Science.gov

Sample records for ac power line

  1. Coupling an induction motor type generator to ac power lines. [making windmill generators compatible with public power lines

    NASA Technical Reports Server (NTRS)

    Nola, F. J. (Inventor)

    1984-01-01

    A system for coupling an induction motor type generator to an A.C. power line includes an electronic switch means that is controlled by a control system and is regulated to turn on at a relatively late point in each half cycle of its operation. The energizing power supplied by the line to the induction motor type generator is decreased and the net power delivered to the line is increased.

  2. A system for tranmitting low frequency analog signals over ac power lines

    DOEpatents

    Baker, S.P.; Durall, R.L.; Haynes, H.D.

    1987-07-30

    A system for transmitting low frequency analog signals over ac power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an ac power line. The modulation signal frequency range is selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the ac power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal. 4 figs.

  3. System for transmitting low frequency analog signals over AC power lines

    DOEpatents

    Baker, Steven P.; Durall, Robert L.; Haynes, Howard D.

    1989-09-05

    A system for transmitting low frequency analog signals over AC power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an AC power line. The modulation signal frequency range in selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the AC power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal.

  4. System for transmitting low frequency analog signals over AC power lines

    DOEpatents

    Baker, Steven P.; Durall, Robert L.; Haynes, Howard D.

    1989-01-01

    A system for transmitting low frequency analog signals over AC power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an AC power line. The modulation signal frequency range in selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the AC power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal.

  5. Increased deposition of polychlorinated biphenyls (PCBs) under an AC high-voltage power line

    NASA Astrophysics Data System (ADS)

    Öberg, Tomas; Peltola, Pasi

    2009-12-01

    There is considerable public concern regarding the potential risks to health of electromagnetic fields in general and high-voltage power lines in particular. As epidemiological findings are not supported by a clearly defined mechanism of direct magnetic field interactions with the human body, potential indirect effects are of interest. It has been suggested that an increased exposure to chemical pollutants could occur near high-voltage power lines due to formation and deposition of charged aerosols. The current study reports empirical evidence that seems to support this hypothesis. The deposition of 18 congeners of polychlorinated biphenyls (PCBs) was studied by collecting samples of pine needles under a 400 kV AC power line and at reference sites in the vicinity. Compared to the reference sites, the average deposition of PCB congeners under the power line was almost double. This difference between the two groups of samples was statistically significant. While it is premature to draw any conclusions regarding the human exposure near high-voltage power lines, the issue deserves attention and further investigations.

  6. Statistical evaluation of telephone noise interference caused by AC power line harmonic currents

    SciTech Connect

    Kuussaari, M. )

    1993-04-01

    A statistical approach is applied for the evaluation of the limits for harmonic currents in AC power lines, the goal being to prevent excessive telephone noise interference voltages in subscriber cables in rural areas. The analysis is based on Monte-Carlo simulation which takes into account the effect of the experiental probability distributions of the relevant parameters. In the Finnish conditions, the properties of communication cables permit equivalent disturbing phase currents of 8 to 10 A. The digital exchanges permit approximately the same currents. Some new telephone types that have a low balance may make it necessary to limit the currents to a level that is somewhat lower.

  7. Single and three-phase AC losses in HTS superconducting power transmission line prototype cables

    SciTech Connect

    Daney, D.E.; Boenig, H.J.; Maley, M.P.; Coulter, J.Y.; Fleshler, S.

    1997-11-01

    AC losses in two, one-meter-long lengths of HTS prototype multi-strand conductors (PMC`s) are measured with a temperature-difference calorimeter. Both single-phase and three-phase losses are examined with ac currents up to 1,000 A rms. The calorimeter, designed specifically for these measurements, has a precision of 1 mW. PMC {number_sign}1 has two helically-wound, non-insulated layers of HTS tape (19 tapes per layer), each layer wrapped with opposite pitch. PMC {number_sign}2 is identical except for insulation between the layers. The measured ac losses show no significant effect of interlayer insulation and depend on about the third power of the current--a result in agreement with the Bean-Norris model adapted to the double-helix configuration. The three-phase losses are a factor of two higher than those exhibited by a single isolated conductor, indicating a significant interaction between phases.

  8. AC power systems handbook

    SciTech Connect

    Whitaker, J.

    1991-01-01

    Transient disturbances are what headaches are made of. Whatever you call them-spikes, surges, are power bumps-they can take your equipment down and leave you with a complicated and expensive repair job. Protection against transient disturbances is a science that demands attention to detail. This book explains how the power distribution system works, what can go wrong with it, and how to protect a facility against abnormalities. system grounding and shielding are covered in detail. Each major method of transient protection is analyzed and its relative merits discussed. The book provides a complete look at the critical elements of the ac power system. Provides a complete look at the ac power system from generation to consumption. Discusses the mechanisms that produce transient disturbances and how to protect against them. Presents diagrams to facilitate system design. Covers new areas, such as the extent of the transient disturbance problem, transient protection options, and stand-by power systems.

  9. Uncertainty evaluation in the measurement of power frequency electric and magnetic fields from AC overhead power lines.

    PubMed

    Ztoupis, I N; Gonos, I F; Stathopulos, I A

    2013-11-01

    Measurements of power frequency electric and magnetic fields from alternating current power lines are carried out in order to evaluate the exposure levels of the human body on the general public. For any electromagnetic field measurement, it is necessary to define the sources of measurement uncertainty and determine the total measurement uncertainty. This paper is concerned with the problems of measurement uncertainty estimation, as the measurement uncertainty budget calculation techniques recommended in standardising documents and research studies are barely described. In this work the total uncertainty of power frequency field measurements near power lines in various measurement sites is assessed by considering not only all available equipment data, but also contributions that depend on the measurement procedures, environmental conditions and characteristics of the field source, which are considered to increase the error of measurement. A detailed application example for power frequency field measurements is presented here by accredited laboratory.

  10. Semiconductor ac static power switch

    NASA Technical Reports Server (NTRS)

    Vrancik, J.

    1968-01-01

    Semiconductor ac static power switch has long life and high reliability, contains no moving parts, and operates satisfactorily in severe environments, including high vibration and shock conditions. Due to their resistance to shock and vibration, static switches are used where accidental switching caused by mechanical vibration or shock cannot be tolerated.

  11. Simultaneous distribution of AC and DC power

    DOEpatents

    Polese, Luigi Gentile

    2015-09-15

    A system and method for the transport and distribution of both AC (alternating current) power and DC (direct current) power over wiring infrastructure normally used for distributing AC power only, for example, residential and/or commercial buildings' electrical wires is disclosed and taught. The system and method permits the combining of AC and DC power sources and the simultaneous distribution of the resulting power over the same wiring. At the utilization site a complementary device permits the separation of the DC power from the AC power and their reconstruction, for use in conventional AC-only and DC-only devices.

  12. Composite rod insulators for ac power lines; Electrical performance of various designs at a coastal testing station

    SciTech Connect

    Houlgate, R.G.; Swift, D.A. )

    1990-10-01

    The electrical performance of thirty-six composite insulators - of four commercial types for each AC system level of 34.5 kV, 230 kV and 500 kV - has been determined at the CEGB insulator testing station, Brighton, England. The weathershed materials were epoxy-resin, ethylene propylene rubber and silicone rubber; half of the 230 kV insulators had no stress rings. Surface leakage current was recorded for surge levels of 25 mA, 150 mA and 500 mA; a special technique was developed to obtain the flashover statistics of the 500 kV insulators, thereby enabling performance of the composite insulator to be quantified relative to that of a string of cap and pin porcelain insulators of anti-fog design, the deterioration of the insulators was observed by making regular visual inspections. The practical consequences of the findings and the causes of the degradation are discussed.

  13. Power factor control system for AC induction motors

    NASA Technical Reports Server (NTRS)

    Nola, F. J. (Inventor)

    1977-01-01

    A power factor control system for use with ac induction motors was designed which samples lines voltage and current through the motor and decreases power input to the motor proportional to the detected phase displacement between current and voltage. This system provides, less power to the motor, as it is less loaded.

  14. AC and DC power transmission

    SciTech Connect

    Not Available

    1985-01-01

    The technical and economic assessment of AC and DC transmission systems; long distance transmission, cable transmission, system inter-connection, voltage support, reactive compensation, stabilisation of systems; parallel operation of DC links with AC systems; comparison between alternatives for particular schemes. Design and application equipment: design, testing and application of equipment for HVDC, series and shunt static compensated AC schemes, including associated controls. Installations: overall design of stations and conductor arrangements for HVDC, series and shunt static AC schemes including insulation co-ordination. System analysis and modelling.

  15. Operation Method for AC Motor Control during Power Interruption in Direct AC/AC Converter System

    NASA Astrophysics Data System (ADS)

    Shizu, Keiichiro; Azuma, Satoshi

    Direct AC/AC converters have been studied due to their potential use in power converters with no DC-link capacitor, which can contribute to the miniaturization of power converters. However, the absence of a DC-link capacitor makes it difficult to control the AC motor during power interruption. First, this paper proposes a system that realizes AC motor control during power interruption by utilizing a clamp capacitor. In general, direct AC/AC converters have a clamp circuit consisting of a rectifier diode(s) and a clamp capacitor in order to avoid over-voltages. In the proposed system, there is an additional semiconductor switch reverse-parallel to the rectifier diode(s), and the clamp capacitor voltage can be utilized for AC motor control by turning on the additional switch. Second, this paper discusses an operation method for AC motor control and clamp capacitor voltage control during power interruption. In the proposed method “DC-link voltage control”, the kinetic energy in the AC motor is transformed into electrical energy and stored in the clamp capacitor; the clamp capacitor is therefore charged and the capacitor voltage is controlled to remain constant at an instruction value. Third, this paper discusses a switching operation during power interruption. A dead-time is introduced between the operation of turning off all switches on the rectifier side and the operation of turning on the additional switch, which prevents the occurrence of a short circuit between the interrupted power source and the clamp capacitor. Finally, experimental results are presented. During power interruptions, an output current was continuously obtained and the clamp capacitor voltage was maintained to be equal to the instruction value of the capacitor voltage. These results indicate that both AC motor control and capacitor voltage control were successfully achieved by using the proposed system.

  16. 21 CFR 888.1240 - AC-powered dynamometer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240...) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a) Identification. An AC-powered dynamometer is an AC-powered device intended for medical purposes to...

  17. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  18. 21 CFR 886.1630 - AC-powered photostimulator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered photostimulator. 886.1630 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1630 AC-powered photostimulator. (a) Identification. An AC-powered photostimulator is an AC-powered device intended to provide light stimulus...

  19. 21 CFR 886.1850 - AC-powered slitlamp biomicroscope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered slitlamp biomicroscope. 886.1850... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1850 AC-powered slitlamp biomicroscope. (a) Identification. An AC-powered slitlamp biomicroscope is an AC-powered device that is...

  20. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  1. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  2. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  3. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  4. Power control for ac motor

    NASA Technical Reports Server (NTRS)

    Dabney, R. W. (Inventor)

    1984-01-01

    A motor controller employing a triac through which power is supplied to a motor is described. The open circuit voltage appearing across the triac controls the operation of a timing circuit. This timing circuit triggers on the triac at a time following turn off which varies inversely as a function of the amplitude of the open circuit voltage of the triac.

  5. dc-to-ac power converter for fuel cell system

    SciTech Connect

    Kawabata, T.; Asaeda, T.; Hamasaki, Y.; Yutani, T.

    1983-10-01

    As the interface between fuel cells and the utility line, a self-commutated inverter is preferred to a line-commutated inverter because of its easy controllability. Using the gate turn off (GTO) thyristors, this inverter can have high efficiency and simple circuit configurations. This paper describes the design features and test results of the dc-to-ac power converter, which is principally composed of four-phase transistor chopper and 12-pulse GTO inverter, for a 50kW experimental fuel cell power system. Furthermore, new GTO inverter which improves the circuit efficiency is presented. Special emphasis is placed on a detailed analysis and evaluation of this GTO inverter.

  6. 21 CFR 880.5500 - AC-powered patient lift.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false AC-powered patient lift. 880.5500 Section 880.5500... Devices § 880.5500 AC-powered patient lift. (a) Identification. An AC-powered lift is an electrically powered device either fixed or mobile, used to lift and transport patients in the horizontal or...

  7. 21 CFR 880.5500 - AC-powered patient lift.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false AC-powered patient lift. 880.5500 Section 880.5500... Devices § 880.5500 AC-powered patient lift. (a) Identification. An AC-powered lift is an electrically powered device either fixed or mobile, used to lift and transport patients in the horizontal or...

  8. 21 CFR 880.5500 - AC-powered patient lift.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false AC-powered patient lift. 880.5500 Section 880.5500... Devices § 880.5500 AC-powered patient lift. (a) Identification. An AC-powered lift is an electrically powered device either fixed or mobile, used to lift and transport patients in the horizontal or...

  9. 21 CFR 880.5500 - AC-powered patient lift.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false AC-powered patient lift. 880.5500 Section 880.5500... Devices § 880.5500 AC-powered patient lift. (a) Identification. An AC-powered lift is an electrically powered device either fixed or mobile, used to lift and transport patients in the horizontal or...

  10. AC power generation from microbial fuel cells

    NASA Astrophysics Data System (ADS)

    Lobo, Fernanda Leite; Wang, Heming; Forrestal, Casey; Ren, Zhiyong Jason

    2015-11-01

    Microbial fuel cells (MFCs) directly convert biodegradable substrates to electricity and carry good potential for energy-positive wastewater treatment. However, the low and direct current (DC) output from MFC is not usable for general electronics except small sensors, yet commercial DC-AC converters or inverters used in solar systems cannot be directly applied to MFCs. This study presents a new DC-AC converter system for MFCs that can generate alternating voltage in any desired frequency. Results show that AC power can be easily achieved in three different frequencies tested (1, 10, 60 Hz), and no energy storage layer such as capacitors was needed. The DC-AC converter efficiency was higher than 95% when powered by either individual MFCs or simple MFC stacks. Total harmonic distortion (THD) was used to investigate the quality of the energy, and it showed that the energy could be directly usable for linear electronic loads. This study shows that through electrical conversion MFCs can be potentially used in household electronics for decentralized off-grid communities.

  11. Reliability of emergency ac power systems at nuclear power plants

    SciTech Connect

    Battle, R E; Campbell, D J

    1983-07-01

    Reliability of emergency onsite ac power systems at nuclear power plants has been questioned within the Nuclear Regulatory Commission (NRC) because of the number of diesel generator failures reported by nuclear plant licensees and the reactor core damage that could result from diesel failure during an emergency. This report contains the results of a reliability analysis of the onsite ac power system, and it uses the results of a separate analysis of offsite power systems to calculate the expected frequency of station blackout. Included is a design and operating experience review. Eighteen plants representative of typical onsite ac power systems and ten generic designs were selected to be modeled by fault trees. Operating experience data were collected from the NRC files and from nuclear plant licensee responses to a questionnaire sent out for this project.

  12. 21 CFR 886.1630 - AC-powered photostimulator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Identification. An AC-powered photostimulator is an AC-powered device intended to provide light stimulus which allows measurement of retinal or visual function by perceptual or electrical methods (e.g.,...

  13. Power line detection system

    DOEpatents

    Latorre, Victor R.; Watwood, Donald B.

    1994-01-01

    A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard.

  14. Power line detection system

    DOEpatents

    Latorre, V.R.; Watwood, D.B.

    1994-09-27

    A short-range, radio frequency (RF) transmitting-receiving system that provides both visual and audio warnings to the pilot of a helicopter or light aircraft of an up-coming power transmission line complex. Small, milliwatt-level narrowband transmitters, powered by the transmission line itself, are installed on top of selected transmission line support towers or within existing warning balls, and provide a continuous RF signal to approaching aircraft. The on-board receiver can be either a separate unit or a portion of the existing avionics, and can also share an existing antenna with another airborne system. Upon receipt of a warning signal, the receiver will trigger a visual and an audio alarm to alert the pilot to the potential power line hazard. 4 figs.

  15. Ac irreversibility line of bismuth-based high temperature superconductors

    SciTech Connect

    Mehdaoui, A.; Beille, J.; Berling, D.; Loegel, B.; Noudem, J.G.; Tournier, R.

    1997-09-01

    We discuss the magnetic properties of lead doped Bi-2223 bulk samples obtained through combined magnetic melt texturing and hot pressing (MMTHP). The ac complex susceptibility measurements are achieved over a broad ac field range (1 Oe{lt}h{sub ac}{lt}100 Oe) and show highly anisotropic properties. The intergranular coupling is improved in the direction perpendicular to the applied stress and magnetic field direction, and an intragranular loss peak is observed for the first time. A comparison is made with other bismuth-based compounds and it is shown that the MMTHP process shifts the ac irreversibility line (ac IL) toward higher fields. It is also shown that all the ac IL{close_quote}s for quasi 2D bismuth-based compounds show a nearly quadratic temperature dependence and deviate therefore strongly from the linear behavior observed in quasi 3D compounds and expected from a critical state model.{copyright} {ital 1997 Materials Research Society.}

  16. 21 CFR 880.5500 - AC-powered patient lift.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered patient lift. 880.5500 Section 880.5500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5500 AC-powered patient lift. (a) Identification. An AC-powered lift is an...

  17. Wind-powered asynchronous AC/DC/AC converter system. [for electric power supply regulation

    NASA Technical Reports Server (NTRS)

    Reitan, D. K.

    1973-01-01

    Two asynchronous ac/dc/ac systems are modelled that utilize wind power to drive a variable or constant hertz alternator. The first system employs a high power 60-hertz inverter tie to the large backup supply of the power company to either supplement them from wind energy, storage, or from a combination of both at a preset desired current; rectifier and inverter are identical and operate in either mode depending on the silicon control rectifier firing angle. The second system employs the same rectification but from a 60-hertz alternator arrangement; it provides mainly dc output, some sinusoidal 60-hertz from the wind bus and some high harmonic content 60-hertz from an 800-watt inverter.

  18. Programmable AC power supply for simulating power transient expected in fusion reactor

    SciTech Connect

    Halimi, B.; Suh, K. Y.

    2012-07-01

    This paper focus on control engineering of the programmable AC power source which has capability to simulate power transient expected in fusion reactor. To generate the programmable power source, AC-AC power electronics converter is adopted to control the power of a set of heaters to represent the transient phenomena of heat exchangers or heat sources of a fusion reactor. The International Thermonuclear Experimental Reactor (ITER) plasma operation scenario is used as the basic reference for producing this transient power source. (authors)

  19. High-Frequency ac Power-Distribution System

    NASA Technical Reports Server (NTRS)

    Hansen, Irving G.; Mildice, James

    1987-01-01

    Loads managed automatically under cycle-by-cycle control. 440-V rms, 20-kHz ac power system developed. System flexible, versatile, and "transparent" to user equipment, while maintaining high efficiency and low weight. Electrical source, from dc to 2,200-Hz ac converted to 440-V rms, 20-kHz, single-phase ac. Power distributed through low-inductance cables. Output power either dc or variable ac. Energy transferred per cycle reduced by factor of 50. Number of parts reduced by factor of about 5 and power loss reduced by two-thirds. Factors result in increased reliability and reduced costs. Used in any power-distribution system requiring high efficiency, high reliability, low weight, and flexibility to handle variety of sources and loads.

  20. Power lines and the geomagnetic field

    SciTech Connect

    Liboff, A.R.; McLeod, B.R.

    1995-09-01

    The metric of prime interest in power line epidemiological studies has been AC magnetic intensity. To consider also possible geomagnetic involvement, the orientation of a long straight power line is examined relative to a uniform geomagnetic field (GMF) with dip angle {alpha}. An expression is derived for the component of the total GMF that is parallel, at an elevation {beta}, to the circular magnetic field that surrounds the line. This component is a function of the angles {alpha} and {beta}, the total geomagnetic intensity B{sub T}, and the angle {theta} between the axis of the power line and magnetic north. Plotting these geomagnetic parameters for known leukemia residences allows one to test for possible ion cyclotron resonance or other GMF interactions. This approach, in principle, is an easy addition to existing or planned studies, because residential access is not required to obtain local values for {alpha}, {beta}, {theta}, and B{sub T}. The authors recommend including these parameters in the design of epidemiological studies examining power line fields and childhood leukemia.

  1. 21 CFR 880.6320 - AC-powered medical examination light.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered medical examination light. 880.6320... Miscellaneous Devices § 880.6320 AC-powered medical examination light. (a) Identification. An AC-powered medical examination light is an AC-powered device intended for medical purposes that is used to illuminate...

  2. High-power ac/dc variable load simulator

    NASA Technical Reports Server (NTRS)

    Joncas, K. P.; Birnbach, S.; Bruce, L. D.; Smith, L.

    1975-01-01

    Design of medium-power dynamic electrical load simulator has been extended to permit simulation of ac as well as dc loads and to provide for operation at higher power levels. Simulator is internally protected against reverse voltage, overvoltage, overcurrent, and overload conditions.

  3. Citizens protest high power lines

    SciTech Connect

    Ray, J.

    1980-04-01

    Survey report:Following an extensive public hearing in New York State concerning the health effects and safety of high voltage power lines, negotiations to establish a research program on the biological effects of the power lines' 60 Hz electric and magnetic fields have been concluded. The aim will be to determine the potential health risks to people who live and work along high voltage rights-of-way. The $5,000,000 program will be designed and administered by three New York State agencies: the Public Service Commission, the Dept. of Health, and the Power Authority. (3 photos)

  4. Introducing AC inductive reactance with a power tool

    NASA Astrophysics Data System (ADS)

    Bryant, Wesley; Baker, Blane

    2016-09-01

    The concept of reactance in AC electrical circuits is often non-intuitive and difficult for students to grasp. In order to address this lack of conceptual understanding, classroom exercises compare the predicted resistance of a power tool, based on electrical specifications, to measured resistance. Once students discover that measured resistance is smaller than expected, they are asked to explain these observations using previously studied principles of magnetic induction. Exercises also introduce the notion of inductive reactance and impedance in AC circuits and, ultimately, determine self-inductance of the motor windings within the power tool.

  5. Resistojet control and power for high frequency ac buses

    NASA Technical Reports Server (NTRS)

    Gruber, Robert P.

    1987-01-01

    Resistojets are operational on many geosynchronous communication satellites which all use dc power buses. Multipropellant resistojets were selected for the Initial Operating Capability (IOC) Space Station which will supply 208 V, 20 kHz power. This paper discusses resistojet heater temperature controllers and passive power regulation methods for ac power systems. A simple passive power regulation method suitable for use with regulated sinusoidal or square wave power was designed and tested using the Space Station multipropellant resistojet. The breadboard delivered 20 kHz power to the resistojet heater. Cold start surge current limiting, a power efficiency of 95 percent, and power regulation of better than 2 percent were demonstrated with a two component, 500 W breadboard power controller having a mass of 0.6 kg.

  6. Introducing AC Inductive Reactance with a Power Tool

    ERIC Educational Resources Information Center

    Bryant, Wesley; Baker, Blane

    2016-01-01

    The concept of reactance in AC electrical circuits is often non-intuitive and difficult for students to grasp. In order to address this lack of conceptual understanding, classroom exercises compare the predicted resistance of a power tool, based on electrical specifications, to measured resistance. Once students discover that measured resistance…

  7. ac power control in the Core Flow Test Loop

    SciTech Connect

    McDonald, D.W.

    1980-01-01

    This work represents a status report on a development effort to design an ac power controller for the Core Flow Test Loop. The Core Flow Test Loop will be an engineering test facility which will simulate the thermal environment of a gas-cooled fast-breeder reactor. The problems and limitations of using sinusoidal ac power to simulate the power generated within a nuclear reactor are addressed. The transformer-thyristor configuration chosen for the Core Flow Test Loop power supply is presented. The initial considerations, design, and analysis of a closed-loop controller prototype are detailed. The design is then analyzed for improved performance possibilities and failure modes are investigated at length. A summary of the work completed to date and a proposed outline for continued development completes the report.

  8. 21 CFR 880.5510 - Non-AC-powered patient lift.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Non-AC-powered patient lift. 880.5510 Section 880... Devices § 880.5510 Non-AC-powered patient lift. (a) Identification. A non-AC-powered patient lift is a hydraulic, battery, or mechanically powered device, either fixed or mobile, used to lift and transport...

  9. 21 CFR 880.5510 - Non-AC-powered patient lift.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Non-AC-powered patient lift. 880.5510 Section 880... Devices § 880.5510 Non-AC-powered patient lift. (a) Identification. A non-AC-powered patient lift is a hydraulic, battery, or mechanically powered device, either fixed or mobile, used to lift and transport...

  10. 21 CFR 880.5510 - Non-AC-powered patient lift.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Non-AC-powered patient lift. 880.5510 Section 880... Devices § 880.5510 Non-AC-powered patient lift. (a) Identification. A non-AC-powered patient lift is a hydraulic, battery, or mechanically powered device, either fixed or mobile, used to lift and transport...

  11. 21 CFR 880.5510 - Non-AC-powered patient lift.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Non-AC-powered patient lift. 880.5510 Section 880... Devices § 880.5510 Non-AC-powered patient lift. (a) Identification. A non-AC-powered patient lift is a hydraulic, battery, or mechanically powered device, either fixed or mobile, used to lift and transport...

  12. UPS with input commutation between ac and dc sources of power

    SciTech Connect

    Severinsky, A.J.

    1993-08-31

    An uninterruptible power supply is described, said power supply comprising: AC input terminal means for receiving a first AC voltage from an AC power source; DC input terminal means for receiving a first DC voltage from a DC power source; AC output terminal means for connecting to a load; converter means for converting said first AC voltage to a second DC voltage across electrical charge storage means coupled to said converter means, said second DC voltage being larger than the maximum peak voltage of said first AC voltage and said first DC voltage; switching means coupled to said AC power source and said DC power source for selectively connecting said AC power source or said DC power source to said converter means; inverter means coupled to said electrical charge storage means for receiving said second DC voltage and inverting said second DC voltage to a second AC voltage, said second AC voltage being coupled to said AC output terminal means; and control means coupled to said switching means for controlling the operation of said switching means, said control means operating said switching means to connect said AC power source to said converter means only when said first AC voltage is within a predetermined range and operating to connect said DC power source to said converter means when said first AC voltage is outside of said range.

  13. AC and lightning performance of fiberglass crossarms aged in 115 kV transmission line

    SciTech Connect

    Grzybowski, S. . Dept. of Electrical and Computer Engineering); Jenkins, E.B. . Generation and Transmission Group)

    1993-10-01

    This paper presents the results of an investigation of the electrical performance of 115 kV transmission line fiberglass cross-arm used by Mississippi Power and Light Company. A transmission line fiberglass crossarm removed from service and companion cross-arms outdoors but not in service were examined. The evaluation of electrical performance was based on flashover voltage value at AC voltage and standard lightning impulses as well as under dry and wet conditions. The tests were performed in the Mississippi State University High Voltage Laboratory. The obtained flashover voltages show no large differences in electrical strength of fiberglass crossarms removed from service and those stored outdoors. The Added CFO voltage by fiberglass crossarm to the porcelain suspension insulators is presented versus the length of the fiberglass crossarm for dry and wet conditions.

  14. Power Electronic Transformer based Three-Phase PWM AC Drives

    NASA Astrophysics Data System (ADS)

    Basu, Kaushik

    A Transformer is used to provide galvanic isolation and to connect systems at different voltage levels. It is one of the largest and most expensive component in most of the high voltage and high power systems. Its size is inversely proportional to the operating frequency. The central idea behind a power electronic transformer (PET) also known as solid state transformer is to reduce the size of the transformer by increasing the frequency. Power electronic converters are used to change the frequency of operation. Steady reduction in the cost of the semiconductor switches and the advent of advanced magnetic materials with very low loss density and high saturation flux density implies economic viability and feasibility of a design with high power density. Application of PET is in generation of power from renewable energy sources, especially wind and solar. Other important application include grid tied inverters, UPS e.t.c. In this thesis non-resonant, single stage, bi-directional PET is considered. The main objective of this converter is to generate adjustable speed and magnitude pulse width modulated (PWM) ac waveforms from an ac or dc grid with a high frequency ac link. The windings of a high frequency transformer contains leakage inductance. Any switching transition of the power electronic converter connecting the inductive load and the transformer requires commutation of leakage energy. Commutation by passive means results in power loss, decrease in the frequency of operation, distortion in the output voltage waveform, reduction in reliability and power density. In this work a source based partially loss-less commutation of leakage energy has been proposed. This technique also results in partial soft-switching. A series of converters with novel PWM strategies have been proposed to minimize the frequency of leakage inductance commutation. These PETs achieve most of the important features of modern PWM ac drives including 1) Input power factor correction, 2) Common

  15. 21 CFR 880.5510 - Non-AC-powered patient lift.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Non-AC-powered patient lift. 880.5510 Section 880.5510 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5510 Non-AC-powered patient lift. (a) Identification. A non-AC-powered patient lift is...

  16. Development of an analytical tool to study power quality of AC power systems for large spacecraft

    NASA Technical Reports Server (NTRS)

    Kraft, L. Alan; Kankam, M. David

    1991-01-01

    A harmonic power flow program applicable to space power systems with sources of harmonic distortion is described. The algorithm is a modification of the Electric Power Research Institute's HARMFLO program which assumes a three phase, balanced, AC system with loads of harmonic distortion. The modified power flow program can be used with single phase, AC systems. Early results indicate that the required modifications and the models developed are quite adequate for the analysis of a 20 kHz testbed built by General Dynamics Corporation. This is demonstrated by the acceptable correlation of present results with published data. Although the results are not exact, the discrepancies are relatively small.

  17. Development of an analytical tool to study power quality of ac power systems for large spacecraft

    NASA Technical Reports Server (NTRS)

    Kraft, L. A.; Kankam, M. D.

    1991-01-01

    A harmonic power flow program applicable to space power systems with sources of harmonic distortion is described. The algorithm is a modification of Electric Power Research Institute's HARMFLO program which assumes a three-phase, balanced, ac system with loads of harmonic distortion. The modified power flow program can be used with single phase, ac systems. Early results indicate that the required modifications and the models developed are quite adequate for the analysis of a 20-kHz testbed built by General Dynamics Corporation. This is demonstrated by the acceptable correlation of the present results with published data. Although the results are not exact, the discrepancies are relatively small.

  18. Resonant AC power system proof-of-concept test program

    NASA Technical Reports Server (NTRS)

    Wappes, Loran J.

    1986-01-01

    Proof-of-concept testing was performed on a 20-kHz, resonant power system breadboard from 1981 through 1985. The testing began with the evaluation of a single, 1.0-kW resonant inverter and progressed to the testing of breadboard systems with higher power levels and more capability. The final breadboard configuration tested was a 25.0-kW breadboard with six inverters providing power to three user-interface modules over a 50-meter, 20-kHz bus. The breadboard demonstrated the ability to synchronize multiple resonant inverters to power a common bus. Single-phase and three-phase 20-kHz power distribution was demonstrated. Simple conversion of 20-kHz to dc and variable-frequency ac was demonstrated as was bidirectional power flow between 20-kHz and dc. Steady state measurements of efficiency, power-factor tolerance, and conducted emissions and conducted susceptibility were made. In addition, transient responses were recorded for such conditions as start up, shut down, load changes. The results showed the 20-kHz resonant system to be a desirable technology for a spacecraft power management and distribution system with multiple users and a utility-type bus.

  19. Resonant AC power system proof-of-concept test program

    NASA Astrophysics Data System (ADS)

    Wappes, Loran J.

    1986-10-01

    Proof-of-concept testing was performed on a 20-kHz, resonant power system breadboard from 1981 through 1985. The testing began with the evaluation of a single, 1.0-kW resonant inverter and progressed to the testing of breadboard systems with higher power levels and more capability. The final breadboard configuration tested was a 25.0-kW breadboard with six inverters providing power to three user-interface modules over a 50-meter, 20-kHz bus. The breadboard demonstrated the ability to synchronize multiple resonant inverters to power a common bus. Single-phase and three-phase 20-kHz power distribution was demonstrated. Simple conversion of 20-kHz to dc and variable-frequency ac was demonstrated as was bidirectional power flow between 20-kHz and dc. Steady state measurements of efficiency, power-factor tolerance, and conducted emissions and conducted susceptibility were made. In addition, transient responses were recorded for such conditions as start up, shut down, load changes. The results showed the 20-kHz resonant system to be a desirable technology for a spacecraft power management and distribution system with multiple users and a utility-type bus.

  20. 78 FR 32165 - Broadband Over Power Lines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-29

    ... COMMISSION 47 CFR Parts 15 Broadband Over Power Lines AGENCY: Federal Communications Commission. ACTION... Power Line (Access BPL) systems. The Commission concludes that its previous decisions in this proceeding... relating to Access Broadband over Power Line (Access BPL) systems. The Commission concludes that...

  1. Three-phase ac-to-ac series-resonant power converter with a reduced number of thyristors

    SciTech Connect

    Klaassens, J.B.; de Beer, F. )

    1991-07-01

    This paper reports that ac-ac series-resonant converters have been proven to be functional and useful. Power pulse modulation with internal frequencies of tens of kHz and suited for multikilowatt power levels is applied to a series-resonant converter system for generating synthesized multiphase bipolar waveforms with reversible power flow and flow distortion. The use of a series-resonant circuit for power transfer and control obtains natural current commutation of the thyristors and the prevention of excessive stresses on components. Switches are required which have bidirectional current conduction and voltage blocking ability. The conventional series-resonant ac-ac converter applies a total for 24 anti-parallel thyristors. An alternative circuit configuration for the series-resonant ac-ac converter with only 12 thyristors is also presented. The alternative power circuit has three neutrals, related to the polyphase source, the load and the converter, which may be interconnected. If they are connected, the high-frequency component of the source and load currents will flow through the connection between the neutrals. The test results of a converter system generating three-phase sinusoidal input and output waveforms have demonstrated the significant aspects of this type of power interfaces.

  2. Reliability of the emergency ac-power system at nuclear power plants

    SciTech Connect

    Battle, R.E.; Campbell, D.J.; Baranowsky, P.W.

    1982-08-19

    The reliability of the emergency ac-power systems typical of several nuclear power plants was estimated, the costs of several possible improvements was estimated. Fault trees were constructed based on a detailed design review of the emergency ac-power systems of 18 nuclear plants. The failure probabilities used in the fault trees were calculated from extensive historical data collected from Licensee Event Reports (LERs) and from operating experience information obtained from nuclear plant licensees. It was found that there are not one or two improvements that can be made at all plants to significantly increase the industry-average emergency ac-power-system reliability, but the improvements are varied and plant-specific. Estimates of the improvements in reliability and the associated cost are estimated using plant-specific designs and failure probabilities.

  3. A Kalman filtering based control scheme for the improvement of dynamic performance of an AC/DC power system

    NASA Astrophysics Data System (ADS)

    Pecen, Recayi

    In this dissertation, two major accomplishments are achieved. First, the feasibility of a proposed Wyoming to California HVDC system having the ratings of 1000 MW, ±500 kV, 2 kA, 860 miles and 12-pulse bipolar lines is shown for exporting Wyoming's electrical power resources to the heavy loaded western states. The second and the main objective of this dissertation is the development of a Kalman filtering (KF) based control scheme applied to an ac/dc power system. It is shown that the use KF algorithm to estimate some of the system states and utilizing them in a proportional Integral (PI) controller which has a better performance for this specific control scheme have resulted in a better dynamic performance of the proposed system. A set of case studies has shown that the system dynamic performance is improved for most of the contingencies. Ac and dc noisy voltage and current measurements received from the simulated ac/dc power system are sent to the KF estimation algorithm. The noise-separated best estimates of measurable states are computed and sent to a PI controller-based current and firing angle control subsections in order to provide a set of optimum thyristor firing angles for both converter stations during and after contingencies until the normal operation is reached. To evaluate the dynamic performance of the system with the KF algorithm, the model is simulated by a well-known digital simulation package, Electromagnetic Transients DC Program (PSCAD/EMTDC) of Manitoba HVDC Research Center. To apply the KF algorithm, a general, linearized, state-space model of the proposed ac/dc system, appropriate for analyzing both the KF and the electromagnetics transients, is derived first. The derived model enables the representation of an ac power system with two ac sources and one HVDC line with a parallel ac line connecting the two systems. It is shown that system eigenvalues of the discretized system model for a normal operating point are inside the unit circle that

  4. QPSK modulation for AC-power-signal-biased visible light communication system

    NASA Astrophysics Data System (ADS)

    Liu, Yu-Feng; Yeh, Chien-Hung; Chow, Chi-Wai; Liu, Yang

    2013-01-01

    With the integration of light emitting diode (LED), visible light communication (VLC) can provide wireless communication link using the lightning system. Due to the consideration of power efficiency, AC-LED has the design of reducing energy waste with alternating current from the power outlet. In this work, we propose an AC-power-signalbiased system that provides communication on both DC-LED and AC-LED. The bias circuit is designed to combine ACpower signal and the message signal with QPSK format. This driving scheme needs no AC-to-DC converters and it is suitable for driving AC LED. Synchronization is completed to avoid threshold effect of LED.

  5. WATER QUALITY AND TREATMENT CONSIDERATIONS FOR CEMENT-LINED AND A-C PIPE

    EPA Science Inventory

    Both cement mortar lined (CML) and asbestos-cement pipes (A-C) are widely used in many water systems. Cement linings are also commonly applied in-situ after pipe cleaning, usually to prevent the recurrence of red water or tuberculation problems. Unfortunately, little consideratio...

  6. Preliminary study of AC power feeders for AGS booster

    SciTech Connect

    Meth, M.

    1992-07-17

    It has been proposed that the AGS Heavy Ion/Proton Booster be excited directly from the electric power distribution system without intervening an energy storage buffer such as an MG set or a magnetic energy buffer. The average power requirement of the AGS Booster is less than many single-loads presently housed on the lab site. However, the power swing will be the largest single pulsating load on the lab site. The large power swings will impact on the power grid producing utility-line disturbances such as voltage fluctuations and harmonic generation. Thus, it is necessary to carefully evaluate the quality of the electric power system resulting from the interconnection, such that the utility system is not degraded either on the lab site or at LILCO's substation.

  7. Preliminary study of AC power feeders for AGS booster

    SciTech Connect

    Meth, M.

    1992-07-17

    It has been proposed that the AGS Heavy Ion/Proton Booster be excited directly from the electric power distribution system without intervening an energy storage buffer such as an MG set or a magnetic energy buffer. The average power requirement of the AGS Booster is less than many single-loads presently housed on the lab site. However, the power swing will be the largest single pulsating load on the lab site. The large power swings will impact on the power grid producing utility-line disturbances such as voltage fluctuations and harmonic generation. Thus, it is necessary to carefully evaluate the quality of the electric power system resulting from the interconnection, such that the utility system is not degraded either on the lab site or at LILCO`s substation.

  8. Signal pulses superimposed on power supply lines improve electrical control

    SciTech Connect

    1996-06-01

    To manipulate or monitor the operation of cranes and hoists, control engineers typically create control schemes that add numerous conductors, festoon systems, bulky dedicated conductor rails, radio and infrared controls. With modern power line communication equipment, power and intelligence can be combined to: add an unlimited number of control circuits without adding a single wire; have data communication without special cables; and eliminate bulky festoon systems and heavy cable track. Available from US Safety Trolley Corp., a SmartRail system superimposes data and control information on the power line to create a fully functional Local Area Network (LAN). The system network is based on the CEBus protocol EIA/IS-60 and uses a spread spectrum power line carrier technology. The heart of this system is the controller which manages all communication and control tasks. A power line coupling circuit couples the data signal from the controller to the a-c power conductors. These power conductors are often TRI-BAR/FOUR-BAR continuous conductor bar systems or existing conductor bar systems. The combination results in a secure data communications and control system for moving equipment.

  9. Ames Lab 101: Next Generation Power Lines

    ScienceCinema

    Russell, Alan

    2016-07-12

    Ames Laboratory scientist Alan Russell discusses the need to develop new power lines that are stronger and more conductive as a way to address the problem of the nation's aging and inadequate power grid.

  10. 21 CFR 880.5100 - AC-powered adjustable hospital bed.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered adjustable hospital bed. 880.5100... (CONTINUED) MEDICAL DEVICES GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Therapeutic Devices § 880.5100 AC-powered adjustable hospital bed. (a) Identification. An...

  11. Voltage source ac-to-dc converters for high-power transmitters

    NASA Technical Reports Server (NTRS)

    Cormier, R.

    1990-01-01

    This work was done to optimize the design of the components used for the beam power supply, which is a component of the transmitters in the Deep Space Network (DSN). The major findings are: (1) the difference in regulation between a six-pulse and a twelve-pulse converter is at most 7 percent worse for the twelve-pulse converter; (2) the commutation overlap angle of a current source converter equals that of a voltage source converter with continuous line currents; (3) the sources of uncharacteristic harmonics are identified with SPICE simulation; (4) the use of an imperfect phase-shifting transformer for the twelve-pulse converter generates a harmonic at six times the line frequency; and (5) the assumptions usually made in analyzing converters can be relaxed with SPICE simulation. The results demonstrate the suitability of using SPICE simulation to obtain detailed performance predictions of ac-to-dc converters.

  12. Phosphor-in-glass for high-powered remote-type white AC-LED.

    PubMed

    Lin, Hang; Wang, Bo; Xu, Ju; Zhang, Rui; Chen, Hui; Yu, Yunlong; Wang, Yuansheng

    2014-12-10

    The high-powered alternating current (AC) light-emitting diode (LED) (AC-LED), featuring low cost, high energy utilization efficiency, and long service life, will become a new economic growth point in the field of semiconductor lighting. However, flicker of AC-LED in the AC cycles is not healthy for human eyes, and therefore need to be restrained. Herein we report an innovation of persistent "phosphor-in-glass" (PiG) for the remote-type AC-LED, whose afterglow can be efficiently activated by the blue light. It is experimentally demonstrated that the afterglow decay of PiG in the microsecond range can partly compensate the AC time gap. Moreover, the substitution of inorganic glass for organic resins or silicones as the encapsulants would bring out several technological benefits to AC-LED, such as good heat-dissipation, low glare, and excellent physical/chemical stability. PMID:25329651

  13. Phosphor-in-glass for high-powered remote-type white AC-LED.

    PubMed

    Lin, Hang; Wang, Bo; Xu, Ju; Zhang, Rui; Chen, Hui; Yu, Yunlong; Wang, Yuansheng

    2014-12-10

    The high-powered alternating current (AC) light-emitting diode (LED) (AC-LED), featuring low cost, high energy utilization efficiency, and long service life, will become a new economic growth point in the field of semiconductor lighting. However, flicker of AC-LED in the AC cycles is not healthy for human eyes, and therefore need to be restrained. Herein we report an innovation of persistent "phosphor-in-glass" (PiG) for the remote-type AC-LED, whose afterglow can be efficiently activated by the blue light. It is experimentally demonstrated that the afterglow decay of PiG in the microsecond range can partly compensate the AC time gap. Moreover, the substitution of inorganic glass for organic resins or silicones as the encapsulants would bring out several technological benefits to AC-LED, such as good heat-dissipation, low glare, and excellent physical/chemical stability.

  14. Plasma characteristics of argon glow discharge produced by AC power supply operating at low frequencies

    SciTech Connect

    Kongpiboolkid, Watcharapon; Mongkolnavin, Rattachat

    2015-04-24

    Non-thermal properties of Argon glow discharge operating with various operating pressures were measured and presented in this work. The Argon plasma is produced by a parallel conducting electrodes coupling with a high voltage AC power supply. The power supply can generate high AC voltage at various frequencies. The frequencies for the operation are in the range of a few kHz. The system is capable of generating electric field between the two metal electrodes discharge system. The characteristics of plasma produced were measured by optical emission spectroscopy (OES) technique where electron temperature (T{sub e}) and electron number density (n{sub e}) can be determined by line intensity ratio method. The value of electron number density was then determined from the Saha-Eggert equation. Our results show that the electron number density of the discharge obtained is of the order of 10{sup −17} − 10{sup −18} m{sup −3} where the electron temperature is between 1.00−2.00 eV for various operating frequencies used which are in good agreement with similar results published earlier.

  15. Emission lines in the spectra of the RV Tauri stars U Monocerotis and AC Herculis

    NASA Technical Reports Server (NTRS)

    Bopp, B. W.

    1984-01-01

    Strong metallic emission lines have been observed in the spectra of the RV Tauri stars U Mon and AC Her near recent light minima. While these two variables differ in a number of significant respects, the metallic emission spectra are quite similar, resembling the emission that was previously reported as present in the spectrum of R Sct at a deep minimum. The data appear to support Baird's shock-wave model for the spectral behavior of RV Tauri stars.

  16. Transmission Line Adapted Analytical Power Charts Solution

    NASA Astrophysics Data System (ADS)

    Sakala, Japhet D.; Daka, James S. J.; Setlhaolo, Ditiro; Malichi, Alec Pulu

    2016-08-01

    The performance of a transmission line has been assessed over the years using power charts. These are graphical representations, drawn to scale, of the equations that describe the performance of transmission lines. Various quantities that describe the performance, such as sending end voltage, sending end power and compensation to give zero voltage regulation, may be deduced from the power charts. Usually required values are read off and then converted using the appropriate scales and known relationships. In this paper, the authors revisit this area of circle diagrams for transmission line performance. The work presented here formulates the mathematical model that analyses the transmission line performance from the power charts relationships and then uses them to calculate the transmission line performance. In this proposed approach, it is not necessary to draw the power charts for the solution. However the power charts may be drawn for the visual presentation. The method is based on applying derived equations and is simple to use since it does not require rigorous derivations.

  17. Automatic 3D power line reconstruction of multi-angular imaging power line inspection system

    NASA Astrophysics Data System (ADS)

    Zhang, Wuming; Yan, Guangjian; Wang, Ning; Li, Qiaozhi; Zhao, Wei

    2007-06-01

    We develop a multi-angular imaging power line inspection system. Its main objective is to monitor the relative distance between high voltage power line and around objects, and alert if the warning threshold is exceeded. Our multi-angular imaging power line inspection system generates DSM of the power line passage, which comprises ground surface and ground objects, for example trees and houses, etc. For the purpose of revealing the dangerous regions, where ground objects are too close to the power line, 3D power line information should be extracted at the same time. In order to improve the automation level of extraction, reduce labour costs and human errors, an automatic 3D power line reconstruction method is proposed and implemented. It can be achieved by using epipolar constraint and prior knowledge of pole tower's height. After that, the proper 3D power line information can be obtained by space intersection using found homologous projections. The flight experiment result shows that the proposed method can successfully reconstruct 3D power line, and the measurement accuracy of the relative distance satisfies the user requirement of 0.5m.

  18. Circuit for Communication Over Power Lines

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J.; Prokop, Normal F.; Greer, Lawrence C., III; Nappier, Jennifer

    2011-01-01

    Many distributed systems share common sensors and instruments along with a common power line supplying current to the system. A communication technique and circuit has been developed that allows for the simple inclusion of an instrument, sensor, or actuator node within any system containing a common power bus. Wherever power is available, a node can be added, which can then draw power for itself, its associated sensors, and actuators from the power bus all while communicating with other nodes on the power bus. The technique modulates a DC power bus through capacitive coupling using on-off keying (OOK), and receives and demodulates the signal from the DC power bus through the same capacitive coupling. The circuit acts as serial modem for the physical power line communication. The circuit and technique can be made of commercially available components or included in an application specific integrated circuit (ASIC) design, which allows for the circuit to be included in current designs with additional circuitry or embedded into new designs. This device and technique moves computational, sensing, and actuation abilities closer to the source, and allows for the networking of multiple similar nodes to each other and to a central processor. This technique also allows for reconfigurable systems by adding or removing nodes at any time. It can do so using nothing more than the in situ power wiring of the system.

  19. Onboard power line conditioning system for an electric or hybrid vehicle

    DOEpatents

    Kajouke, Lateef A.; Perisic, Milun

    2016-06-14

    A power line quality conditioning system for a vehicle includes an onboard rechargeable direct current (DC) energy storage system and an onboard electrical system coupled to the energy storage system. The energy storage system provides DC energy to drive an electric traction motor of the vehicle. The electrical system operates in a charging mode such that alternating current (AC) energy from a power grid external to the vehicle is converted to DC energy to charge the DC energy storage system. The electrical system also operates in a vehicle-to-grid power conditioning mode such that DC energy from the DC energy storage system is converted to AC energy to condition an AC voltage of the power grid.

  20. Concurrent Wind Cooling in Power Transmission Lines

    SciTech Connect

    Jake P Gentle

    2012-08-01

    Idaho National Laboratory and the Idaho Power Company, with collaboration from Idaho State University, have been working on a project to monitor wind and other environmental data parameters along certain electrical transmission corridors. The combination of both real-time historical weather and environmental data is being used to model, validate, and recommend possibilities for dynamic operations of the transmission lines for power and energy carrying capacity. The planned results can also be used to influence decisions about proposed design criteria for or upgrades to certain sections of the transmission lines.

  1. Power factor control system for ac induction motors

    NASA Technical Reports Server (NTRS)

    Nola, F. J. (Inventor)

    1981-01-01

    A power control circuit for an induction motor is disclosed in which a servo loop is used to control power input by controlling the power factor of motor operation. The power factor is measured by summing the voltage and current derived square wave signals.

  2. Generation mechanism of power line harmonic radiation

    NASA Astrophysics Data System (ADS)

    Kostrov, Alexander; Gushchin, Mikhail; Korobkov, Sergei

    The questions concerning the generation of power line harmonic radiation (PLHR) and magne-tospheric line radiation (MLR) are discussed, including the effective source of high harmonics of 50/60 Hz, and fine dynamic structure of the frequency spectrum of PLHR and MLR. It is shown, that thyristor-based power regulators used by large electrical power consumers produce the periodic sequences of current pulses with duration of about 10 microseconds in a power line. The repetition rate of these pulses is typically 100/120 Hz; the bandwidth is as broad as 100 kHz. For high harmonics of 50/60 Hz, the power line represents an effective traveling-wave (or Beverage) antenna, especially in a frequency range of several kHz corresponding to VLF whistler band in Earth ionosphere and magnetosphere. For the fixed length of the power line, which acts as antenna, radiation directivity diagram in relation to horizon depends of frequency. Hence the spatial separation of whistlers emitted at various frequencies (1-10 kHz in a consid-ered case) is possible, with subsequent propagation of whistlers with different frequencies along different L-shells. Estimations show that the efficiency of power line as travelling-wave antenna can be changed by variations of its load, but not more than twice ("weekend effect"). Since the PLHR can represent the sequence of short electromagnetic bursts, then careful se-lection of frequency-time resolution of the data acquisition equipment is needed. Typically, the time constant of the data recording and processing is too large, and the spectra of PLHR or MLR are characterized by a well-known line structure. At the same time, original bursty structure of PLHR can not be defined. Fine structure of MLR is also discussed. Frequency drift of MLR can be explained by the perturbations of the magnetospheric plasma by intense ULF waves and particle flows affecting the propagation of PLHR. Hence the physical nature of PLHR and MLR is the same, excepting the

  3. Line profile analysis and low temperature AC susceptibility of Cu-Zn ferrites

    SciTech Connect

    Lamani, Ashok. R.; Jayanna, H. S.; Prasanna, G. D.

    2012-06-05

    The Cu{sub 1-x}Zn{sub x}Fe{sub 2}O{sub 4} (x = 0, 0{center_dot}2, 0{center_dot}4, 0{center_dot}6, 0{center_dot}8, 1.0) samples were prepared using double sintering ceramic method by adding Zn{sup 2+} at different concentration. The X-ray line profile analysis were carried out to confirm the spinel phase formation as well as to know the (%) strain in the crystal. The real and imaginary part of a.c. susceptibility measured from 77K to room temperature. The high temperature peak corresponds to magnetic blocking of individual particles, while the low temperature peak is attributed to surface spin-glass freezing. To prove the dynamics of the spin (dis)order in both regimes of freezing and blocking, the frequency dependent ac susceptibility is investigated under a biasing dc field. The frequency shift in the ''frozen'' low-temperature ac susceptibility peak is fitted to a dynamic scaling law which indicates a spin-glass phase. Exchange bias is turned on at low temperature which signifies the existence of a strong core-shell interaction.

  4. Motor power control circuit for ac induction motors

    NASA Technical Reports Server (NTRS)

    Nola, F. J. (Inventor)

    1983-01-01

    A motor power control of the type which functions by controlling the power factor wherein one of the parameters of power factor current on time is determined by the on time of a triac through which current is supplied to the motor. By means of a positive feedback circuit, a wider range of control is effected.

  5. Improved transistorized AC motor controller for battery powered urban electric passenger vehicles

    NASA Technical Reports Server (NTRS)

    Peak, S. C.

    1982-01-01

    An ac motor controller for an induction motor electric vehicle drive system was designed, fabricated, tested, evaluated, and cost analyzed. A vehicle performance analysis was done to establish the vehicle tractive effort-speed requirements. These requirements were then converted into a set of ac motor and ac controller requirements. The power inverter is a three-phase bridge using power Darlington transistors. The induction motor was optimized for use with an inverter power source. The drive system has a constant torque output to base motor speed and a constant horsepower output to maximum speed. A gear shifting transmission is not required. The ac controller was scaled from the base 20 hp (41 hp peak) at 108 volts dec to an expanded horsepower and battery voltage range. Motor reversal was accomplished by electronic reversal of the inverter phase sequence. The ac controller can also be used as a boost chopper battery charger. The drive system was tested on a dynamometer and results are presented. The current-controlled pulse width modulation control scheme yielded improved motor current waveforms. The ac controller favors a higher system voltage.

  6. Development of AC and DC Power Supply Direct Interface Converter

    NASA Astrophysics Data System (ADS)

    Kato, Koji; Itoh, Jun-Ichi

    This paper proposes a novel control method for a direct interface converter for management of the energy flow in either an AC or DC supply. The proposed converter is constructed based on an indirect matrix converter. Therefore a proposed control strategy is based on an indirect control method with a triangular carrier wave. The basic operation of the proposed control method is confirmed by experimental results. In addition, this paper also proposes a commutation error compensation method of an output voltage error and an input current error for an indirect matrix converter. In the proposed method, the output voltage and input current error by the commutation can be compensated at the same time, because the PWM pulse of each switch is directly compensated. The validity of the proposed method is confirmed by experimental results. Those results prove that the proposed compensation method can decrease total harmonic distortion (THD) of the input and output current.

