Science.gov

Sample records for absorption spectrometry hg-aas

  1. COMPREHENSIVE ANALYSIS OF BIOLOGICALLY RELEVANT ARSENICALS BY PH-SELECTIVE HYDRIDE GENERATION-ATOMIC ABSORPTION SPECTROMETRY

    EPA Science Inventory


    A method based on pH-selective generation and separation of arsines is commonly used for analysis of inorganic, methylated, and dimethylated trivalent and pentavalent arsenicals by hydride generation-atomic absorption spectrometry (HG-AAS). We have optimized this method to pe...

  2. SPE HG-AAS method for the determination of inorganic arsenic in rice--results from method validation studies and a survey on rice products.

    PubMed

    Rasmussen, Rie R; Qian, Yiting; Sloth, Jens J

    2013-09-01

    The present paper describes the development, validation and application of a method for inorganic arsenic (iAs) determination in rice samples. The separation of iAs from organoarsenic compounds was done by off-line solid-phase extraction (SPE) followed by hydride generation atomic absorption spectrometry (HG-AAS) detection. This approach was earlier developed for seafood samples (Rasmussen et al., Anal Bioanal Chem 403:2825-2834, 2012) and has in the present work been tailored for rice products and further optimised for a higher sample throughput and a lower detection limit. Water bath heating (90 °C, 60 min) of samples with dilute HNO3 and H2O2 solubilised and oxidised all iAs to arsenate (As(V)). Loading of buffered sample extracts (pH 6 ± 1) followed by selective elution of arsenate from a strong anion exchange SPE cartridge enabled the selective iAs quantification by HG-AAS, measuring total arsenic (As) in the SPE eluate. The in-house validation gave mean recoveries of 101-106% for spiked rice samples and in two reference samples. The limit of detection was 0.02 mg kg(-1), and repeatability and intra-laboratory reproducibility were less than 6 and 9%, respectively. The SPE HG-AAS method produced similar results compared to parallel high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (ICP-MS) analysis. The SPE separation step was tested collaboratively, where the laboratories (N = 10) used either HG-AAS or ICP-MS for iAs determination in a wholemeal rice powder. The trial gave satisfactory results (HorRat value of 1.6) and did not reveal significant difference (t test, p > 0.05) between HG-AAS and ICP-MS quantification. The iAs concentration in 36 rice samples purchased on the Danish retail market varied (0.03-0.60 mg kg(-1)), with the highest concentration found in a red rice sample.

  3. Automated method for the determination of total arsenic and selenium in natural and drinking water by HG-AAS.

    PubMed

    Pistón, Mariela; Silva, Javier; Pérez-Zambra, Ramiro; Dol, Isabel; Knochen, Moisés

    2012-04-01

    A multicommutated flow system was designed and evaluated for the determination of total arsenic and selenium by Hydride Generation Atomic Absorption Spectrometry (HG-AAS). It was applied to the determination of arsenic and selenium in samples of natural and drinking water. Detection limits were 0.46 and 0.08 μg l(-1) for arsenic and selenium, respectively; sampling frequency was 120 samples h(-1) for arsenic and 160 samples h(-1) for selenium. Linear ranges found were 1.54-10 μg l(-1) (R = 0.999) for arsenic and 0.27-27 μg l(-1) (R = 0.999) for selenium. Accuracy was evaluated by spiking various water samples and using a reference material. Recoveries were in the range 95-116%. Analytical precision (s ( r ) (%), n = 10) was 6% for both elements. Compared with the Standard Methods, APHA, 3114B manual method, the system consumes at least 10 times less sample per determination, and the quantities of acid and reducing agent used are significantly lower with a reduction in the generation of pollutants and waste. As an additional advantage, the system is very fast, efficient and environmentally friendly for monitoring total arsenic and selenium levels in waters.

  4. Ultraviolet and Light Absorption Spectrometry.

    ERIC Educational Resources Information Center

    Hargis, L. G.; Howell, J. A.

    1984-01-01

    Reviews developments in ultraviolet and light absorption spectrometry from December 1981 through November 1983, focusing on the chemistry involved in developing suitable reagents, absorbing systems, and methods of determination, and on physical aspects of the procedures. Includes lists of spectrophotometric methods for metals, non-metals, and…

  5. Comparison of selenium determination in liver samples by atomic absorption spectroscopy and inductively coupled plasma-mass spectrometry.

    PubMed

    Miksa, Irina Rudik; Buckley, Carol L; Carpenter, Nancy P; Poppenga, Robert H

    2005-07-01

    Selenium (Se) is an essential trace element that is often deficient in the natural diets of domestic animal species. The measurement of Se in whole blood or liver is the most accurate way to assess Se status for diagnostic purposes. This study was conducted to compare hydride generation atomic absorption spectroscopy (HG-AAS) with inductively coupled plasma-mass spectrometry (ICP-MS) for the detection and quantification of Se in liver samples. Sample digestion was accomplished with magnesium nitrate and nitric acid for HG-AAS and ICP-MS, respectively. The ICP-MS detection was optimized for 82Se with yttrium used as the internal standard and resulted in a method detection limit of 0.12 microg/g. Selenium was quantified by both methods in 310 samples from a variety of species that were submitted to the Toxicology Laboratory at New Bolton Center (Kennett Square, PA) for routine diagnostic testing. Paired measurements for each sample were evaluated by a mean difference plot method. Limits of agreement were used to describe the maximum differences likely to occur between the 2 methods. Results suggest that under the specified conditions ICP-MS can be reliably used in place of AAS for quantitation of tissue Se at or below 2 microg/g to differentiate between adequate and deficient liver Se concentrations.

  6. Arsenic speciation in natural water samples by coprecipitation-hydride generation atomic absorption spectrometry combination.

    PubMed

    Tuzen, Mustafa; Citak, Demirhan; Mendil, Durali; Soylak, Mustafa

    2009-04-15

    A speciation procedure for As(III) and As(V) ions in environmental samples has been presented. As(V) was quantitatively recovered on aluminum hydroxide precipitate. After oxidation of As(III) by using dilute KMnO(4), the developed coprecipitation was applied to determination of total arsenic. Arsenic(III) was calculated as the difference between the total arsenic content and As(V) content. The determination of arsenic levels was performed by hydride generation atomic absorption spectrometry (HG-AAS). The analytical conditions for the quantitative recoveries of As(V) including pH, amount of aluminum as carrier element and sample volume, etc. on the presented coprecipitation system were investigated. The effects of some alkaline, earth alkaline, metal ions and also some anions were also examined. Preconcentration factor was calculated as 25. The detection limits (LOD) based on three times sigma of the blank (N: 21) for As(V) was 0.012 microg L(-1). The satisfactory results for the analysis of arsenic in NIST SRM 2711 Montana soil and LGC 6010 Hard drinking water certified reference materials for the validation of the method was obtained. The presented procedure was successfully applied to real samples including natural waters for arsenic speciation.

  7. Absorption mode FTICR mass spectrometry imaging.

    PubMed

    Smith, Donald F; Kilgour, David P A; Konijnenburg, Marco; O'Connor, Peter B; Heeren, Ron M A

    2013-12-03

    Fourier transform ion cyclotron resonance mass spectrometry offers the highest mass resolving power for molecular imaging experiments. This high mass resolving power ensures that closely spaced peaks at the same nominal mass are resolved for proper image generation. Typically higher magnetic fields are used to increase mass resolving power. However, a gain in mass resolving power can also be realized by phase correction of the data for absorption mode display. In addition to mass resolving power, absorption mode offers higher mass accuracy and signal-to-noise ratio over the conventional magnitude mode. Here, we present the first use of absorption mode for Fourier transform ion cyclotron resonance mass spectrometry imaging. The Autophaser algorithm is used to phase correct each spectrum (pixel) in the image, and then, these parameters are used by the Chameleon work-flow based data processing software to generate absorption mode "Datacubes" for image and spectral viewing. Absorption mode reveals new mass and spatial features that are not resolved in magnitude mode and results in improved selected ion image contrast.

  8. Analysis of metals in marine sediments by microwave extraction and flame, hydride generation and cold vapor atomic-absorption spectrometry

    SciTech Connect

    Martinez-Garcia, M.L.; Zubieta, A.C.; Lorenzo, S.M.; Lopez-Mahia, P.; Rodriguez, D.P.

    1999-01-01

    A simple and fast metal extraction method that combines closed vessels and microwave heating for the simultaneous extraction of ten selected heavy metals (As, Cd, Co, Cr, Hg, Mn, Ni, Pb, Zn) from marine sediments is proposed. Digestion conditions, i.e., power and times microwave irradiation, reagent extractant, sample amount, were optimized to recover the potentially available metallic fraction not bound in silicates. A nitric acid and two step microwave program was established. The resulting solutions were analyzed by flame (FAAS), hydride generation (HG-AAS) and cold vapor (CV-AAS) atomic absorption spectrometry. Quantifications were made using direct calibration with aqueous standards. The recoveries of the spiked samples investigated ranged from 89 to 113%. The results obtained from analyzing the BCR certified reference sediment CRM 277 Estuarine Sediment were in good agreement with the certified values (93--105%), except for low values for chromium (79%). The relative standard deviations for the determination of metals were less than 4%. Finally, the technique designed herein was applied to sediment samples from La Coruna estuary, NW Spain.

  9. Minimization of volatile nitrogen oxides interference in the determination of arsenic by hydride generation atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    de Moraes Flores, Érico Marlon; da Silva, Letícia Longhi Cirne; Barin, Juliano Smanioto; Saidelles, Ana Paula Fleig; Zanella, Renato; Dressler, Valderi Luis; Paniz, José Neri Gottfried

    2001-10-01

    In this study emphasis was given to minimize the interference of volatile nitrogen oxides from digestion procedures with nitric acid on the determination of arsenic by hydride generation atomic absorption spectrometry (HG AAS). Sulfamic acid (SA) is proposed to minimize this interference by employing three procedures for the digestion of hair in closed systems: conventional and microwave (MW) heating in polytetrafluorethylene (PTFE) vessels and by MW heating in glass vials. Hair samples were digested with H 2SO 4+HNO 3 or HNO 3+H 2O 2 mixtures. Concentrated hydrochloric acid was added for the digestion for the procedure in glass vials. The accuracy of the procedures with PTFE vessels was verified by the spike recoveries of organic ( p-aminobenzenearsonic acid and dimethyl arsinic acid, from 92 to 101%) and inorganic (sodium arsenate, from 98 to 102%) arsenic compounds. For the procedure in glass vials the recovery was from 86 to 97% for organic As and from 97 to 102% for inorganic As. The results obtained for a certified hair reference material using the three digestion procedures were well within the 95% confidence interval of the certificate when SA was added to the solutions. However, when SA was not added, recoveries were low and non-reproducible signals and high background levels were observed. Urea, benzoic acid and hydroxylamine hydrochloride were also studied (maximum As recovery of 90% using hydroxylamine hydrochloride) but the best results were obtained with use of SA.

  10. Graphite filter atomizer in atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Katskov, Dmitri A.

    2007-09-01

    Graphite filter atomizers (GFA) for electrothermal atomic absorption spectrometry (ETAAS) show substantial advantages over commonly employed electrothermal vaporizers and atomizers, tube and platform furnaces, for direct determination of high and medium volatility elements in matrices associated with strong spectral and chemical interferences. Two factors provide lower limits of detection and shorter determination cycles with the GFA: the vaporization area in the GFA is separated from the absorption volume by a porous graphite partition; the sample is distributed over a large surface of a collector in the vaporization area. These factors convert the GFA into an efficient chemical reactor. The research concerning the GFA concept, technique and analytical methodology, carried out mainly in the author's laboratory in Russia and South Africa, is reviewed. Examples of analytical applications of the GFA in AAS for analysis of organic liquids and slurries, bio-samples and food products are given. Future prospects for the GFA are discussed in connection with analyses by fast multi-element AAS.

  11. Accuracy of a method based on atomic absorption spectrometry to determine inorganic arsenic in food: Outcome of the collaborative trial IMEP-41.

    PubMed

    Fiamegkos, I; Cordeiro, F; Robouch, P; Vélez, D; Devesa, V; Raber, G; Sloth, J J; Rasmussen, R R; Llorente-Mirandes, T; Lopez-Sanchez, J F; Rubio, R; Cubadda, F; D'Amato, M; Feldmann, J; Raab, A; Emteborg, H; de la Calle, M B

    2016-12-15

    A collaborative trial was conducted to determine the performance characteristics of an analytical method for the quantification of inorganic arsenic (iAs) in food. The method is based on (i) solubilisation of the protein matrix with concentrated hydrochloric acid to denature proteins and allow the release of all arsenic species into solution, and (ii) subsequent extraction of the inorganic arsenic present in the acid medium using chloroform followed by back-extraction to acidic medium. The final detection and quantification is done by flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS). The seven test items used in this exercise were reference materials covering a broad range of matrices: mussels, cabbage, seaweed (hijiki), fish protein, rice, wheat, mushrooms, with concentrations ranging from 0.074 to 7.55mgkg(-1). The relative standard deviation for repeatability (RSDr) ranged from 4.1 to 10.3%, while the relative standard deviation for reproducibility (RSDR) ranged from 6.1 to 22.8%.

  12. Atomic Absorption, Atomic Fluorescence, and Flame Emission Spectrometry.

    ERIC Educational Resources Information Center

    Horlick, Gary

    1984-01-01

    This review is presented in six sections. Sections focus on literature related to: (1) developments in instrumentation, measurement techniques, and procedures; (2) performance studies of flames and electrothermal atomizers; (3) applications of atomic absorption spectrometry; (4) analytical comparisons; (5) atomic fluorescence spectrometry; and (6)…

  13. Determination of lead in wine and rum samples by flow injection-hydride generation-atomic absorption spectrometry.

    PubMed

    Elçi, Latif; Arslan, Zikri; Tyson, Julian F

    2009-03-15

    A method for direct determination of lead in wine and rum samples was developed, using a flow injection hydride generation system coupled to an atomic absorption spectrometer with flame-quartz atomizer (FI-HG-AAS). Lead hyride (PbH(4)) was generated using potassium ferricyanide (K(3)Fe(CN)(6)), as oxidant and sodium tetrahydroborate (NaBH(4)) as reductant. Samples were acidified to 0.40% (v/v) HCl for wine and to 0.30% (v/v) HCl for rum, which were then mixed on-line with 3% (m/v) K(3)Fe(CN)(6) solution in 0.03% (v/v) HCl prior to reaction with 0.2% (m/v) alkaline NaBH(4) solution. Lead contents of a rum and two different red wine samples were determined by FI-HG-AAS agreed with those obtained by ICP-MS. The analytical figures of merit of method developed were determined. The calibration curve was linear up to 8.0 microg L(-1) Pb with a regression coefficient of 0.998. The relative error was lower than 4.58%. The relative standard deviation (n=7) was better than 12%. A detection limit of 0.16 microg L(-1) was achieved for a sample volume of 170 microL.

  14. Absorption Mode FT-ICR Mass Spectrometry Imaging

    SciTech Connect

    Smith, Donald F.; Kilgour, David P.; Konijnenburg, Marco; O'Connor, Peter B.; Heeren, Ronald M.

    2013-12-03

    Fourier transform ion cyclotron resonance mass spectrometry offers the highest mass resolving power for molecular imaging experiments. This high mass resolving power ensures that closely spaced peaks at the same nominal mass are resolved for proper image generation. Typically higher magnetic fields are used to increase mass resolving power. However, a gain in mass resolving power can also be realized by phase correction of the data for absorption mode display. In addition to mass resolving power, absorption mode offers higher mass accuracy and signal-to-noise ratio over the conventional magnitude mode. Here we present the first use of absorption mode for Fourier transform ion cyclotron resonance mass spectrometry imaging. The Autophaser algorithm is used to phase correct each spectrum (pixel) in the image and then these parameters are used by the Chameleon work-flow based data processing software to generate absorption mode ?Datacubes? for image and spectral viewing. Absorption mode reveals new mass and spatial features that are not resolved in magnitude mode and results in improved selected ion image contrast.

  15. [Application of atomic absorption spectrometry in the engine knock detection].

    PubMed

    Chen, Li-Dan

    2013-02-01

    Because existing human experience diagnosis method and apparatus for auxiliary diagnosis method are difficult to diagnose quickly engine knock. Atomic absorption spectrometry was used to detect the automobile engine knock in in innovative way. After having determined Fe, Al, Cu, Cr and Pb content in the 35 groups of Audi A6 engine oil whose travel course is 2 000 -70 000 kilometers and whose sampling interval is 2 000 kilometers by atomic absorption spectrometry, the database of primary metal content in the same automobile engine at different mileage was established. The research shows that the main metal content fluctuates within a certain range. In practical engineering applications, after the determination of engine oil main metal content and comparison with its database value, it can not only help to diagnose the type and location of engine knock without the disintegration and reduce vehicle maintenance costs and improve the accuracy of engine knock fault diagnosis.

  16. Simultaneous Atomic Absorption Spectrometry for Cadmium and Lead Determination in Wastewater: A Laboratory Exercise

    ERIC Educational Resources Information Center

    Correia, Paulo R. M.; Oliveira, Pedro V.

    2004-01-01

    The simultaneous determination of cadmium and lead by multi-element atomic absorption spectrometry with electrochemical atomization is proposed by employing a problem-based approach. The reports indicate that the students assimilated the principles of the simultaneous atomic absorption spectrometry (SIMAAS), the role of the chemical modifier, the…

  17. Determination of mercury in hair: Comparison between gold amalgamation-atomic absorption spectrometry and mass spectrometry.

    PubMed

    Domanico, Francesco; Forte, Giovanni; Majorani, Costanza; Senofonte, Oreste; Petrucci, Francesco; Pezzi, Vincenzo; Alimonti, Alessandro

    2016-09-29

    Mercury is a heavy metal that causes serious health problems in exposed subjects. The most toxic form, i.e., methylmercury (MeHg), is mostly excreted through human hair. Numerous analytical methods are available for total Hg analysis in human hair, including cold vapour atomic fluorescence spectrometry (CV-AFS), inductively coupled plasma mass spectrometry (ICP-MS) and thermal decomposition amalgamation atomic absorption spectrometry (TDA-AAS). The aim of the study was to compare the TDA-AAS with the ICP-MS in the Hg quantification in human hair. After the washing procedure to minimize the external contamination, from each hair sample two aliquots were taken; the first was used for direct analysis of Hg by TDA-AAS and the second was digested for Hg determination by the ICP-MS. Results indicated that the two data sets were fully comparable (median; TDA-AAS, 475ngg(-1); ICP-MS, 437ngg(-1)) and were not statistically different (Mann-Whitney test; p=0.44). The two techniques presented results with a good coefficient of correlation (r=0.94) despite different operative ranges and method limits. Both techniques satisfied internal performance requirements and the parameters for method validation resulting sensitive, precise and reliable. Finally, the use of the TDA-AAS can be considered instead of the ICP-MS in hair analysis in order to reduce sample manipulation with minor risk of contamination, less time consuming due to the absence of the digestion step and cheaper analyses.

  18. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of arsenic and selenium in water and sediment by graphite furnace atomic absorption spectrometry

    USGS Publications Warehouse

    Jones, Sandra R.; Garbarino, John R.

    1999-01-01

    Graphite furnace-atomic absorption spectrometry (GF-AAS) is a sensitive, precise, and accurate technique that can be used to determine arsenic and selenium in samples of water and sediment. The GF-AAS method has been developed to replace the hydride generation-atomic absorption spectrometry (HG-AAS) methods because the method detection limits are similar, bias and variability are comparable, and interferences are minimal. Advantages of the GF-AAS method include shorter sample preparation time, increased sample throughput from simultaneous multielement analysis, reduced amount of chemical waste, reduced sample volume requirements, increased linear concentration range, and the use of a more accurate digestion procedure. The linear concentration range for arsenic and selenium is 1 to 50 micrograms per liter in solution; the current method detection limit for arsenic in solution is 0.9 microgram per liter; the method detection limit for selenium in solution is 1 microgram per liter. This report describes results that were obtained using stop-flow and low-flow conditions during atomization. The bias and variability of the simultaneous determination of arsenic and selenium by GF-AAS under both conditions are supported with results from standard reference materials--water and sediment, real water samples, and spike recovery measurements. Arsenic and selenium results for all Standard Reference Water Samples analyzed were within one standard deviation of the most probable values. Long-term spike recoveries at 6.25, 25.0, 37.5 micrograms per liter in reagent-, ground-, and surface-water samples for arsenic averaged 103 plus or minus 2 percent using low-flow conditions and 104 plus or minus 4 percent using stop-flow conditions. Corresponding recoveries for selenium were 98 plus or minus 13 percent using low-flow conditions and 87 plus or minus 24 percent using stop-flow conditions. Spike recoveries at 25 micrograms per liter in 120 water samples ranged from 97 to 99 percent

  19. The role of atomic absorption spectrometry in geochemical exploration

    USGS Publications Warehouse

    Viets, J.G.; O'Leary, R. M.

    1992-01-01

    In this paper we briefly describe the principles of atomic absorption spectrometry (AAS) and the basic hardware components necessary to make measurements of analyte concentrations. Then we discuss a variety of methods that have been developed for the introduction of analyte atoms into the light path of the spectrophotometer. This section deals with sample digestion, elimination of interferences, and optimum production of ground-state atoms, all critical considerations when choosing an AAS method. Other critical considerations are cost, speed, simplicity, precision, and applicability of the method to the wide range of materials sampled in geochemical exploration. We cannot attempt to review all of the AAS methods developed for geological materials but instead will restrict our discussion to some of those appropriate for geochemical exploration. Our background and familiarity are reflected in the methods we discuss, and we have no doubt overlooked many good methods. Our discussion should therefore be considered a starting point in finding the right method for the problem, rather than the end of the search. Finally, we discuss the future of AAS relative to other instrumental techniques and the promising new directions for AAS in geochemical exploration. ?? 1992.

  20. DETERMINATION OF TOTAL MERCURY IN FISH TISSUES USING PYROLYSIS ATOMIC ABSORPTION SPECTROMETRY WITH GOLD AMALGAMATION

    EPA Science Inventory

    A simple and rapid procedure for measuring total mercury in fish tissues is evaluated and
    compared with conventional techniques. Using an automated instrument incorporating combustion, preconcentration by amalgamation with gold, and atomic absorption spectrometry (AAS), mill...

  1. EPA Method 245.1: Determination of Mercury in Water by Cold Vapor Atomic Absorption Spectrometry

    EPA Pesticide Factsheets

    SAM lists this method for preparation and analysis of aqueous liquid and drinking water samples. This method will determine mercuric chloride and methoxyethylmercuric acetate as total mercury using cold vapor atomic absorption spectrometry.

  2. Microdroplet Sample Application in Electrothermal Atomization for Atomic Absorption Spectrometry.

    DTIC Science & Technology

    1982-03-29

    ad ideftify by Week amber) atomic absorption spectroscopy microsampl ing graphite- furnace AAS automation C> 20. AOSTRACT (Coninuhe an reveresi de It...furnace and spectrometer system as well as for partial support of this project. REFERENCES 1. J. D. Winefordner, Atomic Absorption Spectroscopy , G. F

  3. Differentiation and classification of beers with flame atomic spectrometry and molecular absorption spectrometry and sample preparation assisted by microwaves

    NASA Astrophysics Data System (ADS)

    Bellido-Milla, Dolores; Moreno-Perez, Juana M.; Hernández-Artiga, María. P.

    2000-07-01

    The characterization of beer samples has a lot of interest because their composition can affect the taste and stability of beer and consumer health. Flame atomic absorption spectrometry was used to determine Fe, Mn, Zn, Cu, Mg, Ca and Al. Sodium and K were determined by flame atomic emission spectrometry. A sample preparation method was developed, based on treatment with HNO 3 and H 2O 2 in a microwave oven. This has many advantages over the methods found in the literature. The combination of the results of atomic spectrometry and the spectrum obtained by molecular absorption spectrometry provides information on the inorganic and organic components of the samples. The application of chemometric techniques to chemical composition data could be extremely useful for food quality control. The metal concentrations, the molecular absorption spectrum, the pH and conductivity of each sample were subject to analysis of variance and linear discriminant analysis. Twenty-five different beer samples were used to differentiate and classify different types of beers.

  4. Study of the analytical methods for iron determination in complex organic liquids by atomic absorption spectrometry

    SciTech Connect

    Torre, M.; Gonzalez, M.C.; Jimenez, O.; Rodriquez, A.R. )

    1990-01-01

    In the determination of iron in complex organic liquids by atomic absorption spectrometry (A.A.S.), methods of sample preparation, such as dilution with an organic solvent and sample pretreatment to destroy organic material, are investigated. Moreover, methods of analysis using calibration curve and standard additions are presented. The possible cause of error associated with iron determination in organic samples by flame (F-A.A.S.) and graphite furnace (GF-A.A.S.) atomic absorption spectrometry are discussed. From all of these studies, the use of graphite furnace atomic absorption spectrometry after sample dilution with methyl isobutyl ketone, and the use of the method of standard additions are advised for iron determination.

  5. Piezoelectric-tuned microwave cavity for absorption spectrometry

    DOEpatents

    Leskovar, Branko; Buscher, Harold T.; Kolbe, William F.

    1978-01-01

    Gas samples are analyzed for pollutants in a microwave cavity that is provided with two highly polished walls. One wall of the cavity is mechanically driven with a piezoelectric transducer at a low frequency to tune the cavity over a band of microwave frequencies in synchronism with frequency modulated microwave energy applied to the cavity. Absorption of microwave energy over the tuned frequencies is detected, and energy absorption at a particular microwave frequency is an indication of a particular pollutant in the gas sample.

  6. Cinchocaine hydrochloride determination by atomic absorption spectrometry and spectrophotometry.

    PubMed

    Abdel-Ghani, Nour T; Youssef, Ahmed F A; Awady, Mohamed A

    2005-05-01

    Two sensitive spectrophotometric and atomic absorption spectrometric procedures have been developed for determination of cinchocaine hydrochloride (Cin.Cl) in pure form and in pharmaceutical formulation. The spectrophotometric method was based on formation of an insoluble colored ion-associate between the cited drug and tetrathiocyanatocobaltate (CoTC) or hexathiocyanatochromate (CrTC) which dissolved and extracted in an organic solvent. The optimal experimental conditions for quantitative extraction such as pH, concentration of the reagents and solvent were studied. Toluene and iso-butyl alcohol proved to be the most suitable solvents for quantitative extraction of Cin-CoTC and Cin-CrTC ion-associates with maximum absorbance at 620 and 555 nm, respectively. The optimum concentration ranges, molar absorptivities, Ringbom ranges and Sandell sensitivities were also evaluated. The atomic absorption spectrometric method is based on measuring of the excess cobalt or chromium in the aqueous solution, after precipitation of the drug, at 240.7 and 357.9 nm, respectively. Linear application ranges, characteristic masses and detection limits were 57.99-361.9, 50.40 and 4.22 microg ml(-1) of Cin.Cl, in case of CoTC, while 37.99-379.9, 18.94 and 0.81 microg ml(-1) in case of CrTC.

  7. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of whole-water recoverable arsenic, boron, and vanadium using inductively coupled plasma-mass spectrometry

    USGS Publications Warehouse

    Garbarino, John R.

    2000-01-01

    Analysis of in-bottle digestate by using the inductively coupled plasma?mass spectrometric (ICP?MS) method has been expanded to include arsenic, boron, and vanadium. Whole-water samples are digested by using either the hydrochloric acid in-bottle digestion procedure or the nitric acid in-bottle digestion procedure. When the hydrochloric acid in-bottle digestion procedure is used, chloride must be removed from the digestate by subboiling evaporation before arsenic and vanadium can be accurately determined. Method detection limits for these elements are now 10 to 100 times lower than U.S. Geological Survey (USGS) methods using hydride generation? atomic absorption spectrophotometry (HG? AAS) and inductively coupled plasma? atomic emission spectrometry (ICP?AES), thus providing lower variability at ambient concentrations. The bias and variability of the methods were determined by using results from spike recoveries, standard reference materials, and validation samples. Spike recoveries in reagent-water, surface-water, ground-water, and whole-water recoverable matrices averaged 90 percent for seven replicates; spike recoveries were biased from 25 to 35 percent low for the ground-water matrix because of the abnormally high iron concentration. Results for reference material were within one standard deviation of the most probable value. There was no significant difference between the results from ICP?MS and HG?AAS or ICP?AES methods for the natural whole-water samples that were analyzed.

  8. Determination of arsenic and selenium in environmental and agricultural samples by hydride generation atomic absorption spectrometry

    SciTech Connect

    Hershey, J.W.; Oostdyk, T.S.; Keliher, P.N.

    1988-11-01

    Agricultural and environmental samples are digested with acid, and arsenic and selenium are determined using hydride generation atomic absorption spectrometry. Interelement interferences are eliminated by high acid concentrations or cation-exchange resins. Agreement with standard reference material is excellent. The technique is also applied to actual samples.

  9. Near edge X-ray absorption mass spectrometry on coronene

    SciTech Connect

    Reitsma, G.; Deuzeman, M. J.; Hoekstra, R.; Schlathölter, T.; Boschman, L.; Hoekstra, S.

    2015-01-14

    We have investigated the photoionization and photodissociation of free coronene cations C{sub 24}H{sub 12}{sup +} upon soft X-ray photoabsorption in the carbon K-edge region by means of a time-of-flight mass spectrometry approach. Core excitation into an unoccupied molecular orbital (below threshold) and core ionization into the continuum both leave a C 1s vacancy, that is subsequently filled in an Auger-type process. The resulting coronene dications and trications are internally excited and cool down predominantly by means of hydrogen emission. Density functional theory was employed to determine the dissociation energies for subsequent neutral hydrogen loss. A statistical cascade model incorporating these dissociation energies agrees well with the experimentally observed dehydrogenation. For double ionization, i.e., formation of intermediate C{sub 24}H{sub 12}{sup 3+⋆}trications, the experimental data hint at loss of H{sup +} ions. This asymmetric fission channel is associated with hot intermediates, whereas colder intermediates predominantly decay via neutral H loss.

  10. Metal content monitoring in Hypericum perforatum pharmaceutical derivatives by atomic absorption and emission spectrometry.

    PubMed

    Gomez, María R; Soledad, Cerutti; Olsina, Roberto A; Silva, María F; Martínez, Luis D

    2004-02-18

    Metals have been investigated in different plant materials in order to establish their normal concentration range and consider their role in plants as part of human medicinal treatment. Metal monitoring as a pattern recognition method is a promising tool in the characterization and/or standardization of phytomedicines. In the present work measurable amounts of Ca, Cu, K, Li, Mg, Mn, Na, Ni, and Zn were detected in phytopharmaceutical derivatives of Hypericum perforatum by atomic techniques. Atomic methodologies like flame atomic absorption spectrometry (FAAS) and electrothermal atomic absorption spectrometry (ETAAS) allow reliable determination of mineral content in pharmaceutical quality control of medicinal plants. Additionally, capillary electrophoresis (CE) patterns of characteristic components (fingerprints) have been performed for the search of adulterants in phytopharmaceutical products.

  11. Literature study of microwave-assisted digestion using electrothermal atomic absorption spectrometry.

    PubMed

    Chakraborty, R; Das, A K; Cervera, M L; De La Guardia, M

    1996-05-01

    The literature on the use of microwave-assisted digestion procedures for subsequent sample analysis by means of electrothermal atomic absorption spectrometry (ETAAS) is reviewed. The literature survey reveals that this digestion technique has been applied mainly for biological materials. The elements most extensively determined by this method are cadmium and lead followed by copper, chromium, nickel and iron. The microwave digestion conditions, ETAAS furnace programmes and analytical details of the developed methodologies have been carefully revised.

  12. Automation of preparation of nonmetallic samples for analysis by atomic absorption and inductively coupled plasma spectrometry

    NASA Technical Reports Server (NTRS)

    Wittmann, A.; Willay, G.

    1986-01-01

    For a rapid preparation of solutions intended for analysis by inductively coupled plasma emission spectrometry or atomic absorption spectrometry, an automatic device called Plasmasol was developed. This apparatus used the property of nonwettability of glassy C to fuse the sample in an appropriate flux. The sample-flux mixture is placed in a composite crucible, then heated at high temperature, swirled until full dissolution is achieved, and then poured into a water-filled beaker. After acid addition, dissolution of the melt, and filling to the mark, the solution is ready for analysis. The analytical results obtained, either for oxide samples or for prereduced iron ores show that the solutions prepared with this device are undistinguished from those obtained by manual dissolutions done by acid digestion or by high temperature fusion. Preparation reproducibility and analytical tests illustrate the performance of Plasmasol.

  13. Determination of nanogram amounts of bismuth in rocks by atomic absorption spectrometry with electrothermal atomization

    USGS Publications Warehouse

    Kane, J.S.

    1979-01-01

    Bismuth concentrations as low as 10 ng g-1 in 100-mg samples of geological materials can be determined by atomic absorption spectrometry with electrothermal atomization. After HF-HClO4 decomposition of the sample, bismuth is extracted as the iodide into methyl isobutyl ketone and is then stripped with ethylenediaminetetraacetic acid into the aqueous phase. Aliquots of this solution are pipetted into the graphite furnace and dried, charred, and atomized in an automated sequence. Atomic absorbance at the Bi 223.1-nm line provides a measure of the amount of bismuth present. Results are presented for 14 U.S. Geological Survey standard rocks. ?? 1979.

  14. [Determination of calcium and magnesium in wheat flour by suspension sampling-flame atomic absorption spectrometry].

    PubMed

    Liu, L; Zhang, Q; Hu, Y

    1999-06-01

    Suspension sampling technique was applied to flame atomic absorption spectrometry and was successfully used to determine calcium and magnesium in wheat flour. The wheat flour was suspended in agar sol containing dibutyl phthalate and made into suspension. Choice of suspension agent and elimination of chemical interference were studied. The test solution was injected into air-acetylene flame to determine calcium and magnesium by standard addition method. Determination results were consistent with those obtained by ashing method. The t-test showed that no difference was found between the two methods. Displacement of ashing method by suspension sampling method for the sample pretreatment is possible. This method is convenient, rapid and accurate.

  15. Determination of mercury in sewage sludge by direct slurry sampling graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Baralkiewicz, Danuta; Gramowska, Hanka; Kózka, Małgorzata; Kanecka, Anetta

    2005-03-01

    Ultrasonic slurry sampling electrothermal atomic absorption spectrometry (ETAAS) method was elaborated to the determination of Hg in sewage sludge samples with the use of KMnO 4+Pd modifier. The minimum sample amount required for slurry preparation with respect to sample homogeneity was evaluated by weighting masses between 3 and 30 mg directly into the autosampler cups. Validation of the proposed method was performed with the use of Certified Reference Materials of sewage sludge, CRM 007-040 and CRM 144R. Two sewage sludge samples from Poznañ (Poland) city were analysed using the present direct method and a method with sample digestion, resulting in no difference within statistical error.

  16. Determination of tetraalkyllead compounds in gasoline by liquid chromatography-atomic absorption spectrometry

    USGS Publications Warehouse

    Messman, J.D.; Rains, T.C.

    1981-01-01

    A liquid chromatography-atomic absorption spectrometry (LC-AAS) hybrid analytical technique is presented for metal speciation measurements on complex liquid samples. The versatility and inherent metal selectivity of the technique are Illustrated by the rapid determination of five tetraalkyllead compounds in commercial gasoline. Separation of the individual tetraalkyllead species is achieved by reversed-phase liquid chromatography using an acetonitrile/water mobile phase. The effluent from the liquid Chromatograph Is introduced directly into the aspiration uptake capillary of the nebulizer of an air/acetylene flame atomic absorption spectrometer. Spectral interferences due to coeluting hydrocarbon matrix constituents were not observed at the 283.3-nm resonance line of lead used for analysis. Detection limits of this LC-AAS hydrid analytical technique, based on a 20-??L injection, are approximately 10 ng Pb for each tetraalkyllead compound.

  17. Solid sampling determination of magnesium in lithium niobate crystals by graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Dravecz, Gabriella; Laczai, Nikoletta; Hajdara, Ivett; Bencs, László

    2016-12-01

    The vaporization/atomization processes of Mg in high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS-GFAAS) were investigated by evaporating solid (powder) samples of lithium niobate (LiNbO3) optical single crystals doped with various amounts of Mg in a transversally heated graphite atomizer (THGA). Optimal analytical conditions were attained by using the Mg I 215.4353 nm secondary spectral line. An optimal pyrolysis temperature of 1500 °C was found for Mg, while the compromise atomization temperature in THGAs (2400 °C) was applied for analyte vaporization. The calibration was performed against solid (powered) lithium niobate crystal standards. The standards were prepared with exactly known Mg content via solid state fusion of the oxide components of the matrix and analyte. The correlation coefficient (R value) of the linear calibration was not worse than 0.9992. The calibration curves were linear in the dopant concentration range of interest (0.74-7.25 mg/g Mg), when dosing 3-10 mg of the powder samples into the graphite sample insertion boats. The Mg content of the studied 19 samples was in the range of 1.69-4.13 mg/g. The precision of the method was better than 6.3%. The accuracy of the results was verified by means of flame atomic absorption spectrometry with solution sample introduction after digestion of several crystal samples.

  18. [The application of atomic absorption spectrometry in automatic transmission fault detection].

    PubMed

    Chen, Li-dan; Chen, Kai-kao

    2012-01-01

    The authors studied the innovative applications of atomic absorption spectrometry in the automatic transmission fault detection. After the authors have determined Fe, Cu and Cr contents in the five groups of Audi A6 main metal in automatic transmission fluid whose travel course is respectively 10-15 thousand kilometers, 20-26 thousand kilometers, 32-38 thousand kilometers, 43-49 thousand kilometers, and 52-58 thousand kilometers by atomic absorption spectrometry, the authors founded the database of primary metal content in the Audi A6 different mileage automatic transmission fluid (ATF). The research discovered that the main metal content in the automatic transmission fluid increased with the vehicles mileage and its normal metal content level in the automatic transmission fluid is between the two trend lines. The authors determined the main metal content of automatic transmission fluid which had faulty symptoms and compared it with its database value. Those can not only judge the wear condition of the automatic transmission which had faulty symptoms but also help the automobile detection and maintenance personnel to diagnose automatic transmission failure reasons without disintegration. This reduced automobile maintenance costs, and improved the quality of automobile maintenance.

  19. Investigation of chemical modifiers for phosphorus in a graphite furnace using high-resolution continuum source atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Lepri, Fábio G.; Dessuy, Morgana B.; Vale, Maria Goreti R.; Borges, Daniel L. G.; Welz, Bernhard; Heitmann, Uwe

    2006-08-01

    Phosphorus is not one of the elements that are typically determined by atomic absorption spectrometry, but this technique nevertheless offers several advantages that make it attractive, such as the relatively great freedom from interferences. As the main resonance lines for phosphorus are in the vacuum-ultraviolet, inaccessible by conventional atomic absorption spectrometry equipment, Ĺvov and Khartsyzov proposed to use the non-resonance doublet at 213.5 / 213.6 nm. Later it turned out that with conventional equipment it is necessary to use a chemical modifier in order to get reasonable sensitivity, and lanthanum was the first one suggested for that purpose. In the following years more than 30 modifiers have been proposed for the determination of this element, and there is no consensus about the best one. In this work high-resolution continuum source atomic absorption spectrometry has been used to investigate the determination of phosphorus without a modifier and with the addition of selected modifiers of very different nature, including the originally recommended lanthanum modifier, several palladium-based modifiers and sodium fluoride. As high-resolution continuum source atomic absorption spectrometry is revealing the spectral environment of the analytical line at high resolution, it became obvious that without the addition of a modifier essentially no atomic phosphorus is formed, even at 2700 °C. The absorption measured with line source atomic absorption spectrometry in this case is due to the PO molecule, the spectrum of which is overlapping with the atomic line. Palladium, with or without the addition of calcium or ascorbic acid, was found to be the only modifier to produce almost exclusively atomic phosphorus. Lanthanum and particularly sodium fluoride produced a mixture of P and PO, depending on the atomization temperature. This fact can explain at least some of the discrepancies found in the literature and some of the phenomena observed in the

  20. The environmental effects of trace elements concentration in sea snails using atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    El-Amri, F. A.

    2003-05-01

    Water pollution bas increased in heavy industrialised areas. Most industrial water wastes end up in the sea. Monitoring the elemental composition in marine organisms, such as snails, provides the essential elements in living organisms and through the food chain to man. 50 samples of each of two kinds of snails have been collected from the west coast of Libya. Samples were digeste with nitric acid and the concentration of Copper, Iron, Magnesium and Zinc were determined by atomic absorption spectrometry. The results shows that Mg has the highest value while the Copper has the lowest in both kind of snaiis. A pattern of the trace elements concentration was investigated regarding the size and kind of snails.

  1. The direct determination of HgS by thermal desorption coupled with atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Coufalík, Pavel; Zvěřina, Ondřej; Komárek, Josef

    2016-04-01

    This research was aimed at the direct determination of HgS in environmental samples by means of thermal desorption coupled with atomic absorption spectrometry. Operating parameters of the apparatus used for thermal desorption (including a prototype desorption unit) are described in this work, as well as the procedure for measuring mercury release curves together with an evaluation of the analytical signal including two methods of peak integration. The results of thermal desorption were compared with HgS contents obtained by sequential extraction. The limits of quantification of the proposed method for the selective determination of the black and red forms of HgS were 4 μg kg- 1 and 5 μg kg- 1, respectively. The limit of quantification of red HgS in soils was 35 μg kg- 1. The developed analytical procedure was applied to soil and sediment samples from historical mining areas.

  2. Determination of some heavy metals by flame atomic absorption spectrometry before coprecipitation with neodymium hydroxide.

    PubMed

    Soylak, Mustafa; Kizil, Nebiye

    2011-01-01

    A procedure is described for the determination of trace amounts of Cd(II), Ni(II), Cu(II), Pb(II), Fe(III), Co(II), and Mn(II) that combines flame atomic absorption spectrometry with neodymium hydroxide coprecipitation. The influences of analytical parameters (amount of neodymium, pH of the model solutions, etc.) that affect quantitative recoveries of the analyte ions were investigated. The effects of concomitant ions were also examined. The detection limits for analytes were found in the range of 0.2-3.3 microg/L. The validation of the presented procedure was controlled by analysis of certified reference materials (National Institute of Standards and Technology 1570a spinach leaves and TMDA 54.4 fortified lake water). The applications of the procedure were performed by the analysis of water, food, and herbal plants from Turkey.

  3. Determination of selenium in urine by hydride generation atomic absorption spectrometry.

    PubMed

    Navarro, M; Lopez, H; Lopez, M C; Perez, V

    1996-01-01

    A procedure has been developed for determination of total selenium in urine by hydride generation atomic absorption spectrometry. Mineralization was performed with a nitric acid-perchloric acid mixture on a thermostated digestion block. The method was validated by comparison with the method involving mineralization in a microwave acid digestion bomb containing nitric acid and small amounts of vanadium pentoxide. Se(VI) was reduced to Se(IV) by dissolution in 7N HCl. Sample recoveries, precision studies, and analyses of a certified reference material demonstrated the reliability and accuracy of this technique. Urine samples had selenium concentrations ranging from 4.6 to 50.3 micrograms/L. These values correspond to an average of 54.9 micrograms per person per day total ingested and bioavailable Se in the daily diet.

  4. Liquid-phase microextraction combined with graphite furnace atomic absorption spectrometry: A review.

    PubMed

    de la Calle, Inmaculada; Pena-Pereira, Francisco; Lavilla, Isela; Bendicho, Carlos

    2016-09-14

    An overview of the combination of liquid-phase microextraction (LPME) techniques with graphite furnace atomic absorption spectrometry (GFAAS) is reported herein. The high sensitivity of GFAAS is significantly enhanced by its association with a variety of miniaturized solvent extraction approaches. LPME-GFAAS thus represents a powerful combination for determination of metals, metalloids and organometallic compounds at (ultra)trace level. Different LPME modes used with GFAAS are briefly described, and the experimental parameters that show an impact in those microextraction processes are discussed. Special attention is paid to those parameters affecting GFAAS analysis. Main issues found when coupling LPME and GFAAS, as well as those strategies reported in the literature to solve them, are summarized. Relevant applications published on the topic so far are included.

  5. [Determination of Cu, Zn and Fe in Huaiyao by suspension sampling-flame atomic absorption spectrometry].

    PubMed

    Wei, Wei; Qu, Ling-bo; Li, Jian-jun; Li, Yan-hong

    2002-10-01

    A new method--suspension sampling technique was applied to flame atomic absorption spectrometry and was successfully used to determine Cu, Zn, Fe in Huaiyao. Then studied the choice of suspension agent and elimination of chemical interference. The huaiyao sample was suspended in agar sol, and injected into air-acetylene flame by using standard addition method to determine Cu, Zn, Fe. Determined results were consistent with those obtained by HNO3 + H2SO4 + HClO4 method. The t-test showed that no obvious difference was found between the two methods. Displacement of HNO3 + H2SO4 + HClO4 method by suspension sampling method for the sample pretreatment is possible. This method is convenient, rapid and accurate.

  6. [Determination of inorganic elements in different parts of Sonchus oleraceus L by flame atomic absorption spectrometry].

    PubMed

    Wang, Nai-Xing; Cui, Xue-Gui; Du, Ai-Qin; Mao, Hong-Zhi

    2007-06-01

    Flame atomic absorption spectrometry with air-acetylene flame was used for the determination of inorganic metal elements in different parts ( flower, leaf, stem and root) of Sonchus oleraceus L. The contents of Ca, Mg, K, Na, Fe, Mn, Cu, Zn, Cr, Co, Ni, Pb and Cd in the flower, leaf, stem and root of Sonchus oleraceus L were compared. The order from high to low of the additive weight (microg x g(-1)) for the 13 kinds of metal elements is as follows: leaf (77 213.72) > flower (47 927.15) > stem(42 280.99) > root (28 131.18). From the experimental results it was found that there were considerable differences in the contents of the metal elements in different parts, and there were richer contents of Fe, Zn, Mn and Cu in root and flower, which are necessary to human health, than in other parts.

  7. Determination of arsenic in vegetable samples by hydride generation atomic absorption spectrometry

    SciTech Connect

    Navarro, M.; Lopez, M.C.; Lopez, H.; Sanchez, M.

    1992-11-01

    A procedure is described for the determination of arsenic in vegetable samples by hydride generation atomic absorption spectrometry. The samples are mineralized in a microwave acid digestion bomb with nitric acid in the presence of small amounts of vanadium pentoxide. The determination of arsenic is made by the standard addition method. A certified reference sample is analyzed, and the result obtained agreed well with the certified value. The detection limit (dry weight) was about 0.020 {mu}g/g. Reproducibility relative standard deviations ranged from 6.45% at 0.152 {mu}g As/g to 8.31% at 0.059 {mu}g As/g. The concentrations of arsenic in vegetable samples ranged from 0.029 to 0.444 {mu}g/g (fresh weight). 24 refs., 4 tabs.

  8. Slurry sampling electrothermal atomic absorption spectrometry as screening method for chromium in compost.

    PubMed

    Laborda, F; Górriz, M P; Castillo, J R

    2004-10-20

    Ultrasonic slurry sample introduction was applied to the determination of total chromium in composted materials by electrothermal atomic absorption spectrometry (ETAAS). The effect of grinding on the heterogeneity of the test samples and on the attainable precision was studied. The repeatability was influenced by the heterogeneity of the test samples at the mug-level, the R.S.D. of the measurements being 15%. The reproducibility depended on the heterogeneity of the test sample at the mg level, and it could be improved from 11 to 7% by increasing the grinding time. The characteristic mass was 2.6pg and the detection limit for the optimised procedure at the 0.04% (w/v) slurry concentration, 370ngg(-1). Good agreement with a certified reference material and with the conventional microwave assisted digestion method was found by using external calibration with aqueous standards. The performance of the method for screening purposes was evaluated.

  9. Determination of lead in fish samples by slurry sampling electrothermal atomic absorption spectrometry.

    PubMed

    Huang, S J; Jiang, S J

    2000-08-01

    Ultrasonic slurry sampling electrothermal atomic absorption spectrometry (USS-ETAAS) was been applied to the determination of lead in several fish samples. The influences of instrument operating conditions and slurry preparation on the signal were examined. Palladium and ammonium nitrate were used as the modifier to improve the signal. Since the sensitivity to lead in various fish slurries and aqueous solutions was different, the standard additions method was used for the determination of lead in these fish samples. The method was applied to the determination of lead in dogfish muscle reference material (DORM-2) and a swordfish muscle sample purchased from the local market. The analysis results agreed with the reference value. The accuracy was better than 6%. The precision between sample replicates was better than 16% with the USS-ETAAS method. The detection limit of lead estimated from standard additions curve was about 0.053-0.058 microgram g-1 in different samples.

  10. High purity polyimide analysis by solid sampling graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Santos, Rafael F.; Carvalho, Gabriel S.; Duarte, Fabio A.; Bolzan, Rodrigo C.; Flores, Erico M. M.

    2017-03-01

    In this work, Cr, Cu, Mn, Na and Ni were determined in high purity polyimides (99.5%) by solid sampling graphite furnace atomic absorption spectrometry (SS-GFAAS) using Zeeman effect background correction system with variable magnetic field, making possible the simultaneous measurement at high or low sensitivity. The following analytical parameters were evaluated: pyrolysis and atomization temperatures, feasibility of calibration with aqueous solution, linear calibration range, sample mass range and the use of chemical modifier. Calibration with aqueous standard solutions was feasible for all analytes. No under or overestimated results were observed and up to 10 mg sample could be introduced on the platform for the determination of Cr, Cu, Mn, Na and Ni. The relative standard deviation ranged from 3 to 20%. The limits of detection (LODs) achieved using the high sensitivity mode were as low as 7.0, 2.5, 1.7, 17 and 0.12 ng g- 1 for Cr, Cu, Mn, Na and Ni, respectively. No addition of chemical modifier was necessary, except for Mn determination where Pd was required. The accuracy was evaluated by analyte spike and by comparison of the results with those obtained by inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry after microwave-assisted digestion in a single reaction chamber system and also by neutron activation analysis. No difference among the results obtained by SS-GFAAS and those obtained by alternative analytical methods using independent techniques. SS-GFAAS method showed some advantages, such as the determination of metallic contaminants in high purity polyimides with practically no sample preparation, very low LODs, calibration with aqueous standards and determination in a wide range of concentration.

  11. Quantitative analysis for a color-change of humidity indicator by microscopic absorption spectrometry.

    PubMed

    Matsumoto, Tomoko; Mitsumura, Yoko; Miyamoto, Miyuki; Matsumoto, Jin; Shiragami, Tsutomu; Fueda, Yoshiyuki; Nobuhara, Kazunori; Yasuda, Masahide

    2011-01-01

    A sensitive and easily distinguishable cobalt-free humidity indicator of porphyrin-silica gel-MgCl(2) composite was prepared from pH-induced spectra changeable tetraarylporphyrin, silica gel (SiO(2)), and MgCl(2). The pH change arose from proton release under dry conditions, and proton capture under humid conditions by a reversible reaction between MgCl(2) and a silanol group of SiO(2). A pink-orange porphyrin-Si(OH)(2)-MgCl(2) composite was dried to give a green protonated porphyrin-SiO(2)Mg composite. The optimized concentrations of MgCl(2) to make the concentrations of protonated porphyrin maximum under dry conditions were determined by absorption spectrometry of the green composite using a confocal laser scanning microscope as a microscopic spectrometer. Moreover, the green composite was prepared by heating dichloro(tetraarylporphyrinato)phosphorus chloride with MgCl(2) and SiO(2). The humidity-sensitivity of the green composite was evaluated by the absorption spectra under controlled humidity. A distinguishable color change of the green composite took place below 30% of relative humidity.

  12. Solution and slurry sampling electrothermal atomic absorption spectrometry for the analysis of high purity quartz

    NASA Astrophysics Data System (ADS)

    Hauptkorn, Susanne; Krivan, Viliam

    1996-07-01

    A slurry sampling electrothermal atomic absorption spectrometry (ETAAS) method for the determination of Al, Cr, Cu, Fe, K, Li, Mg, Mn and Na at trace and ultratrace level in high purity quartz samples has been developed. The influence of atomization temperature, internal gas flow during atomization and carbide modification of the graphite tube on the background absorption has been studied. Simple quantification via calibration curves, recorded with aqueous standards, is possible for all elements except Al. The performance and the accuracy of the slurry sampling technique are compared to those of the analysis of hydrofluoric acid digests. With both methods, the blanks could be substantially reduced by minimization of sample handling. Because of essentially higher applicable sample portions, the solution technique provides lower limits of detection for all elements excluding Al, Na and K. For the slurry sampling technique, the achievable limits of detection are in the range of 2 (Mg) to 500 (Fe) ng g -1 and for the solution technique, they are between 0.4 (Mg) and 500 (Al) ng g -1. Thus, both developed methods are well suited for ultratrace analysis of high purity quartz for microelectronic applications. The results obtained by these two ETAAS techniques are compared with those of independent methods including neutron activation analysis.

  13. Determination of sulfur in food by high resolution continuum source flame molecular absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Zambrzycka, Elżbieta; Godlewska-Żyłkiewicz, Beata

    2014-11-01

    In the present work, a fast, simple and sensitive analytical method for determination of sulfur in food and beverages by high resolution continuum source flame molecular absorption spectrometry was developed. The determination was performed via molecular absorption of carbon monosulfide, CS. Different CS rotational lines (257.959 nm, 258.033 nm, 258.055 nm), number of pixels and types of standard solution of sulfur, namely: sulfuric acid, sodium sulfate, ammonium sulfate, sodium sulfite, sodium sulfide, DL-cysteine, and L-cystine, were studied in terms of sensitivity, repeatability of results as well as limit of detection and limit of quantification. The best results were obtained for measurements of absorption of the CS molecule at 258.055 nm at the wavelength range covering 3 pixels and DL-cysteine in 0.2 mol L- 1 HNO3 solution as a calibration standard. Under optimized conditions the limit of detection and the limit of quantification achieved for sulfur were 10.9 mg L- 1 and 36.4 mg L- 1, respectively. The repeatability of the results expressed as relative standard deviation was typically < 5%. The accuracy of the method was tested by analysis of digested biological certified reference materials (soya bean flour, corn flour and herbs) and recovery experiment for beverage samples with added known amount of sulfur standard. The recovery of analyte from such samples was in the range of 93-105% with the repeatability in the range of 4.1-5.0%. The developed method was applied for the determination of sulfur in milk (194 ± 10 mg kg- 1), egg white (2188 ± 29 mg kg- 1), mineral water (31.0 ± 0.9 mg L- 1), white wine (260 ± 4 mg L- 1) and red wine (82 ± 2 mg L- 1), as well as in sample rich in ions, such as bitter mineral water (6900 ± 100 mg L- 1).

  14. Application of thermospray flame furnace atomic absorption spectrometry for investigation of silver nanoparticles.

    PubMed

    Sirirat, Natnicha; Tetbuntad, Kornrawee; Siripinyanond, Atitaya

    2017-03-01

    Thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was applied to investigate the time-dependent absorption peak profile of various forms of silver. The thermospray flame furnace was set up with a 10-cm-long nickel tube with six holes, each 2.0 mm in diameter, to allow the flame to enter, and this nickel tube acted as a furnace. A sample of 300 μL was introduced into this furnace by use of water as a carrier at a flow rate of 0.5 mL min(-1) through the ceramic capillary (0.5-mm inner diameter and 2.0-mm outer diameter), which was inserted into the front hole of the nickel tube. The system was applied to examine atomization behaviors of silver nanoparticles (AgNPs) with particle sizes ranging from 10 to 100 nm. The atomization rate of AgNPs was faster than that of the dissolved silver ion. With increased amount of silver, the decay time observed from the time-dependent absorption peak profile was shortened in the case of dissolved silver ion, but it was increased in the case of AgNPs. With the particle size ranging from 10 to 100 nm, the detection sensitivity was indirectly proportional to the particle size, suggesting that TS-FF-AAS may offer insights into the particle size of AgNPs provided that the concentration of the silver is known. To obtain quantitative information on AgNPs, acid dissolution of the particles was performed before TS-FF-AAS analysis, and recoveries of 80-110% were obtained.

  15. Determination of Hg, Cd, Mn, Pb and Sn in seafood by solid sampling Zeeman atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Detcheva, A.; Grobecker, K. H.

    2006-04-01

    Direct solid sampling Zeeman atomic absorption spectrometric methods were developed and applied to the determination of mercury, cadmium, manganese, lead and tin in seafood. All elements but mercury were measured by a third generation Zeeman atomic absorption spectrometry combined with an automatic solid sampler. In 3-field- and dynamic mode the calibrations concentration range was substantially extended and high amounts of analyte were detectable without laborious dilution of solid samples. The measurements were based on calibrations using certified reference materials of organic matrices. In case solid certified reference materials were not available calibration by aqueous standard solutions was proved to be an alternative. No matrix effects were observed under the optimized conditions. Results obtained were in good agreement with the certified values. Solid sampling Zeeman atomic absorption spectrometry proved to be a reliable, rapid and low-cost method for the control of trace elements in seafood.

  16. Determination of mercury in phosphate fertilizers by cold vapor atomic absorption spectrometry.

    PubMed

    de Jesus, Robson M; Silva, Laiana O B; Castro, Jacira T; de Azevedo Neto, Andre D; de Jesus, Raildo M; Ferreira, Sergio L C

    2013-03-15

    In this paper, a method for the determination of mercury in phosphate fertilizers using slurry sampling and cold vapor atomic absorption spectrometry (CV QT AAS) is proposed. Because mercury (II) ions form strong complexes with phosphor compounds, the formation of metallic mercury vapor requires the presence of lanthanum chloride as a release agent. Thiourea increases the amount of mercury that is extracted from the solid sample to the liquid phase of the slurry. The method is established using two steps. First, the slurry is prepared using the sample, lanthanum chloride, hydrochloric acid solution and thiourea solution and is sonicated for 20 min. Afterward, mercury vapor is generated using an aliquot of the slurry in the presence of the hydrochloric acid solution and isoamylic alcohol with sodium tetrahydroborate solution as the reducing agent. The experimental conditions for slurry preparation were optimized using two-level full factorial design involving the factors: thiourea and lanthanum chloride concentrations and the duration of sonication. The method allows the determination of mercury by external calibration using aqueous standards with limits of detection and quantification of 2.4 and 8.2 μg kg(-1), respectively, and precision, expressed as relative standard deviation, of 6.36 and 5.81% for two phosphate fertilizer samples with mercury concentrations of 0.24 and 0.57 mg kg(-1), respectively. The accuracy was confirmed by the analysis of a certified reference material of phosphate fertilizer that was provided by the National Institute of Standards & Technology (NIST). The method was applied to determine mercury in six commercial samples of phosphate fertilizers. The mercury content varied from 33.97 to 209.28 μg kg(-1). These samples were also analyzed employing inductively coupled plasma mass spectrometry (ICP-MS). The ICP-MS results were consistent with the results from our proposed method.

  17. Atomic Absorption Spectrometry Analysis of Trace Elements in Degenerated Intervertebral Disc Tissue

    PubMed Central

    Kubaszewski, Łukasz; Zioła-Frankowska, Anetta; Frankowski, Marcin; Nowakowski, Andrzej; Czabak-Garbacz, Róża; Kaczmarczyk, Jacek; Gasik, Robert

    2014-01-01

    Background Few studies have investigated trace elements (TE) in human intervertebral disc (IVD) tissue. Trace element presence can have diverse meanings: essential TE show the metabolic modalities of the tissue, while environmentally-related TE indicate pollution and tissue-specific absorption and accumulation. IVD is a highly specific compartment with impaired communication with adjacent bone. Analysis of TE in IVD provides new insights regarding tissue metabolism and IVD communication with other tissues. Material/Methods Thirty intervertebral discs were acquired from 22 patients during surgical treatment for degenerative disease. Atomic absorption spectrometry was used to evaluate the concentrations of Al, Cd, Pb, Cu, Ni, Mo, Mg, and Zn. Results Al, Pb, Cu, Mg, and Zn were detected in all samples. Pb was significantly positively correlated with age, and Ni concentration was weakly correlated with population count in the patient’s place of residence. Only Cu was observed in higher concentrations in IVD compared to in other tissues. Significant positive correlations were observed between the following pairs: Mg/Zn, Mg/Al, Mg/Pb, Zn/Al, Zn/Pb, and Al/Pb. Negative correlations were observed between Mg/Cd, Zn/Cd, Mg/Mo, and Mo/Pb. Conclusions This study is one of few to profile the elements in intervertebral discs in patients with degenerative changes. We report significant differences between trace element concentrations in intervertebral discs compared to in other tissues. Knowledge of the TE accumulation pattern is vital for better understanding intervertebral disc nutrition and metabolism. PMID:25366266

  18. Low-resolution continuum source simultaneous multi-element electrothermal atomic absorption spectrometry: steps into practice

    NASA Astrophysics Data System (ADS)

    Katskov, Dmitri

    2015-03-01

    The theory and practical problems of continuum source simultaneous multi-element electrothermal atomic absorption spectrometry (SMET AAS) are discussed by the example of direct analysis of underground water. The experimental methodology is based on pulse vaporization of the sample in a fast heated graphite tube and measurement of transient absorption of continuum spectrum radiation from D2 and Xe lamps within 200-400 nm wavelengths range with a low resolution spectral instrument and linear charge-coupled device. The setup permits the acquisition of 200 spectra during 1 s atomization pulse. Respective data matrix absorbance vs wavelength/time is employed for the quantification of elements in the sample. The calculation algorithm developed includes broad band and continuum background correction, linearization of function absorbance vs. concentration of atomic vapor and integration of thus modified absorbance at the resonance lines of the elements to be determined. Practical application shows that the method can be employed for the direct simultaneous determination of about 20 elements above microgram per liter level within 3-5 orders of the magnitude concentration range. The investigated sources of measurement errors are mainly associated with the atomization and vapor transportation problems, which are aggravated for the simultaneous release of major and minor sample constituents. Respective corrections concerning the selection of analytical lines, optimal sampling volume, matrix modification and cleaning of the atomizer have been introduced in the SMET AAS analytical technology. Under the optimized experimental conditions the calibration curves in Log-Log coordinates for all the investigated analytes in the single or multi-element reference solutions are approximated by the first order equations. The use of these equations as permanent characteristics of the setup enables instant quantification of Al, Ca, Co, Cr, Cu, Fe, Mg, Mn and Ni in the underground water

  19. Determination of mercury in carbon black by cold vapor atomic absorption spectrometry.

    PubMed

    Hepp, Nancy M

    2006-01-01

    Recently, a new color additive, D&C Black No. 2, a high-purity furnace black in the general category of carbon blacks, was listed as a color subject to batch certification by the U.S. Food and Drug Administration. A simple procedure was developed to determine mercury (Hg) in D&C Black No. 2, which is limited by specification to not more than 1 ppm Hg. The method uses partial acid digestion followed by cold vapor atomic absorption and was developed by modifying a method used for other color additives. The carbon black samples are treated with a mixture of nitric and hydrochloric acids and heated by microwave in sealed Teflon vessels. The resulting solutions, which are stable to Hg loss for at least 1 week, are diluted and analyzed for Hg using cold vapor atomic absorption spectrometry. Validation was performed by spiking carbon black samples with inorganic Hg (HgNO3) at levels from 0.1 to 1.5 microg/g, and by analyzing 2 standard reference materials. At the specification level of 1 ppm Hg (1 microg Hg/g), the 95% confidence interval was +/-0.01 ppm Hg (0.01 microg Hg/g). The method developed in this study gave good results for very difficult-to-analyze materials, such as coal standard reference materials and carbon black. By eliminating volatility and adsorption factors through the formation of HgCl4(-2) complexes, one can avoid using extremely hazardous acids such as HF and HClO4.

  20. Effects of Solution Physical Properties on Copper and Chromium Signals in Flame Atomic Absorption Spectrometry

    NASA Astrophysics Data System (ADS)

    Rocha, Fàbio R. P.; Nòbrega, Joaquim A.

    1996-10-01

    Instrumental techniques, such as flame atomic absorption spectrometry (FAAS), are frequently used in chemical analysis. Independently of the technique used, the chemical principles must be considered to assure that the analytical results are correct. In FAAS, the most critical step is the sample introduction, since solutions need to be converted in an aerosol (nebulization process) that should contain drops with suitable size to attain the flame. Solution physical properties, such as viscosity and surface tension, can severely affect the analytical signals. Solutions with high viscosity are less easily aspirated and the analyte mass that reach the flame is reduced. The surface tension of the solution affects the size of the drops generated by the nebulization process and can modify the quantity of analyte that attain the flame. This work describes an experiment that allow demonstrating the effects of viscosity and surface tension on analytical signals, using a set of copper solutions prepared in different concentrations of ethanol and chromium solutions prepared in surfactant (tetrapropylammonium bromide) medium. The experiment can be carried out in a 4 h laboratory class and is useful to demonstrate to undergraduate students the effects of samples physical properties on the analytical signals in FAAS.

  1. Liquid phase microextraction and ultratrace determination of cadmium by modified graphite furnace atomic absorption spectrometry.

    PubMed

    Nazari, Saeid

    2009-06-15

    A powerful microextraction technique was used for determination of cadmium in water samples using liquid phase microextraction (LPME) followed by graphite furnace atomic absorption spectrometry (GF-AAS). In a preconcentration step, cadmium was extracted from a 2 ml of its aqueous sample in the pH 7 as 5,7-dibromoquinoline-8-ol (DBQ) complex into a 4 microl drop of benzyl alcohol. After extraction, the micro drop was retracted and directly transferred into a graphite tube modified by [W.Rh.Pd](c). Some effective parameters on extraction and complex formation, such as type and volume of organic solvent, pH, concentration of chelating agent, extraction time and stirring rate were optimized. Under the optimum conditions, the enrichment factor and recovery were 450% and 90%, respectively. The calibration graph was linear in the range of 0.008-1 microg L(-1) with correlation coefficient of 0.9961 under the optimum conditions of the recommended procedure. The detection limit based on the 3Sb criterion was 0.0035 microg L(-1) and relative standard deviation (RSD) for eight replicate measurement of 0.1 microg L(-1) and 0.4 microg L(-1) cadmium was 5.2% and 4.5%, respectively. The characteristic concentration was 0.0032 microg L(-1) equivalent to a characteristic mass of 12.8 fg. In order to evaluate the accuracy and recovery of the presented method the procedure was applied to the analysis of reference materials and seawater.

  2. Determination of trace impurities in titanium dioxide by slurry sampling electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Dong, Huang Mao; Krivan, Viliam; Welz, Bernhard; Schlemmer, Gerhard

    1997-10-01

    A slurry sampling electrothermal atomic absorption spectrometry method for the determination of Al, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, Sr, Tl and Zn in powdered titanium dioxide is described. The behaviour of the titanium matrix in the atomizer and its interferences with the determination of Al, Fe, Co, Ni and Mn were studied. A tungsten carbide modified graphite tube was used to improve the signal shape and the repeatability for the determination of Fe. For all elements, except for Cd and Pb, quantification by a calibration curve established with aqueous standards was possible. No chemical modifier was used throughout in order to minimize contamination. For the contamination risk elements such as Ca, Fe, K, Mg, Na and Zn, the slurry sampling technique allows to achieve limits of detection (3 σ of the blank) 5-20 times lower than the solution technique, resulting for these elements in values of 1, 3, 0.5, 0.5, 0.9 and 2 ng g -1, respectively, and, generally being in the range of 0.2 ng g -1 (Cd) to 10 ng g -1 (Al and Tl). The results obtained by the slurry sampling technique are compared with those of other independent methods including four solution methods and neutron activation analysis.

  3. Monitoring of trace elements in honey from the Republic of Macedonia by atomic absorption spectrometry.

    PubMed

    Stankovska, Elena; Stafilov, Trajce; Sajn, Robert

    2008-07-01

    Contents of Zn, Cu, Fe, Mn, Cd, Na, K, Ca and Mg in 123 honey samples from different regions of the Republic of Macedonia were determined by atomic absorption spectrometry. A microwave digestion system was applied for digestion of the samples. The mean content for the elements determined was found to be: 2.252, 0.696, 1.885, 1.752, 0.004, 29.52, 984.8, 40.11, 18.24 mg kg(-1) for Zn, Cu, Fe, Mn, Cd, Na, K, Ca and Mg, respectively. Based on a comparison of statistical parameters, the spatial distribution of particular elements in Macedonian honey and the results of factor analysis, two natural and one anthropogenic geochemical associations were identified. The natural geochemical associations (Mg, Mn, Ca, K and Fe, Zn, Ca, -K, -Na) are influenced mainly by lithology. The anthropogenic associations (Cd and -Cu) are mostly a result of metallurgical activities, namely lead production in the town of Veles.

  4. Determination of total magnesium in biological samples using electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Hulanicki, Adam; Godlewska, Beata; Brzóska, Malgorzata

    1995-11-01

    Magnesium content is an important diagnostic parameter in medicine. It is recognized that its determination in one compartment is not sufficient for reliable information about the magnesium status in the body. In addition to the common procedures of magnesium determination in blood by flame atomic absorption spectrometry, the procedure of electrothermal atomization has also been developed and applied to the analysis of blood fractions, mononuclear cells and isolated nuclei of liver cells. Electrothermal atomization is preferred in cases where the sample size is limited and the magnesium content low. The total errors are in the order of 3-4%. Various techniques of sample pretreatment have been tested and direct dilution with 0.05 mol l -1 nitric acid was optimal when the samples were not mineralized. The calibration graph based on standards containing albumin was found to give the best results, as the form of magnesium in the samples may influence the ashing and atomization processes. Good agreement was obtained for determination of magnesium in standard serum. The results are compared with those obtained by the standard flame atomization technique.

  5. [Determination of rubidium and cesium in chloride type oilfield water by flame atomic absorption spectrometry].

    PubMed

    Ye, Xiu-Shen; Zhang, Shan-Ying; Li, Hai-Jun; Li, Wu; Wu, Zhi-Jian

    2009-03-01

    Flame atomic absorption spectrometry (FAAS) was applied to the determination of rubidium and cesium in chloride type oilfield water by considering the interferences of the coexistent K+, Na+, Ca2+, and Mg2+ ions, Standard curve method and standard addition method were compared in the determination of rubidium and cesium in the simulated oilfield water and the real oilfield water from the Nanyishan region in Qaidam Basin. Although rubidium and cesium have similar physical-chemical properties, they present different characters during their analyses using the FAAS technique. When the standard addition method was used for the determination of rubidium and cesium in the simulated oilfield water, the results of rubidium were very poor, whereas the results of cesium were satisfactory. When the standard curve method was used for the determination of rubidium and cesium in the simulated oilfield water, the results of both rubidium and cesium were satisfactory within the linear ranges of the standard curves. For the real oilfield water, standard addition method is also only applicable for the determination of cesium with a recovery ranging from 90% to 110%. While standard curve method is applicable for the determination of both rubidium and cesium with a recovery ranging from 90% to 110%.

  6. Determination of Mo and V in multiphase gasoline emulsions by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Santana Sodré dos Santos, Denilson; Paixão Teixeira, Alete; das Graças Andrade Korn, Maria; Sena Gomes Teixeira, Leonardo

    2006-05-01

    This paper proposes an alternative analytical method using electrothermal atomic absorption spectrometry to determine Mo and V in multiphase gasoline emulsions. Samples were prepared by mixing gasoline with a nitric acid solution (0.1% v/v) and two cationic surfactants. The mixture was sonicated, resulting in an emulsive system. Calibration was done by using the aforementioned solutions with added analyte. The detection limits (3 σ) of Mo and V were 0.9 μg l - 1 and 4.7 μg l - 1 , respectively. The accuracy and precision of the proposed method were evaluated by the analysis of samples spiked with metallo-organic standard and the relative standard deviation obtained ranged from 1.2% to 4.4% in samples spiked with 2 μg l - 1 of each metal. The recovery rates varied from 91.2% to 101.6%. The proposed method was applied to determine Mo and V in samples of gasoline from different gas stations.

  7. Optimization of electrothermal atomization parameters for simultaneous multielement atomic absorption spectrometry

    USGS Publications Warehouse

    Harnly, J.M.; Kane, J.S.

    1984-01-01

    The effect of the acid matrix, the measurement mode (height or area), the atomizer surface (unpyrolyzed and pyrolyzed graphite), the atomization mode (from the wall or from a platform), and the atomization temperature on the simultaneous electrothermal atomization of Co, Cr, Cu, Fe, Mn, Mo, Ni, V, and Zn was examined. The 5% HNO3 matrix gave rise to severe irreproducibility using a pyrolyzed tube unless the tube was properly "prepared". The 5% HCl matrix did not exhibit this problem, and no problems were observed with either matrix using an unpyrolized tube or a pyrolyzed platform. The 5% HCl matrix gave better sensitivities with a pyrolyzed tube but the two matrices were comparable for atomization from a platform. If Mo and V are to be analyzed with the other seven elements, a high atomization temperature (2700??C or greater) is necessary regardless of the matrix, the measurement mode, the atomization mode, or the atomizer surface. Simultaneous detection limits (peak height with pyrolyzed tube atomization) were comparable to those of conventional atomic absorption spectrometry using electrothermal atomization above 280 nm. Accuracies and precisions of ??10-15% were found in the 10 to 120 ng mL-1 range for the analysis of NBS acidified water standards.

  8. Determination of silicon in serum and urine by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Huang, Zhuo-er

    1995-09-01

    A sensitive, simple and accurate method for the routine determination of trace silicon in serum and urine by Zeeman electrothermal atomic absorption spectrometry is described. The samples are directly determined after 20-fold dilution of serum and 100-fold dilution of urine. No L'vov platform is used. The signal enhancement of silicon atomization in pyrolytic graphite coated graphite tubes is achieved by using a mixture of calcium chloride and lanthanum nitrate as chemical modifier. The interferences arising from the biological matrices have been eliminated by the addition of ammonium dihydrogenphosphate in the sample solutions. The aqueous calibration curve is linear to at least 300 μg l -1, the characteristic mass is 37 pg (integrated absorbance signal), whereas the detection limit (3SD) is 1.5 μg l -1 for silicon in both diluted serum and urine samples. The recoveries of silicon added to the diluted samples are 101 ± 1.8% for sera and 98.2 ± 3.5% for the urine specimens, independent of the dilution ratio. The silicon measurement results for the serum and urine from healthy adults and for the serum from the patients with chronic renal failure on hemodialysis are presented.

  9. Determination of total gaseous lead in the atmosphere by honeycomb denuder/electrothermal atomic absorption spectrometry.

    PubMed

    Zhang, Bicheng; Wu, Tao; Yu, Jimmy C

    2005-09-01

    A technique is described for the determination of total gaseous lead in the atmosphere by honeycomb denuder collection, followed by an electrothermal atomic absorption spectrometry (ETAAS) measurement. The collection efficiency of the honeycomb denuder in which a solution containing 2% HNO3/2% glycerine/1% ammonium dihydrogenphosphate was coated for trapping the gaseous lead in the atmosphere was 98.8%. The linear absorbance response was obtained for a concentration range of 0-1.39 microg m(-3) of lead in the atmosphere. A precision of 4.8% RSD (peak-height absorbance, n = 11) for an aqueous solution of 1 ng of lead standard, characteristic masses (CM) of 23 pg and detection limit (3sigma) of 54 pg for an aqueous solution of 0.01 ng lead standard was achieved with 100 microg ammonium dihydrogenphosphate as a chemical modifier. The average recovery of lead in three standard samples prepared by the independent digestion of NIST SRM 1648 (Urban Particulate Matter) using our analytical system was 97.8%. The total content of the gaseous lead in the atmosphere of our laboratories was 0.35-0.38 microg m(-3).

  10. Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry

    PubMed Central

    Zelinková, Hana; Červenka, Rostislav; Komárek, Josef

    2012-01-01

    Tetramethylene dithiocarbamate (TMDTC), diethyldithiocarbamate (DEDTC), and thiourea were investigated as stabilizing agents for calibration purposes in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS). These agents were used for complexation of mercury in calibration solutions and its thermal stabilization in a solid sampling platform. The calibration solutions had the form of methyl isobutyl ketone (MIBK) extracts or MIBK-methanol solutions with the TMDTC and DEDTC chelates and aqueous solutions with thiourea complexes. The best results were obtained for MIBK-methanol solutions in the presence of 2.5 g L−1 TMDTC. The surface of graphite platforms for solid sampling was modified with palladium or rhenium by using electrodeposition from a drop of solutions. The Re modifier is preferable due to a higher lifetime of platform coating. A new SS-ETAAS procedure using the direct sampling of solid samples into a platform with an Re modified graphite surface and the calibration against MIBK-methanol solutions in the presence of TMDTC is proposed for the determination of mercury content in solid environmental samples, such as soil and plants. PMID:22654606

  11. Determination of lead in fine particulates by slurry sampling electrothermal atomic absorption spectrometry.

    PubMed

    Yu, J C; Ho, K F; Lee, S C

    2001-01-02

    A simple method for determining lead in fine particulates (PM2.5) by using electrothermal atomic absorption spectrometry (ETAAS) has been developed. Particulates collected on Nuclepore filter by using a dichotomous sampler were suspended in diluted nitric acid after ultrasonic agitation. The dislodging efficiency is nearly 100% after agitation for 5 min. In order to study the suspension behavior of PM2.5 in solvents, a Brookhaven ZetaPlus Particle Size Analyzer was used to determine the particle size distribution and suspension behavior of air particulates in the solvent. The pre-digestion and modification effect of nitric acid would be discussed. Palladium was added as a chemical modifier and the temperature program of ETAAS was changed in order to improve the recovery. The slurry was introduced directly into a graphite tube for atomization. The metal content in the sample was determined by the standard addition method. In addition, a conventional acid digestion procedure was applied to verify the efficiency of the slurry sampling method. It offers a quick and efficient alternative method for heavy metal characterization in fine particulates.

  12. Determination of tellurium in indium antimonide semiconductor material by electrothermal atomic absorption spectrometry.

    PubMed

    Shiue, M Y; Sun, Y C; Yang, M H

    2001-08-01

    A method for the determination of the dopant concentration of tellurium in dissolved indium antimonide semiconductor material by electrothermal atomic absorption spectrometry (ETAAS) was developed. Efforts were made to investigate the optimal conditions of the furnace heating program and the effect of palladium modifier on the variation of tellurium and the background absorbance. According to the results obtained, the presence of palladium chemical modifier in the analysis of indium antimonide allowed the successful retention of tellurium in the graphite tube, and the optimum mass of palladium modifier was found to be dependent on the sample matrix concentration. The absorbance profile of tellurium and the background level were significantly improved when a pyrolysis temperature of 1100 degrees C and an atomization temperature of 2200 degrees C were employed in the optimized heating program. With the use of this method, a detection limit of 0.8 microg g(-1) tellurium in indium antimonide could be achieved. The applicability of the proposed method was evaluated by comparison with two independent methods, i.e. slurry sampling-ETAAS and ICP-MS. From the good agreement between the results, it was demonstrated that the proposed method is suitable for the determination of typical dopant concentrations of tellurium in indium antimonide.

  13. Determination of nickel, chromium and cobalt in wheat flour using slurry sampling electrothermal atomic absorption spectrometry.

    PubMed

    González, M; Gallego, M; Valcárcel, M

    1999-05-01

    The slurry technique was applied to the determination of Ni, Cr and Co in wheat flour by electrothermal atomic absorption spectrometry (ETAAS). The influence of the graphite furnace temperature programme was optimized. Optimum sensitivity was obtained by using a mixture of 15% HNO(3)-10% H(2)O(2) as suspended medium for a 3% w/v slurry in the determination of Ni; lower concentrations of HNO(3) were necessary for the determination of Co and Cr (viz. 5 and 10%). The precision of direct analyses of the slurries was improved by using mechanical agitation between measurements; thus, the RSD of the measurements was ca. 5% for repeatability. The direct slurry sampling (SS) technique is suitable for the determination of Ni and Cr in wheat flour samples at levels of 150-450 and 30-72 ng g(-1), respectively, as it provides results similar to those obtained by ashing the sample. However, the typically low level of Co in these samples precluded its determination by the proposed method (the study was made in an SRM spiked wholemeal flour), at least in those samples that were contaminated with elevated concentrations of the metal (viz. more than 90 ng of Co per g of flour). The method provides a relative standard deviation of 6, 8, and 4% for Ni, Cr, and Co, respectively.

