Science.gov

Sample records for ac magnetic permeability

  1. Saturated High Permeability Magnetic Shields

    NASA Astrophysics Data System (ADS)

    Trenkel, Christian

    2016-05-01

    High permeability magnetic shields can be used in space to mitigate the effect of magnetic sources by several orders of magnitude. Nevertheless, the presence of significant amounts of ferromagnetic material on-board a spacecraft carries, by itself, a certain risk in terms of meeting magnetic cleanliness requirements. One possibility is that the shield is accidentally magnetised irreversibly, either by a strong external field, or mechanical shock. A second possibility is that the shield will acquire an induced moment in the presence of external fields (DC or AC), and could potentially amplify them.Here, we propose the use of high permeability shields which are driven into their fully saturated state - by the source that is being shielded. This approach limits the shielding effect to perhaps one or two orders of magnitude, but is expected to mitigate the above risks substantially. We present extensive numerical simulations describing the design principle behind optimised, fully saturated shields, as well as some results to substantiate the above claims.

  2. AC photovoltaic module magnetic fields

    SciTech Connect

    Jennings, C.; Chang, G.J.; Reyes, A.B.; Whitaker, C.M.

    1997-12-31

    Implementation of alternating current (AC) photovoltaic (PV) modules, particularly for distributed applications such as PV rooftops and facades, may be slowed by public concern about electric and magnetic fields (EMF). This paper documents magnetic field measurements on an AC PV module, complementing EMF research on direct-current PV modules conducted by PG and E in 1993. Although not comprehensive, the PV EMF data indicate that 60 Hz magnetic fields (the EMF type of greatest public concern) from PV modules are comparable to, or significantly less than, those from household appliances. Given the present EMF research knowledge, AC PV module EMF may not merit considerable concern.

  3. Ac Permeability Measurement for Inter- and Intragrain Critical Current Densities in Oxide Superconductors

    NASA Astrophysics Data System (ADS)

    Matsushita, Teruo; Ni, Baorong

    1989-03-01

    A simple measuring method to discriminate between inter- and intragrain current densities in oxide superconductors under given magnetic fields and temperatures is proposed. This is a measurement of the imaginary part of the ac permeability or susceptibility as a function of the ac field amplitude. In this method, the analysis used to derive the penetration depth of the ac field in Campbell’s method or the waveform analysis method is not necessary. This method is useful when the value of the penetration field into the grains and that into the bulk specimen are remarkably different.

  4. Effect of the magnetic material on AC losses in HTS conductors in AC magnetic field carrying AC transport current

    NASA Astrophysics Data System (ADS)

    Wan, Xing-Xing; Huang, Chen-Guang; Yong, Hua-Dong; Zhou, You-He

    2015-11-01

    This paper presents an investigation on the AC losses in several typical superconducting composite conductors using the H-formulation model. A single superconducting strip with ferromagnetic substrate or cores and a stack of coated conductors with ferromagnetic substrates are studied. We consider all the coated conductors carrying AC transport currents and simultaneously exposed to perpendicular AC magnetic fields. The influences of the amplitude, frequency, phase difference and ferromagnetic materials on the AC losses are investigated. The results show that the magnetization losses of single strip and stacked strips have similar characteristics. The ferromagnetic substrate can increase the magnetization loss at low magnetic field, and decrease the loss at high magnetic field. The ferromagnetic substrate can obviously increase the transport loss in stacked strips. The trends of total AC losses of single strip and stacked strips are similar when they are carrying current or exposed to a perpendicular magnetic field. The effect of the frequency on the total AC losses of single strip is related to the amplitude of magnetic field. The AC losses decrease with increasing frequency in low magnetic field region while increase in high magnetic field region. As the phase difference changes, there is a periodic variation for the AC losses. Moreover, when the strip is under only the transport current and magnetic field, the ferromagnetic cores will increase the AC losses for large transport current or field.

  5. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  6. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  7. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  8. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  9. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  10. Size- and composition-dependent radio frequency magnetic permeability of iron oxide nanocrystals.

    PubMed

    Yun, Hongseok; Liu, Xiyu; Paik, Taejong; Palanisamy, Duraivelan; Kim, Jungkwun; Vogel, William D; Viescas, Arthur J; Chen, Jun; Papaefthymiou, Georgia C; Kikkawa, James M; Allen, Mark G; Murray, Christopher B

    2014-12-23

    We investigate the size- and composition-dependent ac magnetic permeability of superparamagnetic iron oxide nanocrystals for radio frequency (RF) applications. The nanocrystals are obtained through high-temperature decomposition synthesis, and their stoichiometry is determined by Mössbauer spectroscopy. Two sets of oxides are studied: (a) as-synthesized magnetite-rich and (b) aged maghemite nanocrystals. All nanocrystalline samples are confirmed to be in the superparamagnetic state at room temperature by SQUID magnetometry. Through the one-turn inductor method, the ac magnetic properties of the nanocrystalline oxides are characterized. In magnetite-rich iron oxide nanocrystals, size-dependent magnetic permeability is not observed, while maghemite iron oxide nanocrystals show clear size dependence. The inductance, resistance, and quality factor of hand-wound inductors with a superparamagnetic composite core are measured. The superparamagnetic nanocrystals are successfully embedded into hand-wound inductors to function as inductor cores.

  11. Size- and Composition-Dependent Radio Frequency Magnetic Permeability of Iron Oxide Nanocrystals

    SciTech Connect

    Yun, H; Liu, XY; Paik, T; Palanisamy, D; Kim, J; Vogel, WD; Viescas, AJ; Chen, J; Papaefthymiou, GC; Kikkawa, JM; Allen, MG; Murray, CB

    2014-12-01

    We investigate the size- and composition-dependent ac magnetic permeability of superparamagnetic iron oxide nanocrystals for radio frequency (RF) applications. The nanocrystals are obtained through high-temperature decomposition synthesis, and their stoichiometry is determined by Mossbauer spectroscopy. Two sets of oxides are studied: (a) as-synthesized magnetite-rich and (b) aged maghemite nanocrystals. All nanocrystalline samples are confirmed to be in the superparamagnetic state at room temperature by SQUID magnetometry. Through the one-turn inductor method, the ac magnetic properties of the nanocrystalline oxides are characterized. In magnetite-rich iron oxide nanocrystals, size-dependent magnetic permeability is not observed, while maghemite iron oxide nanocrystals show clear size dependence. The inductance, resistance, and quality factor of hand-wound inductors with a superparamagnetic composite core are measured. The superparamagnetic nanocrystals are successfully embedded into hand-wound inductors to function as inductor cores.

  12. Composites with tuned effective magnetic permeability

    NASA Astrophysics Data System (ADS)

    Amirkhizi, Alireza V.; Nemat-Nasser, Sia

    2007-07-01

    Pendry et al. [J. B. Pendry, A. J. Holden, D. J. Robbins, and W. J. Stewart, IEEE Trans. Microwave Theory Tech. 47, 2075 (1999)] and Smith et al. [D. R. Smith, W. J. Padilla, D. C. Vier, S. C. Nemat-Nasser, and S. Schultz, Phys. Rev. Lett. 84, 4184 (2000)] have shown that the effective magnetic permeability, μ, of free space can be rendered negative over a certain frequency range by a periodic arrangement of very thin conductors with suitable magnetic resonance properties, the so-called split-ring resonators. Because of its rather bulky architecture, this structure does not lend itself to a proper integration into a reasonably thin real composite structural panel. To remedy this fundamental barrier, we invented a new magnetic resonator consisting of very thin folded plates that are suitably nested within one another to form folded-doubled resonators (FDRs) that can be integrated into an actual composite panel. Measurements, using a focused beam electromagnetic characterization system combined with time-domain numerical simulations of the reflection and transmission coefficients of such a composite slab have revealed that indeed the composite has a negative μ over a frequency range of about 9.1-9.35 GHz [S. Nemat-Nasser, S. C. Nemat-Nasser, T. A. Plaisted, A. Starr, and A. Vakil Amirkhizi, in Biomimetics: Biologically Inspired Technologies, edited by Y. Bar Cohen (CRC Press, Boca Raton, FL, 2006)]. Thus, it has become possible to construct a structural composite panel with negative index of refraction by simultaneously creating negative effective ɛ and μ [V. G. Veselago, Sov. Phys. Usp. 10, 509 (1968); R. A. Shelby, D. R. Smith, and S. Schultz, Science 292, 77 (2001); A. F. Starr, P. M. Rye, D. R. Smith, and S. Nemat-Nasser, Phys. Rev. B 70, 113102 (2004)].

  13. Lunar magnetic permeability, magnetic fields, and electrical conductivity temperature

    NASA Technical Reports Server (NTRS)

    Parkin, C. W.

    1978-01-01

    In the time period 1969-1972 a total of five magnetometers were deployed on the lunar surface during four Apollo missions. Data from these instruments, along with simultaneous measurements from other experiments on the moon and in lunar orbit, were used to study properties of the lunar interior and the lunar environment. The principal scientific results from analyses of the magnetic field data are discussed. The results are presented in the following main categories: (1) lunar electrical conductivity, temperature, and structure; (2) lunar magnetic permeability, iron abundance, and core size limits; (3) the local remnant magnetic fields, their interaction with the solar wind, and a thermoelectric generator model for their origin. Relevant publications and presented papers are listed.

  14. Demonstrations of Magnetic Phenomena: Measuring the Air Permeability Using Tablets

    ERIC Educational Resources Information Center

    Lara, V. O. M.; Amaral, D. F.; Faria, D.; Vieira, L. P.

    2014-01-01

    We use a tablet to experimentally determine the dependencies of the magnetic field (B) on the electrical current and the axial distance from a coil (z). Our data shows good precision on the inverse cubic dependence of the magnetic field on the axial distance, B?z[superscript -3]. We obtain the value of air permeability µ[subscript air] with good…

  15. AC losses in a HTS coil carrying DC current in AC external magnetic field

    NASA Astrophysics Data System (ADS)

    Ogawa, J.; Zushi, Y.; Fukushima, M.; Tsukamoto, O.; Suzuki, E.; Hirakawa, M.; Kikukawa, K.

    2003-10-01

    We electrically measured AC losses in a Bi2223/Ag-sheathed pancake coil excited by a DC current in AC external magnetic field. Losses in the coil contain two kinds of loss components that are the magnetization losses and dynamic resistance losses. In the measurement, current leads to supply a current to the coil were specially arranged to suppress electromagnetic coupling between the coil current and the AC external magnetic field. A double pick-up coils method was used to suppress a large inductive voltage component contained in voltage signal for measuring the magnetization losses. It was observed that the magnetization losses were dependent on the coil current and that a peak of a curve of the loss factor vs. amplitude of the AC external magnetic field shifted to lower amplitude of the AC magnetic field as the coil current increased. This result suggests the full penetration magnetic field of the coil tape decreases as the coil current increases. The dynamic resistance losses were measured by measuring a DC voltage appearing between the coil terminals. It was observed that the DC voltage appearing in the coil subject to the AC external magnetic field was much larger than that in the coil subject to DC magnetic field.

  16. ac Magnetization transport and power absorption in nonitinerant spin chains.

    PubMed

    Trauzettel, Björn; Simon, Pascal; Loss, Daniel

    2008-07-04

    We investigate the ac transport of magnetization in nonitinerant quantum systems such as spin chains described by the XXZ Hamiltonian. Using linear response theory, we calculate the ac magnetization current and the power absorption of such magnetic systems. Remarkably, the difference in the exchange interaction of the spin chain itself and the bulk magnets (i.e., the magnetization reservoirs), to which the spin chain is coupled, strongly influences the absorbed power of the system. This feature can be used in future spintronic devices to control power dissipation. Our analysis allows us to make quantitative predictions about the power absorption, and we show that magnetic systems are superior to their electronic counterparts.

  17. Hard magnetization direction and its relation with magnetic permeability of highly grain-oriented electrical steel

    NASA Astrophysics Data System (ADS)

    Wang, Hao; Li, Chang-sheng; Zhu, Tao

    2014-11-01

    The magnetic properties of highly grain-oriented electrical steel vary along different directions. In order to investigate these properties, standard Epstein samples were cut at different angles to the rolling direction. The hard magnetization direction was found at an angle of 60° to the rolling direction. To compare the measured and fitting curves, when the magnetic field intensity is higher than 7000 A/m, it is appropriate to simulate the relation of magnetic permeability and magnetization angle using the conventional elliptical model. When the magnetic field intensity is less than 3000 A/m, parabolic fitting models should be used; but when the magnetic field intensity is between 3000 and 7000 A/m, hybrid models with high accuracy, as proposed in this paper, should be applied. Piecewise relation models of magnetic permeability and magnetization angle are significant for improving the accuracy of electromagnetic engineering calculations of electrical steel, and these new models could be applied in further industrial applications.

  18. High permeability flexible bulk material for magnetic micro head applications

    NASA Astrophysics Data System (ADS)

    Belski, A.; Taptimthong, P.; Wurz, M. C.; Rissing, L.

    2013-01-01

    A magnetic field is generated by feeding electric current to micro coils. The higher the current, the higher the magnetic field is. A main disadvantage of coils in micro systems is the limited thermal resistance and as a result of a restriction concerning the maximum current densities. This work shows the modelling, design, numerical calculation and the initial test of a flexible write head, which not only allows the data storage on the surface but also inside of the components. Furthermore, the write head has to be flexible and able to adapt itself to the roughness of the component surface. The main goal of this paper is to increase the magnetic flux in the micro head core by partly using high permeability flexible bulk material instead of increasing the coil current or the number of the coil turns. For the approval of the data storage process a GMR sensor is used for the readout of the stored magnetization track.

  19. Measurement of AC electrical characteristics of SSC superconducting dipole magnets

    SciTech Connect

    Smedley, K M; Shafer, R E

    1992-01-01

    Experiments were conducted to measure the AC electrical characteristics of SSC superconducting dipole magnets over the frequency range of 0.1 Hz to 10 kHz. A magnet equivalent circuit representing the magnet DC inductance, eddy current losses, coil-to-ground and turn-to-turn capacitance, was synthesized from the experimental data. This magnet equivalent circuit can be used to predict the current ripple distribution along the superconducting magnet string and can provide dynamic information for the design of the collider current regulation loop.

  20. Ac magnetic susceptibility study of in vivo nanoparticle biodistribution

    NASA Astrophysics Data System (ADS)

    Gutiérrez, L.; Mejías, R.; Barber, D. F.; Veintemillas-Verdaguer, S.; Serna, C. J.; Lázaro, F. J.; Morales, M. P.

    2011-06-01

    We analysed magnetic nanoparticle biodistribution, before and after cytokine conjugation, in a mouse model by ac susceptibility measurements of the corresponding resected tissues. Mice received repeated intravenous injections of nanoparticle suspension for two weeks and they were euthanized 1 h after the last injection. In general, only 10% of the total injected nanoparticles after multiple exposures were found in tissues. The rest of the particles may probably be metabolized or excreted by the organism. Our findings indicate that the adsorption of interferon to DMSA-coated magnetic nanoparticles changes their biodistribution, reducing the presence of nanoparticles in lungs and therefore their possible toxicity. The specific targeting of the particles to tumour tissues by the use of an external magnetic field has also been studied. Magnetic nanoparticles were observed by transmission electron microscopy in the targeted tissue and quantified by ac magnetic susceptibility.

  1. AC Loss Analysis on the Superconducting Coupling Magnet in MICE

    SciTech Connect

    Wu, Hong; Wang, Li; Green, Michael; Li, LanKai; Xu, FengYu; Liu, XiaoKun; Jia, LinXinag

    2008-07-08

    A pair of coupling solenoids is used in MICE experiment to generate magnetic field which keeps the muons within the iris of thin RF cavity windows. The coupling solenoids have a 1.5-meter inner diameter and will produce 7.4 T peak magnetic field. Three types of AC losses in coupling solenoid are discussed. The affect of AC losses on the temperature distribution within the cold mass during charging and rapid discharging process is analyzed also. The analysis result will be further confirmed by the experiment of the prototype solenoid for coupling solenoid, which will be designed, fabricated and tested at ICST.

  2. Total AC losses in twisted and untwisted multifilamentary Bi-2223 superconducting tapes carrying AC transport current in AC longitudinal magnetic field

    NASA Astrophysics Data System (ADS)

    Amemiya, Naoyuki; Jin, Feng; Jiang, Zhenan; Shirai, Shunsuke; ten Haken, Bennie; Rabbers, Jan-Jaap; Ayai, Naoki; Hayashi, Kazuhiko

    2003-03-01

    In some electrical apparatuses, superconducting tapes are exposed to the longitudinal magnetic field. In this work, AC losses were measured in twisted and untwisted Bi-2223 tapes carrying AC transport current in the AC longitudinal magnetic field. In twisted tapes, the transport, magnetization and total losses depend on the relative direction of the longitudinal magnetic field to the direction of the transport current, while the field direction does not influence the AC loss characteristics in untwisted tapes. In the Z-twisted tapes, the total AC loss is larger in the longitudinal magnetic field that is anti-parallel to the transport current than in the longitudinal magnetic field of another direction. Numerical analysis shows that this field direction dependence of the total AC loss results from the change in the current distribution. In the longitudinal magnetic field that is anti-parallel to the transport current, the total AC loss in the Z-twisted tape is more than that in the untwisted tape. This dependence on the field direction is reversed in S-twisted tapes. It is to be noted that the twist increases the total AC loss in a longitudinal magnetic field of a certain direction, while it reduces the AC loss in the transverse magnetic field.

  3. Simultaneous identification of electric permittivity and magnetic permeability

    NASA Astrophysics Data System (ADS)

    Feng, Hui; Jiang, Daijun; Zou, Jun

    2010-09-01

    In this paper we investigate the simultaneous reconstruction of the electric permittivity and magnetic permeability. The two physical parameters are allowed to be highly discontinuous in the concerned physical domain. The ill-posed inverse problem is formulated into an output least-squares nonlinear minimization with BV-regularization. The regularizing effect and mathematical properties of the regularized system are justified and analysed. A fully discrete Nedelec's edge element method is applied to approximate the regularized nonlinear optimization system, and its convergence is demonstrated.

  4. SQUIDs De-fluxing Using a Decaying AC Magnetic Field

    SciTech Connect

    Matlashov, Andrei Nikolaevich; Semenov, Vasili Kirilovich; Anderson, Bill

    2016-06-08

    Flux trapping is the Achilles’ heel of all superconductor electronics. The most direct way to avoid flux trapping is a prevention of superconductor circuits from exposure to magnetic fields. Unfortunately this is not feasible if the circuits must be exposed to a strong DC magnetic field even for a short period of time. For example, such unavoidable exposures take place in superparamagnetic relaxation measurements (SPMR) and ultra-low field magnetic resonance imaging (ULF MRI) using unshielded thin-film SQUID-based gradiometers. Unshielded SQUIDs stop working after being exposed to DC magnetic fields of only a few Gauss in strength. In this paper we present experimental results with de-fluxing of planar thin-film LTS SQUID-based gradiometers using a strong decaying AC magnetic field. We used four commercial G136 gradiometers for SPMR measurements with up to a 10 mT magnetizing field. Strong 12.9 kHz decaying magnetic field pulses reliably return SQUIDs to normal operation 50 ms after zeroing the DC magnetizing field. This new AC de-fluxing method was also successfully tested with seven other different types of LTS SQUID sensors and has been shown to dissipate extremely low energy.

  5. Testing of a First Order AC Magnetic Susceptometer

    NASA Astrophysics Data System (ADS)

    Fukuda, Ryan; Sunny, Smitha; Ho, Pei-Chun

    2011-11-01

    A first-order AC magnetic susceptometer has been constructed and tested to find the magnetic response of strongly correlated electron materials. The instrument works by using a primary coil to apply a small AC magnetic field of .104 Oe to a sample with a cylindrical coil space of length .635 cm and diameter .355 cm. A lock-in amplifier is used to monitor the induced voltage from a set of secondary coils. By coupling a temperature-controlled system with this instrument, the change in the magnetic signal with respect to temperature is measured. Monitoring the signal changes may indicate the temperature that causes the material to transition to either a ferromagnetic, anti-ferromagnetic, or superconducting state. A 122.47 mg Gd polycrystal was used to test our susceptometer. The data qualitatively agrees with the previous results of magnetization vs. temperature of Gd single crystals by Nigh et al. [1]: there is a steep increase in the pick-up signal at 300 K where Gd becomes ferromagnetic and a peak at 210 K [1]. This susceptometer will be used for our future investigation of magnetic properties of rare earth compounds and nanoparticles in the temperature range of 10 K to 300 K. [4pt] [1] H. E. Nigh, S. Legvold, and F. H. Spedding, Physical Review 132, 1092 (1963)

  6. AC Losses in the MICE Channel Magnets -- Is This a Curse or aBlessing?

    SciTech Connect

    Green, M.A.; Wu, H.; Wang, L.; Kai, L.L.; Jia, L.X.; Yang, S.Q.

    2008-01-31

    This report discusses the AC losses in the MICE channelmagnets during magnet charging and discharging. This report talks aboutthe three types of AC losses in the MICE magnets; the hysteretic AC lossin the superconductor, the coupling AC loss in the superconductor and theeddy current AC loss in the magnet mandrel and support structure. AClosses increase the heat load at 4 K. The added heat load increases thetemperature of the second stage of the cooler. In addition, AC losscontributes to the temperature rise between the second stage cold headand the high field point of the magnet, which is usually close to themagnet hot spot. These are the curses of AC loss in the MICE magnet thatcan limit the rate at which the magnet can be charge or discharged. Ifone is willing to allow some of the helium that is around the magnet toboil away during a magnet charge or discharge, AC losses can become ablessing. The boil off helium from the AC losses can be used to cool theupper end of the HTS leads and the surrounding shield. The AC losses arepresented for all three types of MICE magnets. The AC loss temperaturedrops within the coupling magnet are presented as an example of how boththe curse and blessing of the AC losses can be combined.

  7. AC Magnetic Field Frequency Dependence of Magnetoacoustic Emission

    NASA Technical Reports Server (NTRS)

    Namkung, M.; Wincheski, B.; Fulton, J. P.; DeNale, R.

    1992-01-01

    Our recent study has proved a strong correlation between the low-frequency AC applied magnetic field amplitude dependence of the asymmetry of the magnetoacoustic emission (MAE) burst and the strength of the domain wall-defect interaction in iron-base ferromagnets. For the present study the AC magnetic field frequency dependence of the asymmetry has been investigated in the range of 1 to 200 Hz. When represented by the third moment of the rectified acoustic emission pulses, the asymmetry becomes a bell-shaped function of frequency with its center located around 25 Hz. This experiment has been performed with low carbon, high yield stress steel specimens of three different levels of domain wall-defect interaction strength. The results show that the increase in the interaction strength causes a vertical down shift of the asymmetry in the entire frequency range investigated.

  8. Measured losses in superconductor magnets for 60-Hertz ac operation.

    NASA Technical Reports Server (NTRS)

    Hamlet, I. L.; Kilgore, R. A.

    1971-01-01

    Results of an experimental study of electrical losses in superconductor magnets. Preliminary 60-Hz ac loss data are presented for coils constructed of Nb3Sn ribbon, Nb-Ti cable, and multifilament Nb-Ti. Losses have been measured for different size coils up to approximately 20 cm in diameter. Of the conductor types tested, Nb3Sn ribbon has the lowest losses for ac operation. In Nb3Sn-ribbon coils of different sizes, the loss per unit length of conductor is shown to decrease with a decrease in the rate of change of current and to increase, in general, with increase in coil size. An important aspect of the study is the high degree of repeatability of the data.

  9. Water Permeability of Chlorella Cell Membranes by Nuclear Magnetic Resonance

    PubMed Central

    Stout, Darryl G.; Steponkus, Peter L.; Bustard, Larry D.; Cotts, Robert M.

    1978-01-01

    Measurement by two nuclear magnetic resonance (NMR) techniques of the mean residence time τa of water molecules inside Chlorella vulgaris (Beijerinck) var. “viridis” (Chodot) is reported. The first is the Conlon and Outhred (1972 Biochim Biophys Acta 288: 354-361) technique in which extracellular water is doped with paramagnetic Mn2+ ions. Some complications in application of this technique are identified as being caused by the affinity of Chlorella cell walls for Mn2+ ions which shortens the NMR relaxation times of intra- and extracellular water. The second is based upon observations of effects of diffusion on the spin echo of intra- and extracellular water. Echo attenuation of intracellular water is distinguished from that of extracellular water by the extent to which diffusive motion is restricted. Intracellular water, being restricted to the cell volume, suffers less echo attenuation. From the dependence of echo amplitude upon gradient strength at several values of echo time, the mean residence time of intracellular water can be determined. From the mean residence time of intracellular water, the diffusional water permeability coefficient of the Chlorella membrane is calculated to be 2.1 ± 0.4 × 10−3 cm sec−1. PMID:16660456

  10. Permeability measurement of soft magnetic films at high frequency and multilayering effect

    SciTech Connect

    Senda, M.

    1993-03-01

    This paper reports a new method for the measurement of permeability at high frequencies (1 MHz to 1 GHz). An inductance line with a magnetic/conductive/magnetic layer structure was used to estimate the permeability. The inductance line made it possible to measure frequency characteristics of the permeability up to the GHz range because of a low stray capacitance and high resonance frequency. The magnetic film pattern was designed so as to eliminate demagnetizing field effects, and the permeability was estimated based on analysis of the magnetic circuit. Using this method, NiFe/SiO[sub 2] and (Fe/SiO[sub 2])/SiO[sub 2] multilayer films were confirmed to show superior frequency characteristics by a factor of 20 over those of NiFe single-layer film. Also, ferromagnetic resonance (FMR) was observed in these multilayer films at 650 and 750 MHz.

  11. Differential device for the determination of magnetic permeability or electric resistivity inside massive cylindrical samples

    SciTech Connect

    Ursu, D.D.; Bursuc, I.D.

    1985-03-01

    A differential device for the determination of magnetic permeability or electric resistivity of the ferromagnetic cylindrical samples was realized. Our method, which takes into account a simple model of hysteresis, leads to encouraging results.

  12. New levitation scheme with AC superconducting magnet for EDS MAGLEV system

    SciTech Connect

    Kim, D.H.; Lee, J.K.; Hahn, S.Y.; Cha, G.

    1996-09-01

    This paper proposes a new magnetic levitation scheme which is able to generate levitation force for all speeds including a standstill. Auxiliary wheels which are needed in EDS MAGLEV vehicle can be eliminated. This scheme uses AC superconducting magnets to generate levitation force. In this paper, magnetic fields, forces and power dissipations generated by AC magnets moving above a conducting slab are calculated analytically. Results of calculation show characteristics of EDS system with AC magnet, such as levitation force and loss, are superior to those of EDS system with DC magnets for all speeds.

  13. ac susceptibility study of a magnetite magnetic fluid

    NASA Astrophysics Data System (ADS)

    Ayala-Valenzuela, O. E.; Matutes-Aquino, J. A.; Galindo, J. T. Elizalde; Botez, C. E.

    2009-04-01

    Magnetite nanometric powder was synthesized from metal salts using a coprecipitation technique. The powders were used to produce magnetic fluid via a peptization method, with hydrocarbon Isopar M as liquid carrier and oleic acid as surfactant. The complex magnetic susceptibility χ =χ'+iχ″ was measured as a function of temperature T in steps of 2.5 K from 3 to 298 K for frequencies ranging from f =10 to 10 000 Hz. The magnetic fluid real and imaginary components of the ac susceptibility show a prominent maximum at temperatures that increase with the measuring frequency, which is attributed to a spin-glass-like behavior. The peak temperature Tp1 of χ″ depends on f following the Vogel-Fulcher law f =f0 exp[E /kB(Tp1-T0)], where f0 and E are positive constants and T0 is a parameter related to particle interactions. There is another kind of peak temperature, Tp2, in the loss factor tan δ =χ″/χ' which is related to a magnetic aftereffect. The peak temperature Tp2 is far less than Tp1 and shows an Arrhenius-type dependence on f.

  14. Magnetic tweezers with high permeability electromagnets for fast actuation of magnetic beads

    SciTech Connect

    Chen, La; Offenhäusser, Andreas; Krause, Hans-Joachim

    2015-04-15

    As a powerful and versatile scientific instrument, magnetic tweezers have been widely used in biophysical research areas, such as mechanical cell properties and single molecule manipulation. If one wants to steer bead position, the nonlinearity of magnetic properties and the strong position dependence of the magnetic field in most magnetic tweezers lead to quite a challenge in their control. In this article, we report multi-pole electromagnetic tweezers with high permeability cores yielding high force output, good maneuverability, and flexible design. For modeling, we adopted a piece-wise linear dependence of magnetization on field to characterize the magnetic beads. We implemented a bi-linear interpolation of magnetic field in the work space, based on a lookup table obtained from finite element simulation. The electronics and software were custom-made to achieve high performance. In addition, the effects of dimension and defect on structure of magnetic tips also were inspected. In a workspace with size of 0.1 × 0.1 mm{sup 2}, a force of up to 400 pN can be applied on a 2.8 μm superparamagnetic bead in any direction within the plane. Because the magnetic particle is always pulled towards a tip, the pulling forces from the pole tips have to be well balanced in order to achieve control of the particle’s position. Active video tracking based feedback control is implemented, which is able to work at a speed of up to 1 kHz, yielding good maneuverability of the magnetic beads.

  15. Magnetic tweezers with high permeability electromagnets for fast actuation of magnetic beads.

    PubMed

    Chen, La; Offenhäusser, Andreas; Krause, Hans-Joachim

    2015-04-01

    As a powerful and versatile scientific instrument, magnetic tweezers have been widely used in biophysical research areas, such as mechanical cell properties and single molecule manipulation. If one wants to steer bead position, the nonlinearity of magnetic properties and the strong position dependence of the magnetic field in most magnetic tweezers lead to quite a challenge in their control. In this article, we report multi-pole electromagnetic tweezers with high permeability cores yielding high force output, good maneuverability, and flexible design. For modeling, we adopted a piece-wise linear dependence of magnetization on field to characterize the magnetic beads. We implemented a bi-linear interpolation of magnetic field in the work space, based on a lookup table obtained from finite element simulation. The electronics and software were custom-made to achieve high performance. In addition, the effects of dimension and defect on structure of magnetic tips also were inspected. In a workspace with size of 0.1 × 0.1 mm(2), a force of up to 400 pN can be applied on a 2.8 μm superparamagnetic bead in any direction within the plane. Because the magnetic particle is always pulled towards a tip, the pulling forces from the pole tips have to be well balanced in order to achieve control of the particle's position. Active video tracking based feedback control is implemented, which is able to work at a speed of up to 1 kHz, yielding good maneuverability of the magnetic beads.

  16. Temperature dependence dynamical permeability characterization of magnetic thin film using near-field microwave microscopy.

    PubMed

    Hung, Le Thanh; Phuoc, Nguyen N; Wang, Xuan-Cong; Ong, C K

    2011-08-01

    A temperature dependence characterization system of microwave permeability of magnetic thin film up to 5 GHz in the temperature range from room temperature up to 423 K is designed and fabricated as a prototype measurement fixture. It is based on the near field microwave microscopy technique (NFMM). The scaling coefficient of the fixture can be determined by (i) calibrating the NFMM with a standard sample whose permeability is known; (ii) by calibrating the NFMM with an established dynamic permeability measurement technique such as shorted microstrip transmission line perturbation method; (iii) adjusting the real part of the complex permeability at low frequency to fit the value of initial permeability. The algorithms for calculating the complex permeability of magnetic thin films are analyzed. A 100 nm thick FeTaN thin film deposited on Si substrate by sputtering method is characterized using the fixture. The room temperature permeability results of the FeTaN film agree well with results obtained from the established short-circuited microstrip perturbation method. Temperature dependence permeability results fit well with the Landau-Lifshitz-Gilbert equation. The temperature dependence of the static magnetic anisotropy H(K)(sta), the dynamic magnetic anisotropy H(K)(dyn), the rotational anisotropy H(rot), together with the effective damping coefficient α(eff), ferromagnetic resonance f(FMR), and frequency linewidth Δf of the thin film are investigated. These temperature dependent magnetic properties of the magnetic thin film are important to the high frequency applications of magnetic devices at high temperatures.

  17. Power-law resistivity, magnetic relaxation and ac susceptibility

    SciTech Connect

    Gilchrist, J.; van der Beek, C.J.

    1994-07-01

    The nonlinear diffusion of magnetic flux into a superconducting sample can be studied by measuring the relaxation of the magnetisation after application of a step field or by measuring the ac susceptibility, {chi}{sub 1} and its third harmonic, {chi}{sub 3}, or preferably both methods covering different time scales. Each has been analysed recently for a field-cooled sample of a material whose creep activation energy depends logarithmically on current density, J corresponding to a power-law relation between electric field, E and J. Here, results are compared, using a universal scaling depth. Maximum {chi}{sub 1}{double_prime} {vert_bar}{chi}{sub 3}{vert_bar} and values occur, and also the magnetisation has relaxed to half its initial value when the scaling depth is comparable to the sample half-thickness.

  18. Ac magnetorestriction hysteresis and magnetization direction in grain oriented silicon steels

    SciTech Connect

    Mogi, Hisashi; Matsuo, Yukio; Kumano, Tomoji

    1999-09-01

    A hysteresis curve of ac magnetostriction was measured, magnetizing a grain oriented silicon steel in the direction deviated from rolling direction of a sample. The ac magnetostriction ({lambda} ac) curves were analyzed as harmonics in the interest of noise spectrum of such as a power transformer. The domain structure model in this magnetostriction process was proposed. The hysteresis was large in the magnetization direction inclined at 30 and 90{degree} from the rolling direction.

  19. Spectroscopic AC Susceptibility Imaging (sASI) of Magnetic Nanoparticles.

    PubMed

    Ficko, Bradley W; Nadar, Priyanka M; Diamond, Solomon G

    2015-02-01

    This study demonstrates a method for alternating current (AC) susceptibility imaging (ASI) of magnetic nanoparticles (mNPs) using low cost instrumentation. The ASI method uses AC magnetic susceptibility measurement to create tomographic images using an array of drive coils, compensation coils and fluxgate magnetometers. Using a spectroscopic approach in conjunction with ASI, a series of tomographic images can be created for each frequency measurement and is termed sASI. The advantage of sASI is that mNPs can be simultaneously characterized and imaged in a biological medium. System calibration was performed by fitting the in-phase and out-of-phase susceptibility measurements of an mNP sample with a hydrodynamic diameter of 100 nm to a Brownian relaxation model (R(2) = 0.96). Samples of mNPs with core diameters of 10 and 40 nm and a sample of 100 nm hydrodynamic diameter were prepared in 0.5 ml tubes. Three mNP samples were arranged in a randomized array and then scanned using sASI with six frequencies between 425 and 925 Hz. The sASI scans showed the location and quantity of the mNP samples (R(2) = 0.97). Biological compatibility of the sASI method was demonstrated by scanning mNPs that were injected into a pork sausage. The mNP response in the biological medium was found to correlate with a calibration sample (R(2) = 0.97, p <0.001). These results demonstrate the concept of ASI and advantages of sASI.

  20. Spectroscopic AC susceptibility imaging (sASI) of magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Ficko, Bradley W.; Nadar, Priyanka M.; Diamond, Solomon G.

    2015-02-01

    This study demonstrates a method for alternating current (AC) susceptibility imaging (ASI) of magnetic nanoparticles (mNPs) using low cost instrumentation. The ASI method uses AC magnetic susceptibility measurements to create tomographic images using an array of drive coils, compensation coils and fluxgate magnetometers. Using a spectroscopic approach in conjunction with ASI, a series of tomographic images can be created for each frequency measurement set and is termed sASI. The advantage of sASI is that mNPs can be simultaneously characterized and imaged in a biological medium. System calibration was performed by fitting the in-phase and out-of-phase susceptibility measurements of an mNP sample with a hydrodynamic diameter of 100 nm to a Brownian relaxation model (R2=0.96). Samples of mNPs with core diameters of 10 and 40 nm and a sample of 100 nm hydrodynamic diameter were prepared in 0.5 ml tubes. Three mNP samples were arranged in a randomized array and then scanned using sASI with six frequencies between 425 and 925 Hz. The sASI scans showed the location and quantity of the mNP samples (R2=0.97). Biological compatibility of the sASI method was demonstrated by scanning mNPs that were injected into a pork sausage. The mNP response in the biological medium was found to correlate with a calibration sample (R2=0.97, p<0.001). These results demonstrate the concept of ASI and advantages of sASI.

  1. The thermoelectric power of Al-0.99 wt.% Fe alloys in the AC magnetic field

    NASA Astrophysics Data System (ADS)

    Lan, Qing; Zhang, Jianfeng; Liu, Xuan; Le, Qichi; Yin, Siqi; Liu, Yiting; Cui, Jianzhong

    2017-04-01

    The melt structure of Al-0.99 wt.% Fe alloys in the AC magnetic field have been studied with thermoelectric power by the four-point probe technique and microstructure with the liquid quenching method. The melt temperature is in the range of 913 K–1013 K. The thermoelectric power increases due to the AC magnetic field and decreases after the AC magnetic field stops, then keeps stable. Some characteristic parameters of thermoelectric power in the recovery process are used to represent the variation of melt structure. The α-Al phase refinement in the AC magnetic field is attributed to the persistent variation of melt structure. The persistent variation of thermoelectric power can be used to characterize the variation of the α-Al phase size. The hardness increases and the diffraction peaks of some planes reduce, which can reflect the uniform and disorder melt structure in the AC magnetic field.

  2. Multiplexed sensing based on Brownian relaxation of magnetic nanoparticles using a compact AC susceptometer

    NASA Astrophysics Data System (ADS)

    Park, Kyoungchul; Harrah, Tim; Goldberg, Edward B.; Guertin, Robert P.; Sonkusale, Sameer

    2011-02-01

    A novel multiplexed sensing scheme based on the measurement of the magnetic susceptibility of the affinity captured target molecules on magnetic nanoparticles in liquid suspension is proposed. The AC magnetic susceptibility provides a measurement of Brownian relaxation behavior of biomolecules bound to magnetic nanoparticles (MNPs) that is related to its hydrodynamic size. A room temperature, compact AC susceptometer is designed and developed to measure complex AC magnetic susceptibility of such magnetic nanoparticles. The AC susceptometer exhibits high sensitivity in magnetic fields as low as 10 µT for 1 mg ml-1 concentration and 5 µl volume, and is fully software programmable. The capability of biological sensing using the proposed scheme has been demonstrated in proof of principle using the binding of biotinylated horseradish peroxidase (HRP) to streptavidin-coated MNPs. The proposed technique and instrument are readily compatible with lab-on-chip applications for point-of-care medical applications.

  3. Iron abundance and magnetic permeability of the moon

    NASA Technical Reports Server (NTRS)

    Parkin, C. W.; Daily, W. D.; Dyal, P.

    1974-01-01

    A set of simultaneous data from the Apollo 12 lunar surface magnetometer and the Explorer 35 Ames magnetometer are used to construct a whole-moon hysteresis curve, from which a new value of global lunar permeability is determined to be mu = 1.012 + or - 0.006. The corresponding global induced dipole moment is 2.1 x 10 to the 18th power gauss-cucm for typical inducing fields of .1000 gauss in the lunar environment. From the permeability measurement, lunar free iron abundance is determined to be 2.5 + or - 2.0 wt. %. Total iron abundance is calculated for two assumed compositional models of the lunar interior: a free iron/orthopyroxene lunar composition and a free iron/olivine composition. The overall lunar total iron abundance is determined to be 9.0 + or - 4.7 wt. %. Other lunar models with a small iron core and with a shallow iron-rich layer are discussed in light of the measured global permeability. Effects on permeability and iron content calculations due to a possible lunar ionosphere are also considered.

  4. Tuning Polymer Nanocomposite Morphology: Magnetic and AC Electric Field Manipulation of Epoxy - Montmorillonite (Clay) Suspensions

    NASA Astrophysics Data System (ADS)

    Vaia, Richard; Koerner, Hilmar; Jacobs, J. David; Busbee, John; Hampton, Edwin; Dean, Derrick

    2004-03-01

    The next revolutionary leap forward for polymer nano-'composites' necessitates the development of tools to transform the currently random or ill-defined nanoscale morphologies into compositionally and spatially engineered hierarchal structures, paralleling that underpinning conventional continuous fiber reinforced composites and enabling experimental verification of morphology-mechanical property correlations. Here in, utilization of AC electric fields of modest strength (1-10 V/micron) is demonstrated as a general approach to align organically modified layered silicates (OLS) parallel to the electric field - enhancing CTE, modulus and optical clarity in the reinforced direction. Interfacial polarization arising from electrophoric motion of the organic-modifier on the layer surface induces a dipole parallel to the plane of the layer, which couples to the external field. Comparably, application of a static magnetic field (0.5-2 T) induces alignment of the layers parallel or perpendicular to the field, depending on the chemical composition of the OLS. The impact of field magnitude, field frequency, dielectric permittivity and magnetic permeability of the system is discussed to elucidate the molecular characteristics of induced dipole formation and establish the limits of the process.

  5. Iron abundance and magnetic permeability of the moon

    NASA Technical Reports Server (NTRS)

    Parkin, C. W.; Daily, W. D.; Dyal, P.

    1974-01-01

    A larger set of simultaneous data from the Apollo 12 lunar surface magnetometer and the Explorer 35 Ames magnetometer are used to construct a whole-moon hysteresis curve, from which a new value of global lunar permeability is determined to be mu = 1.012 + or - 0.006. The corresponding global induced dipole moment is 2.1 x 10 to the 18th power gauss-cu cm for typical inducing fields of .0001 gauss in the lunar environment. From the permeability measurement, lunar free iron abundance is determined to be 2.5 + or - 2.0 wt. %. Total iron abundance (sum of iron in the ferromagnetic and paramagnetic states) is calculated for two assumed compositional models of the lunar interior: a free iron/orthopyroxene lunar composition and a free iron/olivine composition. The overall lunar total iron abundance is determined to be 9.0 + or - 4.7 wt. %. Other lunar models with a small iron core and with a shallow iron-rich layer are discussed in light of the measured global permeability.

  6. AC conductivity of a niobium thin film in a swept magnetic field.

    PubMed

    Tsindlekht, M I; Genkin, V M; Gazi, S; Chromik, S

    2013-02-27

    We report results of measurements of the ac conductivity of a Nb superconducting thin film in a swept dc magnetic field. In the mixed state the swept dc field creates vortices at the film surface which pass through the film and form the observed ac conductivity. Vortex rate generation does not depend on the value of the dc field and there is a large plateau-like region of dc magnetic fields where the dissipation is approximately constant. A proposed phenomenological model describes quite well the main features of the ac response in these fields, including its dependency on the sweep rate, ac amplitude, frequency, and value of the second and third harmonics.

  7. Design of Low Temperature AC Susceptibility Measurement Scheme for Molecular Magnets

    NASA Astrophysics Data System (ADS)

    Korenblit, Simcha; Moon, Byoung; Lee, Yoonseok; Sultan, Reza

    2006-03-01

    AC susceptibility is one of the most important physical properties in many materials such as magnetic materials and superconductors. Although there are many commercial AC susceptibility measurement systems which cover a broad range of temperatures, it is still a daunting task to extend their measurement range into the low millikelvins. We are currently developing a low temperature AC susceptometer for the mK range. As a part of this effort, we have developed a versatile low-cost computer controlled coil-winder to make various types of coils. We have designed primary and secondary coils and wound them using the machine, and performed characterization of the AC susceptometer. In this presentation, I will explain the basics of magnetic susceptibility, its measurement, design considerations for building an AC magnetic susceptometer, and discuss the details of an actual apparatus designed and realized by the authors.

  8. AC Magnetic Properties of Large Volume of Water — Susceptibility Measurement in Unshielded Environment

    NASA Astrophysics Data System (ADS)

    Tsukada, Keiji; Kiwa, Toshihiko; Masuda, Yuuki

    2006-10-01

    To investigate the effect of low-frequency magnetic-field exposure of a human body, the low-frequency AC magnetic property of a large volume of water was measured by low-frequency magnetic field exposure (from 50 Hz to 1.2 kHz). The results indicate that the AC magnetic property of water is due to diamagnetism in the low-frequency range. The phase between the main magnetic field and the generated magnetic field remained constant at about 180°. Results were not affected by conductivity or pH. Moreover, the magnetic-field strength from water showed a susceptibility frequency dependence proportional to the frequency above approximately 400 Hz. Because of the incremental effects of susceptibility, the magnetic field from water was measured using a conventional magnetic sensor (magnetic resistive; MR) in an unshielded environment.

  9. Effect of carbon substitution on low magnetic field AC losses in MgB 2 single crystals

    NASA Astrophysics Data System (ADS)

    Ciszek, M.; Rogacki, K.; Karpiński, J.

    2011-11-01

    The DC magnetization and AC magnetic susceptibilities were measured for MgB2 single crystals, unsubstituted and carbon substituted with the composition of Mg(B0.94C0.06)2. AC magnetic losses were derived from the AC susceptibility data as a function of the AC amplitude and the DC bias magnetic field. From the DC magnetization loops critical current densities were derived as a function of temperature and DC field. Results show that the substitution with carbon decreases critical current densities at low external magnetic fields, in contrast to the well known effect of an increase of the critical current densities at higher magnetic fields.

  10. An induction method to calculate the complex permeability of soft magnetic films without a reference sample.

    PubMed

    Wei, Jinwu; Wang, Jianbo; Liu, Qingfang; Li, Xiaoyu; Cao, Derang; Sun, Xiaojun

    2014-05-01

    A new analytical method has been proposed by utilizing an electromagnetic induction principle with a short-circuited microstrip line jig and the complex permeability spectra can be calculated without a known reference sample. The new method using the short-circuited microstrip line can exhibit higher sensitivity and a wider frequency band than coplanar waveguide and pick-up coil. Two magnetic thin films having a good in-plane uniaxial anisotropy are measured by using the induction method. The results show typical complex permeability spectra in good agreement with the theoretical analytical results. The measured permeability values are verified by comparing with the initial susceptibility derived from the sweeping field results. The difference of measured permeability values is less than 5%.

  11. Nonmonotonic field-dependent magnetic permeability of a paramagnetic ferrofluid emulsion.

    PubMed

    Ivanov, Alexey O; Kuznetsova, Olga B

    2012-04-01

    The ferrofluid emulsion, made of kerosene-based ferrofluid droplets suspended in nonmiscible aviation oil, demonstrates experimentally the nonmonotonic dependence of the effective magnetic permeability as a function of the uniform static magnetic field. In weak fields the emulsion permeability rapidly grows; it reaches its maximum at fields on the order of 1 kA/m; after that, it decays to zero. The theoretical explanation of the effect, as we show here, could be based on the following idea: In a weak magnetic field the growth of the induced droplet magnetic moment is faster than the linear one due to the droplet elongation accompanied by the reduction of the demagnetizing field. Further increase of the external magnetic field strength cannot lead to a significant decrease of the demagnetizing field, as the droplets are already highly elongated. On the other hand, the magnetic susceptibility of the ferrofluid reduces with the field strength. Thus, the effective magnetic permeability of the ferrofluid suspension starts decreasing. The developed theoretical model describes well the experimental observations.

  12. Magnetically tunable negative permeability metamaterial composed by split ring resonators and ferrite rods.

    PubMed

    Kang, Lei; Zhao, Qian; Zhao, Hongjie; Zhou, Ji

    2008-06-09

    We experimentally demonstrate a tunable negative permeability metamaterial (NPM) at microwave frequencies by introducing yttrium iron garnet (YIG) rods into a periodic array of split ring resonators (SRRs). Different from those tuned by controlling the capacitance of equivalent LC circuit of SRR, this metamaterial is based on a mechanism of magnetically tuning the inductance via the active ambient effective permeability. For magnetic fields from 0 to 2000 Oe and from 3200 to 6000 Oe, the resonance frequencies of the metamaterial can blueshift about 350 MHz and redshift about 315 MHz, respectively. Both shifts are completely continuous and reversible. Correspondingly, the tunable negative permeabilities are widened by about 360 MHz and 200 MHz compared to that without YIG rods.

  13. Evaluation of damage-induced permeability using a three-dimensional Adaptive Continuum/Discontinuum Code (AC/DC)

    NASA Astrophysics Data System (ADS)

    Fabian, Dedecker; Peter, Cundall; Daniel, Billaux; Torsten, Groeger

    Digging a shaft or drift inside a rock mass is a common practice in civil engineering when a transportation way, such as a motorway, railway tunnel or storage shaft is to be built. In most cases, the consequences of the disturbance on the medium must be known in order to estimate the behaviour of the disturbed rock mass. Indeed, excavating part of the rock causes a new distribution of the stress field around the excavation that can lead to micro-cracking and even to the failure of some rock volume in the vicinity of the shaft. Consequently, the formed micro-cracks modify the mechanical and hydraulic properties of the rock. In this paper, we present an original method for the evaluation of damage-induced permeability. ITASCA has developed and used discontinuum models to study rock damage by building particle assemblies and checking the breakage of bonds under stress. However, such models are limited in size by the very large number of particles needed to model even a comparatively small volume of rock. In fact, a large part of most models never experiences large strains and does not require the accurate description of large-strain/damage/post-peak behaviour afforded by a discontinuum model. Thus, a large model frequently can be separated into a strongly strained “core” area to be represented by a Discontinuum and a peripheral area for which continuum zones would be adequate. Based on this observation, Itasca has developed a coupled, three-dimensional, continuum/discontinuum modelling approach. The new approach, termed Adaptive Continuum/Discontinuum Code (AC/DC), is based on the use of a periodic discontinuum “base brick” for which more or less simplified continuum equivalents are derived. Depending on the level of deformation in each part of the model, the AC/DC code can dynamically select the appropriate brick type to be used. In this paper, we apply the new approach to an excavation performed in the Bure site, at which the French nuclear waste agency

  14. Magnetization of YBCO film with ac travelling magnetic waves of relatively short wavelengths

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Coombs, Tim

    2017-02-01

    The magnetizations of the YBCO film with ac travelling magnetic waves of relatively short wavelengths were studied. The results have verified that the reported "intermediate value" of the superconducting current density [Wang et al., Appl. Phys. Lett. 104(3), 032602 (2014)] was caused by the existence of multiple transition regions in the sample: the magnetic poles induce ±JC in the pole regions, which produces two transition regions within each wavelength λ ( +JC→-JC→+JC , and vice versa, while the symbol → indicates the transition region). The current densities in the transition region are with intermediate values, which are smaller than the critical value. In case of relatively short wavelength, there are multiple transition regions, which occupy a large fraction of the YBCO sample with intermediate current values. Moreover, the wavelike current distributions might help explain the flux transportation and dc output voltage in HTS flux pump.

  15. Decrease of magnetic AC loss in twisted-filament Bi-2223 tapes

    NASA Astrophysics Data System (ADS)

    Oomen, M. P.; Rieger, J.; Leghissa, M.; Fischer, B.; Arndt, Th.

    1998-12-01

    In AC power-engineering applications, a large part of the AC loss in the superconductor is due to magnetization by the external field. This magnetic AC loss has been well described for the low- Tc conductors. In Bi-2223 tapes the picture is different due to strong anisotropy, granularity and flux creep. Magnetic AC loss in various twisted and non-twisted Bi-2223 tapes has been measured at power frequencies by a pickup method. The results are compared to theoretical models of magnetization loss. When the field is parallel to the tape plane, the filaments in twisted tapes can be decoupled and the AC loss is decreased even when the matrix is pure silver. The extra effect of higher-resistance matrix materials is studied. In perpendicular field it is more difficult to decouple the filaments, due to the particular tape geometry. Contrary to a wire, there are essential differences between the AC loss mechanisms in a long twisted tape and those in a short piece of non-twisted tape. Finally, the dynamic resistance caused by the AC magnetic field is examined.

  16. Correlation of AC Loss Data from Magnetic Susceptibility Measurements with YBCO Film Quality (Postprint)

    DTIC Science & Technology

    2012-02-01

    excimer laser operating at the KrF, 248 nm , wavelength. Substrates included LaAlO3 ( 100 ) and SrTiO3 ( 100 ) single crystal substrates as well as buffered...AFRL-RZ-WP-TP-2012-0100 CORRELATION OF AC LOSS DATA FROM MAGNETIC SUSCEPTIBILITY MEASUREMENTS WITH YBCO FILM QUALITY (POSTPRINT) Paul N...CORRELATION OF AC LOSS DATA FROM MAGNETIC SUSCEPTIBILITY MEASUREMENTS WITH YBCO FILM QUALITY (POSTPRINT) 5a. CONTRACT NUMBER In-house 5b. GRANT

  17. High-Permeability Magnetic Polymer Additives for Lightweight Electromagnetic Shielding

    DTIC Science & Technology

    2015-08-01

    dopants in polymeric electromagnetic (EM) shielding materials. The research hypothesis was that ferromagnetic polymers can be realized via doping... organic materials (no metal content) with no net magnetic moment. Because polymers can be synthesized with aromatic carbon (C) rings, however, similar...structures of the general form MxLyClx+y. Such dopants can be introduced to polymeric materials either by entrapment inside the polymer matrix (physical

  18. AC Magnetic Heating of Superparamagnetic Fe and Co Nanoparticles

    DTIC Science & Technology

    2012-06-01

    saturation magnetization, MS. As the magnitude of the field decreases the total magnetization decreases and reaches at zero field the remanent magnetization...a spontaneous random orientation of the magnetic moment inside the particles (zero remanence magnetization and coercivity, so no hysteresis

  19. Magnetic field extraction of trap-based electron beams using a high-permeability grid

    SciTech Connect

    Hurst, N. C.; Danielson, J. R.; Surko, C. M.

    2015-07-15

    A method to form high quality electrostatically guided lepton beams is explored. Test electron beams are extracted from tailored plasmas confined in a Penning-Malmberg trap. The particles are then extracted from the confining axial magnetic field by passing them through a high magnetic permeability grid with radial tines (a so-called “magnetic spider”). An Einzel lens is used to focus and analyze the beam properties. Numerical simulations are used to model non-adiabatic effects due to the spider, and the predictions are compared with the experimental results. Improvements in beam quality are discussed relative to the use of a hole in a high permeability shield (i.e., in lieu of the spider), and areas for further improvement are described.

  20. Experimental study of magnetization AC loss in MgB2 wires and cables with non-magnetic sheath

    NASA Astrophysics Data System (ADS)

    Kováč, Ján; Šouc, Ján; Kováč, Pavol; Hušek, Imrich; Gömöry, Fedor

    2013-12-01

    The influence of MgB2 wires design on the magnetization AC loss was studied. AC loss in external AC magnetic field perpendicular to the wire axis was measured in the temperature range from 18 K up to 40 K and at the frequencies of 72 Hz and 144 Hz, respectively. For this purpose the experimental apparatus combining magnetization measurement system and non-magnetic vacuum vessel with two-stage crycooler for sample cooling has been used. To clarify the influence of wire architecture on the AC loss in non-magnetic GlidCop sheathed MgB2 composites experiments on a single-core, 30-filament un-twisted and also twisted samples were performed. MgB2 cables containing 7 mono-core strands and 30 filament strands were also measured. While in the cable containing single core strands the hysteresis loss was dominant, in the un-twisted wire and the cable with un-twisted filaments the coupling loss prevailed. The effect of decoupling was observed in all twisted filamentary wires. The obtained results show that in 7 strands cable the AC loss of strands is crucial to the overall AC loss of a cable.

  1. Range Detection of the Extremely Low-Frequency Magnetic Field Produced by Laptop's AC Adapter

    NASA Astrophysics Data System (ADS)

    Brodić, Darko; Amelio, Alessia

    2017-02-01

    Human exposure to extremely low frequency magnetic field represents a risk to their health. This paper takes into consideration the level of an extremely low-frequency magnetic field between 30 and 300 Hz emitted by an AC laptop adapter. The experiment consists of testing 17 different AC adapters for laptops. During the testing, laptops are operated in a normal operating conditions as well as under heavy load. The magnetic field measurement is conducted in the area around the AC adapter. Obtained data is evaluated according to the critical level of the magnetic field proposed by safety standards. Furthermore, data is classified by a K-medians method in order to determine the critical levels of the magnetic field exposure in the nearby area of the AC adapter. Obtained classifications are evaluated according to safety standards, giving a critical analysis of magnetic field areas at risk. Due to emission of a very strong magnetic field in certain areas, a recommendation for safety use of the AC adapter is proposed.

  2. Depinning of flux lines and AC losses in magnet-superconductor levitation system

    SciTech Connect

    Terentiev, A. N.; Hull, J. R.; De Long, L. E.

    1999-11-29

    The AC loss characteristics of a magnet-superconductor system were studied with the magnet fixed to the free end of an oscillating cantilever located near a stationary melt-textured YBCO pellet. Below a threshold AC field amplitude {approx}2Oe, the dissipation of the oscillator is amplitude-independent, characteristic of a linear, non-hysteretic regime. Above threshold,dissipation increases with amplitude, reflecting the depinning and hysteretic motion of flux lines. The threshold AC field is an order of magnitude higher than that measured for the same YBCO material via AC susceptometry in a uniform DC magnetic field, A partial lock-in of flux lines between YBCO ab planes is proposed as the mechanism for the substantial increase of the depinning threshold.

  3. Total AC loss characteristics of untwisted and twisted Bi-2223 multifilamentary tapes and interaction between self and external magnetic fields

    NASA Astrophysics Data System (ADS)

    Jiang, Zhenan; Amemiya, Naoyuki; Ayai, Naoki; Hayashi, Kazuhiko

    2004-11-01

    The authors have electrically measured the total AC losses of untwisted and twisted Bi-2223 multifilamentary tapes in AC parallel and perpendicular transverse magnetic fields. The magnetization and transport losses in the untwisted and twisted Bi-2223 multifilamentary tapes carrying an AC transport current in AC parallel and perpendicular transverse magnetic fields were measured independently to obtain the total AC loss. The total AC losses of both the untwisted and twisted Bi-2223 multifilamentary tapes in a parallel transverse magnetic field are approximately equal to the sum of the transport loss without the external magnetic field and the magnetization loss without the transport current. In particular, the total AC loss of the twisted tape in a parallel transverse magnetic field is in good agreement with this sum. On the other hand, the total AC losses of both the untwisted and twisted Bi-2223 multifilamentary tapes in a perpendicular transverse magnetic field are larger than the sum of the transport loss without any external magnetic field and the magnetization loss without transport current. The total AC loss of the twisted tape in a parallel transverse magnetic field can be predicted by the sum of the magnetization loss using the slab model for an equivalent filament thickness and the transport loss given by Norris for a superconductor with an elliptical cross section.

  4. Effect of Low-Frequency AC Magnetic Susceptibility and Magnetic Properties of CoFeB/MgO/CoFeB Magnetic Tunnel Junctions

    PubMed Central

    Chen, Yuan-Tsung; Lin, Sung-Hao; Sheu, Tzer-Shin

    2014-01-01

    In this investigation, the low-frequency alternate-current (AC) magnetic susceptibility (χac) and hysteresis loop of various MgO thickness in CoFeB/MgO/CoFeB magnetic tunneling junction (MTJ) determined coercivity (Hc) and magnetization (Ms) and correlated that with χac maxima. The multilayer films were sputtered onto glass substrates and the thickness of intermediate barrier MgO layer was varied from 6 to 15 Å. An experiment was also performed to examine the variation of the highest χac and maximum phase angle (θmax) at the optimal resonance frequency (fres), at which the spin sensitivity is maximal. The results reveal that χac falls as the frequency increases due to the relationship between magnetization and thickness of the barrier layer. The maximum χac is at 10 Hz that is related to the maximal spin sensitivity and that this corresponds to a MgO layer of 11 Å. This result also suggests that the spin sensitivity is related to both highest χac and maximum phase angle. The corresponding maximum of χac is related to high exchange coupling. High coercivity and saturation magnetization contribute to high exchange-coupling χac strength.

  5. Probe imaging studies of magnetic susceptibility and permeability for sensitive characterisation of carbonate reservoir rocks

    NASA Astrophysics Data System (ADS)

    Ivakhnenko, Aleksandr; Bigaliyeva, Akmaral; Dubinin, Vladislav

    2016-04-01

    In this study were disclosed the main principals of identifying petrophysical properties of carbonate reservoirs such as porosity, permeability and magnetic susceptibility. While exploring and developing reservoir there are significant diversity of tasks that can be solved by appropriate knowledge of properties which are listed above. Behavior of fluid flow, distribution of hydrocarbons and other various industrial applications can be solved by measuring areal distribution of these petrophysical parameters. The results demonstrate how magnetic probe and hysteresis measurements correlate with petrophysical parameters in carbonate reservoirs. We made experimental measurements and theoretical calculations of how much magnetic susceptibility depends on the porosity of the rocks and analyzed data with graphics. In theoretical model of the carbonate rocks we considered calcite, dolomite, quartz and combinations of calcite and dolomite, calcite and Fe-dolomite, calcite and quartz, calcite and aragonite with increasing concentrations of the dolomite, Fe-dolomite, quartz and aragonite up to 50% with step of 5%. Here we defined dependence of magnetic susceptibility from the porosity: the higher porosity measurements, the less slope of magnetic susceptibility, consequently mass magnetization is higher for diamagnetic and lower for paramagnetic carbonate rocks, but in the both cases magnetic susceptibility tries to reach zero with increasing of the total porosity. Rock measurements demonstrate that reservoir zones of the low diamagnetic magnetic susceptibility are generally correlated with higher permeability and also porosity distribution. However for different carbonate reservoirs we establish different relationships depending on the complexity of their mineralogy and texture. Application of integral understanding in distribution of permeability, porosity and mineral content in heterogeneous carbonates represented by this approach can be useful tool for carbonate reservoir

  6. Nanomaterial-assisted PCR based on thermal generation from magnetic nanoparticles under high-frequency AC magnetic fields

    NASA Astrophysics Data System (ADS)

    Higashi, Toshiaki; Minegishi, Hiroaki; Echigo, Akinobu; Nagaoka, Yutaka; Fukuda, Takahiro; Usami, Ron; Maekawa, Toru; Hanajiri, Tatsuro

    2015-08-01

    Here the authors present a nanomaterial-assisted PCR technique based on the use of thermal generation from magnetic nanoparticles (MNPs) under AC magnetic fields. In this approach, MNPs work as internal nano thermal generators to realize PCR thermal cycling. In order to suppress the non-specific absorption of DNA synthetic enzymes, MNPs are decorated with bovine serum albumin (BSA), forming BSA/MNP complexes. Under high-frequency AC magnetic fields, these complexes work as internal nano thermal generators, thereby producing the typical temperature required for PCR thermal cycling, and perform all the reaction processes of PCR amplification in the place of conventional PCR thermal cyclers.

  7. Extending Nuclear Magnetic Resonance Data for Permeability Estimation in Fine-Grained Sediments

    NASA Astrophysics Data System (ADS)

    Daigle, H.; Dugan, B.

    2008-12-01

    We developed a method for using nuclear magnetic resonance (NMR) T2 data and gamma ray data to estimate lithology-dependent permeability in silt- and clay-rich sediments. This model, based on the Schlumberger-Doll Research (SDR) model, allows for high resolution (<1 m) permeability estimates throughout a logged interval. Our model was calibrated using direct measurements on core samples from Keathley Canyon Lease Block 151 in the northern Gulf of Mexico. From NMR and gamma ray data we are able to determine permeability from 10-18 to 10-14 m2 (0.001 to 10 millidarcies). Thus from discrete core samples and log data we were able to develop a permeability model for the entire sedimentary column (425 m). Lithologic variation was incorporated into the model by varying the A coefficient based on the gamma ray response. This provides a more accurate permeability model than assigning a constant value to A as is typically done. The relationship between A and intrinsic lithologic properties is unclear; simple pore system models suggest that A may be related to specific surface, tortuosity, and pore structure; we investigate simple models to quantify how these properties vary with sediment consolidation and what their relationship is to A. A comprehensive understanding that links NMR data and A to pore-scale properties will provide new constraints on deformation and flow in porous systems, and will contribute to our understanding of sediment properties for fluid flow modeling at local and regional scales.

