Science.gov

Sample records for ac susceptibility measurement

  1. Theoretical analysis on ac susceptibility measurements of superconductor tapes

    NASA Astrophysics Data System (ADS)

    Chen, Du-Xing; Sun, Yue-Ming; Li, Shuo; Fang, Jin

    2017-02-01

    Perpendicular ac susceptibility χ ={χ\\prime}-j{χ\\prime \\prime} of a superconducting long tape defined by magnetic moment and determined inductively by magnetic flux is calculated using Brandt’s technique from a power-law dependence of electric field on sheet current density. The requirements of χ measurements to the experimental setup and procedure are discussed based on the calculation results.

  2. Correlation of AC Loss Data from Magnetic Susceptibility Measurements with YBCO Film Quality (Postprint)

    DTIC Science & Technology

    2012-02-01

    excimer laser operating at the KrF, 248 nm , wavelength. Substrates included LaAlO3 ( 100 ) and SrTiO3 ( 100 ) single crystal substrates as well as buffered...AFRL-RZ-WP-TP-2012-0100 CORRELATION OF AC LOSS DATA FROM MAGNETIC SUSCEPTIBILITY MEASUREMENTS WITH YBCO FILM QUALITY (POSTPRINT) Paul N...CORRELATION OF AC LOSS DATA FROM MAGNETIC SUSCEPTIBILITY MEASUREMENTS WITH YBCO FILM QUALITY (POSTPRINT) 5a. CONTRACT NUMBER In-house 5b. GRANT

  3. Design of Low Temperature AC Susceptibility Measurement Scheme for Molecular Magnets

    NASA Astrophysics Data System (ADS)

    Korenblit, Simcha; Moon, Byoung; Lee, Yoonseok; Sultan, Reza

    2006-03-01

    AC susceptibility is one of the most important physical properties in many materials such as magnetic materials and superconductors. Although there are many commercial AC susceptibility measurement systems which cover a broad range of temperatures, it is still a daunting task to extend their measurement range into the low millikelvins. We are currently developing a low temperature AC susceptometer for the mK range. As a part of this effort, we have developed a versatile low-cost computer controlled coil-winder to make various types of coils. We have designed primary and secondary coils and wound them using the machine, and performed characterization of the AC susceptometer. In this presentation, I will explain the basics of magnetic susceptibility, its measurement, design considerations for building an AC magnetic susceptometer, and discuss the details of an actual apparatus designed and realized by the authors.

  4. AC Magnetic Properties of Large Volume of Water — Susceptibility Measurement in Unshielded Environment

    NASA Astrophysics Data System (ADS)

    Tsukada, Keiji; Kiwa, Toshihiko; Masuda, Yuuki

    2006-10-01

    To investigate the effect of low-frequency magnetic-field exposure of a human body, the low-frequency AC magnetic property of a large volume of water was measured by low-frequency magnetic field exposure (from 50 Hz to 1.2 kHz). The results indicate that the AC magnetic property of water is due to diamagnetism in the low-frequency range. The phase between the main magnetic field and the generated magnetic field remained constant at about 180°. Results were not affected by conductivity or pH. Moreover, the magnetic-field strength from water showed a susceptibility frequency dependence proportional to the frequency above approximately 400 Hz. Because of the incremental effects of susceptibility, the magnetic field from water was measured using a conventional magnetic sensor (magnetic resistive; MR) in an unshielded environment.

  5. Simple uniaxial pressure device for ac-susceptibility measurements suitable for closed cycle refrigerator system.

    PubMed

    Arumugam, S; Manivannan, N; Murugeswari, A

    2007-06-01

    A simple design of the uniaxial pressure device for the measurement of ac-susceptibility at low temperatures using closed cycle refrigerator system is presented for the first time. This device consists of disc micrometer, spring holder attachment, uniaxial pressure cell, and the ac-susceptibility coil wound on stycast bobbin. It can work under pressure till 0.5 GPa and at the temperature range of 30-300 K. The performance of the system at ambient pressure is tested and calibrated with standard paramagnetic salts [Gd(2)O(3), Er(2)O(3), and Fe(NH(4)SO(4))(2)6H(2)O], Fe(3)O(4), Gd metal, Dy metal, superconductor (YBa(2)Cu(3)O(7)), manganite (La(1.85)Ba(0.15)MnO(3)), and spin glass material (Pr(0.8)Sr(0.2)MnO(3)). The performance of the uniaxial pressure device is demonstrated by investigating the uniaxial pressure dependence of La(1.85)Ba(0.15)MnO(3) single crystal with P||c axis. The Curie temperature (T(c)) decreases as a function of pressure with P||c axis (dT(c)dP(||c axis)=-11.65 KGPa) up to 46 MPa. The design is simple, is user friendly, and does not require pressure calibration. Measurement can even be made on thin and small size oriented crystals. The failure of the coil is remote under uniaxial pressure. The present setup can be used as a multipurpose uniaxial pressure device for the measurement of Hall effect and thermoelectric power with a small modification in the pressure cell.

  6. Simple uniaxial pressure device for ac-susceptibility measurements suitable for closed cycle refrigerator system

    NASA Astrophysics Data System (ADS)

    Arumugam, S.; Manivannan, N.; Murugeswari, A.

    2007-06-01

    A simple design of the uniaxial pressure device for the measurement of ac-susceptibility at low temperatures using closed cycle refrigerator system is presented for the first time. This device consists of disc micrometer, spring holder attachment, uniaxial pressure cell, and the ac-susceptibility coil wound on stycast bobbin. It can work under pressure till 0.5GPa and at the temperature range of 30-300K. The performance of the system at ambient pressure is tested and calibrated with standard paramagnetic salts [Gd2O3, Er2O3, and Fe(NH4SO4)26H2O], Fe3O4, Gd metal, Dy metal, superconductor (YBa2Cu3O7), manganite (La1.85Ba0.15MnO3), and spin glass material (Pr0.8Sr0.2MnO3). The performance of the uniaxial pressure device is demonstrated by investigating the uniaxial pressure dependence of La1.85Ba0.15MnO3 single crystal with P ‖c axis. The Curie temperature (Tc) decreases as a function of pressure with P ‖c axis (dTc/dP‖caxis=-11.65K/GPa) up to 46MPa. The design is simple, is user friendly, and does not require pressure calibration. Measurement can even be made on thin and small size oriented crystals. The failure of the coil is remote under uniaxial pressure. The present setup can be used as a multipurpose uniaxial pressure device for the measurement of Hall effect and thermoelectric power with a small modification in the pressure cell.

  7. Hydrostatic Pressure Study on 3-K Phase Superconductivity in Sr2RuO4-Ru Eutectic Crystals by AC Magnetic Susceptibility Measurements

    NASA Astrophysics Data System (ADS)

    Yaguchi, Hiroshi; Watanabe, Hiromichi; Sakaue, Akira

    2012-12-01

    We have investigated the effect of hydrostatic pressure on 3-K phase superconductivity in Sr2RuO4-Ru eutectic crystals by means of AC magnetic susceptibility measurements. We have found that the application of hydrostatic pressure suppresses the superconducting transition temperature Tc of the 3-K phase with a pressure coefficient of dTc/dP ≈ -0.2 K/GPa, similar to the case of the 1.5-K phase. We have also observed that the effect of hydrostatic pressure on the 3-K phase seems to be elastic whilst that of uniaxial pressure is plastic.

  8. AC-Susceptibility and Ultrasonic Attenuation Measurements of Vortex Dynamics in the Vicinity of the Peak Effect in V-Ti Alloys - Multicriticality Revisited

    NASA Astrophysics Data System (ADS)

    Dimitrov, I. K.

    2005-03-01

    In-situ SANS and ac-susceptibility measurements have provided evidence for a first-order Bragg glass transition into a disordered vortex state in a Nb single crystal. This transition manifests itself in the peak effect (PE) in the critical current density, widely believed to be associated with the sudden softening of the vortex lattice. Subsequent studies mapping the full phase diagram in the same sample have suggested the existence of four distinct phase boundaries meeting at a single multicritical point (MCP). The natures of the transition lines combined with simple thermodynamic requirements suggest that the MCP is a bicritical point. This would rule out either the bulk transition line Tc2(T) or the surface superconducting transition Hc3(T) as being related to the MCP. Mutual inductance magnetic ac-susceptibility and ultrasonic attenuation measurements in V-21at.%Ti have unequivocally established the presence of a PE in this alloy. The H-T phase diagram for this sample will be presented and vortex dynamics in the vicinity of the PE will be discussed. We are indebted to Prof. Shapira of Tufts University for providing us with the sample. This work was supported by the NSF under Grant No. DMR-0406626.

  9. Vortex dynamics and irreversibility line in optimally doped SmFeAsO0.8F0.2 from ac susceptibility and magnetization measurements

    NASA Astrophysics Data System (ADS)

    Prando, G.; Carretta, P.; de Renzi, R.; Sanna, S.; Palenzona, A.; Putti, M.; Tropeano, M.

    2011-05-01

    Ac susceptibility and static magnetization measurements were performed in the optimally doped SmFeAsO0.8F0.2 superconductor. The field-temperature phase diagram of the superconducting state was drawn, and, in particular, the features of the flux lines were derived. The dependence of the intragrain depinning energy on the magnetic field intensity was derived in the thermally activated flux-creep framework, enlightening a typical 1/H dependence in the high-field regime. The intragrain critical current density was extrapolated in the zero-temperature and zero-magnetic-field limit, showing a remarkably high value Jc0(0)~2×107 A/cm2, which demonstrates that this material is rather interesting for potential future technological applications.

  10. A cluster-glass magnetic state in R5Pd2 (R = Ho, Tb) compounds evidenced by AC-susceptibility and neutron scattering measurements

    NASA Astrophysics Data System (ADS)

    Gubkin, A. F.; Sherstobitova, E. A.; Terentyev, P. B.; Hoser, A.; Baranov, N. V.

    2013-06-01

    AC- and DC-susceptibility, high-field magnetization and neutron diffraction measurements have been performed in order to study the magnetic state of R5Pd2 (R = Ho, Tb) compounds. The results show that both compounds undergo cluster-glass freezing upon cooling below Tf. According to the neutron diffraction a long-range magnetic order is absent down to 2 K and magnetic clusters with short-range incommensurate antiferromagnetic correlations exist not only below Tf but also in a wide temperature range above the freezing temperature (at least up to 2Tf). A complex cluster-glass magnetic state existing in Ho5Pd2 and Tb5Pd2 down to low temperatures results in rather complicated magnetization behavior in DC and AC magnetic fields. Such an unusual magnetic state in compounds with a high rare-earth concentration may be associated with the layered type of their crystal structure and with substantial atomic disorder, which results in frustrations in the magnetic subsystem.

  11. Ac magnetic susceptibility study of in vivo nanoparticle biodistribution

    NASA Astrophysics Data System (ADS)

    Gutiérrez, L.; Mejías, R.; Barber, D. F.; Veintemillas-Verdaguer, S.; Serna, C. J.; Lázaro, F. J.; Morales, M. P.

    2011-06-01

    We analysed magnetic nanoparticle biodistribution, before and after cytokine conjugation, in a mouse model by ac susceptibility measurements of the corresponding resected tissues. Mice received repeated intravenous injections of nanoparticle suspension for two weeks and they were euthanized 1 h after the last injection. In general, only 10% of the total injected nanoparticles after multiple exposures were found in tissues. The rest of the particles may probably be metabolized or excreted by the organism. Our findings indicate that the adsorption of interferon to DMSA-coated magnetic nanoparticles changes their biodistribution, reducing the presence of nanoparticles in lungs and therefore their possible toxicity. The specific targeting of the particles to tumour tissues by the use of an external magnetic field has also been studied. Magnetic nanoparticles were observed by transmission electron microscopy in the targeted tissue and quantified by ac magnetic susceptibility.

  12. AC resistance measuring instrument

    DOEpatents

    Hof, P.J.

    1983-10-04

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument. 8 figs.

  13. AC Resistance measuring instrument

    DOEpatents

    Hof, Peter J.

    1983-01-01

    An auto-ranging AC resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an AC excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance. After the auto-ranging and auto-compensation functions are complete, the microprocessor calculates the resistance of the load from the selected range resistance, the excitation signal, and the load voltage signal, and displays of the measured resistance on a digital display of the instrument.

  14. Field-dependence of AC susceptibility in titanomagnetites

    USGS Publications Warehouse

    Jackson, M.; Moskowitz, B.; Rosenbaum, J.; Kissel, Catherie

    1998-01-01

    AC susceptibility measurements as a function of field amplitude Hac and of frequency show a strong field dependence for a set of synthetic titanomagnetites (Fe3-xTixO4) and for certain basalts from the SOH-1 Hawaiian drill hole and from Iceland. In-phase susceptibility is constant below fields of about 10-100 A/m, and then increases by as much as a factor of two as Hsc is increased to 2000 A/m. Both the initial field-independent susceptibilities and field-dependence of susceptibility are systematically related to composition: initial susceptibility is 3 SI for a single-crystal sphere of TMO (x = 0) and decreases with increasing titanium content; field-dependence is nearly zero for TM0 and increases systematically to a maximum near TM60 (x = 0.6). This field dependence can in some cases be mistaken for frequency dependence, and leaf to incorrect interpretations of magnetic grain size and composition when titanomagnetite is present.

  15. Automated ac galvanomagnetic measurement system

    NASA Technical Reports Server (NTRS)

    Szofran, F. R.; Espy, P. N.

    1985-01-01

    An automated, ac galvanomagnetic measurement system is described. Hall or van der Pauw measurements in the temperature range 10-300 K can be made at a preselected magnetic field without operator attendance. Procedures to validate sample installation and correct operation of other system functions, such as magnetic field and thermometry, are included. Advantages of ac measurements are discussed.

  16. Spectroscopic AC Susceptibility Imaging (sASI) of Magnetic Nanoparticles.

    PubMed

    Ficko, Bradley W; Nadar, Priyanka M; Diamond, Solomon G

    2015-02-01

    This study demonstrates a method for alternating current (AC) susceptibility imaging (ASI) of magnetic nanoparticles (mNPs) using low cost instrumentation. The ASI method uses AC magnetic susceptibility measurement to create tomographic images using an array of drive coils, compensation coils and fluxgate magnetometers. Using a spectroscopic approach in conjunction with ASI, a series of tomographic images can be created for each frequency measurement and is termed sASI. The advantage of sASI is that mNPs can be simultaneously characterized and imaged in a biological medium. System calibration was performed by fitting the in-phase and out-of-phase susceptibility measurements of an mNP sample with a hydrodynamic diameter of 100 nm to a Brownian relaxation model (R(2) = 0.96). Samples of mNPs with core diameters of 10 and 40 nm and a sample of 100 nm hydrodynamic diameter were prepared in 0.5 ml tubes. Three mNP samples were arranged in a randomized array and then scanned using sASI with six frequencies between 425 and 925 Hz. The sASI scans showed the location and quantity of the mNP samples (R(2) = 0.97). Biological compatibility of the sASI method was demonstrated by scanning mNPs that were injected into a pork sausage. The mNP response in the biological medium was found to correlate with a calibration sample (R(2) = 0.97, p <0.001). These results demonstrate the concept of ASI and advantages of sASI.

  17. Spectroscopic AC susceptibility imaging (sASI) of magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Ficko, Bradley W.; Nadar, Priyanka M.; Diamond, Solomon G.

    2015-02-01

    This study demonstrates a method for alternating current (AC) susceptibility imaging (ASI) of magnetic nanoparticles (mNPs) using low cost instrumentation. The ASI method uses AC magnetic susceptibility measurements to create tomographic images using an array of drive coils, compensation coils and fluxgate magnetometers. Using a spectroscopic approach in conjunction with ASI, a series of tomographic images can be created for each frequency measurement set and is termed sASI. The advantage of sASI is that mNPs can be simultaneously characterized and imaged in a biological medium. System calibration was performed by fitting the in-phase and out-of-phase susceptibility measurements of an mNP sample with a hydrodynamic diameter of 100 nm to a Brownian relaxation model (R2=0.96). Samples of mNPs with core diameters of 10 and 40 nm and a sample of 100 nm hydrodynamic diameter were prepared in 0.5 ml tubes. Three mNP samples were arranged in a randomized array and then scanned using sASI with six frequencies between 425 and 925 Hz. The sASI scans showed the location and quantity of the mNP samples (R2=0.97). Biological compatibility of the sASI method was demonstrated by scanning mNPs that were injected into a pork sausage. The mNP response in the biological medium was found to correlate with a calibration sample (R2=0.97, p<0.001). These results demonstrate the concept of ASI and advantages of sASI.

  18. Magnetic ordering in UCoNiSi2 and UCoCuSi2 studied by ac-susceptibility and neutron-diffraction measurements

    NASA Astrophysics Data System (ADS)

    Kuznietz, Moshe; Pinto, Haim; Melamud, Mordechai

    1994-05-01

    Polycrystalline samples of intermediate solid solutions of the UM2Si2 compounds (M=Co,Ni,Cu), namely UCoNiSi2 and UCoCuSi2, were prepared and were found to have body-centered tetragonal ThCr2Si2-type crystallographic structure. In UCoNiSi2 ac susceptibility indicates a single antiferromagnetic (AF) transition at TN=115±5 K, confirmed by neutron-diffraction observation of the AF-I structure down to 10 K (with uranium moments of 1.6±0.2μB, along the tetragonal c axis). In UCoCuSi2 ac susceptibility indicates ferromagnetic transition at TC=107±5 K, and implies an AF transition at lower temperature, confirmed by the AF-I structure, observed in neutron diffraction below T0=95±5 K down to 10 K (with uranium moments of 1.6±0.1μB, along the c axis). The magnetic properties are discussed in comparison with UM2X2 and U(M,M')2X2 materials (X=Si,Ge).

  19. Investigation of magnetic spin glass property in La{sub 0.5}Bi{sub 0.5}MnO{sub 3} sample using non-linear AC susceptibility measurements

    SciTech Connect

    Kumar, Punith V. Manju, M. R. Dayal, Vijaylakshmi

    2014-04-24

    We present a comprehensive study on origin of Spin Glass (SG) property in polycrystalline La{sub 0.5}Bi{sub 0.5}MnO{sub 3} perovskite oxide using linear and higher order ac susceptibility (χ) measurements. The third order harmonic susceptibility (χ{sub 3}) vs. temperature (K) with varying magnetic fields from 0.95 to 9.45 Oe and the divergence in their χ{sub 3} (max) allows us to infer the SG behavior occurring in the sample possibly due to co-operative freezing of the spins.

  20. Power-law resistivity, magnetic relaxation and ac susceptibility

    SciTech Connect

    Gilchrist, J.; van der Beek, C.J.

    1994-07-01

    The nonlinear diffusion of magnetic flux into a superconducting sample can be studied by measuring the relaxation of the magnetisation after application of a step field or by measuring the ac susceptibility, {chi}{sub 1} and its third harmonic, {chi}{sub 3}, or preferably both methods covering different time scales. Each has been analysed recently for a field-cooled sample of a material whose creep activation energy depends logarithmically on current density, J corresponding to a power-law relation between electric field, E and J. Here, results are compared, using a universal scaling depth. Maximum {chi}{sub 1}{double_prime} {vert_bar}{chi}{sub 3}{vert_bar} and values occur, and also the magnetisation has relaxed to half its initial value when the scaling depth is comparable to the sample half-thickness.

  1. ac susceptibility study of a magnetite magnetic fluid

    NASA Astrophysics Data System (ADS)

    Ayala-Valenzuela, O. E.; Matutes-Aquino, J. A.; Galindo, J. T. Elizalde; Botez, C. E.

    2009-04-01

    Magnetite nanometric powder was synthesized from metal salts using a coprecipitation technique. The powders were used to produce magnetic fluid via a peptization method, with hydrocarbon Isopar M as liquid carrier and oleic acid as surfactant. The complex magnetic susceptibility χ =χ'+iχ″ was measured as a function of temperature T in steps of 2.5 K from 3 to 298 K for frequencies ranging from f =10 to 10 000 Hz. The magnetic fluid real and imaginary components of the ac susceptibility show a prominent maximum at temperatures that increase with the measuring frequency, which is attributed to a spin-glass-like behavior. The peak temperature Tp1 of χ″ depends on f following the Vogel-Fulcher law f =f0 exp[E /kB(Tp1-T0)], where f0 and E are positive constants and T0 is a parameter related to particle interactions. There is another kind of peak temperature, Tp2, in the loss factor tan δ =χ″/χ' which is related to a magnetic aftereffect. The peak temperature Tp2 is far less than Tp1 and shows an Arrhenius-type dependence on f.

  2. ac-resistance-measuring instrument

    SciTech Connect

    Hof, P.J.

    1981-04-22

    An auto-ranging ac resistance measuring instrument for remote measurement of the resistance of an electrical device or circuit connected to the instrument includes a signal generator which generates an ac excitation signal for application to a load, including the device and the transmission line, a monitoring circuit which provides a digitally encoded signal representing the voltage across the load, and a microprocessor which operates under program control to provide an auto-ranging function by which range resistance is connected in circuit with the load to limit the load voltage to an acceptable range for the instrument, and an auto-compensating function by which compensating capacitance is connected in shunt with the range resistance to compensate for the effects of line capacitance.

  3. Susceptibilities of Helicoverpa zea and Heliothis virescens (Lepidoptera: Noctuidae) populations to Cry1Ac insecticidal protein.

    PubMed

    Ali, M I; Luttrell, R G; Young, S Y

    2006-02-01

    Susceptibilities of bollworm, Helicoverpa zea (Boddie) and tobacco budworm, Heliothis virescens (F.) to Cry1Ac were measured via a diet-incorporated assay with MPV II at the University of Arkansas during 2002-2004. Lethal concentration-mortality (LC50) estimates of five laboratory, seven laboratory-cross, and 10 field populations of H. virescens varied 12-fold. Pooled susceptibilities of H. virescens across all laboratory and field populations varied five-fold. The LC50 estimates for H. virescens were higher than those reported by previous research before the introduction of transgenic crops. However, the ratio of susceptibility of laboratory and field populations was similar, suggesting no change in overall species susceptibility. Individual LC50 estimates of five laboratory, nine laboratory-cross, and 57 field populations of H. zea varied over 130-fold. Pooled susceptibilities across laboratory and field populations varied widely. Among the field populations, colonies from non-Bacillus thuringiensis (Bt) crops were generally more susceptible than those from Bt crops. Across the Bt crops expressing Cry protein, colonies from Bollgard (Monsanto Company) cotton had lower susceptibility to CrylAc than those from Bt corn and those from non-Bt crops.

  4. AC Susceptibilities in Zn Doped (Bi,Pb)(Sr,Ba):2223 Superconductor

    NASA Astrophysics Data System (ADS)

    Pop, V.

    AC susceptibility measurements as a function of temperature and amplitude of alternative magnetic field have been carried out on the samples (Bi,Pb)(Sr,Ba):2223 with Cu substituted by Zn at a concentration of x = 0.00, 0.02 and 0.05. The decrease of intergrain and intragrain critical temperatures with increasing x is in agreement with the increase of the residual resistivity. Using Muller critical state model and the linear dependence of Tp for the maximum of imaginary χ''(T) peak, as a function of AC field amplitude, the intergranular pining force density was obtained. The intergrain properties are more influenced than the intragrain ones.

  5. Superconductivity and itinerant ferromagnetism of Y9Co7 probed by ac susceptibility.

    PubMed

    Gordon, R T; Vannette, M D; Strychalska, J; Klimczuk, T; Cava, R J; Prozorov, R

    2016-04-27

    The ac magnetic susceptibility of a single crystal sample of the compound Y9Co7 has been measured in applied dc fields ranging from 0-6.7 kOe by utilizing a tunnel diode resonator circuit. In agreement with previous measurements on this material, a superconducting transition has been observed to occur at T(SC)≈2.5 K. A broad maximum has been observed in the zero field susceptibility measurements from 2.5 K  <  T  <  8 K and its behavior with applied dc magnetic fields is consistent with that of the itinerant ferromagnet ZrZn2, which supports previous claims of itinerant ferromagnetism in this compound. The susceptibility has also been measured as a function of applied magnetic field and the results indicate that the actual Curie temperature for this system is higher than that suggested by previous reports based on Arrott plots constructed from dc magnetization.

  6. Whole tissue AC susceptibility after superparamagnetic iron oxide contrast agent administration in a rat model

    NASA Astrophysics Data System (ADS)

    Lázaro, Francisco José; Gutiérrez, Lucía; Rosa Abadía, Ana; Soledad Romero, María; López, Antonio; Jesús Muñoz, María

    2007-04-01

    A magnetic AC susceptibility characterisation of rat tissues after intravenous administration of superparamagnetic iron oxide (Endorem ®), at the same dose as established for Magnetic Resonance Imaging (MRI) contrast enhancement in humans, has been carried out. The measurements reveal the presence of the contrast agent as well as that of physiological ferritin in liver and spleen while no traces have been magnetically detected in heart and kidney. This preliminary work opens suggestive possibilities for future biodistribution studies of any type of magnetic carriers.

  7. Spatial variations in ac susceptibility and microstructure for the YBa2Cu3O(7-x) superconductor and their correlation with room-temperature ultrasonic measurements

    NASA Technical Reports Server (NTRS)

    Roth, Don J.; Deguire, Mark R.; Dolhert, Leonard E.; Hepp, Aloysius F.

    1991-01-01

    The spatial (within-sample) uniformity of superconducting behavior and microstructure in YBa2Cu3O(7-x) specimens over the pore fraction range of 0.10 to 0.25 was examined. The viability of using a room-temperature, nondestructive characterization method (ultrasonic velocity imaging) to predict spatial variability was determined. Spatial variations in superconductor properties were observed for specimens containing 0.10 pore fraction. An ultrasonic velocity image constructed from measurements at 1 mm increments across one such specimen revealed microstructural variation between edge and center locations that correlated with variations in alternating-current shielding and loss behavior. Optical quantitative image analysis on sample cross-sections revealed pore fraction to be the varying microstructural feature.

  8. Magnetic AC susceptibility study of the cobalt segregation process in melt-spun Cu-Co alloys

    NASA Astrophysics Data System (ADS)

    López, A.; Lázaro, F. J.; von Helmolt, R.; García-Palacios, J. L.; Wecker, J.; Cerva, H.

    1998-08-01

    Temperature and frequency-dependent AC susceptibility has been used to characterize Cu 90Co 10 melt-spun ribbons, about 15 μm thick, in order to see to what extent this technique yields information about the segregation of cobalt in this alloy. The interpretation of the results includes, as a prerequisite, a transmission electron microscopy (TEM) characterization and makes use of previous field-dependent magnetization data on the same samples. Due to their different dynamical magnetic properties, the large intergrain precipitates, the small intragrain aggregates and the remaining Cu-Co solid solution, previously detected in these alloys, are independently observed by AC susceptibility as ferromagnetic, superparamagnetic and spin-glass species. Contrary to other, mostly local, microstructural characterization techniques of use with nanostructured materials, the AC susceptibility yields information about the whole sample. Furthermore, unlike the measurement of the temperature-dependent magnetization which is the magnetic technique mostly used until now, the results are basically independent of the thermal history. The correlation between microstructure and magnetic properties is illustrated by a scheme which includes magnetization, AC susceptibility and TEM data.

  9. AC susceptibility of grains and matrix for high-T c superconductors

    NASA Astrophysics Data System (ADS)

    Chen, D.-X.; Sanchez, A.; Puig, T.; Martinez, L. M.; Muñoz, J. S.

    1990-07-01

    Several 123-YBCO superconducting samples cut from the same pellet have been studied by measuring AC susceptibility at 77 K as a function of the applied field amplitude Hm. Two contributions from inter- and intragranular supercurrents to the susceptibility are clearly observed with Hm up to 30 kA/m. The partial susceptibilities for the matrix, χ m and χ m, come from the intergranular supercurrents and show a systematic sample thickness dependence. Although Kim's critical-state model explains the essential features of these susceptibilities and can be used to determine Jc as a function of local internal field Hi, the actual Jc( Hi) is more complex, with a concave segment at low fields. The partial susceptibilities for the grains, χ g and χ g, do not have sample thickness dependence, and the maximum χ g is much lower than predicted by the critical-state model. This is shown to be related to the bee-waist shape of the hysteresis loop, which is due to the existence of a lower critical field. The lower critical fields of the grains ( Hc1g) and the matrix ( Hc1m), and the effective volume fraction of the grains (⨍ g) are determined on the basis of the critical-state model. The lower limit for Hc1g is found to be around 4 kA/m, but Hc1m cannot be detected for Hm as low as 40 A/m. The results have been compared with some published weak-link models. A grain-cluster model is proposed for solving the problem of over high ⨍ g.

  10. AC susceptibility and EPR investigations of superspin dynamics in magnetite nanoparticles

    NASA Astrophysics Data System (ADS)

    Price, Alex D.

    In this investigation we use two complementary techniques to distinguish between superparamagnetic blocking (SPB) and superspin-glass (SSG) freezing phenomena in magnetite nanoparticles. While these manifestations of the superspin dynamics are fundamentally different, they have similar "signatures", especially in dc-magnetization experiments. Even if ac-susceptibility measurements are employed, careful use of mathematical models to analyze the data are needed to uncover which type of phenomena (SPB or SSG freezing) occurs within the material. Yet, by utilizing electron paramagnetic resonance (EPR) on a 10 nm Fe3O4 nano-powder as well as on a ferrofluid (based on the same nanoparticle ensemble) we found a very distinct difference in the absorption spectra between the two samples, which indicates markedly different EPR signatures from SPB and SSG freezing behaviors.

  11. Ac Permeability Measurement for Inter- and Intragrain Critical Current Densities in Oxide Superconductors

    NASA Astrophysics Data System (ADS)

    Matsushita, Teruo; Ni, Baorong

    1989-03-01

    A simple measuring method to discriminate between inter- and intragrain current densities in oxide superconductors under given magnetic fields and temperatures is proposed. This is a measurement of the imaginary part of the ac permeability or susceptibility as a function of the ac field amplitude. In this method, the analysis used to derive the penetration depth of the ac field in Campbell’s method or the waveform analysis method is not necessary. This method is useful when the value of the penetration field into the grains and that into the bulk specimen are remarkably different.

  12. AC loss measurements of twisted and untwisted BSCCO multifilamentary tapes

    NASA Astrophysics Data System (ADS)

    Jiang, Zhenan; Amemiya, Naoyuki; Nishioka, Takamasa; Oh, Sang-Soo

    2005-01-01

    AC losses in twisted and untwisted BSCCO multifilamentary superconducting tapes with Ag matrix developed in DAPAS program were measured by an electrical method. Magnetization and transport losses were measured by a pick-up coil and by a voltage taps. Total AC loss during simultaneous application of AC transport current and an AC transverse magnetic field was given by the sum of the magnetization and transport losses measured during this simultaneous application. The magnetization loss without transport current of untwisted and twisted tapes was measured first to evaluate the effect of twisting to decouple filaments. Then, the total AC loss of the twisted tape was measured in transverse magnetic fields with various amplitudes and orientations, while the amplitude of the transport current was fixed. The measured total AC loss in a parallel transverse magnetic field was compared with some theoretical models to study the detailed characteristics of the measured total AC loss of the sample.

  13. Absolute method of measuring magnetic susceptibility

    USGS Publications Warehouse

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  14. Anisotropy of magnetic susceptibility: Measurement schemes

    NASA Astrophysics Data System (ADS)

    Borradaile, Graham John; Stupavsky, Mike

    The precision of AMS determination is enhanced by measuring susceptibility in directions with a uniform orientation distribution that include the four body diagonals. Some standard 10.5 cm³ samples with mean susceptibility < 100µSI possess too few “magnetic” grains for reliable petrofabric interpretation whatever the measurement strategy. We should only interpret their AMS if they pass fabric homogeneity tests.

  15. On the origin of magnetic a.c. susceptibility non-SRT anomalies in intermetallic compounds

    SciTech Connect

    Bartolome, J.; Garcia, L.M.; Lazaro, F.J.; Grincourt, Y.; Fuente, L.G. de la; Francisco, C. de; Munoz, J.M.; Fruchart, D.

    1994-03-01

    The anomaly detected in the magnetic a.c. susceptibility of many intermetallic compounds between 100 and 300 K, and in particular in Nd{sub 2}Fe{sub 14}B at 220 K, has been induced in a controlled manner by thermal annealing. The anomaly has been interpreted in terms of thermal activated processes of defects imposing their dynamical behavior on the domain walls coupled to them, thus solving the controversy on its origin.

  16. An ac susceptibility study in capped Ni/Ni(OH)2 core-shell nanoassemblies: dual peak observations

    NASA Astrophysics Data System (ADS)

    Godsell, Jeffrey F.; Bala, Tanushree; Ryan, Kevin M.; Roy, Saibal

    2011-08-01

    In this study, the ac susceptibility (χ' and χ'') variation with temperature (10-100 K) for oleic acid (OA) capped Ni/Ni(OH)2 core-shell nanoparticle assemblies are reported at frequencies varying from 0.1 to 1000 Hz. Nanoparticle assemblies, with two average particle diameters of ~34 nm and ~14 nm, were synthesized using a wet chemical synthesis approach. Two peaks in the ac susceptibility versus temperature curves are clearly discernable for each of the samples. The first, occurring at ~22 K was attributed to the paramagnetic/antiferromagnetic transition of the Ni(OH)2 present in the shell. The second higher temperature peak was attributed to the superparamagnetic blocking of the pure Ni situated at the core of the nanoparticles. The higher temperature peaks in both the χ' and χ'' curves were observed to increase with increasing frequency. Thus the Néel and the blocking temperatures for such core-shell nanoassemblies were clearly identified from the ac analysis, whereas they were not discernible (superimposed) even from very low dc (FC/ZFC) field measurements. Interparticle interactions within the assemblies were studied through the fitting of phenomenological laws to the experimental datasets. It is observed that even with an OA capping layer, larger Ni/Ni(OH)2 nanoparticles experience a greater degree of sub-capping layer oxidation thus producing lower magnetic interaction strengths.

  17. AC susceptibility analysis on MgB2 bulk and Ti-sheathed wire superconductors

    NASA Astrophysics Data System (ADS)

    Çiçek, Özlem; Yetiş, Hakan; Gencer, Ali

    2014-09-01

    We report a comparative study for bulk MgB2 superconductors and monofilamentary Ti/MgB2 wires as functions of the boron powder purity, average particle size of magnesium, and applied pressure. The structural and magnetic characterizations of the bulk samples were performed by means of XRD and AC susceptibility measurements, respectively. We found that the applied pressure did not cause any significant change on the onset transition temperature Tc,onset and transition width. This is also confirmed by the calculation of the lattice parameters. On the other hand, Tc,onset values were measured as 37.3 K, 38.0 K, and 38.6 K for the samples prepared from the precursor boron powders with purities of 95.2%, ⩾95%, and >98%, respectively. However Mg-particle size (Mg1: AlfaAesar Mg powder, avg. par. size: -325 mesh, purity: 99.8%; Mg2: SigmaAldrich Mg powder, avg. par. size: 20-230 mesh, purity: 98%) did not affect the Tc,onset but increasing the Mg particle size caused a significant broadening at the superconducting transition width for all precursor boron powder purity levels. Magnetization measurements showed that the critical current density of Ti/MgB2 wire prepared from AlfaAesar Mg powder (avg. par. size: -325 mesh) and Aldrich B powder (amorphous, purity ⩾ 95%) is greater than that of prepared by SigmaAldrich Mg powder (avg. par. size: 20-230 mesh) and Pavezyum B powder (amorphous, avg. par. size: 0,3 μm (max), purity > 98%) as 2.6 × 105 A/cm2 and 1.4 × 105 A/cm2 at T = 10 K and μ0H = 0.5 T, respectively. In addition, SigmaAldrich Mg and Pavezyum B wire sample has a lower pinning force, Fp, value at each temperature.

  18. AC susceptibility as a tool to probe the dipolar interaction in magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Landi, Gabriel T.; Arantes, Fabiana R.; Cornejo, Daniel R.; Bakuzis, Andris F.; Andreu, Irene; Natividad, Eva

    2017-01-01

    The dipolar interaction is known to substantially affect the properties of magnetic nanoparticles. This is particularly important when the particles are kept in a fluid suspension or packed within nano-carriers. In addition to its usual long-range nature, in these cases the dipolar interaction may also induce the formation of clusters of particles, thereby strongly modifying their magnetic anisotropies. In this paper we show how AC susceptibility may be used to obtain information regarding the influence of the dipolar interaction in a sample. We develop a model which includes both aspects of the dipolar interaction and may be fitted directly to the susceptibility data. The usual long-range nature of the interaction is implemented using a mean-field approximation, whereas the particle-particle aggregation is modeled using a distribution of anisotropy constants. The model is then applied to two samples studied at different concentrations. One consists of spherical magnetite nanoparticles dispersed in oil and the other of cubic magnetite nanoparticles embedded on polymeric nanospheres. We also introduce a simple technique to address the presence of the dipolar interaction in a given sample, based on the height of the AC susceptibility peaks for different driving frequencies.

  19. Binding of Bacillus thuringiensis Cry1Ac Toxin to Aminopeptidase in Susceptible and Resistant Diamondback Moths (Plutella xylostella)

    PubMed Central

    Luo, K.; Tabashnik, B. E.; Adang, M. J.

    1997-01-01

    Bacillus thuringiensis Cry1Ac toxin bound to a 120-kDa protein isolated from the brush border membranes of both susceptible and resistant larvae of Plutella xylostella, the diamondback moth. The 120-kDa protein was purified by Cry1Ac toxin affinity chromatography. Like Cry1Ac-binding aminopeptidase N (EC 3.4.11.2) from other insects, this protein was eluted from the affinity column with 200 mM N-acetylgalactosamine. The purified protein had aminopeptidase activity and bound Cry1Ac toxin on ligand blots. Purified aminopeptidase was recognized by antibodies to the cross-reacting determinant found on phosphatidylinositol-specific phospholipase C-solubilized proteins. The results show that the presence of Cry1Ac-binding aminopeptidase in the brush border membrane is not sufficient to confer susceptibility to Cry1Ac. Furthermore, the results do not support the hypothesis that resistance to Cry1Ac was caused by lack of a Cry1Ac-binding aminopeptidase. PMID:16535536

  20. Upper critical field and AC-Susceptibility studies on FeTe0.5Se0.5 superconductor

    NASA Astrophysics Data System (ADS)

    Zargar, Rayees A.; Pal, Anand; Hafiz, A. K.; Awana, V. P. S.

    2015-06-01

    In this study we present synthesis and characterization of FeTe0.5Se0.5 sample that has been prepared by solid state reaction route by encapsulation of stoichiometric high purity (5N) ingredients in an evacuated quartz tube at 750 °C. The resultant compound is crystallized in single phase tetragonal structure with space group P4/nmm, having lattice parameters a = 3.792(1) Å and c = 6.0081(3) Å. The studied compound is superconducting at below 13K in both magnetic and transport measurements. Further superconductivity is barely affected by external applied magnetic field, giving rise to upper critical field of above 180 Tesla at 0 K. The sample is studied extensively for AC susceptibility measurements in superconducting state. The AC drive field and frequency are varied from 1-13 Oe and 33-9999 Hz respectively. It is concluded that though the grain boundaries of this superconductor are mainly metallic the minor (undetectable in XRD) foreign phases and the role of porosity cannot be ruled out completely. This is because both frequency and amplitude affects slightly the superconductivity coupling temperature of the grains.

  1. AC Susceptibility of the Dipolar Spin Ice Dy2Ti2O7: Experiments and Monte Carlo Simulations

    NASA Astrophysics Data System (ADS)

    Takatsu, Hiroshi; Goto, Kazuki; Otsuka, Hiromi; Higashinaka, Ryuji; Matsubayashi, Kazuyuki; Uwatoko, Yoshiya; Kadowaki, Hiroaki

    2013-10-01

    Experimental data of the frequency-dependent ac susceptibilityac(ω)] for the dipolar spin ice Dy2Ti2O7 has been analyzed by Monte Carlo simulations on the basis of the single-spin-flip Metropolis algorithm. We have directly evaluated χac(ω) by applying an ac magnetic field. We found that this simulation reasonably reproduces the experimental behavior of χac(ω) in the temperature range from 0.6 to 1.0 K, where dilute magnetic monopoles diffusively move. The conversion factor from simulation time to real time, i.e., the rate of hopping of monopoles to nearest-neighbor sites, strongly depends on temperature.

  2. Fiber - Optic Devices as Temperature Sensors for Temperature Measurements in AC Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Rablau, Corneliu; Lafrance, Joseph; Sala, Anca

    2007-10-01

    We report on the investigation of several fiber-optic devices as potential sensors for temperature measurements in AC magnetic fields. Common temperature sensors, such as thermocouples, thermistors or diodes, will create random and/or systematic errors when placed in a magnetic field. A DC magnetic field is susceptible to create a systematic offset to the measurement, while in an AC magnetic field of variable frequency random errors which cannot be corrected for can also be introduced. Fiber-Bragg-gratings and thin film filters have an inherent temperature dependence. Detrimental for their primary applications, the same dependence allows one to use such devices as temperature sensors. In an AC magnetic field, they present the advantage of being immune to electromagnetic interference. Moreover, for fiber-Bragg-gratings, the shape factor and small mass of the bare-fiber device make it convenient for temperature measurements on small samples. We studied several thin-film filters and fiber-Bragg-gratings and compared their temperature measurement capabilities in AC magnetic fields of 0 to 150 Gauss, 0 to 20 KHz to the results provided by off-the-shelf thermocouples and thermistor-based temperature measurement systems.

