Science.gov

Sample records for ac supply line

  1. Coupling an induction motor type generator to ac power lines. [making windmill generators compatible with public power lines

    NASA Technical Reports Server (NTRS)

    Nola, F. J. (Inventor)

    1984-01-01

    A system for coupling an induction motor type generator to an A.C. power line includes an electronic switch means that is controlled by a control system and is regulated to turn on at a relatively late point in each half cycle of its operation. The energizing power supplied by the line to the induction motor type generator is decreased and the net power delivered to the line is increased.

  2. Wind-powered asynchronous AC/DC/AC converter system. [for electric power supply regulation

    NASA Technical Reports Server (NTRS)

    Reitan, D. K.

    1973-01-01

    Two asynchronous ac/dc/ac systems are modelled that utilize wind power to drive a variable or constant hertz alternator. The first system employs a high power 60-hertz inverter tie to the large backup supply of the power company to either supplement them from wind energy, storage, or from a combination of both at a preset desired current; rectifier and inverter are identical and operate in either mode depending on the silicon control rectifier firing angle. The second system employs the same rectification but from a 60-hertz alternator arrangement; it provides mainly dc output, some sinusoidal 60-hertz from the wind bus and some high harmonic content 60-hertz from an 800-watt inverter.

  3. Plasma characteristics of argon glow discharge produced by AC power supply operating at low frequencies

    SciTech Connect

    Kongpiboolkid, Watcharapon; Mongkolnavin, Rattachat

    2015-04-24

    Non-thermal properties of Argon glow discharge operating with various operating pressures were measured and presented in this work. The Argon plasma is produced by a parallel conducting electrodes coupling with a high voltage AC power supply. The power supply can generate high AC voltage at various frequencies. The frequencies for the operation are in the range of a few kHz. The system is capable of generating electric field between the two metal electrodes discharge system. The characteristics of plasma produced were measured by optical emission spectroscopy (OES) technique where electron temperature (T{sub e}) and electron number density (n{sub e}) can be determined by line intensity ratio method. The value of electron number density was then determined from the Saha-Eggert equation. Our results show that the electron number density of the discharge obtained is of the order of 10{sup −17} − 10{sup −18} m{sup −3} where the electron temperature is between 1.00−2.00 eV for various operating frequencies used which are in good agreement with similar results published earlier.

  4. Very low noise AC/DC power supply systems for large detector arrays

    NASA Astrophysics Data System (ADS)

    Arnaboldi, C.; Baù, A.; Carniti, P.; Cassina, L.; Giachero, A.; Gotti, C.; Maino, M.; Passerini, A.; Pessina, G.

    2015-12-01

    In this work, we present the first part of the power supply system for the CUORE and LUCIFER arrays of bolometric detectors. For CUORE, it consists of AC/DC commercial power supplies (0-60 V output) followed by custom DC/DC modules (48 V input, ±5 V to ±13.5 V outputs). Each module has 3 floating and independently configurable output voltages. In LUCIFER, the AC/DC + DC/DC stages are combined into a commercial medium-power AC/DC source. At the outputs of both setups, we introduced filters with the aim of lowering the noise and to protect the following stages from high voltage spikes that can be generated by the energy stored in the cables after the release of accidental short circuits. Output noise is very low, as required: in the 100 MHz bandwidth the RMS level is about 37 μVRMS (CUORE setup) and 90 μVRMS (LUCIFER setup) at a load of 7 A, with a negligible dependence on the load current. Even more importantly, high frequency switching disturbances are almost completely suppressed. The efficiency of both systems is above 85%. Both systems are completely programmable and monitored via CAN bus (optically coupled).

  5. Very low noise AC/DC power supply systems for large detector arrays.

    PubMed

    Arnaboldi, C; Baù, A; Carniti, P; Cassina, L; Giachero, A; Gotti, C; Maino, M; Passerini, A; Pessina, G

    2015-12-01

    In this work, we present the first part of the power supply system for the CUORE and LUCIFER arrays of bolometric detectors. For CUORE, it consists of AC/DC commercial power supplies (0-60 V output) followed by custom DC/DC modules (48 V input, ±5 V to ±13.5 V outputs). Each module has 3 floating and independently configurable output voltages. In LUCIFER, the AC/DC + DC/DC stages are combined into a commercial medium-power AC/DC source. At the outputs of both setups, we introduced filters with the aim of lowering the noise and to protect the following stages from high voltage spikes that can be generated by the energy stored in the cables after the release of accidental short circuits. Output noise is very low, as required: in the 100 MHz bandwidth the RMS level is about 37 μV(RMS) (CUORE setup) and 90 μV(RMS) (LUCIFER setup) at a load of 7 A, with a negligible dependence on the load current. Even more importantly, high frequency switching disturbances are almost completely suppressed. The efficiency of both systems is above 85%. Both systems are completely programmable and monitored via CAN bus (optically coupled). PMID:26724052

  6. Signal pulses superimposed on power supply lines improve electrical control

    SciTech Connect

    1996-06-01

    To manipulate or monitor the operation of cranes and hoists, control engineers typically create control schemes that add numerous conductors, festoon systems, bulky dedicated conductor rails, radio and infrared controls. With modern power line communication equipment, power and intelligence can be combined to: add an unlimited number of control circuits without adding a single wire; have data communication without special cables; and eliminate bulky festoon systems and heavy cable track. Available from US Safety Trolley Corp., a SmartRail system superimposes data and control information on the power line to create a fully functional Local Area Network (LAN). The system network is based on the CEBus protocol EIA/IS-60 and uses a spread spectrum power line carrier technology. The heart of this system is the controller which manages all communication and control tasks. A power line coupling circuit couples the data signal from the controller to the a-c power conductors. These power conductors are often TRI-BAR/FOUR-BAR continuous conductor bar systems or existing conductor bar systems. The combination results in a secure data communications and control system for moving equipment.

  7. New 48-inch line gives Wales more gas supplies

    SciTech Connect

    Not Available

    1982-11-01

    A new 11-mile, 48-in pipeline will not only supply an even flow of gas from the British Gas national grid to towns in the Wales Gas district but also serve as a daily storage facility by means of nightime linepacking at 700 psi. The largest diameter gas line to be constructed in the UK, the pipeline is confined to a 165-ft wide corridor leading through wet and dry moorland, farms, reclaimed colliery tips, and bogs. Construction engineers took care to protect archeological features along the route and to restore the land to its original condition.

  8. Plasma antennas driven by 5–20 kHz AC power supply

    SciTech Connect

    Zhao, Jiansen Chen, Yuli; Sun, Yang; Wu, Huafeng; Liu, Yue; Yuan, Qiumeng

    2015-12-15

    The experiments described in this work were performed with the aim of introducing a new plasma antenna that was excited by a 5–20 kHz alternating current (AC) power supply, where the antenna was transformed into a U-shape. The results show that the impedance, voltage standing-wave ratio (VSWR), radiation pattern and gain characteristics of the antenna can be controlled rapidly by varying not only the discharge power, but also by varying the discharge frequency in the range from 5 to 20 kHz. When the discharge frequency is adjusted from 10 to 12 kHz, the gain is higher within a relatively broad frequency band and the switch-on time is less than 1 ms when the discharge power is less than 5 W, meaning that the plasma antenna can be turned on and off rapidly.

  9. WATER QUALITY AND TREATMENT CONSIDERATIONS FOR CEMENT-LINED AND A-C PIPE

    EPA Science Inventory

    Both cement mortar lined (CML) and asbestos-cement pipes (A-C) are widely used in many water systems. Cement linings are also commonly applied in-situ after pipe cleaning, usually to prevent the recurrence of red water or tuberculation problems. Unfortunately, little consideratio...

  10. Depinning of flux lines and AC losses in magnet-superconductor levitation system

    SciTech Connect

    Terentiev, A. N.; Hull, J. R.; De Long, L. E.

    1999-11-29

    The AC loss characteristics of a magnet-superconductor system were studied with the magnet fixed to the free end of an oscillating cantilever located near a stationary melt-textured YBCO pellet. Below a threshold AC field amplitude {approx}2Oe, the dissipation of the oscillator is amplitude-independent, characteristic of a linear, non-hysteretic regime. Above threshold,dissipation increases with amplitude, reflecting the depinning and hysteretic motion of flux lines. The threshold AC field is an order of magnitude higher than that measured for the same YBCO material via AC susceptometry in a uniform DC magnetic field, A partial lock-in of flux lines between YBCO ab planes is proposed as the mechanism for the substantial increase of the depinning threshold.

  11. System for transmitting low frequency analog signals over AC power lines

    DOEpatents

    Baker, Steven P.; Durall, Robert L.; Haynes, Howard D.

    1989-09-05

    A system for transmitting low frequency analog signals over AC power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an AC power line. The modulation signal frequency range in selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the AC power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal.

  12. A system for tranmitting low frequency analog signals over ac power lines

    DOEpatents

    Baker, S.P.; Durall, R.L.; Haynes, H.D.

    1987-07-30

    A system for transmitting low frequency analog signals over ac power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an ac power line. The modulation signal frequency range is selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the ac power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal. 4 figs.

  13. System for transmitting low frequency analog signals over AC power lines

    DOEpatents

    Baker, Steven P.; Durall, Robert L.; Haynes, Howard D.

    1989-01-01

    A system for transmitting low frequency analog signals over AC power lines using FM modulation. A low frequency analog signal to be transmitted is first applied to a voltage-to-frequency converter where it is converted to a signal whose frequency varies in proportion to the analog signal amplitude. This signal is then used to modulate the carrier frequency of an FM transmitter coupled to an AC power line. The modulation signal frequency range in selected to be within the response band of the FM transmitter. The FM modulated carrier signal is received by an FM receiver coupled to the AC power line, demodulated and the demodulated signal frequency is converted by a frequency-to-voltage converter back to the form of the original low frequency analog input signal.

  14. Controller for controlling operation of at least one electrical load operating on an AC supply, and a method thereof

    DOEpatents

    Cantin, Luc; Deschenes, Mario; D'Amours, Mario

    1995-08-15

    A controller is provided for controlling operation of at least one electrical load operating on an AC supply having a typical frequency, the AC supply being provided via power transformers by an electrical power distribution grid. The controller is associated with the load and comprises an input interface for coupling the controller to the grid, a frequency detector for detecting the frequency of the AC supply and producing a signal indicative of the frequency, memory modules for storing preprogrammed commands, a frequency monitor for reading the signal indicative of the frequency and producing frequency data derived thereof, a selector for selecting at least one of the preprogrammed commands with respect to the frequency data, a control unit for producing at least one command signal representative of the selected preprogrammed commands, and an output interface including a device responsive to the command signal for controlling the load. Therefore, the load can be controlled by means of the controller depending on the frequency of the AC supply.

  15. Non-Antithrombotic Medical Options in ACS: Old Agents and New Lines on the Horizon

    PubMed Central

    Soukoulis, Victor; Boden, William E.; Smith, Sidney C.; O'Gara, Patrick T.

    2014-01-01

    Acute coronary syndromes (ACS) constitute a spectrum of clinical presentations ranging from unstable angina and non-ST-segment elevation myocardial infarction to ST-segment myocardial infarction. Myocardial ischemia in this context occurs as a result of an abrupt decrease in coronary blood flow and resultant imbalance in the myocardial oxygen supply-demand relationship. Coronary blood flow is further compromised by other mechanisms that increase coronary vascular resistance or reduce coronary driving pressure. The goals of treatment are to decrease myocardial oxygen demand, increase coronary blood flow and oxygen supply, and limit myocardial injury. Treatments are generally divided into “disease-modifying” agents or interventions that improve hard clinical outcomes and other strategies that can reduce ischemia. In addition to traditional drugs such as beta-blockers and inhibitors of the reninangiotensin-aldosterone system, newer agents have expanded the number of molecular pathways targeted for treatment of ACS. Ranolazine, trimetazidine, nicorandil, and ivabradine are medications that have been shown to reduce myocardial ischemia through diverse mechanisms and have been tested in limited fashion in patients with ACS. Attenuating the no-reflow phenomenon and reducing the injury compounded by acute reperfusion after a period of coronary occlusion are active areas of research. Additionally, interventions aimed at ischemic pre- and post-conditioning may be useful means by which to limit myocardial infarct size. Trials are also underway to examine altered metabolic and oxygen-related pathways in ACS. This review will discuss traditional and newer anti-ischemic therapies for patients with ACS, exclusive of revascularization, anti-thrombotic agents, and the use of high-intensity statins. PMID:24902977

  16. Programmable AC power supply for simulating power transient expected in fusion reactor

    SciTech Connect

    Halimi, B.; Suh, K. Y.

    2012-07-01

    This paper focus on control engineering of the programmable AC power source which has capability to simulate power transient expected in fusion reactor. To generate the programmable power source, AC-AC power electronics converter is adopted to control the power of a set of heaters to represent the transient phenomena of heat exchangers or heat sources of a fusion reactor. The International Thermonuclear Experimental Reactor (ITER) plasma operation scenario is used as the basic reference for producing this transient power source. (authors)

  17. ac Stark shifts for cesium and their effect on ionization line shapes

    SciTech Connect

    Pindzola, M.S.; Glasser, A.H.; Payne, M.G.

    1984-10-01

    The influence of ac Stark shifts on the three-photon ionization of cesium in a moderate-intensity laser beam is investigated. The ionization process involves a two-photon resonance with the 8d fine-structure levels. The work consists of two related parts. In the first part, atomic parameters, such as the two-photon Rabi rate and the ac Stark shift, are calculated in the nonrelativistic Hartree-Fock approximation. In the second part, the atomic parameters thus obtained are used as coefficients in a system of coupled differential equations representing the time evolution of the density matrix. Ionization line shapes are generated for a transform-limited pulsed laser of moderate intensity with a single-mode transverse structure. As the time history of the intensity profile is varied from square to smooth, the ionization line shape becomes asymmetric due to the time dependence of the ac Stark shift. The effects of varying the spatial intensity distribution of the laser light to

  18. Stick-Slip to Sliding Transition of Dynamic Contact Lines under AC Electrowetting.

    PubMed

    't Mannetje, D J C M; Mugele, F; van den Ende, D

    2013-12-01

    We show that at low velocities the dynamics of a contact line of a water drop moving over a Teflon-like surface under ac electrowetting must be described as stick-slip motion, rather than one continuous movement. At high velocities we observe a transition to a slipping regime. In the slipping regime the observed dependence of the contact angle is well described by a linearization of both the hydrodynamic and the molecular-kinetic model for the dynamic contact line behavior. The overall geometry of the drop also has a strong influence on the contact angle: if the drop is confined to a disk-like shape with radius R, much larger than the capillary length, and height h, smaller than the capillary length, the advancing angle increases steeper with velocity as the aspect ratio h/R is smaller. Although influence of the flow field near a contact line on the contact angle behavior has also been observed in other experiments, these observations do not fit either model. Finally, in our ac experiments no sudden increase of the hysteresis beyond a certain voltage and velocity was observed, as reported by other authors for a dc voltage, but instead we find with increasing voltage a steady decrease of the hysteresis. PMID:24219094

  19. Power Quality Improvement in Bridgeless Ac-Dc Converter Based Multi-output Switched Mode Power Supply

    NASA Astrophysics Data System (ADS)

    Singh, Shihka; Singh, Bhim; Bhuvaneswari, G.; Bist, Vashist

    2014-12-01

    Computer power supplies are required to have multiple isolated regulated dc voltages with low ripple content and high input power factor at the utility interface. A dc-dc converter is used for obtaining these isolated multi-output dc voltages with excellent regulation. In this paper, a non-isolated ac-dc converter is proposed as the first stage converter to obtain a regulated dc output rather than using a simple uncontrolled diode bridge rectifier at the front end. A dc-dc converter is used at the second stage that has a high frequency transformer with multiple secondary windings to obtain different dc voltage levels at the output. The proposed bridgeless converter based power supply is designed using fundamental design equations, and different component values are calculated. Extensive simulations are carried out to demonstrate the improved performance of the proposed bridgeless converter based multi-output computer power supply at varying source voltages and load conditions. Experimental validation of the power supply is carried on a developed hardware prototype, and the test results are compared with the simulated performance for design verification.

  20. Power line monitoring system using fiber optic power supply

    NASA Astrophysics Data System (ADS)

    Tanaka, Yosuke; Shioda, Tatsutoshi; Kurokawa, Takashi; Oka, Junji; Ueta, Kazuyuki; Fukuoka, Toshiharu

    2009-05-01

    We propose a novel power-line-monitoring system using optical fibers for transmitting power as well as signal. The principle is experimentally confirmed with a system composed of a monitoring side with a 1.5-μm laser diode, transmission line of a single mode fiber, and a sensing side having an efficient photovoltaic (PV) cell, electrical junction sensor, and low power liquid crystal optical modulator (LCOM). The PV cell generates the electrical power in the sensing side with a conversion efficiency of 20%. The LCOM is driven with low power of less than 50 μW, modulates the laser light with a signal indicating the power line condition, and transmits the optical signal. The developed sensing unit produces an optical signal having an extinction ratio of 15 dB with low optical power of 1.8 mW. Five systems were in operation for two years, faithfully monitoring the oil pressure in electrical cables every 20 min without incident.

  1. AC and lightning performance of fiberglass crossarms aged in 115 kV transmission line

    SciTech Connect

    Grzybowski, S. . Dept. of Electrical and Computer Engineering); Jenkins, E.B. . Generation and Transmission Group)

    1993-10-01

    This paper presents the results of an investigation of the electrical performance of 115 kV transmission line fiberglass cross-arm used by Mississippi Power and Light Company. A transmission line fiberglass crossarm removed from service and companion cross-arms outdoors but not in service were examined. The evaluation of electrical performance was based on flashover voltage value at AC voltage and standard lightning impulses as well as under dry and wet conditions. The tests were performed in the Mississippi State University High Voltage Laboratory. The obtained flashover voltages show no large differences in electrical strength of fiberglass crossarms removed from service and those stored outdoors. The Added CFO voltage by fiberglass crossarm to the porcelain suspension insulators is presented versus the length of the fiberglass crossarm for dry and wet conditions.

  2. Ultrahigh-rate supercapacitors based on eletrochemically reduced graphene oxide for ac line-filtering.

    PubMed

    Sheng, Kaixuan; Sun, Yiqing; Li, Chun; Yuan, Wenjing; Shi, Gaoquan

    2012-01-01

    The recent boom in multifunction portable electronic equipments requires the development of compact and miniaturized electronic circuits with high efficiencies, low costs and long lasting time. For the operation of most line-powered electronics, alternating current (ac) line-filters are used to attenuate the leftover ac ripples on direct current (dc) voltage busses. Today, aluminum electrolytic capacitors (AECs) are widely applied for this purpose. However, they are usually the largest components in electronic circuits. Replacing AECs by more compact capacitors will have an immense impact on future electronic devices. Here, we report a double-layer capacitor based on three-dimensional (3D) interpenetrating graphene electrodes fabricated by electrochemical reduction of graphene oxide (ErGO-DLC). At 120-hertz, the ErGO-DLC exhibited a phase angle of -84 degrees, a specific capacitance of 283 microfaradays per centimeter square and a resistor-capacitor (RC) time constant of 1.35 milliseconds, making it capable of replacing AECs for the application of 120-hertz filtering. PMID:22355759

  3. Ultrahigh-rate supercapacitors based on eletrochemically reduced graphene oxide for ac line-filtering

    PubMed Central

    Sheng, Kaixuan; Sun, Yiqing; Li, Chun; Yuan, Wenjing; Shi, Gaoquan

    2012-01-01

    The recent boom in multifunction portable electronic equipments requires the development of compact and miniaturized electronic circuits with high efficiencies, low costs and long lasting time. For the operation of most line-powered electronics, alternating current (ac) line-filters are used to attenuate the leftover ac ripples on direct current (dc) voltage busses. Today, aluminum electrolytic capacitors (AECs) are widely applied for this purpose. However, they are usually the largest components in electronic circuits. Replacing AECs by more compact capacitors will have an immense impact on future electronic devices. Here, we report a double-layer capacitor based on three-dimensional (3D) interpenetrating graphene electrodes fabricated by electrochemical reduction of graphene oxide (ErGO-DLC). At 120-hertz, the ErGO-DLC exhibited a phase angle of −84 degrees, a specific capacitance of 283 microfaradays per centimeter square and a resistor-capacitor (RC) time constant of 1.35 milliseconds, making it capable of replacing AECs for the application of 120-hertz filtering. PMID:22355759

  4. Increased deposition of polychlorinated biphenyls (PCBs) under an AC high-voltage power line

    NASA Astrophysics Data System (ADS)

    Öberg, Tomas; Peltola, Pasi

    2009-12-01

    There is considerable public concern regarding the potential risks to health of electromagnetic fields in general and high-voltage power lines in particular. As epidemiological findings are not supported by a clearly defined mechanism of direct magnetic field interactions with the human body, potential indirect effects are of interest. It has been suggested that an increased exposure to chemical pollutants could occur near high-voltage power lines due to formation and deposition of charged aerosols. The current study reports empirical evidence that seems to support this hypothesis. The deposition of 18 congeners of polychlorinated biphenyls (PCBs) was studied by collecting samples of pine needles under a 400 kV AC power line and at reference sites in the vicinity. Compared to the reference sites, the average deposition of PCB congeners under the power line was almost double. This difference between the two groups of samples was statistically significant. While it is premature to draw any conclusions regarding the human exposure near high-voltage power lines, the issue deserves attention and further investigations.

  5. [Influence of D genome of wheat on expression of novel type spike branching in hybrid populations of 171ACS line].

    PubMed

    Alieva, A J; Aminov, N Kh

    2013-11-01

    A 171ACS line (AABBDD, 2n = 6x = 42) has been crossed with the tetra- (AABB and AAGG, 2n = 4x = 28) and octoploid (AAAABBGG, 2n = 8x = 56) wheat species without the D genome, as well as with hexaploid (AABBDD and AAGGDD, 2n = 6x = 42) wheat species and tetra- (AADD, 2n = 4x = 28) and hexaploid (AADDSS, 2n = 6x = 42) amphidiploids that have the D genome. The inheritance of a novel type of spike branching in these obtained hybrid populations F1-F3 was studied. According to the results of a morphogenetic analysis of hybrid populations derived from crossings between 171ACS and wheat species without the D genome, the novel type of branching was found to be controlled by a single recessive gene (although a phenotype of the 171ACS line gives a handle for a doubt about occurrence of the second gene) and the 171ACS line is a source of gene of the novel type branching. However, not a single branched spike plant was observed in hybrid populations that were produced by crosses of the 171ACS line with wheat species, as well as with amphidiploids that have the D genome. This result also experimentally confirmed the inhibitor effect of chromosomes of the D genome on the expression of the spike-branching trait. The appearance of branched spike forms, together with normal spiked plants in hybrid populations of the 171ACS line and T. araraticum Jakubz. (AAGG) or T. fungicidum Zhuk. (AAAABBGG) confirmed that, as opposed to the D genome, neither genome G nor genome B demonstrated the inhibition of the expression of the spike-branching trait. In conclusion, keeping in mind that branching is exhibited in hybrid progenies obtained from crosses between the 171ACS line and wheat species with AABB and AAGG genomes, it can be said that this gene belongs to the A genome. PMID:25470929

  6. [Influence of D genome of wheat on expression of novel type spike branching in hybrid populations of 171ACS line].

    PubMed

    2013-11-01

    A 171ACS line (AABBDD, 2n = 6x = 42) has been crossed with the tetra- (AABB and AAGG, 2n = 4x = 28) and octoploid (AAAABBGG, 2n = 8x = 56) wheat species without the D genome, as well as with hexaploid (AABBDD and AAGGDD, 2n = 6x = 42) wheat species and tetra- (AADD, 2n = 4x = 28) and hexaploid (AADDSS, 2n = 6x = 42) amphidiploids that have the D genome. The inheritance of a novel type of spike branching in these obtained hybrid populations F1-F3 was studied. According to the results of a morphogenetic analysis of hybrid populations derived from crossings between 171ACS and wheat species without the D genome, the novel type of branching was found to be controlled by a single recessive gene (although a phenotype of the 171ACS line gives a handle for a doubt about occurrence of the second gene) and the 171ACS line is a source of gene of the novel type branching. However, not a single branched spike plant was observed in hybrid populations that were produced by crosses of the 171ACS line with wheat species, as well as with amphidiploids that have the D genome. This result also experimentally confirmed the inhibitor effect of chromosomes of the D genome on the expression of the spike-branching trait. The appearance of branched spike forms, together with normal spiked plants in hybrid populations of the 171ACS line and T. araraticum Jakubz. (AAGG) or T. fungicidum Zhuk. (AAAABBGG) confirmed that, as opposed to the D genome, neither genome G nor genome B demonstrated the inhibition of the expression of the spike-branching trait. In conclusion, keeping in mind that branching is exhibited in hybrid progenies obtained from crosses between the 171ACS line and wheat species with AABB and AAGG genomes, it can be said that this gene belongs to the A genome. PMID:25508556

  7. Magnet power supply control of the NSLS VUV and x-ray storage rings transfer lines

    SciTech Connect

    Klein, J.D.; Ramamoorthy, S.; Singh, O.; Smith, J.D.

    1985-01-01

    The transfer lines for NSLS VUV and x-ray storage rings have been split. New power supplies have been incorporated with existing ones. The existing microprocessor system has been upgraded in order to control the additional functions. This system expands the input/output port of the microprocessor to an addressable serial/parallel link to each magnet power supply. The implementation of this system will be discussed.

  8. Chemically induced skin carcinogenesis in a transgenic mouse line (TG.AC) carrying a v-Ha-ras gene.

    PubMed

    Spalding, J W; Momma, J; Elwell, M R; Tennant, R W

    1993-07-01

    A transgenic mouse line (TG.AC) created in the FVB/N strain, carries a v-Ha-ras gene fused to a zeta-globin promoter gene. These trangenic mice have the properties of genetically initiated skin and have been shown to be sensitive to 12-O-tetradecanoylphorbol-13-acetate (TPA), a well-described promoter of skin papillomas in the two-stage mouse skin tumorigenesis model. It was of interest to determine whether the TG.AC mouse strain was also responsive to other known promoters. Groups of heterozygous or homozygous TG.AC mice were treated topically, 2x/week, for up to 20 weeks with benzoyl peroxide (BPO), 2-butanol peroxide (2-BUP), phenol (PH), acetic acid (AA), TPA and acetone (ACN), the vehicle control. Skin papillomas were induced in all groups treated with TPA, BPO and 2-BUP. Papillomas were observed in some treatment groups as early as 3 weeks. The relative activity of the promoters was TPA > 2-BUP > BPO > PH = AA = ACN. No papillomas were observed in any of the uninitiated FVB/N mice treated in a similar manner and which served as treatment control groups. Studies to determine the sensitivity of TG.AC mice to TPA, indicated that a total dose of 25-30 micrograms of TPA administered in 3 or 10 applications, was sufficient to induce an average incidence of 11-15 papillomas per mouse. The papilloma incidence continued to increase and was maintained up to 15 weeks after TPA treatment was terminated. The short latency period and high incidence of papilloma induction indicate that TG.AC mice have a high sensitivity to known skin promoters. The TG.AC line should prove to be a sensitive model for identifying putative tumor promoters or complete carcinogens. PMID:8330346

  9. [Mortality of people residing near electric power supply line with voltage of 500 kV].

    PubMed

    Gurvich, E B; Novokhatskaia, E A; Rubtsova, N B

    1996-01-01

    The epidemiologic study covered causes and levels of mortality in the settlement situated near electric power supply line (voltage is 500 kV). The work used retrospective cohort method adjusted for evaluation of mortality in general population. The study revealed no higher mortality risk with all the causes totally and with leading causal groups under influence of high frequency electromagnetic fields. However, higher relative mortality risk with leukemia and suicide appeared statistically insignificant. PMID:9019327

  10. In vitro cytotoxicity of Selol-loaded magnetic nanocapsules against neoplastic cell lines under AC magnetic field activation

    NASA Astrophysics Data System (ADS)

    Falqueiro, A. M.; Siqueira-Moura, M. P.; Jardim, D. R.; Primo, F. L.; Morais, P. C.; Mosiniewicz-Szablewska, E.; Suchocki, P.; Tedesco, A. C.

    2012-04-01

    The goals of this study are to evaluate invitro compatibility of magnetic nanomaterials and their therapeutic potential against cancer cells. Highly stable ionic magnetic fluid sample (maghemite, γ-Fe2O3) and Selol were incorporated into polymeric nanocapsules by nanoprecipitation method. The cytotoxic effect of Selol-loaded magnetic nanocapsules was assessed on murine melanoma (B16-F10) and oral squamous cell carcinoma (OSCC) cell lines following AC magnetic field application. The influence of different nanocapsules on cell viability was investigated by colorimetric MTT 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide assay. In the absence of AC magnetic field Selol-loaded magnetic nanocapsules, containing 100 µg/mL Selol plus 5 × 1012 particle/mL, showed antitumoral activity of about 50% on B16-F10 melanoma cells while OSCC carcinoma cells demonstrated drug resistance at all concentrations of Selol and magnetic fluid (range of 100-500 µg/mL Selol and 5 × 1012-2.5 × 1013 particle/mL). On the other hand, under AC applied fields (1 MHz and 40 Oe amplitude) B16-F10 cell viability was reduced down to 40.5% (±3.33) at the highest concentration of nanoencapsulated Selol. The major effect, however, was observed on OSCC cells since the cell viability drops down to about 33.3% (±0.38) under application of AC magnetic field. These findings clearly indicate that the Selol-loaded magnetic nanocapsules present different toxic effects on neoplastic cell lines. Further, the cytotoxic effect was maximized under AC magnetic field application on OSCC, which emphasizes the effectiveness of the magnetohyperthermia approach.

  11. HST/ACS EMISSION LINE IMAGING OF LOW-REDSHIFT 3CR RADIO GALAXIES. I. THE DATA

    SciTech Connect

    Tremblay, Grant R.; Chiaberge, Marco; Sparks, William B.; Macchetto, F. Duccio; Baum, Stefi A.; Axon, David J.; Noel-Storr, Jacob; O'Dea, Christopher P.; Allen, Mark G.; Capetti, Alessandro; Floyd, David J. E.; Miley, George K.; Perlman, Eric S.; Quillen, Alice C. E-mail: grant@astro.rit.edu

    2009-08-01

    We present 19 nearby (z < 0.3) 3CR radio galaxies imaged at low and high excitation as part of a Cycle 15 Hubble Space Telescope (HST) snapshot survey with the Advanced Camera for Surveys (ACS). These images consist of exposures of the H{alpha} (6563 A, plus [N II] contamination) and [O III]{lambda}5007 emission lines using narrowband linear ramp filters adjusted according to the redshift of the target. To facilitate continuum subtraction, a single-pointing 60 s line-free exposure was taken with a mediumband filter appropriate for the target's redshift. We discuss the steps taken to reduce these images independently of the automated recalibration pipeline so as to use more recent ACS flat-field data as well as to better reject cosmic rays. We describe the method used to produce continuum-free (pure line-emission) images, and present these images along with qualitative descriptions of the narrow-line region morphologies we observe. We present H{alpha}+[N II] and [O III] line fluxes from aperture photometry, finding the values to fall expectedly on the redshift-luminosity trend from a past HST/WFPC2 emission line study of a larger, generally higher redshift subset of the 3CR. We also find expected trends between emission line luminosity and total radio power, as well as a positive correlation between the size of the emission line region and redshift. We discuss the associated interpretation of these results, and conclude with a summary of future work enabled by this data set.

  12. Production of mRNA from the cry1Ac transgene differs among Bollgard lines which correlates to the level of subsequent protein.

    PubMed

    Adamczyk, John J; Perera, Omaththage; Meredith, William R

    2009-02-01

    Commercial cultivars of Bollgard cotton, Gossypium hirsutum L., differ in the amount of expressed Cry1Ac protein. However, the plant-mechanism for which this occurs is still unknown. Using quantitative real-time polymerase chain reaction (qPCR), we developed a method to determine if differences in the overall level of Cry1Ac among Bollgard lines could be correlated to the mRNA transcripts. Our data shows that the cry1Ac mRNA transcript differs among Bollgard lines and are correlated with corresponding Cry1Ac protein levels. In addition, qPCR based methods can efficiently be employed to quantify Cry1Ac protein expression levels in transgenic cotton cultivars. We postulate that qPCR based methods could be successfully employed for quantifying expression levels of transgenes in plants carrying different Bt toxins. PMID:18594999

  13. Single and three-phase AC losses in HTS superconducting power transmission line prototype cables

    SciTech Connect

    Daney, D.E.; Boenig, H.J.; Maley, M.P.; Coulter, J.Y.; Fleshler, S.

    1997-11-01

    AC losses in two, one-meter-long lengths of HTS prototype multi-strand conductors (PMC`s) are measured with a temperature-difference calorimeter. Both single-phase and three-phase losses are examined with ac currents up to 1,000 A rms. The calorimeter, designed specifically for these measurements, has a precision of 1 mW. PMC {number_sign}1 has two helically-wound, non-insulated layers of HTS tape (19 tapes per layer), each layer wrapped with opposite pitch. PMC {number_sign}2 is identical except for insulation between the layers. The measured ac losses show no significant effect of interlayer insulation and depend on about the third power of the current--a result in agreement with the Bean-Norris model adapted to the double-helix configuration. The three-phase losses are a factor of two higher than those exhibited by a single isolated conductor, indicating a significant interaction between phases.

  14. 3-V Solid-State Flexible Supercapacitors with Ionic-Liquid-Based Polymer Gel Electrolyte for AC Line Filtering.

    PubMed

    Kang, Yu Jin; Yoo, Yongju; Kim, Woong

    2016-06-01

    State-of-the-art solid-state flexible supercapacitors with sufficiently fast response speed for AC line filtering application suffer from limited energy density. One of the main causes of the low energy density is the low cell voltage (1 V), which is limited by aqueous-solution-based gel electrolytes. In this work, we demonstrate for the first time a 3-V flexible supercapacitor for AC line filtering based on an ionic-liquid-based polymer gel electrolyte and carbon nanotube electrode material. The flexible supercapacitor exhibits an areal energy density that is more than 20 times higher than that of the previously demonstrated 1-V flexible supercapacitor (0.66 vs 0.03 μWh/cm(2)) while maintaining excellent capacitive behavior at 120 Hz. The supercapacitor shows a maximum areal power density of 1.5 W/cm(2) and a time constant of 1 ms. The improvement of the cell voltage while maintaining the fast-response capability greatly improves the potential of supercapacitors for high-frequency applications in wearable and/or portable electronics. PMID:27167760

  15. A Transmission Renewal Planning Method using Supply-end Reserves and Line Flow Sensitivities

    NASA Astrophysics Data System (ADS)

    Ueda, Keisuke; Takamizawa, Yu; Iwamoto, Shinichi; Kato, Yoshinori; Shimazu, Masayuki

    With the high economic growth era until 1990s, the power demand increased sharply year by year. Therefore, the electric power utilities installed many electric power facilities along with the predicted demand. However, in recent years, fewer infrastructures have been installed because electric power demand growth is saturated due to low economic growth. Therefore, in electric power facilities planning, it has been necessary to form a rational renewal planning which also considers social influence factors such as the construction quantity. In this paper, we propose a new transmission renewal planning method using Supply-end Reserves and Line Flow Sensitivities. We carry out simulations for the IEEJ EAST 10-machine -O/V model system and determine the transmission planning priority order to confirm the validity of the proposed method.

  16. Electrical Experiments. VT-214-12-2. Part II. A-C Across the Line Control.

    ERIC Educational Resources Information Center

    Connecticut State Dept. of Education, Hartford. Div. of Vocational Education.

    Designed for high school electronics students, this second document in a series of six electrical learning activity packages focuses on alternating current across-the-line control. An introductory section gives the objective for the activities, an introduction, and an outline of the content. The remainder of the activity book is comprised of…

  17. Environmental Assessment and Finding of No Significant Impact: Sunrise II Water Supply Line

    SciTech Connect

    N /A

    2002-10-09

    Sunrise Power Company, LLC (Sunrise), has planned the modification of an existing power plant project to increase its generation capacity by 265 megawatts by 2003. The initial Sunrise facility was constructed in accordance with a license issued by the California Energy Commission (CEC) on December 6, 2000 and brought 320 MW of much needed power to commercial operation in June 2001. The Governor of the State of California issued recent Executive Orders to provide for emergency permit streamlining of projects that can help alleviate the current California energy crisis. Specifically, Executive Order D-25-01 directed the CEC to expedite processing amendments such as the Sunrise II modification that would increase generating capacity from 320 MW to 585 MW by summer 2003. As part of the modification, an approximately 15.3 mile water line will be installed. Additionally, improvements to West Kern Water District's (WKWD) Pumping Station ''B'', located on DOE land, will occur. Sunrise has requested a right-of-way grant for the construction of the water supply line on U.S. Bureau of Land Management (BLM) and DOE lands. Pursuant to the requirements of the National Environmental Policy Act of 1969 (NEPA), as amended, the potential impacts of the proposed action were analyzed in an Environmental Assessment (EA-1434) with the BLM acting as lead agency. Based on the analysis of the potential environmental impacts contained in the Environmental Assessment (EA), BLM has determined that significant impacts are not expected and an environmental impact statement is not required. The DOE, acting as a cooperating agency, has adopted the BLM's EA and is consequently issuing this Finding of No Significant Impact.

  18. 77 FR 5055 - Certain Lined Paper School Supplies From China, India, and Indonesia; Scheduling of Full Five...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... reviews were such that full reviews pursuant to section 751(c)(5) of the Act should proceed (76 FR 72213... took effect on November 7, 2011. See 76 FR 61937 (Oct. 6, 2011) and the newly revised Commission's... COMMISSION Certain Lined Paper School Supplies From China, India, and Indonesia; Scheduling of Full...

  19. Correction: BTI-Tnao38, a new cell line derived from Trichoplusia ni, is permissive for AcMNPV infection and produces high levels of recombinant proteins.

    PubMed

    Hashimoto, Yoshi; Zhang, Sheng; Zhang, Shiying; Chen, Yun-Ru; Blissard, Gary W

    2012-01-01

    After publication we discovered an error in the identification of the origin of the cell line reported in our article in BMC Biotechnology (2010, 10:50), entitled "Ao38, a new cell line from eggs of the black witch moth, Ascalapha odorata (Lepidoptera: Noctuidae), is permissive for AcMNPV infection and produces high levels of recombinant proteins". Upon analysis of primary A. odorata cultures, we found that they were contaminated with cells of Trichoplusia ni origin. The origin of the Ao38 cell line was determined as T. ni using three marker genes and the Ao38 cell line was renamed BTI-Tnao38. References to the origin of the cell line as Ascalapha odorata should be replaced with "a cell line of Trichoplusia ni origin". The absence of TNCL virus detection in the BTI-Tnao38 (Ao38) cell line was confirmed using a highly sensitive RT-PCR protocol capable of detecting TNCL virus RNA at approximately 0.018 copies/cell. Because of these observations, we have revised the title of the original article to "Correction: BTI-Tnao38, a new cell line derived from Trichoplusia ni, is permissive for AcMNPV infection and produces high levels of recombinant proteins" and two additional authors were added to reflect their contributions to the analysis of this cell line. PMID:22531032

  20. Computational Analysis of an LOx Supply Line System of an Liquid Rocket Engine

    NASA Astrophysics Data System (ADS)

    Moon, Insang; Moon, Il Yoon; Lee, Soo Yong

    2009-12-01

    A computational fluid analysis was performed on an LOx line system of a liquid rocket engine. The model was created with 3D CAD and imbedded to the 3D CFD program. Before the full scale analysis on the system was carried out, each components with simplified models was analyzed to save time and cost. As a result, the inlet pressure of the gas generator should be compensated with a certain device unless the inlet pressure of the line system is sufficiently high. The flow pattern of the exit of the system was dependant upon the location of the orifice as well as the size. As a whole the line system analyzed met the requirements, and will be tested and confirmed after being manufactured.

  1. Power supply

    DOEpatents

    Yakymyshyn, Christopher Paul; Hamilton, Pamela Jane; Brubaker, Michael Allen

    2007-12-04

    A modular, low weight impedance dropping power supply with battery backup is disclosed that can be connected to a high voltage AC source and provide electrical power at a lower voltage. The design can be scaled over a wide range of input voltages and over a wide range of output voltages and delivered power.

  2. Water-supply potential from an asphalt-lined catchment near Holualoa Kona, Hawaii

    USGS Publications Warehouse

    Chinn, Salwyn S.W.

    1965-01-01

    The Jenkins-Whitesburg area includes approximately 250 square miles In Letcher and Pike Counties in the southeastern part of the Eastern Coal Field. In this area ground water is the principal source of water for nearly all rural families, most public supplies, several coal mines and coal processing plants, and one bottling plant. The major aquifers in the Jenkins-Whitesburg area are the Breathitt and Lee Formations of Pennsylvanian age. Other aquifers range in age from Devonian to Quaternary but are not important in this area because they occur at great depth or yield little or no water. The Breathitt Formation occurs throughout the area except along the crest and slopes of Pine Mountain and where it is covered by unconsolidated material of Quaternary age. The Breathitt Formation consists of shale, sandstone, and lesser amounts of coal and associated underclay. The yield of wells penetrating the Breathitt Formation ranges from less than 1 to 330 gallons per minute. Well yield is controlled by the type and depth of well, character of the aquifer, and topography of the well site. Generally, deep wells drilled in valleys of perennial streams offer the best potential for high yields. Although enough water for a minimum domestic supply (more than 100 gallons per day) may be obtained from shale, all high-yielding wells probably obtain water from vertical joints and from bedding planes which are best developed in sandstone. About 13 percent of the wells inventoried in the Breathitt Formation failed to supply enough water for a minimum domestic supply. Most of these are shallow dug wells or drilled wells on hillsides or hilltops. Abandoned coal mines are utilized as large infiltration galleries and furnish part of the water for several public supplies. The chemical quality of water from the Breathitt Formation varies considerably from place to place, but the water generally is acceptable for most domestic and industrial uses. Most water is a calcium magnesium bicarbonate

  3. The Impact of On-line Searching on Document Supply Services at Individual Libraries

    NASA Astrophysics Data System (ADS)

    Hosono, Kimio; Tanaka, Isao; Fukazawa, Yoshiko

    As use of on-line searching services has progressed in libraries, requests on primary materials have increased much more than before. For the purpose of clarifying this trend and countermeasures against it a survey by questionnaire was conducted in 1985. The respondants from totally 112 libraries are as follows ; 60 industrial libraries, 41 academic libraries and 11 libraries of research institutes and laboratories. It was shown that industrial libraries have received more requests on primary materials mostly resulting from on-line searching while the requests have not increased remarkably in academic libraries. Regardless the type of libraries, almost all libraries can not fully meet the requests with their own collection so that industrial libraries have to rely on external information services and academic libraries utilize interlibrary loan system. Requests are sent via on-line from industrial libraries, and by mail from academic libraries. In fact, any-libraries are not likely to review their material-collecting policy. Therefore it is urgent to establish the system which enables use of external information services or interlibrary loan system more than ever.

  4. Development of an in-line filter to prevent intrusion of NO2 toxic vapors into A/C systems

    NASA Technical Reports Server (NTRS)

    Meneghelli, Barry; Mcnulty, R. J.; Springer, Mike; Lueck, Dale E.

    1995-01-01

    The hypergolic propellant nitrogen tetroxide (N2O4 or NTO) is routinely used in spacecraft launched at Kennedy Space Center (KSC) and Cape Canaveral Air Station (CCAS). In the case of a catastrophic failure of the spacecraft, there would be a release of the unspent propellant in the form of a toxic cloud. Inhalation of this material at downwind concentrations which may be as high as 20 parts per million (ppm) for 30 minutes in duration, may produce irritation to the eyes, nose and respiratory tract. Studies at both KSC and CCAS have shown that the indoor concentrations of N2O4 during a toxic release may range from 1 to 15 ppm and depend on the air change rate (ACR) for a particular building and whether or not the air conditioning (A/C) system has been shut down or left in an operating mode. This project was initiated in order to assess how current A/C systems could be easily modified to prevent personnel from being exposed to toxic vapors. A sample system has been constructed to test the ability of several types of filter material to capture the N2O4 vapors prior to their infiltration into the A/C system. Test results will be presented which compare the efficiencies of standard A/C filters, water wash systems, and chemically impregnated filter material in taking toxic vapors out of the incoming air stream.

  5. Combustor oscillation attenuation via the control of fuel-supply line dynamics

    DOEpatents

    Richards, G.A.; Gemmen, R.S.

    1998-09-22

    Combustion oscillation control in combustion systems using hydrocarbon fuels is provided by acoustically tuning a fuel-delivery line to a desired phase of the combustion oscillations for providing a pulse of a fuel-rich region at the oscillating flame front at each time when the oscillation produced pressure in the combustion chamber is in a low pressure phase. The additional heat release produced by burning such fuel-rich regions during low combustion chamber pressure effectively attenuates the combustion oscillations to a selected value. 9 figs.

  6. Combustor oscillation attenuation via the control of fuel-supply line dynamics

    DOEpatents

    Richards, George A.; Gemmen, Randall S.

    1998-01-01

    Combustion oscillation control in combustion systems using hydrocarbon fuels is provided by acoustically tuning a fuel-delivery line to a desired phase of the combustion oscillations for providing a pulse of a fuel-rich region at the oscillating flame front at each time when the oscillation produced pressure in the combustion chamber is in a low pressure phase. The additional heat release produced by burning such fuel-rich regions during low combustion chamber pressure effectively attenuates the combustion oscillations to a selected value.

  7. Corrosion response of downhole steam generator assembly and instrumentation and supply line tubings at Long Beach field test

    SciTech Connect

    Weirick, L.J.

    1983-07-01

    Three families of metals were used to make the non-combustor components for Sandia's downhole steam generator assembly and supply and instrumentation lines. These three families were: first, plain carbon steel (API Grade J 55); second, austenitic stainless steels (316 and 310); and third, a nickel-base superalloy (Inconel 600). The metals in all three of these families were found to be deficient in their corrosion response. J 55 exhibited minimal to severe general corrosion (rusting). The austenitic stainless steels pitted and cracked. Inconel 600 showed both severe pitting and some intergranular attack. For the most part, these materials were found to be unsuitable for extended life in a downhole steam generator. It is recommended that Inconel 625 be used in future systems where a moderate strength material is specified and Inconel 718 be considered where a high strength material is necessary. 11 references, 45 figures, 5 tables.

  8. Composite rod insulators for ac power lines; Electrical performance of various designs at a coastal testing station

    SciTech Connect

    Houlgate, R.G.; Swift, D.A. )

    1990-10-01

    The electrical performance of thirty-six composite insulators - of four commercial types for each AC system level of 34.5 kV, 230 kV and 500 kV - has been determined at the CEGB insulator testing station, Brighton, England. The weathershed materials were epoxy-resin, ethylene propylene rubber and silicone rubber; half of the 230 kV insulators had no stress rings. Surface leakage current was recorded for surge levels of 25 mA, 150 mA and 500 mA; a special technique was developed to obtain the flashover statistics of the 500 kV insulators, thereby enabling performance of the composite insulator to be quantified relative to that of a string of cap and pin porcelain insulators of anti-fog design, the deterioration of the insulators was observed by making regular visual inspections. The practical consequences of the findings and the causes of the degradation are discussed.

  9. World Bank Development Sector Adjustment Operation Life Line to Nigerian Universities: Impact on Information Demand and Supply in the University of Agriculture, Makurdi Library.

    ERIC Educational Resources Information Center

    Ozowa, Vincent Nnamdi

    1995-01-01

    Provides an overview of the rationale behind the World Bank credit line to Nigerian universities and examines the impact of the credit facility on the information demand and supply in the University of Agriculture, Makurdi Library (Nigeria). Discusses problems, such as poor quantity and quality of books and journals, lack of equipment, and lack of…

  10. 31P-nuclear magnetic resonance spectroscopy in vivo of six human melanoma xenograft lines: tumour bioenergetic status and blood supply.

    PubMed Central

    Lyng, H.; Olsen, D. R.; Southon, T. E.; Rofstad, E. K.

    1993-01-01

    Six human melanoma xenograft lines grown s.c. in BALB/c-nu/nu mice were subjected to 31P-nuclear magnetic resonance (31P-NMR) spectroscopy in vivo. The following resonances were detected: phosphomonoesters (PME), inorganic phosphate (Pi), phosphodiesters (PDE), phosphocreatine (PCr) and nucleoside triphosphate gamma, alpha and beta (NTP gamma, alpha and beta). The main purpose of the work was to search for possible relationships between 31P-NMR resonance ratios and tumour pH on the one hand and blood supply per viable tumour cell on the other. The latter parameter was measured by using the 86Rb uptake method. Tumour bioenergetic status [the (PCr + NTP beta)/Pi resonance ratio], tumour pH and blood supply per viable tumour cell decreased with increasing tumour volume for five of the six xenograft lines. The decrease in tumour bioenergetic status was due to a decrease in the (PCr + NTP beta)/total resonance ratio as well as an increase in the Pi/total resonance ratio. The decrease in the (PCr + NTP beta)/total resonance ratio was mainly a consequence of a decrease in the PCr/total resonance ratio for two lines and mainly a consequence of a decrease in the NTP beta/total resonance ratio for three lines. The magnitude of the decrease in the (PCr + NTP beta)/total resonance ratio and the magnitude of the decrease in tumour pH were correlated to the magnitude of the decrease in blood supply per viable tumour cell. Tumour pH decreased with decreasing tumour bioenergetic status, and the magnitude of this decrease was larger for the tumour lines showing a high than for those showing a low blood supply per viable tumour cell. No correlations across the tumour lines were found between tumour pH and tumour bioenergetic status or any other resonance ratio on the one hand and blood supply per viable tumour cell on the other. The differences in the 31P-NMR spectrum between the tumour lines were probably caused by differences in the intrinsic biochemical properties of the tumour

  11. Dietary quinic acid supplied as the nutritional supplement AIO + AC-11® leads to induction of micromolar levels of nicotinamide and tryptophan in the urine.

    PubMed

    Pero, Ronald W; Lund, Harald

    2011-06-01

    Hippuric acid is synthesized and produced primarily by the gastrointestinal (GI) microflora. However, there is no known health benefit for hippuric acid except its catabolic conjugation of benzene-type compounds via glycine and subsequent excretion in the urine. For years the GI tract microflora were known to metabolize quinic acid to hippuric acid. Recently it was also proposed that DNA repair was strongly enhanced by quinic acid. In order to explain these quinic acid effects, Pero and colleagues have examined whether tryptophan and nicotinamide were also enhanced by quinic acid levels in urine. They were indeed, and so another study was designed using a natural supplement source of quinic acid called AIO + AC-11®, and then the effects of intervention were measured after only 21 days. It was possible to show profound increases in quinic acid that were again paralleled by increases in tryptophan and nicotinamide urinary levels. Because the high pressure liquid chromatography (HPLC) methods differed greatly between the two studies, differences in chemical analyses probably did not contribute to the data base. PMID:21104945

  12. 76 FR 45851 - Certain Lined Paper School Supplies From China, India, and Indonesia-Institution of Five-Year...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-01

    ... part 207), as most recently amended at 74 FR 2847 (January 16, 2009). \\1\\ No response to this request... supplies from China, India, and Indonesia (71 FR 56949). On April 14, 2011, Commerce amended in part the antidumping duty order on subject imports from India (76 FR 20954). The Commission is conducting reviews...

  13. Booster main magnet power supply, present operation and potential future upgrades

    SciTech Connect

    Bajon, E.; Bannon, M.; Marneris, I.; Danowski, G.; Sandberg, J.; Savatteri, S.

    2011-03-28

    The Brookhaven Booster Main Magnet Power Supply (MMPS) is a 24 pulse thyristor control supply, rated at 5500 Amps, +/-2000 Volts, or 3000 Amps, +/-6000 Volts. The power supply is fed directly from the power utility and the peak magnet power is 18 MWatts. This peak power is seen directly at the incoming ac line. This power supply has been in operation for the last 18 years. This paper will describe the present topology and operation of the power supply, the feedback control system and the different modes of operation of the power supply. Since the power supply has been in operation for the last 18 years, upgrading this power supply is essential. A new power supply topology has been studied where energy is stored in capacitor banks. DC to DC converters are used to convert the dc voltage stored in the capacitor banks to pulsed DC voltage into the magnet load. This enables the average incoming power from the ac line to be constant while the peak magnet power is pulsed to +/- 18 MWatts. Simulations and waveforms of this power supply will be presented.