  8. Steinmetz law for ac magnetized iron-phenolformaldehyde resin soft magnetic composites

    NASA Astrophysics Data System (ADS)

    Kollár, Peter; Olekšáková, Denisa; Vojtek, Vladimír; Füzer, Ján; Fáberová, Mária; Bureš, Radovan

    2017-02-01

    The validity of the Steinmetz law, describing the total energy losses as a function of maximum induction from 0.1 to 1.2 T has been verified in the frequency range from 100 Hz to 1.2 kHz for iron-based soft magnetic composites (SMCs), with the aim to determine the coefficients in Steinmetz law. The Bertotti's statistical model was used to modify the Steinmetz law, for the hysteresis energy loss Wdc of SMCs magnetized in dc magnetic field, to the model for total energy losses Wt when an ac magnetic field is applied. In this case the total energy losses Wt consist of hysteresis losses to which the dynamic energy losses Wd, consisting of interparticle eddy current losses Wc inter, intraparticle eddy current losses Wc intra and excess losses We, were added. The validity of this model was experimentally proven for the investigated Fe-based SMCs at maximum inductions Bm ranging from 0.1 to 1.2 T.

  9. Huge ac magnetoresistance of La0.7Sr0.3MnO3 in sub-kilogauss magnetic fields

    NASA Astrophysics Data System (ADS)

    Mahendiran, Ramanathan; Rebello, Alwyn; Naik, Vinayak B.; Barik, Sujit Kumar

    2010-03-01

    We report radio frequency (f = 0.1 5 MHz) magnetotransport of La0.7Sr0.3MnO3 in sub kilogauss magnetic fields (H = 0-1 kG). We measured ac resistance (R) and reactance (X) simultaneously. In zero field, R decreases smoothly around the Curie temperature TC when f = 100 kHz, but it increases abruptly and shows a peak close to TC for f = 0.5-5 MHz. The peak decreases in amplitude, broadens and shifts downward in temperature as the bias field increases. The peak is completely suppressed under Hdc = 1 kOe when f = 0.5 MHz. A huge low-field ac magnetoresistance (δR/R = 40 %) and magnetoinductance (δX/X = 12 %) are found in a field of Hdc = 700 Oe and f = 2 MHz. We suggest that the observed ac magnetoresistance arises from the suppression of ac permeability and enhanced magnetic skin depth under a magnetic field. The dynamical magnetotransport reported here will be interesting from view points of fundamental physics and applications.

  10. In vitro cytotoxicity of Selol-loaded magnetic nanocapsules against neoplastic cell lines under AC magnetic field activation

    NASA Astrophysics Data System (ADS)

    Falqueiro, A. M.; Siqueira-Moura, M. P.; Jardim, D. R.; Primo, F. L.; Morais, P. C.; Mosiniewicz-Szablewska, E.; Suchocki, P.; Tedesco, A. C.

    2012-04-01

    The goals of this study are to evaluate invitro compatibility of magnetic nanomaterials and their therapeutic potential against cancer cells. Highly stable ionic magnetic fluid sample (maghemite, γ-Fe2O3) and Selol were incorporated into polymeric nanocapsules by nanoprecipitation method. The cytotoxic effect of Selol-loaded magnetic nanocapsules was assessed on murine melanoma (B16-F10) and oral squamous cell carcinoma (OSCC) cell lines following AC magnetic field application. The influence of different nanocapsules on cell viability was investigated by colorimetric MTT 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide assay. In the absence of AC magnetic field Selol-loaded magnetic nanocapsules, containing 100 µg/mL Selol plus 5 × 1012 particle/mL, showed antitumoral activity of about 50% on B16-F10 melanoma cells while OSCC carcinoma cells demonstrated drug resistance at all concentrations of Selol and magnetic fluid (range of 100-500 µg/mL Selol and 5 × 1012-2.5 × 1013 particle/mL). On the other hand, under AC applied fields (1 MHz and 40 Oe amplitude) B16-F10 cell viability was reduced down to 40.5% (±3.33) at the highest concentration of nanoencapsulated Selol. The major effect, however, was observed on OSCC cells since the cell viability drops down to about 33.3% (±0.38) under application of AC magnetic field. These findings clearly indicate that the Selol-loaded magnetic nanocapsules present different toxic effects on neoplastic cell lines. Further, the cytotoxic effect was maximized under AC magnetic field application on OSCC, which emphasizes the effectiveness of the magnetohyperthermia approach.

  11. Electric tuning of magnetization dynamics and electric field-induced negative magnetic permeability in nanoscale composite multiferroics.

    PubMed

    Jia, Chenglong; Wang, Fenglong; Jiang, Changjun; Berakdar, Jamal; Xue, Desheng

    2015-06-09

    Steering magnetism by electric fields upon interfacing ferromagnetic (FM) and ferroelectric (FE) materials to achieve an emergent multiferroic response bears a great potential for nano-scale devices with novel functionalities. FM/FE heterostructures allow, for instance, the electrical manipulation of magnetic anisotropy via interfacial magnetoelectric (ME) couplings. A charge-mediated ME effect is believed to be generally weak and active in only a few angstroms. Here we present an experimental evidence uncovering a new magnon-driven, strong ME effect acting on the nanometer range. For Co92Zr8 (20 nm) film deposited on ferroelectric PMN-PT we show via ferromagnetic resonance (FMR) that this type of linear ME allows for electrical control of simultaneously the magnetization precession and its damping, both of which are key elements for magnetic switching and spintronics. The experiments unravel further an electric-field-induced negative magnetic permeability effect.

  12. Electric tuning of magnetization dynamics and electric field-induced negative magnetic permeability in nanoscale composite multiferroics

    NASA Astrophysics Data System (ADS)

    Jia, Chenglong; Wang, Fenglong; Jiang, Changjun; Berakdar, Jamal; Xue, Desheng

    2015-06-01

    Steering magnetism by electric fields upon interfacing ferromagnetic (FM) and ferroelectric (FE) materials to achieve an emergent multiferroic response bears a great potential for nano-scale devices with novel functionalities. FM/FE heterostructures allow, for instance, the electrical manipulation of magnetic anisotropy via interfacial magnetoelectric (ME) couplings. A charge-mediated ME effect is believed to be generally weak and active in only a few angstroms. Here we present an experimental evidence uncovering a new magnon-driven, strong ME effect acting on the nanometer range. For Co92Zr8 (20 nm) film deposited on ferroelectric PMN-PT we show via ferromagnetic resonance (FMR) that this type of linear ME allows for electrical control of simultaneously the magnetization precession and its damping, both of which are key elements for magnetic switching and spintronics. The experiments unravel further an electric-field-induced negative magnetic permeability effect.

  13. Electric tuning of magnetization dynamics and electric field-induced negative magnetic permeability in nanoscale composite multiferroics

    PubMed Central

    Jia, Chenglong; Wang, Fenglong; Jiang, Changjun; Berakdar, Jamal; Xue, Desheng

    2015-01-01

    Steering magnetism by electric fields upon interfacing ferromagnetic (FM) and ferroelectric (FE) materials to achieve an emergent multiferroic response bears a great potential for nano-scale devices with novel functionalities. FM/FE heterostructures allow, for instance, the electrical manipulation of magnetic anisotropy via interfacial magnetoelectric (ME) couplings. A charge-mediated ME effect is believed to be generally weak and active in only a few angstroms. Here we present an experimental evidence uncovering a new magnon-driven, strong ME effect acting on the nanometer range. For Co92Zr8 (20 nm) film deposited on ferroelectric PMN-PT we show via ferromagnetic resonance (FMR) that this type of linear ME allows for electrical control of simultaneously the magnetization precession and its damping, both of which are key elements for magnetic switching and spintronics. The experiments unravel further an electric-field-induced negative magnetic permeability effect. PMID:26058060

  14. Development and application of setup for ac magnetic field in neutron scattering experiments.

    PubMed

    Klimko, Sergey; Zhernenkov, Kirill; Toperverg, Boris P; Zabel, Hartmut

    2010-10-01

    We report on a new setup developed for neutron scattering experiments in periodically alternating magnetic fields at the sample position. The assembly consisting of rf generator, amplifier, wide band transformer, and resonance circuit. It allows to generate homogeneous ac magnetic fields over a volume of a few cm(3) and variable within a wide range of amplitudes and frequencies. The applicability of the device is exemplified by ac polarized neutron reflectometry (PNR): a new method established to probe remagnetization kinetics in soft ferromagnetic films. Test experiments with iron films demonstrate that the ac field within the accessible range of frequencies and amplitudes produces a dramatic effect on the PNR signal. This shows that the relevant ac field parameters generated by the device match well with the scales involved in the remagnetization processes. Other possible applications of the rf unit are briefly discussed.

  15. Nonlinear dynamics of Josephson vortices in a film screen under dc and ac magnetic fields

    NASA Astrophysics Data System (ADS)

    Sheikhzada, A.; Gurevich, A.

    2014-11-01

    We present detailed numerical simulations of Josephson vortices in a long Josephson junction perpendicular to a thin film screen under strong dc and ac magnetic fields. By solving the sine-Gordon equation, we calculated the threshold magnetic field for penetration of fluxons as a function of frequency, and the power dissipated by oscillating fluxons as functions of the ac field amplitude and frequency. We considered the effects of superimposed ac and dc fields, and a bi-harmonic magnetic field resulting in a vortex ratchet dynamics. The results were used to evaluate the contribution of weak-linked grain boundaries to the nonlinear surface resistance of polycrystalline superconductors under strong electromagnetic fields, particularly thin film screens and resonator cavities.

  16. Fiber - Optic Devices as Temperature Sensors for Temperature Measurements in AC Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Rablau, Corneliu; Lafrance, Joseph; Sala, Anca

    2007-10-01

    We report on the investigation of several fiber-optic devices as potential sensors for temperature measurements in AC magnetic fields. Common temperature sensors, such as thermocouples, thermistors or diodes, will create random and/or systematic errors when placed in a magnetic field. A DC magnetic field is susceptible to create a systematic offset to the measurement, while in an AC magnetic field of variable frequency random errors which cannot be corrected for can also be introduced. Fiber-Bragg-gratings and thin film filters have an inherent temperature dependence. Detrimental for their primary applications, the same dependence allows one to use such devices as temperature sensors. In an AC magnetic field, they present the advantage of being immune to electromagnetic interference. Moreover, for fiber-Bragg-gratings, the shape factor and small mass of the bare-fiber device make it convenient for temperature measurements on small samples. We studied several thin-film filters and fiber-Bragg-gratings and compared their temperature measurement capabilities in AC magnetic fields of 0 to 150 Gauss, 0 to 20 KHz to the results provided by off-the-shelf thermocouples and thermistor-based temperature measurement systems.

  17. AC loss evaluation of an HTS insert for high field magnet cooled by cryocoolers

    NASA Astrophysics Data System (ADS)

    Kajikawa, Kazuhiro; Awaji, Satoshi; Watanabe, Kazuo

    2016-12-01

    AC losses in a high temperature superconducting (HTS) insert coil for 25-T cryogen-free superconducting magnet during its initial energization are numerically calculated under the assumption of slab approximation. The HTS insert consisting of 68 single pancakes wound using coated conductors generates a central magnetic field of 11.5 T in addition to the contribution of 14.0 T from a set of low temperature superconducting (LTS) outsert coils. Both the HTS insert and the LTS coils are cooled using cryocoolers, and energized simultaneously up to the central field of 25.5 T with a constant ramp rate for 60 min. The influences of the magnitudes and orientations of locally applied magnetic fields, magnetic interactions between turns and transport currents flowing in the windings are taken into account in the calculations of AC losses. The locally applied fields are separated into axial and radial components, and the individual contributions of these field components to the AC losses are simply summed up to obtain the total losses. The AC losses due to the axial fields become major in the beginning of energization, whereas the total losses monotonically increase with time after the AC losses due to the radial fields become major.

  18. ac current generation in chiral magnetic insulators and Skyrmion motion induced by the spin Seebeck effect.

    PubMed

    Lin, Shi-Zeng; Batista, Cristian D; Reichhardt, Charles; Saxena, Avadh

    2014-05-09

    We show that a temperature gradient induces an ac electric current in multiferroic insulators when the sample is embedded in a circuit. We also show that a thermal gradient can be used to move magnetic Skyrmions in insulating chiral magnets: the induced magnon flow from the hot to the cold region drives the Skyrmions in the opposite direction via a magnonic spin transfer torque. Both results are combined to compute the effect of Skyrmion motion on the ac current generation and demonstrate that Skyrmions in insulators are a promising route for spin caloritronics applications.

  19. Calorimetric method of ac loss measurement in a rotating magnetic field.

    PubMed

    Ghoshal, P K; Coombs, T A; Campbell, A M

    2010-07-01

    A method is described for calorimetric ac-loss measurements of high-T(c) superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines.

  20. Calorimetric method of ac loss measurement in a rotating magnetic field

    SciTech Connect

    Ghoshal, P. K.; Coombs, T. A.; Campbell, A. M.

    2010-07-15

    A method is described for calorimetric ac-loss measurements of high-T{sub c} superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines.

  1. Calorimetric method of ac loss measurement in a rotating magnetic field

    NASA Astrophysics Data System (ADS)

    Ghoshal, P. K.; Coombs, T. A.; Campbell, A. M.

    2010-07-01

    A method is described for calorimetric ac-loss measurements of high-Tc superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines.

  2. A multifrequency eletromagnetic applicator with an integrated AC magnetometer for magnetic hyperthermia experiments

    NASA Astrophysics Data System (ADS)

    Garaio, E.; Collantes, J. M.; Plazaola, F.; Garcia, J. A.; Castellanos-Rubio, I.

    2014-11-01

    In the present paper, a lab-made electromagnetic applicator for magnetic hyperthermia experiments is described, fabricated and tested. The proposed device is able to measure the specific absorption rate (SAR) of nanoparticle samples at different magnetic field intensities and frequencies. Based on a variable parallel LCC resonant circuit fed by a linear power amplifier, the electromagnetic applicator is optimized to generate a controllable and homogeneous AC magnetic field in a 3.5 cm3 cylindrical volume, in a wide frequency range of 149-1030 kHz with high field intensities (up to 35 kA m-1 at low frequencies and up to 22 kA m-1 at high frequencies). In addition, a lab-made AC magnetometer is integrated in the electromagnetic applicator. The AC magnetometer is fully compensated to provide accurate measurements of the dynamic hysteresis cycle for nanoparticle powders or dispersions. From these dynamic hysteresis loops the SAR of the nanoparticle samples can be directly obtained. To show the capabilities of the proposed set-up, the AC hysteresis loops of two different magnetite nanoparticle samples with different sizes have been measured for various field intensities and frequencies. To our knowledge, no other work reports an electromagnetic applicator system with integrated AC magnetometer providing such characteristics in terms of frequency and intensity.

  3. Measurements of AC Loss In Second-Generation HTS Tapes in a DC Magnetic Field

    NASA Astrophysics Data System (ADS)

    Osofsky, M. S.; Soulen, R. J.; Gubser, D. U.; Datta, T.

    2008-03-01

    The successful application of superconductivity to motors and other power system components depends on the characterization and subsequent minimization of the ac loss in the superconductor used for fabrication of the component. The superconductive component, excited by an ac power source, may be exposed to large dc magnetic fields and/or ac fields. To further complicate the situation, the transport properties of the tapes are strongly dependent on the angle between the applied field and the YBCO c-axis (normal to the tape surface). We report on measurements of the transport ac loss of a YBaCuO tape at 65 K, at several frequencies, in applied dc fields of 1-3 T with the field parallel and perpendicular to the tape normal.

  4. A Miniature Magnetic-Force-Based Three-Axis AC Magnetic Sensor with Piezoelectric/Vibrational Energy-Harvesting Functions.

    PubMed

    Hung, Chiao-Fang; Yeh, Po-Chen; Chung, Tien-Kan

    2017-02-08

    In this paper, we demonstrate a miniature magnetic-force-based, three-axis, AC magnetic sensor with piezoelectric/vibrational energy-harvesting functions. For magnetic sensing, the sensor employs a magnetic-mechanical-piezoelectric configuration (which uses magnetic force and torque, a compact, single, mechanical mechanism, and the piezoelectric effect) to convert x-axis and y-axis in-plane and z-axis magnetic fields into piezoelectric voltage outputs. Under the x-axis magnetic field (sine-wave, 100 Hz, 0.2-3.2 gauss) and the z-axis magnetic field (sine-wave, 142 Hz, 0.2-3.2 gauss), the voltage output with the sensitivity of the sensor are 1.13-26.15 mV with 8.79 mV/gauss and 1.31-8.92 mV with 2.63 mV/gauss, respectively. In addition, through this configuration, the sensor can harness ambient vibrational energy, i.e., possessing piezoelectric/vibrational energy-harvesting functions. Under x-axis vibration (sine-wave, 100 Hz, 3.5 g) and z-axis vibration (sine-wave, 142 Hz, 3.8 g), the root-mean-square voltage output with power output of the sensor is 439 mV with 0.333 μW and 138 mV with 0.051 μW, respectively. These results show that the sensor, using this configuration, successfully achieves three-axis magnetic field sensing and three-axis vibration energy-harvesting. Due to these features, the three-axis AC magnetic sensor could be an important design reference in order to develop future three-axis AC magnetic sensors, which possess energy-harvesting functions, for practical industrial applications, such as intelligent vehicle/traffic monitoring, processes monitoring, security systems, and so on.

  5. AC losses in perpendicular external magnetic fields in ring bundle barrier multifilamentary BSCCO(2223) tapes with a central resistive barrier

    NASA Astrophysics Data System (ADS)

    Eckelmann, H.; Krelaus, J.; Nast, R.; Goldacker, W.

    2001-06-01

    For the most common AC frequencies, the main components of the AC losses in multifilamentary Bi(2223) tapes are caused by both hysteresis and coupling losses. These losses can be reduced by increasing the matrix resistivity, applying a twist to the filaments and by the use of a conductor design optimised for a practical application. In the ring bundle barrier (RBB) conductor design we have bundles of filaments which are twisted around a central resistive core. The RBB structure was prepared via the powder in tube assemble and react (PITAR) route . In these tapes six bundles of seven filaments are twisted around a resistive layer of a mixture of 50% SrCO 3 and 50% SrZrO 3 in the centre of the tape. A series of tapes with twist lengths down to 3.4 mm was prepared. We present the measured AC losses of these tapes in external perpendicular magnetic fields. By using existing models, a description of the losses in the low Ḃ range was possible, leading to a separation into hysteresis, eddy current and coupling current losses. The frequency dependent loss contribution is dominated by the coupling current losses, from which the coupling current decay time constant, the effective permeability, the matrix resistivity and the critical Ḃc for filament coupling were extracted. In tapes with a twist length below 5 mm the typical loss behaviour for decoupled filaments is observed at frequencies up to 500 Hz. Compared to the untwisted tapes, a loss reduction of up to 70% for low field amplitudes (below 10 mT) was achieved.

  6. Quantitatively probing the magnetic behavior of individual nanoparticles by an AC field-modulated magnetic force microscopy.

    PubMed

    Li, Xiang; Lu, Wei; Song, Yiming; Wang, Yuxin; Chen, Aiying; Yan, Biao; Yoshimura, Satoru; Saito, Hitoshi

    2016-03-02

    Despite decades of advances in magnetic imaging, obtaining direct, quantitative information with nanometer scale spatial resolution remains an outstanding challenge. Current approaches, for example, Hall micromagnetometer and nitrogen-vacancy magnetometer, are limited by highly complex experimental apparatus and a dedicated sample preparation process. Here we present a new AC field-modulated magnetic force microscopy (MFM) and report the local and quantitative measurements of the magnetic information of individual magnetic nanoparticles (MNPs), which is one of the most iconic objects of nanomagnetism. This technique provides simultaneously a direct visualization of the magnetization process of the individual MNPs, with spatial resolution and magnetic sensitivity of about 4.8 nm and 1.85 × 10(-20) A m(2), respectively, enabling us to separately estimate the distributions of the dipolar fields and the local switching fields of individual MNPs. Moreover, we demonstrate that quantitative magnetization moment of individual MNPs can be routinely obtained using MFM signals. Therefore, it underscores the power of the AC field-modulated MFM for biological and biomedical applications of MNPs and opens up the possibility for directly and quantitatively probing the weak magnetic stray fields from nanoscale magnetic systems with superior spatial resolution.

  7. Quantitatively probing the magnetic behavior of individual nanoparticles by an AC field-modulated magnetic force microscopy

    PubMed Central

    Li, Xiang; Lu, Wei; Song, Yiming; Wang, Yuxin; Chen, Aiying; Yan, Biao; Yoshimura, Satoru; Saito, Hitoshi

    2016-01-01

    Despite decades of advances in magnetic imaging, obtaining direct, quantitative information with nanometer scale spatial resolution remains an outstanding challenge. Current approaches, for example, Hall micromagnetometer and nitrogen-vacancy magnetometer, are limited by highly complex experimental apparatus and a dedicated sample preparation process. Here we present a new AC field-modulated magnetic force microscopy (MFM) and report the local and quantitative measurements of the magnetic information of individual magnetic nanoparticles (MNPs), which is one of the most iconic objects of nanomagnetism. This technique provides simultaneously a direct visualization of the magnetization process of the individual MNPs, with spatial resolution and magnetic sensitivity of about 4.8 nm and 1.85 × 10−20 A m2, respectively, enabling us to separately estimate the distributions of the dipolar fields and the local switching fields of individual MNPs. Moreover, we demonstrate that quantitative magnetization moment of individual MNPs can be routinely obtained using MFM signals. Therefore, it underscores the power of the AC field-modulated MFM for biological and biomedical applications of MNPs and opens up the possibility for directly and quantitatively probing the weak magnetic stray fields from nanoscale magnetic systems with superior spatial resolution. PMID:26932357

  8. Quantitatively probing the magnetic behavior of individual nanoparticles by an AC field-modulated magnetic force microscopy

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Lu, Wei; Song, Yiming; Wang, Yuxin; Chen, Aiying; Yan, Biao; Yoshimura, Satoru; Saito, Hitoshi

    2016-03-01

    Despite decades of advances in magnetic imaging, obtaining direct, quantitative information with nanometer scale spatial resolution remains an outstanding challenge. Current approaches, for example, Hall micromagnetometer and nitrogen-vacancy magnetometer, are limited by highly complex experimental apparatus and a dedicated sample preparation process. Here we present a new AC field-modulated magnetic force microscopy (MFM) and report the local and quantitative measurements of the magnetic information of individual magnetic nanoparticles (MNPs), which is one of the most iconic objects of nanomagnetism. This technique provides simultaneously a direct visualization of the magnetization process of the individual MNPs, with spatial resolution and magnetic sensitivity of about 4.8 nm and 1.85 × 10‑20 A m2, respectively, enabling us to separately estimate the distributions of the dipolar fields and the local switching fields of individual MNPs. Moreover, we demonstrate that quantitative magnetization moment of individual MNPs can be routinely obtained using MFM signals. Therefore, it underscores the power of the AC field-modulated MFM for biological and biomedical applications of MNPs and opens up the possibility for directly and quantitatively probing the weak magnetic stray fields from nanoscale magnetic systems with superior spatial resolution.

  9. Experimental study of the AC magnetization loss in MgB2 superconducting wires at different temperatures

    NASA Astrophysics Data System (ADS)

    Kováč, Ján; Šouc, Ján; Kováč, Pavol

    2012-05-01

    The temperature and external AC magnetic field dependence of AC magnetization losses of MgB2 wires were studied. Temperature was varied from 18 K to 40 K and external magnetic field of frequencies 72 Hz and 144 Hz from 8 mT to 70 mT with orientation perpendicular to the wire axis. To clarify the influence of the wire construction on AC loss, single and six filament untwisted samples of length ∼50 mm were examined. For this purpose unique experimental apparatus created by the combination of original calibration-free measuring system designed for ac magnetization loss measurement and non-magnetic vacuum vessel with two-stage cryocooler for sample cooling was used. It was found, that for monofilament sample hysteretic AC losses was dominated in comparison to untwisted six-filaments sample, where coupling losses confirmed by frequency dependence were dominated.

  10. A Miniature Magnetic-Force-Based Three-Axis AC Magnetic Sensor with Piezoelectric/Vibrational Energy-Harvesting Functions

    PubMed Central

    Hung, Chiao-Fang; Yeh, Po-Chen; Chung, Tien-Kan

    2017-01-01

    In this paper, we demonstrate a miniature magnetic-force-based, three-axis, AC magnetic sensor with piezoelectric/vibrational energy-harvesting functions. For magnetic sensing, the sensor employs a magnetic–mechanical–piezoelectric configuration (which uses magnetic force and torque, a compact, single, mechanical mechanism, and the piezoelectric effect) to convert x-axis and y-axis in-plane and z-axis magnetic fields into piezoelectric voltage outputs. Under the x-axis magnetic field (sine-wave, 100 Hz, 0.2–3.2 gauss) and the z-axis magnetic field (sine-wave, 142 Hz, 0.2–3.2 gauss), the voltage output with the sensitivity of the sensor are 1.13–26.15 mV with 8.79 mV/gauss and 1.31–8.92 mV with 2.63 mV/gauss, respectively. In addition, through this configuration, the sensor can harness ambient vibrational energy, i.e., possessing piezoelectric/vibrational energy-harvesting functions. Under x-axis vibration (sine-wave, 100 Hz, 3.5 g) and z-axis vibration (sine-wave, 142 Hz, 3.8 g), the root-mean-square voltage output with power output of the sensor is 439 mV with 0.333 μW and 138 mV with 0.051 μW, respectively. These results show that the sensor, using this configuration, successfully achieves three-axis magnetic field sensing and three-axis vibration energy-harvesting. Due to these features, the three-axis AC magnetic sensor could be an important design reference in order to develop future three-axis AC magnetic sensors, which possess energy-harvesting functions, for practical industrial applications, such as intelligent vehicle/traffic monitoring, processes monitoring, security systems, and so on. PMID:28208693

  11. Magnetic field effects for copper suspended nanofluid venture through a composite stenosed arteries with permeable wall

    NASA Astrophysics Data System (ADS)

    Akbar, Noreen Sher; Butt, Adil Wahid

    2015-05-01

    In the present paper magnetic field effects for copper nanoparticles for blood flow through composite stenosis in arteries with permeable wall are discussed. The copper nanoparticles for the blood flow with water as base fluid is not explored yet. The equations for the Cu-water nanofluid are developed first time in the literature and simplified using long wavelength and low Reynolds number assumptions. Exact solutions have been evaluated for velocity, pressure gradient, the solid volume fraction of the nanoparticles and temperature profile. The effect of various flow parameters on the flow and heat transfer characteristics is utilized.

  12. Characterization of tumor microvascular structure and permeability: comparison between magnetic resonance imaging and intravital confocal imaging

    NASA Astrophysics Data System (ADS)

    Reitan, Nina Kristine; Thuen, Marte; Goa, Pa˚L. Erik; de Lange Davies, Catharina

    2010-05-01

    Solid tumors are characterized by abnormal blood vessel organization, structure, and function. These abnormalities give rise to enhanced vascular permeability and may predict therapeutic responses. The permeability and architecture of the microvasculature in human osteosarcoma tumors growing in dorsal window chambers in athymic mice were measured by confocal laser scanning microscopy (CLSM) and dynamic contrast enhanced magnetic resonance imaging (DCE-MRI). Dextran (40 kDa) and Gadomer were used as molecular tracers for CLSM and DCE-MRI, respectively. A significant correlation was found between permeability indicators. The extravasation rate Ki as measured by CLSM correlated positively with DCE-MRI parameters, such as the volume transfer constant Ktrans and the initial slope of the contrast agent concentration-time curve. This demonstrates that these two techniques give complementary information. Extravasation was further related to microvascular structure and was found to correlate with the fractal dimension and vascular density. The structural parameter values that were obtained from CLSM images were higher for abnormal tumor vasculature than for normal vessels.

  13. Optical transmission versus ac magnetization measurements for monitoring colloidal Ni nanorod rotational dynamics

    NASA Astrophysics Data System (ADS)

    Gratz, M.; Tschöpe, A.

    2017-01-01

    Ni nanorods with an average length < 250 nm and diameter < 30 nm were synthesized using the AAO template method. The magnetization and optical transmission of nanorod colloidal dispersions in alternating magnetic fields were measured and analyzed with the objective of comparing the intrinsic Brownian relaxation times obtained with the two methods. The different physical origin of the measured signal, related to different moments of the orientation distribution function, and the non-linear effects expected for the large magnetic moments of the Ni nanorods at common field amplitudes required a comprehensive modelling. The time-dependent magnetization and optical transmission in ac magnetic fields was derived by numerical solution of the Fokker-Planck equation. The simulated time-dependent magnetization and optical transmission at a given frequency and field amplitude were analyzed analogous to experimental data to determine characteristic relaxation frequencies. Empirical relationships were derived which enabled extraction of the intrinsic Brownian relaxation time from the characteristic frequencies measured in the non-linear regime. Despite large differences in the characteristic frequencies obtained from magnetization and optical transmission measurements, the retrieved intrinsic Brownian relaxation times were found to agree well. The potential of ac magnetic field-dependent optical transmission for biosensing applications was demonstrated by monitoring the adsorption of the protein gelatine on the nanorod labels.

  14. A self-powered AC magnetic sensor based on piezoelectric nanogenerator.

    PubMed

    Yu, Aifang; Song, Ming; Zhang, Yan; Kou, Jinzong; Zhai, Junyi; Lin Wang, Zhong

    2014-11-14

    An AC magnetic field, which is a carrier of information, is distributed everywhere and is continuous. How to use and detect this field has been an ongoing topic over the past few decades. Conventional magnetic sensors are usually based on the Hall Effect, the fluxgate, a superconductor quantum interface or magnetoelectric or magnetoresistive sensing. Here, a flexible, simple, low-cost and self-powered active piezoelectric nanogenerator (NG) is successfully demonstrated as an AC magnetic field sensor at room temperature. The amplitude and frequency of a magnetic field can both be accurately sensed by the NG. The output voltage of the NG has a good linearity with a measured magnetic field. The detected minute magnetic field is as low as 1.2 × 10(-7) tesla, which is 400 times greater than a commercial magnetic sensor that uses the Hall Effect. In comparison to the existing technologies, an NG is a room-temperature self-powered active sensor that is very simple and very cheap for practical applications.

  15. Influence of 50 Hz frequency sinusoidal magnetic field on the blood-brain barrier permeability of diabetic rats.

    PubMed

    Oztaş, Baria; Kalkan, Tunaya; Tuncel, Handan

    2004-07-01

    The combined effects of diabetes and a 50 Hz, 5 mT RMS flux density sinusoidal magnetic field for 8 h a day, for 21 consecutive days on the permeation of Evans-blue dye through the blood-brain barrier were studied in male Wistar albino rats. Our results suggest that magnetic field has no effect on the blood-brain barrier permeability in normoglycemic animals, but that diabetic rats are vulnerable to magnetic fields.

  16. Artificial permeability and antibonding magnetic resonance in a copper-structured metamaterial with symmetry-broken ring-plate resonators.

    PubMed

    Wang, Y K; Dong, Z G; Zhai, Y

    2012-08-01

    We numerically investigate the antibonding magnetic resonance in a metamaterial composed of rings and plates, with a particular attention to the influence of broken structural symmetry on the Fano-type transmission spectrum as well as the resonant artificial permeability. From the simulation results, it is obvious that the antibonding magnetic resonance with strong magnetic-dipole coupling is responsible for the Fano-type profile, since an increase of the structural asymmetry extent to reduce the magnetic field confinement in one of the gaps will form, in contrary, a Lorentzian resonance dip. The dual excitation pathways, i.e., electric and magnetic resonances, at destructive interference are the underlying reason of the Fano-type transmission response. Additionally, the structural-asymmetry dependence of the artificial permeability shows that the broken symmetry can strongly modify the effective permeability due to the altering magnetic-dipole interactions. It is found that an anti-resonant curve of permeability versus frequency will be resulted in if significant symmetry-broken structure is introduced.

  17. Super-resolution high sensitivity AC Magnetic Field Imaging with NV Centers in Diamond

    NASA Astrophysics Data System (ADS)

    Bauch, Erik; Jaskula, Jean-Christophe; Trifonov, Alexei; Walsworth, Ronald

    2015-05-01

    The Nitrogen-Vacancy center in diamond (NV center), a defect consisting of a nitrogen atom next to a missing atom, has been successfully applied to sense magnetic field, electric field, temperature and can also be used as fluorescence marker and single photon emitter. We will present super-resolution imaging of NV centers and simultaneous sensing of AC magnetic fields with high sensitivity. To demonstrate the applicability of super-resolution magnetic field imaging, we resolve several NV centers with an optical resolution smaller than 20 nm and probe locally the gradient of a externally applied magnetic field. Additionally, we demonstrate the detection of magnetic field signals from 1H protons with subdiffraction image resolution. We will also show that our super-resolution magnetometer will benefit from a new readout method based on a spin-to-charge mapping that we have developed to increase the readout contrast.

  18. Redesign of an AC Magnetic Susceptometer for Measurements in Smaller Samples

    NASA Astrophysics Data System (ADS)

    Vargas, Andres; Fukuda, Ryan; Sunny, Smitha; Ho, Pei-Chun

    2013-03-01

    A new AC magnetic susceptometer was created for the purpose of measuring the magnetic properties of smaller samples, such as nanoparticles that are currently being synthesized in our lab. The susceptometer consists of a primary coil, a secondary coil, and a sample holder. The primary coil is the outer component of the susceptometer, which provides a magnetic field when current is applied due to Ampere's Law. Inside of the primary coil lies the secondary coil, which has two oppositely wound solenoids; they are oppositely wound to reduce background signal. The sample holder lies inside of the secondary coil with the sample. All of these go inside of a beryllium copper casing for protection. We tested the susceptometer by looking for the ferromagnetic phase transition of an 11 mg Gd sample. A ~ 100 μ A AC current was applied to the primary coil, which created a magnetic field that polarized the magnetic moments in the sample. This induced a voltage on the secondary coil, which is proportional to the magnetic susceptibility. We measured the temperature dependency of the induced voltage from 10 K to 300 K. The results showed a sharp increase in the induced voltage around 293K, which agrees with the known ferromagnetic transition of Gd. Research at CSU-Fresno is supported by NSF DMR-1104544. Felipe Vargas is also supported by Undergraduate Research Grant and Faculty-Sponsored Student Research Award at CSU Fresno.

  19. Metamaterials and the Landau-Lifshitz permeability argument: large permittivity begets high-frequency magnetism.

    PubMed

    Merlin, Roberto

    2009-02-10

    Homogeneous composites, or metamaterials, made of dielectric or metallic particles are known to show magnetic properties that contradict arguments by Landau and Lifshitz [Landau LD, Lifshitz EM (1960) Electrodynamics of Continuous Media (Pergamon, Oxford, UK), p 251], indicating that the magnetization and, thus, the permeability, loses its meaning at relatively low frequencies. Here, we show that these arguments do not apply to composites made of substances with Im square root(epsilon(S)) > lambda/l or Re square root(epsilon(S)) approximately lambda/l (epsilon(S) and l are the complex permittivity and the characteristic length of the particles, and lambda > l is the vacuum wavelength). Our general analysis is supported by studies of split rings, one of the most common constituents of electromagnetic metamaterials, and spherical inclusions. An analytical solution is given to the problem of scattering by a small and thin split ring of arbitrary permittivity. Results reveal a close relationship between epsilon(S) and the dynamic magnetic properties of metamaterials. For |square root(epsilon(S))| < lambda/a (a is the ring cross-sectional radius), the composites exhibit very weak magnetic activity, consistent with the Landau-Lifshitz argument and similar to that of molecular crystals. In contrast, large values of the permittivity lead to strong diamagnetic or paramagnetic behavior characterized by susceptibilities whose magnitude is significantly larger than that of natural substances. We compiled from the literature a list of materials that show high permittivity at wavelengths in the range 0.3-3000 microm. Calculations for a system of spherical inclusions made of these materials, using the magnetic counterpart to Lorentz-Lorenz formula, uncover large magnetic effects the strength of which diminishes with decreasing wavelength.

  20. Improved Dynamic Response of Magnetic Feedback in DIII-D with AC Compensation

    NASA Astrophysics Data System (ADS)

    Piron, Lidia; Marrelli, Lionello; Martin, Piero; Piovesan, Paolo; Soppelsa, Anton; Hanson, Jeremy; Reimerdes, Holger; in, Yongkyoon; Okabayashi, Michio

    2010-11-01

    High-β tokamaks need robust magnetic feedback to cope with various MHD modes. A new algorithm was tested to improve the DIII-D feedback dynamic response. Magnetic sensor signals include contributions from vacuum sources, such as active coils. In the present algorithm, the plasma response to an applied field is computed by subtracting from the sensor signals the dc component of couplings to the coils. But, when the coil currents vary on fast enough time scales, wall eddy currents modify the contributions to the sensor field with respect to its dc value [1]. Such ac effects can be non-negligible. Transfer functions between coils and sensors were measured and an ac compensation scheme accounting for them was developed. Significant coil current was saved likely due to a better estimate of the plasma response. Ac effects may be more important at high-β, where uncorrected error fields are strongly amplified. [1] E.J. Strait et al. 2003 Nucl. Fusion 43 430. *Work supported in part by US DOE under by DE-FG02-04ER54761, DE-FG02-06ER84442, & DE-AC02-09CH11466.

  1. Magnetization AC losses in MgB2 wires made by IMD process

    NASA Astrophysics Data System (ADS)

    Kováč, J.; Šouc, J.; Kováč, P.; Hušek, I.

    2015-01-01

    Magnetization AC losses of MgB2 superconductors with one and four filaments made by an internal magnesium diffusion (IMD) into boron process were measured and analyzed. For AC loss measurement a system based on a calibration-free method was used. Short samples of MgB2 wires were exposed to an external magnetic field with amplitudes up to 0.07 T, frequencies up to 1200 Hz, and a temperature range between 15 K and 40 K. A strong effect of eddy current losses was found in single-core wire containing pure copper sheath, which was proved by the same wire measurement after Cu etching. The impact of coupling current losses in non-twisted four-filament wire and the decoupling effect after twisting were observed. Coupling current losses in a low-frequency region were effectively reduced in agreement with theoretical assumption. The degradation of transport currents due to torsion stress by twisting was taken into account and the normalized AC losses of MgB2 wires made by IMD and powder-in-tube processes were compared. It appears that the IMD process is more perspective for AC applications due to much higher current densities and smaller degradation of current-carrying capability by twisting.

  2. Enhancing the spin transfer torque in magnetic tunnel junctions by ac modulation

    NASA Astrophysics Data System (ADS)

    Chen, Xiaobin; Zhou, Chenyi; Zhang, Zhaohui; Chen, Jingzhe; Zheng, Xiaohong; Zhang, Lei; Hu, Can-Ming; Guo, Hong

    2017-03-01

    The phenomenon of spin transfer torque (STT) has attracted a great deal of interest due to its promising prospects in practical spintronic devices. In this paper, we report a theoretical investigation of STT in a noncollinear magnetic tunnel junction under ac modulation based on the nonequilibrium Green's-function formalism, and we derive a closed formulation for predicting the time-averaged STT. Using this formulation, the ac STT of a carbon-nanotube-based magnetic tunnel junction is analyzed. Under ac modulation, the low-bias linear (quadratic) dependence of the in-plane (out-of-plane) torque on bias still holds, and the sinθ dependence on the noncollinear angle is maintained. By photon-assisted tunneling, the bias-induced components of the in-plane and out-of-plane torques can be enhanced significantly, about 12 and 75 times, respectively. Our analysis reveals the condition for achieving optimized STT enhancement and suggests that ac modulation is a very effective way for electrical manipulation of STT.

  3. Late gadolinium enhanced cardiovascular magnetic resonance of lamin A/C gene mutation related dilated cardiomyopathy

    PubMed Central

    2011-01-01

    Background The purpose of this study was to identify early features of lamin A/C gene mutation related dilated cardiomyopathy (DCM) with cardiovascular magnetic resonance (CMR). We characterise myocardial and functional findings in carriers of lamin A/C mutation to facilitate the recognition of these patients using this method. We also investigated the connection between myocardial fibrosis and conduction abnormalities. Methods Seventeen lamin A/C mutation carriers underwent CMR. Late gadolinium enhancement (LGE) and cine images were performed to evaluate myocardial fibrosis, regional wall motion, longitudinal myocardial function, global function and volumetry of both ventricles. The location, pattern and extent of enhancement in the left ventricle (LV) myocardium were visually estimated. Results Patients had LV myocardial fibrosis in 88% of cases. Segmental wall motion abnormalities correlated strongly with the degree of enhancement. Myocardial enhancement was associated with conduction abnormalities. Sixty-nine percent of our asymptomatic or mildly symptomatic patients showed mild ventricular dilatation, systolic failure or both in global ventricular analysis. Decreased longitudinal systolic LV function was observed in 53% of patients. Conclusions Cardiac conduction abnormalities, mildly dilated LV and depressed systolic dysfunction are common in DCM caused by a lamin A/C gene mutation. However, other cardiac diseases may produce similar symptoms. CMR is an accurate tool to determine the typical cardiac involvement in lamin A/C cardiomyopathy and may help to initiate early treatment in this malignant familiar form of DCM. PMID:21689390

  4. Why an ac magnetic field shifts the irreversibility line in type-II superconductors.

    PubMed

    Brandt, Ernst Helmut; Mikitik, Grigorii P

    2002-07-08

    We show that for a thin superconducting strip placed in a transverse dc magnetic field--the typical geometry of experiments with high-T(c) superconductors--the application of a weak ac magnetic field perpendicular to the dc field generates a dc voltage in the strip. This voltage leads to the decay of the critical currents circulating in the strip, and eventually the equilibrium state of the superconductor is established. This relaxation is not due to thermally activated flux creep but to the "walking" motion of vortices in the two-dimensional critical state of the strip with in-plane ac field. Our theory explains the shaking effect that was used for detecting phase transitions of the vortex lattice in superconductors.

  5. Advanced AC permanent magnet axial flux disc motor for electric passenger vehicle

    NASA Technical Reports Server (NTRS)

    Kliman, G. B.

    1982-01-01

    An ac permanent magnet axial flux disc motor was developed to operate with a thyristor load commutated inverter as part of an electric vehicle drive system. The motor was required to deliver 29.8 kW (40 hp) peak and 10.4 kW (14 hp) average with a maximum speed of 11,000 rpm. It was also required to run at leading power factor to commutate the inverter. Three motors were built.

  6. On the origin of magnetic a.c. susceptibility non-SRT anomalies in intermetallic compounds

    SciTech Connect

    Bartolome, J.; Garcia, L.M.; Lazaro, F.J.; Grincourt, Y.; Fuente, L.G. de la; Francisco, C. de; Munoz, J.M.; Fruchart, D.

    1994-03-01

    The anomaly detected in the magnetic a.c. susceptibility of many intermetallic compounds between 100 and 300 K, and in particular in Nd{sub 2}Fe{sub 14}B at 220 K, has been induced in a controlled manner by thermal annealing. The anomaly has been interpreted in terms of thermal activated processes of defects imposing their dynamical behavior on the domain walls coupled to them, thus solving the controversy on its origin.

  7. Implant-assisted magnetic drug targeting in permeable microvessels: Comparison of two-fluid statistical transport model with experiment

    NASA Astrophysics Data System (ADS)

    ChiBin, Zhang; XiaoHui, Lin; ZhaoMin, Wang; ChangBao, Wang

    2017-03-01

    In experiments and theoretical analyses, this study examines the capture efficiency (CE) of magnetic drug carrier particles (MDCPs) for implant-assisted magnetic drug targeting (IA-MDT) in microvessels. It also proposes a three-dimensional statistical transport model of MDCPs for IA-MDT in permeable microvessels, which describes blood flow by the two-fluid (Casson and Newtonian) model. The model accounts for the permeable effect of the microvessel wall and the coupling effect between the blood flow and tissue fluid flow. The MDCPs move randomly through the microvessel, and their transport state is described by the Boltzmann equation. The regulated changes and factors affecting the CE of the MDCPs in the assisted magnetic targeting were obtained by solving the theoretical model and by experimental testing. The CE was negatively correlated with the blood flow velocity, and positively correlated with the external magnetic field intensity and microvessel permeability. The predicted CEs of the MDCPs were consistent with the experimental results. Additionally, under the same external magnetic field, the predicted CE was 5-8% higher in the IA-MDT model than in the model ignoring the permeability effect of the microvessel wall.

  8. Magnetic Nanoparticle Thermometer: An Investigation of Minimum Error Transmission Path and AC Bias Error

    PubMed Central

    Du, Zhongzhou; Su, Rijian; Liu, Wenzhong; Huang, Zhixing

    2015-01-01

    The signal transmission module of a magnetic nanoparticle thermometer (MNPT) was established in this study to analyze the error sources introduced during the signal flow in the hardware system. The underlying error sources that significantly affected the precision of the MNPT were determined through mathematical modeling and simulation. A transfer module path with the minimum error in the hardware system was then proposed through the analysis of the variations of the system error caused by the significant error sources when the signal flew through the signal transmission module. In addition, a system parameter, named the signal-to-AC bias ratio (i.e., the ratio between the signal and AC bias), was identified as a direct determinant of the precision of the measured temperature. The temperature error was below 0.1 K when the signal-to-AC bias ratio was higher than 80 dB, and other system errors were not considered. The temperature error was below 0.1 K in the experiments with a commercial magnetic fluid (Sample SOR-10, Ocean Nanotechnology, Springdale, AR, USA) when the hardware system of the MNPT was designed with the aforementioned method. PMID:25875188

  9. Magnetic nanoparticle thermometer: an investigation of minimum error transmission path and AC bias error.

    PubMed

    Du, Zhongzhou; Su, Rijian; Liu, Wenzhong; Huang, Zhixing

    2015-04-14

    The signal transmission module of a magnetic nanoparticle thermometer (MNPT) was established in this study to analyze the error sources introduced during the signal flow in the hardware system. The underlying error sources that significantly affected the precision of the MNPT were determined through mathematical modeling and simulation. A transfer module path with the minimum error in the hardware system was then proposed through the analysis of the variations of the system error caused by the significant error sources when the signal flew through the signal transmission module. In addition, a system parameter, named the signal-to-AC bias ratio (i.e., the ratio between the signal and AC bias), was identified as a direct determinant of the precision of the measured temperature. The temperature error was below 0.1 K when the signal-to-AC bias ratio was higher than 80 dB, and other system errors were not considered. The temperature error was below 0.1 K in the experiments with a commercial magnetic fluid (Sample SOR-10, Ocean Nanotechnology, Springdale, AR, USA) when the hardware system of the MNPT was designed with the aforementioned method.

  10. High power density energy harvester with high permeability magnetic material embedded in a rotating wheel

    NASA Astrophysics Data System (ADS)

    Wang, Qi; Zhang, Yi; Sun, Nian X.; McDaniel, J. Gregory; Wang, Ming L.

    2012-04-01

    This work presents an alternative design of a rotating energy harvester, which possesses the capability of powering electronic sensors and wireless sensor networks within vehicle. This energy harvester design is based on magnetostatic coupling between a stationary circular-arc hard magnet array and rotating magnetic solenoids, which consists of a unique core with high permeability (μr>10,000) to significantly increase the output power density. A prototype of this rotating energy harvesting system has been fabricated and demonstrated on a rotating wheel at speeds from 10 to 60 miles/hour (mph). Test of the prototype equipped with energy storage circuit and wireless transmission board on actual vehicle has been carried out. Results of different rotating frequencies show average power densities from 1 to 5 W/cm3. A numerical and experimental study of powering a real-time wireless tire pressure monitoring system (TPMS) reveals that the energy harvester design generates constant and steady power sufficient for continuous operation of the TPMS.

  11. The effect of surface grain reversal on the AC losses of sintered Nd-Fe-B permanent magnets

    NASA Astrophysics Data System (ADS)

    Moore, Martina; Roth, Stefan; Gebert, Annett; Schultz, Ludwig; Gutfleisch, Oliver

    2015-02-01

    Sintered Nd-Fe-B magnets are exposed to AC magnetic fields in many applications, e.g. in permanent magnet electric motors. We have measured the AC losses of sintered Nd-Fe-B magnets in a closed circuit arrangement using AC fields with root mean square-values up to 80 mT (peak amplitude 113 mT) over the frequency range 50 to 1000 Hz. Two magnet grades with different dysprosium content were investigated. Around the remanence point the low grade material (1.7 wt% Dy) showed significant hysteresis losses; whereas the losses in the high grade material (8.9 wt% Dy) were dominated by classical eddy currents. Kerr microscopy images revealed that the hysteresis losses measured for the low grade magnet can be mainly ascribed to grains at the sample surface with multiple domains. This was further confirmed when the high grade material was subsequently exposed to DC and AC magnetic fields. Here a larger number of surface grains with multiple domains are also present once the step in the demagnetization curve attributed to the surface grain reversal is reached and a rise in the measured hysteresis losses is evident. If in the low grade material the operating point is slightly offset from the remanence point, such that zero field is not bypassed, its AC losses can also be fairly well described with classical eddy current theory.

  12. EMI obscuration of buried UXO by geophysical magnetic permeability, anthropogenic clutter, and by magnitude disparities

    NASA Astrophysics Data System (ADS)

    O'Neill, K.; Shubitidze, F.; Sun, K.; Shamatava, I.; Paulsen, K.

    2005-05-01

    For UWB (30 Hz - 100 kHz) electromagnetic induction (EMI) sensor discrimination of unexploded ordnance (UXO), we evaluate first the effects of significant magnetic permeability in the surrounding soil. Measured data and theoretical arguments suggest that ground effects can often be accounted for by using a simple halfspace analytical solution. Thus, when target responses are strong enough, free-space target signature shapes can still be used for discrimination if properly compensated. At the same time, even in artificially well-mixed, physically smoothed settings, local variations in soil permeability can be a significant source of signal clutter. Cases with multiple UXO"s beneath dispersed small metallic clutter are also considered as instances in which clutter may dominate. In simulations of two comparably sized UXO"s at comparable depths with a signal to clutter ratio (SCR) of ~ 20, UWB data distinguishes the two objects reliably over a ground surface measurement grid. For similar cases but with the objects at significantly different depths relative to one another, one cannot distinguish the deeper target, even with the same noise level and with UWB data. Measurements illustrate the level of EMI SCR to be expected from dispersed small metallic items collected from a firing range. For cases with a single piece of clutter and a much more massive UXO immediately below, simulations show almost complete obscuration of the UXO, in both frequency and time domains. This is not caused by signal blockage but results from different degrees of proximity to the sensor, i.e. from the consequent signal magnitude disparity.

  13. Magnetic sensing for microstructural assessment of power station steels: Differential permeability and magnetic hysteresis

    NASA Astrophysics Data System (ADS)

    Karimian, N.; Wilson, J. W.; Yin, W.; Liu, J.; Davis, C. L.; Peyton, A. J.

    2013-06-01

    Failure of power station steel components can have severe economic impacts and also present significant risks to life and the environment. Currently components are inspected during costly shut-downs as no in-situ technique exists to monitor changes in microstructure of in-service steel components. Electromagnetic inspection has the potential to provide information on microstructure changes in power station steels in-situ. In this paper, tests have been carried out on pipe and tube samples in different microstructural conditions, using a lab-based closed magnetic circuit and impedance measurement systems. EM properties have been identified with correlations to material properties, which can quantify degradation in-situ and at elevated temperatures.

  14. Ac magnetotransport in La 0.7Sr 0.3Mn 0.95Fe 0.05O 3 at low dc magnetic fields

    NASA Astrophysics Data System (ADS)

    Barik, S. K.; Mahendiran, R.

    2011-12-01

    We report the ac electrical response of La 0.7Sr 0.3Mn 1- xFe xO 3(x=0.05) as a function of temperature, magnetic field (H) and frequency of radio frequency ( rf) current ( f=0.1-20 MHz). The ac impedance (Z) was measured while rf current directly passes through the sample as well as in a coil surrounding the sample. It is found that with increasing frequency of the rf current, Z(T) shows an abrupt increase accompanied by a peak at the ferromagnetic Curie temperature. The peak decreases in magnitude and shifts down with increasing value of H. We find a magnetoimpedance of ΔZ/Z=-21% for ΔH=500 Oe at f=1 MHz around room temperature when the rf current flows directly through the sample and ΔZ/Z=-65.9% when the rf current flows through a coil surrounding the sample. It is suggested that the magnetoimpedance observed is a consequence of suppression of transverse permeability which enhances skin depth for current flow. Our results indicate that the magnetic field control of high frequency impedance of manganites is more useful than direct current magnetoresistance for low-field applications.

  15. Spin superconductivity and ac-Josephson effect in Graphene system under strong magnetic field

    NASA Astrophysics Data System (ADS)

    Liu, Haiwen; Jiang, Hua; Sun, Qing-Feng; Xie, X. C.; Collaborative Innovation Center of Quantum Matter, Beijing, China Collaboration

    We study the spin superconductivity in Graphene system under strong magnetic field. From the microscopically Gor'kov method combined with the Aharonov-Casher effect, we derive the effective Landau-Ginzburg free energy and analyze the time evolution of order parameter, which is confirmed to be the off-diagonal long range order. Meanwhile, we compare the ground state of spin superconductivity to the canted-antiferromagnetic state, and demonstrate the equivalence between these two states. Moreover, we give out the pseudo-field flux quantization condition of spin supercurrent, and propose an experimental measurable ac-Josephson effect of spin superconductivity in this system.

  16. Design of a novel phase-decoupling permanent magnet brushless ac motor

    NASA Astrophysics Data System (ADS)

    Cui, Wei; Chau, K. T.; Jiang, J. Z.; Fan, Ying

    2005-05-01

    This paper presents a phase-decoupling permanent magnet brushless ac motor which can offer better controllability, faster response, and smoother torque than its counterparts. The key is due to its different motor configuration and simple scalar control. The motor configuration is so unique that it inherently offers the features of phase decoupling, flux focusing, and flux shaping, hence achieving independent phase control, fast response, and smooth torque. The scalar control is fundamentally different from the complicated vector control. It can achieve direct torque control through independent control of the phase currents. The proposed motor is prototyped and experimentally verified.

  17. A low frequency MEMS energy harvester scavenging energy from magnetic field surrounding an AC current-carrying wire

    NASA Astrophysics Data System (ADS)

    Olszewski, Oskar Z.; Houlihan, Ruth; Mathewson, Alan; Jackson, Nathan

    2016-10-01

    This paper reports on a low frequency piezoelectric energy harvester that scavenges energy from a wire carrying an AC current. The harvester is described, fabricated and characterized. The device consists of a silicon cantilever with integrated piezoelectric capacitor and proof-mass that incorporates a permanent magnet. When brought close to an AC current carrying wire, the magnet couples to the AC magnetic field from a wire, causing the cantilever to vibrate and generate power. The measured average power dissipated across an optimal resistive load was 1.5 μW. This was obtained by exciting the device into mechanical resonance using the electro-magnetic field from the 2 A source current. The measurements also reveal that the device has a nonlinear response that is due to a spring hardening mechanism.

  18. Dynamic melting and impurity particle tracking in continuously adjustable AC magnetic field

    NASA Astrophysics Data System (ADS)

    Bojarevics, V.; Pericleous, K.

    2016-07-01

    The analysis of semi-levitation melting is extended to account for the presence of particles (impurities, broken metal dendrite agglomerates, bubbles) during the full melting cycle simulated numerically using the pseudo-spectral schemes. The AC coil is dynamically moving with the melt front progress, while the generated Joule heat serves to enhance the melting rate. The electromagnetic force is decomposed into the time average and the oscillating parts. The time average effects on the particle transport are investigated previously using approximations derived for a locally uniform magnetic field. This paper presents expressions for the skin-layer type of the AC force containing also the pulsating part which contributes to the particle drag by the ‘history’ and ‘added mass’ contributions. The intense turbulence in the bulk of molten metal additionally contributes to the particle dispersion. The paper attempts to demonstrate the importance of each of the mentioned effects onto the particle transport during the melting until the final pouring stage. The method could be extended to similar AC field controlled melting/solidification processes.

  19. δ-FeOOH: a superparamagnetic material for controlled heat release under AC magnetic field

    NASA Astrophysics Data System (ADS)

    Chagas, Poliane; da Silva, Adilson Cândido; Passamani, Edson Caetano; Ardisson, José Domingos; de Oliveira, Luiz Carlos Alves; Fabris, José Domingos; Paniago, Roberto M.; Monteiro, Douglas Santos; Pereira, Márcio César

    2013-04-01

    Experimental evidences on its in vitro use reveal that δ-FeOOH is a material that release-controlled amount of heat if placed under an AC magnetic field. δ-FeOOH nanoparticles were prepared by precipitating Fe(OH)2 in alkaline solution followed by fast oxidation with H2O2. XRD and 57Fe Mössbauer spectroscopy data confirmed that δ-FeOOH is indeed the only iron-bearing compound in the produced sample. TEM images evidence that the averaged particle sizes for this δ-FeOOH sample is 23 nm. Magnetization measurements indicate that these δ-FeOOH particles behave superparamagnetically at 300 K; its saturation magnetization was found to be 13.2 emu g-1; the coercivity and the remnant magnetization were zero at 300 K. The specific absorption rate values at 225 kHz were 2.1, 6.2, and 34.2 W g-1, under 38, 64, and 112 mT, respectively. The release rate of heat can be directly controlled by changing the mass of δ-FeOOH nanoparticles. In view of these findings, the so-prepared δ-FeOOH is a real alternative to be further tested as a material for medical practices in therapies involving magnetic hyperthermia as in clinical oncology.

  20. Coherence-population-trapping transients induced by an ac magnetic field

    NASA Astrophysics Data System (ADS)

    Margalit, L.; Rosenbluh, M.; Wilson-Gordon, A. D.

    2012-06-01

    Coherent-population-trapping transients induced by an ac magnetic field are investigated theoretically for a realistic three-level Λ system in the D1 line of 87Rb. The contributions to the transient probe absorption from the various subsystems that compose the realistic atomic system are examined and the absorption of each Λ subsystem is compared to that of a simple Λ system. The population redistribution due to optical pumping is shown to be the dominant cause of the difference between the contributions of the various subsystems to the oscillatory character of the probe absorption. We also discuss the series of transients that reappear every half-cycle time of a modulated magnetic field when the system is in two-photon resonance, and we study the transient behavior as a function of the probe detuning. The effect of a buffer gas on the amplitude and shape of the transients is considered.

  1. Analysis and reoperation of the magnetic permeability spectra of textured composite based on Z-type hexaferrite by using Cramers-Kronig relations

    NASA Astrophysics Data System (ADS)

    Dotsenko, O. A.; Suslyaev, V. I.; Frolov, K. O.; Zhuravlyova, E. V.

    2017-01-01

    The frequency dependences of the magnetic permeability of textured composite based on Ba3Co2,4Fe23,2O41 ferrite are given. The magnetic permeability spectra were obtained by coaxial method in the frequency range 0.01–18 GHz. The expert judgement on the spectra was made by using Cramers – Kronig relations. It was shown, that the Cramers – Kronig relations can be used to correct magnetic permeability measurements by reciprocal recalculation of the frequency dependences of the real and imaginary parts.

  2. AC susceptibility as a tool to probe the dipolar interaction in magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Landi, Gabriel T.; Arantes, Fabiana R.; Cornejo, Daniel R.; Bakuzis, Andris F.; Andreu, Irene; Natividad, Eva

    2017-01-01

    The dipolar interaction is known to substantially affect the properties of magnetic nanoparticles. This is particularly important when the particles are kept in a fluid suspension or packed within nano-carriers. In addition to its usual long-range nature, in these cases the dipolar interaction may also induce the formation of clusters of particles, thereby strongly modifying their magnetic anisotropies. In this paper we show how AC susceptibility may be used to obtain information regarding the influence of the dipolar interaction in a sample. We develop a model which includes both aspects of the dipolar interaction and may be fitted directly to the susceptibility data. The usual long-range nature of the interaction is implemented using a mean-field approximation, whereas the particle-particle aggregation is modeled using a distribution of anisotropy constants. The model is then applied to two samples studied at different concentrations. One consists of spherical magnetite nanoparticles dispersed in oil and the other of cubic magnetite nanoparticles embedded on polymeric nanospheres. We also introduce a simple technique to address the presence of the dipolar interaction in a given sample, based on the height of the AC susceptibility peaks for different driving frequencies.

  3. Creep Void Detection for Low Alloy Steel Using AC Magnetic Method

    SciTech Connect

    Shiwa, M.; Cheng, W.; Kume, R.

    2004-02-26

    Nondestructive detection of creep void was developed for low alloy steel by using AC magnetic method. Two types of 2.25Cr-1Mo steel specimens, base metal (BM) and simulated heat affected zone (HAZ) under aging and creep damage, were prepared for the tests. A differential type probe was used to detect AC magnetic signals. The exciting and detecting coils were coaxially arranged with a ferrite core. Signals were recorded using a 2-channel waveform recorder. The equivalent hysteresis loss (HL) was analyzed. It was observed that the HL of BM and HAZ changed in opposite direction, that is, HL of BM increased and HL of HAZ decreased with aging time. On the other hand, the HLs of both BM and HAZ decreased with creep time. The HL of creep samples was affected by both aging and stress-induced damage. In order to evaluate creep damage, stress-induced damage (SID) parameter was proposed to remove aging factor of materials from HL. Creep void were observed by scanning electron microscope (SEM) for all creep damage samples of SID value under 0.8.

  4. Magnetic AC susceptibility study of the cobalt segregation process in melt-spun Cu-Co alloys

    NASA Astrophysics Data System (ADS)

    López, A.; Lázaro, F. J.; von Helmolt, R.; García-Palacios, J. L.; Wecker, J.; Cerva, H.

    1998-08-01

    Temperature and frequency-dependent AC susceptibility has been used to characterize Cu 90Co 10 melt-spun ribbons, about 15 μm thick, in order to see to what extent this technique yields information about the segregation of cobalt in this alloy. The interpretation of the results includes, as a prerequisite, a transmission electron microscopy (TEM) characterization and makes use of previous field-dependent magnetization data on the same samples. Due to their different dynamical magnetic properties, the large intergrain precipitates, the small intragrain aggregates and the remaining Cu-Co solid solution, previously detected in these alloys, are independently observed by AC susceptibility as ferromagnetic, superparamagnetic and spin-glass species. Contrary to other, mostly local, microstructural characterization techniques of use with nanostructured materials, the AC susceptibility yields information about the whole sample. Furthermore, unlike the measurement of the temperature-dependent magnetization which is the magnetic technique mostly used until now, the results are basically independent of the thermal history. The correlation between microstructure and magnetic properties is illustrated by a scheme which includes magnetization, AC susceptibility and TEM data.

  5. Dynamic model tracking design for low inertia, high speed permanent magnet ac motors.

    PubMed

    Stewart, P; Kadirkamanathan, V

    2004-01-01

    Permanent magnet ac (PMAC) motors have existed in various configurations for many years. The advent of rare-earth magnets and their associated highly elevated levels of magnetic flux makes the permanent magnet motor attractive for many high performance applications from computer disk drives to all electric racing cars. The use of batteries as a prime storage element carries a cost penalty in terms of the unladen weight of the vehicle. Minimizing this cost function requires the minimum electric motor size and weight to be specified, while still retaining acceptable levels of output torque. This tradeoff can be achieved by applying a technique known as flux weakening which will be investigated in this paper. The technique allows the speed range of a PMAC motor to be greatly increased, giving a constant power range of more than 4:1. A dynamic model reference controller is presented which has advantages in ease of implementation, and is particularly suited to dynamic low inertia applications such as clutchless gear changing in high performance electric vehicles. The benefits of this approach are to maximize the torque speed envelope of the motor, particularly advantageous when considering low inertia operation. The controller is examined experimentally, confirming the predicted performance.