  7. Non-oxidized porous silicon-based power AC switch peripheries

    PubMed Central

    2012-01-01

    We present in this paper a novel application of porous silicon (PS) for low-power alternating current (AC) switches such as triode alternating current devices (TRIACs) frequently used to control small appliances (fridge, vacuum cleaner, washing machine, coffee makers, etc.). More precisely, it seems possible to benefit from the PS electrical insulation properties to ensure the OFF state of the device. Based on the technological aspects of the most commonly used AC switch peripheries physically responsible of the TRIAC blocking performances (leakage current and breakdown voltage), we suggest to isolate upper and lower junctions through the addition of a PS layer anodically etched from existing AC switch diffusion profiles. Then, we comment the voltage capability of practical samples emanating from the proposed architecture. Thanks to the characterization results of simple Al-PS-Si(P) structures, the experimental observations are interpreted, thus opening new outlooks in the field of AC switch peripheries. PMID:23057856

  8. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... qualified person with respect to electrical power transmission and distribution). ... 29 Labor 8 2011-07-01 2011-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or...

  9. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... qualified person with respect to electrical power transmission and distribution). ... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or...

  10. 29 CFR 1926.1411 - Power line safety-while traveling under or near power lines with no load.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... qualified person with respect to electrical power transmission and distribution). ... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety-while traveling under or near power lines... CONSTRUCTION Cranes and Derricks in Construction § 1926.1411 Power line safety—while traveling under or...

  11. 33. A.C. PANEL FOR MENTONE POWER HOUSE, P.L. & P. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. A.C. PANEL FOR MENTONE POWER HOUSE, P.L. & P. CO., LOS ANGELES. RETRACED FROM MASSON'S DRAWING NO. C-275. JAN. 20, 1909. SCE drawing no. 52880. - Santa Ana River Hydroelectric System, SAR-3 Powerhouse, San Bernardino National Forest, Redlands, San Bernardino County, CA

  12. System for conveniently providing load testing termination of an AC power source having at least one battery

    NASA Astrophysics Data System (ADS)

    Morell, Wilbert J., III

    1995-05-01

    An AC uninterruptible power source is disclosed that provides multiphase power output signals for actual use and a selectable single phase power output signal for use in testing. The AC uninterruptible power source further comprises at least one battery. The single phase output signal is connected to a dummy load by means of a power switch of the break before make type. The invention further includes the dummy load as preferably having metering capabilities to measure the frequency, current, and voltage parameters of the single phase output signal. The arrangement of the present invention allows for the single phase output to be mated to the dummy load without the need of removing input power to the AC uninterruptible power source so as to reduce, or even eliminate, transient caused failures to the AC uninterruptible power source and to its sensitive load equipment which the power source services.

  13. A system for conveniently providing load testing termination of an AC power source having at least one battery

    NASA Astrophysics Data System (ADS)

    Morrell, Wilbert J., III

    1994-10-01

    An AC uninterruptible power source is disclosed that provides multi-phase power output signals for actual use and a selectable single phase power output signal for use in testing. The AC uninterruptible power source further comprises at least one battery. The single phase output signal is connected to a dummy load by means of a power switch of the break-before-make type. The invention further includes the dummy load as preferably having metering capabilities to measure the frequency, current, and voltage parameters of the single phase output signal. The arrangement of the present invention allows for the single phase output to be mated to the dummy load without the need of removing input power to the AC uninterruptible power source so as to reduce, or even eliminate, transient caused failures to the AC uninterruptible power source and to its sensitive load equipment which the power source services.

  14. Development of a 10 kW High Temperature High Power Density Three-Phase AC-DC-AC SiC Converter

    SciTech Connect

    Ning, Puqi

    2012-01-01

    This paper presents the development and experimental performance of a 10 kW, all SiC, 250 C junction temperature high-power-density three-phase ac-dc-ac converter. The electromagnetic interference filter, thermal system, high temperature package, and gate drive design are discussed in detail. Finally, tests confirming the feasibility and validating the theoretical basis of the prototype converter system are described.

  15. U. H. F. Power Transistors and Lecher Line Oscillators.

    ERIC Educational Resources Information Center

    Howes, R. W.

    1980-01-01

    Describes the use of transistors instead of valves for Lecher line and radiation demonstrations. Two oscillator circuits which provide power for Lecher line use are described. Impedance of Lecher line is also discussed. (HM)

  16. Apparatus and Method for Communication over Power Lines

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor); Greer, Lawrence C., III (Inventor); Nappier, Jennifer M. (Inventor)

    2015-01-01

    An apparatus and method are provided for communicating over power lines. The apparatus includes a coupling modem that is situated between a power line and a device. The coupling modem is configured to demodulate a signal received from the power line into a sine signal and a cosine signal. The coupling modem is also configured to modulate a communicated bit stream received from the device into a transmitted signal in order to impose the transmitted signal onto the power line.

  17. Analysis and Experimental Evaluation of Power Line Transmission Parameters for Power Line Communication

    NASA Astrophysics Data System (ADS)

    Mlynek, P.; Misurec, J.; Koutny, M.; Fujdiak, R.; Jedlicka, T.

    2015-04-01

    The article describes a way of evaluating the power line channel frequency response and input impedance by means of the linear time-invariant (LTI) power line generator. Two possible methods are introduced for the calculation of primary parameters: the first method depends on the physical realization and physical dimension of the cable, and the second method is derived from the data provided by typical electrical cable manufacturers. Based on these methods, a comparison of transfer functions was made. This is followed by measurement evaluation and numerical verification on a simple topology

  18. Comprehensive review of high power factor ac-dc boost converters for PFC applications

    NASA Astrophysics Data System (ADS)

    De Castro Pereira, Dênis; Da Silva, Márcio Renato; Mateus Silva, Elder; Lessa Tofoli, Fernando

    2015-08-01

    High power factor rectifiers have been consolidated as an effective solution to improve power quality indices in terms of input power factor correction, reduction in the total harmonic distortion of the input current and also regulated dc voltages. Within this context, this subject has motivated the introduction of numerous converter topologies based on classic dc-dc structures associated with novel control techniques, thus leading to the manufacturing of dedicated integrated circuits that allow high input power factor by adding a front-end stage to switch-mode converters. In particular, boost converters in continuous current mode (CCM) are widely employed since they allow obtaining minimised electromagnetic interference levels. This work is concerned with a literature review involving relevant ac-dc single-phase boost-based topologies with high input power factor. The evolution of aspects regarding the conventional boost converter is shown in terms of improved characteristics inherent to other ac-dc boost converters. Additionally, the work intends to be a fast and concise reference to single-phase ac-dc boost converters operating in CCM for engineers, researchers and experts in the field of power electronics by properly analysing and comparing the aforementioned rectifiers.

  19. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 4 2013-07-01 2013-07-01 false Power transmission lines. 644.431 Section 644... Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus... power transmission line and the right of way acquired for its construction is needed for or adaptable...

  20. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 4 2011-07-01 2011-07-01 false Power transmission lines. 644.431 Section 644... Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus... power transmission line and the right of way acquired for its construction is needed for or adaptable...

  1. Inductive energy harvesting from variable frequency and amplitude aircraft power lines

    NASA Astrophysics Data System (ADS)

    Toh, T. T.; Wright, S. W.; Kiziroglou, M. E.; Mueller, J.; Sessinghaus, M.; Yeatman, E. M.; Mitcheson, P. D.

    2014-11-01

    This paper presents a non-contact method of harvesting energy from an aircraft power line that has an AC current of variable amplitude and a frequency range of 360-800 Hz. The current and frequency characteristics of the aircraft power line are dependent on the rotation speed of the electrical generators and will therefore change during a flight. The harvester consists of an inductive coil with a ferrite core, which is interfaced to a rectifier, step-down regulator and supercapacitor. A prototype system was constructed to demonstrate reliable output voltage regulation across a supercapacitor that will supply a peak power of 100 mW under duty cycled load conditions. The system could fully charge a 40 mF supercapacitor to 3.3 V in 78 s from a power line current of 1.5 Arms at 650 Hz.

  2. A novel wireless power and data transmission AC to DC converter for an implantable device.

    PubMed

    Liu, Jhao-Yan; Tang, Kea-Tiong

    2013-01-01

    This article presents a novel AC to DC converter implemented by standard CMOS technology, applied for wireless power transmission. This circuit combines the functions of the rectifier and DC to DC converter, rather than using the rectifier to convert AC to DC and then supplying the required voltage with regulator as in the transitional method. This modification can reduce the power consumption and the area of the circuit. This circuit also transfers the loading condition back to the external circuit by the load shift keying(LSK), determining if the input power is not enough or excessive, which increases the efficiency of the total system. The AC to DC converter is fabricated with the TSMC 90nm CMOS process. The circuit area is 0.071mm(2). The circuit can produce a 1V DC voltage with maximum output current of 10mA from an AC input ranging from 1.5V to 2V, at 1MHz to 10MHz. PMID:24110077

  3. A novel wireless power and data transmission AC to DC converter for an implantable device.

    PubMed

    Liu, Jhao-Yan; Tang, Kea-Tiong

    2013-01-01

    This article presents a novel AC to DC converter implemented by standard CMOS technology, applied for wireless power transmission. This circuit combines the functions of the rectifier and DC to DC converter, rather than using the rectifier to convert AC to DC and then supplying the required voltage with regulator as in the transitional method. This modification can reduce the power consumption and the area of the circuit. This circuit also transfers the loading condition back to the external circuit by the load shift keying(LSK), determining if the input power is not enough or excessive, which increases the efficiency of the total system. The AC to DC converter is fabricated with the TSMC 90nm CMOS process. The circuit area is 0.071mm(2). The circuit can produce a 1V DC voltage with maximum output current of 10mA from an AC input ranging from 1.5V to 2V, at 1MHz to 10MHz.

  4. Electromechanical systems with transient high power response operating from a resonant ac link

    NASA Technical Reports Server (NTRS)

    Burrows, Linda M.; Hansen, Irving G.

    1992-01-01

    The combination of an inherently robust asynchronous (induction) electrical machine with the rapid control of energy provided by a high frequency resonant ac link enables the efficient management of higher power levels with greater versatility. This could have a variety of applications from launch vehicles to all-electric automobiles. These types of systems utilize a machine which is operated by independent control of both the voltage and frequency. This is made possible by using an indirect field-oriented control method which allows instantaneous torque control all four operating quadrants. Incorporating the ac link allows the converter in these systems to switch at the zero crossing of every half cycle of the ac waveform. This zero loss switching of the link allows rapid energy variations to be achieved without the usual frequency proportional switching loss. Several field-oriented control systems were developed under contract to NASA.

  5. A study of some features of ac and dc electric power systems for a space station

    NASA Technical Reports Server (NTRS)

    Hanania, J. I.

    1983-01-01

    This study analyzes certain selected topics in rival dc and high frequency ac electric power systems for a Space Station. The interaction between the Space Station and the plasma environment is analyzed, leading to a limit on the voltage for the solar array and a potential problem with resonance coupling at high frequencies. Certain problems are pointed out in the concept of a rotary transformer, and further development work is indicated in connection with dc circuit switching, special design of a transmission conductor for the ac system, and electric motors. The question of electric shock hazards, particularly at high frequency, is also explored. and a problem with reduced skin resistance and therefore increased hazard with high frequency ac is pointed out. The study concludes with a comparison of the main advantages and disadvantages of the two rival systems, and it is suggested that the choice between the two should be made after further studies and development work are completed.

  6. Automatic Railway Power Line Extraction Using Mobile Laser Scanning Data

    NASA Astrophysics Data System (ADS)

    Zhang, Shanxin; Wang, Cheng; Yang, Zhuang; Chen, Yiping; Li, Jonathan

    2016-06-01

    Research on power line extraction technology using mobile laser point clouds has important practical significance on railway power lines patrol work. In this paper, we presents a new method for automatic extracting railway power line from MLS (Mobile Laser Scanning) data. Firstly, according to the spatial structure characteristics of power-line and trajectory, the significant data is segmented piecewise. Then, use the self-adaptive space region growing method to extract power lines parallel with rails. Finally use PCA (Principal Components Analysis) combine with information entropy theory method to judge a section of the power line whether is junction or not and which type of junction it belongs to. The least squares fitting algorithm is introduced to model the power line. An evaluation of the proposed method over a complicated railway point clouds acquired by a RIEGL VMX450 MLS system shows that the proposed method is promising.

  7. Improved SCR ac Motor Controller for Battery Powered Urban Electric Vehicles

    NASA Technical Reports Server (NTRS)

    Latos, T. S.

    1982-01-01

    An improved ac motor controller, which when coupled to a standard ac induction motor and a dc propulsion battery would provide a complete electric vehicle power train with the exception of the mechanical transmission and drive wheels was designed. In such a system, the motor controller converts the dc electrical power available at the battery terminals to ac electrical power for the induction motor in response to the drivers commands. The performance requirements of a hypothetical electric vehicle with an upper weight bound of 1590 kg (3500 lb) were used to determine the power rating of the controller. Vehicle acceleration capability, top speed, and gradeability requisites were contained in the Society of Automotive Engineers (SAE) Schedule 227a(d) driving cycle. The important capabilities contained in this driving cycle are a vehicle acceleration requirement of 0 to 72.4 kmph (0 to 45 mph) in 28 seconds a top speed of 88.5 kmph (55 mph), and the ability to negotiate a 10% grade at 48 kmph (30 mph). A 10% grade is defined as one foot of vertical rise per 10 feet of horizontal distance.

  8. Scaling behaviors and novel creep motion of ac-driven flux lines in type II superconductor with random point pins

    NASA Astrophysics Data System (ADS)

    Cao, Wei-Ping; Luo, Meng-Bo; Hu, Xiao

    2012-01-01

    We performed Langevin dynamics simulations for the ac-driven flux lines in a type II superconductor with random point-like pinning centers. Scaling properties of flux-line velocity with respect to an instantaneous driving force of small frequency and around the critical dc depinning force are revealed successfully, which provides precise estimates on dynamic critical exponents. From the scaling function, we derive a creep law associated with activation by regular shaking. The effective energy barrier vanishes at the critical dc depinning point in a square-root way when the instantaneous driving force increases. The frequency plays a similar role to temperature in conventional creep motions, but in a nontrivial way governed by the critical exponents. We have also performed systematic finite-size scaling analysis for flux-line velocity in transient processes with dc driving, which provide estimates on critical exponents in good agreement with those derived with ac driving. The scaling law is checked successfully.

  9. Very low noise AC/DC power supply systems for large detector arrays

    NASA Astrophysics Data System (ADS)

    Arnaboldi, C.; Baù, A.; Carniti, P.; Cassina, L.; Giachero, A.; Gotti, C.; Maino, M.; Passerini, A.; Pessina, G.

    2015-12-01

    In this work, we present the first part of the power supply system for the CUORE and LUCIFER arrays of bolometric detectors. For CUORE, it consists of AC/DC commercial power supplies (0-60 V output) followed by custom DC/DC modules (48 V input, ±5 V to ±13.5 V outputs). Each module has 3 floating and independently configurable output voltages. In LUCIFER, the AC/DC + DC/DC stages are combined into a commercial medium-power AC/DC source. At the outputs of both setups, we introduced filters with the aim of lowering the noise and to protect the following stages from high voltage spikes that can be generated by the energy stored in the cables after the release of accidental short circuits. Output noise is very low, as required: in the 100 MHz bandwidth the RMS level is about 37 μVRMS (CUORE setup) and 90 μVRMS (LUCIFER setup) at a load of 7 A, with a negligible dependence on the load current. Even more importantly, high frequency switching disturbances are almost completely suppressed. The efficiency of both systems is above 85%. Both systems are completely programmable and monitored via CAN bus (optically coupled).

  10. Nonlinear control of voltage source converters in AC-DC power system.

    PubMed

    Dash, P K; Nayak, N

    2014-07-01

    This paper presents the design of a robust nonlinear controller for a parallel AC-DC power system using a Lyapunov function-based sliding mode control (LYPSMC) strategy. The inputs for the proposed control scheme are the DC voltage and reactive power errors at the converter station and the active and reactive power errors at the inverter station of the voltage-source converter-based high voltage direct current transmission (VSC-HVDC) link. The stability and robust tracking of the system parameters are ensured by applying the Lyapunov direct method. Also the gains of the sliding mode control (SMC) are made adaptive using the stability conditions of the Lyapunov function. The proposed control strategy offers invariant stability to a class of systems having modeling uncertainties due to parameter changes and exogenous inputs. Comprehensive computer simulations are carried out to verify the proposed control scheme under several system disturbances like changes in short-circuit ratio, converter parametric changes, and faults on the converter and inverter buses for single generating system connected to the power grid in a single machine infinite-bus AC-DC network and also for a 3-machine two-area power system. Furthermore, a second order super twisting sliding mode control scheme has been presented in this paper that provides a higher degree of nonlinearity than the LYPSMC and damps faster the converter and inverter voltage and power oscillations.

  11. Nonlinear control of voltage source converters in AC-DC power system.

    PubMed

    Dash, P K; Nayak, N

    2014-07-01

    This paper presents the design of a robust nonlinear controller for a parallel AC-DC power system using a Lyapunov function-based sliding mode control (LYPSMC) strategy. The inputs for the proposed control scheme are the DC voltage and reactive power errors at the converter station and the active and reactive power errors at the inverter station of the voltage-source converter-based high voltage direct current transmission (VSC-HVDC) link. The stability and robust tracking of the system parameters are ensured by applying the Lyapunov direct method. Also the gains of the sliding mode control (SMC) are made adaptive using the stability conditions of the Lyapunov function. The proposed control strategy offers invariant stability to a class of systems having modeling uncertainties due to parameter changes and exogenous inputs. Comprehensive computer simulations are carried out to verify the proposed control scheme under several system disturbances like changes in short-circuit ratio, converter parametric changes, and faults on the converter and inverter buses for single generating system connected to the power grid in a single machine infinite-bus AC-DC network and also for a 3-machine two-area power system. Furthermore, a second order super twisting sliding mode control scheme has been presented in this paper that provides a higher degree of nonlinearity than the LYPSMC and damps faster the converter and inverter voltage and power oscillations. PMID:24906895

  12. Electromechanical systems with transient high power response operating from a resonant AC link

    NASA Technical Reports Server (NTRS)

    Burrows, Linda M.; Hansen, Irving G.

    1992-01-01

    The combination of an inherently robust asynchronous (induction) electrical machine with the rapid control of energy provided by a high frequency resonant AC link enables the efficient management of higher power levels with greater versatility. This could have a variety of applications from launch vehicles to all-electric automobiles. These types of systems utilize a machine which is operated by independent control of both the voltage and frequency. This is made possible by using an indirect field-oriented control method which allows instantaneous torque control in all four operating quadrants. Incorporating the AC link allows the converter in these systems to switch at the zero crossing of every half cycle of the AC waveform. This zero loss switching of the link allows rapid energy variations to be achieved without the usual frequency proportional switching loss. Several field-oriented control systems were developed by LeRC and General Dynamics Space Systems Division under contract to NASA. A description of a single motor, electromechanical actuation system is presented. Then, focus is on a conceptual design for an AC electric vehicle. This design incorporates an induction motor/generator together with a flywheel for peak energy storage. System operation and implications along with the associated circuitry are addressed. Such a system would greatly improve all-electric vehicle ranges over the Federal Urban Driving Cycle (FUD).

  13. Fuzzy based power factor improvement strategy for a multiple connected AC-DC converter fed drive

    NASA Astrophysics Data System (ADS)

    Radhakrishnan, N.; Muthiah, Ramaswamy

    2012-01-01

    The main focus of this paper is to design a Fuzzy based control algorithm to realize an improvement in the input power factor of a multiple connected AC-DC converter fed drive system. It incorporates the role of fuzzy inference principles to generate appropriate PWM pulses for the power switches at the second stage of the power module. The philosophy is developed, with a view to reshape the input current phasor and enables it to align with the supply voltage wave in the perspective of improving the input power factor. The closed loop scheme evaluated using MATLAB based simulation exhibits an enhancement in supply power factor over a range of operating loads in addition to illustrating the speed regulating capability of the drive.

  14. ESBWR response to an extended station blackout/loss of all AC power

    SciTech Connect

    Barrett, A. J.; Marquino, W.

    2012-07-01

    U.S. federal regulations require light water cooled nuclear power plants to cope with Station Blackouts for a predetermined amount of time based on design factors for the plant. U.S. regulations define Station Blackout (SBO) as a loss of the offsite electric power system concurrent with turbine trip and unavailability of the onsite emergency AC power system. According to U.S. regulations, typically the coping period for an SBO is 4 hours and can be as long as 16 hours for currently operating BWR plants. Being able to cope with an SBO and loss of all AC power is required by international regulators as well. The U.S. licensing basis for the ESBWR is a coping period of 72 hours for an SBO based on U.S. NRC requirements for passive safety plants. In the event of an extended SBO (viz., greater than 72 hours), the ESBWR response shows that the design is able to cope with the event for at least 7 days without AC electrical power or operator action. ESBWR is a Generation III+ reactor design with an array of passive safety systems. The ESBWR primary success path for mitigation of an SBO event is the Isolation Condenser System (ICS). The ICS is a passive, closed loop, safety system that initiates automatically on a loss of power. Upon Station Blackout or loss of all AC power, the ICS begins removing decay heat from the Reactor Pressure Vessel (RPV) by (i) condensing the steam into water in heat exchangers located in pools of water above the containment, and (ii) transferring the decay heat to the atmosphere. The condensed water is then returned by gravity to cool the reactor again. The ICS alone is capable of maintaining the ESBWR in a safe shutdown condition after an SBO for an extended period. The fuel remains covered throughout the SBO event. The ICS is able to remove decay heat from the RPV for at least 7 days and maintains the reactor in a safe shutdown condition. The water level in the RPV remains well above the top of active fuel for the duration of the SBO event

  15. Low-energy hydraulic fracturing wastewater treatment via AC powered electrocoagulation with biochar.

    PubMed

    Lobo, Fernanda Leite; Wang, Heming; Huggins, Tyler; Rosenblum, James; Linden, Karl G; Ren, Zhiyong Jason

    2016-05-15

    Produced and flowback waters are the largest byproducts associated with unconventional oil and gas exploration and production. Sustainable and low cost technologies are needed to treat and reuse this wastewater to avoid the environmental problems associated with current management practices (i.e., deep well injection). This study presents a new process to integrate AC-powered electrocoagulation (EC) with granular biochar to dramatically reduce energy use and electrode passivation while achieving high treatment efficiency. Results show achieving a 99% turbidity and TSS removal for the AC-EC-biochar system only used 0.079 kWh/m(3) or 0.15 kWh/kg TSS, which is 70% lower than traditional DC-EC systems and orders of magnitude lower than previous studies. The amount of biochar added positively correlates with energy saving, and further studies are needed to improve organic carbon and salt removal through system integration. PMID:26894291

  16. Low-energy hydraulic fracturing wastewater treatment via AC powered electrocoagulation with biochar.

    PubMed

    Lobo, Fernanda Leite; Wang, Heming; Huggins, Tyler; Rosenblum, James; Linden, Karl G; Ren, Zhiyong Jason

    2016-05-15

    Produced and flowback waters are the largest byproducts associated with unconventional oil and gas exploration and production. Sustainable and low cost technologies are needed to treat and reuse this wastewater to avoid the environmental problems associated with current management practices (i.e., deep well injection). This study presents a new process to integrate AC-powered electrocoagulation (EC) with granular biochar to dramatically reduce energy use and electrode passivation while achieving high treatment efficiency. Results show achieving a 99% turbidity and TSS removal for the AC-EC-biochar system only used 0.079 kWh/m(3) or 0.15 kWh/kg TSS, which is 70% lower than traditional DC-EC systems and orders of magnitude lower than previous studies. The amount of biochar added positively correlates with energy saving, and further studies are needed to improve organic carbon and salt removal through system integration.

  17. 2. LOOKING DOWN THE LINED POWER CANAL AS IT WINDS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. LOOKING DOWN THE LINED POWER CANAL AS IT WINDS ITS WAY TOWARD THE CEMENT MILL Photographer: Walter J. Lubken, November 19, 1907 - Roosevelt Power Canal & Diversion Dam, Parallels Salt River, Roosevelt, Gila County, AZ

  18. An overview of power electronics applications in fuel cell systems: DC and AC converters.

    PubMed

    Ali, M S; Kamarudin, S K; Masdar, M S; Mohamed, A

    2014-01-01

    Power electronics and fuel cell technologies play an important role in the field of renewable energy. The demand for fuel cells will increase as fuel cells become the main power source for portable applications. In this application, a high-efficiency converter is an essential requirement and a key parameter of the overall system. This is because the size, cost, efficiency, and reliability of the overall system for portable applications primarily depend on the converter. Therefore, the selection of an appropriate converter topology is an important and fundamental aspect of designing a fuel cell system for portable applications as the converter alone plays a major role in determining the overall performance of the system. This paper presents a review of power electronics applications in fuel cell systems, which include various topology combinations of DC converters and AC inverters and which are primarily used in fuel cell systems for portable or stand-alone applications. This paper also reviews the switching techniques used in power conditioning for fuel cell systems. Finally, this paper addresses the current problem encountered with DC converters and AC inverter.

  19. An Overview of Power Electronics Applications in Fuel Cell Systems: DC and AC Converters

    PubMed Central

    Ali, M. S.; Kamarudin, S. K.; Masdar, M. S.; Mohamed, A.

    2014-01-01

    Power electronics and fuel cell technologies play an important role in the field of renewable energy. The demand for fuel cells will increase as fuel cells become the main power source for portable applications. In this application, a high-efficiency converter is an essential requirement and a key parameter of the overall system. This is because the size, cost, efficiency, and reliability of the overall system for portable applications primarily depend on the converter. Therefore, the selection of an appropriate converter topology is an important and fundamental aspect of designing a fuel cell system for portable applications as the converter alone plays a major role in determining the overall performance of the system. This paper presents a review of power electronics applications in fuel cell systems, which include various topology combinations of DC converters and AC inverters and which are primarily used in fuel cell systems for portable or stand-alone applications. This paper also reviews the switching techniques used in power conditioning for fuel cell systems. Finally, this paper addresses the current problem encountered with DC converters and AC inverter. PMID:25478581

  20. An overview of power electronics applications in fuel cell systems: DC and AC converters.

    PubMed

    Ali, M S; Kamarudin, S K; Masdar, M S; Mohamed, A

    2014-01-01

    Power electronics and fuel cell technologies play an important role in the field of renewable energy. The demand for fuel cells will increase as fuel cells become the main power source for portable applications. In this application, a high-efficiency converter is an essential requirement and a key parameter of the overall system. This is because the size, cost, efficiency, and reliability of the overall system for portable applications primarily depend on the converter. Therefore, the selection of an appropriate converter topology is an important and fundamental aspect of designing a fuel cell system for portable applications as the converter alone plays a major role in determining the overall performance of the system. This paper presents a review of power electronics applications in fuel cell systems, which include various topology combinations of DC converters and AC inverters and which are primarily used in fuel cell systems for portable or stand-alone applications. This paper also reviews the switching techniques used in power conditioning for fuel cell systems. Finally, this paper addresses the current problem encountered with DC converters and AC inverter. PMID:25478581

  1. AC/DC Power Systems with Applications for future Lunar/Mars base and Crew Exploration Vehicle

    NASA Technical Reports Server (NTRS)

    Chowdhury, Badrul H.

    2005-01-01

    ABSTRACT The Power Systems branch at JSC faces a number of complex issues as it readies itself for the President's initiative on future space exploration beyond low earth orbit. Some of these preliminary issues - those dealing with electric power generation and distribution on board Mars-bound vehicle and that on Lunar and Martian surface may be summarized as follows: Type of prime mover - Because solar power may not be readily available on parts of the Lunar/Mars surface and also during the long duration flight to Mars, the primary source of power will most likely be nuclear power (Uranium fuel rods) with a secondary source of fuel cell (Hydrogen supply). The electric power generation source - With nuclear power being the main prime mover, the electric power generation source will most likely be an ac generator at a yet to be determined frequency. Thus, a critical issue is whether the generator should generate at constant or variable frequency. This will decide what type of generator to use - whether it is a synchronous machine, an asynchronous induction machine or a switched reluctance machine. The type of power distribution system - the distribution frequency, number of wires (3- wire, 4-wire or higher), and ac/dc hybridization. Building redundancy and fault tolerance in the generation and distribution sub-systems so that the system is safe; provides 100% availability to critical loads; continues to operate even with faulted sub-systems; and requires minimal maintenance. This report descril_es results of a summer faculty fellowship spent in the Power Systems Branch with the specific aim of investigating some of the lessons learned in electric power generation and usage from the terrestrial power systems industry, the aerospace industry as well as NASA's on-going missions so as to recommend novel surface and vehicle-based power systems architectures in support of future space exploration initiatives. A hybrid ac/dc architecture with source side and load side

  2. Plasma antennas driven by 5–20 kHz AC power supply

    SciTech Connect

    Zhao, Jiansen Chen, Yuli; Sun, Yang; Wu, Huafeng; Liu, Yue; Yuan, Qiumeng

    2015-12-15

    The experiments described in this work were performed with the aim of introducing a new plasma antenna that was excited by a 5–20 kHz alternating current (AC) power supply, where the antenna was transformed into a U-shape. The results show that the impedance, voltage standing-wave ratio (VSWR), radiation pattern and gain characteristics of the antenna can be controlled rapidly by varying not only the discharge power, but also by varying the discharge frequency in the range from 5 to 20 kHz. When the discharge frequency is adjusted from 10 to 12 kHz, the gain is higher within a relatively broad frequency band and the switch-on time is less than 1 ms when the discharge power is less than 5 W, meaning that the plasma antenna can be turned on and off rapidly.

  3. Lowest of AC-DC power output for electrostrictive polymers energy harvesting systems

    NASA Astrophysics Data System (ADS)

    Meddad, Mounir; Eddiai, Adil; Hajjaji, Abdelowahed; Guyomar, Daniel; Belkhiat, Saad; Boughaleb, Yahia; Chérif, Aida

    2013-11-01

    Advances in technology led to the development of electronic circuits and sensors with extremely low electricity consumption. At the same time, structural health monitoring, technology and intelligent integrated systems created a need for wireless sensors in hard to reach places in aerospace vehicles and large civil engineering structures. Powering sensors with energy harvesters eliminates the need to replace batteries on a regular basis. Scientists have been forced to search for new power source that are able to harvested energy from their surrounding environment (sunlight, temperature gradients etc.). Electrostrictive polymer belonging to the family of electro-active polymers, offer unique properties for the electromechanical transducer technology has been of particular interest over the last few years in order to replace conventional techniques such as those based on piezoelectric or electromagnetic, these materials are highly attractive for their low-density, with large strain capability that can be as high as two orders of magnitude greater than the striction-limited, rigid and fragile electroactive ceramics. Electrostrictive polymers sensors respond to vibration with an ac output signal, one of the most important objectives of the electronic interface is to realize the required AC-DC conversion. The goal of this paper is to design an active, high efficiency power doubler converter for electrostrictive polymers exclusively uses a fraction of the harvested energy to supply its active devices. The simulation results show that it is possible to obtain a maximum efficiency of the AC-DC converter equal to 80%. Premiliminary experimental measurements were performed and the results obtained are in good agreement with simulations.

  4. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 4 2012-07-01 2011-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  5. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 4 2014-07-01 2013-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  6. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  7. Development of an AC power source for CSEM method using full-bridge switching configuration

    NASA Astrophysics Data System (ADS)

    Indrasari, Widyaningrum; Srigutomo, Wahyu; Djamal, Mitra; S, Rahmondia N.

    2015-04-01

    The electromagnetic (EM) method has been widely used in geophysical surveys. It is a non-destructive method that utilizes electromagnetic waves in characterizing subsurface profiles. Generally, EM method can be divided into passive EM and active EM. The passive EM uses the natural electromagnetic field sources, while the active EM or Controlled Source EM (CSEM) uses artificial source to generate electromagnetic wave. In this paper, we present the development of AC power source for CSEM transmitter. As the power source we used AC source with sine wave signal. To satisfy a high power and high voltage in the equipment, we used the full-bridge configuration switching. It works on 990 Hz maximum frequency, and can deliver maximum current of 1.9 A at 620 V. The switching is controlled by microcontroller using Pulse Width Modulation (PWM) and the driver of inverter is built using IGBT. The output frequency can be varied from 1 Hz to 990 Hz. For varied frequencies the harmonic distortion is different due to switching speed. As frequency increase the harmonic distortion also increase. We found that the total harmonic distortion can be reduced to 1 % at the output with 330 Hz.

  8. Critical Length Criterion and the Arc Chain Model for Calculating the Arcing Time of the Secondary Arc Related to AC Transmission Lines

    NASA Astrophysics Data System (ADS)

    Cong, Haoxi; Li, Qingmin; Xing, Jinyuan; Li, Jinsong; Chen, Qiang

    2015-06-01

    The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low-voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines. supported by National Natural Science Foundation of China (Nos. 51277061 and 51420105011)

  9. Simulation analysis of three-phase current type AC-to-DC converter with high power factor

    SciTech Connect

    Okui, Yoshiaki; Yamada, Hajime

    1997-03-01

    A new three-phase current type AC-to-DC converter has been developed by the authors. This paper describes the principle of the circuit operation and the circuit configuration of the AC-to-DC converter controlled by PWM. Simulation analysis of each waveform, such as AC and DC voltages and currents, are calculated by Euler`s method. The simulated values of the total power factor agreed with the measured values within the difference of 5.8% on the condition of full load, 10kW. When the AC side voltage is unbalanced, it is found by simulation that the total harmonic distortion controlled by both feedforward control and AC side current feedback control (proportion gain, k{sub 4} = 1) is restrained at only 38% compared with only feedforward control (k{sub 4} = 0).

  10. An AC motor drive with power factor control for low cost applications

    NASA Astrophysics Data System (ADS)

    Bellar, Maria Dias

    2000-10-01

    The front-end rectifier followed by a pulse-width modulated voltage source inverter (PWM-VSI) has been a well-established power converter configuration for many industrial drives. The increasing costs on the utility usage, due to power quality regulations, and the need to improve the VA capacity of systems, e.g. off-shore drilling rigs, have increased the interest in the development of power electronic equipment with power factor control capability. Electrical motors consume a large amount of the available electrical energy, and this energy tends to increase due to the massive emerging applications of electrical motor drives in appliances and in industrial processes. Therefore, the improvement of the power factor of these low power drive systems, usually in the range from fractional horse-power (hp) to 1 hp, is of particular interest. For these power ratings, the system configuration usually comprises a single-phase to three-phase type of converter with additional circuitry for power factor control (PFC). However, this approach has an impact on the system cost and packaging. In this work, a new concept of integrating motor and power factor controls by using a single-phase to three-phase DSP based six-switch converter topology is presented. Unlike other configurations using extra switch(es) and/or extra boost inductor, in this circuit the boost action, for input current shaping, is done by the motor leakage inductances. The power factor control and inverter operation are performed by applying two modulating signals to the SPWM control logic of the converter. In this dissertation, the converter operation and a proposed control strategy will be explained. Simulation and experimental results for a DSP based induction motor drive will be provided as proof of concept. The feasibility and potential of this configuration for ac motor drive applications will be established. The impact of this scheme on the machine operation will also be discussed.

  11. The system of power on line

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Zhou, Zhen; Yang, Xu; Chen, Qiu Fu

    2004-04-01

    As the digital network is expanding so quickly, many applications are widely used in the social living, especially wireless LAN and IP telephone. The DTE(Data Terminal Equipment) based on Ethernet are also used in many place, these equipments have low power cost, but commonly they have very high requirements in stability and reliability of power supply. This article brings forward a system solution project of long-distance centralize power supply, which can be controlled by network, according to the 802.3af standard. And also presents the key technology in this solution.

  12. A self-powered AC magnetic sensor based on piezoelectric nanogenerator

    NASA Astrophysics Data System (ADS)

    Yu, Aifang; Song, Ming; Zhang, Yan; Kou, Jinzong; Zhai, Junyi; Wang, Zhong Lin

    2014-11-01

    An AC magnetic field, which is a carrier of information, is distributed everywhere and is continuous. How to use and detect this field has been an ongoing topic over the past few decades. Conventional magnetic sensors are usually based on the Hall Effect, the fluxgate, a superconductor quantum interface or magnetoelectric or magnetoresistive sensing. Here, a flexible, simple, low-cost and self-powered active piezoelectric nanogenerator (NG) is successfully demonstrated as an AC magnetic field sensor at room temperature. The amplitude and frequency of a magnetic field can both be accurately sensed by the NG. The output voltage of the NG has a good linearity with a measured magnetic field. The detected minute magnetic field is as low as 1.2 × 10-7 tesla, which is 400 times greater than a commercial magnetic sensor that uses the Hall Effect. In comparison to the existing technologies, an NG is a room-temperature self-powered active sensor that is very simple and very cheap for practical applications.

  13. A self-powered AC magnetic sensor based on piezoelectric nanogenerator.

    PubMed

    Yu, Aifang; Song, Ming; Zhang, Yan; Kou, Jinzong; Zhai, Junyi; Lin Wang, Zhong

    2014-11-14

    An AC magnetic field, which is a carrier of information, is distributed everywhere and is continuous. How to use and detect this field has been an ongoing topic over the past few decades. Conventional magnetic sensors are usually based on the Hall Effect, the fluxgate, a superconductor quantum interface or magnetoelectric or magnetoresistive sensing. Here, a flexible, simple, low-cost and self-powered active piezoelectric nanogenerator (NG) is successfully demonstrated as an AC magnetic field sensor at room temperature. The amplitude and frequency of a magnetic field can both be accurately sensed by the NG. The output voltage of the NG has a good linearity with a measured magnetic field. The detected minute magnetic field is as low as 1.2 × 10(-7) tesla, which is 400 times greater than a commercial magnetic sensor that uses the Hall Effect. In comparison to the existing technologies, an NG is a room-temperature self-powered active sensor that is very simple and very cheap for practical applications. PMID:25333328

  14. A self-powered AC magnetic sensor based on piezoelectric nanogenerator.

    PubMed

    Yu, Aifang; Song, Ming; Zhang, Yan; Kou, Jinzong; Zhai, Junyi; Lin Wang, Zhong

    2014-11-14

    An AC magnetic field, which is a carrier of information, is distributed everywhere and is continuous. How to use and detect this field has been an ongoing topic over the past few decades. Conventional magnetic sensors are usually based on the Hall Effect, the fluxgate, a superconductor quantum interface or magnetoelectric or magnetoresistive sensing. Here, a flexible, simple, low-cost and self-powered active piezoelectric nanogenerator (NG) is successfully demonstrated as an AC magnetic field sensor at room temperature. The amplitude and frequency of a magnetic field can both be accurately sensed by the NG. The output voltage of the NG has a good linearity with a measured magnetic field. The detected minute magnetic field is as low as 1.2 × 10(-7) tesla, which is 400 times greater than a commercial magnetic sensor that uses the Hall Effect. In comparison to the existing technologies, an NG is a room-temperature self-powered active sensor that is very simple and very cheap for practical applications.

  15. Effect of AC target power on AlN film quality

    SciTech Connect

    Knisely, Katherine Grosh, Karl

    2014-09-01

    The influence of alternating current (AC) target power on film stress, roughness, and x-ray diffraction rocking curve full width half maximum (FWHM) was examined for AlN films deposited using S-gun magnetron sputtering on insulative substrates consisting of Si wafers with 575 nm thermal oxide. As the AC target power was increased from 5 to 8 kW, the deposition rate increased from 9.3 to 15.9 A/s, film stress decreased from 81 to −170 MPa, and the rocking curve FWHM increased from 0.98 to 1.03°. AlN film behavior is observed to change with target life; films deposited at 200 kWh target life were approximately 40 MPa more compressive and had 0.02° degree higher rocking curve FWHM values than films deposited at 130 kWh. AlN films deposited in two depositions were compared with films deposited in a single deposition, in order to better characterize the growth behavior and properties of AlN films deposited on an existing AlN film, which is not well understood. Two deposition films, when compared with single deposition films, showed no variation in residual stress trends or grain size behavior, but the average film roughness increased from 0.7 to 1.4 nm and rocking curve FWHM values increased by more than 0.25°.

  16. AC Resonant charger with charge rate unrelated to primary power frequency

    DOEpatents

    Watson, Harold

    1982-01-01

    An AC resonant charger for a capacitive load, such as a PFN, is provided with a variable repetition rate unrelated to the frequency of a multi-phase AC power source by using a control unit to select and couple the phase of the power source to the resonant charger in order to charge the capacitive load with a phase that is the next to begin a half cycle. For optimum range in repetition rate and increased charging voltage, the resonant charger includes a step-up transformer and full-wave rectifier. The next phase selected may then be of either polarity, but is always selected to be of a polarity opposite the polarity of the last phase selected so that the transformer core does not saturate. Thyristors are used to select and couple the correct phase just after its zero crossover in response to a sharp pulse generated by a zero-crossover detector. The thyristor that is turned on then automatically turns off after a full half cycle of its associated phase input. A full-wave rectifier couples the secondary winding of the transformer to the load so that the load capacitance is always charged with the same polarity.

  17. Ac resonant charger with charge rate unrelated to preimary power requency

    DOEpatents

    Not Available

    1979-12-07

    An ac resonant charger for a capacitive load, such as a pulse forming network (PFN), is provided with a variable repetition rate unrelated to the frequency of a multi-phase ac power source by using a control unit to select and couple the phase of the power source to the resonant charger in order to charge the capacitive load with a phase that is the next to begin a half cycle. For optimum range in repetition rate and increased charging voltage, the resonant charger includes a step-up transformer and full-wave rectifier. The next phase selected may then be of either polarity, but is always selected to be of a polarity opposite the polarity of the last phase selected so that the transformer core does not saturate. Thyristors are used to select and couple the correct phase just after its zero crossover in response to a sharp pulse generated by a zero-crossover detector. The thyristor that is turned on then automatically turns off after a full half cycle of its associated phase input. A full-wave rectifier couples the secondary winding of the transformer to the load so that the load capacitance is always charged with the same polarity.

  18. Power Line Integrity Monitor and Repeater

    SciTech Connect

    Svoboda, John

    2005-09-30

    The Idaho National Laboratory (INL) has developed a power system integrity monitor and repeater that provide real time status of the integrity of the physical structure of power poles and transmission towers. It may be applied to other structures, such as pipelines or cell towers, which have multiple segments that can cover hundreds of miles. Sensors and on-board processing provide indication of tampering or impending damage to the structure with information provided to the central operations center or supervisory control and data acquisition (SCADA) for mitigative actions. This software runs on a series of small, inexpensive, low power electronic sensor platforms that are mounted on each tower of an electric power transmission or distribution system for the purpose of communicating system integrity to a central location. The software allows each platform to: 1) interface with sensors that monitor tower integrity, 2) record and analyze events, 3) communicate sensor information to other sensor platforms located on adjacent towers or to a central monitoring location, and 4) derive, conserve, and store platform power from the transmission of electric power.

  19. Power Line Integrity Monitor and Repeater

    2005-09-30

    The Idaho National Laboratory (INL) has developed a power system integrity monitor and repeater that provide real time status of the integrity of the physical structure of power poles and transmission towers. It may be applied to other structures, such as pipelines or cell towers, which have multiple segments that can cover hundreds of miles. Sensors and on-board processing provide indication of tampering or impending damage to the structure with information provided to the centralmore » operations center or supervisory control and data acquisition (SCADA) for mitigative actions. This software runs on a series of small, inexpensive, low power electronic sensor platforms that are mounted on each tower of an electric power transmission or distribution system for the purpose of communicating system integrity to a central location. The software allows each platform to: 1) interface with sensors that monitor tower integrity, 2) record and analyze events, 3) communicate sensor information to other sensor platforms located on adjacent towers or to a central monitoring location, and 4) derive, conserve, and store platform power from the transmission of electric power.« less

  20. Extraction of power lines from mobile laser scanning data

    NASA Astrophysics Data System (ADS)

    Xiang, Qing; Li, Jonathan; Wen, Chenglu; Huang, Pengdi

    2016-03-01

    Modern urban life is becoming increasingly more dependent on reliable electric power supply. Since power outages cause substantial financial losses to producers, distributors and consumers of electric power, it is in the common interest to minimize failures of power lines. In order to detect defects as early as possible and to plan efficiently the maintenance activities, distribution networks are regularly inspected. Carrying out foot patrols or climbing the structures to visually inspect transmission lines and aerial surveys (e.g., digital imaging or most recent airborne laser scanning (ALS) are the two most commonly used methods of power line inspection. Although much faster in comparison to the foot patrol inspection, aerial inspection is more expensive and usually less accurate, in complex urban areas particularly. This paper presents a scientific work that is done in the use of mobile laser scanning (MLS) point clouds for automated extraction of power lines. In the proposed method, 2D power lines are extracted using Hough transform in the projected XOY plane and the 3D power line points are visualized after the point searching. Filtering based on an elevation threshold is applied, which is combined with the vehicle's trajectory in the horizontal section.

  1. Non-Antithrombotic Medical Options in ACS: Old Agents and New Lines on the Horizon

    PubMed Central

    Soukoulis, Victor; Boden, William E.; Smith, Sidney C.; O'Gara, Patrick T.

    2014-01-01

    Acute coronary syndromes (ACS) constitute a spectrum of clinical presentations ranging from unstable angina and non-ST-segment elevation myocardial infarction to ST-segment myocardial infarction. Myocardial ischemia in this context occurs as a result of an abrupt decrease in coronary blood flow and resultant imbalance in the myocardial oxygen supply-demand relationship. Coronary blood flow is further compromised by other mechanisms that increase coronary vascular resistance or reduce coronary driving pressure. The goals of treatment are to decrease myocardial oxygen demand, increase coronary blood flow and oxygen supply, and limit myocardial injury. Treatments are generally divided into “disease-modifying” agents or interventions that improve hard clinical outcomes and other strategies that can reduce ischemia. In addition to traditional drugs such as beta-blockers and inhibitors of the reninangiotensin-aldosterone system, newer agents have expanded the number of molecular pathways targeted for treatment of ACS. Ranolazine, trimetazidine, nicorandil, and ivabradine are medications that have been shown to reduce myocardial ischemia through diverse mechanisms and have been tested in limited fashion in patients with ACS. Attenuating the no-reflow phenomenon and reducing the injury compounded by acute reperfusion after a period of coronary occlusion are active areas of research. Additionally, interventions aimed at ischemic pre- and post-conditioning may be useful means by which to limit myocardial infarct size. Trials are also underway to examine altered metabolic and oxygen-related pathways in ACS. This review will discuss traditional and newer anti-ischemic therapies for patients with ACS, exclusive of revascularization, anti-thrombotic agents, and the use of high-intensity statins. PMID:24902977

  2. Wireless power transfer and fault diagnosis of high-voltage power line via robotic bird

    NASA Astrophysics Data System (ADS)

    Liu, Chunhua; Chau, K. T.; Zhang, Zhen; Qiu, Chun; Li, Wenlong; Ching, T. W.

    2015-05-01

    This paper presents a new idea of wireless power transfer (WPT) and fault diagnosis (FD) of high-voltage power line via robotic bird. The key is to present the conceptual robotic bird with WPT coupling coil for detecting and capturing the energy from the high-voltage power line. If the power line works in normal condition, the robotic bird is able to stand on the power line and extract energy from it. If fault occurs on the power line, the corresponding magnetic field distribution will become different from that in the normal situation. By analyzing the magnetic field distribution of the power line, the WPT to the robotic bird and the FD by the robotic bird are performed and verified.

  3. Accelerator power concepts using isolated transmission lines

    SciTech Connect

    Nunnally, W.C.

    1981-05-01

    This report outlines the rationale and the advantages of using multiple transmission-line sections isolated by transit time and inductance in accelerating high-current (approx. = 10 -kA), short-pulse (less than or equal to 100-ns) particle beams to the multimegavolt level. The main advantages of this system include reducing the number of output switches required per output pulse by nearly an order of magnitude over conventional systems and increasing the system capability for repetition-rate operation. The isolated transmission-line concept is developed, and possible modes of operation are outlined. In addition, a point design of a 10-kA short-pulse accelerator is presented.

  4. Integrating Residential Photovoltaics With Power Lines

    NASA Technical Reports Server (NTRS)

    Borden, C. S.

    1985-01-01

    Report finds rooftop solar-cell arrays feed excess power to electric-utility grid for fee are potentially attractive large-scale application of photovoltaic technology. Presents assessment of breakeven costs of these arrays under variety of technological and economic assumptions.

  5. Power Quality Improvement in Bridgeless Ac-Dc Converter Based Multi-output Switched Mode Power Supply

    NASA Astrophysics Data System (ADS)

    Singh, Shihka; Singh, Bhim; Bhuvaneswari, G.; Bist, Vashist

    2014-12-01

    Computer power supplies are required to have multiple isolated regulated dc voltages with low ripple content and high input power factor at the utility interface. A dc-dc converter is used for obtaining these isolated multi-output dc voltages with excellent regulation. In this paper, a non-isolated ac-dc converter is proposed as the first stage converter to obtain a regulated dc output rather than using a simple uncontrolled diode bridge rectifier at the front end. A dc-dc converter is used at the second stage that has a high frequency transformer with multiple secondary windings to obtain different dc voltage levels at the output. The proposed bridgeless converter based power supply is designed using fundamental design equations, and different component values are calculated. Extensive simulations are carried out to demonstrate the improved performance of the proposed bridgeless converter based multi-output computer power supply at varying source voltages and load conditions. Experimental validation of the power supply is carried on a developed hardware prototype, and the test results are compared with the simulated performance for design verification.

  6. Why an ac magnetic field shifts the irreversibility line in type-II superconductors.

    PubMed

    Brandt, Ernst Helmut; Mikitik, Grigorii P

    2002-07-01

    We show that for a thin superconducting strip placed in a transverse dc magnetic field--the typical geometry of experiments with high-T(c) superconductors--the application of a weak ac magnetic field perpendicular to the dc field generates a dc voltage in the strip. This voltage leads to the decay of the critical currents circulating in the strip, and eventually the equilibrium state of the superconductor is established. This relaxation is not due to thermally activated flux creep but to the "walking" motion of vortices in the two-dimensional critical state of the strip with in-plane ac field. Our theory explains the shaking effect that was used for detecting phase transitions of the vortex lattice in superconductors.

  7. National Maglev initiative: California line electric utility power system requirements

    NASA Astrophysics Data System (ADS)

    Save, Phil

    1994-05-01

    The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

  8. National Maglev initiative: California line electric utility power system requirements

    NASA Technical Reports Server (NTRS)

    Save, Phil

    1994-01-01

    The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

  9. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... licensed users of the radio spectrum. The signals from this operation shall be contained within the... shall be used in the generation of radio frequency currents by power line carrier systems to...

  10. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... licensed users of the radio spectrum. The signals from this operation shall be contained within the... shall be used in the generation of radio frequency currents by power line carrier systems to...

  11. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... licensed users of the radio spectrum. The signals from this operation shall be contained within the... shall be used in the generation of radio frequency currents by power line carrier systems to...

  12. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... licensed users of the radio spectrum. The signals from this operation shall be contained within the... shall be used in the generation of radio frequency currents by power line carrier systems to...

  13. 47 CFR 15.113 - Power line carrier systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... licensed users of the radio spectrum. The signals from this operation shall be contained within the frequency band 9 kHz to 490 kHz. A power line carrier system shall operate on an unprotected,...

  14. 29. CROSSCUT FACILITY PROPERTY AND POWER LINE LOCATION, SHOWING INDIAN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. CROSSCUT FACILITY PROPERTY AND POWER LINE LOCATION, SHOWING INDIAN BEND POND LABELLED 'SETTLING BASIN,' STEAM/DIESEL PLANT AND OTHER FEATURES. 1951 - Crosscut Steam Plant, North side Salt River near Mill Avenue & Washington Street, Tempe, Maricopa County, AZ

  15. Living and Working Safely Around High-Voltage Power Lines.

    SciTech Connect

    United States. Bonneville Power Administration.

    2001-06-01

    High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

  16. Single stage AC-DC converter for Galfenol-based micro-power energy harvesters

    NASA Astrophysics Data System (ADS)

    Cavaroc, Peyton; Curtis, Chandra; Naik, Suketu; Cooper, James

    2014-06-01

    Military based sensor systems are often hindered in operational deployment and/or other capabilities due to limitations in their energy storage elements. Typically operating from lithium based batteries, there is a finite amount of stored energy which the sensor can use to collect and transmit data. As a result, the sensors have reduced sensing and transmission rates. However, coupled with the latest advancements in energy harvesting, these sensors could potentially operate at standard sensing and transition rates as well as dramatically extend lifetimes. Working with the magnetostrictive material Galfenol, we demonstrate the production of enough energy to supplement and recharge a solid state battery thereby overcoming the deficiencies faced by unattended sensors. As with any vibration-based energy harvester, this solution produces an alternating current which needs to be rectified and boosted to a level conducive to recharge the storage element. This paper presents a power converter capable of efficiently converting an ultra-low AC voltage to a solid state charging voltage of 4.1VDC. While we are working with Galfenol transducers as our energy source, this converter may also be applied with any AC producing energy harvester, particularly at operating levels less than 2mW and 200mVAC.

  17. High power dc/dc and dc/ac electrical power conversion techniques developed

    NASA Technical Reports Server (NTRS)

    Berryman, G.; White, W. T.

    1967-01-01

    Small magnetic amplifiers pass square waves through transformers and provide regulation by varying the pulse width on the secondary of the output power transformers. This pulse duration modulation is provided by a control rectifier technique or a phase-shift technique.

  18. Resonant AC power system proof-of-concept test program, volume 2, appendix 1

    NASA Technical Reports Server (NTRS)

    1986-01-01

    This report contains two volumes. The main text (Volume 1) summarizes the tests results and gives a detailed discussion of the response of three early, first generation configurations of ac power system IRAD breadboards to the contracted tests imposed on them. It explains photographs, measurements, and data calculations, as well as any observed anomalies or lessons learned. This volume (No 2, Appendix 1, Test Results and Data), published under separate cover, includes all of the data taken on the 1.0 kW single-phase; 5.0 kW three-phase; and 25.0-kW three-phase system breadboards. The format of this data is raw, i.e., it is a direct copy of the data sheets for the test data notebook.

  19. Transport ac loss of elliptical thin strips with a power-law E(J) relation

    NASA Astrophysics Data System (ADS)

    Jia, Chen-Xi; Chen, Du-Xing; Li, Shuo; Fang, Jin

    2015-10-01

    The transport ac loss Q of an elliptical thin strip of critical current I c with a power-law relation E\\propto {J}n is accurately computed as a function of current amplitude I m and frequency f. The resulting Q({I}m) is normalized to q({i}m) following the Norris critical-state formula, and converted to {q}*({i}m*) at a critical frequency f c based on a transport scaling law. Having a set of {q}*({i}m*) at several values of n as a base, a general expression of {q}*({i}m*,n) is obtained, which can be used to easily calculate q({i}m) for any practical purposes.