  14. Voltage controller/current limiter for ac

    NASA Technical Reports Server (NTRS)

    Wu, T. T.

    1980-01-01

    Circuit protects ac power systems for overload failures, limits power surge and short-circuit currents to 150 percent of steady state level, regulates ac output voltage, and soft starts loads. Limiter generates dc error signal in response to line fluctuations and dumps power when overload is reached. Device is inserted between ac source and load.

  15. Effects of water management practices on residue decomposition and degradation of Cry1Ac protein from crop-wild Bt rice hybrids and parental lines during winter fallow season.

    PubMed

    Xiao, Manqiu; Dong, Shanshan; Li, Zhaolei; Tang, Xu; Chen, Yi; Yang, Shengmao; Wu, Chunyan; Ouyang, Dongxin; Fang, Changming; Song, Zhiping

    2015-12-01

    Rice is the staple diet of over half of the world's population and Bacillus thuringiensis (Bt) rice expressing insecticidal Cry proteins is ready for deployment. An assessment of the potential impact of Bt rice on the soil ecosystem under varied field management practices is urgently required. We used litter bags to assess the residue (leaves, stems and roots) decomposition dynamics of two transgenic rice lines (Kefeng6 and Kefeng8) containing stacked genes from Bt and sck (a modified CpTI gene encoding a cowpea trypsin inhibitor) (Bt/CpTI), a non-transgenic rice near-isoline (Minghui86), wild rice (Oryza rufipogon) and crop-wild Bt rice hybrid under contrasting conditions (drainage or continuous flooding) in the field. No significant difference was detected in the remaining mass, total C and total N among cultivars under aerobic conditions, whereas significant differences in the remaining mass and total C were detected between Kefeng6 and Kefeng8 and Minghui86 under the flooded condition. A higher decomposition rate constant (km) was measured under the flooded condition compared with the aerobic condition for leaf residues, whereas the reverse was observed for root residues. The enzyme-linked immunosorbent assay (ELISA), which was used to monitor the changes in the Cry1Ac protein in Bt rice residues, indicated that (1) the degradation of the Cry1Ac protein under both conditions best fit first-order kinetics, and the predicted DT50 (50% degradation time) of the Cry1Ac protein ranged from 3.6 to 32.5 days; (2) the Cry1Ac protein in the residue degraded relatively faster under aerobic conditions; and (3) by the end of the study (~154 days), the protein was present at a low concentration in the remaining residues under both conditions. The degradation rate constant was negatively correlated with the initial carbon content and positively correlated with the initial Cry1Ac protein concentration, but it was only correlated with the mass decomposition rate constants under

  16. Lines

    ERIC Educational Resources Information Center

    Mires, Peter B.

    2006-01-01

    National Geography Standards for the middle school years generally stress the teaching of latitude and longitude. There are many creative ways to explain the great grid that encircles our planet, but the author has found that students in his college-level geography courses especially enjoy human-interest stories associated with lines of latitude…

  17. AC losses in BiPbSrCaCuO-2223/Ag multifilamentary tapes in conditions similar to those in superconducting transmission lines

    NASA Astrophysics Data System (ADS)

    Majoros, M.; Glowacki, B. A.; Campbell, A. M.; Han, Z.; Vase, P.

    1998-12-01

    Transport AC losses in BiPbSrCaCuO-2223/Ag multifilamentary tape with 19 filaments were measured. The sample was 1.05 m long, wound in form of a helix with a gap between the tapes comparable with the tape width. Two different types of potential leads-tape following, axis following-with taps positioned in the centre of the tape were mounted on inner as well as outer surface of the helical sample. AC losses were measured at power frequencies by an electrical method using a lock-in nanovoltmeter. The influence of potential wires arrangement and the potential taps position on measured AC loss level and its frequency dependence was analysed.

  18. Production of mRNA from the cry1Ac Transgene differs among Bollgard® lines which correlates to the level of subsequent protein.

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Commercial cultivars of Bollgard® cotton, Gossypium hirsutum L., differ in the amount of expressed Cry1Ac protein. However, the plant-mechanism for which this occurs is still unknown. Using quantitative real-time polymerase chain reaction (qPCR), we developed a method to determine if differences in...

  19. Penumatic-power supply

    NASA Technical Reports Server (NTRS)

    Kramer, R. C.

    1981-01-01

    Portable compressed air supply has two or more outputs at pressures from 20 to 100 psi. Applications include operating production equipment, spraying paint and lubricants, and pressurizing refrigeration systems. Supply filters air from standard high-pressure line, reduces it to working pressure, and adds lubricant when required. Regulator supplies low-pressure air to output channels. On channel lines, vernier-control valves select output pressures.

  20. SELECTIVE SOURCE AC/DC POWER SUPPLY

    EPA Science Inventory

    This project will result in a prototype that will allow people and businesses to improve the efficiencies of photovoltaic products that they already own. The final prototype will be tested to quantify efficiency gain. This data will be analyzed to calculate the product’s pay...

  1. Association of maternal and nutrient supply line factors with DNA methylation at the imprinted IGF2/H19 locus in multiple tissues of newborn twins.

    PubMed

    Loke, Yuk Jing; Galati, John C; Morley, Ruth; Joo, Eric Ji-Hoon; Novakovic, Boris; Li, Xin; Weinrich, Blaise; Carson, Nicole; Ollikainen, Miina; Ng, Hong-Kiat; Andronikos, Roberta; Aziz, Nur Khairunnisa Abdul; Saffery, Richard; Craig, Jeffrey M

    2013-10-01

    Epigenetic events are crucial for early development, but can be influenced by environmental factors, potentially programming the genome for later adverse health outcomes. The insulin-like growth factor 2 (IGF2)/H19 locus is crucial for prenatal growth and the epigenetic state at this locus is environmentally labile. Recent studies have implicated maternal factors, including folate intake and smoking, in the regulation of DNA methylation at this locus, although data are often conflicting in the direction and magnitude of effect. Most studies have focused on single tissues and on one or two differentially-methylated regions (DMRs) regulating IGF2/H19 expression. In this study, we investigated the relationship between multiple shared and non-shared gestational/maternal factors and DNA methylation at four IGF2/H19 DMRs in five newborn cell types from 67 pairs of monozygotic and 49 pairs of dizygotic twins. Data on maternal and non-shared supply line factors were collected during the second and third trimesters of pregnancy and DNA methylation was measured via mass spectrometry using Sequenom MassArray EpiTyper analysis. Our exploratory approach showed that the site of umbilical cord insertion into the placenta in monochorionic twins has the strongest positive association with methylation in all IGF2/H19 DMRs (p<0.05). Further, evidence for tissue- and locus-specific effects were observed, emphasizing that responsiveness to environmental exposures in utero cannot be generalized across genes and tissues, potentially accounting for the lack of consistency in previous findings. Such complexity in responsiveness to environmental exposures in utero has implications for all epigenetic studies investigating the developmental origins of health and disease. PMID:23917818

  2. Cooling Floor AC Systems

    NASA Astrophysics Data System (ADS)

    Jun, Lu; Hao, Ding; Hong, Zhang; Ce, Gao Dian

    The present HVAC equipments for the residential buildings in the Hot-summer-and-Cold-winter climate region are still at a high energy consuming level. So that the high efficiency HVAC system is an urgently need for achieving the preset government energy saving goal. With its advantage of highly sanitary, highly comfortable and uniform of temperature field, the hot-water resource floor radiation heating system has been widely accepted. This paper has put forward a new way in air-conditioning, which combines the fresh-air supply unit and such floor radiation system for the dehumidification and cooling in summer or heating in winter. By analyze its advantages and limitations, we found that this so called Cooling/ Heating Floor AC System can improve the IAQ of residential building while keep high efficiency quality. We also recommend a methodology for the HVAC system designing, which will ensure the reduction of energy cost of users.

  3. AC resistance measuring instrument

    DOEpatents

    Hof, P.J.

    1983-10-04

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.

  4. AC Resistance measuring instrument

    DOEpatents

    Hof, Peter J.

    1983-01-01

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument.

  5. Direct current uninterruptible power supply method and system

    DOEpatents

    Sinha, Gautam

    2003-12-02

    A method and system are described for providing a direct current (DC) uninterruptible power supply with the method including, for example: continuously supplying fuel to a turbine; converting mechanical power from the turbine into alternating current (AC) electrical power; converting the AC electrical power to DC power within a predetermined voltage level range; supplying the DC power to a load; and maintaining a DC load voltage within the predetermined voltage level range by adjusting the amount of fuel supplied to the turbine.

  6. Supply Management.

    ERIC Educational Resources Information Center

    Marine Corps Inst., Washington, DC.

    Developed as part of the Marine Corps Institute (MCI) correspondence training program, this course on supply management is designed to provide the supply chief with an understanding of the fundamental functions of supply management as it applies to a supply office. Introductory materials include specific information for MCI students, a course…

  7. METALLICITIES OF EMISSION-LINE GALAXIES FROM HST ACS PEARS AND HST WFC3 ERS GRISM SPECTROSCOPY AT 0.6 < z < 2.4

    SciTech Connect

    Xia Lifang; Malhotra, Sangeeta; Rhoads, James; Cohen, Seth; Windhorst, Rogier A.; Pirzkal, Nor; Straughn, Amber; Finkelstein, Steven; Kuntschner, Harald; Kuemmel, Martin; Walsh, Jeremy; O'Connell, Robert

    2012-07-15

    Galaxies selected on the basis of their emission-line strength show low metallicities, regardless of their redshifts. We conclude this from a sample of faint galaxies at redshifts between 0.6 < z < 2.4, selected by their prominent emission lines in low-resolution grism spectra in the optical with the Advanced Camera for Surveys on the Hubble Space Telescope and in the near-infrared using Wide-Field Camera 3. Using a sample of 11 emission-line galaxies at 0.6 < z < 2.4 with luminosities of -22 {approx}< M{sub B} {approx}< -19 which have [O II], H{beta}, and [O III] line flux measurements from the combination of two grism spectral surveys, we use the R23 method to derive the gas-phase oxygen abundances: 7.5 < 12 + log (O/H) < 8.5. The galaxy stellar masses are derived using Bayesian-based Markov Chain Monte Carlo ({pi}MC{sup 2}) fitting of their spectral energy distribution, and span the mass range 8.1 < log (M{sub *}/M{sub Sun} ) < 10.1. These galaxies show mass-metallicity (M-Z) and luminosity-metallicity (L-Z) relations, which are offset by -0.6 dex in metallicity at given absolute magnitude and stellar mass relative to the local Sloan Digital Sky Survey galaxies, as well as continuum-selected DEEP2 samples at similar redshifts. The emission-line-selected galaxies most resemble the local 'green peas' galaxies and Ly{alpha} galaxies at z {approx_equal} 0.3 and z {approx_equal} 2.3 in the M-Z and L-Z relations and their morphologies. The G - M{sub 20} morphology analysis shows that 10 out of 11 show disturbed morphology, even as the star-forming regions are compact. These galaxies may be intrinsically metal poor, being at early stages of formation, or the low metallicities may be due to gas infall and accretion due to mergers.

  8. Effect of hepatitis B virus infection on trophoblast cell line (HTR-8/SVneo) and choriocarcinoma cell line (JEG3) is linked to CD133-2 (AC141) expression.

    PubMed

    Cui, Hong; Chen, Jing; Na, Quan

    2016-01-01

    Mother-to-infant transmission of hepatitis B virus (HBV) plays an important role in the chronic carrier state in China. In our studies, the response of trophoblast cell and choriocarcinoma cell to HBV infection regarding the expression of CD133-2 (AC141) was evaluated. Western blot and RT-PCR showed that a high level of CD133-2 protein and mRNA in HTR-8/SVneo cells, but a low level in JEG-3 cells. Lower proliferation and mobility, and higher apoptosis were observed in HTR-8/SVneo cells and JEG-3-CD133-2(+) cells after HBV infection than those in HTR-8-CD133-2(-) cells and JEG-3 cells. Our main finding is that CD133-negative cells (HTR-8-CD133-2(-) and JEG-3) are prone to HBV infection. In the last, our data indicated that the activation of Smad signaling pathway and the induction of epithelial-mesenchymal transition (EMT) in CD133-negative cells after HBV infection. In summary, our study demonstrated that CD133 is a key factor that mediated HBV infection to trophoblast cell and choriocarcinoma cell. PMID:27508045

  9. Effect of hepatitis B virus infection on trophoblast cell line (HTR-8/SVneo) and choriocarcinoma cell line (JEG3) is linked to CD133-2 (AC141) expression

    PubMed Central

    Cui, Hong; Chen, Jing; Na, Quan

    2016-01-01

    Mother-to-infant transmission of hepatitis B virus (HBV) plays an important role in the chronic carrier state in China. In our studies, the response of trophoblast cell and choriocarcinoma cell to HBV infection regarding the expression of CD133-2 (AC141) was evaluated. Western blot and RT-PCR showed that a high level of CD133-2 protein and mRNA in HTR-8/SVneo cells, but a low level in JEG-3 cells. Lower proliferation and mobility, and higher apoptosis were observed in HTR-8/SVneo cells and JEG-3-CD133-2+ cells after HBV infection than those in HTR-8-CD133-2- cells and JEG-3 cells. Our main finding is that CD133-negative cells (HTR-8-CD133-2- and JEG-3) are prone to HBV infection. In the last, our data indicated that the activation of Smad signaling pathway and the induction of epithelial-mesenchymal transition (EMT) in CD133-negative cells after HBV infection. In summary, our study demonstrated that CD133 is a key factor that mediated HBV infection to trophoblast cell and choriocarcinoma cell. PMID:27508045

  10. Metallicities of Emission-Line Galaxies from HST ACS PEARS and HST WFC3 ERS Grism Spectroscopy at 0.6 is less than z is less than 2.4

    NASA Technical Reports Server (NTRS)

    Xia, Lifang; Malhotra, Sangetta; Rhoads, James; Pirzkal, Nor; Straughn, Amber; Finkelstein, Steven; Cohen, Seth; Kuntschner, Harald; Walsh, Jeremy; Windhorst, Rogier A.; O'Connell, Robert; Kuemmel, Martin

    2012-01-01

    Galaxies selected on the basis of their emission line strength. show low metallicities, regardless of their redshifts. We conclude this from a sample of faint galaxies at redshifts between 0.6 < z < 2.4, selected by their prominent emission lines in low resolution grism spectra in the optiCa.i with the Advanced Camera for Surveys (ACS) on the Hubble Space Telescope (HST) and in the near-infrared using Wide-Field Camera 3 (WFC3). Using a sample of 11 emission line galaxies (ELGs) at 0.6 < z < 2.4 with luminosities of -22 approx < MB approx -19 which have [OII], H-Beta, and [OIII] line flux measurements from the combination of two grism spectral surveys, we use the R23 method to derive the gas-phase oxygen abundances: 7.5 <12+log(0/H)<8.5. The galaxy stellar masses are derived using Bayesian based Markov Chain Monte Carlo (pi MC(exp 2)) fitting of their Spectral Energy Distribution (SED), and span the mass range 8.1 < log(M(stellar)/M(solar)) < 10.1. These galaxies show a mass-metal1icity (M-L) and Luminosity-Metallicity (LZ) relation, which is offset by -line selected galaxies most resemble the local "green peas" galaxies and Lyman-alpha galaxies at z approx = 0.3 and z approx = 2.3 in the M-Z and L-Z relations and their morphologies. The G - M(sub 20) morphology analysis shows that 10 out of 11 show disturbed morphology, even as the star-forming regions are compact. These galaxies may be intrinsically metal poor, being at early stages of formation, or the low metallicities may be due to gas infall and accretion due to mergers.

  11. ac-resistance-measuring instrument

    SciTech Connect

    Hof, P.J.

    1981-04-22

    An auto-ranging ac resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an ac excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance.

  12. ACS Quicklook PDF products

    NASA Astrophysics Data System (ADS)

    Suchkov, Anatoly

    1999-12-01

    This report details the features of the ACS quicklook PDF products produced by the HST data pipeline. The requirements closely follow the design of paper products recommended by the Data Quality Committee, with appropriate changes required to fully support ACS.

  13. UPS with input commutation between ac and dc sources of power

    SciTech Connect

    Severinsky, A.J.

    1993-08-31

    An uninterruptible power supply is described, said power supply comprising: AC input terminal means for receiving a first AC voltage from an AC power source; DC input terminal means for receiving a first DC voltage from a DC power source; AC output terminal means for connecting to a load; converter means for converting said first AC voltage to a second DC voltage across electrical charge storage means coupled to said converter means, said second DC voltage being larger than the maximum peak voltage of said first AC voltage and said first DC voltage; switching means coupled to said AC power source and said DC power source for selectively connecting said AC power source or said DC power source to said converter means; inverter means coupled to said electrical charge storage means for receiving said second DC voltage and inverting said second DC voltage to a second AC voltage, said second AC voltage being coupled to said AC output terminal means; and control means coupled to said switching means for controlling the operation of said switching means, said control means operating said switching means to connect said AC power source to said converter means only when said first AC voltage is within a predetermined range and operating to connect said DC power source to said converter means when said first AC voltage is outside of said range.

  14. System for automatically switching transformer coupled lines

    NASA Technical Reports Server (NTRS)

    Dwinell, W. S. (Inventor)

    1979-01-01

    A system is presented for automatically controlling transformer coupled alternating current electric lines. The secondary winding of each transformer is provided with a center tap. A switching circuit is connected to the center taps of a pair of secondary windings and includes a switch controller. An impedance is connected between the center taps of the opposite pair of secondary windings. The switching circuit has continuity when the AC lines are continuous and discontinuity with any disconnect of the AC lines. Normally open switching means are provided in at least one AC line. The switch controller automatically opens the switching means when the AC lines become separated.

  15. Advanced Vapor-Supply Manifold

    NASA Technical Reports Server (NTRS)

    Clark, I. O.; Debnam, William J., Jr.; Fripp, Archibald L., Jr.; Crouch, R. K.

    1986-01-01

    Advanced vapor-supply manifold solves problem of manifold purging. Design virtually eliminates dead gas volumes in manifold system. System incorporates special valve into manifold in way that leaks and contamination problems of previous systems, which use tees and three-port valves, are minimized or eliminated in both main manifold line and in supply line. Of considerable use in gas manifold systems where even small amounts of gaseous impurities constitute problem or where more than one gaseous material used in single system.

  16. Nursing Supplies

    MedlinePlus

    ... Stages Listen Español Text Size Email Print Share Nursing Supplies Page Content Article Body Throughout most of ... budget. (Nursing equipment also makes wonderful baby gifts.) Nursing Bras A well-made nursing bra that comfortably ...

  17. Power Supply

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Maxwell Laboratories capacitor charging power supply is the first commercial spinoff from the NASA CCDS program - a consortia of industries and government establishments to accelerate development of ground and space based commercial applications of NASA technology. The power supply transforms and conditions large voltages to charge capacitors used in x-ray sources, medical accelerators, etc. It is lighter, more reliable, more compact and efficient. Originally developed for space lasers, its commercial potential was soon recognized.

  18. Development of dielectric barrier discharging power supply

    NASA Astrophysics Data System (ADS)

    Gao, Yinghui; Liu, Kun; Fu, Rongyao; Sun, Yaohong; Yan, Ping

    2015-11-01

    Due to the demand of a dielectric barrier discharge power supply, a high voltage and high frequency AC power supply was designed and implemented. Its output voltage is standard or approximate standard sine waveform with the frequency range of 1 kHz to 50 kHz. The output voltage and output frequency can be adjusted individually. The maximum output power of the power supply is 2 kW. It can be operated through local or remote control. The power supply has been used in the dielectric barrier discharging research under different conditions.

  19. Power Supply Unit

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The Cuk DC to DC Switching Converter was developed by Caltech Professors, Slobodan Cuk and R. D. Middlebrook. The converter changes unsuitable dc voltage into one or more voltages suitable for powering electronic equipment; it can also be used in converting dc current to ac and vice versa. It was named one of the 100 most significant technical advances of 1979. The Cuk converter is more efficient than previous conversion devices, simpler, smaller, lighter, cheaper and highly reliable. The first application of the technology is in the Compucorp 685 word/data processor, manufactured by Compucorp. NASA waived title rights; Caltech granted exclusive license to the inventors, who in turn, transferred their rights to a company they founded called TESLA Company, which sublicenses the converter design and related technology to companies making power supplies for use in their own products.

  20. Voltage source ac-to-dc converters for high-power transmitters

    NASA Technical Reports Server (NTRS)

    Cormier, R.

    1990-01-01

    This work was done to optimize the design of the components used for the beam power supply, which is a component of the transmitters in the Deep Space Network (DSN). The major findings are: (1) the difference in regulation between a six-pulse and a twelve-pulse converter is at most 7 percent worse for the twelve-pulse converter; (2) the commutation overlap angle of a current source converter equals that of a voltage source converter with continuous line currents; (3) the sources of uncharacteristic harmonics are identified with SPICE simulation; (4) the use of an imperfect phase-shifting transformer for the twelve-pulse converter generates a harmonic at six times the line frequency; and (5) the assumptions usually made in analyzing converters can be relaxed with SPICE simulation. The results demonstrate the suitability of using SPICE simulation to obtain detailed performance predictions of ac-to-dc converters.

  1. High-frequency ac power distribution in Space Station

    NASA Technical Reports Server (NTRS)

    Tsai, Fu-Sheng; Lee, Fred C. Y.

    1990-01-01

    A utility-type 20-kHz ac power distribution system for the Space Station, employing resonant power-conversion techniques, is presented. The system converts raw dc voltage from photovoltaic cells or three-phase LF ac voltage from a solar dynamic generator into a regulated 20-kHz ac voltage for distribution among various loads. The results of EASY5 computer simulations of the local and global performance show that the system has fast response and good transient behavior. The ac bus voltage is effectively regulated using the phase-control scheme, which is demonstrated with both line and load variations. The feasibility of paralleling the driver-module outputs is illustrated with the driver modules synchronized and sharing a common feedback loop. An HF sinusoidal ac voltage is generated in the three-phase ac input case, when the driver modules are phased 120 deg away from one another and their outputs are connected in series.

  2. Microfabricated AC impedance sensor

    DOEpatents

    Krulevitch, Peter; Ackler, Harold D.; Becker, Frederick; Boser, Bernhard E.; Eldredge, Adam B.; Fuller, Christopher K.; Gascoyne, Peter R. C.; Hamilton, Julie K.; Swierkowski, Stefan P.; Wang, Xiao-Bo

    2002-01-01

    A microfabricated instrument for detecting and identifying cells and other particles based on alternating current (AC) impedance measurements. The microfabricated AC impedance sensor includes two critical elements: 1) a microfluidic chip, preferably of glass substrates, having at least one microchannel therein and with electrodes patterned on both substrates, and 2) electrical circuits that connect to the electrodes on the microfluidic chip and detect signals associated with particles traveling down the microchannels. These circuits enable multiple AC impedance measurements of individual particles at high throughput rates with sufficient resolution to identify different particle and cell types as appropriate for environmental detection and clinical diagnostic applications.

  3. Oxygen supplies in disaster management.

    PubMed

    Blakeman, Thomas C; Branson, Richard D

    2013-01-01

    Mass casualty events and disasters, both natural and human-generated, occur frequently around the world and can generate scores of injured or ill victims in need of resources. Of the available medical supplies, oxygen remains the critical consumable resource in disaster management. Strategic management of oxygen supplies in disaster scenarios remains a priority. Hospitals have large supplies of liquid oxygen and a supply of compressed gas oxygen cylinders that allow several days of reserve, but a large influx of patients from a disaster can strain these resources. Most backup liquid oxygen supplies are attached to the main liquid system and supply line. In the event of damage to the main system, the reserve supply is rendered useless. The Strategic National Stockpile supplies medications, medical supplies, and equipment to disaster areas, but it does not supply oxygen. Contracted vendors can deliver oxygen to alternate care facilities in disaster areas, in the form of concentrators, compressed gas cylinders, and liquid oxygen. Planning for oxygen needs following a disaster still presents a substantial challenge, but alternate care facilities have proven to be valuable in relieving pressure from the mass influx of patients into hospitals, especially for those on home oxygen who require only an electrical source to power their oxygen concentrator. PMID:23271827

  4. Power supply

    DOEpatents

    Hart, Edward J.; Leeman, James E.; MacDougall, Hugh R.; Marron, John J.; Smith, Calvin C.

    1976-01-01

    An electric power supply employs a striking means to initiate ferroelectric elements which provide electrical energy output which subsequently initiates an explosive charge which initiates a second ferroelectric current generator to deliver current to the coil of a magnetic field current generator, creating a magnetic field around the coil. Continued detonation effects compression of the magnetic field and subsequent generation and delivery of a large output current to appropriate output loads.

  5. AC magnetohydrodynamic microfluidic switch

    SciTech Connect

    Lemoff, A V; Lee, A P

    2000-03-02

    A microfluidic switch has been demonstrated using an AC Magnetohydrodynamic (MHD) pumping mechanism in which the Lorentz force is used to pump an electrolytic solution. By integrating two AC MHD pumps into different arms of a Y-shaped fluidic circuit, flow can be switched between the two arms. This type of switch can be used to produce complex fluidic routing, which may have multiple applications in {micro}TAS.

  6. ACS Symposium Support

    SciTech Connect

    Kenneth D. Jordan

    2010-02-20

    The funds from this DOE grant were used to help cover the travel costs of five students and postdoctoral fellows who attended a symposium on 'Hydration: From Clusters to Aqueous Solutions' held at the Fall 2007 American Chemical Society Meeting in Boston, MA, August 19-23. The Symposium was sponsored by the Physical Chemistry Division, ACS. The technical program for the meeting is available at http://phys-acs.org/fall2007.html.

  7. HIRFL-CSR power supply system

    NASA Astrophysics Data System (ADS)

    Gao, Daqing; Zhou, Zhongzu; Chen, Youxin; Wu, Rong; Shangguan, Jingbin; Bai, Zhen

    2001-12-01

    There are more than 200 power supplies will be employed in CSR power supply system. These power supplies provide DC and pulsed exciting current for all magnets in main ring (CSRm), experiment ring (CSRe), injection line of CSRm and RIB line. Six small-scale prototypes have been designed and made before formal manufacture. One thyristor rectifier pulsed converter was delivered to Lanzhou in January and all measurement has been finished in April. The result is satisfied.

  8. Teleconnected food supply shocks

    NASA Astrophysics Data System (ADS)

    Bren d'Amour, Christopher; Wenz, Leonie; Kalkuhl, Matthias; Steckel, Jan Christoph; Creutzig, Felix

    2016-03-01

    The 2008-2010 food crisis might have been a harbinger of fundamental climate-induced food crises with geopolitical implications. Heat-wave-induced yield losses in Russia and resulting export restrictions led to increases in market prices for wheat across the Middle East, likely contributing to the Arab Spring. With ongoing climate change, temperatures and temperature variability will rise, leading to higher uncertainty in yields for major nutritional crops. Here we investigate which countries are most vulnerable to teleconnected supply-shocks, i.e. where diets strongly rely on the import of wheat, maize, or rice, and where a large share of the population is living in poverty. We find that the Middle East is most sensitive to teleconnected supply shocks in wheat, Central America to supply shocks in maize, and Western Africa to supply shocks in rice. Weighing with poverty levels, Sub-Saharan Africa is most affected. Altogether, a simultaneous 10% reduction in exports of wheat, rice, and maize would reduce caloric intake of 55 million people living in poverty by about 5%. Export bans in major producing regions would put up to 200 million people below the poverty line at risk, 90% of which live in Sub-Saharan Africa. Our results suggest that a region-specific combination of national increases in agricultural productivity and diversification of trade partners and diets can effectively decrease future food security risks.

  9. Teleconnected food supply shocks

    NASA Astrophysics Data System (ADS)

    Bren d’Amour, Christopher; Wenz, Leonie; Kalkuhl, Matthias; Steckel, Jan Christoph; Creutzig, Felix

    2016-03-01

    The 2008–2010 food crisis might have been a harbinger of fundamental climate-induced food crises with geopolitical implications. Heat-wave-induced yield losses in Russia and resulting export restrictions led to increases in market prices for wheat across the Middle East, likely contributing to the Arab Spring. With ongoing climate change, temperatures and temperature variability will rise, leading to higher uncertainty in yields for major nutritional crops. Here we investigate which countries are most vulnerable to teleconnected supply-shocks, i.e. where diets strongly rely on the import of wheat, maize, or rice, and where a large share of the population is living in poverty. We find that the Middle East is most sensitive to teleconnected supply shocks in wheat, Central America to supply shocks in maize, and Western Africa to supply shocks in rice. Weighing with poverty levels, Sub-Saharan Africa is most affected. Altogether, a simultaneous 10% reduction in exports of wheat, rice, and maize would reduce caloric intake of 55 million people living in poverty by about 5%. Export bans in major producing regions would put up to 200 million people below the poverty line at risk, 90% of which live in Sub-Saharan Africa. Our results suggest that a region-specific combination of national increases in agricultural productivity and diversification of trade partners and diets can effectively decrease future food security risks.

  10. Reliability Estimates for Power Supplies

    SciTech Connect

    Lee C. Cadwallader; Peter I. Petersen

    2005-09-01

    Failure rates for large power supplies at a fusion facility are critical knowledge needed to estimate availability of the facility or to set priorties for repairs and spare components. A study of the "failure to operate on demand" and "failure to continue to operate" failure rates has been performed for the large power supplies at DIII-D, which provide power to the magnet coils, the neutral beam injectors, the electron cyclotron heating systems, and the fast wave systems. When one of the power supplies fails to operate, the research program has to be either temporarily changed or halted. If one of the power supplies for the toroidal or ohmic heating coils fails, the operations have to be suspended or the research is continued at de-rated parameters until a repair is completed. If one of the power supplies used in the auxiliary plasma heating systems fails the research is often temporarily changed until a repair is completed. The power supplies are operated remotely and repairs are only performed when the power supplies are off line, so that failure of a power supply does not cause any risk to personnel. The DIII-D Trouble Report database was used to determine the number of power supply faults (over 1,700 reports), and tokamak annual operations data supplied the number of shots, operating times, and power supply usage for the DIII-D operating campaigns between mid-1987 and 2004. Where possible, these power supply failure rates from DIII-D will be compared to similar work that has been performed for the Joint European Torus equipment. These independent data sets support validation of the fusion-specific failure rate values.

  11. Ac-dc converter firing error detection

    SciTech Connect

    Gould, O.L.

    1996-07-15

    Each of the twelve Booster Main Magnet Power Supply modules consist of two three-phase, full-wave rectifier bridges in series to provide a 560 VDC maximum output. The harmonic contents of the twelve-pulse ac-dc converter output are multiples of the 60 Hz ac power input, with a predominant 720 Hz signal greater than 14 dB in magnitude above the closest harmonic components at maximum output. The 720 Hz harmonic is typically greater than 20 dB below the 500 VDC output signal under normal operation. Extracting specific harmonics from the rectifier output signal of a 6, 12, or 24 pulse ac-dc converter allows the detection of SCR firing angle errors or complete misfires. A bandpass filter provides the input signal to a frequency-to-voltage converter. Comparing the output of the frequency-to-voltage converter to a reference voltage level provides an indication of the magnitude of the harmonics in the ac-dc converter output signal.

  12. Development of ATC for High Speed and High Density Commuter Line

    NASA Astrophysics Data System (ADS)

    Okutani, Tamio; Nakamura, Nobuyuki; Araki, Hisato; Irie, Shouji; Osa, Hiroki; Sano, Minoru; Ikeda, Keigo; Ozawa, Hiroyuki

    A new ATC (Automatic Train Control) system has been developed with solutions to realize short train headway by assured braking utilizing digital data transmission via rails; the digital data for the ATP (Automatic Train Protection) function; and to achieve EMC features for both AC and DC sections. The DC section is of the unprecedented DC traction power supply system utilizing IGBT PWM converter at all DC substations. Within the AC section, train traction force is controlled by PWM converter/inverters. The carrier frequencies of the digital data signals and chopping frequency of PWM traction power converters on-board are decided via spectral analysis of noise up to degraded mode cases of equipment. Developed system was equipped to the Tukuba Express Line, new commuter line of Tokyo metropolitan area, and opened since Aug. 2005.

  13. Reduced Toxicity Fuel Satellite Propulsion System Including Axial Thruster and ACS Thruster Combination

    NASA Technical Reports Server (NTRS)

    Schneider, Steven J. (Inventor)

    2001-01-01

    A reduced toxicity fuel satellite propulsion system including a reduced toxicity propellant supply for consumption in an axial class thruster and an ACS class thruster. The system includes suitable valves and conduits for supplying the reduced toxicity propellant to the ACS decomposing element of an ACS thruster. The ACS decomposing element is operative to decompose the reduced toxicity propellant into hot propulsive gases. In addition the system includes suitable valves and conduits for supplying the reduced toxicity propellant to an axial decomposing element of the axial thruster. The axial decomposing element is operative to decompose the reduced toxicity propellant into hot gases. The system further includes suitable valves and conduits for supplying a second propellant to a combustion chamber of the axial thruster, whereby the hot gases and the second propellant auto-ignite and begin the combustion process for producing thrust.

  14. Tevatron AC dipole system

    SciTech Connect

    Miyamoto, R.; Kopp, S.E.; Jansson, A.; Syphers, M.J.; /Fermilab

    2007-06-01

    The AC dipole is an oscillating dipole magnet which can induce large amplitude oscillations without the emittance growth and decoherence. These properties make it a good tool to measure optics of a hadron synchrotron. The vertical AC dipole for the Tevatron is powered by an inexpensive high power audio amplifier since its operating frequency is approximately 20 kHz. The magnet is incorporated into a parallel resonant system to maximize the current. The use of a vertical pinger magnet which has been installed in the Tevatron made the cost relatively inexpensive. Recently, the initial system was upgraded with a more powerful amplifier and oscillation amplitudes up to 2-3{sigma} were achieved with the 980 GeV proton beam. This paper discusses details of the Tevatron AC dipole system and also shows its test results.

  15. ac bidirectional motor controller

    NASA Technical Reports Server (NTRS)

    Schreiner, K.

    1988-01-01

    Test data are presented and the design of a high-efficiency motor/generator controller at NASA-Lewis for use with the Space Station power system testbed is described. The bidirectional motor driver is a 20 kHz to variable frequency three-phase ac converter that operates from the high-frequency ac bus being designed for the Space Station. A zero-voltage-switching pulse-density-modulation technique is used in the converter to shape the low-frequency output waveform.

  16. 78 FR 39345 - ACS Wireless, Inc.; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-01

    ... current assets including cash, accounts receivable, material, supplies, prepayment and other current assets (``Current Assets''), and (ii) $74.2 million of property and plant and equipment (``PP&E'').\\5\\ Applicant states that many of the assets categorized as Current Assets will remain with ACS Wireless...

  17. Ac-Induced Instability at the Xanthophyllic Locus of Tomato

    PubMed Central

    Peterson, P. W.; Yoder, J. I.

    1993-01-01

    To detect genomic instability caused by Ac elements in transgenic tomatoes, we used the incompletely dominant mutation Xanthophyllic-1 (Xa-1) as a whole plant marker gene. Xa-1 is located on chromosome 10 and in the heterozygote state causes leaves to be yellow. Transgenic Ac-containing tomato plants which differed in the location and number of their Ac elements were crossed to Xa-1 tester lines and F(1) progeny were scored for aberrant somatic sectoring. Of 800 test and control F(1) progeny screened, only four plants had aberrantly high levels of somatic sectors. Three of the plants had twin sectors consisting of green tissue adjacent to white tissue, and the other had twin sectors comprised of green tissue adjacent to tissue more yellow than the heterozygote background. Sectoring was inherited and the two sectoring phenotypes mapped to opposite homologs of chromosome 10; the green/yellow sectoring phenotype mapped in coupling to Xa-1 while the green/white sectoring phenotype mapped in repulsion. The two sectoring phenotypes cosegregated with different single, non-rearranged Acs, and loss of these Acs from the genome corresponded to the loss of sectoring. Sectoring was still observed after transposition of the Ac to a new site which indicated that sectoring was not limited to a single locus. In both sectored lines, meiotic recombination of the sectoring Ac to the opposite homolog caused the phenotype to switch between the green/yellow and the green/white phenotypes. Thus the two different sectoring phenotypes arose from the same Ac-induced mechanism; the phenotype depended on which chromosome 10 homolog the Ac was on. We believe that the twin sectors resulted from chromosome breakage mediated by a single intact, transposition-competent Ac element. PMID:8394266

  18. 60kV, 10Amp DC power supply multiple input control and monitoring provision for the operation of various high power RF generation systems

    NASA Astrophysics Data System (ADS)

    Parmar, Kirit M.; Srinivas, Y. S. S.; Kulkarni, S. V.; ICRH-RF Group

    2010-02-01

    A 60 kV, 10 A DC power supply is used for testing of high power RF and microwave tubes e.g. Klystron, Gyrotron. Two 500 kW, 3.7 GHz klystrons, and one 82.6 GHz Gyrotron are located in SST1 Hall where as 200 kW; 28 GHz Gyrotron is located in Aditya Hall. The same power supply is required to operate, control and monitor various systems at different locations with easy change over from one system to other as per experimental requirements. An off line, control change over system, is designed to accomplish the above requirements, with control panels installed at desired different locations. The input (0 to 11 kV) A.C. voltage to power supply is given from a motorized voltage variation system (VVS). The control panels provide indication of A.C. input voltage to power supply from 11 kV potential transformers of VVS. In addition, the control panel is provided with 11 kV circuit breaker status indication and control i.e. Emergency OFF switch. The control panels are designed and developed indigenously which are successfully installed and are in continuous use for the safe and easy operation of different high power rf systems from the same DC power supply. The paper presents the design of the controls, monitoring and indications. Safety aspects of the system are also highlighted.

  19. AC/RF Superconductivity

    SciTech Connect

    Ciovati, Gianluigi

    2015-02-01

    This contribution provides a brief introduction to AC/RF superconductivity, with an emphasis on application to accelerators. The topics covered include the surface impedance of normal conductors and superconductors, the residual resistance, the field dependence of the surface resistance, and the superheating field.

  20. AC solar cell

    SciTech Connect

    Schutten, H.P.; Benjamin, J.A.; Lade, R.W.

    1986-03-18

    An AC solar cell is described comprising: a pair of PN junction type solar cells connected in antiparallel between a pair of main terminals; and means for electrically directing light alternatingly without mechanical movement on the PN junctions to generate an alternating potential across the main terminals.

  1. AC 67 Launch Video

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Live footage of the Unmanned Atlas Centaur (AC) 67 launch is presented on March 26, 1987 at the WESH television station in Florida. Lightning is shown after 49 seconds into the flight. The vehicle is totally destroyed due to a cloud-to-ground lightning flash.

  2. Measurement of coupling resonance driving terms with the AC dipole

    SciTech Connect

    Miyamoto, R.

    2010-10-01

    Resonance driving terms for linear coupled betatron motion in a synchrotron ring can be determined from corresponding spectral lines of an excited coherent beam motion. An AC dipole is one of instruments to excite such a motion. When a coherent motion is excited with an AC dipole, measured Courant-Snyder parameters and betatron phase advance have apparent modulations, as if there is an additional quadrupole field at the location of the AC dipole. Hence, measurements of these parameters using the AC dipole require a proper interpretation of observed quantities. The situation is similar in measurements of resonance driving terms using the AC dipole. In this note, we derive an expression of coupled betatron motion excited with two AC dipoles in presence of skew quadrupole fields, discuss an impact of this quadrupole like effect of the AC dipole on a measurement of coupling resonance driving terms, and present an analytical method to determine the coupling resonance driving terms from quantities observed using the AC dipole.

  3. AC power systems handbook

    SciTech Connect

    Whitaker, J.

    1991-01-01

    Transient disturbances are what headaches are made of. Whatever you call them-spikes, surges, are power bumps-they can take your equipment down and leave you with a complicated and expensive repair job. Protection against transient disturbances is a science that demands attention to detail. This book explains how the power distribution system works, what can go wrong with it, and how to protect a facility against abnormalities. system grounding and shielding are covered in detail. Each major method of transient protection is analyzed and its relative merits discussed. The book provides a complete look at the critical elements of the ac power system. Provides a complete look at the ac power system from generation to consumption. Discusses the mechanisms that produce transient disturbances and how to protect against them. Presents diagrams to facilitate system design. Covers new areas, such as the extent of the transient disturbance problem, transient protection options, and stand-by power systems.

  4. Design of a -1 MV dc UHV power supply for ITER NBI

    NASA Astrophysics Data System (ADS)

    Watanabe, K.; Yamamoto, M.; Takemoto, J.; Yamashita, Y.; Dairaku, M.; Kashiwagi, M.; Taniguchi, M.; Tobari, H.; Umeda, N.; Sakamoto, K.; Inoue, T.

    2009-05-01

    Procurement of a dc -1 MV power supply system for the ITER neutral beam injector (NBI) is shared by Japan and the EU. The Japan Atomic Energy Agency as the Japan Domestic Agency (JADA) for ITER contributes to the procurement of dc -1 MV ultra-high voltage (UHV) components such as a dc -1 MV generator, a transmission line and a -1 MV insulating transformer for the ITER NBI power supply. The inverter frequency of 150 Hz in the -1 MV power supply and major circuit parameters have been proposed and adopted in the ITER NBI. The dc UHV insulation has been carefully designed since dc long pulse insulation is quite different from conventional ac insulation or dc short pulse systems. A multi-layer insulation structure of the transformer for a long pulse up to 3600 s has been designed with electric field simulation. Based on the simulation the overall dimensions of the dc UHV components have been finalized. A surge energy suppression system is also essential to protect the accelerator from electric breakdowns. The JADA contributes to provide an effective surge suppression system composed of core snubbers and resistors. Input energy into the accelerator from the power supply can be reduced to about 20 J, which satisfies the design criteria of 50 J in total in the case of breakdown at -1 MV.

  5. Technical Aspects of the Advanced Camera For Surveys Repair (ACS-R)

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen; Cheng, Edward S.; Sirianni, Marco

    2008-01-01

    The ACS Repair (ACS-R) team includes contributors from NASA's Goddard Space Flight Center, Ball Aerospace, and Teledyne Imaging Sensors; It determined that all of the capabilities of the ACS could be restored and created a concept for the ACS-R component of SN4. ACSR will restore the WFC of ACS by replacing the existing CCD Electronics Box (CEB) with the CEB-Replacement (CEB-R) and providing power from a new Low Voltage Power Supply Replacement (LVPS-8). The new LVPS-R will also attempt to restore the HRC function by providing power through the original power bus. In this presentation, we faeus on the concept and technical aspects of the ACS-R.

  6. The Hubble Legacy Archive ACS grism data

    NASA Astrophysics Data System (ADS)

    Kümmel, M.; Rosati, P.; Fosbury, R.; Haase, J.; Hook, R. N.; Kuntschner, H.; Lombardi, M.; Micol, A.; Nilsson, K. K.; Stoehr, F.; Walsh, J. R.

    2011-06-01

    A public release of slitless spectra, obtained with ACS/WFC and the G800L grism, is presented. Spectra were automatically extracted in a uniform way from 153 archival fields (or "associations") distributed across the two Galactic caps, covering all observations to 2008. The ACS G800L grism provides a wavelength range of 0.55-1.00 μm, with a dispersion of 40 Å/pixel and a resolution of ~80 Å for point-like sources. The ACS G800L images and matched direct images were reduced with an automatic pipeline that handles all steps from archive retrieval, alignment and astrometric calibration, direct image combination, catalogue generation, spectral extraction and collection of metadata. The large number of extracted spectra (73,581) demanded automatic methods for quality control and an automated classification algorithm was trained on the visual inspection of several thousand spectra. The final sample of quality controlled spectra includes 47 919 datasets (65% of the total number of extracted spectra) for 32 149 unique objects, with a median iAB-band magnitude of 23.7, reaching 26.5 AB for the faintest objects. Each released dataset contains science-ready 1D and 2D spectra, as well as multi-band image cutouts of corresponding sources and a useful preview page summarising the direct and slitless data, astrometric and photometric parameters. This release is part of the continuing effort to enhance the content of the Hubble Legacy Archive (HLA) with highly processed data products which significantly facilitate the scientific exploitation of the Hubble data. In order to characterize the slitless spectra, emission-line flux and equivalent width sensitivity of the ACS data were compared with public ground-based spectra in the GOODS-South field. An example list of emission line galaxies with two or more identified lines is also included, covering the redshift range 0.2 - 4.6. Almost all redshift determinations outside of the GOODS fields are new. The scope of science projects

  7. Steady-state analysis of a faulted three-phase four-wire system supplying induction motors with neutrals connected and other single-phase line-to-neutral loads

    NASA Technical Reports Server (NTRS)

    Wood, M. E.

    1980-01-01

    Four wire Wye connected ac power systems exhibit peculiar steady state fault characteristics when the fourth wire of three phase induction motors is connected. The loss of one phase of power source due to a series or shunt fault results in currents higher than anticipated on the remaining two phases. A theoretical approach to compute the fault currents and voltages is developed. A FORTRAN program is included in the appendix.

  8. Accelerator Production of 225Ac For Alpha-Immunotherapy

    NASA Astrophysics Data System (ADS)

    Weidner, J. W.; Nortier, F. M.; Bach, H. T.; John, K. D.; Couture, A.; Ullmann, J. L.; Fassbender, M. E.; Goff, G. S.; Taylor, W.; Valdez, F.; Wolfsberg, L. E.; Cisneros, M.; Dry, D.; Gallegos, M.; Gritzo, R.; Bitteker, L. J.; Wender, S.; Baty, R. S.

    2011-06-01

    225Ac has tremendous potential for the treatment of metastatic cancer due to the four alpha-particles emitted during its decay to stable 209Bi. Additionally, it is one of the few alpha-emitters being considered for clinical trials. The anticipated 225Ac demand for these trials is expected to far exceed the annual worldwide supply of approximately 1,000 mCi/yr. Consequently, the DOE Office of Science has funded investigations into accelerator-based production of 225Ac. Existing 232Th(p,x)225Ac cross section data indicate that up to 480 mCi/day of 225Ac could be created by bombarding a thick target of natural thorium with 100 MeV protons at the Los Alamos Isotope Production Facility. To verify these predictions, experiments are underway at the Los Alamos Neutron Science Center to measure the 232Th(p,x)225Ac production cross sections for protons in the energy range 40-200 MeV, and at 800 MeV. For 800 MeV protons, preliminary results indicate that the 225Ac production cross section is 12.4±0.6 mb and the 225Ra production cross section is 3.2±0.2 mb. Moreover, preliminary results suggest that the 227Ac production cross section is 16±1 mb. Experiments to measure these same cross sections at proton energies below 200 MeV are planned for the last half of calendar year 2010.

  9. Accelerator Production of {sup 225}Ac For Alpha-Immunotherapy

    SciTech Connect

    Weidner, J. W.; Nortier, F. M.; Bach, H. T.; John, K. D.; Couture, A.; Ullmann, J. L.; Fassbender, M. E.; Goff, G. S.; Taylor, W.; Valdez, F.; Wolfsberg, L. E.; Cisneros, M.; Dry, D.; Gallegos, M.; Gritzo, R.; Bitteker, L. J.; Wender, S.; Baty, R. S.

    2011-06-01

    {sup 225}Ac has tremendous potential for the treatment of metastatic cancer due to the four alpha-particles emitted during its decay to stable {sup 209}Bi. Additionally, it is one of the few alpha-emitters being considered for clinical trials. The anticipated {sup 225}Ac demand for these trials is expected to far exceed the annual worldwide supply of approximately 1,000 mCi/yr. Consequently, the DOE Office of Science has funded investigations into accelerator-based production of {sup 225}Ac. Existing {sup 232}Th(p,x){sup 225}Ac cross section data indicate that up to 480 mCi/day of {sup 225}Ac could be created by bombarding a thick target of natural thorium with 100 MeV protons at the Los Alamos Isotope Production Facility. To verify these predictions, experiments are underway at the Los Alamos Neutron Science Center to measure the {sup 232}Th(p,x){sup 225}Ac production cross sections for protons in the energy range 40-200 MeV, and at 800 MeV. For 800 MeV protons, preliminary results indicate that the {sup 225}Ac production cross section is 12.4{+-}0.6 mb and the {sup 225}Ra production cross section is 3.2{+-}0.2 mb. Moreover, preliminary results suggest that the {sup 227}Ac production cross section is 16{+-}1 mb. Experiments to measure these same cross sections at proton energies below 200 MeV are planned for the last half of calendar year 2010.

  10. Identification of /sup 233/Ac

    SciTech Connect

    Chu, Y.Y.; Zhou, M.L.

    1983-09-01

    We report in this paper identification of the new isotope /sup 233/Ac. Uranium targets were irradiated with 28 GeV protons; after rapid retrieval of the target and separation of actinium from thorium, /sup 233/Ac was allowed to decay into the known /sup 233/Th daughter. Exhaustive chemical purification was employed to permit the identification of /sup 233/Th via its characteristic ..gamma.. radiations. The half-life derived for /sup 233/Ac from several experiments is 2.3 +- 0.3 min. The production cross section for /sup 233/Ac is 100 ..mu..b.

  11. Health supply chain management.

    PubMed

    Zimmerman, Rolf; Gallagher, Pat

    2010-01-01

    This chapter gives an educational overview of: * The actual application of supply chain practice and disciplines required for service delivery improvement within the current health environment. * A rationale for the application of Supply Chain Management (SCM) approaches to the Health sector. * The tools and methods available for supply chain analysis and benchmarking. * Key supply chain success factors. PMID:20407173

  12. PUREX (SAMCONS) uninterruptible power supply (UPS) acceptance test procedure

    SciTech Connect

    Blackaby, W.B.

    1997-09-01

    This Acceptance Test Procedure for the PUREX Surveillance and Monitoring and Control System (SAMCONS) Uninterruptible Power Supply (UPS) provides for testing and verifying the proper operation of the control panel alarms and trouble functions, the 6roper functioning of the AC inverter, ability of the battery supply to maintain the SAMCONS load for a minimum of two hours , and proper interaction with the SAMCONS Video graphic displays for alarm displays.

  13. Inductive energy harvesting from variable frequency and amplitude aircraft power lines

    NASA Astrophysics Data System (ADS)

    Toh, T. T.; Wright, S. W.; Kiziroglou, M. E.; Mueller, J.; Sessinghaus, M.; Yeatman, E. M.; Mitcheson, P. D.

    2014-11-01

    This paper presents a non-contact method of harvesting energy from an aircraft power line that has an AC current of variable amplitude and a frequency range of 360-800 Hz. The current and frequency characteristics of the aircraft power line are dependent on the rotation speed of the electrical generators and will therefore change during a flight. The harvester consists of an inductive coil with a ferrite core, which is interfaced to a rectifier, step-down regulator and supercapacitor. A prototype system was constructed to demonstrate reliable output voltage regulation across a supercapacitor that will supply a peak power of 100 mW under duty cycled load conditions. The system could fully charge a 40 mF supercapacitor to 3.3 V in 78 s from a power line current of 1.5 Arms at 650 Hz.

  14. Ac loss calorimeter for three-phase cable

    SciTech Connect

    Daney, D.E.; Boenig, H.J.; Maley, M.P.; McMurry, D.E.; DeBlanc, B.G.

    1996-10-01

    A calorimeter for measuring ac losses in meter-long lengths of HTS superconducting power transmission line cables is described. The calorimeter, which is based on a temperature difference technique, has a precision of 1 mW and measures single, two-phase (coupling), and three-phase losses. The measurements show significant coupling losses between phases.

  15. Power factor control system for AC induction motors

    NASA Technical Reports Server (NTRS)

    Nola, F. J. (Inventor)

    1977-01-01

    A power factor control system for use with ac induction motors was designed which samples lines voltage and current through the motor and decreases power input to the motor proportional to the detected phase displacement between current and voltage. This system provides, less power to the motor, as it is less loaded.