  3. Electron Temperature Measurement by Floating Probe Method Using AC Voltage

    NASA Astrophysics Data System (ADS)

    Satoshi, Nodomi; Shuichi, Sato; Mikio, Ohuchi

    2016-11-01

    This study presents a novel floating probe method to measure electron temperatures using a hollow cathode-type discharge tube. The proposed method detects a shift in the floating potential when an AC voltage is applied to a probe through an intermediary blocking capacitor. The shift in the floating potential is described as a function of the electron temperature and the applied AC voltage. The floating probe method is simpler than the Langmuir probe method because it does not require the measurement of volt-ampere characteristics. As the input AC voltage increases, the electron temperature converges. The electron temperature measured using the floating probe method with an applied sinusoidal voltage shows a value close to the first (tail) electron temperature in the range of the floating potential.

  4. NeuAc alpha 2,3gal-glycoconjugate expression determines cell susceptibility to the porcine rubulavirus LPMV.

    PubMed

    Reyes-Leyva, J; Espinosa, B; Hernandez, J; Zenteno, R; Vallejo, V; Hernández-Jáuregui, P; Zenteno, E

    1997-10-01

    Relevance of membrane sialoglycoconjugates as receptors for infection by the porcine rubulavirus has been determined in vitro by sugar and lectin competition assays and by inhibition of glycosylation. Our results show that NeuAc alpha 2,3Gal but not NeuAc alpha 2,6Gal inhibits the virus infectivity of Vero cells, and the virus was effectively blocked with the lectin Maackia amurensis, specific for NeuAc alpha 2,3Gal. Inhibition of the cellular glycosylation with tunicamycin, deoxinojirimycin as well as neuraminidase treatment diminishes the viral capacity to bind and infect this cell line. Dexamethasone, which promotes the activity of sialyl alpha 2,6 glycosyltransferase, also diminishes the cell susceptibility for infection. This is the first report confirming that NeuAc alpha-2,3Gal recognition is determinant in the pathogenesis of the porcine rubulavirus.

  5. Magneto-electric Effect and Dielectric Susceptibility Measurement Technique at Very Low Temperature

    NASA Astrophysics Data System (ADS)

    Xia, J. S.; Yin, L.; Sullivan, N. S.; Zapf, V. S.; Paduan-Filho, A.

    2016-12-01

    We report the design and operation of a new device for measuring the magneto-electric effects, dielectric susceptibility, and electrical resistance of materials at very low temperatures (below 10 mK). The unique feature of the device is the immersion of the sample in liquid 3He which is cooled with a large (25 m2) surface area sintered silver heat exchanger connected to the nuclear stage of a demagnetization refrigerator. In addition to a DC applied magnetic field (up to 16 T), an AC magnetic field is provided by a Helmholtz coil located outside the sample. With this design the magnetic field-dependent electric susceptibilities, and the DC and AC resistance can be measured simultaneously. The details and performance of the device are discussed, and measurements on interesting new materials such as quantum organic magnets are presented.

  6. ac susceptibility studies of magnetic relaxation in nanoparticles of Ni dispersed in silica

    NASA Astrophysics Data System (ADS)

    Singh, V.; Seehra, M. S.; Bonevich, J.

    2009-04-01

    Temperature dependence of ac susceptibilities χ' and χ″ are reported using frequencies fm=0.1, 1, 99, 499, and 997 Hz for nanoparticles of Ni dispersed in silica (Ni/SiO2:15/85) with the mean sizes D =3.8, 11.7, 15, and 21 nm (σ ≃0.2 nm), as determined by transmission electron microscopy. The blocking temperatures TB, as determined by peaks in χ″ versus T data, are fit to the Vogel-Fulcher law based on the following equation: TB=To+Ta/ln(fo/fm). Using the attempt frequency fo=1.82×1010 Hz, Ta (K)=310 (21), 954(17), 1334(14), and 1405(47) are determined for D =3.8, 11.7, 15, and 21 nm, respectively, along with To (representing the interparticle interaction)=0, 0, 6.6(0.7), and 12.5(2.5) K respectively. The magnitudes of Ta=KaV/k yield the anisotropy constant Ka increasing with decreasing D (or volume V) due to contributions from surface anisotropy. The validity of the theoretical result χ″=C∂(χ'T)/∂T with C ≃π/[2 ln(fo/2πfm)] is checked and the calculated values of fo are consistent with experimental value of fo=1.82×1010 Hz.

  7. Ac susceptibility of Ho (Fe,CO)11Ti compounds and their hydrides

    NASA Astrophysics Data System (ADS)

    Tabatabai Yazdi, Sh.; Motevalizadeh, L.

    2015-04-01

    The structural characterization and ac susceptibility behavior of polycrystalline samples of HoFe11-xCoxTiHy (x=1, 2, 4, 6, 7, 9, 11 and y=0, 1) intermetallics are investigated. All compounds crystallize in tetragonal ThMn12-type structure. The replacement of Fe by Co causes the lattice constants to decrease, while hydrogen insertion leads to cell volume expansion. A spin-reorientation (SR) transition from a uniaxial to cone/planar structure is observed for the HoFe11-xCoxTi compounds of higher Co content (x>7). By hydrogenation, SR transition appears in all samples due to relative reinforcement of Ho contribution to anisotropy. TSR values increase by Co-content because of the preferential substitution of Fe by Co atoms and consequently, concentration-dependence of contribution of transition metal sublattice to anisotropy, as well as that of Ho. The concentration-dependence of magnetization direction and hydrogen-induced SR in the studied samples are discussed in the framework of two-magnetic sublattice model by bearing in mind the temperature-dependent competition of their anisotropies and dependence of magnetic anisotropy on crystal field interactions.

  8. Determination of the magnetic ground state in the martensite phase of Ni-Mn-Z (Z = In, Sn and Sb) off-stoichiometric Heusler alloys by nonlinear AC susceptibility.

    PubMed

    Umetsu, R Y; Fujita, A; Ito, W; Kanomata, T; Kainuma, R

    2011-08-17

    DC and AC magnetic measurements were carried out to clarify the difference in the magnetic ground state depending on the kinds of Z element used in the martensite phase in Ni-Mn-Z (Z = In, Sn and Sb) off-stoichiometric Heusler alloys. Magnetic field cooling effects were observed in the DC thermomagnetization curves in the low temperature regions, and a frequency dependence on AC susceptibility was also observed in both real and imaginary parts of the susceptibility. Negative divergence was clearly observed in nonlinear AC susceptibility only for the Ni(50)Mn(40)Sb(10) alloy, suggesting that the magnetic feature of its ground state is the spin-glass state. The magnetic ground state of the martensite phase in these alloys would relate to the magnetic configuration of the Mn atoms in the ferromagnetic austenite phase.

  9. Measurement of the 225Ac half-life.

    PubMed

    Pommé, S; Marouli, M; Suliman, G; Dikmen, H; Van Ammel, R; Jobbágy, V; Dirican, A; Stroh, H; Paepen, J; Bruchertseifer, F; Apostolidis, C; Morgenstern, A

    2012-11-01

    The (225)Ac half-life was determined by measuring the activity of (225)Ac sources as a function of time, using various detection techniques: α-particle counting with a planar silicon detector at a defined small solid angle and in a nearly-2π geometry, 4πα+β counting with a windowless CsI sandwich spectrometer and with a pressurised proportional counter, gamma-ray spectrometry with a HPGe detector and with a NaI(Tl) well detector. Depending on the technique, the decay was followed for 59-141 d, which is about 6-14 times the (225)Ac half-life. The six measurement results were in good mutual agreement and their mean value is T(1/2)((225)Ac)=9.920 (3)d. This half-life value is more precise and better documented than the currently recommended value of 10.0 d, based on two old measurements lacking uncertainty evaluations.

  10. Linear and nonlinear ac susceptibilities in polycrystalline low-bandwidth Pr1-xCa(x)MnO3(x = 0.0 − 0.3) manganite.

    PubMed

    Elovaara, T; Huhtinen, H; Majumdar, S; Paturi, P

    2014-07-02

    The complex linear and nonlinear ac susceptibility have been thoroughly investigated in the low bandwidth manganite compound Pr(1-x)Ca(x)MnO3 (PCMO) for the doping range x = 0.0-0.3 with and without a superimposed background dc field. The dynamical ac response shows substantial differences between the samples. The sample with x = 0.1 is found to have two separate magnetic transition peaks, compared to the single transitions in the samples x = 0.0 and x = 0.2. The nonlinear ac susceptibility measurements were compared between samples, which confirmed that these transition peaks are similar in nature and from the same magnetic origin. Additionally, for sample x = 0.3 a complex transition peak structure with overlapping transition peaks was found. This kind of evolution of the magnetic phases as a function of the Ca concentration is believed to rise from coexisting antiferromagnetic (AFM) and ferromagnetic (FM) orderings, where the Ca concentration controls the amount of FM clusters in the sample. The spin glass characteristics of these complex phase-separated magnetic regimes showed similarities and contradictions with conventional spin glasses, which indicates that this cluster glass behavior arises from the frustration between competing AFM and FM clusters having different magnetic exchange interaction.

  11. Measurements of AC Losses and Current Distribution in Superconducting Cables

    SciTech Connect

    Nguyen, Doan A; Ashworth, Stephen P; Duckworth, Robert C; Carter, Bill; Fleshler, Steven

    2011-01-01

    This paper presents our new experimental facility and techniques to measure ac loss and current distribution between the layers for High Temperature Superconducting (HTS) cables. The facility is powered with a 45 kVA three-phase power supply which can provide three-phase currents up to 5 kA per phase via high current transformers. The system is suitable for measurements at any frequency between 20 and 500 Hz to better understand the ac loss mechanisms in HTS cables. In this paper, we will report techniques and results for ac loss measurements carried out on several HTS cables with and without an HTS shielding layer. For cables without a shielding layer, care must be taken to control the effect of the magnetic fields from return currents on loss measurements. The waveform of the axial magnetic field was also measured by a small pick-up coil placed inside a two-layer cable. The temporal current distribution between the layers can be calculated from the waveform of the axial field.

  12. MR Measurement of Alloy Magnetic Susceptibility: Towards Developing Tissue-Susceptibility Matched Metals

    PubMed Central

    Astary, Garrett W.; Peprah, Marcus K.; Fisher, Charles R.; Stewart, Rachel L.; Carney, Paul R.; Sarntinoranont, Malisa; Meisel, Mark W.; Manuel, Michele V.; Mareci, Thomas H.

    2013-01-01

    Magnetic resonance imaging (MRI) can be used to relate structure to function mapped with high-temporal resolution electrophysiological recordings using metal electrodes. Additionally, MRI may be used to guide the placement of electrodes or conductive cannula in the brain. However, the magnetic susceptibility mismatch between implanted metals and surrounding brain tissue can severely distort MR images and spectra, particularly in high magnetic fields. In this study, we present a modified MR method of characterizing the magnetic susceptibility of materials that can be used to develop biocompatible, metal alloys that match the susceptibility of host tissue in order to eliminate MR distortions proximal to the implant. This method was applied at 4.7 T and 11.1 T to measure the susceptibility of a model solid-solution alloy of Cu and Sn, which is inexpensive but not biocompatible. MR-derived relative susceptibility values of four different compositions of Cu-Sn alloy deviated by less than 3.1% from SQUID magnetometry absolute susceptibility measurements performed up to 7 T. These results demonstrate that the magnetic susceptibility varies linearly with atomic percentage in these solid-solution alloys, but are not simply the weighted average of Cu and Sn magnetic susceptibilities. Therefore susceptibility measurements are necessary when developing susceptibility-matched, solid-solution alloys for the elimination of susceptibility artifacts in MR. This MR method does not require any specialized equipment and is free of geometrical constraints, such as sample shape requirements associated with SQUID magnetometry, so the method can be used at all stages of fabrication to guide the development of a susceptibility matched, biocompatible device. PMID:23727587

  13. MR measurement of alloy magnetic susceptibility: towards developing tissue-susceptibility matched metals.

    PubMed

    Astary, Garrett W; Peprah, Marcus K; Fisher, Charles R; Stewart, Rachel L; Carney, Paul R; Sarntinoranont, Malisa; Meisel, Mark W; Manuel, Michele V; Mareci, Thomas H

    2013-08-01

    Magnetic resonance imaging (MRI) can be used to relate structure to function mapped with high-temporal resolution electrophysiological recordings using metal electrodes. Additionally, MRI may be used to guide the placement of electrodes or conductive cannula in the brain. However, the magnetic susceptibility mismatch between implanted metals and surrounding brain tissue can severely distort MR images and spectra, particularly in high magnetic fields. In this study, we present a modified MR method of characterizing the magnetic susceptibility of materials that can be used to develop biocompatible, metal alloys that match the susceptibility of host tissue in order to eliminate MR distortions proximal to the implant. This method was applied at 4.7T and 11.1T to measure the susceptibility of a model solid-solution alloy of Cu and Sn, which is inexpensive but not biocompatible. MR-derived relative susceptibility values of four different compositions of Cu-Sn alloy deviated by less than 3.1% from SQUID magnetometry absolute susceptibility measurements performed up to 7T. These results demonstrate that the magnetic susceptibility varies linearly with atomic percentage in these solid-solution alloys, but are not simply the weighted average of Cu and Sn magnetic susceptibilities. Therefore susceptibility measurements are necessary when developing susceptibility-matched, solid-solution alloys for the elimination of susceptibility artifacts in MR. This MR method does not require any specialized equipment and is free of geometrical constraints, such as sample shape requirements associated with SQUID magnetometry, so the method can be used at all stages of fabrication to guide the development of a susceptibility matched, biocompatible device.

  14. AC-coupled front-end for biopotential measurements.

    PubMed

    Spinelli, Enrique Mario; Pallàs-Areny, Ramon; Mayosky, Miguel Angel

    2003-03-01

    AC coupling is essential in biopotential measurements. Electrode offset potentials can be several orders of magnitude larger than the amplitudes of the biological signals of interest, thus limiting the admissible gain of a dc-coupled front end to prevent amplifier saturation. A high-gain input stage needs ac input coupling. This can be achieved by series capacitors, but in order to provide a bias path, grounded resistors are usually included, which degrade the common mode rejection ratio (CMRR). This paper proposes a novel balanced input ac-coupling network that provides a bias path without any connection to ground, thus resulting in a high CMRR. The circuit being passive, it does not limit the differential dc input voltage. Furthermore, differential signals are ac coupled, whereas common-mode voltages are dc coupled, thus allowing the closed-loop control of the dc common mode voltage by means of a driven-right-leg circuit. This makes the circuit compatible with common-mode dc shifting strategies intended for single-supply biopotential amplifiers. The proposed circuit allows the implementation of high-gain biopotential amplifiers with a reduced number of parts, thus resulting in low power consumption. An electrocardiogram amplifier built according to the proposed design achieves a CMRR of 123 dB at 50 Hz.

  15. Fast measurement of bacterial susceptibility to antibiotics

    NASA Technical Reports Server (NTRS)

    Chappelle, E. W.; Picciolo, G. L.; Schrock, C. G.

    1977-01-01

    Method, based on photoanalysis of adenosine triphosphate using light-emitting reaction with luciferase-luciferin technique, saves time by eliminating isolation period required by conventional methods. Technique is also used to determine presence of infection as well as susceptibilities to several antibiotics.

  16. Measured losses in superconductor magnets for 60-Hertz ac operation.

    NASA Technical Reports Server (NTRS)

    Hamlet, I. L.; Kilgore, R. A.

    1971-01-01

    Results of an experimental study of electrical losses in superconductor magnets. Preliminary 60-Hz ac loss data are presented for coils constructed of Nb3Sn ribbon, Nb-Ti cable, and multifilament Nb-Ti. Losses have been measured for different size coils up to approximately 20 cm in diameter. Of the conductor types tested, Nb3Sn ribbon has the lowest losses for ac operation. In Nb3Sn-ribbon coils of different sizes, the loss per unit length of conductor is shown to decrease with a decrease in the rate of change of current and to increase, in general, with increase in coil size. An important aspect of the study is the high degree of repeatability of the data.

  17. Materials with low DC magnetic susceptibility for sensitive magnetic measurements

    NASA Astrophysics Data System (ADS)

    Khatiwada, R.; Dennis, L.; Kendrick, R.; Khosravi, M.; Peters, M.; Smith, E.; Snow, W. M.

    2016-02-01

    Materials with very low DC magnetic susceptibility have many scientific applications. To our knowledge however, relatively little research has been conducted with the goal to produce a totally nonmagnetic material. This phrase in our case means after spatially averaging over macroscopic volumes, it possesses an average zero DC magnetic susceptibility. We report measurements of the DC magnetic susceptibility of three different types of nonmagnetic materials at room temperature: (I) solutions of paramagnetic salts and diamagnetic liquids, (II) liquid gallium-indium alloys and (III) pressed powder mixtures of tungsten and bismuth. The lowest measured magnetic susceptibility among these candidate materials is in the order of 10-9 cgs volume susceptibility units, about two orders of magnitude smaller than distilled water. In all cases, the measured concentration dependence of the magnetic susceptibility is consistent with that expected for the weighted sum of the susceptibilities of the separate components within experimental error. These results verify the well-known Wiedemann additivity law for the magnetic susceptibility of inert mixtures of materials and thereby realize the ability to produce materials with small but tunable magnetic susceptibility. For our particular scientific application, we are also looking for materials with the largest possible number of neutrons and protons per unit volume. The gallium-indium alloys fabricated and measured in this work possess to our knowledge the smallest ratio of volume magnetic susceptibility to nucleon number density per unit volume for a room temperature liquid, and the tungsten-bismuth pressed powder mixtures possess to our knowledge the smallest ratio of volume magnetic susceptibility to nucleon number density per unit volume for a room temperature solid. This ratio is a figure of merit for a certain class of precision experiments that search for possible exotic spin-dependent forces of Nature.

  18. Accuracy of MRI-based Magnetic Susceptibility Measurements

    NASA Astrophysics Data System (ADS)

    Russek, Stephen; Erdevig, Hannah; Keenan, Kathryn; Stupic, Karl

    Magnetic Resonance Imaging (MRI) is increasingly used to map tissue susceptibility to identify microbleeds associated with brain injury and pathologic iron deposits associated with neurologic diseases such as Parkinson's and Alzheimer's disease. Field distortions with a resolution of a few parts per billion can be measured using MRI phase maps. The field distortion map can be inverted to obtain a quantitative susceptibility map. To determine the accuracy of MRI-based susceptibility measurements, a set of phantoms with paramagnetic salts and nano-iron gels were fabricated. The shapes and orientations of features were varied. Measured susceptibility of 1.0 mM GdCl3 solution in water as a function of temperature agreed well with the theoretical predictions, assuming Gd+3 is spin 7/2. The MRI susceptibility measurements were compared with SQUID magnetometry. The paramagnetic susceptibility sits on top of the much larger diamagnetic susceptibility of water (-9.04 x 10-6), which leads to errors in the SQUID measurements. To extract out the paramagnetic contribution using standard magnetometry, measurements must be made down to low temperature (2K). MRI-based susceptometry is shown to be as or more accurate than standard magnetometry and susceptometry techniques.

  19. Measurement of AC electrical characteristics of SSC superconducting dipole magnets

    SciTech Connect

    Smedley, K M; Shafer, R E

    1992-01-01

    Experiments were conducted to measure the AC electrical characteristics of SSC superconducting dipole magnets over the frequency range of 0.1 Hz to 10 kHz. A magnet equivalent circuit representing the magnet DC inductance, eddy current losses, coil-to-ground and turn-to-turn capacitance, was synthesized from the experimental data. This magnet equivalent circuit can be used to predict the current ripple distribution along the superconducting magnet string and can provide dynamic information for the design of the collider current regulation loop.

  20. Granularity and vortex dynamics in LaFeAsO0.92F0.08 probed by harmonics of the ac magnetic susceptibility

    NASA Astrophysics Data System (ADS)

    Polichetti, Massimiliano; Adesso, Maria G.; Zola, Danilo; Luo, Jianlin; Chen, G. F.; Li, Zheng; Wang, N. L.; Noce, Canio; Pace, Sandro

    2008-12-01

    Fundamental and higher harmonics of the ac magnetic susceptibility have been measured on LaFeAsO0.92F0.08 samples as a function of the temperature, at various amplitudes and frequencies of the ac magnetic field, with a small superimposed dc field parallel to the ac field. The granularity of the samples has been investigated and the intergrain and intragrain contributions have been clearly individuated looking at both the first and the third harmonics. The vortex dynamics has been also analyzed, and a comparison with the magnetic behavior of both the MgB2 and the cuprate superconductors has been performed. Some vortex dissipative phenomena, i.e., the thermally activated flux flow and the flux creep, have been detected in the presented experimental data, similar to what have been obtained on YBCO. Nevertheless, although the general behavior is similar, several differences have been also evidenced between these different classes of superconductors, mainly in the third harmonics. We infer that different vortex dynamics has to be included into the analysis of the magnetic response in this iron-based material.

  1. AC-magnetic susceptibility of Dy doped ZnO compounds

    NASA Astrophysics Data System (ADS)

    Akyol, Mustafa; Ekicibil, Ahmet; Kiymaç, Kerim

    2015-07-01

    Dy doped ZnO polycrystalline diluted magnetic semiconductor compounds have been prepared by the so called solid state reaction method. We have studied the M-H and AC magnetic properties of the compounds by using a PPMS magnetometer, and explored the phases and crystal structure by using a X-ray powder diffractometer. The XRD spectra of the compounds show that the substitution of Dy3+ for Zn2+ causes almost no change in the hexagonal wurtzite structure of ZnO, and the Dy3+ ions are successfully substituted into the Zn2+ site of the ZnO matrix. The magnetic measurements, M-H and χ-T, for T in the range from 10 to 300 K, show a paramagnetic behavior, including indirect antiferromagnetic couplings between some Dy3+ magnetic moments. Since the Curie-Weiss temperatures, θ, are all negative but decrease in magnitude with increasing Dy concentration. On the other hand, the calculated effective magnetic moments, μeff, per Dy3+ ion slowly increase with increasing Dy concentration, but are all very close to the free ion value of μeff, ~11.0 μB. Therefore, the trends of the magnitudes of θs and μeff s indicate that the samples are not only paramagnetic but also have antiferromagnetic couplings due to the complex nature of the compounds. In addition, the thermal variation of average magnetic moment, Peff(T), per Dy3+ ion have been calculated, and have been found to be gradually increasing with increasing temperature and Dy concentration.

  2. The influence of soil moisture on magnetic susceptibility measurements

    NASA Astrophysics Data System (ADS)

    Maier, G.; Scholger, R.; Schön, J.

    2006-06-01

    An important methodological question for magnetic susceptibility measurements is if a variation of the soil conductivity, as a result of a change in soil moisture, influences the measured susceptibility values. An answer to this question is essential because an accurate magnetic susceptibility mapping requires a grid of comparable magnetic susceptibility values, which indicate the magnetic iron-mineral contents of the soils. Therefore, in the framework of the MAGPROX project (EU-Project EVK2-CT-1999-00019), the study aims at investigating the influence of soil moisture and the possible correlation between magnetic susceptibility and electric conductivity. This approach was realised by model experiments in the laboratory and a field monitoring experiment, which was performed in an analogical manner as the model. For the laboratory experiment, a plastic tub with a water in- and outflow system and installed lines of electrodes was used. The measurements were carried out with layers of different magnetic material within the experimental sand formation under varying water saturation conditions. For the field experiment, which was carried out from July to December 2003, two test sites were selected. The magnetic susceptibility was measured by means of the recently developed vertical soil profile kappa meter SM400 and a commonly used Bartington MS2D probe. The electric resistivity was recorded using a 4-point light system (laboratory) and a ground conductivity meter EM38 (field). The knowledge of the resistivity of the sand formation enabled an estimation of porosity and water saturation in consideration of the Archie equations. The laboratory experiment results showed a very slight variation of measured magnetic susceptibility under different degrees of moisture, indicating mainly the influence from the diamagnetic contribution of the water volume. A measurement error in connection with the measurement method, for example caused by an interfering effect of soil

  3. AC susceptibility study at the inter- and intragranular properties in (Bi,Pb):2223 superconductor

    SciTech Connect

    Pop, A.V.; Ciurchea, D.; Ilonca, G.; Deltour, R.; Harabor, A.

    1997-11-20

    The temperature and amplitude of AC field dependencies of both inter- and intragranular T{sub p} and T{sub g} temperatures of the imaginary peaks of {chi}{double_prime} has been studied for a sintered single phase (Bi,Pb):2223 superconductor. The AC field dependencies for T{sub p} and T{sub g} and the relation between inter- and intragrain force densities were discussed by using Mueller critical-state model. From the {chi}{double_prime} curve, the values of intergrain magnetic critical current density J{sub cJ} was obtained via the application of Beans` critical state model. J{sub cJ}(T) dependence near {Tc} agree with the assumption of SNS intergrain junctions.

  4. Successive superconducting transitions in Ta2S2C studied by electrical resistivity and nonlinear ac magnetic susceptibility

    NASA Astrophysics Data System (ADS)

    Suzuki, Masatsugu; Suzuki, Itsuko S.; Noji, Takashi; Koike, Yoji; Walter, Jürgen

    2007-05-01

    Ta2S2C compound undergoes superconducting transitions at Tcl=3.60±0.02K and Tcu=9.0±0.2K . The nature of successive superconducting transitions has been studied from electrical resistivity and linear and nonlinear ac magnetic susceptibilities. The resistivity ρ at H=0 shows a local maximum near Tcu , a kinklike behavior around Tcl , and reduces to zero at below T0=2.1K . The lnT dependence of ρ is observed at H=50kOe at low temperatures, which is due to a two-dimensional weak-localization effect. Below Tcu , a two-dimensional superconducting phase occurs in each TaC layer. The linear and nonlinear susceptibilities χ1″ , χ3' , χ5' , and χ7' as well as the difference δχ (=χFC-χZFC) between the field-cooled (FC) and zero-field-cooled (ZFC) susceptibilities start to appear below 6.0K , the onset temperature of irreversibility. A drastic growth of the in-plane superconducting coherence length below 6.0K gives rise to a three-dimensional superconducting phase below Tcl through interplanar Josephson couplings between adjacent TaC layers. The oscillatory behavior of χ3″ , χ5″ , and χ7″ below Tcl is related to the nonlinear behavior arising from the thermally activated flux flow.

  5. Redesign of an AC Magnetic Susceptometer for Measurements in Smaller Samples

    NASA Astrophysics Data System (ADS)

    Vargas, Andres; Fukuda, Ryan; Sunny, Smitha; Ho, Pei-Chun

    2013-03-01

    A new AC magnetic susceptometer was created for the purpose of measuring the magnetic properties of smaller samples, such as nanoparticles that are currently being synthesized in our lab. The susceptometer consists of a primary coil, a secondary coil, and a sample holder. The primary coil is the outer component of the susceptometer, which provides a magnetic field when current is applied due to Ampere's Law. Inside of the primary coil lies the secondary coil, which has two oppositely wound solenoids; they are oppositely wound to reduce background signal. The sample holder lies inside of the secondary coil with the sample. All of these go inside of a beryllium copper casing for protection. We tested the susceptometer by looking for the ferromagnetic phase transition of an 11 mg Gd sample. A ~ 100 μ A AC current was applied to the primary coil, which created a magnetic field that polarized the magnetic moments in the sample. This induced a voltage on the secondary coil, which is proportional to the magnetic susceptibility. We measured the temperature dependency of the induced voltage from 10 K to 300 K. The results showed a sharp increase in the induced voltage around 293K, which agrees with the known ferromagnetic transition of Gd. Research at CSU-Fresno is supported by NSF DMR-1104544. Felipe Vargas is also supported by Undergraduate Research Grant and Faculty-Sponsored Student Research Award at CSU Fresno.

  6. Magnetic Susceptibility Measurements for in Situ Characterization of Lunar Soil

    NASA Technical Reports Server (NTRS)

    Oder, R. R.

    1992-01-01

    Magnetic separation is a viable method for concentration of components of lunar soils and rocks for use as feedstocks for manufacture of metals, oxygen, and for recovery of volatiles such as He-3. Work with lunar materials indicates that immature soils are the best candidates for magnetic beneficiation. The magnetic susceptibility at which selected soil components such as anorthite, ilmenite, or metallic iron are separated is not affected by soil maturity, but the recovery of the concentrated components is. Increasing soil maturity lowers recovery. Mature soils contain significant amounts of glass-encased metallic iron. Magnetic susceptibility, which is sensitive to metallic iron content, can be used to measure soil maturity. The relationship between the ratio of magnetic susceptibility and iron oxide and the conventional maturity parameter, I(sub s)/FeO, ferromagnetic resonant intensity divided by iron oxide content is given. The magnetic susceptibilities were determined using apparatus designed for magnetic separation of the lunar soils.

  7. Critical current densities of Sr0.6K0.4Fe2As2 superconductors estimated from AC susceptibilities

    NASA Astrophysics Data System (ADS)

    Setoyama, Subaru; Kinoshita, Junichi; Akune, Tadahiro; Sakamoto, Nobuyoshi; Murakami, Kouji; Yoshida, Nobuyuki; Kiuchi, Masaru; Otabe, Edmund Soji; Matsushita, Teruo; Ge, Jun; Ni, Baorong; Wang, Lei; Qi, Yanpeng; Zhang, Xianping; Gao, Zhaoshun; Ma, Yanwei

    2013-01-01

    AC susceptibilities (real χ‧ and imaginary χ″) of Sr0.6K0.4Fe2As2 (122 type) polycrystalline with Ag addition are analysed by the grained Bean model. A variety of characteristics, double peak in χ″ and shoulder transition in χ‧, appear in the model simulation. Comparing the measured χ‧ and χ″ with the model allows more clear insight on the polycrystalline structure. Estimated critical current densities Jcg and Jcℓ of the grain and the link in the iron-based pnictides show that the addition of 20 wt.% Ag increases Jcℓ 9 times larger. Improvement of intergrain characteristics with Ag addition is clearly indicated.

  8. Absorption and Attenuation Coefficients Using the WET Labs ac-s in the Mid-Atlantic Bight: Field Measurements and Data Analysis

    NASA Technical Reports Server (NTRS)

    Ohi, Nobuaki; Makinen, Carla P.; Mitchell, Richard; Moisan, Tiffany A.

    2008-01-01

    Ocean color algorithms are based on the parameterization of apparent optical properties as a function of inherent optical properties. WET Labs underwater absorption and attenuation meters (ac-9 and ac-s) measure both the spectral beam attenuation [c (lambda)] and absorption coefficient [a (lambda)]. The ac-s reports in a continuous range of 390-750 nm with a band pass of 4 nm, totaling approximately 83 distinct wavelengths, while the ac-9 reports at 9 wavelengths. We performed the ac-s field measurements at nine stations in the Mid-Atlantic Bight from water calibrations to data analysis. Onboard the ship, the ac-s was calibrated daily using Milli Q-water. Corrections for the in situ temperature and salinity effects on optical properties of water were applied. Corrections for incomplete recovery of the scattered light in the ac-s absorption tube were performed. The fine scale of spectral and vertical distributions of c (lambda) and a (lambda) were described from the ac-s. The significant relationships between a (674) and that of spectrophotometric analysis and chlorophyll a concentration of discrete water samples were observed.

  9. EM susceptibility studies and measurements on electro explosive devices

    NASA Astrophysics Data System (ADS)

    Deb, G. K.; Mukherjee, M.

    Electroexplosive devices (EEDs) are susceptible to stray electromagnetic (EM) fields near high-power communications and radar transmitters. Experiments have been carried out to measure the exact susceptibility of EED resistive squibs in pulsed and continuous EM environments, respectively. The susceptibility test procedure consisted of individual measurements of direct current sensitivity (mA); impulse sensitivity; RF impedance measurements; and safety margin calculations. A stray energy monitor was used to evaluate the safe performance of a hybrid weapons system. It is found that the RF sensitivity of the squib was influenced by the transmission characteristics of the transmission line connected to it. RF absorption peaks were observed above the EED sensitivity threshold of 120 MHz. Methods of EMI control are discussed, including: low-pass pin filters; lossy line filters for all dc power line interconnections; and twisting and shielding of the wires.

  10. Effect of Low-Frequency AC Magnetic Susceptibility and Magnetic Properties of CoFeB/MgO/CoFeB Magnetic Tunnel Junctions

    PubMed Central

    Chen, Yuan-Tsung; Lin, Sung-Hao; Sheu, Tzer-Shin

    2014-01-01

    In this investigation, the low-frequency alternate-current (AC) magnetic susceptibilityac) and hysteresis loop of various MgO thickness in CoFeB/MgO/CoFeB magnetic tunneling junction (MTJ) determined coercivity (Hc) and magnetization (Ms) and correlated that with χac maxima. The multilayer films were sputtered onto glass substrates and the thickness of intermediate barrier MgO layer was varied from 6 to 15 Å. An experiment was also performed to examine the variation of the highest χac and maximum phase angle (θmax) at the optimal resonance frequency (fres), at which the spin sensitivity is maximal. The results reveal that χac falls as the frequency increases due to the relationship between magnetization and thickness of the barrier layer. The maximum χac is at 10 Hz that is related to the maximal spin sensitivity and that this corresponds to a MgO layer of 11 Å. This result also suggests that the spin sensitivity is related to both highest χac and maximum phase angle. The corresponding maximum of χac is related to high exchange coupling. High coercivity and saturation magnetization contribute to high exchange-coupling χac strength.

  11. The use of field dependence of AC susceptibility for the interpretation of magnetic mineralogy and magnetic fabrics in the HSDP-2 basalts, Hawaii [rapid communication

    NASA Astrophysics Data System (ADS)

    Vahle, Carsten; Kontny, Agnes

    2005-09-01

    We applied the field dependence parameter χHd (%) = [( k300A/m - k30A/m) / k300A/m] × 100 given by de Wall for the subaerial and submarine basalts drilled by the 3109 m deep HSDP-2 borehole on Hawaii in order to verify the hypothesis that mainly composition controls the field dependence of AC susceptibility in titanomagnetite of natural occurrences. When we used this parameter, our data showed a significant scattering compared to data presented in earlier studies. In addition to composition, the effect of measurement temperature, grain size and anisotropy on the field dependent susceptibility were examined and found to be critical. The impact of grain size is weaker than the other effects. It cannot be totally excluded that the observed effects arise indirectly through an overlap of the other effects for the investigated basalts. The most important factor for the variation of field dependence is the degree of oxidation, causing a modification of the titanomagnetite composition or formation of titanomaghemite, and the mixing of Ti-rich with Ti-poor titanomagnetites, which strongly reduces the χHd parameter. Field dependence is not only related to titanomagnetite composition, especially for intermediate titanomagnetites with TCs between 100 and 300 °C. Temperature dependent susceptibility measurements at different field amplitudes for these intermediate types showed at constant geometry of the k( T) curve great differences in susceptibility, resulting in significant changes of the field dependence parameter over the temperature interval from - 100 to 260 °C. Therefore variations of the ambient measurement temperatures are able to influence the field dependence. The second important effect is the degree of particle shape and alignment, which controls the field dependence in different orientations especially for the intermediate titanomagnetite, which is intensively intergrown with elongated hemoilmenite grains. As a consequence, samples with higher degrees of

  12. Cavitation Susceptibility Measurements of Ocean Lake and Laboratory Waters.

    DTIC Science & Technology

    1986-05-01

    32 *13 - A Typical Acoustic Signal from Single Bubble Bursting............................. 33 14 -Cavitation Event...waters. rhe environmental effect on cavitation was measured by a cavitation susceptibility meter consisting of a venturi, a hydrophone , a pressure...rate is regulated by a motor-speed controller in the shipboard subsystem. The cavitation signals are detected by a wideband high frequency hydrophone

  13. Understanding the Magnetic Susceptibility Measurements by Using an Analytical Scale

    ERIC Educational Resources Information Center

    Cano, M. E.; Cordova-Fraga, T.; Sosa, M.; Bernal-Alvarado, J.; Baffa, O.

    2008-01-01

    A description of the measurement procedure, related theory and experimental data analysis of the magnetic susceptibility of materials is given. A short review of previous papers in the line of this subject is presented. This work covers the whole experimental process, in detail, and presents a pragmatic approach for pedagogical sake. (Contains 2…

  14. The ac-magnetic susceptibility and dielectric response of complex spin ordering processes in Mn₃O₄

    SciTech Connect

    Thota, Subhash E-mail: wilfrid.prellier@ensicaen.fr; Singh, Kiran; Simon, Ch.; Prellier, Wilfrid E-mail: wilfrid.prellier@ensicaen.fr; Nayak, Sanjib; Kumar, Jitendra

    2014-09-14

    We report a meticulous study of the ac-magnetization dynamics (χ{sub ac}(T)), relative dielectric permittivity ε{sub r}(T), and magneto-dielectric (Δε{sub r}/ε{sub r}(H)) response of various complex magnetic transitions that occur below the ferrimagnetic Néel temperature T{sub N} of Mn₃O₄. Besides the known sequence of transitions at T{sub N}~42.75 K, T₁~39 K, and T₂~34 K, the existence of a new anomaly reported recently at 38 K (T*) has been successfully probed by χ{sub ac}(T) and ε{sub r}(T) measurements. The effect of external dc-bias fields (H{sub DC}) and driving frequency (f) on the above mentioned transitions has been investigated in consonance with the ε{sub r}(T) and Δε{sub r}/ε{sub r}(T,H) results. For the first time, we observed a clear hysteresis of about 5.15 K in the zero-field ε{sub r}(T) across the incommensurate-to-commensurate transition T₂~34 K, which provides evidence to the first-order nature of this transition. The Arrott plot (H/M vs. M²}) criterion has been used to distinguish the nature of all the sequential transitions that take place below T{sub N}.

  15. Ac-susceptibility investigations of superspin blocking and freezing in interacting magnetic nanoparticle ensembles

    NASA Astrophysics Data System (ADS)

    Botez, Cristian E.; Morris, Joshua L.

    2016-03-01

    We have investigated the effect of dipolar interactions on the superspin blocking and freezing of 9 nm average size Fe3O4 magnetic nanoparticle ensembles. Our dynamic susceptibility data reveals a two-regime behavior of the blocking temperature, T B, upon diluting a Fe3O4/hexane magnetic fluid. As the nanoparticle volume ratio, Φ, is reduced from an as-prepared reference Φ = 1 to Φ = 1/96, the blocking temperature decreases from 46.1 K to 34.2 K, but higher values reenter upon further diluting the magnetic fluid to Φ = 1/384 (where T B = 42.5 K). We found evidence that cooling below T B within the higher concentration range (Φ > 1/48) leads to the collective freezing of the superspins, whereas individual superspin blocking occurs in the presence of weaker interactions (Φ < 1/96). The unexpected increase of the blocking temperature with the decrease of the inter-particle interactions observed at low nanoparticle concentrations is well described by the Mørup-Tronc model.

  16. Transmission Measurement of the Third-Order Susceptibility of Gold

    NASA Technical Reports Server (NTRS)

    Smith, David D.; Yoon, Youngkwon; Boyd, Robert W.; Crooks, Richard M.; George, Michael

    1999-01-01

    Gold nanoparticle composites are known to display large optical nonlinearities. In order to assess the validity of generalized effective medium theories (EMT's) for describing the linear and nonlinear optical properties of metal nanoparticle composites, knowledge of the linear and nonlinear susceptibilities of the constituent materials is a prerequisite. In this study the inherent nonlinearity of the metal is measured directly (rather than deduced from a suitable EMT) using a very thin gold film. Specifically, we have used the z-scan technique at a wavelength near the transmission window of bulk gold to measure the third-order susceptibility of a continuous thin gold film deposited on a quartz substrate surface-modified with a self-assembled monolayer to promote adhesion and uniformity without affecting the optical properties. We compare our results with predictions which ascribe the nonlinear response to a Fermi-smearing mechanism. Further, we note that the sign of the nonlinear susceptibility is reversed from that of gold nanoparticle composites.

  17. Calorimetric method of ac loss measurement in a rotating magnetic field.

    PubMed

    Ghoshal, P K; Coombs, T A; Campbell, A M

    2010-07-01

    A method is described for calorimetric ac-loss measurements of high-T(c) superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines.

  18. Calorimetric method of ac loss measurement in a rotating magnetic field

    SciTech Connect

    Ghoshal, P. K.; Coombs, T. A.; Campbell, A. M.

    2010-07-15

    A method is described for calorimetric ac-loss measurements of high-T{sub c} superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines.

  19. Calorimetric method of ac loss measurement in a rotating magnetic field

    NASA Astrophysics Data System (ADS)

    Ghoshal, P. K.; Coombs, T. A.; Campbell, A. M.

    2010-07-01

    A method is described for calorimetric ac-loss measurements of high-Tc superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines.

  20. Contribution of the P2X7 1513A/C loss-of-function polymorphism to extrapulmonary tuberculosis susceptibility in Tunisian populations.

    PubMed

    Ben-Selma, Walid; Ben-Kahla, Imen; Boukadida, Jalel; Harizi, Hedi

    2011-10-01

    The P2X7 receptor has been found to be linked to an increased risk for tuberculosis in some populations. In this study, we investigate whether the P2X7 receptor plays a role in increasing susceptibility to tuberculosis in Tunisia. We examined two 1513A/C and -762T/C polymorphisms at the P2X7 receptor in 168 patients with pulmonary TB (pTB), 55 patients with extrapulmonary TB (epTB) and 150 blood donors from Tunisia. Genotyping of 1513A/C and -762T/C polymorphisms was performed in purified genomic DNA using PCR-restriction fragment length polymorphism and allele-specific PCR, respectively. The 1513C, CC and AC loss-of-function allele and genotypes were overrepresented in the epTB group compared with the control group (45% vs. 17%, P=10(-8) ; 24% vs. 4%, P=3 × 10(-7) ; 42% vs. 27%, P=10(-3) , respectively). Additionally, they were associated with 3.83-, 11.86- and 3.15-fold risks of developing this clinical tuberculosis form, respectively. No associations between the -762T/C polymorphism and tuberculosis disease, as well as disease anatomic location were observed. Collectively, our results suggest that the P2X7 1513A/C loss-of-function polymorphism may contribute to susceptibility to epTB in Tunisian populations.