  20. Five Mass Power Transmission Line of a Ship Computer Modelling

    NASA Astrophysics Data System (ADS)

    Kazakoff, Alexander Borisoff; Marinov, Boycho Ivanov

    2016-03-01

    The work, presented in this paper, appears to be a natural continuation of the work presented and reported before, on the design of power transmission line of a ship, but with different multi-mass model. Some data from the previous investigations are used as a reference data, mainly from the analytical investigations, for the developed in the previ- ous study, frequency and modal analysis of a five mass model of a power transmission line of a ship. In the paper, a profound dynamic analysis of a concrete five mass dynamic model of the power transmission line of a ship is performed using Finite Element Analysis (FEA), based on the previously recommended model, investigated in the previous research and reported before. Thus, the partially validated by frequency analysis five mass model of a power transmission line of a ship is subjected to dynamic analysis. The objective of the work presented in this paper is dynamic modelling of a five mass transmission line of a ship, partial validation of the model and von Mises stress analysis calculation with the help of Finite Element Analysis (FEA) and comparison of the derived results with the analytically calculated values. The partially validated five mass power transmission line of a ship can be used for definition of many dy- namic parameters, particularly amplitude of displacement, velocity and acceleration, respectively in time and frequency domain. The frequency behaviour of the model parameters is investigated in frequency domain and it corresponds to the predicted one.

  1. Energy harvesting from electric power lines employing the Halbach arrays.

    PubMed

    He, Wei; Li, Ping; Wen, Yumei; Zhang, Jitao; Lu, Caijiang; Yang, Aichao

    2013-10-01

    This paper proposes non-invasive energy harvesters to scavenge alternating magnetic field energy from electric power lines. The core body of a non-invasive energy harvester is a linear Halbach array, which is mounted on the free end of a piezoelectric cantilever beam. The Halbach array augments the magnetic flux density on the side of the array where the power line is placed and significantly lowers the magnetic field on the other side. Consequently, the magnetic coupling strength is enhanced and more alternating magnetic field energy from the current-carrying power line is converted into electrical energy. An analytical model is developed and the theoretical results verify the experimental results. A power of 566 μW across a 196 kΩ resistor is generated from a single wire, and a power of 897 μW across a 212 kΩ resistor is produced from a two-wire power cord carrying opposite currents at 10 A. The harvesters employing Halbach arrays for a single wire and a two-wire power cord, respectively, exhibit 3.9 and 3.2 times higher power densities than those of the harvesters employing conventional layouts of magnets. The proposed devices with strong response to the alternating currents are promising to be applied to electricity end-use environment in electric power systems. PMID:24182155

  2. Waveform magnetic field survey in Russian DC and Swiss AC powered trains: a basis for biologically relevant exposure assessment.

    PubMed

    Ptitsyna, N G; Kopytenko, Y A; Villoresi, G; Pfluger, D H; Ismaguilov, V; Iucci, N; Kopytenko, E A; Zaitzev, D B; Voronov, P M; Tyasto, M I

    2003-12-01

    Recent epidemiological studies suggest a link between transport magnetic fields (MF) and certain adverse health effects. We performed measurements in workplaces of engineers on Russian DC and Swiss AC powered (16.67 Hz) electric trains using a computer based waveform capture system with a 200 Hz sampling rate. MF in DC and AC trains show complex combinations of static and varying components. The most probable levels of quasistatic MF (0.001-0.03 Hz) were in the range 40 microT. Maximum levels of 120 microT were found in DC powered locomotives. These levels are much higher than the geomagnetic field at the site of measurements. MF encountered both in DC and AC powered rail systems showed irregular temporal variability in frequency composition and amplitude characteristics across the whole frequency range studied (0-50 Hz); however, more than 90% of the magnetic field power was concentrated in frequencies AC locomotives, such as the most popular engine Re 4/4 II, the major energy falls around the fundamental frequency 16.67 Hz, with an average magnetic field intensity of about 44 microT; moreover, a significant contribution (about 15%) is due to components below the fundamental frequency. In Russian DC powered trains amplitudes of field variations sharply decrease from static to approximately 3-4 Hz fields; for higher frequencies a tendency of slow decrease is observed up to 50 Hz. For frequencies higher than 1 Hz average amplitudes of magnetic field variations are less than 1 microT; maximum levels reach tens of microtesla. At frequencies lower than 15 Hz, the average magnetic field generated by Swiss AC powered locomotives was approximately 10 times greater than fields observed in Russian DC powered trains.

  3. Comparison of electric field exposure measurement methods under power lines.

    PubMed

    Korpinen, Leena; Kuisti, Harri; Tarao, Hiroo; Pääkkönen, Rauno; Elovaara, Jarmo

    2014-01-01

    The object of the study was to investigate extremely low frequency (ELF) electric field exposure measurement methods under power lines. The authors compared two different methods under power lines: in Method A, the sensor was placed on a tripod; and Method B required the measurer to hold the meter horizontally so that the distance from him/her was at least 1.5 m. The study includes 20 measurements in three places under 400 kV power lines. The authors used two commercial three-axis meters, EFA-3 and EFA-300. In statistical analyses, they did not find significant differences between Methods A and B. However, in the future, it is important to take into account that measurement methods can, in some cases, influence ELF electric field measurement results, and it is important to report the methods used so that it is possible to repeat the measurements.

  4. Reliable, Efficient and Cost-Effective Electric Power Converter for Small Wind Turbines Based on AC-link Technology

    SciTech Connect

    Darren Hammell; Mark Holveck; DOE Project Officer - Keith Bennett

    2006-08-01

    Grid-tied inverter power electronics have been an Achilles heel of the small wind industry, providing opportunity for new technologies to provide lower costs, greater efficiency, and improved reliability. The small wind turbine market is also moving towards the 50-100kW size range. The unique AC-link power conversion technology provides efficiency, reliability, and power quality advantages over existing technologies, and Princeton Power will adapt prototype designs used for industrial asynchronous motor control to a 50kW small wind turbine design.

  5. Electrical Experiments. VT-214-12-2. Part II. A-C Across the Line Control.

    ERIC Educational Resources Information Center

    Connecticut State Dept. of Education, Hartford. Div. of Vocational Education.

    Designed for high school electronics students, this second document in a series of six electrical learning activity packages focuses on alternating current across-the-line control. An introductory section gives the objective for the activities, an introduction, and an outline of the content. The remainder of the activity book is comprised of…

  6. Development of on-line laser power monitoring system

    NASA Astrophysics Data System (ADS)

    Ding, Chien-Fang; Lee, Meng-Shiou; Li, Kuan-Ming

    2016-03-01

    Since the laser was invented, laser has been applied in many fields such as material processing, communication, measurement, biomedical engineering, defense industries and etc. Laser power is an important parameter in laser material processing, i.e. laser cutting, and laser drilling. However, the laser power is easily affected by the environment temperature, we tend to monitor the laser power status, ensuring there is an effective material processing. Besides, the response time of current laser power meters is too long, they cannot measure laser power accurately in a short time. To be more precisely, we can know the status of laser power and help us to achieve an effective material processing at the same time. To monitor the laser power, this study utilize a CMOS (Complementary metal-oxide-semiconductor) camera to develop an on-line laser power monitoring system. The CMOS camera captures images of incident laser beam after it is split and attenuated by beam splitter and neutral density filter. By comparing the average brightness of the beam spots and measurement results from laser power meter, laser power can be estimated. Under continuous measuring mode, the average measuring error is about 3%, and the response time is at least 3.6 second shorter than thermopile power meters; under trigger measuring mode which enables the CMOS camera to synchronize with intermittent laser output, the average measuring error is less than 3%, and the shortest response time is 20 millisecond.

  7. Basic concepts of induced AC voltages on pipelines

    SciTech Connect

    Kirkpatrick, E.L.

    1995-07-01

    The phenomena of induced AC on pipelines sharing common rights-of-way with overhead high-voltage electrical transmission power lines is discussed. Basic concepts and techniques for personnel safety and some pipeline protective measures are reviewed.

  8. Low-power digital communication with unterminated transmission lines

    NASA Astrophysics Data System (ADS)

    Cooperman, Michael; Sieber, Richard W.; Moolenbeek, Rob

    1988-06-01

    Conventional telecommunication techniques are optimized to communicate over long distances (greater than 1 mi), subject to high attenuation, high crosstalk, and other deteriorations in transmission. A trend in telecommunication system architectures is to disperse the previously centralized switching centers, thereby providing switching within a few hundred feet of the subscriber. This creates an opportunity for great improvements in cost and performance for short distance communication links. A technique for low-power digital communication over short transmission lines that exploits this possibility is described. The typical power is more than an order of magnitude lower than the power required with conventional circuits. Associated with this technique are a tenfold reduction in the chip area occupied by the transmission line drivers and the elimination of coupling transformers. The power and chip-area reductions result from terminating the line at the transmitter and maintaining an open circuit at the receiver. These advantages make this line-driving technique particularly suitable for single-chip VLSI systems.

  9. AC electrokinetic drug delivery in dentistry using an interdigitated electrode assembly powered by inductive coupling.

    PubMed

    Ivanoff, Chris S; Wu, Jie Jayne; Mirzajani, Hadi; Cheng, Cheng; Yuan, Quan; Kevorkyan, Stepan; Gaydarova, Radostina; Tomlekova, Desislava

    2016-10-01

    AC electrokinetics (ACEK) has been shown to deliver certain drugs into human teeth more effectively than diffusion. However, using electrical wires to power intraoral ACEK devices poses risks to patients. The study demonstrates a novel interdigitated electrode arrays (IDE) assembly powered by inductive coupling to induce ACEK effects at appropriate frequencies to motivate drugs wirelessly. A signal generator produces the modulating signal, which multiplies with the carrier signal to produce the amplitude modulated (AM) signal. The AM signal goes through the inductive link to appear on the secondary coil, then rectified and filtered to dispose of its carrier signal, and the positive half of the modulating signal appears on the load. After characterizing the device, the device is validated under light microscopy by motivating carboxylate-modified microspheres, tetracycline, acetaminophen, benzocaine, lidocaine and carbamide peroxide particles with induced ACEK effects. The assembly is finally tested in a common dental bleaching application. After applying 35 % carbamide peroxide to human teeth topically or with the IDE at 1200 Hz, 5 Vpp for 20 min, spectrophotometric analysis showed that compared to diffusion, the IDE enhanced whitening in specular optic and specular optic excluded modes by 215 % and 194 % respectively. Carbamide peroxide absorbance by the ACEK group was two times greater than diffusion as measured by colorimetric oxidation-reduction and UV-Vis spectroscopy at 550 nm. The device motivates drugs of variable molecular weight and structure wirelessly. Wireless transport of drugs to intraoral targets under ACEK effects may potentially improve the efficacy and safety of drug delivery in dentistry. PMID:27565821

  10. Remote sensing methods for power line corridor surveys

    NASA Astrophysics Data System (ADS)

    Matikainen, Leena; Lehtomäki, Matti; Ahokas, Eero; Hyyppä, Juha; Karjalainen, Mika; Jaakkola, Anttoni; Kukko, Antero; Heinonen, Tero

    2016-09-01

    To secure uninterrupted distribution of electricity, effective monitoring and maintenance of power lines are needed. This literature review article aims to give a wide overview of the possibilities provided by modern remote sensing sensors in power line corridor surveys and to discuss the potential and limitations of different approaches. Monitoring of both power line components and vegetation around them is included. Remotely sensed data sources discussed in the review include synthetic aperture radar (SAR) images, optical satellite and aerial images, thermal images, airborne laser scanner (ALS) data, land-based mobile mapping data, and unmanned aerial vehicle (UAV) data. The review shows that most previous studies have concentrated on the mapping and analysis of network components. In particular, automated extraction of power line conductors has achieved much attention, and promising results have been reported. For example, accuracy levels above 90% have been presented for the extraction of conductors from ALS data or aerial images. However, in many studies datasets have been small and numerical quality analyses have been omitted. Mapping of vegetation near power lines has been a less common research topic than mapping of the components, but several studies have also been carried out in this field, especially using optical aerial and satellite images. Based on the review we conclude that in future research more attention should be given to an integrated use of various data sources to benefit from the various techniques in an optimal way. Knowledge in related fields, such as vegetation monitoring from ALS, SAR and optical image data should be better exploited to develop useful monitoring approaches. Special attention should be given to rapidly developing remote sensing techniques such as UAVs and laser scanning from airborne and land-based platforms. To demonstrate and verify the capabilities of automated monitoring approaches, large tests in various environments

  11. Limiting electric fields of HVDC overhead power lines.

    PubMed

    Leitgeb, N

    2014-05-01

    As a consequence of the increased use of renewable energy and the now long distances between energy generation and consumption, in Europe, electric power transfer by high-voltage (HV) direct current (DC) overhead power lines gains increasing importance. Thousands of kilometers of them are going to be built within the next years. However, existing guidelines and regulations do not yet contain recommendations to limit static electric fields, which are one of the most important criteria for HVDC overhead power lines in terms of tower design, span width and ground clearance. Based on theoretical and experimental data, in this article, static electric fields associated with adverse health effects are analysed and various criteria are derived for limiting static electric field strengths.

  12. Power line carrier interference from HVDC converter terminals

    SciTech Connect

    Tatro, P.J.; Adamson, K.A. ); Eitzmann, M.A.; Smead, M. . Power Systems Engineering Dept.)

    1993-07-01

    Power line carrier (PLC) equipment typically operates in the frequency range from 25 kHz to 300 kHz. Interference studies for HVDC converters usually concentrate on interference from noise sources within this frequency range. However, operating experience at the Sandy Pond converter terminal has indicated that PLC equipment is also susceptible to interference from sources of power system harmonics below the PLC frequency range. Extensive field testing and analytical studies have shown that each PLC circuit has a resonant frequency below the operating frequency. If excited at this resonant frequency, high voltages may exist within the PLC circuit. The resulting saturation of PLC components leads to local generation of radio frequency (RF) noise that interferes with proper operation of PLC circuits. Sources of power system harmonics in the 3-10 kHz range, such as line commutated dc converters, are potential sources of this type of interference.

  13. Limiting electric fields of HVDC overhead power lines.

    PubMed

    Leitgeb, N

    2014-05-01

    As a consequence of the increased use of renewable energy and the now long distances between energy generation and consumption, in Europe, electric power transfer by high-voltage (HV) direct current (DC) overhead power lines gains increasing importance. Thousands of kilometers of them are going to be built within the next years. However, existing guidelines and regulations do not yet contain recommendations to limit static electric fields, which are one of the most important criteria for HVDC overhead power lines in terms of tower design, span width and ground clearance. Based on theoretical and experimental data, in this article, static electric fields associated with adverse health effects are analysed and various criteria are derived for limiting static electric field strengths. PMID:24573710

  14. Pulse doubling in zigzag-connected autotransformer-based 12-pulse ac-dc converter for power quality improvement

    NASA Astrophysics Data System (ADS)

    Abdollahi, Rohollah

    2012-12-01

    This paper presents a pulse doubling technique in a 12-pulse ac-dc converter which supplies direct torque controlled motor drives (DTCIMDs) in order to have better power quality conditions at the point of common coupling. The proposed technique increases the number of rectification pulses without significant changes in the installations and yields in harmonic reduction in both ac and dc sides. The 12-pulse rectified output voltage is accomplished via two paralleled six-pulse acdc converters each of them consisting of three-phase diode bridge rectifiers. An autotransformer is designed to supply the rectifiers. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications where a six-pulse diode bridge rectifier is being utilized. Independent operation of paralleled diode-bridge rectifiers, i.e. dc-ripple re-injection methodology, requires a Zero Sequence Blocking Transformer (ZSBT). Finally, a tapped interphase reactor is connected at the output of ZSBT to double the pulse numbers of output voltage up to 24 pulses. The aforementioned structure improves power quality criteria at ac mains and makes them consistent with the IEEE-519 standard requirements for varying loads. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6-pulse, 12-pulse, and proposed converters from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 5% for the proposed topology at various loads.

  15. Raptor electrocution on power lines: Current issues and outlook

    USGS Publications Warehouse

    Lehman, Robert N.

    2001-01-01

    Electrocution on power lines is one of many human-caused mortality factors that affect raptors. Cost-effective and relatively simple raptor-safe standards for power line modification and construction have been available for over 25 years. During the 1970s and early 1980s, electric industry efforts to reduce raptor electrocutions were very coordinated and proactive, but predictions about resolving the problem were overly optimistic. Today, raptors continue to be electrocuted, possibly in large numbers. The electrocution problem has not been resolved, partly because of the sheer number of potentially lethal power poles in use and partly because electrocution risks may be more pervasive and sometimes less conspicuous than once believed. Also, responses to the problem by individual utilities have not been uniform, and deregulation of the electric industry during the 1990s may have deflected attention from electrocution issues. To control raptor electrocutions in the future, the industry must increase information sharing and technology transfer, increase efforts to retrofit lethal power poles, and above all ensure that every new and replacement line constructed incorporates raptor-safe standards at all phases of development. Finally, responsibility for the electrocution problem must be shared. Federal, state, and local governments, academic institutions, the conservation community, and the consumer all can play critical roles in an effort that will, by necessity, extend well into the new century.

  16. Power Line Carrier Techniques Applied to Spacecraft Data Handling

    NASA Astrophysics Data System (ADS)

    Bedu, J.-Y.; Morisse, J.; Auvergne, X.; Plancke, P.

    Power Line Carrier (PLC) data transmission coupled with spread spectrum technique is evaluated for onboard satellite purpose. Power Line Carrier present a great advantage in terms of mass saving and integration cost by suppressing the data bus harness. Spread Spectrum techniques allows data transmission inside the power supply noise. This paper will address the major functionality keys of this transmission method and will define the main trades off to conduct. INTRODUCTION A major trend for the next satellite generation stands in the increase of the equipment unit's quantity, of their complexity and of their communication needs. A first approach to reduce the number of links and also the overall mass stands in multiplexing Acq/Ctr on data bus. ALCATEL SPACE with its so-called new avionics 4000 has made a significant step with an intensive use of the data bus : round 140 units on its proprietary OBDH-485 bus and round 10 units on the MIL-STD-1553 data bus for Telecom Geostationnary satellite class. According to this state of the art, the following step is the suppression of the data bus harness by means of Wireless or Power Line Carrier (PLC) techniques that has been identified as a development axis. Many PLC components are available for domestic/industry applications. Nevertheless, transmission levels, operating frequencies, radiation hardening performances of these parts are usually not compatible with space environment constraints. 2/12

  17. System and Battery Charge Control for PV-Powered AC Lighting Systems

    SciTech Connect

    Kern, G.

    1999-04-01

    This report reviews a number of issues specific to stand-alone AC lighting systems. A review of AC lighting technology is presented, which discusses the advantages and disadvantages of various lamps. The best lamps for small lighting systems are compact fluorescent. The best lamps for intermediate-size systems are high- or low-pressure sodium. Specifications for battery charging and load control are provided with the goal of achieving lamp lifetimes on the order of 16,000 to 24,000 hours and battery lifetimes of 4 to 5 years. A rough estimate of the potential domestic and global markets for stand-alone AC lighting systems is presented. DC current injection tests were performed on high-pressure sodium lamps and the test results are presented. Finally, a prototype system was designed and a prototype system controller (with battery charger and DC/AC inverter) was developed and built.

  18. Sub-micrometer particles produced by a low-powered AC electric arc in liquids.

    PubMed

    Jaworski, Jacek A; Fleury, Eric

    2012-01-01

    The article presents the report of the production of composites of sub-micrometer metal particles in matrix consisted of the metal compounds by means of an AC electric arc in water and paraffin solutions using electrodes carbon-metal and metal-metal (metal: Ni, Fe, Co, Cu). The advantage of this method is the low electric power (from 5 to 10 W) needed in comparison to standard DC arc-discharge methods (0.8 to 3 kW). This method enables the production of particles from conductive material also in wide range of temperature and in solvent which could be either transparent to light or opaque. Moreover the solvent can be electrolyte or insulating liquid. The microstructure of the composite layer was investigated by scanning electron microscopy (SEM), Electron Probe Microanalysis (EPMA) and X-ray. During particles production in water metal oxides were created. Additionally using cobalt-copper, nickel-copper as couple electrodes, insoluble in water copper (II) hydroxide crystal grains were created additionally which crystals shape was depended on transition metal. For iron-copper couple electrodes system the copper (II) hydroxide was not formed. Experiments with sequence production of Ni and Fe particles with C electrode assisting in molten paraffin let to obtain both Ni and Fe particles surrounded by paraffin. After solidification the material was insulator but if locally magnetic field influenced on the liquid solution in that place after solidification a new composite was created which was electric current conductor with resistivity around 0.1 omega x m, was attracted by magnetic field and presented magneto resistance around 0.4% in changing magnetic field in a range 150 mT. After mixing the concentrated paraffin with normal paraffin resistivity of the mixture increased and it became photosensitive and created small voltage under light influence. PMID:22524027

  19. Ac loss reduction of multilayer superconducting power transmission cables by using narrow coated conductors

    NASA Astrophysics Data System (ADS)

    Amemiya, Naoyuki; Li, Quan; Ito, Kaoru; Takeuchi, Katsutoku; Nakamura, Taketsune; Okuma, Takeshi

    2011-06-01

    The ac loss characteristics of coated conductors are dominated by the magnetic field component normal to their superconductor layer. Multilayer cables as well as monolayer cables consisting of 4 mm-wide coated conductors (named 4 mm cables) and those consisting of 2 mm-wide coated conductors (named 2 mm cables) were designed, and numerical electromagnetic field analyses were performed in their cross sections to calculate their ac losses. Trapezoidal lateral critical current density Jc distributions with shoulders as well as uniform ones were assumed in coated conductors for the analyses. The former models the degraded Jc near the edges of coated conductors. In the case of the monolayer, the calculated ac losses of the 2 mm cables were comparable to those of the 4 mm cables. In the cases of the multilayers, the calculated ac losses of the 2 mm cables were obviously less than those of the 4 mm cables. The degraded Jc near the edges of coated conductors more seriously affects the ac loss characteristics of the 2 mm cables than those of the 4 mm cables. However, even if we consider the influence of the degraded Jc near the edges of coated conductors, 2 mm-wide coated conductors are more profitable than 4 mm-wide coated conductors in multilayer cables from the viewpoint of ac loss reduction.

  20. Electric power high-voltage transmission lines: Design options, cost, and electric and magnetic field levels

    SciTech Connect

    Stoffel, J.B.; Pentecost, E.D.; Roman, R.D.; Traczyk, P.A.

    1994-11-01

    This report provides background information about (1) the electric and magnetic fields (EMFs) of high-voltage transmission lines at typical voltages and line configurations and (2) typical transmission line costs to assist on alternatives in environmental documents. EMF strengths at 0 {+-} 200 ft from centerline were calculated for ac overhead lines, and for 345 and 230-kV ac underground line and for a {+-}450-kV dc overhead line. Compacting and height sensitivity factors were computed for the variation in EMFs when line conductors are moved closer or raised. Estimated costs for the lines are presented and discussed so that the impact of using alternative strategies for reducing EMF strengths and the implications of implementing the strategies can be better appreciated.

  1. Estimating Magnetic Fields of Homes Near Transmission Lines in the California Power Line Study

    PubMed Central

    Vergara, Ximena P.; Kavet, Robert; Crespi, Catherine M.; Hooper, Chris; Silva, J. Michael; Kheifets, Leeka

    2015-01-01

    The California Power Line Study is a case-control study investigating the relation between residences near transmission lines and risk of childhood leukemia. It includes 5788 childhood leukemia cases and 5788 matched primary controls born between 1986 and 2007. We describe the methodology for estimating magnetic fields at study residences as well as for characterizing sources of uncertainty in these estimates. Birth residences of study subjects were geocoded and their distances to transmission lines were ascertained. 302 residences were deemed sufficiently close to transmission lines to have non-zero magnetic fields attributable to the lines. These residences were visited and detailed data, describing the physical configuration and dimensions of the lines contributing to the magnetic field at the residence, were collected. Phasing, loading, and directional load flow data for years of birth and diagnosis for each subject as well as for the day of site visit were obtained from utilities when available; when yearly average load for a particular year was not available, extrapolated values based on expert knowledge and prediction models were obtained. These data were used to estimate the magnetic fields at the center, closest and farthest point of each residence. We found good correlation between calculated fields and spot measurements of fields taken on site during visits. Our modeling strategies yielded similar calculated field estimates, and they were in high agreement with utility extrapolations. Phasing was known for over 90% of the lines. Important sources of uncertainty included a lack of information on the precise location of residences located within apartment buildings or other complexes. Our findings suggest that we were able to achieve high specificity in exposure assessment, which is essential for examining the association between distance to or magnetic fields from power lines and childhood leukemia risk. PMID:26005950

  2. On-line solid-phase extraction LC-MS/MS for the determination of Ac-SDKP peptide in human plasma from hemodialysis patients.

    PubMed

    Inoue, Koichi; Ikemura, Ayaka; Tsuruta, Yoshinari; Tsutsumiuchi, Kaname; Hino, Tomoaki; Oka, Hisao

    2012-02-01

    We developed a high-throughput method based on on-line solid-phase extraction liquid chromatography tandem mass spectrometry (SPE-LC-MS/MS) to determine N-terminal thymosin-β fragment peptide (N-acetyl-seryl-aspartyl-lysyl-proline, Ac-SDKP) in human plasma samples. Quantification of Ac-SDKP was performed using direct injection for on-line SPE based on C(18), reversed-phase LC separation and stable isotope dilution electrospray ionization-MS/MS in multiple reaction-monitoring (MRM) mode. The Ac-SDKP-(13)C(6), (15)N(2) (m/z 496 → 137) was synthesized for the internal standard. The MRM ion for Ac-SDKP was m/z 488 → 129 (quantitative ion)/226. The limit of detection and lower limit of quantitation were 0.05 and 0.1 ng/mL in standard solution, respectively. Recovery values were 98.3-100.4% with inter-day (relative standard deviation, RSD, 0.4-14.1%) and intra-day (RSD, 0.8-19.7%) assays. This method was applied to the measurement of Ac-SDKP levels in plasma from hemodialyzed subjects. Concentrations were 0.59 ± 0.23 ng/mL (pre-hemodialyzed subjects, n = 9) and 0.44 ± 0.19 ng/mL (post-hemodialyzed subjects, n = 9). All plasma Ac-SDKP levels were decreased by dialysis. Thus, plasma Ac-SDKP was decreased through dialysis in chronic kidney disease. The findings in this study will be useful for the treatment of anemia in chronic kidney disease with dialysis.

  3. Correction: BTI-Tnao38, a new cell line derived from Trichoplusia ni, is permissive for AcMNPV infection and produces high levels of recombinant proteins

    PubMed Central

    2012-01-01

    After publication we discovered an error in the identification of the origin of the cell line reported in our article in BMC Biotechnology (2010, 10:50), entitled "Ao38, a new cell line from eggs of the black witch moth, Ascalapha odorata (Lepidoptera: Noctuidae), is permissive for AcMNPV infection and produces high levels of recombinant proteins". Upon analysis of primary A. odorata cultures, we found that they were contaminated with cells of Trichoplusia ni origin. The origin of the Ao38 cell line was determined as T. ni using three marker genes and the Ao38 cell line was renamed BTI-Tnao38. References to the origin of the cell line as Ascalapha odorata should be replaced with "a cell line of Trichoplusia ni origin". The absence of TNCL virus detection in the BTI-Tnao38 (Ao38) cell line was confirmed using a highly sensitive RT-PCR protocol capable of detecting TNCL virus RNA at approximately 0.018 copies/cell. Because of these observations, we have revised the title of the original article to "Correction: BTI-Tnao38, a new cell line derived from Trichoplusia ni, is permissive for AcMNPV infection and produces high levels of recombinant proteins" and two additional authors were added to reflect their contributions to the analysis of this cell line. PMID:22531032

  4. Alpha Power Increase After Transcranial Alternating Current Stimulation at Alpha Frequency (α-tACS) Reflects Plastic Changes Rather Than Entrainment

    PubMed Central

    Vossen, Alexandra; Gross, Joachim; Thut, Gregor

    2015-01-01

    Background Periodic stimulation of occipital areas using transcranial alternating current stimulation (tACS) at alpha (α) frequency (8–12 Hz) enhances electroencephalographic (EEG) α-oscillation long after tACS-offset. Two mechanisms have been suggested to underlie these changes in oscillatory EEG activity: tACS-induced entrainment of brain oscillations and/or tACS-induced changes in oscillatory circuits by spike-timing dependent plasticity. Objective We tested to what extent plasticity can account for tACS-aftereffects when controlling for entrainment “echoes.” To this end, we used a novel, intermittent tACS protocol and investigated the strength of the aftereffect as a function of phase continuity between successive tACS episodes, as well as the match between stimulation frequency and endogenous α-frequency. Methods 12 healthy participants were stimulated at around individual α-frequency for 11–15 min in four sessions using intermittent tACS or sham. Successive tACS events were either phase-continuous or phase-discontinuous, and either 3 or 8 s long. EEG α-phase and power changes were compared after and between episodes of α-tACS across conditions and against sham. Results α-aftereffects were successfully replicated after intermittent stimulation using 8-s but not 3-s trains. These aftereffects did not reveal any of the characteristics of entrainment echoes in that they were independent of tACS phase-continuity and showed neither prolonged phase alignment nor frequency synchronization to the exact stimulation frequency. Conclusion Our results indicate that plasticity mechanisms are sufficient to explain α-aftereffects in response to α-tACS, and inform models of tACS-induced plasticity in oscillatory circuits. Modifying brain oscillations with tACS holds promise for clinical applications in disorders involving abnormal neural synchrony. PMID:25648377

  5. HIGH FREQUENCY POWER TRANSMISSION LINE FOR CYCLOTRONS AND THE LIKE

    DOEpatents

    Armstrong, W.J.

    1954-04-20

    High-frequency power transmission systems, particularly a stacked capacitance alternating power current transmission line wherein maximum utilization of the effective conductios skin of the line conductors is achieved while enabling a low impedance to be obtained are reported. The transmission line consists of a number of flat metal strips with interleaved dielectric strips. The metal dielectric strips are coiled spirally with the axis of the spiral extending along the length of the strips, and the alternating metal strips at the output end have outwardly extending aligned lugs which are directly strapped together and connected to the respective terminals on the load. At the input end of the transmission line, similarly, the alternate metal strips are directly strapped together and connected to an altereating current source. With the arrangement described each metal strip conducts on both sides, so that the metal strips are designed to have a thickness corresponding to twice the depth of the "skin effect" conducting lamina of each conductor at the source frequency.

  6. Power line harmonic radiation (PLHR) observed by the DEMETER spacecraft

    NASA Astrophysics Data System (ADS)

    NěMec, F.; SantolíK, O.; Parrot, M.; Berthelier, J. J.

    2006-04-01

    Results of a systematic survey of Power Line Harmonic Radiation (PLHR) observed by a recently (June 2004) launched French spacecraft DEMETER are presented. In order to obtain a statistically significant number of events, an automatic identification procedure has been developed and all the available high-resolution data have been processed. Altogether, 58 events have been found in 865 hours of data recorded during the first year of operation. These events form three different classes: with frequency spacing of spectral lines of 50/100 Hz (10 events), with frequency spacing of 60/120 Hz (13 events), with other spacings/not clear cases (35 events). The first two classes of events are discussed in detail, showing that their origin is most probably connected with the radiation from the electric power systems which are magnetically conjugated with the place of observation. Additionally, in more than one half of the cases, the frequencies of PLHR lines well corresponded to the multiples of the power system frequency. The frequency drift of all the observed events was very slow, if observable. The events occurred without any significant preference for low or high geomagnetic activity, although more intense events were observed during disturbed times. Simultaneous observations of electric and magnetic components of PLHR suggest that the waves propagate in the electromagnetic right-hand polarized whistler mode.

  7. A power line data communication interface using spread spectrum technology in home automation

    SciTech Connect

    Shwehdi, M.H.; Khan, A.Z.

    1996-07-01

    Building automation technology is rapidly developing towards more reliable communication systems, devices that control electronic equipments. These equipment if controlled leads to efficient energy management, and savings on the monthly electricity bill. Power Line communication (PLC) has been one of the dreams of the electronics industry for decades, especially for building automation. It is the purpose of this paper to demonstrate communication methods among electronic control devices through an AC power line carrier within the buildings for more efficient energy control. The paper outlines methods of communication over a powerline, namely the X-10 and CE bus. It also introduces the spread spectrum technology as to increase speed to 100--150 times faster than the X-10 system. The powerline carrier has tremendous applications in the field of building automation. The paper presents an attempt to realize a smart house concept, so called, in which all home electronic devices from a coffee maker to a water heater microwave to chaos robots will be utilized by an intelligent network whenever one wishes to do so. The designed system may be applied very profitably to help in energy management for both customer and utility.

  8. Carbon Nanotube-Based Supercapacitors with Excellent ac Line Filtering and Rate Capability via Improved Interfacial Impedance.

    PubMed

    Rangom, Yverick; Tang, Xiaowu Shirley; Nazar, Linda F

    2015-07-28

    We report the fabrication of high-performance, self-standing composite sp(2)-carbon supercapacitor electrodes using single-walled carbon nanotubes (CNTs) as conductive binder. The 3-D mesoporous mesh architecture of CNT-based composite electrodes grants unimpaired ionic transport throughout relatively thick films and allows superior performance compared to graphene-based devices at an ac line frequency of 120 Hz. Metrics of 601 μF/cm(2) with a -81° phase angle and a rate capability (RC) time constant of 199 μs are obtained for thin carbon films. The free-standing carbon films were obtained from a chlorosulfonic acid dispersion and interfaced to stainless steel current collectors with various surface treatments. CNT electrodes were able to cycle at 200 V/s and beyond, still showing a characteristic parallelepipedic cyclic votammetry shape at 1 kV/s. Current densities are measured in excess of 6400 A/g, and the electrodes retain more than 98% capacity after 1 million cycles. These promising results are attributed to a reduction of series resistance in the film through the CNT conductive network and especially to the surface treatment of the stainless steel current collector. PMID:26046685

  9. Carbon Nanotube-Based Supercapacitors with Excellent ac Line Filtering and Rate Capability via Improved Interfacial Impedance.

    PubMed

    Rangom, Yverick; Tang, Xiaowu Shirley; Nazar, Linda F

    2015-07-28

    We report the fabrication of high-performance, self-standing composite sp(2)-carbon supercapacitor electrodes using single-walled carbon nanotubes (CNTs) as conductive binder. The 3-D mesoporous mesh architecture of CNT-based composite electrodes grants unimpaired ionic transport throughout relatively thick films and allows superior performance compared to graphene-based devices at an ac line frequency of 120 Hz. Metrics of 601 μF/cm(2) with a -81° phase angle and a rate capability (RC) time constant of 199 μs are obtained for thin carbon films. The free-standing carbon films were obtained from a chlorosulfonic acid dispersion and interfaced to stainless steel current collectors with various surface treatments. CNT electrodes were able to cycle at 200 V/s and beyond, still showing a characteristic parallelepipedic cyclic votammetry shape at 1 kV/s. Current densities are measured in excess of 6400 A/g, and the electrodes retain more than 98% capacity after 1 million cycles. These promising results are attributed to a reduction of series resistance in the film through the CNT conductive network and especially to the surface treatment of the stainless steel current collector.

  10. Unity power factor converter

    NASA Technical Reports Server (NTRS)

    Wester, Gene W. (Inventor)

    1980-01-01

    A unity power factor converter capable of effecting either inversion (dc-to-dc) or rectification (ac-to-dc), and capable of providing bilateral power control from a DC source (or load) through an AC transmission line to a DC load (or source) for power flow in either direction, is comprised of comparators for comparing the AC current i with an AC signal i.sub.ref (or its phase inversion) derived from the AC ports to generate control signals to operate a switch control circuit for high speed switching to shape the AC current waveform to a sine waveform, and synchronize it in phase and frequency with the AC voltage at the AC ports, by selectively switching the connections to a series inductor as required to increase or decrease the current i.

  11. Investigation into the Effects of Microsecond Power Line Transients on Line-Connected Capacitors

    NASA Technical Reports Server (NTRS)

    Javor, K.

    2000-01-01

    An investigation was conducted into the effect of power-line transients on capacitors used by NASA and installed on platform primary power inputs to avionics. The purpose was to investigate whether capacitor voltage ratings needs to be derated for expected spike potentials. Concerns had been voiced in the past by NASA suppliers that MIL-STD-461 CS06-like requirements were overly harsh and led to physically large capacitors. The author had previously predicted that electrical-switching spike requirements representative of actual power-line transient potentials, durations. and source impedance would require no derating. This investigation bore out that prediction. It was further determined that traditional low source impedance CS06-like transients also will not damage a capacitor, although the spikes themselves are not nearly as well filtered. This report should be used to allay fears that CS06-like requirements drive capacitor voltage derating. Only that derating required by the relatively long duration transients in power quality specification need concern the equipment designer.

  12. Investigation Into The Effects of Microsecond Power Line Transients On Line-Connected Capacitors

    NASA Technical Reports Server (NTRS)

    Javor, Ken

    1999-01-01

    An investigation was conducted into the effect of power-line transients on capacitors used by NASA and installed on platform primary power inputs to avionics. The purpose was to investigate whether capacitor voltage rating needs to be derated for expected spike potentials. Concerns had been voiced in the past by NASA suppliers that MIL-STD-461 CS06-like requirements were overly harsh and led to physically large capacitors. The author had previously predicted that electrical-switching spike requirements representative of actual power-line transient potentials, durations and source impedance would require no derating. This investigation bore out that prediction. It was further determined that traditional low source impedance CS06-like transients also will not damage a capacitor, although the spikes themselves are not nearly as well filtered. This report should be used to allay fears that CS06-like requirements drive capacitor voltage derating. Only that derating required by the relatively long duration transients in power quality specification need concern the equipment designer.

  13. Predicting ice accretion and alleviating galloping on overhead power lines

    NASA Astrophysics Data System (ADS)

    Lu, Mingliang

    2002-04-01

    Both the static and dynamic effects of an ice storm on an overhead power line are investigated fairly comprehensively in this thesis. To determine the static, extreme ice load as well as the combined ice and wind load, a systematic procedure is established based on extensive freezing rain experiments and a Monte Carlo simulation. On the other hand, a dynamic effect---galloping---is examined quite extensively with the objective of better understanding its behavior. A novel add-on device---the hybrid nutation damper (HND)---is proposed to control galloping. Its effectiveness is assessed numerically by using a modified, 3DOF based, galloping software. The present investigations lead to the following findings. (i) Goodwin's simple theoretical model surprisingly predicts, quite accurately, the temporally changing weight of not only a dry ice growth but also a wet ice growth for a fixed, unheated conductor sample. (ii) The maximum ice loading may vary significantly over a power line's planned lifetime because of the randomness of an ice storm and its characteristics as well as the uncertainty involved in identifying the extreme probability distribution of the ice loading. Consequently, backup protection is presently essential for a power line in an ice prone area. (iii) A conductor's torsional flexibility does not appear to affect the growth of the accreted ice weight but it modifies the ice shape significantly. (iv) Three representative ice shapes (a crescent, D-like and icicle pendant) can initiate galloping so that galloping may occur in any icing condition. (v) A noticeable swingback or twist appears to develop only when their respective natural frequencies coincide with the plunge's natural frequency. (vi) A hydraulic jump is the major source of energy dissipation in a nutation damper. A properly induced rotation can significantly enhance a nutation damper's performance. (vii) A hybrid nutation damper has been demonstrated to be a promising means of alleviating

  14. PCF based high power narrow line width pulsed fiber laser

    NASA Astrophysics Data System (ADS)

    Chen, H.; Yan, P.; Xiao, Q.; Wang, Y.; Gong, M.

    2012-09-01

    Based on semiconductor diode seeded multi-stage cascaded fiber amplifiers, we have obtained 88-W average power of a 1063-nm laser with high repetition rate of up to 1.5 MHz and a constant 2-ns pulse duration. No stimulated Brillouin scattering pulse or optical damage occurred although the maximum pulse peak power has exceeded 112 kW. The output laser exhibits excellent beam quality (M2x = 1.24 and M2y = 1.18), associated with a spectral line width as narrow as 0.065 nm (FWHM). Additionally, we demonstrate high polarization extinction ratio of 18.4 dB and good pulse stabilities superior to 1.6 % (RMS).

  15. Power line field sensing to support autonomous navigation of small unmanned aerial vehicles

    NASA Astrophysics Data System (ADS)

    Matthews, John; Bukshpun, Leonid; Pradhan, Ranjit

    2013-06-01

    Autonomous navigation around power lines in a complex urban environment is a critical challenge facing small unmanned aerial vehicles (SUAVs). As part of an ongoing development of an electric and magnetic field sensor system designed to provide SUAVs with the capability to sense and avoid power transmission and distribution lines by monitoring their electric and magnetic field signatures, we have performed field measurements and analysis of power-line signals. We discuss the nature of the power line signatures to be detected, and optimal strategies for detecting these signals amid SUAV platform noise and environmental interference. Based on an analysis of measured power line signals and vehicle noise, we have found that, under certain circumstances, power line harmonics can be detected at greater range than the fundamental. We explain this phenomenon by combining a model of power line signal nonlinearity with the quasi-static electric and magnetic signatures of multiphase power lines.

  16. 29 CFR 1926.1409 - Power line safety (over 350 kV).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 8 2012-07-01 2012-07-01 false Power line safety (over 350 kV). 1926.1409 Section 1926... Construction § 1926.1409 Power line safety (over 350 kV). The requirements of § 1926.1407 and § 1926.1408 apply to power lines over 350 kV except: (a) For power lines at or below 1000 kV, wherever the distance...

  17. 29 CFR 1926.1409 - Power line safety (over 350 kV).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety (over 350 kV). 1926.1409 Section 1926... Construction § 1926.1409 Power line safety (over 350 kV). The requirements of § 1926.1407 and § 1926.1408 apply to power lines over 350 kV except: (a) For power lines at or below 1000 kV, wherever the distance...

  18. 29 CFR 1926.1409 - Power line safety (over 350 kV).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 8 2011-07-01 2011-07-01 false Power line safety (over 350 kV). 1926.1409 Section 1926... Construction § 1926.1409 Power line safety (over 350 kV). The requirements of § 1926.1407 and § 1926.1408 apply to power lines over 350 kV except: (a) For power lines at or below 1000 kV, wherever the distance...

  19. 29 CFR 1926.1409 - Power line safety (over 350 kV).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety (over 350 kV). 1926.1409 Section 1926... Construction § 1926.1409 Power line safety (over 350 kV). The requirements of § 1926.1407 and § 1926.1408 apply to power lines over 350 kV except: (a) For power lines at or below 1000 kV, wherever the distance...

  20. Research of on-line detection system for power capacitor

    NASA Astrophysics Data System (ADS)

    Yao, Junda; Qian, Zheng; Yu, Hao; Xia, Jiuyun

    2016-01-01

    The hidden danger exists in the power capacitor of power system due to long-time operation under the environment of high voltage. Thus, it is possible to induce serious fault, and the on-line detection system is urgently required. In this paper, two methods of the on-line detection system are compared in order to realize the better real-time condition detection. The first method is based on the STM microprocessor with an internal 12 bit A/D converter, which converts analog signals which is arrived from the sample circuit into digital signals, and then the FFT algorithm is used to accomplish the measurement of the voltage and current values of the capacitor. The second method is based on the special electric energy metering IC, which can obtain RMS (Root Mean Square) of voltage and current by processing the sampled data of the voltage and current, and store RMS of voltage and current in its certain registers. The operating condition of the capacitor can be obtained after getting the values of voltage and current. By comparing the measuring results of two methods, the second method could achieve a higher measurement accuracy and more simple construction.

  1. A Line Weighted Frequency Droop Controller for Decentralized Enforcement of Transmission Line Power Flow Constraints in Inverter-Based Networks

    SciTech Connect

    Ainsworth, Nathan G; Grijalva, Prof. Santiago

    2013-01-01

    Recent works have shown that networks of voltagesource inverters implementing frequency droop control may be analyzed as consensus-like networks. Based on this understanding, we show that enforcement of network line power flows can be viewed as an edge-preservation problem in a -disk dynamic interaction graph. Inspired by other works solving similar problems in other domains, we propose a line weighted frequency droop controller such that a network of all active buses implementing this controller enforces the specified line power flow constraints without need for communication. We provide simulation results verifying that our proposed controller limits line power to enforce constraints, and otherwise acts as a traditional droop controller.

  2. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 8 2011-10-01 2011-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be...

  3. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 9 2013-10-01 2013-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be...

  4. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 9 2014-10-01 2014-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be...

  5. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false Electric power transmission line rights-of... General Regulations § 29.21-8 Electric power transmission line rights-of-way. By accepting a right-of-way for a power transmission line, the applicant thereby agrees and consents to comply with and be...

  6. Protection against lightning surge voltages on communication lines and power lines

    SciTech Connect

    Haseborg, J.L.t.; Trinks, H.

    1983-01-01

    Sensitive electronic systems are shielded against electromagnetic interferences (lightning, EMP). The shielding efficiency is reduced by field coupling through apertures and particularly by feeding of interfering currents through cable entries. In case these cables are connected to the inputs of electronic devices, the surge voltages may disturb or even destroy these devices or single electronic components, particularly semiconductors. Special passive protection circuits for communication and power lines against lightning- and EMP-induced surge voltages are developed. The edge steepnesses of the applying surge voltages show values of 2kV/us (lightning) up to 2kV/ns (EMP).

  7. Utility-Scale Power Router: Dynamic Control of Grid Assets Using Direct AC Converter Cells

    SciTech Connect

    2010-09-01

    ADEPT Project: Georgia Tech is developing a cost-effective, utility-scale power router that uses an enhanced transformer to more efficiently direct power on the grid. Existing power routing technologies are too expensive for widespread use, but the ability to route grid power to match real-time demand and power outages would significantly reduce energy costs for utilities, municipalities, and consumers. Georgia Tech is adding a power converter to an existing grid transformer to better control power flows at about 1/10th the cost of existing power routing solutions. Transformers convert the high-voltage electricity that is transmitted through the grid into the low-voltage electricity that is used by homes and businesses. The added converter uses fewer steps to convert some types of power and eliminates unnecessary power storage, among other improvements. The enhanced transformer is more efficient, and it would still work even if the converter fails, ensuring grid reliability.

  8. Study on AC-DC Electrical Conductivities in Warm Dense Matter Generated by Pulsed-power Discharge with Isochoric Vessel

    NASA Astrophysics Data System (ADS)

    Sasaki, Toru; Ohuchi, Takumi; Takahashi, Takuya; Kawaguchi, Yoshinari; Saito, Hirotaka; Miki, Yasutoshi; Takahashi, Kazumasa; Kikuchi, Takashi; Aso, Tsukasa; Harada, Nob.

    2016-03-01

    To observe AC and DC electrical conductivity in warm dense matter (WDM), we have demonstrated to apply the spectroscopic ellipsometry for a pulsed-power discharge with isochoric vessel. At 10 μs from the beginning of discharge, the generated parameters by using pulsed-power discharge with isochoric vessel are 0.1 ρ s (ρ s: solid density) of density and 4000 K of temperature, respectively. The DC electrical conductivity for above parameters is estimated to be 104 S/m. In order to measure the AC electrical conductivity, we have developed a four-detector spectroscopic ellipsometer with a multichannel spectrometer. The multichannel spectrometer, in which consists of a 16-channel photodiode array, a two-stages voltage adder, and a flat diffraction grating, has 10 MHz of the frequency response with covered visible spectrum. For applying the four-detector spectroscopic ellipsometer, we observe the each observation signal evolves the polarized behavior compared to the ratio as I 1/I 2.

  9. Direct current power delivery system and method

    DOEpatents

    Zhang, Di; Garces, Luis Jose; Dai, Jian; Lai, Rixin

    2016-09-06

    A power transmission system includes a first unit for carrying out the steps of receiving high voltage direct current (HVDC) power from an HVDC power line, generating an alternating current (AC) component indicative of a status of the first unit, and adding the AC component to the HVDC power line. Further, the power transmission system includes a second unit for carrying out the steps of generating a direct current (DC) voltage to transfer the HVDC power on the HVDC power line, wherein the HVDC power line is coupled between the first unit and the second unit, detecting a presence or an absence of the added AC component in the HVDC power line, and determining the status of the first unit based on the added AC component.

  10. 10 CFR Appendix Z to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of External Power Supplies

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., of the total real output power produced by a power supply to the real input power required to produce...-voltage output. j. Nameplate input frequency means the AC input frequency of the power supply as specified... supply that is designed to convert line voltage AC input into lower voltage AC output and is able...

  11. New live line tester for porcelain suspension insulators on high-voltage power lines

    SciTech Connect

    Vaillancourt, G.H.; St-Jean, M. ); Bellerive, J.P. ); Jean, C. )

    1994-01-01

    Suspension insulator assemblies known as insulator strings are used in overhead power transmission lines to mechanically support high-voltage conductors while providing adequate insulation to withstand switching and lightning overvoltages. Since the useful life in service of the individual insulator elements making up these strings is hard to predict, they must be verified periodically to insure that adequate line reliability is maintained at all times. Over the years many testing methods have been used for this purpose, each one with its own advantages and disadvantages. Until now at Hydro-Quebec, porcelain insulators had been tested by the buzz method which simply consists of applying a short-circuit to each insulator in a string and listening for a buzz-like sound indicating a good insulator. However, safety considerations that preclude short-circuiting insulators and other disadvantages of that method have led Hydro-Quebec to undertake and complete the development of a new insulator tester. The working principle of this new device is based on the automatic measurement and recording of the electric field along the insulator string which decreases considerably in front of an internally-shorted insulator. The tester is slid along the string while the insulators are counted automatically. The information from tests on up to 200 strings can be stored in the device to be later transferred in a host computer for interpretation and/or permanent storage. The new tester also gives information on voltage distribution along the insulator strings which can be useful for the design of future power transmission lines.

  12. Transport ac loss in a rectangular thin strip with power-law E (J) relation

    NASA Astrophysics Data System (ADS)

    Li, Shuo; Chen, Du-Xing; Fan, Yu; Fang, Jin

    2015-01-01

    Transport ac losses of a rectangular thin strip obeying relation E /Ec =(J /Jc) n with a fixed critical current Ic and n = 5, 10, 20, 30 , and 40 are accurately computed at a fixed frequency f as functions of the current amplitude Im . The results may be interpolated and scaled to those at any values of Ic, f , and 5 ⩽ n ⩽ 40 . Normalized in the same way as that in Norris' analytical formula derived from the critical-state model and converting f to a critical frequency fc , the modeling results may be better compared with the Norris formula and experimental data. A complete set of calculated modeling data are given with necessary formulas to be easily used by experimentalists in any particular case.

  13. Development of an in-line filter to prevent intrusion of NO2 toxic vapors into A/C systems

    NASA Technical Reports Server (NTRS)

    Meneghelli, Barry; Mcnulty, R. J.; Springer, Mike; Lueck, Dale E.

    1995-01-01

    The hypergolic propellant nitrogen tetroxide (N2O4 or NTO) is routinely used in spacecraft launched at Kennedy Space Center (KSC) and Cape Canaveral Air Station (CCAS). In the case of a catastrophic failure of the spacecraft, there would be a release of the unspent propellant in the form of a toxic cloud. Inhalation of this material at downwind concentrations which may be as high as 20 parts per million (ppm) for 30 minutes in duration, may produce irritation to the eyes, nose and respiratory tract. Studies at both KSC and CCAS have shown that the indoor concentrations of N2O4 during a toxic release may range from 1 to 15 ppm and depend on the air change rate (ACR) for a particular building and whether or not the air conditioning (A/C) system has been shut down or left in an operating mode. This project was initiated in order to assess how current A/C systems could be easily modified to prevent personnel from being exposed to toxic vapors. A sample system has been constructed to test the ability of several types of filter material to capture the N2O4 vapors prior to their infiltration into the A/C system. Test results will be presented which compare the efficiencies of standard A/C filters, water wash systems, and chemically impregnated filter material in taking toxic vapors out of the incoming air stream.

  14. Biological effects of power line fields: New York State Power Lines Project Scientific Advisory Panel: Final report

    SciTech Connect

    Ahlbom, A.; Albert, E.N.; Fraser-Smith, A.C.; Grodzinsky, A.J.; Marron, M.T.; Martin, A.O.; Persinger, M.A.; Shelanski, M.L.; Wolpow, E.R.

    1987-07-01

    The New York State Power Lines Project was established to conduct research and to review the scientific literature to determine whether health hazards of electric and magnetic fields are possible. Particular attention was directed to the fields generated by 765-kV overhead transmission lines. The research program provided support to 16 research groups studying human, animal and isolated cell sensitivity to electric and magnetic fields. No effects were found on reproduction, growth or development. Several studies showed no evidence of genetic or chromosomal damage that might lead to inherited effects or cause cancer. While most measurements of behavior and brain function did not demonstrate changes, some did show changes that were small but consistent. Some of these appear to result from changes in body rhythms, and might interfere with normal sleep patterns. There were also changes in pain responses and in the ability of rats to learn. A more serious concern comes from a study of cancer in children suggesting that children with leukemia and brain cancer are more likely to live in homes where there are elevated 60-Hz magnetic field levels. Although much more research is needed before the question whether the magnetic fields actually cause or promote cancer can be resolved, the basis for such an hypothesis is now established. 159 refs., 12 figs., 7 tabs.

  15. Power Line Communication for Automatic Guided Vehicle Using ZigBee

    NASA Astrophysics Data System (ADS)

    Kano, Masaaki; Kobayashi, Hideyuki; Sugiura, Akihiko

    There is an attempt to operate automatic guided vehicles by power line communication(PLC). But, the PLC system has a problem to be disconnected. Then, this paper proposes power line communicatin using ZigBee. We verified that the separated ZigBee PLC line is able to communicate.

  16. Power conversion distribution system using a resonant high-frequency AC link

    NASA Technical Reports Server (NTRS)

    Sood, P. K.; Lipo, T. A.

    1986-01-01

    Static power conversion systems based on a resonant high frequency (HF) link offers a significant reduction in the size and weight of the equipment over that achieved with conventional approaches, especially when multiple sources and loads are to be integrated. A faster system response and absence of audible noise are the other principal characteristics of such systems. A conversion configuration based on a HF link which is suitable for applications requiring distributed power is proposed.