  16. Digital ac monitor

    DOEpatents

    Hart, George W.; Kern, Jr., Edward C.

    1987-06-09

    An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer.

  17. Thermionic triode generates ac power

    NASA Technical Reports Server (NTRS)

    Kniazzeh, A. G. F.; Scharz, F. C.

    1970-01-01

    Electrostatic grid controls conduction cycle of thermionic diode to convert low dc output voltages to high ac power without undesirable power loss. An ac voltage applied to the grid of this new thermionic triode enables it to convert heat directly into high voltage electrical power.

  18. Automated ac galvanomagnetic measurement system

    NASA Technical Reports Server (NTRS)

    Szofran, F. R.; Espy, P. N.

    1985-01-01

    An automated, ac galvanomagnetic measurement system is described. Hall or van der Pauw measurements in the temperature range 10-300 K can be made at a preselected magnetic field without operator attendance. Procedures to validate sample installation and correct operation of other system functions, such as magnetic field and thermometry, are included. Advantages of ac measurements are discussed.

  19. Assessing Fungal Population in Soil Planted with Cry1Ac and CPTI Transgenic Cotton and Its Conventional Parental Line Using 18S and ITS rDNA Sequences over Four Seasons.

    PubMed

    Qi, Xiemin; Liu, Biao; Song, Qinxin; Zou, Bingjie; Bu, Ying; Wu, Haiping; Ding, Li; Zhou, Guohua

    2016-01-01

    Long-term growth of genetically modified plants (GMPs) has raised concerns regarding their ecological effects. Here, FLX-pyrosequencing of region I (18S) and region II (ITS1, 5.8S, and ITS2) rDNA was used to characterize fungal communities in soil samples after 10-year monoculture of one representative transgenic cotton line (TC-10) and 15-year plantation of various transgenic cotton cultivars (TC-15mix) over four seasons. Soil fungal communities in the rhizosphere of non-transgenic control (CC) were also compared. No notable differences were observed in soil fertility variables among CC, TC-10, and TC-15mix. Within seasons, the different estimations were statistically indistinguishable. There were 411 and 2 067 fungal operational taxonomic units in the two regions, respectively. More than 75% of fungal taxa were stable in both CC and TC except for individual taxa with significantly different abundance between TC and CC. Statistical analysis revealed no significant differences between CC and TC-10, while discrimination of separating TC-15mix from CC and TC-10 with 37.86% explained variance in PCoA and a significant difference of Shannon indexes between TC-10 and TC-15mix were observed in region II. As TC-15mix planted with a mixture of transgenic cottons (Zhongmian-29, 30, and 33B) for over 5 years, different genetic modifications may introduce variations in fungal diversity. Further clarification is necessary by detecting the fungal dynamic changes in sites planted in monoculture of various transgenic cottons. Overall, we conclude that monoculture of one representative transgenic cotton cultivar may have no effect on fungal diversity compared with conventional cotton. Furthermore, the choice of amplified region and methodology has potential to affect the outcome of the comparison between GM-crop and its parental line. PMID:27462344

  20. Assessing Fungal Population in Soil Planted with Cry1Ac and CPTI Transgenic Cotton and Its Conventional Parental Line Using 18S and ITS rDNA Sequences over Four Seasons

    PubMed Central

    Qi, Xiemin; Liu, Biao; Song, Qinxin; Zou, Bingjie; Bu, Ying; Wu, Haiping; Ding, Li; Zhou, Guohua

    2016-01-01

    Long-term growth of genetically modified plants (GMPs) has raised concerns regarding their ecological effects. Here, FLX-pyrosequencing of region I (18S) and region II (ITS1, 5.8S, and ITS2) rDNA was used to characterize fungal communities in soil samples after 10-year monoculture of one representative transgenic cotton line (TC-10) and 15-year plantation of various transgenic cotton cultivars (TC-15mix) over four seasons. Soil fungal communities in the rhizosphere of non-transgenic control (CC) were also compared. No notable differences were observed in soil fertility variables among CC, TC-10, and TC-15mix. Within seasons, the different estimations were statistically indistinguishable. There were 411 and 2 067 fungal operational taxonomic units in the two regions, respectively. More than 75% of fungal taxa were stable in both CC and TC except for individual taxa with significantly different abundance between TC and CC. Statistical analysis revealed no significant differences between CC and TC-10, while discrimination of separating TC-15mix from CC and TC-10 with 37.86% explained variance in PCoA and a significant difference of Shannon indexes between TC-10 and TC-15mix were observed in region II. As TC-15mix planted with a mixture of transgenic cottons (Zhongmian-29, 30, and 33B) for over 5 years, different genetic modifications may introduce variations in fungal diversity. Further clarification is necessary by detecting the fungal dynamic changes in sites planted in monoculture of various transgenic cottons. Overall, we conclude that monoculture of one representative transgenic cotton cultivar may have no effect on fungal diversity compared with conventional cotton. Furthermore, the choice of amplified region and methodology has potential to affect the outcome of the comparison between GM-crop and its parental line. PMID:27462344

  1. Optimization of Resonant Power Supply Circuit

    SciTech Connect

    Karady, G.G.; Thiessen, H.A.

    1989-01-01

    A Resonant Power Supply has been proposed to power Rapid Cycling Accelerator magnets. The Resonant Power Supply circuits were studied extensively, but were not optimized. Most designs assume equal choke and magnet inductance, however, the variation of inductance affects both performance and cost of the system. This paper optimizes the Resonant Power Supply Circuit by selecting the most feasible choke inductance. For this optimization, a computer model and an approximate design method were developed. The effect of choke inductance on the components rating and cost was determined. It was found that the increase of choke inductance reduces the maximum and increases the minimum choke current, which leads to a significant increase of system losses. The maximum voltage is independent of the choke inductance. The described change of choke current reduces the current of the Bypass Thyristor Switch and the Capacitor Bank Switch, which results in cost reduction. The increase of choke inductance reduces the size of capacitor banks. The loss increase requires larger Make-up Power Supply and ac supply systems. It also increases the operation costs. The system cost function has a minimum, when the choke inductance is about 1.5--2 times larger than the magnet one. The application of the result will lead to a more economical and efficient Resonant Power Supply. 2 refs., 8 figs., 1 tab.

  2. REPEATED SEQUENCES INCLUDING RS1100 FROM PSEUDOMONAS CEPACIA AC100 FUNCTION AS IS ELEMENTS

    EPA Science Inventory

    Several lines of evidence were obtained that the previously identified, repeated sequence RS1100 of Pseudomonas cepacia strain AC1100 undergoes transposition events. NA sequences flanking the chlorohydroxy hydroquinone (CHQ) degradative genes of this organism were examined from s...

  3. Bimode uninterruptible power supply compatibility in renewable hybrid energy systems

    SciTech Connect

    Bower, W. ); O'Sullivan, G. )

    1990-08-01

    Inverters installed in renewable hybrid energy systems are typically used in a stand-alone mode to supply ac power to loads from battery storage when the engine-generator is not being used. Similarities in topology and in the performance requirements of the standby uninterruptible power supply (UPS) system and the hybrid system suggest the UPS could be used in hybrid energy systems. Another alternative to inverters with add-on charging circuits or standby UPS hardware is the Bimode UPS. The bimode UPS uses common circuitry and power components for dc to ac inversion and battery charging. It also provides an automatic and nearly instantaneous ac power transfer function when the engine-generator is started or stopped. The measured operating and transfer characteristics of a bimode UPS in a utility system and in a hybrid system are presented. The applicability of the bimode UPS to hybrid systems and its compatibility in a PV/engine-generator hybrid system are given.

  4. Operation Method for AC Motor Control during Power Interruption in Direct AC/AC Converter System

    NASA Astrophysics Data System (ADS)

    Shizu, Keiichiro; Azuma, Satoshi

    Direct AC/AC converters have been studied due to their potential use in power converters with no DC-link capacitor, which can contribute to the miniaturization of power converters. However, the absence of a DC-link capacitor makes it difficult to control the AC motor during power interruption. First, this paper proposes a system that realizes AC motor control during power interruption by utilizing a clamp capacitor. In general, direct AC/AC converters have a clamp circuit consisting of a rectifier diode(s) and a clamp capacitor in order to avoid over-voltages. In the proposed system, there is an additional semiconductor switch reverse-parallel to the rectifier diode(s), and the clamp capacitor voltage can be utilized for AC motor control by turning on the additional switch. Second, this paper discusses an operation method for AC motor control and clamp capacitor voltage control during power interruption. In the proposed method “DC-link voltage control”, the kinetic energy in the AC motor is transformed into electrical energy and stored in the clamp capacitor; the clamp capacitor is therefore charged and the capacitor voltage is controlled to remain constant at an instruction value. Third, this paper discusses a switching operation during power interruption. A dead-time is introduced between the operation of turning off all switches on the rectifier side and the operation of turning on the additional switch, which prevents the occurrence of a short circuit between the interrupted power source and the clamp capacitor. Finally, experimental results are presented. During power interruptions, an output current was continuously obtained and the clamp capacitor voltage was maintained to be equal to the instruction value of the capacitor voltage. These results indicate that both AC motor control and capacitor voltage control were successfully achieved by using the proposed system.

  5. AC photovoltaic module magnetic fields

    SciTech Connect

    Jennings, C.; Chang, G.J.; Reyes, A.B.; Whitaker, C.M.

    1997-12-31

    Implementation of alternating current (AC) photovoltaic (PV) modules, particularly for distributed applications such as PV rooftops and facades, may be slowed by public concern about electric and magnetic fields (EMF). This paper documents magnetic field measurements on an AC PV module, complementing EMF research on direct-current PV modules conducted by PG and E in 1993. Although not comprehensive, the PV EMF data indicate that 60 Hz magnetic fields (the EMF type of greatest public concern) from PV modules are comparable to, or significantly less than, those from household appliances. Given the present EMF research knowledge, AC PV module EMF may not merit considerable concern.

  6. Feedstock Supply System Logistics

    SciTech Connect

    2006-06-01

    Feedstock supply is a significant cost component in the production of biobased fuels, products, and power. The uncertainty of the biomass feedstock supply chain and associated risks are major barriers to procuring capital funding for start-up biorefineries.

  7. Development of an AC Phase Controlled Testing Apparatus with an Impulse Voltage

    NASA Astrophysics Data System (ADS)

    Kando, Masaaki; Matsuo, Takashi

    Overvoltages as lightning surges and/or switching surges will affect power apparatuses and electric appliances, which make them of deterioration. However, recent AC testing apparatuses haven't been functions generating an impulse voltage. Moreover, the apparatuses with controlling an impulse voltage haven't been utilized except the low voltage function generator. Therefore, an AC phase controlled testing apparatus with an impulse voltage (0.8/6μs) has been developed in order to elucidate mechanism of the degradation in insulating materials with a AC power supply simulating the overvoltages.

  8. Ac traction gets on track

    SciTech Connect

    O`Connor, L.

    1995-09-01

    This article describes inverter-based ac traction systems which give freight locomotives greater adhesion, pulling power, and braking capacity. In the 1940s, dc traction replaced the steam engine as a source of train propulsion, and it has ruled the freight transportation industry ever since. But now, high-performance ac-traction systems, with their unprecedented levels of pulling power and adhesion, are becoming increasingly common on America`s freight railroads. In thousands of miles of demonstration tests, today`s ac-traction systems have outperformed traditional dc-motor driven systems. Major railroad companies are convinced enough of the benefits of ac traction to have integrated it into their freight locomotives.

  9. Power Supply Systems for Rapid Cycling Synchrotron

    NASA Astrophysics Data System (ADS)

    Watanabe, Yasuhiro; Adachi, Toshikazu; Someya, Hirohiko; Koseki, Shoichiro; Ogawa, Shinichi

    JAEA and KEK are jointly constructing a high intensity proton accelerator project J-PARC. Its main accelerator is 3GeV rapid cycling synchrotron (RCS). Two types of resonant excitation systems, parallel and cascade, are introduced to excite DC biased 25Hz AC currents through its main magnets. The parallel excitation is adopted for dipole magnets power supply system, and the cascade excitations are adopted for seven family quadrupole magnets systems. In this paper, two systems are investigated and analyzed, and it is explained why different types are adopted to each system. Authors believe that such hybrid exciting systems are most suitable for high power RCS.

  10. AC Zeeman potentials for atom chip-based ultracold atoms

    NASA Astrophysics Data System (ADS)

    Fancher, Charles; Pyle, Andrew; Ziltz, Austin; Aubin, Seth

    2015-05-01

    We present experimental and theoretical progress on using the AC Zeeman force produced by microwave magnetic near-fields from an atom chip to manipulate and eventually trap ultracold atoms. These AC Zeeman potentials are inherently spin-dependent and can be used to apply qualitatively different potentials to different spin states simultaneously. Furthermore, AC Zeeman traps are compatible with the large DC magnetic fields necessary for accessing Feshbach resonances. Applications include spin-dependent trapped atom interferometry and experiments in 1D many-body physics. Initial experiments and results are geared towards observing the bipolar detuning-dependent nature of the AC Zeeman force at 6.8 GHz with ultracold 87Rb atoms trapped in the vicinity of an atom chip. Experimental work is also underway towards working with potassium isotopes at frequencies of 1 GHz and below. Theoretical work is focused on atom chip designs for AC Zeeman traps produced by magnetic near-fields, while also incorporating the effect of the related electric near-fields. Electromagnetic simulations of atom chip circuits are used for mapping microwave propagation in on-chip transmission line structures, accounting for the skin effect, and guiding impedance matching.

  11. Switching power supply filter

    NASA Technical Reports Server (NTRS)

    Kumar, Prithvi R. (Inventor); Abare, Wayne (Inventor)

    1989-01-01

    A filter for a switching power supply. The filter includes a common mode inductor with coil configurations allowing differential mode current from a dc source to pass through but attenuating common mode noise from the power supply so that the noise does not reach the dc source. The invention also includes the use of feed through capacitors at the switching power supply input terminals to provide further high-frequency noise attenuation.

  12. [Allelopathy and resources competition of rice under different nitrogen supplies].

    PubMed

    Xiong, Jun; Lin, Wenxiong; Zhou, Junjian; Wu, Minhong; Chen, Xiangxu; He, Huaqin; Guo, Yuchun; Liang, Yiyuan

    2005-05-01

    In order to explore the bio-interference of allelopathic rice with barnyardgrass under different nitrogen supplies, a new bioassay method, i.e., allelopathy-competition separation based (ACS) approach was recommended in this study. The results indicated that ACS could be successfully used to distinguish the rice allelopathy from its resources competition in rice-weed co-culture system, and to evaluate its response characteristics under different N supplies. The test rice accession PI312777 had a higher ability in interfering target weed barnyardgrass (BYD), represented by its stable and higher ability in resources competition, as well as its increasing allelopathic potential in suppressing companion weed BYD when the N supply decreased in the co-cultured system. The reverse was true in the case of rice accession Lemont, which had a lower allelopathic potential under all N supply levels, and a lower ability in resources competition under normal or rich N supply. But, Lemont had an obviously increased ability in resources competition under lower N supply, which was considered as the result of econiche competition in rice-weed system. PMID:16110664

  13. Ambulatory purchasing: harnessing supply costs.

    PubMed

    Jager, P A

    1997-04-01

    The healthcare system remains in a dynamic state of flux. We have all heard the story: the changing healthcare market brings reduced reimbursement for services, increased competition, and steadily increasing supply, maintenance, and equipment costs. Ambulatory surgery centers (ASCs) must keep in sync with this change or fail to survive the current market forces. However, because they represent a small contract to various vendors, many ASCs pay premium prices for inventory while receiving less from Managed Care Plans (MCPs) and Health Maintenance Organizations (HMOs). This dilemma makes control of supply costs a top priority for ASCs. In reality, purchasing is becoming more strategically connected to the ASC balance sheet than ever before. Apart from personnel costs, supply and pharmaceutical purchasing represents the greatest expense category on our financial statement. Harnessing these costs directly relates to bottom line profitability. In addition, while performing cost savings magic, ASCs must maintain patient and surgeon satisfaction with the superior outcomes and state-of-the-art technology their reputations are based upon. Sound impossible? This article details how Surgery Center Plus, Inc. (SCP) implemented a cost containment project. PMID:10167012

  14. ac power control in the Core Flow Test Loop

    SciTech Connect

    McDonald, D.W.

    1980-01-01

    This work represents a status report on a development effort to design an ac power controller for the Core Flow Test Loop. The Core Flow Test Loop will be an engineering test facility which will simulate the thermal environment of a gas-cooled fast-breeder reactor. The problems and limitations of using sinusoidal ac power to simulate the power generated within a nuclear reactor are addressed. The transformer-thyristor configuration chosen for the Core Flow Test Loop power supply is presented. The initial considerations, design, and analysis of a closed-loop controller prototype are detailed. The design is then analyzed for improved performance possibilities and failure modes are investigated at length. A summary of the work completed to date and a proposed outline for continued development completes the report.

  15. Tomato ACS4 is necessary for timely start of and progression through the climacteric phase of fruit ripening

    PubMed Central

    Hoogstrate, Suzanne W.; van Bussel, Lambertus J. A.; Cristescu, Simona M.; Cator, Eric; Mariani, Celestina; Vriezen, Wim H.; Rieu, Ivo

    2014-01-01

    Climacteric fruit ripening, as it occurs in many fruit crops, depends on a rapid, autocatalytic increase in ethylene production. This agriculturally important process has been studied extensively, with tomato simultaneously acting both as a model species and target crop for modification. In tomato, the ethylene biosynthetic genes ACC SYNTHASE2 (ACS2) and ACS4 are highly expressed during fruit ripening, with a combined loss of both ACS2 and ACS4 activity preventing generation of the ethylene burst necessary for fruit ripening. However, the individual roles and importance of ACS2 and ACS4 have not been determined. In this study, we examined specifically the role of ACS4 by comparing the phenotype of an acs4 mutant firstly with that of the wild-type, and secondly with two novel ripening-inhibitor (rin) mutants. Ethylene production during ripening was significantly reduced in both acs4-1, and rin lines, with rin genotypes showing the weaker ethylene burst. Also i) the time between anthesis and the start of fruit ripening and ii) the time required to progress through ripening were significantly longer in acs4-1 than in the wild type, but shorter than in the strongest rin mutant. The delay in ripening was reflected in the lower expression of ripening-related transcripts during the mature green and light red ripening stages. Furthermore, expression of ACS2 and ACS4 was strongly dependent on a functional RIN gene, while ACS2 expression was largely independent of ACS4. Altogether, we show that ACS4 is necessary for normal progression of tomato fruit ripening and that mutation of this gene may provide a useful means for altering ripening traits. PMID:25278945

  16. MUC5AC interactions with integrin β4 enhances the migration of lung cancer cells through FAK signaling.

    PubMed

    Lakshmanan, I; Rachagani, S; Hauke, R; Krishn, S R; Paknikar, S; Seshacharyulu, P; Karmakar, S; Nimmakayala, R K; Kaushik, G; Johansson, S L; Carey, G B; Ponnusamy, M P; Kaur, S; Batra, S K; Ganti, A K

    2016-08-01

    MUC5AC is a secretory mucin aberrantly expressed in various cancers. In lung cancer, MUC5AC is overexpressed in both primary and metastatic lesions; however, its functional role is not well understood. The present study was aimed at evaluating mechanistic role of MUC5AC on metastasis of lung cancer cells. Clinically, the overexpression of MUC5AC was observed in lung cancer patient tissues and was associated with poor survival. In addition, the overexpression of Muc5ac was also observed in genetically engineered mouse lung adenocarcinoma tissues (Kras(G12D); Trp53(R172H/+); AdCre) in comparison with normal lung tissues. Our functional studies showed that MUC5AC knockdown resulted in significantly decreased migration in two lung cancer cell lines (A549 and H1437) as compared with scramble cells. Expression of integrins (α5, β1, β3, β4 and β5) was decreased in MUC5AC knockdown cells. As both integrins and MUC5AC have a von Willebrand factor domain, we assessed for possible interaction of MUC5AC and integrins in lung cancer cells. MUC5AC strongly interacted only with integrin β4. The co-localization of MUC5AC and integrin β4 was observed both in A549 lung cancer cells as well as genetically engineered mouse adenocarcinoma tissues. Activated integrins recruit focal adhesion kinase (FAK) that mediates metastatic downstream signaling pathways. Phosphorylation of FAK (Y397) was decreased in MUC5AC knockdown cells. MUC5AC/integrin β4/FAK-mediated lung cancer cell migration was confirmed through experiments utilizing a phosphorylation (Y397)-specific FAK inhibitor. In conclusion, overexpression of MUC5AC is a poor prognostic marker in lung cancer. MUC5AC interacts with integrin β4 that mediates phosphorylation of FAK at Y397 leading to lung cancer cell migration. PMID:26751774

  17. Spatial Data Supply Chains

    NASA Astrophysics Data System (ADS)

    Varadharajulu, P.; Azeem Saqiq, M.; Yu, F.; McMeekin, D. A.; West, G.; Arnold, L.; Moncrieff, S.

    2015-06-01

    This paper describes current research into the supply of spatial data to the end user in as close to real time as possible via the World Wide Web. The Spatial Data Infrastructure paradigm has been discussed since the early 1990s. The concept has evolved significantly since then but has almost always examined data from the perspective of the supplier. It has been a supplier driven focus rather than a user driven focus. The current research being conducted is making a paradigm shift and looking at the supply of spatial data as a supply chain, similar to a manufacturing supply chain in which users play a significant part. A comprehensive consultation process took place within Australia and New Zealand incorporating a large number of stakeholders. Three research projects that have arisen from this consultation process are examining Spatial Data Supply Chains within Australia and New Zealand and are discussed within this paper.

  18. Power supply conditioning circuit

    NASA Technical Reports Server (NTRS)

    Primas, L. E.; Loveland, R.

    1987-01-01

    A power supply conditioning circuit that can reduce Periodic and Random Deviations (PARD) on the output voltages of dc power supplies to -150 dBV from dc to several KHz with no measurable periodic deviations is described. The PARD for a typical commercial low noise power supply is -74 dBV for frequencies above 20 Hz and is often much worse at frequencies below 20 Hz. The power supply conditioning circuit described here relies on the large differences in the dynamic impedances of a constant current diode and a zener diode to establish a dc voltage with low PARD. Power supplies with low PARD are especially important in circuitry involving ultrastable frequencies for the Deep Space Network.

  19. Alternative Ac/Ds transposition induces major chromosomal rearrangements in maize.

    PubMed

    Zhang, Jianbo; Yu, Chuanhe; Pulletikurti, Vinay; Lamb, Jonathan; Danilova, Tatiana; Weber, David F; Birchler, James; Peterson, Thomas

    2009-03-15

    Barbara McClintock reported that the Ac/Ds transposable element system can generate major chromosomal rearrangements (MCRs), but the underlying mechanism has not been determined. Here, we identified a series of chromosome rearrangements derived from maize lines containing pairs of closely linked Ac transposable element termini. Molecular and cytogenetic analyses showed that the MCRs in these lines comprised 17 reciprocal translocations and two large inversions. The breakpoints of all 19 MCRs are delineated by Ac termini and characteristic 8-base-pair target site duplications, indicating that the MCRs were generated by precise transposition reactions involving the Ac termini of two closely linked elements. This alternative transposition mechanism may have contributed to chromosome evolution and may also occur during V(D)J recombination resulting in oncogenic translocations. PMID:19299561

  20. The ac53, ac78, ac101, and ac103 Genes Are Newly Discovered Core Genes in the Family Baculoviridae

    PubMed Central

    Garavaglia, Matías Javier; Miele, Solange Ana Belén; Iserte, Javier Alonso; Belaich, Mariano Nicolás

    2012-01-01

    The family Baculoviridae is a large group of insect viruses containing circular double-stranded DNA genomes of 80 to 180 kbp, which have broad biotechnological applications. A key feature to understand and manipulate them is the recognition of orthology. However, the differences in gene contents and evolutionary distances among the known members of this family make it difficult to assign sequence orthology. In this study, the genome sequences of 58 baculoviruses were analyzed, with the aim to detect previously undescribed core genes because of their remote homology. A routine based on Multi PSI-Blast/tBlastN and Multi HaMStR allowed us to detect 31 of 33 accepted core genes and 4 orthologous sequences in the Baculoviridae which were not described previously. Our results show that the ac53, ac78, ac101 (p40), and ac103 (p48) genes have orthologs in all genomes and should be considered core genes. Accordingly, there are 37 orthologous genes in the family Baculoviridae. PMID:22933288

  1. Simple Equipment for Imaging AC.

    ERIC Educational Resources Information Center

    Kamata, Masahiro; Anayama, Takayuki

    2003-01-01

    Presents an effective way to demonstrate the difference between direct current and alternating current using red and green LEDs. Describes how to make a tool that shows how an AC voltage changes with time using the afterimage effect of the LEDs. (Author/NB)

  2. Semiconductor ac static power switch

    NASA Technical Reports Server (NTRS)

    Vrancik, J.

    1968-01-01

    Semiconductor ac static power switch has long life and high reliability, contains no moving parts, and operates satisfactorily in severe environments, including high vibration and shock conditions. Due to their resistance to shock and vibration, static switches are used where accidental switching caused by mechanical vibration or shock cannot be tolerated.

  3. Energy saving in ac generators

    NASA Technical Reports Server (NTRS)

    Nola, F. J.

    1980-01-01

    Circuit cuts no-load losses, without sacrificing full-load power. Phase-contro circuit includes gate-controlled semiconductor switch that cuts off applied voltage for most of ac cycle if generator idling. Switch "on" time increases when generator is in operation.

  4. Automating power supply checkout

    SciTech Connect

    Laster, J.; Bruno, D.; D'Ottavio, T.; Drozd, J.; Marr, G.; Mi, C.

    2011-03-28

    Power Supply checkout is a necessary, pre-beam, time-critical function. At odds are the desire to decrease the amount of time to perform the checkout while at the same time maximizing the number and types of checks that can be performed and analyzing the results quickly (in case any problems exist that must be addressed). Controls and Power Supply Group personnel have worked together to develop tools to accomplish these goals. Power Supply checkouts are now accomplished in a time-frame of hours rather than days, reducing the number of person-hours needed to accomplish the checkout and making the system available more quickly for beam development. The goal of the Collider-Accelerator Department (CAD) at Brookhaven National Laboratory is to provide experimenters with collisions of heavy-ions and polarized protons. The Relativistic Heavy-Ion Collider (RHIC) magnets are controlled by 100's of varying types of power supplies. There is a concentrated effort to perform routine maintenance on the supplies during shutdown periods. There is an effort at RHIC to streamline the time needed for system checkout in order to quickly arrive at a period of beam operations for RHIC. This time-critical period is when the checkout of the power supplies is performed as the RHIC ring becomes cold and the supplies are connected to their physical magnets. The checkout process is used to identify problems in voltage and current regulation by examining data signals related to each for problems in settling and regulation (ripple).

  5. An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.

    SciTech Connect

    Litzenberger, Wayne; Lava, Val

    1994-08-01

    References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

  6. Fast recovery, high voltage silicon diodes for AC motor controllers

    NASA Technical Reports Server (NTRS)

    Balodis, V.; Berman, A. H.; Gaugh, C.

    1982-01-01

    The fabrication and characterization of a high voltage, high current, fast recovery silicon diode for use in AC motor controllers, originally developed for NASA for use in avionics power supplies, is presented. The diode utilizes a positive bevel PIN mesa structure with glass passivation and has the following characteristics: peak inverse voltage - 1200 volts, forward voltage at 50 amperes - 1.5 volts, reverse recovery time of 200 nanoseconds. Characterization data for the diode, included in a table, show agreement with design concepts developed for power diodes. Circuit diagrams of the diode are also given.

  7. Tokamak Physics Experiment (TPX) power supply design and development

    SciTech Connect

    Neumeyer, C.; Bronner, G.; Lu, E.; Ramakrishnan, S.

    1995-04-01

    The Tokamak Physics Experiment (TPX) is an advanced tokamak project aimed at the production of quasi-steady state plasmas with advanced shape, heating, and particle control. TPX is to be built at the Princeton Plasma Physics Laboratory (PPPL) using many of the facilities from the Tokamak Fusion Test Reactor (TFTR). TPX will be the first tokamak to utilize superconducting (SC) magnets in both the toroidal field (TF) and poloidal field (PF) systems. This new feature requires a departure from the traditional tokamak power supply schemes. This paper describes the plan for the adaptation of the PPPL/FTR power system facilities to supply TPX. Five major areas are addressed, namely the AC power system, the TF, PF and Fast Plasma Position Control (FPPC) power supplies, and quench protection for the TF and PF systems. Special emphasis is placed on the development of new power supply and protection schemes.

  8. Lifting BLS Power Supplies

    SciTech Connect

    Sarychev, Michael

    2007-08-01

    This note describes BLS power supplies lifting techniques and provides stress calculations for lifting plate and handles bolts. BLS power supply weight is about 120 Lbs, with the center of gravity shifted toward the right front side. A lifting plate is used to attach a power supply to a crane or a hoist. Stress calculations show that safety factors for lifting plate are 12.9 (vs. 5 required) for ultimate stress and 5.7 (vs. 3 required) for yield stress. Safety factor for shackle bolt thread shear load is 37, and safety factor for bolts that attach handles is 12.8.

  9. ISTTOK upgrade towards AC and remote operation

    NASA Astrophysics Data System (ADS)

    Fernandes, H.; Silva, C.; Carvalho, B.; Sousa, J.; Valcárcel, D.; Neto, A.; Fortunato, J.; Carvalho, I.; Varandas, C. A. F.

    2006-12-01

    ISTTOK has performed one of the earliest experiments of AC tokamak operation showing that long discharges could be produced merely with inductive current drive. However, due to the design of the machine, the data acquisition system and the power supplies, a limit of 250 ms (six times the nominal forward shot duration) is currently imposed. In this paper the relevant constrains to attain current operation up to the limit of the stable toroidal magnetic field (3s) are discussed and the work being carried out to achieve this goal is presented. The conditions that shall be accomplished are: (i) removing the power deposited on the limiters; (ii) density control through gas puffing and monitoring the recycling from the walls; (iii) assessment of the free magnetic flux available on the iron core (Wmax=0.2 Vs); (iv) reformulation of the data acquisition system towards an event driven philosophy maintaining the actual distributed architecture but allowing a real-time control; (v) active control of the equilibrium magnetic fields implementing a digital plasma position estimator and actuator through new power supplies for the poloidal magnetic fields. As a new high level software was needed to implement all this features, the ISTTOK data acquisition system and control has been totally redesigned in JAVA/SQL database technology and time stamps events were adopted to catalogue the data. This software has been design keeping in mind the needs for remote participation and operation of the machine. Therefore, a cooperative environment has been implemented where several persons can be connected together to the platform, programming their own devices and exchanging knowledge or opinions through an embedded chat.

  10. ISTTOK upgrade towards AC and remote operation

    SciTech Connect

    Fernandes, H.; Silva, C.; Carvalho, B.; Sousa, J.; Valcarcel, D.; Neto, A.; Fortunato, J.; Carvalho, I.; Varandas, C. A. F.

    2006-12-04

    ISTTOK has performed one of the earliest experiments of AC tokamak operation showing that long discharges could be produced merely with inductive current drive. However, due to the design of the machine, the data acquisition system and the power supplies, a limit of 250 ms (six times the nominal forward shot duration) is currently imposed.In this paper the relevant constrains to attain current operation up to the limit of the stable toroidal magnetic field (3s) are discussed and the work being carried out to achieve this goal is presented.The conditions that shall be accomplished are: (i) removing the power deposited on the limiters; (ii) density control through gas puffing and monitoring the recycling from the walls; (iii) assessment of the free magnetic flux available on the iron core (Wmax=0.2 Vs); (iv) reformulation of the data acquisition system towards an event driven philosophy maintaining the actual distributed architecture but allowing a real-time control; (v) active control of the equilibrium magnetic fields implementing a digital plasma position estimator and actuator through new power supplies for the poloidal magnetic fields. As a new high level software was needed to implement all this features, the ISTTOK data acquisition system and control has been totally redesigned in JAVA/SQL database technology and time stamps events were adopted to catalogue the data. This software has been design keeping in mind the needs for remote participation and operation of the machine. Therefore, a cooperative environment has been implemented where several persons can be connected together to the platform, programming their own devices and exchanging knowledge or opinions through an embedded chat.

  11. 24 CFR 3280.704 - Fuel supply systems.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Fuel supply systems. 3280.704... URBAN DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Heating, Cooling and Fuel Burning Systems § 3280.704 Fuel supply systems. (a) LP—Gas system design and service line pressure. (1)...

  12. Supply and Demand

    MedlinePlus

    ... a good breastfeeding rhythm with your baby. In reality, the efficient supply-and-demand rhythm of normal ... is one reason it’s a good idea to alternate which breast you use to begin nursing. A ...

  13. Supply options. [hydrogen market

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The use of captive hydrogen (produced and consumed on site) and merchant hydrogen (externally supplied) is considered. A low-merchant-captive ratio market and a high-merchant-captive ratio market are described and compared.

  14. Cleaning supplies and equipment

    MedlinePlus

    ... on any object the person touched or on equipment that was used during their care. Some germs ... why it is important to disinfect supplies and equipment. To disinfect something means to clean it to ...

  15. Tuning magnet power supply

    SciTech Connect

    Han, B.M.; Karady, G.G.; Thiessen, H.A.

    1989-01-01

    The particles in a Rapid Cycling Accelerator are accelerated by rf cavities, which are tuned by dc biased ferrite cores. The tuning is achieved by the regulation of bias current, which is produced by a power supply. The tuning magnet power supply utilizes a bridge circuit, supplied by a three phase rectifier. During the rise of the current, when the particles are accelerated, the current is controlled with precision by the bridge which operates a power amplifier. During the fall of the current, the bridge operates in a switching mode and recovers the energy stored in the ferrites. The recovered energy is stored in a capacitor bank. The bridge circuit is built with 150 power transistors. The drive, protection and control circuit were designed and built from commercial component. The system will be used for a rf cavity experiment in Los Alamos and will serve as a prototype tuning power supply for future accelerators. 1 ref., 7 figs.

  16. Inhibitory effect of açaí (Euterpe oleracea Mart.) pulp on IgE-mediated mast cell activation.

    PubMed

    Horiguchi, Tomoko; Ishiguro, Nahoko; Chihara, Kazuyasu; Ogi, Kazuhiro; Nakashima, Kenji; Sada, Kiyonao; Hori-Tamura, Naoko

    2011-05-25

    The palm fruit açaí is known to have potential health benefits due to its antioxidant scavenging capacities. Pretreatment of IgE-sensitized mouse primary cultured mast cells with açaí pulp resulted in the dramatic suppression of antigen-induced degranulation in a dose-dependent manner. Similarly, açaí suppressed IgE-mediated degranulation and transcription of the cytokine genes from a cultured mast cell line of rat basophilic leukemia (RBL)-2H3 cells. Açaí could selectively inhibit FcεRI signaling pathways. Furthermore, the FcεRI-mediated complementary signaling pathway was also suppressed by açaí. These results demonstrate that açaí is a potent inhibitor of IgE-mediated mast cell activation. PMID:21486000

  17. Cryoresistive gas insulated line

    NASA Astrophysics Data System (ADS)

    Hidaka, K.; Matsumoto, S.; Kouno, T.

    An insulation strength of more than 16 kV mm -1 has been realized using nitrogen gas at 133 K and 0.4 MPa with the application of a.c. and impulse voltages. A cryoresistive gas insulated line (CRGIL) using nitrogen gas is proposed on the basis of the measured insulation strength. An efficient method for use of the cooling heat of liquefied natural gas is also proposed so that no refrigerator is required and the cost of cooling is reduced. The CRGIL has the advantages of having a large current carrying capacity, small power loss and small capacitance. Moreover, a given transmission capacity is achieved by a CRGIL whose rated voltage is about half that in a conventional gas insulated line.

  18. Simultaneous distribution of AC and DC power

    DOEpatents

    Polese, Luigi Gentile

    2015-09-15

    A system and method for the transport and distribution of both AC (alternating current) power and DC (direct current) power over wiring infrastructure normally used for distributing AC power only, for example, residential and/or commercial buildings' electrical wires is disclosed and taught. The system and method permits the combining of AC and DC power sources and the simultaneous distribution of the resulting power over the same wiring. At the utilization site a complementary device permits the separation of the DC power from the AC power and their reconstruction, for use in conventional AC-only and DC-only devices.

  19. Influences of Cry1Ac Broccoli on Larval Survival and Oviposition of Diamondback Moth

    PubMed Central

    Yi, Dengxia; Cui, Shusong; Yang, Limei; Fang, Zhiyuan; Liu, Yumei; Zhuang, Mu; Zhang, Yangyong

    2015-01-01

    Larval survival and oviposition behavior of three genotypes of diamondback moth, Plutella xylostella L. (Lepidoptera: Plutellidae), (homozygous Cry1Ac-susceptibile, Cry1Ac-resistant, and their F1 hybrids), on transgenic Bacillus thuringiensis (Bt) broccoli expressing different levels of Cry1Ac protein were evaluated in laboratory. These Bt broccoli lines were designated as relative low, medium, and high, respectively, according to the Cry1Ac content. Untransformed brocccoli plants were used as control. Larval survival of diamondback moth on non-Bt leaves was not significantly different among the three genotypes. The Cry1Ac-resistant larvae could survive on the low level of Bt broccoli plants, while Cry1Ac-susceptible and F1 larvae could not survive on them. The three genotypes of P. xylostella larvae could not survive on medium and high levels of Bt broccoli. In oviposition choice tests, there was no significant difference in the number of eggs laid by the three P. xylostella genotypes among different Bt broccoli plants. The development of Cry1Ac-susceptible and Cry1Ac-resistant P. xylostella on intact Bt plants was also tested in greenhouse. All susceptible P. xylostella larvae died on all Bt plants, while resistant larvae could survive on broccoli, which expresses low Cry1Ac protein under greenhouse conditions. The results of the greenhouse trials were similar to that of laboratory tests. This study indicated that high dose of Bt toxins in broccoli cultivars or germplasm lines is required for effective resistance management. PMID:25843583

  20. Influences of Cry1Ac broccoli on larval survival and oviposition of diamondback moth.

    PubMed

    Yi, Dengxia; Cui, Shusong; Yang, Limei; Fang, Zhiyuan; Liu, Yumei; Zhuang, Mu; Zhang, Yangyong

    2015-01-01

    Larval survival and oviposition behavior of three genotypes of diamondback moth, Plutella xylostella L. (Lepidoptera: Plutellidae), (homozygous Cry1Ac-susceptibile, Cry1Ac-resistant, and their F1 hybrids), on transgenic Bacillus thuringiensis (Bt) broccoli expressing different levels of Cry1Ac protein were evaluated in laboratory. These Bt broccoli lines were designated as relative low, medium, and high, respectively, according to the Cry1Ac content. Untransformed brocccoli plants were used as control. Larval survival of diamondback moth on non-Bt leaves was not significantly different among the three genotypes. The Cry1Ac-resistant larvae could survive on the low level of Bt broccoli plants, while Cry1Ac-susceptible and F1 larvae could not survive on them. The three genotypes of P. xylostella larvae could not survive on medium and high levels of Bt broccoli. In oviposition choice tests, there was no significant difference in the number of eggs laid by the three P. xylostella genotypes among different Bt broccoli plants. The development of Cry1Ac-susceptible and Cry1Ac-resistant P. xylostella on intact Bt plants was also tested in greenhouse. All susceptible P. xylostella larvae died on all Bt plants, while resistant larvae could survive on broccoli, which expresses low Cry1Ac protein under greenhouse conditions. The results of the greenhouse trials were similar to that of laboratory tests. This study indicated that high dose of Bt toxins in broccoli cultivars or germplasm lines is required for effective resistance management. PMID:25843583

  1. Transgenic Sugarcane with a cry1Ac Gene Exhibited Better Phenotypic Traits and Enhanced Resistance against Sugarcane Borer.

    PubMed

    Gao, Shiwu; Yang, Yingying; Wang, Chunfeng; Guo, Jinlong; Zhou, Dinggang; Wu, Qibin; Su, Yachun; Xu, Liping; Que, Youxiong

    2016-01-01

    We developed sugarcane plants with improved resistance to the sugarcane borer, Diatraea saccharalis (F). An expression vector pGcry1Ac0229, harboring the cry1Ac gene and the selectable marker gene, bar, was constructed. This construct was introduced into the sugarcane cultivar FN15 by particle bombardment. Transformed plantlets were identified after selection with Phosphinothricin (PPT) and Basta. Plantlets were then screened by PCR based on the presence of cry1Ac and 14 cry1Ac positive plantlets were identified. Real-time quantitative PCR (RT-qPCR) revealed that the copy number of cry1Ac gene in the transgenic lines varied from 1 to 148. ELISA analysis showed that Cry1Ac protein levels in 7 transgenic lines ranged from 0.85 μg/FWg to 70.92 μg/FWg in leaves and 0.04 μg/FWg to 7.22 μg/FWg in stems, and negatively correlated to the rate of insect damage that ranged from 36.67% to 13.33%, respectively. Agronomic traits of six transgenic sugarcane lines with medium copy numbers were similar to the non-transgenic parental line. However, phenotype was poor in lines with high or low copy numbers. Compared to the non-transgenic control plants, all transgenic lines with medium copy numbers had relatively equal or lower sucrose yield and significantly improved sugarcane borer resistance, which lowered susceptibility to damage by insects. This suggests that the transgenic sugarcane lines harboring medium copy numbers of the cry1Ac gene may have significantly higher resistance to sugarcane borer but the sugarcane yield in these lines is similar to the non-transgenic control thus making them superior to the control lines. PMID:27093437

  2. Transgenic Sugarcane with a cry1Ac Gene Exhibited Better Phenotypic Traits and Enhanced Resistance against Sugarcane Borer

    PubMed Central

    Gao, Shiwu; Yang, Yingying; Wang, Chunfeng; Guo, Jinlong; Zhou, Dinggang; Wu, Qibin; Su, Yachun; Xu, Liping

    2016-01-01

    We developed sugarcane plants with improved resistance to the sugarcane borer, Diatraea saccharalis (F). An expression vector pGcry1Ac0229, harboring the cry1Ac gene and the selectable marker gene, bar, was constructed. This construct was introduced into the sugarcane cultivar FN15 by particle bombardment. Transformed plantlets were identified after selection with Phosphinothricin (PPT) and Basta. Plantlets were then screened by PCR based on the presence of cry1Ac and 14 cry1Ac positive plantlets were identified. Real-time quantitative PCR (RT-qPCR) revealed that the copy number of cry1Ac gene in the transgenic lines varied from 1 to 148. ELISA analysis showed that Cry1Ac protein levels in 7 transgenic lines ranged from 0.85 μg/FWg to 70.92 μg/FWg in leaves and 0.04 μg/FWg to 7.22 μg/FWg in stems, and negatively correlated to the rate of insect damage that ranged from 36.67% to 13.33%, respectively. Agronomic traits of six transgenic sugarcane lines with medium copy numbers were similar to the non-transgenic parental line. However, phenotype was poor in lines with high or low copy numbers. Compared to the non-transgenic control plants, all transgenic lines with medium copy numbers had relatively equal or lower sucrose yield and significantly improved sugarcane borer resistance, which lowered susceptibility to damage by insects. This suggests that the transgenic sugarcane lines harboring medium copy numbers of the cry1Ac gene may have significantly higher resistance to sugarcane borer but the sugarcane yield in these lines is similar to the non-transgenic control thus making them superior to the control lines. PMID:27093437

  3. Measurements of AC Losses and Current Distribution in Superconducting Cables

    SciTech Connect

    Nguyen, Doan A; Ashworth, Stephen P; Duckworth, Robert C; Carter, Bill; Fleshler, Steven

    2011-01-01

    This paper presents our new experimental facility and techniques to measure ac loss and current distribution between the layers for High Temperature Superconducting (HTS) cables. The facility is powered with a 45 kVA three-phase power supply which can provide three-phase currents up to 5 kA per phase via high current transformers. The system is suitable for measurements at any frequency between 20 and 500 Hz to better understand the ac loss mechanisms in HTS cables. In this paper, we will report techniques and results for ac loss measurements carried out on several HTS cables with and without an HTS shielding layer. For cables without a shielding layer, care must be taken to control the effect of the magnetic fields from return currents on loss measurements. The waveform of the axial magnetic field was also measured by a small pick-up coil placed inside a two-layer cable. The temporal current distribution between the layers can be calculated from the waveform of the axial field.

  4. Scalar control on speed drive for ac motor

    NASA Astrophysics Data System (ADS)

    Barsoum, Nader

    2012-11-01

    This paper aims to investigate the performance of ABB ACS800 variable speed drive operating under Scalar Control mode, and eventually develop a set of experimental procedures for undergraduate laboratory purposes. Scalar Control is the most widespread form of ac drive, for its low cost and simplicity especially implemented in the open loop mode. Scalar control is achieved by controlling the stator voltage and frequency, thus maintaining the motor's air-gap flux at a constant value. To illustrate the control method, the ac drive is configured according to the wiring diagram in the firmware manual that the drive control location can be both local and external. The drive is selected to operate under Factory application macro, whereby either ordinary speed control applications or constant speeds applications may be used. Under ordinary speed control, frequency reference signals are provided to the drive through the analogue input AI1. The drive will operate at the given frequency reference value throughout the operation regardless of any changes in the load. The torque speed curve moves along the speed axis with no changes to the shape as the supply frequencies changes. On the other hand, the drive allows three preset constant speed through digital inputs DI5 and DI6. The drive operate at a constant speed value over a time period, and only switch from one constant speed to another constant speed by triggering the two input switches. Scalar control is most suitable for applications not required high precision, such as blowers, fans and pumps.

  5. Petroleum supply monthly

    SciTech Connect

    1995-10-01

    The Petroleum Supply Monthly (PSM) is one of a family of four publications produced by the Petroleum Supply Division within the Energy Information Administration (EIA) reflecting different levels of data timeliness and completeness. The other publications are the Weekly Petroleum Status Report (WPSR), the Winter Fuels Report, and the Petroleum Supply Annual (PSA). Data presented in the PSM describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blends, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States.

  6. Petroleum Supply Monthly

    SciTech Connect

    1996-02-01

    The Petroleum Supply Monthly (PSM) is one of a family of four publications produced by the Petroleum Supply Division within the Energy Information Administration (EIA) reflecting different levels of data timeliness and completeness. The other publications are the Weekly Petroleum Status Report (WPSR), the Winter Fuels Report, and the Petroleum Supply Annual (PSA). Data presented in the PSM describe the supply and disposition of petroleum products in the United States and major U.S. geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections: Summary Statistics and Detailed Statistics.

  7. Cell Lines

    PubMed Central

    Cherbas, Lucy; Gong, Lei

    2014-01-01

    We review the properties and uses of cell lines in Drosophila research, emphasizing the variety of lines, the large body of genomic and transcriptional data available for many of the lines, and the variety of ways the lines have been used to provide tools for and insights into the developmental, molecular, and cell biology of Drosophila and mammals. PMID:24434506

  8. Chronic intermittent mechanical stress increases MUC5AC protein expression.

    PubMed

    Park, Jin-Ah; Tschumperlin, Daniel J

    2009-10-01

    Increased abundance of mucin secretory cells is a characteristic feature of the epithelium in asthma and other chronic airway diseases. We showed previously that the mechanical stresses of airway constriction, both in the intact mouse lung and a cell culture model, activate the epidermal growth factor receptor (EGFR), a known modulator of mucin expression in airway epithelial cells. Here we tested whether chronic, intermittent, short-duration compressive stress (30 cm H(2)O) is sufficient to increase the abundance of MUC5AC-positive cells and intracellular mucin levels in human bronchial epithelial cells cultured at an air-liquid interface. Compressive stress applied for 1 hour per day for 14 days significantly increased the percentage of cells staining positively for MUC5AC protein (22.0 +/- 3.8%, mean +/- SD) relative to unstimulated controls (8.6 +/- 2.6%), and similarly changed intracellular MUC5AC protein levels measured by Western and slot blotting. The effect of compressive stress was gradual, with significant changes in MUC5AC-positive cell numbers evident by Day 7, but required as little as 10 minutes of compressive stress daily. Daily treatment of cells with an EGFR kinase inhibitor (AG1478, 1 muM) significantly but incompletely attenuated the response to compressive stress. Complete attenuation could be accomplished by simultaneous treatment with the combination of AG1478 and a transforming growth factor (TGF)-beta(2) (1 microg/ml)-neutralizing antibody, or with anti-TGF-beta(2) alone. Our findings demonstrate that short duration episodes of mechanical stress, representative of those occurring during bronchoconstriction, are sufficient to increase goblet cell number and MUC5AC protein expression in bronchial epithelial cells in vitro. We propose that the mechanical environment present in asthma may fundamentally bias the composition of airway epithelial lining in favor of mucin secretory cells. PMID:19168703

  9. Sensorless operation of surface mount permanent magnet AC (PMAC) motors

    SciTech Connect

    Toliyat, H.A.; Rahman, K.M.; Shet, D.S.

    1999-12-01

    A sensorless field oriented control scheme for surface mount permanent magnet ac (PMAC) motor with split phase stator windings is presented. This motor is obtained by splitting the phase windings of a conventional three phase motor. The six-phase motor, however is run as a three-phase motor by connecting the split phase stator windings in series, while the taps are made available for voltage measurements. By measuring the terminal voltages and the line currents, absolute position of the permanent magnet ac motor driven by a current regulated PWM inverter with a hysteresis controller is estimated. The estimated position information is independent of the stator resistance, thus this scheme is even applicable at low speeds. Results are presented to show the effectiveness of the new controller, and it is also shown that the position error is negligible.

  10. Coal supply for California

    NASA Technical Reports Server (NTRS)

    Yancik, J. J.

    1978-01-01

    The potential sources and qualities of coals available for major utility and industrial consumers in California are examined and analyzed with respect to those factors that would affect the reliability of supplies. Other considerations, such as the requirements and assurances needed by the coal producers to enter into long-term contracts and dedicate large reserves of coal to these contracts are also discussed. Present and potential future mining contraints on coal mine operators are identified and analyzed with respect to their effect on availability of supply.

  11. Modified filter prevents conduction of microwave signals along high-voltage power supply leads

    NASA Technical Reports Server (NTRS)

    Mathison, R. P.

    1964-01-01

    Very lossy powdered iron material, in the lining of a polyester resin, replaces the dielectric material in the short coaxial transmission line of a simple filter. The lossy material absorbs microwave signals along high voltage power supply leads.

  12. Germinal and Somatic Activity of the Maize Element Activator (Ac) in Arabidopsis

    PubMed Central

    Keller, J.; Lim, E.; James-Jr., D. W.; Dooner, H. K.

    1992-01-01

    We have investigated the germinal and somatic activity of the maize Activator (Ac) element in Arabidopsis with the objective of developing an efficient transposon-based system for gene isolation in that plant. Transposition activity was assayed with a chimeric marker that consists of the cauliflower mosaic virus 35S promoter and a bacterial streptomycin phosphotransferase gene (SPT). Somatic activity was detected in seedlings germinated on plates containing streptomycin as green-resistant sectors against a background of white-sensitive cells. Germinal excisions resulted in fully green seedlings. The transposition frequency was extremely low when a single copy of the transposon was present, but appeared to increase with an increase in Ac copy number. Plants that were selected as variegated produced an increased number of green progeny. The methylation state of the Ac elements in lines with either low or high levels of excision was assessed by restriction analysis. No difference was found between these lines, indicating that the degree of methylation did not contribute to the level of Ac activity. Germinal excision events were analyzed molecularly and shown to carry reinserted transposons in about 50% of the cases. In several instances, streptomycin-resistant siblings carried the same transposed Ac element, indicating that excision had occurred prior to meiosis in the parent. We discuss parameters that need to be considered to optimize the use of Ac as a transposon tag in Arabidopsis. PMID:1322854

  13. Overview of the ATR Power Supplies

    NASA Astrophysics Data System (ADS)

    Bruno, D.; Soukas, A.; Toldo, F.; Lambiase, B.