  1. AC loss measurements in HTS coil assemblies with hybrid coil structures

    NASA Astrophysics Data System (ADS)

    Jiang, Zhenan; Long, Nicholas J.; Staines, Mike; Badcock, Rodney A.; Bumby, Chris W.; Buckley, Robert G.; Amemiya, Naoyuki

    2016-09-01

    Both AC loss and wire cost in coil windings are critical factors for high temperature superconductor (HTS) AC machinery applications. We present AC loss measurement results in three HTS coil assemblies at 77 K and 65 K which have a hybrid coil structure comprising one central winding (CW) and two end windings (EWs) wound with ReBCO and BSCCO wires with different self-field I c values at 77 K. All AC loss results in the coil assemblies are hysteretic and the normalized AC losses in the coil assemblies at different temperatures can be scaled with the I c value of the coil assemblies. The normalised results show that AC loss in a coil assembly with BSCCO CW can be reduced by using EWs wound with high I c ReBCO wires, whilst further AC loss reduction can be achieved by replacing the BSCCO CW with ReBCO CW. The results imply that a flexible hybrid coil structure is possible which considers both AC loss and wire cost in coil assemblies.

  2. Magnetic Susceptibility Measurement System for Small and Weak Magnetic Substances

    NASA Astrophysics Data System (ADS)

    Grant, Julius Reynard

    In this study a system is constructed which uses a force method for taking magnetic susceptibility measurements of small (< 100 mg) and weak (< 100x 10-6 emu/g) magnetic substances. The system is constructed with several pieces of readily available hardware. Some of the hardware includes a stable frame structure, a CAHN electrobalance, electromagnet, a thermocouple, a power supply, interfaces, and a personal computer. Each of these components is tested individually as well as together with other devices. Since the electrobalance is extremely sensitive the balance must be placed on a stable frame. The completed system is capable of studying the magnetic properties from room temperature to 77 K of a variety of samples. In addition, a novel method is developed to produce hysteresis loops for especially small and weak magnetic samples. Extensive testing is done to ensure the magnetization results obtained on known samples compare with what has been reported. Some of the samples that have been measured are MnO (TN was 122 K), CdSe (magnetic susceptibility was -0.3 x 10-6 emu/g) with iron attached ligands, FexTeyOz type samples with and without nickel, a YBaCuO superconductor, and cells doped with magnetite nanoparticles. The results are compared to measurements made with SQUID magnetometers.

  3. Comparison of optomagnetic and AC susceptibility readouts in a magnetic nanoparticle agglutination assay for detection of C-reactive protein.

    PubMed

    Fock, Jeppe; Parmvi, Mattias; Strömberg, Mattias; Svedlindh, Peter; Donolato, Marco; Hansen, Mikkel Fougt

    2017-02-15

    There is an increasing need to develop biosensor methods that are highly sensitive and that can be combined with low-cost consumables. The use of magnetic nanoparticles (MNPs) is attractive because their detection is compatible with low-cost disposables and because application of a magnetic field can be used to accelerate assay kinetics. We present the first study and comparison of the performance of magnetic susceptibility measurements and a newly proposed optomagnetic method. For the comparison we use the C-reactive protein (CRP) induced agglutination of identical samples of 100nm MNPs conjugated with CRP antibodies. Both methods detect agglutination as a shift to lower frequencies in measurements of the dynamics in response to an applied oscillating magnetic field. The magnetic susceptibility method probes the magnetic response whereas the optomagnetic technique probes the modulation of laser light transmitted through the sample. The two techniques provided highly correlated results upon agglutination when they measure the decrease of the signal from the individual MNPs (turn-off detection strategy), whereas the techniques provided different results, strongly depending on the read-out frequency, when detecting the signal due to MNP agglomerates (turn-on detection strategy). These observations are considered to be caused by differences in the volume-dependence of the magnetic and optical signals from agglomerates. The highest signal from agglomerates was found in the optomagnetic signal at low frequencies.

  4. Neutron diffraction and ac susceptibility studies of the solid solutions UMM'X 2 (M, M' = Co, Ni, Cu; X = Si, Ge)

    NASA Astrophysics Data System (ADS)

    Kuznietz, Moshe; André, Gilles; Bourée, Françoise; Pinto, Haim; Ettedgui, Hanania; Melamud, Mordechai

    1994-11-01

    Polycrystalline samples of the intermediate solid solutions of the UM 2X 2 compounds (M, M' = Co, Ni, Cu; X = Si, Ge), namely UMM'X 2, have been prepared and studied by ac susceptibility and neutron diffraction measurements. They crystallize in the body-centered tetragonal ThCr 2Si 2-type structure (space group I4/mmm) and order magnetically, with the exception of UCoNiGe 2, which crystallizes in the primitive tetragonal CaBe 2Ge 2-type structure (space group P4/nmm) and does not order magnetically. UCoNiSi 2, UNiCuSi 2, and UNiCuGe 2 order antiferromagnetically below TN = (115±5), (150±2) and (140±5) K, respectively, with the AF-I structure of alternate (+-+-) ferromagnetic uranium basal planes and a wavevector k = (0, 0, 1). UCoCuSi 2 and UCoCuGe 2 order ferromagnetically below TC=(107±5) and (114±5) K and undergo transition to the AF-I structure below To=(95±5) and (94±5) K, respectively. The uranium ordered moments are along the tetragonal axis. The magnetic properties of the UMM'X 2 solid solutions are discussed and compared with those of the UM 2X 2 compounds.

  5. ac susceptibility investigation of vortex dynamics in nearly optimally doped RFeAsO1-xFx superconductors (R = La, Ce, Sm)

    NASA Astrophysics Data System (ADS)

    Prando, G.; Carretta, P.; De Renzi, R.; Sanna, S.; Grafe, H.-J.; Wurmehl, S.; Büchner, B.

    2012-04-01

    Ac susceptibility and static magnetization measurements were performed in the nearly optimally doped LaFeAsO0.9F0.1 and CeFeAsO0.92F0.08 superconductors, complementing earlier results on SmFeAsO0.8F0.2 [Phys. Rev. BPRBMDO1098-012110.1103/PhysRevB.83.174514 83, 174514 (2011)]. The magnetic field-temperature phase diagram of the mixed superconducting state is drawn for the three materials, displaying a sizable reduction of the liquid phase upon increasing Tc in the range of applied fields (H⩽5 T). This result indicates that SmFeAsO0.8F0.2 is the most interesting compound among the investigated ones in view of possible applications. The field-dependence of the intragrain depinning energy U0 exhibits a common trend for all the samples with a typical crossover field value (2500 Oe ≲Hcr≲5000 Oe) separating regions where single and collective depinning processes are at work.

  6. Magnetic Susceptibility Measurements as a Proxy for Hydrocarbon Biodegradation

    NASA Astrophysics Data System (ADS)

    Mewafy, F.; Atekwana, E. A.; Slater, L. D.; Werkema, D.; Revil, A.; Ntarlagiannis, D.; Skold, M.

    2011-12-01

    Magnetic susceptibility (MS) measurements have been commonly used in paleoclimate studies, as a proxy for environmental pollution such as heavy metal contamination, and for delineating zones of oil seeps related to hydrocarbon exploration. Few studies have assessed the use of MS measurements for mapping zones of oil pollution. In this study, we investigated the variation in magnetic susceptibility across a hydrocarbon contaminated site undergoing biodegradation. Our objective was to investigate if MS measurements could be used as a proxy indicator of intrinsic bioremediation linked to the activity of iron reducing bacteria. An improved understanding of the mechanisms generating geophysical signatures associated with microbial enzymatic activity could permit the development of geophysical imaging technologies for long-term, minimally invasive and sustainable monitoring of natural biodegradation at oil spill sites. We used a Bartington MS probe to measure MS data along fifteen boreholes within contaminated (both free phase and dissolved phase hydrocarbon plumes) and clean areas. Our results show the following: (1) an enhanced zone of MS straddling the water table at the contaminated locations, not observed at the clean locations; (2) MS values within the free product plume are higher compared to values within the dissolved product plume; (3) the MS values within the vadoze zone above the free product plume are higher compared to values within the dissolved product plume; 4) the zone of high MS is thicker within the free product plume compared to the dissolved product plume. We suggest that the zone of enhanced MS results from the precipitation of magnetite related to the oxidation of the hydrocarbons coupled to iron reduction. Our data documents a strong correlation between MS and hydrocarbon concentration. We conclude that recognition of these zones of enhanced magnetite formation allows for the application of MS measurements as a: (1) low cost, rapid monitoring

  7. High Susceptibility to Cry1Ac and Low Resistance Allele Frequency Reduce the Risk of Resistance of Helicoverpa armigera to Bt Soybean in Brazil

    PubMed Central

    Bacalhau, Fabiana B.; Amado, Douglas; Carvalho, Renato A.; Martinelli, Samuel; Head, Graham P.; Omoto, Celso

    2016-01-01

    The Old World bollworm, Helicoverpa armigera (Hübner), was recently introduced into Brazil, where it has caused extensive damage to cotton and soybean crops. MON 87701 × MON 89788 soybean, which expresses the Bt protein Cry1Ac, was recently deployed in Brazil, providing high levels of control against H. armigera. To assess the risk of resistance to the Cry1Ac protein expressed by MON 87701 × MON 89788 soybean in Brazil, we conducted studies to evaluate the baseline susceptibility of H. armigera to Cry1Ac, in planta efficacy including the assessment of the high-dose criterion, and the initial resistance allele frequency based on an F2 screen. The mean Cry1Ac lethal concentration (LC50) ranged from 0.11 to 1.82 μg·mL−1 of diet among all H. armigera field populations collected from crop seasons 2013/14 to 2014/15, which indicated about 16.5-fold variation. MON 87701 × MON 89788 soybean exhibited a high level of efficacy against H. armigera and most likely met the high dose criterion against this target species in leaf tissue dilution bioassays up to 50 times. A total of 212 F2 family lines of H. armigera were established from field collections sampled from seven locations across Brazil and were screened for the presence of MON 87701 × MON 89788 soybean resistance alleles. None of the 212 families survived on MON 87701 × MON 89788 soybean leaf tissue (estimated allele frequency = 0.0011). The responses of H. armigera to Cry1Ac protein, high susceptibility to MON 87701 × MON 89788 soybean, and low frequency of resistance alleles across the main soybean-producing regions support the assumptions of a high-dose/refuge strategy. However, maintenance of reasonable compliance with the refuge recommendation will be essential to delay the evolution of resistance in H. armigera to MON 87701 × MON 89788 soybean in Brazil. PMID:27532632

  8. High Susceptibility to Cry1Ac and Low Resistance Allele Frequency Reduce the Risk of Resistance of Helicoverpa armigers to Bt Soybean in Brazil.

    PubMed

    Dourado, Patrick M; Bacalhau, Fabiana B; Amado, Douglas; Carvalho, Renato A; Martinelli, Samuel; Head, Graham P; Omoto, Celso

    2016-01-01

    The Old World bollworm, Helicoverpa armigera (Hübner), was recently introduced into Brazil, where it has caused extensive damage to cotton and soybean crops. MON 87701 × MON 89788 soybean, which expresses the Bt protein Cry1Ac, was recently deployed in Brazil, providing high levels of control against H. armigera. To assess the risk of resistance to the Cry1Ac protein expressed by MON 87701 × MON 89788 soybean in Brazil, we conducted studies to evaluate the baseline susceptibility of H. armigera to Cry1Ac, in planta efficacy including the assessment of the high-dose criterion, and the initial resistance allele frequency based on an F2 screen. The mean Cry1Ac lethal concentration (LC50) ranged from 0.11 to 1.82 μg·mL-1 of diet among all H. armigera field populations collected from crop seasons 2013/14 to 2014/15, which indicated about 16.5-fold variation. MON 87701 × MON 89788 soybean exhibited a high level of efficacy against H. armigera and most likely met the high dose criterion against this target species in leaf tissue dilution bioassays up to 50 times. A total of 212 F2 family lines of H. armigera were established from field collections sampled from seven locations across Brazil and were screened for the presence of MON 87701 × MON 89788 soybean resistance alleles. None of the 212 families survived on MON 87701 × MON 89788 soybean leaf tissue (estimated allele frequency = 0.0011). The responses of H. armigera to Cry1Ac protein, high susceptibility to MON 87701 × MON 89788 soybean, and low frequency of resistance alleles across the main soybean-producing regions support the assumptions of a high-dose/refuge strategy. However, maintenance of reasonable compliance with the refuge recommendation will be essential to delay the evolution of resistance in H. armigera to MON 87701 × MON 89788 soybean in Brazil.

  9. Specific heat, resistivity, and AC susceptibility of the cubic PrX 2 compounds (X = Pt, Ru, Ir, Rh)

    NASA Astrophysics Data System (ADS)

    Greidanus, F. J. A. M.; Nieuwenhuys, G. J.; de Jongh, L. J.; Huiskamp, W. J.; Capel, H. W.; Buschow, K. H. J.

    1983-04-01

    Specific-heat, differential-susceptibility and electrical-resistivity measurements on PrX 2 (X = Ir, Pt, Rh, Ru) compounds reveal phase transitions at Tc = 11.2±0.5 K, 7.7±0.5 K, 7.9±0.5 Kand 33.9±0.5 K for X = Ir, Pt, Rh, and Ru, respective ly. From earlier neutron inelastic scattering experiments, the crystalline electric field levels of these compounds have been determined. The specific-heat results are compared with the results of a mean-field calculation, assuming bilinear exchange interactions. The presence of broad secondary maxima in the temperature dependence of the specific heat of PrRh 2, PrRu 2 and especially PrIr 2 can qualitatively be explained by the presence of biquadratic (quadrupolar) interactions. The behaviour of the susceptibility is in agreement with ferromagnetic ordering. The electrical resistivity drops markedly below Tc, and the dϱ/d T versus T curve is similar to that of the specific heat.

  10. Linear optics measurements and corrections using an AC dipole in RHIC

    SciTech Connect

    Wang, G.; Bai, M.; Yang, L.

    2010-05-23

    We report recent experimental results on linear optics measurements and corrections using ac dipole. In RHIC 2009 run, the concept of the SVD correction algorithm is tested at injection energy for both identifying the artificial gradient errors and correcting it using the trim quadrupoles. The measured phase beatings were reduced by 30% and 40% respectively for two dedicated experiments. In RHIC 2010 run, ac dipole is used to measure {beta}* and chromatic {beta} function. For the 0.65m {beta}* lattice, we observed a factor of 3 discrepancy between model and measured chromatic {beta} function in the yellow ring.

  11. The Wechsler ACS Social Perception Subtest: A Preliminary Comparison with Other Measures of Social Cognition

    ERIC Educational Resources Information Center

    Kandalaft, Michelle R.; Didehbani, Nyaz; Cullum, C. Munro; Krawczyk, Daniel C.; Allen, Tandra T.; Tamminga, Carol A.; Chapman, Sandra B.

    2012-01-01

    Relative to other cognitive areas, there are few clinical measures currently available to assess social perception. A new standardized measure, the Wechsler Advanced Clinical Solutions (ACS) Social Perception subtest, addresses some limitations of existing measures; however, little is known about this new test. The first goal of this investigation…

  12. Human/Nonhuman Primate AC-PC Ratio - Considerations for Translational Brain Measurements

    PubMed Central

    Fiandaca, Massimo S.; Salegio, Ernesto Aguilar; Yin, Dali; Richardson, R. Mark; Valles, Francisco E.; Larson, Paul S.; Starr, Philip A.; Lonser, Russell R.; Bankiewicz, Krystof S.

    2011-01-01

    This comparative magnetic resonance imaging (MRI) analysis evaluated the ratio of AC-PC (anterior commissure to posterior commissure) distance measures in selected groups of humans and nonhuman primates (NHPs). An understanding of the basis of this ratio between primate species may allow more accurate translation of NHP stereotactic targeting measurements to upcoming human trials. MRI datasets of adult humans [n=21], and juvenile and adult NHPs (Macaca fascicularis [n=40], and Macaca mulatta [n=32]), were evaluated in a mid-sagittal plane to obtain the AC-PC distance measure for each examined subject. Two trained evaluators, blinded to each other’s results, carried out three separate measurements of the AC-PC length for each subject. Each observer carried out measurements of the entire dataset [n=93] before repeating the measurements two additional times. Previous dataset measures were not available for review at the time of subsequent measures. Inter- and intra-observer variabilities were not statistically significant. Minimal intraspecies variation was found in the AC-PC measurement of our human and NHP groups. We found significant interspecies differences, however, more between humans and NHPs, and less between the NHP groups. Regression analysis confirms the strong linear relationship of AC-PC distance based primarily on species in our study groups. Human/NHP AC-PC ratios varied between 2.1 to 2.3 based on the compared NHP species groups. We conclude that the scale differences in brain measurements between NHPs and humans described in this study allows improved translation of stereotactic targeting coordinates in future human clinical trials, which may lead to improved efficacy and safety. PMID:21185868

  13. Measurements of AC Loss In Second-Generation HTS Tapes in a DC Magnetic Field

    NASA Astrophysics Data System (ADS)

    Osofsky, M. S.; Soulen, R. J.; Gubser, D. U.; Datta, T.

    2008-03-01

    The successful application of superconductivity to motors and other power system components depends on the characterization and subsequent minimization of the ac loss in the superconductor used for fabrication of the component. The superconductive component, excited by an ac power source, may be exposed to large dc magnetic fields and/or ac fields. To further complicate the situation, the transport properties of the tapes are strongly dependent on the angle between the applied field and the YBCO c-axis (normal to the tape surface). We report on measurements of the transport ac loss of a YBaCuO tape at 65 K, at several frequencies, in applied dc fields of 1-3 T with the field parallel and perpendicular to the tape normal.

  14. Low temperature magnetic ground state in bulk Co0.3Zn0.7Fe2O4 spinel ferrite system: Neutron diffraction, magnetization and ac-susceptibility studies

    NASA Astrophysics Data System (ADS)

    Parmar, Harshida; Acharya, Prashant; Upadhyay, R. V.; Siruguri, V.; Rayaprol, Sudhindra

    2013-01-01

    The system under study is a bulk Co0.3Zn0.7Fe2O4 ferrite, synthesized by wet chemical route technique and having magnetic in-homogeneity at the microscopic scale, due to the concentration of magnetic ion at a tetrahedral site below the site percolation threshold for the ferrimagnetic ordering. To unravel the magnetic ground state of this system, low temperature neutron diffraction, magnetization and ac-susceptibility measurements were carried out. In the temperature-dependent neutron diffraction analysis, a diffused scattering signal appears at the low Q region below (1 1 1) magnetic Bragg peak at all temperature, indicating the presence of a finite magnetic cluster with infinite magnetic network. The diffused scattering signal intensity decreases with increases in magnetic field at T=10 K. The ac-susceptibility measurement exhibits three peak behavior in χ' and χ″ indicating the presence of finite magnetic clusters and cluster-cluster interaction in the system. The absence of magnetic (2 0 0) peak in neutron diffraction at 2 K and bifurcation of zero field and field cooled magnetization indicate the phase transition from uniaxial random ferromagnetic (URF) phase to semi spin glass or canted random ferromagnetic (CRF) phase in the system with temperature.

  15. AC Inductive Measurement of Intergrain and Intragrain Currents in High-Tc Oxide Superconductors

    NASA Astrophysics Data System (ADS)

    Ni, Baorong; Munakata, Toshiyuki; Matsushita, Teruo; Iwakuma, Masataka; Funaki, Kazuo; Takeo, Masakatsu; Yamafuji, Kaoru

    1988-09-01

    Bulk intergrain current and closed intragrain current in sintered Y-Ba-Cu-O superconductors were measured at 77 K by using an ac inductive method. These currents can be separated because of the large difference in penetrating rates of the magnetic flux into specimens with respect to the ac field amplitude. The obtained intergrain current density agreed approximately with critical current density measured resistively. The closed intragrain current density amounted to 4.3× 108 A/m2 at B{=}0.5 T and decreased gradually with increasing magnetic field. The present results show that the ac inductive measurement is one of the available nondestructive methods to characterize sintered oxide specimens.

  16. Measuring the topological susceptibility in a fixed sector

    NASA Astrophysics Data System (ADS)

    Bautista, Irais; Bietenholz, Wolfgang; Dromard, Arthur; Gerber, Urs; Gonglach, Lukas; Hofmann, Christoph P.; Mejía-Díaz, Héctor; Wagner, Marc

    2015-12-01

    For field theories with a topological charge Q , it is often of interest to measure the topological susceptibility χt=(⟨Q2⟩-⟨Q ⟩2)/V . If we manage to perform a Monte Carlo simulation where Q changes frequently, χt can be evaluated directly. However, for local update algorithms and fine lattices, the autocorrelation time with respect to Q tends to be extremely long, which invalidates the direct approach. Nevertheless, the measurement of χt is still feasible, even when the entire Markov chain is topologically frozen. We test a method for this purpose, based on the correlation of the topological charge density, as suggested by Aoki, Fukaya, Hashimoto and Onogi. Our studies in nonlinear σ -models and in two-dimensional Abelian gauge theory yield accurate results for χt, which confirm that the method is applicable. We also obtain promising results in four-dimensional SU(2) Yang-Mills theory, which suggest the applicability of this method in QCD.

  17. Development of Low-Frequency AC Voltage Measurement System Using Single-Junction Thermal Converter

    NASA Astrophysics Data System (ADS)

    Amagai, Yasutaka; Nakamura, Yasuhiro

    Accurate measurement of low-frequency AC voltage using a digital multimeter at frequencies of 4-200Hz is a challenge in the mechanical engineering industry. At the National Metrology Institute of Japan, we developed a low-frequency AC voltage measurement system for calibrating digital multimeters operating at frequencies down to 1 Hz. The system uses a single-junction thermal converter and employs a theoretical model and a three-parameter sine wave fitting algorithm based on the least-square (LS) method. We calibrated the AC voltage down to 1Hz using our measurement system and reduced the measurement time compared with that using thin-film thermal converters. Our measurement results are verified by comparison with those of a digital sampling method using a high-resolution analog-to-digital converter; our data are in agreement to within a few parts in 105. Our proposed method enables us to measure AC voltage with an uncertainty of 25 μV/V (k = 1) at frequencies down to 4 Hz and a voltage of 10 V.

  18. Measuring antimicrobial susceptibility of Pseudomonas aeruginosa using Poloxamer 407 gel.

    PubMed

    Yamada, Hiroyuki; Koike, Naohito; Ehara, Tomoko; Matsumoto, Tetsuya

    2011-04-01

    Pseudomonas aeruginosa is a Gram-negative bacterium that causes various opportunistic infections. Chronic and intractable infections with P. aeruginosa are closely related to the high levels of resistance displayed by this organism to antimicrobial agents and its ability to form biofilms. Although the standard method for examining antimicrobial resistance involves susceptibility testing using Mueller-Hinton agar or broth, this method does not take into account the influence of biofilm formation on antimicrobial susceptibility. Poloxamer 407 is a hydrophilic, nonionic surfactant of the more general class of copolymers that can be used to culture bacteria with similar properties as cells in a biofilm environment. Therefore, the aim of this study was to compare the antimicrobial susceptibility of bacteria cultured in Poloxamer 407 gel to those grown on Mueller-Hinton agar using the Kirby-Bauer disk diffusion method with 24 strains of P. aeruginosa. Antimicrobial sensibility differed between the two mediums, with >60% of the strains displaying increased resistance to β-lactams when cultured on Poloxamer 407 gel. In addition, scanning electron microscopy revealed that typical biofilm formation and extracellular polymeric substance production was only observed with bacteria grown on Poloxamer 407 gel. Therefore, antimicrobial susceptibility test using Poloxamer 407 gel may provide more accurate information and allow the selection of suitable antimicrobial agents for treating patients infected with biofilm-forming pathogens.

  19. Hypnotic Susceptibility and Personality as Measured by the MMPI-2.

    ERIC Educational Resources Information Center

    Parker, Wayne D.

    This study evaluated personality variables that underlie hypnotic susceptibility. It was correlational, did not require ongoing contact with participants, and included a validation study as an integral component. The subjects were 359 college students (250 in the original sample and 109 in the cross validation study) taking undergraduate courses…

  20. Effective method to measure back emfs and their harmonics of permanent magnet ac motors

    NASA Astrophysics Data System (ADS)

    Jiang, Q.; Bi, C.; Lin, S.

    2006-04-01

    As the HDD spindle motors become smaller and smaller, the back electromotive forces (emfs) measurement faces the new challenges due to their low inertias and small sizes. This article proposes a novel method to measure the back emfs and their harmonic components of PM ac motors only through a freewheeling procedure. To eliminate the influence of the freewheeling deceleration, the phase flux linkages are employed to obtain the back emf amplitudes and phases of the fundamental and harmonic components by using finite Fourier series analysis. The proposed method makes the freewheeling measurement of the back emfs and their harmonics accurate and fast. It is especially useful for the low inertia PM ac motors, such as spindle motors for small form factor HDDs.

  1. The 3'UTR 1188A/C polymorphism of IL-12p40 is not associated with susceptibility for developing plaque psoriasis in Mestizo population from western Mexico.

    PubMed

    Sandoval-Talamantes, Ana Karen; Brito-Luna, Myrian Johanna; Fafutis-Morris, Mary; Villanueva-Quintero, Delfina Guadalupe; Graciano-Machuca, Omar; Ramírez-Dueñas, María Guadalupe; Alvarado-Navarro, Anabell

    2015-02-01

    Psoriasis is a chronic autoimmune inflammatory disease that affects the skin and the joints. Psoriasis is characterized by the keratinocyte proliferation, which is induced by cytokines Th1 and Th17. Patients with plaque psoriasis present a chronic inflammatory response with high levels of interleukin (IL)-12 and IL-23. Various single-nucleotide polymorphisms (SNP) have been identified in the IL12B gene, such as SNP 3' UTR 1188 A/C (SNP rs3212227), which has been associated with susceptibility to developing plaque psoriasis and with the production of IL-12 and IL-23 in individuals of different ethnic groups. In this study, we determined whether there is an association of SNP rs3212227 with the susceptibility of developing plaque psoriasis and with serum levels of IL-12 and IL-23 in Mestizo population in western Mexico. We included 112 patients with psoriasis and 112 clinical healthy individuals in the study. The frequencies of genotypes A/A, A/C, and C/C in patients with plaque psoriasis were 41, 53, and 6%, respectively, while in the control group, these were 37, 53, and 10%, respectively, without finding statistically significant differences between both groups (p>0.05). Although IL-12 and IL-23 serum levels were higher in patients than in controls, we found no significant differences. The group of patients with genotype CC presented the highest levels of IL-23 (p<0.05). These data suggest that the SNP rs3212227 phenotype is not associated with the risk of developing plaque psoriasis or with IL-12 and IL-23 levels in Mestizo population in western Mexico.

  2. Measurement of AC Losses in a Racetrack Superconducting Coil Made from YBCO Coated Conductor

    NASA Astrophysics Data System (ADS)

    Seiler, Eugen; Abrahamsen, Asger B.; Kováč, Ján; Wichmann, Mike; Træholt, Chresten

    We present the results of transport measurements of AC losses in a racetrack shaped superconducting coil made from coated conductor tape. The outer dimensions of the coil are approximately 24 cm × 12 cm and it has 57 turns. The coil is impregnated with epoxy resin and fiberglass tape is used to insulate the individual turns and to improve the mechanical properties of the epoxy when exposed to thermal cycling. The coil is manufactured as a part of the field winding of a small synchronous generator; therefore stainless steel frames are installed on the inner and outer side of the winding to reinforce it. The AC loss is measured versus the transport current Ia with the coil immersed in liquid nitrogen. Measurements at frequencies 21 Hz, 36 Hz and 72 Hz are compared. The AC losses follow Ia2 dependence at low current amplitudes and Ia3 at high amplitudes. After cutting the inner steel frame the low amplitude losses are decreased, their frequency dependence is reduced but their dependence on the current remains unchanged.

  3. Ac-loss measurement of a DyBCO-Roebel assembled coated conductor cable (RACC)

    NASA Astrophysics Data System (ADS)

    Schuller, S.; Goldacker, W.; Kling, A.; Krempasky, L.; Schmidt, C.

    2007-10-01

    Low ac-loss HTS cables for transport currents well above 1 kA are required for application in transformers and generators and are taken into consideration for future generations of fusion reactor coils. Coated conductors (CC) are suitable candidates for high field application at an operation temperature around 50-77 K, which is a crucial precondition for economical cooling costs. We prepared a short length of a Roebel bar cable made of industrial DyBCO coated conductor (Theva Company, Germany). Meander shaped tapes of 4 mm width with a twist pitch of 122 mm were cut from 10 mm wide CC tapes using a specially designed tool. Eleven of these strands were assembled to a cable. The electrical and mechanical connection of the tapes was achieved using a silver powder filled conductive epoxy resin. Ac-losses of a short sample in an external ac field were measured as a function of frequency and field amplitude in transverse and parallel field orientations. In addition, the coupling current time constant of the sample was directly measured.

  4. Direct Detection of Pure ac Spin Current by X-Ray Pump-Probe Measurements

    NASA Astrophysics Data System (ADS)

    Li, J.; Shelford, L. R.; Shafer, P.; Tan, A.; Deng, J. X.; Keatley, P. S.; Hwang, C.; Arenholz, E.; van der Laan, G.; Hicken, R. J.; Qiu, Z. Q.

    2016-08-01

    Despite recent progress in spin-current research, the detection of spin current has mostly remained indirect. By synchronizing a microwave waveform with synchrotron x-ray pulses, we use the ferromagnetic resonance of the Py (Ni81Fe19 ) layer in a Py /Cu /Cu75Mn25/Cu /Co multilayer to pump a pure ac spin current into the Cu75Mn25 and Co layers, and then directly probe the spin current within the Cu75Mn25 layer and the spin dynamics of the Co layer by x-ray magnetic circular dichroism. This element-resolved pump-probe measurement unambiguously identifies the ac spin current in the Cu75Mn25 layer.

  5. Broadband Interferometer for Measuring Transmitted Wavefronts of Optical Bandpass Filters for HST (ACS)

    NASA Technical Reports Server (NTRS)

    Boucarut, R. A.; Leviton, D. B.

    1998-01-01

    The transmitted wavefronts of optical filters for the Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS) are characterized using the Wildly and Openly Modified Broadband Achromatic Twyman Green (WOMBAT) Interferometer developed in the NASA/GSFC Optics Branch's Diffraction Grating Evaluation Facility (DGEF). Because only four of thirty-three of ACS's optical bandpass filters transmit the 633 nm light of most commercial interferometers, a broadband interferometer is required to verify specified transmitted wavefront of ACS filters. WOMBAT's design is a hybrid of the BAT interferometer developed by JPL used for HST Wide Field and Planetary Camera 2 (WFPC-2) filters and a WYKO 400 phase shifting interferometer. It includes a broadband light source, monochromator, off-axis, parabolic collimating and camera mirrors, an aluminum-coated fused silica beam splitter, flat retroreflecting mirrors for the test and reference arms, and a LTV-sensitive CCD camera. An outboarded, piezo-electric phase shifter holds the flat mirror in the interferometer's reference arm. The interferometer is calibrated through interaction between the WYKO system's software and WONMAT hardware for the test wavelength of light entering the beam splitter. Phase-shifted interferograms of the filter mounted in the test arm are analyzed using WYKO's Vision' software. Filters as large as 90 mm in diameter have been measured over a wavelength range from 200 to 1100 nm with a sensitivity of lambda/200 rms at lambda = 633 nm. Results of transmitted wavefront measurements are shown for ACS fixed band pass and spatially-variable bandpass filters for a variety of wavelengths.

  6. Recent Advances in AC-DC Transfer Measurements Using Thin-Film Thermal Converters

    SciTech Connect

    WUNSCH,THOMAS F.; KINARD,JOSEPH R.; MANGINELL,RONALD P.; LIPE,THOMAS E.; SOLOMON JR.,OTIS M.; JUNGLING,KENNETH C.

    2000-12-08

    New standards for ac current and voltage measurements, thin-film multifunction thermal converters (MJTCS), have been fabricated using thin-film and micro-electro-mechanical systems (MEMS) technology. Improved sensitivity and accuracy over single-junction thermoelements and targeted performance will allow new measurement approaches in traditionally troublesome areas such as the low frequency and high current regimes. A review is presented of new microfabrication techniques and packaging methods that have resulted from a collaborative effort at Sandia National Laboratories and the National Institute of Standards and Technology (MHZ).

  7. Critical behavior of AC antiferromagnetic and ferromagnetic susceptibilities of a spin-1/2 > metamagnetic Ising system

    NASA Astrophysics Data System (ADS)

    Gulpinar, Gul; Vatansever, Erol

    2012-03-01

    In this study, the temperature variations of the equilibrium and the non-equilibrium antiferromagnetic and ferromagnetic susceptibilities of a metamagnetic system are examined near the critical point. The kinetic equations describing the time dependencies of the total and staggered magnetizations are derived by utilizing linear response theory. In order to obtain dynamic magnetic relaxation behavior of the system, the stationary solutions of the kinetic equations in existence of sinusoidal staggered and physical external magnetic fields are performed. In addition, the static and dynamical mean field critical exponents are calculated in order to formulate the critical behavior of antiferromagnetic and ferromagnetic magnetic response of a metamagnetic system. Finally, a comparison of the findings of this study with previous theoretical and experimental studies is represented and it is shown that a good agreement is found with our results.

  8. Instantaneous velocity measurement of AC electroosmotic flows by laser induced fluorescence photobleaching anemometer with high temporal resolution

    NASA Astrophysics Data System (ADS)

    Zhao, Wei; Yang, Fang; Qiao, Rui; Wang, Guiren; Rui Qiao Collaboration

    2015-11-01

    Understanding the instantaneous response of flows to applied AC electric fields may help understand some unsolved issues in induced-charge electrokinetics and enhance performance of microfluidic devices. Since currently available velocimeters have difficulty in measuring velocity fluctuations with frequency higher than 1 kHz, most experimental studies so far focus only on the average velocity measurement in AC electrokinetic flows. Here, we present measurements of AC electroosmotic flow (AC-EOF) response time in microchannels by a novel velocimeter with submicrometer spatial resolution and microsecond temporal resolution, i.e. laser-induced fluorescence photobleaching anemometer (LIFPA). Several parameters affecting the AC-EOF response time to the applied electric signal were investigated, i.e. channel length, transverse position and solution conductivity. The experimental results show that the EOF response time under a pulsed electric field decreases with the reduction of the microchannel length, distance between the detection position to the wall and the conductivity of the solution. This work could provide a new powerful tool to measure AC electrokinetics and enhance our understanding of AC electrokinetic flows.

  9. The influence of radioactive decay on actinide magnetic susceptibility measurements obtained using the Evans method.

    PubMed

    Autillo, Matthieu; Kaden, Peter; Geist, Andreas; Guerin, Laetitia; Moisy, Philippe; Berthon, Claude

    2014-05-14

    In order to explain the higher magnetic susceptibility of some aquo actinide ions than predicted by Hund's rules, the molar magnetic susceptibilities of two americium isotopes ((241)Am and (243)Am) were measured using the Evans method. The results obtained show a growing change in the magnetic susceptibility with α and also a β(-) activity increase in solution. β(-) particle effects appear to be stronger than radicals formed by α particles on the experimental values. The temperature dependence of Am(iii) magnetic susceptibility has been observed but from experiments carried out here, it appears to be difficult to prove whether this effect arises from radicals or β(-). Finally, magnetic susceptibilities of americium recorded in different media (HClO4, HCl, and HNO3) have been compared to alpha and beta emissions' impact.

  10. Optical transmission versus ac magnetization measurements for monitoring colloidal Ni nanorod rotational dynamics

    NASA Astrophysics Data System (ADS)

    Gratz, M.; Tschöpe, A.

    2017-01-01

    Ni nanorods with an average length < 250 nm and diameter < 30 nm were synthesized using the AAO template method. The magnetization and optical transmission of nanorod colloidal dispersions in alternating magnetic fields were measured and analyzed with the objective of comparing the intrinsic Brownian relaxation times obtained with the two methods. The different physical origin of the measured signal, related to different moments of the orientation distribution function, and the non-linear effects expected for the large magnetic moments of the Ni nanorods at common field amplitudes required a comprehensive modelling. The time-dependent magnetization and optical transmission in ac magnetic fields was derived by numerical solution of the Fokker-Planck equation. The simulated time-dependent magnetization and optical transmission at a given frequency and field amplitude were analyzed analogous to experimental data to determine characteristic relaxation frequencies. Empirical relationships were derived which enabled extraction of the intrinsic Brownian relaxation time from the characteristic frequencies measured in the non-linear regime. Despite large differences in the characteristic frequencies obtained from magnetization and optical transmission measurements, the retrieved intrinsic Brownian relaxation times were found to agree well. The potential of ac magnetic field-dependent optical transmission for biosensing applications was demonstrated by monitoring the adsorption of the protein gelatine on the nanorod labels.

  11. Demagnetization Treatment of Remanent Composite Microspheres Studied by Alternating Current Susceptibility Measurements

    PubMed Central

    van Berkum, Susanne; Erné, Ben H.

    2013-01-01

    The magnetic remanence of silica microspheres with a low concentration of embedded cobalt ferrite nanoparticles is studied after demagnetization and remagnetization treatments. When the microspheres are dispersed in a liquid, alternating current (AC) magnetic susceptibility spectra reveal a constant characteristic frequency, corresponding to the rotational diffusion of the microparticles; this depends only on particle size and liquid viscosity, making the particles suitable as a rheological probe and indicating that interactions between the microspheres are weak. On the macroscopic scale, a sample with the dry microparticles is magnetically remanent after treatment in a saturating field, and after a demagnetization treatment, the remanence goes down to zero. The AC susceptibility of a liquid dispersion, however, characterizes the remanence on the scale of the individual microparticles, which does not become zero after demagnetization. The reason is that an individual microparticle contains only a relatively small number of magnetic units, so that even if they can be reoriented magnetically at random, the average vector sum of the nanoparticle dipoles is not negligible on the scale of the microparticle. In contrast, on the macroscopic scale, the demagnetization procedure randomizes the orientations of a macroscopic number of magnetic units, resulting in a remanent magnetization that is negligible compared to the saturation magnetization of the entire sample. PMID:24009021

  12. Susceptibility Measurements Near the He-3 Liquid-Gas Critical Point

    NASA Technical Reports Server (NTRS)

    Barmatz, Martin; Zhong, Fang; Hahn, Inseob

    2000-01-01

    An experiment is now being developed to measure both the linear susceptibility and specific heat at constant volume near the liquid-gas critical point of He-3 in a microgravity environment. An electrostriction technique for measuring susceptibility will be described. Initial electrostriction measurements were performed on the ground along the critical isochore in a 0.5 mm high measurement cell filled to within 0.1 % of the critical density. These measurements agreed with the susceptibility determined from pressure-density measurements along isotherms. The critical temperature, T(sub c), determined separately from specific heat and susceptibility measurements was self-consistent. Susceptibility measurements in the range t = T/T(sub c) - 1 > 10(exp -4)were fit to Chi(sup *)(sub T) = Gamma(sup +)t(exp -lambda)(1 + Gamma(sup +)(sub 1)t(sup delta). Best fit parameters for the asymptotic amplitude Gamma(sup +) and the first Wegner amplitude Gamma(sup +)(sub 1) will be presented and compared to previous measurements.

  13. Electrical resistivity and AC-calorimetric measurements of PrRu 4P 12 under pressure

    NASA Astrophysics Data System (ADS)

    Miyake, A.; Holmes, A. T.; Kagayama, T.; Shimizu, K.; Sekine, C.; Shirotani, I.; Kikuchi, D.; Sugawara, H.; Sato, H.

    2008-04-01

    We have studied the effect of pressure in the filled skutterudite PrRu 4P 12, which shows a metal-insulator (MI) transition at TMI=63 K, via simultaneous measurements of electrical resistivity ( ρ) and AC-calorimetry ( CAC). Schottky-like anomalies in CAC disappear under pressure, suggesting a change of the ground state. The resistivity below TMI is strongly suppressed with increasing pressure, in contrast to the weak pressure dependence of TMI. Above 10 GPa, ρ(T) shows metallic behavior with small anomalies at TMI. We discuss the likely change of ground state in PrRu 4P 12 with pressure from triplet to singlet.

  14. Interference susceptibility measurements for an MSK satellite communication link

    NASA Technical Reports Server (NTRS)

    Kerczewski, Robert J.; Fujikawa, Gene

    1992-01-01

    The results are presented of measurements of the degradation of an MSK satellite link due to modulated and CW (unmodulated) interference. These measurements were made using a hardware based satellite communication link simulator at NASA-Lewis. The results indicate the amount of bit error rate degradation caused by CW interference as a function of frequency and power level, and the degradation caused by adjacent channel and cochannel modulated interference as a function of interference power level. Results were obtained for both the uplink case (including satellite nonlinearity) and the downlink case (linear channel).

  15. Susceptibility measurements on the superconducting properties of Nb-Ge alloys

    NASA Technical Reports Server (NTRS)

    Rathz, T. J.