  14. Handling complex effects in slurry-sampling-electrothermal atomic absorption spectrometry by multivariate calibration.

    PubMed

    Felipe-Sotelo, M; Cal-Prieto, M J; Gómez-Carracedo, M P; Andrade, J M; Carlosena, A; Prada, D

    2006-07-07

    Analysis of solid samples by slurry-sampling-electrothermal atomic absorption spectrometry (SS-ETAAS) can imply spectral and chemical interferences caused by the large amount of concomitants introduced into the graphite furnace. Sometimes they cannot be solved using stabilized temperature platform furnace (STPF) conditions or typical approaches (previous sample ashing, use of chemical modifiers, etc.), which are time consuming and quite expensive. A new approach to handle interferences using multivariate calibrations (partial least squares, PLS, and artificial neural networks, ANN) is presented and exemplified with a real problem consisting on determining Sb in several solid matrices (soils, sediments and coal fly ash) as slurries by ETAAS. Experimental designs were implemented at different levels of Sb to develop the calibration matrix and assess which concomitants (seven ions were considered) modified the atomic signal mostly. They were Na+ and Ca2+ and they induced simultaneous displacement, depletion (enhancement) and broadening of the atomic peak. Here it is shown that these complex effects can be handled in a reliable, fast and cost-effective way to predict the concentration of Sb in slurry samples of several solid matrices. The method was validated predicting the concentrations of five certified reference materials (CRMs) and studying its robustness to current ETAAS problems. It is also shown that linear PLS can handle eventual non-linearities and that its results are comparable to more complex (non-linear) models, as those from ANNs.

  15. Determination of arsenic in a nickel alloy by flow injection hydride generation atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Hanna, C. P.; Tyson, J. F.; Offley, S. G.

    1992-08-01

    The development of a method for the direct determination of trace arsenic quantities in nickel alloy digests, by flow injection hydride generation atomic absorption spectrometry, is described. An optimization study of the manifold and chemical parameters produced system performance, in terms of tolerance of the nickel matrix and sensitivity, such that matrix removal and pre-reduction of As(V) to As (III) prior to arsine generation were eliminated. Full recovery of the As(V) signal from a solution containing 5 ng ml -1 in the presence of 60 μg ml -1 nickel was obtained. Validation of the method was achieved by analyzing a British Chemical Standard (BCS) Certified Reference Material (CRM) #346 IN nickel alloy containing arsenic at a concentration of 50 μg g -1. Following dissolution in nitric and hydrofluoric acids by a microwave assisted procedure, the only subsequent preparation required was dilution by the appropriate factor. Up to 60 injections h -1 may be made, with a detection limit of 0.5 ng ml -1 arsenic (250 pg absolute) as As(V) in a 500 μl sample. The peak height characteristic concentration is 0.46 ng ml -1, with a relative standard deviation of 3.5% for a 10 ng ml -1 As(V) standard ( n = 6).

  16. Determination of nickel in active pharmaceutical ingredients by electrothermal atomic absorption spectrometry.

    PubMed

    Bubnič, Zoran; Urleb, Uroš; Kreft, Katjuša; Veber, Marjan

    2010-03-01

    An electrothermal atomic absorption spectrometric procedure for the determination of nickel in active pharmaceutical ingredients was developed. Since the recoveries of nickel by the direct dissolution of samples in diluted nitric acid were low and caused errors in the determination of Ni in pharmaceutical samples, different approaches for sample pre-treatment were examined. It was found that the microwave digestion was the most suitable way for sample preparation. Various combinations of digestion agents and different microwave conditions were tested. The combination of nitric acid and hydrogen peroxide was found to be the most appropriate. The validity of the method was evaluated by recovery studies of spiked samples and by the comparison of the results obtained by inductively coupled plasma mass spectrometry (ICP-MS). The recovery ranged from 87.5 to 104.0% and a good agreement was achieved between both methods. The detection limit and the limit of quantification were 0.6 and 2.1 µg g-1 respectively. The precision of the method was confirmed by the determination of Ni in the spiked samples and was below 4%, expressed in terms of a relative standard deviation. The method was applied to the determination of nickel in production samples of active pharmaceutical ingredients and intermediates.

  17. Determination of mercury distribution inside spent compact fluorescent lamps by atomic absorption spectrometry.

    PubMed

    Rey-Raap, Natalia; Gallardo, Antonio

    2012-05-01

    In this study, spent compact fluorescent lamps were characterized to determine the distribution of mercury. The procedure used in this research allowed mercury to be extracted in the vapor phase, from the phosphor powder, and the glass matrix. Mercury concentration in the three phases was determined by the method known as cold vapor atomic absorption spectrometry. Median values obtained in the study showed that a compact fluorescent lamp contained 24.52±0.4ppb of mercury in the vapor phase, 204.16±8.9ppb of mercury in the phosphor powder, and 18.74±0.5ppb of mercury in the glass matrix. There are differences in mercury concentration between the lamps since the year of manufacture or the hours of operation affect both mercury content and its distribution. The 85.76% of the mercury introduced into a compact fluorescent lamp becomes a component of the phosphor powder, while more than 13.66% is diffused through the glass matrix. By washing and eliminating all phosphor powder attached to the glass surface it is possible to classified the glass as a non-hazardous waste.

  18. Investigation on binding of nitric oxide to horseradish peroxidase by absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Qiang, Li; Zhu, Shuhua; Ma, Hongmei; Zhou, Jie

    2010-01-01

    Binding of nitric oxide to horseradish peroxidase (HRP) has been investigated by absorption spectrometry in 0.2 M anaerobic phosphate buffer solution (pH 7.4). Based on this binding equilibrium, a model equation for evaluating the binding constant of nitric oxide to HRP is developed and the binding constant is calculated to be (1.55 ± 0.06) × 10 4 M -1, indicating that HRP can form a stable complex with nitric oxide. The type of inhibition by nitric oxide is validated on the basis of studying initial reaction rates of HRP-catalyzed oxidation of guaiacol in the presence of hydrogen peroxide and nitric oxide. The inhibition mechanism is found to follow an apparent non-competitive inhibition by Lineweaver-Burk method. Based on this kinetic mechanism, the binding constant is also calculated to be (5.22 ± 0.06) × 10 4 M -1. The values of the binding constant determined by the two methods are almost identical. The non-competitive inhibition model is also applicable to studying the effect of nitric oxide on other metalloenzymes, which catalyze the two-substrate reaction with the "ping-pong" mechanism.

  19. Determination of some antihistaminic drugs by atomic absorption spectrometry and colorimetric methods.

    PubMed

    El-Kousy, N; Bebawy, L I

    1999-08-01

    Atomic absorption spectrometry (AAS) and colourimetric methods have been developed for the determination of pizotifen (I), ketotifen (II) and loratadine (III). The first method depends on the reaction of the three drugs (I); (II) and (III) with cobalt thiocyanate reagent at pH 2 to give ternary complexes. These complexes are readily extracted with organic solvent and estimated by indirect atomic absorption method via the determination of the cobalt content in the formed complex after extraction in 0.1 M hydrochloric acid. It was found that the three drugs can be determined in the concentration ranges from 10 to 74, 12 to 95 and 10 to 93 microg ml(-1) with mean percentage recovery of 99.71+/-0.87, 99.70+/-0.79 and 99.62+/-0.75%, respectively. The second method is based on the formation of orange red ion pairs as a result of the reaction between (I); (II) and (III) and molybdenum thiocyanate with maximum absorption at 469.5 nm in dichloromethane. Appropriate conditions were established for the colour reaction. Under the proposed conditions linearity was obeyed in the concentration ranges 3.5-25, 5-37.5 and 2.5-22.5 microg ml(-1) with mean percentage recovery of 99.60+/-0.41, 100.11+/-0.43 and 99.31+/-0.47% for (I): (II) and (III), respectively. The third method depends on the formation of radical ion using 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ). The colour formed was measured at 588 nm for the three drugs (I); (II) and (III), respectively. The method is valid in concentration range 10-80 microg ml(-1) with mean percentage recovery 99.75+/-0.44, 99.94+/-0.72 and 99.17+/-0.36% for (I); (II) and (III), respectively. The proposed methods were applied to the analysis of pharmaceutical preparations. The results obtained were statistically analysed and compared with those obtained by applying the official and reference methods.

  20. Selection of the optimal combination of water vapor absorption lines for detection of temperature in combustion zones of mixing supersonic gas flows by diode laser absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Mironenko, V. R.; Kuritsyn, Yu. A.; Bolshov, M. A.; Liger, V. V.

    2016-12-01

    Determination of a gas medium temperature by diode laser absorption spectrometry (DLAS) is based on the measurement of integral intensities of the absorption lines of a test molecule (generally water vapor molecule). In case of local thermodynamic equilibrium temperature is inferred from the ratio of the integral intensities of two lines with different low energy levels. For the total gas pressure above 1 atm the absorption lines are broadened and one cannot find isolated well resolved water vapor absorption lines within relatively narrow spectral interval of fast diode laser (DL) tuning range (about 3 cm-1). For diagnostics of a gas object in the case of high temperature and pressure DLAS technique can be realized with two diode lasers working in different spectral regions with strong absorption lines. In such situation the criteria of the optimal line selection differs significantly from the case of narrow lines. These criteria are discussed in our work. The software for selection the optimal spectral regions using the HITRAN-2012 and HITEMP data bases is developed. The program selects spectral regions of DL tuning, minimizing the error of temperature determination δT/T, basing on the attainable experimental error of line intensity measurement δS. Two combinations of optimal spectral regions were selected - (1.392 & 1.343 μm) and (1.392 & 1.339 μm). Different algorithms of experimental data processing are discussed.

  1. Sample pre-treatment methods for the trace elements determination in seafood products by atomic absorption spectrometry.

    PubMed

    Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio; Bermejo-Barrera, Adela

    2002-07-03

    Different sample pre-treatments for seafood products have been compared with determine trace elements (As, Cd, Cr, Cu, Fe, Mg, Mn, Ni, Pb, Se and Zn) by flame atomic absorption spectrometry (FAAS) and electrothermal atomic absorption spectrometry (ETAAS). Classic pre-treatments as microwave assisted-acid digestion and the slurry sampling technique were compared with new procedures such as microwave energy or ultrasound energy assisted-acid leaching process and enzymatic hydrolysis methodologies based on the use of pronase E. The methods were applied to DORM-1 and DOLT-1 reference materials with certified contents for the studied elements. The Student-Newman-Keuls (SNK) method was used to compare with element concentration means obtained with each sample pre-treatment and also the certified concentration means in both reference materials. Multivariate techniques such as principal components analysis (PCA) was also applied to comparative purposes.

  2. Robotized sampling device for graphite furnace atomic absorption spectrometry slurry analysis with Varian SpectrAA instruments

    NASA Astrophysics Data System (ADS)

    Hoenig, Michel; Cilissen, Anne

    1993-08-01

    There is a growing interest in the determination by electrothermal atomic absorption spectrometry (ETAAS) of elements in solid samples without a dissolution stage, to avoid contamination and losses during the preparation of the sample. This approach may be particularly convenient when only small amounts of sample are available. Details of the above-mentioned program for the adaptation of the Gilson sample changer to Varian SpectrAA systems (X,Y,Z positions, timings etc.) are available on request.

  3. Determination of cadmium in biodiesel using microemulsion and electrothermal atomization atomic absorption spectrometry.

    PubMed

    Lima, Adriana S; Silva, Deise G; Teixeira, Leonardo S G

    2015-01-01

    This work aimed to prepare biodiesel microemulsions for the subsequent quantification of cadmium via graphite furnace atomic absorption spectrometry (GFAAS). The biodiesel samples were prepared using n-propanol as an emulsifier, 10% (v/v) nitric acid as the aqueous phase, and biodiesel. Pseudoternary phase diagrams were constructed to determine the microemulsion region with the specified components. The optimized conditions for microemulsion formation were 57.6% (v/v) n-propanol, 21.2% (v/v) biodiesel, and 21.2% (v/v) nitric acid solution. The stability of the microemulsified system was investigated using aqueous and organic standards, and the system was found to be stable for at least 240 min. The applied pyrolysis and atomization temperatures were 800 and 2000 °C, respectively, and 5 μg of aluminum was used as the chemical modifier. The obtained limits of detection and quantification were 0.2 and 0.5 μg kg(-1), respectively, and the characteristic mass was 1.6 pg. The precision, expressed as the relative standard deviation (% R.S.D., n = 10), was 2.5% for a sample with a cadmium concentration of 6.5 μg kg(-1). The accuracy was determined from addition and recovery experiments, with results varying from 93 to 108% recovery. This study demonstrates that the proposed method based on the use of a microemulsion formation in sample preparation can be applied as an efficient alternative for the determination of cadmium in biodiesel by GFAAS. Cadmium determination in biodiesel samples of different origins (soybean, corn, cotton, and sunflower) was evaluated after acid digestion using the inductively coupled plasma-mass spectrometry (ICP-MS) technique, and the obtained results were compared to the results obtained using the proposed method. The paired t test (95% confidence level) did not show significant differences. The concentrations of cadmium found ranged from 5.3 to 8.0 μg kg(-1).

  4. Cadmium, copper, lead, and zinc determination in precipitation: A comparison of inductively coupled plasma atomic emission spectrometry and graphite furnace atomization atomic absorption spectrometry

    USGS Publications Warehouse

    Reddy, M.M.; Benefiel, M.A.; Claassen, H.C.

    1987-01-01

    Selected trace element analysis for cadmium, copper, lead, and zinc in precipitation samples by inductively coupled plasma atomic emission Spectrometry (ICP) and by atomic absorption spectrometry with graphite furnace atomization (AAGF) have been evaluated. This task was conducted in conjunction with a longterm study of precipitation chemistry at high altitude sites located in remote areas of the southwestern United States. Coefficients of variation and recovery values were determined for a standard reference water sample for all metals examined for both techniques. At concentration levels less than 10 micrograms per liter AAGF analyses exhibited better precision and accuracy than ICP. Both methods appear to offer the potential for cost-effective analysis of trace metal ions in precipitation. ?? 1987 Springer-Verlag.

  5. Evaluation of propolis polyphenols absorption in humans by liquid chromatography/tandem mass spectrometry.

    PubMed

    Gardana, Claudio; Simonetti, Paolo; Berti, Cristiana; Pietta, Piergiorgio

    2007-01-01

    Propolis has various biological activities such as antibacterial, antiviral, antioxidant, immunostimulating and antiinflammatory, which are generally ascribed to the polyphenolic fraction. The aim of this study was to evaluate the absorption of the main polyphenols [caffeic acid (CA), pinobanksin-5methyl ether (P-5ME), pinobanksin (Pb), chrysin (C), pinocembrin (P), galangin (G), pinobanksin-3-acetate, pinobanksin esters and caffeic acid phenylethyl ester (CAPE)] from a dewaxed and standardized extract of propolis (EPID). Fifteen healthy volunteers consumed 5 mL EPID in water, corresponding to 125 mg of flavonoids. Blood samples were collected before, each hour for 8 h and 24 h after EPID intake. After deconjugation by beta-glucuronidase/sulfatase the plasma samples were analyzed by a selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method using morin as internal standard (I.S.). A kinetic profile characterized by two t(max), respectively at 1 h and about 5 h post-ingestion, was observed in all the subjects. The two peaks may be due to enterohepatic cycling. Among the various polyphenols ingested, only P-5ME, Pb, C, P and G were detected in plasma and C(max)t(1h) were 65.7 +/- 13.3, 46.5 +/- 12.7, 79.5 +/- 18.6, 168.1 +/- 16.3 and 113.7 +/- 16.8 ng/mL, respectively. These levels decreased significantly after 8 h and were no longer detectable 24 h after EPID intake. The recovery of the extraction for CA, Pb, C, P, G and I.S. from spiked plasma was 95.2 +/- 3.1, 93.1 +/- 3.6, 91 +/- 2.5, 96.4 +/- 4.2, 93.4 +/- 2.4 and 85.5 +/- 2.4%, respectively. The results of this study evidence that flavonoids from EPID are absorbed, metabolized and Pb-5ME and G seem to have apparent absorption, measured as (AUC/dose), higher than C, P and Pb.

  6. Feasibility of filter atomization in high-resolution continuum source atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Heitmann, Uwe; Becker-Ross, Helmut; Katskov, Dmitri

    2006-03-01

    A prototype spectrometer for high-resolution continuum source atomic absorption spectrometry (HR-CS AAS), built at ISAS Berlin, Germany, was combined with a graphite filter atomizer (GFA), earlier developed at TUT, Pretoria, South Africa. The furnace and auto-sampler units from a commercial AA spectrometer, model AAS vario 6 (Analytik Jena AG, Jena, Germany), were employed in the instrument. Instead of conventional platform tube, the GFA was used to provide low measurement susceptibility to interferences and short determination cycle. The GFA was modified according to the design of the furnace unit and optimal physical parameters of its components (filter and collector) found. Afterwards, optimal GFA was replicated and tested to outline analytical performances of the HR-CS GFA AA spectrometer in view of prospects of multi-element analysis. In particular, reproducibility of performances, repeatability of analytical signals, lifetime, temperature limit and duration of the measurement cycle were examined, and elements available for determination justified. The results show that the peak area of the atomic absorption signal is reproduced in various GFA copies within ± 4% deviation range. The GFA can stand temperatures of 2800 °C with 6 s hold time for 55 temperature cycles, and 2700 °C (8 s) for about 200 cycles. Only the external tube is prone to destruction while the filter and collector do not show any sign of erosion caused by temperature or aggressive matrix. Analytical signals are affected insignificantly by tube aging. Repeatability of the peak area remains within 1.1-1.7% RSD over more than hundred determination cycles. Peak areas are proportional to the sample volume of injected organic and inorganic liquids up to at least 50 μL. The drying stage is combined with hot sampling and cut down to 15-20 s. The list of metals available for determination with full vapor release includes Al, Co, Cr, Ni, Pt as well as more volatile metals. Characteristic masses at

  7. Direct analysis of reference biofluids by coupled in situ electrodeposition-electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Matousek, Jaroslav P.; Powell, Kipton J.

    1999-12-01

    The application of coupled in situ electrodeposition-electrothermal atomic absorption spectrometry (ED-ETAAS) to the determination of Pb in biological standard reference materials is described. In situ electrodeposition at a cell voltage of 3.0 V from 25-μl samples onto electrodeposited Pd is used to quantitatively separate the analyte from blood and urine matrices. With subsequent withdrawal of spent electrolyte, this overcomes the atomisation problems inherent with high salt and organic contents. ED-ETAAS is applied with minimal sample pre-treatment (acidification). The electrolysis process aids decomposition of the organic matrix, and the release of trace elements. Evolution of H 2 at the cathode counters fouling of the Pd modifier surface. The palladium deposit is renewed in situ for each determination. For AMI certified lyophilised blood, diluted 1+3 with 0.1 M HCl (18.1 μg/l Pb), the R.S.D. was 3.0% (peak height; n=5) and the detection limit (3 σ blank; n=5) was 1.5 μg/l. Results for certified blood samples were AMI 72.3±4.3 μg/l (certified 76.2±7.6 μg/l) and Seronorm 34.2±2.0 μg/l (36±4 μg/l). The result for NIST SRM 2670 normal urine acidified to 1% HNO 3 was 8.1±0.6 μg/l (recommended value 10 μg/l).

  8. Determination of tellurium by hydride generation with in situ trapping flame atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Matusiewicz, Henryk; Krawczyk, Magdalena

    2007-03-01

    The analytical performance of coupled hydride generation — integrated atom trap (HG-IAT) atomizer flame atomic absorption spectrometry (FAAS) system was evaluated for determination of Te in reference material (GBW 07302 Stream Sediment), coal fly ash and garlic. Tellurium, using formation of H 2Te vapors, is atomized in air-acetylene flame-heated IAT. A new design HG-IAT-FAAS hyphenated technique that would exceed the operational capabilities of existing arrangements (a water-cooled single silica tube, double-slotted quartz tube or an "integrated trap") was investigated. An improvement in detection limit was achieved compared with using either of the above atom trapping techniques separately. The concentration detection limit, defined as 3 times the blank standard deviation (3 σ), was 0.9 ng mL - 1 for Te. For a 2 min in situ pre-concentration time (sample volume of 2 mL), sensitivity enhancement compared to flame AAS, was 222 fold, using the hydride generation — atom trapping technique. The sensitivity can be further improved by increasing the collection time. The precision, expressed as RSD, was 7.0% ( n = 6) for Te. The designs studied include slotted tube, single silica tube and integrated atom trap-cooled atom traps. The accuracy of the method was verified using a certified reference material (GBW 07302 Stream Sediment) by aqueous standard calibration curves. The measured Te contents of the reference material was in agreement with the information value. The method was successfully applied to the determination of tellurium in coal fly ash and garlic.

  9. [Determination of metals in Ginkgo biloba leaves by atomic absorption spectrometry with microwave digestion].

    PubMed

    Jiang, Bo; Jiang, Guo-Bin; Liu, Chang-Jian; Ma, Kun; Jin, Li-Ming; Gao, Jiang-Mei

    2010-03-01

    Microwave digestion technique was used in the decomposition of Ginkgo biloba leaves from six different trees at the same age in the same area. HNO3-H2O2 (5 : 1 v/v) was used as microwave digestion agent at a suitable temperature and time. The contents of Ca, Mg, K, Na, Cu, Zn and Zn/Cu were determined by flame atomic absorption spectrometry to study the distribution rule of metallic elements in the trees at the same age and in the same area. The recovery ratio ranged from 95.2% to 104.6%. The results showed that there were certain differences between different trees in the distribution of metallic elements. The contents of calcium were from 39 586 to 48 320 microg x g(-1), and those of magnesium from 10 076 to 12 918 microg x g(-1), of potassium from 2 004 to 5 240 microg x g(-1), of sodium from 9.05 to 35.30 microg x g(-1), and of copper from 1.50 to 3.05 microg x g(-1), while Zn/Cu values were from 2.68 to 5.93 in the leaves of 6 different trees in the same growing area. Therefore there were abounding calcium, magnesium and potassium, while the content of sodium and Zn/Cu values were lower, and the metal contents were different in the leaves. The experimental results provided useful bases for studying the distribution rule of metallic elements in Ginkgo biloba leaves, the relationship between the contents of calcium, magnesium, potassium and sodium and the Zn/Cu value in ginkgo biloba leaves and the treatment for cardio-cerebral vascular disease.

  10. Determination of mercury distribution inside spent compact fluorescent lamps by atomic absorption spectrometry

    SciTech Connect

    Rey-Raap, Natalia

    2012-05-15

    Highlights: Black-Right-Pointing-Pointer New treatments for CFL are required considering the aim of Directive 202/96/CE. Black-Right-Pointing-Pointer It is shown that most of the mercury introduced into a CFL is in the phosphor powder. Black-Right-Pointing-Pointer Experimental conditions for microwave-assisted sample digestion followed by AAS measurements are described. Black-Right-Pointing-Pointer By washing the glass it is possible to reduce the concentration below legal limits. - Abstract: In this study, spent compact fluorescent lamps were characterized to determine the distribution of mercury. The procedure used in this research allowed mercury to be extracted in the vapor phase, from the phosphor powder, and the glass matrix. Mercury concentration in the three phases was determined by the method known as cold vapor atomic absorption spectrometry. Median values obtained in the study showed that a compact fluorescent lamp contained 24.52 {+-} 0.4 ppb of mercury in the vapor phase, 204.16 {+-} 8.9 ppb of mercury in the phosphor powder, and 18.74 {+-} 0.5 ppb of mercury in the glass matrix. There are differences in mercury concentration between the lamps since the year of manufacture or the hours of operation affect both mercury content and its distribution. The 85.76% of the mercury introduced into a compact fluorescent lamp becomes a component of the phosphor powder, while more than 13.66% is diffused through the glass matrix. By washing and eliminating all phosphor powder attached to the glass surface it is possible to classified the glass as a non-hazardous waste.

  11. Total Absorption Gamma-ray Spectrometer (TAGS) Intensity Distributions from INL's Gamma-Ray Spectrometry Center

    DOE Data Explorer

    Greenwood, R. E.

    A 252Cf fission-product source and the INL on-line isotope separator were used to supply isotope-separated fission-product nuclides to a total absorption -ray spectrometer. This spectrometer consisted of a large (25.4-cm diameter x 30.5-cm long) NaI(Tl) detector with a 20.3-cm deep axial well in which is placed a 300-mm2 x 1.0-mm Si detector. The spectra from the NaI(Tl) detector are collected both in the singles mode and in coincidence with the B-events detected in the Si detector. Ideally, this detector would sum all the energy of the B- rays in each cascade following the population of daughter level by B- decay, so that the event could be directly associated with a particular daughter level. However, there are losses of energy from attenuation of the rays before they reach the detector, transmission of rays through the detector, escape of secondary photons from Compton scattering, escape of rays through the detector well, internal conversion, etc., and the measured spectra are thus more complicated than the ideal case and the analysis is more complex. Analysis methods have been developed to simulate all of these processes and thus provide a direct measure of the B- intensity distribution as a function of the excitation energy in the daughter nucleus. These data yield more accurate information on the B- distribution than conventional decay-scheme studies for complex decay schemes with large decay energies, because in the latter there are generally many unobserved and observed but unplaced rays. The TAGS data have been analyzed and published [R. E. Greenwood et al., Nucl Instr. and metho. A390(1997)] for 40 fission product-nuclides to determine the B- intensity distributions. [Copied from the TAGS page at http://www.inl.gov/gammaray/spectrometry/tags.shtml]. Those values are listed on this page for quick reference.

  12. Determination and interference studies of bismuth by tungsten trap hydride generation atomic absorption spectrometry.

    PubMed

    Kula, Ibrahim; Arslan, Yasin; Bakirdere, Sezgin; Titretir, Serap; Kendüzler, Erdal; Ataman, O Yavuz

    2009-11-15

    The determination of bismuth requires sufficiently sensitive procedures for detection at the microg L(-1) level or lower. W-coil was used for on-line trapping of volatile bismuth species using HGAAS (hydride generation atomic absorption spectrometry); atom trapping using a W-coil consists of three steps. Initially BiH(3) gas is formed by hydride generation procedure. The analyte species in vapor form are transported through the W-coil trap held at 289 degrees C where trapping takes place. Following the preconcentration step, the W-coil is heated to 1348 degrees C; analyte species are released and transported to flame-heated quartz atom cell where the atomic signal is formed. In our study, interferences have been investigated in detail during Bi determination by hydride generation, both with and without trap in the same HGAAS system. Interferent/analyte (mass/mass) ratio was kept at 1, 10 and 100. Experiments were designed for carrier solutions having 1.0M HNO(3). Interferents such as Fe, Mn, Zn, Ni, Cu, As, Se, Cd, Pb, Au, Na, Mg, Ca, chloride, sulfate and phosphate were examined. The calibration plot for an 8.0 mL sampling volume was linear between 0.10 microg L(-1) and 10.0 microg L(-1) of Bi. The detection limit (3s/m) was 25 ng L(-1). The enhancement factor for the characteristic concentration (C(o)) was found to be 21 when compared with the regular system without trap, by using peak height values. The validation of the procedure was performed by the analysis of the certified water reference material and the result was found to be in good agreement with the certified values at the 95% confidence level.

  13. Determination of As, Cd, Cu, Hg and Pb in biological samples by modern electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Sardans, Jordi; Montes, Fernando; Peñuelas, Josep

    2010-02-01

    Pollution from heavy metals has increased in recent decades and has become an important concern for environmental agencies. Arsenic, cadmium, copper, mercury and lead are among the trace elements that have the greatest impact and carry the highest risk to human health. Electrothermal atomic absorption spectrometry (ETAAS) has long been used for trace element analyses and over the past few years, the main constraints of atomic absorption spectrometry (AAS) methods, namely matrix interferences that provoked high background absorption and interferences, have been reduced. The use of new, more efficient modifiers and in situ trapping methods for stabilization and pre-concentration of these analytes, progress in control of atomization temperatures, new designs of atomizers and advances in methods to correct background spectral interferences have permitted an improvement in sensitivity, an increase in detection power, reduction in sample manipulation, and increase in the reproducibility of the results. These advances have enhanced the utility of Electrothermal atomic absorption spectrometry (ETAAS) for trace element determination at μg L -1 levels, especially in difficult matrices, giving rise to greater reproducibility, lower economic cost and ease of sample pre-treatment compared to other methods. Moreover, the recent introduction of high resolution continuum source Electrothermal atomic absorption spectrometry (HR-CS-ETAAS) has facilitated direct solid sampling, reducing background noise and opening the possibility of achieving even more rapid quantitation of some elements. The incorporation of flow injection analysis (FIA) systems for automation of sample pre-treatment, as well as chemical vapor generation renders (ETAAS) into a feasible option for detection of As and Hg in environmental and food control studies wherein large numbers of samples can be rapidly analyzed. A relatively inexpensive approach with low sample consumption provide additional advantages of

  14. Speciation analysis of arsenic in biological matrices by automated hydride generation-cryotrapping-atomic absorption spectrometry with multiple microflame quartz tube atomizer (multiatomizer).

    EPA Science Inventory

    This paper describes an automated system for the oxidation state specific speciation of inorganic and methylated arsenicals by selective hydride generation - cryotrapping- gas chromatography - atomic absorption spectrometry with the multiatomizer. The corresponding arsines are ge...

  15. Mercury in Environmental and Biological Samples Using Online Combustion with Sequential Atomic Absorption and Fluorescence Measurements: A Direct Comparison of Two Fundamental Techniques in Spectrometry

    ERIC Educational Resources Information Center

    Cizdziel, James V.

    2011-01-01

    In this laboratory experiment, students quantitatively determine the concentration of an element (mercury) in an environmental or biological sample while comparing and contrasting the fundamental techniques of atomic absorption spectrometry (AAS) and atomic fluorescence spectrometry (AFS). A mercury analyzer based on sample combustion,…

  16. Simultaneous determination of cadmium and lead in wine by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Freschi, Gian P. G.; Dakuzaku, Carolina S.; de Moraes, Mercedes; Nóbrega, Joaquim A.; Gomes Neto, José A.

    2001-10-01

    A method has been developed for the direct simultaneous determination of Cd and Pb in white and red wine by electrothermal atomic absorption spectrometry (ET-AAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of both analytes during pyrolysis and atomization stages were investigated in 0.028 mol l -1 HNO 3 and in 1+1 v/v diluted wine using mixtures of Pd(NO 3) 2+Mg(NO 3) 2 and NH 4H 2PO 4+Mg(NO 3) 2 as chemical modifiers. With 5 μg Pd+3 μg Mg as the modifiers and a two-step pyrolysis (10 s at 400°C and 10 s at 600°C), the formation of carbonaceous residues inside the atomizer was avoided. For 20 μl of sample (wine+0.056 mol l -1 HNO 3, 1+1, v/v) dispensed into the graphite tube, analytical curves in the 0.10-1.0 μg l -1 Cd and 5.0-50 μg l -1 Pb ranges were established. The characteristic mass was approximately 0.6 pg for Cd and 33 pg for Pb, and the lifetime of the tube was approximately 400 firings. The limits of detection (LOD) based on integrated absorbance (0.03 μg l -1 for Cd, 0.8 μg l -1 for Pb) exceeded the requirements of Brazilian Food Regulations (decree #55871 from Health Department), which establish the maximum permissible level for Cd at 200 μg l -1 and for Pb at 500 μg l -1. The relative standard deviations ( n=12) were typically <8% for Cd and <6% for Pb. The recoveries of Cd and Pb added to wine samples varied from 88 to 107% and 93 to 103%, respectively. The accuracy of the direct determination of Cd and Pb was checked for 10 table wines by comparing the results with those obtained for digested wine using single-element ET-AAS, which were in agreement at the 95% confidence level.

  17. Quantification of the fluorine containing drug 5-fluorouracil in cancer cells by GaF molecular absorption via high-resolution continuum source molecular absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Krüger, Magnus; Huang, Mao-Dong; Becker-Roß, Helmut; Florek, Stefan; Ott, Ingo; Gust, Ronald

    The development of high-resolution continuum source molecular absorption spectrometry made the quantification of fluorine feasible by measuring the molecular absorption as gallium monofluoride (GaF). Using this new technique, we developed on the example of 5-fluorouracil (5-FU) a graphite furnace method to quantify fluorine in organic molecules. The effect of 5-FU on the generation of the diatomic GaF molecule was investigated. The experimental conditions such as gallium nitrate amount, temperature program, interfering anions (represented as corresponding acids) and calibration for the determination of 5-FU in standard solution and in cellular matrix samples were investigated and optimized. The sample matrix showed no effect on the sensitivity of GaF molecular absorption. A simple calibration curve using an inorganic sodium fluoride solution can conveniently be used for the calibration. The described method is sensitive and the achievable limit of detection is 0.23 ng of 5-FU. In order to establish the concept of "fluorine as a probe in medicinal chemistry" an exemplary application was selected, in which the developed method was successfully demonstrated by performing cellular uptake studies of the 5-FU in human colon carcinoma cells.

  18. Flame and graphite furnace atomic absorption spectrometry for trace element determination in vegetable oils, margarine and butter after sample emulsification.

    PubMed

    Ieggli, C V S; Bohrer, D; Do Nascimento, P C; De Carvalho, L M

    2011-05-01

    Trace element analysis plays an important role in oil characterisation and in the detection of oil adulteration because the quality of edible oils and fats is affected by their trace metal content. In this study, the quantification of selected metals in various oils and fats (rice oil, canola oil, sunflower oil, corn oil, soy oil, olive oil, light margarine, regular margarine and butter) was carried out using flame atomic absorption spectrometry (FAAS) and graphite furnace atomic absorption spectrometry (GFAAS) after sample emulsification. FAAS was used to determine the Na, K, Ca, Mg, Zn and Fe levels in the samples, while GFAAS was used for quantifying Cr, Ni, As, Pb, Cd, Cu and Mn, as these elements appeared in the samples at much lower concentrations. Tween-80 and Triton X-100 were employed as surfactants, and emulsions were prepared by a conventional method that involved heating and mixing of the constituents. Complete stabilisation was achieved through magnetic stirring for 15 min at room temperature. The evaluated figures of merit were linearity, accuracy and sensitivity, which were determined by the characteristic concentration and mass. Analysis of spiked samples demonstrated accuracy, which ranged from 90% (Na) to 112% (Fe) for FAAS and from 83% (Cd) to 121% (Pb) for GFAAS measurements. Atomic absorption spectrometry proved to be a promising approach for the analysis of metals in emulsified edible oils and fats. Additionally, under appropriate emulsification conditions (formulation, stirring time and temperature), the emulsions were homogeneous, had excellent stability, and had appropriate viscosity. The proposed method has proved to be simple, sensitive, reproducible, and economical.

  19. Determination of lithium isotopes at natural abundance levels by atomic absorption spectrometry

    USGS Publications Warehouse

    Meier, A.L.

    1982-01-01

    The relationships of the absorption of 6Li and 7Li hollow cathode lamp emissions are used to determine lithium isotopic composition in the natural abundance range of geologic materials. Absorption was found to have a nonlinear dependence upon total lithium concentration and isotopic composition. A method using nonlinear equations to describe the relationship of the absorption of 6Li and 7Li lamp radiation is proposed as a means of calculating isotopic composition that is independent of total lithium concentration.

  20. La pulvérisation par ultra-sons appliquée à la spectrometrie d'absorption atomique.

    PubMed

    Spitz, J; Uny, G

    1968-07-01

    Ultrasonic nebulization applied to atomic absorption spectrometry gives a sensitivity ten to twenty times better than that which can be obtained by classical pneumatic nebulization. This gain in sensitivity is primarily due to the quantity of aerosol introduced into the flame, but is equally due to the fineness of the droplets that are formed. The study of certain parameters (frequency, power applied to the emitter, geometry of the nebulizing chamber, gas flow) has led to the specification of an ultrasonic nebulizer that can be conveniently used for routine analyses.

  1. Determination of cadmium and lead in edible oils by electrothermal atomic absorption spectrometry after reverse dispersive liquid-liquid microextraction.

    PubMed

    López-García, Ignacio; Vicente-Martínez, Yesica; Hernández-Córdoba, Manuel

    2014-06-01

    The dispersive liquid-liquid microextraction of edible oils with a low volume of an acidic solution in the presence of isopropyl alcohol allows cadmium and lead to be completely separated into the aqueous phase. After centrifugation, the metals are determined by electrothermal atomization atomic absorption spectrometry using a palladium salt for chemical modification in the heating cycle. Using a 10 g oil sample, the enrichment factor is 140, which permits detection limits of 0.6 and 10 ng kg(-1) for cadmium and lead, respectively. The results agree with those obtained after sample mineralization. Data for the cadmium and lead levels for 15 samples of different characteristics are given.

  2. Determination of gold in geologic materials by solvent extraction and atomic-absorption spectrometry

    USGS Publications Warehouse

    Huffman, Claude; Mensik, J.D.; Riley, L.B.

    1967-01-01

    The two methods presented for the determination of traces of gold in geologic materials are the cyanide atomic-absorption method and the fire-assay atomic-absorption method. In the cyanide method gold is leached with a sodium-cyanide solution. The monovalent gold is then oxidized to the trivalent state and concentrated by extracting into methyl isobutyl ketone prior to estimation by atomic absorption. In the fire-assay atomic-absorption method, the gold-silver bead obtained from fire assay is dissolved in nitric and hydrochloric acids. Gold is then concentrated by extracting into methyl isobutyl ketone prior to determination by atomic absorption. By either method concentrations as low as 50 parts per billion of gold can be determined in a 15-gram sample.

  3. Arsenic in marine tissues — The challenging problems to electrothermal and hydride generation atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Karadjova, Irina B.; Petrov, Panayot K.; Serafimovski, Ivan; Stafilov, Trajče; Tsalev, Dimiter L.

    2007-03-01

    Analytical problems in determination of arsenic in marine tissues are addressed. Procedures for the determination of total As in solubilized or extracted tissues with tetramethylammonium hydroxide and methanol have been elaborated. Several typical lyophilized tissues were used: NIST SRM 1566a 'Oyster Tissue', BCR-60 CRM 'Trace Elements in an Aquatic Plant ( Lagarosiphon major)', BCR-627 'Forms of As in Tuna Fish Tissue', IAEA-140/TM 'Sea Plant Homogenate', NRCC DOLT-1 'Dogfish Liver' and two representatives of the Black Sea biota, Mediterranean mussel ( Mytilus galloprovincialis) and Brown algae ( Cystoseira barbata). Tissues (nominal 0.3 g) were extracted in tetramethylammonium hydroxide (TMAH) 1 ml of 25% m/v TMAH and 2 ml of water) or 5 ml of aqueous 80% v/v methanol (MeOH) in closed vessels in a microwave oven at 50 °C for 30 min. Arsenic in solubilized or extracted tissues was determined by electrothermal atomic absorption spectrometry (ETAAS) after appropriate dilution (nominally to 25 ml, with further dilution as required) under optimal instrumental parameters (pyrolysis temperature 900 °C and atomization temperature 2100 °C) with 1.5 μg Pd as modifier on Zr-Ir treated platform. Platforms have been pre-treated with 2.7 μmol of zirconium and then with 0.10 μmol of iridium which served as a permanent chemical modifier in direct ETAAS measurements and as an efficient hydride sequestration medium in flow injection hydride generation (FI-HG)-ETAAS. TMAH and methanol extract 96-108% and 51-100% of As from CRMs. Various calibration approaches have been considered and critically evaluated. The effect of species-dependent slope of calibration graph or standard additions plot for total As determination in a sample comprising of several individual As species with different ETAAS behavior has been considered as a kind of 'intrinsic element speciation interference' that cannot be completely overcome by standard additions technique. Calibration by means of CRMs has

  4. Determination of cadmium and lead in urine by derivative flame atomic absorption spectrometry using the atom trapping technique

    NASA Astrophysics Data System (ADS)

    Han-wen, Sun; De-qiang, Zhang; Li-li, Yang; Jian-min, Sun

    1997-06-01

    A method is described for the determinations of cadmium and lead in urine by derivative flame atomic absorption spectrometry with a modified water-cooled stainless steel atom trapping tube. The effects of the trap position, the flame conditions, the coolant flow rates, and the collection time were studied. With a 1 min collection time, the characteristic concentrations (derivative absorbance of 0.0044) for cadmium and lead were 0.028 and 1.4 μg L -1, the detection limits (3σ) were 0.02 and 0.27 μg L -1, respectively. The detection limits and sensitivities of the proposed method were 2 and 3 orders of magnitude higher for 1-3 min collection time than those of conventional flame atomic absorption spectrometry for cadmium and lead, respectively. Urine samples from a small population of normal individuals have been analyzed for cadmium and lead by the proposed method. Satisfactory recoveries of 91-110% and 91-106%, for Cd and Pb were obtained with these urine samples.

  5. Contents of cadmium, mercury and lead in fish from the Atlantic sea (Morocco) determined by atomic absorption spectrometry.

    PubMed

    Chahid, Adil; Hilali, Mustapha; Benlhachimi, Abdeljalil; Bouzid, Taoufiq

    2014-03-15

    As a part of a specific monitoring program, lead (Pb) cadmium (Cd) and mercury (Hg) concentrations in important species of fish from various fishing ports of the southern Kingdom of Morocco (Sardina pilchardus, Scomber scombrus, Plectorhinchus mediterraneus, Trachurus trachurus, Octopus vulgaris, Boops boops, Sarda sarda, Trisopterus capelanus, and Conger conger) were investigated by the Moroccan Reference Laboratory (NRL) for trace elements in foodstuffs of animal origin. The samples were analysed for lead and cadmium by a graphite furnace atomic absorption spectrometry (GFAAS); and for mercury by cold vapour atomic absorption spectrometry (CVAAS). The results were expressed as μg/g of wet weight (w/w). The levels of Cd, Pb and Hg in muscles of fish were 0.009-0.036, 0.013-0.114 and 0.049-0.194 μg/g, respectively. The present study showed that different metals were present in the sample at different levels but within the maximum residual levels prescribed by the EU for the fish and shellfish from these areas, in general, should cause no health problems for consumers.

  6. Determination of some trace elements in food and soil samples by atomic absorption spectrometry after coprecipitation with holmium hydroxide.

    PubMed

    Saracoglu, Sibel; Soylak, Mustafa; Cabuk, Dilek; Topalak, Zeynep; Karagozlu, Yasemin

    2012-01-01

    The determination of trace elements in food and soil samples by atomic absorption spectrometry was investigated. A coprecipitation procedure with holmium hydroxide was used for separation-preconcentration of trace elements. Trace amounts of copper(II), manganese(II), cobalt(II), nickel(ll), chromium(lll), iron(Ill), cadmium(ll), and lead(ll) ions were coprecipitated with holmium hydroxide in 2.0 M NaOH medium. The optimum conditions for the coprecipitation process were investigated for several commonly tested experimental parameters, such as amount of coprecipitant, effect of standing time, centrifugation rate and time, and sample volume. The precision, based on replicate analysis, was lower than 10% for the analytes. In order to verify the accuracy of the method, the certified reference materials BCR 141 R calcareous loam soil and CRM 025-050 soil were analyzed. The procedure was successfully applied for separation and preconcentration of the investigated ions in various food and soil samples. An amount of the solid samples was decomposed with 15 mL concentrated hydrochloric acid-concentrated nitric acid (3 + 1). The preconcentration procedure was then applied to the final solutions. The concentration of trace elements in samples was determined by atomic absorption spectrometry.

  7. Determination of Chlorine in Milk via Molecular Absorption of SrCl Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry.

    PubMed

    Ozbek, Nil; Akman, Suleyman

    2016-07-20

    Total chlorine in milk was determined via the molecular absorption of diatomic strontium monochloride at 635.862 nm using high-resolution continuum source graphite furnace atomic absorption spectrometry. The effects of coating the graphite furnace, using different modifiers, amount of molecule-forming element, and different calibrants were investigated and optimized. Chlorine concentrations in milk samples were determined in a Zr-coated graphite furnace using 25 μg of Sr as the molecule-forming reagent and applying a pyrolysis temperature of 600 °C and a molecule-forming temperature of 2300 °C. Linearity was maintained up to 500 μg mL(-1) of Cl. The method was tested by analyzing a certified reference wastewater. The results were in the uncertainty limits of the certified value. The limit of detection of the method was 1.76 μg mL(-1). The chlorine concentrations in various cow milk samples taken from the market were found in the range of 588-1472 mg L(-1).

  8. Separation and preconcentration of chromium species by selective absorption on Lemna minor and determination by slurry atomisation electrothermal atomic absorption spectrometry.

    PubMed

    Zhu, G; Li, S

    2001-08-01

    A novel method for the separation and preconcentration of Cr(III)/Cr(VI) with Lemna minor and determination by slurry atomization electrothermal atomic absorption spectrometry (ETAAS) was developed. A sample solution was added to a polyethylene beaker containing 10 mg of 160 mesh pre-treated Lemna minor, adjusted to pH 1.0, stirred for 8 min for selective absorption of Cr(III) and then centrifuged. The upper layer of solution was transferred into another polyethylene beaker containing 10 mg of 160 mesh pre-treated Lemna minor, adjusted to pH 5.0, stirred for 12 min for adsorption of the residual Cr(VI) and centrifuged. The two residues in two centrifuge tubes were washed twice with water, 2 ml of agar solution added, stirred for 2 min, then two slurries were prepared and used for the determination of Cr(III) and Cr(VI) by ETAAS. Detection limits (3sigma) of 0.01 microg L(-1) for Cr(III) and 0.03 microg L(-1) for Cr(VI) were obtained. The relative standard deviation was 2.8% for Cr(III) and 3.3% for Cr(VI) at the 1 microg L(-1) level. The method was applied to the determination of Cr(III)/Cr(VI) in water samples. The analytical recoveries of Cr(III) and Cr(VI) added to samples were 97-102 and 96-103%, respectively.

  9. Electrothermal atomization atomic absorption spectrometry for the determination of lead in urine: results of an interlaboratory study

    NASA Astrophysics Data System (ADS)

    Parsons, Patrick J.; Slavin, Walter

    1999-05-01

    Results of an interlaboratory study are reported for the determination of lead in urine. Two levels of a lyophilized material containing biologically-bound lead were prepared using pooled urine obtained from lead-poisoned children undergoing the CaNa 2EDTA mobilization test. The materials were circulated to a group of reference laboratories that participate in the `New York State Proficiency Testing Program for Blood Lead'. Results of the initial round-robin gave all-method consensus target values of 145±22 μg/l (S.D.) for lot 17 and 449±43 μg/l (S.D.) for lot 20. The interlaboratory exercise was repeated some 5 years later and consensus target values were re-calculated using the grand mean (excluding outliers) of results reported by laboratories using electrothermal atomization atomic absorption spectrometry (ETAAS). The re-calculated target values were 139±10 μg/l (S.D.) and 433±12 μg/l (S.D.). The urine reference materials were also analyzed for lead by several laboratories using other instrumental techniques including isotope dilution (ID), inductively coupled plasma (ICP) mass spectrometry (MS), flame atomic absorption with extraction, ICP-atomic emission spectrometry, ID-gas chromatography MS and flow injection-hydride generation AAS, thus providing a rich source of analytical data with which to characterize them. The materials were also used in a long-term validation study of an ETAAS method developed originally for blood lead determinations that has since been used unmodified for the determination of lead in urine also. Recently, urine lead method performance has been tracked in a proficiency testing program specifically for this analysis. In addition, a number of commercial control materials have been analyzed and evaluated.

  10. Chromium determination in pharmaceutical grade barium sulfate by solid sampling electrothermal atomic absorption spectrometry with Zeeman-effect background correction.

    PubMed

    Bolzan, Rodrigo Cordeiro; Rodrigues, Luis Frederico; Mattos, Júlio Cezar Paz de; Dressler, Valderi Luiz; Flores, Erico Marlon de Moraes

    2007-11-15

    A procedure for chromium (Cr) determination in pharmaceutical grade barium sulfate by direct solid sampling electrothermal atomic absorption spectrometry (DSS-ET AAS) with Zeeman-effect background correction was developed. Operational conditions for the proposed procedure and the use of citric acid, ammonium phosphate, palladium and magnesium nitrate as chemical modifiers were evaluated. Pyrolysis and atomization temperatures were set at 1500 and 2400 degrees C, respectively and the use of matrix modifiers did not improve these conditions. Graphite platform presented high degradation rate, but minima changes were observed in the sensitivity or signal profile. Samples (0.3-1 mg) were weighted and introduced into the furnace using a manual solid sampling system. The linear concentration range of the calibration curve was from 100 to 1800 pg (R(2)>0.995). The characteristic mass was 7.7 pg and the limit of detection was 2.4 pg. Chromium concentration in commercial samples ranged from 0.45 to 1.06 microg g(-1) and these results were confirmed by standard addition method. The mean reproducibility was 12% (n=20 in a 3-day period) and repeatability was less than 9%. Results obtained using inductively coupled plasma optical emission spectrometry and conventional electrothermal atomic absorption spectrometry after extraction with HNO3 were around 20% lower than those obtained by the proposed procedure. It was assumed that the low results were due to incomplete extraction even using hard conditions related to temperature and pressure. The proposed procedure by DSS-ET AAS provided some advantages related to recommended pharmacopoeias methodology, as lower risks of contamination and analyte losses, higher specificity, accuracy and sensitivity, no toxic or unstable reagents are required, and calibration with aqueous standards was feasible.

  11. Fluorine determination in coal using high-resolution graphite furnace molecular absorption spectrometry and direct solid sample analysis

    NASA Astrophysics Data System (ADS)

    Machado, Patrícia M.; Morés, Silvane; Pereira, Éderson R.; Welz, Bernhard; Carasek, Eduardo; de Andrade, Jailson B.

    2015-03-01

    The absorption of the calcium mono-fluoride (CaF) molecule has been employed in this study for the determination of fluorine in coal using direct solid sample analysis and high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS). The rotational line at 606.440 nm was used for measuring the molecular absorption in the gas phase. The pyrolysis and vaporization temperatures were 700 °C and 2100 °C, respectively. Different chemical modifiers have been studied, such as Pd and Ir as permanent modifiers, and Pd and the mixed Pd/Mg modifier in solution. The limit of detection and the characteristic mass were 0.3 and 0.1 ng F, respectively. One certified reference material (CRM) of coal (NIST 1635) and four CRMs with a non-certified value for F (SARM 18, SARM 20, BCR 40, BCR 180) were used to evaluate the accuracy and precision of the method, obtaining good agreement (104%) with the certified value and with the informed values (ranging from 90 to 103%).

  12. High resolution Fourier transform spectrometry in emission and absorption in the visible and UV ranges

    NASA Astrophysics Data System (ADS)

    Luc, Paul

    1995-07-01

    This paper gives the main results obtained at Laboratoire Aimé Cotton, using Fourier transform spectroscopy (FTS) in the visible and UV ranges. After a rapid historical survey, a description of the fourth generation interferometer, which is specially designed to record visible and UV light will be given. Typical results in emission and absorption spectroscopy, including the metrological applications, will follow.

  13. Role of a binary metallic modifier in the determination of cadmium in graphite furnace atomic absorption spectrometry.

    PubMed

    Morimoto, Syun; Ashino, Tetsuya; Wagatsuma, Kazuaki

    2010-01-01

    In order to discuss the matrix modifier effect of palladium, iron, and a mixture of palladium and iron for the determination of cadmium in graphite-furnace atomic absorption spectrometry (GF-AAS), we measured the absorption profiles of a cadmium line at various compositions of these elements. Variations in the gas temperature were also estimated with the progress of atomization, by using a two-line method under the assumption of a Boltzmann distribution. The atomic absorption of cadmium appeared on the way of heating from the charring temperature to the atomizing temperature while the gas temperature was still low; it was thus considered that cadmium was atomized through direct conductive heating from the wall of the graphite furnace. Therefore, the effectiveness of modifiers for cadmium would be determined through any reactions on the furnace wall at the programmed charring and atomizing temperatures. The addition of iron, palladium, and an iron-palladium mixture all enhanced the absorption signal of cadmium compared to a pure cadmium sample; however, their effects were different from one another. Each addition of iron or palladium to the sample solution led to an enhancement of the cadmium absorbance, indicating that iron or palladium individually became an effective matrix modifier for the determination of cadmium. However, the addition of palladium was ineffective for the matrix modification in the coexistence of large amounts of iron. Although these phenomena are very complicated, and thus cannot be understood completely, any metallurgical reaction between the constituent elements during heating of the furnace wall, such as the formation of solid solutions and intermetallic compounds, would cause the effect of a matrix modifier in GF-AAS.

  14. Mercury speciation in hair by headspace injection-gas chromatography-atomic fluorescence spectrometry (methylmercury) and combustion-atomic absorption spectrometry (total Hg).

    PubMed

    Gao, Y; De Galan, S; De Brauwere, A; Baeyens, W; Leermakers, M

    2010-10-15

    The speciation of Hg in human hair was carried out with combustion-atomic absorption spectrometry for total Hg (THg) and headspace-gas chromatography-atomic fluorescence spectrometry (HS-GC-AFS) for methylmercury (MMHg). The determination of total Hg in hair was carried out with the AMA analyzer (Advanced Mercury Analyser 254). Accuracy and reproducibility were assessed on a Certified Reference hair sample (IAEA-086 CRM), yielding, respectively, a recovery of 97.5% and a RSD of 3.2%. Analyses of 10 blank measurements resulted in a detection limit of 1.5 ng g(-1) of THg for a 20mg sample of human hair. MMHg concentrations in hair were assessed with HS-GC-AFS in a single analysis step. Either acid or alkaline extraction can be applied because they yielded very similar results on a IAEA-086 CRM: we observed a recovery of 103% and a RSD of 7% with acid extraction and a recovery of 110% and a RSD of 9% with alkaline extraction. Optimization of the headspace vial, injection and GC parameters is described. The detection limit of the MMHg determination in human hair, which amounts to 0.04 ng g(-1) for a 20mg sample, is far below the concentrations observed in natural samples. The number of samples that can be analyzed per hour, respectively, amounts to 8 for THg and 4 for MMHg. Finally, Hg speciation in natural human hair samples was carried out by combining both AMA and HS-GC-AFS analysis methods. THg levels were at the μg g(-1), level, with an average MMHg fraction of about 70%.

  15. Temporal and spatial temperature distributions in transversely heated graphite tube atomizers and their analytical characteristics for atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Sperling, Michael; Welz, Bernard; Hertzberg, Joachim; Rieck, Christof; Marowsky, Gerd

    1996-07-01

    The important role which temperature plays in atomic absorption spectrometry (AAS) for the formation and detection of atoms in the absorption volume is discussed and the literature is reviewed. Non-homogeneous temperature distribution in the absorption volume is in contradiction to one of the prerequisites for the application of Beer's law used in AAS to convert absorbance into analyte concentration or mass, and is particularly troublesome for an "absolute analysis" envisaged for electrothermal atomic absorption spectrometry (ETAAS). Coherent anti-Stokes Raman scattering (CARS) is used to study the gas-phase temperature distribution in a state-of-the-art transversely heated graphite tube atomizer (THGA). The effect of the internal gas flow on the size of the heated atmosphere is studied by steady-state temperature measurements. Temporally and spatially resolved measurements make it possible to study the temperature field within the atomizer volume in all three dimensions during the rapid heating of the furnace to final temperatures in the range 2173-2673 K. The role of the integrated platform of the THGA on the temperature field is investigated by temperature measurements of the gas phase in the presence and absence of the platform. The platform is identified as the major source of temperature gradients inside the tube volume, which may be as high as 1000 K in the radial direction during rapid heating. These gradients are most pronounced for heating cycles starting at room temperature and gradually decrease with increasing starting temperature. Shortly after the tube wall reaches its final temperature, the gas-phase temperature equilibrates and approaches the wall temperature. Because of the unavoidable contact with the cold environment at the open ends of the tube, minor temperature gradients are observed in the gas phase also in longitudinal direction, which can be further reduced by restricting the openings with end caps. The results obtained for the THGA are

  16. The application of solid sorbents for the purification of aluminum contaminated chemicals used as modifiers in electrothermal atomic absorption spectrometry.

    PubMed

    Bulska, E; Pyrzyńska, K

    1996-06-01

    Various microcolumns with solid sorbents (ion exchange resins, functionalised cellulose sorbents, chelating resins) have been tested with respect to their ability for the purification of aluminum contaminated chemicals used as modifiers in electrothermal atomic absorption spectrometry. The purification of NaNO(3), Mg(NO(3))(2), K(2)SO(4) and (NH(4))(2)HPO(4) has been the most effective with an almost 100% efficiency, when Spheron-Oxine was used as chelating resin. The sorption of aluminum from KOH solution has been found to be very high (around 90%) for all investigated sorbents. However, the best results have been obtained with anion-exchange resins. It has been difficult to purify concentrated mineral acids (HCl, H(2)SO(4)). A retention of aluminum above 80% has been achieved only when Cellex P, Chelex 100 or Amberlite XAD-2 have been used.

  17. Determination of total mercury in environmental and biological samples by flow injection cold vapour atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Murphy, James; Jones, Phil; Hill, Steve J.

    1996-12-01

    A simple and accurate method has been developed for the determination of total mercury in environmental and biological samples. The method utilises an off-line microwave digestion stage followed by analysis using a flow injection system with detection by cold vapour atomic absorption spectrometry. The method has been validated using two certified reference materials (DORM-1 dogfish and MESS-2 estuarine sediment) and the results agreed well with the certified values. A detection limit of 0.2 ng g -1 Hg was obtained and no significant interference was observed. The method was finally applied to the determination of mercury in river sediments and canned tuna fish, and gave results in the range 0.1-3.0 mg kg -1.

  18. Determination of occupational exposure to organotin compounds after multivariate optimization of a liquid chromatography flame atomic absorption spectrometry system

    NASA Astrophysics Data System (ADS)

    Nygren, Olle

    1993-07-01

    The detection limit, obtained with a previously developed liquid chromatography flame atomic absorption spectrometry system, was not low enough for the determination of occupational exposure to organotin compounds. Optimization of the system was thus necessary. Many experimental factors may influence the response of the system, and interaction effects between these parameters may also be expected. With optimization by multivariate methods, the response of the system was improved and a 2.5-times better detection limit for organotin compounds was obtained, which was adequate for determination of occupational exposure. The system was employed for determination of occupational exposure to organotin-based wood preservatives at an impregnation plant. No exposure to butyltin compounds above 1/10 of the threshold limit value could be measured at any sampling place. It was also found that up to 30% of the tributyltin in impregnation solutions in use was dealkylated to less fungitoxic dibutyltin compounds, which may affect the quality of the impregnation.

  19. Diagnostics of reactive pulsed plasmas by UV and VUV absorption spectroscopy and by modulated beam Mass spectrometry

    NASA Astrophysics Data System (ADS)

    Cunge, Gilles

    2011-10-01

    Pulsed plasmas are promising for etching applications in the microelectronic industry. However, many new phenomena are involved when a high density discharge is pulsed. To better understand these processes it is necessary to probe the radicals' kinetics with a microsecond resolution. We have developed several diagnostics to reach this goal including broad band absorption spectroscopy with UV LEDs to detect small polyatomic radicals and with a deuterium VUV source to detect larger closed shell molecules and the modulated mass spectrometry to monitor atomic species. We will discuss the impact of the plasma pulsing frequency and duty cycle on the radical densities in Cl2 based plasmas, and the consequences on plasma processes. Work done in collaboration with Paul Bodart, Melisa Brihoum, Maxime Darnon, Erwin Pargon, Olivier Joubert, and Nader Sadeghi, CNRS/LTM.

  20. Determination of arsenic, antimony, bismuth, cadmium, copper, lead, molybdenum, silver and zinc in geological materials by atomic-absorption spectrometry

    USGS Publications Warehouse

    Viets, J.G.; O'Leary, R. M.; Clark, Robert J.

    1984-01-01

    Arsenic, antimony, bismuth, cadmium, copper, lead, molybdenum, silver and zinc are very useful elements in geochemical exploration. In the proposed method, geological samples are fused with potassium pyrosulphate and the fusate is dissolved in a solution of hydrochloric acid, ascorbic acid and potassium iodide. When this solution is shaken with a 10% V/V Aliquat 336 - isobutyl methyl ketone organic phase, the nine elements of interest are selectively partitioned in the organic phase. All nine elements can then be determined in the organic phase using flame atomic-absorption spectrometry. The method is rapid and allows the determination of Ag and Cd at levels down to 0.1 p.p.m., Cu, Mo, and Zn down to 0.5 p.p.m., Pb, Bi and Sb down to 1 p.p.m. and As down to 5 p.p.m. in geological materials.

  1. Impact of the analytical blank in the uncertainty evaluation of the copper content in waters by flame atomic absorption spectrometry.

    PubMed

    de Oliveira, Elcio Cruz; Monteiro, Maria Inês Couto; Pontes, Fernanda Veronesi Marinho; de Almeida, Marcelo Dominguez; Carneiro, Manuel Castro; da Silva, Lílian Irene Dias; Alcover Neto, Arnaldo

    2012-01-01

    Chemical analysts use analytical blanks in their analyses, but seldom is this source of uncertainty evaluated. Generally, there is great confusion. Although the numerical value of the blank, in some situations, can be negligible, its source of uncertainty cannot be. This article discusses the uncertainty contribution of the analytical blank using a numerical example of the copper content in waters by flame atomic absorption spectrometry. The results indicate that the uncertainties of the analytical blank can contribute up to 50% when the blank sample is considered in this analysis, confirming its high impact. This effect can be primarily observed where the analyte concentration approaches the lower range of the analytical curve. Even so, the blank is not always computed. Therefore, the relevance of the analytical blank can be confirmed by uncertainty evaluation.

  2. Determination of bismuth in environmental samples by slurry sampling graphite furnace atomic absorption spectrometry using combined chemical modifiers.

    PubMed

    Dobrowolski, Ryszard; Dobrzyńska, Joanna; Gawrońska, Barbara

    2015-01-01

    Slurry sampling graphite furnace atomic absorption spectrometry technique was applied for the determination of Bi in environmental samples. The study focused on the effect of Zr, Ti, Nb and W carbides, as permanent modifiers, on the Bi signal. Because of its highest thermal and chemical stability and ability to substantially increase Bi signal, NbC was chosen as the most effective modifier. The temperature programme applied for Bi determination was optimized based on the pyrolysis and atomization curves obtained for slurries prepared from certified reference materials (CRMs) of the soil and sediments. To overcome interferences caused by sulfur compounds, Ba(NO₃)₂ was used as a chemical modifier. Calibration was performed using the aqueous standard solutions. The analysis of the CRMs confirmed the reliability of the proposed analytical method. The characteristic mass for Bi was determined to be 16 pg with the detection limit of 50 ng/g for the optimized procedure at the 5% (w/v) slurry concentration.

  3. Determination of silver, bismuth, cadmium, copper, lead, and zinc in geologic materials by atomic absorption spectrometry with tricaprylylmethylammonium chloride

    USGS Publications Warehouse

    Viets, J.G.

    1978-01-01

    Interferences commonly encountered in the determination of silver, bismuth, cadmium, copper, lead, and zinc at crustal abundance levels are effectively eliminated using a rapid, sensitive, organic extraction technique. A potassium chlorate-hydrochloric acid digestion solubilizes the metals not tightly bound in the silicate lattice of rocks, soils, and stream sediments. The six metals are selectively extracted into a 10% Aliquat 336-MIBK organic phase in the presence of ascorbic acid and potassium iodide. Metals in the organic extract are determined by flame atomic absorption spectrometry to the 0.02-ppm level for silver, cadmium, copper, and zinc and to the 0.2-ppm level for bismuth and lead with a maximum relative standard deviation of 18.8% for known reference samples. An additional hydrofluoric acid digestion may be used to determine metals substituted in the silicate lattice.

  4. Determination of chromium, manganese and vanadium in sediments and soils by modifier—free slurry sampling electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Mierzwa, J.; Sun, Yuh-Chang; Yang, Mo-Hsiung

    1998-01-01

    Slurried sediment and soil samples of the certified reference materials with a highly elevated level of the metals of interest (Mn, Cr and V) were analysed by electrothermal atomic absorption spectrometry (ETAAS) with Zeeman effect background correction. The method of slurry preparation and time-temperature programmes were optimized and, finally, the use of chemical modifiers was not necessary. The effect of alternate spectral lines and gas mini-flows on characteristic masses of analytes was studied. The homogeneity of samples and the influence of short sample grinding were also discussed. The simple, aqueous standard based calibration graphs (except Mn at the concentration > 1000 mg kg -1) were applied for the quantification of results. The results of determinations obtained by slurry sampling agreed well with the cetified values, and the relative standard deviations (RSDs) for the over-all analytical procedure repeatability (at slurries concentration level about 2 mg/2 ml) were less than 9.5%, except manganese (10.4%).

  5. A new approach to mineralization of flaxseed (Linum usitatissimum L.) for trace element analysis by flame atomic absorption spectrometry.

    PubMed

    Oliveira, João P S; Silva, Francisco L F; Monte, Raimundo J G; Matos, Wladiana O; Lopes, Gisele S

    2017-06-01

    A new approach to the analysis of Cu, Fe, Mn and Zn in flaxseed was developed based on infrared-assisted acid digestion. Quantitation by flame atomic absorption spectrometry yields results in agreement with those arising from aggressive total decomposition using conventional microwave-assisted (MW) digestions. A full factorial design in two levels was applied to evaluate the impact of significant variables for all elements to determine optimal experimental conditions. A desirability function revealed these to be: 2.0g sample mass, 8mL of HNO3 and 8min of heating time in the IR system. Precision better than 10% (RSD) was obtained, superior to that of a combined IR-MW approach. Sample preparation based on IR-assisted digestion provides a rapid and inexpensive alternative to other conventional techniques for the analysis of complex samples and is able to accommodate relatively large masses of sample, alleviating potential homogeneity issues as well as enhancing detection power.

  6. Determination of cadmium by electrothermal atomic absorption spectrometry after microwave-assisted digestion of animal tissues and sewage sludges.

    PubMed

    Chakraborty, R; Das, A K; Cervera, M L; De La Guardia, M

    1996-04-01

    The determination of cadmium in different sample types has been carried out by electrothermal atomization atomic absorption spectrometry with D(2)-background correction using a unpyrocoated graphite tube, after pressurized microwave-assisted digestion. Five chemical modifiers [(NH(4))(2)HPO(4), Pd(NO)(3))(2), Ni(NO(3))(2), thiourea and Triton X-100] have been assayed and nickel nitrate has been found to be most effective for an accurate determination of cadmium in mussel tissue, pig kidney and sewage sludge. The characteristic mass of the method is of the order of 1 pg and the limit of detection is lower than 0.1 ng/ml.

  7. Simultaneous preconcentration of cadmium and lead in water samples with silica gel and determination by flame atomic absorption spectrometry.

    PubMed

    Xu, Hongbo; Wu, Yun; Wang, Jian; Shang, Xuewei; Jiang, Xiaojun

    2013-12-01

    A new method that utilizes pretreated silica gel as an adsorbent has been developed for simultaneous preconcentration of trace Cd(II) and Pb(II) prior to the measurement by flame atomic absorption spectrometry. The effects of pH, the shaking time, the elution condition and the coexisting ions on the separation/preconcentration conditions of analytes were investigated. Under optimized conditions, the static adsorption capacity of Cd(II) and Pb(II) were 45.5 and 27.1mg/g, the relative standard deviations were 3.2% and 1.7% (for n = 11), and the limits of detection obtained were 4.25 and 0.60 ng/mL, respectively. The method was validated by analyzing the certified reference materials GBW 07304a (stream sediment) and successfully applied to the analysis of various treated wastewater samples with satisfactory results.

  8. Determination of cadmium in spring water by graphite-furnace atomic absorption spectrometry after coprecipitation with ytterbium hydroxide.

    PubMed

    Atsumi, Kousuke; Minami, Tomoharu; Ueda, Joichi

    2005-06-01

    A coprecipitation method with ytterbium hydroxide was studied for the determination of cadmium in water samples by graphite-furnace atomic absorption spectrometry. Up to 40 ng of cadmium in water samples was quantitatively coprecipitated with ytterbium hydroxide at pH 8.0-11.2. The concentration factor was 100 fold. The coprecipitated cadmium was sensitively determined without any influence of ytterbium and the calibration curve was linear from 0.1 to 4 ng/mL of cadmium. The detection limit (signal/noise = 2) was 2.9 pg/mL in 100 mL of the initial sample solution. Twenty-nine diverse ions tested did not interfere with the determination in at least a 10000-fold mass ratio to cadmium. The proposed method was successfully applied to the determination of cadmium in spring water.

  9. Determination of cobalt in biological samples by line-source and high-resolution continuum source graphite furnace atomic absorption spectrometry using solid sampling or alkaline treatment

    NASA Astrophysics Data System (ADS)

    Ribeiro, Anderson Schwingel; Vieira, Mariana Antunes; da Silva, Alessandra Furtado; Borges, Daniel L. Gallindo; Welz, Bernhard; Heitmann, Uwe; Curtius, Adilson José

    2005-06-01

    Two procedures for the determination of Co in biological samples by graphite furnace atomic absorption spectrometry (GF AAS) were compared: solid sampling (SS) and alkaline treatment with tetramethylammonium hydroxide (TMAH) using two different instruments for the investigation: a conventional line-source (LS) atomic absorption spectrometer and a prototype high-resolution continuum source atomic absorption spectrometer. For the direct introduction of the solid samples, certified reference materials (CRM) were ground to a particle size ≤50 μm. Alkaline treatment was carried out by placing about 250 mg of the sample in polypropylene flasks, adding 2 mL of 25% m/v tetramethylammonium hydroxide and de-ionized water. Due to its unique capacity of providing a 3-D spectral plot, a high-resolution continuum source (HR-CS) graphite furnace atomic absorption spectrometry was used as a tool to evaluate potential spectral interferences, including background absorption for both sample introduction procedures, revealing that a continuous background preceded the atomic signal for pyrolysis temperatures lower than 700 °C. Molecular absorption bands with pronounced rotational fine structure appeared for atomization temperatures >1800 °C probably as a consequence of the formation of PO. After optimization had been carried out using high resolution continuum source atomic absorption spectrometry, the optimized conditions were adopted also for line-source atomic absorption spectrometry. Six biological certified reference materials were analyzed, with calibration against aqueous standards, resulting in agreement with the certified values (according to the t-test for a 95% confidence level) and in detection limits as low as 5 ng g -1.

  10. Determination of boron in silicon-doped gallium arsenide by electrothermal atomic absorption spectrometry and ultraviolet-visible spectrophotometry.

    PubMed

    Taddia, Marco; Cerroni, Maria Grazia; Morelli, Elio; Musiani, Andrea

    2002-01-01

    Two methods have been developed for the determination of boron impurities in silicon-doped gallium arsenide (GaAs) for electronics. The first method employs the electrothermal atomic absorption spectrometry (ETAAS), the second, the UV-Vis molecular absorption spectrophotomety. In both cases the GaAs sample is decomposed with aqua regia (1+1). To prevent Ga(III) interference on the ETAAS determination of boron, a double extraction of the chlorogallic acid (HGaCl4) in diethyl ether is performed. To improve the overall ETAAS performance, the graphite tubes were pre-treated with iridium(III) and tungsten(IV). A mixed chemical modifier containing Ni(II), Sr(II) and citric acid was also used. The characteristic mass (m0) is 301 +/- 47 pg and the detection limit (3sB) is 2.4 microg g(-1). The classic UV-Vis spectrophotometric procedure using curcumin was also extended to the determination of boron in GaAs. By masking Ga(III) with EDTA and a preliminary extraction of boron with 2-ethyl-hexane 1,3-diol, performed on a semi-micro scale, a detection limit of 0.6 microg g(-1) was achieved. Both methods were applied to the analysis of two Si-doped GaAs samples which were suspected of being boron-contaminated. Results are compared with those obtained by direct analysis of the decomposed sample solution using the inductively coupled plasma atomic emission spectrometry (ICP-AES).

  11. Direct determination of Cu, Mn, Pb, and Zn in beer by thermospray flame furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Nascentes, Clésia C.; Kamogawa, Marcos Y.; Fernandes, Kelly G.; Arruda, Marco A. Z.; Nogueira, Ana Rita A.; Nóbrega, Joaquim A.

    2005-06-01

    In this work, thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was employed for Cu, Mn, Pb, and Zn determination in beer without any sample digestion. The system was optimized and calibration was based on the analyte addition technique. A sample volume of 300 μl was introduced into the hot Ni tube at a flow-rate of 0.4 ml min -1 using 0.14 mol l -1 nitric acid solution or air as carrier. Different Brazilian beers were directly analyzed after ultrasonic degasification. Results were compared with those obtained by graphite furnace atomic absorption spectrometry (GFAAS). The detection limits obtained for Cu, Mn, Pb, and Zn in aqueous solution were 2.2, 18, 1.6, and 0.9 μg l -1, respectively. The relative standard deviations varied from 2.7% to 7.3% ( n=8) for solutions containing the analytes in the 25-50 μg l -1 range. The concentration ranges obtained for analytes in beer samples were: Cu: 38.0-155 μg l -1; Mn: 110-348 μg l -1, Pb: 13.0-32.9 μg l -1, and Zn: 52.7-226 μg l -1. Results obtained by TS-FF-AAS and GFAAS were in agreement at a 95% confidence level. The proposed method is fast and simple, since sample digestion is not required and sensitivity can be improved without using expensive devices. The TS-FF-AAS presented suitable sensitivity for determination of Cu, Mn, Pb, and Zn in the quality control of a brewery.

  12. Fast sequential determination of antimony and lead in pewter alloys using high-resolution continuum source flame atomic absorption spectrometry.

    PubMed

    Dessuy, Morgana B; de Jesus, Robson M; Brandao, Geovani C; Ferreira, Sergio L C; Vale, Maria Goreti R; Welz, Bernhard

    2013-01-01

    A simple method has been developed to determine antimony and lead in pewter alloy cups produced in Brazil, using fast sequential determination by high-resolution continuum source flame atomic absorption spectrometry. The samples were dissolved in HCl and H(2)O(2), employing a cold finger system in order to avoid analyte losses. The main resonance line of lead at 217.001 nm and a secondary line of antimony at 212.739 nm were used. The limits of detection for lead and antimony were 0.02 and 5.7 mg L(-1), respectively. The trueness of the method was established by recovery tests and comparing the results obtained by the proposed method with those obtained by inductively coupled plasma optical emission spectrometry. The results were compared using a student's t-test and there was no significant difference at a 95% confidence interval. With the developed methods, it was possible to determine accurately antimony and lead in pewter samples. The lead concentration found in the analysed samples was around 1 mg g(-1), which means that they are not lead free; however, the content was below the maximum allowed level of 5 mg g(-1). The antimony content, which was found to be between 40 and 46 mg g(-1), is actually of greater concern, as antimony is known to be potentially toxic already at very low concentrations, although there is no legislation yet for this element.

  13. [Determination of trace silver in water samples by solid phase extraction portable tungsten-coil electrothermal atomic absorption spectrometry].

    PubMed

    Fan, Guang-yu; Jiang, Xiao-ming; Zheng, Cheng-bin; Hou, Xian-deng; Xu, Kai-lai

    2011-07-01

    A simple method has been developed for the determination of silver in environmental water samples using solid phase extraction with tungsten-coil electrothermal atomic absorption spectrometry. Silica gel was used as an adsorbent and packed into a syringe barrel for solid phase extraction of silver prior to its determination by using a portable tungsten-coil electrothermal atomic absorption spectrometer. Optimum conditions for adsorption and desorption of silver ion, as well as interferences from co-existing ions, were investigated. A sample pH value of 6.0, a sample loading flow rate of 4.0 mL x min(-1), and the mixture of 4% (m/v) thiourea and 2% (phi) nitrate acid with the eluent flow rate of 0.5 mL x min(-1) for desorption were selected for further studies. Under optimal conditions, a linear range of 0.20-4.00 ng x mL(-1), a limit of detection (3sigma) of 0.03 ng x mL(-1) and a preconcentration factor of 94 were achieved. The proposed method was validated by testing three environmental water samples with satisfactory results.

  14. Determination of trace concentrations of chlorine in aqueous solutions by high-resolution continuum source graphite furnace molecular absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Machyňák, Ľubomír; Čacho, František; Němeček, Martin; Beinrohr, Ernest

    2016-11-01

    Trace concentrations of total chlorine were determined by means of molecular absorption of indium mono-chloride (InCl) at 267.217 nm using high-resolution continuum source graphite furnace molecular absorption spectrometry. The effects of chemical modifiers and the amount of In on the sensitivity and accuracy were investigated. The optimum pyrolysis and vaporization temperatures were 600 °C and 1400 °C, respectively. The limit of detection and characteristic mass were found to be 0.10 ng and 0.21 ng, respectively. Potential non-spectral and spectral interferences were tested for various metals and non-metals at concentrations up to 50 mg L- 1 and for phosphoric, sulphuric and nitric acids. No spectral interferences were observed. Significant non-spectral interferences were observed with F, Br, and I at concentrations higher than 1 mg L- 1, 5 mg L- 1 and 25 mg L- 1, respectively, which is probably caused by formation of competitive indium halogen molecules. Higher concentrations of mineral acids depressed the signal owing to the formation of volatile HCl. The calibration curve was linear in the range between 0.3 and 10 ng with a correlation coefficient of R = 0.993. The elaborated method was used for the chlorine determination in various waters and a drug sample.

  15. Determination of mercury in an assortment of dietary supplements using an inexpensive combustion atomic absorption spectrometry technique.

    PubMed

    Levine, Keith E; Levine, Michael A; Weber, Frank X; Hu, Ye; Perlmutter, Jason; Grohse, Peter M

    2005-01-01

    The concentrations of mercury in forty, commercially available dietary supplements, were determined using a new, inexpensive analysis technique. The method involves thermal decomposition, amalgamation, and detection of mercury by atomic absorption spectrometry with an analysis time of approximately six minutes per sample. The primary cost savings from this approach is that labor-intensive sample digestion is not required prior to analysis, further automating the analytical procedure. As a result, manufacturers and regulatory agencies concerned with monitoring lot-to-lot product quality may find this approach an attractive alternative to the more classical acid-decomposition, cold vapor atomic absorption methodology. Dietary supplement samples analyzed included astragalus, calcium, chromium picolinate, echinacea, ephedra, fish oil, ginger, ginkgo biloba, ginseng, goldenseal, guggul, senna, St John's wort, and yohimbe products. Quality control samples analyzed with the dietary supplements indicated a high level of method accuracy and precision. Ten replicate preparations of a standard reference material (NIST 1573a, tomato leaves) were analyzed, and the average mercury recovery was 109% (2.0% RSD). The method quantitation limit was 0.3 ng, which corresponded to 1.5 ng/g sample. The highest found mercury concentration (123 ng/g) was measured in a concentrated salmon oil sample. When taken as directed by an adult, this product would result in an approximate mercury ingestion of 7 mug per week.

  16. Determination of Mercury in an Assortment of Dietary Supplements Using an Inexpensive Combustion Atomic Absorption Spectrometry Technique

    PubMed Central

    Levine, Michael A.; Weber, Frank X.; Hu, Ye; Perlmutter, Jason; Grohse, Peter M.