    1997-05-01

    The AGS to RHIC transfer Line (ATR) transports a variety of beams from the Alternating Gradient Synchrotron (AGS) which gets its input from the Booster Synchrotron. In turn, the Booster receives input beams from either a Tandem Van de Graaff (heavy ions) or a Linac(protons). The AGS extracts beam bunches, up to a rate of 30 Hertz, to the ATR which will eventually feed the Relativistic Heavy Ion Collider (RHIC) starting with the sextant test in January of 1996. The ATR is made up of the upgraded U line and the new W, X and Y lines. A test in 1995 transported beam to the end of the W line. During normal operation, a pulsed switching magnet at the end of the W line will bend the beam into the X line or the Y line so that the two rings in RHIC are filled with counter rotating beams. The ATR line is comprised of 80 power supplies (PS's), 17 of which are upgraded AGS PS's. The remaining 63 PS's were newly purchased. These PS's range from bipolar 600 watt linear type trim magnet PS's to 1 Megawatt, thyristor, dipole PS's. Results of the commissioning runs will be presented, as well as descriptions of regulation, filtering, and analog and digital controls.

  14. Overview of the ATR power supplies

    SciTech Connect

    Bruno, D.; Soukas, A.; Toldo, F.; Lambiase, R.F.

    1997-07-01

    The AGS to RHIC transfer line (ATR) transports a variety of beams from the Alternating Gradient Synchrotron (AGS) which gets its input from the Booster Synchrotron. In turn, the Booster receives input beams from either a Tandem Van de Graaff (heavy ions) or a Linac (protons). The AGS extracts beam bunches, up to a rate of 30 Hertz, to the ATR which feeds the Relativistic Heavy Ion Collider (RHIC) starting with the sextant test in January of 1997. The ATR is made up of the upgraded U line and the new W, X, and Y lines. A test in 1995 transported beam to the end of the W line. During normal operation, a pulsed switching magnet at the end of the W line will bend the beam into the X line or the Y line so that the two storage rings in RHIC are filled with counter rotating beams. The ATR line is comprised of 80 power supplies (PS`s), 17 of which are upgraded AGS PS`s. The remaining 63 PS`s were newly purchased. These PS`s range from bipolar 600 watt linear type trim magnet PS`s to 1 Megawatt, thyristor, dipole PS`s. Results of the commissioning runs will be presented, as well as descriptions of regulation, filtering, and analog and digital controls.

  15. Electrical and Biological Effects of Transmission Lines: A Review.

    SciTech Connect

    Lee, Jack M.

    1989-06-01

    This review describes the electrical properties of a-c and d-c transmission lines and the resulting effects on plants, animals, and people. Methods used by BPA to mitigate undesirable effects are also discussed. Although much of the information in this review pertains to high-voltage transmission lines, information on distribution lines and electrical appliances is included. The electrical properties discussed are electric and magnetic fields and corona: first for alternating-current (a-c) lines, then for direct current (d-c).

  16. Supply-Chain Optimization Template

    NASA Technical Reports Server (NTRS)

    Quiett, William F.; Sealing, Scott L.

    2009-01-01

    The Supply-Chain Optimization Template (SCOT) is an instructional guide for identifying, evaluating, and optimizing (including re-engineering) aerospace- oriented supply chains. The SCOT was derived from the Supply Chain Council s Supply-Chain Operations Reference (SCC SCOR) Model, which is more generic and more oriented toward achieving a competitive advantage in business.

  17. Ac electrode diagnostics in ac-operated metal halide lamps

    NASA Astrophysics Data System (ADS)

    Luijks, G. M. J. F.; van Esveld, H. A.; Nijdam, S.; Weerdesteijn, P. A. M.

    2008-07-01

    A diagnostic technique is presented to determine the electrode work function in ac-operated metal halide lamps. The heart of the experimental set-up is a high-speed photodiode array detector, which is able to follow real-time variations of electrode tip temperature and near-electrode plasma emissions in ac-operated experimental YAG lamps, enabling discrimination between the anode and cathode effects. Electrode tip temperature ripples have been measured for 100 Hz square wave operation and simulated with an existing electrode model. By using the electrode work function as main fit parameter for the simulations it is found that the measured cooling effect of the electrode tip in a NaTlDy-iodide lamp is caused by a gas-phase emitter effect of Dy. It is concluded that Dy coverage of the electrode tip causes an effective work function reduction of 0.3 eV at 100 Hz square wave operation, considerably less than the 1.0 eV reduction measured earlier for dc operation.

  18. Ethics of Information Supply.

    ERIC Educational Resources Information Center

    Oppenheim, Charles

    This discussion of the ethics of the information process provides a brief review of the process of information supply and flow, primarily in science and technology; looks at various points in the flow of information; and highlights particular ethical concerns. Facets of the process discussed in more detail include ways in which some scientists…

  19. Exploration Supply Chain Simulation

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Exploration Supply Chain Simulation project was chartered by the NASA Exploration Systems Mission Directorate to develop a software tool, with proper data, to quantitatively analyze supply chains for future program planning. This tool is a discrete-event simulation that uses the basic supply chain concepts of planning, sourcing, making, delivering, and returning. This supply chain perspective is combined with other discrete or continuous simulation factors. Discrete resource events (such as launch or delivery reviews) are represented as organizational functional units. Continuous resources (such as civil service or contractor program functions) are defined as enabling functional units. Concepts of fixed and variable costs are included in the model to allow the discrete events to interact with cost calculations. The definition file is intrinsic to the model, but a blank start can be initiated at any time. The current definition file is an Orion Ares I crew launch vehicle. Parameters stretch from Kennedy Space Center across and into other program entities (Michaud Assembly Facility, Aliant Techsystems, Stennis Space Center, Johnson Space Center, etc.) though these will only gain detail as the file continues to evolve. The Orion Ares I file definition in the tool continues to evolve, and analysis from this tool is expected in 2008. This is the first application of such business-driven modeling to a NASA/government-- aerospace contractor endeavor.

  20. Lightweight Regulated Power Supply

    NASA Technical Reports Server (NTRS)

    Mclyman, C. W.

    1985-01-01

    Power-supply circuit regulates output voltage by adjusting frequency of chopper circuit according to variations. Currently installed in battery charger for electric wheelchair, circuit is well suited to other uses in which light weight is important - for example, in portable computers, radios, and test instruments.

  1. Maintenance and supply options

    NASA Technical Reports Server (NTRS)

    1988-01-01

    The object of the Maintenance and Supply Option was to develop a high level operational philosophy related to maintenance and supply operations and incorporate these concepts into the Lunar Base Study. Specific products to be generated during this task were three trade studies and a conceptual design of the Logistic Supply Module. The crew size study was performed to evaluate crew sizes from the baseline size of four to a crew size of eight and determine the preferred crew size. The second trade study was to determine the impact of extending surface stay times and recommend a preferred duration of stay time as a function of crew, consumables, and equipment support capabilities. The third trade study was an evaluation of packaging and storage methods to determine the preferred logistics approach to support the lunar base. A modified scenario was developed and served as the basis of the individual trade studies. Assumptions and guidelines were also developed from experience with Apollo programs, Space Shuttle operations, and Space Station studies. With this information, the trade studies were performed and a conceptual design for the Logistic Supply Module was developed.

  2. APS power supply controls

    SciTech Connect

    Saunders, C.W.; Despe, O.D.

    1994-03-31

    The purpose of this document is to provide comprehensive coverage of the APS power supply control design. This includes application software, embedded controller software, networks, and hardware. The basic components will be introduced first, followed by the requirements driving the overall design. Subsequent sections will address each component of the design one by one. Latter sections will address specific applications.

  3. Measurements and calculations of transport AC loss in second generation high temperature superconducting pancake coils

    NASA Astrophysics Data System (ADS)

    Yuan, Weijia; Coombs, T. A.; Kim, Jae-Ho; Han Kim, Chul; Kvitkovic, Jozef; Pamidi, Sastry

    2011-12-01

    Theoretical and experimental AC loss data on a superconducting pancake coil wound using second generation (2 G) conductors are presented. An anisotropic critical state model is used to calculate critical current and the AC losses of a superconducting pancake coil. In the coil there are two regions, the critical state region and the subcritical region. The model assumes that in the subcritical region the flux lines are parallel to the tape wide face. AC losses of the superconducting pancake coil are calculated using this model. Both calorimetric and electrical techniques were used to measure AC losses in the coil. The calorimetric method is based on measuring the boil-off rate of liquid nitrogen. The electric method used a compensation circuit to eliminate the inductive component to measure the loss voltage of the coil. The experimental results are consistent with the theoretical calculations thus validating the anisotropic critical state model for loss estimations in the superconducting pancake coil.

  4. Power Supplies for Precooler Ring

    SciTech Connect

    Fuja, Raymond; Praeg, Walter

    1980-12-12

    Eight power supplies will energize the antiproton Precooler ring. there will be two series connected supplies per quadrant. These supplies will power 32 dipole and 19 quadrupole magnets. The resistance and inductance per quadrant is R = 1.4045 Ohms and L = 0.466. Each powr supply will have 12-phase series bridge rectifiers and will be energized from the 480 V 3-phase grid. The total of eight power supplies are numbered IA, IIA, IIIA, IVA, and IB, IIB, IIIB, and IVB. Each quadrant will contain one A and one B supply. A block diagram of the Precooler ring with its power supplies is shown in Figure 1.

  5. The AC photovoltaic module is here!

    NASA Astrophysics Data System (ADS)

    Strong, Steven J.; Wohlgemuth, John H.; Wills, Robert H.

    1997-02-01

    This paper describes the design, development, and performance results of a large-area photovoltaic module whose electrical output is ac power suitable for direct connection to the utility grid. The large-area ac PV module features a dedicated, integrally mounted, high-efficiency dc-to-ac power inverter with a nominal output of 250 watts (STC) at 120 Vac, 60 H, that is fully compatible with utility power. The module's output is connected directly to the building's conventional ac distribution system without need for any dc wiring, string combiners, dc ground-fault protection or additional power-conditioning equipment. With its advantages, the ac photovoltaic module promises to become a universal building block for use in all utility-interactive PV systems. This paper discusses AC Module design aspects and utility interface issues (including islanding).

  6. Development of a dc 1 MV power supply technology for NB injectors

    NASA Astrophysics Data System (ADS)

    Watanabe, K.; Kashiwagi, M.; Kawashima, S.; Ono, Y.; Yamashita, Y.; Yamazaki, C.; Hanada, M.; Inoue, T.; Taniguchi, M.; Okumura, Y.; Sakamoto, K.

    2006-06-01

    Major issues of neutral beam (NB) injector power supplies are high-speed switching, regulation and transmission of dc ultra-high voltage (UHV) and suppression of surge energy input to the beam source at high voltage breakdown. A gate turn-off thyristor inverter type power supply where the control is performed on the low voltage ac side was designed for the ITER NB. Based on the remarkable progress of a high power IEGT (injection enhanced gate transistor), the design of the inverter has been modified to increase efficiency and compactness using such new elements. The power loss in the inverter is reduced to 0.5 MW from 1.6 MW by adopting the IEGT inverter system at the same frequency of 150 Hz. Further, power supply performance has been studied for higher frequency operation of the inverter at 300 Hz. It was confirmed that the voltage regulation was stable even when the filter capacitor was reduced to 1/5 of the original value by circuit simulation. For the transmission line of the dc UHV with intermediate voltages, a disc shape multi-conductor bushing with a transmission line test chamber has been developed. The dimensions of the bushing are 1.8 m (diameter) and 140 mm (thickness) at the edge. Electric fields at the conductor surface and insulator surface were designed to be lower than 5 kV mm-1 and 7 kV mm-1, respectively. An electric field at the bottom of the ground potential outer conductor was designed to be lower than 1.2 kV mm-1 to prevent particle levitation which triggers breakdown. The prototype transmission line has passed the lightning impulse test up to 1300 kV. A dc UHV up to 1175 kV was successfully sustained for 300 s. To prevent electric damage of the beam source at high voltage breakdown, core snubbers using Fe-based nanocrystalline soft magnetic materials have been adopted to dissipate the surge energy.

  7. Pixel-based CTE Correction of ACS/WFC: Potential Benefits from Charge Injection

    NASA Astrophysics Data System (ADS)

    Golimowski, David A.; Anderson, J.; Smith, L. J.; MacKenty, J.; Cheng, E.; Waczynski, A.; Graham, E.; Wilson, E.; Mazzuca, L.; Loose, M.

    2012-01-01

    The implementation of charge injection (CI) as a means of mitigating charge transfer inefficiency (CTI) in HST's WFC3/UVIS channel has inspired us to study the possible use of CI with HST's ACS/WFC channel and its potential benefit to subsequent CTI correction with the pixel-based algorithm of Anderson & Bedin. We have achieved substantial CTI mitigation in the laboratory using both continuous and discrete line injection modes of CI with an irradiated engineering-grade ACS/WFC CCD. Although the mitigation and noise characteristics of the line injection are favorable for scientific use in the regime of very low natural sky background (< 10 e-/pix) as is prevalent in WFC3/UVIS exposures, line injection is not practical for the vast majority of ACS/WFC science exposures, which have backgrounds of 40-150 e-/pix. Moreover, the short average release time of ACS/WFC charge traps precludes uniform mitigation in the interline regions and significantly complicates science data analysis. On the other hand, a continuous injection (or "flood") of several hundred electrons with noise ≤ 7 e- would uniformly limit CTI to 20% at all signal levels and pixel locations while only minimally affecting the signal-to-noise ratios of the sources. Such CTI losses could subsequently be corrected by the pixel-based algorithm to better than 5%. If such CI is achievable, it could become the default operating mode for ACS exposures in future observing cycles.

  8. The Ethylene Biosynthesis Gene CitACS4 Regulates Monoecy/Andromonoecy in Watermelon (Citrullus lanatus)

    PubMed Central

    Manzano, Susana; Aguado, Encarnación; Martínez, Cecilia; Megías, Zoraida; García, Alicia; Jamilena, Manuel

    2016-01-01

    Monoecious and andromonoecious cultivars of watermelon are characterised by the production of male and female flower or male and hermaphrodite flowers, respectively. The segregation analysis in the offspring of crosses between monoecious and andromonoecious lines has demonstrated that this trait is controlled by a single gene pair, being the monoecious allele M semi-dominant to the andromonoecious allele A. The two studied F1 hybrids (MA) had a predominantly monoecious phenotype since both produced not only female flowers, but also bisexual flowers with incomplete stamens, and hermaphrodite flowers with pollen. Given that in other cucurbit species andromonoecy is conferred by mutations in the ethylene biosynthesis genes CmACS7, CsACS2 and CpACS27A we have cloned and characterised CitACS4, the watermelon gene showing the highest similarity with the formers. CitACS4 encoded for a type ACS type III enzyme that is predominantly expressed in pistillate flowers of watermelon. In the andromonoecious line we have detected a missense mutation in a very conserved residue of CitACS4 (C364W) that cosegregates with the andromonoecious phenotype in two independent F2 populations, concomitantly with a reduction in ethylene production in the floral buds that will develop as hermaphrodite flowers. The gene does not however co-segregates with other sex expression traits regulated by ethylene in this species, including pistillate flowering transition and the number of pistillate flowers per plant. These data indicate that CitAC4 is likely to be involved in the biosynthesis of the ethylene required for stamen arrest during the development of female flowers. The C364W mutation would reduce the production of ethylene in pistillate floral buds, promoting the conversion of female into hermaphrodite flowers, and therefore of monoecy into andromonoecy. PMID:27149159

  9. The Ethylene Biosynthesis Gene CitACS4 Regulates Monoecy/Andromonoecy in Watermelon (Citrullus lanatus).

    PubMed

    Manzano, Susana; Aguado, Encarnación; Martínez, Cecilia; Megías, Zoraida; García, Alicia; Jamilena, Manuel

    2016-01-01

    Monoecious and andromonoecious cultivars of watermelon are characterised by the production of male and female flower or male and hermaphrodite flowers, respectively. The segregation analysis in the offspring of crosses between monoecious and andromonoecious lines has demonstrated that this trait is controlled by a single gene pair, being the monoecious allele M semi-dominant to the andromonoecious allele A. The two studied F1 hybrids (MA) had a predominantly monoecious phenotype since both produced not only female flowers, but also bisexual flowers with incomplete stamens, and hermaphrodite flowers with pollen. Given that in other cucurbit species andromonoecy is conferred by mutations in the ethylene biosynthesis genes CmACS7, CsACS2 and CpACS27A we have cloned and characterised CitACS4, the watermelon gene showing the highest similarity with the formers. CitACS4 encoded for a type ACS type III enzyme that is predominantly expressed in pistillate flowers of watermelon. In the andromonoecious line we have detected a missense mutation in a very conserved residue of CitACS4 (C364W) that cosegregates with the andromonoecious phenotype in two independent F2 populations, concomitantly with a reduction in ethylene production in the floral buds that will develop as hermaphrodite flowers. The gene does not however co-segregates with other sex expression traits regulated by ethylene in this species, including pistillate flowering transition and the number of pistillate flowers per plant. These data indicate that CitAC4 is likely to be involved in the biosynthesis of the ethylene required for stamen arrest during the development of female flowers. The C364W mutation would reduce the production of ethylene in pistillate floral buds, promoting the conversion of female into hermaphrodite flowers, and therefore of monoecy into andromonoecy. PMID:27149159

  10. RHIC spin flipper AC dipole controller

    SciTech Connect

    Oddo, P.; Bai, M.; Dawson, C.; Gassner, D.; Harvey, M.; Hayes, T.; Mernick, K.; Minty, M.; Roser, T.; Severino, F.; Smith, K.

    2011-03-28

    The RHIC Spin Flipper's five high-Q AC dipoles which are driven by a swept frequency waveform require precise control of phase and amplitude during the sweep. This control is achieved using FPGA based feedback controllers. Multiple feedback loops are used to and dynamically tune the magnets. The current implementation and results will be presented. Work on a new spin flipper for RHIC (Relativistic Heavy Ion Collider) incorporating multiple dynamically tuned high-Q AC-dipoles has been developed for RHIC spin-physics experiments. A spin flipper is needed to cancel systematic errors by reversing the spin direction of the two colliding beams multiple times during a store. The spin flipper system consists of four DC-dipole magnets (spin rotators) and five AC-dipole magnets. Multiple AC-dipoles are needed to localize the driven coherent betatron oscillation inside the spin flipper. Operationally the AC-dipoles form two swept frequency bumps that minimize the effect of the AC-dipole dipoles outside of the spin flipper. Both AC bumps operate at the same frequency, but are phase shifted from each other. The AC-dipoles therefore require precise control over amplitude and phase making the implementation of the AC-dipole controller the central challenge.

  11. An electrohydrodynamic flow in ac electrowetting

    PubMed Central

    Lee, Horim; Yun, Sungchan; Ko, Sung Hee; Kang, Kwan Hyoung

    2009-01-01

    In ac electrowetting, hydrodynamic flows occur within a droplet. Two distinct flow patterns were observed, depending on the frequency of the applied electrical signal. The flow at low-frequency range was explained in terms of shape oscillation and a steady streaming process in conjunction with contact line oscillation. The origin of the flow at high-frequency range has not yet been explained. We suggest that the high-frequency flow originated mainly from the electrothermal effect, in which electrical charge is generated due to the gradient of electrical conductivity and permittivity, which is induced by the Joule heating of fluid medium. To support our argument, we analyzed the flow field numerically while considering the electrical body force generated by the electrothermal effect. We visualized the flow pattern and measured the flow velocity inside the droplet. The numerical results show qualitative agreement with experimental results with respect to electric field and frequency dependence of flow velocity. The effects of induced-charge electro-osmosis, natural convection, and the Marangoni flow are discussed. PMID:20216975

  12. An electrohydrodynamic flow in ac electrowetting.

    PubMed

    Lee, Horim; Yun, Sungchan; Ko, Sung Hee; Kang, Kwan Hyoung

    2009-01-01

    In ac electrowetting, hydrodynamic flows occur within a droplet. Two distinct flow patterns were observed, depending on the frequency of the applied electrical signal. The flow at low-frequency range was explained in terms of shape oscillation and a steady streaming process in conjunction with contact line oscillation. The origin of the flow at high-frequency range has not yet been explained. We suggest that the high-frequency flow originated mainly from the electrothermal effect, in which electrical charge is generated due to the gradient of electrical conductivity and permittivity, which is induced by the Joule heating of fluid medium. To support our argument, we analyzed the flow field numerically while considering the electrical body force generated by the electrothermal effect. We visualized the flow pattern and measured the flow velocity inside the droplet. The numerical results show qualitative agreement with experimental results with respect to electric field and frequency dependence of flow velocity. The effects of induced-charge electro-osmosis, natural convection, and the Marangoni flow are discussed. PMID:20216975

  13. Vortex activation energy in the AC magnetic response of superconducting YBa2Cu3O7 thin films with complex pinning structures

    NASA Astrophysics Data System (ADS)

    Ivan, I.; Ionescu, A. M.; Miu, D.; Mele, P.; Miu, L.

    2016-09-01

    The vortex activation energy U AC in the AC magnetic response of superconductors exhibits a logarithmic variation with the screening current density J (regardless of the pinning structure details), and takes surprisingly high values in the vicinity of the DC irreversibility line, especially at low external DC magnetic fields, as often reported. This is essentially different from the behaviour of the vortex-creep activation energy at long relaxation time scales in DC magnetic measurements, and is not completely understood. We investigated the DC relaxation and the AC response for YBa2Cu3O7 films containing nanorods and nanoparticles, with the DC and AC fields oriented perpendicular to the film surface. It is shown that the large U AC values in the vicinity of the DC irreversibility line, where the critical-state-related AC signal occurs, are generated by a non-diffusive vortex motion during the AC cycle, with the mean vortex hopping length longer than the average distance between the pinning centres. In these conditions, the smearing of the vortex pinning potential by thermally induced vortex fluctuations is weak, and U AC mainly results from the strong influence of the pinning-enhanced viscous drag on the vortex hopping process. The logarithmic U AC(J) dependence is consistent with a high U AC.

  14. ac electroosmosis in rectangular microchannels.

    PubMed

    Campisi, Michele; Accoto, Dino; Dario, Paolo

    2005-11-22

    Motivated by the growing interest in ac electroosmosis as a reliable no moving parts strategy to control fluid motion in microfluidic devices for biomedical applications, such as lab-on-a-chip, we study transient and steady-state electrokinetic phenomena (electroosmosis and streaming currents) in infinitely extended rectangular charged microchannels. With the aid of Fourier series and Laplace transforms we provide a general formal solution of the problem, which is used to study the time-dependent response to sudden ac applied voltage differences in case of finite electric double layer. The Debye-Huckel approximation has been adopted to allow for an algebraic solution of the Poisson-Boltzmann problem in Fourier space. We obtain the expressions of flow velocity profiles, flow rates, streaming currents, as well as expressions of the complex hydraulic and electrokinetic conductances. We analyze in detail the dependence of the electrokinetic conductance on the extension of linear dimensions relative to the Debye length, with an eye on finite electric double layer effects. PMID:16351310

  15. Single event AC - DC electrospraying

    NASA Astrophysics Data System (ADS)

    Stachewicz, U.; Dijksman, J. F.; Marijnissen, J. C. M.

    2008-12-01

    Electrospraying is an innovative method to deposit very small amounts of, for example, biofluids (far less than 1 p1) that include DNA or protein molecules. An electric potential is applied between a nozzle filled with liquid and a counter electrode placed at 1-2 millimeter distance from the nozzle. In our set-up we use an AC field superposed on a DC field to control the droplet generation process. Our approach is to create single events of electrospraying triggered by one single AC pulse. During this pulse, the equilibrium meniscus (determined by surface tension, static pressure and the DC field) of the liquid changes rapidly into a cone and subsequently into a jet formed at the cone apex. Next, the jet breaks-up into fine droplets and the spraying stops. The meniscus returns to its equilibrium shape again. So far we obtained a stable and reproducible single event process for ethanol and ethylene glycol with water using glass pipettes. The results will be used to generate droplets on demand in a controlled way and deposit them on a pre-defined place on the substrate.

  16. Power control for ac motor

    NASA Technical Reports Server (NTRS)

    Dabney, R. W. (Inventor)

    1984-01-01

    A motor controller employing a triac through which power is supplied to a motor is described. The open circuit voltage appearing across the triac controls the operation of a timing circuit. This timing circuit triggers on the triac at a time following turn off which varies inversely as a function of the amplitude of the open circuit voltage of the triac.

  17. Reotemp Pressure Indicator Local Pressure Indication to Monitor the SCHE Supply Bottle Pressure

    SciTech Connect

    VAN KATWIJK, C.

    1999-07-01

    These 0-3000 psig range pressure indicators are located in the SCHe helium supply lines at the pressure bottles and upstream of the PRV. These accident monitoring local pressure indicators monitor the SCHe supply bottle pressure. There is one pressure indicator for each SCHe supply (4).

  18. Measure Lines

    ERIC Educational Resources Information Center

    Crissman, Sally

    2011-01-01

    One tool for enhancing students' work with data in the science classroom is the measure line. As a coteacher and curriculum developer for The Inquiry Project, the author has seen how measure lines--a number line in which the numbers refer to units of measure--help students not only represent data but also analyze it in ways that generate…

  19. APN1 is a functional receptor of Cry1Ac but not Cry2Ab in Helicoverpa zea

    PubMed Central

    Wei, Jizhen; Zhang, Min; Liang, Gemei; Wu, Kongming; Guo, Yuyuan; Ni, Xinzhi; Li, Xianchun

    2016-01-01

    Lepidopteran midgut aminopeptidases N (APNs) are phylogenetically divided into eight clusters, designated as APN1–8. Although APN1 has been implicated as one of the receptors for Cry1Ac in several species, its potential role in the mode of action of Cry2Ab has not been functionally determined so far. To test whether APN1 also acts as one of the receptors for Cry1Ac in Helicoverpa zea and even for Cry2Ab in this species, we conducted a gain of function analysis by heterologously expressing H. zea APN1 (HzAPN1) in the midgut and fat body cell lines of H. zea and the ovarian cell line of Spodoptera frugiperda (Sf9) and a loss of function analysis by RNAi (RNA interference) silencing of the endogenous APN1 in the three cell lines using the HzAPN1 double strand RNA (dsRNA). Heterologous expression of HzAPN1 significantly increased the susceptibility of the three cell lines to Cry1Ac, but had no effects on their susceptibility to Cry2Ab. Knocking down of the endogenous APN1 made the three cell lines resistant to Cry1Ac, but didn’t change cell lines susceptibility to Cry2Ab. The findings from this study demonstrate that HzAPN1 is a functional receptor of Cry1Ac, but not Cry2Ab. PMID:26755166

  20. Improving thrust by pulse-induced breakdown enhancement in AC surface dielectric barrier discharge actuators for airflow control

    NASA Astrophysics Data System (ADS)

    Yan, Huijie; Yang, Liang; Qi, Xiaohua; Ren, Chunsheng

    2016-07-01

    The characteristics of a plate-to-plate AC surface dielectric barrier discharge (SDBD) actuator using the pulse-induced breakdown enhancing method are experimentally investigated. The encapsulated electrode is supplied with a sine high AC voltage, while the exposed electrode is feed by a synchronized pulse voltage. Based on the thrust force and power consumption measurements, a parametric study was performed using a positive pulse applied at the trough phase of the AC cycles in which the thrust force was observed to increase by about 100% to 300% and the efficiency up to about 100% compared with the AC-only supply conditions for different AC voltages within the tested range. The pulse-induced breakdown effect was analyzed from the electrical and light emission waveforms to reveal the underlying mechanism. The surface potential due to the charge deposition effect was also measured using a specially designed corona-like discharge potential probe. It is shown that the pulse-induced breakdown was able to cause a temporarily intensified local electric field to enhance the glow-like discharge and meanwhile increase the time-average surface potential in the region further downstream. The improvement in the force by the enhancement in the pulse-induced breakdown was mainly due to enhancements in the glow-like discharge and the surface potential increment, with the latter being more important when the AC voltage is higher.

  1. High voltage power supply

    NASA Technical Reports Server (NTRS)

    Ruitberg, A. P.; Young, K. M. (Inventor)

    1985-01-01

    A high voltage power supply is formed by three discrete circuits energized by a battery to provide a plurality of concurrent output signals floating at a high output voltage on the order of several tens of kilovolts. In the first two circuits, the regulator stages are pulse width modulated and include adjustable ressistances for varying the duty cycles of pulse trains provided to corresponding oscillator stages while the third regulator stage includes an adjustable resistance for varying the amplitude of a steady signal provided to a third oscillator stage. In the first circuit, the oscillator, formed by a constant current drive network and a tuned resonant network included a step up transformer, is coupled to a second step up transformer which, in turn, supplies an amplified sinusoidal signal to a parallel pair of complementary poled rectifying, voltage multiplier stages to generate the high output voltage.

  2. Discontinuous Mode Power Supply

    NASA Technical Reports Server (NTRS)

    Lagadinos, John; Poulos, Ethel

    2012-01-01

    A document discusses the changes made to a standard push-pull inverter circuit to avoid saturation effects in the main inverter power supply. Typically, in a standard push-pull arrangement, the unsymmetrical primary excitation causes variations in the volt second integral of each half of the excitation cycle that could lead to the establishment of DC flux density in the magnetic core, which could eventually cause saturation of the main inverter transformer. The relocation of the filter reactor normally placed across the output of the power supply solves this problem. The filter reactor was placed in series with the primary circuit of the main inverter transformer, and is presented as impedance against the sudden changes on the input current. The reactor averaged the input current in the primary circuit, avoiding saturation of the main inverter transformer. Since the implementation of the described change, the above problem has not reoccurred, and failures in the main power transistors have been avoided.

  3. A Switching-Mode Power Supply Design Tool to Improve Learning in a Power Electronics Course

    ERIC Educational Resources Information Center

    Miaja, P. F.; Lamar, D. G.; de Azpeitia, M.; Rodriguez, A.; Rodriguez, M.; Hernando, M. M.

    2011-01-01

    The static design of ac/dc and dc/dc switching-mode power supplies (SMPS) relies on a simple but repetitive process. Although specific spreadsheets, available in various computer-aided design (CAD) programs, are widely used, they are difficult to use in educational applications. In this paper, a graphic tool programmed in MATLAB is presented,…

  4. Streamlining the supply chain.

    PubMed

    Neumann, Lydon

    2003-07-01

    Effective management of the supply chain requires attention to: Product management--formulary development and maintenance, compliance, clinical involvement, standardization, and demand-matching. Sourcing and contracting--vendor consolidation, GPO portfolio management, price leveling, content management, and direct contracting Purchasing and payment-cycle--automatic placement, web enablement, centralization, evaluated receipts settlement, and invoice matching Inventory and distribution management--"unofficial" and "official" locations, vendor-managed inventory, automatic replenishment, and freight management. PMID:12866156

  5. Mobile Uninterruptible Power Supply

    NASA Technical Reports Server (NTRS)

    Mears, Robert L.

    1990-01-01

    Proposed mobile unit provides 20 kVA of uninterruptible power. Used with mobile secondary power-distribution centers to provide power to test equipment with minimal cabling, hazards, and obstacles. Wheeled close to test equipment and system being tested so only short cable connections needed. Quickly moved and set up in new location. Uninterruptible power supply intended for tests which data lost or equipment damaged during even transient power failure.

  6. Cry1Ac Transgenic Sugarcane Does Not Affect the Diversity of Microbial Communities and Has No Significant Effect on Enzyme Activities in Rhizosphere Soil within One Crop Season

    PubMed Central

    Zhou, Dinggang; Xu, Liping; Gao, Shiwu; Guo, Jinlong; Luo, Jun; You, Qian; Que, Youxiong

    2016-01-01

    Cry1Ac transgenic sugarcane provides a promising way to control stem-borer pests. Biosafety assessment of soil ecosystem for cry1Ac transgenic sugarcane is urgently needed because of the important role of soil microorganisms in nutrient transformations and element cycling, however little is known. This study aimed to explore the potential impact of cry1Ac transgenic sugarcane on rhizosphere soil enzyme activities and microbial community diversity, and also to investigate whether the gene flow occurs through horizontal gene transfer. We found no horizontal gene flow from cry1Ac sugarcane to soil. No significant difference in the population of culturable microorganisms between the non-GM and cry1Ac transgenic sugarcane was observed, and there were no significant interactions between the sugarcane lines and the growth stages. A relatively consistent trend at community-level, represented by the functional diversity index, was found between the cry1Ac sugarcane and the non-transgenic lines. Most soil samples showed no significant difference in the activities of four soil enzymes: urease, protease, sucrose, and acid phosphate monoester between the non-transgenic and cry1Ac sugarcane lines. We conclude, based on one crop season, that the cry1Ac sugarcane lines may not affect the microbial community structure and functional diversity of the rhizosphere soil and have few negative effects on soil enzymes. PMID:27014291

  7. AC electrokinetic manipulation of selenium nanoparticles for potential nanosensor applications

    SciTech Connect

    Mahmoodi, Seyed Reza; Bayati, Marzieh; Hosseinirad, Somayeh; Foroumadi, Alireza; Gilani, Kambiz; Rezayat, Seyed Mahdi

    2013-03-15

    Highlights: ► Se nanoparticles were synthesized using a reverse-microemulsion process. ► AC osmotic fluid flow repulses the particles from electrode edges. ► Dielectrophoretic force attracts the particles to electrode edges. ► Dielectrophoresis electrode showed non-ohmic behavior. ► The device can potentially be used as a nanosensor. - Abstract: We report the AC electrokinetic behavior of selenium (Se) nanoparticles for electrical characterization and possible application as micro/nano devices. selenium Se nanoparticles were successfully synthesized using a reverse-microemulsion process and investigated structurally using X-ray diffraction and transmission electron microscope. Interdigitated castellated ITO and non-castellated platinum electrodes were employed for manipulation of suspended materials in the fluid. Using ITO electrodes at low frequency limits resulted in deposition of Se particles on electrode surface. When Se particles exposed to platinum electrodes in the 10 Hz–1 kHz range and V {sub p−p}> 8, AC osmotic fluid flow repulses the particles from electrode edges. However, in 10 kHz–10 MHz range and V {sub p−p}> 5, dielectrophoretic force attracts the particles to electrode edges. As the Se particle concentration increased, the trapped Se particles were aligned along the electric field line and bridged the electrode gap. The device was characterized and can potentially be useful in making micro/nano electronic devices.

  8. Generation and Analysis of Transposon Ac/Ds-Induced Chromosomal Rearrangements in Rice Plants.

    PubMed

    Xuan, Yuan Hu; Peterson, Thomas; Han, Chang-Deok

    2016-01-01

    Closely-located transposable elements (TEs) have been known to induce chromosomal breakage and rearrangements via alternative transposition. To study genome rearrangements in rice, an Ac/Ds system has been employed. This system comprises an immobile Ac element expressed under the control of CaMV 35S promoter, and a modified Ds element. A starter line carried Ac and a single copy of Ds at the OsRLG5 (Oryza sativa receptor-like gene 5). To enhance the transpositional activity, seed-derived calli were cultured and regenerated into plants. Among 270 lines regenerated from the starter, one line was selected that contained a pair of inversely-oriented Ds elements at the OsRLG5 (Oryza sativa receptor-like gene 5). The selected line was again subjected to tissue culture to obtain a regenerant population. Among 300 regenerated plants, 107 (36 %) contained chromosomal rearrangements including deletions, duplications, and inversions of various sizes. From 34 plants, transposition mechanisms leading to such genomic rearrangements were analyzed. The rearrangements were induced by sister chromatid transposition (SCT), homologous recombination (HR), and single chromatid transposition (SLCT). Among them, 22 events (65 %) were found to be transmitted to the next generation. These results demonstrate a great potential of tissue culture regeneration and the Ac/Ds system in understanding alternative transposition mechanisms and in developing chromosome engineering in plants. PMID:27557685

  9. Combined Operation of AC and DC Distribution System with Distributed Generation Units

    NASA Astrophysics Data System (ADS)

    Noroozian, Reza; Abedi, Mehrdad; Gharehpetian, Gevorg

    2010-07-01

    This paper presents a DC distribution system which has been supplied by external AC systems as well as local DG units in order to demonstrate an overall solution to power quality issue. In this paper, the proposed operation method is demonstrated by simulation of power transfer between external AC systems, DG units, AC and DC loads. The power flow control in DC distribution system has been achieved by network converters and DG converters. Also, the mathematical model of the network, DG and load converters are obtained by using the average technique, which allows converter systems accurately simulated and control strategies for this converters is achieved. A suitable control strategy for network converters has been proposed that involves DC voltage droop regulator and novel instantaneous power regulation scheme. Also, a novel control technique has been proposed for DG converters. In this paper, a novel control system based on stationary and synchronously rotating reference frame has been proposed for load converters for supplying AC loads connected to the DC bus by balanced voltages. The several case studies have been studied based on proposed methods. The simulation results show that DC distribution systems including DG units can improve the power quality at the point of common coupling (PCC) in the power distribution system or industrial power system.

  10. The multiphoton AC Stark effect

    NASA Astrophysics Data System (ADS)

    Rudolph, T. G.; Ficek, Z.; Freedhoff, H. S.

    1998-02-01

    We study the interaction of a two-level atom with two intense lasers: a strong laser of Rabi frequency 2Ω on resonance with the atomic transition, and a weaker laser detuned by 2Ω/n, i.e. by a subharmonic of the Rabi frequency of the first. The second laser "dresses" the dressed states created by the first in an n-photon process. We calculate the energy levels and eigenstates of this "doubly-dressed" atom, and find a new phenomenon: the splitting of the energy levels due to an n-photon coupling between them, resulting in a multiphoton AC Stark effect. We illustrate this effect in the fluorescence spectrum, and show that the spectrum contains triplets at the subharmonic as well as harmonic resonance frequencies with a clear dependence on the order n of the resonance and the ratio α of the Rabi frequencies of the lasers

  11. Protection of superconducting AC windings

    SciTech Connect

    Verhaege, T.; Agnoux, C.; Tavergnier, J.P. ); Lacaze, A. ); Collet, M. )

    1992-01-01

    Recent progresses on multifilamentary wires open new prospects of 50-60 Hz applications for superconductivity. The problem of AC windings protection is more critical than that of DC windings, because of high current densities, and of high matrix resistivity: one should not allow the quenched wire to carry it nominal current for longer than a few milliseconds, otherwise permanent damage could occur. After a quench initiation, the protection system therefore has to switch off or drastically reduce the current very rapidly. In this paper, the authors propose various schemes, applicable when the conductor is made of several wires: active protection involves an ultra-rapid quench detection. It is based on the measurement of the current passing through the central resistive wire, and/or of unbalanced currents in the different superconducting wires. About 20 milliseconds after detection, a fast circuit-breaker switched off the current. A complementary passive protection is provided by the resistance developing during normal phase propagation.

  12. International Space Station Atmosphere Control and Supply, Atmosphere Revitalization, and Water Recovery and Management Subsystem - Verification for Node 1

    NASA Technical Reports Server (NTRS)

    Williams, David E.

    2007-01-01

    The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper provides a summary of the nominal operation of the Node 1 ACS, AR, and WRM design and detailed Element Verification methodologies utilized during the Qualification phase for Node 1.

  13. International Space Station Environmental Control and Life Support System Acceptance Testing for Node 1 Atmosphere Control and Supply Subsystem

    NASA Technical Reports Server (NTRS)

    Williams, David E.

    2009-01-01

    The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper provides a summary of the Node 1 ECLS ACS subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for that subsystem.

  14. Power-Supply-Conditioning Circuit

    NASA Technical Reports Server (NTRS)

    Primas, L. E.; Loveland, R. C.

    1989-01-01

    Fluctuations of voltage suppressed in power supplies for precise radio-frequency circuits. Circuit suppresses both periodic and random deviations of dc supply voltage from desired steady level. Highly-stable feedback voltage regulator, conditioner intended in conjunction with conventional power-supply circuit to provide constant voltage to atomic frequency standard or other precise oscillator. Without conditioners, outputs of most commercial power supplies contain fluctuations causing unacceptably-large phase and amplitude modulation of precise oscillators.

  15. Food and water supply

    NASA Technical Reports Server (NTRS)

    Popov, I. G.

    1975-01-01

    Supplying astronauts with adequate food and water on short and long-term space flights is discussed based on experiences gained in space flight. Food consumption, energy requirements, and suitability of the foodstuffs for space flight are among the factors considered. Physicochemical and biological methods of food production and regeneration of water from astronaut metabolic wastes, as well as wastes produced in a closed ecological system, or as a result of technical processes taking place in various spacecraft systems are suggested for long-term space flights.

  16. Expression of MUC5AC and MUC5B mucins in normal and cystic fibrosis lung.

    PubMed

    Groneberg, D A; Eynott, P R; Oates, T; Lim, S; Wu, R; Carlstedt, I; Nicholson, A G; Chung, K F

    2002-02-01

    Hypersecretion of airway mucus is a characteristic feature of chronic airway diseases like cystic fibrosis (CF) and leads via impairment of the muco-ciliary clearance and bacterial superinfection to respiratory failure. The major components of the mucus matrix forming family of mucins in the airways are MUC5AC and MUC5B. To investigate the expression of these glycoproteins in CF, immunohistochemistry was carried out on trachea, bronchi and peripheral lung obtained from CF patients and compared to normal lung tissues. MUC5AC immunohistochemistry demonstrated signals in goblet cells of the epithelial lining. Also, goblet cells inside glandular secretory ducts revealed MUC5AC-positive staining. In comparison to those from normal subjects, CF sections were characterized by inflammatory changes and goblet cell hyperplasia, resulting in increased numbers of MUC5AC-positive cells. Immunohistochemical staining for MUC5B showed abundant staining of submucosal glands and epithelial goblet cells. Inside the glands, the immunoreactivity was restricted to glandular mucous cells. MUC5AC and MUC5B are expressed in the same histological pattern in CF compared to normal tissues with an increase of MUC5AC-positive cells due to goblet cell hyper- and metaplasia. PMID:11860173

  17. Therapeutic potential of an AcHERV-HPV L1 DNA vaccine.

    PubMed

    Lee, Hee-Jung; Yoon, Jong Kwang; Heo, Yoonki; Cho, Hansam; Cho, Yeondong; Gwon, Yongdae; Kim, Kang Chang; Choi, Jiwon; Lee, Jae Sung; Oh, Yu-Kyoung; Kim, Young Bong

    2015-06-01

    Cervical cancer is strongly associated with chronic human papillomavirus infections, among which HPV16 is the most common. Two commercial HPV vaccines, Gardasil and Cervarix are effective for preventing HPV infection, but cannot be used to treat existing HPV infections. Previously, we developed a human endogenous retrovirus (HERV)-enveloped recombinant baculovirus capable of delivering the L1 genes of HPV types 16, 18, and 58 (AcHERV-HP16/18/58L1, AcHERV-HPV). Intramuscular administration of AcHERVHPV vaccines induced a strong cellular immune response as well as a humoral immune response. In this study, to examine the therapeutic effect of AcHERV-HPV in a mouse model, we established an HPV16 L1 expressing tumor cell line. Compared to Cervarix, immunization with AcHERVHPV greatly enhanced HPV16 L1-specific cytotoxic T lymphocytes (CTL) in C57BL/6 mice. Although vaccination could not remove preexisting tumors, strong CTL activity retarded the growth of inoculated tumor cells. These results indicate that AcHERV-HPV could serve as a potential therapeutic DNA vaccine against concurrent infection with HPV 16, 18, and 58. PMID:26025174

  18. Methods, systems and apparatus for controlling operation of two alternating current (AC) machines

    DOEpatents

    Gallegos-Lopez, Gabriel; Nagashima, James M.; Perisic, Milun; Hiti, Silva

    2012-02-14

    A system is provided for controlling two AC machines. The system comprises a DC input voltage source that provides a DC input voltage, a voltage boost command control module (VBCCM), a five-phase PWM inverter module coupled to the two AC machines, and a boost converter coupled to the inverter module and the DC input voltage source. The boost converter is designed to supply a new DC input voltage to the inverter module having a value that is greater than or equal to a value of the DC input voltage. The VBCCM generates a boost command signal (BCS) based on modulation indexes from the two AC machines. The BCS controls the boost converter such that the boost converter generates the new DC input voltage in response to the BCS. When the two AC machines require additional voltage that exceeds the DC input voltage required to meet a combined target mechanical power required by the two AC machines, the BCS controls the boost converter to drive the new DC input voltage generated by the boost converter to a value greater than the DC input voltage.

  19. Protective supplied breathing air garment

    DOEpatents

    Childers, Edward L.; von Hortenau, Erik F.

    1984-07-10

    A breathing air garment for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap.

  20. Protective supplied breathing air garment

    DOEpatents

    Childers, E.L.; Hortenau, E.F. von.

    1984-07-10

    A breathing air garment is disclosed for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap. 17 figs.

  1. Future natural gas supplies

    NASA Astrophysics Data System (ADS)

    Despite recent optimism about the outlook for the future supply of domestic conventional natural gas, the Congressional Office of Technology Assessment (OTA) finds insufficient evidence to clearly justify either an optimistic or a pessimistic view. In a technical memorandum entitled “U.S. Natural Gas Availability: Conventional Gas Supply Through the Year 2000,” released recently by Rep. Philip R. Sharp (D-Ind,), chairman of the Subcommittee on Fossil and Synthetic Fuels of the Committee on Energy and Commerce, OTA concluded that substantial technical uncertainties prevented a reliable estimation of the likely natural gas production rates for later in this century. Even ignoring the potential for significant changes in gas prices and technology, OTA estimated that conventional gas production by the lower 48 states in the year 2000 could range from 9 to 19 trillion cubic feet (TCF) (0.25 to 0.53 trillion cubic meters), compared to 1982 production of 17.5 TCF. Similarly, production in the year 1990 could range from 13 to 20 TCF.

  2. Input-current shaped ac to dc converters

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The problem of achieving near unity power factor while supplying power to a dc load from a single phase ac source of power is examined. Power processors for this application must perform three functions: input current shaping, energy storage, and output voltage regulation. The methods available for performing each of these three functions are reviewed. Input current shaping methods are either active or passive, with the active methods divided into buck-like and boost-like techniques. In addition to large reactances, energy storage methods include resonant filters, active filters, and active storage schemes. Fast voltage regulation can be achieved by post regulation or by supplementing the current shaping topology with an extra switch. Some indications of which methods are best suited for particular applications concludes the discussion.

  3. AC motor controller with 180 degree conductive switches

    NASA Technical Reports Server (NTRS)

    Oximberg, Carol A. (Inventor)

    1995-01-01

    An ac motor controller is operated by a modified time-switching scheme where the switches of the inverter are on for electrical-phase-and-rotation intervals of 180.degree. as opposed to the conventional 120.degree.. The motor is provided with three-phase drive windings, a power inverter for power supplied from a dc power source consisting of six switches, and a motor controller which controls the current controlled switches in voltage-fed mode. During full power, each switch is gated continuously for three successive intervals of 60.degree. and modulated for only one of said intervals. Thus, during each 60.degree. interval, the two switches with like signs are on continuously and the switch with the opposite sign is modulated.

  4. Resistojet control and power for high frequency ac buses

    NASA Technical Reports Server (NTRS)

    Gruber, Robert P.

    1987-01-01

    Resistojets are operational on many geosynchronous communication satellites which all use dc power buses. Multipropellant resistojets were selected for the Initial Operating Capability (IOC) Space Station which will supply 208 V, 20 kHz power. This paper discusses resistojet heater temperature controllers and passive power regulation methods for ac power systems. A simple passive power regulation method suitable for use with regulated sinusoidal or square wave power was designed and tested using the Space Station multipropellant resistojet. The breadboard delivered 20 kHz power to the resistojet heater. Cold start surge current limiting, a power efficiency of 95 percent, and power regulation of better than 2 percent were demonstrated with a two component, 500 W breadboard power controller having a mass of 0.6 kg.

  5. Resistojet control and power for high frequency ac buses

    NASA Astrophysics Data System (ADS)

    Gruber, Robert P.

    Resistojets are operational on many geosynchronous communication satellites which all use dc power buses. Multipropellant resistojets were selected for the Initial Operating Capability (IOC) Space Station which will supply 208 V, 20 kHz power. This paper discusses resistojet heater temperature controllers and passive power regulation methods for ac power systems. A simple passive power regulation method suitable for use with regulated sinusoidal or square wave power was designed and tested using the Space Station multipropellant resistojet. The breadboard delivered 20 kHz power to the resistojet heater. Cold start surge current limiting, a power efficiency of 95 percent, and power regulation of better than 2 percent were demonstrated with a two component, 500 W breadboard power controller having a mass of 0.6 kg.

  6. Resistojet control and power for high frequency ac buses

    NASA Astrophysics Data System (ADS)

    Gruber, Robert P.

    1987-05-01

    Resistojets are operational on many geosynchronous communication satellites which all use dc power buses. Multipropellant resistojets were selected for the Initial Operating Capability (IOC) Space Station which will supply 208 V, 20 kHz power. This paper discusses resistojet heater temperature controllers and passive power regulation methods for ac power systems. A simple passive power regulation method suitable for use with regulated sinusoidal or square wave power was designed and tested using the Space Station multipropellant resistojet. The breadboard delivered 20 kHz power to the resistojet heater. Cold start surge current limiting, a power efficiency of 95 percent, and power regulation of better than 2 percent were demonstrated with a two component, 500 W breadboard power controller having a mass of 0.6 kg.

  7. Early detection of colonic dysplasia by magnetic resonance molecular imaging with a contrast agent raised against the colon cancer marker MUC5AC.

    PubMed

    Rossez, Yannick; Burtea, Carmen; Laurent, Sophie; Gosset, Pierre; Léonard, Renaud; Gonzalez, Walter; Ballet, Sébastien; Raynal, Isabelle; Rousseaux, Olivier; Dugué, Timothée; Vander Elst, Luce; Michalski, Jean-Claude; Muller, Robert N; Robbe-Masselot, Catherine

    2016-05-01

    Human gastric mucin MUC5AC is secreted in the colonic mucus of cancer patients and is a specific marker of precancerous lesions called aberrant crypt foci. Using MUC5AC as a specific marker can improve sensitivity in the detection of early colorectal cancer. Here we demonstrated that the accumulation of MUC5AC in xenograft and mouse stomach can be detected by magnetic resonance imaging (MRI). We used ultrasmall particles of iron oxide (USPIOs) conjugated with disulfide constrained heptapeptide that were identified using a screening phage display. To accomplish this, we employed positive selection of the phage display library on MUC5AC purified from fresh human colonic adenomas in combination with negative selection of the phage library on purified human MUC2, which is predominantly found in normal colorectal tissues. This conjugate was tested on human colorectal cancer cell lines that were either able or unable to secrete MUC5AC, both in vitro and in vivo. MUC5AC-USPIO contrast agent and USPIOs alone were not detected in cell lines unable to secrete MUC5AC. A combination of MRI and microscopy studies was performed to detect a specific accumulation of the contrast agent in vivo. Thus, the MUC5AC contrast agent enabled non-invasive detection of precancerous lesions and colorectal cancer, highlighting its potential use in diagnostics, in the early detection of colorectal cancer recurrences after treatment and in mechanistic studies implicating MUC5AC. Copyright © 2016 John Wiley & Sons, Ltd. PMID:26762591

  8. A 65-kV insulated gate bipolar transistor switch applied in damped AC voltages partial discharge detection system.

    PubMed

    Jiang, J; Ma, G M; Luo, D P; Li, C R; Li, Q M; Wang, W

    2014-02-01

    Damped AC voltages detection system (DAC) is a productive way to detect the faults in power cables. To solve the problems of large volume, complicated structure and electromagnetic interference in existing switches, this paper developed a compact solid state switch based on electromagnetic trigger, which is suitable for DAC test system. Synchronous electromagnetic trigger of 32 Insulated Gate Bipolar Transistors (IGBTs) in series was realized by the topological structure of single line based on pulse width modulation control technology. In this way, external extension was easily achieved. Electromagnetic trigger and resistor-capacitor-diode snubber circuit were optimized to reduce the switch turn-on time and circular layout. Epoxy encapsulating was chosen to enhance the level of partial discharge initial voltage (PDIV). The combination of synchronous trigger and power supply is proposed to reduce the switch volume. Moreover, we have overcome the drawback of the electromagnetic interference and improved the detection sensitivity of DAC by using capacitor storage energy to maintain IGBT gate driving voltage. The experimental results demonstrated that the solid-state switch, with compact size, whose turn-on time was less than 400 ns and PDIV was more than 65 kV, was able to meet the actual demands of 35 kV DAC test system. PMID:24593382

  9. A 65-kV insulated gate bipolar transistor switch applied in damped AC voltages partial discharge detection system

    NASA Astrophysics Data System (ADS)

    Jiang, J.; Ma, G. M.; Luo, D. P.; Li, C. R.; Li, Q. M.; Wang, W.