    1981-01-01

    A susceptibility apparatus to measure superconducting properties of samples made in the MSFC Drop Tube was used to measure the transition temperature (Tc) and susceptibilities of Nb and Nb Ge Alloys prepared in bulk spherical (2-4 mm diameter) form using a 32 m drop tube in which containerless low gravity solidification could take place. Results indicate that a drop tube processing environment was beneficial for increasing the Tc of the superconducting phase of the material over that of arc melted material. The increase in Tc is found to be related to the amount of solidification of the total sample that took place before reaching the bottom of the drop tube. In phase and quadrature phase measurements of the specimen's susceptibility indicated that some improvement in homogeneity takes place in drop tube processing. These phase measurements also indicated little or no shielding of a lower Tc phase by a higher Tc filamentary structure.

  16. Spectral response of atmospheric electric field measurements near AC high voltage power lines

    NASA Astrophysics Data System (ADS)

    Silva, H. G.; Matthews, J. C.; Wright, M. D.; Shallcross, D. E.

    2015-10-01

    To understand the influence of corona ion emission on the atmospheric electrical field, measurements were made near to two AC high voltage power lines. A JCI 131 field-mill recorded the atmospheric electric field over one year. Meteorological measurements were also taken. The data series is divided in four zones (dependent on wind direction): whole zones, Z0; zone 1, Z1; zone 2, Z2; zone 3, Z3. Z3 is the least affected by corona ion emission and for that reason it is used as a reference against Z1 and Z2, which are strongly influenced by this phenomena. Analysis was undertaken for all weather days and dry days only. The Lomb-Scargle strategy developed for unevenly spaced time-series is used to calculate the spectral response of the aforementioned zones. Only frequencies above 1 minute are considered.

  17. Practical considerations: making measurements of susceptibility, remanence and Q in the field

    NASA Astrophysics Data System (ADS)

    Schmidt, Phillip W.; Lackie, Mark A.

    2014-05-01

    Here we consider how measurements of magnetic susceptibility, magnetic remanence and Königsberger ratios (Q) can be made in the field. A basic refresher is given on how induced magnetisation differs from remanent magnetisation and what distinguishes multidomain from single domain behaviour of magnetite particles. The approximation of an infinite half-space, which is the usual assumption for using most handheld susceptibility meters, is experimentally investigated and it is found that a block 100 × 100 × 60 mm is the minimum requirement for the meters tested here. The susceptibilities of chips of a dacite, an andesite and a spilite (altered basalt) are also experimentally investigated for a range of chip sizes from a few mm down to 200 μm. The relationship is quite flat until very small grain sizes are reached where the susceptibility either decreases or increases, which is interpreted as an indication of the grain-size fraction where the magnetite resides. Making susceptibility measurements on bags of rock chips is investigated and guidelines given. The temperature of susceptibility meters is also found to be a factor and five meters have been tested for temperatures from 0°C to 50°C, the stated operating range of most meters. Finally Breiner's method to separate induced magnetisation from remanent magnetisation using a field magnetometer is discussed. A new fluxgate based pendulum instrument to allow a more controlled implementation of Breiner's method is also described.

  18. Spectral Measurements from the Optical Emission of the A.C. Plasma Anemometer

    NASA Astrophysics Data System (ADS)

    Matlis, Eric; Marshall, Curtis; Corke, Thomas; Gogineni, Sivaram

    2015-11-01

    The optical emission properties of a new class of AC-driven flow sensors based on a glow discharge (plasma) is presented. These results extend the utility of the plasma sensor that has recently been developed for measurements in high-enthalpy flows. The plasma sensor utilizes a high frequency (1MHz) AC discharge between two electrodes as the main sensing element. The voltage drop across the discharge correlates to changes in the external flow which can be calibrated for mass-flux (ρU) or pressure depending on the design of the electrodes and orientation relative to the free-stream flow direction. Recent experiments examine the potential for spectral analysis of the optical emission of the discharge to provide additional insight to the flow field. These experiments compare the optical emission of the plasma to emission from breakdown due to an ND:YAG laser. The oxygen 777.3 nm band in particular is a focus of interest as a marker for the determination of gas density.

  19. Resistivity and AC calorimetry measurements on CeNiGe2 under pressure

    NASA Astrophysics Data System (ADS)

    Holmes, A. T.; Muramatsu, T.; Miyake, A.; Kaczorowski, D.; Bukowski, Z.; Kagayama, T.; Shimizu, K.

    2007-03-01

    We present resistivity and AC calorimetry measurements of single crystalline CeNiGe2 under high pressure and low temperature in a diamond anvil cell. CeNiGe2 is a highly anisotropic, antiferromagnetic Kondo system at ambient pressure, located close to the boundary with non-magnetic systems. It has two ordering temperatures, T=3.9 K and T=3.2 K, which are suppressed under pressure. Between 0.7 and 1.4 GPa only a single transition was identified, with TN reaching 1.9 K by 1.4 GPa. At 1.9 GPa two transitions could again be seen by AC calorimetry at 2.0 and 1.3 K, accompanied by a qualitative change in the behaviour of the resistivity. The Sommerfeld coefficient showed a maximum of 755 mJ mol-1 K-2 at 1.4 GPa, up from 448 mJ mol-1 K-2 at close to ambient pressure. The residual resistivity was found to decrease sharply above 1.4 GPa after an initial increase with pressure.

  20. DC and AC Electric Field Measurements by Spin-Plane Double Probes Onboard MMS

    NASA Astrophysics Data System (ADS)

    Lindqvist, P. A.; Marklund, G. T.; Khotyaintsev, Y. V.; Ergun, R. E.; Goodrich, K.; Torbert, R. B.; Argall, M. R.; Nakamura, R.

    2015-12-01

    The four spacecraft of the NASA Magnetospheric Multiscale mission (MMS) were launched on 12 March 2015 into a 1.2 x 12 Re equatorial orbit to study energy conversion processes in Earth's magnetosphere. After a 5-month commissioning period the first scientific phase starts on 1 September as the orbit enters the dusk magnetopause region. The Spin-plane Double Probe electric field instrument (SDP), part of the electric and magnetic fields instrument suite FIELDS, measures the electric field in the range 0.3 - 500 mV/m with a continuous time resolution up to 8192 samples/s. The instrument features adjustable bias currents and guard voltages to optimize the measurement performance. SDP also measures the spacecraft potential, which can be controlled by the Active Spacecraft Potential Control (ASPOC) ion emitter, and under certain conditions can be used to determine plasma density. We present observations of DC and AC electric fields in different plasma regions covered by MMS since launch including the night side flow braking region, reconnection regions at the dusk and dayside magnetopause, and in the magnetosheath. We compare the electric field measurements by SDP to other, independent determinations of the electric field, in particular by the Electron Drift Instrument (EDI), in order to assess the accuracy of the electric field measurement under different plasma conditions. We also study the influence of the currents emitted by ASPOC and EDI on the SDP measurements.

  1. An AC phase measuring interferometer for measuring dn/dT of fused silica and calcium fluoride at 193 nm

    SciTech Connect

    Shagam, R.N.

    1998-09-01

    A novel method for the measurement of the change in index of refraction vs. temperature (dn/dT) of fused silica and calcium fluoride at the 193 nm wavelength has been developed in support of thermal modeling efforts for the development of 193 nm-based photolithographic exposure tools. The method, based upon grating lateral shear interferometry, uses a transmissive linear grating to divide a 193 nm laser beam into several beam paths by diffraction which propagate through separate identical material samples. One diffracted order passing through one sample overlaps the undiffracted beam from a second sample and forms interference fringes dependent upon the optical path difference between the two samples. Optical phase delay due to an index change from heating one of the samples causes the interference fringes to change sinusoidally with phase. The interferometer also makes use of AC phase measurement techniques through lateral translation of the grating. Results for several samples of fused silica and calcium fluoride are demonstrated.

  2. AC magnetic measurement of LiFeAs at pressures up to 5.2 GPa: The relation between T c and the structural parameters

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Shuhei; Yamaguchi, Nobuhiro; Mito, Masaki; Deguchi, Hiroyuki; Baker, Peter. J.; Blundell, Stephen. J.; Pitcher, Michael. J.; Parker, Dinah. R.; Clarke, Simon. J.

    2013-08-01

    The pressure effects on the 111-type Fe-based superconductor LiFeAs were investigated through AC susceptibility measurements and X-ray diffraction experiments, and revealed a correlation between the superconducting transition temperature ( T c ) and the As-Fe-As bond angle ( α) rather than the height of As from the Fe layers ( h As). As the pressure was increased, T c of 17 K at P = 0 GPa decreased down to 10 K at P = 5.2 GPa. According to a previous report from an X-ray diffraction experiment, α changes from 101.5° at 0 GPa to 97.8° at 17 GPa. The obtained change in T c is consistent with Lee et al.'s plot of T c as a function of α, and from this result, we conclude that T c will fall to zero at around α = 98°.

  3. Impact of grass cover on the magnetic susceptibility measurements for assessing metal contamination in urban topsoil.

    PubMed

    Golden, Nessa; Zhang, Chaosheng; Potito, Aaron P; Gibson, Paul J; Bargary, Norma; Morrison, Liam

    2017-03-02

    In recent decades, magnetic susceptibility monitoring has developed as a useful technique in environmental pollution studies, particularly metal contamination of soil. This study provides the first ever examination of the effects of grass cover on magnetic susceptibility (MS) measurements of underlying urban soils. Magnetic measurements were taken in situ to determine the effects on κ (volume magnetic susceptibility) when the grass layer was present (κ(grass)) and after the grass layer was trimmed down to the root (κ(no grass)). Height of grass was recorded in situ at each grid point. Soil samples (n=185) were collected and measurements of mass specific magnetic susceptibility (χ) were performed in the laboratory and frequency dependence (χfd%) calculated. Metal concentrations (Pb, Cu, Zn and Fe) in the soil samples were determined and a gradiometry survey carried out in situ on a section of the study area. Significant correlations were found between each of the MS measurements and the metal content of the soil at the p<0.01 level. Spatial distribution maps were created using Inverse Distance Weighting (IDW) and Local Indicators of Spatial Association (LISA) to identify common patterns. κ(grass) (ranged from 1.67 to 301.00×10(-5) SI) and κ(no grass) (ranged from 2.08 to 530.67×10(-5) SI) measured in situ are highly correlated [r=0.966, n=194, p<0.01]. The volume susceptibility datasets in the presence and absence of grass coverage share a similar spatial distribution pattern. This study re-evaluates in situ κ monitoring techniques and the results suggest that the removal of grass coverage prior to obtaining in situ κ measurements of urban soil is unnecessary. This layer does not impede the MS sensor from accurately measuring elevated κ in soils, and therefore κ measurements recorded with grass coverage present can be reliably used to identify areas of urban soil metal contamination.

  4. Developing Test Apparatus and Measurements of AC Loss of High Temperature Superconductors

    DTIC Science & Technology

    2012-11-01

    superconducting wires can be very effectively reduced in proportion of the number of filaments. The oxygen annealing eliminates the residual coupling losses by...made out of YBCO superconducting wires were studied, confirming the simulation method used to calculate and predict AC loss and hysteretic effects of... oxygen annealing were tested in order to determine their effect on AC loss reduction. Results showed that the AC loss in multifilament

  5. A Comparative Study on Pre-Standardization of Total AC Loss Measurements for Oxide-Superconducting Tapes in Japan

    NASA Astrophysics Data System (ADS)

    Funaki, Kazuo; Tanaka, Yasuzo; Osamura, Kozo

    2006-06-01

    We have been considering about standard methods to estimate total AC loss in oxide-superconducting tapes under practical electromagnetic conditions in future power devices. We adopt 4 candidates of the standard methods to measure the AC loss in superconducting wires exposed to AC transverse magnetic field and alternating transport current. We also introduce two pickup coil methods for comparative references of external magnetic field loss. The specimen is a Bi-2223 Ag-alloy-sheathed multifilamentary tape without twisting. 60-100 mm short pieces of specimen were cut from a terminal of a 50 m long specimen for 4 in 6 methods. A double-layer non-inductive coiled specimen was also prepared from the long specimen for the other 2 methods. The scattering in AC loss property among the short specimens prepared is less than 1% in the perpendicular field with the amplitude from 0.01 to 0.1 T at 10 Hz. The scattering in repeated measurements of the loss during 3 heat cycles is within 2-3%, which almost corresponds to that of the critical current in the long specimen. We processed the results measured by each method for the external field loss and total AC loss, summarized dispersion among the observed results of all methods and discussed about the candidates of the standard methods.

  6. A study of the spin-gaps in the organic conductor Perylene2[Pt(mnt)2] with the application of high magnetic field using an inductive AC susceptibility method

    NASA Astrophysics Data System (ADS)

    Winter, Laurel; Brooks, James; Schlottmann, Pedro; Almeida, Manuel; Benjamin, Shermane; Bourbonnais, Claude

    2014-03-01

    To further understand the spin-charge coupling present in the dual-chain organic conductor Per2[Pt(mnt)2] we utilized an inductive ac susceptibility method to study the spin-Peierls (SP) ordered state.2 Besides reaffirming the coexistence of the SP-CDW below 8 K and 20 T, our measurements also showed the emergence of a second spin-gapped phase above 20 T that coincides with the previous observed field-induced insulating phase. Our results provide support for the continued coupling of the charge and spin order parameters even in high magnetic fields and hints at the possibility of further spin and charge gaps above 45 T.2 L.E. Winter, J.S. Brooks, P. Schlottmann, M. Almeida, S. Benjamin, and C, Bourbonnais, Europhys. Lett., 103 (2013) 37008. This work was supported by NSF-DMR 1005293 and the NHMFL is supported by the NSF-DMR-1157490 and the State of Florida. PS is supported by DOE under grant DE-FG02-98ER45707.

  7. Quantitative Thermal Microscopy Measurement with Thermal Probe Driven by dc+ac Current

    NASA Astrophysics Data System (ADS)

    Bodzenta, Jerzy; Juszczyk, Justyna; Kaźmierczak-Bałata, Anna; Firek, Piotr; Fleming, Austin; Chirtoc, Mihai

    2016-07-01

    Quantitative thermal measurements with spatial resolution allowing the examination of objects of submicron dimensions are still a challenging task. The quantity of methods providing spatial resolution better than 100 nm is very limited. One of them is scanning thermal microscopy (SThM). This method is a variant of atomic force microscopy which uses a probe equipped with a temperature sensor near the apex. Depending on the sensor current, either the temperature or the thermal conductivity distribution at the sample surface can be measured. However, like all microscopy methods, the SThM gives only qualitative information. Quantitative measuring methods using SThM equipment are still under development. In this paper, a method based on simultaneous registration of the static and the dynamic electrical resistances of the probe driven by the sum of dc and ac currents, and examples of its applications are described. Special attention is paid to the investigation of thin films deposited on thick substrates. The influence of substrate thermal properties on the measured signal and its dependence on thin film thermal conductivity and film thickness are analyzed. It is shown that in the case where layer thicknesses are comparable or smaller than the probe-sample contact diameter, a correction procedure is required to obtain actual thermal conductivity of the layer. Experimental results obtained for thin SiO2 and BaTiO_{3 }layers with thicknesses in the range from 11 nm to 100 nm are correctly confirmed with this approach.

  8. Experimentally Measured Susceptibility to Peer Influence and Adolescent Sexual Behavior Trajectories: A Preliminary Study

    ERIC Educational Resources Information Center

    Choukas-Bradley, Sophia; Giletta, Matteo; Widman, Laura; Cohen, Geoffrey L.; Prinstein, Mitchell J.

    2014-01-01

    A performance-based measure of peer influence susceptibility was examined as a moderator of the longitudinal association between peer norms and trajectories of adolescents' number of sexual intercourse partners. Seventy-one 9th grade adolescents (52% female) participated in an experimental "chat room" paradigm involving…

  9. Magnetic susceptibility measurement of solid oxygen at pressures up to 3.3 GPa

    NASA Astrophysics Data System (ADS)

    Mito, M.; Yamaguchi, S.; Tsuruda, H.; Deguchi, H.; Ishizuka, M.

    2014-01-01

    The magnetic susceptibility of solid oxygen had long been observed only in the restricted pressure region below 0.8 GPa. We succeeded in extending the pressure region up to 3.3 GPa by clamping condensed oxygen in the sample chamber of a miniature diamond anvil cell and measuring the dc magnetic susceptibility using a superconducting quantum interference device magnetometer. In this experiment, the well-known α-β and β-γ transitions are observed in the phase diagram, suggesting consistency with the previous results of X-ray and Raman studies. In addition, a new magnetic anomaly is observed in the β phase.

  10. Magnetic susceptibility measurement of solid oxygen at pressures up to 3.3 GPa

    SciTech Connect

    Mito, M. Yamaguchi, S.; Tsuruda, H.; Deguchi, H.; Ishizuka, M.

    2014-01-07

    The magnetic susceptibility of solid oxygen had long been observed only in the restricted pressure region below 0.8 GPa. We succeeded in extending the pressure region up to 3.3 GPa by clamping condensed oxygen in the sample chamber of a miniature diamond anvil cell and measuring the dc magnetic susceptibility using a superconducting quantum interference device magnetometer. In this experiment, the well-known α–β and β–γ transitions are observed in the phase diagram, suggesting consistency with the previous results of X-ray and Raman studies. In addition, a new magnetic anomaly is observed in the β phase.

  11. Cross-evidence for hypnotic susceptibility through nonlinear measures on EEGs of non-hypnotized subjects

    NASA Astrophysics Data System (ADS)

    Chiarucci, Riccardo; Madeo, Dario; Loffredo, Maria I.; Castellani, Eleonora; Santarcangelo, Enrica L.; Mocenni, Chiara

    2014-07-01

    Assessment of hypnotic susceptibility is usually obtained through the application of psychological instruments. A satisfying classification obtained through quantitative measures is still missing, although it would be very useful for both diagnostic and clinical purposes. Aiming at investigating the relationship between the cortical brain activity and the hypnotic susceptibility level, we propose the combined use of two methodologies - Recurrence Quantification Analysis and Detrended Fluctuation Analysis - both inherited from nonlinear dynamics. Indicators obtained through the application of these techniques to EEG signals of individuals in their ordinary state of consciousness allowed us to obtain a clear discrimination between subjects with high and low susceptibility to hypnosis. Finally a neural network approach was used to perform classification analysis.

  12. Cross-evidence for hypnotic susceptibility through nonlinear measures on EEGs of non-hypnotized subjects

    PubMed Central

    Chiarucci, Riccardo; Madeo, Dario; Loffredo, Maria I.; Castellani, Eleonora; Santarcangelo, Enrica L.; Mocenni, Chiara

    2014-01-01

    Assessment of hypnotic susceptibility is usually obtained through the application of psychological instruments. A satisfying classification obtained through quantitative measures is still missing, although it would be very useful for both diagnostic and clinical purposes. Aiming at investigating the relationship between the cortical brain activity and the hypnotic susceptibility level, we propose the combined use of two methodologies - Recurrence Quantification Analysis and Detrended Fluctuation Analysis - both inherited from nonlinear dynamics. Indicators obtained through the application of these techniques to EEG signals of individuals in their ordinary state of consciousness allowed us to obtain a clear discrimination between subjects with high and low susceptibility to hypnosis. Finally a neural network approach was used to perform classification analysis. PMID:25002038

  13. Ac irreversibility line of bismuth-based high temperature superconductors

    SciTech Connect

    Mehdaoui, A.; Beille, J.; Berling, D.; Loegel, B.; Noudem, J.G.; Tournier, R.

    1997-09-01

    We discuss the magnetic properties of lead doped Bi-2223 bulk samples obtained through combined magnetic melt texturing and hot pressing (MMTHP). The ac complex susceptibility measurements are achieved over a broad ac field range (1 Oe{lt}h{sub ac}{lt}100 Oe) and show highly anisotropic properties. The intergranular coupling is improved in the direction perpendicular to the applied stress and magnetic field direction, and an intragranular loss peak is observed for the first time. A comparison is made with other bismuth-based compounds and it is shown that the MMTHP process shifts the ac irreversibility line (ac IL) toward higher fields. It is also shown that all the ac IL{close_quote}s for quasi 2D bismuth-based compounds show a nearly quadratic temperature dependence and deviate therefore strongly from the linear behavior observed in quasi 3D compounds and expected from a critical state model.{copyright} {ital 1997 Materials Research Society.}

  14. Model simulations of the first aerosol indirect effect and comparison of cloud susceptibility fo satellite measurements

    SciTech Connect

    Chuang, C; Penner, J E; Kawamoto, K

    2002-03-08

    Present-day global anthropogenic emissions contribute more than half of the mass in submicron particles primarily due to sulfate and carbonaceous aerosol components derived from fossil fuel combustion and biomass burning. These anthropogenic aerosols modify the microphysics of clouds by serving as cloud condensation nuclei (CCN) and enhance the reflectivity of low-level water clouds, leading to a cooling effect on climate (the Twomey effect or first indirect effect). The magnitude of the first aerosol indirect effect is associated with cloud frequency as well as a quantity representing the sensitivity of cloud albedo to changes in cloud drop number concentration. This quantity is referred to as cloud susceptibility [Twomey, 1991]. Analysis of satellite measurements demonstrates that marine stratus clouds are likely to be of higher susceptibility than continental clouds because of their lower number concentrations of cloud drops [Platnick and Twomey, 1994]. Here, we use an improved version of the fully coupled climate/chemistry model [Chuang et al., 1997] to calculate the global concentrations Of sulfate, dust, sea salt, and carbonaceous aerosols (biomass smoke and fossil fuel organic matter and black carbon). We investigated the impact of anthropogenic aerosols on cloud susceptibility and calculated the associated changes of shortwave radiative fluxes at the top of the atmosphere. We also examined the correspondence between the model simulation of cloud susceptibility and that inferred from satellite measurements to test whether our simulated aerosol concentrations and aerosol/cloud interactions give a faithful representation of these features.

  15. High-Resolution ac Measurements of the Hall Effect in Organic Field-Effect Transistors

    NASA Astrophysics Data System (ADS)

    Chen, Y.; Yi, H. T.; Podzorov, V.

    2016-03-01

    We describe a high resolving power technique for Hall-effect measurements, efficient in determining Hall mobility and carrier density in organic field-effect transistors and other low-mobility systems. We utilize a small low-frequency ac magnetic field (Brms<0.25 T ) and a phase-sensitive (lock-in) detection of Hall voltage, with the necessary corrections for Faraday induction. This method significantly enhances the signal-to-noise ratio and eliminates the necessity of using high magnetic fields in Hall-effect studies. With the help of this method, we are able to obtain the Hall mobility and carrier density in organic transistors with a mobility as low as μ ˜0.3 cm2 V-1 s-1 by using a compact desktop apparatus and low magnetic fields. We find a good agreement between Hall-effect and electric-field-effect measurements, indicating that, contrary to the common belief, certain organic semiconductors with mobilities below 1 cm2 V-1 s-1 can still exhibit a fully developed, band-semiconductor-like Hall effect, with the Hall mobility and carrier density matching those obtained in longitudinal transistor measurements. This suggests that, even when μ <1 cm2 V-1 s-1 , charges in organic semiconductors can still behave as delocalized coherent carriers. This technique paves the way to ubiquitous Hall-effect studies in a wide range of low-mobility materials and devices, where it is typically very difficult to resolve the Hall effect even in very high dc magnetic fields.

  16. Simultaneous measurements of somatosensory evoked AC and near-DC MEG signals.

    PubMed

    Körber, Rainer; Curio, Gabriel; Hartwig, Stefan; Hilschenz, Ingo; Höfner, Nora; Scheer, Hans-Jürgen; Trahms, Lutz; Voigt, Jens; Burghoff, Martin

    2011-04-01

    Magnetoencephalography measurements of somatosensory evoked brain activity taken inside an extremely magnetically shielded room are reported. The massive low frequency shielding in combination with a high sampling rate enabled the simultaneous observation of AC and near-DC effects. Neuronal activation was achieved by repetitive electrostimulation of the right median nerve above motor threshold using repetition rates from 3 Hz to 12 Hz. Stimulation sequences lasted for 10 s and were interspersed with periods of rest of equal length. The recorded magnetic fields, inferred for the N20m and a sustained near-DC component, revealed mainly dipolar patterns with mutually rotated orientations with angles of rotation of 30° and 75°. At the start of the stimulation we observed a fast rise within 100 ms in the evoked magnetic near-DC fields for which a maximum equivalent current dipole strength of 65 nAm was obtained. The sustained fields decayed by a factor of ∼4 to a lower DC-level B(γ) with a time constant τ of order of seconds. For 12 Hz repetition rate B(γ) was decreased. We suggest that the sustained neuronal activity evoked by repetitive electrostimulation could provide a suitable scheme to realize the direct detection of DC effects of neuronal currents via low field magnetic resonance.

  17. Effect of carbon substitution on low magnetic field AC losses in MgB 2 single crystals

    NASA Astrophysics Data System (ADS)

    Ciszek, M.; Rogacki, K.; Karpiński, J.

    2011-11-01

    The DC magnetization and AC magnetic susceptibilities were measured for MgB2 single crystals, unsubstituted and carbon substituted with the composition of Mg(B0.94C0.06)2. AC magnetic losses were derived from the AC susceptibility data as a function of the AC amplitude and the DC bias magnetic field. From the DC magnetization loops critical current densities were derived as a function of temperature and DC field. Results show that the substitution with carbon decreases critical current densities at low external magnetic fields, in contrast to the well known effect of an increase of the critical current densities at higher magnetic fields.

  18. Novel Associations between Common Breast Cancer Susceptibility Variants and Risk-Predicting Mammographic Density Measures.

    PubMed

    Stone, Jennifer; Thompson, Deborah J; Dos Santos Silva, Isabel; Scott, Christopher; Tamimi, Rulla M; Lindstrom, Sara; Kraft, Peter; Hazra, Aditi; Li, Jingmei; Eriksson, Louise; Czene, Kamila; Hall, Per; Jensen, Matt; Cunningham, Julie; Olson, Janet E; Purrington, Kristen; Couch, Fergus J; Brown, Judith; Leyland, Jean; Warren, Ruth M L; Luben, Robert N; Khaw, Kay-Tee; Smith, Paula; Wareham, Nicholas J; Jud, Sebastian M; Heusinger, Katharina; Beckmann, Matthias W; Douglas, Julie A; Shah, Kaanan P; Chan, Heang-Ping; Helvie, Mark A; Le Marchand, Loic; Kolonel, Laurence N; Woolcott, Christy; Maskarinec, Gertraud; Haiman, Christopher; Giles, Graham G; Baglietto, Laura; Krishnan, Kavitha; Southey, Melissa C; Apicella, Carmel; Andrulis, Irene L; Knight, Julia A; Ursin, Giske; Alnaes, Grethe I Grenaker; Kristensen, Vessela N; Borresen-Dale, Anne-Lise; Gram, Inger Torhild; Bolla, Manjeet K; Wang, Qin; Michailidou, Kyriaki; Dennis, Joe; Simard, Jacques; Pharoah, Paul; Dunning, Alison M; Easton, Douglas F; Fasching, Peter A; Pankratz, V Shane; Hopper, John L; Vachon, Celine M

    2015-06-15

    Mammographic density measures adjusted for age and body mass index (BMI) are heritable predictors of breast cancer risk, but few mammographic density-associated genetic variants have been identified. Using data for 10,727 women from two international consortia, we estimated associations between 77 common breast cancer susceptibility variants and absolute dense area, percent dense area and absolute nondense area adjusted for study, age, and BMI using mixed linear modeling. We found strong support for established associations between rs10995190 (in the region of ZNF365), rs2046210 (ESR1), and rs3817198 (LSP1) and adjusted absolute and percent dense areas (all P < 10(-5)). Of 41 recently discovered breast cancer susceptibility variants, associations were found between rs1432679 (EBF1), rs17817449 (MIR1972-2: FTO), rs12710696 (2p24.1), and rs3757318 (ESR1) and adjusted absolute and percent dense areas, respectively. There were associations between rs6001930 (MKL1) and both adjusted absolute dense and nondense areas, and between rs17356907 (NTN4) and adjusted absolute nondense area. Trends in all but two associations were consistent with those for breast cancer risk. Results suggested that 18% of breast cancer susceptibility variants were associated with at least one mammographic density measure. Genetic variants at multiple loci were associated with both breast cancer risk and the mammographic density measures. Further understanding of the underlying mechanisms at these loci could help identify etiologic pathways implicated in how mammographic density predicts breast cancer risk.

  19. Multiplexed sensing based on Brownian relaxation of magnetic nanoparticles using a compact AC susceptometer

    NASA Astrophysics Data System (ADS)

    Park, Kyoungchul; Harrah, Tim; Goldberg, Edward B.; Guertin, Robert P.; Sonkusale, Sameer

    2011-02-01

    A novel multiplexed sensing scheme based on the measurement of the magnetic susceptibility of the affinity captured target molecules on magnetic nanoparticles in liquid suspension is proposed. The AC magnetic susceptibility provides a measurement of Brownian relaxation behavior of biomolecules bound to magnetic nanoparticles (MNPs) that is related to its hydrodynamic size. A room temperature, compact AC susceptometer is designed and developed to measure complex AC magnetic susceptibility of such magnetic nanoparticles. The AC susceptometer exhibits high sensitivity in magnetic fields as low as 10 µT for 1 mg ml-1 concentration and 5 µl volume, and is fully software programmable. The capability of biological sensing using the proposed scheme has been demonstrated in proof of principle using the binding of biotinylated horseradish peroxidase (HRP) to streptavidin-coated MNPs. The proposed technique and instrument are readily compatible with lab-on-chip applications for point-of-care medical applications.

  20. Measurement of the direct C P -violating parameter AC P in the decay D+→K-π+π+

    NASA Astrophysics Data System (ADS)

    Abazov, V. M.; Abbott, B.; Acharya, B. S.; Adams, M.; Adams, T.; Agnew, J. P.; Alexeev, G. D.; Alkhazov, G.; Alton, A.; Askew, A.; Atkins, S.; Augsten, K.; Avila, C.; Badaud, F.; Bagby, L.; Baldin, B.; Bandurin, D. V.; Banerjee, S.; Barberis, E.; Baringer, P.; Bartlett, J. F.; Bassler, U.; Bazterra, V.; Bean, A.; Begalli, M.; Bellantoni, L.; Beri, S. B.; Bernardi, G.; Bernhard, R.; Bertram, I.; Besançon, M.; Beuselinck, R.; Bhat, P. C.; Bhatia, S.; Bhatnagar, V.; Blazey, G.; Blessing, S.; Bloom, K.; Boehnlein, A.; Boline, D.; Boos, E. E.; Borissov, G.; Borysova, M.; Brandt, A.; Brandt, O.; Brock, R.; Bross, A.; Brown, D.; Bu, X. B.; Buehler, M.; Buescher, V.; Bunichev, V.; Burdin, S.; Buszello, C. P.; Camacho-Pérez, E.; Casey, B. C. K.; Castilla-Valdez, H.; Caughron, S.; Chakrabarti, S.; Chan, K. M.; Chandra, A.; Chapon, E.; Chen, G.; Cho, S. W.; Choi, S.; Choudhary, B.; Cihangir, S.; Claes, D.; Clutter, J.; Cooke, M.; Cooper, W. E.; Corcoran, M.; Couderc, F.; Cousinou, M.-C.; Cutts, D.; Das, A.; Davies, G.; de Jong, S. J.; De La Cruz-Burelo, E.; Déliot, F.; Demina, R.; Denisov, D.; Denisov, S. P.; Desai, S.; Deterre, C.; DeVaughan, K.; Diehl, H. T.; Diesburg, M.; Ding, P. F.; Dominguez, A.; Dubey, A.; Dudko, L. V.; Duperrin, A.; Dutt, S.; Eads, M.; Edmunds, D.; Ellison, J.; Elvira, V. D.; Enari, Y.; Evans, H.; Evdokimov, V. N.; Fauré, A.; Feng, L.; Ferbel, T.; Fiedler, F.; Filthaut, F.; Fisher, W.; Fisk, H. E.; Fortner, M.; Fox, H.; Fuess, S.; Garbincius, P. H.; Garcia-Bellido, A.; García-González, J. A.; Gavrilov, V.; Geng, W.; Gerber, C. E.; Gershtein, Y.; Ginther, G.; Gogota, O.; Golovanov, G.; Grannis, P. D.; Greder, S.; Greenlee, H.; Grenier, G.; Gris, Ph.; Grivaz, J.-F.; Grohsjean, A.; Grünendahl, S.; Grünewald, M. W.; Guillemin, T.; Gutierrez, G.; Gutierrez, P.; Haley, J.; Han, L.; Harder, K.; Harel, A.; Hauptman, J. M.; Hays, J.; Head, T.; Hebbeker, T.; Hedin, D.; Hegab, H.; Heinson, A. P.; Heintz, U.; Hensel, C.; Heredia-De La Cruz, I.; Herner, K.; Hesketh, G.; Hildreth, M. D.; Hirosky, R.; Hoang, T.; Hobbs, J. D.; Hoeneisen, B.; Hogan, J.; Hohlfeld, M.; Holzbauer, J. L.; Howley, I.; Hubacek, Z.; Hynek, V.; Iashvili, I.; Ilchenko, Y.; Illingworth, R.; Ito, A. S.; Jabeen, S.; Jaffré, M.; Jayasinghe, A.; Jeong, M. S.; Jesik, R.; Jiang, P.; Johns, K.; Johnson, E.; Johnson, M.; Jonckheere, A.; Jonsson, P.; Joshi, J.; Jung, A. W.; Juste, A.; Kajfasz, E.; Karmanov, D.; Katsanos, I.; Kaur, M.; Kehoe, R.; Kermiche, S.; Khalatyan, N.; Khanov, A.; Kharchilava, A.; Kharzheev, Y. N.; Kiselevich, I.; Kohli, J. M.; Kozelov, A. V.; Kraus, J.; Kumar, A.; Kupco, A.; Kurča, T.; Kuzmin, V. A.; Lammers, S.; Lebrun, P.; Lee, H. S.; Lee, S. W.; Lee, W. M.; Lei, X.; Lellouch, J.; Li, D.; Li, H.; Li, L.; Li, Q. Z.; Lim, J. K.; Lincoln, D.; Linnemann, J.; Lipaev, V. V.; Lipton, R.; Liu, H.; Liu, Y.; Lobodenko, A.; Lokajicek, M.; Lopes de Sa, R.; Luna-Garcia, R.; Lyon, A. L.; Maciel, A. K. A.; Madar, R.; Magaña-Villalba, R.; Malik, S.; Malyshev, V. L.; Mansour, J.; Martínez-Ortega, J.; McCarthy, R.; McGivern, C. L.; Meijer, M. M.; Melnitchouk, A.; Menezes, D.; Mercadante, P. G.; Merkin, M.; Meyer, A.; Meyer, J.; Miconi, F.; Mondal, N. K.; Mulhearn, M.; Nagy, E.; Narain, M.; Nayyar, R.; Neal, H. A.; Negret, J. P.; Neustroev, P.; Nguyen, H. T.; Nunnemann, T.; Orduna, J.; Osman, N.; Osta, J.; Pal, A.; Parashar, N.; Parihar, V.; Park, S. K.; Partridge, R.; Parua, N.; Patwa, A.; Penning, B.; Perfilov, M.; Peters, Y.; Petridis, K.; Petrillo, G.; Pétroff, P.; Pleier, M.-A.; Podstavkov, V. M.; Popov, A. V.; Prewitt, M.; Price, D.; Prokopenko, N.; Qian, J.; Quadt, A.; Quinn, B.; Ratoff, P. N.; Razumov, I.; Ripp-Baudot, I.; Rizatdinova, F.; Rominsky, M.; Ross, A.; Royon, C.; Rubinov, P.; Ruchti, R.; Sajot, G.; Sánchez-Hernández, A.; Sanders, M. P.; Santos, A. S.; Savage, G.; Savitskyi, M.; Sawyer, L.; Scanlon, T.; Schamberger, R. D.; Scheglov, Y.; Schellman, H.; Schwanenberger, C.; Schwienhorst, R.; Sekaric, J.; Severini, H.; Shabalina, E.; Shary, V.; Shaw, S.; Shchukin, A. A.; Simak, V.; Skubic, P.; Slattery, P.; Smirnov, D.; Snow, G. R.; Snow, J.; Snyder, S.; Söldner-Rembold, S.; Sonnenschein, L.; Soustruznik, K.; Stark, J.; Stoyanova, D. A.; Strauss, M.; Suter, L.; Svoisky, P.; Titov, M.; Tokmenin, V. V.; Tsai, Y.-T.; Tsybychev, D.; Tuchming, B.; Tully, C.; Uvarov, L.; Uvarov, S.; Uzunyan, S.; Van Kooten, R.; van Leeuwen, W. M.; Varelas, N.; Varnes, E. W.; Vasilyev, I. A.; Verkheev, A. Y.; Vertogradov, L. S.; Verzocchi, M.; Vesterinen, M.; Vilanova, D.; Vokac, P.; Wahl, H. D.; Wang, M. H. L. S.; Warchol, J.; Watts, G.; Wayne, M.; Weichert, J.; Welty-Rieger, L.; Williams, M. R. J.; Wilson, G. W.; Wobisch, M.; Wood, D. R.; Wyatt, T. R.; Xie, Y.; Yamada, R.; Yang, S.; Yasuda, T.; Yatsunenko, Y. A.; Ye, W.; Ye, Z.; Yin, H.; Yip, K.; Youn, S. W.; Yu, J. M.; Zennamo, J.; Zhao, T. G.; Zhou, B.; Zhu, J.; Zielinski, M.; Zieminska, D.; Zivkovic, L.; D0 Collaboration

    2014-12-01

    We measure the direct C P -violating parameter AC P for the decay of the charged charm meson, D+→K-π+π+ (and charge conjugate), using the full 10.4 fb-1 sample of p p ¯ collisions at √{s }=1.96 TeV collected by the D0 detector at the Fermilab Tevatron collider. We extract the raw reconstructed charge asymmetry by fitting the invariant mass distributions for the sum and difference of charge-specific samples. This quantity is then corrected for detector-related asymmetries using data-driven methods and for possible physics asymmetries (from B →D processes) using input from Monte Carlo simulation. We measure AC P=[-0.16 ±0.15 (stat)±0.09 (syst)]% , which is consistent with zero, as expected from the standard model prediction of C P conservation, and is the most precise measurement of this quantity to date.

  1. Noncontact technique for measuring the electrical resistivity and magnetic susceptibility of electrostatically levitated materials.

    PubMed

    Rustan, G E; Spyrison, N S; Kreyssig, A; Prozorov, R; Goldman, A I

    2012-10-01

    We describe the development of a new method for measuring the electrical resistivity and magnetic susceptibility of high temperature liquids and solids. The technique combines a tunnel diode oscillator with an electrostatic levitation furnace to perform noncontact measurements on spherical samples 2-3 mm in diameter. The tank circuit of the oscillator is inductively coupled to the sample, and measurements of the oscillator frequency as a function of sample temperature can be translated into changes in the sample's electrical resistivity and magnetic susceptibility. Particular emphasis is given on the need to improve the positional stability of the levitated samples, as well as the need to stabilize the temperature of the measurement coil. To demonstrate the validity of the technique, measurements have been performed on solid spheres of pure zirconium and low-carbon steel. In the case of zirconium, while absolute values of the resistivity were not determined, the temperature dependence of the resistivity was measured over the range of 640-1770 K and found to be in good agreement with literature data. In the case of low-carbon steel, the ferromagnetic-paramagnetic transition was clearly observable and, when combined with thermal data, appears to occur simultaneously with the solid-solid structural transition.

  2. Magnetic susceptibility measurements on ancient and modern potsherds using a fast, cheap and portable probe

    NASA Astrophysics Data System (ADS)

    Glover, P. W. J.

    2009-04-01

    It has been estimated that there exist over 100 million ancient potsherds in various collections worldwide, many of which have never been studied and for which the provenance is ambiguous or unknown. Indeed, many collections are extremely badly catalogued or completely mixed-up. We have been using a novel portable probe to measure the magnetic susceptibility and electrical conductivity of potsherds in the hope that this fast, cheap and portable measurement can provide data that will help to sort similar looking potsherds into sets in a manner which may help to define their provenance. The probe, which resembles a firearm, uses the Hall effect to make a non-destructive measurement on the potsherd. The probe is attached to an Dell Axim X51 PDA, which runs software that allows the measurement to be carried out and logged. Each measurement, which is made by pressing a button on the gun, takes only a few seconds. We have made measurements on three suites of ancient potsherds as well as a suite of modern potsherds that were created by using a garden centre and a hammer! In each case a set of 5 stacked measurements were taken on the inside and outside faces of the potsherd in two perpendicular directions. Potsherds which were either (i) so flat that the inside and outside could not be distinguished, (ii) so curved (radius of curvature less than 5 cm) that the probe tip could not approach the surface sufficiently closely, or (iii) smaller than the probe tip, were excluded from the suite of measurements. Each suite contained over 50 measureable potsherds. All measurements were completed within one day. In this pilot study we found that (1) each suite was represented by a normal distribution of magnestic susceptibility values, (2) the four different suites could be distinguished statistically on the basis of their magnetic susceptibilty measurements, but (3) the distinction was not sufficiently powerful to separate all potsherds (i.e., there was a significant overlap of the

  3. Studies on the activation energy from the ac conductivity measurements of rubber ferrite composites containing manganese zinc ferrite

    NASA Astrophysics Data System (ADS)

    Hashim, Mohd.; Alimuddin; Kumar, Shalendra; Shirsath, Sagar E.; Mohammed, E. M.; Chung, Hanshik; Kumar, Ravi

    2012-11-01

    Manganese zinc ferrites (MZF) have resistivities between 0.01 and 10 Ω m. Making composite materials of ferrites with either natural rubber or plastics will modify the electrical properties of ferrites. The moldability and flexibility of these composites find wide use in industrial and other scientific applications. Mixed ferrites belonging to the series Mn(1-x)ZnxFe2O4 were synthesized for different ‘x’ values in steps of 0.2, and incorporated in natural rubber matrix (RFC). From the dielectric measurements of the ceramic manganese zinc ferrite and rubber ferrite composites, ac conductivity and activation energy were evaluated. A program was developed with the aid of the LabVIEW package to automate the measurements. The ac conductivity of RFC was then correlated with that of the magnetic filler and matrix by a mixture equation which helps to tailor properties of these composites.