  6. Influence of AC external magnetic field on guidance force relaxation between HTS bulk and NdFeB guideway

    NASA Astrophysics Data System (ADS)

    Zhang, Longcai; Wang, Suyu; Wang, Jiasu; Zheng, Jun

    2007-12-01

    Superconducting maglev vehicle is one of the most promising applications of HTS bulks. In such a system, the HTS bulks are always exposed to time-varying external magnetic field, which is generated by the inhomogeneous surface magnetic field of the NdFeB guideway. So it is required to study whether the guidance force of the bulks is influenced by the inhomogeneity. In this paper, we studied the characteristics of the guidance force relaxation between the HTS bulk and the NdFeB guideway by an experiment in which AC external magnetic field generated by an electromagnet was used to simulate the time-varying external magnetic field caused by the inhomogeneity of the guideway. From the experiment results, it was found that the guidance force was decreased with the application of the AC external magnetic field, and the decay increased with the amplitude and was almost independent of the frequency.

  7. Improved estimates of formation factor for combined electrical and nuclear magnetic resonance models of permeability of sandstone cores

    NASA Astrophysics Data System (ADS)

    Osterman, G. K.; Keating, K.; Binley, A. M.; Slater, L. D.; McDonald, R.

    2014-12-01

    In spite of the importance of permeability in controlling numerous hydrogeological and biogeochemical processes, the property can be exceptionally difficult to measure directly in the field. Recently, nuclear magnetic resonance (NMR) has become an increasingly popular method, both in the lab and the field, for hydrogeophysical investigations due to its sensitivity to water content and pore surface area. Additionally, previous work has shown that the electrical formation factor can be used as a proxy for the tortuosity of the pore space—a parameter NMR is incapable of detecting—in permeability models. However, the formation factor is impossible to accurately measure in the field using DC electrical methods, as the measured conductivity cannot be decomposed into the fluid and surface conduction components. Therefore, our approach is to use induced polarization (IP) and spectral induced polarization (SIP) in the laboratory to correct for the influence of surface conductivity in the formation factor calculation. The corrected formation factor can then be used along with NMR parameters for more accurate permeability estimation. Laboratory SIP and NMR datasets were acquired on 40 sandstone cores with a range of permeabilities spanning six orders of magnitude as estimated from gas permeameter measurements. We examine how different estimates of the electrical formation factor can be combined with the NMR transverse relaxation time to estimate permeability. Specifically, we compare the electrical formation factor measured at high and low pore-fluid salinity with the formation factor derived using IP and SIP. Using both empirical and mechanistic petrophysical relationships, we explore the utility of IP- and SIP-corrected formation factors in tandem with NMR parameters for permeability prediction as compared to the low-salinity formation factor typically measured in the field. Furthermore, we develop our models using IP and SIP data that may be acquired in the field

  8. AC-magnetic susceptibility of Dy doped ZnO compounds

    NASA Astrophysics Data System (ADS)

    Akyol, Mustafa; Ekicibil, Ahmet; Kiymaç, Kerim

    2015-07-01

    Dy doped ZnO polycrystalline diluted magnetic semiconductor compounds have been prepared by the so called solid state reaction method. We have studied the M-H and AC magnetic properties of the compounds by using a PPMS magnetometer, and explored the phases and crystal structure by using a X-ray powder diffractometer. The XRD spectra of the compounds show that the substitution of Dy3+ for Zn2+ causes almost no change in the hexagonal wurtzite structure of ZnO, and the Dy3+ ions are successfully substituted into the Zn2+ site of the ZnO matrix. The magnetic measurements, M-H and χ-T, for T in the range from 10 to 300 K, show a paramagnetic behavior, including indirect antiferromagnetic couplings between some Dy3+ magnetic moments. Since the Curie-Weiss temperatures, θ, are all negative but decrease in magnitude with increasing Dy concentration. On the other hand, the calculated effective magnetic moments, μeff, per Dy3+ ion slowly increase with increasing Dy concentration, but are all very close to the free ion value of μeff, ~11.0 μB. Therefore, the trends of the magnitudes of θs and μeff s indicate that the samples are not only paramagnetic but also have antiferromagnetic couplings due to the complex nature of the compounds. In addition, the thermal variation of average magnetic moment, Peff(T), per Dy3+ ion have been calculated, and have been found to be gradually increasing with increasing temperature and Dy concentration.

  9. Laboratory characterization of hydraulic properties of sandstones using induced polarization and nuclear magnetic resonance for a joint permeability model

    NASA Astrophysics Data System (ADS)

    Osterman, G. K.; Keating, K.; Binley, A. M.; Slater, L. D.

    2015-12-01

    The permeability of sandstones can be modeled using the Katz and Thompson (KT) model which relates permeability to a characteristic hydraulic length scale, typically measured by mercury injection, and the electrically interconnected porosity. In situ estimation of these hydraulic parameters remains a challenge in hydrogeology; emerging geophysical technologies may help to solve this problem. Induced polarization (IP) and nuclear magnetic resonance (NMR) are two geophysical methods shown to be sensitive to physical properties of the pore space that control fluid flow, such as the pore size distribution. Using laboratory data collected on sandstone cores with a diverse range of properties, we demonstrate that our measured NMR parameters best predict the characteristic hydraulic length scale of the KT model, while the IP data can be used to improve estimates of the true formation factor. We incorporate these estimated hydraulic parameters into a KT model to derive an IP-NMR permeability model that compares favorably to permeability estimates from the KT model using mercury injection measurements. Furthermore, the resulting model uses parameters that are potentially measureable in the field; future work will focus on implementing the model at the field scale.

  10. Size dependent heating ability of CoFe2O4 nanoparticles in AC magnetic field for magnetic nanofluid hyperthermia

    NASA Astrophysics Data System (ADS)

    Çelik, Özer; Can, Musa Mutlu; Firat, Tezer

    2014-03-01

    We investigated the size dependent magnetic properties and heating mechanism of spinel CoFe2O4 nanoparticles, which synthesized using the nonhydrolytic thermal decomposition method. The size of CoFe2O4 nanoparticles was arranged with the variation of solvent type, reflux time, and reflux temperature. The optimum size range was determined for magnetic fluid hyperthermia. The particles with 9.9 ± 0.3 nm average diameter have the highest heating ability in the AC magnetic field having 3.2 kA/m amplitude and 571 kHz frequency. The maximum specific absorption rate of 22 W/g was obtained for 9.9 ± 0.3 nm sized CoFe2O4 nanoparticles. The calculations and experimental results showed the dominancy of Brownian relaxation at the heat production of synthesized 9.9 ± 0.3 nm nanoparticles. In contrary, the magneto-heating in 5.4 ± 0.2 nm particles mainly originated from Neel relaxation.

  11. Generation of liquid metal structures of high aspect ratio by application of an ac magnetic field

    NASA Astrophysics Data System (ADS)

    Andreev, Oleg; Pothérat, Alban; Thess, André

    2010-06-01

    We study how the shape of parts obtained through the LASER cladding process can be controlled by application of an ac magnetic field by means of two simple physical models: a numerical and an experimental one. More specifically, we show that straight metallic joints of high aspect ratio can be obtained by using inductors of triangular cross-section that concentrate electromagnetic forces at the bottom of the joint. The effect is first demonstrated on a numerical model for an infinitely long joint such as: we illustrate how the joint shape can be controlled by varying the inclination of the inductor and for a magnetic Bond number Bom=60 (which measures the ratio of electromagnetic to capillary forces), we obtain a joint of aspect ratio up to 7.2. We further find that inductor angles in the range 15°-25° lead to joint side faces that are close to vertical. These findings are then verified experimentally by placing a liquid metal drop in a purpose built inductor of triangular cross-section. We find a good agreement between the theoretical prediction of our two-dimensional model and the real three-dimensional drop. For the highest magnetic Bond number our generator could deliver, Bom=20.19, we achieved a drop aspect ratio of 2.73.

  12. ac magnetic trackers for biomedical application: now and in the near future

    NASA Astrophysics Data System (ADS)

    Murry, Herschell F.

    1996-04-01

    A number of ac magnetic trackers have been, and are now being, used in the medical community for varied applications from describing electronically the exact shape of a subject to tracking movement of objects. A good reason for using this technology is that the magnetic fields pass through the body without occlusions and without ionizing radiation. This paper commences with descriptions of several such tools readily available, including our 3D input stylus and 3DRAW tablet defining object dimensions to 0.01' accuracy and our close-in Short Ranger transmitter operating precisely between 2' - 12' over the subject. For the future, R&D and military electronics sponsored topics such as a metal distortion insensitive magnetic source, a high performance 240 Hz (or up to eight sensors each operating at 30 Hz) tracker with the processing power to virtually eliminate metal distortion effects and an approach for building a biologically insertible tracker are discussed to indicate the potential for new tracking tools. Discussion of needs from the medical community is encouraged in order to better guide efforts in applying our specialty technology to biomedical applications where ewe are neophytes.

  13. Magnetic and microwave absorbing properties of Co2+ substituted nickel-zinc ferrites with the emphasis on initial permeability studies

    NASA Astrophysics Data System (ADS)

    Ghodake, J. S.; Kambale, Rahul C.; Shinde, T. J.; Maskar, P. K.; Suryavanshi, S. S.

    2016-03-01

    Nanocrystalline Co2+ substituted Zn0.35Ni0.60-xCoxFe2.05O4 (Where x=0.0, 0.1, 0.2, 0.3 and 0.4) system have been synthesized by citrate-nitrate combustion route. X-ray diffraction study shows the formation of single phase cubic spinel structure without any impurity phases. Morphological observation shows agglomerated grains with different shapes and sizes which is the typical characteristics of magnetic nanoparticles prepared by combustion route. The saturation magnetization of cobalt substituted Ni-Zn ferrites is found to be higher than that of pure Ni-Zn ferrite. The coercivity and retentivity of cobalt substituted Ni-Zn ferrite increases with the increasing cobalt content. Initial permeability and loss factor have been studied as the function of composition and frequency. The real (μ‧) and imaginary (μ‧‧) part of initial permeability of cobalt substituted Ni-Zn ferrites decreases while its loss factor increases with the increasing cobalt content. In the lower frequency region the imaginary part of initial permeability (μ‧‧) of all samples is found to be decreasing rapidly with increasing frequency. The microwave absorption properties of cobalt substituted Ni-Zn ferrites were also investigated; all samples exhibit the absorption in the frequency range 2.3-2.5 GHz. Thus, the prepared materials can be used as a rubber composite microwave absorber and may be useful in RADAR application.

  14. Numerical simulations of electromagnetic behavior and AC loss in rectangular bulk superconductor with an elliptical flaw under AC magnetic fields

    NASA Astrophysics Data System (ADS)

    Xia, Jing; Zhou, Youhe

    2015-07-01

    This paper presents a finite element model based on the H-formulation to solve the electromagnetic behavior and AC loss in rectangular bulk superconductor with an elliptical flaw in AC external field condition. Both the interior flaw and the edge flaw are considered. A modified E-J power law which is valid for an arbitrary current density range is adopted in order to predict the strong local enhancement of the current density in the vicinity of the flaw tip. The results for the usual E-J power law are calculated for comparison as well. The simulation results show that the existence of the flaw significantly blocks the flow of the induced current and forces the current to redistribute around it. Meanwhile, the strong local enhancement of the current density is observed in the vicinity of the flaw tip. Furthermore, the influences of the size and position of the flaw on the local enhancement of the current density in the vicinity of the flaw tip are investigated. In addition, it is found that the influence of the flaw on the AC loss of the sample is slight for both cases of the interior flaw and the edge flaw.

  15. A laboratory study to estimate pore geometric parameters of sandstones using complex conductivity and nuclear magnetic resonance for permeability prediction

    NASA Astrophysics Data System (ADS)

    Osterman, Gordon; Keating, Kristina; Binley, Andrew; Slater, Lee

    2016-06-01

    We estimate parameters from the Katz and Thompson permeability model using laboratory complex electrical conductivity (CC) and nuclear magnetic resonance (NMR) data to build permeability models parameterized with geophysical measurements. We use the Katz and Thompson model based on the characteristic hydraulic length scale, determined from mercury injection capillary pressure estimates of pore throat size, and the intrinsic formation factor, determined from multisalinity conductivity measurements, for this purpose. Two new permeability models are tested, one based on CC data and another that incorporates CC and NMR data. From measurements made on forty-five sandstone cores collected from fifteen different formations, we evaluate how well the CC relaxation time and the NMR transverse relaxation times compare to the characteristic hydraulic length scale and how well the formation factor estimated from CC parameters compares to the intrinsic formation factor. We find: (1) the NMR transverse relaxation time models the characteristic hydraulic length scale more accurately than the CC relaxation time (R2 of 0.69 and 0.33 and normalized root mean square errors (NRMSE) of 0.16 and 0.21, respectively); (2) the CC estimated formation factor is well correlated with the intrinsic formation factor (NRMSE=0.23). We demonstrate that that permeability estimates from the joint-NMR-CC model (NRMSE=0.13) compare favorably to estimates from the Katz and Thompson model (NRMSE=0.074). This model advances the capability of the Katz and Thompson model by employing parameters measureable in the field giving it the potential to more accurately estimate permeability using geophysical measurements than are currently possible.

  16. Effects of AC/DC magnetic fields, frequency, and nanoparticle aspect ratio on cellular transfection of gene vectors

    NASA Astrophysics Data System (ADS)

    Ford, Kris; Mair, Lamar; Fisher, Mike; Rowshon Alam, Md.; Juliano, Rudolph; Superfine, Richard

    2008-10-01

    In order to make non-viral gene delivery a useful tool in the study and treatment of genetic disorders, it is imperative that these methodologies be further refined to yield optimal results. Transfection of magnetic nanoparticles and nanorods are used as non-viral gene vectors to transfect HeLa EGFP-654 cells that stably express a mutated enhanced green fluorescent protein (EGFP) gene. We deliver antisense oligonucleotides to these cells designed to correct the aberrant splicing caused by the mutation in the EGFP gene. We also transfect human bronchial endothelial cells and immortalized WI-38 lung cells with pEGFP-N1 vectors. To achieve this we bind the genes to magnetic nanoparticles and nanorods and introduce magnetic fields to effect transfection. We wish to examine the effects of magnetic fields on the transfection of these particles and the benefits of using alternating (AC) magnetic fields in improving transfection rates over direct (DC) magnetic fields. We specifically look at the frequency dependence of the AC field and particle aspect ratio as it pertains to influencing transfection rate. We posit that the increase in angular momentum brought about by the AC field and the high aspect ratio of the nanorod particles, is vital to generating the force needed to move the particle through the cell membrane.

  17. Angular dependence of direct current decay in a closed YBCO double-pancake coil under external AC magnetic field and reduction by magnetic shielding

    NASA Astrophysics Data System (ADS)

    Geng, J.; Zhang, H.; Li, C.; Zhang, X.; Shen, B.; Coombs, T. A.

    2017-03-01

    High T c superconducting (HTS) coils are ideal candidates in the use of high field magnets. HTS coils carrying a direct current, however, suffer a non-negligible loss when they are exposed to an external AC magnetic field. Although this phenomenon is well known, no study concerning AC magnetic field angular dependence of direct current decay has ever been shown. In this work, we experimentally investigate the direct current decay characteristics in a closed double pancake coil made of a YBCO coated conductor under external AC field. AC field of different angles with respect to the coil plane is applied. Results show that the current decay rate presents a strong angular dependence. The fastest decay occurs when the field is parallel to the coil plane, in which case the surface of the tape in the outermost layer experiences most flux variation. To reduce the decay rate, we propose wrapping superconducting tapes around the outermost layer of the coil to shield external AC field. This method significantly reduces direct current decay rate under parallel field, without affecting the perpendicular self-field of the coil.

  18. Sensor-less pseudo-sinusoidal drive for a permanent-magnet brushless ac motor

    NASA Astrophysics Data System (ADS)

    Liu, Li-Hsiang; Chern, Tzuen-Lih; Pan, Ping-Lung; Huang, Tsung-Mou; Tsay, Der-Min; Kuang, Jao-Hwa

    2012-04-01

    The precise rotor-position information is required for a permanent-magnet brushless ac motor (BLACM) drive. In the conventional sinusoidal drive method, either an encoder or a resolver is usually employed. For position sensor-less vector control schemes, the rotor flux estimation and torque components are obtained by complicated coordinate transformations. These computational intensive methods are susceptible to current distortions and parameter variations. To simplify the method complexity, this work presents a sensor-less pseudo-sinusoidal drive scheme with speed control for a three-phase BLACM. Based on the sinusoidal drive scheme, a floating period of each phase current is inserted for back electromotive force detection. The zero-crossing point is determined directly by the proposed scheme, and the rotor magnetic position and rotor speed can be estimated simultaneously. Several experiments for various active angle periods are undertaken. Furthermore, a current feedback control is included to minimize and compensate the torque fluctuation. The experimental results show that the proposed method has a competitive performance compared with the conventional drive manners for BLACM. The proposed scheme is straightforward, bringing the benefits of sensor-less drive and negating the need for coordinate transformations in the operating process.

  19. Detection of blood-nerve barrier permeability by magnetic resonance imaging.

    PubMed

    Wessig, Carsten

    2011-01-01

    The blood-nerve barrier (BNB) separates the endoneurium from the endovascular space and the epineurial connective tissue. An intact BNB is very important for integrity and functions of the nerve fibers within the endoneurial space. Disruption of the BNB which leads to functional and structural impairment of the peripheral nerve plays an important role in many disorders of the peripheral nerve like Wallerian degeneration, inflammatory nerve disorders, and demyelination. So far, this increased BNB permeability can only be assessed ex vivo. Assessing BNB disruption in vivo would be of great value for studying disorders of the peripheral nervous system. Gadofluorine M (Gf), a new amphiphilic contrast agent for MRI, accumulates in rat nerves with increased permeability of the BNB. After application of Gf, T1-weighted MR images show contrast enhancement of nerves with a disrupted BNB. This new tool of assessing BNB permeability in vivo is described.

  20. Comparison study of the magnetic permeability and dc conductivity of Co-Ni-Li ferrite nanoparticles and their bulk counterparts

    NASA Astrophysics Data System (ADS)

    Assar, S. T.; Abosheiasha, H. F.; El Nimr, M. K.

    2014-03-01

    The temperature dependence of relative permeability and dc electrical conductivity of nanosamples and their bulk counterparts of Co0.5Ni0.5-2xLixFe2+xO4 (from x=0.00 to 0.25 in step of 0.05) was investigated. The values of the relative permeability of the nano-samples are lower than their bulk counterparts as a result of porous and nano-grained structure besides the effect of the larger volume of grain boundaries in the nanosamples. Moreover, the dc conductivity of the nanosamples is higher than their bulk counterparts. This is probable explained according to the shorter metal-oxygen bonding length and higher lattice vibrations of the nanosamples. Also, the values of the relative permeability of both nano and bulk samples exhibit stability over a considerable range of temperatures. This may make them useful in practical applications that require stability. All the nanosamples show high rising Curie temperature values with increasing the Li content up to the sample of x=0.15 thereafter a decrease of the Curie temperature occurs while the inverse behavior was observed in their bulk counterparts. The interpretation of these findings is explained in the discussion. Moreover, in general doping Co-Ni ferrites with Li ions improves their electrical and magnetic properties and this is clearly observed in the nanosample of x=0.15 which can be regarded as the most promising sample for microwave applications.

  1. Quantitative permeability magnetic resonance imaging in acute ischemic stroke: how long do we need to scan?

    PubMed

    Vidarsson, Logi; Thornhill, Rebecca E; Liu, Fang; Mikulis, David J; Kassner, Andrea

    2009-11-01

    Blood-brain barrier (BBB) permeability estimation with dynamic contrast-enhanced MRI (DCE-MRI) has shown significant potential for predicting hemorrhagic transformation (HT) in patients presenting with acute ischemic stroke (AIS). In this work, the effects of scan duration on quantitative BBB permeability estimates (KPS) were investigated. Data from eight patients (three with HT) aged 37-93 years old were retrospectively studied by directly calculating the standard deviation of KPS as a function of scan time. The uncertainty in KPS was reduced only slightly for a scan time of 3 min and 30 s (4% reduction in P value from .047 to .045). When more than 3 min and 30 s of data were used, quantitative permeability MRI was able to separate those patients who proceeded to HT from those who did not (P value <.05). Our findings indicate that reducing permeability acquisition times is feasible in keeping with the need to maintain time-efficient MR protocols in the setting of AIS.

  2. Analyze and experiment on AC magnetic field's effect to fiber optic gyroscopes in compact stabilization control systems

    NASA Astrophysics Data System (ADS)

    Zhang, Chao; Mao, Yao; Tian, Jing; Li, Zhijun

    2015-10-01

    Fiber optic gyroscopes (FOG) are getting more and more attention in areas such as stabilization control systems as they are all solid state and have a wide bandwidth. In stabilization systems that require wide bandwidth control, motors are usually used as actuating mechanism for active disturbance restrain. Voice coil motors (VCMs) are usually used in compact stabilization systems that require large torque and fast response. However, AC magnetic field, which can affect the output of FOG due to Faraday effect, will be generated during operation of VCMs. The frequency range affected by the AC magnetic field to the FOG's output is the same as VCMs drive signal frequency range, which is also exactly the stabilization system's working range. Therefore the effect of the AC magnetic field to FOGs must be evaluated to verify the feasibility of a stable system design that uses both FOGs and VCMs. In this article, the basic structure and operating principle of stabilization system is introduced. The influence of AC magnetic field to FOG is theoretically analyzed. The magnetic field generated by VCMs is numerically simulated based on the theory deduction of the magnetic field near energized wires. To verify the influence of the VCM generated magnetic field to the FOGs in practical designs, a simplified random fiber coil model is built for it's hard to accurately test the exact polarize axis's twisting rate in a fiber coil. The influence to the FOG's output of different random coil model is simulated and the result shows a same trend that the influence of the VCM's magnetic field to the FOG is reduced as the distance between the VCM and the FOG increasing. The influence of a VCM to a FOG with the same parameters is experimentally tested. In the Fourier transformed FOG data the same frequency point as the VCM drive signal frequency can be read. The result fit simulated result that as the distance increases, the influence decreases. The amplitude of the frequency point is just

  3. Evaluation of effective electric permittivity and magnetic permeability in metamaterial slabs by terahertz time-domain spectroscopy.

    PubMed

    Minowa, Yosuke; Fujii, Takashi; Nagai, Masaya; Ochiai, Tetsuyuki; Sakoda, Kazuaki; Hirao, Kazuyuki; Tanaka, Koichiro

    2008-03-31

    We established a novel method to evaluate effective optical constants by terahertz (THz) time domain spectroscopy and suggested a strict definition of optical constants and an expression for electromagnetic energy loss following the second law of thermodynamics. We deduced the effective optical constants of phosphor bronze wire grids in the THz region experimentally and theoretically. The results depend strongly on the polarization of the THz waves. When the electric field is parallel to the wires, we observed Drude-like electric permittivities with a plasma frequency reduced by a factor of 10(-3), whereas when the field is perpendicular, the sample behaved as a simple dielectric film. We also observed unexpected magnetic permeabilities, which originate from the non-resonant real magnetic response of finite size-conductors.

  4. A short-circuited coplanar waveguide to measure the permeability of magnetic thin films: Comparison with short-circuited microstrip line.

    PubMed

    Wei, Jinwu; Feng, Hongmei; Zhu, Zengtai; Liu, Qingfang; Wang, Jianbo

    2015-11-01

    A short-circuited coplanar waveguide jig was proposed due to its simple structure and potential applications, which was successfully used to measure the permeability spectra of magnetic thin film. The result obtained from the coplanar waveguide (CPW) jig exhibits typical ferromagnetic resonance spectra, which can be well fitted by a trade-off equation because the measured permeability spectra have a bit of asymmetry because of the special intensity distribution of the microwave magnetic field in the CPW. In order to confirm the availability of the shorted CPW jig, a previous short-circuited microstrip line jig was used to measure the permeability spectra of the same sample. The dynamic permeability results obtained by using different jigs are commendably consistent, and the accurate and valid results are also confirmed by using the vector network analyzer ferromagnetic resonance method.

  5. Study of the Dependence on Magnetic Field and Bias Voltage of an AC-Biased TES Microcalorimeter

    NASA Technical Reports Server (NTRS)

    Bandler, Simon

    2011-01-01

    At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in the AC bias configuration. For x-ray photons at 6keV the AC biased pixel shows a best energy resolution of 3.7eV, which is about a factor of 2 worse than the energy resolution observed in identical DC-biased pixels. To better understand the reasons of this discrepancy, we investigated the detector performance as a function of temperature, bias working point and applied magnetic field. A strong periodic dependence of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recent weak-link behaviour observed inTES microcalorimeters.

  6. Development of integrated AC-DC magnetometer using high-Tc SQUID for magnetic properties evaluation of magnetic nanoparticles in solution

    NASA Astrophysics Data System (ADS)

    Mawardi Saari, Mohd; Takagi, Ryuki; Kusaka, Toki; Ishihara, Yuichi; Tsukamoto, Yuya; Sakai, Kenji; Kiwa, Toshihiko; Tsukada, Keiji

    2014-05-01

    We developed an integrated AC-DC magnetometer using a high critical temperature superconducting quantum interference device (high-Tc SQUID) to evaluate the static and dynamic magnetic properties of magnetic nanoparticles (MNPs) in solution. The flux-transformer method consisted of first-order planar and axial differential coils that were constructed for static and dynamic magnetization measurements, respectively. Vibrating-sample and harmonic detection techniques were used to reduce interference from excitation magnetic fields in the static and dynamic magnetization measurements, respectively. Static and dynamic magnetization measurements were performed on commercially available iron oxide nanoparticles in diluted solutions. The magnetic responses increased with the increase in concentration of the solutions in both measurement results. The magnetization curves showed that the diamagnetic signal due to the carrier liquid of the iron oxide nanoparticles existed in a dilute solution. Biasing with a proper DC magnetic field in the dynamic magnetization measurement resulted in improved signals of the second and third harmonics. Therefore, highly sensitive magnetic characterizations of MNPs utilizing the static and dynamic magnetization measurement are possible via the developed system.

  7. Polymer-Based Materials of Controlled Permeability and Application of Photoinduced Magnetism

    DTIC Science & Technology

    2010-07-31

    electromagnetic properties of multilayer structures and composites, where one or more components are organic-based magnets.” For Years 1 and 2 of this... multilayer organic-based structures that operate as spintronic devices. It is anticipated that future work will further extend these materials and...organic-based magnetic semiconductor, V(TCNE)x (x ~ 2;Tc ~ 400 K), and its function as a spin injector/detector in hybrid magnetic multilayer devices

  8. Calorimetric AC loss measurement of MgB2 superconducting tape in an alternating transport current and direct magnetic field

    NASA Astrophysics Data System (ADS)

    See, K. W.; Xu, X.; Horvat, J.; Cook, C. D.; Dou, S. X.

    2012-11-01

    Applications of MgB2 superconductors in electrical engineering have been widely reported, and various studies have been made to define their alternating current (AC) losses. However, studies on the transport losses with an applied transverse DC magnetic field have not been conducted, even though this is one of the favored conditions in applications of practical MgB2 tapes. Methods and techniques used to characterize and measure these losses have so far been grouped into ‘electrical’ and ‘calorimetric’ approaches with external conditions set to resemble the application conditions. In this paper, we present a new approach to mounting the sample and employ the calorimetric method to accurately determine the losses in the concurrent application of AC transport current and DC magnetic fields that are likely to be experienced in practical devices such as generators and motors. This technique provides great simplification compared to the pickup coil and lock-in amplifier methods and is applied to a long length (˜10 cm) superconducting tape. The AC loss data at 20 and 30 K will be presented in an applied transport current of 50 Hz under external DC magnetic fields. The results are found to be higher than the theoretical predictions because of the metallic fraction of the tape that contributes quite significantly to the total losses. The data, however, will allow minimization of losses in practical MgB2 coils and will be used in the verification of numerical coil models.

  9. High-permeability functionalized silicone magnetic microspheres with low autofluorescence for biomedical applications.

    PubMed

    Evans, Benjamin A; Ronecker, Julia C; Han, David T; Glass, Daniel R; Train, Tonya L; Deatsch, Alison E

    2016-05-01

    Functionalized magnetic microspheres are widely used for cell separations, isolation of proteins and other biomolecules, in vitro diagnostics, tissue engineering, and microscale force spectroscopy. We present here the synthesis and characterization of a silicone magnetic microsphere which can be produced in diameters ranging from 0.5 to 50 μm via emulsion polymerization of a silicone ferrofluid precursor. This bottom-up approach to synthesis ensures a uniform magnetic concentration across all sizes, leading to significant advances in magnetic force generation. We demonstrate that in a size range of 5-20 μm, these spheres supply a full order of magnitude greater magnetic force than leading commercial products. In addition, the unique silicone matrix exhibits autofluorescence two orders of magnitude lower than polystyrene microspheres. Finally, we demonstrate the ability to chemically functionalize our silicone microspheres using a standard EDC reaction, and show that our folate-functionalized silicone microspheres specifically bind to targeted HeLa and Jurkat cells. These spheres show tremendous potential for replacing magnetic polystyrene spheres in applications which require either large magnetic forces or minimal autofluorescence, since they represent order-of-magnitude improvements in each. In addition, the unique silicone matrix and proven biocompatibility suggest that they may be useful for encapsulation and targeted delivery of lipophilic pharmaceuticals.

  10. Magnetic nanobeads present during enzymatic amplification and labeling for a simplified DNA detection protocol based on AC susceptometry

    NASA Astrophysics Data System (ADS)

    Bejhed, Rebecca S.; Strømme, Maria; Svedlindh, Peter; Ahlford, Annika; Strömberg, Mattias

    2015-12-01

    Magnetic biosensors are promising candidates for low-cost point-of-care biodiagnostic devices. For optimal efficiency it is crucial to minimize the time and complexity of the assay protocol including target recognition, amplification, labeling and read-out. In this work, possibilities for protocol simplifications for a DNA biodetection principle relying on hybridization of magnetic nanobeads to rolling circle amplification (RCA) products are investigated. The target DNA is recognized through a padlock ligation assay resulting in DNA circles serving as templates for the RCA process. It is found that beads can be present during amplification without noticeably interfering with the enzyme used for RCA (phi29 polymerase). As a result, the bead-coil hybridization can be performed immediately after amplification in a one-step manner at elevated temperature within a few minutes prior to read-out in an AC susceptometer setup, i.e. a combined protocol approach. Moreover, by recording the phase angle ξ = arctan(χ″/χ'), where χ and χ″ are the in-phase and out-of-phase components of the AC susceptibility, respectively, at one single frequency the total assay time for the optimized combined protocol would be no more than 1.5 hours, often a relevant time frame for diagnosis of cancer and infectious disease. Also, applying the phase angle method normalization of AC susceptibility data is not needed. These findings are useful for the development of point-of-care biodiagnostic devices relying on bead-coil binding and magnetic AC susceptometry.

  11. The Blood Flow of Prandtl Fluid Through a Tapered Stenosed Arteries in Permeable Walls with Magnetic Field

    NASA Astrophysics Data System (ADS)

    Ellahi, R.; Rahman, S. U.; Nadeem, S.; Vafai, K.

    2015-03-01

    This Communication deals with the blood flow of Prandtl fluid through a tapered stenosed arteries having permeable walls. The governing equations of two-dimensional Prandtl fluid model are modelled in cylindrical coordinates. The highly nonlinear equations are simplified with the help of non-dimensional variables under the assumption of mild stenosis. The solution of reduced nonlinear equation subject to boundary condition of porous walls having the effects of Darcy's number and slip parameter are computed analytically with the help of perturbation method. Effects of emerging parameters such as impedance λ, slip parameter α, stenosis height δ, magnetic parameter and stress component Srz on velocity are illustrated graphically. The streamlines have also been presented to discuss the trapping bolus discipline.

  12. The ac-magnetic susceptibility and dielectric response of complex spin ordering processes in Mn₃O₄

    SciTech Connect

    Thota, Subhash E-mail: wilfrid.prellier@ensicaen.fr; Singh, Kiran; Simon, Ch.; Prellier, Wilfrid E-mail: wilfrid.prellier@ensicaen.fr; Nayak, Sanjib; Kumar, Jitendra

    2014-09-14

    We report a meticulous study of the ac-magnetization dynamics (χ{sub ac}(T)), relative dielectric permittivity ε{sub r}(T), and magneto-dielectric (Δε{sub r}/ε{sub r}(H)) response of various complex magnetic transitions that occur below the ferrimagnetic Néel temperature T{sub N} of Mn₃O₄. Besides the known sequence of transitions at T{sub N}~42.75 K, T₁~39 K, and T₂~34 K, the existence of a new anomaly reported recently at 38 K (T*) has been successfully probed by χ{sub ac}(T) and ε{sub r}(T) measurements. The effect of external dc-bias fields (H{sub DC}) and driving frequency (f) on the above mentioned transitions has been investigated in consonance with the ε{sub r}(T) and Δε{sub r}/ε{sub r}(T,H) results. For the first time, we observed a clear hysteresis of about 5.15 K in the zero-field ε{sub r}(T) across the incommensurate-to-commensurate transition T₂~34 K, which provides evidence to the first-order nature of this transition. The Arrott plot (H/M vs. M²}) criterion has been used to distinguish the nature of all the sequential transitions that take place below T{sub N}.

  13. Magnetization Response of the Bulk and Supplementary Magnetic Domain Structure in High-Permeability Steel Laminations Visualized In Situ by Neutron Dark-Field Imaging

    NASA Astrophysics Data System (ADS)

    Betz, B.; Rauscher, P.; Harti, R. P.; Schäfer, R.; Irastorza-Landa, A.; Van Swygenhoven, H.; Kaestner, A.; Hovind, J.; Pomjakushina, E.; Lehmann, E.; Grünzweig, C.

    2016-08-01

    Industrial transformer cores are composed of stacked high-permeability steel laminations (HPSLs). The performance and degree of efficiency of transformers are directly determined by the magnetic properties of each HPSL. In this article, we show how the neutron dark-field image (DFI) allows for the in situ visualization of the locally resolved response of the bulk and supplementary magnetic domain structures in HPSLs under the influence of externally applied magnetic fields. In particular, we investigate the domain formation and growth along the initial magnetization curve up to the saturated state. For decreasing field, we visualize the recurrence of the hysteretic domain structure down to the remanent state. Additionally, the DFI allows us to derive a correlation between the grain orientation and the corresponding volume and supplementary domain structure. Furthermore, we visualize the influence of the insulation coating, introducing desired tensile stresses on the domain structures. To compare our DFI findings to traditional methods, we perform complementary surface-sensitive magneto-optical Kerr-microscopy investigations.

  14. Superconducting-magnetic heterostructures: a method of decreasing AC losses and improving critical current density in multifilamentary conductors.

    PubMed

    Glowacki, B A; Majoros, M

    2009-06-24

    Magnetic materials can help to improve the performance of practical superconductors on the macroscale/microscale as magnetic diverters and also on the nanoscale as effective pinning centres. It has been established by numerical modelling that magnetic shielding of the filaments reduces AC losses in self-field conditions due to decoupling of the filaments and, at the same time, it increases the critical current of the composite. This effect is especially beneficial for coated conductors, in which the anisotropic properties of the superconductor are amplified by the conductor architecture. However, ferromagnetic coatings are often chemically incompatible with YBa(2)Cu(3)O(7) and (Pb,Bi)(2)Sr(2)Ca(2)Cu(3)O(9) conductors, and buffer layers have to be used. In contrast, in MgB(2) conductors an iron matrix may remain in direct contact with the superconducting core. The application of superconducting-magnetic heterostructures requires consideration of the thermal and electromagnetic stability of the superconducting materials used. On one hand, magnetic materials reduce the critical current gradient across the individual filaments but, on the other hand, they often reduce the thermal conductivity between the superconducting core and the cryogen, which may cause destruction of the conductor in the event of thermal instability. A possible nanoscale method of improving the critical current density of superconducting conductors is the introduction of sub-micron magnetic pinning centres. However, the volumetric density and chemical compatibility of magnetic inclusions has to be controlled to avoid suppression of the superconducting properties.

  15. Tilted Magnetic Levitation Enables Measurement of the Complete Range of Densities of Materials with Low Magnetic Permeability.

    PubMed

    Nemiroski, Alex; Soh, Siowling; Kwok, Sen Wai; Yu, Hai-Dong; Whitesides, George M

    2016-02-03

    Magnetic levitation (MagLev) of diamagnetic or weakly paramagnetic materials suspended in a paramagnetic solution in a magnetic field gradient provides a simple method to measure the density of small samples of solids or liquids. One major limitation of this method, thus far, has been an inability to measure or manipulate materials outside of a narrow range of densities (0.8 g/cm(3) < ρ < 2.3 g/cm(3)) that are close in density to the suspending, aqueous medium. This paper explores a simple method-"tilted MagLev"-to increase the range of densities that can be levitated magnetically. Tilting the MagLev device relative to the gravitational vector enables the magnetic force to be decreased (relative to the magnetic force) along the axis of measurement. This approach enables many practical measurements over the entire range of densities observed in matter at ambient conditions-from air bubbles (ρ ≈ 0) to osmium and iridium (ρ ≈ 23 g/cm(3)). The ability to levitate, simultaneously, objects with a broad range of different densities provides an operationally simple method that may find application to forensic science (e.g., for identifying the composition of miscellaneous objects or powders), industrial manufacturing (e.g., for quality control of parts), or resource-limited settings (e.g., for identifying and separating small particles of metals and alloys).

  16. Study of the Dependency on Magnetic Field and Bias Voltage of an AC-Biased TES Microcalorimeter

    NASA Technical Reports Server (NTRS)

    Gottardi, L.; Bruijn, M.; denHartog, R.; Hoevers, H.; deKorte, P.; vanderKuur, J.; Linderman, M.; Adams, J.; Bailey, C.; Bandler, S.; Chervenak, J.; Eckart, M.; Finkbeiner, F.; Kelley, R.; Kilbourne, C.; Porter, F.; Sadlier, J.; Smith, S.

    2012-01-01

    At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in an AC bias configuration. For x-ray photons at 6 keV the pixel shows an x-ray energy resolution Delta E(sub FWHM) = 3.7 eV, which is about a factor 2 worse than the energy resolution observed in an identical DC-biased pixel. In order to better understand the reasons for this discrepancy we characterized the detector as a function of temperature, bias working point and applied perpendicular magnetic field. A strong periodic dependency of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recently observed weak-link behaviour of a TES microcalorimeter.

  17. Magnetic ageing study of high and medium permeability nanocrystalline FeSiCuNbB alloys

    NASA Astrophysics Data System (ADS)

    Lekdim, Atef; Morel, Laurent; Raulet, Marie-Ange

    2017-04-01

    increasing the energy efficiency is one of the most important issues in modern power electronic systems. In aircraft applications, the energy efficiency must be associated with a maximum reduction of mass and volume, so a high components compactness. A consequence from this compactness is the increase of operating temperature. Thus, the magnetic materials used in these applications, have to work at high temperature. It raises the question of the thermal ageing problem. The reliability of these components operating at this condition becomes a real problem which deserves serious interest. Our work takes part in this context by studying the magnetic material thermal ageing. The nanocrystalline materials are getting more and more used in power electronic applications. Main advantages of nanocrystalline materials compared to ferrite are: high saturation flux density of almost 1.25 T and low dynamic losses for low and medium frequencies. The nanocrystalline Fe73.5Cu1Nb3Si15.5B7 alloys have been chosen in our aging study. This study is based on monitoring the magnetic characteristics for several continuous thermal ageing (100, 150, 200 and 240 °C). An important experimental work of magnetic characterization is being done following a specific monitoring protocol. Elsewhere, X-Ray Diffraction and magnetostriction measurements were carried out to support the study of the anisotropy energies evolution with ageing. This latter is discussed in this paper to explain and give hypothesis about the ageing phenomena.

  18. EFFECT OF ANNEALING TEMPERATURE ON THE STRUCTURE AND AC MAGNETIC PROPERTIES OF Fe73Cu1Nb3.5-xVxSi13.5B9 (x = 1.0, 1.5, 2.0) NANOCRYSTALLINE SOFT MAGNETIC ALLOYS

    NASA Astrophysics Data System (ADS)

    Lu, Wei; Huang, Ping; Wang, Yuxin; Yan, Biao

    2013-07-01

    In this paper, Nb element was partially replaced by V element in Finemet-type Fe73Cu1Nb3.5-xVxSi13.5B9 (x = 1, 1.5, 2) alloys and the effect of annealing temperatures on the microstructure and AC magnetic properties of the samples are studied. The annealing temperatures affect the grain sizes of the bcc α-Fe phase greatly. When the annealing temperature is between 540-560°C, the samples have better AC magnetic properties than the samples annealed at other temperatures. The optimized annealing temperature of the studied samples is around 560°C. The coercivity and iron loss of the V2 sample is a little bit higher than that of V1 and V1.5 alloys while the amplitude permeability of V2 alloy is larger than that of V1 and V1.5, which indicate that the content of V element has strong influence on the magnetic properties of nanocrystalline soft magnetic alloys.

  19. AC magnetic field-assisted method to develop porous carbon nanotube/conducting polymer composites for application in thermoelectric materials

    NASA Astrophysics Data System (ADS)

    Chuang, Chun-Yu; Yang, Shu-Chian; Chang, Su-Hua; Yang, Ta-I.

    2015-04-01

    Thermoelectric materials are very effective in converting waste heat sources into useful electricity. Researchers are continuing to develop new polymeric thermoelectric materials. The segregated-network carbon nanotube (CNT)- polymer composites are most promising. Thus, the goal of this study is to develop novel porous CNT -polymer composites with improved thermoelectric properties. The research efforts focused on modifying the surface of the CNT with magnetic nanoparticles so that heat was released when subjecting to an AC magnetic field. Subsequently, polymers covered on the surface of the CNT were crosslinked. The porous CNT -polymer composites can be obtained by removing the un-crosslinked polymers. Polydimethylsiloxane polymer was utilized to investigate the effect of porosity and electrical conductivity on the thermoelectric properties of the composites. This AC magnetic field-assisted method to develop porous carbon nanotube/polymer composites for application in thermoelectric materials is introduced for the first time. The advantage of this method is that the electrical conductivity of the composites was high since we can easily to manipulate the CNT to form a conducting path. Another advantage is that the high porosity significantly reduced the thermal conductivity of the composites. These two advantages enable us to realize the polymer composites for thermoelectric applications. We are confident that this research will open a new avenue for developing polymer thermoelectric materials.

  20. Superconductor-Mediated Modification of Gravity? AC Motor Experiments with Bulk YBCO Disks in Rotating Magnetic Fields

    NASA Technical Reports Server (NTRS)

    Noever, David A.; Koczor, Ronald J.; Roberson, Rick

    1998-01-01

    We have previously reported results using a high precision gravimeter to probe local gravity changes in the neighborhood of large bulk-processed high-temperature superconductors. Podkietnov, et al (Podkietnov, E. and Nieminen, R. (1992) A Possibility of Gravitational Force Shielding by Bulk YBa2 Cu3 O7-x Superconductor, Physica C, C203:441-444.) have indicated that rotating AC fields play an essential role in their observed distortion of combined gravity and barometric pressure readings. We report experiments on large (15 cm diameter) bulk YBCO ceramic superconductors placed in the core of a three-phase, AC motor stator. The applied rotating field produces up to a 12,000 revolutions per minute magnetic field. The field intensity decays rapidly from the maximum at the outer diameter of the superconducting disk (less than 60 Gauss) to the center (less than 10 Gauss). This configuration was applied with and without a permanent DC magnetic field levitating the superconducting disk, with corresponding gravity readings indicating an apparent increase in observed gravity of less than 1 x 10(exp -6)/sq cm, measured above the superconductor. No effect of the rotating magnetic field or thermal environment on the gravimeter readings or on rotating the superconducting disk was noted within the high precision of the observation. Implications for propulsion initiatives and power storage flywheel technologies for high temperature superconductors will be discussed for various spacecraft and satellite applications.

  1. Pore fabric geometry inferred from magnetic and acoustic anisotropies in rocks with various mineralogy, permeability and porosity

    NASA Astrophysics Data System (ADS)

    Robion, Philippe; David, Christian; Dautriat, Jérémie; Colombier, Jean-Christian; Zinsmeister, Louis; Collin, Pierre-Yves

    2014-08-01

    The ferrofluid impregnation technique combined with anisotropy of magnetic susceptibility measurements (AMSff) is one of the ways to analyze the 3-D geometry of the pore space in a rock and indirectly to infer the anisotropy of permeability. We applied this method on different types of rocks (sandstones and carbonates) with a range of different porosity values (10-30%) and permeability (1 mD to 1 D). To get additional information on both the pore aspect ratio and the directional anisotropy we used another technique, measuring the anisotropy of P-waves velocity (APV) in dry and water saturated conditions. Comparing between both methods shows that despite the good agreement in directional data, inferring the true shape of the porosity is not straightforward. Modeling the presence of an elastic anisotropy in the solid matrix for sandstones allows one to get more consistent values for the pore aspect ratio obtained from both APV and AMSff. However for the carbonate rocks, due to an intricate distribution of microstructures, the aspect ratios obtained show significant discrepancies between the two methods. The ferrofluid method is very sensitive to the quality of the impregnation and suffers from a major drawback which is the threshold size of investigation, limited by the size of the magnetite nanoparticles (10 nm) and probably this method doesn't see all the porosity. On the other hand with acoustic methods, the range of porosity investigated is probably larger but several microstructural attributes can contribute to the elastic anisotropy which makes the pore shape effect more difficult to decipher. Therefore, we promote the combined use of both methods in order to get more reliable information on the pore shape in porous media.

  2. Microwave and millimeter wave dielectric permittivity and magnetic permeability of epsilon-gallium-iron-oxide nano-powders

    SciTech Connect

    Chao, Liu Afsar, Mohammed N.; Ohkoshi, Shin-ichi

    2015-05-07

    In millimeter wave frequency range, hexagonal ferrites with high uniaxial anisotropic magnetic fields are used as absorbers. These ferrites include M-type barium ferrite (BaFe{sub 12}O{sub 19}) and strontium ferrite (SrFe{sub 12}O{sub 19}), which have natural ferromagnetic resonant frequency range from 40 GHz to 60 GHz. However, the higher frequency range lacks suitable materials that support the higher frequency ferromagnetic resonance. A series of gallium-substituted ε-iron oxides (ε-Ga{sub x}Fe{sub 2−x}O{sub 3}) are synthesized, which have ferromagnetic resonant frequencies appearing over the frequency range of 30 GHz to 150 GHz. The ε-Ga{sub x}Fe{sub 2−x}O{sub 3} is synthesized by the sol-gel method. The particle sizes are observed to be smaller than 100 nm. In this paper, in-waveguide transmission and reflection method and the free space magneto-optical approach have been employed to study these newly developed ε-Ga{sub x}Fe{sub 2−x}O{sub 3} particles in millimeter waves. These techniques enable to obtain precise transmission spectra to determine the dielectric and magnetic properties of both isotropic and anisotropic ferrites in the microwave and millimeter wave frequency range from single set of direct measurements. The complex dielectric permittivity and magnetic permeability spectra of ε-Ga{sub x}Fe{sub 2−x}O{sub 3} are shown in this paper. Strong ferromagnetic resonances at different frequencies determined by the x parameter are found.

  3. Automatized and desktop AC-susceptometer for the in situ and real time monitoring of magnetic nanoparticles' synthesis by coprecipitation

    NASA Astrophysics Data System (ADS)

    Fernández-García, M. P.; Teixeira, J. M.; Machado, P.; Oliveira, M. R. F. F.; Maia, J. M.; Pereira, C.; Pereira, A. M.; Freire, C.; Araujo, J. P.

    2015-04-01

    The main purpose of this work was to design, develop, and construct a simple desktop AC susceptometer to monitor in situ and in real time the coprecipitation synthesis of magnetic nanoparticles. The design incorporates one pair of identical pick-up sensing coils and one pair of Helmholtz coils. The picked up signal is detected by a lock-in SR850 amplifier that measures the in- and out-of-phase signals. The apparatus also includes a stirrer with 45°-angle blades to promote the fast homogenization of the reaction mixture. Our susceptometer has been successfully used to monitor the coprecipitation reaction for the synthesis of iron oxide nanoparticles.

  4. AC driven magnetic domain quantification with 5 nm resolution

    PubMed Central

    Li, Zhenghua; Li, Xiang; Dong, Dapeng; Liu, Dongping; Saito, H.; Ishio, S.

    2014-01-01

    As the magnetic storage density increases in commercial products, e.g. the hard disc drives, a full understanding of dynamic magnetism in nanometer resolution underpins the development of next-generation products. Magnetic force microscopy (MFM) is well suited to exploring ferromagnetic domain structures. However, atomic resolution cannot be achieved because data acquisition involves the sensing of long-range magnetostatic forces between tip and sample. Moreover, the dynamic magnetism cannot be characterized because MFM is only sensitive to the static magnetic fields. Here, we develop a side-band magnetic force microscopy (MFM) to locally observe the alternating magnetic fields in nanometer length scales at an operating distance of 1 nm. Variations in alternating magnetic fields and their relating time-variable magnetic domain reversals have been demonstrated by the side-band MFM. The magnetic domain wall motions, relating to the periodical rotation of sample magnetization, are quantified via micromagnetics. Based on the side-band MFM, the magnetic moment can be determined locally in a volume as small as 5 nanometers. The present technique can be applied to investigate the microscopic magnetic domain structures in a variety of magnetic materials, and allows a wide range of future applications, for example, in data storage and biomedicine. PMID:25011670

  5. Study of AC magnetic heating characteristics of Co0.5Zn0.5Fe2O4 nanoparticles for magnetic hyperthermia therapy

    NASA Astrophysics Data System (ADS)

    Nikam, D. S.; Jadhav, S. V.; Khot, V. M.; Phadatare, M. R.; Pawar, S. H.

    2014-01-01

    Structural, magnetic properties and an alternating current (AC) magnetic heating characteristics of Co0.5Zn0.5Fe2O4 nanoparticles (CZF NPs) have been investigated with respect to the possible application for magnetic hyperthermia treatments. The Specific Absorption Rate (SAR) was measured in alternating magnetic fields of 167.5-335.2 Oe at fixed frequency of 265 kHz. CZF NPs were fabricated by the chemical co-precipitation method using sodium hydroxide (NaOH) as the precipitating agent. The morphology of the particles was analysed by Transmission Electron microscopy (TEM). The TEM reveals that the grains are nearly spherical in shape with average particles size of 19 nm. X-ray diffraction pattern indicated the sole existence of cubic spinel phase of CZF NPs. The magnetization (Ms) of CZF NPs was measured at room temperature (300 K) using a Vibrating Sample Magnetometer (VSM). The magnetic heating ability of NPs was studied with an induction heating system. A highest SAR value of 114.98 W/g for 5 mg/mL sample concentration (265 kHz, 335.2 Oe) was determined.

  6. Tools and Setups for Experiments with AC and Rotating Magnetic Fields

    ERIC Educational Resources Information Center

    Ponikvar, D.

    2010-01-01

    A rotating magnetic field is the basis for the transformation of electrical energy to mechanical energy. School experiments on the rotating magnetic field are rare since they require the use of specially prepared mechanical setups and/or relatively large, three-phase power supplies to achieve strong magnetic fields. This paper proposes several…

  7. High-frequency magnetic permeability of single- and multilayered (Co41Fe39B20) x (SiO2)100- x nanocomposites

    NASA Astrophysics Data System (ADS)

    Tarasova, O. S.; Sitnikov, A. V.; Kalinin, Yu. E.; Starostenko, S. N.; Granovskii, A. B.

    2016-12-01

    Thin film single-layered (Co41Fe39B20) x (SiO2)100- x nanocomposites at x = 30-80 at % and multilayered nanocomposites composed of 176 pairs of [(Co41Fe39B20)60(SiO2)40]/[(Co41Fe39B20)60(SiO2)40 + O2] have been prepared via ion-beam sputtering of the complex target. The concentration dependences of the magnetic permeability of single-layered films at a frequency of 50 MHz are characterized by maximum losses near x = 60 at %, whereas the percolation threshold with respect to the electric conductivity is x = 50 at %. The high-frequency magnetic permeability of films has been measured by the resonator method in the frequency range of 0.1—10 GHz. As is shown, while the single-layer film passes to the multilayered structure, the ferromagnetic resonance frequency shifts from 1.5 to 2.5 GHz, and the imaginary part of the magnetic permeability attains 200 that is presumably due to the inhibition of the perpendicular magnetic anisotropy component.

  8. Investigation of ac-magnetic field stimulated nanoelectroporation of magneto-electric nano-drug-carrier inside CNS cells

    PubMed Central

    Kaushik, Ajeet; Nikkhah-Moshaie, Roozbeh; Sinha, Raju; Bhardwaj, Vinay; Atluri, Venkata; Jayant, Rahul Dev; Yndart, Adriana; Kateb, Babak; Pala, Nezih; Nair, Madhavan

    2017-01-01

    In this research, we demonstrate cell uptake of magneto-electric nanoparticles (MENPs) through nanoelectroporation (NEP) using alternating current (ac)-magnetic field stimulation. Uptake of MENPs was confirmed using focused-ion-beam assisted transmission electron microscopy (FIB-TEM) and validated by a numerical simulation model. The NEP was performed in microglial (MG) brain cells, which are highly sensitive for neuro-viral infection and were selected as target for nano-neuro-therapeutics. When the ac-magnetic field optimized (60 Oe at 1 kHz), MENPs were taken up by MG cells without affecting cell health (viability > 92%). FIB-TEM analysis of porated MG cells confirmed the non-agglomerated distribution of MENPs inside the cell and no loss of their elemental and crystalline characteristics. The presented NEP method can be adopted as a part of future nanotherapeutics and nanoneurosurgery strategies where a high uptake of a nanomedicine is required for effective and timely treatment of brain diseases. PMID:28374799

  9. Increasing the high-frequency magnetic permeability of MnZn ferrite in polyaniline composites by incorporating silver

    NASA Astrophysics Data System (ADS)

    Babayan, V.; Kazantseva, N. E.; Sapurina, I.; Moučka, R.; Stejskal, J.; Sáha, P.

    2013-05-01

    A hybrid composite containing 73 vol% of MnZn ferrite, 21 vol% of polyaniline, and 6 vol% of silver is obtained by oxidative polymerization of aniline with silver nitrate in the presence of ferrite powder. The hybrid composite contains ferrite particles with a size of 40-80 μm coated by an inhomogeneous layer of polyaniline in the conducting emeraldine form. Silver in the form of nano- and submicrometre -size particles is localized both on the surface of ferrite particles and in the bulk of polyaniline coating. The electrical and magnetic properties of the hybrid composite are investigated and compared with the properties of a composite with 71 vol% of MnZn ferrite coated by a conducting polyaniline layer (29 vol%). The hybrid composite containing silver exhibits an increase in the real and imaginary parts of the complex permeability in the radio-frequency band by more than one and a half times compared with those of the MnZn ferrite-polyaniline composite. The high-frequency permittivity of both composites is determined by the properties of core-shell structure: electric properties of shell as well as its composition and uniformity.

  10. Boosted Hyperthermia Therapy by Combined AC Magnetic and Photothermal Exposures in Ag/Fe3O4 Nanoflowers.

    PubMed

    Das, R; Rinaldi-Montes, N; Alonso, J; Amghouz, Z; Garaio, E; García, J A; Gorria, P; Blanco, J A; Phan, M H; Srikanth, H

    2016-09-28

    Over the past two decades, magnetic hyperthermia and photothermal therapy are becoming very promising supplementary techniques to well-established cancer treatments such as radiotherapy and chemotherapy. These techniques have dramatically improved their ability to perform controlled treatments, relying on the procedure of delivering nanoscale objects into targeted tumor tissues, which can release therapeutic killing doses of heat either upon AC magnetic field exposure or laser irradiation. Although an intense research effort has been made in recent years to study, separately, magnetic hyperthermia using iron oxide nanoparticles and photothermal therapy based on gold or silver plasmonic nanostructures, the full potential of combining both techniques has not yet been systematically explored. Here we present a proof-of-principle experiment showing that designing multifunctional silver/magnetite (Ag/Fe3O4) nanoflowers acting as dual hyperthermia agents is an efficient route for enhancing their heating ability or specific absorption rate (SAR). Interestingly, the SAR of the nanoflowers is increased by at least 1 order of magnitude under the application of both an external magnetic field of 200 Oe and simultaneous laser irradiation. Furthermore, our results show that the synergistic exploitation of the magnetic and photothermal properties of the nanoflowers reduces the magnetic field and laser intensities that would be required in the case that both external stimuli were applied separately. This constitutes a key step toward optimizing the hyperthermia therapy through a combined multifunctional magnetic and photothermal treatment and improving our understanding of the therapeutic process to specific applications that will entail coordinated efforts in physics, engineering, biology, and medicine.

  11. Vortex flux dynamics and harmonic ac magnetic response of Ba(Fe0.94Ni0.06)2As2 bulk superconductor

    DOE PAGES

    Nikolo, Martin; Zapf, Vivien S.; Singleton, John; ...

    2016-07-22

    Vortex dynamics and nonlinear ac response are studied in a Ba(Fe0.94Ni0.06)2As2(Tc= 18.5 K) bulk superconductor in magnetic fields up to 12 T via ac susceptibility measurements of the first ten harmonics. A comprehensive study of the ac magnetic susceptibility and its first ten harmonics finds shifts to higher temperatures with increasing ac measurement frequencies (10 to 10,000 Hz) for a wide range of ac (1, 5, and 10 Oe) and dc fields (0 to 12 T). The characteristic measurement time constant t1 is extracted from the exponential fit of the data and linked to vortex relaxation. The Anderson-Kim Arrhenius lawmore » is applied to determine flux activation energy Ea/k as a function dc magnetic field. The de-pinning, or irreversibility lines, were determined by a variety of methods and extensively mapped. The ac response shows surprisingly weak higher harmonic components, suggesting weak nonlinear behavior. Lastly, our data does not support the Fisher model; we do not see an abrupt vortex glass to vortex liquid transition and the resistivity does not drop to zero, although it appears to approach zero exponentially.« less

  12. Magnetic resonance imaging of blood-brain barrier permeability in ischemic stroke using diffusion-weighted arterial spin labeling in rats.

    PubMed

    Tiwari, Yash V; Lu, Jianfei; Shen, Qiang; Cerqueira, Bianca; Duong, Timothy Q

    2016-01-01

    Diffusion-weighted arterial spin labeling magnetic resonance imaging has recently been proposed to quantify the rate of water exchange (Kw) across the blood-brain barrier in humans. This study aimed to evaluate the blood-brain barrier disruption in transient (60 min) ischemic stroke using Kw magnetic resonance imaging with cross-validation by dynamic contrast-enhanced magnetic resonance imaging and Evans blue histology in the same rats. The major findings were: (i) at 90 min after stroke (30 min after reperfusion), group Kw magnetic resonance imaging data showed no significant blood-brain barrier permeability changes, although a few animals showed slightly abnormal Kw. Dynamic contrast-enhanced magnetic resonance imaging confirmed this finding in the same animals. (ii) At two days after stroke, Kw magnetic resonance imaging revealed significant blood-brain barrier disruption. Regions with abnormal Kw showed substantial overlap with regions of hyperintense T2 (vasogenic edema) and hyperperfusion. Dynamic contrast-enhanced magnetic resonance imaging and Evans blue histology confirmed these findings in the same animals. The Kw values in the normal contralesional hemisphere and the ipsilesional ischemic core two days after stroke were: 363 ± 17 and 261 ± 18 min(-1), respectively (P < 0.05, n = 9). Kw magnetic resonance imaging is sensitive to blood-brain barrier permeability changes in stroke, consistent with dynamic contrast-enhanced magnetic resonance imaging and Evans blue extravasation. Kw magnetic resonance imaging offers advantages over existing techniques because contrast agent is not needed and repeated measurements can be made for longitudinal monitoring or averaging.

  13. Effective method to measure back emfs and their harmonics of permanent magnet ac motors

    NASA Astrophysics Data System (ADS)

    Jiang, Q.; Bi, C.; Lin, S.

    2006-04-01

    As the HDD spindle motors become smaller and smaller, the back electromotive forces (emfs) measurement faces the new challenges due to their low inertias and small sizes. This article proposes a novel method to measure the back emfs and their harmonic components of PM ac motors only through a freewheeling procedure. To eliminate the influence of the freewheeling deceleration, the phase flux linkages are employed to obtain the back emf amplitudes and phases of the fundamental and harmonic components by using finite Fourier series analysis. The proposed method makes the freewheeling measurement of the back emfs and their harmonics accurate and fast. It is especially useful for the low inertia PM ac motors, such as spindle motors for small form factor HDDs.

  14. Magnetic Properties of Feni Nanowire Arrays Assembled on Porous AAO Template by AC Electrodeposition

    NASA Astrophysics Data System (ADS)

    Wang, Pangpang; Gao, Lumei; Wang, Liqun; Zhang, Dongyan; Yang, Sen; Song, Xiaoping; Qiu, Zhiyong; Murakami, Ri-Ichi

    FeNi nanowire arrays were fabricated into the pores of porous alumina template by a simple alternating current electrodeposition method in this work. FeNi nanowires with different diameters were obtained depending on the pore size arrangement of alumina templates. FeNi nanowire arrays exhibited obviously magnetic anisotropy, and the easy axis was along the nanowires. When the applied magnetic field was parallel to the nanowires, the coercivity (Hc) and the maximum remnant ratio (Mr/Ms) are considerable higher than those while the magnetic field perpendicular to the nanowires. FeNi nanowires prepared in this work are expected to be utilized as the perpendicular magnetic recording media. The magnetic domain structure and the magnetizing mechanism of FeNi nanowires were also been discussed.

  15. Cell volume increase in murine MC3T3-E1 pre-osteoblasts attaching onto biocompatible tantalum observed by magnetic AC mode atomic force microscopy.

    PubMed

    Andersen, L Klembt; Contera, S Antoranz; Justesen, J; Duch, M; Hansen, O; Chevallier, J; Foss, M; Pedersen, F S; Besenbacher, F

    2005-12-02

    Magnetic AC mode (MACmode) atomic force microscopy (AFM) was used to study murine (mouse) MC3T3-E1 preosteoblastic cells attached to biocompatible tantalum substrates. Cell volumes of attached cells derived from AFM images were compared to volumes of detached cells in suspension measured by the Coulter sizing technique. An increase of approximately 50% in cell volume was observed when the cells attached to planar tantalum substrates and developed a flattened structure including lamellipodia. We address thoroughly the issues general to the AFM determination of absolute cell volumes, and compare our magnetic AC mode AFM measurements to hitherto reported cell volume determinations by contact mode AFM.

  16. Currents, magnetization and AC-losses of YBa 2Cu 3O 7 superconductors in rapidly changing magnetic fields

    NASA Astrophysics Data System (ADS)

    Kwasnitza, K.; Plotzner, V.; Waldmann, M.; Widmer, E.

    1988-06-01

    In YBa 2Cu 3O 7 samples of different shape time dependent magnetization currents were induced at 4.2K by the application of rapid magnetic field changes. This contactless method allows the study of the intergrain and intragrain currents in the resistive flux flow state.