  17. Power Lines and Crops Can Be Good Neighbors

    SciTech Connect

    2010-08-01

    Two of the Pacific Northwest’s greatest economic assets are its wealth of agriculture and its clean and reliable electricity fueled largely by hydropower. Sometimes the two intersect. Transmission lines carrying electricity to the region’s farms, businesses and homes must, of necessity, span large areas where people grow crops and orchards. To ensure a safe and reliable flow of electricity across these expanses, trees and other vegetation must be managed to certain standards. At the same time, the Bonneville Power Administration — which owns and operates three-quarters of the region’s high-voltage transmission — recognizes the importance of our region’s agricultural bounty. We are committed to working with individuals and agricultural communities to facilitate ongoing land-use activities in transmission rights-of-way as long as those uses are compatible with transmission safety and reliability standards. Our goal with vegetation management is to keep you and your property safe while protecting the reliability of our region’s electricity system. By working together, BPA and landowners can protect the system and public safety.

  18. Inspection Robot Based Mobile Sensing and Power Line Tracking for Smart Grid

    PubMed Central

    Byambasuren, Bat-erdene; Kim, Donghan; Oyun-Erdene, Mandakh; Bold, Chinguun; Yura, Jargalbaatar

    2016-01-01

    Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results. PMID:26907274

  19. Inspection Robot Based Mobile Sensing and Power Line Tracking for Smart Grid.

    PubMed

    Byambasuren, Bat-Erdene; Kim, Donghan; Oyun-Erdene, Mandakh; Bold, Chinguun; Yura, Jargalbaatar

    2016-02-19

    Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results.

  20. Inspection Robot Based Mobile Sensing and Power Line Tracking for Smart Grid.

    PubMed

    Byambasuren, Bat-Erdene; Kim, Donghan; Oyun-Erdene, Mandakh; Bold, Chinguun; Yura, Jargalbaatar

    2016-01-01

    Smart sensing and power line tracking is very important in a smart grid system. Illegal electricity usage can be detected by remote current measurement on overhead power lines using an inspection robot. There is a need for accurate detection methods of illegal electricity usage. Stable and correct power line tracking is a very prominent issue. In order to correctly track and make accurate measurements, the swing path of a power line should be previously fitted and predicted by a mathematical function using an inspection robot. After this, the remote inspection robot can follow the power line and measure the current. This paper presents a new power line tracking method using parabolic and circle fitting algorithms for illegal electricity detection. We demonstrate the effectiveness of the proposed tracking method by simulation and experimental results. PMID:26907274

  1. Test Results From a Simulated High-Voltage Lunar Power Transmission Line

    NASA Technical Reports Server (NTRS)

    Birchenough, Arthur; Hervol, David

    2008-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio was modified to simulate high-voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high-frequency ac power to a lunar facility located at a distance.

  2. Test Results from a Simulated High Voltage Lunar Power Transmission Line

    NASA Technical Reports Server (NTRS)

    Birchenough, Arthur; Hervol, David

    2008-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was modified to simulate high voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high frequency AC power to a lunar facility located at a distance.

  3. Design and realization of the low voltage power line carrier channel simulation platform

    NASA Astrophysics Data System (ADS)

    Zhang, Xuhui; Zhang, Liyong; Zou, Bing; Zhang, Xuhai

    2006-11-01

    Proposed a visualized modeling and simulating scheme on the basis of object-oriented software for the power line communication channels. Combined with the research on the theories about transmitting lines, applies a equivalent concentrated parameter model to replace the traditional distributed parameter model of the transmitting lines, and studied the realizing process of the simulation. Constructed the network topology model database, noise model database, typical load model database aiming at the low-voltage power line features. And developed a visual, easy-to-operate power line communication simulation platform under Windows operation system.

  4. a Meteorological Risk Assessment Method for Power Lines Based on GIS and Multi-Sensor Integration

    NASA Astrophysics Data System (ADS)

    Lin, Zhiyong; Xu, Zhimin

    2016-06-01

    Power lines, exposed in the natural environment, are vulnerable to various kinds of meteorological factors. Traditional research mainly deals with the influence of a single meteorological condition on the power line, which lacks of comprehensive effects evaluation and analysis of the multiple meteorological factors. In this paper, we use multiple meteorological monitoring data obtained by multi-sensors to implement the meteorological risk assessment and early warning of power lines. Firstly, we generate meteorological raster map from discrete meteorological monitoring data using spatial interpolation. Secondly, the expert scoring based analytic hierarchy process is used to compute the power line risk index of all kinds of meteorological conditions and establish the mathematical model of meteorological risk. By adopting this model in raster calculator of ArcGIS, we will have a raster map showing overall meteorological risks for power line. Finally, by overlaying the power line buffer layer to that raster map, we will get to know the exact risk index around a certain part of power line, which will provide significant guidance for power line risk management. In the experiment, based on five kinds of observation data gathered from meteorological stations in Guizhou Province of China, including wind, lightning, rain, ice, temperature, we carry on the meteorological risk analysis for the real power lines, and experimental results have proved the feasibility and validity of our proposed method.

  5. Control Quality of a Feedback Control System under Cyclostationary Noise in Power Line Communication

    NASA Astrophysics Data System (ADS)

    Carrizo, Cesar; Kobayashi, Kentaro; Okada, Hiraku; Katayama, Masaaki

    This paper discusses a control system that employs a power line to transfer signals to control the motion of a single machine, and explores the influence of packet losses on the quality of the control. As an example of a controlled system, a controller with a rotary inverted pendulum as a controlled object, is considered. The feedback loop in between is the power line. The control performance is evaluated in the power line cyclostationary noise environment and compared against the performance in a stationary noise environment. As a result, it is confirmed that the power line and its cyclostationary noise features present an advantage against transmission in a channel with stationary noise.

  6. Fast Power Line Detection and Localization Using Steerable Filter for Active Uav Guidance

    NASA Astrophysics Data System (ADS)

    Liu, Y.; Mejias, L.; Li, Z.

    2012-08-01

    In this paper we present a fast power line detection and localisation algorithm as well as propose a high-level guidance architecture for active vision-based Unmanned Aerial Vehicle (UAV) guidance. The detection stage is based on steerable filters for edge ridge detection, followed by a line fitting algorithm to refine candidate power lines in images. The guidance architecture assumes an UAV with an onboard Gimbal camera. We first control the position of the Gimbal such that the power line is in the field of view of the camera. Then its pose is used to generate the appropriate control commands such that the aircraft moves and flies above the lines. We present initial experimental results for the detection stage which shows that the proposed algorithm outperforms two state-of-the-art line detection algorithms for power line detection from aerial imagery.

  7. A new on-chip all-digital three-phase full-bridge dc/ac power inverter with feedforward and frequency control techniques.

    PubMed

    Chen, Jiann-Jong; Kung, Che-Min

    2010-09-01

    The communication speed between components is far from satisfactory. To achieve high speed, simple control system configuration, and low cost, a new on-chip all-digital three-phase dc/ac power inverter using feedforward and frequency control techniques is proposed. The controller of the proposed power inverter, called the shift register, consists of six-stage D-latch flip-flops with a goal of achieving low-power consumption and area efficiency. Variable frequency is achieved by controlling the clocks of the shift register. One advantage regarding the data signal (D) and the common clock (CK) is that, regardless of the phase difference between the two, all of the D-latch flip-flops are capable of delaying data by one CK period. To ensure stability, the frequency of CK must be six times higher than that of D. The operation frequency of the proposed power inverter ranges from 10 Hz to 2 MHz, and the maximum output loading current is 0.8 A. The prototype of the proposed circuit has been fabricated with TSMC 0.35 μm 2P4M CMOS processes. The total chip area is 2.333 x 1.698 mm2. The three-phase dc/ac power inverter is applicable in uninterrupted power supplies, cold cathode fluorescent lamps, and motors, because of its ability to convert the dc supply voltage into the three-phase ac power sources.

  8. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  9. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  10. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  11. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  12. 18 CFR 12.43 - Power and communication lines and gas pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Power and communication lines and gas pipelines. 12.43 Section 12.43 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION, DEPARTMENT OF ENERGY REGULATIONS UNDER THE FEDERAL POWER ACT SAFETY OF WATER...

  13. High power ac/dc variable R dynamic electrical load simulator

    NASA Technical Reports Server (NTRS)

    Joncas, K. P.

    1974-01-01

    A study program was undertaken to investigate various concepts and techniques for identifying and simulating both the steady-state and dynamic characteristics of electrical loads for use during integrated system test and evaluation. The development of hardware capable of providing the simulation capability is discussed. A general purpose simulator was developed with the capability of realizing a variety of models where element values were discretely variable. The different models, each corresponding to real spacecraft equipment, are set up manually for each case by suitable switching and patching. The models are capable of duplicating the dynamic and steady-state response of real loads at full power.

  14. Parametric analysis of EMP induced overvoltages on power lines

    SciTech Connect

    Millard, D.P.; Meliopoulos, A.P. ); Cokkinides, G.J. )

    1988-07-01

    This paper presents parametric results of EMP induced overvoltages on overhead transmission lines. The results have been obtained with an analytical model of an overhead transmission line which accounts for (1) frequency dependent characteristics of lines, (2) EMP coupling to the line conductors, (3) EMP coupling to tower structures, and (4) the grounding structures of the transmission towers. The results indicate that shield or neutral conductors and transmission tower grounding drastically reduce the EMP induced overvoltages on transmission towers. For distribution overhead circuits, the EMP induced overvoltages may be above the basic insulation level. For transmission circuits, it is possible to select design parameters such as to assure that EMP induced overvoltages are below the insulation level of the line.

  15. Millimeter-Gap Magnetically Insulated Transmission Line Power Flow Experiments

    SciTech Connect

    Hutsel, Brian Thomas; Stoltzfus, Brian S.; Fowler, William E.; LeChien, Keith R.; Mazarakis, Michael G.; Moore, James K.; Mulville, Thomas D.; Savage, Mark E.; Stygar, William A.; McKenney, John L.; Jones, Peter A.; MacRunnels, Diego J.; Long, Finis W.; Porter, John L.

    2014-09-01

    An experiment platform has been designed to study vacuum power flow in magnetically insulated transmission lines (MITLs). The platform was driven by the 400-GW Mykonos-V accelerator. The experiments conducted quantify the current loss in a millimeter-gap MITL with respect to vacuum conditions in the MITL for two different gap distances, 1.0 and 1.3 mm. The current loss for each gap was measured for three different vacuum pump down times. As a ride along experiment, multiple shots were conducted with each set of hardware to determine if there was a conditioning effect to increase current delivery on subsequent shots. The experiment results revealed large differences in performance for the 1.0 and 1.3 mm gaps. The 1.0 mm gap resulted in current loss of 40%-60% of peak current. The 1.3 mm gap resulted in current losses of less than 5% of peak current. Classical MITL models that neglect plasma expansion predict that there should be zero current loss, after magnetic insulation is established, for both of these gaps. The experiments result s indicate that the vacuum pressure or pump down time did not have a significant effect on the measured current loss at vacuum pressures between 1e-4 and 1e-5 Torr. Additionally, there was not repeatable evidence of a conditioning effect that reduced current loss for subsequent full-energy shots on a given set of hardware. It should be noted that the experiments conducted likely did not have large loss contributions due to ion emission from the anode due to the relatively small current densi-ties (25-40 kA/cm) in the MITL that limited the anode temperature rise due to ohmic heating. The results and conclusions from these experiments may have limited applicability to MITLs of high current density (>400 kA/cm) used in the convolute and load region of the Z which experience temperature increases of >400° C and generate ion emission from anode surfaces.

  16. 29 CFR 1926.1408 - Power line safety (up to 350 kV)-equipment operations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 8 2012-07-01 2012-07-01 false Power line safety (up to 350 kV)-equipment operations. 1926... Derricks in Construction § 1926.1408 Power line safety (up to 350 kV)—equipment operations. (a) Hazard... for use and conditions of use. Table A—Minimum Clearance Distances Voltage(nominal, kV,...

  17. 29 CFR 1926.1408 - Power line safety (up to 350 kV)-equipment operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety (up to 350 kV)-equipment operations. 1926... Derricks in Construction § 1926.1408 Power line safety (up to 350 kV)—equipment operations. (a) Hazard... for use and conditions of use. Table A—Minimum Clearance Distances Voltage(nominal, kV,...

  18. 29 CFR 1926.1408 - Power line safety (up to 350 kV)-equipment operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 8 2011-07-01 2011-07-01 false Power line safety (up to 350 kV)-equipment operations. 1926... Derricks in Construction § 1926.1408 Power line safety (up to 350 kV)—equipment operations. (a) Hazard... for use and conditions of use. Table A—Minimum Clearance Distances Voltage(nominal, kV,...

  19. 29 CFR 1926.1408 - Power line safety (up to 350 kV)-equipment operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety (up to 350 kV)-equipment operations. 1926... Derricks in Construction § 1926.1408 Power line safety (up to 350 kV)—equipment operations. (a) Hazard... for use and conditions of use. Table A—Minimum Clearance Distances Voltage(nominal, kV,...

  20. 78 FR 55249 - Grand Valley Rural Power Lines, Inc., Holy Cross Electric Association, Inc., Intermountain Rural...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-10

    ... Energy Regulatory Commission Grand Valley Rural Power Lines, Inc., Holy Cross Electric Association, Inc., Intermountain Rural Electric Association, Inc., Yampa Valley Electric Association, Inc. v. Public Service.... 824, 824(e) and 825(e) 2013, Grand Valley Rural Power Lines, Inc., Holy Cross Electric...

  1. Photopyroelectric ac calorimetric study of the nematic-smectic-A phase-transition line in binary liquid crystal mixtures with injected smectic-A phases.

    PubMed

    Caerels, J; Glorieux, C; Thoen, J

    2002-03-01

    Using a recently developed photopyroelectric ac calorimetric technique we investigate two binary liquid crystal mixtures with so-called injected smectic-A phases. Characteristic of these systems is the occurrence of nematic-to-smectic-A transition lines in the phase diagram of mixtures of pure compounds having only a nematic phase. The two binary systems are pentylcyanobiphenyl with either 4-n-propylcyclohexyl-carboxylate or 4-n-pentylphenyl 4(')-n-pentyloxybenzoate. Both these systems have domelike smectic-A ranges with narrow nematic ranges at the top. Near the top the N-SmA transitions are of first order and are crossing over to second order at a tricritical point on either side of the top with the increasing width of the nematic range. The obtained critical exponents are almost completely Fisher renormalized because of the strong concentration dependence of the nematic-to-smectic-A transition temperatures.

  2. Field and laboratory studies on the impact of two Bt rice lines expressing a fusion protein Cry1Ab/1Ac on aquatic organisms.

    PubMed

    Wang, Yongmo; Huang, Jiacheng; Hu, Huawei; Li, Jianhong; Liu, Biao; Zhang, Guoan

    2013-06-01

    Genetically modified (GM) rice expressing Bt toxins is at the edge of commercial release in China. However, little information is available concerning the impact of Bt rice on aquatic organisms which are abundant in paddy field. A two-year study was conducted to assess the effects of two GM rice lines expressing a fusion protein Cry1Ab/1Ac (Bt rice) on three groups of zooplankton, rotifers, cladocerans and copepods in field conditions. Multi-factor ANOVA revealed that the population densities of rotifers, cladocerans and copepods in paddy field varied significantly between years and rice developmental stages, but did not differ significantly between Bt and non-Bt rice treatments. In all the field investigations, only one significant difference was found on copepods in the tillering stage of 2009, but the difference was not related to the presence of the Cry toxin. Under open-air conditions, we simulated the farming practice of straw mulch, using Bt rice straw as a food source for the water flea Daphnia hyalina. After one and two months of culture, the density of D. hyalina did not differ between Bt rice treatments and non-Bt rice treatments. A laboratory experiment found that purified Bt toxins Cry1Ab and Cry1Ac had no toxic effect on D. hyalina even in the treatment in which the Bt toxin concentration was as high as 2500ng/ml. Those above results indicate that the two Bt rice lines have no negative effect on the three groups of zooplankton. However, further studies are needed to compare the effects of Bt rice and non-Bt rice on the paddy zooplankton community in the context of integrated pest management which includes the use of pesticides. PMID:23523003

  3. ELF field in the proximity of complex power line configuration measurement procedures.

    PubMed

    Benes, M; Comelli, M; Villalta, R

    2006-01-01

    The issue of how to measure magnetic induction fields generated by various power line configurations, when there are several power lines that run across the same exposure area, has become a matter of interest and study within the Regional Environment Protection Agency of Friuli Venezia Giulia. In classifying the various power line typologies the definition of double circuit line was given: in this instance the magnetic field is determined by knowing the electrical and geometric parameters of the line. In the case of independent lines instead, the field is undetermined. It is therefore pointed out how, in the latter case, extracting previsional information from a set of measurements of the magnetic field alone is impossible. Making measurements throughout the territory of service has in several cases offered the opportunity to define standard operational procedures. PMID:16410292

  4. Design of T-Split Power Divider Using Double Ended Spur-Line DMS

    NASA Astrophysics Data System (ADS)

    Moyra, Tamasi; Parui, Susanta Kumar; Das, Santanu

    2016-09-01

    Power dividers and power combiners are passive microwave components for power dividing and power combining. In this article one T-split equal power divider has been designed by using conventional 50 Ω microstrip line and double ended spur line renamed as defected microstrip structures (DMS). Introducing DMS provides one stop band characteristics, changes the effective inductance and capacitance of the line by increasing effective dielectric constant, reduces the phase velocity and supports slow-wave propagation. Thus, increases the effective line impedance of the microstrip line. Consequently, all passive and active components that are implemented using DMS have a miniaturized size compared to conventional components. In this paper one 3 dB or equal power divider has been designed at 1.6 GHz in the first step. Where, 100 Ω output line is implemented using double ended spur type DMS on conventional 50 Ω microstrip line. In the second step each output port power has been divided equally into 6 dB in the next level of the branch. Design of those dividers are very simple and have wide applications in microwave circuits and feeds of array antennas.

  5. Ag incorporated Mn3O4/AC nanocomposite based supercapacitor devices with high energy density and power density.

    PubMed

    Nagamuthu, S; Vijayakumar, S; Muralidharan, G

    2014-12-14

    Silver incorporated Mn3O4/amorphous carbon (AC) nanocomposites are synthesized by a green chemistry method. X-ray diffraction studies revealed the structural changes in Mn3O4/AC nanocomposites attributable to the addition of silver. Cyclic voltammetry, charge-discharge and ac-impedance studies indicated that the Ag-Mn3O4/AC-5 electrode was the most suitable candidate for supercapacitor applications. From the galvanostatic charge-discharge studies, a higher specific capacitance of 981 F g(-1) at a specific current of 1 A g(-1) was obtained. An Ag-Mn3O4/AC-symmetric supercapacitor consisting of an Ag-incorporated Mn3O4/AC composite as an anode as well as a cathode, and an asymmetric supercapacitor consisting of an Ag-incorporated Mn3O4/AC composite as a cathode and an activated carbon as an anode have been fabricated. The symmetric device exhibits a specific cell capacitance of 72 F g(-1) at a specific current of 1 A g(-1) whereas the asymmetric device delivers a specific cell capacitance of 180 F g(-1) at a high current rate of 10 A g(-1). The asymmetric supercapacitor device yields a high energy density of 81 W h kg(-1). This is higher than that of lead acid batteries and comparable with that of nickel hydride batteries.

  6. Electric Power Lines : Questions and Answers on Research into Health Effects.

    SciTech Connect

    United States. Bonneville Power Administration.

    1994-05-01

    Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the electric and magnetic fields (EMF) produced by power lines and other electrical devices cause health effects. The purpose of this booklet is to answer some common questions that the Bonneville Power Administration (BPA) receives about the possible effects of power lines on health. First, some basic electrical terms are defined, and electric and magnetic fields are debed. Next, answers are given to several questions about recent scientific studies. Some important information about electrical safety follows. We then describe how BPA is addressing public concerns about potential health effects of power lines. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this booklet.

  7. Gain Purchasing Power the Newfangled Way--On-Line.

    ERIC Educational Resources Information Center

    Milshtein, Amy

    1999-01-01

    Examines how San Diego State University uses computers to cut purchasing costs and boost efficiency and whether their solution can work for other business-to-business needs. How the school developed the totally self-sustaining, on-line and on-time purchasing system is discussed, including solutions to start-up problems. (GR)

  8. An algorithm for power line detection and warning based on a millimeter-wave radar video.

    PubMed

    Ma, Qirong; Goshi, Darren S; Shih, Yi-Chi; Sun, Ming-Ting

    2011-12-01

    Power-line-strike accident is a major safety threat for low-flying aircrafts such as helicopters, thus an automatic warning system to power lines is highly desirable. In this paper we propose an algorithm for detecting power lines from radar videos from an active millimeter-wave sensor. Hough Transform is employed to detect candidate lines. The major challenge is that the radar videos are very noisy due to ground return. The noise points could fall on the same line which results in signal peaks after Hough Transform similar to the actual cable lines. To differentiate the cable lines from the noise lines, we train a Support Vector Machine to perform the classification. We exploit the Bragg pattern, which is due to the diffraction of electromagnetic wave on the periodic surface of power lines. We propose a set of features to represent the Bragg pattern for the classifier. We also propose a slice-processing algorithm which supports parallel processing, and improves the detection of cables in a cluttered background. Lastly, an adaptive algorithm is proposed to integrate the detection results from individual frames into a reliable video detection decision, in which temporal correlation of the cable pattern across frames is used to make the detection more robust. Extensive experiments with real-world data validated the effectiveness of our cable detection algorithm.

  9. 77 FR 38793 - Grand Valley Rural Power Lines, Inc., Yampa Valley Electric Association, Inc., Intermountain...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-29

    ... Energy Regulatory Commission Grand Valley Rural Power Lines, Inc., Yampa Valley Electric Association, Inc., Intermountain Rural Electric Association, Tri-State Generation and Transmission Association, Inc. v. Public... Association, Inc., Intermountain Rural Electric Association, and Tri-State Generation and...

  10. Avian behavior and mortality at power lines in coastal South Carolina

    USGS Publications Warehouse

    Savereno, A.J.; Savereno, L.A.; Boettcher, R.; Haig, S.M.

    1996-01-01

    We compared avian behavior and mortality associated with two 115-kV transmission lines on the central South Carolina coast during 3,392 hours of observation from May 1991 through May 1994. One line was marked with 30-cm-diameter yellow aviation markers. The second line was unmarked, but was similar in most other aspects. We conducted ground searches (n = 445) beneath each line year-round to document avian mortality due to power-line collisions. At marked lines, birds that approached at line height changed behavior more at unmarked lines (P< 0.001), and fewer crossed between static and conductor wires. Collision rate was 53% lower at marked than unmarked lines. Among collisions at both sites, 82% of birds collided with static wires. Based on observed collisions and carcass recoveries, wading birds particularly appeared to be at risk. We concluded that aviation markers were effective at increasing line visibility and reducing collisions and recommend marking static wires of power lines in potentially sensitive areas.

  11. Electric Power Lines : Questions and Answers on Research into Health Effects.

    SciTech Connect

    United States. Bonneville Power Administration.

    1993-11-01

    Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the electric and magnetic fields (EMF) produced by power lines and other electrical devices cause health effects. The purpose of this pamphlet is to answer some common questions that the Bonneville Power Administration (BPA) receives about the possible effects of power lines on health. (BPA is the Pacific Northwest`s Federal electric power marketing agency.) First, some basic electrical terms are defined, and electric and magnetic fields are described. Next, answers are given to several questions about recent scientific studies. We then describe how BPA is addressing public concerns raised by these studies. Some important information about electrical safety follows. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this pamphlet.

  12. On-line diagnostic system for power generators

    SciTech Connect

    Skormin, V.A.; Goodenough, G.S.; Huber, R.K.

    1996-12-31

    A novel approach to diagnostics of a power generator is developed. It utilizes readily available data acquired by the existing computer-based monitoring/control system. Diagnostic procedures detect various trends in the generator data and interpret these trends in the generator data and interpret these trends as changes in the generator performance caused by incipient failures. Results of trend analyses, subjected to statistical validation, facilitate failure prediction and identification thus providing the justification for service when needed. The procedures are incorporated in a diagnostic system implemented in a PC interfaced with the existing VAX-based process monitoring and control system. The diagnostic system provides graphical display of the diagnostic messages.

  13. Circuit and Method for Communication Over DC Power Line

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J.; Prokop, Norman F.

    2007-01-01

    A circuit and method for transmitting and receiving on-off-keyed (OOK) signals with fractional signal-to-noise ratios uses available high-temperature silicon- on-insulator (SOI) components to move computational, sensing, and actuation abilities closer to high-temperature or high-ionizing radiation environments such as vehicle engine compartments, deep-hole drilling environments, industrial control and monitoring of processes like smelting, and operations near nuclear reactors and in space. This device allows for the networking of multiple, like nodes to each other and to a central processor. It can do this with nothing more than the already in-situ power wiring of the system. The device s microprocessor allows it to make intelligent decisions within the vehicle operational loop and to effect control outputs to its associated actuators. The figure illustrates how each node converts digital serial data to OOK 18-kHz in transmit mode and vice-versa in receive mode; though operations at lower frequencies or up to a megahertz are within reason using this method and these parts. This innovation s technique modulates a DC power bus with millivolt-level signals through a MOSFET (metal oxide semiconductor field effect transistor) and resistor by OOK. It receives and demodulates this signal from the DC power bus through capacitive coupling at high temperature and in high ionizing radiation environments. The demodulation of the OOK signal is accomplished by using an asynchronous quadrature detection technique realized by a quasi-discrete Fourier transform through use of the quadrature components (0 and 90 phases) of the carrier frequency as generated by the microcontroller and as a function of the selected crystal frequency driving its oscillator. The detected signal is rectified using an absolute-value circuit containing no diodes (diodes being non-operational at high temperatures), and only operational amplifiers. The absolute values of the two phases of the received signal

  14. Electrical power generating system. [for windpowered generation

    NASA Technical Reports Server (NTRS)

    Nola, F. J. (Inventor)

    1981-01-01

    An alternating current power generation system adopted to inject power in an already powered power line is discussed. The power generating system solves to adjustably coup an induction motor, as a generator, to an ac power line wherein the motor and power line are connected through a triac. The triac is regulated to normally turn on at a relatively late point in each half cycle of its operation, whereby at less than operating speed, and thus when the induction motor functions as a motor rather than as a generator, power consumption from the line is substantially reduced. The principal application will be for windmill powered generation.

  15. Modeling and optimization of the line-driver power consumption in xDSL systems

    NASA Astrophysics Data System (ADS)

    Wolkerstorfer, Martin; Trautmann, Steffen; Nordström, Tomas; Putra, Bakti D.

    2012-12-01

    Optimization of the power spectrum alleviates the crosstalk noise in digital subscriber lines (DSL) and thereby reduces their power consumption at present. In order to truly assess the DSL system power consumption, this article presents realistic line driver (LD) power consumption models. These are applicable to any DSL system and extend previous models by parameterizing various circuit-level non-idealities. Based on the model of a class-AB LD we analyze the multi-user power spectrum optimization problem and propose novel algorithms for its global or approximate solution. The thereby obtained simulation results support our claim that this problem can be simplified with negligible performance loss by neglecting the LD model. This motivates the usage of established spectral optimization algorithms, which are shown to significantly reduce the LD power consumption compared to static spectrum management.

  16. Do power lines and protected areas present a catch-22 situation for Cape vultures (Gyps coprotheres)?

    PubMed

    Phipps, W Louis; Wolter, Kerri; Michael, Michael D; MacTavish, Lynne M; Yarnell, Richard W

    2013-01-01

    Cape vulture Gyps coprotheres populations have declined across their range due to multiple anthropogenic threats. Their susceptibility to fatal collisions with the expanding power line network and the prevalence of carcasses contaminated with illegal poisons and other threats outside protected areas are thought to be the primary drivers of declines in southern Africa. We used GPS-GSM units to track the movements and delineate the home ranges of five adult (mean ±SD minimum convex polygon area = 121,655±90,845 km(2)) and four immature (mean ±SD minimum convex polygon area = 492,300±259,427 km(2)) Cape vultures to investigate the influence of power lines and their use of protected areas. The vultures travelled more than 1,000 km from the capture site and collectively entered five different countries in southern Africa. Their movement patterns and core foraging ranges were closely associated with the spatial distribution of transmission power lines and we present evidence that the construction of power lines has allowed the species to extend its range to areas previously devoid of suitable perches. The distribution of locations of known Cape vulture mortalities caused by interactions with power lines corresponded to the core ranges of the tracked vultures. Although some of the vultures regularly roosted at breeding colonies located inside protected areas the majority of foraging activity took place on unprotected farmland. Their ability to travel vast distances very quickly and the high proportion of time they spend in the vicinity of power lines and outside protected areas make Cape vultures especially vulnerable to negative interactions with the expanding power line network and the full range of threats across the region. Co-ordinated cross-border conservation strategies beyond the protected area network will therefore be necessary to ensure the future survival of threatened vultures in Africa. PMID:24137496

  17. Do power lines and protected areas present a catch-22 situation for Cape vultures (Gyps coprotheres)?

    PubMed

    Phipps, W Louis; Wolter, Kerri; Michael, Michael D; MacTavish, Lynne M; Yarnell, Richard W

    2013-01-01

    Cape vulture Gyps coprotheres populations have declined across their range due to multiple anthropogenic threats. Their susceptibility to fatal collisions with the expanding power line network and the prevalence of carcasses contaminated with illegal poisons and other threats outside protected areas are thought to be the primary drivers of declines in southern Africa. We used GPS-GSM units to track the movements and delineate the home ranges of five adult (mean ±SD minimum convex polygon area = 121,655±90,845 km(2)) and four immature (mean ±SD minimum convex polygon area = 492,300±259,427 km(2)) Cape vultures to investigate the influence of power lines and their use of protected areas. The vultures travelled more than 1,000 km from the capture site and collectively entered five different countries in southern Africa. Their movement patterns and core foraging ranges were closely associated with the spatial distribution of transmission power lines and we present evidence that the construction of power lines has allowed the species to extend its range to areas previously devoid of suitable perches. The distribution of locations of known Cape vulture mortalities caused by interactions with power lines corresponded to the core ranges of the tracked vultures. Although some of the vultures regularly roosted at breeding colonies located inside protected areas the majority of foraging activity took place on unprotected farmland. Their ability to travel vast distances very quickly and the high proportion of time they spend in the vicinity of power lines and outside protected areas make Cape vultures especially vulnerable to negative interactions with the expanding power line network and the full range of threats across the region. Co-ordinated cross-border conservation strategies beyond the protected area network will therefore be necessary to ensure the future survival of threatened vultures in Africa.

  18. Power lines, roads, and avian nest survival: effects on predator identity and predation intensity

    PubMed Central

    DeGregorio, Brett A; Weatherhead, Patrick J; Sperry, Jinelle H

    2014-01-01

    1 Anthropogenic alteration of landscapes can affect avian nest success by influencing the abundance, distribution, and behavior of predators. Understanding avian nest predation risk necessitates understanding how landscapes affect predator distribution and behavior. 2 From a sample of 463 nests of 17 songbird species, we evaluated how landscape features (distance to forest edge, unpaved roads, and power lines) influenced daily nest survival. We also used video cameras to identify nest predators at 137 nest predation events and evaluated how landscape features influenced predator identity. Finally, we determined the abundance and distribution of several of the principal predators using surveys and radiotelemetry. 3 Distance to power lines was the best predictor of predator identity: predation by brown-headed cowbirds (Molothrus ater), corvids (Corvus sp. and Cyanocitta cristata), racers (Coluber constrictor), and coachwhips (Masticophis flagellum) increased with proximity to power lines, whereas predation by rat snakes (Elaphe obsoleta) and raptors decreased. In some cases, predator density may reliably indicate nest predation risk because racers, corvids, and cowbirds frequently used power line right-of-ways. 4 Of five bird species with enough nests to analyze individually, daily nest survival of only indigo buntings (Passerina cyanea) decreased with proximity to power lines, despite predation by most predators at our site being positively associated with power lines. For all nesting species combined, distance to unpaved road was the model that most influenced daily nest survival. This pattern is likely a consequence of rat snakes, the locally dominant nest predator (28% of predation events), rarely using power lines and associated areas. Instead, rat snakes were frequently associated with road edges, indicating that not all edges are functionally similar. 5 Our results suggest that interactions between predators and landscape features are likely to be specific to

  19. Bird behavior and mortality in relation to power lines in prairie habitats

    USGS Publications Warehouse

    Faanes, C.A.

    1987-01-01

    Research was conducted to determine the magnitude of avian mortality caused by power transmission lines in prairie habitats during the two spring and two fall migration periods between July 1980 and May 1982. Searches for dead birds were made at least twice weekly during each migration period. Study sites were selected to include 'worst-case' situations involving potentially large concentrations of birds.In total, 633 dead birds were found beneath 9.6 km of power lines. About 81% of the birds were found during fall migration. Removal of birds by scavengers was of minor, although local, importance, and observer error in finding birds was greatest in areas of dense vegetation. Total kill was estimated at 1,332 birds.Data were gathered on more than 7,000 bird flights observed in the vicinity of the power lines. Sixty-eight percent of the birds did not respond to the presence of the power lines. Flaring and climbing over the conductor or overhead ground wire occurred in about 25% of the flights. One hundred nine birds in 82 flocks were observed to collide with a power line. Of these birds, 87% flared to climb over the power line before colliding. The overhead ground wire was responsible for most deaths, as 102 of 109 birds collided with it.Whereas none of the mortality observed was considered to be biologically significant at the particular sites examined, the cumulative effect of mortality sustained from collisions with power lines may be important, particularly to populations of rare or endangered birds.

  20. Do Power Lines and Protected Areas Present a Catch-22 Situation for Cape Vultures (Gyps coprotheres)?

    PubMed Central

    Phipps, W. Louis; Wolter, Kerri; Michael, Michael D.; MacTavish, Lynne M.; Yarnell, Richard W.

    2013-01-01

    Cape vulture Gyps coprotheres populations have declined across their range due to multiple anthropogenic threats. Their susceptibility to fatal collisions with the expanding power line network and the prevalence of carcasses contaminated with illegal poisons and other threats outside protected areas are thought to be the primary drivers of declines in southern Africa. We used GPS-GSM units to track the movements and delineate the home ranges of five adult (mean ±SD minimum convex polygon area  =  121,655±90,845 km2) and four immature (mean ±SD minimum convex polygon area  =  492,300±259,427 km2) Cape vultures to investigate the influence of power lines and their use of protected areas. The vultures travelled more than 1,000 km from the capture site and collectively entered five different countries in southern Africa. Their movement patterns and core foraging ranges were closely associated with the spatial distribution of transmission power lines and we present evidence that the construction of power lines has allowed the species to extend its range to areas previously devoid of suitable perches. The distribution of locations of known Cape vulture mortalities caused by interactions with power lines corresponded to the core ranges of the tracked vultures. Although some of the vultures regularly roosted at breeding colonies located inside protected areas the majority of foraging activity took place on unprotected farmland. Their ability to travel vast distances very quickly and the high proportion of time they spend in the vicinity of power lines and outside protected areas make Cape vultures especially vulnerable to negative interactions with the expanding power line network and the full range of threats across the region. Co-ordinated cross-border conservation strategies beyond the protected area network will therefore be necessary to ensure the future survival of threatened vultures in Africa. PMID:24137496

  1. Tevatron AC dipole system

    SciTech Connect

    Miyamoto, R.; Kopp, S.E.; Jansson, A.; Syphers, M.J.; /Fermilab

    2007-06-01

    The AC dipole is an oscillating dipole magnet which can induce large amplitude oscillations without the emittance growth and decoherence. These properties make it a good tool to measure optics of a hadron synchrotron. The vertical AC dipole for the Tevatron is powered by an inexpensive high power audio amplifier since its operating frequency is approximately 20 kHz. The magnet is incorporated into a parallel resonant system to maximize the current. The use of a vertical pinger magnet which has been installed in the Tevatron made the cost relatively inexpensive. Recently, the initial system was upgraded with a more powerful amplifier and oscillation amplitudes up to 2-3{sigma} were achieved with the 980 GeV proton beam. This paper discusses details of the Tevatron AC dipole system and also shows its test results.

  2. Predictive model of avian electrocution risk on overhead power lines.

    PubMed

    Dwyer, J F; Harness, R E; Donohue, K

    2014-02-01

    Electrocution on overhead power structures negatively affects avian populations in diverse ecosystems worldwide, contributes to the endangerment of raptor populations in Europe and Africa, and is a major driver of legal action against electric utilities in North America. We investigated factors associated with avian electrocutions so poles that are likely to electrocute a bird can be identified and retrofitted prior to causing avian mortality. We used historical data from southern California to identify patterns of avian electrocution by voltage, month, and year to identify species most often killed by electrocution in our study area and to develop a predictive model that compared poles where an avian electrocution was known to have occurred (electrocution poles) with poles where no known electrocution occurred (comparison poles). We chose variables that could be quantified by personnel with little training in ornithology or electric systems. Electrocutions were more common at distribution voltages (≤ 33 kV) and during breeding seasons and were more commonly reported after a retrofitting program began. Red-tailed Hawks (Buteo jamaicensis) (n = 265) and American Crows (Corvus brachyrhynchos) (n = 258) were the most commonly electrocuted species. In the predictive model, 4 of 14 candidate variables were required to distinguish electrocution poles from comparison poles: number of jumpers (short wires connecting energized equipment), number of primary conductors, presence of grounding, and presence of unforested unpaved areas as the dominant nearby land cover. When tested against a sample of poles not used to build the model, our model distributed poles relatively normally across electrocution-risk values and identified the average risk as higher for electrocution poles relative to comparison poles. Our model can be used to reduce avian electrocutions through proactive identification and targeting of high-risk poles for retrofitting. PMID:24033371

  3. Predictive model of avian electrocution risk on overhead power lines.

    PubMed

    Dwyer, J F; Harness, R E; Donohue, K

    2014-02-01

    Electrocution on overhead power structures negatively affects avian populations in diverse ecosystems worldwide, contributes to the endangerment of raptor populations in Europe and Africa, and is a major driver of legal action against electric utilities in North America. We investigated factors associated with avian electrocutions so poles that are likely to electrocute a bird can be identified and retrofitted prior to causing avian mortality. We used historical data from southern California to identify patterns of avian electrocution by voltage, month, and year to identify species most often killed by electrocution in our study area and to develop a predictive model that compared poles where an avian electrocution was known to have occurred (electrocution poles) with poles where no known electrocution occurred (comparison poles). We chose variables that could be quantified by personnel with little training in ornithology or electric systems. Electrocutions were more common at distribution voltages (≤ 33 kV) and during breeding seasons and were more commonly reported after a retrofitting program began. Red-tailed Hawks (Buteo jamaicensis) (n = 265) and American Crows (Corvus brachyrhynchos) (n = 258) were the most commonly electrocuted species. In the predictive model, 4 of 14 candidate variables were required to distinguish electrocution poles from comparison poles: number of jumpers (short wires connecting energized equipment), number of primary conductors, presence of grounding, and presence of unforested unpaved areas as the dominant nearby land cover. When tested against a sample of poles not used to build the model, our model distributed poles relatively normally across electrocution-risk values and identified the average risk as higher for electrocution poles relative to comparison poles. Our model can be used to reduce avian electrocutions through proactive identification and targeting of high-risk poles for retrofitting.

  4. Transmission line design for a power distribution system at 20 kHz for aircraft

    NASA Technical Reports Server (NTRS)

    Zelby, L. W.; Mathes, J. B.; Shawver, J. W.

    1986-01-01

    A low inductance, low characteristic impedance transmission line was designed for a 20 kHz power distribution system. Several different conductor configurations were considered: strip lines, interdigitated metal ribbons, and standard insulated wires in multiwire configurations (circular and rectangular cylindrical arrangements). The final design was a rectangular arrangement of multiple wires of the same gauge with alternating polarities from wire to wire. This offered the lowest inductance per unit length (on the order of several nanohenries/meter) and the lowest characteristic impedance (on the order of one Ohm). Standard multipin connectors with gold-plated elements were recommended with this transmission line, the junction boxes to be internally connected with flat metal ribbons for low inductance, and the line to be constructed in sections of suitable length. Computer programs for the calculation of inductance of multiwire lines and of capacitances of strip lines were developed.

  5. A Measurement and Power Line Communication System Design for Renewable Smart Grids

    NASA Astrophysics Data System (ADS)

    Kabalci, E.; Kabalci, Y.

    2013-10-01

    The data communication over the electric power lines can be managed easily and economically since the grid connections are already spread around all over the world. This paper investigates the applicability of Power Line Communication (PLC) in an energy generation system that is based on photovoltaic (PV) panels with the modeling study in Matlab/Simulink. The Simulink model covers the designed PV panels, boost converter with Perturb and Observe (P&O) control algorithm, full bridge inverter, and the binary phase shift keying (BPSK) modem that is utilized to transfer the measured data over the power lines. This study proposes a novel method to use the electrical power lines not only for carrying the line voltage but also to transmit the measurements of the renewable energy generation plants. Hence, it is aimed at minimizing the additional monitoring costs such as SCADA, Ethernet-based or GSM based systems by using the proposed technique. Although this study is performed with solar power plants, the proposed model can be applied to other renewable generation systems. Consequently, the usage of the proposed technique instead of SCADA or Ethernet-based systems eliminates additional monitoring costs.

  6. Childhood cancer and exposure to corona ions from power lines: an epidemiological test.

    PubMed

    Swanson, J; Bunch, K J; Vincent, T J; Murphy, M F G

    2014-12-01

    We previously reported an association between childhood leukaemia in Britain and proximity of the child's address at birth to high-voltage power lines that declines from the 1960s to the 2000s. We test here whether a 'corona-ion hypothesis' could explain these results. This hypothesis proposes that corona ions, atmospheric ions produced by power lines and blown away from them by the wind, increase the retention of airborne pollutants in the airways when breathed in and hence cause disease. We develop an improved model for calculating exposure to corona ions, using data on winds from meteorological stations and considering the whole length of power line within 600 m of each subject's address. Corona-ion exposure is highly correlated with proximity to power lines, and hence the results parallel the elevations in leukaemia risk seen with distance analyses. But our model explains the observed pattern of leukaemia rates around power lines less well than straightforward distance measurements, and ecological considerations also argue against the hypothesis. This does not disprove the corona-ion hypothesis as the explanation for our previous results, but nor does it provide support for it, or, by extension, any other hypothesis dependent on wind direction.

  7. Childhood cancer and exposure to corona ions from power lines: an epidemiological test.

    PubMed

    Swanson, J; Bunch, K J; Vincent, T J; Murphy, M F G

    2014-12-01

    We previously reported an association between childhood leukaemia in Britain and proximity of the child's address at birth to high-voltage power lines that declines from the 1960s to the 2000s. We test here whether a 'corona-ion hypothesis' could explain these results. This hypothesis proposes that corona ions, atmospheric ions produced by power lines and blown away from them by the wind, increase the retention of airborne pollutants in the airways when breathed in and hence cause disease. We develop an improved model for calculating exposure to corona ions, using data on winds from meteorological stations and considering the whole length of power line within 600 m of each subject's address. Corona-ion exposure is highly correlated with proximity to power lines, and hence the results parallel the elevations in leukaemia risk seen with distance analyses. But our model explains the observed pattern of leukaemia rates around power lines less well than straightforward distance measurements, and ecological considerations also argue against the hypothesis. This does not disprove the corona-ion hypothesis as the explanation for our previous results, but nor does it provide support for it, or, by extension, any other hypothesis dependent on wind direction. PMID:25356811

  8. Research of on-line monitoring method for insulation condition of power transformer bushing

    NASA Astrophysics Data System (ADS)

    Xia, Jiuyun; Qian, Zheng; Yu, Hao; Yao, Junda

    2016-01-01

    The power transformer is the key equipment of the power system; its insulation condition will directly influence the security and reliability of the power system. Thus, the on-line monitoring of power transformer is urgently required in order to guarantee the normal operation of the power system. Moreover, the dielectric loss factor is a significant parameter reflecting the condition of transformer bushing, so the on-line measurement of dielectric loss factor is really important. In this paper, the phase-to-phase comparison method is selected as the on-line monitoring method based on the overall analysis and discussion of the existing on-line monitoring methods. At first, the harmonic analysis method is utilized to calculate the dielectric loss of each phase of the three-phase transformer bushing, and then the differences of dielectric loss between every two phases are calculated and analyzed. So the insulation condition of each bushing could be achieved based on the careful analysis of different phase-to-phase dielectric loss. The simulation results of phase-to-phase comparison method are carried out in this paper, and the validity is verified. At last, this method is utilized in an actual equipment of on-line monitoring.

  9. Electric Power Lines : Questions and Answers on Research into Health Effects.

    SciTech Connect

    United States. Bonneville Power Administration.

    1995-06-01

    Most people know that electric power lines, like the wiring in our homes, can cause serious electric shocks if we`re not careful. Many people also want to know whether the EMF (electric and magnetic fields) produced by power lines and other electrical devices affect our health. Although no adverse health effects of electric power EMF have been confirmed, there is continued scientific uncertainty about this issue. Research on EMF is ongoing throughout the world. The purpose of this booklet is to answer some common questions that the BPA (Bonneville Power Administration) receives about the possible effects of power lines on health. First, some basic electrical terms are defined, and electric and magnetic fields are debed. Next, answers are given to several questions about recent scientific studies. Some important information about electrical safety follows. We then describe how BPA is addressing public concerns about potential health effects of power lines. The last section tells you how to obtain more detailed information about the health and safety issues summarized in this booklet.

  10. Observer-based higher order sliding mode control of power factor in three-phase AC/DC converter for hybrid electric vehicle applications

    NASA Astrophysics Data System (ADS)

    Liu, Jianxing; Laghrouche, Salah; Wack, Maxime

    2014-06-01

    In this paper, a full-bridge boost power converter topology is studied for power factor control, using output higher order sliding mode control. The AC/DC converters are used for charging the battery and super-capacitor in hybrid electric vehicles from the utility. The proposed control forces the input currents to track the desired values, which can control the output voltage while keeping the power factor close to one. Super-twisting sliding mode observer is employed to estimate the input currents and load resistance only from the measurement of output voltage. Lyapunov analysis shows the asymptotic convergence of the closed-loop system to zero. Multi-rate simulation illustrates the effectiveness and robustness of the proposed controller in the presence of measurement noise.

  11. Nonlinear femtosecond pump-probe spectroscopy using a power-encoded soliton delay line.

    PubMed

    Saint-Jalm, Sarah; Andresen, Esben Ravn; Bendahmane, Abdelkrim; Kudlinski, Alexandre; Rigneault, Hervé

    2016-01-01

    We show femtosecond time-resolved nonlinear pump-probe spectroscopy using a fiber soliton as the probe pulse. Furthermore, we exploit soliton dynamics to record an entire transient trace with a power-encoded delay sweep. The power-encoded delay line takes advantage of the dependency of the soliton trajectory in the (λ,z) space upon input power; the difference in accumulated group delay between trajectories converts a fast power sweep into a fast delay sweep. We demonstrate the concept by performing transient absorption spectroscopy in a test sample and validate it against a conventional pump-probe setup.

  12. Increased Ac excision (iae): Arabidopsis thaliana mutations affecting Ac transposition.

    PubMed

    Jarvis, P; Belzile, F; Page, T; Dean, C

    1997-05-01

    The maize transposable element Ac is highly active in the heterologous hosts tobacco and tomato, but shows very much reduced levels of activity in Arabidopsis. A mutagenesis experiment was undertaken with the aim of identifying Arabidopsis host factors responsible for the observed low levels of Ac activity. Seed from a line carrying a single copy of the Ac element inserted into the streptomycin phosphotransferase (SPT) reporter fusion, and which displayed typically low levels of Ac activity, were mutagenized using gamma rays. Nineteen mutants displaying high levels of somatic Ac activity, as judged by their highly variegated phenotypes, were isolated after screening the M2 generation on streptomycin-containing medium. The mutations fall into two complementation groups, iae1 and iae2, are unlinked to the SPT::Ac locus and segregate in a Mendelian fashion. The iae1 mutation is recessive and the iae2 mutation is semi-dominant. The iae1 and iae2 mutants show 550- and 70-fold increases, respectively, in the average number of Ac excision sectors per cotyledon. The IAE1 locus maps to chromosome 2, whereas the SPT::Ac reporter maps to chromosome 3. A molecular study of Ac activity in the iae1 mutant confirmed the very high levels of Ac excision predicted using the phenotypic assay, but revealed only low levels of Ac re-insertion. Analyses of germinal transposition in the iae1 mutant demonstrated an average germinal excision frequency of 3% and a frequency of independent Ac re-insertions following germinal excision of 22%. The iae mutants represents a possible means of improving the efficiency of Ac/Ds transposon tagging systems in Arabidopsis, and will enable the dissection of host involvement in Ac transposition and the mechanisms employed for controlling transposable element activity.

  13. Refining Estimates of Bird Collision and Electrocution Mortality at Power Lines in the United States

    PubMed Central

    Loss, Scott R.; Will, Tom; Marra, Peter P.

    2014-01-01

    Collisions and electrocutions at power lines are thought to kill large numbers of birds in the United States annually. However, existing estimates of mortality are either speculative (for electrocution) or based on extrapolation of results from one study to all U.S. power lines (for collision). Because national-scale estimates of mortality and comparisons among threats are likely to be used for prioritizing policy and management strategies and for identifying major research needs, these estimates should be based on systematic and transparent assessment of rigorously collected data. We conducted a quantitative review that incorporated data from 14 studies meeting our inclusion criteria to estimate that between 12 and 64 million birds are killed each year at U.S. power lines, with between 8 and 57 million birds killed by collision and between 0.9 and 11.6 million birds killed by electrocution. Sensitivity analyses indicate that the majority of uncertainty in our estimates arises from variation in mortality rates across studies; this variation is due in part to the small sample of rigorously conducted studies that can be used to estimate mortality. Little information is available to quantify species-specific vulnerability to mortality at power lines; the available literature over-represents particular bird groups and habitats, and most studies only sample and present data for one or a few species. Furthermore, additional research is needed to clarify whether, to what degree, and in what regions populations of different bird species are affected by power line-related mortality. Nonetheless, our data-driven analysis suggests that the amount of bird mortality at U.S. power lines is substantial and that conservation management and policy is necessary to reduce this mortality. PMID:24991997

  14. Refining estimates of bird collision and electrocution mortality at power lines in the United States.

    PubMed

    Loss, Scott R; Will, Tom; Marra, Peter P

    2014-01-01

    Collisions and electrocutions at power lines are thought to kill large numbers of birds in the United States annually. However, existing estimates of mortality are either speculative (for electrocution) or based on extrapolation of results from one study to all U.S. power lines (for collision). Because national-scale estimates of mortality and comparisons among threats are likely to be used for prioritizing policy and management strategies and for identifying major research needs, these estimates should be based on systematic and transparent assessment of rigorously collected data. We conducted a quantitative review that incorporated data from 14 studies meeting our inclusion criteria to estimate that between 12 and 64 million birds are killed each year at U.S. power lines, with between 8 and 57 million birds killed by collision and between 0.9 and 11.6 million birds killed by electrocution. Sensitivity analyses indicate that the majority of uncertainty in our estimates arises from variation in mortality rates across studies; this variation is due in part to the small sample of rigorously conducted studies that can be used to estimate mortality. Little information is available to quantify species-specific vulnerability to mortality at power lines; the available literature over-represents particular bird groups and habitats, and most studies only sample and present data for one or a few species. Furthermore, additional research is needed to clarify whether, to what degree, and in what regions populations of different bird species are affected by power line-related mortality. Nonetheless, our data-driven analysis suggests that the amount of bird mortality at U.S. power lines is substantial and that conservation management and policy is necessary to reduce this mortality.

  15. Re-creation of aerosol charge state found near HV power lines using a high voltage corona charger

    NASA Astrophysics Data System (ADS)

    Matthews, J. C.; Wright, M. D.; Biddiscombe, M. F.; Underwood, R.; Usmani, O. S.; Shallcross, D. E.; Henshaw, D. L.

    2015-10-01

    Corona ionisation from AC HV power lines (HVPL) can release ions into the environment, which have the potential to electrically charge pollutant aerosol in the atmosphere. It has been hypothesised that these charged particles have an enhanced probability of being deposited in human airways upon inhalation due to electrostatic attraction by image charge within the lung, with implications for human health. Carbonaceous aerosol particles from a Technegas generator were artificially charge-enhanced using a corona charger. Once generated, particles were passed through the charger, which was either on or off, and stored in a 15 litre conducting bag for ∼20 minutes to observe size and charge distribution changes over time. Charge states were estimated using two Sequential Mobility Particle Sizers measuring the size and mobility distributions. Charge-neutral particles were measured 7 times and positive particles 9 times, the average charge-neutral value of x was 1.00 (sd = 0.06) while the average positive value was 4.60 (0.72). The system will be used to generate positive or charge neutral particles for delivery to human volunteers in an inhalation study to assess the impact of charge on ultrafine (size < 100 nm) particle deposition.

  16. Comparison of charged nanoparticle concentrations near busy roads and overhead high-voltage power lines.

    PubMed

    Jayaratne, E R; Ling, X; Morawska, L

    2015-09-01

    Overhead high-voltage power lines are known sources of corona ions. These ions rapidly attach to aerosols to form charged particles in the environment. Although the effect of ions and charged particles on human health is largely unknown, much attention has focused on the increasing exposure as a result of the expanding power network in urban residential areas. However, it is not widely known that a large number of charged particles in urban environments originate from motor vehicle emissions. In this study, for the first time, we compare the concentrations of charged nanoparticles near busy roads and overhead power lines. We show that large concentrations of both positive and negative charged nanoparticles are present near busy roadways and that these concentrations commonly exceed those under high-voltage power lines. We estimate that the concentration of charged nanoparticles found near two freeways carrying around 120 vehicles per minute exceeded the corresponding maximum concentrations under two corona-emitting overhead power lines by as much as a factor of 5. The difference was most pronounced when a significant fraction of traffic consisted of heavy-duty diesel vehicles which typically have high particle and charge emission rates.

  17. Comparison of charged nanoparticle concentrations near busy roads and overhead high-voltage power lines.

    PubMed

    Jayaratne, E R; Ling, X; Morawska, L

    2015-09-01

    Overhead high-voltage power lines are known sources of corona ions. These ions rapidly attach to aerosols to form charged particles in the environment. Although the effect of ions and charged particles on human health is largely unknown, much attention has focused on the increasing exposure as a result of the expanding power network in urban residential areas. However, it is not widely known that a large number of charged particles in urban environments originate from motor vehicle emissions. In this study, for the first time, we compare the concentrations of charged nanoparticles near busy roads and overhead power lines. We show that large concentrations of both positive and negative charged nanoparticles are present near busy roadways and that these concentrations commonly exceed those under high-voltage power lines. We estimate that the concentration of charged nanoparticles found near two freeways carrying around 120 vehicles per minute exceeded the corresponding maximum concentrations under two corona-emitting overhead power lines by as much as a factor of 5. The difference was most pronounced when a significant fraction of traffic consisted of heavy-duty diesel vehicles which typically have high particle and charge emission rates. PMID:25917858

  18. Theory and simulation of high-power microwave generation in a magnetically insulated transmission line oscillator

    NASA Astrophysics Data System (ADS)

    Lemke, Raymond W.; Clark, Collins M.