  4. Noncontact technique for measuring the electrical resistivity and magnetic susceptibility of electrostatically levitated melts

    NASA Astrophysics Data System (ADS)

    Rustan, G. E.; Spyrison, N. S.; Kreyssig, A.; Prozorov, R.; Goldman, A. I.

    2012-02-01

    Over the last two decades the popularity of levitation methods for studying equilibrium and supercooled melts has increased steadily. Measurements of density, viscosity, surface tension, and atomic structure have become well established. In contrast, measurements of electrical resistivity and magnetic susceptibility of levitated melts have been very limited. To fill this void, we have combined the tunnel diode oscillator (TDO) technique with electrostatic levitation (ESL) to perform inductively coupled measurements on levitated melts. A description of the basic operating principles of the TDO and ESL will be given, as well as a description of the implementation and performance characteristics of this technique. Preliminary measurements of electrical resistivity in the solid and liquid state will be presented for samples of Zr, Si, and Ge, as well as the measurements of ferromagnetic transitions in Fe and Co based alloys.

  5. Incorporating residential AC load control into ancillary service markets: Measurement and settlement

    SciTech Connect

    Bode, Josh L.; Sullivan, Michael J.; Berghman, Dries; Eto, Joseph H.

    2013-05-01

    Many pre-existing air conditioner load control programs can provide valuable operational flexibility but have not been incorporated into electricity ancillary service markets or grid operations. Multiple demonstrations have shown that residential air conditioner (AC) response can deliver resources quickly and can provide contingency reserves. A key policy hurdle to be overcome before AC load control can be fully incorporated into markets is how to balance the accuracy, cost, and complexity of methods available for the settlement of load curtailment. Overcoming this hurdle requires a means for assessing the accuracy of shorter-term AC load control demand reduction estimation approaches in an unbiased manner. This paper applies such a method to compare the accuracy of approaches varying in cost and complexity ? including regression analysis, load matching and control group approaches ? using feeder data, household data and AC end-use data. We recommend a practical approach for settlement, relying on an annually updated set of tables, with pre-calculated reduction estimates. These tables allow users to look up the demand reduction per device based on daily maximum temperature, geographic region and hour of day, simplifying settlement and providing a solution to the policy problem presented in this paper.

  6. A Torque Balance Measurement of Anisotropy of the Magnetic Susceptibility in White Matter

    PubMed Central

    van Gelderen, Peter; Mandelkow, Hendrik; de Zwart, Jacco A.; Duyn, Jeff H.

    2014-01-01

    Purpose Recent MRI studies have suggested that the magnetic susceptibility of white matter (WM) in the human brain is anisotropic, providing a new contrast mechanism for the visualization of fiber bundles and allowing the extraction of cellular compartment-specific information. This study provides an independent confirmation and quantification of this anisotropy. Methods Anisotropic magnetic susceptibility results in a torque exerted on WM when placed in a uniform magnetic field, tending to align the WM fibers with the field. To quantify the effect, excised spinal cord samples were placed in a torque balance inside the magnet of a 7 T MRI system and the magnetic torque was measured as function of orientation. Results All tissue samples (n=5) showed orienting effects, confirming the presence of anisotropic susceptibility. Analysis of the magnetic torque resulted in reproducible values for the WM volume anisotropy that ranged from 13.6 to 19.2 ppb. Conclusion The independently determined anisotropy values confirm estimates inferred from MRI experiments and validate the use of anisotropy to extract novel information about brain fiber structure and myelination. PMID:25399830

  7. Measurement of magnetic susceptibility in pulsed magnetic fields using a proximity detector oscillator.

    PubMed

    Ghannadzadeh, S; Coak, M; Franke, I; Goddard, P A; Singleton, J; Manson, J L

    2011-11-01

    We present a novel susceptometer with a particularly small spatial footprint and no moving parts. The susceptometer is suitable for use in systems with limited space where magnetic measurements may not have been previously possible, such as in pressure cells and rotators, as well as in extremely high pulsed fields. The susceptometer is based on the proximity detector oscillator, which has a broad dynamic resonant frequency range and has so far been used predominantly for transport measurements. We show that for insulating samples, the resonance frequency behavior as a function of field consists of a magnetoresistive and an inductive component, originating, respectively, from the sensor coil and the sample. The response of the coil is modeled, and upon subtraction of the magnetoresistive component the dynamic magnetic susceptibility and magnetization can be extracted. We successfully measure the magnetization of the organic molecular magnets Cu(H(2)O)(5)(VOF(4))(H(2)O) and [Cu(HF(2))(pyz)(2)]BF(4) in pulsed magnetic fields and by comparing the results to that from a traditional extraction susceptometer confirm that the new system can be used to measure and observe magnetic susceptibilities and phase transitions.

  8. AC losses in high pressure synthesized MgB2 bulk rings measured by a transformer method

    NASA Astrophysics Data System (ADS)

    Meerovich, V.; Sokolovsky, V.; Prikhna, T.; Gawalek, W.; Habisreuther, T.

    2013-03-01

    Recently developed manufacturing technologies use high pressure and various doping additions to prepare bulk MgB2-based materials with a high critical current density measured by the magnetization method. We use a contactless transformer method, which is based on studying the superconductor response to an induced transport current, to measure AC losses in bulk MgB2 rings synthesized under high pressure. The obtained dependence of the losses on the primary current (applied magnetic field) is fitted by a power law with an exponent of ˜2.1 instead of the cubic dependence predicted by Bean’s model and power law electric field-current density (E-J) characteristics with a large exponent. An unusually strong dependence of the AC losses on the frequency is also observed. It is shown that the E-J characteristic of bulk MgB2 is well fitted by the dependence used in the extended critical state model based on account of the viscous vortex motion in the flux flow regime. Numerical simulation using this E-J characteristic gives current and frequency AC loss dependences that agree well with the experimental results.

  9. Self-assembled magnetic bead biosensor for measuring bacterial growth and antimicrobial susceptibility testing.

    PubMed

    Kinnunen, Paivo; McNaughton, Brandon H; Albertson, Theodore; Sinn, Irene; Mofakham, Sima; Elbez, Remy; Newton, Duane W; Hunt, Alan; Kopelman, Raoul

    2012-08-20

    Bacterial antibiotic resistance is one of the major concerns of modern healthcare worldwide, and the development of rapid, growth-based, antimicrobial susceptibility tests is key for addressing it. The cover image shows a self-assembled asynchronous magnetic bead rotation (AMBR) biosensor developed for rapid detection of bacterial growth. Using the biosensors, the minimum inhibitory concentration of a clinical E. coli isolate can be measured within two hours, where currently tests take 6-24 hours. A 16-well prototype is also constructed for simple and robust observation of the self-assembled AMBR biosensors.

  10. Magnetic susceptibility measurements as proxy method to monitor soil pollution: development of experimental protocols for field surveys.

    PubMed

    D'Emilio, Mariagrazia; Chianese, Domenico; Coppola, Rosa; Macchiato, Maria; Ragosta, Maria

    2007-02-01

    In the framework of the development of new methods for measuring and monitoring soil pollution, this paper deals with the use of magnetic methodologies to monitor the heavy metals presence in soils. In particular it shows a procedure for collecting magnetic susceptibility measurements in order to interpret them as proxy variable for monitoring heavy metals in soils. Magnetic measurements are carried out using a magnetic susceptibility meter with two different probes for in situ field surveys. The experimental procedure is divided in two parts. In the first part we carry out laboratory tests aimed to evaluate, for both the probes, the effective investigation depth for soil, the measurement reproducibility under different conditions, and the influence of water content. We complete this part comparing in situ measurements obtained by means of two probes with different characteristics. In the second part we carry out tests to evaluate the relationships between heavy metal levels and magnetic susceptibility values of soil samples. We investigate the variability of the magnetic susceptibility measurements contaminating different soil samples with well known concentration of heavy metals. Moreover we study the correlation between magnetic susceptibility values and metal concentrations, determined by means of AAS, in soil samples collected during a field survey. Results suggest that a careful check of the experimental procedure play a crucial role for using magnetic susceptibility measurements for heavy metals in situ monitoring. This is very helpful both for improving the quality of data and for making simpler data interpretation.

  11. New measurement of exotic decay of 225Ac by 14C emission

    NASA Astrophysics Data System (ADS)

    Guglielmetti, A.; Bonetti, R.; Ardisson, G.; Barci, V.; Giles, T.; Hussonnois, M.; Le Du, J. F.; Le Naour, C.; Mikheev, V. L.; Pasinetti, A. L.; Ravn, H. L.; Tretyakova, S. P.; Trubert, D.

    The branching ratio of 225Ac decay by emission of 14C was remeasured under improved experimental conditions by using a radioactive source produced at the ISOLDE mass-separator at CERN and a nuclear track detector technique. The result, B = λ14C/λα = (4.5+/-1.4)10-12, is consistent with the anomalously high value obtained in the 1993 experiment, thus confirming the importance of nuclear-structure effects in this exotic decay.

  12. Petrophysical Characterization of Stony Meteorites Using Low Field Magnetic Susceptibility: Initial Results From Anisotropy Measurements

    NASA Astrophysics Data System (ADS)

    Smith, D. L.; Ernst, R. E.; Herd, R. K.; Claire, S.

    2004-05-01

    Low field magnetic susceptibility represents a fast, systematic and non-destructive technique of meteorite classification [1-4]. We previously reported measurements of bulk susceptibility, and its frequency dependence, along with a `proxy' measure of anisotropy, on 204 specimens from 108 different meteorites in the National Meteorite Collection of Canada [5,6]. Measurements were performed on a Sapphire Instruments Model 2B. Bulk susceptibility values followed expected trends, governed by metal content, with values increasing from LL, to L, to H, to E chondrites. Frequency dependence (19000 vs 825 Hz) was greatest in H and C chondrites. Aubrites (AUB) and Howardites (HOW) had the lowest. Anisotropy of magnetic susceptibility (AMS) was measured using a `proxy' approach: the mean value determined from a series of random sample orientations was compared with repeated measurements in one orientation. AUB, E chondrites and Martian SNCs had the largest inferred anisotropies, while LL and C chondrites had the lowest. Here we report initial results from a follow-up study. Quantitative measurements of the AMS were made on 67 stony meteorite specimens. AMS measurements [3,5,6,7,8,9] can provide information on the physical fabric of the meteorite, and may relate to its deformational history. Samples measured show significant degrees of anisotropy ranging from 1-50 % for an individual specimen (in parentheses is the number of specimens used in the class mean): AUB (5), Acapulcoites (1) and E chondrites (10) display the largest degrees of anisotropy, 40±11 (1 standard deviation), 34, and 24±10, respectively. These classes are followed by Diogenite (1) 20, H (13) 14±7 and L (10) 13±6 chondrites, Brachinite (1) 11, Ureilite (2) 8, Eucrite (4) 7±4, C chondrites (14) 6±3, and Rumurutiite (1) 4. These results match a similar trend based on the `proxy' method [5,6]: AUB and E chondrites were found to have the highest inferred anisotropies followed by tightly grouped H and L

  13. Anisotropy of diamagnetic susceptibility in Thassos marble: A comparison between measured and modeled data

    NASA Astrophysics Data System (ADS)

    de Wall, Helga; Bestmann, Michel; Ullemeyer, Klaus

    2000-11-01

    A study of shear zones within the calcite marble complex of the island of Thassos (Greece) shows that the low field anisotropy of magnetic susceptibility (AMS)-technique can be successfully applied to diamagnetic rocks for characterizing rock fabrics. The strain path involves both an early pure shear stage and a simple shear overprint that is documented by a transition from triaxial (neutral) to uniaxial (prolate) shapes of AMS ellipsoids. The maximum susceptibility is oriented perpendicular to the rock foliation, reflecting the preferred orientation of calcite c-axes in the protolith as well as in the mylonites. For three samples that represent different types of calcite fabrics, the AMS was recalculated from neutron and electron backscatter diffraction textural data. A comparison of the measured and modeled data shows a good coincidence for the orientation of the principal AMS axes and for the recalculated anisotropy data. Both measured and modeled data sets reflect the change from neutral to distinct prolate ellipsoids during progressive deformation.

  14. Investigation of the Neel Model of Thermal Activation in Heterogeneous Cobalt-Silver Alloy Films Through the Use of Dynamic Susceptibility Measurements

    NASA Astrophysics Data System (ADS)

    Slade, Steven Barclay

    Co-Ag heterogeneous alloys films having 5 at% Co are produced by sputtering and annealed after deposition to relieve stress and promote particle growth. X-ray diffraction suggests the as-deposited state consists of a single fcc alloy phase, with local density fluctuations resulting from the immiscible nature of Co and Ag leading to the formation of Co-rich and Ag-rich regions. Annealing is seen to drive progressive separation and growth of the Ag-rich and Co-rich areas. Characterizations of magnetic properties indicate the Co precipitates are ferromagnetically ordered and have a uniaxial anisotropy. A Curie-Weiss analysis of the inverse initial dc susceptibility indicates the as-deposited film has net antiferromagnetic interparticle magnetic interactions, while the annealed sample has non-interacting particles. Fitting the magnetization curves to a Langevin function with a lognormal volume distribution indicates the films have a narrow particle size distribution. The thermal activation behavior of the annealed sample is investigated through the use of dynamic susceptibility measurements made with a high sensitivity ac susceptometer and a SQUID magnetometer, which span 8 decades in frequency. The Neel model of thermal activation is first applied to the in-phase susceptibility data following a generally-accepted conventional analysis taken from the spin glass literature. Trends in the data are consistent with the Neel model, but values for the prefactor and the most probable energy barrier to reversal from this analysis are unphysical. A new method for applying the Neel model is presented, and allows, for the first time, correct application of this model to dynamic susceptibility data from a distributed system. This analysis of the dynamic susceptibility data yields physically meaningful results, provides a direct measure of the distribution of energy barriers, and derives a scaling relationship allowing data at different frequencies to be scaled onto a universal

  15. Calorimetric AC loss measurement of MgB2 superconducting tape in an alternating transport current and direct magnetic field

    NASA Astrophysics Data System (ADS)

    See, K. W.; Xu, X.; Horvat, J.; Cook, C. D.; Dou, S. X.

    2012-11-01

    Applications of MgB2 superconductors in electrical engineering have been widely reported, and various studies have been made to define their alternating current (AC) losses. However, studies on the transport losses with an applied transverse DC magnetic field have not been conducted, even though this is one of the favored conditions in applications of practical MgB2 tapes. Methods and techniques used to characterize and measure these losses have so far been grouped into ‘electrical’ and ‘calorimetric’ approaches with external conditions set to resemble the application conditions. In this paper, we present a new approach to mounting the sample and employ the calorimetric method to accurately determine the losses in the concurrent application of AC transport current and DC magnetic fields that are likely to be experienced in practical devices such as generators and motors. This technique provides great simplification compared to the pickup coil and lock-in amplifier methods and is applied to a long length (˜10 cm) superconducting tape. The AC loss data at 20 and 30 K will be presented in an applied transport current of 50 Hz under external DC magnetic fields. The results are found to be higher than the theoretical predictions because of the metallic fraction of the tape that contributes quite significantly to the total losses. The data, however, will allow minimization of losses in practical MgB2 coils and will be used in the verification of numerical coil models.

  16. Developing passive MEMS DC/AC current sensor applicable to two-wire appliances with high measurement accuracy

    NASA Astrophysics Data System (ADS)

    Wang, Dong F.; Li, Xiaodong; Xian, Weikang; Liu, Huan; Liu, Xin

    2016-10-01

    A passive MEMS DC/AC current sensor with high measurement accuracy, accomplished by the methodology combining both the "stress-equilibrium" solution and the "position-free" solution, was proposed for measuring electricity consumption of household equipment and Information and Communication Technology devices. For the "stress-equilibrium" solution, slots between two adjacent piezoelectric plates are implemented to minimize the distribution difference of the uneven stress close to the fixed end. The measurement error caused by the uneven stress distribution is decreased from 9% to 4% for ten-piezoelectric-plates and from 8% to 0.5% for three-piezoelectric-plates, respectively. For the "position-free" consideration, an array comprised of four piezoelectric cantilevers is proposed to eliminate the positional error resulted by the uneven magnetic field distribution generated by the test object of electric currents. And the solution is proofed to be an effective method to eliminate the positional error by theoretical and simulation analysis. In light of the above preliminary results, the passive MEMS DC/AC current sensor is believed to be useful to achieve high measurement accuracy via integrating the "stress-equilibrium" and the "position-free" designs. The newly proposed current sensor with high measurement accuracy is applicable to two-wire appliance cord without using any cord separator like that used in Hall-effect based sensor.

  17. Low temperature radio-frequency transverse susceptibility measurements using a CMOS oscillator circuit

    NASA Astrophysics Data System (ADS)

    Figueroa, A. I.; Bartolomé, J.; García del Pozo, J. M.; Arauzo, A.; Guerrero, E.; Téllez, P.; Bartolomé, F.; García, L. M.

    2012-08-01

    A transverse susceptibility (TS) measurement system based on a simple inverter CMOS cell oscillator cross-coupled to a LC tank is presented. The system has been implemented to operate at a Quantum Design Physical Properties Measurement System (PPMS). We introduce several improvements with respect to similar currently operating TS measurement equipments. The electronics have been redesigned to use CMOS transistors as active devices, which simplifies the circuit design and enlarge the tuning range, thus making the proposed electronic block more feasible, predictable, and precise. Additionally, we propose a newly designed sample holder, which facilitates the procedure to change a sample and improves reproducibility of the circuit. Our design minimizes the thermal leak of the measuring probe by one order of magnitude, allowing to measure from 1.8 K in standard PPMS systems, thanks to the use of a low temperature beryllium-copper coaxial cable instead of the conventional RG402 Cu coaxial cable employed in the insert for the PPMS in similar systems. The data acquisition method is also simplified, so that the measuring sequences are implemented directly in the PPMS controller computer by programming them in the Quantum Design MultiVu software that controls the PPMS. We present the test measurements performed on the system without sample to study the background signal and stability of the circuit. Measurements on a Gd2O3 calibrating sample yield to the estimation of the system sensitivity, which is found to be on the order of 10-6 emu. Finally, measurements on a TmCo2 Laves phase sample with a ferrimagnetic transition temperature around 4 K are described, demonstrating that the developed system is well suited to explore interesting magnetic phenomena at this temperature scale.

  18. Global Lithospheric Apparent Susceptibility Distribution Converted from Geomagnetic Models by CHAMP and Swarm Satellite Magnetic Measurements

    NASA Astrophysics Data System (ADS)

    Du, Jinsong; Chen, Chao; Xiong, Xiong; Li, Yongdong; Liang, Qing

    2016-04-01

    Recently, because of continually accumulated magnetic measurements by CHAMP satellite and Swarm constellation of three satellites and well developed methodologies and techniques of data processing and geomagnetic field modeling etc., global lithospheric magnetic anomaly field models become more and more reliable. This makes the quantitative interpretation of lithospheric magnetic anomaly field possible for having an insight into large-scale magnetic structures in the crust and uppermost mantle. Many different approaches have been utilized to understand the magnetized sources, such as forward, inversion, statistics, correlation analysis, Euler deconvolution, signal transformations etc. Among all quantitative interpretation methods, the directly converting a magnetic anomaly map into a magnetic susceptibility anomaly map proposed by Arkani-Hamed & Strangway (1985) is, we think, the most fast quantitative interpretation tool for global studies. We just call this method AS85 hereinafter for short. Although Gubbins et al. (2011) provided a formula to directly calculate the apparent magnetic vector distribution, the AS85 method introduced constraints of magnetized direction and thus corresponding results are expected to be more robust especially in world-wide continents. Therefore, in this study, we first improved the AS85 method further considering non-axial dipolar inducing field using formulae by Nolte & Siebert (1987), initial model or priori information for starting coefficients in the apparent susceptibility conversion, hidden longest-wavelength components of lithospheric magnetic field and field contaminations from global oceanic remanent magnetization. Then, we used the vertically integrated susceptibility model by Hemant & Maus (2005) and vertically integrated remanent magnetization model by Masterton et al. (2013) to test the validity of our improved method. Subsequently, we applied the conversion method to geomagnetic field models by CHAMP and Swarm satellite

  19. Quantification of magnetic nanoparticles with broadband measurements of magnetic susceptibility in the frequency domain

    NASA Astrophysics Data System (ADS)

    Kodama, Kazuto; An, Zhisheng; Chang, Hong; Qiang, Xiaoke

    2015-04-01

    Measurement of low-field magnetic susceptibility over a wide band of frequencies spanning four orders of magnitude is a useful method for the assessment of the grain size distribution of ultrafine magnetic particles smaller than the SP/SSD boundary. This method has been applied to a loess/paleosol sequence at Luochuan in the Chinese Loess Plateau. The studied succession consists of sequences from the latest paleosol unit to the upper part of the loess unit, spanning the last glacial-interglacial cycle. Reconstructed grain size distributions (GSDs) consist of volume fractions on the order of 10-24 m3, and the mean GSDs are modal but with distinctive skewness among the loess, the weakly developed paleosol (weak paleosol), and the mature paleosol. This indicates that the mean volume of SP particles in this sequence tends to increase during the transition from the loess to the paleosol. An index, defined as the difference between χ130 at the lowest (130 Hz) and χ500k at the highest (500 kHz) frequencies normalized to χ130, is judged to be a more suitable index than previous frequency dependence parameters for the concentration of SP particles. This index has a strong correlation with χ130, showing a continuous 'growth curve' with the rate of increase being highest for the loess, moderate for the weak paleosol, and saturated for the paleosol. The characteristic curve suggests that smaller SP particles are preferentially formed in the earlier stage of pedogenesis rather than the later phase when even larger particles are formed in the mature paleosol. These results demonstrate that the broad-band-frequency susceptibility measurement will be useful for the quantitative assessment of magnetic nanoparticles in soils and sediments. Additionally, we point out that the measurement in the frequency domain generally requires time and may not be most suitable to routine measurements. We thus propose an alternative manner, the measurement in the time domain that can be

  20. RNA interference knockdown of aminopeptidase N genes decrease the susceptibility of Chilo suppressalis larvae to Cry1Ab/Cry1Ac and Cry1Ca-expressing transgenic rice.

    PubMed

    Qiu, Lin; Fan, Jinxing; Zhang, Boyao; Liu, Lang; Wang, Xiaoping; Lei, Chaoliang; Lin, Yongjun; Ma, Weihua

    2017-03-06

    Transgenic rice expressing Bacillus thuringiensis (Bt) Cry toxins are resistant to lepidopteran pests, such as Chilo suppressalis, a major insect pest of rice in Asia. Understanding how these toxins interact with their hosts is crucial to understanding their insecticidal action. In this study, knockdown of two aminopeptidase N genes (APN1 and APN2) by RNA interference resulted in decreased susceptibility of C. suppressalis larvae to the Bt rice varieties TT51 (Cry1Ab and Cry1Ac fusion genes) and T1C-19 (Cry1Ca), but not T2A-1 (Cry2Aa). This suggests that APN1 and APN2 are receptors for Cry1A and Cry1C toxins in C. suppressalis.

  1. Precipitation susceptibility in marine stratocumulus and shallow cumulus from airborne measurements

    NASA Astrophysics Data System (ADS)

    Jung, Eunsil; Albrecht, Bruce A.; Sorooshian, Armin; Zuidema, Paquita; Jonsson, Haflidi H.

    2016-09-01

    Precipitation tends to decrease as aerosol concentration increases in warm marine boundary layer clouds at fixed liquid water path (LWP). The quantitative nature of this relationship is captured using the precipitation susceptibility (So) metric. Previously published works disagree on the qualitative behavior of So in marine low clouds: So decreases monotonically with increasing LWP or cloud depth (H) in stratocumulus clouds (Sc), while it increases and then decreases in shallow cumulus clouds (Cu). This study uses airborne measurements from four field campaigns on Cu and Sc with similar instrument packages and flight maneuvers to examine if and why So behavior varies as a function of cloud type. The findings show that So increases with H and then decreases in both Sc and Cu. Possible reasons for why these results differ from those in previous studies of Sc are discussed.

  2. An in situ antimicrobial susceptibility testing method based on in vivo measurements of chlorophyll α fluorescence.

    PubMed

    Heliopoulos, Nikolaos S; Galeou, Angeliki; Papageorgiou, Sergios K; Favvas, Evangelos P; Katsaros, Fotios K; Stamatakis, Kostas

    2015-05-01

    Up to now antimicrobial susceptibility testing (AST) methods are indirect and generally involve the manual counting of bacterial colonies following the extraction of microorganisms from the surface under study and their inoculation in a separate procedure. In this work, an in situ, direct and instrumental method for the evaluation and assessment of antibacterial properties of materials and surfaces is proposed. Instead of indirectly determining antibacterial activity using the typical gram(-) test organisms with the subsequent manual colony count or inhibition zone measurement, the proposed procedure, employs photosynthetic gram(-) cyanobacteria deposited directly onto the surface under study and assesses cell proliferation and viability by a quick, accurate and reproducible instrumental chlorophyll fluorescence spectrophotometric technique. In contrast with existing methods of determination of antibacterial properties, it produces high resolution and quantitative results and is so versatile that it could be used to evaluate the antibacterial properties of any compound (organic, inorganic, natural or man-made) under any experimental conditions, depending on the targeted application.

  3. Novel multijunction thermal converter in planar technique for AC current, voltage, power and optical radiation measurement

    NASA Astrophysics Data System (ADS)

    Klonz, M.; Weimann, T.

    1990-05-01

    A new planar thin film design of multijunction thermocouples on a silicon chip containing a window with a SiO2-membrane for low heat conductance underneath of the thermocouples is described. It is used as the sensor for the temperature difference in a multijunction thermal converter for ac-dc transfer of electrical quantities like voltage, current and power via Joule heat in a thin film resistor. By coating the heater with an optically absorbing layer it is used as a highly sensitive radiometer transferring absorbed energy to Joule heat in the resistor. The design can easily be optimized for all different frequency applications. It offers the possibility of the mass production of transfer standards at highest level of accuracy.

  4. Study of AC/RF properties of SRF ingot niobium

    SciTech Connect

    Dhakal, Pashupati; Tsindlekht, Menachem I; Genkin, Valery M; Ciovati, Gianluigi; Myneni, Ganapati Rao

    2013-09-01

    In an attempt to correlate the performance of superconducting radiofrequency cavities made of niobium with the superconducting properties, we present the results of the magnetization and ac susceptibility of the niobium used in the superconducting radiofrequency cavity fabrication. The samples were subjected to buffer chemical polishing (BCP) surface and high temperature heat treatments, typically applied to the cavities fabrications. The analysis of the results show the different surface and bulk ac conductivity for the samples subjected to BCP and heat treatment. Furthermore, the RF surface impedance is measured on the sample using a TE011 microwave cavity for a comparison to the low frequency measurements.

  5. Electrical Effect in Silver-Point Realization Due to Cell Structure and Bias Voltage Based on Resistance Measurement Using AC and DC Bridges

    NASA Astrophysics Data System (ADS)

    Widiatmo, J. V.; Harada, K.; Yamazawa, K.; Tamba, J.; Arai, M.

    2015-08-01

    Electrical effects related to insulating leakage represent one of the major factors contributing to uncertainties in measurements using high-temperature standard platinum resistance thermometers (HTSPRTs), especially during the realization of the silver freezing point (). This work is focused on the evaluation of the differences in resistance measurements observed when using AC resistance bridges and DC resistance bridges, hereafter, termed the AC-DC differences, as the result of various electrical effects. The magnitude of the AC-DC difference in several silver-point cells is demonstrated with several HTSPRTs. The effect of the cell structure on the AC-DC difference is evaluated by exchanging some components, part by part, within a silver-point cell. Then, the effect of the bias voltage applied to the heat pipe within the silver-point furnace is evaluated. Through the analysis of the experimental results and comparison with the reports in the literature, the importance of evaluating the AC-DC difference as a means to characterize the underlying electrical effects is discussed, considering that applying a negative bias condition to the furnace with respect to the high-temperature SPRT can minimize the AC-DC difference. Concluding recommendations are proposed on the components used in silver-point cells and the application of a bias voltage to the measurement circuit to minimize the effects of the electrical leakage.

  6. Modification of lung cancer susceptibility by green tea extract as measured by the comet assay.

    PubMed

    Zhang, Huifeng; Spitz, Margaret R; Tomlinson, Gail E; Schabath, Matthew B; Minna, John D; Wu, Xifeng

    2002-01-01

    Green tea is widely consumed throughout the world and is known to possess various beneficial properties that may affect carcinogen metabolism, free radical scavenging, or formation of DNA adducts. Therefore, it is plausible that green tea extract may modify BPDE-induced DNA damage. In this report, we utilized the comet assay to (1) evaluate BPDE-induced DNA damage as a potential marker of cancer susceptibility and (2) assess the ability of green tea to modify BPDE-induced DNA damage. DNA damage in individual comet cells was quantified by (1) visually measuring the proportion of cells exhibiting migration versus those without and (2) the length of damaged DNA migration (comet tail). We detected a dose-response between BDPE concentration and mean comet tail length in EBV-immortalized lymphoblastiod (lymphoid) cell lines. As the concentration of BPDE increased from 0.5 to 3 microM, the length of the mean comet tail length increased proportionally in the 3590P (derived from a healthy subject) and 3640P (derived from a patient with head and neck cancer) cell lines. In separate experiments using lymphoid cells from 21 lung cancer cases and 12 healthy subjects, the mean comet tail length was significantly higher in the lung cancer cases (80.19 +/- 15.55) versus the healthy subjects (59.94 +/- 14.23) (P < 0.01). Similar findings were observed when analyzing the mean percentage of comet induced cells (84.57 +/- 8.85 and 69.04 +/- 12.50, respectively) (P < 0.01). When green tea extract was added in conjunction with BPDE, there was a notable reduction of the mean comet tail length (13.29 +/- 0.97) as compared to BPDE treatment alone (80.19 +/- 15.55) (P < 0.01) in lung cancer cases. There were no statistical differences between the baseline (no treatments) (12.74 +/- 0.63) and the green tea extract treatment (13.06 +/- 0.97) (P = 0.21). These data suggest the modification of lung cancer susceptibility by the green tea extract. Similar results were observed for the percentage

  7. Optical, electrical and ac conductivity measurements of nonlinear optical Dimethylaminomethylphthalimide doped with cadmium chloride single crystal for nano applications

    NASA Astrophysics Data System (ADS)

    Subramani, K.; Joseph, P. S.; Shankar, G.

    2013-07-01

    Single crystals of Dimethylaminomethylphthalimide cadmium chloride (DAMPCC) were grown by a slow evaporation technique. The unit cell parameters and crystal structure were measured by the powder X-ray diffraction analysis. The modes of vibrations of different molecular groups present in the DAMPCC crystal have been identified by FTIR spectral analysis. The UV-vis-NIR spectral analysis is used to study the optical behaviors like absorption and transmission properties of the crystal. The diffuse reflectance spectrum in absorption studies is calculated. The optical band gap of the DAMPCC crystal is calculated to be cut off wavelength 360 nm at photon energy 4.772 eV. The optical conductivity, electrical conductivity and ac conductivity are also calculated. Finally the nonlinear optics (NLO) property of DAMPCC crystal was confirmed by second harmonic generation (SHG) test using the Nd:YAG laser of fundamental wavelength 1064 nm.

  8. Evaluation of the electrode performance for PAFC by using acid absorption, acceleration and ac-impedance measurement

    SciTech Connect

    Kim, Chang-Soo; Song, Rak-Hyun; Choi, Byung-Woo

    1996-12-31

    In PAFC, the degradation on cathode electrode caused by carbon corrosion, platinum dissolution and growth is especially severe. An acceleration test is a good technique for evaluating the degradation of electrode performance, because it does not need long time. Coleman et al used thermal cycling and on-off cycling as an acceleration test. Song et al showed that hydrogen shortage decreased the electrode performance more rapidly than that of air shortage in gas shortage test. Honji et al reported that the rate of coarsening of Pt particle is rapid in open circuit potential and this is one of major causes on the performance degradation of electrode. The cathode performance has been studied by using acid absorption, acceleration and ac-impedance measurements as functions of the polytetrafluoroethylene (PTFE) contents and sintering temperatures of the electrode.

  9. The Effect of Inhomogeneous Sample Susceptibility on Measured Diffusion Anisotropy Using NMR Imaging

    NASA Astrophysics Data System (ADS)

    Trudeau, J. D.; Dixon, W. T.; Hawkins, J.

    1995-07-01

    Water diffusion measurements in white matter of freshly excised pig spinal cord and in parenchyma of fresh celery (excluding the fibers along the edge of the stalk) were performed using NMR at 200 MHz. In white matter of pig spinal cord, the measured diffusion coefficient is anisotropic and independent of sample orientation with respect to the magnetic field, In celery parenchyma, diffusion is isotropic and independent of orientation in the magnetic field when using a diffusion sequence that gives results independent of self-induced magnetic-held gradients. However, when the standard diffusion pulse sequence that gives results dependent upon self-induced magnetic-field gradients is used, diffusion in celery appears isotropic when the stalk is oriented parallel to the magnetic field but anisotropic when oriented perpendicular. Susceptibility variations leading to anisotropic self-induced magnetic-field gradients approximately 3 kHz/cm in magnitude when the celery is oriented perpendicular to the magnetic field can explain this apparent anisotropic diffusion. A study of the apparent diffusion coefficient (ADC) in celery as a function of diffusion times ranging from 8 to 22 ms indicates that the motion is at most only slightly restricted. Therefore, although the effect is not seen in all types of samples, one must be aware that self-induced gradients may affect the ADC and may cause isotropic diffusion to appear anisotropic. In addition, NMR experiments that change diffusion-sensitizing gradient timings to study restricted diffusion change the effects of the self-induced gradients as well as the effect of barriers on the ADC, complicating interpretation.

  10. Aging dynamics in the polymer glass of poly(2-chlorostyrene): Dielectric susceptibility and volume

    NASA Astrophysics Data System (ADS)

    Fukao, Koji; Tahara, Daisuke

    2009-11-01

    Aging dynamics was investigated in the glassy states of poly(2-chlorostyrene) by measuring the complex electrical capacitance during aging below the glass transition temperature. The variations with time and temperature of the ac dielectric susceptibility and volume could be determined by simply measuring the variation in the complex electrical capacitance. Isothermal aging at a given temperature for several hours after an intermittent stop in constant-rate cooling is stored in the deviations of both the real and imaginary parts of the complex ac dielectric susceptibility and volume. During cooling after isothermal aging, the deviation of the ac dielectric susceptibility from the reference value decreases and almost vanishes at room temperature. By contrast, the deviation in volume induced during isothermal aging remains almost constant during cooling. The simultaneous measurement of ac dielectric susceptibility and volume clearly revealed that the ac dielectric susceptibility exhibits a full rejuvenation effect, whereas the volume does not show any rejuvenation effects. We discuss a plausible model that can reproduce the present experimental results.

  11. Calculation of susceptibility through multiple orientation sampling (COSMOS): a method for conditioning the inverse problem from measured magnetic field map to susceptibility source image in MRI.

    PubMed

    Liu, Tian; Spincemaille, Pascal; de Rochefort, Ludovic; Kressler, Bryan; Wang, Yi

    2009-01-01

    Magnetic susceptibility differs among tissues based on their contents of iron, calcium, contrast agent, and other molecular compositions. Susceptibility modifies the magnetic field detected in the MR signal phase. The determination of an arbitrary susceptibility distribution from the induced field shifts is a challenging, ill-posed inverse problem. A method called "calculation of susceptibility through multiple orientation sampling" (COSMOS) is proposed to stabilize this inverse problem. The field created by the susceptibility distribution is sampled at multiple orientations with respect to the polarization field, B(0), and the susceptibility map is reconstructed by weighted linear least squares to account for field noise and the signal void region. Numerical simulations and phantom and in vitro imaging validations demonstrated that COSMOS is a stable and precise approach to quantify a susceptibility distribution using MRI.

  12. Microfabricated AC impedance sensor

    DOEpatents

    Krulevitch, Peter; Ackler, Harold D.; Becker, Frederick; Boser, Bernhard E.; Eldredge, Adam B.; Fuller, Christopher K.; Gascoyne, Peter R. C.; Hamilton, Julie K.; Swierkowski, Stefan P.; Wang, Xiao-Bo

    2002-01-01

    A microfabricated instrument for detecting and identifying cells and other particles based on alternating current (AC) impedance measurements. The microfabricated AC impedance sensor includes two critical elements: 1) a microfluidic chip, preferably of glass substrates, having at least one microchannel therein and with electrodes patterned on both substrates, and 2) electrical circuits that connect to the electrodes on the microfluidic chip and detect signals associated with particles traveling down the microchannels. These circuits enable multiple AC impedance measurements of individual particles at high throughput rates with sufficient resolution to identify different particle and cell types as appropriate for environmental detection and clinical diagnostic applications.

  13. Improving the method of low-temperature anisotropy of magnetic susceptibility (LT-AMS) measurements in air

    NASA Astrophysics Data System (ADS)

    Issachar, R.; Levi, T.; Lyakhovsky, V.; Marco, S.; Weinberger, R.

    2016-07-01

    This study examines the limitations of the method of low-temperature anisotropy of magnetic susceptibility (LT-AMS) measurements in air and presents technical improvements that significantly reduce the instrumental drift and measurement errors. We analyzed the temperature profile of porous chalk core after cooling in liquid nitrogen and found that the average temperature of the sample during the LT-AMS measurement in air is higher than 77K and close to 92K. This analysis indicates that the susceptibility of the paramagnetic minerals are amplified by a factor ˜3.2 relative to that of room temperature AMS (RT-AMS). In addition, it was found that liquid nitrogen was absorbed in the samples during immersing and contributed diamagnetic component of ˜-9 × 10-6 SI to the total mean susceptibility. We showed that silicone sheet placed around and at the bottom of the measuring coil is an effective thermal protection, preventing instrument drift by the cold sample. In this way, the measuring errors of LT-AMS reduced to the level of RT-AMS, allowing accurate comparison with standard AMS measurements. We examined the applicability of the LT-AMS measurements on chalk samples that consist <5% (weight) of paramagnetic minerals and showed that it helps to efficiently enhance the paramagnetic fabric. The present study offers a practical approach, which can be applied to various types of rocks to better delineate the paramagnetic phase using conventional equipment.

  14. Quantitative susceptibility mapping (QSM) as a means to measure brain iron? A post mortem validation study.

    PubMed

    Langkammer, Christian; Schweser, Ferdinand; Krebs, Nikolaus; Deistung, Andreas; Goessler, Walter; Scheurer, Eva; Sommer, Karsten; Reishofer, Gernot; Yen, Kathrin; Fazekas, Franz; Ropele, Stefan; Reichenbach, Jürgen R

    2012-09-01

    Quantitative susceptibility mapping (QSM) is a novel technique which allows determining the bulk magnetic susceptibility distribution of tissue in vivo from gradient echo magnetic resonance phase images. It is commonly assumed that paramagnetic iron is the predominant source of susceptibility variations in gray matter as many studies have reported a reasonable correlation of magnetic susceptibility with brain iron concentrations in vivo. Instead of performing direct comparisons, however, all these studies used the putative iron concentrations reported in the hallmark study by Hallgren and Sourander (1958) for their analysis. Consequently, the extent to which QSM can serve to reliably assess brain iron levels is not yet fully clear. To provide such information we investigated the relation between bulk tissue magnetic susceptibility and brain iron concentration in unfixed (in situ) post mortem brains of 13 subjects using MRI and inductively coupled plasma mass spectrometry. A strong linear correlation between chemically determined iron concentration and bulk magnetic susceptibility was found in gray matter structures (r=0.84, p<0.001), whereas the correlation coefficient was much lower in white matter (r=0.27, p<0.001). The slope of the overall linear correlation was consistent with theoretical considerations of the magnetism of ferritin supporting that most of the iron in the brain is bound to ferritin proteins. In conclusion, iron is the dominant source of magnetic susceptibility in deep gray matter and can be assessed with QSM. In white matter regions the estimation of iron concentrations by QSM is less accurate and more complex because the counteracting contribution from diamagnetic myelinated neuronal fibers confounds the interpretation.

  15. Influence of the carbon substitution on the critical current density and AC losses in MgB2 single crystals

    NASA Astrophysics Data System (ADS)

    Ciszek, M.; Rogacki, K.; Oganisian, K.; Zhigadlo, N. D.; Karpinski, J.

    2010-12-01

    The DC magnetization and AC complex magnetic susceptibilities were measured for MgB2 single crystals, unsubstituted and carbon substituted with the composition of Mg(B0.94C0.05)2. The measurements were performed in AC and DC magnetic fields oriented parallel to the c-axis of the crystals. From the DC magnetization loops and the AC susceptibility measurements, critical current densities ( J c were derived as a function of temperature and the DC and AC magnetic fields. Results show that the substitution with carbon decreases J c ) at low magnetic fields, opposite to the well known effect of an increase of J c at higher fields. AC magnetic losses were derived from the AC susceptibility data as a function of amplitude and the DC bias magnetic field. The AC losses were determined for temperatures of 0.6 and 0.7 of the transition temperature T c , so close to the boiling points of LH2 and LNe, potential cooling media for magnesium diboride based composites. The results are analyzed and discussed in the context of the critical state model.

  16. Regionally progressive accumulation of iron in Parkinson's disease as measured by quantitative susceptibility mapping.