    2014-02-01

    Damped AC voltages detection system (DAC) is a productive way to detect the faults in power cables. To solve the problems of large volume, complicated structure and electromagnetic interference in existing switches, this paper developed a compact solid state switch based on electromagnetic trigger, which is suitable for DAC test system. Synchronous electromagnetic trigger of 32 Insulated Gate Bipolar Transistors (IGBTs) in series was realized by the topological structure of single line based on pulse width modulation control technology. In this way, external extension was easily achieved. Electromagnetic trigger and resistor-capacitor-diode snubber circuit were optimized to reduce the switch turn-on time and circular layout. Epoxy encapsulating was chosen to enhance the level of partial discharge initial voltage (PDIV). The combination of synchronous trigger and power supply is proposed to reduce the switch volume. Moreover, we have overcome the drawback of the electromagnetic interference and improved the detection sensitivity of DAC by using capacitor storage energy to maintain IGBT gate driving voltage. The experimental results demonstrated that the solid-state switch, with compact size, whose turn-on time was less than 400 ns and PDIV was more than 65 kV, was able to meet the actual demands of 35 kV DAC test system.

  10. Input current shaped ac-to-dc converters

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Input current shaping techniques for ac-to-dc converters were investigated. Input frequencies much higher than normal, up to 20 kHz were emphasized. Several methods of shaping the input current waveform in ac-to-dc converters were reviewed. The simplest method is the LC filter following the rectifier. The next simplest method is the resistor emulation approach in which the inductor size is determined by the converter switching frequency and not by the line input frequency. Other methods require complicated switch drive algorithms to construct the input current waveshape. For a high-frequency line input, on the order of 20 kHz, the simple LC cannot be discarded so peremptorily, since the inductor size can be compared with that for the resistor emulation method. In fact, since a dc regulator will normally be required after the filter anyway, the total component count is almost the same as for the resistor emulation method, in which the filter is effectively incorporated into the regulator.

  11. Energy supply interruptions and national security.

    PubMed

    Alm, A L

    1981-03-27

    Vulnerability to oil supply interruptions poses serious threats to the U.S. economy and the life-style of its citizens. The Iranian cutbacks in 1979 resulted in price increases of 120 percent in 1 year and gasoline lines across the country. Creation and use of ample public and private stocks could moderate price increases after another interruption and prevent disruption of supplies. Use of the marketplace to allocate shortages, coupled with rebates to cushion blows to the economy and hardship to individuals, would be eminently more efficient than government allocation programs. International cooperation, through coordination of stock buildup and withdrawal, could mitigate the damage from oil disruptions among all the Western nations. PMID:17731165

  12. Superconductor coil geometry and ac losses

    NASA Technical Reports Server (NTRS)

    Pierce, T. V., Jr.; Zapata, R. N.

    1976-01-01

    An empirical relation is presented which allows simple computation of volume-averaged winding fields from central fields for coils of small rectangular cross sections. This relation suggests that, in certain applications, ac-loss minimization can be accomplished by use of low winding densities, provided that hysteresis losses are independent of winding density. The ac-loss measurements on coils wound of twisted multifilamentary composite superconductors show no significant dependence on ac losses on winding density, thus permitting the use of winding density as an independent design parameter in loss minimization.

  13. Three phase AC motor controller

    DOEpatents

    Vuckovich, Michael; Wright, Maynard K.; Burkett, John P.

    1984-03-20

    A motor controller for a three phase AC motor (10) which is adapted to operate bidirectionally from signals received either from a computer (30) or a manual control (32). The controller is comprised of digital logic circuit means which implement a forward and reverse command signal channel (27, 29) for the application of power through the forward and reverse power switching relays (16, 18, 20, 22). The digital logic elements are cross coupled to prevent activation of both channels simultaneously and each includes a plugging circuit (65, 67) for stopping the motor upon the removal of control signal applied to one of the two channels (27, 29) for a direction of rotation desired. Each plugging circuit (65, 67) includes a one-shot pulse signal generator (88, 102) which outputs a single pulse signal of predetermined pulsewidth which is adapted to inhibit further operation of the application of power in the channel which is being activated and to apply a reversal command signal to the other channel which provides a reversed phase application of power to the motor for a period defined by the pulse-width output of the one-shot signal generator to plug the motor (10) which will then be inoperative until another rotational command signal is applied to either of the two channels.

  14. Static state estimation of multiterminal DC/AC power system in rectangular co-ordinates

    SciTech Connect

    Roy, L.; Sinha, A.K. ); Srivastava, H.N.P. )

    1991-01-01

    This paper describes a simple, efficient and reliable method for estimating the state of an integrated multiterminal HVDC/AC power system in the rectangular coordinate form. A six variable model is used to represent the converter system. The proposed algorithm performs successfully in obtaining the state of an AC system with a DC link or a multiterminal DC network. It is possible to implement it for an on-line state estimation. Simulation results of a 30-busbar system are presented for illustration.

  15. A Generalised Fault Protection Structure Proposed for Uni-grounded Low-Voltage AC Microgrids

    NASA Astrophysics Data System (ADS)

    Bui, Duong Minh; Chen, Shi-Lin; Lien, Keng-Yu; Jiang, Jheng-Lun

    2016-04-01

    This paper presents three main configurations of uni-grounded low-voltage AC microgrids. Transient situations of a uni-grounded low-voltage (LV) AC microgrid (MG) are simulated through various fault tests and operation transition tests between grid-connected and islanded modes. Based on transient simulation results, available fault protection methods are proposed for main and back-up protection of a uni-grounded AC microgrid. In addition, concept of a generalised fault protection structure of uni-grounded LVAC MGs is mentioned in the paper. As a result, main contributions of the paper are: (i) definition of different uni-grounded LVAC MG configurations; (ii) analysing transient responses of a uni-grounded LVAC microgrid through line-to-line faults, line-to-ground faults, three-phase faults and a microgrid operation transition test, (iii) proposing available fault protection methods for uni-grounded microgrids, such as: non-directional or directional overcurrent protection, under/over voltage protection, differential current protection, voltage-restrained overcurrent protection, and other fault protection principles not based on phase currents and voltages (e.g. total harmonic distortion detection of currents and voltages, using sequence components of current and voltage, 3I0 or 3V0 components), and (iv) developing a generalised fault protection structure with six individual protection zones to be suitable for different uni-grounded AC MG configurations.

  16. NNSA TRITIUM SUPPLY CHAIN

    SciTech Connect

    Wyrick, Steven; Cordaro, Joseph; Founds, Nanette; Chambellan, Curtis

    2013-08-21

    Savannah River Site plays a critical role in the Tritium Production Supply Chain for the National Nuclear Security Administration (NNSA). The entire process includes: • Production of Tritium Producing Burnable Absorber Rods (TPBARs) at the Westinghouse WesDyne Nuclear Fuels Plant in Columbia, South Carolina • Production of unobligated Low Enriched Uranium (LEU) at the United States Enrichment Corporation (USEC) in Portsmouth, Ohio • Irradiation of TPBARs with the LEU at the Tennessee Valley Authority (TVA) Watts Bar Reactor • Extraction of tritium from the irradiated TPBARs at the Tritium Extraction Facility (TEF) at Savannah River Site • Processing the tritium at the Savannah River Site, which includes removal of nonhydrogen species and separation of the hydrogen isotopes of protium, deuterium and tritium.

  17. Switching power supply

    DOEpatents

    Mihalka, A.M.

    1984-06-05

    The invention is a repratable capacitor charging, switching power supply. A ferrite transformer steps up a dc input. The transformer primary is in a full bridge configuration utilizing power MOSFETs as the bridge switches. The transformer secondary is fed into a high voltage, full wave rectifier whose output is connected directly to the energy storage capacitor. The transformer is designed to provide adequate leakage inductance to limit capacitor current. The MOSFETs are switched to the variable frequency from 20 to 50 kHz to charge a capacitor from 0.6 kV. The peak current in a transformer primary and secondary is controlled by increasing the pulse width as the capacitor charges. A digital ripple counter counts pulses and after a preselected desired number is reached an up-counter is clocked.

  18. Sustainable Biomass Supply Systems

    SciTech Connect

    Erin Searcy; Dave Muth; Erin Wilkerson; Shahab Sokansanj; Bryan Jenkins; Peter Titman; Nathan Parker; Quinn Hart; Richard Nelson

    2009-04-01

    The U.S. Department of Energy (DOE) aims to displace 30% of the 2004 gasoline use (60 billion gal/yr) with biofuels by 2030 as outlined in the Energy Independence and Security Act of 2007, which will require 700 million tons of biomass to be sustainably delivered to biorefineries annually. Lignocellulosic biomass will make an important contribution towards meeting DOE’s ethanol production goals. For the biofuels industry to be an economically viable enterprise, the feedstock supply system (i.e., moving the biomass from the field to the refinery) cannot contribute more that 30% of the total cost of the biofuel production. The Idaho National Laboratory in collaboration with Oak Ridge National Laboratory, University of California, Davis and Kansas State University are developing a set of tools for identifying economical, sustainable feedstocks on a regional basis based on biorefinery siting.

  19. Engineering cotton (Gossypium hirsutum L.) for resistance to cotton leaf curl disease using viral truncated AC1 DNA sequences.

    PubMed

    Hashmi, Jamil A; Zafar, Yusuf; Arshad, Muhammad; Mansoor, Shahid; Asad, Shaheen

    2011-04-01

    Several important biological processes are performed by distinct functional domains found on replication-associated protein (Rep) encoded by AC1 of geminiviruses. Two truncated forms of replicase (tAC1) gene, capable of expressing only the N-terminal 669 bp (5'AC1) and C-terminal 783 bp (3'AC1) nucleotides cloned under transcriptional control of the CaMV35S were introduced into cotton (Gossypium hirsutum L.) using LBA4404 strain of Agrobacterium tumefaciens to make use of an interference strategy for impairing cotton leaf curl virus (CLCuV) infection in transgenic cotton. Compared with nontransformed control, we observed that transgenic cotton plants overexpressing either N-terminal (5'AC1) or C-terminal (3'AC1) sequences confer resistance to CLCuV by inhibiting replication of viral genomic and β satellite DNA components. Molecular analysis by Northern blot hybridization revealed high transgene expression in early and late growth stages associated with inhibition of CLCuV replication. Of the eight T(1) transgenic lines tested, six had delayed and minor symptoms as compared to nontransformed control lines which developed disease symptoms after 2-3 weeks of whitefly-mediated viral delivery. Virus biological assay and growth of T(2) plants proved that transgenic cotton plants overexpressing 5'- and 3'AC1 displayed high resistance level up to 72, 81%, respectively, as compared to non-transformed control plants following inoculation with viruliferous whiteflies giving significantly high cotton seed yield. Progeny analysis of these plants by polymerase chain reaction (PCR), Southern blotting and virus biological assay showed stable transgene, integration, inheritance and cotton leaf curl disease (CLCuD) resistance in two of the eight transgenic lines having single or two transgene insertions. Transgenic cotton expressing partial AC1 gene of CLCuV can be used as virus resistance source in cotton breeding programs aiming to improve virus resistance in cotton crop. PMID

  20. Tevatron optics measurements using an AC dipole

    SciTech Connect

    Miyamoto, R.; Kopp, S.E.; Jansson, A.; Syphers, M.J.; /Fermilab

    2007-06-01

    The AC dipole is a device to study beam optics of hadron synchrotrons. It can produce sustained large amplitude oscillations with virtually no emittance growth. A vertical AC dipole for the Tevatron is recently implemented and a maximum oscillation amplitude of 2{sigma} (4{sigma}) at 980 GeV (150 GeV) is achieved [1]. When such large oscillations are measured with the BPM system of the Tevatron (20 {micro}m resolution), not only linear but even nonlinear optics can be directly measured. This paper shows how to measure {beta} function using an AC dipole and the result is compared to the other measurement. The paper also shows a test to detect optics changes when small changes are made in the Tevatron. Since an AC dipole is nondestructive, it allows frequent measurements of the optics which is necessary for such an test.

  1. The AC-120: The advanced commercial transport

    NASA Technical Reports Server (NTRS)

    Duran, David; Griffin, Ernest; Mendoza, Saul; Nguyen, Son; Pickett, Tim; Noernberg, Clemm

    1993-01-01

    The main objective of this design was to fulfill a need for a new airplane to replace the aging 100 to 150 passenger, 1500 nautical mile range aircraft such as the Douglas DC9 and Boeing 737-100 airplanes. After researching the future aircraft market, conducting extensive trade studies, and analysis on different configurations, the AC-120 Advanced Commercial Transport final design was achieved. The AC-120's main design features include the incorporation of a three lifting surface configuration which is powered by two turboprop engines. The AC-120 is an economically sensitive aircraft which meets the new FM Stage Three noise requirements, and has lower NO(x) emissions than current turbofan powered airplanes. The AC-120 also improves on its contemporaries in passenger comfort, manufacturing, and operating cost.

  2. New ACS Guidelines Approved by CPT

    NASA Astrophysics Data System (ADS)

    Polik, William F.; Larive, Cynthia K.

    2008-04-01

    The American Chemical Society (ACS) Guidelines for Bachelor's Degree Programs have been revised in 2008 by the Committee on Professional Training (CPT) to reflect changes that are occurring in the chemistry profession and chemistry education. The goals of these changes are to promote modern and innovative chemistry curricula, encourage pedagogical innovation that enhances student learning and success, define faculty and infrastructure attributes of excellent chemistry programs, and streamline the procedures for program approval and review by ACS. The curriculum guidelines for an ACS-certified bachelor's degree are described in terms of foundation coursework, in-depth coursework, and laboratory requirements. Chemistry departments are encouraged to develop degree tracks to target emerging areas of interest within chemistry. The importance of developing student skills and regular program self-evaluation is emphasized. Finally, the procedures for approving and reviewing chemistry programs by ACS are summarized.

  3. Line-by-line spectroscopic simulations on graphics processing units

    NASA Astrophysics Data System (ADS)

    Collange, Sylvain; Daumas, Marc; Defour, David

    2008-01-01

    We report here on software that performs line-by-line spectroscopic simulations on gases. Elaborate models (such as narrow band and correlated-K) are accurate and efficient for bands where various components are not simultaneously and significantly active. Line-by-line is probably the most accurate model in the infrared for blends of gases that contain high proportions of H 2O and CO 2 as this was the case for our prototype simulation. Our implementation on graphics processing units sustains a speedup close to 330 on computation-intensive tasks and 12 on memory intensive tasks compared to implementations on one core of high-end processors. This speedup is due to data parallelism, efficient memory access for specific patterns and some dedicated hardware operators only available in graphics processing units. It is obtained leaving most of processor resources available and it would scale linearly with the number of graphics processing units in parallel machines. Line-by-line simulation coupled with simulation of fluid dynamics was long believed to be economically intractable but our work shows that it could be done with some affordable additional resources compared to what is necessary to perform simulations on fluid dynamics alone. Program summaryProgram title: GPU4RE Catalogue identifier: ADZY_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADZY_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 62 776 No. of bytes in distributed program, including test data, etc.: 1 513 247 Distribution format: tar.gz Programming language: C++ Computer: x86 PC Operating system: Linux, Microsoft Windows. Compilation requires either gcc/g++ under Linux or Visual C++ 2003/2005 and Cygwin under Windows. It has been tested using gcc 4.1.2 under Ubuntu Linux 7.04 and using Visual C

  4. Semipermissive replication of a nuclear polyhedrosis virus of Autographa californica in a gypsy moth cell line

    SciTech Connect

    McClintock, J.T.; Dougherty, E.M.; Weiner, R.M.

    1986-01-01

    Several gypsy moth cell lines have been previously described as nonpermissive for the multiple-embedded nuclear polyhedrosis virus of Autographa californica (AcMNPV). In this report, the authors demonstrate the semipermissive infection of a gypsy moth cell line, IPLB-LD-652Y, with AcMNPV. IPLB-LD-652Y cells infected with AcMNPV produced classic cytopathic effects but failed to yield infectious progeny virus. Results of experiments employing DNA-DNA dot hybridization suggested that AcMNPV DNA synthesis was initiated from 8 to 12 h postinfection (p.i.), continued at a maximum rate from 12 to 20 h p.i., and declined from 20 to 36 h p.i. The rate of AcMNPV DNA synthesis approximated that observed in the permissive TN-368 cell line. AcMNPV-infected IPLB-LD-652Y cells, pulse-labeled with (/sup 35/S)methionine at various time intervals p.i. and analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, revealed four virus-induced proteins, one novel to the semipermissive system and three early ..cap alpha.. proteins, synthesized from 1 to 20 h p.i. Thereafter, both host and viral protein synthesis was completely suppressed. These results suggest that AcMNPV adsorbed, penetrated, and initiated limited macromolecular synthesis in the semipermissive gypsy moth cell line. However, the infection cycle was restricted during the early phase of AcMNPV replication.

  5. Optics Supply Planning System

    SciTech Connect

    Gaylord, J

    2009-04-30

    The purpose of this study is to specify the design for an initial optics supply planning system for NIF, and to present quality assurance and test plans for the construction of the system as specified. The National Ignition Facility (NIF) is a large laser facility that is just starting operations. Thousands of specialized optics are required to operate the laser, and must be exchanged over time based on the laser shot plan and predictions of damage. Careful planning and tracking of optic exchanges is necessary because of the tight inventory of spare optics, and the long lead times for optics procurements and production changes. Automated inventory forecasting and production planning tools are required to replace existing manual processes. The optics groups members who are expected to use the supply planning system are the stakeholders for this project, and are divided into three groups. Each of these groups participated in a requirements specification that was used to develop this design. (1) Optics Management--These are the top level stakeholdersk, and the final decision makers. This group is the interface to shot operations, is ultimately responsible for optics supply, and decides which exchanges will be made. (2) Work Center Managers--This group manages the on site optics processing work centers. They schedule the daily work center operations, and are responsible for developing long term processing, equipment, and staffing plans. (3) Component Engineers--This group manages the vendor contracts for the manufacture of new optics and the off site rework of existing optics. They are responsible for sourcing vendors, negotiating contracts, and managing vendor processes. The scope of this analysis is to describe the structure and design details of a system that will meet all requirements that were described by stakeholders and documented in the analysis model for this project. The design specifies the architecture, components, interfaces, and data stores of the system

  6. Developing sustainable food supply chains.

    PubMed

    Smith, B Gail

    2008-02-27

    This paper reviews the opportunities available for food businesses to encourage consumers to eat healthier and more nutritious diets, to invest in more sustainable manufacturing and distribution systems and to develop procurement systems based on more sustainable forms of agriculture. The important factors in developing more sustainable supply chains are identified as the type of supply chain involved and the individual business attitude to extending responsibility for product quality into social and environmental performance within their own supply chains. Interpersonal trust and working to standards are both important to build more sustainable local and many conserved food supply chains, but inadequate to transform mainstream agriculture and raw material supplies to the manufactured and commodity food markets. Cooperation among food manufacturers, retailers, NGOs, governmental and farmers' organizations is vital in order to raise standards for some supply chains and to enable farmers to adopt more sustainable agricultural practices. PMID:17766237

  7. Molecular and functional characterization of CpACS27A gene reveals its involvement in monoecy instability and other associated traits in squash (Cucurbita pepo L.).

    PubMed

    Martínez, Cecilia; Manzano, Susana; Megías, Zoraida; Barrera, Alejandro; Boualem, Adnane; Garrido, Dolores; Bendahmane, Abdelhafid; Jamilena, Manuel

    2014-06-01

    A number of Cucurbita pepo genotypes showing instable monoecy or partial andromonoecy, i.e. an incomplete conversion of female into bisexual flowers, have been detected. Given that in melon and cucumber andromonoecy is the result of reduction of ethylene production in female floral buds, caused by mutations in the ethylene biosynthesis genes CmACS7 and CsACS2; we have cloned and characterized two related C. pepo genes, CpACS27A and CpACS27B. The molecular structure of CpACS27A and its specific expression in the carpels of female flowers during earlier stages of flower development suggests that this gene is the Cucurbita ortholog of CmACS7 and CsACS2. CpACS27B is likely to be a paralogous pseudogene since it has not been found to be expressed in any of the analyzed tissues. CpACS27A was sequenced in Bolognese (Bog) and Vegetable Spaghetti (Veg), two monoecious inbred lines whose F2 was segregating for partial andromonoecy. The Bog allele of CpACS27A carried a missense mutation that resulted in a substitution of the conserved serine residue in position 176 by an alanine. Segregation analysis indicated that this mutant variant is necessary but not sufficient to confer the andromonoecious phenotype in squash. In concordance with its involvement in stamen arrest, a reduction in CpACS27A expression has been found in bisexual flower buds at earlier stages of development. This reduction in CpACS27A expression was concomitant with a downregulation of other ethylene biosynthesis and signaling genes during earlier and later stages of ovary development. The role of CpACS27A is discussed regarding the regulation of ethylene biosynthesis and signaling genes in the control of andromonoecy-associated traits, such as the delayed maturation of corolla and stigma as well as the parthenocarpic development of the fruit. PMID:24595516

  8. Cholangiocytes and blood supply

    PubMed Central

    Gaudio, Eugenio; Franchitto, Antonio; Pannarale, Luigi; Carpino, Guido; Alpini, Gianfranco; Francis, Heather; Glaser, Shannon; Alvaro, Domenico; Onori, Paolo

    2006-01-01

    The microvascular supply of the biliary tree, the peribiliary plexus (PBP), stems from the hepatic artery branches and flows into the hepatic sinusoids. A detailed three-dimensional study of the PBP has been performed by using the Scanning Electron Microscopy vascular corrosion casts (SEMvcc) technique. Considering that the PBP plays a fundamental role in supporting the secretory and absorptive functions of the biliary epithelium, their organization in either normalcy and pathology is explored. The normal liver shows the PBP arranged around extra- and intrahepatic biliary tree. In the small portal tract PBP was characterized by a single layer of capillaries which progressively continued with the extrahepatic PBP where it showed a more complex vascular network. After common duct ligation (BDL), progressive modifications of bile duct and PBP proliferation are observed. The PBP presents a three-dimensional network arranged around many bile ducts and appears as bundles of vessels, composed by capillaries of homogeneous diameter with a typical round mesh structure. The PBP network is easily distinguishable from the sinusoidal network which appears normal. Considering the enormous extension of the PBP during BDL, the possible role played by the Vascular Endothelial Growth Factor (VEGF) is evaluated. VEGF-A, VEGF-C and their related receptors appeared highly immunopositive in proliferating cholangiocytes of BDL rats. The administration of anti-VEGF-A or anti-VEGF-C antibodies to BDL rats as well as hepatic artery ligation induced a reduced bile duct mass. The administration of rVEGF-A to BDL hepatic artery ligated rats prevented the decrease of cholangiocyte proliferation and VEGF-A expression as compared to BDL control rats. These data suggest the role of arterial blood supply of the biliary tree in conditions of cholangiocyte proliferation, such as it occurs during chronic cholestasis. On the other hand, the role played by VEGF as a tool of cross-talk between

  9. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  10. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  11. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  12. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  13. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  14. Supply Chain Coordination in Hospitals

    NASA Astrophysics Data System (ADS)

    Rego, Nazaré; de Sousa, Jorge Pinho

    This paper presents an innovative approach to support the definition of strategies for the design of alternative configurations of hospital supply chains. This approach was developed around a hybrid Tabu Search / Variable Neighbourhood Search metaheuristic, that uses several neighbourhood structures. The flexibility of the procedure allows its application to supply chains with different topologies and atypical cost characteristics. A preliminary computational experience shows the approach potential in solving large scale supply chain configuration problems. The future incorporation of this approach in a broader Decision Support System (DSS) will provide a tool that can significantly contribute to an increase of healthcare supply chains efficiency and encourage the establishment of collaborative partnerships between their members.

  15. Zapping the food supply

    SciTech Connect

    Louria, D.B. )

    1990-09-01

    The idea of exposing food to gamma radiation is over 30 years old, and in 1963 the Food and Drug Administration (FDA) began to permit the irradiation of wheat. Over the years, a few more foodstuffs such as spices and tea were added, but in 1984 the FDA started to approve irradiation of a much broader list of products which now includes meat, poultry, and fresh fruits and vegetables. Simultaneously the FDA has increased the levels of radiation that may be used. The FDA's recent willingness to allow most of the food supply to be irradiated - and at high doses - has triggered an acrimonious debate. The amount of radiation involved is substantial, with intensities millions of times greater than that of an ordinary chest X-ray. The announced goal of promoters of food irradiation is to obtain general approval for the use of up to one million rad. Irradiation does not make food radioactive, nor has alleged radioactivity been at issue in the debate. But there is concern that foods processed by irradiation may contain radiolytic products that could have toxic effects. 12 refs.

  16. A Power-Efficient Wireless System With Adaptive Supply Control for Deep Brain Stimulation.

    PubMed

    Lee, Hyung-Min; Park, Hangue; Ghovanloo, Maysam

    2013-09-01

    A power-efficient wireless stimulating system for a head-mounted deep brain stimulator (DBS) is presented. A new adaptive rectifier generates a variable DC supply voltage from a constant AC power carrier utilizing phase control feedback, while achieving high AC-DC power conversion efficiency (PCE) through active synchronous switching. A current-controlled stimulator adopts closed-loop supply control to automatically adjust the stimulation compliance voltage by detecting stimulation site potentials through a voltage readout channel, and improve the stimulation efficiency. The stimulator also utilizes closed-loop active charge balancing to maintain the residual charge at each site within a safe limit, while receiving the stimulation parameters wirelessly from the amplitude-shift-keyed power carrier. A 4-ch wireless stimulating system prototype was fabricated in a 0.5-μm 3M2P standard CMOS process, occupying 2.25 mm². With 5 V peak AC input at 2 MHz, the adaptive rectifier provides an adjustable DC output between 2.5 V and 4.6 V at 2.8 mA loading, resulting in measured PCE of 72 ~ 87%. The adaptive supply control increases the stimulation efficiency up to 30% higher than a fixed supply voltage to 58 ~ 68%. The prototype wireless stimulating system was verified in vitro. PMID:24678126

  17. A Power-Efficient Wireless System With Adaptive Supply Control for Deep Brain Stimulation

    PubMed Central

    Lee, Hyung-Min; Park, Hangue; Ghovanloo, Maysam

    2014-01-01

    A power-efficient wireless stimulating system for a head-mounted deep brain stimulator (DBS) is presented. A new adaptive rectifier generates a variable DC supply voltage from a constant AC power carrier utilizing phase control feedback, while achieving high AC-DC power conversion efficiency (PCE) through active synchronous switching. A current-controlled stimulator adopts closed-loop supply control to automatically adjust the stimulation compliance voltage by detecting stimulation site potentials through a voltage readout channel, and improve the stimulation efficiency. The stimulator also utilizes closed-loop active charge balancing to maintain the residual charge at each site within a safe limit, while receiving the stimulation parameters wirelessly from the amplitude-shift-keyed power carrier. A 4-ch wireless stimulating system prototype was fabricated in a 0.5-μm 3M2P standard CMOS process, occupying 2.25 mm². With 5 V peak AC input at 2 MHz, the adaptive rectifier provides an adjustable DC output between 2.5 V and 4.6 V at 2.8 mA loading, resulting in measured PCE of 72 ~ 87%. The adaptive supply control increases the stimulation efficiency up to 30% higher than a fixed supply voltage to 58 ~ 68%. The prototype wireless stimulating system was verified in vitro. PMID:24678126

  18. AC/DC Power Systems with Applications for future Lunar/Mars base and Crew Exploration Vehicle

    NASA Technical Reports Server (NTRS)

    Chowdhury, Badrul H.

    2005-01-01

    ABSTRACT The Power Systems branch at JSC faces a number of complex issues as it readies itself for the President's initiative on future space exploration beyond low earth orbit. Some of these preliminary issues - those dealing with electric power generation and distribution on board Mars-bound vehicle and that on Lunar and Martian surface may be summarized as follows: Type of prime mover - Because solar power may not be readily available on parts of the Lunar/Mars surface and also during the long duration flight to Mars, the primary source of power will most likely be nuclear power (Uranium fuel rods) with a secondary source of fuel cell (Hydrogen supply). The electric power generation source - With nuclear power being the main prime mover, the electric power generation source will most likely be an ac generator at a yet to be determined frequency. Thus, a critical issue is whether the generator should generate at constant or variable frequency. This will decide what type of generator to use - whether it is a synchronous machine, an asynchronous induction machine or a switched reluctance machine. The type of power distribution system - the distribution frequency, number of wires (3- wire, 4-wire or higher), and ac/dc hybridization. Building redundancy and fault tolerance in the generation and distribution sub-systems so that the system is safe; provides 100% availability to critical loads; continues to operate even with faulted sub-systems; and requires minimal maintenance. This report descril_es results of a summer faculty fellowship spent in the Power Systems Branch with the specific aim of investigating some of the lessons learned in electric power generation and usage from the terrestrial power systems industry, the aerospace industry as well as NASA's on-going missions so as to recommend novel surface and vehicle-based power systems architectures in support of future space exploration initiatives. A hybrid ac/dc architecture with source side and load side

  19. Experimental AC (Asphalt Concrete) overlays of PCC pavement

    NASA Astrophysics Data System (ADS)

    Smith, R. D.

    1983-11-01

    A series of experimental asphalt concrete (AC) overlays was constructed over an existing distressed portland cement concrete pavement on Interstate 80 near Boca, California. The experimental overlays included rubberized dense-graded AC, rubberized open-graded AC, a rubber flush coat interlayer, dense-graded AC with short polyester fibers and Bituthene interlayer strips. The report presents a description and discussion of AC mix batching, construction observations, laboratory testing, overlay covering, and initial performance evaluation.

  20. High Voltage Power Supply Design Guide for Space

    NASA Technical Reports Server (NTRS)

    Bever, Renate S.; Ruitberg, Arthur P.; Kellenbenz, Carl W.; Irish, Sandra M.

    2006-01-01

    This book is written for newcomers to the topic of high voltage (HV) in space and is intended to replace an earlier (1970s) out-of-print document. It discusses the designs, problems, and their solutions for HV, mostly direct current, electric power, or bias supplies that are needed for space scientific instruments and devices, including stepping supplies. Output voltages up to 30kV are considered, but only very low output currents, on the order of microamperes. The book gives a brief review of the basic physics of electrical insulation and breakdown problems, especially in gases. It recites details about embedment and coating of the supplies with polymeric resins. Suggestions on HV circuit parts follow. Corona or partial discharge testing on the HV parts and assemblies is discussed both under AC and DC impressed test voltages. Electric field analysis by computer on an HV device is included in considerable detail. Finally, there are many examples given of HV power supplies, complete with some of the circuit diagrams and color photographs of the layouts.

  1. Power supplies and quench protection for the Tokamak Physics Experiment

    SciTech Connect

    Neumeyer, C.L.

    1994-07-01

    The Tokamak Physics Experiment (TPX) is an advanced tokamak project aimed at the production of quasi-steady state plasmas with advanced shape, heating, and particle control. TPX is to be built at the Princeton Plasma Physics Laboratory (PPPL) using many of the facilities from the Tokamak Fusion Test Reactor (TFTR). First plasma is scheduled for the year 2000. TPX will be the first tokamak to utilize superconducting (SC) magnets in both the toroidal field (TF) and poloidal field (PF) systems. This is a new feature which requires not only a departure from the traditional tokamak power supply schemes but also that ultra-reliable quench protection devices be used to rapidly discharge the stored energy from the magnets in the event of a quench. This paper describes the plan and basis for the adaptation and augmentation of the PPPL/TFTR power system facilities to supply TPX. Following a description of the basic operational requirements, four major areas are addressed, namely the AC power system, the TF power supply, the PF power supply, and quench protection for the TF and PF systems.

  2. Approach for Wide Use of Diagnostic Method for XLPE Cables Using Harmonics in AC Loss Current

    NASA Astrophysics Data System (ADS)

    Tsujimoto, Tomiyuki; Nakade, Masahiko; Yagi, Yukihiro; Ishii, Noboru

    Water tree is one of the degradation aspects of XLPE cables used for under-ground distribution or transmission lines. We have developed the loss current method using 3rd harmonic in AC loss current for cable diagnosis. Harmonic components in loss current arise as a result of the non-linear voltage-current characteristics of water trees. We confirmed that the 3rd harmonic in AC loss current had good correlation with water tree growth and break down strength. After that, we have applied this method to the actual 66kV XLPE cable lines. Up to now, the number of the application results is more than 130 lines. In case of cable lines terminated at gas-insulated switchgear (GIS), we have to remove the lightning arrestor (LA) and the potential transformer (PT) out of the test circuit. The reason is that we are afraid that each of LA and PT disturbs the degradation signal from cable lines. It takes extra time (1 or 2 days) and costs more to remove LA and PT in GIS out of a circuit. In order to achieve easy and reasonable diagnosis, we have developed a new method for cable lines terminated at GIS, by utilizing a technique, which enables to reduce signal of LA and PT from disturbed signal of cable lines. We confirmed the effect of the new method by experiments with actual cables.

  3. High performance magnet power supply optimization

    SciTech Connect

    Jackson, L.T.

    1988-01-01

    The power supply system for the joint LBL--SLAC proposed accelerator PEP provides the opportunity to take a fresh look at the current techniques employed for controlling large amounts of dc power and the possibility of using a new one. A basic requirement of +- 100 ppM regulation is placed on the guide field of the bending magnets and quadrupoles placed around the 2200 meter circumference of the accelerator. The optimization questions to be answered by this paper are threefold: Can a firing circuit be designed to reduce the combined effects of the harmonics and line voltage combined effects of the harmonics and line voltage unbalance to less than 100 ppM in the magnet field. Given the ambiguity of the previous statement, is the addition of a transistor bank to a nominal SCR controlled system the way to go or should one opt for an SCR chopper system running at 1 KHz where multiple supplies are fed from one large dc bus and the cost--performance evaluation of the three possible systems.

  4. Repetitive resonant railgun power supply

    DOEpatents

    Honig, E.M.; Nunnally, W.C.

    1985-06-19

    A repetitive resonant railgun power supply provides energy for repetitively propelling projectiles from a pair of parallel rails. The supply comprises an energy storage capacitor, a storage inductor to form a resonant circuit with the energy storage capacitor and a magnetic switch to transfer energy between the resonant circuit and the pair of parallel rails for the propelling of projectiles.

  5. Repetitive resonant railgun power supply

    DOEpatents

    Honig, Emanuel M.; Nunnally, William C.

    1988-01-01

    A repetitive resonant railgun power supply provides energy for repetitively propelling projectiles from a pair of parallel rails. The supply comprises an energy storage capacitor, a storage inductor to form a resonant circuit with the energy storage capacitor and a magnetic switch to transfer energy between the resonant circuit and the pair of parallel rails for the propelling of projectiles.

  6. In-line hydraulic dashpot

    NASA Astrophysics Data System (ADS)

    Moody, Paul E.

    1992-10-01

    An in-line hydraulic dashpot is disclosed that effectively decelerates the piston of a power cylinder by controllably choking off the oil which is providing pressure to the piston. The in-line hydraulic dashpot of the invention includes a valve spool member movable between an open and closed position along a fluid flow path that supplies oil to the power cylinder. An actuator rod is cooperative with the valve spool member and the piston shaft of the power cylinder to move tile valve spool member between its open and closed positions. The in-line hydraulic dashpot eliminates the clashing of mechanical parts and therewith eliminates the noise that would otherwise be generated thereby. The in-line hydraulic dashpot of the present invention makes possible the adaptation of a fixed stroke power cylinder to applications that call for a variable stroke length.

  7. Umbilic Lines in Orientational Order

    NASA Astrophysics Data System (ADS)

    Machon, Thomas; Alexander, Gareth P.

    2016-01-01

    Three-dimensional orientational order in systems whose ground states possess nonzero gradients typically exhibits linelike structures or defects: λ lines in cholesterics or Skyrmion tubes in ferromagnets, for example. Here, we show that such lines can be identified as a set of natural geometric singularities in a unit vector field, the generalization of the umbilic points of a surface. We characterize these lines in terms of the natural vector bundles that the order defines and show that they give a way to localize and identify Skyrmion distortions in chiral materials—in particular, that they supply a natural representative of the Poincaré dual of the cocycle describing the topology. Their global structure leads to the definition of a self-linking number and helicity integral which relates the linking of umbilic lines to the Hopf invariant of the texture.

  8. Intelligent process quality control system into supply chain

    NASA Astrophysics Data System (ADS)

    Wang, Shijie; Jiang, Xingyu; Wang, Yingchun

    2010-01-01

    To cope with the challenges of monitoring dynamic and variable quality variation into supply chain, diagnosing the abnormal variation at the right moment, is a difficult problem that a enterprise in supply chain faces in process quality control. An intelligent process quality control mode into supply chain, which integrated quality prevention, analysis, diagnosis and adjustment, and corresponding functional modules and framework were all put forward. This mode dealt mainly with constructing and running intelligent quality control system, such as the theory of similarity manufacturing, Statistical Process Control (SPC), neural network. Furthermore, some key enabling technologies were studied in detail, including process quality analysis on-line based on similarity process and process quality diagnosis based on Elman and expert system of process quality adjustment. It is basis of realizing network, intelligent and automatic process quality control into supply.

  9. Intelligent process quality control system into supply chain

    NASA Astrophysics Data System (ADS)

    Wang, Shijie; Jiang, Xingyu; Wang, Yingchun

    2009-12-01

    To cope with the challenges of monitoring dynamic and variable quality variation into supply chain, diagnosing the abnormal variation at the right moment, is a difficult problem that a enterprise in supply chain faces in process quality control. An intelligent process quality control mode into supply chain, which integrated quality prevention, analysis, diagnosis and adjustment, and corresponding functional modules and framework were all put forward. This mode dealt mainly with constructing and running intelligent quality control system, such as the theory of similarity manufacturing, Statistical Process Control (SPC), neural network. Furthermore, some key enabling technologies were studied in detail, including process quality analysis on-line based on similarity process and process quality diagnosis based on Elman and expert system of process quality adjustment. It is basis of realizing network, intelligent and automatic process quality control into supply.

  10. Petroleum supply monthly, August 1993

    SciTech Connect

    Not Available

    1993-09-01

    This publication the Petroleum Supply Monthly (PSM) is one of a family of four publications produced by the Petroleum Supply Division within the Energy Information Administration (EIA) reflecting different levels of data timeliness and completeness. The other publications are the Weekly Petroleum Status Report, (WPSR), the Winter Fuels Report, and the Petroleum Supply Annual (PSA). Data presented describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. Data presented are divided into Summary Statistics and Detailed Statistics.

  11. Non-Federal Participation in AC Intertie : Final Environmental Impact Statement. Volume 1: Environmental Analysis.

    SciTech Connect

    United States. Bonneville Power Administration.

    1994-01-01

    Bonneville Power Administration (BPA) is considering action in two areas: (1) non-Federal access to the AC Intertie, and, (2) BPA Intertie marketing. BPA`s preferred alternative for non-Federal access is the Capacity Ownership alternative combined with the Increased Assured Delivery -- Access for Non-Scheduling Utilities alternative; the preferred alternative for BPA Intertie marketing is the Federal Marketing and Joint Ventures alternative. BPA considered these two areas previously in its Intertie Development and Use EIS of April 1988. The EIS resulted in BPA decisions to participate in the construction of the Third AC Intertie, to allow non-Federal access to BPA`s share of the Pacific Northwest-Pacific Southwest (PNW-PSW) Intertie (AC and DC lines) pursuant to a Long-Term Intertie Access Policy (LTIAP), and to pursue BPA`s export marketing alternative. The decision on allowing direct financial non-Federal participation in the Third AC line was deferred to a later, separate process, examined here. Also, BPA`s export marketing objectives must now be examined in view of changed operations of Columbia River hydro facilities for improved fish survival.

  12. Fully digital controlled A.C. servo engraving machine based on DEC4DA

    NASA Astrophysics Data System (ADS)

    Shu, Zhibing; Chen, Xianfeng; Zhang, Hairong; Huang, Yiqun; Yan, Caizhong

    2005-12-01

    A novel engraving machine (NUT-1A) is presented, in which fully digital controlled AC system based on DEC4DA was used to improve the machining precision and sensitivity. This engraving machine was constructed around AC servo motor with encoder, controlled by a servo motor control card - DEC4DA. As the upper unit of AC servo motor, DEC4DA was a numerical control generator, which received pulses form CPU by ISA bus, and these pulses were amplified and converted to drive AC servo actuator. This novel engraving machine can achieve a higher positioning accuracy of +/-0.01mm and positioning repetition of +/-0.005mm, and its resolution is 0.001mm/0.0001mm. Moreover, because of multi-closed loops were used in the system, the steady and transient performances are more excellent. This system ensures a much quicker current regulation in closed-loop operation, of acceleration and braking in both directions, as well as stable speed characteristics. Amplifier boards are protected against excessive current, excessive temperature and short circuiting of the motor supply cables.

  13. Development of software to improve AC power quality on large spacecraft

    NASA Technical Reports Server (NTRS)

    Kraft, L. Alan

    1991-01-01

    To insure the reliability of a 20 kHz, alternating current (AC) power system on spacecraft, it is essential to analyze its behavior under many adverse operating conditions. Some of these conditions include overloads, short circuits, switching surges, and harmonic distortions. Harmonic distortions can become a serious problem. It can cause malfunctions in equipment that the power system is supplying, and, during distortions such as voltage resonance, it can cause equipment and insulation failures due to the extreme peak voltages. To address the harmonic distortion issue, work was begun under the 1990 NASA-ASEE Summer Faculty Fellowship Program. Software, originally developed by EPRI, called HARMFLO, a power flow program capable of analyzing harmonic conditions on three phase, balanced, 60 Hz AC power systems, was modified to analyze single phase, 20 kHz, AC power systems. Since almost all of the equipment used on spacecraft power systems is electrically different from equipment used on terrestrial power systems, it was also necessary to develop mathematical models for the equipment to be used on the spacecraft. The modelling was also started under the same fellowship work period. Details of the modifications and models completed during the 1990 NASA-ASEE Summer Faculty Fellowship Program can be found in a project report. As a continuation of the work to develop a complete package necessary for the full analysis of spacecraft AC power system behavior, deployment work has continued through NASA Grant NAG3-1254. This report details the work covered by the above mentioned grant.

  14. A novel wireless power and data transmission AC to DC converter for an implantable device.

    PubMed

    Liu, Jhao-Yan; Tang, Kea-Tiong

    2013-01-01

    This article presents a novel AC to DC converter implemented by standard CMOS technology, applied for wireless power transmission. This circuit combines the functions of the rectifier and DC to DC converter, rather than using the rectifier to convert AC to DC and then supplying the required voltage with regulator as in the transitional method. This modification can reduce the power consumption and the area of the circuit. This circuit also transfers the loading condition back to the external circuit by the load shift keying(LSK), determining if the input power is not enough or excessive, which increases the efficiency of the total system. The AC to DC converter is fabricated with the TSMC 90nm CMOS process. The circuit area is 0.071mm(2). The circuit can produce a 1V DC voltage with maximum output current of 10mA from an AC input ranging from 1.5V to 2V, at 1MHz to 10MHz. PMID:24110077

  15. Long-range response in ac electricity grids.

    PubMed

    Jung, Daniel; Kettemann, Stefan

    2016-07-01

    Local changes in the topology of electricity grids can cause overloads far away from the disturbance [D. Witthaut and M. Timme, Eur. Phys. J. B 86, 377 (2013)EPJBFY1434-602810.1140/epjb/e2013-40469-4], making the prediction of the robustness against changes in the topology-for example, caused by power outages or grid extensions-a challenging task. The impact of single-line additions on the long-range response of dc electricity grids has recently been studied [D. Labavić, R. Suciu, H. Meyer-Ortmanns, and S. Kettemann, Eur. Phys. J.: Spec. Top. 223, 2517 (2014)1951-635510.1140/epjst/e2014-02273-0]. By solving the real part of the static ac load flow equations, we conduct a similar investigation for ac grids. In a regular two-dimensional grid graph with cyclic boundary conditions, we find a power law decay for the change of power flow as a function of distance to the disturbance over a wide range of distances. The power exponent increases and saturates for large system sizes. By applying the same analysis to the German transmission grid topology, we show that also in real-world topologies a long-ranged response can be found. PMID:27575148

  16. Long-range response in ac electricity grids

    NASA Astrophysics Data System (ADS)

    Jung, Daniel; Kettemann, Stefan

    2016-07-01

    Local changes in the topology of electricity grids can cause overloads far away from the disturbance [D. Witthaut and M. Timme, Eur. Phys. J. B 86, 377 (2013), 10.1140/epjb/e2013-40469-4], making the prediction of the robustness against changes in the topology—for example, caused by power outages or grid extensions—a challenging task. The impact of single-line additions on the long-range response of dc electricity grids has recently been studied [D. Labavić, R. Suciu, H. Meyer-Ortmanns, and S. Kettemann, Eur. Phys. J.: Spec. Top. 223, 2517 (2014), 10.1140/epjst/e2014-02273-0]. By solving the real part of the static ac load flow equations, we conduct a similar investigation for ac grids. In a regular two-dimensional grid graph with cyclic boundary conditions, we find a power law decay for the change of power flow as a function of distance to the disturbance over a wide range of distances. The power exponent increases and saturates for large system sizes. By applying the same analysis to the German transmission grid topology, we show that also in real-world topologies a long-ranged response can be found.

  17. Cyclotron and linac production of Ac-225.

    PubMed

    Melville, Graeme; Allen, Barry J

    2009-04-01

    Radium needles that were once implanted into tumours as a cancer treatment are now obsolete and constitute a radioactive waste problem, as their half-life is 1600 years. The reduction of radium by photonuclear transmutation by bombarding Ra-226 with high-energy photons from a medical linear accelerator (linac) has been investigated. A linac dose of 2800 Gy produced about 2.4 MBq (64 microCi) of Ra-225, which decays to Ac-225 and can then be used for 'Targeted Alpha Therapy' (TAT) of cancer. This result, while consistent with theoretical calculations, is far too low to be of practical use unless much larger quantities of radium are irradiated. The increasing application of Ac-225 for cancer therapy indicates the potential need for its increased production and availability. This paper investigates the possibility of producing of Ac-225 in commercial quantities, which could potentially reduce obsolete radioactive material and displace the need for expensive importation of Ac-225 from the USA and Russia in the years ahead. Scaled up production of Ac-225 could theoretically be achieved by the use of a high current cyclotron or linac. Production specifications are determined for a linac in terms of current, pulse length and frequency, as well as an examination of other factors such as radiation issues and radionuclei separation. Yields are compared with those calculated for the Australian National Cyclotron in Sydney. PMID:19135381

  18. Implementation of a galvanically isolated low-noise power supply board for multi-channel headstage preamplifiers.

    PubMed

    Tóth, Attila; Máthé, Kálmán; Petykó, Zoltán; Szabó, Imre; Czurkó, András

    2008-06-15

    Custom made multi-channel headstage preamplifiers are traditionally powered by battery. By the use of an isolated unregulated DC/DC converter integrated circuit (DCP010512B from Texas Instruments Inc., TX, USA), here we describe the implementation of a galvanically isolated low-noise power supply board for multi-channel headstage preamplifiers. The implemented galvanically isolated power supply board provides the same quality noise free recording as the battery power supply. The non-isolated part of the power supply board is powered by standard 230 V AC/6 V DC wall mount adapter or USB cable. The described galvanically isolated power supply board can replace the batteries in preamplifier power supplies without any deterioration of the quality of recordings. PMID:18372046

  19. Survey of endogenous virus and TVB* receptor status of commercial chicken stocks supplying specific-pathogen-free eggs

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The ALVE endogenous virus and the ALVE receptor status of six commercial lines supplying specific pathogen free eggs were analyzed. Commercial lines A, E and F contained replication competent ALVE inserts. Line A was fixed for ALVE21 and lines E and F were segregating for ALVE10. In addition ALVE1 ...

  20. Survey and analysis of line-frequency interference in the CEBAF accelerator

    SciTech Connect

    Tiefenback, M.G.; Li, Rui

    1995-12-31

    Feedthrough of interference from the AC power line into accelerator components is a problem which in pulsed accelerators can be reduced by operation synchronous with the AC line. This means of avoiding line-frequency effects is ineffective for continuous wave machines such as the CEBAF accelerator. We have measured line-frequency perturbations at CEBAF both in beam position and energy by using the beam position monitor system as a multiple-channel sampling oscilloscope. Comparing these data against the measured static optics (taken synchronously with the AC line) we have been able to identify point sources of interference, and resolve line-synchronous variations in the beam energy at a level near 0.001%. 3 refs., 2 figs., 1 tab.

  1. AC impedance study of degradation of porous nickel battery electrodes

    NASA Technical Reports Server (NTRS)

    Lenhart, Stephen J.; Macdonald, D. D.; Pound, B. G.

    1987-01-01

    AC impedance spectra of porous nickel battery electrodes were recorded periodically during charge/discharge cycling in concentrated KOH solution at various temperatures. A transmission line model (TLM) was adopted to represent the impedance of the porous electrodes, and various model parameters were adjusted in a curve fitting routine to reproduce the experimental impedances. Degradation processes were deduced from changes in model parameters with electrode cycling time. In developing the TLM, impedance spectra of planar (nonporous) electrodes were used to represent the pore wall and backing plate interfacial impedances. These data were measured over a range of potentials and temperatures, and an equivalent circuit model was adopted to represent the planar electrode data. Cyclic voltammetry was used to study the characteristics of the oxygen evolution reaction on planar nickel electrodes during charging, since oxygen evolution can affect battery electrode charging efficiency and ultimately electrode cycle life if the overpotential for oxygen evolution is sufficiently low.

  2. ac propulsion system for an electric vehicle

    NASA Technical Reports Server (NTRS)

    Geppert, S.

    1980-01-01

    It is pointed out that dc drives will be the logical choice for current production electric vehicles (EV). However, by the mid-80's, there is a good chance that the price and reliability of suitable high-power semiconductors will allow for a competitive ac system. The driving force behind the ac approach is the induction motor, which has specific advantages relative to a dc shunt or series traction motor. These advantages would be an important factor in the case of a vehicle for which low maintenance characteristics are of primary importance. A description of an EV ac propulsion system is provided, taking into account the logic controller, the inverter, the motor, and a two-speed transmission-differential-axle assembly. The main barrier to the employment of the considered propulsion system in EV is not any technical problem, but inverter transistor cost.

  3. ACS Data Handbook v.6.0

    NASA Astrophysics Data System (ADS)

    Gonzaga, S.; et al.

    2011-03-01

    ACS was designed to provide a deep, wide-field survey capability from the visible to near-IR using the Wide Field Camera (WFC), high resolution imaging from the near-UV to near-IR with the now-defunct High Resolution Camera (HRC), and solar-blind far-UV imaging using the Solar Blind Camera (SBC). The discovery efficiency of ACS's Wide Field Channel (i.e., the product of WFC's field of view and throughput) is 10 times greater than that of WFPC2. The failure of ACS's CCD electronics in January 2007 brought a temporary halt to CCD imaging until Servicing Mission 4 in May 2009, when WFC functionality was restored. Unfortunately, the high-resolution optical imaging capability of HRC was not recovered.

