SOW. Reducing the frequency of preparing these standards will increase efficiency, decrease the handling of hazardous the quantity of hazardous waste generated, and decrease the quantity of hazardous substances to be ordered and stocked by the laboratory. These benefits will improve GFAAS analysis quality, reduce costs, enhance safety, and lower environmental concerns.

  9. Determination of toxic metals in some herbal drugs through atomic absorption spectroscopy.

    PubMed

    Hina, Bushra; Rizwani, Ghazala Hafeez; Naseem, Shahid

    2011-07-01

    This study presents a picture of occurrence of heavy metals (Pb, Cd, Cu, Cr, Co, Fe, Ni, Zn) in some selected valuable herbal drugs (G. glabra, O. bracteatum, V. odorata , F. vulgare, C. cyminum, C. sativum, and Z. officinalis) purchased from three different zones (southern, eastern, and western) of Karachi city using atomic absorption spectrophotometer. Heavy metal concentrations in these drugs were found in the range of: 3.26-30.46 for Pb, 1.6-4.91 for Cd, 0.65-120.21 for Cu, 83.74-433.76 for Zn, 1.61-186.75 for Cr, 0.48-76.97 for Ni, 5.54-77.97 for Co and 65.68-1652.89 µg/g for Fe. Percentage of heavy metals that were found beyond the permissible limits were: 71.4% for Pb, 28.51% for Cd, 14.2% for Cu, and 9.5 % for Cr. Significant difference was noticed for each heavy metal among herbal drugs as well as their zones of collection using two way ANOVA followed by least significant (LSD) test at p<0.05.Purpose of this research is to detect each type of heavy metal contaminant of herbal drugs by environmental pollution, as well as to highlight the health risks associated with the use of such herbal drugs that contain high levels of toxic heavy metals.

  10. Germanium determination by flame atomic absorption spectrometry: an increased vapor pressure-chloride generation system.

    PubMed

    Kaya, Murat; Volkan, Mürvet

    2011-03-15

    A new chloride generation system was designed for the direct, sensitive, rapid and accurate determination of the total germanium in complex matrices. It was aimed to improve the detection limit of chloride generation technique by increasing the vapor pressure of germanium tetrachloride (GeCl(4)). In order to do so, a novel joint vapor production and gas-liquid separation unit equipped with a home-made oven was incorporated to an ordinary nitrous oxide-acetylene flame atomic absorption spectrometer. Several variables such as reaction time, temperature and acid concentration have been investigated. The linear range for germanium determination was 0.1-10 ng mL(-1) for 1 mL sampling volume with a detection limit (3s) of 0.01 ng mL(-1). The relative standard deviation (RSD) was 2.4% for nine replicates of a 1 ng mL(-1) germanium solution. The method was validated by the analysis of one non-certified and two certified geochemical reference materials, respectively, CRM GSJ-JR-2 (Rhyolite), and GSJ-JR-1 (Rhyolite), and GBW 07107 (Chinese Rock). Selectivity of the method was investigated for Cd(2+), Co(2+), Cu(2+), Fe(3+), Ga(3+), Hg(2+), Ni(2+), Pb(2+), Sn(2+), and Zn(2+) ions and ionic species of As(III), Sb(III), Te(IV), and Se(IV).

  11. Speciation of methylmercury in market seafood by thermal degradation, amalgamation and atomic absorption spectroscopy.

    PubMed

    Ruiz-de-Cenzano, Manuela; Rochina-Marco, Arancha; Cervera, M Luisa; de la Guardia, Miguel

    2014-09-01

    Sample thermal decomposition followed by mercury amalgamation and atomic absorption has been employed for the determination of methylmercury (MeHg) in fish. The method involves HBr leaching of MeHg, extraction into toluene, and back-extraction into an aqueous l-cysteine solution. Preliminary studies were focused on the extraction efficiency, losses, contaminations, and species interconversion prevention. The limit of detection was 0.018µgg(-1) (dry weight). The intraday precision for three replicate analysis at a concentration of 4.2µgg(-1) (dry weight) was 3.5 percent, similar to the interday precision according to analysis of variance (ANOVA). The accuracy was guaranteed by the use of fortified samples involving 83-105 percent recoveries, and certified reference materials TORT-2 (lobster hepatopancreas) and DORM-3 (dogfish liver), providing 107 and 98 percent recovery of certified values. The greenness of the method was also evaluated with the analytical eco-scale being obtained a final score of 73 points which means an acceptable green analysis. The method was applied to fifty-seven market samples of different fish acquired from local markets in several sampling campaigns. The content of MeHg found varied between 0.0311 and 1.24µgg(-1) (wet weight), with values that involve 33-129 percent of the total mercury content. Some considerations about food safety were also done taking into account data about Spanish fish consume and Tolerable Weekly Intake (TWI) established for MeHg.

  12. Atomic absorption spectrometric determination of copper, zinc, and lead in geological materials

    USGS Publications Warehouse

    Sanzolone, R.F.; Chao, T.T.

    1976-01-01

    An atomic absorption spectrometric method is described for the determination of copper, zinc, and lead in geological materials. The sample is digested with HF-HCl-H2O2; the final solution for analysis is in 10 % (v/v) HCl. Copper and zinc are determined directly by aspirating the solution into an air-acetylene flame. A separate aliquot of the solution is used for determination of lead; lead is extracted into TOPO-MIBK from the acidic solution in the presence of iodide and ascorbic acid. For a 0.50-g sample, the limits of determination are 10-2000 p.p.m. for Cu and Zn, and 5-5000 p.p.m. for Pb. As much as 40 % Fe or Ca. and 10 % Al, Mg, or Mn in the sample do not interfere. The proposed method can be applied to the determination of copper, zinc, and lead in a wide range of geological materials including iron- and manganese-rich, calcareous and carbonate samples. ?? 1976.

  13. Monitoring of trace elements in honey from the Republic of Macedonia by atomic absorption spectrometry.

    PubMed

    Stankovska, Elena; Stafilov, Trajce; Sajn, Robert

    2008-07-01

    Contents of Zn, Cu, Fe, Mn, Cd, Na, K, Ca and Mg in 123 honey samples from different regions of the Republic of Macedonia were determined by atomic absorption spectrometry. A microwave digestion system was applied for digestion of the samples. The mean content for the elements determined was found to be: 2.252, 0.696, 1.885, 1.752, 0.004, 29.52, 984.8, 40.11, 18.24 mg kg(-1) for Zn, Cu, Fe, Mn, Cd, Na, K, Ca and Mg, respectively. Based on a comparison of statistical parameters, the spatial distribution of particular elements in Macedonian honey and the results of factor analysis, two natural and one anthropogenic geochemical associations were identified. The natural geochemical associations (Mg, Mn, Ca, K and Fe, Zn, Ca, -K, -Na) are influenced mainly by lithology. The anthropogenic associations (Cd and -Cu) are mostly a result of metallurgical activities, namely lead production in the town of Veles.

  14. [Determination of rubidium and cesium in chloride type oilfield water by flame atomic absorption spectrometry].

    PubMed

    Ye, Xiu-Shen; Zhang, Shan-Ying; Li, Hai-Jun; Li, Wu; Wu, Zhi-Jian

    2009-03-01

    Flame atomic absorption spectrometry (FAAS) was applied to the determination of rubidium and cesium in chloride type oilfield water by considering the interferences of the coexistent K+, Na+, Ca2+, and Mg2+ ions, Standard curve method and standard addition method were compared in the determination of rubidium and cesium in the simulated oilfield water and the real oilfield water from the Nanyishan region in Qaidam Basin. Although rubidium and cesium have similar physical-chemical properties, they present different characters during their analyses using the FAAS technique. When the standard addition method was used for the determination of rubidium and cesium in the simulated oilfield water, the results of rubidium were very poor, whereas the results of cesium were satisfactory. When the standard curve method was used for the determination of rubidium and cesium in the simulated oilfield water, the results of both rubidium and cesium were satisfactory within the linear ranges of the standard curves. For the real oilfield water, standard addition method is also only applicable for the determination of cesium with a recovery ranging from 90% to 110%. While standard curve method is applicable for the determination of both rubidium and cesium with a recovery ranging from 90% to 110%.

  15. Determination of Mo and V in multiphase gasoline emulsions by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Santana Sodré dos Santos, Denilson; Paixão Teixeira, Alete; das Graças Andrade Korn, Maria; Sena Gomes Teixeira, Leonardo

    2006-05-01

    This paper proposes an alternative analytical method using electrothermal atomic absorption spectrometry to determine Mo and V in multiphase gasoline emulsions. Samples were prepared by mixing gasoline with a nitric acid solution (0.1% v/v) and two cationic surfactants. The mixture was sonicated, resulting in an emulsive system. Calibration was done by using the aforementioned solutions with added analyte. The detection limits (3 σ) of Mo and V were 0.9 μg l - 1 and 4.7 μg l - 1 , respectively. The accuracy and precision of the proposed method were evaluated by the analysis of samples spiked with metallo-organic standard and the relative standard deviation obtained ranged from 1.2% to 4.4% in samples spiked with 2 μg l - 1 of each metal. The recovery rates varied from 91.2% to 101.6%. The proposed method was applied to determine Mo and V in samples of gasoline from different gas stations.

  16. Highly sensitive fiber grating chemical sensors: An effective alternative to atomic absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Laxmeshwar, Lata. S.; Jadhav, Mangesh S.; Akki, Jyoti. F.; Raikar, Prasad; Kumar, Jitendra; prakash, Om; Raikar, U. S.

    2017-06-01

    Accuracy in quantitative determination of trace elements like Zinc, present in drinking water in ppm level, is a big challenge and optical fiber gratings as chemical sensors may provide a promising solution to overcome the same. This paper presents design of two simple chemical sensors based on the principle of shift in characteristic wavelength of gratings with change in their effective refractive index, to measure the concentration of Zinc in drinking water using etched short period grating (FBG) and Long period grating (LPG) respectively. Three samples of drinking water from different places have been examined for presence of Zinc. Further, the results obtained by our sensors have also been verified with the results obtained by a standard method, Atomic absorption spectroscopy (AAS). The whole experiment has been performed by fixing the fibers in a horizontal position with the sensor regions at the center of the fibers, making it less prone to disturbance and breaking. The sensitivity of LPG sensor is about 205 times that of the FBG sensor. A few advantages of Fiber grating sensors, besides their regular features, over AAS have also been discussed, that make our sensors potential alternatives for existing techniques in determination of trace elements in drinking water.

  17. Arsenic speciation in natural water samples by coprecipitation-hydride generation atomic absorption spectrometry combination.

    PubMed

    Tuzen, Mustafa; Citak, Demirhan; Mendil, Durali; Soylak, Mustafa

    2009-04-15

    A speciation procedure for As(III) and As(V) ions in environmental samples has been presented. As(V) was quantitatively recovered on aluminum hydroxide precipitate. After oxidation of As(III) by using dilute KMnO(4), the developed coprecipitation was applied to determination of total arsenic. Arsenic(III) was calculated as the difference between the total arsenic content and As(V) content. The determination of arsenic levels was performed by hydride generation atomic absorption spectrometry (HG-AAS). The analytical conditions for the quantitative recoveries of As(V) including pH, amount of aluminum as carrier element and sample volume, etc. on the presented coprecipitation system were investigated. The effects of some alkaline, earth alkaline, metal ions and also some anions were also examined. Preconcentration factor was calculated as 25. The detection limits (LOD) based on three times sigma of the blank (N: 21) for As(V) was 0.012 microg L(-1). The satisfactory results for the analysis of arsenic in NIST SRM 2711 Montana soil and LGC 6010 Hard drinking water certified reference materials for the validation of the method was obtained. The presented procedure was successfully applied to real samples including natural waters for arsenic speciation.

  18. Column preconcentration and electrothermal atomic absorption spectrometric determination of rhodium in some food and standard samples.

    PubMed

    Taher, Mohammad Ali; Pourmohammad, Fatemeh; Fazelirad, Hamid

    2015-12-01

    In the present work, an electrothermal atomic absorption spectrometric method has been developed for the determination of ultra-trace amounts of rhodium after adsorption of its 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol/tetraphenylborate ion associated complex at the surface of alumina. Several factors affecting the extraction efficiency such as the pH, type of eluent, sample and eluent flow rates, sorption capacity of alumina and sample volume were investigated and optimized. The relative standard deviation for eight measurements of 0.1 ng/mL of rhodium was ±6.3%. In this method, the detection limit was 0.003 ng/mL in the original solution. The sorption capacity of alumina and the linear range for Rh(III) were evaluated as 0.8 mg/g and 0.015-0.45 ng/mL in the original solution, respectively. The proposed method was successfully applied for the extraction and determination of rhodium content in some food and standard samples with high recovery values.

  19. Determination of total gaseous lead in the atmosphere by honeycomb denuder/electrothermal atomic absorption spectrometry.

    PubMed

    Zhang, Bicheng; Wu, Tao; Yu, Jimmy C

    2005-09-01

    A technique is described for the determination of total gaseous lead in the atmosphere by honeycomb denuder collection, followed by an electrothermal atomic absorption spectrometry (ETAAS) measurement. The collection efficiency of the honeycomb denuder in which a solution containing 2% HNO3/2% glycerine/1% ammonium dihydrogenphosphate was coated for trapping the gaseous lead in the atmosphere was 98.8%. The linear absorbance response was obtained for a concentration range of 0-1.39 microg m(-3) of lead in the atmosphere. A precision of 4.8% RSD (peak-height absorbance, n = 11) for an aqueous solution of 1 ng of lead standard, characteristic masses (CM) of 23 pg and detection limit (3sigma) of 54 pg for an aqueous solution of 0.01 ng lead standard was achieved with 100 microg ammonium dihydrogenphosphate as a chemical modifier. The average recovery of lead in three standard samples prepared by the independent digestion of NIST SRM 1648 (Urban Particulate Matter) using our analytical system was 97.8%. The total content of the gaseous lead in the atmosphere of our laboratories was 0.35-0.38 microg m(-3).

  20. Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry

    PubMed Central

    Zelinková, Hana; Červenka, Rostislav; Komárek, Josef

    2012-01-01

    Tetramethylene dithiocarbamate (TMDTC), diethyldithiocarbamate (DEDTC), and thiourea were investigated as stabilizing agents for calibration purposes in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS). These agents were used for complexation of mercury in calibration solutions and its thermal stabilization in a solid sampling platform. The calibration solutions had the form of methyl isobutyl ketone (MIBK) extracts or MIBK-methanol solutions with the TMDTC and DEDTC chelates and aqueous solutions with thiourea complexes. The best results were obtained for MIBK-methanol solutions in the presence of 2.5 g L−1 TMDTC. The surface of graphite platforms for solid sampling was modified with palladium or rhenium by using electrodeposition from a drop of solutions. The Re modifier is preferable due to a higher lifetime of platform coating. A new SS-ETAAS procedure using the direct sampling of solid samples into a platform with an Re modified graphite surface and the calibration against MIBK-methanol solutions in the presence of TMDTC is proposed for the determination of mercury content in solid environmental samples, such as soil and plants. PMID:22654606

  1. Determination of nickel, chromium and cobalt in wheat flour using slurry sampling electrothermal atomic absorption spectrometry.

    PubMed

    González, M; Gallego, M; Valcárcel, M

    1999-05-01

    The slurry technique was applied to the determination of Ni, Cr and Co in wheat flour by electrothermal atomic absorption spectrometry (ETAAS). The influence of the graphite furnace temperature programme was optimized. Optimum sensitivity was obtained by using a mixture of 15% HNO(3)-10% H(2)O(2) as suspended medium for a 3% w/v slurry in the determination of Ni; lower concentrations of HNO(3) were necessary for the determination of Co and Cr (viz. 5 and 10%). The precision of direct analyses of the slurries was improved by using mechanical agitation between measurements; thus, the RSD of the measurements was ca. 5% for repeatability. The direct slurry sampling (SS) technique is suitable for the determination of Ni and Cr in wheat flour samples at levels of 150-450 and 30-72 ng g(-1), respectively, as it provides results similar to those obtained by ashing the sample. However, the typically low level of Co in these samples precluded its determination by the proposed method (the study was made in an SRM spiked wholemeal flour), at least in those samples that were contaminated with elevated concentrations of the metal (viz. more than 90 ng of Co per g of flour). The method provides a relative standard deviation of 6, 8, and 4% for Ni, Cr, and Co, respectively.

