Science.gov

Sample records for absorption spectrophotometry showed

  1. Computer programs for absorption spectrophotometry.

    PubMed

    Jones, R N

    1969-03-01

    Brief descriptions are given of twenty-two modular computer programs for performing the basic numerical computations of absorption spectrophotometry. The programs, written in Fortran IV for card input and output, are available from the National Research Council of Canada. The input and output formats are standardized to permit easy interfacing to yield more complex data processing systems. Though these programs were developed for ir spectrophotometry, they are readily modified for use with digitized visual and uv spectrophotometers. The operations covered include ordinate and abscissal unit and scale interconversions, ordinate addition and subtraction, location of band maxima and minima, smoothing and differentiation, slit function convolution and deconvolution, band profile analysis and asymmetry quantification, Fourier transformation to time correlation curves, multiple overlapping band separation in terms of Cauchy (Lorentz), Gauss, Cauchy-Gauss product, and Cauchy-Gauss sum functions and cell path length determination from fringe spacing analysis. PMID:20072266

  2. Determination of metals in phospholipids by atomic-absorption spectrophotometry.

    PubMed

    Montford, B; Cribbs, S C

    1969-07-01

    A procedure is described for the determination of sodium, potassium, calcium, magnesium and manganese in phospholipids by atomic-absorption spectrophotometry. The method uses a solution of phospholipid in isopentyl acetate; phosphate interference is controlled by the addition of aqueous lanthanum chloride solution homogenized with ethanol. Standards are prepared in a similar solvent mixture. A comparison between the described method and that of standard additions show it to be free of phospholipid matrix effects. PMID:18960604

  3. Spectrophotometry of six broad absorption line QSOs

    NASA Technical Reports Server (NTRS)

    Junkkarinen, Vesa T.; Burbidge, E. Margaret; Smith, Harding E.

    1987-01-01

    Spectrophotometric observations of six broad absorption-line QSOs (BALQSOs) are presented. The continua and emission lines are compared with those in the spectra of QSOs without BALs. A statistically significant difference is found in the emission-line intensity ratio for (N V 1240-A)/(C IV 1549-A). The median value of (N V)/(C IV) for the BALQSOs is two to three times the median for QSOs without BALs. The absorption features of the BALQSOs are described, and the column densities and limits on the ionization structure of the BAL region are discussed. If the dominant ionization mechanism is photoionization, then it is likely that either the ionizing spectrum is steep or the abundances are considerably different from solar. Collisional ionization may be a significant factor, but it cannot totally dominate the ionization rate.

  4. Electrothermal atomic absorption spectrophotometry of nickel in tissue homogenates.

    PubMed

    Sunderman, F W; Marzouk, A; Crisostomo, M C; Weatherby, D R

    1985-01-01

    A method for analysis of Ni concentrations in tissues is described, which involves (a) tissue dissection with metal-free obsidian knives, (b) tissue homogenization in polyethylene bags by use of a "Stomacher" blender, (c) oxidative digestion with mixed nitric, sulfuric, and perchloric acids, and (d) quantitation of Ni by electrothermal atomic absorption spectrophotometry with Zeeman background correction. The detection limit for Ni in tissues is 10 ng per g, dry weight; the coefficient of variation ranges from 7 to 15 percent, depending on the tissue Ni concentration; the recovery of Ni added in concentration of 20 ng per g, dry weight, to kidney homogenates averages 101 +/- 8 percent (mean +/- SD). In control rats, Ni concentrations are highest in lung (102 +/- 39 ng per g, dry weight) and lowest in spleen (35 +/- 16 ng per g, dry wt.). In descending order of Ni concentrations, the tissues of control rats rank as follows: lung greater than heart greater than bone greater than kidney greater than brain greater than testis greater than fat greater than liver greater than spleen. In rats killed 24 h after sc injection of NiCl2 (0.125 mmol per kg, body weight) Ni concentrations are highest in kidney (17.7 +/- 2.5 micrograms per g, dry weight) and lowest in brain (0.38 +/- 0.14 micrograms per g, dry weight). In descending order of Ni concentrations, the tissues of NiCl2-treated rats rank as follows: kidney much greater than lung greater than spleen greater than testis greater than heart greater than fat greater than liver greater than bone greater than brain.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:4037701

  5. Electrothermal atomic absorption spectrophotometry of nickel in tissue homogenates

    SciTech Connect

    Sunderman, F.W. Jr.; Marzouk, A.; Crisostomo, M.C.; Weatherby, D.R.

    1985-01-01

    A method for analysis of Ni concentrations in tissues is described, which involves (a) tissue dissection with metal-free obsidian knives, (b) tissue homogenization in polyethylene bags by use by a Stomacher blender, (c) oxidative digestion with mixed nitric, sulfuric, and perchloric acids, and (d) quantitation of Ni by electrothermal atomic absorption spectrophotometry with Zeeman background correction. The detection limit for Ni in tissues is 10 ng per g, dry weight; the coefficient of variation ranges from 7 to 15%, depending on the tissue Ni concentration; the recovery of Ni added in concentration of 20 ng per g, dry weight, to kidney homogenates averages 101 +/- 8% (mean +/-SD). In control rats, Ni concentrations are highest in lung (102 +/- 39 ng per g, dry weight) and lowest in spleen (35 +/- 16 ng per g, dry wt.). In descending order of Ni concentrations, the tissues of control rats rank as follows: lung > heart > bone > kidney > brain > testis > fat > liver > spleen. In rats killed 24 h after sc injection of NiCl/sub 2/ (0.125 mmol per kg, body weight) Ni concentrations are highest in kidney (17.7 +/- 2.5 ..mu..g per g, dry weight) and lowest in brain (0.38 +/- 0.14 ..mu..g per g, dry weight). In descending order of Ni concentrations, the tissues of NiCl/sub 2/-treated rats rank as follows: kidney >> lung > spleen > testis > heart > fat > liver > bone > brain. The present method fills the need for an accurate, sensitive, and practical technique to determine tissue Ni concentrations, with stringent precautions to minimize Ni contamination during tissue sampling and processing. 35 references, 5 figures, 1 table.

  6. Electrothermal atomic absorption spectrophotometry of nickel in tissue homogenates.

    PubMed

    Sunderman, F W; Marzouk, A; Crisostomo, M C; Weatherby, D R

    1985-01-01

    A method for analysis of Ni concentrations in tissues is described, which involves (a) tissue dissection with metal-free obsidian knives, (b) tissue homogenization in polyethylene bags by use of a "Stomacher" blender, (c) oxidative digestion with mixed nitric, sulfuric, and perchloric acids, and (d) quantitation of Ni by electrothermal atomic absorption spectrophotometry with Zeeman background correction. The detection limit for Ni in tissues is 10 ng per g, dry weight; the coefficient of variation ranges from 7 to 15 percent, depending on the tissue Ni concentration; the recovery of Ni added in concentration of 20 ng per g, dry weight, to kidney homogenates averages 101 +/- 8 percent (mean +/- SD). In control rats, Ni concentrations are highest in lung (102 +/- 39 ng per g, dry weight) and lowest in spleen (35 +/- 16 ng per g, dry wt.). In descending order of Ni concentrations, the tissues of control rats rank as follows: lung greater than heart greater than bone greater than kidney greater than brain greater than testis greater than fat greater than liver greater than spleen. In rats killed 24 h after sc injection of NiCl2 (0.125 mmol per kg, body weight) Ni concentrations are highest in kidney (17.7 +/- 2.5 micrograms per g, dry weight) and lowest in brain (0.38 +/- 0.14 micrograms per g, dry weight). In descending order of Ni concentrations, the tissues of NiCl2-treated rats rank as follows: kidney much greater than lung greater than spleen greater than testis greater than heart greater than fat greater than liver greater than bone greater than brain.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Teaching Beer's Law and Absorption Spectrophotometry with a Smart Phone: A Substantially Simplified Protocol

    ERIC Educational Resources Information Center

    Kuntzleman, Thomas S.; Jacobson, Erik C.

    2016-01-01

    A very simple protocol for teaching Beer's Law and absorption spectrophotometry using a smart phone is described. Materials commonly found in high school chemistry laboratories or even around the house may be used. Data collection and analysis is quick and easy. Despite the simple nature of the experiment, excellent results can be achieved.

  8. Uranium isotopes quantitatively determined by modified method of atomic absorption spectrophotometry

    NASA Technical Reports Server (NTRS)

    Lee, G. H.

    1967-01-01

    Hollow-cathode discharge tubes determine the quantities of uranium isotopes in a sample by using atomic absorption spectrophotometry. Dissociation of the uranium atoms allows a large number of ground state atoms to be produced, absorbing the incident radiation that is different for the two major isotopes.

  9. Cinchocaine hydrochloride determination by atomic absorption spectrometry and spectrophotometry.

    PubMed

    Abdel-Ghani, Nour T; Youssef, Ahmed F A; Awady, Mohamed A

    2005-05-01

    Two sensitive spectrophotometric and atomic absorption spectrometric procedures have been developed for determination of cinchocaine hydrochloride (Cin.Cl) in pure form and in pharmaceutical formulation. The spectrophotometric method was based on formation of an insoluble colored ion-associate between the cited drug and tetrathiocyanatocobaltate (CoTC) or hexathiocyanatochromate (CrTC) which dissolved and extracted in an organic solvent. The optimal experimental conditions for quantitative extraction such as pH, concentration of the reagents and solvent were studied. Toluene and iso-butyl alcohol proved to be the most suitable solvents for quantitative extraction of Cin-CoTC and Cin-CrTC ion-associates with maximum absorbance at 620 and 555 nm, respectively. The optimum concentration ranges, molar absorptivities, Ringbom ranges and Sandell sensitivities were also evaluated. The atomic absorption spectrometric method is based on measuring of the excess cobalt or chromium in the aqueous solution, after precipitation of the drug, at 240.7 and 357.9 nm, respectively. Linear application ranges, characteristic masses and detection limits were 57.99-361.9, 50.40 and 4.22 microg ml(-1) of Cin.Cl, in case of CoTC, while 37.99-379.9, 18.94 and 0.81 microg ml(-1) in case of CrTC. PMID:15910814

  10. Cinchocaine hydrochloride determination by atomic absorption spectrometry and spectrophotometry.

    PubMed

    Abdel-Ghani, Nour T; Youssef, Ahmed F A; Awady, Mohamed A

    2005-05-01

    Two sensitive spectrophotometric and atomic absorption spectrometric procedures have been developed for determination of cinchocaine hydrochloride (Cin.Cl) in pure form and in pharmaceutical formulation. The spectrophotometric method was based on formation of an insoluble colored ion-associate between the cited drug and tetrathiocyanatocobaltate (CoTC) or hexathiocyanatochromate (CrTC) which dissolved and extracted in an organic solvent. The optimal experimental conditions for quantitative extraction such as pH, concentration of the reagents and solvent were studied. Toluene and iso-butyl alcohol proved to be the most suitable solvents for quantitative extraction of Cin-CoTC and Cin-CrTC ion-associates with maximum absorbance at 620 and 555 nm, respectively. The optimum concentration ranges, molar absorptivities, Ringbom ranges and Sandell sensitivities were also evaluated. The atomic absorption spectrometric method is based on measuring of the excess cobalt or chromium in the aqueous solution, after precipitation of the drug, at 240.7 and 357.9 nm, respectively. Linear application ranges, characteristic masses and detection limits were 57.99-361.9, 50.40 and 4.22 microg ml(-1) of Cin.Cl, in case of CoTC, while 37.99-379.9, 18.94 and 0.81 microg ml(-1) in case of CrTC.

  11. Using high spectral resolution spectrophotometry to study broad mineral absorption features on Mars

    NASA Technical Reports Server (NTRS)

    Blaney, D. L.; Crisp, D.

    1993-01-01

    Traditionally telescopic measurements of mineralogic absorption features have been made using relatively low to moderate (R=30-300) spectral resolution. Mineralogic absorption features tend to be broad so high resolution spectroscopy (R greater than 10,000) does not provide significant additional compositional information. Low to moderate resolution spectroscopy allows an observer to obtain data over a wide wavelength range (hundreds to thousands of wavenumbers) compared to the several wavenumber intervals that are collected using high resolution spectrometers. However, spectrophotometry at high resolution has major advantages over lower resolution spectroscopy in situations that are applicable to studies of the Martian surface, i.e., at wavelengths where relatively weak surface absorption features and atmospheric gas absorption features both occur.

  12. Determination of traces of silver in waters by anion exchange and atomic absorption spectrophotometry

    USGS Publications Warehouse

    Chao, T.T.; Fishman, M. J.; Ball, J.W.

    1969-01-01

    A method has been developed for the accurate determination of 0.1-1 ??g of silver per liter of water. The method permits stabilization of silver in water without loss to container walls. Optimum conditions have been established for the complete recovery of silver from water with an anion-exchange column, for quantitative elution of silver from the resin, and for measurement of silver by atomic absorption spectrophotometry after chelation with ammonium pyrrolidine dithiocarbamate and extraction of the chelate with MIBK. Silver in the 1-10 ??g 1 range can be determined by extraction without pre-concentration on an ion-exchange resin. ?? 1969.

  13. Application of Absorption Spectrophotometry to Study the Seasonal Dynamics of Dissolved Organic Matter in Arctic Streams

    NASA Astrophysics Data System (ADS)

    Bulygina, E. B.; Bunn, A. G.; Chandra, S.; Davydova, A.; Frey, K. E.; Russell-Roy, L.; Schade, J. D.; Sobczak, W. V.; Spektor, V. V.; Zimov, S. A.; Holmes, R.

    2009-12-01

    Climate change is impacting numerous aspects of the Arctic, influencing the contemporary carbon cycle as well as the fate of ancient carbon contained in permafrost. Through hydrologic connections, changes on land are propagated to aquatic and eventually marine ecosystems. Dissolved organic matter (DOM) fluxes are a primary link between the terrestrial-aquatic-marine carbon cycles. We used absorption spectrophotometry (UV-VIS scans from 200-800 nm) to investigate seasonality, quality, and quantity of DOM in tributaries of the Kolyma River in the Siberian Arctic during spring and summer of 2009. Spectral slopes as well as absorbances at specific wavelengths were compared to DOC concentrations, with particular emphasis on seasonal variability of organic matter quantity and quality. Incubation experiments were also conducted to examine photodegradation and microbial consumption of DOM on waters collected in 2009 from the Kolyma watershed and from the Kuparuk and Atigun rivers on the North Slope of Alaska. In contrast to chemical methods to quantify and characterize DOC or its constituents, absorption spectrophotometry provides a relatively simple means of characterizing a large number of samples, even at remote Arctic locations.

  14. [Determination of nine mineral elements in hulless barley by ultraviolet spectrophotometry and flame atomic absorption spectrometry].

    PubMed

    Liu, Jin; Zhang, Huai-Gang

    2010-04-01

    The contents of nine mineral elements, including sulphur, zinc, calcium, magnesium, potassium, sodium, iron, copper and manganese in five hulless barley (Hordeum vulgare L. var. nudum Hook. f.) lines were determined by ultraviolet spectrophotometry and flames atomic absorption spectrometry (FAAS). For the determination of sulphur, the samples were dissolved by magnesia and anhydrous sodium carbonate at 250 degrees C for 0. 5 h and at 550 degrees C for 3 h in the muffle furnace, and then a certain amount of barium chloride was put into the sample solution for colorimetry of the UV-Vs spectrophotometer. For the determination of other eight mineral elements, all of the samples were dissolved by a kind of incinerating method: first, the sample was put into the muffle furnace at 250 degrees C for 0. 5 h and at 550 degrees C for 2.5 h, then two droplets of 50%HNO3 were distributed into each sample, and the last step was putting the sample into the muffle furnace at 550 degrees C for 0.5 h. And then all of the ash was dissolved by 50%HNO3 to 50 milliliter and determined by flames atomic absorption spectrometry. The precision, accuracy, repeatability and stability of the method were discussed too. The results showed that the relative standard deviations (RSD) were between 1.2% and 3.7%; The average recoveries were 97.44%-101.52% and the relative standard deviations (RSD) of sample determination were 1.3%-3.8%. The repeatability experiment showed that the relative standard deviations (RSD) were 2.6%-6.1%. And the content of each mineral element was the same after 24 hours; All these showed that the method has a good precision, accuracy, repeatability and stability. In all the hulless barley samples, the average contents were in the order of K > S > Mg > Ca > Fe > Na > Zn > Mn > Cu, and the contents of zinc, iron and manganese closely related to people's health were relatively higher than other crops. The data of the experiment could provide an accurate and credible evidence

  15. [Determination of trace calcium in pearl eye drops by coprecipitation atomic absorption spectrophotometry].

    PubMed

    Liang, Ai-hui; Jiang, Zhi-liang; Wang, Xiu-li

    2007-01-01

    The trace calcium in pearl eye drops was analyzed by atomic absorption spectrophotometry after the SrNO3-K2 CO3 co-precipitation. The absorbance at 422. 7 nm is linear with the calcium concentration in the range of 0. 0-20. 0 microg x mL(-1). The detection limit is 0. 06 microg x mL(-1) Ca. A new atomic absorption spectrophotometric method was proposed for the determination of calcium in pearl eye drops, with some advantages including high sensitivity, simplicity, rapidity and accuracy. The recovery is in the range of 97. 0%-98. 3%(n=5). The RSD is 0. 4%. It proved a good method for the determination of calcium in pearl eye drops.

  16. Analysis of lithium in deep basalt groundwaters using graphite furnace atomic absorption spectrophotometry

    SciTech Connect

    Dill, J.A.; Marcy, A.D.

    1986-05-01

    Lithium is under consideration for use as a reactive (sorptive) tracer in experiments designed to provide information regarding natural attenuation processes in a basalt-groundwater environment. In support of these activities, background lithium concentrations in samples obtained from a variety of test horizons have been determined using graphite furnace atomic absorption spectrophotometry. Significant interference was observed in these determinations and was found to be due to the presence of silicate in the samples. It was found that these problems could be circumvented through the use of alkaline silicate or synthetic groundwater matrix modifiers. This matrix effect was examined in some detail. Results obtained using the graphite furnace were compared to results obtained using inductively coupled plasma atomic emission spectroscopy.

  17. Removal of iron interferences by solvent extraction for geochemical analysis by atomic-absorption spectrophotometry

    USGS Publications Warehouse

    Zhou, L.; Chao, T.T.; Sanzolone, R.F.

    1985-01-01

    Iron is a common interferent in the determination of many elements in geochemical samples. Two approaches for its removal have been taken. The first involves removal of iron by extraction with methyl isobutyl ketone (MIBK) from hydrochloric acid medium, leaving the analytes in the aqueous phase. The second consists of reduction of iron(III) to iron(II) by ascorbic acid to minimize its extraction into MIBK, so that the analytes may be isolated by extraction. Elements of interest can then be determined using the aqueous solution or the organic extract, as appropriate. Operating factors such as the concentration of hydrochloric acid, amounts of iron present, number of extractions, the presence or absence of a salting-out agent, and the optimum ratio of ascorbic acid to iron have been determined. These factors have general applications in geochemical analysis by atomic-absorption spectrophotometry. ?? 1985.

  18. Determination of butyltin metabolites in the mouse liver by flameless atomic absorption spectrophotometry.

    PubMed

    Uneo, S; Susa, N; Furukawa, Y

    1995-08-01

    A new analytical method for observation of the metabolic status of butyltin compounds in the mouse liver was devised by a combination of extraction, purification and separation followed by quantitative analysis of each butyltin compound. After the extraction of all tin compounds from liver homogenate with ethyl acetate, these compounds were purified by combination of the fractional extract with organic solvents and column chromatography. The purified fraction was also analyzed by thin-layer chromatography, identifying each tin compound from differences in mobility on a silica gel plate. The tin content in the each separated spot on the plates was measured by flameless atomic absorption spectrophotometry after extraction by acid treatment. About 90% of tin was recovered by this method from the liver of mice which had been administered tri- or dibutyltin compound orally. This method will be useful for quantification of each metabolic product formed from butyltin compounds in vivo. PMID:8519922

  19. Determination of mercury in geological materials by continuous-flow, cold-vapor, atomic absorption spectrophotometry

    SciTech Connect

    Kennedy, K.R.; Crock, J.G.

    1987-06-01

    To determine mercury in geological materials, samples are digested with nitric acid and sodium dichromate in a closed teflon vessel. After bringing to a constant weight, the digest is mixed with air and a sodium chloride-hydroxylamine hydrochloride-sulfuric acid solution and then Hg(II) is reduced to Hg/sup 0/ with stannous chloride in a continuous flow manifold. The mercury vapor is then separated and measured using cold vapor atomic absorption spectrophotometry (CV-AAS). For a 100 mg sample the limit of detection is 20 parts-per-billion (ppb) Hg in sample. To obtain a 1% absorption signal, the described method requires 0.21 ppb Hg solution (equal to 16 ppb in sample). Precision is acceptable at less than 1.2% RSD for a 10 ppb Hg aqueous standard. Accuracy is demonstrated by the results of the analysis on standard reference materials. Several elements do interfere but the effect is minimal because either the digestion procedure does not dissolve them (e.g., Au or Pt) or they are normally of low abundance (e.g., Se or Te).

  20. Analysis of long-range bullet entrance holes by atomic absorption spectrophotometry and scanning electron microscopy.

    PubMed

    Ravreby, M

    1982-01-01

    Bullet residue and primer particles were analyzed by scanning electron microscopy with energy dispersive analysis (SEM-EDA) and by flame and flameless atomic absorption spectrophotometry (AAS). The residue and particles were on cloth targets around entrance holes produced by bullets fired at distances of 10 to 200 m. Primer particles and their chemical constituents were almost always detected by SEM-EDA around the holes produced by rifles and pistols fired at long ranges, and in many cases the barium and antimony associated with primer particles were detected by flameless AAS. Particles were also detected by SEM-EDA on the rear of bullets fired into and recovered from wooden blocks. Usually a hole caused by a bullet jacketed with gilding metal could be distinguished from one caused by a bullet jacketed with yellow brass alloy. Paint from bullet tips of military tracers was also detected. Analysis of the various residues around entrance holes provides a means for identifying the type of ammunition used. PMID:7097199

  1. Determination of selenium in meat products by hydride generation atomic absorption spectrophotometry.

    PubMed

    Tinggi, U

    1999-01-01

    Wet digestion using a mixture of nitric, sulfuric, and perchloric acids and an aluminum block digester effectively and rapidly decomposed meat samples for selenium determination by hydride generation atomic absorption spectrophotometry. Digestion did not require constant attention by an operator. Selenium recoveries (range, 94-105%) from National Institute of Standards and Technology standard reference materials and spiked samples were used to validate method accuracy. Coefficients of variation (CVs) of repeatability of in-house reference materials used for precision study were 6.4 and 5.6%, respectively, for seafood mix and mutton liver. Selenium levels in meat products from Brisbane markets varied widely: 0.042-0.142, 0.081-0.42, and 0.050-0.198 microgram/g (wet weight) respectively, for beef, chicken, and pork. Overall, selenium levels in manufactured meat ranged from 0.041 to 0.189 microgram/g. The levels of selenium found in this study were generally lower than those reported in Finland but comparable with those reported in some parts of the United States.

  2. [The determination of chromium in feeds by flame atomic absorption spectrophotometry].

    PubMed

    Wang, Jian; Jia, Bin; Guo, Li-ping; Lin, Qiu-ping

    2005-07-01

    Chromium in feeds is regulated by China Standard GB 13078-2001. A method of flame atomic absorption spectrophotometry for the determination of Cr in feeds has been developed in allusion to shortage of China standard method. Several acetylene flow-rate, burner-high and the additive of interference suppressor NH4Cl were studied respectively on the effect of sensitivities of Cr(III) and Cr(VI). The two sets analytical average results of Cr in feed sample determined by calibration curves of Cr(III) and Cr(VI) were tested by t test, no marked discrepancy was found. Optimum instrumental conditions of Cr(III) and Cr(VI) with same sensitivity were confirmed. Sensitivity was 0.014 microg x mL(-1) with detection limit 0.70 mg x kg(-1). The recoveries were 94.4%-104.9%. Relative standard deviation of sample determination (5-6 times) was 1.90%-4.08%. This method is simply, fast and exact, the detection limit was answered for Cr limit in feeds regulated by GB 13078-2001, it can be applied to the analysis of Cr in feeds.

  3. Quantification of minerals and trace elements in raw caprine milk using flame atomic absorption spectrophotometry and flame photometry.

    PubMed

    Singh, Mahavir; Yadav, Poonam; Garg, V K; Sharma, Anshu; Singh, Balvinder; Sharma, Himanshu

    2015-08-01

    This study reports minerals and trace elements quantification in raw caprine milk of Beetal breed, reared in Northern India and their feed, fodder & water using flame atomic absorption spectrophotometry and flame photometry. The mineral and trace elements' concentration in the milk was in the order: K > Ca > Na > Fe > Zn > Cu. The results showed that minerals concentration in caprine milk was lesser than reference values. But trace elements concentration (Fe and Zn) was higher than reference values. Multivariate statistical techniques, viz., Pearsons' correlation, Cluster analysis (CA) and Principal component analysis (PCA) were applied to analyze the interdependences within studied variables in caprine milk. Significantly positive correlations were observed between Fe - Zn, Zn - K, Ca - Na and Ca - pH. The results of correlation matrix were further supported by Cluster analysis and Principal component analysis as primary cluster pairs were found for Ca - pH, Ca - Na and Fe - Zn in the raw milk. No correlation was found between mineral & trace elements content of the milk and feed. PMID:26243956

  4. Quantification of minerals and trace elements in raw caprine milk using flame atomic absorption spectrophotometry and flame photometry.

    PubMed

    Singh, Mahavir; Yadav, Poonam; Garg, V K; Sharma, Anshu; Singh, Balvinder; Sharma, Himanshu

    2015-08-01

    This study reports minerals and trace elements quantification in raw caprine milk of Beetal breed, reared in Northern India and their feed, fodder & water using flame atomic absorption spectrophotometry and flame photometry. The mineral and trace elements' concentration in the milk was in the order: K > Ca > Na > Fe > Zn > Cu. The results showed that minerals concentration in caprine milk was lesser than reference values. But trace elements concentration (Fe and Zn) was higher than reference values. Multivariate statistical techniques, viz., Pearsons' correlation, Cluster analysis (CA) and Principal component analysis (PCA) were applied to analyze the interdependences within studied variables in caprine milk. Significantly positive correlations were observed between Fe - Zn, Zn - K, Ca - Na and Ca - pH. The results of correlation matrix were further supported by Cluster analysis and Principal component analysis as primary cluster pairs were found for Ca - pH, Ca - Na and Fe - Zn in the raw milk. No correlation was found between mineral & trace elements content of the milk and feed.

  5. [Study on determination of eight metal elements in Hainan arecanut leaf by flame atomic absorption spectrophotometry].

    PubMed

    Liu, Li-yun; Wang, Ping; Feng, Mei-li; Dong, Zhi-guo; Li, Jie

    2008-12-01

    Arecanut is a sort of palm that is important economic crop for the farmers in Hainan province of China, wherein there are many kinds of metal elements such as K, Ca, Na, Mg, Fe, Mn, Cu, Zn etc. These elements are important nutrition for the growth of arecanut. It is very valuable to study on the content of these metal elements in arecanut leaf in terms of plant nutriology of arecanut. The arecanut leaf in Wangling county, Hainan province of China was sampled by diagonal-field-sampling method. Refering to other plant sample determination by FAAS, the detailed studies are done with different digestion and determination methods. In the present paper the effects of mixed acid of HNO3-HClO4 digestion method on determining the amount of metal elements in the arecanut leaf by FAAS is reported, and another one is incineration digestion method. FAAS method was established for the determination of K, Ca, Mg, Na, Fe, Mn, Cu and Zn The samples were incinerated or heated with HNO3-HClO4 (4:1). In the meantime, the optimum parameters of FAAS and effects of different digestion methods on the results were discussed. The recovery rate of standard addition is 98.36%-102.38% in the first method; RSD is 0.42%-2.328% (n=6); The recovery rate of standard addition is 99.22%-103.72% in the second method; RSD is 0.58%-1.283 (n=6). The metal amount determined by the first method is lower than the second method, the ratio is 0.9703-0.9934. The two methods are satisfied, but the latter is better. It is precise enough to common experiment to use flame atomic absorption spectrophotometry with digestion by incineration If the especially precise experiment is required, the digestion methods with mixed acid of HNO3-HClO4 may be introduced. The paper introduced methods dependable for determination of some metal elements in order to study on some nutrient effects of these metal elements in arecanut. PMID:19248529

  6. Determination of silver in soils, sediments, and rocks by organic-chelate extraction and atomic absorption spectrophotometry

    USGS Publications Warehouse

    Chao, T.T.; Ball, J.W.; Nakagawa, H.M.

    1971-01-01

    A useful method for the determination of silver in soil, sediment, and rock samples in geochemical exploration has been developed. The sample is digested with concentrated nitric acid, and the silver extracted with triisooctyl thiophosphate (TOTP) in methyl isobutyl ketone (MIBK) after dilution of the acid digest to approximately 6 M. The extraction of silver into the organic extractant is quantitative and not affected by the nitric acid concentration from 4 M to 8 M, or by different volumes of TOTP-MIBK. The extracted silver is stable and remains in the organic phase up to several days. The silver concentration is determined by atomic absorption spectrophotometry. ?? 1971.

  7. [Use of solubilization for the preparation of samples for determination of heavy metals in biological materials using atomic absorption spectrophotometry].

    PubMed

    Pfüller, U; Fuchs, V; Golbs, S; Ebert, E; Pfeifer, D

    1980-01-01

    Solubilisation was tested for its suitability to prepare organic samples for metal determination. Flameless atomic-absorption spectrophotometry was used as test method. Copper, manganese, zinc, and chromium levels were determined from various organ systems of Wistar rat, in response to "normal" feeding of pelletised standard feed. A comparison between experimentally established concentrations, on the one hand, and literature data, on the other, suggested that solubilisation was applicable with good success to the preparation of samples from which to determine reliable values, in ppm and ppb, of the above elements. PMID:7436671

  8. Aqueous complexation of citrate with neodymium(III) and americium(III): a study by potentiometry, absorption spectrophotometry, microcalorimetry, and XAFS.

    PubMed

    Brown, M Alex; Kropf, A Jeremy; Paulenova, Alena; Gelis, Artem V

    2014-05-01

    The aqueous complexation of Nd(III) and Am(III) with anions of citrate was studied by potentiometry, absorption spectrophotometry, microcalorimetry, and X-ray absorption fine structure (XAFS). Using potentiometric titration data fitting the metal-ligand (L) complexes that were identified for Nd(III) were NdHL, NdL, NdHL2, and NdL2; a review of trivalent metal-citrate complexes is also included. Stability constants for these complexes were calculated from potentiometric and spectrophotometric titrations. Microcalorimetric results concluded that the entropy term of complex formation is much more dominant than the enthalpy. XAFS results showed a dependence in the Debye-Waller factor that indicated Nd(iii)-citrate complexation over the pH range of 1.56-6.12.

  9. Comparison of four methods for digesting food samples for determination of trace levels of cadmium by flameless atomic absorption spectrophotometry

    SciTech Connect

    Cabanis, M.T.; Cassanas, G.; Cabanis, J.C.; Brun, S.

    1988-01-01

    The authors compared 4 digestion procedures, namely, sulfuric-nitric acid in an open flask, nitric acid under pressure, sulfuric-nitric acid with refluxing, and nitric-hydrochloric-peroxide with refluxing, for the determination of cadmium by flameless atomic absorption spectrophotometry in 3 foodstuffs: rice, beef, and cream cheese. The foodstuffs were homogenized and divided into several batches for analysis. The results were evaluated using a 2-way cross analysis of variance. The study revealed that the digestion procedure was a highly significant factor (P < 10/sup -4/) in the analysis of the 3 foods; whereas the nature of the foodstuffs was not significant for rice and meat and only slightly significant (P < 10/sup -2/) for cream cheese. When the foodstuffs were spiked with a known amount of cadmium, they observed a loss of the metal when the sulfuric-nitric acid procedure in an open flask and the nitric-hydrochloric-peroxide digestion procedure were used. Taken together, the results of the present study indicate that the choice of the reagents used for digestion of foodstuffs is a crucial factor for cadmium determination by flameless atomic absorption spectrophotometry.

  10. Determination of Pb in Biological Samples by Graphite Furnace Atomic Absorption Spectrophotometry: An Exercise in Common Interferences and Fundamental Practices in Trace Element Determination

    ERIC Educational Resources Information Center

    Spudich, Thomas M.; Herrmann, Jennifer K.; Fietkau, Ronald; Edwards, Grant A.

    2004-01-01

    An experiment is conducted to ascertain trace-level Pb in samples of bovine liver or muscle by applying graphite furnace atomic absorption spectrophotometry (GFAAS). The primary objective is to display the effects of physical and spectral intrusions in determining trace elements, and project the usual methods employed to minimize accuracy errors…

  11. 25. View down launch tube, showing shock absorption system. Lyon ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. View down launch tube, showing shock absorption system. Lyon - Whiteman Air Force Base, Minuteman Missile Launch Facility Trainer T-12, Northeast of Oscar-01 Missile Alert Facility, Knob Noster, Johnson County, MO

  12. [Determination of compound preparation containing unknown absorptive background by UV spectrophotometry].

    PubMed

    Guo, Y L; Xiang, B R; An, D K

    1991-01-01

    A novel algorithm of target factor analysis has been developed for detection and correction of unknown absorptive background in multicomponent analysis. The algorithm is based on the property that the estimated spectra can gradually approach the true ones by iterative refinements. Paracetamol and antipyrine contained in compound injection of paracetamol were determined by this method without any preliminary chemical separation. The average recoveries were both 100.0% and the coefficients of variation were 1.1% and 1.0% respectively. The results clearly indicate that the proposed method may also provide a new approach to the analysis of traditional Chinese medicine containing some unknown absorptive components. PMID:1789114

  13. Determination of platinum, palladium, and lead in biological samples by atomic absorption spectrophotometry.

    PubMed Central

    Tillery, J B; Johnson, D E

    1975-01-01

    A flameless atomic absorption method for the coextraction of platinum and palladium from biological and environmental samples by high molecular weight amine (HMWA) is given. Also, methods for lead determination in biological samples by use of extraction flameless analysis and direct aspiration-flame analysis are reported. A study of lead contamination of Vacutainer tubes is given. PMID:1227857

  14. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of antimony by automated-hydride atomic absorption spectrophotometry

    USGS Publications Warehouse

    Brown, G.E.; McLain, B.J.

    1994-01-01

    The analysis of natural-water samples for antimony by automated-hydride atomic absorption spectrophotometry is described. Samples are prepared for analysis by addition of potassium and hydrochloric acid followed by an autoclave digestion. After the digestion, potassium iodide and sodium borohydride are added automatically. Antimony hydride (stibine) gas is generated, then swept into a heated quartz cell for determination of antimony by atomic absorption spectrophotometry. Precision and accuracy data are presented. Results obtained on standard reference water samples agree with means established by interlaboratory studies. Spike recoveries for actual samples range from 90 to 114 percent. Replicate analyses of water samples of varying matrices give relative standard deviations from 3 to 10 percent.

  15. Development of mixed-waste analysis capability for graphite furnace atomic absorption spectrophotometry

    SciTech Connect

    Bass, D.A.; TenKate, L.B.; Wroblewski, A.

    1995-03-01

    Graphite furnace atomic absorption spectrophotometer (GFAAS) are typically configured with ventilation to capture potentially toxic and corrosive gases emitted from the vaporization of sample aliquots. When radioactive elements are present, additional concerns (such as meeting safety guidelines and ALARA principles) must be addressed. This report describes a modification to a GFAAS that provides additional containment of vaporized sample aliquots. The modification was found to increase containment by a factor of 80, given expected operating conditions. The use of the modification allows more mixed-waste samples to be analyzed, permits higher levels of radioactive samples to be analyzed, or exposes the analyst to less airborne radioactivity. The containment apparatus was attached to a Perkin-Elmer Zeeman 5000 spectrophotometer for analysis of mixed-waste samples; however, it could also be used on other systems and in other applications where greater containment of vaporized material is desired.

  16. Determination of soluble aluminium concentration in alkaline humic water using atomic absorption spectrophotometry.

    PubMed

    Nguyen, K L; Lewis, D M; Jolly, M; Robinson, J

    2004-11-01

    The steps of the standard method to determine soluble aluminium concentration are filtering, followed by acidifying, then analysing with the atomic absorption spectrophotometer (AAS). When applied to alkaline humic water, acidification gives rise to the formation of humic acid as a brown particulate matter. Of the total soluble aluminium in the original water, 49-61% forms complexes with the particulate humic acid upon acidification. Although the AAS is capable of detecting the binding aluminium, the particulate nature of humic acid easily induces inaccurate readings as a result of the non-uniform distribution of the particulate matter. A more precise analysis of soluble aluminium concentration of alkaline humic water is shown to be achievable in basicified solutions instead. Basicified solutions keep humic acid in the soluble form; hence maintain the homogeneity of the sample.

  17. Measurement of aluminum in neuronal tissues using electrothermal atomization atomic absorption spectrophotometry

    SciTech Connect

    Pierson, K.B.; Evenson, M.A.

    1986-07-01

    Studies characterizing aluminum complexes isolated from neuronal tissues require accurate and precise techniques for aluminum measurement. A solution of 0.01 M nitric acid containing 0.2% Triton X-100 was the optimal diluent for aluminum measurement under the experimental conditions used. Three National Bureau of Standards Standard Reference Materials (SRM) were digested, and the aluminum concentration of each was measured with a Perkin-Elmer 503 atomic absorption spectrophotometer equipped with a Perkin-Elmer HGA 2100 controller. The calculated detection limit of aluminum was 120 pg using 15-..mu..L sample injections (8 ..mu..g/L). Aluminum concentrations present in citrus leaves (SRM 1572), pine needles (SRM 1575), and tomato leaves (SRM 1573) were 100 +- 12 (certified value, 92 +- 15), 522 +- 45 (certified value, 454 +- 30), and 1273 +- 112 (provisional value, 1200) ..mu..g/g, respectively. The within- and between-day precision had coefficients of variation for citrus leaves, pine needles, and tomato leaves of 18 and 12%, 6.3 and 8.6%, and 3.7 and 8.7%, respectively. Aluminum absorbance was enhanced at high pH values and by zinc.

  18. Sample preparation in determination of lead in garden vegetables by flame atomic absorption spectrophotometry.

    PubMed

    Preer, J R; Stephens, B R; Bland, C W

    1982-07-01

    Dry and wet ashing methods have been used in the analysis of garden vegetables for Pb. The reliability of wet ashing has been verified by the method of standard additions. Comparison of dry and wet ashing showed good agreement for a variety of garden vegetables. Sample size was more strictly limited for the wet-ashed samples, which led to lower sensitivity. Vegetable samples are commonly analyzed for a number of trace elements, which introduces additional constraints on sample preparation, notably because of Cd loss on dry ashing. Pretreatment with HNO3/H2SO4 ash aid eliminated Cd loss. Reliability of dry ashing with pretreatment was shown with NBS SRM Orchard Leaves, Pine Needles, Spinach, and Tomato Leaves. The analysis was insensitive to ashing temperature in the range 480-625 degrees C. A practical detection limit for the method is about 2 ppm Pb, dry weight basis (DWB). Care must be exercised to avoid contamination of the sample with lead at this level by improper handling. Segregation and acid washing of glassware and protection of the sample from contact with any object not demonstrably clean was necessary. No evidence was found of Pb contamination at this level from tap water washing of fresh vegetables, forced-air oven drying, or grinding with mortar and pestle. No special clean room facilities or laboratory air purification measures were used. Sensitivity was increased 3-fold by extraction with dithizone in CHCl3 followed by back-extraction into dilute HCl. Detection limits were not improved, however, because of variation in the extraction results. The instrumental method for assessing effective correction for back-ground absorbance showed adequate compensation, although comparison of direct and extractive determinations showed a small but significant difference between the methods of about 1 ppm Pb (DWB).

  19. [Application of solid sampling graphite furnace atomic absorption spectrophotometry to mensuration of brain iron content in rats].

    PubMed

    Zhang, Nan; Sheng, Qing-hai; Shi, Zhen-hua; Zhang, Zhi-guo; Duan, Xiang-lin; Chang, Yan-zhong

    2009-04-01

    In the present study, the authors performed the solid sampling and detected the iron levels in cortex, hippocampus and striatum of rat brain by GFAAS. The authors' results showed that there are no remarkable difference between the data obtained by solid sampling graphite furnace atomic absorption and liquid sampling graphite furnace atomic absorption. Compared to liquid sampling graphite furnace atomic absorption, the sample pre-treatment stage was obviously simplified, the cost was reduced significantly, and the time was shortened significantly in the solid sampling GFAAS. This study will be beneficial to the mensuration of iron content in micro-tissue of animal by solid sampling GFASS.

  20. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of chromium in water by graphite furnace atomic absorption spectrophotometry

    USGS Publications Warehouse

    McLain, B.J.

    1993-01-01

    Graphite furnace atomic absorption spectrophotometry is a sensitive, precise, and accurate method for the determination of chromium in natural water samples. The detection limit for this analytical method is 0.4 microg/L with a working linear limit of 25.0 microg/L. The precision at the detection limit ranges from 20 to 57 percent relative standard deviation (RSD) with an improvement to 4.6 percent RSD for concentrations more than 3 microg/L. Accuracy of this method was determined for a variety of reference standards that was representative of the analytical range. The results were within the established standard deviations. Samples were spiked with known concentrations of chromium with recoveries ranging from 84 to 122 percent. In addition, a comparison of data between graphite furnace atomic absorption spectrophotometry and direct-current plasma atomic emission spectrometry resulted in suitable agreement between the two methods, with an average deviation of +/- 2.0 microg/L throughout the analytical range.

  1. Intramolecular electron transfer versus substrate oxidation in lactoperoxidase: investigation of radical intermediates by stopped-flow absorption spectrophotometry and (9-285 GHz) electron paramagnetic resonance spectroscopy.

    PubMed

    Fielding, Alistair J; Singh, Rahul; Boscolo, Barbara; Loewen, Peter C; Ghibaudi, Elena M; Ivancich, Anabella

    2008-09-16

    We have combined the information obtained from rapid-scan electronic absorption spectrophotometry and multifrequency (9-295 GHz) electron paramagnetic resonance (EPR) spectroscopy to unequivocally determine the electronic nature of the intermediates in milk lactoperoxidase as a function of pH and to monitor their reactivity with organic substrates selected by their different accessibilities to the heme site. The aim was to address the question of the putative catalytic role of the protein-based radicals. This experimental approach allowed us to discriminate between the protein-based radical intermediates and [Fe(IV)=O] species, as well as to directly detect the oxidation products by EPR. The advantageous resolution of the g anisotropy of the Tyr (*) EPR spectrum at high fields showed that the tyrosine of the [Fe(IV)=O Tyr (*)] intermediate has an electropositive and pH-dependent microenvironment [g(x) value of 2.0077(0) at pH >or= 8.0 and 2.0066(2) at 4.0

  2. Determination of arsenic in urine by atomic absorption spectrophotometry for biological monitoring of occupational exposure to arsenic.

    PubMed

    Dang, T M; Tran, Q T; Vu, K V

    1999-09-01

    An atomic absorption spectrophotometric (AAS) method was successfully applied to analysis of urine for arsenic (As) as a measure of biological monitoring of occupational exposure to As in Vietnam. The application of the method to urine samples from 75 non-exposed control urbanites (after 2-day abstinence from sea foods) gave a reference level of 62.4 +/- 11.6 microg/l (as mean +/- S.D.), from which the upper limit of the normal value (74 microg/l as mean +/- 1 S.D.) and the acceptable limit (100 microg/l as mean +/- 3S.D.) were deduced. Further application to urine samples from 147 workers occupationally exposed to As in Bacthai Non-ferrous Metallurgic Corporation showed significantly elevated levels of As in urine, with mean +/- S.D. of 78.5 +/- 20.2 microg/l. Improvement of working conditions to reduce As exposure resulted in substantial reduction in the ratio of those with urinary As at the level in excess of the acceptable limit. The practical importance of total arsenic determination in urine after 2-day sea food abstinence is discussed in connection with current conditions in analytical laboratories in Vietnam.

  3. Determination of Copper by Graphite Furnace Atomic Absorption Spectrophotometry: A Student Exercise in Instrumental Methods of Analysis.

    ERIC Educational Resources Information Center

    Williamson, Mark A.

    1989-01-01

    Discusses a student exercise which requires the optimizing of the charring and atomization temperatures by producing a plot of absorbance versus temperature for each temperature parameter. Notes that although the graphite furnace atomic absorption spectroscopy technique has widespread industrial use, there are no published, structured experiments…

  4. Matrix effects on the determination of manganese in geological materials by atomic-absorption spectrophotometry under different flame conditions

    USGS Publications Warehouse

    Sanzolone, R.F.; Chao, T.T.

    1978-01-01

    Suppression caused by five of the seven matrix elements studied (Si, Al, Fe, Ca and Mg) was observed in the atomic-absorption determination of manganese in geological materials, when synthetic solutions and the recommended oxidizing air-acetylene flame were used. The magnitude of the suppression effects depends on (1) the kind and concentration of the interfering elements, (2) the type of acid medium, and (3) the concentration of manganese to be determined. All interferences noted are removed or alleviated by using a reducing nitrous oxide-acetylene flame. The atomic-absorption method using this flame can be applied to the determination of total and extractable manganese in a wide range of geological materials without interferences. Analyses of six U.S. Geological Survey rock standards for manganese gave results in agreement with the reported values. ?? 1978.

  5. Graphite furnace atomic absorption spectrophotometry--a novel method to quantify blood volume in experimental models of intracerebral hemorrhage.

    PubMed

    Kashefiolasl, Sepide; Foerch, Christian; Pfeilschifter, Waltraud

    2013-02-15

    Intracerebral hemorrhage (ICH) accounts for 10% of all strokes and has a significantly higher mortality than cerebral ischemia. For decades, ICH has been neglected by experimental stroke researchers. Recently, however, clinical trials on acute blood pressure lowering or hyperacute supplementation of coagulation factors in ICH have spurred an interest to also design and improve translational animal models of spontaneous and anticoagulant-associated ICH. Hematoma volume is a substantial outcome parameter of most experimental ICH studies. We present graphite furnace atomic absorption spectrophotometric analysis (AAS) as a suitable method to precisely quantify hematoma volumes in rodent models of ICH.

  6. Estimation of perimortal percent carboxy-heme in nonstandard postmortem specimens using analysis of carbon monoxide by GC/MS and iron by flame atomic absorption spectrophotometry.

    PubMed

    Middleberg, R A; Easterling, D E; Zelonis, S F; Rieders, F; Rieders, M F

    1993-01-01

    In decomposed, formalin-fixed, embalmed, exhumed, and some fire-dried cases in which normal blood is unavailable, the usual methods for determination of carboxyhemoglobin saturation frequently fail. To address these specimens, a method utilizing both gas chromatography/mass spectrometric (GC/MS) determination of carbon monoxide (CO) and flame atomic absorption spectrophotometry (FAAS) determination of iron (Fe), in the same specimen, was developed. The method is reported here, along with its application to seven pertinent forsensic death investigations. The CO analytical methodology involves acid liberation of the gas from the specimen aliquot in a headspace vial. After heating and equilibrating, a sample of the headspace vapor is injected into the GC/MS system with a gastight syringe. Quantitation is achieved by standard addition comparison utilizing the ideal gas law equation. Iron is quantified by FAAS analysis of the same aliquot used for the CO determination, following nitric acid digestion. The concentration is determined by comparison to a standard curve. A formula for determining the minimum percent carboxy-heme saturation was derived by using the ratio of the amount of CO to the amount of Fe in the aliquot analyzed. Tissue types analyzed include spleen, liver, muscle, dried blood, and unspecified decomposed tissue.

  7. Estimation of perimortal percent carboxy-heme in nonstandard postmortem specimens using analysis of carbon monoxide by GC/MS and iron by flame atomic absorption spectrophotometry.

    PubMed

    Middleberg, R A; Easterling, D E; Zelonis, S F; Rieders, F; Rieders, M F

    1993-01-01

    In decomposed, formalin-fixed, embalmed, exhumed, and some fire-dried cases in which normal blood is unavailable, the usual methods for determination of carboxyhemoglobin saturation frequently fail. To address these specimens, a method utilizing both gas chromatography/mass spectrometric (GC/MS) determination of carbon monoxide (CO) and flame atomic absorption spectrophotometry (FAAS) determination of iron (Fe), in the same specimen, was developed. The method is reported here, along with its application to seven pertinent forsensic death investigations. The CO analytical methodology involves acid liberation of the gas from the specimen aliquot in a headspace vial. After heating and equilibrating, a sample of the headspace vapor is injected into the GC/MS system with a gastight syringe. Quantitation is achieved by standard addition comparison utilizing the ideal gas law equation. Iron is quantified by FAAS analysis of the same aliquot used for the CO determination, following nitric acid digestion. The concentration is determined by comparison to a standard curve. A formula for determining the minimum percent carboxy-heme saturation was derived by using the ratio of the amount of CO to the amount of Fe in the aliquot analyzed. Tissue types analyzed include spleen, liver, muscle, dried blood, and unspecified decomposed tissue. PMID:8429619

  8. Optimisation of Direct Copper Determination in Human Breast Milk Without Digestion by Zeeman Graphite Furnace Atomic Absorption Spectrophotometry with Two Chemical Modifiers.

    PubMed

    Pineau, Alain; Fauconneau, Bernard; Marrauld, Annie; Lebeau, Alexandra; Hankard, Regis; Guillard, Olivier

    2015-08-01

    Milk is an important food in the human diet, and copper (Cu) in human milk is indispensable to children's normal growth and development. It is consequently important that Cu deficiency, occurring in malnourished women or in malabsorption following bariatric surgery, be prevented. The objective of this work is to provide hospital-based paediatricians with a tool enabling rapid measurement of Cu in human breast milk through a technique that biology laboratories can easily apply. Using electrothermal atomic absorption spectrophotometry with Zeeman correction, we have optimized this method with two chemical modifiers and without digestion for analytical procedure. Detection limits and quantification limits for Cu in human milk were found to be 0.077 and 0.26 μmol/L, respectively. Within-run (n = 30) and between-run (n = 15) variations in a pool of human milk samples were 1.50 and 3.62%, respectively. Average recoveries ranged from 98.67 to 100.61%. The reliability of this method was also confirmed by analysing certified reference material (10%). In breast milk samples collected from 100 lactating mothers, Cu mean (±1 SD) was 7.09 ± 1.60 μmol/L. In conclusion, with minimal preparation and quick determination, the method proposed is suitable for measurement of Cu in human breast milk.

  9. Does the prior application of the field kit bullet hole testing kit 3 on a suspected bullet hole bias the analysis of atomic absorption spectrophotometry?

    PubMed

    Seltenhammer, Monika H; Fitzl, Christine; Wieser, Ingo; Binder, Reinhard; Paula, Pia; Risser, Daniele U

    2014-09-01

    Forensic ballistics is the study of bullet trajectory and consists of determining gunshot residue (GSR) to identify bullet holes. Among several highly sensitive methods, atomic absorption spectrophotometry (AAS) is employed to analyze GSR in the laboratory. However, it is sometimes necessary to identify bullet holes immediately at a crime scene. The purpose of this examination was to determine whether the use of the field test Bullet Hole Testing Kit 3 (BTK3) on a suspected bullet hole would influence the outcome of AAS-analysis: Three commonly encountered firearms (Glock17, Tokarev, and Colt) were fired at skin, wood, and cloth. AAS-analysis was performed with and without previous BTK3 application. The results clearly indicate that there is no significant interaction on the grounds of BTK3 use (BTK3 vs. no-BTK3 [kit_nokit] [Pb: p = 0.1309; Sb: p = 0.9111], material*kit_nokit [Pb: p = 0.5960; Sb: p = 0.9930], distance*kit_nokit [Pb: p = 0.4014; Sb: p = 0.9184], and firearm type*kit_nokit [Pb: p = 0.9662; Sb: p = 0.9885]); hence, applying this field kit does not falsify later AAS outcomes.

  10. Comparison of Adsorbed Mercury Screening Method With Cold-Vapor Atomic Absorption Spectrophotometry for Determination of Mercury in Soil

    NASA Technical Reports Server (NTRS)

    Easterling, Donald F.; Hovanitz, Edward S.; Street, Kenneth W.

    2000-01-01

    A field screening method for the determination of elemental mercury in environmental soil samples involves the thermal desorption of the mercury from the sample onto gold and then the thermal desorption from the gold to a gold-film mercury vapor analyzer. This field screening method contains a large number of conditions that could be optimized for the various types of soils encountered. In this study, the conditions were optimized for the determination of mercury in silty clay materials, and the results were comparable to the cold-vapor atomic absorption spectrophotometric method of determination. This paper discusses the benefits and disadvantages of employing the field screening method and provides the sequence of conditions that must be optimized to employ this method of determination on other soil types.

  11. Low-volume, high-sensitivity assay for cadmium in blood and urine using conventional atomic absorption spectrophotometry.

    SciTech Connect

    Cerny, E. A.; Bhattacharyya, M. H.; Biosciences Division

    2003-03-15

    An assay for cadmium in whole blood and urine using deuterium background-correction electrothermal atomic absorption spectroscopy (D2-ETAAS) was developed. Cadmium (in a 1- to 2-ml sample) was bound to 15 mg anion-exchange resin, interfering ions were removed in a 2-ml Bio-Spin column, and cadmium was extracted into 100 {mu}l 1 M nitric acid for analysis. Cadmium in the sample extract was concentrated 7-fold for blood and 10-fold for urine over the starting material. These steps produced cadmium atomic absorption traces with high signal to background ratios and allowed analysis against aqueous standards. At {approx}0.1 ng Cd/ml, mean intra- and interassay coefficients of variation were 11-12%. Cadmium recovery for 0.1 to 0.6 ng added cadmium was 107{+-}4% for blood and 94{+-}4% for urine (mean{+-}SE, n=3). The mean detection limit (mean + 3x SD of blank) was 0.008 ng/ml for blood and 0.003 ng/ml for urine. Samples from 'unexposed' animals including humans ranged from 0.051{+-}0.000 to 0.229{+-}0.035 ng/ml. Values were approximately 10-fold lower than those obtained by the method of Stoeppler and Brandt using Zeeman background-correction ETAAS. This new high-sensitivity, low-volume assay will be useful for epidemiological studies, even those involving children, and will provide a means to help determine the contribution of cadmium to disease incidence in the general population.

  12. Determination of boron in silicon-doped gallium arsenide by electrothermal atomic absorption spectrometry and ultraviolet-visible spectrophotometry.

    PubMed

    Taddia, Marco; Cerroni, Maria Grazia; Morelli, Elio; Musiani, Andrea

    2002-01-01

    Two methods have been developed for the determination of boron impurities in silicon-doped gallium arsenide (GaAs) for electronics. The first method employs the electrothermal atomic absorption spectrometry (ETAAS), the second, the UV-Vis molecular absorption spectrophotomety. In both cases the GaAs sample is decomposed with aqua regia (1+1). To prevent Ga(III) interference on the ETAAS determination of boron, a double extraction of the chlorogallic acid (HGaCl4) in diethyl ether is performed. To improve the overall ETAAS performance, the graphite tubes were pre-treated with iridium(III) and tungsten(IV). A mixed chemical modifier containing Ni(II), Sr(II) and citric acid was also used. The characteristic mass (m0) is 301 +/- 47 pg and the detection limit (3sB) is 2.4 microg g(-1). The classic UV-Vis spectrophotometric procedure using curcumin was also extended to the determination of boron in GaAs. By masking Ga(III) with EDTA and a preliminary extraction of boron with 2-ethyl-hexane 1,3-diol, performed on a semi-micro scale, a detection limit of 0.6 microg g(-1) was achieved. Both methods were applied to the analysis of two Si-doped GaAs samples which were suspected of being boron-contaminated. Results are compared with those obtained by direct analysis of the decomposed sample solution using the inductively coupled plasma atomic emission spectrometry (ICP-AES).

  13. Determination of total tin in geological materials by electrothermal atomic-absorption spectrophotometry using a tungsten-impregnated graphite furnace

    USGS Publications Warehouse

    Zhou, L.; Chao, T.T.; Meier, A.L.

    1984-01-01

    An electrothermal atomic-absorption spectrophotometric method is described for the determination of total tin in geological materials, with use of a tungsten-impregnated graphite furnace. The sample is decomposed by fusion with lithium metaborate and the melt is dissolved in 10% hydrochloric acid. Tin is then extracted into trioctylphosphine oxide-methyl isobutyl ketone prior to atomization. Impregnation of the furnace with a sodium tungstate solution increases the sensitivity of the determination and improves the precision of the results. The limits of determination are 0.5-20 ppm of tin in the sample. Higher tin values can be determined by dilution of the extract. Replicate analyses of eighteen geological reference samples with diverse matrices gave relative standard deviations ranging from 2.0 to 10.8% with an average of 4.6%. Average tin values for reference samples were in general agreement with, but more precise than, those reported by others. Apparent recoveries of tin added to various samples ranged from 95 to 111% with an average of 102%. ?? 1984.

  14. Methods of analysis by the U.S. Geological Survey National Water Quality Laboratory; determination of low-level silver by graphite furnace atomic absorption spectrophotometry

    USGS Publications Warehouse

    Damrau, D.L.

    1993-01-01

    Increased awareness of the quality of water in the United States has led to the development of a method for determining low levels (0.2-5.0 microg/L) of silver in water samples. Use of graphite furnace atomic absorption spectrophotometry provides a sensitive, precise, and accurate method for determining low-level silver in samples of low ionic-strength water, precipitation water, and natural water. The minimum detection limit determined for low-level silver is 0.2 microg/L. Precision data were collected on natural-water samples and SRWS (Standard Reference Water Samples). The overall percent relative standard deviation for natural-water samples with silver concentrations more than 0.2 microg/L was less than 40 percent throughout the analytical range. For the SRWS with concentrations more than 0.2 microg/L, the overall percent relative standard deviation was less than 25 percent throughout the analytical range. The accuracy of the results was determined by spiking 6 natural-water samples with different known concentrations of the silver standard. The recoveries ranged from 61 to 119 percent at the 0.5-microg/L spike level. At the 1.25-microg/L spike level, the recoveries ranged from 92 to 106 percent. For the high spike level at 3.0 microg/L, the recoveries ranged from 65 to 113 percent. The measured concentrations of silver obtained from known samples were within the Branch of Quality Assurance accepted limits of 1 1/2 standard deviations on the basis of the SRWS program for Inter-Laboratory studies.

  15. Ultramicro analysis for copper, cadmium, and zinc in human liver tissue by use of atomic absorption spectrophotometry and the heated graphite tube atomizer.

    PubMed

    Evenson, M A; Anderson, C T

    1975-04-01

    We describe a method of analysis for copper, cadmium, and zinc in a 15-mg (wet weight) sample of human liver by atomic absorption spectrophotometry. The sample is digested with nitric acid (1.0 mol/liter), evaporated, and dilute HNO3 (10 mmol/liter) added. The reconstituted acid mixture is injected into the graphite tube atomizer for analysis of Cu and Cd and aspirated into the air--acetylene flame for measurement of Zn. The absorbance for each metal is suppressed with increasing pH. NaNO3, KNO3, KCl, and NaCl (e.g.) quench the Cd absorbance in acid solutions that contain no protein, but not in the presence of protein. Metal ions added to the predigestion human liver sample at 10 percent and 100 percent of the intrinsic metal concentrations were, respectively, 93 percent and 90 percent accounted for analytically in the case of Cu, 98 percent and 102 percent for Zn, and 101 percent and 93 percent for Cd. Analysis of a National Bureau of Standards' Bovine Liver Standard Reference Material yielded results corresponding to 99 percent (Cu), 112 percent (Zn), and 91 percent (Cd) of the mean expected concentrations of these metals. The between-run coefficient of variation for the bovine liver material was 6 percent for Cu, 9 percent for Zn, and 10 percent for Cd. For 16 histologically normal samples of human liver, the mean values were: Cu, 26; Zn, 293; and Cd, 6.0 nanograms of metal per milligram dry weight, in agreement with values published previously. The method can be easily and reliably applied to small samples of liver obtained by closed-needle biopsy.

  16. Measuring Cation Transport by Na,K- and H,K-ATPase in Xenopus Oocytes by Atomic Absorption Spectrophotometry: An Alternative to Radioisotope Assays

    PubMed Central

    Dürr, Katharina L.; Tavraz, Neslihan N.; Spiller, Susan; Friedrich, Thomas

    2013-01-01

    Whereas cation transport by the electrogenic membrane transporter Na+,K+-ATPase can be measured by electrophysiology, the electroneutrally operating gastric H+,K+-ATPase is more difficult to investigate. Many transport assays utilize radioisotopes to achieve a sufficient signal-to-noise ratio, however, the necessary security measures impose severe restrictions regarding human exposure or assay design. Furthermore, ion transport across cell membranes is critically influenced by the membrane potential, which is not straightforwardly controlled in cell culture or in proteoliposome preparations. Here, we make use of the outstanding sensitivity of atomic absorption spectrophotometry (AAS) towards trace amounts of chemical elements to measure Rb+ or Li+ transport by Na+,K+- or gastric H+,K+-ATPase in single cells. Using Xenopus oocytes as expression system, we determine the amount of Rb+ (Li+) transported into the cells by measuring samples of single-oocyte homogenates in an AAS device equipped with a transversely heated graphite atomizer (THGA) furnace, which is loaded from an autosampler. Since the background of unspecific Rb+ uptake into control oocytes or during application of ATPase-specific inhibitors is very small, it is possible to implement complex kinetic assay schemes involving a large number of experimental conditions simultaneously, or to compare the transport capacity and kinetics of site-specifically mutated transporters with high precision. Furthermore, since cation uptake is determined on single cells, the flux experiments can be carried out in combination with two-electrode voltage-clamping (TEVC) to achieve accurate control of the membrane potential and current. This allowed e.g. to quantitatively determine the 3Na+/2K+ transport stoichiometry of the Na+,K+-ATPase and enabled for the first time to investigate the voltage dependence of cation transport by the electroneutrally operating gastric H+,K+-ATPase. In principle, the assay is not limited to K

  17. Nile blue shows its true colors in gas-phase absorption and luminescence ion spectroscopy.

    PubMed

    Stockett, M H; Houmøller, J; Brøndsted Nielsen, S

    2016-09-14

    Nile blue is used extensively in biology as a histological stain and fluorescent probe. Its absorption and emission spectra are strongly solvent dependent, with variations larger than 100 nm. The molecule is charged due to an iminium group, and it is therefore an obvious target for gas-phase ion spectroscopy. Here we report the absorption and emission spectra of the mass-selected bare ions isolated in vacuo, and based on our results we revisit the interpretation of solution-phase spectra. An accelerator mass spectrometer was used for absorption spectroscopy where the absorption is represented by the yield of photofragment ions versus excitation wavelength (action spectroscopy). The luminescence experiments were done with a newly built ion trap setup equipped with an electrospray ion source, and some details on the mass selection technique will be given which have not been described before. In vacuo, the absorption and emission maxima are at 580 ± 10 nm and 628 ± 1 nm. These values are somewhat blue-shifted relative to those obtained in most solvents; however, they are much further to the red than those in some of the most non-polar solvents. Furthermore, the Stokes shift in the gas phase (1300 cm(-1)) is much smaller than that in these non-polar solvents but similar to that in polar ones. An explanation based on charge localization by solvent dipoles, or by counterions in some non-polar solvents, can fully account for these findings. Hence in the case of ions, it is nontrivial to establish intrinsic electronic transition energies from solvatochromic shifts alone. PMID:27634256

  18. Nile blue shows its true colors in gas-phase absorption and luminescence ion spectroscopy.

    PubMed

    Stockett, M H; Houmøller, J; Brøndsted Nielsen, S

    2016-09-14

    Nile blue is used extensively in biology as a histological stain and fluorescent probe. Its absorption and emission spectra are strongly solvent dependent, with variations larger than 100 nm. The molecule is charged due to an iminium group, and it is therefore an obvious target for gas-phase ion spectroscopy. Here we report the absorption and emission spectra of the mass-selected bare ions isolated in vacuo, and based on our results we revisit the interpretation of solution-phase spectra. An accelerator mass spectrometer was used for absorption spectroscopy where the absorption is represented by the yield of photofragment ions versus excitation wavelength (action spectroscopy). The luminescence experiments were done with a newly built ion trap setup equipped with an electrospray ion source, and some details on the mass selection technique will be given which have not been described before. In vacuo, the absorption and emission maxima are at 580 ± 10 nm and 628 ± 1 nm. These values are somewhat blue-shifted relative to those obtained in most solvents; however, they are much further to the red than those in some of the most non-polar solvents. Furthermore, the Stokes shift in the gas phase (1300 cm(-1)) is much smaller than that in these non-polar solvents but similar to that in polar ones. An explanation based on charge localization by solvent dipoles, or by counterions in some non-polar solvents, can fully account for these findings. Hence in the case of ions, it is nontrivial to establish intrinsic electronic transition energies from solvatochromic shifts alone.

  19. Nile blue shows its true colors in gas-phase absorption and luminescence ion spectroscopy

    NASA Astrophysics Data System (ADS)

    Stockett, M. H.; Houmøller, J.; Brøndsted Nielsen, S.

    2016-09-01

    Nile blue is used extensively in biology as a histological stain and fluorescent probe. Its absorption and emission spectra are strongly solvent dependent, with variations larger than 100 nm. The molecule is charged due to an iminium group, and it is therefore an obvious target for gas-phase ion spectroscopy. Here we report the absorption and emission spectra of the mass-selected bare ions isolated in vacuo, and based on our results we revisit the interpretation of solution-phase spectra. An accelerator mass spectrometer was used for absorption spectroscopy where the absorption is represented by the yield of photofragment ions versus excitation wavelength (action spectroscopy). The luminescence experiments were done with a newly built ion trap setup equipped with an electrospray ion source, and some details on the mass selection technique will be given which have not been described before. In vacuo, the absorption and emission maxima are at 580 ± 10 nm and 628 ± 1 nm. These values are somewhat blue-shifted relative to those obtained in most solvents; however, they are much further to the red than those in some of the most non-polar solvents. Furthermore, the Stokes shift in the gas phase (1300 cm-1) is much smaller than that in these non-polar solvents but similar to that in polar ones. An explanation based on charge localization by solvent dipoles, or by counterions in some non-polar solvents, can fully account for these findings. Hence in the case of ions, it is nontrivial to establish intrinsic electronic transition energies from solvatochromic shifts alone.

  20. Determination of trace cadmium in waters by flame atomic absorption spectrophotometry after preconcentration with 1-nitroso-2-naphthol-3,6-disulfonic acid on Ambersorb 572.