  4. The Anaesthesia Gas Supply System

    PubMed Central

    Das, Sabyasachi; Chattopadhyay, Subhrajyoti; Bose, Payel

    2013-01-01

    The anaesthesia gas supply system is designed to provide a safe, cost-effective and convenient system for the delivery of medical gases at the point of-use. The doctrine of the anaesthesia gas supply system is based on four essential principles: Identity, continuity, adequacy and quality. Knowledge about gas supply system is an integral component of safe anaesthetic practice. Mishaps involving the malfunction or misuse of medical gas supply to operating theatres have cost many lives. The medical gases used in anaesthesia and intensive care are oxygen, nitrous oxide, medical air, entonox, carbon dioxide and heliox. Oxygen is one of the most widely used gases for life-support and respiratory therapy besides anaesthetic procedures. In this article, an effort is made to describe the production, storage and delivery of anaesthetic gases. The design of anaesthesia equipment must take into account the local conditions such as climate, demand and power supply. The operational policy of the gas supply system should have a backup plan to cater to the emergency need of the hospital, in the event of the loss of the primary source of supply. PMID:24249882

  5. Water supply and demand in an energy supply model

    SciTech Connect

    Abbey, D; Loose, V

    1980-12-01

    This report describes a tool for water and energy-related policy analysis, the development of a water supply and demand sector in a linear programming model of energy supply in the United States. The model allows adjustments in the input mix and plant siting in response to water scarcity. Thus, on the demand side energy conversion facilities can substitute more costly dry cooling systems for conventional evaporative systems. On the supply side groundwater and water purchased from irrigators are available as more costly alternatives to unappropriated surface water. Water supply data is developed for 30 regions in 10 Western states. Preliminary results for a 1990 energy demand scenario suggest that, at this level of spatial analysis, water availability plays a minor role in plant siting. Future policy applications of the modeling system are discussed including the evaluation of alternative patterns of synthetic fuels development.

  6. Topsensterols A-C, Cytotoxic Polyhydroxylated Sterol Derivatives from a Marine Sponge Topsentia sp.

    PubMed

    Chen, Min; Wu, Xu-Dong; Zhao, Qing; Wang, Chang-Yun

    2016-01-01

    Three new polyhydroxylated sterol derivatives topsensterols A-C (1-3) have been isolated from a marine sponge Topsentia sp. collected from the South China Sea. Their structures were elucidated by detailed analysis of the spectroscopic data, especially the NOESY spectra. Topsensterols A-C (l-3) possess novel 2β,3α,4β,6α-tetrahydroxy-14α-methyl Δ(9(11)) steroidal nuclei with unusual side chains. Compound 2 exhibited cytotoxicity against human gastric carcinoma cell line SGC-7901 with an IC50 value of 8.0 μM. Compound 3 displayed cytotoxicity against human erythroleukemia cell line K562 with an IC50 value of 6.0 μM. PMID:27490555

  7. AC loss in superconducting tapes and cables

    NASA Astrophysics Data System (ADS)

    Oomen, Marijn Pieter

    High-temperature superconductors are developed for use in power-transmission cables, transformers and motors. The alternating magnetic field in these devices causes AC loss, which is a critical factor in the design. The study focuses on multi-filament Bi-2223/Ag tapes exposed to a 50-Hz magnetic field at 77 K. The AC loss is measured with magnetic, electric and calorimetric methods. The results are compared to theoretical predictions based mainly on the Critical-State Model. The loss in high- temperature superconductors is affected by their characteristic properties: increased flux creep, high aspect ratio and inhomogeneties. Filament intergrowths and a low matrix resistivity cause a high coupling-current loss especially when the filaments are fully coupled. When the wide side of the tape is parallel to the external magnetic field, the filaments are decoupled by twisting. In a perpendicular field the filaments can be decoupled only by combining a short twist pitch with a transverse resistivity much higher than that of silver. The arrangement of the inner filaments determines the transverse resistivity. Ceramic barriers around the filaments cause partial decoupling in perpendicular magnetic fields at power frequencies. The resultant decrease in AC loss is greater than the accompanying decrease in critical current. With direct transport current in alternating magnetic field, the transport-current loss is well described with a new model for the dynamic resistance. The Critical- State Model describes well the magnetisation and total AC loss in parallel magnetic fields, at transport currents up to 0.7 times the critical current. When tapes are stacked face-to-face in a winding, the AC-loss density in perpendicular fields is greatly decreased due to the mutual shielding of the tapes. Coupling currents between the tapes in a cable cause an extra AC loss, which is reduced by a careful cable design. The total AC loss in complex devices with many tapes is generally well

  8. Petroleum supply monthly, April 1994

    SciTech Connect

    Not Available

    1994-04-01

    Data presented in the Petroleum Supply Monthly (PSM) describe the supply and disposition of petroleum products in the United States and major US geographical regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the US. The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the US.

  9. Petroleum supply monthly, February 1994

    SciTech Connect

    Not Available

    1994-03-01

    The Petroleum Supply Monthly presents data describing the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the US. The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders; operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. Data are divided into two sections: Summary statistics and Detailed statistics.

  10. Multiple resonant railgun power supply

    SciTech Connect

    Honig, E.M.; Nunnally, W.C.

    1985-06-19

    A multiple repetitive resonant railgun power supply provides energy for repetitively propelling projectiles from a pair of parallel rails. A plurality of serially connected paired parallel rails are powered by similar power supplies. Each supply comprises an energy storage capacitor, a storage inductor to form a resonant circuit with the energy storage capacitor and a magnetic switch to transfer energy between the resonant circuit and the pair of parallel rails for the propelling of projectiles. The multiple serial operation permits relatively small energy components to deliver overall relatively large amounts of energy to the projectiles being propelled.

  11. Multiple resonant railgun power supply

    SciTech Connect

    Honig, Emanuel M.; Nunnally, William C.

    1988-01-01

    A multiple repetitive resonant railgun power supply provides energy for repetitively propelling projectiles from a pair of parallel rails. A plurality of serially connected paired parallel rails are powered by similar power supplies. Each supply comprises an energy storage capacitor, a storage inductor to form a resonant circuit with the energy storage capacitor and a magnetic switch to transfer energy between the resonant circuit and the pair of parallel rails for the propelling of projectiles. The multiple serial operation permits relatively small energy components to deliver overall relatively large amounts of energy to the projectiles being propelled.

  12. Brazilian Angiostrongylus cantonensis haplotypes, ac8 and ac9, have two different biological and morphological profiles

    PubMed Central

    Monte, Tainá CC; Gentile, Rosana; Garcia, Juberlan; Mota, Ester; Santos, Jeannie N; Maldonado, Arnaldo

    2014-01-01

    Angiostrongylus cantonensis is the etiologic agent of eosinophilic meningoencephalitis in humans. Cases have been recorded in many parts of the world, including Brazil. The aim of this study was to compare the differences in the biology and morphology of two different Brazilian haplotypes of A. : ac8 and ac9. A significantly larger number of L1 larvae eliminated in the faeces of rodents at the beginning of the patent period was observed for ac9 haplotype and compared to the total of L1 larvae eliminated, there was a significant difference between the two haplotypes. The ac9 haplotype showed a significant difference in the proportion of female and male specimens (0.6:1), but the same was not observed for ac8 (1.2:1). The morphometric analysis showed that male and female specimens isolated from ac8 haplotype were significantly larger with respect to body length, oesophagus length, spicule length (male) and distance from the anus to the rear end (female) compared to specimens from ac9. The morphological analysis by light microscopy showed little variation in the level of bifurcations at the lateral rays in the right lobe of the copulatory bursa between the two haplotypes. The biological, morphological and morphometric variations observed between the two haplotypes agree with the observed variation at the molecular level using the cytochrome oxidase subunit I marker and reinforce the possible influence of geographical isolation on the development of these haplotypes. PMID:25591110

  13. AcsA-AcsB: The core of the cellulose synthase complex from Gluconacetobacter hansenii ATCC23769.

    PubMed

    McManus, John B; Deng, Ying; Nagachar, Nivedita; Kao, Teh-hui; Tien, Ming

    2016-01-01

    The gram-negative bacterium, Gluconacetobacter hansenii, produces cellulose of exceptionally high crystallinity in comparison to the cellulose of higher plants. This bacterial cellulose is synthesized and extruded into the extracellular medium by the cellulose synthase complex (CSC). The catalytic component of this complex is encoded by the gene AcsAB. However, several other genes are known to encode proteins critical to cellulose synthesis and are likely components of the bacterial CSC. We have purified an active heterodimer AcsA-AcsB from G. hansenii ATCC23769 to homogeneity by two different methods. With the purified protein, we have determined how it is post-translationally processed, forming the active heterodimer AcsA-AcsB. Additionally, we have performed steady-state kinetic studies on the AcsA-AcsB complex. Finally through mutagenesis studies, we have explored the roles of the postulated CSC proteins AcsC, AcsD, and CcpAx. PMID:26672449

  14. Carrier and Envelope Frequency Measurements for Supply-Modulated Microwave Power Amplifiers

    NASA Astrophysics Data System (ADS)

    Schafer, Scott R.

    Transmitters for high peak-to-average power ratio communication are increasingly using supply modulation to improve efficiency. In addition to a dc component, the dynamic supply may contain ac components up to 500MHz. The signal envelope dynamic impedance of the supply terminal of a power amplifier (PA) is often unknown and available nonlinear transistor models are unable to predict dynamic low frequency effects required for design of wideband efficient supply modulators. This thesis investigates envelope frequency effects on nonlinear behavior of microwave transistors and PAs under supply-modulated conditions. A measurement setup is created to characterize multi-frequency large-signal excitation of GaN transistors and PAs at carrier frequencies in the 10GHz range with 1-500MHz low frequency excitation on the drain terminal. A novel method for multi-frequency analysis of nonlinear circuit components based on describing functions is developed. It is shown that the describing functions agree with simulation and measurements. In addition, the measurement setup is used to characterize the low frequency drain impedance of a MMIC PA when connected to a simple resonant supply modulator. The main motivation for this work is to obtain knowledge of the dynamic supply terminal in the low frequency regime (1-500MHz) that can enable power amplifier and supply modulator co-design for very broadband signals.

  15. Kalanchosides A-C, new cytotoxic bufadienolides from the aerial parts of Kalanchoe gracilis.

    PubMed

    Wu, Pei-Lin; Hsu, Yu-Lin; Wu, Tian-Shung; Bastow, K F; Lee, Kuo-Hsiung

    2006-11-01

    [Structure: see text] Three new compounds, kalanchosides A-C (1-3), as well as five known compounds, were isolated from the aerial parts of Kalanchoe gracilis. The compound structures were determined by spectroscopic methods. All eight isolated compounds showed significant cytotoxic activity against a panel of human tumor cell lines, with potency reaching the nanomolar range. However, only bryophyllin B (8) inhibited HIV replication in H9 lymphocyte cells. PMID:17078679

  16. 48 CFR 252.217-7026 - Identification of sources of supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Government is required under 10 U.S.C. 2384 to obtain certain information on the actual manufacturer or... following table before award: Table Line items National stock No. Commercial item (Y or N) Source of supply... technical data, list the source. (5) For items of supply, list each source's part number for the item....

  17. The 3He Supply Problem

    SciTech Connect

    Kouzes, Richard T.

    2009-05-01

    One of the main uses for 3He is in gas proportional counters for neutron detection. Radiation portal monitors deployed for homeland security and non-proliferation use such detectors. Other uses of 3He are for research detectors, commercial instruments, well logging detectors, dilution refrigerators, for targets or cooling in nuclear research, and for basic research in condensed matter physics. The US supply of 3He comes almost entirely from the decay of tritium used in nuclear weapons by the US and Russia. A few other countries contribute a small amount to the world’s 3He supply. Due to the large increase in use of 3He for homeland security, the supply has dwindled, and can no longer meet the demand. This white paper reviews the problems of supply, utilization, and alternatives.

  18. Predictive methodology for supply disruptions

    SciTech Connect

    Beller, M.; D'Acierno, J.

    1982-04-01

    Energy supply disruptions do not suddenly arise in a full-blown fashion. Lags in the energy system provide a time horizon which allows for the prediction of a possible supply problem. A simple model is described which can be used to provide a set of indicators for the possible onset of an energy emergency. The methodology was tested on the gasoline shortage of 1979, and the results are presented.

  19. ORION downconverter and power supply

    NASA Technical Reports Server (NTRS)

    Nishimura, H. G.

    1982-01-01

    The receiver subsystem supplies the front end assembly (downconverter) and power supply for the ORION Mobile Station. These assemblies are designed to withstand severe environmental conditions. The mechanical, electronic, environmental and maintenance design considerations encountered during the design phase of this project are discussed. The two channel S/X downconverter has a 400 MHz bandwidth channel. Phase stability of 2 and 7 deg at S- and X-bands, respectively, is achieved with a temperature stabilized first local oscillator.

  20. TRANSISTOR HIGH VOLTAGE POWER SUPPLY

    DOEpatents

    Driver, G.E.

    1958-07-15

    High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

  1. Detrimental effect of expression of Bt endotoxin Cry1Ac on in vitro regeneration, in vivo growth and development of tobacco and cotton transgenics.

    PubMed

    Rawat, Preeti; Singh, Amarjeet Kumar; Ray, Krishna; Chaudhary, Bhupendra; Kumar, Sanjeev; Gautam, Taru; Kanoria, Shaveta; Kaur, Gurpreet; Kumar, Paritosh; Pental, Deepak; Burma, Pradeep Kumar

    2011-06-01

    High levels of expression of the cry1Ac gene from Bacillus thuringiensis cannot be routinely achieved in transgenic plants despite modifications made in the gene to improve its expression. This has been attributed to the instability of the transcript in a few reports. In the present study, based on the genetic transformation of cotton and tobacco, we show that the expression of the Cry1Ac endotoxin has detrimental effects on both the in vitro and in vivo growth and development of transgenic plants. A number of experiments on developing transgenics in cotton with different versions of cry1Ac gene showed that the majority of the plants did not express any Cry1Ac protein. Based on Southern blot analysis, it was also observed that a substantial number of lines did not contain the cry1Ac gene cassette although they contained the marker gene nptII. More significantly, all the lines that showed appreciable levels of expression were found to be phenotypically abnormal. Experiments on transformation of tobacco with different constructs expressing the cry1Ac gene showed that in vitro regeneration was inhibited by the encoded protein. Further, out of a total of 145 independent events generated with the different cry1Ac gene constructs in tobacco, only 21 showed expression of the Cry1Ac protein, confirming observations made in cotton that regenerants that express high levels of the Cry1Ac protein are selected against during regeneration of transformed events. This problem was circumvented by targeting the Cry1Ac protein to the chloroplast, which also significantly improved the expression of the protein. PMID:21654089

  2. Reinforcement learning in supply chains.

    PubMed

    Valluri, Annapurna; North, Michael J; Macal, Charles M

    2009-10-01

    Effective management of supply chains creates value and can strategically position companies. In practice, human beings have been found to be both surprisingly successful and disappointingly inept at managing supply chains. The related fields of cognitive psychology and artificial intelligence have postulated a variety of potential mechanisms to explain this behavior. One of the leading candidates is reinforcement learning. This paper applies agent-based modeling to investigate the comparative behavioral consequences of three simple reinforcement learning algorithms in a multi-stage supply chain. For the first time, our findings show that the specific algorithm that is employed can have dramatic effects on the results obtained. Reinforcement learning is found to be valuable in multi-stage supply chains with several learning agents, as independent agents can learn to coordinate their behavior. However, learning in multi-stage supply chains using these postulated approaches from cognitive psychology and artificial intelligence take extremely long time periods to achieve stability which raises questions about their ability to explain behavior in real supply chains. The fact that it takes thousands of periods for agents to learn in this simple multi-agent setting provides new evidence that real world decision makers are unlikely to be using strict reinforcement learning in practice. PMID:19885962

  3. Petroleum supply monthly, April 1990

    SciTech Connect

    1990-06-26

    The Petroleum Supply Monthly (PSM) is one of a family of three publications produced by the Petroleum Supply Division within the Energy Information Administration (EIA) reflecting different levels of data timeliness and completeness. The other two publications are the Weekly Petroleum Status Report (WPSR) and the Petroleum Supply Annual (PSA). Data presented in the Petroleum Supply Monthly describe (PSM) the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in Primary Supply.'' Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections: (1) the Summary Statistics and (2) the Detailed Statistics.

  4. Analysis of residual chlorine in simple drinking water distribution system with intermittent water supply

    NASA Astrophysics Data System (ADS)

    Goyal, Roopali V.; Patel, H. M.

    2015-09-01

    Knowledge of residual chlorine concentration at various locations in drinking water distribution system is essential final check to the quality of water supplied to the consumers. This paper presents a methodology to find out the residual chlorine concentration at various locations in simple branch network by integrating the hydraulic and water quality model using first-order chlorine decay equation with booster chlorination nodes for intermittent water supply. The explicit equations are developed to compute the residual chlorine in network with a long distribution pipe line at critical nodes. These equations are applicable to Indian conditions where intermittent water supply is the most common system of water supply. It is observed that in intermittent water supply, the residual chlorine at farthest node is sensitive to water supply hours and travelling time of chlorine. Thus, the travelling time of chlorine can be considered to justify the requirement of booster chlorination for intermittent water supply.

  5. Manipulating Flames with AC Electric Fields

    NASA Astrophysics Data System (ADS)

    Bishop, Kyle

    2013-11-01

    Time-oscillating electric fields applied to plasmas present in flames create steady flows of gas capable of shaping, directing, enhancing, or even extinguishing flames. Interestingly, electric winds induced by AC electric fields can be stronger that those due to static fields of comparable magnitude. Furthermore, unlike static fields, the electric force due to AC fields is localized near the surface of the flame. Consequently, the AC response depends only on the local field at the surface of the flame - not on the position of the electrodes used to generate the field. These results suggest that oscillating electric fields can be used to manipulate and control combustion processes at a distance. To characterize and explain these effects, we investigate a simple experimental system comprising a laminar methane-air flame positioned between two parallel-plate electrodes. We quantify both the electric and hydrodynamic response of the flame as a function of frequency and magnitude of the applied field. A theoretical model shows how steady gas flows emerge from the time-averaged electrical force due to the field-induced motion of ions generated within the flame and by their disappearance by recombination. These results provide useful insights into the application of AC fields to direct combustion processes.

  6. AC electric trapping of neutral atoms

    NASA Astrophysics Data System (ADS)

    Marian, Adela; Schlunk, Sophie; Schoellkopf, Wieland; Meijer, Gerard

    2008-05-01

    We have demonstrated trapping of ultracold ground-state ^87Rb atoms in a macroscopic ac electric trap [1]. Trapping by ac electric fields has been previously achieved for polar molecules [2], as well as Sr atoms on a chip [3], and recently for Rb atoms in a three-phase electric trap [4]. Similar to trapping of ions in a Paul trap, three-dimensional confinement in an ac electric trap is obtained by switching between two saddle-point configurations of the electric field. For the first time, this dynamic confinement is directly visualized with absorption images taken at different phases of the ac switching cycle. Stable electric trapping is observed in a narrow range of switching frequencies around 60 Hz, in agreement with trajectory calculations. In a typical experiment, about 3 x 10^5 Rb atoms are trapped with lifetimes on the order of 9 s and trap depths of about 10 μK. Additionally, we show that the atoms can be used to sensitively probe the electric fields in the trap by imaging the cloud while the fields are still on. References: 1. S. Schlunk et al., PRL 98, 223002 (2007) 2. H. L. Bethlem et al., PRA 74, 063403 (2006) 3. T. Kishimoto et al., PRL 96, 123001 (2006) 4. T. Rieger et al., PRL 99, 063001 (2007)

  7. AC power generation from microbial fuel cells

    NASA Astrophysics Data System (ADS)

    Lobo, Fernanda Leite; Wang, Heming; Forrestal, Casey; Ren, Zhiyong Jason

    2015-11-01

    Microbial fuel cells (MFCs) directly convert biodegradable substrates to electricity and carry good potential for energy-positive wastewater treatment. However, the low and direct current (DC) output from MFC is not usable for general electronics except small sensors, yet commercial DC-AC converters or inverters used in solar systems cannot be directly applied to MFCs. This study presents a new DC-AC converter system for MFCs that can generate alternating voltage in any desired frequency. Results show that AC power can be easily achieved in three different frequencies tested (1, 10, 60 Hz), and no energy storage layer such as capacitors was needed. The DC-AC converter efficiency was higher than 95% when powered by either individual MFCs or simple MFC stacks. Total harmonic distortion (THD) was used to investigate the quality of the energy, and it showed that the energy could be directly usable for linear electronic loads. This study shows that through electrical conversion MFCs can be potentially used in household electronics for decentralized off-grid communities.

  8. AC magnetic susceptibility of Bi2223-system

    NASA Astrophysics Data System (ADS)

    Kimishima, Y.; Inagaki, K.; Tanabe, K.; Nagata, N.; Ichiyanagi, Y.

    1998-01-01

    The AC magnetic susceptibilities χ AC of a Bi2223 sintered sample were measured by the Hartshorn bridge method. The linear AC χ' 0 showed the two-steps behavior at T C1 and T C2, where T C1 > T C2. The χ'0-data between T C1 and T C2 has no H AC-dependence and agreed well with those of powder specimen, and they can be regarded as the intragrain magnetic susceptibility. Below the inter-grain transition temperature T C2 the χ″ 0 showed a positive peak. The temperature dependence of χ' 0 and χ″ 0 were analyzed by the Bean's critical-state model. As a result, the temperature dependence of critical current density J C ∝ (1 - T/T C2) β was obtained with β = 2.3-2.6. The non-linear χ' 2 and χ″ 2 below T C2 resemble the behaviors derived from the Bean model, but the negative divergence of χ' 2 may show the evidence of d-wave paring in the present Bi2223-system.

  9. 76 FR 65633 - RIN 1904-AC43

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-24

    ... FR 56678 (September 14, 2011) to make available and invite comments on the framework document for... Part 430 RIN 1904-AC43 Energy Conservation Program: Framework Document for General Service Fluorescent... general service fluorescent lamps and incandescent reflector lamps energy conservation standards in...

  10. ACS Task Force Frames Recommendations on Education.

    ERIC Educational Resources Information Center

    Chemical and Engineering News, 1984

    1984-01-01

    Discusses findings and recommendations of an American Chemical Society (ACS) task force study on the status of chemical education in the United States. Recommendations relate to national concerns; all educational levels; elementary, secondary, university, college, and two-year college chemistry and science; chemistry careers; and industry and…

  11. E-beam high voltage switching power supply

    DOEpatents

    Shimer, Daniel W.; Lange, Arnold C.

    1997-01-01

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

  12. E-beam high voltage switching power supply

    DOEpatents

    Shimer, D.W.; Lange, A.C.

    1997-03-11

    A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

  13. High voltage AC/AC electrochemical capacitor operating at low temperature in salt aqueous electrolyte

    NASA Astrophysics Data System (ADS)

    Abbas, Qamar; Béguin, François

    2016-06-01

    We demonstrate that an activated carbon (AC)-based electrochemical capacitor implementing aqueous lithium sulfate electrolyte in 7:3 vol:vol water/methanol mixture can operate down to -40 °C with good electrochemical performance. Three-electrode cell investigations show that the faradaic contributions related with hydrogen chemisorption in the negative AC electrode are thermodynamically unfavored at -40 °C, enabling the system to work as a typical electrical double-layer (EDL) capacitor. After prolonged floating of the AC/AC capacitor at 1.6 V and -40°C, the capacitance, equivalent series resistance and efficiency remain constant, demonstrating the absence of ageing related with side redox reactions at this temperature. Interestingly, when temperature is increased back to 24 °C, the redox behavior due to hydrogen storage reappears and the system behaves as a freshly prepared one.

  14. 48 CFR Appendixes A-C to Chapter 7 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false A Appendixes A-C to Chapter 7 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT Appendixes A-C to Chapter 7...

  15. 48 CFR Appendixes A-C to Chapter 7 - [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false A Appendixes A-C to Chapter 7 Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT Appendixes A-C to Chapter 7...

  16. Intraspecific and Interspecific Variation at the Y-Ac-Sc Region of Drosophila Simulans and Drosophila Melanogaster

    PubMed Central

    Martin-Campos, J. M.; Comeron, J. M.; Miyashita, N.; Aguade, M.

    1992-01-01

    A 2.2-kb region including the ac gene of Drosophila simulans has been sequenced. Interspecific divergence between Drosophila melanogaster and D. simulans was estimated as 0.0695 and 0.0558 for silent and for all sites, respectively. Estimated silent site divergence for the ac region is comparable to that estimated for other regions of the genome between these species, indicating that silent sites of the ac region are not under significantly stronger functional constraint. Intraspecific variation in both species was also investigated. Restriction-site and length polymorphism in the ac region of D. simulans has been investigated for 103 X chromosome lines sampled from three natural populations in Spain using eight four-cutter restriction enzymes. Neither restriction-site nor length variation was detected in the three populations surveyed. In D. melanogaster restriction-site and length polymorphism in all major transcription units of the y-ac-sc region (23.1-kb region) has been studied using four four-cutter restriction enzymes for 245 X chromosome lines sampled from 10 natural populations (seven from Europe, two from North America and one from Japan). Fourteen restriction-site and 28 length polymorphisms were detected. There was some indication of population subdivision for North American vs. European samples of D. melanogaster. The frequency spectrum of restriction-site polymorphisms in European populations was skewed toward rarer frequencies than predicted by the neutral theory. Comparison of silent site variation at this telomeric region with that in the Adh 5'-flanking region showed a reduced level of heterozygosity in the y-ac-sc region. Since interspecific silent divergence is not reduced in the y-ac-sc region as compared to other regions, the reduction in standing levels of variation at this telomeric locus in both D. simulans and D. melanogaster is most easily explained by a hitchhiking effect of linked selected substitutions. PMID:1582559

  17. Radioimmunotherapy of breast cancer metastases with alpha-particle emitter 225Ac: comparing efficacy with 213Bi and 90Y.

    PubMed

    Song, Hong; Hobbs, Robert F; Vajravelu, Ravy; Huso, David L; Esaias, Caroline; Apostolidis, Christos; Morgenstern, Alfred; Sgouros, George

    2009-12-01

    alpha-Particles are suitable to treat cancer micrometastases because of their short range and very high linear energy transfer. alpha-Particle emitter (213)Bi-based radioimmunotherapy has shown efficacy in a variety of metastatic animal cancer models, such as breast, ovarian, and prostate cancers. Its clinical implementation, however, is challenging due to the limited supply of (225)Ac, high technical requirement to prepare radioimmunoconjugate with very short half-life (T(1/2) = 45.6 min) on site, and prohibitive cost. In this study, we investigated the efficacy of the alpha-particle emitter (225)Ac, parent of (213)Bi, in a mouse model of breast cancer metastases. A single administration of (225)Ac (400 nCi)-labeled anti-rat HER-2/neu monoclonal antibody (7.16.4) completely eradicated breast cancer lung micrometastases in approximately 67% of HER-2/neu transgenic mice and led to long-term survival of these mice for up to 1 year. Treatment with (225)Ac-7.16.4 is significantly more effective than (213)Bi-7.16.4 (120 microCi; median survival, 61 days; P = 0.001) and (90)Y-7.16.4 (120 microCi; median survival, 50 days; P < 0.001) as well as untreated control (median survival, 41 days; P < 0.0001). Dosimetric analysis showed that (225)Ac-treated metastases received a total dose of 9.6 Gy, significantly higher than 2.0 Gy from (213)Bi and 2.4 Gy from (90)Y. Biodistribution studies revealed that (225)Ac daughters, (221)Fr and (213)Bi, accumulated in kidneys and probably contributed to the long-term renal toxicity observed in surviving mice. These data suggest (225)Ac-labeled anti-HER-2/neu monoclonal antibody could significantly prolong survival in HER-2/neu-positive metastatic breast cancer patients. PMID:19920193

  18. Protective supplied-breathing-air garment

    DOEpatents

    Childers, E.L.; von Hortenau, E.F.

    1982-05-28

    A breathing-air garment for isolating a wearer from hostile environments containing toxins or irritants is disclosed. The garment includes a suit and a separate head-protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air-delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air-delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit sealed with an adhesive sealing flap.

  19. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 11 2011-01-01 2011-01-01 false Area Coverage Survey (ACS). 1737.31 Section 1737.31... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage Survey (ACS) is a market forecast of service requirements of subscribers in a proposed service area....

  20. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 11 2012-01-01 2012-01-01 false Area Coverage Survey (ACS). 1737.31 Section 1737.31... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage Survey (ACS) is a market forecast of service requirements of subscribers in a proposed service area....

  1. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Area Coverage Survey (ACS). 1737.31 Section 1737.31... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage Survey (ACS) is a market forecast of service requirements of subscribers in a proposed service area....

  2. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 11 2013-01-01 2013-01-01 false Area Coverage Survey (ACS). 1737.31 Section 1737.31... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage Survey (ACS) is a market forecast of service requirements of subscribers in a proposed service area....

  3. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage Survey (ACS) is a market forecast of service requirements of subscribers in a proposed service area. (b... 7 Agriculture 11 2014-01-01 2014-01-01 false Area Coverage Survey (ACS). 1737.31 Section...

  4. 21 CFR 886.1630 - AC-powered photostimulator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false AC-powered photostimulator. 886.1630 Section 886.1630 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...) Identification. An AC-powered photostimulator is an AC-powered device intended to provide light stimulus...

  5. Methods for Addressing Missing Data with Applications from ACS Exams

    ERIC Educational Resources Information Center

    Brandriet, Alexandra; Holme, Thomas

    2015-01-01

    As part of the ACS Examinations Institute (ACS-EI) national norming process, student performance data sets are collected from professors at colleges and universities from around the United States. Because the data sets are collected on a volunteer basis, the ACS-EI often receives data sets with only students' total scores and without the students'…

  6. 21 CFR 886.1630 - AC-powered photostimulator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false AC-powered photostimulator. 886.1630 Section 886.1630 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...) Identification. An AC-powered photostimulator is an AC-powered device intended to provide light stimulus...

  7. High Power Amplifier and Power Supply

    NASA Technical Reports Server (NTRS)

    Duong, Johnny; Stride, Scot; Harvey, Wayne; Haque, Inam; Packard, Newton; Ng, Quintin; Ispirian, Julie Y.; Waian, Christopher; Janes, Drew

    2008-01-01

    A document discusses the creation of a high-voltage power supply (HVPS) that is able to contain voltages up to -20 kV, keep electrical field strengths to below 200 V/mil (approximately equal to 7.87 kV/mm), and can provide a 200-nanosecond rise/fall time focus modulator swinging between cathode potential of 16.3 kV and -19.3 kV. This HVPS can protect the 95-GHz, pulsed extended interaction klystron (EIK) from arcs/discharges from all sources, including those from within the EIK fs vacuum envelope. This innovation has a multi-winding pulse transformer design, which uses new winding techniques to provide the same delays and rise/fall times (less than 10 nanoseconds) at different potential levels ranging from -20 kV to -16 kV. Another feature involves a high-voltage printed-wiring board that was corona-free at -20 kV DC with a 3- kV AC swing. The corona-free multilayer high-voltage board is used to simulate fields of less than 200 V/mil (approximately equal to 7.87 kV/mm) at 20 kV DC. Drive techniques for the modulator FETs (field-effect transistors) (four to 10 in a series) were created to change states (3,000-V swing) without abrupt steps, while still maintaining required delays and transition times. The packing scheme includes a potting mold to house a ten-stage modulator in the space that, in the past, only housed a four-stage modulator. Problems keeping heat down were solved using aluminum oxide substrate in the high-voltage section to limit temperature rise to less than 10 while withstanding -20 kV DC voltage and remaining corona-free.

  8. Electric power high-voltage transmission lines: Design options, cost, and electric and magnetic field levels

    SciTech Connect

    Stoffel, J.B.; Pentecost, E.D.; Roman, R.D.; Traczyk, P.A.

    1994-11-01

    This report provides background information about (1) the electric and magnetic fields (EMFs) of high-voltage transmission lines at typical voltages and line configurations and (2) typical transmission line costs to assist on alternatives in environmental documents. EMF strengths at 0 {+-} 200 ft from centerline were calculated for ac overhead lines, and for 345 and 230-kV ac underground line and for a {+-}450-kV dc overhead line. Compacting and height sensitivity factors were computed for the variation in EMFs when line conductors are moved closer or raised. Estimated costs for the lines are presented and discussed so that the impact of using alternative strategies for reducing EMF strengths and the implications of implementing the strategies can be better appreciated.

  9. Petroleum Supply Monthly, August 1990

    SciTech Connect

    Not Available

    1990-10-30

    The Petroleum Supply Monthly (PSM) is one of a family of three publications produced by the Petroleum Supply Division within the Energy Information administration (EIA) reflecting different levels of data timeliness and completeness. The other two publications are the Weekly Petroleum Status Report (WPSR) and the Petroleum Supply Annual (PSA). Data presented in the PSM describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) district movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in Primary Supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections (1) the Summary Statistics and (2) the Detailed Statistics.

  10. Petroleum supply monthly, June 1994

    SciTech Connect

    Not Available

    1994-06-28

    The Petroleum Supply Monthly (PSM) is one of a family of four publications produced by the Petroleum Supply Division within the Energy Information Administration (EIA) reflecting different levels of data timeliness and completeness. The other publications are the Weekly Petroleum Status Report (WPSR), the Winter Fuels Report, and the Petroleum Supply Annual (PSA). Data presented in the PSM describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections: Summary Statistics and Detailed Statistics.

  11. Petroleum supply monthly, May 1994

    SciTech Connect

    Not Available

    1994-05-27

    The Petroleum Supply Monthly (PSM) is one of a family of four publications produced by the Petroleum Supply Division within the Energy Information Administration (EIA) reflecting different levels of data timeliness and completeness. The other publications are the Weekly Petroleum Status Report (WPSR), the Winter Fuels Report, and the Petroleum supply annual (PSA). Data presented in the PSM describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections: Summary Statistics and Detailed Statistics.

  12. Petroleum supply monthly, September 1991

    SciTech Connect

    Not Available

    1991-09-30

    The Petroleum Supply Monthly (PSM) is one of a family of three publications produced by the Petroleum Supply Division within the Energy Information Administration (EIA) reflecting different levels of data timeliness and completeness. The other two publications are the Weekly Petroleum Status Report (WPSR) and the Petroleum Supply Annual (PSA). Data presented in PSM describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administrations for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 states and the District of Columbia). The reporting universe includes those petroleum sectors in Primary Supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections (1) the Summary Statistics and (2) the Detailed Statistics. 65 tabs.

  13. Petroleum supply monthly, July 1994

    SciTech Connect

    Not Available

    1994-07-26

    The Petroleum Supply Monthly (PSM) is one of a family of four publications produced by the Petroleum Supply Division within the Energy Information Administration (EIA) reflecting different levels of data timeliness and completeness. The other publications are the Weekly Petroleum Status Report (WPSR), the Winter Fuels Report, and the Petroleum Supply Annual (PSA). Data presented in the PSM describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections: Summary Statistics and Detailed Statistics.

  14. Petroleum supply monthly, October 1993

    SciTech Connect

    Not Available

    1993-10-26

    The Petroleum Supply Monthly (PSM) is one of a family of four publications produced by the Petroleum Supply Division within the Energy Information Administration (EIA) reflecting different levels of data timeliness and completeness. The other publications are the Weekly Petroleum Status Report (WPSR), the Winter Fuels Report, and the Petroleum Supply Annual (PSA). Data presented in the PSM describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections: Summary Statistics and Detailed Statistics.

  15. Petroleum supply monthly, January 1996

    SciTech Connect

    1996-02-15

    The Petroleum Supply Monthly (PSM) is one of a family of four publications produced by the Petroleum Supply Division within the Energy Information Administration (EIA) reflecting different levels of data timeliness and completeness. The other publications are the Weekly Petroleum Status Report (WPSR), the Winter Fuels Report, and the Petroleum Supply Annual (PSA). Data presented in the PSM describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections: Summary Statistics and Detailed Statistics.

  16. Fuzzy based power factor improvement strategy for a multiple connected AC-DC converter fed drive

    NASA Astrophysics Data System (ADS)

    Radhakrishnan, N.; Muthiah, Ramaswamy

    2012-01-01

    The main focus of this paper is to design a Fuzzy based control algorithm to realize an improvement in the input power factor of a multiple connected AC-DC converter fed drive system. It incorporates the role of fuzzy inference principles to generate appropriate PWM pulses for the power switches at the second stage of the power module. The philosophy is developed, with a view to reshape the input current phasor and enables it to align with the supply voltage wave in the perspective of improving the input power factor. The closed loop scheme evaluated using MATLAB based simulation exhibits an enhancement in supply power factor over a range of operating loads in addition to illustrating the speed regulating capability of the drive.

  17. ACS grism spectra in the HDF-North

    NASA Astrophysics Data System (ADS)

    Meurer, G. R.; Tsvetanov, Z. I.; Gronwall, C.; Benitez, N.; Franx, M.; Blakeslee, J. P.; Cross, N.; Ford, H. C.; Martel, A. R.; Tran, H. D.; Illingworth, G. D.; Clampin, M.; Postman, M.; Allen, T.; Anderson, K.; Ardila, D. R.; Feldman, P. D.; Golimowski, D. A.; McCann, Wm. J.; Menanteau, F.; Sirianni, M.; Zheng, W.; Brown, R. A.; Burrows, C.; Hartig, G.; Krist, J.; Sparks, W. B.; White, R. L.; Cheng, E.; Kimble, R. A.; Campbell, D.; Sullivan, P.; Bouwens, R.; Magee, D.; Bartko, F.; Broadhurst, T. J.; Infante, L.; Lesser, M.; Miley, G.; Rosati, P.; Volmer, P.; Rafal, M.; Woodruff, R. A.

    2002-12-01

    We present slitless spectra of sources in the Hubble Deep Field North obtained with the Advanced Camera for Surveys. The Wide Field Camera was used to obtain dithered observations with a total exposure of 6700s (3 orbits) with the G800L grism. We concentrate on objects with published redshifts obtained spectroscopically and photometrically. In addition, we use a semi-automated technique to identify sources with emission line spectra, and those with broad stellar features. Sources with emission lines having a peak S/N > 4, have a median mF775W = 24.6 ABmag. This is 1.5 mag fainter than the median mF775W of objects in the Cohen et al. (2000, ApJ, 538, 29) spectroscopic redshift survey, illustrating that the G800L is a potentially useful tool for obtaining spectroscopic data of faint compact sources. ACS was developed under NASA contract NAS 5-32865, and this research is supported by NASA grant NAG5-7697. We are grateful for an equipment grant from the Sun Microsystems, Inc.

  18. Petroleum supply monthly, August 1994

    SciTech Connect

    Not Available

    1994-08-26

    Data presented in the Petroleum Supply Monthly (PSM) describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections: Summary Statistics and Detailed Statistics.

  19. International Oil Supplies and Demands

    SciTech Connect

    Not Available

    1991-09-01

    The eleventh Energy Modeling Forum (EMF) working group met four times over the 1989--90 period to compare alternative perspectives on international oil supplies and demands through 2010 and to discuss how alternative supply and demand trends influence the world's dependence upon Middle Eastern oil. Proprietors of eleven economic models of the world oil market used their respective models to simulate a dozen scenarios using standardized assumptions. From its inception, the study was not designed to focus on the short-run impacts of disruptions on oil markets. Nor did the working group attempt to provide a forecast or just a single view of the likely future path for oil prices. The model results guided the group's thinking about many important longer-run market relationships and helped to identify differences of opinion about future oil supplies, demands, and dependence.

  20. International Oil Supplies and Demands

    SciTech Connect

    Not Available

    1992-04-01

    The eleventh Energy Modeling Forum (EMF) working group met four times over the 1989--1990 period to compare alternative perspectives on international oil supplies and demands through 2010 and to discuss how alternative supply and demand trends influence the world's dependence upon Middle Eastern oil. Proprietors of eleven economic models of the world oil market used their respective models to simulate a dozen scenarios using standardized assumptions. From its inception, the study was not designed to focus on the short-run impacts of disruptions on oil markets. Nor did the working group attempt to provide a forecast or just a single view of the likely future path for oil prices. The model results guided the group's thinking about many important longer-run market relationships and helped to identify differences of opinion about future oil supplies, demands, and dependence.

  1. Petroleum supply monthly, July 1993

    SciTech Connect

    Not Available

    1993-07-29

    Data presented in the Petroleum Supply Monthly (PSM) describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: Petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States.

  2. Leading a supply chain turnaround.

    PubMed

    Slone, Reuben E

    2004-10-01

    Just five years ago, salespeople at Whirlpool were in the habit of referring to their supply chain organization as the "sales disablers." Now the company excels at getting products to the right place at the right time--while managing to keep inventories low. How did that happen? In this first-person account, Reuben Slone, Whirlpool's vice president of Global Supply Chain, describes how he and his colleagues devised the right supply chain strategy, sold it internally, and implemented it. Slone insisted that the right focal point for the strategy was the satisfaction of consumers at the end of the supply chain. Most supply chain initiatives do the opposite: They start with the realities of a company's manufacturing base and proceed from there. Through a series of interviews with trade customers large and small, his team identified 27 different capabilities that drove industry perceptions of Whirlpool's performance. Knowing it was infeasible to aim for world-class performance across all of them, Slone weighed the costs of excelling at each and found the combination of initiatives that would provide overall competitive advantage. A highly disciplined project management office and broad training in project management were key to keeping work on budget and on benefit. Slone set an intense pace--three "releases" of new capabilities every month--that the group maintains to this day. Lest this seem like a technology story, however, Slone insists it is just as much a "talent renaissance." People are proud today to be part of Whirlpool's supply chain organization, and its new generation of talent will give the company a competitive advantage for years to come. PMID:15559580

  3. US energy consumption and supply

    NASA Astrophysics Data System (ADS)

    Vanatta, C. M.

    1981-01-01

    Energy consumption and cost in 1978 and 1979 are discussed with emphasis on the effect of imported oil on the economy of the United States. Some of the international aspects of energy supply are described, and actions to meet the probability of a cutoff of oil imports from the Persian Gulf area are suggested. Short and long range strategies for ensuring energy self sufficiency are discussed. A rationale for major, long range dependence on fission and fusion power is given, and the possible advantages of a nearly all electric energy system are mentioned. Projection of energy consumption and supply to the year 2020 based upon economic and demographic models is discussed.

  4. Air supply distributor for fireplaces

    SciTech Connect

    Eberhardt, H.A.

    1984-09-18

    An air supply distributor for fireplaces having an opening in the hearth for the supply of relatively cold air is used in combination with means, such as a log holder or grate, for supporting combustible products and comprises a pair of side walls and a top cover. The distributor is adapted to be positioned under the log holder or grate to overlie the hearth opening so that relatively cold air passing through the hearth opening is directed toward the front opening of the fireplace from which it passes to the fire for supporting combustion thereof thereby minimizing the amount of air drawn from the room.

  5. Petroleum supply monthly, January 1994

    SciTech Connect

    Not Available

    1994-01-01

    Data presented describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States. The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States.

  6. Level structure and reflection asymmetric shape in sup 223 Ac

    SciTech Connect

    Sheline, R.K.; Liang, C.F.; Paris, P. )

    1990-07-20

    Mass separated sources of {sup 227}Pa (separated as PaF{sub 4}{sup +} ions) were used to study the level structure of {sup 223}Ac following alpha decay. The levels in {sup 223}Ac are interpreted as K = 5/2{sup {plus minus}} parity doublet bands which occur naturally in reflection asymmetric models and the multiphonon octupole model. The anomalous structure of the K = 3/2{sup {minus}} band is explained in terms of Coriolis coupling. The low lying parity doublet bands in {sup 223}Ac, {sup 225}Ac, and {sup 227}Ac are compared and contrasted.

  7. Single transmission line data acquisition system

    DOEpatents

    Fasching, George E.

    1984-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensors monitor specific process variables and transmit measurement values over the single transmission line to a master station when addressed by the master station. Power for all remote stations (up to 980) is provided by driving the line with constant voltage supplied from the master station and automatically maintained independent of the number of remote stations directly connected to the line. The transmission line can be an RG-62 coaxial cable with lengths up to about 10,000 feet with branches up to 500 feet. The remote stations can be attached randomly along the line. The remote stations can be scanned at rates up to 980 channels/second.

  8. RHIC AC DIPOLE DESIGN AND CONSTRUCTION.

    SciTech Connect

    BAI,M.; METH,M.; PAI,C.; PARKER,B.; PEGGS,S.; ROSER,T.; SANDERS,R.; TRBOJEVIC,D.; ZALTSMAN,A.

    2001-06-18

    Two ac dipoles with vertical and horizontal magnetic field have been proposed at RHIC for applications in linear and non-linear beam dynamics and spin manipulations. A magnetic field amplitude of 380 Gm is required to produce a coherent oscillation of 5 times the rms beam size at the top energy. We take the ac dipole frequency to be 1.0% of the revolution frequency away from the betatron frequency. To achieve the strong magnetic field with minimum power loss, an air-core magnet with two seven turn winding of low loss Litz wire resonating at 64 kHz is designed. The system is also designed to allow one to connect the two magnet winding in series to resonate at 37 kHz for the spin manipulation. Measurements of a half length prototype magnet are also presented.

  9. Initial Implementation Strategy for Drizzle with ACS

    NASA Astrophysics Data System (ADS)

    Sparks, W. B.; Hack, W.; Hook, R. N.

    2001-04-01

    In order to provide geometric correction for single pointing ACS images, and to provide geometric correction together with simple image combination for associations of ACS images, we describe plans to implement the "drizzle" code by means of a python wrapper, and to use this wrapper in calacs. The initial strategy will endeavour to be robust and scientifically accurate, although not necessarily optimal. An upgrade path is outlined which could lead to significantly improved processing, involving an iterative pass through the data. The tools will be available stand-alone, offering a greater degree of flexibility than in pipeline implementation. The output product will be a multiple extension fits file containing the data (units counts per second), a weight image and a context image. The latter are provided by the drizzle program and are related to the variance and data quality arrays respectively.

  10. Energy storage in remote area power supply (RAPS) systems

    NASA Astrophysics Data System (ADS)

    Moseley, Patrick T.

    Preliminary cost analyses indicate that hybrid RAPS systems are more economically attractive as a means to provide electricity to remote villages than are alternatives such as 24 h diesel generation. A hybrid remote area power supply (RAPS) system is being deployed to provide 24 h electricity to villages in the Amazon region of Peru. The RAPS system consists of modules designed to provide 150 kWh per day of utility grade ac electricity over a 24 h period. Each module contains a diesel generator, battery bank using heavy-duty 2 V VRLA gelled electrolyte batteries, a battery charger, a photovoltaic array and an inverter. Despite early difficulties, the system in the first village has now commenced operation and the promise of RAPS schemes as a means for providing sustainable remote electrification appears to be bright.

  11. THE ACS NEARBY GALAXY SURVEY TREASURY

    SciTech Connect

    Dalcanton, Julianne J.; Williams, Benjamin F.; Rosema, Keith; Gogarten, Stephanie M.; Christensen, Charlotte; Gilbert, Karoline; Hodge, Paul; Seth, Anil C.; Dolphin, Andrew; Holtzman, Jon; Skillman, Evan D.; Weisz, Daniel; Cole, Andrew; Girardi, Leo; Karachentsev, Igor D.; Olsen, Knut; Freeman, Ken; Gallart, Carme; De Jong, Roelof S. E-mail: ben@astro.washington.edu E-mail: stephanie@astro.washington.edu E-mail: fabio@astro.washington.edu E-mail: aseth@cfa.harvard.edu

    2009-07-15

    The ACS Nearby Galaxy Survey Treasury (ANGST) is a systematic survey to establish a legacy of uniform multi-color photometry of resolved stars for a volume-limited sample of nearby galaxies (D < 4 Mpc). The survey volume encompasses 69 galaxies in diverse environments, including close pairs, small and large groups, filaments, and truly isolated regions. The galaxies include a nearly complete range of morphological types spanning a factor of {approx}10{sup 4} in luminosity and star formation rate. The survey data consist of images taken with the Advanced Camera for Surveys (ACS) on the Hubble Space Telescope (HST), supplemented with archival data and new Wide Field Planetary Camera 2 (WFPC2) imaging taken after the failure of ACS. Survey images include wide field tilings covering the full radial extent of each galaxy, and single deep pointings in uncrowded regions of the most massive galaxies in the volume. The new wide field imaging in ANGST reaches median 50% completenesses of m {sub F475W} = 28.0 mag, m {sub F606W} = 27.3 mag, and m {sub F814W} = 27.3 mag, several magnitudes below the tip of the red giant branch (TRGB). The deep fields reach magnitudes sufficient to fully resolve the structure in the red clump. The resulting photometric catalogs are publicly accessible and contain over 34 million photometric measurements of >14 million stars. In this paper we present the details of the sample selection, imaging, data reduction, and the resulting photometric catalogs, along with an analysis of the photometric uncertainties (systematic and random), for both ACS and WFPC2 imaging. We also present uniformly derived relative distances measured from the apparent magnitude of the TRGB.

  12. Large aperture ac interferometer for optical testing.

    PubMed

    Moore, D T; Murray, R; Neves, F B

    1978-12-15

    A 20-cm clear aperture modified Twyman-Green interferometer is described. The system measures phase with an AC technique called phase-lock interferometry while scanning the aperture with a dual galvanometer scanning system. Position information and phase are stored in a minicomputer with disk storage. This information is manipulated with associated software, and the wavefront deformation due to a test component is graphically displayed in perspective and contour on a CRT terminal. PMID:20208642

  13. Highlights of the Dallas ACS Meeting

    NASA Astrophysics Data System (ADS)

    Wildeman, Thomas R.; Freilich, Mark; Kelter, Paul B.

    1998-06-01

    Without a doubt, a primary feature of the 1998 Spring National Meeting in Dallas was the High School Program, which was organized by George Hague, and the impact that the Texas teachers had on other participants. Over 150 teachers registered for the meeting and participated in the program. Their organizational skills were used to reinstitute the High School/College Interface Luncheon. (The High School/College Interface Luncheon will also be held at the Fall ACS Meeting in Boston.)

  14. Graphs for Isotopes of 89-Ac (Actinium)

    NASA Astrophysics Data System (ADS)

    Sukhoruchkin, S. I.; Soroko, Z. N.

    This document is part of the Supplement containing the complete sets of data of Subvolume B `Nuclei with Z = 55 - 100' of Volume 22 `Nuclear Binding Energies and Atomic Masses' of Landolt-Börnstein - Group I `Elementary Particles, Nuclei and Atoms', and additionally including data for nuclei with Z = 101 - 130. It provides a graphic representation of nucleon separation energies and residual interaction parameters for isotopes of the chemical element 89-Ac (Actinium, atomic number Z = 89).

  15. [A novel Fe/AC desulphurizer at low temperature].

    PubMed

    Ma, J; Liu, S; Liu, Z; Zhu, Z; An, M; Yan, B

    2001-11-01

    Activated coke was used to support Fe2O3(Fe/AC) for flue gas SO2 removal. Reaction conditions on DeSOx activity were investigated. The results show that Fe/AC had higher activity than AC or Fe2O3 at temperature of 120 degrees C-250 degrees C. H2SO4 and Fe2(SO4)3 were formed after Fe/AC sorbed SO2, H2O and O2 increased the amount of SO2 adsorption. Fe/AC derived from AC of higher BET surface area had higher DeSOx activity. Fe/AC was suitable to be used at GHSV below 800 L/(kg.h). PMID:11855176

  16. Spectroscopic Observations and Analysis of the Unusual Type Ia SN1999ac

    SciTech Connect

    Garavini, G.; Aldering, G.; Amadon, A.; Amanullah, R.; Astier,P.; Balland, C.; Blanc, G.; Conley, A.; Dahlen, T.; Deustua, S.E.; Ellis,R.; Fabbro, S.; Fadeyev, V.; Fan, X.; Folatelli, G.; Frye, B.; Gates,E.L.; Gibbons, R.; Goldhaber, G.; Goldman, B.; Goobar, A.; Groom, D.E.; Haissinski, J.; Hardin, D.; Hook, I.; Howell, D.A.; Kent, S.; Kim, A.G.; Knop, R.A.; Kowalski, M.; Kuznetsova, N.; Lee, B.C.; Lidman, C.; Mendez,J.; Miller, G.J.; Moniez, M.; Mouchet, M.; Mourao, A.; Newberg, H.; Nobili, S.; Nugent, P.E.; Pain, R.; Perdereau, O.; Perlmutter, S.; Quimby, R.; Regnault, N.; Rich, J.; Richards, G.T.; Ruiz-Lapuente, P.; Schaefer, B.E.; Schahmaneche, K.; Smith, E.; Spadafora, A.L.; Stanishev,V.; Thomas, R.C.; Walton, N.A.; Wang, L.; Wood-Vasey, W.M.