    PubMed

    Guan, Xiaojun; Xuan, Min; Gu, Quanquan; Huang, Peiyu; Liu, Chunlei; Wang, Nian; Xu, Xiaojun; Luo, Wei; Zhang, Minming

    2017-04-01

    The progression of Parkinson's disease (PD) seems to vary according to the disease stage, which greatly influences the management of PD patients. However, the underlying mechanism of progression in PD remains unclear. This study was designed to explore the progressive pattern of iron accumulation at different stages in PD patients. Sixty right-handed PD patients and 40 normal controls were recruited. According to the disease stage, 45 patients with Hoehn-Yahr stage ≤ 2.5 and 15 patients with Hoehn-Yahr stage ≥ 3 were grouped into early-stage PD (EPD) and late-stage PD (LPD) groups, respectively. The iron content in the cardinal subcortical nuclei covering the cerebrum, cerebellum and midbrain was measured using quantitative susceptibility mapping (QSM). The substantia nigra pars compacta (SNc) showed significantly increased QSM values in the EPD patients compared with the controls. In the LPD patients, while the SNc continued to show increased QSM values compared with the controls and EPD patients, the regions showing increased QSM values spread to include the substantia nigra pars reticulata (SNr), red nucleus (RN) and globus pallidus (GP). Our data also indicated that iron deposition was more significant in the GP internal segment (GPi) than in the GP external segment. No other regions showed significant changes in QSM values among the groups. Therefore, we were able to confirm a regionally progressive pattern of iron accumulation in the different stages of PD, indicating that iron deposition in the SNc is affected exclusively in the early stages of the disease, while the SNr, RN and GP, and particularly the GPi segment, become involved in advanced stages of the disease. This is a preliminary study providing objective evidence of the iron-related progression in PD. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Measurement of the second-order nonlinear susceptibility of collagen using polarization modulation and phase-sensitive detection

    NASA Astrophysics Data System (ADS)

    Stoller, Patrick C.; Kim, Beop-Min; Rubenchik, Alexander M.; Reiser, Karen M.; Da Silva, Luiz B.

    2001-05-01

    The measurement of the second order nonlinear susceptibility of collagen in various biological tissues has potential applications in the detection of structural changes which are related to different pathological conditions. We investigate second harmonic generation in a rat-tail tendon, a highly organized collagen structure consisting of parallel fibers. Using an electro-optic modulator and a quarter-wave plate, we modulate the linear polarization of an ultra-short pulse laser beam that is used to measure second harmonic generation in a confocal microscopy setup. Phase-sensitive detection of the generated signal, coupled with a simple model of the collagen protein structures, allows us to measure a parameter (gamma) related to nonlinear susceptibility and to determine the relative orientation of the structures. Our preliminary results indicate that it may be possible to use this parameter to characterize the structure.

  18. Measurement of the Second Order Non-linear Susceptibility of Collagen using Polarization Modulation and Phase-sensitive Detection

    SciTech Connect

    Stoller, P; Kim, B-M; Rubenchik, A M; Reiser, K M; Da Silva, L B

    2001-03-03

    The measurement of the second order nonlinear susceptibility of collagen in various biological tissues has potential applications in the detection of structural changes which are related to different pathological conditions. We investigate second harmonic generation in rat-tail tendon, a highly organized collagen structure consisting of parallel fibers. Using an electro-optic modulator and a quarter-wave plate, we modulate the linear polarization of an ultra-short pulse laser beam that is used to measure second harmonic generation (SHG) in a confocal microscopy setup. Phase-sensitive detection of the generated signal, coupled with a simple model of the collagen protein structures, allows us to measure a parameter {gamma} related to nonlinear susceptibility and to determine the relative orientation of the structures. Our preliminary results indicate that it may be possible to use this parameter to characterize the structure.

  19. AC susceptibility of the Hg0.3La0.7Ba2Ca3(Cu0.95Ag0.5)4O10+δ superconductor

    NASA Astrophysics Data System (ADS)

    Mostafa, M. F.; Hassen, A.

    2016-09-01

    In this work, the temperature, magnetic field and frequency dependence of the ac susceptibility of Hg0.3La0.7Ba2Ca3(Cu0.95Ag0.5)4O10+δ were studied. The superconductivity still survives even at this amount of Ag. The magnetic field dependence of the irreversibility line (IL) and the flux pinning of this compound are discussed and compared with those of low Ag content. The IL exhibits thermally activated behaviour. A collective creep of the vortex bundle also occurs for this level of doping. A crossover from a two- to a three-dimensional system is suggested at T/Tc = 0.75 and a magnetic field, Hdc = 0.04 T. Based on vortex glass phase transition theory, the effective pinning energy, ueff, was calculated. The change in the characteristic temperature of the studied compound and that of low Ag content samples are summarised. Comparisons with similar materials are discussed.

  20. AC heat capacities of κ-(BEDT-TTF)2Cu2(CN)3 measured by microchip calorimeter

    NASA Astrophysics Data System (ADS)

    Muraoka, Y.; Yamashita, S.; Yamamoto, T.; Nakazawa, Y.

    2011-09-01

    Thermodynamic measurements of an organic spin liquid compound of κ-(BEDT-TTF)2Cu2(CN)3 where BEDT-TTF is bis(ethylenedithio)tetrathiafulvalene were performed by the ac calorimetry technique using a microchip device of TCG3880. This technique is effective to measure relative temperature and magnetic-field dependences of heat capacity for tiny single crystal samples less than 1μg. Broad hump structures in Cp vs T which are known as so-called 6 K anomaly were observed in κ-(BEDT-TTF)2Cu2(CN)3 and its deuterated compound. The hump temperatures are evaluated as 5.7 K in both compounds. This result demonstrates that the TCG3880 is useful for performing thermodynamic investigations of such kind of organic charge transfer complexes with much reduced sample quantity than the conventional techniques and that the existence of hump structure is intrinsic for κ-(BEDT-TTF)2Cu2(CN)3. The in-plane angular dependence of the magnetic field of 7 T applied parallel to the two dimensional layer is also studied and absence of in-plane anisotropy of the hump structure is discussed in both pristine and deuterated compounds.

  1. Tl 2Ba 2CaCu 2O 8- x superconducting films deposited by aerosol and their hysteretic ac losses

    NASA Astrophysics Data System (ADS)

    Conde-Gallardo, A.; Klein, T.; Escribe-Filippini, C.; Marcus, J.; Lopez-Rios, T.; Jergel, M.

    1998-04-01

    ac susceptibility measurements have been performed on Tl 2Ba 2CaCu 2O 8- x superconducting films. The films were grown in two steps: first Ba-Ca-Cu-Ag-O precursor films have been prepared by spraying an aerosol on MgO substrates and the Tl was then subsequently introduced by diffusion into the precursor films. The most favourable preparation conditions have been determined by comparing the structural and magnetic properties of the films. A detailed study of the ac susceptibility shows that the ac losses are due to intragrain bulk hysteretic pinning eventhough small geometrical barriers contributions could also be observed.

  2. Estimation of Density of Localized States in Amorphous Se80Te20 and Se80Te10M10 (M = Cd, In, Sb) Alloys Using AC Conductivity Measurements

    NASA Astrophysics Data System (ADS)

    Chandel, N.; Mehta, N.; Kumar, A.

    2015-08-01

    The ac conductivity of amorphous Se80Te20 (a-Se80Te20) and amorphous Se80Te10M10 (a-Se80Te10M10) alloys has been measured as a function of temperature and frequency in a low-temperature regime. An analysis of the experimental data confirms that ac conductivity is reasonably well interpreted by the Austin-Mott model. The density of localized states was determined in the low-temperature region from 201 K to 280 K. Possible explanations of "metal-induced effects" on the conduction mechanism of a-Se80Te20 alloy are discussed.

  3. A single-shot spatial chirp method for measuring initial AC conductivity evolution of femtosecond laser pulse excited warm dense matter

    SciTech Connect

    Chen, Z.; Hering, P.; Brown, S. B.; Curry, C.; Tsui, Y. Y.; Glenzer, S. H.

    2016-09-19

    To study the rapid evolution of AC conductivity from ultrafast laser excited warm dense matter (WDM), a spatial chirp single-shot method is developed utilizing a crossing angle pump-probe configuration. The pump beam is shaped individually in two spatial dimensions so that it can provide both sufficient laser intensity to excite the material to warm dense matter state and a uniform time window of up to 1 ps with sub-100 fs FWHM temporal resolution. Here, temporal evolution of AC conductivity in laser excited warm dense gold was also measured.

  4. A single-shot spatial chirp method for measuring initial AC conductivity evolution of femtosecond laser pulse excited warm dense matter.

    PubMed

    Chen, Z; Hering, P; Brown, S B; Curry, C; Tsui, Y Y; Glenzer, S H

    2016-11-01

    To study the rapid evolution of AC conductivity from ultrafast laser excited warm dense matter (WDM), a spatial chirp single-shot method is developed utilizing a crossing angle pump-probe configuration. The pump beam is shaped individually in two spatial dimensions so that it can provide both sufficient laser intensity to excite the material to warm dense matter state and a uniform time window of up to 1 ps with sub-100 fs FWHM temporal resolution. Temporal evolution of AC conductivity in laser excited warm dense gold was also measured.

  5. Managing What We Can Measure: Quantifying the Susceptibility of Automated Scoring Systems to Gaming Behavior

    ERIC Educational Resources Information Center

    Higgins, Derrick; Heilman, Michael

    2014-01-01

    As methods for automated scoring of constructed-response items become more widely adopted in state assessments, and are used in more consequential operational configurations, it is critical that their susceptibility to gaming behavior be investigated and managed. This article provides a review of research relevant to how construct-irrelevant…

  6. Exploring the origins of echo-time-dependent quantitative susceptibility mapping (QSM) measurements in healthy tissue and cerebral microbleeds.

    PubMed

    Cronin, Matthew J; Wang, Nian; Decker, Kyle S; Wei, Hongjiang; Zhu, Wen-Zhen; Liu, Chunlei

    2017-04-01

    Quantitative susceptibility mapping (QSM) is increasingly used to measure variation in tissue composition both in the brain and in other areas of the body in a range of disease pathologies. Although QSM measurements were originally believed to be independent of the echo time (TE) used in the gradient-recalled echo (GRE) acquisition from which they are derived; recent literature (Sood et al., 2016) has shown that these measurements can be highly TE-dependent in a number of brain regions. In this work we systematically investigate possible causes of this effect through analysis of apparent frequency and QSM measurements derived from data acquired at multiple TEs in vivo in healthy brain regions and in cerebral microbleeds (CMBs); QSM data acquired in a gadolinium-doped phantom; and in QSM data derived from idealized simulated phase data. Apparent frequency measurements in the optic radiations (OR) and central corpus callosum (CC) were compared to those predicted by a 3-pool white matter model, however the model failed to fully explain contrasting frequency profiles measured in the OR and CC. Our results show that TE-dependent QSM measurements can be caused by a failure of phase unwrapping algorithms in and around strong susceptibility sources such as CMBs; however, in healthy brain regions this behavior appears to result from intrinsic non-linear phase evolution in the MR signal. From these results we conclude that care must be taken when deriving frequency and QSM measurements in strong susceptibility sources due to the inherent limitations in phase unwrapping; and that while signal compartmentalization due to tissue microstructure and content is a plausible cause of TE-dependent frequency and QSM measurements in healthy brain regions, better sampling of the MR signal and more complex models of tissue are needed to fully exploit this relationship.

  7. A method for the integration of satellite vegetation activities observations and magnetic susceptibility measurements for monitoring heavy metals in soil.

    PubMed

    D'Emilio, Mariagrazia; Macchiato, Maria; Ragosta, Maria; Simoniello, Tiziana

    2012-11-30

    We present a procedure for monitoring heavy metals in soil based on the integration of satellite and ground-based techniques, tested in an area affected by high anthropogenic pressure. High resolution multispectral satellite data were elaborated to obtain information on vegetation status. Magnetic susceptibility measurements of soils were collected as proxy variable for monitoring heavy metal presence. Chemical analyses of heavy metals were used for supporting and validating the integrated monitoring procedure. Magnetic and chemical measurements were organized in a GIS environment to be overlapped to satellite-based elaborations and to analyze the pattern distribution. Results show the presence of correlation between anomalies in vegetation activity and soil characteristics. The relationship between the distribution of normalized difference vegetation index anomalies and magnetic susceptibility values provides hints for adopting the integrated procedure as preliminary screening to minimize monitoring efforts and costs by supporting the planning activities of field campaigns.

  8. A novel method to measure HLA-DM-susceptibility of peptides bound to MHC class II molecules based on peptide binding competition assay and differential IC(50) determination.

    PubMed

    Yin, Liusong; Stern, Lawrence J

    2014-04-01

    HLA-DM (DM) functions as a peptide editor that mediates the exchange of peptides loaded onto MHCII molecules by accelerating peptide dissociation and association kinetics. The relative DM-susceptibility of peptides bound to MHCII molecules correlates with antigen presentation and immunodominance hierarchy, and measurement of DM-susceptibility has been a key effort in this field. Current assays of DM-susceptibility, based on differential peptide dissociation rates measured for individually labeled peptides over a long time base, are difficult and cumbersome. Here, we present a novel method to measure DM-susceptibility based on peptide binding competition assays performed in the presence and absence of DM, reported as a delta-IC(50) (change in 50% inhibition concentration) value. We simulated binding competition reactions of peptides with various intrinsic and DM-catalyzed kinetic parameters and found that under a wide range of conditions the delta-IC(50) value is highly correlated with DM-susceptibility as measured in off-rate assay. We confirmed experimentally that DM-susceptibility measured by delta-IC(50) is comparable to that measured by traditional off-rate assay for peptides with known DM-susceptibility hierarchy. The major advantage of this method is that it allows simple, fast and high throughput measurement of DM-susceptibility for a large set of unlabeled peptides in studies of the mechanism of DM action and for identification of CD4+ T cell epitopes.

  9. Magnetoresistance, susceptibility and magnetization measurements on RNiBC compounds (R = Er, Ho, Dy, Tb, and Gd)

    NASA Astrophysics Data System (ADS)

    Tróchez, J. C.; Sánchez, D. R.; Giordanengo, B.; Fontes, M. B.; Continentino, Múcio; Baggio-Saitovitch, E. M.

    1997-08-01

    We studied magnetic behavior of the RNiBC compounds by magnetic and transport measurements. At low temperatures, each compound has different magnetic structure. Magnetoresistivity data are in good accordance with theory of magnetic elementary interactions, susceptibility reveals the magnetic transition and Curie Weiss behavior and magnetization shows low value of the saturation compared with the free R+3 ion that confirm that crystalline electric field is strong as in the RNi2B2C series.

  10. A simple AC calorimeter for specific heat measurement of liquids confined in porous materials: A study of hydrated Vycor

    NASA Astrophysics Data System (ADS)

    Bonetti, Marco; Zanotti, Jean-Marc

    2016-09-01

    Nanometric confinement of fluids in porous media is a classical way to stabilize metastable states. Calorimetric studies give insight on the behavior of confined liquids compared to bulk liquids. We have developed and built a simple quasi-adiabatic AC calorimeter for heat capacity measurement of confined liquids in porous media in a temperature range between 150 K and 360 K. Taking the fully hydrated porous medium as a reference, we address the thermal behavior of water as a monolayer on the surface of a porous silica glass (Vycor). For temperature ranging between 160 K and 325 K, this interfacial water shows a surprisingly large heat capacity. We describe the interfacial Hbond network in the framework of a mean field percolation model, to show that at 160 K interfacial water experiences a transformation from low density amorphous ice to a heterogeneous system where transient low and high density water patches coexist. The fraction of each species is controlled by the temperature. We identify the large entropy of the interfacial water molecules as the cause of this behaviour.

  11. Comparison of the accuracy of disk diffusion zone diameters obtained by manual zone measurements to that by automated zone measurements to determine antimicrobial susceptibility.

    PubMed

    Lestari, Endang Sri; Severin, Juliëtte A; Filius, P Margreet G; Kuntaman, Kuntaman; Offra Duerink, D; Hadi, Usman; Wahjono, Hendro; Verbrugh, Henri A

    2008-10-01

    Although a variety of techniques are available for antimicrobial susceptibility testing, disk diffusion methods remain the most widely used. We compared the accuracy of disk diffusion zone diameters as obtained by manual zone measurements in a low resource country (Indonesia) to that by automated zone measurements (Oxoid aura image system) in a high resource setting (the Netherlands) to determine susceptibility categories (sensitive, intermediate susceptible or resistant). A total of 683 isolates were studied, including 294 Staphylococcus aureus, 195 Escherichia coli and 194 other Enterobacteriaceae. Antimicrobial agents included tetracycline, oxacillin, gentamicin, erythromycin, trimethoprim/sulfamethoxazole and chloramphenicol for S. aureus and ampicillin, gentamicin, cefotaxime, ciprofloxacin, trimethoprim/sulfamethoxazole, and chloramphenicol for E. coli and other Enterobacteriaceae. Of the 4098 drug-organism combinations, overall category agreement (CA), major discrepancy (MD) and minor discrepancy (mD) between the two methods were 82.4% (3379/4098), 6.0% (244/4098) and 11.6% (475/4098), respectively. One hundred and sixty three of 244 MDs were resolved using reference broth microdilution method. Overall very major error (VME), major error (ME) and minor error (mE) of manual zone measurement were 28.8%, 45.4% and 4.9%, respectively and for the aura image system 4.9%, 16.0% and 4.9%, respectively. The results of this study indicate that the disk diffusion method with manual zone measurement in Indonesia is reliable for susceptibility testing. The use of an automated zone reader, such as the aura image system, will reduce the number of errors, and thus improve the accuracy of susceptibility test results for medically relevant bacteria.

  12. Separation of field-independent and field-dependent susceptibility tensors using a sequence of fully automated AMS measurements

    NASA Astrophysics Data System (ADS)

    Studynka, J.; Chadima, M.; Hrouda, F.; Suza, P.

    2013-12-01

    Low-field magnetic susceptibility of diamagnetic and paramagnetic minerals as well as that of pure magnetite and all single-domain ferromagnetic (s.l.) minerals is field-independent. In contrast, magnetic susceptibility of multi-domain pyrrhotite, hematite and titanomagnetite may significantly depend on the field intensity. Hence, the AMS data acquired in various fields have a great potential to separate the magnetic fabric carried by the latter group of minerals from the whole-rock fabric. The determination of the field variation of AMS consist of separate measurements of each sample in several fields within the Rayleigh Law range and subsequent processing in which the field-independent and field-dependent susceptibility tensors are calculated. The disadvantage of this technique is that each sample must be measured several times in various positions, which is relatively laborious and time consuming. Recently, a new 3D rotator was developed for the MFK1 Kappabridges which rotates the sample simultaneously about two axes with different velocities. The measurement is fully automated in such a way that, once the sample is mounted into the rotator, it requires no additional positioning to measure the full AMS tensor. The important advantage of the 3D rotator is that it enables to measure AMS in a sequence of pre-set field intensities without any operator manipulation. Whole procedure is computer-controlled and, once a sequence of measurements is finished, the acquired data are immediately processed and visualized. Examples of natural rocks demonstrating various types of field dependence of AMS are given.

  13. Magnetic susceptibility measurements as proxy method to monitor soil pollution: the case study of S. Nicola di Melfi.

    PubMed

    D'Emilio, Mariagrazia; Caggiano, Rosa; Coppola, Rosa; Macchiato, Maria; Ragosta, Maria

    2010-10-01

    The development of in situ, cheep, noninvasive, and fast strategies for soil monitoring is a crucial task for environmental research. In this paper, we present the results of three field surveys carried out in an industrial area of Southern Italy: S. Nicola di Melfi. The monitoring procedure is based on soil magnetic susceptibility measurements carried out by means of experimental protocols that our research group developed during the last years. This field surveys is supported by both geological characterization of the area and analytical determinations of metal concentrations in soils. Magnetic studies were carried out not only in situ but also in laboratory. Results show that, taking into account the influence due to the geomorphologic difference, soil magnetic susceptibility is an optimal indicator of the anthropogenic impact. So, our monitoring strategy discloses that the combined use of magnetic susceptibility measurements and soil geomorphology information may be used as a useful tool for the temporal monitoring of pollution evolution and for a fast screening of polluted zones.

  14. Magnetic susceptibility and magnetic resonance measurements of the moisture content and hydration condition of a magnetic mixture material

    SciTech Connect

    Tsukada, K. Kusaka, T.; Saari, M. M.; Takagi, R.; Sakai, K.; Kiwa, T.; Bito, Y.

    2014-05-07

    We developed a magnetic measurement method to measure the moisture content and hydration condition of mortar as a magnetic mixture material. Mortar is a mixture of Portland cement, sand, and water, and these materials exhibit different magnetic properties. The magnetization–magnetic field curves of these components and of mortars with different moisture contents were measured, using a specially developed high-temperature-superconductor superconducting quantum interference device. Using the differences in magnetic characteristics, the moisture content of mortar was measured at the ferromagnetic saturation region over 250 mT. A correlation between magnetic susceptibility and moisture content was successfully established. After Portland cement and water are mixed, hydration begins. At the early stage of the hydration/gel, magnetization strength increased over time. To investigate the magnetization change, we measured the distribution between bound and free water in the mortar in the early stage by magnetic resonance imaging (MRI). The MRI results suggest that the amount of free water in mortar correlates with the change in magnetic susceptibility.

  15. Relation of motion sickness susceptibility to vestibular and behavioral measures of orientation

    NASA Technical Reports Server (NTRS)

    Peterka, Robert J.

    1995-01-01

    The objective is to determine the relationship of motion sickness susceptibility to vestibulo-ocular reflexes (VOR), motion perception, and behavioral utilization of sensory orientation cues for the control of postural equilibrium. The work is focused on reflexes and motion perception associated with pitch and roll movements that stimulate the vertical semicircular canals and otolith organs of the inner ear. This work is relevant to the space motion sickness problem since 0 g related sensory conflicts between vertical canal and otolith motion cues are a likely cause of space motion sickness.

  16. Examination of Humidity Effects on Measured Thickness and Interfacial Phenomena of Exfoliated Graphene on SiO2 via AC-AFM

    NASA Astrophysics Data System (ADS)

    Jinkins, Katherine; Camacho, Jorge; Farina, Lee; Wu, Yan

    2015-03-01

    Tapping (AC) mode Atomic Force Microscopy (AFM) is commonly used to determine the thickness of graphene samples. However, AFM measurements have been shown to be sensitive to environmental conditions such as adsorbed water, in turn dependent on relative humidity (RH). In the present study, AC-AFM is used to measure the thickness and loss tangent of exfoliated graphene on silicon dioxide (SiO2) as RH is increased from 10% to 80%. We show that the measured thickness of graphene is dependent on RH. Loss tangent is an AFM imaging technique that interprets the phase information as a relationship between the stored and dissipated energy in the tip-sample interaction. This study demonstrates the loss tangent of the graphene and oxide regions are both affected by humidity, with generally higher loss tangent for graphene than SiO2. As RH increases, we observe the loss tangent of both materials approaches the same value. We hypothesize that there is a layer of water trapped between the graphene and SiO2 substrate to explain this observation. Using this interpretation, the loss tangent images also indicate movement and change in this trapped water layer as RH increases, which impacts the measured thickness of graphene using AC-AFM.

  17. Changes in brain iron concentration after exposure to high-altitude hypoxia measured by quantitative susceptibility mapping.

    PubMed

    Chen, Lin; Cai, Congbo; Yang, Tianhe; Lin, Jianzhong; Cai, Shuhui; Zhang, Jiaxing; Chen, Zhong

    2017-02-15

    Hypoxia can induce physiological changes. This study aims to explore effects of high-altitude (HA) hypoxia on cerebral iron concentration. Twenty-nine healthy sea-level participants were tested shortly before and after approximately 4-week adaptation to the HA environment at fQinghai-Tibet Plateau (4200m), and were re-investigated after re-adaptation to the sea-level environment one year later. Iron concentration was quantified with quantitative susceptibility mapping (QSM), and the results were compared with transverse relaxation rate (R(*)2) measurements. The variations of magnetic susceptibility indicate that the iron concentration in gray matter regions, especially in basal ganglia, including caudate nucleus, putamen, globus pallidus and substantia nigra, increases significantly after HA exposure. This increase appears consistent with the conclusion from R(*)2 value variations. However, unlike QSM, the R(*)2 value fails to demonstrate the statistical difference of iron content in red nucleus. The re-investigation results show that most variations are recovered after sea-level re-adaptation for one year. Additionally, hemisphere- and gender-related differences in iron concentration changes were analyzed among cerebral regions. The results show greater possibilities in the right hemisphere and females. Further studies based on diffusion tensor imaging (DTI) suggest that the fractional anisotropy increases and the mean diffusivity decreases after HA exposure in six deep gray matter nuclei, with linear dependence on iron concentration only in putamen. In conclusion, the magnetic susceptibility value can serve as a quantitative marker of brain iron, and variations of regional susceptibility reported herein indicate that HA hypoxia can result in significant iron deposition in most deep gray matter regions. Additionally, the linear dependence of DTI metrics on iron concentration in putamen indicates a potential relationship between ferritin and water diffusion.

  18. Structural and AC loss study for pure and doped MgB2 superconductor

    NASA Astrophysics Data System (ADS)

    Hansdah, J. S.; Sarun, P. M.

    2015-06-01

    Superconducting polycrystalline bulk MgB2 samples doped with n-C, n-Y2O3 and n-Ho2O3 were prepared by powder-in-sealed (PIST) method. XRD measurement shows the influence of dopants on phase and lattice parameters of samples. The ac susceptibility measurement reveals ac loss and activation energy of the samples. Nano-C doped sample shows less ac loss in all frequency (208 Hz - 999 Hz) among the doped samples; whereas n-Ho2O3 doped sample shows highest ac loss. The activation energy is high for rare earth (n-Y2O3 and n-Ho2O3) doped samples as compare to n-C doped samples which reveals the enhancement in flux-pinning properties of these materials.

  19. Structural and AC loss study for pure and doped MgB{sub 2} superconductor

    SciTech Connect

    Hansdah, J. S.; Sarun, P. M.

    2015-06-24

    Superconducting polycrystalline bulk MgB{sub 2} samples doped with n-C, n-Y{sub 2}O{sub 3} and n-Ho{sub 2}O{sub 3} were prepared by powder-in-sealed (PIST) method. XRD measurement shows the influence of dopants on phase and lattice parameters of samples. The ac susceptibility measurement reveals ac loss and activation energy of the samples. Nano-C doped sample shows less ac loss in all frequency (208 Hz – 999 Hz) among the doped samples; whereas n-Ho{sub 2}O{sub 3} doped sample shows highest ac loss. The activation energy is high for rare earth (n-Y{sub 2}O{sub 3} and n-Ho{sub 2}O{sub 3}) doped samples as compare to n-C doped samples which reveals the enhancement in flux-pinning properties of these materials.

  20. Measurement of Meteorite Density, Porosity and Magnetic Susceptibility: Fast, Non- destructive, Non-contaminating and Very Informative

    NASA Astrophysics Data System (ADS)

    Macke, R. J.; Britt, D. T.; Consolmagno, G. J.

    2009-05-01

    The development of the "glass bead" method [1] for measuring bulk density, coupled with other fast, non- destructive and non-contaminating methods for measuring grain density and magnetic susceptibility, has enabled broad surveys of large meteorite collections. We have employed these methods extensively on meteorites in numerous collections, including those at the Vatican, the American Museum of Natural History (New York), the National Museum of Natural History (Washington, DC), Texas Christian University, University of New Mexico, and Arizona State University. We present here a summary of some of the findings to date. Using the glass bead method, the meteorite is placed into a container which is then filled entirely with small (sub- millimeter) glass beads. The beads behave collectively as an Archimedean fluid, flowing around the sample to fill the empty space in the container. Through mass measurement, the volume displaced by the sample can be determined. Grain density is determined via helium ideal-gas pycnometry. Magnetic susceptibility is determined using a commercially available hand-held device [2]. Among notable findings to date, grain density and magnetic susceptibility together can distinguish H, L and LL ordinary chondrite falls into clearly distinct groupings [3]. On the other hand, enstatite chondrites of EH and EL subgroups are indistinguishable in these properties, indicating that EH and EL do not differ significantly in iron content [4]. Carbonaceous chondrites can have porosities that are significantly higher than ordinary chondrites and (especially for aqueously altered meteorites) lower density, though these also vary according to subgroups [5]. References: [1] Consolmagno and Britt, 1998. M&PS 33, 1231-1240. [2] Gattacceca et al., 2004. GJI 158, 42-49. [3] Consolmagno et al., 2006. M&PS 41, 331-342. [4] Macke et al., 2009. LPSC 40, 1598. [5] Consolmagno et al., 2008. MetSoc 71, 5038.

  1. Implications of Late Pliocene-Pleistocene Humidity Fluctuations in the Qaidam Paleolake (NE Tibetan Plateau) Deduced from Magnetic Susceptibility Measurements

    NASA Astrophysics Data System (ADS)

    Herb, C.; Appel, E.; Koutsodendris, A.; Zhang, W.; Pross, J.; Fang, X.

    2014-12-01

    The Qaidam Basin (NE Tibetan Plateau) contains a near-continuous, up to 12 km thick sequence of Cenozoic strata that offers a unique opportunity for studying long-term climate change. We investigate the 940-m-long drill core SG-1 from the western Qaidam Basin, which is characterized by a long-term transition from a semi-deep freshwater lake to nearly complete exsiccation of the water body, detected by several studies including geochemical and lithological observations. Based on magnetostratigraphy and optically stimulated luminescence dating, and refined by orbital tuning, the SG-1 core spans the interval from 2.69 to 0.1 Ma. Moisture availability in the western Qaidam Basin deduced from the pollen ratio Artemisia/Chenopodiaceae (A/C), suggests desert to steppe vegetation along core SG-1 as a long-term feature. Magnetic susceptibility (χ) is well suited for the high-resolution investigation of paleohumidity. The meaning of χ as a paleohydrology proxy is shown by comparing χ to other magnetic proxies for checking its relation to magnetic grain sizes and magnetic mineralogy as well as to pollen results. χ variations are analyzed to obtain regional information on the factors leading to the drying process of the Qaidam paleolake as well as potential driving factors for humidity fluctuations (e.g., insolation). An important topic that needs further investigation is the influence of monsoon in the Qaidam Basin. While the southern part of the Tibetan Plateau is directly affected by monsoon precipitation through the topographic barrier, its influence in the past is questionable in the hyper-arid Qaidam Basin. We check a potential coupling to the monsoon system in the western Qaidam Basin by comparing our χ record to reconstructions of the Asian monsoon system from other archives as well as searching evidence from orbital cyclicities found in the χ time series.

  2. Relation of motion sickness susceptibility to vestibular and behavioral measures of orientation

    NASA Technical Reports Server (NTRS)

    Peterka, Robert J.

    1994-01-01

    The objective of this proposal is to determine the relationship of motion sickness susceptibility to vestibulo-ocular reflexes (VOR), motion perception, and behavioral utilization of sensory orientation cues for the control of postural equilibrium. The work is focused on reflexes and motion perception associated with pitch and roll movements that stimulate the vertical semicircular canals and otolith organs of the inner ear. This work is relevant to the space motion sickness problem since 0 g related sensory conflicts between vertical canal and otolith motion cues are a likely cause of space motion sickness. Results of experimentation are summarized and modifications to a two-axis rotation device are described. Abstracts of a number of papers generated during the reporting period are appended.

  3. The hippocampus may be more susceptible to environmental noise than the auditory cortex.

    PubMed

    Cheng, Liang; Wang, Shao-Hui; Huang, Yun; Liao, Xiao-Mei

    2016-03-01

    Noise exposure can cause structural and functional problem in the auditory cortex (AC) and hippocampus, the two brain regions in the auditory and non-auditory systems respectively. The aim of the present study was to explore which one of these two brain regions may be more susceptible to environmental noise. The AC and hippocampus of mice were separated following 1 or 3 weeks exposure to moderate noise (80 dB SPL, 2 h/day). The levels of oxidative stress and tau phosphorylation were then measured to evaluate the effects by noise. Results showed significant peroxidation and tau hyperphosphorylation in the hippocampus with 1 week of noise exposure. However, the AC did not show significant changes until exposure for 3 weeks. These data suggest that although the hippocampus and AC were affected by moderate noise exposure, the hippocampus in the non-auditory system may have been more vulnerable to environmental noise than the AC.

  4. Mutual-induction measurement of the AC penetration depth in HTSC's theory of calibration function for flat samples under axial symmetry

    NASA Astrophysics Data System (ADS)

    Klupsch, Th.; Zeisberger, M.

    1995-02-01

    A contribution to find optimum mutual-induction arrangements for investigating the linear AC response properties of the pinned vortices in the mixed state of HTSC is given. In particular, the complex calibration function (mutual-induction coefficient L12 as a function of the complex AC penetration depth λ) is analyzed, strictly axial symmetry and flat sample geometries provided (finite disk and its limiting case of infinite platelet) assuming the radius of at least one induction coil is smaller than the sample radius. Because the sample is positioned transverse to the AC induction B, the mutual inductance becomes, in general, strongly modified by distortions of B around the sample, which results in a strong dependence of L12(λ) upon certain geometry parameters and an enhanced sensitivity to λ for selected |λ| intervals. The analysis is based upon powerful analytic approximation formulae for elementary arrangements derived in a separate paper. Also, formulae to estimate the errors from irregular (eccentric) sample shapes, from the field enhancement near the disk edges as well as from treating the finite-disk problem in the limit of an infinite platelet are given. Except for ultrathin films with thickness much smaller than |λ|, arrangements with both the coils at the same sample side and with the loop radii sufficiently smaller than the disk radius are favored for measurements of small λ with |D/λ| ≳ 1 ( D is the sample thickness), which also includes the possibility of a λ measurement in the bulk limit | D/λ| → ∞.

  5. Magnetic susceptibility measurements to detect coal fly ash from the Kingston Tennessee spill in Watts Bar Reservoir.

    PubMed

    Cowan, Ellen A; Seramur, Keith C; Hageman, Steven J

    2013-03-01

    An estimated 229,000 m(3) of coal fly ash remains in the river system after dredging to clean-up the 2008 Tennessee Valley Authority (TVA) spill in Kingston, Tennessee. The ash is heterogeneous with clear, orange and black spheres and non-spherical amorphous particles. Combustion produces iron oxides that allow low field magnetic susceptibility (χ(LF)) and percent frequency dependent susceptibility (χ(FD)%) to be used to discriminate between coal fly ash and sediments native to the watershed. Riverbed samples with χ(LF) greater than 3.0 × 10(-6) m(3)/kg, have greater than 15% ash measured by optical point counting. χ(LF) is positively correlated with total ash, allowing ash detection in riverbed sediments and at depth in cores. The ratio of ash sphere composition is altered by river transport introducing variability in χ(LF). Measurement of χ(LF) is inexpensive, non-destructive, and a reliable analytical tool for monitoring the fate of coal ash in this fluvial environment.

  6. Performance measurements and operational characteristics of the Storage Tek ACS 4400 tape library with the Cray Y-MP EL

    NASA Technical Reports Server (NTRS)

    Hull, Gary; Ranade, Sanjay

    1993-01-01

    With over 5000 units sold, the Storage Tek Automated Cartridge System (ACS) 4400 tape library is currently the most popular large automated tape library. Based on 3480/90 tape technology, the library is used as the migration device ('nearline' storage) in high-performance mass storage systems. In its maximum configuration, one ACS 4400 tape library houses sixteen 3480/3490 tape drives and is capable of holding approximately 6000 cartridge tapes. The maximum storage capacity of one library using 3480 tapes is 1.2 TB and the advertised aggregate I/O rate is about 24 MB/s. This paper reports on an extensive set of tests designed to accurately assess the performance capabilities and operational characteristics of one STK ACS 4400 tape library holding approximately 5200 cartridge tapes and configured with eight 3480 tape drives. A Cray Y-MP EL2-256 was configured as its host machine. More than 40,000 tape jobs were run in a variety of conditions to gather data in the areas of channel speed characteristics, robotics motion, time taped mounts, and timed tape reads and writes.

  7. Measurement of submilliwatt, picosecond terahertz emission from a femtosecond-laser-pumped solid-state dc to ac radiation converter based on a ZnSe crystal

    SciTech Connect

    Yugami, Noboru; Ohata, Nobuo; Yaegashi, Kenta; Kawanago, Hiroshi

    2006-11-15

    We measured the terahertz pulse emission from a femtosecond-laser-pumped solid-state dc to ac radiation converter using a 150 fs Ti:sapphire laser pulse for dense plasma diagnostics. The laser-produced ionization front was directly modulated from a periodic electrostatic field to pulsed emission. The central frequency of the emission was measured to be 0.13 THz having a bandwidth of 0.1 THz and a peak power of 0.2 mW. This emission source is suitable for use in various novel diagnostic techniques, such as dense plasma diagnostics.

  8. Tevatron AC dipole system

    SciTech Connect

    Miyamoto, R.; Kopp, S.E.; Jansson, A.; Syphers, M.J.; /Fermilab

    2007-06-01

    The AC dipole is an oscillating dipole magnet which can induce large amplitude oscillations without the emittance growth and decoherence. These properties make it a good tool to measure optics of a hadron synchrotron. The vertical AC dipole for the Tevatron is powered by an inexpensive high power audio amplifier since its operating frequency is approximately 20 kHz. The magnet is incorporated into a parallel resonant system to maximize the current. The use of a vertical pinger magnet which has been installed in the Tevatron made the cost relatively inexpensive. Recently, the initial system was upgraded with a more powerful amplifier and oscillation amplitudes up to 2-3{sigma} were achieved with the 980 GeV proton beam. This paper discusses details of the Tevatron AC dipole system and also shows its test results.

  9. Methods of measuring zones of inhibition with the Bauer-Kirby disk susceptibility test.

    PubMed

    Barry, A L; Coyle, M B; Thornsberry, C; Gerlach, E H; Hawkinson, R W

    1979-12-01

    Standard Bauer-Kirby disk tests were performed with 85 selected isolates, each tested in triplicate by four different investigators. Each disk test was observed, and zone diameters were measured, under two lighting conditions (transmitted light and reflected light). The two lighting systems produced similar zone measurements (+/-2 mm) with 96% of the tests. When there were greater differences, zones appeared to be larger when observed with reflected light. Interlaboratory reproducibility was much greater when using reflected light rather than transmitted light. We concluded that zone diameters should be measured from the back of the plate while it is resting on, or held 2 to 3 inches [ca. 5.1 to 7.6 cm] above, a black, nonreflecting, flat surface, illuminated by a reflected light source.

  10. Vertical impedance measurements on concrete bridge decks for assessing susceptibility of reinforcing steel to corrosion.

    PubMed

    Bartholomew, Paul D; Guthrie, W Spencer; Mazzeo, Brian A

    2012-08-01

    Corrosion is a pressing problem for aging concrete infrastructure, especially bridge decks. Because of its sensitivity to factors that affect corrosion of reinforcing steel in concrete, resistivity is an important structural health indicator for reinforced concrete structures. In this research, an instrument was developed to measure vertical impedance on concrete bridge decks. Measurements of vertical impedance on slabs prepared in the laboratory, on slabs removed from decommissioned bridge decks, and on an in-service bridge deck in the field demonstrate the utility of the new apparatus.

  11. Vertical impedance measurements on concrete bridge decks for assessing susceptibility of reinforcing steel to corrosion

    NASA Astrophysics Data System (ADS)

    Bartholomew, Paul D.; Guthrie, W. Spencer; Mazzeo, Brian A.

    2012-08-01

    Corrosion is a pressing problem for aging concrete infrastructure, especially bridge decks. Because of its sensitivity to factors that affect corrosion of reinforcing steel in concrete, resistivity is an important structural health indicator for reinforced concrete structures. In this research, an instrument was developed to measure vertical impedance on concrete bridge decks. Measurements of vertical impedance on slabs prepared in the laboratory, on slabs removed from decommissioned bridge decks, and on an in-service bridge deck in the field demonstrate the utility of the new apparatus.

  12. Susceptibility to peer influence: using a performance-based measure to identify adolescent males at heightened risk for deviant peer socialization.

    PubMed

    Prinstein, Mitchell J; Brechwald, Whitney A; Cohen, Geoffrey L

    2011-07-01

    A substantial amount of research has suggested that adolescents' attitudes and behaviors are influenced by peers; however, little is known regarding adolescents' individual variability, or susceptibility, to peer influence. In this study, a performance-based index from an experimental paradigm was used to directly measure adolescents' susceptibility to peers. A total of 36 adolescent boys participated in a "chat room" experiment in which they ostensibly were exposed to deviant or risky social norms communicated either by high-peer-status (i.e., popular, well-liked) or low-peer-status (i.e., unpopular, disliked) grade mates who actually were electronic confederates. Changes in adolescents' responses before and after exposure to peer norms were used as a measure of peer influence susceptibility. These same adolescents completed a questionnaire assessment at the study outset and again 18 months later to assess their actual engagement in deviant behavior and their perceptions of their best friend's engagement in deviant behavior. Only among adolescents with high levels of susceptibility to high-status peers was a significant longitudinal association revealed between their best friend's baseline deviant behavior and adolescents' own deviant behavior 18 months later. Findings support the predictive validity of a performance-based susceptibility measure and suggest that adolescents' peer influence susceptibility may generalize across peer contexts.

  13. Demonstrating and Measuring Relative Molar Magnetic Susceptibility Using a Neodymium Magnet

    ERIC Educational Resources Information Center

    Malerich, Charles; Ruff, Patricia K.; Bird, Aubrey

    2004-01-01

    An easy-to-see method for demonstrating and measuring the magnetic force between paramagnetic substance and a rare earth magnet is presented. The readily available trapezoid-shaped neodymium magnet and a low cost, easy-to-set-up, portable apparatus are used in the experiments.