    PubMed

    Kendüzler, Erdal; Türker, Ali Rehber

    2005-01-01

    A procedure for the determination of trace amount of cadmium after adsorption of its 1-nitroso-2-naphthol-3,6-disulfonic acid chelate on Ambersorb 572 has been proposed. This chelate is adsorbed on the adsorbent in the pH range 3-8 from large volumes of aqueous solution of water samples with a preconcentration factor of 200. After being sorbed, cadmium was eluted by 5 mL of 2.0 mol L(-1) nitric acid solution and determined directly by flame atomic absorption spectrophotometery (FAAS). The detection limit (3sigma) of cadmium was 0.32 microg L(-1). The precision of the proposed procedure, calculated as the relative standard deviation of recovery in sample solution (100 mL) containing 5 microg of cadmium was satisfactory (1.9%). The adsorption of cadmium onto adsorbent can formally be described by a Langmuir equation with a maximum adsorption capacity of 19.6 mg g(-1) and a binding constant of 6.5 x 10(-3) L mg(-1). Various parameters, such as the effect of pH and the interference of a number of metal ions on the determination of cadmium, have been studied in detail to optimize the conditions for the preconcentration and determination of cadmium in water samples. This procedure was applied to the determination of cadmium in tap and river water samples.

  1. Determination of sub-microgram amounts of selenium in geological materials by atomic-absorption spectrophotometry with electrothermal atomisation after solvent extraction

    USGS Publications Warehouse

    Sanzolone, R.F.; Chao, T.T.

    1981-01-01

    An atomic-absorption spectrophotometric method with electrothermal atomisation has been developed for the determination of selenium in geological materials. The sample is decomposed with a mixture of nitric, perchloric and hydrofluoric acids and heated with hydrochloric acid to reduce selenium to selenium (IV). Selenium is then extracted into toluene from a hydrochloric acid - hydrobromic acid medium containing iron. A few microlitres of the toluene extract are injected into a carbon rod atomiser, using a nickel solution as a matrix modifier. The limits of determination are 0.2-200 p.p.m. of selenium in a geological sample. For concentrations between 0.05 and 0.2 p.p.m., back-extraction of the selenium into dilute hydrochloric acid is employed before atomisation. Selenium values for reference samples obtained by replicate analysis are in general agreement with those reported by other workers, with relative standard deviations ranging from 4.1 to 8.8%. Recoveries of selenium spiked at two levels were 98-108%. Major and trace elements commonly encountered in geological materials do not interfere. Arsenic has a suppressing effect on the selenium signals, but only when its concentration is greater than 1000 p.p.m. Nitric acid interferes seriously with the extraction of selenium and must be removed by evaporation in the sample-digestion step.

  2. Combined spectrophotometry and tensile measurements of human connective tissues: potentials and limitations

    NASA Astrophysics Data System (ADS)

    Ernstberger, Markus; Sichting, Freddy; Baselt, Tobias; Hartmann, Peter; Aust, Gabriela; Hammer, Niels

    2013-06-01

    Strain-dependent transmission data of nine iliotibial tract specimens are determined using a custom-built optical setup with a halogen light source and an industrial norm material testing machine. Polarized light microscopy and hematoxylin-eosin staining indicated that lateral contraction of collagen structures is responsible for total intensity variations during a 20-cycle preconditioning and a 5-cycle tensile test. Tensile force progress is opposite to total transmission progress. Due to dehydration, wavelength-specific radiation intensity shifting is determined during the test, primarily noticeable in a water absorption band between 1400 and 1500 nm. The results show the capability of integrating spectrophotometry technology into biomechanics for determining structural alterations of human collagen due to applied strain. Being more sensitive to drying, spectrophotometry may likely serve as a quality control in stress-strain testing of biological structures.

  3. Combined spectrophotometry and tensile measurements of human connective tissues: potentials and limitations.

    PubMed

    Ernstberger, Markus; Sichting, Freddy; Baselt, Tobias; Hartmann, Peter; Aust, Gabriela; Hammer, Niels

    2013-06-01

    Strain-dependent transmission data of nine iliotibial tract specimens are determined using a custom-built optical setup with a halogen light source and an industrial norm material testing machine. Polarized light microscopy and hematoxylin-eosin staining indicated that lateral contraction of collagen structures is responsible for total intensity variations during a 20-cycle preconditioning and a 5-cycle tensile test. Tensile force progress is opposite to total transmission progress. Due to dehydration, wavelength-specific radiation intensity shifting is determined during the test, primarily noticeable in a water absorption band between 1400 and 1500 nm. The results show the capability of integrating spectrophotometry technology into biomechanics for determining structural alterations of human collagen due to applied strain. Being more sensitive to drying, spectrophotometry may likely serve as a quality control in stress-strain testing of biological structures.

  4. Improved ultraviolet spectrophotometry of serum theophylline.

    PubMed

    Carter, P; Wallace, J E; Blum, K

    1978-02-01

    We present an improved method for ultraviolet spectrophotometry of theophylline in serum. We studied various extraction techniques aimed at eliminating interferences from co-extractable serum constituents. In the resulting modified procedure, 1 ml of serum is required and a salt-solvent pair of ammonium sulfate and chloroform/hexane is used for extraction. The solvent forms the top phase after extraction, the lower phase after back-extraction, thereby permitting easy removal of the appropriate phase from culture tubes. The use of ammonium sulfate coupled with the added specificity of the extraction solvent results in an extract with low background absorption and a well-defined spectrum for the extracted theophylline.

  5. Spectrophotometry: Past and Present

    NASA Astrophysics Data System (ADS)

    Adelman, Saul J.

    2009-01-01

    I describe the rise of optical region spectrophotometry in the 1960's and 1970's when it achieved a status as a major tool in stellar research through its decline and near demise at present. With absolutely calibrated fluxes and Balmer profiles usually of H-gamma, astronomers used model atmospheres predictions to find both the effective temperatures and surface gravities of many stars. Spectrophotometry as I knew it was photometrically calibrated low dispersion spectroscopy with a typical resolution of order 25 A. A typical data set consists of 10 to 15 values covering most of the optical spectral region. The strengths and shortcomings of the rotating grating scanners are discussed. The accomplishments achieved using spectrophotometric data, which were obtained with instruments using photomultipliers, are reviewed. Extensions to other spectral regions are noted and attempts to use observations from space to calibrate the optical region will be discussed. There are two steps to fully calibrate flux data. The first requires the calibration of the fluxes of one or more standard stars against sources calibrated absolutely in a laboratory. The use of Vega as the primary standard has been both a blessing as it is so bright and a curse especially as modeling it correctly requires treating it as a fast rotating star seen nearly pole-on. At best its calibration has errors of about 1%. The other step is to apply extinction corrections for the Earth's atmosphere and then calibrate the fluxes using the fluxes of standard stars. Now the ASTRA Spectrophotometer promises a revitalization of the use and availability of optical flux data. Its design specifications included solutions to the problems of past optical spectrophotometric instruments.

  6. Infrared Spectrophotometry of PHOBOS

    NASA Astrophysics Data System (ADS)

    Rivkin, A. S.; Trilling, D. E.; Plassmann, J. H.; Brown, R. H.; Bell, J. F., III

    1999-09-01

    We have obtained multispectral images of both the leading and trailing sides of Phobos from the IRTF at 10 wavelengths in the 1.65--3.5 mu m region. The observations were made on 26 April 1999 (UT), with the Cold Coronagraph (CoCo) on NSFCAM. The coronagraph effectively removes the scattered light of Mars from our observations. We find no evidence for a 3-mu m absorption feature (indicative of water of hydration) to within 5-10% on either hemisphere. This finding increases the likelihood that the unexpectedly low density of Phobos found by Viking and the Phobos 2 spacecraft is due to macroporosity effects (as suggested by Avanesov et al. Plan. Space Sci. 1991), among others) rather than compositional effects, since the spectral signature of plausible lower-density materials such as hydrated minerals and water ice have not been found. This is similar to the situation for 253 Mathilde, where the NEAR spacecraft encounter found a low density (Yeomans et al. Science 1997) while Rivkin et al. (Icarus 1997) found an anhydrous surface mineralogy, leading to an interpretation that macroporosity effects were important. The work of Murchie and Erard (Icarus 1996), using data from the Phobos 2 spacecraft, showed that Phobos could be separated into different geological units, based on color and morphology. The fresher areas associated with Stickney crater are bluer in color than the ``background'' areas. For comparison with this work, the ``blue'' unit dominates the leading hemisphere, the ``red'' unit the trailing hemisphere. In the 1.65--3.5 mu m region, we find the two hemispheres to have virtually identical spectra. When connected to visible spectra of Phobos (Murchie and Erard, among others), the leading hemisphere has strong similarities to T-class asteroid spectra. The spectrum of the trailing hemisphere resembles mature lunar soils more closely than any asteroid class.

  7. High-Sensitivity Spectrophotometry.

    ERIC Educational Resources Information Center

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  8. Multi-filter spectrophotometry simulations

    NASA Technical Reports Server (NTRS)

    Callaghan, Kim A. S.; Gibson, Brad K.; Hickson, Paul

    1993-01-01

    To complement both the multi-filter observations of quasar environments described in these proceedings, as well as the proposed UBC 2.7 m Liquid Mirror Telescope (LMT) redshift survey, we have initiated a program of simulated multi-filter spectrophotometry. The goal of this work, still very much in progress, is a better quantitative assessment of the multiband technique as a viable mechanism for obtaining useful redshift and morphological class information from large scale multi-filter surveys.

  9. Spectrophotometry of Comet West

    NASA Technical Reports Server (NTRS)

    Ahearn, M. F.; Hanisch, R. J.; Thurber, C. H.

    1980-01-01

    Postperihelion observations of Comet West (1975n = 1976 VI) have been made with a Fourier transform spectrometer at heliocentric distances from 0.57 to 1.68 AU. Measurements were made of the emission bands of C2, CN, C3, CH, and NH2, as well as the emission lines of Na D and forbidden (O I), and the flux in the continuum in nine different bandpasses. Several ratios of the band strengths of CN have been used to determine the two free parameters in the fluorescence equilibrium model of CN of Danks and Arpigny (1973). From the values of the parameters it is inferred that the vibrational transition probability for the ground electronic state is between 0.025 and 0.075 per sec and that the ratio of oscillator strengths between the (0-0) bands of the violet and red systems is between 25 and 30. When corrected for field-of-view effects, NH2 shows no systematic variation in abundance relative to C2 while CH shows a small increase. The cometary continuum is found to be slightly redder than the solar continuum, consistent with results for other bright, dusty comets. The equivalent width of the Delta u = 0 sequence of C2 shows a marked decrease at r(H) = 1.2 AU.

  10. Clinical applications of lightguide diffuse reflectance spectrophotometry in vascular disease

    NASA Astrophysics Data System (ADS)

    Harrison, David K.; Delaney, Colin; Brown, Linda; Newton, David J.; McCollum, Peter T.

    1994-02-01

    There is enormous potential for application of lightguide tissue reflectance spectrophotometry in the diagnosis and treatment of peripheral vascular disease. In the present study, measurements were carried out in 10 such pre-amputation patients to compare the use of micro-lightguide spectrophotometry with the macro-lightguide technique. These preliminary results show excellent agreement between the new, non-invasive micro-lightguide technique and the `gold standard' skin blood flow measurements. This technique could thus provide a more functional, non-invasive assessment of healing potential than skin blood flow measurement.

  11. PRECISION SPECTROPHOTOMETRY AT THE LEVEL OF 0.1%

    SciTech Connect

    Yan Renbin

    2011-11-15

    Accurate relative spectrophotometry is critical for many science applications. Small wavelength-scale residuals in the flux calibration can significantly impact the measurements of weak emission and absorption features in the spectra. Using Sloan Digital Sky Survey data, we demonstrate that the average spectra of carefully selected red-sequence galaxies can be used as a spectroscopic standard to improve the relative spectrophotometry precision to 0.1% on small wavelength scales (from a few to hundreds of Angstroms). We achieve this precision by comparing stacked spectra across tiny redshift intervals. The redshift intervals must be small enough that any systematic stellar population evolution is minimized and is less than the spectrophotometric uncertainty. This purely empirical technique does not require any theoretical knowledge of true galaxy spectra. It can be applied to all large spectroscopic galaxy redshift surveys that sample a large number of galaxies in a uniform population.

  12. Optical imagery and spectrophotometry of CTB 80

    NASA Technical Reports Server (NTRS)

    Hester, J. Jeff; Kulkarni, Shrinivas R.

    1989-01-01

    Narrow-band imagery and spectrophotometry of the central region of CTB 80 are presented. The images show weak forbidden O III and ubiquitous filamentary forbidden S II and H-alpha emission from the extended radio lobes in which the core is embedded. The data indicate that the extended component is shock heated. Balmer line-dominated emission is observed around the perimeter of the core. Assuming that the volume of the radio shell is similar to the volume of the thermal shell, it is found that a magnetic field of about 600 microG and a cosmic-ray proton-to-electron ratio of about 200 are required to explain the pressure and synchrotron volume emissivity in the radio shell. It is suggested that the optical emission form the core of CTB 80 arises behind shocks which are being driven into a magnetized thermal plasma by the confined relativistic wind from PSR 1951+32.

  13. Design, synthesis, and properties of phthalocyanine complexes with main-group elements showing main absorption and fluorescence beyond 1000 nm.

    PubMed

    Furuyama, Taniyuki; Satoh, Koh; Kushiya, Tomofumi; Kobayashi, Nagao

    2014-01-15

    We present a comprehensive description of the unique properties of newly developed phthalocyanines (Pcs) containing main-group elements that absorb and emit in the near-IR region. Group 16 (S, Se, and Te) elements and group 15 (P, As, and Sb) elements were used as peripheral and central (core) substituents. With the introduction of group 16 elements into free-base Pc, a red-shift of the Q-band was observed, as a result of the electron-donating ability of group 16 elements particularly at the α positions. An X-ray crystallographic analysis of α-ArS-, ArSe-, and ArTe-linked free-base Pcs was also successfully performed, and the relationship between structure and optical properties was clarified. When a group 15 element ion was introduced into the center of the Pc ring, the resulting Pcs showed a single Q-band peak beyond 1000 nm (up to 1056 nm in CH2Cl2). In particular, [(ArS)8PcP(OMe)2](+) and [(ArS)8PcAs(OMe)2](+) exhibited a distinct fluorescence in the 960-1400 nm region with moderate quantum yields. The atomic radius of the group 15 element is important for determining the Pc structure, so that this can be controlled by the choice of group 15 elements. Electrochemical data revealed, while MO calculations suggested, that the red-shift of the Q-band is attributable to a decrease of the HOMO-LUMO gap due to significant and moderate stabilization of the LUMO and HOMO, respectively. The effect of peripheral substutuents and a central P(V) ion on the Q-band shift was independently predicted by MO calculations, while the magnitude of the total calculated shift was in good agreement with the experimental observations. The combination of spectral, electrochemical, and theoretical considerations revealed that all of the central group 15 elements, peripheral group 16 elements, and their positions are necessary to shift the Q-band beyond 1000 nm, indicating that the substitution effects of group 15 and 16 elements act synergistically. The Pcs having Q-bands beyond 1000 nm

  14. Design, synthesis, and properties of phthalocyanine complexes with main-group elements showing main absorption and fluorescence beyond 1000 nm.

    PubMed

    Furuyama, Taniyuki; Satoh, Koh; Kushiya, Tomofumi; Kobayashi, Nagao

    2014-01-15

    We present a comprehensive description of the unique properties of newly developed phthalocyanines (Pcs) containing main-group elements that absorb and emit in the near-IR region. Group 16 (S, Se, and Te) elements and group 15 (P, As, and Sb) elements were used as peripheral and central (core) substituents. With the introduction of group 16 elements into free-base Pc, a red-shift of the Q-band was observed, as a result of the electron-donating ability of group 16 elements particularly at the α positions. An X-ray crystallographic analysis of α-ArS-, ArSe-, and ArTe-linked free-base Pcs was also successfully performed, and the relationship between structure and optical properties was clarified. When a group 15 element ion was introduced into the center of the Pc ring, the resulting Pcs showed a single Q-band peak beyond 1000 nm (up to 1056 nm in CH2Cl2). In particular, [(ArS)8PcP(OMe)2](+) and [(ArS)8PcAs(OMe)2](+) exhibited a distinct fluorescence in the 960-1400 nm region with moderate quantum yields. The atomic radius of the group 15 element is important for determining the Pc structure, so that this can be controlled by the choice of group 15 elements. Electrochemical data revealed, while MO calculations suggested, that the red-shift of the Q-band is attributable to a decrease of the HOMO-LUMO gap due to significant and moderate stabilization of the LUMO and HOMO, respectively. The effect of peripheral substutuents and a central P(V) ion on the Q-band shift was independently predicted by MO calculations, while the magnitude of the total calculated shift was in good agreement with the experimental observations. The combination of spectral, electrochemical, and theoretical considerations revealed that all of the central group 15 elements, peripheral group 16 elements, and their positions are necessary to shift the Q-band beyond 1000 nm, indicating that the substitution effects of group 15 and 16 elements act synergistically. The Pcs having Q-bands beyond 1000 nm

  15. Mathematical calculations of iron complex stoichiometry by direct UV-Vis spectrophotometry.

    PubMed

    Filipský, Tomáš; Říha, Michal; Hrdina, Radomír; Vávrová, Kateřina; Mladěnka, Přemysl

    2013-08-01

    The effects of iron-chelating agents on miscellaneous pathologies are currently largely tested. Due to various indications, different properties for chelators are required. A stoichiometry of the complex in relation to pH is one of the crucial factors. Moreover, the published data on the stoichiometry, especially concerning flavonoids, are equivocal. In this study, a new complementary approach was employed for the determination of stoichiometry in 10 iron-chelating agents, including clinically used drugs, by UV-Vis spectrophotometry at relevant pH conditions and compared with the standard Job's method. This study showed that the simple approach based on absorbance at the wavelength of complex absorption maximum was sufficient when the difference between absorption maximum of substance and complex was high. However, in majority of substances this difference was much lower (9-73 nm). The novel complementary approach was able to determine the stoichiometry in all tested cases. The major benefit of this method compared to the standard Job's approach seems to be its capability to reveal a reaction stoichiometry in chelators with moderate affinity to iron. In conclusion, using this complementary method may explain several previous contradictory data and lead to a better understanding of the underlying mechanisms of chelator's action.

  16. Determination of Iron in Milk Powdermicrowave Digestion and Flame Atomicabsorption Spectrophotometry

    NASA Astrophysics Data System (ADS)

    Zhao, Guangyuan; Li, Bo

    To investigate the conditions of microwave digestion for determining Iron in milk powder by flame atomic absorption spectrophotometry(FAAS), the content of iron in milk powder was determined by flame atomic absorption spectrophotometry after the samples were microwavely digested under different conditions. The optimum parameters for microwave digestion were obtained by the orthogonal test at last. The best optimum parameters for microwave digestion was that, the volume of digestion solution was 8mL, the reagent proportion for HNO3 and H2O2 was 4:1, the digestion time was 8min, the digestion pressure was 2.6 Mpa and the digestion power was 1000 W. The content of Iron in assayed milk powder was 0.0560mg/g. Microwave digestion was a time-saving and practical pretreatment of samples.

  17. Neutralization of feline infectious peritonitis virus: preparation of monoclonal antibody that shows cell tropism in neutralizing activity after viral absorption into the cells.

    PubMed

    Kida, K; Hohdatsu, T; Kashimoto-Tokunaga, J; Koyama, H

    2000-01-01

    Feline infectious peritonitis virus (FIPV) infection of feline macro-phages is enhanced by mouse anti-FIPV monoclonal antibody (MAb). This anti-body-dependent enhancement (ADE) of FIPV infection is dependent on mouse MAb subclass, and MAb of IgG2a subclass has a strong ADE activity. Furthermore, MAb showing strong neutralizing activity in Felis catus whole fetus (fcwf-4) cells and Crandell feline kidney (CrFK) cells shows strong enhancing activity in feline macrophages, indicating that the neutralizing epitope and the enhancing epitope are closely related. In this study, we prepared MAb FK50-4 that showed a strong neutralizing activity in feline macrophages, despite the fact that the MAb belonged to the IgG2a subclass. However, MAb FK50-4 did not exhibit neutralizing activity in CrFK cells or fcwf-4 cells, thus showing a very unusual property. MAb FK50-4 recognized FIPV small integral membrane glycoprotein (M protein). Even when feline macrophages were pretreated with MAb FK50-4 prior to FIPV inoculation, this antibody prevented FIPV infection. This reaction disappeared after treatment of FK50-4 with protein A. The neutralizing activity of FK50-4 was also effective on feline macrophages after the cells were inoculated with FIPV. These findings indicated that the FIPV replication mechanism differs between feline macrophages and CrFK/fcwf-4 cells and that a neutralizing epitope that can prevent FIPV infection of feline macrophages after viral absorption is present on M protein.

  18. X-ray Absorption Spectroscopy of Zinc in Airborne Particulate Matter Shows Tire Debris Concentrated in > 0.5 μm Fraction

    NASA Astrophysics Data System (ADS)

    Pingitore, N. E.; Clague, J. W.; Gill, T. E.; Amaya, M. A.; Cahill, T. A.

    2009-12-01

    Using X-ray absorption spectroscopy (XAS), we speciated Zn in size-resolved fractions of particulate matter (PM) from El Paso, Texas. Spectral patterns indicated that Zn in tire debris is the dominant form of Zn in PM coarser than 0.5 μm in aerodynamic diameter. Although concentrated in the > 0.5 μm fraction, a large portion of the tire debris in PM is small enough to penetrate and deposit in the lower respiratory tract. We collected 3 sets of size-resolved samples of airborne particulate matter (PM) over periods of several days to several weeks in November 2008, and April and May 2009. Local PM compositions typically are dominated by anthropogenic input in November and geologic sources in April, and a mixture in May. The collection site is in the urban core of El Paso, TX, contiguous to the University of Texas at El Paso, 0.6 km from Interstate Highway 10, 0.4 km from State Highway 20, and 1 km from Cd. Juarez, Chihuahua, Mexico. The DRUM sampler (Davis Rotating Uniform size-cut Monitor) employs a rotating Lundgren-type impactor, draws 10 l per minute, and deposits PM on plastic strips mounted on rotating drums. The sampler collected and segregated ambient PM into 8 size cuts: 12-5 μm, 5-2.5, 2.5-1.15, 1.15-0.75, 0.75-0.56, 0.56-0.34, 0.34-0.26, and 0.26-0.09. We conducted the X-ray absorption spectroscopy (XAS) experiments at the Stanford Synchrotron Radiation Lightsource on beam line 7-3. Spectra of the 24 samples of PM and numerous model compounds were collected at the Zn K absorption edge in fluorescence mode using a 30-element Ge solid-state detector. The overall spectral patterns from the 3 seasons were similar to one another. But strikingly, each set of 8 XAS spectra displayed an obvious change in the Zn speciation at the 0.56-0.75 μm size cut. We compared the PM spectra to those of our suite of known model compounds and materials. The spectral pattern of the coarser size cuts was quite similar to those of the tires we tested. The Zn in the tires

  19. A Low-Cost Quantitative Absorption Spectrophotometer

    ERIC Educational Resources Information Center

    Albert, Daniel R.; Todt, Michael A.; Davis, H. Floyd

    2012-01-01

    In an effort to make absorption spectrophotometry available to high school chemistry and physics classes, we have designed an inexpensive visible light absorption spectrophotometer. The spectrophotometer was constructed using LEGO blocks, a light emitting diode, optical elements (including a lens), a slide-mounted diffraction grating, and a…

  20. Ultraviolet spectrophotometry of three LINERs

    NASA Technical Reports Server (NTRS)

    Goodrich, R. W.; Keel, W. C.

    1986-01-01

    Three galaxies known to be LINERs were observed spectroscopically in the ultraviolet in an attempt to detect the presumed nonthermal continuum source thought to be the source of photoionization in the nuclei. NGC 4501 was found to be too faint for study with the IUE spectrographs, while NGC 5005 had an extended ultraviolet light profile. Comparison with the optical light profile of NGC 5005 indicates that the ultraviolet source is distributed spatially in the same manner as the optical starlight, probably indicating that the ultraviolet excess is due to a component of hot stars in the nucleus. These stars contribute detectable absorption features longward of 2500 A; together with optical data, the IUE spectra suggest a burst of star formation about 1 billion yr ago, with a lower rate continuing to produce a few OB stars. In NGC 4579, a point source contributing most of the ultraviolet excess is found that is much different than the optical light distribution. Furthermore, the ultraviolet to X-ray spectral index in NGC 4579 is 1.4, compatible with the UV to X-ray indices found for samples of Seyfert galaxies. This provides compelling evidence for the detection of the photoionizing continuum in NGC 4579 and draws the research fields of normal galaxies and active galactic nuclei closer together. The emission-line spectrum of NGC 4579 is compared with calculations from a photoionization code, CLOUDY, and several shock models. The photoionization code is found to give superior results, adding to the increasing weight of evidence that the LINER phenomenon is essentially a scaled-down version of the Seyfert phenomenon.

  1. Surface composition of Mercury from reflectance spectrophotometry

    NASA Technical Reports Server (NTRS)

    Vilas, Faith

    1988-01-01

    The controversies surrounding the existing spectra of Mercury are discussed together with the various implications for interpretations of Mercury's surface composition. Special attention is given to the basic procedure used for reducing reflectance spectrophotometry data, the factors that must be accounted for in the reduction of these data, and the methodology for defining the portion of the surface contributing the greatest amount of light to an individual spectrum. The application of these methodologies to Mercury's spectra is presented.

  2. The nature of C-class asteroids from 3-micron spectrophotometry

    NASA Technical Reports Server (NTRS)

    Feierberg, M. A.; Lebofsky, L. A.; Tholen, D. J.

    1985-01-01

    Narrowband spectrophotometry between 2.3 and 3.5 micrometers is presented for 14 main-belt C asteroids greater than 100 km in diameter. Absorption features at 3 micrometers due to water of hydration are present in the spectra of nine of the asteroids, with intensities ranging from 6 to 23 percent. The other five asteroids have no such absorption greater than 2 percent in intensity. The present C-asteroid population may be fragments of larger parent bodies with anhydrous C3-like cores and hydrated C1I- or C2M-like mantles.

  3. Partitioning of organophosphorus pesticides into phosphatidylcholine small unilamellar vesicles studied by second-derivative spectrophotometry.

    PubMed

    Takegami, Shigehiko; Kitamura, Keisuke; Ohsugi, Mayuko; Ito, Aya; Kitade, Tatsuya

    2015-06-15

    In order to quantitatively examine the lipophilicity of the widely used organophosphorus pesticides (OPs) chlorfenvinphos (CFVP), chlorpyrifos-methyl (CPFM), diazinon (DZN), fenitrothion (FNT), fenthion (FT), isofenphos (IFP), profenofos (PFF) and pyraclofos (PCF), their partition coefficient (Kp) values between phosphatidylcholine (PC) small unilamellar vesicles (SUVs) and water (liposome-water system) were determined by second-derivative spectrophotometry. The second-derivative spectra of these OPs in the presence of PC SUV showed a bathochromic shift according to the increase in PC concentration and distinct derivative isosbestic points, demonstrating the complete elimination of the residual background signal effects that were observed in the absorption spectra. The Kp values were calculated from the second-derivative intensity change induced by addition of PC SUV and obtained with a good precision of R.S.D. below 10%. The Kp values were in the order of CPFM>FT>PFF>PCF>IFP>CFVP>FNT⩾DZN and did not show a linear correlation relationship with the reported partition coefficients obtained using an n-octanol-water system (R(2)=0.530). Also, the results quantitatively clarified the effect of chemical-group substitution in OPs on their lipophilicity. Since the partition coefficient for the liposome-water system is more effective for modeling the quantitative structure-activity relationship than that for the n-octanol-water system, the obtained results are toxicologically important for estimating the accumulation of these OPs in human cell membranes.

  4. Fast spectrophotometry with compressive sensing

    NASA Astrophysics Data System (ADS)

    Starling, David; Storer, Ian

    2015-03-01

    Spectrophotometers and spectrometers have numerous applications in the physical sciences and engineering, resulting in a plethora of designs and requirements. A good spectrophotometer balances the need for high photometric precision, high spectral resolution, high durability and low cost. One way to address these design objectives is to take advantage of modern scanning and detection techniques. A common imaging method that has improved signal acquisition speed and sensitivity in limited signal scenarios is the single pixel camera. Such cameras utilize the sparsity of a signal to sample below the Nyquist rate via a process known as compressive sensing. Here, we show that a single pixel camera using compressive sensing algorithms and a digital micromirror device can replace the common scanning mechanisms found in virtually all spectrophotometers, providing a very low cost solution and improving data acquisition time. We evaluate this single pixel spectrophotometer by studying a variety of samples tested against commercial products. We conclude with an analysis of flame spectra and possible improvements for future designs.

  5. Determination of the dissociation constants of sulfonated azo dyes by capillary zone electrophoresis and spectrophotometry methods.

    PubMed

    Pérez-Urquiza, M; Beltrán, J L

    2001-05-11

    The dissociation constants of 10 sulfonated azo dyes, six of the most common food colours used as additives (Food Yellow 4, Food Yellow 3, Food Red 9, Food Red 7, Food Red 17 and Food Blue 5), and four commonly used as textile dyes (Acid Orange 7, Acid Orange 12, Acid Red 26 and Acid Red 88), have been determined by two different systems, one by using capillary electrophoresis (CE) with diode array detection and the other by using UV-visible absorption spectrophotometry, which has been used as reference method to obtain the pKa values. The pKa values obtained by CE were determined in two ways, first on the basis of the electrophoretic mobilities (calculated from the migration times), and after we propose a new methodology, in which the dissociation constants are determined from the spectra corresponding to the maxima of electrophoretic peaks. The pKa values obtained by using these CE methods have been compared with those obtained by using the spectrophotometric method. The results show that the pKa values obtained by the CE proposed method are in general closer to the reference values than those obtained from the electrophoretic mobilities. Moreover, the proposed method retains the advantages of CE, as the possibility of working with small amounts of sample, despite its purity.

  6. Tunable Diode Laser Heterodyne Spectrophotometry of Ozone

    NASA Technical Reports Server (NTRS)

    Fogal, P. F.; McElroy, C. T.; Goldman, A.; Murcray, D. G.

    1988-01-01

    Tunable diode laser heterodyne spectrophotometry (TDLHS) has been used to make extremely high resolution (less than 0.0005/ cm) solar spectra in the 9.6 micron ozone band. Observations have shown that a signal-to-noise ratio of 95 : 1 (35% of theoretical) for an integration time of 1/8 second can be achieved at a resolution of 0.0005 wavenumbers. The spectral data have been inverted to yield a total column amount of ozone, in good agreement with that. measured at the nearby National Oceanographic and Atmospheric Administration (NOAA) ozone monitoring facility in Boulder, Colorado.

  7. Airborne spectrophotometry of Comet Halley from 5 to 9 microns

    NASA Technical Reports Server (NTRS)

    Campins, H.; Bregman, J. D.; Witteborn, F. C.; Wooden, D. H.; Rank, D. M.; Cohen, M.; Allamandola, Louis J.; Tielens, Alexander G. G. M.

    1986-01-01

    Spectrophotometry from 5 to 9 microns (resolution = 0.02) of comet Halley was obtained from the Kuiper Airborne Observatory on 1985 Dec. 12.1 and 1986 April 8.6 and 10.5 UT. Two spectral features are apparent in all the observations, one from 5.24 to 5.6 microns, and the silicate emission feature which has an onset between 7 and 8 microns. There is no evidence for the 7.5 microns feature observed by the Vega 1 spacecraft; the large difference between the areal coverage viewed from the spacecraft and the airplane may explain the discrepancy. Color temperatures significantly higher than a blackbody indicate that small particles are abundant in the coma. Significant spatial and temporal variations in the spectrum show trends similar to those observed from the ground.

  8. Intestinal absorption of berberine and 8-hydroxy dihydroberberine and their effects on sugar absorption in rat small intestine.

    PubMed

    Wei, Shi-chao; Dong, Su; Xu, Li-jun; Zhang, Chen-yu

    2014-04-01

    The intestinal absorption of berberine (Ber) and its structural modified compound 8-hydroxy dihydroberberine (Hdber) was compared, and their effects on the intestinal absorption of sugar by perfusion experiment were investigated in order to reveal the mechanism of low dose and high activity of Hdber in the treatment of hyperglycemia. The absorption of Hdber and Ber in rat small intestine was measured by in situ perfusion. High performance liquid chromatography (HPLC) was used to determine the concentrations of Hdber and Ber. In situ perfusion method was also used to study the effects of Hdber and Ber on sugar intestinal absorption. Glucose oxidase method and UV spectrophotometry were applied to examine the concentrations of glucose and sucrose in the perfusion fluid. The results showed that the absorption rate of Ber in the small intestine was lower than 10%, but that of Hdber was larger than 70%. Both Hdber and Ber inhibited the absorption of glucose and sucrose at the doses of 10 and 20 μg/mL. However, Hdber presented stronger activity than Ber (P<0.01). It is suggested that Hdber is absorbed easily in rat small intestine and that its inhibitory effect on the absorption of sugar is better than Ber.

  9. Determination of astaxanthin in Haematococcus pluvialis by first-order derivative spectrophotometry.

    PubMed

    Liu, Xiao Juan; Juan, Liu Xiao; Wu, Ying Hua; Hua, Wu Ying; Zhao, Li Chao; Chao, Zhao Li; Xiao, Su Yao; Yao, Xiao Su; Zhou, Ai Mei; Mei, Zhou Ai; Liu, Xin; Xin, Liu

    2011-01-01

    A highly selective, convenient, and precise method, first-order derivative spectrophotometry, was applied for the determination of astaxanthin in Haematococcus pluvialis. Ethyl acetate and ethanol (1:1, v/v) were found to be the best extraction solvent tested due to their high efficiency and low toxicity compared with nine other organic solvents. Astaxanthin coexisting with chlorophyll and beta-carotene was analyzed by first-order derivative spectrophotometry in order to optimize the conditions for the determination of astaxanthin. The results show that when detected at 432 nm, the interfering substances could be eliminated. The dynamic linear range was 2.0-8.0 microg/mL, with a correlation coefficient of 0.9916. The detection threshold was 0.41 microg/mL. The RSD for the determination of astaxanthin was in the range of 0.01-0.06%; the results of recovery test were 98.1-108.0%. The statistical analysis between first-order derivative spectrophotometry and HPLC by T-testing did not exceed their critical values, revealing no significant differences between these two methods. It was proved that first-order derivative spectrophotometry is a rapid and convenient method for the determination of astaxanthin in H. pluvialis that can eliminate the negative effect resulting from the coexistence of astaxanthin with chlorophyll and beta-carotene. PMID:22320081

  10. HST spectrophotometry of accreting white dwarf pulsators

    NASA Astrophysics Data System (ADS)

    Mukadam, Anjum S.; Szkody, Paula; Gaensicke, Boris T.

    2015-01-01

    The discovery of non-radial pulsations in cataclysmic variables has opened a new venue of opportunity to probe the stellar parameters of accreting variable white dwarfs using asteroseismic techniques. A unique model fit to the observed periods of the variable white dwarf can reveal information about the stellar mass, core composition, age, rotation rate, magnetic field strength, and distance. Mode identification is an essential step in determining an unambiguous model fit, that could be achieved by determining optical and ultra-violet pulsation amplitudes. We will be presenting our results on ultra-violet HST observations acquired with contemporaneous ground based optical data for several cataclysmic variables. The HST spectrophotometry also yields the effective temperatures of the accreting white dwarfs, allowing us to improve our present determination of the instability strip for accreting pulsators. We thank NASA for the grant HST-GO12870 that has supported this research.

  11. Spectrophotometry of the shell around AG Carinae

    NASA Technical Reports Server (NTRS)

    Mitra, P. Mila; Dufour, Reginald J.

    1990-01-01

    Spatially-resolved long-slit spectrophotometry are presented for two regions of the shell nebula around the P-Cygni variable star AG Carinae. The spectra cover the 3700-6800 A wavelength range. Emission-line diagnostics are used to derive extinction, electron temperatures, and densities for various positions in the nebula. The chemical abundances and ionization structure are calculated and compared with other types of planetary nebulae and shells around other luminous stars. It is found that the N/O and N/S ratios of Ag Car are high compared to solar neighborhood ISM values. The O/H depletion found for the AG Car shell approaches that found in the condensations of the Eta Car system.

  12. X-ray absorption and resonant inelastic x-ray scattering (RIXS) show the presence of Cr{sup +} at the surface and in the bulk of CrF{sub 2}

    SciTech Connect

    Jiménez-Mier, J.; Olalde-Velasco, P.; Yang, W.-L.; Denlinger, J.

    2015-07-23

    X-Ray absorption and resonant inelastic x-ray scattering (RIXS) spectra of CrF{sub 2} recorded at the chromium L{sub 2,3} are presented. An atomic multiplet crystal field calculation is compared with the experimental data. Experiment and theory are in agreement once the calculation includes three chromium oxidation states, namely Cr{sup +}, Cr{sup 2+}, and Cr{sup 3+}. X-Ray absorption allows a direct determination of the surface oxidation, while the RIXS spectra shows the presence of these three oxidation states in the sample bulk. To give a quantitative interpretation of the RIXS data the effect of the incomming and outgoing photon penetration depth and self-absorption must be considered. For the much simpler case of MnF{sub 2}, with only one metal oxidation state, the measured RIXS spectra relative intensities are found to be proportional to the square of the sample attenuation length.

  13. CVF spectrophotometry of Pluto - Correlation of composition with albedo. [Circularly variable filter

    SciTech Connect

    Marcialis, R.L.; Lebofsky, L.A. Arizona Univ., Tucson )

    1991-02-01

    The present time-resolved, 0.96-2.65-micron spectrophotometry for the Pluto-Charon system indicates night-to-night variations in the depths of the methane absorptions such that the bands' equivalent width is near minimum light. The interpretation of these data in terms of a depletion of methane in dark regions of the planet, relative to bright ones, is consistent with the Buie and Fink (1987) observations. The near-IR spectrum of Pluto seems to be dominated by surface frost. It is suggested that the dark equatorial regions of Pluto are redder than those of moderate albedo. 28 refs.

  14. CVF spectrophotometry of Pluto - Correlation of composition with albedo. [circularly variable filter

    NASA Technical Reports Server (NTRS)

    Marcialis, Robert L.; Lebofsky, Larry A.

    1991-01-01

    The present time-resolved, 0.96-2.65-micron spectrophotometry for the Pluto-Charon system indicates night-to-night variations in the depths of the methane absorptions such that the bands' equivalent width is near minimum light. The interpretation of these data in terms of a depletion of methane in dark regions of the planet, relative to bright ones, is consistent with the Buie and Fink (1987) observations. The near-IR spectrum of Pluto seems to be dominated by surface frost. It is suggested that the dark equatorial regions of Pluto are redder than those of moderate albedo.

  15. Rhenium(I) tricarbonyl polypyridine complexes showing strong absorption of visible light and long-lived triplet excited states as a triplet photosensitizer for triplet-triplet annihilation upconversion.

    PubMed

    Yi, Xiuyu; Zhao, Jianzhang; Wu, Wanhua; Huang, Dandan; Ji, Shaomin; Sun, Jifu

    2012-08-01

    The preparation of rhenium(I) tricarbonyl polypyridine complexes that show a strong absorption of visible light and long-lived triplet excited state and the application of these complexes as triplet photosensitizers for triplet-triplet annihilation (TTA) based upconversion are reported. Imidazole-fused phenanthroline was used as the N^N coordination ligand, on which different aryl groups were attached (Phenyl, Re-0; Coumarin, Re-1 and naphthyl, Re-2). Re-1 shows strong absorption of visible light (ε = 60,800 M(-1) cm(-1) at 473 nm). Both Re-1 and Re-2 show long-lived T(1) states (lifetime, τ(T), is up to 86.0 μs and 64.0 μs, respectively). These properties are in contrast to the weak absorption of visible light and short-lived triplet excited states of the normal rhenium(I) tricarbonyl polypyridine complexes, such as Re-0 (ε = 5100 M(-1) cm(-1) at 439 nm, τ(T) = 2.2 μs). The photophysical properties of the complexes were fully studied with steady state and time-resolved absorption and emission spectroscopes, as well as DFT calculations. The intra-ligand triplet excited state is proposed to be responsible for the exceptionally long-lived T(1) states of Re-1 and Re-2. The Re(I) complexes were used as triplet photosensitizers for TTA based upconversion and an upconversion quantum yield up to 17.0% was observed.

  16. Optical Region Spectrophotometry: Past and Present

    NASA Astrophysics Data System (ADS)

    Adelman, Saul J.

    In the 1960s and 1970s optical region spectrophotometry achieved the status of a major tool in stellar research. New instrumentation, rotating grating scanners using photomultiplier tubes as detectors, and improved absolute calibrations of Vega made this possible. After this period the use of this technique declined to its near demise at present. The use of Vega as the primary standard has been both a blessing as it is so bright and a curse especially as modeling it correctly requires treating it as a fast rotating star seen nearly pole-on. It may be better to use several stars to define any future absolute calibration. With absolutely calibrated fluxes and Balmer profiles, often Hγ, investigators used the predictions of model atmospheres to find both the effective temperatures and the surface gravities of stars. The fluxes were photometrically calibrated low dispersion spectra with a typical resolution of order 25 Å. A typical data set consisted of 10-15 values covering most of the optical spectral region. At present two instrumental projects ACCESS and the ASTRA Spectrophotometer promise, respectively, a new substantially improved absolute calibration of the optical fluxes of several targets and the availability of a considerable amount of well-calibrated optical flux data for use in studies concerned with stellar properties. They jointly promise to revive optical region spectrophotometric studies.

  17. Noninvasive detection of plant nutrient stress using fiber optic spectrophotometry

    NASA Astrophysics Data System (ADS)

    Chen, Jun-Wei; Asundi, Anand K.; Liew, Oi Wah; Boey, William S. L.

    2001-05-01

    In a previous paper, we described the use of fiber optic spectrophotometry as a non-destructive and sensitive method to detect early symptoms of plant nutrient deficiency. We report further developments of our work on Brassica chinensis var parachinensis (Bailey) showing reproducibility of our data collected at a different seasonal period. Plants at the mid-log growth phase were subjected to nutrient stress by transferring them to nitrate- and calcium- deficient nutrient solution in a standing aerated hydroponic system. After tracking changes in leaf reflectance by FOSpectr for nine days, the plants were returned to complete nutrient solution and their recovery was monitored for a further nine days. The responses of nutrient stressed plants were compared with those grown under complete nutrient solution over the 18-day trial period. We also compared the sensitivity of FOSpectr detection against plant growth measurements vis-a-vis average leaf number and leaf width and show that the former method gave an indication of nutrient stress much earlier than the latter. In addition, this work indicated that while normal and nutrient-stressed plants could not be distinguished within the first 7 days by tracking plant growth indicators, stressed plants did show a clear decline in average leaf number and leaf width in later stages of growth even after the plants were returned to complete nutrient solution. The results further reinforce the need for early detection of nutrient stress, as late remedial action could not reverse the loss in plant growth in later stages of plant development.

  18. Voyager absolute far-ultraviolet spectrophotometry of hot stars

    NASA Technical Reports Server (NTRS)

    Holberg, J. B.; Forrester, W. T.; Shemansky, D. E.; Barry, D. C.

    1982-01-01

    Voyager observations in the 912-1200 A spectral region are used to indirectly intercompare absolute stellar spectrophotometry from previous experiments. Measurements of hot stars obtained by the Voyager 1 and 2 ultraviolet spectrometers show considerably higher 912-1200 A continuum fluxes than the recent observations of Brune et al. (1979) and Carruthers et al. (1981). The intercomparisons show all observations in basic agreement near 1200 A. The Carruthers et al. flux measurements are preferred down to 1050 A at which point the Voyager and Brune et al. values are respectively 60% higher and 60% lower. Below 1050 A the diasgreement among the observations becomes very large and the fluxes predicted by model atmospheres have been adopted. The pure hydrogen line-blanketed model atmosphere calculations of Wesemael et al. 1980) in comparison with Voyager observations of HZ 43 are used to adjust the Voyager calibration below 1050 A. This adjusted Voyager calibration, which is in good agreement with current model atmosphere fluxes for both early-type stars and DA white dwarfs, will be used for Voyager astronomical observations.

  19. Moderate resolution spectrophotometry of high redshift quasars

    NASA Technical Reports Server (NTRS)

    Schneider, Donald P.; Schmidt, Maarten; Gunn, James E.

    1991-01-01

    A uniform set of photometry and high signal-to-noise moderate resolution spectroscopy of 33 quasars with redshifts larger than 3.1 is presented. The sample consists of 17 newly discovered quasars (two with redshifts in excess of 4.4) and 16 sources drawn from the literature. The objects in this sample have r magnitudes between 17.4 and 21.4; their luminosities range from -28.8 to -24.9. Three of the 33 objects are broad absorption line quasars. A number of possible high redshift damped Ly-alpha systems were found.

  20. Ultraviolet spectrophotometry of theophylline in plasma in the presence of barbiturates.

    PubMed

    Jatlow, P

    1975-09-01

    Ultraviolet spectrophotometry is widely used for the analysis of theophylline in blood, for purposes of monitoring therapy, and for pharmacokinetic studies. Phenobarbital, a component of common oral theophylline preparations, interferes with assays now in use. The modification of the method of Schack and Waxler [J. Pharmacol. Exp. Ther. 97, 283 (1949)] presented in this paper eliminates barbiturate interference. After solvent extraction and back extraction into NaOH, the pH of the alkaline solution is adjusted from pH 13 to 10 before spectrophotometric measurement. This shifts the barbiturate absorption maximum from 255 to 240 nm, permitting accurate analysis of theophylline, the spectrum of which is unaffected by the pH change.

  1. Ion Exchange Chromatography and Spectrophotometry: An Introductory Undergraduate Laboratory Experiment.

    ERIC Educational Resources Information Center

    Foster, N.; And Others

    1985-01-01

    Describes an experiment in which students use ion exchange chromatography to separate a mixture of chloro complexes of transition metal ions and then use spectrophotometry to define qualitatively the efficiency of the ion exchange columns. Background information, materials needed, and procedures used are included. (JN)

  2. Evolution of Instrumentation for UV-Visible Spectrophotometry. Part I.

    ERIC Educational Resources Information Center

    Altemose, Ines R.

    1986-01-01

    Traces the development of instruments used in spectrophotometry. Discusses how spectrophotometric measurements are made. Describes the color comparator, the filter photometer, and the spectrophotometer. Outlines the evolution of optical systems, including light sources, the monochromator, the photodetector, double-beam optics, and split-beam…

  3. A Computer-aided Learning Exercise in Spectrophotometry.

    ERIC Educational Resources Information Center

    Pamula, Frederick

    1994-01-01

    Discusses the use of a computer simulation program in teaching the concepts of spectrophotometry. Introduces several parts of the program and program usage. Presents an assessment activity to evaluate students' mastery of material. Concludes with the advantages of this approach to the student and to the assessor. (ASK)

  4. Wavelength Anomalies in UV-Vis Spectrophotometry

    NASA Astrophysics Data System (ADS)

    Tellinghuisen, J.

    2012-06-01

    Commercial spectrophotometers are great tools for recording absorption spectra of low-to-moderate resolution and high photometic quality. However, in the case of at least one such instrument, the Shimadzu UV-2101PC (and by assumption, similar Shimadzu models), the wavelength accuracy may not match the photometric accuracy. In fact the wavelength varies with slit width, spectral sampling interval, and even the specified range, with a smoothing algorithm invoked any time the spectrum includes more than 65 sampled wavelengths. This behavior appears not to be documented anywhere, but it has been present for at least 20 years and persists even in the latest software available to run the instrument. The wavelength shifts can be as large as 1 nm, so for applications where wavelength accuracy better than this is important, wavelength calibration must be done with care to ensure that the results are valid for the parameters used to record the target spectra.

  5. Novel ratio difference at coabsorptive point spectrophotometric method for determination of components with wide variation in their absorptivities

    NASA Astrophysics Data System (ADS)

    Saad, Ahmed S.; Abo-Talib, Nisreen F.; El-Ghobashy, Mohamed R.

    2016-01-01

    Different methods have been introduced to enhance selectivity of UV-spectrophotometry thus enabling accurate determination of co-formulated components, however mixtures whose components exhibit wide variation in absorptivities has been an obstacle against application of UV-spectrophotometry. The developed ratio difference at coabsorptive point method (RDC) represents a simple effective solution for the mentioned problem, where the additive property of light absorbance enabled the consideration of the two components as multiples of the lower absorptivity component at certain wavelength (coabsorptive point), at which their total concentration multiples could be determined, whereas the other component was selectively determined by applying the ratio difference method in a single step. Mixture of perindopril arginine (PA) and amlodipine besylate (AM) figures that problem, where the low absorptivity of PA relative to AM hinders selective spectrophotometric determination of PA. The developed method successfully determined both components in the overlapped region of their spectra with accuracy 99.39 ± 1.60 and 100.51 ± 1.21, for PA and AM, respectively. The method was validated as per the USP guidelines and showed no significant difference upon statistical comparison with reported chromatographic method.

  6. Novel ratio difference at coabsorptive point spectrophotometric method for determination of components with wide variation in their absorptivities.

    PubMed

    Saad, Ahmed S; Abo-Talib, Nisreen F; El-Ghobashy, Mohamed R

    2016-01-01

    Different methods have been introduced to enhance selectivity of UV-spectrophotometry thus enabling accurate determination of co-formulated components, however mixtures whose components exhibit wide variation in absorptivities has been an obstacle against application of UV-spectrophotometry. The developed ratio difference at coabsorptive point method (RDC) represents a simple effective solution for the mentioned problem, where the additive property of light absorbance enabled the consideration of the two components as multiples of the lower absorptivity component at certain wavelength (coabsorptive point), at which their total concentration multiples could be determined, whereas the other component was selectively determined by applying the ratio difference method in a single step. Mixture of perindopril arginine (PA) and amlodipine besylate (AM) figures that problem, where the low absorptivity of PA relative to AM hinders selective spectrophotometric determination of PA. The developed method successfully determined both components in the overlapped region of their spectra with accuracy 99.39±1.60 and 100.51±1.21, for PA and AM, respectively. The method was validated as per the USP guidelines and showed no significant difference upon statistical comparison with reported chromatographic method. PMID:26253440

  7. Spatial variability of absorption properties in Lake Balaton, Hungary

    NASA Astrophysics Data System (ADS)

    Riddick, C. A.; Hunter, P. D.; Tyler, A. N.; Vicente, V. M.; Groom, S.; Horváth, H.; Kovacs, A.; Preston, T.; Presing, M.

    2013-12-01

    In order to improve robustness of current remote sensing algorithms for lake monitoring, it is vital to understand the variability of inherent optical properties (IOPs) within a lake. In this study, absorption coefficients were measured in situ at 38 stations in Lake Balaton, Hungary, using a WET Labs AC-S and AC-9 and compared to concurrent absorption measurements by dual beam spectrophotometry in the laboratory. The spatial variability of bulk and chlorophyll-specific absorption coefficients was examined across 5 basins, demonstrating a gradient in total absorption corresponding to the trophic gradient. Our data suggests that sampling conditions had an impact on particulate absorption, affecting the proportion attributed to non-algal particles (aNAP), phytoplankton (aph) or color dissolved organic matter (aCDOM). The specific absorption of phytoplankton (a*ph) spectra showed a distinct peak in the UV portion of the spectra in Basins 3 and 4 (east), which may be due to the presence of phytoplankton photoprotective pigments to compensate for lower CDOM levels in these basins. In contrast to oceans, particulate attenuation (cp) had a weaker relationship to chlorophyll-a (R2=0.15) than to total suspended matter (R2=0.84), particularly the inorganic fraction. Additionally, the relative contribution of particulate scattering (bp) to attenuation was significantly higher in Lake Balaton (up to 85-99%) than that found in previous lacustrine studies. bp also demonstrated a gradient across the lake, where values increased as the water progressed from phytoplankton-dominated to mineral-dominated. These results provide knowledge of the heterogeneity of the IOPs within Lake Balaton, which is to be considered for the future improvement of bio-optical algorithms for constituent retrieval in inland waters.

  8. Optical spectrophotometry of comet Tempel 2 far from the sun

    NASA Technical Reports Server (NTRS)

    Spinrad, H.; Stauffer, J.; Newburn, R. L., Jr.

    1979-01-01

    With the advent of mission planning for spacecraft encounters with comets in the 1980s, the lack of basic data on cometary nuclei has become quite apparent and a real problem. More effort is needed on all comets, with special attention given to probable space flight targets such as Tempel 2. The paper presents medium-spectral-resolution spectrophotometry of P/Tempel 2, made at heliocentric distances of 2.66 and 3.02 AU on two dates in 1978. It is shown that optical spectrophotometry of comet Tempel 2 near 3 AU heliocentric distance places strict limits on its activity, the modeled CN production rate having an upper limit of 6 times 10 to the 21st molecules per sec. The observations of P/Tempel 2 are compatible with a bare nucleus of 1.6 km radius (geometric albedo = 0.15) and somewhat redder than the sun.

  9. "The Show"

    ERIC Educational Resources Information Center

    Gehring, John

    2004-01-01

    For the past 16 years, the blue-collar city of Huntington, West Virginia, has rolled out the red carpet to welcome young wrestlers and their families as old friends. They have come to town chasing the same dream for a spot in what many of them call "The Show". For three days, under the lights of an arena packed with 5,000 fans, the state's best…

  10. Far ultraviolet spectrophotometry of BD +28 4211

    NASA Technical Reports Server (NTRS)

    Cook, Timothy A.; Cash, Webster; Green, James C.

    1991-01-01

    The results are reported of a November 1989 rocket flight which recorded a flux-calibrated spectrum of BD +28 4211 from 912 to 1150 A with 1A resolution. BD +28 4211, an SdO-type star, is commonly used as an ultraviolet calibration source in the IUE wavelength band. The present work extends the useful range of this standard shortward of Lyman-alpha. Since previous experiments show marked disparity, this study can be useful in determining a standard in the 912 to 1216 A band.

  11. Far-ultraviolet spectrophotometry of Spica

    NASA Technical Reports Server (NTRS)

    Cook, Timothy A.; Cash, Webster; Snow, Theodore P.

    1989-01-01

    A spectrum of the star Spica (Alpha Virginis) from 960 to 1270 A was recorded by a rocket-borne spectrograph March 13, 1988. The spectrum, which has 3.4 A resolution, shows a much sharper drop-off in intensity near 1050 A than similar measurements made by the Voyager UVS, but is in good agreement with the spectrum obtained by Brune et al. in a 1977 sounding rocket. The disagreement with Voyager is a factor of 1.5 at 1100 A and grows to a factor of 5.7 at 960 A. This implies that the photometric standards between 912 and 1100 A may need some revision, and that the standard photospheric models for hot stars may err significantly near the Lyman limit.

  12. Occultation Spectrophotometry of Extrasolar Planets with SOFIA

    NASA Technical Reports Server (NTRS)

    Angerhausen, Daniel; Huber, Klaus F.; Mandell, Avi M.; McElwain, Michael W.; Czesla, Stefan; Madhusudhan, Nikku

    2012-01-01

    The NASA/DLR Stratospheric Observatory for Infrared Astronomy (SOFIA), a 2.5- meter infrared telescope on board a Boeing 747-SP, will conduct 0.3 - 1,600 micrometer photometric, spectroscopic, and imaging observations from altitudes as high as 45,000 ft., where the average atmospheric transmission is greater than 80 percent. SOFIA's first light cameras and spectrometers, as well as future generations of instruments, will make important contributions to the characterization of the physical properties of exoplanets. Our analysis shows that optical and near-infrared photometric and spectrophotometric follow-up observations during planetary transits and eclipses will be feasible with SOFIA's instrumentation, in particular the HIPOFLITECAM optical/NIR instruments. The airborne-based platform has unique advantages in comparison to ground- and space-based observatories in this field of research which we will outline here. Furthermore we will present two exemplary science cases, that will be conducted in SOFIA's cycle 1.

  13. [Determination of amorphous iron oxides in soil by hydroxylamine extraction-spectrophotometry].

    PubMed

    Chi, Guang-yu; Zhang, Zhao-wei; Chen, Xin; Shi, Yi

    2008-12-01

    Amorphous iron oxides in soil were determined by hydroxylamine extraction-spectrophotometry. The results showed that hydroxylamrnine extraction eliminates interference of magnetite and the defect of results being on the high side was overcome to a certain degree compared with oxalic acid-oxalic acid ammonium extraction. The hydroxylamine extraction-spectrophotometry for the detection of amorphous iron oxides in soil was highly precise (relative standard deviation was less than 2.0%) and highly reliable (recovery rates ranged from 97.5% to 101.5%). Other advantages of the method were rapidness,simplicity and a shorter chromogenic time. In addition, soil incubated anaerobically at constant temperature under laboratory condition was investigated. The results suggested that iron reduction rates during initiation, rapid reaction and steady phases in the soil samples anaerobic incubation were 0.030-0.053, 0.186-0.333 and 0.015-0.030 g x d(-1) x kg(-1), respectively. Significant relationship between the concentrations of hydroxylamine extraction iron and iron reduction rates during rapid reaction phase in soil incubation (r= 0.9907, p<0.01) indicated that hydroxylamine had a higher degree of selectivity in amorphous iron oxides extraction than oxalic acid-oxalic acid ammonium extraction.

  14. Technical note: comparing von Luschan skin color tiles and modern spectrophotometry for measuring human skin pigmentation.

    PubMed

    Swiatoniowski, Anna K; Quillen, Ellen E; Shriver, Mark D; Jablonski, Nina G

    2013-06-01

    Prior to the introduction of reflectance spectrophotometry into anthropological field research during the 1950s, human skin color was most commonly classified by visual skin color matching using the von Luschan tiles, a set of 36 standardized, opaque glass tiles arranged in a chromatic scale. Our goal was to establish a conversion formula between the tile-based color matching method and modern reflectance spectrophotometry to make historical and contemporary data comparable. Skin pigmentation measurements were taken on the forehead, inner upper arms, and backs of the hands using both the tiles and a spectrophotometer on 246 participants showing a broad range of skin pigmentation. From these data, a second-order polynomial conversion formula was derived by jackknife analysis to estimate melanin index (M-index) based on tile values. This conversion formula provides a means for comparing modern data to von Luschan tile measurements recorded in historical reports. This is particularly important for populations now extinct, extirpated, or admixed for which tile-based measures of skin pigmentation are the only data available.

  15. Comparative study between univariate spectrophotometry and multivariate calibration as analytical tools for quantitation of Benazepril alone and in combination with Amlodipine.

    PubMed

    Farouk, M; Elaziz, Omar Abd; Tawakkol, Shereen M; Hemdan, A; Shehata, Mostafa A

    2014-04-01

    Four simple, accurate, reproducible, and selective methods have been developed and subsequently validated for the determination of Benazepril (BENZ) alone and in combination with Amlodipine (AML) in pharmaceutical dosage form. The first method is pH induced difference spectrophotometry, where BENZ can be measured in presence of AML as it showed maximum absorption at 237nm and 241nm in 0.1N HCl and 0.1N NaOH, respectively, while AML has no wavelength shift in both solvents. The second method is the new Extended Ratio Subtraction Method (EXRSM) coupled to Ratio Subtraction Method (RSM) for determination of both drugs in commercial dosage form. The third and fourth methods are multivariate calibration which include Principal Component Regression (PCR) and Partial Least Squares (PLSs). A detailed validation of the methods was performed following the ICH guidelines and the standard curves were found to be linear in the range of 2-30μg/mL for BENZ in difference and extended ratio subtraction spectrophotometric method, and 5-30 for AML in EXRSM method, with well accepted mean correlation coefficient for each analyte. The intra-day and inter-day precision and accuracy results were well within the acceptable limits.

  16. Probing potassium in the atmosphere of HD 80606b with tunable filter transit spectrophotometry from the Gran Telescopio Canarias

    NASA Astrophysics Data System (ADS)

    Colón, Knicole D.; Ford, Eric B.; Redfield, Seth; Fortney, Jonathan J.; Shabram, Megan; Deeg, Hans J.; Mahadevan, Suvrath

    2012-01-01

    We report observations of HD 80606 using the 10.4-m Gran Telescopio Canarias and the Optical System for Imaging and low Resolution Integrated Spectroscopy (OSIRIS) tunable filter imager. We acquired very high precision, narrow-band photometry in four bandpasses around the K I absorption feature during the 2010 January transit of HD 80606b and during out-of-transit observations conducted in 2010 January and April. We obtained differential photometric precisions of ˜2.08 × 10-4 for the in-transit flux ratio measured at 769.91 nm, which probes the K I line core. We find no significant difference in the in-transit flux ratio between observations at 768.76 and 769.91 nm. Yet, we find a difference of ˜8.09 ± 2.88 × 10-4 between these observations and observations at a longer wavelength that probes the K I wing (777.36 nm). While the presence of red noise in the transit data has a non-negligible effect on the uncertainties in the flux ratio, the 777.36-769.91 nm colour during transit shows no effects from red noise and also indicates a significant colour change, with a mean value of ˜8.99 ± 0.62 × 10-4. This large change in the colour is equivalent to a ˜4.2 per cent change in the apparent planetary radius with wavelength, which is much larger than the atmospheric scaleheight. This implies the observations probed the atmosphere at very low pressures as well as a dramatic change in the pressure at which the slant optical depth reaches unity between ˜770 and 777 nm. We hypothesize that the excess absorption may be due to K I in a high-speed wind being driven from the exoplanet's exosphere. We discuss the viability of this and alternative interpretations, including stellar limb darkening, star-spots and effects from Earth's atmosphere. We strongly encourage follow-up observations of HD 80606b to confirm the signal measured here. Finally, we discuss the future prospects for exoplanet characterization using tunable filter spectrophotometry.

  17. Method for rapidly determining a pulp kappa number using spectrophotometry

    SciTech Connect

    Chai, Xin-Sheng; Zhu, Jun Yong

    2002-01-01

    A system and method for rapidly determining the pulp kappa number through direct measurement of the potassium permanganate concentration in a pulp-permanganate solution using spectrophotometry. Specifically, the present invention uses strong acidification to carry out the pulp-permanganate oxidation reaction in the pulp-permanganate solution to prevent the precipitation of manganese dioxide (MnO.sub.2). Consequently, spectral interference from the precipitated MnO.sub.2 is eliminated and the oxidation reaction becomes dominant. The spectral intensity of the oxidation reaction is then analyzed to determine the pulp kappa number.

  18. Quantitation of heparosan with heparin lyase III and spectrophotometry.

    PubMed

    Huang, Haichan; Zhao, Yingying; Lv, Shencong; Zhong, Weihong; Zhang, Fuming; Linhardt, Robert J

    2014-02-15

    Heparosan is Escherichia coli K5 capsule polysaccharide, which is the key precursor for preparing bioengineered heparin. A rapid and effective quantitative method for detecting heparosan is important in the large-scale production of heparosan. Heparin lyase III (Hep III) effectively catalyzes the heparosan depolymerization, forming unsaturated disaccharides that are measurable using a spectrophotometer at 232 nm. We report a new method for the quantitative detection of heparosan with heparin lyase III and spectrophotometry that is safer and more specific than the traditional carbazole assay. In an optimized detection system, heparosan at a minimum concentration of 0.60 g/L in fermentation broth can be detected.

  19. A sensitive, spatially uniform photodetector for broadband infrared spectrophotometry

    SciTech Connect

    Iglesias, Enrique J.; Smith, Allan W.; Kaplan, Simon G

    2008-05-01

    We describe the design and performance of a liquid helium-cooled As:Si blocked-impurity-band photodetector system intended for spectrophotometry in the thermal infrared (2 to 30 {mu}m) spectral region. The system has been characterized for spectral sensitivity, noise, thermal stability, and spatial uniformity, and optimized for use with a Fourier-transform infrared spectrophotometer source for absolute goniometric reflectance measurements. Its performance is evaluated and compared to more common detector systems used in this spectral region, including room-temperature pyroelectric and liquid-N2-cooled photoconductive devices.

  20. Analysis of siliceous materials and coal by atomic absorption spectrophotometry with fusion for sample decomposition.

    PubMed

    Lau, O W; Lam, L; Luk, S F

    2000-04-28

    The oxalic acid-lithium carbonate-lithium tetraborate (1:1:1) fusion agent proposed previously for cement analysis is applied to determine the composition of various siliceous samples including granite, clay, flyash, sand and silica fume. For samples with silica content higher than 70%, the sample size had to be reduced from 0.10 to 0.01 g and a recovery factor was needed in silica determination to account for the precipitation of silica during acid dissolution. Attempt has also been made to determine the major metallic elements in coal by fusion directly without the ashing procedure, and the results obtained were good. Further, the ash content of coal was proposed to be determined by establishing a relation between the ash content and the sum of the concentrations of four major oxides (i.e. the oxides of Si, Al, Fe and Ca), and the proposed method is accurate and is time saving compared with that determined by direct ashing at 800 degrees C.

  1. Utilization of ion exchanger and spectrophotometry for assaying amoxycillin and flucloxacillin in dosage form.

    PubMed

    Aly, Hisham M; Amin, Alaa S

    2007-06-29

    A simple, rapid, accurate sensitive spectrophotometry procedure for the determination of amoxycillin (Amox) and flucloxacillin (Fluclox) in bulk samples and in dosage forms are developed. The procedure involves the use of sudan III as chromogenic reagent to produce a violet colored ion-pair with an absorption maximum at 566nm. The ion-pair complexes obey Beer's law and are suitable for the quantitative determination of 0.2-22 and 0.4-25microg/ml of Amox, and Fluclox, respectively. The optimization of different experimental conditions is described in which Amox react after 3min at 25+/-1 degrees C, whereas Fluclox take 10min at 60+/-1 degrees C. Tin(IV) antimonite ion exchanger was utilized to separate a mixture of Amox and Fluclox trihydrate. A column chromatographic technique was applied to separation the antibiotics mixture. Column of 0.3mm diameter and bed height of 3cm of the exchanger was used and the frontal elution technique was utilized. The separation factor for Fluclox and Amox was found to be 2.76. Tin(IV) antimonite ion exchanger exhibit promising feature that can be utilized as stationary phase in either HPLC or HPTLC techniques. The procedure described was applied successfully to determine Amox and Fluclox. The obtained results were compared the official methods. The proposed procedure was successfully applied to determine Amox and Fluclox in their pharmaceutical formulations.

  2. Optical and infrared spectrophotometry of the symbiotic system V1016 Cygni

    NASA Technical Reports Server (NTRS)

    Rudy, Richard J.; Rossano, George S.; Cohen, Ross D.; Puetter, R. C.

    1990-01-01

    Spectrophotometry from 0.46 to 1.3 micron of the peculiar emission-line object V1016 Cyg is presented. The optical region displays a weak continuum underlying the rich emission-line spectrum detailed in past studies. The infrared spectrum consists of prominent emission lines of H I, He I, He II, forbidden Ni, O I, and forbidden S III overlying a strong stellar continuum. The latter displays bands at 0.94 micron and 1.13 micron characteristic of a late-type, oxygen-rich giant as well as an absorption at 1.05 micron which is due to VO. The presence of these molecular features indicates a spectral class of M6 or later for the cool secondary. The reddening of the secondary does not appear to be much different from that of the emission lines. Among the infrared emission features is the rarely seen permitted transition of neutral oxygen at 1.1287 micron. Its presence at a strength comparable to O I 8446 A, together with the absence of O I 13164 A, confirms the result of Strafella that the strong O I lines arise primarily from fluorescent excitation by Ly-beta.