    2005-01-01

    The concentrations of mercury in forty, commercially available dietary supplements, were determined using a new, inexpensive analysis technique. The method involves thermal decomposition, amalgamation, and detection of mercury by atomic absorption spectrometry with an analysis time of approximately six minutes per sample. The primary cost savings from this approach is that labor-intensive sample digestion is not required prior to analysis, further automating the analytical procedure. As a result, manufacturers and regulatory agencies concerned with monitoring lot-to-lot product quality may find this approach an attractive alternative to the more classical acid-decomposition, cold vapor atomic absorption methodology. Dietary supplement samples analyzed included astragalus, calcium, chromium picolinate, echinacea, ephedra, fish oil, ginger, ginkgo biloba, ginseng, goldenseal, guggul, senna, St John's wort, and yohimbe products. Quality control samples analyzed with the dietary supplements indicated a high level of method accuracy and precision. Ten replicate preparations of a standard reference material (NIST 1573a, tomato leaves) were analyzed, and the average mercury recovery was 109% (2.0% RSD). The method quantitation limit was 0.3 ng, which corresponded to 1.5 ng/g sample. The highest found mercury concentration (123 ng/g) was measured in a concentrated salmon oil sample. When taken as directed by an adult, this product would result in an approximate mercury ingestion of 7 μg per week. PMID:18924735

  17. A simple indirect automatic method to determine total iodine in milk products by flame atomic absorption spectrometry.

    PubMed

    Yebra, M C; Bollaín, M H

    2010-07-15

    A simple, precise and accurate automatic method for the determination of total iodine in milk products by indirect atomic absorption spectrometry is proposed. Iodide in solutions resulting from alkaline ashing of samples is precipitated with silver ion in a precipitation-dissolution flow manifold, which allows performing on-line the retention of the silver iodide precipitate formed on a filter, its wash with diluted ammonia and its dissolution with a diluted thiosulfate solution. Dissolved silver is also determined on-line by flame atomic absorption, and the achieved amount of this metal is proportional to that of iodine in the sample. The proposed method is very selective, avoids interferences from anions present in the samples, which can be also precipitated with silver, because these silver compounds are dissolved with ammonia at the washing step. This method allows the determination of iodine in the range 0.011-0.35 microg mL(-1) with a relative standard deviation between 1.3 and 6.8% at a rate of ca. 17 samplesh(-1).

  18. Atomic Absorption Spectroscopy, Atomic Emission Spectroscopy, and Inductively Coupled Plasma-Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Miller, Dennis D.; Rutzke, Michael A.

    Atomic spectroscopy has played a major role in the development of our current database for mineral nutrients and toxicants in foods. When atomic absorption spectrometers became widely available in the 1960s, the development of atomic absorption spectroscopy (AAS) methods for accurately measuring trace amounts of mineral elements in biological samples paved the way for unprecedented advances in fields as diverse as food analysis, nutrition, biochemistry, and toxicology (1). The application of plasmas as excitation sources for atomic emission spectroscopy (AES) led to the commercial availability of instruments for inductively coupled plasma - atomic emission spectroscopy (ICP-AES) beginning in the late 1970s. This instrument has further enhanced our ability to measure the mineral composition of foods and other materials rapidly, accurately, and precisely. More recently, plasmas have been joined with mass spectrometers (MS) to form inductively coupled plasma-mass spectrometer ICP-MS instruments that are capable of measuring mineral elements with extremely low detection limits. These three instrumental methods have largely replaced traditional wet chemistry methods for mineral analysis of foods, although traditional methods for calcium, chloride, iron, and phosphorus remain in use today (see Chap. 12).

  19. Determination of sodium and potassium in nanoliter volumes of biological fluids by furnace atomic absorption spectrometry

    SciTech Connect

    Nash, L.A.; Peterson, L.N.; Nadler, S.P.; Levine, D.Z.

    1988-11-01

    Renal tubular fluid samples are nanoliter (10/sup -9/ L) volumes containing sodium and potassium concentrations that are within the range of determination by furnace atomic absorption. Modification of nanoliter handling techniques and the use of microboats with the IL 951/655 provided a method for rapid precise analyses (relative standard deviation of 5%). Determinations of sodium and potassium were precise; however, inaccuracies occurred with anion substitution of sodium salts. NaHCO/sub 3/ solutions gave consistently higher peak height absorbance and area absorbance compared with those of NaCl: the peak area absorbance correlated linearly with the concentration of bicarbonate. Pretreatment of the microboat with boric acid eliminated this phenomenon and the associated inaccuracy. Comparison of determination of sodium in nanoliter samples by graphite furnace atomic absorption with macroanalysis by flame emission gave relative errors of less than 2.0%. Addition of sodium and potassium to tubular fluid samples yielded mean recoveries of 102.6% and 99.7%, respectively. The authors conclude that graphite furnace can be an accurate method for measurement of sodium and potassium in nanoliter volumes of biological fluids.

  20. Multi-element analysis of manganese nodules by atomic absorption spectrometry without chemical separation

    USGS Publications Warehouse

    Kane, J.S.; Harnly, J.M.

    1982-01-01

    Five manganese nodules, including the USGS reference nodules A-1 and P-1, were analyzed for Co, Cu, Fe, K, Mg, Mn, Na, Ni and Zn without prior chemical separation by using a simultaneous multi-element atomic absorption spectrometer with an air-cetylene flame. The nodules were prepared in three digestion matrices. One of these solutions was measured using sixteen different combinations of burner height and air/acetylene ratios. Results for A-1 and P-1 are compared to recommended values and results for all nodules are compared to those obtained with an inductively coupled plasma. The elements Co, Cu, Fe, K, Mg, Mn, Na, Ni, and Zn are simultaneously determined with a composite recovery for all elements of 100 ?? 7%, independent of the digestion matrices, heights in the flame, or flame stoichiometries examined. Individual recoveries for Co, K, and Ni are considerably poorer in two digests than this composite figure, however. The optimum individual recoveries of 100 ?? 5% and imprecisions of 1-4%, except for zinc, are obtained when Co, K, Mn, Na and Ni are determined simultaneously in a concentrated digest, and in another analytical sequence, when Cu, Fe, Mg, Mn and Zn are measured simultaneously after dilution. Determination of manganese is equally accurate in the two sequences; its measurement in both assures internal consistency between the two measurement sequences. This approach improves analytical efficiency over that for conventional atomic absorption methods, while minimizing loss of accuracy or precision for individual elements. ?? 1982.

  1. Determination of sulphur in various vegetables by solid sampling high-resolution electrothermal molecular absorption spectrometry.

    PubMed

    Gunduz, Sema; Akman, Suleyman

    2015-04-01

    Sulphur was determined in various vegetables via molecular absorption of carbon monosulphide (CS) at 258.056 nm using a solid sampling high resolution continuum source electrothermal atomic absorption spectrometer (SS HR-CS ETAAS). Samples were dried, ground and directly introduced into the ruthenium coated graphite furnace as 0.05 to 0.50mg. All determinations were performed using palladium+citric acid modifier and applying a pyrolysis temperature of 1000 °C and a volatilisation temperature of 2400 °C. The results were in good agreement with certified sulphur concentrations of various vegetal CRM samples applying linear calibration technique prepared from thioacetamide. The limit of detection and characteristic mass of the method were 7.5 and 8.7 ng of S, respectively. The concentrations of S in various spinach, leek, lettuce, radish, Brussels sprouts, zucchini and chard samples were determined. It was showed that distribution of sulphur in CRM and grinded food samples were homogeneous even in micro-scale.

  2. Determination of trace amounts of tin in geological materials by atomic absorption spectrometry

    USGS Publications Warehouse

    Welsch, E.P.; Chao, T.T.

    1976-01-01

    An atomic absorption method is described for the determination of traces of tin in rocks, soils, and stream sediments. A dried mixture of the sample and ammonium iodide is heated to volatilize tin tetraiodide -which is then dissolved in 5 % hydrochloric acid, extracted into TOPO-MIBK, and aspirated into a nitrous oxide-acetylene flame. The limit of determination is 2 p.p.m. tin and the relative standard deviation ranges from 2 to 14 %. Up to 20 % iron and 1000 p.p.m. Cu, Pb, Zn, Mn, Hg, Mo, V, or W in the sample do not interfere. As many as 50 samples can be easily analyzed per man-day. ?? 1976.

  3. Determination of tributyltin in tissues and sediments by graphite furnace atomic absorption spectrometry

    SciTech Connect

    Stephenson, M.D.; Smith, D.R.

    1988-04-01

    A method for the determination of tributyltin (TBT) in tissue and sediments has been developed for environmental samples. The technique involves extraction with methylene chloride and isolation of TBT from mono- and dibutyltin with a sodium hydroxide wash. The TBT is then back extracted and converted to elemental Sn with nitric acid. Analysis is by Zeeman graphite furnace atomic absorption spectrophotometry. Recoveries of spiked samples were between 99% and 111% for mussel and fish tissues and 72% and 99% for various sediments. The limit of quantification was 0.0025 ..mu..g/g for tissue (on a wet weight basis). This technique was developed in response to their need to process large numbers of environmental samples with a minimum time investment.

  4. Determination of thallium in wine by electrothermal atomic absorption spectrometry after extraction preconcentration

    NASA Astrophysics Data System (ADS)

    Cvetković, Julijana; Arpadjan, Sonja; Karadjova, Irina; Stafilov, Trajče

    2002-06-01

    A simple method for extraction electrothermal atomic absorption spectroscopy (ETAAS) determination of Tl in wine is described. The wine sample is decomposed with a mixture of nitric acid and hydrogen peroxide and both thallium species Tl(I) and Tl(III) are extracted from 0.5 mol l -1 KI solution into iso-butyl methyl ketone (IBMK). Optimal parameters for ETAAS measurement of the iodide complexes extracted were defined for two different instruments: Perkin Elmer Zeeman 3030 (HGA 600) and Varian SpectrAA-880 (GTA-100). Modifiers of tartaric acid, Pd [ammoniumtetrachloropaladate (II)] or Ag (silver nitrate) were investigated for thermal stabilization of such extremely volatile species as iodide complexes of Tl. The analytical procedure developed permits 50-fold preconcentration and determination of 0.05 μg l -1 Tl in wine. The relative standard deviation ranges from 6 to 12% for the concentration range 0.2-1 μg l -1 Tl in wine.

  5. Comparison of different sample preparation methods for platinum determination in cultured cells by graphite furnace atomic absorption spectrometry

    PubMed Central

    Cai, Jing; Jia, Jinghui; Zhang, Yuzeng; Dong, Weihong

    2017-01-01

    Background Platinum-based agents are widely used in chemotherapy against solid tumors and insufficient intracellular drug accumulation is one of the leading causes of platinum resistance which is associated with poor survival of tumor patients. Thus, the detection of intracellular platinum is pivotal for studies aiming to overcome platinum resistance. In the present study, we aimed to establish a reliable graphite furnace atomic absorption spectrometry (GFAAS)-based assay to quantify the intracellular platinum content for cultured cells. Methods Several most commonly applied cell preparation methods, including 0.2% HNO3, 0.2% Triton X-100, concentrated nitric acid, RIPA combined with concentrated nitric acid and hydroxide, followed by GFAAS for platinum detection were compared in ovarian, cervical and liver cancer cell lines to obtain the optimal one, and parameters regarding linearity, accuracy, precision and sensitivity were evaluated. Influence of other metals on platinum detection and the storage conditions of samples were also determined. Results The treatment of cells with 0.2% HNO3 was superior to other approaches with fewer platinum loss and better repeatability. The recovery rate and precision of this method were 97.3%–103.0% and 1.4%–3.8%, respectively. The average recoveries in the presence of other metals were 95.1%–103.1%. The detection limit was 13.23 ug/L. The recovery rate of platinum remained acceptable even in cell samples stored in −20 °C or −80 °C for two months. Discussion After comparison, we found that 0.2% HNO3 was optimal for intracellular platinum quantification based on GFAAS, which presented values compatible with that of inductively-coupled plasma mass-spectrometry (ICP-MS), and this is partially attributed to the simplicity of this method. Moreover, the assay was proved to be accurate, sensitive, cost-effective and suitable for the research of platinum-based antitumor therapy. PMID:28123908

  6. Germanium determination by flame atomic absorption spectrometry: an increased vapor pressure-chloride generation system.

    PubMed

    Kaya, Murat; Volkan, Mürvet

    2011-03-15

    A new chloride generation system was designed for the direct, sensitive, rapid and accurate determination of the total germanium in complex matrices. It was aimed to improve the detection limit of chloride generation technique by increasing the vapor pressure of germanium tetrachloride (GeCl(4)). In order to do so, a novel joint vapor production and gas-liquid separation unit equipped with a home-made oven was incorporated to an ordinary nitrous oxide-acetylene flame atomic absorption spectrometer. Several variables such as reaction time, temperature and acid concentration have been investigated. The linear range for germanium determination was 0.1-10 ng mL(-1) for 1 mL sampling volume with a detection limit (3s) of 0.01 ng mL(-1). The relative standard deviation (RSD) was 2.4% for nine replicates of a 1 ng mL(-1) germanium solution. The method was validated by the analysis of one non-certified and two certified geochemical reference materials, respectively, CRM GSJ-JR-2 (Rhyolite), and GSJ-JR-1 (Rhyolite), and GBW 07107 (Chinese Rock). Selectivity of the method was investigated for Cd(2+), Co(2+), Cu(2+), Fe(3+), Ga(3+), Hg(2+), Ni(2+), Pb(2+), Sn(2+), and Zn(2+) ions and ionic species of As(III), Sb(III), Te(IV), and Se(IV).

  7. Determination of fluorine in milk samples via calcium-monofluoride by electrothermal molecular absorption spectrometry.

    PubMed

    Ozbek, Nil; Akman, Suleyman

    2013-05-01

    The determination of fluorine in milk samples via the molecular absorption of calcium mono-fluoride (CaF) was performed using a HR-CS-ETAAS. For this purpose, calcium was pipetted to graphite furnace together with samples. The amount of Ca and the graphite furnace program were optimised. Fluorine was determined in pyrolytically coated platforms at 606.440 nm applying a pyrolysis temperature of 700 °C and a molecule forming temperature of 2250 °C. Finally, applying standard addition technique, F contents of several milk samples were determined. The results obtained by linear calibration and standard addition techniques were significantly different which can be attributed to non-spectral interferences in milk due to matrix concomitants. Therefore, in order to tolerate the errors, the F contents of several milk samples were determined applying standard addition technique. However, since the ingredients of milk samples change for different kinds, the F in each sample was determined from its own standard addition curve. The range of F content for the milk samples were 0.027-0.543 μg mL(-1). The limit of detection and characteristic mass of the method were 0.26 and 0.13 ng of F, respectively.

  8. Determination of mercury(II) ion by electrochemical cold vapor generation atomic absorption spectrometry.

    PubMed

    Arbab-Zavar, M Hosein; Rounaghi, G Hosein; Chamsaz, Mahmoud; Masrournia, Mahboube

    2003-05-01

    A technique for determination of mercury is described; it is based on electrolytic reduction of Hg(II) ion on a graphite cathode, the trapping of mercury vapor and its volatilization into a quartz tube aligned in the optical path of an atomic absorption spectrometer. The electrochemical cell consisted of a graphite cathode and an anode operating with constant direct current for the production of mercury atoms. A pre-activated graphite rod was used as the cathode material. The optimum conditions for electrochemical generation of mercury cold vapor (the electrolysis time and current, the flow rate, the type of electrode and electrolyte) were investigated. The characteristic electrochemical data with chemical cold vapor using NaBH4-acid were compared. The presence of cadmium(II), arsenic(III), antimony(III), selenium(IV), bismuth(III), silver(I), lead(II), lithium(I), sodium(I) and potassium(I) showed interference effects which were eliminated by suitable separation techniques. The calibration curve is linear over the range of 5-90 ng ml(-1) mercury(II). The detection limit is 2 ng ml(-1) of Hg(II) and the RSD is 2.5% (n = 10) for 40 ng ml(-1). The accuracy and recovery of the method were investigated by analyzing spiked tap water and river water.

  9. Slurry sampling graphite furnace atomic absorption spectrometry: determination of trace metals in mineral coal.

    PubMed

    Silva, M M; Goreti, M; Vale, R; Caramão, E B

    1999-12-06

    A procedure for lead, cadmium and copper determination in coal samples based on slurry sampling using an atomic absorption spectrometer equipped with a transversely heated graphite tube atomizer is proposed. The slurries were prepared by weighing the samples directly into autosampler cups (5-30 mg) and adding a 1.5 ml aliquot of a diluent mixture of 5% v/v HNO(3), 0.05% Triton X-100 and 10% ethanol. The slurry was homogenized by manual stirring before measurement. Slurry homogenization using ultrasonic agitation was also investigated for comparison. The effect of particle size and the use of different diluent compositions on the slurry preparation were investigated. The temperature programmes were optimized on the basis of pyrolysis and atomization curves. Absorbance characteristics with and without the addition of a palladium-magnesium modifier were compared. The use of 0.05% m/v Pd and 0.03% m/v Mg was found satisfactory for stabilizing Cd and Pb. The calibration was performed with aqueous standards. In addition, a conventional acid digestion procedure was applied to verify the efficiency of the slurry sampling. Better recoveries of the analytes were obtained when the particle size was reduced to <37 mum. Several certified coal reference materials (BCR Nos. 40, 180, and 181) were analyzed, and good agreement was obtained between the results from the proposed slurry sampling method and the certificate values.

  10. Determination of total tin in silicate rocks by graphite furnace atomic absorption spectrometry

    USGS Publications Warehouse

    Elsheimer, H.N.; Fries, T.L.

    1990-01-01

    A method is described for the determination of total tin in silicate rocks utilizing a graphite furnace atomic absorption spectrometer with a stabilized-temperature platform furnace and Zeeman-effect background correction. The sample is decomposed by lithium metaborate fusion (3 + 1) in graphite crucibles with the melt being dissolved in 7.5% hydrochloric acid. Tin extractions (4 + 1 or 8 + 1) are executed on portions of the acid solutions using a 4% solution of tricotylphosphine oxide in methyl isobutyl ketone (MIBK). Ascorbic acid is added as a reducing agent prior to extraction. A solution of diammonium hydrogenphosphate and magnesium nitrate is used as a matrix modifier in the graphite furnace determination. The limit of detection is > 10 pg, equivalent to > 1 ??g l-1 of tin in the MIBK solution or 0.2-0.3 ??g g-61 in the rock. The concentration range is linear between 2.5 and 500 ??g l-1 tin in solution. The precision, measured as relative standard deviation, is < 20% at the 2.5 ??g l-1 level and < 7% at the 10-30 ??g l-1 level of tin. Excellent agreement with recommended literature values was found when the method was applied to the international silicate rock standards BCR-1, PCC-1, GSP-1, AGV-1, STM-1, JGb-1 and Mica-Fe. Application was made to the determination of tin in geological core samples with total tin concentrations of the order of 1 ??g g-1 or less.

  11. Human Vitamin B12 Absorption and Metabolism are Measured by Accelerator Mass Spectrometry Using Specifically Labeled 14C-Cobalamin

    SciTech Connect

    Carkeet, C; Dueker, S R; Lango, J; Buchholz, B A; Miller, J W; Green, R; Hammock, B D; Roth, J R; Anderson, P J

    2006-01-26

    There is need for an improved test of human ability to assimilate dietary vitamin B{sub 12}. Assaying and understanding absorption and uptake of B{sub 12} is important because defects can lead to hematological and neurological complications. Accelerator mass spectrometry (AMS) is uniquely suited for assessing absorption and kinetics of {sup 14}C-labeled substances after oral ingestion because it is more sensitive than decay counting and can measure levels of carbon-14 ({sup 14}C) in microliter volumes of biological samples, with negligible exposure of subjects to radioactivity. The test we describe employs amounts of B{sub 12} in the range of normal dietary intake. The B{sub 12} used was quantitatively labeled with {sup 14}C at one particular atom of the DMB moiety by exploiting idiosyncrasies of Salmonellametabolism. In order to grow aerobically on ethanolamine, S. entericamust be provided with either pre-formed B{sub 12} or two of its precursors: cobinamide and dimethylbenzimidazole (DMB). When provided with {sup 14}C-DMB specifically labeled in the C2 position, cells produced {sup 14}C-B{sub 12} of high specific activity (2.1 GBq/mmol, 58 mCi/mmol) and no detectable dilution of label from endogenous DMB synthesis. In a human kinetic study, a physiological dose (1.5 mg, 2.2 KBq/59 nCi) of purified {sup 14}C-B{sub 12} was administered and showed plasma appearance and clearance curves consistent with the predicted behavior of the pure vitamin. This method opens new avenues for study of B{sub 12} assimilation.

  12. Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry.

    PubMed

    da Silva, Alessandra Furtado; Borges, Daniel L G; Lepri, Fábio Grandis; Welz, Bernhard; Curtius, Adilson J; Heitmann, Uwe

    2005-08-01

    This work describes the development of a method to determine cadmium in coal, in which iridium is used as a permanent chemical modifier and calibration is performed against aqueous standards by high-resolution continuum source atomic absorption spectrometry (HR-CS AAS). This new instrumental concept makes the whole spectral environment in the vicinity of the analytical line accessible, providing a lot more data than just the change in absorbance over time available from conventional instruments. The application of Ir (400 microg) as a permanent chemical modifier, thermally deposited on the pyrolytic graphite platform surface, allowed pyrolysis temperatures of 700 degrees C to be used, which was sufficiently high to significantly reduce the continuous background that occurred before the analyte signal at pyrolysis temperatures <700 degrees C. Structured background absorption also occurred after the analyte signal when atomization temperatures of >1600 degrees C were used, which arose from the electron-excitation spectrum (with rotational fine structure) of a diatomic molecule. Under optimized conditions (pyrolysis at 700 degrees C and atomization at 1500 degrees C), interference-free determination of cadmium in seven certified coal reference materials and two real samples was achieved by direct solid sampling and calibrating against aqueous standards, resulting in good agreement with the certified values (where available) at the 95% confidence level. A characteristic mass of 0.4 pg and a detection limit of 2 ng g(-1), calculated for a sample mass of 1.0 mg coal, was obtained. A precision (expressed as the relative standard deviation, RSD) of <10% was typically obtained when coal samples in the mass range 0.6-1.2 mg were analyzed.

  13. Determination of selected elements in whole coal and in coal ash from the eight argonne premium coal samples by atomic absorption spectrometry, atomic emission spectrometry, and ion-selective electrode

    USGS Publications Warehouse

    Doughten, M.W.; Gillison, J.R.

    1990-01-01

    Methods for the determination of 24 elements in whole coal and coal ash by inductively coupled argon plasma-atomic emission spectrometry, flame, graphite furnace, and cold vapor atomic absorption spectrometry, and by ion-selective electrode are described. Coal ashes were analyzed in triplicate to determine the precision of the methods. Results of the analyses of NBS Standard Reference Materials 1633, 1633a, 1632a, and 1635 are reported. Accuracy of the methods is determined by comparison of the analysis of standard reference materials to their certified values as well as other values in the literature.

  14. Determination of trace amounts of molybdenum in plant tissue by solvent extraction-atomic-absorption and direct-current plasma emission spectrometry.

    PubMed

    Lajunen, L H; Kubin, A

    1986-03-01

    Methods are presented for determination of molybdenum in plant tissue by flame and graphite-furnace atomic-absorption spectrometry and direct-current argon-plasma emission spectrometry. The samples are digested in HNO(3)-H(2)SO(4)-HC1O(4) mixture, and Mo is separated and concentrated by chelation and extraction. Three organic solvents (methyl isobutyl ketone, di-isobutyl ketone and isoamyl alcohol) and two ligands (8-hydroxyquinoline and toluene-3,4-dithiol) were studied. The procedure were tested on pine needle and birch leaf samples.

  15. Determination of trace amounts of zinc by flame atomic absorption spectrometry after preconcentration with modified clinoptilolite zeolite.

    PubMed

    Hajialigol, Saeed; Taher, Mohammad Ali; Malekpour, Akbar

    2008-01-01

    Natural clinoptilolite was used as a sorbent material for solid-phase extraction and preconcentration of zinc. Clinoptilolite was first saturated with cadmium (II) and then modified with benzyldimethyltetradecylammonium chloride for increasing adsorption of 3-(2-arsenophenylazo)-4,5-dihydroxy-2,7-naphthalene disulfonic acid (neothorin). Zinc was quantitatively retained on the adsorbent by the column method in the pH range of 3.8-4.2 at a flow rate of 1 mL/min. It was eluted from the column with 5.0 mL 2 M nitric acid solution at a flow rate of 1 mL/min and determined by flame atomic absorption spectrometry at 213.9 nm. Zinc could be concentrated from a 0.03 microg/L solution with a preconcentration factor of 170. Relative standard deviation for 8 replicate determinations of 2.5 microg zinc in the final solution was 0.92%. The interference of a large number of anions and cations was studied in detail to optimize the conditions, and the method was successfully applied for determination of zinc in standard and real water samples.

  16. Calcium in the developing Ambystoma neural axis shown by 3H and fluorescent chlortetracycline and atomic absorption spectrometry

    SciTech Connect

    Moran, D.J. )

    1990-12-01

    The calcium ion has been implicated in the mediation of the morphogenetic movements that occur during neural tube formation. The present study identifies high levels of calcium in the neuroepithelium of the neural plate, folds, and tube. These levels are substantially higher than those discerned elsewhere in the embryo. The calcium is localized in morphogenetically active regions by using the antibiotic chlortetracycline (CTC) which chelates calcium and is demonstrated in this investigation by both autoradiography and calcium-linked fluorescence. The specificity of CTC reaction for calcium in the developing neural axis is confirmed by EGTA competition. A comparison of the actual calcium levels in the developing neural axis (dorsal) with equivalently weighted ventral tissues was obtained by atomic absorption spectrometry (AAS). This method provides a total count of the calcium without any loss during tissue processing. For AAS, living tissues were precisely excised and immediately dessicated. Each tissue sample (dry weight 1.5 mg) was then solubilized for analysis. The spectrometric data reveal that the embryonic dorsal aspect forming the neural tube contains 57% more calcium than an equivalent weight of the ventral aspect.

  17. Detection of silver nanoparticles in parsley by solid sampling high-resolution-continuum source atomic absorption spectrometry.

    PubMed

    Feichtmeier, Nadine S; Leopold, Kerstin

    2014-06-01

    In this work, we present a fast and simple approach for detection of silver nanoparticles (AgNPs) in biological material (parsley) by solid sampling high-resolution-continuum source atomic absorption spectrometry (HR-CS AAS). A novel evaluation strategy was developed in order to distinguish AgNPs from ionic silver and for sizing of AgNPs. For this purpose, atomisation delay was introduced as significant indication of AgNPs, whereas atomisation rates allow distinction of 20-, 60-, and 80-nm AgNPs. Atomisation delays were found to be higher for samples containing silver ions than for samples containing silver nanoparticles. A maximum difference in atomisation delay normalised by the sample weight of 6.27 ± 0.96 s mg(-1) was obtained after optimisation of the furnace program of the AAS. For this purpose, a multivariate experimental design was used varying atomisation temperature, atomisation heating rate and pyrolysis temperature. Atomisation rates were calculated as the slope of the first inflection point of the absorbance signals and correlated with the size of the AgNPs in the biological sample. Hence, solid sampling HR-CS AAS was proved to be a promising tool for identifying and distinguishing silver nanoparticles from ionic silver directly in solid biological samples.

  18. Selective speciation of inorganic antimony on tetraethylenepentamine bonded silica gel column and its determination by graphite furnace atomic absorption spectrometry.

    PubMed

    Mendil, Durali; Bardak, Hilmi; Tuzen, Mustafa; Soylak, Mustafa

    2013-03-30

    A speciation system for antimony (III) and antimony (V) ions that based on solid phase extraction on tetraethylenepentamine bonded silica gel has been established. Antimony was determined by graphite furnace atomic absorption spectrometry (GF-AAS). Analytical conditions including pH, sample volume, etc., were studied for the quantitative recoveries of Sb (III) and Sb (V). Matrix effects on the recovery were also investigated. The recovery values and detection limit for antimony (III) at optimal conditions were found as >95% and 0.020 μg L(-1), respectively. Preconcentration factor was calculated as 50. The capacity of adsorption for the tetraethylenepentamine bonded silica gel was 7.9 mg g(-1). The validation was checked by analysis of NIST SRM 1573a Tomato laves and GBW 07605 Tea certified reference materials. The procedure was successfully applied to speciation of antimony in tap water, mineral water and spring water samples. Total antimony was determined in refined salt, unrefined salt, black tea, rice, tuna fish and soil samples after microwave digestion and presented enrichment method combination.

  19. Evaluation of arsenic, cobalt, copper and manganese in biological Samples of Steel mill workers by electrothermal atomic absorption Spectrometry.

    PubMed

    Afridi, H I; Kazi, T G; Kazi, N G; Jamali, M K; Arain, M B; Sirajuddin; Kandhro, G A; Shah, A Q; Baig, J A

    2009-02-01

    The determination of trace and toxic elements in biological samples (blood, urine and scalp hair samples) of human beings is an important clinical test. The aim of our present study was to determine the concentration of arsenic (As), copper (Cu), cobalt (Co) and manganese (Mn), in biological samples of male production workers (PW) and quality control workers (QW) of steel mill, with aged 25-55 years, to assess the possible influence of environmental exposure. For comparison purpose, the same biological samples of unexposed healthy males of same age group were collected as control subjects. The determination of all elements in biological samples was carried out by electrothermal atomic absorption spectrometry, prior to microwave assisted acid digestion. The accuracy of the As, Cu, Co and Mn measurements was tested by simultaneously analyzing certified reference materials (CRMs) and for comparative purposes conventional wet acid digestion method was used on the same CRMs. No significant differences were observed between the analytical results and the certified values, using both methods (paired t-test at P > 0.05). The results indicate that concentrations of As, Cu, Co and Mn in all three biological samples of the exposed workers (QW and PW) were significantly higher than those of the controls. The possible correlation of these elements with the etiology of different physiological disorders is discussed. The results were also demonstrated the need of attention for improvements in workplace, ventilation and industrial hygiene practices.

  20. Cloud point extraction for the determination of copper, nickel and cobalt ions in environmental samples by flame atomic absorption spectrometry.

    PubMed

    Ghaedi, M; Shokrollahi, A; Ahmadi, F; Rajabi, H R; Soylak, M

    2008-02-11

    A cloud point extraction procedure was presented for the preconcentration of copper, nickel and cobalt ions in various samples. After complexation with methyl-2-pyridylketone oxime (MPKO) in basic medium, analyte ions are quantitatively extracted to the phase rich in Triton X-114 following centrifugation. 1.0 mol L(-1) HNO(3) nitric acid in methanol was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). The adopted concentrations for MPKO, Triton X-114 and HNO(3), bath temperature, centrifuge rate and time were optimized. Detection limits (3 SDb/m) of 1.6, 2.1 and 1.9 ng mL(-1) for Cu(2+), Co(2+) and Ni(2+) along with preconcentration factors of 30 and for these ions and enrichment factor of 65, 58 and 67 for Cu(2+), Ni(2+) and Co(2+), respectively. The high efficiency of cloud point extraction to carry out the determination of analytes in complex matrices was demonstrated. The proposed procedure was applied to the analysis of biological, natural and wastewater, soil and blood samples.

  1. Comparison of two digestion procedures for the determination of lead in lichens by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Moreira, Fátima R.; Borges, Renato M.; Oliveira, Rosália M.

    2005-06-01

    The efficiency of two procedures for the digestion of lichen was investigated using a heating block and a microwave oven. In the open vessels, concentrated nitric acid was added to the samples, left for 1 h, and the addition of 30% (v / v) hydrogen peroxide completed the digestion. In the closed system, the complete digestion was performed using concentrated nitric acid and hydrogen peroxide, reducing the amount of chemicals, time and contamination risk. Both digestion methods gave comparable results, and recoveries were statistically not different. For a lichen sample spiked with 10 μg Pb, the recovery was 111% and 110% using microwave and heating block digestion, respectively, while it was 100% and 103% for a 100 μg Pb spike. For the determination by electrothermal atomic absorption spectrometry samples were diluted 20 times with water and a volume of 20 μL was injected into the graphite furnace without chemical modifier. Pyrolysis and atomization temperatures of 700 °C and 1500 °C, respectively, were used. The characteristic mass was 8.4 ± 0.6 pg for aqueous calibration solutions and 8.9 ± 0.8 pg for samples. Calibration was against matrix matched standards. The recovery test showed some contamination problem with the lowest concentrations in both procedures. The detection limits were 4.4 μg L - 1 with microwave oven and 5.4 μg L - 1 with the heating block in the undiluted blank.

  2. Determination of methylmercury by electrothermal atomic absorption spectrometry using headspace single-drop microextraction with in situ hydride generation

    NASA Astrophysics Data System (ADS)

    Gil, Sandra; Fragueiro, Sandra; Lavilla, Isela; Bendicho, Carlos

    2005-01-01

    A new method is proposed for preconcentration and matrix separation of methylmercury prior to its determination by electrothermal atomic absorption spectrometry (ETAAS). Generation of methylmercury hydride (MeHgH) from a 5-ml solution is carried out in a closed vial and trapped onto an aqueous single drop (3-μl volume) containing Pd(II) or Pt(IV) (50 and 10 mg/l, respectively). The hydrogen evolved in the headspace (HS) after decomposition of sodium tetrahydroborate (III) injected for hydride generation caused the formation of finely dispersed Pd(0) or Pt(0) in the drop, which in turn, were responsible for the sequestration of MeHgH. A preconcentration factor of ca. 40 is achieved with both noble metals used as trapping agents. The limit of detection of methylmercury was 5 and 4 ng/ml (as Hg) with Pd(II) or Pt(IV) as trapping agents, and the precision expressed as relative standard deviation was about 7%. The preconcentration system was fully characterised through optimisation of the following variables: Pd(II) or Pt(IV) concentration in the drop, extraction time, pH of the medium, temperatures of both sample solution and drop, concentration of salt in the sample solution, sodium tetrahydroborate (III) concentration in the drop and stirring rate. The method has been successfully validated against two fish certified reference materials (CRM 464 tuna fish and CRM DORM-2 dogfish muscle) following selective extraction of methylmercury in 2 mol/l HCl medium.

  3. Determination of Trace Silver in Water Samples by Online Column Preconcentration Flame Atomic Absorption Spectrometry Using Termite Digestion Product

    PubMed Central

    Bianchin, Joyce Nunes; Martendal, Edmar; Carasek, Eduardo

    2011-01-01

    A new method for Ag determination in water samples using solid phase extraction (SPE) coupled to a flow injection system and flame atomic absorption spectrometry was developed. The sorbent used for Ag preconcentration and extraction was the termite digestion product. Flow and chemical variables of the system were optimized through a multivariate procedure. The factors selected were adsorbent mass, buffer type and concentration, sample pH, and sample flow rate. The detection limit and precision were 3.4 μg L−1 and 3.8% (n = 6, 15 μg L−1), respectively. The enrichment factor and the linear working range were, respectively, 21 and 10–50 μg L−1. Results for recovery tests using different water samples were between 96 and 107%. The proposed methodology was applied with success for the determination of Ag in water used to wash clothes impregnated with silver nanoparticles, supplied by a factory located in Santa Catarina, Brazil. PMID:21804766

  4. Metal furnace heated by flame as a hydride atomizer for atomic absorption spectrometry: Sb determination in environmental and pharmaceutical samples.

    PubMed

    Figueiredo, Eduardo Costa; Dĕdina, Jirí; Arruda, Marco Aurélio Zezzi

    2007-10-15

    The present work describes a metallic hydride atomizer for atomic absorption spectrometry, by evaluating the performance of the Inconel 600((R)) tube. For this purpose, stibine was used as the model volatile compound and antimony determination in river and lake sediments and in pharmaceutical samples was carried out to assess the metal furnace performance. Some parameters are evaluated such as those referring to the generation and transport of the hydride (such as KBH(4) and acid concentrations, carrier gas flow rate, injected volume, etc.), as well as those referring to the metal furnace (such as tube hole area, flame composition, long-term stability, etc.). The method presents linear Sb concentration from 2 to 80mugL(-1) range (r>0.998; n=3) and the analytical frequency of ca. 140h(-1). The limit of detection (LOD) is 0.23mugL(-1) and the precision, expressed as R.S.D., is less than 5% (40mugL(-1); n=10). The accuracy is evaluated through the reference materials, and the results are similar at 95% confidence level according to the t-test.

  5. Determination of cadmium and lead in beverages after leaching from pewter cups using graphite furnace atomic absorption spectrometry.

    PubMed

    Dessuy, Morgana B; Vale, Maria Goreti R; Welz, Bernhard; Borges, Aline R; Silva, Márcia M; Martelli, Patrícia B

    2011-07-15

    Two simple methods have been developed to determine cadmium and lead in different kinds of beverages and vinegar leached from pewter cups produced in Brazil. Leaching experiments have been carried out with different solutions: beer, sugar cane spirit, red and white wine, vinegar and a 3% acetic acid solution. The solutions were kept in cups with and without solder for 24h. Lead and cadmium have been determined using graphite furnace atomic absorption spectrometry with deuterium background correction. The limits of detection were 0.05 and 1.4 μg L(-1), and the characteristic mass was 1.0 pg and 19 pg for Cd and Pb, respectively. With the developed methods it was possible to determine accurately cadmium and lead by direct analysis in these liquids and to evaluate the leaching of these metals from pewter cups. The results presented in this work show that pewter cups are not cadmium- and lead-free; this point goes against the manufacturers' declaration that their products are lead-free.

  6. Tellurium speciation analysis using hydride generation in situ trapping electrothermal atomic absorption spectrometry and ruthenium or palladium modified graphite tubes.

    PubMed

    Yildirim, Emrah; Akay, Pınar; Arslan, Yasin; Bakirdere, Sezgin; Ataman, O Yavuz

    2012-12-15

    Speciation of tellurium can be achieved by making use of different kinetic behaviors of Te(IV) and Te(VI) upon their reaction with sodium borohydride using hydride generation. While Te(IV) can form H(2)Te, Te(VI) will not form any volatile species during the course of hydride formation and measurement by atomic absorption spectrometry. Quantitative reduction of Te(VI) was achieved through application of a microwave assisted prereduction of Te(VI) in 6.0 mol/L HCl solution. Enhanced sensitivity was achieved by in situ trapping of the generated H(2)Te species in a previously heated graphite furnace whose surface was modified using Pd or Ru. Overall efficiency for in situ trapping in pyrolytically coated graphite tube surface was found to be 15% when volatile analyte species are trapped for 60s at 300°C. LOD and LOQ values were calculated as 0.086 ng/mL and 0.29 ng/mL, respectively. Efficiency was increased to 46% and 36% when Pd and Ru surface modifiers were used, respectively. With Ru modified graphite tube 173-fold enhancement was obtained over 180 s trapping period with respect to ETAAS; the tubes could be used for 250 cycles. LOD values were 0.0064 and 0.0022 ng/mL for Pd and Ru treated ETAAS systems, respectively, for 180 s collection of 9.6 mL sample solution.

  7. Determination of platinum and palladium in road dust after their separation on immobilized fungus by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Woińska, Sylwia; Godlewska-Żyłkiewicz, Beata

    2011-07-01

    A flow solid phase extraction procedure based on biosorption of Pt(IV) and Pd(II) on Aspergillus sp. immobilized on cellulose resin Cellex-T was proposed for the separation and preconcentration of Pt and Pd before their determination by electrothermal atomic absorption spectrometry (ETAAS). The analytical conditions including sample pH, eluent type, flow rates of sample and eluent solutions were examined. The analytes were selectively retained on the biosorbent in acidic medium (pH 1) and subsequently eluted from the column with 1 mL of thiourea solution (0.25 mol L - 1 thiourea in 0.3 mol L - 1 HCl). The reproducibility of the procedure was below 5%. The limit of detection of the method was 0.020 ng mL - 1 for Pt and 0.012 ng mL - 1 for Pd. The method validation was performed by analysis of certified reference materials BCR-723 (tunnel dust) and SARM-76 (platinum ore). The developed separation procedure was applied to the determination of Pt and Pd in road dust samples by ETAAS. The applied biosorbent is characterized by high sorption capacity: 0.47 mg g - 1 for Pt and 1.24 mg g - 1 for Pd.

  8. Determination of molybdenum in plants by vortex-assisted emulsification solidified floating organic drop microextraction and flame atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Oviedo, Jenny A.; Fialho, Lucimar L.; Nóbrega, Joaquim A.

    2013-08-01

    A fast and sensitive procedure for extraction and preconcentration of molybdenum in plant samples based on solidified floating organic drop microextraction combined with flame atomic absorption spectrometry and discrete nebulization was developed. 8-Hydroxyquinoline (8-HQ) was used as complexing agent. The experimental conditions established were: 0.5% m v- 1 of 8-HQ, 60 μL of 1-undecanol as the extractant phase, 2 min vortex extraction time, centrifugation for 2 min at 2000 rpm, 10 min into an ice bath and discrete nebulization by introducing 200 μL of solution. The calibration curve was linear from 0.02 to 4.0 mg L- 1 with a limit of detection of 4.9 μg L- 1 and an enhancement factor of 67. The relative standard deviations for ten replicate measurements of 0.05 and 1.0 mg L- 1 Mo were 6.0 and 14.5%, respectively. The developed procedure was applied for determining molybdenum in corn samples and accuracy was proved using certified reference materials.

  9. A new coupling of ionic liquid based-single drop microextraction with tungsten coil electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Wen, Xiaodong; Deng, Qingwen; Wang, Jiwei; Yang, Shengchun; Zhao, Xia

    2013-03-01

    In this work, an improved method of ionic liquid based-single drop microextraction (IL-SDME) preconcentration was firstly coupled with tungsten coil electrothermal atomic absorption spectrometry (W-coil ET-AAS) detection. The new coupling was developed and applied for the determination of ultra-trace cadmium. Experimental parameters influencing the performance of IL-SDME as well as instrumental conditions were studied systematically, including IL-drop volume, chelating agent concentration, pH, stirring rate and time, heating program of W-coil ET-AAS, flow rate of carrier gas. Under the optimal conditions, the limit of detection (LOD) for cadmium was 0.015 μg L-1 (sampling amount on W-coil was 10 μL). The sensitivity enhancement factor was 42, while the improvement factor of LOD was 33. The established method was applied to determine cadmium in standard reference materials of rice and real water samples successfully. The developed IL-SDME-W-coil ET-AAS coupling represents a simple, green and highly sensitive method for cadmium determination.

  10. Determination of tributyltin in toluene extract from sea water by graphite furnace atomic absorption spectrometry with a new matrix modifier.

    PubMed

    Gong, B; Liu, Y; Xu, Y; Lin, T

    1997-06-01

    A new matrix modifier composed of calcium and chromium[VI] was proposed for the determination of tributyltin (TBT) in toluene extract from sea water containing sediment by graphite furnace atomic absorption spectrometry (GFAAS). Fourteen inorganic and organic compounds (barium, calcium, chromium[VI], lanthanum, magnesium, nickel, palladium, strontium, calcium-chromium[VI], calcium-strontium, nickel isocaprylate, 5%-, 10%-aqueous solution of ascorbic acid and toluene-saturated solution of ascorbic acid) as a matrix modifier were comparatively studied and a matrix modifier composed from 5 microg of calcium and 1 microg of chromium[VI] was found to give the best performance. The interference effects of co-existing elements in sea water containing sediment (aluminium, iron, magnesium, sodium and strontium) were studied. TBT in eight toluene extracts was determined by GFAAS with the proposed matrix modifier. The relative standard deviation was 3.0% for 63 ng ml(-1) of TBT (n = 11). The recoveries were 88-104%. The characteristic mass was 7 pg. The linearity range was 0-250 ng mg(-1).

  11. Direct determination of Cu and Zn in fruit juices and bovine milk by thermospray flame furnace atomic absorption spectrometry.

    PubMed

    Nascentes, Clésia C; Arruda, Marco A Z; Nogueira, Ana Rita A; Nóbrega, Joaquim A

    2004-11-15

    In the present work, thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was employed for Cu and Zn determination in bovine milk and fruit juice samples without any pretreatment. TS-FF-AAS system was optimized and a sample volume of 300mul was injected into the carrier stream (0.014moll(-1) HNO(3) at a flow rate of 0.4mlmin(-1)), and it was introduced into a hot Ni tube. The detection limits obtained for Cu and Zn in aqueous solution were 2.2 and 0.91mugl(-1), respectively, and 3.2mugl(-1) for Cu in a medium containing water-soluble tertiary amines. The relative standard deviations varied from 2.7 to 4.2% (n=12). Sample preparation was carried out by simple dilution in water or in water-soluble tertiary amines medium. Accuracy was checked by performing addition-recovery experiments as well as by using reference materials (whole milk powder, non-fat milk powder, and infant formula). Recoveries varied from 97.7 to 105.3% for Cu and Zn. All results obtained for reference materials were in agreement with certified values at a 95% confidence level.

  12. Determination of vanadium in soils and sediments by the slurry sampling graphite furnace atomic absorption spectrometry using permanent modifiers.

    PubMed

    Dobrowolski, Ryszard; Adamczyk, Agnieszka; Otto, Magdalena

    2013-09-15

    A new analytical procedure for vanadium (V) determination in soils and sediments by the slurry sampling graphite furnace atomic absorption spectrometry (slurry sampling GFAAS) using the mixed permanent modifiers is described. Moreover, the comparison of action of the modifiers based on the iridium (Ir) and carbide-forming elements: tungsten (W) and niobium (Nb) deposited on the graphite tubes is studied, especially in terms of their analytical utility and determination sensitivity. The mechanism of their action was investigated using an X-ray diffraction technique (XRD) and scanning electron microscopy (SEM) equipped with an energy dispersive X-ray detector (EDX). Finally, the mixture of 0.3 μg of Ir and 0.04 μg of Nb was used for the graphite tube permanent modification. The analytical procedure was optimized on the basis of the data from pyrolysis and atomization temperature curves studies. The results obtained for the four certified reference materials (marine sediments: PACS-1 and MESS-1, lake sediment: SL-1, soil: San Joaquin Soil SRM 2709), using the slurry sampling GFAAS and the standard calibration method, were in good agreement with the certified values. The detection and quantification limits and characteristic mass calculated for the proposed procedure were 0.04 µg/g, 0.16 µg/g and 11.9 pg, respectively. The precision (RSD% less than 8%) and the accuracy of vanadium determination in the soil and sediment samples were acceptable.

  13. The determination of wear metals in used lubricating oils by flame atomic absorption spectrometry using sulphanilic acid as ashing agent.

    PubMed

    Ekanem, E J; Lori, J A; Thomas, S A

    1997-11-01

    A simple and reliable ashing procedure is proposed for the preparation of used lubricating oil samples for the determination of calcium, magnesium, zinc, iron, chromium and nickel by flame atomic absorption spectrometry. Sulphanilic acid was added to oil samples and the mixture coked and the coke ashed at 550 degrees C. The solutions of the ash were analysed by flame AAS for the metals. The release of calcium, zinc, iron and chromium was improved by the addition of sulphanilic acid to samples. The relative standard deviations of metal concentration results in the initial oil samples were 1.5% for Ca (1500 mg l(-1) level), 0.3% for Mg (100 mg l(-1) level), 3.1% for Zn (1500 mg l(-1) level), 0.7% for Fe (500 mg l(-1) level), 0.02% for Cr (50 mg l(-1) level) and 0.002% for Ni (10 mg l(-1) level). The optimum sample size for efficient metal release was 20 g while the optimum sulphanilic acid to oil ratio was 0.05 g per gram of oil for Zn and Cr and 0.10 g for Ca and Fe. Results obtained by this procedure were highly reproducible and comparable with those obtained for the same samples using standard procedures.

  14. Evaluation of ammonia as diluent for serum sample preparation and determination of selenium by graphite furnace atomic absorption spectrometry*1

    NASA Astrophysics Data System (ADS)

    Hernández-Caraballo, Edwin A.; Burguera, Marcela; Burguera, José L.

    2002-12-01

    A method for the determination of total selenium in serum samples by graphite furnace atomic absorption spectrometry was evaluated. The method involved direct introduction of 1:5 diluted serum samples (1% v/v NH 4OH+0.05% w/v Triton X-100 ®) into transversely heated graphite tubes, and the use of 10 μg Pd+3 μg Mg(NO 3) 2 as chemical modifier. Optimization of the modifier mass and the atomization temperature was conducted by simultaneously varying such parameters and evaluating both the integrated absorbance and the peak height/peak area ratio. The latter allowed the selection of compromise conditions rendering good sensitivity and adequate analyte peak profiles. A characteristic mass of 49 pg and a detection limit (3s) of 6 μg 1 -1 Se, corresponding to 30 μg l -1 Se in the serum sample, were obtained. The analyte addition technique was used for calibration. The accuracy was assessed by the determination of total selenium in Seronorm™ Trace Elements Serum Batch 116 (Nycomed Pharma AS). The method was applied for the determination of total selenium in ten serum samples taken from individuals with no known physical affection. The selenium concentration ranged between 79 and 147 μg l -1, with a mean value of 114±22 μg l -1.

  15. Evaluation of oxidant media for the determination of lead in food slurries by hydride generation atomic absorption spectrometry.

    PubMed

    Madrid, Y; Bonilla, M; Cámara, C

    1990-05-01

    Several oxidant media were evaluated for the generation of lead hydride from slurry samples and their application to the determination of lead in vegetables and fish by hydride generation atomic absorption spectrometry. Three oxidant - acid media were compared: hydrogen peroxide - nitric acid, ammonium persulphate - nitric acid and potassium dichromate - lactic acid. The powdered samples were suspended in Triton X-100 and shaken with 10.0 g of blown zirconia spheres until a slurry was formed. The potassium dichromate - lactic acid medium was the most satisfactory for the determination of lead in fish and vegetables, providing the lowest detection limits as a result of its high sensitivity and low blank values. The ammonium persulphate - nitric acid medium gave good accuracy, precision and selectivity for vegetables (1-2 p.p.m. of lead); however, with fish (0.1-1 p.p.m. of lead) it was only a semi-quantitative medium for the determination of lead owing to its lack of sensitivity and selectivity. The hydrogen peroxide - nitric acid medium was unsatisfactory for the generation of lead hydride from slurry samples because of decomposition of hydrogen peroxide by the organic matter in the sample.

  16. Determination of lead and manganese in biological samples and sediment using slurry sampling and flame atomic absorption spectrometry.

    PubMed

    Vieira, Daniel Rodrigues; Castro, Jacira Teixeira; Lemos, Valfredo Azevedo

    2011-01-01

    A procedure was developed for the determination of lead (Pb) and manganese (Mn) using slurry sampling. The two elements were detected using flame atomic absorption spectrometry with a slotted tube atom trap. Slurries were prepared by adding nitric acid solution (0.30%, w/v) to a powdered sample (0.10 g). After homogenization by ultrasonic bath for 15 min, the slurries were introduced directly into the detection equipment. Some conditions of the procedure were evaluated, such as acid concentration, presence of surfactants, and sonication time. Under optimized conditions, the LODs and LOQs achieved were 0.8 and 2.6 microg/g for Pb and 0.5 and 1.6 microg/g for Mn, respectively. The precision obtained varied between 3.1 and 5.8% (Mn), and 2.6 and 5.4% (Pb) for slurries of shrimp and sediment. The analytical curves were established using aqueous standards in nitric acid solutions. The accuracy of the method was assessed through the determination of Pb and Mn in the following certified reference materials: ERM-CE 278 (mussel tissue), CRM 397 (human hair), and SRM 1646a (estuarine sediment). The proposed procedure was successfully applied to the determination of Pb and Mn in six samples of shrimp powder, seasoning, and river sediment. The levels of Mn detected varied from 2.2 to 71.3 microg/g; Pb was detected in only one sediment sample (4.3 microg/g).

  17. [Trace Analysis of Lead in Copper Gluconate by Atomic Absorption Spectrometry after Separation by Co-Precipitation with Bismuth].

    PubMed

    Ito, Michio; Ishiguro, Satoshi; Takahashi, Fumihito; Nomura, Takakazu; Sugimoto, Toshiaki; Nishimura, Tsutomu

    2015-01-01

    In order to determine trace amounts of lead in copper gluconate by atomic absorption spectrometry (AAS), the authors investigated a separation and pre-concentration procedure using a co-precipitation technique with bismuth. After ashing 2.0 g of the sample by means of a dry process, the ash was dissolved in (1→100) nitric acid and 75 μg of bismuth was added. Lead was co-precipitated by using an ammonium solution controlled to pH 9.5-10.5. The precipitate was left at room temperature for over 15 minutes to age, and then washed with a (3→100) ammonium solution three times. The precipitate was dissolved in (1→100) nitric acid and then analyzed by AAS. The quantification limit of this method was 0.5 mg/kg, and the trueness, repeatability and intermediate precision were 99.6%, 4.2% and 4.2% at the spiked concentration of 0.5 mg/kg, and 94.4%, 2.8% and 4.0% at the spiked concentration of 5.0 mg/kg, respectively. Thus, the present method for trace analysis of lead in copper gluconate was validated.

  18. Preconcentration of lead using solidification of floating organic drop and its determination by electrothermal atomic absorption spectrometry

    PubMed Central

    Chamsaz, Mahmoud; Akhoundzadeh, Jeiran; Arbab-zavar, Mohammad Hossein

    2012-01-01

    A simple microextraction method based on solidification of a floating organic drop (SFOD) was developed for preconcentration of lead prior to its determination by electrothermal atomic absorption spectrometry (ETAAS). Ammonium pyrolidinedithiocarbamate (APDC) was used as complexing agent, and the formed complex was extracted into a 20 μL of 1-undecanol. The extracted complex was diluted with ethanol and injected into a graphite furnace. An orthogonal array design (OAD) with OA16 (45) matrix was employed to study the effects of different parameters such as pH, APDC concentration, stirring rate, sample solution temperature and the exposure time on the extraction efficiency. Under the optimized experimental conditions the limit of detection (based on 3 s) and the enhancement factor were 0.058 μg L−1 and 113, respectively. The relative standard deviation (RSD) for 8 replicate determinations of 1 μg L−1 of Pb was 8.8%. The developed method was validated by the analysis of certified reference materials and was successfully applied to the determination of lead in water and infant formula base powder samples. PMID:25685441

  19. Determination of tin and titanium in soils, sediments and sludges using electrothermal atomic absorption spectrometry with slurry sample introduction.

    PubMed

    López-García, Ignacio; Arnau-Jerez, Isabel; Campillo, Natalia; Hernández-Córdoba, Manuel

    2004-02-06

    Fast-heating programmes for determining titanium and tin in soils, sediments and sludges using electrothermal atomic absorption spectrometry (ETAAS) with slurry sampling are developed. For titanium determination, suspensions are prepared by weighing 5-40mg of sample and adding 25ml of a solution containing 50% (v/v) concentrated hydrofluoric acid. For tin determination, suspensions are prepared by weighing up to 300mg of sample and then adding 1ml of a solution containing 25% (v/v) concentrated hydrofluoric acid. Palladium (30mug) and ammonium dihydrogen phosphate (7% w/v) are used as matrix modifiers for titanium and tin, respectively. Prior mild heating in a microwave oven is recommended for titanium determination. Calibration is carried out using aqueous standards. The tin and titanium contents of a number of samples obtained by using the slurry approach agree with those obtained by means of a procedure based on the total dissolution of the samples using microwave oven digestion. The reliability of the procedures is also confirmed by analysing several certified reference materials.

  20. Fast determination of lead in lake sediment samples using electrothermal atomic absorption spectrometry with slurry samples introduction.

    PubMed

    Barałkiewicz, Danuta

    2002-01-04

    Lead concentration in lake sediment samples has been determined by means of ultrasonic slurry sampling electrothermal atomic absorption spectrometry USSS-ETAAS. The soil samples were suspended (0.025-0.15% w/v slurry) in four different liquid media containing 0.5% (v/v) nitric acid, 5% (v/v) nitric acid, 0.5% nitric acid+Triton X-100 and 5% nitric acid+Triton X-100. The effects of the instrumental operating conditions and slurry preparation on the signal were examined. Palladium and magnesium were used as modifiers to improve the signal quality. The procedure was validated by analysis of the certified reference lake sediment material LKSD-1, LKSD-2, LKSD-3 and LKSD-4. All analytical recoveries for lead in slurried lake sediment samples were satisfactory and varied from 95 to 104%. Relative standard deviation (R.S.D.) values were 4.8, 4.7, 4.5 and 5.5. The detection limits LODs of lead were 0.52, 0.45, 0.35, and 0.22 mug g(-1) for mass of sample 0.025, 0.050, 0.10 and 0.15 U, respectively.

  1. Determination of aluminium and manganese in human scalp hair by electrothermal atomic absorption spectrometry using slurry sampling.

    PubMed

    Bermejo-Barrera, P; Moreda-Piñeiro, A; Moreda-Piñeiro, J; Bermejo-Barrera, A

    1998-04-01

    Methods for the determination of aluminium and manganese in human scalp hair samples by electrothermal atomic absorption spectrometry using the slurry sampling technique were developed. Palladium and magnesium nitrate were used as chemical modifiers. Hair samples were pulverized using a zirconia vibrational mill ball, and were prepared as aqueous slurries. Determinations can be performed in the linear ranges of 1.9-150 mug l(-1) Al(3+) and 0.03-10.0 mug l(-1) Mn(2+). Limits of detection of 0.9 mg kg(-1) and 27.6 mug kg(-1) were obtained for aluminium and manganese, respectively. The analytical recoveries were between 99.6 and 101.8% for aluminium and in the 98.3-101.3% range for manganese. The repeatability of the methods (n=11), slurry preparation procedure and ETAAS measurement, was 16.0 and 7.9% for aluminium and manganese, respectively. The methods were finally applied to the aluminium and manganese determination in 25 scalp hair samples from healthy adults. The levels for aluminium were between 8.21 and 74.08 mg kg(-1), while concentrations between 0.03 and 1.20 mg kg(-1) were found for manganese.

  2. Determination of nickel in saliva by electrothermal atomic absorption spectrometry using various chemical modifiers with Zeeman-effect background correction.

    PubMed

    Burguera, E; Sanchez de Briceño, A; Rondon, C E; Burguera, J L; Burguera, M; Carrero, P

    1998-07-01

    The profile of nickel signal using electrothermal atomic absorption spectrometry with deuterium and Zeeman-effect background correction is presented. The Zeeman effect system of background correction offered definitive advantages and therefore was used for the determination of nickel in saliva in the presence of various isomorphous metals. The highest nickel absorbance values corresponded at 200, 300, 300, 300, 600, and 200 ng of Tb, Mg, Sm, Lu, Tm, and Pd, respectively. On the other hand, the addition of Eu, Er, and Ho decreased the nickel signal. The presence on each modifier alone does not eliminate the matrix interference. However, the use of 200 ng of Pd in conjuction with 300 ng of Lu has a higher sensitivity, offers an advantage against interference from the background of saliva matrix and produces good recoveries (98 to 102% from unspiked and spiked saliva samples). The limit of detection was 0.11 micrograms/L for a characteristic mass of 16.6 pg of nickel using Pd-Lu as modifier. The within-batch precision varied between 0.8 and 1.5% relative standard deviations. The analysis of thirty samples of whole saliva gave an average of 0.81 +/- 0.30 of micrograms/L of Ni (range from 0.5 to 2.0 micrograms/L of Ni). The agreement between the observed and certified values obtained from a Seronorm Blood Serum Standard Reference Material was good.

  3. Preconcentration of gold ions from water samples by modified organo-nanoclay sorbent prior to flame atomic absorption spectrometry determination.

    PubMed

    Afzali, Daryoush; Mostafavi, Ali; Mirzaei, Mohammad

    2010-09-15

    In this work, the applicability of modified organo nanoclay as a new and easy prepared solid sorbent for the preconcentration of trace amounts of Au(III) ion from water samples is studied. The organo nanoclay was modified with 5-(4'-dimethylamino benzyliden)-rhodanine and used as a sorbent for separation of Au(III) ions. The sorption of gold ions was quantitative in the pH range of 2.0-6.0. Quantitative desorption occurred with 6.0 mL of 1.0 mol L(-1) Na(2)S(2)O(3). The amount of eluted Au(III) was measured using flame atomic absorption spectrometry. In the initial solution the linear dynamic range was in the range of 0.45 ng mL(-1) to 10.0 microg mL(-1), the detection limit was 0.1 ng mL(-1) and the preconcentration factor was 105. Also, the relative standard deviation was +/-2.3% (n=8 and C=2.0 microg mL(-1)) and the maximum capacity of the sorbent was 3.9 mg of Au(III) per gram of modified organo nanoclay. The influences of the experimental parameters including sample pH, eluent volume and eluent type, sample volume, and interference of some ions on the recoveries of the gold ion were investigated. The proposed method was applied for preconcentration and determination of gold in different samples.

  4. Determination of trace nickel in hydrogenated cottonseed oil by electrothermal atomic absorption spectrometry after microwave-assisted digestion.

    PubMed

    Zhang, Gai

    2012-01-01

    Microwave digestion of hydrogenated cottonseed oil prior to trace nickel determination by electrothermal atomic absorption spectrometry (ETAAS) is proposed here for the first time. Currently, the methods outlined in U.S. Pharmacopeia 28 (USP28) or British Pharmacopeia (BP2003) are recommended as the official methods for analyzing nickel in hydrogenated cottonseed oil. With these methods the samples may be pre-treated by a silica or a platinum crucible. However, the samples were easily tarnished during sample pretreatment when using a silica crucible. In contrast, when using a platinum crucible, hydrogenated cottonseed oil acting as a reducing material may react with the platinum and destroy the crucible. The proposed microwave-assisted digestion avoided tarnishing of sample in the process of sample pretreatment and also reduced the cycle of analysis. The programs of microwave digestion and the parameters of ETAAS were optimized. The accuracy of the proposed method was investigated by analyzing real samples. The results were compared with the ones by pressurized-PTFE-bomb acid digestion and ones obtained by the U.S. Pharmacopeia 28 (USP28) method. The new method involves a relatively rapid matrix destruction technique compared with other present methods for the quantification of metals in oil.

  5. Dispersive Liquid-Liquid Microextraction of Bismuth in Various Samples and Determination by Flame Atomic Absorption Spectrometry

    PubMed Central

    Daşbaşı, Teslima; Kartal, Şenol; Saçmacı, Şerife; Ülgen, Ahmet

    2016-01-01

    A dispersive liquid-liquid microextraction method for the determination of bismuth in various samples by flame atomic absorption spectrometry is described. In this method, crystal violet was used as counter positive ion for BiCl4− complex ion, chloroform as extraction solvent, and ethanol as disperser solvent. The analytical parameters that may affect the extraction efficiency like acidity of sample, type and amount of extraction and disperser solvents, amount of ligand, and extraction time were studied in detail. The effect of interfering ions on the analyte recovery was also investigated. The calibration graph was linear in the range of 0.040–1.00 mg L−1 with detection limit of 4.0 μg L−1 (n = 13). The precision as relative standard deviation was 3% (n = 11, 0.20 mg L−1) and the enrichment factor was 74. The developed method was applied successfully for the determination of bismuth in various water, pharmaceutical, and cosmetic samples and the certified reference material (TMDA-64 lake water). PMID:26881186

  6. Determination of Low Levels of Lead in Beer Using Solid-Phase Extraction and Detection by Flame Atomic Absorption Spectrometry

    PubMed Central

    Alves, Vanessa N.; Borges, Simone S. O.; Neto, Waldomiro B.; Coelho, Nívia M. M.

    2011-01-01

    In this study, a method for the determination of low concentrations of lead in beer samples using solid-phase extraction with a flow injection analysis system and detection by flame atomic absorption spectrometry (FAAS) was developed. Moringa oleifera seeds were used as a biosorbent material. Chemical and flow variables of the online preconcentration system, such as sample pH, preconcentration flow rate, eluent flow rate, eluent concentration, particle size, and sorbent mass, were studied. The optimum extraction conditions were obtained using a sample pH of 6.0, sample flow rate of 6.0 mL min−1, 63.0 mg of sorbent mass, and 2.0 mol L−1 HNO3 at a flow rate of 2.0 mL min−1 as the eluent. With the optimized conditions, the preconcentration factor, precision, detection limit, consumption index, and sample throughput were estimated as 93, 0.3% (10.0 μg L−1, n = 7), 7.5 μg L−1, 0.11 mL, and 23 samples per hour, respectively. The method developed was successfully applied to beer samples and recovery tests, with recovery ranging from 80% to 100%. PMID:22013389

  7. Nickel and strontium nitrates as modifiers for the determination of selenium in wine by Zeeman electrothermal atomic absorption spectrometry.

    PubMed

    Cvetković, J; Stafilov, T; Mihajlović, D

    2001-08-01

    A mixed matrix modifier of nickel and strontium nitrates was used as a chemical modifier for the determination of selenium in wines by Zeeman electrothermal atomic absorption spectrometry. Wine samples were heated on a boiling water bath with small amounts of nitric acid and hydrogen peroxide. For complete elimination of interference, especially from sulfates and phosphates, selenium is complexed with ammonium pyrolidinedithiocarbamate (APDTC), extracted into methyl isobutyl ketone (MIBK), and measured by ETAAS. The graphite furnace temperature program was optimized for both aqueous and organic solutions. Pyrolysis temperatures of 1300 degrees C and 800 degrees C were chosen for aqueous and organic solutions, respectively; 2700 degrees C and 2100 degrees C were used as optimum atomization temperatures for aqueous and organic solutions, respectively. The optimum modifier mass established is markedly lower than those presented in the literature. The platform atomization ensures pretreatment stabilization up to 1100 degrees C and 1600 degrees C, respectively, for organic and aqueous selenium solutions. The procedure was verified by the method of standard addition. The investigated wine samples originated from the different regions of the Republic of Macedonia. The selenium concentration varied from not detectable to 0.93 microg L(-1).

  8. Cloud point extraction and flame atomic absorption spectrometry determination of lead (II) in environmental and food samples.

    PubMed

    Soylak, Mustafa; Yilmaz, Erkan; Ghaedi, Mehrorang; Montazerozohori, Mortaza; Sheibani, Marjan

    2012-01-01

    A cloud point extraction procedure for the preconcentration of Pb2+ in various samples following complexation with 2,2'-(1E,1'E)-1,1'-(2,2'-azanediylbis(ethane-2,1-diyl)bis(azan-1-yl-1-ylidene)) bis(ethan-1-yl-1-ylidene)diphenol in Triton X-114 after centrifugation is reported. A 0.5 mL portion of methanol acidified with 1.0 M HNO3 was added to the surfactant-rich phase prior to analysis by flame atomic absorption spectrometry. The influence of analytical parameters--including pH, concentrations of ligand, Triton X-114, and HNO3, bath temperature, heating time, and centrifugation rate and time--were optimized, and the effect of the matrix ions on the recovery of Pb2+ was investigated. An LOD of 1.9 ng/mL along with a preconcentration factor of 50 with RSD of 1.0% for Pb2+ were achieved. The proposed procedure was applied to the analysis of various real samples.

  9. Automated on-line preconcentration of trace aqueous mercury with gold trap focusing for cold vapor atomic absorption spectrometry.

    PubMed

    Puanngam, Mahitti; Dasgupta, Purnendu K; Unob, Fuangfa

    2012-09-15

    A fully automated system for the determination of trace mercury in water by cold vapor atomic absorption spectrometry (CVAAS) is reported. The system uses preconcentration on a novel sorbent followed by liberation of the mercury and focusing by a gold trap. Mercury ions were extracted from water samples by passage through a solid phase sorbent column containing 2-(3-(2-aminoethylthio)propylthio)ethanamine modified silica gel. The captured mercury is released by thiourea and then elemental Hg is liberated by sodium borohydride. The vapor phase Hg is recaptured on a gold-plated tungsten filament. This is liberated as a sharp pulse (half-width<2 s) by directly electrically heating the tungsten filament in a dry argon stream. The mercury is measured by CVAAS; no moisture removal is needed. The effects of chloride and selected interfering ions were studied. The sample loading flow rate and argon flow rates for solution purging and filament sweeping were optimized. An overall 50-fold improvement in the limit of detection was observed relative to direct measurement by CVAAS. With a relatively modest multi-user instrument we attained a limit of detection of 35 ng L(-1) with 12% RSD at 0.20 μg L(-1) Hg level. The method was successfully applied to accurately determine sub-μg L(-1) level Hg in standard reference water samples.

  10. Method development for Cd and Hg determination in biodiesel by electrothermal atomic absorption spectrometry with emulsion sample introduction.

    PubMed

    Aranda, Pedro R; Gásquez, José A; Olsina, Roberto A; Martinez, Luis D; Gil, Raúl A

    2012-11-15

    A novel method for analysis of biodiesel by electrothermal atomic absorption spectrometry is described. This analytical strategy involves sample preparation as emulsions for routine and reliable determination of Cd and Hg. Several experimental conditions were investigated, including emulsion stability and composition, furnace temperature program and matrix modification. Different calibration strategies were also evaluated, being the analyte addition method preferred both for Cd and Hg. The accuracy was verified through comparison with an acid digestion in a microwave closed system. The injection repeatability was evaluated as the average relative standard deviation (R.S.D %) for five successive firings and was better than 4.4% for Cd and 5.4% Hg respectively. The detection limits, evaluated by the 3σ concept of calculation (n=10), were of 10.2 μg kg(-1) (0.9 μg L(-1)) for Hg and 0.3 μg kg(-1) (0.04 μg L(-1)) for Cd. This method was successfully applied to the determination of Cd and Hg in biodiesel samples obtained from local vendors.

  11. Algorithm development for intensity modulated continuous wave laser absorption spectrometry in atmospheric CO2 measurements

    NASA Astrophysics Data System (ADS)

    Lin, B.; Harrison, F. W.; Browell, E. V.; Dobler, J. T.; Bryant, R. B.

    2011-12-01

    Currently, NASA Langley Research Center (LaRC) and ITT are jointly developing algorithms for demonstration of range discrimination using ITT's laser absorption spectrometer (LAS), which is being evaluated for the future NASA Active Sensing of CO2 Emissions during Nights, Days, and Seasons (ASCENDS) mission. The objective of this Decadal Survey mission is to measure atmospheric column CO2 mixing ratios (XCO2) for improved determination of atmospheric carbon sources and sinks. Intensity Modulated Continuous Wave (IM-CW) techniques are used in this LAS approach. The LAS is designed to simultaneously measure CO2 and O2 columns, and these measurements are used to determine the required XCO2 column. The LAS measurements are enabled by the multi-channel operation of the instrument at 1.57 and 1.26-um for CO2 and O2, respectively. The algorithm development for the IM-CW techniques of the multi-channel LAS is focused on addressing key retrieval issues such as surface signal detection, thin cloud and/or aerosol layer rejection, vertical atmospheric range resolution, and optimizing the size of the measurement footprint. With these considerations, the modulation algorithm needs to maintain high enough signal-to-noise ratio (SNR) so that the mission scientific goals can be reached. A basic selection of the modulation algorithms that make XCO2 measurement and thin cloud rejection possible is the stepped frequency modulation scheme and a similar scheme of swept sine modulation. The differences between these two schemes for thin cloud rejection are small, assuming the proper selection of parameters is made. The stepped frequency approach is only a quantified version of swept sine method for the frequencies used. Swept sine scheme is a very common modulation technique for range discrimination, while the consideration of the stepped frequency scheme is based on the history of the rolling-tone modulation used in the instrument in previous successful column CO2 measurements. The

  12. Ionic liquid ultrasound assisted dispersive liquid-liquid microextraction method for preconcentration of trace amounts of rhodium prior to flame atomic absorption spectrometry determination.

    PubMed

    Molaakbari, Elaheh; Mostafavi, Ali; Afzali, Daryoush

    2011-01-30

    In this article, we consider ionic liquid based ultrasound-assisted dispersive liquid-liquid microextraction of trace amounts of rhodium from aqueous samples and show that this is a fast and reliable sample pre-treatment for the determination of rhodium ions by flame atomic absorption spectrometry. The Rh(III) was transferred into its complex with 2-(5-bromo-2-pyridylazo)-5-diethylamino phenol as a chelating agent, and an ultrasonic bath with the ionic liquid, 1-octyl-3-methylimidazolium bis (trifluoromethylsulfonyl) imide at room temperature was used to extract the analyte. The centrifuged rhodium complex was then enriched in the form of ionic liquid droplets and prior to its analysis by flame atomic absorption spectrometry, 300 μL ethanol was added to the ionic liquid-rich phase. Finally, the influence of various parameters on the recovery of Rh(III) was optimized. Under optimum conditions, the calibration graph was linear in the range of 4.0-500.0 ng mL(-1), the detection limit was 0.37 ng mL(-1) (3S(b)/m, n = 7) and the relative standard deviation was ±1.63% (n = 7, C = 200 ng mL(-1)). The results show that ionic liquid based ultrasound assisted dispersive liquid-liquid microextraction, combined with flame atomic absorption spectrometry, is a rapid, simple, sensitive and efficient analytical method for the separation and determination of trace amounts of Rh(III) ions with minimum organic solvent consumption.

  13. Determination of toxic elements in plastics from waste electrical and electronic equipment by slurry sampling electrothermal atomic absorption spectrometry.

    PubMed

    Santos, Mirian C; Nóbrega, Joaquim A; Baccan, Nivaldo; Cadore, Solange

    2010-06-15

    Cadmium, chromium, lead and antimony were determined in slurries prepared using pulverized samples of personal computers and mobile phones dispersed in dimethylformamide medium. Determinations were carried out by electrothermal atomic absorption spectrometry (ETAAS) using a graphite furnace atomic absorption spectrometer. The optimization of the experimental conditions (chemical modifier, pyrolysis time, pyrolysis temperature and atomization temperatures) was accomplished by evaluating pyrolysis and atomization curves. Optimization was also used to determine the temperatures corresponding to the best sensitivities and the lowest background signals. The pyrolysis temperatures were fixed at 600 degrees C (for Cd), 700 degrees C (for Pb), 1100 degrees C (for Sb), and 1200 degrees C (for Cr); atomization temperatures were established as 1400 degrees C (for Cd), 1300 degrees C (for Pb), 1900 degrees C (for Sb), and 2300 degrees C (for Cr), and the chemical modifier (50microg NH(4)H(2)PO(4)+3microg Mg(NO(3))(2) was used for Cd and Pb while 5microg Pd+3microg Mg(NO(3))(2) was used for Sb). The use of a chemical modifier for Cr determination was not necessary. The characteristic masses were 1.9pg for Cd, 32.3pg for Pb, 54.1pg for Sb, and 9.1pg for Cr. Calibration was performed using standard additions in a range of 5-20microgL(-1) for Cd, 5-30microgL(-1) for Cr, 12.5-50microgL(-1) for Pb, and 25-100microgL(-1) for Sb with linear correlation coefficients higher than 0.99. Limits of detection were 0.9, 1.4, 6.8, and 2.9microgL(-1) for Cd, Pb, Sb, and Cr, respectively. The results indicate that recoveries for all metals agreed at a 95% confidence level when a paired t-test was applied and presented good precision. The accuracy of the proposed method was evaluated by addition-recovery experiments, showing results in the 96-112% range, and also by comparison of the results using Student's t-test with another method developed using ETAAS for digested samples. Analyte

  14. Rhodium as permanent modifier for atomization of lead from biological fluids using tungsten filament electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Zhou, Ying; Parsons, Patrick J.; Aldous, Kenneth M.; Brockman, Paul; Slavin, Walter

    2002-04-01

    Rhodium (Rh) was investigated as a permanent modifier for the atomization of Pb from biological fluids in W-filament atomic absorption spectrometry (AAS). Heating the W-filament with a Rh solution provided a protective coating for subsequent determinations of Pb in blood and urine matrices. The W-filament AAS instrumentation used was based on a prototype design that utilized self-reversal background correction scheme and peak area measurements. We found that Rh not only stabilized Pb during the pyrolysis step, but also facilitated the removal of carbonaceous residues during the cleaning step, requiring much less power than with phosphate modifier. Thus, the filament lifetime was greatly extended to over 300 firings. Periodic reconditioning with Rh was necessary every 30 firings or so. Conditioning the filament with Rh also permitted direct calibration using simple aqueous Pb standards. The method detection limit for blood Pb was approximately 1.5 μg dl -1, similar to that reported previously. Potential interferences from concomitants such as Na, K, Ca and Mg were evaluated. Accuracy was verified using lead reference materials from the National Institute of Standards and Technology and the New York State Department of Health. Blood lead results below 40 μg dl -1 were within ±1 μg dl -1 of certified values, and within ±10% above 40 μg dl -1; within-run precision was ±10% or better. Additional validation was reported using proficiency test materials and human blood specimens. All blood lead results were within the acceptable limits established by regulatory authorities in the US. When measuring Pb in urine, sensitivity was reduced and matrix-matched calibration became necessary. The method of detection limit was 27 μg l -1 for urine Pb. Urine lead results were also validated using an acceptable range comparable to that established for blood lead by US regulatory agencies.

  15. Determination of inorganic and total mercury by vapor generation atomic absorption spectrometry using different temperatures of the measurement cell

    NASA Astrophysics Data System (ADS)

    Kaercher, Luiz Eduardo; Goldschmidt, Fabiane; Paniz, José Neri Gottfried; de Moraes Flores, Érico Marlon; Dressler, Valderi Luiz

    2005-06-01

    A simple and inexpensive laboratory-built flow injection vapor generation system coupled to atomic absorption spectrometry (FI-VG AAS) for inorganic and total mercury determination has been developed. It is based on the vapor generation of total mercury and a selective detection of Hg 2 + or total mercury by varying the temperature of the measurement cell. Only the inorganic mercury is measured when the quartz cell is at room temperature, and when the cell is heated to 650 °C or higher the total Hg concentration is measured. The organic Hg concentration in the sample is calculated from the difference between the total Hg and Hg 2 + concentrations. Parameters such as the type of acid (HCl or HNO 3) and its concentration, reductant (NaBH 4) concentration, carrier solution (HCl) flow rate, carrier gas flow rate, sample volume and quartz cell temperature, which influence FI-VG AAS system performance, were systematically investigated. The optimized conditions for Hg 2 + and total Hg determinations were: 1.0 mol l - 1 HCl as carrier solution, carrier flow rate of 3.5 ml min - 1 , 0.1% (m/v) NaBH 4, reductant flow rate of 1.0 ml min - 1 and carrier gas flow rate of 200 ml min - 1 . The relative standard deviation (RSD) is lower than 5.0% for a 1.0 μg l - 1 Hg solution and the limit of quantification (LOQ, 10 s) is 55 ng g - 1 . Certified samples of dogfish muscle (DORM-1 and DORM-2) and non-certified fish samples were analyzed, using a 6.0 mol l - 1 HCl solution for analyte extraction. The Hg 2 + and CH 3Hg + concentrations found were in agreement with certified ones.

  16. Determination of silicon and aluminum in silicon carbide nanocrystals by high-resolution continuum source graphite furnace atomic absorption spectrometry.

    PubMed

    Dravecz, Gabriella; Bencs, László; Beke, Dávid; Gali, Adam

    2016-01-15

    The determination of Al contaminant and the main component Si in silicon carbide (SiC) nanocrystals with the size-distribution of 1-8nm dispersed in an aqueous solution was developed using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS-GFAAS). The vaporization/atomization processes were investigated in a transversally heated graphite atomizer by evaporating solution samples of Al and Si preserved in various media (HCl, HNO3). For Si, the best results were obtained by applying a mixture of 5µg Pd plus 5µg Mg, whereas for Al, 10µg Mg (each as nitrate solution) was dispensed with the samples, but the results obtained without modifier were found to be better. This way a maximum pyrolysis temperature of 1200°C for Si and 1300°C for Al could be used, and the optimum (compromise) atomization temperature was 2400°C for both analytes. The Si and Al contents of different sized SiC nanocrystals, dispersed in aqueous solutions, were determined against aqueous (external) calibration standards. The correlation coefficients (R values) of the calibrations were found to be 0.9963 for Si and 0.9991 for Al. The upper limit of the linear calibration range was 2mg/l Si and 0.25mg/l Al. The limit of detection was 3µg/l for Si and 0.5µg/l for Al. The characteristic mass (m0) was calculated to be 389pg Si and 6.4pg Al. The Si and Al content in the solution samples were found to be in the range of 1.0-1.7mg/l and 0.1-0.25mg/l, respectively.

  17. Speciation of platinum in blood plasma and urine by micelle-mediated extraction and graphite furnace atomic absorption spectrometry.