  14. Torsional vestibulo-ocular reflex measurements for identifying otolith asymmetries possibly related to space motion sickness susceptibility

    NASA Technical Reports Server (NTRS)

    Peterka, R. J.

    1994-01-01

    Recent studies by Diamond and Markham have identified significant correlations between space motion sickness susceptibility and measures of disconjugate torsional eye movements recorded during parabolic flights. These results support an earlier proposal by von Baumgarten and Thumler which hypothesized that an asymmetry of otolith function between the two ears is the cause of space motion sickness. It may be possible to devise experiments that can be performed in the 1 g environment on earth that could identify and quantify the presence of asymmetric otolith function. This paper summarizes the known physiological and anatomical properties of the otolith organs and the properties of the torsional vestibulo-ocular reflex which are relevant to the design of a stimulus to identify otolith asymmetries. A specific stimulus which takes advantage of these properties is proposed.

  15. Torsional vestibulo-ocular reflex measurements for identifying otolith asymmetries possibly related to space motion sickness susceptibility

    NASA Technical Reports Server (NTRS)

    Peterka, Robert J.

    1993-01-01

    Recent studies have identified significant correlations between space motion sickness susceptibility and measures of disconjugate torsional eye movements recorded during parabolic flights. These results support an earlier proposal which hypothesized that an asymmetry of otolith function between the two ears is the cause of space motion sickness. It may be possible to devise experiments that can be performed in the 1 g environment on earth that could identify and quantify the presence of asymmetric otolith function. This paper summarizes the known physiological and anatomical properties of the otolith organs and the properties of the torsional vestibulo-ocular reflex which are relevant to the design of a stimulus to identify otolith asymmetries. A specific stimulus which takes advantage of these properties is proposed.

  16. Estimating the contribution of Brownian and Néel relaxation in a magnetic fluid through dynamic magnetic susceptibility measurements

    NASA Astrophysics Data System (ADS)

    Maldonado-Camargo, L.; Torres-Díaz, I.; Chiu-Lam, A.; Hernández, M.; Rinaldi, C.

    2016-08-01

    We demonstrate how dynamic magnetic susceptibility measurements (DMS) can be used to estimate the relative contributions of Brownian and Néel relaxation to the dynamic magnetic response of a magnetic fluid, a suspension of magnetic nanoparticles. The method applies to suspensions with particles that respond through Brownian or Néel relaxation and for which the characteristic Brownian and Néel relaxation times are widely separated. First, we illustrate this using magnetic fluids consisting of mixtures of particles that relax solely by the Brownian or Néel mechanisms. Then, it is shown how the same approach can be applied to estimate the relative contributions of Brownian and Néel relaxation in a suspension consisting of particles obtained from a single synthesis and whose size distribution straddles the transition from Néel to Brownian relaxation.

  17. Comparison of three patterns of feed supplementation with live Saccharomyces cerevisiae yeast on postweaning diarrhea, health status, and blood metabolic profile of susceptible weaning pigs orally challenged with Escherichia coli F4ac.

    PubMed

    Trevisi, P; Colombo, M; Priori, D; Fontanesi, L; Galimberti, G; Calò, G; Motta, V; Latorre, R; Fanelli, F; Mezzullo, M; Pagotto, U; Gherpelli, Y; D'Inca, R; Bosi, P

    2015-05-01

    The development of effective feeding strategies to reduce the detrimental effect of enterotoxigenic F4ac (ETEC) plays a crucial role in reducing the occurrence of therapeutic intervention with antibiotics in livestock. The ability of CNCM I-4407 (SCC), supplied in different patterns to counteract ETEC infection in weaned pigs, was evaluated. Fifty pigs weaned at 24 d were then divided into 5 groups: control (CO), CO + colistin (AB), CO + 5 × 10(10) cfu of SCC/ kg feed, from d 0 to 21 (PR), CO + 5 × 10(10) cfu of SCC/ kg feed from d 7 to 11 (CM), and CO + 1 shot of 2 × 10(11) cfu of SCC when the first diarrhea appeared (CU). On d 7 postweaning, all the pigs were orally challenged with 10(8) cfu of ETEC. Blood samples were taken from the pigs (d 7, 8, 12, and 21) while the fecal excretion of ETEC was assessed on d 7 and 10. Fecal consistency was scored from 12 h before infection to 144 h postinfection (p.i.). On d 21, the pigs were sacrificed. The in vitro adhesion test on the intestinal villi confirmed individual susceptibility to ETEC, excluding the presence of resistant pigs. Growth performance did not differ between the treatments. Mortality was reduced in the AB group (P< 0.01) and, marginally, in the PR group (P = 0.089) when compared to the CO group. The CO group had a higher fecal score than AB in the period of observation (from P = 0.01 to P< 0.001). Yeast administration reduced the fecal score when compared to the CO group 12 and 48 h p.i. (P = 0.04). Total IgA never differed among the treatments, but the ETEC-specific IgA concentration was lower in the AB group than in CO (P = 0.04) at d 12. Four days p.i., the pigs fed live yeast had reduced ETEC excretion compared with the CO pigs (P = 0.05). Blood concentrations of dodecenoyl-L-carnitine (P < 0.01), glutaryl-L-carnitine/hydroxyhex¬anoyl-L-carnitine, phosphatidylcholine diacyl and phosphatidylcholine diacyl (P = 0.01 and P< 0.01, respectively), and α-amino adipic acid (P < 0.01) were reduced in the

  18. The effect of diffusion and susceptibility differences on T2 measurements for fluids in porous media and biological tissues.

    PubMed

    Borgia, G C; Brown, R J; Fantazzini, P

    1996-01-01

    A number of features of T2 measurements for fluids in porous media have shown behavior contrary to that suggested by intuition developed in other areas. For porous media with relatively uniform pore spaces the following have been observed, in each case for certain ranges only of Xv (susceptibility difference times frequency), D (diffusion coefficient), a (a pore dimension), porespace shape and distribution, echo-time t for single echoes and half-echo-spacing tau for CPMG): (1) In S(t) for FID (free induction decay, S for signal) with constant slope after an initial period of increasing slope; (2) In Ss(t) for single (subscript s) echoes linear (instead of cubic) in t after an initial period; (3) for CPMG R(tau) = 1/T2(tau) - 1/T2(tau-->0) linear in tau over a substantial range; (4) slope of R(tau) independent of D and alpha for this range; (5) slope R(s) of In Ss(t) independent of D and a, and (6) R(s)(t) and R(tau) at long times linear (instead of quadratic) in Xv. These features appear to be compatible with the assumption of a truncated Cauchy-Lorentz distribution of the local magnetic fields due to susceptibility differences. The statistics of repeated sampling of local fields in different parts of the porespace during diffusion lead to a suppression, after a short time, of the effects of diffusion on the FID decay rate and the single-echo decay rate over significant ranges of the parameters. Data are presented to extend the range of parameters studied previously.

  19. Electrical characterization of Cu(In,Ga)Se2 thin films peeled off from Mo-coated soda-lime glass substrate by AC Hall measurement

    NASA Astrophysics Data System (ADS)

    Umehara, Takeshi; Iinuma, Shohei; Sadono, Adiyudha; Kurokawa, Yasuyoshi; Yamada, Akira

    2015-01-01

    We have developed a new evaluation method for electrical properties of Cu(In,Ga)Se2 (CIGS) grown on a Mo-coated soda-lime glass (SLG). The method consists of the peel-off process and the AC Hall measurement, which enables us to evaluate CIGS films grown on the Mo electrode. It was found, from the measurement, that the hole concentration of CIGS grown on a Mo-coated SLG was approximately two orders of magnitude higher than that on a SLG, suggesting the Na-doping effect. Furthermore, the hole mobility of 0.47 cm2/(V·s) was simultaneously measured, even though the film was deposited on the Mo electrode.

  20. Susceptibility Testing

    MedlinePlus

    ... Also known as: Sensitivity Testing; Drug Resistance Testing; Culture and Sensitivity; C & S; Antimicrobial Susceptibility Formal name: Bacterial and Fungal Susceptibility Testing Related tests: Urine Culture ; Blood Culture ; Bacterial Wound Culture ; AFB Testing ; MRSA ; ...

  1. Combining biofilm matrix measurements with biomass and viability assays in susceptibility assessments of antimicrobials against Staphylococcus aureus biofilms.

    PubMed

    Skogman, Malena Elise; Vuorela, Pia Maarit; Fallarero, Adyary

    2012-09-01

    Despite that three types of assays (measuring biofilm viability, biomass, or matrix) are described to assess anti-biofilm activity, they are rarely used together. As infections can easily reappear if the matrix is not affected after antibiotic treatments, our goal was to explore the simultaneous effects of antibiotics on the viability, biomass and matrix of Staphylococcus aureus biofilms (ATCC 25923). Viability and biomass were quantified using resazurin and crystal violet staining sequentially in the same plate, while matrix staining was conducted with a wheat germ agglutinin-Alexa Fluor 488 fluorescent conjugate. Establishment of the detection limits and linearity ranges allowed concluding that all three methods were able to estimate biofilm formation in a similar fashion. In a susceptibility study with 18-h biofilms, two model compounds (penicillin G and ciprofloxacin) caused a reduction on the viability and biomass accompanied by an increase or not changed levels of the matrix, respectively. This response pattern was also proven for S. aureus Newman, S. epidermidis and E. coli biofilms. A classification of antibiotics based on five categories according to their effects on viability and matrix has been proposed earlier. Our data suggests a sixth group, represented by penicillin, causing decrease in bacterial viability but showing stimulatory effects on the matrix. Further, if effects on the matrix are not taken into account, the long-term chemotherapeutic effect of antibiotics can be jeopardized in spite of the positive effects on biofilms viability and biomass. Thus, measuring all these three endpoints simultaneously provide a more complete and accurate picture.

  2. ac Stark shift measurements of the clock transition in cold Cs atoms: Scalar and tensor light shifts of the D2 transition

    NASA Astrophysics Data System (ADS)

    Costanzo, G. A.; Micalizio, S.; Godone, A.; Camparo, J. C.; Levi, F.

    2016-06-01

    The ac Stark shift, or light shift, is a physical phenomenon that plays a fundamental role in many applications ranging from basic atomic physics to applied quantum electronics. Here, we discuss experiments testing light-shift theory in a cold-atom cesium fountain clock for the Cs D2 transition (i.e., 6 2S1 /2→6 2P3 /2 at 852 nm). Cold-atom fountains represent a nearly ideal system for the study of light shifts: (1) The atoms can be perturbed by a field of arbitrary character (e.g., coherent field or nonclassical field); (2) there are no trapping fields to complicate data interpretation; (3) the probed atoms are essentially motionless in their center-of-mass reference frame, T ˜ 1 μK; and (4) the atoms are in an essentially collisionless environment. Moreover, in the present work the resolution of the Cs excited-state hyperfine splittings implies that the D2 ac Stark shift contains a nonzero tensor polarizability contribution, which does not appear in vapor phase experiments due to Doppler broadening. Here, we test the linearity of the ac Stark shift with field intensity, and measure the light shift as a function of field frequency, generating a "light-shift curve." We have improved on the previous best test of theory by a factor of 2, and after subtracting the theoretical scalar light shift from the experimental light-shift curves, we have isolated and tested the tensor light shift for an alkali D2 transition.

  3. AC photovoltaic module magnetic fields

    SciTech Connect

    Jennings, C.; Chang, G.J.; Reyes, A.B.; Whitaker, C.M.

    1997-12-31

    Implementation of alternating current (AC) photovoltaic (PV) modules, particularly for distributed applications such as PV rooftops and facades, may be slowed by public concern about electric and magnetic fields (EMF). This paper documents magnetic field measurements on an AC PV module, complementing EMF research on direct-current PV modules conducted by PG and E in 1993. Although not comprehensive, the PV EMF data indicate that 60 Hz magnetic fields (the EMF type of greatest public concern) from PV modules are comparable to, or significantly less than, those from household appliances. Given the present EMF research knowledge, AC PV module EMF may not merit considerable concern.

  4. Susceptibility to Peer Influence: Using a Performance-Based Measure to Identify Adolescent Males at Heightened Risk for Deviant Peer Socialization

    ERIC Educational Resources Information Center

    Prinstein, Mitchell J.; Brechwald, Whitney A.; Cohen, Geoffrey L.

    2011-01-01

    A substantial amount of research has suggested that adolescents' attitudes and behaviors are influenced by peers; however, little is known regarding adolescents' individual variability, or susceptibility, to peer influence. In this study, a performance-based index from an experimental paradigm was used to directly measure adolescents'…

  5. Effect of molecule-particle binding on the reduction in the mixed-frequency alternating current magnetic susceptibility of magnetic bio-reagents

    NASA Astrophysics Data System (ADS)

    Yang, C. C.; Yang, S. Y.; Chen, H. H.; Weng, W. L.; Horng, H. E.; Chieh, J. J.; Hong, C. Y.; Yang, H. C.

    2012-07-01

    By specifically bio-functionalizing magnetic nanoparticles, magnetic nanoparticles are able to label target bio-molecules. This property can be applied to quantitatively detect molecules invitro by measuring the related magnetic signals of nanoparticles bound with target molecules. One of the magnetic signals is the reduction in the mixed-frequency ac magnetic susceptibility of suspended magnetic nanoparticles due to the molecule-particle association. Many experimental results show empirically that the molecular-concentration dependent reduction in ac magnetic susceptibility follows the logistic function. In this study, it has been demonstrated that the logistic behavior is originated from the growth of particle sizes due to the molecule-particle association. The analytic relationship between the growth of particle sizes and the reduction in ac magnetic susceptibility is developed.

  6. Vortex flux dynamics and harmonic ac magnetic response of Ba(Fe0.94Ni0.06)2As2 bulk superconductor

    DOE PAGES

    Nikolo, Martin; Zapf, Vivien S.; Singleton, John; ...

    2016-07-22

    Vortex dynamics and nonlinear ac response are studied in a Ba(Fe0.94Ni0.06)2As2(Tc= 18.5 K) bulk superconductor in magnetic fields up to 12 T via ac susceptibility measurements of the first ten harmonics. A comprehensive study of the ac magnetic susceptibility and its first ten harmonics finds shifts to higher temperatures with increasing ac measurement frequencies (10 to 10,000 Hz) for a wide range of ac (1, 5, and 10 Oe) and dc fields (0 to 12 T). The characteristic measurement time constant t1 is extracted from the exponential fit of the data and linked to vortex relaxation. The Anderson-Kim Arrhenius lawmore » is applied to determine flux activation energy Ea/k as a function dc magnetic field. The de-pinning, or irreversibility lines, were determined by a variety of methods and extensively mapped. The ac response shows surprisingly weak higher harmonic components, suggesting weak nonlinear behavior. Lastly, our data does not support the Fisher model; we do not see an abrupt vortex glass to vortex liquid transition and the resistivity does not drop to zero, although it appears to approach zero exponentially.« less

  7. Susceptibility Testing by Polymerase Chain Reaction DNA Quantitation: A Method to Measure Drug Resistance of Human Immunodeficiency Virus Type 1 Isolates

    NASA Astrophysics Data System (ADS)

    Eron, Joseph J.; Gorczyca, Paul; Kaplan, Joan C.; D'Aquila, Richard T.

    1992-04-01

    Polymerase chain reaction (PCR) DNA quantitation (PDQ) susceptibility testing rapidly and directly measures nucleoside sensitivity of human immunodeficiency virus type 1 (HIV-1) isolates. PCR is used to quantitate the amount of HIV-1 DNA synthesized after in vitro infection of peripheral blood mononuclear cells. The relative amounts of HIV-1 DNA in cell lysates from cultures maintained at different drug concentrations reflect drug inhibition of virus replication. The results of PDQ susceptibility testing of 2- or 3-day cultures are supported by assays measuring HIV-1 p24 antigen production in supernatants of 7- or 10-day cultures. DNA sequence analyses to identify mutations in the reverse transcriptase gene that cause resistance to 3'-azido-3'-deoxythymidine also support the PDQ results. With the PDQ method, both infectivity titration and susceptibility testing can be performed on supernatants from primary cultures of peripheral blood mononuclear cells. PDQ susceptibility testing should facilitate epidemiologic studies of the clinical significance of drug-resistant HIV-1 isolates.

  8. Assessment of the E-Selectin rs5361 (561A>C) Polymorphism and Soluble Protein Concentration in Acute Coronary Syndrome: Association with Circulating Levels

    PubMed Central

    Sandoval-Pinto, Elena; Ramon Padilla-Gutiérrez, Jorge; Valdes-Alvarado, Emmanuel; Janet García-González, Ilian; Valdez-Haro, Angelica; Francisco Muñoz-Valle, Jose; Enrique Flores-Salinas, Hector; Rivas, Fernando; Valle, Yeminia

    2014-01-01

    Introduction. The acute coronary syndrome (ACS) is a complex disease where genetic and environmental factors are involved. E-selectin gene is a candidate for ACS progression due to its contribution in the inflammatory process and endothelial function. The rs5361 (561A>C) polymorphism in the E-selectin gene has been linked to changes in gene expression, affinity for its receptor, and plasmatic levels; therefore it is associated with an increased risk of cardiovascular disease. The aim of this study was to determine the association of the rs5361 polymorphism with ACS and to measure serum levels of soluble E-selectin (sE-selectin). Materials and Methods. 283 ACS patients and 205 healthy subjects (HS) from Western Mexico were included. The polymerase chain reaction-restriction fragment length polymorphism was used to determine the rs5361 polymorphism. The sE-selectin levels were measured by enzyme-linked immunosorbent assay. Results. Neither genotype nor allele frequencies of the rs5361 polymorphism showed statistical differences between groups. The sE-selectin levels were significantly higher in ACS patients compared to HS (54.58 versus 40.41 ng/ml, P = 0.02). The C allele had no effect on sE-selectin levels. Conclusions. The rs5361 E-selectin gene polymorphism is not a susceptibility marker for ACS in Western Mexico population. However, sE-selectin may be a biological marker of ACS. PMID:25147432

  9. Specific absorption rate dependence on temperature in magnetic field hyperthermia measured by dynamic hysteresis losses (ac magnetometry).

    PubMed

    Garaio, Eneko; Sandre, Olivier; Collantes, Juan-Mari; Garcia, Jose Angel; Mornet, Stéphane; Plazaola, Fernando

    2015-01-09

    Magnetic nanoparticles (NPs) are intensively studied for their potential use for magnetic hyperthermia, a treatment that has passed a phase II clinical trial against severe brain cancer (glioblastoma) at the end of 2011. Their heating power, characterized by the 'specific absorption rate (SAR)', is often considered temperature independent in the literature, mainly because of the difficulties that arise from the measurement methodology. Using a dynamic magnetometer presented in a recent paper, we measure here the thermal dependence of SAR for superparamagnetic iron oxide (maghemite) NPs of four different size-ranges corresponding to mean diameters around 12 nm, 14 nm, 15 nm and 16 nm. The article reports a parametrical study extending from 10 to 60 °C in temperature, from 75 to 1031 kHz in frequency, and from 2 to 24 kA m(-1) in magnetic field strength. It was observed that SAR values of smaller NPs decrease with temperature whereas for the larger sample (16 nm) SAR values increase with temperature. The measured variation of SAR with temperature is frequency dependent. This behaviour is fully explained within the scope of linear response theory based on Néel and Brown relaxation processes, using independent magnetic measurements of the specific magnetization and the magnetic anisotropy constant. A good quantitative agreement between experimental values and theoretical values is confirmed in a tri-dimensional space that uses as coordinates the field strength, the frequency and the temperature.

  10. Specific absorption rate dependence on temperature in magnetic field hyperthermia measured by dynamic hysteresis losses (ac magnetometry)

    NASA Astrophysics Data System (ADS)

    Garaio, Eneko; Sandre, Olivier; Collantes, Juan-Mari; Garcia, Jose Angel; Mornet, Stéphane; Plazaola, Fernando

    2015-01-01

    Magnetic nanoparticles (NPs) are intensively studied for their potential use for magnetic hyperthermia, a treatment that has passed a phase II clinical trial against severe brain cancer (glioblastoma) at the end of 2011. Their heating power, characterized by the ‘specific absorption rate (SAR)’, is often considered temperature independent in the literature, mainly because of the difficulties that arise from the measurement methodology. Using a dynamic magnetometer presented in a recent paper, we measure here the thermal dependence of SAR for superparamagnetic iron oxide (maghemite) NPs of four different size-ranges corresponding to mean diameters around 12 nm, 14 nm, 15 nm and 16 nm. The article reports a parametrical study extending from 10 to 60 {}^\\circ C in temperature, from 75 to 1031 kHz in frequency, and from 2 to 24 kA m-1 in magnetic field strength. It was observed that SAR values of smaller NPs decrease with temperature whereas for the larger sample (16 nm) SAR values increase with temperature. The measured variation of SAR with temperature is frequency dependent. This behaviour is fully explained within the scope of linear response theory based on Néel and Brown relaxation processes, using independent magnetic measurements of the specific magnetization and the magnetic anisotropy constant. A good quantitative agreement between experimental values and theoretical values is confirmed in a tri-dimensional space that uses as coordinates the field strength, the frequency and the temperature.

  11. Use of Zn concentration in the gastrointestinal tract as a measure of phytate susceptibility to the effect of phytase supplementation in broilers.

    PubMed

    Morgan, N K; Scholey, D V; Burton, E J

    2016-10-27

    Zinc (Zn) is the most vulnerable cation to complexation with phytate. An experiment was conducted to evaluate the potential of measurements of Zn concentration in the gastrointestinal tract as a marker to assess the anti-nutritional impact of phytate and susceptibility of phytate to phytase in broilers. Ross 308 broilers (n = 180) were fed one of 5 experimental diets with differing phytase activity levels, analyzed at 605, 1150, 1804, 3954, and 5925 U/kg. Broiler performance and Zn concentration, pH, and amount of phytate hydrolyzed in the gizzard, duodenum, and ileum were analyzed at d 21 post hatch. Phytate susceptibility to phytase degradation was determined in vivo and in vitro by measuring total phytate-P hydrolyzed in the tract or in conditions that mimicked the tract, respectively. Phytase activity level had a significant (P < 0.05) impact on Zn concentration and phytate hydrolyzed in the gizzard and ileum, but not in the duodenum. Strong relationships were observed between the amount of phytate hydrolyzed and Zn concentration in the gizzard in birds fed the diets with 1804 U/kg or higher levels of phytase. Phytate and phytase effects could therefore potentially be evaluated by measuring Zn concentration in the gizzard. Susceptible phytate levels measured in vivo and in vitro were almost identical in the diet with phytase activity of 5925 U/kg, but in the diets with lower phytase activity levels the in vitro assay overestimated the amount of P released. There were strong relationships between in vivo susceptible phytate level and pH and amount of phytate hydrolyzed in the gizzard, duodenum, and ileum and Zn concentration in the gizzard and ileum. This illustrates that phytate susceptibility directly effects mineral availability in the gastrointestinal tract. Measurements of Zn concentration in the gastrointestinal tract, particularly in the gizzard, can potentially be used as a marker to assess the anti-nutritional impact of phytate and susceptibility

  12. NONLINEAR DIAGNOSTICS USING AC DIPOLES.

    SciTech Connect

    PEGGS,S.

    1999-03-29

    There are three goals in the accurate nonlinear diagnosis of a storage ring. First, the beam must be moved to amplitudes many times the natural beam size. Second, strong and long lasting signals must be generated. Third, the measurement technique should be non-destructive. Conventionally, a single turn kick moves the beam to large amplitudes, and turn-by-turn data are recorded from multiple beam position monitors (BPMs) [1-6]. Unfortunately, tune spread across the beam causes the center of charge beam signal to ''decohere'' on a time scale often less than 100 turns. Filamentation also permanently destroys the beam emittance (in a hadron ring). Thus, the ''strong single turn kick'' technique successfully achieves only one out of the three goals. AC dipole techniques can achieve all three. Adiabatically excited AC dipoles slowly move the beam out to large amplitudes. The coherent signals then recorded last arbitrarily long. The beam maintains its original emittance if the AC dipoles are also turned off adiabatically, ready for further use. The AGS already uses an RF dipole to accelerate polarized proton beams through depolarizing resonances with minimal polarization loss [7]. Similar AC dipoles will be installed in the horizontal and vertical planes of both rings in RHIC [8]. The RHIC AC dipoles will also be used as spin flippers, and to measure linear optical functions [9].

  13. Core loss and magnetic susceptibility of superparamagnetic Fe nanoparticle assembly

    NASA Astrophysics Data System (ADS)

    Kin, Masane; Kura, Hiroaki; Ogawa, Tomoyuki

    2016-12-01

    Toroidal-shaped high-density Fe nanoparticle assemblies (FNAs) were fabricated by molding different sized Fe nanoparticles (NPs), and the effect of the magnetic behavior of the FNAs on the core loss and the magnetic susceptibility was investigated. An FNA with 4.3 nm diameter Fe NPs exhibits superparamagnetism at room temperature while an FNA with 6.4 nm diameter Fe NPs doesn't exhibit superparamagnetism at room temperature. AC magnetization curves at 1, 10 and 100 kHz were measured to evaluate the core loss of the toroidal-shaped FNAs. Both FNAs exhibited no significant eddy current loss, which suggests that surfactants on the NP surface effectively act to electrically insulate the NPs, and the NPs are not sintered together when the FNAs are molded. The AC magnetization curves had no hysteresis for the FNA with 4.3 nm diameter Fe NPs, i.e., the core loss was minimal for the superparamagnetic FNA. The magnetic susceptibility of the superparamagnetic FNA with 4.3 nm Fe NPs was 12 times higher than that estimated from Langevin theory due to the effect of strong magnetic dipole interaction. These results suggest that the superparamagnetic FNA has potential as a magnetic core material that exhibits low core loss and high magnetic susceptibility, even at high frequency.

  14. Measuring the magnetic-field-dependent chemical potential of a low-density three-dimensional electron gas in n -GaAs and extracting its magnetic susceptibility

    NASA Astrophysics Data System (ADS)

    Roy Choudhury, Aditya N.; Venkataraman, V.

    2016-01-01

    We report the magnetic-field-dependent shift of the electron chemical potential in bulk, n -type GaAs at room temperature. A transient voltage of ˜100 μ V was measured across a Au-Al2O3 -GaAs metal-oxide-semiconductor capacitor in a pulsed magnetic field of ˜6 T . Several spurious voltages larger than the signal that had plagued earlier researchers performing similar experiments were carefully eliminated. The itinerant magnetic susceptibility of GaAs is extracted from the experimentally measured data for four different doping densities, including one as low as 5 ×1015cm-3 . Though the susceptibility in GaAs is dominated by Landau-Peierls diamagnetism, the experimental technique demonstrated can be a powerful tool for extracting the total free carrier magnetization of any electron system. The method is also virtually independent of the carrier concentration and is expected to work better in the nondegenerate limit. Such experiments had been successfully performed in two-dimensional electron gases at cryogenic temperatures. However, an unambiguous report on having observed this effect in any three-dimensional electron gas has been lacking. We highlight the 50 year old literature of various trials and discuss the key details of our experiment that were essential for its success. The technique can be used to unambiguously yield only the itinerant part of the magnetic susceptibility of complex materials such as magnetic semiconductors and hexaborides, and thus shed light on the origin of ferromagnetism in such systems.

  15. Haematite natural crystals: non-linear initial susceptibility at low temperature

    NASA Astrophysics Data System (ADS)

    Guerrero-Suarez, S.; Martín-Hernández, F.

    2016-06-01

    Several works have reported that haematite has non-linear initial susceptibility at room temperature, like pyrrhotite or titanomagnetite, but there is no explanation for the observed behaviours yet. This study sets out to determine which physical property (grain size, foreign cations content and domain walls displacements) controls the initial susceptibility. The performed measurements include microprobe analysis to determine magnetic phases different to haematite; initial susceptibility (300 K); hysteresis loops, SIRM and backfield curves at 77 and 300 K to calculate magnetic parameters and minor loops at 77 K, to analyse initial susceptibility and magnetization behaviours below Morin transition. The magnetic moment study at low temperature is completed with measurements of zero field cooled-field cooled and AC susceptibility in a range from 5 to 300 K. The minor loops show that the non-linearity of initial susceptibility is closely related to Barkhausen jumps. Because of initial magnetic susceptibility is controlled by domain structure it is difficult to establish a mathematical model to separate magnetic subfabrics in haematite-bearing rocks.

  16. Vortex flux dynamics and harmonic ac magnetic response of Ba(Fe0.94Ni0.06)2As2 bulk superconductor

    SciTech Connect

    Nikolo, Martin; Zapf, Vivien S.; Singleton, John; Jiang, Jianyi; Weiss, Jeremy D.; Hellstrom, Eric E.

    2016-07-22

    Vortex dynamics and nonlinear ac response are studied in a Ba(Fe0.94Ni0.06)2As2(Tc= 18.5 K) bulk superconductor in magnetic fields up to 12 T via ac susceptibility measurements of the first ten harmonics. A comprehensive study of the ac magnetic susceptibility and its first ten harmonics finds shifts to higher temperatures with increasing ac measurement frequencies (10 to 10,000 Hz) for a wide range of ac (1, 5, and 10 Oe) and dc fields (0 to 12 T). The characteristic measurement time constant t1 is extracted from the exponential fit of the data and linked to vortex relaxation. The Anderson-Kim Arrhenius law is applied to determine flux activation energy Ea/k as a function dc magnetic field. The de-pinning, or irreversibility lines, were determined by a variety of methods and extensively mapped. The ac response shows surprisingly weak higher harmonic components, suggesting weak nonlinear behavior. Lastly, our data does not support the Fisher model; we do not see an abrupt vortex glass to vortex liquid transition and the resistivity does not drop to zero, although it appears to approach zero exponentially.

  17. Digital ac monitor

    DOEpatents

    Hart, George W.; Kern, Jr., Edward C.

    1987-06-09

    An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer.

  18. Digital ac monitor

    DOEpatents

    Hart, G.W.; Kern, E.C. Jr.

    1987-06-09

    An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer. 24 figs.

  19. ACS: ALMA Common Software

    NASA Astrophysics Data System (ADS)

    Chiozzi, Gianluca; Šekoranja, Matej

    2013-02-01

    ALMA Common Software (ACS) provides a software infrastructure common to all ALMA partners and consists of a documented collection of common patterns and components which implement those patterns. The heart of ACS is based on a distributed Component-Container model, with ACS Components implemented as CORBA objects in any of the supported programming languages. ACS provides common CORBA-based services such as logging, error and alarm management, configuration database and lifecycle management. Although designed for ALMA, ACS can and is being used in other control systems and distributed software projects, since it implements proven design patterns using state of the art, reliable technology. It also allows, through the use of well-known standard constructs and components, that other team members whom are not authors of ACS easily understand the architecture of software modules, making maintenance affordable even on a very large project.

  20. Induced Magnetization of Magnetite-titanomagnetite in Alternating Fields Ranging from 400 A/m to 80,000 A/m; Low-field Susceptibility (100 400 A/m) and Beyond

    NASA Astrophysics Data System (ADS)

    Borradaile, Graham J.; Stupavsky, Mike; Metsaranta, Dawn-Ann

    2008-07-01

    For remanence-bearing minerals (RBM) such as magnetite-titanomagnetite, susceptibility to induced magnetism ( M) measured in alternating fields ( H AC ) is field-dependent. However, for fields ≤ 400 A/m, measured in an AC induction coil instrument (at 19,100 Hz), susceptibility k 0 = M/H AC is sufficiently linear to provide a reproducible rock (or mineral) magnetic characteristic and its anisotropy may be related to arrangements of minerals in rock, or for single mineral grains to their crystalline or shape anisotropy. For any remanence-bearing mineral at higher fields k HF (= M/H AC ) is not constant and the term susceptibility is not normally used. This study bridges the responses between traditional low-field susceptibility measurements and those due to high applied fields, for example when studying hysteresis or saturation magnetization of RBM. Where | k HF | is measured in alternating fields that peak significantly above 400 A/m the M(H AC ) relation is forced to follow a hysteresis loop in which | k HF | > k 0 for small | H AC | and where | k HF | decreases to zero for very large fields that achieve saturation magnetization. Hysteresis nonlinearity is due to remanence acquired with one field direction requiring a reverse field for its cancellation. We investigate the transition from initial, traditional “low-field” susceptibility ( k 0 ) measurements at 60 A/m, through 24 different fields from 400 A/m to 40,000 A/m (for very high k 0 to 80,000 A/m). This reveals M(H AC ) dependence beyond from conventional k 0 through the range of hysteresis behavior in fields equal to and exceeding that required to achieve saturation magnetization ( M S ). We show k HF increases with peak H AC until the peak field is slightly less than saturation magnetization in natural rock samples rich in magnetite (TM0 = Fe3O4) and TM60 (Fe2.4Ti0.6O4). All sample suites predominantly contain multidomain grains with subordinate pseudo-single domain and single-domain grains. k/k 0

  1. A comparison of hepatitis A and hepatitis B measures among vaccinated and susceptible online men who have sex with men.

    PubMed

    Gilbert, L K; Levandowski, B A; Scanlon, K E; Peterson, R S

    2010-06-01

    Hepatitis A virus (HAV) and hepatitis B virus (HBV) continue to be major health concerns among men who have sex with men (MSM). The Internet both facilitates high-risk sexual encounters and provides opportunities for promoting healthy behaviours. This study compared self-reported HAV and HBV vaccination levels, based on demographics, health characteristics, hepatitis knowledge, attitudes and risk behaviours among MSM using an online survey posted from February through June 2005. Each participant (n = 968) reported whether they were vaccinated, infected or susceptible for hepatitis A and/or for hepatitis B. Men whose health-care provider recommended vaccination were 12.91 (95% confidence interval [CI] 8.11, 20.55) times more likely to be vaccinated against HAV and 17.93 (95% CI 10.82, 29.70) times more likely to be vaccinated against HBV than those at risk of infection, respectively. These data provide essential information for public health professionals to successfully promote vaccination among members of this population.

  2. Gap junction structures. V. Structural chemistry inferred from X-ray diffraction measurements on sucrose accessibility and trypsin susceptibility.

    PubMed

    Makowski, L; Caspar, D L; Phillips, W C; Goodenough, D A

    1984-04-15

    X-ray diffraction patterns have been recorded from partially oriented specimens of gap junctions isolated from mouse liver and suspended in sucrose solutions of different concentration and thus of different electron density. Analysis of these diffraction patterns has shown that sucrose is excluded from the 6-fold rotation axis of the junction lattice for a length of about 100 A. This indicates that the aqueous channel of the junctions is in the closed, high resistance state in these preparations. Mapping of the sucrose-accessible space in the junction indicates that the cross-sectional area of the channel entrance on the cytoplasmic side of the membrane could be up to five times larger than the area of the transmembrane channel. Sucrose does not penetrate more than 20 A into the membrane along the channel. Apparently the aqueous channel, 8 to 10 A in radius for most of its length, is narrowed or blocked by a small feature about 50 A from the center of the gap. Very close interactions exist between the gap junction protein and the lipid polar head groups on the cytoplasmic surface of the membrane. In this region, the protein intercalates between the polar head groups. These results suggest that the gap junction protein may have a functional two-domain structure. One domain, with a molecular weight of about 15,000, spans one bilayer and half of the gap and is contained largely within a radius of 25 A from the 6-fold axis. The second domain is smaller and occupies the cytoplasmic surface of the gap junction membrane. Trypsin digestion removes about 4000 Mr from the cytoplasmic surface domain of the junction protein. Most of the material susceptible to trypsin digestion is located more than 28 A from the 6-fold axis.

  3. Network susceptibilities: Theory and applications.

    PubMed

    Manik, Debsankha; Rohden, Martin; Ronellenfitsch, Henrik; Zhang, Xiaozhu; Hallerberg, Sarah; Witthaut, Dirk; Timme, Marc

    2017-01-01

    We introduce the concept of network susceptibilities quantifying the response of the collective dynamics of a network to small parameter changes. We distinguish two types of susceptibilities: vertex susceptibilities and edge susceptibilities, measuring the responses due to changes in the properties of units and their interactions, respectively. We derive explicit forms of network susceptibilities for oscillator networks close to steady states and offer example applications for Kuramoto-type phase-oscillator models, power grid models, and generic flow models. Focusing on the role of the network topology implies that these ideas can be easily generalized to other types of networks, in particular those characterizing flow, transport, or spreading phenomena. The concept of network susceptibilities is broadly applicable and may straightforwardly be transferred to all settings where networks responses of the collective dynamics to topological changes are essential.

  4. Network susceptibilities: Theory and applications

    NASA Astrophysics Data System (ADS)

    Manik, Debsankha; Rohden, Martin; Ronellenfitsch, Henrik; Zhang, Xiaozhu; Hallerberg, Sarah; Witthaut, Dirk; Timme, Marc

    2017-01-01

    We introduce the concept of network susceptibilities quantifying the response of the collective dynamics of a network to small parameter changes. We distinguish two types of susceptibilities: vertex susceptibilities and edge susceptibilities, measuring the responses due to changes in the properties of units and their interactions, respectively. We derive explicit forms of network susceptibilities for oscillator networks close to steady states and offer example applications for Kuramoto-type phase-oscillator models, power grid models, and generic flow models. Focusing on the role of the network topology implies that these ideas can be easily generalized to other types of networks, in particular those characterizing flow, transport, or spreading phenomena. The concept of network susceptibilities is broadly applicable and may straightforwardly be transferred to all settings where networks responses of the collective dynamics to topological changes are essential.

  5. Classroom Seating and Hypnotic Susceptibility.

    ERIC Educational Resources Information Center

    Sackeim, Harold A.; And Others

    1979-01-01

    The purpose of this study was to examine whether people who differ in behavioral and self-report measures of lateralized seating preferences also differ in hypnotic susceptibility. Only right-handed subjects were used, and the associations between hypnotic susceptibility and seating preference were examined separately for males and females.…

  6. Dynamic Properties of Dielectric Susceptibility in Ferroelectric Thin Films

    NASA Astrophysics Data System (ADS)

    Cui, Lian; Cui, Haiying; Wu, Chunmei; Yang, Guihua; He, Zelong; Wang, Yuling; Che, Jixin

    2016-02-01

    In this paper, frequency, temperature, film thickness, surface effects, and various parameters dependence of dielectric susceptibility is investigated theoretically for ferroelectric thin films by the modified Landau theory under an AC applied field. The dielectric susceptibility versus AC applied field shows butterfly-shaped behavior, and depends strongly on the frequency and amplitude of the field and temperature. Our study shows that the existence of the surface transition layer can depress the dielectric susceptibility of a ferroelectric thin film. These results are well consistent with the phenomena reported in experiments.

  7. Differential effect of severe and moderate social stress on blood immune and endocrine measures and susceptibility to collagen type II arthritis in male rats.

    PubMed

    Stefanski, Volker; Hemschemeier, Susanne K; Schunke, Kerstin; Hahnel, Anja; Wolff, Christine; Straub, Rainer H

    2013-03-01

    The effects of social stress on several blood immune measures and collagen-induced arthritis (CIA) were investigated in Wistar rats using the resident-intruder confrontation paradigm to induce stress of different intensity. Male intruders were exposed for one week to a dominant opponent either repeatedly for 4h daily (moderate stress) or continuously (severe stress). Arthritis was induced by intradermal injection of collagen type II (CII) into the tail skin at the end of day 3 of confrontation. Only severe stress was associated with decreased CD4 and CD8 T cells, and the increase in granulocyte numbers and body mass loss was more pronounced under these conditions. Only severe stress reduced the susceptibility to arthritis by about 50%. Severity scores did not differ in the first five days after disease onset between all groups. Subsequent experiments focused on severely stressed rats indicated that disease progressed until day 10 only in control animals, but not in severely stressed males. Stressor exposure resulted in increased blood monocyte numbers, but these males failed to accumulate macrophages into the skin at the site of CII injection. High numbers of attacks experienced by intruders correlated with delayed disease onset in severely stressed rats. We hypothesize that severe stress persisting after disease induction exhibits beneficial effects on the susceptibility of CIA and propose that the specific endocrine and immunological profile associated with severe stress is an important factor for disease outcome--a factor which probably explains many of the conflicting data of previous stress studies on CIA.

  8. Superconductor coil geometry and ac losses

    NASA Technical Reports Server (NTRS)

    Pierce, T. V., Jr.; Zapata, R. N.

    1976-01-01

    An empirical relation is presented which allows simple computation of volume-averaged winding fields from central fields for coils of small rectangular cross sections. This relation suggests that, in certain applications, ac-loss minimization can be accomplished by use of low winding densities, provided that hysteresis losses are independent of winding density. The ac-loss measurements on coils wound of twisted multifilamentary composite superconductors show no significant dependence on ac losses on winding density, thus permitting the use of winding density as an independent design parameter in loss minimization.

  9. Liquid helium boil-off measurements of heat leakage from sinter-forged BSCCO current leads under DC and AC conditions

    NASA Astrophysics Data System (ADS)

    Cha, Y. S.; Niemann, R. C.; Hull, J. R.; Youngdahl, C. A.; Lanagan, M. T.; Nakade, M.; Hara, T.

    1995-06-01

    Liquid helium boil-off experiments are conducted to determine the heat leakage rate of a pair of BSCCO 2223 high-temperature superconductor current leads made by sinter forging. The experiments are carried out in both DC and AC conditions and with and without an intermediate heat intercept. Current ranges are from 0-500 A for DC tests and 0-1,000 A(sub rms) for AC tests. The leads are self-cooled. Results show that magnetic hysteresis (AC) losses for both the BSCCO leads and the low-temperature superconductor current jumper are small for the current range. It is shown that significant reduction in heat leakage rate (liquid helium boil-off rate) is realized by using the BSCCO superconductor leads. At 100 A, the heat leakage rate of the BSCCO/copper binary lead is approximately 29% of that of the conventional copper lead. Further reduction in liquid helium boil-off rate can be achieved by using an intermediate heat intercept. For example, at 500 K, the heat leakage rate of the BSCCO/copper binary lead is only 7% of that of the conventional copper lead when an intermediate heat intercept is used.