  3. Fiber optic spectrophotometry monitoring of plant nutrient deficiency under hydroponic culture conditions

    NASA Astrophysics Data System (ADS)

    Liew, Oi Wah; Boey, William S. L.; Asundi, Anand K.; Chen, Jun-Wei; He, Duo-Min

    1999-05-01

    In this paper, fiber optic spectrophotometry (FOSpectr) was adapted to provide early detection of plant nutrient deficiency by measuring leaf spectral reflectance variation resulting from nutrient stress. Leaf reflectance data were obtained form a local vegetable crop, Brassica chinensis var parachinensis (Bailey), grown in nitrate-nitrogen (N)- and calcium (Ca)- deficient hydroponics nutrient solution. FOSpectr analysis showed significant differences in leaf reflectance within the first four days after subjecting plants to nutrient-deficient media. Recovery of the nutrient-stressed plants could also be detected after transferring them back to complete nutrient solution. In contrast to FOSpectr, plant response to nitrogen and calcium deficiency in terms of reduced growth and tissue elemental levels was slower and less pronounced. Thus, this study demonstrated the feasibility of using FOSpectr methodology as a non-destructive alternative to augment current methods of plant nutrient analysis.

  4. (21) Lutetia spectrophotometry from Rosetta-OSIRIS images and comparison to ground-based observations

    NASA Astrophysics Data System (ADS)

    Magrin, S.; La Forgia, F.; Pajola, M.; Lazzarin, M.; Massironi, M.; Ferri, F.; da Deppo, V.; Barbieri, C.; Sierks, H.; Osiris Team

    2012-06-01

    Here we present some preliminary results on surface variegation found on (21) Lutetia from ROSETTA-OSIRIS images acquired on 2010-07-10. The spectrophotometry obtained by means of the two cameras NAC and WAC (Narrow and Wide Angle Cameras) is consistent with ground based observations, and does not show surface diversity above the data error bars. The blue and UV images (shortward 500 nm) may, however, indicate a variegation of the optical properties of the asteroid surface on the Baetica region (Sierks et al., 2011). We also speculate on the contribution due to different illumination and to different ground properties (composition or, more probably, grain size diversity). In particular a correlation with geologic units independently defined by Massironi et al. (2012) is evident, suggesting that the variegation of the ground optical properties is likely to be real.

  5. Measurement of vascular permeability in spinal cord using Evans Blue spectrophotometry and correction for turbidity.

    PubMed

    Warnick, R E; Fike, J R; Chan, P H; Anderson, D K; Ross, G Y; Gutin, P H

    1995-05-01

    Vascular permeability can be visualized by Evans Blue (EB) extravasation and quantified by spectrophotometry after formamide extraction of the tissue. However, formamide extracts show significant turbidity, which may contribute to the total optical density at the wavelength of measurement (e.g., 620 lambda). We developed a simple method for estimating the component of the total optical density of a dyed specimen contributed by turbidity. Our method, which uses a determination of turbidity made at another point of the light spectrum (740 lambda), was more precise than two other EB quantification techniques. We therefore recommend it for individual correction of formamide extracts of spinal cord specimens. The application of this technique to the brain remains to be determined.

  6. Accurate quantification of two key time points used in the determination of hydroxyl polyaluminum species by ferron timed spectrophotometry.

    PubMed

    Zhang, Jing; Yong, Xiaojing; Zhao, Dongyan; Shi, Qiuyi

    2015-01-01

    The content of mononuclear Al (Ala%) changed with its determination time (ta) under different dosages of Ferron (7-iodo-8-hydroxyquinoline-5-sulfonic acid, [Ferron]), and the change of Ala% with [Ferron] at different ta was systematically investigated for the first time. Thus, the most appropriate ta was found with the optimal [Ferron]. Also, the judgment of the platform (flat or level portion) of the complete reaction on the absorption-time curve determined in the hydroxyl polyaluminum solution by Ferron timed spectrophotometry (Ferron assay) was first digitized. The time point (tb) of complete reaction between the medium polyaluminum (Alb) and Ferron reagent depended on the reaction extent, and time could not be used only to judge. Thus, the tb was accurately determined and reduced to half of original, which improved the experiment efficiency significantly. The Ferron assay was completely optimized.

  7. Spectrophotometry of comets Giacobini-Zinner and Halley

    NASA Technical Reports Server (NTRS)

    Tegler, Stephen C.; O'Dell, C. R.

    1987-01-01

    Optical window spectrophotometry was performed on comets Giacobini-Zinner and Halley over the interval 300-1000 nm. Band and band-sequence fluxes were obtained for the brightest features of OH, CN, NH, and C2, special care having been given to determinations of extinction, instrumental sensitivities, and corrections for Fraunhofer lines. C2 Swan band-sequence flux ratios were determined with unprecedented accuracy and compared with the predictions of the detailed equilibrium models of Krishna Swamy et al. (1977, 1979, 1981, and 1987). It is found that these band sequences do not agree with the predictions, which calls into question the assumptions made in deriving the model, namely resonance fluorescence statistical equilibrium. Suggestions are made as to how to resolve this discrepancy.

  8. Noninvasive hemoglobin oxygenation monitor and computed tomography by NIR spectrophotometry

    NASA Astrophysics Data System (ADS)

    Oda, Ichiro; Ito, Yasunobu; Eda, Hideo; Tamura, Tomomi; Takada, Michinosuke; Abumi, Rentaro; Nagai, Katumi; Nakagawa, Hachiro; Tamura, Masahide

    1991-05-01

    Using a near infrared (NIR) spectrophotometry, a compact instrument for monitoring the hemoglobin (Hb) oxygenation state in human brain was developed. Brian oxygen metabolism was non-invasively studied by simultaneous measurement of oxygenated Hb, deoxygnated Hb and total Hb content in rat and human head. After evaluating our method using anesthetized and artificially ventilated rats, this instrument was applied for clinical use, and was useful for the management of clinical patients. The same method was applied to develope the NIR computed tomography (CT). Human X-ray CT was modified for NIR-CT, and CT images were obtained using the back-projection (BP) method. NIR-CT could measure the oxygenation map of the tissues of anesthetized rats.

  9. Determination of piroxicam in pharmaceutical preparations by ultraviolet direct spectrophotometry, ultraviolet difference spectrophotometry and high performance liquid chromatography

    SciTech Connect

    Hackmann, E.R.M.; Santos Gianotto, E.A. dos; Miritello Santoro, M.I.R. )

    1993-02-01

    Piroxicam in pharmaceutical preparations (capsules (C), tablets (T), oral drops (OD), suppositories (S) and simulated sample (SS)) was determined by UV direct spectrophotometry (UVS) at 333 nm, by UV difference spectrophotometry (UVDS) at 327 nm, and in C and T, by high performance liquid chromatography (HPLC). For UVS, Beer's law was obeyed in the range 3.0-8.5 [mu]g/mL. The coefficient of correlation (CC), absolute precision (AP) and relative precision (RP) were 0.9999, 0.02 and 0.33%, respectively. The coefficient of variation (CV) for C, T, OD, S and SS were 0.48%, 0.35%, 0.48% and 0.19%, respectively. The recovery average (RA) was 100.22%. For UVDS, Beer's law was obeyed in the range 5.0-15.0 [mu]g/mL. The CC, AP and RP were respectively 0.9999, 0.05 and 0.47%. The CV for C, T, OD, S and SS were 0.64%, 0.84%, 0.62%, 0.54% and 0.15%, respectively. The RA was 99.02%. In HPLC determination, a LiChrospher[reg sign] 100 RP-18 (5 [mu]m) in LiChroCART[reg sign] 125-4 column at ambient temperature with a mobile phase consisting of methanol: (buffer solution citric acid-dibasic sodium phosphate pH 3.0) (55:45) and UV detection at 254 nm enabled the determination of piroxicam in C and T. The response peak area versus concentration presented linearity in the range 10.0-100.0 [mu]g/mL. The CC, AP and RP were 0.9997, 0.45 and 0.90%, respectively. The CV was 0.51%-0.82% and the RA, 97.13%. 14 refs., 1 fig., 5 tabs.

  10. Complexation of Lactate with Nd(III) and Eu(III) at Variable Temperatures: Studies by Potentiometry, Microcalorimetry, Optical Absorption and Luminescence Spectroscopy

    SciTech Connect

    Tian, Guoxin; Martin, Leigh R.; Rao, Linfeng

    2010-10-01

    Complexation of neodymium(III) and europium(III) with lactate was studied at variable temperatures by potentiometry, absorption spectrophotometry, luminescence spectroscopy and microcalorimetry. Stability constants of three successive lactate complexes (ML{sup 2+}, ML{sup 2+} and ML{sub 3}(aq), where M stands for Nd and Eu, and L stands for lactate) at 10, 25, 40, 55 and 70 C were determined. The enthalpies of complexation at 25 C were determined by microcalorimetry. Thermodynamic data show that the complexation of trivalent lanthanides (Nd{sup 3+} and Eu{sup 3+}) with lactate is exothermic, and the complexation becomes weaker at higher temperatures. Results from optical absorption and luminescence spectroscopy suggest that the complexes are inner-sphere chelate complexes in which the protonated {alpha}-hydroxyl group of lactate participates in the complexation.

  11. Complexation of lactate with neodymium(III) and europium(III) at variable temperatures: studies by potentiometry, microcalorimetry, optical absorption, and luminescence spectroscopy.

    PubMed

    Tian, Guoxin; Martin, Leigh R; Rao, Linfeng

    2010-11-15

    The complexation of neodymium(III) and europium(III) with lactate was studied at variable temperatures by potentiometry, absorption spectrophotometry, luminescence spectroscopy, and microcalorimetry. The stability constants of three successive lactate complexes (ML(2+), ML(2)(+), and ML(3)(aq), where M stands for Nd and Eu and L stands for lactate) at 10, 25, 40, 55, and 70 °C were determined. The enthalpies of complexation at 25 °C were determined by microcalorimetry. Thermodynamic data show that the complexation of trivalent lanthanides (Nd(3+) and Eu(3+)) with lactate is exothermic and the complexation becomes weaker at higher temperatures. Results from optical absorption and luminescence spectroscopy suggest that the complexes are inner-sphere chelate complexes in which the protonated α-hydroxyl group of lactate participates in the complexation.

  12. Airborne 20-65 micron spectrophotometry of Comet Halley

    NASA Technical Reports Server (NTRS)

    Glaccum, William; Moseley, S. H.; Campins, Humberto C.; Loewenstein, R. F.

    1988-01-01

    Observations of Comet Halley with a grating spectrometer on board the Kuiper Airborne Observatory on four nights in Dec. 1985 to Apr. 1986 are reported. Low resolution 20 to 65 micrometer spectra of the nucleus with a 40 arcsec FWHM beam was obtained on 17 Dec. 1985, and on 15 and 17 Apr. 1986. On 20 Dec. 1985, only a 20 to 35 micrometer spectrum was obtained. Most of the data have been discussed in a paper where the continuum was dealt with. In that paper, models were fit to the continuum that showed that more micron sized particles of grain similar to amorphous carbon were needed to fit the spectrum than were allowed by the Vega SP-2 mass distribution, or that a fraction of the grains had to be made out of a material whose absorption efficiency fell steeper than lambda sup -1 for lambda greater than 20 micrometers. Spectra was also presented taken at several points on the coma on 15 Apr. which showed that the overall shape to the spectrum is the same in the coma. Tabulated values of the data and calibration curves are available. The spectral features are discussed.

  13. Magnetic resonance cell-tracking studies: spectrophotometry-based method for the quantification of cellular iron content after loading with superparamagnetic iron oxide nanoparticles.

    PubMed

    Böhm, Ingrid

    2011-08-01

    The purpose of this article is to present a user-friendly tool for quantifying the iron content of superparamagnetic labeled cells before cell tracking by magnetic resonance imaging (MRI). Iron quantification was evaluated by using Prussian blue staining and spectrophotometry. White blood cells were labeled with superparamagnetic iron oxide (SPIO) nanoparticles. Labeling was confirmed by light microscopy. Subsequently, the cells were embedded in a phantom and scanned on a 3 T magnetic resonance tomography (MRT) whole-body system. Mean peak wavelengths λ(peak) was determined at A(720 nm) (range 719-722 nm). Linearity was proven for the measuring range 0.5 to 10 μg Fe/mL (r  =  .9958; p  =  2.2 × 10(-12)). The limit of detection was 0.01 μg Fe/mL (0.1785 mM), and the limit of quantification was 0.04 μg Fe/mL (0.714 mM). Accuracy was demonstrated by comparison with atomic absorption spectrometry. Precision and robustness were also proven. On T(2)-weighted images, signal intensity varied according to the iron concentration of SPIO-labeled cells. Absorption spectrophotometry is both a highly sensitive and user-friendly technique that is feasible for quantifying the iron content of magnetically labeled cells. The presented data suggest that spectrophotometry is a promising tool for promoting the implementation of magnetic resonance-based cell tracking in routine clinical applications (from bench to bedside).

  14. The expected performance of stellar parametrization with Gaia spectrophotometry

    NASA Astrophysics Data System (ADS)

    Liu, C.; Bailer-Jones, C. A. L.; Sordo, R.; Vallenari, A.; Borrachero, R.; Luri, X.; Sartoretti, P.

    2012-11-01

    Gaia will obtain astrometry and spectrophotometry for essentially all sources in the sky down to a broad-band magnitude limit of G = 20, an expected yield of 109 stars. Its main scientific objective is to reveal the formation and evolution of our Galaxy through chemodynamical analysis. In addition to inferring positions, parallaxes and proper motions from the astrometry, we must also infer the astrophysical parameters of the stars from the spectrophotometry, the blue photometer (BP)/red photometer (RP) spectrum. Here we investigate the performance of three different algorithms [Support Vector Machine (SVM), ILIUM and Aeneas] for estimating the effective temperature, line-of-sight interstellar extinction, metallicity and surface gravity of A-M stars over a wide range of these parameters and over the full magnitude range Gaia will observe (G = 6-20 mag). One of the algorithms, Aeneas, infers the posterior probability density function over all parameters, and can optionally take into account the parallax and the Hertzsprung-Russell diagram to improve the estimates. For all algorithms the accuracy of estimation depends on G and on the value of the parameters themselves, so a broad summary of performance is only approximate. For stars at G = 15 with less than 2 mag extinction, we expect to be able to estimate Teff to within 1 per cent, log g to 0.1-0.2 dex and [Fe/H] (for FGKM stars) to 0.1-0.2 dex, just using the BP/RP spectrum (mean absolute error statistics are quoted). Performance degrades at larger extinctions, but not always by a large amount. Extinction can be estimated to an accuracy of 0.05-0.2 mag for stars across the full parameter range with a priori unknown extinction between 0 and 10 mag. Performance degrades at fainter magnitudes, but even at G = 19 we can estimate log g to better than 0.2 dex for all spectral types and [ Fe /H] to within 0.35 dex for FGKM stars, for extinctions below 1 mag.

  15. View from My Classroom: A Spectrophotometry Unit for Advanced Chemistry Students.

    ERIC Educational Resources Information Center

    Diehl-Jones, Susan M.

    1983-01-01

    Rationale, objectives, and instructional strategies for a directed study course on spectrophotometry are provided. Descriptions of three experiments and four student research projects are also provided. Objectives, laboratory procedures, advantages, and disadvantages for the experiments and projects are included. (JN)

  16. Spectrophotometry of Pluto from 3500 to 7350 A

    SciTech Connect

    Barker, E.S.; Cochran, W.D.; Cochran, A.L.

    1980-01-01

    Spectra of Pluto have been obtained on six nights during February 1979 by the use of the Cassegrain Digicon spectrograph on the 2.1-m Struve reflector and the IDS spectrograph on the 2.7-m reflector of McDonald Observatory. These spectra, with nominal resolution of 6-7 A, have been reduced to relative fluxes. Relative albedos were then calculated using the solar irradiances of Arvesen et al. (1969). The spectra taken in the blue show no indication of the upturn in albedo at wavelengths less than 3800 A previously reported by Fix, et al. (1970). The lack of a UV upturn cannot be interpreted in terms of a Rayleigh scattering atmosphere unless the albedo of the underlying surface is known. From the lack of methane absorption at the wavelength of the 6190- or 7270-A methane bands, an upper limit of 1-3 m-am of gaseous CH4 is derived. The albedo curve has a constant slope between 3500 and 7300 A. The only other solar system body which has this feature is an S-type asteroid.

  17. Spectrophotometry of Wolf-Rayet stars. I - Continuum energy distributions

    NASA Technical Reports Server (NTRS)

    Morris, Patrick W.; Brownsberger, Kenneth R.; Conti, Peter S.; Massey, Philip; Vacca, William D.

    1993-01-01

    All available low-resolution IUE spectra are assembled for Galactic, LMC, and SMC W-R stars and are merged with ground-based optical and NIR spectra in order to collate in a systematic fashion the shapes of these energy distributions over the wavelength range 0.1-1 micron. They can be consistently fitted by a power law of the form F(lambda) is approximately equal to lambda exp -alpha over the range 1500-9000 A to derive color excesses E(B-V) and spectral indices by removing the 2175-A interstellar absorption feature. The WN star color excesses derived are found to be in good agreement with those of Schmutz and Vacca (1991) and Koesterke et al. (1991). Significant heterogeneity in spectral index values was generally seen with any given subtype, but the groups consisting of the combined set of Galactic and LMC W-R stars, the separate WN and WC sequences, and the Galactic and LMC W-R stars all showed a striking and consistent Gaussian-like frequency distribution of values.

  18. Aluminum complexation by catechol as determined by ultraviolet spectrophotometry

    SciTech Connect

    Sikora, F.J.; McBride, M.B.

    1989-03-01

    Methods of ultraviolet (UV) spectrophotometry were used to determine the stoichiometry and association constant for the Al-catechol complex from pH 3.8 to 4.6. Job's method of continuous variation indicated the Al-catechol complex had a 1:1 stoichiometry in the pH range studied. Aluminum titrations of catechol and pH titrations of catechol plus Al resulted in a shift in the UV spectra due to the formation of an Al-catechol complex absorbing UV radiation uniquely different than that of free catechol. General equations were developed for the determination of association constants assuming an organic and Al-organic complex absorb UV radiation. Aluminum titrations with constant catechol concentration yielded a log k/sub 0.1//sup c/ of 16.22 for a 1:1 Al-catechol complex. Calculated absorbance as a function of pH agree dwell with experimental pH titrations of solutions containing catechol plus Al. The fact that Al can be complexed by catechol at low pH indicates the o-hydroxy group provides a potential source for Al complexation in soil and surface waters.

  19. HUBBLE SPACE TELESCOPE SPECTROPHOTOMETRY AND MODELS FOR SOLAR ANALOGS

    SciTech Connect

    Bohlin, R. C.

    2010-04-15

    Absolute flux distributions for seven solar analog stars are measured from 0.3 to 2.5 {mu}m by Hubble Space Telescope (HST) spectrophotometry. In order to predict the longer wavelength mid-IR fluxes that are required for James Webb Space Telescope calibration, the HST spectral energy distributions are fit with Castelli and Kurucz model atmospheres; and the results are compared with fits from the MARCS model grid. The rms residuals in 10 broadband bins are all <0.5% for the best fits from both model grids. However, the fits differ systematically: the MARCS fits are 40-100 K hotter in T {sub eff}, 0.25-0.80 higher in log g, 0.01-0.10 higher in log z, and 0.008-0.021 higher in the reddening E(B - V), probably because their specifications include different metal abundances. Despite these differences in the parameters of the fits, the predicted mid-IR fluxes differ by only {approx}1%; and the modeled flux distributions of these G stars have an estimated ensemble accuracy of 2% out to 30 {mu}m.

  20. Acoustic Absorption Characteristics of People.

    ERIC Educational Resources Information Center

    Kingsbury, H. F.; Wallace, W. J.

    1968-01-01

    The acoustic absorption characteristics of informally dressed college students in typical classroom seating are shown to differ substantially from data for formally dressed audiences in upholstered seating. Absorption data, expressed as sabins per person or absorption coefficient per square foot, shows that there is considerable variation between…

  1. Spectrophotometry of (32) Pomona, (145) Adeona, (704) Interamnia, (779) Nina, (330825) 2008 XE3, and 2012 QG42 and laboratory study of possible analog samples

    NASA Astrophysics Data System (ADS)

    Busarev, Vladimir V.; Barabanov, Sergey I.; Rusakov, Vyacheslav S.; Puzin, Vasiliy B.; Kravtsov, Valery V.

    2015-12-01

    Six asteroids including two NEAs, one of which is PHA, accessible for observation in September 2012 were investigated using a low-resolution (R ≈ 100) spectrophotometry in the range 0.35-0.90 μm with the aim to study features of their reflectance spectra. A high-altitude position of our Terskol Observatory (3150 m above sea level) favorable for the near-UV and visible-range observations of celestial objects allowed us to probably detect some new spectral features of the asteroids. Two subtle absorption bands centered at 0.53 and 0.74 μm were found in the reflectance spectra of S-type (32) Pomona and interpreted as signs of presence of pyroxenes in the asteroid surface matter and its different oxidation. Very similar absorption bands centered at 0.38, 0.44 and 0.67-0.71 μm have been registered in the reflectance spectra of (145) Adeona, (704) Interamnia, and (779) Nina of primitive types. We performed laboratory investigations of ground samples of known carbonaceous chondrites, Orguel (CI), Mighei (CM2), Murchison (CM2), Boriskino (CM2), and seven samples of low-iron Mg serpentines as possible analogs of the primitive asteroids. In the course of this work, we discovered an intense absorption band (up to ∼25%) centered at 0.44 μm in reflectance spectra of the low-Fe serpentine samples. As it turned out, the equivalent width of the band has a high correlation with content of Fe3+ (octahedral and tetrahedral) in the samples. It may be considered as a confirmation of the previously proposed mechanism of the absorption due to electronic transitions in exchange-coupled pairs (ECP) of Fe3+ neighboring cations. It means that the absorption feature can be used as an indicator of ferric iron in oxidized and hydrated low-Fe compounds on the surface of asteroids and other atmosphereless celestial bodies. Moreover, our measurements showed that the mechanism of light absorption is partially or completely blocked in the case of intermediate to high iron contents. Therefore

  2. [Usefulness of one point measurement method of pediatric dose and UV spectrophotometry for filterability test of in-line filter].

    PubMed

    Yamanouchi, Tsuneaki; Horiuchi, Kenichi; Ishii, Kazunari; Mimura, Yasuhiko; Kato, Atsushi; Adachi, Isao

    2014-01-01

    The adsorption of Bevacizumab, Trastuzumab, Rituximab, Nedaplatin, Vincristine sulfate, Nogitecan hydrochloride, Actinomycin D and Ramosetron hydrochloride to 0.2 μm endotoxin-retentive in-line filters was evaluated with pediatric doses by UV spectrophotometry. The results indicated that some drug adsorption was shown with Nogitecan hydrochloride, Actinomycin D and Ramosetron hydrochloride, and good recovery was shown with the other five drugs. For the three drugs which showed some losses, drug recovery was investigated at multiple test doses. The approximation formula for each drug adsorption was recorded as Y=100-A/X (X: dose (mg), Y: recovery rate (%), A: a constant for individual drug). The results showed there was high correlation between the reciprocal of test drug dose and the recovery rate. Furthermore, in the cases where adsorption to the filter were observed, it was found that it was possible to determine the relationship between dose and the recovery rate from a filterability test with one point pediatric dose. Since the recovery rate obtained from the approximation formula with multiple doses and that calculated from the prediction formula with one point pediatric dose were almost the same, then it was concluded that it is not necessary to conduct the filterability tests with multiple doses. We have shown that using UV spectrophotometry and carrying out a filterability test using one point pediatric dose is relatively easy method and reduces the effort and expense. This method for analysis of drug adsorption is extremely useful when using in-line filters with infusion therapy.

  3. Band gap states in nanocrystalline WO3 thin films studied by soft x-ray spectroscopy and optical spectrophotometry.

    PubMed

    Johansson, M B; Kristiansen, P T; Duda, L; Niklasson, G A; Österlund, L

    2016-11-30

    Nanocrystalline tungsten trioxide (WO3) thin films prepared by DC magnetron sputtering have been studied using soft x-ray spectroscopy and optical spectrophotometry. Resonant inelastic x-ray scattering (RIXS) measurements reveal band gap states in sub-stoichiometric γ-WO3-x with x  =  0.001-0.005. The energy positions of these states are in good agreement with recently reported density functional calculations. The results were compared with optical absorption measurements in the near infrared spectral region. An optical absorption peak at 0.74 eV is assigned to intervalence transfer of polarons between W sites. A less prominent peak at energies between 0.96 and 1.16 eV is assigned to electron excitation of oxygen vacancies. The latter results are supported by RIXS measurements, where an energy loss in this energy range was observed, and this suggests that electron transfer processes involving transitions from oxygen vacancy states can be observed in RIXS. Our results have implications for the interpretation of optical properties of WO3, and the optical transitions close to the band gap, which are important in photocatalytic and photoelectrochemical applications. PMID:27660919

  4. Band gap states in nanocrystalline WO3 thin films studied by soft x-ray spectroscopy and optical spectrophotometry

    NASA Astrophysics Data System (ADS)

    Johansson, M. B.; Kristiansen, P. T.; Duda, L.; Niklasson, G. A.; Österlund, L.

    2016-11-01

    Nanocrystalline tungsten trioxide (WO3) thin films prepared by DC magnetron sputtering have been studied using soft x-ray spectroscopy and optical spectrophotometry. Resonant inelastic x-ray scattering (RIXS) measurements reveal band gap states in sub-stoichiometric γ-WO3-x with x  =  0.001-0.005. The energy positions of these states are in good agreement with recently reported density functional calculations. The results were compared with optical absorption measurements in the near infrared spectral region. An optical absorption peak at 0.74 eV is assigned to intervalence transfer of polarons between W sites. A less prominent peak at energies between 0.96 and 1.16 eV is assigned to electron excitation of oxygen vacancies. The latter results are supported by RIXS measurements, where an energy loss in this energy range was observed, and this suggests that electron transfer processes involving transitions from oxygen vacancy states can be observed in RIXS. Our results have implications for the interpretation of optical properties of WO3, and the optical transitions close to the band gap, which are important in photocatalytic and photoelectrochemical applications.

  5. Band gap states in nanocrystalline WO3 thin films studied by soft x-ray spectroscopy and optical spectrophotometry.

    PubMed

    Johansson, M B; Kristiansen, P T; Duda, L; Niklasson, G A; Österlund, L

    2016-11-30

    Nanocrystalline tungsten trioxide (WO3) thin films prepared by DC magnetron sputtering have been studied using soft x-ray spectroscopy and optical spectrophotometry. Resonant inelastic x-ray scattering (RIXS) measurements reveal band gap states in sub-stoichiometric γ-WO3-x with x  =  0.001-0.005. The energy positions of these states are in good agreement with recently reported density functional calculations. The results were compared with optical absorption measurements in the near infrared spectral region. An optical absorption peak at 0.74 eV is assigned to intervalence transfer of polarons between W sites. A less prominent peak at energies between 0.96 and 1.16 eV is assigned to electron excitation of oxygen vacancies. The latter results are supported by RIXS measurements, where an energy loss in this energy range was observed, and this suggests that electron transfer processes involving transitions from oxygen vacancy states can be observed in RIXS. Our results have implications for the interpretation of optical properties of WO3, and the optical transitions close to the band gap, which are important in photocatalytic and photoelectrochemical applications.

  6. The Uranian satellites and Hyperion - New spectrophotometry and compositional implications

    NASA Technical Reports Server (NTRS)

    Brown, R. H.

    1983-01-01

    New reflectance spectra at 3.5 percent resolution have been obtained for Ariel, Titania, Oberon, and Hyperion in the 0.8 to 1.6-micron spectrum region. The new spectra show no absorptions other than the 1.5 micron water-ice feature (within the precision of the data), and demonstrate extension into the 0.8- to 1.6 micron region of the 1.5- to 2.5 micron spectral similarity ofo Ariel to Hyperion (Brown and Cruikshank, 1983). The new data confirm the presence of a dark, spectrally bland component on/in the water-ice surfaces of the Uranian satellites, which, with some reservations, has spectral similarities to the dark substance on the leading side of lapetus and the dark material on/in the surface of Hyperion, as well as other dark, spectrally neutral substances such as charcoal. Attempts were made to match the spectra of Ariel, Titania, and Oberon with additive reflectance mixes (aeral coverage) of fine-grained water frost and various dark components such as charcoal, lampblack, and charcoal-water-ice mixtures. The results were broad limits on the amounts of possible areal coverage of a charcoal-like spectral component on the surfaces of the Uranian satellites, but the data are not of sufficient precision to conclusively determine whether the dominant mode of contaminant dispersal is areal or voluminal. The effect of highly variegated albedos on the diameters derived by Brown, Cruikshank, and Morrison (1982) is found to be small.

  7. The measurement of tooth whiteness by image analysis and spectrophotometry: a comparison.

    PubMed

    Guan, Y H; Lath, D L; Lilley, T H; Willmot, D R; Marlow, I; Brook, A H

    2005-01-01

    Digital image capturing and analysis techniques have been used to measure the colour of teeth and to compare with spectrophotometric results and visual observations. A non-linear image analysis approach was developed and, for the colour range of human teeth, allows device-dependant digital camera colour data to be quantitatively transformed to Commission Internationale de l'Eclairage (CIE) colorimetric values. With reference to a CIE standard illuminant, two different lighting arrays have been used. For flat and non-translucent white and yellow surfaces, spectrophotometric results showed that this transformation achieves required accuracy. It was found, in all of the present studies, which included measurements on the VITA Lumin Vacuum shade guide and extracted teeth, that spectrophotometry invariably underestimated values of the CIE whiteness index. However, the results from these two types of measurement correlated well. There was also a reasonably good correlation between earlier data obtained by visual assessment and the present data by the two instrumental methods. For extracted teeth, both instrumental methods used in this work did not confirm a whitening effect for 2-min brushing with toothpaste, but did show significant whitening results for bleaching with 15% hydrogen peroxide. PMID:15634295

  8. PHASES: A Project to Perform Absolute Spectrophotometry from Space

    NASA Astrophysics Data System (ADS)

    del Burgo, C.; Vather, D.; Allende Prieto, C.; Murphy, N.

    2013-04-01

    This paper presents the current status of the opto-mechanical design of PHASES (Planet Hunting and AsteroSeismology Explorer Spectrophotometer), which is a project to develop a space-borne telescope to obtain absolute flux calibrated spectra of bright stars. The science payload is intended to be housed in a micro-satellite launched into a low-earth Sun-synchronous orbit with an inclination to the equator of 98.7° and a local time ascending node LTAN of 6:00 AM. PHASES will be able to measure micromagnitude photometric variations due to stellar oscillations/activity and planet/moon transits. It consists of a 20 cm aperture modified Baker telescope feeding two detectors: the tracking detector provides the fine telescope guidance system with a required pointing stability of 0.2″, and the science detector performs spectrophotometry in the wavelength range 370-960 nm with a resolving power between 200 and 900. The spectrograph is designed to provide 1% RMS flux calibrated spectra with signal-to-noise ratios > 100 for stars with V < 10 in short integration times. Our strategy to calibrate the system using A type stars is explained. From comparison with model atmospheres it would be possible to determine the stellar angular diameters with an uncertainty of approximately 0.5%. In the case of a star hosting a transiting planet it would be possible to derive its light curve, and then the planet to stellar radius ratio. Bright stars have high precision Hipparcos parallaxes and the expected level of accuracy for their fluxes will be propagated to the stellar radii, and more significantly to the planetary radii. The scientific drivers for PHASES give rise to some design challenges, which are particularly related to the opto-mechanics for extreme environmental conditions. The optical design has been developed with the primary goal of avoiding stray light reaching the science detector. Three different proposals for the opto-mechanical design are under investigation.

  9. Fast spectrophotometry of the flare star EV lacertae

    NASA Astrophysics Data System (ADS)

    Zhilyaev, B. E.; Andreev, M. V.; Sergeev, A. V.; Reshetnik, V. N.; Parakhin, N. A.

    2012-12-01

    We present the results of fast spectrophotometry for two flares on EV Lac with a time resolution of 8 s and a spectroscopic resolution R ˜ 100. The observations were performed in May and August 2010 with a slitless spectrograph on the Zeiss-600 telescope at Peak Terskol. We have estimated the UBVR magnitudes from spectrograms through a mathematical convolution of the spectra with the filter transmission curves. The UBV R amplitudes of the August 10, 2010 flare are 2\\underset{raise0.3emsmashriptscriptstyle\\cdot}{m} 83, 1\\underset{raise0.3emsmashriptscriptstyle\\cdot}{m} 94, 0\\underset{raise0.3emsmashriptscriptstyle\\cdot}{m} 82, and 0\\underset{raise0.3emsmashriptscriptstyle\\cdot}{m} 28, respectively. The UBV R amplitudes of the May 30, 2010 flare are 0\\underset{raise0.3emsmashriptscriptstyle\\cdot}{m} 65, 0\\underset{raise0.3emsmashriptscriptstyle\\cdot}{m} 25, 0\\underset{raise0.3emsmashriptscriptstyle\\cdot}{m} 15, and 0\\underset{raise0.3emsmashriptscriptstyle\\cdot}{m} 10, respectively. A detailed colorimetric analysis has allowed important parameters of the flares on EV Lac to be estimated: the temperatures at maximum light and their sizes. The color-color ( U - B)-( B - V ) diagrams confirm that both flares at maximum light radiate as a blackbody. The temperatures at maximum light was 13 400 ± 500 K for the August flare and 5700 ± 100 K for the May flare. During the May flare, an additional hydrogen emission appeared in the Balmer H α, H β, H γ, H δ, H ɛ, H ζ lines and the Balmer continuum (3647 Å) in the spectrum of EV Lac. The excess of emission in the Balmer lines was approximately from two to thirty percent. Based on our colorimetric analysis, we have estimated the linear sizes of the flares at maximum light. The size of the May 30, 2010 flare is approximately 7% of the stellar radius. The size of the August 10, 2010 flare is 3.9% of the stellar radius.

  10. Egg colour matching in an African cuckoo, as revealed by ultraviolet-visible reflectance spectrophotometry.

    PubMed

    Cherry, M I; Bennett, A T

    2001-03-22

    Despite major differences between human and avian colour vision, previous studies of cuckoo egg mimicry have used human colour vision (or standards based thereon) to assess colour matching. Using ultraviolet-visible reflectance spectrophotometry (300-700 nm), we measured museum collections of eggs of the red-chested cuckoo and its hosts. The first three principal components explained more than 99% of the variance in spectra, and measures of cuckoo host egg similarity derived from these transformations were compared with measures of cuckoo host egg similarity estimated by human observers unaware of the hypotheses we were testing. Monte Carlo methods were used to simulate laying of cuckoo eggs at random in nests. Results showed that host and cuckoo eggs were very highly matched for an ultraviolet versus greenness component, which was not detected by humans. Furthermore, whereas cuckoo and host were dissimilar in achromatic brightness, humans did not detect this difference. Our study thus reveals aspects of cuckoo-host egg colour matching which have hitherto not been described. These results suggest subtleties and complexities in the evolution of host-cuckoo egg mimicry that were not previously suspected. Our results also have the potential to explain the longstanding paradox that some host species accept cuckoo eggs that are non-mimetic to the human eye.

  11. Determination of attapulgite and nifuroxazide in pharmaceutical formulations by sequential digital derivative spectrophotometry.

    PubMed

    Toral, M Inés; Paine, Maximiliano; Leyton, Patricio; Richter, Pablo

    2004-01-01

    A new method for the sequential determination of attapulgite and nifuroxazide in pharmaceutical formulations by first- and second-derivative spectrophotometry, respectively, has been developed. In order to obtain the optimal conditions for nifuroxazide stability, studies of solvent, light, and temperature effects were performed. The results show that a previous hydrolysis of 2 h in 1.0 x 10(-1)M NaOH solution is necessary in order to obtain stable compounds for analytical purposes. Subsequently, the first- and second-derivative spectra were evaluated directly in the same samples. The sequential determination of the drugs can be performed using the zero-crossing method; the attapulgite determination was carried out using the first derivative at 278.0 nm and the nifuroxazide determination, using the second derivative at 282.0 nm. The determination ranges were 5.7 x 10(-6)-1.0 x 10(-4) and 3.7 x 10(-8) -1.2 x 10(-4)M for attapulgite and nifuroxazide, respectively. Repeatability (relative standard deviation) values of 1.2 and 3.0% were observed for attapulgite and nifuroxazide, respectively. The ingredients commonly found in commercial pharmaceutical formulations do not interfere. The proposed method was applied to the determination of these drugs in tablets. Further, infrared spectroscopy and cyclic voltammetry studies were carried out in order to obtain knowledge of the decomposition products of nifuroxazide. PMID:15675443

  12. Benzo(a)pyrene diolepoxide-DNA adducts detected by synchronous fluorescence spectrophotometry.

    PubMed Central

    Vahakangas, K; Trivers, G; Rowe, M; Harris, C C

    1985-01-01

    Using benzo(a)pyrene (BP) as a model carcinogen we are currently applying a fluorescence technique to detect the very low levels of carcinogen-DNA adducts in human populations due to environmental exposure. In synchronous fluorescence spectrophotometry for detection of BP-diol epoxide-DNA, excitation and emission wavelengths are scanned simultaneously with a fixed wavelength difference (delta lambda) of 34 nm. Compared to conventional fluorescence methods only one peak emerges because excitation and emission peaks have to match delta lambda to show. Because of the quenching effect of DNA, samples are hydrolyzed by acid. After this, BP-diol epoxide (BPDE)- -modified DNA gives a peak at the same wavelength and of the same fluorescence yield as BP-tetrols. When DNA from peripheral blood lymphocytes of 44 coke oven workers were analyzed, 10 had a sharp peak at 379. Among 36 coke oven workers from another factory, 4 had detectable levels of adducts. A much smaller percentage of samples was positive in a group of aluminum plant workers. We have also found BPDE-DNA adducts in DNA from pulmonary alveolar macrophages and peripheral blood lymphocytes from tobacco smokers and some of the nonsmokers. PMID:3936704

  13. Photoacoustic spectroscopy as a tool for determination of food dyes: comparison with first derivative spectrophotometry.

    PubMed

    Coelho, T M; Vidotti, E C; Rollemberg, M C; Medina, A N; Baesso, M L; Cella, N; Bento, A C

    2010-04-15

    Photoacoustic spectroscopy (PAS) was applied as a method to quantify dyed food samples, and was compared with First Derivative Spectrophotometry (FDS). The dyes Brilliant Blue (B), Sunset Yellow (S) and Tartrazine (T), which are common food additives, were employed for the comparisons. Polyester-type Polyurethane (PU) foam was used for extraction of the dyes from a solution containing the food matrix. For the spectrophotometric determinations, the adsorbed dyes were recovered by using dimethylformamide. The PAS measurements were carried out directly on the PU foam. The PAS method showed greater sensitivity, with detection limits of 0.028 mg L(-1) and 0.086 mg L(-1) for S and T, respectively, in the S+T mixture, and of 0.012 mg L(-1) and 0.068 mg L(-1) for B and T, respectively, in the B+T mixture. The values of relative error obtained for all the dyes were small: approximately 0.3-3.6% for the spectrophotometer, and approximately 0.1-2.9% for the PAS method. The PAS technique can be applied to the determination of the selected dyes in commercial food products, with some advantages: it reduces the number of analysis steps, it is a "green" method with less chemical waste, a minimal sample amount is needed, and it is non-destructive.

  14. A New Concept for Spectrophotometry of Exoplanets with Space-borne Telescopes

    NASA Astrophysics Data System (ADS)

    Matsuo, Taro; Itoh, Satoshi; Shibai, Hiroshi; Sumi, Takahiro; Yamamuro, Tomoyasu

    2016-06-01

    We propose a new concept for the spectral characterization of transiting exoplanets with future space-based telescopes. This concept, called densified pupil spectroscopy, allows us to perform high, stable spectrophotometry against telescope pointing jitter and deformation of the primary mirror. This densified pupil spectrometer comprises the following three roles: division of a pupil into a number of sub-pupils, densification of each sub-pupil, and acquisition of the spectrum of each sub-pupil with a conventional spectrometer. Focusing on the fact that the divided and densified sub-pupil can be treated as a point source, we discovered that a simplified spectrometer allows us to acquire the spectra of the densified sub-pupils on the detector plane-an optical conjugate with the primary mirror-by putting the divided and densified sub-pupils on the entrance slit of the spectrometer. The acquired multiple spectra are not principally moved on the detector against low-order aberrations such as the telescope pointing jitter and any deformation of the primary mirror. The reliability of the observation result is also increased by statistically treating them. Our numerical calculations show that because this method suppresses the instrumental systematic errors down to 10 ppm under telescopes with modest pointing accuracy, next generation space telescopes with more than 2.5 m diameter potentially provide opportunities to characterize temperate super-Earths around nearby late-type stars through the transmission spectroscopy and secondary eclipse.

  15. Spectrophotometry of Mars during the 1992-1993 Visibility Period

    NASA Astrophysics Data System (ADS)

    Vdovichenko, V. D.; Nosova, T. P.; Kirienko, G. A.

    The results of photoelectric spectral observations of the parts of the Martian surface corresponding to the whole central meridian of the planet in the 320-1100-nm wavelength region are presented for a wide range of the planet's longitudes. The effect of the phase angle on the albedo is examined as a function of the wavelength. The presence of fine absorption features in the 350-800-nm range is established, as well as their identity over the entire range of longitudes. A `pyroxenic' absorption band is recorded reliably in all spectra in the 800-1100-nm range, whose intensity exhibits a slight longitudinal dependence. The results of observations are compared with the data of other researchers on the basis of the analysis of the literary material available.

  16. 3 micron spectrophotometry of Comet Halley - Evidence for water ice

    NASA Technical Reports Server (NTRS)

    Bregman, Jesse D.; Tielens, A. G. G. M.; Witteborn, Fred C.; Rank, David M.; Wooden, Diane

    1988-01-01

    Structure has been observed in the 3-3.6 micron preperihelion spectrum of Comet Halley consistent with either an absorption band near 3.1 microns or emission near 3.3 microns. The results suggest that a large fraction of the water molecules lost by the comet are initially ejected in the form of small ice particles rather than in the gas phase.

  17. Spectrophotometry at 10 microns of T Tauri stars

    NASA Technical Reports Server (NTRS)

    Cohen, M.; Witteborn, F. C.

    1985-01-01

    New 8-13 micron spectra of 32 T Tau, or related young, stars are presented. Silicate emission features are commonly seen. Absorptions occur less frequently but also match the properties of silicate materials. The shape of the emission feature suggests that a more crystalline grain is responsible in the T Tau stars than those of the Trapezium region. The evolution of the silicate component of the circumstellar shell around T Tau stars, and its dependence upon stellar wind activity, visual linear polarization, and extinction are investigated. Several correlations suggest that the shells are likely to be flattened, disklike structures rather than spherical.

  18. [Study on the hydrolysis distribution of ferric saline by infrared spectrophotometry and single crystal X-ray diffraction method].

    PubMed

    Zheng, Huai-Li; Xie, Li-Guo; Gao, Chao-Yong; Sun, Xiu-Ping; Yang, You; Tang, Xue

    2009-02-01

    The hydrolytic stability of Fe(a), Fe(b) and Fe(c) in different pH values of poly-ferric-flocculants was studied by using Fe-ferron time by time complexation colorimetry. The research results showed that Fe(b) was unstable, and all Fe(b) was transformed to Fe(c) after 10-15 d placement. The content of Fe(c) tended towards stability after 10-15 d. Also, the content of Fe(a) tended towards stability after 10 d. The single crystal was synthesized by the method of direct crystallization in Fe(III)-SO4(2-) water solution at normal temperature and its structure characteristic was studied by single crystal X ray diffraction method and IR (infrared spectrophotometry). The research results showed that there was no group of Fe-OH-Fe, Fe-OH and binary ferric complexed with two hydroxyl groups in the single crystal synthesized from the ferric aqueous solution in low pH (pH was about 0.5). The form of Fe in single crystal was all Fe(III). The chemical formula of the single crystal was Fe(H2O)6 (SO4)2NH4 x 6H2O when the ammonia water was used as the alkalinizing agent. One reason was that with the evaporation of water, these single crystals were synthesized at pH 0. 5 despite of different initial pH and different initial alkalinizing agents. Another reason was that the hydrolysis distribution of ferric saline was unstable. Therefore, it was not easy to obtain the single crystal of Fe(III)-hydroxy complexes or Fe(III)-polymer at low pH value. The study showed that infrared spectrophotometry and single crystal X ray diffraction method have a good prospect in the research on hydrolysis distribution of flocculants.

  19. Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry.

    PubMed

    Amin, Alaa S; El-Sharjawy, Abdel-Azeem M; Kassem, Mohammed A

    2013-06-01

    A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene-divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5-12.0 μg L(-1) of Tl(III) with relative standard deviation (RSD) of 1.40% (n=10). The detection and quantification limits are 150 and 495 ng L(-1) using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31×10(7) L mol(-1)cm(-1) and 0.00156 ng cm(-2), respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples.

  20. Near-Infrared Spectrophotometry of Phobos and Deimos

    NASA Technical Reports Server (NTRS)

    Rivkin, A. S.; Brown, R. H.; Trilling, D. E.; Bell, J. F., III; Plassmann, J. H.

    2002-01-01

    We have observed the leading and trailing hemispheres of Phobos from 1.65 to 3.5 microns and Deimos from 1.65 to 3.12 microns near opposition. We find the trailing hemisphere of Phobos to be brighter than its leading hemisphere by 0.24 +/- 0.06 magnitude at 1.65 microns and brighter than Deimos by 0.98 +/- 0.07 magnitude at 1.65 microns. We see no difference larger than observational uncertainties in spectral slope between the leading and trailing hemispheres when the spectra are normalized to 1.65 microns. We find no 3-microns absorption feature due to hydrated minerals on either hemisphere to a level of approx. 5 - 10% on Phobos and approx. 20% on Deimos. When the infrared data are joined to visible and near-IR data obtained by previous workers, our data suggest the leading (Stickney-dominated) side of Phobos is best matched by T-class asteroids. The spectral slope of the trailing side of Phobos and leading side of Deimos are bracketed by the D-class asteroids. The best laboratory spectral matches to these parts of Phobos are mature lunar soils and heated carbonaceous chondrites. The lack of 3-microns absorption features on either side of Phobos argues against the presence of a large interior reservoir of water ice according to current models of Phobos' interior.

  1. Near-Infrared Spectrophotometry of Phobos and Deimos

    NASA Technical Reports Server (NTRS)

    Rivkin, A. S.; Brown, R. H.; Trilling, D. E.; Bell, J. F., III; Plassmann, J. H.

    2002-01-01

    We have observed the leading and trailing hemispheres of Phobos from 1.65 to 3.5 micrometers and Deimos from 1.65 to 3.12 micrometers near opposition. We find the trailing hemisphere of Phobos to be brighter than its leading hemisphere by 0.24 plus or minus 0.06 magnitude at 1.65 micrometers and brighter than Deimos by 0.98 plus or minus 0.07 magnitude at 1.65 micrometers. We see no difference larger than observational uncertainties in spectral slope between the leading and trailing hemispheres when the spectra are normalized to 1.65 micrometers. We find no 3-micrometer absorption feature due to hydrated minerals on either hemisphere to a level of approximately 5-10% on Phobos and approximately 20% on Deimos. When the infrared data are joined to visible and nearby data obtained by previous workers, our data suggest the leading (Stickney-dominated) side of Phobos is best matched by T-class asteroids. The spectral slope of the trailing side of Phobos and leading side of Deimos are bracketed by the D-class asteroids. The best laboratory spectral matches to these parts of Phobos are mature lunar soils and heated carbonaceous chondrites. The lack of 3-micrometer absorption features on either side of Phobos argues against the presence of a large interior reservoir of water ice according to current models of Phobos' interior.

  2. Near-Infrared Spectrophotometry of Phobos and Deimos

    NASA Technical Reports Server (NTRS)

    Rivkin, A. S.; Brown, R. H.; Trilling, D. E.; Bell, J. F., III; Plassmann, J. H.

    2002-01-01

    We have observed the leading and trailing hemispheres of Phobos from 1.65 to 3.5 microns and Deimos from 1.65 to 3.12 microns near opposition. We find the trailing hemisphere of Phobos to be brighter than its leading hemisphere by 0.24 +/- 0.06 magnitude at 1.65 microns and brighter than Deimos by 0.98 +/- 0.07 magnitude at 1.65 microns. We see no difference larger than observational uncertainties in spectral slope between the leading and trailing hemispheres when the spectra are normalized to 1.65 microns. We find no 3-micron absorption feature due to hydrated minerals on either hemisphere to a level of approx. 5-10% on Phobos and approx. 20% on Deimos. When the infrared data are joined to visible and near-IR data obtained by previous workers, our data suggest the leading (Stickney-dominated) side of Phobos is best matched by T-class asteroids. The spectral slope of the trailing side of Phobos and leading side of Deimos are bracketed by the D-class asteroids. The best laboratory spectral matches to these parts of Phobos are mature lunar soils and heated carbonaceous chondrites. The lack of 3-micron absorption features on either side of Phobos argues against the presence of a large interior reservoir of water ice according to current models of Phobos' interior.

  3. Spectrophotometry of peculiar B and A stars. XVIII - The helium rich variable stars HR 1890, Sigma Orionis E, and HD 37776

    NASA Technical Reports Server (NTRS)

    Adelman, S. J.; Pyper, D. M.

    1985-01-01

    Optical region spectrophotometry at 3300-7850 A has been obtained for three helium rich stars, HR 1890, Sigma Ori E, and HD 37776, of the Orion OB1 Association. New uvby-beta photometry of HR 1890 and HD 37776 as well as published data are also used to investigate the variability of these stars. A new period of 1.53862 days was determined for HD 37776. For all three stars H-beta varies in antiphase with strong He I lines. The spectrophotometric bandpass containing the strong He I line at 4471 A varies in phase with the R index of Pedersen and Thomsen (1977). Evidence is found for weak absorption features which appear to be an extension of the 5200 A feature seen in cooler CP stars.

  4. [Determination of physiological indices in Albizzia julibrissin Durazz seedlings under alkaline stress with visible spectrophotometry].

    PubMed

    Zhou, Jian; Zhang, Lin; Yuan, De-Yi; Qi, An-Guo

    2008-02-01

    There is a large area of saline-alkali soil in our country, and soil alkalization is always a problem affecting urban gardening. To examine the capacity of alkaline resistance of Albizzia julibrissin Durazz seedlings, the contents of MDA, soluble sugar and proline, and the activity of POD and SOD in Albizzia julibrissin durazz tree body were measured by means of visible spectrophotometry. Also, the change patterns of the five indexes with different treatment concentration and time were analyzed. Attempts were then made to elucidate the physiological mechanism of how alkaline stress affects the growth of the Albizzia julibrissin durazz tree, which could provide theoretical foundation for planting and gardening and an approach to dealing with the difficulties in planting and gardening in saline and alkaline area. The results showed that with the increase in Na2 CO3 concentration, the contents of MDA and soluble sugar in the leaves slowly ascended when the treatment concentration was lower than 75 mmol x L(-1), and then rapidly increased when the treatment concentration was higher than 75 mmol x L(-1); There were significant differences between different treatments. Proline content exhibited the same change pattern with MDA and soluble sugar. It slowly ascended when the treatment concentration was lower than 100 mmol x L(-1), whereas it sharply increased when the treatment concentration was above 100 mmol x L(-1); The changes in SOD and POD were similar, showing a unimodal pattern. However, the treatment concentration corresponding to the maximum of SOD and POD was 50 and 75 mmol x L(-1), respectively. With the changes in stress time, in addition, the contents of MDA treated with the same concentration increased gradually. However, praline, soluble sugar, SOD and POD changed irregularly. These results indicated that Albizzia julibrissin Durazz could resist the alkaline stress by modulating values of physical indexes such as the contents of MDA, soluble sugar and

  5. Methane absorption variations in the spectrum of Pluto

    SciTech Connect

    Buie, M.W.; Fink, U.

    1987-06-01

    The lightcurve phases of 0.18, 0.35, 0.49, and 0.98 covered by 5600-10,500 A absolute spectrophotometry of Pluto during four nights include minimum (0.98) light and one near-maximum (0.49) light. The spectra are noted to exhibit significant methane band absorption depth variations at 6200, 7200, 7900, 8400, 8600, 8900, and 10,000 A, with the minimum absorption occurring at minimum light and thereby indicating a 30-percent change in the methane column abundance in the course of three days. An attempt is made to model this absorption strength variation with rotational phase terms of an isotropic surface distribution of methane frost and a clear layer of CH4 gas. 34 references.

  6. Light absorption properties and absorption budget of Southeast Pacific waters

    NASA Astrophysics Data System (ADS)

    Bricaud, Annick; Babin, Marcel; Claustre, Hervé; Ras, JoséPhine; TièChe, Fanny

    2010-08-01

    Absorption coefficients of phytoplankton, nonalgal particles (NAPs), and colored dissolved organic matter (CDOM), and their relative contributions to total light absorption, are essential variables for bio-optical and biogeochemical models. However, their actual variations in the open ocean remain poorly documented, particularly for clear waters because of the difficulty in measuring very low absorption coefficients. The Biogeochemistry and Optics South Pacific Experiment (BIOSOPE) cruise investigated a large range of oceanic regimes, from mesotrophic waters around the Marquesas Islands to hyperoligotrophic waters in the subtropical gyre and eutrophic waters in the upwelling area off Chile. The spectral absorption coefficients of phytoplankton and NAPs were determined using the filter technique, while the CDOM absorption coefficients were measured using a 2 m capillary waveguide. Over the whole transect, the absorption coefficients of both dissolved and particulate components covered approximately two orders of magnitude; in the gyre, they were among the lowest ever reported for open ocean waters. In the oligotrophic and mesotrophic waters, absorption coefficients of phytoplankton and NAPs were notably lower than those measured in other oceanic areas with similar chlorophyll contents, indicating some deviation from the standard chlorophyll-absorption relationships. The contribution of absorption by NAPs to total particulate absorption showed large vertical and horizontal variations. CDOM absorption coefficients covaried with algal biomass, albeit with a high scatter. The spectral slopes of both NAP and CDOM absorption revealed structured spatial variability in relation with the trophic conditions. The relative contributions of each component to total nonwater absorption were (at a given wavelength) weakly variable over the transect, at least within the euphotic layer.

  7. Identification of Organic Colorants in Art Objects by Solution Spectrophotometry: Pigments.

    ERIC Educational Resources Information Center

    Billmeyer, Fred W., Jr.; And Others

    1981-01-01

    Describes solution spectrophotometry as a simple, rapid identification technique for organic paint pigments. Reports research which includes analytical schemes for the extraction and separation of organic pigments based on their solubilities, and the preparation of an extensive reference collection of spectral curves allowing their identification.…

  8. High resolution spectrophotometry for identification of chlorine dioxide in concentrated chlorine solutions.

    PubMed

    Gauw, R D; Emmert, G L; Bubnis, B; Gordon, G

    1999-12-01

    Electrolyzed salt brine generators hold great promise for water disinfection in small communities and remote locations. Electrolysis cell liquors have been reported to contain chlorine, chlorine dioxide and ozone. High resolution spectrophotometry was used to observe the presence (or absence) of a unique spectral absorbance pattern present in solutions containing 1-2 mg/l chlorine dioxide. PMID:18967802

  9. Atomic absorption spectrophotometric and X-ray studies of respirable dusts in Indian coal mines

    SciTech Connect

    Rawat, N.S.; Sinha, J.D.; Sahoo, B.

    1982-01-01

    Quantitative determination of 10 minor and 8 trace elements in respirable coal dust by atomic absorption spectrophotometry is described herein. The coal dust samples were collected in the mine atmosphere during drilling in coal seams. A ''Hexhlet'' appratus specially designed and fitted with a horizontal elutriator was used to collect the respirable coal dust fraction. After destruction of organic matter by wet oxidation and filtering off the clay and silica, iron, calcium, magnesium, sodium, potassium, manganese, zinc, copper, cadmium, and nickel were determined directly in the resulting solution by atomic absorption spectrophotometry. The studies relate to a respiratoy disease-pneumoconiosis-affecting coal mine workers. X-Ray diffraction studies have shown the presence of kaolin, quartz, pirrsonite and beidellite clay minerals in the coal dust.

  10. Transient absorption spectroscopy of laser shocked explosives

    SciTech Connect

    Mcgrane, Shawn D; Dang, Nhan C; Whitley, Von H; Bolome, Cindy A; Moore, D S

    2010-01-01

    Transient absorption spectra from 390-890 nm of laser shocked RDX, PETN, sapphire, and polyvinylnitrate (PVN) at sub-nanosecond time scales are reported. RDX shows a nearly linear increase in absorption with time after shock at {approx}23 GPa. PETN is similar, but with smaller total absorption. A broad visible absorption in sapphire begins nearly immediately upon shock loading but does not build over time. PVN exhibits thin film interference in the absorption spectra along with increased absorption with time. The absorptions in RDX and PETN are suggested to originate in chemical reactions happening on picosecond time scales at these shock stresses, although further diagnostics are required to prove this interpretation.

  11. ABSORPTION ANALYZER

    DOEpatents

    Brooksbank, W.A. Jr.; Leddicotte, G.W.; Strain, J.E.; Hendon, H.H. Jr.

    1961-11-14

    A means was developed for continuously computing and indicating the isotopic assay of a process solution and for automatically controlling the process output of isotope separation equipment to provide a continuous output of the desired isotopic ratio. A counter tube is surrounded with a sample to be analyzed so that the tube is exactly in the center of the sample. A source of fast neutrons is provided and is spaced from the sample. The neutrons from the source are thermalized by causing them to pass through a neutron moderator, and the neutrons are allowed to diffuse radially through the sample to actuate the counter. A reference counter in a known sample of pure solvent is also actuated by the thermal neutrons from the neutron source. The number of neutrons which actuate the detectors is a function of a concentration of the elements in solution and their neutron absorption cross sections. The pulses produced by the detectors responsive to each neu tron passing therethrough are amplified and counted. The respective times required to accumulate a selected number of counts are measured by associated timing devices. The concentration of a particular element in solution may be determined by utilizing the following relation: T2/Ti = BCR, where B is a constant proportional to the absorption cross sections, T2 is the time of count collection for the unknown solution, Ti is the time of count collection for the pure solvent, R is the isotopic ratlo, and C is the molar concentration of the element to be determined. Knowing the slope constant B for any element and when the chemical concentration is known, the isotopic concentration may be readily determined, and conversely when the isotopic ratio is known, the chemical concentrations may be determined. (AEC)

  12. Vacuum ultraviolet spectrophotometry and effective temperatures of hot stars

    NASA Technical Reports Server (NTRS)

    Brune, W. H.; Mount, G. H.; Feldman, P. D.

    1979-01-01

    Absolutely calibrated ultraviolet stellar spectra from 3100 A to the hydrogen absorption edge at 912 A were obtained on 1977 February 17 by rocket observations above Woomera, Australia. Spectra taken at 15 A resolution have been compared with the observed fluxes from OAO 2 and with recent model-atmosphere fluxes of Kurucz for five hot stars: Gamma (2) Vel, Zeta Pup, Alpha Eri, Beta Cen, and Alpha Vir. The present data give fluxes which are generally lower than those obtained from OAO 2, with the largest deviations of about 20% between 1400 and 1700 A. Agreement with the models is good, although the model fluxes are substantially larger than the observed values below 1200 A. This discrepancy is greater for the higher-temperature stars. Effective temperatures are also determined and are in good agreement with previous results.

  13. Spectrophotometry of emission-line stars in the magellanic clouds

    NASA Technical Reports Server (NTRS)

    Bohannan, Bruce

    1990-01-01

    The strong emission lines in the most luminous stars in the Magellanic Clouds indicate that these stars have such strong stellar winds that their photospheres are so masked that optical absorption lines do not provide an accurate measure of photospheric conditions. In the research funded by this grant, temperatures and gravities of emission-line stars both in the Large (LMC) and Small Magellanic Clouds (SMC) have been measured by fitting of continuum ultraviolet-optical fluxes observed with IUE with theoretical model atmospheres. Preliminary results from this work formed a major part of an invited review 'The Distribution of Types of Luminous Blue Variables'. Interpretation of the IUE observations obtained in this grant and archive data were also included in a talk at the First Boulder-Munich Hot Stars Workshop. Final results of these studies are now being completed for publication in refereed journals.

  14. UV spectrophotometry for monitoring the performance of a yeast-based deoxygenation process to treat ships' ballast water.

    PubMed

    Veilleux, Éloïse; de Lafontaine, Yves; Thomas, Olivier

    2016-04-01

    This study assessed the usefulness of UV spectrophotometry for the monitoring of a yeast-based deoxygenation process proposed for ships' ballast water treatment to prevent the transfer of aquatic invasive species. Ten-day laboratory experiments using three treatment concentrations and different water types were conducted and resulted in complete oxygen depletion of treated waters. The treatment performance and quality of treated waters were determined by measuring the UV-visible absorbance spectra of water samples taken over time. Samples were also used for laboratory analysis of water quality properties. The UV absorbance spectra values were strongly correlated (r = 0.96) to yeast cell density in treated waters. The second-order derivative (D (2)) of the spectra varied greatly over time, and the spectrum profiles could be divided into two groups corresponding to the oxygenated and anoxic phases of the treatment. The D (2) value at 215 nm was strongly correlated (r = 0.94) to ammonia levels, which increased over time. The D (2) value at 225 nm was strongly correlated (r > 0.97) to DO concentration. Our results showed that UV spectrophotometry may provide a rapid assessment of the behavior and performance of the yeast bioreactor over time by quantifying (1) the density of yeast cells, (2) the time at which anoxic conditions were reached, and (3) a water quality index of the treated water related to the production of ammonia. We conclude that the rapidity of the technique confers a solid advantage over standard methods used for water quality analysis in laboratory and would permit the direct monitoring of the treatment performance on-board ships. PMID:26944435

  15. UV spectrophotometry for monitoring the performance of a yeast-based deoxygenation process to treat ships' ballast water.

    PubMed

    Veilleux, Éloïse; de Lafontaine, Yves; Thomas, Olivier

    2016-04-01

    This study assessed the usefulness of UV spectrophotometry for the monitoring of a yeast-based deoxygenation process proposed for ships' ballast water treatment to prevent the transfer of aquatic invasive species. Ten-day laboratory experiments using three treatment concentrations and different water types were conducted and resulted in complete oxygen depletion of treated waters. The treatment performance and quality of treated waters were determined by measuring the UV-visible absorbance spectra of water samples taken over time. Samples were also used for laboratory analysis of water quality properties. The UV absorbance spectra values were strongly correlated (r = 0.96) to yeast cell density in treated waters. The second-order derivative (D (2)) of the spectra varied greatly over time, and the spectrum profiles could be divided into two groups corresponding to the oxygenated and anoxic phases of the treatment. The D (2) value at 215 nm was strongly correlated (r = 0.94) to ammonia levels, which increased over time. The D (2) value at 225 nm was strongly correlated (r > 0.97) to DO concentration. Our results showed that UV spectrophotometry may provide a rapid assessment of the behavior and performance of the yeast bioreactor over time by quantifying (1) the density of yeast cells, (2) the time at which anoxic conditions were reached, and (3) a water quality index of the treated water related to the production of ammonia. We conclude that the rapidity of the technique confers a solid advantage over standard methods used for water quality analysis in laboratory and would permit the direct monitoring of the treatment performance on-board ships.

  16. Selective determination of the holmium in rare earth mixtures by second derivative spectrophotometry with 2-isobutylformyl-1,3-dione-indan and octylphenol poly-(ethyleneglycol)ether

    SciTech Connect

    Wang Naixing; Si Zhikun; Jiang Wei

    1996-09-01

    In this paper the absorption spectra of 4f electron transitions of the system of holmium with 2-isobutylformyl-1,3-dione-indan and TX-100 have been studied by normal and derivative spectrophotometry. The molar absorptivities are 98 (at 450 nm) and 21 (at 460 nm) 1 {center_dot} mol{sup -1} {center_dot} cm{sup -1}, respectively. The use of the second derivative spectra, eliminates the interference by other lanthanides and improves the sensitivity for holmium determination. The derivative molar absorptivity is 558 1 {center_dot} mol{sup -1} {center_dot} cm{sup -1}. The calibration graph was linear up to 25{mu}g/ml of holmium. The relative standard deviation evaluated from ten independent determinations of 8.0 {mu}g/ml holmium is 1.0%. The detection limit, obtained from the sensitivity of the calibration graph and for 3 S{sub b} (S{sub b} = standard deviation of a blank without holmium, n = 11), was found to be 0.31 {mu}g/ml of holmium. The quantification limit, obtained for 10 S{sub b}, was 1.0 {mu}g/ml of holmium. A method has been developed for determining holmium in a mixture of lanthanides by means of the second derivative spectra and the analytical results obtained are satisfactory.

  17. Cracking the perfusion code?: Laser-assisted Indocyanine Green angiography and combined laser Doppler spectrophotometry for intraoperative evaluation of tissue perfusion in autologous breast reconstruction with DIEP or ms-TRAM flaps.

    PubMed

    Ludolph, Ingo; Arkudas, Andreas; Schmitz, Marweh; Boos, Anja M; Taeger, Christian D; Rother, Ulrich; Horch, Raymund E; Beier, Justus P

    2016-10-01

    The aim of this prospective study was to assess the correlation of flap perfusion analysis based on laser-assisted Indocyanine Green (ICG) angiography with combined laser Doppler spectrophotometry in autologous breast reconstruction using free DIEP/ms-TRAM flaps. Between February 2014 and July 2015, 35 free DIEP/ms-TRAM flaps were included in this study. Besides the clinical evaluation of flaps, intraoperative perfusion dynamics were assessed by means of laser-assisted ICG angiography and post-capillary oxygen saturation and relative haemoglobin content (rHb) using combined laser Doppler spectrophotometry. Correlation of the aforementioned parameters was analysed, as well as the impact on flap design and postoperative complications. Flap survival rate was 100%. There were no partial flap losses. In three cases, flap design was based on the angiography, contrary to clinical evaluation and spectrophotometry. The final decision on the inclusion of flap areas was based on the angiographic perfusion pattern. Angiography and spectrophotometry showed a correlation in most of the cases regarding tissue perfusion, post-capillary oxygen saturation and relative haemoglobin content. Laser-assisted ICG angiography is a useful tool for intraoperative evaluation of flap perfusion in autologous breast reconstruction with DIEP/ms-TRAM flaps, especially in decision making in cases where flap perfusion is not clearly assessable by clinical signs and exact determination of well-perfused flap margins is difficult to obtain. It provides an objective real-time analysis of flap perfusion, with high sensitivity for the detection of poorly perfused flap areas. Concerning the topographical mapping of well-perfused flap areas, laser-assisted angiography is superior to combined laser Doppler spectrophotometry.