  17. Hysteresis losses in MgB2 superconductors exposed to combinations of low AC and high DC magnetic fields and transport currents

    NASA Astrophysics Data System (ADS)

    Magnusson, N.; Abrahamsen, A. B.; Liu, D.; Runde, M.; Polinder, H.

    2014-11-01

    MgB2 superconductors are considered for generator field coils for direct drive wind turbine generators. In such coils, the losses generated by AC magnetic fields may generate excessive local heating and add to the thermal load, which must be removed by the cooling system. These losses must be evaluated in the design of the generator to ensure a sufficient overall efficiency. A major loss component is the hysteresis losses in the superconductor itself. In the high DC - low AC current and magnetic field region experimental results still lack for MgB2 conductors. In this article we reason towards a simplified theoretical treatment of the hysteresis losses based on available models in the literature with the aim of setting the basis for estimation of the allowable magnetic fields and current ripples in superconducting generator coils intended for large wind turbine direct drive generators. The resulting equations use the DC in-field critical current, the geometry of the superconductor and the magnitude of the AC magnetic field component as parameters. This simplified approach can be valuable in the design of MgB2 DC coils in the 1-4 T range with low AC magnetic field and current ripples.

  18. Investigation of surfactant-enhanced mass removal and flux reduction in 3D correlated permeability fields using magnetic resonance imaging.

    PubMed

    Zhang, Changyong; Werth, Charles J; Webb, Andrew G

    2008-09-10

    Magnetic resonance imaging (MRI) was used to visualize the NAPL source zone architecture before and after surfactant-enhanced NAPL dissolution in three-dimensional (3D) heterogeneously packed flowcells characterized by different longitudinal correlation lengths: 2.1 cm (aquifer 1) and 1.1 cm (aquifer 2). Surfactant flowpaths were determined by imaging the breakthrough of a paramagnetic tracer (MnCl(2)) analyzed by the method of moments. In both experimental aquifers, preferential flow occurred in high permeability materials with low NAPL saturations, and NAPL was preferentially removed from the top of the aquifers with low saturation. Alternate flushing with water and two surfactant pulses (5-6 pore volumes each) resulted in approximately 63% of NAPL mass removal from both aquifers. However, overall reduction in mass flux (Mass Flux 1) exiting the flowcell was lower in aquifer 2 (68%) than in aquifer 1 (81%), and local effluent concentrations were found to increase by as high as 120 times at local sampling ports from aquifer 2 after surfactant flushing. 3D MRI images of NAPL revealed that NAPL migrated downward and created additional NAPL source zones in previously uncontaminated areas at the bottom of the aquifers. The additional NAPL source zones were created in the direction transverse to flow in aquifer 2, which explains the higher mass flux relative to aquifer 1. Analysis using a total trapping number indicates that mobilization of NAPL trapped in the two coarsest sand fractions is possible when saturation is below 0.5 and 0.4, respectively. Results from this study highlight the potential impacts of porous media heterogeneity and NAPL source zone architecture on advanced in-situ flushing technologies.

  19. Review of russian literature on biological action of DC and low-frequency AC magnetic fields.

    PubMed

    Zhadin, M N

    2001-01-01

    This review considers the Russian scientific literature on the influence of weak static and of low-frequency alternating magnetic fields on biological systems. The review covers the most interesting works and the main lines of investigation during the period 1900 to the present. Shown here are the historical roots, beginning with the ideas of V. Vernadsky and A. Chizhevsky, which led in the field of Russian biology to an increasing interest in magnetic fields, based on an intimate connection between solar activity and life on the Earth, and which determined the peculiar development of Russian magnetobiology. The variety of studies on the effects of magnetic storms and extremely low-frequency, periodic variations of the geomagnetic field on human beings and animals as well as on social phenomena are described. The diverse experiments involving artificial laboratory magnetic fields acting on different biological entities under different conditions are also considered. A series of theoretical advances are reviewed that have paved the way for a step-by-step understanding of the mechanisms of magnetic field effects on biological systems. The predominantly unfavorable influence of magnetic fields on living beings is shown, but the cases of favorable influence of magnetic fields on human beings and lower animals are demonstrated as well. The majority of Russian investigations in this area of science has been unknown among the non-Russian speaking audience for many reasons, primarily because of a language barrier. Therefore, it is hoped that this review may be of interest to the international scientific community.

  20. Mathematical Analysis of Hall Effect on Transient Hartman Flow about a Rotating Horizontal Permeable Surface in a Porous Medium under Inclined Magnetic Field.

    PubMed

    Suresh, M; Manglik, A

    2014-01-01

    This paper proposes the exact solution for unsteady flow of a viscous incompressible electrically conducting fluid past a impulsively started infinite horizontal surface which is rotating with an angular velocity embedded in a saturated porous medium under the influence of strong magnetic field with hall effect. Our study focuses on the change of direction of the external magnetic field on the flow system which leads to change in the flow behavior and skin frictional forces at the boundary. Systems of flow equations are solved using Laplace transform technique. The impacts of control parameters Hartman number, rotation of the system, hall effect, inclination of the magnetic field, and Darcy number on primary and secondary velocities are shown graphically, skin friction at horizontal boundary in tabular form. For validating our results, in the absence of permeability of the porous medium and inclination of the magnetic field the results are in good agreement with the published results.

  1. Mathematical Analysis of Hall Effect on Transient Hartman Flow about a Rotating Horizontal Permeable Surface in a Porous Medium under Inclined Magnetic Field

    PubMed Central

    Suresh, M.; Manglik, A.

    2014-01-01

    This paper proposes the exact solution for unsteady flow of a viscous incompressible electrically conducting fluid past a impulsively started infinite horizontal surface which is rotating with an angular velocity embedded in a saturated porous medium under the influence of strong magnetic field with hall effect. Our study focuses on the change of direction of the external magnetic field on the flow system which leads to change in the flow behavior and skin frictional forces at the boundary. Systems of flow equations are solved using Laplace transform technique. The impacts of control parameters Hartman number, rotation of the system, hall effect, inclination of the magnetic field, and Darcy number on primary and secondary velocities are shown graphically, skin friction at horizontal boundary in tabular form. For validating our results, in the absence of permeability of the porous medium and inclination of the magnetic field the results are in good agreement with the published results. PMID:27433540

  2. Tools and setups for experiments with AC and rotating magnetic fields

    NASA Astrophysics Data System (ADS)

    Ponikvar, D.

    2010-09-01

    A rotating magnetic field is the basis for the transformation of electrical energy to mechanical energy. School experiments on the rotating magnetic field are rare since they require the use of specially prepared mechanical setups and/or relatively large, three-phase power supplies to achieve strong magnetic fields. This paper proposes several experiments and describes setups and tools which are easy to obtain and work with. Free software is offered to generate the required signals by a personal computer. The experiments can be implemented in introductory physics courses on electromagnetism for undergraduates or specialized courses at high schools.

  3. Layer-by-layer self-assembly of micro-capsules for the magnetic activation of semi-permeable nano-shells

    NASA Astrophysics Data System (ADS)

    Prouty, Malcolm D.

    2007-12-01

    Layer-by-layer (LbL) self-assembly has demonstrated broad perspectives for encapsulating, and the controllable delivery, of drugs. The nano-scale polymer layers have the capability of material protection. Magnetic nanoparticles have great potential to be applied with LbL technology to achieve both "focusing" of the encapsulated drugs to a specific location followed by "switching" them on to release the encapsulated drugs. In this work, Phor21-betaCG(ala), dextran, and dexamethasone were used as model drugs. Encapsulation of these drugs with layer-by-layer self-assembly formed biolnano robotic capsules for controlled delivery and drug release. Silica nanoparticles coated with polyelectrolyte layers of sodium carboxymethyl cellulose (CMC) or gelatin B, along with an oppositely charged peptide drug (Phor2l-betaCG(ala)), were prepared using LbL self-assembly and confirmed using QCM and zeta potential measurements. The peptide drug was assembled as a component of the multilayer walls. The release kinetics of the embedded peptide were determined. Up to 18% of the embedded Phor21-betaCG(ala) was released from the CMC multilayers over a period of 28 hours. The release was based on physiological conditions, and an external control mechanism using magnetic nanoparticles needed to be developed. Magnetic permeability control experiments were setup by applying LbL self-assembly on MnCO3 micro-cores to fabricate polyelectrolyte microcapsules embedded with superparamagnetic gold coated cobalt (Co Au) nanoparticles. An alternating magnetic field was applied to the microcapsules to check for changes in permeability. Permeability experiments were achieved by adding fluorescein isothiocyanate (FITC) labeled dextran to the microcapsule solution. Before an alternating magnetic field was applied, the capsules remained impermeable to the FITC-dextran; however, after an alternating magnetic field was applied for 30 minutes, approximately 99% of the capsules were filled with FITC

  4. A cluster-glass magnetic state in R5Pd2 (R = Ho, Tb) compounds evidenced by AC-susceptibility and neutron scattering measurements

    NASA Astrophysics Data System (ADS)

    Gubkin, A. F.; Sherstobitova, E. A.; Terentyev, P. B.; Hoser, A.; Baranov, N. V.

    2013-06-01

    AC- and DC-susceptibility, high-field magnetization and neutron diffraction measurements have been performed in order to study the magnetic state of R5Pd2 (R = Ho, Tb) compounds. The results show that both compounds undergo cluster-glass freezing upon cooling below Tf. According to the neutron diffraction a long-range magnetic order is absent down to 2 K and magnetic clusters with short-range incommensurate antiferromagnetic correlations exist not only below Tf but also in a wide temperature range above the freezing temperature (at least up to 2Tf). A complex cluster-glass magnetic state existing in Ho5Pd2 and Tb5Pd2 down to low temperatures results in rather complicated magnetization behavior in DC and AC magnetic fields. Such an unusual magnetic state in compounds with a high rare-earth concentration may be associated with the layered type of their crystal structure and with substantial atomic disorder, which results in frustrations in the magnetic subsystem.

  5. Real-time liver uptake and biodistribution of magnetic nanoparticles determined by AC biosusceptometry.

    PubMed

    Quini, Caio C; Próspero, André G; Calabresi, Marcos F F; Moretto, Gustavo M; Zufelato, Nicholas; Krishnan, Sunil; Pina, Diana R; Oliveira, Ricardo B; Baffa, Oswaldo; Bakuzis, Andris F; Miranda, Jose R A

    2017-02-16

    We describe the development of a joint in vivo/ex vivo protocol to monitor magnetic nanoparticles in animal models. Alternating current biosusceptometry (ACB) enables the assessment of magnetic nanoparticle accumulation, followed by quantitative analysis of concentrations in organs of interest. We present a study of real-time liver accumulation, followed by the assessment of sequential biodistribution using the same technique. For quantification, we validated our results by comparing all of the data with electron spin resonance (ESR). The ACB had viable temporal resolution and accuracy to differentiate temporal parameters of liver accumulation, caused by vasculature extravasation and macrophages action. The biodistribution experiment showed different uptake profiles for different doses and injection protocols. Comparisons with the ESR system indicated a correlation index of 0.993. We present the ACB system as an accessible and versatile tool to monitor magnetic nanoparticles, allowing in vivo and real-time evaluations of distribution and quantitative assessments of particle concentrations.

  6. Magnetic-resonance imaging and simplified Kozeny-Carman-model analysis of glass-bead packs as a frame of reference to study permeability of reservoir rocks

    NASA Astrophysics Data System (ADS)

    Wang, Dayong; Han, Dongyan; Li, Wenqiang; Zheng, Zhanpeng; Song, Yongchen

    2017-03-01

    Permeability variation in reservoir rocks results from the combined effects of various factors, and makes porosity-permeability (ϕ-k) relationships more complex, or, in some cases, non-existent. In this work, the ϕ-k relationship of macroscopically homogeneous glass-bead packs is deduced based on magnetic resonance imaging (MRI) measurement and Kozeny-Carman (K-C) model analysis; these are used as a frame of reference to study permeability of reservoir rocks. The results indicate: (1) most of the commonly used simplified K-C models (e.g. the simplified traditional (omitting specific surface area), high-order, threshold, and fractal models) are suitable for estimating permeability of glass-bead packs. The simplified traditional model does not present obvious dependence on rock samples. Whether for the glass-bead packs or clean natural sandstones, the sample coefficients almost remain invariant. Comparably, the high-order, the fractal, and the threshold models are strongly sample-specific and cannot be extrapolated from the glass-bead packs to natural sandstones; (2) the ϕ-k relationships of quartz sands and silty sandstones resemble those of the glass-bead packs, but they significantly deviate from the K-C models at low porosities due to small pore entry radius; (3) a small amount of intergranular cements (<10%v) does not affect the general variation trend of permeability with porosity but can potentially increase predictive errors of the K-C models, whereas in the case of more cements, the ϕ-k relationships of sandstones become uncertain and cannot be described by any of these K-C models.

  7. Applied AC and DC magnetic fields cause alterations in the mitotic cycle of early sea urchin embryos

    SciTech Connect

    Levin, M.; Ernst, S.G.

    1995-09-01

    This study demonstrates that exposure to 60 Hz magnetic fields (3.4--8.8 mt) and magnetic fields over the range DC-600 kHz (2.5--6.5 mT) can alter the early embryonic development of sea urchin embryos by inducing alterations in the timing of the cell cycle. Batches of fertilized eggs were exposed to the fields produced by a coil system. Samples of the continuous cultures were taken and scored for cell division. The times of both the first and second cell divisions were advanced by ELF AC fields and by static fields. The magnitude of the 60 Hz effect appears proportional to the field strength over the range tested. the relationship to field frequency was nonlinear and complex. For certain frequencies above the ELF range, the exposure resulted in a delay of the onset of mitosis. The advance of mitosis was also dependent on the duration of exposure and on the timing of exposure relative to fertilization.

  8. Crustal permeability

    USGS Publications Warehouse

    Gleeson, Tom; Ingebritsen, Steven E.

    2016-01-01

    Permeability is the primary control on fluid flow in the Earth’s crust and is key to a surprisingly wide range of geological processes, because it controls the advection of heat and solutes and the generation of anomalous pore pressures.  The practical importance of permeability – and the potential for large, dynamic changes in permeability – is highlighted by ongoing issues associated with hydraulic fracturing for hydrocarbon production (“fracking”), enhanced geothermal systems, and geologic carbon sequestration.  Although there are thousands of research papers on crustal permeability, this is the first book-length treatment.  This book bridges the historical dichotomy between the hydrogeologic perspective of permeability as a static material property and the perspective of other Earth scientists who have long recognized permeability as a dynamic parameter that changes in response to tectonism, fluid production, and geochemical reactions. 

  9. Simulation of fluid flow induced by opposing ac magnetic fields in a continuous casting mold

    SciTech Connect

    Chang, F.C.; Hull, J.R.; Beitelman, L.

    1995-07-01

    A numerical simulation was performed for a novel electromagnetic stirring system employing two rotating magnetic fields. The system controls stirring flow in the meniscus region of a continuous casting mold independently from the stirring induced within the remaining volume of the mold by a main electromagnetic stirrer (M-EMS). This control is achieved by applying to the meniscus region an auxiliary electromagnetic field whose direction of rotation is opposite to that of the main magnetic field produced by the M-EMS. The model computes values and spatial distributions of electromagnetic parameters and fluid flow in the stirred pools of mercury in cylindrical and square geometries. Also predicted are the relationships between electromagnetics and fluid flows pertinent to a dynamic equilibrium of the opposing stirring swirls in the meniscus region. Results of the numerical simulation compared well with measurements obtained from experiments with mercury pools.

  10. Compact, Low-Noise Magnetic Sensor with Fluxgate (DC) and Induction (AC) Modes of Operation

    DTIC Science & Technology

    2009-07-01

    complete bi-polar cycle, and 20 stacked measurements are selected. Two obstacles to dual-mode operation are magnetic hysteresis in the ferrite cores and...13 Figure 5.2 - Dual mode receiver probe. Left: a photo of the 3-axis probe; Right: details of the probe. Two ferrite core excitation coils...response of coil #1 with different core materials (a) Nanocrystalline bar; (b) Ferrite 78 rods; (c) P-1103 rods

  11. ac susceptibility studies of magnetic relaxation in nanoparticles of Ni dispersed in silica

    NASA Astrophysics Data System (ADS)

    Singh, V.; Seehra, M. S.; Bonevich, J.

    2009-04-01

    Temperature dependence of ac susceptibilities χ' and χ″ are reported using frequencies fm=0.1, 1, 99, 499, and 997 Hz for nanoparticles of Ni dispersed in silica (Ni/SiO2:15/85) with the mean sizes D =3.8, 11.7, 15, and 21 nm (σ ≃0.2 nm), as determined by transmission electron microscopy. The blocking temperatures TB, as determined by peaks in χ″ versus T data, are fit to the Vogel-Fulcher law based on the following equation: TB=To+Ta/ln(fo/fm). Using the attempt frequency fo=1.82×1010 Hz, Ta (K)=310 (21), 954(17), 1334(14), and 1405(47) are determined for D =3.8, 11.7, 15, and 21 nm, respectively, along with To (representing the interparticle interaction)=0, 0, 6.6(0.7), and 12.5(2.5) K respectively. The magnitudes of Ta=KaV/k yield the anisotropy constant Ka increasing with decreasing D (or volume V) due to contributions from surface anisotropy. The validity of the theoretical result χ″=C∂(χ'T)/∂T with C ≃π/[2 ln(fo/2πfm)] is checked and the calculated values of fo are consistent with experimental value of fo=1.82×1010 Hz.

  12. Ac-susceptibility investigations of superspin blocking and freezing in interacting magnetic nanoparticle ensembles

    NASA Astrophysics Data System (ADS)

    Botez, Cristian E.; Morris, Joshua L.

    2016-03-01

    We have investigated the effect of dipolar interactions on the superspin blocking and freezing of 9 nm average size Fe3O4 magnetic nanoparticle ensembles. Our dynamic susceptibility data reveals a two-regime behavior of the blocking temperature, T B, upon diluting a Fe3O4/hexane magnetic fluid. As the nanoparticle volume ratio, Φ, is reduced from an as-prepared reference Φ = 1 to Φ = 1/96, the blocking temperature decreases from 46.1 K to 34.2 K, but higher values reenter upon further diluting the magnetic fluid to Φ = 1/384 (where T B = 42.5 K). We found evidence that cooling below T B within the higher concentration range (Φ > 1/48) leads to the collective freezing of the superspins, whereas individual superspin blocking occurs in the presence of weaker interactions (Φ < 1/96). The unexpected increase of the blocking temperature with the decrease of the inter-particle interactions observed at low nanoparticle concentrations is well described by the Mørup-Tronc model.

  13. Low temperature magnetic ground state in bulk Co0.3Zn0.7Fe2O4 spinel ferrite system: Neutron diffraction, magnetization and ac-susceptibility studies

    NASA Astrophysics Data System (ADS)

    Parmar, Harshida; Acharya, Prashant; Upadhyay, R. V.; Siruguri, V.; Rayaprol, Sudhindra

    2013-01-01

    The system under study is a bulk Co0.3Zn0.7Fe2O4 ferrite, synthesized by wet chemical route technique and having magnetic in-homogeneity at the microscopic scale, due to the concentration of magnetic ion at a tetrahedral site below the site percolation threshold for the ferrimagnetic ordering. To unravel the magnetic ground state of this system, low temperature neutron diffraction, magnetization and ac-susceptibility measurements were carried out. In the temperature-dependent neutron diffraction analysis, a diffused scattering signal appears at the low Q region below (1 1 1) magnetic Bragg peak at all temperature, indicating the presence of a finite magnetic cluster with infinite magnetic network. The diffused scattering signal intensity decreases with increases in magnetic field at T=10 K. The ac-susceptibility measurement exhibits three peak behavior in χ' and χ″ indicating the presence of finite magnetic clusters and cluster-cluster interaction in the system. The absence of magnetic (2 0 0) peak in neutron diffraction at 2 K and bifurcation of zero field and field cooled magnetization indicate the phase transition from uniaxial random ferromagnetic (URF) phase to semi spin glass or canted random ferromagnetic (CRF) phase in the system with temperature.

  14. Photoconductivity in AC-driven modulated two-dimensional electron gas in a perpendicular magnetic field.

    PubMed

    Torres, Manuel; Kunold, Alejandro

    2006-04-26

    In this work we study the microwave photoconductivity of a two-dimensional electron system (2DES) in the presence of a magnetic field and a two-dimensional modulation (2D). The model includes the microwave and Landau contributions in a non-perturbative exact way; the periodic potential is treated perturbatively. The Landau-Floquet states provide a convenient base with respect to which the lattice potential becomes time dependent, inducing transitions between the Landau-Floquet levels. Based on this formalism, we provide a Kubo-like formula that takes into account the oscillatory Floquet structure of the problem. The total longitudinal conductivity and resistivity exhibit strong oscillations, determined by ϵ = ω/ω(c), with ω the radiation frequency and ω(c) the cyclotron frequency. The oscillations follow a pattern with minima centred at [Formula: see text], and maxima centred at [Formula: see text], where j = 1,2,3..., δ∼1/5 is a constant shift and l is the dominant multipole contribution. Negative resistance states (NRSs) develop as the electron mobility and the intensity of the microwave power are increased. These NRSs appear in a narrow window region of values of the lattice parameter (a), around a∼l(B), where l(B) is the magnetic length. It is proposed that these phenomena may be observed in artificially fabricated arrays of periodic scatterers at the interface of ultraclean GaAs /Al(x)Ga(1-x)As heterostructures.

  15. Chemical reduction synthesis and ac field effect of iron based core-shell magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Balakrishnan, Srinivasan; Bonder, Michael J.; Hadjipanayis, George C.

    2009-12-01

    High magnetization nanoparticles coated with a biocompatible polymer have attracted considerable interest in recent times as potential materials for biomedical applications associated with targeted drug delivery, detection and the treatment of cancer. This paper considers the use of sodium borohydride reduction of metal salts to form Fe based nanoparticles coated with carboxyl terminated polyethylene glycol (cPEG). By mixing the reactants in a Y-junction, the synthesis produces uniform nanoparticles in the size range 10-20 nm with a core-shell structure. The particles are subsequently coated with a 1-3 nm thick layer of cPEG. These nanoparticles are soft ferromagnets with Hc = 400 Oe. Exciting these nanoparticles with a 4 Oe, 500 kHz alternating magnetic field leads to particle heating with a maximal increase in the saturation temperature as the particle size is decreased. For the largest particles considered here, the temperature reaches 35 °C with a 10 mg sample mass whilst for the smallest nanoparticles considered the temperature exceeds 40 °C.

  16. Granularity and vortex dynamics in LaFeAsO0.92F0.08 probed by harmonics of the ac magnetic susceptibility

    NASA Astrophysics Data System (ADS)

    Polichetti, Massimiliano; Adesso, Maria G.; Zola, Danilo; Luo, Jianlin; Chen, G. F.; Li, Zheng; Wang, N. L.; Noce, Canio; Pace, Sandro

    2008-12-01

    Fundamental and higher harmonics of the ac magnetic susceptibility have been measured on LaFeAsO0.92F0.08 samples as a function of the temperature, at various amplitudes and frequencies of the ac magnetic field, with a small superimposed dc field parallel to the ac field. The granularity of the samples has been investigated and the intergrain and intragrain contributions have been clearly individuated looking at both the first and the third harmonics. The vortex dynamics has been also analyzed, and a comparison with the magnetic behavior of both the MgB2 and the cuprate superconductors has been performed. Some vortex dissipative phenomena, i.e., the thermally activated flux flow and the flux creep, have been detected in the presented experimental data, similar to what have been obtained on YBCO. Nevertheless, although the general behavior is similar, several differences have been also evidenced between these different classes of superconductors, mainly in the third harmonics. We infer that different vortex dynamics has to be included into the analysis of the magnetic response in this iron-based material.

  17. Effect of Si addition on AC and DC magnetic properties of (Fe-P)-Si alloy

    NASA Astrophysics Data System (ADS)

    Gautam, Ravi; Prabhu, D.; Chandrasekaran, V.; Gopalan, R.; Sundararajan, G.

    2016-05-01

    We report a new (Fe-P)-Si based alloy with relatively high induction (1.8-1.9 T), low coercivity (< 80 A/m), high resistivity (˜38 μΩ cm) and low core loss (217 W/kg @ 1 T/1 kHz) comparable to the commercially available M530-50 A5 Si-steel. The attractive magnetic and electrical properties are attributed to i) the two phase microstructure of fine nano precipitates of Fe3P dispersed in α-Fe matrix achieved by a two-step heat-treatment process and ii) Si addition enhancing the resistivity of the α-Fe matrix phase. As the alloy processing is by conventional wrought metallurgy method, it has the potential for large scale production.

  18. Three-dimensional structural changes in living hippocampal neurons imaged using magnetic AC mode atomic force microscopy.

    PubMed

    Yunxu, Sun; Danying, Lin; Yanfang, Rui; Dong, Han; Wanyun, Ma

    2006-06-01

    We developed the magnetic AC (MAC) mode atomic force microscopy (AFM) to image the 3D ultrastructure of living hippocampal neurons under physiological conditions. Initially, the soma, the dendrites and the growth cones of hippocampal neurons were imaged. The imaging force was adjusted to a small value for the long-term observation. The neural spines were damaged when the tip produced a large force; the spines regenerated after the force was reduced. Subsequently, we explored the relationship between structural changes in hippocampal neurons and Alzheimer's disease by employing the new imaging technique. Time-lapse image acquisition (10 min intervals) showed that the growth cone collapsed after the addition amyloid peptide fragment beta(25-35), which is thought to initiate Alzheimer's disease. In addition, we found substantial changes in mechanical properties and in the volume of individual growth cone. This study suggested that MAC mode AFM may be a powerful tool for observing long-term structural changes in living neural cells under physiological conditions.

  19. Successive superconducting transitions in Ta2S2C studied by electrical resistivity and nonlinear ac magnetic susceptibility

    NASA Astrophysics Data System (ADS)

    Suzuki, Masatsugu; Suzuki, Itsuko S.; Noji, Takashi; Koike, Yoji; Walter, Jürgen

    2007-05-01

    Ta2S2C compound undergoes superconducting transitions at Tcl=3.60±0.02K and Tcu=9.0±0.2K . The nature of successive superconducting transitions has been studied from electrical resistivity and linear and nonlinear ac magnetic susceptibilities. The resistivity ρ at H=0 shows a local maximum near Tcu , a kinklike behavior around Tcl , and reduces to zero at below T0=2.1K . The lnT dependence of ρ is observed at H=50kOe at low temperatures, which is due to a two-dimensional weak-localization effect. Below Tcu , a two-dimensional superconducting phase occurs in each TaC layer. The linear and nonlinear susceptibilities χ1″ , χ3' , χ5' , and χ7' as well as the difference δχ (=χFC-χZFC) between the field-cooled (FC) and zero-field-cooled (ZFC) susceptibilities start to appear below 6.0K , the onset temperature of irreversibility. A drastic growth of the in-plane superconducting coherence length below 6.0K gives rise to a three-dimensional superconducting phase below Tcl through interplanar Josephson couplings between adjacent TaC layers. The oscillatory behavior of χ3″ , χ5″ , and χ7″ below Tcl is related to the nonlinear behavior arising from the thermally activated flux flow.

  20. Steady laminar mixed convection stagnation-point flow of a nanofluid over a vertical permeable surface in the presence of a magnetic field

    NASA Astrophysics Data System (ADS)

    Tamim, H.; Dinarvand, S.; Hosseini, R.; Rahimi, H.; Pop, I.

    2016-11-01

    A similarity solution for a steady laminar mixed convection boundary layer flow of a nanofluid near the stagnation point on a vertical permeable plate with a magnetic field and a buoyancy force is obtained by solving a system of nonlinear ordinary differential equations. These equations are solved analytically by using a new kind of a powerful analytic technique for nonlinear problems, namely, the homotopy analysis method (HAM). Three different types of nanoparticles, namely, copper (Cu), alumina (Al2O3), and titanium oxide (TiO2), with water as the base fluid are considered. The influence of the volume fraction of nanoparticles, permeability parameter, magnetic parameter, and mixed convection parameter on the surface shear stress and surface heat transfer, as well as on the velocity and temperature profiles, is considered. It is observed that the skin friction coefficient and the local Nusselt number increase with the nanoparticle volume fraction for all types of nanoparticles considered in this study. The greatest values of the skin friction coefficient and the local Nusselt number are obtained for Cu nanoparticles.

  1. Advanced single permanent magnet axipolar ironless stator ac motor for electric passenger vehicles

    NASA Technical Reports Server (NTRS)

    Beauchamp, E. D.; Hadfield, J. R.; Wuertz, K. L.

    1983-01-01

    A program was conducted to design and develop an advanced-concept motor specifically created for propulsion of electric vehicles with increased range, reduced energy consumption, and reduced life-cycle costs in comparison with conventional systems. The motor developed is a brushless, dc, rare-earth cobalt, permanent magnet, axial air gap inductor machine that uses an ironless stator. Air cooling is inherent provided by the centrifugal-fan action of the rotor poles. An extensive design phase was conducted, which included analysis of the system performance versus the SAE J227a(D) driving cycle. A proof-of-principle model was developed and tested, and a functional model was developed and tested. Full generator-level testing was conducted on the functional model, recording electromagnetic, thermal, aerodynamic, and acoustic noise data. The machine demonstrated 20.3 kW output at 1466 rad/s and 160 dc. The novel ironless stator demonstated the capability to continuously operate at peak current. The projected system performance based on the use of a transistor inverter is 23.6 kW output power at 1466 rad/s and 83.3 percent efficiency. Design areas of concern regarding electric vehicle applications include the inherently high windage loss and rotor inertia.

  2. Single phase bi-directional AC-DC converter with reduced passive components size and common mode electro-magnetic interference

    DOEpatents

    Mi, Chris; Li, Siqi

    2017-01-31

    A bidirectional AC-DC converter is presented with reduced passive component size and common mode electro-magnetic interference. The converter includes an improved input stage formed by two coupled differential inductors, two coupled common and differential inductors, one differential capacitor and two common mode capacitors. With this input structure, the volume, weight and cost of the input stage can be reduced greatly. Additionally, the input current ripple and common mode electro-magnetic interference can be greatly attenuated, so lower switching frequency can be adopted to achieve higher efficiency.

  3. Magnetic behavior of as-deposited and annealed CoFe and CoFeCu nanowire arrays by ac-pulse electrodeposition

    NASA Astrophysics Data System (ADS)

    Ramazani, A.; Almasi-Kashi, M.; Golafshan, E.; Arefpour, M.

    2014-09-01

    CoFe and CoFeCu self-organized alloy nanowires were grown into anodic aluminum oxide template by potentiostatic mode of ac-pulse electrodeposition technique and subsequently annealed at 580 °C. The influence of bath composition, off-time between pulses and annealing treatment on the Cu content, microstructure and magnetic properties of CoFeCu nanowire arrays have been discussed. Increasing the off-time between pulses decreased the coercivity and saturation magnetization of the CoFeCu nanowires due to substitution of Co and Fe with Cu atoms which resulted in electroless process. Coercivity and squareness of the annealed samples increased due to improvement of samples crystallinity. Magnetic measurements showed high perpendicular magnetic anisotropy of the nanowires with easy axis parallel to nanowires axis. X-ray diffraction results indicated that annealed CoFeCu nanowires were polycrystalline with two distinct CoFe and Cu phases.

  4. Determination of the magnetic ground state in the martensite phase of Ni-Mn-Z (Z = In, Sn and Sb) off-stoichiometric Heusler alloys by nonlinear AC susceptibility.

    PubMed

    Umetsu, R Y; Fujita, A; Ito, W; Kanomata, T; Kainuma, R

    2011-08-17

    DC and AC magnetic measurements were carried out to clarify the difference in the magnetic ground state depending on the kinds of Z element used in the martensite phase in Ni-Mn-Z (Z = In, Sn and Sb) off-stoichiometric Heusler alloys. Magnetic field cooling effects were observed in the DC thermomagnetization curves in the low temperature regions, and a frequency dependence on AC susceptibility was also observed in both real and imaginary parts of the susceptibility. Negative divergence was clearly observed in nonlinear AC susceptibility only for the Ni(50)Mn(40)Sb(10) alloy, suggesting that the magnetic feature of its ground state is the spin-glass state. The magnetic ground state of the martensite phase in these alloys would relate to the magnetic configuration of the Mn atoms in the ferromagnetic austenite phase.

  5. Automated ac galvanomagnetic measurement system

    NASA Technical Reports Server (NTRS)

    Szofran, F. R.; Espy, P. N.

    1985-01-01

    An automated, ac galvanomagnetic measurement system is described. Hall or van der Pauw measurements in the temperature range 10-300 K can be made at a preselected magnetic field without operator attendance. Procedures to validate sample installation and correct operation of other system functions, such as magnetic field and thermometry, are included. Advantages of ac measurements are discussed.

  6. Synthesis of Micelles Guided Magnetite (Fe3O4) Hollow Spheres and their application for AC Magnetic Field Responsive Drug Release.

    PubMed

    Mandal Goswami, Madhuri

    2016-10-31

    This paper reports on synthesis of hollow spheres of magnetite, guided by micelles and their application in drug release by the stimulus responsive technique. Here oleyelamine micelles are used as the core substance for the formation of magnetite nano hollow spheres (NHS). Diameter and shell thickness of NHS have been changed by changing concentration of the micelles. Mechanism of NHS formation has been established by investigating the aliquot collected at different time during the synthesis of NHS. It has been observed that oleyelamine as micelles play an important role to generate hollow-sphere particles of different diameter and thickness just by varying its amount. Structural analysis was done by XRD measurement and morphological measurements, SEM and TEM were performed to confirm the shape and size of the NHS. FTIR measurement support the formation of magnetite phase too. Frequency dependent AC magnetic measurements and AC magnetic field stimulated drug release event by these particles provide a direction of the promising application of these NHS for better cancer treatment in near future. Being hollow &porous in structure and magnetic in nature, such materials will also be useful in other applications such as in removal of toxic materials, magnetic separation etc.

  7. Synthesis of Micelles Guided Magnetite (Fe3O4) Hollow Spheres and their application for AC Magnetic Field Responsive Drug Release

    PubMed Central

    Mandal Goswami, Madhuri

    2016-01-01

    This paper reports on synthesis of hollow spheres of magnetite, guided by micelles and their application in drug release by the stimulus responsive technique. Here oleyelamine micelles are used as the core substance for the formation of magnetite nano hollow spheres (NHS). Diameter and shell thickness of NHS have been changed by changing concentration of the micelles. Mechanism of NHS formation has been established by investigating the aliquot collected at different time during the synthesis of NHS. It has been observed that oleyelamine as micelles play an important role to generate hollow-sphere particles of different diameter and thickness just by varying its amount. Structural analysis was done by XRD measurement and morphological measurements, SEM and TEM were performed to confirm the shape and size of the NHS. FTIR measurement support the formation of magnetite phase too. Frequency dependent AC magnetic measurements and AC magnetic field stimulated drug release event by these particles provide a direction of the promising application of these NHS for better cancer treatment in near future. Being hollow & porous in structure and magnetic in nature, such materials will also be useful in other applications such as in removal of toxic materials, magnetic separation etc. PMID:27796329

  8. Effect of ordered array of magnetic dots on the dynamics of Josephson vortices in stacked SNS Josephson junctions under DC and AC current

    NASA Astrophysics Data System (ADS)

    Berdiyorov, Golibjon R.; Savel'ev, Sergey; Kusmartsev, Feodor V.; Peeters, François M.

    2015-11-01

    We use the anisotropic time-dependent Ginzburg-Landau theory to investigate the effect of a square array of out-of-plane magnetic dots on the dynamics of Josephson vortices (fluxons) in artificial stacks of superconducting-normal-superconducting (SNS) Josephson junctions in the presence of external DC and AC currents. Periodic pinning due to the magnetic dots distorts the triangular lattice of fluxons and results in the appearance of commensurability features in the current-voltage characteristics of the system. For the larger values of the magnetization, additional peaks appear in the voltage-time characteristics of the system due to the creation and annihilation of vortex-antivortex pairs. Peculiar changes in the response of the system to the applied current is found resulting in a "superradiant" vortex-flow state at large current values, where a rectangular lattice of moving vortices is formed. Synchronizing the motion of fluxons by adding a small ac component to the biasing dc current is realized. However, we found that synchronization becomes difficult for large magnetization of the dots due to the formation of vortex-antivortex pairs.

  9. Synthesis of Micelles Guided Magnetite (Fe3O4) Hollow Spheres and their application for AC Magnetic Field Responsive Drug Release

    NASA Astrophysics Data System (ADS)

    Mandal Goswami, Madhuri

    2016-10-01

    This paper reports on synthesis of hollow spheres of magnetite, guided by micelles and their application in drug release by the stimulus responsive technique. Here oleyelamine micelles are used as the core substance for the formation of magnetite nano hollow spheres (NHS). Diameter and shell thickness of NHS have been changed by changing concentration of the micelles. Mechanism of NHS formation has been established by investigating the aliquot collected at different time during the synthesis of NHS. It has been observed that oleyelamine as micelles play an important role to generate hollow-sphere particles of different diameter and thickness just by varying its amount. Structural analysis was done by XRD measurement and morphological measurements, SEM and TEM were performed to confirm the shape and size of the NHS. FTIR measurement support the formation of magnetite phase too. Frequency dependent AC magnetic measurements and AC magnetic field stimulated drug release event by these particles provide a direction of the promising application of these NHS for better cancer treatment in near future. Being hollow & porous in structure and magnetic in nature, such materials will also be useful in other applications such as in removal of toxic materials, magnetic separation etc.

  10. New petrophysical magnetic methods MACC and MAFM in permeability characterisation of petroleum reservoir rock cleaning, flooding modelling and determination of fines migration in formation damage

    NASA Astrophysics Data System (ADS)

    Ivakhnenko, O. P.

    2012-04-01

    Potential applications of magnetic techniques and methods in petroleum engineering and petrophysics (Ivakhnenko, 1999, 2006; Ivakhnenko & Potter, 2004) reveal their vast advantages for the petroleum reservoir characterisation and formation evaluation. In this work author proposes for the first time developed systematic methods of the Magnetic Analysis of Core Cleaning (MACC) and Magnetic Analysis of Fines Migration (MAFM) for characterisation of reservoir core cleaning and modelling estimations of fines migration for the petroleum reservoir formations. Using example of the one oil field we demonstrate results in application of these methods on the reservoir samples. Petroleum reservoir cores samples have been collected within reservoir using routine technique of reservoir sampling and preservation for PVT analysis. Immediately before the MACC and MAFM studies samples have been exposed to atmospheric air for a few days. The selected samples have been in detailed way characterised after fluid cleaning and core flooding by their mineralogical compositions and petrophysical parameters. Mineralogical composition has been estimated utilizing XRD techniques. The petrophysical parameters, such as permeability and porosity have been measured on the basis of total core analysis. The results demonstrate effectiveness and importance of the MACC and MAFM methods for the routine core analysis (RCAL) and the special core analysis (SCAL) in the reservoir characterisation, core flooding and formation damage analysis.

  11. Heat generation ability in AC magnetic field of nano MgFe2O4-based ferrite powder prepared by bead milling

    NASA Astrophysics Data System (ADS)

    Hirazawa, Hideyuki; Aono, Hiromichi; Naohara, Takashi; Maehara, Tsunehiro; Sato, Mitsunori; Watanabe, Yuji

    2011-03-01

    Nanosized MgFe2O4-based ferrite powder having heat generation ability in an AC magnetic field was prepared by bead milling and studied for thermal coagulation therapy applications. The crystal size and the particle size significantly decreased by bead milling. The heat generation ability in an AC magnetic field improved with the milling time, i.e. a decrease in crystal size. However, the heat generation ability decreased for excessively milled samples with crystal sizes of less than 5.5 nm. The highest heat ability (ΔT=34 °C) in the AC magnetic field (370 kHz, 1.77 kA/m) was obtained for fine MgFe2O4 powder having a ca. 6 nm crystal size (the samples were milled for 6-8 h using 0.1 mm ϕ beads). The heat generation of the samples was closely related to hysteresis loss, a B-H magnetic property. The reason for the high heat generation properties of the samples milled for 6-8 h using 0.1 mm ϕ beads was ascribed to the increase in hysteresis loss by the formation of a single domain. Moreover, the improvement in heating ability was obtained by calcination of the bead-milled sample at low temperature. In this case, the maximum heat generation (ΔT=41 °C) ability was obtained for a ca. 11 nm crystal size sample was prepared by crystal growth during the sample calcination. On the other hand, the ΔT value for Mg0.5Ca0.5Fe2O4 was synthesized using a reverse precipitation method decreased by bead milling.

  12. Vortex dynamics and irreversibility line in optimally doped SmFeAsO0.8F0.2 from ac susceptibility and magnetization measurements

    NASA Astrophysics Data System (ADS)

    Prando, G.; Carretta, P.; de Renzi, R.; Sanna, S.; Palenzona, A.; Putti, M.; Tropeano, M.

    2011-05-01

    Ac susceptibility and static magnetization measurements were performed in the optimally doped SmFeAsO0.8F0.2 superconductor. The field-temperature phase diagram of the superconducting state was drawn, and, in particular, the features of the flux lines were derived. The dependence of the intragrain depinning energy on the magnetic field intensity was derived in the thermally activated flux-creep framework, enlightening a typical 1/H dependence in the high-field regime. The intragrain critical current density was extrapolated in the zero-temperature and zero-magnetic-field limit, showing a remarkably high value Jc0(0)~2×107 A/cm2, which demonstrates that this material is rather interesting for potential future technological applications.

  13. Magnetic AC loss of a mono-Sr0.6K0.4Fe2As2 tape/Ag in perpendicular field

    NASA Astrophysics Data System (ADS)

    Liu, Qi; Zhang, Guomin; Yu, Hui; Huang, Miaomiao; Yuan, Weijia

    2016-12-01

    The magnetic AC losses of monofilament Sr0.6K0.4Fe2As2/Ag tapes are measured in the temperature range between 20 K and 30 K both in perpendicular and parallel field. The loss, measured by the standard magnetization technique, is determined from the area of the hysteresis loop using a vibrating sample magnetometer (VSM) in a cyclic field of amplitude up to 7 T. The results in perpendicular field are compared to that of the parallel-field loss and theoretical calculation of magnetization loss at various temperatures. There is a reasonable agreement between the theoretical model and the experimental results even in high field. The magnetic critical current density (Jc) of the tape, obtained by the magnetic hysteresis measurements M(H), are investigated in two field directions and in the temperature range from 5 K to 30 K. The comparison between the magnetic Jc in both field directions and the transport Jc of the tape are also done at various temperatures and fields. The anisotropy of Jc (Γ = Jcab /Jcc) is very small.

  14. Pulsatile drug release from PLGA hollow microspheres by controlling the permeability of their walls with a magnetic field.

    PubMed

    Chiang, Wei-Lun; Ke, Cherng-Jyh; Liao, Zi-Xian; Chen, San-Yuan; Chen, Fu-Rong; Tsai, Chun-Ying; Xia, Younan; Sung, Hsing-Wen

    2012-12-07

    Pulsatile release: When a high-frequency magnetic field is applied, heat will be generated by coupling to the iron oxide nanoparticles encapsulated in the shells of PLGA hollow microspheres. As the temperature approaches the T(g) of PLGA, the polymer chains become more mobile, subsequently increasing the free volume of PLGA matrix and significantly enhancing the diffusion of drug molecules.

  15. Tevatron AC dipole system

    SciTech Connect

    Miyamoto, R.; Kopp, S.E.; Jansson, A.; Syphers, M.J.; /Fermilab

    2007-06-01

    The AC dipole is an oscillating dipole magnet which can induce large amplitude oscillations without the emittance growth and decoherence. These properties make it a good tool to measure optics of a hadron synchrotron. The vertical AC dipole for the Tevatron is powered by an inexpensive high power audio amplifier since its operating frequency is approximately 20 kHz. The magnet is incorporated into a parallel resonant system to maximize the current. The use of a vertical pinger magnet which has been installed in the Tevatron made the cost relatively inexpensive. Recently, the initial system was upgraded with a more powerful amplifier and oscillation amplitudes up to 2-3{sigma} were achieved with the 980 GeV proton beam. This paper discusses details of the Tevatron AC dipole system and also shows its test results.

  16. Molecular packing and magnetic properties of lithium naphthalocyanine crystals: hollow channels enabling permeability and paramagnetic sensitivity to molecular oxygen

    PubMed Central

    Pandian, Ramasamy P.; Dolgos, Michelle; Marginean, Camelia; Woodward, Patrick M.; Hammel, P. Chris; Manoharan, Periakaruppan T.; Kuppusamy, Periannan

    2009-01-01

    The synthesis, structural framework, magnetic and oxygen-sensing properties of a lithium naphthalocyanine (LiNc) radical probe are presented. LiNc was synthesized in the form of a microcrystalline powder using a chemical method and characterized by electron paramagnetic resonance (EPR) spectroscopy, magnetic susceptibility, powder X-ray diffraction analysis, and mass spectrometry. X-Ray powder diffraction studies revealed a structural framework that possesses long, hollow channels running parallel to the packing direction. The channels measured approximately 5.0 × 5.4 Å2 in the two-dimensional plane perpendicular to the length of the channel, enabling diffusion of oxygen molecules (2.9 × 3.9 Å2) through the channel. The powdered LiNc exhibited a single, sharp EPR line under anoxic conditions, with a peak-to-peak linewidth of 630 mG at room temperature. The linewidth was sensitive to surrounding molecular oxygen, showing a linear increase in pO2 with an oxygen sensitivity of 31.2 mG per mmHg. The LiNc microcrystals can be further prepared as nano-sized crystals without the loss of its high oxygen-sensing properties. The thermal variation of the magnetic properties of LiNc, such as the EPR linewidth, EPR intensity and magnetic susceptibility revealed the existence of two different temperature regimes of magnetic coupling and hence differing columnar packing, both being one-dimensional antiferromagnetic chains but with differing magnitudes of exchange coupling constants. At a temperature of ∼50 K, LiNc crystals undergo a reversible phase transition. The high degree of oxygen-sensitivity of micro- and nano-sized crystals of LiNc, combined with excellent stability, should enable precise and accurate measurements of oxygen concentration in biological systems using EPR spectroscopy. PMID:19809598

  17. Hydrostatic Pressure Study on 3-K Phase Superconductivity in Sr2RuO4-Ru Eutectic Crystals by AC Magnetic Susceptibility Measurements

    NASA Astrophysics Data System (ADS)

    Yaguchi, Hiroshi; Watanabe, Hiromichi; Sakaue, Akira

    2012-12-01

    We have investigated the effect of hydrostatic pressure on 3-K phase superconductivity in Sr2RuO4-Ru eutectic crystals by means of AC magnetic susceptibility measurements. We have found that the application of hydrostatic pressure suppresses the superconducting transition temperature Tc of the 3-K phase with a pressure coefficient of dTc/dP ≈ -0.2 K/GPa, similar to the case of the 1.5-K phase. We have also observed that the effect of hydrostatic pressure on the 3-K phase seems to be elastic whilst that of uniaxial pressure is plastic.

  18. Calibrating NMR measured porosity/permeability relationships using µXRCT measurements

    NASA Astrophysics Data System (ADS)

    Mason, H. E.; Smith, M. M.; Hao, Y.; Carroll, S.

    2015-12-01

    Carbonate reservoirs have garnered interest for potential use in carbon capture and storage (CCS) activities. To be suitable for long term carbon dioxide (CO2) storage, they must possess sufficient permeability either through existing connected pore space, or due to reactivity with CO2-acidified fluids. Adequate assessment of the target formation permeability will rely on accurate downhole well-logging tools. Primary among these tools is nuclear magnetic resonance (NMR) well-logging. Application of this tool relies on our ability to relate the porosity and pore distributions measured by NMR to permeability. These methods are challenging to apply in carbonate reservoirs with complex mineralogies where pores sizes often span orders of magnitudes. We have assessed the ability of NMR methods to measure permeability using rocks from the Weyburn-Midale CO2 Monitoring and Storage Project Saskatchewan, Canada and the Arbuckle injection zone at the Wellington CO2 storage demonstration site, Kansas. Results of laboratory measured permeability values of these rocks indicate that the standard NMR methods for predicting permeability values can produce values off by orders of magnitude within the same flow units. In this presentation, we present the results of a combined NMR and micro X-ray computed tomography (μXRCT) study of these rock cores to better estimate downhole permeability values of carbonate rocks. The results of the study suggest that the dramatic differences in predicted permeability values derive from large differences in the matrix porosity, pore network tortuosities, and mineralogy of the various rock units. We will present new laboratory measurements, and methodologies aimed at producing a universal NMR calibration procedure for determining permeability in carbonate reservoirs. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  19. Numerical investigation of MHD stagnation point flow and heat transfer over a permeable shrinking sheet with external magnetic field, viscous dissipation and Joule heating

    NASA Astrophysics Data System (ADS)

    Jafar, Khamisah; Nazar, Roslinda; Ishak, Anuar; Pop, Ioan

    2012-05-01

    The present study considers the steady laminar magnetohydrodynamic (MHD) boundary layer flow of a viscous and incompressible electrically conducting fluid near the stagnation point on a horizontal continuously shrinking surface, with variable wall temperature and a constant magnetic field applied normal to the surface of the sheet. The surface is assumed to be permeable, allowing either suction or injection at the wall. By introducing an appropriate similarity transformation, the governing system of partial differential equations is first transformed into a system of ordinary differential equations, which is then solved numerically using an implicit finite-difference scheme known as the Keller-box method for some values of the selected parameters. The effects of the governing parameters, namely the shrinking parameter λ, the suction parameter f0 and the magnetic parameter M on the skin friction coefficient, the local Nusselt number as well as the velocity and temperature profiles are determined and discussed. For the present study, the analysis is limited to the case where the Prandtl number is fixed at unity, i.e. Pr = 1 and the Eckert number, Ec = 0.5. It is found that solutions for the shrinking sheet only exist when the magnitude of the shrinking parameter is less than some limiting critical value λc. Where solutions do exist, they are either a unique solution or dual solutions, and for large enough suction at the wall, there may even be triple solutions. For the shrinking sheet, in the presence of viscous dissipation and Joule heating, the magnetic field increases the surface shear stress and slightly increases the surface heat transfer rate.

  20. The use of field dependence of AC susceptibility for the interpretation of magnetic mineralogy and magnetic fabrics in the HSDP-2 basalts, Hawaii [rapid communication

    NASA Astrophysics Data System (ADS)

    Vahle, Carsten; Kontny, Agnes

    2005-09-01

    We applied the field dependence parameter χHd (%) = [( k300A/m - k30A/m) / k300A/m] × 100 given by de Wall for the subaerial and submarine basalts drilled by the 3109 m deep HSDP-2 borehole on Hawaii in order to verify the hypothesis that mainly composition controls the field dependence of AC susceptibility in titanomagnetite of natural occurrences. When we used this parameter, our data showed a significant scattering compared to data presented in earlier studies. In addition to composition, the effect of measurement temperature, grain size and anisotropy on the field dependent susceptibility were examined and found to be critical. The impact of grain size is weaker than the other effects. It cannot be totally excluded that the observed effects arise indirectly through an overlap of the other effects for the investigated basalts. The most important factor for the variation of field dependence is the degree of oxidation, causing a modification of the titanomagnetite composition or formation of titanomaghemite, and the mixing of Ti-rich with Ti-poor titanomagnetites, which strongly reduces the χHd parameter. Field dependence is not only related to titanomagnetite composition, especially for intermediate titanomagnetites with TCs between 100 and 300 °C. Temperature dependent susceptibility measurements at different field amplitudes for these intermediate types showed at constant geometry of the k( T) curve great differences in susceptibility, resulting in significant changes of the field dependence parameter over the temperature interval from - 100 to 260 °C. Therefore variations of the ambient measurement temperatures are able to influence the field dependence. The second important effect is the degree of particle shape and alignment, which controls the field dependence in different orientations especially for the intermediate titanomagnetite, which is intensively intergrown with elongated hemoilmenite grains. As a consequence, samples with higher degrees of

  1. Vortex flux dynamics and harmonic ac magnetic response of Ba(Fe0.94Ni0.06)2As2 bulk superconductor

    SciTech Connect

    Nikolo, Martin; Zapf, Vivien S.; Singleton, John; Jiang, Jianyi; Weiss, Jeremy D.; Hellstrom, Eric E.

    2016-07-22

    Vortex dynamics and nonlinear ac response are studied in a Ba(Fe0.94Ni0.06)2As2(Tc= 18.5 K) bulk superconductor in magnetic fields up to 12 T via ac susceptibility measurements of the first ten harmonics. A comprehensive study of the ac magnetic susceptibility and its first ten harmonics finds shifts to higher temperatures with increasing ac measurement frequencies (10 to 10,000 Hz) for a wide range of ac (1, 5, and 10 Oe) and dc fields (0 to 12 T). The characteristic measurement time constant t1 is extracted from the exponential fit of the data and linked to vortex relaxation. The Anderson-Kim Arrhenius law is applied to determine flux activation energy Ea/k as a function dc magnetic field. The de-pinning, or irreversibility lines, were determined by a variety of methods and extensively mapped. The ac response shows surprisingly weak higher harmonic components, suggesting weak nonlinear behavior. Lastly, our data does not support the Fisher model; we do not see an abrupt vortex glass to vortex liquid transition and the resistivity does not drop to zero, although it appears to approach zero exponentially.

  2. Micelles driven magnetite (Fe3O4) hollow spheres and a study on AC magnetic properties for hyperthermia application

    NASA Astrophysics Data System (ADS)

    Goswami, Madhuri Mandal; Dey, Chaitali; Bandyopadhyay, Ayan; Sarkar, Debasish; Ahir, Manisha

    2016-11-01

    Here we have discussed about designing the magnetic particles for hyperthermia therapy and done some studies in this direction. We have used oleylamine micelles as template to synthesize hollow-nanospheres (HNS) of magnetite by solvo-thermal technique. We have shown that oleylamine plays an important role to generate hollow particles. Structural analysis was done by XRD measurement and morphological measurements like SEM and TEM was performed to confirm the shape and size of hollow sphere particles. The detail magnetic measurements give an idea about the application of these HNS for magnetic heating in hyperthermia therapy. In vitro cytotoxicity studies reveal that tolerable dose rate for these particles can be significantly high and particles are non-toxic in nature. Being hollow in structure and magnetic in nature such materials will also be useful in other application fields like in drug delivery, drug release, arsenic and heavy metal removal by adsorption technique, magnetic separation etc.

  3. Comparison of optomagnetic and AC susceptibility readouts in a magnetic nanoparticle agglutination assay for detection of C-reactive protein.

    PubMed

    Fock, Jeppe; Parmvi, Mattias; Strömberg, Mattias; Svedlindh, Peter; Donolato, Marco; Hansen, Mikkel Fougt

    2017-02-15

    There is an increasing need to develop biosensor methods that are highly sensitive and that can be combined with low-cost consumables. The use of magnetic nanoparticles (MNPs) is attractive because their detection is compatible with low-cost disposables and because application of a magnetic field can be used to accelerate assay kinetics. We present the first study and comparison of the performance of magnetic susceptibility measurements and a newly proposed optomagnetic method. For the comparison we use the C-reactive protein (CRP) induced agglutination of identical samples of 100nm MNPs conjugated with CRP antibodies. Both methods detect agglutination as a shift to lower frequencies in measurements of the dynamics in response to an applied oscillating magnetic field. The magnetic susceptibility method probes the magnetic response whereas the optomagnetic technique probes the modulation of laser light transmitted through the sample. The two techniques provided highly correlated results upon agglutination when they measure the decrease of the signal from the individual MNPs (turn-off detection strategy), whereas the techniques provided different results, strongly depending on the read-out frequency, when detecting the signal due to MNP agglomerates (turn-on detection strategy). These observations are considered to be caused by differences in the volume-dependence of the magnetic and optical signals from agglomerates. The highest signal from agglomerates was found in the optomagnetic signal at low frequencies.

  4. 8 π -periodic dissipationless ac Josephson effect on a quantum spin Hall edge via a quantum magnetic impurity

    NASA Astrophysics Data System (ADS)

    Hui, Hoi-Yin; Sau, Jay D.

    2017-01-01

    Time-reversal invariance places strong constraints on the properties of the quantum spin Hall edge. One such restriction is the inevitability of dissipation in a Josephson junction between two superconductors formed on such an edge without the presence of interaction. Interactions and spin-conservation breaking are key ingredients for the realization of the dissipationless ac Josephson effect on such quantum spin Hall edges. We present a simple quantum impurity model that allows us to create a dissipationless fractional Josephson effect on a quantum spin Hall edge. We then use this model to substantiate a general argument that shows that any such nondissipative Josephson effect must necessarily be 8 π periodic.

  5. Detail study on ac-dc magnetic and dye absorption properties of Fe3O4 hollow spheres for biological and industrial application.

    PubMed

    Sarkar, Debasish; Mandal, Kalyan; Mandal, Madhuri

    2014-03-01

    Here solvo-thermal technique has been used to synthesize hollow-nanospheres of magnetite. We have shown that PVP plays an important role to control the particle size and also helps the particles to take the shape of hollow spheres. Structural analysis was done by XRD measurement and morphological measurements like SEM and TEM were performed to confirm the hollow type spherical particles formation and their shape and sizes were also investigated. The detail ac-dc magnetic measurements give an idea about the application of these nano spheres for hyperthermia therapy and spontaneous dye adsorption properties (Gibbs free energy deltaG0 = -0.526 kJ/mol for Eosin and -1.832 kJ/mol for MB) of these particles indicate its use in dye manufacturing company. Being hollow in structure and magnetic in nature such materials will also be useful in other application fields like in drug delivery, arsenic and heavy metal removal by adsorption technique, magnetic separation etc.

  6. Experimental observation of further frequency upshift from dc to ac radiation converter with perpendicular dc magnetic field

    PubMed

    Higashiguchi; Yugami; Gao; Niiyama; Sasaki; Takahashi; Ito; Nishida

    2000-11-20

    A frequency upshift of a short microwave pulse is generated by the interaction between a relativistic underdense ionization front and a periodic electrostatic field with a perpendicular dc magnetic field. When the dc magnetic field is applied, further frequency upshift of 3 GHz is observed with respect to an unmagnetized case which has typically a GHz range. The radiation frequency depends on both the plasma density and the strength of the dc magnetic field, i.e., the plasma frequency and the cyclotron frequency. The frequency of the emitted radiation is in reasonable agreement with the theoretical values.

  7. Magnetic ordering in UCoNiSi2 and UCoCuSi2 studied by ac-susceptibility and neutron-diffraction measurements

    NASA Astrophysics Data System (ADS)

    Kuznietz, Moshe; Pinto, Haim; Melamud, Mordechai

    1994-05-01

    Polycrystalline samples of intermediate solid solutions of the UM2Si2 compounds (M=Co,Ni,Cu), namely UCoNiSi2 and UCoCuSi2, were prepared and were found to have body-centered tetragonal ThCr2Si2-type crystallographic structure. In UCoNiSi2 ac susceptibility indicates a single antiferromagnetic (AF) transition at TN=115±5 K, confirmed by neutron-diffraction observation of the AF-I structure down to 10 K (with uranium moments of 1.6±0.2μB, along the tetragonal c axis). In UCoCuSi2 ac susceptibility indicates ferromagnetic transition at TC=107±5 K, and implies an AF transition at lower temperature, confirmed by the AF-I structure, observed in neutron diffraction below T0=95±5 K down to 10 K (with uranium moments of 1.6±0.1μB, along the c axis). The magnetic properties are discussed in comparison with UM2X2 and U(M,M')2X2 materials (X=Si,Ge).

  8. Nitrogen Transformations in Three Types of Permeable Pavement

    EPA Science Inventory

    In 2009, USEPA constructed a 0.4-ha (1-ac) parking lot at the Edison Environmental Center in Edison, NJ, that incorporated three different permeable pavement types - permeable interlocking concrete pavers (PICP), pervious concrete (PC), and porous asphalt (PA). The driving lanes...

  9. Specific absorption rate dependence on temperature in magnetic field hyperthermia measured by dynamic hysteresis losses (ac magnetometry).

    PubMed

    Garaio, Eneko; Sandre, Olivier; Collantes, Juan-Mari; Garcia, Jose Angel; Mornet, Stéphane; Plazaola, Fernando

    2015-01-09

    Magnetic nanoparticles (NPs) are intensively studied for their potential use for magnetic hyperthermia, a treatment that has passed a phase II clinical trial against severe brain cancer (glioblastoma) at the end of 2011. Their heating power, characterized by the 'specific absorption rate (SAR)', is often considered temperature independent in the literature, mainly because of the difficulties that arise from the measurement methodology. Using a dynamic magnetometer presented in a recent paper, we measure here the thermal dependence of SAR for superparamagnetic iron oxide (maghemite) NPs of four different size-ranges corresponding to mean diameters around 12 nm, 14 nm, 15 nm and 16 nm. The article reports a parametrical study extending from 10 to 60 °C in temperature, from 75 to 1031 kHz in frequency, and from 2 to 24 kA m(-1) in magnetic field strength. It was observed that SAR values of smaller NPs decrease with temperature whereas for the larger sample (16 nm) SAR values increase with temperature. The measured variation of SAR with temperature is frequency dependent. This behaviour is fully explained within the scope of linear response theory based on Néel and Brown relaxation processes, using independent magnetic measurements of the specific magnetization and the magnetic anisotropy constant. A good quantitative agreement between experimental values and theoretical values is confirmed in a tri-dimensional space that uses as coordinates the field strength, the frequency and the temperature.

  10. Specific absorption rate dependence on temperature in magnetic field hyperthermia measured by dynamic hysteresis losses (ac magnetometry)

    NASA Astrophysics Data System (ADS)

    Garaio, Eneko; Sandre, Olivier; Collantes, Juan-Mari; Garcia, Jose Angel; Mornet, Stéphane; Plazaola, Fernando

    2015-01-01

    Magnetic nanoparticles (NPs) are intensively studied for their potential use for magnetic hyperthermia, a treatment that has passed a phase II clinical trial against severe brain cancer (glioblastoma) at the end of 2011. Their heating power, characterized by the ‘specific absorption rate (SAR)’, is often considered temperature independent in the literature, mainly because of the difficulties that arise from the measurement methodology. Using a dynamic magnetometer presented in a recent paper, we measure here the thermal dependence of SAR for superparamagnetic iron oxide (maghemite) NPs of four different size-ranges corresponding to mean diameters around 12 nm, 14 nm, 15 nm and 16 nm. The article reports a parametrical study extending from 10 to 60 {}^\\circ C in temperature, from 75 to 1031 kHz in frequency, and from 2 to 24 kA m-1 in magnetic field strength. It was observed that SAR values of smaller NPs decrease with temperature whereas for the larger sample (16 nm) SAR values increase with temperature. The measured variation of SAR with temperature is frequency dependent. This behaviour is fully explained within the scope of linear response theory based on Néel and Brown relaxation processes, using independent magnetic measurements of the specific magnetization and the magnetic anisotropy constant. A good quantitative agreement between experimental values and theoretical values is confirmed in a tri-dimensional space that uses as coordinates the field strength, the frequency and the temperature.

  11. Amorphous force transducers in ac applications

    NASA Astrophysics Data System (ADS)

    Meydan, T.; Overshott, K. J.