    1987-10-01

    The magnetically insulated transmission line (MITE-LINE) oscillator is an electron beam diode comprised of a field emitting cathode and a corrugated anode. The device is similar to a linear magnetron except that the insulating magnetic field is self-generated. The self-insulating property makes this device a robust high-power microwave tube. Using the thin-beam approximation a dispersion relation for a cylindrical MITE-LINE oscillator is derived. The dispersion relation is used to predict frequency and growth rate of the microwave generating instability. Analytical results are compared with CCUBE particle simulations.

  19. Safety against lightning for linemen working on de-energized power lines

    SciTech Connect

    Mousa, A.M.; Srivastava, K.D.

    1986-01-01

    Where the risk of accidental power-frequency energization is concerned, the safety ground has a short-circuit discharge duty determined by the configuration and parameters of the power system. Safety is thus assured by selecting a safety ground having a short-circuit safety rating which matches the duty imposed by the power system. Up to now, a similar matching for lightning currents has not been possible. This paper addresses this problem by: 1. Determining the lightning current rating of typical safety grounds. 2. Calculating the lightning current discharge duty of safety grounds in terms of the insulatuon level of the line and the distance from the location of the thunderstorm. The analysis shows that special precautions are needed when working on power lines of voltage classes above 360 kV.

  20. The Effect Analysis of Strain Rate on Power Transmission Tower-Line System under Seismic Excitation

    PubMed Central

    Wang, Wenming

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system. PMID:25105157

  1. The effect analysis of strain rate on power transmission tower-line system under seismic excitation.

    PubMed

    Tian, Li; Wang, Wenming; Qian, Hui

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system. PMID:25105157

  2. The effect analysis of strain rate on power transmission tower-line system under seismic excitation.

    PubMed

    Tian, Li; Wang, Wenming; Qian, Hui

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system.

  3. Bias-field controlled phasing and power combination of gyromagnetic nonlinear transmission lines

    SciTech Connect

    Reale, D. V. Bragg, J.-W. B.; Gonsalves, N. R.; Johnson, J. M.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J.

    2014-05-15

    Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance.

  4. Evaluation of line focus solar central power systems. Volume II. Systems evaluation

    SciTech Connect

    Not Available

    1980-03-15

    An evaluation was completed to ascertain the applicability of line focus technologies to electrical power applications and to compare their performance and cost potential with point focus central receiver power systems. It was concluded that although the high temperature line focus (SRI) and fixed mirror line focus (GA) concepts duplicate the heat source characteristics and power conversion technology of the central receiver concepts these configurations do not offer a sufficient improvement in cost to warrant full scale development. The systems are, however, less complex than their point focus counterpart and should the central receiver system development falter they provide reasonable technology alternatives. The parabolic trough concept (BDM) was found to provide a low temperature technology alternative to the central receiver concept with promising performance and cost potential. Its continued development is recommended, with special emphasis on lower temperature (< 700/sup 0/F) applications. Finally, a variety of new promising line focus power system configurations were identified for a range of utility and industrial applications and recommendations were made on their implementation. This volume contains the detailed report. (WHK)

  5. 76 FR 76044 - Safety Zone; Power Line Replacement, West Bay, Panama City, FL

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-06

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; Power Line Replacement, West Bay, Panama... establishing a temporary safety zone for a portion of West Bay Creek and West Bay, to include all waters between the Highway 79 Fixed Bridge and the mouth of West Bay Creek out to buoy markers 27 and 28 of...

  6. 30 CFR 56.12071 - Movement or operation of equipment near high-voltage power lines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... NONMETAL MINES Electricity § 56.12071 Movement or operation of equipment near high-voltage power lines. When equipment must be moved or operated near energized high-voltage powerlines (other than trolley... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Movement or operation of equipment near...

  7. Power Line Technician. Second Edition. Module G. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This module is the seventh in a series that is designed to help students achieve greater professional and personal success as power line technicians. Each module represents one or more complete units of instruction with components organized into one instructor and one student "package": the instructor's manual and the student workbook. The…

  8. 30 CFR 56.12071 - Movement or operation of equipment near high-voltage power lines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... NONMETAL MINES Electricity § 56.12071 Movement or operation of equipment near high-voltage power lines. When equipment must be moved or operated near energized high-voltage powerlines (other than trolley... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Movement or operation of equipment near...

  9. 30 CFR 56.12071 - Movement or operation of equipment near high-voltage power lines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... NONMETAL MINES Electricity § 56.12071 Movement or operation of equipment near high-voltage power lines. When equipment must be moved or operated near energized high-voltage powerlines (other than trolley... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Movement or operation of equipment near...

  10. 30 CFR 56.12071 - Movement or operation of equipment near high-voltage power lines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Movement or operation of equipment near high-voltage power lines. 56.12071 Section 56.12071 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity §...

  11. 30 CFR 56.12071 - Movement or operation of equipment near high-voltage power lines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... NONMETAL MINES Electricity § 56.12071 Movement or operation of equipment near high-voltage power lines. When equipment must be moved or operated near energized high-voltage powerlines (other than trolley... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Movement or operation of equipment near...

  12. Power line characterization from an airborne data collection with a millimeter wave radar

    NASA Astrophysics Data System (ADS)

    Goshi, Darren S.; Bui, Long Q.

    2014-05-01

    Enhancing the operational safety of small, maneuverable rotorcraft has been a critical consideration in the development of next generation situational awareness sensor suites. From landing assistance to target detection and obstacle avoidance, millimeter wave radars have become the leading candidate for such solutions due to their ability to operate in degraded visual environments, whether it is weather, induced debris, or night conditions that must be dealt with. Power lines pose arguably the largest safety risk for helicopter operation due to their difficulty in detection and proper identification to support avoidance maneuvering, where even under perfect conditions they can be nearly invisible to the naked eye. The backscatter phenomenology from braided power lines has been well-studied and formulated in previous literature, albeit mainly in controlled laboratory settings or limited field trials. Subsequently, the ability to simply detect power lines at operational distances up to around 2 km has been demonstrated. In this work, an analysis is performed on the measureable characteristics of power lines captured in a representative operational environment for helicopters. The test location included a diverse set of power line configurations with surrounding ground and tower clutter, representing a realistic scenario. A radiometrically calibrated w-band real-beam FMCW sensor allows the study and estimation of target RCS, as well as evaluation against the developed theory. All analysis is performed on dynamically captured data from a helicopter, where platform dynamics and system stability also play a significant role in a processed result. Results from this work will aid the effective development of next generation situational awareness systems.

  13. Voltages induced on a power distribution line by overhead cloud lightning

    NASA Technical Reports Server (NTRS)

    Yacoub, Ziad; Rubinstein, Marcos; Uman, Martin A.; Thomson, Ewen M.; Medelius, Pedro J.

    1991-01-01

    Voltages induced by overhead cloud lightning on a 448 m open circuited power distribution line and the corresponding north-south component of the lightning magnetic field were simultaneously measured at the NASA Kennedy Space Center during the summer of 1986. The incident electric field was calculated from the measured magnetic field. The electric field was then used as an input to the computer program, EMPLIN, that calculated the voltages at the two ends of the power line. EMPLIN models the frequency domain field/power coupling theory found, for example, in Ianoz et al. The direction of the source, which is also one of the inputs to EMPLIN, was crudely determined from a three station time delay technique. The authors found reasonably good agreement between calculated and measured waveforms.

  14. A Bayesian Prediction Framework of Weather Based Power Line Damages in the Northeast

    NASA Astrophysics Data System (ADS)

    frediani, M.; Anagnostou, E. N.; Wanik, D.; Scerbo, D.

    2012-12-01

    This study aims to evaluate the predictability of damages to overhead power distribution lines from severe weather events in the New England area. During storms, trees and branches can come down and interact with power lines that results in significant interruptions to electricity distribution, causing major interruptions to residents and monetary losses to the utility company. In Connecticut, a densely forested state, severe winds and precipitation (in the form of rain and snow) from storms are key weather factors that challenge the power grid infrastructure vulnerability. Evaluating the local predictability of these impacts may aid local power utilities with crew allocation and preparedness during an event. A probabilistic approach to damage prediction caused by trees subjected to severe weather is being investigated in the region. This study specifically, explores the feasibility of applying Bayesian inversion technique to weather parameters by developing a damage decision tree composed of various meteorological and static parameters, like wind gust, precipitation (rain and snow accumulation and rates), high canopy forest density and tree trimming history for the power distribution lines. The resulting decision tree can be used as a Bayesian inversion database to predict the probability distribution of damages given a storm forecast. The Bayesian database is based on a historical data source provided by The Connecticut Light & Power Company (Connecticut's primary power utility) containing geographical information of trouble spots caused by thunderstorm and winter/snow-storm events; power line specifications and trimming history; and high-resolution model analysis of those storms. The analysis is based on a 2-sqkm model grid cropped over the state of Connecticut comprising a database of 3,307 pixels per storm. Each storm pixel is flagged to contain power line damages or no-damages. A total of 50 storm simulations is used to build the database. Pairs of

  15. 10 CFR Appendix Z to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of External Power Supplies

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... power supply that is designed to convert line voltage AC input into more than one simultaneous lower-voltage output. j. Nameplate input frequency means the AC input frequency of the power supply as specified on the manufacturer's label on the power supply housing. k. Nameplate input voltage means the...

  16. ac bidirectional motor controller

    NASA Technical Reports Server (NTRS)

    Schreiner, K.

    1988-01-01

    Test data are presented and the design of a high-efficiency motor/generator controller at NASA-Lewis for use with the Space Station power system testbed is described. The bidirectional motor driver is a 20 kHz to variable frequency three-phase ac converter that operates from the high-frequency ac bus being designed for the Space Station. A zero-voltage-switching pulse-density-modulation technique is used in the converter to shape the low-frequency output waveform.

  17. Effects of water management practices on residue decomposition and degradation of Cry1Ac protein from crop-wild Bt rice hybrids and parental lines during winter fallow season.

    PubMed

    Xiao, Manqiu; Dong, Shanshan; Li, Zhaolei; Tang, Xu; Chen, Yi; Yang, Shengmao; Wu, Chunyan; Ouyang, Dongxin; Fang, Changming; Song, Zhiping

    2015-12-01

    Rice is the staple diet of over half of the world's population and Bacillus thuringiensis (Bt) rice expressing insecticidal Cry proteins is ready for deployment. An assessment of the potential impact of Bt rice on the soil ecosystem under varied field management practices is urgently required. We used litter bags to assess the residue (leaves, stems and roots) decomposition dynamics of two transgenic rice lines (Kefeng6 and Kefeng8) containing stacked genes from Bt and sck (a modified CpTI gene encoding a cowpea trypsin inhibitor) (Bt/CpTI), a non-transgenic rice near-isoline (Minghui86), wild rice (Oryza rufipogon) and crop-wild Bt rice hybrid under contrasting conditions (drainage or continuous flooding) in the field. No significant difference was detected in the remaining mass, total C and total N among cultivars under aerobic conditions, whereas significant differences in the remaining mass and total C were detected between Kefeng6 and Kefeng8 and Minghui86 under the flooded condition. A higher decomposition rate constant (km) was measured under the flooded condition compared with the aerobic condition for leaf residues, whereas the reverse was observed for root residues. The enzyme-linked immunosorbent assay (ELISA), which was used to monitor the changes in the Cry1Ac protein in Bt rice residues, indicated that (1) the degradation of the Cry1Ac protein under both conditions best fit first-order kinetics, and the predicted DT50 (50% degradation time) of the Cry1Ac protein ranged from 3.6 to 32.5 days; (2) the Cry1Ac protein in the residue degraded relatively faster under aerobic conditions; and (3) by the end of the study (~154 days), the protein was present at a low concentration in the remaining residues under both conditions. The degradation rate constant was negatively correlated with the initial carbon content and positively correlated with the initial Cry1Ac protein concentration, but it was only correlated with the mass decomposition rate constants under

  18. Multivariable time series prediction for the icing process on overhead power transmission line.

    PubMed

    Li, Peng; Zhao, Na; Zhou, Donghua; Cao, Min; Li, Jingjie; Shi, Xinling

    2014-01-01

    The design of monitoring and predictive alarm systems is necessary for successful overhead power transmission line icing. Given the characteristics of complexity, nonlinearity, and fitfulness in the line icing process, a model based on a multivariable time series is presented here to predict the icing load of a transmission line. In this model, the time effects of micrometeorology parameters for the icing process have been analyzed. The phase-space reconstruction theory and machine learning method were then applied to establish the prediction model, which fully utilized the history of multivariable time series data in local monitoring systems to represent the mapping relationship between icing load and micrometeorology factors. Relevant to the characteristic of fitfulness in line icing, the simulations were carried out during the same icing process or different process to test the model's prediction precision and robustness. According to the simulation results for the Tao-Luo-Xiong Transmission Line, this model demonstrates a good accuracy of prediction in different process, if the prediction length is less than two hours, and would be helpful for power grid departments when deciding to take action in advance to address potential icing disasters. PMID:25136653

  19. INVESTIGATION OF A DYNAMIC POWER LINE RATING CONCEPT FOR IMPROVED WIND ENERGY INTEGRATION OVER COMPLEX TERRAIN

    SciTech Connect

    Jake P. Gentle; Kurt S Myers; Tyler B Phillips; Inanc Senocak; Phil Anderson

    2014-08-01

    Dynamic Line Rating (DLR) is a smart grid technology that allows the rating of power line to be based on real-time conductor temperature dependent on local weather conditions. In current practice overhead power lines are generally given a conservative rating based on worst case weather conditions. Using historical weather data collected over a test bed area, we demonstrate there is often additional transmission capacity not being utilized with the current static rating practice. We investigate a new dynamic line rating methodology using computational fluid dynamics (CFD) to determine wind conditions along transmission lines at dense intervals. Simulated results are used to determine conductor temperature by calculating the transient thermal response of the conductor under variable environmental conditions. In calculating the conductor temperature, we use both a calculation with steady-state assumption and a transient calculation. Under low wind conditions, steady-state assumption predicts higher conductor temperatures that could lead to curtailments, whereas transient calculations produce conductor temperatures that are significantly lower, implying the availability of additional transmission capacity.

  20. Multivariable Time Series Prediction for the Icing Process on Overhead Power Transmission Line

    PubMed Central

    Li, Peng; Zhao, Na; Zhou, Donghua; Cao, Min; Li, Jingjie; Shi, Xinling

    2014-01-01

    The design of monitoring and predictive alarm systems is necessary for successful overhead power transmission line icing. Given the characteristics of complexity, nonlinearity, and fitfulness in the line icing process, a model based on a multivariable time series is presented here to predict the icing load of a transmission line. In this model, the time effects of micrometeorology parameters for the icing process have been analyzed. The phase-space reconstruction theory and machine learning method were then applied to establish the prediction model, which fully utilized the history of multivariable time series data in local monitoring systems to represent the mapping relationship between icing load and micrometeorology factors. Relevant to the characteristic of fitfulness in line icing, the simulations were carried out during the same icing process or different process to test the model's prediction precision and robustness. According to the simulation results for the Tao-Luo-Xiong Transmission Line, this model demonstrates a good accuracy of prediction in different process, if the prediction length is less than two hours, and would be helpful for power grid departments when deciding to take action in advance to address potential icing disasters. PMID:25136653

  1. Research of on-line monitoring equipment for power capacitor based on wireless sensor network

    NASA Astrophysics Data System (ADS)

    Yu, Hao; Qian, Zheng; Yao, Junda; Xia, Jiuyun

    2016-01-01

    As the main electrical component for the reactive power compensation, the power capacitors are widely applied in many fields. And since the insulation condition of power capacitor could be identified accurately by using the on-line monitoring system, it attracts more and more attentions in recent years. In this paper, a novel on-line monitoring equipment for power capacitor based on wireless sensor network is presented. The operation data which includes the current and voltage of every capacitor is collected at first, and then the FFT is utilized to calculate the amplitude and phase of every signal, thus the insulation condition and the fault symptom could all be diagnosed accurately by analyzing the FFT results. In order to realize the effective isolation and the reliable communication between the sensing part and the merging unit, the wireless sensor network is adopted. The high reliability and transmission rate could be realized by using 2.4GHz UHF and 5GHz ISM radio bands. Thus the on-line monitoring system could be manufactured, and the lab test is carried at last. The testing results illustrate that this system could satisfy the requirement of on-site real-time measurement.

  2. A high fraction of double-peaked narrow emission lines in powerful active galactic nuclei

    NASA Astrophysics Data System (ADS)

    Lyu, Yang; Liu, Xin

    2016-11-01

    1 per cent of redshift z ˜ 0.1 active galactic nuclei (AGNs) show velocity splitting of a few hundred km s-1 in the narrow emission lines in spatially integrated spectra. Such line profiles have been found to arise from the bulk motion of ionized gas clouds associated with galactic-scale outflows, merging pairs of galaxies each harbouring a supermassive black hole (SMBH), and/or galactic-scale disc rotation. It remains unclear, however, how the frequency of narrow-line velocity splitting may depend on AGN luminosity. Here we study the correlation between the fraction of Type 2 AGNs with double-peaked narrow emission lines and AGN luminosity as indicated by [O III] λ5007 emission-line luminosity L_[O III]. We combine the sample of Liu et al. at z ˜ 0.1 with a new sample of 178 Type 2 AGNs with double-peaked [O III] emission lines at z ˜ 0.5. We select the new sample from a parent sample of 2089 Type 2 AGNs from the SDSS-III/Baryon Oscillation Spectroscopic Survey. We find a statistically significant (˜4.2σ) correlation between L_[O III] and the fraction of objects that exhibit double-peaked narrow emission lines among all Type 2 AGNs, corrected for selection bias and incompleteness due to [O III] line width, equivalent width, splitting velocity, and/or equivalent width ratio between the two velocity components. Our result suggests that galactic-scale outflows and/or merging pairs of SMBHs are more prevalent in more powerful AGNs, although spatially resolved follow-up observations are needed to resolve the origin(s) for the narrow-line velocity splitting for individual AGNs.

  3. Parametric analysis of hollow conductor parallel and coaxial transmission lines for high frequency space power distribution

    NASA Technical Reports Server (NTRS)

    Jeffries, K. S.; Renz, D. D.

    1984-01-01

    A parametric analysis was performed of transmission cables for transmitting electrical power at high voltage (up to 1000 V) and high frequency (10 to 30 kHz) for high power (100 kW or more) space missions. Large diameter (5 to 30 mm) hollow conductors were considered in closely spaced coaxial configurations and in parallel lines. Formulas were derived to calculate inductance and resistance for these conductors. Curves of cable conductance, mass, inductance, capacitance, resistance, power loss, and temperature were plotted for various conductor diameters, conductor thickness, and alternating current frequencies. An example 5 mm diameter coaxial cable with 0.5 mm conductor thickness was calculated to transmit 100 kW at 1000 Vac, 50 m with a power loss of 1900 W, an inductance of 1.45 micron and a capacitance of 0.07 micron-F. The computer programs written for this analysis are listed in the appendix.

  4. K-Band Power Enbedded Transmission Line (ETL) MMIC Amplifiers for Satellite Communication Applications

    NASA Technical Reports Server (NTRS)

    Tserng, Hua-Quen; Ketterson, Andrew; Saunier, Paul; McCarty, Larry; Davis, Steve

    1998-01-01

    The design, fabrication, and performance of K-band high-efficiency, linear power pHEMT amplifiers implemented in Embedded Transmission Line (ETL) MMIC configuration with unthinned GaAs substrate and topside grounding are reported. A three-stage amplifier achieved a power-added efficiency of 40.5% with 264 mW output at 20.2 GHz. The linear gain is 28.5 dB with 1-dB gain compression output power of 200 mW and 31% power-added efficiency. The carrier-to-third-order intermodulation ratio is approx. 20 dBc at the 1-dB compression point. A RF functional yield of more than 90% has been achieved.

  5. 29 CFR 1926.1407 - Power line safety (up to 350 kV)-assembly and disassembly.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 8 2014-07-01 2014-07-01 false Power line safety (up to 350 kV)-assembly and disassembly. 1926.1407 Section 1926.1407 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND... Cranes and Derricks in Construction § 1926.1407 Power line safety (up to 350 kV)—assembly and...

  6. 29 CFR 1926.1407 - Power line safety (up to 350 kV)-assembly and disassembly.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety (up to 350 kV)-assembly and disassembly. 1926.1407 Section 1926.1407 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND... Cranes and Derricks in Construction § 1926.1407 Power line safety (up to 350 kV)—assembly and...

  7. 29 CFR 1926.1407 - Power line safety (up to 350 kV)-assembly and disassembly.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 8 2012-07-01 2012-07-01 false Power line safety (up to 350 kV)-assembly and disassembly. 1926.1407 Section 1926.1407 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND... Cranes and Derricks in Construction § 1926.1407 Power line safety (up to 350 kV)—assembly and...

  8. A Tesla-pulse forming line-plasma opening switch pulsed power generator.

    PubMed

    Novac, B M; Kumar, R; Smith, I R

    2010-10-01

    A pulsed power generator based on a high-voltage Tesla transformer which charges a 3.85 Ω/55 ns water-filled pulse forming line to 300 kV has been developed at Loughborough University as a training tool for pulsed power students. The generator uses all forms of insulation specific to pulsed power technology, liquid (oil and water), gas (SF(6)), and magnetic insulation in vacuum, and a number of fast voltage and current sensors are implemented for diagnostic purposes. A miniature (centimeter-size) plasma opening switch has recently been coupled to the output of the pulse forming line, with the overall system comprising the first phase of a program aimed at the development of a novel repetitive, table-top generator capable of producing 15 GW pulses for high power microwave loads. Technical details of all the generator components and the main experimental results obtained during the program and demonstrations of their performance are presented in the paper, together with a description of the various diagnostic tools involved. In particular, it is shown that the miniature plasma opening switch is capable of reducing the rise time of the input current while significantly increasing the load power. Future plans are outlined in the conclusions.

  9. Experimental hybrid power transmission line with liquid hydrogen and MgB2-based superconducting cable

    NASA Astrophysics Data System (ADS)

    Kostyuk, V. V.; Antyukhov, I. V.; Blagov, E. V.; Vysotsky, V. S.; Katorgin, B. I.; Nosov, A. A.; Fetisov, S. S.; Firsov, V. P.

    2012-03-01

    Results of developing and testing an experimental hybrid power transmission line with liquid hydrogen and superconducting power (SCP) cable based on magnesium diboride (MgB2) are presented. Critical currents of the MgB2 based prototype SCP cable have been determined for the first time at the forced flow of liquid hydrogen in a temperature interval of 20-26 K. Various regimes of SCP cable cryostatting with both subcooled saturated liquid hydrogen have been tested in a broad range of supply rates (7-220 g/s) and pressures (0.15-0.4 MPa).

  10. Characteristics of low frequency electic and magnetic fields in the vicinity of electric power lines

    SciTech Connect

    Olsen, R.G. ); Wong, P.S. )

    1992-10-01

    Power engineers are often asked questions about the characteristics of low frequency electric and magnetic fields in the vicinity of power lines. Is it reasonable to use a quasi-static theory to calculate these fields Is it or is it not correct to describe these fields as radiation How can Poyntings theorem be used to address this question Why are electric and magnetic fields calculated independently when it is known that the fields satisfy the coupled Maxwells equations Under what conditions is the ratio of the electric and magnetic fields equal to the free space wave impedance Answers to these commonly asked questions are developed in this paper.

  11. Power Losses in the ILC 20-Mrad Extraction Line at 1-TeV

    SciTech Connect

    Ferrari, Arnaud; Nosochkov, Yuri; /SLAC

    2007-07-02

    The authors have performed a detailed study of the power losses in the post-collision extraction line of a TeV e{sup +}e{sup -} collider with a crossing angle of 20 mrad at the interaction point. Five cases were considered: four luminosity configurations for ILC and one for CLIC. For all of them, the strong beam-beam effects at the interaction point lead to an emittance growth for the outgoing beam, as well as to the production of beamstrahlung photons and e{sup +}e{sup -} coherent pairs. The power losses along the extraction line, which are due to energy deposition by a fraction of the disrupted beam, of the beamstrahlung photons and of the coherent pairs, were estimated in the case of ideal collisions, as well as with a vertical position or angular offset at the interaction point.

  12. A simple packet retransmission strategy for throughput and delay enhancement on power line communication channels

    SciTech Connect

    Onunga, J.O. ); Donaldson, R.W. . Dept. of Electrical Engineering)

    1993-07-01

    A new, simple, and effective communication protocol is developed and evaluated for use on power line distribution networks. The protocol involves retransmission of unacknowledged packets, which are sent in either single or multiple (N) copies in accordance with estimates of communication link quality. Multiple packet copies can be code combined at the receiver, using majority voting on each bit position, to reduce packet error rates. Adaptive link quality estimates are based on the receipt or absence of positive acknowledgements. Information throughput efficiency is calculated and N optimized in terms of system variables. Performance benefits of code combining are clearly demonstrated. The algorithm was implemented and tested using a five-station intrabuilding power line communications network operating at 1.2, 2.4, 4.8 and 9.6 kbit/s data rate. Substantial throughput and delay improvement occurred on poor quality links, without degrading performance on good links.

  13. Development of an electrical current sensor prototype for applications in high-power lines

    NASA Astrophysics Data System (ADS)

    Nascimento, I. M.; Brígida, A. C. S.; Baptista, J. M.; Costa, J. C. W. A.; Martinez, M. A. G.; Jorge, P. A. S.

    2013-11-01

    A magneto-optical current sensor, based on a low birefringence SF57 glass prism, using a dual quadrature polarimetric configuration was implemented and tested aiming its application in high voltage power lines. Sensor operation is characterized and compared using distinct Super Luminescent Diodes as optical sources, with emission at 650 nm, 830 nm and 1550 nm. Calibration and resolution are obtained in the different operating conditions using a DAQ board and full digital control for signal acquisition and processing. In particular, the sensor was tested in the range from 0 to 1 kA at 50 Hz. Also, operation at different frequencies from 50 Hz to 400 Hz was compared. A robust casing was fabricated in Nylon material enabling the portability of the sensor and its application in different types of conductors. Preliminary results indicate the feasibility of using the sensor both for metering and protection applications in high-power lines with interrogation via the OPGW cable.

  14. Development of On-Line Monitoring Systems for High Temperature Components in Power Plants

    PubMed Central

    Zhang, Hongcai; Jia, Jiuhong; Wang, Ning; Hu, Xiaoyin; Tu, Shan-Tung; Zhou, Shaoping; Wang, Zhengdong

    2013-01-01

    To accurately detect deformation and extend the component life beyond the original design limits, structural safety monitoring techniques have attracted considerable attention in the power and process industries for decades. In this paper an on-line monitoring system for high temperature pipes in a power plant is developed. The extension-based sensing devices are amounted on straight pipes, T-Joints and elbows of a main steam pipeline. During on-site monitoring for more than two years, most of the sensors worked reliably and steadily. However, the direct strain gauge could not work for long periods because of the high temperature environment. Moreover, it is found that the installation and connection of the extensometers can have a significant influence on the measurement results. The on-line monitoring system has a good alarming function which is demonstrated by detecting a steam leakage of the header. PMID:24233026

  15. Performance enhancement using forward error correction on power line communication channels

    SciTech Connect

    Chan, M.H.L. ); Friedman, D.; Donaldson, R.W. )

    1994-04-01

    The use of forward error correction (FEC) coding is investigated, to enhance communication throughput and reliability on noisy power line networks. Rate one-half self-orthogonal convolutional codes are considered. These codes are known to be effective in other environments, and can be decoded inexpensively in real-time using majority logic decoders. Extensive bit and packet error rate tests were conducted on actual, noisy in-building power line links. Coding gains of 15 dB were observed at 10[sup [minus]3] decoded bit error rates. A self-orthogonal (2, 1, 6) convolutional code with interleaving to degree 7 was particularly effective, and was implemented as a VLSI microelectronic chip. Its use improved data throughput and packet error rates substantially, at data transmission rates of 9,600 bits/s.

  16. Scaling law and general expression for transport ac loss of a rectangular thin strip with power-law E(J) relation

    NASA Astrophysics Data System (ADS)

    Chen, Du-Xing; Li, Shuo; Fang, Jin

    2015-12-01

    Transport ac loss Q of a superconducting rectangular thin strip obeying a power-law relation E∝Jn as a function of current amplitude Im may be, following Norris, expressed by normalized quantities as q(im). A scaling law is deduced that if Icf, Ic and f being the critical current and frequency, is multiplied by a positive constant C, then im and qm are multiplied by C 1 /(n - 1)and C 2 /(n - 1) , respectively. Based on this scaling law and the well-known Norris formula, the general function of q(im, n, f) is obtained graphically or analytically for any practical purpose, after accurate numerical computations on a set of q(im) at several values of n and a fixed value of f.

  17. Radiatively driven winds for different power law spectra. [for explaining narrow and broad quasar absorption lines

    NASA Technical Reports Server (NTRS)

    Beltrametti, M.

    1980-01-01

    The analytic solutions for radiatively driven winds are given for the case in which the winds are driven by absorption of line and continuum radiation. The wind solutions are analytically estimated for different parameters of the central source and for different power law spectra. For flat spectra, three sonic points can exist; it is shown, however, that only one of these sonic points is physically realistic. Parameters of the central source are given which generate winds of further interest for explaining the narrow and broad absorption lines in quasars. For the quasar model presented here, winds which could give rise to the narrow absorption lines are generated by central sources with parameters which are not realistic for quasars.

  18. Horizontal cryogenic bushing for the termination of a superconducting power-transmission line

    DOEpatents

    Minati, K.F.; Morgan, G.H.; McNerney, A.J.; Schauer, F.

    1982-07-29

    A termination for a superconducting power transmission line is disclosed which is comprised of a standard air entrance insulated vertical bushing with an elbow, a horizontal cryogenic bushing linking the pressurized cryogenic cable environment to the ambient temperature bushing and a stress cone which terminated the cable outer shield and transforms the large radial voltage gradient in the cable dielectric into a much lower radial voltage gradient in the high density helium coolant at the cold end of the cryogenic bushing.

  19. Termination for a superconducting power transmission line including a horizontal cryogenic bushing

    DOEpatents

    Minati, Kurt F.; Morgan, Gerry H.; McNerney, Andrew J.; Schauer, Felix

    1984-01-01

    A termination for a superconducting power transmission line is disclosed which is comprised of a standard air entrance insulated vertical bushing with an elbow, a horizontal cryogenic bushing linking the pressurized cryogenic cable environment to the ambient temperature bushing and a stress cone which terminates the cable outer shield and transforms the large radial voltage gradient in the cable dielectric into a much lower radial voltage gradient in the high density helium coolant at the cold end of the cryogenic bushing.

  20. High-average-power narrow-line-width sum frequency generation 589 nm laser

    NASA Astrophysics Data System (ADS)

    Lu, Yanhua; Fan, Guobin; Ren, Huaijin; Zhang, Lei; Xu, Xiafei; Zhang, Wei; Wan, Min

    2015-10-01

    An 81 W average-power all-solid-state sodium beacon laser at 589 nm with a repetition rate of 250 Hz is introduced, which is based on a novel sum frequency generation idea between two high-energy, different line widths, different beam quality infrared lasers (a 1064 nm laser and a 1319 nm laser). The 1064 nm laser, which features an external modulated CW single frequency seed source and two stages of amplifiers, can provide average-power of 150 W, beam quality M2 of ~1.8 with ultra-narrow line width (< 100 kHz). The 1319 nm laser can deliver average-power of 100 W, beam quality M2 of ~3.0 with a narrow line width of ~0.3 GHz. By sum frequency mixing in a LBO slab crystal (3 mm x 12 mm x 50 mm), pulse energy of 325 mJ is achieved at 589 nm with a conversion efficiency of 32.5 %. Tuning the center wavelength of 1064 nm laser by a PZT PID controller, the target beam's central wavelength is accurately locked to 589.15910 nm with a line width of ~0.3 GHz, which is dominated mainly by the 1319 nm laser. The beam quality is measured to be M2 < 1.3. The pulse duration is measured to be 150 μs in full-width. To the best of our knowledge, this represents the highest average-power for all-solid-state sodium beacon laser ever reported.

  1. Analysis of the grounding system for a mobile communication site placed on HV power line mast

    NASA Astrophysics Data System (ADS)

    Bîrsan, I.; Munteanu, C.; Horgoș, M.; Ilut, T.

    2016-08-01

    This paper aims to analyze the potential distribution on the soil surface or potential variation on the main directions inside computing mobile site. I want to study a system made the earth a mobile communications site, antennas operator and the system of which the earth is placed on a High Voltage Power Line Mast (LEA 110 KV). I made direct measurements and I use a 3D software for analyze the results and simulating some possible solutions.

  2. 50 CFR 29.21-8 - Electric power transmission line rights-of-way.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Electric power transmission line rights-of-way. 29.21-8 Section 29.21-8 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM LAND USE MANAGEMENT Rights-of-Way General Regulations § 29.21-8 Electric...

  3. Fiber-optic sensor for real-time monitoring of temperature on high voltage (400KV) power transmission lines

    NASA Astrophysics Data System (ADS)

    Gangopadhyay, Tarun K.; Paul, Mukul C.; Bjerkan, Leif

    2009-10-01

    On-line monitoring of temperature and sag in 400KV power transmission line has successfully been implemented by a novel device using fibre Bragg grating (FBG) sensors. The complete device has been fabricated with aluminum mount connected via fibre-optic cable and installed on ACSR power conductor for continuous two years measurement. This paper presents the excellent results and experience of the tests in controlled indoor environments conducted in Norway and real-field application on installed power conductor in India. Thus, better surveillance of the thermal and mechanical loads on power lines can be possible using this FBG sensor system.

  4. The most powerful quasar outflows as revealed by the Civ λ1549 resonance line

    NASA Astrophysics Data System (ADS)

    Marziani, P.; Martínez Carballo, M. A.; Sulentic, J. W.; Del Olmo, A.; Stirpe, G. M.; Dultzin, D.

    2016-01-01

    Outflows from quasars may be almost ubiquitous, but there are significant differences on a source- by-source basis. These differences can be organized along the 4D Eigenvector 1 sequence: at low z, only the Population A sources radiating at relatively high Eddington ratio show evidences of prominent high- velocity outflows from the Civλ1549 line profiles. Here we discuss, starting from recent observations of high-luminosity sample of Hamburg-ESO quasars, the Civλ1549 emission line profiles and how they are affected by outflow motion as a function of the quasar luminosity. Our high-luminosity sample has the notable advantage that the rest frame has been set by previous Hβ observations in the J, H, and K band, therefore making measurements of inter-line shift accurate and free of systemic biases. As the redshift increases and the luminosity of the brightest quasars grows, powerful, high-velocity outflows may become more frequent. We then discuss the outflow contextualisation following the 4DE1 approach as a tool for unveiling the nature of the so-called Weak Lined Quasars (WLQs) that have emerged in recent years as a new, poorly understood class of quasars. We estimate the kinetic power associated with the Civλ1549 emitting gas in outflow, and we suggest that the host galaxies of the most luminous sources may experience a significant feedback effect.

  5. Distributed Power-Line Outage Detection Based on Wide Area Measurement System

    PubMed Central

    Zhao, Liang; Song, Wen-Zhan

    2014-01-01

    In modern power grids, the fast and reliable detection of power-line outages is an important functionality, which prevents cascading failures and facilitates an accurate state estimation to monitor the real-time conditions of the grids. However, most of the existing approaches for outage detection suffer from two drawbacks, namely: (i) high computational complexity; and (ii) relying on a centralized means of implementation. The high computational complexity limits the practical usage of outage detection only for the case of single-line or double-line outages. Meanwhile, the centralized means of implementation raises security and privacy issues. Considering these drawbacks, the present paper proposes a distributed framework, which carries out in-network information processing and only shares estimates on boundaries with the neighboring control areas. This novel framework relies on a convex-relaxed formulation of the line outage detection problem and leverages the alternating direction method of multipliers (ADMM) for its distributed solution. The proposed framework invokes a low computational complexity, requiring only linear and simple matrix-vector operations. We also extend this framework to incorporate the sparse property of the measurement matrix and employ the LSQRalgorithm to enable a warm start, which further accelerates the algorithm. Analysis and simulation tests validate the correctness and effectiveness of the proposed approaches. PMID:25051035

  6. Distributed power-line outage detection based on wide area measurement system.

    PubMed

    Zhao, Liang; Song, Wen-Zhan

    2014-01-01

    In modern power grids, the fast and reliable detection of power-line outages is an important functionality, which prevents cascading failures and facilitates an accurate state estimation to monitor the real-time conditions of the grids. However, most of the existing approaches for outage detection suffer from two drawbacks, namely: (i) high computational complexity; and (ii) relying on a centralized means of implementation. The high computational complexity limits the practical usage of outage detection only for the case of single-line or double-line outages. Meanwhile, the centralized means of implementation raises security and privacy issues. Considering these drawbacks, the present paper proposes a distributed framework, which carries out in-network information processing and only shares estimates on boundaries with the neighboring control areas. This novel framework relies on a convex-relaxed formulation of the line outage detection problem and leverages the alternating direction method of multipliers (ADMM) for its distributed solution. The proposed framework invokes a low computational complexity, requiring only linear and simple matrix-vector operations. We also extend this framework to incorporate the sparse property of the measurement matrix and employ the LSQRalgorithm to enable a warm start, which further accelerates the algorithm. Analysis and simulation tests validate the correctness and effectiveness of the proposed approaches.

  7. AC loss of a model 5m 2G HTS power cable using wires with NiW substrates

    NASA Astrophysics Data System (ADS)

    Vysotsky, V. S.; Shutov, K. A.; Nosov, A. A.; Polyakova, N. V.; Fetisov, S. S.; Zubko, V. V.; Sytnikov, V. E.; Carter, W. L.; Fleshler, S.; Malozemoff, A. P.; Snitchler, G.

    2010-06-01

    A model 5 m cable prototype was constructed using American Superconductor second generation (2G) high temperature superconductor (HTS) wires - 344 superconductors, produced with the MOD/RABiTSTM process. The model cable consists of two helically counterwound layers of brass-laminated tapes. Twist pitches were calculated to provide uniform current distribution between the two cable layers. The NiW substrates of the tapes were oriented to face radially inward and radially outward for the inner and outer layers of the cable, respectively, to minimize the spacing between the HTS layers and any effects of the weak substrate magnetism. To verify the calculations and design principles, the model cable was instrumented with potential taps and sensors, including Rogowski coils and Hall probes, to measure the current distribution among layers, voltage - current characteristics and other parameters. AC losses in this cable model have been measured and analyzed by use of digital measurements of current and voltage. At low to intermediate currents, they are in the range of a few tenths of a watt per meter, consistent with the ferromagnetic loss of the substrate. Analysis of the individual contributions of the Ni-W substrate and the superconductor hysteresis loss is given.

  8. Alleviation SSR and Low Frequency Power Oscillations in Series Compensated Transmission Line using SVC Supplementary Controllers

    NASA Astrophysics Data System (ADS)

    Kumar, Sanjiv; Kumar, Narendra

    2016-07-01

    In this work, supplementary sub-synchronous damping controllers (SSDC) are proposed for damping sub-synchronous oscillations in power systems with series compensated transmission lines. Series compensation have extensively been used as effective means of increasing the power transfer capability of a transmission lines and improving transient stability limits of power systems. Series compensation with transmission lines may cause sub-synchronous resonance (SSR). The eigenvalue investigation tool is used to ascertain the existence of SSR. It is shown that the addition of supplementary controller is able to stabilize all unstable modes for T-network model. Eigenvalue investigation and time domain transient simulation of detailed nonlinear system are considered to investigate the performance of the controllers. The efficacies of the suggested supplementary controllers are compared on the IEEE first benchmark model for computer simulations of SSR by means of time domain simulation in Matlab/Simulink environment. Supplementary SSDC are considered in order to compare effectiveness of SSDC during higher loading in alleviating the small signal stability problem.

  9. Low-Power Testing of Losses in Millimeter-Wave Transmission Lines for High-Power Applications.

    PubMed

    Han, S T; Comfoltey, E N; Shapiro, M A; Sirigiri, J R; Tax, D S; Temkin, R J; Woskov, P P; Rasmussen, D A

    2008-11-01

    We report the measurement of small losses in transmission line (TL) components intended for high-power millimeter-wave applications. Measurements were made using two different low-power techniques: a coherent technique using a vector network analyzer (VNA) and an incoherent technique using a radiometer. The measured loss in a 140 GHz 12.7 mm diameter TL system, consisting of 1.7 m of circular corrugated waveguide and three miter bends, is dominated by the miter bend loss. The measured loss was 0.3±0.1 dB per miter bend using a VNA; and 0.22±0.1 dB per miter bend using a radiometer. Good agreement between the two measurement techniques implies that both are useful for measuring small losses. To verify the methodology, the VNA technique was employed to measure the extremely small transmission loss in a 170 GHz ITER prototype TL system consisting of three lengths of 1 m, 63.5 mm diameter, circular corrugated waveguide and two miter bends. The measured loss of 0.05±0.02 dB per miter bend may be compared with the theoretical loss of 0.027 dB per miter bend. These results suggest that low-power testing of TL losses, utilizing a small, simple TL system and a VNA, is a reliable method for evaluating performance of low-loss millimeter-wave TL components intended for use in high-power applications.

  10. Low-Power Testing of Losses in Millimeter-Wave Transmission Lines for High-Power Applications

    SciTech Connect

    Han, S. T.; Comfoltey, E. N.; Shapiro, Michael; Sirigiri, Jagadishwar R.; Tax, David; Temkin, Richard J; Woskov, P. P.; Chang, Won; Rasmussen, David A

    2008-08-01

    We report the measurement of small losses in transmission line (TL) components intended for high-power millimeter-wave applications. Measurements were made using two different low-power techniques: a coherent technique using a vector network analyzer (VNA) and an incoherent technique using a radiometer. The measured loss in a 140 GHz 12.7 mm diameter TL system, consisting of 1.7 m of circular corrugated waveguide and three miter bends, is dominated by the miter bend loss. The measured loss was 0.3 {+-} 0.1 dB per miter bend using a VNA; and 0.22 {+-} 0.1 dB per miter bend using a radiometer. Good agreement between the two measurement techniques implies that both are useful for measuring small losses. To verify the methodology, the VNA technique was employed to measure the extremely small transmission loss in a 170 GHz ITER prototype TL system consisting of three lengths of 1 m, 63.5 mm diameter, circular corrugated waveguide and two miter bends. The measured loss of 0.05 {+-} 0.02 dB per miter bend may be compared with the theoretical loss of 0.027 dB per miter bend. These results suggest that low-power testing of TL losses, utilizing a small, simple TL system and a VNA, is a reliable method for evaluating performance of low-loss millimeter-wave TL components intended for use in high-power applications.

  11. Study of high power white AC-LED based on the structure of composite bridge with SMD packaging

    NASA Astrophysics Data System (ADS)

    Wang, Zhibin; Gu, Yue; Xie, Shasha

    2010-10-01

    In this paper, a method of composite bridge structure packing with self-rectifier in the LED chips is introduced, based on the characteristics of PN junction of the high power LED. About dozens of low-power LED chips are pasted on the PCB boards which having good thermal conductivity in the form of bridge structure, regulating input voltage and current strength to make the LED chips at different bridge arms worked alternately by using of LED PN junction's own characteristics to achieve self-rectification. The copper cooling plates are sandwiched in the PCB boards to achieve for saving resource and improving brightness. During the work time, the LED flashes lights. Because of its feature of continuing light after power properties, the human eyes can not perceive the LED's flashing, their understanding on the light emitting is continuous.

  12. A Novel Uniform Discrete Multitone Transceiver with Power-Allocation for Digital Subscriber Line

    NASA Astrophysics Data System (ADS)

    Baig, Sobia; Junaid Mughal, Muhammad

    A novel Uniform Discrete Multitone (DMT) transceiver is proposed, utilizing a wavelet packet based filter bank transmultiplexer in conjunction with a DMT transceiver. The proposed transceiver decomposes the channel spectrum into subbands of equal bandwidth. The objective is to minimize the bit error rate (BER), which is increased by channel-noise amplification. This noise amplification is due to the Zero-Forcing equalization (ZFE) technique. Quantization of the channel-noise amplification is presented, based on post-equalization signal-to-noise ratio (SNR) and probability of error in all subbands of the Uniform DMT system. A modified power loading algorithm is applied to allocate variable power according to subband gains. A BER performance comparison of the Uniform DMT with variable and uniform power-loading and with a conventional DMT system in a Digital Subscriber Line (DSL) channel is presented.

  13. The effects of lightning and high altitude electromagnetic pulse on power distribution lines

    SciTech Connect

    Uman, M.A.; Rubinstein, M.; Yacoub, Z.

    1995-01-01

    We simultaneously recorded the voltages induced by lightning on both ends of an unenergized 448-meter long unenergized electric power line and the lightning vertical electric and horizontal magnetic fields at ground level near the line. The lightning data studied and presented here were due both to cloud lightning and to very close (about 20 m from the line) artificially initiated lightning. For cloud sources, a frequency-domain computer program called EMPLIN was used to calculate induced line voltages as a function of source elevation, angle of incidence, and wave polarization of the radiated cloud discharge pulses in order to compare with the measurements. For very-close lightning, the measured line voltages could be grouped into two categories, those in which multiple, similarly shaped, evenly spaced pulses were observed, which we call oscillatory, and those dominated by a principal pulse with subsidiary oscillations of much smaller amplitude, which we call impulsive. The amplitude of the induced voltage ranged from tens of kilovolts for oscillatory voltages to hundreds of kilovolts for impulsive voltages. A new technique is derived for the calculation of the electromagnetic fields from nearby lightning to ground above an imperfectly conducting ground. This technique was used in conjunction with an existing time domain coupling theory and lightning return stroke model to calculate voltages at either end of the line. The results show fair agreement with the measured oscillatory voltage waveforms if corona is ignored and improved results when corona effects are modeled. The modeling of the impulsive voltage, for which local flashover probably successful. In an attempt to understand better the sources of the line voltages for very close lightning, measurements of the horizontal and vertical electric fields 30 m from triggered lightning were obtained.

  14. Lines

    ERIC Educational Resources Information Center

    Mires, Peter B.

    2006-01-01

    National Geography Standards for the middle school years generally stress the teaching of latitude and longitude. There are many creative ways to explain the great grid that encircles our planet, but the author has found that students in his college-level geography courses especially enjoy human-interest stories associated with lines of latitude…

  15. THE JET POWER AND EMISSION-LINE CORRELATIONS OF RADIO-LOUD OPTICALLY SELECTED QUASARS

    SciTech Connect

    Punsly, Brian; Zhang Shaohua E-mail: brian.punsly@comdev-usa.com

    2011-07-01

    In this Letter, the properties of the extended radio emission form Sloan Digital Sky Survey Data Release 7 quasars with 0.4 < z < 0.8 is studied. This low-redshift sample is useful since any corresponding FIRST radio observations are sensitive enough to detect extended flux in even the weakest Fanaroff-Riley II (FR II) radio sources. In the sample, 2.7% of the sources have detectable extended emission on larger than galactic scales (>20-30 kpc). The frequency of quasars with FR II level extended radio emission is {approx}2.3% and >0.4% of quasars have FR I level extended radio emission. The lower limit simply reflects the flux density limit of the survey. The distribution of the long-term time-averaged jet powers of these quasars, Q-bar , has a broad peak {approx}3 x 10{sup 44} erg s{sup -1} that turns over below 10{sup 44} erg s{sup -1} and sources above 10{sup 45} erg s{sup -1} are extremely rare. It is found that the correlation between the bolometric (total thermal) luminosity of the accretion flow, L{sub bol}, and Q-bar is not strong. The correlation of Q-bar with narrow line luminosity is stronger than the correlation with broad line luminosity and the continuum luminosity. It is therefore concluded that previous interpretations of correlations of Q-bar with narrow line strengths in radio galaxies as a direct correlation of jet power and accretion power have been overstated. It is explained why this interpretation mistakenly overlooks the sizeable fraction of sources with weak accretion luminosity and powerful jets discovered by Ogle et al.

  16. Lumped-element model of a tapered transmission line for impedance matching in a pulsed power system

    NASA Astrophysics Data System (ADS)

    Lee, Kun-A.; Ko, Kwang-Cheol

    2016-07-01

    In a pulsed power system, impedance matching is one of the significant factors for increasing the efficiency of the system. One of the most general methods for impedance matching is to use a tapered transmission line. Because the characteristics of a tapered transmission line are changed continuously according to its position, modeling the tapered transmission line by using lumped elements is difficult. In this study, we investigated a tapered transmission line to match the impedance of power supply to that of a load by using lumped elements especially in a pulsed power system. In modeling the tapered transmission line, we used the concept of a transmission, and we introduced an efficient modeling method. We propose a simulation model based on the investigation results. The results of the study will be useful for research on tapered transmission lines.

  17. Narrow-line, tunable, high-power diode laser pump for DPAL applications

    NASA Astrophysics Data System (ADS)

    Pandey, Rajiv; Merchen, David; Stapleton, Dean; Irwin, David; Humble, Chuck; Patterson, Steve; Kissel, Heiko; Biesenbach, Jens

    2013-05-01

    We report on a high-power diode laser pump source for diode-pumped alkali lasers (DPAL), specifically rubidium alkali vapor lasers at 780nm, delivering up to 100W/bar with FWHM spectral line width of 0.06nm (~30GHz). This pump is based on a micro-channel water-cooled stack with collimation in both-axes. Wavelength-locking of the output spectrum allows absorption in one of the very narrow resonance lines of the atomic rubidium alkali vapor. To achieve these results, research was conducted to deliver the highest performance on all key components of the product from the diode laser bar which produces the optical power at 780nm to the external Bragg gratings which narrow the spectrum line width. We highlight the advancements in the epitaxy, device design, beam collimation, grating selection, alignment, tunability and thermal control that enable realization of this novel pump-source for DPALs. Design trade-offs will be presented.

  18. Mapping threats to power line corridors for Connecticut rights-of-way management.

    PubMed

    Poulos, H M; Camp, A E

    2011-02-01

    Trees are a major threat to power line security across forested regions of the world. We developed a decision support system for identifying locations in Connecticut, USA where trees have grown tall enough to make contact with transmission lines during storms. We used the Random Forest algorithm, danger tree presence/absence data, and 25 raster environmental datasets to develop (1) an understanding of the abiotic environmental settings that host danger trees and (2) a spatially explicit map of danger tree distributions across Connecticut power line corridors. Danger trees were prevalent in locations (1) with an infrequent history of storms; (2) forested and residential land uses; and (3) low to middle elevations. Products from this research can be transferred to adaptive right-of-way management because they present managers with key information on where danger trees are likely to occur, and the methods presented herein have great potential for future application to other regions managers seek to identify high priority areas for danger tree removal.

  19. Plasma evolution and dynamics in high-power vacuum-transmission-line post-hole convolutes

    NASA Astrophysics Data System (ADS)

    Rose, D. V.; Welch, D. R.; Hughes, T. P.; Clark, R. E.; Stygar, W. A.

    2008-06-01

    Vacuum-post-hole convolutes are used in pulsed high-power generators to join several magnetically insulated transmission lines (MITL) in parallel. Such convolutes add the output currents of the MITLs, and deliver the combined current to a single MITL that, in turn, delivers the current to a load. Magnetic insulation of electron flow, established upstream of the convolute region, is lost at the convolute due to symmetry breaking and the formation of magnetic nulls, resulting in some current losses. At very high-power operating levels and long pulse durations, the expansion of electrode plasmas into the MITL of such devices is considered likely. This work examines the evolution and dynamics of cathode plasmas in the double-post-hole convolutes used on the Z accelerator [R. B. Spielman , Phys. Plasmas 5, 2105 (1998)PHPAEN1070-664X10.1063/1.872881]. Three-dimensional particle-in-cell (PIC) simulations that model the entire radial extent of the Z accelerator convolute—from the parallel-plate transmission-line power feeds to the z-pinch load region—are used to determine electron losses in the convolute. The results of the simulations demonstrate that significant current losses (1.5 MA out of a total system current of 18.5 MA), which are comparable to the losses observed experimentally, could be caused by the expansion of cathode plasmas in the convolute regions.

  20. Solving Man-Induced Large-Scale Conservation Problems: The Spanish Imperial Eagle and Power Lines

    PubMed Central

    López-López, Pascual; Ferrer, Miguel; Madero, Agustín; Casado, Eva; McGrady, Michael

    2011-01-01

    Background Man-induced mortality of birds caused by electrocution with poorly-designed pylons and power lines has been reported to be an important mortality factor that could become a major cause of population decline of one of the world rarest raptors, the Spanish imperial eagle (Aquila adalberti). Consequently it has resulted in an increasing awareness of this problem amongst land managers and the public at large, as well as increased research into the distribution of electrocution events and likely mitigation measures. Methodology/Principal Findings We provide information of how mitigation measures implemented on a regional level under the conservation program of the Spanish imperial eagle have resulted in a positive shift of demographic trends in Spain. A 35 years temporal data set (1974–2009) on mortality of Spanish imperial eagle was recorded, including population censuses, and data on electrocution and non-electrocution of birds. Additional information was obtained from 32 radio-tracked young eagles and specific field surveys. Data were divided into two periods, before and after the approval of a regional regulation of power line design in 1990 which established mandatory rules aimed at minimizing or eliminating the negative impacts of power lines facilities on avian populations. Our results show how population size and the average annual percentage of population change have increased between the two periods, whereas the number of electrocuted birds has been reduced in spite of the continuous growing of the wiring network. Conclusions Our results demonstrate that solving bird electrocution is an affordable problem if political interest is shown and financial investment is made. The combination of an adequate spatial planning with a sustainable development of human infrastructures will contribute positively to the conservation of the Spanish imperial eagle and may underpin population growth and range expansion, with positive side effects on other endangered

  1. A nonlinear adaptive method of elimination of power line interference in ECG signals.

    PubMed

    Ziarani, Alireza K; Konrad, Adalbert

    2002-06-01

    A new method of elimination of power line noise in electrocardiogram signals is presented. The proposed method employs, as its main building block, a recently developed signal processing algorithm capable of extracting a specified component of a signal and tracking its variations over time. Design considerations and performance of the proposed method are presented with the aid of computer simulations. Superior performance is observed in terms of effective elimination of noise under conditions of varying powerline interference frequency. The proposed method presents a simple and robust structure which complies with practical constraints involved in the problem such as low computational resource availability and low sampling frequency.