  18. Spectrophotometry, colors, and photometric properties of the 67P/Churyumov-Gerasimenko nucleus from the OSIRIS instrument onboard the ROSETTA mission

    NASA Astrophysics Data System (ADS)

    Fornasier, Sonia; Hasselmann, Pedro; Feller, Clement; Barucci, Maria Antonietta; Lara, Luisa; Oklay, Nilda; Tubiana, Cecilia; Besse, Sebastien; Scholten, Frank; Sierks, Holger; Leyrat, Cedric; La Forgia, Fiorangela; Lazzarin, Monica; Pajola, Maurizio; Thomas, Nick; Pommerol, Antoine; Massironi, Matteo

    2015-04-01

    Rosetta is the cornerstone mission of the European Space Agency devoted to the study of Solar System minor bodies. Launched on 2 March 2004, Rosetta arrived on August 6, 2014, at the comet 67P/Churyumov-Gerasimenko after 10 years of interplanetary journey. Rosetta is now in the main science escort phase of the comet after the successful delivery of the lander Philae on its surface on November 12, 2014. In this work we present the results on the 67P nucleus physical properties derived from the OSIRIS imaging system observations obtained in July- mid August 2014, during the comet approach phase and the first bound orbits. In this timeframe, OSIRIS has mapped the comet surface with a resolution up to 2 m/px with several filters covering the 250-1000 nm range, and at different phase angles (1.3-54 degrees). The images have been reduced using the OSIRIS standard pipeline, and then transformed into I/F reflectance. A 3D shape model of the nucleus, determined from the images obtained during the mapping phase, has been used to retrieve the illumination and geometric conditions of each image. Color cubes of the surface have been hence produced by stacking registered and photometrically corrected images. Globally, the nucleus has spectrophotometric properties in the NUV-VIS-NIR range similar to those of bare cometary nuclei, of primitive D-type asteroids such us Jupiter Trojans, and of the moderately red Transneptunians and Centaurs. No clear absorption bands have been detected so far at the resolution of the used filters. The global spectral slope, evaluated in the 535-880 nm range, varies between 11 %/(100 nm) at a phase angle of 1.3 degrees and 16 %/(100 nm) at a phase angle of 52 degrees, implying a significant phase reddening. Despite the different types of terrains and morphological features seen on the comet (Thomas et al. 2015), the nucleus shows small color variations, with the notable exception of the Hapi region (Sierks et al., 2015). This region is located

  19. Design of Terahertz-Wave Spectrophotometry by Compton Backscattering Using Relativistic Electron Bunches and their Coherent Synchrotron Radiations

    NASA Astrophysics Data System (ADS)

    Sei, Norihiro; Kuroda, Ryunosuke; Ogawa, Hiroshi

    2008-08-01

    We propose a new terahertz-wave spectrophotometry by Compton backscattering using relativistic electron bunches and coherent radiations generated by them. The terahertz-wave spectrophotometry can be realized simultaneously with Compton backscattering, where the characteristics in the terahertz-wave region are converted to those in the visible and ultraviolet regions. The number of Compton backscattered photons is estimated to be more than 100 counts per second with a wavelength divergence of 5% in the visible and ultraviolet regions using the compact S-band linac at National Institute of Advanced Industrial Science and Technology. This spectrophotometry becomes significant in energy recovery linacs.

  20. Solubility of Lead Sulfate in Water and in Sodium Sulfate Solutions: An Experiment in Atomic Absorption Spectrophotometry.

    ERIC Educational Resources Information Center

    Lehman, Thomas A.; Everett, Wayne W.

    1982-01-01

    Describes a set of undergraduate laboratory experiments which provide experience in deuteration and derivatization procedures applied to infrared spectroscopy. Basic skills in vacuum-line technique are also taught while measuring infrared spectra of deuterated solid samples and demonstrating the value of derivatization as an aid to interpreting…

  1. Coordinated Time Resolved Spectrophotometry of Asteroid 163249 (2002 GT)

    NASA Astrophysics Data System (ADS)

    Ryan, Erin L.; Woodward, C.; Gordon, M.; Wagner, M. R.; Chesley, S.; Hicks, M.; Pittichova, J.; Pravec, P.

    2013-10-01

    The near-Earth asteroid 163249 (2002 GT), classified as a potentially hazardous asteroid (PHA), has been identified a potential rendezvous target for the NASA Deep Impact spacecraft on 4 Jan 2020. As part of a coordinated international effort to study this asteroid during its 2013 apparition (J. Pittichová et al. DPS 2013), we obtained simultaneous Sloan r-band photometry at the Steward Observatory Bok 2.3-m telescope (+90Prime) and optical spectroscopic observations covering a wavelength interval from ~5400 to ~8500 Angstrom at the MMT 6.5-m (+RedChannel spectrograph) on 2013 June 16 and 17 UT near close Earth approach (heliocentric distance ~1.07 AU; geocentric distance ~0.13 AU) at 180 sec intervals over the ~3.76 hr rotational period. Our objective was to obtain a temporal sequence of spectra to assess surface mineralogy (seeking to potentially detect the 0.7 micron absorption bands attributed to phylosilicate materials) and to determine whether variations in the spectral slope and/or surface mineralogy are evident as a function of rotational period. Here we present initial analysis of these datasets, describing the light-curve and the reflectance spectra as a function of rotational phase. These datasets will be incorporated into a larger compendium describing the characteristics of asteroid 163249. Acknowledgement: This research supported in part by NASA 12-PAST-12-0010 grant NNX13AJ11G , and an appointment (E.L.R.) to the NASA Postdoctoral Program at the Goddard Space Flight Center, administered by Oak Ridge Associated Universities through a contract with NASA. Observations reported here were obtained at the MMT Observatory, a joint facility of the Smithsonian Institution and the University of Arizona. P.P. was supported by the Grant Agency of the Czech Republic, Grant P209/12/0229.

  2. Absorption driven focus shift

    NASA Astrophysics Data System (ADS)

    Harrop, N.; Wolf, S.; Maerten, O.; Dudek, K.; Ballach, S.; Kramer, R.

    2016-03-01

    Modern high brilliance near infrared lasers have seen a tremendous growth in applications throughout the world. Increased productivity has been achieved by higher laser power and increased brilliance of lasers. Positive impacts on the performance and costs of parts are opposed to threats on process stability and quality, namely shift of focus position over time. A high initial process quality will be reduced by contamination of optics, eventually leading to a focus shift or even destruction of the optics. Focus analysis at full power of multi-kilowatt high brilliance lasers is a very demanding task because of high power densities in the spot and the high power load on optical elements. With the newly developed high power projection optics, the High-Power Micro-Spot Monitor High Brilliance (HP-MSM-HB) is able to measure focus diameter as low as 20 μm at power levels up to 10 kW at very low internal focus shift. A main driving factor behind thermally induced focus shift is the absorption level of the optical element. A newly developed measuring system is designed to determine the relative absorption level in reference to a gold standard. Test results presented show a direct correlation between absorption levels and focus shift. The ability to determine the absorption level of optical elements as well as their performance at full processing power before they are put to use, enables a high level of quality assurance for optics manufacturers and processing head manufacturers alike.

  3. [Noninvasive total hemoglobin monitoring based on multiwave spectrophotometry in obstetrics and gynecology].

    PubMed

    Pyregov, A V; Ovechkin, A Iu; Petrov, S V

    2012-01-01

    Results of prospective randomized comparative research of 2 total hemoglobin estimation methods are presented. There were laboratory tests and continuous noninvasive technique with multiwave spectrophotometry on the Masimo Rainbow SET. Research was carried out in two stages. At the 1st stage (gynecology)--67 patients were included and in second stage (obstetrics)--44 patients during and after Cesarean section. The standard deviation of noninvasive total hemoglobin estimation from absolute values (invasive) was 7.2 and 4.1%, an standard deviation in a sample--5.2 and 2.7 % in gynecologic operations and surgical delivery respectively, that confirms lack of reliable indicators differences. The method of continuous noninvasive total hemoglobin estimation with multiwave spectrophotometry on the Masimo Rainbow SET technology can be recommended for use in obstetrics and gynecology.

  4. Monitoring of monosaccharides, oligosaccharides, ethanol and glycerol during wort fermentation by biosensors, HPLC and spectrophotometry.

    PubMed

    Monošík, Rastislav; Magdolen, Peter; Stredanský, Miroslav; Šturdík, Ernest

    2013-05-01

    The aim of the present study was to analyze sugar levels (namely maltose, maltotriose, glucose and fructose) and alcohols (ethanol and glycerol) during the fermentation process in wort samples by amperometric enzymatic biosensors developed by our research group for industrial application, HPLC and spectrophotometry, and to compare the suitability of the presented methods for determination of individual analytes. We can conclude that for the specific monitoring of maltose or maltotriose only the HPLC method was suitable. On the other hand, biosensors and spectrophotometry reflected a decrease in total sugar concentration better and were able to detect both glucose and fructose in the later stages of fermentation, while HPLC was not. This can be attributed to the low detection limits and good sensitivity of the proposed methods. For the ethanol and glycerol analysis all methods proved to be suitable. However, concerning the cost expenses and time analysis, biosensors represented the best option.

  5. Spectrophotometry of faint light sources with a tilting-filter photometer.

    PubMed

    Eather, R H; Reasoner, D L

    1969-02-01

    The design considerations that are necessary to optimize the performance of a tilting-filter photometer are presented. Such a photometer is described, and some typical measurements of aurora and airglow illustrate the application of this technique to low light level spectrophotometry. The digital approach used with photomultipliers at these low light levels is also discussed. Comparison of the tilting-filter photometer with other spectral scanning instruments reveals a superiority for many applications. A final section discusses possible space applications.

  6. The Use of Self-scanned Silicon Photodiode Arrays for Astronomical Spectrophotometry

    NASA Technical Reports Server (NTRS)

    Cochran, A. L.

    1984-01-01

    The use of a Reticon self scanned silicon photodiode array for precision spectrophotometry is discussed. It is shown that internal errors are + or - 0.003 mag. Observations obtained with a photodiode array are compared with observations obtained with other types of detectors with agreement, from 3500 A to 10500 A, of 1%. The photometric properties of self scanned photodiode arrays are discussed. Potential pitfalls are given.

  7. Interaction of the carbon monoxide-releasing molecule Ru(CO)3Cl(glycinate) (CORM-3) with Salmonella enterica serovar Typhimurium: in situ measurements of carbon monoxide binding by integrating cavity dual-beam spectrophotometry.

    PubMed

    Rana, Namrata; McLean, Samantha; Mann, Brian E; Poole, Robert K

    2014-12-01

    Carbon monoxide (CO) is a toxic gas that binds to haems, but also plays critical signalling and cytoprotective roles in mammalian systems; despite problems associated with systemic delivery by inhalation of the gas, it may be employed therapeutically. CO delivered to cells and tissues by CO-releasing molecules (CO-RMs) has beneficial and toxic effects not mimicked by CO gas; CO-RMs are also attractive candidates as novel antimicrobial agents. Salmonella enterica serovar Typhimurium is an enteropathogen causing gastroenteritis in humans. Recent studies have implicated haem oxygenase-1 (HO-1), the protein that catalyses the degradation of haem into biliverdin, free iron and CO, in the host immune response to Salmonella infection. In several studies, CO administration via CO-RMs elicited many of the protective roles of HO-1 induction and so we investigated the effects of a well-characterized water-soluble CO-RM, Ru(CO)3Cl(glycinate) (CORM-3), on Salmonella. CORM-3 exhibits toxic effects at concentrations significantly lower than those reported to cause toxicity to RAW 264.7 macrophages. We demonstrated here, through oxyhaemoglobin assays, that CORM-3 did not release CO spontaneously in phosphate buffer, buffered minimal medium or very rich medium. CORM-3 was, however, accumulated to high levels intracellularly (as shown by inductively coupled plasma MS) and released CO inside cells. Using growing Salmonella cultures without prior concentration, we showed for the first time that sensitive dual-beam integrating cavity absorption spectrophotometry can detect directly the CO released from CORM-3 binding in real-time to haems of the bacterial electron transport chain. The toxic effects of CO-RMs suggested potential applications as adjuvants to antibiotics in antimicrobial therapy. PMID:25085864

  8. Interaction of the carbon monoxide-releasing molecule Ru(CO)3Cl(glycinate) (CORM-3) with Salmonella enterica serovar Typhimurium: in situ measurements of carbon monoxide binding by integrating cavity dual-beam spectrophotometry.

    PubMed

    Rana, Namrata; McLean, Samantha; Mann, Brian E; Poole, Robert K

    2014-12-01

    Carbon monoxide (CO) is a toxic gas that binds to haems, but also plays critical signalling and cytoprotective roles in mammalian systems; despite problems associated with systemic delivery by inhalation of the gas, it may be employed therapeutically. CO delivered to cells and tissues by CO-releasing molecules (CO-RMs) has beneficial and toxic effects not mimicked by CO gas; CO-RMs are also attractive candidates as novel antimicrobial agents. Salmonella enterica serovar Typhimurium is an enteropathogen causing gastroenteritis in humans. Recent studies have implicated haem oxygenase-1 (HO-1), the protein that catalyses the degradation of haem into biliverdin, free iron and CO, in the host immune response to Salmonella infection. In several studies, CO administration via CO-RMs elicited many of the protective roles of HO-1 induction and so we investigated the effects of a well-characterized water-soluble CO-RM, Ru(CO)3Cl(glycinate) (CORM-3), on Salmonella. CORM-3 exhibits toxic effects at concentrations significantly lower than those reported to cause toxicity to RAW 264.7 macrophages. We demonstrated here, through oxyhaemoglobin assays, that CORM-3 did not release CO spontaneously in phosphate buffer, buffered minimal medium or very rich medium. CORM-3 was, however, accumulated to high levels intracellularly (as shown by inductively coupled plasma MS) and released CO inside cells. Using growing Salmonella cultures without prior concentration, we showed for the first time that sensitive dual-beam integrating cavity absorption spectrophotometry can detect directly the CO released from CORM-3 binding in real-time to haems of the bacterial electron transport chain. The toxic effects of CO-RMs suggested potential applications as adjuvants to antibiotics in antimicrobial therapy.

  9. Detecting estrogenic activity in water samples withestrogen-sensitive yeast cells using spectrophotometry and fluorescencemicroscopy

    SciTech Connect

    Wozei, E.; Holman, H-Y.N.; Hermanowicz, S.W.; Borglin S.

    2006-03-15

    Environmental estrogens are environmental contaminants that can mimic the biological activities of the female hormone estrogen in the endocrine system, i.e. they act as endocrine disrupters. Several substances are reported to have estrogen-like activity or estrogenic activity. These include steroid hormones, synthetic estrogens (xenoestrogens), environmental pollutants and phytoestrogens (plant estrogens). Using the chromogenic substrate ortho-nitrophenyl-{beta}-D-galactopyranoside (ONPG) we show that an estrogen-sensitive yeast strain RMY/ER-ERE, with human estrogen receptor (hER{alpha}) gene and the lacZ gene which encodes the enzyme {beta}-galactosidase, is able to detect estrogenic activity in water samples over a wide range of spiked concentrations of the hormonal estrogen 17{beta}-estradiol (E2). Ortho-nitrophenol (ONP), the yellow product of this assay can be detected using spectrophotometry but requires cell lysis to release the enzyme and allow product formation. We improved this aspect in a fluorogenic assay by using fluorescein di-{beta}-D-galactopyranoside (FDG) as a substrate. The product was visualized using fluorescence microscopy without the need to kill, fix or lyse the cells. We show that in live yeast cells, the uptake of E2 and the subsequent production of {beta}-galactosidase enzyme occur quite rapidly, with maximum enzyme-catalyzed fluorescent product formation evident after about 30 minutes of exposure to E2. The fluorogenic assay was applied to a selection of estrogenic compounds and the Synchrotron-based Fourier transform infrared (SR-FTIR) spectra of the cells obtained to better understand the yeast whole cell response to the compounds. The fluorogenic assay is most sensitive to E2, but the SR-FTIR spectra suggest that the cells respond to all the estrogenic compounds tested even when no fluorescent response was detected. These findings are promising and may shorten the duration of environmental water screening and monitoring regimes using

  10. Subgap Absorption in Conjugated Polymers

    DOE R&D Accomplishments Database

    Sinclair, M.; Seager, C. H.; McBranch, D.; Heeger, A. J; Baker, G. L.

    1991-01-01

    Along with X{sup (3)}, the magnitude of the optical absorption in the transparent window below the principal absorption edge is an important parameter which will ultimately determine the utility of conjugated polymers in active integrated optical devices. With an absorptance sensitivity of < 10{sup {minus}5}, Photothermal Deflection Spectroscopy (PDS) is ideal for determining the absorption coefficients of thin films of transparent'' materials. We have used PDS to measure the optical absorption spectra of the conjugated polymers poly(1,4-phenylene-vinylene) (and derivitives) and polydiacetylene-4BCMU in the spectral region from 0.55 eV to 3 eV. Our spectra show that the shape of the absorption edge varies considerably from polymer to polymer, with polydiacetylene-4BCMU having the steepest absorption edge. The minimum absorption coefficients measured varied somewhat with sample age and quality, but were typically in the range 1 cm{sup {minus}1} to 10 cm{sup {minus}1}. In the region below 1 eV, overtones of C-H stretching modes were observed, indicating that further improvements in transparency in this spectral region might be achieved via deuteration of fluorination.

  11. A simple vapour phase decomposition (VPD) of quartz powder in a polypropylene vessel and determination of phosphorus by spectrophotometry.

    PubMed

    Thangavel, S; Dash, K; Chaurasia, S C

    2001-09-13

    A simple, low pressure, low temperature vapour phase decomposition (VPD) of quartz powder has been developed for the determination of phosphorus. A platinum dish containing the quartz or silicon powder was placed inside a polypropylene vessel containing 40 ml of 1:1 mixture of HF and HNO(3). After capping the vessel, the entire assembly was heated on a water bath at approximately 90 degrees C for 8 h. The platinum dish was removed from the vessel, the sample solution was treated with 0.5 ml of H(2)SO(4) and 0.5 ml of HClO(4) and was heated on a hot plate till HClO(4) fumed out. The resultant solution was diluted to 40 ml ( approximately 0.4N), analysed for phosphorus by spectrophotometry as an ion-pair of molybdophosphate with crystal violet. Phosphorus contamination by reagents has been drastically reduced (around 250 times) compared to the conventional dissolution procedure. The optimum reaction conditions were [H(+)]=0.42N, [H(+)]/Mo=62 for the formation of molybdophosphate and its extraction into n-butyl acetate. No interferences due to fluoride, silicate (active silica) and arsenic (V) upto 6.7x10(3),2.7x10(3) and 2.0x10(3) times the content of phosphorus, respectively were observed. The LOD was found to be 0.066 mug g(-1) (+/-3 s). RSD is 0.4-2.3% and the molar absorptivity is 2.7x10(5) l mole(-1) cm(-1). PMID:18968395

  12. Simultaneous spectrophotometric determination of Celecoxib and Diacerein in bulk and capsule by absorption correction method and chemometric methods

    NASA Astrophysics Data System (ADS)

    Patel, N. S.; Nandurbarkar, V. P.; Patel, A. J.; Patel, S. G.

    Two methods, absorption correction and multivariate spectrophotometric methods were developed for simultaneous estimation of Celecoxib (CEL) and Diacerein (DIA) in combined dosage form. Absorption correction method involves direct estimation of DIA at wavelength 341 nm in which CEL has zero absorbance and shows no interference. For estimation of CEL, corrected absorbance was calculated at 253 nm due to the interference of DIA at this wavelength. Linearity was observed in the range of 6-22 μg mL-1 for CEL and 3-11 μg mL-1 for DIA. The method was validated as per ICH guidelines. Chemometric methods including classical least square (CLS), inverse least square (ILS), principal component regression (PCR) and partial least square (PLS) were studied for simultaneous determination of CEL and DIA in capsule using spectrophotometry. A set of 25 standard mixtures containing both drugs were prepared in range of 5-25 μg mL-1 for CEL and 3-15 μg mL-1 for DIA. Analytical figure of merit (FOM), such as sensitivity, selectivity, analytical sensitivity, limit of detection and limit of quantitation were determined for chemometric methods. The proposed methods were applied for determination of two components from combined dosage form.

  13. Simultaneous spectrophotometric determination of celecoxib and diacerein in bulk and capsule by absorption correction method and chemometric methods.

    PubMed

    Patel, N S; Nandurbarkar, V P; Patel, A J; Patel, S G

    2014-05-01

    Two methods, absorption correction and multivariate spectrophotometric methods were developed for simultaneous estimation of Celecoxib (CEL) and Diacerein (DIA) in combined dosage form. Absorption correction method involves direct estimation of DIA at wavelength 341 nm in which CEL has zero absorbance and shows no interference. For estimation of CEL, corrected absorbance was calculated at 253 nm due to the interference of DIA at this wavelength. Linearity was observed in the range of 6-22 μg mL(-1) for CEL and 3-11 μg mL(-1) for DIA. The method was validated as per ICH guidelines. Chemometric methods including classical least square (CLS), inverse least square (ILS), principal component regression (PCR) and partial least square (PLS) were studied for simultaneous determination of CEL and DIA in capsule using spectrophotometry. A set of 25 standard mixtures containing both drugs were prepared in range of 5-25 μg mL(-1) for CEL and 3-15 μg mL(-1) for DIA. Analytical figure of merit (FOM), such as sensitivity, selectivity, analytical sensitivity, limit of detection and limit of quantitation were determined for chemometric methods. The proposed methods were applied for determination of two components from combined dosage form.

  14. Vaginal Absorption of Penicillin.

    PubMed

    Rock, J; Barker, R H; Bacon, W B

    1947-01-01

    Except during the last two months of pregnancy, penicillin is easily absorbed from cocoa butter suppositories in the vagina, ordinarily to give therapeutic blood levels for from 4 to 6 hours. Penicillin in the dosage used seems to have a good effect on vaginal infections. In nonpregnant women, during the ovulation phase, considered as including days 14 +/- 2 in the ordinary menstrual cycle of about 28 days, absorption seemed to be somewhat diminished. Higher levels were found in patients who were near the end of their menstrual cycles and in two patients who were menopausal. Patients who were very near term absorbed little or no penicillin, whereas patients 10 days post partum showed excellent absorption.

  15. Simultaneous determination of Cu 2+, Zn 2+, Cd 2+, Hg 2+ and Pb 2+ by using second-derivative spectrophotometry method

    NASA Astrophysics Data System (ADS)

    Han, Yanyan; Li, Yan; Si, Wei; Wei, Dong; Yao, Zhenxing; Zheng, Xianpeng; Du, Bin; Wei, Qin

    2011-09-01

    A new method of simultaneous determination of Cu 2+, Zn 2+, Cd 2+, Hg 2+ and Pb 2+ is proposed here by using the second-derivative spectrophotometry method. In pH = 10.35 Borax-NaOH buffer, using meso-tetra (3-methoxyl-4-hydroxylphenyl) porphyrin ([T-(3-MO-4-HP)P]) as chromomeric reagent, micelle solution was formed after Tween-80 surfactant was added into the solution containing Cu 2+, Zn 2+, Cd 2+, Hg 2+ and Pb 2+ ions. The original absorption spectrum of the above complexes was obtained after heating in the boiling water for 25 min. The second-derivative absorption peaks of five metal-porphyrin complexes can be separated from the original absorption spectrum by using chemometric tool. In this way, Cu 2+, Zn 2+, Cd 2+, Hg 2+ and Pb 2+ ions can be determined simultaneously. Under the optimal conditions, the linear ranges of the calibration curve were 0-0.60, 0-0.60, 0-0.40, 0-0.80 and 0-0.48 μg mL -1 for Cu 2+, Zn 2+, Cd 2+, Hg 2+ and Pb 2+, respectively. The molar absorptivity of these color systems were 1.38 × 10 5, 1.01 × 10 5, 3.24 × 10 5, 1.07 × 10 5 and 1.29 × 10 5 L mol -1 cm -1. The method developed in this paper has advantages in selectivity, sensitivity, operation and can effectively resolve spectra overlapping problem. This method has been applied to determine the real samples with satisfactory results.

  16. Sensitive determination of total particulate phosphorus and particulate inorganic phosphorus in seawater using liquid waveguide spectrophotometry.

    PubMed

    Ehama, Makoto; Hashihama, Fuminori; Kinouchi, Shinko; Kanda, Jota; Saito, Hiroaki

    2016-06-01

    Determining the total particulate phosphorus (TPP) and particulate inorganic phosphorus (PIP) in oligotrophic oceanic water generally requires the filtration of a large amount of water sample. This paper describes methods that require small filtration volumes for determining the TPP and PIP concentrations. The methods were devised by validating or improving conventional sample processing and by applying highly sensitive liquid waveguide spectrophotometry to the measurements of oxidized or acid-extracted phosphate from TPP and PIP, respectively. The oxidation of TPP was performed by a chemical wet oxidation method using 3% potassium persulfate. The acid extraction of PIP was initially carried out based on the conventional extraction methodology, which requires 1M HCl, followed by the procedure for decreasing acidity. While the conventional procedure for acid removal requires a ten-fold dilution of the 1M HCl extract with purified water, the improved procedure proposed in this study uses 8M NaOH solution for neutralizing 1M HCl extract in order to reduce the dilution effect. An experiment for comparing the absorbances of the phosphate standard dissolved in 0.1M HCl and of that dissolved in a neutralized solution [1M HCl: 8M NaOH=8:1 (v:v)] exhibited a higher absorbance in the neutralized solution. This indicated that the improved procedure completely removed the acid effect, which reduces the sensitivity of the phosphate measurement. Application to an ultraoligotrophic water sample showed that the TPP concentration in a 1075mL-filtered sample was 8.4nM with a coefficient of variation (CV) of 4.3% and the PIP concentration in a 2300mL-filtered sample was 1.3nM with a CV of 6.1%. Based on the detection limit (3nM) of the sensitive phosphate measurement and the ambient TPP and PIP concentrations of the ultraoligotrophic water, the minimum filtration volumes required for the detection of TPP and PIP were estimated to be 15 and 52mL, respectively.

  17. Sensitive determination of total particulate phosphorus and particulate inorganic phosphorus in seawater using liquid waveguide spectrophotometry.

    PubMed

    Ehama, Makoto; Hashihama, Fuminori; Kinouchi, Shinko; Kanda, Jota; Saito, Hiroaki

    2016-06-01

    Determining the total particulate phosphorus (TPP) and particulate inorganic phosphorus (PIP) in oligotrophic oceanic water generally requires the filtration of a large amount of water sample. This paper describes methods that require small filtration volumes for determining the TPP and PIP concentrations. The methods were devised by validating or improving conventional sample processing and by applying highly sensitive liquid waveguide spectrophotometry to the measurements of oxidized or acid-extracted phosphate from TPP and PIP, respectively. The oxidation of TPP was performed by a chemical wet oxidation method using 3% potassium persulfate. The acid extraction of PIP was initially carried out based on the conventional extraction methodology, which requires 1M HCl, followed by the procedure for decreasing acidity. While the conventional procedure for acid removal requires a ten-fold dilution of the 1M HCl extract with purified water, the improved procedure proposed in this study uses 8M NaOH solution for neutralizing 1M HCl extract in order to reduce the dilution effect. An experiment for comparing the absorbances of the phosphate standard dissolved in 0.1M HCl and of that dissolved in a neutralized solution [1M HCl: 8M NaOH=8:1 (v:v)] exhibited a higher absorbance in the neutralized solution. This indicated that the improved procedure completely removed the acid effect, which reduces the sensitivity of the phosphate measurement. Application to an ultraoligotrophic water sample showed that the TPP concentration in a 1075mL-filtered sample was 8.4nM with a coefficient of variation (CV) of 4.3% and the PIP concentration in a 2300mL-filtered sample was 1.3nM with a CV of 6.1%. Based on the detection limit (3nM) of the sensitive phosphate measurement and the ambient TPP and PIP concentrations of the ultraoligotrophic water, the minimum filtration volumes required for the detection of TPP and PIP were estimated to be 15 and 52mL, respectively. PMID:27130091

  18. Light absorption measurements: new techniques.

    PubMed

    Hänel, G; Busen, R; Hillenbrand, C; Schloss, R

    1982-02-01

    A new radiometer is described which simplifies measurement of the radiation supply of solar wavelengths. Two methods of measuring the radiant energy absorbed by aerosol particles are described: A photometric technique is used for particles collected on filters, and a calorimetric technique is used for in situ measurements. Data collected with the radiometer and the light absorption techniques yield the heating rate of the atmosphere due to light absorption by the particles. Sample measurements show substantial atmospheric temperature increases due to absorption, especially in industrial regions.

  19. [Light absorption by suspended particulate matter in Chagan Lake, Jilin].

    PubMed

    Wang, Yuan-Dong; Liu, Dian-Wei; Song, Kai-Shan; Zhang, Bai; Wang, Zong-Ming; Jiang, Guang-Ji; Tang, Xu-Guang; Lei, Xiao-Chun; Wu, Yan-Qing

    2011-01-01

    Spectral characteristics and the magnitudes of light absorption by suspended particulate matter were determined by spectrophotometry in this optically complex Lake Chagan waters for the purpose of surveying the natural variability of the absorption coefficients to parameterize the bio-optical models for converting satellite or in-situ water reflectance signatures into water quality information. Experiments were carried out on seasonal frozen Lake Chagan, one representative inland case-2 water body in Northeast of China. Particulate absorption properties analyzed using the field data on July 15th and October 12th 2009 were measured using the quantitative filter technique to produce absorption spectra containing several fractions that could be attributed to two main optical active constituents (OACs) phytoplankton pigments and non-algal particulates (mineral sediments, and organic detritus). Results suggested that the suspended particulate matter (SPM) concentration was higher while phytoplankton biomass (chlorophyll-a concentration) was lower in July and that in October. The spectral shape of total suspended particulate matter resembled that of non-algal particulates which contributed greater than phytoplankton in total particulate absorption during both periods. An obvious absorption peak occurring at around 440 nm exhibited an increase in phytoplankton contribution in October. Non-algal particulate absorption at 440 nm (a(NAP) (440)) had better correlation with total suspended particulate matter concentration than that with chlorophyll-a over the two periods. Light absorption by phytoplankton pigments in the Chagan lake region was generally lower than that of non-algal components. Chl. a dominating phytoplankton pigment composition functioned exponentially with its absorption coefficients at 440 and 675 nm specifically, the average values of which in July were 0.146 8 m2 x mg(-1) and 0.050 3 respectively while in October they were 0.153 3 and 0.013 2 m2 x mg(-1

  20. Absolute spectrophotometry in M31 and M32

    NASA Technical Reports Server (NTRS)

    Oke, J. B.; Schwarzschild, M.

    1974-01-01

    For a number of places in the bulge of M31 and for two places in M32 photometric scans from 3300 A to 10,600 A have been obtained with the multichannel spectrometer on the 5-meter Hale telescope. The scans show that in both objects the color temperature (particularly shortwards of 5000 A) decreases towards the center and that the strength of the CN bands increases towards the center in both objects in agreement with earlier observations. The new data can all be interpreted in terms of an increase of heavy element abundance towards the center in both objects by a factor probably less than 2 and by an excess of heavy elements in M31 compared to M32 by a factor probably greater than 2, in qualitative agreement with earlier conclusions.

  1. Optical spectrophotometry of oscillations and flickering in AE Aquarii

    NASA Technical Reports Server (NTRS)

    Welsh, William F.; Horne, Keith; Oke, J. B.

    1993-01-01

    We observed rapid variations in the nova-like cataclysmic variable AE Aquarii for 1.7 hr with 4.3 s time resolution using the 30-channel (3227-10494 A) spectrophotometer on the Hale 5 m telescope. The 16.5 and 33.0 s oscillations show a featureless blue spectrum that can be represented by a blackbody with temperature and area much smaller than the accretion disk. Models consisting of the sum of a K star spectrum and a hydrogen slab in LTE at T = 6000-10,000 K can fit the spectrum of AE Aquarii reasonably well. The spectrum of a flare indicates optically thin gas with T = 8000-12,000 K. The energy released by the flare is large compared to typical stellar flares.

  2. Spectrophotometry of Epsilon Aur, 3295-8880 A

    NASA Technical Reports Server (NTRS)

    Lockwood, G. W.; Thompson, D. T.; Lutz, B. L.; Sowell, J.

    1985-01-01

    Spectrophotometric scans were obtained at 8 A resolution from 3295 to 8880 A on twenty nights before, during, and after the recent eclipse of epsilon Aurigae, beginning with a pre-eclipse observation on 5 March 1982 U.T. The observations were reduced to absolute flux using the standard stars 109 Vir or xi(2) Ceti. The data confirm that the eclipse is essentially gray over the entire visible spectrum, as others have noted from broadband photometry. High resolution echellograms (450 to 6700 A) made through mid-eclipse and the scans show changes in the equivalent widths of H alpha, Na D, and O I as large as a factor of two.

  3. Spectrophotometry of Bowen resonance fluorescence lines in three planetary nebulae

    NASA Technical Reports Server (NTRS)

    O'Dell, C. R.; Miller, Christopher O.

    1992-01-01

    The results are presented of a uniquely complete, carefully reduced set of observations of the O III Bowen fluorescence lines in the planetary nebulae NGC 6210, NGC 7027, and NGC 7662. A detailed comparison with the predictions of radiative excitation verify that some secondary lines are enhanced by selective population by the charge exchange mechanism involving O IV. Charge exchange is most important in NGC 6210, which is of significantly lower ionization than the other nebulae. In addition to the principal Bowen lines arising from Ly-alpha pumping of the O III O1 line, lines arising from pumping of the O3 line are also observed. Comparison of lines produced by O1 and O3 with the theoretical predictions of Neufeld indicate poor agreement; comparison with the theoretical predictions of Harrington show agreement with NGC 7027 and NGC 7662.

  4. Two-phase ultraviolet spectrophotometry of the pulsating white dwarf ZZ Piscium

    NASA Technical Reports Server (NTRS)

    Bond, H. E.; Kemper, E.; Grauer, A. D.; Holm, A. V.; Panek, R. J.; Schiffer, F. H., III

    1985-01-01

    Spectra of the pulsating white dwarf ZZ Psc (= G29-38) were obtained using the International Ultraviolet Explorer. By using a multiple-exposure technique in conjunction with simultaneous ground-based exposure-metering photometry, it was possible to obtain mean on-pulse and off-pulse spectra in the 1950-1310 A wavelength range. The ratio of the time-averaged on-pulse to off-pulse spectra is best fitted by a temperature variation that is in phase with the optical light variation. This result is consistent with the hypothesis that the observed variation is due to a high-order nonradial pulsation. Conventional ultraviolet spectra of ZZ Psc showed broad absorption features at 1390 and 1600 A. These features are also found in the spectra of the cool DA-type white dwarfs G226-29 and G67-23, and appear to increase in strength with decreasing temperature. A possible explanation for the 1600 A feature is absorption by the satellite band of resonance-broadened hydrogen Ly-alpha. Such absorption would also help explain a discrepancy between the observed pulsation amplitude shortward of 1650 A and the predicted amplitudes based on model atmospheres.

  5. Spectrophotometry of Dust in Comet Hale-Bopp

    NASA Technical Reports Server (NTRS)

    Witteborn, Fred C. (Technical Monitor)

    1997-01-01

    Comets, such as Hale-Bopp (C/1995 O1), are frozen reservoirs of primitive solar nebula dust grains and ices. Analysis of the composition of cometary dust grains from infrared spectroscopic techniques permits an estimation of the types of organic and inorganic materials that constituted the early primitive solar nebula. In addition, the cometary bombardment of the Earth (approximately 3.5 Gy ago) supplied the water for the oceans and brought organic materials to Earth which may have been biogenic. Spectroscopic observations of comet Hale-Bopp suggest the possible presence of organic hydrocarbon species, silicate and olivine dust grains, and water ice. Spectroscopy near 3 microns obtained in Nov 1996 r=2.393 AU, delta=3.034 AU) shows a feature which we attribute to PAH emission. The spatial morphology of the 3.28 microns PAH feature is also presented. Optical and infrared spectrophotometric observations of comets convey valuable information about the spatial distribution and properties of dust and gas within the inner coma. In the optical and NIR shortward of 2 microns, the observed light is primarily scattered sunlight from the dust grains. At longer wavelengths, particularly in the 10 gm window, thermal emission from these grains dominates the radiation allowing an accurate estimate of grain sizes and chemical composition. Here we present an initial analysis of spectra taken with the NASA HIFOGS at 7-14 microns as part of a multiwavelength temporal study of the "comet of the century".

  6. Improved optical spectrophotometry of supernova remnants in M33

    NASA Technical Reports Server (NTRS)

    Blair, W. P.; Kirshner, R. P.

    1985-01-01

    Optical spectra of SNRs in M33 have been used to investigate abundance gradients and SNR evolution in this galaxy. Abundances of O, N, and S are derived from the spectra using new shock models by Dopita et al. (1984). The results for N and S show abundance gradients similar to those in NGC 300 and the Galaxy. The O abundances may be affected by possible contamination from H II regions and low-velocity shocks. Electron densities derived from the forbidden S II 6717 A/6731 A line ratio are used with a pressure equilibrium argument to estimate the initial explosion energy for each SNR. Evolutionary models for the remnants are investigated, and the distribution of the number of remnants with diameter is found to be consistent with free expansion of the SNRs to diameters of about 26 pc. The results may also be consistent with Sedov evolution if the ranges of initial supernova energies and surrounding interstellar medium densities are large enough.

  7. Spectrophotometry and organic matter on Iapetus. 1: Composition models

    NASA Technical Reports Server (NTRS)

    Wilson, Peter D.; Sagan, Carl

    1995-01-01

    Iapetus shows a greater hemispheric albedo asymmetry than any other body in the solar system. Hapke scattering theory and optical constants measured in the laboratory are used to identify possible compositions for the dark material on the leading hemisphere of Iapetus. The materials considered are poly-HCN, kerogen, Murchison organic residue, Titan tholin, ice tholin, and water ice. Three-component mixtures of these materials are modeled in intraparticle mixture of 25% poly-HCN, 10% Murchison residue, and 65% water ice is found to best fit the spectrum, albedo, and phase behavior of the dark material. The Murchison residue and/or water ice can be replaced by kerogen and ice tholin, respectively, and still produce very good fits. Areal and particle mixtures of poly-HCN, Titan tholin, and either ice tholin or Murchison residue are also possible models. Poly-HCN is a necessary component in almost all good models. The presence of poly-HCN can be further tested by high-resolution observations near 4.5 micrometers.

  8. Objective evaluation by reflectance spectrophotometry can be of clinical value for the verification of blanching/non blanching erythema in the sacral area.

    PubMed

    Sterner, Eila; Fossum, Bjöörn; Berg, Elisabeth; Lindholm, Christina; Stark, André

    2014-08-01

    Early detection of non blanching erythema (pressure ulcer category I) is necessary to prevent any further skin damage. An objective method to discriminate between blanching/non blanching erythema is presently not available. The purpose of this investigation was to explore if a non invasive objective method could differentiate between blanching/non blanching erythema in the sacral area of patients undergoing hip fracture surgery. Seventy-eight patients were included. The sacral area of all patients was assessed using (i) conventional finger-press test and (ii) digital reading of the erythema index assessed with reflectance spectrophotometry. The patients were examined at admission and during 5 days postsurgery. Reflectance spectrophotometry measurements proved able to discriminate between blanching/non blanching erythema. The reliability, quantified by the intra-class correlation coefficient, was excellent between repeated measurements over the measurement period, varying between 0·82 and 0·96, and a significant change was recorded in the areas from day 1 to day 5 (P < 0·0001). The value from the reference point did not show any significant changes over the same period (P = 0·32). An objective method proven to identify early pressure damage to tissue can be a valuable tool in clinical practice.

  9. Formaldehyde in Alcoholic Beverages: Large Chemical Survey Using Purpald Screening Followed by Chromotropic Acid Spectrophotometry with Multivariate Curve Resolution

    PubMed Central

    Jendral, Julien A.; Monakhova, Yulia B.; Lachenmeier, Dirk W.

    2011-01-01

    A strategy for analyzing formaldehyde in beer, wine, spirits, and unrecorded alcohol was developed, and 508 samples from worldwide origin were analyzed. In the first step, samples are qualitatively screened using a simple colorimetric test with the purpald reagent, which is extremely sensitive for formaldehyde (detection limit 0.1 mg/L). 210 samples (41%) gave a positive purpald reaction. In the second step, formaldehyde in positive samples is confirmed by quantitative spectrophotometry of the chromotropic acid-formaldehyde derivative combined with Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS). Calculation of UV-VIS and 13C NMR spectra confirmed the monocationic dibenzoxanthylium structure as the product of the reaction and disproved the widely cited para,para-quinoidal structure. Method validation for the spectrophotometric procedure showed a detection limit of 0.09 mg/L and a precision of 4.2–8.2% CV. In total, 132 samples (26%) contained formaldehyde with an average of 0.27 mg/L (range 0–14.4 mg/L). The highest incidence occurred in tequila (83%), Asian spirits (59%), grape marc (54%), and brandy (50%). Our survey showed that only 9 samples (1.8%) had formaldehyde levels above the WHO IPCS tolerable concentration of 2.6 mg/L. PMID:21760790

  10. The H-band emitting region of the luminous blue variable P Cygni: Spectrophotometry and interferometry of the wind

    SciTech Connect

    Richardson, N. D.; Gies, D. R.; Baron, F.; Parks, J. R.; Matson, R. A.; Touhami, Y.; Aldoretta, E. J.; McAlister, H. A.; Schaefer, G. H.; Ten Brummelaar, T. A.; Sturmann, J.; Sturmann, L.; Chesneau, O.; Monnier, J. D.; Che, X.; Clemens, D. P.; Taylor, B.; Morrison, N. D.; Kraus, S.; Ridgway, S. T.; and others

    2013-06-01

    We present the first high angular resolution observations in the near-infrared H band (1.6 μm) of the luminous blue variable star P Cygni. We obtained six-telescope interferometric observations with the CHARA Array and the MIRC beam combiner. These show that the spatial flux distribution is larger than expected for the stellar photosphere. A two-component model for the star (uniform disk) plus a halo (two-dimensional Gaussian) yields an excellent fit of the observations, and we suggest that the halo corresponds to flux emitted from the base of the stellar wind. This wind component contributes about 45% of the H-band flux and has an angular FWHM = 0.96 mas, compared to the predicted stellar diameter of 0.41 mas. We show several images reconstructed from the interferometric visibilities and closure phases, and they indicate a generally spherical geometry for the wind. We also obtained near-infrared spectrophotometry of P Cygni from which we derive the flux excess compared to a purely photospheric spectral energy distribution. The H-band flux excess matches that from the wind flux fraction derived from the two-component fits to the interferometry. We find evidence of significant near-infrared flux variability over the period from 2006 to 2010 that appears similar to the variations in the Hα emission flux from the wind.

  11. Optical absorption characteristics of polycrystalline AgGaSe2 thin films

    NASA Astrophysics Data System (ADS)

    Bhuiyan, M. R. A.; Firoz Hasan, S. M.

    2006-12-01

    Silver gallium di-selenide (AgGaSe2) composite thin films have been formed onto ultrasonically and chemically cleaned glass substrates by in situ thermal annealing of the stack of successively evaporated individual elemental layers in vacuum. The structural properties of the films were ascertained by the x-ray diffraction method. The diffractogram indicated that these films were polycrystalline in nature having tetragonal structure with lattice parameters, a ap 6.00 Å and c ap 10.92 Å and average grain dimension 40 nm. The optical properties and atomic compositions of the films have been determined by UV-VIS-NIR spectrophotometry (photon wavelength ranging between 300 and 2500 nm) and energy dispersive analysis of x-ray, respectively. The typical optical absorption characteristic of the films has been critically analysed. The optical absorption coefficients vary from 103 to 105 cm-1 in the measured wavelength range of photons. The films have more than one type of fundamental electronic transitions. Direct allowed and direct forbidden transitions vary from 1.628 to 1.748 eV and 2.077 to 2.193 eV, respectively, depending on the composition of the films. The former transitions are found to have a general tendency to be symmetric around non-molecularity ΔX = 0, defined by ΔX = [(Ag/Ga)] - 1, while the latter shows no such dependence. Stoichiometric or slightly silver-deficient films show electron transition energies closer to the single crystal value. Spin-orbit splitting of the valence band becomes minimum at perfect stoichiometry.

  12. Television Quiz Show Simulation

    ERIC Educational Resources Information Center

    Hill, Jonnie Lynn

    2007-01-01

    This article explores the simulation of four television quiz shows for students in China studying English as a foreign language (EFL). It discusses the adaptation and implementation of television quiz shows and how the students reacted to them.

  13. Incomplete intestinal absorption of fructose.

    PubMed

    Kneepkens, C M; Vonk, R J; Fernandes, J

    1984-08-01

    Intestinal D-fructose absorption in 31 children was investigated using measurements of breath hydrogen. Twenty five children had no abdominal symptoms and six had functional bowel disorders. After ingestion of fructose (2 g/kg bodyweight), 22 children (71%) showed a breath hydrogen increase of more than 10 ppm over basal values, indicating incomplete absorption: the increase averaged 53 ppm, range 12 to 250 ppm. Four of these children experienced abdominal symptoms. Three of the six children with bowel disorders showed incomplete absorption. Seven children were tested again with an equal amount of glucose, and in three of them also of galactose, added to the fructose. The mean maximum breath hydrogen increases were 5 and 10 ppm, respectively, compared with 103 ppm after fructose alone. In one boy several tests were performed with various sugars; fructose was the only sugar incompletely absorbed, and the effect of glucose on fructose absorption was shown to be dependent on the amount added. It is concluded that children have a limited absorptive capacity for fructose. We speculate that the enhancing effect of glucose and galactose on fructose absorption may be due to activation of the fructose carrier. Apple juice in particular contains fructose in excess of glucose and could lead to abdominal symptoms in susceptible children.

  14. Incomplete intestinal absorption of fructose.

    PubMed Central

    Kneepkens, C M; Vonk, R J; Fernandes, J

    1984-01-01

    Intestinal D-fructose absorption in 31 children was investigated using measurements of breath hydrogen. Twenty five children had no abdominal symptoms and six had functional bowel disorders. After ingestion of fructose (2 g/kg bodyweight), 22 children (71%) showed a breath hydrogen increase of more than 10 ppm over basal values, indicating incomplete absorption: the increase averaged 53 ppm, range 12 to 250 ppm. Four of these children experienced abdominal symptoms. Three of the six children with bowel disorders showed incomplete absorption. Seven children were tested again with an equal amount of glucose, and in three of them also of galactose, added to the fructose. The mean maximum breath hydrogen increases were 5 and 10 ppm, respectively, compared with 103 ppm after fructose alone. In one boy several tests were performed with various sugars; fructose was the only sugar incompletely absorbed, and the effect of glucose on fructose absorption was shown to be dependent on the amount added. It is concluded that children have a limited absorptive capacity for fructose. We speculate that the enhancing effect of glucose and galactose on fructose absorption may be due to activation of the fructose carrier. Apple juice in particular contains fructose in excess of glucose and could lead to abdominal symptoms in susceptible children. PMID:6476870

  15. Effective absorption in cladding-pumped fibers

    NASA Astrophysics Data System (ADS)

    Zervas, Michalis N.; Marshall, Andy; Kim, Jaesun

    2011-02-01

    We investigate experimentally and theoretically the wavelength dependence of the pump absorption along Yb3+-doped fibers, for cladding-pumped single as well as coupled multimode (GTWaveTM) fibers. We show that significant spectral absorption distortions occur along the length with the 976nm absorption peak affected the most. We have developed a novel theoretical approach, based on coupled mode theory, to explain the observed effects. We have also investigated the mode mixing requirements in order to improve the absorption spectral distribution along the increase the overall absorption efficiency and discuss the implications on fiber laser performance.

  16. Simultaneous determination of carminic acid, riboflavine, curcumin and erythrosine by derivative spectrophotometry and ratio spectra derivative.

    PubMed

    Nevado, J J; Cabanillas, C G; Salcedo, A M

    1994-05-01

    A quaternary mixture of carminic acid, riboflavine, curcumin and erythrosine can be resolved with a previous extraction step into metyl-isobutyl ketone and, resolving the binary mixtures obtained in the aqueous phase and organic phase, using derivative spectrophotometry on the basis of the zero-crossing measurements in the first derivative spectra as well as the first derivative of ratio spectra. The conditions of extraction established and the proposed methods have been tested to determine these colorants in several synthetic mixtures of four dyes, obtaining good recoveries. The methods have been applied in yoghurt samples spiked with the dyes. PMID:18966000

  17. Absolute spectrophotometry of Wolf-Rayet stars from 1200 to 7000 A - A cautionary tale

    NASA Technical Reports Server (NTRS)

    Garmany, C. D.; Conti, P. S.; Massey, P.

    1984-01-01

    It is demonstrated that absolute spectrophotometry of the continua of Wolf-Rayet stars may be obtained over the wavelength range 1200-7000 A using IUE and optical measurements. It is shown that the application of a 'standard' reddening law to the observed data gives spurious results in many cases. Additional UV extinction is apparently necessary and may well be circumstellar in origin. In such hot stars, the long-wavelength 'tail' of the emergent stellar continuum are measured. The inadequacy of previous attempts to determine intrinsic continua and effective temperatures of Wolf-Rayet stars is pointed out.

  18. Self-scanned photodiode array - High performance operation in high dispersion astronomical spectrophotometry

    NASA Technical Reports Server (NTRS)

    Vogt, S. S.; Tull, R. G.; Kelton, P.

    1978-01-01

    A multichannel spectrophotometric detector system has been developed using a 1024 element self-scanned silicon photodiode array, which is now in routine operation with the high-dispersion coude spectrograph of the University of Texas McDonald Observatory 2.7-m telescope. Operational considerations in the use of such arrays for high precision and low light level spectrophotometry are discussed. A detailed description of the system is presented. Performance of the detector as measured in the laboratory and on astronomical program objects is described, and it is shown that these arrays are highly effective detectors for high dispersion astronomical spectroscopy.

  19. A straightforward ninhydrin-based method for collagenase activity and inhibitor screening of collagenase using spectrophotometry.

    PubMed

    Zhang, Yanfang; Fu, Yun; Zhou, Sufeng; Kang, Lixia; Li, Changzheng

    2013-06-01

    Currently protease assay kits, requiring substrate that is either radiolabeled or fluorescence labeled and specialized instruments, are all expensive. A simple, reliable assay of protease activity and its inhibitor screening for general laboratory is rare. Here we demonstrated a straightforward ninhydrin-based method for assay of collagenase activity and its inhibitor screening using spectrophotometry. In the method, without multistep sample treatments and substrate labeling, the hydrolytic products were directly traced by ninhydrin. The method is expected to be suitable for not only the assay of collagenase activity but also the others matrix metalloproteinases activities, and can be used for kinetic study.

  20. The spectrophotometry and chemical composition of the oxygen-poor bipolar nebula NGC 6164-5

    NASA Technical Reports Server (NTRS)

    Dufour, Reginald J.; Parker, Robert A. R.; Henize, Karl G.

    1988-01-01

    The paper presents new ground-based and IUE spectrophotometry of several positions in NGC 6164-5 surrounding the Population I Of star HD 148937. Electron temperatures, densities, and abundances are derived for the various positions in the nebula using spectral line information. For all of the regions observed, Ne/H is depleted by an amount comparable to O/H, while S/H and Ar/H have normal values. The results suggest that the nebula consists partly of material ejected from inner shell-burning regions of the Of star. In effect, HD 148937 is older and more advanced than what was previously thought.

  1. Near-infrared and ultraviolet spectrophotometry of the young planetary nebula Hubble 12

    NASA Technical Reports Server (NTRS)

    Rudy, Richard J.; Rossano, George S.; Erwin, Peter; Puetter, R. C.; Feibelman, Walter A.

    1993-01-01

    The young planetary nebula Hubble 12 is observed using near-IR and UV spectrophotometry. The brightness of the O I lines, which is greater than in any other planetary nebula yet measured, indicates that fluorescent excitation by stellar continuum is the principal mechanism generating these lines. Extinction, electron density, and electron temperature are determined using infrared measurements combined with UV data and published optical observations. The range in extinction, density, and temperature implies that, within the ionized region, pockets of emission with distinctly different conditions exist. Logarithmic abundances for helium, oxygen, and sulfur are presented.

  2. 8- to 13-micron spectrophotometry of Comet IRAS-Araki-Alcock

    NASA Technical Reports Server (NTRS)

    Feierberg, M. A.; Witteborn, F. C.; Johnson, J. R.; Campins, H.

    1984-01-01

    Spectrophotometry between 8.0 and 13.0 microns at 2 percent spectral resolution is presented for areas in and near the nuclear condensation of Comet IRAS-Araki-Alcock (1983d) on May 11 and 12, 1983. All the spectra can be fit very well by blackbody curves, and no 10-micron silicate emissions are seen. The temperature structure of the coma suggests the presence of small (radii less than 5 microns) dust particles within 150 km of the nucleus and larger ones further out. The change in the spatial distribution of the infrared flux between the two nights suggests that an outburst may have occurred sometime on May 11.

  3. 2.7- to 4.1-micron spectrophotometry of icy satellites of Saturn and Jupiter

    NASA Technical Reports Server (NTRS)

    Lebofsky, L. A.; Feierberg, M. A.

    1985-01-01

    Spectrophotometry is presented in the 2.7-4.1 micrometer spectral region for icy satellites of Saturn (Tethys, Dione, Rhea, Iapetus and Hyperion) and Jupiter (Europa, Ganymede and Callisto). The 3.6-micrometer reflectance peak characteristic of fine-grained water ice is observed prominently on the satellites of Saturn, faintly on the leading side of Europa, and not at all on Ganymede, Callisto or the dark side of Iapetus. The spectral reflectances of these icy satellites may be affected by their equilibrium surface temperatures and magnetospheric effects.

  4. UV-visible scanning spectrophotometry and chemometric analysis as tools for carotenoids analysis in cassava genotypes (Manihot esculenta Crantz).

    PubMed

    Moresco, Rodolfo; Uarrota, Virgílio Gavicho; Pereira, Aline; Tomazzoli, Maíra Maciel; Nunes, Eduardo da C; Peruch, Luiz Augusto Martins; Gazzola, Jussara; Costa, Christopher; Rocha, Miguel; Maraschin, Marcelo

    2015-10-21

    In this study, the metabolomics characterization focusing on the carotenoid composition of ten cassava (Manihot esculenta) genotypes cultivated in southern Brazil by UV-visible scanning spectrophotometry and reverse phase-high performance liquid chromatography was performed. Cassava roots rich in β-carotene are an important staple food for populations with risk of vitamin A deficiency. Cassava genotypes with high pro-vitamin A activity have been identified as a strategy to reduce the prevalence of deficiency of this vitamin. The data set was used for the construction of a descriptive model by chemometric analysis. The genotypes of yellow-fleshed roots were clustered by the higher concentrations of cis-β-carotene and lutein. Inversely, cream-fleshed roots genotypes were grouped precisely due to their lower concentrations of these pigments, as samples rich in lycopene (red-fleshed) differed among the studied genotypes. The analytical approach (UV-Vis, HPLC, and chemometrics) used showed to be efficient for understanding the chemodiversity of cassava genotypes, allowing to classify them according to important features for human health and nutrition.

  5. Comparison of three methods of DNA extraction in endocervical specimens for Chlamydia trachomatis infection by spectrophotometry, agarose gel, and PCR.

    PubMed

    Jenab, Anahita; Roghanian, Rasoul; Golbang, Naser; Golbang, Pouran; Chamani-Tabriz, Leili

    2010-06-01

    Chlamydia trachomatis is the major cause of sexually transmitted disease in the world. The aim of this study was to determine the best method of DNA extraction for detecting C. trachomatis by polymerase chain reaction (PCR) in sexually active women (n = 80) attending Shahid Beheshti Hospital in Isfahan, Iran. Endocervical swabs were collected from 80 women, 22 of whom were asymptomatic and 58 symptomatic. Three different DNA extraction methods were used in this study (phenol-chlorophorm, proteinase K, and boiling). DNA yield was evaluated by spectrophotometry, agarose gel, and PCR. The internal control was assayed by beta-globin primers (PCO4, GH20). The DNA cryptic plasmid was selected as the target for C. trachomatis and samples were examined by PCR using specific KL1 and KL2 primers. It was shown that DNA extraction by boiling was the most sensitive with the highest yield of DNA. Of the 80 samples, 17 (21.25%) showed positivity for C. trachomatis by PCR. The highest rate of C. trachomatis infection was found in the group aged between 35 and 45 years old and those who used withdrawal or an intrauterine device as methods of contraception. It was demonstrated that DNA extraction by boiling was the least expensive and a very rapid method that gave the highest DNA yield. The infection rate in the sexually active women, including symptomatic and asymptomatic, was 21.25%, with a presumably high prevalence compared with other studies done in this field.

  6. Fat-soluble vitamin intestinal absorption: absorption sites in the intestine and interactions for absorption.

    PubMed

    Goncalves, Aurélie; Roi, Stéphanie; Nowicki, Marion; Dhaussy, Amélie; Huertas, Alain; Amiot, Marie-Josèphe; Reboul, Emmanuelle

    2015-04-01

    The interactions occurring at the intestinal level between the fat-soluble vitamins A, D, E and K (FSVs) are poorly documented. We first determined each FSV absorption profile along the duodenal-colonic axis of mouse intestine to clarify their respective absorption sites. We then investigated the interactions between FSVs during their uptake by Caco-2 cells. Our data show that vitamin A was mostly absorbed in the mouse proximal intestine, while vitamin D was absorbed in the median intestine, and vitamin E and K in the distal intestine. Significant competitive interactions for uptake were then elucidated among vitamin D, E and K, supporting the hypothesis of common absorption pathways. Vitamin A also significantly decreased the uptake of the other FSVs but, conversely, its uptake was not impaired by vitamins D and K and even promoted by vitamin E. These results should be taken into account, especially for supplement formulation, to optimise FSV absorption.

  7. A Holographic Road Show.

    ERIC Educational Resources Information Center

    Kirkpatrick, Larry D.; Rugheimer, Mac

    1979-01-01

    Describes the viewing sessions and the holograms of a holographic road show. The traveling exhibits, believed to stimulate interest in physics, include a wide variety of holograms and demonstrate several physical principles. (GA)

  8. Infrared absorption mechanisms of black silicon

    NASA Astrophysics Data System (ADS)

    Cheng, Zhengxi; Chen, Yongping; Ma, Bin

    2014-09-01

    Black silicon has a wide spectrum of non-spectral characteristics high absorption from visible to long wave infrared band .Based on semi-empirical impurity band model, free carrier absorption, radiation transitions between the valence band and the impurity band, radiation transitions between the impurity band and the conduction band were calculated, and absorption coefficients for each process were got. The results showed that the transitions from valence band to the impurity band induced absorption in the near-infrared waveband, but it has a rapid decay with wavelength. In the shortwave mid-wave and long-wave IR bands, transitions from the impurity band to the conduction band caused a huge absorption, and the absorption coefficient was slowly decreased with increasing wavelength. The free carrier absorption dominates in long-wave band. The calculation results agreed well with the test results of plant black silicon in magnitude and trends.

  9. Preparation of Ion Exchange Films for Solid-Phase Spectrophotometry and Solid-Phase Fluorometry

    NASA Technical Reports Server (NTRS)

    Hill, Carol M.; Street, Kenneth W.; Tanner, Stephen P.; Philipp, Warren H.

    2000-01-01

    Atomic spectroscopy has dominated the field of trace inorganic analysis because of its high sensitivity and selectivity. The advantages gained by the atomic spectroscopies come with the disadvantage of expensive and often complicated instrumentation. Solid-phase spectroscopy, in which the analyte is preconcentrated on a solid medium followed by conventional spectrophotometry or fluorometry, requires less expensive instrumentation and has considerable sensitivity and selectivity. The sensitivity gains come from preconcentration and the use of chromophore (or fluorophore) developers and the selectivity is achieved by use of ion exchange conditions that favor the analyte in combination with speciative chromophores. Little work has been done to optimize the ion exchange medium (IEM) associated with these techniques. In this report we present a method for making ion exchange polymer films, which considerably simplify the solid-phase spectroscopic techniques. The polymer consists of formaldehyde-crosslinked polyvinyl alcohol with polyacrylic acid entrapped therein. The films are a carboxylate weak cation exchanger in the calcium form. They are mechanically sturdy and optically transparent in the ultraviolet and visible portion of the spectrum, which makes them suitable for spectrophotometry and fluorometry.

  10. Feature selection versus feature compression in the building of calibration models from FTIR-spectrophotometry datasets.

    PubMed

    Vergara, Alexander; Llobet, Eduard

    2012-01-15

    Undoubtedly, FTIR-spectrophotometry has become a standard in chemical industry for monitoring, on-the-fly, the different concentrations of reagents and by-products. However, representing chemical samples by FTIR spectra, which spectra are characterized by hundreds if not thousands of variables, conveys their own set of particular challenges because they necessitate to be analyzed in a high-dimensional feature space, where many of these features are likely to be highly correlated and many others surely affected by noise. Therefore, identifying a subset of features that preserves the classifier/regressor performance seems imperative prior any attempt to build an appropriate pattern recognition method. In this context, we investigate the benefit of utilizing two different dimensionality reduction methods, namely the minimum Redundancy-Maximum Relevance (mRMR) feature selection scheme and a new self-organized map (SOM) based feature compression, coupled to regression methods to quantitatively analyze two-component liquid samples utilizing FTIR spectrophotometry. Since these methods give us the possibility of selecting a small subset of relevant features from FTIR spectra preserving the statistical characteristics of the target variable being analyzed, we claim that expressing the FTIR spectra by these dimensionality-reduced set of features may be beneficial. We demonstrate the utility of these novel feature selection schemes in quantifying the distinct analytes within their binary mixtures utilizing a FTIR-spectrophotometer.

  11. Use of reflectance spectrophotometry to predict the response of port wine stains to pulsed dye laser.

    PubMed

    Halachmi, Shlomit; Azaria, Ron; Inbar, Roy; Ad-El, Dean; Lapidoth, Moshe

    2014-01-01

    Reflectance spectroscopy can be used to quantitate subtle differences in color. We applied a portable reflectance spectrometer to determine its utility in the evaluation of pulsed dye laser treatment of port wine stains (PWS) and in prediction of clinical outcome, in a prospective study. Forty-eight patients with PWS underwent one to nine pulsed dye laser treatments. Patient age and skin color as well as PWS surface area, anatomic location, and color were recorded. Pretreatment spectrophotometric measurements were performed. The subjective clinical results of treatment and the quantitative spectrophotometry results were evaluated by two independent teams, and the findings were correlated. The impact of the clinical characteristics on the response to treatment was assessed as well. Patients with excellent to good clinical results of laser treatments had pretreatment spectrophotometric measurements which differed by more than 10%, whereas patients with fair to poor results had spectrophotometric measurements with a difference of of less than 10%. The correlation between the spectrophotometric results and the clinical outcome was 73% (p < 0.01). The impact of the other clinical variables on outcome agreed with the findings in the literature. Spectrophotometry has a higher correlation with clinical outcome and a better predictive value than other nonmeasurable, nonquantitative, dependent variables.

  12. Combination of solid phase extraction and dispersive liquid-liquid microextraction for separation/preconcentration of ultra trace amounts of uranium prior to its fiber optic-linear array spectrophotometry determination.

    PubMed

    Dadfarnia, Shayessteh; Shabani, Ali Mohammad Haji; Shakerian, Farid; Shiralian Esfahani, Golnaz

    2013-12-15

    A simple and sensitive method for the separation and preconcentration of the ultra trace amounts of uranium and its determination by spectrophotometry was developed. The method is based on the combination of solid phase extraction and dispersive liquid-liquid microextraction. Thus, by passing the sample through the basic alumina column, the uranyl ion and some cations are separated from the sample matrix. The retained uranyl ion along with the cations are eluted with 5 mL of nitric acid (2 mol L(-1)) and after neutralization of the eluent, the extracted uranyl ion is converted to its anionic benzoate complex and is separated from other cations by extraction of its ion pair with malachite green into small volume of chloroform using dispersive liquid-liquid microextraction. The amount of uranium is then determined by the absorption measurement of the extracted ion pair at 621 nm using flow injection spectrophotometry. Under the optimum conditions, with 500 mL of the sample, a preconcentration factor of 1980, a detection limit of 40 ng L(-1), and a relative standard deviation of 4.1% (n=6) at 400 ng L(-1) were obtained. The method was successfully applied to the determination of uranium in mineral water, river water, well water, spring water and sea water samples.

  13. Interactions of praseodymium and neodymium with nucleosides and nucleotides: absorption difference and comparative absorption spectral study.

    PubMed

    Misra, S N; Anjaiah, K; Joseph, G; Abdi, S H

    1992-02-01

    The interactions of praseodymium(III) and neodymium(III) with nucleosides and nucleotides have been studied in different stoichiometry in water and water-DMF mixtures by employing absorption difference and comparative absorption spectrophotometry. The 4f-4f bands were analysed by linear curve analysis followed by gaussian curve analysis, and various spectral parameters were computed, using partial and multiple regression method. The magnitude of changes in both energy interaction and intensity were used to explore the degree of outer and inner sphere coordination, incidence of covalency and the extent of metal 4f-orbital involvement in chemical bonding. Crystalline complexes of the type [Ln(nucleotide)2(H2O)2]- (where nucleotide--GMP or IMP) were characterized by IR, 1H NMR, 31P NMR data. These studies indicated that the binding of the nucleotide is through phosphate oxygen in a bidentate manner and the complexes undergo substantial ionisation in aqueous medium, thereby supporting the observed weak 4f-4f bands and lower values for nephelauxetic effect (1-beta), bonding (b) and covalency (delta) parameters derived from coulombic and spin orbit interaction parameters.

  14. In vitro study of percutaneous absorption of aluminum from antiperspirants through human skin in the Franz™ diffusion cell.

    PubMed

    Pineau, Alain; Guillard, Olivier; Favreau, Frédéric; Marty, Marie-Hélène; Gaudin, Angeline; Vincent, Claire Marie; Marrauld, Annie; Fauconneau, Bernard; Marty, Jean-Paul

    2012-05-01

    Aluminum salts such as aluminum chlorohydrate (ACH) are known for use as an active antiperspirant agent that blocks the secretion of sweat. A local case report of hyperaluminemia in a woman using an aluminum-containing antiperspirant for 4 years raises the problem of transdermal absorption of aluminum (Al). Only a very limited number of studies have shown that the skin is an effective barrier to transdermal uptake of Al. In accordance with our analytical procedure, the aim of this study with an in vitro Franz™ diffusion cell was to measure aluminum uptake from three cosmetic formulations of antiperspirant: the base for an "aerosol" (38.5% of ACH), a "roll-on" emulsion (14.5% ACH), and a "stick" (21.2%), by samples of intact and stripped human skin (5 donors). The Al assays were performed by Zeeman Electrothermal Atomic Absorption Spectrophotometry (ZEAAS). Following contacts lasting 6, 12 and 24h, the Al assays showed only insignificant transdermal absorption of Al (≤0.07% of the quantity of Al deposited) and particularly low cutaneous quantities that varied according to the formulations (1.8 μg/cm² for "aerosol base" and "stick" - 0.5 μg/cm² for the "roll-on"). On stripped skin, for which only the "stick" formulation was tested, the measured uptake was significantly higher (11.50 μg/cm² versus 1.81 μg/cm² for normal skin). These results offer reassurance as regards to the use of antiperspirants for topical application of ACH-containing cosmetic formulations on healthy skin over a limited time span (24h). On the other hand, high transdermal Al uptake on stripped skin should compel antiperspirant manufacturers to proceed with the utmost caution.