    1982-11-01

    The high stress sensitivity and high yield stress properties of amorphous ribbon materials make them suitable for magnetic sensors and tranducer applications. Recently the authors have shown that ac systems eliminate the offset voltage and drift problems of the previously published dc systems. Further investigations proved that these transducers could be operated with a linear characteristic up to 1000 g in multiwrap toroidal configurations. The cause of the transducing behavior of the materials was proved to be variation of permeability with stress. It was previously suggested that the optimum operating frequency of the ac transducers is dependent on the physical configuration of the core. Further investigations have shown that the optimum operating frequency is linearly dependent on the amplitude of the input signal to the transducer. Double-core systems have been previously described in the literature where one core acts as a dummy core and the force is applied to the active core. The disadvantage of the double-core system is that aging of the active core changes the performance of the transducer by as much as 10%. A new system will be presented which uses an accurate analog memory to reduce the ageing effect to a fraction of one percent.

  12. Kinetic analysis of spin current contribution to spectrum of electromagnetic waves in spin-1/2 plasma. I. Dielectric permeability tensor for magnetized plasmas

    NASA Astrophysics Data System (ADS)

    Andreev, Pavel A.

    2017-02-01

    The dielectric permeability tensor for spin polarized plasmas is derived in terms of the spin-1/2 quantum kinetic model in six-dimensional phase space. Expressions for the distribution function and spin distribution function are derived in linear approximations on the path of dielectric permeability tensor derivation. The dielectric permeability tensor is derived for the spin-polarized degenerate electron gas. It is also discussed at the finite temperature regime, where the equilibrium distribution function is presented by the spin-polarized Fermi-Dirac distribution. Consideration of the spin-polarized equilibrium states opens possibilities for the kinetic modeling of the thermal spin current contribution in the plasma dynamics.

  13. ELECTRICAL AND ELECTRONIC INDUSTRIAL CONTROL. A-C CONVENTIONAL MAGNETIC MOTOR CONTROL, PART II, UNIT 6, ASSIGNMENTS.

    ERIC Educational Resources Information Center

    SUTTON, MACK C.

    THIS STUDY GUIDE IS FOR INDIVIDUAL STUDENT USE IN STUDYING ALTERNATING CURRENT CONVENTIONAL MAGNETIC MOTOR CONTROL IN ELECTRICAL-ELECTRONIC PROGRAMS. IT WAS DEVELOPED BY AN INSTRUCTIONAL MATERIALS SPECIALIST AND ADVISERS. EACH OF THE 10 ASSIGNMENT SHEETS PROVIDES THE LESSON SUBJECT, PURPOSE, INTRODUCTORY INFORMATION, STUDY REFERENCES,…

  14. ELECTRICAL AND ELECTRONIC INDUSTRIAL CONTROL. A-C CONVENTIONAL MAGNETIC MOTOR CONTROL, PART I, UNIT 5, INSTRUCTOR'S GUIDE.

    ERIC Educational Resources Information Center

    SUTTON, MACK C.

    THIS GUIDE IS FOR TEACHER USE IN DIRECTING INDIVIDUAL STUDY OF ALTERNATING CURRENT CONVENTIONAL MAGNETIC MOTOR CONTROL IN ELECTRICAL-ELECTRONIC PROGRAMS. IT WAS DEVELOPED BY AN INSTRUCTIONAL MATERIALS SPECIALIST AND ADVISERS. EACH OF THE 10 INSTRUCTOR'S SHEETS GIVES THE LESSON SUBJECT, PURPOSE, INTRODUCTORY INFORMATION, REFERENCES, AND…

  15. ELECTRICAL AND ELECTRONIC INDUSTRIAL CONTROL. A-C CONVENTIONAL MAGNETIC MOTOR CONTROL, PART I, UNIT 5, ASSIGNMENTS.

    ERIC Educational Resources Information Center

    SUTTON, MACK C.

    THIS GUIDE IS FOR INDIVIDUAL STUDENT USE IN STUDYING ALTERNATING CURRENT CONVENTIONAL MAGNETIC MOTOR CONTROL IN ELECTRICAL-ELECTRONIC PROGRAMS. IT WAS DEVELOPED BY AN INSTRUCTIONAL MATERIALS SPECIALIST AND ADVISERS. EACH OF THE 10 ASSIGNMENT SHEETS PROVIDES THE LESSON SUBJECT, PURPOSE, INTRODUCTORY INFORMATION, STUDY REFERENCES, SUPPLEMENTARY…

  16. ELECTRICAL AND ELECTRONIC INDUSTRIAL CONTROL. A-C CONVENTIONAL MAGNETIC MOTOR CONTROL, PART II, UNIT 6, INSTRUCTOR'S GUIDE.

    ERIC Educational Resources Information Center

    SUTTON, MACK C.

    THIS GUIDE IS FOR TEACHER USE IN DIRECTING INDIVIDUAL STUDY OF ALTERNATING CURRENT CONVENTIONAL MAGNETIC MOTOR CONTROL IN ELECTRICAL-ELECTRONIC PROGRAMS. IT WAS DEVELOPED BY AN INSTRUCTIONAL MATERIALS SPECIALIST AND ADVISERS. EACH OF THE 10 INSTRUCTOR'S SHEETS GIVES THE LESSON SUBJECT, PURPOSE, INTRODUCTORY INFORMATION, REFERENCES, SUPPLEMENTARY…

  17. A Pilot Study Measuring the Distribution and Permeability of a Vaginal HIV Microbicide Gel Vehicle Using Magnetic Resonance Imaging, Single Photon Emission Computed Tomography/Computed Tomography, and a Radiolabeled Small Molecule

    PubMed Central

    Schwartz, Jill L.; Friend, David R.; Coleman, Jenell S.; Hendrix, Craig W.

    2015-01-01

    Abstract Vaginal microbicide gels containing tenofovir have proven effective in HIV prevention, offering the advantage of reduced systemic toxicity. We studied the vaginal distribution and effect on mucosal permeability of a gel vehicle. Six premenopausal women were enrolled. In Phase 1, a spreading gel containing 99mtechnetium-DTPA (99mTc) radiolabel and gadolinium contrast for magnetic resonance imaging (MRI) was dosed intravaginally. MRI was obtained at 0.5, 4, and 24 h, and single photon emission computed tomography with conventional computed tomography (SPECT/CT) at 1.5, 5, and 25 h postdosing. Pads and tissues were measured for activity to determine gel loss. In Phase 2, nonoxynol-9 (N-9), containing 99mTc-DTPA, was dosed as a permeability control; permeability was measured in blood and urine for both phases. SPECT/CT showed the distribution of spreading gel throughout the vagina with the highest concentration of radiosignal in the fornices and ectocervix; signal intensity diminished over 25 h. MRI showed the greatest signal accumulation in the fornices, most notably 1–4 h postdosing. The median (interquartile range) isotope signal loss from the vagina through 6 h was 29.1% (15.8–39.9%). Mucosal permeability to 99mTc-DTPA following spreading gel was negligible, in contrast to N-9, with detectable radiosignal in plasma, peaking at 8 h (5–12). Following spreading gel dosing, 0.004% (0.001–2.04%) of the radiosignal accumulated in urine over 12 h compared to 8.31% (7.07–11.01%) with N-9, (p=0.043). Spreading gel distributed variably throughout the vagina, persisting for 24 h, with signal concentrating in the fornices and ectocervix. The spreading gel had no significant effect on vaginal mucosal permeability. PMID:26077739

  18. High-frequency permeability spectra of FeCoSiN/Al{sub 2}O{sub 3} laminated films: Tuning of damping by magnetic couplings dependent on the thickness of each ferromagnetic layer

    SciTech Connect

    Xu Feng; Zhang Xiaoyu; Nguyen Nguyen Phuoc; Ma Yungui; Ong, C. K.

    2009-02-15

    In this work, we investigate the high-frequency permeability spectra of as-sputtered FeCoSiN/Al{sub 2}O{sub 3} laminated films, and discuss their dependence on the thickness of each FeCoSiN layer, based on the phenomenological Landau-Lifshitz-Gilbert equation. The damping factor and coercivity show their minima with lamination, deviating from the expectation based on the grain size confinement effect. Such dependences on the layer thickness indicate the influence of magnetic coupling. The decreases in the damping factor and the coercivities with lamination can be partially attributed to the decrease in the magnetostatic coupling induced by ripple structures. The enhanced damping and enlarged coercivity values obtained with further lamination are ascribed to the enhanced Neel couplings. The dependences show that the lamination can be effective in tuning the magnetization dynamics by changing the magnetic couplings.

  19. High frequency AC response, DC resistivity and magnetic studies of holmium substituted Ni-ferrite: A novel electromagnetic material

    NASA Astrophysics Data System (ADS)

    Pervaiz, Erum; Gul, I. H.

    2014-01-01

    Nanoparticles of holmium substituted nickel ferrites (NiHoxFe2-xO4) with x ranging from 0.0 to 0.15 have been prepared by the sol-gel auto-combustion method. Structural and morphology studies have been performed by X-ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). XRD patterns revealed the formation of pure spinel phase ferrites without any impurity phase. Lattice parameter increases along with a decrease in crystallite size with increasing the concentration of Ho3+ in the parent nickel ferrite due to large ionic radius of Ho3+ (0.901 Å) as compared to Fe3+ (0.67 Å). SEM shows the spherical, uniformly distributed homogenous nanoparticles grown by controlled reaction parameters of the sol-gel method. Complex permittivity (ɛ*) and complex electric modulus (M*) have been studied for the present nanoferrites in the frequency ranges of 1 MHz-1 GHz. Frequency dependent dielectric parameters (relative permittivity (ɛ'), dielectric loss (ɛ″), dielectric loss tangent (tan δ)) decreases due to holmium substitution in nickel ferrites, showing the electrical conduction is decreasing in the nickel holmium ferrites with increase in the concentration of holmium. Complex modulus plots shows the poorly resolved semi circles and relaxation of nanoferrite is studied in the high frequency region. Also the relaxation time increases due to increase in x (0.0-0.15). DC electrical resistivity increases (107 Ω-cm-1010 Ω-cm) due to holmium ions substitution in nickel ferrites. Magnetic behavior was also characterized using a Vibrating Sample Magnetometer (VSM) under an applied magnetic field of 10 kOe and shows that magnetization decreases with increase in composition of holmium in nickel ferrites. High frequency behavior, low losses and very high DC electrical resistivity made the material a novel one for electromagnetic devices.

  20. AC loss measurements of twisted and untwisted BSCCO multifilamentary tapes

    NASA Astrophysics Data System (ADS)

    Jiang, Zhenan; Amemiya, Naoyuki; Nishioka, Takamasa; Oh, Sang-Soo

    2005-01-01

    AC losses in twisted and untwisted BSCCO multifilamentary superconducting tapes with Ag matrix developed in DAPAS program were measured by an electrical method. Magnetization and transport losses were measured by a pick-up coil and by a voltage taps. Total AC loss during simultaneous application of AC transport current and an AC transverse magnetic field was given by the sum of the magnetization and transport losses measured during this simultaneous application. The magnetization loss without transport current of untwisted and twisted tapes was measured first to evaluate the effect of twisting to decouple filaments. Then, the total AC loss of the twisted tape was measured in transverse magnetic fields with various amplitudes and orientations, while the amplitude of the transport current was fixed. The measured total AC loss in a parallel transverse magnetic field was compared with some theoretical models to study the detailed characteristics of the measured total AC loss of the sample.

  1. Vascular permeability in cerebral cavernous malformations.

    PubMed

    Mikati, Abdul G; Khanna, Omaditya; Zhang, Lingjiao; Girard, Romuald; Shenkar, Robert; Guo, Xiaodong; Shah, Akash; Larsson, Henrik B W; Tan, Huan; Li, Luying; Wishnoff, Matthew S; Shi, Changbin; Christoforidis, Gregory A; Awad, Issam A

    2015-10-01

    Patients with the familial form of cerebral cavernous malformations (CCMs) are haploinsufficient for the CCM1, CCM2, or CCM3 gene. Loss of corresponding CCM proteins increases RhoA kinase-mediated endothelial permeability in vitro, and in mouse brains in vivo. A prospective case-controlled observational study investigated whether the brains of human subjects with familial CCM show vascular hyperpermeability by dynamic contrast-enhanced quantitative perfusion magnetic resonance imaging, in comparison with CCM cases without familial disease, and whether lesional or brain vascular permeability correlates with CCM disease activity. Permeability in white matter far (WMF) from lesions was significantly greater in familial than in sporadic cases, but was similar in CCM lesions. Permeability in WMF increased with age in sporadic patients, but not in familial cases. Patients with more aggressive familial CCM disease had greater WMF permeability compared to those with milder disease phenotype, but similar lesion permeability. Subjects receiving statin medications for routine cardiovascular indications had a trend of lower WMF, but not lesion, permeability. This is the first demonstration of brain vascular hyperpermeability in humans with an autosomal dominant disease, as predicted mechanistically. Brain permeability, more than lesion permeability, may serve as a biomarker of CCM disease activity, and help calibrate potential drug therapy.

  2. Vascular permeability in cerebral cavernous malformations

    PubMed Central

    Mikati, Abdul G; Khanna, Omaditya; Zhang, Lingjiao; Girard, Romuald; Shenkar, Robert; Guo, Xiaodong; Shah, Akash; Larsson, Henrik BW; Tan, Huan; Li, Luying; Wishnoff, Matthew S; Shi, Changbin; Christoforidis, Gregory A; Awad, Issam A

    2015-01-01

    Patients with the familial form of cerebral cavernous malformations (CCMs) are haploinsufficient for the CCM1, CCM2, or CCM3 gene. Loss of corresponding CCM proteins increases RhoA kinase-mediated endothelial permeability in vitro, and in mouse brains in vivo. A prospective case-controlled observational study investigated whether the brains of human subjects with familial CCM show vascular hyperpermeability by dynamic contrast-enhanced quantitative perfusion magnetic resonance imaging, in comparison with CCM cases without familial disease, and whether lesional or brain vascular permeability correlates with CCM disease activity. Permeability in white matter far (WMF) from lesions was significantly greater in familial than in sporadic cases, but was similar in CCM lesions. Permeability in WMF increased with age in sporadic patients, but not in familial cases. Patients with more aggressive familial CCM disease had greater WMF permeability compared to those with milder disease phenotype, but similar lesion permeability. Subjects receiving statin medications for routine cardiovascular indications had a trend of lower WMF, but not lesion, permeability. This is the first demonstration of brain vascular hyperpermeability in humans with an autosomal dominant disease, as predicted mechanistically. Brain permeability, more than lesion permeability, may serve as a biomarker of CCM disease activity, and help calibrate potential drug therapy. PMID:25966944

  3. Engineered Trehalose Permeable to Mammalian Cells.

    PubMed

    Abazari, Alireza; Meimetis, Labros G; Budin, Ghyslain; Bale, Shyam Sundhar; Weissleder, Ralph; Toner, Mehmet

    2015-01-01

    Trehalose is a naturally occurring disaccharide which is associated with extraordinary stress-tolerance capacity in certain species of unicellular and multicellular organisms. In mammalian cells, presence of intra- and extracellular trehalose has been shown to confer improved tolerance against freezing and desiccation. Since mammalian cells do not synthesize nor import trehalose, the development of novel methods for efficient intracellular delivery of trehalose has been an ongoing investigation. Herein, we studied the membrane permeability of engineered lipophilic derivatives of trehalose. Trehalose conjugated with 6 acetyl groups (trehalose hexaacetate or 6-O-Ac-Tre) demonstrated superior permeability in rat hepatocytes compared with regular trehalose, trehalose diacetate (2-O-Ac-Tre) and trehalose tetraacetate (4-O-Ac-Tre). Once in the cell, intracellular esterases hydrolyzed the 6-O-Ac-Tre molecules, releasing free trehalose into the cytoplasm. The total concentration of intracellular trehalose (plus acetylated variants) reached as high as 10 fold the extracellular concentration of 6-O-Ac-Tre, attaining concentrations suitable for applications in biopreservation. To describe this accumulation phenomenon, a diffusion-reaction model was proposed and the permeability and reaction kinetics of 6-O-Ac-Tre were determined by fitting to experimental data. Further studies suggested that the impact of the loading and the presence of intracellular trehalose on cellular viability and function were negligible. Engineering of trehalose chemical structure rather than manipulating the cell, is an innocuous, cell-friendly method for trehalose delivery, with demonstrated potential for trehalose loading in different types of cells and cell lines, and can facilitate the wide-spread application of trehalose as an intracellular protective agent in biopreservation studies.

  4. Characterizing and calibrating a large Helmholtz coil at low ac magnetic field levels with peak magnitudes below the earth's magnetic field

    NASA Astrophysics Data System (ADS)

    Schill, Robert A.; Hoff, Karin

    2001-06-01

    Characterizing and calibrating a low impedance large Helmholtz coil generating 60 Hz magnetic fields with amplitudes well below the earth's magnetic field is difficult and imprecise when coil shielding is not available and noise is an issue. Parameters influencing the calibration process such as temperature and coil impedance need to be figured in the calibration process. A simple and reliable calibration technique is developed and used to measure low amplitude fields over a spatial grid using a standard Hall effect probe gaussmeter. These low amplitude fields are typically hard or impossible to detect in the presence of background fields when using the gaussmeter in the conventional manner. Standard deviations of two milligauss and less have been achieved over a spatial grid in a uniform field region. Theoretical and measured fields are compared yielding reasonable agreement for a large coil system designed and built for bioelectromagnetic experiments at the University of Nevada at Las Vegas using simple tools. Theoretical results need to be compared with and adjusted in accord with measurements taken over a large parameter space within the design constraints of the coil. Magnetic field measurements made over a four year period are shown to be consistent. Characterizing and calibrating large Helmholtz coils can be performed with rulers, levels, plumb lines, and inexpensive gaussmeters.

  5. Structural, magnetic, DC-AC electrical conductivities and thermo electric studies of MgCuZn Ferrites for microinductor applications.

    PubMed

    Varalaxmi, N; Sivakumar, K V

    2013-01-01

    Multilayer chip inductors (MLCIs) have been rapidly developed for electromagnetic applications. NiCuZn ferrites are the most preferred ferrite materials to produce MLCIs. MgCuZn ferrites have similar properties to those of NiCuZn ferrites. MgCuZn ferrites owing to their superior properties like low magnetostriction, environmental stability, low stress sensitivity, high resistivity and low cost can replace NiCuZn ferrites, which have a wide range of electronic applications. In view of this, a series of polycrystalline MgCuZn ferrites with generic formula MgxCu0.5Zn0.5-xFe2O4 (X=0.0 0.1, 0.2, 0.3, 0.4 and 0.5) are successfully synthesized by conventional double sintering technique. The samples were then characterized by the X-ray diffraction patterns (XRD) microstructural studies and the grain size was estimated using SEM micrographs. The sintered ferrites have been investigated in their magnetic, electrical and thermoelectric effect studies, which were carried out in the temperature range from 30 °C to 490 °C. The investigated ferrites are found to exhibit excellent properties that are suitable for the core materials in multilayer chip inductors, and the results are discussed.

  6. Permeability of Clay Concretes

    NASA Astrophysics Data System (ADS)

    Solomon, F.; Ekolu, S. O.

    2015-11-01

    This paper presents an investigation on the effect of clay addition on water permeability and air permeability of concretes. Clay concrete mixes consisted of 0 to 40% clay content incorporated as cement replacement. Flow methods using triaxial cells and air permeameters were used for measuring the injected water and air flows under pressure. It was found that the higher the clay content in the mixture, the greater the permeability. At higher water-cement ratios (w/c), the paste matrix is less dense and easily allows water to ingress into concrete. But at high clay contents of 30 to 40% clay, the variation in permeability was significantly diminished among different concrete mixtures. It was confirmed that air permeability results were higher than the corresponding water permeability values when all permeability coefficients were converted to intrinsic permeability values.

  7. EPA Permeable Surface Research

    EPA Science Inventory

    EPA recognizes permeable surfaces as an effective post-construction infiltration-based Best Management Practice to mitigate the adverse effects of stormwater runoff. The professional user community conceptually embraces permeable surfaces as a tool for making runoff more closely...

  8. A superconducting magnetic gear

    NASA Astrophysics Data System (ADS)

    Campbell, A. M.

    2016-05-01

    A comparison is made between a magnetic gear using permanent magnets and superconductors. The objective is to see if there are any fundamental reasons why superconducting magnets should not provide higher power densities than permanent magnets. The gear is based on the variable permeability design of Attilah and Howe (2001 IEEE Trans. Magn. 37 2844-46) in which a ring of permanent magnets surrounding a ring of permeable pole pieces with a different spacing gives an internal field component at the beat frequency. Superconductors can provide much larger fields and forces but will saturate the pole pieces. However the gear mechanism still operates, but in a different way. The magnetisation of the pole pieces is now constant but rotates with angle at the beat frequency. The result is a cylindrical Halbach array which produces an internal field with the same symmetry as in the linear regime, but has an analytic solution. In this paper a typical gear system is analysed with finite elements using FlexPDE. It is shown that the gear can work well into the saturation regime and that the Halbach array gives a good approximation to the results. Replacing the permanent magnets with superconducting tapes can give large increases in torque density, and for something like a wind turbine a combined gear and generator is possible. However there are major practical problems. Perhaps the most fundamental is the large high frequency field which is inevitably present and which will cause AC losses. Also large magnetic fields are required, with all the practical problems of high field superconducting magnets in rotating machines. Nevertheless there are ways of mitigating these difficulties and it seems worthwhile to explore the possibilities of this technology further.

  9. Film Permeability Determination Using Static Permeability Cells

    EPA Pesticide Factsheets

    The permeability of tarps to soil fumigant pesticides varies depending on the active ingredient chemical: dimethyl disulfide (DMDS), methyl bromide, chloropicrin, or other. The diffusion rate can be represented by the mass transfer coefficient (MTC).

  10. RHIC spin flipper AC dipole controller

    SciTech Connect

    Oddo, P.; Bai, M.; Dawson, C.; Gassner, D.; Harvey, M.; Hayes, T.; Mernick, K.; Minty, M.; Roser, T.; Severino, F.; Smith, K.

    2011-03-28

    The RHIC Spin Flipper's five high-Q AC dipoles which are driven by a swept frequency waveform require precise control of phase and amplitude during the sweep. This control is achieved using FPGA based feedback controllers. Multiple feedback loops are used to and dynamically tune the magnets. The current implementation and results will be presented. Work on a new spin flipper for RHIC (Relativistic Heavy Ion Collider) incorporating multiple dynamically tuned high-Q AC-dipoles has been developed for RHIC spin-physics experiments. A spin flipper is needed to cancel systematic errors by reversing the spin direction of the two colliding beams multiple times during a store. The spin flipper system consists of four DC-dipole magnets (spin rotators) and five AC-dipole magnets. Multiple AC-dipoles are needed to localize the driven coherent betatron oscillation inside the spin flipper. Operationally the AC-dipoles form two swept frequency bumps that minimize the effect of the AC-dipole dipoles outside of the spin flipper. Both AC bumps operate at the same frequency, but are phase shifted from each other. The AC-dipoles therefore require precise control over amplitude and phase making the implementation of the AC-dipole controller the central challenge.

  11. Investigation of the permeability tensor of electrical steel sheet

    SciTech Connect

    Birkfeld, M.

    1998-09-01

    The permeability tensor is a mathematical model for the description of the electro-magnetic behavior of electrical silicon iron steel sheet under two-dimensional magnetizing conditions. In this paper, an interpretation of the properties of this tensor is given, the investigation of the tensor elements from measurements under two-dimensional magnetizing conditions is described, and some examples of measurements and the corresponding permeability tensor elements are indicated.

  12. Negative permeability from random particle composites

    NASA Astrophysics Data System (ADS)

    Hussain, Shahid

    2017-04-01

    Artificial media, such as those composed of periodically-spaced wires for negative permittivity and split ring resonators for negative permeability have been extensively investigated for negative refractive index (NRI) applications (Smith et al., 2004; Pendry et al., 1999) [1,2]. This paper presents an alternative method for producing negative permeability: granular (or particulate) composites incorporating magnetic fillers. Artificial media, such as split-ring resonators, are designed to produce a magnetic resonance feature, which results in negative permeability over a narrow frequency range about the resonance frequency. The position of the feature is dependent upon the size of the inclusion. The material in this case is anisotropic, such that the feature is only observable when the materials are orientated in a specific direction relative to the applied field. A similar resonance can be generated in magnetic granular (particulate) materials: ferromagnetic resonance from the natural spin resonance of particles. Although the theoretical resonance profiles in granular composites shows the permeability dipping to negative values, this is rarely observed experimentally due to resonance damping effects. Results are presented for iron in spherical form and in flake form, dispersed in insulating host matrices. The two particle shapes show different permeability performance, with the magnetic flakes producing a negative contribution. This is attributed to the stronger coupling with the magnetic field resulting from the high aspect ratio of the flakes. The accompanying ferromagnetic resonance is strong enough to overcome the effects of damping and produce negative permeability. The size of random particle composites is not dictated by the wavelength of the applied field, so the materials are potentially much thinner than other, more traditional artificial composites at microwave frequencies.

  13. HP-41 Calculates Dykstra-Parsons permeability

    SciTech Connect

    Bixler, B.

    1983-07-01

    A new program for the HP-41 programmable calculator has been written which will calculate the often used Dykstra-Parsons permeability variation factor, V. No longer must numerous individual permeability values be plotted on log probability paper as a first step in determining V. Input is simply these same permeability values selected at equal spacing along the interval in question. For most core analysis this spacing will be 1 ft. This program is labeled ''KVAR'' (for permeability variation) and is listed here, along with its bar code for those with optical wands. It requires only nine registers for program storage (since it uses HP built-in statistical functions) and eight registers for data storage. Also, it can be stored on one track of the standard two-track magnetic card. Data entry is terminated by entering ''O''. Lastly, it will run with or without a printer.

  14. Permeability of Dentine

    PubMed Central

    Ghazali, Farid Bin Che

    2003-01-01

    This is an update on the present integrated knowledge regarding dentine permeability that assumed a role in dentine sensitivity and contribute clinically to the effective bonding properties of restorative dental materials. This paper will attempt to refer to in vivo and in vitro studies of dentine permeability and the various interrelated factors governing it. PMID:23365497

  15. Investigation of magnetic spin glass property in La{sub 0.5}Bi{sub 0.5}MnO{sub 3} sample using non-linear AC susceptibility measurements

    SciTech Connect

    Kumar, Punith V. Manju, M. R. Dayal, Vijaylakshmi

    2014-04-24

    We present a comprehensive study on origin of Spin Glass (SG) property in polycrystalline La{sub 0.5}Bi{sub 0.5}MnO{sub 3} perovskite oxide using linear and higher order ac susceptibility (χ) measurements. The third order harmonic susceptibility (χ{sub 3}) vs. temperature (K) with varying magnetic fields from 0.95 to 9.45 Oe and the divergence in their χ{sub 3} (max) allows us to infer the SG behavior occurring in the sample possibly due to co-operative freezing of the spins.

  16. Magnetic measurements at Lawrence Berkeley Laboratory

    NASA Astrophysics Data System (ADS)

    Green, M. I.; Barale, P.; Callapp, L.; Case-Fortier, M.; Lerner, D.; Nelson, D.; Schermer, R.; Skipper, G.; Vandyke, D.; Cork, C.

    1991-08-01

    Recent magnetic measurement activities at LBL have been concentrated in two separate areas, electro-magnets and permanent magnets for the Advanced Light Source (ALS), and superconducting magnets for the Superconducting Super Collider Laboratory (SSCL). A survey of the many different measurement systems is presented. These include: AC magnetic measurements of an ALS booster dipole engineering model magnet, dipole moment measurements of permanent magnet blocks for ALS wigglers and undulators, permeability measurements of samples destined for wiggler and undulator poles, harmonic error analysis of SSC one meter model dipoles and quadrupoles and five meter long SSC prototype quadrupoles, harmonic error analysis of ALS dipoles, quadrupoles, and sextupoles, precision Hall probe mapping of ALS storage ring combined function magnets, and the design of the ALS insertion device magnets mapping system. We also describe a new UNIX based data acquisition system that is being developed for the SSC. Probes used for magnetic measurements include Helmholtz coils, integral coils, point coils, and bucking harmonic analysis coils, several different types of Hall probes, and nuclear magnetic resonance magnetometers. Both analog and digital integrators are used with the coils. Some problems that occurred and their rectification is described. The mechanisms used include rotating systems with optical encoders, X-Y mapping systems with optical encoders and a laser position measuring device.

  17. Permeability of porour rhyolite

    NASA Astrophysics Data System (ADS)

    Cashman, K.; Rust, A.; Wright, H.; Roberge, J.

    2003-04-01

    The development of permeability in bubble-bearing magmas determines the efficiency of volatile escape during their ascent through volcanic conduits, which, in turn, controls their explosive potential. As permeability requires bubble connectivity, relationships between permeability and porosity in silicic magmas must be controlled by the formation, growth, deformation and coalescence of their constituent bubbles. Although permeability data on porous volcanic pyroclasts are limited, the database can be greatly extended by including data for ceramic and metallic foams1. Several studies indicate that a single number does not adequately describe the permeability of a foam because inertial effects, which predominate at high flow rates, cause deviations from Darcy's law. These studies suggest that permeability is best modeled using the Forschheimer equation to determine both the Darcy permeability (k1) and the non-Darcian (k2) permeability. Importantly, at the high porosities of ceramic foams (75-95%), both k1 and k2 are strongly dependent on pore size and geometry, suggesting that measurement of these parameters provides important information on foam structure. We determined both the connected porosity (by He-pycnometry) and the permeability (k1 and k2) of rhyolitic samples having a wide range in porosity (22-85%) and vesicle textures. In general, these data support previous observations of a power law relationship between connected porosity and Darcy permeability2. In detail, variations in k1 increase at higher porosities. Similarly, k2 generally increases in both mean and standard deviation with increasing porosity. Measurements made on three mutually perpendicular cores from individual pumice clasts suggest that some of the variability can be explained by anisotropy in the vesicle structure. By comparison with ceramic foams, we suggest that the remaining variability results from differences either in average vesicle size or, more likely, in the size of apertures

  18. Permeability of edible coatings.

    PubMed

    Mishra, B; Khatkar, B S; Garg, M K; Wilson, L A

    2010-01-01

    The permeabilities of water vapour, O2 and CO2 were determined for 18 coating formulations. Water vapour transmission rate ranged from 98.8 g/m(2).day (6% beeswax) to 758.0 g/m(2).day (1.5% carboxymethyl cellulose with glycerol). O2 permeability at 14 ± 1°C and 55 ± 5% RH ranged from 1.50 to 7.95 cm(3)cm cm(-2)s(-1)Pa(-1), with CO2 permeability 2 to 6 times as high. Permeability to noncondensable gases (O2 and CO2) was higher for hydrophobic (peanut oil followed by beeswax) coatings as compared to hydrophilic (whey protein concentrate and carboxymethyl cellulose).

  19. Seismic waves increase permeability.

    PubMed

    Elkhoury, Jean E; Brodsky, Emily E; Agnew, Duncan C

    2006-06-29

    Earthquakes have been observed to affect hydrological systems in a variety of ways--water well levels can change dramatically, streams can become fuller and spring discharges can increase at the time of earthquakes. Distant earthquakes may even increase the permeability in faults. Most of these hydrological observations can be explained by some form of permeability increase. Here we use the response of water well levels to solid Earth tides to measure permeability over a 20-year period. At the time of each of seven earthquakes in Southern California, we observe transient changes of up to 24 degrees in the phase of the water level response to the dilatational volumetric strain of the semidiurnal tidal components of wells at the Piñon Flat Observatory in Southern California. After the earthquakes, the phase gradually returns to the background value at a rate of less than 0.1 degrees per day. We use a model of axisymmetric flow driven by an imposed head oscillation through a single, laterally extensive, confined, homogeneous and isotropic aquifer to relate the phase response to aquifer properties. We interpret the changes in phase response as due to changes in permeability. At the time of the earthquakes, the permeability at the site increases by a factor as high as three. The permeability increase depends roughly linearly on the amplitude of seismic-wave peak ground velocity in the range of 0.21-2.1 cm s(-1). Such permeability increases are of interest to hydrologists and oil reservoir engineers as they affect fluid flow and might determine long-term evolution of hydrological and oil-bearing systems. They may also be interesting to seismologists, as the resulting pore pressure changes can affect earthquakes by changing normal stresses on faults.

  20. Ac irreversibility line of bismuth-based high temperature superconductors

    SciTech Connect

    Mehdaoui, A.; Beille, J.; Berling, D.; Loegel, B.; Noudem, J.G.; Tournier, R.

    1997-09-01

    We discuss the magnetic properties of lead doped Bi-2223 bulk samples obtained through combined magnetic melt texturing and hot pressing (MMTHP). The ac complex susceptibility measurements are achieved over a broad ac field range (1 Oe{lt}h{sub ac}{lt}100 Oe) and show highly anisotropic properties. The intergranular coupling is improved in the direction perpendicular to the applied stress and magnetic field direction, and an intragranular loss peak is observed for the first time. A comparison is made with other bismuth-based compounds and it is shown that the MMTHP process shifts the ac irreversibility line (ac IL) toward higher fields. It is also shown that all the ac IL{close_quote}s for quasi 2D bismuth-based compounds show a nearly quadratic temperature dependence and deviate therefore strongly from the linear behavior observed in quasi 3D compounds and expected from a critical state model.{copyright} {ital 1997 Materials Research Society.}

  1. YBCO Coated Conductors with Reduced AC Losses

    DTIC Science & Technology

    2008-01-30

    application such as turbo- generators and gyrotron magnets . The major reason is the enhanced in-field performance at 50-65 K and the proven...transformers, current limiters and the stators of rotating equipment. Low AC-loss in 2G HTS requires wire components with low magnetism , and an YBCO...layer with low transport and low hysteretic losses in an alternating magnetic field. The latter loss type requires a suitable filamentization technique

  2. A Multi-Level Grid Interactive Bi-directional AC/DC-DC/AC Converter and a Hybrid Battery/Ultra-capacitor Energy Storage System with Integrated Magnetics for Plug-in Hybrid Electric Vehicles

    SciTech Connect

    Onar, Omer C

    2011-01-01

    This study presents a bi-directional multi-level power electronic interface for the grid interactions of plug-in hybrid electric vehicles (PHEVs) as well as a novel bi-directional power electronic converter for the combined operation of battery/ultracapacitor hybrid energy storage systems (ESS). The grid interface converter enables beneficial vehicle-to-grid (V2G) interactions in a high power quality and grid friendly manner; i.e, the grid interface converter ensures that all power delivered to/from grid has unity power factor and almost zero current harmonics. The power electronic converter that provides the combined operation of battery/ultra-capacitor system reduces the size and cost of the conventional ESS hybridization topologies while reducing the stress on the battery, prolonging the battery lifetime, and increasing the overall vehicle performance and efficiency. The combination of hybrid ESS is provided through an integrated magnetic structure that reduces the size and cost of the inductors of the ESS converters. Simulation and experimental results are included as prove of the concept presenting the different operation modes of the proposed converters.

  3. Experimental study of loss mechanisms of AgAu/PbBi-2223 tapes with twisted filaments under perpendicular AC magnetic fields at power frequencies

    NASA Astrophysics Data System (ADS)

    Martínez, E.; Yang, Y.; Beduz, C.; Huang, Y. B.

    2000-05-01

    AC losses under perpendicular AC fields have been measured at 77 K and power frequencies for multifilamentary AgAu (10 wt.%)/Bi-2223 tapes with filaments twisted at different pitches. Using simultaneous measurements of the first and higher harmonics of the voltage induced in the pick-up coil, the main loss contributions (superconductor and coupling current losses) have been obtained separately. At power frequencies, twisting produces the desired uncoupling of the filaments at fields lower than the coupling field, which has also been determined experimentally. In the uncoupled-filament regime, the superconductor losses are reduced strongly with respect to the untwisted tapes. The reduction of the total loss with twisting is also observed. However, due to the important contribution of the coupling current losses for this field orientation, a very small pitch (<5 mm) is necessary for a considerably lower loss than that of untwisted tapes. The dependence of the coupling field and coupling current losses on the twist pitch has been analysed and compared with the theoretical predictions.

  4. Magnetically attached sputter targets

    DOEpatents

    Makowiecki, D.M.; McKernan, M.A.

    1994-02-15

    An improved method and assembly for attaching sputtering targets to cathode assemblies of sputtering systems which includes a magnetically permeable material is described. The magnetically permeable material is imbedded in a target base that is brazed, welded, or soldered to the sputter target, or is mechanically retained in the target material. Target attachment to the cathode is achieved by virtue of the permanent magnets and/or the pole pieces in the cathode assembly that create magnetic flux lines adjacent to the backing plate, which strongly attract the magnetically permeable material in the target assembly. 11 figures.

  5. Magnetically attached sputter targets

    DOEpatents

    Makowiecki, Daniel M.; McKernan, Mark A.

    1994-01-01

    An improved method and assembly for attaching sputtering targets to cathode assemblies of sputtering systems which includes a magnetically permeable material. The magnetically permeable material is imbedded in a target base that is brazed, welded, or soldered to the sputter target, or is mechanically retained in the target material. Target attachment to the cathode is achieved by virtue of the permanent magnets and/or the pole pieces in the cathode assembly that create magnetic flux lines adjacent to the backing plate, which strongly attract the magnetically permeable material in the target assembly.

  6. Optimized anisotropic magnetoelectric response of Fe61.6Co16.4Si10.8B11.2/PVDF/Fe61.6Co16.4Si10.8B11.2 laminates for AC/DC magnetic field sensing

    NASA Astrophysics Data System (ADS)

    Reis, S.; Silva, M. P.; Castro, N.; Correia, V.; Gutierrez, J.; Lasheras, A.; Lanceros-Mendez, S.; Martins, P.

    2016-05-01

    The anisotropic magnetoelectric (ME) effect on a Fe61.6Co16.4Si10.8B11.2/PVDF Fe61.6Co16.4Si10.8B11.2 laminate composite has been used for the development of a magnetic field sensor able to detect both the magnitude and direction of AC and DC magnetic fields. The accuracy (99% for both AC and DC sensors), linearity (92% for the DC sensor and 99% for the AC sensor) and reproducibility (99% for both sensors) indicate the suitability of the sensor for applications. Furthermore, the sensitivity of the Fe61.6Co16.4Si10.8B11.2/PVDF/Fe61.6Co16.4Si10.8B11.2 anisotropic magnetic sensor—15 and 1400 mV Oe-1 for the DC and AC fields, respectively—are the highest reported in the literature for polymer-based ME materials. Such features, combined with its flexibility, versatility, light weight, low cost and low-temperature fabrication, lead to the suitability of the developed sensor for use in magnetic sensor applications.

  7. EPA Permeable Surface Research - Poster

    EPA Science Inventory

    EPA recognizes permeable surfaces as an effective post-construction infiltration-based Best Management Practice to mitigate the adverse effects of stormwater runoff. The professional user community conceptually embraces permeable surfaces as a tool for making runoff more closely...

  8. AC magnetic measurement of LiFeAs at pressures up to 5.2 GPa: The relation between T c and the structural parameters

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Shuhei; Yamaguchi, Nobuhiro; Mito, Masaki; Deguchi, Hiroyuki; Baker, Peter. J.; Blundell, Stephen. J.; Pitcher, Michael. J.; Parker, Dinah. R.; Clarke, Simon. J.

    2013-08-01

    The pressure effects on the 111-type Fe-based superconductor LiFeAs were investigated through AC susceptibility measurements and X-ray diffraction experiments, and revealed a correlation between the superconducting transition temperature ( T c ) and the As-Fe-As bond angle ( α) rather than the height of As from the Fe layers ( h As). As the pressure was increased, T c of 17 K at P = 0 GPa decreased down to 10 K at P = 5.2 GPa. According to a previous report from an X-ray diffraction experiment, α changes from 101.5° at 0 GPa to 97.8° at 17 GPa. The obtained change in T c is consistent with Lee et al.'s plot of T c as a function of α, and from this result, we conclude that T c will fall to zero at around α = 98°.

  9. Liquid-permeable electrode

    DOEpatents

    Folser, George R.

    1980-01-01

    Electrodes for use in an electrolytic cell, which are liquid-permeable and have low electrical resistance and high internal surface area are provided of a rigid, porous, carbonaceous matrix having activated carbon uniformly embedded throughout. The activated carbon may be catalyzed with platinum for improved electron transfer between electrode and electrolyte. Activated carbon is mixed with a powdered thermosetting phenolic resin and compacted to the desired shape in a heated mold to melt the resin and form the green electrode. The compact is then heated to a pyrolyzing temperature to carbonize and volatilize the resin, forming a rigid, porous structure. The permeable structure and high internal surface area are useful in electrolytic cells where it is necessary to continuously remove the products of the electrochemical reaction.

  10. Stainless Steel Permeability

    SciTech Connect

    Buchenauer, Dean A.; Karnesky, Richard A.

    2015-09-01

    An understanding of the behavior of hydrogen isotopes in materials is critical to predicting tritium transport in structural metals (at high pressure), estimating tritium losses during production (fission environment), and predicting in-vessel inventory for future fusion devices (plasma driven permeation). Current models often assume equilibrium diffusivity and solubility for a class of materials (e.g. stainless steels or aluminum alloys), neglecting trapping effects or, at best, considering a single population of trapping sites. Permeation and trapping studies of the particular castings and forgings enable greater confidence and reduced margins in the models. For FY15, we have continued our investigation of the role of ferrite in permeation for steels of interest to GTS, through measurements of the duplex steel 2507. We also initiated an investigation of the permeability in work hardened materials, to follow up on earlier observations of unusual permeability in a particular region of 304L forgings. Samples were prepared and characterized for ferrite content and coated with palladium to prevent oxidation. Issues with the poor reproducibility of measurements at low permeability were overcome, although the techniques in use are tedious. Funding through TPBAR and GTS were secured for a research grade quadrupole mass spectrometer (QMS) and replacement turbo pumps, which should improve the fidelity and throughput of measurements in FY16.

  11. AC losses in multifilamentary Bi(2223) tapes with an interfilamentary resistive carbonate barrier

    NASA Astrophysics Data System (ADS)

    Eckelmann, H.; Quilitz, M.; Oomen, M.; Leghissa, M.; Goldacker, W.

    1998-12-01

    For the most common AC application frequencies, the main component of the AC losses in multifilamentary Bi(2223) tapes are caused by hysteresis- and coupling losses. These losses can be reduced enhancing the matrix resistivity and applying a twist to the filaments. We report on the AC loss properties of 37-filament tapes with AgAu (8 wt.%) matrix, and novel 19-filament tapes with SrCO 3 barriers between the filaments. We performed transport AC loss and magnetic AC loss measurements in parallel and perpendicular magnetic fields. Both kinds of tapes were also prepared with filament twists below a twist pitch of 20 mm. The influence of the different tape modifications on the AC loss behaviour is presented and compared with theoretical models to understand the effect of the resistive matrix. In the case of magnetic AC loss measurements, reduced AC losses due to decoupled filaments were observed for the twisted tapes with a resistive matrix in low parallel fields.

  12. ACS: ALMA Common Software

    NASA Astrophysics Data System (ADS)

    Chiozzi, Gianluca; Šekoranja, Matej

    2013-02-01

    ALMA Common Software (ACS) provides a software infrastructure common to all ALMA partners and consists of a documented collection of common patterns and components which implement those patterns. The heart of ACS is based on a distributed Component-Container model, with ACS Components implemented as CORBA objects in any of the supported programming languages. ACS provides common CORBA-based services such as logging, error and alarm management, configuration database and lifecycle management. Although designed for ALMA, ACS can and is being used in other control systems and distributed software projects, since it implements proven design patterns using state of the art, reliable technology. It also allows, through the use of well-known standard constructs and components, that other team members whom are not authors of ACS easily understand the architecture of software modules, making maintenance affordable even on a very large project.

  13. Magnetostrictive materials and method for improving AC characteristics in same

    DOEpatents

    Pulvirenti, Patricia P.; Jiles, David C.

    2001-08-14

    The present invention provides Terfenol-D alloys ("doped" Terfenol) having optimized performances under the condition of time-dependent magnetic fields. In one embodiment, performance is optimized by lowering the conductivity of Terfenol, thereby improving the frequency response. This can be achieved through addition of Group III or IV elements, such as Si and Al. Addition of these types of elements provides scattering sites for conduction electrons, thereby increasing resistivity by 125% which leads to an average increase in penetration depth of 80% at 1 kHz and an increase in energy conversion efficiency of 55%. The permeability of doped Terfenol remains constant over a wider frequency range as compared with undoped Terfenol. These results demonstrate that adding impurities, such as Si and Al, are effective in improving the ac characteristics of Terfenol. A magnetoelastic Gruneisen parameter, .gamma..sub.me, has also been derived from the thermodynamic equations of state, and provides another means by which to characterize the coupling efficiency in magnetostrictive materials on a more fundamental basis.

  14. Barometric pressure transient testing applications at the Nevada Test Site: formation permeability analysis. Final report

    SciTech Connect

    Hanson, J.M.

    1984-12-01

    The report evaluates previous investigations of the gas permeability of the rock surrounding emplacement holes at the Nevada Test Site. The discussion sets the framework from which the present uncertainty in gas permeability can be overcome. The usefulness of the barometric pressure testing method has been established. Flow models were used to evaluate barometric pressure transients taken at NTS holes U2fe, U19ac and U20ai. 31 refs., 103 figs., 18 tabs. (ACR)

  15. Antifriction coatings based on a-C for biomedicine applications

    NASA Astrophysics Data System (ADS)

    Yurjev, Y. N.; Kiseleva, D. V.; Zaitcev, D. A.; Sidelev, D. V.; Korneva, O. S.

    2016-01-01

    This article reports on the investigation of mechanical properties of carbon films deposited by dual magnetron sputtering system with closed and mirror magnetic field. There is shown that a-C films with predominantly sp2-phase have relatively high hardness (up to 20 GPa) and low friction index (∼0.01). The influence of magnetic field on friction index is determined. The analysis of experimental data shows the obtained a-C samples can be used for biomedicine applications.

  16. Relative permeability through fractures

    SciTech Connect

    Diomampo, Gracel, P.

    2001-08-01

    The mechanism of two-phase flow through fractures is of importance in understanding many geologic processes. Currently, two-phase flow through fractures is still poorly understood. In this study, nitrogen-water experiments were done on both smooth and rough parallel plates to determine the governing flow mechanism for fractures and the appropriate methodology for data analysis. The experiments were done using a glass plate to allow visualization of flow. Digital video recording allowed instantaneous measurement of pressure, flow rate and saturation. Saturation was computed using image analysis techniques. The experiments showed that gas and liquid phases flow through fractures in nonuniform separate channels. The localized channels change with time as each phase path undergoes continues breaking and reforming due to invasion of the other phase. The stability of the phase paths is dependent on liquid and gas flow rate ratio. This mechanism holds true for over a range of saturation for both smooth and rough fractures. In imbibition for rough-walled fractures, another mechanism similar to wave-like flow in pipes was also observed. The data from the experiments were analyzed using Darcy's law and using the concept of friction factor and equivalent Reynold's number for two-phase flow. For both smooth- and rough-walled fractures a clear relationship between relative permeability and saturation was seen. The calculated relative permeability curves follow Corey-type behavior and can be modeled using Honarpour expressions. The sum of the relative permeabilities is not equal one, indicating phase interference. The equivalent homogeneous single-phase approach did not give satisfactory representation of flow through fractures. The graphs of experimentally derived friction factor with the modified Reynolds number do not reveal a distinctive linear relationship.

  17. Permittivity and permeability of semi-infinite metamaterial

    NASA Astrophysics Data System (ADS)

    Porvatkina, O. V.; Tishchenko, A. A.; Strikhanov, M. N.

    2016-08-01

    In our work we investigate dielectric and magnetic properties of semi-infinite metamaterial consisting of particles of different possible nature: atoms, molecules, nanoparticles, etc. It is important that these particles would have magnetic properties. Polarization of a near-surface layer is known to differ from its bulk value for non-magnetic materials; for magnetic materials, including metamaterials, the situation should be similar, which is the subject of our research. We obtain analogues of the Clausius-Mossotti relation both for permittivity and permeability taking into account the local field effects in the longwave approximation for semi-infinite metamaterial. These relations describe the connection between macroscopic characteristics of the semi-infinite metamaterial (permittivity and permeability) and characteristics of constituent particles (dielectric polarizability and magnetic polarizability), which is a bright example of multi-scale approach - method very popular today in physical and computer simulating.

  18. Variation in energy stored and dissipated in type-II superconductor in applied ac magnetic field with relative phase of two sinusoidal components of the field

    NASA Astrophysics Data System (ADS)

    Janů, Zdeněk; Chagovets, Tymofiy

    2017-01-01

    We show that both the energy stored and dissipated by a system with hysteretic nonlinearity in an applied field varies with the relative phase of the sinusoidal components of the field, even if the magnitude of these components, and thus an effective value of the field, are kept constant. The explored system is a type-II superconductor in the critical state subjected to a time varying applied magnetic field. Complete analytical expressions for hysteresis loops, determined from basic physical phenomena, are known for this system. A theoretically predicted variation in the energy is in good agreement with our experimental measurements.

  19. The evaluation of rock permeability with streaming current measurements

    NASA Astrophysics Data System (ADS)

    Wang, Jun; Hu, Hengshan; Guan, Wei

    2016-09-01

    Rock permeability is an important parameter for the formation evaluation. In this paper, a new method with streaming current is proposed to determine the sample permeability based on the electrokinetic effects, and is proved by the experimental measurements. Corresponding to this method, we have designed an experimental setup and a test system, then performed the streaming current (potential) and electro-osmosis pressure experiments with 23 sandstone samples at 0.05 mol l-1 NaCl solution. The streaming current (potential) coefficient and electro-osmosis pressure coefficient are obtained, respectively, with the experimental data at low frequencies with AC lock-in technique. The electrokinetic permeabilities are further calculated with these coefficients. The results are consistent well with the gas permeability measured with Darcy's law, which verifies the current method for estimating rock permeability. Our measurements are also analysed and compared with previous measurements. The results indicate that our method can reflect the essence of electrokinetic effects better and simplify the electrokinetic measurements as well. In addition, we discuss the influences of experimental artefacts (core holder and confining pressure installation) on the electrokinetic data. The results show that the trough phenomenon, appeared in frequency curves of streaming current (potential) coefficients, is induced by the resonance of the core-holder/vibrator system. This is important for the design of electrokinetic setup and the analysis of low-frequency response of the electrokinetic coupling coefficients.

  20. Alternate current magnetic property characterization of nonstoichiometric zinc ferrite nanocrystals for inductor fabrication via a solution based process

    NASA Astrophysics Data System (ADS)

    Yun, Hongseok; Kim, Jungkwun; Paik, Taejong; Meng, Lingyao; Jo, Pil Sung; Kikkawa, James M.; Kagan, Cherie R.; Allen, Mark G.; Murray, Christopher B.

    2016-03-01

    We investigate the ac magnetic behavior of solution processable, non-stoichiometric zinc ferrite nanocrystals with a series of sizes and zinc concentrations. Nearly monodisperse ZnxFe3-xO4 nanocrystals (x = 0-0.25) with an average size ranging from 7.4 nm to 13.8 nm are synthesized by using a solvothermal method. All the nanocrystals are in a superparamagnetic state at 300 K, which is confirmed by Superconductive Quantum Interference Device magnetometry. Due to the doping of non-magnetic Zn2+ into A site of ferrite, the saturation magnetization of nanocrystals increases as the size and Zn concentration increases. The ac magnetic permeability measurements at radio frequencies reveal that the real part of the magnetic permeability of similarly sized ferrite nanocrystals can be enhanced by almost twofold as the Zn2+ doping level increases from 0 to 0.25. The integration of 12.3 nm Zn0.25Fe2.75O4 nanocrystals into a toroidal inductor and a solenoid inductor prepared via a simple solution cast process yields a higher quality factors than air core inductors with the same geometries up to 5 MHz and 9 MHz, respectively, which is in the regime of the switching frequencies for the advanced integrated power converters.

  1. A study of the spin-gaps in the organic conductor Perylene2[Pt(mnt)2] with the application of high magnetic field using an inductive AC susceptibility method

    NASA Astrophysics Data System (ADS)

    Winter, Laurel; Brooks, James; Schlottmann, Pedro; Almeida, Manuel; Benjamin, Shermane; Bourbonnais, Claude

    2014-03-01

    To further understand the spin-charge coupling present in the dual-chain organic conductor Per2[Pt(mnt)2] we utilized an inductive ac susceptibility method to study the spin-Peierls (SP) ordered state.2 Besides reaffirming the coexistence of the SP-CDW below 8 K and 20 T, our measurements also showed the emergence of a second spin-gapped phase above 20 T that coincides with the previous observed field-induced insulating phase. Our results provide support for the continued coupling of the charge and spin order parameters even in high magnetic fields and hints at the possibility of further spin and charge gaps above 45 T.2 L.E. Winter, J.S. Brooks, P. Schlottmann, M. Almeida, S. Benjamin, and C, Bourbonnais, Europhys. Lett., 103 (2013) 37008. This work was supported by NSF-DMR 1005293 and the NHMFL is supported by the NSF-DMR-1157490 and the State of Florida. PS is supported by DOE under grant DE-FG02-98ER45707.

  2. Optimization of spin-torque switching using AC and DC pulses

    SciTech Connect

    Dunn, Tom; Kamenev, Alex

    2014-06-21

    We explore spin-torque induced magnetic reversal in magnetic tunnel junctions using combined AC and DC spin-current pulses. We calculate the optimal pulse times and current strengths for both AC and DC pulses as well as the optimal AC signal frequency, needed to minimize the Joule heat lost during the switching process. The results of this optimization are compared against numeric simulations. Finally, we show how this optimization leads to different dynamic regimes, where switching is optimized by either a purely AC or DC spin-current, or a combination AC/DC spin-current, depending on the anisotropy energies and the spin-current polarization.

  3. Rocks of low permeability

    NASA Astrophysics Data System (ADS)

    The 17th International Congress of the IAH (International Association of Hydrogeologists) will meet in Tucson, Ariz., January 7-10, 1985. The deadline for abstracts is March 1, 1984, and final papers are due October 15, 1984.The topic of the congress will be “Hydrogeology of Rocks of Low Permeability,” and speakers will include W. Back, J. F. Bredehoeft, G. de Marsily, J. E. Gale, P. Fritz, L. W. Gelhar, G. E. Grisak, C. W. Kreitler, M. R. Llamas, T. N. Narasimhan, I. Neretnieks, and E. P. Weeks. The congress will conclude with a panel discussion moderated by S. P. Neuman. Panelists include S. N. Davis, G. de Marsily, R. A. Freeze, P. A. Witherspoon, and I. Neretnieks.

  4. Placental Permeability of Lead

    PubMed Central

    Carpenter, Stanley J.

    1974-01-01

    The detection of lead in fetal tissues by chemical analysis has long been accepted as prima facie evidence for the permeability of the placenta to this nonessential trace metal. However, only a few investigations, all on lower mammalian species, have contributed any direct experimental data bearing on this physiological process. Recent radioactive tracer and radioautographic studies on rodents have shown that lead crosses the placental membranes rapidly and in significant amounts even at relatively low maternal blood levels. While it is not possible to extrapolate directly the results of these experiments to humans because of differences in placental structure and other factors, the results do serve as a warning of the possible hazard to the human embryo and fetus of even low levels of lead in the maternal system. PMID:4857497

  5. A Magnetic Paradox

    ERIC Educational Resources Information Center

    Arndt, Ebe

    2006-01-01

    Two recent articles in this journal described how an air core solenoid connected to an ac power source may restore the magnetization of a bar magnet with an alternating magnetic field (see Figs. 1 and 2). Although we are quite accustomed to using a constant magnetic field in an air core solenoid to remagnetize a ferromagnet, it is puzzling that we…

  6. Microfabricated AC impedance sensor

    DOEpatents

    Krulevitch, Peter; Ackler, Harold D.; Becker, Frederick; Boser, Bernhard E.; Eldredge, Adam B.; Fuller, Christopher K.; Gascoyne, Peter R. C.; Hamilton, Julie K.; Swierkowski, Stefan P.; Wang, Xiao-Bo

    2002-01-01

    A microfabricated instrument for detecting and identifying cells and other particles based on alternating current (AC) impedance measurements. The microfabricated AC impedance sensor includes two critical elements: 1) a microfluidic chip, preferably of glass substrates, having at least one microchannel therein and with electrodes patterned on both substrates, and 2) electrical circuits that connect to the electrodes on the microfluidic chip and detect signals associated with particles traveling down the microchannels. These circuits enable multiple AC impedance measurements of individual particles at high throughput rates with sufficient resolution to identify different particle and cell types as appropriate for environmental detection and clinical diagnostic applications.

  7. Optical, magnetic, and microwave properties of Ni/NiO nanoparticles

    NASA Astrophysics Data System (ADS)

    Rostamnejadi, Ali; Bagheri, Saber

    2017-04-01

    In this research, the optical, magnetic, and microwave properties of NiO and Ni/NiO nanoparticles have been studied. The absorbance spectra of the samples show the electronic d-d excitations with energy band gap of about 3.8 eV. The magnetization measurement confirms the existence of ferromagnetic phase at room temperature, which could be originated from the uncompensated surface spins or ferromagnetic clusters in the antiferromagnetic ground state of NiO nanoparticles. The microwave parameters such as ac conductivity, skin depth, electric and magnetic loss tangents, attenuation constant, and reflection loss have been calculated. While both magnetic and dielectric relaxation processes have been observed in the complex permeability and permittivity, the microwave absorption is mainly attributed to the dielectric relaxation processes.

  8. Permeable Boundaries in Organizational Learning

    NASA Astrophysics Data System (ADS)

    Hazy, James K.; Tivnan, Brian F.; Schwandt, David R.

    The nature of the organizational boundary is investigated in the context of organizational learning. Boundary permeability is defined and hypotheses relating it to performance are tested computationally using data from 5,500 artificial organizations. We find that matching boundary permeability to the environment predicts both agent and organization survival.

  9. Permeability-porosity relationships in sedimentary rocks

    USGS Publications Warehouse

    Nelson, Philip H.

    1994-01-01

    In many consolidated sandstone and carbonate formations, plots of core data show that the logarithm of permeability (k) is often linearly proportional to porosity (??). The slope, intercept, and degree of scatter of these log(k)-?? trends vary from formation to formation, and these variations are attributed to differences in initial grain size and sorting, diagenetic history, and compaction history. In unconsolidated sands, better sorting systematically increases both permeability and porosity. In sands and sandstones, an increase in gravel and coarse grain size content causes k to increase even while decreasing ??. Diagenetic minerals in the pore space of sandstones, such as cement and some clay types, tend to decrease log(k) proportionately as ?? decreases. Models to predict permeability from porosity and other measurable rock parameters fall into three classes based on either grain, surface area, or pore dimension considerations. (Models that directly incorporate well log measurements but have no particular theoretical underpinnings from a fourth class.) Grain-based models show permeability proportional to the square of grain size times porosity raised to (roughly) the fifth power, with grain sorting as an additional parameter. Surface-area models show permeability proportional to the inverse square of pore surface area times porosity raised to (roughly) the fourth power; measures of surface area include irreducible water saturation and nuclear magnetic resonance. Pore-dimension models show permeability proportional to the square of a pore dimension times porosity raised to a power of (roughly) two and produce curves of constant pore size that transgress the linear data trends on a log(k)-?? plot. The pore dimension is obtained from mercury injection measurements and is interpreted as the pore opening size of some interconnected fraction of the pore system. The linear log(k)-?? data trends cut the curves of constant pore size from the pore-dimension models

  10. Permeability tensor for a metamaterial adjacent to a metal

    NASA Astrophysics Data System (ADS)

    Porvatkina, Olga V.; Tishchenko, Alexey A.; Strikhanov, Mikhail N.

    2017-01-01

    In our work, we investigate magnetic properties of metamaterial-metal interface with the help of the local field theory combined with the method of images. Proceeding from microscopic description of the substance and calculating its macroscopic properties, for the first time the modified Clausius-Mossotti relation has been obtained for permeability of the metamaterial bordering a metal.

  11. AC magnetohydrodynamic microfluidic switch

    SciTech Connect

    Lemoff, A V; Lee, A P

    2000-03-02

    A microfluidic switch has been demonstrated using an AC Magnetohydrodynamic (MHD) pumping mechanism in which the Lorentz force is used to pump an electrolytic solution. By integrating two AC MHD pumps into different arms of a Y-shaped fluidic circuit, flow can be switched between the two arms. This type of switch can be used to produce complex fluidic routing, which may have multiple applications in {micro}TAS.

  12. Dynamic performance of a disk-type magnetorheological fluid damper under AC excitation

    NASA Astrophysics Data System (ADS)

    Zhu, Changsheng

    2005-02-01

    It is shown that the dynamic behaviour of a disk-type magnetorheological (MR) fluid damper developed on shear mode for rotational machinery can be controlled by application of an external DC magnetic field produced by a low voltage electromagnetic coil and that the disk-type MR fluid damper can effectively attenuate the rotor vibration. In this paper, the dynamic behaviour of the disk-type MR fluid damper for attenuating rotor vibration under AC sinusoidal magnetic field is experimentally studied on a flexible rotor. It is shown that as the frequency of applied AC sinusoidal magnetic field increases, the capability of the disk-type MR fluid damper to attenuate rotor vibration significantly reduces. There is a maximum frequency of AC sinusoidal magnetic field for a given applied magnetic field strength to realize the MR effect. When the frequency of AC sinusoidal magnetic field is over the maximum frequency, the MR activity almost completely disappears and the dynamic behaviour of the disk-type MR fluid dampers under a high frequency AC magnetic field is the same as that without magnetic field. For a given sinusoidal magnetic field frequency, there is also a minimum AC sinusoidal magnetic field to active the MR effect. In the rotor vibration control of view, it is not necessary to use the AC power supply for disk-type MR fluid dampers.

  13. Theoretical analysis on ac susceptibility measurements of superconductor tapes

    NASA Astrophysics Data System (ADS)

    Chen, Du-Xing; Sun, Yue-Ming; Li, Shuo; Fang, Jin

    2017-02-01

    Perpendicular ac susceptibility χ ={χ\\prime}-j{χ\\prime \\prime} of a superconducting long tape defined by magnetic moment and determined inductively by magnetic flux is calculated using Brandt’s technique from a power-law dependence of electric field on sheet current density. The requirements of χ measurements to the experimental setup and procedure are discussed based on the calculation results.

  14. Permeable membrane experiment

    NASA Technical Reports Server (NTRS)

    Slavin, Thomas J.; Cao, Tuan Q.; Kliss, Mark H.

    1993-01-01

    The purpose of the Permeable Membrane Experiment is to gather flight data on three areas of membrane performance that are influenced by the presence of gravity. These areas are: (1) Liquid/gas phase separation, (2) gas bubble interference with diffusion through porous membranes and (3) wetting characteristics of hydrophilic membrane surfaces. These data are important in understaning the behavior of membrane/liquid/gas interfaces where surface tension forces predominate. The data will be compared with 1-g data already obtained and with predicted micrograviity behavior. The data will be used to develop designs for phase separation and plant nutrient delivery systems and will be available to the life support community for use in developing technologies which employ membranes. A conceptual design has been developed to conduct three membrane experiments, in sequence, aboard a single Complex Autonomous Payload (CAP) carrier to be carried in the Shuttle Orbiter payload bay. One experiment is conducted for each of the three membrane performance areas under study. These experiments are discussed in this paper.