    2005-07-12

    The authors present optical spectra of the peculiar Type Ia supernova (SN Ia) 1999ac. The data extend from -15 to +42 days with respect to B-band maximum and reveal an event that is unusual in several respects. prior to B-band maximum, the spectra resemble those of SN 1999aa, a slowly declining event, but possess stronger Si II and Ca II signatures (more characteristic of a spectroscopically normal SN). Spectra after B-band maximum appear more normal. The expansion velocities inferred from the Iron lines appear to be lower than average; whereas, the expansion velocity inferred from Calcium H and K are higher than average. The expansion velocities inferred from the Iron lines appear to be lower than average; whereas, the expansion velocity inferred from Calcium H and K are higher than average. The expansion velocities inferred from Si II are among the slowest ever observed, though SN 1999ac is not particularly dim. The analysis of the parameters v{sub 10}(Si II), R(Si II), v, and {Delta}m{sub 15} further underlines the unique characteristics of SN 1999ac. They find convincing evidence of C II {lambda}6580 in the day -15 spectrum with ejection velocity v > 16,000 km s{sup -1}, but this signature disappears by day -9. This rapid evolution at early times highlights the importance of extremely early-time spectroscopy.

  17. Magnetically switched power supply system for lasers

    NASA Technical Reports Server (NTRS)

    Pacala, Thomas J. (Inventor)

    1987-01-01

    A laser power supply system is described in which separate pulses are utilized to avalanche ionize the gas within the laser and then produce a sustained discharge to cause the gas to emit light energy. A pulsed voltage source is used to charge a storage device such as a distributed capacitance. A transmission line or other suitable electrical conductor connects the storage device to the laser. A saturable inductor switch is coupled in the transmission line for containing the energy within the storage device until the voltage level across the storage device reaches a predetermined level, which level is less than that required to avalanche ionize the gas. An avalanche ionization pulse generating circuit is coupled to the laser for generating a high voltage pulse of sufficient amplitude to avalanche ionize the laser gas. Once the laser gas is avalanche ionized, the energy within the storage device is discharged through the saturable inductor switch into the laser to provide the sustained discharge. The avalanche ionization generating circuit may include a separate voltage source which is connected across the laser or may be in the form of a voltage multiplier circuit connected between the storage device and the laser.

  18. Development of software to improve AC power quality on large spacecraft

    NASA Technical Reports Server (NTRS)

    Kraft, L. Alan

    1991-01-01

    To insure the reliability of a 20 kHz, AC power system on spacecraft, it is essential to analyze its behavior under many adverse operating conditions. Some of these conditions include overloads, short circuits, switching surges, and harmonic distortions. Harmonic distortions can cause malfunctions in equipment that the power system is supplying, and during extreme distortions such as voltage resonance, it can cause equipment and insulation failures due to the extreme peak voltages. HARMFLO, a power flow computer program, which was capable of analyzing harmonic conditions on three phase, balanced, 60 Hz, AC power systems, was modified to analyze single phase, 20 kHz, AC power systems. Since almost all of the equipment used on spacecraft power systems is electrically different from equipment used on terrestrial power systems, it was also necessary to develop mathematical models for the equipment to be used on the spacecraft. The results are that (1) the harmonic power now has a model of a single phase, voltage controlled, full wave rectifier; and (2) HARMFLO was ported to the SUN workstation platform.

  19. Art Supply Inventors. Children's Art Diary.

    ERIC Educational Resources Information Center

    Szekely, George

    2001-01-01

    Discusses types of art materials that children enjoy using in their artworks. Explores the art materials such as tasty art supplies, such as candy; peeled supplies, such as pencil shavings; sticky art supplies, such as Band-Aids; and fast-food supplies, such as forks and spoons. (CMK)

  20. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless...

  1. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless...

  2. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless...

  3. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless...

  4. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless...

  5. 10 CFR 218.11 - Supply orders.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... ENERGY OIL STANDBY MANDATORY INTERNATIONAL OIL ALLOCATION Supply Orders § 218.11 Supply orders. (a) A supply order shall require that the firm to which it is issued take actions specified therein relating to..., producing, storing, transporting or refining oil. A supply order shall include a concise statement of...

  6. 10 CFR 218.11 - Supply orders.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... ENERGY OIL STANDBY MANDATORY INTERNATIONAL OIL ALLOCATION Supply Orders § 218.11 Supply orders. (a) A supply order shall require that the firm to which it is issued take actions specified therein relating to..., producing, storing, transporting or refining oil. A supply order shall include a concise statement of...

  7. 10 CFR 218.11 - Supply orders.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... ENERGY OIL STANDBY MANDATORY INTERNATIONAL OIL ALLOCATION Supply Orders § 218.11 Supply orders. (a) A supply order shall require that the firm to which it is issued take actions specified therein relating to..., producing, storing, transporting or refining oil. A supply order shall include a concise statement of...

  8. 10 CFR 218.11 - Supply orders.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... ENERGY OIL STANDBY MANDATORY INTERNATIONAL OIL ALLOCATION Supply Orders § 218.11 Supply orders. (a) A... supplying the stated volume of oil to a specified recipient including, but not limited to, distributing, producing, storing, transporting or refining oil. A supply order shall include a concise statement of...

  9. 10 CFR 218.11 - Supply orders.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... ENERGY OIL STANDBY MANDATORY INTERNATIONAL OIL ALLOCATION Supply Orders § 218.11 Supply orders. (a) A... supplying the stated volume of oil to a specified recipient including, but not limited to, distributing, producing, storing, transporting or refining oil. A supply order shall include a concise statement of...

  10. Supply Curves of Conserved Energy

    SciTech Connect

    Meier, Alan Kevin

    1982-05-01

    Supply curves of conserved energy provide an accounting framework that expresses the potential for energy conservation. The economic worthiness of a conservation measure is expressed in terms of the cost of conserved energy, and a measure is considered economical when the cost of conserved energy is less than the price of the energy it replaces. A supply curve of conserved energy is independent of energy prices; however, the economical reserves of conserved energy will depend on energy prices. Double-counting of energy savings and error propagation are common problems when estimating conservation potentials, but supply curves minimize these difficulties and make their consequences predictable. The sensitivity of the cost of conserved energy is examined, as are variations in the optimal investment strategy in response to changes in inputs. Guidelines are presented for predicting the consequences of such changes. The conservation supply curve concept can be applied to peak power, water, pollution, and other markets where consumers demand a service rather than a particular good.

  11. Water Supply Infrastructure System Surety

    SciTech Connect

    EKMAN,MARK E.; ISBELL,DARYL

    2000-01-06

    The executive branch of the United States government has acknowledged and identified threats to the water supply infrastructure of the United States. These threats include contamination of the water supply, aging infrastructure components, and malicious attack. Government recognition of the importance of providing safe, secure, and reliable water supplies has a historical precedence in the water works of the ancient Romans, who recognized the same basic threats to their water supply infrastructure the United States acknowledges today. System surety is the philosophy of ''designing for threats, planning for failure, and managing for success'' in system design and implementation. System surety is an alternative to traditional compliance-based approaches to safety, security, and reliability. Four types of surety are recognized: reactive surety; proactive surety, preventative surety; and fundamental, inherent surety. The five steps of the system surety approach can be used to establish the type of surety needed for the water infrastructure and the methods used to realize a sure water infrastructure. The benefit to the water industry of using the system surety approach to infrastructure design and assessment is a proactive approach to safety, security, and reliability for water transmission, treatment, distribution, and wastewater collection and treatment.

  12. The Management of Groundwater Supplies.

    ERIC Educational Resources Information Center

    Hall, P. L.

    1978-01-01

    The manager of a groundwater supply system must be involved in many different disciplines if he or she is to manage the system effectively. In areas in which specialized expertise is necessary, it can be obtained from consultants or government agencies. (BB)

  13. Economic drivers of mineral supply

    USGS Publications Warehouse

    Wagner, Lorie A.; Sullivan, Daniel E.; Sznopek, John L.

    2003-01-01

    The debate over the adequacy of future supplies of mineral resources continues in light of the growing use of mineral-based materials in the United States. According to the U.S. Geological Survey, the quantity of new materials utilized each year has dramatically increased from 161 million tons2 in 1900 to 3.2 billion tons in 2000. Of all the materials used during the 20th century in the United States, more than half were used in the last 25 years. With the Earth?s endowment of natural resources remaining constant, and increased demand for resources, economic theory states that as depletion approaches, prices rise. This study shows that many economic drivers (conditions that create an economic incentive for producers to act in a particular way) such as the impact of globalization, technological improvements, productivity increases, and efficient materials usage are at work simultaneously to impact minerals markets and supply. As a result of these economic drivers, the historical price trend of mineral prices3 in constant dollars has declined as demand has risen. When price is measured by the cost in human effort, the price trend also has been almost steadily downward. Although the United States economy continues its increasing mineral consumption trend, the supply of minerals has been able to keep pace. This study shows that in general supply has grown faster than demand, causing a declining trend in mineral prices.

  14. Development of a hardware-based AC microgrid for AC stability assessment

    NASA Astrophysics Data System (ADS)

    Swanson, Robert R.

    As more power electronic-based devices enable the development of high-bandwidth AC microgrids, the topic of microgrid power distribution stability has become of increased interest. Recently, researchers have proposed a relatively straightforward method to assess the stability of AC systems based upon the time-constants of sources, the net bus capacitance, and the rate limits of sources. In this research, a focus has been to develop a hardware test system to evaluate AC system stability. As a first step, a time domain model of a two converter microgrid was established in which a three phase inverter acts as a power source and an active rectifier serves as an adjustable constant power AC load. The constant power load can be utilized to create rapid power flow transients to the generating system. As a second step, the inverter and active rectifier were designed using a Smart Power Module IGBT for switching and an embedded microcontroller as a processor for algorithm implementation. The inverter and active rectifier were designed to operate simultaneously using a synchronization signal to ensure each respective local controller operates in a common reference frame. Finally, the physical system was created and initial testing performed to validate the hardware functionality as a variable amplitude and variable frequency AC system.

  15. Central line infections - hospitals

    MedlinePlus

    ... infection; CVC - infection; Central venous device - infection; Infection control - central line infection; Nosocomial infection - central line infection; Hospital acquired infection - central line infection; Patient safety - central ...

  16. Supply chain challenges. building relationships.

    PubMed

    Beth, Scott; Burt, David N; Copacino, William; Gopal, Chris; Lee, Hau L; Lynch, Robert Porter; Morris, Sandra

    2003-07-01

    Supply chain management is all about software and systems, right? Put in the best technology, sit back, and watch as your processes run smoothly and the savings roll in? Apparently not. When HBR convened a panel of leading thinkers in the field of supply chain management, technology was not top of mind. People and relationships were the dominant issues of the day. The opportunities and problems created by globalization, for example, are requiring companies to establish relationships with new types of suppliers. The ever-present pressure for speed and cost containment is making it even more important to break down stubbornly high internal barriers and establish more effective cross-functional relationships. The costs of failure have never been higher. The leading supply chain performers are applying new technology, new innovations, and process thinking to far greater advantage than the laggards, reaping tremendous gains in all the variables that affect shareholder value: cost, customer service, asset productivity, and revenue generation. And the gap between the leaders and the losers is growing in almost every industry. This roundtable gathered many of the leading thinkers and doers in the field of supply chain management, including practitioners Scott Beth of Intuit, Sandra Morris of Intel, and Chris Gopal of Unisys. David Burt of the University of San Diego and Stanford's Hau Lee bring the latest research from academia. Accenture's William Copacino and the Warren Company's Robert Porter Lynch offer the consultant's perspectives. Together, they take a wide-ranging view of such topics as developing talent, the role of the chief executive, and the latest technologies, exploring both the tactical and the strategic in the current state of supply chain management. PMID:12858712

  17. Petroleum supply monthly, March 1994

    SciTech Connect

    Not Available

    1994-03-30

    Data presented in the Petroleum Supply Monthly (PSM) describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections: Summary Statistics and Detailed Statistics. The tables and figures in the Summary Statistics section of the PSM present a time series of selected petroleum data on a US level. Most time series include preliminary estimates for one month based on the Weekly Petroleum Supply Reporting System; statistics based on the most recent data from the Monthly Petroleum Supply Reporting System (MPSRS); and statistics published in prior issues of the PSM and PSA. The Detailed Statistics tables of the PSM present statistics for the most current month available as well as year-to-date. In most cases, the statistics are presented for several geographic areas -- the United States (50 States and the District of Columbia), five PAD Districts, and 12 Refining Districts. At the US and PAD District level, the total volume and the daily rate of activities are presented. The statistics are developed from monthly survey forms submitted by respondents to the EIA and from data provided from other sources.

  18. Petroleum supply monthly, June 1993

    SciTech Connect

    Not Available

    1993-06-28

    Data presented in the Petroleum Supply Monthly (PSM) describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections: Summary Statistics and Detailed Statistics. The tables and figures ih the Summary Statistics section of the PSM present a time series of selected petroleum data on a US level. Most time series include preliminary estimates for one month based on the Weekly Petroleum Supply Reporting System; statistics based on the most recent data from the Monthly Petroleum Supply Reporting System (MPSRS); and statistics published in prior issues of the PSM and PSA. The Detailed Statistics tables of the PSM present statistics for the most current month available as well as year-to-date. In most cases, the statistics are presented for several geographic areas - - the United States (50 States and the District of Columbia), five PAD Districts, and 12 Refining Districts. At the US and PAD District level, the total volume and the daily rate of activities are presented. The statistics are developed from monthly survey forms submitted by respondents to the EIA and from data provided firom other sources.

  19. Development of the PEFP's beam line BPM

    NASA Astrophysics Data System (ADS)

    Ryu, Jin-Yeong; Kwon, Hyeok-Jung; Jang, Ji-Ho; Kim, Han-Sung; Seol, Kyung-Tae; Cho, Yong-Sub

    2013-01-01

    The Proton Engineering Frontier Project (PEFP) has 20-MeV and 100-MeV beam lines to supply proton beams to users. A stripline-type Beam Position Monitor (BPM) was designed and fabricated in order to measure the beam's position in the beam line. The RF properties of the BPM were measured and compared with the simulation. After the sensitivity of the BPM at a test stand had been obtained, we performed a beam test in a test beam line of the PEFP 20-MeV proton linac.

  20. Deletion of the AcMNPV core gene ac109 results in budded virions that are non-infectious

    SciTech Connect

    Fang Minggang; Nie, Yingchao; Theilmann, David A.

    2009-06-20

    Autographa californica multiple nucleopolyhedrovirus (AcMNPV) ac109 is a core gene and its function in the virus life cycle is unknown. To determine its role in the baculovirus life cycle, we used the AcMNPV bacmid system to generate an ac109 deletion virus (vAc{sup 109KO}). Fluorescence and light microscopy showed that transfection of vAc{sup 109KO} results in a single-cell infection phenotype. Viral DNA replication is unaffected and the development of occlusion bodies in vAc{sup 109KO}-transfected cells evidenced progression to the very late phases of viral infection. Western blot and confocal immunofluorescence analysis showed that AC109 is expressed in the cytoplasm and nucleus throughout infection. In addition, AC109 is a structural protein as it was detected in both budded virus (BV) and occlusion derived virus in both the envelope and nucleocapsid fractions. Titration assays by qPCR and TCID{sub 50} showed that vAc{sup 109KO} produced BV but the virions are non-infectious. The vAc{sup 109KO} BV were indistinguishable from the BV of repaired and wild type control viruses as determined by negative staining and electron microscopy.

  1. SPEAR3 DC MAGNET POWER SUPPLIES - AN OVERVIEW

    SciTech Connect

    de Lira, A

    2004-03-25

    The Stanford Synchrotron Radiation Laboratory (SSRL) has successfully commissioned SPEAR 3, its newly upgraded 3-GeV synchrotron light source. First stored beam occurred December 15, 2003. This paper presents an overview and descriptions of the DC magnet power supplies. These consist of tightly-regulated ({le} 10 ppm) current sources ranging in output from 30 A to 800 A and output power ranging from a few watts to almost 1.0 MW. A total of 226 magnet power supplies are in successful operation. The SPEAR 3 upgrade performance and reliability requirements mandated new power supplies for both the SPEAR 3 storage ring, and for the booster-to-SPEAR 3 (BTS) transport line. A large variety of precise, highly stable current power supplies were needed to fill the diverse magnet needs. Also described are outside procurement aspects, in-house construction, installation, testing, performance and operation of the power supplies. During field testing, special emphasis was made to ensure a critically damped response on the current loop. Frequency spectra measurements were made for reference and future diagnostics.

  2. A study of electric power transmission lines for use on the lunar surface

    SciTech Connect

    Gordon, L.B.; Gaustad, K.L. )

    1991-01-10

    Analytical models have been developed to study the operating characteristics of electrical transmission lines for use on the lunar surface. Important design considerations for a transmission line operating on the lunar surface are mass, temperature, and efficiency. Transmission line parameters which impact these considerations include voltage, power loss, and waveform. The electrical and thermal models developed are used to calculate transmission line mass, size, and temperature as a function of voltage, geometry, waveform, location, and efficiency. The analyses include AC and DC for above and below ground operation. Geometries studied include a vacuum-insulated, two-wire transmission line and a solid-dielectric insulated, coaxial transmission line. A brief discussion of design considerations and the models developed is followed by results for parameter studies for both DC and AC transmission lines.

  3. The Influence of Primary Care and Hospital Supply on Ambulatory Care–Sensitive Hospitalizations Among Adults in Brazil, 1999–2007

    PubMed Central

    de Oliveira, Veneza B.; Turci, Maria A.; Guanais, Frederico C.; Bonolo, Palmira F.; Lima-Costa, Maria F.

    2011-01-01

    Objectives. We assessed the influence of changes in primary care and hospital supply on rates of ambulatory care–sensitive (ACS) hospitalizations among adults in Brazil. Methods. We aggregated data on nearly 60 million public sector hospitalizations between 1999 and 2007 to Brazil's 558 microregions. We modeled adult ACS hospitalization rates as a function of area-level socioeconomic factors, health services supply, Family Health Program (FHP) availability, and health needs by using dynamic panel estimation techniques to control for endogenous explanatory variables. Results. The ACS hospitalization rates declined by more than 5% annually. When we controlled for other factors, FHP availability was associated with lower ACS hospitalization rates, whereas private or nonprofit hospital beds were associated with higher rates. Areas with highest predicted ACS hospitalization rates were those with the highest private or nonprofit hospital bed supply and with low (< 25%) FHP coverage. The lowest predicted rates were seen for areas with high (> 75%) FHP coverage and very few private or nonprofit hospital beds. Conclusions. These results highlight the contribution of the FHP to improved health system performance and reflect the complexity of the health reform processes under way in Brazil. PMID:21330584

  4. New definitions of pointing stability - ac and dc effects. [constant and time-dependent pointing error effects on image sensor performance

    NASA Technical Reports Server (NTRS)

    Lucke, Robert L.; Sirlin, Samuel W.; San Martin, A. M.

    1992-01-01

    For most imaging sensors, a constant (dc) pointing error is unimportant (unless large), but time-dependent (ac) errors degrade performance by either distorting or smearing the image. When properly quantified, the separation of the root-mean-square effects of random line-of-sight motions into dc and ac components can be used to obtain the minimum necessary line-of-sight stability specifications. The relation between stability requirements and sensor resolution is discussed, with a view to improving communication between the data analyst and the control systems engineer.

  5. An Ac/Ds-mediated gene trap system for functional genomics in barley

    PubMed Central

    Lazarow, Katina; Lütticke, Stephanie

    2009-01-01

    Background Gene trapping is a powerful tool for gene discovery and functional genomics in both animals and plants. Upon insertion of the gene trap construct into an expressed gene, splice donor and acceptor sites facilitate the generation of transcriptional fusions between the flanking sequence and the reporter. Consequently, detection of reporter gene expression allows the identification of genes based on their expression pattern. Up to now rice is the only cereal crop for which gene trap approaches exist. In this study we describe a gene trap system in barley (Hordeum vulgare L.) based on the maize transposable elements Ac/Ds. Results We generated gene trap barley lines by crossing Ac transposase expressing plants with multiple independent transformants carrying the Ds based gene trap construct GTDsB. Upstream of the β-Glucuronidase start codon GTDsB carries splice donor and acceptor sites optimized for monocotyledonous plants. DNA blot analysis revealed GTDsB transposition frequencies of 11% and 26% in the F1 and F2 generation of gene trap lines and perpetuation of transposition activity in later generations. Furthermore, analysis of sequences flanking transposed GTDsB elements evidenced preferential insertion into expressed regions of the barley genome. We screened leaves, nodes, immature florets, pollinated florets, immature grains and seedlings of F2 plants and detected GUS expression in 51% (72/141) of the plants. Thus, reporter gene expression was found in 24 of the 28 F1 lines tested and in progeny of all GTDsB parental lines. Conclusion Due to the frequent transposition of GTDsB and the efficient expression of the GUS reporter gene, we conclude that this Ac/Ds-based gene trap system is an applicable approach for gene discovery in barley. The successful introduction of a gene trap construct optimized for monocots in barley contributes a novel functional genomics tool for this cereal crop. PMID:19178688

  6. 77 FR 53174 - Certain Lined Paper Products From Indonesia: Revocation of Antidumping and Countervailing Duty...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-31

    ..., 76 FR 45778 (August 1, 2011) and Certain Lined Paper School Supplies From China, India, and Indonesia... Republic of China, 76 FR 76123 (December 6, 2011) and Certain Lined Paper Products From Indonesia: Final... Paper School Supplies From China, India, and Indonesia, 77 FR 51570 (August 24, 2012). See also...

  7. Smart Power Supply for Battery-Powered Systems

    NASA Technical Reports Server (NTRS)

    Krasowski, Michael J.; Greer, Lawrence; Prokop, Norman F.; Flatico, Joseph M.

    2010-01-01

    differing power needs, this supply also has a secondary power bus, which can be programmed a priori or on-the-fly to boost the primary battery voltage level from 24 to 50 V to accommodate various loads as they are brought on line. Through voltage and current monitoring, the device can also shield the charging source from overloads, keep it within safe operating modes, and can meter available power to the application and maintain safe operations.

  8. Cry2Ab tolerance response of Helicoverpa armigera (Lepidoptera: Noctuidae) populations from CrylAc cotton planting region.

    PubMed

    Gao, Yulin; Wu, Kongming; Gould, Fred; Shen, Zhicheng

    2009-06-01

    Helicoverpa armigera (Hübner) (Lepidoptera: Noctuidae) is an important lepidopteran pest of cotton, Gossypium hirsutum L., in Asia. Transgenic cotton expressing the cry1Ac gene from Bacillus thuringiensis (Bt) has been widely planted for control of this pest. For managing the potential risk from resistance evolution in this pest, a new transgenic Bt cotton containing cry1Ac and cry2Ab genes (gene pyramided strategy) was designed as a successor of cry1Ac cotton. This article reports on levels of Cry2Ab tolerance in H. armigera populations from CrylAc cotton planting region in China based on bioassays of F1 and F2 offspring of isofemale lines. In total, 572 isofemale families of H. armigera from Xiajin County of Shandong Province (an intensive Bt cotton-planting area) and 124 families from Anci County of Hebei Province [a multiple-crop system, including corn (Zea mays L.), soybean (Gycine max (L.) Merr., peanut (Arachis spp.), and Bt cotton] were screened with both Cry1Ac- and Cry2Ab-containing diets in 2008. The bioassays results indicated that relative average development rates (RADR) of F1 full-sib families from field-collected female moths on Cry1Ac- and Cry2Ab-containing diet were positively correlated. The same correlation was found in the F2 generation, indicating cross-tolerance between Cry1Ac and Cry2Ab in field populations of H. armigera in Yellow River cotton-farming region of China. This cross-tolerance must be considered in evaluating the utility of pyramiding Bt genes in cotton for delaying evolution of resistance. PMID:19610441

  9. Results of experimental studies of the gas-dynamic behavior of airflow in the circulation line of the air condenser of steam-turbine plants

    NASA Astrophysics Data System (ADS)

    Fedorov, V. A.; Mil'man, O. O.; Gribin, V. G.; Anan'ev, P. A.

    2014-12-01

    The results of experimental studies and a physical model of the three-dimensional flow of cooling air in the circulation line (CL) of a dummy air condenser (AC) incorporating a fan, heat-exchange modules, a shell, and other auxiliary components are analyzed. The local air velocity fields determined experimentally at the AC CL inlet and at the fan diffuser outlet are presented. The guidelines for determining the head-capacity characteristics of the airflow through the AC CL are proposed.

  10. Spatially Characterizing Effective Timber Supply

    NASA Technical Reports Server (NTRS)

    Berry, J. K.; Sailor, J.

    1982-01-01

    The structure of a computer-oriented cartographic model for assessing roundwood supply for generation of base load electricity is discussed. The model provides an analytical procedure for coupling spatial information of harvesting economics and owner willingness to sell stumpages. Supply is characterized in terms of standing timber; of accessibility considering various harvesting and hauling factors; and of availability as affected by ownership and residential patterns. Factors governing accessibility to timber include effective harvesting distance to haulic roads as modified by barriers and slopes. Haul distance is expressed in units that take into account the relative ease of travel along various road types to a central processing facility. Areas of accessible timber are grouped into spatial units, termed 'timbersheds', of common access to particular haul road segments that belong to unique 'transport zones'. Timber availability considerations include size of ownership parcels, housing density and excluded areas. The analysis techniques are demonstrated for a cartographic data base in western Massachusetts.

  11. 1992 Conversion Resources Supply Document

    SciTech Connect

    Not Available

    1992-03-01

    In recent years conservation of electric power has become an integral part of utility planning. The 1980 Pacific Northwest Electric Power Planning and Conservation Act (Northwest Power Act) requires that the region consider conservation potential in planning acquisitions of resources to meet load growth. The Bonneville Power Administration (BPA) developed its first estimates of conservation potential in 1982. Since that time BPA has updated its conservation supply analyses as a part of its Resource Program and other planning efforts. Major updates were published in 1985 and in January 1990. This 1992 document presents updated supply curves, which are estimates of the savings potential over time (cumulative savings) at different cost levels of energy conservation measures (ECMs). ECMs are devices, pieces of equipment, or actions that increase the efficiency of electricity use and reduce the amount of electricity used by end-use equipment.

  12. High voltage DC power supply

    DOEpatents

    Droege, T.F.

    1989-12-19

    A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

  13. High voltage DC power supply

    DOEpatents

    Droege, Thomas F.

    1989-01-01

    A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

  14. Petroluem Supply Monthly, May 1993

    SciTech Connect

    Not Available

    1993-06-04

    Data presented in the PSM describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 States and the District of Columbia). The reporting universe includes those petroleum sectors in primary supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States. Data presented in the PSM are divided into two sections: Summary Statistics and Detailed Statistics.

  15. Reprivatizing pharmaceutical supplies in Africa.

    PubMed

    Turshen, M

    2001-01-01

    Perhaps no part of the health system is as imperiled by neoliberal economic reforms as the public drug sector. The national bill for pharmaceuticals can claim one-third of a developing country's annual health budget. This article describes the essential drugs program created by WHO in the 1980s to protect financially reduced ministries of health from the high prices charged by multinational pharmaceutical companies. It describes the backlash from the World Bank and UNICEF, which launched the Bamako Initiative and other community financing schemes and revolving drug plans in which individuals, families or community groups buy drugs above the wholesale purchase price; clinics use the proceeds to maintain drug supplies and subsidize other health services. When this plan failed, the Bank proposed outright privatization of drug purchase and supply, returning power to the multinational suppliers. The article ends with a consideration of patents and the new intellectual property rights as they pertain to pharmaceutical production in Africa. PMID:11469153

  16. Petroleum Supply Monthly, July 1990

    SciTech Connect

    Not Available

    1990-09-28

    Data presented in the PSM describe the supply and disposition of petroleum products in the United States and major US geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States (50 states and the District of Columbia). The reporting universe includes those petroleum sectors in Primary Supply. Included are: petroleum refiners, motor gasoline blenders, operators of natural gas processing plants and fractionators, inter-PAD transporters, importers, and major inventory holders of petroleum products and crude oil. When aggregated, the data reported by these sectors approximately represent the consumption of petroleum products in the United States.

  17. Replenishable food supply on Mars

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The design team's present objective is to design a facility which will provide an environment to grow plants on the surface of Mars for a continuous supply of food for a ten-man crew. The main focus of the project is the design of a greenhouse. Concentration of the current design effort is on the outer structure, internal layout, and construction methods. The project was conducted by undergraduate students at Prairie View A&M University during Fall 1989 and Spring 1990.

  18. Dietary mineral supplies in Africa

    PubMed Central

    Joy, Edward J M; Ander, E Louise; Young, Scott D; Black, Colin R; Watts, Michael J; Chilimba, Allan D C; Chilima, Benson; Siyame, Edwin W P; Kalimbira, Alexander A; Hurst, Rachel; Fairweather-Tait, Susan J; Stein, Alexander J; Gibson, Rosalind S; White, Philip J; Broadley, Martin R

    2014-01-01

    Dietary micronutrient deficiencies (MNDs) are widespread, yet their prevalence can be difficult to assess. Here, we estimate MND risks due to inadequate intakes for seven minerals in Africa using food supply and composition data, and consider the potential of food-based and agricultural interventions. Food Balance Sheets (FBSs) for 46 countries were integrated with food composition data to estimate per capita supply of calcium (Ca), copper (Cu), iron (Fe), iodine (I), magnesium (Mg), selenium (Se) and zinc (Zn), and also phytate. Deficiency risks were quantified using an estimated average requirement (EAR) ‘cut-point’ approach. Deficiency risks are highest for Ca (54% of the population), followed by Zn (40%), Se (28%) and I (19%, after accounting for iodized salt consumption). The risk of Cu (1%) and Mg (<1%) deficiency are low. Deficiency risks are generally lower in the north and west of Africa. Multiple MND risks are high in many countries. The population-weighted mean phytate supply is 2770 mg capita−1 day−1. Deficiency risks for Fe are lower than expected (5%). However, ‘cut-point’ approaches for Fe are sensitive to assumptions regarding requirements; e.g. estimates of Fe deficiency risks are 43% under very low bioavailability scenarios consistent with high-phytate, low-animal protein diets. Fertilization and breeding strategies could greatly reduce certain MNDs. For example, meeting harvestplus breeding targets for Zn would reduce dietary Zn deficiency risk by 90% based on supply data. Dietary diversification or direct fortification is likely to be needed to address Ca deficiency risks. PMID:24524331

  19. Supply Current Diagnosis in VLSI

    NASA Technical Reports Server (NTRS)

    Frenzel, J. F.; Marinos, P. N.

    1990-01-01

    This paper presents a technique based upon the power supply current signature (cd) which allows for the testing of mixed-signal systems, in situ. Through experiments with a microprocessor, the cd is shown to contain important information concerning the operational status of the system which may be easily extracted using approaches based on statistical signal detection theory. The fault-detection performance of these techniques is compared to that achieved through auto-regressive modeling of the cd.

  20. Arylhydrocarbon receptor (AhR) activation in airway epithelial cells induces MUC5AC via reactive oxygen species (ROS) production.

    PubMed

    Chiba, Takahito; Uchi, Hiroshi; Tsuji, Gaku; Gondo, Hisaki; Moroi, Yoichi; Furue, Masutaka

    2011-02-01

    The dioxins and dioxin-like compounds in cigarette smoke regulate various immunological responses via the arylhydrocarbon receptor (AhR). These environmental toxicants are known to cause bronchitis, asthma, chronic obstructive pulmonary disease (COPD), and lung cancer. Recent studies have demonstrated that AhR activation upregulates the expression of mucin 5AC, oligomeric mucus/gel-forming (MUC5AC) in the airway epithelial cell line. However, the mechanism for the production of mucin has not been clarified. In this study, we investigated the role and pathway of AhR in airway epithelial cells by using selective agonists and antagonists. After stimulation with or without benzopyrene (B[a]P), an AhR agonist, MUC5AC expression was measured by real-time RT-PCR. The mechanism of AhR-induced MUC5AC expression in airway epithelial cells was studied in terms of the production of cytokine and reactive oxygen species (ROS). Treatment with B[a]P increased ROS generation in NCI-H₂₉₂ cells. Furthermore, B[a]P-induced MUC5AC upregulation and mucin production were inhibited by AhR siRNA or the use of an antioxidative agent. These results suggest that the AhR-induced increase of mucin production is partially mediated by ROS generation. An antioxidant therapy approach may help to cure AhR-induced mucus hypersecretory diseases. PMID:20709182

  1. The future of oil supply

    PubMed Central

    Miller, Richard G.; Sorrell, Steven R.

    2014-01-01

    Abundant supplies of oil form the foundation of modern industrial economies, but the capacity to maintain and grow global supply is attracting increasing concern. Some commentators forecast a peak in the near future and a subsequent terminal decline in global oil production, while others highlight the recent growth in ‘tight oil’ production and the scope for developing unconventional resources. There are disagreements over the size, cost and recoverability of different resources, the technical and economic potential of different technologies, the contribution of different factors to market trends and the economic implications of reduced supply. Few debates are more important, more contentious, more wide-ranging or more confused. This paper summarizes the main concepts, terms, issues and evidence that are necessary to understand the ‘peak oil’ debate. These include: the origin, nature and classification of oil resources; the trends in oil production and discoveries; the typical production profiles of oil fields, basins and producing regions; the mechanisms underlying those profiles; the extent of depletion of conventional oil; the risk of an approaching peak in global production; and the potential of various mitigation options. The aim is to introduce the subject to non-specialist readers and provide a basis for the subsequent papers in this Theme Issue. PMID:24298085

  2. Pulse doubling in zigzag-connected autotransformer-based 12-pulse ac-dc converter for power quality improvement

    NASA Astrophysics Data System (ADS)

    Abdollahi, Rohollah

    2012-12-01

    This paper presents a pulse doubling technique in a 12-pulse ac-dc converter which supplies direct torque controlled motor drives (DTCIMDs) in order to have better power quality conditions at the point of common coupling. The proposed technique increases the number of rectification pulses without significant changes in the installations and yields in harmonic reduction in both ac and dc sides. The 12-pulse rectified output voltage is accomplished via two paralleled six-pulse acdc converters each of them consisting of three-phase diode bridge rectifiers. An autotransformer is designed to supply the rectifiers. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications where a six-pulse diode bridge rectifier is being utilized. Independent operation of paralleled diode-bridge rectifiers, i.e. dc-ripple re-injection methodology, requires a Zero Sequence Blocking Transformer (ZSBT). Finally, a tapped interphase reactor is connected at the output of ZSBT to double the pulse numbers of output voltage up to 24 pulses. The aforementioned structure improves power quality criteria at ac mains and makes them consistent with the IEEE-519 standard requirements for varying loads. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6-pulse, 12-pulse, and proposed converters from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 5% for the proposed topology at various loads.

  3. EC Transmission Line Materials

    SciTech Connect

    Bigelow, Tim S

    2012-05-01

    The purpose of this document is to identify materials acceptable for use in the US ITER Project Office (USIPO)-supplied components for the ITER Electron cyclotron Heating and Current Drive (ECH&CD) transmission lines (TL), PBS-52. The source of material property information for design analysis shall be either the applicable structural code or the ITER Material Properties Handbook. In the case of conflict, the ITER Material Properties Handbook shall take precedence. Materials selection, and use, shall follow the guidelines established in the Materials Assessment Report (MAR). Materials exposed to vacuum shall conform to the ITER Vacuum Handbook. [Ref. 2] Commercial materials shall conform to the applicable standard (e.g., ASTM, JIS, DIN) for the definition of their grade, physical, chemical and electrical properties and related testing. All materials for which a suitable certification from the supplier is not available shall be tested to determine the relevant properties, as part of the procurement. A complete traceability of all the materials including welding materials shall be provided. Halogenated materials (example: insulating materials) shall be forbidden in areas served by the detritiation systems. Exceptions must be approved by the Tritium System and Safety Section Responsible Officers.

  4. VizieR Online Data Catalog: Hubble Legacy Archive ACS grism data (Kuemmel+, 2011)

    NASA Astrophysics Data System (ADS)

    Kuemmel, M.; Rosati, P.; Fosbury, R.; Haase, J.; Hook, R. N.; Kuntschner, H.; Lombardi, M.; Micol, A.; Nilsson, K. K.; Stoehr, F.; Walsh, J. R.

    2011-09-01

    A public release of slitless spectra, obtained with ACS/WFC and the G800L grism, is presented. Spectra were automatically extracted in a uniform way from 153 archival fields (or "associations") distributed across the two Galactic caps, covering all observations to 2008. The ACS G800L grism provides a wavelength range of 0.55-1.00um, with a dispersion of 40Å/pixel and a resolution of ~80Å for point-like sources. The ACS G800L images and matched direct images were reduced with an automatic pipeline that handles all steps from archive retrieval, alignment and astrometric calibration, direct image combination, catalogue generation, spectral extraction and collection of metadata. The large number of extracted spectra (73,581) demanded automatic methods for quality control and an automated classification algorithm was trained on the visual inspection of several thousand spectra. The final sample of quality controlled spectra includes 47919 datasets (65% of the total number of extracted spectra) for 32149 unique objects, with a median iAB-band magnitude of 23.7, reaching 26.5 AB for the faintest objects. Each released dataset contains science-ready 1D and 2D spectra, as well as multi-band image cutouts of corresponding sources and a useful preview page summarising the direct and slitless data, astrometric and photometric parameters. This release is part of the continuing effort to enhance the content of the Hubble Legacy Archive (HLA) with highly processed data products which significantly facilitate the scientific exploitation of the Hubble data. In order to characterize the slitless spectra, emission-line flux and equivalent width sensitivity of the ACS data were compared with public ground-based spectra in the GOODS-South field. An example list of emission line galaxies with two or more identified lines is also included, covering the redshift range 0.2-4.6. Almost all redshift determinations outside of the GOODS fields are new. The scope of science projects possible

  5. Evaluation of the Webler-Brown model for estimating tetrachloroethylene exposure from vinyl-lined asbestos-cement pipes

    PubMed Central

    Spence, Lisa A; Aschengrau, Ann; Gallagher, Lisa E; Webster, Thomas F; Heeren, Timothy C; Ozonoff, David M

    2008-01-01

    Background From May 1968 through March 1980, vinyl-lined asbestos-cement (VL/AC) water distribution pipes were installed in New England to avoid taste and odor problems associated with asbestos-cement pipes. The vinyl resin was applied to the inner pipe surface in a solution of tetrachloroethylene (perchloroethylene, PCE). Substantial amounts of PCE remained in the liner and subsequently leached into public drinking water supplies. Methods Once aware of the leaching problem and prior to remediation (April-November 1980), Massachusetts regulators collected drinking water samples from VL/AC pipes to determine the extent and severity of the PCE contamination. This study compares newly obtained historical records of PCE concentrations in water samples (n = 88) with concentrations estimated using an exposure model employed in epidemiologic studies on the cancer risk associated with PCE-contaminated drinking water. The exposure model was developed by Webler and Brown to estimate the mass of PCE delivered to subjects' residences. Results The mean and median measured PCE concentrations in the water samples were 66 and 0.5 μg/L, respectively, and the range extended from non-detectable to 2432 μg/L. The model-generated concentration estimates and water sample concentrations were moderately correlated (Spearman rank correlation coefficient = 0.48, p < 0.0001). Correlations were higher in samples taken at taps and spigots vs. hydrants (ρ = 0.84 vs. 0.34), in areas with simple vs. complex geometry (ρ = 0.51 vs. 0.38), and near pipes installed in 1973–1976 vs. other years (ρ = 0.56 vs. 0.42 for 1968–1972 and 0.37 for 1977–1980). Overall, 24% of the variance in measured PCE concentrations was explained by the model-generated concentration estimates (p < 0.0001). Almost half of the water samples had undetectable concentrations of PCE. Undetectable levels were more common in areas with the earliest installed VL/AC pipes, at the beginning and middle of VL/AC pipes, at

  6. A 52-week safety study in cynomolgus macaques for genetically modified rice expressing Cry1Ab/1Ac protein.

    PubMed

    Mao, Jie; Sun, Xing; Cheng, Jian-Hua; Shi, Yong-Jie; Wang, Xin-Zheng; Qin, Jun-Jie; Sang, Zhi-Hong; He, Kun; Xia, Qing

    2016-09-01

    A 52-week feeding study in cynomolgus macaques was carried out to evaluate the safety of Bt rice Huahui 1 (HH1), a transgenic rice line expressing Cry1Ab/1Ac protein. Monkeys were fed a diet with 20% or 60% HH1 rice, 20% or 60% parental rice (Minghui 63, MH63), normal diet, normal diet spiked with purified recombinant Cry1Ab/1Ac fusion protein or bovine serum albumin (BSA) respectively. During the feeding trail, clinical observations were conducted daily, and multiple parameters, including body weight, body temperature, electrocardiogram, hematology, blood biochemistry, serum metabolome and gut microbiome were examined at regular intervals. Upon sacrifice, the organs were weighted, and the macroscopic, microscopic and electron microscopic examinations were performed. The results show no adverse or toxic effects of Bt rice HH1 or Cry1Ab/1Ac fusion protein on monkeys. Therefore, the present 52-week primate feeding study suggests that the transgenic rice containing Cry 1Ab/1Ac is equivalent to its parental rice line MH63. PMID:27338709

  7. Human MUC5AC mucin dimerizes in the rough endoplasmic reticulum, similarly to the MUC2 mucin.

    PubMed Central

    Asker, N; Axelsson, M A; Olofsson, S O; Hansson, G C

    1998-01-01

    Biosynthetic studies on the human MUC5AC mucin were performed by immunoprecipitations with antisera recognizing only the non-O-glycosylated apomucin in the colon adenocarcinoma cell line LS 174T. Pulse-chase studies and subcellular fractionations showed that MUC5AC formed dimers in the rough endoplasmic reticulum within 15 min of the initiation of biosynthesis. No non-O-glycosylated species larger than dimers were identified. The dimerization was N-glycosylation-dependent, because tunicamycin treatment significantly lowered the rate of dimerization. When the biosynthesis of MUC5AC apomucin was compared with that of MUC2 apomucin, also produced in the LS 174T cell line, both apomucins were assembled in similar ways with respect to their rates of dimerization with and without inhibition of N-glycosylation. No heterodimerization was observed between the human MUC5AC and the MUC2 apomucins despite the extensive sequence similarities in the positions of the cysteine residues in the C-termini proposed to be involved in mucin dimerization. PMID:9761738

  8. Production Of Multi-magnetron Plasma By Using Polyphase Ac Glow Discharge In An Improved Multi-pole Magnetic Field

    NASA Astrophysics Data System (ADS)

    Matsumoto, Kazunori; Motoki, Kentaro; Miyamoto, Masahiro; Uetani, Yasuhiro

    1998-10-01

    Effects of an improved multi-pole magnetic field on a plasma production generated by a polyphase ac glow discharge with multiple electrodes have been investigated. Conventional configuration of the multi-pole magnetic filed has been modified to suppress plasma losses at both ends of the chamber due to ExB drift motion. The modified multi-pole magnetic field has enabled us to produce a multiple magnetron-plasma at a considerably low pressure less than mTorr. The low temperature plasma has been widely used as the fine processing technology of a dry etching and as the thin film formation technology of a sputtering coating. Large-scale plasmas which can be generated at a low gas-pressure have been desired for more wider dry etching and greater sputter coating. The purpose of this study is to develop a large-scale and low-cost plasma generator by using a polyphase ac power source with the low frequency. In this session, we will present the experimental result as to a multiple magnetron-plasma generated in the modified twenty-four poles magnetic field by using the twenty-four-phase ac power source with the commercial electric power frequency of 60Hz. The ac power is supplied to twenty-four electrodes which are fixed to the water-cooled chamber-wall through sheet insulators so that the electrodes can be cooled indirectly.

  9. Study of AC electrical conduction mechanisms in an epoxy polymer

    NASA Astrophysics Data System (ADS)

    Jilani, Wissal; Mzabi, Nissaf; Gallot-Lavallée, Olivier; Fourati, Najla; Zerrouki, Chouki; Zerrouki, Rachida; Guermazi, Hajer

    2015-11-01

    The AC conductivity of an epoxy resin was investigated in the frequency range 10^{-1} - 106 Hz at temperatures ranging from -100 to 120 °C. The frequency dependence of σ_{ac} was described by the law: σ_{ac}=ω \\varepsilon0\\varepsilon^''_{HN}+Aωs. The study of temperature variation of the exponent (s) reveals two conduction models: the AC conduction dependence upon temperature is governed by the small polaron tunneling mechanism (SPTM) at low temperature (-100 -60 °C) and the correlated barrier hopping (CHB) model at high temperature (80-120 °C).

  10. AC Electrokinetic Bacteria/Virus Traps and Separatrix Crossing

    NASA Astrophysics Data System (ADS)

    Hou, Diana; Chang, Hsueh-Chia

    2004-11-01

    A fast and long-range bacteria/virus trap is developed with a dynamical systems approach, by optimizing AC electro-osmotic (ACEO) flow fields on micro-fabricated electrodes. The bacteria are convected to the designated locations three orders of magnitude faster than any motion driven by particle forces. Optimal time-varying flow fields are designed via dynamical system theory by employing the opposite flow directions of capacitive and Faradaic ACEO flows and by judiciously introducing local particle-attracting DEP elements at the converging stagnation lines on the electrodes. The latter elements shift the unstable saddle point of the liquid flow field such that an attracting trap region appears on the electrode for the particle flow field. Time-periodic forcing breaks heteroclinic orbits that bound circulation regions in the bulk sample such that the trap becomes a global attractor. The multi-scale electrode assembly is able to trap most of the bacteria in a ml-sample, with a low CFU count of one thousand per cc, within two minutes. The particle density is increased by four orders of magnitude such that their fluorescent intensity, after molecular tags have been added, is dramatically magnified to allow detection. Virus and nanoparticle trajectories in the micro-fluidic device are imaged with fluorescent imaging.

  11. AC Electroosmotic Pumping in Nanofluidic Funnels.

    PubMed

    Kneller, Andrew R; Haywood, Daniel G; Jacobson, Stephen C

    2016-06-21

    We report efficient pumping of fluids through nanofluidic funnels when a symmetric AC waveform is applied. The asymmetric geometry of the nanofluidic funnel induces not only ion current rectification but also electroosmotic flow rectification. In the base-to-tip direction, the funnel exhibits a lower ion conductance and a higher electroosmotic flow velocity, whereas, in the tip-to-base direction, the funnel has a higher ion conductance and a lower electroosmotic flow velocity. Consequently, symmetric AC waveforms easily pump fluid through the nanofunnels over a range of frequencies, e.g., 5 Hz to 5 kHz. In our experiments, the nanofunnels were milled into glass substrates with a focused ion beam (FIB) instrument, and the funnel design had a constant 5° taper with aspect ratios (funnel tip width to funnel depth) of 0.1 to 1.0. We tracked ion current rectification by current-voltage (I-V) response and electroosmotic flow rectification by transport of a zwitterionic fluorescent probe. Rectification of ion current and electroosmotic flow increased with increasing electric field applied to the nanofunnel. Our results support three-dimensional simulations of ion transport and electroosmotic transport through nanofunnels, which suggest the asymmetric electroosmotic transport stems from an induced pressure at the junction of the nanochannel and nanofunnel tip. PMID:27230495

  12. Fabrication of a flexible Ag-grid transparent electrode using ac based electrohydrodynamic Jet printing

    NASA Astrophysics Data System (ADS)

    Park, Jaehong; Hwang, Jungho

    2014-10-01

    In the dc voltage-applied electrohydrodynamic (EHD) jet printing of metal nanoparticles, the residual charge of droplets deposited on a substrate changes the electrostatic field distribution and interrupts the subsequent printing behaviour, especially for insulating substrates that have slow charge decay rates. In this paper, a sinusoidal ac voltage was used in the EHD jet printing process to switch the charge polarity of droplets containing Ag nanoparticles, thereby neutralizing the charge on a polyethylene terephthalate (PET) substrate. Printed Ag lines with a width of 10 µm were invisible to the naked eye. After sintering lines with 500 µm of line pitch at 180 °C, a grid-type transparent electrode (TE) with a sheet resistance of ˜7 Ω sq-1 and a dc to optical conductivity ratio of ˜300 at ˜84.2% optical transmittance was obtained, values that were superior to previously reported results. In order to evaluate the durability of the TE under bending stresses, the sheet resistance was measured as the number of bending cycles was increased. The sheet resistance of the Ag grid electrode increased only slightly, by less than 20% from its original value, even after 500 cycles. To the best of our knowledge, this is the first time that Ag (invisible) grid TEs have been fabricated on PET substrates by ac voltage applied EHD jet printing.

  13. Differential Expression of O-glycoprotein Glycans in Cholangiocarcinoma Cell Lines

    PubMed Central

    Talabnin, Krajang; Talabnin, Chutima; Ishihara, Mayumi; Azadi, Parastoo; Wongkham, Sopit; Sripa, Banchob

    2016-01-01

    Protein glycosylation is the most common posttranslational modification in mammalian cells. Aberrant protein glycosylation has been reported in various diseases, including cancer. We identified and quantified the glycan structures of O-linked glycoprotein from cholangiocarcinoma (CCA) cell lines from different histological types and compared their profiles by nanospray ionization-linear ion trap mass spectrometry (NSI-MSn). Five human CCA cell lines, K100, M055, M139, M213 and M214 were characterized. The results showed that the O-linked glycans of the CCA cell lines comprised tri- to hexa-saccharides with terminal galactose and sialic acids: NeuAc1Gal1GalNAc1, Gal2GlcNAc1GalNAc1, NeuAc2Gal1GalNAc1 NeuAc1Gal2GlcNAc1GalNAc1 and NeuAc2Gal2GlcNAc1GalNAc1 All five CCA cell lines showed a similar glycan pattern, but with differences in their quantities. NeuAc1Gal1GalNAc1 proved to be the most abundant structure in poorly differentiated adenocarcinoma (K100; 57.1%), moderately differentiated adenocarcinoma (M055; 42.6%) and squamous cell carcinoma (M139; 43.0%), while moderately to poorly differentiated adenocarcinoma (M214; 40.1%) and adenosquamous cell carcinoma (M213; 34.7%) appeared dominated by NeuAc2Gal1GalNAc1. These results demonstrate differential expression of the O-linked glycans in the different histological types of CCA. All five CCA cell lines have abundant terminal sialic acid (NeuAc) O-linked glycans, suggesting an important role for sialic acid in cancer cells. Our structural analyses of glycans may provide important information regarding physiology of disease-related glycoproteins in CCA. PMID:26925665

  14. Information flow in the pharmaceutical supply chain.

    PubMed

    Yousefi, Nazila; Alibabaei, Ahmad

    2015-01-01

    Managing the supply chain plays an important role in creating competitive advantages for companies. Adequate information flow in supply chain is one of the most important issues in SCM. Therefore, using certain Information Systems can have a significant role in managing and integrating data and information within the supply chain. Pharmaceutical supply chain is more complex than many other supply chains, in the sense that it can affect social and political perspectives. On the other hand, managing the pharmaceutical supply chain is difficult because of its complexity and also government regulations in this field. Although, Iran has progressed a lot in pharmaceutical manufacturing, still there are many unsolved issues in managing the information flow in the pharmaceutical supply chain. In this study, we reviewed the benefits of using different levels of an integrated information system in the supply chain and the possible challenges ahead. PMID:26664401

  15. Information flow in the pharmaceutical supply chain

    PubMed Central

    Yousefi, Nazila; Alibabaei, Ahmad

    2015-01-01

    Managing the supply chain plays an important role in creating competitive advantages for companies. Adequate information flow in supply chain is one of the most important issues in SCM. Therefore, using certain Information Systems can have a significant role in managing and integrating data and information within the supply chain. Pharmaceutical supply chain is more complex than many other supply chains, in the sense that it can affect social and political perspectives. On the other hand, managing the pharmaceutical supply chain is difficult because of its complexity and also government regulations in this field. Although, Iran has progressed a lot in pharmaceutical manufacturing, still there are many unsolved issues in managing the information flow in the pharmaceutical supply chain. In this study, we reviewed the benefits of using different levels of an integrated information system in the supply chain and the possible challenges ahead. PMID:26664401

  16. Waterborne cryptosporidiosis associated with a borehole supply.

    PubMed

    Morgan, D; Allaby, M; Crook, S; Casemore, D; Healing, T D; Soltanpoor, N; Hill, S; Hooper, W

    1995-06-23

    From 1 April to 31 May 1993, 64 cases of cryptosporidiosis were diagnosed within one district health authority. Forty were classified as primary cases, 35 of whom were clustered in an area supplied by a discrete public water supply that supplied the majority of homes in a large town. Most of the water in this supply is abstracted from boreholes and some is filtered before distribution. Households that received mains water from this supply were 15 times more likely to be affected than households nearby that received water from other sources. A case control study demonstrated a dose response relationship between consumption of water obtained from the town supply and risk of illness. Very low concentrations of cryptosporidial oocysts were detected in the water supply on four occasions several weeks after the outbreak. Environmental investigation failed to reveal a likely mechanism for contamination of the water supply. PMID:7613587

  17. 40 CFR 35.6305 - Obtaining supplies.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....6325 through 35.6340, and 35.6350. Supplies obtained with Core Program funds must be for non-site-specific purposes. All purchases of supplies under the Core Program must comply with the requirements...