  15. Simple spectrophotometry method for the determination of sulfur dioxide in an alcohol-thionyl chloride reaction.

    PubMed

    Zheng, Jinjian; Tan, Feng; Hartman, Robert

    2015-09-01

    Thionyl chloride is often used to convert alcohols into more reactive alkyl chloride, which can be easily converted to many compounds that are not possible from alcohols directly. One important reaction of alkyl chloride is nucleophilic substitution, which is typically conducted under basic conditions. Sulfur dioxide, the by-product from alcohol-thionyl chloride reactions, often reacts with alkyl chloride to form a sulfonyl acid impurity, resulting in yield loss. Therefore, the alkyl chloride is typically isolated to remove the by-products including sulfur dioxide. However, in our laboratory, the alkyl chloride formed from alcohol and thionyl chloride was found to be a potential mutagenic impurity, and isolation of this compound would require extensive safety measures. As a result, a flow-through process was developed, and the sulfur dioxide was purged using a combination of vacuum degassing and nitrogen gas sweeping. An analytical method that can quickly and accurately quantitate residual levels of sulfur dioxide in the reaction mixture is desired for in-process monitoring. We report here a simple ultraviolet (UV) spectrophotometry method for this measurement. This method takes advantage of the dramatic change in the UV absorbance of sulfur dioxide with respect to pH, which allows for accurate quantitation of sulfur dioxide in the presence of the strong UV-absorbing matrix. Each sample solution was prepared using 2 different diluents: 1) 50 mM ammonium acetate in methanol +1% v/v hydrochloric acid, pH 1.3, and 2) 50 mM ammonium acetate in methanol +1% glacial acetic acid, pH 4.0. The buffer solutions were carefully selected so that the UV absorbance of the sample matrix (excluding sulfur dioxide) at 276 nm remains constant. In the pH 1.3 buffer system, sulfur dioxide shows strong UV absorbance at 276 nm. Therefore, the UV absorbance of sample solution is the sum of sulfur dioxide and sample matrix. While in the pH 4.0 buffer system, sulfur dioxide has

  16. The Ozone Show.

    ERIC Educational Resources Information Center

    Mathieu, Aaron

    2000-01-01

    Uses a talk show activity for a final assessment tool for students to debate about the ozone hole. Students are assessed on five areas: (1) cooperative learning; (2) the written component; (3) content; (4) self-evaluation; and (5) peer evaluation. (SAH)

  17. Show What You Know

    ERIC Educational Resources Information Center

    Eccleston, Jeff

    2007-01-01

    Big things come in small packages. This saying came to the mind of the author after he created a simple math review activity for his fourth grade students. Though simple, it has proven to be extremely advantageous in reinforcing math concepts. He uses this activity, which he calls "Show What You Know," often. This activity provides the perfect…

  18. Showing What They Know

    ERIC Educational Resources Information Center

    Cech, Scott J.

    2008-01-01

    Having students show their skills in three dimensions, known as performance-based assessment, dates back at least to Socrates. Individual schools such as Barrington High School--located just outside of Providence--have been requiring students to actively demonstrate their knowledge for years. The Rhode Island's high school graduating class became…

  19. Stage a Water Show

    ERIC Educational Resources Information Center

    Frasier, Debra

    2008-01-01

    In the author's book titled "The Incredible Water Show," the characters from "Miss Alaineus: A Vocabulary Disaster" used an ocean of information to stage an inventive performance about the water cycle. In this article, the author relates how she turned the story into hands-on science teaching for real-life fifth-grade students. The author also…

  20. What Do Maps Show?

    ERIC Educational Resources Information Center

    Geological Survey (Dept. of Interior), Reston, VA.

    This curriculum packet, appropriate for grades 4-8, features a teaching poster which shows different types of maps (different views of Salt Lake City, Utah), as well as three reproducible maps and reproducible activity sheets which complement the maps. The poster provides teacher background, including step-by-step lesson plans for four geography…

  1. Obesity in show cats.

    PubMed

    Corbee, R J

    2014-12-01

    Obesity is an important disease with a high prevalence in cats. Because obesity is related to several other diseases, it is important to identify the population at risk. Several risk factors for obesity have been described in the literature. A higher incidence of obesity in certain cat breeds has been suggested. The aim of this study was to determine whether obesity occurs more often in certain breeds. The second aim was to relate the increased prevalence of obesity in certain breeds to the official standards of that breed. To this end, 268 cats of 22 different breeds investigated by determining their body condition score (BCS) on a nine-point scale by inspection and palpation, at two different cat shows. Overall, 45.5% of the show cats had a BCS > 5, and 4.5% of the show cats had a BCS > 7. There were significant differences between breeds, which could be related to the breed standards. Most overweight and obese cats were in the neutered group. It warrants firm discussions with breeders and cat show judges to come to different interpretations of the standards in order to prevent overweight conditions in certain breeds from being the standard of beauty. Neutering predisposes for obesity and requires early nutritional intervention to prevent obese conditions. PMID:24612018

  2. Show Me the Way

    ERIC Educational Resources Information Center

    Dicks, Matthew J.

    2005-01-01

    Because today's students have grown up steeped in video games and the Internet, most of them expect feedback, and usually gratification, very soon after they expend effort on a task. Teachers can get quick feedback to students by showing them videotapes of their learning performances. The author, a 3rd grade teacher describes how the seemingly…

  3. The Art Show

    ERIC Educational Resources Information Center

    Scolarici, Alicia

    2004-01-01

    This article describes what once was thought to be impossible--a formal art show extravaganza at an elementary school with 1,000 students, a Department of Defense Dependent School (DODDS) located overseas, on RAF Lakenheath, England. The dream of this this event involved the transformation of the school cafeteria into an elegant art show…

  4. Honored Teacher Shows Commitment.

    ERIC Educational Resources Information Center

    Ratte, Kathy

    1987-01-01

    Part of the acceptance speech of the 1985 National Council for the Social Studies Teacher of the Year, this article describes the censorship experience of this honored social studies teacher. The incident involved the showing of a videotape version of the feature film entitled "The Seduction of Joe Tynan." (JDH)

  5. Absorption bands in the spectrum of Io

    NASA Technical Reports Server (NTRS)

    Cruikshank, D. P.; Jones, T. J.; Pilcher, C. B.

    1978-01-01

    Near-infrared spectra of Io in the region from 2.8 to 4.2 microns are reported which show distinct absorption features, the most notable at 4.1 microns. Frozen volatiles or atmospheric gases cannot account for these absorptions, nor do they resemble those seen in common silicate rocks. Several candidate substances, most notably nitrate and carbonate salts, show absorption features in this spectral region; the deepest band in the spectrum may be a nitrate absorption. The satellite surface is shown to be anhydrous, as indicated by the absence of the 3-micron bound water band.

  6. UV Spectrophotometry of the Hottest Stars from the Southern HK Survey

    NASA Astrophysics Data System (ADS)

    Drilling, John S.; Beers, Timothy C.

    1995-06-01

    Low-resolution UV spectra have been obtained with the long- and short-wavelength lUE cameras for seven of the hottest stars identified in the ongoing HK objective-prism/interference-filter survey begun by Beers, Preston, & Shectman. These stars are a subset of a sample of some 25,000 stars at high galactic latitude whose objective-prism spectra indicate that they are hotter than the Population II main-sequence turnoff in the magnitude range 11 ≤ B ≤ 15.5. The UV fluxes have been corrected for interstellar reddening using a standard reddening law, and comparison of the integrated fluxes in the two lUE cameras indicates that the effective temperatures of these stars range from 40,000 K to 80,000 K. The UV absorption spectra of six of the seven stars are characterized by a strong He II λ1640 line and 3-n series of He II. Five of these stars show strong C IV λ1550 absorption. The low-resolution UV spectrum of the remaining object is featureless.

  7. Taking in a Show.

    PubMed

    Boden, Timothy W

    2016-01-01

    Many medical practices have cut back on education and staff development expenses, especially those costs associated with conventions and conferences. But there are hard-to-value returns on your investment in these live events--beyond the obvious benefits of acquired knowledge and skills. Major vendors still exhibit their services and wares at many events, and the exhibit hall is a treasure-house of information and resources for the savvy physician or administrator. Make and stick to a purposeful plan to exploit the trade show. You can compare products, gain new insights and ideas, and even negotiate better deals with representatives anxious to realize returns on their exhibition investments. PMID:27249887

  8. Taking in a Show.

    PubMed

    Boden, Timothy W

    2016-01-01

    Many medical practices have cut back on education and staff development expenses, especially those costs associated with conventions and conferences. But there are hard-to-value returns on your investment in these live events--beyond the obvious benefits of acquired knowledge and skills. Major vendors still exhibit their services and wares at many events, and the exhibit hall is a treasure-house of information and resources for the savvy physician or administrator. Make and stick to a purposeful plan to exploit the trade show. You can compare products, gain new insights and ideas, and even negotiate better deals with representatives anxious to realize returns on their exhibition investments.

  9. Obesity in show dogs.

    PubMed

    Corbee, R J

    2013-10-01

    Obesity is an important disease with a growing incidence. Because obesity is related to several other diseases, and decreases life span, it is important to identify the population at risk. Several risk factors for obesity have been described in the literature. A higher incidence of obesity in certain breeds is often suggested. The aim of this study was to determine whether obesity occurs more often in certain breeds. The second aim was to relate the increased prevalence of obesity in certain breeds to the official standards of that breed. To this end, we investigated 1379 dogs of 128 different breeds by determining their body condition score (BCS). Overall, 18.6% of the show dogs had a BCS >5, and 1.1% of the show dogs had a BCS>7. There were significant differences between breeds, which could be correlated to the breed standards. It warrants firm discussions with breeders and judges in order to come to different interpretations of the standards to prevent overweight conditions from being the standard of beauty. PMID:22882163

  10. Speciation of selenium in environmental samples by solid-phase spectrophotometry using 2,3-dichloro-6-(2,7-dihydroxy-naphthylazo)quinoxaline.

    PubMed

    Amin, Alaa S

    2014-01-01

    Solid-phase spectrophotometry was applied to determination of trace amounts of selenium (Se) in water, soil, plant materials, human hair, and a cosmetic preparation (lipstick). Se(IV) was sorbed in a dextran type lipophilic gel as a complex with 2,3-dichloro-6-(2,7-dihydroxy-naphthylazo)quinoxaline (DCDHNAQ), whereas Se(VI) was determined after boiling in HCI for 10 min to convert Se(VI) to Se(IV). Resin phase absorbances at 588 and 800 nm were measured directly, which allowed the determination of Se in the range of 0.2-3.3 microg/L with an RSD of 1.22%. The influences of analytical parameters including pH of the aqueous solution, amounts of DCDHNAQ, and sample volume were investigated. The molar absorptivities were found to be 1.09 x 10(6), 4.60 x 10(6), and 1.23 x 10(7) L/mol cm for 100, 500, and 1000 mL, respectively. The LOD and LOQ of the 500 mL sample method were 110 and 360 ng/L, respectively, when using 50 mg dextran type lipophilic gel. For a 1000 mL sample, the LOD and LOQ were 60 and 200 ng/L, respectively, using 50 mg of the exchanger. Increasing the sample volume enhanced the sensitivity. No considerable interferences were observed from other investigated anions and cations on the Se determination. PMID:24830171

  11. Simple and fast method for iron determination in white and red wines using dispersive liquid-liquid microextraction and ultraviolet-visible spectrophotometry.

    PubMed

    Maciel, Juliana V; Soares, Bruno M; Mandlate, Jaime S; Picoloto, Rochele S; Bizzi, Cezar A; Flores, Erico M M; Duarte, Fabio A

    2014-08-20

    This work reports the development of a method for Fe extraction in white and red wines using dispersive liquid-liquid microextraction (DLLME) and determination by ultraviolet-visible spectrophotometry. For optimization of the DLLME method, the following parameters were evaluated: type and volume of dispersive (1300 μL of acetonitrile) and extraction (80 μL of C(2)Cl(4)) solvents, pH (3.0), concentration of ammonium pyrrolidinedithiocarbamate (APDC, 500 μL of 1% m/v APDC solution), NaCl concentration (not added), and extraction time. The calibration curve was performed using the analyte addition method, and the limit of detection and relative standard deviation were 0.2 mg L(-1) and below 7%, respectively. The accuracy was evaluated by comparison of results obtained after Fe determination by graphite furnace atomic absorption spectrometry, with agreement ranging from 94 to 105%. The proposed method was applied for Fe determination in white and red wines with concentrations ranging from 1.3 to 4.7 mg L(-1).

  12. Speciation of selenium in environmental samples by solid-phase spectrophotometry using 2,3-dichloro-6-(2,7-dihydroxy-naphthylazo)quinoxaline.

    PubMed

    Amin, Alaa S

    2014-01-01

    Solid-phase spectrophotometry was applied to determination of trace amounts of selenium (Se) in water, soil, plant materials, human hair, and a cosmetic preparation (lipstick). Se(IV) was sorbed in a dextran type lipophilic gel as a complex with 2,3-dichloro-6-(2,7-dihydroxy-naphthylazo)quinoxaline (DCDHNAQ), whereas Se(VI) was determined after boiling in HCI for 10 min to convert Se(VI) to Se(IV). Resin phase absorbances at 588 and 800 nm were measured directly, which allowed the determination of Se in the range of 0.2-3.3 microg/L with an RSD of 1.22%. The influences of analytical parameters including pH of the aqueous solution, amounts of DCDHNAQ, and sample volume were investigated. The molar absorptivities were found to be 1.09 x 10(6), 4.60 x 10(6), and 1.23 x 10(7) L/mol cm for 100, 500, and 1000 mL, respectively. The LOD and LOQ of the 500 mL sample method were 110 and 360 ng/L, respectively, when using 50 mg dextran type lipophilic gel. For a 1000 mL sample, the LOD and LOQ were 60 and 200 ng/L, respectively, using 50 mg of the exchanger. Increasing the sample volume enhanced the sensitivity. No considerable interferences were observed from other investigated anions and cations on the Se determination.

  13. The HI absorption "Zoo"

    NASA Astrophysics Data System (ADS)

    Geréb, K.; Maccagni, F. M.; Morganti, R.; Oosterloo, T. A.

    2015-03-01

    We present an analysis of the H I 21 cm absorption in a sample of 101 flux-selected radio AGN (S1.4 GHz> 50 mJy) observed with the Westerbork Synthesis Radio Telescope (WSRT). We detect H I absorption in 32 objects (30% of the sample). In a previous paper, we performed a spectral stacking analysis on the radio sources, while here we characterize the absorption spectra of the individual detections using the recently presented busy function. The H I absorption spectra show a broad variety of widths, shapes, and kinematical properties. The full width half maximum (FWHM) of the busy function fits of the detected H I lines lies in the range 32 km s-1absorption (FW20) lies in the range 63 km s-1 200 km s-1). We study the kinematical and radio source properties of each group, with the goal of identifying different morphological structures of H I. Narrow lines mostly lie at the systemic velocity and are likely produced by regularly rotating H I disks or gas clouds. More H I disks can be present among galaxies with lines of intermediate widths; however, the H I in these sources is more unsettled. We study the asymmetry parameter and blueshift/redshift distribution of the lines as a function of their width. We find a trend for which narrow profiles are also symmetric, while broad lines are the most asymmetric. Among the broadest lines, more lines appear blueshifted than redshifted, similarly to what was found by previous studies. Interestingly, symmetric broad lines are absent from the sample. We argue that if a profile is broad, it is also asymmetric and shifted relative to the systemic velocity because it is tracing unsettled H I gas. In particular, besides three of the broadest (up to FW20 = 825 km s-1

  14. Not a "reality" show.

    PubMed

    Wrong, Terence; Baumgart, Erica

    2013-01-01

    The authors of the preceding articles raise legitimate questions about patient and staff rights and the unintended consequences of allowing ABC News to film inside teaching hospitals. We explain why we regard their fears as baseless and not supported by what we heard from individuals portrayed in the filming, our decade-long experience making medical documentaries, and the full un-aired context of the scenes shown in the broadcast. The authors don't and can't know what conversations we had, what documents we reviewed, and what protections we put in place in each televised scene. Finally, we hope to correct several misleading examples cited by the authors as well as their offhand mischaracterization of our program as a "reality" show. PMID:23631336

  15. Not a "reality" show.

    PubMed

    Wrong, Terence; Baumgart, Erica

    2013-01-01

    The authors of the preceding articles raise legitimate questions about patient and staff rights and the unintended consequences of allowing ABC News to film inside teaching hospitals. We explain why we regard their fears as baseless and not supported by what we heard from individuals portrayed in the filming, our decade-long experience making medical documentaries, and the full un-aired context of the scenes shown in the broadcast. The authors don't and can't know what conversations we had, what documents we reviewed, and what protections we put in place in each televised scene. Finally, we hope to correct several misleading examples cited by the authors as well as their offhand mischaracterization of our program as a "reality" show.

  16. Public medical shows.

    PubMed

    Walusinski, Olivier

    2014-01-01

    In the second half of the 19th century, Jean-Martin Charcot (1825-1893) became famous for the quality of his teaching and his innovative neurological discoveries, bringing many French and foreign students to Paris. A hunger for recognition, together with progressive and anticlerical ideals, led Charcot to invite writers, journalists, and politicians to his lessons, during which he presented the results of his work on hysteria. These events became public performances, for which physicians and patients were transformed into actors. Major newspapers ran accounts of these consultations, more like theatrical shows in some respects. The resultant enthusiasm prompted other physicians in Paris and throughout France to try and imitate them. We will compare the form and substance of Charcot's lessons with those given by Jules-Bernard Luys (1828-1897), Victor Dumontpallier (1826-1899), Ambroise-Auguste Liébault (1823-1904), Hippolyte Bernheim (1840-1919), Joseph Grasset (1849-1918), and Albert Pitres (1848-1928). We will also note their impact on contemporary cinema and theatre. PMID:25273491

  17. The evaluation of a novel method comparing quantitative light-induced fluorescence (QLF) with spectrophotometry to assess staining and bleaching of teeth.

    PubMed

    Adeyemi, A A; Jarad, F D; de Josselin de Jong, E; Pender, N; Higham, S M

    2010-02-01

    This study reports the development and evaluation of a novel method using quantitative light-induced fluorescence (QLF), which enables its use for quantifying and assessing whole tooth surface staining and tooth whitening. The method was compared with a spectrophotometer to assess reliability. Two experimental phases, intrinsic stain formation and tooth whitening, were conducted in vitro on 16 extracted bovine teeth. Intrinsic stains were developed via access through lingual surfaces and root canals of these teeth using tea solution (2 g/100 ml, Marks and Spencer Extra Strong Tea, Marks and Spencer, London, UK) for 6 days. Stains were removed using 33% hydrogen peroxide (VWR Prolab, Leicestershire, UK) in cycles over 150 min. Stain development/whitening was monitored with QLF (Inspektor Research systems, Amsterdam, Netherlands) and spectrophotometry (Easy shade, Vita Zahnfabrik, Bad Säckingen, Germany). Parameters Delta F for QLF and Delta E for the spectrophotometer were obtained. The progression of stain intensity and removal observed by the methods were tested for correlation using Pearson's correlation coefficient. Intra-examiner reliability for each method was tested. QLF showed a high correlation with spectrophotometry for detecting and monitoring intrinsic tooth stain progression (Pearson coefficient r was -0.987 with correlation significant p < 0.0001). For stain removal, the Pearson coefficient (r) between both methods was -0.906 with no significance p = 0.094. The use of an external reference material in combination with the inner patch QLF analysis technique had the ability to detect and measure whole tooth surface staining and its removal longitudinally. The reliability of the method shows a potential clinical application. PMID:19306025

  18. Determination of losartan potassium, quinapril hydrochloride and hydrochlorothiazide in pharmaceutical preparations using derivative spectrophotometry and chromatographic-densitometric method.

    PubMed

    Stolarczyk, Mariusz; Maślanka, Anna; Apola, Anna; Krzek, Jan

    2013-01-01

    Two methods, spectrophotometric and chromatographic-densitometric ones, were developed for determination of losartan potassium, quinapril hydrochloride and hydrochlorothiazide in pharmaceutical preparations. Spectrophotometric method involved derivative spectrophotometry and zero order spectrophotometry. The measurements were carried out at lambda = 224.0 nm for quinapril, lambda = 261.0 nm for hydrochlorothiazide and lambda = 270.0 nm for losartan when the derivative spectrophotometry was applied and lambda = 317.0 nm when zero order spectrophotometry was applied for the determination of hydrochlorothiazide. In chromatographic-densitometric studies high performance thin layer chromatography (HPTLC) plates were used as stationary phase and a mixture of solvents n-butanol : acetic acid : water (15 : 5 : 1, v/v/v) as mobile phase. Under the established conditions good resolution of examined constituents was obtained. Retardation factor for quinapril hydrochloride was R(f) - 0.70, for losartan potassium R(f) - 0.85 and for hydrochlorothiazide R(f) - 0.78. The developed methods are characterized by high sensitivity and accuracy. For quantitative analysis, densitometric measurements were carried out at lambda = 218.0 nm for quinapril, lambda = 275.0 nm for hydrochlorothiazide and = 232.0 nm for losartan.

  19. Light absorption by phytoplankton, non-algal particles and dissolved organic matter at the Patagonia shelf-break in spring and summer

    NASA Astrophysics Data System (ADS)

    Ferreira, Amábile; Garcia, Virginia M. T.; Garcia, Carlos A. E.

    2009-12-01

    Satellite image studies and recent in situ sampling have identified conspicuous phytoplankton blooms during spring and summer along the Patagonia shelf-break front. The magnitudes and spectral characteristics of light absorption by total particulate matter (phytoplankton and detritus) and colored dissolved organic matter (CDOM) have been determined by spectrophotometry in that region for spring 2006 and late summer 2007 seasons. In spring, phytoplankton absorption was the dominant optical component of light absorption (60-85%), and CDOM showed variable and important contributions in summer (10-90%). However, there was a lack of correlation between phytoplankton biomass (chlorophyll- a concentration or [chl a]) and the non-algal compartment in both periods. A statistically significant difference was found between the two periods with respect to the CDOM spectral shape parameter ( Scdom), with means of 0.015 (spring) and 0.012 nm -1 (summer). Nonetheless, the mean Scdm values, which describe the slope of detritus plus CDOM spectra, did not differ between the periods (average of 0.013 nm -1). Phytoplankton absorption values in this work showed deviations from mean parameterizations in previous studies, with respect to [chl a], as well as between the two study periods. In spring, despite the microplankton dominance, high specific absorption values and large dispersion were found ( a* ph(440)=0.04±0.03 m 2 mg [chl a] -1), which could be attributed to an important influence of photo-protector accessory pigments. In summer, deviations from general trends, with values of a* ph(440) even higher (0.09±0.02 m 2 mg [chl a] -1), were due to the dominance of small cell sizes and also to accessory pigments. These results highlight the difficulty in deriving robust relationships between chlorophyll concentration and phytoplankton absorption coefficients regardless of the season period. The validity of a size parameter ( Sf) derived from the absorption spectra has been

  20. The Great Cometary Show

    NASA Astrophysics Data System (ADS)

    2007-01-01

    its high spatial and spectral resolution, it was possible to zoom into the very heart of this very massive star. In this innermost region, the observations are dominated by the extremely dense stellar wind that totally obscures the underlying central star. The AMBER observations show that this dense stellar wind is not spherically symmetric, but exhibits a clearly elongated structure. Overall, the AMBER observations confirm that the extremely high mass loss of Eta Carinae's massive central star is non-spherical and much stronger along the poles than in the equatorial plane. This is in agreement with theoretical models that predict such an enhanced polar mass-loss in the case of rapidly rotating stars. ESO PR Photo 06c/07 ESO PR Photo 06c/07 RS Ophiuchi in Outburst Several papers from this special feature focus on the later stages in a star's life. One looks at the binary system Gamma 2 Velorum, which contains the closest example of a star known as a Wolf-Rayet. A single AMBER observation allowed the astronomers to separate the spectra of the two components, offering new insights in the modeling of Wolf-Rayet stars, but made it also possible to measure the separation between the two stars. This led to a new determination of the distance of the system, showing that previous estimates were incorrect. The observations also revealed information on the region where the winds from the two stars collide. The famous binary system RS Ophiuchi, an example of a recurrent nova, was observed just 5 days after it was discovered to be in outburst on 12 February 2006, an event that has been expected for 21 years. AMBER was able to detect the extension of the expanding nova emission. These observations show a complex geometry and kinematics, far from the simple interpretation of a spherical fireball in extension. AMBER has detected a high velocity jet probably perpendicular to the orbital plane of the binary system, and allowed a precise and careful study of the wind and the shockwave

  1. Catalog of far-ultraviolet objective-prism spectrophotometry: Skylab experiment S-019, ultraviolet steller astronomy

    NASA Technical Reports Server (NTRS)

    Henize, K. G.; Wray, J. D.; Parsons, S. B.; Benedict, G. F.

    1979-01-01

    Ultraviolet stellar spectra in the wavelength region from 1300 to 5000 A (130 to 500) were photographed during the three manned Skylab missions using a 15 cm aperture objective-prism telescope. The prismatic dispersion varied from 58 A mm/1 at 1400 A to 1600 A mm/1 at 3000 A. Approximately 1000 spectra representing 500 stars were measured and reduced to observed fluxes. About 100 stars show absorption lines of Si IV, C IV, or C II. Numerous line features are also recorded in supergiant stars, shell stars, A and F stars, and Wolf-Rayet stars. Most of the stars in the catalog are of spectral class B, with a number of O and A type stars and a sampling of WC, WN, F and C type stars. Spectrophotometric results are tabulated for these 500 stars.

  2. Developments of Si-PIN detectors for Continuous Spectro-photometry of Black Holes (CSPOB)

    SciTech Connect

    Bhoumik, Debashis; Mondal, Shyamal; Chakrabarti, S. K.

    2008-10-08

    The goal of the proposed small-satellite mission named Continuous Spectro-Photometry of Black holes (CSPOB) is to observe a given galactic black hole candidate for several months continuously or almost continuously. In the former case, two identical satellites are required, while one satellite is sufficient if we employ one satellite. Such an observation from 0.5keV to 30keV should answer several questions regarding the spectral and timing properties of accretion processes. In particular, on the origin of the sub-Keplerian component of the accretion flow which is observed in many black hole candidates. We present preliminary results on the development of X-ray detectors based on Hamamatsu made Si-PIN Photodiodes at our laboratory.

  3. Spatially Multiplexed Micro-Spectrophotometry in Bright Field Mode for Thin Film Characterization

    PubMed Central

    Pini, Valerio; Kosaka, Priscila M.; Ruz, Jose J.; Malvar, Oscar; Encinar, Mario; Tamayo, Javier; Calleja, Montserrat

    2016-01-01

    Thickness characterization of thin films is of primary importance in a variety of nanotechnology applications, either in the semiconductor industry, quality control in nanofabrication processes or engineering of nanoelectromechanical systems (NEMS) because small thickness variability can strongly compromise the device performance. Here, we present an alternative optical method in bright field mode called Spatially Multiplexed Micro-Spectrophotometry that allows rapid and non-destructive characterization of thin films over areas of mm2 and with 1 μm of lateral resolution. We demonstrate an accuracy of 0.1% in the thickness characterization through measurements performed on four microcantilevers that expand an area of 1.8 mm2 in one minute of analysis time. The measured thickness variation in the range of few tens of nm translates into a mechanical variability that produces an error of up to 2% in the response of the studied devices when they are used to measure surface stress variations. PMID:27338398

  4. Do GSM 900MHz signals affect cerebral blood circulation? A near-infrared spectrophotometry study

    NASA Astrophysics Data System (ADS)

    Wolf, Martin; Haensse, Daniel; Morren, Geert; Froehlich, Juerg

    2006-06-01

    Effects of GSM 900MHz signals (EMF) typical for a handheld mobile phone on the cerebral blood circulation were investigated using near-infrared spectrophotometry (NIRS) in a three armed (12W/kg, 1.2W/kg, sham), double blind, randomized crossover trial in 16 healthy volunteers. During exposure we observed borderline significant short term responses of oxyhemoglobin and deoxyhemoglobin concentration, which correspond to a decrease of cerebral blood flow and volume and were smaller than regular physiological changes. Due to the relatively high number of statistical tests, these responses may be spurious and require further studies. There was no detectable dose-response relation or long term response within 20min. The detection limit was a fraction of the regular physiological changes elicited by functional activation. Compared to previous studies using PET, NIRS provides a much higher time resolution, which allowed investigating the short term effects efficiently, noninvasively, without the use of radioactive tracers and with high sensitivity.

  5. Determination of the degree of acetylation of chitosan by UV spectrophotometry using dual standards.

    PubMed

    Liu, Dasheng; Wei, Yuanan; Yao, Pingjia; Jiang, Linbin

    2006-05-01

    Determination of the degree of acetylation of chitosan by UV spectrophotometry using dual standards is investigated. The UV absorbance of a pure chitosan solution is contributed additively by the N-acetylglucosamine and glucosamine residues; the absorbance divided by the total molar concentration of the residues (A/c(t)) is linearly related to the degree of acetylation (DA). Using acetyl glucosamine and glucosamine hydrochloride as standards in 0.1M hydrochloric acid solution, the equation obtained by linear regression is A/c(t)=3.3615 DA+0.0218, R(2)=0.9958. The DA of the analytical sample (m milligram of chitosan in V liters solution) can be calculated by.

  6. Spatially Multiplexed Micro-Spectrophotometry in Bright Field Mode for Thin Film Characterization.

    PubMed

    Pini, Valerio; Kosaka, Priscila M; Ruz, Jose J; Malvar, Oscar; Encinar, Mario; Tamayo, Javier; Calleja, Montserrat

    2016-01-01

    Thickness characterization of thin films is of primary importance in a variety of nanotechnology applications, either in the semiconductor industry, quality control in nanofabrication processes or engineering of nanoelectromechanical systems (NEMS) because small thickness variability can strongly compromise the device performance. Here, we present an alternative optical method in bright field mode called Spatially Multiplexed Micro-Spectrophotometry that allows rapid and non-destructive characterization of thin films over areas of mm² and with 1 μm of lateral resolution. We demonstrate an accuracy of 0.1% in the thickness characterization through measurements performed on four microcantilevers that expand an area of 1.8 mm² in one minute of analysis time. The measured thickness variation in the range of few tens of nm translates into a mechanical variability that produces an error of up to 2% in the response of the studied devices when they are used to measure surface stress variations.

  7. Far-ultraviolet and optical spectrophotometry of X-ray selected Seyfert galaxies

    NASA Technical Reports Server (NTRS)

    Clarke, J. T.; Bowyer, S.; Grewing, M.

    1986-01-01

    Five X-ray selected Seyfert galaxies were examined via near-simultaneous far-ultraviolet and optical spectrophotometry in an effort to test models for excitation of emission lines by X-ray and ultraviolet continuum photoionization. The observed Ly-alpha/H-beta ratio in the present sample averages 22, with an increase found toward the high-velocity wings of the H lines in the spectrum of at least one of the Seyfert I nuclei. It is suggested that Seyfert galaxies with the most high-velocity gas exhibit the highest Ly-alpha/H-beta ratios at all velocities in the line profiles, and that sometimes this ratio may be highest for the highest velocity material in the broad-line clouds. Since broad-lined objects are least affected by Ly-alpha trapping effects, they have Ly-alpha/H-beta ratios much closer to those predicted by early photoionization calculations.

  8. Antioxidant study of quercetin and their metal complex and determination of stability constant by spectrophotometry method.

    PubMed

    Ravichandran, R; Rajendran, M; Devapiriam, D

    2014-03-01

    Quercetin found chelate cadmium ions, scavenge free radicals produced by cadmium. Hence new complex, quercetin with cadmium was synthesised, and the synthesised complex structures were determined by UV-vis spectrophotometry, infrared spectroscopy, thermogravimetry and differential thermal analysis techniques (UV-vis, IR, TGA and DTA). The equilibrium stability constants of quercetin-cadmium complex were determined by Job's method. The determined stability constant value of quercetin-cadminum complex at pH 4.4 is 2.27×10(6) and at pH 7.4 is 7.80×10(6). It was found that the quercetin and cadmium ion form 1:1 complex in both pH 4.4 and pH 7.4. The structure of the compounds was elucidated on the basis of obtained results. Furthermore, the antioxidant activity of the free quercetin and quercetin-cadmium complexes were determined by DPPH and ABTS assays.

  9. Heterodyne spectrophotometry of ozone in the 9.6-micron band using a tunable diode laser

    NASA Technical Reports Server (NTRS)

    Mcelroy, C. T.; Goldman, A.; Fogal, P. F.; Murcray, D. G.

    1990-01-01

    Tunable diode laser heterodyne spectrophotometry (TDLHS) has been used to make extremely high resolution (0.0003/cm) solar spectra in the 9.6-micron ozone band. Observations have shown that a signal-to-noise ratio of 120:1 (about 30 percent of theoretical) for an integration time of 1/8 s can be achieved at a resolution of 0.0013 wave numbers. The spectral data have been inverted to yield a total column amount of ozone, in good agreement with that measured at the nearby NOAA ozone monitoring facility in Boulder, Colorado. Line positions for several ozone lines in the spectral region 996-997/cm are reported. Recent improvements have produced a signal-to-noise ratio of 95:1 (about 40 percent of theoretical) at 0.0003/cm and extended the range of wavelengths which can be observed.

  10. Spectrophotometry of Wolf-Rayet stars - Intrinsic colors and absolute magnitudes

    NASA Technical Reports Server (NTRS)

    Torres-Dodgen, Ana V.; Massey, Philip

    1988-01-01

    Absolute spectrophotometry of about 10-A resolution in the range 3400-7300 A have been obtained for southern Wolf-Rayet stars, and line-free magnitudes and colors have been constructed. The emission-line contamination in the narrow-band ubvr systems of Westerlund (1966) and Smith (1968) is shown to be small for most WN stars, but to be quite significant for WC stars. It is suggested that the more severe differences in intrinsic color from star to star of the same spectral subtype noted at shorter wavelengths are due to differences in atmospheric extent. True continuum absolute visual magnitudes and intrinsic colors are obtained for the LMC WR stars. The most visually luminous WN6-WN7 stars are found to be located in the core of the 30 Doradus region.

  11. Airborne and groundbased spectrophotometry of comet P/Halley from 5-13 micrometers

    NASA Technical Reports Server (NTRS)

    Bregman, J. D.; Witteborn, F. C.; Allamandola, L. J.; Campins, H.; Wooden, D. H.; Rank, D. M.; Cohen, M.; Tielens, A. G. G. M.

    1987-01-01

    Spectrophotometry of comet Halley from 5-13 microns was obtained from the Kuiper Airborne Observatory and from the Lick Observatory Nickel Telescope, revealing a strong broad emission band at 10 microns and a weak feature at 6.8 microns. The 10-micron band is identified with silicate materials, and the primary component of the silicate emission is suggested to be due to olivine. The 6.8 micron feature may be due either to carbonates or the C-H deformation mode in organic molecules. The data indicate that small particles are abundant in the coma and that the dust contains at least two physically separate components. Significant spatial and temporal variations are also noted in the spectrum.

  12. Ultraviolet spectrophotometry of comet Giacobini-Zinner during the ICE encounter. [International Cometary Explorer (ICE)

    NASA Technical Reports Server (NTRS)

    Ahearn, Michael F.; Mcfadden, Lucy A.; Feldman, Paul D.; Boehnhardt, Hermann; Rahe, Juergen; Festou, Michael; Brandt, John C.; Maran, Stephen P.; Niedner, Malcom B.; Smith, Andrew M.

    1986-01-01

    The IUE spectrophotometry of Comet P/Giacobini-Zinner was acquired in support of the International Cometary Explorer (ICE) mission. The abundances (or upper limits) of UV-active species were calculated. During the ICE encounter the H2O production rate was 3 times 10 to the 28th power/sec, + or - 50%, consistent with values derived from the ICE experiments. Comparison of the abundance of CO2(+) ions with the total electron density measured by the plasma electron experiment on ICE indicates a deficiency of ions relative to electrons indicating a population of ions not detected by remote sensing. The absence of detectable Mg(+) rules out this species as a possible ion of M/Q = 24 detected by the Ion Composition Instrument, part of the ICE complement of instruments.

  13. Spatially Multiplexed Micro-Spectrophotometry in Bright Field Mode for Thin Film Characterization.

    PubMed

    Pini, Valerio; Kosaka, Priscila M; Ruz, Jose J; Malvar, Oscar; Encinar, Mario; Tamayo, Javier; Calleja, Montserrat

    2016-01-01

    Thickness characterization of thin films is of primary importance in a variety of nanotechnology applications, either in the semiconductor industry, quality control in nanofabrication processes or engineering of nanoelectromechanical systems (NEMS) because small thickness variability can strongly compromise the device performance. Here, we present an alternative optical method in bright field mode called Spatially Multiplexed Micro-Spectrophotometry that allows rapid and non-destructive characterization of thin films over areas of mm² and with 1 μm of lateral resolution. We demonstrate an accuracy of 0.1% in the thickness characterization through measurements performed on four microcantilevers that expand an area of 1.8 mm² in one minute of analysis time. The measured thickness variation in the range of few tens of nm translates into a mechanical variability that produces an error of up to 2% in the response of the studied devices when they are used to measure surface stress variations. PMID:27338398

  14. Stretched View Showing 'Victoria'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    [figure removed for brevity, see original site] Stretched View Showing 'Victoria'

    This pair of images from the panoramic camera on NASA's Mars Exploration Rover Opportunity served as initial confirmation that the two-year-old rover is within sight of 'Victoria Crater,' which it has been approaching for more than a year. Engineers on the rover team were unsure whether Opportunity would make it as far as Victoria, but scientists hoped for the chance to study such a large crater with their roving geologist. Victoria Crater is 800 meters (nearly half a mile) in diameter, about six times wider than 'Endurance Crater,' where Opportunity spent several months in 2004 examining rock layers affected by ancient water.

    When scientists using orbital data calculated that they should be able to detect Victoria's rim in rover images, they scrutinized frames taken in the direction of the crater by the panoramic camera. To positively characterize the subtle horizon profile of the crater and some of the features leading up to it, researchers created a vertically-stretched image (top) from a mosaic of regular frames from the panoramic camera (bottom), taken on Opportunity's 804th Martian day (April 29, 2006).

    The stretched image makes mild nearby dunes look like more threatening peaks, but that is only a result of the exaggerated vertical dimension. This vertical stretch technique was first applied to Viking Lander 2 panoramas by Philip Stooke, of the University of Western Ontario, Canada, to help locate the lander with respect to orbiter images. Vertically stretching the image allows features to be more readily identified by the Mars Exploration Rover science team.

    The bright white dot near the horizon to the right of center (barely visible without labeling or zoom-in) is thought to be a light-toned outcrop on the far wall of the crater, suggesting that the rover can see over the low rim of Victoria. In figure 1, the northeast and southeast rims are labeled

  15. Levels of cadmium, lead and zinc protoporphyrin absorption in different risk groups.

    PubMed

    Aurelio, L M; Pilar, D L; Fulgencio, G G; Adoración, P B; Enrique, G C; Alicia, H M; Aurelio, L M

    1993-12-01

    We studied groups of workers, of pregnant women and of neonates exposed and unexposed to cadmium and lead at their place of work or in the environment. A total of 118 exposed and 28 unexposed workers were studied, together with 90 exposed and 100 unexposed pregnant women and neonates. Concentrations of cadmium and lead in the blood were determined by atomic absorption spectrophotometry. There were significant differences in cadmium concentrations between workers and neonates, and significant differences in lead concentrations between workers and pregnant women. We believe these differences are due mainly to high levels of pollution in the area studied.

  16. Optical Absorption, Stability and Structure of NpO2+ Complexeswith Dicarboxylic Acids

    SciTech Connect

    Guoxin Tian; Linfeng Rao

    2006-01-04

    Complexation of NpO2+ with oxalic acid (OX),2,2'-oxydiacetic acid (ODA), 2,2'-iminodiacetic acid (IDA) and 2,2'-thiodiacetic acid (TDA), has been studied using spectrophotometry in1 M NaClO4. Both the position and the intensity of the absorption band of NpO2+ at 980 nm are affected by the formation of NpO2+/dicarboxylate complexes, providing useful information on the complexation strength, the coordination mode and the structure of the complexes.

  17. Solid methane on Triton and Pluto - 3- to 4-micron spectrophotometry

    NASA Technical Reports Server (NTRS)

    Spencer, John R.; Buie, Marc W.; Bjoraker, Gordon L.

    1990-01-01

    Methane has been identified in the Pluto/Charon system on the basis of absorption features in the reflectance spectrum at 1.5 and 2.3 microns; attention is presently given to observations of a 3.25 micron-centered deep absorption feature in Triton and Pluto/Charon system reflectance spectra. This absorption may indicate the presence of solid methane, constituting either the dominant surface species or a mixture with a highly transparent substance, such as N2 frost.

  18. Effect of charge and lipid concentration on in-vivo percutaneous absorption of methyl nicotinate from liposomal vesicles.

    PubMed

    Puglia, Carmelo; Esposito, Elisabetta; Menegatti, Enea; Nastruzzi, Claudio; Rizza, Luisa; Cortesi, Rita; Bonina, Francesco

    2005-09-01

    We have investigated the influence of charge and lipid concentration on the in-vivo percutaneous absorption of a model compound, methyl nicotinate (MN), from liposomal vesicles. MN-loaded liposomes were produced by the reverse-phase evaporation method (REV) using different concentrations of phosphatidyl choline (PC), in association with surfactants such as dioctadecyl dimethyl ammonium bromide (DDAB18) and dicetyl phosphate (DCP), which impart a positive or negative charge to the systems, respectively. The liposomal suspensions were then processed to hydrogels and used to study in-vivo the MN permeation profile. MN was chosen as the model compound since it was capable of causing cutaneous erythema, the intensity and duration of which was proportional to the amount entering the living epidermis over time. The extent of the erythema was monitored by reflectance spectrophotometry, a non-invasive technique. In-vivo findings showed an interesting MN delayed release, which was proportional to the amount of phospholipids in each liposomal formulation. Furthermore, it could be noted that the erythematous effect was more prolonged when MN was delivered from neutral or negatively-charged liposomal forms.

  19. Solar absorption surface panel

    DOEpatents

    Santala, Teuvo J.

    1978-01-01

    A composite metal of aluminum and nickel is used to form an economical solar absorption surface for a collector plate wherein an intermetallic compound of the aluminum and nickel provides a surface morphology with high absorptance and relatively low infrared emittance along with good durability.

  20. Slow light and saturable absorption

    NASA Astrophysics Data System (ADS)

    Selden, A. C.

    2009-06-01

    Quantitative analysis of slow light experiments utilising coherent population oscillation (CPO) in a range of saturably absorbing media, including ruby and alexandrite, Er3+:Y2SiO5, bacteriorhodopsin, semiconductor quantum devices and erbium-doped optical fibres, shows that the observations may be more simply interpreted as saturable absorption phenomena. A basic two-level model of a saturable absorber displays all the effects normally associated with slow light, namely phase shift and modulation gain of the transmitted signal, hole burning in the modulation frequency spectrum and power broadening of the spectral hole, each arising from the finite response time of the non-linear absorption. Only where hole-burning in the optical spectrum is observed (using independent pump and probe beams), or pulse delays exceeding the limits set by saturable absorption are obtained, can reasonable confidence be placed in the observation of slow light in such experiments. Superluminal (“fast light”) phenomena in media with reverse saturable absorption (RSA) may be similarly explained.

  1. Quasar Absorption Studies

    NASA Technical Reports Server (NTRS)

    Mushotzky, Richard (Technical Monitor); Elvis, Martin

    2004-01-01

    The aim of the proposal is to investigate the absorption properties of a sample of inter-mediate redshift quasars. The main goals of the project are: Measure the redshift and the column density of the X-ray absorbers; test the correlation between absorption and redshift suggested by ROSAT and ASCA data; constrain the absorber ionization status and metallicity; constrain the absorber dust content and composition through the comparison between the amount of X-ray absorption and optical dust extinction. Unanticipated low energy cut-offs where discovered in ROSAT spectra of quasars and confirmed by ASCA, BeppoSAX and Chandra. In most cases it was not possible to constrain adequately the redshift of the absorber from the X-ray data alone. Two possibilities remain open: a) absorption at the quasar redshift; and b) intervening absorption. The evidences in favour of intrinsic absorption are all indirect. Sensitive XMM observations can discriminate between these different scenarios. If the absorption is at the quasar redshift we can study whether the quasar environment evolves with the Cosmic time.

  2. Solid methane on Triton and Pluto - 3- to 4-micron spectrophotometry

    SciTech Connect

    Spencer, J.R.; Buie, M.W.; Bjoraker, G.L. Space Telescope Science Institute, Baltimore, MD NASA, Goddard Space Flight Center, Greenbelt, MD )

    1990-12-01

    Methane has been identified in the Pluto/Charon system on the basis of absorption features in the reflectance spectrum at 1.5 and 2.3 microns; attention is presently given to observations of a 3.25 micron-centered deep absorption feature in Triton and Pluto/Charon system reflectance spectra. This absorption may indicate the presence of solid methane, constituting either the dominant surface species or a mixture with a highly transparent substance, such as N2 frost. 35 refs.

  3. Absorption of solar radiation by clouds: observations versus models.

    PubMed

    Cess, R D; Zhang, M H; Minnis, P; Corsetti, L; Dutton, E G; Forgan, B W; Garber, D P; Gates, W L; Hack, J J; Harrison, E F; Jing, X; Kiehi, J T; Long, C N; Morcrette, J J; Potter, G L; Ramanathan, V; Subasilar, B; Whitlock, C H; Young, D F; Zhou, Y

    1995-01-27

    There has been a long history of unexplained anomalous absorption of solar radiation by clouds. Collocated satellite and surface measurements of solar radiation at five geographically diverse locations showed significant solar absorption by clouds, resulting in about 25 watts per square meter more global-mean absorption by the cloudy atmosphere than predicted by theoretical models. It has often been suggested that tropospheric aerosols could increase cloud absorption. But these aerosols are temporally and spatially heterogeneous, whereas the observed cloud absorption is remarkably invariant with respect to season and location. Although its physical cause is unknown, enhanced cloud absorption substantially alters our understanding of the atmosphere's energy budget.

  4. Absorption of Solar Radiation by Clouds: Observations Versus Models

    NASA Technical Reports Server (NTRS)

    Cess, R. D.; Zhang, M. H.; Minnis, P.; Corsetti, L.; Dutton, E. G.; Forgan, B. W.; Garber, D. P.; Gates, W. L.; Hack, J. J.; Harrison, E. F.; Jing, X.; Kiehl, J. T.; Long, C. N.; Morcrette, J.-J.; Potter, G. L.; Ramanathan, V.; Subasilar, B.; Whitlock, C. H.; Young, D. F.; Zhou, Y.

    1995-01-01

    There has been a long history of unexplained anomalous absorption of solar radiation by clouds. Collocated satellite and surface measurements of solar radiation at five geographically diverse locations showed significant solar absorption by clouds, resulting in about 25 watts per square meter more global-mean absorption by the cloudy atmosphere than predicted by theoretical models. It has often been suggested that tropospheric aerosols could increase cloud absorption. But these aerosols are temporally and spatially heterogeneous, whereas the observed cloud absorption is remarkably invariant with respect to season and location. Although its physical cause is unknown, enhanced cloud absorption substantially alters our understanding of the atmosphere's energy budget.

  5. On the Ammonia Absorption on Saturn

    NASA Astrophysics Data System (ADS)

    Tejfel, Victor G.; Karimov, A. M.; Lyssenko, P. G.; Kharitonova, G. A.

    2015-11-01

    The ammonia absorption bands centered at wavelengths of 645 and 787 nm in the visible spectrum of Saturn are very weak and overlapped with more strong absorption bands of methane. Therefore, the allocation of these bands is extremely difficult. In fact, the NH3 band 787 nm is completely masked by methane. The NH3 645 nm absorption band is superimposed on a relatively weak shortwave wing of CH4 band, in which the absorption maximum lies at the wavelength of 667 nm. In 2009, during the equinox on Saturn we have obtained the series of zonal spectrograms by scanning of the planet disk from the southern to the northern polar limb. Besides studies of latitudinal variation of the methane absorption bands we have done an attempt to trace the behavior of the absorption of ammonia in the band 645 nm. Simple selection of the pure NH3 profile of the band was not very reliable. Therefore, after normalizing to the ring spectrum and to the level of the continuous spectrum for entire band ranging from 630 to 680 nm in the equivalent widths were calculated for shortwave part of this band (630-652 nm), where the ammonia absorption is present, and a portion of the band CH4 652-680 nm. In any method of eliminating the weak part of the methane uptake in the short wing show an increased ammonia absorption in the northern hemisphere compared to the south. This same feature is observed also in the behavior of weak absorption bands of methane in contrast to the more powerful, such as CH4 725 and 787 nm. This is due to the conditions of absorption bands formation in the clouds at multiple scattering. Weak absorption bands of methane and ammonia are formed on the large effective optical depths and their behavior reflects the differences in the degree of uniformity of the aerosol component of the atmosphere of Saturn.

  6. Absorption imaging of a single atom.

    PubMed

    Streed, Erik W; Jechow, Andreas; Norton, Benjamin G; Kielpinski, David

    2012-07-03

    Absorption imaging has played a key role in the advancement of science from van Leeuwenhoek's discovery of red blood cells to modern observations of dust clouds in stellar nebulas and Bose-Einstein condensates. Here we show the first absorption imaging of a single atom isolated in a vacuum. The optical properties of atoms are thoroughly understood, so a single atom is an ideal system for testing the limits of absorption imaging. A single atomic ion was confined in an RF Paul trap and the absorption imaged at near wavelength resolution with a phase Fresnel lens. The observed image contrast of 3.1 (3)% is the maximum theoretically allowed for the imaging resolution of our set-up. The absorption of photons by single atoms is of immediate interest for quantum information processing. Our results also point out new opportunities in imaging of light-sensitive samples both in the optical and X-ray regimes.

  7. Novel absorption detection techniques for capillary electrophoresis

    SciTech Connect

    Xue, Y.

    1994-07-27

    Capillary electrophoresis (CE) has emerged as one of the most versatile separation methods. However, efficient separation is not sufficient unless coupled to adequate detection. The narrow inner diameter (I.D.) of the capillary column raises a big challenge to detection methods. For UV-vis absorption detection, the concentration sensitivity is only at the {mu}M level. Most commercial CE instruments are equipped with incoherent UV-vis lamps. Low-brightness, instability and inefficient coupling of the light source with the capillary limit the further improvement of UV-vis absorption detection in CE. The goals of this research have been to show the utility of laser-based absorption detection. The approaches involve: on-column double-beam laser absorption detection and its application to the detection of small ions and proteins, and absorption detection with the bubble-shaped flow cell.

  8. Creating semiconductor metafilms with designer absorption spectra.

    PubMed

    Kim, Soo Jin; Fan, Pengyu; Kang, Ju-Hyung; Brongersma, Mark L

    2015-01-01

    The optical properties of semiconductors are typically considered intrinsic and fixed. Here we leverage the rapid developments in the field of optical metamaterials to create ultrathin semiconductor metafilms with designer absorption spectra. We show how such metafilms can be constructed by placing one or more types of high-index semiconductor antennas into a dense array with subwavelength spacings. It is argued that the large absorption cross-section of semiconductor antennas and their weak near-field coupling open a unique opportunity to create strongly absorbing metafilms whose spectral absorption properties directly reflect those of the individual antennas. Using experiments and simulations, we demonstrate that near-unity absorption at one or more target wavelengths of interest can be achieved in a sub-50-nm-thick metafilm using judiciously sized and spaced Ge nanobeams. The ability to create semiconductor metafilms with custom absorption spectra opens up new design strategies for planar optoelectronic devices and solar cells. PMID:26184335

  9. Creating semiconductor metafilms with designer absorption spectra

    PubMed Central

    Kim, Soo Jin; Fan, Pengyu; Kang, Ju-Hyung; Brongersma, Mark L.

    2015-01-01

    The optical properties of semiconductors are typically considered intrinsic and fixed. Here we leverage the rapid developments in the field of optical metamaterials to create ultrathin semiconductor metafilms with designer absorption spectra. We show how such metafilms can be constructed by placing one or more types of high-index semiconductor antennas into a dense array with subwavelength spacings. It is argued that the large absorption cross-section of semiconductor antennas and their weak near-field coupling open a unique opportunity to create strongly absorbing metafilms whose spectral absorption properties directly reflect those of the individual antennas. Using experiments and simulations, we demonstrate that near-unity absorption at one or more target wavelengths of interest can be achieved in a sub-50-nm-thick metafilm using judiciously sized and spaced Ge nanobeams. The ability to create semiconductor metafilms with custom absorption spectra opens up new design strategies for planar optoelectronic devices and solar cells. PMID:26184335

  10. Broadband microwave absorption spectrometer for liquid media

    SciTech Connect

    Mukherjee, P.; Gosnell, T.R.; Bigio, I.J.

    1988-12-01

    A broadband, continuous-sweep microwave spectrometer has been constructed for measurements of the absorption coefficient of aqueous solutions and other liquid media. The spectrometer makes use of the phase fluctuation optical heterodyne technique, which provides a direct measure of the microwave power deposited in the sample. Consequently, in contrast to the standard dielectrometric techniques that indirectly determine the absorption coefficient via separate measurements of the real and imaginary parts of the dielectric constant, this spectrometer directly measures the microwave absorption coefficient. Broadband spectra are obtained using a transmission line to couple microwave power into the liquid sample. The absorption spectrum for deionized water in the range 3--20 GHz is presented as an example and shows excellent agreement with calculated values of the absorption coefficient based on previously published dielectric data.

  11. Creating semiconductor metafilms with designer absorption spectra

    NASA Astrophysics Data System (ADS)

    Kim, Soo Jin; Fan, Pengyu; Kang, Ju-Hyung; Brongersma, Mark L.

    2015-07-01

    The optical properties of semiconductors are typically considered intrinsic and fixed. Here we leverage the rapid developments in the field of optical metamaterials to create ultrathin semiconductor metafilms with designer absorption spectra. We show how such metafilms can be constructed by placing one or more types of high-index semiconductor antennas into a dense array with subwavelength spacings. It is argued that the large absorption cross-section of semiconductor antennas and their weak near-field coupling open a unique opportunity to create strongly absorbing metafilms whose spectral absorption properties directly reflect those of the individual antennas. Using experiments and simulations, we demonstrate that near-unity absorption at one or more target wavelengths of interest can be achieved in a sub-50-nm-thick metafilm using judiciously sized and spaced Ge nanobeams. The ability to create semiconductor metafilms with custom absorption spectra opens up new design strategies for planar optoelectronic devices and solar cells.

  12. Absorption heat pump system

    DOEpatents

    Grossman, G.

    1982-06-16

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  13. Absorption heat pump system

    DOEpatents

    Grossman, Gershon

    1984-01-01

    The efficiency of an absorption heat pump system is improved by conducting liquid from a second stage evaporator thereof to an auxiliary heat exchanger positioned downstream of a primary heat exchanger in the desorber of the system.

  14. Compounds affecting cholesterol absorption

    NASA Technical Reports Server (NTRS)

    Hua, Duy H. (Inventor); Koo, Sung I. (Inventor); Noh, Sang K. (Inventor)

    2004-01-01

    A class of novel compounds is described for use in affecting lymphatic absorption of cholesterol. Compounds of particular interest are defined by Formula I: ##STR1## or a pharmaceutically acceptable salt thereof.

  15. Direct UV Spectrophotometry and HPLC Determination of Triton X-100 in Split Virus Influenza Vaccine.

    PubMed

    Pavlović, Bojana; Cvijetić, Nataša; Dragačević, Luka; Ivković, Branka; Vujić, Zorica; Kuntić, Vesna

    2016-01-01

    One of the most commonly used surfactants in the production of split virus influenza vaccine is nonionic surfactant Triton X-100. After splitting of the virus is accomplished, Triton X-100 is removed from the vaccine by subsequent production steps. Because of toxicity of Triton X-100, which remains in the vaccine in residual amounts, a sufficiently sensitive method for its detection and quantification needs to be defined. Two methods for determination of Triton X-100 residuals were developed: the UV-spectrophotometry and HPLC methods. For both methods, preparation of vaccine samples and removal of proteins and virus particles were crucial: samples were treated with methanol (1:1) and then centrifuged at 25 000 × g for 30 min. After such treatment, the majority of vaccine components that interfered in the UV region were removed, and diluted samples could be directly measured. The chromatographic system included C18 column, step methanol gradient, and detection at 225 nm with a single peak of Triton X-100 at 12.6 min. Both methods were validated and gave satisfactory results for accuracy, precision, specificity, linearity, and robustness. LOQ was slightly lower for the HPLC method. Hence, it was shown that both methods are suitable for analysis of residual amounts of Triton X-100, with the advantages of the UV method being its simplicity and availability in most laboratories.

  16. Direct UV Spectrophotometry and HPLC Determination of Triton X-100 in Split Virus Influenza Vaccine.

    PubMed

    Pavlović, Bojana; Cvijetić, Nataša; Dragačević, Luka; Ivković, Branka; Vujić, Zorica; Kuntić, Vesna

    2016-01-01

    One of the most commonly used surfactants in the production of split virus influenza vaccine is nonionic surfactant Triton X-100. After splitting of the virus is accomplished, Triton X-100 is removed from the vaccine by subsequent production steps. Because of toxicity of Triton X-100, which remains in the vaccine in residual amounts, a sufficiently sensitive method for its detection and quantification needs to be defined. Two methods for determination of Triton X-100 residuals were developed: the UV-spectrophotometry and HPLC methods. For both methods, preparation of vaccine samples and removal of proteins and virus particles were crucial: samples were treated with methanol (1:1) and then centrifuged at 25 000 × g for 30 min. After such treatment, the majority of vaccine components that interfered in the UV region were removed, and diluted samples could be directly measured. The chromatographic system included C18 column, step methanol gradient, and detection at 225 nm with a single peak of Triton X-100 at 12.6 min. Both methods were validated and gave satisfactory results for accuracy, precision, specificity, linearity, and robustness. LOQ was slightly lower for the HPLC method. Hence, it was shown that both methods are suitable for analysis of residual amounts of Triton X-100, with the advantages of the UV method being its simplicity and availability in most laboratories. PMID:26960682

  17. Determination of Oxytetracycline from Salmon Muscle and Skin by Derivative Spectrophotometry.

    PubMed

    Toral, M Inés; Sabay, Tamara; Orellana, Sandra L; Richter, Pablo

    2015-01-01

    A method was developed for the identification and quantification of oxytetracycline residues present in salmon muscle and skin using UV-Vis derivative spectrophotometry. With this method, it was possible to reduce the number of steps in the procedure typically required for instrumental analysis of a sample. The spectral variables, order of the derivative, scale factor, smoothing factor, and analytical wavelength were optimized using standard solutions of oxytetracycline dissolved in 900 mg/L oxalic acid in methanol. The matrix effect was significant; therefore, quantification for oxytetracycline residues was carried out using drug-free salmon muscle and skin samples fortified with oxytetracycline. The LOD and LOQ were found to be 271 and 903 μg/kg, respectively. The precision and accuracy of the method were validated using drug-free salmon muscle and skin tissues fortified at three different concentrations (8, 16, and 32 mg/kg) on 3 different days. The recoveries at all fortified concentrations were between 90 and 105%, and RSDs in all cases were less than 6.5%. This method can be used to screen out compliant samples and thereby reduce the number of suspect positive samples that will require further confirmatory analysis. PMID:26025109

  18. Determination of miconazole in pharmaceutical creams using internal standard and second derivative spectrophotometry.

    PubMed

    Wróbel, K; Wróbel, K; de la Garza Rodríguez, I M; López-de-Alba, P L; López-Martínez, L

    1999-06-01

    A simple method is proposed for miconazole determination in pharmaceutical creams, based on extraction and second derivative spectrophotometry. In the presence of sodium lauryl sulfate (0.5%) and sulphuric acid (0.4 mol l(-1)), the miconazole and internal standard (IS) (methylene blue) were extracted to 100 microl of methylene chloride. The organic phase was evaporated in the nitrogen stream and the dry residue was dissolved in methanol (1.5 ml). The analytical signal was obtained as the ratio between second derivative absorbances measured at 236.9 nm (miconazole) and at 663.2 nm (IS). The use of IS in such multi-stage procedure enabled quite good analytical performance in calibration range 50.0 400 mg l(-1): linear correlation coefficient 0.9995, precision (measured as CV for ten replicates) at 50.0 mg l(-1) and at 400 mg l(-1) of miconazole was 1.5 and 0.5% respectively. Four commercial pharmaceutical creams were analyzed and the results obtained were in good agreement with the results obtained by reversed-phase high performance liquid chromatography (HPLC).

  19. Feasibility of spectro-photometry in X-rays (SPHINX) from the moon

    NASA Astrophysics Data System (ADS)

    Sarkar, Ritabrata; Chakrabarti, Sandip Kumar

    2010-08-01

    Doing space Astronomy on lunar surface has several advantages. We present here feasibility of an All Sky Monitoring Payload for Spectro-photometry in X-rays (SPHINX) which can be placed on a lander on the moon or in a space craft orbiting around the moon. The Si-PIN photo-diodes and CdTe crystals are used to detect solar flares, bright gamma bursts, soft gamma-ray repeaters from space and also X-ray fluorescence (XRF) from lunar surface. We present the complete Geant4 simulation to study the feasibility of such an instrument in presence of Cosmic Diffused X-Ray Background (CDXRB). We find that the signal to noise ratio is sufficient for moderate to bright GRBs (above 5 keV), for the quiet sun (up to 100 keV), solar flares, soft gamma-ray repeaters, X-ray Fluorescence (XRF) of lunar surface etc. This is a low-cost system which is capable of performing multiple tasks while stationed at the natural satellite of our planet.

  20. Fast characterization of non domestic load in urban wastewater networks by UV spectrophotometry.

    PubMed

    Baurès, Estelle; Hélias, Emmanuelle; Junqua, Guillaume; Thomas, Olivier

    2007-09-01

    Urban wastewater treatment plant efficiency, as well as biosolid quality, depends on urban wastewater quality, which can be affected by non domestic discharges (industrial, commercial etc.). The characterization of wastewater quality and non domestic discharge is complex, expensive and time consuming. However, these discharges must be controlled and reduced if possible. The development of a simple and fast methodology, namely based on alternative methods such as UV spectrophotometry, has been carried out and applied to different areas of a medium sized town of Southern Québec (Canada). Several autosamplers and on line/on site measurements have been used in critical control points of the network areas, for a dry weather campaign in four areas (industrial, commercial, hospital and university). The flow rate study, completed by the exploitation of conductivity measurements and the qualitative examination of UV spectra allows the discrimination of non domestic loads and their variability study from one point to another. The identification of critical discharges and organic shock loads has been possible with low investment, and mitigation actions have been proposed. PMID:17726556

  1. Determination of myoglobin based on its enzymatic activity by stopped-flow spectrophotometry

    NASA Astrophysics Data System (ADS)

    Zheng, Qi; Liu, Zhihong; Cai, Ruxiu

    2005-04-01

    A new method has been developed for the determination of myoglobin (Mb) based on its enzymatic activity for the oxidation of o-phenylenediamine (OPDA) with hydrogen peroxide. Stopped-flow spectrophotometry was used to study the kinetic behavior of the oxidation reaction. The catalytic activity of Mb was compared to other three kinds of catalyst. The time dependent absorbance of the reaction product, 2,3-diamimophenazine (DAPN), at a wavelength of 426 nm was recorded. The initial reaction rate obtained at 40 °C was found to be proportional to the concentration of Mb in the range of 1.0 × 10 -6 to 4.0 × 10 -9 mol L -1. The detection limit of Mb was found to be 9.93 × 10 -10 mol L -1. The relative standard deviations were within 5% for the determination of different concentrations of Mb. Excess of bovine serum albumin (BSA), Ca(II), Mg(II), Cu(II), glucose, caffeine, lactose and uric acid did not interfere.

  2. Tissue spectrophotometry and thermographic imaging applied to routine clinical prediction of amputation level viability

    NASA Astrophysics Data System (ADS)

    Hanson, Jon M.; Harrison, David K.; Hawthorn, Ian E.

    2002-06-01

    About 5% of British males over 50 years develop peripheral arterial occlusive disease. Of these about 2% ultimately require lower limb amputation. In 1995 we proposed a new technique using lightguide spectrophotometry to measure the oxygen saturation level of haemoglobin (SO2) in the skin as a method for predicting tissue viability. This technique, in combination with thermographic imaging, was compared with skin blood flow measurements using the I125)4- Iodoantipyrine (IAP) clearance technique. The optical techniques gave a sensitivity and selectivity of 1.0 for the prediction of successful outcome of a below knee amputation compared with a specificity of 93% using the traditional IAP technique at a below knee to above knee amputation ratio (BKA:AKA) of 75%. The present study assesses the routine clinical application of these optical techniques. The study is ongoing, but the data to date comprises 22 patients. 4 patients were recommended for above knee amputation (AKA) and 18 patients for below knee amputation on the basis of thermographic and tissue SO2 measurements. All but one of the predicted BKA amputations healed. The study to date produces evidence of 94% healing rate (specificity) for a BKA:AKA ratio of 82%. This compares favorably with the previous figures given above.

  3. Spectrophotometry of the galaxies and nebulosity associated with the quasar III Zw 2

    NASA Technical Reports Server (NTRS)

    Green, R. F.; Williams, T. B.; Morton, D. C.

    1978-01-01

    Results are presented for spectrophotometry of the object III Zw 2, the faint nebulosity to the NW of its nucleus, and two associated galaxies (a normal elliptical and a more luminous late-type spiral). The object III Zw 2 is defined to be a quasar on the basis of its dominant starlike nucleus, redshift, and optical and radio variability. The spectrophotometrically measured redshifts of the two associated galaxies are shown to place III Zw 2 as a member of Zwicky Cluster 0007.7+1056, thus establishing the cosmological origin of the quasar's emission-line redshift of 0.089. It is found that the nebulosity to the NW of the quasar exhibits an emission-line spectrum at the same redshift as the nucleus with an underlying red continuum, that the strength of the forbidden lines relative to the permitted lines is 3 to 4 times greater than in the nucleus, and that the data for the nebulosity are not well fitted by a bremsstrahlung emission spectrum, but are consistent with a spectrum of starlight from an underlying galaxy at the system redshift of 0.089.