  15. Relative Permeability of Fractured Rock

    SciTech Connect

    Mark D. Habana

    2002-06-30

    Contemporary understanding of multiphase flow through fractures is limited. Different studies using synthetic fractures and various fluids have yielded different relative permeability-saturation relations. This study aimed to extend the understanding of multiphase flow by conducting nitrogen-water relative permeability experiments on a naturally-fractured rock from The Geysers geothermal field. The steady-state approach was used. However, steady state was achieved only at the endpoint saturations. Several difficulties were encountered that are attributed to phase interference and changes in fracture aperture and surface roughness, along with fracture propagation/initiation. Absolute permeabilities were determined using nitrogen and water. The permeability values obtained change with the number of load cycles. Determining the absolute permeability of a core is especially important in a fractured rock. The rock may change as asperities are destroyed and fractures propagate or st rain harden as the net stresses vary. Pressure spikes occurred in water a solute permeability experiments. Conceptual models of an elastic fracture network can explain the pressure spike behavior. At the endpoint saturations the water relative permeabilities obtained are much less than the nitrogen gas relative permeabilities. Saturations were determined by weighing and by resistivity calculations. The resistivity-saturation relationship developed for the core gave saturation values that differ by 5% from the value determined by weighing. Further work is required to complete the relative permeability curve. The steady-state experimental approach encountered difficulties due to phase interference and fracture change. Steady state may not be reached until an impractical length of time. Thus, unsteady-state methods should be pursued. In unsteady-state experiments the challenge will be in quantifying rock fracture change in addition to fluid flow changes.

  16. MAGNETS

    DOEpatents

    Hofacker, H.B.

    1958-09-23

    This patent relates to nmgnets used in a calutron and more particularly to means fur clamping an assembly of magnet coils and coil spacers into tightly assembled relation in a fluid-tight vessel. The magnet comprises windings made up of an assembly of alternate pan-cake type coils and spacers disposed in a fluid-tight vessel. At one end of the tank a plurality of clamping strips are held firmly against the assembly by adjustable bolts extending through the adjacent wall. The foregoing arrangement permits taking up any looseness which may develop in the assembly of coils and spacers.

  17. Thermal treatment of low permeability soils using electrical resistance heating

    SciTech Connect

    Udell, K.S.

    1996-08-01

    The acceleration of recovery rates of second phase liquid contaminants from the subsurface during gas or water pumping operations is realized by increasing the soil and ground water temperature. Electrical heating with AC current is one method of increasing the soil and groundwater temperature and has particular applicability to low permeability soils. Several mechanisms have been identified that account for the enhanced removal of the contaminants during electrical heating. These are vaporization of liquid contaminants with low boiling points, temperature-enhanced evaporation rates of semi-volatile components, and removal of residual contaminants by the boiling of residual water. Field scale studies of electrical heating and fluid extraction show the effectiveness of this technique and its applicability to contaminants found both above and below the water table and within low permeability soils. 10 refs., 8 figs.

  18. Geothermal Permeability Enhancement - Final Report

    SciTech Connect

    Joe Beall; Mark Walters

    2009-06-30

    The overall objective is to apply known permeability enhancement techniques to reduce the number of wells needed and demonstrate the applicability of the techniques to other undeveloped or under-developed fields. The Enhanced Geothermal System (EGS) concept presented in this project enhances energy extraction from reduced permeability zones in the super-heated, vapor-dominated Aidlin Field of the The Geysers geothermal reservoir. Numerous geothermal reservoirs worldwide, over a wide temperature range, contain zones of low permeability which limit the development potential and the efficient recovery of heat from these reservoirs. Low permeability results from poorly connected fractures or the lack of fractures. The Enhanced Geothermal System concept presented here expands these technologies by applying and evaluating them in a systematic, integrated program.

  19. Effect of uniaxial stress on the reversible and irreversible permeabilities of 2% Mn pipeline steel

    SciTech Connect

    Makar, J.M.; Atherton, D.L. . Dept. of Physics)

    1994-07-01

    The results of a study of the effects of constant uniaxial stress on the irreversible and reversible differential permeabilities of minor and saturation major hysteresis loops are presented, extending an earlier study which studied those permeability components on the initial magnetization curve. Tension was found to increase both the reversible and irreversible components of the saturation major loop differential permeability in the low magnetization region, and to decrease them in the high magnetization region. The opposite effect was found for compression. This effect was explained as the result of changes in the domain structure of the sample when stressed and a resulting change in the ratio of 90[degree] of 180[degree] domain walls. The differences between the upper and lower branches of the saturation major hysteresis loop reversible relative differential permeability were found to increase in tension and decrease in compression, with more complicated behavior occurring in the irreversible component. Minor loop behavior was also found to vary depending on the magnetization of the sample. In the low magnetization region tension was found to produce higher values and larger variations in both components of the relative differential permeability than the unstressed case, while compression produced lower values and smaller variations. The opposite behavior was found to be true in the high magnetization region, while an intermediate behavior with little or no change in both the relative differential permeability components was found to exist between the two extreme cases.

  20. Permeability of soils in Mississippi

    USGS Publications Warehouse

    O'Hara, Charles G.

    1994-01-01

    The permeability of soils in Mississippi was determined and mapped using a geographic information system (GIS). Soil permeabilities in Mississippi were determined to range in value from nearly 0.0 to values exceeding 5.0 inches per hour. The U.S. Soil Conservation Service's State Soil Geographic Data Base (STATSGO) was used as the primary source of data for the determination of area-weighted soil permeability. STATSGO provides soil layer properties that are spatially referenced to mapped areas. These mapped areas are referred to as polygons in the GIS. The polygons arc boundaries of soils mapped as a group and are given unique Map Unit Identifiers (MUIDs). The data describing the physical characteristics of the soils within each polygon are stored in a tabular data base format and are referred to as attributes. The U.S. Soil Conservation Service developed STATSGO to be primarily used as a guide for regional resource planning, management, and monitoring. STATSGO was designed so that soil information could be extracted from properties tables at the layer level, combined by component, and statistically expanded to cover the entire map unit. The results of this study provide a mapped value for permeability which is representative of the vertical permeability of soils in that area. The resultant permeability map provides a representative vertical soil permeability for a given area sufficient for county, multi- county, and area planning, and will be used as the soil permeability data component in the evaluation of the susceptibility of major aquifers to contami- nation in Mississippi.

  1. Tuning polymer nanocomposite morphology: AC electric field manipulation of epoxy-montmorillonite (clay) suspensions

    SciTech Connect

    Koerner,H.; Jacobs, D.; Tomlin, D.; Busbee, J.; Vaia, R.

    2004-01-01

    The next revolutionary leap forward for polymer nano-'composites' necessitates the development of tools to transform the currently random or ill-defined nanoscale morphologies into compositionally and spatially engineered hierarchal structures, paralleling that underpinning conventional continuous fiber reinforced composites and enabling experimental verification of morphology-mechanical property correlations. Here in, utilization of AC electric fields of modest strength (1-10 V/micron) is demonstrated as a general approach to align organically modified layered silicates (OLS) parallel to the electric field-enhancing CTE, modulus and optical clarity in the reinforced direction. Interfacial polarization arising from electrophoric motion of the organic-modifier on the layer surface induces a dipole parallel to the plane of the layer, which couples to the external field. Comparably, application of a static magnetic field (0.5-2 T) induces alignment of the layers parallel or perpendicular to the field, depending on the chemical composition of the OLS. The impact of field magnitude, field frequency, dielectric permittivity and magnetic permeability of the system is discussed to elucidate the molecular characteristics of induced dipole formation and establish the limits of the process.

  2. Permeability of cork to gases.

    PubMed

    Faria, David P; Fonseca, Ana L; Pereira, Helen; Teodoro, Orlando M N D

    2011-04-27

    The permeability of gases through uncompressed cork was investigated. More than 100 samples were assessed from different plank qualities to provide a picture of the permeability distribution. A novel technique based on a mass spectrometer leak detector was used to directly measure the helium flow through the central area of small disks 10 mm in diameter and 2 mm thick. The permeability for nitrogen, oxygen, and other gases was measured by the pressure rise technique. Boiled and nonboiled cork samples from different sections were evaluated. An asymmetric frequency distribution ranging 3 orders of magnitude (roughly from 1 to 1000 μmol/(cm·atm·day)) for selected samples without macroscopic defects was found, having a peak below 100 μmol/(cm·atm·day). Correlation was found between density and permeability: higher density samples tend to show lower permeability. However, boiled cork showed a mean lower permeability despite having a lower density. The transport mechanism of gases through cork was also examined. Calculations suggest that gases permeate uncompressed cork mainly through small channels between cells under a molecular flow regime. The diameter of such channels was estimated to be in the range of 100 nm, in agreement with the plasmodesmata size in the cork cell walls.

  3. Permeability theory and Palace Athena.

    PubMed

    Stamps, Arthur E

    2013-06-01

    Permeability theory suggests that safety in environments depends on how far and how easily one can perceive or move through environments. Parts of environments that limit perception or retard locomotion elicit impressions of being enclosed, so properties of environments that influence perceived enclosure are important in permeability theory. One prediction of permeability theory is that the more permeable the boundary, the less enclosed the region within that boundary will seem to be. Another prediction is that boundary depth will have little influence on perceived enclosure. These predictions were tested in the venue of Greek temples. 30 participants were tested (14 men, 16 women; M age = 40 yr.), who rated perceived enclosure for 18 stimuli. The stimuli were constructed using a virtual scene from the Tholos in Delphi with the positions of the columns forming the boundaries. The boundaries were designed to have different levels of permeability and depth. Data were analyzed in terms of effect sizes and focused comparisons. Results indicated that perceived enclosure was most strongly influenced by the visual permeability of the boundary, while depth of boundary had a much smaller effect on perceived enclosure.

  4. ACS CCDs daily monitor

    NASA Astrophysics Data System (ADS)

    Sirianni, Marco

    2006-07-01

    This program consists of a set of basic tests to monitor, the read noise, thedevelopment of hot pixels and test for any source of noise in ACS CCDdetectors. The files, biases and dark will be used to create referencefiles for science calibration. This programme will be for the entire lifetime of ACS.For cycle 15 the program will cover 18 months 12.1.06->05.31.08and it has been divied into three different proposal each covering six months.The three poroposal are 11041-11042-11043.

  5. ac bidirectional motor controller

    NASA Technical Reports Server (NTRS)

    Schreiner, K.

    1988-01-01

    Test data are presented and the design of a high-efficiency motor/generator controller at NASA-Lewis for use with the Space Station power system testbed is described. The bidirectional motor driver is a 20 kHz to variable frequency three-phase ac converter that operates from the high-frequency ac bus being designed for the Space Station. A zero-voltage-switching pulse-density-modulation technique is used in the converter to shape the low-frequency output waveform.

  6. Diffusive suppression of AC-Stark shifts in atomic magnetometers

    PubMed Central

    Sulai, I. A.; Wyllie, R.; Kauer, M.; Smetana, G. S.; Wakai, R. T.; Walker, T. G.

    2016-01-01

    In atomic magnetometers, the vector AC-Stark shift associated with circularly polarized light generates spatially varying effective magnetic fields, which limit the magnetometer response and serve as sources of noise. We describe a scheme whereby optically pumping a small subvolume of the magnetometer cell and relying on diffusion to transport polarized atoms allows a magnetometer to be operated with minimal sensitivity to the AC-Stark field. © 2013 Optical Society of America PMID:23503278

  7. Fast approximate EM induction modeling of metallic and UXO targets using a permeable prism

    NASA Astrophysics Data System (ADS)

    Asten, Michael W.; Duncan, Andrew C.

    2007-03-01

    The time-domain EM induction response of non-magnetic and magnetic targets can be approximated using a conductive permeable prism composed of six faces of conductive plates, each face being composed of a set of conductive ribbons. The effect of magnetic permeability is included by the use of two "apparent flux gathering" coefficients, and two "effective magnetic permeability" coefficients, in the axial and transverse directions. These four magnetic property coefficients are a function of physical properties and geometry of the target, but are independent of prism orientation relative to a transmitter. The approximation algorithm is computationally fast, allowing inversions for target parameters to be achieved in seconds. The model is tested on profiles acquired with a Geonics EM63 time-domain EM metal detector over a non-magnetic copper pipe target, and a steel artillery shell in horizontal and vertical orientations. Results show that this approximation to a permeable prism has a capability of fitting geometric, conductivity and magnetic parameters at both early and late sample times. The magnetic parameters show strong change from early to late times on the EMI decay curve, indicating that the magnetic properties of the target have non-linear characteristics. It is proposed that these magnetic parameters and the nature of their non-linearity may carry additional discrimination information for distinguishing between intact munitions and scrap in UXO studies.

  8. Diagnostics of the Fermilab Tevatron using an AC dipole

    SciTech Connect

    Miyamoto, Ryoichi

    2008-08-01

    The Fermilab Tevatron is currently the world's highest energy colliding beam facility. Its counter-rotating proton and antiproton beams collide at 2 TeV center-of-mass. Delivery of such intense beam fluxes to experiments has required improved knowledge of the Tevatron's beam optical lattice. An oscillating dipole magnet, referred to as an AC dipole, is one of such a tool to non-destructively assess the optical properties of the synchrotron. We discusses development of an AC dipole system for the Tevatron, a fast-oscillating (f ~ 20 kHz) dipole magnet which can be adiabatically turned on and off to establish sustained coherent oscillations of the beam particles without affecting the transverse emittance. By utilizing an existing magnet and a higher power audio amplifier, the cost of the Tevatron AC dipole system became relatively inexpensive. We discuss corrections which must be applied to the driven oscillation measurements to obtain the proper interpretation of beam optical parameters from AC dipole studies. After successful operations of the Tevatron AC dipole system, AC dipole systems, similar to that in the Tevatron, will be build for the CERN LHC. We present several measurements of linear optical parameters (beta function and phase advance) for the Tevatron, as well as studies of non-linear perturbations from sextupole and octupole elements.

  9. A poroelastic finite element model of the bone-cartilage unit to determine the effects of changes in permeability with osteoarthritis.

    PubMed

    Stender, Michael E; Regueiro, Richard A; Ferguson, Virginia L

    2017-02-01

    The changes experienced in synovial joints with osteoarthritis involve coupled chemical, biological, and mechanical processes. The aim of this study was to investigate the consequences of increasing permeability in articular cartilage (AC), calcified cartilage (CC), subchondral cortical bone (SCB), and subchondral trabecular bone (STB) as observed with osteoarthritis. Two poroelastic finite element models were developed using a depth-dependent anisotropic model of AC with strain-dependent permeability and poroelastic models of calcified tissues (CC, SCB, and STB). The first model simulated a bone-cartilage unit (BCU) in uniaxial unconfined compression, while the second model simulated spherical indentation of the AC surface. Results indicate that the permeability of AC is the primary determinant of the BCU's poromechanical response while the permeability of calcified tissues exerts no appreciable effect on the force-indentation response of the BCU. In spherical indentation simulations with osteoarthritic permeability properties, fluid velocities were larger in magnitude and distributed over a smaller area compared to normal tissues. In vivo, this phenomenon would likely lead to chondrocyte death, tissue remodeling, alterations in joint lubrication, and the progression of osteoarthritis. For osteoarthritic and normal tissue permeability values, fluid flow was predicted to occur across the osteochondral interface. These results help elucidate the consequences of increases in the permeability of the BCU that occur with osteoarthritis. Furthermore, this study may guide future treatments to counteract osteoarthritis.

  10. AC/DC converter

    NASA Astrophysics Data System (ADS)

    Jain, Praveen K.

    1992-08-01

    In a system such as a 20 kHz space station primary electrical power distribution system, power conversion from AC to DC is required. Some of the basic requirements for this conversion are high efficiency, light weight and small volume, regulated output voltage, close to unity input power factor, distortionless input current, soft-starting, low electromagnetic interference, and high reliability. An AC-to-DC converter is disclosed which satisfies the main design objectives of such converters for use in space. The converter of the invention comprises an input transformer, a resonant network, a current controller, a diode rectifier, and an output filter. The input transformer is for connection to a single phase, high frequency, sinusoidal waveform AC voltage source and provides a matching voltage isolating from the AC source. The resonant network converts this voltage to a sinusoidal, high frequency bidirectional current output, which is received by the current controller to provide the desired output current. The diode rectifier is connected in parallel with the current controller to convert the bidirectional current into a unidirectional current output. The output filter is connected to the rectifier to provide an essentially ripple-free, substantially constant voltage DC output.

  11. AC/RF Superconductivity

    SciTech Connect

    Ciovati, Gianluigi

    2015-02-01

    This contribution provides a brief introduction to AC/RF superconductivity, with an emphasis on application to accelerators. The topics covered include the surface impedance of normal conductors and superconductors, the residual resistance, the field dependence of the surface resistance, and the superheating field.

  12. Microwave permeability of composites filled with thin Fe films

    NASA Astrophysics Data System (ADS)

    Iakubov, Igor T.; Lagarkov, Andrey N.; Maklakov, Sergey A.; Osipov, Alexey V.; Rozanov, Konstantin N.; Ryzhikov, Ilya A.; Starostenko, Sergey N.

    2006-05-01

    The microwave permeability of regular composites filled with thin ferromagnetic discs with in-plane anisotropy is studied. The samples are made of patterned, multi-layered Fe films stacked together to comprise a bulk composite. The permeability is measured in the frequency range of 0.1-10 GHz, and is discussed in terms of constraints to the microwave performance of such composites. The technology suggested allows a composite sample to be produced with the permeability of 2.8, and low magnetic loss at frequencies below 1 GHz, the volume fraction of Fe is as low as 0.77%. Such composites can be useful in the design of microwave inductors, miniaturized wideband antennas, etc.

  13. Organic magnetoresistance under resonant ac drive

    NASA Astrophysics Data System (ADS)

    Roundy, R. C.; Raikh, M. E.

    2013-09-01

    Motivated by a recent experiment, we develop a theory of organic magnetoresistance (OMAR) in the presence of a resonant ac drive. To this end, we perform a thorough analysis of the dynamics of ac-driven electron-hole polaron pair in magnetic field, which is a sum of external and random hyperfine fields. Resonant ac drive affects the OMAR by modifying the singlet content of the eigenmodes. This, in turn, leads to the change of recombination rate, and ultimately, to the change of the spin-blocking that controls the current. Our analysis demonstrates that, upon increasing the drive amplitude, the blocking eigenmodes of the triplet type acquire a singlet admixture and become unblocking. Most surprisingly, the opposite process goes in parallel: new blocking modes emerge from nonblocking precursors as the drive increases. These emergent blocking modes are similar to subradiant modes in the Dicke effect. A nontrivial evolution of eigenmodes translates into a nontrivial behavior of OMAR with the amplitude of the ac drive: it is initially linear, then passes through a maximum, drops, and finally saturates.

  14. Platelets can enhance vascular permeability.

    PubMed

    Cloutier, Nathalie; Paré, Alexandre; Farndale, Richard W; Schumacher, H Ralph; Nigrovic, Peter A; Lacroix, Steve; Boilard, Eric

    2012-08-09

    Platelets survey blood vessels, searching for endothelial damage and preventing loss of vascular integrity. However, there are circumstances where vascular permeability increases, suggesting that platelets sometimes fail to fulfill their expected function. Human inflammatory arthritis is associated with tissue edema attributed to enhanced permeability of the synovial microvasculature. Murine studies have suggested that such vascular leak facilitates entry of autoantibodies and may thereby promote joint inflammation. Whereas platelets typically help to promote microvascular integrity, we examined the role of platelets in synovial vascular permeability in murine experimental arthritis. Using an in vivo model of autoimmune arthritis, we confirmed the presence of endothelial gaps in inflamed synovium. Surprisingly, permeability in the inflamed joints was abrogated if the platelets were absent. This effect was mediated by platelet serotonin accumulated via the serotonin transporter and could be antagonized using serotonin-specific reuptake inhibitor antidepressants. As opposed to the conventional role of platelets to microvascular leakage, this demonstration that platelets are capable of amplifying and maintaining permeability adds to the rapidly growing list of unexpected functions for platelets.

  15. Pyrotechnic deflagration velocity and permeability

    SciTech Connect

    Begeal, D R; Stanton, P L

    1982-01-01

    Particle size, porosity, and permeability of the reactive material have long been considered to be important factors in propellant burning rates and the deflagration-to-detonation transition in explosives. It is reasonable to assume that these same parameters will also affect the deflagration velocity of pyrotechnics. This report describes an experimental program that addresses the permeability of porous solids (particulate beds), in terms of particle size and porosity, and the relationship between permeability and the behavior of pyrotechnics and explosives. The experimental techniques used to acquire permeability data and to characterize the pyrotechnic burning are discussed. Preliminary data have been obtained on the burning characteristics of titanium hydride/potassium perchlorate (THKP) and boron/calcium chromate (BCCR). With THKP, the velocity of a pressure wave (from hot product gases) in the unburned region shows unsteady behavior which is related to the initial porosity or permeability. Simultaneous measurements with pressure gauges and ion gauges reveal that the pressure wave precedes the burn front. Steady burning of BCCR was observed with pressure gauge diagnostics and with a microwave interferometry technique.

  16. Total AC loss study of 2G HTS coils for fully HTS machine applications

    NASA Astrophysics Data System (ADS)

    Zhang, Min; Yuan, Weijia; Kvitkovic, Jozef; Pamidi, Sastry

    2015-11-01

    The application of HTS coils for fully HTS machines has become a new research focus. In the stator of an electrical machine, HTS coils are subjected to a combination of an AC applied current and AC external magnetic field. There is a phase shift between the AC current and AC magnetic field. In order to understand and estimate the total AC loss of HTS coils for electrical machines, we designed and performed a calorimetric measurement for a 2G HTS racetrack coil. Our measurement indicates that the total AC loss is greatly influenced by the phase shift between the applied current and the external magnetic field when the magnetic field is perpendicular to the tape surface. When the applied current and the external magnetic field are in phase, the total AC loss is the highest. When there is a 90 degree phase difference, the total AC loss is the lowest. In order to explain this phenomenon, we employ H formulation and finite element method to model the 2G HTS racetrack coil. Our calculation agrees well with experimental measurements. Two parameters are defined to describe the modulation of the total AC loss in terms of phase difference. The calculation further reveals that the influence of phase difference varies with magnetic field direction. The greatest influence of phase difference is in the perpendicular direction. The study provides key information for large-scale 2G HTS applications, e.g. fully HTS machines and superconducting magnetic energy storage, where the total AC loss subjected to both applied currents and external magnetic fields is a critical parameter for the design.

  17. Magnetic resonance in ferromagnetic films, multilayers and nanoparticle composites

    NASA Astrophysics Data System (ADS)

    Noginova, Natalia; Bates, Brittany; Greene, Nicole

    2014-03-01

    Incorporation of magnetic materials into metamaterial systems provides an opportunity to tune microwave permeability with external magnetic field. We studied magnetically dependent microwave properties of polymer composites with iron oxide nanoparticles, ferromagnetic films and ferromagnetic/dielectric multilayers. We show that the permeability of such systems can be magnetically tuned from positive to negative values in the range of ferromagnetic resonance, strongly affecting wave propagation. Strong changes in mu-metal permeability in low field range provides an additional possibility of tuning.

  18. Controlling ferrofluid permeability across the blood–brain barrier model.

    PubMed

    Shi, Di; Sun, Linlin; Mi, Gujie; Sheikh, Lubna; Bhattacharya, Soumya; Nayar, Suprabha; Webster, Thomas J

    2014-02-21

    In the present study, an in vitro blood–brain barrier model was developed using murine brain endothelioma cells (b.End3 cells). Confirmation of the blood–brain barrier model was completed by examining the permeability of FITCDextran at increasing exposure times up to 96 h in serum-free medium and comparing such values with values from the literature. After such confirmation, the permeability of five novel ferrofluid (FF) nanoparticle samples, GGB (ferrofluids synthesized using glycine, glutamic acid and BSA), GGC (glycine, glutamic acid and collagen), GGP (glycine, glutamic acid and PVA), BPC (BSA, PEG and collagen) and CPB (collagen, PVA and BSA), was determined using this blood–brain barrier model. All of the five FF samples were characterized by zeta potential to determine their charge as well as TEM and dynamic light scattering for determining their hydrodynamic diameter. Results showed that FF coated with collagen passed more easily through the blood–brain barrier than FF coated with glycine and glutamic acid based on an increase of 4.5% in permeability. Through such experiments, diverse magnetic nanomaterials (such as FF) were identified for: (1) MRI use since they were less permeable to penetrate the blood–brain barrier to avoid neural tissue toxicity (e.g. GGB) or (2) brain drug delivery since they were more permeable to the blood–brain barrier (e.g. CPB).

  19. Controlling ferrofluid permeability across the blood-brain barrier model

    NASA Astrophysics Data System (ADS)

    Shi, Di; Sun, Linlin; Mi, Gujie; Sheikh, Lubna; Bhattacharya, Soumya; Nayar, Suprabha; Webster, Thomas J.

    2014-02-01

    In the present study, an in vitro blood-brain barrier model was developed using murine brain endothelioma cells (b.End3 cells). Confirmation of the blood-brain barrier model was completed by examining the permeability of FITC-Dextran at increasing exposure times up to 96 h in serum-free medium and comparing such values with values from the literature. After such confirmation, the permeability of five novel ferrofluid (FF) nanoparticle samples, GGB (ferrofluids synthesized using glycine, glutamic acid and BSA), GGC (glycine, glutamic acid and collagen), GGP (glycine, glutamic acid and PVA), BPC (BSA, PEG and collagen) and CPB (collagen, PVA and BSA), was determined using this blood-brain barrier model. All of the five FF samples were characterized by zeta potential to determine their charge as well as TEM and dynamic light scattering for determining their hydrodynamic diameter. Results showed that FF coated with collagen passed more easily through the blood-brain barrier than FF coated with glycine and glutamic acid based on an increase of 4.5% in permeability. Through such experiments, diverse magnetic nanomaterials (such as FF) were identified for: (1) MRI use since they were less permeable to penetrate the blood-brain barrier to avoid neural tissue toxicity (e.g. GGB) or (2) brain drug delivery since they were more permeable to the blood-brain barrier (e.g. CPB).

  20. Permeability enhancement by shock cooling

    NASA Astrophysics Data System (ADS)

    Griffiths, Luke; Heap, Michael; Reuschlé, Thierry; Baud, Patrick; Schmittbuhl, Jean

    2015-04-01

    The permeability of an efficient reservoir, e.g. a geothermal reservoir, should be sufficient to permit the circulation of fluids. Generally speaking, permeability decreases over the life cycle of the geothermal system. As a result, is usually necessary to artificially maintain and enhance the natural permeability of these systems. One of the methods of enhancement -- studied here -- is thermal stimulation (injecting cold water at low pressure). This goal of this method is to encourage new thermal cracks within the reservoir host rocks, thereby increasing reservoir permeability. To investigate the development of thermal microcracking in the laboratory we selected two granites: a fine-grained (Garibaldi Grey granite, grain size = 0.5 mm) and a course-grained granite (Lanhelin granite, grain size = 2 mm). Both granites have an initial porosity of about 1%. Our samples were heated to a range of temperatures (100-1000 °C) and were either cooled slowly (1 °C/min) or shock cooled (100 °C/s). A systematic microstructural (2D crack area density, using standard stereological techniques, and 3D BET specific surface area measurements) and rock physical property (porosity, P-wave velocity, uniaxial compressive strength, and permeability) analysis was undertaken to understand the influence of slow and shock cooling on our reservoir granites. Microstructurally, we observe that the 2D crack surface area per unit volume and the specific surface area increase as a result of thermal stressing, and, for the same maximum temperature, crack surface area is higher in the shock cooled samples. This observation is echoed by our rock physical property measurements: we see greater changes for the shock cooled samples. We can conclude that shock cooling is an extremely efficient method of generating thermal microcracks and modifying rock physical properties. Our study highlights that thermal treatments are likely to be an efficient method for the "matrix" permeability enhancement of

  1. Protection against malonate-induced ischemic brain injury in rat by a cell-permeable peptidic c-Jun N-terminal kinase inhibitor, (L)-HIV-TAT48-57-PP-JBD20, observed by the apparent diffusion coefficient mapping magnetic resonance imaging method.

    PubMed

    Asanuma, Taketoshi; Inanami, Osamu; Tabu, Kouichi; Waki, Kenji; Kon, Yasuhiro; Kuwabara, Mikinori

    2004-04-08

    The present experiments were carried out to provide direct in vivo evidence for the involvement of c-Jun N-terminal kinase (JNK) in the induction of ischemic brain injury. Malonate, which produces lesions similar to those of focal ischemia-reperfusion by a reversible inhibition of succinate dehydrogenase in mitochondria, was injected into the left striatum in the rat brain without or with the simultaneous injection of a cell permeable peptidic JNK inhibitor, (L)-HIV-TAT48-57-PP-JBD20. Two regions of malonate-induced brain injury were visualized as a hyperintense region with surrounding hypointense regions by apparent diffusion coefficient mapping magnetic resonance imaging. The JNK inhibitor significantly counteracted both hyper- and hypointense regions at the early stage of brain injury. Histological examination clarified that the inhibitor suppressed the induction of coagulation necrosis and spongy degeneration at early and late stages.

  2. Turbulent drag reduction by permeable coatings

    NASA Astrophysics Data System (ADS)

    Garcia-Mayoral, Ricardo; Abderrahaman-Elena, Nabil

    2015-11-01

    We present an assessment of permeable coatings as a form of passive drag reduction, proposing a simplified model to quantify the effect of the coating thickness and permeability. To reduce skin friction, the porous layer must be preferentially permeable in the streamwise direction, so that a slip effect is produced. For small permeability, the controlling parameter is the difference between streamwise and spanwise permeability lengths, scaled in viscous units, √{Kx+}-√{Kz+}. In this regime, the reduction in drag is proportional to that difference. However, the proportional performance eventually breaks down for larger permeabilities. A degradation mechanism is investigated, common to other obstructed surfaces in general and permeable substrates in particular, which depends critically on the geometric mean of the streamwise and wall-normal permeabilities, √{Kx+ Ky+}. For a streamwise-to-cross-plane permeability ratio of order Kx+/Ky+ = Kx+/Kz+ 10 -100, the model predicts a maximum drag reduction of order 15-25%.

  3. DESIGN OF AN AC-DIPOLE FOR USE IN RHIC.

    SciTech Connect

    PARKER,B.; BAI,M.; JAIN,A.; MCINTYRE,G.; METH,M.; PEGGS,S.; ROSER,T.; SANDERS,R.; TRBOJEVIC,D.

    1999-03-29

    We present two options for implementing a pair of AC-dipoles in RHIC for spin flipping, measuring linear optical functions and nonlinear diagnostics. AC-dipoles are magnets that can be adiabatically excited and de-excited with a continuous sine-wave in order to coherently move circulating beam out to large betatron amplitudes without incurring emittance blow up [1]. The AGS already uses a similar device for getting polarized proton beams through depolarizing resonances [2]. By placing the magnets in the IP4 common beam region, two AC-dipoles are sufficient to excite both horizontal and vertical motion in both RHIC rings. While we initially investigated an iron-dominated magnet design using available steel tape cores; we now favor a new air coil plus ferrite design featuring mechanical frequency tuning, in order to best match available resources to demanding frequency sweeping requirements. Both magnet designs are presented here along with model magnet test results. The challenge is to make AC-dipoles available for year 2000 RHIC running.

  4. Superconducting magnet and fabrication method

    NASA Technical Reports Server (NTRS)

    Israelsson, Ulf E. (Inventor); Strayer, Donald M. (Inventor)

    1994-01-01

    A method of trapping a field in a block of superconductor material, includes providing (i) a block of material defining a bore, (ii) a high permeability core within the bore that defines a low reluctance path through the bore, (iii) a high permeability external structure on the exterior of the block of material that defines a low reluctance path between opposite ends of the core, and (iv) an electromagnet configured to apply a magnetic field around the high permeability core. The method proceeds by energizing the electromagnet to produce an applied magnetic field around the high permeability core, cooling the block of material sufficiently to render the block of material superconducting, de-energizing the electromagnet to result in a trapped magnetic field, and at least partially removing the low reluctance path defined by the core and the external structure in order to increase the magnetic flux density of the trapped magnetic field.

  5. Rigid gas permeable extended wear.

    PubMed

    Maehara, J R; Kastl, P R

    1994-04-01

    We have reviewed the pertinent literature on rigid gas permeable (RGP) extended wear contact lenses, and we discuss the benefits and adverse reactions of this contact lens modality, drawing conclusions from reviewed studies. We suggest parameters for success with these lenses and guidelines for the prevention of adverse reactions.

  6. On the Huygens principle for bianisotropic mediums with symmetric permittivity and permeability dyadics

    NASA Astrophysics Data System (ADS)

    Faryad, Muhammad; Lakhtakia, Akhlesh

    2017-02-01

    Mathematical statements of the Huygens principle relate the electric and magnetic field phasors at an arbitrary location in a source-free region enclosed by a surface to the tangential components of the electric and magnetic field phasors over that surface, via the dyadic Green functions applicable to the linear homogeneous medium occupying that region. We have mathematically formulated the Huygens principle for the electric and magnetic field phasors when the permittivity and permeability dyadics of the medium are symmetric, the symmetric parts of the two magnetoelectric dyadics of the medium are negative of each other, and both magnetoelectric dyadics also contain anti-symmetric terms. We have also formulated the Huygens principle for the electric (resp. magnetic) field phasor in a medium whose permittivity (resp. permeability) is scalar, the permeability (resp. permittivity) is symmetric, the symmetric parts of the two magnetoelectric dyadics reduce to dissimilar scalars, and anti-symmetric parts of the two magnetoelectric dyadics are identical.

  7. High membrane permeability for melatonin

    PubMed Central

    Yu, Haijie; Dickson, Eamonn J.; Jung, Seung-Ryoung; Koh, Duk-Su

    2016-01-01

    The pineal gland, an endocrine organ in the brain, synthesizes and secretes the circulating night hormone melatonin throughout the night. The literature states that this hormone is secreted by simple diffusion across the pinealocyte plasma membrane, but a direct quantitative measurement of membrane permeability has not been made. Experiments were designed to compare the cell membrane permeability to three indoleamines: melatonin and its precursors N-acetylserotonin (NAS) and serotonin (5-HT). The three experimental approaches were (1) to measure the concentration of effluxing indoleamines amperometrically in the bath while cells were being dialyzed internally by a patch pipette, (2) to measure the rise of intracellular indoleamine fluorescence as the compound was perfused in the bath, and (3) to measure the rate of quenching of intracellular fura-2 dye fluorescence as indoleamines were perfused in the bath. These measures showed that permeabilities of melatonin and NAS are high (both are uncharged molecules), whereas that for 5-HT (mostly charged) is much lower. Comparisons were made with predictions of solubility-diffusion theory and compounds of known permeability, and a diffusion model was made to simulate all of the measurements. In short, extracellular melatonin equilibrates with the cytoplasm in 3.5 s, has a membrane permeability of ∼1.7 µm/s, and could not be retained in secretory vesicles. Thus, it and NAS will be “secreted” from pineal cells by membrane diffusion. Circumstances are suggested when 5-HT and possibly catecholamines may also appear in the extracellular space passively by membrane diffusion. PMID:26712850

  8. AC Zeeman potentials for atom chip-based ultracold atoms

    NASA Astrophysics Data System (ADS)

    Fancher, Charles; Pyle, Andrew; Ziltz, Austin; Aubin, Seth

    2015-05-01

    We present experimental and theoretical progress on using the AC Zeeman force produced by microwave magnetic near-fields from an atom chip to manipulate and eventually trap ultracold atoms. These AC Zeeman potentials are inherently spin-dependent and can be used to apply qualitatively different potentials to different spin states simultaneously. Furthermore, AC Zeeman traps are compatible with the large DC magnetic fields necessary for accessing Feshbach resonances. Applications include spin-dependent trapped atom interferometry and experiments in 1D many-body physics. Initial experiments and results are geared towards observing the bipolar detuning-dependent nature of the AC Zeeman force at 6.8 GHz with ultracold 87Rb atoms trapped in the vicinity of an atom chip. Experimental work is also underway towards working with potassium isotopes at frequencies of 1 GHz and below. Theoretical work is focused on atom chip designs for AC Zeeman traps produced by magnetic near-fields, while also incorporating the effect of the related electric near-fields. Electromagnetic simulations of atom chip circuits are used for mapping microwave propagation in on-chip transmission line structures, accounting for the skin effect, and guiding impedance matching.

  9. Quantifying Evaporation in a Permeable Pavement System

    EPA Science Inventory

    Studies quantifying evaporation from permeable pavement systems are limited to a few laboratory studies and one field application. This research quantifies evaporation for a larger-scale field application by measuring the water balance from lined permeable pavement sections. Th...

  10. Drug permeability prediction using PMF method.

    PubMed

    Meng, Fancui; Xu, Weiren

    2013-03-01

    Drug permeability determines the oral availability of drugs via cellular membranes. Poor permeability makes a drug unsuitable for further development. The permeability may be estimated as the free energy change that the drug should overcome through crossing membrane. In this paper the drug permeability was simulated using molecular dynamics method and the potential energy profile was calculated with potential of mean force (PMF) method. The membrane was simulated using DPPC bilayer and three drugs with different permeability were tested. PMF studies on these three drugs show that doxorubicin (low permeability) should pass higher free energy barrier from water to DPPC bilayer center while ibuprofen (high permeability) has a lower energy barrier. Our calculation indicates that the simulation model we built is suitable to predict drug permeability.

  11. Permeable Pavement Research - Edison, New Jersey

    EPA Science Inventory

    This presentation provides the background and summary of results collected at the permeable pavement parking lot monitored at the EPA facility in Edison, NJ. This parking lot is surfaced with permeable interlocking concrete pavers (PICP), pervious concrete, and porous asphalt. ...

  12. Power reduction in nanomagnet logic using high-permeability dielectrics

    NASA Astrophysics Data System (ADS)

    Li, Peng; Csaba, Gyorgy; Niemier, Michael; Sharon Hu, X.; Nahas, Joe; Porod, Wolfgang; Bernstein, Gary H.

    2013-05-01

    In nanomagnet logic (NML), tens-of-mT fields are required to initiate the ordering of nanomagnets, and clock them into their computational ground state. This work investigates material-based approaches that are being used to reduce the nulling clock field. As test cases, arrays of both standalone and coupled magnets are covered with enhanced-permeability dielectric (EPD) films. Experimental results demonstrate that EPDs can reduce the fields required to saturate standalone magnets along the hard-axis by 60%, and coupled magnets by 75%. Experiments show that the remanent magnetization of a nanomagnet array is unchanged after being coated with EPDs, demonstrating that no undesired remanence is added to the NML system. The 75% reduction in switching field translates to a 94% reduction in energy dissipation due to reduced Joule-heating of field-generating wires.

  13. Novel additives to retard permeable flow

    SciTech Connect

    Golombok, Michael; Crane, Carel; Ineke, Erik; Welling, Marco; Harris, Jon

    2008-09-15

    Low concentrations of surfactant and cosolute in water, can selectively retard permeable flow in high permeability rocks compared to low permeability ones. This represents a way forward for more efficient areal sweep efficiency when water flooding a reservoir during improved oil recovery. (author)

  14. Review of Hydrogen Isotope Permeability Through Materials

    SciTech Connect

    Steward, S. A.

    1983-08-15

    This report is the first part of a comprehensive summary of the literature on hydrogen isotope permeability through materials that do not readily form hydrides. While we mainly focus on pure metals with low permeabilities because of their importance to tritium containment, we also give data on higher-permeability materials such as iron, nickel, steels, and glasses.

  15. Structure/Permeability Relationships Of Polyimide Membranes

    NASA Technical Reports Server (NTRS)

    St. Clair, A. K.; Yamamoto, H.; Mi, Y.; Stern, S. A.

    1995-01-01

    Report describes experimental study of permeabilities, by each of five gases, of membranes made of four different polyimides. Conducted to gain understanding of effects of molecular structures of membranes on permeabilities and to assess potential for exploitation of selective permeability in gas-separation processes. Gases used: H2, O2, N2, CO2, and CH4.

  16. AC resistance measuring instrument

    DOEpatents

    Hof, P.J.

    1983-10-04

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.

  17. AC Resistance measuring instrument

    DOEpatents

    Hof, Peter J.

    1983-01-01

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument.

  18. AC Optimal Power Flow

    SciTech Connect

    2016-10-04

    In this work, we have implemented and developed the simulation software to implement the mathematical model of an AC Optimal Power Flow (OPF) problem. The objective function is to minimize the total cost of generation subject to constraints of node power balance (both real and reactive) and line power flow limits (MW, MVAr, and MVA). We have currently implemented the polar coordinate version of the problem. In the present work, we have used the optimization solver, Knitro (proprietary and not included in this software) to solve the problem and we have kept option for both the native numerical derivative evaluation (working satisfactorily now) as well as for analytical formulas corresponding to the derivatives being provided to Knitro (currently, in the debugging stage). Since the AC OPF is a highly non-convex optimization problem, we have also kept the option for a multistart solution. All of these can be decided by the user during run-time in an interactive manner. The software has been developed in C++ programming language, running with GCC compiler on a Linux machine. We have tested for satisfactory results against Matpower for the IEEE 14 bus system.

  19. Nexal membrane permeability to anions

    PubMed Central

    1978-01-01

    The permeability of the septa of the earthworm in the median axon has been calculated for the anions fluorescein and its halogen derivatives. The values ranged from 5.4 X 10(-5) to 4 X 10(-6) cm/s. Previously, the septa had been shown to contain nexuses. By using freeze-fracture material, the surface area of nexus on the septal membranes was determined to be 4.5%, very similar to the percentage of nexus in the intercalated disk of mammalian myocardium. Plasma membrane permeability to these dyes was also calculated and shown to be much less than that of the septal membranes. In addition, an estimate of cytoplasmic binding for each dye was made, and most dyes showed little or no binding with the exception of aminofluorescein. PMID:702107

  20. THE GRADIENT OF VASCULAR PERMEABILITY

    PubMed Central

    Smith, Frederick; Rous, Peyton

    1931-01-01

    A mounting gradient of permeability exists along the capillaries of frog muscle. In chicken muscle on the other hand none has been demonstrated; but the close-knit vascularization is arranged in duplicate in such manner that the blood runs in opposite directions through the capillaries of nearly adjacent fibres. In a flight muscle of the pigeon there exists in addition to this artifice what appears to be a special collecting system of venous capillaries. In the mammalian diaphragm indications of such a system are also to be found, and a gradient of capillary permeability like that in the other skeletal muscles is probably present. These vascular conditions are briefly considered in terms of function. PMID:19869836

  1. Experimental Volcanology: Fragmentation and Permeability

    NASA Astrophysics Data System (ADS)

    Spieler, O.

    2005-12-01

    An increasing number of scientists design new experiments to analyse processes that control the dynamics of explosive eruptions. There research is mostly coupled to numerical models and aims toward its controlling parameters. The fragmentation process, its threshold and the speed of the fragmentation wave as well as the energy consumed by the fragmentation are some hot spots of the experimental volcanology. Analysing the fragmentation behaviour of volcaniclastics as close to the natural system as possible, we found a number of physical constrains. Identifying the porosity as determining factor of the threshold, we realised that neither threshold nor the speed of the fragmentation process are solely controlled by the rock density. The later results of the shock tube type apparatus lead to the analysis of the specific surface area and permeability as direct links to textural features. Permeability analysis performed in a modified shock tube type apparatus, show two clear, distinct trends for dome rock and pyroclastic samples. The specific surface determined by Argon sorbtion (BET) as well as textural features of pumices from Campi Flegrei, Montserrat and Krakatoa (1883) give in contrary evidence of a more complex story. Large spherical, or ellipsoidal bubbles around fractured crystals prove that the high permeability of the pumice has partially developed after the fixing of the bubble size distribution. This puts up the question, if permeability measurements on pyroclastic samples reveal relevant numbers! The surface tension controlled 'self sealing' behaviour of surfaces from foaming obsidian hinders in situ measurements. Close textural investigations will have to clarify how the 'post process' samples deviate from the syneruptive conduit filling.

  2. Identification of /sup 233/Ac

    SciTech Connect

    Chu, Y.Y.; Zhou, M.L.

    1983-09-01

    We report in this paper identification of the new isotope /sup 233/Ac. Uranium targets were irradiated with 28 GeV protons; after rapid retrieval of the target and separation of actinium from thorium, /sup 233/Ac was allowed to decay into the known /sup 233/Th daughter. Exhaustive chemical purification was employed to permit the identification of /sup 233/Th via its characteristic ..gamma.. radiations. The half-life derived for /sup 233/Ac from several experiments is 2.3 +- 0.3 min. The production cross section for /sup 233/Ac is 100 ..mu..b.

  3. Giant magnetoimpedance and permeability change in La 2/3Sr 1/3MnO 3 manganite under low fields

    NASA Astrophysics Data System (ADS)

    Hu, Jifan; Qin, Hongwei; Wang, Yifei; Li, Bo

    2010-11-01

    We demonstrated that La 2/3Sr 1/3MnO 3 sintered manganite could exhibit a magnetoreactance Δ X/ X0 of -25.5% at 100 kHz, a giant magnetoimpedance Δ Z/ Z0 of -20% at 1-2 MHz and a giant AC magnetoresistance Δ R/ R0 of -39.3% at 5 MHz under a very low field of 300 Oe at room temperature, whereas the DC magnetoresistance Δ ρ/ ρ0 was -3.95% under H=10 kOe and only about -0.18% under H=300 Oe. Large field-induced change of real and imaginary circular permeabilities ( Δμ/ μ(0) and Δμ/ μ(0)) were obtained for La 2/3Sr 1/3MnO 3 sintered manganite. The giant magnetoreactance (giant magneto-inductive effect) at very low frequencies originates from the field induced change of transverse permeability. At 100 kHz under H=300 Oe, La 2/3Sr 1/3MnO 3 sintered manganite has Δμ/ μ(0)=-25.8% and Δμ/ μ(0)=-10.9%. The values of Δ R/ R0 and Δ Z/ Z0 are very small under 300 Oe at 100 kHz. The giant magnetoimpedance at high frequencies mainly originates from the large transverse permeability change induced by DC magnetic fields, via the penetration depth. Under H=300 Oe, La 2/3Sr 1/3MnO 3 sintered manganite presents values of Δμ/ μ(0)=-24.9%, Δμ/ μ(0)=-49.8% at 1 MHz, and Δμ/ μ(0)=-21.2%, Δμ/ μ(0)=-58.2% at 5 MHz.

  4. Syntheses, structures, and magnetic properties of acetato- and diphenolato-bridged 3d-4f binuclear complexes [M(3-MeOsaltn)(MeOH)x(ac)Ln(hfac)2] (M = Zn(II), Cu(II), Ni(II), Co(II); Ln = La(III), Gd(III), Tb(III), Dy(III); 3-MeOsaltn = N,N'-bis(3-methoxy-2-oxybenzylidene)-1,3-propanediaminato; ac = acetato; hfac = hexafluoroacetylacetonato; x = 0 or 1).

    PubMed

    Towatari, Masaaki; Nishi, Koshiro; Fujinami, Takeshi; Matsumoto, Naohide; Sunatsuki, Yukinari; Kojima, Masaaki; Mochida, Naotaka; Ishida, Takayuki; Re, Nazzareno; Mrozinski, Jerzy

    2013-05-20

    A series of 3d-4f binuclear complexes, [M(3-MeOsaltn)(MeOH)x(ac)Ln(hfac)2] (x = 0 for M = Cu(II), Zn(II); x = 1 for M = Co(II), Ni(II); Ln = Gd(III), Tb(III), Dy(III), La(III)), have been synthesized and characterized, where 3-MeOsaltn, ac, and hfac denote N,N'-bis(3-methoxy-2-oxybenzylidene)-1,3-propanediaminato, acetato, and hexafluoroacetylacetonato, respectively. The X-ray analyses demonstrated that all the complexes have an acetato- and diphenolato-bridged M(II)-Ln(III) binuclear structure. The Cu(II)-Ln(III) and Zn(II)-Ln(III) complexes are crystallized in an isomorphous triclinic space group P1, where the Cu(II) or Zn(II) ion has square pyramidal coordination geometry with N2O2 donor atoms of 3-MeOsaltn at the equatorial coordination sites and one oxygen atom of the bridging acetato ion at the axial site. The Co(II)-Ln(III) and Ni(II)-Ln(III) complexes are crystallized in an isomorphous monoclinic space group P2(1)/c, where the Co(II) or Ni(II) ion at the high-spin state has an octahedral coordination environment with N2O2 donor atoms of 3-MeOsaltn at the equatorial sites, and one oxygen atom of the bridged acetato and a methanol oxygen atom at the two axial sites. Each Ln(III) ion for all the complexes is coordinated by four oxygen atoms of two phenolato and two methoxy oxygen atoms of "ligand-complex" M(3-MeOsaltn), four oxygen atoms of two hfac(-), and one oxygen atom of the bridging acetato ion; thus, the coordination number is nine. The temperature dependent magnetic susceptibilities from 1.9 to 300 K and the field-dependent magnetization up to 5 T at 1.9 K were measured. Due to the important orbital contributions of the Ln(III) (Tb(III), Dy(III)) and to a lesser extent the M(II) (Ni(II), Co(II)) components, the magnetic interaction between M(II) and Ln(III) ions were investigated by an empirical approach based on a comparison of the magnetic properties of the M(II)-Ln(III), Zn(II)-Ln(III), and M(II)-La(III) complexes. The differences of χ(M)T and M

  5. Magnetic transit-time flowmeter

    DOEpatents

    Forster, George A.

    1976-07-06

    The flow rate of a conducting fluid in a stream is determined by disposing two permanent-magnet flowmeters in the stream, one downstream of the other. Flow of the conducting fluid causes the generation of both d-c and a-c electrical signals, the a-c comprising flow noise. Measurement of the time delay between similarities in the a-c signals by cross-correlation methods provides a measure of the rate of flow of the fluid.

  6. Digital ac monitor

    DOEpatents

    Hart, George W.; Kern, Jr., Edward C.

    1987-06-09

    An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer.

  7. Digital ac monitor

    DOEpatents

    Hart, G.W.; Kern, E.C. Jr.

    1987-06-09

    An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer. 24 figs.

  8. Cooling Floor AC Systems

    NASA Astrophysics Data System (ADS)

    Jun, Lu; Hao, Ding; Hong, Zhang; Ce, Gao Dian

    The present HVAC equipments for the residential buildings in the Hot-summer-and-Cold-winter climate region are still at a high energy consuming level. So that the high efficiency HVAC system is an urgently need for achieving the preset government energy saving goal. With its advantage of highly sanitary, highly comfortable and uniform of temperature field, the hot-water resource floor radiation heating system has been widely accepted. This paper has put forward a new way in air-conditioning, which combines the fresh-air supply unit and such floor radiation system for the dehumidification and cooling in summer or heating in winter. By analyze its advantages and limitations, we found that this so called Cooling/ Heating Floor AC System can improve the IAQ of residential building while keep high efficiency quality. We also recommend a methodology for the HVAC system designing, which will ensure the reduction of energy cost of users.

  9. Influence of the carbon substitution on the critical current density and AC losses in MgB2 single crystals

    NASA Astrophysics Data System (ADS)

    Ciszek, M.; Rogacki, K.; Oganisian, K.; Zhigadlo, N. D.; Karpinski, J.

    2010-12-01

    The DC magnetization and AC complex magnetic susceptibilities were measured for MgB2 single crystals, unsubstituted and carbon substituted with the composition of Mg(B0.94C0.05)2. The measurements were performed in AC and DC magnetic fields oriented parallel to the c-axis of the crystals. From the DC magnetization loops and the AC susceptibility measurements, critical current densities ( J c were derived as a function of temperature and the DC and AC magnetic fields. Results show that the substitution with carbon decreases J c ) at low magnetic fields, opposite to the well known effect of an increase of J c at higher fields. AC magnetic losses were derived from the AC susceptibility data as a function of amplitude and the DC bias magnetic field. The AC losses were determined for temperatures of 0.6 and 0.7 of the transition temperature T c , so close to the boiling points of LH2 and LNe, potential cooling media for magnesium diboride based composites. The results are analyzed and discussed in the context of the critical state model.

  10. Study of Magnetic Domain Dynamics Using Nonlinear Magnetic Responses: Magnetic Diagnostics of the Itinerant Magnet MnP

    NASA Astrophysics Data System (ADS)

    Mito, Masaki; Matsui, Hideaki; Tsuruta, Kazuki; Deguchi, Hiroyuki; Kishine, Jun-ichiro; Inoue, Katsuya; Kousaka, Yusuke; Yano, Shin-ichiro; Nakao, Yuya; Akimitsu, Jun

    2015-10-01

    The nonlinear and linear magnetic responses to an ac magnetic field H are useful for the study of the magnetic dynamics of both magnetic domains and their constituent spins. In particular, the third-harmonic magnetic response M3ω reflects the dynamics of magnetic domains. Furthermore, by considering the ac magnetic response as a function of H, we can evaluate the degree of magnetic nonlinearity, which is closely related to M3ω. In this study, a series of approaches was used to examine the itinerant magnet MnP, in which both ferromagnetic and helical phases are present. On the basis of this investigation, we systematize the diagnostic approach to evaluating nonlinearity in magnetic responses.

  11. Permeability evolution of shale during spontaneous imbibition

    DOE PAGES

    Chakraborty, N.; Karpyn, Z. T.; Liu, S.; ...

    2017-01-05

    Shales have small pore and throat sizes ranging from nano to micron scales, low porosity and limited permeability. The poor permeability and complex pore connectivity of shales pose technical challenges to (a) understanding flow and transport mechanisms in such systems and, (b) in predicting permeability changes under dynamic saturation conditions. This paper presents quantitative experimental evidence of the migration of water through a generic shale core plug using micro CT imaging. In addition, in-situ measurements of gas permeability were performed during counter-current spontaneous imbibition of water in nano-darcy permeability Marcellus and Haynesville core plugs. It was seen that water blocksmore » severely reduced the effective permeability of the core plugs, leading to losses of up to 99.5% of the initial permeability in experiments lasting 30 days. There was also evidence of clay swelling which further hindered gas flow. When results from this study were compared with similar counter-current gas permeability experiments reported in the literature, the initial (base) permeability of the rock was found to be a key factor in determining the time evolution of effective gas permeability during spontaneous imbibition. With time, a recovery of effective permeability was seen in the higher permeability rocks, while becoming progressively detrimental and irreversible in tighter rocks. Finally, these results suggest that matrix permeability of ultra-tight rocks is susceptible to water damage following hydraulic fracturing stimulation and, while shut-in/soaking time helps clearing-up fractures from resident fluid, its effect on the adjacent matrix permeability could be detrimental.« less

  12. Modifications of the magnetic properties of ferrites by swift heavy ion irradiations

    SciTech Connect

    Costantini, Jean-Marc; Studer, Francis; Peuzin, Jean-Claude

    2001-07-01

    Single crystal plates of ferrimagnetic yttrium iron garnet (111)-YIG:Si (Y{sub 3}Fe{sub 4.94}Si{sub 0.06}O{sub 12}) and barium hexaferrite (00.1)-BaM (BaFe{sub 12}O{sub 19}) or (00.1)-BaM:Co,Ti (BaFe{sub 9.1}Co{sub 1.4}Ti{sub 1.5}O{sub 19}) are irradiated with swift heavy ions (3.8 GeV {sup 129}Xe or 6.0 GeV {sup 208}Pb) in the electronic slowing down regime, above the threshold ({approximately}20 keV nm{minus}1) of formation of continuous and homogeneous cylindrical amorphous tracks. The modifications of the magnetic properties are studied by {sup 57}Fe Moessbauer spectroscopy and ac magnetic permeability measurements versus ion fluence. In the doped crystals having a planar magnetic anisotropy (YIG:Si and BaM:Co,Ti), the room-temperature Moessbauer spectra show that the magnetization is flipped perpendicularly to the sample plane at a critical amorphous fraction around 30% in both compounds. This corresponds to a 90% drop of the measured in-plane magnetic permeability. No such effect is seen in the undoped BaM samples with the axial [00.1] anisotropy. These data are interpreted by a magnetomechanical effect generated by the stress field induced by the amorphous tracks in the sample plane which flips the magnetization along the track-axis direction when the stress-induced anisotropy constant surpasses the pristine crystal anisotropy constant at the critical amorphous fraction. In the case of YIG:Si single crystal, a track-induced anisotropy field around 0.1 T is deduced from the Moessbauer spectra under a magnetic field applied in the sample (111) plane which rotates the magnetization back to the easy {l_angle}111{r_angle} magnetization axis lying near the sample (111) plane in a reversible manner. The magnetic ordering of amorphous YIG:Si below 70 K is also studied by Moessbauer spectroscopy under high magnetic field (5 T). A two-dimensional Bruggeman model used for the calculation of the permeability of the crystal+amorphous track composites yields track

  13. Update on bedside ultrasound (US) diagnosis of acute cholecystitis (AC).

    PubMed

    Zenobii, Maria Francesca; Accogli, Esterita; Domanico, Andrea; Arienti, Vincenzo

    2016-03-01

    Acute cholecystitis (AC) represents a principal cause of morbidity worldwide and is one of the most frequent reasons for hospitalization due to gastroenteric tract diseases. AC should be suspected in presence of clinical signs and of gallstones on an imaging study. Upper abdominal US represents the first diagnostic imaging step in the case of suspected AC. Computed tomography (CT) with intravenous contrast (IV) or magnetic resonance imaging (MRI) with gadolinium contrast and technetium hepatobiliary iminodiacetic acid (Tc-HIDA) can be employed to exclude complications. US examination should be performed with right subcostal oblique, with longitudinal and intercostal scans. Normal gallbladder US findings and AC major and minor US signs are described. Polyps, sludge and gallbladder wall thickening represent the more frequent pitfalls and they must be differentiated from stones, duodenal artifacts and many other non-inflammatory conditions that cause wall thickening, respectively. By means of bedside ultrasound, the finding of gallstones in combination with acute pain, when the clinician presses the gallbladder with the US probe (the sonographic Murphy's sign), has a 92.2 % positive predictive value for AC. In our preliminary experience, bedside US-performed by echoscopy (ES) and/or point-of-care US (POCUS) demonstrated good reliability in detecting signs of AC, and was always integrated with physical examination and performed by a skilled operator.

  14. Biopolymer system for permeability modification in porous media

    SciTech Connect

    Stepp, A.K.; Bryant, R.S.; Llave, F.M.

    1995-12-31

    New technologies are needed to reduce the current high rate of well abandonment. Improved sweep efficiency, reservoir conformance, and permeability modification can have a significant impact on oil recovery processes. Microorganisms can be used to selectively plug high-permeability zones to improve sweep efficiency and impart conformance control. Studies of a promising microbial system for polymer production were conducted to evaluate reservoir conditions in which this system would be effective. Factors which can affect microbial growth and polymer production include salinity, pH, temperature, divalent ions, presence of residual oil, and rock matrix. Flask tests and coreflooding experiments were conducted to optimize and evaluate the effectiveness of this system. Nuclear magnetic resonance imaging (NMRI) was used to visualize microbial polymer production in porous media. Changes in fluid distribution within the pore system of the core were detected.

  15. Structural determinants of glomerular permeability.

    PubMed

    Deen, W M; Lazzara, M J; Myers, B D

    2001-10-01

    Recent progress in relating the functional properties of the glomerular capillary wall to its unique structure is reviewed. The fenestrated endothelium, glomerular basement membrane (GBM), and epithelial filtration slits form a series arrangement in which the flow diverges as it enters the GBM from the fenestrae and converges again at the filtration slits. A hydrodynamic model that combines morphometric findings with water flow data in isolated GBM has predicted overall hydraulic permeabilities that are consistent with measurements in vivo. The resistance of the GBM to water flow, which accounts for roughly half that of the capillary wall, is strongly dependent on the extent to which the GBM surfaces are blocked by cells. The spatial frequency of filtration slits is predicted to be a very important determinant of the overall hydraulic permeability, in keeping with observations in several glomerular diseases in humans. Whereas the hydraulic resistances of the cell layers and GBM are additive, the overall sieving coefficient for a macromolecule (its concentration in Bowman's space divided by that in plasma) is the product of the sieving coefficients for the individual layers. Models for macromolecule filtration reveal that the individual sieving coefficients are influenced by one another and by the filtrate velocity, requiring great care in extrapolating in vitro observations to the living animal. The size selectivity of the glomerular capillary has been shown to be determined largely by the cellular layers, rather than the GBM. Controversial findings concerning glomerular charge selectivity are reviewed, and it is concluded that there is good evidence for a role of charge in restricting the transmural movement of albumin. Also discussed is an effect of albumin that has received little attention, namely, its tendency to increase the sieving coefficients of test macromolecules via steric interactions. Among the unresolved issues are the specific contributions of the

  16. The Membrane Permeability Outcome study.

    PubMed

    Locatelli, Francesco; Cavalli, Andrea; Manzoni, Celestina; Pontoriero, Giuseppe

    2011-01-01

    Many observational studies have consistently shown that high-flux hemodialysis has positive effects on the survival and morbidity of uremic patients when compared with low-flux hemodialysis. However, the HEMO study, a randomized trial designed to evaluate the effect of membrane permeability on patient survival, showed only an 8% non-statistically significant reduction of mortality, albeit a secondary analysis suggested an advantage for high-flux membranes in certain patient subgroups. The prospective, randomized Membrane Permeability Outcome (MPO) study investigated the impact of membrane permeability on survival in incident hemodialysis patients who had low albumin (≤4 g/dl) and normal albumin ( >4 g/dl) as separate randomization groups. Patients with serum albumin ≤4 g/dl had significantly better survival rates in the high-flux group compared with the low-flux group (p = 0.032). Moreover, a post-hoc secondary analysis showed that high-flux membranes may significantly improve survival in diabetic patients. No difference was found in patients with normal albumin levels. Considering the increasing number of dialysis patients with low serum albumin levels and with diabetes, the relevance of the MPO study led to the publication of a position statement by the European Renal Best Practice Advisory Board. This board strongly recommended that high-flux hemodialysis should be used for high-risk patients and, with a lower degree of evidence, even also for low-risk subjects due to the substantial reduction in β(2)-microglobulin levels observed in the high-flux group.

  17. An Approach to Measurment of Permeability/Permittivity Tensor of Ferrofluids

    NASA Astrophysics Data System (ADS)

    Mayer, Daniel

    2015-09-01

    The magnetic field acting on the ferrofluids causes microstructural conversions that result in a change of their permeability. For this physical phenomenon is referred to as field induced magnetism (FIMA). An experimental method is described for ferrofluids in this state to examine their permeability tensor. Also an analogous phenomenon is described also when there is a change of the ferrofluids permittivity. We call it field induced dielectric anisotropy (FIDA). The contribution describes the method of measuring of the permittivity tensor. It can be expected that the FIMA and FIDA of ferrofluids will find interesting applications in designing of various sensors, in measurement technology, in mechatronic and in other areas of practice.

  18. Study of AC/RF properties of SRF ingot niobium

    SciTech Connect

    Dhakal, Pashupati; Tsindlekht, Menachem I; Genkin, Valery M; Ciovati, Gianluigi; Myneni, Ganapati Rao

    2013-09-01

    In an attempt to correlate the performance of superconducting radiofrequency cavities made of niobium with the superconducting properties, we present the results of the magnetization and ac susceptibility of the niobium used in the superconducting radiofrequency cavity fabrication. The samples were subjected to buffer chemical polishing (BCP) surface and high temperature heat treatments, typically applied to the cavities fabrications. The analysis of the results show the different surface and bulk ac conductivity for the samples subjected to BCP and heat treatment. Furthermore, the RF surface impedance is measured on the sample using a TE011 microwave cavity for a comparison to the low frequency measurements.

  19. Introducing AC inductive reactance with a power tool

    NASA Astrophysics Data System (ADS)

    Bryant, Wesley; Baker, Blane

    2016-09-01

    The concept of reactance in AC electrical circuits is often non-intuitive and difficult for students to grasp. In order to address this lack of conceptual understanding, classroom exercises compare the predicted resistance of a power tool, based on electrical specifications, to measured resistance. Once students discover that measured resistance is smaller than expected, they are asked to explain these observations using previously studied principles of magnetic induction. Exercises also introduce the notion of inductive reactance and impedance in AC circuits and, ultimately, determine self-inductance of the motor windings within the power tool.