  2. Atomic Structure of Pt3Ni Nanoframe Electrocatalysts by in Situ X-ray Absorption Spectroscopy.

    PubMed

    Becknell, Nigel; Kang, Yijin; Chen, Chen; Resasco, Joaquin; Kornienko, Nikolay; Guo, Jinghua; Markovic, Nenad M; Somorjai, Gabor A; Stamenkovic, Vojislav R; Yang, Peidong

    2015-12-23

    Understanding the atomic structure of a catalyst is crucial to exposing the source of its performance characteristics. It is highly unlikely that a catalyst remains the same under reaction conditions when compared to as-synthesized. Hence, the ideal experiment to study the catalyst structure should be performed in situ. Here, we use X-ray absorption spectroscopy (XAS) as an in situ technique to study Pt3Ni nanoframe particles which have been proven to be an excellent electrocatalyst for the oxygen reduction reaction (ORR). The surface characteristics of the nanoframes were probed through electrochemical hydrogen underpotential deposition and carbon monoxide electrooxidation, which showed that nanoframe surfaces with different structure exhibit varying levels of binding strength to adsorbate molecules. It is well-known that Pt-skin formation on Pt-Ni catalysts will enhance ORR activity by weakening the binding energy between the surface and adsorbates. Ex situ and in situ XAS results reveal that nanoframes which bind adsorbates more strongly have a rougher Pt surface caused by insufficient segregation of Pt to the surface and consequent Ni dissolution. In contrast, nanoframes which exhibit extremely high ORR activity simultaneously demonstrate more significant segregation of Pt over Ni-rich subsurface layers, allowing better formation of the critical Pt-skin. This work demonstrates that the high ORR activity of the Pt3Ni hollow nanoframes depends on successful formation of the Pt-skin surface structure.

  3. Improved preparation of small biological samples for mercury analysis using cold vapor atomic absorption spectroscopy.

    PubMed

    Adair, B M; Cobb, G P

    1999-05-01

    Concentrations of mercury in biological samples collected for environmental studies are often less than 0.1 microgram/g. Low mercury concentrations and small organ sizes in many wildlife species (approximately 0.1 g) increase the difficulty of mercury determination at environmentally relevant concentrations. We have developed a digestion technique to extract mercury from small (0.1 g), biological samples at these relevant concentrations. Mean recoveries (+/- standard error) from validation trials of mercury fortified tissue samples using cold vapor atomic absorption spectroscopy for analysis ranged from 102 +/- 4.3% (2.5 micrograms/L, n = 15) to 108 +/- 1.4% (25 micrograms/L, n = 15). Recoveries of inorganic mercury were 99 +/- 5 (n = 19) for quality assurance samples analyzed during environmental evaluations conducted during a 24 month period. This technique can be used to determine total mercury concentrations of 60 ng Hg/g sample. Samples can be analyzed in standard laboratories in a short time, at minimal cost. The technique is versatile and can be used to determine mercury concentrations in several different matrices, limiting the time and expense of method development and validation.

  4. Detection of Glucose with Atomic Absorption Spectroscopy by Using Oligonucleotide Functionalized Gold Nanoparticle.

    PubMed

    Zhang, Hong; Yan, Honglian; Ling, Liansheng

    2016-06-01

    A novel method for the detection of glucose was established with atomic absorption spectroscopy by using the label of gold nanoparticle (AuNP). Silver-coated glass assembled with oligonucleotide 5'-SH-T12-AGA CAA GAG AGG-3' (Oligo 1) was acted as separation probe, oligonucleotide 5'-CAA CAG AGA ACG-T12-SH-3' modified gold nanoparticle (AuNP-Oligo 2) was acted as signal-reporting probe. Oligonucleotide 5'-CGT TCT CTG TTG CCT CTC TTG TCT-3' (Oligo 3) could hybridize with Oligo 1 on the surface of silver-coated glass and AuNP-Oligo 2, and free AuNP-Oligo 2 could be removed by rinsing with buffer. Hence the concentration of Oligo 3 was transformed into the concentration of gold element. In addition, Oligo 3 could be cleaved into DNA fragments by glucose, glucose oxidase and Fe(2+)-EDTA through Fenton reaction. Thereby the concentration of glucose could be transformed to the absorbance of gold element. Under the optimum conditions, the integrated absorbance decreased proportionally to the concentration of glucose over the range from 50.0 μM to 1.0 mM with a detection limit of 40.0 μM. Moreover, satisfactory result was obtained when the assay was used to determinate glucose in human serum.

  5. Determination of firing distance. Lead analysis on the target by atomic absorption spectroscopy (AAS).

    PubMed

    Gagliano-Candela, Roberto; Colucci, Anna P; Napoli, Salvatore

    2008-03-01

    This paper reports a method for the determination of the firing distance. Atomic absorption spectroscopy (AAS) was used to determine the lead (Pb) pattern around bullet holes produced by shots on test targets from the gun. Test shots were made with a Colt 38 Special at 5, 10, 20, 25, 30, 35, 40, 45, 50, 60, 80, and 100 cm target distance. The target was created with sheets of Whatman no. 1 paper on a polystyrene support. The target was subdivided into three carefully cut out rings (1, 2, and 3; with external diameters of 1.4 cm; 5 cm; 10.2 cm, respectively). Each sample was analyzed with graphite furnace AAS. Lead values analysis performed for each ring yielded a linear relation between the firing distance (cm) and the logarithm of lead amounts (microg/cm(2)) in definite target areas (areas 2 + 3): [ln dPb(2+3) = a(0) + a(1)l]; where dPb(2+3) = lead microg/cm(2) of area 2 + 3; a(0) and a(1) are experimentally calculated; l = distance in cm.

  6. Measurement of nickel, cobalt and chromium in toy make-up by atomic absorption spectroscopy.

    PubMed

    Corazza, Monica; Baldo, Federica; Pagnoni, Antonella; Miscioscia, Roberta; Virgili, Annarosa

    2009-01-01

    Cosmetics should not contain more than 5 ppm of nickel, chromium or cobalt and, in order to minimize the risk of sensitization in very sensitive subjects, the target amount should be as low as 1 ppm. However, there are no published reports on the presence of these metals in toy make-up. This study analysed 52 toy make-ups using atomic absorption spectroscopy. More than 5 ppm of nickel was present in 14/52 (26.9%) samples. Chromium exceeded 5 ppm in 28/52 (53.8%) samples, with values over 1000 ppm in 3 eye shadows. Cobalt was present in amounts over 5 ppm in 5/52 (9.6%) samples. Powdery toy make-up (eye shadows) had the highest levels of metals, and "creamy" toy make-up (lip gloss and lipsticks) the lowest. Toy make-ups are potentially sensitizing items, especially for atopic children, who have a damaged skin barrier that may favour penetration of allergens.

  7. Determination of total tin in silicate rocks by graphite furnace atomic absorption spectrometry

    USGS Publications Warehouse

    Elsheimer, H.N.; Fries, T.L.

    1990-01-01

    A method is described for the determination of total tin in silicate rocks utilizing a graphite furnace atomic absorption spectrometer with a stabilized-temperature platform furnace and Zeeman-effect background correction. The sample is decomposed by lithium metaborate fusion (3 + 1) in graphite crucibles with the melt being dissolved in 7.5% hydrochloric acid. Tin extractions (4 + 1 or 8 + 1) are executed on portions of the acid solutions using a 4% solution of tricotylphosphine oxide in methyl isobutyl ketone (MIBK). Ascorbic acid is added as a reducing agent prior to extraction. A solution of diammonium hydrogenphosphate and magnesium nitrate is used as a matrix modifier in the graphite furnace determination. The limit of detection is > 10 pg, equivalent to > 1 ??g l-1 of tin in the MIBK solution or 0.2-0.3 ??g g-61 in the rock. The concentration range is linear between 2.5 and 500 ??g l-1 tin in solution. The precision, measured as relative standard deviation, is < 20% at the 2.5 ??g l-1 level and < 7% at the 10-30 ??g l-1 level of tin. Excellent agreement with recommended literature values was found when the method was applied to the international silicate rock standards BCR-1, PCC-1, GSP-1, AGV-1, STM-1, JGb-1 and Mica-Fe. Application was made to the determination of tin in geological core samples with total tin concentrations of the order of 1 ??g g-1 or less.

  8. [Determination of trace elements in new food sources by flame atomic absorption spectrophotometry].

    PubMed

    Liu, Li E; Ding, Li; Qi, Min; Han, Xiu Li; Zhang, Hong-Quan

    2007-07-01

    Samples were digested by HNO3 + HClO4. Flame atomic absorption spectrophotometry (FAAS) was successfully used to determine copper, zinc and iron in new resource food. Under our experimental conditions, the recovery ratio was 94.66%-108.80%; the precision was 0.71%-4.78%. This method of measuring elements is convenient, rapid and accurate. The results showed that there are profitable elements, such as copper, zinc and iron in new resourse food in Henan province. By F test and SNK test, the content sequence of metal elements was found as follows: copper, Chrysanthemum morifolium Ramat = Silkworm pupa > flowers of Pueraria lobata Ohwin = Wheat germ = Codonopsis lanceolata = roots of Pueraria lobata Ohwi > Opuntia dillenii Haw. Zinc, Opuntia dillenii Haw > Silkworm pupa = flowers of Pueraria lobata Ohwi = roots of Pueraria lobata Ohwi = Wheat germ = Codonopsis lanceolata = Chrysanthemum morifolium Ramat. Iron, Silkworm pupa = C hrysanthemum morifolium Ramat = roots of Pueraria lobata Ohwi > flowers of Pueraria lobata Ohwi = Wheat germ = Codonopis lanceolata = Opuntia dillenii Haw.

  9. Determination of arsenic in a nickel alloy by flow injection hydride generation atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Hanna, C. P.; Tyson, J. F.; Offley, S. G.

    1992-08-01

    The development of a method for the direct determination of trace arsenic quantities in nickel alloy digests, by flow injection hydride generation atomic absorption spectrometry, is described. An optimization study of the manifold and chemical parameters produced system performance, in terms of tolerance of the nickel matrix and sensitivity, such that matrix removal and pre-reduction of As(V) to As (III) prior to arsine generation were eliminated. Full recovery of the As(V) signal from a solution containing 5 ng ml -1 in the presence of 60 μg ml -1 nickel was obtained. Validation of the method was achieved by analyzing a British Chemical Standard (BCS) Certified Reference Material (CRM) #346 IN nickel alloy containing arsenic at a concentration of 50 μg g -1. Following dissolution in nitric and hydrofluoric acids by a microwave assisted procedure, the only subsequent preparation required was dilution by the appropriate factor. Up to 60 injections h -1 may be made, with a detection limit of 0.5 ng ml -1 arsenic (250 pg absolute) as As(V) in a 500 μl sample. The peak height characteristic concentration is 0.46 ng ml -1, with a relative standard deviation of 3.5% for a 10 ng ml -1 As(V) standard ( n = 6).

  10. Determination of nickel in active pharmaceutical ingredients by electrothermal atomic absorption spectrometry.

    PubMed

    Bubnič, Zoran; Urleb, Uroš; Kreft, Katjuša; Veber, Marjan

    2010-03-01

    An electrothermal atomic absorption spectrometric procedure for the determination of nickel in active pharmaceutical ingredients was developed. Since the recoveries of nickel by the direct dissolution of samples in diluted nitric acid were low and caused errors in the determination of Ni in pharmaceutical samples, different approaches for sample pre-treatment were examined. It was found that the microwave digestion was the most suitable way for sample preparation. Various combinations of digestion agents and different microwave conditions were tested. The combination of nitric acid and hydrogen peroxide was found to be the most appropriate. The validity of the method was evaluated by recovery studies of spiked samples and by the comparison of the results obtained by inductively coupled plasma mass spectrometry (ICP-MS). The recovery ranged from 87.5 to 104.0% and a good agreement was achieved between both methods. The detection limit and the limit of quantification were 0.6 and 2.1 µg g-1 respectively. The precision of the method was confirmed by the determination of Ni in the spiked samples and was below 4%, expressed in terms of a relative standard deviation. The method was applied to the determination of nickel in production samples of active pharmaceutical ingredients and intermediates.

  11. Assessment of toxic metals in raw and processed milk samples using electrothermal atomic absorption spectrophotometer.

    PubMed

    Kazi, Tasneem Gul; Jalbani, Nusrat; Baig, Jameel Ahmed; Kandhro, Ghulam Abbas; Afridi, Hassan Imran; Arain, Mohammad Balal; Jamali, Mohammad Khan; Shah, Abdul Qadir

    2009-09-01

    Milk and dairy products have been recognized all over the world for their beneficial influence on human health. The levels of toxic metals (TMs) are an important component of safety and quality of milk. A simple and efficient microwave assisted extraction (MAE) method has been developed for the determination of TMs (Al, Cd, Ni and Pb), in raw and processed milk samples. A Plackett-Burman experimental design and 2(3)+star central composite design, were applied in order to determine the optimum conditions for MAE. Concentrations of TMs were measured by electrothermal atomic absorption spectrometry. The accuracy of the optimized procedure was evaluated by standard addition method and conventional wet acid digestion method (CDM), for comparative purpose. No significant differences were observed (P>0.05), when comparing the values obtained by the proposed MAE method and CDM (paired t-test). The average relative standard deviation of the MAE method varied between 4.3% and 7.6% based on analyte (n=6). The proposed method was successfully applied for the determination of understudy TMs in milk samples. The results of raw and processed milk indicated that environmental conditions and manufacturing processes play a key role in the distribution of toxic metals in raw and processed milk.

  12. Cadmium accumulation in the crayfish, Procambarus clarkii, using graphite furnace atomic absorption spectroscopy

    SciTech Connect

    Diaz-Mayans, J.; Hernandez, F.; Medina, J.; Del Ramo, J.; Torreblanca, A.

    1986-11-01

    Lake Albufera and the surrounding rice-field waters are being subject to very heavy loads of sewage and toxic industrial residues (including heavy metals and pesticides) from the many urban and wastewaters in this area. The American red crayfish Procambarus clarkii is native to the Louisiana marshes (USA). In 1978, the crayfish appeared in Lake Albufera near Valencia (Spain), and presently, without adequate sanitary controls, the crayfish is being fished commercially for human consumption. In view of this interest, it is important to have accurate information on concentrations of cadmium in natural waters and cadmium levels of tissues of freshwaters animals used as human food, as well as the accumulation rates of this metal in this animal. In the present study, the authors investigated the accumulation of cadmium in several tissues of the red crayfish, P clarkii (Girard) from Lake Albufera following cadmium exposure. Determinations of cadmium were made by flameless atomic absorption spectroscopy and the standard additions method. Digestion of samples was made by wet ashing in open flasks with concentrated HNO/sub 3/ at 80-90/sup 0/C.

  13. Depth-Resolved X-ray Absorption Spectroscopy by Means of Grazing Emission X-ray Fluorescence.

    PubMed

    Kayser, Yves; Sá, Jacinto; Szlachetko, Jakub

    2015-11-03

    Grazing emission X-ray fluorescence (GEXRF) is well suited for nondestructive elemental-sensitive depth-profiling measurements on samples with nanometer-sized features. By varying the grazing emission angle under which the X-ray fluorescence signal is detected, the probed depth range can be tuned from a few to several hundred nanometers. The dependence of the XRF intensity on the grazing emission angle can be assessed in a sequence of measurements or in a scanning-free approach using a position-sensitive area detector. Hereafter, we will show that the combination of scanning-free GEXRF and fluorescence detected X-ray absorption spectroscopy (XAS) allows for depth-resolved chemical speciation measurements with nanometer-scale accuracy. While the conventional grazing emission geometry is advantageous to minimize self-absorption effects, the use of a scanning-free setup makes the sequential scanning of the grazing emission angles obsolete and paves the way toward time-resolved depth-sensitive XAS measurements. The presented experimental approach was applied to study the surface oxidation of an Fe layer on the top of bulk Si and of a Ge bulk sample. Thanks to the penetrating properties and the insensitivity toward the electric conduction properties of the incident and emitted X-rays, the presented experimental approach is well suited for in situ sample surface studies in the nanometer regime.

  14. Attosecond transient absorption of argon atoms in the vacuum ultraviolet region: line energy shifts versus coherent population transfer

    NASA Astrophysics Data System (ADS)

    Cao, Wei; Warrick, Erika R.; Neumark, Daniel M.; Leone, Stephen R.

    2016-01-01

    Using attosecond transient absorption, the dipole response of an argon atom in the vacuum ultraviolet (VUV) region is studied when an external electromagnetic field is present. An isolated attosecond VUV pulse populates Rydberg states lying 15 eV above the argon ground state. A synchronized few-cycle near infrared (NIR) pulse modifies the oscillating dipoles of argon impulsively, leading to alterations in the VUV absorption spectra. As the NIR pulse is delayed with respect to the VUV pulse, multiple features in the absorption profile emerge simultaneously including line broadening, sideband structure, sub-cycle fast modulations, and 5-10 fs slow modulations. These features indicate the coexistence of two general processes of the light-matter interaction: the energy shift of individual atomic levels and coherent population transfer between atomic eigenstates, revealing coherent superpositions. An intuitive formula is derived to treat both effects in a unifying framework, allowing one to identify and quantify the two processes in a single absorption spectrogram.

  15. Absolute number densities of helium metastable atoms determined by atomic absorption spectroscopy in helium plasma-based discharges used as ambient desorption/ionization sources for mass spectrometry

    NASA Astrophysics Data System (ADS)

    Reininger, Charlotte; Woodfield, Kellie; Keelor, Joel D.; Kaylor, Adam; Fernández, Facundo M.; Farnsworth, Paul B.