  4. Determination of Trace Mercury by Cloud Point Extraction Preconcentration Coupled with Spectrophotometry

    NASA Astrophysics Data System (ADS)

    Sohrabi, Mahmoud Reza; Farokhi, Elham; Adnani, Atena; Ziaian, Mona

    A new micell-mediated phase separation method for preconcentration of ultra-trace quantities of mercury as a prior step to its determination spectrophotometry has been developed. The method is based on the Cloud Point Extraction (CPE) of mercury with Triton X-100 in the absence of chelating agent. Mercury react with sodium diethyldithiocarbamate (DDTC) in a surfactant solution yielding a hydrophobic complex, which then is entrapped in surfactant micelles. Separation of the two phases was accomplished by centrifugation for 10 min at 4000 rpm. Under the optimum conditions i.e., pH 9.0, cloud point temperature 45°C, [DDTC] = 1.6x10-5 mol L-1, [Triton X-114] = 0.032%. Analytical graphs were rectilinear in the concentration range of 4-240 µg L-1 and relative standard deviation for five replicate determinations of Mercury at 8 (μg L-1) concentration level, were 1.9%, respectively (n = 5, c = 8 µg L-1).

  5. Fiber optic spectrophotometry for monitoring dissolved oxygen in a tropical ornamental fish tank environment

    NASA Astrophysics Data System (ADS)

    Asundi, Anand K.; Chen, Jun-Wei; He, Duo-Min

    1999-05-01

    Using Fiber Optic Spectro-Photometry (FOSP) methodology, a set of high sensitivity fiber optic oxygen monitoring system performing NDT is developed for fish farming environment. The working principle of the sensor is based on the detection signal at a particular wavelength due to the fluorescence and quenching of coated dye (ruthenium complex) in response to oxygen concentration at the tip of the probe. This paper looks into the application of fiber optics oxygen sensor in an aquatic environment. A comparison study of the optical probe was made with a conventional electrochemical oxygen sensor. Both sensors were setup to monitor the dissolved oxygen of an aquatic system for a period of time. This new methodology offers an alternative choice for monitoring dissolved oxygen. Apart from the possibility to miniaturize the monitoring equipment for aquatic environment, it is also feasible to 'bundle' other chemical sensors together into one single cable, thus achieving compactness, effectiveness and yet without forgoing whatever the traditional electrochemical sensors could offer.

  6. Influence of medium and temperature on the hydrolysis kinetics of propacetamol hydrochloride: determination using derivative spectrophotometry.

    PubMed

    Barcia, Emilia; Martin, Alicia; Azuara, Ma Luz; Negro, Sofia

    2005-03-01

    Propacetamol hydrochloride (PRO) is a water-soluble prodrug of paracetamol (PA) which can be parenterally administered as analgesic for the treatment of postoperative pain, acute trauma, and gastric and/or intestinal disorders where oral administration is not possible. In these circumstances, PRO can be administered in physiologic or glucose solutions since it is rapidly and quantitatively hydrolyzed into PA by plasma estearases. We have studied the degradation kinetics of PRO in 5% glucose and 0.9% saline solutions at 4 degrees C and 25 degrees C (storage and room temperatures, respectively). The analytic technique used to determine PRO and PA quantitatively was first-derivative spectrophotometry. The degradation process of PRO can be best fitted to a second-order kinetics with independence of the medium used (saline or glucose solution). The hydrolysis kinetics of PRO conversion into PA depends on the temperature but not on the assay medium (saline or glucose solution). The degradation rate constants obtained for PRO were approximately 4.5 times higher at 25 degrees C than at 4 degrees C. The values of t(90%) for PRO were 3.17 h and 3.61 h at 25 degrees C, and 13.42 h and 12.36 h at 4 degrees C when the tests were performed in 5% glucose and 0.9% saline solutions, respectively. PMID:15744097

  7. Measurement of mucosal capillary hemoglobin oxygen saturation in the colon by reflectance spectrophotometry

    NASA Astrophysics Data System (ADS)

    Friedland, Shai; Benaron, David A.; Parachikov, Ilian H.; Soetikno, Roy

    2003-06-01

    Advances in optical and computer technology have enabled the development of a device that utilizes white-light reflectance spectrophotometry to measure capillary hemoglobin saturation in intestinal mucosa during colonoscopy. Studies were performed using the colon oximeter in anesthetized animals and patients undergoing colonoscopy. Mucosal hemoglobin saturation in the normal colon (mean +/- S.D.) is 72% +/- 3.5%. In an animal model, ischemia via arterial ligation and hypoxemia via hypoxic ventilation each result in a decrease of over 40% in the mucosal saturation. In human patients with colon polyps, ischemia induced by epinephrine injection, stalk ligation using a loop, or clipping of the polyp stalk each result in a decrease of over 40% in the mucosal saturation (p<0.02). In contrast, saline injection does not decrease the mucosal saturation (p=N.S.). A patient who previously underwent partial colectomy with sacrifice of the inferior mesenteric artery had a saturation of 55% in the remaining sigmoid colon, with normal values in the superior mesenteric artery territory (p<0.05). A novel device for measuring capillary hemoglobin saturation in intestinal mucosa during colonoscopy is capable of providing reproducible measurements in normal patients and clearly detects dramatic decreases in saturation with ischemic and hypoxic insults.

  8. Application of response surface methodology for determination of methyl red in water samples by spectrophotometry method.

    PubMed

    Khodadoust, Saeid; Ghaedi, Mehrorang

    2014-12-10

    In this study a rapid and effective method (dispersive liquid-liquid microextraction (DLLME)) was developed for extraction of methyl red (MR) prior to its determination by UV-Vis spectrophotometry. Influence variables on DLLME such as volume of chloroform (as extractant solvent) and methanol (as dispersive solvent), pH and ionic strength and extraction time were investigated. Then significant variables were optimized by using a Box-Behnken design (BBD) and desirability function (DF). The optimized conditions (100μL of chloroform, 1.3mL of ethanol, pH 4 and 4% (w/v) NaCl) resulted in a linear calibration graph in the range of 0.015-10.0mgmL(-1) of MR in initial solution with R(2)=0.995 (n=5). The limits of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.015mgmL(-1), respectively. Finally, the DLLME method was applied for determination of MR in different water samples with relative standard deviation (RSD) less than 5% (n=5).

  9. Photodegradation study of nystatin by UV-Vis spectrophotometry and chemometrics modeling.

    PubMed

    Hemmateenejad, Bahram; Nekoeinia, Mohsen; Absalan, Ghodratollah; Ansari, Mehdi

    2014-01-01

    Nystatin, one of the tetraene antifungal antibiotics, is very sensitive to light. Thus, when nystatin is exposed to natural daylight, it is photodegraded to products of lower biological activity. In this work, the photodegradation kinetics of nystatin was monitored by a UV-Vis spectrophotometry method. The absorbance spectra of the nystatin, exposed to a 366 nm UV lamp, were recorded at different periods of time. By application of factor analysis to the absorbance data matrix, three absorbing chemical species, coexisting in the reaction system, were detected. The soft-modeling multivariate curve resolution-alternating least squares analysis of the evolutionary absorbance data revealed that nystatin undergoes photodegradation in a two-step consecutive manner. Hard-modeling data analysis suggested that reaction has first-order kinetics in the first step and zero-order kinetics in the second step. The reaction rate constants of the first and second steps were estimated as 0.0929 (+/-0.0076) and 0.0052 (+/-0.0016)/min, respectively. Finally, the pure spectra of the resolved chemical species were calculated.

  10. Determination of Oxytetracycline from Salmon Muscle and Skin by Derivative Spectrophotometry.

    PubMed

    Toral, M Inés; Sabay, Tamara; Orellana, Sandra L; Richter, Pablo

    2015-01-01

    A method was developed for the identification and quantification of oxytetracycline residues present in salmon muscle and skin using UV-Vis derivative spectrophotometry. With this method, it was possible to reduce the number of steps in the procedure typically required for instrumental analysis of a sample. The spectral variables, order of the derivative, scale factor, smoothing factor, and analytical wavelength were optimized using standard solutions of oxytetracycline dissolved in 900 mg/L oxalic acid in methanol. The matrix effect was significant; therefore, quantification for oxytetracycline residues was carried out using drug-free salmon muscle and skin samples fortified with oxytetracycline. The LOD and LOQ were found to be 271 and 903 μg/kg, respectively. The precision and accuracy of the method were validated using drug-free salmon muscle and skin tissues fortified at three different concentrations (8, 16, and 32 mg/kg) on 3 different days. The recoveries at all fortified concentrations were between 90 and 105%, and RSDs in all cases were less than 6.5%. This method can be used to screen out compliant samples and thereby reduce the number of suspect positive samples that will require further confirmatory analysis.

  11. [Mutual Effect on Determination of Gibberellins and Glyphosate in Groundwater by Spectrophotometry].

    PubMed

    Zhang, Li; Chen, Liang; Liu, Fei

    2015-04-01

    In the present study, a spectrophotometry method for the simultaneous determination of gibberellins (GA3) and glyphosate in groundwater was established and optimized. In addition, the mutual effect on simultaneous determination of GA3 and glyphosate was studied. Based on the experiment, good linearity (R2 > 0.99) was obtained for GA3 in the range of 0-20 and 0-100 µg and for glyphosate in the range of 0-8 and 5-15 µg. The method's detection limit (MDL) of GA3 and glyphosate was 0.48 and 0.82 µg, respectively; and the recovery rates of 15 to 150 µg GA3 and 3 to 10 µg glyphosate in all samples at a spiked level were 71.3% ± 1.9% and 98.4% ± 8.1%, respectively. No obvious influence of glyphosate (0-100 mg · L(-1)) on the recovery rates of GA3 was observed, but the presence of glyphosate could cause slight determination precision decrease of GA3. Meanwhile, adding 2 mg · L(-1) GA3 can increase the recovery rate of glyphosate.

  12. Application of response surface methodology for determination of methyl red in water samples by spectrophotometry method

    NASA Astrophysics Data System (ADS)

    Khodadoust, Saeid; Ghaedi, Mehrorang

    2014-12-01

    In this study a rapid and effective method (dispersive liquid-liquid microextraction (DLLME) was developed for extraction of methyl red (MR) prior to its determination by UV-Vis spectrophotometry. Influence variables on DLLME such as volume of chloroform (as extractant solvent) and methanol (as dispersive solvent), pH and ionic strength and extraction time were investigated. Then significant variables were optimized by using a Box-Behnken design (BBD) and desirability function (DF). The optimized conditions (100 μL of chloroform, 1.3 mL of ethanol, pH 4 and 4% (w/v) NaCl) resulted in a linear calibration graph in the range of 0.015-10.0 mg mL-1 of MR in initial solution with R2 = 0.995 (n = 5). The limits of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.015 mg mL-1, respectively. Finally, the DLLME method was applied for determination of MR in different water samples with relative standard deviation (RSD) less than 5% (n = 5).

  13. Solar selective absorption coatings

    DOEpatents

    Mahoney, Alan R.; Reed, Scott T.; Ashley, Carol S.; Martinez, F. Edward

    2004-08-31

    A new class of solar selective absorption coatings are disclosed. These coatings comprise a structured metallic overlayer such that the overlayer has a sub-micron structure designed to efficiently absorb solar radiation, while retaining low thermal emissivity for infrared thermal radiation. A sol-gel layer protects the structured metallic overlayer from mechanical, thermal, and environmental degradation. Processes for producing such solar selective absorption coatings are also disclosed.

  14. Solar selective absorption coatings

    DOEpatents

    Mahoney, Alan R.; Reed, Scott T.; Ashley, Carol S.; Martinez, F. Edward

    2003-10-14

    A new class of solar selective absorption coatings are disclosed. These coatings comprise a structured metallic overlayer such that the overlayer has a sub-micron structure designed to efficiently absorb solar radiation, while retaining low thermal emissivity for infrared thermal radiation. A sol-gel layer protects the structured metallic overlayer from mechanical, thermal, and environmental degradation. Processes for producing such solar selective absorption coatings are also disclosed.

  15. Optical absorption measurement system

    DOEpatents

    Draggoo, Vaughn G.; Morton, Richard G.; Sawicki, Richard H.; Bissinger, Horst D.

    1989-01-01

    The system of the present invention contemplates a non-intrusive method for measuring the temperature rise of optical elements under high laser power optical loading to determine the absorption coefficient. The method comprises irradiating the optical element with a high average power laser beam, viewing the optical element with an infrared camera to determine the temperature across the optical element and calculating the absorption of the optical element from the temperature.

  16. Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples

    NASA Technical Reports Server (NTRS)

    Malik, W. M.

    1967-01-01

    Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.

  17. Seven-effect absorption refrigeration

    DOEpatents

    DeVault, R.C.; Biermann, W.J.

    1989-05-09

    A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit. 1 fig.

  18. Seven-effect absorption refrigeration

    DOEpatents

    DeVault, Robert C.; Biermann, Wendell J.

    1989-01-01

    A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit.

  19. Selective coherent perfect absorption in metamaterials

    SciTech Connect

    Nie, Guangyu; Shi, Quanchao; Zhu, Zheng; Shi, Jinhui

    2014-11-17

    We show multi-band coherent perfect absorption (CPA) in simple bilayered asymmetrically split ring metamaterials. The selectivity of absorption can be accomplished by separately excited electric and magnetic modes in a standing wave formed by two coherent counterpropagating beams. In particular, each CPA can be completely switched on/off by the phase of a second coherent wave. We propose a practical scheme for realizing multi-band coherent perfect absorption of 100% that is allowed to work from microwave to optical frequency.

  20. Electric modulation of optical absorption in nanowires

    NASA Astrophysics Data System (ADS)

    Sakr, M. R.

    2016-11-01

    We have calculated the effect of an external electric field on the intersubband optical absorption of a nanowire subjected to a perpendicular magnetic field and Rashba effect. The absorption peaks due to optical transitions that are forbidden in the absence of the intersubband coupling experience strong amplitude modulation. This effect is quadratic in electric fields applied along the direction of quantum confinement or perpendicularly to tune the Rashba parameter. The electric field also induces frequency modulation in the associated spectrum. On the other hand, transitions that are normally allowed show, to a large extent, a parallel band effect, and accordingly they are responsible for strong optical absorption.

  1. Total absorption by degenerate critical coupling

    SciTech Connect

    Piper, Jessica R. Liu, Victor; Fan, Shanhui

    2014-06-23

    We consider a mirror-symmetric resonator with two ports. We show that, when excited from a single port, complete absorption can be achieved through critical coupling to degenerate resonances with opposite symmetry. Moreover, any time two resonances with opposite symmetry are degenerate in frequency and absorption is always significantly enhanced. In contrast, when two resonances with the same symmetry are nearly degenerate, there is no absorption enhancement. We numerically demonstrate these effects using a graphene monolayer on top of a photonic crystal slab, illuminated from a single side in the near-infrared.

  2. Absorption of planar waves in a draining bathtub

    SciTech Connect

    Oliveira, Ednilton S.; Dolan, Sam R.; Crispino, Luis C. B.

    2010-06-15

    We present an analysis of the absorption of acoustic waves by a black hole analogue in (2+1) dimensions generated by a fluid flow in a draining bathtub. We show that the low-frequency absorption length is equal to the acoustic hole circumference and that the high-frequency absorption length is 4 times the ergoregion radius. For intermediate values of the wave frequency, we compute the absorption length numerically and show that our results are in excellent agreement with the low- and high-frequency limits. We analyze the occurrence of superradiance, manifested as negative partial absorption lengths for corotating modes at low frequencies.

  3. Absorption mapping for characterization of glass surfaces.

    PubMed

    Commandré, M; Roche, P; Borgogno, J P; Albrand, G

    1995-05-01

    The surface quality of bare substrates and preparation procedures take on an important role in optical coating performances. The most commonly used techniques of characterization generally give information about roughness and local defects. A photothermal deflection technique is used for mapping surface absorption of fused-silica and glass substrates. We show that absorption mapping gives specific information on surface contamination of bare substrates. We present experimental results concerning substrates prepared by different cleaning and polishing techniques. We show that highly polished surfaces lead to the lowest values of residual surface absorption. Moreover the cleaning behavior of surfaces of multicomponent glasses and their optical performance in terms of absorption are proved to be different from those of fused silica.

  4. FTIR (Fourier transform infrared) spectrophotometry for thin film monitors: Computer and equipment integration for enhanced capabilities

    SciTech Connect

    Cox, J.N.; Sedayao, J.; Shergill, G.; Villasol, R. ); Haaland, D.M. )

    1990-01-01

    Fourier transform infrared spectrophotometry (FTIR) is a valuable technique for monitoring thin films used in semiconductor device manufacture. Determinations of the constituent contents in borophosphosilicate (BPSG), phosphosilicate (PSG), silicon oxynitride (SiON:H,OH), and spin-on-glass (SOG) thin films are a few applications. Due to the nature of the technique, FTIR instrumentation is one of the most extensively computer-dependent pieces of equipment that is likely to be found in a microelectronics plant. In the role of fab monitor or reactor characterization tool, FTIR instruments can rapidly generate large amounts of data. By linking a local FTIR data station to a remote minicomputer its capabilities are greatly improved. We discuss three caused of enhancement. First, the FTIR in the fab area communicates and interacts in real time with the minicomputer: transferring data segments to it, instructing it to perform sophisticated processing, and returning the result to the operator in the fab. Characterizations of PSG thin films by this approach are discussed. Second, the spectra of large numbers of samples are processed locally. The large database is then transmitted to the minicomputer for study by statistical/graphics software. Results of CVD-reactor spatial profiling experiments for plasma SiON are presented. Third, processing of calibration spectra is performed on the minicomputer to optimize the accuracy and precision of a Partial Least Squares'' analysis mode. This model is then transferred to the data station in the fab. The analysis of BPSG thin films is discussed in this regard. The prospects for fully automated at-line monitoring and for real-time, in-situ monitoring will be discussed. 10 refs., 4 figs.

  5. Determination of crystal violet in water by direct solid phase spectrophotometry after rotating disk sorptive extraction.

    PubMed

    Manzo, Valentina; Navarro, Orielle; Honda, Luis; Sánchez, Karen; Inés Toral, M; Richter, Pablo

    2013-03-15

    The microextraction of crystal violet (CV) from water samples into polydimethylsiloxane (PDMS) using the rotating disk sorptive extraction (RDSE) technique was performed. The extracting device was a small Teflon disk that had an embedded miniature magnetic stirring bar and a PDMS (560 μL) film attached to one side of the disk using double-sided tape. The extraction involves a preconcentration of CV into the PDMS, where the analyte is then directly quantified using solid phase spectrophotometry at 600 nm. Different chemical and extraction device-related variables were studied to achieve the best sensitivity for the determination. The optimum extraction was performed at pH 14 because under this condition, CV is transformed to the neutral and colorless species carbinol, which can be quantitatively transferred to the PDMS phase. Although the colorless species is the chemical form extracted in the PDMS, an intense violet coloration appeared in the phase because the -OH bond in the carbinol molecule is weakened through the formation of hydrogen bonds with the oxygen atoms of the PDMS, allowing the resonance between the three benzene rings to compensate for the charge deficit on the central carbon atom of the molecule. The accuracy and precision of the method were evaluated in river water samples spiked with 10 and 30 μg L(-1) of CV, yielding a relative standard deviation of 6.2% and 8.4% and a recovery of 98.4% and 99.4%, respectively. The method detection limit was 1.8 μg L(-1) and the limit of quantification was 5.4 μg L(-1), which can be decreased if the sample volume is increased.

  6. Estimation of nitrite in source-separated nitrified urine with UV spectrophotometry.

    PubMed

    Mašić, Alma; Santos, Ana T L; Etter, Bastian; Udert, Kai M; Villez, Kris

    2015-11-15

    Monitoring of nitrite is essential for an immediate response and prevention of irreversible failure of decentralized biological urine nitrification reactors. Although a few sensors are available for nitrite measurement, none of them are suitable for applications in which both nitrite and nitrate are present in very high concentrations. Such is the case in collected source-separated urine, stabilized by nitrification for long-term storage. Ultraviolet (UV) spectrophotometry in combination with chemometrics is a promising option for monitoring of nitrite. In this study, an immersible in situ UV sensor is investigated for the first time so to establish a relationship between UV absorbance spectra and nitrite concentrations in nitrified urine. The study focuses on the effects of suspended particles and saturation on the absorbance spectra and the chemometric model performance. Detailed analysis indicates that suspended particles in nitrified urine have a negligible effect on nitrite estimation, concluding that sample filtration is not necessary as pretreatment. In contrast, saturation due to very high concentrations affects the model performance severely, suggesting dilution as an essential sample preparation step. However, this can also be mitigated by simple removal of the saturated, lower end of the UV absorbance spectra, and extraction of information from the secondary, weaker nitrite absorbance peak. This approach allows for estimation of nitrite with a simple chemometric model and without sample dilution. These results are promising for a practical application of the UV sensor as an in situ nitrite measurement in a urine nitrification reactor given the exceptional quality of the nitrite estimates in comparison to previous studies.

  7. CO2 laser light absorption characteristics of metal powders

    NASA Astrophysics Data System (ADS)

    Haag, M.; Hügel, H.; Albright, C. E.; Ramasamy, S.

    1996-04-01

    Absorption characteristics of metal powders for 10.6 μm CO2 laser radiation were examined. Using a calorimetric method, absorptance measurements were performed on four different powder materials, including aluminum, copper, iron, and titanium aluminide. The experimental results showed that laser absorptance depends on powder porosity and material. The measured absorptance values at low laser intensities ranged between 28% and 43%. The titanium aluminide powders showed the highest absorptance values, and aluminum powders the lowest. As laser intensity was increased, the copper and iron powders showed strong signs of oxidation when irradiated in air, resulting in an increase in absorptance. Neither oxidation nor increased absorptance were observed when helium or argon were used as shielding gas.

  8. Polarization control of intermediate state absorption in resonance-mediated multi-photon absorption process

    NASA Astrophysics Data System (ADS)

    Xu, Shuwu; Huang, Yunxia; Yao, Yunhua; Jia, Tianqing; Ding, Jingxin; Zhang, Shian; Sun, Zhenrong

    2015-07-01

    We theoretically and experimentally demonstrate the control of the intermediate state absorption in an (n + m) resonance-mediated multi-photon absorption process by the polarization-modulated femtosecond laser pulse. An analytical solution of the intermediate state absorption in a resonance-mediated multi-photon absorption process is obtained based on the time-dependent perturbation theory. Our theoretical results show that the control efficiency of the intermediate state absorption by the polarization modulation is independent of the laser intensity when the transition from the intermediate state to the final state is coupled by the single-photon absorption, but will be affected by the laser intensity when this transition is coupled by the non-resonant multi-photon absorption. These theoretical results are experimentally confirmed via a two-photon fluorescence control in (2 + 1) resonance-mediated three-photon absorption of Coumarin 480 dye and a single-photon fluorescence control in (1 + 2) resonance-mediated three-photon absorption of IR 125 dye.

  9. Absorption heat pump system

    DOEpatents

    Grossman, Gershon; Perez-Blanco, Horacio

    1984-01-01

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  10. Determination of copper in tap water using solid-phase spectrophotometry

    NASA Technical Reports Server (NTRS)

    Hill, Carol M.; Street, Kenneth W.; Philipp, Warren H.; Tanner, Stephen P.

    1994-01-01

    A new application of ion exchange films is presented. The films are used in a simple analytical method of directly determining low concentrations of Cu(2+) in aqueous solutions, in particular, drinking water. The basis for this new test method is the color and absorption intensity of the ion when adsorbed onto the film. The film takes on the characteristic color of the adsorbed cation, which is concentrated on the film by many orders of magnitude. The linear relationship between absorbance (corrected for variations in film thickness) and solution concentration makes the determinations possible. These determinations agree well with flame atomic absorption determinations.

  11. Spectrophotometry of Pluto-Charon mutual events - Individual spectra of Pluto and Charon

    NASA Technical Reports Server (NTRS)

    Sawyer, S. R.; Barker, E. S.; Cochran, A. L.; Cochran, W. D.

    1987-01-01

    Time-resolved spectra of the March 3 and April 4, 1987 mutual events of Pluto and Charon, obtained with spectral coverage from 5500 to 10,000 A with 25-A spectral resolution, are discussed. Charon has a featureless reflectance spectrum, with no evidence of methane absorption. Charon's reflectance appears neutral in color and corresponds to a geometric albedo of about 0.37 at 6000 A. The Pluto reflectance spectrum displays methane absorption bands at 7300, 7900, 8400, 8600, and 8900 A and is red in color, with a geometric albedo of about 0.56 at 6000 A.

  12. Scanning electron microscopy with energy dispersive X-ray spectrophotometry analysis of reciprocating and continuous rotary nickel-titanium instruments following root canal retreatment.

    PubMed

    Kalyoncuoğlu, Elif; Keskin, Cangül; Uzun, İsmail; Bengü, Aydın S; Guler, Buğra

    2016-01-01

    This study aimed to evaluate superficial defects and the composition of Reciproc R25 and ProTaper Retreatment file systems (Dentsply Maillefer, Ballaigues, Switzerland) used for retreatment. A total of 100 maxillary incisor teeth were randomly divided into the following two groups: Reciproc R25 (n = 25) and ProTaper Retreatment instrument (n = 75) groups. The nickel-titanium (Ni-Ti) compositions of the files before and after use were analyzed using energy dispersive X-ray spectrophotometry (EDX). Chi-square, Mann-Whitney U, and Kruskal-Wallis tests were used to analyze the data. ProTaper Retreatment instrument group showed a significantly higher number of defects than the Reciproc group (P < 0.05). No instrument fracture was detected. The presence of debris was observed in both groups before use, although the level was significantly higher in the ProTaper Retreatment group, which consisted of metals (P < 0.05). There was no significant difference between new and used instruments with regard to Ni-Ti composition (P < 0.05). EDX analysis showed that both the Reciproc and ProTaper Retreatment instruments had a Ni-Ti composition that was within the standards specified by the American Society of Testing and Materials. This study confirmed the use of both the Reciproc R25 file and ProTaper Retreatment file system for root canal filling removal in straight root canals as a safe procedure. (J Oral Sci 58, 401-406, 2016). PMID:27665980

  13. Plan Showing Cross Bracing Under Upper Stringers, Typical Section Showing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Plan Showing Cross Bracing Under Upper Stringers, Typical Section Showing End Framing, Plan Showing Cross Bracing Under Lower Stringers, End Elevation - Covered Bridge, Spanning Contoocook River, Hopkinton, Merrimack County, NH

  14. Lipids: Absorption and transport

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Due to the hydrophobic nature of lipids, dietary fat is handled differently than protein or carbohydrate with respect with digestion and absorption. Dietary fats are broken down throughout the gastrointestinal system. A unique group of enzymes and cofactors allows this process to proceed in an eff...

  15. Two-Phonon Absorption

    ERIC Educational Resources Information Center

    Hamilton, M. W.

    2007-01-01

    A nonlinear aspect of the acousto-optic interaction that is analogous to multi-photon absorption is discussed. An experiment is described in which the second-order acousto-optically scattered intensity is measured and found to scale with the square of the acoustic intensity. This experiment using a commercially available acousto-optic modulator is…

  16. Cholesterol Absorption and Metabolism.

    PubMed

    Howles, Philip N

    2016-01-01

    Inhibitors of cholesterol absorption have been sought for decades as a means to treat and prevent cardiovascular diseases (CVDs) associated with hypercholesterolemia. Ezetimibe is the one clear success story in this regard, and other compounds with similar efficacy continue to be sought. In the last decade, the laboratory mouse, with all its genetic power, has become the premier experimental model for discovering the mechanisms underlying cholesterol absorption and has become a critical tool for preclinical testing of potential pharmaceutical entities. This chapter briefly reviews the history of cholesterol absorption research and the various gene candidates that have come under consideration as drug targets. The most common and versatile method of measuring cholesterol absorption is described in detail along with important considerations when interpreting results, and an alternative method is also presented. In recent years, reverse cholesterol transport (RCT) has become an area of intense new interest for drug discovery since this process is now considered another key to reducing CVD risk. The ultimate measure of RCT is sterol excretion and a detailed description is given for measuring neutral and acidic fecal sterols and interpreting the results. PMID:27150091

  17. Determination of ibuprofen in combined dosage forms and cream by direct UV spectrophotometry after solid-phase extraction.

    PubMed

    Sunaric, Slavica; Petkovic, Milica; Denic, Marko; Mitic, Snezana; Pavlovic, Aleksandra

    2013-01-01

    Solid-phase extraction method followed by direct UV spectrophotometry at 264 nm was developed and applied for the selective ibuprofen determination in two-component formulation of ibuprofen and pseudoephedrine-HCl, combined powder which contains ibuprofen in the form of salt with L-arginine and 10% ibuprofen cream. Procedures for ibuprofen determination in complex pharmaceutical preparations by direct UV spectrophotometry lack selectivity because of interferences of other active substances and fat components. A limited number of spectrophotometric methods applicable to these samples are based on derivative (first and second-order) UV spectroscopy. Common HPLC procedures are more selective but more expensive and for creams also require some type of extraction because the large amount of oily excipients would clog up the column. The proposed solid-phase extraction method proved to be suitable for analysis of ibuprofen in combined tablets, powders and creams by direct UV spectrophotometry. Also the method provides an effective clean-up of the cream and allows ibuprofen determination by HPLC analysis. For the extraction three different commercial sorbents were tested: anion exchange Oasis MAX, hydrophilic-lipophilic balanced Oasis HLB and reverse-phase Chromabond C18ec. The optimization of the SPE method was first done on standard ibuprofen solutions and then the suitability of the method was checked on solutions of commercial pharmaceutical samples. The method yields good results for all three types of commercial preparations on the anion-exchange Oasis MAX cartridges, with recoveries of 90-100.2%. The interferences in UV analysis were not registered and good precision (RSD < 6%) was obtained. The present method has been verified as accurate as the reference HPLC with the great advantage of less expensive instrumentation. For this reason, the method would be suitable for a routine and rapid drug quality control.

  18. Extraordinary Optical Absorption through Plasmonic Subwavelength Slits

    NASA Astrophysics Data System (ADS)

    White, Justin; Veronis, Georgios; Yu, Zongfu; Barnard, Edward; Chandran, Anu; Fan, Shanhui; Brongersma, Mark

    2009-03-01

    We report on the ability of resonant plasmonic slits to efficiently concentrate electromagnetic energy into a nanoscale volume of absorbing material placed inside or right behind the slit. This gives rise to extraordinary optical absorption (EOA) characterized by an absorption enhancement factor that well-exceeds the enhancements seen for extraordinary optical transmission (EOT) through slits. A semi-analytic Fabry-Perot model for the resonant absorption is developed and shown to quantitatively agree with full-field simulations. We show that absorption enhancements of nearly 1000% can be realized at 633nm for slits in aluminum films filled with silicon. This effect can be utilized in a wide range of applications, including high speed photodetectors, optical lithography and recording, and biosensors.

  19. Substrate effects on absorption of coated surfaces.

    PubMed

    Roche, P; Commandré, M; Escoubas, L; Borgogno, J P; Albrand, G; Lazaridνs, B

    1996-09-01

    Photothermal deflection is used for mapping the absorption of bare and coated surfaces. The same area is mapped before and after coating and also after annealing. The great importance of the substrate with respect to the total losses of the coated component is emphasized. First the influence of surface contamination of the bare substrate on the total absorption of the coated substrate is studied for BK7 and fused-silica substrates. Then the mean value of the coated-substrate absorptance is shown to be strongly dependenton the type of substrate. Experimental results show that this effect is associated with a localization of the absorption at the near surface of the substrate and at the interfaces of the film.

  20. The origin of the excess transit absorption in the HD 189733 system: planet or star?

    NASA Astrophysics Data System (ADS)

    Barnes, J. R.; Haswell, C. A.; Staab, D.; Anglada-Escudé, G.

    2016-10-01

    We have detected excess absorption in the emission cores of Ca II H&K during transits of HD 189733b for the first time. Using observations of three transits, we investigate the origin of the absorption, which is also seen in Hα and the Na I D lines. Applying differential spectrophotometry methods to the Ca II H and Ca II K lines combined, using respective passband widths of Δλ = 0.4 and 0.6 Å yields excess absorption of td = 0.0074 ± 0.0044 (1.7σ; Transit 1) and 0.0214 ± 0.0022 (9.8σ; Transit 2). Similarly, we detect excess Hα absorption in a passband of width Δλ = 0.7 Å, with td = 0.0084 ± 0.0016 (5.2σ) and 0.0121 ± 0.0012 (9.9σ). For both lines, Transit 2 is thus significantly deeper. Combining all three transits for the Na I D lines yields excess absorption of td = 0.0041 ± 0.0006 (6.5σ). By considering the time series observations of each line, we find that the excess apparent absorption is best recovered in the stellar reference frame. These findings lead us to postulate that the main contribution to the excess transit absorption in the differential light curves arises because the normalizing continuum bands form in the photosphere, whereas the line cores contain a chromospheric component. We cannot rule out that part of the excess absorption signature arises from the planetary atmosphere, but we present evidence which casts doubt on recent claims to have detected wind motions in the planet's atmosphere in these data.

  1. [Determination of the initial stage of fat auto-oxidation in dry dairy products by ultraviolet spectrophotometry].

    PubMed

    Bruchkova, S I

    1976-01-01

    Studied were the values of the conjugated dienes using ultraviolet spectrophotometry of fats contained in the dry dairy products produced in this country, such as powdered milk for children, Vitalakt 1, Bébé 1, and Biolakton in the first months of storage. It was found that the extinction maximum values characteristic of the conjugated dienes for the fats of all studied dry milk products were at 227 nm. The juxtaposition of changes taking place with conjugated dienes and peroxide numbers of the fats during storage revealed the greater stability of conjugated dienes in comparison with the hydroperoxides.

  2. Determination of vitamin B6 by means of differential spectrophotometry in pharmaceutical preparations in the presence of magnesium compounds.

    PubMed

    Muszalska, Izabela; Puchalska, Marta; Sobczak, Agnieszka

    2011-01-01

    The content of pyridoxine hydrochloride in two-component pharmaceutical preparations containing various magnesium compounds was examined. The UV differentiation spectrophotometry was devised and compared with the reference method of high performance liquid chromatography (HPLC). The analysis of the absorbance spectra (A) and its first (D1) and second (D2) derivatives made it possible to establish the appropriate analytical wavelengths (A: 290 nm; D1: 302 nm; D2: 308 nm). It was proved that spectrum differentiation significantly corrects errors resulting from overlapping background especially when the magnesium hydroaspartate, lactate or magnesium lactogluconate is present together with vitamin B6.

  3. New methods for determination of cinnarizine in mixture with piracetam by spectrodensitometry, spectrophotometry, and liquid chromatography.

    PubMed

    Metwally, Fadia H; Elzeany, B A; Darwish, H W

    2005-01-01

    Four new methods were developed and validated for the determination of cinnarizine HCl in its binary mixture with piracetam in pure and pharmaceutical preparations. The first one was a densitometric analysis that provides a simple and rapid method for the separation and quantification of cinnarizine HCI. The method depends on the quantitative densitometric evaluation of thin-layer chromatograms of cinnarizine HCI at 252 nm over concentration range of 1-6 microg/spot, with a mean accuracy of 100.05 +/- 0.91%. The second method was determination of the drug using a colorimetric method that utilizes the reaction of 3-methyl-benzothiazolin-2-one in the presence of FeCl3 as an oxidant. The green color of the resulting product was measured at 630 nm over concentration range 10-40 microg/mL, with a mean accuracy of 100.10 +/- 1.13%. The third method was a direct spectrophotometric determination of cinnarizine HCI at 252 nm over the concentration range 7-20 microg/mL, while piracetam was determined by derivative ratio spectrophotometry at 221.6 nm over concentration range 5-30 microg/mL, with a mean accuracy of 100.14 +/- 0.79 and 100.26 +/- 1.24% for cinnarizine HCI and piracetam, respectively. The last method was a liquid chromatography analysis of both cinnarizine HCI and piracetam, depending on quantitative evaluation of chromatograms of cinnarizine HCI and piracetam at 252 and 212 nm, respectively, over the concentration range 10-200 microg/mL for cinnarizine HCI and 20-500 microg/mL for piracetam, with a mean accuracy of 100.03 +/- 0.89 and 100.40 +/- 0.94% for cinnarizine HCI and piracetam, respectively. The proposed procedures were checked using laboratory-prepared mixtures and successfully applied for the analysis of their pharmaceutical preparations. The validity of the proposed procedures was further assessed by applying the standard addition technique. Recoveries were quantitative, and the results obtained agreed with those obtained by other reported methods

  4. Simultaneous determination of mercury and organic carbon in sediment and soils using a direct mercury analyzer based on thermal decomposition-atomic absorption spectrophotometry.

    PubMed

    Chen, Jingjing; Chakravarty, Pragya; Davidson, Gregg R; Wren, Daniel G; Locke, Martin A; Zhou, Ying; Brown, Garry; Cizdziel, James V

    2015-04-29

    The purpose of this work was to study the feasibility of using a direct mercury analyzer (DMA) to simultaneously determine mercury (Hg) and organic matter content in sediment and soils. Organic carbon was estimated by re-weighing the sample boats post analysis to obtain loss-on-ignition (LOI) data. The DMA-LOI results were statistically similar (p<0.05) to the conventional muffle furnace approach. A regression equation was developed to convert DMA-LOI data to total organic carbon (TOC), which varied between 0.2% and 13.0%. Thus, mercury analyzers based on combustion can provide accurate estimates of organic carbon content in non-calcareous sediment and soils; however, weight gain from moisture (post-analysis), measurement uncertainty, and sample representativeness should all be taken into account. Sediment cores from seasonal wetland and open water areas from six oxbow lakes in the Mississippi River alluvial flood plain were analyzed. Wetland sediments generally had higher levels of Hg than open water areas owing to a greater fraction of fine particles and higher levels of organic matter. Annual loading of Hg in open water areas was estimated at 4.3, 13.4, 19.2, 20.7, 129, and 135 ng cm(-2) yr(-1) for Beasley, Roundaway, Hampton, Washington, Wolf and Sky Lakes, respectively. Generally, the interval with the highest Hg flux was dated to the 1960s and 1970s. PMID:25847156

  5. Trace monitoring of silver ions in food and water samples by flame atomic absorption spectrophotometry after preconcentration with solvent-assisted dispersive solid phase extraction.

    PubMed

    Omidi, Fariborz; Behbahani, Mohammad; Shahtaheri, Seyed Jamaleddin; Salimi, Sara

    2015-06-01

    In this research, a new sample treatment technique termed solvent-assisted dispersive solid phase extraction (SADSPE) was developed. The new method was based on the dispersion of the sorbent into the sample to maximize the contact surface. In this approach, the dispersion of the sorbent at a very low milligram level was achieved by injecting a mixture solution of the sorbent and disperser solvent into the aqueous sample. Thereby, a cloudy solution formed. The cloudy solution resulted from the dispersion of the fine particles of the sorbent in the bulk aqueous sample. After extraction, the cloudy solution was centrifuged and the enriched analytes in the sediment phase dissolved in ethanol and determined by FAAS. Under the optimized conditions, the detection limit for silver ions was 0.8 μg L(-1). The relative standard deviations for six separate extraction experiments for determination of 5 and 200 μg L(-1) of silver ions was 3.4 and 3.1 %. The preconcentration factor was found to be 61.7. SADSPE was successfully applied for trace determination of silver ions in water and food samples.

  6. Preparation of dry extract of Mikania glomerata Sprengel (Guaco) and determination of its coumarin levels by spectrophotometry and HPLC-UV.

    PubMed

    Soares e Silva, Luciana Soares E; da Santos da Silva, Luciane Santos; Brumano, Larissa; Stringheta, Paulo César; Aparecida de Oliveira Pinto, Miriam; Moreira Dias, Leticia Oliveira; de Sá Martins Muller, Camila; Scio, Elita; Fabri, Rodrigo Luiz; Castro, Helena C; da Penha Henriques do Amaral, Maria

    2012-01-01

    Guaco (Mikania glomerata Sprengel) syrup is one of the most popular herbal medicines used to treat the symptoms of asthmatic bronchitis, cough and hoarseness. The coumarin 2H-1-benzopyran-2-one, is one of the major constituents of Guaco and contributes to its pharmacological effects. The pharmaceutical capsule form of dry extract of Guaco is recommended by the Brazilian Program of Medicinal Plants and Herbal Medicines and used in primary health care. In order to identify a new protocol to obtain the raw material for Guaco capsule production we evaluated two methods, including a freezedrying process (lyophilization) and the spray-dryer technique, as well as the use of two adjuvants, Maltodextrins and Aerosil®, in different concentrations. The coumarin levels of the dried extracts were analyzed by UV-spectrophotometry and HPLC-UV/DAD. The adjuvant Aerosil® 8% showed better dry powder physical appearance. Lyophilization was observed to be the best process to obtain the dry extract of Guaco based on the measured coumarin levels. PMID:22932215

  7. 69. INTERIOR VIEW OF THE ABSORPTION TOWER BUILDING, ABSORPTION TOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    69. INTERIOR VIEW OF THE ABSORPTION TOWER BUILDING, ABSORPTION TOWER UNDER CONSTRUCTION. (DATE UNKNOWN). - United States Nitrate Plant No. 2, Reservation Road, Muscle Shoals, Muscle Shoals, Colbert County, AL

  8. Effect of idler absorption in pulsed optical parametric oscillators.

    PubMed

    Rustad, Gunnar; Arisholm, Gunnar; Farsund, Øystein

    2011-01-31

    Absorption at the idler wavelength in an optical parametric oscillator (OPO) is often considered detrimental. We show through simulations that pulsed OPOs with significant idler absorption can perform better than OPOs with low idler absorption both in terms of conversion efficiency and beam quality. The main reason for this is reduced back conversion. We also show how the beam quality depends on the beam width and pump pulse length, and present scaling relations to use the example simulations for other pulsed nanosecond OPOs.

  9. Photothermal absorption correlation spectroscopy.

    PubMed

    Octeau, Vivien; Cognet, Laurent; Duchesne, Laurence; Lasne, David; Schaeffer, Nicolas; Fernig, David G; Lounis, Brahim

    2009-02-24

    Fluorescence correlation spectroscopy (FCS) is a popular technique, complementary to cell imaging for the investigation of dynamic processes in living cells. Based on fluorescence, this single molecule method suffers from artifacts originating from the poor fluorophore photophysics: photobleaching, blinking, and saturation. To circumvent these limitations we present here a new correlation method called photothermal absorption correlation spectroscopy (PhACS) which relies on the absorption properties of tiny nano-objects. PhACS is based on the photothermal heterodyne detection technique and measures akin FCS, the time correlation function of the detected signals. Application of this technique to the precise determination of the hydrodynamic sizes of different functionalized gold nanoparticles are presented, highlighting the potential of this method. PMID:19236070

  10. THE ABSORPTION OF ADRENALIN

    PubMed Central

    Lyon, D. Murray

    1923-01-01

    1. Adrenalin solution given subcutaneously is usually rapidly absorbed, probably by lymphatic channels. 2. The speed of this process may be influenced by the circulation rate. 3. The relative amounts of adrenalin at any moment unabsorbed at the site of inoculation, carried in the circulating fluids, and taken up by the reacting tissues can be calculated from figures extracted from the curve of the blood pressure changes. The relative rates of transference of adrenalin into the blood and from the circulation into the tissues can also be estimated. 4. When absorption takes place rapidly a large quantity of the drug comes into action at once and the maximum occurs early, the curve of blood pressure reaches a considerable height, and subsides quickly. When absorption is slow the apex appears later and does not reach so high a level. 5. The response to adrenalin bears a logarithmic relationship to the dose employed and a method of allowing for this is indicated. PMID:19868816

  11. Relic Neutrino Absorption Spectroscopy

    SciTech Connect

    Eberle, b

    2004-01-28

    Resonant annihilation of extremely high-energy cosmic neutrinos on big-bang relic anti-neutrinos (and vice versa) into Z-bosons leads to sizable absorption dips in the neutrino flux to be observed at Earth. The high-energy edges of these dips are fixed, via the resonance energies, by the neutrino masses alone. Their depths are determined by the cosmic neutrino background density, by the cosmological parameters determining the expansion rate of the universe, and by the large redshift history of the cosmic neutrino sources. We investigate the possibility of determining the existence of the cosmic neutrino background within the next decade from a measurement of these absorption dips in the neutrino flux. As a by-product, we study the prospects to infer the absolute neutrino mass scale. We find that, with the presently planned neutrino detectors (ANITA, Auger, EUSO, OWL, RICE, and SalSA) operating in the relevant energy regime above 10{sup 21} eV, relic neutrino absorption spectroscopy becomes a realistic possibility. It requires, however, the existence of extremely powerful neutrino sources, which should be opaque to nucleons and high-energy photons to evade present constraints. Furthermore, the neutrino mass spectrum must be quasi-degenerate to optimize the dip, which implies m{sub {nu}} 0.1 eV for the lightest neutrino. With a second generation of neutrino detectors, these demanding requirements can be relaxed considerably.

  12. Derivative spectrophotometry for the determination of faropenem in the presence of degradation products: an application for kinetic studies.

    PubMed

    Cielecka-Piontek, Judyta

    2013-07-01

    A simple and selective derivative spectrophotometric method was developed for the quantitative determination of faropenem in pure form and in pharmaceutical dosage. The method is based on the zero-crossing effect of first-derivative spectrophotometry (λ = 324 nm), which eliminates the overlapping effect caused by the excipients present in the pharmaceutical preparation, as well as degradation products, formed during hydrolysis, oxidation, photolysis, and thermolysis. The method was linear in the concentration range 2.5-300 μg/mL (r = 0.9989) at λ = 341 nm; the limits of detection and quantitation were 0.16 and 0.46 μg/mL, respectively. The method had good precision (relative standard deviation from 0.68 to 2.13%). Recovery of faropenem ranged from 97.9 to 101.3%. The first-order rate constants of the degradation of faropenem in pure form and in pharmaceutical dosage were determined by using first-derivative spectrophotometry. A statistical comparison of the validation results and the observed rate constants for faropenem degradation with these obtained with the high-performance liquid chromatography method demonstrated that both were compatible. PMID:23816120

  13. Derivative spectrophotometry for the determination of faropenem in the presence of degradation products: an application for kinetic studies.

    PubMed

    Cielecka-Piontek, Judyta

    2013-07-01

    A simple and selective derivative spectrophotometric method was developed for the quantitative determination of faropenem in pure form and in pharmaceutical dosage. The method is based on the zero-crossing effect of first-derivative spectrophotometry (λ = 324 nm), which eliminates the overlapping effect caused by the excipients present in the pharmaceutical preparation, as well as degradation products, formed during hydrolysis, oxidation, photolysis, and thermolysis. The method was linear in the concentration range 2.5-300 μg/mL (r = 0.9989) at λ = 341 nm; the limits of detection and quantitation were 0.16 and 0.46 μg/mL, respectively. The method had good precision (relative standard deviation from 0.68 to 2.13%). Recovery of faropenem ranged from 97.9 to 101.3%. The first-order rate constants of the degradation of faropenem in pure form and in pharmaceutical dosage were determined by using first-derivative spectrophotometry. A statistical comparison of the validation results and the observed rate constants for faropenem degradation with these obtained with the high-performance liquid chromatography method demonstrated that both were compatible.

  14. Corrosion Problems in Absorption Chillers

    ERIC Educational Resources Information Center

    Stetson, Bruce

    1978-01-01

    Absorption chillers use a lithium bromide solution as the medium of absorption and water as the refrigerant. Discussed are corrosion and related problems, tests and remedies, and cleaning procedures. (Author/MLF)

  15. Color Voyager 2 Image Showing Crescent Uranus

    NASA Technical Reports Server (NTRS)

    1990-01-01

    This image shows a crescent Uranus, a view that Earthlings never witnessed until Voyager 2 flew near and then beyond Uranus on January 24, 1986. This planet's natural blue-green color is due to the absorption of redder wavelengths in the atmosphere by traces of methane gas. Uranus' diameter is 32,500 miles, a little over four times that of Earth. The hazy blue-green atmosphere probably extends to a depth of around 5,400 miles, where it rests above what is believed to be an icy or liquid mixture (an 'ocean') of water, ammonia, methane, and other volatiles, which in turn surrounds a rocky core perhaps a little smaller than Earth.

  16. 8. Detail showing concrete abutment, showing substructure of bridge, specifically ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Detail showing concrete abutment, showing substructure of bridge, specifically west side of arch and substructure. - Presumpscot Falls Bridge, Spanning Presumptscot River at Allen Avenue extension, 0.75 mile west of U.S. Interstate 95, Falmouth, Cumberland County, ME

  17. 28. MAP SHOWING LOCATION OF ARVFS FACILITY AS BUILT. SHOWS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. MAP SHOWING LOCATION OF ARVFS FACILITY AS BUILT. SHOWS LINCOLN BOULEVARD, BIG LOST RIVER, AND NAVAL REACTORS FACILITY. F.C. TORKELSON DRAWING NUMBER 842-ARVFS-101-2. DATED OCTOBER 12, 1965. INEL INDEX CODE NUMBER: 075 0101 851 151969. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  18. Transient absorption and laser output of YAG : Nd

    NASA Astrophysics Data System (ADS)

    Kvapil, Jiří; Kvapil, Jos; Kubelka, J.; Kubeček, V.

    1981-06-01

    YAG : Nd grown under 98% Ar 2% H2 protective atmosphere free of nitrogen or hydrocarbons showed after UV irradiation broad absorption peaked at ˜1·9×104 cm-1 which disappeared relatively slowly at room temperature. It was more intensive in oxygen treated samples than in those annealed in hydrogsn. Transient absorption suppresses laser output by the increase of absorption at 0·94×104 cm-1 (1064 nm) and, particularly in CW mode, by the anomalous rod deformation. YAG : Nd containing Fe ions (≲2·10-4 wt%) showed no transient absorption.

  19. Absorption heat pumps

    NASA Astrophysics Data System (ADS)

    Huhtinen, M.; Heikkilae, M.; Andersson, R.

    1987-03-01

    The aim of the study was to analyze the technical and economic feasibility of absorption heat pumps in Finland. The work was done as a case study: the technical and economic analyses have been carried out for six different cases, where in each the suitable size and type of the heat pump plant and the auxiliary components and connections were specified. The study also detailed the costs concerning the procurement, installation and test runs of the machinery, as well as the savings in energy costs incurred by the introduction of the plant. Conclusions were drawn of the economic viability of the applications studied. The following cases were analyzed: heat recovery from flue gases and productin of district heat in plants using peat, natural gas, and municipal wastes as a fuel. Heat recovery in the pulp and paper industry for the upgrading of pressure of secondary steam and for the heating of white liquor and combustion and drying the air. Heat recovery in a peat-fulled heat and power plant from flue gases that have been used for the drying of peat. According to the study, the absorption heat pump suits best to the production of district heat, when the heat source is the primary energy is steam produced by the boiler. Included in the flue as condensing is the purification of flue gases. Accordingly, benefit is gained on two levels in thick applications. In heat and power plants the use of absorption heat pumps is less economical, due to the fact that the steam used by the pump reduces the production of electricity, which is rated clearly higher than heat.

  20. Ultraviolet absorption hygrometer

    DOEpatents

    Gersh, Michael E.; Bien, Fritz; Bernstein, Lawrence S.

    1986-01-01

    An ultraviolet absorption hygrometer is provided including a source of pulsed ultraviolet radiation for providing radiation in a first wavelength region where water absorbs significantly and in a second proximate wavelength region where water absorbs weakly. Ultraviolet radiation in the first and second regions which has been transmitted through a sample path of atmosphere is detected. The intensity of the radiation transmitted in each of the first and second regions is compared and from this comparison the amount of water in the sample path is determined.

  1. Ultraviolet absorption hygrometer

    DOEpatents

    Gersh, M.E.; Bien, F.; Bernstein, L.S.

    1986-12-09

    An ultraviolet absorption hygrometer is provided including a source of pulsed ultraviolet radiation for providing radiation in a first wavelength region where water absorbs significantly and in a second proximate wavelength region where water absorbs weakly. Ultraviolet radiation in the first and second regions which has been transmitted through a sample path of atmosphere is detected. The intensity of the radiation transmitted in each of the first and second regions is compared and from this comparison the amount of water in the sample path is determined. 5 figs.

  2. Modular total absorption spectrometer

    NASA Astrophysics Data System (ADS)

    Karny, M.; Rykaczewski, K. P.; Fijałkowska, A.; Rasco, B. C.; Wolińska-Cichocka, M.; Grzywacz, R. K.; Goetz, K. C.; Miller, D.; Zganjar, E. F.

    2016-11-01

    The design and performance of the Modular Total Absorption Spectrometer built and commissioned at the Oak Ridge National Laboratory is presented. The active volume of the detector is approximately one ton of NaI(Tl), which results in very high full γ energy peak efficiency of 71% at 6 MeV and nearly flat efficiency of around 81.5% for low energy γ-rays between 300 keV and 1 MeV. In addition to the high peak efficiency, the modular construction of the detector permits the use of a γ-coincidence technique in data analysis as well as β-delayed neutron observation.

  3. Percutaneous absorption of selenium sulfide

    SciTech Connect

    Farley, J.; Skelly, E.M.; Weber, C.B.

    1986-01-01

    The purpose of this study was to determine selenium levels in the urine of Tinea patients before and after overnight application of a 2.5% selenium sulfide lotion. Selenium was measured by atomic absorption spectroscopy (AAS). Hydride generation and carbon rod atomization were studied. It was concluded from this study that selenium is absorbed through intact skin. Selenium is then excreted, at least partially, in urine, for at least a week following treatment. The data show that absorption and excretion of selenium vary on an individual basis. Selenium levels in urine following a single application of selenium sulfide lotion do not indicate that toxic amounts of selenium are being absorbed. Repeated treatments with SeS/sub 2/ result in selenium concentrations in urine which are significantly higher than normal. Significant matrix effects are observed in the carbon rod atomization of urine samples for selenium determinations, even in the presence of a matrix modifier such as nickel. The method of standard additions is required to obtain accurate results in the direct determination of selenium in urine by carbon rod AAS.

  4. Airborne spectrophotometry of P/Halley from 16 to 30 microns

    NASA Technical Reports Server (NTRS)

    Herter, T.; Gull, G. E.; Campins, H.

    1986-01-01

    Comet Halley was observed in the 16 to 30 micron region using the Cornell University 7-channel spectrometer (resolution = 0.02) on board the Kuiper Airborne Observatory on 1985 Dec. 14.2. A 30-arcsec aperture (FWHM) was used. Measurements centered on the nuclear condensation micron indicate that if present, the 20 micron silicate feature is very weak, and that a relatively narrow strong feature centered at 28.4 microns possibly exists. However, this feature may be an artifact of incomplete correction for telluric water vapor absorption.

  5. [Alleviated affect of exogenous CaCl2 on the growth, antioxidative enzyme activities and cadmium absorption efficiency of Wedelia trilobata hairy roots under cadmium stress].

    PubMed

    Shi, Heping; Wang, Yunling; Tsang, PoKeung Eric; Chan, LeeWah Andrew

    2012-06-01

    In order to study the physiological mechanism of exogenous calcium on the toxicity of heavy metal cadmium (Cd) to Wedelia trilobata hairy roots, the effects of Cd alone, and in combination with different concentrations of Ca on growth, contents of soluble protein and malondialdehyde (MDA), activities of superoxide dismutase (SOD) and peroxidase (POD), Cd2+ absorption in W. trilobata hairy roots were investigated. Cd concentrations lower than 50 micromol/L enhanced the growth of hairy roots, while concentrations higher than 100 micromol/L inhibited growth, making the branched roots short and small, and also turning the root tips brown, even black. In comparison with the control (0 micromol/L Cd), the soluble protein content in hairy roots was found to increase when cultured with 10-50 micromol/L Cd, and decrease when exposed to a cadmium concentration higher than 100 micromol/L Cd. In addition, the activities of POD and SOD activity and MDA content were significantly higher than the control. Compared to the control (hairy roots cultured without 10-30 mmol/L Ca), 100 micromol/L Cd or 300 micromol/L Cd in combination with 10-30 mmol/L Ca resulted in increased growth, causing the main root and secondary roots thicker and also an increase in soluble protein content. On the contrary, MDA content and POD and SOD activities decreased. Quantitative analysis by Atomic Absorption Spectrophotometry showed that W. trilobata hairy roots can absorb and adsorb heavy metal Cd in the ionic form of Cd2+. The maximum content of Cd2+ absorbed by the hairy roots was obtained with a concentration 100 micromol/L Cd2+ while that of Cd2+ adsorbed by hairy roots was achieved with a concentration of 300 micromol/L Cd2+. The exogenous addition of 10-30 mmol/L Ca2+ was found to reduce the absorption, adsorption of Cd2+ and the toxicity of Cd significantly. This reduction in toxicity was caused by the reduction in the absorption of Cd and decreasing the lipid peroxidation through regulating the

  6. What Do Blood Tests Show?

    MedlinePlus

    ... shows the ranges for blood glucose levels after 8 to 12 hours of fasting (not eating). It shows the normal range and the abnormal ranges that are a sign of prediabetes or diabetes. Plasma Glucose Results (mg/dL)* Diagnosis 70 to 99 ...

  7. Water-related absorption in fibrous diamonds

    NASA Astrophysics Data System (ADS)

    Zedgenizov, D. A.; Shiryaev, A. A.; Kagi, H.; Navon, O.

    2003-04-01

    Cubic and coated diamonds from several localities (Brasil, Canada, Yakutia) were investigated using spectroscopic techniques. Special emphasis was put on investigation of water-related features of transmission Infra-red and Raman spectra. Presence of molecular water is inferred from broad absorption bands in IR at 3420 and 1640 cm-1. These bands were observed in many of the investigated samples. It is likely that molecular water is present in microinclusions in liquid state, since no clear indications of solid H_2O (ice VI-VII, Kagi et al., 2000) were found. Comparison of absorption by HOH and OH vibrations shows that diamonds can be separated into two principal groups: those containing liquid water (direct proportionality of OH and HOH absorption) and those with stronger absorption by OH group. Fraction of diamonds in every group depends on their provenance. There might be positive correlation between internal pressure in microinclusions (determined using quartz barometer, Navon et al., 1988) and affiliation with diamonds containing liquid water. In many cases absorption by HOH vibration is considerably lower than absorption by hydroxyl (OH) group. This may be explained if OH groups are partially present in mineral and/or melt inclusions. This hypothesis is supported by following fact: in diamonds with strong absorption by silicates and other minerals shape and position of the OH band differs from that in diamonds with low absorption by minerals. Moreover, in Raman spectra of individual inclusions sometimes the broad band at 3100 cm-1 is observed. This band is OH-related. In some samples water distribution is not homogeneous. Central part of the diamond usually contains more water than outer parts, but this is not a general rule for all the samples. Water absorption usually correlated with absorption of other components (carbonates, silicates and others). At that fibrous diamonds with relatively high content of silicates are characterized by molecular water. OH

  8. Calculation of laser absorption by metal powders in additive manufacturing.

    PubMed

    Boley, C D; Khairallah, S A; Rubenchik, A M

    2015-03-20

    We have calculated the absorption of laser light by a powder of metal spheres, typical of the powder employed in laser powder-bed fusion additive manufacturing. Using ray-trace simulations, we show that the absorption is significantly larger than its value for normal incidence on a flat surface, due to multiple scattering. We investigate the dependence of absorption on powder content (material, size distribution, and geometry) and on beam size.

  9. Determination of specific activity of iron-55 by spectrophotometry and liquid scintillation counting with bathophenanthroline complex

    SciTech Connect

    Yonezawa, C.; Hoshi, M.; Tachikawa, E.

    1985-12-01

    A method for determining the macroscopic amount of iron and its radioactivity (/sup 55/Fe) in radioactive corrosion products was established with a single chemical procedure. The iron was first extracted into a liquid scintillator (2,5-diphenyloxazole-xylene) as an ion associate of iron bathophenanthroline (BPT) complex and perchlorate at pH 3-8, followed by measurement of its radioactivity by a liquid scintillation counter and its absorbance by a spectrophotometer. The absorption maximum and molar absorptivity (epsilon) of the complex were 535 nm and 22,000, respectively. The system conforms to Beer's law at concentrations of up to 30 ..mu..g of iron in 10 mL of organic phase. The counting efficiency of the extracted /sup 55/Fe was found to be 60%. Although /sup 60/Co is extracted into the PPO-xylene together with /sup 5/)2%Fe, it is separated from /sup 55/Fe by back extraction with 0.005 M ethylenediaminetetraacetic acid (pH 6.0) into the aqueous phase. The effects of other foreign elements and radionuclides were also examined. The proposed method was successfully applied to analysis of radioactive corrosion products. 21 references, 6 figures, 3 tables.

  10. Spectrophotometry of pluto-charon mutual events: individual spectra of pluto and charon.

    PubMed

    Sawyer, S R; Barker, E S; Cochran, A L; Cochran, W D

    1987-12-11

    Time-resolved spectra of the 3 March and 4 April 1987 mutual events of Pluto and its satellite Charon were obtained with spectral coverage from 5,500 to 10,000 angstroms with 25 angstrom spectral resolution. Since both events were total occultations of Charon by Pluto, spectra were obtained of the anti-Charon-facing hemisphere of Pluto, with no contribution from Charon during totality. On 4 April, a combined spectrum of Pluto and Charon immediately before first contact was also obtained. The spectrum of the Pluto-facing hemisphere of Charon was extracted by differencing the pre-event and totality spectra. The spectra were reduced to reflectances by ratioing them to spectra of solar analog stars. Charon has a featureless reflectance spectrum, with no evidence of methane absorption. Charon's reflectance appears neutral in color and corresponds to a geometric albedo of approximately 0.37 at 6000 angstroms. The Pluto reflectance spectrum displays methane absorption bands at 7300, 7900, 8400, 8600, and 8900 angstroms and is red in color, with a geometric albedo of approximately 0.56 at 6000 angstroms. The signal-to-noise ratios of the eclipse spectra were not high enough to unambiguously identify the weaker methane band at 6200 angstroms.

  11. Satellite Movie Shows Erika Dissipate

    NASA Video Gallery

    This animation of visible and infrared imagery from NOAA's GOES-West satellite from Aug. 27 to 29 shows Tropical Storm Erika move through the Eastern Caribbean Sea and dissipate near eastern Cuba. ...

  12. An atomic-absorption method for the determination of gold in large samples of geologic materials

    USGS Publications Warehouse

    VanSickle, Gordon H.; Lakin, Hubert William

    1968-01-01

    A laboratory method for the determination of gold in large (100-gram) samples has been developed for use in the study of the gold content of placer deposits and of trace amounts of gold in other geologic materials. In this method the sample is digested with bromine and ethyl ether, the gold is extracted into methyl isobutyl ketone, and the determination is made by atomicabsorption spectrophotometry. The lower limit of detection is 0.005 part per million in the sample. The few data obtained so far by this method agree favorably with those obtained by assay and by other atomic-absorption methods. About 25 determinations can be made per man-day.

  13. Stability properties of wines by absorption spectra

    NASA Astrophysics Data System (ADS)

    Larena, A.; Vega, J.

    1986-03-01

    The temporal evolution of absorption spectra (370-700 nm) of different spanish wines has been studied by us under the influence of air presence, and the light exposition. In particular, we have exposed the wines to a magenta light. Nevertheless, the color coordinates of wine show a little relative variation (0.1-1 %)

  14. Quantum-enhanced absorption refrigerators

    NASA Astrophysics Data System (ADS)

    Correa, Luis A.; Palao, José P.; Alonso, Daniel; Adesso, Gerardo

    2014-02-01

    Thermodynamics is a branch of science blessed by an unparalleled combination of generality of scope and formal simplicity. Based on few natural assumptions together with the four laws, it sets the boundaries between possible and impossible in macroscopic aggregates of matter. This triggered groundbreaking achievements in physics, chemistry and engineering over the last two centuries. Close analogues of those fundamental laws are now being established at the level of individual quantum systems, thus placing limits on the operation of quantum-mechanical devices. Here we study quantum absorption refrigerators, which are driven by heat rather than external work. We establish thermodynamic performance bounds for these machines and investigate their quantum origin. We also show how those bounds may be pushed beyond what is classically achievable, by suitably tailoring the environmental fluctuations via quantum reservoir engineering techniques. Such superefficient quantum-enhanced cooling realises a promising step towards the technological exploitation of autonomous quantum refrigerators.

  15. Transient simulation of absorption machines

    NASA Astrophysics Data System (ADS)

    Anand, D. K.; Allen, R. W.; Kumar, B.

    A model for a water-cooled Lithium-Bromide/water absorption chiller is presented. Its transient response both during the start-up phase and during the shut-off period is predicted. The simulation model incorporates such influencing factors as the thermodynamic properties of the working fluid, the absorbent, the heat-transfer configuration of different components of the chiller and related physical data. The time constants of different components are controlled by a set of key parameters that have been identified. The results show a variable but at times significant amount of time delay before the chiller capacity gets close to its steady-state value. The model is intended to provide an insight into the mechanism of build-up to steady-state performance. By recognizing the significant factors contributing to transient degradation, steps can be taken to reduce such degradation.

  16. Quantum-enhanced absorption refrigerators.

    PubMed

    Correa, Luis A; Palao, José P; Alonso, Daniel; Adesso, Gerardo

    2014-01-01

    Thermodynamics is a branch of science blessed by an unparalleled combination of generality of scope and formal simplicity. Based on few natural assumptions together with the four laws, it sets the boundaries between possible and impossible in macroscopic aggregates of matter. This triggered groundbreaking achievements in physics, chemistry and engineering over the last two centuries. Close analogues of those fundamental laws are now being established at the level of individual quantum systems, thus placing limits on the operation of quantum-mechanical devices. Here we study quantum absorption refrigerators, which are driven by heat rather than external work. We establish thermodynamic performance bounds for these machines and investigate their quantum origin. We also show how those bounds may be pushed beyond what is classically achievable, by suitably tailoring the environmental fluctuations via quantum reservoir engineering techniques. Such superefficient quantum-enhanced cooling realises a promising step towards the technological exploitation of autonomous quantum refrigerators. PMID:24492860

  17. Assessment of cosmetic ingredients in the in vitro reconstructed human epidermis test method EpiSkin™ using HPLC/UPLC-spectrophotometry in the MTT-reduction assay.

    PubMed

    Alépée, N; Hibatallah, J; Klaric, M; Mewes, K R; Pfannenbecker, U; McNamee, P

    2016-06-01

    Cosmetics Europe recently established HPLC/UPLC-spectrophotometry as a suitable alternative endpoint detection system for measurement of formazan in the MTT-reduction assay of reconstructed human tissue test methods irrespective of the test system involved. This addressed a known limitation for such test methods that use optical density for measurement of formazan and may be incompatible for evaluation of strong MTT reducer and/or coloured chemicals. To build on the original project, Cosmetics Europe has undertaken a second study that focuses on evaluation of chemicals with functionalities relevant to cosmetic products. Such chemicals were primarily identified from the Scientific Committee on Consumer Safety (SCCS) 2010 memorandum (addendum) on the in vitro test EpiSkin™ for skin irritation testing. Fifty test items were evaluated in which both standard photometry and HPLC/UPLC-spectrophotometry were used for endpoint detection. The results obtained in this study: 1) provide further support for Within Laboratory Reproducibility of HPLC-UPLC-spectrophotometry for measurement of formazan; 2) demonstrate, through use a case study with Basazol C Blue pr. 8056, that HPLC/UPLC-spectrophotometry enables determination of an in vitro classification even when this is not possible using standard photometry and 3) addresses the question raised by SCCS in their 2010 memorandum (addendum) to consider an endpoint detection system not involving optical density quantification in in vitro reconstructed human epidermis skin irritation test methods. PMID:26891813

  18. Assessment of cosmetic ingredients in the in vitro reconstructed human epidermis test method EpiSkin™ using HPLC/UPLC-spectrophotometry in the MTT-reduction assay.