  18. Power Supply For 25-Watt Arc Lamp

    NASA Technical Reports Server (NTRS)

    Leighty, B. D.

    1985-01-01

    Dual-voltage circuitry both strikes and maintains arc. New power supply designed (and several units already in use) that replaces relay/choke combination with solid-state starter. New power supply consists of two main sections. First section (low voltage power supply section) is 84-volt directcurrent supply. Second section (high-voltage starter circuit) is CockroftWalton voltage multiplier. Used as light sources for schlieren, shadowgraph, and other flow-visualization techniques.

  19. Simple constant-current-regulated power supply

    NASA Technical Reports Server (NTRS)

    Priebe, D. H. E.; Sturman, J. C.

    1977-01-01

    Supply incorporates soft-start circuit that slowly ramps current up to set point at turn-on. Supply consists of full-wave rectifier, regulating pass transistor, current feedback circuit, and quad single-supply operational-amplifier circuit providing control. Technique is applicable to any system requiring constant dc current, such as vacuum tube equipment, heaters, or battery charges; it has been used to supply constant current for instrument calibration.

  20. Strategic materials availability and supply

    NASA Technical Reports Server (NTRS)

    Stephens, Joseph R.

    1989-01-01

    An evaluation is made of the supply sources and current availability of elements involved in superalloy compositions, as well as of development trends in the substitution of strategic materials for superalloys, giving attention to the results thus far achieved by NASA's Conservation of Strategic Aerospace Materials program, which formally operated only from 1980 to 1984 but whose various research initiatives have been continued under other NASA programs. Peacetime and wartime economies' need and probable availability analyses are presented for bauxite/aluminum, the Pt-group metals, and the alloying elements Mn, Nb, Ta, Co, Cr, Ni, W, Fe, Cu, Ti, Mo, and Mg.

  1. Preprototype nitrogen supply subsystem development

    NASA Technical Reports Server (NTRS)

    Heppner, D. B.; Fort, J. H.; Schubert, F. H.

    1982-01-01

    The design and development of a test stand for the Nitrogen Generation Module (NGM) and a series of tests which verified its operation and performance capability are described. Over 900 hours of parametric testing were achieved. The results from this testing were then used to design an advanced NGM and a self contained, preprototype Nitrogen Supply Subsystem. The NGM consists of three major components: nitrogen generation module, pressure controller and hydrazine storage tank and ancillary components. The most important improvement is the elimination of all sealing surfaces, achieved with a total welded or brazed construction. Additionally, performance was improved by increasing hydrogen separating capability by 20% with no increase in overall packaging size.

  2. Petroleum supply monthly: December 1993

    SciTech Connect

    Not Available

    1993-12-01

    Data are presented which describe the supply and disposition of petroleum products in the United States and major U.S. geographic regions. The data series describe production, imports and exports, inter-Petroleum Administration for Defense (PAD) District movements, and inventories by the primary suppliers of petroleum products in the United States. Data are presented in two sections: Summary Statistics, presenting a time series of selected petroleum data on a U.S. level, and Detailed Statistics, presenting statistics for the most current month available as well as year to date.

  3. Disrupted bandcount doubling in an AC-DC boost PFC circuit modeled by a time varying map

    NASA Astrophysics Data System (ADS)

    Avrutin, Viktor; Zhusubaliyev, Zhanybai T.; El Aroudi, Abdelali; Fournier-Prunaret, Danièle; Garcia, Germain; Mosekilde, Erik

    2016-02-01

    Power factor correction converters are used in many applications as AC-DC power supplies aiming at maintaining a near unity power factor. Systems of this type are known to exhibit nonlinear phenomena such as sub-harmonic oscillations and chaotic regimes that cannot be described by traditional averaged models. In this paper, we derive a time varying discretetime map modeling the behavior of a power factor correction AC-DC boost converter. This map is derived in closed-form and is able to faithfully reproduce the system behavior under realistic conditions. In the chaotic regime the map exhibits a sequence of bifurcation similar to a bandcount doubling cascade on the low frequency. However, the observed scenario appears in some sense incomplete, with some gaps in the bifurcation diagram, whose appearance to our knowledge has never been reported before. We show that these gaps are caused by high frequency oscillations.

  4. Ac45 silencing mediated by AAV-sh-Ac45-RNAi prevents both bone loss and inflammation caused by periodontitis

    PubMed Central

    Zhu, Zheng; Chen, Wei; Hao, Liang; Zhu, Guochun; Lu, Yun; Li, Sheng; Wang, Lin; Li, Yi-Ping

    2015-01-01

    Aim Periodontitis induced by oral pathogens leads to severe periodontal tissue damage and osteoclast-mediated bone resorption caused by inflammation. Based on the importance of Ac45 in osteoclast formation and function, we performed this study to evaluate the therapeutic potential of periodontitis by local adeno-associated virus (AAV)-mediated Ac45 gene knockdown. Material and Methods We used AAV-mediated short hairpin RNAi knockdown of Ac45 gene expression (AAV-sh-Ac45) to inhibit bone erosion and gingival inflammation simultaneously in a well-established periodontitis mouse model induced by Porphyromonas gingivalis W50. Histological studies were performed to evaluate the bone protection of AAV-sh-Ac45. Immunochemistry, ELISA and qRT-PCR were performed to reveal the role of Ac45 knockdown on inflammation, immune response and expression of cytokine. Results We found that Ac45 knockdown impaired osteoclast-mediated extracellular acidification and bone resorption in vitro and in vivo. Furthermore, local administration of AAV-sh-Ac45 protected mice from bone erosion by >85% and attenuated inflammation and decreased infiltration of T-cells, dendritic cells and macrophages in the periodontal lesion. Notably, the expression of pro-inflammatory cytokines was also reduced. Conclusions Local AAV-sh-Ac45 gene therapy efficiently protects against periodontal tissue damage and bone erosion through both inhibition of osteoclast function and attenuating inflammation, and may represent a powerful new treatment strategy for periodontitis. PMID:25952706

  5. 48 CFR 11.701 - Supply contracts.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Supply contracts. 11.701... DESCRIBING AGENCY NEEDS Variation in Quantity 11.701 Supply contracts. (a) A fixed-price supply contract may... of both; however, contracts for subsistence items may use other applicable terms of variation...

  6. Visualisation for System Learning in Supply Chains

    ERIC Educational Resources Information Center

    Lindskog, Magnus; Abrahamsson, Mats; Aronsson, Hakan

    2007-01-01

    Contemporary supply chains are vastly complex, and decisions made by actors have system-wide consequences that these might not be able to foresee. There are gaps between "best practice"-founded theory and actual practice in supply chains. To remedy this, we argue, the supply chain actors need to enhance systems knowledge. There is a need to…

  7. Learning to Integrate: Supply Chains Reconceptualised

    ERIC Educational Resources Information Center

    Sense, Andrew J.; Clements, Michael D. J.

    2007-01-01

    This paper introduces and explains a conception of supply chains from a situated learning perspective. This non-conventional supply chain perspective invites the reader to consider supply chain scenarios as "situated learning opportunities involving multiple communities of practice" interacting and participating together. It is argued that by…

  8. 20 CFR 654.405 - Water supply.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 3 2012-04-01 2012-04-01 false Water supply. 654.405 Section 654.405... THE EMPLOYMENT SERVICE SYSTEM Housing for Agricultural Workers Housing Standards § 654.405 Water supply. (a) An adequate and convenient supply of water that meets the standards of the State...

  9. 24 CFR 3285.603 - Water supply.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Water supply. 3285.603 Section 3285... § 3285.603 Water supply. (a) Crossover. Multi-section homes with plumbing in both sections require water... pressure and reduction. When the local water supply pressure exceeds 80 psi to the manufactured home,...

  10. 9 CFR 354.224 - Water supply.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Water supply. 354.224 Section 354.224....224 Water supply. The water supply shall be ample, clean, and potable with adequate facilities for its distribution in the plant and its protection against contamination and pollution. (a) Hot water at...

  11. 20 CFR 654.405 - Water supply.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Water supply. 654.405 Section 654.405... THE EMPLOYMENT SERVICE SYSTEM Housing for Agricultural Workers Housing Standards § 654.405 Water supply. (a) An adequate and convenient supply of water that meets the standards of the State...

  12. 24 CFR 3285.603 - Water supply.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Water supply. 3285.603 Section 3285... § 3285.603 Water supply. (a) Crossover. Multi-section homes with plumbing in both sections require water... pressure and reduction. When the local water supply pressure exceeds 80 psi to the manufactured home,...

  13. 25 CFR 137.1 - Water supply.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Water supply. 137.1 Section 137.1 Indians BUREAU OF... CARLOS INDIAN IRRIGATION PROJECT, ARIZONA § 137.1 Water supply. The engineering report dealt with in... capacity of the San Carlos reservoir created by the Coolidge Dam and the water supply therefor over...

  14. 9 CFR 354.224 - Water supply.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Water supply. 354.224 Section 354.224....224 Water supply. The water supply shall be ample, clean, and potable with adequate facilities for its distribution in the plant and its protection against contamination and pollution. (a) Hot water at...

  15. 20 CFR 654.405 - Water supply.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 3 2014-04-01 2014-04-01 false Water supply. 654.405 Section 654.405... THE EMPLOYMENT SERVICE SYSTEM Housing for Agricultural Workers Housing Standards § 654.405 Water supply. (a) An adequate and convenient supply of water that meets the standards of the State...

  16. 9 CFR 354.224 - Water supply.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Water supply. 354.224 Section 354.224....224 Water supply. The water supply shall be ample, clean, and potable with adequate facilities for its distribution in the plant and its protection against contamination and pollution. (a) Hot water at...

  17. 25 CFR 137.1 - Water supply.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 25 Indians 1 2014-04-01 2014-04-01 false Water supply. 137.1 Section 137.1 Indians BUREAU OF... CARLOS INDIAN IRRIGATION PROJECT, ARIZONA § 137.1 Water supply. The engineering report dealt with in... capacity of the San Carlos reservoir created by the Coolidge Dam and the water supply therefor over...

  18. 25 CFR 137.1 - Water supply.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 25 Indians 1 2013-04-01 2013-04-01 false Water supply. 137.1 Section 137.1 Indians BUREAU OF... CARLOS INDIAN IRRIGATION PROJECT, ARIZONA § 137.1 Water supply. The engineering report dealt with in... capacity of the San Carlos reservoir created by the Coolidge Dam and the water supply therefor over...

  19. 24 CFR 3285.603 - Water supply.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Water supply. 3285.603 Section 3285... § 3285.603 Water supply. (a) Crossover. Multi-section homes with plumbing in both sections require water... pressure and reduction. When the local water supply pressure exceeds 80 psi to the manufactured home,...

  20. 25 CFR 137.1 - Water supply.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 25 Indians 1 2012-04-01 2011-04-01 true Water supply. 137.1 Section 137.1 Indians BUREAU OF INDIAN... INDIAN IRRIGATION PROJECT, ARIZONA § 137.1 Water supply. The engineering report dealt with in section 1... of the San Carlos reservoir created by the Coolidge Dam and the water supply therefor over a...

  1. 25 CFR 137.1 - Water supply.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 25 Indians 1 2011-04-01 2011-04-01 false Water supply. 137.1 Section 137.1 Indians BUREAU OF... CARLOS INDIAN IRRIGATION PROJECT, ARIZONA § 137.1 Water supply. The engineering report dealt with in... capacity of the San Carlos reservoir created by the Coolidge Dam and the water supply therefor over...

  2. 20 CFR 654.405 - Water supply.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 3 2013-04-01 2013-04-01 false Water supply. 654.405 Section 654.405... THE EMPLOYMENT SERVICE SYSTEM Housing for Agricultural Workers Housing Standards § 654.405 Water supply. (a) An adequate and convenient supply of water that meets the standards of the State...

  3. 20 CFR 654.405 - Water supply.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Water supply. 654.405 Section 654.405... THE EMPLOYMENT SERVICE SYSTEM Housing for Agricultural Workers Housing Standards § 654.405 Water supply. (a) An adequate and convenient supply of water that meets the standards of the State...

  4. 9 CFR 354.224 - Water supply.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Water supply. 354.224 Section 354.224....224 Water supply. The water supply shall be ample, clean, and potable with adequate facilities for its distribution in the plant and its protection against contamination and pollution. (a) Hot water at...

  5. 24 CFR 3285.603 - Water supply.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Water supply. 3285.603 Section 3285... § 3285.603 Water supply. (a) Crossover. Multi-section homes with plumbing in both sections require water... pressure and reduction. When the local water supply pressure exceeds 80 psi to the manufactured home,...

  6. 9 CFR 354.224 - Water supply.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Water supply. 354.224 Section 354.224....224 Water supply. The water supply shall be ample, clean, and potable with adequate facilities for its distribution in the plant and its protection against contamination and pollution. (a) Hot water at...

  7. 24 CFR 3285.603 - Water supply.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Water supply. 3285.603 Section 3285... § 3285.603 Water supply. (a) Crossover. Multi-section homes with plumbing in both sections require water... pressure and reduction. When the local water supply pressure exceeds 80 psi to the manufactured home,...

  8. Switching System for Redundant Power Supplies

    NASA Technical Reports Server (NTRS)

    Bradford, M.; Grant, R.; Parkinson, G.

    1986-01-01

    Load-transfer unit connects airborne computer to standby power supply in case primary supply fails. Concept adaptable to systems in which power interruptions cannot be tolerated; for example, computers with volatile memories, safety equipment, and precise timers. Load-transfer unit monitors voltages and load current. Microprocessor controls transistor switches that connect load to whichever power supply has highest priority and correct voltage.

  9. 7 CFR 1000.6 - Supply plant.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 9 2012-01-01 2012-01-01 false Supply plant. 1000.6 Section 1000.6 Agriculture... Definitions § 1000.6 Supply plant. Supply plant means a plant approved by a duly constituted regulatory agency... diverts fluid milk products to other plants or manufactures dairy products on its premises....

  10. 7 CFR 1000.6 - Supply plant.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 9 2011-01-01 2011-01-01 false Supply plant. 1000.6 Section 1000.6 Agriculture... Definitions § 1000.6 Supply plant. Supply plant means a plant approved by a duly constituted regulatory agency... diverts fluid milk products to other plants or manufactures dairy products on its premises....

  11. 7 CFR 1000.6 - Supply plant.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true Supply plant. 1000.6 Section 1000.6 Agriculture... Definitions § 1000.6 Supply plant. Supply plant means a plant approved by a duly constituted regulatory agency... diverts fluid milk products to other plants or manufactures dairy products on its premises....

  12. 7 CFR 1000.6 - Supply plant.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 9 2014-01-01 2013-01-01 true Supply plant. 1000.6 Section 1000.6 Agriculture... Definitions § 1000.6 Supply plant. Supply plant means a plant approved by a duly constituted regulatory agency... diverts fluid milk products to other plants or manufactures dairy products on its premises....

  13. 7 CFR 1000.6 - Supply plant.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 9 2013-01-01 2013-01-01 false Supply plant. 1000.6 Section 1000.6 Agriculture... Definitions § 1000.6 Supply plant. Supply plant means a plant approved by a duly constituted regulatory agency... diverts fluid milk products to other plants or manufactures dairy products on its premises....

  14. 24 CFR 3280.803 - Power supply.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Power supply. 3280.803 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Electrical Systems § 3280.803 Power supply. (a) The power supply to the manufactured home shall be a feeder assembly consisting of not more than...

  15. 24 CFR 3280.803 - Power supply.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Power supply. 3280.803 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Electrical Systems § 3280.803 Power supply. Link to an amendment published at 78 FR 73990, Dec. 9, 2013. (a) The power supply to the...

  16. 24 CFR 3280.803 - Power supply.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Power supply. 3280.803 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Electrical Systems § 3280.803 Power supply. (a) The power supply to the manufactured home shall be a feeder assembly consisting of not more than...

  17. 24 CFR 3280.803 - Power supply.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Power supply. 3280.803 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Electrical Systems § 3280.803 Power supply. (a) The power supply to the manufactured home shall be a feeder assembly consisting of not more than...

  18. 24 CFR 3280.803 - Power supply.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Power supply. 3280.803 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Electrical Systems § 3280.803 Power supply. (a) The power supply to the manufactured home shall be a feeder assembly consisting of not more than...

  19. Genetic transformation and expression of transgenic lines of Populus x euramericana with insect-resistance and salt-tolerance genes.

    PubMed

    Yang, R L; Wang, A X; Zhang, J; Dong, Y; Yang, M S; Wang, J M

    2016-01-01

    We characterized new transgenic varieties of poplar with multiple insect-resistant and salt stress tolerant genes. Two insect-resistant Bacillus thuringiensis (Bt) genes, Cry1Ac and Cry3A, and a salt-tolerant gene, Betaine aldehyde dehydrogenase (BADH) were inserted into a vector, p209-Cry1Ac-Cry3A-BADH. The clone of Populus x euramericana was transformed by the vector using the Agrobacterium-mediated method. Three transgenic lines were assessed using genetic detection and resistance expression analysis. PCR revealed that exogenous genes Cry1Ac, Cry3A, BADH and selective marker gene NPTII were present in three transgenic lines. Quantitative real-time PCR (qPCR) showed significant differences in the transcriptional abundance of three exogenous genes in different lines. Results of assays for Bt toxic proteins showed that the Cry1Ac and Cry3A toxic protein content of each line was 12.83-26.32 and 2108.91-2724.79 ng/g, respectively. The Cry1Ac toxic protein content of different lines was significantly different; the Cry3A toxic protein content was about 100 times higher than that of the Cry1Ac toxic protein. The insect-resistance test revealed the mortality rate of transgenic lines to Hyphantria cunea L1 larvae varied by 42.2-66.7%, which was significantly higher than non-transgenic lines. The mortality rate of L1 and L2 Plagiodera versicolora larvae was 100%. The insecticidal effect of transgenic lines to P. versicolora larvae was higher than that to H. cunea larvae. NaCl stress tolerance of three transgenic lines under 3-6% NaCl concentration was significantly higher than that of non-transgenic lines. PMID:27173305

  20. Sparking protection for MFTF-B neutral beam power supplies

    SciTech Connect

    Cummings, D.B.

    1983-11-30

    This paper describes the upgrade of MFTF-B Neutral Beam Power Supplies for sparking protection. High performance ion sources spark repeatedly so ion source power supplies must be insensitive to sparking. The hot deck houses the series tetrode, arc and filament supplies, and controls. Hot deck shielding has been upgraded and a continuous shield around the arc, filament, gradient grid, and control cables now extends from the hot deck, through the core snubber, to the source. The shield carries accelerating current and connects only to the source. Shielded source cables go through an outer duct which now connects to a ground plane under the hot deck. This hybrid transmission line is a low inductance path for sparks discharging the stray capacitance of the hot deck and isolation transformers, reducing coupling to building steel. Parallel dc current return cables inside the duct lower inductance to reduce inductive turn-off transients. MOVs to ground further limit surges in the remote power supply return. Single point grounding is at the source. No control or rectifier components have been damaged nor are there any known malfunctions due to sparking up to 80 kV output.

  1. Scalable Heuristics for Planning, Placement and Sizing of Flexible AC Transmission System Devices

    SciTech Connect

    Frolov, Vladmir; Backhaus, Scott N.; Chertkov, Michael

    2015-07-02

    Aiming to relieve transmission grid congestion and improve or extend feasibility domain of the operations, we build optimization heuristics, generalizing standard AC Optimal Power Flow (OPF), for placement and sizing of Flexible Alternating Current Transmission System (FACTS) devices of the Series Compensation (SC) and Static VAR Compensation (SVC) type. One use of these devices is in resolving the case when the AC OPF solution does not exist because of congestion. Another application is developing a long-term investment strategy for placement and sizing of the SC and SVC devices to reduce operational cost and improve power system operation. SC and SVC devices are represented by modification of the transmission line inductances and reactive power nodal corrections respectively. We find one placement and sizing of FACTs devices for multiple scenarios and optimal settings for each scenario simultaneously. Our solution of the nonlinear and nonconvex generalized AC-OPF consists of building a convergent sequence of convex optimizations containing only linear constraints and shows good computational scaling to larger systems. The approach is illustrated on single- and multi-scenario examples of the Matpower case-30 model.

  2. Combined AC-STEM and FIB-SEM Characterization of Shale

    NASA Astrophysics Data System (ADS)

    Dewers, T. A.; Heath, J. E.; Kotula, P.; Yoon, H.; Gardner, P.

    2013-12-01

    We examine shale samples with state-of-the-art aberration corrected scanning transmission electron microscopy (AC-STEM) and focused ion beam-scanning electron (FIB-SEM) microscopy. Three-dimensional reconstruction of pore space incorporates electron tomography using the AC-TEM and serial sectioning by FIB-SEM. Chemical analysis by X-ray energy dispersive microscopy reveals composition of pore-lining phases at ~ 1 nm resolution. Our methods reveal the left tail of the pore size distribution that FIB-SEM techniques typically do not capture (pore sizes < 7 nm). Water in pores of this size will deviate from those of bulk water, which can influence non-Darcy flow and mechanical response. The impact of these small pores on fluid and coupled tracer transport is examined by computation fluid dynamics using 3D pore reconstructions. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  3. Statistical modelling of mitochondrial power supply.

    PubMed

    James, A T; Wiskich, J T; Conyers, R A

    1989-01-01

    By experiment and theory, formulae are derived to calculate the response of mitochondrial power supply, in flux and potential, to an ATP consuming enzyme load, incorporating effects of varying amounts of (i) enzyme, (ii) total circulating adenylate, and (iii) inhibition of the ATP/ADP translocase. The formulae, which apply between about 20% and 80% of maximum respiration, are the same as for the current and voltage of an electrical circuit in which a battery with potential, linear in the logarithm of the total adenylate, charges another battery whose opposing potential is also linear in the same logarithm, through three resistances. These resistances produce loss of potential due to dis-equilibrium of (i) intramitochondrial oxidative phosphorylation, (ii) the ATP/ADP translocase, and (iii) the ATP-consuming enzyme load. The model is represented geometrically by the following configuration: when potential is plotted against flux, the points lie on two pencils of lines each concurrent at zero respiration, the two pencils describing the respective characteristics of the mitochondrion and enzyme. Control coefficients and elasticities are calculated from the formulae. PMID:2708917

  4. Alternating current line-filter based on electrochemical capacitor utilizing template-patterned graphene.

    PubMed

    Wu, Zhenkun; Li, Liyi; Lin, Ziyin; Song, Bo; Li, Zhuo; Moon, Kyoung-Sik; Wong, Ching-Ping; Bai, Shu-Lin

    2015-01-01

    Aluminum electrolytic capacitors (AECs) are widely used for alternating current (ac) line-filtering. However, their bulky size is becoming more and more incompatible with the rapid development of portable electronics. Here we report a scalable process to fabricate miniaturized graphene-based ac line-filters on flexible substrates at room temperature. In this work, graphene oxide (GO) is reduced by patterned metal interdigits at room temperature and used directly as the electrode material. The as-fabricated device shows a phase angle of -75.4° at 120 Hz with a specific capacitance of 316 µF/cm(2) and a RC time constant of 0.35 ms. In addition, it retains 97.2% of the initial capacitance after 10000 charge/discharge cycles. These outstanding performance characteristics of our device demonstrate its promising to replace the conventional AECs for ac line filtering. PMID:26084051

  5. Alternating current line-filter based on electrochemical capacitor utilizing template-patterned graphene

    PubMed Central

    Wu, Zhenkun; Li, Liyi; Lin, Ziyin; Song, Bo; Li, Zhuo; Moon, Kyoung-Sik; Wong, Ching-Ping; Bai, Shu-Lin

    2015-01-01

    Aluminum electrolytic capacitors (AECs) are widely used for alternating current (ac) line-filtering. However, their bulky size is becoming more and more incompatible with the rapid development of portable electronics. Here we report a scalable process to fabricate miniaturized graphene-based ac line-filters on flexible substrates at room temperature. In this work, graphene oxide (GO) is reduced by patterned metal interdigits at room temperature and used directly as the electrode material. The as-fabricated device shows a phase angle of −75.4° at 120 Hz with a specific capacitance of 316 µF/cm2 and a RC time constant of 0.35 ms. In addition, it retains 97.2% of the initial capacitance after 10000 charge/discharge cycles. These outstanding performance characteristics of our device demonstrate its promising to replace the conventional AECs for ac line filtering. PMID:26084051

  6. Mars sample return power supply

    NASA Technical Reports Server (NTRS)

    Hoang, Don; Ludwigs, Sharon; Schmitz, Paul; Wright, John

    1988-01-01

    A power supply is designed for a vehicle able to operate on the surface of Mars for a period of 5 to 10 years. This vehicle will be used for sample and data collection. The design is based on the assumption that the vehicle will be unmanned. Also, there will be no means by which components could be repaired or replaced while on the Martian surface. A consequence of this is that all equipment must meet high standards of reliability and, if possible, redundancy. Power will be supplied to the vehicle by means of a General Purpose Heat Source capable of producing a minimum of 7 kW of thermal power. The heat generated from the General Purpose Heat Source will be transferred to a Stirling engine via hot side heat pipes. The Stirling engine will then convert this heat into 2 kW of electrical power. Cold side heat pipes will be used to carry away waste heat, which will be released to the Martian environment via radiators connected to the end of the cold side heat pipes.

  7. Natural Gas Supply SBIR Program

    SciTech Connect

    Shoemaker, H.D.; Gwilliam, W.J.

    1995-07-01

    The Small Business Innovation Research (SBIR) program was created in 1982 by Public Law 97-219 and reauthorized in 1992 until the year 2000 by Public Law 102-564. The purposes of the new law are to (1) expand and improve the SBIR program, 2) emphasize the program`s goal of increasing private sector commercialization of technology developed through Federal R&D, (3) increase small business participation in Federal R&D, and (4) improve the Federal Government`s dissemination of information concerning the SBIR program. DOE`s SBIR pro-ram has two features that are unique. In the 1995 DOE SBIR solicitation, the DOE Fossil Energy topics were: environmental technology for natural gas, oil, and coal; advanced recovery of oil; natural gas supply; natural gas utilization; advanced coal-based power systems; and advanced fossil fuels research. The subtopics for this solicitation`s Natural Gas Supply topic are (1) drilling, completion, and stimulation; (2) low-permeability Formations; (3) delivery and storage; and (4) natural gas upgrading.

  8. Ignitor Electrical Power Supply System

    NASA Astrophysics Data System (ADS)

    Coletti, Alberto; Coletti, Roberto; Costa, Pietro; Maffia, Giuseppe; Ramogida, Giuseppe; Roccella, Massimo; Santinelli, Maurizio; Starace, Fabio

    2004-11-01

    An iterative optimization process to reduce the total installed electrical power required for Ignitor has been performed, bringing its value down to about 70% of that estimated originally. Ignitor is planned to be installed within the 400 kV Station of Rondissone (near Turin). The required electrical power (1000 MVA / 320 MVAr, including 480 MVAr locally compensated through static system, SVC) has been demonstrated by the technical authority GRTN to be compatible with the Grid capability. The magnet systems of Ignitor are supplied by means of a set of 14, 12 pulse, current regulated, sequentially or internal freewheeling controlled, fully static power amplifier units which are installed inside standard, outdoor-kind containers, located near to the related step-down transformers. Each container can house up to 100 MW, 2x12 pulse power amplifier units. The connection between the power amplifiers and the machine is performed by means of coaxial, outdoor-kind, segregated bus-bars. These choices make the whole power supply system as flexible as possible in terms of the overall layout of the Ignitor plant.

  9. Superalloy resources: Supply and availability

    NASA Technical Reports Server (NTRS)

    Stephens, Joseph R.

    1987-01-01

    Over the past several decades there have been shortages of strategic materials because of our near total import dependence on such metals as chromium, cobalt, and tantalum. In response to the continued vulnerability of U.S. superalloy producers to disruptions in resource supplies, NASA has undertaken a program to address alternatives to the super-alloys containing significant quantities of the strategic materials such as chromium, cobalt, niobium, and tantalum. The research program called Conservation of Strategic Aerospace Materials (COSAM) focuses on substitution, processing, and alternate materials to achieve its goals. In addition to NASA Lewis Research Center, universities and industry play an important role in the COSAM Program. This paper defines what is meant by strategic materials in the aerospace community, presents a strategic materials index, and reviews the resource supply and availability picture from the U.S. point of view. In addition, research results from the COSAM Program are highlighted and future directions for the use of low strategic material alloys or alternate materials are discussed.

  10. Intermodulation components in the transmitter RF output due to high voltage power supply ripple

    NASA Technical Reports Server (NTRS)

    Finnegan, E. J.

    1977-01-01

    The economic feasibility of eliminating the 400-Hz motor-generator sets used to provide power to the high-voltage power supplies of the 20-kW transmitters and replace them with a 60-Hz high-voltage power supply was investigated. The efficiency of a power supply that runs from the 60-Hz line directly would pay for itself in about seven years and could be designed so that the transmitter would meet all the incidental phase and amplitude modulation specifications.

  11. Electric Field Lines

    NASA Astrophysics Data System (ADS)

    Arribas, E.; Gallardo, C.; Molina, M.; Sanjosé, V.

    We present the computer program called LINES which is able to calculate and visualize the electric field lines due to seven different discrete configurations of electric point charges. Also we show two examples of the graphic screens generated by LINES.

  12. Drinking Water Supplies: Protection Through Watershed Management

    NASA Astrophysics Data System (ADS)

    Page, G. William

    1984-04-01

    The practice of purchasing land to protect surface water supply sources is rarely practical today. This is particularly true near urban areas. Therefore, Drinking Water Supplies attempts to provide an action-oriented guidebook on how to develop and implement watershed management strategies to protect surface water supplies from contamination under the constraints of today's economic, legal, institutional, and political conditions. The book succeeds in providing a very clear and useful guide to the process of developing such a strategy. It should be helpful to small and moderate-sized water supply systems and local governments interested in taking action to protect their surface water supply sources.

  13. A new bipolar Qtrim power supply system

    SciTech Connect

    Mi, C.; Bruno, D.; Drozd, J.; Nolan, T.; Orsatti, F.; Heppener, G.; Di Lieto, A.; Schultheiss, C.; Samms, T.; Zapasek, R.; Sandberg, J.

    2015-05-03

    This year marks the 15th run of RHIC (Relativistic Heavy Ion Collider) operations. The reliability of superconducting magnet power supplies is one of the essential factors in the entire accelerator complex. Besides maintaining existing power supplies and their associated equipment, newly designed systems are also required based on the physicist’s latest requirements. A bipolar power supply was required for this year’s main quadruple trim power supply. This paper will explain the design, prototype, testing, installation and operation of this recently installed power supply system.

  14. Public Understanding of Chemistry, ACS National Meeting

    NASA Astrophysics Data System (ADS)

    Gettys, Nancy S.

    2000-06-01

    Three public events for area school-aged children were held on Saturday, March 25, 2000, prior to the opening of the 219th National Meeting of the American Chemical Society. All took place at the Moscone Convention Center in downtown San Francisco. The photographs tell the story: the programs were successful and a good time was had by all. Readers may be encouraged to try these ideas in their own area. If so, the local organizers of Carver Kidvention have additional information at www.scvacs.org/Carver/index.html or contact Howard Peters (Santa Clara Valley Section, ACS), peters4pa@aol.com. Additional photos of the Kidvention event may also be seen as supplemental material.

  15. An ac bridge readout for bolometric detectors

    NASA Technical Reports Server (NTRS)

    Rieke, F. M.; Lange, A. E.; Beeman, J. W.; Haller, E. E.

    1989-01-01

    The authors have developed a bolometer readout circuit which greatly improves the low-frequency stability of bolometric detectors. The circuit uses an ac bias voltage and two matched bolometers and allows stable dc bolometer operation for integration times greater than 10 s. In astronomical applications the readout allows for qualitatively different observation modes (e.g. staring or slow-drift scanning) which are particularly well suited for space observations and for the use of arrays. In many applications the readout can increase sensitivity. The authors present noise spectra for 4He temperature bolometers with no excess noise at frequencies greater than 0.1 Hz. The measured optical responsivity of a bolometer operated with the present readout is the same as that of a bolometer operated with a conventional readout.

  16. Advanced ac powertrain for electric vehicles

    SciTech Connect

    Slicker, J.M.; Kalns, L.

    1985-01-01

    The design of an ac propulsion system for an electric vehicle includes a three-phase induction motor, transistorized PWM inverter/battery charger, microprocessor-based controller, and two-speed automatic transaxle. This system was built and installed in a Mercury Lynx test bed vehicle as part of a Department of Energy propulsion system development program. An integral part of the inverter is a 4-kw battery charger which utilizes one of the bridge transistors. The overall inverter strategy for this configuration is discussed. The function of the microprocessor-based controller is described. Typical test results of the total vehicle and each of its major components are given, including system efficiencies and test track performance results.

  17. Fuzzy efficiency optimization of AC induction motors

    NASA Technical Reports Server (NTRS)

    Jani, Yashvant; Sousa, Gilberto; Turner, Wayne; Spiegel, Ron; Chappell, Jeff

    1993-01-01

    This paper describes the early states of work to implement a fuzzy logic controller to optimize the efficiency of AC induction motor/adjustable speed drive (ASD) systems running at less than optimal speed and torque conditions. In this paper, the process by which the membership functions of the controller were tuned is discussed and a controller which operates on frequency as well as voltage is proposed. The membership functions for this dual-variable controller are sketched. Additional topics include an approach for fuzzy logic to motor current control which can be used with vector-controlled drives. Incorporation of a fuzzy controller as an application-specific integrated circuit (ASIC) microchip is planned.

  18. Modeling of ac dielectric barrier discharge

    SciTech Connect

    Shang, J. S.; Huang, P. G.

    2010-06-15

    The qualitative electrodynamic field of the dielectric barrier discharge in air is studied by a three-component, drift-diffusion plasma model including the Poisson equation of plasmadynamics. The critical media interface boundary conditions independent of the detailed mechanisms of surface absorption, diffusion, recombination, and charge accumulation on electrode or dielectrics are developed from the theory of electromagnetics. The computational simulation duplicates the self-limiting feature of dielectric barrier discharge for preventing corona-to-spark transition, and the numerical results of the breakdown voltage are compared very well with data. According to the present modeling, the periodic electrodynamic force due to charge separation over the electrodes also exerts on alternative directions from the exposed to encapsulated electrodes over a complete ac cycle as experimental observations.

  19. Undergraduate Chemistry Education: Report of an ACS Presidential Symposium

    ERIC Educational Resources Information Center

    Polik, William F.

    2006-01-01

    The American Chemical Society (ACS) Presidential Symposium, Envisioning Undergraduate Chemistry Education in 2015 was organized by the ACS Committee on Professional Training (CPT), in response to the challenge to envision the chemistry enterprise in 2015. The need for more diverse role models at all levels is emphasized, including high school…

  20. 24 CFR Appendices A-C to Subtitle A - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false A Appendices A-C to Subtitle A Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development Appendices A-C to Subtitle A...

  1. 24 CFR Appendices A-C to Subtitle A - [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false A Appendices A-C to Subtitle A Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development Appendices A-C to Subtitle A...

  2. 24 CFR Appendices A-C to Subtitle A - [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false A Appendices A-C to Subtitle A Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development Appendices A-C to Subtitle A...

  3. 24 CFR Appendices A-C to Subtitle A - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false A Appendices A-C to Subtitle A Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development Appendices A-C to Subtitle A...

  4. 24 CFR Appendixes A-C to Subtitle A - [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false A Appendixes A-C to Subtitle A Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development Appendixes A-C to Subtitle A...

  5. Equivalent circuit models for ac impedance data analysis

    NASA Technical Reports Server (NTRS)

    Danford, M. D.

    1990-01-01

    A least-squares fitting routine has been developed for the analysis of ac impedance data. It has been determined that the checking of the derived equations for a particular circuit with a commercially available electronics circuit program is essential. As a result of the investigation described, three equivalent circuit models were selected for use in the analysis of ac impedance data.

  6. Electrostatic coalescence system with independent AC and DC hydrophilic electrodes

    DOEpatents

    Hovarongkura, A. David; Henry, Jr., Joseph D.

    1981-01-01

    An improved electrostatic coalescence system is provided in which independent AC and DC hydrophilic electrodes are employed to provide more complete dehydration of an oil emulsion. The AC field is produced between an AC electrode array and the water-oil interface wherein the AC electrode array is positioned parallel to the interface which acts as a grounded electrode. The emulsion is introduced into the AC field in an evenly distributed manner at the interface. The AC field promotes drop-drop and drop-interface coalescence of the water phase in the entering emulsion. The continuous oil phase passes upward through the perforated AC electrode array and enters a strong DC field produced between closely spaced DC electrodes in which small dispersed droplets of water entrained in the continuous phase are removed primarily by collection at hydrophilic DC electrodes. Large droplets of water collected by the electrodes migrate downward through the AC electrode array to the interface. All phase separation mechanisms are utilized to accomplish more complete phase separation.

  7. A Hyperactive Transposase of the Maize Transposable Element Activator (Ac)

    PubMed Central

    Lazarow, Katina; Du, My-Linh; Weimer, Ruth; Kunze, Reinhard

    2012-01-01

    Activator/Dissociation (Ac/Ds) transposable elements from maize are widely used as insertional mutagenesis and gene isolation tools in plants and more recently also in medaka and zebrafish. They are particularly valuable for plant species that are transformation-recalcitrant and have long generation cycles or large genomes with low gene densities. Ac/Ds transposition frequencies vary widely, however, and in some species they are too low for large-scale mutagenesis. We discovered a hyperactive Ac transposase derivative, AcTPase4x, that catalyzes in the yeast Saccharomyces cerevisiae 100-fold more frequent Ds excisions than the wild-type transposase, whereas the reintegration frequency of excised Ds elements is unchanged (57%). Comparable to the wild-type transposase in plants, AcTPase4x catalyzes Ds insertion preferentially into coding regions and to genetically linked sites, but the mutant protein apparently has lost the weak bias of the wild-type protein for insertion sites with elevated guanine–cytosine content and nonrandom protein-DNA twist. AcTPase4x exhibits hyperactivity also in Arabidopsis thaliana where it effects a more than sixfold increase in Ds excision relative to wild-type AcTPase and thus may be useful to facilitate Ac/Ds-based insertion mutagenesis approaches. PMID:22562933

  8. Operation of AC Adapters Visualized Using Light-Emitting Diodes

    ERIC Educational Resources Information Center

    Regester, Jeffrey

    2016-01-01

    A bridge rectifier is a diamond-shaped configuration of diodes that serves to convert alternating current(AC) into direct current (DC). In our world of AC outlets and DC electronics, they are ubiquitous. Of course, most bridge rectifiers are built with regular diodes, not the light-emitting variety, because LEDs have a number of disadvantages. For…

  9. 40 CFR Appendixes A-C to Part 403 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 29 2011-07-01 2009-07-01 true A Appendixes A-C to Part 403 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GENERAL PRE-TREAT-MENT REGULATIONS FOR EXIST-ING AND NEW SOURCES OF POLLUTION Appendixes A-C to Part 403...

  10. 40 CFR Appendixes A-C to Part 403 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true A Appendixes A-C to Part 403 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GENERAL PRE-TREAT-MENT REGULATIONS FOR EXIST-ING AND NEW SOURCES OF POLLUTION Appendixes A-C to Part 403...

  11. ACS Internal CTE Monitor and Short Darks

    NASA Astrophysics Data System (ADS)

    Ogaz, Sara

    2012-10-01

    This is a continuation of Program 12386 and is to be executed once a cycle for internal CTE and short darks, respectively.INTERNAL CTE MONITOR:The charge transfer efficiency {CTE} of the ACS CCD detectors will decline as damage due to on-orbit radiation exposure accumulates. This degradation will be monitored once a cycle to determine the useful lifetime of the CCDs. All the data for this program is acquired using internal targets {lamps} only, so all of the exposures should be taken during Earth occultation time {but not during SAA passages}. This program emulates the ACS pre-flight ground calibration and post-launch SMOV testing {program 8948}, so that results from each epoch can be directly compared. Extended Pixel Edge Response {EPER} data will be obtained over a range of signal levels for the Wide Field Channel {WFC}. The signal levels are 125, 500, 1620, 5000, 10000, and 60000 electrons at gain 2.Since Cycle 18, this monitoring program was reduced {compared to 11881} considering that there is also an external CTE monitoring program.SHORT DARKS:To improve the pixel-based CTE model at signals below 10 DN, short dark frames are needed to obtain a statistically useful sample of clean, warm pixel trails. This program obtains a set of dark frames for each of the following exposure times: 66 s {60 s for some subarrays} and 339 s. These short darks and the 1040 s darks obtained from the CCD Daily Monitor will sample warm and hot pixels over logarithmically increasing brightness. Subarray short darks were newly added in Cycle 19 to study CTE tails in different subarray readout modes.

  12. ACS Internal CTE Monitor and Short Darks

    NASA Astrophysics Data System (ADS)

    Ogaz, Sara

    2013-10-01

    This is a continuation of Program 13156 and is to be executed once a cycle for internal CTE and short darks, respectively.INTERNAL CTE MONITOR:The charge transfer efficiency {CTE} of the ACS CCD detectors will decline as damage due to on-orbit radiation exposure accumulates. This degradation will be monitored once a cycle to determine the useful lifetime of the CCDs. All the data for this program is acquired using internal targets {lamps} only, so all of the exposures should be taken during Earth occultation time {but not during SAA passages}. This program emulates the ACS pre-flight ground calibration and post-launch SMOV testing {program 8948}, so that results from each epoch can be directly compared. Extended Pixel Edge Response {EPER} data will be obtained over a range of signal levels for the Wide Field Channel {WFC}. The signal levels are 125, 500, 1620, 5000, 10000, and 60000 electrons at gain 2.Since Cycle 18, this monitoring program was reduced {compared to 11881} considering that there is also an external CTE monitoring program.SHORT DARKS:To improve the pixel-based CTE model at signals below 10 DN, short dark frames are needed to obtain a statistically useful sample of clean, warm pixel trails. This program obtains a set of dark frames for each of the following exposure times: 66 s {60 s for some subarrays} and 339 s. These short darks and the 1040 s darks obtained from the CCD Daily Monitor will sample warm and hot pixels over logarithmically increasing brightness. Subarray short darks were added in Cycle 19 to study CTE tails in different subarray readout modes.

  13. Preliminary Geologic Mapping of the Ac-S-1 Hemisphere of Ceres from NASA's Dawn Mission

    NASA Astrophysics Data System (ADS)

    Mest, S. C.; Williams, D. A.; Buczkowski, D. L.; Scully, J. E. C.; Crown, D. A.; Yingst, R. A.; Jaumann, R.; Russell, C. T.; Raymond, C. A.

    2015-10-01

    NASA's Dawn spacecraft [1], launched in September 2007, spent ~1 year (2011-2012) investigating Vesta and recently (March 6, 2015) arrived at dwarf planet Ceres. The first images of Ceres' surface were acquired by Dawn's Framing Camera (FC) [2] as it made optical navigation and rotation characterization observations during the Approach phase. The Dawn Science Team will conduct a geological mapping campaign at Ceres during the Nominal Mission, which will include iterative mapping using data obtained during each orbital phase. Iterative geologic mapping was previously successfully conducted during Dawn's mission to Vesta [3,4]. This abstract describes the preliminary geologic mapping results for quadrangle Ac-S-1 (55-90°N, 0-360°E), the northern hemisphere of Ceres.

  14. A Passive EMI Filter with Access to the Ungrounded Motor Neutral Line-Its Effect on Eliminating Leakage Current from the Inverter Heat Sink-

    NASA Astrophysics Data System (ADS)

    Doumoto, Takafumi; Akagi, Hirofumi

    This paper deals with a leakage current flowing out of the heat sink of a voltage-source PWM inverter. The heat-sink leakage current is caused by a steep change in the common-mode voltage produced by the inverter. It flows through parasitic capacitors between the heat sink and power semiconductor devices when no EMI filter is connected. Experimental results reveal that the heat-sink leakage current flows not into the supply side, but into the motor side. These understandings succeed in describing an equivalent common-mode circuit taking the parasitic capacitors into account. The authors have proposed a passive EMI filter that is unique in access to the ungrounded motor neutral line. It is discussed from this equivalent circuit that the passive EMI filter is effective in preventing the leakage current from flowing. Moreover, installation of another small-sized common-mode inductor at the ac side of the diode rectifier prevents the leakage current from flowing into the supply side. Experimental results obtained from a 200-V, 3.7-kW laboratory system confirm the effectiveness and viability of the EMI filter.

  15. Tribological behavior of electron beam D6ac weldment

    NASA Astrophysics Data System (ADS)

    Wu, Shyh-Chi; Tseng, Kuang-Hung; Wen, Hua-Chiang; Wu, Ming-Jhang; Chou, Chang-Pin

    2013-01-01

    A flow formed D6ac steel tubing was joined using electron beam (EB) welding. Thereafter, the EB weldments were treated by tempering at temperatures of 450 °C and 550 °C. After tempering, the microstructural features, mechanical properties, and tribological characteristics of the EB D6ac weldment were studied. This study used a scratch test to evaluate the sliding wear resistance of the tempered weldment. Results indicate that the tempering softens the microstructure by reducing the dislocation density of the flow formed D6ac steel. For the 450 °C/2 h/air cooling tempering treated D6ac steel, the fracture toughness of the EB weldment can be significantly improved. The tribological behavior of the tempered D6ac weldment depended on the tempered microstructures.

  16. Characteristics of ? multifilamentary wires for a.c. use developed by the bronze process using diffusion barrier techniques

    NASA Astrophysics Data System (ADS)

    Miura, Osuke; Matsumoto, Kaname; Tanaka, Yasuzo; Uno, Naoki

    1996-03-01

    0953-2048/9/3/015/img7 multifilamentary superconducting wires for a.c. use were developed by the bronze method using Cu diffusion barrier techniques. To reduce a.c. losses, the filament diameter was designed to be less than 0953-2048/9/3/015/img8 and the final resistivity of the bronze matrix was increased using a Cu alloy diffusion barrier with the addition of Si and Mn elements around the filaments. As a result, interfilamentary proximity coupling could be prevented until a filament spacing of 0953-2048/9/3/015/img9 and hysteresis losses for the wires reached lower values, from 0953-2048/9/3/015/img10 to 0953-2048/9/3/015/img11 at a magnetic field amplitude of 0.5 T under controlled reaction heat treatment. The perpendicular resistivity of the matrix between the filaments estimated from the coupling loss was about 0953-2048/9/3/015/img12, which was considerably less than the resistivity value of the matrix estimated after the reaction. This was thought to be due to an extreme reduction in Sn concentration between the filaments. Furthermore, a small a.c. coil was fabricated by winding a stranded cable fabricated in this way. The a.c. loss of the coil at 50 Hz in a central magnetic field of 0.5 T was 0953-2048/9/3/015/img13 and the a.c. quench current at 50 Hz was 195 A, which is about 10% lower than the critical current on the load line. This degradation was due to the temperature rise in the cable caused by a.c. loss.

  17. Power supply circuit for an ion engine sequentially operated power inverters

    NASA Technical Reports Server (NTRS)

    Cardwell, Jr., Gilbert I. (Inventor)

    2000-01-01

    A power supply circuit for an ion engine suitable for a spacecraft has a voltage bus having input line and a return line. The power supply circuit includes a pulse width modulation circuit. A plurality of bridge inverter circuits is coupled to the bus and the pulse width modulation circuit. The pulse width modulation circuit generates operating signals having a variable duty cycle. Each bridge inverter has a primary winding and a secondary winding. Each secondary winding is coupled to a rectifier bridge. Each secondary winding is coupled in series with another of the plurality of rectifier bridges.

  18. Sustainable AC/AC hybrid electrochemical capacitors in aqueous electrolyte approaching the performance of organic systems

    NASA Astrophysics Data System (ADS)

    Abbas, Qamar; Babuchowska, Paulina; Frąckowiak, Elżbieta; Béguin, François

    2016-09-01

    A high energy hybrid AC/AC electrochemical capacitor has been realized in aqueous Li2SO4+KI electrolyte mixture. Owing to the redox processes associated with the 2I-/I2 system, the positive electrode operates in narrow potential range and displays high capacity. During prolonged potentiostatic floating at 1.6 V, the hybrid cell demonstrates remarkably stable capacitance and resistance. Analyses by temperature programmed desorption after floating at 1.6 V proved that oxidation of the positive AC electrode is prevented by the use of Li2SO4+KI, which enables the maximum potential of this electrode to be shifted below the water oxidation potential. When charged at 0.2 A g-1 up to U = 1.6 V, the hybrid cell displays a high capacitance of 75 F g-1 (300 F g-1 per mass of one electrode) compared to 47 F g-1 (188 F g-1 per mass of one electrode) for a symmetric cell in Li2SO4. At 0.2 A g-1 up to 1.6 V, the hybrid capacitor in Li2SO4+KI displays an energy density of 26 Wh kg-1 which approaches the energy density of 30.9 Wh kg-1 measured when the same carbon is implemented in a capacitor using TEABF4/ACN electrolyte and charged up to 2.5 V.

  19. HVDC-AC system interaction from AC harmonics. Volume 1. Harmonic impedance calculations. Final report

    SciTech Connect

    Breuer, G D; Chow, J H; Lindh, C B; Miller, N W; Numrich, F H; Price, W W; Turner, A E; Whitney, R R

    1982-09-01

    Improved methods are needed to characterize ac system harmonic behavior for ac filter design for HVDC systems. The purpose of this General Electric Company RP1138 research is to evaluate the present filter design practice and to investigate methods for calculating system harmonic impedances. An overview of ac filter design for HVDC systems and a survey of literature related to filter design have been performed. Two methods for calculating system harmonic impedances have been investigated. In the measurement method, an instrumentation system for measuring system voltage and current has been assembled. Different schemes of using the measurements to calculate system harmonic impedances have been studied. In the analytical method, a procedure to include various operating conditions has been proposed. Computer programs for both methods have been prepared, and the results of the measurement and analytical methods analyzed. A conclusion of the project is that the measurement and analytical methods both provided reasonable results. There are correlations between the measured and analytical results for most harmonics, although there are discrepancies between the assumptions used in the two methods. A sensitivity approach has been proposed to further correlate the results. From the results of the analysis, it is recommended that both methods should be tested further. For the measurement method, more testing should be done to cover different system operating conditions. In the analytical method, more detailed models for representing system components should be studied. In addition, alternative statistical and sensitivity approaches should be attempted.

  20. Inductive gas line for pulsed lasers

    DOEpatents

    Benett, William J.; Alger, Terry W.

    1985-01-01

    A gas laser having a metal inlet gas feed line assembly shaped as a coil, to function as an electrical inductance and therefore high impedance to pulses of electric current applied to electrodes at opposite ends of a discharge tube of a laser, for example. This eliminates a discharge path for the laser through the inlet gas feed line. A ferrite core extends through the coil to increase the inductance of the coil and provide better electric isolation. By elimination of any discharge breakdown through the gas supply, efficiency is increased and a significantly longer operating lifetime of the laser is provided.