  2. Characteristics of a four element gyromagnetic nonlinear transmission line array high power microwave source

    NASA Astrophysics Data System (ADS)

    Johnson, J. M.; Reale, D. V.; Krile, J. T.; Garcia, R. S.; Cravey, W. H.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J.

    2016-05-01

    In this paper, a solid-state four element array gyromagnetic nonlinear transmission line high power microwave system is presented as well as a detailed description of its subsystems and general output capabilities. This frequency agile S-band source is easily adjusted from 2-4 GHz by way of a DC driven biasing magnetic field and is capable of generating electric fields of 7.8 kV/m at 10 m correlating to 4.2 MW of RF power with pulse repetition frequencies up to 1 kHz. Beam steering of the array at angles of ±16.7° is also demonstrated, and the associated general radiation pattern is detailed.

  3. Characteristics of a four element gyromagnetic nonlinear transmission line array high power microwave source.

    PubMed

    Johnson, J M; Reale, D V; Krile, J T; Garcia, R S; Cravey, W H; Neuber, A A; Dickens, J C; Mankowski, J J

    2016-05-01

    In this paper, a solid-state four element array gyromagnetic nonlinear transmission line high power microwave system is presented as well as a detailed description of its subsystems and general output capabilities. This frequency agile S-band source is easily adjusted from 2-4 GHz by way of a DC driven biasing magnetic field and is capable of generating electric fields of 7.8 kV/m at 10 m correlating to 4.2 MW of RF power with pulse repetition frequencies up to 1 kHz. Beam steering of the array at angles of ±16.7° is also demonstrated, and the associated general radiation pattern is detailed. PMID:27250448

  4. Learning Rate Updating Methods Applied to Adaptive Fuzzy Equalizers for Broadband Power Line Communications

    NASA Astrophysics Data System (ADS)

    Ribeiro, Moisés V.

    2004-12-01

    This paper introduces adaptive fuzzy equalizers with variable step size for broadband power line (PL) communications. Based on delta-bar-delta and local Lipschitz estimation updating rules, feedforward, and decision feedback approaches, we propose singleton and nonsingleton fuzzy equalizers with variable step size to cope with the intersymbol interference (ISI) effects of PL channels and the hardness of the impulse noises generated by appliances and nonlinear loads connected to low-voltage power grids. The computed results show that the convergence rates of the proposed equalizers are higher than the ones attained by the traditional adaptive fuzzy equalizers introduced by J. M. Mendel and his students. Additionally, some interesting BER curves reveal that the proposed techniques are efficient for mitigating the above-mentioned impairments.

  5. Transmission line pulse system for avalanche characterization of high power semiconductor devices

    NASA Astrophysics Data System (ADS)

    Riccio, Michele; Ascione, Giovanni; De Falco, Giuseppe; Maresca, Luca; De Laurentis, Martina; Irace, Andrea; Breglio, Giovanni

    2013-05-01

    Because of the increasing in power density of electronic devices for medium and high power application, reliabilty of these devices is of great interest. Understanding the avalanche behaviour of a power device has become very important in these last years because it gives an indication of the maximum energy ratings which can be seen as an index of the device ruggedness. A good description of this behaviour is given by the static IV blocking characteristc. In order to avoid self heating, very relevant in high power devices, very short pulses of current have to be used, whose value can change from few milliamps up to tens of amps. The most used method to generate short pulses is the TLP (Transmission Line Pulse) test, which is based on charging the equivalent capacitance of a transmission line to high value of voltage and subsequently discharging it onto a load. This circuit let to obtain very short square pulses but it is mostly used for evaluate the ESD capability of semiconductor and, in this environment, it generates pulses of low amplitude which are not high enough to characterize the avalanche behaviour of high power devices . Advanced TLP circuit able to generate high current are usually very expensive and often suffer of distorption of the output pulse. In this article is proposed a simple, low cost circuit, based on a boosted-TLP configuration, which is capable to produce very square pulses of about one hundreds of nanosecond with amplitude up to some tens of amps. A prototype is implemented which can produce pulses up to 20A of amplitude with 200 ns of duration which can characterize power devices up to 1600V of breakdown voltage. Usage of microcontroller based logic make the circuit very flexible. Results of SPICE simulation are provided, together with experimental results. To prove the effectiveness of the circuit, the I-V blocking characteristics of two commercial devices, namely a 600V PowerMOS and a 1200V Trench-IGBT, are measured at different

  6. High power microwave beam steering based on gyromagnetic nonlinear transmission lines

    SciTech Connect

    Romanchenko, I. V. Rostov, V. V.; Gunin, A. V.; Konev, V. Yu.

    2015-06-07

    We demonstrate electronically controlled beam steering by high power RF pulses produced by two gyromagnetic nonlinear transmission lines (NLTLs) connected to a one high voltage driver. Each NLTL is capable of producing several ns RF pulses with peak power from 50 to 700 MW (6% standard deviation) at frequencies from 0.5 to 1.7 GHz (1% standard deviation) with 100 Hz repetition rate. Using a helix antenna allows irradiating of RF pulses with almost circular polarization and 350 MW maximum peak power, which corresponds to 350 kV effective potential of radiation. At the installation of two identical channels, we demonstrate the possibility of beam steering within ±15° in the horizontal plane by coherent RF pulses with circular polarization at 1.0 GHz center frequency. Fourfold increase in the power flux density for in-phase irradiation of RF pulses is confirmed by comparison with one-channel operation.

  7. Cascade model of gamma-ray bursts: Power-law and annihilation-line components

    NASA Technical Reports Server (NTRS)

    Harding, A. K.; Sturrock, P. A.; Daugherty, J. K.

    1988-01-01

    If, in a neutron star magnetosphere, an electron is accelerated to an energy of 10 to the 11th or 12th power eV by an electric field parallel to the magnetic field, motion of the electron along the curved field line leads to a cascade of gamma rays and electron-positron pairs. This process is believed to occur in radio pulsars and gamma ray burst sources. Results are presented from numerical simulations of the radiation and photon annihilation pair production processes, using a computer code previously developed for the study of radio pulsars. A range of values of initial energy of a primary electron was considered along with initial injection position, and magnetic dipole moment of the neutron star. The resulting spectra was found to exhibit complex forms that are typically power law over a substantial range of photon energy, and typically include a dip in the spectrum near the electron gyro-frequency at the injection point. The results of a number of models are compared with data for the 5 Mar., 1979 gamma ray burst. A good fit was found to the gamma ray part of the spectrum, including the equivalent width of the annihilation line.

  8. Treatment of biodiversity issues in impact assessment of electricity power transmission lines: A Finnish case review

    SciTech Connect

    Soederman, Tarja . E-mail: tarja.soderman@ymparisto.fi

    2006-05-15

    The Environmental Impact Assessment (EIA) process concerning the route of a 400 kV power transmission line between Loviisa and Hikiae in southern Finland was reviewed in order to assess how biodiversity issues are treated and to provide suggestions on how to improve the effectiveness of treatment of biodiversity issues in impact assessment of linear development projects. The review covered the whole assessment process, including interviews of stakeholders, participation in the interest group meetings and review of all documents from the project. The baseline studies and assessment of direct impacts in the case study were detailed but the documentation, both the assessment programme and the assessment report, only gave a partial picture of the assessment process. All existing information, baseline survey and assessment methods should be addressed in the scoping phase in order to promote interaction between all stakeholders. In contrast to the assessment of the direct effects, which first emphasized impacts on the nationally important and protected flying squirrel but later expanded to deal with the assessment of impacts on ecologically important sites, the indirect and cumulative impacts of the power line were poorly addressed. The public was given the opportunity to become involved in the EIA process. However, they were more concerned with impacts on their properties and less so on biodiversity and species protection issues. This suggests that the public needs to become more informed about locally important features of biodiversity.

  9. Use of power-line interference for adaptive motion artifact removal in biopotential measurements.

    PubMed

    Xu, Lin; Rooijakkers, Michael J; Rabotti, Chiara; Peuscher, Jan; Mischi, Massimo

    2016-01-01

    Motion artifacts (MA) have long been a problem in biopotential measurements. Adaptive filtering is widely used for optimal noise removal in many biomedical applications. However, the existing adaptive filtering methods involve the use of additional sensors, limiting the applicability of adaptive filtering for MA reduction. In the present study, a novel adaptive filtering method without need for additional sensors is proposed. In biopotential measurements, movement of the electrodes and their leads may cause variations not only in the skin and half-cell potential (motion artifacts), but also in the electrode-skin impedance. Such impedance variations may also cause power-line interference modulation (PLIM), resulting in additional spectral components around the power-line interference (PLI) in the frequency domain. Demodulation of the PLI may reflect the movement-induced electrode-skin impedance variation, and can therefore represent a reference signal for the adaptive filter. Preliminary validation on ECG measurements with seven volunteers showed a high correlation coefficient (R  =  0.97) between MA and PLIM, and excellent MA removal by the proposed adaptive filter, possibly leading to improved analysis of biopotential signals. PMID:26641265

  10. Wire Marking Results in a Small but Significant Reduction in Avian Mortality at Power Lines: A BACI Designed Study

    PubMed Central

    Barrientos, Rafael; Ponce, Carlos; Palacín, Carlos; Martín, Carlos A.; Martín, Beatriz; Alonso, Juan Carlos

    2012-01-01

    Background Collision with electric power lines is a conservation problem for many bird species. Although the implementation of flight diverters is rapidly increasing, few well-designed studies supporting the effectiveness of this costly conservation measure have been published. Methodology/Principal Findings We provide information on the largest worldwide marking experiment to date, including carcass searches at 35 (15 experimental, 20 control) power lines totalling 72.5 km, at both transmission (220 kV) and distribution (15 kV–45 kV) lines. We found carcasses of 45 species, 19 of conservation concern. Numbers of carcasses found were corrected to account for carcass losses due to removal by scavengers or being overlooked by researchers, resulting in an estimated collision rate of 8.2 collisions per km per month. We observed a small (9.6%) but significant decrease in the number of casualties after line marking compared to before line marking in experimental lines. This was not observed in control lines. We found no influence of either marker size (large vs. small spirals, sample of distribution lines only) or power line type (transmission vs. distribution, sample of large spirals only) on the collision rate when we analyzed all species together. However, great bustard mortality was slightly lower when lines were marked with large spirals and in transmission lines after marking. Conclusions Our results confirm the overall effectiveness of wire marking as a way to reduce, but not eliminate, bird collisions with power lines. If raw field data are not corrected by carcass losses due to scavengers and missed observations, findings may be biased. The high cost of this conservation measure suggests a need for more studies to improve its application, including wire marking with non-visual devices. Our findings suggest that different species may respond differently to marking, implying that species-specific patterns should be explored, at least for species of conservation

  11. On-line calibration of process instrumentation channels in nuclear power plants

    SciTech Connect

    Hashemian, H.M.; Farmer, J.P.

    1995-04-01

    An on-line instrumentation monitoring system was developed and validated for use in nuclear power plants. This system continuously monitors the calibration status of instrument channels and determines whether or not they require manual calibrations. This is accomplished by comparing the output of each instrument channel to an estimate of the process it is monitoring. If the deviation of the instrument channel from the process estimate is greater than an allowable limit, then the instrument is said to be {open_quotes}out of calibration{close_quotes} and manual adjustments are made to correct the calibration. The success of the on-line monitoring system depends on the accuracy of the process estimation. The system described in this paper incorporates both simple intercomparison techniques as well as analytical approaches in the form of data-driven empirical modeling to estimate the process. On-line testing of the calibration of process instrumentation channels will reduce the number of manual calibrations currently performed, thereby reducing both costs to utilities and radiation exposure to plant personnel.

  12. Health monitoring of electric power communication line using a distributed optical fiber sensor

    NASA Astrophysics Data System (ADS)

    Lu, Lidong; Liang, Yun; Li, Binglin; Guo, Jinghong; Zhang, Hao; Zhang, Xuping

    2014-11-01

    Optical fiber ground wire (OPGW) is used for both the earth line and communication line in electric power systems. It is important to find an effective to monitor the status of OPGW and diagnose some possible damages. Fault location of the optical fiber transmission line, lightning stroke location and early-warning of ice covering of OPGW are common tasks for OPGW health monitoring and maintenance. As to these issues, Brillouin optical time domain reflectometry (BOTDR) is employed for the health monitoring of OPGW. In experiment, a positive electrode with high pulsed current and a negative electrode are adopted to form a lightning impulse system with duration time of 200ms for simulation of the lightning stroke process, and a tensile force loading apparatus is also constructed to simulate the strain influence of the ice covering on the OPGW. Experimental results demonstrate that the BOTDR can sensitively locate the lightning stroke incidents with the quantity of electric discharging larger than 100C and the strain component has little interference on temperature monitoring as the fiber contained in the OPGW is generally free of strain, and in the ice covering condition the strain feature appears only when the extra tensile force on the OPGW is over 30kN. In addition, the vibration of OPGW does not disturb both the temperature and strain monitoring. As to further applications of distributed optical fiber sensors (DOFS) for the OPGW health monitoring, it is important to enhance its spatial resolution.

  13. High power coatings for line beam laser optics of up to 2-meter in length

    NASA Astrophysics Data System (ADS)

    Mende, Mathias; Kohlhaas, Jürgen; Ebert, Wolfgang

    2016-03-01

    Laser material processing plays an important role in the fabrication of the crucial parts for state-of-the-art smartphones and tablets. With industrial line beam systems a line shaped beam with a length above one meter and an average power of several thousand watts can be realized. To ensure excellent long axis beam homogeneity, demanding specifications regarding the substrate surface form tolerances and the coating uniformity have to be achieved for each line beam optic. In addition, a high laser damage threshold and a low defect density are required for the coatings. In order to meet these requirements, the MAXIMA ion beam sputtering machine was developed and built by LASEROPTIK. This contribution describes the functional principle of MAXIMA deposition machine, which adapts the ion beam sputtering technology with its highest coating quality to the field of large area deposition. Furthermore, recent developments regarding the process control by optical broadband monitoring are discussed. Finally experimental results on different thin film characteristics as for example the coating uniformity, the microstructure and the laser damage resistance of multilayers are presented.

  14. Losses at magnetic nulls in pulsed-power transmission line systems

    SciTech Connect

    Mendel, C.W. Jr.; Pointon, T.D.; Savage, M.E.; Seidel, D.B.; Magne, I.; Vezinet, R.

    2006-04-15

    Pulsed-power systems operating in the terawatt regime must deal with large electron flows in vacuum transmission lines. In most parts of these transmission lines the electrons are constrained by the self-magnetic field to flow parallel to the conductors. In very low impedance systems, such as those used to drive Z-pinch radiation sources, the currents from multiple transmission lines are added together. This addition necessarily involves magnetic nulls that connect the positive and negative electrodes. The resultant local loss of magnetic insulation results in electron losses at the anode in the vicinity of the nulls. The lost current due to the magnetic null might or might not be appreciable. In some cases the lost current due to the null is not large, but is spatially localized, and may create a gas and plasma release from the anode that can lead to an excessive loss, and possibly to catastrophic damage to the hardware. In this paper we describe an analytic model that uses one geometric parameter (aside from straightforward hardware size measurements) that determines the loss to the anode, and the extent of the loss region when the driving source and load are known. The parameter can be calculated in terms of the magnetic field in the region of the null calculated when no electron flow is present. The model is compared to some experimental data, and to simulations of several different hardware geometries, including some cases with multiple nulls, and unbalanced feeds.

  15. Losses at magnetic nulls in pulsed-power transmission line systems.

    SciTech Connect

    Magne, I.; Savage, Mark Edward; Seidel, David Bruce; Mendel, Clifford Will, Jr.; Pointon, Timothy David; Vezinet, R.

    2004-08-01

    Pulsed-power systems operating in the terawatt regime must deal with large electron flows in vacuum transmission lines. In most parts of these transmission lines the electrons are constrained by the self-magnetic field to flow parallel to the conductors. In very low impedance systems, such as those used to drive Z-pinch radiation sources, the currents from multiple transmission lines are added together. This addition necessarily involves magnetic nulls that connect the positive and negative electrodes. The resultant local loss of magnetic insulation results in electron losses at the anode in the vicinity of the nulls. The lost current due to the magnetic null might or might not be appreciable. In some cases the lost current due to the null is not large, but is spatially localized, and may create a gas and plasma release from the anode that can lead to an excessive loss, and possibly to catastrophic damage to the hardware. In this paper we describe an analytic model that uses one geometric parameter (aside from straightforward hardware size measurements) that determines the loss to the anode, and the extent of the loss region when the driving source and load are known. The parameter can be calculated in terms of the magnetic field in the region of the null calculated when no electron flow is present. The model is compared to some experimental data, and to simulations of several different hardware geometries, including some cases with multiple nulls, and unbalanced feeds.

  16. A fast, robust algorithm for power line interference cancellation in neural recording

    NASA Astrophysics Data System (ADS)

    Keshtkaran, Mohammad Reza; Yang, Zhi

    2014-04-01

    Objective. Power line interference may severely corrupt neural recordings at 50/60 Hz and harmonic frequencies. The interference is usually non-stationary and can vary in frequency, amplitude and phase. To retrieve the gamma-band oscillations at the contaminated frequencies, it is desired to remove the interference without compromising the actual neural signals at the interference frequency bands. In this paper, we present a robust and computationally efficient algorithm for removing power line interference from neural recordings. Approach. The algorithm includes four steps. First, an adaptive notch filter is used to estimate the fundamental frequency of the interference. Subsequently, based on the estimated frequency, harmonics are generated by using discrete-time oscillators, and then the amplitude and phase of each harmonic are estimated by using a modified recursive least squares algorithm. Finally, the estimated interference is subtracted from the recorded data. Main results. The algorithm does not require any reference signal, and can track the frequency, phase and amplitude of each harmonic. When benchmarked with other popular approaches, our algorithm performs better in terms of noise immunity, convergence speed and output signal-to-noise ratio (SNR). While minimally affecting the signal bands of interest, the algorithm consistently yields fast convergence (<100 ms) and substantial interference rejection (output SNR >30 dB) in different conditions of interference strengths (input SNR from -30 to 30 dB), power line frequencies (45-65 Hz) and phase and amplitude drifts. In addition, the algorithm features a straightforward parameter adjustment since the parameters are independent of the input SNR, input signal power and the sampling rate. A hardware prototype was fabricated in a 65 nm CMOS process and tested. Software implementation of the algorithm has been made available for open access at https://github.com/mrezak/removePLI. Significance. The proposed

  17. Power lines: Urban space, energy development and the making of the modern Southwest

    NASA Astrophysics Data System (ADS)

    Needham, Todd Andrew

    "Power Lines: Urban Space, Energy Development, and the Making of the Modern Southwest" explores the social and environmental transformation of the postwar Southwest and the resulting disputes between urban boosters, federal officials, Native Americans, and environmental activists. The dissertation focuses on the infrastructure built to provide the burgeoning populations of Phoenix, Los Angeles, and other Southwestern cities with electricity. This infrastructure allowed metropolitan boosters in the Southwest to attract Cold War defense manufacturing and to build a new suburban landscape even as industrialization on Indian lands provided electricity for those landscapes. Tracing the transition of electrical generation from a dispersed geography relying on local resources to a centralized geography utilizing primarily coal from Navajo land, "Power Lines" demonstrates the increasing centrality of Indian lands and labor to the metropolitan Southwest. Paying close attention to these networks reveals the far-reaching changes caused by postwar metropolitan growth. "Power Lines" challenges understandings of urban space that neglect the material resources that allow cities to "live." As the nation's cities and suburbs became increasingly energy-intensive, electrical utilities reached deep into the metropolitan periphery, transforming landscapes hundreds of miles from city centers into urban space. The construction of the new "geography of power" in the Southwest also reflects the impact of growth liberalism on postwar growth, as federal money funded suburban, manufacturing, and infrastructure developments. This pursuit of growth produced new political struggles, both as the development of energy resources conflicted with emerging environmentalist sensibilities and as American Indians increasingly resented the industrialization of their land for the benefit of others. By the 1970s, the simultaneous pursuit and criticism of growth came to define the modern Southwest. The

  18. Application of offset-CT scanning to the inspection of high power feeder lines and connections

    NASA Astrophysics Data System (ADS)

    Schneberk, Daniel; Maziuk, Robert; Soyfer, Boris; Shashishekhar, N.; Alreja, Rahul

    2016-02-01

    VJT is developing techniques and scanning methods for the in-situ Radiographic and Computed Tomographic inspection of underground high-power feeder cables. The goals for the inspection are to measure the 3D state of the cables and the cable-connections. Recent in-situ Digital Radiographic inspections performed by VJT have demonstrated the value of NDE inspection information for buried power lines. These NDE data have raised further questions as to the exact state of the cables and connections and pointed to the need for more 3D information of the type provided by volumetric CT scanning. VJT is pursuing a three phased approach to address the many issues involved in this type of inspection: 1) develop a high-power feeder-cable test-bed CT scanner, 2) acquire scans on underground feeder pipes that have been removed from service, and 3) from the work in 1) and 2) develop limited-angle CT scanning methods for extending in-situ Digital Radiography to volumetric CT measurements. To this end, VJT has developed and fielded a high-energy test-bed Gantry-type CT scanner (the source and detector move around the object) with a number of important properties. First, the geometry of the gantry-scans can be configured to match the techniques used in the in-situ radiographic inspection. The same X-ray source is employed as in portable Radiographic inspections, a 7.5 MeV Betatron coupled to a Perkin-Elmer Amorphous Silicon detector. Offset-CT scanning is employed as the high-power feeder line assembly is larger than the detector. A description of this scanner and the scan geometry will be presented showing the connection to in-situ radiography. Results from the CT scans of high-power feeder-cable specimens removed from service will be presented with a focus on the inspection potential of volumetric CT data on these assemblies. An evaluation of the scan performance properties of these data compared to the spectrum of life-cycle inspection issues will be presented. Continuing and

  19. Angular power spectrum of sterile neutrino decay lines: the role of eROSITA

    NASA Astrophysics Data System (ADS)

    Zandanel, Fabio; Weniger, Christoph; Ando, Shin’ichiro

    2016-05-01

    We study the potential of the angular auto and cross-correlation power spectrum of the cosmic X-ray background in identifying sterile neutrino dark matter taking as reference the performances of the soon-to-be-launched eROSITA satellite. The main astrophysical background sources in this case are active galactic nuclei, galaxies powered by X-ray binaries, and clusters of galaxies. We show that while sterile neutrino decays are always subdominant in the autocorrelation power spectra, they can be efficiently enhanced when cross-correlating with tracers of the dark matter distribution. We estimate that the four-years eROSITA all-sky survey will potentially provide very stringent constraints on the sterile neutrino decay lifetime by cross-correlating the cosmic X-ray background with the 2MASS galaxy catalogue. This will allow to firmly test the recently claimed 3.56-keV X-ray line found towards several clusters and galaxies and its decaying dark matter interpretation. We finally stress that the main limitation of this approach is due to the shot noise of the galaxy catalogues used as tracers for the dark matter distribution, a limitation that we need to overcome to fully exploit the potential of the eROSITA satellite in this context.

  20. Ergonomics hazards analysis of linemen's power line fixing work in China.

    PubMed

    Yu, Ming; Sun, Linyan; Du, Jianhua; Wu, Fengge

    2009-01-01

    This study used qualitative and quantitative methods, such as OWAS (Ovako working posture analysis system) and behavior observation, to analyze musculoskeletal disorder (MSD) risk factors of power line fixing work in China. Video-based sampling was used to record and analyze the frequency and posture of on-pole activities. Those key subtasks showed ergonomics characteristics of on-pole fixing tasks. Insulator-fixing was the longest subtask (33% of total working time). Bar-installing was the second longest (26% of total working time). It was evident that bar-installing and insulator-fixing were full of hazardous risks. The action categories of the 2 subtasks were higher than of the other ones. The 2 subtasks were also time-consuming, difficult and induced MSDs. Assistant linemen faced more hazardous factors than chief linemen.

  1. Unsupervised learning technique for surface electromyogram denoising from power line interference and baseline wander.

    PubMed

    Niegowski, Maciej; Zivanovic, Miroslav; Gomez, Marisol; Lecumberri, Pablo

    2015-08-01

    We present a novel approach to single-channel power line interference (PLI) and baseline wander (BW) removal from surface electromyograms (EMG). It is based on non-negative matrix factorization (NMF) using a priori knowledge about the interferences. It performs a linear decomposition of the input signal spectrogram into non-negative components, which represent the PLI, BW and EMG spectrogram estimates. They all exhibit very different time-frequency patterns: PLI and BW are both sparse whereas EMG is noise-like. Initialization of the classical NMF algorithm with accurately designed PLI, BW and EMG structures and a carefully adjusted matrix decomposition rank increases the separation performance. The comparative study suggests that the proposed method outperforms two state-of-the-art reference methods. PMID:26737971

  2. Line-focus solar central power system, phase I. Subsystem experiment: receiver heat transfer

    SciTech Connect

    Slemmons, A J

    1980-04-01

    Wind-tunnel tests confirmed that heat losses due to natural convection are negligible in the line-focus, solar-powered receiver. Anomalies in the forced-convection tests prevented definitive conclusions regarding the more important forced convection. Flow-visualization tests using a water table show much lower velocities inside the receiver cavity than outside, supporting the supposition that the forced-heat transfer should be less than that from a standard exposed cylinder. Furthermore, the water-table tests showed ways to decrease the low velocities in the cavity should this be desired. Further wind-tunnel testing should be done to confirm estimates and to support advanced design. This testing can be done in standard wind tunnels since only the forced convection is of concern.

  3. Power system distributed on-line fault section estimation using decision tree based neural nets approach

    SciTech Connect

    Yang, H.T.; Chang, W.Y.; Huang, C.L.

    1995-01-01

    This paper proposes a distributed neural nets decision approach to on-line estimation of the fault section of a transmission and distribution (T and D) system. The distributed processing alleviates the burden of communication between the control center and local substations, and increases the reliability and flexibility of the diagnosis system. Besides, by using the algorithms of data-driven decision tree induction and direct mapping from the decision tree into neural net, the proposed diagnosis system features parallel processing and easy implementation, overcoming the limitations of overly large and complex system. The approach has been practically tested on a typical Taiwan Power (Taipower) T and D system. The feasibility of such a diagnosis system is presented.

  4. Robust suppression of nonstationary power-line interference in electrocardiogram signals.

    PubMed

    Li, Guojun; Zeng, Xiaopin; Zhou, Xiaona; Zhou, Yu; Liu, Guojin; Zhou, Xichuan

    2012-07-01

    It is a challenge to suppress time-varying power-line interference (PLI) with various levels in electrocardiogram (ECG) signals. Most previous attempts of tracking and suppressing the nonstationary PLI signal are based on the least-squares (LS) algorithm. This makes these methods susceptible to QRS complex in suppressing a low-level PLI signal which is frequently coupled in battery-operated ECG equipment. To address the limitation of LS-based methods, this study presents a robust PLI suppression system based on a robust extension of the Kalman filter. In addition, we used an improved version of empirical mode decomposition to further attenuate the QRS complex. Experiments show that our system could effectively suppress the PLI while preserving meaningful ECG components at various interference levels.

  5. Measurements of induced voltages and currents in a distribution power line and associated atmospheric parameters

    NASA Technical Reports Server (NTRS)

    Santiago-Perez, Julio

    1988-01-01

    The frequency and intensity of thunderstorms around the Kennedy Space Center (KSC) has affected scheduled launch, landing, and other ground operations for many years. In order to protect against and provide safe working facilities, KSC has performed and hosted several studies on lightning phenomena. For the reasons mentioned above, KSC has established the Atmospheric Science Field Laboratory (ASFL). At these facilities KSC launches wire-towing rockets into thunderstorms to trigger natural lightning to the launch site. A program named Rocket Triggered Lightning Program (RTLP) is being conducted at the ASFL. This report calls for two of the experiments conducted in the summer 1988 Rocket Triggered Lightning Program. One experiment suspended an electric field mill over the launching areas from a balloon about 500 meters high to measure the space charges over the launching area. The other was to connect a waveform recorder to a nearby distribution power line to record currents and voltages wave forms induced by natural and triggered lightning.

  6. Survey of ELF magnetic field levels in households near overhead power lines in Serbia.

    PubMed

    Vulevic, B; Osmokrovic, P

    2011-06-01

    During the last eight years, 'VINČA' Institute--Radiation and Environmental Protection Laboratory has performed environmental 'spot' broadband measurements of extremely low frequency (ELF-50 Hz) electric and magnetic fields and RF (100 kHz-3 GHz) electromagnetic fields in over 35 municipalities in Serbia. These investigations were motivated by the local population requesting information about levels of general public exposure to time-varying electric and magnetic fields in living spaces. This paper presents a summary of values measured in households under overhead power lines. These measurements will be useful in determining the exposure levels of the general public, which in turn determines whether the exposure levels are within reference levels recommended by International Commission on Non-Ionizing Radiation Protection (ICNIRP) Guidelines. It has turned out that measured values are far below the recommended safe levels. PMID:21273197

  7. AC resistance measuring instrument

    DOEpatents

    Hof, P.J.

    1983-10-04

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.

  8. AC Resistance measuring instrument

    DOEpatents

    Hof, Peter J.

    1983-01-01

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument.

  9. On-line mechanical tube cleaning for steam electric power plants. Final report

    SciTech Connect

    Not Available

    1994-02-18

    In July 1991, Superior I.D. Tube Cleaners, Inc. (SIDTEC{trademark}) received a grant through the Department of Energy and the Energy Related Invention Program to conduct a long term demonstration of a proprietary technology for on-line mechanical condenser tube cleaning in thermal Power plants on open or once-through cooling water systems where the warmed condenser cooling water is discharged through a canal. The purpose of the demonstration was to confirm and establish the use of this mechanical method as an alternative to the application of chemical biocides in condenser cooling water for the control of biofouling, the growth of micro-organisms which can reduce a unit`s operating efficiency. The SIDTEC on-line mechanical tube cleaner, the Rocket{trademark}, is used to physically remove accumulated deposits on the water side of the main steam condenser, and the non-intrusive tube cleaner recovery system, the Skimmer{trademark}, is used to recover and recirculate tube cleaners. The periodic circulation of tube cleaners can maintain optimum condenser cleanliness and improve unit heat rate. Thermal power plants which discharge condenser cooling water through a canal now have a viable alternative to the chemical treatment of condenser cooling water, whether the principal foulant is biofouling, chemical scaling, silting, or a combination of the three. At prices competitive with scale inhibitors, and a fraction of competing mechanical systems, this technology is provided as a service requiring no capital investment; minimal retrofit modifications to plant structures or equipment; can be installed and maintained without a unit shutdown; does not add any restrictions in the cooling water system; and is environmentally benign.

  10. Overhead electric power transmission line jumpering system for bundles of five or more subconductors

    DOEpatents

    Winkelman, Paul F.

    1982-01-01

    Jumpering of electric power transmission lines at a dead end tower. Two transmission line conductor bundles each contain five or more spaced apart subconductors (5) arranged in the shape of a cylinder having a circular cross section. The ends of each bundle of subconductors are attached with insulators to a dead end tower (1). Jumpering allows the electric current to flow between the two bundles of subconductors using jumper buses, internal jumper conductors, and external jumper conductors. One or more current collecting jumper buses (37) are located inside each bundle of subconductors with each jumper bus being attached to the end of a subconductor. Small-diameter internal jumper conductors (33) are located in the inherently electrically shielded area inside each bundle of subconductors with each subconductor (except ones having an attached jumper bus) having one internal jumper conductor connected between that subconductor's end and a jumper bus. Large-diameter external jumper conductors (9) are located outside each bundle of subconductors with one or more external jumper conductors being connected between the jumper buses in one bundle of subconductors and the jumper buses in the other bundle.

  11. Line-Focus Solar Power Plant Cost Reduction Plan (Milestone Report)

    SciTech Connect

    Kutscher, C.; Mehos, M.; Turchi, C.; Glatzmaier, G.; Moss, T.

    2010-12-01

    Line-focus solar collectors, in particular parabolic trough collectors, are the most mature and proven technology available for producing central electricity from concentrated solar energy. Because this technology has over 25 years of successful operational experience, resulting in a low perceived risk, it is likely that it will continue to be a favorite of investors for some time. The concentrating solar power (CSP) industry is developing parabolic trough projects that will cost billions of dollars, and it is supporting these projects with hundreds of millions of dollars of research and development funding. While this technology offers many advantages over conventional electricity generation -- such as utilizing plentiful domestic renewable fuel and having very low emissions of greenhouse gases and air pollutants -- it provides electricity in the intermediate power market at about twice the cost of its conventional competitor, combined cycle natural gas. The purpose of this document is to define a set of activities from fiscal year 2011 to fiscal year 2016 that will make this technology economically competitive with conventional means.

  12. Implementation of an on-line monitoring system for transmitters in a CANDU nuclear power plant

    NASA Astrophysics Data System (ADS)

    Labbe, A.; Abdul-Nour, G.; Vaillancourt, R.; Komljenovic, D.

    2012-05-01

    Many transmitters (pressure, level and flow) are used in a nuclear power plant. It is necessary to calibrate them periodically to ensure that their measurements are accurate. These calibration tasks are time consuming and often contribute to worker radiation exposure. Human errors can also sometimes degrade their performance since the calibration involves intrusive techniques. More importantly, experience has shown that the majority of current calibration efforts are not necessary. These facts motivated the nuclear industry to develop new technologies for identifying drifting instruments. These technologies, well known as on-line monitoring (OLM) techniques, are non-intrusive and allow focusing the maintenance efforts on the instruments that really need a calibration. Although few OLM systems have been implemented in some PWR and BWR plants, these technologies are not commonly used and have not been permanently implemented in a CANDU plant. This paper presents the results of a research project that has been performed in a CANDU plant in order to validate the implementation of an OLM system. An application project, based on the ICMP algorithm developed by EPRI, has been carried out in order to evaluate the performance of an OLM system. The results demonstrated that the OLM system was able to detect the drift of an instrument in the majority of the studied cases. A feasibility study has also been completed and has demonstrated that the implementation of an OLM system at a CANDU nuclear power plant could be advantageous under certain conditions.

  13. A novel modular approach to active power-line harmonic filtering in distribution systems

    NASA Astrophysics Data System (ADS)

    El Shatshat, Ramadan A.

    The objective of this research is to develop an efficient and reliable modular active harmonic filter system to realize a cost-effective solution to the harmonic problem. The proposed filter system consists of a number CSC modules, each dedicated to filter a specific harmonic of choice (Frequency-Splitting Approach). The power rating of the modules will decrease and their switching frequency will increase as the order of the harmonic to be filtered is increased. The overall switching losses are minimized due to the selected harmonic elimination and balanced a "power rating"-"switching frequency" product. Two ADALINEs are proposed as a part of the filter controller for processing the signals obtained from the power-line. One ADALINE (the Current ADALINE) extracts the fundamental and harmonic components of the distorted current. The other ADALINE (the Voltage ADALINE) estimates the line voltage. The outputs of both ADALINEs are used to construct the modulating signals of the filter modules. The proposed controller decides which CSC filter module(s) is connected to the electric grid. The automated connection of the corresponding filter module(s) is based on decision-making rules in such a way that the IEEE 519-1992 limits are not violated. The information available on the magnitude of each harmonic component allows us to select the active filter bandwidth (i.e., the highest harmonic to be suppressed). This will result in more efficiency and higher performance. The proposed controller adjusts the I dc in each CSC module according to the present magnitude of the corresponding harmonic current. This results in optimum dc-side current value and minimal converter losses. The comparison of the proposed modular active filter scheme and the conventional one converter scheme on practical use in industry is presented. This comparison shows that the proposed solution is more economical, reliable and flexible compared to conventional one. High speed and accuracy of ADALINE, self

  14. Solving the 56Ni Puzzle of Magnetar-powered Broad-lined Type IC Supernovae

    NASA Astrophysics Data System (ADS)

    Wang, Ling-Jun; Han, Yan-Hui; Xu, Dong; Wang, Shan-Qin; Dai, Zi-Gao; Wu, Xue-Feng; Wei, Jian-Yan

    2016-11-01

    Broad-lined Type Ic supernovae (SNe Ic-BL) are of great importance because their association with long-duration gamma-ray bursts (LGRBs) holds the key to deciphering the central engine of LGRBs, which refrains from being unveiled despite decades of investigation. Among the two popularly hypothesized types of central engine, i.e., black holes and strongly magnetized neutron stars (magnetars), there is mounting evidence that the central engine of GRB-associated SNe (GRB-SNe) is rapidly rotating magnetars. Theoretical analysis also suggests that magnetars could be the central engine of SNe Ic-BL. What puzzled the researchers is the fact that light-curve modeling indicates that as much as 0.2{--}0.5 {M}ȯ of 56Ni was synthesized during the explosion of the SNe Ic-BL, which is unfortunately in direct conflict with current state-of-the-art understanding of magnetar-powered 56Ni synthesis. Here we propose a dynamic model of magnetar-powered SNe to take into account the acceleration of the ejecta by the magnetar, as well as the thermalization of the injected energy. Assuming that the SN kinetic energy comes exclusively from the magnetar acceleration, we find that although a major fraction of the rotational energy of the magnetar is to accelerate the SN ejecta, a tiny fraction of this energy deposited as thermal energy of the ejecta is enough to reduce the needed 56Ni to 0.06 M ⊙ for both SN 1997ef and SN 2007ru. We therefore suggest that magnetars could power SNe Ic-BL in aspects both of energetics and of 56Ni synthesis.

  15. Comparative analysis of wireless systems as alternative to high-voltage power lines for global terrestrial power transmission

    SciTech Connect

    Smakhtin, A.P.; Rybakov, V.V.

    1996-12-31

    This paper discusses the problem of creating the global terrestrial power transmission system, the method to analyze alternative systems including such non traditional systems as wireless power transmission systems. From the above discussion it appears that using microwave beam power transmission with an orbital reflector may be more effective in the case of power transportation between two very distant regions on the Earth, right up to the power transportation between two continents.

  16. The Power Behind the Controversy: Understanding Local Policy Elites' Perceptions on the Benefits and Risks Associated with High Voltage Power Line Installation in the State of Arkansas

    NASA Astrophysics Data System (ADS)

    Moyer, Rachael M.

    Following a proposal for the installation of high voltage power lines in northwest Arkansas, a controversial policy debate emerged. Proponents of the transmission line argue that such an installation is inevitable and necessary to efficiently and reliably support the identified electric load in the region. Opponents claim that the lines will degrade the natural environment and hamper the tourism-based local economy in affected regions, notably in Ozark Mountain areas. This study seeks to understand how local policy elites perceive the benefits and risks associated with proposed transmission lines, which is a critical step in comprehending the formation and changes of related government policies. First, based upon the dual process theory of judgment, this study systematically investigates the triadic relationships between (a) more profound personal value predispositions, (b) affects and feelings, and (c) perceived benefits and risks related to the proposed installation of high voltage power lines among local policy elites in the state of Arkansas. Next, this study focuses more specifically on the role of value predispositions, specific emotional dimensions of affect heuristics, and perceptions pertaining to high voltage power line risks and benefits. Using original data collected from a statewide Internet survey of 420 local leaders and key policymakers about their opinions on the related issues, other factors claimed by previous literature, including trust, knowledge level, and demographic characteristics are considered. Analytical results suggest that grid-group cultural predispositions, as deeply held core values within local policy elites' individual belief systems, both directly and indirectly -- through affective feelings -- shape perceived utility associated with the installation of high voltage power lines. Recognizing that risk perceptions factor into policy decisions, some practical considerations for better designing policy addressing controversial issues

  17. Adaptive settings of distance relay for MOV-protected series compensated line with distributed capacitance considering wind power

    NASA Astrophysics Data System (ADS)

    Sivov, Oleg Viktorovich

    Series compensated lines are protected from overvoltage by metal-oxide-varistors (MOVs) connected in parallel with the capacitor bank. The nonlinear characteristics of MOV devices add complexity to fault analysis and distance protection operation. During faults, the impedance of the line is modified by an equivalent impedance of the parallel MOV/capacitor circuit, which affects the distance protection. The intermittent wind generation introduces additional complexity to the system performance and distance protection. Wind variation affects the fault current level and equivalent MOV/capacitor impedance during a fault, and hence the distance relay operation. This thesis studies the impact of the intermittent wind power generation on the operation of MOV during faults. For the purpose of simulation, an equivalent wind farm model is proposed to generate a wind generation profile using wind farm generation from California independent system operator (ISO) as a guide for wind power variation to perform the study. The IEEE 12-bus test system is modified to include MOV-protected series capacitor and the equivalent wind farm model. The modified test system is simulated in the MATLAB/Simulink environment. The study has been achieved considering three phase and single line to ground (SLG) faults on the series compensated line to show the effect of wind variation on the MOV operation. This thesis proposes an adaptive setting method for the mho relay distance protection of series compensated line considering effects of wind power variation and MOV operation. The distributed parameters of a transmission line are taken into account to avoid overreaching and underreaching of distance relays. The study shows that variable wind power affects system power flow and fault current in the compensated line during a fault which affects the operation of MOVs for different fault conditions. The equivalent per-phase impedance of the MOV/capacitor circuit has an effect on the system operation

  18. METALLICITIES OF EMISSION-LINE GALAXIES FROM HST ACS PEARS AND HST WFC3 ERS GRISM SPECTROSCOPY AT 0.6 < z < 2.4

    SciTech Connect

    Xia Lifang; Malhotra, Sangeeta; Rhoads, James; Cohen, Seth; Windhorst, Rogier A.; Pirzkal, Nor; Straughn, Amber; Finkelstein, Steven; Kuntschner, Harald; Kuemmel, Martin; Walsh, Jeremy; O'Connell, Robert

    2012-07-15

    Galaxies selected on the basis of their emission-line strength show low metallicities, regardless of their redshifts. We conclude this from a sample of faint galaxies at redshifts between 0.6 < z < 2.4, selected by their prominent emission lines in low-resolution grism spectra in the optical with the Advanced Camera for Surveys on the Hubble Space Telescope and in the near-infrared using Wide-Field Camera 3. Using a sample of 11 emission-line galaxies at 0.6 < z < 2.4 with luminosities of -22 {approx}< M{sub B} {approx}< -19 which have [O II], H{beta}, and [O III] line flux measurements from the combination of two grism spectral surveys, we use the R23 method to derive the gas-phase oxygen abundances: 7.5 < 12 + log (O/H) < 8.5. The galaxy stellar masses are derived using Bayesian-based Markov Chain Monte Carlo ({pi}MC{sup 2}) fitting of their spectral energy distribution, and span the mass range 8.1 < log (M{sub *}/M{sub Sun} ) < 10.1. These galaxies show mass-metallicity (M-Z) and luminosity-metallicity (L-Z) relations, which are offset by -0.6 dex in metallicity at given absolute magnitude and stellar mass relative to the local Sloan Digital Sky Survey galaxies, as well as continuum-selected DEEP2 samples at similar redshifts. The emission-line-selected galaxies most resemble the local 'green peas' galaxies and Ly{alpha} galaxies at z {approx_equal} 0.3 and z {approx_equal} 2.3 in the M-Z and L-Z relations and their morphologies. The G - M{sub 20} morphology analysis shows that 10 out of 11 show disturbed morphology, even as the star-forming regions are compact. These galaxies may be intrinsically metal poor, being at early stages of formation, or the low metallicities may be due to gas infall and accretion due to mergers.

  19. Why arguments based on photon energy may be highly misleading for power line frequency electromagnetic fields.

    PubMed

    Vistnes, A I; Gjötterud, K

    2001-04-01

    When evaluating possible mechanisms by which low frequency electromagnetic fields may have a biological effect, arguments based on photon energy have often been used in a misleading way. For visible light the concept of photons has proved to be very useful in explaining experimental findings. However, the concept of photons cannot be used without major modifications in describing phenomena related to near field problems at power frequency (50 or 60 Hz) electric and magnetic fields. For this regime, the photon description is very complex. A very high number of highly coherent photons must be used in a quantum electrodynamic description of low frequency electromagnetic field phenomena. Thus, one-photon interaction descriptions must be replaced by multiple-photon interaction formalism. However, at low frequencies, a classical electromagnetic field description is far more useful than quantum electrodynamics. There is in principle no difference in how much energy an electron can pick up from a low frequency electric field as compared to from a high frequency photon. Thus, the total gain in energy is not limited to the energy carried by a single photon, which is E = hv, where h is Planck's constant and (v) is the frequency of the radiation. However, the time scale of the primary event in a mechanism of action is very different for ionizing radiation compared to power line frequency fields. The advice is to consider the time scale given by the inverse of the frequency of the fields, rather than photon energy, when one use physics as a guidance in evaluating possible mechanisms for biological effects from low frequency electromagnetic fields.

  20. 140 W high power all-fiber laser at 1940 nm with narrow spectral line-width by MOPA configuration

    NASA Astrophysics Data System (ADS)

    Yang, C.; Ju, Y. L.; Yao, B. Q.; Dai, T. Y.; Duan, X. M.; Zhang, Z. G.; Liu, W.

    2016-08-01

    We report a diode-pumped Tm3+-doped double-clad all-fiber laser operating at 1940 nm with a master oscillator power amplifier configuration; 50 W of seed was generated in master oscillator with 144 W pump power, corresponding to a slope efficiency of 40.1 %. With 212 W pump power, the seed was amplified to 140.9 W in power amplifier, corresponding to a slope efficiency of 47.1 %. The peak wavelength was 1939.57 nm with a narrow spectral line-width of 0.09 nm. The beam quality factor of M 2 was 1.29. Neither amplified spontaneous emission nor parasitic lasing was observed during the amplification process. The output power was only limited by the pump power.

  1. Small-Signal ac Analysis

    NASA Technical Reports Server (NTRS)

    Jagielski, James M.; Chen, Jess

    1987-01-01

    Program simulates power circuits and systems. Small Signal A.C. Analysis program (SSAC) valuable tool for design and analysis of electrical-power-system circuits. By combining "black box" power-system components operating in specified manner, user characterizes system modeled. Menu-driven program proved simple and cost effective in development and modification of arbitrary power-system configurations. Package includes sample data from Dynamic Explorer satellite family. Results compared favorable to calculations from such general circuit-analysis programs as SPICE. Written in FORTRAN 77.

  2. An On-Chip Noise Canceller with High Voltage Supply Lines for Nanosecond-Range Power Supply Noise

    NASA Astrophysics Data System (ADS)

    Nakamura, Yasumi; Takamiya, Makoto; Sakurai, Takayasu

    An on-chip power supply noise canceller with higher voltage supply and switching transistor is proposed and the effectiveness of the canceller is experimentally verified. The noise canceller is effective for nano-second order noise caused by circuit wakeup or step increase of frequency in frequency hopping. The principle of the noise canceller is to reduce the current flowing through the supply line of VDD by injecting additional current from the higher voltage supply, so that the voltage drop across the VDD supply line is reduced. As additional current flow from higher supply, switching transistor has to be turned off not to increase the power consumption. With turn-off time of 2L/R, this current can be turned off without inducting another droop due to the increase of current flowing through the power supply line. The measurement shows the canceller reduces 68% of the noise with load circuit equivalent to 530k logic gates in 90-nm CMOS with 9% wire overhead, 1.5% area overhead, and 3% power overhead at 50k wake-ups/s. Compared to passive noise reduction, proposed noise canceller reduces power supply noise by 64% without wire overhead and to achieve same noise reduction with passive method, 77 times more C or 45 times less L is required. Too large switching transistor results in saturated noise reduction effect and higher power consumption. A rule-of-thumb is to set the on-resistance to supply 100% of load current when turned-on.

  3. Electrocution of Raptors on Power Lines: A Review of Necropsy Methods and Findings.

    PubMed

    Kagan, R A

    2016-09-01

    Decades after the problem was first identified, power line electrocution continues to be a cause of avian mortality. Currently, several federal laws protect eagles and other migratory birds, meaning that utility companies may be liable for electrocution-related deaths. Veterinarians and veterinary pathologists called upon to diagnose and treat electrocuted birds should keep this in mind when conducting clinical and postmortem examinations. This review details necropsy findings and methods used to diagnose electrocution. A combination of gross, subgross, and radiographic examinations can aid in identification of subtle injury. Diagnosis is made based on the presence of skin and/or feather burns. Other necropsy findings may include skin lacerations, subcutaneous burns, bruising, limb avulsion, hemopericardium, and vascular rupture. At the US Fish and Wildlife Service's National Forensics Laboratory, from 2000 to 2015, 417 raptor deaths were determined to have been caused by electrocution. Bald eagles and golden eagles were the most commonly submitted species. In a retrospective review of 377 cases, for which whole bodies were submitted, 18% of the electrocuted birds had only a single, small (less than 3 cm in diameter) external burn. Small, isolated burns tended to occur on the undersides of the wings at and distal to the elbow and on the lower legs and feet. These areas should be most carefully examined in cases where electrocution injury is not immediately apparent.

  4. Developing Effective Continuous On-Line Monitoring Technologies to Manage Service Degradation of Nuclear Power Plants

    SciTech Connect

    Meyer, Ryan M.; Ramuhalli, Pradeep; Bond, Leonard J.; Cumblidge, Stephen E.

    2011-09-30

    Recently, there has been increased interest in using prognostics (i.e, remaining useful life (RUL) prediction) for managing and mitigating aging effects in service-degraded passive nuclear power reactor components. A vital part of this philosophy is the development of tools for detecting and monitoring service-induced degradation. Experience with in-service degradation has shown that rapidly-growing cracks, including several varieties of stress corrosion cracks (SCCs), can grow through a pipe in less than one fuel outage cycle after they initiate. Periodic inspection has limited effectiveness at detecting and managing such degradation requiring a more versatile monitoring philosophy. Acoustic emission testing (AET) and guided wave ultrasonic testing (GUT) are related technologies with potential for on-line monitoring applications. However, harsh operating conditions within NPPs inhibit the widespread implementation of both technologies. For AET, another hurdle is the attenuation of passive degradation signals as they travel though large components, relegating AET to targeted applications. GUT is further hindered by the complexity of GUT signatures limiting its application to the inspection of simple components. The development of sensors that are robust and inexpensive is key to expanding the use of AET and GUT for degradation monitoring in NPPs and improving overall effectiveness. Meanwhile, the effectiveness of AET and GUT in NPPs can be enhanced through thoughtful application of tandem AET-GUT techniques.

  5. Electrocution of Raptors on Power Lines: A Review of Necropsy Methods and Findings.

    PubMed

    Kagan, R A

    2016-09-01

    Decades after the problem was first identified, power line electrocution continues to be a cause of avian mortality. Currently, several federal laws protect eagles and other migratory birds, meaning that utility companies may be liable for electrocution-related deaths. Veterinarians and veterinary pathologists called upon to diagnose and treat electrocuted birds should keep this in mind when conducting clinical and postmortem examinations. This review details necropsy findings and methods used to diagnose electrocution. A combination of gross, subgross, and radiographic examinations can aid in identification of subtle injury. Diagnosis is made based on the presence of skin and/or feather burns. Other necropsy findings may include skin lacerations, subcutaneous burns, bruising, limb avulsion, hemopericardium, and vascular rupture. At the US Fish and Wildlife Service's National Forensics Laboratory, from 2000 to 2015, 417 raptor deaths were determined to have been caused by electrocution. Bald eagles and golden eagles were the most commonly submitted species. In a retrospective review of 377 cases, for which whole bodies were submitted, 18% of the electrocuted birds had only a single, small (less than 3 cm in diameter) external burn. Small, isolated burns tended to occur on the undersides of the wings at and distal to the elbow and on the lower legs and feet. These areas should be most carefully examined in cases where electrocution injury is not immediately apparent. PMID:27154543

  6. Environmental justice: a contrary finding for the case of high-voltage electric power transmission lines.

    PubMed

    Wartenberg, Daniel; Greenberg, Michael R; Harris, Gerald

    2010-05-01

    Environmental justice is the consideration of whether minority and/or lower-income residents in a geographic area are likely to have disproportionately higher exposures to environmental toxins than those living elsewhere. Such situations have been identified for a variety of factors, such as air pollution, hazardous waste, water quality, noise, residential crowding, and housing quality. This study investigates the application of this concept to high-voltage electric power transmission lines (HVTL), which some perceive as a health risk because of the magnetic fields they generate, and also as esthetically unpleasing. We mapped all 345 kV and higher voltage HVTL in New York State and extracted and summarized proximate US Census sociodemographic and housing characteristic data into four categories on the basis of distances from HVTL. Contrary to our expectation, people living within 2000 ft from HVTL were more likely to be exposed to magnetic fields, white, of higher income, more educated and home owners, than those living farther away, particularly in urban areas. Possible explanations for these patterns include the desire for the open space created by the rights-of-way, the preference for new homes/subdivisions that are often located near HVTL, and moving closer to HVTL before EMFs were considered a risk. This study suggests that environmental justice may not apply to all environmental risk factors and that one must be cautious in generalizing. In addition, it shows the utility of geographical information system methodology for summarizing information from extremely large populations, often a challenge in epidemiology.

  7. Practice and power: a review and interpretive synthesis focused on the exercise of discretionary power in policy implementation by front-line providers and managers.