    PubMed

    Alépée, N; Hibatallah, J; Klaric, M; Mewes, K R; Pfannenbecker, U; McNamee, P

    2016-06-01

    Cosmetics Europe recently established HPLC/UPLC-spectrophotometry as a suitable alternative endpoint detection system for measurement of formazan in the MTT-reduction assay of reconstructed human tissue test methods irrespective of the test system involved. This addressed a known limitation for such test methods that use optical density for measurement of formazan and may be incompatible for evaluation of strong MTT reducer and/or coloured chemicals. To build on the original project, Cosmetics Europe has undertaken a second study that focuses on evaluation of chemicals with functionalities relevant to cosmetic products. Such chemicals were primarily identified from the Scientific Committee on Consumer Safety (SCCS) 2010 memorandum (addendum) on the in vitro test EpiSkin™ for skin irritation testing. Fifty test items were evaluated in which both standard photometry and HPLC/UPLC-spectrophotometry were used for endpoint detection. The results obtained in this study: 1) provide further support for Within Laboratory Reproducibility of HPLC-UPLC-spectrophotometry for measurement of formazan; 2) demonstrate, through use a case study with Basazol C Blue pr. 8056, that HPLC/UPLC-spectrophotometry enables determination of an in vitro classification even when this is not possible using standard photometry and 3) addresses the question raised by SCCS in their 2010 memorandum (addendum) to consider an endpoint detection system not involving optical density quantification in in vitro reconstructed human epidermis skin irritation test methods.

  19. Monitoring Emergent Absorption Troughs in Quasars

    NASA Astrophysics Data System (ADS)

    Hall, Patrick; Rodriguez Hidalgo, Paola; Brandt, W. Niel; Rogerson, Jesse; Filiz Ak, Nur; Chajet, Laura

    2014-02-01

    Outflows from luminous AGN are important ingredients in galaxy formation. These outflows manifest as broad absorption line (BAL) troughs in quasar spectra. Trough variability can be used to constrain the physical parameters of these absorbing structures through comparison to models and simulations of accretion disk winds. Monitoring appearing/disappearing BAL troughs can constrain the distribution of BAL trough lifetimes along our line of sight. By comparing spectra from the SDSS Data Release (DR) 7 and DR 9, we identified 68 quasars in whose spectra new absorption troughs have appeared over 300-1200 restframe days, including one trough outflowing at v=60,000 km/s. We propose to complete our third-epoch GMOS spectroscopy of the brightest of those quasars (48 in 2013AB and 9 proposed here) to measure the absorption strength in newly appeared troughs <=365 restframe days after their previous measurement. Preliminary 2013AB results indicate that troughs are not on average still strengthening between SDSS and Gemini epochs; we therefore propose observations of 40 targets to probe shorter rest-frame time separations. We also target 8 objects showing simultaneous absorption variations in multiple ionization states, to help develop methods to distinguish absorption variations from cloud motion vs. those from ionization changes within clouds.

  20. Airborne spectrophotometry of Eta Carinae from 4.5 to 7.5 microns and a model for source morphology

    NASA Technical Reports Server (NTRS)

    Russell, Ray W.; Lynch, David K.; Hackwell, John A.; Rudy, Richard J.; Rossano, George S.; Castelaz, M. W.

    1987-01-01

    Spectrophotometric observations of Eta Car between 4.5 and 7.5 microns show a featureless thermal-like spectrum with no fine-structure lines or broad emission or absorption features. The color temperature of the spectrum is approximately 375 K. High spatial resolution maps at 3.5, 4.8, and 10 microns obtained from the ground are used to discuss the dust distribution and temperature structure, and to present a model for general source morphology. The upper limit to the brightness of the forbidden Ar II fine-structure emission line at 6.98 microns is less than 7 x 10 to the -16th W/sq cm, which still allows for a significant overabundance of argon and is consistent with the evolved nature of the source.

  1. National Orange Show Photovoltaic Demonstration

    SciTech Connect

    Dan Jimenez Sheri Raborn, CPA; Tom Baker

    2008-03-31

    National Orange Show Photovoltaic Demonstration created a 400KW Photovoltaic self-generation plant at the National Orange Show Events Center (NOS). The NOS owns a 120-acre state fairground where it operates an events center and produces an annual citrus fair known as the Orange Show. The NOS governing board wanted to employ cost-saving programs for annual energy expenses. It is hoped the Photovoltaic program will result in overall savings for the NOS, help reduce the State's energy demands as relating to electrical power consumption, improve quality of life within the affected grid area as well as increase the energy efficiency of buildings at our venue. In addition, the potential to reduce operational expenses would have a tremendous effect on the ability of the NOS to service its community.

  2. Super-Resonant Intracavity Coherent Absorption

    PubMed Central

    Malara, P.; Campanella, C. E.; Giorgini, A.; Avino, S.; De Natale, P.; Gagliardi, G.

    2016-01-01

    The capability of optical resonators to extend the effective radiation-matter interaction length originates from a multipass effect, hence is intrinsically limited by the resonator’s quality factor. Here, we show that this constraint can be overcome by combining the concepts of resonant interaction and coherent perfect absorption (CPA). We demonstrate and investigate super-resonant coherent absorption in a coupled Fabry-Perot (FP)/ring cavity structure. At the FP resonant wavelengths, the described phenomenon gives rise to split modes with a nearly-transparent peak and a peak whose transmission is exceptionally sensitive to the intracavity loss. For small losses, the effective interaction pathlength of these modes is proportional respectively to the ratio and the product of the individual finesse coefficients of the two resonators. The results presented extend the conventional definition of resonant absorption and point to a way of circumventing the technological limitations of ultrahigh-quality resonators in spectroscopy and optical sensing schemes. PMID:27364475

  3. Super-Resonant Intracavity Coherent Absorption.

    PubMed

    Malara, P; Campanella, C E; Giorgini, A; Avino, S; De Natale, P; Gagliardi, G

    2016-01-01

    The capability of optical resonators to extend the effective radiation-matter interaction length originates from a multipass effect, hence is intrinsically limited by the resonator's quality factor. Here, we show that this constraint can be overcome by combining the concepts of resonant interaction and coherent perfect absorption (CPA). We demonstrate and investigate super-resonant coherent absorption in a coupled Fabry-Perot (FP)/ring cavity structure. At the FP resonant wavelengths, the described phenomenon gives rise to split modes with a nearly-transparent peak and a peak whose transmission is exceptionally sensitive to the intracavity loss. For small losses, the effective interaction pathlength of these modes is proportional respectively to the ratio and the product of the individual finesse coefficients of the two resonators. The results presented extend the conventional definition of resonant absorption and point to a way of circumventing the technological limitations of ultrahigh-quality resonators in spectroscopy and optical sensing schemes. PMID:27364475

  4. Super-Resonant Intracavity Coherent Absorption

    NASA Astrophysics Data System (ADS)

    Malara, P.; Campanella, C. E.; Giorgini, A.; Avino, S.; de Natale, P.; Gagliardi, G.

    2016-07-01

    The capability of optical resonators to extend the effective radiation-matter interaction length originates from a multipass effect, hence is intrinsically limited by the resonator’s quality factor. Here, we show that this constraint can be overcome by combining the concepts of resonant interaction and coherent perfect absorption (CPA). We demonstrate and investigate super-resonant coherent absorption in a coupled Fabry-Perot (FP)/ring cavity structure. At the FP resonant wavelengths, the described phenomenon gives rise to split modes with a nearly-transparent peak and a peak whose transmission is exceptionally sensitive to the intracavity loss. For small losses, the effective interaction pathlength of these modes is proportional respectively to the ratio and the product of the individual finesse coefficients of the two resonators. The results presented extend the conventional definition of resonant absorption and point to a way of circumventing the technological limitations of ultrahigh-quality resonators in spectroscopy and optical sensing schemes.

  5. Nanofibrous membrane-based absorption refrigeration system

    SciTech Connect

    Isfahani, RN; Sampath, K; Moghaddam, S

    2013-12-01

    This paper presents a study on the efficacy of highly porous nanofibrous membranes for application in membrane-based absorbers and desorbers. Permeability studies showed that membranes with a pore size greater than about one micron have a sufficient permeability for application in the absorber heat exchanger. Membranes with smaller pores were found to be adequate for the desorber heat exchanger. The membranes were implemented in experimental membrane-based absorber and desorber modules and successfully tested. Parametric studies were conducted on both absorber and desorber processes. Studies on the absorption process were focused on the effects of water vapor pressure, cooling water temperature, and the solution velocity on the absorption rate. Desorption studies were conducted on the effects of wall temperature, vapor and solution pressures, and the solution velocity on the desorption rate. Significantly higher absorption and desorption rates than in the falling film absorbers and desorbers were achieved. Published by Elsevier Ltd.

  6. Combination of fluorescence imaging and local spectrophotometry in fluorescence diagnostics of early cancer of larynx and bronchi

    SciTech Connect

    Sokolov, Vladimir V; Filonenko, E V; Telegina, L V; Boulgakova, N N; Smirnov, V V

    2002-11-30

    The results of comparative studies of autofluorescence and 5-ALA-induced fluorescence of protoporphyrin IX, used in the diagnostics of early cancer of larynx and bronchi, are presented. The autofluorescence and 5-ALA-induced fluorescence images of larynx and bronchial tissues are analysed during the endoscopic study. The method of local spectrophotometry is used to verify findings obtained from fluorescence images. It is shown that such a combined approach can be efficiently used to improve the diagnostics of precancer and early cancer, to detect a primary multiple tumours, as well as for the diagnostics of a residual tumour or an early recurrence after the endoscopic, surgery or X-ray treatment. The developed approach allows one to minimise the number of false-positive results and to reduce the number of biopsies, which are commonly used in the white-light bronchoscopy search for occult cancerous loci. (laser biology and medicine)

  7. The measurement of meat pigments by fibre-optic reflectance spectrophotometry using the Kubelka-Munk equation.

    PubMed

    Osawa, M

    1995-01-01

    A reflectance spectrophotometry system with an adhesive pad type fibreoptic probe was developed to measure a wide range of absorbance. The performance of the instrument was evaluated by undertaking in vitro measurements of the reflectance spectra of metmyoglobin solution and meat pastes containing known amounts of oxy-, deoxy- and metmyoglobin. The absorbance of metmyoglobin solution in the range of 0-4 mg/dl as successfully distinguised, but at the upper range of 4 mg/ml the reflectance results were not in proportion to the concentration. All absorbances at 525 nm for meat pastes were also not in proportion to the concentration. These non-linearities were considered to be a result of back-scattering. Therefore, the K/S value of the Kubelka-Munk equation was applied in an effort the refine the fibre optic reflectance method. Positive correlations between the myoglobin concentration and the K/S values obtained from spectra of meat pastes were found.

  8. The application of spectrophotometry in the investigation of amniotic fluid by amnioscopy. part I. development of the technique.

    PubMed

    Järvinen, P A; Ylöstalo, P; Hartikainen, A L; Rönnberg, L

    1975-10-01

    A method for the incorporation of spectrophotometry to amnioscopy for the colourmetric estimation of amniotic fluid is presented. The spectrum of light reflected from the object under examination was measured using narrow-band interference filters, and a siliceous PIN light diode as the detector. A graphical representation of the spectrum was obtained using an automatic recorder. The preliminary measurements were performed using papers of various colours, clear amniotic fluid and green fluid as well as two patients in late pregnancy who required amnioscopic investigation. Measurements have shown that the apparatus can reliably distinguish different colours from each other and the authors consider that the apparatus may be used in connection with amnioscopy in order to estimate the colour of the amniotic fluid. The possible future use and development of such a technique is discussed. PMID:1210479

  9. Arches showing UV flaring activity

    NASA Technical Reports Server (NTRS)

    Fontenla, J. M.

    1988-01-01

    The UVSP data obtained in the previous maximum activity cycle show the frequent appearance of flaring events in the UV. In many cases these flaring events are characterized by at least two footpoints which show compact impulsive non-simultaneous brightenings and a fainter but clearly observed arch developes between the footpoints. These arches and footpoints are observed in line corresponding to different temperatures, as Lyman alpha, N V, and C IV, and when observed above the limb display large Doppler shifts at some stages. The size of the arches can be larger than 20 arcsec.

  10. Analyzing Water's Optical Absorption

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A cooperative agreement between World Precision Instruments (WPI), Inc., and Stennis Space Center has led the UltraPath(TM) device, which provides a more efficient method for analyzing the optical absorption of water samples at sea. UltraPath is a unique, high-performance absorbance spectrophotometer with user-selectable light path lengths. It is an ideal tool for any study requiring precise and highly sensitive spectroscopic determination of analytes, either in the laboratory or the field. As a low-cost, rugged, and portable system capable of high- sensitivity measurements in widely divergent waters, UltraPath will help scientists examine the role that coastal ocean environments play in the global carbon cycle. UltraPath(TM) is a trademark of World Precision Instruments, Inc. LWCC(TM) is a trademark of World Precision Instruments, Inc.

  11. Measuring absorption coefficient of scattering liquids using a tube inside an integrating sphere.

    PubMed

    Villanueva, Yolanda; Veenstra, Colin; Steenbergen, Wiendelt

    2016-04-10

    A method for measuring the absorption coefficient μa of absorbing and scattering liquid samples is presented. The sample is injected into a small transparent tube mounted through an integrating sphere. Two models for determining the absorption coefficient using the relative optical output signal are described and validated using aqueous ink absorbers of 0.5 vol.% (0.3  mm-1a<1.55  mm-1) and 1.0 vol.% (1.0  mm-1a<4.0  mm-1) concentrations with 1 vol.% (μs'≈1.4  mm-1) and 10 vol.% (μs'≈14  mm-1) Intralipid dilutions. The low concentrations give μa and μs values, which are comparable with those of biological tissues. One model assumes a uniform light distribution within the sample, which is valid for low absorption. Another model considers light attenuation that obeys Lambert-Beer's law, which may be used for relatively high absorption. Measurements with low and high scattering samples are done for the wavelength range of 400-900 nm. Measured spectra of purely absorbing samples are within 15% agreement with measurements using standard transmission spectrophotometry. For 0.5 vol.% ink absorbers and at wavelengths below 700 nm, measured μa values are higher for samples with low scattering and lower for those with high scattering. At wavelengths above 700 nm, measured μa values do not vary significantly with amount of scattering. For 1.0 vol.% ink absorbers, measured spectra do not change with low scattering. These results indicate that the method can be used for measuring absorption spectra of scattering liquid samples with optical properties similar to biological absorbers, particularly at wavelengths above 700 nm, which is difficult to accomplish with standard transmission spectrophotometry.

  12. Benefit of cerebrospinal fluid spectrophotometry in the assessment of CT scan negative suspected subarachnoid haemorrhage: a diagnostic accuracy study.

    PubMed

    Hann, Angus; Chu, Kevin; Greenslade, Jaimi; Williams, Julian; Brown, Anthony

    2015-01-01

    This study aimed to determine if performing cerebrospinal fluid spectrophotometry in addition to visual inspection detects more ruptured cerebral aneurysms than performing cerebrospinal fluid visual inspection alone in patients with a normal head CT scan but suspected of suffering an aneurysmal subarachnoid haemorrhage (SAH). We performed a single-centre retrospective study of patients presenting to the emergency department of a tertiary hospital who underwent both head CT scan and lumbar puncture to exclude SAH. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of an approach utilising both spectrophotometry and visual inspection (combined approach) was compared to visual inspection alone. A total of 409 patients (mean age 37.8 years, 56.2% female) were recruited and six (1.5%) had a cerebral aneurysm on angiography. The sensitivity of visual inspection was 50% (95% confidence interval [CI]: 12.4-82.6%), specificity was 99% (95% CI: 97.5-99.7%), PPV was 42.9% (95% CI: 10.4-81.3%) and NPV was 99.2% (95% CI: 97.8-99.8%). The combined approach had a sensitivity of 100% (95% CI: 54.1-100%), specificity of 79.7% (95% CI: 75.4-83.5%), PPV of 6.8% (95% CI: 2.6-14.3%) and a NPV of 100% (95% CI: 98.8-100%). The sensitivity of the combined approach was not significantly different to that of visual inspection alone (p=0.25). Visual inspection had a significantly higher specificity than the combined approach (p<0.01). The combined approach detected more cases of aneurysmal SAH than visual inspection alone, however the difference in sensitivity was not statistically significant. Visual xanthochromia should prompt angiography because of a superior specificity and PPV. Due to its reduced sensitivity, caution should be applied when using only visual inspection of the supernatant.

  13. Create a Polarized Light Show.

    ERIC Educational Resources Information Center

    Conrad, William H.

    1992-01-01

    Presents a lesson that introduces students to polarized light using a problem-solving approach. After illustrating the concept using a slinky and poster board with a vertical slot, students solve the problem of creating a polarized light show using Polya's problem-solving methods. (MDH)

  14. Pembrolizumab Shows Promise for NSCLC.

    PubMed

    2015-06-01

    Data from the KEYNOTE-001 trial show that pembrolizumab improves clinical outcomes for patients with advanced non-small cell lung cancer, and is well tolerated. PD-L1 expression in at least 50% of tumor cells correlated with improved efficacy.

  15. Spectrophotometry /0.33 to 1.07 microns/ of 433 Eros and compositional implications

    NASA Technical Reports Server (NTRS)

    Pieters, C.; Gaffey, M. J.; Chapman, C. R.; Mccord, T. B.

    1976-01-01

    The spectral reflectance (0.33-1.07 micrometers) for the asteroid 433 Eros was determined as a function of rotational phase during January 28-30, and February 15, 1975. Interpretation of absorption features suggests Eros is composed of an undifferentiated assemblage of moderate to high temperature minerals (iron, pyroxene, and olivine, but no carbon). H-type ordinary chondrites are such assemblages, but it would be premature to conclude that Eros is like an H chondrite meteorite in composition until a better understanding is reached of possible physical differences between laboratory powders and asteroid regoliths for metal-bearing assemblages. There are no large-scale major compositional variations on the different sides of Eros.

  16. Spectrophotometry in vivo, a technique for local and direct enzymatic assays: application to brain acetylcholinesterase.

    PubMed Central

    Testylier, G; Gourmelon, P

    1987-01-01

    In vivo enzymology is not widely studied due to the lack of a well-adapted technology. We have developed a system that allows local and long-term spectrophotometric assays in brain tissue of live animals. It utilizes a miniaturized optical probe consisting of a multibarrel micropipette for reagent injections and optical fibers for light absorption measurements. We have applied this system to the colorimetric determination of brain acetylcholinesterase activity in rats. The reproducibility of the assay was demonstrated by repetitive assays over 24 hr, its specificity was established through the use of a highly specific organophosphorus inhibitor, and the activities measured in different brain areas agreed with the known distribution of acetylcholinesterase. No electroencephalographic abnormalities and no change in vigilance level were observed in the experimental animals. This methodology should prove to be useful for the colorimetric measurement of different enzymes or metabolites in various organs. PMID:3479782

  17. [Rate of controlled-release urea pervasion through membrane determined by ultraviolet spectrophotometry].

    PubMed

    Zuo, Xiu-jin; Wang, Zhen-xin; Dai, Xiao-min; Zhou, Yi; Ma, Xiao-jun

    2006-06-01

    Application of controlled-release nitrogenous fertilizers can improve the efficiency of fertilizers and reduce the environmental pollution. Controlled-release urea (coated urea) is one of the controlled-release nitrogenous fertilizers developed quickly in the recent years. The rate of controlled-release urea pervasion through membrane is the most important index of the capacity of controlled release. There is a maximum absorption at lambda=426 nm with complex in acidic solution, using p-dimethylaminozenzaldehyde as color reagent, and the absorbance exhibits a linear reponses to the urea concentration over the range of 7.5-210 microg x mL(-1). The method for determining the rate of controlled-release urea pervasion through membrane was realized through determining the content of urea in the liquor, the recovery efficiency of the method is 96.1%-103.9%. PMID:16961255

  18. [Rate of controlled-release urea pervasion through membrane determined by ultraviolet spectrophotometry].

    PubMed

    Zuo, Xiu-jin; Wang, Zhen-xin; Dai, Xiao-min; Zhou, Yi; Ma, Xiao-jun

    2006-06-01

    Application of controlled-release nitrogenous fertilizers can improve the efficiency of fertilizers and reduce the environmental pollution. Controlled-release urea (coated urea) is one of the controlled-release nitrogenous fertilizers developed quickly in the recent years. The rate of controlled-release urea pervasion through membrane is the most important index of the capacity of controlled release. There is a maximum absorption at lambda=426 nm with complex in acidic solution, using p-dimethylaminozenzaldehyde as color reagent, and the absorbance exhibits a linear reponses to the urea concentration over the range of 7.5-210 microg x mL(-1). The method for determining the rate of controlled-release urea pervasion through membrane was realized through determining the content of urea in the liquor, the recovery efficiency of the method is 96.1%-103.9%.

  19. Percutaneous absorption in preterm infants.

    PubMed

    West, D P; Halket, J M; Harvey, D R; Hadgraft, J; Solomon, L M; Harper, J I

    1987-11-01

    The skin of preterm infants varies considerably in its level of maturity. To understand skin absorption in premature infants better, we report a technique for the assessment of percutaneous absorption at various gestational and postnatal ages using stable, isotope-labeled (13C6) benzoic acid. Our results indicate that in the preterm infant, this method detects enhanced skin absorption in the first postnatal days, which declines over three weeks to that expected of a full-term infant. This approach also indicates an inverse relationship between gestational age and skin absorption, as well as postnatal age and skin absorption. The reported technique is a safe and noninvasive method using a model skin penetrant for the study of percutaneous absorption in preterm infants from which basic data may be derived to add to our understanding of skin barrier function. PMID:3422856

  20. Magic Carpet Shows Its Colors

    NASA Technical Reports Server (NTRS)

    2004-01-01

    The upper left image in this display is from the panoramic camera on the Mars Exploration Rover Spirit, showing the 'Magic Carpet' region near the rover at Gusev Crater, Mars, on Sol 7, the seventh martian day of its journey (Jan. 10, 2004). The lower image, also from the panoramic camera, is a monochrome (single filter) image of a rock in the 'Magic Carpet' area. Note that colored portions of the rock correlate with extracted spectra shown in the plot to the side. Four different types of materials are shown: the rock itself, the soil in front of the rock, some brighter soil on top of the rock, and some dust that has collected in small recesses on the rock face ('spots'). Each color on the spectra matches a line on the graph, showing how the panoramic camera's different colored filters are used to broadly assess the varying mineral compositions of martian rocks and soils.

  1. X-ray Absorption Spectroscopy

    SciTech Connect

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  2. 14 CFR 23.723 - Shock absorption tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Shock absorption tests. 23.723 Section 23.723 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT... showing its reserve energy absorption capacity, simulating a descent velocity of 1.2 times the...

  3. ShowMe3D

    SciTech Connect

    Sinclair, Michael B

    2012-01-05

    ShowMe3D is a data visualization graphical user interface specifically designed for use with hyperspectral image obtained from the Hyperspectral Confocal Microscope. The program allows the user to select and display any single image from a three dimensional hyperspectral image stack. By moving a slider control, the user can easily move between images of the stack. The user can zoom into any region of the image. The user can select any pixel or region from the displayed image and display the fluorescence spectrum associated with that pixel or region. The user can define up to 3 spectral filters to apply to the hyperspectral image and view the image as it would appear from a filter-based confocal microscope. The user can also obtain statistics such as intensity average and variance from selected regions.

  4. "Show me" bioethics and politics.

    PubMed

    Christopher, Myra J

    2007-10-01

    Missouri, the "Show Me State," has become the epicenter of several important national public policy debates, including abortion rights, the right to choose and refuse medical treatment, and, most recently, early stem cell research. In this environment, the Center for Practical Bioethics (formerly, Midwest Bioethics Center) emerged and grew. The Center's role in these "cultural wars" is not to advocate for a particular position but to provide well researched and objective information, perspective, and advocacy for the ethical justification of policy positions; and to serve as a neutral convener and provider of a public forum for discussion. In this article, the Center's work on early stem cell research is a case study through which to argue that not only the Center, but also the field of bioethics has a critical role in the politics of public health policy.

  5. ShowMe3D

    2012-01-05

    ShowMe3D is a data visualization graphical user interface specifically designed for use with hyperspectral image obtained from the Hyperspectral Confocal Microscope. The program allows the user to select and display any single image from a three dimensional hyperspectral image stack. By moving a slider control, the user can easily move between images of the stack. The user can zoom into any region of the image. The user can select any pixel or region from themore » displayed image and display the fluorescence spectrum associated with that pixel or region. The user can define up to 3 spectral filters to apply to the hyperspectral image and view the image as it would appear from a filter-based confocal microscope. The user can also obtain statistics such as intensity average and variance from selected regions.« less

  6. Determination of trace amount of oxalic acid with zirconium(IV)-(DBS-arsenazo) by spectrophotometry

    NASA Astrophysics Data System (ADS)

    Zhai, Qing-Zhou

    2008-11-01

    A novel method is proposed for the determination of trace amount of oxalic acid in the present article. In 1.0 M hydrochloric acid medium, oxalic acid can react with the zirconium(IV) in Zr(IV)-(DBS-arsenazo) complex and replaces the DBS-arsenazo to produce a hyperchromic effect at 520 nm. The hyperchromic degree is proportional to the concentration of the oxalic acid added over a defined range. Based on this property, a new method for the spectrophotometric determination of trace oxalic acid was developed. Beer's law is held over the concentration range of 9.0 × 10 -6 to 5.0 × 10 -4 M for oxalic acid with a correlation coefficient of 0.9995. The apparent molar absorptivity of the method is ɛ520 nm = 1.16 × 10 3 L mol -1 cm -1 and the detection limit for oxalic acid is 0.815 μg/mL. The developed method was directly applied to the determination of oxalic acid in tomato samples with satisfactory results.

  7. Evidence for an elemental sulfur component of the clouds from Venus spectrophotometry

    NASA Technical Reports Server (NTRS)

    Hapke, B.; Nelson, R.

    1975-01-01

    The decrease in the reflectivity of Venus in the near-UV can be explained if the clouds contain particles of elemental sulfur in addition to sulfuric acid. The low-resolution McDonald-Pittsburgh spectrum can be fitted by two sulfur-containing, multiple-scattering cloud models: (1) a mixed cloud consisting of one particle of elemental sulfur of radius 10 microns for every 670 particles of sulfuric acid of radius 1 micron, and (2) a layered cloud of optical thickness tau = 1.0 consisting of one-micron particles of sulfuric acid overlying a thick cloud of elemental sulfur particles of radius 3.6 microns. Some of the sulfur is incompletely polymerized. The source of the sulfur is photo-dissociation of COS, although some may also be recycled from the lower atmosphere. The sulfur plays a crucial role in the planetary meteorology of Venus since it is responsible for the bulk of the absorption of solar energy.

  8. Flow injection spectrophotometry using natural reagent from Morinda citrifolia root for determination of aluminium in tea.

    PubMed

    Tontrong, Sopa; Khonyoung, Supada; Jakmunee, Jaroon

    2012-05-01

    A flow injection (FI) spectrophotometric method with using natural reagent extracted from Morinda citrifolia root has been developed for determination of aluminium. The extract contained anthraquinone compounds which could react with Al(3+) to form reddish complexes which had maximum absorption wavelength at 499.0nm. The extract could be used as a reagent in FI system without further purification to obtain pure compound. A sensitive method for determination of aluminium in concentration range of 0.1-1.0mgL(-1), with detection limit of 0.05mgL(-1) was achieved. Relative standard deviations of 1.2% and 1.7% were obtained for the determination of 0.1 and 0.6mgL(-1) Al(3+) (n=11). Sample throughput of 35h(-1) was achieved with the consumption of 3mL each of carrier and reagent solutions per injection. The developed method was successfully applied to tea samples, validated by the FAAS standard method. The method is simple, fast, economical and could be classified as a greener analytical method.

  9. Milli-tesla NMR and spectrophotometry of liquids hyperpolarized by dissolution dynamic nuclear polarization

    NASA Astrophysics Data System (ADS)

    Zhu, Yue; Chen, Chia-Hsiu; Wilson, Zechariah; Savukov, Igor; Hilty, Christian

    2016-09-01

    Hyperpolarization methods offer a unique means of improving low signal strength obtained in low-field NMR. Here, simultaneous measurements of NMR at a field of 0.7 mT and laser optical absorption from samples hyperpolarized by dissolution dynamic nuclear polarization (D-DNP) are reported. The NMR measurement field closely corresponds to a typical field encountered during sample injection in a D-DNP experiment. The optical spectroscopy allows determination of the concentration of the free radical required for DNP. Correlation of radical concentration to NMR measurement of spin polarization and spin-lattice relaxation time allows determination of relaxivity and can be used for optimization of the D-DNP process. Further, the observation of the nuclear Overhauser effect originating from hyperpolarized spins is demonstrated. Signals from 1H and 19F in a mixture of trifluoroethanol and water are detected in a single spectrum, while different atoms of the same type are distinguished by J-coupling patterns. The resulting signal changes of individual peaks are indicative of molecular contact, suggesting a new application area of hyperpolarized low-field NMR for the determination of intermolecular interactions.

  10. Quantitation of Pyrantel Pamoate in Pharmaceuticals Using Permanganate by Visible Spectrophotometry

    NASA Astrophysics Data System (ADS)

    Rajendraprasad, N.; Basavaiah, K.

    2014-03-01

    Two simple, accurate and precise spectrophotometric methods are developed and validated for the assay of pyrantel pamoate (PP) in pharmaceuticals. The methods employ the oxidative property of potassium permanganate (KMnO4) in acidic and alkaline conditions. In the first method (method A), PP is converted into its free base, pyrantel (PR), and treated with known excess of KMnO4 in acidic condition followed by the measurement of unreacted KMnO4 at 550 nm. Method B is based on the registration of absorbance of green colored chromogen formed due to the reduction of KMnO4 by PP in alkaline condition. The methods obeyed Beer's law over a range of 1-20 μg/ml in inverse manner, and 0.75-15 μg/ml for method A and method B, respectively, with apparent molar absorptivity values of 1.05ṡ104 and 2.85ṡ104 lṡmol-1ṡcm-1. The optical parameters such as limits of detection (LOD), quantification (LOQ), and the Sandell sensitivity values are also reported. The accuracy and precision of the methods are assessed on intra- and inter-day basis. A recovery study by standard addition procedure is also carried out for further assurance of accuracy. The developed methods are successfully applied to determine PP in tablets. The results are more satisfactory as per current ICH guidelines.

  11. Enhanced spectrophotometric determination of chromium (VI) with diphenylcarbazide using internal standard and derivative spectrophotometry.

    PubMed

    Wróbel, K; Wróbel, K; López-de-Alba, P L; López-Martínez, L

    1997-11-01

    In the present work, erioglaucine A was applied as internal standard to enhanced spectrophotometric determination of chromium (VI) with diphenylcarbazide. The following procedure was used: (1) addition of internal standard and formation of ion pairs of Cr (VI) with benzyltributylammonium bromide (BTAB) (sample volume 100 ml), (2) extraction to 10 ml of methylene chloride, (3) evaporation in nitrogen stream, and (4) redissolution in a micro-volume with addition of diphenylcarbazide for color development (final volume 200 mul). The preconcentration factor achieved was about 400 and it was shown that, using internal standard, the analytical errors due to sample treatment were reduced. The analytical signals for chromium and internal standard were obtained at 591.30 and 653.50 nm from first derivative spectra, normalized against (1)D(653.50nm). The analytical characteristics evaluated were: detection limit = 0.06 mug l(-1), quantification limit = 0.19 mug l(-1), precision for 1 mug l(-1) 14.2%, and for 10 mug l(-1) 3.2%, correlation coefficient of linear regression was 0.9985. The proposed procedure was applied to determination of chromium (VI) in tap water. Total chromium was determined by electrothermal atomic absorption spectrometry, the recovery of hexavalent chromium added was then evaluated and compared with the results of the proposed procedure. In this experiment, good agreement was obtained between results obtained by the two methods. PMID:18966962

  12. Imaging Spectrophotometry of the Jet/ISM Interaction in IC5063

    NASA Technical Reports Server (NTRS)

    Cecil, G.; Schuft, B.; Morse, J.; Bland-Hawthorn, J.

    2004-01-01

    IC5063 is a somewhat dusty z=0.0110 S0 galaxy with a Seyfert 2 nucleus. It has a triple radio source that spans 3 arcsec, mostly blueshifted H I absorption that spans 700 km/s, and ionization cones that extend for more than 2 arcmins. We obtained fully sampled [O III]\\lambda5007 grids at 0."9 and 70 km/s FWHM resolution using the Rutgers Fabry-Perot system on the Blanco 4m telescope. Complementary long-slit spectra using the RC spectrograph on the Blanco, and Taurus Tunable Filter spectral images in H\\alpha and [N II]\\lambda6583, were also obtained to assess gaseous ionization conditions. We present the results of our analysis, and correlate spectral structures to those visible in archival WFPC2 images. We find that, in the region near the radio triple, gaseous ionization and line velocity width is tightly correlated, in excellent quantitative agreement with the high-velocity shock regime in the diagnostic emission-line ratio diagrams of Dopita & Sutherland. We separate kinematically gas in normal disk rotation that is illuminated by the AGN in the ionization cones from that agitated mechanically by the jet, and assess the energy input from both processes.

  13. Pea Plants Show Risk Sensitivity.

    PubMed

    Dener, Efrat; Kacelnik, Alex; Shemesh, Hagai

    2016-07-11

    Sensitivity to variability in resources has been documented in humans, primates, birds, and social insects, but the fit between empirical results and the predictions of risk sensitivity theory (RST), which aims to explain this sensitivity in adaptive terms, is weak [1]. RST predicts that agents should switch between risk proneness and risk aversion depending on state and circumstances, especially according to the richness of the least variable option [2]. Unrealistic assumptions about agents' information processing mechanisms and poor knowledge of the extent to which variability imposes specific selection in nature are strong candidates to explain the gap between theory and data. RST's rationale also applies to plants, where it has not hitherto been tested. Given the differences between animals' and plants' information processing mechanisms, such tests should help unravel the conflicts between theory and data. Measuring root growth allocation by split-root pea plants, we show that they favor variability when mean nutrient levels are low and the opposite when they are high, supporting the most widespread RST prediction. However, the combination of non-linear effects of nitrogen availability at local and systemic levels may explain some of these effects as a consequence of mechanisms not necessarily evolved to cope with variance [3, 4]. This resembles animal examples in which properties of perception and learning cause risk sensitivity even though they are not risk adaptations [5]. PMID:27374342

  14. Casimir experiments showing saturation effects

    SciTech Connect

    Sernelius, Bo E.

    2009-10-15

    We address several different Casimir experiments where theory and experiment disagree. First out is the classical Casimir force measurement between two metal half spaces; here both in the form of the torsion pendulum experiment by Lamoreaux and in the form of the Casimir pressure measurement between a gold sphere and a gold plate as performed by Decca et al.; theory predicts a large negative thermal correction, absent in the high precision experiments. The third experiment is the measurement of the Casimir force between a metal plate and a laser irradiated semiconductor membrane as performed by Chen et al.; the change in force with laser intensity is larger than predicted by theory. The fourth experiment is the measurement of the Casimir force between an atom and a wall in the form of the measurement by Obrecht et al. of the change in oscillation frequency of a {sup 87}Rb Bose-Einstein condensate trapped to a fused silica wall; the change is smaller than predicted by theory. We show that saturation effects can explain the discrepancies between theory and experiment observed in all these cases.

  15. Energy Absorption in a Shear-Thickening Fluid

    NASA Astrophysics Data System (ADS)

    Afeshejani, Seyed Hossein Amiri; Sabet, Seyed Ali Reza; Zeynali, Mohammad Ebrahim; Atai, Mohammad

    2014-12-01

    This study investigates energy absorption in a shear-thickening fluid (STF) containing nano-size fumed silica as a suspending material. Fumed silica particles in 20, 30, and 40 wt.% were used in polyethylene glycol and ethylene glycol. Three areas were studied, namely: energy absorption of STF pre-impregnated aramid fabric, neat STF under high-velocity impact, and flexible foam soaked in STF under low-velocity drop weight impact. Results showed moderate energy absorption in STF pre-impregnated aramid fabric compared to dry fabric. High-velocity impact tests also revealed higher fabric weave density, and multi-layered target plays vital role in optimum performance of SFT impregnated targets. High-velocity impact tests on the neat STF showed good energy absorption at velocities near STF critical shear rate. Low-velocity drop weight impact test on flexible foam soaked in STF also indicated significant energy absorption.

  16. CO2 Capture from Flue Gas by Phase Transitional Absorption

    SciTech Connect

    Liang Hu

    2009-06-30

    A novel absorption process called Phase Transitional Absorption was invented. What is the Phase Transitional Absorption? Phase Transitional Absorption is a two or multi phase absorption system, CO{sub 2} rich phase and CO{sub 2} lean phase. During Absorption, CO{sub 2} is accumulated in CO{sub 2} rich phase. After separating the two phases, CO{sub 2} rich phase is forward to regeneration. After regeneration, the regenerated CO{sub 2} rich phase combines CO{sub 2} lean phase to form absorbent again to complete the cycle. The advantage for Phase Transitional Absorption is obvious, significantly saving on regeneration energy. Because CO{sub 2} lean phase was separated before regeneration, only CO{sub 2} rich phase was forward to regeneration. The absorption system we developed has the features of high absorption rate, high loading and working capacity, low corrosion, low regeneration heat, no toxic to environment, etc. The process evaluation shows that our process is able to save 80% energy cost by comparing with MEA process.

  17. [Intestinal absorption kinetics of Polygonum capitatum extract in rats].

    PubMed

    Yang, Wu; Hou, Jia; Lu, Yuan; Chen, Peng-cheng; Liao, Shang-gao; Huang, Yong

    2015-11-01

    A UPLC-ESI-MS/MS method was used to determinate the main active fractions gallic acid, protocatechuic acid, myricetrin, hyperoside and quercitrin in Polygonum capitatum extracts by in situ intestinal perfusion models; the absorption rate constants and cumulative penetration rate of absorption were calculated. The effect of different drug concentrations, different intestine segments, bile and P-gp inhibitors on the absorption mechanism of Gallic acid and other compositions in P. capitatum extracts. The experimental results showed that gallic acid, protocatechuic acid, myricetrin and quercitrin were observed saturated at high concentration (P < 0.05). Bile had significant inhibition effect on protocatechuic acid absorption and had promotion effect on myricetrin and hyperoside absorption (P < 0.05). P-gp inhibitor verapamil could significantly enhance the absorption of Protocatechuic acid (P < 0.05). The overall trend for absorption of various compositions was that small intestine > colon. This indicated that the absorption mechanism of P. capitatum extracts in rat intestine was in line with fist-order kinetics characteristics. The composition could be absorbed in all of the different intestinal segments, and the absorption was mainly concentrated in small intestine. The protocatechuic acid may be the substrate of P-gp.

  18. [Intestinal absorption kinetics of Polygonum capitatum extract in rats].

    PubMed

    Yang, Wu; Hou, Jia; Lu, Yuan; Chen, Peng-cheng; Liao, Shang-gao; Huang, Yong

    2015-11-01

    A UPLC-ESI-MS/MS method was used to determinate the main active fractions gallic acid, protocatechuic acid, myricetrin, hyperoside and quercitrin in Polygonum capitatum extracts by in situ intestinal perfusion models; the absorption rate constants and cumulative penetration rate of absorption were calculated. The effect of different drug concentrations, different intestine segments, bile and P-gp inhibitors on the absorption mechanism of Gallic acid and other compositions in P. capitatum extracts. The experimental results showed that gallic acid, protocatechuic acid, myricetrin and quercitrin were observed saturated at high concentration (P < 0.05). Bile had significant inhibition effect on protocatechuic acid absorption and had promotion effect on myricetrin and hyperoside absorption (P < 0.05). P-gp inhibitor verapamil could significantly enhance the absorption of Protocatechuic acid (P < 0.05). The overall trend for absorption of various compositions was that small intestine > colon. This indicated that the absorption mechanism of P. capitatum extracts in rat intestine was in line with fist-order kinetics characteristics. The composition could be absorbed in all of the different intestinal segments, and the absorption was mainly concentrated in small intestine. The protocatechuic acid may be the substrate of P-gp. PMID:27071271

  19. Optical absorption of silicon nanowires

    SciTech Connect

    Xu, T.; Lambert, Y.; Krzeminski, C.; Grandidier, B.; Stievenard, D.; Leveque, G.; Akjouj, A.; Pennec, Y.; Djafari-Rouhani, B.

    2012-08-01

    We report on simulations and measurements of the optical absorption of silicon nanowires (NWs) versus their diameter. We first address the simulation of the optical absorption based on two different theoretical methods: the first one, based on the Green function formalism, is useful to calculate the scattering and absorption properties of a single or a finite set of NWs. The second one, based on the finite difference time domain (FDTD) method, is well-adapted to deal with a periodic set of NWs. In both cases, an increase of the onset energy for the absorption is found with increasing diameter. Such effect is experimentally illustrated, when photoconductivity measurements are performed on single tapered Si nanowires connected between a set of several electrodes. An increase of the nanowire diameter reveals a spectral shift of the photocurrent intensity peak towards lower photon energies that allow to tune the absorption onset from the ultraviolet radiations to the visible light spectrum.

  20. Gas-absorption process

    DOEpatents

    Stephenson, Michael J.; Eby, Robert S.

    1978-01-01

    This invention is an improved gas-absorption process for the recovery of a desired component from a feed-gas mixture containing the same. In the preferred form of the invention, the process operations are conducted in a closed-loop system including a gas-liquid contacting column having upper, intermediate, and lower contacting zones. A liquid absorbent for the desired component is circulated through the loop, being passed downwardly through the column, regenerated, withdrawn from a reboiler, and then recycled to the column. A novel technique is employed to concentrate the desired component in a narrow section of the intermediate zone. This technique comprises maintaining the temperature of the liquid-phase input to the intermediate zone at a sufficiently lower value than that of the gas-phase input to the zone to effect condensation of a major part of the absorbent-vapor upflow to the section. This establishes a steep temperature gradient in the section. The stripping factors below this section are selected to ensure that virtually all of the gases in the downflowing absorbent from the section are desorbed. The stripping factors above the section are selected to ensure re-dissolution of the desired component but not the less-soluble diluent gases. As a result, a peak concentration of the desired component is established in the section, and gas rich in that component can be withdrawn therefrom. The new process provides important advantages. The chief advantage is that the process operations can be conducted in a single column in which the contacting zones operate at essentially the same pressure.

  1. Intestinal Folate Absorption

    PubMed Central

    Olinger, Edward J.; Bertino, Joseph R.; Binder, Henry J.

    1973-01-01

    These studies were designed to determine whether pteroylmonoglutamic acid (PGA) at physiologic concentrations is transported across the small intestine unaltered or is reduced and methylated to the circulating folate form (5-methyltetrahydrofolate [5-MeFH4]) during absorption. [3H]PGA was incubated in vitro on the mucosal side of rat jejunum. Of the folate transferred to the serosal side, the percent identified as 5-MeFH4 by DEAE-Sephadex chromtography was inversely related to the initial mucosa PGA concentration: at 7, 20, and 2,000 nM, 44%, 34%, and 2%, respectively, was converted to 5-MeFH4. In contrast, less than 4% of the folate transferred across ileal mucosa was 5-MeFH4 when the initial mucosa concentration was 20 nM. Specific activity of dihydrofolate (DHF) reductase, the enzyme responsible for converting PGA to tetrahydrofolic acid, was measured in villus homogenates and was significantly greater in the jejunum than in the ileum. 1,000 nM methotrexate (MTX), a DHF reductase inhibitor, markedly inhibited PGA conversion to 5-MeFH4 by the jejunum. Studies of transmural flux, initial rate of mucosal entry (influx) and mucosal accumulation (uptake) of folate were also performed. Although MTX did not alter the influx of PGA, MTX decreased jejunal mucosal uptake but increased transmural movement. Transmural folate movement across ileal mucosa was greater than across jejunal mucosa although mucosal uptake was greater in the jejunum than in the ileum. These results could explain previous studies which have failed to identify conversion of PGA to 5-MeFH4 when intestinal preparations have been exposed to higher and less physiologic concentrations of PGA. Further, these studies suggest that 5-MeFH4 may be retained by the jejunal mucosa. PMID:4727453

  2. Mimas Showing False Colors #1

    NASA Technical Reports Server (NTRS)

    2005-01-01

    False color images of Saturn's moon, Mimas, reveal variation in either the composition or texture across its surface.

    During its approach to Mimas on Aug. 2, 2005, the Cassini spacecraft narrow-angle camera obtained multi-spectral views of the moon from a range of 228,000 kilometers (142,500 miles).

    The image at the left is a narrow angle clear-filter image, which was separately processed to enhance the contrast in brightness and sharpness of visible features. The image at the right is a color composite of narrow-angle ultraviolet, green, infrared and clear filter images, which have been specially processed to accentuate subtle changes in the spectral properties of Mimas' surface materials. To create this view, three color images (ultraviolet, green and infrared) were combined into a single black and white picture that isolates and maps regional color differences. This 'color map' was then superimposed over the clear-filter image at the left.

    The combination of color map and brightness image shows how the color differences across the Mimas surface materials are tied to geological features. Shades of blue and violet in the image at the right are used to identify surface materials that are bluer in color and have a weaker infrared brightness than average Mimas materials, which are represented by green.

    Herschel crater, a 140-kilometer-wide (88-mile) impact feature with a prominent central peak, is visible in the upper right of each image. The unusual bluer materials are seen to broadly surround Herschel crater. However, the bluer material is not uniformly distributed in and around the crater. Instead, it appears to be concentrated on the outside of the crater and more to the west than to the north or south. The origin of the color differences is not yet understood. It may represent ejecta material that was excavated from inside Mimas when the Herschel impact occurred. The bluer color of these materials may be caused by subtle differences in

  3. Laser Absorption by Over-Critical Plasmas

    NASA Astrophysics Data System (ADS)

    May, J.; Tonge, J.; Fiuza, F.; Fonseca, R. A.; Silva, L. O.; Mori, W. B.

    2015-11-01

    Absorption of high intensity laser light by matter has important applications to emerging sciences and technology, such as Fast Ignition ICF and ion acceleration. As such, understanding the underlying mechanisms of this absorption is key to developing these technologies. Critical features which distinguish the interaction of high intensity light - defined here as a laser field having a normalized vector potential greater than unity - are that the reaction of the material to the fields results in sharp high-density interfaces; and that the movement of the electrons is in general relativistic, both in a fluid and a thermal sense. The results of these features are that the absorption mechanisms are qualitatively distinct from those at lower intensities. We will review previous work, by our group and others, on the absorption mechanisms, and highlight current research. We will show that the standing wave structure of the reflected laser light is key to particle dynamics for normally incident lasers. The authors acknowledge the support of the Department of Energy under contract DE-NA 0001833 and the National Science Foundation under contract ACI 1339893.

  4. Gastrointestinal citrate absorption in nephrolithiasis

    NASA Technical Reports Server (NTRS)

    Fegan, J.; Khan, R.; Poindexter, J.; Pak, C. Y.

    1992-01-01

    Gastrointestinal absorption of citrate was measured in stone patients with idiopathic hypocitraturia to determine if citrate malabsorption could account for low urinary citrate. Citrate absorption was measured directly from recovery of orally administered potassium citrate (40 mEq.) in the intestinal lavage fluid, using an intestinal washout technique. In 7 stone patients citrate absorption, serum citrate levels, peak citrate concentration in serum and area under the curve were not significantly different from those of 7 normal subjects. Citrate absorption was rapid and efficient in both groups, with 96 to 98% absorbed within 3 hours. The absorption of citrate was less efficient from a tablet preparation of potassium citrate than from a liquid preparation, probably due to a delayed release of citrate from wax matrix. However, citrate absorption from solid potassium citrate was still high at 91%, compared to 98% for a liquid preparation. Thus, hypocitraturia is unlikely to be due to an impaired gastrointestinal absorption of citrate in stone patients without overt bowel disease.

  5. Percutaneous absorption of Octopirox.

    PubMed

    Black, J G; Kamat, V B

    1988-01-01

    containing 1% Octopirox is 29,400, so that the possibility of systemic effects due to absorption through the skin is remote. PMID:3345970

  6. Resonant Absorption of Bessel Beams

    NASA Astrophysics Data System (ADS)

    Fan, J.; Parra, E.; Milchberg, H. M.

    1999-11-01

    We report the first observation of enhanced laser-plasma optical absorption in a subcritical density plasma resulting from spatial resonances, here in the laser breakdown of a gas with a Bessel beam. The enhancement in absorption is directly correlated to enhancements both in confinement of laser radiation to the plasma and in its heating. Under certain conditions, azimuthal asymmetry in the laser beam is essential for efficient gas breakdown. Simulations of this absorption consistently explain the experimental observations. This work is supported by the National Science Foundation (PHY-9515509) and the US Department of Energy (DEF G0297 ER 41039).

  7. Impedance Matched Absorptive Thermal Blocking Filters

    NASA Technical Reports Server (NTRS)

    Wollack, E. J.; Chuss, D. T.; U-Yen, K.; Rostem, K.

    2014-01-01

    We have designed, fabricated and characterized absorptive thermal blocking filters for cryogenic microwave applications. The transmission line filter's input characteristic impedance is designed to match 50 Omega and its response has been validated from 0-to-50GHz. The observed return loss in the 0-to-20GHz design band is greater than 20 dB and shows graceful degradation with frequency. Design considerations and equations are provided that enable this approach to be scaled and modified for use in other applications.

  8. Impedance Matched Absorptive Thermal Blocking Filters

    NASA Technical Reports Server (NTRS)

    Wollack, E. J.; Chuss, D. T.; Rostem, K.; U-Yen, K.

    2014-01-01

    We have designed, fabricated and characterized absorptive thermal blocking filters for cryogenic microwave applications. The transmission line filter's input characteristic impedance is designed to match 50O and its response has been validated from 0-to-50GHz. The observed return loss in the 0-to-20GHz design band is greater than 20 dB and shows graceful degradation with frequency. Design considerations and equations are provided that enable this approach to be scaled and modified for use in other applications.

  9. Transient simulation of absorption machines

    NASA Astrophysics Data System (ADS)

    Anand, D. K.; Allen, R. W.; Kumar, B.

    1982-08-01

    This paper presents a model for a water-cooled Lithium-Bromide/water absorption chiller and predicts its transient response both during the start-up phase and during the shutoff period. The simulation model incorporates such influencing factors as the thermodynamic properties of the working fluid, the absorbent, the heat-transfer configuration of different components of the chiller and related physical data. The time constants of different components are controlled by a set of key parameters that have been identified in this study. The results show a variable but at times significant amount of time delay before the chiller capacity gets close to its steady-state value. The model is intended to provide an insight into the mechanism of build-up to steady-state performance. By recognizing the significant factors contributing to transient degradation, steps can be taken to reduce such degradation. The evaluation of the residual capacity in the shut-off period will yield more realistic estimates of chiller COP for a chiller satisfying dynamic space cooling load.

  10. Exciton absorption of entangled photons in semiconductor quantum wells

    NASA Astrophysics Data System (ADS)

    Rodriguez, Ferney; Guzman, David; Salazar, Luis; Quiroga, Luis; Condensed Matter Physics Group Team

    2013-03-01

    The dependence of the excitonic two-photon absorption on the quantum correlations (entanglement) of exciting biphotons by a semiconductor quantum well is studied. We show that entangled photon absorption can display very unusual features depending on space-time-polarization biphoton parameters and absorber density of states for both bound exciton states as well as for unbound electron-hole pairs. We report on the connection between biphoton entanglement, as quantified by the Schmidt number, and absorption by a semiconductor quantum well. Comparison between frequency-anti-correlated, unentangled and frequency-correlated biphoton absorption is addressed. We found that exciton oscillator strengths are highly increased when photons arrive almost simultaneously in an entangled state. Two-photon-absorption becomes a highly sensitive probe of photon quantum correlations when narrow semiconductor quantum wells are used as two-photon absorbers. Research funds from Facultad de Ciencias, Universidad de los Andes

  11. Design of plasmonic circular grating with broadband absorption enhancements

    NASA Astrophysics Data System (ADS)

    Chiu, Nan-Fu; Yang, Cheng-Du; Kao, Yi-Lun; Cheng, Chih-Jen

    2015-05-01

    We have investigated the effect of concentric circles geometry on the performance of focusing plasmonic circular grating (PCG)-coupled surface-omnidirectional absorption. We wish to highlight the essential characteristics of plasmonic circular grating nanostructure to assist researchers in developing and advancing suitable organic solar cells (OSC) for unique applications. Exactly how plasmonic enhancement and the absorption characteristics of the organic materials (P3HT:PCBM and PEDOT:PSS) interact with each other is also examined. We present experimental studies of broadband absorption enhancement in PCG structure. We show that the PCG structure can result in broadband absorption enhancement, the overall optical absorption in organic film can be greatly enhanced up to ~111.2 % compared to the planar device without grating.

  12. Electro-absorption of silicene and bilayer graphene quantum dots

    NASA Astrophysics Data System (ADS)

    Abdelsalam, Hazem; Talaat, Mohamed H.; Lukyanchuk, Igor; Portnoi, M. E.; Saroka, V. A.

    2016-07-01

    We study numerically the optical properties of low-buckled silicene and AB-stacked bilayer graphene quantum dots subjected to an external electric field, which is normal to their surface. Within the tight-binding model, the optical absorption is calculated for quantum dots, of triangular and hexagonal shapes, with zigzag and armchair edge terminations. We show that in triangular silicene clusters with zigzag edges a rich and widely tunable infrared absorption peak structure originates from transitions involving zero energy states. The edge of absorption in silicene quantum dots undergoes red shift in the external electric field for triangular clusters, whereas blue shift takes place for hexagonal ones. In small clusters of bilayer graphene with zigzag edges the edge of absorption undergoes blue/red shift for triangular/hexagonal geometry. In armchair clusters of silicene blue shift of the absorption edge takes place for both cluster shapes, while red shift is inherent for both shapes of the bilayer graphene quantum dots.

  13. Quantum Entanglement Molecular Absorption Spectrum Simulator

    NASA Technical Reports Server (NTRS)

    Nguyen, Quang-Viet; Kojima, Jun

    2006-01-01

    Quantum Entanglement Molecular Absorption Spectrum Simulator (QE-MASS) is a computer program for simulating two photon molecular-absorption spectroscopy using quantum-entangled photons. More specifically, QE-MASS simulates the molecular absorption of two quantum-entangled photons generated by the spontaneous parametric down-conversion (SPDC) of a fixed-frequency photon from a laser. The two-photon absorption process is modeled via a combination of rovibrational and electronic single-photon transitions, using a wave-function formalism. A two-photon absorption cross section as a function of the entanglement delay time between the two photons is computed, then subjected to a fast Fourier transform to produce an energy spectrum. The program then detects peaks in the Fourier spectrum and displays the energy levels of very short-lived intermediate quantum states (or virtual states) of the molecule. Such virtual states were only previously accessible using ultra-fast (femtosecond) laser systems. However, with the use of a single-frequency continuous wave laser to produce SPDC photons, and QEMASS program, these short-lived molecular states can now be studied using much simpler laser systems. QE-MASS can also show the dependence of the Fourier spectrum on the tuning range of the entanglement time of any externally introduced optical-path delay time. QE-MASS can be extended to any molecule for which an appropriate spectroscopic database is available. It is a means of performing an a priori parametric analysis of entangled photon spectroscopy for development and implementation of emerging quantum-spectroscopic sensing techniques. QE-MASS is currently implemented using the Mathcad software package.

  14. Percutaneous nitroglycerin absorption in rats.

    PubMed

    Horhota, S T; Fung, H L

    1979-05-01

    Percutaneous nitroglycerin absorption was studied in shaved rats by monitoring unchanged plasma drug concentrations for up to 4 hr. Drug absorption from the neat liquid state or from an alcoholic solution was considerably poorer than that from a commercial ointment. This observation was unanticipated since the driving force for percutaneous drug absorption was assumed to be drug thermodynamics. Potential artifacts such as drug volatilization from the skin, reduction of surface area through droplet formation, and vehicle occlusion were investigated, but they did not appear to be responsible for the observed results. Two experimental aqueous nitroglycerin gels were prepared with polyethylene glycol 400. One gel contained just sufficient polyethylene glycol to solubilize the nitroglycerin; the other had excess polyethylene glycol to solubilize nitroglycerin far below saturation. Both gels gave extremely low plasma nitroglycerin levels. The composite data suggested that percutaneous nitroglycerin absorption is highly vehicle dependent and that this dependency cannot be explained by simple consideration of drug thermodynamic activity.

  15. Circadian Regulation of Macronutrient Absorption.

    PubMed

    Hussain, M Mahmood; Pan, Xiaoyue

    2015-12-01

    Various intestinal functions exhibit circadian rhythmicity. Disruptions in these rhythms as in shift workers and transcontinental travelers are associated with intestinal discomfort. Circadian rhythms are controlled at the molecular level by core clock and clock-controlled genes. These clock genes are expressed in intestinal cells, suggesting that they might participate in the circadian regulation of intestinal functions. A major function of the intestine is nutrient absorption. Here, we will review absorption of proteins, carbohydrates, and lipids and circadian regulation of various transporters involved in their absorption. A better understanding of circadian regulation of intestinal absorption might help control several metabolic disorders and attenuate intestinal discomfort associated with disruptions in sleep-wake cycles.

  16. Simultaneous determination of domperidone maleate and cinnarizine in a binary mixture using derivative ratio spectrophotometry and classical least squares calibration.

    PubMed

    Salem, Maissa Y; El-Bardicy, Mohamed G; El-Tarras, Mohamed F; El-Zanfally, Eman S

    2002-08-22

    This work is concerned with the simultaneous determination of domperidone maleate (DOM) and cinnarizine (CINN) in a binary mixture form without previous separation by two different methods. The first method is the application of derivative ratio spectrophotometry where the linearity range was 2.5-30 micro g/ml, 2.5-25 micro g/ml for DOM and CINN, respectively, and percentage recoveries were 100.26+/-1.308 and 99.86+/-0.939 for DOM and CINN, respectively, in their laboratory prepared mixtures. The second method depends on the application of classical least squares (CLS) calibration model. Two training sets were constructed and the best model was used for the prediction of the concentrations of both drugs. The proposed procedures were successfully applied for the simultaneous determination of both drugs in laboratory prepared mixtures and in commercial tablet preparations. The validity of the proposed methods was assessed by applying the standard addition technique where the percentage recovery of the added standard was found to be 99.83+/-1.861 and 98.38+/-0.871 for DOM and CINN, respectively, using the derivative ratio method and 99.53+/-0.916 and 99.39+/-0.599 for DOM and CINN, respectively, using the CLS method. The proposed procedures are rapid, simple, require no preliminary separation steps and can, therefore, be used routine analysis of both drugs in quality control laboratories. PMID:12151062

  17. Molybdenum blue spectrophotometry for trace arsenic in ground water using a soluble membrane filter and calcium carbonate column.

    PubMed

    Okazaki, Takuya; Wang, Wenjing; Kuramitz, Hideki; Hata, Noriko; Taguchi, Shigeru

    2013-01-01

    An improved molybdenum blue spectrophotometry using a soluble membrane filter and CaCO(3)-column was proposed for determining arsenic in drinking water supplied from ground water in the presence of phosphate. A 100 mL sample solution containing 0.5 - 10 μg arsenic was passed through a CaCO(3)-column to remove phosphate, arsenate (As(V)). Arsenite (As(III)) which was not retained on the column was oxidized to As(V). As(V) was converted into a heteropolymolybdenum blue anion. The blue anion was collected on a membrane filter as an ion-associate with n-dodecyltrimethylammonium ion by filtration. The filter was dissolved in 2 mL of 2-methoxyethanol. The absorbance of the solution was measured at 810 nm against a reagent blank. Total inorganic arsenic was determined by reducing As(V) to As(III) before the column treatment. The RSDs for 10 μg L(-1) of As(III) and As(V) were 2.9%. Phosphate 0.2 mg L(-1) (as P) and iron 0.1 mg L(-1) did not interfere with the determination of 10 μg L(-1) arsenic. The proposed method was successfully applied to ground waters.

  18. Episodes of apnea and bradycardia in the preterm newborn: impact on cerebral oxygenation measured by near-infrared spectrophotometry

    NASA Astrophysics Data System (ADS)

    Van Huffel, Sabine; Craemers, Johan; Lenaerts, Bart; Daniels, Hans; Naulaers, Gunnar; Casaer, Paul

    1998-12-01

    The objective of this study is to evaluate the effect of episodes of apneas and/or mild bradycardia (heart rate decreases of 10 to 20% or more) on cerebral oxyhemoglobin (HbO2) and reduced hemoglobin (Hb) concentration as measured by Near Infrared Spectrophotometry (NIRS). Measurements were carried out on 7 preterm infants who experienced apneic and bradycardiac events. It is shown how to characterize these events using time-frequency analysis. In addition to NIRS (performed with a NIRO-500 from Hamamatsu, Japan), the heart rate, ECG, peripheral arterial oxygen saturation (measured at the foot) and respiration (abdominal and thoracic pressure, and nasal airflow) were continuously recorded. The impact of apneic events and periodic breathing on these measurements reveals the clinical relevance of NIRS. In particular, we investigate whether these changes in heart rate and respiration also influence HbO2 and reduced Hb concentration in neonatal brain. These changes are characterized, as well as their relationships with the other simultaneously recorded signals such as peripheral arterial oxygen saturation.

  19. Rapid determination of trace thiabendazole in apple juice utilizing dispersive liquid-liquid microextraction combined with fluorescence spectrophotometry.

    PubMed

    Li, Wei; Wang, Yuning; Huang, Limin; Wu, Ting; Hu, Huilian; Du, Yiping

    2015-09-01

    Food safety has become a large concern and prompts an urgent need for the development of rapid, simple and sensitive analytical methods that can monitor pesticide residues in foods. This study aimed to provide a method for quantitative determination of trace thiabendazole in apple juice. Due to its high sensitivity and selectivity, fluorescence spectrophotometry was utilized as a front end to dispersive liquid-liquid microextraction (DLLME). The experimental parameters that influenced the extraction were systematically investigated. Under optimum conditions, the whole procedure, including DLLME and analysis of one sample, was carried out within 5 min, and linearity was found in the 5-50 µg/L range with a correlation coefficient (r) of 0.9987. The limit of detection value was 2.2 µg/L. Good reproducibility was achieved based with a less than 4.5% relative standard deviation (RSD) for five replicates at different sample concentrations. This method was shown to be suitable for rapid and sensitive quantification of thiabendazole in apple juice.

  20. Study of monoprotic acid-base equilibria in aqueous micellar solutions of nonionic surfactants using spectrophotometry and chemometrics.

    PubMed

    Babamoradi, Hamid; Abdollahi, Hamid

    2015-10-01

    Many studies have shown the distribution of solutes between aqueous phase and micellar pseudo-phase in aqueous micellar solutions. However, spectrophotometric studies of acid-base equilibria in these media do not confirm such distribution because of the collinearity between concentrations of chemical species in the two phases. The collinearity causes the number of detected species to be equal to the number of species in a homogenous solution that automatically misinterpreted as homogeneity of micellar solutions, therefore the collinearity is often neglected. This interpretation is in contradiction to the distribution theory in micellar media that must be avoided. Acid-base equilibrium of an indicator was studied in aqueous micellar solutions of a nonionic surfactant to address the collinearity using UV/Visible spectrophotometry. Simultaneous analysis (matrix augmentation) of the equilibrium and solvation data was applied to eliminate the collinearity from the equilibrium data. A model was then suggested for the equilibrium that was fitted to the augmented data to estimate distribution coefficients of the species between the two phases. Moreover, complete resolution of concentration and spectral profiles of species in each phase was achieved.

  1. Inter-laboratory verification of European pharmacopoeia monograph on derivative spectrophotometry method and its application for chitosan hydrochloride.

    PubMed

    Marković, Bojan; Ignjatović, Janko; Vujadinović, Mirjana; Savić, Vedrana; Vladimirov, Sote; Karljiković-Rajić, Katarina

    2015-01-01

    Inter-laboratory verification of European pharmacopoeia (EP) monograph on derivative spectrophotometry (DS) method and its application for chitosan hydrochloride was carried out on two generation of instruments (earlier GBC Cintra 20 and current technology TS Evolution 300). Instruments operate with different versions of Savitzky-Golay algorithm and modes of generating digital derivative spectra. For resolution power parameter, defined as the amplitude ratio A/B in DS method EP monograph, comparable results were obtained only with algorithm's parameters smoothing points (SP) 7 and the 2nd degree polynomial and those provided corresponding data with other two modes on TS Evolution 300 Medium digital indirect and Medium digital direct. Using quoted algorithm's parameters, the differences in percentages between the amplitude ratio A/B averages, were within accepted criteria (±3%) for assay of drug product for method transfer. The deviation of 1.76% for the degree of deacetylation assessment of chitosan hydrochloride, determined on two instruments, (amplitude (1)D202; the 2nd degree polynomial and SP 9 in Savitzky-Golay algorithm), was acceptable, since it was within allowed criteria (±2%) for assay deviation of drug substance, for method transfer in pharmaceutical analyses.

  2. High-performance liquid chromatography and derivative spectrophotometry for simultaneous determination of pravastatin and fenofibrate in the dosage form.

    PubMed

    Hefnawy, Mohamed M; Mohamed, Mostafa S; Abounassif, Mohammed A; Alanazi, Amer M; Mostafa, Gamal A E

    2014-12-01

    High performance liquid chromatography (HPLC) and second-order derivative spectrophotometry have been used for simultaneous determination of pravastatin (PS) and fenofibrate (FF) in pharmaceutical formulations. HPLC separation was performed on a phenyl HYPERSIL C18 column (125 mm × 4.6 mm i.d., 5 μm particle diameter) in the isocratic mode using a mobile phase acetonitrile/0.1 % diethyl amine (50:50, V/V, pH 4.5) pumped at a flow rate of 1.0 mL min-1. Measurement was made at 240 nm. Both drugs were well resolved on the stationary phase, with retention times of 2.15 and 5.79 min for PS and FF, respectively. Calibration curves were linear (R = 0.999 for PS and 0.996 for FF) in the concentration range of 5-50 and 20-200 µg mL-1 for PS and FF, respectively. Pravastatin and fenofibrate were quantitated in combined preparations also using the second-order derivative response at 237.6 and 295.1 nm for PS and FF, respectively. Calibration curves were linear, with the correlation coefficient R = 0.999 for pravastatin and fenofibrate, in the concentration range of 5-20 and 3-20 µg mL-1 for PS and FF, respectively. Both methods were fully validated and compared, the results confirmed that they were highly suitable for their intended purpose.