    PubMed

    Mortada, Wael I; Hassanien, Mohammed M; El-Asmy, Ahmed A

    2013-10-01

    A highly sensitive and selective technique for the speciation of platinum by cloud point extraction prior to determination by graphite furnace atomic absorption spectrometry (GFAAS) was described. The separation of Pt(II) from Pt(IV) was performed in the presence of 4-(p-chlorophenyl)-1-(pyridin-2-yl)thiosemicarbazide (HCPTS) as chelating agent and Triton X-114 as a non-ionic surfactant. The extraction of Pt(II)-HCPTS complex needs temperature higher than the cloud point temperature of Triton X-114 and pH = 7, while Pt(IV) remains in the aqueous phase. The Pt(II) in the surfactant phase was analyzed by GFAAS, and the concentration of Pt(IV) was calculated by subtraction of Pt(II) from total platinum which was directly determined by GFAAS. The effect of pH, concentration of chelating agent, surfactant, and equilibration temperature were investigated. An enrichment factor of 42 was obtained for the preconcentration of Pt(II) with 50 mL solution. Under the optimum experimental conditions, the calibration curve was linear up to 30 μgL(-1) with detection limit of 0.08 μgL(-1) and the relative standard deviation was 1.8%. No considerable interference was observed due to the presence of coexisting anions and cations. The accuracy of the results was verified by analyzing different spiked samples (tap water, blood plasma and urine). The proposed method was applied to the speciation analysis of Pt in blood plasma and urine with satisfactory results.

  18. Determination of some heavy metal levels in soft drinks on the Ghanaian market using atomic absorption spectrometry method.

    PubMed

    Ackah, Michael; Anim, Alfred Kwablah; Zakaria, Nafisatu; Osei, Juliet; Saah-Nyarko, Esther; Gyamfi, Eva Tabuaa; Tulasi, Delali; Enti-Brown, Sheriff; Hanson, John; Bentil, Nash Owusu

    2014-12-01

    Twenty-three soft drink samples (i.e., four pineapple-based fruit drinks, eight citrus-based fruit juices, one soya-based drink, three cola carbonated drinks, one apple-based fruit drink, and six cocktail fruit drinks) were randomly purchased from retail outlets in an urban market in Accra and analyzed for the concentrations of iron, cobalt, cadmium, zinc, lead, and copper using flame atomic absorption spectrometry. The mean concentration of iron and cadmium were 0.723 ± 0.448 mg/L and 0.032 ± 0.012 mg/L, respectively. The mean cobalt concentration was 0.071 ± 0.049 mg/L, while the mean Zn concentration in the samples was 0.060 ± 0.097 mg/L. The mean concentrations of Pb and Cu in the fruit juice samples were 0.178 ± 0.091 mg/L and 0.053 ± 0.063 mg/L respectively. About 78 % of the samples exceeded the United States Environmental Protection Agency (USEPA) maximum contaminant level of 0.3 mg/L prescribed for iron, whereas all the samples exceeded the USEPA maximum contaminant level of 0.005 mg/L prescribed for cadmium. About 91 % of the samples exceeded the EU maximum contaminant level prescribed for lead insoft drinks.

  19. Restricted access carbon nanotubes for direct extraction of cadmium from human serum samples followed by atomic absorption spectrometry analysis.

    PubMed

    Barbosa, Adriano F; Barbosa, Valéria M P; Bettini, Jefferson; Luccas, Pedro O; Figueiredo, Eduardo C

    2015-01-01

    In this paper, we propose a new sorbent that is able to extract metal ions directly from untreated biological fluids, simultaneously excluding all proteins from these samples. The sorbent was obtained through the modification of carbon nanotubes (CNTs) with an external bovine serum albumin (BSA) layer, resulting in restricted access carbon nanotubes (RACNTs). The BSA layer was fixed through the interconnection between the amine groups of the BSA using glutaraldehyde as cross-linker. When a protein sample is percolated through a cartridge containing RACNTs and the sample pH is higher than the isoelectric point of the proteins, both proteins from the sample and the BSA layer are negatively ionized. Thus, an electrostatic repulsion prevents the interaction between the proteins from the sample on the RACNTs surface. At the same time, metal ions are adsorbed in the CNTs (core) after their passage through the chains of proteins. The Cd(2+) ion was selected for a proof-of-principle case to test the suitability of the RACNTs due to its toxicological relevance. RACNTs were able to extract Cd(2+) and exclude almost 100% of the proteins from the human serum samples in an online solid-phase extraction system coupled with thermospray flame furnace atomic absorption spectrometry. The limits of detection and quantification were 0.24 and 0.80 μg L(-1), respectively. The sampling frequency was 8.6h(-1), and the intra- and inter-day precisions at the 0.80, 15.0, and 30.0 μg L(-1) Cd(2+) levels were all lower than 10.1% (RSD). The recoveries obtained for human blood serum samples fortified with Cd(2+) ranged from 85.0% to 112.0%. The method was successfully applied to analyze Cd(2+) directly from six human blood serum samples without any pretreatment, and the observed concentrations ranged from

  20. Determination of calcium, magnesium and zinc in lubricating oils by flame atomic absorption spectrometry using a three-component solution.

    PubMed

    Zmozinski, Ariane V; de Jesus, Alexandre; Vale, Maria G R; Silva, Márcia M

    2010-12-15

    Lubricating oils are used to decrease wear and friction of movable parts of engines and turbines, being in that way essential for the performance and the increase of that equipment lifespan. The presence of some metals shows the addition of specific additives such as detergents, dispersals and antioxidants that improve the performance of these lubricants. In this work, a method for determination of calcium, magnesium and zinc in lubricating oil by flame atomic absorption spectrometry (F AAS) was developed. The samples were diluted with a small quantity of aviation kerosene (AVK), n-propanol and water to form a three-component solution before its introduction in the F AAS. Aqueous inorganic standards diluted in the same way have been used for calibration. To assess the accuracy of the new method, it was compared with ABNT NBR 14066 standard method, which consists in diluting the sample with AVK and in quantification by F AAS. Two other validating methods have also been used: the acid digestion and the certified reference material NIST (SRM 1084a). The proposed method provides the following advantages in relation to the standard method: significant reduction of the use of AVK, higher stability of the analytes in the medium and application of aqueous inorganic standards for calibration. The limits of detection for calcium, magnesium and zinc were 1.3 μg g(-1), 0.052 μg g(-1) and 0.41 μg g(-1), respectively. Concentrations of calcium, magnesium and zinc in six different samples obtained by the developed method did not differ significantly from the results obtained by the reference methods at the 95% confidence level (Student's t-test and ANOVA). Therefore, the proposed method becomes an efficient alternative for determination of metals in lubricating oil.

  1. UV-photochemical vapor generation of selenium for atomic absorption spectrometry: Optimization and 75Se radiotracer efficiency study

    NASA Astrophysics Data System (ADS)

    Rybínová, Marcela; Musil, Stanislav; Červený, Václav; Vobecký, Miloslav; Rychlovský, Petr

    2016-09-01

    Volatile selenium compounds were generated UV-photochemically in the continuous flow mode using four UV-photoreactors differing in the material of the reaction coil; Teflon tubing and quartz tubes with various inner diameters and wall thicknesses were tested. Atomic absorption spectrometry with an externally heated quartz furnace atomizer was employed as the detector. The relevant experimental generation parameters were optimized and the basic analytical characteristics were determined. Using formic acid as the photochemical agent, limits of detection achieved for selenium were in the range 46-102 ng L- 1 in dependence on the type of UV-photoreactor employed. When nitric acid was also added to the photochemical agent, the limits of detection were reduced to 27-44 ng L- 1. The repeatability did not exceed 2.4% (5 μg L- 1 Se(IV), n = 10). Experiments with 75Se radiotracer have been performed for the first time to quantify the efficiency of UV-photochemical vapor generation (UV-PVG) of selenium. The highest efficiency of 67 ± 1% was obtained for a UV-photoreactor containing a quartz reaction coil (2.0 mm i.d., 4.0 mm o.d.). The generation efficiency of 61 ± 1% was obtained for a Teflon reaction coil (1.0 mm i.d., 1.4 mm o.d.). Mapping of the radiotracer distribution in the individual parts of the apparatus did not reveal substantial transport losses of the analyte in the UV-PVG system.

  2. Evidence for aluminum-binding erythropoietin by size-exclusion chromatography coupled to electrothermal absorption atomic spectrometry.

    PubMed

    Veiga, Marlei; Bohrer, Denise; Noremberg, Simone; do Nascimento, Paulo C; de Carvalho, Leandro M

    2011-11-01

    Erythropoietin (EPO) is a glycoprotein that stimulates erythropoiesis and is clinically used for treating anemia during chronic renal failure and for anemia in preterm infants. EPO formulations usually have elevated rates of contamination due to aluminum (Al), which is toxic to both types of patients. Size-exclusion chromatography (SEC) coupled with graphite furnace atomic absorption spectrometry (GF AAS) was employed to separate proteins and to quantify the amount of aluminum present in the elution volume corresponding to EPO and, therefore, to evaluate possible binding. Because EPO formulations contain human serum albumin (HSA), a chromatographic method was optimized for the separation of these proteins. Subsequent to the chromatographic separation, 1-mL fractions of the column effluent were collected, and the Al content in these aliquots was measured by GF AAS. EPO and HSA samples were incubated with Al for 4h at 4°C and 37°C as well as for 16 h at 4°C and 37°C. Afterwards, they were injected into the chromatographic system. These samples were also submitted to ultrafiltration (10 and 50 kDa membranes), and Al was measured in the ultrafiltrates. The results showed that Al was present in the eluent volume corresponding to the EPO peak but not in the HSA peak in the chromatograms. Temperature strengthened the interaction because the Al present in the EPO fraction was 3 times higher at 37°C compared to 4°C. Thirty-eight percent of the Al present in a 2.4 μg/mL EPO standard solution, and approximately 50% of the Al in formulation samples containing approximately 11 μg/mL EPO and either citrate or phosphate, were non-ultrafiltrable, which suggests that EPO is an effective Al acceptor in vitro.

  3. Comparison of two methods for blood lead analysis in cattle: graphite-furnace atomic absorption spectrometry and LeadCare(R) II system.

    PubMed

    Bischoff, Karyn; Gaskill, Cynthia; Erb, Hollis N; Ebel, Joseph G; Hillebrandt, Joseph

    2010-09-01

    The current study compared the LeadCare(R) II test kit system with graphite-furnace atomic absorption spectrometry for blood lead (Pb) analysis in 56 cattle accidentally exposed to Pb in the field. Blood Pb concentrations were determined by LeadCare II within 4 hr of collection and after 72 hr of refrigeration. Blood Pb concentrations were determined by atomic absorption spectrometry, and samples that were coagulated (n = 12) were homogenized before analysis. There was strong rank correlation (R(2) = 0.96) between atomic absorption and LeadCare II (within 4 hr of collection), and a conversion formula was determined for values within the observed range (3-91 mcg/dl, although few had values >40 mcg/dl). Median and mean blood pb concentrations for atomic absorption were 7.7 and 15.9 mcg/dl, respectively; for LeadCare II, medians were 5.2 mcg/dl at 4 hr and 4.9 mcg/dl at 72 hr, and means were 12.4 and 11.7, respectively. LeadCare II results at 4 hr strongly correlated with 72 hr results (R(2) = 0.96), but results at 72 hr were lower (P < 0.01). There was no significant difference between coagulated and uncoagulated samples run by atomic absorption. Although there have been several articles that compared LeadCare with other analytical techniques, all were for the original system, not LeadCare II. The present study indicated that LeadCare II results correlated well with atomic absorption over a wide range of blood Pb concentrations and that refrigerating samples for up to 72 hr before LeadCare II analysis was acceptable for clinical purposes.

  4. Determination of trace elements in coal and coal fly ash by joint-use of ICP-AES and atomic absorption spectrometry.

    PubMed

    Iwashita, Akira; Nakajima, Tsunenori; Takanashi, Hirokazu; Ohki, Akira; Fujita, Yoshio; Yamashita, Toru

    2007-01-15

    Microwave-acid digestion (MW-AD) followed by inductively coupled plasma-atomic emission spectrometry (ICP-AES), graphite furnace atomic absorption spectrometry (GFAAS), and hydride generation atomic absorption spectrometry (HGAAS) were examined for the determination of various elements in coal and coal fly ash (CFA). Eight certified reference materials (four coal samples and four CFA samples) were tested. The 10 elements (As, Be, Cd, Co, Cr, Mn, Ni, Pb, Sb, and Se), which are described in the Clean Air Act Amendments (CAAA), were especially considered. For coal, the HF-free MW-AD followed by ICP-AES was successful in the determination of various elements except for As, Be, Cd, Sb, and Se. These elements (except for Sb) were well-determined by use of GFAAS (Be and Cd) and HGAAS (As and Se). For CFA, the addition of HF in the digestion acid mixture was needed for the determination of elements, except for As, Sb, and Se, for which the HF-free MW-AD was applicable. The use of GFAAS (Be and Cd) or HGAAS (Sb and Se) resulted in the successful determination of the elements for which ICP-AES did not work well. The protocol for the determination of the 10 elements in coal and CFA by MW-AD followed by the joint-use of ICP-AES, GFAAS, and HGAAS was established.

  5. Determination of serum aluminum by electrothermal atomic absorption spectrometry: A comparison between Zeeman and continuum background correction systems

    NASA Astrophysics Data System (ADS)

    Kruger, Pamela C.; Parsons, Patrick J.

    2007-03-01

    Excessive exposure to aluminum (Al) can produce serious health consequences in people with impaired renal function, especially those undergoing hemodialysis. Al can accumulate in the brain and in bone, causing dialysis-related encephalopathy and renal osteodystrophy. Thus, dialysis patients are routinely monitored for Al overload, through measurement of their serum Al. Electrothermal atomic absorption spectrometry (ETAAS) is widely used for serum Al determination. Here, we assess the analytical performances of three ETAAS instruments, equipped with different background correction systems and heating arrangements, for the determination of serum Al. Specifically, we compare (1) a Perkin Elmer (PE) Model 3110 AAS, equipped with a longitudinally (end) heated graphite atomizer (HGA) and continuum-source (deuterium) background correction, with (2) a PE Model 4100ZL AAS equipped with a transversely heated graphite atomizer (THGA) and longitudinal Zeeman background correction, and (3) a PE Model Z5100 AAS equipped with a HGA and transverse Zeeman background correction. We were able to transfer the method for serum Al previously established for the Z5100 and 4100ZL instruments to the 3110, with only minor modifications. As with the Zeeman instruments, matrix-matched calibration was not required for the 3110 and, thus, aqueous calibration standards were used. However, the 309.3-nm line was chosen for analysis on the 3110 due to failure of the continuum background correction system at the 396.2-nm line. A small, seemingly insignificant overcorrection error was observed in the background channel on the 3110 instrument at the 309.3-nm line. On the 4100ZL, signal oscillation was observed in the atomization profile. The sensitivity, or characteristic mass ( m0), for Al at the 309.3-nm line on the 3110 AAS was found to be 12.1 ± 0.6 pg, compared to 16.1 ± 0.7 pg for the Z5100, and 23.3 ± 1.3 pg for the 4100ZL at the 396.2-nm line. However, the instrumental detection limits (3

  6. Effect of magnesium acetylacetonate on the signal of organic forms of vanadium in graphite furnace atomic absorption spectrometry.

    PubMed

    Kowalewska, Zofia; Welz, Bernhard; Castilho, Ivan N B; Carasek, Eduardo

    2013-01-15

    The aim of this work was to investigate the influence of magnesium acetylacetonate (MgA) on the signal of organic forms of vanadium in xylene solution by graphite furnace atomic absorption spectrometry. MgA alone or mixed with palladium acetylacetonate (PdA) was considered as a chemical modifier. It has been found that MgA does not improve, but decreases significantly the integrated absorbance of V in the form of alkyl-aryl sulfonates, acetylacetonates, porphyrins and in lubricating oils, while its effect is negligible in the case of "dark products" from petroleum distillation, i.e., heavy oil fractions and residues. The decrease is also observed in the presence of Pd. The MgA (or MgA+PdA) effect on the integrated absorbance of V has been studied using the following variants: different ways of modifier application, various pyrolysis temperature, additional application of air ashing, preliminary pretreatment with iodine and methyltrioctylammonium chloride, application of various graphite furnace heating systems (longitudinal or transverse) and various optical and background correction systems (medium-resolution line source spectrometer with deuterium background correction or high-resolution continuum source spectrometer). The experiments indicate formation of more refractory compounds as a possible reason for the decrease of the integrated absorbance for some forms of V in the presence of MgA. The application of MgA as a chemical modifier in V determination is not recommended. Results of this work have general importance as, apart from the intentional use of MgA as a modifier, organic Mg compounds, present in petroleum products for other reason (e.g. as an additive), can influence the signal of V compounds and hence the accuracy in V determination. Generally, petroleum products with known amount of V are recommended as standards; however, lubricating oils can be inadequate for "dark products" from petroleum distillation. In the case of unknown samples it is

  7. Determination of total mercury for marine environmental monitoring studies by solid sampling continuum source high resolution atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Mandjukov, Petko; Orani, Anna Maria; Han, Eunmi; Vassileva, Emilia

    2015-01-01

    The most critical step in almost all commonly used analytical procedures for Hg determination is the sample preparation due to its extreme volatility. One of the possible solutions of this problem is the application of methods for direct analysis of solid samples. The possibilities for solid sampling high resolution continuum source atomic absorption spectrometry (HR CS AAS) determination of total mercury in various marine environmental samples e.g. sediments and biota are object of the present study. The instrumental parameters were optimized in order to obtain reproducible and interference free analytical signal. A calibration technique based on the use of solid standard certified reference materials similar to the nature of the analyzed sample was developed and applied to various CRMs and real samples. This technique allows simple and reliable evaluation of the uncertainty of the result and the metrological characteristics of the method. A validation approach in line with the requirements of ISO 17025 standard and Eurachem guidelines was followed. With this in mind, selectivity, working range (0.06 to 25 ng for biota and 0.025 to 4 ng for sediment samples, expressed as total Hg) linearity (confirmed by Student's t-test), bias (1.6-4.3%), repeatability (4-9%), reproducibility (9-11%), and absolute limit of detection (0.025 ng for sediment, 0.096 ng for marine biota) were systematically assessed using solid CRMs. The relative expanded uncertainty was estimated at 15% for sediment sample and 8.5% for marine biota sample (k = 2). Demonstration of traceability of measurement results is also presented. The potential of the proposed analytical procedure, based on solid sampling HR CS AAS technique was demonstrated by direct analysis of sea sediments form the Caribbean region and various CRMs. Overall, the use of solid sampling HR CS AAS permits obtaining significant advantages for the determination of this complex analyte in marine samples, such as straightforward

  8. Temporal variations in gas temperature in an atomization stage of cadmium and tellurium evaluated by using the two-line method in graphite furnace atomic absorption spectrometry.

    PubMed

    Shimabukuro, Haruki; Ashino, Tetsuya; Wagatsuma, Kazuaki

    2008-09-01

    In order to discuss the atomization process of an analyte element occurring in a graphite furnace for atomic absorption spectrometry, we measured variations in the characteristic temperature with the progress of an atomization stage, by using a two-line method under the assumption of a Boltzmann distribution. For this purpose, iron was chosen as the analyte element. Also, the atomic absorption of two iron atomic lines, Fe I 372.0 nm and Fe I 373.7 nm, was simultaneously monitored as a probe for the temperature determination. This method enables variations in the gas temperature to be directly traced, yielding a temperature distribution closely related to the diffusion behavior of the probe element in the furnace. This temperature variation was very different from the furnace wall temperatures, which were monitored in conventional temperature control for atomic absorption spectrometry. Correlations between the gas temperature and the charring/atomizing temperatures in the heating program of the furnace were investigated. The atomization of cadmium and tellurium was also investigated by a comparison between the gas temperature with the wall temperature of the furnace. The atomic absorption of cadmium or tellurium appeared to be apart from the absorption of iron while the gas temperature was still low. Therefore, the analyte atoms could be atomized through direct contact with the wall of the graphite furnace, which has a much higher temperature compared to the gas atmosphere during atomization. Their atomization would be caused by conductive heating from the furnace wall rather than by radiant heating in the furnace.

  9. [Determination of Al, Be, Cd, Co, Cr, Mn, Ni, Pb, Se and Tl in whole blood by atomic absorption spectrometry without preliminary sample digestion].

    PubMed

    Ivanenko, N B; Ivanenko, A A; Solov'ev, N D; Navolotskiĭ, D V; Pavlova, O V; Ganeev, A A

    2014-01-01

    Methods of whole blood trace element determination by Graphite furnace atomic absorption spectrometry (in the variant of Zeeman's modulation polarization spectrometry) have been proposed. They do not require preliminary sample digestion. Furnace programs, modifiers and blood dilution factors were optimized. Seronorm™ human whole blood reference materials were used for validation. Dynamic ranges (for undiluted blood samples) were: Al 8 ¸ 210 мg/L; Be 0.3 ¸ 50 мg/L; Cd 0.2 ¸ 75 мg/L; Сo 5 ¸ 350 мg/L; Cr 10 ¸ 100 мg/L; Mn 6 ¸ 250 мg/L; Ni 10 ¸ 350 мg/L; Pb 3 ¸ 240 мg/L; Se 10 ¸ 500 мg/L; Tl 2 ¸ 600 мg/L. Precision (RSD) for the middle of dynamic range ranged from 5% for Mn to 11 for Se.

  10. Determination of cadmium and lead at low levels by using preconcentration at fullerene coupled to thermospray flame furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Pereira, M. G.; Pereira-Filho, E. R.; Berndt, H.; Arruda, M. A. Z.

    2004-04-01

    A new and sensitive method for Cd and Pb determinations, based on the coupling of thermospray flame furnace atomic absorption spectrometry and a preconcentrator system, was developed. The procedure comprised the chelating of Cd and Pb with ammonium pyrrolidinedithiocarbamate with posterior adsorption of the chelates on a mixture (40 mg) of C 60 and C 70 at a flow rate of 2.0 ml min -1. These chelates were eluted from the adsorbent by passing a continuous flow of ethanol (80% v/v) at 0.9 ml min -1 to a nickel tube placed in an air/acetylene flame. After sample introduction into the tube by using a ceramic capillary (0.5 mm i.d.), the analytical signals were registered as peak height. Under these conditions, improvement factors in detectability of 675 and 200 were obtained for Cd and Pb, respectively, when compared to conventional flame atomic absorption spectrometry. Spiked samples (mineral and tap waters) and drinking water containing natural concentrations of Cd were employed for evaluating accuracy by comparing the results obtained from the proposed methodology with those using electrothermal atomic absorption spectrometry. In addition, certified reference materials (rye grass, CRM 281 and pig kidney, CRM 186) were also adopted for the accuracy tests. Due to the good linearity ranges for Cd (0.5-5.0 μg l -1) and Pb (10-250 μg l -1), samples with different concentrations could be analyzed. Detection limits of 0.1 and 2.4 μg l -1 were obtained for Cd and Pb, respectively, and RSD values <4.5% were observed ( n=10). Finally, a sample throughput of 24 determinations per hour was possible.

  11. Determination of sulfur in bovine serum albumin and L-cysteine using high-resolution continuum source molecular absorption spectrometry of the CS molecule

    NASA Astrophysics Data System (ADS)

    Andrade-Carpente, Eva; Peña-Vázquez, Elena; Bermejo-Barrera, Pilar

    2016-08-01

    In this study, the content of sulfur in bovine serum albumin and L-cysteine was determined using high-resolution continuum source molecular absorption spectrometry of the CS molecule, generated in a reducing air-acetylene flame. Flame conditions (height above the burner, measurement time) were optimized using a 3.0% (v/v) sulfuric acid solution. A microwave lab station (Ethos Plus MW) was used for the digestion of both compounds. During the digestion step, sulfur was converted to sulfate previous to the determination. Good repeatability (4-10%) and analytical recovery (91-106%) was obtained.

  12. Determination of antimony, arsenic, bismuth, selenium, tellurium and tin by low pressure atomic absorption spectrometry with a quartz tube furnace atomizer and hydride generation with air addition.

    PubMed

    Zhang, B; Wang, Y; Wang, X; Chen, X; Feng, J

    1995-08-01

    A new method has been developed for the determination of antimony, arsenic, bismuth, selenium, tellurium and tin by hydride generation-atomic absorption spectrometry in an electrically heated quartz tube furnace under sub-atmospheric pressure. The hydride generator, operating at a pressure lower than atmospheric, is used to generate and collect the hydrides of these elements. A certain volume (at atmospheric pressure) of air is then added to the generator after the formation of the volatile hydride. The gaseous mixture of the hydride and air is drawn into an evacuated, heated quartz tube by a vacuum pump. The proposed method gives improved sensitivities and detection limits.

  13. [Determination of Pb and Cd in atomospheric particulates by flame atomic absorption spectrometry coupled with on-line flow injection pretreatment with ultrasonic leaching].

    PubMed

    Gao, Yan; Wang, Dong-hai; Lin, Yu-bin; Li, Jian-yi; Kong, Qing-zhen

    2003-04-01

    In this paper, the method for extracting the metals from the filter membrane of the atomospheric particulates with ultrasonic leaching was reported. The dissolution conditions of kinds and acidity as well as the interference conditions were studied. The method of determination Pb and Cd of the atomospheric particulates by flame atomic absorption spectrometry coupled with on-line flow injection preconcentration was proved to be rapid and accuracy. The recoveries are more than 97%. The relative standard deviation of six samples are less than 2.6%.

  14. Mesoporous Silica Nanoparticles as an Adsorbent for Preconcentration and Determination of Trace Amount of Nickel in Environmental Samples by Atom Trap Flame Atomic Absorption Spectrometry

    NASA Astrophysics Data System (ADS)

    Shirkhanloo, H.; Falahnejad, M.; Zavvar Mousavi, H.

    2016-01-01

    A rapid enrichment method based on solid-phase extraction (SPE) has been established for preconcentration and separation of trace Ni(II) ions in water samples prior to their determination by atom trap flame atomic absorption spectrometry. A column filled with bulky NH2-UVM7 was used as the novel adsorbent. Under optimal conditions, the linear range, limit of detection (LOD), and preconcentration factor (PF) were 3-92 μg/L, 0.8 μg/L, and 100, respectively. The validity of the method was checked by the standard reference material.

  15. Automated continuous monitoring of inorganic and total mercury in wastewater and other waters by flow-injection analysis and cold-vapour atomic absorption spectrometry

    PubMed Central

    Birnie, S. E.

    1988-01-01

    An automated continuous monitoring system for the determination of inorganic and total mercury by flow-injection analysis followed by cold-vapour atomic absorption spectrometry is described. The method uses a typical flow-injection manifold where digestion and reduction of the injected sample takes place. Mercury is removed by aeration from the flowing stream in a specially designed air-liquid separator and swept into a silica cell for absorption measurement at a wavelength of 253.7 nm. A calibration curve up to 10 μg Hg ml-1 using three different path length cells is obtained with a detection limit of 0.02 μg Hg ml-1. The sampling rate of an injection every 3 min produces 20 results per hour from a flowing stream. PMID:18925201

  16. Method development for the determination of bromine in coal using high-resolution continuum source graphite furnace molecular absorption spectrometry and direct solid sample analysis

    NASA Astrophysics Data System (ADS)

    Pereira, Éderson R.; Castilho, Ivan N. B.; Welz, Bernhard; Gois, Jefferson S.; Borges, Daniel L. G.; Carasek, Eduardo; de Andrade, Jailson B.

    2014-06-01

    This work reports a simple approach for Br determination in coal using direct solid sample analysis in a graphite tube furnace and high-resolution continuum source molecular absorption spectrometry. The molecular absorbance of the calcium mono-bromide (CaBr) molecule has been measured using the rotational line at 625.315 nm. Different chemical modifiers (zirconium, ruthenium, palladium and a mixture of palladium and magnesium nitrates) have been evaluated in order to increase the sensitivity of the CaBr absorption, and Zr showed the best overall performance. The pyrolysis and vaporization temperatures were 800 °C and 2200 °C, respectively. Accuracy and precision of the method have been evaluated using certified coal reference materials (BCR 181, BCR 182, NIST 1630a, and NIST 1632b) with good agreement (between 98 and 103%) with the informed values for Br. The detection limit was around 4 ng Br, which corresponds to about 1.5 μg g- 1 Br in coal, based on a sample mass of 3 mg. In addition, the results were in agreement with those obtained using electrothermal vaporization inductively coupled plasma mass spectrometry, based on a Student t-test at a 95% confidence level. A mechanism for the formation of the CaBr molecule is proposed, which might be considered for other diatomic molecules as well.

  17. Evaluation of solid sampling for determination of Mo, Ni, Co, and V in soil by high-resolution continuum source graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Babos, Diego Victor; Barros, Ariane Isis; Ferreira, Edilene Cristina; Neto, José Anchieta Gomes

    2017-04-01

    New methods are proposed for the determination of Mo, Ni, Co, and V in soils using high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling. Cobalt and V were simultaneously determined, and different analytical lines of Ni and V were monitored to adjust sensitivity for each sample. Accuracy was checked by means of soil certified reference materials, and also by flame atomic absorption spectrometry as comparative technique. The results for Mo, Ni, Co, and V found by proposed methods were in agreement with certified values and with those obtained by the comparative technique at 95% confidence level. The concentrations found in different soil samples were in the ranges 0.19-1.84 mg kg- 1 (Mo), 9.2-22.7 mg kg- 1 (Ni), 1.1-10.7 mg kg- 1 (Co), and 35.6-426.1 mg kg- 1 (V). The relative standard deviations were in the ranges 3.2-10% (Mo), 2.8-9.8% (Ni), 4.0-9.2% (Co), and 1.2-8.0% (V). The limits of quantification for Mo, Ni, Co, and V were 0.027, 0.071, 0.15, and 1.43 ng, respectively.

  18. Application of dual-cloud point extraction for the trace levels of copper in serum of different viral hepatitis patients by flame atomic absorption spectrometry: A multivariate study

    NASA Astrophysics Data System (ADS)

    Arain, Salma Aslam; Kazi, Tasneem G.; Afridi, Hassan Imran; Abbasi, Abdul Rasool; Panhwar, Abdul Haleem; Naeemullah; Shanker, Bhawani; Arain, Mohammad Balal

    2014-12-01

    An efficient, innovative preconcentration method, dual-cloud point extraction (d-CPE) has been developed for the extraction and preconcentration of copper (Cu2+) in serum samples of different viral hepatitis patients prior to couple with flame atomic absorption spectrometry (FAAS). The d-CPE procedure was based on forming complexes of elemental ions with complexing reagent 1-(2-pyridylazo)-2-naphthol (PAN), and subsequent entrapping the complexes in nonionic surfactant (Triton X-114). Then the surfactant rich phase containing the metal complexes was treated with aqueous nitric acid solution, and metal ions were back extracted into the aqueous phase, as second cloud point extraction stage, and finally determined by flame atomic absorption spectrometry using conventional nebulization. The multivariate strategy was applied to estimate the optimum values of experimental variables for the recovery of Cu2+ using d-CPE. In optimum experimental conditions, the limit of detection and the enrichment factor were 0.046 μg L-1 and 78, respectively. The validity and accuracy of proposed method were checked by analysis of Cu2+ in certified sample of serum (CRM) by d-CPE and conventional CPE procedure on same CRM. The proposed method was successfully applied to the determination of Cu2+ in serum samples of different viral hepatitis patients and healthy controls.

  19. Application of dual-cloud point extraction for the trace levels of copper in serum of different viral hepatitis patients by flame atomic absorption spectrometry: a multivariate study.

    PubMed

    Arain, Salma Aslam; Kazi, Tasneem G; Afridi, Hassan Imran; Abbasi, Abdul Rasool; Panhwar, Abdul Haleem; Naeemullah; Shanker, Bhawani; Arain, Mohammad Balal

    2014-12-10

    An efficient, innovative preconcentration method, dual-cloud point extraction (d-CPE) has been developed for the extraction and preconcentration of copper (Cu(2+)) in serum samples of different viral hepatitis patients prior to couple with flame atomic absorption spectrometry (FAAS). The d-CPE procedure was based on forming complexes of elemental ions with complexing reagent 1-(2-pyridylazo)-2-naphthol (PAN), and subsequent entrapping the complexes in nonionic surfactant (Triton X-114). Then the surfactant rich phase containing the metal complexes was treated with aqueous nitric acid solution, and metal ions were back extracted into the aqueous phase, as second cloud point extraction stage, and finally determined by flame atomic absorption spectrometry using conventional nebulization. The multivariate strategy was applied to estimate the optimum values of experimental variables for the recovery of Cu(2+) using d-CPE. In optimum experimental conditions, the limit of detection and the enrichment factor were 0.046μgL(-1) and 78, respectively. The validity and accuracy of proposed method were checked by analysis of Cu(2+) in certified sample of serum (CRM) by d-CPE and conventional CPE procedure on same CRM. The proposed method was successfully applied to the determination of Cu(2+) in serum samples of different viral hepatitis patients and healthy controls.

  20. Investigating effects of sample pretreatment on protein stability using size-exclusion chromatography and high-resolution continuum source atomic absorption spectrometry.

    PubMed

    Rakow, Tobias; El Deeb, Sami; Hahne, Thomas; El-Hady, Deia Abd; AlBishri, Hassan M; Wätzig, Hermann

    2014-09-01

    In this study, size-exclusion chromatography and high-resolution atomic absorption spectrometry methods have been developed and evaluated to test the stability of proteins during sample pretreatment. This especially includes different storage conditions but also adsorption before or even during the chromatographic process. For the development of the size exclusion method, a Biosep S3000 5 μm column was used for investigating a series of representative model proteins, namely bovine serum albumin, ovalbumin, monoclonal immunoglobulin G antibody, and myoglobin. Ambient temperature storage was found to be harmful to all model proteins, whereas short-term storage up to 14 days could be done in an ordinary refrigerator. Freezing the protein solutions was always complicated and had to be evaluated for each protein in the corresponding solvent. To keep the proteins in their native state a gentle freezing temperature should be chosen, hence liquid nitrogen should be avoided. Furthermore, a high-resolution continuum source atomic absorption spectrometry method was developed to observe the adsorption of proteins on container material and chromatographic columns. Adsorption to any container led to a sample loss and lowered the recovery rates. During the pretreatment and high-performance size-exclusion chromatography, adsorption caused sample losses of up to 33%.

  1. Determination of lead in blood by chelation with ammonium pyrrolidine dithio-carbamate followed by tungsten-coil atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Salido, Arthur; Sanford, Caryn L.; Jones, Bradley T.

    1999-08-01

    An inexpensive, bench-top blood Pb analyzer has been developed. The system is based on tungsten-coil atomic absorption spectrometry. Pb atomization occurs on W-coils extracted from commercially available slide projector bulbs. The system has minimal power requirements: 120 ACV and 15 A. A small, computer-controlled CCD spectrometer is used as the detector. A Pb hollow cathode lamp is used as the source. Blood Pb is chelated with ammonium pyrrolidine dithio-carbamate and extracted into methyl iso-butyl ketone (4-methyl 2-pentanone). Twenty-microliter volumes of the organic phase are deposited on the W-coil, dried at 1.4 A, charred at 2.3 A and atomized at 6.0 A. Graphite furnace atomic absorption spectrometry is used as a comparison for W-coil results. Levels 1-4 of a NIST standard reference material 955b ‘lead in bovine blood’ are used to test accuracy and precision. The analytical figures of merit for the system are: 12-pg instrument detection limit, 24-pg blood detection limit and a characteristic mass of 28 pg.

  2. Strontium mono-chloride - A new molecule for the determination of chlorine using high-resolution graphite furnace molecular absorption spectrometry and direct solid sample analysis

    NASA Astrophysics Data System (ADS)

    Pereira, Éderson R.; Welz, Bernhard; Lopez, Alfredo H. D.; de Gois, Jefferson S.; Caramori, Giovanni F.; Borges, Daniel L. G.; Carasek, Eduardo; de Andrade, Jailson B.

    2014-12-01

    A new method has been developed for the determination of chlorine in biological reference materials using high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS) of the strontium mono-chloride (SrCl) molecule and direct solid sample analysis. The use of the SrCl molecule for high-temperature MAS was not described up to now in the literature. Preliminary time-dependent density functional theory calculations of the SrCl structure were carried out in order to obtain reasonable estimates of the absorption spectrum of the target molecule. The calculations, which were carried out at BHandHLyp/def2-QZVP level of theory, proved a very accurate and inexpensive way to get information about the spectrum of the SrCl molecule, which enabled us to perform the Cl determination with good sensitivity and specificity. The molecular absorption of the SrCl molecule has been measured using the wavelength at 635.862 nm, and zirconium and palladium have been evaluated as the chemical modifiers in order to increase the sensitivity of the gaseous SrCl molecule generated in the graphite furnace. The pyrolysis and vaporization temperatures were 600 °C and 2300 °C, respectively. Accuracy and precision of the method have been evaluated using biological certified reference materials of both animal and plant origins, showing good agreement with the informed and certified values. Limit of detection and characteristic mass were 1.0 and 2.2 ng, respectively. The results found using HR-CS GF MAS were in agreement (95% confidence level) compared to those obtained by electrothermal vaporization-inductively coupled plasma mass spectrometry.

  3. Determination of phosphorus, sulfur and the halogens using high-temperature molecular absorption spectrometry in flames and furnaces--A review.

    PubMed

    Welz, Bernhard; Lepri, Fábio G; Araujo, Rennan G O; Ferreira, Sérgio L C; Huang, Mao-Dong; Okruss, Michael; Becker-Ross, Helmut

    2009-08-11

    The literature about the investigation of molecular spectra of phosphorus, sulfur and the halogens in flames and furnaces, and the use of these spectra for the determination of these non-metals has been reviewed. Most of the investigations were carried out using conventional atomic absorption spectrometers, and there were in essence two different approaches. In the first one, dual-channel spectrometers with a hydrogen or deuterium lamp were used, applying the two-line method for background correction; in the second one, a line source was used that emitted an atomic line, which overlapped with the molecular spectrum. The first approach had the advantage that any spectral interval could be accessed, but it was susceptible to spectral interference; the second one had the advantage that the conventional background correction systems could be used to minimize spectral interferences, but had the problem that an atomic line had to be found, which was overlapping sufficiently well with the maximum of the molecular absorption spectrum. More recently a variety of molecular absorption spectra were investigated using a low-resolution polychromator with a CCD array detector, but no attempt was made to use this approach for quantitative determination of non-metals. The recent introduction and commercial availability of high-resolution continuum source atomic absorption spectrometers is offering completely new possibilities for molecular absorption spectrometry and its use for the determination of non-metals. The use of a high-intensity continuum source together with a high-resolution spectrometer and a CCD array detector makes possible selecting the optimum wavelength for the determination and to exclude most spectral interferences.

  4. Correlation between the Gas Temperature and the Atomization Behavior of Analyte Elements in Flame Atomic Absorption Spectrometry Estimated with a Continuum-light-source Spectrometer System

    NASA Astrophysics Data System (ADS)

    Toya, Yusuke; Itagaki, Toshiko; Wagatsuma, Kazuaki

    2016-11-01

    In flame atomic absorption spectrometry (FAAS), the gas temperature for two types of the gas compositions, which was estimated based on a two-line method by using a simultaneous multi-wavelength spectrometer, on which a line pair of ruthenium, Ru I 372.692 nm and Ru I 372.803 nm having different excitation energies, was measured at the same time. Also using the spectrometer system, the absorption signals of both iron and ruthenium, whose oxides had different thermodynamic properties: the latter oxide was decomposed much more easily than the former one, were investigated with a nitrous oxide - acetylene flame, in comparison with an air - acetylene flame. The fuel/oxidant ratio of both the flames as well as the height of the optical path was varied as an experimental parameter. The atomization behavior of iron and ruthenium, which could be deduced from a variation in their absorption signals, was considered to be dependent not only on the gas temperature but on reducing atmosphere of the flame gas, which might be attributed to reducing radicals in a fuel-excess flame consisting of nitrous oxide. In the nitrous oxide - acetylene flame, a broader optical path having a constant and higher temperature was obtained, thus contributing to formation of analyte atoms with a stable atomization efficiency and eventually to better precision in the analytical result in FAAS.

  5. Absorption-mode Fourier transform mass spectrometry: the effects of apodization and phasing on modified protein spectra.

    PubMed

    Qi, Yulin; Li, Huilin; Wills, Rebecca H; Perez-Hurtado, Pilar; Yu, Xiang; Kilgour, David P A; Barrow, Mark P; Lin, Cheng; O'Connor, Peter B

    2013-06-01

    The method of phasing broadband Fourier transform ion cyclotron resonance (FT-ICR) spectra allows plotting the spectra in the absorption-mode; this new approach significantly improves the quality of the data at no extra cost. Herein, an internal calibration method for calculating the phase function has been developed and successfully applied to the top-down spectra of modified proteins, where the peak intensities vary by 100×. The result shows that the use of absorption-mode spectra allows more peaks to be discerned within the recorded data, and this can reveal much greater information about the protein and modifications under investigation. In addition, noise and harmonic peaks can be assigned immediately in the absorption-mode.

  6. Direct determination of fluorine in niobium oxide using slurry sampling electrothermal high-resolution continuum source molecular absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Huang, Mao Dong; Becker-Ross, Helmut; Okruss, Michael; Geisler, Sebastian; Florek, Stefan; Richter, Silke; Meckelburg, Angela

    Aiming for a round-robin test, a new method for the direct determination of fluorine in niobium oxide has been developed. It is based on the use of high-resolution molecular absorption spectra of calcium mono-fluoride (CaF) generated in the graphite tube, combined with the slurry sampling technique. The absorption measurement was performed at the 606.44 nm CaF rotational line. By using graphite tubes with zirconium carbide (ZrC) modified platform, the molecular absorption sensitivity of CaF has been improved by a factor of 20, and no additional chemical modifier was necessary. Generally, non-spectral interferences were observed in the presence of HCl, H2SO4, and H3PO4. For HCl, additional spectral interference occurred due to an overlap of the absorption spectra of CaF and CaCl. However, due to the absence of these mentioned substances in the current material, such interferences do not exist for this application. The characteristic mass found for the CaF 606.44 nm line was 0.1 ng; the limit of detection was 5 mg fluorine per kg solid sample (3σ criterion). The results obtained by the method were within the range of certified values. Comparing to the classical method such as the pyrohydrolysis-photometric method, the developed new method showed clear advantages regarding sensitivity and specificity. The time requirement for one sample analysis was strongly shortened from several hours to only some minutes.

  7. Extraction of full absorption peaks in airborne gamma-spectrometry by filtering techniques coupled with a study of the derivatives. Comparison with the window method.

    PubMed

    Guillot, L

    2001-01-01

    In this paper, an adaptation of a spectral profile analysis method, currently used in high-resolution spectrometry, to airborne gamma measurements is presented. A new algorithm has been developed for extraction of full absorption peaks by studying the variations in the spectral profile of data recorded with large-volume NaI detectors (16 l) with a short sampling time (2 s). The use of digital filters, taking into consideration the characteristics of the absorption peaks, significantly reduced the counting fluctuations, making detection possible based on study of the first and second derivatives. The absorption peaks are then obtained by modelling, followed by subtraction of the Compton continuum in the detection window. Compared to the conventional stripping ratio method, spectral profile analysis offers similar performance for the natural radioelements. The 137Cs 1SD detection limit is approximately 1200 Bq/m2 in a natural background of 200 Bq/kg 40K, 33 Bq/kg 238U and 33 Bq/kg 232Th. At low energy the very high continuum leads to detection limits similar to those obtained by the windows method, but the results obtained are more reliable. In the presence of peak overlaps, however, analysis of the spectral profile alone is not sufficient to separate the peaks, and further processing is necessary. Within the framework of environmental monitoring studies, spectral profile analysis is of great interest because it does not require any assumptions about the nature of the nuclides. The calculation of the concentrations from the results obtained is simple and reliable, since only the full absorption contributions are taken into consideration. A quantitative estimate of radioactive anomalies can thus be obtained rapidly.

  8. Determination of iodine via the spectrum of barium mono-iodide using high-resolution continuum source molecular absorption spectrometry in a graphite furnace

    NASA Astrophysics Data System (ADS)

    Huang, Mao Dong; Becker-Ross, Helmut; Florek, Stefan; Okruss, Michael; Welz, Bernhard; Morés, Silvane

    2009-07-01

    Molecular absorption spectra of the diatomic molecules AlI, GaI, InI, TlI, MgI, CaI, SrI and BaI, generated in a graphite furnace, were studied using a high-resolution echelle spectrometer with the aim of finding a simple, reliable and sensitive analytical method for the determination of iodine. Among them, the barium mono-iodide (BaI) was found to have the strongest absorption bands around 538 nm and 560 nm, each of them consisting of a series of well-resolved rotational lines with half-widths of about 40-50 pm. The strongest BaI line, the band head at 538.308 nm has been evaluated systematically for its analytical use for the determination of iodine. High concentrations of hydrochloric acid (or chloride), hydrofluoric acid (or fluoride), iron, potassium and sodium resulted in significant reduction of the BaI molecular absorption. Apart from this, no other serious spectral or non-spectral interference has been observed. Different chemical forms of iodine, such as iodide, iodate and organically bound iodine produced identical BaI absorption sensitivity. The detection limit for iodine was 600 pg, and the calibration curve was linear up to 250 ng iodine. Two real samples with different chemical forms of iodine were analyzed using the proposed method. One sample was an iodide pill with a specified iodide content of 200 mg, the other one was a thyroid hormone pill with a specified content of 63.5 mg. The results were in good or satisfactory agreement with those of independent methods, the potentiometric titration and the inductively coupled plasma time-of-flight mass spectrometry (ICP-ToF-MS); the deviations were 2% and 8% for the iodide and the thyroid hormone sample, respectively. The relative standard deviation of the analytical results ( n = 3) was below 2%.

  9. Investigation of Pb species in soils, celery and duckweed by synchrotron radiation X-ray absorption near-edge structure spectrometry

    NASA Astrophysics Data System (ADS)

    Luo, Liqiang; Shen, Yating; Liu, Jian; Zeng, Yuan

    2016-08-01

    The Pb species play a key role in its translocation in biogeochemical cycles. Soils, sediments and plants were collected from farmlands around Pb mines, and the Pb species in them was identified by X-ray absorption near-edge structure spectrometry. In soils, Pb5(PO4)3Cl and Pb3(PO4)2 were detected, and in sediments, Pb-fulvic acids (FAs) complex was identified. A Pb complex with FA fragments was also detected in celery samples. We found that (1) different Pb species were present in soils and sediments; (2) the Pb species in celery, which was grown in sediments, was different from the species present in duckweed, which grew in water; and (3) a Pb-FA-like compound was present in celery roots. The newly identified Pb species, the Pb-FA-like compound, may play a key role in Pb tolerance and translocation within plants.

  10. A simple and fast ultrasound-assisted extraction procedure for Fe and Zn determination in milk-based infant formulas using flame atomic absorption spectrometry (FAAS).

    PubMed

    Machado, Ignacio; Bergmann, Gabriela; Pistón, Mariela

    2016-03-01

    A simple and fast ultrasound-assisted procedure for the determination of iron and zinc in infant formulas is presented. The analytical determinations were carried out by flame atomic absorption spectrometry. Multivariate experiments were performed for optimization; in addition, a comparative study was carried out using two ultrasonic devices. A method using an ultrasonic bath was selected because several samples can be prepared simultaneously, and there is less contamination risk. Analytical precision (sr(%)) was 3.3% and 4.1% for iron and zinc, respectively. Trueness was assessed using a reference material and by comparison of the results obtained analyzing commercial samples using a reference method. The results were statistically equivalent to the certified values and in good agreement with those obtained using the reference method. The proposed method can be easily implemented in laboratories for routine analysis with the advantage of being rapid and in agreement with green chemistry.

  11. A fast and accurate microwave-assisted digestion method for arsenic determination in complex mining residues by flame atomic absorption spectrometry.

    PubMed

    Pantuzzo, Fernando L; Silva, Julio César J; Ciminelli, Virginia S T

    2009-09-15

    A fast and accurate microwave-assisted digestion method for arsenic determination by flame atomic absorption spectrometry (FAAS) in typical, complex residues from gold mining is presented. Three digestion methods were evaluated: an open vessel digestion using a mixture of HCl:HNO(3):HF acids (Method A) and two microwave digestion methods using a mixture of HCl:H(2)O(2):HNO(3) in high (Method B) and medium-pressure (Method C) vessels. The matrix effect was also investigated. Arsenic concentration from external and standard addition calibration curves (at a 95% confidence level) were statistically equal (p-value=0.122) using microwave digestion in high-pressure vessel. The results from the open vessel digestion were statistically different (p-value=0.007) whereas in the microwave digestion in medium-pressure vessel (Method C) the dissolution of the samples was incomplete.

  12. Validation of a hydride generation atomic absorption spectrometry methodology for determination of mercury in fish designed for application in the Brazilian national residue control plan.

    PubMed

    Damin, Isabel C F; Santo, Maria A E; Hennigen, Rosmari; Vargas, Denise M

    2013-01-01

    In the present study, a method for the determination of mercury (Hg) in fish was validated according to ISO/IEC 17025, INMETRO (Brazil), and more recent European recommendations (Commission Decision 2007/333/EC and 2002/657/EC) for implementation in the Brazilian Residue Control Plan (NRCP) in routine applications. The parameters evaluated in the validation were investigated in detail. The results obtained for limit of detection and quantification were respectively, 2.36 and 7.88 μg kg(-1) of Hg. While the recovery varies between 90-96%. The coefficient of variation was of 4.06-8.94% for the repeatability. Furthermore, a comparison using an external proficiency testing scheme was realized. The results of method validated for the determination of the mercury in fish by Hydride generation atomic absorption spectrometry were considered suitable for implementation in routine analysis.

  13. Temperature-controlled electrothermal atomization-atomic absorption spectrometry using a pyrometric feedback system in conjunction with a background monitoring device

    NASA Astrophysics Data System (ADS)

    Van Deijck, W.; Roelofsen, A. M.; Pieters, H. J.; Herber, R. F. M.

    The construction of a temperature-controlled feedback system for electrothermal atomization-atomic absorption spectrometry (ETA-AAS) using an optical pyrometer applied to the atomization stage is described. The system was used in conjunction with a fast-response background monitoring device. The heating rate of the furnace amounted to 1400° s -1 with a reproducibility better than 1%. The precision of the temperature control at a steady state temperature of 2000°C was 0.1%. The analytical improvements offered by the present system have been demonstrated by the determination of cadmium and lead in blood and finally by the determination of lead in serum. Both the sensitivity and the precision of the method have been improved. The accuracy of the method was checked by determining the lead content for a number of scrum samples both by ETA-AAS and differential pulse anodic stripping voltametry (DPASV) and proved to be satisfactory.

  14. Evaluation of cadmium in greenhouse soils and agricultural products of Jiroft (Iran) using microwave digestion prior to atomic absorption spectrometry determination.

    PubMed

    Afzali, Daryoush; Fathirad, Fariba; Afzali, Zahra; Majdzadeh-Kermani, Seyed Mohammad Javad

    2015-03-01

    This study determines total levels of potentially toxic trace element, Cd (II) in Jiroft (Kerman, Iran) greenhouse soil and agricultural products that are grown in these greenhouses (tomatoes and cucumbers), and the comparison with soil outside of greenhouse using microwave digestion prior to flame atomic absorption spectrometry determination. The results show that the cadmium concentration in greenhouse soil is 0.9-1.9 mg kg(-1) and out of greenhouse is 0.4-1.0 mg kg(-1). Also, cadmium concentration range in tomatoes and cucumbers is about 0.07-0.40 mg kg(-1). The obtained results show that the concentration of this metal in greenhouse soil is higher than outside soil samples and is below the safe limit.

  15. Application of High Resolution-Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS): determination of trace elements in tea and tisanes.

    PubMed

    Paz-Rodríguez, Beatriz; Domínguez-González, María Raquel; Aboal-Somoza, Manuel; Bermejo-Barrera, Pilar

    2015-03-01

    A new application of HR-CS FAAS (High Resolution-Continuum Source Flame Atomic Absorption Spectrometry) has been developed for the determination of several trace elements (Ca, Co, Cu, Fe, Mn, Ni, Na and Zn) in infusions made from tea, rooibos and tea with seaweed samples. The proposed methods are fast, inexpensive and show good performances: the mean analytical recovery was approximately 100%. The mean limit of detection was 29.4 μg/l, and the mean limit of quantification was 98.0 μg/l (both limits refer to the brewed samples). Due to the matrix effect observed, the standard addition method had to be applied. Preliminary classification (based on metal contents) using chemometric techniques such as PCA (Principal Component Analysis) and CA (Cluster Analysis), was successful for infusions made from rooibos and tea with seaweed, but inconclusive for black and green teas.

  16. Direct determination of Pb in raw milk by graphite furnace atomic absorption spectrometry (GF AAS) with electrothermal atomization sampling from slurries.

    PubMed

    de Oliveira, Tatiane Milão; Augusto Peres, Jayme; Lurdes Felsner, Maria; Cristiane Justi, Karin

    2017-08-15

    Milk is an important food in the human diet due to its physico-chemical composition; therefore, it is necessary to monitor contamination by toxic metals such as Pb. Milk sample slurries were prepared using Triton X-100 and nitric acid for direct analysis of Pb using graphite furnace atomic absorption spectrometry - GF AAS. After dilution of the slurries, 10.00µl were directly introduced into the pyrolytic graphite tube without use of a chemical modifier, which acts as an advantage considering this type of matrix. The limits of detection and quantification were 0.64 and 2.14µgl(-1), respectively. The figures of merit studied showed that the proposed methodology without pretreatment of the raw milk sample and using external standard calibration is suitable. The methodology was applied in milk samples from the Guarapuava region, in Paraná State (Brazil) and Pb concentrations ranged from 2.12 to 37.36µgl(-1).

  17. Effects of iron concentration level in extracting solutions from contaminated soils on the determination of zinc by flame atomic absorption spectrometry with two background correctors.

    PubMed

    Waterlot, Christophe; Pelfrêne, Aurélie; Douay, Francis

    2012-01-01

    Zinc and iron concentrations were determined after digestion, water, and three-step sequential extractions of contaminated soils. Analyses were carried out using flame absorption spectrometry with two background correctors: a deuterium lamp used as the continuum light source (D(2) method) and the high-speed self-reversal method (HSSR method). Regarding the preliminary results obtained with synthetic solutions, the D(2) method often emerged as an unsuitable configuration for compensating iron spectral interferences. In contrast, the HSSR method appeared as a convenient and powerful configuration and was tested for the determination of zinc in contaminated soils containing high amounts of iron. Simple, fast, and interference-free method, the HSSR method allows zinc determination at the ppb level in the presence of large amounts of iron with high stability, sensitivity, and reproducibility of results. Therefore, the HSSR method is described here as a promising approach for monitoring zinc concentrations in various iron-containing samples without any pretreatment.

  18. Slurry sampling for direct analysis of solid materials by electrothermal atomic absorption spectrometry (ETAAS). A literature review from 1990 to 2000.

    PubMed

    Cal-Prieto, M J; Felipe-Sotelo, M; Carlosena, A; Andrade, J M; López-Mahía, P; Muniategui, S; Prada, D

    2002-01-04

    The determination of trace metals in solid samples has traditionally been performed by acid digestion and subsequent measurement by a suitable instrumental technique. This dissolution step is time-consuming and it shows important drawbacks. For these reasons, in the past years many efforts have been focused on the direct analysis of solid samples. Among the developed methodologies, slurry sampling-electrothermal atomic absorption spectrometry combines the significant advantages of the solid and liquid sampling methods, and it can be already considered as a mature technique, that is widely utilized for metal determination in both organic and inorganic matrices, even for routine analysis. Accordingly, this work gives a retrospective view of the progresses of this technique during the past decade (1990-2000).

  19. Optimization of microwave assisted digestion procedure for the determination of zinc, copper and nickel in tea samples employing flame atomic absorption spectrometry.

    PubMed

    Soylak, Mustafa; Tuzen, Mustafa; Souza, Anderson Santos; das Graças Andrade Korn, Maria; Ferreira, Sérgio Luis Costa

    2007-10-22

    The present paper describes the development of a microwave assisted digestion procedure for the determination of zinc, copper and nickel in tea samples employing flame atomic absorption spectrometry (FAAS). The optimization step was performed using a full factorial design (2(3)) involving the factors: composition of the acid mixture (CMA), microwave power (MP) and radiation time (RT). The experiments of this factorial were carried out using a certified reference material of tea GBW 07605 furnished by National Research Centre for Certified Reference Materials, China, being the metal recoveries considered as response. The relative standard deviations of the method were found below 8% for the three elements. The procedure proposed was used for the determination of copper, zinc and nickel in several samples of tea from Turkey. For 10 tea samples analyzed, the concentration achieved for copper, zinc and nickel varied at 6.4-13.1, 7.0-16.5 and 3.1-5.7 (microg g(-1)), respectively.

  20. Solvent microextraction-flame atomic absorption spectrometry (SME-FAAS) for determination of ultratrace amounts of cadmium in meat and fish samples.

    PubMed

    Goudarzi, Nasser

    2009-02-11

    A simple, low cost and highly sensitive method based on solvent microextraction (SME) for separation/preconcentration and flame atomic absorption spectrometry (FAAS) was proposed for the determination of ultratrace amounts of cadmium in meat and fish samples. The analytical procedure involved the formation of a hydrophobic complex by mixing the analyte solution with an ammonium pyrrolidinedithiocarbamate (APDC) solution. In suitable conditions, the complex of cadmium-APDC entered the micro organic phase, and thus, separation of the analyte from the matrix was achieved. Under optimal chemical and instrumental conditions, a detection limit (3 sigma) of 0.8 ng L(-1) and an enrichment factor of 93 were achieved. The relative standard deviation for the method was found to be 2.2% for Cd. The interference effects of some anions and cations were also investigated. The developed method has been applied to the determination of trace Cd in meat and fish samples.

  1. Chemometric evaluation of Cd, Co, Cr, Cu, Ni (inductively coupled plasma optical emission spectrometry) and Pb (graphite furnace atomic absorption spectrometry) concentrations in lipstick samples intended to be used by adults and children.

    PubMed

    Batista, Érica Ferreira; Augusto, Amanda dos Santos; Pereira-Filho, Edenir Rodrigues

    2016-04-01

    A method was developed for determining the concentrations of Cd, Co, Cr, Cu, Ni and Pb in lipstick samples intended to be used by adults and children using inductively coupled plasma optical emission spectrometry (ICP OES) and graphite furnace atomic absorption spectrometry (GF AAS) after treatment with dilute HNO3 and hot block. The combination of fractional factorial design and Desirability function was used to evaluate the ICP OES operational parameters and the regression models using Central Composite and Doehlert designs were calculated to stablish the best working condition for all analytes. Seventeen lipstick samples manufactured in different countries with different colors and brands were analyzed. Some samples contained high concentrations of toxic elements, such as Cr and Pb, which are carcinogenic and cause allergic and eczematous dermatitis. The maximum concentration detected was higher than the permissible safe limits for human use, and the samples containing these high metal concentrations were intended for use by children. Principal component analysis (PCA) was used as a chemometrics tool for exploratory analysis to observe the similarities between samples relative to the metal concentrations (a correlation between Cd and Pb was observed).

  2. Assessment of the Halogen Content of Brazilian Inhalable Particulate Matter (PM10) Using High Resolution Molecular Absorption Spectrometry and Electrothermal Vaporization Inductively Coupled Plasma Mass Spectrometry, with Direct Solid Sample Analysis.

    PubMed

    de Gois, Jefferson S; Almeida, Tarcisio S; Alves, Jeferson C; Araujo, Rennan G O; Borges, Daniel L G

    2016-03-15

    Halogens in the atmosphere play an important role in climate change and also represent a potential health hazard. However, quantification of halogens is not a trivial task, and methods that require minimum sample preparation are interesting alternatives. Hence, the aim of this work was to evaluate the feasibility of direct solid sample analysis using high-resolution continuum source molecular absorption spectrometry (HR-CS MAS) for F determination and electrothermal vaporization-inductively coupled plasma mass spectrometry (ETV-ICP-MS) for simultaneous Cl, Br, and I determination in airborne inhalable particulate matter (PM10) collected in the metropolitan area of Aracaju, Sergipe, Brazil. Analysis using HR-CS MAS was accomplished by monitoring the CaF molecule, which was generated at high temperatures in the graphite furnace after the addition of Ca. Analysis using ETV-ICP-MS was carried out using Ca as chemical modifier/aerosol carrier in order to avoid losses of Cl, Br, and I during the pyrolysis step, with concomitant use of Pd as a permanent modifier. The direct analysis approach resulted in LODs that were proven adequate for halogen determination in PM10, using either standard addition calibration or calibration against a certified reference material. The method allowed the quantification of the halogens in 14 PM10 samples collected in a northeastern coastal city in Brazil. The results demonstrated variations of halogen content according to meteorological conditions, particularly related to rainfall, humidity, and sunlight irradiation.

  3. Quantification of absorption, retention and elimination of two different oral doses of vitamin A in Zambian boys using accelerator mass spectrometry

    SciTech Connect

    Aklamati, E K; Mulenga, M; Dueker, S R; Buchholz, B A; Peerson, J M; Kafwembe, E; Brown, K H; Haskell, M J

    2009-10-12

    A recent survey indicated that high-dose vitamin A supplements (HD-VAS) had no apparent effect on vitamin A (VA) status of Zambian children <5 y of age. To explore possible reasons for the lack of response to HD-VAS among Zambian children, we quantified the absorption, retention, and urinary elimination of either a single HDVAS (60 mg) or a smaller dose of stable isotope (SI)-labeled VA (5 mg), which was used to estimate VA pool size, in 3-4 y old Zambian boys (n = 4 for each VA dose). A 25 nCi tracer dose of [{sup 14}C{sub 2}]-labeled VA was co-administered with the HD-VAS or SI-labeled VA, and 24-hr stool and urine samples were collected for 3 and 7 consecutive days, respectively, and 24-hr urine samples at 4 later time points. Accelerator Mass Spectrometry (AMS) was used to measure the cumulative excretion of {sup 14}C in stool and urine 3d after dosing to estimate, respectively, absorption and retention of the VAS and SI-labeled VA. The urinary elimination rate (UER) was estimated by plotting {sup 14}C in urine vs. time, and fitting an exponential equation to the data. Estimates of mean absorption, retention and the UER were 83.8 {+-} 7.1%, 76.3 {+-} 6.7%, and 1.9 {+-} 0.6%/d, respectively, for the HD-VAS and 76.5 {+-} 9.5%, 71.1 {+-} 9.4%, and 1.8 {+-} 1.2%/d, respectively for the smaller dose of SI-labeled VA. Estimates of absorption, retention and the UER did not differ by size of the VA dose administered (P=0.26, 0.40, 0.88, respectively). Estimated absorption and retention were negatively associated with reported fever (P=0.011) and malaria (P =0.010). HD-VAS and SI-labeled VA were adequately absorbed, retained and utilized in apparently healthy Zambian preschool-age boys, although absorption and retention may be affected by recent infections.

  4. Determination of trace amount of cadmium using dispersive liquid-liquid microextraction-slotted quartz tube-flame atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Fırat, Merve; Bakırdere, Sezgin; Fındıkoğlu, Maral Selin; Kafa, Emine Betül; Yazıcı, Elif; Yolcu, Melda; Büyükpınar, Çağdaş; Chormey, Dotse Selali; Sel, Sabriye; Turak, Fatma

    2017-03-01

    This study was performed to develop a sensitive analytical method for the determination of cadmium by slotted quartz tube-flame atomic absorption spectrometry (SQT-FAAS) after dispersive liquid-liquid microextraction (DLLME). The parameters affecting the cadmium complex formation and its extraction output were optimized to obtain high extraction efficiency. These included the pH and amount of the buffer solution, and the concentration of the ligand. The DLLME method was comprehensively optimized based on the type and amount of extraction solvent, dispersive solvent and salt. The type and period of mixing needed for a more effective extraction was also investigated. In order to further improve the sensitivity for the determination of cadmium, the flame atomic absorption spectrometry was fitted with a slotted quartz tube to increase the residence time of cadmium atoms in the pathway of incident light from a hollow cathode lamp. The limits of detection and quantitation (LOD and LOQ) for the FAAS were found to be 42 and 140 μg L- 1, respectively. Under the optimum conditions, LOD and LOQ of the FAAS after DLLME were calculated as 1.3 and 4.4 μg L- 1, respectively. Combining both optimized parameters of the DLLME and SQT-FAAS gave 0.5 and 1.5 μg L- 1 as LOD and LOQ, respectively. Accuracy of the method was also checked using a wastewater certified reference material (EU-L-2), and the result was in good agreement with the certified value.

  5. Multiwalled carbon nanotubes as a sorbent material for the solid phase extraction of lead from urine and subsequent determination by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Peña Crecente, Rosa M.; Lovera, Carlha Gutiérrez; García, Julia Barciela; Méndez, Jennifer Álvarez; Martín, Sagrario García; Latorre, Carlos Herrero

    2014-11-01

    The determination of lead in urine is a way of monitoring the chemical exposure to this metal. In the present paper, a new method for the Pb determination by electrothermal atomic absorption spectrometry (ETAAS) in urine at low levels has been developed. Lead was separated from the undesirable urine matrix by means of a solid phase extraction (SPE) procedure. Oxidized multiwalled carbon nanotubes have been used as a sorbent material. Lead from urine was retained at pH 4.0 and was quantitatively eluted using a 0.7 M nitric acid solution and was subsequently measured by ETAAS. The effects of parameters that influence the adsorption-elution process (such as pH, eluent volume and concentration, sampling and elution flow rates) and the atomic spectrometry conditions have been studied by means of different factorial design strategies. Under the optimized conditions, the detection and quantification limits obtained were 0.08 and 0.26 μg Pb L- 1, respectively. The results demonstrate the absence of a urine matrix effect and this is the consequence of the SPE process carried out. Therefore, the developed method is useful for the analysis of Pb at low levels in real samples without the influence of other urine components. The proposed method was applied to the determination of lead in urine samples of unexposed healthy people and satisfactory results were obtained (in the range 3.64-22.9 μg Pb L- 1).

  6. Evaluation of the memory effect on gold-coated silica adsorption tubes used for the analysis of gaseous mercury by cold vapor atomic absorption spectrometry.

    PubMed

    Rahman, Mohammad Mahmudur; Brown, Richard J C; Kim, Ki-Hyun; Yoon, Hye-On; Phan, Nhu-Thuc

    2013-01-01

    In an effort to reduce the experimental bias involved in the analysis of gaseous elemental mercury (Hg(o)), the blank response from gold-coated adsorption tubes has been investigated using cold vapor atomic absorption spectrometry (CVAAS). Our study has been compared with our recent investigation on memory effect in a cold vapour atomic fluorescence spectrometry (CVAFS). The pattern of blank responses was quantified after loading different amounts of mercury and after different time intervals of 1, 14, and 45 days. In case of the one day interval, the result of five to six instant blank heating cycles confirmed successful liberation of mercury following the second and third blank heating cycles. The results of 14 or 45 days generally suggest that liberation of excess mercury is affected by both the initial loading amount and the length of storage time prior to analysis. We have demonstrated a possibly effective way to reduce memory effects. Some similarities of these results with those from CVAFS experiment suggests that the blank response is caused by a combination of mercury absorbed within the bulk gold and micro- and nanoparticles liberated during heating and not from coabsorbing interfering gaseous species.

  7. Feasibility of dispersive liquid-liquid microextraction for extraction and preconcentration of Cu and Fe in red and white wine and determination by flame atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Seeger, Tassia S.; Rosa, Francisco C.; Bizzi, Cezar A.; Dressler, Valderi L.; Flores, Erico M. M.; Duarte, Fabio A.

    2015-03-01

    A method for extraction and preconcentration of Cu and Fe in red and white wines using dispersive liquid-liquid microextraction (DLLME) and determination by flame atomic absorption spectrometry (F AAS) was developed. Extraction was performed using sodium diethyldithiocarbamate as chelating agent and a mixture of 40 μL of 1,2-dichlorobenzene (extraction solvent) and 900 μL of methanol (dispersive solvent). Some parameters that influencing the extraction efficiency such as pH (2 to 5), concentration of chelating agent (0 to 2%), effect of salt addition (0 to 10%), number of washing steps (1 to 4) and centrifugation time (0 to 15 min) were studied. Accuracy was evaluated after microwave-assisted digestion in closed vessels and analytes were determined by inductively coupled plasma optical emission spectrometry. Agreement with the proposed method ranged from 91 to 110 and from 89 to 113% for Cu and Fe, respectively. Calibration of F AAS instrument was performed using analyte addition method and limits of detection were 6.3 and 2.4 μg L- 1 for Cu and Fe, respectively. The proposed method was applied for the determination of Cu and Fe in five samples of red wine and three samples of white wine, with concentration ranging from 21 to 178 μg L- 1 and from 1.38 to 3.74 mg L- 1, respectively.

  8. A simple and fast method for assessment of the nitrogen-phosphorus-potassium rating of fertilizers using high-resolution continuum source atomic and molecular absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Bechlin, Marcos André; Fortunato, Felipe Manfroi; da Silva, Ricardo Moutinho; Ferreira, Edilene Cristina; Gomes Neto, José Anchieta

    2014-11-01

    The determination of N, P, and K in fertilizers by high-resolution continuum source flame atomic and molecular absorption spectrometry is proposed. Under optimized conditions, measurements of the diatomic molecules NO and PO at 215.360 and 247.620 nm, respectively, and K using the wing of the alternative line at 404.722 nm allowed calibration curves to be constructed in the ranges 500-5000 mg L- 1 N (r = 0.9994), 100-2000 mg L- 1 P (r = 0.9946), and 100-2500 mg L- 1 K (r = 0.9995). Commercial fertilizers were analyzed by the proposed method and the concentrations of N, P, and K were found to be in agreement with those obtained by Kjeldahl, spectrophotometric, and flame atomic emission spectrometry methods, respectively, at a 95% confidence level (paired t-test). A phosphate rock certified reference material (CRM) was analyzed and the results for P and K were in agreement with the reference values. Recoveries from spiked CRM were in the ranges 97-105% (NO3--N), 95-103% (NH4+-N), 93-103% (urea-N), 99-108% (P), and 99-102% (K). The relative standard deviations (n = 12) for N, P, and K were 6, 4, and 2%, respectively.

  9. Evaluation of the Memory Effect on Gold-Coated Silica Adsorption Tubes Used for the Analysis of Gaseous Mercury by Cold Vapor Atomic Absorption Spectrometry

    PubMed Central

    Rahman, Mohammad Mahmudur; Brown, Richard J. C.; Yoon, Hye-On; Phan, Nhu-Thuc

    2013-01-01

    In an effort to reduce the experimental bias involved in the analysis of gaseous elemental mercury (Hgo), the blank response from gold-coated adsorption tubes has been investigated using cold vapor atomic absorption spectrometry (CVAAS). Our study has been compared with our recent investigation on memory effect in a cold vapour atomic fluorescence spectrometry (CVAFS). The pattern of blank responses was quantified after loading different amounts of mercury and after different time intervals of 1, 14, and 45 days. In case of the one day interval, the result of five to six instant blank heating cycles confirmed successful liberation of mercury following the second and third blank heating cycles. The results of 14 or 45 days generally suggest that liberation of excess mercury is affected by both the initial loading amount and the length of storage time prior to analysis. We have demonstrated a possibly effective way to reduce memory effects. Some similarities of these results with those from CVAFS experiment suggests that the blank response is caused by a combination of mercury absorbed within the bulk gold and micro- and nanoparticles liberated during heating and not from coabsorbing interfering gaseous species. PMID:23589708

  10. Methylmercury determination using a hyphenated high performance liquid chromatography ultraviolet cold vapor multipath atomic absorption spectrometry system

    NASA Astrophysics Data System (ADS)

    Campos, Reinaldo C.; Gonçalves, Rodrigo A.; Brandão, Geisamanda P.; Azevedo, Marlo S.; Oliveira, Fabiana; Wasserman, Julio

    2009-06-01

    The present work investigates the use of a multipath cell atomic absorption mercury detector for mercury speciation analysis in a hyphenated high performance liquid chromatography assembly. The multipath absorption cell multiplies the optical path while energy losses are compensated by a very intense primary source. Zeeman-effect background correction compensates for non-specific absorption. For the separation step, the mobile phase consisted in a 0.010% m/v mercaptoethanol solution in 5% methanol (pH = 5), a C 18 column was used as stationary phase, and post column treatment was performed by UV irradiation (60 °C, 13 W). The eluate was then merged with 3 mol L - 1 HCl, reduction was performed by a NaBH 4 solution, and the Hg vapor formed was separated at the gas-liquid separator and carried through a desiccant membrane to the detector. The detector was easily attached to the system, since an external gas flow to the gas-liquid separator was provided. A multivariate approach was used to optimize the procedure and peak area was used for measurement. Instrumental limits of detection of 0.05 µg L - 1 were obtained for ionic (Hg 2+) and HgCH 3+, for an injection volume of 200 µL. The multipath atomic absorption spectrometer proved to be a competitive mercury detector in hyphenated systems in relation to the most commonly used atomic fluorescence and inductively coupled plasma mass spectrometric detectors. Preliminary application studies were performed for the determination of methyl mercury in sediments.

  11. Use of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS) for Sequential Multi-Element Determination of Metals in Seawater and Wastewater Samples

    NASA Astrophysics Data System (ADS)

    Peña-Vázquez, E.; Barciela-Alonso, M. C.; Pita-Calvo, C.; Domínguez-González, R.; Bermejo-Barrera, P.

    2015-09-01

    The objective of this work is to develop a method for the determination of metals in saline matrices using high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Module SFS 6 for sample injection was used in the manual mode, and flame operating conditions were selected. The main absorption lines were used for all the elements, and the number of selected analytical pixels were 5 (CP±2) for Cd, Cu, Fe, Ni, Pb and Zn, and 3 pixels for Mn (CP±1). Samples were acidified (0.5% (v/v) nitric acid), and the standard addition method was used for the sequential determination of the analytes in diluted samples (1:2). The method showed good precision (RSD(%) < 4%, except for Pb (6.5%)) and good recoveries. Accuracy was checked after the analysis of an SPS-WW2 wastewater reference material diluted with synthetic seawater (dilution 1:2), showing a good agreement between certified and experimental results.

  12. Determination of mercury in airborne particulate matter collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling

    NASA Astrophysics Data System (ADS)

    Araujo, Rennan G. O.; Vignola, Fabíola; Castilho, Ivan N. B.; Borges, Daniel L. G.; Welz, Bernhard; Vale, Maria Goreti R.; Smichowski, Patricia; Ferreira, Sérgio L. C.; Becker-Ross, Helmut

    2011-05-01

    A study has been undertaken to assess the capability of high-resolution continuum source graphite furnace atomic absorption spectrometry for the determination of mercury in airborne particulate matter (APM) collected on glass fiber filters using direct solid sampling. The main Hg absorption line at 253.652 nm was used for all determinations. The certified reference material NIST SRM 1648 (Urban Particulate Matter) was used to check the accuracy of the method, and good agreement was obtained between published and determined values. The characteristic mass was 22 pg Hg. The limit of detection (3σ), based on ten atomizations of an unexposed filter, was 40 ng g - 1 , corresponding to 0.12 ng m - 3 in the air for a typical air volume of 1440 m 3 collected within 24 h. The limit of quantification was 150 ng g -1, equivalent to 0.41 ng m -3 in the air. The repeatability of measurements was better than 17% RSD (n = 5). Mercury concentrations found in filter samples loaded with APM collected in Buenos Aires, Argentina, were between < 40 ng g -1 and 381 ± 24 ng g -1. These values correspond to a mercury concentration in the air between < 0.12 ng m -3 and 1.47 ± 0.09 ng m -3. The proposed procedure was found to be simple, fast and reliable, and suitable as a screening procedure for the determination of mercury in APM samples.

  13. Determination of phospholipids in soybean lecithin samples via the phosphorus monoxide molecule by high-resolution continuum source graphite furnace molecular absorption spectrometry.

    PubMed

    Pires, Laís N; Brandão, Geovani C; Teixeira, Leonardo S G

    2017-06-15

    This paper presents a method for determining phospholipids in soybean lecithin samples by phosphorus determination using high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS) via molecular absorption of phosphorus monoxide. Samples were diluted in methyl isobutyl ketone. The best conditions were found to be 213.561nm with a pyrolysis temperature of 1300°C, a volatilization temperature of 2300°C and Mg as a chemical modifier. To increase the analytical sensitivity, measurement of the absorbance signal was obtained by summing molecular transition lines for PO surrounding 213nm: 213.561, 213.526, 213.617 and 213.637nm. The limit of detection was 2.35mgg(-1) and the precision, evaluated as relative standard deviation (RSD), was 2.47% (n=10) for a sample containing 2.2% (w/v) phosphorus. The developed method was applied for the analysis of commercial samples of soybean lecithin. The determined concentrations of phospholipids in the samples varied between 38.1 and 45% (w/v).

  14. Solid sampling determination of total fluorine in baby food samples by high-resolution continuum source graphite furnace molecular absorption spectrometry.

    PubMed

    Ozbek, Nil; Akman, Suleyman

    2016-11-15

    This study describes the applicability of solid sampling technique for the determination of fluorine in various baby foods via molecular absorption of calcium monofluoride generated in a graphite furnace of high-resolution continuum source atomic absorption spectrometry. Fluorine was determined at CaF wavelength, 606.440nm in a graphite tube applying a pyrolysis temperature of 1000°C and a molecule forming temperature of 2200°C. The limit of detection and characteristic mass of the method were 0.20ng and 0.17ng of fluorine, respectively. The fluorine concentrations determined in standard reference sample (bush branches and leaves) were in good agreement with the certified values. By applying the optimized parameters, the concentration of fluorine in various baby foods were determined. The fluorine concentrations were ranged from

  15. Speciation analysis and the assessment of bioavailability of manganese in phytomedicines by extraction with octanol and determination by flame atomic absorption spectrometry.

    PubMed

    Li, Shun-xing; Zheng, Feng-ying; Liu, Xian-li; Cai, Wen-Lian

    2005-01-01

    Trace elements in phytomedicines are present in the form of metallic complexes. Since n-octanol, a long-chain alkanol, presents a configuration similar to that of carbohydrates and lipids, the lipophilicity and absorptivity of organic medicines may be assessed from their distribution coefficients between octanol and water. This strategy has been used in order to define the species of manganese in a number of phytomedicines and to study the distribution of manganese in decoctions of phytomedicines in the stomach and the intestine. The concentrations of manganese in the original herbal materials and in octanol- and water-soluble fractions were determined by flame atomic absorption spectrometry following mixed acid digestion. The acidities of gastric and intestinal juices, the phytomedical composition and the compatibility of phytomedicines, i.e. the combination of single phytomedicines, greatly affected the manganese complexing ligands and determined the species and bioavailability of manganese. It is concluded that a knowledge of the level of octanol-soluble manganese in a phytomedicine could form the basis of dosage design in order to avoid manganese overload.

  16. Simultaneous and direct determination of iron and nickel in biological solid samples by high-resolution continuum source graphite furnace atomic absorption spectrometry.

    PubMed

    Gómez-Nieto, Beatriz; Gismera, Ma Jesús; Sevilla, Ma Teresa; Procopio, Jesús R

    2013-11-15

    The simultaneous and direct determination of nickel and iron in plants and lichens has been investigated using high-resolution continuum source graphite furnace atomic absorption spectrometry. The primary resonance line for nickel at 232.003 nm and the adjacent secondary line for iron at 232.036 nm have been used for this purpose. The optimization of the experimental conditions was performed using a pine needles certified reference material (SRM 1575a). The influence of pyrolysis and atomization temperatures, the amount of solid sample introduced into the graphite furnace and the use of aqueous or solid standard for calibration were studied. The spectral interferences caused by absorption of the concomitants of the solid sample were detected and corrected using a least square algorithm. Aliquots of 0.1-1mg of the solid samples were weighed onto the solid sampling platforms and analyzed directly, without addition of any reagents. The limits of detection were 25 µg kg(-1) for nickel and 0.40 mg kg(-1) for iron and the precision, expressed as the relative standard deviation, ranged from 7% to 12%. The proposed method was used to determine both metals in different bioindicator samples with successful results.