    2014-10-01

    The absolute number densities of helium atoms in the 2s 3S1 metastable state were determined in four plasma-based ambient desorption/ionization sources by atomic absorption spectroscopy. The plasmas included a high-frequency dielectric barrier discharge (HF-DBD), a low temperature plasma (LTP), and two atmospheric-pressure glow discharges, one with AC excitation and the other with DC excitation. Peak densities in the luminous plumes downstream from the discharge capillaries of the HF-DBD and the LTP were 1.39 × 1012 cm- 3 and 0.011 × 1012 cm- 3, respectively. Neither glow discharge produced a visible afterglow, and no metastable atoms were detected downstream from the capillary exits. However, densities of 0.58 × 1012 cm- 3 and 0.97 × 1012 cm- 3 were measured in the interelectrode regions of the AC and DC glow discharges, respectively. Time-resolved measurements of metastable atom densities revealed significant random variations in the timing of pulsed absorption signals with respect to the voltage waveforms applied to the discharges.

  16. Temperature-controlled electrothermal atomization-atomic absorption spectrometry using a pyrometric feedback system in conjunction with a background monitoring device

    NASA Astrophysics Data System (ADS)

    Van Deijck, W.; Roelofsen, A. M.; Pieters, H. J.; Herber, R. F. M.

    The construction of a temperature-controlled feedback system for electrothermal atomization-atomic absorption spectrometry (ETA-AAS) using an optical pyrometer applied to the atomization stage is described. The system was used in conjunction with a fast-response background monitoring device. The heating rate of the furnace amounted to 1400° s -1 with a reproducibility better than 1%. The precision of the temperature control at a steady state temperature of 2000°C was 0.1%. The analytical improvements offered by the present system have been demonstrated by the determination of cadmium and lead in blood and finally by the determination of lead in serum. Both the sensitivity and the precision of the method have been improved. The accuracy of the method was checked by determining the lead content for a number of scrum samples both by ETA-AAS and differential pulse anodic stripping voltametry (DPASV) and proved to be satisfactory.

  17. Determination of cadmium in tobacco smoke by electrothermal atomic absorption spectroscopy with electrostatic precipitation of samples on the graphite tube atomizer

    NASA Astrophysics Data System (ADS)

    Altman, E. L.; Panichev, N. A.

    2003-05-01

    The determination of Cd in ambient air, associated with tobacco smoke, has been carried out by electrostatic precipitation of Cd directly in a graphite tube, which was subsequently used as an atomizer in electrothermal atomization atomic absorption spectroscopy (ET-AAS). It is shown that graphite tube permanently modified with Ir allows carrying out pyrolysis of collected samples at 1000^circC, leading to minimization of the blank. The combination of electrostatic precipitation of Cd from ambient air into the graphite tube with high efficiency of Cd determination by ET-AAS allows to trace Cd in ambient air for 25 min after the smoking a cigarette. The limit of detection (LOD) of Cd determination was found to be 0.2 ng m^{-3} The results of investigations confirm the danger of passive smoking due to the presence of Cd in smoking areas.

  18. Improved high-intensity microwave discharge lamp for atomic resonance absorption and fluorescence spectrometry.

    PubMed

    Lifshitz, A; Skinner, G B; Wood, D R

    1978-09-01

    An unusually good combination of high intensity and narrow line has been achieved in a microwave discharge lamp by placing the optical window in the center of the microwave cavity. Construction details and performance characteristics are described.

  19. Atomic Emission, Absorption and Fluorescence in the Laser-induced Plasma

    SciTech Connect

    Winefordner, J. D.

    2009-01-22

    The main result of our efforts is the development and successful application of the theoretical model of laser induced plasma (LIP) that allows a back-calculation of the composition of the plasma (and the condensed phase) based on the observable plasma spectrum. The model has an immediate experimental input in the form of LIP spectra and a few other experimentally determined parameters. The model is also sufficiently simple and, therefore, practical. It is conveniently interfaced in a graphical user-friendly form for using by students and any laboratory personnel with only minimal training. In our view, the model opens up the possibility for absolute analysis, i.e. the analysis which requires no standards and tedious calibration. The other parts of this proposal (including plasma diagnostics) were somewhat subordinate to this main goal. Plasma diagnostics provided the model with the necessary experimental input and led to better understanding of plasma processes. Another fruitful direction we pursued was the use of the correlation analysis for material identification and plasma diagnostics. Through a number of computer simulations we achieved a clear understanding of how, where and why this approach works being applied to emission spectra from a laser plasma. This understanding will certainly improve the quality of forensic and industrial analyses where fast and reliable material identification and sorting are required.

  20. Modifiers and coatings in graphite furnace atomic absorption spectrometry—mechanisms of action (A tutorial review)

    NASA Astrophysics Data System (ADS)

    Ortner, H. M.; Bulska, E.; Rohr, U.; Schlemmer, G.; Weinbruch, S.; Welz, B.

    2002-12-01

    furnace atomic absorption spectrometry (GFAAS): sample application and drying; pyrolysis; atomization. Contrary to the vast amount of literature on this topic it tried to provide the analyst working with GFAAS and in an increasing number working with Solid Sampling-GFAAS with a set of most important statements. This might spare the experimentalist a lot of useless optimization procedures but should lead him to a basic understanding of the complex phenomena taking place in his instrument and during his analytical work.

  1. Hydride generation in-atomizer collection atomic absorption spectrometry for the determination of antimony in acetic acid leachates from pewter cups.

    PubMed

    Dessuy, Morgana B; Kratzer, Jan; Vale, Maria Goreti R; Welz, Bernhard; Dědina, Jiří

    2011-12-15

    Antimony is one of the constituents of pewter, an alloy composed of a minimum of 90% tin with the balance being made up with copper, antimony and perhaps some bismuth. A method has been developed to determine Sb in acetic acid leachates from pewter cups. The employed instrumentation, an atomic absorption spectrometer, equipped with a quartz trap-and-atomizer device, is simple and relatively inexpensive with low running costs. Interferences due to the presence of tin and ways to control them were investigated in detail. The applied approach made possible to overcome potentially serious interference of Sn leached from the cup material (which was shown to take place in the atomizer), by a combination of (i) high concentration of HCl, which decreases the efficiency of stannane generation and (ii) in-atomizer collection. The resulting Sn tolerance limit was between 10 and 20 mg L(-1). The advantages of the in-atomizer collection are a lower tin interference in the atomizer, and a much better limit of detection (LOD), which makes possible reducing the atomization interference further by working with more diluted sample solutions. Besides the Sn interference, an interference of an unknown volatile compound transported to the atomizer together with stibine was identified in the measured sample solutions. This interference could be controlled using the analyte addition technique. The applicability of the method was tested on solutions containing a wide range of interferents leached from the pewter cups, obtained at leaching times between 1 and 24h. The LOD in the sample solutions was found to be 0.03 μg L(-1) Sb.

  2. The Growth and Mechanical Properties of Living Neurons Measured via Atomic Force and Fluorescence Microscopy

    NASA Astrophysics Data System (ADS)

    Spedden, Elise

    In this thesis we explore specific properties of the cytoskeleton and growth of living neurons via atomic force and fluorescence microscopies. We make the first comparative elastic modulus measurements on three types of neuronal cells plated on three types of substrate adhesion factors. We discover that during phases of active neurite extension the soma of cortical neurons stiffens reversibly due to changes in microtubule aggregation. Additionally, we demonstrate that mechanical properties of cortical neurons measured near physiological temperatures are primarily dependent on the microtubule component of the cytoskeleton. We further explore the response of the neuronal cytoskeleton to changes in ambient temperature. The elastic modulus of cortical neuron somas is discovered to increase dramatically upon a drop in ambient temperature. We determine through fluorescent staining and chemical modification of the cytoskeleton that this stiffening is due primarily to a change in the mechanically dominant component of the cytoskeleton from microtubules at 37ºC to actin at 25ºC precipitated by changes in myosin II dynamics within the cell. We make the first direct mechanical measurements of the pericellular brush layer on living neurons, demonstrating that the traditionally observed viscoelastic behavior of the neuronal soma is due to the properties of this brush layer. When the brush layer is excluded, the underlying soma is discovered to be both stiffer than previously observed, and elastic, with no loading-speed dependence to the elastic modulus under the test conditions. We additionally demonstrate that the soma elastic modulus, brush length, and brush density are all dependent on the ambient temperature. Finally, through fluorescent and bright field microscopies we track the outgrowth of living neurons on patterned directional surfaces, demonstrating that asymmetrical ratchet topographies unidirectionally bias axonal outgrowth. We model the outgrowth of the neurons

  3. Determination of cadmium and lead in edible oils by electrothermal atomic absorption spectrometry after reverse dispersive liquid-liquid microextraction.

    PubMed

    López-García, Ignacio; Vicente-Martínez, Yesica; Hernández-Córdoba, Manuel

    2014-06-01

    The dispersive liquid-liquid microextraction of edible oils with a low volume of an acidic solution in the presence of isopropyl alcohol allows cadmium and lead to be completely separated into the aqueous phase. After centrifugation, the metals are determined by electrothermal atomization atomic absorption spectrometry using a palladium salt for chemical modification in the heating cycle. Using a 10 g oil sample, the enrichment factor is 140, which permits detection limits of 0.6 and 10 ng kg(-1) for cadmium and lead, respectively. The results agree with those obtained after sample mineralization. Data for the cadmium and lead levels for 15 samples of different characteristics are given.

  4. Chromatography, Absorption, and Fluorescence: A New Instrumental Analysis Experiment on the Measurement of Polycyclic Aromatic Hydrocarbons in Cigarette Smoke

    NASA Astrophysics Data System (ADS)

    Wingen, Lisa M.; Low, Jason C.; Finlayson-Pitts, Barbara J.

    1998-12-01

    The recent approval by the American Chemical Society of an undergraduate chemistry degree with an option in environmental chemistry requires the development of new experiments that teach fundamental chemistry in the context of environmental issues. We present an experiment suitable for an undergraduate junior/senior-level instrumental analysis laboratory which illustrates the principles of high-performance liquid chromatography (HPLC) and its application to the identification and measurement of polycyclic aromatic hydrocarbons (PAH) in tobacco smoke. Absorption and fluorescence detection methods for PAH, especially the differences in sensitivity and selectivity of these methods, are clearly demonstrated along with the basic principles of HPLC.

  5. Role of non-Condon vibronic coupling and conformation change on two-photon absorption spectra of green fluorescent protein

    NASA Astrophysics Data System (ADS)

    Ai, Yuejie; Tian, Guangjun; Luo, Yi

    2013-07-01

    Two-photon absorption spectra of green fluorescent proteins (GFPs) often show a blue-shift band compared to their conventional one-photon absorption spectra, which is an intriguing feature that has not been well understood. We present here a systematic study on one- and two-photon spectra of GFP chromophore by means of the density functional response theory and complete active space self-consistent field (CASSCF) methods. It shows that the popular density functional fails to provide correct vibrational progression for the spectra. The non-Condon vibronic coupling, through the localised intrinsic vibrational modes of the chromophore, is responsible for the blue-shift in the TPA spectra. The cis to trans isomerisation can be identified in high-resolution TPA spectra. Our calculations demonstrate that the high level ab initio multiconfigurational CASSCF method, rather than the conventional density functional theory is required for investigating the essential excited-state properties of the GFP chromophore.

  6. Two-Photon Absorption and Fluorescence with Quadrupolar and Branched CHROMOPHORES—EFFECT of Structure and Branching

    NASA Astrophysics Data System (ADS)

    Porrès, Laurent; Mongin, Olivier; Katan, Claudine; Charlot, Marina; Bhatthula, Bharath Kumar Goud; Jouikov, Viatcheslav; Pons, Thomas; Mertz, Jerome; Blanchard-Desce, Mireille

    The photophysical and two-photon absorption (TPA) properties of three homologous quadrupolar and one related three-branched chromophores were investigated. Design of the quadrupoles is based on the symmetrical functionalization of a biphenyl core. Modulation of the nonlinear absorptivity/transparency/photostability trade-off can be achieved by playing with the twist angle of the core and on the spacers (phenylene-vinylene versus phenylene-ethynylene). The quadrupolar chromophores combine high TPA cross-sections, high fluorescence quantum yield and solvent sensitive photoluminescence properties. The branched structure exhibits spectrally broadened TPA in the NIR region (up to 3660 GM at 740 nm measured in the femtosecond regime) but reduced sensitivity to the environment.

  7. Direct analysis of reference biofluids by coupled in situ electrodeposition-electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Matousek, Jaroslav P.; Powell, Kipton J.

    1999-12-01

    The application of coupled in situ electrodeposition-electrothermal atomic absorption spectrometry (ED-ETAAS) to the determination of Pb in biological standard reference materials is described. In situ electrodeposition at a cell voltage of 3.0 V from 25-μl samples onto electrodeposited Pd is used to quantitatively separate the analyte from blood and urine matrices. With subsequent withdrawal of spent electrolyte, this overcomes the atomisation problems inherent with high salt and organic contents. ED-ETAAS is applied with minimal sample pre-treatment (acidification). The electrolysis process aids decomposition of the organic matrix, and the release of trace elements. Evolution of H 2 at the cathode counters fouling of the Pd modifier surface. The palladium deposit is renewed in situ for each determination. For AMI certified lyophilised blood, diluted 1+3 with 0.1 M HCl (18.1 μg/l Pb), the R.S.D. was 3.0% (peak height; n=5) and the detection limit (3 σ blank; n=5) was 1.5 μg/l. Results for certified blood samples were AMI 72.3±4.3 μg/l (certified 76.2±7.6 μg/l) and Seronorm 34.2±2.0 μg/l (36±4 μg/l). The result for NIST SRM 2670 normal urine acidified to 1% HNO 3 was 8.1±0.6 μg/l (recommended value 10 μg/l).

  8. [Determination of metals in Ginkgo biloba leaves by atomic absorption spectrometry with microwave digestion].

    PubMed

    Jiang, Bo; Jiang, Guo-Bin; Liu, Chang-Jian; Ma, Kun; Jin, Li-Ming; Gao, Jiang-Mei

    2010-03-01

    Microwave digestion technique was used in the decomposition of Ginkgo biloba leaves from six different trees at the same age in the same area. HNO3-H2O2 (5 : 1 v/v) was used as microwave digestion agent at a suitable temperature and time. The contents of Ca, Mg, K, Na, Cu, Zn and Zn/Cu were determined by flame atomic absorption spectrometry to study the distribution rule of metallic elements in the trees at the same age and in the same area. The recovery ratio ranged from 95.2% to 104.6%. The results showed that there were certain differences between different trees in the distribution of metallic elements. The contents of calcium were from 39 586 to 48 320 microg x g(-1), and those of magnesium from 10 076 to 12 918 microg x g(-1), of potassium from 2 004 to 5 240 microg x g(-1), of sodium from 9.05 to 35.30 microg x g(-1), and of copper from 1.50 to 3.05 microg x g(-1), while Zn/Cu values were from 2.68 to 5.93 in the leaves of 6 different trees in the same growing area. Therefore there were abounding calcium, magnesium and potassium, while the content of sodium and Zn/Cu values were lower, and the metal contents were different in the leaves. The experimental results provided useful bases for studying the distribution rule of metallic elements in Ginkgo biloba leaves, the relationship between the contents of calcium, magnesium, potassium and sodium and the Zn/Cu value in ginkgo biloba leaves and the treatment for cardio-cerebral vascular disease.

  9. Separation and quantitation of metallothioneins by high-performance liquid chromatography coupled with atomic absorption spectrophotometry

    SciTech Connect

    Lehman, L.D.; Klaassen, C.D.

    1986-03-01

    A rapid, reproducible, and sensitive high-performance liquid chromatography (HPLC) method for the determination of the concentrations of metallothionein-I (MT-I) and metallothionein-II (MT-II) in rat liver has been developed. Metallothioneins (MTs) were separated and quantitated by anion-exchange high-performance liquid chromatography coupled with atomic absorption spectrophotometry (AAS). Purified rat liver MT-I and MT-II, used as standards for developing the method, were easily resolved, eluting at 7.5 and 10.4 min, respectively. To establish standard curves, protein concentrations of solutions of the purified MTs were determined by the Kjeldahl method for the determination of nitrogen, after which the standards were saturated with Cd (final concentration of 50 ppm Cd). Rat liver cytosols obtained from untreated and Cd- or Zn-treated rats were prepared for HPLC-AAS analysis by saturation with Cd (50 ppm Cd) followed by heat denaturation (placing in a boiling water bath for 1 min). Based on the method of standard additions, recovery of MTs exceeded 95% and repeated injection of a sample yielded a coefficient of variance of approximately 2%. A detection limit of 5 ..mu..g MT/g liver was established for the method. Only MT-II was detected in untreated rats, whereas following exposure to Cd or Zn, both forms of MTs were detected. Concentrations of total MTs in liver of untreated and Cd- or Zn-treated rats were also determined by the Cd/hemoglobin radioassay (which fails to distinguish MT-I from MT-II) and indicated that results obtained with the HPLC-AAS method compared favorably to the Cd/hemoglobin radioassay.