  3. Measuring Binding Affinity of Protein-Ligand Interaction Using Spectrophotometry: Binding of Neutral Red to Riboflavin-Binding Protein

    ERIC Educational Resources Information Center

    Chenprakhon, Pirom; Sucharitakul, Jeerus; Panijpan, Bhinyo; Chaiyen, Pimchai

    2010-01-01

    The dissociation constant, K[subscript d], of the binding of riboflavin-binding protein (RP) with neutral red (NR) can be determined by titrating RP to a fixed concentration of NR. Upon adding RP to the NR solution, the maximum absorption peak of NR shifts to 545 nm from 450 nm for the free NR. The change of the absorption can be used to determine…

  4. Use of HPLC/UPLC-spectrophotometry for detection of formazan in in vitro Reconstructed human Tissue (RhT)-based test methods employing the MTT-reduction assay to expand their applicability to strongly coloured test chemicals.

    PubMed

    Alépée, N; Barroso, J; De Smedt, A; De Wever, B; Hibatallah, J; Klaric, M; Mewes, K R; Millet, M; Pfannenbecker, U; Tailhardat, M; Templier, M; McNamee, P

    2015-06-01

    A number of in vitro test methods using Reconstructed human Tissues (RhT) are regulatory accepted for evaluation of skin corrosion/irritation. In such methods, test chemical corrosion/irritation potential is determined by measuring tissue viability using the photometric MTT-reduction assay. A known limitation of this assay is possible interference of strongly coloured test chemicals with measurement of formazan by absorbance (OD). To address this, Cosmetics Europe evaluated use of HPLC/UPLC-spectrophotometry as an alternative formazan measurement system. Using the approach recommended by the FDA guidance for validation of bio-analytical methods, three independent laboratories established and qualified their HPLC/UPLC-spectrophotometry systems to reproducibly measure formazan from tissue extracts. Up to 26 chemicals were then tested in RhT test systems for eye/skin irritation and skin corrosion. Results support that: (1) HPLC/UPLC-spectrophotometry formazan measurement is highly reproducible; (2) formazan measurement by HPLC/UPLC-spectrophotometry and OD gave almost identical tissue viabilities for test chemicals not exhibiting colour interference nor direct MTT reduction; (3) independent of the test system used, HPLC/UPLC-spectrophotometry can measure formazan for strongly coloured test chemicals when this is not possible by absorbance only. It is therefore recommended that HPLC/UPLC-spectrophotometry to measure formazan be included in the procedures of in vitro RhT-based test methods, irrespective of the test system used and the toxicity endpoint evaluated to extend the applicability of these test methods to strongly coloured chemicals.

  5. Evaluation of intensity and energy interaction parameters for the complexation of Pr(III) with selected nucleoside and nucleotide through absorption spectral studies.

    PubMed

    Bendangsenla, N; Moaienla, T; David Singh, Th; Sumitra, Ch; Rajmuhon Singh, N; Indira Devi, M

    2013-02-15

    The interactions of Pr(III) with nucleosides and nucleotides have been studied in different organic solvents employing absorption difference and comparative absorption spectrophotometry. The magnitudes of the variations in both energy and intensity interaction parameters were used to explore the degree of outer and inner sphere co-ordination, incidence of covalency and the extent of metal 4f-orbital involvement in chemical bonding. Various electronic spectral parameters like Slater-Condon (F(k)), Racah (E(k)), Lande parameter (ξ(4f)), Nephelauxatic ratio (β), bonding (b(1/2)), percentage covalency (δ) and intensity parameters like oscillator strength (P) and Judd Ofelt electronic dipole intensity parameter (T(λ), λ=2,4,6) have been evaluated. The variation of these evaluated parameters were employed to interpret the nature of binding of Pr(III) with different ligands i.e. Adenosine/ATP in presence and absence of Ca(2+).

  6. Selective determination of antimony(III) and antimony(V) with ammonium pyrrolidinedithiocarbamate, sodium diethyldithiocarbamate and dithizone by atomic-absorption spectrometry with a carbon-tube atomizer.

    PubMed

    Kamada, T; Yamamoto, Y

    1977-05-01

    The extraction behaviour of antimony(III) and antimony(V) with ammonium pyrrolidinedithiocarbamate, sodium diethyldithiocarbamate and dithizone in organic solvents has been investigated by means of frameless atomic-absorption spectrophotometry with a carbon-tube atomizer. The selective extraction of antimony(III) and differential determination of antimony(III) and antimony(V) have been developed. With ammonium pyrrolidinedithiocarbamate and methyl isobutyl ketone, when the aqueous phase/solvent volume ratio is 50 ml/10 ml and the injection volume in the carbon tube is 20 mul, the sensitivity for antimony is 0.2 ng/ml for 1% absorption. The relative standard deviations are ca. 2%. Interferences by many metal ions can be prevented by masking with EDTA. The proposed methods have been applied satisfactorily to determination of antimony(III) and antimony(V) in various types of water. PMID:18962096

  7. Study of the absorption spectra of the 4f electron transitions of the praseodymium complex with ciprofloxacin and its analytical application.

    PubMed

    Wei, J; Naixing, W; Quanjie, M; Zhikun, S; Xiuqin, X; Fuxiang, L

    2001-08-01

    Ciprofloxacin (CPFX) is proposed as a reagent for the derivative spectrophotometric determination of praseodymium in mixed rare earths. The absorption spectra of 4f electron transitions of the praseodymium complex with CPFX was studied by normal and derivative spectrophotometry. The stoichiometry of the praseodymium-CPFX complex was calculated by the molar ratio and continuous variations methods. A ratio of Pr to CPFX of 1:3 was found. The absorption bands of the 4f electron transitions of the complex were enhanced markedly. Using the third derivative spectrum. Beer's law was obeyed up to 35 microg cm(-3) of praseodymium. The relative standard deviation is 0.62% for 14 microg cm(-3) of praseodymium. The detection and quantification limits were 0.17 and 0.56 microg cm(-3) of praseodymium, respectively. A method for the direct determination of praseodymium in mixtures of rare earths with good accuracy and selectivity is described.

  8. Determination of gold, indium, tellurium and thallium in the same sample digest of geological materials by atomic-absorption spectroscopy and two-step solvent extraction

    USGS Publications Warehouse

    Hubert, A.E.; Chao, T.T.

    1985-01-01

    A rock, soil, or stream-sediment sample is decomposed with hydrofluoric acid, aqua regia, and hydrobromic acid-bromine solution. Gold, thallium, indium and tellurium are separated and concentrated from the sample digest by a two-step MIBK extraction at two concentrations of hydrobromic add. Gold and thallium are first extracted from 0.1M hydrobromic acid medium, then indium and tellurium are extracted from 3M hydrobromic acid in the presence of ascorbic acid to eliminate iron interference. The elements are then determined by flame atomic-absorption spectrophotometry. The two-step solvent extraction can also be used in conjunction with electrothermal atomic-absorption methods to lower the detection limits for all four metals in geological materials. ?? 1985.

  9. Modulation of ganciclovir intestinal absorption in presence of absorption enhancers.

    PubMed

    Shah, Pranav; Jogani, Viral; Mishra, Pushpa; Mishra, Anil Kumar; Bagchi, Tamishraha; Misra, Ambikanandan

    2007-10-01

    The purpose of this investigation was to study the influences of absorption enhancers in increasing oral bioavailability of Ganciclovir (GAN) by assessing the transepithelial permeation across cell monolayers in vitro and bioavailability in rats in vivo. The permeation of GAN across Caco-2 and MDCK cell monolayers in the absence/presence of dimethyl-beta-cyclodextrin (DMbetaCD), chitosan hydrochloride (CH), sodium lauryl sulphate (SLS), and their combinations was studied for a 2-h period. GAN was administered to rats in absence/presence of absorption enhancers and drug contents in plasma were estimated. We found that the apparent permeability coefficient (Papp) of GAN in absence of absorption enhancers (control) were 0.261 +/- 0.072 x 10(-6) and 0.486 +/- 0.063 x 10(-6) cm/s in Caco-2 and MDCK cell monolayers, respectively, whereas in the presence of DMbetaCD, CH, SLS, and their combinations, Papp of GAN increased by 5- to 25-fold and 7- to 33-fold as compared to control in Caco-2 and MDCK cell monolayers, respectively. However, in rats, the maximum enhancement in bioavailability of GAN during coadministration of these absorption enhancers was only fivefold compared to GAN control. To conclude, the absorption enhancers-DMbetaCD, CH, SLS, and their combinations demonstrated significant improvement in transepithelial permeation and bioavailability of GAN.

  10. Converting Sabine absorption coefficients to random incidence absorption coefficients.

    PubMed

    Jeong, Cheol-Ho

    2013-06-01

    Absorption coefficients measured by the chamber method are referred to as Sabine absorption coefficients, which sometimes exceed unity due to the finite size of a sample and non-uniform intensity in the reverberation chambers under test. In this study, conversion methods from Sabine absorption coefficients to random incidence absorption coefficients are proposed. The overestimations of the Sabine absorption coefficient are investigated theoretically based on Miki's model for porous absorbers backed by a rigid wall or an air cavity, resulting in conversion factors. Additionally, three optimizations are suggested: An optimization method for the surface impedances for locally reacting absorbers, the flow resistivity for extendedly reacting absorbers, and the flow resistance for fabrics. With four porous type absorbers, the conversion methods are validated. For absorbers backed by a rigid wall, the surface impedance optimization produces the best results, while the flow resistivity optimization also yields reasonable results. The flow resistivity and flow resistance optimization for extendedly reacting absorbers are also found to be successful. However, the theoretical conversion factors based on Miki's model do not guarantee reliable estimations, particularly at frequencies below 250 Hz and beyond 2500 Hz.

  11. Circadian regulators of intestinal lipid absorption.

    PubMed

    Hussain, M Mahmood; Pan, Xiaoyue

    2015-04-01

    Among all the metabolites present in the plasma, lipids, mainly triacylglycerol and diacylglycerol, show extensive circadian rhythms. These lipids are transported in the plasma as part of lipoproteins. Lipoproteins are synthesized primarily in the liver and intestine and their production exhibits circadian rhythmicity. Studies have shown that various proteins involved in lipid absorption and lipoprotein biosynthesis show circadian expression. Further, intestinal epithelial cells express circadian clock genes and these genes might control circadian expression of different proteins involved in intestinal lipid absorption. Intestinal circadian clock genes are synchronized by signals emanating from the suprachiasmatic nuclei that constitute a master clock and from signals coming from other environmental factors, such as food availability. Disruptions in central clock, as happens due to disruptions in the sleep/wake cycle, affect intestinal function. Similarly, irregularities in temporal food intake affect intestinal function. These changes predispose individuals to various metabolic disorders, such as metabolic syndrome, obesity, diabetes, and atherosclerosis. Here, we summarize how circadian rhythms regulate microsomal triglyceride transfer protein, apoAIV, and nocturnin to affect diurnal regulation of lipid absorption.

  12. Dust in MG II Absorption Systems

    NASA Astrophysics Data System (ADS)

    Malhotra, S.

    The dust absorption feature at 2175 AA is detected in a composite spectrum of Mg II absorbers. The composite absorber spectrum is obtained by taking the geometric mean of 92 quasar spectra after aligning them in the rest-frame of 96 absorbers. By aligning the spectra according to absorber redshifts we reinforce the spectral features of the absorbers, and smooth over possible bumps and wiggles in the emission spectra. The width of the observed absorption feature is 200-300 AA (FWHM), or 0.4-0.6 microns^{-1} and the central wavelength is 2240 AA. The Galactic dust feature has a central wavelength of 2176 AA and FWHM = 0.8-1.25 microns^{-1}. Simulations show that this discrepancy between the properties of the 2175 AA feature in Mg II absorbers and Galactic ISM can be mostly explained by the different methods used to measure them (cf. Malhotra 1997).

  13. Exciton absorption in narrow armchair graphene nanoribbons

    NASA Astrophysics Data System (ADS)

    Monozon, B. S.; Schmelcher, P.

    2016-11-01

    We develop an analytical approach to the exciton optical absorption for narrow gap armchair graphene nanoribbons (AGNR). We focus on the regime of dominant size quantization in combination with the attractive electron-hole interaction. An adiabatic separation of slow and fast motions leads via the two-body Dirac equation to the isolated and coupled subband approximations. Discrete and continuous exciton states are in general coupled and form quasi-Rydberg series of purely discrete and resonance type character. The corresponding oscillator strengths and widths are derived. We show that the exciton peaks are blue-shifted, become broader and increase in magnitude upon narrowing the ribbon. At the edge of a subband the singularity related to the 1D density of states is transformed into finite absorption via the presence of the exciton. Our analytical results are in good agreement with those obtained by other methods including numerical approaches. Estimates of the expected experimental values are provided for realistic AGNR.

  14. Wavelength mismatch effect in electromagnetically induced absorption

    NASA Astrophysics Data System (ADS)

    Bharti, Vineet; Wasan, Ajay; Natarajan, Vasant

    2016-07-01

    We present a theoretical investigation of the phenomenon of electromagnetically induced absorption (EIA) in a 4-level system consisting of vee and ladder subsystems. The four levels are coupled using one weak probe field, and two strong control fields. We consider an experimental realization using energy levels of Rb. This necessitates dealing with different conditions of wavelength mismatch-near-perfect match where all three wavelengths are approximately equal; partial mismatch where the wavelength of one control field is less than the other fields; and complete mismatch where all three wavelengths are unequal. We present probe absorption profiles with Doppler averaging at room temperature to account for experiments in a room temperature Rb vapor cell. Our analysis shows that EIA resonances can be studied using Rydberg states excited with diode lasers.

  15. Oxidation of psychotropic drugs by Chloramine-T in acid medium: a kinetic study using spectrophotometry

    NASA Astrophysics Data System (ADS)

    Saldanha, R. J. D.; Ananda, S.; Venkatesha, B. M.; Made Gowda, N. M.

    2002-03-01

    The kinetics of oxidation of psychotropic drugs, chlorpromazine hydrochloride (CPH) and fluphenazine dihydrochloride (FPH), by Chloramine-T (CAT) in pH 1.6 buffer medium has been studied spectrophotometrically at λmax=570 and 530 nm, respectively, at 30°C. The reaction rate shows a fractional-order dependence on [CAT] and first-order dependence on each [substrate]. The reaction rate also shows an inverse fractional-order in [H +]. Additions of halide ions and the reduction product of CAT, p-toluenesulfonamide, and variation of ionic strength and dielectric constant of the medium do not have any significant effect on the reaction rate. The activation parameters for the reaction were evaluated. The proposed general mechanism and the derived rate law are consistent with the observed kinetics.

  16. Silver nanoparticles coated with natural polysaccharides as models to study AgNP aggregation kinetics using UV-Visible spectrophotometry upon discharge in complex environments.

    PubMed

    Lodeiro, Pablo; Achterberg, Eric P; Pampín, Joaquín; Affatati, Alice; El-Shahawi, Mohammed S

    2016-01-01

    This study provides quantitative information on the aggregation and dissolution behaviour of silver nanoparticles (AgNPs) upon discharge in fresh and sea waters, represented here as NaCl solutions of increasing ionic strength (up to 1M) and natural fjord waters. Natural polysaccharides, sodium alginate (ALG) and gum Arabic (GA), were used as coatings to stabilize the AgNPs and the compounds acted as models to study AgNP aggregation kinetics. The DLVO theory was used to quantitatively describe the interactions between the AgNPs. The stability of AgNPs was established using UV-Visible spectrophotometry, including unique information collected during the first seconds of the aggregaton process. Alginate coating resulted in a moderate stabilization of AgNPs in terms of critical coagulation concentration (~82mM NaCl) and a low dissolution of <10% total Ag in NaCl solutions up to 1M. Gum Arabic coated AgNPs were more strongly stabilized, with ~7-30% size increase up to 77mM NaCl, but only when the silver ion content initially present in solution was low (<10% total Ag). The ALG and GA coated AgNPs showed a strongly enhanced stability in natural fjord waters (ca. 5h required to reduce the area of the surface plasmon resonance band (SPRB) by two fold) compared with NaCl at an equivalent ionic strength (1-2min period for a two fold SPRB reduction). This is ascribed to a stabilizing effect from dissolved organic matter present in natural fjord waters. Interestingly, for AgNP-GA solutions with 40% of total silver present as unreacted silver ions in the NP stock solution, fast aggregation kinetics were observed in NaCl solutions (SPRB area was reduced by ca. 50% within 40-150min), with even more rapid removal in fjord waters, attributed to the high amount of silver-chloride charged species, that interact with the NP coating and/or organic matter and reduce the NPs stabilization.

  17. Aprotic solvents effect on the UV-visible absorption spectra of bixin

    NASA Astrophysics Data System (ADS)

    Rahmalia, Winda; Fabre, Jean-François; Usman, Thamrin; Mouloungui, Zéphirin

    2014-10-01

    We describe here the effects of aprotic solvents on the spectroscopic characteristics of bixin. Bixin was dissolved in dimethyl sulfoxide, acetone, dichloromethane, ethyl acetate, chloroform, dimethyl carbonate, cyclohexane and hexane, separately, and its spectra in the resulting solutions were determined by UV-visible spectrophotometry at normal pressure and room temperature. We analyzed the effect of aprotic solvents on λmax according to Onsager cavity model and Hansen theory, and determined the approximate absorption coefficient with the Beer-Lambert law. We found that the UV-visible absorption spectra of bixin were found to be solvent dependent. The S0 → S2 transition energy of bixin in solution was dependent principally on the refractive index of the solvents and the bixin-solvent dispersion interaction. There was a small influence of the solvents dielectric constant, permanent dipole interaction and hydrogen bonding occurred between bixin and solvents. The absorbance of bixin in various solvents, with the exception of hexane, increased linearly with concentration.

  18. Aprotic solvents effect on the UV-visible absorption spectra of bixin.

    PubMed

    Rahmalia, Winda; Fabre, Jean-François; Usman, Thamrin; Mouloungui, Zéphirin

    2014-10-15

    We describe here the effects of aprotic solvents on the spectroscopic characteristics of bixin. Bixin was dissolved in dimethyl sulfoxide, acetone, dichloromethane, ethyl acetate, chloroform, dimethyl carbonate, cyclohexane and hexane, separately, and its spectra in the resulting solutions were determined by UV-visible spectrophotometry at normal pressure and room temperature. We analyzed the effect of aprotic solvents on λmax according to Onsager cavity model and Hansen theory, and determined the approximate absorption coefficient with the Beer-Lambert law. We found that the UV-visible absorption spectra of bixin were found to be solvent dependent. The S0→S2 transition energy of bixin in solution was dependent principally on the refractive index of the solvents and the bixin-solvent dispersion interaction. There was a small influence of the solvents dielectric constant, permanent dipole interaction and hydrogen bonding occurred between bixin and solvents. The absorbance of bixin in various solvents, with the exception of hexane, increased linearly with concentration. PMID:24840486

  19. Total mercury in the hair of children by combustion atomic absorption spectrometry (Comb-AAS).

    PubMed

    Díez, Sergi; Montuori, Paolo; Querol, Xavier; Bayona, Josep M

    2007-04-01

    A simple and rapid procedure for measuring total mercury in human hair was evaluated and compared with a conventional technique. An Advanced Mercury Analyzer (AMA-254) based on sample catalytic combustion, preconcentration by gold amalgamation, thermal desorption, and atomic absorption spectrometry (AAS) (Comb-AAS) was assessed for the direct determination of milligram quantities of human hair. Precision (% relative standard deviation) was < 7% and accuracy was determined by using two human hair reference materials (i.e., NIES No. 13 and IAEA-086) that were within the certified range. In comparison to conventional graphite-furnace atomic absorption spectrophotometry (GF-AAS), we found that our method obtained statistically equivalent results. Because total analysis time per sample was less than 10 min, the Comb-AAS method was in fact much faster than the GF-AAS method. In addition, Comb-AAS does not generate waste products and could be mainly useful for the analysis of a large amount of samples. Then, the authors suggest that this quick method could be useful for measuring mercury in human hair. Therefore, the mercury content in hair for a non-exposed group of children (n=40) living in Spain was evaluated. The mean and median hair mercury levels for the subjects under study were found to be lower than the value of 1 microg/g, corresponding to the reference dose of 0.1 microg of methylmercury per kilogram body weight set by the U.S. Environmental Protection Agency.

  20. Evidence for Photoionization-driven Broad Absorption Line Variability

    NASA Astrophysics Data System (ADS)

    Wang, Tinggui; Yang, Chenwei; Wang, Huiyuan; Ferland, Gary

    2015-12-01

    We present a qualitative analysis of the variability of quasar broad absorption lines using the large multi-epoch spectroscopic data set of the Sloan Digital Sky Survey Data Release 10. We confirm that variations of absorption lines are highly coordinated among different components of the same ion or the same absorption component of different ions for C iv, Si iv, and N v. Furthermore, we show that the equivalent widths (EWs) of the lines decrease or increase statistically when the continuum brightens or dims. This is further supported by the synchronized variations of emission and absorption-line EWs when the well-established intrinsic Baldwin effect for emission lines is taken into account. We find that the emergence of an absorption component is usually accompanied by the dimming of the continuum while the disappearance of an absorption-line component is accompanied by the brightening of the continuum. This suggests that the emergence or disappearance of a C iv absorption component is only the extreme case, when the ionic column density is very sensitive to continuum variations or the continuum variability the amplitude is larger. These results support the idea that absorption-line variability is driven mainly by changes in the gas ionization in response to continuum variations, that the line-absorbing gas is highly ionized, and in some extreme cases, too highly ionized to be detected in UV absorption lines. Due to uncertainties in the spectroscopic flux calibration, we cannot quantify the fraction of quasars with asynchronized continuum and absorption-line variations.

  1. Extraordinary absorption of sound in porous lamella-crystals

    PubMed Central

    Christensen, J.; Romero-García, V.; Picó, R.; Cebrecos, A.; de Abajo, F. J. García; Mortensen, N. A.; Willatzen, M.; Sánchez-Morcillo, V. J.

    2014-01-01

    We present the design of a structured material supporting complete absorption of sound with a broadband response and functional for any direction of incident radiation. The structure which is fabricated out of porous lamellas is arranged into a low-density crystal and backed by a reflecting support. Experimental measurements show that strong all-angle sound absorption with almost zero reflectance takes place for a frequency range exceeding two octaves. We demonstrate that lowering the crystal filling fraction increases the wave interaction time and is responsible for the enhancement of intrinsic material dissipation, making the system more absorptive with less material. PMID:24728322

  2. Interpretation of NO2 absorption in twilight sky spectra

    NASA Astrophysics Data System (ADS)

    McMahon, B. B.

    1984-07-01

    A multiple scattering model has been developed to calculate nitrogen dioxide (NO2) absorption in the light from the zenith sky during twilight. Model studies show that this absorption is not very sensitive to the atmospheric temperature profile or to tropospheric NO2. The model was used to interpret some ground-based measurements of NO2 sky absorption. Values for the total stratospheric column amount vary from 2 to 12 x 10 to the 15th molec/sq cm, and the mean altitude of the stratospheric concentration profile is around 35 km. These observations are in broad agreement with those of other workers.

  3. X-ray absorption and high redshift quasars

    NASA Technical Reports Server (NTRS)

    Elvis, Martin

    1996-01-01

    The low energy cut-offs toward radio-loud quasars with z greater than 2, red quasars, and broad absorption line quasars are discussed. The X-ray absorption seems to be common among different types of red shift quasar. The Rosat position sensitive proportional counter (PSPC) spectra of z = 3 quasars and of a red quasar are presented. Broad absorption lines show outflow velocities of up to 0.1 c to 0.2 c. The advantages and the disadvantages of high red shift observations are underlined.

  4. Flameless atomic-absorption determination of gold in geological materials

    USGS Publications Warehouse

    Meier, A.L.

    1980-01-01

    Gold in geologic material is dissolved using a solution of hydrobromic acid and bromine, extracted with methyl isobutyl ketone, and determined using an atomic-absorption spectrophotometer equipped with a graphite furnace atomizer. A comparison of results obtained by this flameless atomic-absorption method on U.S. Geological Survey reference rocks and geochemical samples with reported values and with results obtained by flame atomic-absorption shows that reasonable accuracy is achieved with improved precision. The sensitivity, accuracy, and precision of the method allows acquisition of data on the distribution of gold at or below its crustal abundance. ?? 1980.

  5. Microwave absorption properties of composite powders with low density

    NASA Astrophysics Data System (ADS)

    Mu, Guohong; Shen, Haigen; Qiu, Jianxun; Gu, Mingyuan

    2006-12-01

    The composites of barium ferrite coated on hollow ceramic microspheres were prepared using sol-gel technique. The crystal structure, morphology and microwave absorption properties of composite powders with different weight ratio of microspheres were studied with XRD, EDS, FESEM and vector network analyzer. The results show that the microwave absorption properties of composite powders are greatly improved. The maximum microwave loss of composite powders reaches 31 dB with an amount of 50 wt.% microspheres, and its density is only about 1.80 g/cm 3. The effect of hollow ceramic microspheres on the microwave absorption property is also discussed.

  6. Synthesis and nonlinear optical absorption of novel chalcone derivative compounds

    NASA Astrophysics Data System (ADS)

    Rahulan, K. Mani; Balamurugan, S.; Meena, K. S.; Yeap, G.-Y.; Kanakam, Charles C.

    2014-03-01

    3-(4-(dimethylamino)phenyl)-1-(4-(4-(hydroxymethyl)-1H-1,2,3-triazol-1-yl)phenyl)prop-2-en-1-one was synthesized and its third order nonlinear optical properties have been investigated using a z-scan technique with nanosecond laser pulses at 532 nm. The nonlinear absorption behavior of the compound in chloroform presents a distinct difference at different laser intensity. Interestingly, the compound showed a switchover from saturable absorption (SA) to reverse saturable absorption (RSA) with the increase of excitation intensity. Our studies suggest that compound could be used as a potential candidate for optical device applications such as optical limiters.

  7. Sound absorption in metallic foams

    NASA Astrophysics Data System (ADS)

    Lu, T. J.; Hess, Audrey; Ashby, M. F.

    1999-06-01

    The sound absorption capacity of one type of aluminum alloy foams—trade name Alporas—is studied experimentally. The foam in its as-received cast form contains closed porosities, and hence does not absorb sound well. To make the foam more transparent to air motion, techniques based on either rolling or hole drilling are used. Under rolling, the faces of some of the cells break to form small sharp-edged cracks as observed from a scanning electronic microscope. These cracks become passage ways for the in-and-out movement of air particles, resulting in sound absorption improvement. The best performance is nevertheless achieved via hole drilling where nearly all of the sound can be absorbed at selected frequencies. Combining rolling with hole drilling does not appear to lend additional benefits for sound absorption. Image analysis is carried out to characterize the changes in cell morphologies due to rolling/compression, and the drop in elastic modulus due to the formation of cracks is recorded. The effects of varying the relative foam density and panel thickness on sound absorption are measured, and optimal relative density and thickness of the panel are identified. Analytical models are used to explain the measured increase in sound absorption due to rolling and/or drilling. Sound absorbed by viscous flow across small cracks appears to dominate over that dissipated via other mechanisms.

  8. Chirality Dependence of the Absorption Cross Section of Carbon Nanotubes

    NASA Astrophysics Data System (ADS)

    Vialla, Fabien; Roquelet, Cyrielle; Langlois, Benjamin; Delport, Géraud; Santos, Silvia Morim; Deleporte, Emmanuelle; Roussignol, Philippe; Delalande, Claude; Voisin, Christophe; Lauret, Jean-Sébastien

    2013-09-01

    The variation of the optical absorption of carbon nanotubes with their geometry has been a long-standing question at the heart of both metrological and applicative issues, in particular because optical spectroscopy is one of the primary tools for the assessment of the chiral species abundance of samples. Here, we tackle the chirality dependence of the optical absorption with an original method involving ultraefficient energy transfer in porphyrin-nanotube compounds that allows uniform photoexcitation of all chiral species. We measure the absolute absorption cross section of a wide range of semiconducting nanotubes at their S22 transition and show that it varies by up to a factor of 2.2 with the chiral angle, with type I nanotubes showing a larger absorption. In contrast, the luminescence quantum yield remains almost constant.

  9. Laser-supported solid-state absorption fronts in silica

    NASA Astrophysics Data System (ADS)

    Carr, C. W.; Bude, J. D.; Demange, P.

    2010-11-01

    We develop a model based on simulation and extensive experimentation that explains the behavior of solid-state laser-supported absorption fronts generated in fused silica during high intensity (up to 5GW/cm2 ) laser exposure. Both experiments and simulations show that the absorption front velocity is constant in time and is nearly linear in laser intensity. Further, this model can explain the dependence of laser damage site size on these parameters. We show that these absorption fronts naturally result from the combination of high-temperature-activated deep subband-gap optical absorptivity, free-electron transport, and thermal diffusion in defect-free silica for temperatures up to 15000K and pressures <10GPa . The regime of parameter space critical to this problem spans and extends that measured by other means. It serves as a platform for understanding general laser-matter interactions in dielectrics under a variety of conditions.

  10. [Study on oral absorption enhancers of astragalus polysaccharides].

    PubMed

    Chen, Xiao-Yun; Tan, Xiao-Bin; Sun, E; Liu, Dan; Jia, Xiao-Bin; Zhang, Zhen-Hai

    2014-04-01

    Astragalus polysaccharides was lounded to 4-(2-aminoethylphenol), followed by labeling the APS-Tyr with fluorescein-5-isothiocyanate (FITC) at the secondary amino group. The absorption enhancement effects of low molecular weight chitosan and protamine on astragalus polysaccharides were evaluated via Caco-2 cell culture model. The results show that the fluorecent labeling compound has good stability and high sensitivity. On the other hand low molecular weight chitosan and protamine also can promoted absorption of the astragalus polysaccharides without any cytotoxity, and the absorption increase was more significant with increasing the amount of low molecular weight chitosan and protamine. At the same time, the low molecular weight chitosan has slightly better effect. The transepithelial electric resistance (TEER) of Caco-2 cells show that absorption enhancers could improve its membrane transport permeability by opening tight junctions between cells and increasing the cell membrane fluidity.

  11. Low level detection of Benzene in Food Grade Hexane by Ultraviolet Spectrophotometry.

    PubMed

    Emmandi, R; Sastry, M I S; Patel, M B

    2014-10-15

    A simple, sensitive, and accurate Ultraviolet Spectrophotometric method has been developed and validated for the determination of Benzene in Food Grade Hexane. Benzene in spectroscopic grade Hexane shows vibrational fine structure having four well resolved peaks. In the wavelength range 240-270nm, peak at 255nm is considered for the method development. Beer's law was obeyed in the concentration range of 0.6-10.0μLL(-1), with correlation coefficient, 0.9999, detection limit 0.2μLL(-1) and quantitation limit 0.6μLL(-1) are established. Percentage recovery studies showed that the method was not affected by the presence of other solvents having the similar boiling range with Hexane. The method was validated by determining its accuracy and precision which proves suitability of the developed method for the routine determination of Benzene in Food Grade Hexane. The proposed method has been applied successfully for the analysis of the Food Grade Hexane.

  12. Infrared spectrophotometry of Comet IRAS-Araki-Alcock (1983d) - A bare nucleus revealed?

    NASA Technical Reports Server (NTRS)

    Hanner, M. S.; Aitken, D. K.; Knacke, R.; Mccorkle, S.; Roche, P. F.; Tokunaga, A. T.

    1985-01-01

    Spectra of the central core and surrounding coma of Comet IRAS-Araki-Alcock (1983d) were obtained at 8-13 microns on May 11 and 2-4 microns on May 12, 1983. Spatially resolved measurements at 10 microns with a 4-arcsec beam showed that the central core was more than 100 times brighter than the inner coma only 8 arcsec away; for radially outflowing dust, the brightness ratio would be a factor of 8. The observations of the central core are consistent with direct detection of a nucleus having a radius of approximately 5 km. The temperature of the sunlit hemisphere was greater than 300 K. Spectra of the core are featureless, while spectra of the coma suggest weak silicate emission. The spectra show no evidence for icy grains. The dust production rate on May 11.4 was about 100,000 g/sec, assuming that the gas flux from the dust-producing areas on the nucleus was about 0.00001 g/sq cm per sec.

  13. THE STAR FORMATION HISTORY AND METAL CONTENT OF THE GREEN PEAS. NEW DETAILED GTC-OSIRIS SPECTROPHOTOMETRY OF THREE GALAXIES

    SciTech Connect

    Amorin, R.; Perez-Montero, E.; Vilchez, J. M.

    2012-04-20

    We present deep broadband imaging and long-slit spectroscopy of three compact, low-mass starburst galaxies at redshift z {approx} 0.2-0.3, also referred to as Green Peas (GP). We measure physical properties of the ionized gas and derive abundances for several species with high precision. We find that the three GPs display relatively low extinction, low oxygen abundances, and remarkably high nitrogen-to-oxygen ratios. We also report on the detection of clear signatures of Wolf-Rayet (W-R) stars in these galaxies. We carry out a pilot spectral synthesis study using a combination of both population and evolutionary synthesis models. Their outputs are in qualitative agreement, strongly suggesting a formation history dominated by starbursts. In agreement with the presence of W-R stars, these models show that these GPs currently undergo a major starburst producing between {approx}4% and {approx}20% of their stellar mass. However, as models imply, they are old galaxies that formed most of their stellar mass several Gyr ago. The presence of old stars has been spectroscopically verified in one of the galaxies by the detection of Mg I {lambda}{lambda}5167, 5173 absorption lines. Additionally, we perform a surface photometry study based on Hubble Space Telescope data, which indicates that the three galaxies possess an exponential low surface brightness envelope. If due to stellar emission, the latter is structurally compatible with the evolved hosts of luminous blue compact dwarf (BCD)/H II galaxies, suggesting that GPs are identifiable with major episodes in the assembly history of local BCDs. These conclusions highlight the importance of these objects as laboratories for studying galaxy evolution at late cosmic epochs.

  14. In Vitro Spectrophotometry of Tooth Discoloration Induced by Tooth-Colored Mineral Trioxide Aggregate and Calcium-Enriched Mixture Cement

    PubMed Central

    Arman, Marjan; Khalilak, Zohreh; Rajabi, Moones; Esnaashari, Ehsan; Saati, Keyvan

    2015-01-01

    Introduction: There are numerous factors that can lead to tooth discoloration after endodontic treatment, such as penetration of endodontic materials into the dentinal tubules during root canal treatment. The aim of this in vitro study was to compare discoloration induced by tooth colored mineral trioxide aggregate (MTA) and calcium-enriched mixture (CEM) cement in extracted human teeth. Methods and Materials: Thirty two dentin-enamel cuboid blocks (7×7×2 mm) were prepared from extracted maxillary central incisors. Standardized cavities were prepared in the middle of each cube, leaving 1 mm of enamel and dentin on the labial surface. The specimens were randomly divided into two study groups (n=12) and two positive and negative control groups (n=4). In either study groups the cavities were filled with MTA or CEM cement. The positive and negative control groups were filled with blood or left empty, respectively. The cavities were sealed with composite resin and stored in normal saline. Color measurement was carried out by spectrophotometry at different time intervals including before (T0), and 1 week (T1), 1 month (T2) and 6 months (T3) after placement of materials. Repeated-measures ANOVA was used to compare the discoloration between the groups; the material type was considered as the inter-subject factor. The level of significance was set at 0.05. Results: No significant differences were detected between the groups in all time intervals (P>0.05). Conclusion: Tooth discoloration was similarly detectable with both of the two experimental materials. PMID:26576163

  15. The influence of a clear layer on near-infrared spectrophotometry measurements using a liquid neonatal head phantom

    NASA Astrophysics Data System (ADS)

    Wolf, Martin; Keel, Matthias; Dietz, Vera; von Siebenthal, Kurt; Bucher, Hans Ulrich; Baenziger, Oskar

    1999-07-01

    It is difficult to test near-infrared spectrophotometry instruments in vivo. Therefore we constructed a liquid phantom which mimics the neonatal head. It consists of a spherical 3.5 mm thick layer of silicone rubber simulating skin and bone and a 0.5 mm thick clear layer of polypropylene imitating cerebrospinal fluid. It acts as container for a liquid solution with Intralipidreg, 60 µmol l-1 haemoglobin and yeast. The solution was oxygenated using oxygen and then deoxygenated by the yeast. From the instrumental (Critikon 2020) algorithm, we found that with increasing scattering (0.5%, 1%, 1.5% and 2% Intralipidreg concentration) the reading was increasingly offset from the expected value of 0 µmol l-1 by 55.7, 68.6, 76.5 and 80.4 µmol l-1 (oxyhaemoglobin) and 16.0, 24.4, 29.6 and 31.7 µmol l-1 (deoxyhaemoglobin). This reduced the range of the oxygen saturation reading from the expected 100% to 31.5, 21.1, 14.3 and 11.5%. Haemoglobin concentration changes were increasingly underestimated by a factor of two to four. For a second algorithm based on the diffusion approximation the offsets were smaller: oxyhaemoglobin 11.4, 17.8, 22.5 and 25.1 µmol l-1 and deoxyhaemoglobin 1.3, 3.4, 5.2 and 6.0 µmol l-1. The range of the oxygen saturation reading was higher: 41.3, 29.2, 23.4 and 16.6%. Concentration changes were underestimated by a factor of six to ten. This study demonstrates the need to develop algorithms which take into consideration anatomical structures.

  16. Acid-Base Titration of (S)-Aspartic Acid: A Circular Dichroism Spectrophotometry Experiment

    NASA Astrophysics Data System (ADS)

    Cavaleiro, Ana M. V.; Pedrosa de Jesus, Júlio D.

    2000-09-01

    The magnitude of the circular dichroism of (S)-aspartic acid in aqueous solutions at a fixed wavelength varies with the addition of strong base. This laboratory experiment consists of the circular dichroism spectrophotometric acid-base titration of (S)-aspartic acid in dilute aqueous solutions, and the use of the resulting data to determine the ionization constant of the protonated amino group. The work familiarizes students with circular dichroism and illustrates the possibility of performing titrations using a less usual instrumental method of following the course of a reaction. It shows the use of a chiroptical property in the determination of the concentration in solution of an optically active molecule, and exemplifies the use of a spectrophotometric titration in the determination of an ionization constant.

  17. Spectrophotometry of prominences in the phase preceding decay. [line spectra and spectral emission

    NASA Technical Reports Server (NTRS)

    Rakhubovskiy, A. S.

    1974-01-01

    The results are presented of spectrophotometric processing of prominence spectra in both the quiet and the decay phases. A catalog was compiled of equivalent widths, central intensities, Doppler half-widths, and half-widths of emission lines. The reduced Doppler half-widths of D3 and of the H, K Ca(+) lines obtained in a prominence active phase are much larger than those obtained during a quiet phase. Comparison of the equivalent widths and central intensities of H sub alpha, H sub beta hydrogen and D3 helium lines shows that the values increase in the active phase for the D3 lines and decrease for the H sub alpha, H sub beta lines.

  18. Near-simultaneous ultraviolet and optical spectrophotometry of T Tauri stars

    NASA Technical Reports Server (NTRS)

    Goodrich, Robert W.; Herbig, G. H.

    1986-01-01

    A set of near-simultaneous ultraviolet and optical spectra and UBVR(J)I(J) photometry of five T Tauri stars has been analyzed for the shape of the energy distribution shortward of 3000 A. The far-ultraviolet continua of these stars are very much stronger than the level of light scattered from longer wavelengths in the IUE spectrograph. The results, expressed as two-color plots, show that the UV colors of T Tauri stars differ significantly from those expected from their optical spectral types. Although these particular K-type T Tauri stars are not extreme members of the class, they have the UV colors of A stars. The spectral shape of this UV excess is approximately that expected from published chromospheric models of T Tauri stars.

  19. Radiation Emission and Re-Absorption Mechanisms in Dense Mediums

    NASA Astrophysics Data System (ADS)

    Mahdavi, M.; Ghazizadeh, S. F.

    2012-09-01

    In this paper, the Bremsstrahlung emission and re-absorption mechanisms are studied mainly through Inverse Bremsstrahlung and Compton Scattering. The Radiation Specific Power is calculated numerically assuming the suitable forms of Energy Distribution Function in plasma conditions. The calculation of Spectral Emission shows that, the Bremsstrahlung emission is strongly forward and backward peak relative to electron direction in overdense and high temperature plasma. Finally, some of the conditions for dominant of the re-absorption mechanism are explained.

  20. Absorption and Direct Processes in Chaotic Wave Scattering

    SciTech Connect

    Mendez-Sanchez, R. A.; Baez, G.; Martinez-Mares, M.

    2010-12-21

    Recent results on the scattering of waves by chaotic systems with losses and direct processes are discussed. We start by showing the results without direct processes nor absorption. We then discuss systems with direct processes and lossy systems separately. Finally the discussion of systems with both direct processes and loses is given. We will see how the regimes of strong and weak absorption are modified by the presence of the direct processes.

  1. Percutaneous absorption of chlorhexidine in neonatal cord care.

    PubMed Central

    Aggett, P J; Cooper, L V; Ellis, S H; McAinsh, J

    1981-01-01

    The percutaneous absorption of chlorhexidine during its routine use in topical antiseptic preparations used in umbilical cord care was investigated by determining plasma chlorhexidine concentrations at ages 5 and 9 days. These showed that percutaneous absorption of chlorhexidine occurred in preterm neonates treated with a 1% solution of chlorhexidine in ethanol, but not in term infants similarly treated, or in preterm infants treated only with a dusting powder containing 1% chlorhexidine and 3% zinc oxide. PMID:7305432

  2. Enhanced absorption cycle computer model

    NASA Astrophysics Data System (ADS)

    Grossman, G.; Wilk, M.

    1993-09-01

    Absorption heat pumps have received renewed and increasing attention in the past two decades. The rising cost of electricity has made the particular features of this heat-powered cycle attractive for both residential and industrial applications. Solar-powered absorption chillers, gas-fired domestic heat pumps, and waste-heat-powered industrial temperature boosters are a few of the applications recently subjected to intensive research and development. The absorption heat pump research community has begun to search for both advanced cycles in various multistage configurations and new working fluid combinations with potential for enhanced performance and reliability. The development of working absorption systems has created a need for reliable and effective system simulations. A computer code has been developed for simulation of absorption systems at steady state in a flexible and modular form, making it possible to investigate various cycle configurations with different working fluids. The code is based on unit subroutines containing the governing equations for the system's components and property subroutines containing thermodynamic properties of the working fluids. The user conveys to the computer an image of his cycle by specifying the different subunits and their interconnections. Based on this information, the program calculates the temperature, flow rate, concentration, pressure, and vapor fraction at each state point in the system, and the heat duty at each unit, from which the coefficient of performance (COP) may be determined. This report describes the code and its operation, including improvements introduced into the present version. Simulation results are described for LiBr-H2O triple-effect cycles, LiCl-H2O solar-powered open absorption cycles, and NH3-H2O single-effect and generator-absorber heat exchange cycles. An appendix contains the user's manual.

  3. SPECTROPHOTOMETRY OF THE PERIODIC ACID-SCHIFF REACTION WITH PITUITARY HORMONES IN VITRO AND IN HISTOLOGICAL SECTIONS

    PubMed Central

    Fand, Sally B.; Thorell, Bo

    1962-01-01

    The spectral light absorption of the in vitro periodic acid-Schiff reactions of 4 purified pituitary hormones is described. The absorption spectra present a maximum between 560 and 565 mµ. The color developed conforms with Beer's law for the ranges of concentration examined. The different hormones exhibit different chromogenicity per unit of biological activity: the color produced by 1 unit of FSH is equivalent to approximately 2 of TSH, 4 of LH, and 30 of ACTH. Microspectrophotometric measurements of the PAS-positive structures in histological sections of the human pituitary give absorption curves with shapes similar to those obtained in vitro, although quantitative differences exist. It is concluded that under the proper experimental conditions microspectra of the pituitary structures might, in the future, prove to give a quantitative measure of aldehyde groups generated from glycoprotein tropins by periodate oxidation. PMID:13891517

  4. Breaking temporal symmetries for emission and absorption

    PubMed Central

    Hadad, Yakir; Soric, Jason C.; Alu, Andrea

    2016-01-01

    Time-reversal symmetries impose stringent constraints on emission and absorption. Antennas, from radiofrequencies to optics, are bound to transmit and receive signals equally well from the same direction, making a directive antenna prone to receive echoes and reflections. Similarly, in thermodynamics Kirchhoff’s law dictates that the absorptivity and emissivity are bound to be equal in reciprocal systems at equilibrium, e(ω,θ)=a(ω,θ), with important consequences for thermal management and energy applications. This bound requires that a good absorber emits a portion of the absorbed energy back to the source, limiting its overall efficiency. Recent works have shown that weak time modulation or mechanical motion in suitably designed structures may largely break reciprocity and time-reversal symmetry. Here we show theoretically and experimentally that a spatiotemporally modulated device can be designed to have drastically different emission and absorption properties. The proposed concept may provide significant advances for compact and efficient radiofrequency communication systems, as well as for energy harvesting and thermal management when translated to infrared frequencies. PMID:26984502

  5. Breaking temporal symmetries for emission and absorption

    NASA Astrophysics Data System (ADS)

    Hadad, Yakir; Soric, Jason C.; Alu, Andrea

    2016-03-01

    Time-reversal symmetries impose stringent constraints on emission and absorption. Antennas, from radiofrequencies to optics, are bound to transmit and receive signals equally well from the same direction, making a directive antenna prone to receive echoes and reflections. Similarly, in thermodynamics Kirchhoff's law dictates that the absorptivity and emissivity are bound to be equal in reciprocal systems at equilibrium, e(ω,θ)=a(ω,θ), with important consequences for thermal management and energy applications. This bound requires that a good absorber emits a portion of the absorbed energy back to the source, limiting its overall efficiency. Recent works have shown that weak time modulation or mechanical motion in suitably designed structures may largely break reciprocity and time-reversal symmetry. Here we show theoretically and experimentally that a spatiotemporally modulated device can be designed to have drastically different emission and absorption properties. The proposed concept may provide significant advances for compact and efficient radiofrequency communication systems, as well as for energy harvesting and thermal management when translated to infrared frequencies.

  6. Breaking temporal symmetries for emission and absorption.

    PubMed

    Hadad, Yakir; Soric, Jason C; Alu, Andrea

    2016-03-29

    Time-reversal symmetries impose stringent constraints on emission and absorption. Antennas, from radiofrequencies to optics, are bound to transmit and receive signals equally well from the same direction, making a directive antenna prone to receive echoes and reflections. Similarly, in thermodynamics Kirchhoff's law dictates that the absorptivity and emissivity are bound to be equal in reciprocal systems at equilibrium, e(ω, θ)=a(ω, θ), with important consequences for thermal management and energy applications. This bound requires that a good absorber emits a portion of the absorbed energy back to the source, limiting its overall efficiency. Recent works have shown that weak time modulation or mechanical motion in suitably designed structures may largely break reciprocity and time-reversal symmetry. Here we show theoretically and experimentally that a spatiotemporally modulated device can be designed to have drastically different emission and absorption properties. The proposed concept may provide significant advances for compact and efficient radiofrequency communication systems, as well as for energy harvesting and thermal management when translated to infrared frequencies. PMID:26984502

  7. Absorption-heat-pump system

    DOEpatents

    Grossman, G.; Perez-Blanco, H.

    1983-06-16

    An improvement in an absorption heat pump cycle is obtained by adding adiabatic absorption and desorption steps to the absorber and desorber of the system. The adiabatic processes make it possible to obtain the highest temperature in the absorber before any heat is removed from it and the lowest temperature in the desorber before heat is added to it, allowing for efficient utilization of the thermodynamic availability of the heat supply stream. The improved system can operate with a larger difference between high and low working fluid concentrations, less circulation losses, and more efficient heat exchange than a conventional system.

  8. Diabetic lipohypertrophy delays insulin absorption.

    PubMed

    Young, R J; Hannan, W J; Frier, B M; Steel, J M; Duncan, L J

    1984-01-01

    The effect of lipohypertrophy at injection sites on insulin absorption has been studied in 12 insulin-dependent diabetic patients. The clearance of 125I-insulin from sites with lipohypertrophy was significantly slower than from complementary nonhypertrophied sites (% clearance in 3 h, 43.8 +/- 3.5 +/- SEM) control; 35.3 +/- 3.9 lipohypertrophy, P less than 0.05). The degree of the effect was variable but sufficient in several patients to be of clinical importance. Injection-site lipohypertrophy is another factor that modifies the absorption of subcutaneously injected insulin.

  9. Solar powered absorption air conditioning

    NASA Astrophysics Data System (ADS)

    Vardon, J. M.

    1980-04-01

    Artificial means of providing or removing heat from the building are discussed along with the problem of the appropriate building design and construction for a suitable heat climate inside the building. The use of a lithium bromide-water absorption chiller, powered by a hot water store heated by an array of stationary flat collectors, is analyzed. An iterative method of predicting the cooling output from a LiBr-water absorption refrigeration plant having variable heat input is described and a model allowing investigation of the performance of a solar collector and thermal storage system is developed.

  10. Geomorphology and spectrophotometry of Philae's landing site on comet 67P/Churyumov-Gerasimenko

    NASA Astrophysics Data System (ADS)

    La Forgia, F.; Giacomini, L.; Lazzarin, M.; Massironi, M.; Oklay, N.; Scholten, F.; Pajola, M.; Bertini, I.; Cremonese, G.; Barbieri, C.; Naletto, G.; Simioni, E.; Preusker, F.; Thomas, N.; Sierks, H.; Lamy, P.; Rodrigo, R.; Koschny, D.; Rickman, H.; Keller, H. U.; Agarwal, J.; Auger, A.-T.; A'Hearn, M. F.; Barucci, M. A.; Bertaux, J.-L.; Besse, S.; Bodewits, D.; Da Deppo, V.; Davidsson, B.; Debei, S.; De Cecco, M.; El-Maarry, M. R.; Ferri, F.; Fornasier, S.; Fulle, M.; Groussin, O.; Gutiérrez, P. J.; Güttler, C.; Hall, I.; Hviid, S. F.; Ip, W.-H.; Jorda, L.; Knollenberg, J.; Kramm, J. R.; Kührt, E.; Küppers, M.; Lara, L.-M.; Lopez Moreno, J. J.; Magrin, S.; Marzari, F.; Michalik, H.; Mottola, S.; Pommerol, A.; Tubiana, C.; Vincent, J.-B.

    2015-11-01

    Context. On 12 November 2014 the European mission Rosetta succeeded in delivering a lander, named Philae, on the surface of one of the smallest, low-gravity and most primitive bodies of the solar system, the comet 67P/Churyumov-Gerasimenko (67P). Aims: The aim of this paper is to provide a comprehensive geomorphological and spectrophotometric analysis of Philae's landing site (Agilkia) to give an essential framework for the interpretation of its in situ measurements. Methods: OSIRIS images, coupled with gravitational slopes derived from the 3D shape model based on stereo-photogrammetry were used to interpret the geomorphology of the site. We adopted the Hapke model, using previously derived parameters, to photometrically correct the images in orange filter (649.2 nm). The best approximation to the Hapke model, given by the Akimov parameter-less function, was used to correct the reflectance for the effects of viewing and illumination conditions in the other filters. Spectral analyses on coregistered color cubes were used to retrieve spectrophotometric properties. Results: The landing site shows an average normal albedo of 6.7% in the orange filter with variations of ~15% and a global featureless spectrum with an average red spectral slope of 15.2%/100 nm between 480.7 nm (blue filter) and 882.1 nm (near-IR filter). The spatial analysis shows a well-established correlation between the geomorphological units and the photometric characteristics of the surface. In particular, smooth deposits have the highest reflectance a bluer spectrum than the outcropping material across the area. Conclusions: The featureless spectrum and the redness of the material are compatible with the results by other instruments that have suggested an organic composition. The observed small spectral variegation could be due to grain size effects. However, the combination of photometric and spectral variegation suggests that a compositional differentiation is more likely. This might be

  11. Aswan site on comet 67P/Churyumov-Gerasimenko: Morphology, boulder evolution, and spectrophotometry

    NASA Astrophysics Data System (ADS)

    Pajola, Maurizio; Oklay, Nilda; La Forgia, Fiorangela; Giacomini, Lorenza; Massironi, Matteo; Bertini, Ivano; El-Maarry, M. R.; Marzari, Francesco; Preusker, Frank; Scholten, Frank; Höfner, Sebastian; Lee, Jui-Chi; Vincent, Jean-Baptiste; Groussin, Olivier; Naletto, Giampiero; Lazzarin, Monica; Barbieri, Cesare; Sierks, Holger; Lamy, Philippe; Rodrigo, Rafael; Koschny, Detlef; Rickman, Hans; Keller, Horst U.; Agarwal, Jessica; A'Hearn, Michael F.; Barucci, Maria A.; Bertaux, Jean-Loup; Cremonese, Gabriele; Da Deppo, Vania; Davidsson, Björn; De Cecco, Mariolino; Debei, Stefano; Ferri, Francesca; Fornasier, Sonia; Fulle, Marco; Güttler, Carsten; Gutierrez, Pedro J.; Hviid, Stubbe F.; Ip, Wing-Huen; Jorda, Laurent; Knollenberg, Jörg; Kramm, J.-Rainer; Küppers, Michael; Kürt, Ekkehard; Lara, Luisa M.; Lin, Zhong-Yi; Lopez Moreno, Jose J.; Magrin, Sara; Michalik, Harald; Mottola, Stefano; Thomas, Nicholas; Tubiana, Cecilia

    2016-07-01

    Aims: We provide a detailed morphological analysis of the Aswan site on comet 67P/Churyumov-Gerasimenko (67P). We derive the size-frequency distribution of boulders ≥2 m and correlate this distribution with the gravitational slopes for the first time on a comet. We perform the spectral analysis of this region to understand if possible surface variegation is related to thedifferent surface textures observable on the different units. Methods: We used two OSIRIS Narrow Angle Camera (NAC) image data sets acquired on September 19 and 22, 2014, with a scale of 0.5 m/px. Gravitational slopes derived from the 3D shape model of 67P were used to identify and interpret the different units of the site. By means of the high-resolution NAC data sets, boulders ≥2.0 m can be unambiguously identified and extracted using the software ArcGIS. Coregistered and photometrically corrected color cubes were used to perform the spectral analyses, and we retrieved the spectral properties of the Aswan units. Results: The high-resolution morphological map of the Aswan site (0.68 km2) shows that this site is characterized by four different units: fine-particle deposits located on layered terrains, gravitational accumulation deposits, taluses, and the outcropping layered terrain. Multiple lineaments are identified on the Aswan cliff, such as fractures, exposed layered outcrops, niches, and terraces. Close to the terrace margin, several arched features observed in plan view suggest that the margin progressively retreats as a result of erosion. The size-frequency of boulders ≥2 m in the entire study area has a power-law index of -3.9 +0.2/-0.3 (1499 boulders ≥2 m/km2), suggesting that the Aswan site is mainly dominated by gravitational events triggered by sublimation and/or thermal insolation weathering causing regressive erosion. The boulder size-frequency distribution versus gravitational slopes indicates that when higher gravitational slope terrains are considered, only boulders ≤10 m

  12. Balloon-borne far-infrared spectrophotometry of the galactic center region

    NASA Astrophysics Data System (ADS)

    Drapatz, S.; Haser, L.; Hofmann, R.; Oda, N.; Wilczek, R.

    Far-infrared observations of the galactic center have been carried through with the MPE 1m balloon-borne telescope "Golden Dragon". The measurements are composed of photometric scanning (33 - 95 μm) of the inner 4arcmin×4arcmin and low resolution spectroscopy (Δν = 10 cm-1) of the center and of a position approximately 1.5arcmin to the north. A Mars spectrum has been obtained for calibration. The spatial resolution of the photometry map is increased using the Maximum Entropy Method and the resulting map is compared to other observations in the same and other spectral regions. A clear asymmetry in the ring-like structure around the center indicates the presence of noncircular motions. The shape of the spectra is fairly smooth with at least no prominent dust features. A simple modelling shows a drastic increase of column density within 2 pc from the center and a modest drop over the next 3 pc to the north.

  13. Study of the most frequent natural tooth colors in the Spanish population using spectrophotometry

    PubMed Central

    2015-01-01

    PURPOSE To identify the most frequent natural tooth colors using the Easyshade Compact (Vita -Zahnfabrik) spectrophotometer on a sample of the Spanish population according to the 3D Master System. MATERIALS AND METHODS The middle third of the facial surface of natural maxillary central incisors was measured with an Easyshade Compact spectrophotometer (Vita Zahnfabrik) in 1361 Caucasian Spanish participants aged between 16 and 89 years. Natural tooth color was recorded using the 3D Master System nomenclature. The program used for the present descriptive statistical analysis of the results was SAS 9.1.3. RESULTS The results show that the most frequent dental color in the total sample studied is 3M1 (7.05%), followed by the intermediate shade 1M1.5 (6.91%) and 2L1.5 (6.02%). CONCLUSION According to the research methodology used, and taking into account the limitations of this study, it can be proposed that the most frequent color among the Spanish population is 3M1; the most common lightness group is 2; the most frequent hue group according to the 3D Master System is M and the most frequent chroma group is 1.5. PMID:26816571

  14. Spitzer and HST transit spectrophotometry of the exoplanet HD189733b

    NASA Astrophysics Data System (ADS)

    Désert, J.-M.; Sing, D. K.; Vidal-Madjar, A.; Lecavelier Des Etangs, A.; Hébrard, G.; Ehrenreich, D.; Ferlet, R.; Parmentier, V.; Henry, G.

    2009-11-01

    Transit observations in the infrared allow the atmospheric content of exoplanets to be determined. Here we present new primary transit observations of the hot-jupiter HD189733b, obtained in the near and mid-IR with Hubble and Spitzer Space Telescopes. The high-S/N photometric transit light curves allow us to improve the precision of the near infrared planet radius. We are able to derive accurate system parameters, including planet-to-star radius ratios, impact parameter, scale of the system, and central time of the transit from fits to the transit light curves. We compare the results obtained here with transmission spectroscopic models and with results from various other observations of this planet. These new observations show that water vapour bandheads are not detected using transmission photometry observations at either 1.6 μm or 3.6 μm. Our results further support that another species must absorb at these wavelengths, at high altitudes, and could be attributed to Rayleigh scattering by haze. Observations at 4.5 μm can also be interpreted as due to the presence of CO and would lead to a large CO/H2O ratio estimated to be between 1 and 60.

  15. Characterization of chromophoric dissolved organic matter (CDOM) in rainwater using fluorescence spectrophotometry.

    PubMed

    Salve, P R; Lohkare, H; Gobre, T; Bodhe, G; Krupadam, R J; Ramteke, D S; Wate, S R

    2012-02-01

    The fluorescence excitation-emission matrix of Chromophoric dissolved organic matter (CDOM) samples from rainwater collected at Rameswaram, Tamilnadu, India are analysed. Total five peaks were observed for humic/marine and protein likes substances respectively. The peak A and C intensities varies form 1.98 ± 0.28 and 0.97 ± 0.11 QSU respectively represents humic like substances. The peak B and T intensities varies from 3.94 ± 0.75 and 7.42 ± 1.43 QSU showed association of protein like substances whereas peak M intensities varies from 1.92 ± 0.37 QSU indicates marine contribution. Among the fluorophores, the following sequence were observed as T > B > A > M > C which indicates dominance of Tryptophan like substances in rainwater. The average peak T/C ratios was observed as 7.88 ± 2.2 indicates microbial contamination by Tryptophan-like substances with the high biological activity and low volatility.

  16. A pilot study of a new spectrophotometry device to measure tissue oxygen saturation.

    PubMed

    Abel, Gemma; Allen, John; Drinnan, Michael

    2014-09-01

    Tissue oxygen saturation (SO2) measurements have the potential for far wider use than at present but are limited by device availability and portability for many potential applications. A device based on a small, low-cost general-purpose spectrophotometer (the Harrison device) might facilitate wider use. The aim of this study was to compare the Harrison device with a commercial instrument, the LEA O2C.Measurements were carried out on the forearm and finger of 20 healthy volunteers, using a blood pressure cuff on the upper arm to induce different levels of oxygenation. Repeatability of both devices was assessed, and the Bland-Altman method was used to assess agreement between them.The devices showed agreement in overall tracking of changes in SO2. Test-retest agreement for the Harrison device was worse than for O2C, with SD repeatability of 10.6% (forearm) or 18.6% (finger). There was no overall bias between devices, but mean (SD) difference of 1.2 (11.8%) (forearm) or 4.4 (11.5%) (finger) were outside of a clinically acceptable range.Disagreements were attributed to the stability of the Harrison probe and the natural SO2 variations across the skin surface increasing the random error. Therefore, though not equivalent to the LEA O2C, a probe redesign and averaged measurements may help establish the Harrison device as a low cost alternative.

  17. Harnessing the electromagnetic absorptions of metamaterials for positive applications

    NASA Astrophysics Data System (ADS)

    Xiang, Yuanjiang; Zou, Yanhong; Luo, Hailu; Dai, Xiaoyu; Wen, Shuangchun; Fan, Dianyuan

    2010-08-01

    Absorption or loss is inevitable for the metal-based metamaterials (MMs) due to the intrinsic loss of the metal, and constitutes a major hurdle to the practical realization of most applications such as a sub-wavelength lens. Thus, to reduce the losses becomes one of the major challenges in the MM field. However, the inevitable loss can also be harnessed to take a positive role in the applications of MMs such as stealth technology or other types of cloaking devices. In this presentation, after a brief review of the advances in MMs-based absorbers, we present several schemes to fulfill the desired electromagnetic absorption properties, both linear and nonlinear. For linear absorption, we have experimentally demonstrated that the absorption performance of an ordinary microwave absorbing material can be evidently improved by using the electric resonance resulting from an array of subwavelength metallic circuit elements. For nonlinear absorption, we show theoretically that the active linear magnetic permeability induces a nonlinear absorption, similar to the two-photon absorption (TPA), of electric field in a lossy MM with a Kerr-type nonlinear polarization.

  18. Bicarbonate secretion and solute absorption in forestomach of the llama.

    PubMed

    Rübsamen, K; Engelhardt, W V

    1978-07-01

    Bicarbonate appearance in the lumen and its relationship to solute absorption were studied in a Pavlov pouch in the cardiac region of the first compartment of the llama forestomach. HCO3- appearance showed no diurnal variation. HCO3- accumulation was highly dependent on the pH of the solution used. The HCO3- ion probably is formed from CO2 diffusing into the lumen from the serosal side, as a result of cell metabolism and of OH- ions. HCO3- accumulation was closely related to volatile fatty acid (VFA) absorption. The ratio of HCO3- appearance to VFA absorption depended on the pH of the solution. At a pH of 6.6, about 0.1 mol HCO3- and, at a pH of 7.8, 0.9 mol HCO3- appeared per mole absorbed VFA, indicating that at slightly alkaline pH nearly all H+ ions required for the nonionic absorption of VFA appeared to be delivered from the dissociation of H2CO3. Bicarbonate gain and VFA absorption were increased when animals were not fed for 48 h. Sodium absorption was related to VFA as well as water absorption. PMID:677305

  19. On the nature of absorption features toward nearby stars

    NASA Astrophysics Data System (ADS)

    Kohl, S.; Czesla, S.; Schmitt, J. H. M. M.

    2016-06-01

    Context. Diffuse interstellar absorption bands (DIBs) of largely unknown chemical origin are regularly observed primarily in distant early-type stars. More recently, detections in nearby late-type stars have also been claimed. These stars' spectra are dominated by stellar absorption lines. Specifically, strong interstellar atomic and DIB absorption has been reported in τ Boo. Aims: We test these claims by studying the strength of interstellar absorption in high-resolution TIGRE spectra of the nearby stars τ Boo, HD 33608, and α CrB. Methods: We focus our analysis on a strong DIB located at 5780.61 Å and on the absorption of interstellar Na. First, we carry out a differential analysis by comparing the spectra of the highly similar F-stars, τ Boo and HD 33608, whose light, however, samples different lines of sight. To obtain absolute values for the DIB absorption, we compare the observed spectra of τ Boo, HD 33608, and α CrB to PHOENIX models and carry out basic spectral modeling based on Voigt line profiles. Results: The intercomparison between τ Boo and HD 33608 reveals that the difference in the line depth is 6.85 ± 1.48 mÅ at the DIB location which is, however, unlikely to be caused by DIB absorption. The comparison between PHOENIX models and observed spectra yields an upper limit of 34.0 ± 0.3 mÅ for any additional interstellar absorption in τ Boo; similar results are obtained for HD 33608 and α CrB. For all objects we derive unrealistically large values for the radial velocity of any presumed interstellar clouds. In τ Boo we find Na D absorption with an equivalent width of 0.65 ± 0.07 mÅ and 2.3 ± 0.1 mÅ in the D2 and D1 lines. For the other Na, absorption of the same magnitude could only be detected in the D2 line. Our comparisons between model and data show that the interstellar absorption toward τ Boo is not abnormally high. Conclusions: We find no significant DIB absorption in any of our target stars. Any differences between modeled and

  20. Aerosol Absorption Measurements in MILAGRO.

    NASA Astrophysics Data System (ADS)

    Gaffney, J. S.; Marley, N. A.; Arnott, W. P.; Paredes-Miranda, L.; Barnard, J. C.

    2007-12-01

    During the month of March 2006, a number of instruments were used to determine the absorption characteristics of aerosols found in the Mexico City Megacity and nearby Valley of Mexico. These measurements were taken as part of the Department of Energy's Megacity Aerosol Experiment - Mexico City (MAX-Mex) that was carried out in collaboration with the Megacity Interactions: Local and Global Research Observations (MILAGRO) campaign. MILAGRO was a joint effort between the DOE, NSF, NASA, and Mexican agencies aimed at understanding the impacts of a megacity on the urban and regional scale. A super-site was operated at the Instituto Mexicano de Petroleo in Mexico City (designated T-0) and at the Universidad Technologica de Tecamac (designated T-1) that was located about 35 km to the north east of the T-0 site in the State of Mexico. A third site was located at a private rancho in the State of Hidalgo approximately another 35 km to the northeast (designated T-2). Aerosol absorption measurements were taken in real time using a number of instruments at the T-0 and T-1 sites. These included a seven wavelength aethalometer, a multi-angle absorption photometer (MAAP), and a photo-acoustic spectrometer. Aerosol absorption was also derived from spectral radiometers including a multi-filter rotating band spectral radiometer (MFRSR). The results clearly indicate that there is significant aerosol absorption by the aerosols in the Mexico City megacity region. The absorption can lead to single scattering albedo reduction leading to values below 0.5 under some circumstances. The absorption is also found to deviate from that expected for a "well-behaved" soot anticipated from diesel engine emissions, i.e. from a simple 1/lambda wavelength dependence for absorption. Indeed, enhanced absorption is seen in the region of 300-450 nm in many cases, particularly in the afternoon periods indicating that secondary organic aerosols are contributing to the aerosol absorption. This is likely due