  17. Synthesis of a new molecularly imprinted polymer for sorption of the silver ions from geological and antiseptic samples for determination by flame atomic absorption spectrometry.

    PubMed

    Hashemi-Moghaddam, Hamid; Yahyazadeh, Faegheh; Vardini, Mohammad Taghi

    2014-01-01

    A new molecularly imprinted polymer (MIP) was synthesized using methacrylic acid (functional monomer), ethylene glycol dimethacrylate (crosslinker), 2,2'-azobisisobutironitril (initiator), silver (Ag) dithizone complex (template), and chloroform (porogenic solvent). This process was a noncovalent, bulk, thermal radical-polymerization. To compare the performance of this polymer, control polymer (nonimprinted polymer) was prepared under well-defined conditions without the use of a template. Extraction experiments were performed on the MIP and a nonimprinted polymer. Then, various parameters were optimized, such as pH, time, concentration of sample, and type of eluent for elution of Ag from polymer. In addition, interfering effects were investigated on the absorption of Ag by the MIP. This polymer was used for the rapid extraction and preconcentration of Ag from an antiseptic and geological sample. Finally, the amount of Ag was measured by flame atomic absorption spectrometry after preconcentration by the synthesized MIP, and results were compared with a direct inductively coupled plasma method. The results showed high performance of this method in preconcentration of Ag.

  18. Simultaneous determination of cobalt and nickel in vitamin B12 samples using high-resolution continuum source atomic absorption spectrometry.

    PubMed

    Adolfo, Franciele Rovasi; do Nascimento, Paulo Cícero; Bohrer, Denise; de Carvalho, Leandro Machado; Viana, Carine; Guarda, Ananda; Nunes Colim, Alexsandro; Mattiazzi, Patricia

    2016-01-15

    Nickel and cobalt were simultaneously assayed in vitamin B12 formulations by using atomic spectrometry. The proposed method is based on a compromise between the proximity of specific Ni and Co spectral lines and the relative abundances of the analytes in the samples. The analytes were found in concentrations ranging from 9.48 to 26.20µg L(-1) (Ni) and from 156.90 to 279.25mg L(-1) (Co) in the commercial samples of vitamin B12. The limits of detection and quantification were 1.21 and 3.64mg L(-1) for Co and 0.39 and 1.19µg L(-1) for Ni. Sample cleanup was not necessary for the determinations, and the interferences were discussed.

  19. Spectral aspects of the determination of Si in organic and aqueous solutions using high-resolution continuum source or line source flame atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Kowalewska, Zofia; Pilarczyk, Janusz; Gościniak, Łukasz

    2016-06-01

    High-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) was applied to reveal and investigate spectral interference in the determination of Si. An intensive structured background was observed in the analysis of both aqueous and xylene solutions containing S compounds. This background was attributed to absorption by the CS molecule formed in the N2O-C2H2 flame. The lines of the CS spectrum at least partially overlap all five of the most sensitive Si lines investigated. The 251.611 nm Si line was demonstrated to be the most advantageous. The intensity of the structured background caused by the CS molecule significantly depends on the chemical form of S in the solution and is the highest for the most-volatile CS2. The presence of O atoms in an initial S molecule can diminish the formation of CS. To overcome this S effect, various modes of baseline fitting and background correction were evaluated, including iterative background correction (IBC) and utilization of correction pixels (WRC). These modes were used either independently or in conjunction with least squares background correction (LSBC). The IBC + LSBC mode can correct the extremely strong interference caused by CS2 at an S concentration of 5% w:w in the investigated solution. However, the efficiency of this mode depends on the similarity of the processed spectra and the correction spectra in terms of intensity and in additional effects, such as a sloping baseline. In the vicinity of the Si line, three lines of V were recorded. These lines are well-separated in the HR-CS FAAS spectrum, but they could be a potential source of overcorrection when using line source flame atomic absorption spectrometry (LS FAAS). The expected signal for the 251.625 nm Fe line was not registered at 200 mg L- 1 Fe concentration in the solution, probably due to the diminished population of Fe atoms in the high-temperature flame used. The observations made using HR-CS FAAS helped to establish a "safe" level

  20. Speciation of methyl- and butyltin compounds and inorganic tin in oysters by hydride generation atomic absorption spectrometry

    SciTech Connect

    Han, J.S.; Weber, J.H.

    1988-02-15

    Because of the toxicity of tributyltin originating from many antifouling marine paints, there is much concern about its effect on aquatic life and, particularly, on shellfish. This paper describes speciation of inorganic tin, methyltin compounds, and butyltin compounds from oyster samples. The authors validated the hydride generation atomic absorption spectrophotometric technique by demonstrating ca. 100% recovery from spiked samples and by the absence of any organotin decomposition products. Absolute detection limits (3sigma) are 1.1-2.5 ng for 0.1-g oyster samples (wet weight). This method is superior to published techniques because of careful validation, low limits of detection, and minimal sample manipulation.

  1. Monitoring complex trace-gas mixtures by long-path laser absorption spectrometry. [in long duration manned mission closed environments

    NASA Technical Reports Server (NTRS)

    Green, B. D.; Steinfeld, J. I.

    1976-01-01

    Laser-based spectrophotometric methods, which have been proposed for the detection of trace concentrations of gaseous contaminants, include Raman and passive radiometry. The paper discusses a simple long-path laser absorption method which is capable of resolving complex mixtures of closely related trace contaminants at ppm levels. A number of species were selected which are most likely to accumulate in closed environments, such as submarines or long-duration manned space flights. Absorption coefficients at CO2 laser wavelengths were measured, accurate to + 3 per cent or better, for each of these species. This data base was then used to determine the presence and concentration of the contaminants in prepared mixtures of 12 to 15 gases. Computer programs have been developed which will permit a real-time analysis of the monitored atmosphere. Minimum detectable concentrations for individual species are generally in the ppm range, and are not seriously degraded by interferences even in complex mixtures. Estimates of the dynamic range of this monitoring technique for various system configurations and comparison with other methods of analysis are discussed

  2. Determination of yttrium and rare-earth elements in rocks by graphite-furnace atomic-absorption spectrometry.

    PubMed

    Gupta, J G

    1981-01-01

    With use of synthetic solutions and several international standard reference materials a method has been developed for determining traces of Y, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu in rocks by electrothermal atomization in a pyrolytically-coated graphite furnace. Depending on the element, the sensitivity is of the order of 10(-9)-10(-12) g at 2500 degrees . To avoid matrix interferences the lanthanides are separated from the common elements by co-precipitation with calcium and iron as carriers. The data for Canadian reference rock SY-2 (syenite), U.S.G.S. reference rocks W-2 (diabase), DNC-1 (diabase) and BIR-1 (basalt), and South African reference rock NIM-18/69 (carbonatite) obtained by graphite-furnace atomization are compared with the values obtained by flame atomic-absorption. The results are in good agreement with literature values.

  3. Determination of boron in blood, urine and bone by electrothermal atomic absorption spectrometry using zirconium and citric acid as modifiers

    NASA Astrophysics Data System (ADS)

    Burguera, Marcela; Burguera, José Luis; Rondón, Carlos; Carrero, Pablo

    2001-10-01

    A comparative study of various potential chemical modifiers (Au, Ba, Be, Ca, Cr, Ir, La, Lu, Mg, Ni, Pd, Pt, Rh, Ru, Sr, V, W, and Zr), and different 'coating' treatments (Zr, W, and W+Rh) of the pyrolytic graphite platform of a longitudinally heated graphite tube atomizer for thermal stabilization and determination of boron was undertaken. The use of Au, Ba, Be, Cr, Ir, Pt, Rh, Ru, Sr and V as modifiers, and of W+Rh coating produced erratic, and noisy signals, while the addition of La, Ni and Pd as modifiers, and the W coating had positive effects, but with too high background absorption signals, rendering their use unsuitable for boron determination even in aqueous solutions. The atomic absorption signal for boron was increased and stabilized when the platform was coated with Zr, and by the addition of Ca, Mg, Lu, W or Zr as modifiers. Only the addition of 10 μg of Zr as a modifier onto Zr-treated platforms allowed the use of a higher pyrolysis temperature without analyte losses. The memory effect was minimized by incorporating a cleaning step with 10 μl of 50 g l -1 NH 4F HF after every three boron measurements. The addition of 10 μl of 15 g l -1 citric acid together with Zr onto Zr-treated platforms significantly improved the characteristic mass to m0=282 pg, which is adequate for biological samples such as urine and bone, although the sensitivity was still inadequate for the determination of boron in blood of subjects without supplementary diet. Under optimized conditions, the detection limit (3σ) was 60 μg l -1. The amount of boron found in whole blood, urine and femur head samples from patients with osteoporosis was in agreement with values previously reported in the literature.

  4. Speciation of nickel in airborne particulate matter by means of sequential extraction in a micro flow system and determination by graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry.

    PubMed

    Fuichtjohann, L; Jakubowski, N; Gladtke, D; Klocko, D; Broekaert, J A

    2001-12-01

    A four-stage sequential extraction procedure for the speciation of nickel has been applied to ambient aerosol samples. The determination of the soluble, sulfidic, metallic and oxidic Ni fractions in particulate matter was carried out by graphite furnace (electrothermal) atomic absorption spectrometry (ETAAS) and inductively coupled plasma mass spectrometry (ICP-MS). An EDTA solution, a mixture of diammonium citrate and hydrogen peroxide, and a KCuCl3 solution were used as leaching agents for the determination of the soluble, sulfidic and metallic species, respectively, and nitric acid was used for the determination of oxidic compounds after microwave digestion of particulate matter sampled on filters. A new micro scale filter holder placed in a closed flow injection analysis (FIA) system for use in nickel speciation by means of sequential extraction, and the results of the optimisation of the extraction conditions are described. The temperature program for ETAAS was optimised for all extraction solutions with the aid of temperature curves. Pyrolysis temperatures of 900. 600 and 1,000 degrees C were found to be optimum for EDTA, hydrogen peroxide plus ammonium citrate and KCuCl3-containing solutions, respectively. Airborne dust was sampled on lilters at two locations near to a metallurgical plant in Dortmund, Germany. Concentrations in the low ng m(-3) range down to the detections limits (0.1-0.3 ng m(-3)) and various nickel species were found to be present in the collected dust. The mean fractions of total nickel (sampling period of one month) were found to contain 36+20% of soluble, 6 +/- 4% of sulfidic, 11 +/- 15% of metallic and 48 +/- 18% of oxidic nickel.

  5. Simultaneous determination of iron and nickel in fluoropolymers by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry.

    PubMed

    Soares, Bruno M; Santos, Rafael F; Bolzan, Rodrigo C; Muller, Edson I; Primel, Ednei G; Duarte, Fabio A

    2016-11-01

    This paper reports the development of a method of simultaneous determination of iron and nickel in fluoropolymers by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) with direct solid sampling. In order to carry out simultaneous measurements, both the main resonance line of nickel (232.003nm) and the adjacent secondary line of iron (232.036nm) were monitored in the same spectral window. The proposed method was optimized with a perfluoroalkoxy (PFA) sample and was applied to the determination of iron and nickel in fluorinated ethylene propylene (FEP) and modified polytetrafluoroethylene (PTFE-TFM) samples. Pyrolysis and atomization temperatures, as well as the use of Pd and H2 (during pyrolysis) as chemical modifiers, were carefully investigated. Compromise temperatures for pyrolysis and atomization of both analytes were achieved at 800 and 2300°C, respectively, using only 0.5Lmin(-1) H2 as chemical modifier during pyrolysis. Calibration curves were performed with aqueous standards by using a single solution which contained both analytes. Limits of detection were 221 and 9.6ngg(-1) for iron and nickel, respectively. Analyte concentrations in all samples ranged from 3.53 to 12.4µgg(-1) for iron and from 37 to 78ngg(-1) for nickel, with relative standard deviation less than 19%. Accuracy was evaluated by comparing these results with those obtained by inductively coupled plasma mass spectrometry after sample digestion by microwave-induced combustion and no significant statistical difference was observed.

  6. Feasibility of using solid sampling graphite furnace atomic absorption spectrometry for speciation analysis of volatile and non-volatile compounds of nickel and vanadium in crude oil.

    PubMed

    Silva, Márcia M; Damin, Isabel C F; Vale, Maria Goreti R; Welz, Bernhard

    2007-03-30

    A method for the direct determination of volatile and non-volatile nickel and vanadium compounds in crude oil without previous treatment using direct solid sampling graphite furnace atomic absorption spectrometry is proposed. The crude oil samples were weighed directly onto solid sampling platforms using a microbalance and introduced into a transversely heated solid sampling graphite tube. In previous work of our group losses of volatile nickel and vanadium compounds have been detected, whereas other nickel and vanadium compounds were thermally stable up to 1300 and 1600 degrees C, respectively. In order to avoid this problem different chemical modifiers (conventional and permanent) have been investigated. With 400microg of iridium as permanent modifier, the signal started to drop already after two atomization cycles, possibly because of an interaction of nickel (which is a catalyst poison) with iridium. Twenty micrograms of palladium applied in each determination was found to be optimum for both elements. The palladium was deposited on the platform and submitted to a drying step at 150 degrees C for 75s. After that the sample was added onto the platform and submitted to the furnace program. The influence of sample mass on the linearity of the response and on potential measurement errors was also investigated using four samples with different nickel content. For the sample with the lowest nickel concentration the relationship between mass and integrated absorbance was found to be non-linear when a high sample mass was introduced. It was suspected that the modifier had not covered the entire platform surface, which resulted in analyte losses. This problem could be avoided by using 40microL of 0.5g L(-1) Pd with 0.05% Triton X-100. Calibration curves were established with and without modifier, with aqueous standards, oil-in-water emulsions and the certified reference material NIST SRM 1634c (trace metals in residual fuel oil). The sensitivity for aqueous standards

  7. Radiocarbon dating of archaeological samples (sambaqui) using CO(2) absorption and liquid scintillation spectrometry of low background radiation.

    PubMed

    Mendonça, Maria Lúcia T G; Godoy, José M; da Cruz, Rosana P; Perez, Rhoneds A R

    2006-01-01

    Sambaqui means, in the Tupi language, a hill of shells. The sambaquis are archaeological sites with remains of pre-historical Brazilian occupation. Since the sambaqui sites in the Rio de Janeiro state region are older than 10,000 years, the applicability of CO(2) absorption on Carbo-sorb and (14)C determination by counting on a low background liquid scintillation counter was tested. In the present work, sambaqui shells were treated with H(3)PO(4) in a closed vessel in order to generate CO(2). The produced CO(2) was absorbed on Carbo-sorb. On saturation about 0.6g of carbon, as CO(2), was mixed with commercial liquid scintillation cocktail (Permafluor), and the (14)C activity determined by counting on a low background counter, Packard Tricarb 3170 TR/SL, for a period of 1000 mins to enable detection of a radiocarbon age of 22,400 BP. But only samples with ages up to 3500 BP were submitted to the method because the samples had been collected in the municipality of Guapimirim, in archaeological sambaqui-type sites belonging to this age range. The same samples were sent to the (14)C Laboratory of the Centro de Energia Nuclear na Agricultura (CENA/USP) where similar results were obtained.

  8. The application of atomic absorption spectrometry for the determination of residual active pharmaceutical ingredients in cleaning validation samples.

    PubMed

    Bubnič, Zoran; Urleb, Uroš; Kreft, Katjuša; Veber, Marjan

    2011-03-01

    The objective of this work was the development and validation of atomic absorption spectrometric (AAS) methods for the determination of residual active pharmaceutical ingredients (API) in rinse samples for cleaning validation. AAS as an indirect method for the determination of API in rinse samples can be applied when it is in the form of salt with metal ions or when the metal ion is a part of the API's structure. The electrothermal AAS methods (aqueous and ethanol medium) for the determination of magnesium in esomeprazole magnesium and the flame AAS method for the determination of lithium in lithium carbonate in rinse samples were developed. Various combinations of solvents were tested and a combination of 1% aqueous or ethanol solution of nitric acid for esomeprazole magnesium and 0.1% aqueous solution of nitric acid for lithium carbonate were found to be the most suitable. The atomization conditions in the graphite furnace and in the flame were carefully studied to avoid losses of analyte and to achieve suitable sensitivity. The cleaning verification methods were validated with respect to accuracy, precision, linearity, limit of detection, and quantification. In all the cases, the limits of detection were at the microgram level. The methods were successfully applied for the determination of esomeprazole magnesium and lithium carbonate in rinse samples from cleaning procedures.

  9. Fast determination of phosphorus in honey, milk and infant formulas by electrothermal atomic absorption spectrometry using a slurry sampling procedure

    NASA Astrophysics Data System (ADS)

    López-García, I.; Viñas, P.; Romero-Romero, R.; Hernández-Córdoba, M.

    2007-01-01

    A procedure for the electrothermal atomic absorption spectrometric determination of phosphorus in honey, milk and infant formulas using slurried samples is described. Suspensions prepared in a medium containing 50% v/v concentrated hydrogen peroxide, 1% v/v concentrated nitric acid, 10% m/v glucose, 5% m/v sucrose and 100 mg l - 1 of potassium were introduced directly into the furnace. For the honey samples, multiple injection of the sample was necessary. The modifier selected was a mixture of 20 μg palladium and 5 μg magnesium nitrate, which was injected after the sample and before proceeding with the drying and calcination steps. Calibration was performed using aqueous standards prepared in the same suspension medium and the graph was linear between 5 and 80 mg l - 1 of phosphorus. The reliability of the procedure was checked by comparing the results obtained by the new developed method with those found when using a reference spectrophotometric method after a mineralization step, and by analyzing several certified reference materials.

  10. Wavelength-modulated tunable diode-laser absorption spectrometry for real-time monitoring of microbial growth.

    PubMed

    Shao, Jie; Xiang, Jindong; Axner, Ove; Ying, Chaofu

    2016-03-20

    It is important to monitor and assess the growth of micro-organisms under various conditions. Yet, thus far there has been no technique to do this with the required speed and accuracy. This work demonstrates swift and accurate assessment of the concentration of carbon dioxide that is produced by use of a wavelength-modulated tunable diode-laser based absorption spectroscopy (WM-TDLAS). It is shown by experiments on two types of bacteria, Staphylococcus aureus and Candida albicans, that the technique can produce high signal-to-noise-ratio data from bacteria grown in confined spaces and exposed to limited amounts of nutrients that can be used for extraction of growth parameters by fitting of the Gompertz model. By applying the technique to S. aureus bacteria at various temperatures (in the 25°C to 42°C range), it is specifically shown that both the maximum growth rate and the so-called lag time have a strong temperature dependence (under the specific conditions with a maximum of the former at 37°C) that matches conventional models well for bacterial growth. Hence, it is demonstrated that WM-TDLAS monitoring CO2 is a user-friendly, non-intrusive, and label-free technique that swiftly, and with high signal-to-noise-ratio, can be used for rapid (on the Hz scale) and accurate assessment of bacterial growth.

  11. Back-extraction of trace elements from organometallic-halide extracts for determination by flameless atomic absorption spectrometry

    USGS Publications Warehouse

    Clark, J.R.; Viets, J.G.

    1981-01-01

    The Methyl isobutyl ketone-Amine synerGistic Iodkte Complex (MAGIC) extraction system offers the advantage that a large number of trace elements can be rapidly determined with a single sample preparation procedure. However, many of the elements extracted by the MAGIC system form volatile organometallic halide salts when the organic extract is heated in the graphite furnace. High concentrations of some elements such as Cu and Zn extracted by the system from anomalous geological samples produce serious interferences when certain other elements are determined by flameless atomic absorption. Stripping systems have been developed using solutions of HNO3, H2SO4, and CH3COOH individually or combined with H2O2 in order to circumvent these problems. With these systems most of the elements in the organic extract can be sequentially stripped into an aqueous phase. Organometallic volatilization and the most serious interelement interferences, therefore, can be eliminated by stripping with various combinations of reagents in a series of steps.

  12. Determination of indium in high purity antimony by electrothermal atomic absorption spectrometry (ETAAS) using boric acid as a modifier.

    PubMed

    Dash, K; Thangavel, S; Chaurasia, S C; Arunachalam, J

    2006-10-15

    The use of boric acid as a modifier for the determination of trace amount of indium in high purity antimony by electrothermal atomic absorption is described. It was found that the negative influence of the hydrofluoric acid, used for the digestion could not be eliminated by using stabilized temperature platform furnace (STPF) alone. Due to the high dissociation energy (D(0)=506kJmol(-1)) of indium fluoride, it is difficult to dissociate in the gas phase and hence is lost. In presence of HF (used for the dissolution of antimony), the universal Pd-Mg modifier does not work satisfactorily. Additionally, rising corrosion and reduced tube lifetime were observed when the acid digested (HF-HNO(3)) antimony solution was injected in to the platform. Improvement in platform life and elimination of interferences were achieved by the addition of boric acid as a chemical modifier together with ruthenium coating of the platform. Corrosive changes of the transversely heated graphite atomizer (THGA) platform surface were examined by scanning electron microscopy. The standard addition method was applied. A characteristic mass of 36pg was obtained. The detection limit of the proposed method is around 0.04mugg(-1). The developed method was applied to the determination of indium in real samples. The data obtained by this method were in good agreement with those obtained by ICP-MS.

  13. Molecule formation mechanisms of strontium mono fluoride in high-resolution continuum source electrothermal atomic absorption spectrometry.

    PubMed

    Ozbek, Nil; Akman, Suleyman

    2013-01-01

    In this study, the molecule formation mechanisms of strontium mono fluoride used for the determination of fluorine in a high-resolution continuum source atomic absorption spectrophotometer was investigated. To distinguish between the gas-phase and the condensed-phase mechanisms, the analyte (F) and the molecule forming element (Sr) were injected on the solid sampling platform manually, as mixed or separately, and the absorbances/peak shapes were compared. There was no significant difference between the absorbances. In addition, the peak shapes and the appearance times were almost the same for the two cases. It was proposed that the main pathway for SrF formation is a gas-phase combination reaction between Sr and F. When Sr and F were mixed on the platform, it was expected that at first SrF2 would be formed in the condensed phase, and then at elevated temperatures it was partly decomposed while either losing one F atom to form SrF, or completely decomposed to its atoms in the gas phase.

  14. A technique coupling the analyte electrodeposition followed by in-situ stripping with electrothermal atomic absorption spectrometry for analysis of samples with high NaCl contents

    NASA Astrophysics Data System (ADS)

    Čánský, Zdeněk; Rychlovský, Petr; Petrová, Zuzana; Matousek, J. P.

    2007-03-01

    A technique coupling the analyte electrodeposition followed by in-situ stripping with electrothermal atomic absorption spectrometry has been developed for determination of lead and cadmium in samples with high salt contents. To separate the analyte from the sample matrix, the analyte was in-situ quantitatively electrodeposited on a platinum sampling capillary serving as the cathode (sample volume, 20 μL). The spent electrolyte containing the sample matrix was then withdrawn, the capillary with the analyte deposited was washed with deionized water and the analyte was stripped into a chemically simple electrolyte (5 g/L NH 4H 2PO 4) by reversing the polarity of the electrodeposition circuit. Electrothermal atomization using a suitable optimized temperature program followed. A fully automated manifold was designed for this coupled technique and the appropriate control software was developed. The operating conditions for determination of Pb and Cd in samples with high contents of inorganic salts were optimized, the determination was characterized by principal analytical parameters and its applicability was verified on analyses of urine reference samples. The absolute limits of detection for lead and cadmium (3 σ criterion) in a sample containing 30 g/L NaCl were 8.5 pg and 2.3 pg, respectively (peak absorbance) and the RSD values amounted to 1.6% and 1.9% for lead (at the 40 ng mL - 1 level) and cadmium (at the 4.0 ng mL - 1 level), respectively. These values (and also the measuring sensitivity) are superior to the results attained in conventional electrothermal atomic absorption spectrometric determination of Pb and Cd in pure solutions (5 g/L NH 4H 2PO 4). The sensitivity of the Pb and Cd determination is not affected by the NaCl concentration up to a value of 100 g/L, demonstrating an efficient matrix removal during the electrodeposition step.

  15. Fast sequential multi-element determination of major and minor elements in environmental samples and drinking waters by high-resolution continuum source flame atomic absorption spectrometry.

    PubMed

    Gómez-Nieto, Beatriz; Gismera, Ma Jesús; Sevilla, Ma Teresa; Procopio, Jesús R

    2015-01-07

    The fast sequential multi-element determination of 11 elements present at different concentration levels in environmental samples and drinking waters has been investigated using high-resolution continuum source flame atomic absorption spectrometry. The main lines for Cu (324.754 nm), Zn (213.857 nm), Cd (228.802 nm), Ni (232.003 nm) and Pb (217.001 nm), main and secondary absorption lines for Mn (279.482 and 279.827 nm), Fe (248.327, 248.514 and 302.064 nm) and Ca (422.673 and 239.856 nm), secondary lines with different sensitivities for Na (589.592 and 330.237 nm) and K (769.897 and 404.414 nm) and a secondary line for Mg (202.582 nm) have been chosen to perform the analysis. A flow injection system has been used for sample introduction so sample consumption has been reduced up to less than 1 mL per element, measured in triplicate. Furthermore, the use of multiplets for Fe and the side pixel registration approach for Mg have been studied in order to reduce sensitivity and extend the linear working range. The figures of merit have been calculated and the proposed method was applied to determine these elements in a pine needles reference material (SRM 1575a), drinking and natural waters and soil extracts. Recoveries of analytes added at different concentration levels to water samples and extracts of soils were within 88-115% interval. In this way, the fast sequential multi-element determination of major and minor elements can be carried out, in triplicate, with successful results without requiring additional dilutions of samples or several different strategies for sample preparation using about 8-9 mL of sample.

  16. Determination of chlorine via the CaCl molecule by high-resolution continuum source graphite furnace molecular absorption spectrometry and direct solid sample analysis.

    PubMed

    Guarda, Ananda; Aramendía, Maite; Andrés, Irene; García-Ruiz, Esperanza; do Nascimento, Paulo Cícero; Resano, Martín

    2017-01-01

    This work investigates the possibilities of high-resolution continuum source graphite furnace molecular absorption spectrometry for the direct determination of Cl in solid samples via the CaCl molecule and measurement of its molecular absorption. The method proposed is based on addition of 400µg Ca as molecule-forming reagent and of 20µgPd as chemical modifier, which helps to stabilize the analyte and enhances sensitivity. The molecular spectrum for CaCl offers different lines with different limits of detection and linear ranges, which permitted to analyze solid samples with different Cl contents. The lowest limit of detection (0.75ng Cl, corresponding to 0.75µgg(-1) for a typical sample mass of 1mg) could be achieved by combination of three of the most sensitive lines in the vicinity of 620.862nm, while the amplest linear range (up to 860ng Cl) was achieved by selection of the less sensitive line at 377.501nm. The method developed enabled the direct determination of Cl in solid samples using simple external calibration with aqueous standards. Good precision (5-9% RSD) and accuracy was attained in a series of certified samples of very different nature (i.e. coal, iron oxide, polyethylene, human hair, pine needles, rice flour and milk) and with very different Cl contents, ranging from about 50µgg(-1) to 1% (w/w) Cl. The method appears as particularly useful for Cl determination in samples with elevated Ca contents, for which biased results with other diatomic molecules, such as AlCl or SrCl, may be obtained.

  17. Direct and simultaneous determination of Cr and Fe in crude oil using high-resolution continuum source graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Dittert, Ingrid M.; Silva, Jessee S. A.; Araujo, Rennan G. O.; Curtius, Adilson J.; Welz, Bernhard; Becker-Ross, Helmut

    2009-06-01

    A simple, fast and sensitive direct method for the simultaneous determination of Cr and Fe in crude oil samples is proposed using high-resolution continuum source graphite furnace atomic absorption spectrometry. No sample preparation is used except for a 10-minute homogenization in an ultrasonic bath. Aliquots of 0.1-4 mg of the samples are weighed onto solid sampling platforms and analyzed directly using aqueous standards for calibration. The simultaneous determination was possible because there is a secondary Fe line at 358.120 nm in the vicinity of the most sensitive Cr line at 357.868 nm, and both absorption lines were within the wavelength interval covered by the linear charge-coupled device array detector. It has also been of advantage that the sensitivity ratio between the two analytical lines corresponded roughly to the concentration ratio of the two elements found in crude oil, and that both analytes have very similar volatility, so that no compromises had to be made regarding pyrolysis and atomization temperatures. Two oil reference materials have been analyzed and the results were in agreement with the certified or reported values. Characteristic masses of 3.6 pg and 0.5 ng were obtained for Cr and Fe, respectively. The limits of detection (3 σ, n = 10) were 1 µg kg - 1 for Cr and 0.6 mg kg - 1 for Fe, and the precision, expressed as the relative standard deviation, ranged from 4 to 20%, which is often acceptable for a rapid direct analytical procedure. Five crude oils samples were analyzed.

  18. Liquid chromatography-electrothermal atomic absorption spectrometry for the separation and preconcentration of molybdenum in milk and infant formulas.

    PubMed

    López-García, I; Viñas, P; Romero-Romero, R; Hernández-Córdoba, M

    2007-08-06

    Two procedures for the electrothermal atomic absorption spectrometric determination of molybdenum in milk and infant formulas using slurried samples are described. For powdered milk samples, 10% (m/v) slurries were prepared in a medium containing 25 and 75% (v/v) concentrated hydrogen peroxide and hydrofluoric acid, respectively, and introduced directly into the furnace. Palladium (200 microg mL(-1)) was used as the modifier and calibration was carried out using aqueous standards prepared in the same medium. The detection limit was 0.02 microg g(-1) for powdered milk samples suspended at 10% (m/v) (equivalent to 2 microg L(-1)). The relative standard deviation (R.S.D.) for five measurements was 1.9%, the characteristic mass being 25 pg. For liquid milk samples, a procedure was proposed based on preconcentration and removal of the matrix, using ionic exchange (Amberlite IRA 743) and elution of molybdenum with 5% (m/v) NaOH. In this case, a 30-fold improvement in the calibration slope was achieved, leading to a detection limit of 0.04 microg L(-1) for liquid samples diluted to 10%. The R.S.D. was 3.5%. Using a size-based separation procedure, it was found that molybdenum is present in its inorganic form or associated to low molecular weight substances in cow milk, while in breast milk it is associated to proteins. The reliability of the procedure was checked by comparing the results obtained with those found using a previous mineralization stage and by analyzing three certified reference materials, namely, BCR 063R (skim milk powder), NBS 1549 (non-fat milk powder) and NBS 8435 (whole milk powder).

  19. A medium-throughput functional assay of KCNQ2 potassium channels using rubidium efflux and atomic absorption spectrometry.

    PubMed

    Scott, Clay W; Wilkins, Deidre E; Trivedi, Shephali; Crankshaw, Denis J

    2003-08-15

    Heterologous expression of KCNQ2 (Kv7.2) results in the formation of a slowly activating, noninactivating, voltage-gated potassium channel. Using a cell line that stably expresses KCNQ2, we developed a rubidium flux assay to measure the functional activity and pharmacological modulation of this ion channel. Rubidium flux was performed in a 96-well microtiter plate format; rubidium was quantified using an automated atomic absorption spectrometer to enable screening of 1000 data points/day. Cells accumulated rubidium at 37 degrees C in a monoexponential manner with t(1/2)=40min. Treating cells with elevated extracellular potassium caused membrane depolarization and stimulation of rubidium efflux through KCNQ2. The rate of rubidium efflux increased with increasing extracellular potassium: the t(1/2) at 50mM potassium was 5.1 min. Potassium-stimulated efflux was potentiated by the anticonvulsant drug retigabine (EC(50)=0.5 microM). Both potassium-induced and retigabine-facilitated efflux were blocked by TEA (IC(50)s=0.4 and 0.3mM, respectively) and the neurotransmitter release enhancers and putative cognition enhancers linopirdine (IC(50)s=2.3 and 7.1 microM, respectively) and XE991 (IC(50)s=0.3 and 0.9 microM, respectively). Screening a collection of ion channel modulators revealed additional inhibitors including clofilium (IC(50) = 27 microM). These studies extend the pharmacological profile of KCNQ2 and demonstrate the feasibility of using this assay system to rapidly screen for compounds that modulate the function of KCNQ2.

  20. A flow-batch internal standard procedure for iron determination in hydrated ethanol fuel by flame atomic absorption spectrometry.

    PubMed

    da Silva, José Edson; da Silva, Fábio André; Pimentel, M Fernanda; Honorato, Ricardo Saldanha; da Silva, Valdinete Lins; Montenegro, Maria da Conceição B S M; Araújo, Alberto N

    2006-10-15

    A flow-batch manifold coupled to a flame atomic absorption spectrometer was evaluated to assess the iron content by the internal standard method in hydrated ethanol used as fuel in automotive industry. For this assessment official methods require calibration procedures with matrix matching, making it difficult to obtain accurate results for samples adulterated by the addition of water. Nickel was selected as the internal standard since it is usually absent in samples and because it requires similar conditions of atomization. After procedure optimization, which requires about 4.25mL of sample and standard per measurement, it was possible to get linear analytical response for iron concentrations between 0.12 and 1.40mgL(-1) and a detection limit of 0.04mgL(-1). Eighteen samples were collected randomly from fuel stations in Pernambuco (Brazil) and iron concentration was determined using the proposed procedure. Comparison of results obtained (0.20-1.50mgL(-1)) showed a mean standard error of 3.9%, with 3.8% and 2.3% calculated for the mean variation coefficients of the proposed method and the reference procedure, respectively. For adulterated samples (0.12-0.64mgL(-1)), the mean standard error was 4.8% when compared with the standard addition method. These results allowed concluding that the proposed procedure is adequate to accomplish the determination of iron in ethanol fuel in a large scale basis with a sampling rate of about 10h(-1).

  1. Determination of trace elements in dolomite and gypsum by atomic absorption spectrometry: overcoming the matrix interference by flotation separation

    NASA Astrophysics Data System (ADS)

    Stafilov, Trajče; Zendelovska, Dragica; Pavlovska, Gorica; Čundeva, Katarina

    2002-05-01

    The interferences of Ca and Mg as matrix elements in dolomite and gypsum on Ag, Cd, Cr, Mn, Tl and Zn absorbances during their electrothermal atomic absorption spectrometric (ETAAS) determination are investigated. The results reveal that Ca and Mg do not interfere on Zn and Mn, tend to decrease absorbances of Ag, Cd and Cr, while Tl suffers the most significant influence. A flotation separation method is proposed to eliminate matrix interferences. Hydrated iron(III) oxide, Fe 2O 3· xH 2O, and iron(III) hexamethylenedithiocarbamate, Fe(HMDTC) 3, are applied as flotation collectors. The influence of hydrophobic dithiocarbamate anion, HMDTC, on flotation recoveries of each analyte is studied. The most suitable concentrations of dolomite and gypsum solutions for flotation are determined. To avoid flotation suppression due to the reaction of Ca 2+ and Mg 2+ with surfactant ions, a fit foaming agent was selected. The elements present in dolomite and gypsum as traces have been analyzed by ETAAS. Their ETAAS limits of detection following flotation are found to be 0.021 μg·g -1 for Ag, 0.019 μg·g -1 for Cd, 0.014 μg·g -1 for Cr and 0.11 μg·g -1 for Tl. The determination of Mn and Zn can be performed by flame AAS (FAAS). The limit of detection for Mn is 1.5 μg·g -1, while for Zn 0.8 μg·g -1.

  2. Validation of an analytical method for the determination of cadmium (Cd) in fish by atomic absorption spectrometry with electrothermal atomisation.

    PubMed

    Costa, L C S M; Neto, A P N; Araújo, M Q; Melo, M C C; Furtado, D M S; Kikuchi, A N S

    2012-01-01

    The validation of an analytical method was carried out for the determination of cadmium (Cd) in fish. The method was based on sample digestion in a microwave oven and subsequent reading using an atomic absorption spectrometer with a graphite furnace. The factorial design of experiments was applied to assess method ruggedness using the methodology of Box et al. [Box GEP, Hunter WG, Hunter JS. 1978. Statistics for experiments: an introduction to design, data analysis and model building. New York (NY): Wiley], studying the influence of sample mass, volume and concentration of acid used for sample digestion and the volume of modifier used. To study the possible matrix effect in the determination of Cd, the standard addition method was also performed. The results were treated using the OLS method. For the normality test a homoskedastic distribution was observed for the developed method and the results were adjusted to the statistical model proposed. F-tests and Student's t-tests indicated that there was no matrix effect on the calibration curve between the concentration range 1.0-10.0 µg Cd l(-1). Parameters such as selectivity, precision, decision limit, detection capability and limit of quantification were established by the method of standard addition to blank samples. The limit of quantification was 6.8 µg kg(-1). Accuracy, which was evaluated by using a certified reference material, was 107.0%. The recovery of the spiked analyte was 93.69% for the concentration of 50 µg kg(-1). Precision was defined by the coefficient of variation observed (Horrat value), estimated in terms of repeatability and reproducibility, and the values were below the limit, which is 2.0. The validation procedure confirmed the suitability of the method.

  3. Validation of an analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals in soil

    PubMed Central

    2013-01-01

    Background The aim of this paper was the validation of a new analytical method based on the high-resolution continuum source flame atomic absorption spectrometry for the fast-sequential determination of several hazardous/priority hazardous metals (Ag, Cd, Co, Cr, Cu, Ni, Pb and Zn) in soil after microwave assisted digestion in aqua regia. Determinations were performed on the ContrAA 300 (Analytik Jena) air-acetylene flame spectrometer equipped with xenon short-arc lamp as a continuum radiation source for all elements, double monochromator consisting of a prism pre-monocromator and an echelle grating monochromator, and charge coupled device as detector. For validation a method-performance study was conducted involving the establishment of the analytical performance of the new method (limits of detection and quantification, precision and accuracy). Moreover, the Bland and Altman statistical method was used in analyzing the agreement between the proposed assay and inductively coupled plasma optical emission spectrometry as standardized method for the multielemental determination in soil. Results The limits of detection in soil sample (3σ criterion) in the high-resolution continuum source flame atomic absorption spectrometry method were (mg/kg): 0.18 (Ag), 0.14 (Cd), 0.36 (Co), 0.25 (Cr), 0.09 (Cu), 1.0 (Ni), 1.4 (Pb) and 0.18 (Zn), close to those in inductively coupled plasma optical emission spectrometry: 0.12 (Ag), 0.05 (Cd), 0.15 (Co), 1.4 (Cr), 0.15 (Cu), 2.5 (Ni), 2.5 (Pb) and 0.04 (Zn). Accuracy was checked by analyzing 4 certified reference materials and a good agreement for 95% confidence interval was found in both methods, with recoveries in the range of 94–106% in atomic absorption and 97–103% in optical emission. Repeatability found by analyzing real soil samples was in the range 1.6–5.2% in atomic absorption, similar with that of 1.9–6.1% in optical emission spectrometry. The Bland and Altman method showed no statistical significant difference

  4. A Green Preconcentration Method for Determination of Cobalt and Lead in Fresh Surface and Waste Water Samples Prior to Flame Atomic Absorption Spectrometry

    PubMed Central

    Naeemullah; Kazi, Tasneem Gul; Shah, Faheem; Afridi, Hassan Imran; Khan, Sumaira; Arian, Sadaf Sadia; Brahman, Kapil Dev

    2012-01-01

    Cloud point extraction (CPE) has been used for the preconcentration and simultaneous determination of cobalt (Co) and lead (Pb) in fresh and wastewater samples. The extraction of analytes from aqueous samples was performed in the presence of 8-hydroxyquinoline (oxine) as a chelating agent and Triton X-114 as a nonionic surfactant. Experiments were conducted to assess the effect of different chemical variables such as pH, amounts of reagents (oxine and Triton X-114), temperature, incubation time, and sample volume. After phase separation, based on the cloud point, the surfactant-rich phase was diluted with acidic ethanol prior to its analysis by the flame atomic absorption spectrometry (FAAS). The enhancement factors 70 and 50 with detection limits of 0.26 μg L−1 and 0.44 μg L−1 were obtained for Co and Pb, respectively. In order to validate the developed method, a certified reference material (SRM 1643e) was analyzed and the determined values obtained were in a good agreement with the certified values. The proposed method was applied successfully to the determination of Co and Pb in a fresh surface and waste water sample. PMID:23227429

  5. Determination of chromium(VI) and lead(II) in drinking water by electrokinetic flow analysis system and graphite furnace atomic absorption spectrometry.

    PubMed

    Yang, L; He, Y Z; Gan, W E; Li, M; Qu, Q S; Lin, X Q

    2001-08-30

    An electrokinetic flow analysis system (EKFA) using an electroosmotic pump (Peo) and a bi-directional electrostacking (BDES) unit is introduced in this paper. Large flow range, moderate carrier pressure, low performance voltage and stable flow rate, especially in mulmin(-1) level, are the main specialties of the Peo. Diethanolamine, 0.5 mM, is selected as its carrier to improve the pump efficiency and stability further. Moreover, BDES, a feasibility investigation for the simultaneous separation and pre-concentration of cations and anions, and graphite furnace atomic absorption spectrometry (GFAAS) determination are presented. The calibration series for both of Cr(VI) and Pb(II) are from 0.2 to 40 mugl(-1) with 10 mul pipette volume and GFAAS determination directly. The detection limit of Cr(VI) and Pb(II) with 10 min BDES is 10 and 13 ngl(-1)(3sigma of blank, n=11), respectively. The recovery of Cr(VI) and Pb(II) is (103-105)+/-1% and (95.9-96.9)+/-1.0% with three independent determinations, respectively. The investigated method is also suitable for the simultaneous separation and pre-concentration of trace cations and anions in low conductivity sample solutions with different detection instruments.

  6. Exploring in vivo violacein biosynthesis by application of multivariate curve resolution on fused UV-VIS absorption, fluorescence, and liquid chromatography-mass spectrometry data.

    PubMed

    Dantas, Clecio; Tauler, Romà; Ferreira, Márcia Miguel Castro

    2013-02-01

    In this work, the application of multivariate curve resolution-alternating least squares (MCR-ALS) is proposed for extracting information from multitechnique fused multivariate data (UV-VIS absorption, fluorescence, and liquid chromatography-mass spectrometry) gathered during the biosynthesis of violacein pigment. Experimental data sets were pretreated and arranged in a row-wise augmented data matrix before their chemometric investigation. Five different chemical components were resolved. Kinetic and spectral information about these components were obtained and their relationship with violacein biosynthesis was established. Three new chemical compounds with molar masses of 453, 465, and 479 u, until now not reported in the literature, were identified and proposed as intermediates in the biosynthesis of other indolocarbazoles. The precursor (tryptophan), one intermediate (deoxyviolacein), and the final product (violacein) of violacein biosynthesis were identified and characterized using the proposed approach. The chemometric procedure based on the MCR-ALS method has proved to be a powerful tool to investigate violacein biosynthesis and its application can be easily extended to the study of other bioprocesses.

  7. Lead and cadmium in human placentas and maternal and neonatal blood (in a heavily polluted area) measured by graphite furnace atomic absorption spectrometry.

    PubMed Central

    Baranowska, I

    1995-01-01

    OBJECTIVE--To measure the concentrations of the trace elements lead and cadmium in human placenta and in maternal and neonatal (cord) blood. To assess the influence of the strongly polluted environment on the content of metals in tissues and on the permeability of placenta to cadmium and lead. Various methods of mineralisation were tested before analysis. METHODS--Graphite furnace atomic absorption spectrometry was used for the determination of lead and cadmium. The samples for analysis were prepared by mineralisation under pressure in a Teflon bomb (HNO3, 110 degrees C), by wet ashing under normal pressure (HNO3 + H2O2 for 12 hours), and by microwave digestion in concentrated nitric acid. RESULTS--In analysed samples the following mean concentrations of cadmium and lead were found: in venous blood Pb = 72.50 ng/ml, Cd = 4.90 ng/ml; in placenta Pb = 0.50 microgram/g, Cd = 0.11 microgram/g; in cord blood Pb = 38.31 ng/ml, Cd = 1.13 ng/ml. CONCLUSION--High concentrations of lead and cadmium were found in placentas and in maternal blood whereas in neonatal blood there was an increased concentration of lead and only traces of cadmium. It is concluded that the placenta is a better barrier for cadmium than for lead. Among the examined methods of mineralisation, microwave digestion was the best. PMID:7795737

  8. Determination of trace lead in water samples by graphite furnace atomic absorption spectrometry after preconcentration with nanometer titanium dioxide immobilized on silica gel.

    PubMed

    Liu, Rui; Liang, Pei

    2008-03-21

    Nanometer titanium dioxide immobilized on silica gel (immobilized nanometer TiO2) was prepared by sol-gel method and characterized using X-ray diffraction (XRD) and scanning electron microscope (SEM). The adsorptive capability of immobilized nanometer TiO2 for lead was assessed in this work using column method. It was found that lead can be quantitatively retained by immobilized nanometer TiO2 in the pH range 4-7, then eluted completely with 1.0molL(-1) HCl. The adsorption capacity of immobilized nanometer TiO2 for Pb was found to be 3.16mgg(-1). A new method has been developed for the determination of trace lead based on preconcentration with a microcolumn packed with immobilized nanometer TiO2 prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS). The detection limit of this method for Pb was 9.5ngL(-1) with an enrichment factor of 50, and the relative standard deviations (R.S.D.s) was 3.2% at the 10ngmL(-1) Pb level. The method was validated using a certified reference material, and was applied for the determination of trace lead in water samples.

  9. Determination of total arsenic and arsenic(III) in phosphate fertilizers by hydride generation atomic absorption spectrometry after ultrasound-assisted extraction based on a control acid media.

    PubMed

    Rezende, Helen Cristine; Coelho, Nivia Maria Melo

    2014-01-01

    An ultrasound-assisted extraction procedure was developed for determination of inorganic arsenic (As) in phosphate fertilizer by hydride generation atomic absorption spectrometry. The variables that affect the hydride generation step were optimized, including the reducer, acid, sample flow rate, and concentrations of the acid and reducer. The determination of As(lll) was performed through the simple control of solution pH with a 0.5 M citric acid-sodium citrate buffer solution at pH 4.5, and total As was determined after a pre-reduction reaction with 1.0% (w/v) thiourea. Ultrasound-assisted acid extraction was performed, and the parameters sonication time and acid and Triton X-114 concentrations were optimized using a 23 factorial design and central composite design. LODs for As(lll) and total As were 0.029 and 0.022 microg/L, respectively. The accuracy of the method was confirmed with certified reference materials. The method was successfully applied in the determination of inorganic As in phosphate fertilizer samples.

  10. Separation and determination of copper in bottled water samples by combination of dispersive liquid--liquid microextraction and microsample introduction flame atomic absorption spectrometry.

    PubMed

    Citak, Demirhan; Tuzen, Mustafa

    2013-01-01

    A new and simple method for the determination of trace amounts of Cu(II) was developed by combination of dispersive liquid-liquid microextraction (DLLME) preconcentration and microsample introduction flame atomic absorption spectrometry. In this method, ethanol and chloroform were chosen as disperser and extraction solvents, respectively, and 1-nitroso-2-naphthol was used as the complexing agent. The factors affecting the extraction efficiency and determination of Cu(II), including extraction and disperser solvent nature and volume, concentration of the complexing agent, pH of the solution, extraction time, and matrix ions, were investigated. Under optimal conditions, the LOD for Cu(II) was 0.95 microg/L with a preconcentration factor of 70. The RSD was 1.9%. The accuracy of the developed DLLME method was verified by determination of Cu(II) in a certified reference material (NRCC-SLRS-4 river water). The relative error was -3.31%. The developed preconcentration procedure was successfully applied to the analysis of bottled drinking water samples.

  11. Determination of selenium in marine biological tissues by transverse heated electrothermal atomic absorption spectrometry with longitudinal Zeeman background correction and automated ultrasonic slurry sampling.

    PubMed

    Méndez, H; Alava, F; Lavilla, I; Bendicho, C

    2001-01-01

    A fast, sensitive, and reliable method for determination of selenium in marine biological tissues by electrothermal atomic absorption spectrometry with slurry sampling was developed. Slurries were prepared from fresh and frozen seafood samples that were previously homogenized, dried, and ground; particle sizes <100 microm were taken for analysis. A 3% (v/v) HNO3 solution containing 0.01% (v/v) Triton X-100 was used as slurry diluent. Slurries were mixed on an automated ultrasonic slurry sampler at 20% amplitude for 30 s just before an aliquot was injected into the furnace. The method was successfully validated against the following certified reference materials: NRCC CRM DORM-2 (Dogfish muscle); NRCC CRM TORT-2 (Lobster hepatopancreas); NRCC CRM DOLT-2 (Dogfish liver); and BCR CRM 278 (Mussel tissue), and was subsequently applied to determination of Se in 10 marine biological samples. The influences of the drying procedure (oven-, microwave-, and freeze-drying), matrix modifier amount, mass of solid material in cup, and pipetting sequence are discussed. The limit of determination of Se was 0.16 microg/g and the repeatability, estimated as between-batch precision, was in the range of 4-8%. Se contents in the samples ranged from 0.6 to 2.8 microg/g. The proposed method should be useful for fast assessment of the daily dietary intake of Se.

  12. Investigation of the transported heavy metal ions in xylem sap of cucumber plants by size exclusion chromatography and atomic absorption spectrometry.

    PubMed

    Mihucz, V G; Tatár, E; Kmethy, B; Záray, G; Cseh, E

    2000-07-15

    An 'off-line' high performance liquid chromatography-graphite furnace atomic absorption spectrometry (HPLC-GF-AAS) method using a size exclusion chromatography (SEC) column was developed to investigate heavy metal ions in xylem sap samples of cucumber plants grown in hydroponics containing iron as Fe(III)-ethylenediaminetetraacetate (Fe(III) EDTA), Fe(III) citrate or FeCl3 and exposed to lead, nickel or vanadium contamination. The SEC chromatogram of the samples contained the peak of nitrate ions (in significant concentration approximately 1400 microg/ml) and some small, unidentified compounds with molecular weight lower than 700 Da. The results indicate that Cu and Mn--which were added to the hydroponics as nutrient elements--determined in the collected fractions during the chromatographic runs are transported in the xylem vessels together with small inorganic ions like nitrate ions. In case of nickel other low-molecular weight compounds eluting earlier than the nitrate ions may take part in its transport toward the shoots. Lead could not be detected in the above mentioned fractions. Determination of vanadium in the fractions was not expected since it could not be detected in the sap samples.

  13. Speciation of inorganic arsenic species and total inorganic arsenic in rice using microwave-assisted dispersive liquid-liquid micro-extraction and electrothermal atomic absorption spectrometry.

    PubMed

    Ahmadi-Jouibari, Toraj; Fattahi, Nazir

    2015-01-01

    Human exposure to inorganic arsenic (iAs) via rice consumption is of increasing concern. In the present study, microwave-assisted dispersive liquid-liquid micro-extraction (MADLLME) and electrothermal atomic absorption spectrometry (ETAAS) were developed for the speciation of iAs in rice samples. After microwave-assisted digestion, the As(III) ion reacted with diethyldithiophosphoric acid (DDTP) to form an As-DDTP complex and was extracted at the same time. Some parameters affecting digestion, complex formation, and extraction were studied and optimised. Under the optimised conditions, a detection limit of 0.2 µg kg(-1) with a correlation coefficient of 0.9901 were obtained with a calibration curve in the range of 0.5-200 µg kg(-1). Total iAs was determined after reduction of As(V) to As(III) with sodium thiosulfate and potassium iodide, and As(V) was calculated by difference. The proposed extraction procedure was successfully applied for the determination of iAs ions in certified reference materials (NIST CRM 1568a and NMIJ CRM 7503a) and 10 rice samples produced in Iran and other Asian countries.

  14. Automatic On-line Solid-phase Extraction-Electrothermal Atomic Absorption Spectrometry Exploiting Sequential Injection Analysis for Trace Vanadium, Cadmium and Lead Determination in Human Urine Samples.

    PubMed

    Giakisikli, Georgia; Ayala Quezada, Alejandro; Tanaka, Junpei; Anthemidis, Aristidis N; Murakami, Hiroya; Teshima, Norio; Sakai, Tadao

    2015-01-01

    A fully automated sequential injection column preconcentration method for the on-line determination of trace vanadium, cadmium and lead in urine samples was successfully developed, utilizing electrothermal atomic absorption spectrometry (ETAAS). Polyamino-polycarboxylic acid chelating resin (Nobias chelate PA-1) packed into a handmade minicolumn was used as a sorbent material. Effective on-line retention of chelate complexes of analytes was achieved at pH 6.0, while the highest elution effectiveness was observed with 1.0 mol L(-1) HNO3 in the reverse phase. Several analytical parameters, like the sample acidity, concentration and volume of the eluent as well as the loading/elution flow rates, have been studied, regarding the efficiency of the method, providing appropriate conditions for the analysis of real samples. For a 4.5 mL sample volume, the sampling frequency was 27 h(-1). The detection limits were found to be 3.0, 0.06 and 2.0 ng L(-1) for V(V), Cd(II) and Pb(II), respectively, with the relative standard deviations ranging between 1.9 - 3.7%. The accuracy of the proposed method was evaluated by analyzing a certified reference material (Seronorm(TM) trace elements urine) and spiked urine samples.

  15. Multielement determination of cadmium and lead in urine by simultaneous electrothermal atomic absorption spectrometry with an end-capped graphite tube.

    PubMed

    Correia, Paulo R M; Nomura, Cassiana S; Oliveira, Pedro V

    2003-11-01

    A method for the multielement determination of cadmium and lead in urine is proposed by simultaneous electrothermal atomic absorption spectrometry (SIMAAS) with an end-capped transversely heated graphite atomizer (EC-THGA). The best conditions for cadmium and lead determination were obtained in the presence of NH4H2PO4 as a chemical modifier, using 500 degrees C and 1800 degrees C as the pyrolysis and atomization temperatures, respectively. Urine samples were diluted 1 + 4 directly in autosampler cups with a mixture of 0.125% (w/v) Triton X-100 + 2.5% (v/v) HNO3 + 0.31% (w/v) NH4H2PO4. The optimized heating program was carried out in 57 s, and the instrument calibration was done with aqueous reference solutions. The use of EC-THGA increased the sensitivity of cadmium and lead by 14% and 25%, respectively. The detection limits (n = 20, 3delta) were 0.03 microg L(-1) (0.36 pg) for cadmium and 0.57 microg L(-1) (6.8 pg) for lead. The performance of EC-THGA was acceptable up to 500 heating cycles. The reliability of the entire procedure was checked with the analysis of a lyophilized urine certified reference material. The found concentrations were in agreement with the recommended values (95% confidence level).

  16. Cloud point extraction for the determination of lead and cadmium in urine by graphite furnace atomic absorption spectrometry with multivariate optimization using Box Behnken design

    NASA Astrophysics Data System (ADS)

    Maranhão, Tatiane De A.; Martendal, Edmar; Borges, Daniel L. G.; Carasek, Eduardo; Welz, Bernhard; Curtius, Adilson J.

    2007-09-01

    Cloud point extraction (CPE) is proposed as a pre-concentration procedure for the determination of Pb and Cd in undigested urine by graphite furnace atomic absorption spectrometry (GF AAS). Aliquots of 0.5 mL urine were acidified with HCl and the chelating agent ammonium O,O-diethyl dithiophosphate (DDTP) was added along with the non-ionic surfactant Triton X-114 at the optimized concentrations. Phase separation was achieved by heating the mixture to 50 °C for 15 min. The surfactant-rich phase was analyzed by GF AAS, employing the optimized pyrolysis temperatures of 900 °C for Pb and 800 °C for Cd, using a graphite tube with a platform treated with 500 μg Ru as permanent modifier. The reagent concentrations for CPE (HCl, DDTP and Triton X-114) were optimized using a Box Behnken design. The response surfaces and the optimum values were very similar for aqueous solutions and for the urine samples, demonstrating that aqueous standards submitted to CPE could be used for calibration. Detection limits of 40 and 2 ng L- 1 for Pb and Cd, respectively, were obtained along with an enhancement factor of 16 for both analytes. Three control urine samples were analyzed using this approach, and good agreement was obtained at a 95% statistical confidence level between the certified and determined values. Five real samples have also been analyzed before and after spiking with Pb and Cd, resulting in recoveries ranging from 97 to 118%.

  17. Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry.

    PubMed

    Olmedo, P; Pla, A; Hernández, A F; López-Guarnido, O; Rodrigo, L; Gil, F

    2010-02-05

    For biological monitoring of heavy metal exposure in occupational toxicology, usually whole blood and urine samples are the most widely used and accepted matrix to assess internal xenobiotic exposure. Hair samples and saliva are also of interest in occupational and environmental health surveys but procedures for the determination of metals in saliva and hair are very scarce and to our knowledge there is no validation of a method to quantify Cr, Cd, Mn, Ni and Pb in four different human biological materials (whole blood, urine, saliva and axilary hair) by electrothermal atomization atomic absorption spectrometry (ETAAS). In the present study, quantification methods for the determination of Cr, Cd, Mn, Ni and Pb in whole blood, urine, saliva and axilary hair were validated according to the EU common standards. Pyrolisis and atomization temperatures have been determined. The main parameters evaluated were: detection and quantification limits, linearity range, repeatability, reproducibility, recovery and uncertainty. Accuracy of the methods was tested with the whole blood, urine and hair certified reference materials and recoveries of the spiked samples were acceptable ranged from 96.3 to 107.8%.

  18. A simple and selective approach for determination of trace Hg(II) using electromembrane extraction followed by graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Kamyabi, Mohammad Ali; Aghaei, Ali

    2017-02-01

    The present study proposes the determination of trace Hg(II) using electromembrane extraction followed by graphite furnace atomic absorption spectrometry (GFAAS). Hg(II) migrated from 5 mL of an aqueous donor phase across a thin layer of supported liquid membrane, immobilized inside pores of a hollow fiber, into 10 μL of an acidic acceptor phase present inside the lumen of the fiber. The final analysis of the extracted Hg(II) performed using GFAAS (350 °C and 1400 °C for the ashing and atomization temperatures, respectively). Under optimal conditions, Hg(II) was effectively extracted with recoveries in the range of 41-43%, which corresponded to enrichment factors in the range of 102-108. The calibration curve was investigated in the range of 0.5-10 μg/L and a good linearity was achieved with a coefficient factor of 0.998. Detection limit (3σ) was found to be 0.5 μg/L and repeatability for 5 replicate determinations of three different concentration level of Hg(II) were found to be within the range of 6.2-7.1%. The reliability of the proposed method was examined by analyzing different real waters samples.

  19. Improving accuracy in the quantitation of overlapping, asymmetric, chromatographie peaks by deconvolution: theory and application to coupled gas chromatography atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Johansson, M.; Berglund, M.; Baxter, D. C.

    1993-09-01

    Systematic errors in the measurement of overlapping asymmetric, Chromatographic peaks are observed using the perpendicular-drop and tangent-skimming algorithms incorporated in commercial integrators. The magnitude of such errors increases with the degree of tailing and differences in peak size, and was found to be as great as 80% for peak-area and 100% for peak-height measurements made on the smaller, second component of simulated, noise-free chromatograms containing peaks at a size ratio of 10 to 1. Initial deconvolution of overlapping peaks, by mathematical correction for asymmetry, leads to significant improvements in the accuracy of both peak-area and height measurements using the simple, perpendicular-drop algorithm. A comparison of analytical data for the separation and determination of three organolead species by coupled gas chromatography atomic absorption spectrometry using peak-height and area measurements also demonstrates the improved accuracy obtained following deconvolution. It is concluded that the deconvolution method described could be beneficial in a variety of Chromatographic applications where overlapping, asymmetric peaks are observed.

  20. Study of the roles of chemical modifiers in determining boron using graphite furnace atomic absorption spectrometry and optimization of the temperature profile during atomization.

    PubMed

    Yamamoto, Yuhei; Shirasaki, Toshihiro; Yonetani, Akira; Imai, Shoji

    2015-01-01

    The measurement conditions for determining boron using graphite furnace-atomic absorption spectrometry (GF-AAS) were investigated. Differences in the boron absorbance profiles were found using three different commercially available GF-AAS instruments when the graphite atomizers in them were not tuned. The boron absorbances found with and without adjusting the graphite atomizers suggested that achieving an adequate absorbance for the determination of boron requires a sharp temperature profile that overshoots the target temperature during the atomization process. Chemical modifiers that could improve the boron absorbance without the need for using coating agents were tested. Calcium carbonate improved the boron absorbance but did not suppress variability in the peak height. Improvement of boron absorbance was comparatively less using iron nitrate or copper nitrate than using calcium carbonate, but variability in the peak height was clearly suppressed using iron nitrate or copper nitrate. The limit of detection was 0.0026 mg L(-1) when iron nitrate was used. It appears that iron nitrate is a useful new chemical modifier for the quick and simple determination of boron using GF-AAS.

  1. Comparison of open microwave digestion and digestion by conventional heating for the determination of Cd, Cr, Cu and Pb in algae using transverse heated electrothermal atomic absorption spectrometry.

    PubMed

    Meeravali, N N; Kumar, S J

    2000-02-01

    A comparison between open microwave digestion and digestion by conventional heating was carried out for the determination of Cd, Cr, Cu, and Pb in two algae matrices using transverse heated electrothermal atomic absorption spectrometry (ETAAS). A SRM GBW 08504 cabbage was also analysed. These matrices were digested with HNO3, using a quartz vessel for microwave digestion and PFA vessel for digestion by conventional heating. Cd, Cu and Cr were determined without any modifier, while magnesium nitrate and ammonium phosphate mixed modifier was used for Pb. Results obtained by both the procedures were in good agreement with each other at 95% confidence level, and for SRM GBW 08504 cabbage the values agree well with the certified values. The limits of detection obtained were 0.0004, 0.060, 0.065 and 0.054 mg/kg for Cd, Cr, Cu, and Pb, respectively, using the microwave digestion process. The RSD for Cd was 10-15% and for the other elements 5-10%.

  2. Determination of ultra-trace amounts of prosthesis-related metals in whole blood using volumetric absorptive micro-sampling and tandem ICP - Mass spectrometry.

    PubMed

    Bolea-Fernandez, Eduardo; Phan, Kim; Balcaen, Lieve; Resano, Martín; Vanhaecke, Frank

    2016-10-19

    This paper reports on an evaluation of the suitability of a novel sample collection approach, volumetric absorptive micro-sampling (VAMS), in the context of the determination of ultra-trace concentrations of prosthesis-related metals (Al, Ti, V, Co, Cr, Ni, Sr and Zr) in whole blood. In a first phase, a simple dilute-and-shoot approach (100-fold dilution) followed by tandem ICP - mass spectrometry (ICP-MS/MS) analysis was developed for the accurate and sensitive determination of the target elements. The ICP-MS/MS method relies on the use of mass shift reactions proceeding when pressurizing the collision/reaction cell (CRC) with CH3F/He for dealing with spectral overlap. Limits of detection (LoDs) between 0.3 and 30 ng L(-1) were attained in a multi-element approach. The accuracy of the method was demonstrated via successful analysis of the reference materials Seronorm Whole Blood Levels 1 and 3, and real venous blood samples, spiked with the target elements at different concentration levels (5-50 μg L(-1)). Although the implementation of VAMS devices introduced contamination problems for Al, Cr and Ni, VAMS followed by ICP-MS/MS analysis shows potential for future real-life routine applications when assessing levels of Ti, V, Co, Sr and/or Zr.

  3. Fast arsenic speciation in water by on-site solid phase extraction and high-resolution continuum source graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Mihucz, Victor G.; Bencs, László; Koncz, Kornél; Tatár, Enikő; Weiszburg, Tamás; Záray, Gyula

    2017-02-01

    A method of high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS-GFAAS), combined with on-site separation/solid phase extraction (SPE) has been developed for the speciation of inorganic As (iAs) in geothermal and drinking water samples. The HR-CS-GFAAS calibration curves were linear up to 200 μg/L As, but using second order polynomial fitting, accurate calibration could be performed up to 500 μg/L. It has been demonstrated that sample pH should not be higher than 8 for an accurate speciation of As(V) with a recovery of ≈ 95%. Geothermal water had fairly high salt content (≈ 2200 mg/L) due to the presence of chlorides and sulfates at mg/L levels. Therefore, a two-fold dilution of these types of samples before SPE is recommended, especially, for total As determinations, when the As concentration is as high as 400 μg/L. For drinking water, sampled from public wells with records of As concentrations higher than the 10 μg/L in the past, the reduction of As contamination below the WHO's health limit value could be observed. However, the electrical conductivity was close to 2500 μS/cm, i.e., the guideline limit for drinking water, which was due to their higher chloride content. The proposed fit-for-purpose SPE-HR-CS-GFAAS method could be a candidate for screening drinking water quality.

  4. Solid phase extraction of mercury on sulfur loaded with N-(2-chloro benzoyl)-N'-phenylthiourea as a new adsorbent and determination by cold vapor atomic absorption spectrometry.

    PubMed

    Pourreza, N; Parham, H; Kiasat, A R; Ghanemi, K; Abdollahi, N

    2009-06-15

    This paper reports sulfur powder loaded with N-(2-chloro benzoyl)-N'-phenylthiourea as a new solid phase extractor for determination of ultra trace amounts of mercury. The mercury ions were retained on a mini-column filled with the solid phase at a flow rate of 16 mL min(-1). The retained Hg(II) ions were eluted with 3 mol L(-1) solution of HCl and measured by cold vapor atomic absorption spectrometry (CV-AAS). The mercury vapors were generated by a homemade Reaction Cell-Gas Liquid Separator (RC-GLS). The effect of different variables such as pH, sample flow rate, amounts of ligand loaded on sulfur and SnCl2 concentration was investigated. Calibration curve was linear in the range of 0.02-1.20 microg L(-1) with r=0.9991 (n=8). The limit of detection (LOD) based on three times the standard deviation of the blank was 0.012 and 0.003 microg L(-1) when 250 and 1000 mL sample volumes were used, respectively. The relative standard deviation (R.S.D.) for determination of 0.04 and 1.00 microg L(-1) of Hg(II) was 3.9 and 1.2% (n=8), respectively. The method was successfully applied to determine Hg(II) in water and marine samples.

  5. Feasibility of using in situ fusion for the determination of Co, Cr and Mn in Portland cement by direct solid sampling graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Intima, Danielle Polidorio; de Oliveira, Elisabeth; Oliveira, Pedro Vitoriano

    2009-06-01

    In situ fusion on the boat-type graphite platform has been used as a sample pretreatment for the direct determination of Co, Cr and Mn in Portland cement by solid sampling graphite furnace atomic absorption spectrometry (SS-GF AAS). The 3-field Zeeman technique was adopted for background correction to decrease the sensitivity during measurements. This strategy allowed working with up to 200 µg of sample. The in situ fusion was accomplished using 10 µL of a flux mixture 4.0% m/v Na 2CO 3 + 4.0% m/v ZnO + 0.1% m/v Triton® X-100 added over the cement sample and heated at 800 °C for 20 s. The resulting mould was completely dissolved with 10 µL of 0.1% m/v HNO 3. Limits of detection were 0.11 µg g - 1 for Co, 1.1 µg g - 1 for Cr and 1.9 µg g - 1 for Mn. The accuracy of the proposed method has been evaluated by the analysis of certified reference materials. The values found presented no statistically significant differences compared to the certified values (Student's t-test, p < 0.05). In general, the relative standard deviation was lower than 12% ( n = 5).

  6. Solidified floating organic drop microextraction (SFODME) for simultaneous separation/preconcentration and determination of cobalt and nickel by graphite furnace atomic absorption spectrometry (GFAAS).

    PubMed

    Bidabadi, Mahboubeh Shirani; Dadfarnia, Shayessteh; Shabani, Ali Mohammad Haji

    2009-07-15

    Solidified floating organic drop microextraction (SFODME), combined with graphite furnace atomic absorption spectrometry (GFAAS) was proposed for simultaneous separation/enrichment and determination of trace amounts of nickel and cobalt in surface waters and sea water. 1-(2-Pyridylazo)-2-naphthol (PAN) was used as chelating agent. The main parameters affecting the performance of SFODME, such as pH, concentration of PAN, extraction time, stirring rate, extraction temperature, sample volume and nature of the solvent were optimized. Under the optimum experimental conditions, a good relative standard deviation for six determination of 20 ng l(-1) of Co(II) and Ni(II) were 4.6 and 3.6%, respectively. An enrichment factor of 502 and 497 and detection limits of 0.4 and 0.3 ng l(-1) for cobalt and nickel were obtained, respectively. The procedure was applied to tap water, well water, river water and sea water, and accuracy was assessed through the analysis of certified reference water or recovery experiments.

  7. A novel ionic liquid/micro-volume back extraction procedure combined with flame atomic absorption spectrometry for determination of trace nickel in samples of nutritional interest.

    PubMed

    Dadfarnia, Shayesteh; Shabani, Ali Mohammad Haji; Bidabadi, Mahboubeh Shirani; Jafari, Abbas Ali

    2010-01-15

    A simple, highly sensitive and environment-friendly method for the determination of trace amount of nickel ion in different matrices is proposed. In the preconcentration step, the nickel from 10 mL of an aqueous solution was extracted into 500 microL of ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C(4)MIM][PF(6)], containing PAN as complexing agent. Subsequently, the PAN complex was back-extracted into 250 microL of nitric acid solution, and 100 microL of it was analyzed by flow injection flame atomic absorption spectrometry (FI-FAAS). The main parameter influencing the extraction and determination of nickel, such as pH, concentration of PAN, extraction time and temperature, ionic strength, and concentration of stripping acid solution, were optimized. An enhancement factor of 40.2 was achieved with 25 mL sample. The limit of detection (LOD) and quantification obtained under the optimum conditions were 12.5 and 41.0 microg L(-1), respectively. To validate the proposed methods two certified reference materials 681-I and BCR No. 288 were analyzed and the results were in good agreement with the certified values. The proposed method was successfully applied to determination of nickel in water samples, rice flour and black tea.

  8. Determination of cobalt, nickel, lead, bismuth and indium in ores, soils and related materials by atomic-absorption spectrometry after separation by xanthate extraction.

    PubMed

    Donaldson, E M

    1989-05-01

    A method for determining approximately 0.5, mug/g or more of cobalt, nickel and lead and approximately 3 mug/g or more of bismuth and indium in ores, soils and related materials is described. After sample decomposition and dissolution of the salts in dilute hydrochloric-tartaric acid solution, iron(III) is reduced with ascorbic acid and the resultant iron(II) is complexed with ammonium fluoride. Cobalt, nickel, lead, bismuth and indium are subsequently separated from iron, aluminium, zinc and other matrix elements by a triple chloroform extraction of their xanthate complexes at pH 2.00 +/- 0.05. After the removal of chloroform by evaporation and the destruction of the xanthates with nitric and perchloric acids, the solution is evaporated to dryness and the individual elements are ultimately determined in a 20% v/v hydrochloric acid medium containing 1000 mug/ml potassium by atomic-absorption spectrometry with an air-acetylene flame. Co-extraction of arsenic and antimony is avoided by volatilizing them as the bromides during the decomposition step. Small amounts of co-extracted molybdenum, iron and copper do not interfere.

  9. Dispersive liquid-liquid microextraction based on solidification of floating organic drop for preconcentration and determination of trace amounts of copper by flame atomic absorption spectrometry.

    PubMed

    Karadaş, Cennet; Kara, Derya

    2017-04-01

    A novel, simple, rapid, sensitive, inexpensive and environmentally friendly dispersive liquid-liquid microextraction method based on the solidification of a floating organic drop (DLLME-SFO) was developed for the determination of copper by flame atomic absorption spectrometry (FAAS). N-o-Vanillidine-2-amino-p-cresol was used as a chelating ligand and 1-undecanol was selected as an extraction solvent. The main parameters affecting the performance of DLLME-SFO, such as sample pH, volume of extraction solvent, extraction time, concentration of the chelating ligand, salt effect, centrifugation time and sample volume were investigated and optimized. The effect of interfering ions on the recovery of copper was also examined. Under the optimum conditions, the detection limit (3σ) was 0.93μgL(-1) for Cu using a sample volume of 20mL, yielding a preconcentration factor of 20. The proposed method was successfully applied to the determination of Cu in tap, river and seawater, rice flour and black tea samples as well as certified reference materials.

  10. Pharmacokinetics, absorption, and excretion of radiolabeled revexepride: a Phase I clinical trial using a microtracer and accelerator mass spectrometry-based approach

    PubMed Central

    Flach, Stephen; Croft, Marie; Ding, Jie; Budhram, Ron; Pankratz, Todd; Pennick, Mike; Scarfe, Graeme; Troy, Steven; Getsy, Jay

    2016-01-01

    Purpose Gastroesophageal reflux disease involves the reflux of gastric and/or duodenal content into the esophagus. Prokinetic therapies, such as the selective 5-hydroxytryptamine receptor 4 agonist revexepride, may aid gastric emptying. This Phase I study evaluated the pharmacokinetics and excretion pathways of [14C]revexepride in healthy individuals using a microtracer approach with accelerator mass spectrometry. Participants and methods Six healthy men received a single oral dose of 2 mg [14C]revexepride containing ~200 nCi of radioactivity; blood, urine, and fecal samples were collected over a 10-day period. Results Almost 100% of 14C was recovered: 38.2%±10.3% (mean ± standard deviation) was recovered in urine, and 57.3%±0.4% was recovered in feces. Blood cell uptake was low, based on the blood plasma total radioactivity ratio of 0.8. The mean revexepride renal clearance was 8.6 L/h, which was slightly higher than the typical glomerular filtration rate in healthy individuals. Time to reach maximal concentration was 1.75±1.17 hours (mean ± standard deviation). No safety signals were identified. Conclusion This study demonstrated that revexepride had rapid and moderate-to-good oral absorption. Excretion of radioactivity was completed with significant amounts in feces and urine. Renal clearance slightly exceeded the typical glomerular filtration rate, suggesting the involvement of active transportation in the renal tubules. PMID:27729771

  11. Determination of sulfur in crude oil using high-resolution continuum source molecular absorption spectrometry of the SnS molecule in a graphite furnace.

    PubMed

    Cadorim, Heloisa R; Pereira, Éderson R; Carasek, Eduardo; Welz, Bernhard; de Andrade, Jailson B

    2016-01-01

    An analytical method for the determination of sulfur, as the tin mono-sulfide (SnS) molecule, in crude oil using high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS) has been developed. The molecular absorbance of the SnS has been measured using the wavelength at 271.624 nm and the crude oil samples were prepared as micro-emulsions due to their high viscosity. Several chemical modifiers (Ir, Pd, Ru, Zr) were tested and palladium was chosen, because it exhibited the best performance. The heating program was optimized by comparing the pyrolysis and vaporization curves obtained for an aqueous sulfur standard and a micro-emulsion of a crude oil certified reference material (CRM). The optimum pyrolysis and vaporization temperatures were found to be 600 and 2000°C, respectively. The limit of detection and the characteristic mass using micro-emulsion analysis of crude oil samples were 5.8 and 13.3 ng S. Accuracy and precision of the method has been evaluated using two crude oil CRM (NIST 2721 and NIST 2722), showing good agreement with the informed or certified values.

  12. Sensitive determination of bismuth by flame atomic absorption spectrometry using atom trapping in a slotted quartz tube and revolatilization with organic solvent pulse

    NASA Astrophysics Data System (ADS)

    Kılınç, Ersin; Bakırdere, Sezgin; Aydın, Fırat; Ataman, O. Yavuz

    2012-07-01

    Sensitivity of flame atomic absorption spectrometry (FAAS) for Bi determination was improved by slotted quartz tube (SQT) that was used also for atom trapping (AT). The trapped analyte was released by aspirating a small volume of organic solvent after a reasonable analyte collection time. Sensitivity was improved by 2.9 times by SQT-FAAS and 256 times by SQT-AT-FAAS with respect to FAAS. Optimum trapping period was found to be 6.0 min (36.0 mL of solution). Limit of detection (LOD) for SQT-AT-FAAS was found to be 1.6 ng mL- 1. %RSD was calculated as 4.0% for five replicate measurements of 7.5 ng mL- 1 Bi by SQT-AT-FAAS. Accuracy of the method developed was checked by analyzing a standard reference material of simulated fresh water (NIST 1643e) and result found was in good agreement with the certified one. The method can be applied in any laboratory equipped with a flame AA spectrometer. The consumption of time and sample volume is fairly low and application is simple and easy.

  13. Direct extraction of lead (II) from untreated human blood serum using restricted access carbon nanotubes and its determination by atomic absorption spectrometry.

    PubMed

    Barbosa, Valéria Maria Pereira; Barbosa, Adriano Francisco; Bettini, Jefferson; Luccas, Pedro Orival; Figueiredo, Eduardo Costa

    2016-01-15

    Oxidized carbon nanotubes were covered with layers of bovine serum albumin to result in so-called restricted-access carbon nanotubes (RACNTs). This material can extract Pb(2+) ions directly from untreated human blood serum while excluding all the serum proteins. The RACNTs have a protein exclusion capacity of almost 100% and a maximum Pb(2+) adsorption capacity of 34.5mg g(-1). High resolution transmission electron microscopy, scanning transmission electron microscopy and energy dispersive spectroscopy were used to confirm the BSA layer and Pb(2+) adsorption sites. A mini-column filled with RACNTs was used in an on-line solid phase extraction system coupled to a thermospray flame furnace atomic absorption spectrometry. At optimized experimental conditions, the method has a detection limit as low as 2.1µg L(-1), an enrichment factor of 5.5, and inter- and intra-day precisions (expressed as relative standard deviation) of <8.1%. Recoveries of the Pb(2+) spiked samples ranged from 89.4% to 107.3% for the extraction from untreated human blood serum.

  14. Dendrimer pre-treatment enhances the skin permeation of chlorhexidine digluconate: Characterisation by in vitro percutaneous absorption studies and Time-of-Flight Secondary Ion Mass Spectrometry.

    PubMed

    Holmes, Amy M; Scurr, David J; Heylings, Jon R; Wan, Ka-Wai; Moss, Gary P

    2017-03-29

    Skin penetration and localisation of chlorhexidine digluconate (CHG) within the skin have been investigated in order to better understand and optimise the delivery using a nano polymeric delivery system of this topically-applied antimicrobial drug. Franz-type diffusion cell studies using in vitro porcine skin and tape stripping procedures were coupled with Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) to visualise the skin during various treatments with CHG and polyamidoamine dendrimers (PAMAM). Pre-treatment of the skin with PAMAM dendrimers significantly increased the amount and depth of permeation of CHG into the skin in vitro. The effect observed was not concentration dependant in the range 0.5-10mM PAMAM. This could be important in terms of the efficiency of treatment of bacterial infection in the skin. It appears that the mechanism of enhancement is due to the PAMAM dendrimer disrupting skin barrier lipid conformation or by occluding the skin surface. Franz-type diffusion cell experiments are complimented by the detailed visualisation offered by the semi-quantitative ToF-SIMS method which provides excellent benefits in terms of sensitivity and fragment ion specificity. This allows a more accurate depth profile of chlorhexidine permeation within the skin to be obtained and potentially affords the opportunity to map the co-localisation of permeants with skin structures, thus providing a greater ability to characterise skin absorption and to understand the mechanism of permeation, providing opportunities for new and more effective therapies.

  15. Determination of arsenobetaine, arsenocholine, and tetramethylarsonium cations in seafoods and human urine by high-performance liquid chromatography - thermochemical hydride generation - atomic absorption spectrometry

    SciTech Connect

    Momplaisir, G.M.; Blais, J.S.; Quinteiro, M.; Marshall, W.D. )

    1991-08-01

    A simple method was developed for the determination of arsonium compounds in edible marine tissues (lobster tail muscle, peeled deveined shrimp, cod fillet, and cod liver oil) and human urine. The homogenized marine tissue (5-10 g (or an equivalent weight of freeze-dried powder)) was blended with methanol; the extracts were combined and flash evaporated. Alternatively, urine (5 mL) was diluted with 50 mL of ethanol and placed in a dry ice-acetone bath for 20 min. Supernatant was separated from the resulting precipitate by centrifugation and flash evaporated. Residues from either sample type were resuspended in water, filtered through an anion exchanger, and acidified. The arsonium analytes were partitioned into liquefied phenol, which was diluted with diethyl ether and back extracted with water. The combined water extracts were taken to dryness, redissolved in methanol, concentrated to 1 mL, and separated on a cyanopropyl bonded-phase column using a methanolic mobile phase containing 19% (v/v) diethyl ether, 1% (v/v) acetic acid, 0.12% (v/v) triethylamine, and pricrylsulfonic acid (0.200 g/L). Analytes were detected on-line by thermochemical hydride generation-atomic absorption spectrometry. Recoveries from tissues or from urine which had been spiked at 0.1-3.4 {mu}g of cation/g of fresh weight were 83% or greater from each of the five sample types.