  10. Determination of mercury in phosphate fertilizers by cold vapor atomic absorption spectrometry.

    PubMed

    de Jesus, Robson M; Silva, Laiana O B; Castro, Jacira T; de Azevedo Neto, Andre D; de Jesus, Raildo M; Ferreira, Sergio L C

    2013-03-15

    In this paper, a method for the determination of mercury in phosphate fertilizers using slurry sampling and cold vapor atomic absorption spectrometry (CV QT AAS) is proposed. Because mercury (II) ions form strong complexes with phosphor compounds, the formation of metallic mercury vapor requires the presence of lanthanum chloride as a release agent. Thiourea increases the amount of mercury that is extracted from the solid sample to the liquid phase of the slurry. The method is established using two steps. First, the slurry is prepared using the sample, lanthanum chloride, hydrochloric acid solution and thiourea solution and is sonicated for 20 min. Afterward, mercury vapor is generated using an aliquot of the slurry in the presence of the hydrochloric acid solution and isoamylic alcohol with sodium tetrahydroborate solution as the reducing agent. The experimental conditions for slurry preparation were optimized using two-level full factorial design involving the factors: thiourea and lanthanum chloride concentrations and the duration of sonication. The method allows the determination of mercury by external calibration using aqueous standards with limits of detection and quantification of 2.4 and 8.2 μg kg(-1), respectively, and precision, expressed as relative standard deviation, of 6.36 and 5.81% for two phosphate fertilizer samples with mercury concentrations of 0.24 and 0.57 mg kg(-1), respectively. The accuracy was confirmed by the analysis of a certified reference material of phosphate fertilizer that was provided by the National Institute of Standards & Technology (NIST). The method was applied to determine mercury in six commercial samples of phosphate fertilizers. The mercury content varied from 33.97 to 209.28 μg kg(-1). These samples were also analyzed employing inductively coupled plasma mass spectrometry (ICP-MS). The ICP-MS results were consistent with the results from our proposed method.

  11. Matrix effects on the determination of manganese in geological materials by atomic-absorption spectrophotometry under different flame conditions

    USGS Publications Warehouse

    Sanzolone, R.F.; Chao, T.T.

    1978-01-01

    Suppression caused by five of the seven matrix elements studied (Si, Al, Fe, Ca and Mg) was observed in the atomic-absorption determination of manganese in geological materials, when synthetic solutions and the recommended oxidizing air-acetylene flame were used. The magnitude of the suppression effects depends on (1) the kind and concentration of the interfering elements, (2) the type of acid medium, and (3) the concentration of manganese to be determined. All interferences noted are removed or alleviated by using a reducing nitrous oxide-acetylene flame. The atomic-absorption method using this flame can be applied to the determination of total and extractable manganese in a wide range of geological materials without interferences. Analyses of six U.S. Geological Survey rock standards for manganese gave results in agreement with the reported values. ?? 1978.

  12. Metastable argon atom density in complex argon/acetylene plasmas determined by means of optical absorption and emission spectroscopy

    NASA Astrophysics Data System (ADS)

    Sushkov, Vladimir; Herrendorf, Ann-Pierra; Hippler, Rainer

    2016-10-01

    Optical emission and absorption spectroscopy has been utilized to investigate the instability of acetylene-containing dusty plasmas induced by growing nano-particles. The density of Ar(1s5) metastable atoms was derived by two methods: tunable diode laser absorption spectroscopy and with the help of the branching ratio method of emitted spectral lines. Results of the two techniques agree well with each other. The density of Ar(1s3) metastable atoms was also measured by means of optical emission spectroscopy. The observed growth instability leads to pronounced temporal variations of the metastable and other excited state densities. An analysis of optical line ratios provides evidence for a depletion of free electrons during the growth cycle but no indication for electron temperature variations.

  13. Sample pre-treatment methods for the trace elements determination in seafood products by atomic absorption spectrometry.

    PubMed

    Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio; Bermejo-Barrera, Adela

    2002-07-03

    Different sample pre-treatments for seafood products have been compared with determine trace elements (As, Cd, Cr, Cu, Fe, Mg, Mn, Ni, Pb, Se and Zn) by flame atomic absorption spectrometry (FAAS) and electrothermal atomic absorption spectrometry (ETAAS). Classic pre-treatments as microwave assisted-acid digestion and the slurry sampling technique were compared with new procedures such as microwave energy or ultrasound energy assisted-acid leaching process and enzymatic hydrolysis methodologies based on the use of pronase E. The methods were applied to DORM-1 and DOLT-1 reference materials with certified contents for the studied elements. The Student-Newman-Keuls (SNK) method was used to compare with element concentration means obtained with each sample pre-treatment and also the certified concentration means in both reference materials. Multivariate techniques such as principal components analysis (PCA) was also applied to comparative purposes.

  14. Arsenic in marine tissues — The challenging problems to electrothermal and hydride generation atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Karadjova, Irina B.; Petrov, Panayot K.; Serafimovski, Ivan; Stafilov, Trajče; Tsalev, Dimiter L.

    2007-03-01

    Analytical problems in determination of arsenic in marine tissues are addressed. Procedures for the determination of total As in solubilized or extracted tissues with tetramethylammonium hydroxide and methanol have been elaborated. Several typical lyophilized tissues were used: NIST SRM 1566a 'Oyster Tissue', BCR-60 CRM 'Trace Elements in an Aquatic Plant ( Lagarosiphon major)', BCR-627 'Forms of As in Tuna Fish Tissue', IAEA-140/TM 'Sea Plant Homogenate', NRCC DOLT-1 'Dogfish Liver' and two representatives of the Black Sea biota, Mediterranean mussel ( Mytilus galloprovincialis) and Brown algae ( Cystoseira barbata). Tissues (nominal 0.3 g) were extracted in tetramethylammonium hydroxide (TMAH) 1 ml of 25% m/v TMAH and 2 ml of water) or 5 ml of aqueous 80% v/v methanol (MeOH) in closed vessels in a microwave oven at 50 °C for 30 min. Arsenic in solubilized or extracted tissues was determined by electrothermal atomic absorption spectrometry (ETAAS) after appropriate dilution (nominally to 25 ml, with further dilution as required) under optimal instrumental parameters (pyrolysis temperature 900 °C and atomization temperature 2100 °C) with 1.5 μg Pd as modifier on Zr-Ir treated platform. Platforms have been pre-treated with 2.7 μmol of zirconium and then with 0.10 μmol of iridium which served as a permanent chemical modifier in direct ETAAS measurements and as an efficient hydride sequestration medium in flow injection hydride generation (FI-HG)-ETAAS. TMAH and methanol extract 96-108% and 51-100% of As from CRMs. Various calibration approaches have been considered and critically evaluated. The effect of species-dependent slope of calibration graph or standard additions plot for total As determination in a sample comprising of several individual As species with different ETAAS behavior has been considered as a kind of 'intrinsic element speciation interference' that cannot be completely overcome by standard additions technique. Calibration by means of CRMs has

  15. Atomic-force and fluorescence microscopy of Langmuir-Blodgett monolayers of [ital L]-[alpha]-dimyristoylphosphatidic acid

    SciTech Connect

    Mikrut, J.M. ); Dutta, P.; Ketterson, J.B. ); MacDonald, R.C. )

    1993-11-15

    We have obtained fluorescence and atomic-force-microscopy images of the liquid and solid phases of Langmuir-Blodgett monolayers of [ital L]-[alpha]-dimyristoylphosphatidic acid, some containing [similar to]1 mol % of [ital L]-[alpha]-phosphatidylethanolamine-[ital N]-4-nitrobenzo-2-oxa-1,3-diazole. The fluorescence microscopy images are similar to those of monolayers at the air-water interface, but slight differences indicate that changes occur in the monolayers as a result of the deposition process. The atomic-force-microscopy images show the clean glass substrates to be very much rougher than when the monolayers are deposited on them. We propose that a water layer provides a smooth surface on which the Langmuir-Blodgett monolayers rest. We measured a [similar to]25-A height difference between the liquid and solid phase region, one explanation being that the alkyl chains of the molecule are standing up in the solid phase and lying down in the liquid phase. This result is consistent with the fluorescence and atomic-force-microscopy images which show an increase in the amount of solid phase domains as a result of the deposition process. Further, the atomic-force-microscopy images of the monolayers show features which have not been described before and which could not be attributed to the presence of the dye. Finally, we showed that if the Langmuir-Blodgett monolayers are not stored in a humid environment, they begin to collapse into multilayers.

  16. Determination of cadmium in water samples by fast pyrolysis-chemical vapor generation atomic fluorescence spectrometry

    NASA Astrophysics Data System (ADS)

    Zhang, Jingya; Fang, Jinliang; Duan, Xuchuan

    2016-08-01

    A pyrolysis-vapor generation procedure to determine cadmium by atomic fluorescence spectrometry has been established. Under fast pyrolysis, cadmium ion can be reduced to volatile cadmium species by sodium formate. The presence of thiourea enhanced the efficiency of cadmium vapor generation and eliminated the interference of copper. The possible mechanism of vapor generation of cadmium was discussed. The optimization of the parameters for pyrolysis-chemical vapor generation, including pyrolysis temperature, amount of sodium formate, concentration of hydrochloric acid, and carrier argon flow rate were carried out. Under the optimized conditions, the absolute and concentration detection limits were 0.38 ng and 2.2 ng ml- 1, respectively, assuming that 0.17 ml of sample was injected. The generation efficiency of was 28-37%. The method was successfully applied to determine trace amounts of cadmium in two certified reference materials of Environmental Water (GSB07-1185-2000 and GSBZ 50009-88). The results were in good agreement with the certified reference values.

  17. [Research on optimization of mathematical model of flow injection-hydride generation-atomic fluorescence spectrometry].

    PubMed

    Cui, Jian; Zhao, Xue-Hong; Wang, Yan; Xiao, Ya-Bing; Jiang, Xue-Hui; Dai, Li

    2014-01-01

    Flow injection-hydride generation-atomic fluorescence spectrometry was a widely used method in the industries of health, environmental, geological and metallurgical fields for the merit of high sensitivity, wide measurement range and fast analytical speed. However, optimization of this method was too difficult as there exist so many parameters affecting the sensitivity and broadening. Generally, the optimal conditions were sought through several experiments. The present paper proposed a mathematical model between the parameters and sensitivity/broadening coefficients using the law of conservation of mass according to the characteristics of hydride chemical reaction and the composition of the system, which was proved to be accurate as comparing the theoretical simulation and experimental results through the test of arsanilic acid standard solution. Finally, this paper has put a relation map between the parameters and sensitivity/broadening coefficients, and summarized that GLS volume, carrier solution flow rate and sample loop volume were the most factors affecting sensitivity and broadening coefficients. Optimizing these three factors with this relation map, the relative sensitivity was advanced by 2.9 times and relative broadening was reduced by 0.76 times. This model can provide a theoretical guidance for the optimization of the experimental conditions.

  18. Determination of As, Cd, Cu, Hg and Pb in biological samples by modern electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Sardans, Jordi; Montes, Fernando; Peñuelas, Josep

    2010-02-01

    Pollution from heavy metals has increased in recent decades and has become an important concern for environmental agencies. Arsenic, cadmium, copper, mercury and lead are among the trace elements that have the greatest impact and carry the highest risk to human health. Electrothermal atomic absorption spectrometry (ETAAS) has long been used for trace element analyses and over the past few years, the main constraints of atomic absorption spectrometry (AAS) methods, namely matrix interferences that provoked high background absorption and interferences, have been reduced. The use of new, more efficient modifiers and in situ trapping methods for stabilization and pre-concentration of these analytes, progress in control of atomization temperatures, new designs of atomizers and advances in methods to correct background spectral interferences have permitted an improvement in sensitivity, an increase in detection power, reduction in sample manipulation, and increase in the reproducibility of the results. These advances have enhanced the utility of Electrothermal atomic absorption spectrometry (ETAAS) for trace element determination at μg L -1 levels, especially in difficult matrices, giving rise to greater reproducibility, lower economic cost and ease of sample pre-treatment compared to other methods. Moreover, the recent introduction of high resolution continuum source Electrothermal atomic absorption spectrometry (HR-CS-ETAAS) has facilitated direct solid sampling, reducing background noise and opening the possibility of achieving even more rapid quantitation of some elements. The incorporation of flow injection analysis (FIA) systems for automation of sample pre-treatment, as well as chemical vapor generation renders (ETAAS) into a feasible option for detection of As and Hg in environmental and food control studies wherein large numbers of samples can be rapidly analyzed. A relatively inexpensive approach with low sample consumption provide additional advantages of

  19. Wear-metal analysis in engine oil by microwave digestion and atomic absorption spectroscopy. Final report, August 1987-January 1988

    SciTech Connect

    Muse, W.T.

    1990-05-01

    Digestion procedures are described for the analysis of wear metals in National Bureau of Standards (NBS) oil samples by a closed vessel microwave digestion system. Samples were analyzed by flame atomic absorption spectroscopy. Recoveries of Al, Fe, Ni, Cu, and Pb in the 300-ppm NBS oil ranged from 98 to 103% with standard deviations from 3 to 14%. This method serves as a relatively quick matrix destruction technique for the quantitation of metals in oil.

  20. Determination of the total iron content of used lubricating oils by atomic-absorption with use of emulsions.

    PubMed

    Salvador, A; de la Guardia, M; Berenguer, V

    1983-12-01

    A new method is proposed for the determination of the total iron content of used lubricating oils. It is based on treatment of the samples with a mixture of hydrofluoric and nitric acids (without destruction of the organic matter) and emulsification, followed by atomic-absorption measurement. This allows the use of aqueous standards and provides a simple, rapid, inexpensive and accurate method, that is not affected by the particle size of the solids in the oil.

  1. Robotized sampling device for graphite furnace atomic absorption spectrometry slurry analysis with Varian SpectrAA instruments

    NASA Astrophysics Data System (ADS)

    Hoenig, Michel; Cilissen, Anne

    1993-08-01

    There is a growing interest in the determination by electrothermal atomic absorption spectrometry (ETAAS) of elements in solid samples without a dissolution stage, to avoid contamination and losses during the preparation of the sample. This approach may be particularly convenient when only small amounts of sample are available. Details of the above-mentioned program for the adaptation of the Gilson sample changer to Varian SpectrAA systems (X,Y,Z positions, timings etc.) are available on request.

  2. High energy resolution five-crystal spectrometer for high quality fluorescence and absorption measurements on an x-ray absorption spectroscopy beamline

    SciTech Connect

    Llorens, Isabelle; Lahera, Eric; Delnet, William; Proux, Olivier; Dermigny, Quentin; Gelebart, Frederic; Morand, Marc; Shukla, Abhay; Bardou, Nathalie; Ulrich, Olivier; and others

    2012-06-15

    Fluorescence detection is classically achieved with a solid state detector (SSD) on x-ray absorption spectroscopy (XAS) beamlines. This kind of detection however presents some limitations related to the limited energy resolution and saturation. Crystal analyzer spectrometers (CAS) based on a Johann-type geometry have been developed to overcome these limitations. We have tested and installed such a system on the BM30B/CRG-FAME XAS beamline at the ESRF dedicated to the structural investigation of very dilute systems in environmental, material and biological sciences. The spectrometer has been designed to be a mobile device for easy integration in multi-purpose hard x-ray synchrotron beamlines or even with a laboratory x-ray source. The CAS allows to collect x-ray photons from a large solid angle with five spherically bent crystals. It will cover a large energy range allowing to probe fluorescence lines characteristic of all the elements from Ca (Z = 20) to U (Z = 92). It provides an energy resolution of 1-2 eV. XAS spectroscopy is the main application of this device even if other spectroscopic techniques (RIXS, XES, XRS, etc.) can be also achieved with it. The performances of the CAS are illustrated by two experiments that are difficult or impossible to perform with SSD and the complementarity of the CAS vs SSD detectors is discussed.

  3. Differentiation and classification of beers with flame atomic spectrometry and molecular absorption spectrometry and sample preparation assisted by microwaves

    NASA Astrophysics Data System (ADS)

    Bellido-Milla, Dolores; Moreno-Perez, Juana M.; Hernández-Artiga, María. P.

    2000-07-01

    The characterization of beer samples has a lot of interest because their composition can affect the taste and stability of beer and consumer health. Flame atomic absorption spectrometry was used to determine Fe, Mn, Zn, Cu, Mg, Ca and Al. Sodium and K were determined by flame atomic emission spectrometry. A sample preparation method was developed, based on treatment with HNO 3 and H 2O 2 in a microwave oven. This has many advantages over the methods found in the literature. The combination of the results of atomic spectrometry and the spectrum obtained by molecular absorption spectrometry provides information on the inorganic and organic components of the samples. The application of chemometric techniques to chemical composition data could be extremely useful for food quality control. The metal concentrations, the molecular absorption spectrum, the pH and conductivity of each sample were subject to analysis of variance and linear discriminant analysis. Twenty-five different beer samples were used to differentiate and classify different types of beers.

  4. Evaluation of the memory effect on gold-coated silica adsorption tubes used for the analysis of gaseous mercury by cold vapor atomic absorption spectrometry.