  20. Permeability of normal versus carious dentin.

    PubMed

    Pashley, E L; Talman, R; Horner, J A; Pashley, D H

    1991-10-01

    Although a number of reports have been published demonstrating that carious dentin is less permeable than normal dentin, these reports have been qualitative rather than quantitative. The purpose of this in vitro study was to apply a quantitative technique to the study of the permeability of carious human teeth before and after excavation, before and after removal of the smear layer and before and after preparation of a control cavity of similar size and depth in normal dentin subjected to the same measurements, for comparative purposes. Dentin permeability was measured as a hydraulic conductance. The permeability values measured at each step in the protocol were expressed as a percent of the maximum permeability of both cavities, permitting each tooth the serve as its own control. Carious lesions exhibited a slight degree of permeability (2.3 +/- 0.6% of controls) which remained unchanged after excavation of the lesions. Removal of the smear layer in the excavated carious lesions increased the permeability significantly to 6.9 +/- 3.2%. Preparation of a control cavity of the same area and depth increased the permeability slightly. Removal of its smear layer increased the permeability of the dentin 91%. These results confirm previous qualitative studies that carious dentin, even after excavation and removal of the smear layer has a very low permeability.

  1. Anisotropic hydraulic permeability in compressed articular cartilage.

    PubMed

    Reynaud, Boris; Quinn, Thomas M

    2006-01-01

    The extent to which articular cartilage hydraulic permeability is anisotropic is largely unknown, despite its importance for understanding mechanisms of joint lubrication, load bearing, transport phenomena, and mechanotransduction. We developed and applied new techniques for the direct measurement of hydraulic permeability within statically compressed adult bovine cartilage explant disks, dissected such that disk axes were perpendicular to the articular surface. Applied pressure gradients were kept small to minimize flow-induced matrix compaction, and fluid outflows were measured by observation of a meniscus in a glass capillary under a microscope. Explant disk geometry under radially unconfined axial compression was measured by direct microscopic observation. Pressure, flow, and geometry data were input to a finite element model where hydraulic permeabilities in the disk axial and radial directions were determined. At less than 10% static compression, near free-swelling conditions, hydraulic permeability was nearly isotropic, with values corresponding to those of previous studies. With increasing static compression, hydraulic permeability decreased, but the radially directed permeability decreased more dramatically than the axially directed permeability such that strong anisotropy (a 10-fold difference between axial and radial directions) in the hydraulic permeability tensor was evident for static compression of 20-40%. Results correspond well with predictions of a previous microstructurally-based model for effects of tissue mechanical deformations on glycosaminoglycan architecture and cartilage hydraulic permeability. Findings inform understanding of structure-function relationships in cartilage matrix, and suggest several biomechanical roles for compression-induced anisotropic hydraulic permeability in articular cartilage.

  2. Determination of permeability index using Stoneley slowness analysis, NMR models, and formation evaluations: a case study from a gas reservoir, south of Iran

    NASA Astrophysics Data System (ADS)

    Hosseini, Mirhasan; Javaherian, Abdolrahim; Movahed, Bahram

    2014-10-01

    In hydrocarbon reservoirs, permeability is one of the most critical parameters with a significant role in the production of hydrocarbon resources. Direct determination of permeability using Stoneley waves has always had some difficulties. In addition, some un-calibrated empirical models such as Nuclear Magnetic Resonance (NMR) models and petrophysical evaluation model (intrinsic permeability) do not provide reliable estimates of permeability in carbonate formations. Therefore, utilizing an appropriate numerical method for direct determination of permeability using Stoneley waves as well as an appropriate calibration method for the empirical models is necessary to have reliable results. This paper shows the application of a numerical method, called bisection method, in the direct determination of permeability from Stoneley wave slowness. In addition, a linear regression (least squares) method was used to calibrate the NMR models including Schlumberger Doll Research (SDR) and Timur-Coates models as well as the intrinsic permeability equation (permeability from petrophysical evaluations). The Express Pressure Tester (XPT) permeability was considered as an option for the reference permeability. Therefore, all permeability models were validated for the Stoneley permeability and calibrated for the empirical models with the XPT permeability. In order to have a quantitative assessment on the results and compare the results before and after the calibration, the Root Mean Squares Error (RMSE) was calculated for each of the used models. The results for the Stoneley permeability showed that, in many points there was not much difference between the Stoneley permeability calculated by the bisection method and the XPT permeability. Comparing the results showed that the calibration of the empirical models reduced their RMSE values. As a result of the calibration, the RMSE was decreased by about 39% for the SDR model, 18% for the Timur-Coates model, and 91% for the petrophysical

  3. Steam-water relative permeability

    SciTech Connect

    Ambusso, W.; Satik, C.; Home, R.N.

    1997-12-31

    A set of relative permeability relations for simultaneous flow of steam and water in porous media have been measured in steady state experiments conducted under the conditions that eliminate most errors associated with saturation and pressure measurements. These relations show that the relative permeabilities for steam-water flow in porous media vary approximately linearly with saturation. This departure from the nitrogen/water behavior indicates that there are fundamental differences between steam/water and nitrogen/water flows. The saturations in these experiments were measured by using a high resolution X-ray computer tomography (CT) scanner. In addition the pressure gradients were obtained from the measurements of liquid phase pressure over the portions with flat saturation profiles. These two aspects constitute a major improvement in the experimental method compared to those used in the past. Comparison of the saturation profiles measured by the X-ray CT scanner during the experiments shows a good agreement with those predicted by numerical simulations. To obtain results that are applicable to general flow of steam and water in porous media similar experiments will be conducted at higher temperature and with porous rocks of different wetting characteristics and porosity distribution.

  4. Brain permeability of inhaled corticosteroids.

    PubMed

    Arya, Vikram; Issar, Manish; Wang, Yaning; Talton, James D; Hochhaus, Guenther

    2005-09-01

    The aim of this study was to evaluate if the permeability of inhaled corticosteroids entering the brain is reduced and if P-glycoprotein (P-gp) transporters are involved. Currently employed inhaled corticosteroids were given intravenously and intratracheally to rats at a dose of 100 microg kg-1. An ex-vivo receptor binding assay was used to monitor over 12 h the glucocorticoid receptor occupancy in the brain and a systemic reference organ (kidney). The involvement of P-gp in the brain permeability of triamcinolone acetonide was assessed in wild-type mice and mdr1a(-/-) knockout mice (mice lacking the gene for expressing P-gp). After both forms of administration, the average brain receptor occupancies were 20-56% of those of the reference organ, with the more lipophilic drugs showing a more pronounced receptor occupation. While the receptor occupancies in the liver of wild-type and mdr1a(-/-) mice were similar after administration of triamcinolone acetonide, brain receptor occupancies in mdr1a(-/-) mice were significantly greater (mdr1a(-/-): 47.6%, 40.2-55.0%, n=14; 2; wild-type: 11.5+/-33.0%, n=14; 3). Penetration into the brain for inhaled corticosteroids (especially those of lower lipophilicity) is reduced. Experiments in mdr1a(-/-) mice confirmed the involvement of P-gp transporters. Further studies are needed to assess whether potential drug interactions at the transporter level are of pharmacological significance.

  5. Whole tissue AC susceptibility after superparamagnetic iron oxide contrast agent administration in a rat model

    NASA Astrophysics Data System (ADS)

    Lázaro, Francisco José; Gutiérrez, Lucía; Rosa Abadía, Ana; Soledad Romero, María; López, Antonio; Jesús Muñoz, María

    2007-04-01

    A magnetic AC susceptibility characterisation of rat tissues after intravenous administration of superparamagnetic iron oxide (Endorem ®), at the same dose as established for Magnetic Resonance Imaging (MRI) contrast enhancement in humans, has been carried out. The measurements reveal the presence of the contrast agent as well as that of physiological ferritin in liver and spleen while no traces have been magnetically detected in heart and kidney. This preliminary work opens suggestive possibilities for future biodistribution studies of any type of magnetic carriers.

  6. Layoff Handling Still Lags ACS Standards.

    ERIC Educational Resources Information Center

    Chemical and Engineering News, 1981

    1981-01-01

    Reviews termination procedures of professional chemists and the compliance of these terminations to the American Chemical Society's (ACS's) Professional Employment Guidelines. Provides the ACS guidelines. (DS)

  7. Vortex rings impinging on permeable boundaries

    NASA Astrophysics Data System (ADS)

    Mujal-Colilles, Anna; Dalziel, Stuart B.; Bateman, Allen

    2015-01-01

    Experiments with vortex rings impinging permeable and solid boundaries are presented in order to investigate the influence of permeability. Utilizing Particle Image Velocimetry, we compared the behaviour of a vortex ring impinging four different reticulated foams (with permeability k ˜ 26 - 85 × 10-8 m2) and a solid boundary. Results show how permeability affects the stretching phenomena of the vortex ring and the formation and evolution of the secondary vortex ring with opposite sign. Moreover, permeability also affects the macroscopic no-slip boundary condition found on the solid boundary, turning it into an apparent slip boundary condition for the most permeable boundary. The apparent slip-boundary condition and the flux exchange between the ambient fluid and the foam are jointly responsible for both the modified formation of the secondary vortex and changes on the vortex ring diameter increase.

  8. Clogging in permeable concrete: A review.

    PubMed

    Kia, Alalea; Wong, Hong S; Cheeseman, Christopher R

    2017-05-15

    Permeable concrete (or "pervious concrete" in North America) is used to reduce local flooding in urban areas and is an important sustainable urban drainage system. However, permeable concrete exhibits reduction in permeability due to clogging by particulates, which severely limits service life. This paper reviews the clogging mechanism and current mitigating strategies in order to inform future research needs. The pore structure of permeable concrete and characteristics of flowing particulates influence clogging, which occurs when particles build-up and block connected porosity. Permeable concrete requires regular maintenance by vacuum sweeping and pressure washing, but the effectiveness and viability of these methods is questionable. The potential for clogging is related to the tortuosity of the connected porosity, with greater tortuosity resulting in increased potential for clogging. Research is required to develop permeable concrete that can be poured on-site, which produces a pore structure with significantly reduced tortuosity.

  9. Shape effect on the negative equivalent permeabilities of chevronic thin films of silver

    NASA Astrophysics Data System (ADS)

    Jen, Yi-Jun; Yu, Ching-Wei; Wang, Yu-Hsiung

    2010-08-01

    In this work, the chevronic films composed of silver nanorods are fabricated using glancing angle deposition (GLAD). The chevronic structure is grown by bidepositing opposite nanorods sequentially: the substrate is oriented at the polar angle Φ=0 deg (about the substrate's normal) for the bottom rods and Φ180 deg for the top rods. When the applied electric field is parallel to the plane Φ= deg, the induced magnetic dipole moment between nanorods leads to a negative real part of the equivalent permeability. The equivalent refractive indices, the equivalent permittivities and the equivalent permeabilities of chevronic films with thickness 230 +/- 5 nm for p-polarized light are measured by walk-off interferometer. The equivalent permeabilities of chevronic films with lengths of top rods 291 nm, 409 and 509 nm and bottom rods 512 nm, 378 nm and 301 nm are measured to be -2.406+0.443 i, -3.870+2.109 i and -2.126+0.904 i at the wavelength of 639 nm, respectively. The shape affects the real part of the equivalent permeability significantly. When the length of the top rods is longer than that of the bottom rods, the magnetic dipole moment between nanorods is suppressed and the quantity of the equivalent permeability becomes small. The real part of equivalent permeability of the chevronic film is related to the lengths of top and bottom nanorods.

  10. Structure and magnetic properties of amorphous Fe-(Zr,Nb)-B melt spun alloys

    NASA Astrophysics Data System (ADS)

    Zamora, J.; Betancourt, I.

    2017-04-01

    In this work, we report the structure and magnetic behavior of an amorphous Fe81Zr5Nb4B10 melt-spun alloy. The radial distribution function (RDF) afforded the resolution of the nearest-neighbor configuration on the basis of the atom-pair distance information, for which the positions of each peak indicated the atom-to-atom separation involved for short-range ordering. The first peaks of RDF were attributed to the distances of B-B, Fe-Fe and Zr-Nb atomic pairs, indicating a glassy structure equivalent to a distorted bcc-Fe cluster. From magnetic measurements, a magnetic moment of 0.65 Bohr magneton per Fe atom was established, together with a Curie temperature of 334 K and an initial ac permeability of 550 for frequencies as high as 250 kHz. In addition, the magnetocaloric effect, quantified from isothermal magnetization measurements through the magnetic entropy variation, reached a maximum of 2.0 J/kg K for a magnetic field change of 2.0 T.

  11. Permeability of the blood-brain barrier predicts conversion from optic neuritis to multiple sclerosis.

    PubMed

    Cramer, Stig P; Modvig, Signe; Simonsen, Helle J; Frederiksen, Jette L; Larsson, Henrik B W

    2015-09-01

    Optic neuritis is an acute inflammatory condition that is highly associated with multiple sclerosis. Currently, the best predictor of future development of multiple sclerosis is the number of T2 lesions visualized by magnetic resonance imaging. Previous research has found abnormalities in the permeability of the blood-brain barrier in normal-appearing white matter of patients with multiple sclerosis and here, for the first time, we present a study on the capability of blood-brain barrier permeability in predicting conversion from optic neuritis to multiple sclerosis and a direct comparison with cerebrospinal fluid markers of inflammation, cellular trafficking and blood-brain barrier breakdown. To this end, we applied dynamic contrast-enhanced magnetic resonance imaging at 3 T to measure blood-brain barrier permeability in 39 patients with monosymptomatic optic neuritis, all referred for imaging as part of the diagnostic work-up at time of diagnosis. Eighteen healthy controls were included for comparison. Patients had magnetic resonance imaging and lumbar puncture performed within 4 weeks of onset of optic neuritis. Information on multiple sclerosis conversion was acquired from hospital records 2 years after optic neuritis onset. Logistic regression analysis showed that baseline permeability in normal-appearing white matter significantly improved prediction of multiple sclerosis conversion (according to the 2010 revised McDonald diagnostic criteria) within 2 years compared to T2 lesion count alone. There was no correlation between permeability and T2 lesion count. An increase in permeability in normal-appearing white matter of 0.1 ml/100 g/min increased the risk of multiple sclerosis 8.5 times whereas having more than nine T2 lesions increased the risk 52.6 times. Receiver operating characteristic curve analysis of permeability in normal-appearing white matter gave a cut-off of 0.13 ml/100 g/min, which predicted conversion to multiple sclerosis with a sensitivity of

  12. Permeability of the blood–brain barrier predicts conversion from optic neuritis to multiple sclerosis

    PubMed Central

    Modvig, Signe; Simonsen, Helle J.; Frederiksen, Jette L.; Larsson, Henrik B. W.

    2015-01-01

    Optic neuritis is an acute inflammatory condition that is highly associated with multiple sclerosis. Currently, the best predictor of future development of multiple sclerosis is the number of T2 lesions visualized by magnetic resonance imaging. Previous research has found abnormalities in the permeability of the blood–brain barrier in normal-appearing white matter of patients with multiple sclerosis and here, for the first time, we present a study on the capability of blood–brain barrier permeability in predicting conversion from optic neuritis to multiple sclerosis and a direct comparison with cerebrospinal fluid markers of inflammation, cellular trafficking and blood–brain barrier breakdown. To this end, we applied dynamic contrast-enhanced magnetic resonance imaging at 3 T to measure blood–brain barrier permeability in 39 patients with monosymptomatic optic neuritis, all referred for imaging as part of the diagnostic work-up at time of diagnosis. Eighteen healthy controls were included for comparison. Patients had magnetic resonance imaging and lumbar puncture performed within 4 weeks of onset of optic neuritis. Information on multiple sclerosis conversion was acquired from hospital records 2 years after optic neuritis onset. Logistic regression analysis showed that baseline permeability in normal-appearing white matter significantly improved prediction of multiple sclerosis conversion (according to the 2010 revised McDonald diagnostic criteria) within 2 years compared to T2 lesion count alone. There was no correlation between permeability and T2 lesion count. An increase in permeability in normal-appearing white matter of 0.1 ml/100 g/min increased the risk of multiple sclerosis 8.5 times whereas having more than nine T2 lesions increased the risk 52.6 times. Receiver operating characteristic curve analysis of permeability in normal-appearing white matter gave a cut-off of 0.13 ml/100 g/min, which predicted conversion to multiple sclerosis with a

  13. Factors affecting initial permeability of Co-substituted Ni-Zn-Cu ferrites

    SciTech Connect

    Byun, T.Y.; Byeon, S.C.; Hong, K.S.; Kim, C.K.

    1999-09-01

    Iron deficient compositions of (Ni{sub 0.2}Cu{sub 0.2}Zn{sub 0.6}){sub 1.02{minus}x}Co{sub x}Fe{sub 1.98}O{sub 4} (0 {le} x {le} 0.05) were prepared to investigate their initial permeability dependence on cobalt contents. Extrinsic factors such as grain size and sintered density change little in samples sintered at 900 C, so their effects on permeability can be neglected. Intrinsic factors such as saturation magnetization, magnetocrystalline anisotropy (K{sub 1}) and magnetoelastic anisotropy (K{sub {sigma}}) can not account for the variation of initial permeability with Co content. Measurement of thermoelectric power shows that the concentration of cation vacancies increases with Co content. Therefore, the local induced anisotropy increases by the ordering of Co ions cia increased cation vacancy concentration. This increase in induced anisotropy results in the decrease of initial permeability.

  14. Superconducting shielded core reactor with reduced AC losses

    DOEpatents

    Cha, Yung S.; Hull, John R.

    2006-04-04

    A superconducting shielded core reactor (SSCR) operates as a passive device for limiting excessive AC current in a circuit operating at a high power level under a fault condition such as shorting. The SSCR includes a ferromagnetic core which may be either closed or open (with an air gap) and extends into and through a superconducting tube or superconducting rings arranged in a stacked array. First and second series connected copper coils each disposed about a portion of the iron core are connected to the circuit to be protected and are respectively wound inside and outside of the superconducting tube or rings. A large impedance is inserted into the circuit by the core when the shielding capability of the superconducting arrangement is exceeded by the applied magnetic field generated by the two coils under a fault condition to limit the AC current in the circuit. The proposed SSCR also affords reduced AC loss compared to conventional SSCRs under continuous normal operation.

  15. Microwave permeability of stripe patterned FeCoN thin film

    NASA Astrophysics Data System (ADS)

    Wu, Yuping; Yang, Yong; Ma, Fusheng; Zong, Baoyu; Yang, Zhihong; Ding, Jun

    2017-03-01

    Magnetic stripe patterns are of great importance for microwave applications owing to their highly tunable microwave permeability by adjusting the geometrical dimensions. In this work, stripe patterned FeCoN films with 160 nm thickness are fabricated by using standard UV photolithography. Their microwave permeability are investigated systematically via both experiment and micromagnetic simulation. The good agreement between experimental and simulation results suggests that stripe width is crucial for the microwave magnetic properties of the stripe pattern. It is demonstrated by simulation that with increasing stripe width from 1 to 80 μm the initial permeability shows a continuous growth from about 8-322, whiles the resonance frequency drops dramatically from 18.7 to 3.1 GHz at 4 μm gap size. Smaller gap size would result in slightly increased initial permeability due to larger magnetic volume ratio, accompanied by decreased resonance frequency because of stronger magnetostatic interaction. Moreover, the experimental investigation on stripe length effect indicates that the stripe length should be kept as long as possible to achieve uniform bulk resonance mode and high permeability value. Insufficient stripe length would result in low frequency edge mode and decayed bulk mode. This study could provide valuable guidelines on the selection of proper geometry dimensions of FeCoN stripe patterns for high frequency applications.

  16. Frequency-Dependence of Relative Permeability in Steel

    SciTech Connect

    Bowler, N.

    2006-03-06

    A study to characterize metal plates by means of a model-based, broadband, four-point potential drop measurement technique has shown that the relative permeability of alloy 1018 low-carbon steel is complex and a function of frequency. A magnetic relaxation is observed at approximately 5 kHz. The relaxation can be described in terms of a parametric (Cole-Cole) model. Factors which influence the frequency, amplitude and breadth of the relaxation, such as applied current amplitude, sample geometry and disorder (e.g. percent carbon content and surface condition), are considered.

  17. Quantitative Perfusion and Permeability Biomarkers in Brain Cancer from Tomographic CT and MR Images

    PubMed Central

    Eilaghi, Armin; Yeung, Timothy; d’Esterre, Christopher; Bauman, Glenn; Yartsev, Slav; Easaw, Jay; Fainardi, Enrico; Lee, Ting-Yim; Frayne, Richard

    2016-01-01

    Dynamic contrast-enhanced perfusion and permeability imaging, using computed tomography and magnetic resonance systems, are important techniques for assessing the vascular supply and hemodynamics of healthy brain parenchyma and tumors. These techniques can measure blood flow, blood volume, and blood–brain barrier permeability surface area product and, thus, may provide information complementary to clinical and pathological assessments. These have been used as biomarkers to enhance the treatment planning process, to optimize treatment decision-making, and to enable monitoring of the treatment noninvasively. In this review, the principles of magnetic resonance and computed tomography dynamic contrast-enhanced perfusion and permeability imaging are described (with an emphasis on their commonalities), and the potential values of these techniques for differentiating high-grade gliomas from other brain lesions, distinguishing true progression from posttreatment effects, and predicting survival after radiotherapy, chemotherapy, and antiangiogenic treatments are presented. PMID:27398030

  18. Apparatus and method for handling magnetic particles in a fluid

    DOEpatents

    Holman, David A.; Grate, Jay W.; Bruckner-Lea, Cynthia J.

    2000-01-01

    The present invention is an apparatus and method for handling magnetic particles suspended in a fluid, relying upon the known features of a magnetic flux conductor that is permeable thereby permitting the magnetic particles and fluid to flow therethrough; and a controllable magnetic field for the handling. The present invention is an improvement wherein the magnetic flux conductor is a monolithic porous foam.

  19. Effect of Dead Algae on Soil Permeability

    SciTech Connect

    Harvey, R.S.

    2003-02-21

    Since existing basins support heavy growths of unicellular green algae which may be killed by temperature variation or by inadvertent pH changes in waste and then deposited on the basin floor, information on the effects of dead algae on soil permeability was needed. This study was designed to show the effects of successive algal kills on the permeability of laboratory soil columns.

  20. Influence of fiber packing structure on permeability

    NASA Technical Reports Server (NTRS)

    Cai, Zhong; Berdichevsky, Alexander L.

    1993-01-01

    The study on the permeability of an aligned fiber bundle is the key building block in modeling the permeability of advanced woven and braided preforms. Available results on the permeability of fiber bundles in the literature show that a substantial difference exists between numerical and analytical calculations on idealized fiber packing structures, such as square and hexagonal packing, and experimental measurements on practical fiber bundles. The present study focuses on the variation of the permeability of a fiber bundle under practical process conditions. Fiber bundles are considered as containing openings and fiber clusters within the bundle. Numerical simulations on the influence of various openings on the permeability were conducted. Idealized packing structures are used, but with introduced openings distributed in different patterns. Both longitudinal and transverse flow are considered. The results show that openings within the fiber bundle have substantial effect on the permeability. In the longitudinal flow case, the openings become the dominant flow path. In the transverse flow case, the fiber clusters reduce the gap sizes among fibers. Therefore the permeability is greatly influenced by these openings and clusters, respectively. In addition to the porosity or fiber volume fraction, which is commonly used in the permeability expression, another fiber bundle status parameter, the ultimate fiber volume fraction, is introduced to capture the disturbance within a fiber bundle.

  1. A method of determination of permeability

    SciTech Connect

    Kuznetsov, S.V.; Trofimov, V.A.

    2007-11-15

    A method is proposed for determining permeability of coals under conditions of steady-state deformation and stationary filtration mode by employing a reference core made of gas-non-sorbing material with a known permeability. The approach has been developed to assess the time of transition to the stable filtration.

  2. Electric field and losses at AC self field mode in MF composites

    SciTech Connect

    Fukui, S.; Hlasnik, I.; Tsukamoto, O.; Amemiya, N. ); Polak, M.; Kottman, P. . Inst. of Electrical Engineering)

    1994-07-01

    Studies of the current-voltage characteristics of typical superconducting wires under static and dynamic conditions up to 50 Hz frequency have revealed much higher instantaneous local loss power densities in an external DC magnetic field than those which occur by magnetization in a transverse AC magnetic field. In this paper, the measured loss characteristics are compared with theoretical ones derived from the critical state model, and the self field AC loss are also estimated. Possible errors that can result by applying the critical state model are discussed.

  3. Location Dependence of a MEMS Electromagnetic Transducer with respect to an AC Power Source

    NASA Astrophysics Data System (ADS)

    Houlihan, Ruth; Olszewski, Oskar; Waldron, Finbarr; O'Neill, Mike; Mathewson, Alan; Jackson, Nathan

    2016-10-01

    A MEMS, silicon based device with a piezoelectric layer and an integrated magnet is presented for magnetic to electrical transduction. The cantilever structure can be configured either as an energy harvester to harvest power from an AC power line or as an AC current sensor. The positioning of the transducer with respect to the AC conductor is critical in both scenarios. For the energy scavenger, correct positioning is required to optimize the harvested power. For the current sensor, it is necessary to optimise the sensitivity of the sensor. This paper considers the effect of the relative position of the transducer with respect to the wire on the resulting electromagnetic forces and torques driving the device. It is shown here that the magnetic torque acting on a cantilever beam with an integrated magnet and in the vicinity of an alternating electromagnetic field is a very significant driver of the cantilever oscillations.

  4. Magnetically enhanced high-specificity virus detection using bio-activated magnetic nanoparticles with antibodies as labeling markers.

    PubMed

    Yang, S Y; Wang, W C; Lan, C B; Chen, C H; Chieh, J J; Horng, H E; Hong, Chin-Yih; Yang, H C; Tsai, C P; Yang, C Y; Cheng, I C; Chung, W C

    2010-03-01

    This study describes magnetically driven suppression of cross-reactions among molecules. First, the magnetic nanoparticles are coated with bio-probes and dispersed in liquid. The bio-probes can then bind with homologous or heterologous bio-targets. When alternating-current (ac) magnetic fields are applied, magnetic nanoparticles rotate driven by ac magnetic fields. Thus, the bio-targets bound on the surface of magnetic nanoparticles experience a centrifugal force. The centrifugal force can be manipulated by adjusting the angular frequency of the rotating magnetic nanoparticles. The angular frequency is determined by the applied ac magnetic field frequency. Since the binding force for good binding is much higher than that of poor binding, frequency manipulation is needed for the centrifugal force to be higher than the poor-binding force but lower than the good-binding force. Therefore, poor binding which contributes to cross reactions between molecules can be suppressed efficiently by control of the ac magnetic field frequency.

  5. Research on red cell membrane permeability in arterial hypertension.

    PubMed

    Gatina, R; Balta, N; Moisin, C; Burtea, C; Botea, S; Ioan, M; Teleianu, C

    1998-01-01

    Arterial hypertension, including the elucidation of hypertension pathogenic mechanisms involving elements in the composition of the blood, continues to represent a topical research area. Recent work, such as nuclear magnetic resonance studies looking into red cell permeability, illustrates the presence of modifications of red cell permeability to water (RCPW) related to the stage of arterial hypertension. The identification of a significant increase of RCPW compared to that present in the population with normal arterial pressure values can be useful both in early diagnosis and in warning about a possible predisposition for this condition. At the same time, the dynamic investigation of protonic relaxation time of both intra- and extra-erythrocytic water, the assessment of proton exchange time across the red cell and the calculation of permeability to water enable one not only to diagnose arterial hypertension but also to ascertain the evolution of the disease, its complications and the effectiveness of anti-hypertensive medication. Our studies have also proven the existence of a correlation between the values of systolic arterial pressure and red cell permeability to water. The curve describing the interdependence of the two values has the shape of a bell, in the case of males. The peak of the curve is reached for a systolic pressure of 160 mmHg and gets below the values of the control group in the case of systolic pressures above 200 mmHg. The RCPW test can also be considered a valuable indicator in evaluating the risk of stroke in hypertensive patients. In the chronic therapy of arterial hypertension with various types of anti-hypertensive drugs, one can note differences in the RCPW values related to the effectiveness of the respective medication, to the clinical form and stage of the disease, the sex of the patient as well as to the existence of cerebro-vascular complications.

  6. Analysis of Instrumentation Selection and Placement to Monitor the Hydrologic Performance of Permeable Pavement Systems and Bioinfiltration Areas at the Edison Environmental Center in New Jersey

    EPA Science Inventory

    In 2009, the U.S. Environmental Protection Agency constructed a 0.4-ha (1-ac) parking lot surfaced with three different permeable pavement types (interlocking concrete pavers, porous concrete, and porous asphalt) and six bioinfiltration areas with three different drainage area to...

  7. NONLINEAR DIAGNOSTICS USING AC DIPOLES.

    SciTech Connect

    PEGGS,S.

    1999-03-29

    There are three goals in the accurate nonlinear diagnosis of a storage ring. First, the beam must be moved to amplitudes many times the natural beam size. Second, strong and long lasting signals must be generated. Third, the measurement technique should be non-destructive. Conventionally, a single turn kick moves the beam to large amplitudes, and turn-by-turn data are recorded from multiple beam position monitors (BPMs) [1-6]. Unfortunately, tune spread across the beam causes the center of charge beam signal to ''decohere'' on a time scale often less than 100 turns. Filamentation also permanently destroys the beam emittance (in a hadron ring). Thus, the ''strong single turn kick'' technique successfully achieves only one out of the three goals. AC dipole techniques can achieve all three. Adiabatically excited AC dipoles slowly move the beam out to large amplitudes. The coherent signals then recorded last arbitrarily long. The beam maintains its original emittance if the AC dipoles are also turned off adiabatically, ready for further use. The AGS already uses an RF dipole to accelerate polarized proton beams through depolarizing resonances with minimal polarization loss [7]. Similar AC dipoles will be installed in the horizontal and vertical planes of both rings in RHIC [8]. The RHIC AC dipoles will also be used as spin flippers, and to measure linear optical functions [9].

  8. Anisotropy of permeability in faulted porous sandstones

    NASA Astrophysics Data System (ADS)

    Farrell, N. J. C.; Healy, D.; Taylor, C. W.

    2014-06-01

    Studies of fault rock permeabilities advance the understanding of fluid migration patterns around faults and contribute to predictions of fault stability. In this study a new model is proposed combining brittle deformation structures formed during faulting, with fluid flow through pores. It assesses the impact of faulting on the permeability anisotropy of porous sandstone, hypothesising that the formation of fault related micro-scale deformation structures will alter the host rock porosity organisation and create new permeability pathways. Core plugs and thin sections were sampled around a normal fault and oriented with respect to the fault plane. Anisotropy of permeability was determined in three orientations to the fault plane at ambient and confining pressures. Results show that permeabilities measured parallel to fault dip were up to 10 times higher than along fault strike permeability. Analysis of corresponding thin sections shows elongate pores oriented at a low angle to the maximum principal palaeo-stress (σ1) and parallel to fault dip, indicating that permeability anisotropy is produced by grain scale deformation mechanisms associated with faulting. Using a soil mechanics 'void cell model' this study shows how elongate pores could be produced in faulted porous sandstone by compaction and reorganisation of grains through shearing and cataclasis.

  9. Fluid permeability of deformable fracture networks

    SciTech Connect

    Brown, S.R.; Bruhn, R.L.

    1997-04-01

    The authors consider the problem of defining the fracture permeability tensor for each grid lock in a rock mass from maps of natural fractures. For this purpose they implement a statistical model of cracked rock due to M. Oda [1985], where the permeability tensor is related to the crack geometry via a volume average of the contribution from each crack in the population. In this model tectonic stress is implicitly coupled to fluid flow through an assumed relationship between crack aperture and normal stress across the crack. The authors have included the following enhancements to the basic model: (1) a realistic model of crack closure under stress has been added along with the provision to apply tectonic stresses to the fracture system in any orientation, the application of stress results in fracture closure and consequently a reduction in permeability; (2) the fracture permeability can be superimposed onto an arbitrary anisotropic matrix permeability; (3) the fracture surfaces are allowed to slide under the application of shear stress, causing fractures to dilate and result in a permeability increase. Through an example, the authors demonstrate that significant changes in permeability magnitudes and orientations are possible when tectonic stress is applied to a fracture system.

  10. Intestinal permeability, leaky gut, and intestinal disorders.

    PubMed

    Hollander, D

    1999-10-01

    A major task of the intestine is to form a defensive barrier to prevent absorption of damaging substances from the external environment. This protective function of the intestinal mucosa is called permeability. Clinicians can use inert, nonmetabolized sugars such as mannitol, rhamnose, or lactulose to measure the permeability barrier or the degree of leakiness of the intestinal mucosa. Ample evidence indicates that permeability is increased in most patients with Crohn's disease and in 10% to 20% of their clinically healthy relatives. The abnormal leakiness of the mucosa in Crohn's patients and their relatives can be greatly amplified by aspirin preadministration. Permeability measurements in Crohn's patients reflect the activity, extent, and distribution of the disease and may allow us to predict the likelihood of recurrence after surgery or medically induced remission. Permeability is also increased in celiac disease and by trauma, burns, and nonsteroidal anti-inflammatory drugs. The major determinant of the rate of intestinal permeability is the opening or closure of the tight junctions between enterocytes in the paracellular space. As we broaden our understanding of the mechanisms and agents that control the degree of leakiness of the tight junctions, we will be increasingly able to use permeability measurements to study the etiology and pathogenesis of various disorders and to design or monitor therapies for their management.

  11. Permeable Gas Flow Influences Magma Fragmentation Speed.

    NASA Astrophysics Data System (ADS)

    Richard, D.; Scheu, B.; Spieler, O.; Dingwell, D.

    2008-12-01

    Highly viscous magmas undergo fragmentation in order to produce the pyroclastic deposits that we observe, but the mechanisms involved remain unclear. The overpressure required to initiate fragmentation depends on a number of physical parameters, such as the magma's vesicularity, permeability, tensile strength and textural properties. It is clear that these same parameters control also the speed at which a fragmentation front travels through magma when fragmentation occurs. Recent mathematical models of fragmentation processes consider most of these factors, but permeable gas flow has not yet been included in these models. However, it has been shown that permeable gas flow through a porous rock during a sudden decompression event increases the fragmentation threshold. Fragmentation experiments on natural samples from Bezymianny (Russia), Colima (Mexico), Krakatau (Indonesia) and Augustine (USA) volcanoes confirm these results and suggest in addition that high permeable flow rates may increase the speed of fragmentation. Permeability from the investigated samples ranges from as low as 5 x 10-14 to higher than 9 x 10- 12 m2 and open porosity ranges from 16 % to 48 %. Experiments were performed for each sample series at applied pressures up to 35 MPa. Our results indicate that the rate of increase of fragmentation speed is higher when the permeability is above 10-12 m2. We confirm that it is necessary to include the influence of permeable flow on fragmentation dynamics.

  12. Magnetic effects on thermocouples

    NASA Astrophysics Data System (ADS)

    Beguš, Samo; Bojkovski, Jovan; Drnovšek, Janko; Geršak, Gregor

    2014-03-01

    Thermometers in laboratory environment and industrial applications are often subject to extraneous, usually unwanted and uncontrolled magnetic fields. Magnetic field influence can be minimized, but cannot be fully cancelled out. Even more, in most cases, there is no awareness of the existence of magnetic fields, let alone their effect on measurement instrumentation. In the past, sensitivity to high dc magnetic fields has been investigated in cryogenics and at high temperatures. More recently, the magnetic effect on weak dc magnetic fields was presented. The goal of this paper was to analyse and empirically and experimentally prove the magnetic sensitivity of thermocouples exposed to low magnetic fields: both dc and ac. Precision and uniform alternating and direct magnetic flux densities were generated by means of permanent magnets and power amplifiers with air-cored coils. The magnetic effect on ferromagnetic and non-ferromagnetic thermocouples at liquid-nitrogen-boiling point (-196 °C), ice point (0 °C), in water (17 °C) and at melting point of gallium fixed point cell (29.7646 °C) was investigated. Magnetic-field-dependent temperature errors of up to 700 mK (at 5.3 mT: dc) and up to 1 °C (at 10 mT: ac 50 Hz magnetic fields) were detected. From the results, it can be concluded that, ideally for temperature measurements of the highest accuracy in the above-cryogenic temperature range, magnetic sensitivity should be estimated and taken into account either as the correction of an error and/or as an additional source of measurement uncertainty. Special consideration should be given to thermocouple orientation relative to the magnetic field direction, influence of metal enclosures and magnetization effects on ferromagnetic components of thermocouples.

  13. An improved technique for computing permeability from NMR measurements in mudstones

    NASA Astrophysics Data System (ADS)

    Daigle, Hugh; Dugan, Brandon

    2011-08-01

    We develop a technique for extending nuclear magnetic resonance (NMR) permeability estimation to clay-rich sediments. Our technique builds on the Schlumberger-Doll Research (SDR) equation by using porosity, grain size, specific surface, and magnetic susceptibility data to yield more accurate permeability estimation in mudstones with large pore surface areas and complex mineralogies. Based on measurements of natural sediments as well as resedimented laboratory mixtures of silica, bentonite, and kaolinite powders, we find that our method predicts permeability values that match measured values over four orders of magnitude and among lithologies that vary widely in grain size, mineralogy, and surface area. Our results show that the relationship between NMR data and permeability is a function of mineralogy and grain geometry, and that permeability predictions in clay-rich sediments can be improved with insights regarding the nature of the pore system made by the Kozeny theory. This technique extends the utility of NMR measurements beyond typical reservoir-quality rocks to a wide range of lithologies.

  14. Permeability Barrier Generation in the Martian Lithosphere

    NASA Astrophysics Data System (ADS)

    Schools, Joe; Montési, Laurent

    2015-11-01

    Permeability barriers develop when a magma produced in the interior of a planet rises into the cooler lithosphere and crystallizes more rapidly than the lithosphere can deform (Sparks and Parmentier, 1991). Crystallization products may then clog the porous network in which melt is propagating, reducing the permeability to almost zero, i.e., forming a permeability barrier. Subsequent melts cannot cross the barrier. Permeability barriers have been useful to explain variations in crustal thickness at mid-ocean ridges on Earth (Magde et al., 1997; Hebert and Montési, 2011; Montési et al., 2011). We explore here under what conditions permeability barriers may form on Mars.We use the MELTS thermodynamic calculator (Ghiorso and Sack, 1995; Ghiorso et al., 2002; Asimow et al., 2004) in conjunction with estimated Martian mantle compositions (Morgan and Anders, 1979; Wänke and Dreibus, 1994; Lodders and Fegley, 1997; Sanloup et al., 1999; Taylor 2013) to model the formation of permeability barriers in the lithosphere of Mars. In order to represent potential past and present conditions of Mars, we vary the lithospheric thickness, mantle potential temperature (heat flux), oxygen fugacity, and water content.Our results show that permeability layers can develop in the thermal boundary layer of the simulated Martian lithosphere if the mantle potential temperature is higher than ~1500°C. The various Martian mantle compositions yield barriers in the same locations, under matching variable conditions. There is no significant difference in barrier location over the range of accepted Martian oxygen fugacity values. Water content is the most significant influence on barrier development as it reduces the temperature of crystallization, allowing melt to rise further into the lithosphere. Our lower temperature and thicker lithosphere model runs, which are likely the most similar to modern Mars, show no permeability barrier generation. Losing the possibility of having a permeability

  15. Comparison study of ferrofluid and powder iron oxide nanoparticle permeability across the blood-brain barrier.

    PubMed

    Hoff, Dan; Sheikh, Lubna; Bhattacharya, Soumya; Nayar, Suprabha; Webster, Thomas J

    2013-01-01

    In the present study, the permeability of 11 different iron oxide nanoparticle (IONP) samples (eight fluids and three powders) was determined using an in vitro blood-brain barrier model. Importantly, the results showed that the ferrofluid formulations were statistically more permeable than the IONP powder formulations at the blood-brain barrier, suggesting a role for the presently studied in situ synthesized ferrofluid formulations using poly(vinyl) alcohol, bovine serum albumin, collagen, glutamic acid, graphene, and their combinations as materials which can cross the blood-brain barrier to deliver drugs or have other neurological therapeutic efficacy. Conversely, the results showed the least permeability across the blood-brain barrier for the IONP with collagen formulation, suggesting a role as a magnetic resonance imaging contrast agent but limiting IONP passage across the blood-brain barrier. Further analysis of the data yielded several trends of note, with little correlation between permeability and fluid zeta potential, but a larger correlation between permeability and fluid particle size (with the smaller particle sizes having larger permeability). Such results lay the foundation for simple modification of iron oxide nanoparticle formulations to either promote or inhibit passage across the blood-brain barrier, and deserve further investigation for a wide range of applications.

  16. ISTTOK upgrade towards AC and remote operation

    NASA Astrophysics Data System (ADS)

    Fernandes, H.; Silva, C.; Carvalho, B.; Sousa, J.; Valcárcel, D.; Neto, A.; Fortunato, J.; Carvalho, I.; Varandas, C. A. F.

    2006-12-01

    ISTTOK has performed one of the earliest experiments of AC tokamak operation showing that long discharges could be produced merely with inductive current drive. However, due to the design of the machine, the data acquisition system and the power supplies, a limit of 250 ms (six times the nominal forward shot duration) is currently imposed. In this paper the relevant constrains to attain current operation up to the limit of the stable toroidal magnetic field (3s) are discussed and the work being carried out to achieve this goal is presented. The conditions that shall be accomplished are: (i) removing the power deposited on the limiters; (ii) density control through gas puffing and monitoring the recycling from the walls; (iii) assessment of the free magnetic flux available on the iron core (Wmax=0.2 Vs); (iv) reformulation of the data acquisition system towards an event driven philosophy maintaining the actual distributed architecture but allowing a real-time control; (v) active control of the equilibrium magnetic fields implementing a digital plasma position estimator and actuator through new power supplies for the poloidal magnetic fields. As a new high level software was needed to implement all this features, the ISTTOK data acquisition system and control has been totally redesigned in JAVA/SQL database technology and time stamps events were adopted to catalogue the data. This software has been design keeping in mind the needs for remote participation and operation of the machine. Therefore, a cooperative environment has been implemented where several persons can be connected together to the platform, programming their own devices and exchanging knowledge or opinions through an embedded chat.

  17. Gas Permeable Chemochromic Compositions for Hydrogen Sensing

    NASA Technical Reports Server (NTRS)

    Bokerman, Gary (Inventor); Mohajeri, Nahid (Inventor); Muradov, Nazim (Inventor); Tabatabaie-Raissi, Ali (Inventor)

    2013-01-01

    A (H2) sensor composition includes a gas permeable matrix material intermixed and encapsulating at least one chemochromic pigment. The chemochromic pigment produces a detectable change in color of the overall sensor composition in the presence of H2 gas. The matrix material provides high H2 permeability, which permits fast permeation of H2 gas. In one embodiment, the chemochromic pigment comprises PdO/TiO2. The sensor can be embodied as a two layer structure with the gas permeable matrix material intermixed with the chemochromic pigment in one layer and a second layer which provides a support or overcoat layer.

  18. Annealing effects on magnetic properties of silicone-coated iron-based soft magnetic composites

    NASA Astrophysics Data System (ADS)

    Wu, Shen; Sun, Aizhi; Zhai, Fuqiang; Wang, Jin; Zhang, Qian; Xu, Wenhuan; Logan, Philip; Volinsky, Alex A.

    2012-03-01

    This paper focuses on novel iron-based soft magnetic composites synthesis utilizing high thermal stability silicone resin to coat iron powder. The effect of an annealing treatment on the magnetic properties of synthesized magnets was investigated. The coated silicone insulating layer was characterized by scanning electron microscopy and energy dispersive X-ray spectroscopy. Silicone uniformly coated the powder surface, resulting in a reduction of the imaginary part of the permeability, thereby increasing the electrical resistivity and the operating frequency of the synthesized magnets. The annealing treatment increased the initial permeability, the maximum permeability, and the magnetic induction, and decreased the coercivity. Annealing at 580 °C increased the maximum permeability by 72.5%. The result of annealing at 580 °C shows that the ferromagnetic resonance frequency increased from 2 kHz for conventional epoxy resin coated samples to 80 kHz for the silicone resin insulated composites.

  19. Magnetic Nernst effect

    NASA Astrophysics Data System (ADS)

    Brechet, Sylvain D.; Ansermet, Jean-Philippe

    2015-09-01

    The thermodynamics of irreversible processes in continuous media predicts the existence of a magnetic Nernst effect that results from a magnetic analog to the Seebeck effect in a ferromagnet and magnetophoresis occurring in a paramagnetic electrode in contact with the ferromagnet. Thus, a voltage that has DC and AC components is expected across a Pt electrode as a response to the inhomogeneous magnetic induction field generated by magnetostatic waves of an adjacent YIG slab subject to a temperature gradient. The voltage frequency and dependence on the orientation of the applied magnetic induction field are quite distinct from that of spin pumping.

  20. Magnetic bearing and motor

    NASA Technical Reports Server (NTRS)

    Studer, Philip A. (Inventor)

    1983-01-01

    A magnetic bearing assembly (10) has an intermediate rotatable section (33) having an outer cylindrical member (30) coaxially suspended by a torsion wire (72) around an axially polarized cylindrical magnet (32). Axial alignment between the pole faces (40-43) of the intermediate section (33) and end surfaces (50-53) of opposed end bells (20, 22) provides a path of least reluctance across intervening air gaps (60-63) for the magnetic flux emanating from magnet (32). Radial dislocation increases the reluctance and creates a radial restoring force. Substitution of radially polarized magnets 107 fixed to a magnetically permeable cylinder (32') and insertion of pairs of armature coil windings (109-112) between the cylinder pair (33') provides an integral magnetic bearing and torsion motor (100) able to provide arcuately limited rotational drive.

  1. Electrically Tunable Magnetism in Magnetic Topological Insulators

    NASA Astrophysics Data System (ADS)

    Zhang, Shou-Cheng; Wang, Jing; Lian, Biao

    2015-03-01

    The external controllability of the magnetic properties in topological insulators would be important both for fundamental and practical interests. Here we predict the electric-field control of ferromagnetism in a thin film of insulating magnetic topological insulators. The decrease of band inversion by the application of electric fields results in a reduction of magnetic susceptibility, and hence in the modication of magnetism. Remarkably, the electric field could even induce the magnetic quantum phase transition from ferromagnetism to paramagnetism. We further propose a topological transistor device in which the dissipationless charge transport of chiral edge states is controlled by an electric field. The simultaneous electrical control of magnetic order and chiral edge transport in such a device may lead to electronic and spintronic applications for topological insulators. This work is supported by the U.S. Department of Energy, Office of Basic Energy Sciences, Division of Materials Sciences and Engineering, under Contract No. DE-AC02-76SF00515.

  2. Slow magnetic relaxation in a cobalt magnetic chain.

    PubMed

    Yang, Chen-I; Chuang, Po-Hsiang; Lu, Kuang-Lieh

    2011-04-21

    A homospin ladder-like chain, [Co(Hdhq)(OAc)](n) (1; H(2)dhq = 2,3-dihydroxyquinoxaline), shows a single-chain-magnet-like (SCM-like) behavior with the characteristics of frequency dependence of the out-of-phase component in alternating current (ac) magnetic susceptibilities and hysteresis loops.

  3. Spectroscopy of magnetic excitations in magnetic superconductors using vortex motion.

    PubMed

    Bulaevskii, L N; Hruska, M; Maley, M P

    2005-11-11

    In magnetic superconductors a moving vortex lattice is accompanied by an ac magnetic field which leads to the generation of spin waves. At resonance conditions the dynamics of vortices in magnetic superconductors changes drastically, resulting in strong peaks in the dc I-V characteristics at voltages at which the washboard frequency of the vortex lattice matches the spin wave frequency omegaS(g), where g are the reciprocal vortex lattice vectors. We show that if the washboard frequency lies above the magnetic gap, measurement of the I-V characteristics provides a new method to obtain information on the spectrum of magnetic excitations in borocarbides and cuprate layered magnetic superconductors.

  4. NASA In-step: Permeable Membrane Experiment

    NASA Technical Reports Server (NTRS)

    1992-01-01

    Viewgraphs on the Permeable Membrane Experiment are presented. An experiment overview is given. The Membrane Phase Separation Experiment, Membrane Diffusion Interference Experiment, and Membrane Wetting Experiment are described. Finally, summary and conclusions are discussed.

  5. The Edison Environmental Center Permeable Pavement Site

    EPA Science Inventory

    This a presentation for a Community Outreach Event called "Chemistry Works and Celebration of International Year of Chemistry." It will review the permeable pavement research project at the Edison Environmental center.

  6. Permeability of rayon based polymer composites

    NASA Technical Reports Server (NTRS)

    Stokes, E. H.

    1992-01-01

    Several types of anomalous rayon based phenolic behavior have been observed in post-fired nozzles and exit cones. Many of these events have been shown to be related to the development of internal gas pressure within the material. The development of internal gas pressure is a function of the amount of gas produced within the material and the rate at which that gas is allowed to escape. The latter property of the material is referred to as the material's permeability. The permeability of two dimensional carbonized rayon based phenolic composites is a function of material direction, temperature, and stress/strain state. Recently significant differences in the permeability of these materials has been uncovered which may explain their inconsistent performance. This paper summarizes what is known about the permeability of these materials to date and gives possible implications of these finding to the performance of these materials in an ablative environment.

  7. Permeable Reactive Zones for Groundwater Remediation

    EPA Science Inventory

    The presentation will cover aspects of the application of permeable reactive zones to treat contaminated ground water. Specific field studies will be discussed covering both granular iron-based and organic carbon-based reactive barriers. Specific contaminants addressed include:...

  8. Permeability After Impact Testing of Composite Laminates

    NASA Technical Reports Server (NTRS)

    Nettles, A.T.; Munafo, Paul (Technical Monitor)

    2002-01-01

    Since composite laminates are beginning to be identified for use in reusable launch vehicle propulsion systems, an understanding of their permeance is needed. A foreign object impact event can cause a localized area of permeability (leakage) in a polymer matrix composite and it is the aim of this study to assess a method of quantifying permeability-after-impact results. A simple test apparatus is presented and variables that could affect the measured values of permeability-after-impact were assessed. Once it was determined that valid numbers were being measured, a fiber/resin system was impacted at various impact levels and the resulting permeability measured, first with a leak check solution (qualitative) then using the new apparatus (quantitative). The results showed that as the impact level increased, so did the measured leakage. As the pressure to the specimen was increased, the leak rate was seen to increase in a non-linear fashion for almost all of the specimens tested.

  9. Permeability After Impact Testing of Composite Laminates

    NASA Technical Reports Server (NTRS)

    Nettles, Alan T.

    2003-01-01

    Since composite laminates are beginning to be identified for use in reusable launch vehicle propulsion systems, an understanding of their permeance is needed. A foreign object impact event can cause a localized area of permeability (leakage) in a polymer matrix composite and it is the aim of this study to assess a method of quantifying permeability-after-impact results. A simple test apparatus is presented and variables that could affect the measured values of permeability-after-impact were assessed. Once it was determined that valid numbers were being measured, a fiber/resin system was impacted at various impact levels and the resulting permeability measured, first with a leak check solution (qualitative) then using the new apparatus (quantitative). The results showed that as the impact level increased, so did the measured leakage. As the pressure to the specimen was increased, the leak rate was seen to increase in a non-linear fashion for almost all of the specimens tested.

  10. Flexible Sandwich Diaphragms Are Less Permeable

    NASA Technical Reports Server (NTRS)

    Michalovic, John G.; Vassallo, Franklin A.

    1993-01-01

    Diaphragms for use in refrigerator compressors made as laminates of commercially available elastomers and metals. Diaphragms flexible, but less permeable by chlorofluorocarbon refrigerant fluids than diaphragms made of homogeneous mixtures of materials.

  11. PERMEABLE REACTIVE BARRIERS FOR GROUNDWATER REMEDIATION

    EPA Science Inventory

    Permeable reactive barriers (PRB's) are an emerging, alternative in-situ approach for remediating groundwater contamination that combine subsurface fluid flow management with a passive chemical treatment zone. Removal of contaminants from the groundwater plume is achieved by alt...

  12. PERMEABLE REACTIVE BARRIERS FOR GROUND WATER REMEDIATION

    EPA Science Inventory

    Permeable reactive barriers (PRB's) are an emerging, alternative in-situ approach for remediating groundwater contamination that combine subsurface fluid flow management with a passive chemical treatment zone. Removal of contaminants from the groundwater plume is achieved by alt...

  13. Permeability retrieval in InP-based waveguide optical device combined with metamaterial.

    PubMed

    Amemiya, Tomohiro; Myoga, Seiji; Shindo, Takahiko; Murai, Eijun; Nishiyama, Nobuhiko; Arai, Shigehisa

    2012-06-15

    An InP-based Mach-Zehnder interferometer combined with a metamaterial layer consisting of a split-ring resonator array was constructed to measure the complex permeability of the metamaterial. At a wavelength of 1.5 μm, the metamaterial showed non-unity relative permeability induced by magnetic interaction with propagating light in the device. This method of measurement would be useful to determine constitutive parameters in such waveguide-based photonic devices, allowing us to design photonic integrated circuits that make use of metamaterials.

  14. Nonunity permeability in metamaterial-based GaInAsP/InP multimode interferometers.

    PubMed

    Amemiya, T; Shindo, T; Takahashi, D; Myoga, S; Nishiyama, N; Arai, S

    2011-06-15

    We demonstrated an InP-based optical multimode interferometer (MMI) combined with metamaterials consisting of minute split-ring resonators (SRRs) arrayed on the MMI. The MMI could operate at an optical fiber communication wavelength of 1.5 μm. Magnetic resonance occurred between the SRR metamaterial and light at 1.5 μm, and the relative permeability of the metamaterial increased to 2.4 around this wavelength. This result shows that it is possible to use new materials with nonunity permeability to construct semiconductor-based photonic devices.

  15. NMR determination of porosity and permeability of western tight gas sands

    SciTech Connect

    Cowgill, D. F.; Pitman, J. K.; Seevers, D. O.

    1981-01-01

    Samples of fine-grained sandstone from the Colorado Interstate Gas Exploration (CIGE), Natural Buttes No. 21 core, Uinta Basin, Utah were studied using pulsed nuclear magnetic resonance (NMR) and standard mineralogical techniques. Brine-saturated rock porosities varied from 1 to 13% and were found deducible from the magnitude of the proton NMR. The complex pore geometry and presence of authigenic carbonate and clay minerals in these samples precluded the use of standard flow models for predicting brine permeabilities from T/sub 1/ decays. A network model of the pore system is proposed and shown capable of accurately reproducing measured rock permeabilities, which varied from 10/sup -4/ to 1 millidarcy.

  16. Thermodynamic and magnetic properties of the layered triangular magnet NaNiO2

    NASA Astrophysics Data System (ADS)

    Baker, P. J.; Lancaster, T.; Blundell, S. J.; Brooks, M. L.; Hayes, W.; Prabhakaran, D.; Pratt, F. L.

    2005-09-01

    We report muon-spin rotation, heat capacity, magnetization, and ac magnetic susceptibility measurements of the magnetic properties of the layered spin- 1/2 antiferromagnet NaNiO2 . These show the onset of long-range magnetic order below TN=19.5K . Rapid muon depolarization, persisting from TN to about 5 K above TN , is consistent with the presence of short-range magnetic order. The temperature and frequency dependence of the ac susceptibility suggests that magnetic clusters persist above 25 K and that their volume fraction decreases with increasing temperature. A frequency dependent peak in the ac magnetic susceptibility at Tsf=3K is observed, consistent with a slowing of spin fluctuations at this temperature. A partial magnetic phase diagram is deduced.

  17. ACS from development to operations

    NASA Astrophysics Data System (ADS)

    Caproni, Alessandro; Colomer, Pau; Jeram, Bogdan; Sommer, Heiko; Chiozzi, Gianluca; Mañas, Miguel M.

    2016-08-01

    The ALMA Common Software (ACS), provides the infrastructure of the distributed software system of ALMA and other projects. ACS, built on top of CORBA and Data Distribution Service (DDS) middleware, is based on a Component- Container paradigm and hides the complexity of the middleware allowing the developer to focus on domain specific issues. The transition of the ALMA observatory from construction to operations brings with it that ACS effort focuses primarily on scalability, stability and robustness rather than on new features. The transition came together with a shorter release cycle and a more extensive testing. For scalability, the most problematic area has been the CORBA notification service, used to implement the publisher subscriber pattern because of the asynchronous nature of the paradigm: a lot of effort has been spent to improve its stability and recovery from run time errors. The original bulk data mechanism, implemented using the CORBA Audio/Video Streaming Service, showed its limitations and has been replaced with a more performant and scalable DDS implementation. Operational needs showed soon the difference between releases cycles for Online software (i.e. used during observations) and Offline software, which requires much more frequent releases. This paper attempts to describe the impact the transition from construction to operations had on ACS, the solution adopted so far and a look into future evolution.

  18. Simple Equipment for Imaging AC.

    ERIC Educational Resources Information Center

    Kamata, Masahiro; Anayama, Takayuki

    2003-01-01

    Presents an effective way to demonstrate the difference between direct current and alternating current using red and green LEDs. Describes how to make a tool that shows how an AC voltage changes with time using the afterimage effect of the LEDs. (Author/NB)

  19. Lunar electrical conductivity, permeability and temperature from Apollo magnetometer experiments

    NASA Technical Reports Server (NTRS)

    Dyal, P.; Parkin, C. W.; Daily, W. D.

    1977-01-01

    Magnetometers were deployed at four Apollo sites on the moon to measure remanent and induced lunar magnetic fields. Measurements from this network of instruments were used to calculate the electrical conductivity, temperature, magnetic permeability, and iron abundance of the lunar interior. The measured lunar remanent fields range from 3 gammas minimum at the Apollo 15 site to 327 gammas maximum at the Apollo 16 site. Simultaneous magnetic field and solar plasma pressure measurements show that the remanent fields at the Apollo 12 and 16 sites interact with, and are compressed by, the solar wind. Remanent fields at Apollo 12 and Apollo 16 are increased 16 gammas and 32 gammas, respectively, by a solar plasma bulk pressure increase of 1.5 X 10 to the -7th power dynes/sq cm. Global lunar fields due to eddy currents, induced in the lunar interior by magnetic transients, were analyzed to calculate an electrical conductivity profile for the moon. From nightside magnetometer data in the solar wind it was found that deeper than 170 km into the moon the conductivity rises from .0003 mhos/m to .10 mhos/m at 100 km depth. Recent analysis of data obtained in the geomagnetic tail, in regions free of complicating plasma effects, yields results consistent with nightside values.

  20. Vascular permeability, vascular hyperpermeability and angiogenesis

    PubMed Central

    Nagy, Janice A.; Benjamin, Laura; Zeng, Huiyan; Dvorak, Ann M.

    2008-01-01

    The vascular system has the critical function of supplying tissues with nutrients and clearing waste products. To accomplish these goals, the vasculature must be sufficiently permeable to allow the free, bidirectional passage of small molecules and gases and, to a lesser extent, of plasma proteins. Physiologists and many vascular biologists differ as to the definition of vascular permeability and the proper methodology for its measurement. We review these conflicting views, finding that both provide useful but complementary information. Vascular permeability by any measure is dramatically increased in acute and chronic inflammation, cancer, and wound healing. This hyperpermeability is mediated by acute or chronic exposure to vascular permeabilizing agents, particularly vascular permeability factor/vascular endothelial growth factor (VPF/VEGF, VEGF-A). We demonstrate that three distinctly different types of vascular permeability can be distinguished, based on the different types of microvessels involved, the composition of the extravasate, and the anatomic pathways by which molecules of different size cross-vascular endothelium. These are the basal vascular permeability (BVP) of normal tissues, the acute vascular hyperpermeability (AVH) that occurs in response to a single, brief exposure to VEGF-A or other vascular permeabilizing agents, and the chronic vascular hyperpermeability (CVH) that characterizes pathological angiogenesis. Finally, we list the numerous (at least 25) gene products that different authors have found to affect vascular permeability in variously engineered mice and classify them with respect to their participation, as far as possible, in BVP, AVH and CVH. Further work will be required to elucidate the signaling pathways by which each of these molecules, and others likely to be discovered, mediate the different types of vascular permeability. PMID:18293091

  1. Pneumatic fracturing of low permeability media

    SciTech Connect

    Schuring, J.R.

    1996-08-01

    Pneumatic fracturing of soils to enhance the removal and treatment of dense nonaqueous phase liquids is described. The process involves gas injection at a pressure exceeding the natural stresses and at a flow rate exceeding the permeability of the formation. The paper outlines geologic considerations, advantages and disadvantages, general technology considerations, low permeability media considerations, commercial availability, efficiency, and costs. Five case histories of remediation using pneumatic fracturing are briefly summarized. 11 refs., 2 figs., 1 tab.

  2. Rhubarb Antagonizes Matrix Metalloproteinase-9-induced Vascular Endothelial Permeability

    PubMed Central

    Cui, Yun-Liang; Zhang, Sheng; Tian, Zhao-Tao; Lin, Zhao-Fen; Chen, De-Chang

    2016-01-01

    Background: Intact endothelial structure and function are critical for maintaining microcirculatory homeostasis. Dysfunction of the latter is an underlying cause of various organ pathologies. In a previous study, we showed that rhubarb, a traditional Chinese medicine, protected intestinal mucosal microvascular endothelial cells in rats with metastasizing septicemia. In this study, we investigated the effects and mechanisms of rhubarb on matrix metalloproteinase-9 (MMP9)-induced vascular endothelial (VE) permeability. Methods: Rhubarb monomers were extracted and purified by a series of chromatography approaches. The identity of these monomers was analyzed by hydrogen-1 nuclear magnetic resonance (NMR), carbon-13 NMR, and distortionless enhancement by polarization transfer magnetic resonance spectroscopy. We established a human umbilical vein endothelial cell (HUVEC) monolayer on a Transwell insert. We measured the HUVEC permeability, proliferation, and the secretion of VE-cadherin into culture medium using fluorescein isothiocyanate-dextran assay, 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2-H-tetrazolium bromide assay, and enzyme-linked immunosorbent assay, respectively, in response to treatment with MMP9 and/or rhubarb monomers. Results: A total of 21 rhubarb monomers were extracted and identified. MMP9 significantly increased the permeability of the HUVEC monolayer, which was significantly reduced by five individual rhubarb monomer (emodin, 3,8-dihydroxy-1-methyl-anthraquinone-2-carboxylic acid, 1-O-caffeoyl-2-(4-hydroxyl-O-cinnamoyl)-β-D-glucose, daucosterol linoleate, and rhein) or a combination of all five monomers (1 μmol/L for each monomer). Mechanistically, the five-monomer mixture at 1 μmol/L promoted HUVEC proliferation. In addition, MMP9 stimulated the secretion of VE-cadherin into the culture medium, which was significantly inhibited by the five-monomer mixture. Conclusions: The rhubarb mixture of emodin, 3,8-dihydroxy-1-methyl-anthraquinone-2

  3. Simulating perforation permeability damage and cleanup

    SciTech Connect

    Morris, J P; Lomov, I N; Glenn, L A

    2000-12-15

    Completion of cased and cemented wells by shaped charge perforation causes its own damage to the formation, potentially reducing well productivity. In practice it is found that underbalance conditions clean up the damaged zone to some extent, however, the mechanisms of these processes are poorly understood. Most hydrocodes typically used to simulate rock response to shaped charge penetration do not provide permeability estimates. Furthermore, the time scales for formation clean up are potentially much longer than the period of jet penetration. We have developed a simple, yet accurate model for the evolution of porosity and permeability which can easily be incorporated into existing hydrocodes using information from the history of each cell. In addition, we have developed a code that efficiently simulates fines migration during the post-shot surge period using initial conditions taken directly from hydrocode simulations of jet penetration. Results from a one-dimensional model simulation are in excellent agreement with measured permeability distributions. We also present two-dimensional numerical results which qualitatively reproduce experimentally obtained permeability maps for different values of underbalance. Although initial results have been promising, further comparison with experiment is essential to tune the coupling between the hydrocode and fines migration simulator. Currently the permeability model is most appropriate for high permeability sandstones (such as Berea), but with little effort, the model can be extended to other rock types, given sufficient experimental data.