  16. Determination of Lead in Water Samples Using a New Vortex-Assisted, Surfactant-Enhanced Emulsification Liquid-Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry.

    PubMed

    Peng, Guilong; He, Qiang; Lu, Ying; Mmereki, Daniel; Pan, Weiliang; Tang, Xiaohui; Zhou, Guangming; Mao, Yufeng; Su, Xaioxuan

    2016-04-01

    A low toxic solvent-based vortex-assisted surfactant-enhanced emulsification liquid-liquid microextraction (LT-VSLLME) combined with graphite furnace atomic absorption spectrometry was developed for the extraction and determination of lead (Pb) in water samples. In the LT-VSLLME method, the extraction solvent was dispersed into the aqueous samples by the assistance of vortex agitator. Meanwhile, the addition of a surfactant, which acted as an emulsifier, could enhance the speed of the mass-transfer from aqueous samples to the extraction solvent. The influences of analytical parameters, including extraction solvent type and its volume, surfactant type and its volume, pH, concentration of chelating agent, salt effect and extraction time were investigated. Under the optimized conditions, a good relative standard deviation of 3.69% at 10 ng L(-1) was obtained. The calibration graph showed a linear pattern in the ranges of 5-30 ngL(-1), with a limit of detection of 0.76 ng L(-1). The linearity was obtained by five points in the concentration range of 5-30 ngL(-1). The enrichment factor was 320. The procedure was applied to wastewater and river water, and the accuracy was assessed through the analysis of the recovery experiments.

  17. Ultrasound-Assisted Emulsification Microextraction Based on Solidification Floating Organic Drop Trace Amounts of Manganese Prior to Graphite Furnace Atomic Absorption Spectrometry Determination

    PubMed Central

    Mohadesi, Alireza; Falahnejad, Masoumeh

    2012-01-01

    In the present study, an ultrasound-assisted emulsification microextraction based on solidification floating organic drop method is described for preconcentration of trace amounts of Mn (II). 2-(5-Bromo-2-pyridylazo)-5 diethylaminophenol was added to a solution of Mn+2 at ph = 10.0. After this, 1-undecanol was added to the solution as an extraction solvent, and solution was stirred. Several factors influencing the microextraction efficiency, such as pH, the amount of chelating agent, nature and volume of extraction solvent, the volume of sample solution, stirring rate, and extraction time were investigated and optimized. Then sample vial was cooled by inserting into an ice bath, and the solidified was transferred into a suitable vial for immediate melting. Finally the sample was injected into a graphite furnace atomic absorption spectrometry. Under the optimum condition the linear dynamic range was 0.50–10.0 ng mL−1 with a correlation coefficient of 0.9926, and the detection limit of 0.3 ng mL−1 was obtained. The enrichment factor was 160. The proposed method was successfully applied for separation and determination of manganese in sea, rain, tap, and river water samples. PMID:22645504

  18. Direct determination of arsenic and antimony in naphtha by electrothermal atomic absorption spectrometry with microemulsion sample introduction and iridium permanent modifier.

    PubMed

    Cassella, Ricardo J; Barbosa, Bruno Alberto R S; Santelli, Ricardo E; Rangel, Alessandra T

    2004-05-01

    This paper reports the determination of arsenic and antimony in naphtha by employing electrothermal atomic absorption spectrometry (ETAAS) as the analytical technique. In order to promote the direct determination of the analytes in the very volatile naphtha, the formation of a microemulsion with different surfactants (Triton X-100 and Brij-35) and different chemical modification strategies were tested. The results indicated that Triton X-100 is the best emulsification agent for naphtha in both As and Sb determination when it is employed at a concentration of 1% w/v in the microemulsion. Under these conditions, the microemulsion was stabile for at least 2 h. By using Brij-35 it was possible to achieve good stability only in the first 15 min. Among all chemical modification approaches investigated (Ir permanent modifier, W-Ir permanent modifier, and Pd modifier), the Ir permanent modifier provided better sensitivity for both analytes and allowed a higher pyrolysis temperature, which decreased the background signals at lower levels. Under the best conditions established in this work, an RSD of 4.6% (20 microg L(-1)) and a detection limit of 2.7 microg L(-1) were observed for arsenic. For antimony, an RSD of 4.0% (20 microg L(-1)) and a detection limit of 2.5 microg L(-1) were obtained. The accuracy of the procedure was assessed by analyzing spiked samples of naphtha from different origins.

  19. Determination of trace aluminum in biological and water samples by cloud point extraction preconcentration and graphite furnace atomic absorption spectrometry detection.

    PubMed

    Sang, Hongbo; Liang, Pei; Du, Dan

    2008-06-15

    A cloud point extraction (CPE) method for the preconcentration of trace aluminum prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS) has been developed. The CPE method is based on the complex of Al(III) with 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP), and then entrapped in non-ionic surfactant Triton X-114. PMBP was used not only as chelating reagent in CPE preconcentration, but also as chemical modifier in GFAAS determination. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of PMBP and Triton X-114, equilibration temperature and time, were investigated in detail. An enrichment factor of 37 was obtained for the preconcentration of Al(III) with 10 mL solution. Under the optimal conditions, the detection limit of this method for Al(III) is 0.09 ng mL(-1), and the relative standard deviation is 4.7% at 10 ng mL(-1) Al(III) level (n=7). The proposed method has been applied for determination of trace amount of aluminum in biological and water samples with satisfactory results.

  20. Improved determination of manganese in hair by use of a mini-autoclave and flameless atomic absorption spectrometry with Zeeman background correction: an evaluation in unexposed subjects

    SciTech Connect

    Guillard, O.; Brugier, J.C.; Piriou, A.; Menard, M.; Gombert, J.; Reiss, D.

    1984-10-01

    Motivated by the relatively wide range of values published hitherto, we offer a new, reliable method for determination of manganese in hair from unexposed human subjects. By using a mini-autoclave, we have developed a method that obviates loss of manganese during digestion and, thanks to use of a Teflon receptacle and rigorous methodology, contamination has been minimized. We used Zeeman flameless atomic absorption spectrometry, with the method of standard additions, for quantification. Within-run CVs for concentrations of Mn of 0.26 and 0.28 microgram/g of dry hair were 3.63 and 3.93%; the day-to-day CV for a Mn concentration of 0.29 microgram/g of dry hair was 5.84%. Mean (+/- SD) analytical recovery of Mn added to samples of hair was 104% (+/- 9.2%). The mean concentration of Mn found in the hair of 15 healthy unexposed subjects was 0.26 (+/- 0.05) microgram/g dry weight. This sensitive, reproducible procedure is suitable for use in analysis for traces of Mn in hair.

  1. Rapid leaching of Cr(VI) in soil with Na3PO4 in the determination of hexavalent chromium by electrothermal atomic absorption spectrometry.

    PubMed

    Mandiwana, Khakhathi L

    2008-01-15

    A method has been developed that leaches Cr(VI) selectively from soil samples. Hexavalent chromium was leached completely from soil with 0.01molL(-1) Na(3)PO(4). This was achieved by boiling the soil-reagent solution mixture for a period of 5min. The leached Cr(VI) was then quantified by electrothermal atomic absorption spectrometry (ET-AAS) after filtration of the sample solutions through Hydrophilic Millipore PVDF 0.45microm filter. Statistical evaluations indicated that the new developed method is reliable since neither its comparison with the established method nor the comparison of the sum of the concentrations of chromium species to that of the total concentration of chromium show any difference at 95% level of confidence. The spiking of soil samples with Cr(III) standards before pretreatment show that Cr(III) was not oxidized to Cr(VI) during leaching as the Cr(VI) content never increased. The detection limit established was 0.07microg g(-1), which is an improvement to that of the US EPA method 3060A by a factor of more than 500. The maximum concentrations of Cr(VI) found in soil samples collected around the new chromium mine was 8.0microg g(-1) and falls within acceptable level of 15microg g(-1) in accordance with the Italian Guidelines.

  2. Ultratrace determination of arsenic in water samples by electrothermal atomic absorption spectrometry after pre-concentration with Mg-Al-Fe ternary layered double hydroxide nano-sorbent.

    PubMed

    Abdolmohammad-Zadeh, Hossein; Jouyban, Abolghasem; Amini, Roghayeh

    2013-11-15

    A selective solid phase extraction method, based on nano-structured Mg-Al-Fe(NO3(-)) ternary layered double hydroxide as a sorbent, is developed for the pre-concentration of ultra-trace levels of arsenic (As) prior to determination by electrothermal atomic absorption spectrometry. It is found that both As(III) and As(V) could be quantitatively retained on the sorbent within a wide pH range of 4-12. Accordingly, the presented method is applied to determination of total inorganic As in aqueous solutions. Maximum analytical signal of As is achieved when the pyrolysis and atomization temperatures are close to 900 °C and 2300 °C, respectively. Several variables affecting the extraction efficiency including pH, sample flow rate, amount of nano-sorbent, elution conditions and sample volume are optimized. Under the optimized conditions, the limit of detection (3Sb/m) and the relative standard deviation are 4.6 pg mL(-1) and 3.9%, respectively. The calibration graph is linear in the range of 15.0-650 pg mL(-1) with a correlation coefficient of 0.9979, sorption capacity and pre-concentration factor are 8.68 mg g(-1) and 300, respectively. The developed method is validated by the analysis of a standard reference material (SRM 1643e) and is successfully applied to the determination of ultra-trace amounts of As in different water samples.

  3. Direct determination of silicon in powdered aluminium oxide by use of slurry sampling with in situ fusion graphite-furnace atomic-absorption spectrometry.

    PubMed

    Minami, H; Yoshida, T; Okutsu, K; Zhang, Q; Inoue, S; Atsuya, I

    2001-08-01

    A direct method for determination of silicon in powdered high-purity aluminium oxide samples, by slurry sampling with in situ fusion graphite-furnace atomic-absorption spectrometry (GF-AAS), has been established. A slurry sample was prepared by 10-min ultrasonication of a powdered sample in an aqueous solution containing both sodium carbonate and boric acid as a mixed flux. An appropriate portion of the slurry was introduced into a pyrolytic graphite furnace equipped with a platform. Silicon compounds to be determined and aluminium oxide were fused by the in situ fusion process with the flux in the furnace under optimized heating conditions, and the silicon absorbance was then measured directly. The calibration curve was prepared by use of a silicon standard solution containing the same concentration of the flux as the slurry sample. The accuracy of the proposed method was confirmed by analysis of certified reference materials. The proposed method gave statistically accurate values at the 95% confidence level. The detection limit was 3.3 microg g(-1) in solid samples, when 300 mg/20 mL slurry was prepared and a 10 microL portion of the slurry was measured. The precision of the determination (RSD for more than four separate determinations) was 14% and 2%, respectively, for levels of 10 and 100 microg g(-1) silicon in aluminium oxide.

  4. Validated method for the determination of platinum from a liposomal source (SPI-77) in human plasma using graphite furnace Zeeman atomic absorption spectrometry.

    PubMed

    Meerum Terwogt, J M; Tibben, M M; Welbank, H; Schellens, J H; Beijnen, J H

    2000-02-01

    A sensitive analytical method based on flameless atomic absorption spectrometry with Zeeman correction has been validated for the quantitative determination in human plasma of platinum originating from cisplatin in a liposomal source, SPI-77. The performance of the method was acceptable over a sample concentration range of 0. 125-1.25 micromol platinum/L and the lower limit of quantification was determined to be 1.25 micromol platinum/L in undiluted clinical samples. The performance data of the assay were investigated using both a calibration curve with carboplatin in plasma ultrafiltrate and diluted human plasma samples spiked with SPI-77. The recoveries, between-day and the within-day precisions of both methods of calibration were not significantly different allowing carboplatin ultrafiltrate calibration standards to be used to quantify platinum derived from SPI-77 in human plasma. Apparently, the liposomal formulation had no significant influence on the determination of platinum. The usefulness of the presented method was demonstrated in a phase I clinical and pharmacokinetic study. In addition, in vitro experiments were carried out to determine the distribution of SPI-77 in blood. The results indicated that platinum from SPI-77 mainly concentrates in plasma and that binding to and/or endocytosis in red blood cells is negligible.

  5. Evaluation of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry for direct determination of chromium in medicinal plants

    NASA Astrophysics Data System (ADS)

    Virgilio, Alex; Nóbrega, Joaquim A.; Rêgo, Jardes F.; Neto, José A. Gomes

    2012-12-01

    A method for Cr determination in medicinal plants using direct solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry was developed. Modifiers were dispensable. Pyrolysis and atomization temperatures were 1500 °C and 2400 °C, respectively. Slopes of calibration curves (50-750 pg Cr, R2 > 0.999) using aqueous and solid standards coincides in 96%, indicated feasibility of aqueous calibration for solid sampling of medicinal plants. Accuracy was checked by analysis of four plant certified reference materials. Results were in agreement at 95% confidence level with certified and non-certified values. Ten samples of medicinal plants were analyzed and Cr contents were in the 1.3-17.7 μg g- 1 Cr range. The highest RSD (n = 5) was 15.4% for the sample Melissa officinalis containing 13.9 ± 2.1 μg g- 1 Cr. The limit of detection was 3.3 ng g- 1 Cr.

  6. Preparation of modified magnetic nanoparticles as a sorbent for the preconcentration and determination of cadmium ions in food and environmental water samples prior to flame atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Mirabi, Ali; Dalirandeh, Zeinab; Rad, Ali Shokuhi

    2015-05-01

    A new method has been developed for the separation/preconcentration of trace level cadmium ions using diphenyl carbazone/sodium dodecyl sulfate immobilized on magnetic nanoparticle Fe3O4 as a new sorbent SPE and their determination by flame atomic absorption spectrometry (FAAS). Synthesized nanoparticle was characterized by scanning electron microscope (SEM) and transmission electron microscope (TEM). Various influencing parameters on the separation and preconcentration of trace level cadmium ions such as, pH value, amount of nanoparticles, amount of diphenyl carbazone, condition of eluting solution, the effects of matrix ions were examined. The cadmium ions can be eluted from the modified magnetic nanoparticle using 1 mol L-1 HCl as a desorption reagent. The detection limit of this method for cadmium was 3.71 ng ml-1 and the R.S.D. was 0.503% (n=6). The advantages of this new method include rapidity, easy preparation of sorbents and a high concentration factor. The proposed method has been applied to the determination of Cd ions at trace levels in real samples such as, green tea, rice, tobacco, carrot, lettuce, ginseng, spice, tap water, river water, sea water with satisfactory results.

  7. Magnetic stirrer induced dispersive ionic-liquid microextraction for the determination of vanadium in water and food samples prior to graphite furnace atomic absorption spectrometry.

    PubMed

    Naeemullah; Kazi, Tasneem Gul; Tuzen, Mustafa

    2015-04-01

    A new dispersive liquid-liquid microextraction, magnetic stirrer induced dispersive ionic-liquid microextraction (MS-IL-DLLME) was developed to quantify the trace level of vanadium in real water and food samples by graphite furnace atomic absorption spectrometry (GFAAS). In this extraction method magnetic stirrer was applied to obtained a dispersive medium of 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6] in aqueous solution of (real water samples and digested food samples) to increase phase transfer ratio, which significantly enhance the recovery of vanadium - 4-(2-pyridylazo) resorcinol (PAR) chelate. Variables having vital role on desired microextraction methods were optimised to obtain the maximum recovery of study analyte. Under the optimised experimental variables, enhancement factor (EF) and limit of detection (LOD) were achieved to be 125 and 18 ng L(-1), respectively. Validity and accuracy of the desired method was checked by analysis of certified reference materials (SLRS-4 Riverine water and NIST SRM 1515 Apple leaves). The relative standard deviation (RSD) for 10 replicate determinations at 0.5 μg L(-1) of vanadium level was found to be <5.0%. This method was successfully applied to real water and acid digested food samples.

  8. One-step displacement dispersive liquid-liquid microextraction coupled with graphite furnace atomic absorption spectrometry for the selective determination of methylmercury in environmental samples.

    PubMed

    Liang, Pei; Kang, Caiyan; Mo, Yajun

    2016-01-01

    A novel method for the selective determination of methylmercury (MeHg) was developed by one-step displacement dispersive liquid-liquid microextraction (D-DLLME) coupled with graphite furnace atomic absorption spectrometry. In the proposed method, Cu(II) reacted with diethyldithiocarbamate (DDTC) to form Cu-DDTC complex, which was used as the chelating agent instead of DDTC for the dispersive liquid-liquid microextraction (DLLME) of MeHg. Because the stability of MeHg-DDTC is higher than that of Cu-DDTC, MeHg can displace Cu from the Cu-DDTC complex and be preconcentrated in a single DLLME procedure. MeHg could be extracted into the extraction solvent phase at pH 6 while Hg(II) remained in the sample solution. Potential interference from co-existing metal ions with lower DDTC complex stability was largely eliminated without the need of any masking reagent. Under the optimal conditions, the limit of detection of this method was 13.6ngL(-1) (as Hg), and an enhancement factor of 81 was achieved with a sample volume of 5.0mL. The proposed method was successfully applied for the determination of trace MeHg in some environmental samples with satisfactory results.

  9. Investigation of chemical modifiers for the direct determination of arsenic in fish oil using high-resolution continuum source graphite furnace atomic absorption spectrometry.

    PubMed

    Pereira, Éderson R; de Almeida, Tarcísio S; Borges, Daniel L G; Carasek, Eduardo; Welz, Bernhard; Feldmann, Jörg; Campo Menoyo, Javier Del

    2016-04-01

    High-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) has been applied for the development of a method for the determination of total As in fish oil samples using direct analysis. The method does not use any sample pretreatment, besides dilution with 1-propanole, in order to decrease the oil viscosity. The stability and sensitivity of As were evaluated using ruthenium and iridium as permanent chemical modifiers and palladium added in solution over the sample. The best results were obtained with ruthenium as the permanent modifier and palladium in solution added to samples and standard solutions. Under these conditions, aqueous standard solutions could be used for calibration for the fish oil samples diluted with 1-propanole. The pyrolysis and atomization temperatures were 1400 °C and 2300 °C, respectively, and the limit of detection and characteristic mass were 30 pg and 43 pg, respectively. Accuracy and precision of the method have been evaluated using microwave-assisted acid digestion of the samples with subsequent determination by HR-CS GF AAS and ICP-MS; the results were in agreement (95% confidence level) with those of the proposed method.

  10. Optimization of high-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of selected trace elements in whole blood samples.

    PubMed

    Wójciak-Kosior, Magdalena; Szwerc, Wojciech; Strzemski, Maciej; Wichłacz, Zoltan; Sawicki, Jan; Kocjan, Ryszard; Latalski, Michał; Sowa, Ireneusz

    2017-04-01

    Trace analysis plays an important role in medicine for diagnosis of various disorders; however, the appropriate sample preparation is required mostly including mineralization. Although graphite furnace atomic absorption spectrometry (GF AAS) allows the investigation of biological samples such as blood, serum, and plasma without this step, it is rarely used for direct analysis because the residues of the rich organic matrix inside the furnace are difficult to remove and this may cause spectral/matrix interferences and decrease the lifetime of the graphite tube. In our work, the procedure for determination of Se, Cr, Mn, Co, Ni, Cd and Pb with the use of the high resolution continuum source GF-AAS technique in whole blood samples with minimum sample pre-treatment was elaborated. The pyrolysis and atomization temperature as well as the time of signal integration were optimized to obtain the highest intensity and repeatability of the analytical signal. Moreover, due to the apparatus modification, an additional step was added in the for graphite furnace temperature program with minimal argon flow and maximal flow of air during pyrolysis stage to increase the oxidative condition for better matrix removal. The accuracy and precision of the optimized method was verified using certified reference material (CRM) Seronorm Trace Elements Whole Blood L-1 and the developed method was applied for trace analysis of blood samples from volunteer patients of the Orthopedics Department.

  11. Ionic liquid-based extraction followed by graphite-furnace atomic absorption spectrometry for the determination of trace heavy metals in high-purity iron metal.

    PubMed

    Matsumiya, Hiroaki; Kato, Tatsuya; Hiraide, Masataka

    2014-02-01

    The analysis of high-purity materials for trace impurities is an important and challenging task. The present paper describes a facile and sensitive method for the determination of trace heavy metals in high-purity iron metal. Trace heavy metals in an iron sample solution were rapidly and selectively preconcentrated by the extraction into a tiny volume of an ionic liquid [1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide] for the determination by graphite-furnace atomic absorption spectrometry (GFAAS). A nitrogen-donating neutral ligand, 2,4,6-tris(2-pyridyl)-1,3,5-triazine (TPTZ), was found to be effective in the ionic liquid-based selective extraction, allowing the nearly complete (~99.8%) elimination of the iron matrix. The combination with the optimized GFAAS was successful. The detectability reached sub-μg g(-1) levels in iron metal. The novel use of TPTZ in ionic liquid-based extraction followed by GFAAS was successfully applied to the determination of traces of Co, Ni, Cu, Cd, and Pb in certified reference materials for high-purity iron metal.

  12. Determination of macro and trace elements in multivitamin dietary supplements by high-resolution continuum source graphite furnace atomic absorption spectrometry with slurry sampling.

    PubMed

    Krawczyk, Magdalena

    2014-01-01

    In this research, three different commercially available multivitamin dietary supplements were analyzed by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) with slurry sampling. The concentrations of Cr, Cu, Fe, Mn, and Se were determined and compared to the amounts stated by producers. The safety of multivitamin dietary supplements depends on various factors including the manufacturing process and the purity and origins of the raw ingredients. For this reason, this research determined concentrations of several toxic elements (As, Cd, and Pb). Microwave-assisted high pressure Teflon bomb digestion was used to determine total amounts of elements in samples. Samples were prepared as slurries at a concentration of 0.1% (m/v) for macro elements (Cr, Cu, Fe, Mn, and Se) and at a concentration of % (m/v) for trace elements (As, Cd, and Pb) in acidic media (3M HNO3). The influence of acid concentration, Triton X-100 addition, sonication time, and sonication power on absorbance was investigated. The accuracy of this method was validated by analyses of NRCC LUTS-1 (Lobster hepatopancreas), NRCC DORM-1 (Dogfish Muscle), NRCC DOLT-2 (Dogfish Liver), NBS SRM 1570 (Spinach Leaves) and NBS SRM 1573 (Tomato Leaves) certified reference materials. The measured elements contents in these reference materials (except NRCC DOLT-2) were in satisfactory agreement with the certified values according to the t-test for a 95% confidence level.

  13. Validation and application of cavity-enhanced, near-infrared tunable diode laser absorption spectrometry for measurements of methane carbon isotopes at ambient concentrations.

    PubMed

    Mortazavi, Behzad; Wilson, Benjamin J; Dong, Feng; Gupta, Manish; Baer, Doug

    2013-10-15

    Methane is an effective greenhouse gas but has a short residence time in the atmosphere, and therefore, reductions in emissions can alleviate its greenhouse gas warming effect within a decadal time frame. Continuous and high temporal resolution measurements of methane concentrations and carbon isotopic ratios (δ(13)CH4) can inform on mechanisms of formation, provide constraints on emissions sources, and guide future mitigation efforts. We describe the development, validation, and deployment of a cavity-enhanced, near-infrared tunable diode laser absorption spectrometry system capable of quantifying δ(13)CH4 at ambient methane concentrations. Laboratory validation and testing show that the instrument is capable of operating over a wide dynamic range of methane concentration and provides a measurement precision for δ(13)CH4 of better than ± 0.5 ‰ (1σ) over 1000 s of data averaging at ambient methane concentrations. The analyzer is accurate to better than ± 0.5 ‰, as demonstrated by measurements of characterized methane/air samples with minimal dependence (<1 ‰) of measured carbon isotope ratio on methane concentration. Deployment of the instrument at a marsh over multiple days demonstrated how methane fluxes varied by an order of magnitude over 2 day deployment periods, and showed a 17 ‰ variability in δ(13)CH4 of the emitted methane during the growing season.

  14. [Direct determination of lead and cadmium in soil by slurry-sampling graphite furnace atomic absorption spectrometry using matrix modification technique].

    PubMed

    Sun, Han-Wen; Wen, Xiao-Hua; Liang, Shu-Xuan

    2006-05-01

    A method for the direct determination of lead and cadmium in soil by slurry-sampling graphite furnace-atomic absorption spectrometry using NH4 H2 PO4 as matrix modifier was developed. The effects of slurry stability, particle size of sample, matrix modifiers, ashing temperature, atomization temperature and common coexistent components on the signal intensities of lead and cadmium were investigated. The apparent activation energies of lead and cadmium were measured based on the linear relationship between the logarithm value of atomization peak time and atomization temperature. The mechanism of matrix modification was discussed. Under optimized conditions, the detection limit was 9.05 x 10(-10) g x mL(-1) for Pb and 1.76 x 10(-11) g x mL(-1) for Cd. The recoveries were in the range of 91%-97% for Pb and 93%-109% for Cd. The relative standard deviations were in the range of 4.2%-7.8%.

  15. Mercury(II) and methyl mercury determinations in water and fish samples by using solid phase extraction and cold vapour atomic absorption spectrometry combination.

    PubMed

    Tuzen, Mustafa; Karaman, Isa; Citak, Demirhan; Soylak, Mustafa

    2009-07-01

    A method has been developed for mercury(II) and methyl mercury speciation on Staphylococcus aureus loaded Dowex Optipore V-493 micro-column in the presented work, by using cold vapour atomic absorption spectrometry. Selective and sequential elution with 0.1 molL(-1) HCl for methyl mercury and 2 molL(-1) HCl for mercury(II) were performed at the pH range of 2-6. Optimal analytical conditions including pH, amounts of biosorbent, sample volumes were investigated. The detection limits of the analytes were 2.5 ngL(-1) for Hg(II) and 1.7 ngL(-1) for methyl mercury. The capacity of biosorbent for mercury(II) and methyl mercury was 6.5 and 5.4 mgg(-1), respectively. The validation of the presented procedure is performed by the analysis of standard reference material. The speciation procedure established was successfully applied to the speciation of mercury(II) and methyl mercury in natural water and microwave digested fish samples.

  16. The use of silver nanoparticles as an effective modifier for the determination of arsenic and antimony by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Gunduz, S.; Akman, S.; Baysal, A.; Kahraman, M.

    2010-04-01

    Silver nanoparticles (AgNPs) were proposed as a new chemical modifier for the elimination of interferences when determining arsenic and antimony in aqueous NaCl or Na 2SO 4 solutions and in sea-water by electrothermal atomic absorption spectrometry. For this purpose, the AgNPs were prepared simply by reducing silver nitrate with sodium citrate. The effects of pyrolysis and atomization temperatures and the amounts of interferents and modifiers on the sensitivities of these elements were investigated. In the presence of the proposed modifier, a pyrolysis temperature of at least 1100 °C for arsenic and 900 °C for antimony could be applied without the loss of analytes, and the interferences were greatly reduced to allow for interference-free determination. The detection limits ( N = 10, 3 σ) for arsenic and antimony were 0.022 ng and 0.046 ng, respectively. AgNPs are cheaper and more available compared to many other modifiers. No background was detected, and the blank values were negligible.

  17. Speciation of very low amounts of arsenic and antimony in waters using dispersive liquid-liquid microextraction and electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Rivas, Ricardo E.; López-García, Ignacio; Hernández-Córdoba, Manuel

    2009-04-01

    A new procedure for the determination of inorganic arsenic (III,V) and antimony (III,V) in water samples by dispersive liquid-liquid micro extraction separation and electrothermal atomic absorption spectrometry (ETAAS) is presented. At pH 1, As(III) and Sb(III) are complexed with ammonium pyrrolidine dithiocarbamate and extracted into the fine droplets formed when mixing carbon tetrachloride (extraction solvent), methanol (disperser solvent) and the sample solution. After extraction, the phases are separated by centrifugation, and As(III) and Sb(III) are determined in the organic phase. As(V) and Sb(V) remain in the aqueous layer. Total inorganic As and Sb are determined after the reduction of the pentavalent forms with sodium thiosulphate. As(V) and Sb(V) are calculated by difference. The detection limits are 0.01 and 0.05 µg L - 1 for As(III) and Sb(III), respectively, with an enrichment factor of 115. The relative standard deviation is in the 2.9-4.5% range. The procedure has been applied to the speciation of inorganic As and Sb in bottled, tap and sea water samples with satisfactory results.

  18. Use of slurry sampling for the direct determination of zinc in yogurt by high resolution-continuum source flame atomic absorption spectrometry.

    PubMed

    Brandao, Geovani C; de Jesus, Raildo M; da Silva, Erik G P; Ferreira, Sergio L C

    2010-06-15

    This paper presents an analytical procedure for the direct determination of zinc in yogurt employing sampling slurry and high resolution-continuum source flame atomic absorption spectrometry (HR-CS FAAS). The step optimization established the experimental conditions of: 2.0molL(-1) hydrochloric acid, a sonication time of 20min and a sample mass of 1.0g for a slurry volume of 25mL. This method allows the determination of zinc with a limit of quantification of 0.32microgg(-1). The precision expressed as relative standard deviation (RSD) were 0.82 and 2.08% for yogurt samples containing zinc concentrations of 4.85 and 2.49microgg(-1), respectively. The accuracy was confirmed by the analysis of a certified reference material of non-fat milk powder furnished by the National Institute of Standard and Technology. The proposed method was applied for the determination of zinc in seven yogurt samples. The zinc content was varied from 2.19 to 4.85microgg(-1). These results agreed with those reported in the literature. The samples were also analyzed after acid digestion and zinc determination by FAAS. No statistical difference was observed between the results obtained by both of the procedures performed.

  19. Development of a flow system for the determination of cadmium in fuel alcohol using vermicompost as biosorbent and flame atomic absorption spectrometry.

    PubMed

    Bianchin, Joyce Nunes; Martendal, Edmar; Mior, Renata; Alves, Vanessa Nunes; Araújo, Cleide Sandra Tavares; Coelho, Nívia Maria Melo; Carasek, Eduardo

    2009-04-30

    In this study a method for the determination of cadmium in fuel alcohol using solid-phase extraction with a flow injection analysis system and detection by flame atomic absorption spectrometry was developed. The sorbent material used was a vermicompost commonly used as a garden fertilizer. The chemical and flow variables of the on-line preconcentration system were optimized by means of a full factorial design. The selected factors were: sorbent mass, sample pH, buffer concentration and sample flow rate. The optimum extraction conditions were obtained using sample pH in the range of 7.3-8.3 buffered with tris(hydroxymethyl)aminomethane at 50 mmol L(-1), a sample flow rate of 4.5 mL min(-1) and 160 mg of sorbent mass. With the optimized conditions, the preconcentration factor, limit of detection and sample throughput were estimated as 32 (for preconcentration of 10 mL sample), 1.7 microg L(-1) and 20 samples per hour, respectively. The analytical curve was linear from 5 up to at least 50 microg L(-1), with a correlation coefficient of 0.998 and a relative standard deviation of 2.4% (35 microg L(-1), n=7). The developed method was successfully applied to spiked fuel alcohol, and accuracy was assessed through recovery tests, with recovery ranging from 94% to 100%.

  20. Ultrasound-assisted ion-pair dispersive liquid-liquid microextraction of trace amounts of lead in water samples prior to graphite furnace atomic absorption spectrometry determination.

    PubMed

    Afzali, Daryoush; Mohadesi, Ali Reza; Falahnejad, Masoumeh; Bahadori, Behnoosh

    2013-01-01

    A new ion-pair dispersive liquid-liquid microextraction method is described for separation and preconcentration of trace amounts of lead in different water samples. Graphite furnace atomic absorption spectrometry was used for determination of lead. The ion association complex between lead and iodide ions that forms is PbI4(-2)-tetradecyl-dimethylbenzylammonium, which is extracted into fine droplets of chlorobenzene. In order to reach the optimized experimental conditions, the influence of different parameters, such as concentration of KI, nature and volume of extraction solvents, pH effect, extraction time, and the period and speed of sonication and centrifugation, were optimized. The LOD was 0.08 ng/mL and the linear dynamic range was 0.20-8.0 ng/mL in initial solution with a correlation coefficient of 0.9985. Under the optimum conditions, the enrichment factor was 555.5. The proposed method was successfully applied for separation and determination of lead in sea, rain, river, and drinking water samples.

  1. Automatic kinetic bioaccessibility assay of lead in soil environments using flow-through microdialysis as a front end to electrothermal atomic absorption spectrometry.

    PubMed

    Cocovi-Solberg, David J; Rosende, Maria; Miró, Manuel

    2014-06-03

    In-line microdialysis is in this work hyphenated to electrothermal atomic absorption spectrometry via a dedicated flow-based interface for monitoring the batchwise leaching test endorsed by the Standards, Measurements and Testing Program (SM&T) of the European Commission. The bioaccessible pool of lead in soils is measured using 0.43 mol/L AcOH as extractant. The proposed method allows to gain knowledge of leaching kinetics at real-time, simplify the overall procedure by accurate detection of steady-state conditions and overcome sample filtration or centrifugation. Soil leachates were automatically sampled at specified timeframes (e.g, every 20 or 80 min), processed in an external container (where dilution can be applied at will) and further injected into the atomizer. The method was experimentally validated by comparison of in situ microdialysis sampling results with in-line microfiltration in two soils of varying physicochemical properties. A mathematical framework was used for discrimination of different metal fractions (that is, readily mobilizable against slowly mobilizable lead) and also for estimating the total extractable lead under actual steady-state conditions. We have demonstrated that bioaccessibility tests lasting 16 h as endorsed by SM&T might not suffice for ascertainment of maximum (steady-state) bioaccessibility of lead in terrestrial environments as demanded in risk assessment programs.

  2. Validation of a digestion system using a digester block/cold finger system for the determination of lead in vegetable foods by electrothermal atomic absorption spectrometry.

    PubMed

    De Jesus, Robson M; Junior, Mario M S; Matos, Geraldo D; Dos Santos, Ana M P; Ferreira, Sérgio L C

    2011-01-01

    This paper presents the validation of a system for sample digestion using a digester block/cold finger to determine the lead content in vegetables by electrothermal atomic absorption spectrometry (ETAAS). After mineralization, lead contents were determined by ETAAS using a calibration curve based on aqueous standards prepared in 2.60 M nitric acid solutions containing 5 microg ammonium phosphate as chemical modifier. A pyrolysis temperature of 900 degrees C and atomization temperature of 2000 degrees C were used. This method allowed the determination of lead with a characteristic mass of 35 pg; LOD and LOQ of 0.6 and 2 nglg, respectively, were found. The precision was investigated in terms of reproducibility and repeatability. Reproducibility was estimated by analysis of nine different portions of a certified reference material (CRM) of spinach leaves, and the repeatability was determined through the analysis of nine aliquots of the same solution. The reproducibility and repeatability were found to be 4.27 and 2.94% RSD, respectively. The accuracy was confirmed by analysis of whole meal flour, spinach leaves, and orchard leaves CRMs, all furnished by the National Institute of Standards and Technology. Lead contents were measured using the newly developed technique in 11 different potato samples. The lead contents ranged from 12.80 to 69.27 ng/g, with an average value of 28.59 ng/g. These values were in agreement with data reported in the literature.

  3. Development of an ultrasonic slurry sampling method for the determination of Cu and Mn in antibiotic tablets by electrothermal atomic absorption spectrometry.

    PubMed

    de Paula, Carlos Eduardo R; Caldas, Luiz Fernando S; Brum, Daniel M; Cassella, Ricardo J

    2012-07-01

    A new method is described for simple, efficient and rapid determination of Cu and Mn in tablets of antibiotics (ciprofloxacin and cephalexin) by electrothermal atomic absorption spectrometry (ETAAS) using slurry sampling. In order to optimize the procedure, several variables that could affect the performance of the method were investigated. In the best conditions, the tablets could be analyzed by introducing into the graphite tube 20 μl of a slurry prepared with approximately 90-100mg of the sample and 2 ml of a solution containing 5% m/v of Triton X-114 and 2.8 M of HNO(3). Before the introduction, the slurries were sonicated for 15 min at 40% of amplitude (130 W maximum power) with an ultrasonic probe. The developed method was applied in the determination of Cu and Mn in four samples, and the results were compared with those obtained by focused microwave acid digestion with aqua regia (1:3 mixture of HNO(3):HCl). There was no statistical difference between the obtained values at 95% confidence level when a paired Student t-test was applied.

  4. Comparative determination of Ba, Cu, Fe, Pb and Zn in tea leaves by slurry sampling electrothermal atomic absorption and liquid sampling inductively coupled plasma atomic emission spectrometry.

    PubMed

    Mierzwa, J; Sun, Y C; Chung, Y T; Yang, M H

    1998-12-01

    The comparative determination of barium, copper, iron, lead and zinc in tea leaf samples by two atomic spectrometric techniques is reported. At first, slurry sampling electrothermal atomization atomic absorption spectrometry (ETAAS) was applied. The results of Ba and Pb determination were calculated using the method of standard additions, and results of Cu, Fe and Zn from the calibration graphs based on aqueous standards. These results were compared with the results obtained after microwave-assisted wet (nitric+hydrochloric+hydrofluoric acids) digestion in closed vessels followed by inductively coupled plasma-atomic emission spectrometric (ICP-AES) determination with the calibration by means of aqueous standards. The exception was lead determined after a wet digestion procedure by ETAAS. The accuracy of the studied methods was checked by the use of the certified reference material Tea GBW-07605. The recoveries of the analytes varied in the range from 91 to 99% for slurry sampling ETAAS, and from 92.5 to 102% for liquid sampling ICP-AES. The advantages of slurry sampling ETAAS method are simplicity of sample preparation and very good sensitivity. Slurry sampling ETAAS method is relatively fast but if several elements must be determined in one sample, the time of the whole microwave-assisted digestion procedure and ICP-AES determination will be shorter. However, worse detection limits of ICP-AES must also be taken into the consideration in a case of some analytes.

  5. Study of ammonium molybdate to minimize the phosphate interference in the selenium determination by electrothermal atomic absorption spectrometry with deuterium background correction

    NASA Astrophysics Data System (ADS)

    Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio; Bermejo-Barrera, Adela

    2002-02-01

    The use of ammonium molybdate to minimize the phosphate interference when measuring selenium by electrothermal atomic absorption spectrometry (ETAAS) with deuterium background correction was evaluated. Ammonium molybdate did not produce a selenium thermal stabilization; however, the presence of ammonium molybdate decreased the phosphate interference. The study was carried out with mussel acid digests and mussel slurries. Pd-Mg(NO 3) 2 was used as a chemical modifier at optimum concentrations of 300 and 250 mg l -1, respectively, yielding optimum pyrolysis and atomization temperatures of 1200 and 2100 °C, respectively. A yellow solid (ammonium molybdophosphate) was obtained when adding ammonium molybdate to mussel acid digest solutions. This precipitate can be removed after centrifugation prior to ETAAS determination. Additionally, studies on the sampling of the solid ammonium molybdophosphate (AMP) together with the liquid phase, as a slurry, were also developed. The volatilization of the solid AMP was not reached at temperatures lower than 2500 °C. By this way, phosphate, as AMP, is not present in the vapor phase at the atomization temperature (2100 °C), yielding a reduction of the spectral interference by phosphate. The proposed method was validated analyzing three reference materials of marine origin (DORM-1, DOLT-1 and TORT-1). Good agreement with the certified selenium contents was reached for all cases.

  6. Separation/preconcentration and determination of vanadium with dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFO) and electrothermal atomic absorption spectrometry.

    PubMed

    Asadollahi, Tahereh; Dadfarnia, Shayessteh; Shabani, Ali Mohammad Haji

    2010-06-30

    A novel dispersive liquid-liquid microextraction based on solidification of floating organic drop (DLLME-SFO) for separation/preconcentration of ultra trace amount of vanadium and its determination with the electrothermal atomic absorption spectrometry (ETAAS) was developed. The DLLME-SFO behavior of vanadium (V) using N-benzoyl-N-phenylhydroxylamine (BPHA) as complexing agent was systematically investigated. The factors influencing the complex formation and extraction by DLLME-SFO method were optimized. Under the optimized conditions: 100 microL, 200 microL and 25 mL of extraction solvent (1-undecanol), disperser solvent (acetone) and sample volume, respectively, an enrichment factor of 184, a detection limit (based on 3S(b)/m) of 7 ng L(-1) and a relative standard deviation of 4.6% (at 500 ng L(-1)) were obtained. The calibration graph using the preconcentration system for vanadium was linear from 20 to 1000 ng L(-1) with a correlation coefficient of 0.9996. The method was successfully applied for the determination of vanadium in water and parsley.

  7. Determination of lead in medicinal plants by high-resolution continuum source graphite furnace atomic absorption spectrometry using direct solid sampling.

    PubMed

    Figuerêdo Rêgo, Jardes; Virgilio, Alex; Nóbrega, Joaquim A; Gomes Neto, José A

    2012-10-15

    A procedure is proposed for Pb determination in medicinal plants by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) using direct solid sampling. Among Pd(NO(3))(2), Pd/Mg(NO(3))(2), NH(4)H(2)PO(4) and the W-coated platform tested as chemical modifiers, Pd(NO(3))(2) presented the best performance. Calibration plots (10-1000 pg Pb) with regression coefficients better than 0.999 were typically obtained. Accuracy was checked for Pb determination in five plant certified reference materials. Results were in agreement with reference values at a 95% confidence level (paired t-test). Medicinal plant samples were analyzed by the proposed procedure and line-source GF AAS using slurry sampling as a comparative technique. The RSD was 10% (n=3) for a sample containing 0.88 μg g(-1) Pb. The limit of quantification (dry mass) was 0.024 μg g(-1). The contents of Pb in medicinal plant samples varied in the 0.30-1.94 μg g(-1) range.

  8. Novel ion imprinted magnetic mesoporous silica for selective magnetic solid phase extraction of trace Cd followed by graphite furnace atomic absorption spectrometry detection

    NASA Astrophysics Data System (ADS)

    Zhao, Bingshan; He, Man; Chen, Beibei; Hu, Bin

    2015-05-01

    Determination of trace Cd in environmental, biological and food samples is of great significance to toxicological research and environmental pollution monitoring. While the direct determination of Cd in real-world samples is difficult due to its low concentration and the complex matrix. Herein, a novel Cd(II)-ion imprinted magnetic mesoporous silica (Cd(II)-II-MMS) was prepared and was employed as a selective magnetic solid-phase extraction (MSPE) material for extraction of trace Cd in real-world samples followed by graphite furnace atomic absorption spectrometry (GFAAS) detection. Under the optimized conditions, the detection limit of the proposed method was 6.1 ng L- 1 for Cd with the relative standard deviation (RSD) of 4.0% (c = 50 ng L- 1, n = 7), and the enrichment factor was 50-fold. To validate the proposed method, Certified Reference Materials of GSBZ 50009-88 environmental water, ZK018-1 lyophilized human urine and NIES10-b rice flour were analyzed and the determined values were in a good agreement with the certified values. The proposed method exhibited a robust anti-interference ability due to the good selectivity of Cd(II)-II-MMS toward Cd(II). It was successfully employed for the determination of trace Cd(II) in environmental water, human urine and rice samples with recoveries of 89.3-116%, demonstrating that the proposed method has good application potential in real world samples with complex matrix.

  9. Green Preconcentration of Trace Amounts of Copper from Water and Food Samples onto Novel Organo-Nanoclay Prior to Flame Atomic Absorption Spectrometry.

    PubMed

    Beyki, Mostafa Hossein; Shemirani, Farzaneh; Khani, Rouhollah

    2014-01-01

    In this work, the nanoclay was intercalated with acyclovir (9-[(2-hydroxyethoxy) methyl] guanine), the toxicity of which to mammalian cells is very low. We used no organic solvents for preparation of modified clay and desorption of Cu ions from the sorbent. Batch and column methods were used, and sorption of Cu was quantitative (>98%) in the pH range of 7.5 to 10.0. Quantitative desorption occurred with 5.0 mL of 3.0 M HCl, and the amount of Cu(II) was measured by using flame atomic absorption spectrometry. In the initial solution the linear dynamic range and the LOD were 3.0-1000.0 and 0.58 μg/L, respectively. With 500.0 mL of sample, an enrichment factor of 100 was obtained. The RSD was 2.0% (n = 8, concentration = 0.5 mg/L), and the maximum capacity of the sorbent was 45.0 mg/g. The influence of experimental parameters including sample pH, ionic strength, type and volume of the eluent, and interference of some ions on the recoveries of Cu was investigated. The proposed method using a new and easier prepared solid sorbent was applied to the determination of Cu in different real samples with satisfactory results.

  10. Evaluation of toxic metals in biological samples (scalp hair, blood and urine) of steel mill workers by electrothermal atomic absorption spectrometry.

    PubMed

    Afridi, Hassan I; Kazi, Tasneem G; Jamali, Mohammad K; Kazi, Gul H; Arain, Mohammad B; Jalbani, Nusrat; Shar, Ghulam Q; Sarfaraz, Raja A

    2006-10-01

    The determination of toxic metals in the biological samples of human beings is an important clinical screening procedure. This study aimed to assess the possible influence of environmental exposure on production workers (PW) and quality control workers (QCW) of a steel mill, all male subjects aged 25-55 years. In this investigation, the concentrations of Pb, Cd, Ni and Cr were determined in biological samples (blood, urine and scalp hair samples) from these steel mill workers in relation to controlled unexposed healthy subjects of the same age group. After pre-treatment with nitric acid-hydrogen peroxide, the samples were digested via a microwave oven, and for comparison purposes, the same samples were digested by the conventional wet acid digestion method. The samples digested were subjected to graphite furnace atomic absorption spectrometry (GFAAS). To assess the reliability of these methods, critical factors, such as detection limit(s), calibration range(s), accuracy and precision, were studied. Quality control for these procedures was established with certified sample of human hair, urine and whole blood. The results indicate that the level of lead, cadmium and nickel in scalp hair, blood and urine samples were significantly higher in both groups of exposed workers (QW and PW) than those of the controls. The possible connection of these elements with the etiology of disease is discussed. The results also show the need for immediate improvements in workplace ventilation and industrial hygiene practices.

  11. Multivariate optimization of cloud point extraction procedure for zinc determination in aqueous extracts of medicinal plants by flame atomic absorption spectrometry.

    PubMed

    Kolachi, N F; Kazi, T G; Khan, S; Wadhwa, S K; Baig, J A; Afridi, H I; Shah, A Q; Shah, F

    2011-10-01

    Cloud point extraction method has been developed for preconcentration of trace quantities of zinc (Zn) in aqueous extract of medicinal plants and blood samples of liver cancer patients using flame atomic absorption spectrometry. The Zn in aqueous extracts of medicinal plants (MPs) was complexed with 2-methyl-8-hydroxyquinoline (quinaldine) and 1-(2-pyridylazo)-2-naphthol (PAN) separately and entrapped in a non-ionic surfactant Triton X-114. After centrifugation, the surfactant-rich phase was diluted with 0.25mL acidic ethyl alcohol. The multivariate strategy was applied to estimate the optimum values of experimental variables (pH, time temperature, ligands and surfactant concentrations). Interactions between analytical factors and their optimal levels were investigated by two level factorial designs. Student's t-test on the results of factorial design with 16 runs for Zn extraction, demonstrated that the factors, ligands concentrations, pH and temperature were statistically significant. The accuracy was assessed by analysis of certified reference materials, namely, BCR 101 (spruce needles), Clincheck control-lyophilized human whole blood. Enhancement factor of 30 and 26 were achieved for the preconcentration of Zn by 2-methyl-8-hydroxyquinoline (L1) and 1-(2-pyridylazo)-2-naphthol (L2), respectively. The relative standard deviation for six replicate determinations of Zn at 10μg/L level using 2-methyl-8-hydroxyquinoline (L1) and 1-(2-pyridylazo)-2-naphthol (L2) were <4% and >5%, respectively.

  12. Determination of bismuth by dielectric barrier discharge atomic absorption spectrometry coupled with hydride generation: method optimization and evaluation of analytical performance.

    PubMed

    Kratzer, Jan; Boušek, Jaroslav; Sturgeon, Ralph E; Mester, Zoltán; Dědina, Jiří

    2014-10-07

    Atomization of bismuth hydride in a 17 W planar quartz dielectric barrier discharge (DBD) atomizer was optimized and the performance of this device compared to that of a conventional quartz tube atomizer (QTA) for atomic absorption spectrometry (AAS). Modification of the inner surface of the DBD atomizer using dimethyldichlorsilane (DMDCS) was essential since it improved sensitivity by a factor of 2-4. Argon, at a flow rate of 125 mL min(-1), was the best DBD discharge gas. Free Bi atoms were also observed in the DBD with nitrogen, hydrogen, and helium discharge gases but not in air. The detection limit for Bi (1.1 ng mL(-1)) is worse than with the QTA (0.16 ng mL(-1) Bi). A poorer detection limit compared to a QTA is a consequence of the shorter optical path of the DBD. Moreover, the lower atomization efficiency and/or faster decay of free atoms in the DBD has to be considered. The performance of the DBD as an atomizer reflects both effects, i.e., atomization efficiency and free atom decay, was estimated to be 65% of that of the externally heated quartz tube atomizer. Nevertheless, this hydride generation DBD-AAS approach can be used for the routine determination of Bi, providing repeatability and accuracy comparable to that reached with a QTA, as demonstrated by analysis of NIST SRM 1643e (trace elements in water). The potential of in-atomizer preconcentration in a DBD atomizer is outlined.

  13. [Speciation analysis of chromium(VI) and chromium(III) in water sample using flame atomic absorption spectrometry with TOA-benzene extraction separation system].

    PubMed

    Shawket, Abliz; Wang, Ji-De; Horshida

    2005-12-01

    A rapid and sensitive method for the sequential determination of Cr(VI) and Cr(III) in water samples based on flame atomic absorption spectrometry with TOA-benzene extraction separation system has been developed. In the H2SO4 medium. Cr(VI) in sample solution was extracted into the organic phase by using the TOA-Benzene and Cr(III) remained in the water phase. Cr(VI) in the organic phase and Cr(III) in the water phase were determined separately by AAS. This method is simple, fast and of microscale. The results obtained by this method agreed well with those obtained by conventional method. The recoveries are 95.0%-102% for Cr(VI) and 94.8-103% for Cr(III). The relative standard deviations were 2.9% for Cr(VI) and 2.6% for Cr(Ill). The system has enrichment effect for Cr(VI), and the detection limits are 6.6 microg x L(-1) for Cr(VI) and 0.20 mg x L(-1) for Cr(III). The maximum extracted amount of Cr(VI) by TOA was 4.6 mg x mL(-1).

  14. Investigation of novel rapidly synergistic cloud point extraction pattern for bismuth in water and geological samples coupling with flame atomic absorption spectrometry determination.

    PubMed

    Wen, Xiaodong; Zhao, Yu; Deng, Qingwen; Ji, Shoulian; Zhao, Xia; Guo, Jie

    2012-04-01

    Rapidly synergistic cloud point extraction (RS-CPE) greatly simplified and accelerated the procedure of traditional cloud point extraction (CPE). In order to expand the application of RS-CPE, this work was carried out after the establishment of the improved extraction technique. The new established extraction method was firstly applied for bismuth extraction and determination coupled with flame atomic absorption spectrometry (FAAS) in this work. The improved RS-CPE was accomplished in the room temperature in 1 min. Non-ionic surfactant Triton X-100 (TX-100) was used as extractant. Octanol worked as cloud point revulsant and synergic reagent. TX-100 has a relatively high cloud point temperature (CPT), which limited its application in CPE. In this work, TX-100 accomplished the RS-CPE procedure in room temperature successfully. The factors influencing RS-CPE, such as concentrations of reagents, pH, conditions of phase separation, effect of environmental temperatures, salt effect and instrumental conditions, were studied systematically. Under the optimal conditions, the limit of detection (LOD) for bismuth was 4.0 μg L(-1), with sensitivity enhancement factor (EF) of 43. The proposed method greatly improved the sensitivity of FAAS for the determination of bismuth and was applied to the determination of trace bismuth in real and certified samples with satisfactory analytical results. The proposed method was rapid, simple, and sensitive.

  15. Imidazole-Modified Nanoporous Silica for Lead Ion Solid Phase Extraction Prior to Determination from Industrial Wastewaters by Flame Atomic Absorption Spectrometry.

    PubMed

    Behbahani, Ali; Ardjmand, Mehdi

    2015-01-01

    A new method was applied to produce modified nanoporous silica as a novel sorbent for Pb(II) ion SPE from industrial wastewater samples. In this modified method, the produced nanoporous silica has a higher functional group loading, which leads to a higher preconcentration factor as well as a lower LOD. This modified nanoporous silica was used for preconcentration prior to subsequent determination of Pb(II) ions by flame atomic absorption spectrometry. Various parameters such as the eluent, pH of the sample solution, and flow rate were optimized during this work. Also, the effect of a variety of ions on preconcentration and recovery of Pb(II) ions was investigated. The LOD, defined as five times the SD of the blank, was determined to be lower than 0.1 mg/L with an RSD of <2%. The accuracy of the method was established by analyzing standard reference materials with certified Pb concentrations. Finally, the established method was successfully applied for determination of the Pb(II) ion concentration in industrial wastewater samples.

  16. Determination of metals in lubricating oils by flame atomic absorption spectrometry using a single-bore high-pressure pneumatic nebulizer.

    PubMed

    Mora, J; Todolí, J L; Sempere, F J; Canals, A; Hernandis, V

    2000-12-01

    The behaviour of a single-bore high-pressure pneumatic nebulizer (SBHPPN) as a tool for the analysis of lubricating oils by flame atomic absorption spectrometry (FAAS) was investigated. The effects of the sample oil content [from 10% to 100% (w/w) oil in 4-methylpentan-2-one, IBMK] and the carrier nature (IBMK and methanol) on the characteristics of the aerosols generated, on the analyte transport efficiency and on the analytical figures of merit in FAAS were studied. A pneumatic concentric nebulizer (PCN) was used for comparison. Increasing the oil content increases the viscosity of the sample. With the PCN this gives rise to coarser aerosols, making it impossible to nebulize samples with an oil content higher than 70% (w/w). Using the SBHPPN, the viscosity of the sample scarcely affects the characteristics of the primary aerosols. Hence, the SBHPPN is able, by using the appropriate carrier, to nebulize pure lubricating oils. Among the carriers tested, IBMK is the most advisable because it is fully miscible with all the oil samples. The SBHPPN provides higher sensitivities and lower limits of detection than the PCN. Compared with a method based on organic dilution, the use of the SBHPPN for the direct analysis of lubricating oils by FAAS makes it possible, in addition to increasing the analysis throughput, to detect elements at lower concentrations. Moreover, the SBHPPN provides similar results to those obtained using a previous acid digestion step.

  17. High current–density anodic electrodissolution in flow–injection systems for the determination of aluminium, copper and zinc in non–ferroalloys by flame atomic absorption spectrometry

    PubMed Central

    Giacomozzi, César Augusto; de Queiróz, Roldão R. U.; Souza, Ivan Gonçalves

    1999-01-01

    An automatic procedure with a high current-density anodic electrodissolution unit (HDAE) is proposed for the determination of aluminium, copper and zinc in non-ferroalloys by flame atomic absorption spectrometry, based on the direct solid analysis. It consists of solenoid valve-based commutation in a flow-injection system for on-line sample electro-dissolution and calibration with one multi-element standard, an electrolytic cell equipped with two electrodes (a silver needle acts as cathode, and sample as anode), and an intelligent unit. The latter is assembled in a PC-compatible microcomputer for instrument control, and for data acquisition and processing. General management of the process is achieved by use of software written in Pascal. Electrolyte compositions, flow rates, commutation times, applied current and electrolysis time were investigated. A 0.5 mol l-1 HN03 solution was elected as electrolyte and 300 A/cm2 as the continuous current pulse. The performance of the proposed system was evaluated by analysing aluminium in Al-alloy samples, and copper/zinc in brass and bronze samples, respectively. The system handles about 50 samples per hour. Results are precise (R.S.D. < 2%) and in agreement with those obtained by ICP-AES and spectrophotometry at a 95% confidence level. PMID:18924839

  18. On-line preconcentration/determination of zinc from water, biological and food samples using synthesized chelating resin and flame atomic absorption spectrometry.

    PubMed

    Yılmaz, Sibel; Tokalıoğlu, Serife; Sahan, Serkan; Ulgen, Ahmet; Sahan, Ahmet; Soykan, Cengiz

    2013-04-01

    An on-line flow injection pre-concentration-flame atomic absorption spectrometry method was developed to determine trace zinc in water (tap, dam, and well water), biological (hair and nail), and liver samples. As a solid phase extractant, a synthesized new chelating resin, poly(2-thiozylmethacrylamide-co-divinylbenzene-co-2-acrylamido-2-methyl-1-propane sulfonic acid) was used. The resin was characterized by Fourier transform infrared spectroscopy, elemental analysis, and surface area by nitrogen sorption. A pre-concentration factor of 40-fold for a sample volume of 12.6 mL was obtained by using the time-based technique. The detection limit for the pre-concentration method was found to be 2.2 μg L(-1). The precision (as RSD,%) for 10 replicate determinations at the 0.04 μg mL(-1) Zn concentration was 1.2%. The calibration graph using the pre-concentration system for zinc was linear with a correlation coefficient of 0.998 in the concentration range from 0.005 to 0.05 μg mL(-1). The applicability and accuracy of the developed method were estimated by the analysis spiked water, biological, liver samples (83-105%), and also certified reference material TMDA-70 (fortified lake water) and SPS-WW1 Batch 111-Wastewater. The results were in agreement with the certified values.

  19. Multivariate approach in the optimization procedures for the direct determination of manganese in serum samples by graphite furnace atomic absorption spectrometry.

    PubMed

    Fabrino, Henrique José Ferraz; Silveira, Josianne Nicácio; Neto, Waldomiro Borges; Goes, Alfredo Miranda; Beinner, Mark Anthony; da Silva, José Bento Borba

    2011-10-01

    A method for direct determination of manganese (Mn) in human serum by graphite furnace atomic absorption spectrometry (GFAAS) was proposed in this work. The samples were only diluted 1:4 with nitric acid 1% (v/v) and Triton(®) X-100 0.1% (v/v). The optimization of the instrumental conditions was made using multivariate approach. A factorial design (2(3)) was employed to investigate the tendency of the most intense absorbance signal. The pyrolysis and atomization temperatures and the use of modifier were available and only the parameter modifier use did not have a significant effect on the response. A Center Composed Design (CCD) presented best temperatures of 430 °C and 2568 °C for pyrolysis and atomization, respectively. The method allowed the determination of manganese with a curve varying from 0.7 to 3.3 μg/L. Recovery studies in three concentration levels (n=7 for each level) presented results from 98 ± 5 to 102 ± 7 %. The detection limit was 0.2 μg/L, the quantifying limit was 0.7 μg/L, and the characteristic mass, 1.3 ± 0.2 pg. Intra- and interassay studies showed coefficients of variation of 4.7-7.0% (n=21) and 6-8%(n=63), respectively. The method was applied for the determination of manganese in 53 samples obtaining concentrations from 3.9 to 13.7 μg/L.

  20. Ligandless dispersive liquid--liquid microextraction of iron in biological and foodstuff samples and its determination by Electrothermal atomic absorption spectrometry.

    PubMed

    Madadizadeh, Mohadeseh; Taher, Mohammad Ali; Ashkenani, Hamid

    2013-01-01

    A new, simple, and efficient method comprising ligandless dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry is reported for the preconcentration and determination of ultratrace amounts of Fe(III). Carbon tetrachloride and acetone were used as the extraction and disperser solvents, respectively. Some effective parameters of the microextraction such as choice of extraction and disperser solvents, their volume, extraction time and temperature, salt and surfactant effect, and pH were optimized. Under the optimum conditions, the calibration curve was linear in the range of 0.02 to 0.46 microg/L of Fe(III), with LOD and LOQ of 5.2 and 17.4 ng/L, respectively. The RSD for seven replicated determinations of Fe(IIl) ion at 0.1 microg/L concentration level was 5.2%. Operational simplicity, rapidity, low cost, good repeatability, and low consumption of extraction solvent are the main advantages of the proposed method. The method was successfully applied to the determination of iron in biological, food, and certified reference samples.

  1. Speciation of antimony(III) and antimony(V) by electrothermal atomic absorption spectrometry after ultrasound-assisted emulsification of solidified floating organic drop microextraction.

    PubMed

    Wen, Shengping; Zhu, Xiashi

    2013-10-15

    A simple, sensitive and efficient method of ultrasound-assisted emulsification of solidified floating organic drop microextraction (USE-SFODME) coupled to electrothermal atomic absorption spectrometry for the speciation of antimony at different oxidation state Sb(III)/Sb(V) in environmental samples was established. In this method, the hydrophobic complex of Sb(III) with sodium diethyldithiocarbamate (DDTC) is extracted by 1-undecanol at pH 9.0, while Sb(V) remains in aqueous phase. Sb(V) content can be calculated by subtracting Sb(III) from the total antimony after reducing Sb(V) to Sb(III) by l-cysteine. Various factors affecting USE-SFODME including pH, extraction solvent and its volume, concentration of DDTC, sonication time, and extraction temperature were investigated. Under the optimized conditions, the calibration curve was linear in the range from 0.05 to 10.0 ng mL(-1), with the limit of detection (3σ) 9.89 ng L(-1) for Sb(III). The relative standard deviation for Sb(III) was 4.5% (n=9, c=1.0 ng mL(-1)). This method was validated against the certified reference materials (GSB 07-1376-2001, GBW07441), and applied to the speciation of antimony in environmental samples (soil and water samples) with satisfactory results.

  2. Optimization of a hydride generation metallic furnace atomic absorption spectrometry (HG-MF-AAS) method for tin determination: analytical and morphological parameters of a metallic atomizer.

    PubMed

    Moretto Galazzi, Rodrigo; Arruda, Marco Aurélio Zezzi

    2013-12-15

    The present work describes a metallic tube as hydride atomizer for atomic absorption spectrometry. Its performance is evaluated through tin determination, and the accuracy of the method assessed through the analysis of sediment and water samples. Some chemical parameters (referring to the generation of the hydride) such as acid, NaOH and THB concentrations, as well as physical parameters (referring to the transport of the hydride) such as carrier, acetylene, air flow-rates, flame composition, coil length, tube hole area, among others, are evaluated for optimization of the method. Scanning electron microscopy is used for evaluating morphological parameters in both new and used (after 150 h) tube atomizers. The method presents linear Sn concentration from 50 to 1000 µg L(-1) (r>0.9995; n=3) and the analytical frequency of ca. 40 h(-1). The limit of detection (LOD) is 7.1 µg L(-1) and the precision, expressed as RSD is less than 4% (200 µg L(-1); n=10). The accuracy is evaluated through reference materials, and the results are similar at 95% confidence level according to the t-test.

  3. Investigation of chemical modifiers for sulfur determination in diesel fuel samples by high-resolution continuum source graphite furnace molecular absorption spectrometry using direct analysis

    NASA Astrophysics Data System (ADS)

    Huber, Charles S.; Vale, Maria Goreti R.; Welz, Bernhard; Andrade, Jailson B.; Dessuy, Morgana B.

    2015-06-01

    High-resolution continuum source graphite furnace molecular absorption spectrometry has been applied for sulfur determination in diesel fuel. The sharp rotational lines of the carbon monosulfide molecule (formed during the vaporization step) were used to measure the absorbance. The analytical line at 258.056 nm was monitored using the sum of three pixels. Different chemical modifiers were investigated and the mixture of palladium and magnesium was used as chemical modifier in combination with iridium as permanent modifier. L-Cysteine was chosen as sulfur standard and the calibration was done against aqueous standard solutions. The proposed method was applied for the analyses of four diesel samples: two S10 samples and two S500 samples. The trueness of the method was checked with a certified reference material (CRM) of sulfur in diesel fuel (NIST 2724b). Accurate results, for samples and CRM, were achieved after a dilution with propan-1-ol. The following figures of merit were obtained: characteristic mass of 17 ± 3 ng, limit of detection and limit of quantification of 1.4 mg kg- 1 and 4.7 mg kg- 1, respectively.

  4. Hollow fiber liquid phase microextraction combined with graphite furnace atomic absorption spectrometry for the determination of methylmercury in human hair and sludge samples

    NASA Astrophysics Data System (ADS)

    Jiang, Hongmei; Hu, Bin; Chen, Beibei; Zu, Wanqing

    2008-07-01

    Two methods, based on hollow fiber liquid-liquid-liquid (three phase) microextraction (HF-LLLME) and hollow fiber liquid phase (two phase) microextraction (HF-LPME), have been developed and critically compared for the determination of methylmercury content in human hair and sludge by graphite furnace atomic absorption spectrometry (GFAAS). In HF-LPME, methylmercury was extracted into the organic phase (toluene) prior to its determination by GFAAS, while inorganic mercury remained as a free species in the sample solution. In HF-LLLME, methylmercury was first extracted into the organic phase (toluene) and then into the acceptor phase (4% thiourea in 1 mol L - 1 HCl) prior to its determination by GFAAS, while inorganic mercury remained in the sample solution. The total mercury was determined by inductively coupled plasma-mass spectrometry (ICP-MS), and the levels of inorganic mercury in both HF-LLLME and HF-LPME were obtained by subtracting methylmercury from total mercury. The factors affecting the microextraction of methylmercury, including organic solvent, extraction time, stirring rate and ionic strength, were investigated and the optimal extraction conditions were established for both HF-LLLPME and HF-LPME. With a consumption of 3.0 mL of the sample solution, the enrichment factors were 204 and 55 for HF-LLLPME and HF-LPME, respectively. The limits of detection (LODs) for methylmercury were 0.1 μg L - 1 and 0.4 μg L - 1 (as Hg) with precisions (RSDs (%), c = 5 μg L - 1 (as Hg), n = 5) of 13% and 11% for HF-LLLPME-GFAAS and HF-LPME-GFAAS, respectively. For ICP-MS determination of total mercury, a limit of detection of 39 ng L - 1 was obtained. Finally, HF-LLLME-GFAAS was applied to the determination of methylmercury content in human hair and sludge, and the recoveries for the spiked samples were in the range of 99-113%. In order to validate the method, HF-LLLME-GFAAS was also applied to the analysis of a certified reference material of NRCC DORM-2 dogfish

  5. Simultaneous determination of cadmium, iron and tin in canned foods using high-resolution continuum source graphite furnace atomic absorption spectrometry.

    PubMed

    Leao, Danilo J; Junior, Mario M S; Brandao, Geovani C; Ferreira, Sergio L C

    2016-06-01

    A method was established to simultaneously determine cadmium, iron and tin in canned-food samples using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS). The quantification step has been performed using the primary line (228.802nm) for cadmium and the adjacent secondary lines (228.725nm and 228.668nm) for iron and tin, respectively. The selected chemical modifier was an acid solution that contained a mixture of 0.1% (w/v) Pd and 0.05% (w/v) Mg. The absorbance signals were measured based on the peak area using 3 pixels for cadmium and 5 pixels for iron and tin. Under these conditions, cadmium, iron and tin have been determined in canned-food samples using the external calibration technique based on aqueous standards, where the limits of quantification were 2.10ngg(-1) for cadmium, 1.95mgkg(-1) for iron and 3.00mgkg(-1) for tin, and the characteristic masses were 1.0pg for cadmium, 0.9ng for iron and 1.1ng for tin. The precision was evaluated using two solutions of each metal ion, and the results, which were expressed as the relative standard deviation (RSD%), were 3.4-6.8%. The method accuracy for cadmium and iron was confirmed by analyzing a certified reference material of apple leaves (NIST 1515), which was supplied by NIST. However, for tin, the accuracy was confirmed by comparing the results of the proposed method and another analytical technique (inductively coupled plasma optical emission spectrometry). The proposed procedure was applied to determine cadmium, iron and tin in canned samples of peeled tomato and sardine. Eleven samples were analyzed, and the analyte concentrations were 3.57-62.9ngg(-1), 2.68-31.48mgkg(-1) and 4.06-122.0mgkg(-1) for cadmium, iron and tin, respectively. In all analyzed samples, the cadmium and tin contents were lower than the permissible maximum levels for these metals in canned foods in the Brazilian legislation.

  6. Fast heating induced impulse halogenation of refractory sample components in electrothermal atomic absorption spectrometry by direct injection of a liquid halogenating agent.

    PubMed

    György, Krisztina; Ajtony, Zsolt; Van Meel, Katleen; Van Grieken, René; Czitrovszky, Aladár; Bencs, László

    2011-09-15

    A novel electrothermal atomic absorption spectrometry (ETAAS) method was developed for the halogenation of refractory sample components (Er, Nd and Nb) of lithium niobate (LiNbO(3)) and bismuth tellurite (Bi(2)TeO(5)) optical single crystals to overcome memory effects and carry-over. For this purpose, the cleaning step of a regular graphite furnace heating program was replaced with a halogenation cycle. In this cycle, after the graphite tube cooled to room temperature, a 20 μL aliquot of liquid carbon tetrachloride (CCl(4)) was dispensed with a conventional autosampler into the graphite tube. The CCl(4) was partially dried at 80°C under the mini-flow (40 cm(3) min(-1)) condition of the Ar internal furnace gas (IFG), then the residue was decomposed (pyrolyzed) by fast furnace heating at 1900-2100°C under interrupted flow of the IFG. This step was followed by a clean-out stage at 2100°C under the maximum flow of the IFG. The advantage of the present method is that it does not require any alteration to the graphite furnace gas supply system in contrast to most of the formerly introduced halogenation techniques. The effectiveness of the halogenation method was verified with the determination of Er and Nd dopants in the optical crystals. In these analyses, a sensitivity decrease was observed, which was likely due to the enhanced deterioration of the graphite tube surface. Therefore, the application of mathematical correction (resloping) of the calibration was also required. The calibration curves were linear up to 1.5 and 10 μmol L(-1) for Er and Nd, respectively. Characteristic masses of 18 and 241 pg and the limit of detection (LOD) values of 0.017 and 0.27 μmol L(-1) were found for Er and Nd, respectively. These LOD data correspond to 0.68 μmol mol(-1) Er and 11 μmol mol(-1) Nd in solid bismuth tellurite samples. The analytical results were compared with those obtained by a conventional ETAAS method and validated with X-ray fluorescence spectrometry analysis.

  7. Determination of Cd, Co, Cu, Mn, Ni, Pb, and Zn by Inductively Coupled Plasma Mass Spectroscopy or Flame Atomic Absorption Spectrometry after On-line Preconcentration and Solvent Extraction by Flow Injection System

    PubMed

    Bortoli; Gerotto; Marchiori; Mariconti; Palonta; Troncon

    1996-11-01

    The concentrations of Cd, Co, Cu, Mn, Ni, Pb, and Zn in natural and sea waters are too low to be directly determined with by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GFAAS). Specific sample preparations are requested that make possible the determination of these analytes by preconcentration or extraction. These techniques are affected by severe problems of sample contamination. In this work Cd, Co, Cu, Mn, Ni, Pb, and Zn were determined by inductively coupled plasma mass spectroscopy (ICP-MS) or by atomic absorption spectrometry, in fresh and seawater samples, after on-line preconcentration and following solvent elution with a flow injection system. Bonded silica with octadecyl functional group C18, packed in a microcolumn of 100-μl capacity, was used to collect diethyldithiocarbamate complexes of the heavy metals in aqueous solutions. The metals are complexed with a chelating agent, adsorbed on the C18 column, and eluted with methanol directly in the flow injection system. The methanolic stream can be addressed to FAAS for direct determination of Cu, Ni, and Zn, or collected in a vial for successive analysis by GFAAS. The eluted samples can be also dried in a vacuum container and restored to a little volume with concentrated HNO3 and Milli-Q water for analysis by ICP-MS or GFAAS.

  8. Fast determination of trace elements in organic fertilizers using a cup-horn reactor for ultrasound-assisted extraction and fast sequential flame atomic absorption spectrometry.

    PubMed

    Teixeira, Leonel Silva; Vieira, Heulla Pereira; Windmöller, Cláudia Carvalhinho; Nascentes, Clésia Cristina

    2014-02-01

    A fast and accurate method based on ultrasound-assisted extraction in a cup-horn sonoreactor was developed to determine the total content of Cd, Co, Cr, Cu, Mn, Ni, Pb and Zn in organic fertilizers by fast sequential flame atomic absorption spectrometry (FS FAAS). Multivariate optimization was used to establish the optimal conditions for the extraction procedure. An aliquot containing approximately 120 mg of the sample was added to a 500 µL volume of an acid mixture (HNO3/HCl/HF, 5:3:3, v/v/v). After a few minutes, 500 µL of deionized water was added and eight samples were simultaneously sonicated for 10 min at 50% amplitude, allowing a sample throughput of 32 extractions per hour. The performance of the method was evaluated with a certified reference material of sewage sludge (CRM 029). The precision, expressed as the relative standard deviation, ranged from 0.58% to 5.6%. The recoveries of analytes were found to 100%, 109%, 96%, 92%, 101%, 104% and 102% for Cd, Cr, Cu, Mn, Ni, Pb and Zn, respectively. The linearity, limit of detection and limit of quantification were calculated and the values obtained were adequate for the quality control of organic fertilizers. The method was applied to the analysis of several commercial organic fertilizers and organic wastes used as fertilizers, and the results were compared with those obtained using the microwave digestion procedure. A good agreement was found between the results obtained by microwave and ultrasound procedures with recoveries ranging from 80.4% to 117%. Two organic waste samples were not in accordance with the Brazilian legislation regarding the acceptable levels of contaminants.

  9. Determination of cadmium and lead in urine samples after dispersive solid-liquid extraction on multiwalled carbon nanotubes by slurry sampling electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Álvarez Méndez, J.; Barciela García, J.; García Martín, S.; Peña Crecente, R. M.; Herrero Latorre, C.

    2015-04-01

    A new method for the determination of Cd and Pb in urine samples has been developed. The method involves dispersive solid-phase extraction (DSPE), slurry sampling (SS), and subsequent electrothermal atomic absorption spectrometry (ETAAS). Oxidized multiwalled carbon nanotubes (MWCNTs) were used as the sorbent material. The isolated MWCNT/analyte aggregates were treated with nitric acid to form a slurry and both metals were determined directly by injecting the slurry into the ETAAS-atomizer. The parameters that influence the adsorption of the metals on MWCNTs in the DSPE process, the formation and extraction of the slurry, and the ETAAS conditions were studied by different factorial design strategies. The detection and quantification limits obtained for Cd under optimized conditions were 9.7 and 32.3 ng L- 1, respectively, and for Pb these limits were 0.13 and 0.43 μg L- 1. The preconcentration factors achieved were 3.9 and 5.4. The RSD values (n = 10) were less than 4.1% and 5.9% for Cd and Pb, respectively. The accuracy of the method was assessed in recovery studies, with values in the range 96-102% obtained for Cd and 97-101% for Pb. In addition, the analysis of certified reference materials gave consistent results. The DSPE-SS-ETAAS method is a novel and useful strategy for the determination of Pb and Cd at low levels in human urine samples. The method is sensitive, fast, and free of matrix interferences, and it avoids the tedious and time-consuming on-column adsorption and elution steps associated with commonly used SPE procedures. The proposed method was used to determine Cd and Pb in urine samples of unexposed healthy people and satisfactory results were obtained.

  10. Development of an analytical method for the determination of arsenic in gasoline samples by hydride generation-graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Becker, Emilene M.; Dessuy, Morgana B.; Boschetti, Wiliam; Vale, Maria Goreti R.; Ferreira, Sérgio L. C.; Welz, Bernhard

    2012-05-01

    The purpose of the present work was to optimize the conditions for the determination of arsenic in gasoline with hydride generation-graphite furnace atomic absorption spectrometry after acid digestion using a full two-level factorial design with center point. The arsine was generated in a batch system and collected in a graphite tube coated with 150 μg Ir as a permanent modifier. The sample volume, the pre-reduction conditions, the temperature program and modifier mass were kept fixed for all experiments. The estimated main effects were: reducing agent concentration (negative effect), acid concentration (negative effect) and trapping temperature (positive effect). It was observed that there were interactions between the variables. Moreover, the curvature was significant, indicating that the best conditions were at the center point. The optimized parameters for arsine generation were 2.7 mol L- 1 hydrochloric acid and 1.6% (w/v) sodium tetrahydroborate. The optimized conditions to collect arsine in the graphite furnace were a trapping temperature of 250 °C and a collection time of 30 s. The limit of detection was 6.4 ng L- 1 and the characteristic mass was 24 pg. Two different systems for acid digestion were used: a digester block with cold finger and a microwave oven. The concentration of arsenic found with the proposed method was compared with that obtained using a detergentless microemulsion and direct graphite furnace determination. The results showed that the factorial design is a simple tool that allowed establishing the appropriate conditions for sample preparation and also helped in evaluating the interaction between the factors investigated.

  11. Activated carbon-modified knotted reactor coupled to electrothermal atomic absorption spectrometry for sensitive determination of arsenic species in medicinal herbs and tea infusions

    NASA Astrophysics Data System (ADS)

    Grijalba, Alexander Castro; Martinis, Estefanía M.; Lascalea, Gustavo E.; Wuilloud, Rodolfo G.

    2015-01-01

    A flow injection system based on a modified polytetrafluoroethylene (PTFE) knotted reactor (KR) was developed for arsenite [As(III)] and arsenate [As(V)] species preconcentration and determination by electrothermal atomic absorption spectrometry (ETAAS). Activated carbon (AC) was immobilized on the inner walls of a PTFE KR by a thermal treatment. A significant increase in analyte retention was obtained with the AC-modified KR (100%) as compared to the regular PTFE KR (25%). The preconcentration method involved the on-line formation of As(III)-ammonium pyrrolidinedithiocarbamate (As-APDC) complex, followed by its adsorption onto the inner walls of the AC-modified KR. After analyte retention, the complex was eluted with acetone directly into the graphite furnace of ETAAS. The parameters affecting the flow injection system were evaluated with a full central composite face centered design with three center points. Under optimum conditions, a preconcentration factor of 200 was obtained with 10 ml of sample. The detection limit was 4 ng L- 1 and the relative standard deviation (RSD) for six replicate measurements at 0.2 μg L- 1 of As were 4.3% and 4.7% for As(III) and As(V), respectively. The developed methodology was highly selective towards As(III), while As(V), monomethylarsonic acid [MMA(V)] and dimethylarsinic [DMA(V)] were not retained in the AC-modified KR. The proposed method was successfully applied for As speciation analysis in infusions originated from medicinal herbs and tea.

  12. A novel analytical system involving hydride generation and gold-coated W-coil trapping atomic absorption spectrometry for selenium determination at ng l - 1 level

    NASA Astrophysics Data System (ADS)

    Kula, İ.; Arslan, Y.; Bakırdere, S.; Ataman, O. Y.

    2008-08-01

    A novel analytical technique was developed where gaseous hydrogen selenide formed by sodium tetrahydroborate reduction is transported to and trapped on a resistively heated gold-coated W-coil atom trap for in situ preconcentration. Gold coating on W-coil was prepared by using an organic solution of Au. The atom trap is held at 165 °C during the collection stage and is heated up to 675 °C for revolatilization; analyte species formed are transported to an externally heated quartz T-tube where the atomization takes place and the transient signal is obtained. The carrier gas consisted of 112.5 ml min - 1 Ar with 75 ml min - 1 H 2 during the collection step and 112.5 ml min - 1 Ar with 450 ml min - 1 H 2 in the revolatilization step. The half width of the transient signal obtained is less than 0.5 s. The RSD for the measurements was found to be 3.9% ( n = 11) for 0.10 µg l - 1 Se using peak height measurements. The calibration plot for 27.0 ml of sample collected in 4.0 min using a flow rate of 6.75 ml min - 1 was linear between 0.13 and 2.0 µg l - 1 of Se. The limit of detection (3 s) is 39 ng l - 1 . The enhancement factor for the characteristic concentration ( Co) was found to be 20.1 when compared to conventional hydride generation atomic absorption spectrometry system without trap. In order to check the accuracy of the method, standard reference material, natural water NIST 1640 was employed; the result was found to be in good agreement with the certified value at the 95% confidence level.