    PubMed

    Rahman, Mohammad Mahmudur; Brown, Richard J C; Kim, Ki-Hyun; Yoon, Hye-On; Phan, Nhu-Thuc

    2013-01-01

    In an effort to reduce the experimental bias involved in the analysis of gaseous elemental mercury (Hg(o)), the blank response from gold-coated adsorption tubes has been investigated using cold vapor atomic absorption spectrometry (CVAAS). Our study has been compared with our recent investigation on memory effect in a cold vapour atomic fluorescence spectrometry (CVAFS). The pattern of blank responses was quantified after loading different amounts of mercury and after different time intervals of 1, 14, and 45 days. In case of the one day interval, the result of five to six instant blank heating cycles confirmed successful liberation of mercury following the second and third blank heating cycles. The results of 14 or 45 days generally suggest that liberation of excess mercury is affected by both the initial loading amount and the length of storage time prior to analysis. We have demonstrated a possibly effective way to reduce memory effects. Some similarities of these results with those from CVAFS experiment suggests that the blank response is caused by a combination of mercury absorbed within the bulk gold and micro- and nanoparticles liberated during heating and not from coabsorbing interfering gaseous species.

  5. Evaluation of the Memory Effect on Gold-Coated Silica Adsorption Tubes Used for the Analysis of Gaseous Mercury by Cold Vapor Atomic Absorption Spectrometry

    PubMed Central

    Rahman, Mohammad Mahmudur; Brown, Richard J. C.; Yoon, Hye-On; Phan, Nhu-Thuc

    2013-01-01

    In an effort to reduce the experimental bias involved in the analysis of gaseous elemental mercury (Hgo), the blank response from gold-coated adsorption tubes has been investigated using cold vapor atomic absorption spectrometry (CVAAS). Our study has been compared with our recent investigation on memory effect in a cold vapour atomic fluorescence spectrometry (CVAFS). The pattern of blank responses was quantified after loading different amounts of mercury and after different time intervals of 1, 14, and 45 days. In case of the one day interval, the result of five to six instant blank heating cycles confirmed successful liberation of mercury following the second and third blank heating cycles. The results of 14 or 45 days generally suggest that liberation of excess mercury is affected by both the initial loading amount and the length of storage time prior to analysis. We have demonstrated a possibly effective way to reduce memory effects. Some similarities of these results with those from CVAFS experiment suggests that the blank response is caused by a combination of mercury absorbed within the bulk gold and micro- and nanoparticles liberated during heating and not from coabsorbing interfering gaseous species. PMID:23589708

  6. Distinguishing plasmonic absorption modes by virtue of inversed architectures with tunable atomic-layer-deposited spacer layer

    NASA Astrophysics Data System (ADS)

    Zhang, Yun; Zhang, Kenan; Zhang, Tianning; Sun, Yan; Chen, Xin; Dai, Ning

    2014-12-01

    We demonstrated the distinguishing between plasmonic absorption modes by exploiting an inversed architecture with tunable atomic-layer-deposited dielectric spacer layer. The dielectric spacer layer was manipulated between the bottom metal-nanoparticle monolayer and the upper metal film to inspect the contributions of metal nanoparticles and dielectric film in a step-by-step manner. The experimental and simulated differences between the two peak absorption positions (Δf) and between the corresponding half width at half maxima (Δw) confirmed the evolutions of gap plasmon and interference-enhanced local surface plasmon resonance absorption modes in the plasmonic metamaterial absorbers (PMAs), which were useful for understanding the underlying mechanism of amorphous PMAs.

  7. Study of the Many Fluorescent Lines and the Absorption Variability in GX 301-2 with XMM-Newton

    NASA Technical Reports Server (NTRS)

    Fuerst, F.; Suchy, S.; Kreykenbohm, I.; Barragan, L.; Wilms, J.; Pottschmidt, K.; Caballero, I.; Kretschmar, P.; Ferrigno, C.; Rothschild, R. E.

    2011-01-01

    We present an in-depth study of the High Mass X-ray Binary (HMXB) GX 301-2 during its pre-periastron flare using data from the XMM-Newton satellite. The energy spectrum shows a power law continuum absorbed by a large equivalent hydrogen column on the order of 10(exp 24)/ sq cm and a prominent Fe K-alpha fluorescent emission line. Besides the Fe K-alpha line, evidence for Fe K-Beta, Ni K-alpha, Ni K-Beta, S K-alpha, Ar K-alpha, Ca K-alpha, and Cr K-alpha fluorescent lines is found. The observed line strengths are consistent with fluorescence in a cold absorber. This is the first time that Cr K-alpha is seen in emission in the X-ray spectrum of a HMXB. In addition to the modulation by the strong pulse period of approx 685 sec the source is highly variable and shows different states of activity. We perform time-resolved as well as pulse-to-pulse resolved spectroscopy to investigate differences between these states of activity. We find that fluorescent line fluxes are strongly variable and generally follow the overall flux. The N-H value is variable by a factor of 2, but not correlated to continuum normalization. We find an interval of low flux in the light curve in which the pulsations cease almost completely, without any indication of an increasing absorption column. We investigate this dip in detail and argue that it is most likely that during the dip the accretion ceased and the afterglow of the fluorescent iron accounted for the main portion of the X-ray flux. A similar dip was found earlier in RXTE data, and we compare our findings to these results.

  8. Absorption and fluorescence spectroscopic characterisation of the circadian blue-light photoreceptor cryptochrome from Drosophila melanogaster (dCry)

    NASA Astrophysics Data System (ADS)

    Shirdel, J.; Zirak, P.; Penzkofer, A.; Breitkreuz, H.; Wolf, E.

    2008-09-01

    The absorption and fluorescence behaviour of the circadian blue-light photoreceptor cryptochrome from Drosophila melanogaster (dCry) in a pH 8 aqueous buffer solution is studied. The flavin adenine dinucleotide (FAD) cofactor of dCry is identified to be present in its oxidized form (FAD ox), and the 5,10-methenyltetrahydrofolate (MTHF) cofactor is found to be hydrolyzed and oxidized to 10-formyldihydrofolate (10-FDHF). The absorption and the fluorescence behaviour of dCry is investigated in the dark-adapted (receptor) state, the light-adapted (signalling) state, and under long-time violet light exposure. Photo-excitation of FAD ox in dCry causes a reductive electron transfer to the formation of anionic FAD semiquinone (FAD rad - ), and photo-excitation of the generated FAD rad - causes an oxidative electron transfer to the back formation of FAD ox. In light adapted dCry a photo-induced equilibrium between FAD ox and FAD rad - exists. The photo-cycle dynamics of signalling state formation and recovery is discussed. Quantum yields of photo-induced signalling state formation of about 0.2 and of photo-induced back-conversion of about 0.2 are determined. A recovery of FAD rad - to FAD ox in the dark with a time constant of 1.6 min at room temperature is found.

  9. Excited state dipole moments of N, N-dimethylaniline from thermochromic effect on electronic absorption and fluorescence spectra

    NASA Astrophysics Data System (ADS)

    Kawski, A.; Kukliński, B.; Bojarski, P.

    2006-01-01

    The effect of temperature on absorption and fluorescence spectra of N, N-dimethylaniline (DMA) in ethyl acetate has been studied for temperature ranging from 293 to 388 K. The permittivity ɛ and refractive index n of the solvent decrease with temperature increase and the absorption and fluorescence bands are blue shifted (so-called "thermochromic shift"). Based on this phenomenon, the dipole moment μe in the excited singlet state and the Onsager interaction radius a for DMA were determined using the Bilot and Kawski theory [L. Bilot, A. Kawski, Z. Naturforsch. 17a (1962) 621; 18a (1963) 10, 256]. For the known dipole moment in the ground state μg = 1.61 D and for α/ a3 = 0.54 ( α is the polarizability of the solute) the average value of μe = 3.55 D and a = 3.1 Å were determined. The obtained values for DMA are compared with the experimental values determined by other authors.

  10. [The absorption and fluorescence spectra of the cyanobacterial phycobilins of cryptoendolithic lichens in the high-polar region of Antarctica].

    PubMed

    Erokhina, L G; Shatilovich, A V; Kaminskaia, O P; Gilichinskiĭ, D A

    2002-01-01

    The algologically pure cultures of the green-brown cyanobacterium Chroococcidiopsis sp. and three cyanobacteria of the genus Gloeocapsa, the blue-green Gloeocapsa sp.1, the brown Gloeocapsa sp.2, and the red-orange Gloeocapsa sp.3, were isolated from sandstones and rock fissures in the high-polar regions of Antarctica. These cyanobacteria are the most widespread phycobionts of cryptoendolithic lichens in these regions. The comparative analysis of the absorption and the second-derivative absorption spectra of the cyanobacteria revealed considerable differences in the content of chlorophyll a and in the content and composition of carotenoids and phycobiliproteins. In addition to phycocyanin, allophycocyanin, and allophycocyanin B, which were present in all of the cyanobacteria studied, Gloeocapsa sp.2 also contained phycoerythrocyanin and Gloeocapsa sp.3 phycoerythrocyanin and C-phycoerythrin (the latter pigment is typical of nitrogen-fixing cyanobacteria). The fluorescence spectra of Gloeocapsa sp.2 and Gloeocapsa sp.3 considerably differed from the fluorescence spectra of the other cyanobacteria as well. The data obtained suggest that various zones of the lichens may be dominated either by photoheterotrophic or photoautotrophic cyanobacterial phycobionts, which differ in the content and composition of photosynthetic pigments.

  11. Separation and preconcentration of chromium species by selective absorption on Lemna minor and determination by slurry atomisation electrothermal atomic absorption spectrometry.

    PubMed

    Zhu, G; Li, S

    2001-08-01

    A novel method for the separation and preconcentration of Cr(III)/Cr(VI) with Lemna minor and determination by slurry atomization electrothermal atomic absorption spectrometry (ETAAS) was developed. A sample solution was added to a polyethylene beaker containing 10 mg of 160 mesh pre-treated Lemna minor, adjusted to pH 1.0, stirred for 8 min for selective absorption of Cr(III) and then centrifuged. The upper layer of solution was transferred into another polyethylene beaker containing 10 mg of 160 mesh pre-treated Lemna minor, adjusted to pH 5.0, stirred for 12 min for adsorption of the residual Cr(VI) and centrifuged. The two residues in two centrifuge tubes were washed twice with water, 2 ml of agar solution added, stirred for 2 min, then two slurries were prepared and used for the determination of Cr(III) and Cr(VI) by ETAAS. Detection limits (3sigma) of 0.01 microg L(-1) for Cr(III) and 0.03 microg L(-1) for Cr(VI) were obtained. The relative standard deviation was 2.8% for Cr(III) and 3.3% for Cr(VI) at the 1 microg L(-1) level. The method was applied to the determination of Cr(III)/Cr(VI) in water samples. The analytical recoveries of Cr(III) and Cr(VI) added to samples were 97-102 and 96-103%, respectively.

  12. Determination of lithium isotopes at natural abundance levels by atomic absorption spectrometry

    USGS Publications Warehouse

    Meier, A.L.

    1982-01-01

    The relationships of the absorption of 6Li and 7Li hollow cathode lamp emissions are used to determine lithium isotopic composition in the natural abundance range of geologic materials. Absorption was found to have a nonlinear dependence upon total lithium concentration and isotopic composition. A method using nonlinear equations to describe the relationship of the absorption of 6Li and 7Li lamp radiation is proposed as a means of calculating isotopic composition that is independent of total lithium concentration.

  13. A passive measurement of dissociated atom densities in atmospheric pressure air discharge plasmas using vacuum ultraviolet self-absorption spectroscopy

    SciTech Connect

    Laity, George; Fierro, Andrew; Dickens, James; Neuber, Andreas; Frank, Klaus

    2014-03-28

    We demonstrate a method for determining the dissociation degree of atmospheric pressure air discharges by measuring the self-absorption characteristics of vacuum ultraviolet radiation from O and N atoms in the plasma. The atom densities are determined by modeling the amount of radiation trapping present in the discharge, without the use of typical optical absorption diagnostic techniques which require external sources of probing radiation into the experiment. For an 8.0 mm spark discharge between needle electrodes at atmospheric pressure, typical peak O atom densities of 8.5 × 10{sup 17} cm{sup −3} and peak N atom densities of 9.9 × 10{sup 17} cm{sup −3} are observed within the first ∼1.0 mm of plasma near the anode tip by analyzing the OI and NI transitions in the 130.0–132.0 nm band of the vacuum ultraviolet spectrum.

  14. Determination of yttrium and rare-earth elements in rocks by graphite-furnace atomic-absorption spectrometry.

    PubMed

    Gupta, J G

    1981-01-01

    With use of synthetic solutions and several international standard reference materials a method has been developed for determining traces of Y, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu in rocks by electrothermal atomization in a pyrolytically-coated graphite furnace. Depending on the element, the sensitivity is of the order of 10(-9)-10(-12) g at 2500 degrees . To avoid matrix interferences the lanthanides are separated from the common elements by co-precipitation with calcium and iron as carriers. The data for Canadian reference rock SY-2 (syenite), U.S.G.S. reference rocks W-2 (diabase), DNC-1 (diabase) and BIR-1 (basalt), and South African reference rock NIM-18/69 (carbonatite) obtained by graphite-furnace atomization are compared with the values obtained by flame atomic-absorption. The results are in good agreement with literature values.

  15. Quantitative two-photon laser-induced fluorescence of hydrogen atoms in a 1 kW arcjet thruster

    NASA Astrophysics Data System (ADS)

    Wysong, I. J.; Pobst, J. A.

    1998-08-01

    Quantitative measurements of atomic hydrogen are reported for an arcjet thruster using two-photon laser-induced fluorescence. Number density, axial and radial velocity, and temperature of ground state atomic hydrogen are obtained at the nozzle exit plane and in the downstream plume of a 1 kW arcjet operating on hydrogen propellant. Details of the technique and data analysis are provided. Comparisons with other related available data are made, as well as with several computational models. The observed dissociation fraction of 31ᆢ %is significantly higher than predicted by the models.

  16. Study of the Photodegradation Process of Vitamin E Acetate by Optical Absorption, Fluorescence, and Thermal Lens Spectroscopy

    NASA Astrophysics Data System (ADS)

    Tiburcio-Moreno, J. A.; Marcelín-Jiménez, G.; Leanos-Castaneda, O. L.; Yanez-Limon, J. M.; Alvarado-Gil, J. J.

    2012-11-01

    The stability of vitamin E acetate exposed to ultraviolet (UV) light was studied using three spectroscopic methods. An ethanol solution of vitamin E acetate was treated with either UVC light (254 nm) or UVA light (366 nm) during a period of 10 min followed by a study of UV-Vis optical absorption, then by fluorescence spectroscopy excitation by UV radiation at either 290 nm or 368 nm and, finally the solution was studied by thermal lens spectroscopy. Immediately, the same solution of vitamin E acetate was subjected to the UV irradiation process until completion of six periods of irradiation and measurements. UVC light treatment induced the appearance of a broad absorption band in the range of 310 nm to 440 nm with maximum absorbance at 368 nm, which progressively grew as the time of the exposure to UVC light increases. In contrast, UVA light treatment did not affect the absorption spectra of vitamin E acetate. Fluorescence spectra of the vitamin E acetate (without UV light treatment) showed no fluorescence when excited with 368 nm while exciting with 290 nm, an intense and broad emission band (300 nm to 440 nm) with a maximum at 340 nm appeared. When vitamin E acetate was treated with UVC light, this emission band progressively decreased as the time of the UVC light irradiation grew. No signal from UV-untreated vitamin E acetate could be detected by the thermal lens method. Interestingly, as the time of the UVC light treatment increased, the thermal lens signal progressively grew. Additional experiments performed to monitor the time evolution of the process during continuous UVC treatment of the vitamin E acetate using thermal lens spectroscopy exhibited a progressive increase of the thermal lens signal reaching a plateau at about 8000 s. This study shows that the vitamin E acetate is stable when it is irradiated with UVA light, while the irradiation with UVC light induces the formation of photodegradation products. Interestingly, this photodegradation process using

  17. A sensitive atomic-absorption spectrometric method for the determination of tin with atomization from impregnated graphite surfaces.

    PubMed

    Fritzsche, H; Wegscheider, W; Knapp, G; Ortner, H M

    1979-03-01

    The atomization of Sn from graphite surfaces is potentially hindered by reactions with the surface. The impregnation of graphite tubes with other carbide-forming elements (W, Zr, Ta, Mo) favourably alters the surface characteristics of the graphite furnace for the atomization of Sn. At the acid concentrations needed to prevent the hydrolysis of Sn, these surfaces are considerably more stable (even after more than 100 atomization cycles) than those of pyrolytic graphite. Two graphite furnaces of different design, the HGA 72 and the HGA 76, were tested. With impregnated graphite tubes the determination of Sn is possible in the HGA 72 with a detection limit of approximately 15 pg. In the HGA 76 the tin determination is vastly improved with respect to prolonged lifetime of the furnaces and stable signals over much longer periods of time. Detailed interference studies reveal that the use of the "gas stop" mode minimizes the influence of many ions that are frequently either introduced by the decomposition reagents or present in the sample itself. The practical potential of this method is demonstrated for the determination of Sn in a slag material and in copper- and aluminium-based alloys.