    PubMed

    Gilson, Lucy; Schneider, Helen; Orgill, Marsha

    2014-12-01

    Tackling the implementation gap is a health policy concern in low- and middle-income countries (LMICs). Limited attention has so far been paid to the influence of power relations over this gap. This article presents, therefore, an interpretive synthesis of qualitative health policy articles addressing the question: how do actors at the front line of health policy implementation exercise discretionary power, with what consequences and why? The article also demonstrates the particular approach of thematic synthesis and contributes to discussion of how such work can inform future health policy research. The synthesis drew from a broader review of published research on any aspect of policy implementation in LMICs for the period 1994-2009. From an initial set of 50 articles identified as relevant to the specific review question, a sample of 16 articles were included in this review. Nine report experience around decentralization, a system-level change, and seven present experience of implementing a range of reproductive health (RH) policies (new forms of service delivery). Three reviewers were involved in a systematic process of data extraction, coding, analysis, synthesis and article writing. The review findings identify: the practices of power exercised by front-line health workers and their managers; their consequences for policy implementation and health system performance; the sources of this power and health workers' reasons for exercising power. These findings also provide the basis for an overarching synthesis of experience, highlighting the importance of actors, power relations and multiple, embedded contextual elements as dimensions of health system complexity. The significance of this synthesis lies in its insights about: the micropractices of power exercised by front-line providers; how to manage this power through local level strategies both to influence and empower providers to act in support of policy goals; and the focus and nature of future research on

  8. Effects of dietary green tea polyphenol supplementation on the health of workers exposed to high-voltage power lines.

    PubMed

    Zhang, Yang; Zhang, Dan; Zhu, Baoyu; Zhang, He; Sun, Ye; Sun, Chengxun

    2016-09-01

    Although it has been several decades since the focus on the effect of extremely low frequency electromagnetic fields (ELF-EMF) of high-voltage power lines on human health, no consistent conclusion has been drawn. The present study aimed to investigate the change in oxidative stress after exposure to ELF-EMFs, and potential protective effects of green tea polyphenol supplementation (GTPS) on ELF-EMFs induced oxidative stress. A total of 867 subjects, including workers with or without exposure to ELF-EMFs of 110-420kV power lines, participated and were randomized into GTPS and placebo treatment groups. Oxidative stress and oxidative damage to DNA were assessed by urinary tests of 8-isoprostane and 8-OHdG. Significant increased urinary 8-isoprostane and 8-OHdG were observed in workers with ELF-EMFs exposure, which were diminished after 12 months of GTPS. No protective effects of GTPS on oxidative stress and oxidative damage to DNA were observed after three months of GTPS withdraw. We found a negative impact of high-voltage power lines on the health of workers. Long-term GTPS could be an efficient protection against the health issues induced by high-voltage power lines. PMID:27490209

  9. Assessment of electromagnetic field levels from surrounding high-tension overhead power lines for proposed land use.

    PubMed

    Al-Bassam, E; Elumalai, A; Khan, A; Al-Awadi, L

    2016-05-01

    The surrounding outdoor environment for new development has a big effect on the indoor quality of life. The main aim of this work was to determine the suitability of the area for building new schools with reference to electromagnetic field (EMF) effects. The specific objective of this study was to detect the safe distance from the EMF posed by the high-tension overhead power lines in the vicinity of the specified area. The measurements were taken for both the electric and magnetic fields in different months in order to detect the highest EMF levels during the peak power load season. EMDEX II with E-probe and EMDEX II with Linda were used for the measurements. These instruments were all calibrated by ENERTECH Company in USA. The EMF associated with high tension transmission lines that surrounded the proposed site has to be below 0.2 μT (Italian EMF regulations are the most suitable regulations for the establishment of schools in Kuwait). The safety clearance distance from the existing 300-kV high-tension power line has been assigned as 200 m and from other existing 132-kV high-tension power line was 50 m. The proposed site with its predefined boundaries has a magnetic field below the Italian EMF regulations for the establishment of new schools.

  10. 29 CFR 1926.1410 - Power line safety (all voltages)-equipment operations closer than the Table A zone.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 8 2013-07-01 2013-07-01 false Power line safety (all voltages)-equipment operations... video equipment), equipped with flags or similar high-visibility markings, to prevent electrical contact... November 8, 2013, the following procedure may be substituted for the requirement in (d)(4)(i) of...

  11. Effects of dietary green tea polyphenol supplementation on the health of workers exposed to high-voltage power lines.

    PubMed

    Zhang, Yang; Zhang, Dan; Zhu, Baoyu; Zhang, He; Sun, Ye; Sun, Chengxun

    2016-09-01

    Although it has been several decades since the focus on the effect of extremely low frequency electromagnetic fields (ELF-EMF) of high-voltage power lines on human health, no consistent conclusion has been drawn. The present study aimed to investigate the change in oxidative stress after exposure to ELF-EMFs, and potential protective effects of green tea polyphenol supplementation (GTPS) on ELF-EMFs induced oxidative stress. A total of 867 subjects, including workers with or without exposure to ELF-EMFs of 110-420kV power lines, participated and were randomized into GTPS and placebo treatment groups. Oxidative stress and oxidative damage to DNA were assessed by urinary tests of 8-isoprostane and 8-OHdG. Significant increased urinary 8-isoprostane and 8-OHdG were observed in workers with ELF-EMFs exposure, which were diminished after 12 months of GTPS. No protective effects of GTPS on oxidative stress and oxidative damage to DNA were observed after three months of GTPS withdraw. We found a negative impact of high-voltage power lines on the health of workers. Long-term GTPS could be an efficient protection against the health issues induced by high-voltage power lines.

  12. 77 FR 41369 - Dairyland Power Cooperative: CapX 2020 Hampton-Rochester-La Crosse Transmission Line Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... Rural Utilities Service Dairyland Power Cooperative: CapX 2020 Hampton-Rochester-La Crosse Transmission Line Project AGENCY: Rural Utilities Service, USDA. ACTION: Notice of Availability of a Final Environmental Impact Statement. SUMMARY: Notice is hereby given that the Rural Utilities Service (RUS)...

  13. High-Harmonic Fast-Wave Power Flow Along Magnetic Field Lines in the Scrape-Off Layer of NSTX

    SciTech Connect

    Perkins, R. J.; Hosea, J.; Kramer, G.; Ahn, Joonwook; Bell, R. E.; Diallo, A.; Gerhardt, S.; Gray, T. K.; Green, David L; Jaeger, Erwin Frederick; Jaworski, M. A.; LeBlanc, B; McLean, Adam G; Maingi, Rajesh; Phillips, C. K.; Roquemore, L.; Ryan, Philip Michael; Sabbagh, S. A.; Taylor, G.; Wilson, J. R.

    2012-01-01

    A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast-wave heating and current drive.

  14. High-harmonic fast-wave power flow along magnetic field lines in the scrape-off layer of NSTX.

    PubMed

    Perkins, R J; Hosea, J C; Kramer, G J; Ahn, J-W; Bell, R E; Diallo, A; Gerhardt, S; Gray, T K; Green, D L; Jaeger, E F; Jaworski, M A; LeBlanc, B P; McLean, A; Maingi, R; Phillips, C K; Roquemore, L; Ryan, P M; Sabbagh, S; Taylor, G; Wilson, J R

    2012-07-27

    A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast-wave heating and current drive.

  15. Cryogenic-temperature profiling of high-power superconducting lines using local and distributed optical-fiber sensors.

    PubMed

    Chiuchiolo, Antonella; Palmieri, Luca; Consales, Marco; Giordano, Michele; Borriello, Anna; Bajas, Hugues; Galtarossa, Andrea; Bajko, Marta; Cusano, Andrea

    2015-10-01

    This contribution presents distributed and multipoint fiber-optic monitoring of cryogenic temperatures along a superconducting power transmission line down to 30 K and over 20 m distance. Multipoint measurements were conducted using fiber Bragg gratings sensors coated with two different functional overlays (epoxy and poly methyl methacrylate (PMMA)) demonstrating cryogenic operation in the range 300-4.2 K. Distributed measurements exploited optical frequency-domain reflectometry to analyze the Rayleigh scattering along two concatenated fibers with different coatings (acrylate and polyimide). The integrated system has been placed along the 20 m long cryostat of a superconducting power transmission line, which is currently being tested at the European Organization for Nuclear Research (CERN). Cool-down events from 300-30 K have been successfully measured in space and time, confirming the viability of these approaches to the monitoring of cryogenic temperatures along a superconducting transmission line. PMID:26421547

  16. Effect of hepatitis B virus infection on trophoblast cell line (HTR-8/SVneo) and choriocarcinoma cell line (JEG3) is linked to CD133-2 (AC141) expression.

    PubMed

    Cui, Hong; Chen, Jing; Na, Quan

    2016-01-01

    Mother-to-infant transmission of hepatitis B virus (HBV) plays an important role in the chronic carrier state in China. In our studies, the response of trophoblast cell and choriocarcinoma cell to HBV infection regarding the expression of CD133-2 (AC141) was evaluated. Western blot and RT-PCR showed that a high level of CD133-2 protein and mRNA in HTR-8/SVneo cells, but a low level in JEG-3 cells. Lower proliferation and mobility, and higher apoptosis were observed in HTR-8/SVneo cells and JEG-3-CD133-2(+) cells after HBV infection than those in HTR-8-CD133-2(-) cells and JEG-3 cells. Our main finding is that CD133-negative cells (HTR-8-CD133-2(-) and JEG-3) are prone to HBV infection. In the last, our data indicated that the activation of Smad signaling pathway and the induction of epithelial-mesenchymal transition (EMT) in CD133-negative cells after HBV infection. In summary, our study demonstrated that CD133 is a key factor that mediated HBV infection to trophoblast cell and choriocarcinoma cell. PMID:27508045

  17. Power flow controller with a fractionally rated back-to-back converter

    DOEpatents

    Divan, Deepakraj M.; Kandula, Rajendra Prasad; Prasai, Anish

    2016-03-08

    A power flow controller with a fractionally rated back-to-back (BTB) converter is provided. The power flow controller provide dynamic control of both active and reactive power of a power system. The power flow controller inserts a voltage with controllable magnitude and phase between two AC sources at the same frequency; thereby effecting control of active and reactive power flows between the two AC sources. A transformer may be augmented with a fractionally rated bi-directional Back to Back (BTB) converter. The fractionally rated BTB converter comprises a transformer side converter (TSC), a direct-current (DC) link, and a line side converter (LSC). By controlling the switches of the BTB converter, the effective phase angle between the two AC source voltages may be regulated, and the amplitude of the voltage inserted by the power flow controller may be adjusted with respect to the AC source voltages.

  18. Metallicities of Emission-Line Galaxies from HST ACS PEARS and HST WFC3 ERS Grism Spectroscopy at 0.6 is less than z is less than 2.4

    NASA Technical Reports Server (NTRS)

    Xia, Lifang; Malhotra, Sangetta; Rhoads, James; Pirzkal, Nor; Straughn, Amber; Finkelstein, Steven; Cohen, Seth; Kuntschner, Harald; Walsh, Jeremy; Windhorst, Rogier A.; O'Connell, Robert; Kuemmel, Martin

    2012-01-01

    Galaxies selected on the basis of their emission line strength. show low metallicities, regardless of their redshifts. We conclude this from a sample of faint galaxies at redshifts between 0.6 < z < 2.4, selected by their prominent emission lines in low resolution grism spectra in the optiCa.i with the Advanced Camera for Surveys (ACS) on the Hubble Space Telescope (HST) and in the near-infrared using Wide-Field Camera 3 (WFC3). Using a sample of 11 emission line galaxies (ELGs) at 0.6 < z < 2.4 with luminosities of -22 approx < MB approx -19 which have [OII], H-Beta, and [OIII] line flux measurements from the combination of two grism spectral surveys, we use the R23 method to derive the gas-phase oxygen abundances: 7.5 <12+log(0/H)<8.5. The galaxy stellar masses are derived using Bayesian based Markov Chain Monte Carlo (pi MC(exp 2)) fitting of their Spectral Energy Distribution (SED), and span the mass range 8.1 < log(M(stellar)/M(solar)) < 10.1. These galaxies show a mass-metal1icity (M-L) and Luminosity-Metallicity (LZ) relation, which is offset by -line selected galaxies most resemble the local "green peas" galaxies and Lyman-alpha galaxies at z approx = 0.3 and z approx = 2.3 in the M-Z and L-Z relations and their morphologies. The G - M(sub 20) morphology analysis shows that 10 out of 11 show disturbed morphology, even as the star-forming regions are compact. These galaxies may be intrinsically metal poor, being at early stages of formation, or the low metallicities may be due to gas infall and accretion due to mergers.

  19. Environmental justice: a contrary finding for the case of high-voltage electric power transmission lines.

    PubMed

    Wartenberg, Daniel; Greenberg, Michael R; Harris, Gerald

    2010-05-01

    Environmental justice is the consideration of whether minority and/or lower-income residents in a geographic area are likely to have disproportionately higher exposures to environmental toxins than those living elsewhere. Such situations have been identified for a variety of factors, such as air pollution, hazardous waste, water quality, noise, residential crowding, and housing quality. This study investigates the application of this concept to high-voltage electric power transmission lines (HVTL), which some perceive as a health risk because of the magnetic fields they generate, and also as esthetically unpleasing. We mapped all 345 kV and higher voltage HVTL in New York State and extracted and summarized proximate US Census sociodemographic and housing characteristic data into four categories on the basis of distances from HVTL. Contrary to our expectation, people living within 2000 ft from HVTL were more likely to be exposed to magnetic fields, white, of higher income, more educated and home owners, than those living farther away, particularly in urban areas. Possible explanations for these patterns include the desire for the open space created by the rights-of-way, the preference for new homes/subdivisions that are often located near HVTL, and moving closer to HVTL before EMFs were considered a risk. This study suggests that environmental justice may not apply to all environmental risk factors and that one must be cautious in generalizing. In addition, it shows the utility of geographical information system methodology for summarizing information from extremely large populations, often a challenge in epidemiology. PMID:19352413

  20. Radiological Assessment for the Removal of Legacy BPA Power Lines that Cross the Hanford Site

    SciTech Connect

    Millsap, William J.; Brush, Daniel J.

    2013-11-13

    This paper discusses some radiological field monitoring and assessment methods used to assess the components of an old electrical power transmission line that ran across the Hanford Site between the production reactors area (100 Area) and the chemical processing area (200 Area). This task was complicated by the presence of radon daughters -- both beta and alpha emitters -- residing on the surfaces, particularly on the surfaces of weathered metals and metals that had been electrically-charged. In many cases, these activities were high compared to the DOE Surface Contamination Guidelines, which were used as guides for the assessment. These methods included the use of the Toulmin model of argument, represented using Toulmin diagrams, to represent the combined force of several strands of evidences, rather than a single measurement of activity, to demonstrate beyond a reasonable doubt that no or very little Hanford activity was present and mixed with the natural activity. A number of forms of evidence were used: the overall chance of Hanford contamination; measurements of removable activity, beta and alpha; 1-minute scaler counts of total surface activity, beta and alpha, using "background makers"; the beta activity to alpha activity ratios; measured contamination on nearby components; NaI gamma spectral measurements to compare uncontaminated and potentially-contaminated spectra, as well as measurements for the sentinel radionuclides, Am- 241 and Cs-137 on conducting wire; comparative statistical analyses; and in-situ measurements of alpha spectra on conducting wire showing that the alpha activity was natural Po-210, as well as to compare uncontaminated and potentially-contaminated spectra.

  1. Digital ac monitor

    DOEpatents

    Hart, G.W.; Kern, E.C. Jr.

    1987-06-09

    An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer. 24 figs.

  2. Digital ac monitor

    DOEpatents

    Hart, George W.; Kern, Jr., Edward C.

    1987-06-09

    An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer.

  3. Terawatt power division and combination using self-magnetically insulated transmission lines

    SciTech Connect

    Crow, J.T.; Peterson, G.D.

    1980-01-01

    Self-magnetically insulated transmission lines are necessary for the efficient transport of the terawatt pulses used in electron and ion accelerators. For some applications it is desirable to divide one transmission line into two, or to combine outputs of two or more lines into one, by means of self-magnetically insulated convolutes. Tests have been made on a coaxial-to-triaxial convolute in which connections between negative inner and outer lines are made by pins passing through holes in the intermediate positive conductor. Measurements in the 2 MV, 400 kA, 40 ns pulse Mite facility indicate virtually 100% current transport through the convolute and the ability to vary the division of current between the inner and outer lines of the triax by choice of inner line impedance. These measurements, and results obtained with this convolute connected to the ion diode for which it was designed, will be presented.

  4. Application of fiber-optic bragg grating sensors in monitoring environmental loads of overhead power transmission lines.

    PubMed

    Bjerkan, L

    2000-02-01

    We demonstrate the capability of using fiber-optic sensors for measurements on environmental loads on a high-power, overhead transmission line. A trial system with three Bragg gratings, including a temperature reference, was installed on a 160-m span of a 60-kV line. An interrogation system with a tunable distributed Bragg reflector laser source was used. Several measurements of the induced loads on a conductor were recorded in various wind conditions. In particular, aeolian vibrations were frequently observed, and several measurements of this phenomenon were made. The results correlate well with simple theoretical predictions and visual observations.

  5. Power-law index and penetration depth of (NdxSmxGd1-2x)Ba2Cu3O7-δ films studied by AC susceptibility

    NASA Astrophysics Data System (ADS)

    Li, Xiao-Fen; He, Dong; Grivel, Jean-Claude

    2012-12-01

    Superconducting (NdxSmxGd1-2x)Ba2Cu3O7-δ films with x=0, 0.1, 0.25, 0.33 were grown by PLD on STO single crystal substrates. The power-law index n and penetration depth λ are studied by AC susceptibility. During cooling, n in films with x ≠ 0 increases much slower compared with the films with x = 0. The films with x ≠ 0 also tend to have a longer penetration depth. These properties might be related to the higher possibility for disorder in the mixed (Nd,Sm,Gd)BCO films.

  6. Issues concerning centralized versus decentralized power deployment

    NASA Technical Reports Server (NTRS)

    Metcalf, Kenneth J.; Harty, Richard B.; Robin, James F.

    1991-01-01

    The results of a study of proposed lunar base architectures to identify issues concerning centralized and decentralized power system deployment options are presented. The power system consists of the energy producing system (power plant), the power conditioning components used to convert the generated power into the form desired for transmission, the transmission lines that conduct this power from the power sources to the loads, and the primary power conditioning hardware located at the user end. Three power system architectures, centralized, hybrid, and decentralized, were evaluated during the course of this study. Candidate power sources were characterized with respect to mass and radiator area. Two electrical models were created for each architecture to identify the preferred method of power transmission, dc or ac. Each model allowed the transmission voltage level to be varied at assess the impact on power system mass. The ac power system models also permitted the transmission line configurations and placements to determine the best conductor construction and installation location. Key parameters used to evaluate each configuration were power source and power conditioning component efficiencies, masses, and radiator areas; transmission line masses and operating temperatures; and total system mass.

  7. Fast-wave Power Flow Along SOL Field Lines In NSTX nd The Associated Power Deposition Profile Across The SOL In Front Of The Antenna

    SciTech Connect

    Perkins, Roy

    2013-06-21

    Fast-wave heating and current drive efficiencies can be reduced by a number of processes in the vicinity of the antenna and in the scrape off layer (SOL). On NSTX from around 25% to more than 60% of the high-harmonic fast-wave power can be lost to the SOL regions, and a large part of this lost power flows along SOL magnetic field lines and is deposited in bright spirals on the divertor floor and ceiling. We show that field-line mapping matches the location of heat deposition on the lower divertor, albeit with a portion of the heat outside of the predictions. The field-line mapping can then be used to partially reconstruct the profile of lost fast-wave power at the midplane in front of the antenna, and the losses peak close to the last closed flux surface (LCFS) as well as the antenna. This profile suggests a radial standing-wave pattern formed by fast-wave propagation in the SOL, and this hypothesis will be tested on NSTX-U. Advanced RF codes must reproduce these results so that such codes can be used to understand this edge loss and to minimize RF heat deposition and erosion in the divertor region on ITER.

  8. 33 CFR 222.3 - Clearances for power and communication lines over reservoirs.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... clearances required over navigable waters are covered by 33 CFR 322.5(i)(2) and are not affected by this... communication lines over reservoirs. 222.3 Section 222.3 Navigation and Navigable Waters CORPS OF ENGINEERS... communication lines over reservoirs. (a) Purpose. This regulation prescribes the minimum vertical clearances...

  9. Power Line Noise in Transient Electromagnetic (TEM) Data: Identification and Removal in a Practical Field Study.

    NASA Astrophysics Data System (ADS)

    Jernsletten, J. A.

    2004-05-01

    INTRODUCTION: To evaluate the appropriateness of TEM in mapping deep groundwater tables (in Mars analog environmnets), a field study was carried out in the desert ~30 miles SW of Tucson, Arizona. The study was also designed to observe effects of powerline noise on TEM data. The clay-rich soil in the area is quite conductive. The study consisted of 40 in-loop TEM stations, divided into 3 lines, for 4 line-km of data. The survey was carried out by a crew of one person, with square Tx wire loops 100 m on a side, and a ferrite-core magnetic coil Rx antenna in the center of each Tx loop. Maximum useful depth of investigation achieved was ~600 m. TEM DATA: The field area is surrounded by powerlines on all 4 sides: Line 1 has the outside of the first Tx loop under the powerline to the West; Line 2 starts with the powerline to the North passing above just inside its first Tx loop, and ends with the outside of the last station's transmitter loop ~20 m shy of the powerline to the South; finally, Line 3 starts ~50 m East of the powerline to the West, and runs parallel to the powerline to the South along its entire length, at a separation distance of ~70 m. Line 3 was placed largely in an effort to obeserve powerline noise. The decay curve for the first station on Line 1(Line 1/Station 50) is raised above the other curves from Line 1. This is due to the charge (noise) from the adjacent powerline, which is at a distance of ~50 m from the Rx coil. In effect, the transient decay is recorded as being slower than it would be without the presence of the powerline. This also artficially lowers the apparent resistivity, readily observed in Line 1/Station 50 data. These effects are present to a lesser extent (lower magnitude noise) in the data from Line1/Station 150, the second station on Line 1. On the smooth-model inversion cross-section of the data from Line 1, the effects of the powerline noise appears as a pulling up of the low-resistivity water table contact towards the surface

  10. Power transmission cable development for the Space Station Freedom electrical power system

    NASA Technical Reports Server (NTRS)

    Schmitz, Gregory V.; Biess, John J.

    1989-01-01

    Power transmission cable is presently being evaluated under a NASA Lewis Research Center advanced development contract for application in the Space Station Freedom (SSF) electrical power system (EPS). Evaluation testing has been performed by TRW and NASA Lewis Research Center. The results of this development contract are presented. The primary cable design goals are to provide (1) a low characteristic inductance to minimize line voltage drop at 20 kHz, (2) electromagnetic compatibility control of the 20-kHz ac power current, (3) a physical configuration that minimizes ac resistance and (4) release of trapped air for corona-free operation.

  11. Centaur feedline dynamics study using power spectral methods. [fundamental mode resonant frequencies of RL-10 oxygen and hydrogen feed lines

    NASA Technical Reports Server (NTRS)

    Lorenzo, C. F.

    1974-01-01

    Tests were conducted to determine the dynamic characteristics of the Centaur/RL-10 oxygen and hydrogen feedlines. The fundamental-mode resonant frequencies were determined by applying power spectral methods to noise-generated data from hot firings of the RL-10 engine. The effect of net positive suction pressure of the main feed pumps on resonant frequency characteristics was determined to be a straight-line relation. Power spectral methods were also used to determine the dynamic characteristics of the boost pumps.

  12. THROUGH-THE-EARTH (TTE) COMMUNICATIONS SYSTEM AND THE IN-MINE POWER LINE (IMPL) COMMUNICATIONS SYSTEM

    SciTech Connect

    Zvi H. Meiksin

    2002-01-01

    Work has progressed on both subsystems: the Through-the-Earth (TTE) Communications system and the In-Mine Power Line (IMPL) Communications system. The TTE system: The system was fabricated and repackaged as an industrial product enclosed in a commercial rugged, waterproof housing suitable for installation in mines. Features were added to the system to appeal to the preferences of different mine managers. Arrangements were made with NIOSH to install the system in the Lake Lynn underground mine for evaluation and demonstration to potential users. The IMPL system: Voice compression was successfully implemented and incorporated into the laboratory model. Compressed voice was transmitted through a power line, expanded at the receiving end, and received with high clarity.

  13. Numerical investigation of the physical model of a high-power electromagnetic wave in a magnetically insulated transmission line

    SciTech Connect

    Samokhin, A. A.

    2010-02-15

    An efficient numerical code for simulating the propagation of a high-power electromagnetic pulse in a vacuum transmission line is required to study the physical phenomena occurring in such a line, to analyze the operation of present-day megavolt generators at an {approx}10-TW power level, and to design such new devices. The main physical theoretical principles are presented, and the stability of flows in the near-threshold region at the boundary of the regime of magnetic self-insulation is investigated based on one-dimensional telegraph equations with electron losses. Numerical (difference) methods-specifically, a method of characteristics and a finite-difference scheme-are described and their properties and effectiveness are compared by analyzing the high-frequency modes.

  14. Long-range response in ac electricity grids.

    PubMed

    Jung, Daniel; Kettemann, Stefan

    2016-07-01

    Local changes in the topology of electricity grids can cause overloads far away from the disturbance [D. Witthaut and M. Timme, Eur. Phys. J. B 86, 377 (2013)EPJBFY1434-602810.1140/epjb/e2013-40469-4], making the prediction of the robustness against changes in the topology-for example, caused by power outages or grid extensions-a challenging task. The impact of single-line additions on the long-range response of dc electricity grids has recently been studied [D. Labavić, R. Suciu, H. Meyer-Ortmanns, and S. Kettemann, Eur. Phys. J.: Spec. Top. 223, 2517 (2014)1951-635510.1140/epjst/e2014-02273-0]. By solving the real part of the static ac load flow equations, we conduct a similar investigation for ac grids. In a regular two-dimensional grid graph with cyclic boundary conditions, we find a power law decay for the change of power flow as a function of distance to the disturbance over a wide range of distances. The power exponent increases and saturates for large system sizes. By applying the same analysis to the German transmission grid topology, we show that also in real-world topologies a long-ranged response can be found. PMID:27575148

  15. Long-range response in ac electricity grids

    NASA Astrophysics Data System (ADS)

    Jung, Daniel; Kettemann, Stefan

    2016-07-01

    Local changes in the topology of electricity grids can cause overloads far away from the disturbance [D. Witthaut and M. Timme, Eur. Phys. J. B 86, 377 (2013), 10.1140/epjb/e2013-40469-4], making the prediction of the robustness against changes in the topology—for example, caused by power outages or grid extensions—a challenging task. The impact of single-line additions on the long-range response of dc electricity grids has recently been studied [D. Labavić, R. Suciu, H. Meyer-Ortmanns, and S. Kettemann, Eur. Phys. J.: Spec. Top. 223, 2517 (2014), 10.1140/epjst/e2014-02273-0]. By solving the real part of the static ac load flow equations, we conduct a similar investigation for ac grids. In a regular two-dimensional grid graph with cyclic boundary conditions, we find a power law decay for the change of power flow as a function of distance to the disturbance over a wide range of distances. The power exponent increases and saturates for large system sizes. By applying the same analysis to the German transmission grid topology, we show that also in real-world topologies a long-ranged response can be found.

  16. Long-range response in ac electricity grids.

    PubMed

    Jung, Daniel; Kettemann, Stefan

    2016-07-01

    Local changes in the topology of electricity grids can cause overloads far away from the disturbance [D. Witthaut and M. Timme, Eur. Phys. J. B 86, 377 (2013)EPJBFY1434-602810.1140/epjb/e2013-40469-4], making the prediction of the robustness against changes in the topology-for example, caused by power outages or grid extensions-a challenging task. The impact of single-line additions on the long-range response of dc electricity grids has recently been studied [D. Labavić, R. Suciu, H. Meyer-Ortmanns, and S. Kettemann, Eur. Phys. J.: Spec. Top. 223, 2517 (2014)1951-635510.1140/epjst/e2014-02273-0]. By solving the real part of the static ac load flow equations, we conduct a similar investigation for ac grids. In a regular two-dimensional grid graph with cyclic boundary conditions, we find a power law decay for the change of power flow as a function of distance to the disturbance over a wide range of distances. The power exponent increases and saturates for large system sizes. By applying the same analysis to the German transmission grid topology, we show that also in real-world topologies a long-ranged response can be found.

  17. Number of lightning discharges causing damage to lightning arrester cables for aerial transmission lines in power systems

    SciTech Connect

    Nikiforov, E. P.

    2009-07-15

    Damage by lightning discharges to lightning arrester cables for 110-175 kV aerial transmission lines is analyzed using data from power systems on incidents with aerial transmission lines over a ten year operating period (1997-2006). It is found that failures of lightning arrester cables occur when a tensile force acts on a cable heated to the melting point by a lightning current. The lightning currents required to heat a cable to this extent are greater for larger cable cross sections. The probability that a lightning discharge will develop decreases as the amplitude of the lightning current increases, which greatly reduces the number of lightning discharges which damage TK-70 cables compared to TK-50 cables. In order to increase the reliability of lightning arrester cables for 110 kV aerial transmission lines, TK-70 cables should be used in place of TK-50 cables. The number of lightning discharges per year which damage lightning arrester cables is lowered when the density of aerial transmission lines is reduced within the territory of electrical power systems. An approximate relationship between these two parameters is obtained.

  18. Urban Power Line Corridors as Novel Habitats for Grassland and Alien Plant Species in South-Western Finland.

    PubMed

    Lampinen, Jussi; Ruokolainen, Kalle; Huhta, Ari-Pekka

    2015-01-01

    Regularly managed electric power line corridors may provide habitats for both early-successional grassland plant species and disturbance-dependent alien plant species. These habitats are especially important in urban areas, where they can help conserve native grassland species and communities in urban greenspace. However, they can also provide further footholds for potentially invasive alien species that already characterize urban areas. In order to implement power line corridors into urban conservation, it is important to understand which environmental conditions in the corridors favor grassland species and which alien species. Likewise it is important to know whether similar environmental factors in the corridors control the species composition of the two groups. We conducted a vegetation study in a 43 kilometer long urban power line corridor network in south-western Finland, and used generalized linear models and distance-based redundancy analysis to determine which environmental factors best predict the occurrence and composition of grassland and alien plant species in the corridors. The results imply that old corridors on dry soils and steep slopes characterized by a history as open areas and pastures are especially suitable for grassland species. Corridors suitable for alien species, in turn, are characterized by productive soils and abundant light and are surrounded by a dense urban fabric. Factors controlling species composition in the two groups are somewhat correlated, with the most important factors including light abundance, soil moisture, soil calcium concentration and soil productivity. The results have implications for grassland conservation and invasive alien species control in urban areas.

  19. Urban Power Line Corridors as Novel Habitats for Grassland and Alien Plant Species in South-Western Finland.

    PubMed

    Lampinen, Jussi; Ruokolainen, Kalle; Huhta, Ari-Pekka

    2015-01-01

    Regularly managed electric power line corridors may provide habitats for both early-successional grassland plant species and disturbance-dependent alien plant species. These habitats are especially important in urban areas, where they can help conserve native grassland species and communities in urban greenspace. However, they can also provide further footholds for potentially invasive alien species that already characterize urban areas. In order to implement power line corridors into urban conservation, it is important to understand which environmental conditions in the corridors favor grassland species and which alien species. Likewise it is important to know whether similar environmental factors in the corridors control the species composition of the two groups. We conducted a vegetation study in a 43 kilometer long urban power line corridor network in south-western Finland, and used generalized linear models and distance-based redundancy analysis to determine which environmental factors best predict the occurrence and composition of grassland and alien plant species in the corridors. The results imply that old corridors on dry soils and steep slopes characterized by a history as open areas and pastures are especially suitable for grassland species. Corridors suitable for alien species, in turn, are characterized by productive soils and abundant light and are surrounded by a dense urban fabric. Factors controlling species composition in the two groups are somewhat correlated, with the most important factors including light abundance, soil moisture, soil calcium concentration and soil productivity. The results have implications for grassland conservation and invasive alien species control in urban areas. PMID:26565700

  20. Urban Power Line Corridors as Novel Habitats for Grassland and Alien Plant Species in South-Western Finland

    PubMed Central

    Lampinen, Jussi; Ruokolainen, Kalle; Huhta, Ari-Pekka

    2015-01-01

    Regularly managed electric power line corridors may provide habitats for both early-successional grassland plant species and disturbance-dependent alien plant species. These habitats are especially important in urban areas, where they can help conserve native grassland species and communities in urban greenspace. However, they can also provide further footholds for potentially invasive alien species that already characterize urban areas. In order to implement power line corridors into urban conservation, it is important to understand which environmental conditions in the corridors favor grassland species and which alien species. Likewise it is important to know whether similar environmental factors in the corridors control the species composition of the two groups. We conducted a vegetation study in a 43 kilometer long urban power line corridor network in south-western Finland, and used generalized linear models and distance-based redundancy analysis to determine which environmental factors best predict the occurrence and composition of grassland and alien plant species in the corridors. The results imply that old corridors on dry soils and steep slopes characterized by a history as open areas and pastures are especially suitable for grassland species. Corridors suitable for alien species, in turn, are characterized by productive soils and abundant light and are surrounded by a dense urban fabric. Factors controlling species composition in the two groups are somewhat correlated, with the most important factors including light abundance, soil moisture, soil calcium concentration and soil productivity. The results have implications for grassland conservation and invasive alien species control in urban areas. PMID:26565700

  1. Development of An On-Line, Core Power Distribution Monitoring System

    SciTech Connect

    Tunc ALdemir; Don Miller; Peng Wang

    2007-10-02

    The objective of the proposed work was to develop a software package that can construct in three-dimensional core power distributions using the signals from constant temperature power sensors distributed in the reactor core. The software developed uses a mode-based state/parameter estmation technique that is particularly attractive when there are model uncertainties and/or large signal noise. The software yields the expected value of local power at the detector locations and points in between, as well as the probability distribution of the local power density

  2. Experiments with Uas Imagery for Automatic Modeling of Power Line 3d Geometry

    NASA Astrophysics Data System (ADS)

    Jóźków, G.; Vander Jagt, B.; Toth, C.

    2015-08-01

    The ideal mapping technology for transmission line inspection is the airborne LiDAR executed from helicopter platforms. It allows for full 3D geometry extraction in highly automated manner. Large scale aerial images can be also used for this purpose, however, automation is possible only for finding transmission line positions (2D geometry), and the sag needs to be estimated manually. For longer lines, these techniques are less expensive than ground surveys, yet they are still expensive. UAS technology has the potential to reduce these costs, especially if using inexpensive platforms with consumer grade cameras. This study investigates the potential of using high resolution UAS imagery for automatic modeling of transmission line 3D geometry. The key point of this experiment was to employ dense matching algorithms to appropriately acquired UAS images to have points created also on wires. This allowed to model the 3D geometry of transmission lines similarly to LiDAR acquired point clouds. Results showed that the transmission line modeling is possible with a high internal accuracy for both, horizontal and vertical directions, even when wires were represented by a partial (sparse) point cloud.

  3. Design concepts for a pulse power test facility to simulate EMP surges in overhead power lines. Part I. Fast pulse

    SciTech Connect

    Ramrus, A.

    1986-02-01

    Objective of the study was to create conceptual designs of high voltage pulsers capable of simulating two types of electromagnetic pulses (EMPs) caused by a high-altitude nuclear burst; the slow rise time magnetohydrodynamic (MHD-EMP) and the fast rise time high-altitude EMP (HEMP). The pulser design was directed towards facilities capable of performing EMP vulnerability testing of components used in the national electric power system.

  4. The AC-120: The advanced commercial transport

    NASA Technical Reports Server (NTRS)

    Duran, David; Griffin, Ernest; Mendoza, Saul; Nguyen, Son; Pickett, Tim; Noernberg, Clemm

    1993-01-01

    The main objective of this design was to fulfill a need for a new airplane to replace the aging 100 to 150 passenger, 1500 nautical mile range aircraft such as the Douglas DC9 and Boeing 737-100 airplanes. After researching the future aircraft market, conducting extensive trade studies, and analysis on different configurations, the AC-120 Advanced Commercial Transport final design was achieved. The AC-120's main design features include the incorporation of a three lifting surface configuration which is powered by two turboprop engines. The AC-120 is an economically sensitive aircraft which meets the new FM Stage Three noise requirements, and has lower NO(x) emissions than current turbofan powered airplanes. The AC-120 also improves on its contemporaries in passenger comfort, manufacturing, and operating cost.

  5. On the relation between power and astigmatism near an umbilic line.

    PubMed

    Rubinstein, Jacob

    2011-05-01

    The relation between the variation of power and astigmatism in a progressive power optical element is considered. The classical Minkwitz identity is revisited. Then, it is shown how to extend this identity, which applies to the geometry of surfaces, to optical parameters that are determined by the geometry of reflected or refracted wavefronts. PMID:21532682

  6. High-power electromagnetic wave in a magnetically insulated transmission line of the ANGARA-5-1 facility

    SciTech Connect

    Samokhin, A. A.

    2010-08-15

    Studies of physical phenomena in magnetically insulated transmission lines (MITLs) of high-power pulsed current generators, analysis of operation of existing megavolt generators, and designing of new high-current generators with a power of up to {approx}10 TW require creating an efficient numerical code for modeling the propagation of a high-power electromagnetic pulse in an MITL. This paper presents basic theoretical concepts of MITL operation in the framework of telegraph equations with allowance for electron leakage and variations in the electrode emissivity and analyzes propagation of an electromagnetic wave in the MITLs of the ANGARA-5-1 eight-module facility toward a dynamic load installed in the central unit with a matrix inductance.

  7. Health responses to a new high-voltage power line route: design of a quasi-experimental prospective field study in the Netherlands

    PubMed Central

    2014-01-01

    Background New high-voltage power transmission lines will be introduced due to increasing demand for reliable and renewable energy supplies. Some residents associate non-specific health complaints with exposure to electromagnetic fields from nearby power lines. This study protocol describes the design and rationale of a prospective study investigating whether the introduction of a new power line triggers health responses in residents living nearby. Methods/Design The study is designed as a quasi-experimental field study with two pretests during the construction of a new power line route, and two posttests after it has been put into operation. Key outcomes are self-reported non-specific somatic and cognitive health complaints, and attribution of these health complaints to a power line. The main determinant is proximity to the new power line route. One member of every household (n = 2379) residing in close proximity (0-500 meters) to the overhead parts of a new power line route in the Netherlands is invited to participate, as well as a sample of household members (n = 2382) residing farther away (500-2000 meters). Multilevel analysis will be employed to test whether an increase in key outcome measures is related to proximity to the line. Longitudinal structural equation models will be applied to test to what extent health responses are mediated by psychosocial health mechanisms and moderated by negative oriented personality traits. Discussion This is the first study to investigate health responses to a new power line route in a prospective manner. The results will provide theoretical insight into psychosocial mechanisms operating during the introduction of an environmental health risk, and may offer suggestions to policymakers and other stakeholders for minimizing adverse health responses when introducing new high-voltage power lines. PMID:24606914

  8. ACS: ALMA Common Software

    NASA Astrophysics Data System (ADS)

    Chiozzi, Gianluca; Šekoranja, Matej

    2013-02-01

    ALMA Common Software (ACS) provides a software infrastructure common to all ALMA partners and consists of a documented collection of common patterns and components which implement those patterns. The heart of ACS is based on a distributed Component-Container model, with ACS Components implemented as CORBA objects in any of the supported programming languages. ACS provides common CORBA-based services such as logging, error and alarm management, configuration database and lifecycle management. Although designed for ALMA, ACS can and is being used in other control systems and distributed software projects, since it implements proven design patterns using state of the art, reliable technology. It also allows, through the use of well-known standard constructs and components, that other team members whom are not authors of ACS easily understand the architecture of software modules, making maintenance affordable even on a very large project.

  9. Optical sensing in high voltage transmission lines using power over fiber and free space optics

    NASA Astrophysics Data System (ADS)

    Rosolem, João Batista; Bassan, Fabio Renato; Penze, Rivael Strobel; Leonardi, Ariovaldo Antonio; Fracarolli, João Paulo Vicentini; Floridia, Claudio

    2015-12-01

    In this work we propose the use of power over fiber (PoF) and free space optics (FSO) techniques to powering and receive signals from an electrical current sensor placed at high voltage potential using a pair of optical collimators. The technique evaluation was performed in a laboratorial prototype using 62.5/125 μm multimode fiber to study the sensitivity of the optical alignment and the influence of the collimation process in the sensing system wavelengths: data communication (1310 nm) and powering (830 nm). The collimators were installed in a rigid electric insulator in order to maintain the stability of transmission.

  10. Electric and magnetic field exposures for people living near a 735-Kilovolt power line

    SciTech Connect

    Levallois, P.; Gauvin, D.; St. Laurent, J.

    1995-09-01

    The purpose of this study was to assess the effect of a 735-kV transmission line on the electric and magnetic field exposures of people living at the edge of the line`s right of way. Exposure of 18 adults, mostly white-collar workers, living in different bungalows located 190-240 feet from the line (exposed subjects) was compared to that of 17 adults living in similar residences far away from any transmission line. Each subject carried a Positron meter for 24 hr during 1 workday, which measured 60-Hz electric and magnetic fields every minute. All measurements were carried out in parallel for exposed and unexposed subjects during the same weeks between September and December. During measurements the average loading on the line varied between 600 and 1100 A. The average magnetic field intensity while at home was 4.4 times higher among exposed subjects than unexposed (7.1 versus 1.6 Mg, p=0.0001) and 6.2 times higher when considering only the sleeping period (6.8 versus 1.1 mG, p=0.0001). Based on the 24-hr measurement, average magnetic field exposure was three times higher among the exposed was positively correlated with the loading on the line (r=0.8, p+0.001). Percentage of time above a magnetic field threshold F(2 mG or 7.8 mG) was a good indicator to distinguish the two types of exposure. Percentage of time above 20 V/m was significantly different, but percentage of time above 78 V/m was rare and comparable for the two groups. Variability of exposure was very low. This study demonstrates that a 735-kV line contributes significantly to residential 60-Hz magnetic field exposure and, to a lesser extent, electric fields for people living at the edge of the right way. Because of the limited size of our sample, caution is recommended before generalizing these results. Nevertheless, due to the uncertainty on the risks associated with such an unusual high residential exposure, research is needed on its possible effects. 30 refs., 1 fig., 7 tabs.

  11. A novel high-density power energy harvesting methodology for transmission line online monitoring devices

    NASA Astrophysics Data System (ADS)

    Liu, Yadong; Xie, Xiaolei; Hu, Yue; Qian, Yong; Sheng, Gehao; Jiang, Xiuchen; Liu, Yilu

    2016-07-01

    This paper presents a novel energy-harvesting model which takes the primary current, secondary turns, dimension, the magnitude of magnetic flux density B, and the core loss resistance into consideration systematically. The relationship among the potential maximum output power, the dimension of energy harvesting coil (EHC), the load type of EHC, and the secondary turns is predicted by theoretical analysis and further verified by experiments. A high power density harvester is also developed and tested. It is shown that the power density of this novel harvester is 0.7 mW/g at 10 A, which is more than 2 times powerful than the traditional ones. Hence, it could lighten the half weight of the harvester at the same conditions.

  12. A novel high-density power energy harvesting methodology for transmission line online monitoring devices.

    PubMed

    Liu, Yadong; Xie, Xiaolei; Hu, Yue; Qian, Yong; Sheng, Gehao; Jiang, Xiuchen; Liu, Yilu

    2016-07-01

    This paper presents a novel energy-harvesting model which takes the primary current, secondary turns, dimension, the magnitude of magnetic flux density B, and the core loss resistance into consideration systematically. The relationship among the potential maximum output power, the dimension of energy harvesting coil (EHC), the load type of EHC, and the secondary turns is predicted by theoretical analysis and further verified by experiments. A high power density harvester is also developed and tested. It is shown that the power density of this novel harvester is 0.7 mW/g at 10 A, which is more than 2 times powerful than the traditional ones. Hence, it could lighten the half weight of the harvester at the same conditions. PMID:27475607

  13. Exploring the power of rice (O. sativa x O. rufipogon) chromosome segment substitution line libraries

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Transgressive variation was reported as an increase in grain yield for several rice (Oryza sativa x O. rufipogon) advanced backcross mapping populations. The objective of this study was to develop chromosome segment substitution line (CSSL) libraries to further dissect the reported transgressive var...

  14. Power-Laws and the Use of Pluripotent Stem Cell Lines

    PubMed Central

    Lenz, Michael; Kobold, Sabine; MacArthur, Ben D.; Schuppert, Andreas; Löser, Peter; Müller, Franz-Josef

    2013-01-01

    It is widely accepted that the (now reversed) Bush administration’s decision to restrict federal funding for human embryonic stem cell (hESC) research to a few “eligible” hESC lines is responsible for the sustained preferential use of a small subset of hESC lines (principally the H1 and H9 lines) in basic and preclinical research. Yet, international hESC usage patterns, in both permissive and restrictive political environments, do not correlate with a specific type of stem cell policy. Here we conducted a descriptive analysis of hESC line usage and compared the ability of policy-driven processes and collaborative processes inherent to biomedical research to recapitulate global hESC usage patterns. We find that current global hESC usage can be modelled as a cumulative advantage process, independent of restrictive or permissive policy influence, suggesting a primarily innovation-driven (rather than policy-driven) mechanism underlying human pluripotent stem cell usage in preclinical research. PMID:23300961

  15. Combining Data From Multiple Inbred Line Crosses Improves the Power and Resolution of Quantitative Trait Loci Mapping

    PubMed Central

    Li, Renhua; Lyons, Malcolm A.; Wittenburg, Henning; Paigen, Beverly; Churchill, Gary A.

    2005-01-01

    Rodent inbred line crosses are widely used to map genetic loci associated with complex traits. This approach has proven to be powerful for detecting quantitative trait loci (QTL); however, the resolution of QTL locations, typically ∼20 cM, means that hundreds of genes are implicated as potential candidates. We describe analytical methods based on linear models to combine information available in two or more inbred line crosses. Our strategy is motivated by the hypothesis that common inbred strains of the laboratory mouse are derived from a limited ancestral gene pool and thus QTL detected in multiple crosses are likely to represent shared ancestral polymorphisms. We demonstrate that the combined-cross analysis can improve the power to detect weak QTL, can narrow support intervals for QTL regions, and can be used to separate multiple QTL that colocalize by chance. Moreover, combined-cross analysis can establish the allelic states of a QTL among a set of parental lines, thus providing critical information for narrowing QTL regions by haplotype analysis. PMID:15654110

  16. Finite time-Lyapunov based approach for robust adaptive control of wind-induced oscillations in power transmission lines

    NASA Astrophysics Data System (ADS)

    Ghabraei, Soheil; Moradi, Hamed; Vossoughi, Gholamreza

    2016-06-01

    Large amplitude oscillation of the power transmission lines, which is also known as galloping phenomenon, has hazardous consequences such as short circuiting and failure of transmission line. In this article, to suppress the undesirable vibrations of the transmission lines, first the governing equations of transmission line are derived via mode summation technique. Then, due to the occurrence of large amplitude vibrations, nonlinear quadratic and cubic terms are included in the derived linear equations. To suppress the vibrations, arbitrary number of the piezoelectric actuators is assumed to exert the actuation forces. Afterwards, a Lyapunov based approach is proposed for the robust adaptive suppression of the undesirable vibrations in the finite time. To compensate the supposed parametric uncertainties with unknown bands, proper adaption laws are introduced. To avoid the vibration devastating consequences as quickly as possible, appropriate control laws are designed. The vibration suppression in the finite time with supposed adaption and control laws is mathematically proved via Lyapunov finite time stability theory. Finally, to illustrate and validate the efficiency and robustness of the proposed finite time control scheme, a parametric case study with three piezoelectric actuators is performed. It is observed that the proposed active control strategy is more efficient and robust than the passive control methods.

  17. C IV and He II line emission of Lyman α blobs: powered by shock-heated gas

    NASA Astrophysics Data System (ADS)

    Cabot, Samuel H. C.; Cen, Renyue; Zheng, Zheng

    2016-10-01

    Utilizing ab initio ultrahigh resolution hydrodynamical simulations, we investigate the properties of the interstellar and circumgalactic medium of Lyα blobs (LABs) at z = 3, focusing on three important emission lines: Lyα 1216 Å, He II 1640 Å and C IV 1549 Å. Their relative strengths provide a powerful probe of the thermodynamic properties of the gas when confronted with observations. By adjusting the dust attenuation effect using one parameter and matching the observed size-luminosity relation of LABs using another parameter, we show that our simulations can reproduce the observed C IV/Lyα and He II/Lyα ratios adequately. This analysis provides the first successful physical model to account for simultaneously the LAB luminosity function, luminosity-size relation and the C IV/Lyα and He II/Lyα ratios, with only two parameters. The physical underpinning for this model is that, in addition to the stellar component for the Lyα emission, the Lyα and C IV emission lines due to shock-heated gas are primarily collisional excitation driven and the He II emission line collisional ionization driven. We find that the density, temperature and metallicity of the gas responsible for each emission line is significantly distinct, in a multiphase interstellar and circumgalactic medium that is shock heated primarily by supernovae and secondarily by gravitational accretion of gas.

  18. Adaptive on-line classification for EEG-based brain computer interfaces with AAR parameters and band power estimates.

    PubMed

    Vidaurre, C; Schlögl, A; Cabeza, R; Scherer, R; Pfurtscheller, G

    2005-11-01

    We present the result of on-line feedback Brain Computer Interface experiments using adaptive and non-adaptive feature extraction methods with an on-line adaptive classifier based on Quadratic Discriminant Analysis. Experiments were performed with 12 naïve subjects, feedback was provided from the first moment and no training sessions were needed. Experiments run in three different days with each subject. Six of them received feedback with Adaptive Autoregressive parameters and the rest with logarithmic Band Power estimates. The study was done using single trial analysis of each of the sessions and the value of the Error Rate and the Mutual Information of the classification were used to discuss the results. Finally, it was shown that even subjects starting with a low performance were able to control the system in a few hours: and contrary to previous results no differences between AAR and BP estimates were found.

  19. The Nexawatt: A Strategy for Exawatt Peak Power Lasers Based on NIF and NIF-like Beam Lines

    NASA Astrophysics Data System (ADS)

    Barty, C. P. J.

    2016-05-01

    An exawatt-scale, short-pulse amplification architecture based upon a novel pulse compressor arrangement and amplification of long-duration chirped beam pulses is described. This architecture is capable of extracting the full, stored energy of a NIF or NIF-like beam line and in doing so produce from one beam line a near-diffraction-limited, laser pulse whose peak power would exceed 0.2 EW. The architecture is well suited to either low-f-number focusing or to multi-beam, dipole focusing concepts that in principle enable focused intensities in the range of 1026 W/cm2 or 5 orders of magnitude beyond that possible from present PW systems based on chirped pulse amplification.

  20. Circuit for Communication over DC Power Line Using High Temperature Electronics

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor)

    2014-01-01

    A high temperature communications circuit includes a power conductor for concurrently conducting electrical energy for powering circuit components and transmitting a modulated data signal, and a demodulator for demodulating the data signal and generating a serial bit stream based on the data signal. The demodulator includes an absolute value amplifier for conditionally inverting or conditionally passing a signal applied to the absolute value amplifier. The absolute value amplifier utilizes no diodes to control the conditional inversion or passing of the signal applied to the absolute value amplifier.

  1. Environmental studies for a 1100-kV power line in Oregon. A special report

    SciTech Connect

    Rogers, L.; Hinds, R.

    1983-01-01

    In the first research project to monitor the effects of 1100-kV transmission on a natural ecosystem, researchers at Battelle, Pacific Northwest Laboratories have studied responses of wildlife, native plants, honeybees, and agricultural crops and cattle. No adverse effects were detected on wildlife, crops or cattle. Effects were observed on trees growing within the defined right of way and on honeybee colonies placed beneath the line.

  2. Theory of magnetically insulated electron flows in coaxial pulsed power transmission lines

    NASA Astrophysics Data System (ADS)

    Lawconnell, Robert I.; Neri, Jesse

    1990-03-01

    The Cartesian magnetically insulated transmission line (MITL) theory of Mendel et al. [Appl. Phys. 50, 3830 (1979); Phys. Fluids 26, 3628 (1983)] is extended to cylindrical coordinates. A set of equations that describe arbitrary electron flows in cylindrical coordinates is presented. These equations are used to derive a general theory for laminar magnetically insulated electron flows. The laminar theory allows one to specify the potentials, fields, and densities across a coaxial line undergoing explosive electron emission at the cathode. The theory is different from others available in cylindrical coordinates in that the canonical momentum and total energy for each electron may be nonzero across the electron sheath. A nonzero canonical momentum and total energy for the electrons in the sheath allows the model to produce one-dimensional flows that resemble flows from lines with impedance mismatches and perturbing structures. The laminar theory is used to derive two new self-consistent cylindrical flow solutions: (1) for a constant density profile and (2) for a quadratic density profile of the form ρ=ρc[(r2m-r2)/(r2m-r2c)]. This profile is of interest in that it is similar to profiles observed in a long MITL simulation [Appl. Phys. 50, 4996 (1979)]. The theoretical flows are compared to numerical results obtained with two-dimensional (2-D) electromagnetic particle-in-cell (PIC) codes.

  3. An Ac transposon system based on maize chromosome 4S for isolating long-distance-transposed Ac tags in the maize genome.

    PubMed

    Wang, Fei; Li, Zhaoying; Fan, Jun; Li, Pengfei; Hu, Wei; Wang, Gang; Xu, Zhengkai; Song, Rentao

    2010-12-01

    Transposon tagging is an important tool for gene isolation and functional studies. In maize, several transposon-tagging systems have been developed, mostly using Activator/Dissociation (Ac/Ds) and Mutator systems. Here, we establish another Ac-based transposon system with the donor Ac tightly linked with sugary1 (su1) on maize chromosome 4S. Newly transposed Ac (tr-Acs) were detected based on a negative dosage effect, and long-distance-transposed Ac events were identified and isolated from the donor Ac by a simple backcross scheme. In this study, we identified 208 independent long-distance-transposed Ac lines. Thirty-one flanking sequences of these tr-Acs were isolated and localized in the maize genome. As found in previous studies, the tr-Acs preferentially inserted into genic sequences. The distribution of tr-Acs is not random. In our study, the tr-Acs preferentially transposed into chromosomes 1, 2, 9 and 10. We discuss the preferential distribution of tr-Acs from Ac systems. Our system is complementary to two other Ac-based regional-mutagenesis systems in maize, and the combined use of these systems will achieve an even and high-density distribution of Ac elements throughout the maize genome for functional-genomics studies.

  4. Development of a hardware-based AC microgrid for AC stability assessment

    NASA Astrophysics Data System (ADS)

    Swanson, Robert R.

    As more power electronic-based devices enable the development of high-bandwidth AC microgrids, the topic of microgrid power distribution stability has become of increased interest. Recently, researchers have proposed a relatively straightforward method to assess the stability of AC systems based upon the time-constants of sources, the net bus capacitance, and the rate limits of sources. In this research, a focus has been to develop a hardware test system to evaluate AC system stability. As a first step, a time domain model of a two converter microgrid was established in which a three phase inverter acts as a power source and an active rectifier serves as an adjustable constant power AC load. The constant power load can be utilized to create rapid power flow transients to the generating system. As a second step, the inverter and active rectifier were designed using a Smart Power Module IGBT for switching and an embedded microcontroller as a processor for algorithm implementation. The inverter and active rectifier were designed to operate simultaneously using a synchronization signal to ensure each respective local controller operates in a common reference frame. Finally, the physical system was created and initial testing performed to validate the hardware functionality as a variable amplitude and variable frequency AC system.