  13. Investigation of chemical modifiers for the determination of lead in fertilizers and limestone using graphite furnace atomic absorption spectrometry with Zeeman-effect background correction and slurry sampling

    NASA Astrophysics Data System (ADS)

    Borges, Aline R.; Becker, Emilene M.; Dessuy, Morgana B.; Vale, Maria Goreti R.; Welz, Bernhard

    2014-02-01

    In this work, chemical modifiers in solution (Pd/Mg, NH4H2PO4 and NH4NO3/Pd) were compared with permanent modifiers (Ir and Ru) for the determination of lead in fertilizer and limestone samples using slurry sampling and graphite furnace atomic absorption spectrometry with Zeeman-effect background correction. The analytical line at 283.3 nm was used due to some spectral interference observed at 217.0 nm. The NH4H2PO4 was abandoned due to severe spectral interference even at the 283.3-nm line. For Pd/Mg and NH4NO3/Pd the optimum pyrolysis and atomization temperatures were 900 °C and 1900 °C, respectively. For Ru and Ir, the integrated absorbance signal was stable up to pyrolysis temperatures of 700 °C and 900 °C, respectively, and up to atomization temperature of 1700 °C. The limit of detection (LOD) was 17 ng g- 1 using Pd/Mg and 29 ng g- 1 using NH4NO3/Pd. Among the permanent modifiers investigated, the LOD was 22 ng g- 1 Pb for Ir and 10 ng g- 1 Pb for Ru. The accuracy of the method was evaluated using the certified reference material NIST SRM 695. Although Ru provided lower LOD, which can be attributed to a lower blank signal, only the modifiers in solution showed concordant values of Pb concentration for the NIST SRM 695 and the most of analyzed samples. Moreover, the Pd/Mg modifier provided the highest sensitivity and for this reason it is more suitable for the determination of Pb in fertilizers samples in slurry; besides this it presented a better signal-to-noise ratio than NH4NO3/Pd.

  14. Suspended nanoparticles in surfactant media as a microextraction technique for simultaneous separation and preconcentration of cobalt, nickel and copper ions for electrothermal atomic absorption spectrometry determination.

    PubMed

    Dadfarnia, Shayessteh; Shakerian, Farid; Shabani, Ali Mohammad Haji

    2013-03-15

    The aim of this study was to describe a new method of microextraction based on the suspension of alumina nanoparticles in the surfactant media for simultaneous separation and preconcentration of the ultra-traces of cobalt, nickel and copper ions. In this technique, the alumina nanoparticles were suspended in the non-ionic surfactant solution of Triton X-114. The analytes in the sample solution were adsorbed onto the nanoparticles. After the phase separation based on the cloud point of the mixture at 40 °C, the nanoparticles settled down in the surfactant rich phase. Then 120 μL of nitric acid (3.0 mol L(-1)) was added to the surfactant rich phase which caused desorption of the analytes. Finally, the liquid phase was separated by centrifugation from the nanoparticles and was used for the quantification of the analytes by the electrothermal atomic absorption spectrometry (ETAAS). The parameters affecting the extraction and detection processes were optimized. Under the optimized experimental conditions (i.e. pH∼8, Triton X-114, 0.05% (v/v); temperature 40 °C), a sample volume of 25 mL resulted in the enhancement factors of 198, 205 and 206 and detection limits (defined as 3Sb/m) of 2.5, 2.8 and 2.6 ng L(-1) for Co(II), Ni(II) and Cu(II) respectively. The sorbent showed high capacity for these metal ions (30-40 mg g(-1) sorbent). The method was successfully applied to the determination of the analytes in natural water samples.

  15. Multiple response optimization for Cu, Fe and Pb determination in naphtha by graphite furnace atomic absorption spectrometry with sample injection as detergent emulsion

    NASA Astrophysics Data System (ADS)

    Brum, Daniel M.; Lima, Claudio F.; Robaina, Nicolle F.; Fonseca, Teresa Cristina O.; Cassella, Ricardo J.

    2011-05-01

    The present paper reports the optimization for Cu, Fe and Pb determination in naphtha by graphite furnace atomic absorption spectrometry (GF AAS) employing a strategy based on the injection of the samples as detergent emulsions. The method was optimized in relation to the experimental conditions for the emulsion formation and taking into account that the three analytes (Cu, Fe and Pb) should be measured in the same emulsion. The optimization was performed in a multivariate way by employing a three-variable Doehlert design and a multiple response strategy. For this purpose, the individual responses of the three analytes were combined, yielding a global response that was employed as a dependent variable. The three factors related to the optimization process were: the concentration of HNO 3, the concentration of the emulsifier agent (Triton X-100 or Triton X-114) in aqueous solution used to emulsify the sample and the volume of solution. At optimum conditions, it was possible to obtain satisfactory results with an emulsion formed by mixing 4 mL of the samples with 1 mL of a 4.7% w/v Triton X-100 solution prepared in 10% v/v HNO 3 medium. The resulting emulsion was stable for 250 min, at least, and provided enough sensitivity to determine the three analytes in the five samples tested. A recovery test was performed to evaluate the accuracy of the optimized procedure and recovery rates, in the range of 88-105%; 94-118% and 95-120%, were verified for Cu, Fe and Pb, respectively.

  16. Speciation and determination of ultra trace amounts of inorganic tellurium in environmental water samples by dispersive liquid-liquid microextraction and electrothermal atomic absorption spectrometry.

    PubMed

    Najafi, Nahid Mashkouri; Tavakoli, Hamed; Alizadeh, Reza; Seidi, Shahram

    2010-06-18

    A simple and powerful method has been developed for the rapid and selective determination of Te(IV) and Te(VI), employing dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry using palladium as permanent modifier. Under acidic conditions pH 1, only Te(IV) can form a complex with ammonium pyrrolidine dithiocarbamate (APDC) and therefore be extracted into fine droplets of carbon tetrachloride (extraction solvent) which are dispersed with ethanol into the water sample solution. After centrifugation, Te(IV) was determined in the sedimented organic phase while Te(VI) remained in the aqueous phase. Total inorganic tellurium was determined after the reduction of the Te(VI) to Te(IV). Te(VI) was calculated as the difference between the measured total inorganic tellurium and Te(IV) content. The effective parameters for improving the efficiency of microextraction process were investigated by using experimental and central composite designs. Under optimal conditions the enrichment factor was 125 and the calibration graph was linear in the range of 0.015-1 ng mL(-1) with detection limit and characteristic mass of 0.004 ng mL(-1) and 0.033 pg, respectively. The relative standard deviation for 0.5 ng mL(-1) of tellurium measurement was 3.6% (n=6) at ash and atomization temperature, 900 and 2600 degrees C, respectively. The recoveries of spiked Te(IV) and Te(VI) to the environmental water samples were 89.6-101.3% and 96.6-99.1%, respectively. The accuracy is also evaluated by applying the proposed method to certified reference material (NIST SRM 1643e), for which the result was in a good agreement with the certified values reported for this CRM (95% confidence level).

  17. Direct determination of chromium in infant formulas employing high-resolution continuum source electrothermal atomic absorption spectrometry and solid sample analysis.

    PubMed

    Silva, Arlene S; Brandao, Geovani C; Matos, Geraldo D; Ferreira, Sergio L C

    2015-11-01

    The present work proposed an analytical method for the direct determination of chromium in infant formulas employing the high-resolution continuum source electrothermal atomic absorption spectrometry combined with the solid sample analysis (SS-HR-CS ET AAS). Sample masses up to 2.0mg were directly weighted on a solid sampling platform and introduced into the graphite tube. In order to minimize the formation of carbonaceous residues and to improve the contact of the modifier solution with the solid sample, a volume of 10 µL of a solution containing 6% (v/v) H2O2, 20% (v/v) ethanol and 1% (v/v) HNO3 was added. The pyrolysis and atomization temperatures established were 1600 and 2400 °C, respectively, using magnesium as chemical modifier. The calibration technique was evaluated by comparing the slopes of calibration curves established using aqueous and solid standards. This test revealed that chromium can be determined employing the external calibration technique using aqueous standards. Under these conditions, the method developed allows the direct determination of chromium with limit of quantification of 11.5 ng g(-1), precision expressed as relative standard deviation (RSD) in the range of 4.0-17.9% (n=3) and a characteristic mass of 1.2 pg of chromium. The accuracy was confirmed by analysis of a certified reference material of tomato leaves furnished by National Institute of Standards and Technology. The method proposed was applied for the determination of chromium in five different infant formula samples. The chromium content found varied in the range of 33.9-58.1 ng g(-1) (n=3). These samples were also analyzed employing ICP-MS. A statistical test demonstrated that there is no significant difference between the results found by two methods. The chromium concentrations achieved are lower than the maximum limit permissible for chromium in foods by Brazilian Legislation.

  18. A new supramolecular based liquid solid microextraction method for preconcentration and determination of trace bismuth in human blood serum and hair samples by electrothermal atomic absorption spectrometry.

    PubMed

    Kahe, Hadi; Chamsaz, Mahmoud

    2016-11-01

    A simple and reliable supramolecule-aggregated liquid solid microextraction method is described for preconcentration and determination of trace amounts of bismuth in water as well as human blood serum and hair samples. Catanionic microstructures of cetyltrimethylammonium bromide (CTAB) and sodium dodecyl sulfate (SDS) surfactants, dissolved in deionized water/propanol, are used as a green solvent to extract bismuth (III)-diethyldithiocarbamate complexes by dispersive microextraction methodology. The extracted solid phase is easily removed and dissolved in 50 μL propanol for subsequent measurement by electrothermal atomic absorption spectrometry (ET-AAS). The procedure benefits the merits of supramolecule aggregates' properties and dispersive microextraction technique using water as the main component of disperser solvent, leading to direct interaction with analyte. Phase separation behavior of extraction solvent and different parameters influencing the extraction efficiency of bismuth ion such as salt concentration, pH, centrifugation time, amount of chelating agent, SDS:CTAB mole ratio, and solvent amounts were thoroughly optimized. Under the optimal experimental conditions, the calibration curve was linear in the range of 0.3-6 μg L(-1) Bi (III) with a limit of detection (LOD) of 0.16 μg L(-1) (S/N = 3). The relative standard deviations (RSD) of determination were obtained to be 5.1 and 6.2 % for 1 and 3 μg L(-1) of Bi (III), respectively. The developed method was successfully applied as a sensitive and accurate technique for determination of bismuth ion in human blood serum, hair samples, and a certified reference material.

  19. Development of new portable miniaturize solid phase microextraction of silver-APDC complex using micropipette tip in-syringe system couple with electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Naeemullah; Kazi, Tasneem Gul; Afridi, Hassan Imran; Shah, Faheem; Arain, Sadaf Sadia; Arain, Salma Aslam; Panhwar, Abdul Haleem; Arain, Mariam Shahzadi; Samoon, Muhammad Kashif

    2016-02-01

    An innovative and simple miniaturized solid phase microextraction (M-SPME) method, was developed for preconcentration and determination of silver(I) in the fresh and waste water samples. For M-SPME, a micropipette tip packed with activated carbon cloth (ACC) as sorbent, in a syringe system. The size, morphology and elemental composition of ACC before and after adsorption of analyte have been characterized by scanning electron microscopy and energy dispersive spectroscopy. The sample solution treated with a complexing reagent, ammonium pyrrolidine dithiocarbamate (APDC), was drawn into the syringe filled with ACC and dispensed manually for 2 to 10 aspirating/dispensing cycle. Then the Ag- complex sorbed on the ACC in micropipette was quantitatively eluted by drawing and dispensing of different concentrations of acids for 2 to 5 aspirating/dispensing cycles. The extracted Ag ions with modifier were injected directly into the electrothermal atomic absorption spectrometry for analysis. The influence of different variables on the extraction efficiency, including the concentration of ligand, pH, sample volume, eluent type, concentration and volume was investigated. Validity and accuracy of the developed method was checked by the standard addition method. Reliability of the proposed methodology was checked by the relative standard deviation (%RSD), which was found to be < 5%. Under the optimized experimental variables, the limits of detection (LOD) and enhancement factors (EF), were obtained to be 0.86 ng L- 1 and 120, respectively. The proposed method was successfully applied for the determination of trace levels of silver ions in fresh and waste water samples.

  20. Preconcentration and determination of trace silver ion using benzothiazole calix[4]arene modified silica by flow injection flame atomic absorption spectrometry.

    PubMed

    Waluvanaruk, Jitwilai; Aeungmaitrepirom, Wanlapa; Tuntulani, Thawatchai; Ngamukot, Passapol

    2014-01-01

    The silica gel modified with benzothiazole calix[4]arene (APS-L1) via Schiff's base reaction was applied as a sorbent in an online system for preconcentration and determination of silver ion by flame atomic absorption spectrometry (FAAS). APS-L1 was used as an effective sorbent for solid phase extraction (SPE) of silver(I) ion in both batch and column methods. The optimum experimental parameters such as pH, eluent type, sample flow rate, eluent volume and eluent flow rate including the effect of interfering ions were investigated. Silver(I) ion was determined at pH 6-7. The capacity of APS-L1 sorbent was found to be 12.2 mg/g of sorbent. The high affinity was obtained without interference from the interfering ions. The optimum conditions of the online flow injection preconcentration coupled with the FAAS (FI-FAAS system) were evaluated. The sample flow rate was 3.0 mL min(-1) using sample volume of 5-10 mL. Elution was performed with 250 μL of 0.1 mol L(-1) thiosulfate at the flow rate of 1.5 mL min(-1). The analytical characteristics and performance of the FI-FAAS system were studied under optimum conditions using a solution spiked with standard silver(I) ion at 20 and 50 μg L(-1). The detection limit of 0.44 μg L(-1) was obtained. The accuracy of the proposed method was evaluated and percentages of recovery at 20 and 50 μg L(-1) were 100.2 and 99.5%, respectively. The percent relative standard deviations (%RSD) at 20 and 50 μg L(-1) were 6.1 and 3.3%, respectively. The developed method was successfully applied to determine trace silver(I) ion in drinking and tap water samples.

  1. Application of the extraction induced by emulsion breaking for the determination of chromium and manganese in edible oils by electrothermal atomic absorption spectrometry.

    PubMed

    Robaina, Nicolle F; Brum, Daniel M; Cassella, Ricardo J

    2012-09-15

    This work reports the optimization of a method, based on the extraction induced by emulsion breaking, for the determination of trace concentrations of Cr and Mn in edible oils by electrothermal atomic absorption spectrometry (ETAAS). In the method, a water-in-oil emulsion was prepared by mixing the oil sample with an acid solution (HNO(3)) of Triton X-114 to allow the intense contact between the sample and the extractant acid solution. Afterwards, the emulsion was broken by heating and the acid aqueous phase deposited in the bottom of the flask was collected for the determination of the metals of interest. The method was optimized by studying the influence of several parameters such as the concentration of HNO(3) and the emulsifier agent (Triton X-100 and Triton X-114) in the extractant solution. The best results were verified when the procedure was performed with 5 mL of the sample and 1 mL of the extractant solution containing 15%m/v of Triton X-114 and 2.8 mol L(-1) of HNO(3). Also, the fastest emulsion breaking was verified when the emulsions were heated at 90°C. In these conditions, the emulsions were broken in approximately 10 min. The quantification of Cr and Mn in the extracts was carried out by external calibration with aqueous standard solutions, which simplified the procedure. The limits of detection for the determination of Cr and Mn in the oil samples were 66 and 36 ng L(-1), respectively, and the limits of quantification were 219 and 120 ng L(-1), respectively. The developed method was applied in the determination of Cr and Mn in twelve samples of edible oils produced with different oleaginous. Recovery tests were performed to attest the accuracy of the method, being observed recovery percentages in the range of 86-115%.

  2. Ethylene hydrogenation catalysis on Pt(111) single-crystal surfaces studied by using mass spectrometry and in situ infrared absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Tillekaratne, Aashani; Simonovis, Juan Pablo; Zaera, Francisco

    2016-10-01

    The catalytic hydrogenation of ethylene promoted by a Pt(111) single crystal was studied by using a ultrahigh-vacuum surface-science instrument equipped with a so-called high-pressure cell. Kinetic data were acquired continuously during the catalytic conversion of atmospheric-pressure mixtures of ethylene and hydrogen by using mass spectrometry while simultaneously characterizing the surface species in operando mode by reflection-absorption infrared spectroscopy (RAIRS). Many observations reported in previous studies of this system were corroborated, including the presence of adsorbed alkylidyne intermediates during the reaction and the zero-order dependence of the rate of hydrogenation on the pressure of ethylene. In addition, the high quality of the kinetic data, which could be recorded continuously versus time and processed to calculate time-dependent turnover frequencies (TOFs), afforded a more detailed analysis of the mechanism. Specifically, deuterium labeling could be used to estimate the extent of isotope scrambling reached with mixed-isotope-substituted reactants (C2H4 + D2 and C2D4 + H2). Perhaps the most important new observation from this work is that, although extensive H-D exchange takes place on ethylene before being fully converted to ethane, the average stoichiometry of the final product retains the expected stoichiometry of the gas mixture, that is, four regular hydrogen atoms and two deuteriums per ethane molecule in the case of the experiments with C2H4 + D2. This means that no hydrogen atoms are removed from the surface via their inter-recombination to produce X2 (X = H or D). It is concluded that, under catalytic conditions, hydrogen surface recombination is much slower than ethylene hydrogenation and H-D exchange.

  3. A sensitive magnetic nanoparticle-based immunoassay of phosphorylated acetylcholinesterase using protein cage templated lead phosphate for signal amplification with graphite furnace atomic absorption spectrometry detection.

    PubMed

    Liang, Pei; Kang, Caiyan; Yang, Enjian; Ge, Xiaoxiao; Du, Dan; Lin, Yuehe

    2016-04-07

    We developed a new magnetic nanoparticle sandwich-like immunoassay using protein cage nanoparticles (PCN) for signal amplification together with graphite furnace atomic absorption spectrometry (GFAAS) for the quantification of an organophosphorylated acetylcholinesterase adduct (OP-AChE), the biomarker of exposure to organophosphate pesticides (OPs) and nerve agents. OP-AChE adducts were firstly captured by titanium dioxide coated magnetic nanoparticles (TiO2-MNPs) from the sample matrixes through metal chelation with phospho-moieties, and then selectively recognized by anti-AChE antibody labeled on PCN which was packed with lead phosphate in its cavity (PCN-anti-AChE). The sandwich-like immunoreaction was performed among TiO2-MNPs, OP-AChE and PCN-anti-AChE to form a TiO2-MNP/OP-AChE/PCN-anti-AChE immunocomplex. The complex could be easily isolated from the sample solution with the help of magnet, and the released lead ions from PCN were detected by GFAAS for the quantification of OP-AChE. Greatly enhanced sensitivity was achieved because PCN increased the amount of metal ions in the cavity of each apoferritin. The proposed immunoassay yielded a linear response over a broad range of OP-AChE concentrations from 0.01 nM to 2 nM, with a detection limit of 2 pM, which has enough sensitivity for monitoring of low-dose exposure to OPs. This new method showed an acceptable stability and reproducibility and was validated with OP-AChE spiked human plasma.

  4. Magnetic solid-phase extraction combined with graphite furnace atomic absorption spectrometry for speciation of Cr(III) and Cr(VI) in environmental waters.

    PubMed

    Jiang, Hong-mei; Yang, Ting; Wang, Yan-hong; Lian, Hong-zhen; Hu, Xin

    2013-11-15

    A new approach of magnetic solid phase extraction (MSPE) coupled with graphite furnace atomic absorption spectrometry (GFAAS) has been developed for the speciation of Cr(III) and Cr(VI) using zincon-immobilized silica-coated magnetic Fe3O4 nanoparticles (Zincon-Si-MNPs) as the MSPE absorbent. Cr(III) was quantitatively reserved on the absorbent at pH 9.1 while total Cr was reserved at pH 6.5. The absorbed Cr species were eluted by using 2 mol/L HCl and detected by GFAAS. The concentration of Cr(VI) could be calculated by subtracting Cr(III) from total Cr. All the parameters affecting the separation and extraction efficiency of Cr species such as pH, extraction time, concentration and volume of eluent, sample volume and influence of co-existing ions were systematically examined and the optimized conditions were established accordingly. The detection limit (LOD) of the method was 0.016 and 0.011 ng mL(-1) for Cr(III) and Cr(VI), respectively, with the enrichment factor of 100 and 150. The precisions of this method (Relative standard deviation, RSD, n=7) for Cr(III) and Cr(VI) at 0.1 ng mL(-1) were 6.0% and 6.2%, respectively. In order to validate the proposed method, a certified reference material of environmental water was analyzed, and the result of Cr speciation was in good agreement with the certified value. This MSPE-GFAAS method has been successfully applied for the speciation of Cr(III) and Cr(VI) in lake and tap waters with the recoveries of 88-109% for the spiked samples. Moreover, the MSPE separation mechanism of Cr(III) and Cr(VI) based on their adsorption-desorption on Zincon-Si-MNPs has been explained through various spectroscopic characterization.

  5. Ultrasound-assisted single-drop microextraction for the determination of cadmium in vegetable oils using high-resolution continuum source electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Almeida, Jorge S.; Anunciação, Taiana A.; Brandão, Geovani C.; Dantas, Alailson F.; Lemos, Valfredo A.; Teixeira, Leonardo S. G.

    2015-05-01

    This work presents an ultrasound-assisted single-drop microextraction procedure for the determination of cadmium in vegetable oils using high-resolution continuum source electrothermal atomic absorption spectrometry. Some initial tests showed that the best extraction efficiency was obtained when using ultrasound instead of mechanical agitation, indicating that acoustic cavitation improved the extraction process. Nitric, hydrochloric and acetic acids were evaluated for use in the extraction process, and HNO3 gave the best results. A two-level full-factorial design was applied to investigate the best conditions for the extraction of Cd from the oil samples. The influences of the sonication amplitude, time and temperature of the extraction were evaluated. The results of the design revealed that all of the variables had a significant effect on the experimental results. Afterward, a Box-Behnken design was applied to determine the optimum conditions for the determination of cadmium in vegetable oil samples. According to a multivariate study, the optimum conditions were as follows: sonication amplitude of 60%, extraction time of 15 min, extraction temperature of 46 °C and 0.1 mol L- 1 HNO3 as the extractor solution. Under optimized conditions, the developed method allows for the determination of Cd in oil samples with a limit of quantification of 7.0 ng kg- 1. Addition and recovery experiments were performed in vegetable oil samples to evaluate the accuracy of the method, and the recoveries obtained varied from 90% to 115%. The samples were also analyzed after the acid digestion procedure, and the paired t-test (95% confidence level) did not show significant differences from the proposed method.

  6. Method validation for control determination of mercury in fresh fish and shrimp samples by solid sampling thermal decomposition/amalgamation atomic absorption spectrometry.

    PubMed

    Torres, Daiane Placido; Martins-Teixeira, Maristela Braga; Cadore, Solange; Queiroz, Helena Müller

    2015-01-01

    A method for the determination of total mercury in fresh fish and shrimp samples by solid sampling thermal decomposition/amalgamation atomic absorption spectrometry (TDA AAS) has been validated following international foodstuff protocols in order to fulfill the Brazilian National Residue Control Plan. The experimental parameters have been previously studied and optimized according to specific legislation on validation and inorganic contaminants in foodstuff. Linearity, sensitivity, specificity, detection and quantification limits, precision (repeatability and within-laboratory reproducibility), robustness as well as accuracy of the method have been evaluated. Linearity of response was satisfactory for the two range concentrations available on the TDA AAS equipment, between approximately 25.0 and 200.0 μg kg(-1) (square regression) and 250.0 and 2000.0 μg kg(-1) (linear regression) of mercury. The residues for both ranges were homoscedastic and independent, with normal distribution. Correlation coefficients obtained for these ranges were higher than 0.995. Limits of quantification (LOQ) and of detection of the method (LDM), based on signal standard deviation (SD) for a low-in-mercury sample, were 3.0 and 1.0 μg kg(-1), respectively. Repeatability of the method was better than 4%. Within-laboratory reproducibility achieved a relative SD better than 6%. Robustness of the current method was evaluated and pointed sample mass as a significant factor. Accuracy (assessed as the analyte recovery) was calculated on basis of the repeatability, and ranged from 89% to 99%. The obtained results showed the suitability of the present method for direct mercury measurement in fresh fish and shrimp samples and the importance of monitoring the analysis conditions for food control purposes. Additionally, the competence of this method was recognized by accreditation under the standard ISO/IEC 17025.

  7. In situ emulsification microextraction using a dicationic ionic liquid followed by magnetic assisted physisorption for determination of lead prior to micro-sampling flame atomic absorption spectrometry.

    PubMed

    Shokri, Masood; Beiraghi, Asadollah; Seidi, Shahram

    2015-08-19

    For the first time, a simple and efficient in situ emulsification microextraction method using a dicationic ionic liquid followed by magnetic assisted physisorption was presented to determine trace amounts of lead. In this method, 400 μL of 1.0 mol L(-1) lithium bis (trifluoromethylsulfonyl) imide aqueous solution, Li[NTf2], was added into the sample solution containing 100 μL of 1.0 mol L(-1) 1,3-(propyl-1,3-diyl) bis (3-methylimidazolium) chloride, [pbmim]Cl2, to form a water immiscible ionic liquid, [pbmim][NTf2]2. This new in situ formed dicationic ionic liquid was applied as the acceptor phase to extract the lead-ammonium pyrrolidinedithiocarbamate (Pb-APDC) complexes from the sample solution. Subsequently, 30 mg of Fe3O4 magnetic nanoparticles (MNPs) were added into the sample solution to collect the fine droplets of [pbmim][NTf2]2, physisorptively. Finally, MNPs were eluted by acetonitrile, separated by an external magnetic field and the obtained eluent was subjected to micro-sampling flame atomic absorption spectrometry (FAAS) for further analysis. Comparing with other microextraction methods, no special devices and centrifugation step are required. Parameters influencing the extraction efficiency such as extraction time, pH, concentration of chelating agent, amount of MNPs and coexisting interferences were studied. Under the optimized conditions, this method showed high extraction recovery of 93% with low LOD of 0.7 μg L(-1). Good linearity was obtained in the range of 2.5-150 μg L(-1) with determination coefficient (r(2)) of 0.9921. Relative standard deviation (RSD%) for seven repeated measurements at the concentration of 10 μg L(-1) was 4.1%. Finally, this method was successfully applied for determination of lead in some water and plant samples.

  8. Determination of copper and mercury in phosphate fertilizers employing direct solid sampling analysis and high resolution continuum source graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    de Oliveira Souza, Sidnei; François, Luciane Luiza; Borges, Aline Rocha; Vale, Maria Goreti Rodrigues; Araujo, Rennan Geovanny Oliveira

    2015-12-01

    The present study proposes the determination of copper and mercury in phosphate fertilizers by direct solid sampling analysis (SS) employing high resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS). For Cu determination, two analytical lines were used: 327.3960 nm and 249.2146 nm. Hg determination was carried out on the line 253.6521 nm and 100 μg KMnO4 was used as chemical modifier. The optimal pyrolysis temperature for Cu determination was 1300 °C. Atomization temperatures for Cu and Hg were 2400 and 1100 °C, respectively. External calibration with aqueous standard solutions was adopted for both elements. The limits of quantification (LoQs) and characteristic mass (m0) obtained for Cu determination were 0.4 μg g- 1 and 1.12 ng, respectively, on line 249.2146 nm, and 64 μg g- 1 and 25 pg on 327.3960 nm. For mercury, LoQ and m0 were 4.8 ng g- 1 and 39 pg, respectively. The accuracy of the proposed methods was confirmed by the analysis of standard reference material (SRM) of Trace Elements in Multi-Nutrient Fertilizer (SRM NIST 695). The precision expressed as relative standard deviation (RSD), was better than 8.2% for Hg and 7.7% for the Cu (n = 5), considered satisfactory for microanalysis in solid sample. Four fertilizer samples acquired in commercial establishments in the city of Salvador, Bahia, Brazil, were analyzed. The optimized analytical methods were simple, fast, accurate, precise and free of spectral interferences for the determination of Cu and Hg in phosphate fertilizer samples by SS-HR-CS GF AAS, avoiding the dissolution of the sample, the use of harmful reagents and the generation of residues.

  9. On the possibilities of high-resolution continuum source graphite furnace atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple atomic lines

    NASA Astrophysics Data System (ADS)

    Resano, M.; Rello, L.; Flórez, M.; Belarra, M. A.

    2011-05-01

    This paper explores the potential of commercially available high-resolution continuum source graphite furnace atomic absorption spectrometry instrumentation for the simultaneous or sequential monitoring of various atomic lines, in an attempt to highlight the analytical advantages that can be derived from this strategy. In particular, it is demonstrated how i) the monitoring of multiplets may allow for the simple expansion of the linear range, as shown for the measurement of Ni using the triplet located in the vicinity of 234.6 nm; ii) the use of a suitable internal standard may permit improving the precision and help in correcting for matrix-effects, as proved for the monitoring of Ni in different biological samples; iii) direct and multi-element analysis of solid samples may be feasible on some occasions, either by monitoring various atomic lines that are sufficiently close (truly simultaneous monitoring, as demonstrated in the determination of Co, Fe and Ni in NIST 1566a Oyster tissue) or, alternatively, by opting for a selective and sequential atomization of the elements of interest during every single replicate. Determination of Cd and Ni in BCR 679 White cabbage is attempted using both approaches, which permits confirming that both methods can offer very similar and satisfactory results. However, it is important to stress that the second approach provides more flexibility, since analysis is no longer limited to those elements that show very close atomic lines (closer than 0.3 nm in the ultraviolet region) with a sensitivity ratio similar to the concentration ratio of the analytes in the samples investigated.

  10. Spatial distribution and speciation of arsenic in peat studied with Microfocused X-ray fluorescence spectrometry and X-ray absorption spectroscopy.

    PubMed

    Langner, Peggy; Mikutta, Christian; Suess, Elke; Marcus, Matthew A; Kretzschmar, Ruben

    2013-09-03

    Arsenic binding by sulfhydryl groups of natural organic matter (NOM) was recently identified as an important As sequestration pathway in the naturally As-enriched minerotrophic peatland Gola di Lago, Switzerland. Here, we explore the microscale distribution, elemental correlations, and chemical speciation of As in the Gola di Lago peat. Thin sections of undisturbed peat samples from 0-37 cm and 200-249 cm depth were analyzed by synchrotron microfocused X-ray fluorescence (μ-XRF) spectrometry and X-ray absorption spectroscopy (μ-XAS). Additionally, peat samples were studied by bulk As, Fe, and S K-edge XAS. Micro-XRF analyses showed that As in the near-surface peat was mainly concentrated in 10-50 μm sized hotspots, identified by μ-XAS as realgar (α-As4S4). In the deep peat layer samples, however, As was more diffusely distributed and mostly associated with particulate NOM of varying decomposition stages. The NOM-associated As was present as trivalent As bound by sulfhydryl groups. Arsenopyrite (FeAsS) and arsenian pyrite (FeAsxS2-x) of <25 μm size, which have escaped detection by bulk As and Fe K-edge XAS, were found as minor As species in the peat. Bulk S K-edge XAS revealed that the deep peat layers were significantly enriched in reduced organic S species. Our findings suggest an authigenic formation of realgar and arsenopyrite in strongly reducing microenvironments of the peat and indicate that As(III)-NOM complexes are formed by the passive sorption of As(III) to NOM. This reaction appears to be favored by a combination of abundant reduced organic S and comparatively low As solution concentrations preventing the formation of secondary As-bearing sulfides.

  11. A study of the distribution of aluminum in human placental tissues based on alkaline solubilization with determination by electrothermal atomic absorption spectrometry

    PubMed Central

    Kruger, Pamela C.; Schell, Lawrence M.; Stark, Alice D.; Parsons, Patrick J.

    2010-01-01

    Summary Aluminum (Al) is a nonessential element known to induce neurotoxic effects, such as dialysis dementia, in patients on hemodialysis, with compromised kidney function. The role of Al in the progression of some neurodegenerative diseases, such as Alzheimer’s disease (AD), is controversial, and remains unclear. The effects of Al on other vulnerable populations, such as fetuses and infants, have been infrequently studied. In the present study, Al has been measured in human placenta samples, comprising ~160 each of placenta bodies, placenta membranes, and umbilical cords, using electrothermal atomic absorption spectrometry (ETAAS) after atmospheric pressure digestion with tetramethylammonium hydroxide (TMAH) and ethylenediaminetetraacidic acid (EDTA). The sensitivity, or characteristic mass (m0), for Al at the 309.3-nm line was found to be 30 ± 4 pg. The instrumental detection limit (IDL) (3s) for Al in solution was calculated as 0.72 μg L-1, while the method detection limit (MDL) (3s) was 0.25 μg g-1. Accuracy was assessed through analysis of quality control (QC) materials, including certified reference materials (CRMs), in-house reference materials (RMs), and spike recovery experiments, of varying matrices. Placental tissue analyses revealed geometric mean concentrations of approximately 0.5 μg g-1 Al in placenta bodies (n=165) and membranes (n=155), while Al concentrations in the umbilical cord (n=154) were about 0.3 μg g-1. Al was detected in 95% of placenta bodies, and 81% of placenta membranes, but only in 46% of umbilical cords. PMID:21072353

  12. A dried urine spot test to simultaneously monitor Mo and Ti levels using solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Rello, L.; Lapeña, A. C.; Aramendía, M.; Belarra, M. A.; Resano, M.

    2013-03-01

    Home-based collection protocols for clinical specimens are actively pursued as a means of improving life quality of patients that require frequent controls, such as patients with metallic prosthesis, for whom monitoring the evolution of Mo and Ti in biological fluids may play a decisive role to detect prosthesis mal-functioning. The collection of biological fluids on clinical filter papers provides a simple way to implement these protocols. This work explores the potential of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry for the simultaneous and direct determination of Mo and Ti in urine, after its deposition onto clinical filter paper, giving rise to a dried urine spot. The approach used for depositing the sample was found crucial to develop a quantitative method, since the filter paper acts as a chromatographic support and produces a differential distribution of the target analytes. Furthermore, the high spreading of urine onto a filter paper results in a small amount of urine per surface unit, and thus, ultimately, in lack of sensitivity. In order to circumvent these problems, the use of an alternative approach based on the use of pre-cut 17 × 19 mm filter paper pieces onto which larger amounts of sample (500 μL) can be retained by single deposition was proposed and evaluated. In this way, an approximately 12-fold increase in sensitivity and a more homogeneous distribution of the target analytes were obtained, permitting the development of a quantification strategy based on the use of matrix-matched urine samples of known analyte concentrations, which were subjected to the same procedure as the samples. Accuracy of this method, which provides LODs of 1.5 μg L- 1 for Mo and 6.5 μg L- 1 for Ti, was demonstrated after analysis of urine reference materials. Overall, the performance of the method developed is promising, being likely suitable for determination of other analytes in dried urine spots.

  13. Ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry for a sensitive determination of cadmium in water samples

    NASA Astrophysics Data System (ADS)

    Li, Shengqing; Cai, Shun; Hu, Wei; Chen, Hao; Liu, Hanlan

    2009-07-01

    A new method was developed for the determination of cadmium in water samples using ionic liquid-based ultrasound-assisted dispersive liquid-liquid microextraction (IL-based USA-DLLME) followed by electrothermal atomic absorption spectrometry (ETAAS). The IL-based USA-DLLME procedure is free of volatile organic solvents, and there is no need for a dispersive solvent, in contrast to conventional DLLME. The ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate (HMIMPF 6), was quickly disrupted by an ultrasonic probe for 1 min and dispersed in water samples like a cloud. At this stage, a hydrophobic cadmium-DDTC complex was formed and extracted into the fine droplets of HMIMPF 6. After centrifugation, the concentration of the enriched cadmium in the sedimented phase was determined by ETAAS. Some effective parameters of the complex formation and microextraction, such as the concentration of the chelating agent, the pH, the volume of the extraction solvent, the extraction time, and the salt effect, have been optimized. Under optimal conditions, a high extraction efficiency and selectivity were reached for the extraction of 1.0 ng of cadmium in 10.0 mL of water solution employing 73 µL of HMIMPF 6 as the extraction solvent. The enrichment factor of the method is 67. The detection limit was 7.4 ng L - 1 , and the characteristic mass ( m0, 0.0044 absorbance) of the proposed method was 0.02 pg for cadmium (Cd). The relative standard deviation (RSD) for 11 replicates of 50 ng L - 1 Cd was 3.3%. The method was applied to the analysis of tap, well, river, and lake water samples and the Environmental Water Reference Material GSBZ 50009-88 (200921). The recoveries of spiked samples were in the range of 87.2-106%.

  14. On-line filtration system for determining total chromium and chromium in the soluble fraction of industrial effluents by flow injection flame atomic absorption spectrometry.

    PubMed

    López-García, I; Merino Meroño, B; Campillo, N; Hernández-Córdoba, M

    2002-05-01

    Two manifolds were assessed for the purpose of determining both the total chromium content and that present as a soluble form in industrial effluents by flow injection flame atomic absorption spectrometry (FI-FAAS). To determine the chromium content in the soluble fraction the samples were used without additional treatment, a 0.45 microm filter being included in the FI system. To determine the total chromium content, the samples were acidified with nitric acid 20% (v/v) and heated for 30 s in a microwave oven (temperatures of about 70 degrees C were reached). The problem posed by the very different concentration range in which total and soluble chromium are present was overcome by using programmed flow rate methodology and by only partially emptying the sample loop. A personal computer controlled both the rotation speed of a peristaltic pump and the volume of sample injected into the system, thus obtaining the dispersion degree required. Using the manifold proposed, the chromium content in the soluble fraction can be determined in the 0.5-20 microg mL(-1) range using a 10 microg mL(-1) single standard for calibration. To determine the total chromium content, a calibration line in the 20-200 microg mL(-1) range was obtained using a single 50 microg mL(-1) chromium standard solution. The reliability of the semi-automatic devices was verified by comparing the results obtained with those found by treating the samples and using both FAAS in a conventional way and a spectrophotometric method using diphenylcarbazide at the 95% confidence level (ANOVA test). The proposed procedures showed a RSD lower than +/-3%.

  15. Determination of trace amounts of Pd(II) ions in water and road dust samples by flame atomic absorption spectrometry after preconcentration on modified organo nanoclay.

    PubMed

    Afzali, Daryoush; Mostafavi, Al; Afzali, Zahra

    2010-01-01

    This paper describes the application of organo nanoclay, an easily prepared and stable solid sorbent, to the preconcentration of trace amounts of palladium ions in aqueous solution. The organo nanoclay was prepared by adding tetradecyldimethylbenzylamonium chloride onto montmorillonite, which was then modified with 1-(2-pyridylazo)-2-naphthol. The modified nanoclay was used as a solid sorbent for separation and preconcentration of trace amounts of Pd(II) ions, and a simple, sensitive, and economical method was developed for determination of trace amounts of palladium by flame atomic absorption spectrometry. The sorption of Pd(II) ions was quantitative in the pH range of 1.5-5.0, whereas quantitative desorption occurred with 5.0 mL of a mixture containing 1.0 M thiourea and 1.0 M HCl. The RSD of the method was +/- 2.1% (n = 10; concn = 0.5 microg/mL), and the LOD (3sigma(bl); sigma = SD and bl = blank) was 0.1 ng/mL. The calibration curve was linear for concentrations of 0.5-8.0 microg/mL in the initial solution, and the preconcentration factor was 140. The maximum capacity of the sorbent was 2.4 mg Pd(II)/g modified organo nanoclay. The influences of the experimental parameters, including sample pH, eluant volume, eluant type, sample volume, and interfering ions, on the recoveries of the palladium ion were investigated. The proposed method was applied to the preconcentration and determination of palladium in different samples.

  16. Combining single-particle inductively coupled plasma mass spectrometry and X-ray absorption spectroscopy to evaluate the release of colloidal arsenic from environmental samples.

    PubMed

    Gomez-Gonzalez, Miguel Angel; Bolea, Eduardo; O'Day, Peggy A; Garcia-Guinea, Javier; Garrido, Fernando; Laborda, Francisco

    2016-07-01

    Detection and sizing of natural colloids involved in the release and transport of toxic metals and metalloids is essential to understand and model their environmental effects. Single-particle inductively coupled plasma mass spectrometry (SP-ICP-MS) was applied for the detection of arsenic-bearing particles released from mine wastes. Arsenic-bearing particles were detected in leachates from mine wastes, with a mass-per-particle detection limit of 0.64 ng of arsenic. Conversion of the mass-per-particle information provided by SP-ICP-MS into size information requires knowledge of the nature of the particles; therefore, synchrotron-based X-ray absorption spectroscopy (XAS) was used to identify scorodite (FeAsO4·2H2O) as the main species in the colloidal particles isolated by ultrafiltration. The size of the scorodite particles detected in the leachates was below 300-350 nm, in good agreement with the values obtained by TEM. The size of the particles detected by SP-ICP-MS was determined as the average edge of scorodite crystals, which show a rhombic dipyramidal form, achieving a size detection limit of 117 nm. The combined use of SP-ICP-MS and XAS allowed detection, identification, and size determination of scorodite particles released from mine wastes, suggesting their potential to transport arsenic. Graphical abstract Analytical approach for the detection and size characterization of As-bearing particles by SP-ICP-MS and XAS in environmental samples.

  17. Sequential determination of Cd and Cr in biomass samples and their ashes using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis.

    PubMed

    Duarte, Alvaro T; Dessuy, Morgana B; Vale, Maria Goreti R; Welz, Bernhard; de Andrade, Jailson B

    2013-10-15

    High-resolution continuum source graphite furnace atomic absorption spectrometry, because of the use of only one radiation source for all elements, offers the possibility of sequential determination of two or more elements from the same sample aliquot if their volatilities are significantly different. Cd and Cr were determined sequentially in samples of biomass and biomass ashes employing direct solid sample analysis. The use of a chemical modifier was found to be not necessary, and calibration could be carried out using aqueous standard solutions. A pyrolysis temperature of 400°C and an atomization temperature of 1500°C were used for the determination of Cd; no losses of Cr were observed at this temperature. After the atomization of Cd the wavelength was changed and Cr atomized at 2600°C. The limits of detection (LOD) and quantification (LOQ) were 1.1 μg kg(-1) and 3.7 μg kg(-1), respectively, for Cd and 21 μg kg(-1) and 70 μg kg(-1), respectively, for Cr using the most sensitive line at 357.869 nm, or 90 μg kg(-1) and 300 μg kg(-1), respectively, using the less sensitive line at 428.972 nm. The precision, expressed as relative standard deviation was around 10%, which is typical for direct solid sample analysis. The values found for Cd in biomass samples were between <1.1 µg kg(-1) and 789 µg kg(-1), whereas those for Cr were between 7.9 mg kg(-1) and 89 mg kg(-1); the values found in the ashes were significantly lower for Cd, between <1.1 µg kg(-1) and 6.3 µg kg(-1), whereas the trend was not so clear for Cr, where the values were between 3.4 mg kg(-1) and 28 mg kg(-1).

  18. Correlation between ultra-high performance liquid chromatography-tandem mass spectrometry and reversed-phase thin-layer chromatography hydrophobicity data for evaluation of angiotensin-converting enzyme inhibitors absorption.

    PubMed

    Odovic, Jadranka V; Markovic, Bojan D; Injac, Rade D; Vladimirov, Sote M; Karljikovic-Rajic, Katarina D

    2012-10-05

    In this research seven ACE inhibitors (enalapril, quinapril, fosinopril, lisinopril, cilazapril, ramipril, benazepril) were studied to evaluate the correlation between their absorption and ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS) and reversed-phase thin-layer chromatography (RP-TLC) hydrophobicity data (φ(0) or C(0) parameters, respectively). Their absorption values were in the range of 25-60%, while calculated KOWWIN logP values were from -0.94 to 6.61. Additionally, perindopril (absorption 70%, KOWWIN logP 2.59) and moexipril (absorption 22%, KOWWIN logP 3.36) were introduced for the theoretical considerations due to their high/low absorption values which were on the opposite sites in comparison with the majority of ACE inhibitors (25-60%). In the theoretical considerations it was shown that the solubility data (logS) must be considered, as independent variable, simultaneously with KOWWIN logP to obtain reliable correlation (r(2)=0.7208) between absorption and ACE inhibitors lipophilicity. As the main topic of this study, the relationships between literature available and absorption data predicted by multiple linear regression (MLR) using logS values besides chromatographically obtained hydrophobicity parameters C(0) (r(2)=0.6424) or φ(0) (r(2)=0.6762) were studied proving that these parameters could be used in ACE inhibitors absorption evaluation. The UHPLC-MS method provides the direct application of experimentally obtained φ(0) values that is the advantage of this method. For better MLR correlation of ACE inhibitors absorption with C(0) parameters (RP-TLC) and logS, mathematical conversion of C(0) parameters to logC(0) values was necessary based on requisite for probability value of regression analysis (P<0.05). The accordance and differences between hydrophobicity parameters obtained by UHPLC-MS and RP-TLC were defined.

  19. Investigation of an alternating current plasma as an element selective atomic emission detector for high-resolution capillary gas chromatography and as a source for atomic absorption and atomic emission spectrometry

    SciTech Connect

    Ombaba, J.M.

    1992-01-01

    This thesis deals with the construction and evaluation of an alternating current plasma (ACP) as an element-selective detector for high resolution capillary gas chromatography (GC) and as an excitation source for atomic absorption spectrometry (AAS) and atomic emission spectrometry (AES). The plasma, constrained in a quartz discharge tube at atmospheric pressure, is generated between two copper electrodes and utilizes helium as the plasma supporting gas. The alternating current plasma power source consists of a step-up transformer with a secondary output voltage of 14,000 V at a current of 23 mA. The chromatographic applications studied included the following: (1) the separation and selective detection of the organotin species, tributyltin chloride (TBT) and tetrabutyltin (TEBT), in environmental matrices including mussels (mytilus edullus) and sediment from Boston Harbor, industrial waste water and industrial sludge, and (2) the detection of methylcyclopentadienylmanganesetricarbonyl (MMT) and similar compounds used as gasoline additives. An ultrasonic nebulizer was utilized as a sample introduction device for aqueous solutions when the ACP was employed as an atomization source for atomic absorption spectrometry and as an excitation source for atomic emission spectrometry. Plasma diagnostic parameters studied include spatial electron number density across the discharge tube, electronic, excitation and ionization temperatures. Interference studies both in absorption and emission modes were considered. The evaluation of a computer-aided optimization program, Drylab GC, using spearmint oil and Environmental Protection Agency (EPA) standard mixture as probes is discussed. The program is used for separation optimization and prediction of gas chromatographic parameters. The program produces a relative resolution map (RRM) which guides the analyst in selecting the most favorable temperature programming rate for the separation.

  20. Improved microwave-assisted wet digestion procedures for accurate Se determination in fish and shellfish by flow injection-hydride generation-atomic absorption spectrometry.

    PubMed

    Lavilla, I; González-Costas, J M; Bendicho, C

    2007-05-22

    Accurate determination of Se in biological samples, especially fish and shellfish, by hydride generation techniques has generally proven troublesome owing to the presence of organoselenium that cannot readily converted into inorganic selenium under usual oxidising conditions. Further improvements in the oxidation procedures are needed so as to obtain accurate concentration values when this type of samples is analyzed. Microwave-assisted wet digestion (MAWD) procedures of seafood based on HNO3 or the mixture HNO3/H2O2 and further thermal reduction of the Se(VI) formed to Se(IV) were evaluated. These procedures were as follows: (I) without H2O2 and without heating to dryness; (II) without H2O2 and with heating to dryness; (III) with H2O2 and without heating to dryness; (IV) with H2O2 and with heating to dryness. In general, low recoveries of selenium are obtained for several marine species (e.g., crustaceans and cephalopods), which may be ascribed to the presence of Se forms mainly associated with nonpolar proteins and lipids. Post-digestion UV irradiation proved very efficient since not only complete organoselenium decomposition was achieved but also the final step required for prereduction of Se(VI) into Se(IV) (i.e. heating at 90 degrees C for 30 min in 6M HCl) could be avoided. With the MAWD/UV procedure, the use of strong oxidising agents (persuphate, etc.) or acids (e.g. perchloric acid) which are typically applied prior to Se determination by hydride generation techniques is overcome, and as a result, sample pre-treatment is significantly simplified. The method was successfully validated against CRM DOLT-2 (dogfish liver), CRM DORM-2 (dogfish muscle) and CRM TORT-2 (lobster hepatopancreas). Automated ultrasonic slurry sampling with electrothermal atomic absorption spectrometry was also applied for comparison. Total Se contents in ten seafood samples were established. Se levels ranged from 0.7 to 2.9 microg g(-1).

  1. Marine sediments monitoring studies for trace elements with the application of fast temperature programs and solid sampling high resolution continuum source atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Orani, Anna Maria; Han, Eunmi; Mandjukov, Petko; Vassileva, Emilia

    2015-01-01

    Analytical procedure for the determination of As, Cd, Cu, Ni, Co and Cr in marine sediment samples using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS AAS) and direct solid sample analysis has been developed. The application of fast programs in combination with direct solid sampling allows to eliminate the drying and pretreatment steps, however makes impossible the use of liquid standards for calibration. Iridium treated platforms were applied throughout the present study. Calibration technique based on the use of solid certified reference materials (marine sediments) similar to the nature of the analyzed sample and statistics of regression analysis were applied to the real sediment samples. The instrumental parameters were optimized in order to obtain reproducible and interference free analytical signals. The ISO-17025 requirements and Eurachem guidelines were followed in the validation of the proposed analytical procedure. Accordingly, blanks, selectivity, calibration, linearity, working range, trueness, repeatability reproducibility, limits of detection and quantification and expanded uncertainty (k = 2) for all investigated elements were assessed. Two different approaches for the estimation of measurement uncertainty were applied and obtained results compared. The major contributors to the combined uncertainty of the analyte mass fraction were found to be the homogeneity of the samples and the microbalance precision. The influence of sample particle sizes on the total combined uncertainty was also evaluated. Traceability to SI system of units of the obtained by the proposed analytical procedure results was demonstrated. Additionally, validation of the methodology developed was effectuated by the comparison of the obtained results with independent method e.g. ICP-MS with external calibration. The use of solid sampling HR CS AAS for the determination of trace elements in marine sediment matrix gives significant advantages

  2. On-line UV-photooxidation with peroxodisulfate for automated flow injection and for high-performance liquid chromatography coupled to hydride generation atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Tsalev, Dimiter L.; Sperling, Michael; Welz, Bernhard

    2000-04-01

    An automated on-line UV photooxidation with peroxodisulfate of some environmentally relevant organoarsenic and organotin compounds in a system built from commercially available modules has been studied and optimised with a view to both species-independent quantification of the total arsenic or tin in samples containing different organic species by flow injection hydride generation atomic absorption spectrometry (FI-HGAAS) and speciation analysis by coupled high-performance liquid chromatography (HPLC) with HGAAS detection. For organoarsenicals, the reaction with alkaline peroxodisulfate in a 10-15-m knotted reactor for >1.5 min insures >90% transformation of inorganic As(III) and six organoarsenic species to arsenate: monomethylarsonate, dimethylarsinate, arsenobetaine, arsenocholine, trimethylarsine oxide and tetramethylarsonium. For organotins, the UV photooxidation with acidic peroxodisulfate at 95-100°C provides recoveries of >80% for the inorganic tin, dimethyltin, trimethyltin, triethyltin, tripropyltin, triphenyltin, monobutyltin, dibutyltin and tributyltin but only approximately 15% for tetrabutyltin. The best characteristic masses in integrated absorbance ( Aint) and peak-height ( Ap) measurements, respectively, are 30 pg and 480 pg for arsenic(V) and 22 pg and 410 pg for tin(IV), employing 100-μl injections. The RSDs are 5.5% and 8.5% at 5 ng As(V) levels and 4.3% and 6.4% at 10 ng Sn(IV) levels in Aint and Ap modes, respectively. The limits of detection (LOD, 3σ) for As are 7 μg l -1 and 4 μg l -1 in FI-UV-HGAAS and HPLC-UV-HGAAS, respectively. The LODs for i-Sn(IV) are 2 μg l -1 in FI-UV-HGAAS, with both Aint and Ap measurements. The sample throughput rates are 20 and 12 samples per hour with 10-m and 15-m knotted reactors (i.d. 0.5 mm), respectively. Urine certified reference materials containing 0.052-0.48 μg ml -1 As have been analysed for their total arsenic content.

  3. Method development for the determination of cadmium in fertilizer samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and slurry sampling

    NASA Astrophysics Data System (ADS)

    Borges, Aline R.; Becker, Emilene M.; Lequeux, Céline; Vale, Maria Goreti R.; Ferreira, Sergio L. C.; Welz, Bernhard

    2011-07-01

    The determination of cadmium (Cd) in fertilizers is of major interest, as this element can cause growth problems in plants, and also affect animals and humans. High-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) with charge-coupled device (CCD) array detection overcomes several of the limitations encountered with conventional line source AAS, especially the problem of accurate background measurement and correction. In this work an analytical method has been developed to determine Cd in fertilizer samples by HR-CS GF AAS using slurry sampling. Both a mixture of 10 μg Pd + 6 μg Mg in solution and 400 μg of iridium as permanent modifier have been investigated and aqueous standards were used for calibration. Pyrolysis and atomization temperatures were 600 °C and 1600 °C for the Pd-Mg modifier, and 500 °C and 1600 °C for Ir, respectively. The results obtained for Cd in the certified reference material NIST SRM 695 (Trace Elements in Multi-Nutrient Fertilizer) of 16.7 ± 1.3 μg g -1 and 16.4 ± 0.75 μg g -1 for the Pd-Mg and Ir modifier, respectively, were statistically not different from the certified value of 16.9 ± 0.2 μg g -1 on a 95% confidence level; however, the results obtained with the Ir modifier were significantly lower than those for the Pd-Mg modifier for most of the samples. The characteristic mass was 1.0 pg for the Pd-Mg modifier and 1.1 pg Cd for the Ir modifier, and the correlation coefficients (R 2) of the calibration were > 0.99. The instrumental limits of detection were 7.5 and 7.9 ng g -1, and the limits of quantification were 25 and 27 ng g -1 for Pd-Mg and Ir, respectively, based on a sample mass of 5 mg. The cadmium concentration in the investigated samples was between 0.07 and 5.5 μg g -1 Cd, and hence below the maximum value of 20 μg g -1 Cd permitted by Brazilian legislation.

  4. Metal interferences and their removal prior to the determination of As(T) and As(III) in acid mine waters by hydride generation atomic absorption spectrometry

    USGS Publications Warehouse

    McCleskey, R. Blaine; Nordstrom, D. Kirk; Ball, James W.

    2003-01-01

    Hydride generation atomic absorption spectrometry (HGAAS) is a sensitive and selective method for the determination of total arsenic (arsenic(III) plus arsenic(V)) and arsenic(III); however, it is subject to metal interferences for acid mine waters. Sodium borohydride is used to produce arsine gas, but high metal concentrations can suppress arsine production. This report investigates interferences of sixteen metal species including aluminum, antimony(III), antimony(V), cadmium, chromium(III), chromium(IV), cobalt, copper(II), iron(III), iron(II), lead, manganese, nickel, selenium(IV), selenium(VI), and zinc ranging in concentration from 0 to 1,000 milligrams per liter and offers a method for removing interfering metal cations with cation exchange resin. The degree of interference for each metal without cation-exchange on the determination of total arsenic and arsenic(III) was evaluated by spiking synthetic samples containing arsenic(III) and arsenic(V) with the potential interfering metal. Total arsenic recoveries ranged from 92 to 102 percent for all metals tested except antimony(III) and antimony(V) which suppressed arsine formation when the antimony(III)/total arsenic molar ratio exceeded 4 or the antimony(V)/total arsenic molar ratio exceeded 2. Arsenic(III) recoveries for samples spiked with aluminum, chromium(III), cobalt, iron(II), lead, manganese, nickel, selenium(VI), and zinc ranged from 84 to 107 percent over the entire concentration range tested. Low arsenic(III) recoveries occurred when the molar ratios of metals to arsenic(III) were copper greater than 120, iron(III) greater than 70, chromium(VI) greater than 2, cadmium greater than 800, antimony(III) greater than 3, antimony(V) greater than 12, or selenium(IV) greater than 1. Low recoveries result when interfering metals compete for available sodium borohydride, causing incomplete arsine production, or when the interfering metal oxidizes arsenic(III). Separation of interfering metal cations using

  5. Direct determination of Hg in polymers by solid sampling-graphite furnace atomic absorption spectrometry. A comparison of the performance of line source and continuum source instrumentation

    NASA Astrophysics Data System (ADS)

    Resano, M.; Briceño, J.; Belarra, M. A.

    2009-06-01

    This work explores the potential of solid sampling-graphite furnace atomic absorption spectrometry (SS-GFAAS) for the fast and direct determination of Hg in polymers. Eight certified reference materials with different composition (polyethylene-PE-, polystyrene-PS-, poly vinyl chloride-PVC- and acrylonitrile butadiene styrene-ABS-) were selected for the study, covering a wide Hg content range (from 20 to 1100 μg g - 1 ). The difficulties found in achieving a selective atomization of the analyte from these samples were partially mitigated by the maintenance of the Ar flow during the atomization step, leading to an improved signal-to-background ratio. Even then, when a line source (LS) GFAAS instrument was employed for analysis, it was only possible to develop truly accurate procedures relying on the use of aqueous standards for calibration for PE and PVC samples, and different atomization conditions (1200 °C and 1300 °C, respectively) were needed for the two types of samples. The use of high-resolution continuum source (HR-CS) GFAAS instrumentation permitted to improve this situation significantly thanks to its higher potential for the correction of high and fast changing background. With such an instrument, satisfactory results could be obtained for all the samples under study using the same atomization conditions (1200 °C) and aqueous standard solutions for calibration. Additionally, the HR-CS GFAAS technique presented a lower limit of detection (0.6 μg g - 1 for CS and 2.2 μg g - 1 for LS), a broader linear range (10 to 320 Hg ng for CS, and 20 to 200 ng for LS), and a somewhat improved sensitivity (approximately 0.0030 s ng - 1 for CS using the three central pixels for quantification, and approximately 0.0025 s ng - 1 for LS). Overall, the use of HR-CS GFAAS permits obtaining significant advantages for the determination of this complex analyte in plastics, such as straightforward calibration with aqueous standards, a high sample throughput (15 min per

  6. Graphene oxide-TiO2 composite solid phase extraction combined with graphite furnace atomic absorption spectrometry for the speciation of inorganic selenium in water samples.

    PubMed

    Zhang, Yanan; Chen, Beibei; Wu, Shaowei; He, Man; Hu, Bin

    2016-07-01

    In this paper, a method of graphene oxide (GO)-TiO2 composite solid phase extraction followed by graphite furnace atomic absorption spectrometry (GFAAS) detection was proposed for the speciation of inorganic selenium in environmental waters. The adsorption behavior of inorganic Se(IV) and Se(VI) on the GO-TiO2(1:1) composite was investigated. It was found that Se(IV) was quantitatively retained on the GO-TiO2 composites within a wide pH range of 0.5-10, while Se(VI) was quantitatively adsorbed on GO-TiO2(1:1) composite at pH 0.5-2, and no obvious adsorption of Se(VI) within the pH range of 4-10 was found. By selecting pH 6.0, Se(IV) could be easily determined. After reduction of Se(VI), total Se was determined by the proposed method, and Se(VI) was calculated as the difference between the total Se and Se(IV). The factors affecting the separation/preconcentration of Se(IV) and Se(VI) were studied. Under the optimum conditions, the isothermal adsorption of Se(IV) on the GO-TiO2(1:1) composite fitted Langmuir model; a linear range over 0.1-12ngmL(-1) was obtained. The limit of detection (LOD) and precision of the method for Se(IV) was 0.04ngmL(-1) and 9.4% (cSe(IV)=0.5ngmL(-1), n=7), respectively. In order to verify the accuracy of the method, a standard water sample (GSBZ50031-94) was analyzed, and the determined value was in a good agreement to the certified value. The established method was applied to inorganic Se speciation in environmental water samples and the recovery of 87.4-102% was obtained for the spiked samples.

  7. Ion Imprinted Polymer for Preconcentration and Determination of Ultra-Trace Cadmium, Employing Flow Injection Analysis with Thermo Spray Flame Furnace Atomic Absorption Spectrometry.

    PubMed

    do Lago, Ayla Campos; Marchioni, Camila; Mendes, Tássia Venga; Wisniewski, Célio; Fadini, Pedro Sergio; Luccas, Pedro Orival

    2016-11-01

    This work proposes a preconcentration method using an ion imprinted polymer (IIP) for determination of cadmium, in several samples, employing a mini-column filled with the polymer coupled into a flow injection analysis system with detection by thermospray flame furnace atomic absorption spectrometry (FIA-TS-FF-AAS). The polymer was synthesized via bulk using methacrylic acid and vinylimidazole as a functional monomer. For the FIA system initial assessment, the variables: pH, eluent concentration and buffer concentration were studied, employing a 23 full factorial design. To obtain the optimum values for each significant variable, a Doehlert matrix was employed. After the optimization conditions as: pH 5.8, eluent (HNO3) concentration of 0.48 mol L(-1) and buffer concentration of 0.01 mol L(-1), were adopted. The proposed method showed a linear response in the range of 0.081-10.0 μg L(-1), limits detection and quantification of 0.024 and 0.081 μg L(-1), respectively; preconcentration factor of 165, consumptive index of 0.06 mL, concentration efficiency 132 min(-1), and frequency of readings equal to 26 readings h(-1) The accuracy was checked by analysis of certified reference materials for trace metals and recovery tests. The obtained results were in agreement with 95% confidence level (t-test). The method was adequate to apply in samples of: jewelry (earrings) (2.38 ± 0.28 μg kg(-1)), black tea (1.09 ± 0.15 μg kg(-1)), green tea (3.85 ± 0.13 μg kg(-1)), cigarette tobacco (38.27 ± 0.22 μg kg(-1)), and hair (0.35 ± 0.02 μg kg(-1)).

  8. A solid phase extraction procedure for the determination of Cd(II) and Pb(II) ions in food and water samples by flame atomic absorption spectrometry.

    PubMed

    Daşbaşı, Teslima; Saçmacı, Şerife; Ülgen, Ahmet; Kartal, Şenol

    2015-05-01

    A relatively rapid, accurate and precise solid phase extraction method is presented for the determination of cadmium(II) and lead(II) in various food and water samples. Quantitation is carried out by flame atomic absorption spectrometry (FAAS). The method is based on the retention of the trace metal ions on Dowex Marathon C, a strong acid cation exchange resin. Some important parameters affecting the analytical performance of the method such as pH, flow rate and volume of the sample solution; type, concentration, volume, flow rate of the eluent; and matrix effects on the retention of the metal ions were investigated. Common coexisting ions did not interfere on the separation and determination of the analytes. The detection limits (3 σb) for Cd(II) and Pb(II) were found as 0.13 and 0.18 μg L(-1), respectively, while the limit of quantification values (10 σb) were computed as 0.43 and 0.60 μg L(-1) for the same sequence of the analytes. The precision (as relative standard deviation was lower than 4% at 5 μg L(-1) Cd(II) and 10 μg L(-1) Pb(II) levels, and the preconcentration factor was found to be 250. The accuracy of the proposed procedure was verified by analysing the certified reference materials, SPS-WW2 Batch 108 wastewater level 2 and INCT-TL-1 tea leaves, with the satisfactory results. In addition, for the accuracy of the method the recovery studies (⩾ 95%) were carried out. The method was applied to the determination of the analytes in the various natural waters (lake water, tap water, waste water with boric acid, waste water with H2SO4) and food samples (pomegranate flower, organic pear, radish leaf, lamb meat, etc.), and good results were obtained. While the food samples almost do not contain cadmium, they have included lead at low levels of 0.13-1.12 μg g(-1).

  9. Determination of Chromium(III), Chromium(VI), and Chromium(III) acetylacetonate in water by ion-exchange disk extraction/metal furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Kamakura, Nao; Inui, Tetsuo; Kitano, Masaru; Nakamura, Toshihiro

    A new method for the separate determination of Chromium(III) (Cr(III)), Chromium(VI) (Cr(VI)), and Cr(III) acetylacetonate (Cr(acac)3) in water was developed using a cation-exchange extraction disk (CED) and an anion-exchange extraction disk (AED) combined with metal furnace atomic absorption spectrometry (MFAAS). A 100-mL water sample was adjusted to pH 5.6 and passed through the CED placed on the AED. Cr(acac)3 and Cr(III) were adsorbed on the CED, and Cr(VI) was adsorbed on the AED. The adsorbed Cr(acac)3 was eluted with 50 mL of carbon tetrachloride, followed by the elution of Cr(III) with 50 mL of 3 mol L- 1 nitric acid. Cr(VI) was eluted with 50 mL of 3 mol L- 1 nitric acid. The chemical species of Cr eluted from the CED with carbon tetrachloride was identified as Cr(acac)3 using infrared spectroscopy. The eluate of Cr(acac)3 was diluted to 100 mL with carbon tetrachloride, and those of Cr(III) and Cr(VI) were diluted to 100 mL with deionized water. All of the solutions were subsequently analyzed by MFAAS. The calibration curve for the Cr(acac)3 aqueous solutions exhibited good linearity in the range of 0.1 to 1 ng. The detection limit of Cr, which corresponded to three times the standard deviation (n = 10) of the blank values, was 20 pg. The recovery test for Cr(III), Cr(VI), and Cr(acac)3 exhibited desirable results (96.0%-107%) when 5 μg of each species (50 μg L- 1) was added to 100 mL water samples (i.e., tap water, rainwater, and bottled drinking water). In a humic acid solution, Cr(acac)3 was quantitatively recovered (103%), but Cr(III) and Cr(VI) exhibited poor recoveries (i.e., 84.8% and 78.4%, respectively).

  10. Lead determination at ng/mL level by flame atomic absorption spectrometry using a tantalum coated slotted quartz tube atom trap.

    PubMed

    Demirtaş, İlknur; Bakırdere, Sezgin; Ataman, O Yavuz

    2015-06-01

    Flame atomic absorption spectrometry (FAAS) still keeps its importance despite the relatively low sensitivity; because it is a simple and economical technique for determination of metals. In recent years, atom traps have been developed to increase the sensitivity of FAAS. Although the detection limit of FAAS is only at the level of µg/mL, with the use of atom traps it can reach to ng/mL. Slotted quartz tube (SQT) is one of the atom traps used to improve sensitivity. In atom trapping mode of SQT, analyte is trapped on-line in SQT for few minutes using ordinary sample aspiration, followed by the introduction of a small volume of organic solvent to effect the revolatilization and atomization of analyte species resulting in a transient signal. This system is economical, commercially available and easy to use. In this study, a sensitive analytical method was developed for the determination of lead with the help of SQT atom trapping flame atomization (SQT-AT-FAAS). 574 Fold sensitivity enhancement was obtained at a sample suction rate of 3.9 mL/min for 5.0 min trapping period with respect to FAAS. Organic solvent was selected as 40 µL of methyl isobutyl ketone (MIBK). To obtain a further sensitivity enhancement inner surface of SQT was coated with several transition metals. The best sensitivity enhancement, 1650 fold enhancement, was obtained by the Ta-coated SQT-AT-FAAS. In addition, chemical nature of Pb species trapped on quartz and Ta surface, and the chemical nature of Ta on quartz surface were investigated by X-ray photoelectron spectroscopy (XPS) and Raman Spectroscopy. Raman spectrometric results indicate that tantalum is coated on SQT surface in the form of Ta2O5. XPS studies revealed that the oxidation state of Pb in species trapped on both bare and Ta coated SQT surfaces is +2. For the accuracy check, the analyses of standard reference material were performed by use of SCP SCIENCE EnviroMAT Low (EU-L-2) and results for Pb were to be in good agreement with

  11. Metallomics approach to trace element analysis in ustilago maydis using cellular fractionation, atomic absorption spectrometry, and size exclusion chromatography with ICP-MS detection.

    PubMed

    Muñoz, Alma Hortensia Serafin; Kubachka, Kevin; Wrobel, Kazimierz; Corona, Felix Gutierrez; Yathavakilla, Santha K V; Caruso, Joseph A; Wrobel, Katarzyna

    2005-06-29

    Huitlacoche is the ethnic name of the young fruiting bodies of Ustilago maydis, a common parasite of maize. In Mexico and other Latin American countries, this fungus has been traditionally appreciated as a local delicacy. In this work a metallomics approach was used with the determination of eight elements in huitlacoche by electrothermal atomic absorption spectrometry as one facet of this approach. The results obtained indicated relatively lower concentrations of commonly analyzed metals, as referred to the data reported for other mushroom types. This effect was ascribed to different accessibilities of elements, depending on fungus substrate (lower from plant than from soil). Subcellular fractionation was accomplished by centrifugation of cell homogenates suspended in Tris-HCl buffer. Recoveries of the fractionation procedure were in the range of 71-103%. For six elements (Cr, Cu, Fe, Mn, Ni, and Pb), the mean relative contributions in cytosol, cell walls, and mixed membrane fraction were 50.7, 48.2, and 1.1% respectively. To attain the molecular weight distribution of compounds containing target elements as an additional aspect of the metallomics approach, the fungus extract (1% sodium dodecyl sulfate in Tris-HCl, 30 mmol L(-)(1), pH 7.0) was analyzed by size exclusion chromatography with UV and ICP-MS detection. With spectrophotometric detection (280 nm), the elution of high molecular weight compounds was observed in the form of one peak (MW > 10 kDa), and several lower peaks appeared at higher retention times (MW < 10 kDa). On ICP-MS chromatograms, a coelution of (59)Co, (63)Cu, (57)Fe, (202)Hg, (60)Ni, and (80)Se with the first peak on the UV chromatogram was clearly observed, indicating that a fraction of each element incorporated with high molecular weight compounds (12.7, 19.8, 33.7, 100, 19.4, and 45.8%, respectively, based on the peak area measurements). From a comparison of (80)Se and (33)S chromatograms (for sulfur analysis, the extract was obtained in

  12. [Study on Content Determination of Lead and Arsenic in Four Traditional Tibetan Medicine Prescription Preparations by Wet Digestion Flow Injection-Hydride Generation-Atomic Absorption Spectrometry].

    PubMed

    Zheng, Zhi-yuan; Du, Yu-zhi; Zhang, Ming; Yu, Ming-jie; Li, Cen; Yang, Hong-xia; Zhao, Jing; Xia, Zheng-hua; Wei, Li-xin

    2015-04-01

    Four common traditional tibetan medicine prescription preparations "Anzhijinghuasan, Dangzuo, Renqingchangjue and Rannasangpei" in tibetan areas were selected as study objects in the present study. The purpose was to try to establish a kind of wet digestion and flow injection-hydride generation-atomic absorption spectrometry (FI-HAAS) associated analysis method for the content determinations of lead and arsenic in traditional tibetan medicine under optimized digestion and measurement conditions and determine their contents accurately. Under these optimum operating conditions, experimental results were as follows. The detection limits for lead and arsenic were 0.067 and 0.012 µg · mL(-1) respectively. The quantification limits for lead and arsenic were 0.22 and 0.041 µg · mL(-1) respectively. The linear ranges for lead and arsenic were 25-1,600 ng · mL(-1) (r = 0.9995) and 12.5-800 ng · mL(-1) (r = 0.9994) respectively. The degrees of precision(RSD) for lead and arsenic were 2.0% and 3.2% respectively. The recovery rates for lead and arsenic were 98.00%-99.98% and 96.67%-99.87% respectively. The content determination results of lead and arsenic in four traditional tibetan medicine prescription preparations were as fol- lows. The contents of lead and arsenic in Anzhijinghuasan are 0.63-0.67 µg · g(-1) and 0.32-0.33 µg · g(-1) in Anzhijinghua- san, 42.92-43.36 µg · g(-1) and 24.67-25.87 µg · g(-1) in Dangzuo, 1,611. 39-1,631.36 µg · g(-1) and 926.76-956.52 µg- g(-1) in Renqing Changjue, and 1,102.28-1,119.127 µg-g(-1) and 509.96-516.87 µg · g(-1) in Rannasangpei, respectively. This study established a method for content determination of lead and arsenic in traditional tibetan medicine, and determined the content levels of lead and arsenic in four tibetan medicine-prescription preparations accurately. In addition, these results also provide the basis for the safe and effective use of those medicines in clinic.

  13. Investigation of an alternating current plasma as an element selective atomic emission detector for high-resolution capillary gas chromatography and as a source for atomic absorption and atomic emission spectrometry

    NASA Astrophysics Data System (ADS)

    Ombaba, Jackson M.

    This thesis deals with the construction and evaluation of an alternating current plasma (ACP) as an element-selective detector for high resolution capillary gas chromatography (GC) and as an excitation source for atomic absorption spectrometry (AAS) and atomic emission spectrometry (AES). The plasma, constrained in a quartz discharge tube at atmospheric pressure, is generated between two copper electrodes and utilizes helium as the plasma supporting gas. The alternating current plasma power source consists of a step-up transformer with a secondary output voltage of 14,000 V at a current of 23 mA. The device exhibits a stable signal because the plasma is self-seeding and reignites itself every half cycle. A tesla coil is not required to commence generation of the plasma if the ac voltage applied is greater than the breakdown voltage of the plasma-supporting gas. The chromatographic applications studied included the following: (1) the separation and selective detection of the organotin species, tributyltin chloride (TBT) and tetrabutyltin (TEBT), in environmental matrices including mussels (Mvutilus edullus) and sediment from Boston Harbor, industrial waste water and industrial sludge, and (2) the detection of methylcyclopentadienyl manganesetricarbonyl (MMT) and similar compounds used as gasoline additives. An ultrasonic nebulizer (common room humidifier) was utilized as a sample introduction device for aqueous solutions when the ACP was employed as an atomization source for atomic absorption spectrometry and as an excitation source for atomic emission spectrometry. Plasma diagnostic parameters studied include spatial electron number density across the discharge tube, electronic, excitation and ionization temperatures. Interference studies both in absorption and emission modes were also considered. Figures of merits of selected elements both in absorption and emission modes are reported. The evaluation of a computer-aided optimization program, Drylab GC, using

  14. Determination of Fe(II) and Fe(III) in small samples by microbore ion chromatography and photometric, atomic absorption spectrometry and total-reflection X-ray fluorescence detection

    NASA Astrophysics Data System (ADS)

    Sinner, T.; Hoffmann, P.; Ortner, H. M.

    1993-02-01

    Iron(II) and iron(III) are determined after separation on an ion Chromatographie column by various detection systems. "On-line" detection was achieved by the use of a photometer with a flow cell of 0.8 μl; for "off-line" detection, graphite furnace atomic absorption spectrometry or total-reflection X-ray fluorescence were used. The applicability of the methods is shown for standard solutions and atmospheric samples. As a typical result, 50 μg/l of iron can be determined in a 10 μl sample with a nucrobore ion chromatograph-photometer and atomic absorption system and 40 μg/l of iron in a microbore ion chromatograph-total-reflection X-ray fluorescence combination.

  15. Working towards accreditation by the International Standards Organization 15189 Standard: how to validate an in-house developed method an example of lead determination in whole blood by electrothermal atomic absorption spectrometry.

    PubMed

    Garcia Hejl, Carine; Ramirez, Jose Manuel; Vest, Philippe; Chianea, Denis; Renard, Christophe

    2014-09-01

    Laboratories working towards accreditation by the International Standards Organization (ISO) 15189 standard are required to demonstrate the validity of their analytical methods. The different guidelines set by various accreditation organizations make it difficult to provide objective evidence that an in-house method is fit for the intended purpose. Besides, the required performance characteristics tests and acceptance criteria are not always detailed. The laboratory must choose the most suitable validation protocol and set the acceptance criteria. Therefore, we propose a validation protocol to evaluate the performance of an in-house method. As an example, we validated the process for the detection and quantification of lead in whole blood by electrothermal absorption spectrometry. The fundamental parameters tested were, selectivity, calibration model, precision, accuracy (and uncertainty of measurement), contamination, stability of the sample, reference interval, and analytical interference. We have developed a protocol that has been applied successfully to quantify lead in whole blood by electrothermal atomic absorption spectrometry (ETAAS). In particular, our method is selective, linear, accurate, and precise, making it suitable for use in routine diagnostics.

  16. Trace level determination of cadmium in wine by on-line preconcentration in a 5-Br-PADAP functionalized wool-packed microcolumn coupled to flame atomic absorption spectrometry.

    PubMed

    Monasterio, Romina P; Wuilloud, Rodolfo G

    2009-10-15

    An on-line retention and preconcentration system based on a sheep wool-packed microcolumn combined with flame atomic absorption spectrometry is proposed for trace level determination of Cd in wine. A chelating reagent 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol was immobilized onto the wool before retention of the analyte. Several factors influencing the preconcentration efficiency of Cd and his subsequent determination, such as pH, eluent type, sample and eluent flow rates, interfering effects, were studied. A preconcentration factor of 39 was obtained with only 20 mL of sample. The relative standard deviation for five determinations of 1 microg L(-1) Cd was 3.4%. The calibration graph was linear with a correlation coefficient of 0.998 at levels near the detection limit and up to at least 25 microg L(-1). The limit of detection was 37 ng L(-1). The accuracy of the proposed methodology was tested by comparison of the results with those obtained by electrothermal atomic absorption spectrometry analysis along with a recovery study. Finally, the method was employed for evaluating Cd levels in different wines including, blank, rose, and red.

  17. High-resolution continuum source electrothermal absorption spectrometry of AlBr and CaBr for the determination of bromine

    NASA Astrophysics Data System (ADS)

    Huang, Mao Dong; Becker-Ross, Helmut; Florek, Stefan; Heitmann, Uwe; Okruss, Michael

    2008-05-01

    Molecular absorption spectra of AlBr and CaBr, produced in a graphite furnace, were investigated using a high-resolution echelle spectrometer equipped with a xenon short-arc lamp as continuum source. The analytical usability of the spectra for the determination of bromine was studied. To this end, the molecular absorptions of AlBr at 278.914 nm and CaBr at 625.315 nm were evaluated. Apart from strong absorption bands of CaF around 625.3 nm, which disturb the use of CaBr, no spectral interferences were observed for both AlBr and CaBr. Regarding chemical interference with matrix substances, the molecular absorption of AlBr and CaBr is influenced in a different way. While the sensitivity of the CaBr absorption is susceptible to chloride, aluminum, potassium and sodium ions, there is no significant effect on the AlBr absorption. In contrast, the inorganic acids (nitric, phosphoric, and sulfuric) have an influence on AlBr, but not on the CaBr molecular absorption. Therefore, the two methods complement each other and each has its own application area. Regarding real samples, a salt sample from the death sea and an organic pharmaceutical were evaluated. The results were in good agreement with those derived from two independent methods and with an existing reference value. Relative standard deviations were found in the range of 5%. The limit of detection for bromine was about 2 ng for both AlBr and CaBr molecular absorption; the dynamic range was linear at least up to 250 ng Br.

  18. Column chromatographic pre-concentration of iron(III) in alloys and biological samples with 1-nitroso-2-naphthol-3,6-disulphonate and benzyldimethyltetradecylammonium-perchlorate adsorbent supported on naphthalene using atomic absorption spectrometry.