  18. Selenium speciation by high-performance anion-exchange chromatography-post-column UV irradiation coupled with atomic fluorescence spectrometry.

    PubMed

    Liang, Lina; Mo, Shumin; Zhang, Ping; Cai, Yaqi; Mou, Shifen; Jiang, Guibin; Wen, Meijuan

    2006-06-16

    A technique for the speciation of selenomethylcysteine (SeMeCys), selenocystine (SeCys), selenite [Se(IV)] and selenomethionine (SeMet) was established in this paper using high-performance anion-exchange chromatography coupled with atomic fluorescence spectrometry (HPAEC-AFS). Analytes were separated on an AminoPac PA10 column and then digested by on-line ultraviolet (UV) irradiation, which destroyed organic compound structure. Hydride generation was used as an available sample introduction technique for atomic fluorescence detection. The detection limits of four compounds were 1-5 microg/L (250 microL injection, 10 times of the baseline noise). The relative standard deviations (RSDs), calculated from seven consecutive injections of 100 microg/L standard mixtures, were from 2 to 4%. Selenious yeast tablet, which had been proposed as selenium supplement, and human urine collected from a volunteer were analyzed. Good spiked recoveries from 86 to 103% were obtained.

  19. Combined X-ray fluorescence and absorption computed tomography using a synchrotron beam

    NASA Astrophysics Data System (ADS)

    Hall, C.

    2013-06-01

    X-ray computed tomography (CT) and fluorescence X-ray computed tomography (FXCT) using synchrotron sources are both useful tools in biomedical imaging research. Synchrotron CT (SRCT) in its various forms is considered an important technique for biomedical imaging since the phase coherence of SR beams can be exploited to obtain images with high contrast resolution. Using a synchrotron as the source for FXCT ensures a fluorescence signal that is optimally detectable by exploiting the beam monochromaticity and polarisation. The ability to combine these techniques so that SRCT and FXCT images are collected simultaneously, would bring distinct benefits to certain biomedical experiments. Simultaneous image acquisition would alleviate some of the registration difficulties which comes from collecting separate data, and it would provide increased information about the sample: functional X-ray images from the FXCT, with the morphological information from the SRCT. A method is presented for generating simultaneous SRCT and FXCT images. Proof of principle modelling has been used to show that it is possible to recover a fluorescence image of a point-like source from an SRCT apparatus by suitably modulating the illuminating planar X-ray beam. The projection image can be successfully used for reconstruction by removing the static modulation from the sinogram in the normal flat and dark field processing. Detection of the modulated fluorescence signal using an energy resolving detector allows the position of a fluorescent marker to be obtained using inverse reconstruction techniques. A discussion is made of particular reconstruction methods which might be applied by utilising both the CT and FXCT data.

  20. Determination of antimony, arsenic, bismuth, selenium, tellurium and tin by low pressure atomic absorption spectrometry with a quartz tube furnace atomizer and hydride generation with air addition.

    PubMed

    Zhang, B; Wang, Y; Wang, X; Chen, X; Feng, J

    1995-08-01

    A new method has been developed for the determination of antimony, arsenic, bismuth, selenium, tellurium and tin by hydride generation-atomic absorption spectrometry in an electrically heated quartz tube furnace under sub-atmospheric pressure. The hydride generator, operating at a pressure lower than atmospheric, is used to generate and collect the hydrides of these elements. A certain volume (at atmospheric pressure) of air is then added to the generator after the formation of the volatile hydride. The gaseous mixture of the hydride and air is drawn into an evacuated, heated quartz tube by a vacuum pump. The proposed method gives improved sensitivities and detection limits.

  1. Study of the roles of chemical modifiers in determining boron using graphite furnace atomic absorption spectrometry and optimization of the temperature profile during atomization.

    PubMed

    Yamamoto, Yuhei; Shirasaki, Toshihiro; Yonetani, Akira; Imai, Shoji

    2015-01-01

    The measurement conditions for determining boron using graphite furnace-atomic absorption spectrometry (GF-AAS) were investigated. Differences in the boron absorbance profiles were found using three different commercially available GF-AAS instruments when the graphite atomizers in them were not tuned. The boron absorbances found with and without adjusting the graphite atomizers suggested that achieving an adequate absorbance for the determination of boron requires a sharp temperature profile that overshoots the target temperature during the atomization process. Chemical modifiers that could improve the boron absorbance without the need for using coating agents were tested. Calcium carbonate improved the boron absorbance but did not suppress variability in the peak height. Improvement of boron absorbance was comparatively less using iron nitrate or copper nitrate than using calcium carbonate, but variability in the peak height was clearly suppressed using iron nitrate or copper nitrate. The limit of detection was 0.0026 mg L(-1) when iron nitrate was used. It appears that iron nitrate is a useful new chemical modifier for the quick and simple determination of boron using GF-AAS.

  2. Comparative determination of Ba, Cu, Fe, Pb and Zn in tea leaves by slurry sampling electrothermal atomic absorption and liquid sampling inductively coupled plasma atomic emission spectrometry.

    PubMed

    Mierzwa, J; Sun, Y C; Chung, Y T; Yang, M H

    1998-12-01

    The comparative determination of barium, copper, iron, lead and zinc in tea leaf samples by two atomic spectrometric techniques is reported. At first, slurry sampling electrothermal atomization atomic absorption spectrometry (ETAAS) was applied. The results of Ba and Pb determination were calculated using the method of standard additions, and results of Cu, Fe and Zn from the calibration graphs based on aqueous standards. These results were compared with the results obtained after microwave-assisted wet (nitric+hydrochloric+hydrofluoric acids) digestion in closed vessels followed by inductively coupled plasma-atomic emission spectrometric (ICP-AES) determination with the calibration by means of aqueous standards. The exception was lead determined after a wet digestion procedure by ETAAS. The accuracy of the studied methods was checked by the use of the certified reference material Tea GBW-07605. The recoveries of the analytes varied in the range from 91 to 99% for slurry sampling ETAAS, and from 92.5 to 102% for liquid sampling ICP-AES. The advantages of slurry sampling ETAAS method are simplicity of sample preparation and very good sensitivity. Slurry sampling ETAAS method is relatively fast but if several elements must be determined in one sample, the time of the whole microwave-assisted digestion procedure and ICP-AES determination will be shorter. However, worse detection limits of ICP-AES must also be taken into the consideration in a case of some analytes.

  3. Correlative atomic force and confocal fluorescence microscopy: single molecule imaging and force induced spectral shifts (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Basché, Thomas; Hinze, Gerald; Stöttinger, Sven

    2016-09-01

    A grand challenge in nanoscience is to correlate structure or morphology of individual nano-sized objects with their photo-physical properties. An early example have been measurements of the emission spectra and polarization of single semiconductor quantum dots as well as their crystallographic structure by a combination of confocal fluorescence microscopy and transmission electron microscopy.[1] Recently, the simultaneous use of confocal fluorescence and atomic force microscopy (AFM) has allowed for correlating the morphology/conformation of individual nanoparticle oligomers or molecules with their photo-physics.[2, 3] In particular, we have employed the tip of an AFM cantilever to apply compressive stress to single molecules adsorbed on a surface and follow the effect of the impact on the electronic states of the molecule by fluorescence spectroscopy.[3] Quantum mechanical calculations corroborate that the spectral changes induced by the localized force can be associated to transitions among the different possible conformers of the adsorbed molecule.

  4. Substituted benzoxadiazoles as fluorogenic probes: a computational study of absorption and fluorescence.

    PubMed

    Brown, Alex; Ngai, Tsz Yan; Barnes, Marie A; Key, Jessie A; Cairo, Christopher W

    2012-01-12

    General chemical strategies which provide controlled changes in the emission or absorption properties of biologically compatible fluorophores remain elusive. One strategy employed is the conversion of a fluorophore-attached alkyne (or azide) to a triazole through a copper-catalyzed azide-alkyne coupling (CuAAC) reaction. In this study, we have computationally examined a series of structurally related 2,1,3-benzoxadiazole (benzofurazan) fluorophores and evaluated changes in their photophysical properties upon conversion from alkyne (or azide) to triazole forms. We have also determined the photophysical properties for a known set of benzoxadiazole compounds. The absorption and emission energies have been determined computationally using time-dependent density functional theory (TD-DFT) with the Perdew, Burke, and Ernzerhof exchange-correlation density functional (PBE0) and the 6-31+G(d) basis set. The TD-DFT results consistently agreed with the experimentally determined absorption and emission wavelengths except for certain compounds where charge-transfer excited states occurred. In addition to determining the absorption and emission wavelengths, simple methods for predicting relative quantum yields previously derived from semiempirical calculations were reevaluated on the basis of the new TD-DFT results and shown to be deficient. These results provide a necessary framework for the design of new substituted benzoxadiazole fluorophores.

  5. Ultrafast Time-Resolved Emission and Absorption Spectra of meso-Pyridyl Porphyrins upon Soret Band Excitation Studied by Fluorescence Up-Conversion and Transient Absorption Spectroscopy.

    PubMed

    Venkatesh, Yeduru; Venkatesan, M; Ramakrishna, B; Bangal, Prakriti Ranjan

    2016-09-08

    A comprehensive study of ultrafast molecular relaxation processes of isomeric meso-(pyridyl) porphyrins (TpyPs) has been carried out by using femtosecond time-resolved emission and absorption spectroscopic techniques upon pumping at 400 nm, Soret band (B band or S2), in 4:1 dichloromethane (DCM) and tetrahydrofuran (THF) solvent mixture. By combined studies of fluorescence up-conversion, time-correlated single photon counting, and transient absorption spectroscopic techniques, a complete model with different microscopic rate constants associated with elementary processes involved in electronic manifolds has been reported. Besides, a distinct coherent nuclear wave packet motion in Qy state is observed at low-frequency mode, ca. 26 cm(-1) region. Fluorescence up-conversion studies constitute ultrafast time-resolved emission spectra (TRES) over the whole emission range (430-710 nm) starting from S2 state to Qx state via Qy state. Careful analysis of time profiles of up-converted signals at different emission wavelengths helps to reveal detail molecular dynamics. The observed lifetimes are as indicated: A very fast decay component with 80 ± 20 fs observed at ∼435 nm is assigned to the lifetime of S2 (B) state, whereas being a rise component in the region of between 550 and 710 nm emission wavelength pertaining to Qy and Qx states, it is attributed to very fast internal conversion (IC) occurring from B → Qy and B → Qx as well. Two distinct components of Qy emission decay with ∼200-300 fs and ∼1-1.5 ps time constants are due to intramolecular vibrational redistribution (IVR) induced by solute-solvent inelastic collisions and vibrational redistribution induced by solute-solvent elastic collision, respectively. The weighted average of these two decay components is assigned as the characteristic lifetime of Qy, and it ranges between 0.3 and 0.5 ps. An additional ∼20 ± 2 ps rise component is observed in Qx emission, and it is assigned to the formation time of

  6. A first principle study for the adsorption and absorption of carbon atom and the CO dissociation on Ir(100) surface

    SciTech Connect

    Erikat, I. A.; Hamad, B. A.

    2013-11-07

    We employ density functional theory to examine the adsorption and absorption of carbon atom as well as the dissociation of carbon monoxide on Ir(100) surface. We find that carbon atoms bind strongly with Ir(100) surface and prefer the high coordination hollow site for all coverages. In the case of 0.75 ML coverage of carbon, we obtain a bridging metal structure due to the balance between Ir–C and Ir–Ir interactions. In the subsurface region, the carbon atom prefers the octahedral site of Ir(100) surface. We find large diffusion barrier for carbon atom into Ir(100) surface (2.70 eV) due to the strong bonding between carbon atom and Ir(100) surface, whereas we find a very small segregation barrier (0.22 eV) from subsurface to the surface. The minimum energy path and energy barrier for the dissociation of CO on Ir(100) surface are obtained by using climbing image nudge elastic band. The energy barrier of CO dissociation on Ir(100) surface is found to be 3.01 eV, which is appreciably larger than the association energy (1.61 eV) of this molecule.

  7. Solvent effect on the absorption and fluorescence spectra of 7-acetoxy-6-(2,3-dibromopropyl)-4,8-dimethylcoumarin: determination of ground and excited state dipole moments.

    PubMed

    Gülseven Sıdır, Yadigar; Sıdır, Isa

    2013-02-01

    The ground state (μ(g)) and excited state (μ(e)) dipole moments of 7-acetoxy-6-(2,3-dibromopropyl)-4,8-dimethylcoumarin (abbreviated as 7ADDC) are estimated from solvatochromic shifts of absorption and fluorescence spectra as a function of the dielectric constant (ε) and refractive index (n). While the ground state dipole moment is determined by using Bilot-Kawski method, the excited state dipole moment is calculated by using Bilot-Kawski, Lippert-Mataga, Bakhshiev, Kawski-Chamma-Viallet and Reichardt correlation methods. Excited state dipole moment is observed as larger than the ground state dipole moment due to substantial π-electron density redistribution. The ground state and excited state dipole moments are observed as parallel to each other with angle of 0°. Solute-solvent interactions are analyzed by means of linear solvation free energy relationships (LSER) using dielectric constant function (f(ε)), refractive index function (f(n)) and Kamlet-Taft parameters (α and β). Atomic charges, electron densities and molecular orbitals are calculated in vacuum and with solvent effect by using both DFT and TDDFT methods. Solvent accessible surface, molecular electrostatic potential (MEP) and electrostatic potential (ESP) are visualized as a result of DFT calculations.

  8. Solvent effect on the absorption and fluorescence spectra of 7-acetoxy-6-(2,3-dibromopropyl)-4,8-dimethylcoumarin: Determination of ground and excited state dipole moments

    NASA Astrophysics Data System (ADS)

    Gülseven Sıdır, Yadigar; Sıdır, İsa

    2013-02-01

    The ground state (μg) and excited state (μe) dipole moments of 7-acetoxy-6-(2,3-dibromopropyl)-4,8-dimethylcoumarin (abbreviated as 7ADDC) are estimated from solvatochromic shifts of absorption and fluorescence spectra as a function of the dielectric constant (ɛ) and refractive index (n). While the ground state dipole moment is determined by using Bilot-Kawski method, the excited state dipole moment is calculated by using Bilot-Kawski, Lippert-Mataga, Bakhshiev, Kawski-Chamma-Viallet and Reichardt correlation methods. Excited state dipole moment is observed as larger than the ground state dipole moment due to substantial π-electron density redistribution. The ground state and excited state dipole moments are observed as parallel to each other with angle of 0°. Solute-solvent interactions are analyzed by means of linear solvation free energy relationships (LSER) using dielectric constant function (f(ɛ)), refractive index function (f(n)) and Kamlet-Taft parameters (α and β). Atomic charges, electron densities and molecular orbitals are calculated in vacuum and with solvent effect by using both DFT and TDDFT methods. Solvent accessible surface, molecular electrostatic potential (MEP) and electrostatic potential (ESP) are visualized as a result of DFT calculations.

  9. Determination of Ca, Mg, Na, Cd, Cu, Fe, K, Li and Zn in acid mine and reference water samples by inductively coupled plasma atomic fluorescence spectrometry

    USGS Publications Warehouse

    Sanzolone, R.F.; Meier, A.L.

    1986-01-01

    An inductively coupled plasma atomic fluorescence spectrometric (ICP-AFS) method was used for the determination of nine elements in natural water. Reference and acid mine water samples were analysed by this method to demonstrate its usefulness for hydrogeochemical exploration. The elements were determined in two groups based on the compatibility of operating conditions and consideration of element abundance levels in natural water. Ca, Mg and Na were determined as a group using one set of instrumental conditions and a 1 + 99 dilution of the sample, and Cd, Cu, Fe, K, Li and Zn were determined using another set of conditions and the undiluted sample. The detection limits for the elements are as follows: Ca, 1.4; Mg, 1.7; Na, 2.0; Cd, 1.8; Cu, 6.2; Fe, 15.8; K, 3.5; Li, 0.3; and Zn, 1.2 ng m1-1. Each element has a linear range spanning about four orders of magnitude. The method has good precision and accuracy, as shown by statistics on replicate analyses and by the agreement between values obtained and those recommended for the reference water samples, and also those obtained by atomic absorption spectrometry for the acid mine water samples.

  10. Assessment of homogeneity and minimum sample mass for cadmium analysis in powdered certified reference materials and real rice samples by solid sampling electrothermal vaporization atomic fluorescence spectrometry.

    PubMed

    Mao, Xuefei; Liu, Jixin; Huang, Yatao; Feng, Li; Zhang, Lihua; Tang, Xiaoyan; Zhou, Jian; Qian, Yongzhong; Wang, Min

    2013-01-30

    To optimize analytical quality controls of solid sampling electrothermal vaporization atomic fluorescence spectrometry (SS-ETV-AFS), the homogeneity (H(E)) of rice samples and their minimum sample mass (M) for cadmium analysis were evaluated using three certified reference materials (CRMs) and real rice samples. The effects of different grinding degrees (particle sizes <0.85, <0.25, <0.15, and >1 mm) on H(E) and M of real rice samples were also investigated. The calculated M values of three CRMs by the Pauwels equation were 2.19, 19.76, and 3.79 mg. The well-ground real rice samples (particle size <0.25 mm) demonstrated good homogeneity, and the M values were 3.48-4.27 mg. On the basis of these results, the Cd concentrations measured by the proposed method were compared with the results by microwave digestion graphite furnace atomic absorption spectrometry with a 0.5 g sample mass. There was no significant difference between these two methods, which meant that SS-ETV-AFS could be used to accurately detect Cd in rice with several milligrams of samples instead of the certified value (200 mg) or the recommended mass (200-500 mg) of the methods of the Association of Official Analytical Chemists.