  5. Image power for size analysis in in-line Fraunhofer holography.

    PubMed

    Vikram, C S

    1996-07-15

    The role of total power contained within the reconstructed image in size analysis has been described. Using an aperture-limited hologram and a circular-cross-section opaque object as an example, we show that very accurate size analysis is possible by this mode of analysis.

  6. 33 CFR 222.3 - Clearances for power and communication lines over reservoirs.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE ENGINEERING AND DESIGN § 222.3 Clearances for power and... reservoir projects. (b) Applicability. This regulation applies to all field operating agencies having Civil... clearances required over navigable waters are covered by 33 CFR 322.5(i)(2) and are not affected by...

  7. 33 CFR 222.3 - Clearances for power and communication lines over reservoirs.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE ENGINEERING AND DESIGN § 222.3 Clearances for power and... reservoir projects. (b) Applicability. This regulation applies to all field operating agencies having Civil... clearances required over navigable waters are covered by 33 CFR 322.5(i)(2) and are not affected by...

  8. 33 CFR 222.3 - Clearances for power and communication lines over reservoirs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., DEPARTMENT OF THE ARMY, DEPARTMENT OF DEFENSE ENGINEERING AND DESIGN § 222.3 Clearances for power and... reservoir projects. (b) Applicability. This regulation applies to all field operating agencies having Civil... clearances required over navigable waters are covered by 33 CFR 322.5(i)(2) and are not affected by...

  9. Low-power integrated-circuit driver for ferrite-memory word lines

    NASA Technical Reports Server (NTRS)

    Katz, S.

    1970-01-01

    Composite circuit uses both n-p-n bipolar and p-channel MOS transistors /BIMOS/. The BIMOS driver provides 1/ ease of integrated circuit construction, 2/ low standby power consumption, 3/ bidirectional current pulses, and 4/ current-pulse amplitudes and rise times independent of active device parameters.

  10. A method of lines solution of the transient behavior of the helium cooled power leads for the SSC

    SciTech Connect

    Demko, J.A.; Schiesser, W.E.; Carcagno, R.; McAshan, M.

    1995-05-01

    In this study, a detailed numerical thermal mode of a 6.5 kA power lead for the Superconducting Super Collider has been developed, which was adapted from the dynamic model developed by Schiesser. The transient behavior of the power leads was modeled using, a method of lines (MOL) approach. The model was developed to pmvide a tool for analyzing coolant control strategies as well as an understanding of the behavior of the leads under presumed system transients. Results for a current ramp up to 4970 amps are favorably compared with measurements. Also, a loss of cooling situation is predicted to determine the transient temperature distribution under an off-design condition.

  11. Longitudinal variations of very-low-frequency chorus activity in the magnetosphere - Evidence of excitation by electrical power transmission lines

    NASA Technical Reports Server (NTRS)

    Luette, J. P.; Park, C. G.; Helliwell, R. A.

    1977-01-01

    The distribution of VLF chorus in the high-altitude magnetosphere as detected by the Ogo 3 satellite was investigated. Chorus occurrence frequency over 4,668 samples of 5 min of broadband data was computed for Northern Hemisphere bins of 10 deg by 10 deg in dipole invariant latitude and longitude. Peaks in activity were noted over Alaska, the eastern U.S. and Canada, western Europe, and western Siberia, and were shown not to be the result of biased sampling. It is suggested that power line radiation of only about 1 W or less at a given harmonic frequency may be sufficient to stimulate the observed chorus activity and that such power levels can be expected in industrial areas or from large distribution networks. Preliminary results show that chorus starting frequencies are highly correlated with 60 Hz harmonics in the American sector and with 50 Hz harmonics in the European sector.

  12. Non-Federal Participation in AC Intertie : Final Environmental Impact Statement. Volume 1: Environmental Analysis.

    SciTech Connect

    United States. Bonneville Power Administration.

    1994-01-01

    Bonneville Power Administration (BPA) is considering action in two areas: (1) non-Federal access to the AC Intertie, and, (2) BPA Intertie marketing. BPA`s preferred alternative for non-Federal access is the Capacity Ownership alternative combined with the Increased Assured Delivery -- Access for Non-Scheduling Utilities alternative; the preferred alternative for BPA Intertie marketing is the Federal Marketing and Joint Ventures alternative. BPA considered these two areas previously in its Intertie Development and Use EIS of April 1988. The EIS resulted in BPA decisions to participate in the construction of the Third AC Intertie, to allow non-Federal access to BPA`s share of the Pacific Northwest-Pacific Southwest (PNW-PSW) Intertie (AC and DC lines) pursuant to a Long-Term Intertie Access Policy (LTIAP), and to pursue BPA`s export marketing alternative. The decision on allowing direct financial non-Federal participation in the Third AC line was deferred to a later, separate process, examined here. Also, BPA`s export marketing objectives must now be examined in view of changed operations of Columbia River hydro facilities for improved fish survival.

  13. Highly efficient degradation of 4-nitrophenol over the catalyst of Mn2O3/AC by microwave catalytic oxidation degradation method.

    PubMed

    Yin, Cheng; Cai, Jinjun; Gao, Lingfei; Yin, Jingya; Zhou, Jicheng

    2016-03-15

    A new microwave catalytic oxidation process based on two kinds of catalysts, the commercially available activated carbon (AC) and Mn2O3 nanoparticle modified AC (Mn2O3/AC), was reported for the degradation of 4-nitrophenol (4-NP) without adding any oxidant. Effects of microwave power, catalyst dosage, irradiation time, and initial concentration for the degradation efficiency were studied. Results indicated that catalyst of Mn2O3/AC showed much higher catalytic activity than pure AC and Mn2O3 particles. Significantly, 4-NP degradation efficiency reached 99.6%, corresponding to 93.5% TOC removal under optimal conditions with microwave power of 400W, Mn2O3/AC dosage of 2g, reaction time of 5min, and initial concentration of 100mg/L. Hydroxyl radicals (OH) generated during catalytic reaction is the main oxidant, and O2 can not effectively improve removal rate. We proposed the microwave 'photoelectric effect' to interpret the generation of OH in view that microwave irradiation can directly excite the catalyst to produce electron-hole pairs and then transform H2O into OH on the surface of catalyst in solution. The obtained kinetic equation for microwave catalytic oxidation degradation of 4-NP was in line with pseudo-first-order kinetic model, that is, apparent rate constant increased as microwave power density increase.

  14. Highly efficient degradation of 4-nitrophenol over the catalyst of Mn2O3/AC by microwave catalytic oxidation degradation method.

    PubMed

    Yin, Cheng; Cai, Jinjun; Gao, Lingfei; Yin, Jingya; Zhou, Jicheng

    2016-03-15

    A new microwave catalytic oxidation process based on two kinds of catalysts, the commercially available activated carbon (AC) and Mn2O3 nanoparticle modified AC (Mn2O3/AC), was reported for the degradation of 4-nitrophenol (4-NP) without adding any oxidant. Effects of microwave power, catalyst dosage, irradiation time, and initial concentration for the degradation efficiency were studied. Results indicated that catalyst of Mn2O3/AC showed much higher catalytic activity than pure AC and Mn2O3 particles. Significantly, 4-NP degradation efficiency reached 99.6%, corresponding to 93.5% TOC removal under optimal conditions with microwave power of 400W, Mn2O3/AC dosage of 2g, reaction time of 5min, and initial concentration of 100mg/L. Hydroxyl radicals (OH) generated during catalytic reaction is the main oxidant, and O2 can not effectively improve removal rate. We proposed the microwave 'photoelectric effect' to interpret the generation of OH in view that microwave irradiation can directly excite the catalyst to produce electron-hole pairs and then transform H2O into OH on the surface of catalyst in solution. The obtained kinetic equation for microwave catalytic oxidation degradation of 4-NP was in line with pseudo-first-order kinetic model, that is, apparent rate constant increased as microwave power density increase. PMID:26642442

  15. Modelling and optimization of transient processes in line focusing power plants with single-phase heat transfer medium

    NASA Astrophysics Data System (ADS)

    Noureldin, K.; González-Escalada, L. M.; Hirsch, T.; Nouri, B.; Pitz-Paal, R.

    2016-05-01

    A large number of commercial and research line focusing solar power plants are in operation and under development. Such plants include parabolic trough collectors (PTC) or linear Fresnel using thermal oil or molten salt as the heat transfer medium (HTM). However, the continuously varying and dynamic solar condition represent a big challenge for the plant control in order to optimize its power production and to keep the operation safe. A better understanding of the behaviour of such power plants under transient conditions will help reduce defocusing instances, improve field control, and hence, increase the energy yield and confidence in this new technology. Computational methods are very powerful and cost-effective tools to gain such understanding. However, most simulation models described in literature assume equal mass flow distributions among the parallel loops in the field or totally decouple the flow and thermal conditions. In this paper, a new numerical model to simulate a whole solar field with single-phase HTM is described. The proposed model consists of a hydraulic part and a thermal part that are coupled to account for the effect of the thermal condition of the field on the flow distribution among the parallel loops. The model is specifically designed for large line-focusing solar fields offering a high degree of flexibility in terms of layout, condition of the mirrors, and spatially resolved DNI data. Moreover, the model results have been compared to other simulation tools, as well as experimental and plant data, and the results show very good agreement. The model can provide more precise data to the control algorithms to improve the plant control. In addition, short-term and accurate spatially discretized DNI forecasts can be used as input to predict the field behaviour in-advance. In this paper, the hydraulic and thermal parts, as well as the coupling procedure, are described and some validation results and results of simulating an example field are

  16. Relationship Between Selected Strength and Power Assessments to Peak and Average Velocity of the Drive Block in Offensive Line Play.

    PubMed

    Jacobson, Bert H; Conchola, Eric C; Smith, Doug B; Akehi, Kazuma; Glass, Rob G

    2016-08-01

    Jacobson, BH, Conchola, EC, Smith, DB, Akehi, K, and Glass, RG. Relationship between selected strength and power assessments to peak and average velocity of the drive block in offensive line play. J Strength Cond Res 30(8): 2202-2205, 2016-Typical strength training for football includes the squat and power clean (PC) and routinely measured variables include 1 repetition maximum (1RM) squat and 1RM PC along with the vertical jump (VJ) for power. However, little research exists regarding the association between the strength exercises and velocity of an actual on-the-field performance. The purpose of this study was to investigate the relationship of peak velocity (PV) and average velocity (AV) of the offensive line drive block to 1RM squat, 1RM PC, the VJ, body mass (BM), and body composition. One repetition maximum assessments for the squat and PC were recorded along with VJ height, BM, and percent body fat. These data were correlated with PV and AV while performing the drive block. Peal velocity and AV were assessed using a Tendo Power and Speed Analyzer as the linemen fired, from a 3-point stance into a stationary blocking dummy. Pearson product analysis yielded significant (p ≤ 0.05) correlations between PV and AV and the VJ, the squat, and the PC. A significant inverse association was found for both PV and AV and body fat. These data help to confirm that the typical exercises recommended for American football linemen is positively associated with both PV and AV needed for the drive block effectiveness. It is recommended that these exercises remain the focus of a weight room protocol and that ancillary exercises be built around these exercises. Additionally, efforts to reduce body fat are recommended.

  17. Joint terminals and relay optimization for two-way power line information exchange systems with QoS constraints

    NASA Astrophysics Data System (ADS)

    Wu, Xiaolin; Rong, Yue

    2015-12-01

    The quality-of-service (QoS) criteria (measured in terms of the minimum capacity requirement in this paper) are very important to practical indoor power line communication (PLC) applications as they greatly affect the user experience. With a two-way multicarrier relay configuration, in this paper we investigate the joint terminals and relay power optimization for the indoor broadband PLC environment, where the relay node works in the amplify-and-forward (AF) mode. As the QoS-constrained power allocation problem is highly non-convex, the globally optimal solution is computationally intractable to obtain. To overcome this challenge, we propose an alternating optimization (AO) method to decompose this problem into three convex/quasi-convex sub-problems. Simulation results demonstrate the fast convergence of the proposed algorithm under practical PLC channel conditions. Compared with the conventional bidirectional direct transmission (BDT) system, the relay-assisted two-way information exchange (R2WX) scheme can meet the same QoS requirement with less total power consumption.

  18. Observations of power line harmonic radiation by the low-altitude AUREOL 3 satellite

    SciTech Connect

    Parrot, M.

    1994-03-01

    This paper presents observations of very low frequency radiation in the lower part of the ionosphere from a polar orbiting satellite at low latitudes. It was able to record several observation of low frequency radiation which is very close to a harmonic of the 50 Hz line frequency. The frequency is observed to drift in time, from 1 to 8 Hz/sec. They are not sure how to account for this apparent non-linear coupling of these very low frequency waves into the ionosphere.

  19. An efficient switch-mode power supply using an AC-DC interleaved boost converter and a DC-DC full-bridge topology

    NASA Astrophysics Data System (ADS)

    Lessa Tofoli, Fernando; Gallo, Carlos Alberto

    2011-04-01

    This work presents the conception and analysis of a switch-mode power supply with desirable characteristics of high power factor, low harmonic distortion, regulated output voltage, and high efficiency. An interleaved boost converter associated with a nondissipative snubber is used as a preregulator stage. Additionally, a soft switching full-bridge converter is chosen as DC-DC stage. The combination of both topologies results in the proposed switch-mode power supply. Theoretical background on each one of the converters is presented and analytical results are discussed in order to validate the proposal.

  20. Impact of Line Width and Power of Laser on Radio over Fiber System

    NASA Astrophysics Data System (ADS)

    Sharma, Sakshi; Bhatia, Kamaljeet Singh; Kaur, Harsimrat

    2015-03-01

    In order to increase the capacity of the existing optical communication networks advanced modulation schemes are utilized. Keeping this in view, an radio-over-fiber subcarrier multiplexing (SCM) employing ASK modulation technique is proposed. Response of the system is analysed by varying the linewidth and the power of the CW Laser and the optimum value is concluded for the same so as to achieve reliable communication.

  1. The HEMP (high altitude electromagnetic pulse) response of an overhead power distribution line

    SciTech Connect

    Tesche, F.M.; Barnes, P.R.

    1988-01-01

    A study of the HEMP response of a realistic power distribution system was undertaken, and its results are described in this paper. This study involved the following elements: (1) the use of the new HEMP environment, (2) the use of a multiconductor coupling model, and (3) the measurement of the pulse response of an actual distribution transformer to permit the use of this data in the analysis.

  2. Analysis of Iterative Waterfilling Algorithm for Multiuser Power Control in Digital Subscriber Lines

    NASA Astrophysics Data System (ADS)

    Luo, Zhi-Quan; Pang, Jong-Shi

    2006-12-01

    We present an equivalent linear complementarity problem (LCP) formulation of the noncooperative Nash game resulting from the DSL power control problem. Based on this LCP reformulation, we establish the linear convergence of the popular distributed iterative waterfilling algorithm (IWFA) for arbitrary symmetric interference environment and for certain asymmetric channel conditions with any number of users. In the case of symmetric interference crosstalk coefficients, we show that the users of IWFA in fact, unknowingly but willingly, cooperate to minimize a common quadratic cost function whose gradient measures the received signal power from all users. This is surprising since the DSL users in the IWFA have no intention to cooperate as each maximizes its own rate to reach a Nash equilibrium. In the case of asymmetric coefficients, the convergence of the IWFA is due to a contraction property of the iterates. In addition, the LCP reformulation enables us to solve the DSL power control problem under no restrictions on the interference coefficients using existing LCP algorithms, for example, Lemke's method. Indeed, we use the latter method to benchmark the empirical performance of IWFA in the presence of strong crosstalk interference.

  3. Dash line glass- and sapphire-cutting with high power USP laser

    NASA Astrophysics Data System (ADS)

    Mishchik, Konstantin; Chassagne, Bruno; Javaux-Léger, Clémentine; Hönninger, Clemens; Mottay, Eric; Kling, Rainer; Lopez, John

    2016-03-01

    Glass cutting is a subject of high interest for flat panel display and consumer electronics industries. Among laser-based, water jet-based and diamond tool-based existing solutions, ultra-short pulses (USP) appear as a promising technology since this laser technology has the unique capacity to produce highly localized bulk modification owing to non-linear absorption. The cutting using USP lasers could be performed either by full ablation which is slow and generates a lot of dust, by controlled fracture propagation which is slow as well and may lead to path deviation, by stealth dicing which produces rough sidewalls, or by self-breaking induced by in-volume laser irradiation. The laser treatment is often continuous which is not necessary to perform glass cutting and may lead to over-exposure. In this paper we report on single pass glass and sapphire cutting using an USP laser (20W @200kHz or 8W@2MHz) using dash line laser treatment along the cutting trajectory. In-volume energy deposition was done along the glass thickness owing to a Bessel beam. The results will be discussed in terms of sidewall profile and roughness, path deviation, rim sharpness, energy dose and feed rate. Dash line treatment enables to tune the energy deposition and to produce the cutting effect but with a narrower heat affected zone, a better sidewall quality and a more accurate trajectory control of the cutting path.

  4. Chemical abundances in high-redshift galaxies: a powerful new emission line diagnostic

    NASA Astrophysics Data System (ADS)

    Dopita, Michael A.; Kewley, Lisa J.; Sutherland, Ralph S.; Nicholls, David C.

    2016-02-01

    This Letter presents a new, remarkably simple diagnostic specifically designed to derive chemical abundances for high redshift galaxies. It uses only the Hα, [N ii] and [S ii] emission lines, which can usually be observed in a single grating setting, and is almost linear up to an abundance of 12+log (O/H) = 9.05. It can be used over the full abundance range encountered in high redshift galaxies. By its use of emission lines located close together in wavelength, it is also independent of reddening. Our diagnostic depends critically on the calibration of the N/O ratio. However, by using realistic stellar atmospheres combined with the N/O vs. O/H abundance calibration derived locally from stars and H ii regions, and allowing for the fact that high-redshift H ii regions have both high ionisation parameters and high gas pressures, we find that the observations of high-redshift galaxies can be simply explained by the models without having to invoke arbitrary changes in N/O ratio, or the presence of unusual quantities of Wolf-Rayet stars in these galaxies.

  5. Single Phase Passive Rectification Versus Active Rectification Applied to High Power Stirling Engines

    NASA Technical Reports Server (NTRS)

    Santiago, Walter; Birchenough, Arthur G.

    2006-01-01

    Stirling engine converters are being considered as potential candidates for high power energy conversion systems required by future NASA explorations missions. These types of engines typically contain two major moving parts, the displacer and the piston, in which a linear alternator is attached to the piston to produce a single phase sinusoidal waveform at a specific electric frequency. Since all Stirling engines perform at low electrical frequencies (less or equal to 100 Hz), space explorations missions that will employ these engines will be required to use DC power management and distribution (PMAD) system instead of an AC PMAD system to save on space and weight. Therefore, to supply such DC power an AC to DC converter is connected to the Stirling engine. There are two types of AC to DC converters that can be employed, a passive full bridge diode rectifier and an active switching full bridge rectifier. Due to the inherent line inductance of the Stirling Engine-Linear Alternator (SE-LA), their sinusoidal voltage and current will be phase shifted producing a power factor below 1. In order to keep power the factor close to unity, both AC to DC converters topologies will implement power factor correction. This paper discusses these power factor correction methods as well as their impact on overall mass for exploration applications. Simulation results on both AC to DC converters topologies with power factor correction as a function of output power and SE-LA line inductance impedance are presented and compared.

  6. No effects of power line frequency extremely low frequency electromagnetic field exposure on selected neurobehavior tests of workers inspecting transformers and distribution line stations versus controls.

    PubMed

    Li, Li; Xiong, De-fu; Liu, Jia-wen; Li, Zi-xin; Zeng, Guang-cheng; Li, Hua-liang

    2014-03-01

    We aimed to evaluate the interference of 50 Hz extremely low frequency electromagnetic field (ELF-EMF) occupational exposure on the neurobehavior tests of workers performing tour-inspection close to transformers and distribution power lines. Occupational short-term "spot" measurements were carried out. 310 inspection workers and 300 logistics staff were selected as exposure and control. The neurobehavior tests were performed through computer-based neurobehavior evaluation system, including mental arithmetic, curve coincide, simple visual reaction time, visual retention, auditory digit span and pursuit aiming. In 500 kV areas electric field intensity at 71.98% of total measured 590 spots were above 5 kV/m (national occupational standard), while in 220 kV areas electric field intensity at 15.69% of total 701 spots were above 5 kV/m. Magnetic field flux density at all the spots was below 1,000 μT (ICNIRP occupational standard). The neurobehavior score changes showed no statistical significance. Results of neurobehavior tests among different age, seniority groups showed no significant changes. Neurobehavior changes caused by daily repeated ELF-EMF exposure were not observed in the current study. PMID:24379132

  7. Current densities and total contact currents for 110 and 220 kV power line tasks.

    PubMed

    Korpinen, Leena; Kuisti, Harri; Elovaara, Jarmo

    2014-10-01

    The aim of this study was to analyze all values of electric current from measured periods while performing tasks on 110 and 220 kV power lines. Additionally, the objective was to study the average current densities and average total contact currents caused by electric fields in 110 and 220 kV power line tasks. One worker simulated the following tasks: (A) tested insulation voltage at a 110 kV portal tower, (B) checked the wooden towers for rot at a 110 kV portal tower, (C) tested insulation voltage at a 220 kV portal tower, and (D) checked the wooden towers for rot at a 220 kV portal tower. The highest average current density in the neck was 2.0 mA/m(2) (calculated internal electric field was 19.0-38.0 mV/m), and the highest average contact current was 234 µA. All measured values at 110 and 220 kV towers were lower than the basic restrictions (0.1 and 0.8 V/m) of the International Commission on Non-ionizing Radiation Protection.

  8. Chromosome Segment Substitution Lines: A Powerful Tool for the Introgression of Valuable Genes from Oryza Wild Species into Cultivated Rice (O. sativa)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Wild species of rice (genus Oryza) contain many useful genes but a vast majority of these genes remain untapped to date because it is often difficult to transfer these genes into cultivated rice (O. sativa L.). Chromosome segment substitution lines (CSSLs) and backcross inbred lines (BILs) are power...

  9. Microfabricated AC impedance sensor

    DOEpatents

    Krulevitch, Peter; Ackler, Harold D.; Becker, Frederick; Boser, Bernhard E.; Eldredge, Adam B.; Fuller, Christopher K.; Gascoyne, Peter R. C.; Hamilton, Julie K.; Swierkowski, Stefan P.; Wang, Xiao-Bo

    2002-01-01

    A microfabricated instrument for detecting and identifying cells and other particles based on alternating current (AC) impedance measurements. The microfabricated AC impedance sensor includes two critical elements: 1) a microfluidic chip, preferably of glass substrates, having at least one microchannel therein and with electrodes patterned on both substrates, and 2) electrical circuits that connect to the electrodes on the microfluidic chip and detect signals associated with particles traveling down the microchannels. These circuits enable multiple AC impedance measurements of individual particles at high throughput rates with sufficient resolution to identify different particle and cell types as appropriate for environmental detection and clinical diagnostic applications.

  10. VLF Radio Field Strength Measurement of power line carrier system in San Diego, California

    NASA Technical Reports Server (NTRS)

    Mertel, H. K.

    1981-01-01

    The radio frequency interference (RFI) potential was evaluated for a Powerline Carriet (PLC) installed in San Diego which monitors the performance of an electrical power system. The PLC system generated 30 amperes at 5.79 kHz. The RF radiations were measured to be (typically) 120 dBuV/m at the beginning of the 12 kV powerline and 60 dBuV/m at the end of the powerline. The RF fields varied inversely as the distance squared. Measurements were also performed with a 45 kHz PLC system. The RF fields were of similar amplitude.

  11. Transient AC voltage related phenomena for HVDC schemes connected to weak AC systems

    SciTech Connect

    Pilotto, L.A.S.; Szechtman, M. ); Hammad, A.E. )

    1992-07-01

    In this paper a didactic explanation of voltage stability associated phenomena at HVDC terminals is presented. Conditions leading to ac voltage collapse problems are identified. A mechanism that excites control-induced voltage oscillations is shown. The voltage stability factor is used for obtaining the maximum power limits of ac/dc systems operating with different control strategies. Correlation to Pd {times} Id curves is given. Solutions for eliminating the risks of voltage collapse and for avoiding control-induced oscillations are discussed. The results are supported by detailed digital simulations of a weak ac/dc system using EMTP.

  12. Variable transposition of eight maize activator (ac) elements located on the short arm of chromosome 1.

    PubMed

    Sheridan, William F

    2011-09-01

    Eight Activator (Ac) transposable elements mapped to the maize chromosome arm 1S were assessed for Ac transposition rates. For each of the Ac stocks, plants homozygous for the single Ac element and the Ds reporter r1-sc:m3 on chromosome 10 were crossed as females by a homozygous r1-sc:m3 tester color-converted W22 line. The resulting ears produced mostly coarsely spotted kernels and a low frequency of either near-colorless fine-spotted kernels or nonspotted kernels. The relative frequency of these two types of near-colorless kernels differed among the eight Ac stocks. The extent to which increased Ac dosage results in nonspotted kernels may be Ac-specific. Although all of the Ac elements are in near-isogenic inbred W22 lines, they varied to a large extent in their transposition frequency. These differences might possibly result from structural differences among the Ac elements. Because one pair of Ac elements derived from Ac33 on chromosome arm 5S differed about 13-fold in transposition frequency and a second pair of Ac elements derived from Ac12 on chromosome arm 1S differed about 3-fold in transposition frequency, this is not a likely explanation for all eight Ac elements. The data presented here support the notion that the differences in transposition frequency of the eight Ac elements may be a reflection of variability in Ac transcription or accessibility of the transposase to the Ac element, resulting from differences in the chromatin environments wherein the Ac elements are located. This is the first report of variability in transposition rates among different Ac donor lines.

  13. Power lines: Derrida, discursive psychology and the management of accusations of teacher bullying.

    PubMed

    Hepburn, A

    2000-12-01

    This study connects broad issues of classroom control and the disciplining of pupils by teachers with a detailed examination of the way teachers deal with an implied accusation that they have been bullying. The analysis of interviews develops with reference to discursive psychology and Derrida's development of deconstruction. Billig's (1992) insights into ways that participants' accounts can neutralize threats to established social arrangements are employed in relating detailed analytic points to the broader power relations between teacher and pupil. Interviews were conducted with Scottish secondary school teachers, and subjected to close textual analysis. This resulted in the development of three themes: (1) Subjectivity Construction, in which the functional role of the construction of mental entities is examined; (2) Normalizing Techniques, identifying strategies whereby intimidation can be constructed as normal; and (3) Figuration, examining the utility of figurative language--metaphors, maxims, and so on. These themes display the subtlety and complexity of teachers' strategies for distancing themselves from being held accountable for reported intimidation. To conclude, three broader features of the study are discussed: the contribution to discursive psychology that Derrida's deconstructive philosophy can make; the respecification of psychology and subjectivity as participants' resources for action; and the contribution that this type of detailed study can make to issues of power and social critique. PMID:11190687

  14. Power lines: Derrida, discursive psychology and the management of accusations of teacher bullying.

    PubMed

    Hepburn, A

    2000-12-01

    This study connects broad issues of classroom control and the disciplining of pupils by teachers with a detailed examination of the way teachers deal with an implied accusation that they have been bullying. The analysis of interviews develops with reference to discursive psychology and Derrida's development of deconstruction. Billig's (1992) insights into ways that participants' accounts can neutralize threats to established social arrangements are employed in relating detailed analytic points to the broader power relations between teacher and pupil. Interviews were conducted with Scottish secondary school teachers, and subjected to close textual analysis. This resulted in the development of three themes: (1) Subjectivity Construction, in which the functional role of the construction of mental entities is examined; (2) Normalizing Techniques, identifying strategies whereby intimidation can be constructed as normal; and (3) Figuration, examining the utility of figurative language--metaphors, maxims, and so on. These themes display the subtlety and complexity of teachers' strategies for distancing themselves from being held accountable for reported intimidation. To conclude, three broader features of the study are discussed: the contribution to discursive psychology that Derrida's deconstructive philosophy can make; the respecification of psychology and subjectivity as participants' resources for action; and the contribution that this type of detailed study can make to issues of power and social critique.

  15. Line-focus solar central power system, Phase I. Final report, 29 September 1978 to 30 April 1980. Volume II. Text

    SciTech Connect

    Slemmons, A J

    1980-04-01

    The conceptual design, parametric analysis, cost and performance analysis, and a commercial assessment of a 100-MWe high-temperature line-focus central power system are presented. Parametric analyses and conceptual design of the heliostat subsystem, receiver subsystem, heat transport subsystem, energy storage subsystem, electrical power generating subsystem, and master control subsystem are included. A market analysis and development plan are given. (WHK)

  16. AC magnetohydrodynamic microfluidic switch

    SciTech Connect

    Lemoff, A V; Lee, A P

    2000-03-02

    A microfluidic switch has been demonstrated using an AC Magnetohydrodynamic (MHD) pumping mechanism in which the Lorentz force is used to pump an electrolytic solution. By integrating two AC MHD pumps into different arms of a Y-shaped fluidic circuit, flow can be switched between the two arms. This type of switch can be used to produce complex fluidic routing, which may have multiple applications in {micro}TAS.

  17. Protection relay of phase-shifting device with thyristor switch for high voltage power transmission lines

    NASA Astrophysics Data System (ADS)

    Lachugin, V. F.; Panfilov, D. I.; Akhmetov, I. M.; Astashev, M. G.; Shevelev, A. V.

    2014-12-01

    Problems of functioning of differential current protection systems of phase shifting devices (PSD) with mechanically changed coefficient of transformation of shunt transformer are analyzed. Requirements for devices of protection of PSD with thyristor switch are formulated. Based on use of nonlinear models of series-wound and shunt transformers of PSD modes of operation of major protection during PSD, switching to zero load operation and to operation under load and during short circuit operation were studied for testing PSD with failures. Use of the principle of duplicating by devices of differential current protection (with realization of functions of breaking) of failures of separate pares of PSD with thyristor switch was substantiated. To ensure protection sensitivity to the shunt transformer winding short circuit, in particular, to a short circuit that is not implemented in the current differential protection for PSD with mechanical switch, the differential current protection reacting to the amount of primary ampere-turns of high-voltage and low-voltage winding of this transformer was designed. Studies have shown that the use of differential current cutoff instead of overcurrent protection for the shunt transformer wndings allows one to provide the sensitivity during thyristor failure with the formation of a short circuit. The results of simulation mode for the PSD with switch thyristor designed to be installed as switching point of Voskhod-Tatarskaya-Barabinsk 220 kV transmission line point out the efficiency of the developed solutions that ensure reliable functioning of the PSD.

  18. Isolation of sequences flanking Ac insertion sites by Ac casting.

    PubMed

    Wang, Dafang; Peterson, Thomas

    2013-01-01

    Localizing Ac insertions is a fundamental task in studying Ac-induced mutation and chromosomal rearrangements involving Ac elements. Researchers may sometimes be faced with the situation in which the sequence flanking one side of an Ac/Ds element is known, but the other flank is unknown. Or, a researcher may have a small sequence surrounding the Ac/Ds insertion site and needs to obtain additional flanking genomic sequences. One way to rapidly clone unknown Ac/Ds flanking sequences is via a PCR-based method termed Ac casting. This approach utilizes the somatic transposition activity of Ac during plant development, and provides an efficient means for short-range genome walking. Here we describe the principle of Ac casting, and show how it can be applied to isolate Ac macrotransposon insertion sites.

  19. Distance to high-voltage power lines and risk of childhood leukemia--an analysis of confounding by and interaction with other potential risk factors.

    PubMed

    Pedersen, Camilla; Bräuner, Elvira V; Rod, Naja H; Albieri, Vanna; Andersen, Claus E; Ulbak, Kaare; Hertel, Ole; Johansen, Christoffer; Schüz, Joachim; Raaschou-Nielsen, Ole

    2014-01-01

    We investigated whether there is an interaction between distance from residence at birth to nearest power line and domestic radon and traffic-related air pollution, respectively, in relation to childhood leukemia risk. Further, we investigated whether adjusting for potential confounders alters the association between distance to nearest power line and childhood leukemia. We included 1024 cases aged <15, diagnosed with leukemia during 1968-1991, from the Danish Cancer Registry and 2048 controls randomly selected from the Danish childhood population and individually matched by gender and year of birth. We used geographical information systems to determine the distance between residence at birth and the nearest 132-400 kV overhead power line. Concentrations of domestic radon and traffic-related air pollution (NOx at the front door) were estimated using validated models. We found a statistically significant interaction between distance to nearest power line and domestic radon regarding risk of childhood leukemia (p = 0.01) when using the median radon level as cut-off point but not when using the 75th percentile (p = 0.90). We found no evidence of an interaction between distance to nearest power line and traffic-related air pollution (p = 0.73). We found almost no change in the estimated association between distance to power line and risk of childhood leukemia when adjusting for socioeconomic status of the municipality, urbanization, maternal age, birth order, domestic radon and traffic-related air pollution. The statistically significant interaction between distance to nearest power line and domestic radon was based on few exposed cases and controls and sensitive to the choice of exposure categorization and might, therefore, be due to chance. PMID:25259740

  20. Reclamation and revegetation along a 250-mile 500 kV power line corridor

    SciTech Connect

    Griffith, E.F.

    1990-12-31

    Reclamation and revegetation success along the Montana Power Company Colstrip to Deepdale 500 kV powerline was monitored from 1985 through 1989. Followup revegetation was hampered by inadequate road and tower site earth work as a result of premature release of the reclamation bond. Drought conditions in 1985 and 1988 seriously affected revegetation efforts, especially on difficult sites. Weed control improved markedly, and all ROW areas are weed free except those next to infested range and cropland where a major cooperative effort is needed to control weeds. Access roads in previously unroaded areas resulted in changes of access, management practices, and cattle grazing behavior, all of which adversely affected revegetation success. Erosion, exacerbated by undersized culverts, the presence of very erodible soils, the occasional untrained contractor, is now the major ROW maintenance concern. Observation of the revegetation efforts clearly shows the need for adequate and appropriate reclamation by qualified equipment operators up front, and a patient, measured effort of continued revegetation, weed control and erosion control over the long term. The bond period of 5 years may not be long enough to achieve the 90 percent revegetation success required by the permit. Future projects guidelines should consider look to a flexible timeframe and more realistic vegetation requirements to account for the effects of non-construction related impacts.

  1. [Removal Algorithm of Power Line Interference in Electrocardiogram Based on Morphological Component Analysis and Ensemble Empirical Mode Decomposition].

    PubMed

    Zhao, Wei; Xiao, Shixiao; Zhang, Baocan; Huang, Xiaojing; You, Rongyi

    2015-12-01

    Electrocardiogram (ECG) signals are susceptible to be disturbed by 50 Hz power line interference (PLI) in the process of acquisition and conversion. This paper, therefore, proposes a novel PLI removal algorithm based on morphological component analysis (MCA) and ensemble empirical mode decomposition (EEMD). Firstly, according to the morphological differences in ECG waveform characteristics, the noisy ECG signal was decomposed into the mutated component, the smooth component and the residual component by MCA. Secondly, intrinsic mode functions (IMF) of PLI was filtered. The noise suppression rate (NSR) and the signal distortion ratio (SDR) were used to evaluate the effect of de-noising algorithm. Finally, the ECG signals were re-constructed. Based on the experimental comparison, it was concluded that the proposed algorithm had better filtering functions than the improved Levkov algorithm, because it could not only effectively filter the PLI, but also have smaller SDR value. PMID:27079083

  2. Placement of Base Stations in Broadband Power Line Communications Access Networks by Means of Multi-criteria Optimization

    NASA Astrophysics Data System (ADS)

    Haidine, Abdelfatteh; Lehnert, Ralf

    Broadband Power Line Communications (B-PLC) technology is an alternative for broadband access networks, allowing bit rates up to currently 200Mbps. This technique uses the wiring of the low-voltage grid in order to offer to the users the telecommunications services, such as Internet, VoIP, VoD, etc. The B-PLC design process is sub-divided into two parts: the Generalized Base Station Placement (GBSP) problem and the PLC Channel Allocation Problem (P-CAP). This paper focuses on GBSP that is modeled as multi-criteria combinatorial optimization problem. Based on our published mathematical modeling, this paper supplies more numerical experiments for the evaluation of Multi-Objective Evolutionary Algorithms (MOEAs) in solving GBSP. Their performance is compared with the single-objective optimization.

  3. Fetal ECG Extraction from Abdominal Signals: A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics

    PubMed Central

    Ţarălungă, Dragoş-Daniel; Ungureanu, Georgeta-Mihaela; Gussi, Ilinca; Strungaru, Rodica; Wolf, Werner

    2014-01-01

    Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements. Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG). When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the extraction of any useful information regarding the fetal health state. Many signal processing methods for cancelling the PLI from biopotentials are available in the literature. In this review study, six different principles are analyzed and discussed, and their performance is evaluated on simulated data (three different scenarios), based on five quantitative performance indices. PMID:24660020

  4. Light-Weight Sensor Package for Precision 3d Measurement with Micro Uavs E.G. Power-Line Monitoring

    NASA Astrophysics Data System (ADS)

    Kuhnert, K.-D.; Kuhnert, L.

    2013-08-01

    The paper describes a new sensor package for micro or mini UAVs and one application that has been successfully implemented with this sensor package. It is intended for 3D measurement of landscape or large outdoor structures for mapping or monitoring purposes. The package can be composed modularly into several configurations. It may contain a laser-scanner, camera, IMU, GPS and other sensors as required by the application. Also different products of the same sensor type have been integrated. Always it contains its own computing infrastructure and may be used for intelligent navigation, too. It can be operated in cooperation with different drones but also completely independent of the type of drone it is attached to. To show the usability of the system, an application in monitoring high-voltage power lines that has been successfully realised with the package is described in detail.

  5. Extensive Sampling of Forest Carbon using High Density Power Line Lidar

    NASA Astrophysics Data System (ADS)

    Hampton, H. M.; Chen, Q.; Dye, D. G.; Hungate, B. A.

    2013-12-01

    unmanaged areas, using high point density lidar collected over transmission line corridors. The lidar metric of quadratic mean height guided our selection of field plots spanning the full range from low to high levels of aboveground biomass across the study region. Before model selection, we minimized two of the major sources of errors in lidar calibration: variance in tree allometry across landscapes and plot edge effects (spatial mismatch between field measurements and lidar points). We tested an assortment of model selection techniques and goodness of fit measures for deriving forest structural metrics of interest. For example, we obtained an R-squared value for aboveground biomass (Mg/ha) of 0.9 using stepwise regression. The forest metrics obtained are being used in the next stage of the project to parameterize biogeochemical models linking terrestrial carbon pools and atmospheric greenhouse gas exchanges.

  6. Routeing of power lines through least-cost path analysis and multicriteria evaluation to minimise environmental impacts

    SciTech Connect

    Bagli, Stefano; Geneletti, Davide; Orsi, Francesco

    2011-04-15

    Least-cost path analysis (LCPA) allows designers to find the 'cheapest' way to connect two locations within a cost surface, which can be computed by combining multiple criteria, and therefore by accounting for different issues (environmental impact, economic investment, etc.). This procedure can be easily implemented with modern Geographic Information System (GIS) technologies, and consequently it has been widely employed to support planning and design of different types of linear infrastructures, ranging from roads to pipelines. This paper presents an approach based on the integration of multicriteria evaluation (MCE) and LCPA to identify the most suitable route for a 132 kV power line. Criteria such as cost, visibility, population density, and ecosystem naturalness were used for the analysis. Firstly, spatial MCE and LCPA were combined to generate cost surfaces, and to identify alternative paths. Subsequently, MCE was used to compare the alternatives, and rank them according to their overall suitability. Finally, a sensitivity analysis allowed the stability of the results to be tested and the most critical factors of the evaluation to be detected. The study found that small changes in the location of the power line start and end points can result in significantly different paths, and consequently impact levels. This suggested that planners should always consider alternative potential locations of terminals in order to identify the best path. Furthermore, it was shown that the use of different weight scenarios may help making the model adaptable to varying environmental and social contexts. The approach was tested on a real-world case study in north-eastern Italy.

  7. Childhood brain tumor occurrence in relation to external power lines and other sources of residential magnetic fields. Final report

    SciTech Connect

    Gurney, J.G.; Mueller, B.A.; Davis, S.

    1995-10-01

    A population-based case-control study of incident brain tumors was conducted in the Seattle area among children younger than 20 years, diagnosed from 1984-1990; mothers of 133 cases and 270 controls participated. The relation between childhood brain tumor occurrence and exposure to potential sources of residential magnetic fields was assessed, focusing on whether proximity to high-current residential power lines or use of electric appliances or electric heating sources by the mother while pregnant or by the child before diagnosis, were associated with increased risks of brain tumor occurrence. For the 120 cases and 240 controls, risk of brain tumor occurrence did not increase with increasing magnetic field exposure as indicated by the 5-level Wertheimer-Leeper (W-L) code. Relative to those with underground wiring, the odds ratios for increasing exposure levels were: very low current configuration, 1.3; ordinary low current configuration, 0.7; ordinary high-current configuration, 1.1; and very high current configuration, 0.5. When exposure was dichotomized as high versus low, the odds ratio was 0.9 (95% CI 0.5-1.5) and did not vary significantly. When the analysis was restricted to the 96 subjects known to live in only one home, the odds ratio was 1.1. The distributions of the 5-level W-L code were similar between study participants and non-respondents, and odds ratios were not appreciably changed when non-respondents were included in the analysis. No elevations in risk were found for ever-versus-never use of electric blankets, water beds, or electric heating sources. Odds ratios were slightly elevated for nine appliances and were at or below 1.0 for eight others. These data do not support the hypothesis that exposure to magnetic fields from high-current power lines, electric heating sources, or electric appliances, is associated with the subsequent occurrence of brain tumors in children.

  8. Wideband and high-power light sources for in-line interferometric diagnostics of laser structuring systems

    NASA Astrophysics Data System (ADS)

    Peterka, Pavel; Todorov, Filip; KašÎ¯k, Ivan; Matějec, Vlastimil; Podrazký, Ondřej; Šašek, Ladislav; Mallmann, Guilherme; Schmitt, Robert

    2012-01-01

    Laser structuring is rapidly developing manufacturing technique for broad spectrum of industrial branches, e.g. aerospace, power engineering, tool- and mould making, and automotive. It enables to prepare work pieces and products with very fine micro structures achieving a far better degree of details than conventional structuring techniques like etching or eroding. However, the state of art in laser structuring shows a crucial deficit. Used systems contain no metrology setup to detect the shape geometry (depth and length) and contour accuracy during the process. Therefore, an innovative in-line metrology technique based on low coherence interferometry for laser structuring systems has been investigated and described in the paper. In this contribution we present our results in the research of wideband and highpower light sources for the proposed low-coherence interferometric measurement system. The system can be incorporated into a structuring workplace equipped with a Q-switched ytterbium-doped fiber laser at 1064 nm for material processing. In the paper we focus on two wideband sources for such a measurement system. The first source is based on a superluminescent diode and the second one is based on an amplified spontaneous emission in a double-clad ytterbium-doped fiber. An example of results measured with the proposed in-line metrology system is presented.

  9. Fabrication of alumina films with laminated structures by ac anodization

    NASA Astrophysics Data System (ADS)

    Segawa, Hiroyo; Okano, Hironaga; Wada, Kenji; Inoue, Satoru

    2014-02-01

    Anodization techniques by alternating current (ac) are introduced in this review. By using ac anodization, laminated alumina films are fabricated. Different types of alumina films consisting of 50-200 nm layers were obtained by varying both the ac power supply and the electrolyte. The total film thickness increased with an increase in the total charge transferred. The thickness of the individual layers increased with the ac voltage; however, the anodization time had little effect on the film thickness. The laminated alumina films resembled the nacre structure of shells, and the different morphologies exhibited by bivalves and spiral shells could be replicated by controlling the rate of increase of the applied potentials.

  10. Scalable Heuristics for Planning, Placement and Sizing of Flexible AC Transmission System Devices

    SciTech Connect

    Frolov, Vladmir; Backhaus, Scott N.; Chertkov, Michael

    2015-07-02

    Aiming to relieve transmission grid congestion and improve or extend feasibility domain of the operations, we build optimization heuristics, generalizing standard AC Optimal Power Flow (OPF), for placement and sizing of Flexible Alternating Current Transmission System (FACTS) devices of the Series Compensation (SC) and Static VAR Compensation (SVC) type. One use of these devices is in resolving the case when the AC OPF solution does not exist because of congestion. Another application is developing a long-term investment strategy for placement and sizing of the SC and SVC devices to reduce operational cost and improve power system operation. SC and SVC devices are represented by modification of the transmission line inductances and reactive power nodal corrections respectively. We find one placement and sizing of FACTs devices for multiple scenarios and optimal settings for each scenario simultaneously. Our solution of the nonlinear and nonconvex generalized AC-OPF consists of building a convergent sequence of convex optimizations containing only linear constraints and shows good computational scaling to larger systems. The approach is illustrated on single- and multi-scenario examples of the Matpower case-30 model.

  11. Wavelength stabilized ns-MOPA diode laser system with 16 W peak power and a spectral line width below 10 pm

    NASA Astrophysics Data System (ADS)

    Nghiem Vu, Thi; Klehr, Andreas; Sumpf, Bernd; Wenzel, Hans; Erbert, Götz; Tränkle, Günther

    2014-03-01

    A master oscillator power amplifier system for the generation of ns-pulses with high peak power, stabilized wavelength and narrow spectral line width will be presented. The master oscillator is a distributed feedback (DFB) ridge waveguide (RW) laser. The tapered amplifier consists of three RW sections and one flared gain-guided section. The DFB laser is operated in continuous wave mode and emits at 1064 nm with a spectral line width below 10 pm. One RW section of the amplifier acts as an optical gate for pulse selection. The tapered section amplifies the generated optical pulse. By adjusting the delay time between the current pulses injected into the picker and into the tapered section, respectively, the power of the amplified spontaneous emission was reduced below 1% of the average laser power. For an optical pulse length of 2 ns, a peak power of 16 W was obtained. A side mode suppression ratio better than 46 dB was observed.

  12. HTS DC Transmission Line for Megalopolis Grid Development

    NASA Astrophysics Data System (ADS)

    Kopylov, S.; Sytnikov, V.; Bemert, S.; Ivanov, Yu; Krivetskiy, I.; Romashov, M.; Shakaryan, Yu; Keilin, V.; Shikov, A.; Patrikeev, V.; Lobyntsev, V.; Shcherbakov, V.

    2014-05-01

    Using of HTS AC and DC cables in electric power grids allows increasing of the transferred power, losses diminishing, decreasing of exclusion zone areas, the enhancement of the environmental conditions and fire/explosion safety of electric power systems. However, the use of DC superconducting cable lines together with converters brings additional advantages as reduction of losses in cables and suitable lowering of refrigerating plant capacity, as well as the realization of the function of short-circuit currents limitation by means of the appropriate setting of converter equipment. Russian Federal Grid Company and its R&D Center started the construction of the DC HTS power transmission line which includes the cable itself, cryogenic equipment, AC/DC converters, terminals and cable coupling boxes. This line will connect two substations in Saint-Petersburg - 330 kV "Centralnaya" and 220 kV "RP-9". The length of this HTS transmission line will be about 2500 meters. Nowadays are developed all the elements of the line and technologies of the cable manufacturing. Two HTS cable samples, each 30 m length, have been made. This paper describes the results of cables tests.

  13. Electrical and mechanical design criteria for EHV and UHV: overhead transmission lines

    SciTech Connect

    Not Available

    1980-06-01

    The results are presented of a program devoted to the selection of electrical and mechanical design criteria and parameters for overhead power transmission lines for ac systems rated at from 345 to 1100 kV and for dc systems rated at from 600 to 1200 kV. Information is included on the environmental effects, i.e., audible noise and electric fields, of the lines, mechanical and economic requirements, safety, failures, grounding, and lightning protection. (LCL)

  14. AC-3 audio coder

    NASA Astrophysics Data System (ADS)

    Todd, Craig

    1995-12-01

    AC-3 is a system for coding up to 5.1 channels of audio into a low bit-rate data stream. High quality may be obtained with compression ratios approaching 12-1 for multichannel audio programs. The high compression ratio is achieved by methods which do not increase decoder memory, and thus cost. The methods employed include: the transmission of a high frequency resolution spectral envelope; and a novel forward/backward adaptive bit allocation algorithm. In order to satisfy practical requirements of an emissions coder, the AC-3 syntax includes a number of features useful to broadcasters and consumers. These features include: loudness uniformity between programs; dynamic range control; and broadcaster control of downmix coefficients. The AC-3 coder has been formally selected for inclusion of the U.S. HDTV broadcast standard, and has been informally selected for several additional applications.

  15. Diagnostics of AC excited Atmospheric Pressure Plasma Jet with He for Biomedical Applications

    NASA Astrophysics Data System (ADS)

    Hori, Masaru; Takeda, Keigo; Kumakura, Takumi; Ishikawa, Kenji; Tanaka, Hiromasa; Kondo, Hiroki; Sekine, Makoto; Nakai, Yoshihiro

    2014-10-01

    Atmospheric pressure plasma jets (APPJ) are frequently used for biomedical applications. Reactive species generated by the APPJ play important roles for treatments of biomedical samples. Therefore, high density APPJ sources are required to realize the high performance. Our group has developed AC excited Ar APPJ with electron density as high as 1015 cm-3, and realized the selective killing of cancer cells and the inactivate spores of Penicillium digitatum. Recently, a new spot-size AC excited APPJ with He gas have been developed. In this study, the He APPJ was characterized by using spectroscopy. The plasma was discharged at a He flow rate of 5 slm and a discharge voltage of AC 9 kV. Gas temperature and electron density of the APPJ were measured by optical emission spectroscopy. From theoretical fitting of 2nd positive system of N2 emission (380.4 nm) and Stark broadening of Balmer β line of H atom (486.1 nm), the gas temperature and the electron density was estimated to be 299 K and 3.4. × 1015 cm-3. The AC excited He APPJ has a potential to realize high density with room temperature and become a very powerful tool for biomedical applications.

  16. ac propulsion system for an electric vehicle

    NASA Technical Reports Server (NTRS)

    Geppert, S.

    1980-01-01

    It is pointed out that dc drives will be the logical choice for current production electric vehicles (EV). However, by the mid-80's, there is a good chance that the price and reliability of suitable high-power semiconductors will allow for a competitive ac system. The driving force behind the ac approach is the induction motor, which has specific advantages relative to a dc shunt or series traction motor. These advantages would be an important factor in the case of a vehicle for which low maintenance characteristics are of primary importance. A description of an EV ac propulsion system is provided, taking into account the logic controller, the inverter, the motor, and a two-speed transmission-differential-axle assembly. The main barrier to the employment of the considered propulsion system in EV is not any technical problem, but inverter transistor cost.

  17. AC/RF Superconductivity

    SciTech Connect

    Ciovati, Gianluigi

    2015-02-01

    This contribution provides a brief introduction to AC/RF superconductivity, with an emphasis on application to accelerators. The topics covered include the surface impedance of normal conductors and superconductors, the residual resistance, the field dependence of the surface resistance, and the superheating field.

  18. Three phase AC motor controller

    DOEpatents

    Vuckovich, Michael; Wright, Maynard K.; Burkett, John P.

    1984-03-20

    A motor controller for a three phase AC motor (10) which is adapted to operate bidirectionally from signals received either from a computer (30) or a manual control (32). The controller is comprised of digital logic circuit means which implement a forward and reverse command signal channel (27, 29) for the application of power through the forward and reverse power switching relays (16, 18, 20, 22). The digital logic elements are cross coupled to prevent activation of both channels simultaneously and each includes a plugging circuit (65, 67) for stopping the motor upon the removal of control signal applied to one of the two channels (27, 29) for a direction of rotation desired. Each plugging circuit (65, 67) includes a one-shot pulse signal generator (88, 102) which outputs a single pulse signal of predetermined pulsewidth which is adapted to inhibit further operation of the application of power in the channel which is being activated and to apply a reversal command signal to the other channel which provides a reversed phase application of power to the motor for a period defined by the pulse-width output of the one-shot signal generator to plug the motor (10) which will then be inoperative until another rotational command signal is applied to either of the two channels.

  19. HVDC power transmission technology assessment

    SciTech Connect

    Hauth, R.L.; Tatro, P.J.; Railing, B.D.; Johnson, B.K.; Stewart, J.R.; Fink, J.L.

    1997-04-01

    The purpose of this study was to develop an assessment of the national utility system`s needs for electric transmission during the period 1995-2020 that could be met by future reduced-cost HVDC systems. The assessment was to include an economic evaluation of HVDC as a means for meeting those needs as well as a comparison with competing technologies such as ac transmission with and without Flexible AC Transmission System (FACTS) controllers. The role of force commutated dc converters was to be assumed where appropriate. The assessment begins by identifying the general needs for transmission in the U.S. in the context of a future deregulated power industry. The possible roles for direct current transmission are then postulated in terms of representative scenarios. A few of the scenarios are illustrated with the help of actual U.S. system examples. non-traditional applications as well as traditional applications such as long lines and asynchronous interconnections are discussed. The classical ``break-even distance`` concept for comparing HVDC and ac lines is used to assess the selected scenarios. The impact of reduced-cost converters is reflected in terms of the break-even distance. This report presents a comprehensive review of the functional benefits of HVDC transmission and updated cost data for both ac and dc system components. It also provides some provocative thoughts on how direct current transmission might be applied to better utilize and expand our nation`s increasingly stressed transmission assets.

  20. Calculation of the ac to dc resistance ratio of conductive nonmagnetic straight conductors by applying FEM simulations

    NASA Astrophysics Data System (ADS)

    Riba, Jordi-Roger

    2015-09-01

    This paper analyzes the skin and proximity effects in different conductive nonmagnetic straight conductor configurations subjected to applied alternating currents and voltages. These effects have important consequences, including a rise of the ac resistance, which in turn increases power loss, thus limiting the rating for the conductor. Alternating current (ac) resistance is important in power conductors and bus bars for line frequency applications, as well as in smaller conductors for high frequency applications. Despite the importance of this topic, it is not usually analyzed in detail in undergraduate and even in graduate studies. To address this, this paper compares the results provided by available exact formulas for simple geometries with those obtained by means of two-dimensional finite element method (FEM) simulations and experimental results. The paper also shows that FEM results are very accurate and more general than those provided by the formulas, since FEM models can be applied in a wide range of electrical frequencies and configurations.