    PubMed

    Miura, J; Arima, S; Satake, M

    1990-09-01

    The solid ion-pair material produced from the reaction between benzyldimethyltetradecylammonium chloride (BDTA) and sodium perchlorate on naphthalene provides the basis for a simple, rapid and selective technique for pre-concentrating iron from up to 500 ml of aqueous solution. Iron reacts with disodium 1-nitroso-2-naphthol-3,6-disulphonate (Nitroso-R salt) to form a water-soluble coloured chelate anion. The iron chelate anion forms a water-insoluble, stable iron-Nitroso-R-BDTA complex on naphthalene packed in a column. Trace amounts of iron are quantitatively retained on naphthalene in the pH range 3.5-7.5 and at a flow-rate of 1-2 ml min-1. The solid mass is dissolved out from the column with 5 ml of N,N-dimethylformamide and iron is determined by means of an atomic absorption spectrometer at 248 nm. The calibration graph is linear for concentrations of iron over the range of 0.5-20 micrograms in 5 ml of final solution. The standard deviation and relative standard deviation were calculated. The detection limit of the method was 0.0196 micrograms ml-1 of iron. The sensitivity for 1% absorption was 0.072 microgram ml-1 (0.165 microgram ml-1 by direct atomic absorption spectrometry of aqueous solution). The proposed method was applied to the determination of iron in standard alloys and biological samples.

  19. A green and efficient procedure for the preconcentration and determination of cadmium, nickel and zinc from freshwater, hemodialysis solutions and tuna fish samples by cloud point extraction and flame atomic absorption spectrometry.

    PubMed

    Galbeiro, Rafaela; Garcia, Samara; Gaubeur, Ivanise

    2014-04-01

    Cloud point extraction (CPE) was used to simultaneously preconcentrate trace-level cadmium, nickel and zinc for determination by flame atomic absorption spectrometry (FAAS). 1-(2-Pyridilazo)-2-naphthol (PAN) was used as a complexing agent, and the metal complexes were extracted from the aqueous phase by the surfactant Triton X-114 ((1,1,3,3-tetramethylbutyl)phenyl-polyethylene glycol). Under optimized complexation and extraction conditions, the limits of detection were 0.37μgL(-1) (Cd), 2.6μgL(-1) (Ni) and 2.3μgL(-1) (Zn). This extraction was quantitative with a preconcentration factor of 30 and enrichment factor estimated to be 42, 40 and 43, respectively. The method was applied to different complex samples, and the accuracy was evaluated by analyzing a water standard reference material (NIST SRM 1643e), yielding results in agreement with the certified values.

  20. Freon (CHF3)-assisted atomization for the determination of titanium using ultrasonic slurry sampling-graphite furnace atomic absorption spectrometry (USS-GFAAS): a simple and advantageous method for solid samples.

    PubMed

    Asfaw, Alemayehu; Wibetoe, Grethe

    2004-06-01

    A simple and advantageous method for the determination of titanium using graphite furnace atomic absorption spectrometry with slurry sampling has been developed. Titanium is one of the refractory elements that form thermally stable carbides in the graphite tube, which leads to severe memory effects. Trifluoromethane (Freon-23) was applied in the purge gas during the atomization step or alternatively just prior to the atomization to successfully eliminate the problems of carbide formation and increase the lifetime of the furnace tube which could be used for more than 600 heating cycles. A flow rate of 40 mL min(-1) (5% of Freon in argon) was used to obtain symmetrical peaks with no tailing. However, when the gas flow rate was too high (250 mL min(-1)) the peak-tailing and memory effects reappeared. Ti was determined in various materials covering a wide range of concentrations, from 2.8 microg g(-1) to 12% (m/m) Ti. The accuracy of the method was confirmed by analyzing certified reference materials (CRMs) or by comparing the results with those obtained using inductively coupled plasma-atomic emission spectrometry (ICP-AES) after decomposition of the samples. The materials analyzed were soil, plant, human hair, coal, urban particulate matters, toothpaste, and powdered paint.

  1. Combustion diagnostics by laser spectrometry

    NASA Astrophysics Data System (ADS)

    Kitagawa, Kuniyuki; Morita, Shigeaki; Kodama, Kenji; Matsumoto, Kozo

    2009-03-01

    We have developed three different types of visualization methods for energy conversion systems by means of laser spectrometry. (1) Laser-induced fluorescence (LIF) spectroscopy and (2) laser ionization mass spectrometry (LIMS) have been applied to visualization of chemical species in combustion fields of flames. (3) Near-infrared laser absorption spectroscopy has been used for visualization of water in a polymer electrolyte fuel cell (PEFC). Complex physicochemical processes in the energy conversion systems have been revealed by laser spectrometry.

  2. Determination of fluorine in tea using high-resolution molecular absorption spectrometry with electrothermal vaporization of the calcium mono-fluoride CaF.

    PubMed

    Morés, Silvane; Monteiro, Gustavo C; Santos, Flaviane da Silva; Carasek, Eduardo; Welz, Bernhard

    2011-10-15

    High-resolution continuum source molecular absorption of the calcium mono-fluoride molecule CaF in a graphite furnace has been used to determine fluorine in tea after acid digestion, alkaline solubilization and preparation of a conventional aqueous infusion. The strongest absorption 'line' of the CaF molecule is at 606.440 nm, which is part of the rotational fine structure of the X(2)Σ(+)-A(2)Π electronic transition; it has a bond dissociation energy of 529 kJ mol(-1), which is comparable with other molecules used for fluorine determination. One advantage of using Ca as the molecule-forming reagent is that spectral interferences are extremely unlikely in the spectral range of its strongest absorption. Another advantage is that Ca acts both as molecule forming reagent and chemical modifier, so that no other reagent has to be added, making the method very simple. The only disadvantage is that Ca has a somewhat negative influence on the graphite tube lifetime. The limit of detection was found to be 0.16 mg L(-1) F, corresponding to 1.6 ng F absolute, and the calibration curve was linear in the range between 0.5 and 25 mg L(-1) with a correlation coefficient of R=0.9994. The results obtained for a certified tea reference material were in agreement with the certified value on a 95% confidence level. There was also no difference between the results obtained after an acid digestion and an alkaline solubilization for 10 tea samples, based on a paired t-test. The values found in the 10 samples ranged between 42 μg g(-1) and 87 μg g(-1) F; the tea infusions contained between 21 μg g(-1) and 56 μg g(-1) F, with an extraction rate between 48% and 74%.

  3. Molecular characterization and profile identifications of vanadyl compounds in heavy crude petroleums by liquid chromatography/graphite furnace atomic absorption spectrometry

    SciTech Connect

    Fish, R.H.; Komlenic, J.J.

    1984-03-01

    Four heavy crude petroleums, Boscan, Cerro Negro, Wilmington, and Prudhoe Bay, have been examined by high-performance liquid chromatography in combination with graphite furnace atomic absorption detection (HPLC/GFAA) to provide both a vanadium fingerprint and a molecular weight categorization of the vanadyl porphyrin and non-porphyrin compounds present. We have also attempted to speciate the vanadyl porphyrin and non-porphyrin compounds in these heavy crude oils by comparison of their size exclusion and polar aminocyano separated vanadium histograms to authentic compounds. 35 references, 8 figures, 3 tables.

  4. Correction of structured molecular background by means of high-resolution continuum source electrothermal atomic absorption spectrometry--determination of antimony in sediment reference materials using direct solid sampling.

    PubMed

    Araujo, Rennan G O; Welz, Bernhard; Vignola, Fabiola; Becker-Ross, Helmut

    2009-12-15

    A simple, fast and accurate procedure is proposed for the determination of antimony in certified sediment reference materials using direct solid sampling high-resolution continuum source electrothermal atomic absorption spectrometry and iridium as a permanent modifier. The less sensitive resonance line at 231.147 nm has been used in order to allow the introduction of larger sample mass. Six certified reference materials, one river, one estuarine and four marine sediments have been analyzed. The use of iridium as a permanent modifier caused an increase of 30% in sensitivity and stabilized antimony in the sediment to a pyrolysis temperature of 1100 degrees C. Significant background absorption with pronounced rotational fine structure was observed at the optimum atomization temperature of 2100 degrees C, which coincided with the analyte atomic absorption in time. This background was found to be due to the electron excitation spectra of mostly the SiO and in part the PO molecules, and could be eliminated by applying a least-squares background correction algorithm. A characteristic mass of 28 pg Sb was obtained, and the limit of detection (3sigma, n=10) was 0.02 microg g(-1), calculated for 0.2 mg of sample. The results obtained for six certified reference materials with concentrations between 0.40 and 11.6+/-2.6 microg g(-1) Sb were in agreement with the certified values according to a Student's t-test for a 95% confidence level, using aqueous standards for calibration. The precision, expressed as relative standard deviation, ranged between 7% and 17% (n=5).

  5. Determination of essential elements in beverages, herbal infusions and dietary supplements using a new straightforward sequential approach based on flame atomic absorption spectrometry.

    PubMed

    Gómez-Nieto, Beatriz; Gismera, Mª Jesús; Sevilla, Mª Teresa; Procopio, Jesús R

    2017-03-15

    A simple method based on FAAS was developed for the sequential multi-element determination of Cu, Zn, Mn, Mg and Si in beverages and food supplements with successful results. The main absorption lines for Cu, Zn and Si and secondary lines for Mn and Mg were selected to carry out the measurements. The sample introduction was performed using a flow injection system. Using the choice of the absorption line wings, the upper limit of the linear range increased up to 110mgL(-1) for Mg, 200mgL(-1) for Si and 13mgL(-1) for Zn. The determination of the five elements was carried out, in triplicate, without the need of additional sample dilutions and/or re-measurements, using less than 3.5mL of sample to perform the complete analysis. The LODs were 0.008mgL(-1) for Cu, 0.017mgL(-1) for Zn, 0.011mgL(-1) for Mn, 0.16mgL(-1) for Si and 0.11mgL(-1) for Mg.

  6. Determination of sulfur in human hair using high resolution continuum source graphite furnace molecular absorption spectrometry and its correlation with total protein and albumin

    NASA Astrophysics Data System (ADS)

    Ozbek, Nil; Baysal, Asli

    2017-04-01

    Human hair is a valuable contributor for biological monitoring. It is an information storage point to assess the effects of environmental, nutritional or occupational sources on the body. Human proteins, amino acids or other compounds are among the key components to find the sources of different effects or disorders in the human body. Sulfur is a significant one of these compounds, and it has great affinity to some metals and compounds. This property of the sulfur affects the human health positively or negatively. In this manuscript, sulfur was determined in hair samples of autistic and age-match control group children via molecular absorption of CS using a high-resolution continuum source graphite furnace atomic absorption spectrometer. For this purpose, hair samples were appropriately washed and dried at 75 °C. Then samples were dissolved in microwave digestion using HNO3 for sulfur determination. Extraction was performed with HCl hydrolysation by incubation for 24 h at 110 °C for total protein and albumin determination. The validity of the method for the sulfur determination was tested using hair standard reference materials. The results were in the uncertainty limits of the certified values at 95% confidence level. Finally correlation of sulfur levels of autistic children's hair with their total protein and albumin levels were done.

  7. Absolute number densities of helium metastable atoms determined by atomic absorption spectroscopy in helium plasma-based discharges used as ambient desorption/ionization sources for mass spectrometry

    NASA Astrophysics Data System (ADS)

    Reininger, Charlotte; Woodfield, Kellie; Keelor, Joel D.; Kaylor, Adam; Fernández, Facundo M.; Farnsworth, Paul B.

    2014-10-01

    The absolute number densities of helium atoms in the 2s 3S1 metastable state were determined in four plasma-based ambient desorption/ionization sources by atomic absorption spectroscopy. The plasmas included a high-frequency dielectric barrier discharge (HF-DBD), a low temperature plasma (LTP), and two atmospheric-pressure glow discharges, one with AC excitation and the other with DC excitation. Peak densities in the luminous plumes downstream from the discharge capillaries of the HF-DBD and the LTP were 1.39 × 1012 cm- 3 and 0.011 × 1012 cm- 3, respectively. Neither glow discharge produced a visible afterglow, and no metastable atoms were detected downstream from the capillary exits. However, densities of 0.58 × 1012 cm- 3 and 0.97 × 1012 cm- 3 were measured in the interelectrode regions of the AC and DC glow discharges, respectively. Time-resolved measurements of metastable atom densities revealed significant random variations in the timing of pulsed absorption signals with respect to the voltage waveforms applied to the discharges.

  8. Determination of tin, vanadium, iron, and molybdenum in various matrices by atomic absorption spectrometry using a simultaneous liquid-liquid extraction procedure.

    PubMed

    Sánchez-Viñas, M; Bagur, G M; Gázquez, D; Camino, M; Romero, R

    1999-01-01

    An atomic-absorption spectrometric method is described for the determination of tin, vanadium, iron, and molybdenum in two certified reference materials, food samples, and petroleum crude. After treatment with acids, these elements are separated from matrix elements by simultaneous solvent extraction of 5,5'-methylenedisalicylohydroxamic acid complexes from HCl/NaClO4 solution into an isobutyl methyl ketone/tributyl phosphate solution. The detection limits range from 0.018 to 0.19 microg/mL (n = 3), and the relative standard deviations do not exceed 2.0% at levels of 0.5, 0.6, 2.0, and 7.0 microg/mL of Fe, Mo, V, and Sn, respectively. The method is selective and suffers only from interference by Zr(IV), Ti(IV), Th(IV), W(VI), PO4(3-), and F-.

  9. Solid-phase chelate extractive preconcentration of heavy metal ions prior to their ultratrace determination by microsample injection system coupled flame atomic absorption spectrometry.

    PubMed

    Sarı, Serdar; Kartal, Aslıhan Arslan; Elçi, Aydan; Akdoğan, Abdullah; Höl, Aysen; Siyal, Ali Nawaz; Elçi, Latif

    2013-01-01

    Chromosorb-105 resin/1-(2-pyridylazo)-2-naphthol (PAN) system was developed for solid phase chelate extractive preconcentration of heavy metal ions. The metal ions on Chromosorb-105 resin column were eluted with 3.0 mL of 2.0 mol L-1 HNO3 and determined by microsample injection system coupled flame atomic spectrometry (MIS-FAAS) using 75.0 µL of sample solution for single element determination. The influence of pH, resin amount, reagent amount, flow rate and volume of eluent and sample solution was optimized. The quantitative recoveries (≥95%) of Fe(III), Zn(II), Cu(II) and Pb(II) ions were achieved at pH 9; resin amount, 700 mg; reagent amount, 6.0 µmol; flow rate of eluent and sample solution, 1.0 mL min-1 and 5.0 mL min-1, respectively. The limit of detection and limit of quantification of understudied analytes were found to be 0.17-1.74 µg L-1 and 0.40-2.98 µg L-1, respectively with preconcentration factor of 150-300. The proposed method was validated by analysis of waste water (BCR-715) as a certified reference material. The method was applied successfully for ultratrace determination of studied metal ions in tap water and hot spring water samples.

  10. Poly(etheretherketone)-turnings a novel sorbent material for lead determination by flow injection flame atomic absorption spectrometry and factorial design optimization.

    PubMed

    Anthemidis, Aristidis N; Adam, Ibrahim S I; Zachariadis, George A

    2010-05-15

    A novel hydrophobic sorbent material for on-line column preconcentration and separation systems coupled with atomic spectrometry was developed. Poly(etheretherketone) (PEEK) in the form of turnings was used as packing material and evaluated for trace lead determination in environmental samples. Sample and ammonium diethyl-dithiophosphate (DDPA) reagent were mixed on-line and the Pb(II)-DDPA complex was retained effectively on PEEK-turnings. Isobutyl methyl ketone (IBMK) was adopted for efficient analyte complex elution and subsequently transportation into the nebulizer-burner system for atomization. The developed sorbent material has shown, excellent chemical and mechanical resistance, fast adsorption kinetics permitting the use of high sample flow rates without significant loss of retention efficiency. For 120s sample preconcentration time the sampling frequency was 20h(-1), the enhancement factor was 110, the detection limit (3s) was c(L)=0.32microgL(-1), and the relative standard deviation (RSD) was s(R)=2.2%, at the 50.0microgL(-1) Pb(II) level. The accuracy of the developed method was evaluated by analyzing certified reference materials.

  11. New anion-exchange solid-phase extraction support used for preconcentration and determination of lead in water samples by flame atomic absorption spectrometry.

    PubMed

    Panahi, Homayon Ahmad; Feizbakhsh, Ali Reza; Tafazoli, Zahra; Moniri, Elham; Nezhati, Mahshid Nikpour; Moghaddam, Hamid Hashemi; Kelahrodi, Somayeh Rangbar

    2010-01-01

    A new chelating resin was prepared by coupling Amberlite XAD-2 with Brilliant Green through an azo spacer. The resulting resin has been characterized by FTIR spectrometry, elemental analysis, and thermogravimetric analysis and studied for the preconcentration and determination of trace Pb(II) ions from solution samples. The anionic complex of Pb(II) and iodide was retained on the resin by the formation of an ion associate with Brilliant Green on Amberlite XAD-2 in weak acidic medium. The optimum pH value for sorption of the metal ion was 5.5. The sorption capacity of the functionalized resin is 53.8 mg/g. The chelating resin can be reused for 20 cycles of sorption-desorption without any significant change in sorption capacity. A recovery of 103% was obtained for the metal ion with 0.1 M EDTA as the eluting agent. Scatchard analysis revealed that the homogeneous binding sites were formed in the polymers. The resin was subjected to evaluation through batch binding and column chromatography of Pb(II). The equilibrium adsorption data of Pb(II) on modified resin were analyzed by Langmuir, Freundlich, and Temkin models. Based on equilibrium adsorption data, the Langmuir, Freundlich, and Temkin constants were determined to be 0.192, 13.189, and 3.418 at pH 5.5 and 25 degrees C. The method was applied for lead ion determination in tap water samples.

  12. Use of carbon nanotubes and electrothermal atomic absorption spectrometry for the speciation of very low amounts of arsenic and antimony in waters.

    PubMed

    López-García, Ignacio; Rivas, Ricardo E; Hernández-Córdoba, Manuel

    2011-10-30

    A procedure for the determination of inorganic arsenic (III, V) and antimony (III, V) in water samples by using a miniaturized solid-phase extraction with carbon nanotubes followed by electrothermal atomic absorption measurement is proposed. The trivalent species are first complexed with ammonium pyrrolidinedithiocarbamate, next retained in a mini-column containing nanotubes and then eluted by means of a plug of an ammonia solution. The atomizer is impregnated with a tungsten salt which acts as an effective chemical modifier during the heating cycle. Total inorganic arsenic and antimony are determined after the reduction of the pentavalent forms with an ammonium iodide solution. Pentavalent arsenic and antimony are calculated by difference. When using 50 mL sample solutions, the limits of detection are 0.02 and 0.05 μg L(-1) for As and Sb, respectively, and the enrichment factor is 250. The relative standard deviations calculated for five determinations at the 1 μg L(-1) level are below 4%.

  13. Preconcentration and determination of boron in milk, infant formula, and honey samples by solid phase extraction-electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    López-García, I.; Viñas, P.; Romero-Romero, R.; Hernández-Córdoba, M.

    2009-02-01

    This work presents alternative procedures for the electrothermal atomic absorption spectrometric determination of boron in milk, infant formulas, and honey samples. Honey samples (10% m/v) were diluted in a medium containing 1% v/v HNO 3 and 50% v/v H 2O 2 and introduced in the atomizer. A mixture of 20 µg Pd and 0.5 µg Mg was used for chemical modification. Calibration was carried out using aqueous solutions prepared in the same medium, in the presence of 10% m/v sucrose. The detection limit was 2 µg g - 1 , equivalent to three times the standard error of the estimate ( sy/ x) of the regression line. For both infant formulas and milk samples, due to their very low boron content, we used a procedure based on preconcentration by solid phase extraction (Amberlite IRA 743), followed by elution with 2 mol L - 1 hydrochloric acid. Detection limits were 0.03 µg g - 1 for 4% m/v honey, 0.04 µg g - 1 for 5% m/v infant formula and 0.08 µg mL - 1 for 15% v/v cow milk. We confirmed the accuracy of the procedure by comparing the obtained results with those found via a comparable independent procedure, as well by the analysis of four certified reference materials.

  14. Determination of traces of rubidium in high purity cesium chloride by electrothermal atomic absorption spectrometry (ETAAS) using boric acid as a modifier.

    PubMed

    Dash, K; Thangavel, S; Chaurasia, S C; Arunachalam, J

    2007-02-12

    The use of boric acid as a modifier for the determination of trace amount of rubidium in high purity cesium chloride matrix by electrothermal atomic absorption is described. It was found that the negative influence of the chloride matrix could not be eliminated using stabilized temperature platform (STPF) alone. Due to the high dissociation energy (D(0)=427 kJ mol(-1)) of rubidium chloride, it was difficult to dissociate in the gas phase and hence is lost. Elimination of interferences was achieved by the addition of boric acid as a chemical modifier. Diluted cesium chloride samples (5%, m/v) were analyzed applying the standard addition method. The characteristic mass of 24 pg was obtained. The detection limit of the proposed method is around 26 ng g(-1). The developed method was applied to the determination of traces of rubidium in high purity cesium chloride samples. The data obtained by this method were in good agreement with those obtained by other independent method like FAAS.

  15. Comparison of UV absorption and electrospray mass spectrometry for the high-performance liquid chromatographic determination of domoic acid in shellfish and biological samples.

    PubMed

    Lawrence, J F; Lau, B P; Cleroux, C; Lewis, D

    1994-01-21

    Domoic acid, a neurotoxic amino acid produced by the marine diatom Nitchia pungens multiseries, was determined in samples of anchovies, razor clams, mussels, crab, rat serum, urine and feces by HPLC with UV absorption and electrospray (ESI) mass spectrometric (MS) detection. Shellfish samples were extracted with methanol-water followed by clean-up of the extracts with solid-phase extraction cartridges (strong anion or strong cation exchange). An aliquot of the fraction containing the domoic acid was analysed by HPLC. HPLC column size, mobile phase composition and flow-rate were selected so that essentially the same conditions could be used for both HPLC-UV and HPLC-ESI-MS with selected ion monitoring (SIM) determinations. These included the use of acetonitrile-water-formic acid as the mobile phase, at a flow-rate of 0.2 ml/min (split 13:1 for HPLC-ESI-MS-SIM, 10 microliters/min to the mass spectrometer). The results indicated that extracts found positive by the HPLC-UV method could be readily confirmed directly by HPLC-ESI-MS-SIM without additional sample treatment down to levels of 0.1 micrograms/g of domoic acid. This study demonstrates the use of HPLC-ESI-MS-SIM for the routine confirmation of domoic acid in a wide variety of samples.

  16. An accelerator mass spectrometry-enabled microtracer study to evaluate the first-pass effect on the absorption of YH4808.

    PubMed

    Kim, Anhye; Yu, Byung-Yong; Dueker, Stephen R; Shin, Kwang-Hee; Kim, Hwa Suk; Ahn, Hyungmi; Cho, Joo-Youn; Yu, Kyung-Sang; Jang, In-Jin; Lee, Howard

    2017-02-18

    (14) C-labeled YH4808, a novel potassium-competitive acid blocker, was intravenously administered as a microtracer at 80 μg (11.8 kBq or 320 nCi) concomitantly with the non-radiolabeled oral drug at 200 mg to determine the absolute bioavailability and to assess the effect of pharmacogenomics on the oral absorption of YH4808. The absolute bioavailability was low and highly variable (mean, 10.1%; range, 2.3-19.3%), and M3 and M8, active metabolites of YH4808, were formed 22.6- and 38.5-fold higher after oral administration than intravenous administration, respectively. The product of the fraction of an oral YH4808 dose entering the gut wall and the fraction of YH4808 passing on to the portal circulation was larger in subjects carrying the variants of the CHST3, SLC15A1, and SULT1B1 genes. A combined LC+AMS is a useful tool to construct a rich and highly informative PK knowledge core in early clinical drug development at a reasonable cost. This article is protected by copyright. All rights reserved.

  17. Antimony in drinking water, red blood cells, and serum: development of analytical methodology using transversely heated graphite furnace atomization-atomic absorption spectrometry.

    PubMed

    Subramanian, K S; Poon, R; Chu, I; Connor, J W

    1997-05-01

    An atomic absorption spectrometric (AAS) method has been developed for determining microg/L levels of Sb in samples of water and blood. The AAS method is based on the concept of stabilized temperature platform furnace atomization (STPF) realized through the use of a transversely heated graphite atomizer (THGA) furnace, longitudinal Zeeman-effect background correction, and matrix modification with palladium nitrate-magnesium nitrate-nitric acid. The method of standard additions is not mandatory. The detection limit (3 standard deviations of the blank) is 2.6 microg Sb/L for the water, red blood cells (RBCs), and serum samples. Data are presented on the degree of accuracy and precision. The THGA-AAS method is simple, fast, and contamination-free because the entire operation from sampling to AAS measurement is carried out in the same tube. The method has been applied to the determination of Sb in some leachate tap water samples derived from a static copper plumbing system containing Sn/Sb solders, and in small samples (0.5 ml) of RBCs and serum derived from rats given Sb-supplemented drinking water.

  18. Cloud point extraction for determination of lead in blood samples of children, using different ligands prior to analysis by flame atomic absorption spectrometry: a multivariate study.

    PubMed

    Shah, Faheem; Kazi, Tasneem Gul; Afridi, Hassan Imran; Naeemullah; Arain, Muhammad Balal; Baig, Jameel Ahmed

    2011-09-15

    The phase-separation phenomenon of non-ionic surfactants occurring in aqueous solution was used for the extraction of lead (Pb(2+)) from digested blood samples after simultaneous complexation with ammonium pyrrolidinedithiocarbamate (APDC) and diethyldithiocarbamate (DDTC) separately. The complexed analyte was quantitatively extracted with octylphenoxypolyethoxyethanol (Triton X-114). The multivariate strategy was applied to estimate the optimum values of experimental factors. Acidic ethanol was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometer (FAAS). The detection limit value of Pb(2+) for the preconcentration of 10 mL of acid digested blood sample was 1.14 μg L(-1). The accuracy of the proposed methods was assessed by analyzing certified reference material (whole blood). Under the optimized conditions of both CPE methods, 10 mL of Pb(2+) standards (10 μg L(-1)) complexed with APDC and DDTC, permitted the enhancement factors of 56 and 42, respectively. The proposed method was used for determination of Pb(2+) in blood samples of children with kidney disorders and healthy controls.

  19. Utilization of W/Mg(NO 3) 2 modifiers for the direct determination of As and Sb in soils, sewage sludge and sediments by solid sampling electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Török, Peter; Žemberyová, Mária

    2010-04-01

    A simple method has been developed for the determination of arsenic and antimony in environmental samples by solid sampling electrothermal atomic absorption spectrometry, which was validated using certified reference materials of soils (S-VM — Soil Eutric Cambisol; S-MS — Soil Orthic Luvisols; S-SP — Soil Rendzina), sewage sludge (WT-L; WT-M) and sediments (NIES2; GBW07906). The analytical procedure combines solid sampling with utilization of a matrix modifier admixture containing 5 µg of W and 5 µg of Mg. The tungsten in the admixture serves to stabilize the solid matrix during atomisation, which results in dramatically reduced non-specific absorption compared with the conventional palladium modifier. Magnesium was efficient in reducing the accumulation of the matrix residue on the platform. An alternative resonance line of 197.2 nm for arsenic and 206.8 nm for Sb was used in order to eliminate the spectral interferences caused by aluminum compounds, and silicon and iron compounds, respectively. Under optimized experimental conditions, the effective in situ analyte/matrix separation was achieved so that the use of aqueous standards for calibration became possible. With the modifier, a 3 SD detection limit of 0.5 µg g -1 As and 0.1 µg g -1 Sb and 10 SD quantification limit of 1.7 µg g -1As and 0.3 µg g -1 Sb and a characteristic mass of 65 pg As and 53 pg Sb were obtained. For all the matrices under scrutiny, a good agreement with certified values was achieved with RSD values less than 10%.

  20. Use of radiation sources with mercury isotopes for real-time highly sensitive and selective benzene determination in air and natural gas by differential absorption spectrometry with the direct Zeeman effect.

    PubMed

    Revalde, Gita; Sholupov, Sergey; Ganeev, Alexander; Pogarev, Sergey; Ryzhov, Vladimir; Skudra, Atis

    2015-08-05

    A new analytical portable system is proposed for the direct determination of benzene vapor in the ambient air and natural gas, using differential absorption spectrometry with the direct Zeeman effect and innovative radiation sources: capillary mercury lamps with different isotopic compositions ((196)Hg, (198)Hg, (202)Hg, (204)Hg, and natural isotopic mixture). Resonance emission of mercury at a wavelength of 254 nm is used as probing radiation. The differential cross section of benzene absorption in dependence on wavelength is determined by scanning of magnetic field. It is found that the sensitivity of benzene detection is enhanced three times using lamp with the mercury isotope (204)Hg in comparison with lamp, filled with the natural isotopic mixture. It is experimentally demonstrated that, when benzene content is measured at the Occupational Exposure Limit (3.2 mg/m(3) for benzene) level, the interference from SO2, NO2, O3, H2S and toluene can be neglected if concentration of these gases does not exceed corresponding Occupational Exposure Limits. To exclude the mercury effect, filters that absorb mercury and let benzene pass in the gas duct are proposed. Basing on the results of our study, a portable spectrometer is designed with a multipath cell of 960 cm total path length and detection limit 0.5 mg/m(3) at 1 s averaging and 0.1 mg/m(3) at 30 s averaging. The applications of the designed spectrometer to measuring the benzene concentration in the atmospheric air from a moving vehicle and in natural gas are exemplified.

  1. Method development for the control determination of mercury in seafood by solid-sampling thermal decomposition amalgamation atomic absorption spectrometry (TDA AAS).

    PubMed

    Torres, D P; Martins-Teixeira, M B; Silva, E F; Queiroz, H M

    2012-01-01

    A very simple and rapid method for the determination of total mercury in fish samples using the Direct Mercury Analyser DMA-80 was developed. In this system, a previously weighted portion of fresh fish is combusted and the released mercury is selectively trapped in a gold amalgamator. Upon heating, mercury is desorbed from the amalgamator, an atomic absorption measurement is performed and the mercury concentration is calculated. Some experimental parameters have been studied and optimised. In this study the sample mass was about 100.0 mg. The relative standard deviation was lower than 8.0% for all measurements of solid samples. Two calibration curves against aqueous standard solutions were prepared through the low linear range from 2.5 to 20.0 ng of Hg, and the high linear range from 25.0 to 200.0 ng of Hg, for which a correlation coefficient better than 0.997 was achieved, as well as a normal distribution of the residuals. Mercury reference solutions were prepared in 5.0% v/v nitric acid medium. Lyophilised fish tissues were also analysed; however, the additional procedure had no advantage over the direct analysis of the fresh fish, and additionally increased the total analytical process time. A fish tissue reference material, IAEA-407, was analysed and the mercury concentration was in agreement with the certified value, according to the t-test at a 95% confidence level. The limit of quantification (LOQ), based on a mercury-free sample, was 3.0 µg kg(-1). This LOQ is in accordance with performance criteria required by the Commission Regulation No. 333/2007. Simplicity and high efficiency, without the need for any sample preparation procedure, are some of the qualities of the proposed method.

  2. Hydride generation in-atomizer collection atomic absorption spectrometry for the determination of antimony in acetic acid leachates from pewter cups.

    PubMed

    Dessuy, Morgana B; Kratzer, Jan; Vale, Maria Goreti R; Welz, Bernhard; Dědina, Jiří

    2011-12-15

    Antimony is one of the constituents of pewter, an alloy composed of a minimum of 90% tin with the balance being made up with copper, antimony and perhaps some bismuth. A method has been developed to determine Sb in acetic acid leachates from pewter cups. The employed instrumentation, an atomic absorption spectrometer, equipped with a quartz trap-and-atomizer device, is simple and relatively inexpensive with low running costs. Interferences due to the presence of tin and ways to control them were investigated in detail. The applied approach made possible to overcome potentially serious interference of Sn leached from the cup material (which was shown to take place in the atomizer), by a combination of (i) high concentration of HCl, which decreases the efficiency of stannane generation and (ii) in-atomizer collection. The resulting Sn tolerance limit was between 10 and 20 mg L(-1). The advantages of the in-atomizer collection are a lower tin interference in the atomizer, and a much better limit of detection (LOD), which makes possible reducing the atomization interference further by working with more diluted sample solutions. Besides the Sn interference, an interference of an unknown volatile compound transported to the atomizer together with stibine was identified in the measured sample solutions. This interference could be controlled using the analyte addition technique. The applicability of the method was tested on solutions containing a wide range of interferents leached from the pewter cups, obtained at leaching times between 1 and 24h. The LOD in the sample solutions was found to be 0.03 μg L(-1) Sb.

  3. Redox speciation analysis of dissolved iron in estuarine and coastal waters with on-line solid phase extraction and graphite furnace atomic absorption spectrometry detection.

    PubMed

    Chen, Yaojin; Feng, Sichao; Huang, Yongming; Yuan, Dongxing

    2015-05-01

    An automatic on-line solid phase extraction (SPE) system employing the flow injection (FI) technique directly coupled to a graphite furnace atomic absorption spectrometer (GFAAS) was established for speciation and determination of dissolved iron in estuarine and coastal waters. Fe(II) was mixed with ferrozine solution in a sample stream to form the Fe(II)-ferrozine complex which was extracted onto a C18 SPE cartridge, eluted with eluent and detected with GFAAS. In a parallel flow channel, Fe(III) was reduced to Fe(II) with ascorbic acid and then detected in the same way as Fe(II). The home-made interface between FI-SPE and GFAAS efficiently realized the sample introduction to the furnace in a semi-automated way. Parameters of the FI-SPE system and graphite furnace program were optimized based on a univariate experimental design and an orthogonal array design. The salinity effect on the method sensitivity was investigated. The proposed method provided a detection limit of 1.38 nmol L(-1) for Fe(II) and 1.87 nmol L(-1) for Fe(II+III). With variation of the sample loading volume, a broadened determination range of 2.5-200 nmol L(-1) iron could be obtained. The proposed method was successfully applied to analyze iron species in samples collected from the Jiulongjiang Estuary, Fujian, China. With the 2-cartridge FI-SPE system developed, on-line simultaneous determination of Fe species with GFAAS was achieved for the first time.

  4. On-line speciation and determination of Cr(III) and Cr(VI) in drinking and waste water samples by reversed-phase high performance liquid chromatography coupled with atomic absorption spectrometry.

    PubMed

    Sarica, Deniz Yurtsever; Türker, A Rehber; Erol, Esra

    2006-07-01

    A simple, rapid, and selective on-line method for the speciation and determination of Cr(III) and Cr(VI) in aqueous solutions by ion-pairing HPLC coupled with flame atomic absorption spectrometry (FAAS) is described. The composition of the mobile phase has been optimized for better separation. The effects of column temperature, volume of injection loop, fuel flow rate of FAAS, and nebulizer suction rate of FAAS have also been investigated. Separation is accomplished in almost 2.5 min on a 25 cm length C18 column at 40 degrees C. The selectivity of the method has been established by investigating the effect of interfering elements on chromium determination. The detection limit (3sigma) achieved by the method was calculated as 3.7 ng/mL for Cr(III) and 2.0 ng/mL for Cr(VI). The proposed method has been validated by analyzing certified reference material (BCR 544) and successfully applied to the analysis of drinking water and wastewater samples with a relative error below 6%.

  5. Optimization of a new resin, Amberlyst 36, as a solid-phase extractor and determination of copper(II) in drinking water and tea samples by flame atomic absorption spectrometry.

    PubMed

    Kendüzler, Erdal; Türker, Ali Rehber

    2005-11-01

    A new simple and reliable method has been developed to separate and preconcentrate trace copper ion in drinking water and tea samples for subsequent measurement by flame atomic absorption spectrometry (FAAS). The copper ions are adsorbed quantitatively during passage of aqueous solutions through Amberlyst 36 cation exchange resin. After the separation and preconcentration stage, the analyte was eluted with a potassium cyanide solution and determined by FAAS. Different factors including pH of sample solution, sample volume, amount of resin, flow rate of aqueous solution, volume and concentration of eluent, and matrix effects for preconcentration were examined. The analytical figures of merit for the determination of copper are as follows: analytical detection limit (3 sigma), 0.26 microg/L; precision (RSD), 3.1% for 100 microg/L; enrichment factor, 200 (using 1000 mL of sample solution and 5 mL of eluent); time of analysis, 3.5 h (for obtaining enrichment factor of 200); capacity of resin, 125 mg/g. The method was applied for copper determination by FAAS in tap water, commercial natural spring water, commercial treated drinking water, and commercial tea bag sample. The accuracy of the method is confirmed by analyzing tea leaves (GBW 07605). The results demonstrated good agreement with the certified values.

  6. On-line separation and preconcentration of lead(II) by solid-phase extraction using activated carbon loaded with xylenol orange and its determination by flame atomic absorption spectrometry.

    PubMed

    Ensafi, Ali A; Shiraz, A Zendegi

    2008-02-11

    Activated carbon loaded with xylenol orange in a mini-column was used for the highly selective separation and preconcentration of Pb(II) ions. An on-line system for enrichment and the determination of Pb(II) was carried out on flame atomic absorption spectrometry. The conditions of preconcentration and quantitative recovery of Pb(II) from diluted solution, such as pH of aqueous phase, amount of the sorbent, volume of the solutions and flow variables were studied as well as effect of potential interfering ions. Under the optimum conditions, Pb(II) in an aqueous sample was concentrated about 200-fold and the detection limit was 0.4 ng mL(-1) Pb(II). The adsorption capacity of the solid phase was 0.20mg of lead per one gram of the modified activated carbon. The modified activated carbon is stable for several treatments of sample solutions without the need for using any chemical reagent. The recovery of lead(II) from river water, waste water, tap water, and in the following reference materials: SRM 2711 Montana soil and GBW-07605 tea were obtained in the range of 97-104% by the proposed method.

  7. Synthesis and application of a nanoporous ion-imprinted polymer for the separation and preconcentration of trace amounts of vanadium from food samples before determination by electrothermal atomic absorption spectrometry.

    PubMed

    Dadfarnia, Shayessteh; Haji Shabani, Ali Mohammad; Dehghanpoor Frashah, Shahab

    2016-04-01

    A vanadium ion-imprinted polymer was synthesized in the presence of V(V) and N-benzoyl-N-phenyl hydroxyl amine using 4-vinyl pyridine as the monomer, ethylene glycol dimethacrylate as the cross linker and 2,2'-azobis(isobutyronitrile) as the initiator. The imprinted V(V) ions were completely removed by leaching the polymer with 5 mol/L nitric acid, and the polymer structure was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy. The ion-imprinted polymer was used as the sorbent in the development of the solid-phase extraction method for V(V) prior to its determination by electrothermal atomic absorption spectrometry. The maximum sorption capacity for V(V) ions was 26.7 mg/g at pH 4.0. Under the optimum conditions, for a sample volume of 150.0 mL, an enrichment factor of 289.0 and a detection limit of 6.4 ng/L were obtained. The developed method was successfully applied to the determination of vanadium in parsley, zucchini, black tea, rice, and water samples.

  8. Use of Doehlert and constrained mixture designs in the development of a photo-oxidation procedure using UV radiation/H₂O₂ for decomposition of landfill leachate samples and determination of metals by flame atomic absorption spectrometry.

    PubMed

    Bezerra, Marcos A; Souza, Antônio D S; Oliveira, Rafael V; Oliveira, Djalma M; Cardoso, Luiz A M; Sousa Filho, Hélio R

    2015-03-01

    This work proposes the use of photo-oxidation degradation with UV radiation/H2O2 as sample treatment for the determination of Fe, Zn, Mn, Ni and Co in municipal solid waste landfill leachate by flame atomic absorption spectrometry (FAAS). Three variables (pH, irradiation time and buffer concentration) were optimized using Doehlert design and the proportions of mixture components submitted to UV radiation (leachate sample, buffer solution and H2O2 30%, v/v) were optimized using a constrained mixture design. Using the experimental conditions established, this procedure allows limits of detection of 0.075, 0.025, 0.010, 0.075 and 0.041 µg mL-1, and the precision levels expressed as relative standard (%RSD, 0.5 µg mL-1) were 3.6, 1.8, 1.3, 3.3 and 1.7%, for Fe, Mn, Zn, Ni and Co respectively. Recovery tests were carried out for evaluation of the procedure accuracy and recoveries were between 92 and 106% for the studied metals. This procedure has been applied for the analysis of the landfill leachate collected in Jequié, a city of the southwestern region of the State of Bahia, Brazil. The results were compared with those obtained by acid digestion. There was no significant difference between the results obtained by the two methods based on paired t-test at 95% confidence level.

  9. Determination of As, Cd, Pb and Se in DORM-1 dogfish muscle reference material using alkaline solubilization and electrothermal atomic absorption spectrometry with Ir+Rh as permanent modifiers or Pd+Mg in solution

    NASA Astrophysics Data System (ADS)

    Giacomelli, Maria Bertília Oss; Lima, Maria Carminati; Stupp, Volnei; de Carvalho Júnior, Rui Miguel; Borba da Silva, José Bento; Barrera, Pilar Bermejo

    2002-12-01

    In this work, tetramethylammonium hydroxide (TMAH) was used to solubilize the DORM-1 dogfish muscle certified reference material as a model substance for the determination of As, Cd, Pb and Se by electrothermal atomic absorption spectrometry (ET AAS). The sample was mixed with a small amount of TMAH and heated to 60 °C for 10 min in a water bath. After dissolution, As and Se were determined using palladium and magnesium nitrates as a chemical modifier added in solution. For Cd and Pb, best results were obtained with a mixture of 250 μg of each of iridium and rhodium as permanent modifiers. In both cases, the calibration was performed with aqueous solutions in 0.2% v/v HNO 3. The temperature program for each analyte was optimized using pyrolysis and atomization curves established with the fish reference material. The detection limits in dry samples and the characteristic mass values were: Cd 0.005 μg g -1 and 0.9 pg; Pb 0.04 μg g -1 and 7.6 pg; As 0.4 μg g -1 and 13 pg and Se 0.6 μg g -1 and 20 pg, respectively. Results from the determination of these elements in the DORM-1 certified fish reference material were within the 95% confidence interval of the certified values.

  10. Natural analcime zeolite modified with 2,3,5,6-tetra(2-pyridyl)pyrazine for preconcentration and determination of trace amounts of cadmium by flame atomic absorption spectrometry.

    PubMed

    Saljooghi, Amir Shokooh; Saljoghi, Zoheir Shokouh

    2012-10-01

    An analytical method using natural analcime zeolite modified with tppz (2,3,5,6-tetra-pyridylpyrazine) for preconcentration of cadmium, in a column system, and their sequential determination by flame atomic absorption spectrometry (FAAS), was developed. In this work, cadmium was adsorbed onto natural analcime zeolite modified with tppz and then was recovered by nitric acid. Solutions of cadmium were passed through a glass column packed with 100 mg of the sorbent material, at pH 5.0, and cadmium was eluted with 2.0 M HNO(3) at a flow rate of 2.0 ml min(-1). The relative standard deviation (RSD) for eight replicate determinations at the 2.5 μg of cadmium was ±0.94%. The calibration curve using the preconcentration system was linear from 0.01 to 4 μg ml(-1) in final solution with a correlation coefficient of 0.9993. This method was successfully applied for the determination of cadmium in various samples.

  11. Ionic liquid-assisted multiwalled carbon nanotube-dispersive micro-solid phase extraction for sensitive determination of inorganic As species in garlic samples by electrothermal atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Grijalba, Alexander Castro; Escudero, Leticia B.; Wuilloud, Rodolfo G.

    2015-08-01

    A highly sensitive dispersive micro-solid phase extraction (D-μ-SPE) method combining an ionic liquid (IL) and multi-walled carbon nanotubes (MWCNTs) for inorganic As species (As(III) and As(V)) species separation and determination in garlic samples by electrothermal atomic absorption spectrometry (ETAAS) was developed. Trihexyl(tetradecil)phosphonium chloride IL was used to form an ion pair with the arsenomolybdate complex obtained by reaction of As(V) with molybdate ion. Afterwards, 1.0 mg of MWCNTs was dispersed for As(V) extraction and the supernatant was separated by centrifugation. MWCNTs were re-dispersed with tetradecyltrimethylammonium bromide surfactant and ultrasound followed by direct injection into the graphite furnace of ETAAS for As determination. Pyrolysis and atomization conditions were carefully studied for complete decomposition of MWCNTs and IL matrices. Under optimum conditions, an extraction efficiency of 100% and a preconcentration factor of 70 were obtained with 5 mL of garlic extract. The detection limit was 7.1 ng L- 1 and the relative standard deviations (RSDs) for six replicate measurements at 5 μg L- 1 of As were 5.4% and 4.8% for As(III) and As(V), respectively. The proposed D-μ-SPE method allowed the efficient separation and determination of inorganic As species in a complex matrix such as garlic extract.

  12. The use of rapidly synergistic cloud point extraction for the separation and preconcentration of trace amounts of Ni (II) ions from food and water samples coupling with flame atomic absorption spectrometry determination.

    PubMed

    Rahnama, Reyhaneh; Najafi, Marzieh

    2016-03-01

    A novel improved preconcentration method known as rapidly synergistic cloud point extraction (RS-CPE) was established for nickel preconcentration and determination prior to its determination by flame atomic absorption spectrometry. In this work, the traditional CPE pattern was changed and greatly simplified in order to be applicable in metal extraction and detection. This method was accomplished in room temperature in 1 min. Non-ionic surfactant Triton X-114 was used as extractant. Octanol worked as cloud point revulsant and synergic reagent. The various parameters affecting the extraction and preconcentration of nickel such as sample pH, 2,2'-Furildioxime concentration, amounts of octanol, amounts of Triton X-114, type of diluting solvent, extraction time, and ionic strength were investigated and optimized. Under optimal conditions, the calibration curve showed an excellent linearity in the concentration range of 2-200 μg L(-1), and the limit of detection was 0.6 μg L(-1) for nickel. The developed method was successfully applied for the determination of nickel in food and water samples. The results showed that, the proposed method can be used as a cheap, rapid, and efficient method for the extraction and preconcentration of nickel from real samples.

  13. Vortex-assisted surfactant-enhanced-emulsification liquid-liquid microextraction with solidification of floating organic droplet combined with flame atomic absorption spectrometry for the fast determination of cadmium in water samples.

    PubMed

    Peng, Guilong; Lu, Ying; He, Qiang; Mmereki, Daniel; Tang, Xiaohui; Zhong, Zhihui; Zhao, Xiaolong

    2016-01-01

    A novel vortex-assisted surfactant-enhanced-emulsification liquid-liquid microextraction with solidification of floating organic droplet (VSLLME-SFO) was developed for the fast, simple and efficient determination of cadmium (Cd) in water samples followed by flame atomic absorption spectrometry (FAAS). In the VSLLME-SFO process, the addition of surfactant (as an emulsifier), could enhance the mass transfer from the aqueous solution into the extraction solvent. The extraction solvent could be dispersed into the aqueous phase under vigorous shaking with the vortex. In this paper, we investigated the influences of analytical parameters, including pH, extraction solvent type and its volume, surfactant type and its volume, concentration of chelating agent, salt effect and vortex time, on the extraction efficiency of Cd. Under the optimized conditions, the limit of detection was 0.16 μg/L. The analyte enrichment factor was 37.68. The relative standard deviation was 3.2% (10 μg/L, n = 10) and the calibration graph was linear, ranging from 0.5 to 30 μg/L. The proposed method was successfully applied for the analysis of ultra-trace Cd in river water and wastewater samples.

  14. Room-temperature study of iron gall ink impregnated paper degradation under various oxygen and humidity conditions: time-dependent monitoring by viscosity and X-ray absorption near-edge spectrometry measurements.

    PubMed

    Rouchon, Véronique; Duranton, Maroussia; Burgaud, Cédric; Pellizzi, Eleonora; Lavédrine, Bertrand; Janssens, Koen; de Nolf, Wout; Nuyts, Gert; Vanmeert, Frederik; Hellemans, Kevin

    2011-04-01

    Many western manuscripts were written using iron gall inks. These inks can damage the paper via two major mechanisms: (a) acid hydrolysis, enhanced by humidity, and (b) oxidative depolymerization provoked by the presence of oxygen and free iron(II) ions. The degradation of unsized Whatman paper impregnated with different combinations of iron sulfate, gallic acid, and gum arabic was studied at room temperature in order to assess the relative importance of each mechanism. The samples were stored in various environments including a dry and/or an oxygen-free atmosphere. The cellulose depolymerization was monitored by viscometry and related to changes in the oxidation state of iron, determined by X-ray absorption near-edge spectrometry. The results indicate that residual amounts of oxygen (less than 0.1%) promote cellulose depolymerization, whereas the level of relative humidity has no impact. The cellulose depolymerization also appears closely correlated to oxidative mechanisms. Regarding the oxidation of iron, it only occurs in the simultaneous presence of oxygen and moisture, suggesting the occurrence of rustlike oxidative mechanisms. Finally, the presence of gallic acid has a strong influence, which is only partially explained by its capacity to reduce iron(III) to iron(II).

  15. A novel dispersive liquid-liquid microextraction method based on solidification of floating organic drop for preconcentration of Pd(II) by graphite furnace atomic absorption spectrometry after complexation by a thienyl substituted 1,2-ethanediamine.

    PubMed

    Ragheb, Elham; Hashemi, Payman; Alizadeh, Kamal; Ganjali, Mohammad Reza

    2015-01-01

    A novel dispersive liquid-liquid microextraction method based on solidification of floating organic drop (DLLME-SFO) was developed for the preconcentration of ultratrace amounts of palladium (Pd)(II) before its determination by electrothermal atomic absorption spectrometry. Diphenyl ether (m.p. 26°C) was used for the first time as a heavier than water organic solvent in the developed method. Pd was complexed by N,N'-bis(thiophen-2-ylmethylene)ethane-1,2-diamine to be extracted into the dispersed diphenyl ether phase using acetonitril as the disperser solvent. Upon cooling and centrifugation, the organic solvent was sedimented at the bottomn and the aqueous phase was easily decantated. Some factors influencing the extraction efficiency of Pd(II) and its subsequent determination, including extraction and dispersive solvent type and volume, pH of sample solution, concentration of the chelating agent and salting out effect, were studied and optimized both with univariate and multivariate methods. Under the optimized conditions, the calibration graph exhibited linearity over a range of 10 - 120 μg L(-1). The enrichment factor was 83.3, the detection limit for Pd (3σ) was 47 ng L(-1) and the relative standard deviation was 3.2% (n = 10, 1 ng mL(-1)). The method was successfully applied to the determination of trace amounts of Pd(II) in water samples.

  16. Use of a novel medium, the ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate, for liquid-liquid extraction of lead in water and its determination by graphite furnace atomic absorption spectrometry.

    PubMed

    Zaijun, Li; Qiping, Peng; Haixia, Shan

    2007-01-01

    The ionic liquid 1-butyl-3-trimethylsilylimidazolium hexafluorophosphate, abbreviated as [C4tmsim][PF6], was developed as a novel medium for liquid-liquid extraction of lead(II) in water, in which dithizone was used as a metal chelator to form a neutral lead-dithizone complex. Under optimal conditions, the complex was extracted into the [C4tmsim][PF6] phase from aqueous solution and back-extracted with nitric acid solution into the aqueous phase that was used directly for the subsequent determination of Pb. The system using the ionic liquid demonstrated good extraction performance; the extraction and back-extraction efficiencies were 99.8 and 99.7%, respectively, for Pb(II) at 20 microg/L. The above procedure, including the extraction and back-extraction, was used to enrich trace levels of Pb(ll) in a relatively large volume of water samples (1000 mL water), and an enrichment factor of 400 was obtained. The enrichment coupled with graphite furnace atomic absorption spectrometry was successfully applied to the determination of Pb in water. The calibration graph was linear at levels near the detection limits up to > or = 100 ng/L Pb(II). The limits of quantitation and detection for lead in real water samples were 2.5 and 1.0 ng/L, respectively. Lead recoveries of 96.2-103.8% from spiked samples demonstrate the accuracy of the proposed method.

  17. Ligandless surfactant mediated solid phase extraction combined with Fe₃O₄ nano-particle for the preconcentration and determination of cadmium and lead in water and soil samples followed by flame atomic absorption spectrometry: multivariate strategy.

    PubMed

    Jalbani, N; Soylak, M

    2014-04-01

    In the present study, a microextraction technique combining Fe3O4 nano-particle with surfactant mediated solid phase extraction ((SM-SPE)) was successfully developed for the preconcentration/separation of Cd(II) and Pb(II) in water and soil samples. The analytes were determined by flame atomic absorption spectrometry (FAAS). The effective variables such as the amount of adsorbent (NPs), the pH, concentration of non-ionic (TX-114) and centrifugation time (min) were investigated by Plackett-Burman (PBD) design. The important variables were further optimized by central composite design (CCD). Under the optimized conditions, the detection limits (LODs) of Cd(II) and Pb(II) were 0.15 and 0.74 µg/L, respectively. The validation of the proposed procedure was checked by the analysis of certified reference materials of TMDA 53.3 fortified water and GBW07425 soil. The method was successfully applied for the determination of Cd(II) and Pb(II) in water and soil samples.

  18. Separation and preconcentration of Ag(I) in aqueous samples by flotation as an ion-associate using iodide and ferroin followed the determination by flame atomic absorption spectrometry.

    PubMed

    Hosseini, Mohammad Saeid; Hashemi-Moghaddam, Hamid; Kardan-Moghaddam, Gholamreza

    2007-01-01

    A simple method for separation/preconcentration and determination of Ag(I) in aqueous samples is described. The method is based on formation of an ion-associate between Ag(I)-iodide complex and ferroin, which can be floated at the interface of the aqueous/n-heptane phases. The flotation process was carried out using 500-ml aliquot of the aqueous solution and the floated layer was dissolved in 5 ml of 1 M HNO3 containing methanol (50% v/v) as the solvent. The Ag(I) content was then determined by flame atomic absorption spectrometry (FAAS). The method so could be considered as an enrichment process, was achieved to a quantitative feature, when the pH of the solution was adjusted to 4 and the concentrations of iodide and ferroin were about 3.2 x 10(-4) M and 6.25 x 10(-5) M, respectively. The LOD and RSD (n = 7) were obtained 1.0 x 10(-8) M and 2.4%, respectively. It was found that a large number of cations and anions even at high considerably foreign ion/Ag(I) ratios were not interfered. The method was applied satisfactorily to recovery of Ag(I) from different aqueous samples.

  19. Determination of Ultra-trace Rhodium in Water Samples by Graphite Furnace Atomic Absorption Spectrometry after Cloud Point Extraction Using 2-(5-Iodo-2-Pyridylazo)-5-Dimethylaminoaniline as a Chelating Agent.

    PubMed

    Han, Quan; Huo, Yanyan; Wu, Jiangyan; He, Yaping; Yang, Xiaohui; Yang, Longhu

    2017-03-24

    A highly sensitive method based on cloud point extraction (CPE) separation/preconcentration and graphite furnace atomic absorption spectrometry (GFAAS) detection has been developed for the determination of ultra-trace amounts of rhodium in water samples. A new reagent, 2-(5-iodo-2-pyridylazo)-5-dimethylaminoaniline (5-I-PADMA), was used as the chelating agent and the nonionic surfactant TritonX-114 was chosen as extractant. In a HAc-NaAc buffer solution at pH 5.5, Rh(III) reacts with 5-I-PADMA to form a stable chelate by heating in a boiling water bath for 10 min. Subsequently, the chelate is extracted into the surfactant phase and separated from bulk water. The factors affecting CPE were investigated. Under the optimized conditions, the calibration graph was linear in the range of 0.1-6.0 ng/mL, the detection limit was 0.023 ng/mL for rhodium and relative standard deviation was 3.67% (c = 1.0 ng/mL, n = 11).The method has been applied to the determination of trace rhodium in water samples with satisfactory results.

  20. Cobalt internal standard for Ni to assist the simultaneous determination of Mo and Ni in plant materials by high-resolution continuum source graphite furnace atomic absorption spectrometry employing direct solid sample analysis.

    PubMed

    de Babos, Diego Victor; Bechlin, Marcos André; Barros, Ariane Isis; Ferreira, Edilene Cristina; Gomes Neto, José Anchieta; de Oliveira, Silvana Ruella

    2016-05-15

    A new method is proposed for the simultaneous determination of Mo and Ni in plant materials by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS), employing direct solid sample analysis (DSS) and internal standardization (IS). Cobalt was used as internal standard to minimize matrix effects during Ni determinations, enabling the use of aqueous standards for calibration. Correlation coefficients for the calibration curves were typically better than 0.9937. The performance of the method was checked by analysis of six plant certified reference materials, and the results for Mo and Ni were in agreement with the certified values (95% confidence level, t-test). Analysis was made of different types of plant materials used as renewable sources of energy, including sugarcane leaves, banana tree fiber, soybean straw, coffee pods, orange bagasse, peanut hulls, and sugarcane bagasse. The concentrations found for Mo and Ni ranged from 0.08 to 0.63 ng mg(-1) and from 0.41 to 6.92 ng mg(-1), respectively. Precision (RSD) varied from 2.1% to 11% for Mo and from 3.7% to 10% for Ni. Limits of quantification of 0.055 and 0.074 ng were obtained for Mo and Ni, respectively.

  1. Halloysite nanotubes as a solid sorbent in ultrasound-assisted dispersive micro solid-phase extraction for the determination of bismuth in water samples using high-resolution continuum source graphite-furnace atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    Krawczyk-Coda, Magdalena

    2017-03-01

    In this research, a simple, accurate, and inexpensive preconcentration procedure was developed for the determination of bismuth in water samples, using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS). During the preconcentration step, halloysite nanotubes (HNTs) were used as a solid sorbent in ultrasound-assisted dispersive micro solid-phase extraction (USA DMSPE). The influence of the pH of the sample solution, amount of HNTs, and extraction time, as well as of the main parameters of HR CS GFAAS, on absorbance was investigated. The limit of detection was 0.005 μg L- 1. The preconcentration factor achieved for bismuth was 32. The relative standard deviation (RSD) was 4%. The accuracy of this method was validated by analyses of NIST SRM 1643e (Trace elements in water) and TMDA-54.5 (A high level fortified sample for trace elements) certified reference materials. The measured bismuth contents in these certified reference materials were in satisfactory agreement with the certified values according to the t-test for a 95% confidence level. The proposed method has been successfully applied to the determination of bismuth in five different real water samples (seawater, lake water, river water, stream water and rain water).

  2. Development of a new green non-dispersive ionic liquid microextraction method in a narrow glass column for determination of cadmium prior to couple with graphite furnace atomic absorption spectrometry.

    PubMed

    Naeemullah; Kazi, Tasneem Gul; Tuzen, Mustafa; Shah, Faheem; Afridi, Hassan Imran; Citak, Demirhan

    2014-02-17

    Easy and innovative non-dispersive ionic liquid based microextraction (NDILME) has been developed for preconcentration of trace level of cadmium (Cd) in aqueous real surface water samples prior to couple with graphite furnace atomic absorption spectrometry (GFAAS). A 200 cm long narrow glass column containing aqueous solution of standard/sample was used to increase phase transfer ratio by providing more contact area between two medium (aqueous and extractive), which drastically improve the recoveries of labile hydrophobic chelate of Cd ammonium pyrrolidinedithiocarbamate (APDC), into ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate [C4mim][PF6]. Different aspect of the desire method have been investigated and optimized. Under the optimized key experimental variables, limit of detection (LOD) and enhancement factor (EF) were achieved to be 0.5 ng L(-1) and 150, respectively. Reliability of the model method was checked by relative standard deviation (%RSD), which was found to be <5%. Validity and accuracy of the developed method was checked by analysis of certified reference water samples (SLRS-4 Riverine water) using standard addition method. Application of the model method was productively performed by analysis of Cd in real surface water samples (tap and sea).

  3. Zincon-immobilized silica-coated magnetic Fe3O4 nanoparticles for solid-phase extraction and determination of trace lead in natural and drinking waters by graphite furnace atomic absorption spectrometry.

    PubMed

    Jiang, Hong-mei; Yan, Zhong-peng; Zhao, Yue; Hu, Xin; Lian, Hong-zhen

    2012-05-30

    A new protocol using zincon-immobilized silica-coated magnetic Fe(3)O(4) nanoparticles (Zincon-Si-MNPs) as solid-phase extraction (SPE) medium has been developed for the separation and preconcentration of trace lead in water. Various parameters such as pH, extraction time, concentration and volume of eluent, sample volume, and influence of co-existing ions have been investigated in order to establish the optimum conditions for the determination of lead in combination with graphite furnace atomic absorption spectrometry (GFAAS). The detection limit (LOD) of the proposed method for lead based on an enrichment factor of 200 was 10 ng L(-1). The relative standard deviations (RSDs, n=5) were 8.3%, 7.8% and 9.2%, respectively, at 5, 0.5 and 0.05 ng mL(-1) levels. This method has been successfully applied to the analysis of trace lead in natural and drinking water samples and the recoveries for the spiked samples were in the range of 84-104%.

  4. In-situ separation of the matrix for the direct determination of traces of chromium, cobalt, and nickel in titanium dioxide powder by electrothermal atomic-absorption spectrometry with slurry sampling.

    PubMed

    Zhu, X; Hu, B; Wang, L; Li, S; Jiang, Z

    2001-10-01

    A novel method has been developed for the direct determination of traces of chromium, cobalt, and nickel in TiO2 powder; it entails slurry sampling and electrothermal atomic-absorption spectrometry (ETAAS) with a polytetrafluoroethylene (PTFE) slurry (6% m/v) as fluorinating reagent. The factors which could affect the vaporization of the matrix and analytes were studied in detail; the fluorinating vaporization behavior of the analyte both in the slurry and in solution were also investigated. Owing to the in-situ separation of the matrix, the matrix influences were reduced significantly. The proposed method has been applied to the direct determination of traces of chromium, cobalt, and nickel in high-purity TiO2 powder without chemical pretreatment. Under the optimum experimental conditions the detection limits of the analytes (Cr, Co, and Ni) were 1.9 ng g(-1), 2.4 ng g(-1) and 5.4 ng g(-1), respectively, the relative standard deviations (RSD) were 3.4% (n=6, c=7.0 ng mL(-1)), 2.9% (n=6, c=0.70 ng mL(-1)), and 7.6% (n=6, c=4.0 ng mL(-1)), again respectively, and the characteristic masses for Cr, Co, and Ni were 8.4 pg/ 0.0044A, 9.3 pg/0.0044A, and 40.0 pg/0.0044A, respectively.

  5. Separation and preconcentration system based on ultrasonic probe-assisted ionic liquid dispersive liquid-liquid microextraction for determination trace amount of chromium(VI) by electrothermal atomic absorption spectrometry.

    PubMed

    Chen, Hao; Du, Ping; Chen, Jie; Hu, Shenghua; Li, Shengqing; Liu, Hanlan

    2010-04-15

    A novel method of ultrasonic probe-assisted ionic liquid dispersive liquid-liquid microextraction combined with electrothermal atomic absorption spectrometry (ETAAS) was developed for the determination of chromium(VI) species in water samples. In this procedure, the hydrophobic chelate of chromium(VI) with ammonium pyrrolidinedithiocarbamate (APDC) was extracted into the fine droplets of 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim][PF(6)]), which was dispersed into the aqueous sample solution by ultrasonication using an ultrasonic probe. Several variables such as the volume of [Hmim][PF(6)], sample pH, concentration of APDC, and extraction time were investigated in detail. Under the optimum conditions, the limit of detection of the proposed method was 0.07 ng mL(-1) for Cr(VI) and the relative standard deviation for five-replicated determination of 2.0 ng mL(-1) Cr(VI) was 9.2%. The proposed method has been also successfully applied to the determination of chromium(VI) species in lake and tap water samples.

  6. Investigation of (235)U, (226)Ra, (232)Th, (40)K, (137)Cs, and heavy metal concentrations in Anzali international wetland using high-resolution gamma-ray spectrometry and atomic absorption spectroscopy.

    PubMed

    Zare, Mohammad Reza; Kamali, Mahdi; Fallahi Kapourchali, Maryam; Bagheri, Hashem; Khoram Bagheri, Mahdi; Abedini, Ali; Pakzad, Hamid Reza

    2016-02-01

    Measurements of natural radioactivity levels and heavy metals in sediment and soil samples of the Anzali international wetland were carried out by two HPGe-gamma ray spectrometry and atomic absorption spectroscopy techniques. The concentrations of (235)U, (226)Ra, (232)Th, (40)K, and (137)Cs in sediment samples ranged between 1.05 ± 0.51-5.81 ± 0.61, 18.06 ± 0.63-33.36 ± .0.34, 17.57 ± 0.38-45.84 ± 6.23, 371.88 ± 6.36-652.28 ± 11.60, and 0.43 ± 0.06-63.35 ± 0.94 Bq/kg, while in the soil samples they vary between 2.36-5.97, 22.71-38.37, 29.27-42.89, 472.66-533, and 1.05-9.60 Bq/kg for (235)U, (226)Ra, (232)Th, (40)K, and (137)Cs, respectively. Present results are compared with the available literature data and also with the world average values. The radium equivalent activity was well below the defined limit of 370 Bq/kg. The external hazard indices were found to be less than 1, indicating a low dose. Heavy metal concentrations were found to decrease in order as Fe > Mn > Sr > Zn > Cu > Cr > Ni > Pb > Co > Cd. These measurements will serve as background reference levels for the Anzali wetland.

  7. Development and validation of a high-throughput based on liquid chromatography with ultraviolet absorption and mass spectrometry detection method for quantitation of cichoric acid in Echinacea purpurea aerial-based dietary supplements.

    PubMed

    Chen, Pei

    2006-01-01

    A new, rapid, and reproducible reversed-phased liquid chromatography (LC) method with ultraviolet (UV) absorption and/or mass spectrometry (MS) detection has been developed and validated for quantitation of cichoric acid, a major constituent of Echinacea spp. The method involves the use of a short Phenomenex Hydro-RP C18 column (4 microm, 50 mm x 3.0 mm id) and a simple isocratic mobile phase profile. Both UV (diode array detector) and selective-ion monitoring (SIM) at m/z 472.8 were used for quantitation of cichoric acid. The limit of detection was 0.75 ng for UV and 0.15 ng for MS-SIM, and the limit of quantitation was is 2.5 ng for UV and 0.5 ng for MS-SIM. Water-methanol (1 + 1) soluble extracts of 6 commercially available Echinacea purpurea aerial parts-based dietary supplements (EPADS). EPADS were first profiled using a traditional HPLC-UV method. Their UV chromatograms were compared, and cichoric acid was identified to be a key biomarker for EPADS. Then the samples were analyzed by the fast LC-UV/MS method. The turnaround time for a single analysis was 3 min, compared to 15 to 60 min needed for traditional reported LC methods. The high-throughput method was able to separate the cichoric acid peak from peaks of other components in extracts of complex matrixes of EPADS.

  8. Synthesis and application of a new functionalized resin for use in an on-line, solid phase extraction system for the determination of trace elements in waters and reference cereal materials by flame atomic absorption spectrometry.

    PubMed

    Karadaş, Cennet; Turhan, Onur; Kara, Derya

    2013-11-15

    The synthesis and characterization of the resin Amberlite XAD-4 functionalized with 2,6-pyridinedicarboxaldehyde and its application in an on-line system for the preconcentration of cadmium, cobalt, copper, lead and manganese prior to determination using flame atomic absorption spectrometry (FAAS) is proposed. Metal ions retained on the modified resin were eluted using 1.0 mol L(-1) HNO3 solution and aspirated directly to the nebulizer-burner system of a FAAS instrument using a flow injection system. Detection limits (3σ) were determined to be 0.13 μg L(-1) for Cd, 0.29 μg L(-1) for Cu, 0.23 μg L(-1) for Mn, 0.58 μg L(-1) for Co and 2.19 μg L(-1) for Pb using a 10 mL of water sample loading volume. The limits of detection would be 100 times higher with units of μg kg(-1) for the solid samples in which their dilution ratios as (volume/weight) were 100. Enrichment factors ranged from 23.6 to 28.9 (for Co and Mn, respectively). The proposed method was successfully applied to determination of the analytes in natural water samples and certified reference materials.

  9. Comparative study on intestinal metabolism and absorption in vivo of ginsenosides in sulphur-fumigated and non-fumigated ginseng by ultra performance liquid chromatography quadruple time-of-flight mass spectrometry based chemical profiling approach.

    PubMed

    Zhu, He; Shen, Hong; Xu, Jun; Xu, Jin-Di; Zhu, Ling-Ying; Wu, Jie; Chen, Hu-Biao; Li, Song-Lin

    2015-04-01

    Our previous study indicated that sulphur-fumigation of ginseng in post-harvest handling processes could induce chemical transformation of ginsenosides to generate multiple ginsenoside sulphur derivatives. In this study, the influence of sulphur-fumigation on intestinal metabolism and absorption in vivo of ginsenosides in ginseng was sequentially studied. The intestinal metabolic and absorbed profiles of ginsenosides in rats after intra-gastric (i.g.) administration of sulphur-fumigated ginseng (SFG) and non-fumigated ginseng (NFG) were comparatively characterized by a newly established ultra performance liquid chromatography quadruple time-of-flight mass spectrometry (UPLC-QTOF-MS/MS) with electrospray ionization negative (ESI-) mode. A novel strategy based on the characteristic product ions and fragmentation pathways of different types of aglycones (saponin skeletons) and glycosyl moieties was proposed and successfully applied to rapid structural identification of ginsenoside sulphur derivatives and relevant metabolites. In total, 18 ginsenoside sulphur derivatives and 26 ginsenoside sulphur derivative metabolites in the faeces together with six ginsenoside sulphur derivatives in the plasma were identified in the SFG-administrated group but not in the NFG-administrated group. The results clearly demonstrated that the intestinal metabolic and absorbed profiles of ginsenosides in sulphur-fumigated and non-fumigated ginseng were quite different, which inspired that sulphur-fumigation of ginseng should not be recommended before the bioactivity and toxicity of the ginsenoside sulphur derivatives were systematically evaluated.

  10. Determination of palladium, platinum and rhodium in used automobile catalysts and active pharmaceutical ingredients using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis

    NASA Astrophysics Data System (ADS)

    Resano, Martín; Flórez, María del Rosario; Queralt, Ignasi; Marguí, Eva

    2015-03-01

    This work investigates the potential of high-resolution continuum source graphite furnace atomic absorption spectrometry for the direct determination of Pd, Pt and Rh in two samples of very different nature. While analysis of active pharmaceutical ingredients is straightforward and it is feasible to minimize matrix effects, to the point that calibration can be carried out against aqueous standard solutions, the analysis of used automobile catalysts is more challenging requiring the addition of a chemical modifier (NH4F·HF) to help in releasing the analytes, a more vigorous temperature program and the use of a solid standard (CRM ERM®-EB504) for calibration. However, in both cases it was possible to obtain accurate results and precision values typically better than 10% RSD in a fast and simple way, while only two determinations are needed for the three analytes, since Pt and Rh can be simultaneously monitored in both types of samples. Overall, the methods proposed seem suited for the determination of these analytes in such types of samples, offering a greener and faster alternative that circumvents the traditional problems associated with sample digestion, requiring a small amount of sample only (0.05 mg per replicate for catalysts, and a few milligrams for the pharmaceuticals) and providing sufficient sensitivity to easily comply with regulations. The LODs achieved were 6.5 μg g- 1 (Pd), 8.3 μg g- 1 (Pt) and 9.3 μg g- 1 (Rh) for catalysts, which decreased to 0.08 μg g- 1 (Pd), 0.15 μg g- 1 (Pt) and 0.10 μg g- 1 (Rh) for pharmaceuticals.

  11. A photo-oxidation procedure using UV radiation/H 2O 2 for decomposition of wine samples — Determination of iron and manganese content by flame atomic absorption spectrometry

    NASA Astrophysics Data System (ADS)

    dos Santos, Walter N. L.; Brandão, Geovani C.; Portugal, Lindomar A.; David, Jorge M.; Ferreira, Sérgio L. C.

    2009-06-01

    This paper proposes the use of photo-oxidation with UV radiation/H 2O 2 as sample pretreatment for the determination of iron and manganese in wines by flame atomic absorption spectrometry (FAAS). The optimization involved the study of the following variables: pH and concentration of buffer solution, concentrated hydrogen peroxide volume and irradiation time. The evaluation of sample degradation was monitored by measuring the absorbance at the maximum wavelength of red wine (530 nm). Using the experimental conditions established during the optimization (irradiation time of 30 min, oxidant volume of 2.5 mL, pH 10, and a buffer concentration of 0.15 mol L - 1 ), this procedure allows the determination of iron and manganese with limits of detection of 30 and 22 μg L - 1 , respectively, for a 5 mL volume of digested sample. The precision levels, expressed as relative standard deviation (RSD), were 2.8% and 0.65% for iron and 2.7% and 0.54% for manganese for concentrations of 0.5 and 2.0 mg L - 1 , respectively. Addition/recovery tests for evaluation of the accuracy were in the ranges of 90%-111% and 95%-107% for iron and manganese, respectively. This digestion procedure has been applied for the determination of iron and manganese in six wine samples. The concentrations varied from 1.58 to 2.77 mg L - 1 for iron and from 1.30 to 1.91 mg L - 1 for manganese. The results were compared with those obtained by an acid digestion procedure and determination of the elements by FAAS. There was no significant difference between the results obtained by the two methods based on a paired t-test (at 95% confidence level).

  12. Development of a sequential injection dispersive liquid-liquid microextraction system for electrothermal atomic absorption spectrometry by using a hydrophobic sorbent material: determination of lead and cadmium in natural waters.

    PubMed

    Anthemidis, Aristidis N; Ioannou, Kallirroy-Ioanna G

    2010-05-23

    A novel on-line sequential injection (SI) dispersive liquid-liquid microextraction (DLLME) system coupled to electrothermal atomic absorption spectrometry (ETAAS) was developed for metal preconcentration in micro-scale, eliminating the laborious and time consuming procedure of phase separation with centrifugation. The potentials of the system were demonstrated for trace lead and cadmium determination in water samples. An appropriate disperser solution which contains the extraction solvent (xylene) and the chelating agent (ammonium pyrrolidine dithiocarbamate) in methanol is mixed on-line with the sample solution (aqueous phase), resulting thus, a cloudy solution, which is consisted of fine droplets of xylene, dispersed throughout the aqueous phase. Three procedures are taking place simultaneously: cloudy solution creation, analyte complex formation and extraction from aqueous phase into the fine droplets of xylene. Subsequently the droplets were retained on the hydrophobic surface of PTFE-turnings into the column. A part of 30 microL of the eluent (methyl isobutyl ketone) was injected into furnace graphite for analyte atomization and quantification. The sampling frequency was 10 h(-1), and the obtained enrichment factor was 80 for lead and 34 for cadmium. The detection limit was 10 ng L(-1) and 2 ng L(-1), while the precision expressed as relative standard deviation (RSD) was 3.8% (at 0.5 microg L(-1)) and 4.1% (at 0.03 microg L(-1)) for lead and cadmium respectively. The proposed method was evaluated by analyzing certified reference materials and was applied to the analysis of natural waters.

  13. Vortex-assisted surfactant-enhanced emulsification microextraction based on solidification of floating organic drop followed by electrothermal atomic absorption spectrometry for speciation of antimony (ΙΙΙ, V).

    PubMed

    Eftekhari, Mohammad; Chamsaz, Mahmoud; Arbab-Zavar, Mohammad Hossein; Eftekhari, Ali

    2015-01-01

    Vortex-assisted surfactant-enhanced emulsification microextraction based on solidification of floating organic drop (VASEME-SFO) was used for preconcentration and speciation of antimony (ΙΙΙ, V) followed by electrothermal atomic absorption spectrometry (ETAAS). In this procedure, Triton X-114 was used as emulsifier and 1-undecanol was used as extraction solvent. This method is based on the complexation of Sb(ΙΙΙ) with dithizone (as complexing agent) at pH 2 and extraction of the resulting hydrophobic complex into the extraction solvent (1-undecanol) with vortex-assisted liquid phase microextraction, whereas Sb(V) remained in solution. Sb(ΙΙΙ) in extraction solvent was directly analyzed by ETAAS after dilution with ethanol, and Sb(V) was calculated by subtracting Sb(ΙΙΙ) from the total antimony after reducing Sb(V) to Sb(ΙΙΙ) by L-cysteine. Under the optimized condition, the calibration curve was linear in the range of 0.4-8 μg L(-1) of Sb(ΙΙΙ) with a correlation coefficient of 0.9995. The detection limit based on three times of the standard deviation of the blank (n = 8) was 0.09 μg L(-1). The validation and the recovery of the proposed method were performed by the analysis of a certified reference material and spike method. The obtained results were in very good agreements with certified values. The proposed method was successfully applied for the determination of antimony species at trace levels in different water samples.

  14. 2-Nitroso-1-naphthol as a selective reagent for preconcentration of cobalt by vortex assisted combined with solidification of organic droplet and its determination by flame atomic absorption spectrometry.

    PubMed

    Chamsaz, Mahmoud; Eftekhari, Mohammad; Eftekhari, Ali; Yekkebashi, Ali

    2013-11-01

    Highly rapid and selective vortex-assisted liquid-liquid microextraction based on solidification of organic drop has been used for determination of cobalt ion. 2-Nitroso-1-naphthol (2N1N) was used as a selective complexing agent to form stable cobalt-2N1N complex which can be extracted with 1-undecanol at a short time by the assistance of vortex agitator system followed by its determination using flame atomic absorption spectrometry. In vortex assisted, vigorous vortex stream as well as the vibrant effect of vortex system cause very fine droplets of extraction solvent to be produced and extraction occurred at a short time. Some parameters influencing the extraction process such as pH of samples, concentration of 2-nitroso-1-naphthol, extraction solvent volume, extraction time, ionic strength and surfactant addition, as well as interferences were evaluated in detail and optimum conditions were selected. At the optimum conditions, the calibration curve was linear in the range of 15 to 400 μg L(-1) of cobalt ions. The relative standard deviation based on ten replicate analysis of sample solution containing 50 μg L(-1) of cobalt was 3.4%. The detection limit (calculated as the concentration equivalent to three times of the standard deviation of the blank divided by the slope of the calibration curve after preconcentration) was 5.4 μg L(-1). The accuracy of the proposed method was successfully evaluated by the analysis of certified reference materials. This selective and highly rapid method was used for determination of cobalt ions in different water samples.

  15. Combined speciation analysis by X-ray absorption near-edge structure spectroscopy, ion chromatography, and solid-phase microextraction gas chromatography-mass spectrometry to evaluate biotreatment of concentrated selenium wastewaters.

    PubMed

    Lenz, Markus; van Hullebusch, Eric D; Farges, François; Nikitenko, Sergei; Corvini, Philippe F X; Lens, Piet N L

    2011-02-01

    In this study we evaluate the potential of anaerobic granular sludge as an inoculum for the bioremediation of selenium-contaminated waters using species-specific analytical methods. Solid species formed by microbial reduction were investigated using X-ray absorption near-edge structure (XANES) spectroscopy at the selenium K-edge. Furthermore, dissolved selenium species were specifically determined by ion chromatography (IC) and solid-phase microextraction gas chromatography-mass spectrometry (SPME-GC-MS). Least-squares linear combination of the XANES spectra for samples incubated with the highest selenate/selenite concentrations (10(-3) M) show the predominance of elemental selenium and a Se(-I) selenide, such as ferroselite, the thermodynamically most stable iron selenide. In contrast, elemental selenium and Se(-II) selenides are the main species detected at the lower selenate/selenite concentrations. In each repeated fed batch incubation, most aqueous selenite anions were converted into solid selenium species, regardless of the type of electron donor used (acetate or H(2)/CO(2)) and the selenium concentration applied. On the other hand, at higher concentrations of selenate (10(-4) and 10(-3) M), significant amounts of the oxyanion remained unconverted after consecutive incubations. SPME-GC-MS demonstrated selenium alkylation with both electron donors investigated, as dimethyl selenide (DMSe) and dimethyl diselenide (DMDSe). Selenite was even more alkylated in the presence of H(2)/CO(2) (maximum 2156 μg of Se/L o