  11. Imaging electronic trap states in perovskite thin films with combined fluorescence and femtosecond transient absorption microscopy

    DOE PAGES

    Xiao, Kai; Ma, Ying -Zhong; Simpson, Mary Jane; ...

    2016-04-22

    Charge carrier trapping degrades the performance of organometallic halide perovskite solar cells. To characterize the locations of electronic trap states in a heterogeneous photoactive layer, a spatially resolved approach is essential. Here, we report a comparative study on methylammonium lead tri-iodide perovskite thin films subject to different thermal annealing times using a combined photoluminescence (PL) and femtosecond transient absorption microscopy (TAM) approach to spatially map trap states. This approach coregisters the initially populated electronic excited states with the regions that recombine radiatively. Although the TAM images are relatively homogeneous for both samples, the corresponding PL images are highly structured. Themore » remarkable variation in the PL intensities as compared to transient absorption signal amplitude suggests spatially dependent PL quantum efficiency, indicative of trapping events. Furthermore, detailed analysis enables identification of two trapping regimes: a densely packed trapping region and a sparse trapping area that appear as unique spatial features in scaled PL maps.« less

  12. Imaging electronic trap states in perovskite thin films with combined fluorescence and femtosecond transient absorption microscopy

    SciTech Connect

    Xiao, Kai; Ma, Ying -Zhong; Simpson, Mary Jane; Doughty, Benjamin; Yang, Bin

    2016-04-22

    Charge carrier trapping degrades the performance of organometallic halide perovskite solar cells. To characterize the locations of electronic trap states in a heterogeneous photoactive layer, a spatially resolved approach is essential. Here, we report a comparative study on methylammonium lead tri-iodide perovskite thin films subject to different thermal annealing times using a combined photoluminescence (PL) and femtosecond transient absorption microscopy (TAM) approach to spatially map trap states. This approach coregisters the initially populated electronic excited states with the regions that recombine radiatively. Although the TAM images are relatively homogeneous for both samples, the corresponding PL images are highly structured. The remarkable variation in the PL intensities as compared to transient absorption signal amplitude suggests spatially dependent PL quantum efficiency, indicative of trapping events. Furthermore, detailed analysis enables identification of two trapping regimes: a densely packed trapping region and a sparse trapping area that appear as unique spatial features in scaled PL maps.

  13. Flow injection-chemical vapor generation atomic fluorescence spectrometry hyphenated system for organic mercury determination: A step forward

    NASA Astrophysics Data System (ADS)

    Angeli, Valeria; Biagi, Simona; Ghimenti, Silvia; Onor, Massimo; D'Ulivo, Alessandro; Bramanti, Emilia

    2011-11-01

    Monomethylmercury and ethylmercury were determined on line using flow injection-chemical vapor generation atomic fluorescence spectrometry without neither requiring a pre-treatment with chemical oxidants, nor UV/MW additional post column interface, nor organic solvents, nor complexing agents, such as cysteine. Inorganic mercury, monomethylmercury and ethylmercury were detected by atomic fluorescence spectrometry in an Ar/H 2 miniaturized flame after sodium borohydride reduction to Hg 0, monomethylmercury hydride and ethylmercury hydride, respectively. The effect of mercury complexing agent such as cysteine, ethylendiaminotetracetic acid and HCl with respect to water and Ar/H 2 microflame was investigated. The behavior of inorganic mercury, monomethylmercury and ethylmercury and their cysteine-complexes was also studied by continuous flow-chemical vapor generation atomic fluorescence spectrometry in order to characterize the reduction reaction with tetrahydroborate. When complexed with cysteine, inorganic mercury, monomethylmercury and ethylmercury cannot be separately quantified varying tetrahydroborate concentration due to a lack of selectivity, and their speciation requires a pre-separation stage (e.g. a chromatographic separation). If not complexed with cysteine, monomethylmercury and ethylmercury cannot be separated, as well, but their sum can be quantified separately with respect to inorganic mercury choosing a suitable concentration of tetrahydroborate (e.g. 10 - 5 mol L - 1 ), thus allowing the organic/inorganic mercury speciation. The detection limits of the flow injection-chemical vapor generation atomic fluorescence spectrometry method were about 45 nmol L - 1 (as mercury) for all the species considered, a relative standard deviation ranging between 1.8 and 2.9% and a linear dynamic range between 0.1 and 5 μmol L - 1 were obtained. Recoveries of monomethylmercury and ethylmercury with respect to inorganic mercury were never less than 91%. Flow injection

  14. Lead determination at ng/mL level by flame atomic absorption spectrometry using a tantalum coated slotted quartz tube atom trap.

    PubMed

    Demirtaş, İlknur; Bakırdere, Sezgin; Ataman, O Yavuz

    2015-06-01

    Flame atomic absorption spectrometry (FAAS) still keeps its importance despite the relatively low sensitivity; because it is a simple and economical technique for determination of metals. In recent years, atom traps have been developed to increase the sensitivity of FAAS. Although the detection limit of FAAS is only at the level of µg/mL, with the use of atom traps it can reach to ng/mL. Slotted quartz tube (SQT) is one of the atom traps used to improve sensitivity. In atom trapping mode of SQT, analyte is trapped on-line in SQT for few minutes using ordinary sample aspiration, followed by the introduction of a small volume of organic solvent to effect the revolatilization and atomization of analyte species resulting in a transient signal. This system is economical, commercially available and easy to use. In this study, a sensitive analytical method was developed for the determination of lead with the help of SQT atom trapping flame atomization (SQT-AT-FAAS). 574 Fold sensitivity enhancement was obtained at a sample suction rate of 3.9 mL/min for 5.0 min trapping period with respect to FAAS. Organic solvent was selected as 40 µL of methyl isobutyl ketone (MIBK). To obtain a further sensitivity enhancement inner surface of SQT was coated with several transition metals. The best sensitivity enhancement, 1650 fold enhancement, was obtained by the Ta-coated SQT-AT-FAAS. In addition, chemical nature of Pb species trapped on quartz and Ta surface, and the chemical nature of Ta on quartz surface were investigated by X-ray photoelectron spectroscopy (XPS) and Raman Spectroscopy. Raman spectrometric results indicate that tantalum is coated on SQT surface in the form of Ta2O5. XPS studies revealed that the oxidation state of Pb in species trapped on both bare and Ta coated SQT surfaces is +2. For the accuracy check, the analyses of standard reference material were performed by use of SCP SCIENCE EnviroMAT Low (EU-L-2) and results for Pb were to be in good agreement with

  15. Multi-Photon Absorption Spectra: A Comparison Between Transmittance Change and Fluorescence Methods

    DTIC Science & Technology

    2015-05-21

    AFRL-OSR-VA-TR-2015-0134 multi-photon absorption spectra Cleber Mendonca INSTITUTO DE FISICA DE SAO CARLOS Final Report 05/21/2015 DISTRIBUTION A...5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Instituto de Fisica de Sao Carlos - Universidade de Sao Paulo Av...Trabalhador Saocarlense 400 Sao Carlos, SP, 13566-590 Brazil 8. PERFORMING ORGANIZATION REPORT NUMBER Report 3 - Final 9. SPONSORING/MONITORING AGENCY

  16. Determination of cobalt in biological samples by line-source and high-resolution continuum source graphite furnace atomic absorption spectrometry using solid sampling or alkaline treatment

    NASA Astrophysics Data System (ADS)

    Ribeiro, Anderson Schwingel; Vieira, Mariana Antunes; da Silva, Alessandra Furtado; Borges, Daniel L. Gallindo; Welz, Bernhard; Heitmann, Uwe; Curtius, Adilson José

    2005-06-01

    Two procedures for the determination of Co in biological samples by graphite furnace atomic absorption spectrometry (GF AAS) were compared: solid sampling (SS) and alkaline treatment with tetramethylammonium hydroxide (TMAH) using two different instruments for the investigation: a conventional line-source (LS) atomic absorption spectrometer and a prototype high-resolution continuum source atomic absorption spectrometer. For the direct introduction of the solid samples, certified reference materials (CRM) were ground to a particle size ≤50 μm. Alkaline treatment was carried out by placing about 250 mg of the sample in polypropylene flasks, adding 2 mL of 25% m/v tetramethylammonium hydroxide and de-ionized water. Due to its unique capacity of providing a 3-D spectral plot, a high-resolution continuum source (HR-CS) graphite furnace atomic absorption spectrometry was used as a tool to evaluate potential spectral interferences, including background absorption for both sample introduction procedures, revealing that a continuous background preceded the atomic signal for pyrolysis temperatures lower than 700 °C. Molecular absorption bands with pronounced rotational fine structure appeared for atomization temperatures >1800 °C probably as a consequence of the formation of PO. After optimization had been carried out using high resolution continuum source atomic absorption spectrometry, the optimized conditions were adopted also for line-source atomic absorption spectrometry. Six biological certified reference materials were analyzed, with calibration against aqueous standards, resulting in agreement with the certified values (according to the t-test for a 95% confidence level) and in detection limits as low as 5 ng g -1.

  17. On the possibilities of high-resolution continuum source graphite furnace atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple atomic lines

    NASA Astrophysics Data System (ADS)

    Resano, M.; Rello, L.; Flórez, M.; Belarra, M. A.

    2011-05-01

    This paper explores the potential of commercially available high-resolution continuum source graphite furnace atomic absorption spectrometry instrumentation for the simultaneous or sequential monitoring of various atomic lines, in an attempt to highlight the analytical advantages that can be derived from this strategy. In particular, it is demonstrated how i) the monitoring of multiplets may allow for the simple expansion of the linear range, as shown for the measurement of Ni using the triplet located in the vicinity of 234.6 nm; ii) the use of a suitable internal standard may permit improving the precision and help in correcting for matrix-effects, as proved for the monitoring of Ni in different biological samples; iii) direct and multi-element analysis of solid samples may be feasible on some occasions, either by monitoring various atomic lines that are sufficiently close (truly simultaneous monitoring, as demonstrated in the determination of Co, Fe and Ni in NIST 1566a Oyster tissue) or, alternatively, by opting for a selective and sequential atomization of the elements of interest during every single replicate. Determination of Cd and Ni in BCR 679 White cabbage is attempted using both approaches, which permits confirming that both methods can offer very similar and satisfactory results. However, it is important to stress that the second approach provides more flexibility, since analysis is no longer limited to those elements that show very close atomic lines (closer than 0.3 nm in the ultraviolet region) with a sensitivity ratio similar to the concentration ratio of the analytes in the samples investigated.

  18. Enhanced two-photon absorption and fluorescence upconversion in Thioflavin T micelle-type aggregates in glycerol/water solution

    NASA Astrophysics Data System (ADS)

    Donnelly, Julie; Vesga, Yuly; Hernandez, Florencio E.

    2016-09-01

    In this article, we report the systematic characterization of the two-photon absorption of ThT in different mixtures of glycerol/water solution. The relationships of TPA peak position and amplitude revealed a dependence on particle size suggesting that the curious trend observed in TPA with changing glycerol content can be attributed to the presence of micelle-type aggregates. Consequently, the relatively strong TPA cross-section (δTPA = 300 GM) obtained in 8.75% glycerol/water solutions could be attributed to the immobilization of dye molecules and the strong coupling of the molecular transition dipoles in micelle-type aggregates. This enhancement of TPA, in addition to the already reported significant fluorescence quantum yield of ThT attached to brain tissue, is expected to boost the application of this compound for in vitro and perhaps in vivo high resolution multiphoton bioimaging of amyloids in brain tissue.

  19. Versatile plug flow catalytic cell for in situ transmission/fluorescence x-ray absorption fine structure measurements

    NASA Astrophysics Data System (ADS)

    Centomo, P.; Meneghini, C.; Zecca, M.

    2013-05-01

    A novel flow-through catalytic cell has been developed for in situ x-ray absorption spectroscopy (XAS) experiments on heterogeneous catalysts under working conditions and in the presence of a liquid and a gas phase. The apparatus allows to carry out XAS measurements in both the transmission and fluorescence modes, at moderate temperature (from RT to 50-80 °C) and low-medium gas pressure (up to 7-8 bars). The materials employed are compatible with several chemicals such as those involved in the direct synthesis of hydrogen peroxide (O2, H2, H2O2, methanol). The versatile design of the cell allows to fit it to different experimental setups in synchrotron radiation beamlines. It was used successfully for the first time to test nanostructured Pd catalysts during the direct synthesis of hydrogen peroxide (H2O2) in methanol solution from dihydrogen and dioxygen.

  20. Absorption and Luminescence Studies of Some Highly Fluorescent Derivatives of Vitamin B1; Solvent and pH Effects

    NASA Astrophysics Data System (ADS)

    Marciniak, B.; Koput, J.; Kozubek, H.

    1990-08-01

    The influence of solvent on the UV-visible absorption and luminescence spectra of some highly fluorescent vitamin B1 derivatives, the products of the reaction of N-methylated vitamin B1 with cytidine (I), adenosine (II) and 2-amino-4-methylpyridine (III) is studied. Spectroscopic manifestations of protonation of I and II are also investigated using a semiempirical INDO/S CI method. Singlet and triplet energy levels of the free ion and several protonated species are calculated, and transition energies and oscillator strengths are compared with the experimental spectra. Calculated charge densities on heteroatoms in the ground and excited singlet and triplet states are correlated with changes of the experimental pKa values with excitation. The results for I and II are compared with those for the trimethylated pyrichrominium ion (III) previously studied

  1. Excited-state intramolecular proton transfer of 2-acetylindan-1,3-dione studied by ultrafast absorption and fluorescence spectroscopy

    PubMed Central

    Verma, Pramod Kumar; Steinbacher, Andreas; Schmiedel, Alexander; Nuernberger, Patrick; Brixner, Tobias

    2015-01-01

    We employ transient absorption from the deep-UV to the visible region and fluorescence upconversion to investigate the photoinduced excited-state intramolecular proton-transfer dynamics in a biologically relevant drug molecule, 2-acetylindan-1,3-dione. The molecule is a ß-diketone which in the electronic ground state exists as exocyclic enol with an intramolecular H-bond. Upon electronic excitation at 300 nm, the first excited state of the exocyclic enol is initially populated, followed by ultrafast proton transfer (≈160 fs) to form the vibrationally hot endocyclic enol. Subsequently, solvent-induced vibrational relaxation takes place (≈10 ps) followed by decay (≈390 ps) to the corresponding ground state. PMID:26798837

  2. A new colorimetric and far-red fluorescent probe for hydrazine with a large red-shifted absorption spectrum.

    PubMed

    Xu, Zujun; Pang, Mengmeng; Li, Changwang; Zhu, Baocun

    2016-10-18

    Recently, growing attention has been paid to the detection of hydrazine (NH2 NH2 ) because of its important roles in industrial chemical and high toxicity to human beings. Herein, we have constructed a new colorimetric and far-red fluorescent probe containing a receptor of 4-bromobutanoate to selectively detect hydrazine. The probe could detect hydrazine quantitatively in the range of 40-500 μM with the detection limit of 2.9 μM. In addition, the probe could monitor hydrazine by the ratiometric method with a large (185 nm) red-shifted absorption spectrum, and the color changes from yellow to blue make it as a 'naked-eye' indicator for hydrazine. Consequently, our proposed probe would be of great benefit for monitoring hydrazine in aqueous solution.

  3. A comparison of simultaneous plasma, atomic absorption, and iron colorimetric determinations of major and trace constituents in acid mine waters

    USGS Publications Warehouse

    Ball, J.W.; Nordstrom, D.K.

    1994-01-01

    Sixty-three water samples collected during June to October 1982 from the Leviathan/Bryant Creek drainage basin were originally analyzed by simultaneous multielement direct-current plasma (DCP) atomic-emission spectrometry, flame atomic-absorption spectrometry, graphite-furnace atomic-absorption spectrometry (GFAAS) (thallium only), ultraviolet-visible spectrometry, and hydride-generation atomic-absorption spectrometry.Determinations were made for the following metallic and semi-metallic constituents: AI, As, B, Ba, Be, Bi, Cd, Ca, Cr, Co, Cu, Fe(11), Fe(total), Li, Pb, Mg, Mn, Mo, Ni, K, Sb, Se, Si, Na, Sr, TI, V, and Zn. These samples were re-analyzed later by simultaneous multielement inductively coupled plasma (ICP) atomic-emission spectrometry and Zeeman-corrected GFAAS to determine the concentrations of many of the same constituents with improved accuracy, precision, and sensitivity. The result of this analysis has been the generation of comparative concentration values for a significant subset of the solute constituents. Many of the more recently determined values replace less-than-detection values for the trace metals; others constitute duplicate analyses for the major constituents. The multiple determinations have yielded a more complete, accurate, and precise set of analytical data. They also have resulted in an opportunity to compare the performance of the plasma-emission instruments operated in their respective simultaneous multielement modes. Flame atomic-absorption spectrometry was judged best for Na and K and hydride-generation atomic-absorption spectrometry was judged best for As because of their lower detection limit and relative freedom from interelement spectral effects. Colorimetric determination using ferrozine as the color agent was judged most accurate, precise, and sensitive for Fe. Cadmium, lead, and vanadium concentrations were too low in this set of samples to enable a determination of whether ICP or DCP is a more suitable technique. Of

  4. Flame and graphite furnace atomic absorption spectrometry for trace element determination in vegetable oils, margarine and butter after sample emulsification.