  4. Fracture-permeability behavior of shale

    SciTech Connect

    Carey, J. William; Lei, Zhou; Rougier, Esteban; Mori, Hiroko; Viswanathan, Hari

    2015-05-08

    The fracture-permeability behavior of Utica shale, an important play for shale gas and oil, was investigated using a triaxial coreflood device and X-ray tomography in combination with finite-discrete element modeling (FDEM). Fractures generated in both compression and in a direct-shear configuration allowed permeability to be measured across the faces of cylindrical core. Shale with bedding planes perpendicular to direct-shear loading developed complex fracture networks and peak permeability of 30 mD that fell to 5 mD under hydrostatic conditions. Shale with bedding planes parallel to shear loading developed simple fractures with peak permeability as high as 900 mD. In addition to the large anisotropy in fracture permeability, the amount of deformation required to initiate fractures was greater for perpendicular layering (about 1% versus 0.4%), and in both cases activation of existing fractures are more likely sources of permeability in shale gas plays or damaged caprock in CO₂ sequestration because of the significant deformation required to form new fracture networks. FDEM numerical simulations were able to replicate the main features of the fracturing processes while showing the importance of fluid penetration into fractures as well as layering in determining fracture patterns.

  5. Fracture-permeability behavior of shale

    DOE PAGES

    Carey, J. William; Lei, Zhou; Rougier, Esteban; ...

    2015-05-08

    The fracture-permeability behavior of Utica shale, an important play for shale gas and oil, was investigated using a triaxial coreflood device and X-ray tomography in combination with finite-discrete element modeling (FDEM). Fractures generated in both compression and in a direct-shear configuration allowed permeability to be measured across the faces of cylindrical core. Shale with bedding planes perpendicular to direct-shear loading developed complex fracture networks and peak permeability of 30 mD that fell to 5 mD under hydrostatic conditions. Shale with bedding planes parallel to shear loading developed simple fractures with peak permeability as high as 900 mD. In addition tomore » the large anisotropy in fracture permeability, the amount of deformation required to initiate fractures was greater for perpendicular layering (about 1% versus 0.4%), and in both cases activation of existing fractures are more likely sources of permeability in shale gas plays or damaged caprock in CO₂ sequestration because of the significant deformation required to form new fracture networks. FDEM numerical simulations were able to replicate the main features of the fracturing processes while showing the importance of fluid penetration into fractures as well as layering in determining fracture patterns.« less

  6. A multistep ac electrodeposition method to prepare Co nanowires with high coercivity

    NASA Astrophysics Data System (ADS)

    Wang, Pangpang; Gao, Lumei; Qiu, Zhiyong; Song, Xiaoping; Wang, Liqun; Yang, Sen; Murakami, Ri-ichi

    2008-09-01

    It is known that the ac electrodeposition method with low current density can grow compact metal nanowires, but the length of those nanowires is very short. In contrast, the ac electrodeposition method with high current density can grow long metal nanowires. However these long nanowires are not compact and contain lots of defects. In this paper, we describe a multistep ac electrodeposition method to fabricate long metal nanowires with compact structure uniformly filled upon a porous anodic aluminum oxide template. Using this method, Co nanowires with high coercivity (Hc ∥) and remnant ratio (Mr/Ms) have been prepared under relatively low deposition current density. The Co nanowires exhibited obvious magnetic anisotropy with the easy axis along the axial direction of nanowires. The maximal Hc ∥ (2900 Oe) and Mr/Ms (0.95) were optimal for the perpendicular magnetic recording materials. The magnetic microstructure of Co nanowires is also discussed in this paper.

  7. AC Susceptibility of the Dipolar Spin Ice Dy2Ti2O7: Experiments and Monte Carlo Simulations

    NASA Astrophysics Data System (ADS)

    Takatsu, Hiroshi; Goto, Kazuki; Otsuka, Hiromi; Higashinaka, Ryuji; Matsubayashi, Kazuyuki; Uwatoko, Yoshiya; Kadowaki, Hiroaki

    2013-10-01

    Experimental data of the frequency-dependent ac susceptibility [χac(ω)] for the dipolar spin ice Dy2Ti2O7 has been analyzed by Monte Carlo simulations on the basis of the single-spin-flip Metropolis algorithm. We have directly evaluated χac(ω) by applying an ac magnetic field. We found that this simulation reasonably reproduces the experimental behavior of χac(ω) in the temperature range from 0.6 to 1.0 K, where dilute magnetic monopoles diffusively move. The conversion factor from simulation time to real time, i.e., the rate of hopping of monopoles to nearest-neighbor sites, strongly depends on temperature.

  8. Comparative field permeability measurement of permeable pavements using ASTM C1701 and NCAT permeameter methods.

    PubMed

    Li, Hui; Kayhanian, Masoud; Harvey, John T

    2013-03-30

    Fully permeable pavement is gradually gaining support as an alternative best management practice (BMP) for stormwater runoff management. As the use of these pavements increases, a definitive test method is needed to measure hydraulic performance and to evaluate clogging, both for performance studies and for assessment of permeability for construction quality assurance and maintenance needs assessment. Two of the most commonly used permeability measurement tests for porous asphalt and pervious concrete are the National Center for Asphalt Technology (NCAT) permeameter and ASTM C1701, respectively. This study was undertaken to compare measured values for both methods in the field on a variety of permeable pavements used in current practice. The field measurements were performed using six experimental section designs with different permeable pavement surface types including pervious concrete, porous asphalt and permeable interlocking concrete pavers. Multiple measurements were performed at five locations on each pavement test section. The results showed that: (i) silicone gel is a superior sealing material to prevent water leakage compared with conventional plumbing putty; (ii) both methods (NCAT and ASTM) can effectively be used to measure the permeability of all pavement types and the surface material type will not impact the measurement precision; (iii) the permeability values measured with the ASTM method were 50-90% (75% on average) lower than those measured with the NCAT method; (iv) the larger permeameter cylinder diameter used in the ASTM method improved the reliability and reduced the variability of the measured permeability.

  9. Impedance match of long-wavelength electromagnetic waves incident into magnetic photonic crystals.

    PubMed

    Yang, S Y

    2007-06-11

    By utilizing an effective-medium method, the effective dielectric constant and effective magnetic permeability of magnetic photonic crystals at long-wavelength limits were calculated. We also examined the impedance ratio when a long-wavelength electromagnetic wave is incident to a magnetic photonic crystal. In this work, we focus on investigating the impact of the magnetic permeability of rods forming magnetic photonic crystals on the impedance ratio. Furthermore, we analyze the dependencies of the incident angle at impedance match on the magnetic permeability and filling factor of rods.

  10. Measurements of AC Losses and Current Distribution in Superconducting Cables

    SciTech Connect

    Nguyen, Doan A; Ashworth, Stephen P; Duckworth, Robert C; Carter, Bill; Fleshler, Steven

    2011-01-01

    This paper presents our new experimental facility and techniques to measure ac loss and current distribution between the layers for High Temperature Superconducting (HTS) cables. The facility is powered with a 45 kVA three-phase power supply which can provide three-phase currents up to 5 kA per phase via high current transformers. The system is suitable for measurements at any frequency between 20 and 500 Hz to better understand the ac loss mechanisms in HTS cables. In this paper, we will report techniques and results for ac loss measurements carried out on several HTS cables with and without an HTS shielding layer. For cables without a shielding layer, care must be taken to control the effect of the magnetic fields from return currents on loss measurements. The waveform of the axial magnetic field was also measured by a small pick-up coil placed inside a two-layer cable. The temporal current distribution between the layers can be calculated from the waveform of the axial field.

  11. Proppant effects on maintaining fracture permeability in shale.

    NASA Astrophysics Data System (ADS)

    Ingraham, M. D.; Bauer, S. J.; Bolintineanu, D.; Rao, R. R.; Lechman, J. B.; Romero, J. A.

    2014-12-01

    A series of tests have been performed on manually fractured and propped shale. The shale used in this study contained 5-10% porosity, and 10-40% clay. Samples were fractured subparallel to bedding. Quartz sand (0.60-0.85 mm) was used as a proppant; proppant was manually placed on a fracture surface, resulting in a monolayer with random distribution. The specimens were repeatedly subjected to reservoir conditions, 20.7 MPa confining, 6.9 MPa differential stress, and temperature of 75 C. System permeability was measured during testing by flowing DI water through the specimen, flow rates were set to 0.002 ml/min, with the downstream vented to atmosphere. Upstream pressure varied to maintain the flow rate, and was approximately 1.4 MPa in the most recent (lowest permeability) test. Between test periods, specimens were removed from the test system and scanned with x-ray μCT. There is significant decrease in flow with subsequent testing due fracture closure. This is attributed to observations of clay swelling, proppant embedment, proppant fracture and shale wall sloughing. These lead to a decrease in effective fracture aperture. Flow induced particle transport clogs flow paths and impedes flow. Isolated grains tend to crush whereas continuous grains in proppant patches tend fracture with little displacement and tend towards embedment. Corresponding numerical simulations are underway to capture the change in crack flow due to these mechanisms. Images from the CT scans of the proppant filled crack are segmented and meshed. Then flow simulations are performed via the finite element method. Preliminary results are discussed. This work is a precursor to laboratory-scale shale fracture and proppant testing; cores will be hydraulically fractured and propped with appropriate proppant and fluid rheology. Proppant life and permeability reduction will be monitored and specimens will be scanned with μCT. Tests will be used to inform proppant flow models which seek to model

  12. Permeability reduction in granite under hydrothermal conditions

    USGS Publications Warehouse

    Morrow, C.A.; Moore, Diane E.; Lockner, D.A.

    2001-01-01

    The formation of impermeable fault seals between earthquake events is a feature of many models of earthquake generation, suggesting that earthquake recurrence may depend in part on the rate of permeability reduction of fault zone materials under hydrothermal conditions. In this study, permeability measurements were conducted on intact, fractured, and gouge-bearing Westerly granite at an effective pressure of 50 MPa and at temperatures from 150?? to 500??C, simulating conditions in the earthquake-generating portions of fault zones. Pore fluids were cycled back and forth under a 2 MPa pressure differential for periods of up to 40 days. Permeability of the granite decreased with time t, following the exponential relation k = c(10-rt). For intact samples run between 250?? and 500??C the time constant for permeability decrease r was proportional to temperature and ranged between 0.001 and 0.1 days-1 (i.e., between 0.4 and 40 decades year-1 loss of permeability). Values of r for the lower-temperature experiments differed little from the 250??C runs. In contrast, prefractured samples showed higher rates of permeability decrease at a given temperature. The surfaces of the fractured samples showed evidence of dissolution and mineral growth that increased in abundance with both temperature and time. The experimentally grown mineral assemblages varied with temperature and were consistent with a rock-dominated hydrothermal system. As such mineral deposits progressively seal the fractured samples, their rates of permeability decrease approach the rates for intact rocks at the same temperature. These results place constraints on models of precipitation sealing and suggest that fault rocks may seal at a rate consistent with earthquake recurrence intervals of typical fault zones.

  13. ac-resistance-measuring instrument

    SciTech Connect

    Hof, P.J.

    1981-04-22

    An auto-ranging ac resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an ac excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance.

  14. Strain-dependent permeability of volcanic rocks.

    NASA Astrophysics Data System (ADS)

    Farquharson, Jamie; Heap, Michael; Baud, Patrick

    2016-04-01

    We explore permeability evolution during deformation of volcanic materials using a suite of rocks with varying compositions and physical properties (such as porosity ϕ). 40 mm × 20 mm cylindrical samples were made from a range of extrusive rocks, including andesites from Colima, Mexico (ϕ˜0.08; 0.18; 0.21), Kumamoto, Japan (ϕ˜0.13), and Ruapehu, New Zealand (ϕ˜0.15), and basalt from Mt Etna, Italy (ϕ˜0.04). Gas permeability of each sample was measured before and after triaxial deformation using a steady-state benchtop permeameter. To study the strain-dependence of permeability in volcanic rocks, we deformed samples to 2, 3, 4, 6, and 12 % axial strain at a constant strain rate of 10-5 s-1. Further, the influence of failure mode - dilatant or compactant - on permeability was assessed by repeating experiments at different confining pressures. During triaxial deformation, porosity change of the samples was monitored by a servo-controlled pore fluid pump. Below an initial porosity of ˜0.18, and at low confining pressures (≤ 20 MPa), we observe a dilatant failure mode (shear fracture formation). With increasing axial strain, stress is accommodated by fault sliding and the generation of ash-sized gouge between the fracture planes. In higher-porosity samples, or at relatively higher confining pressures (≥ 60 MPa), we observe compactant deformation characterised by a monotonous decrease in porosity with increasing axial strain. The relative permeability k' is given by the change in permeability divided by the initial reference state. When behaviour is dilatant, k' tends to be positive: permeability increases with progressive deformation. However, results suggest that after a threshold amount of strain, k' can decrease. k' always is negative (permeability decreases during deformation) when compaction is the dominant behaviour. Our results show that - in the absence of a sealing or healing process - the efficiency of a fault to transmit fluids is correlated to

  15. Copper vs. iron: Microwave magnetism in the metamaterial age

    NASA Astrophysics Data System (ADS)

    Acher, Olivier

    2009-07-01

    It is now well established that metamaterials based on copper patterns can exhibit significant permeability levels, but can such materials outdo conventional magnetic materials? In the case where permeability levels and bandwidth are the key figures-of-merit, it is acknowledged that copper-based metamaterials can exceed the performance of ferrites at operating frequencies above 10 GHz. As for low-frequency operation, magnetic metamaterials may also be preferred to conventional magnetic materials when requirements include excellent temperature stability or immunity to external magnetic fields. However, in many cases, metamaterials need to include certain conventional magnetic constituents in order to compete with conventional magnetic materials.

  16. Simultaneous distribution of AC and DC power

    DOEpatents

    Polese, Luigi Gentile

    2015-09-15

    A system and method for the transport and distribution of both AC (alternating current) power and DC (direct current) power over wiring infrastructure normally used for distributing AC power only, for example, residential and/or commercial buildings' electrical wires is disclosed and taught. The system and method permits the combining of AC and DC power sources and the simultaneous distribution of the resulting power over the same wiring. At the utilization site a complementary device permits the separation of the DC power from the AC power and their reconstruction, for use in conventional AC-only and DC-only devices.

  17. Comparison of Steady State Method and Transient Methods for Water Permeability Measurement in Low Permeability Rocks

    NASA Astrophysics Data System (ADS)

    Boulin, P. F.; Bretonnier, P.; Gland, N.

    2010-12-01

    Very low permeability geomaterials (order of nanoDarcy (10-21 m2)), such as clays rocks, are studied for many industrial applications such as production from unconventional reserves of oil and gas, CO2 geological storage and deep geological disposal of high-level long-lived nuclear wastes. For these last two applications, clay efficiency as barrier relies mainly on their very low permeability. Laboratory measurement of low permeability to water (below 10-19 m2) remains a technical challenge. Some authors argue that steady state methods are irrelevant due to the time required to stabilize water fluxes in such low permeability media. Most of the authors measuring low permeabilities use a transient technique called pulse decay. This study aims to compare objectively these different types of permeability tests performed on a single clay sample. For the steady state method, a high precision pump was used to impose a pressure gradient and to measure the small resulting water flow rate at steady state. We show that with a suitable set-up, the steady state method enables to measure a very low permeability of 8 10-22 m2 in a period of three days. For a comparable duration, the pulse decay test, most commonly used for such low permeability measurements, provides only an average estimate of the permeability. Permeability measurements by pulse decay require to perform simulations to interpret the pressure relaxation signals. Many uncertainties remain such as the determination of the reservoirs storage factor, micro leakage effect, or the determination of the initial pulse pressure. All these uncertainties have a very significant impact on the determination of sample permeability and specific storage. Opposite to the wide-spread idea that transient techniques are required to measure very low permeability, we show that direct steady state measurement of water permeability with suitable equipments can be much faster and more accurate than measurement by pulse decay, especially in

  18. Reactive Transport Modeling of CO2-induced Porosity and Permeability Changes in Heterogeneous Carbonate Rocks

    NASA Astrophysics Data System (ADS)

    Hao, Y.; Smith, M. M.; Mason, H. E.; Carroll, S.

    2015-12-01

    It has long been appreciated that chemical interactions have a major effect on rock porosity and permeability evolution and may alter the behavior or performance of both natural and engineered reservoir systems. Such reaction-induced permeability evolution is of particular importance for geological CO2 sequestration and storage associated with enhanced oil recovery. In this study we used a three-dimensional Darcy scale reactive transport model to simulate CO2 core flood experiments in which the CO2-equilibrated brine was injected into dolostone cores collected from the Arbuckle carbonate reservoir, Wellington, Kansas. Heterogeneous distributions of macro pores, fractures, and mineral phases inside the cores were obtained from X-ray computed microtomography (XCMT) characterization data, and then used to construct initial model macroscopic properties including porosity, permeability, and mineral compositions. The reactive transport simulations were performed by using the Nonisothermal Unsaturated Flow and Transport (NUFT) code, and their results were compared with experimental data. It was observed both experimentally and numerically that the dissolution fronts became unstable in highly heterogeneous and less permeable formations, leading to the development of highly porous flow paths or wormholes. Our model results indicate that the continuum-scale reactive transport models are able to adequately capture the evolution of distinct dissolution fronts as observed in carbonate rocks at a core scale. The impacts of rock heterogeneity, chemical kinetics and porosity-permeability relationships were also examined in this study. The numerical model developed in this study will not only help improve understanding of coupled physical and chemical processes controlling carbonate dissolution, but also provide a useful basis for upscaling transport and reaction properties from core scale to field scale. This work was performed under the auspices of the U.S. Department of Energy

  19. Noise modeling from high-permeability shields using Kirchhoff equations

    SciTech Connect

    Sandin, Henrik J; Volegov, Petr L; Espy, Michelle A; Matlashov, Andrei N; Savukov, Igor M; Schultz, Larry J

    2010-01-01

    Progress in the development of high-sensitivity magnetic-field measurements has stimulated interest in understanding magnetic noise of conductive materials, especially of magnetic shields (DC or rf) based on high-permeability materials and/or high-conductivity materials. For example, SQUIDs and atomic magnetometers have been used in many experiments with mu-metal shields, and additionally SQUID systems frequently have rf shielding based on thin conductive materials. Typical existing approaches to modeling noise only work with simple shield and sensor geometries while common experimental setups today consist of multiple sensor systems arbitrary shapes and complex shield geometries. With complex sensor arrays used in, for example, MEG and Ultra Low Field MRI studies the knowledge of the noise correlation between sensors is as important as the knowledge of the noise itself. This is crucial for incorporating efficient noise cancelation schemes for the system. We developed an approach that allows us to calculate the Johnson noise for any geometrically shaped shield and multiple sensor systems. The approach uses a fraction of the processing power of other approaches and with a multiple sensor system our approach not only calculates the noise for each sensor but it also calculates the noise correlation matrix between sensors. Here we will show the algorithm and examples where it can be implemented.

  20. [Use of rigid gas permeable contact lenses].

    PubMed

    Habela, M

    1992-01-01

    By application of contact lenses destined for a extended wearing, for preservation of a normal structure and metabolism of the cornea a considerable permeability of the contact lens for oxygen is necessary (Dk/L 75-80). The actually most popular in the world soft contact lenses have no such parameters. The application of rigid lenses produced from materials of high permeability for oxygen enables the extended wearing without substantial disturbances of the corneal metabolism. The paper presents a new generation of fluoro-silicone acrylates used for the production of contact lenses permeable for oxygen. Discussed are the problems connected with the adjusting of these lenses, their tolerance and influence on the corneal metabolism.

  1. Blood flow and permeability in microvessels

    NASA Astrophysics Data System (ADS)

    Sugihara-Seki, Masako; Fu, Bingmei M.

    2005-07-01

    The mechanics of blood flow in microvessels and microvessel permeability are reviewed. In the first part, characteristics of blood flow in vivo and in vitro are described from a fluid-mechanical point of view, and mathematical models for blood flow in microvessels are presented. Possible causes of the increased flow resistance obtained in vivo compared to in vitro are examined, including the effects of irregularities of vessel lumen, the presence of endothelial surface glycocalyx and white blood cells. In the second part, the ultrastructural pathways and mechanisms whereby endothelial cells and the clefts between the cells modulate microvessel permeability to water and solutes are introduced. Previous and current models for microvessel permeability to water and solutes are reviewed. These models examine the role of structural components of interendothelial cleft, such as junction strands and surface glycocalyx, in the determination of water and solute transport across the microvessel walls. Transport models in the tissue space surrounding the microvessel are also described.

  2. Transient and steady-state relative permeabilities from two-phase flow experiments in planar pore networks

    NASA Astrophysics Data System (ADS)

    Tsakiroglou, C. D.; Avraam, D. G.; Payatakes, A. C.

    2007-09-01

    The water krw and oil kro relative permeability curves of a glass-etched planar pore network are estimated with history matching from transient displacement experiments performed at varying values of the capillary number, Ca, for two fluid systems: one of intermediate and one of strong wettability. The transient k,k are compared to corresponding ones measured with the steady-state method on the same porous medium [Avraam DG, Payatakes AC. Flow regimes and relative permeabilities during steady-state two-phase flow in porous media. J Fluid Mech 1995;293:207-36; Avraam DG, Payatakes AC. Generalized relative permeability coefficients during steady-state two-phase flow in porous media and correlation with the flow mechanisms. Transport Porous Med 1995;20:135-68; Avraam DG, Payatakes AC. Flow mechanisms, relative permeabilities, and coupling effects in steady-state two-phase flow through porous media. The case of strong wettability. Ind Eng Chem Res 1999;38:778-86.], and potential differences from them are interpreted in the light of the differences between the transient growth pattern, and the steady-state two-phase flow regime. For intermediate wettability, the transient kro and krw exceed the corresponding steady-state functions at low Ca values and have the tendency to become smaller than the steady-state ones at high Ca values. For strong wettability, the transient kro and krw are increasing functions of Ca, the transient kro is higher than the steady-state one, whereas the transient krw decreases substantially and becomes lower than the steady-state one at low Ca values. The dynamic capillary pressure estimated from transient experiments is a decreasing function of Ca in agreement with previous theoretical and experimental studies.

  3. Development of an Improved Permeability Modification Simulator

    SciTech Connect

    Gao, H.W.; Elphnick, J.

    1999-03-09

    This report describes the development of an improved permeability modification simulator performed jointly by BDM Petroleum Technologies and Schlumberger Dowell under a cooperative research and development agreement (CRADA) with the US Department of Energy. The improved simulator was developed by modifying NIPER's PC-GEL permeability modification simulator to include a radial model, a thermal energy equation, a wellbore simulator, and a fully implicit time-stepping option. The temperature-dependent gelation kinetics of a delayed gel system (DGS) is also included in the simulator.

  4. Immediate refitting with gas permeable lenses.

    PubMed

    Bennett, E S

    1983-03-01

    Handling long-term polymethylmethacrylate (PMMA) lens wearers, especially those suffering severe corneal oxygen deprivation, has been a problem much relieved by the introduction of oxygen permeable rigid lenses. Previous methods including lens modifications, discontinuation of lens wear, and de-adaptation possessed limitations which could cause the patient to experience permanent corneal curvature and refractive changes. Immediately refitting these patients with gas permeable lenses has been a procedure which appears to have eliminated many of the previous problems and has achieved rapid approval from contact lens practitioners the past few years. This paper discusses how this procedure can be performed to the satisfaction of both the optometrist and the patient.

  5. Flexibility of hard gas permeable contact lenses.

    PubMed

    Stevenson, R W

    1988-11-01

    Gas permeable (GP) lenses can flex on some eyes producing unpredictable clinical results. A method of measuring the flexibility of hard GP materials has been developed and shown to be repeatable. Materials in the form of flats rather than lenses were used. Differences between materials were found and in general a linear relation was shown to exist between maximum flexing and quoted oxygen permeability (r = 0.78, p less than 0.05). It is recommended that flexibility be measured and reported in the data presented with all new GP polymers. The term "hard" rather than "rigid" in describing GP lenses is suggested.

  6. Phase-Sensitive Detection of Spin Pumping via the ac Inverse Spin Hall Effect

    NASA Astrophysics Data System (ADS)

    Weiler, Mathias; Shaw, Justin M.; Nembach, Hans T.; Silva, Thomas J.

    2014-10-01

    We use a phase-sensitive, quantitative technique to separate inductive and ac inverse spin Hall effect (ISHE) voltages observed in Ni81Fe19/normal metal multilayers under the condition of ferromagnetic resonance. For Ni81Fe19/Pt thin film bilayers and at microwave frequencies from 7 to 20 GHz, we observe an ac ISHE magnitude that is much larger than that expected from the dc spin Hall angle ΘSHPt=0.1. Furthermore, at these frequencies, we find an unexpected, ≈110° phase of the ac ISHE signal relative to the in-plane component of the resonant magnetization precession. We attribute our findings to a dominant intrinsic ac ISHE in Pt.

  7. Granular composites containing ``micro-onions,'' permeability, and permittivity calculated for application to microwave absorbers

    NASA Astrophysics Data System (ADS)

    Abe, M.; Kuroda, J.; Matsumoto, M.

    2002-05-01

    The formula for the effective permeability <μ> (or permittivity <ɛ>) is derived, based on the Maxwell Garnett approximation, for the granular composites having "micro-onions" (micron-meter-sized, multifold core-shell structured particles) dispersed in matrices. We calculated <μ> and <ɛ> up to 3 GHz for the composites in which micro-onions of threefold [i.e., air/(silica+air)/NiZn-ferrite or water/(silica+water)/NiZn-ferrite] structure are dispersed in a Fe/silicon-rubber matrix. Introducing the micro-onions into the Fe/silicon-rubber matrix improves the wave absorber characteristics, increasing absorption and decreasing reflection, at 0.5-3 GHz. Confining the magnetic substance to the outermost shell layers increases the natural ferromagnetic resonance frequency, thus enhancing permeability at high frequencies. It also facilitates fabrication of lightweight electromagnetic wave absorbers, and suppresses eddy current loss in case the magnetic substance is a metal.

  8. Permeability assessment of poorly water-soluble compounds under solubilizing conditions: the reciprocal permeability approach.

    PubMed

    Katneni, Kasiram; Charman, Susan A; Porter, Christopher J H

    2006-10-01

    The objective of this study was to develop a general method to assess the intestinal permeability of poorly water-soluble drugs where low-aqueous drug solubility requires conduct of experiments under solubilizing experimental conditions. The permeability (Papp) of diazepam (DIA) was assessed across excised rat jejunum in the absence (Pappcontrol) and presence (Pappuncorr) of polysorbate-80 (PS-80). The micellar association constant (Ka) of DIA, estimated via equilibrium solubility studies, was used to correct Pappuncorr data and obtain an estimate of the true permeability coefficient (Pappcorr). An alternate approach was also developed (the reciprocal permeability approach) to allow direct estimation of Pappcorr without the need for independent estimation of Ka. The approach was further examined experimentally using a range of model drugs. DIA Pappcorr values obtained using the Ka from equilibrium solubility studies deviated from Papp(control) values, especially at PS-80 concentrations above 0.1% w/v. In contrast, data obtained using the reciprocal permeability method were consistent with Pappcontrol across the PS-80 concentration range. Similar trends were observed with propranolol (PRO), antipyrine (ANT), naproxen (NAP), and cinnarizine (CIN). The reciprocal permeability approach therefore provides a simple and accurate method by which the permeability of poorly water-soluble compounds may be estimated under solubilizing conditions.

  9. Comparative study of structure and magnetic properties of micro- and nano-sized GdxY3-xFe5O12 garnet

    NASA Astrophysics Data System (ADS)

    Sattar, A. A.; Elsayed, H. M.; Faramawy, A. M.

    2016-08-01

    Gadolinium Yttrium Iron garnet (GdYIG) samples with the chemical formula (GdxY3-xFe5O12) (x=0.0, 0.25, 0.5, 0.75, and 1.0) were prepared via two different methods, the standard ceramic method (SC) and the co-precipitation method (CP). The effect of preparation conditions and Gd3+ ion substitution on the phase formation, crystal structure, morphology and magnetic properties were studied. Moreover, the initial permeability μi and Curie temperature Tc were measured for all investigated samples. It was found that, the lattice parameter increases on addition of Gd3+ ion while the porosity decreases for both systems of samples. The crystallite sizes of the samples prepared by the (CP) method are smaller than those prepared by (SC) method. The magnetization Ms decreases while the coercivity Hc increases by increasing the Gd+3 concentration in both systems of samples. For the samples prepared by the (SC) method the values of Ms are higher than those prepared by (CP) method. Also, it was found that the initial permeability μi and Curie temperature Tc are higher in samples prepared by (SC) method than those prepared by (CP) method. Moreover the magnetic loss (the rate of temperature raise (ΔT/Δt) in an AC magnetic field) was measured for all investigated samples, which increased with increasing Gd concentration. Furthermore, it was found that the samples prepared by (SC) method have magnetic loss higher than those prepared by (CP) method. It was concluded that the preparation method has great effects on the magnetic properties of GdYIG ferrite. The obtained results were explained in the light of Neel's model.

  10. Experimental and analytical modeling of resonant permittivity and permeability in ferroelectric-ferrite composites in microwave range

    NASA Astrophysics Data System (ADS)

    Ciomaga, Cristina E.; Balmus, Sorin B.; Dumitru, Ioan; Mitoseriu, Liliana

    2012-06-01

    The ferroelectric-magnetic composite materials are very suitable for designing and producing microwave devices and components, due to their dielectric and magnetic properties. For microwave antennas, sensors, resonators, oscillators, filters, phase shifters, attenuators, and amplifiers, the output and input impedances, the resonance frequencies, the quality factor (the losses), and the attenuation or the amplification can be very easily adjusted by modifying the dielectric permittivity or/and the magnetic permeability. This is possible by a right choice of the ratio between the ferroelectric and magnetic phases in the composite material. Therefore, it is highly important to accurately determine these characteristics of the composite material in microwave range.

  11. Greatly enhanced azimuthal permeability of a ferrite core with a wire coil metamaterial

    NASA Astrophysics Data System (ADS)

    Li, Z. W.; Huang, R. F.; Kong, L. B.

    2009-04-01

    Metamaterial has been developed using a structure of Cu-wire coil wound on a ferrite core. The metamaterial has greatly enhanced azimuthal permeability, as compared to the mere core material, and its resonance frequency can be controlled through varying the number of turns of the coil. These special properties, which are significantly different from general magnetic material, can be understood by an equivalent lumped parameter model.

  12. AC Inductive Measurement of Intergrain and Intragrain Currents in High-Tc Oxide Superconductors

    NASA Astrophysics Data System (ADS)

    Ni, Baorong; Munakata, Toshiyuki; Matsushita, Teruo; Iwakuma, Masataka; Funaki, Kazuo; Takeo, Masakatsu; Yamafuji, Kaoru

    1988-09-01

    Bulk intergrain current and closed intragrain current in sintered Y-Ba-Cu-O superconductors were measured at 77 K by using an ac inductive method. These currents can be separated because of the large difference in penetrating rates of the magnetic flux into specimens with respect to the ac field amplitude. The obtained intergrain current density agreed approximately with critical current density measured resistively. The closed intragrain current density amounted to 4.3× 108 A/m2 at B{=}0.5 T and decreased gradually with increasing magnetic field. The present results show that the ac inductive measurement is one of the available nondestructive methods to characterize sintered oxide specimens.

  13. AC losses of single-core MgB2 wires with different metallic sheaths

    NASA Astrophysics Data System (ADS)

    Kováč, J.; Šouc, J.; Kováč, P.; Hušek, I.

    2015-12-01

    AC losses of single-core MgB2 superconductors with different metallic sheaths (Cu, GlidCop, stainless steel and Monel) have been measured and analyzed. These wires were exposed to external magnetic field with frequencies 72 and 144 Hz and amplitudes up to 0.1 T at temperatures ranged from 18 to 40 K. The obtained results have shown that applied metallic sheath can affect the measured AC loss considerably. In the case of GlidCop and Stainless Steel a negligible small effect of metallic sheath was observed. Strong contribution of eddy currents has been found in the wire with well conductive copper sheath. In the case of Monel sheath, the hysteresis loss of magnetic sheath is dominated and AC loss of MgB2 core is practically not visible.

  14. Permeable pavement research – Edison, New Jersey

    EPA Science Inventory

    These are the slides for the New York City Concrete Promotional Council Pervious Concrete Seminar presentation. The basis for the project, the monitoring design and some preliminary monitoring data from the permeable pavement parking lot at the Edison Environmental Center are pre...

  15. Alterations in Intestinal Permeability After Thermal Injury,

    DTIC Science & Technology

    1992-01-01

    disaccharide with a The cause of the altered intestinal permeability in our molecular weight of 342, and mannitol, a monosaccharide patients who...and linear regression analyses were used as indicated. Differences •P<.01 vs controls and uninfected patients by analysis of were considered

  16. Prolactin and blood-brain barrier permeability.

    PubMed

    Rosas-Hernandez, Hector; Cuevas, Elvis; Lantz, Susan M; Hamilton, W Ryan; Ramirez-Lee, Manuel A; Ali, Syed F; Gonzalez, Carmen

    2013-11-01

    The blood-brain barrier (BBB) consists in part of a highly specialized set of cells which separates the brain from the vascular system. The BBB controls the entry and exit of substances from the brain tissue through tight junctions (TJs) between endothelial cells. It is known that the hormone prolactin (PRL) is able to regulate endothelial-dependent processes, like the balance between proliferation and apoptosis and the mammary epithelial permeability. However, the effects of PRL and the role it plays in the BBB permeability are still not well understood. A primary culture of bovine brain microvessel endothelial cells was used as in vitro model of BBB. Cells were treated with PRL (0.1, 1, 10 and 100 nM) for 24 hours. PRL significantly increased cellular proliferation at 10 and 100 nM, but did not modify basal apoptosis. These effects were dependent on the production of the mitogenic factor nitric oxide (NO). PRL significantly decreased the permeability and promoted an increase in trans-endothelial electrical resistance in a NO-independent way. PRL also increased the expression of the TJs proteins claudin-5 and occludin. The short form of the PRL receptor was detected in these cells but its expression was not modified by PRL. Together, these results suggest that PRL has the ability to increase cellular proliferation associated with a decrease on BBB permeability by increasing the expression of TJs proteins.

  17. Pump and treat in low permeability media

    SciTech Connect

    Mackay, D.M.

    1996-08-01

    Pump and Treat (P&T) is a commonly applied technology whose primary promise for the low permeability environments of interest to these technology reviews is almost certainly containment of the problem. Conventional P&T would be expected to offer little promise of complete restoration in such environments, unless very long time frames (decades or centuries) are considered. A variety of approaches have been proposed to enhance the efficiency of P&T; some appear to offer little promise in low or mixed permeability environments, while others may offer more promise (e.g. hydro- or pneumatic-fracturing, which are described elsewhere in this document, and application of vacuum to the extraction well(s), which is a proprietary technology whose promise is currently difficult to assess objectively). Understanding the potential advantages and means of optimizing these enhancement approaches requires more understanding of the basic processes limiting P&T performance in low or mixed permeability media. These efforts are probably also necessary to understand the advantages and means of optimizing many of the very different remedial technologies that may be applicable to low or mixed permeability environments. Finally, since a reasonably certain capability of P&T is containment (i.e. prevention of further migration of contaminants), P&T may generally be required as a sort of safety net around sites at which the alternative technologies are being tested or applied. 23 refs.

  18. EVALUATION OF PERMEABLE REACTIVE BARRIER PERFORMANCE

    EPA Science Inventory

    The permeable reactive barrier (PRB) technology represents a passive option for long-term treatment of ground-water contamination. PRBs are a potentially more cost-effective treatment option for a variety of dissolved contaminants, such as certain types of chlorinated solvents, ...

  19. Foam film permeability: theory and experiment.

    PubMed

    Farajzadeh, R; Krastev, R; Zitha, Pacelli L J

    2008-02-28

    The mass transfer of gas through foam films is a prototype of various industrial and biological processes. The aim of this paper is to give a perspective and critical overview of studies carried out to date on the mass transfer of gas through foam films. Contemporary experimental data are summarized, and a comprehensive overview of the theoretical models used to explain the observed effects is given. A detailed description of the processes that occur when a gas molecule passes through each layer that forms a foam film is shown. The permeability of the film-building surfactant monolayers plays an important role for the whole permeability process. It can be successfully described by the models used to explain the permeability of surfactant monolayers on aqueous sub-phase. For this reason, the present paper briefly discusses the surfactant-induced resistance to mass transfer of gases through gas-liquid interface. One part of the paper discusses the experimental and theoretical aspects of the foam film permeability in a train of foam films in a matrix or a cylinder. This special case is important to explain the gas transfer in porous media or in foams. Finally, this paper will highlight the gaps and challenges and sketch possible directions for future research.

  20. SINGLE-INTERVAL GAS PERMEABILITY ESTIMATION

    EPA Science Inventory

    Single-interval, steady-steady-state gas permeability testing requires estimation of pressure at a screened interval which in turn requires measurement of friction factors as a function of mass flow rate. Friction factors can be obtained by injecting air through a length of pipe...

  1. Application peculiarities of magnetic materials for protection from magnetic fields

    NASA Astrophysics Data System (ADS)

    Wai, P.; Dmitrenko, V.; Grabchikov, S.; Vlasik, K.; Novikov, A.; Petrenko, D.; Trukhanov, V.; Ulin, S.; Uteshev, Z.; Chernysheva, V.; Shustov, A.

    2016-02-01

    In different materials for magnetic shields, the maximum permeability is achieved for different values of the magnetic field. This determines the choice of material. So for protection from magnetic fields strength of 10 - 150 A/m it is advisable to apply the amorphous ribbon 84KXCP. For stronger fields (more than 400 A/m) it is recommended to use MFS based on Ni20Fe80. Use of these materials allows creating an effective shield working in a wide range of magnetic field strengths.

  2. Magnetic relaxations in a Tb-based single molecule magnet studied by quasielastic neutron scattering

    NASA Astrophysics Data System (ADS)

    Kofu, Maiko; Kajiwara, Takashi; Gardner, Jason S.; Simeoni, Giovanna G.; Tyagi, Madhusudan; Faraone, Antonio; Nakajima, Kenji; Ohira-Kawamura, Seiko; Nakano, Motohiro; Yamamuro, Osamu

    2013-12-01

    By using ac magnetic susceptibility and quasielatic neutron scattering (QENS) techniques, we have investigated a magnetization relaxation phenomenon of a rare-earth based single molecule magnet, TbCuC19H20N3O16. We clearly identified and characterized two magnetic relaxations. The slower relaxation observed in the ac susceptibility is at the ms timescale around T=2 K and its activation energy is 16 K. On the other hand, the faster relaxation in the QENS measurements occurs on the timescale between ns and ps with activation energy of 174 K. The slower relaxation may occur through thermally activated tunneling among magnetic substates. We discuss two possible origins for the faster relaxation; one is a thermally activated tunneling between the higher excited states, the other is the magnetic relaxation coupled with the motion of ligands around the magnetic ions. This is the first clear observation of magnetic relaxation on the single molecule magnet revealed by QENS.

  3. DNA excision repair in permeable human fibroblasts

    SciTech Connect

    Kaufmann, W.K.; Bodell, W.J.; Cleaver, J.E.

    1983-01-01

    U.v. irradiation of confluent human fibroblasts activated DNA repair, aspects of which were characterized in the cells after they were permeabilized. Incubation of intact cells for 20 min between irradiation and harvesting was necessary to obtain a maximum rate of reparative DNA synthesis. Cells harvested immediately after irradiation before repair was initiated displayed only a small stimulation of DNA synthesis, indicating that permeable cells have a reduced capacity to recognize pyrimidine dimers and activate repair. The distribution of sizes of DNA strands labeled during 10 min of reparative DNA synthesis resembled that of parental DNA. However, during a 60-min incubation of permeable cells at 37 degrees C, parental DNA and DNA labeled by reparative DNA synthesis were both cleaved to smaller sizes. Cleavage also occurred in unirradiated cells, indicating that endogenous nuclease was active during incubation. Repair patches synthesized in permeable cells displayed increased sensitivity to digestion by micrococcal nuclease. However, the change in sensitivity during a chase with unlabeled DNA precursors was small, suggesting that reassembly of nucleosome structure at sites of repair was impaired. To examine whether this deficiency was due to a preponderance of incomplete or unligated repair patches, 3H-labeled (repaired) DNA was purified, then digested with exonuclease III and nuclease S1 to probe for free 3' ends and single-stranded regions. About 85% of the (3H)DNA synthesized during a 10-min pulse resisted digestion, suggesting that a major fraction of the repair patches that were filled were also ligated. U.v. light-activated DNA synthesis in permeable cells, therefore, appears to represent the continuation of reparative gap-filling at sites of excision repair activated within intact cells. Gap-filling and ligation were comparatively efficient processes in permeable cells.

  4. Connexin Channel Permeability to Cytoplasmic Molecules

    PubMed Central

    Harris, Andrew L.

    2007-01-01

    Connexin channels are known to be permeable to a variety of cytoplasmic molecules. The first observation of second messenger junctional permeability, made ∼30 years ago, sparked broad interest in gap junction channels as mediators of intercellular molecular signaling. Since then, much has been learned about the diversity of connexin channels with regard to isoform diversity, tissue and developmental distribution, modes of channel regulation, assembly and expression, biochemical modification and permeability, all of which appear to be dynamically regulated. This information has expanded the potential roles of connexin channels in development, physiology and disease, and made their elucidation much more complex - 30 years ago such an orchestra of junctional dynamics was unanticipated. Only recently, however, have investigators been able to directly address, in this more complex framework, the key issue: What specific biological molecules, second messengers and others, are able to permeate the various types of connexin channels, and how well? An important related issue, given the ever-growing list of connexin-related pathologies, is how these permeabilities are altered by disease-causing connexin mutations. Together, many studies show that a variety of cytoplasmic molecules can permeate the different types of connexin channels. A few studies reveal differences in permeation by different molecules through a particular type of connexin channel, and differences in permeation by a particular molecule through different types of connexin channels. This article describes and evaluates the various methods used to obtain these data, presents an annotated compilation of the results, and discusses the findings in the context of what can be inferred about mechanism of selectivity and potential relevance to signaling. The data strongly suggest that highly specific interactions take place between connexin pores and specific biological molecular permeants, and that those

  5. Permeability during densification of viscous droplets

    NASA Astrophysics Data System (ADS)

    Wadsworth, Fabian; Vasseur, Jérémie; Llewellin, Ed; Dobson, Katherine; Schauroth, Jenny; Heap, Michael; Farquharson, Jamie; Scheu, Bettina; Kendrick, Jackie; Lavallée, Yan; von Aulock, Felix; Dingwell, Donald B.

    2016-04-01

    Fragmentation of magma can yield a transiently granular material, which can subsequently weld back to a fluid-continuum. This process results in dramatic changes in the porosity of the material, which impacts its fluid permeability. We collate published data for the porosity and permeability of volcanic and synthetic materials which have undergone this process to different amounts. By discriminating data for which good microstructural information are provided, we use simple scaling arguments to collapse the data in both the still-granular, high porosity region, and the fluid-continuum low porosity region, such that a universal description can be provided. This allows us to describe the microstructural meaning of permeability scaling, and to infer the controls on the position of this transition between dominantly granular (dispersion) and dominantly fluid-continuum materials. Fractures in coherent magmas are thought to be a primary degassing pathway in high viscosity systems. As a specific application, we consider transiently granular magma being transported through and deposited in these fractures. We finally present a physical model for the kinetics of porosity changes in arrays of viscous droplets and compare this with our experimental data. The combination of the physical model for the evolution of porosity with the scaling between porosity and permeability permits us to describe the evolution of permeability during densification. We anticipate that this will be a useful tool for predicting the longevity of degassing pathways in granular filled cracks, both in conduits and shallow lava domes, as well as during the sedimentation of exceptionally hot ignimbrites undergoing compaction and welding.

  6. Permanent Magnet Ecr Plasma Source With Magnetic Field Optimization

    DOEpatents

    Doughty, Frank C.; Spencer, John E.

    2000-12-19

    In a plasma-producing device, an optimized magnet field for electron cyclotron resonance plasma generation is provided by a shaped pole piece. The shaped pole piece adjusts spacing between the magnet and the resonance zone, creates a convex or concave resonance zone, and decreases stray fields between the resonance zone and the workpiece. For a cylindrical permanent magnet, the pole piece includes a disk adjacent the magnet together with an annular cylindrical sidewall structure axially aligned with the magnet and extending from the base around the permanent magnet. The pole piece directs magnetic field lines into the resonance zone, moving the resonance zone further from the face of the magnet. Additional permanent magnets or magnet arrays may be utilized to control field contours on a local scale. Rather than a permeable material, the sidewall structure may be composed of an annular cylindrical magnetic material having a polarity opposite that of the permanent magnet, creating convex regions in the resonance zone. An annular disk-shaped recurve section at the end of the sidewall structure forms magnetic mirrors keeping the plasma off the pole piece. A recurve section composed of magnetic material having a radial polarity forms convex regions and/or magnetic mirrors within the resonance zone.

  7. ac electroosmosis in rectangular microchannels.

    PubMed

    Campisi, Michele; Accoto, Dino; Dario, Paolo

    2005-11-22

    Motivated by the growing interest in ac electroosmosis as a reliable no moving parts strategy to control fluid motion in microfluidic devices for biomedical applications, such as lab-on-a-chip, we study transient and steady-state electrokinetic phenomena (electroosmosis and streaming currents) in infinitely extended rectangular charged microchannels. With the aid of Fourier series and Laplace transforms we provide a general formal solution of the problem, which is used to study the time-dependent response to sudden ac applied voltage differences in case of finite electric double layer. The Debye-Huckel approximation has been adopted to allow for an algebraic solution of the Poisson-Boltzmann problem in Fourier space. We obtain the expressions of flow velocity profiles, flow rates, streaming currents, as well as expressions of the complex hydraulic and electrokinetic conductances. We analyze in detail the dependence of the electrokinetic conductance on the extension of linear dimensions relative to the Debye length, with an eye on finite electric double layer effects.

  8. ACS PSF Variations with Temperatures

    NASA Astrophysics Data System (ADS)

    Sahu, Kailash C.; Lallo, Matt; Makidon, Russ

    2007-09-01

    We have used the HST ACS/WFC observations of a Galactic bulge field taken over a continuous interval of 7 days (Prop 9750) to investigate the possible dependence of the ACS focus with the external temperatures. This dataset allows us to investigate possible focus variations over timescales of a few hours to a few days. The engineering data related to the external temperatures for this duration show that the maximum temperature change occurred over the first 1.5 days. Among all the different temperatures recorded, the truss diametric differential and the truss axial temperatures are the only two temperatures which have the same timescale of variation as the PSFwidth variations. The PSF-widths also strongly correlate with these two temperatures during this time interval. We empirically fit the PSF-width variations with these 2 temperature sensor values. This suggests that the focus has a similar dependence, and we recommend that this finding be followed up with the determination of actual focus values to check if the focus values indeed have the same correlation. If so, the temperature data can be useful in estimating the focus values, which can then be used to predict the PSFs to a first order.

  9. ac electroosmosis in rectangular microchannels

    NASA Astrophysics Data System (ADS)

    Campisi, Michele; Accoto, Dino; Dario, Paolo

    2005-11-01

    Motivated by the growing interest in ac electroosmosis as a reliable no moving parts strategy to control fluid motion in microfluidic devices for biomedical applications, such as lab-on-a-chip, we study transient and steady-state electrokinetic phenomena (electroosmosis and streaming currents) in infinitely extended rectangular charged microchannels. With the aid of Fourier series and Laplace transforms we provide a general formal solution of the problem, which is used to study the time-dependent response to sudden ac applied voltage differences in case of finite electric double layer. The Debye-Hückel approximation has been adopted to allow for an algebraic solution of the Poisson-Boltzmann problem in Fourier space. We obtain the expressions of flow velocity profiles, flow rates, streaming currents, as well as expressions of the complex hydraulic and electrokinetic conductances. We analyze in detail the dependence of the electrokinetic conductance on the extension of linear dimensions relative to the Debye length, with an eye on finite electric double layer effects.

  10. Optical effective media with independent control of permittivity and permeability based on conductive particles

    NASA Astrophysics Data System (ADS)

    Chung, Kyungjae; Kim, Reehyang; Chang, Taeyong; Shin, Jonghwa

    2016-07-01

    We propose and prove that it is possible to decouple the electric and magnetic response of an array of conductive nanoparticles and realize a very wide range of combinations of effective permittivities and permeabilities. The principle exploits the large differences in the Thomas-Fermi screening length for longitudinal electric fields and the classical penetration depth for time-varying transverse magnetic fields. This non-resonant principle allows frequency invariance of the effective material properties with a bandwidth spanning many octaves, orders of magnitude larger than previous resonant metamaterials. An effective medium with a record-high refractive index over broadband is demonstrated as an example.

  11. A new quasi-steady method to measure gas permeability of weakly permeable porous media

    NASA Astrophysics Data System (ADS)

    Jannot, Yves; Lasseux, Didier

    2012-01-01

    A new quasi-steady method for the determination of the apparent gas permeability of porous materials is presented in this paper along with the corresponding interpretative physical model derived from the unsteady flow equations. This method is mainly dedicated to the measurement of very low permeability of thin porous media, although thicker but more permeable samples may also be analyzed. The method relies on quasi-steady flow resulting from a (quasi) constant pressure maintained at the inlet face of the sample. Gas flow-rate, as low as 3 × 10-10 m3/s, is determined from the record of pressure increase in a reservoir connected to the outlet face of the sample. An estimate of the characteristic time, tc, to reach quasi-steady flow after imposing a constant pressure at the inlet is derived. It is validated by direct numerical simulations of the complete unsteady flow, clearly defining the required experimental duration for the method to apply. Experimental results obtained on rather permeable and thick rock samples are reported showing an excellent agreement of the measured permeability with that determined independently on the same sample whereas the experimental value of tc is also in very good agreement with the predicted one. The method is further employed on a composite material sheet allowing the identification of an apparent gas permeability of about 10-23 m2.

  12. Lunar magnetism. [primordial core model

    NASA Technical Reports Server (NTRS)

    Goldstein, M. L.

    1975-01-01

    It is shown, for a very simple model of the moon, that the existence of a primordial core magnetic field would give rise to a present day nonzero dipole external field. In the investigation a uniformly magnetized core embedded in a permeable mantle is considered. The significance of the obtained results for the conclusions reported by Runcorn (1975) is discussed. Comments provided by Runcorn to the discussion are also presented.

  13. Longitudinal magnetization loss in twisted multifilamentary Bi2223 tape

    NASA Astrophysics Data System (ADS)

    Amemiya, N.; Rabbers, J.-J.; Krooshoop, B. E.; ten Haken, B.; ten Kate, H.; Ayai, N.; Hayashi, K.

    2002-08-01

    Multifilamentary Bi2223 tapes are exposed to the longitudinal magnetic field as well as the transverse one in some electrical power apparatuses such as multilayer power transmission cables. Here, we define the longitudinal and transverse magnetic fields as the field components parallel and perpendicular to the tape axis, respectively. If the filament-bundle is twisted, it can couple to the AC longitudinal magnetic field to generate the longitudinal magnetization loss. Furthermore, the AC transport current flowing spirally in the twisted filament-bundle possibly influences the longitudinal magnetization. The longitudinal magnetization loss was measured in a twisted multifilamentary Bi2223 tape exposed to longitudinal magnetic field and carrying the transport current. The measured longitudinal magnetization loss in the twisted tape exposed to the longitudinal magnetic field is larger than that in another untwisted tape. Supplying the AC transport current changes the longitudinal magnetization loss in the twisted tape exposed to the AC longitudinal magnetic field. The influence of the transport current depends on the phase relation between the longitudinal magnetic field and the transport current. If their phase difference is 0°, the longitudinal magnetization loss decreases remarkably with increasing amplitude of the transport current. It means that the change in the current distribution due to the transport current results in the decrease in the power flow from the magnet power supply. But, a preliminary measurement of the transport loss shows that the total loss increases with increasing transport current.

  14. Moisture Durability of Vapor Permeable Insulating Sheathing (Fact Sheet)

    SciTech Connect

    Not Available

    2013-10-01

    In this project, Building America team Building Science Corporation researched some of the ramifications of using exterior, vapor permeable insulation on retrofit walls with vapor permeable cavity insulation. Retrofit strategies are a key factor in reducing exterior building stock consumption.

  15. In vivo heating of magnetic nanoparticles in alternating magnetic field.

    PubMed

    Babincová, M; Altanerová, V; Altaner, C; Cicmanec, P; Babinec, P

    2004-08-01

    We have evaluated heating capabilities of new magnetic nanoparticles. In in vitro experiments they were exposed to an alternating magnetic field with frequency 3.5 MHz and induction 1.5 mT produced in three turn pancake coil. In in vivo experiments rats with injected magnetic nanoparticles were also exposed to an ac field. An optimal increase of temperature of the tumor to 44 degrees C was achieved after 10 minutes of exposure. Obtained results showed that magnetic nanoparticles may be easily heated in vitro as well as in vivo, and may be therefore useful for hyperthermic therapy of cancer.

  16. Exploring the scale-dependent permeability of fractured andesite

    NASA Astrophysics Data System (ADS)

    Heap, Michael J.; Kennedy, Ben M.

    2016-08-01

    Extension fractures in volcanic systems exist on all scales, from microscopic fractures to large fissures. They play a fundamental role in the movement of fluids and distribution of pore pressure, and therefore exert considerable influence over volcanic eruption recurrence. We present here laboratory permeability measurements for porous (porosity = 0.03-0.6) andesites before (i.e., intact) and after failure in tension (i.e., the samples host a throughgoing tensile fracture). The permeability of the intact andesites increases with increasing porosity, from 2 ×10-17 to 5 ×10-11 m2. Following fracture formation, the permeability of the samples (the equivalent permeability) falls within a narrow range, 2- 6 ×10-11 m2, regardless of their initial porosity. However, laboratory measurements on fractured samples likely overestimate the equivalent permeability due to the inherent scale-dependence of permeability. To explore this scale-dependence, we first determined the permeability of the tensile fractures using a two-dimensional model that considers flow in parallel layers. Our calculations highlight that tensile fractures in low-porosity samples are more permeable (as high as 3.5 ×10-9 m2) than those in high-porosity samples (as low as 4.1 ×10-10 m2), a difference that can be explained by an increase in fracture tortuosity with porosity. We then use our fracture permeability data to model the equivalent permeability of fractured rock (with different host rock permeabilities, from 10-17 to 10-11 m2) with increasing lengthscale. We highlight that our modelling approach can be used to estimate the equivalent permeability of numerous scenarios at andesitic stratovolcanoes in which the fracture density and width and host rock porosity or permeability are known. The model shows that the equivalent permeability of fractured andesite depends heavily on the initial host rock permeability and the scale of interest. At a given lengthscale, the equivalent permeability of

  17. Scanning electron microscopy and dentinal permeability analysis of smear layer.

    PubMed

    Prati, C; Mongiorgi, R; Pashley, D H; Riva di Sanseverino, L

    1991-05-01

    The aim of the present study was to evaluate the surface morphology and the permeability of dentine after different acid treatments: polyacrylic acid, maleic acid, phosphoric acid and saline solution as control. Dentine permeability was expressed as hydraulic conductance. All the acid treatments removed the smear layer and increased the dentine permeability.

  18. 46 CFR 174.090 - Permeability of spaces.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Permeability of spaces. 174.090 Section 174.090 Shipping... Permeability of spaces. When doing the calculations required in § 174.065— (a) The permeability of a floodable space, other than a machinery space, must be as listed in Table 174.090; and (b) Calculations in which...

  19. 46 CFR 172.240 - Permeability of spaces.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Permeability of spaces. 172.240 Section 172.240 Shipping... Permeability of spaces. When doing the calculations required in § 172.225, (a) The permeability of a floodable space, other than a machinery or cargo space, must be assumed as listed in Table 172.240;...

  20. 46 CFR 172.185 - Permeability of spaces.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Permeability of spaces. 172.185 Section 172.185 Shipping... Under Subchapter O of This Chapter § 172.185 Permeability of spaces. (a) When doing the calculations required in § 172.170, the permeability of a floodable space other than a machinery space must be as...

  1. 46 CFR 172.185 - Permeability of spaces.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Permeability of spaces. 172.185 Section 172.185 Shipping... Under Subchapter O of This Chapter § 172.185 Permeability of spaces. (a) When doing the calculations required in § 172.170, the permeability of a floodable space other than a machinery space must be as...

  2. 46 CFR 172.140 - Permeability of spaces.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Permeability of spaces. 172.140 Section 172.140 Shipping... Subchapter O of This Chapter § 172.140 Permeability of spaces. (a) When doing the calculations required in § 172.130, the permeability of a floodable space other than a machinery space must be as listed in...

  3. 46 CFR 172.240 - Permeability of spaces.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Permeability of spaces. 172.240 Section 172.240 Shipping... Permeability of spaces. When doing the calculations required in § 172.225, (a) The permeability of a floodable space, other than a machinery or cargo space, must be assumed as listed in Table 172.240;...

  4. 46 CFR 174.090 - Permeability of spaces.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Permeability of spaces. 174.090 Section 174.090 Shipping... Permeability of spaces. When doing the calculations required in § 174.065— (a) The permeability of a floodable space, other than a machinery space, must be as listed in Table 174.090; and (b) Calculations in which...

  5. 46 CFR 172.185 - Permeability of spaces.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Permeability of spaces. 172.185 Section 172.185 Shipping... Under Subchapter O of This Chapter § 172.185 Permeability of spaces. (a) When doing the calculations required in § 172.170, the permeability of a floodable space other than a machinery space must be as...

  6. 46 CFR 174.090 - Permeability of spaces.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Permeability of spaces. 174.090 Section 174.090 Shipping... Permeability of spaces. When doing the calculations required in § 174.065— (a) The permeability of a floodable space, other than a machinery space, must be as listed in Table 174.090; and (b) Calculations in which...

  7. 46 CFR 172.140 - Permeability of spaces.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Permeability of spaces. 172.140 Section 172.140 Shipping... Subchapter O of This Chapter § 172.140 Permeability of spaces. (a) When doing the calculations required in § 172.130, the permeability of a floodable space other than a machinery space must be as listed in...

  8. 46 CFR 172.140 - Permeability of spaces.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Permeability of spaces. 172.140 Section 172.140 Shipping... Subchapter O of This Chapter § 172.140 Permeability of spaces. (a) When doing the calculations required in § 172.130, the permeability of a floodable space other than a machinery space must be as listed in...

  9. 46 CFR 172.240 - Permeability of spaces.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Permeability of spaces. 172.240 Section 172.240 Shipping... Permeability of spaces. When doing the calculations required in § 172.225, (a) The permeability of a floodable space, other than a machinery or cargo space, must be assumed as listed in Table 172.240;...

  10. 21 CFR 886.5916 - Rigid gas permeable contact lens.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Rigid gas permeable contact lens. 886.5916 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5916 Rigid gas permeable contact lens. (a) Identification. A rigid gas permeable contact lens is a device intended to be worn...

  11. 21 CFR 886.5916 - Rigid gas permeable contact lens.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Rigid gas permeable contact lens. 886.5916 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5916 Rigid gas permeable contact lens. (a) Identification. A rigid gas permeable contact lens is a device intended to be worn...

  12. 21 CFR 886.5916 - Rigid gas permeable contact lens.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid gas permeable contact lens. 886.5916 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5916 Rigid gas permeable contact lens. (a) Identification. A rigid gas permeable contact lens is a device intended to be worn...

  13. 21 CFR 886.5916 - Rigid gas permeable contact lens.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Rigid gas permeable contact lens. 886.5916 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5916 Rigid gas permeable contact lens. (a) Identification. A rigid gas permeable contact lens is a device intended to be worn...

  14. 21 CFR 886.5916 - Rigid gas permeable contact lens.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Rigid gas permeable contact lens. 886.5916 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5916 Rigid gas permeable contact lens. (a) Identification. A rigid gas permeable contact lens is a device intended to be worn...

  15. Studying the Variation in Gas Permeability of Porous Building Substrates

    NASA Astrophysics Data System (ADS)

    Townsend, L.; Savidge, C. R.; Hu, L.; Rizzo, D. M.; Hayden, N. J.; Dewoolkar, M.

    2009-12-01

    Understanding permeability of building materials is important for problems involving studies of contaminant transport. Examples include contamination from fire, acid rain, and chemical and biological weapons. Our research investigates the gas permeability of porous building substrates such as concretes, limestones, sandstones, and bricks. Each sample was cored to produce 70 mm (2.75”) diameter cores approximately 75-130 mm (3-5”) tall. The surface gas permeability was measured on the top surface of these specimens using the AutoScan II device manufactured by New England Research, Inc. The measurements were taken along a 3 mm grid producing a map of surface gas permeability. An example map is shown in Figure 1. The macroscopic measurements were performed along the entire cored specimen. A second set of measurements were made on a 5 mm thick slice cut from the top of each specimen to examine whether these measurements compare better with the surface measurements. The macroscopic gas permeability was measured for all specimens using ASTM D 4525. The results are summarized in Table 1. In general, the surface and macroscopic gas permeability measurements (Table 1) compare reasonably well (within one order of magnitude). The permeability of the 5 mm slices is not significantly different from the entire core for the specimens tested. Figure 1. Results of surface permeability mappingof Ohio Sandstone using the AutoScan II device. a) Map of gas permeability b) Range of gas permeability c) Density function of permeability. Table 1. Gas permeability values (mD)

  16. 46 CFR 172.185 - Permeability of spaces.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Permeability of spaces. 172.185 Section 172.185 Shipping... Under Subchapter O of This Chapter § 172.185 Permeability of spaces. (a) When doing the calculations required in § 172.170, the permeability of a floodable space other than a machinery space must be as...

  17. 46 CFR 174.090 - Permeability of spaces.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Permeability of spaces. 174.090 Section 174.090 Shipping... Permeability of spaces. When doing the calculations required in § 174.065— (a) The permeability of a floodable space, other than a machinery space, must be as listed in Table 174.090; and (b) Calculations in which...

  18. 46 CFR 172.240 - Permeability of spaces.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Permeability of spaces. 172.240 Section 172.240 Shipping... Permeability of spaces. When doing the calculations required in § 172.225, (a) The permeability of a floodable space, other than a machinery or cargo space, must be assumed as listed in Table 172.240;...

  19. 46 CFR 172.140 - Permeability of spaces.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Permeability of spaces. 172.140 Section 172.140 Shipping... Subchapter O of This Chapter § 172.140 Permeability of spaces. (a) When doing the calculations required in § 172.130, the permeability of a floodable space other than a machinery space must be as listed in...

  20. 46 CFR 172.240 - Permeability of spaces.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Permeability of spaces. 172.240 Section 172.240 Shipping... Permeability of spaces. When doing the calculations required in § 172.225, (a) The permeability of a floodable space, other than a machinery or cargo space, must be assumed as listed in Table 172.240;...