    PubMed

    Ieggli, C V S; Bohrer, D; Do Nascimento, P C; De Carvalho, L M

    2011-05-01

    Trace element analysis plays an important role in oil characterisation and in the detection of oil adulteration because the quality of edible oils and fats is affected by their trace metal content. In this study, the quantification of selected metals in various oils and fats (rice oil, canola oil, sunflower oil, corn oil, soy oil, olive oil, light margarine, regular margarine and butter) was carried out using flame atomic absorption spectrometry (FAAS) and graphite furnace atomic absorption spectrometry (GFAAS) after sample emulsification. FAAS was used to determine the Na, K, Ca, Mg, Zn and Fe levels in the samples, while GFAAS was used for quantifying Cr, Ni, As, Pb, Cd, Cu and Mn, as these elements appeared in the samples at much lower concentrations. Tween-80 and Triton X-100 were employed as surfactants, and emulsions were prepared by a conventional method that involved heating and mixing of the constituents. Complete stabilisation was achieved through magnetic stirring for 15 min at room temperature. The evaluated figures of merit were linearity, accuracy and sensitivity, which were determined by the characteristic concentration and mass. Analysis of spiked samples demonstrated accuracy, which ranged from 90% (Na) to 112% (Fe) for FAAS and from 83% (Cd) to 121% (Pb) for GFAAS measurements. Atomic absorption spectrometry proved to be a promising approach for the analysis of metals in emulsified edible oils and fats. Additionally, under appropriate emulsification conditions (formulation, stirring time and temperature), the emulsions were homogeneous, had excellent stability, and had appropriate viscosity. The proposed method has proved to be simple, sensitive, reproducible, and economical.

  5. Determination of trace chromium in water by graphite furnace atomic absorption spectrophotometry after preconcentration on a soluble membrane filter

    SciTech Connect

    Gao Piying; Feng Ruolan; Zhang Huaizhu; Li Zhiqiang

    1998-04-01

    A new concentration and determination method has been described for the determination of lower than 0.1 {micro}g L{sup {minus}1} levels of chromium (VI) in water, based on the reaction between chromium (VI) and phenylfluorone (PF) to form an anionic chelate and the collection of the ternary ion-associate of the chelate with cetyltrimethylammonium bromide (CTMAB) (a cationic surfactant) on an organic solvent-soluble membrane filter. Determination of the solution obtained after dissolving the membrane and analyte in a suitable solvent is achieved using graphite furnace atomic absorption spectrophotometry. The ternary complex (Cr(VI)-PF-CTMAB = 1:2:2) is collected on a 0.45 {micro}m nitrocellulose filter and the filter and analyte are dissolved in a small volume of 2-methoxyethanol acidified with dilute sulfuric acid. The chromium is determined by graphite furnace atomic absorption spectrophotometry under optimum experimental conditions. A good linear relationship exists in the range 0.05--0.30 {micro}g chromium in 5.0 ml, with satisfactory reproducibility. The detection limit, defined as three times the standard deviation of the blank, is 0.06 {micro}g L{sup {minus}1} with 20 fold preconcentration. The ions normally present in water do not interfere under the experimental conditions used. The proposed method has been applied to the concentration and determination of chromium (VI) in water samples from several sources by means of direct graphic furnace atomic absorption spectrophotometry; the recoveries of chromium (VI) added to the samples are quantitative, and results found are satisfactory.

  6. Antimony in drinking water, red blood cells, and serum: development of analytical methodology using transversely heated graphite furnace atomization-atomic absorption spectrometry.

    PubMed

    Subramanian, K S; Poon, R; Chu, I; Connor, J W

    1997-05-01

    An atomic absorption spectrometric (AAS) method has been developed for determining microg/L levels of Sb in samples of water and blood. The AAS method is based on the concept of stabilized temperature platform furnace atomization (STPF) realized through the use of a transversely heated graphite atomizer (THGA) furnace, longitudinal Zeeman-effect background correction, and matrix modification with palladium nitrate-magnesium nitrate-nitric acid. The method of standard additions is not mandatory. The detection limit (3 standard deviations of the blank) is 2.6 microg Sb/L for the water, red blood cells (RBCs), and serum samples. Data are presented on the degree of accuracy and precision. The THGA-AAS method is simple, fast, and contamination-free because the entire operation from sampling to AAS measurement is carried out in the same tube. The method has been applied to the determination of Sb in some leachate tap water samples derived from a static copper plumbing system containing Sn/Sb solders, and in small samples (0.5 ml) of RBCs and serum derived from rats given Sb-supplemented drinking water.

  7. Optimization of a hydride generation metallic furnace atomic absorption spectrometry (HG-MF-AAS) method for tin determination: analytical and morphological parameters of a metallic atomizer.

    PubMed

    Moretto Galazzi, Rodrigo; Arruda, Marco Aurélio Zezzi

    2013-12-15

    The present work describes a metallic tube as hydride atomizer for atomic absorption spectrometry. Its performance is evaluated through tin determination, and the accuracy of the method assessed through the analysis of sediment and water samples. Some chemical parameters (referring to the generation of the hydride) such as acid, NaOH and THB concentrations, as well as physical parameters (referring to the transport of the hydride) such as carrier, acetylene, air flow-rates, flame composition, coil length, tube hole area, among others, are evaluated for optimization of the method. Scanning electron microscopy is used for evaluating morphological parameters in both new and used (after 150 h) tube atomizers. The method presents linear Sn concentration from 50 to 1000 µg L(-1) (r>0.9995; n=3) and the analytical frequency of ca. 40 h(-1). The limit of detection (LOD) is 7.1 µg L(-1) and the precision, expressed as RSD is less than 4% (200 µg L(-1); n=10). The accuracy is evaluated through reference materials, and the results are similar at 95% confidence level according to the t-test.

  8. An atomic absorption spectrophotometric method for the determination of trace amounts of zinc in canned juices after ion exchange separation.

    PubMed

    Aziz-Alrahman, A M

    1984-01-01

    An atomic absorption spectrophotometric method is described for the determination of microgram quantities of zinc in canned juices. After sample digestion in concentrated nitric acid, the solution is evaporated till near dryness, and then a solution of 2 M HCl is added to form tetrachlorozincate (II) ion. This acid solution, containing the zinc complex is passed through an ion-exchange column (anion exchange resin, chloride form, which is preconditioned by passing 1 M HCl solution). Zinc is eluted from the column with 0.01 M HCl solution. After evaporation to dryness, the residue is dissolved in 1% (v/v) HNO3, and then atomized into an air-acetylene flame. The limit of detection of the method is 0.15 micrograms ml-1 Zn. The analytical aspects of the proposed method, including the standard addition technique are discussed.

  9. Determination of bismuth in environmental samples by slurry sampling graphite furnace atomic absorption spectrometry using combined chemical modifiers.

    PubMed

    Dobrowolski, Ryszard; Dobrzyńska, Joanna; Gawrońska, Barbara

    2015-01-01

    Slurry sampling graphite furnace atomic absorption spectrometry technique was applied for the determination of Bi in environmental samples. The study focused on the effect of Zr, Ti, Nb and W carbides, as permanent modifiers, on the Bi signal. Because of its highest thermal and chemical stability and ability to substantially increase Bi signal, NbC was chosen as the most effective modifier. The temperature programme applied for Bi determination was optimized based on the pyrolysis and atomization curves obtained for slurries prepared from certified reference materials (CRMs) of the soil and sediments. To overcome interferences caused by sulfur compounds, Ba(NO₃)₂ was used as a chemical modifier. Calibration was performed using the aqueous standard solutions. The analysis of the CRMs confirmed the reliability of the proposed analytical method. The characteristic mass for Bi was determined to be 16 pg with the detection limit of 50 ng/g for the optimized procedure at the 5% (w/v) slurry concentration.

  10. Microwave-assisted extraction and ultrasonic slurry sampling procedures for cobalt determination in geological samples by electrothermal atomic absorption spectroscopy.

    PubMed

    Felipe-Sotelo, M; Carlosena, A; Fernández, E; López-Mahía, P; Muniategui, S; Prada, D

    2004-06-17

    Slurry sampling is compared to microwave-assisted acid digestion for cobalt determination in soil/sediment samples by electrothermal atomic absorption spectrometry (ETAAS). Furnace temperature programs and appropriate amounts of three chemical modifiers were optimised in order to get the highest signals and good separations between the atomic and background signals. Using nitric acid (0.5% (v/v)) as liquid medium, no chemical modifier was needed. The detection limit, based on integrated absorbance, was 0.04mugg(-1) for digests and slurries. Within-batch precision and analytical recoveries were satisfactory for both procedures. Accuracy was tested by analysing a reference soil and a sediment from IRMM. The methods were further compared employing a set of roadside soils and estuarine sediments. As no significant differences (95% confidence) were found, practical analytical properties were suggested in order to select one of them.

  11. Determination of cadmium by electrothermal atomic absorption spectrometry after microwave-assisted digestion of animal tissues and sewage sludges.

    PubMed

    Chakraborty, R; Das, A K; Cervera, M L; De La Guardia, M

    1996-04-01

    The determination of cadmium in different sample types has been carried out by electrothermal atomization atomic absorption spectrometry with D(2)-background correction using a unpyrocoated graphite tube, after pressurized microwave-assisted digestion. Five chemical modifiers [(NH(4))(2)HPO(4), Pd(NO)(3))(2), Ni(NO(3))(2), thiourea and Triton X-100] have been assayed and nickel nitrate has been found to be most effective for an accurate determination of cadmium in mussel tissue, pig kidney and sewage sludge. The characteristic mass of the method is of the order of 1 pg and the limit of detection is lower than 0.1 ng/ml.

  12. Speciation of methyl- and butyltin compounds and inorganic tin in oysters by hydride generation atomic absorption spectrometry

    SciTech Connect

    Han, J.S.; Weber, J.H.

    1988-02-15

    Because of the toxicity of tributyltin originating from many antifouling marine paints, there is much concern about its effect on aquatic life and, particularly, on shellfish. This paper describes speciation of inorganic tin, methyltin compounds, and butyltin compounds from oyster samples. The authors validated the hydride generation atomic absorption spectrophotometric technique by demonstrating ca. 100% recovery from spiked samples and by the absence of any organotin decomposition products. Absolute detection limits (3sigma) are 1.1-2.5 ng for 0.1-g oyster samples (wet weight). This method is superior to published techniques because of careful validation, low limits of detection, and minimal sample manipulation.

  13. New method for determining relative oscillator strengths of atoms through combined absorption and emission measurements - Application to titanium /Ti I/

    NASA Technical Reports Server (NTRS)

    Cardon, B. L.; Smith, P. L.; Whaling, W.

    1979-01-01

    The paper introduces a procedure that combines measurements of absorption and emission by atoms to obtain relative oscillator strengths that are independent of temperature determination in the sources and of assumptions regarding local thermodynamic equilibrium. The experimental observations are formed into sets of transitions and required to satisfy defined ratios. The procedure is illustrated with the published data of Whaling et al. and Smith and Kuehne for 16 transitions in Ti I. It is shown that the relative oscillator strengths resulting from this procedure have calculated uncertainties between 5 and 17% (about 95% confidence level). Evidence is presented to suggest that these uncertainties have been overestimated.

  14. Optimisation of flame parameters for simultaneous multi-element atomic absorption spectrometric determination of trace elements in rocks

    USGS Publications Warehouse

    Kane, J.S.

    1988-01-01

    A study is described that identifies the optimum operating conditions for the accurate determination of Co, Cu, Mn, Ni, Pb, Zn, Ag, Bi and Cd using simultaneous multi-element atomic absorption spectrometry. Accuracy was measured in terms of the percentage recoveries of the analytes based on certified values in nine standard reference materials. In addition to identifying optimum operating conditions for accurate analysis, conditions resulting in serious matrix interferences and the magnitude of the interferences were determined. The listed elements can be measured with acceptable accuracy in a lean to stoicheiometric flame at measurement heights ???5-10 mm above the burner.

  15. An abbreviated fire-assay atomic-absorption method for the determination of gold and silver in ores and concentrates.

    PubMed

    Moloughney, P E

    1977-02-01

    A simplified scheme, combining aspects of the classical fire-assay with an atomic-absorption finish, is presented for the determination of gold and silver in ores and concentrates. The lead assay button is scorified to approximately 2 g and then parted in nitric acid. The filtrate is analysed by AAS for silver; the residue is dissolved in aqua regia and subsequently analysed for gold by AAS. The precision and accuracy of the method have been established by application to four diverse certified reference materials. The proposed method eliminates the need for such time-consuming steps as inquartation, multiple scorifications, and cupellation.

  16. Determination of silver in soils, sediments, and rocks by organic-chelate extraction and atomic absorption spectrophotometry

    USGS Publications Warehouse

    Chao, T.T.; Ball, J.W.; Nakagawa, H.M.

    1971-01-01

    A useful method for the determination of silver in soil, sediment, and rock samples in geochemical exploration has been developed. The sample is digested with concentrated nitric acid, and the silver extracted with triisooctyl thiophosphate (TOTP) in methyl isobutyl ketone (MIBK) after dilution of the acid digest to approximately 6 M. The extraction of silver into the organic extractant is quantitative and not affected by the nitric acid concentration from 4 M to 8 M, or by different volumes of TOTP-MIBK. The extracted silver is stable and remains in the organic phase up to several days. The silver concentration is determined by atomic absorption spectrophotometry. ?? 1971.

  17. A photon counting and a squeezing measurement method by the exact absorption and dispersion spectrum of Λ-type Atoms.

    PubMed

    Naeimi, Ghasem; Alipour, Samira; Khademi, Siamak

    2016-01-01

    Recently, the master equations for the interaction of two-mode photons with a three-level Λ-type atom are exactly solved for the coherence terms. In this paper the exact absorption spectrum is applied for the presentation of a non-demolition photon counting method, for a few number of coupling photons, and its benefits are discussed. The exact scheme is also applied where the coupling photons are squeezed and the photon counting method is also developed for the measurement of the squeezing parameter of the coupling photons.

  18. Determination of nickel in the serum of occupationally exposed workers, by means of flame atomic-absorption spectroscopy.

    PubMed

    Ghe, A M; Lippolis, M T; Pastorelli, L

    1985-10-01

    A flame atomic-absorption spectroscopy method for determination of nickel in the serum of occupationally exposed subjects has been developed. Trichloroacetic add is utilized for precipitating proteins and freeing bound nickel; sodium diethyldithiocarbamate is used as complexing agent and isopropyl acetate as the solvent for extraction. The method is characterized by good accuracy, precision and sensitivity, over a concentration range up to about 20 ng/ml. Calcium, which is present in serum in great excess with respect to typical nickel concentrations, does not interfere in the determination of the latter.

  19. [Determination of Pb and Al in blood and hair of child using transverse heated graphite furnace atomic absorption spectroscopy].

    PubMed

    Niu, Feng-lan; Xie, Wen-bing; Li, Chen-xu; Dong, Wei-yan

    2005-04-01

    Pb and Al in blood and hair of child were determined by transverse heated graphite furnace atomic absorption spectrometry with NH4H2PO4 and Mg(NO3)2 as a modifier, which enhanced the temperature of ashing, eliminated the matrix interference and memorial effect. The method is rapid, simple and accurate. The characteristic mass of the method was 2.3 x 10(-11) g and 2.2 x 10(-11) g for Pb and Al respectively. The relative standard deviation of Pb and Al was 3.0% and 11.4%, respectively, and the recovery was 96%-102%.

  20. Graphite furnace atomic absorption spectrophotometry--a novel method to quantify blood volume in experimental models of intracerebral hemorrhage.

    PubMed

    Kashefiolasl, Sepide; Foerch, Christian; Pfeilschifter, Waltraud

    2013-02-15

    Intracerebral hemorrhage (ICH) accounts for 10% of all strokes and has a significantly higher mortality than cerebral ischemia. For decades, ICH has been neglected by experimental stroke researchers. Recently, however, clinical trials on acute blood pressure lowering or hyperacute supplementation of coagulation factors in ICH have spurred an interest to also design and improve translational animal models of spontaneous and anticoagulant-associated ICH. Hematoma volume is a substantial outcome parameter of most experimental ICH studies. We present graphite furnace atomic absorption spectrophotometric analysis (AAS) as a suitable method to precisely quantify hematoma volumes in rodent models of ICH.