  10. Liquid helium boil-off measurements of heat leakage from sinter-forged BSCCO current leads under DC and AC conditions

    SciTech Connect

    Cha, Y.S.; Niemann, R.C.; Hull, J.R.; Youngdahl, C.A.; Lanagan, M.T.; Nakade, M.; Hara, T.

    1995-06-01

    Liquid helium boil-off experiments are conducted to determine the heat leakage rate of a pair of BSCCO 2223 high-temperature superconductor current leads made by sinter forging. The experiments are carried out in both DC and AC conditions and with and without an intermediate heat intercept. Current ranges are from 0-500 A for DC tests and 0-1,000 A{sub rms} for AC tests. The leads are self-cooled. Results show that magnetic hysteresis (AC) losses for both the BSCCO leads and the low-temperature superconductor current jumper are small for the current range. It is shown that significant reduction in heat leakage rate (liquid helium boil-off rate) is realized by using the BSCCO superconductor leads. At 100 A, the heat leakage rate of the BSCCO/copper binary lead is approximately 29% of that of the conventional copper lead. Further reduction in liquid helium boil-off rate can be achieved by using an intermediate heat intercept. For example, at 500 K, the heat leakage rate of the BSCCO/copper binary lead is only 7% of that of the conventional copper lead when an intermediate heat intercept is used.

  11. Regional and voxel-wise comparisons of blood flow measurements between dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) and arterial spin labeling (ASL) in brain tumors.

    PubMed

    White, Carissa M; Pope, Whitney B; Zaw, Taryar; Qiao, Joe; Naeini, Kourosh M; Lai, Albert; Nghiemphu, Phioanh L; Wang, J J; Cloughesy, Timothy F; Ellingson, Benjamin M

    2014-01-01

    The objective of the current study was to evaluate the regional and voxel-wise correlation between dynamic susceptibility contrast (DSC) and arterial spin labeling (ASL) perfusion magnetic resonance imaging (MRI) measurement of cerebral blood flow (CBF) in patients with brain tumors. Thirty patients with histologically verified brain tumors were evaluated in the current study. DSC-MRI was performed by first using a preload dose of gadolinium contrast, then collecting a dynamic image acquisition during a bolus of contrast, followed by posthoc contrast agent leakage correction. Pseudocontinuous ASL was collected using 30 pairs of tag and control acquisition using a 3-dimensional gradient-echo spin-echo (GRASE) acquisition. All images were registered to a high-resolution anatomical atlas. Average CBF measurements within regions of contrast-enhancement and T2 hyperintensity were evaluated between the two modalities. Additionally, voxel-wise correlation between CBF measurements obtained with DSC and ASL were assessed. Results demonstrated a positive linear correlation between DSC and ASL measurements of CBF when regional average values were compared; however, a statistically significant voxel-wise correlation was only observed in around 30-40% of patients. These results suggest DSC and ASL may provide regionally similar, but spatially different measurements of CBF.

  12. Evaluation of the mastascanelite image analysis system for measuring zones of inhibition in disc diffusion susceptibility tests.

    PubMed

    Clarke, R E H; Winstanley, T G; Ridgway, E J

    2003-01-01

    In this evaluation a mastascanelite image analysis system is compared with manual measurement of disc diffusion inhibition zones. Data for 213 diverse organisms and a total of 1679 organism/antibiotic combinations gave an overall correlation coefficient of 0.988. The mean difference between readings was +0.425 mm, with 95% confidence limits of +/-2.94 mm, and the majority of scanned zones (97.51%) fell within +/-3 mm of the manual measurement. The mastascanelite system forms part of a laboratory suite and was found to be objective, accurate and rapid, reading and interpreting each plate in less than a second. Interfacing to the laboratory computer system facilitated data handling and performance control.

  13. OP04QUANTITATIVE MEASUREMENT OF BLOOD FLOW IN PAEDIATRIC BRAIN TUMOURS - A COMPARATIVE STUDY OF DYNAMIC SUSCEPTIBILITY CONTRAST AND MULTI-TIMEPOINT ARTERIAL SPIN LABEL IMAGING

    PubMed Central

    Abernethy, L.J.; Vidyasagar, R.; Pizer, B.L.; Mallucci, C.L.; Avula, S.; Parkes, L.M.

    2014-01-01

    INTRODUCTION: Arterial spin labeling (ASL) is a MR technique that allows for noninvasive quantification of cerebral blood flow (CBF). This technique, predominately used in research, has seen significant technical developments in the last few years that have led to more clinical applications. Currently, the main MR method used to provide perfusion measures in brain tumours is dynamic susceptibility contrast (DSC). DSC traces the signal changes caused by the transit of a bolus of gadolinium contrast agent. ASL has the advantage of not requiring bolus injection of contrast. We have performed a comparative study of DSC and multi-timepoint ASL in paediatric brain tumours (PBT). METHOD: Data from a total of 19 PBT patients (mean age: 9 ± 5 years; 10 females, 9 males) were included in the analyses for this study. Data used were from first presentation scans performed before any surgical intervention. Comparisons of the quantitative measures of CBF and blood arrival time between the two techniques were carried out to test the feasibility of ASL to provide useful quantification measures of CBF in PBT. RESULTS: DSC measurements of tumour blood flow showed a significant decrease in flow in comparison with normal brain, but this is not seen with ASL. There was a strong correlation between ASL and DSC measures of blood flow in normal brain (r = 0.65, p = 0.009), but not in tumour blood flow (r = 0.33, p = 0.2). CONCLUSION: This study demonstrates the feasibility and potential utility of ASL as a non-invasive technique for measuring blood flow in PBT. However, there is a discrepancy between ASL and DSC measures, that may be due to leakage of gadolinium contrast, reflecting the abnormal characteristics of tumour blood vessels in PBT.

  14. AC magnetohydrodynamic microfluidic switch

    SciTech Connect

    Lemoff, A V; Lee, A P

    2000-03-02

    A microfluidic switch has been demonstrated using an AC Magnetohydrodynamic (MHD) pumping mechanism in which the Lorentz force is used to pump an electrolytic solution. By integrating two AC MHD pumps into different arms of a Y-shaped fluidic circuit, flow can be switched between the two arms. This type of switch can be used to produce complex fluidic routing, which may have multiple applications in {micro}TAS.

  15. Sex-, morph- and size-specific susceptibility to stress measured by haematological variables in captive common wall lizard Podarcis muralis.

    PubMed

    Galeotti, Paolo; Pellitteri-Rosa, Daniele; Sacchi, Roberto; Gentilli, Augusto; Pupin, Fabio; Rubolini, Diego; Fasola, Mauro

    2010-12-01

    In polymorphic species of animals, colour morphs may show alternative physiological properties, and hence evolve or be maintained as an indirect response to selection exerted on these physiological attributes. In this study, we investigated if different colour morphs (white, red and yellow) of the polymorphic common wall lizard differed in their physiological responses to a long-term stress by determining variation between capture and release in leukocytes profiles, haemoparasite loads and body condition of male and females maintained in captivity throughout the breeding season. We found that most blood parameters of lizards varied significantly following captivity, and this variation was sex-, morph- and size-dependent. In particular, the heterophil:lymphocyte ratio (H:L), a sensitive measure of immunodepression and long-term stress, varied significantly among yellow females, larger individuals significantly increasing and smaller individuals decreasing their H:L ratio after captivity. This trend was reversed in red females, where smaller individuals presented raised H:L index at release. Our study indicated that response to long-term stressful conditions, such as those induced by captivity, differed among common wall lizard colour morphs, implying a sex-, size-(i.e. age) and morph-specific sensitivity to stress, and hence a different physiological profile of colour morphs, which may contribute to the maintenance of colour polymorphism in this species.

  16. Microtubule alignment and manipulation using AC electrokinetics.

    PubMed

    Uppalapati, Maruti; Huang, Ying-Ming; Jackson, Thomas N; Hancock, William O

    2008-09-01

    The kinesin-microtubule system plays an important role in intracellular transport and is a model system for integrating biomotor-driven transport into microengineered devices. AC electrokinetics provides a novel tool for manipulating and organizing microtubules in solution, enabling new experimental geometries for investigating and controlling the interactions of microtubules and microtubule motors in vitro. By fabricating microelectrodes on glass substrates and generating AC electric fields across solutions of microtubules in low-ionic-strength buffers, bundles of microtubules are collected and aligned and the electrical properties of microtubules in solution are measured. The AC electric fields result in electro-osmotic flow, electrothermal flow, and dielectrophoresis of microtubules, which can be controlled by varying the solution conductivity, AC frequency, and electrode geometry. By mapping the solution conductivity and AC frequency over which positive dielectrophoresis occurs, the apparent conductivity of taxol-stabilized bovine-brain microtubules in PIPES buffer is measured to be 250 mS m(-1). By maximizing dielectrophoretic forces and minimizing electro-osmotic and electrothermal flow, microtubules are assembled into opposed asters. These experiments demonstrate that AC electrokinetics provides a powerful new tool for kinesin-driven transport applications and for investigating the role of microtubule motors in development and maintenance of the mitotic spindle.

  17. Neuropsychological Test Performance and Hypnotic Susceptibility.

    ERIC Educational Resources Information Center

    Query, William T.; And Others

    1983-01-01

    Examined the relationship between brain-behavior and hypnotic susceptibility in 70 alcoholic patients, using the Stanford Hypnotic Susceptibility Scale and its Fromm-Weingarten modification. Results showed the two scales were interchangeable insofar as they measured the same ability, and indicated that hypnotic susceptibility is related to…

  18. Synergistic interactions between Cry1Ac and natural cotton defenses limit survival of Cry1Ac-resistant Helicoverpa zea (Lepidoptera: Noctuidae) on Bt cotton.

    PubMed

    Anilkumar, Konasale J; Sivasupramaniam, Sakuntala; Head, Graham; Orth, Robert; Van Santen, Edzard; Moar, William J

    2009-07-01

    Larvae of the bollworm Helicoverpa zea (Boddie) show some tolerance to Bacillus thuringiensis (Bt) Cry1Ac, and can survive on Cry1Ac-expressing Bt cotton, which should increase resistance development concerns. However, field-evolved resistance has not yet been observed. In a previous study, a population of H. zea was selected for stable resistance to Cry1Ac toxin. In the present study, we determined in laboratory bioassays if larvae of the Cry1Ac toxin-resistant H. zea population show higher survival rates on field-cultivated Bt cotton squares (= flower buds) collected prebloom-bloom than susceptible H. zea. Our results show that Cry1Ac toxin-resistant H. zea cannot complete larval development on Cry1Ac-expressing Bt cotton, despite being more than 150-fold resistant to Cry1Ac toxin and able to survive until pupation on Cry1Ac toxin concentrations greater than present in Bt cotton squares. Since mortality observed for Cry1Ac-resistant H. zea on Bt cotton was higher than expected, we investigated whether Cry1Ac interacts with gossypol and or other compounds offered with cotton powder in artificial diet. Diet incorporation bioassays were conducted with Cry1Ac toxin alone, and with gossypol and 4% cotton powder in the presence and absence of Cry1Ac. Cry1Ac toxin was significantly more lethal to susceptible H. zea than to resistant H. zea, but no difference in susceptibility to gossypol was observed between strains. However, combinations of Cry1Ac with gossypol or cotton powder were synergistic against resistant, but not against susceptible H. zea. Gossypol concentrations in individual larvae showed no significant differences between insect strains, or between larvae fed gossypol alone vs. those fed gossypol plus Cry1Ac. These results may help explain the inability of Cry1Ac-resistant H. zea to complete development on Bt cotton, and the absence of field-evolved resistance to Bt cotton by this pest.

  19. Quantitative measurement of blood flow in paediatric brain tumours—a comparative study of dynamic susceptibility contrast and multi time-point arterial spin labelled MRI

    PubMed Central

    Abernethy, Laurence; Pizer, Barry; Avula, Shivaram; Parkes, Laura M

    2016-01-01

    Objective: Arterial spin-labelling (ASL) MRI uses intrinsic blood water to quantify the cerebral blood flow (CBF), removing the need for the injection of a gadolinium-based contrast agent used for conventional perfusion imaging such as dynamic susceptibility contrast (DSC). Owing to the non-invasive nature of the technique, ASL is an attractive option for use in paediatric patients. This work compared DSC and multi-timepoint ASL measures of CBF in paediatric brain tumours. Methods: Patients (n = 23; 20 low-grade tumours and 3 high-grade tumours) had DSC and multi-timepoint ASL with and without vascular crushers (VC). VC removes the contribution from larger vessel blood flow. Mean perfusion metrics were extracted from control and T1-enhanced tumour regions of interest (ROIs): arterial arrival time (AAT) and CBF from the ASL images with and without VC, relative cerebral blood flow (rCBF), relative cerebral blood volume, delay time (DT) and mean transit time (MTT) from the DSC images. Results: Significant correlations existed for: AAT and DT (r = 0.77, p = 0.0002) and CBF and rCBF (r = 0.56, p = 0.02) in control ROIs for ASL-noVC. No significant correlations existed between DSC and ASL measures in the tumour region. Significant differences between control and tumour ROI were found for MTT (p < 0.001) and rCBF (p < 0.005) measures. Conclusion: Significant correlations between ASL-noVC and DSC measures in the normal brain suggest that DSC is most sensitive to macrovascular blood flow. The absence of significant correlations within the tumour ROI suggests that ASL is sensitive to different physiological mechanisms compared with DSC measures. Advances in knowledge: ASL provides information which is comparable with that of DSC in healthy tissues, but appears to reflect a different physiology in tumour tissues. PMID:26975495

  20. A case of time-dependent anisotropy of low-field susceptibility (AMS)

    NASA Astrophysics Data System (ADS)

    Borradaile, Graham J.; Geneviciene, Ieva

    2007-07-01

    A suite of non-tectonized, Meso-Proterozoic siliceous crystal tuffs and volcanic breccia with a visible stratification has a modal bulk susceptibility ( k) ˜ 160 μSI [mean; S.D. = 141 μSI; 44 μSI]. Normally, such susceptibilities suffice to make reliable measurements of anisotropy of low field susceptibility (AMS) using AC induction-coil instruments. However, for this suite, time-dependent susceptibility - variations during measurement are large in comparison to susceptibility - differences along different axes through a specimen. Thus, in many specimens, AMS axes determined by routine induction coil measurement in a (Sapphire Instruments SI2B; 19,200 Hz, 60 A/m) measurement procedures are not reproducible. The apparent variation of specimen susceptibility during a single, four minute AMS measurement can > 2 μSI whereas in the same interval the noise-level of our instrument is < 0.2 μSI. Thus, the time-dependence of the specimen-susceptibility is an intrinsic phenomenon due to the characteristics (grain size, domain structure) of the magnetite which dominates susceptibility during measurement and handling. Two procedures improved the reproducibility and stability of AMS axial orientations in some specimens. First, for some specimens, one or two cycles of LTD or AF demagnetization (≤ 15 mT) stabilized AMS axes. (Previous workers have observed that LTD and AF demagnetization may change slightly the AMS of polydomainal magnetite). Of course, exposure to alternating fields is preferably avoided before any AMS study. Second, for some specimens AMS measurement were improved by shielding the induction coil instrument in a large magnetically shielded space (ambient field < 5 nT). Further improvements were achieved by permitting the specimens to relax in side a magnetic shield for 24 h before measurement. The occurrence of time-dependent bulk susceptibility, especially noticeable in its AMS axial orientations is certainly a rare phenomenon and the procedures we used

  1. Improvement of immunoassay detection system by using alternating current magnetic susceptibility.

    PubMed

    Kawabata, R; Mizoguchi, T; Kandori, A

    2016-03-01

    A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.

  2. Improvement of immunoassay detection system by using alternating current magnetic susceptibility

    NASA Astrophysics Data System (ADS)

    Kawabata, R.; Mizoguchi, T.; Kandori, A.

    2016-03-01

    A major goal with this research was to develop a low-cost and highly sensitive immunoassay detection system by using alternating current (AC) magnetic susceptibility. We fabricated an improved prototype of our previously developed immunoassay detection system and evaluated its performance. The prototype continuously moved sample containers by using a magnetically shielded brushless motor, which passes between two anisotropic magneto resistance (AMR) sensors. These sensors detected the magnetic signal in the direction where each sample container passed them. We used the differential signal obtained from each AMR sensor's output to improve the signal-to-noise ratio (SNR) of the magnetic signal measurement. Biotin-conjugated polymer beads with avidin-coated magnetic particles were prepared to examine the calibration curve, which represents the relation between AC magnetic susceptibility change and polymer-bead concentration. For the calibration curve measurement, we, respectively, measured the magnetic signal caused by the magnetic particles by using each AMR sensor installed near the upper or lower part in the lateral position of the passing sample containers. As a result, the SNR of the prototype was 4.5 times better than that of our previous system. Moreover, the data obtained from each AMR sensor installed near the upper part in the lateral position of the passing sample containers exhibited an accurate calibration curve that represented good correlation between AC magnetic susceptibility change and polymer-bead concentration. The conclusion drawn from these findings is that our improved immunoassay detection system will enable a low-cost and highly sensitive immunoassay.

  3. AC losses in a HTS coil carrying DC current in AC external magnetic field

    NASA Astrophysics Data System (ADS)

    Ogawa, J.; Zushi, Y.; Fukushima, M.; Tsukamoto, O.; Suzuki, E.; Hirakawa, M.; Kikukawa, K.

    2003-10-01

    We electrically measured AC losses in a Bi2223/Ag-sheathed pancake coil excited by a DC current in AC external magnetic field. Losses in the coil contain two kinds of loss components that are the magnetization losses and dynamic resistance losses. In the measurement, current leads to supply a current to the coil were specially arranged to suppress electromagnetic coupling between the coil current and the AC external magnetic field. A double pick-up coils method was used to suppress a large inductive voltage component contained in voltage signal for measuring the magnetization losses. It was observed that the magnetization losses were dependent on the coil current and that a peak of a curve of the loss factor vs. amplitude of the AC external magnetic field shifted to lower amplitude of the AC magnetic field as the coil current increased. This result suggests the full penetration magnetic field of the coil tape decreases as the coil current increases. The dynamic resistance losses were measured by measuring a DC voltage appearing between the coil terminals. It was observed that the DC voltage appearing in the coil subject to the AC external magnetic field was much larger than that in the coil subject to DC magnetic field.

  4. Overview of quantitative susceptibility mapping.

    PubMed

    Deistung, Andreas; Schweser, Ferdinand; Reichenbach, Jürgen R

    2017-04-01

    Magnetic susceptibility describes the magnetizability of a material to an applied magnetic field and represents an important parameter in the field of MRI. With the recently introduced method of quantitative susceptibility mapping (QSM) and its conceptual extension to susceptibility tensor imaging (STI), the non-invasive assessment of this important physical quantity has become possible with MRI. Both methods solve the ill-posed inverse problem to determine the magnetic susceptibility from local magnetic fields. Whilst QSM allows the extraction of the spatial distribution of the bulk magnetic susceptibility from a single measurement, STI enables the quantification of magnetic susceptibility anisotropy, but requires multiple measurements with different orientations of the object relative to the main static magnetic field. In this review, we briefly recapitulate the fundamental theoretical foundation of QSM and STI, as well as computational strategies for the characterization of magnetic susceptibility with MRI phase data. In the second part, we provide an overview of current methodological and clinical applications of QSM with a focus on brain imaging. Copyright © 2016 John Wiley & Sons, Ltd.

  5. [Antimicrobial susceptibility in Chile 2012].

    PubMed

    Cifuentes-D, Marcela; Silva, Francisco; García, Patricia; Bello, Helia; Briceño, Isabel; Calvo-A, Mario; Labarca, Jaime

    2014-04-01

    Bacteria antimicrobial resistance is an uncontrolled public health problem that progressively increases its magnitude and complexity. The Grupo Colaborativo de Resistencia, formed by a join of experts that represent 39 Chilean health institutions has been concerned with bacteria antimicrobial susceptibility in our country since 2008. In this document we present in vitro bacterial susceptibility accumulated during year 2012 belonging to 28 national health institutions that represent about 36% of hospital discharges in Chile. We consider of major importance to report periodically bacteria susceptibility so to keep the medical community updated to achieve target the empirical antimicrobial therapies and the control measures and prevention of the dissemination of multiresistant strains.

  6. ACS CCDs daily monitor

    NASA Astrophysics Data System (ADS)

    Sirianni, Marco

    2006-07-01

    This program consists of a set of basic tests to monitor, the read noise, thedevelopment of hot pixels and test for any source of noise in ACS CCDdetectors. The files, biases and dark will be used to create referencefiles for science calibration. This programme will be for the entire lifetime of ACS.For cycle 15 the program will cover 18 months 12.1.06->05.31.08and it has been divied into three different proposal each covering six months.The three poroposal are 11041-11042-11043.

  7. ac bidirectional motor controller

    NASA Technical Reports Server (NTRS)

    Schreiner, K.

    1988-01-01

    Test data are presented and the design of a high-efficiency motor/generator controller at NASA-Lewis for use with the Space Station power system testbed is described. The bidirectional motor driver is a 20 kHz to variable frequency three-phase ac converter that operates from the high-frequency ac bus being designed for the Space Station. A zero-voltage-switching pulse-density-modulation technique is used in the converter to shape the low-frequency output waveform.

  8. Studies of vanadium-phosphorus-oxygen selective oxidation catalysts by sup 31 P and sup 51 V NMR spin-echo and volume susceptibility measurements

    SciTech Connect

    Li, Juan.

    1991-10-01

    The purpose of this work is to characterize the vanadium-phosphorous oxide (V-P-O) catalysts for the selective oxidation of n-butane and 1-butene to maleic anhydride. The utility of solid state nuclear magnetic resonance as an analytical tool in this investigation lies in its sensitivity to the electronic environment surrounding the phosphorous and vanadium nuclei, and proximity of paramagnetic species. Spin-echo mapping NMR of {sup 31}p and {sup 51}v and volume magnetic susceptibility measurements were used as local microscopic probes of the presence of V{sup 5+}, V{sup 4+}, V{sup 3+} species in the model compounds: {beta}-VOPO{sub 4}, {beta}-VOPO{sub 4} treated with n-butane/1-butene, (VO){sub 2}P{sub 2}O{sub 7} treated with n-butane/1-butene; and industrial catalysts with P/V (phosphorus to vanadium) ratio of 0.9, 1.0 and 1.1, before and after treatment with n-butane and 1-butene. The NMR spectra provide a picture of how the oxidation states of vanadium are distributed in these catalysts. 73 refs., 32 figs., 8 tabs.

  9. Magnetic susceptibility as a direct measure of oxidation state in LiFePO4 batteries and cyclic water gas shift reactors.

    PubMed

    Kadyk, Thomas; Eikerling, Michael

    2015-08-14

    The possibility of correlating the magnetic susceptibility to the oxidation state of the porous active mass in a chemical or electrochemical reactor was analyzed. The magnetic permeability was calculated using a hierarchical model of the reactor. This model was applied to two practical examples: LiFePO4 batteries, in which the oxidation state corresponds with the state-of-charge, and cyclic water gas shift reactors, in which the oxidation state corresponds to the depletion of the catalyst. In LiFePO4 batteries phase separation of the lithiated and delithiated phases in the LiFePO4 particles in the positive electrode gives rise to a hysteresis effect, i.e. the magnetic permeability depends on the history of the electrode. During fast charge or discharge, non-uniform lithium distributionin the electrode decreases the hysteresis effect. However, the overall sensitivity of the magnetic response to the state-of-charge lies in the range of 0.03%, which makes practical measurement challenging. In cyclic water gas shift reactors, the sensitivity is 4 orders of magnitude higher and without phase separation, no hysteresis occurs. This shows that the method is suitable for such reactors, in which large changes of the magnetic permeability of the active material occurs.

  10. Estimates of flow direction for calc-alkaline welded tuffs and paleomagnetic data reliability from anisotropy of magnetic susceptibility measurements: Central San Juan Mountains, southwest Colorado

    NASA Astrophysics Data System (ADS)

    Ellwood, Brooks B.

    1982-07-01

    Flow directions are estimated from the measurement of the magnetic fabric of 106 samples, collected at 18 sites in four welded tuff units in the central San Juan Mountains of southern Colorado. The estimates assume that the tuffs generally flowed directly away from the extrusive vents and that the lineations of magnetic grains within the tuffs represent the flow direction at individual sites. Errors in the estimation may arise from topographic variation, rheomorphism (post-emplacement mass flow) within the tuff, and other factors. Magnetic lineation is defined as the site mean anisotropy of magnetic susceptibility maximum azimuth. A test on the flow directions for individual units is based on the projection of lineation azimuths and their intersection within or near the known source caldera for the tuff. This test is positive for the four units examined. Paleomagnetic results for these tuffs are probably reliable indicators of the geomagnetic field direction in southwest Colorado, during the time (28.2-26.5 Ma) of emplacement.

  11. Frequency dependence of the absorption component of the magnetic susceptibility in superconducting Y1Ba2Cu3O7

    NASA Astrophysics Data System (ADS)

    Ducharme, S.; Durny, R.; Hautala, J.; Symko, O. G.; Taylor, P. C.

    Measurements of an apparent magnetic-field-dependent absorption (imaginary part of the a.c. magnetic susceptibility) in superconducting Y1Ba2Cu3O7 ceramics and crystals are reported. The absorption, which is observed over a wide range of frequencies but only when the material is below the superconducting transition temperature, is characterized by a narrow (about 30 Gauss FWHM at 6 MHz) peak and a wide (greater than 10 kG) feature, both of which are maximum at zero magnetic field. The absorption strength varies approximately as one over the square root of the frequency. The unusual magnetic-field-dependent peaks in the magnetic susceptibility are inherent in single grains and therefore do not originate from intergrain Josephson currents or multigrain (i.e., percolative) loops. The susceptibility peaks must be due to bulk behavior, interactions at grain surfaces, intragrain current loops, or intragrain Josephson junctions.

  12. AC/DC converter

    NASA Astrophysics Data System (ADS)

    Jain, Praveen K.

    1992-08-01

    In a system such as a 20 kHz space station primary electrical power distribution system, power conversion from AC to DC is required. Some of the basic requirements for this conversion are high efficiency, light weight and small volume, regulated output voltage, close to unity input power factor, distortionless input current, soft-starting, low electromagnetic interference, and high reliability. An AC-to-DC converter is disclosed which satisfies the main design objectives of such converters for use in space. The converter of the invention comprises an input transformer, a resonant network, a current controller, a diode rectifier, and an output filter. The input transformer is for connection to a single phase, high frequency, sinusoidal waveform AC voltage source and provides a matching voltage isolating from the AC source. The resonant network converts this voltage to a sinusoidal, high frequency bidirectional current output, which is received by the current controller to provide the desired output current. The diode rectifier is connected in parallel with the current controller to convert the bidirectional current into a unidirectional current output. The output filter is connected to the rectifier to provide an essentially ripple-free, substantially constant voltage DC output.

  13. AC/RF Superconductivity

    SciTech Connect

    Ciovati, Gianluigi

    2015-02-01

    This contribution provides a brief introduction to AC/RF superconductivity, with an emphasis on application to accelerators. The topics covered include the surface impedance of normal conductors and superconductors, the residual resistance, the field dependence of the surface resistance, and the superheating field.

  14. Two-component uniform spin susceptibility of superconducting HgBa2CuO4+δ single crystals measured using 63Cu and 199Hg nuclear magnetic resonance

    NASA Astrophysics Data System (ADS)

    Haase, Jürgen; Rybicki, Damian; Slichter, Charles P.; Greven, Martin; Yu, Guichuan; Li, Yuan; Zhao, Xudong

    2012-03-01

    63Cu and 199Hg nuclear magnetic resonance shifts for an optimally doped and underdoped HgBa2CuO4+δ single crystal are reported, and the temperature dependence dictates a two-component description of the uniform spin susceptibility. The first component, associated with the pseudogap phenomenon in the NMR shifts, decreases at room temperature and continues to drop as the temperature is lowered, without a drastic change at the transition temperature into the superconducting state. The second component is temperature independent above the superconducting transition temperature and vanishes rapidly below it. It is a substantial part of the total T-dependent susceptibility measured at both nuclei.

  15. Total AC losses in twisted and untwisted multifilamentary Bi-2223 superconducting tapes carrying AC transport current in AC longitudinal magnetic field

    NASA Astrophysics Data System (ADS)

    Amemiya, Naoyuki; Jin, Feng; Jiang, Zhenan; Shirai, Shunsuke; ten Haken, Bennie; Rabbers, Jan-Jaap; Ayai, Naoki; Hayashi, Kazuhiko

    2003-03-01

    In some electrical apparatuses, superconducting tapes are exposed to the longitudinal magnetic field. In this work, AC losses were measured in twisted and untwisted Bi-2223 tapes carrying AC transport current in the AC longitudinal magnetic field. In twisted tapes, the transport, magnetization and total losses depend on the relative direction of the longitudinal magnetic field to the direction of the transport current, while the field direction does not influence the AC loss characteristics in untwisted tapes. In the Z-twisted tapes, the total AC loss is larger in the longitudinal magnetic field that is anti-parallel to the transport current than in the longitudinal magnetic field of another direction. Numerical analysis shows that this field direction dependence of the total AC loss results from the change in the current distribution. In the longitudinal magnetic field that is anti-parallel to the transport current, the total AC loss in the Z-twisted tape is more than that in the untwisted tape. This dependence on the field direction is reversed in S-twisted tapes. It is to be noted that the twist increases the total AC loss in a longitudinal magnetic field of a certain direction, while it reduces the AC loss in the transverse magnetic field.

  16. Nutrition affects insect susceptibility to Bt toxins

    NASA Astrophysics Data System (ADS)

    Deans, Carrie A.; Behmer, Spencer T.; Tessnow, Ashley E.; Tamez-Guerra, Patricia; Pusztai-Carey, Marianne; Sword, Gregory A.

    2017-01-01

    Pesticide resistance represents a major challenge to global food production. The spread of resistance alleles is the primary explanation for observations of reduced pesticide efficacy over time, but the potential for gene-by-environment interactions (plasticity) to mediate susceptibility has largely been overlooked. Here we show that nutrition is an environmental factor that affects susceptibility to Bt toxins. Protein and carbohydrates are two key macronutrients for insect herbivores, and the polyphagous pest Helicoverpa zea self-selects and performs best on diets that are protein-biased relative to carbohydrates. Despite this, most Bt bioassays employ carbohydrate-biased rearing diets. This study explored the effect of diet protein-carbohydrate content on H. zea susceptibility to Cry1Ac, a common Bt endotoxin. We detected a 100-fold increase in LC50 for larvae on optimal versus carbohydrate-biased diets, and significant diet-mediated variation in survival and performance when challenged with Cry1Ac. Our results suggest that Bt resistance bioassays that use ecologically- and physiologically-mismatched diets over-estimate susceptibility and under-estimate resistance.

  17. Nutrition affects insect susceptibility to Bt toxins

    PubMed Central

    Deans, Carrie A.; Behmer, Spencer T.; Tessnow, Ashley E.; Tamez-Guerra, Patricia; Pusztai-Carey, Marianne; Sword, Gregory A.

    2017-01-01

    Pesticide resistance represents a major challenge to global food production. The spread of resistance alleles is the primary explanation for observations of reduced pesticide efficacy over time, but the potential for gene-by-environment interactions (plasticity) to mediate susceptibility has largely been overlooked. Here we show that nutrition is an environmental factor that affects susceptibility to Bt toxins. Protein and carbohydrates are two key macronutrients for insect herbivores, and the polyphagous pest Helicoverpa zea self-selects and performs best on diets that are protein-biased relative to carbohydrates. Despite this, most Bt bioassays employ carbohydrate-biased rearing diets. This study explored the effect of diet protein-carbohydrate content on H. zea susceptibility to Cry1Ac, a common Bt endotoxin. We detected a 100-fold increase in LC50 for larvae on optimal versus carbohydrate-biased diets, and significant diet-mediated variation in survival and performance when challenged with Cry1Ac. Our results suggest that Bt resistance bioassays that use ecologically- and physiologically-mismatched diets over-estimate susceptibility and under-estimate resistance. PMID:28045087

  18. Magnetic susceptibility of Inconel alloys 718, 625, and 600 at cryogenic temperatures

    NASA Technical Reports Server (NTRS)

    Goldberg, Ira B.; Mitchell, Michael R.; Murphy, Allan R.; Goldfarb, Ronald B.; Loughran, Robert J.

    1990-01-01

    After a hydrogen fuel bleed valve problem on the Discovery Space Shuttle was traced to the strong magnetization of Inconel 718 in the armature of the linear variable differential transformer near liquid hydrogen temperatures, the ac magnetic susceptibility of three samples of Inconel 718 of slightly different compositions, one sample of Inconel 625, and on sample of Inconel 600 were measured as a function of temperature. Inconel 718 alloys are found to exhibit a spin glass state below 16 K. Inconel 600 exhibits three different magnetic phases, the lowest-temperature state (below 6 K) being somewhat similar to that of Inconel 718. The magnetic states of the Inconel alloys and their magnetic susceptibilities appear to be strongly dependent on the exact composition of the alloy.

  19. Assessment of climatic and seismic cycles in southern chile from high resolution XRF and magnetic susceptibility measurements of historic lake sediments.

    NASA Astrophysics Data System (ADS)

    Boes, X.; Hubert-Ferrari, A.; Fagel, N.

    2006-12-01

    The high-resolution sedimentological studies performed on the sediment cores collected in the oceans or in the lakes constitutes the basis for inter-comparison of past climate variability. Among the new high-resolution approaches, the X-Ray Fluorescence (XRF) analysis of varved marine and lacustrine cores represents some of the best resolution. These data are particularly useful for tracking short-term climate changes expressed with calibrated time scales. However, the XRF results obtain on the fresh cores surface may be of low resolution because the core material is wet and unconsolidated. One particularly attractive method to solve this problem consists of impregnating the sediment cores with polymers in order to polish the core surface for XRF analyses. This step is essential for being able to get significant XRF and Magnetic Susceptibility (MS) results in the muddy cores. Since the 1960s, the evolution of sediment impregnation methods has been strongly linked to the development of innovative techniques (e.g., sampling devices, cryogenic and vacuum technologies, polymers, etc.). In this communication, we first propose a revised method that may be applied to prepare sediment cores for high-resolution XRF and MS data acquisition. Then we show an example of XRF and MS results obtain on laminated lake sediments from South America (Lago Puyehue, 40°S). As this area is very sensitive in terms of precipitation change (i.e., Southern Westerlies); the XRF data are compared with the regional instrumental precipitation database. The results are discussed in terms of climate and sismo- tectonic impacts over historic times. Our results shows that, in order to better interpret XRF tool over long sequences, the measurements should be first "calibrated" according to instrumental data such as precipitation, temperatures, and earthquake magnitudes.

  20. How can [Mo(IV)(CN)6](2-), an apparently octahedral (d)(2) complex, be diamagnetic? Insights from quantum chemical calculations and magnetic susceptibility measurements.

    PubMed

    Radoń, Mariusz; Rejmak, Paweł; Fitta, Magdalena; Bałanda, Maria; Szklarzewicz, Janusz

    2015-06-14

    Quantum chemical calculations are employed to elucidate the origin of a puzzling diamagnetism for a hexacyanomolybdate(IV) anion, [Mo(CN)6](2-), which was previously reported by Szklarzewicz et al. [Inorg. Chem., 2007, 46, 9531-9533]. The diamagnetism is surprising because for the octahedral (d)(2) complex one would rather expect a (paramagnetic) triplet ground state, clearly favored over a (diamagnetic) singlet state by an exchange interaction between two d electrons in the t2g orbitals. Nevertheless, the present calculations reveal that the minimum energy structure of isolated [Mo(CN)6](2-) is not an octahedron, but a trigonal prism; the latter geometry allows maximization of a σ-donation from the cyanides to the electron-deficient Mo(iv) center. Unlike for the octahedron, for the trigonal prism structure the singlet and triplet spin states are close in energy to within a few kcal mol(-1). Although the actual relative energy of the two spin states turns out to be method-dependent, the complete active space calculations (CASPT2; with the appropriate choice of the IPEA shift parameter) can reproduce the singlet ground state, in agreement with the experimentally observed diamagnetism. Moreover, magnetic measurements reveal a slight increase of the magnetic susceptibility with the increase of temperature from 100 to 300 K, suggesting an admixture of a thermally induced paramagnetism (possibly due to Boltzmann population of the low-energy triplet state) on top of the dominant diamagnetism. Our prediction that the geometry of [Mo(CN)6](2-) should significantly deviate from the ideal octahedron, not only in the gas phase, but also in a periodic DFT model of the crystalline phase, as well as the experimentally confirmed diamagnetic properties, does not agree with the previously reported ideal octahedral structure. We suggest that this crystal structure might have been determined incorrectly (e.g., due to overlooked merohedral twinning or superstructure properties) and

  1. Evaluation of modern IGBT-modules for hard-switched AC/DC/AC converters

    SciTech Connect

    Blaabjerg, F.; Pedersen, J.K.; Jaeger, U.

    1995-12-31

    The development of IGBT devices is still producing faster devices with lower losses. The applications become more advanced like a complete hard-switched AC/DC/AC converter with almost clean input current and regenerating capabilities. This paper will first focus on a detailed characterization and comparison of eight different IGBT-modules representing state-of-the-art for both PT and NPT technologies. The voltage level of the devices is 1,200V and 1,600V/1,700V. The characterization is done on an advanced measurement system which is briefly described. The characterization is based on static and dynamic tests for both IGBT and the diodes in the IGBT-modules at a junction temperature at 125 C. The comparison is first done directly based on conduction losses and switching losses, and later the measurements are used in a loss model for a complete AC/DC/AC converter application. In the AC/DC/AC converter the power losses are modelled, and different operating conditions are compared like different voltage levels in the DC-link. It is concluded dependent on operation conditions different devices will be preferable, but the high voltage devices have the highest losses even at a high operating voltage.

  2. Investigation of the electronic and structural properties of potassium hexaboride, KB6, by transport, magnetic susceptibility, EPR, and NMR measurements, temperature-dependent crystal structure determination, and electronic band structure calculations.

    PubMed

    Ammar, A; Ménétrier, M; Villesuzanne, A; Matar, S; Chevalier, B; Etourneau, J; Villeneuve, G; Rodríguez-Carvajal, J; Koo, H-J; Smirnov, A I; Whangbo, M-H

    2004-08-09

    The electronic and structural properties of potassium hexaboride, KB(6), were examined by transport, magnetic susceptibility, EPR, and NMR measurements, temperature-dependent crystal structure determination, and electronic band structure calculations. The valence bands of KB(6) are partially empty, but the electrical resistivity of KB(6) reveals that it is not a normal metal. The magnetic susceptibility as well as EPR and NMR measurements show the presence of localized electrons in KB(6). The EPR spectra of KB(6) have two peaks, a broad ( approximately 320 G) and a narrow (less than approximately 27 G) line width, and the temperature-dependence of the magnetic susceptibility of KB(6) exhibits a strong hysteresis below 70 K. The temperature-dependent crystal structure determination of KB(6) shows the occurrence of an unusual variation in the unit cell parameter hence supporting that the hysteresis of the magnetic susceptibility is a bulk phenomenon. The line width DeltaH(pp) of the broad EPR signal is independent of temperature and EPR frequency. This finding indicates that the line broadening results from the dipole-dipole interaction, and the spins responsible for the broad EPR peak has the average distance of approximately 1.0 nm. To explain these apparently puzzling properties, we examined a probable mechanism of electron localization in KB(6) and its implications.

  3. Diffusion Disk Susceptibility Testing with Cefaclor

    PubMed Central

    Shadomy, Smith; Carver, Melinda

    1978-01-01

    The reliability of the standardized 30-μg cephalothin disk and that of an experimental 30-μg cefaclor disk in predicting probable clinical susceptibility to cefaclor were compared. Quantitative determinations of cefaclor susceptibility were measured by the World Health Organization International Collaborative Study agar dilution procedure; diffusion disk tests were performed by the standardized U.S. Food and Drug Administration disk test. The cephalothin disk erred in predicting probable susceptibility in 52% of isolates of Enterococcus spp. resistant to 16 μg or less of cefaclor per ml; the cefaclor disk did not. The cephalothin disk erred in correctly predicting susceptibility in only 20% of cefaclor-susceptible isolates of Enterobacter spp.; the cefaclor disk correctly predicted susceptibility for 70%. These results indicate the need for further evaluation of a separate cefaclor disk for use in susceptibility testing with this new cephalosporin. PMID:646345

  4. AC response of 2H-NbSe2 single crystals with electron-irradiation-induced defects

    NASA Astrophysics Data System (ADS)

    Bartolomé, E.; Bartolomé, J.; Arauzo, A.; Eremenko, V. V.; Sirenko, V. A.

    2010-07-01

    The generation of defects in NbSe2 single crystals by electron irradiation has been investigated by a combination of ac susceptibility and structural measurements. Remarkably, thanks to the layered structure of NbSe2, we show that electronic irradiation cannot only create point defects but also in-plane extended defects, which modify anisotropically the ac response. Indeed, the analysis of the onset of the nonlinear susceptibility response, Hacl(T), as a function of irradiation dose and field orientation shows a correlated increase in the density of anisotropic defects induced by electron irradiation. Also, we measured a decrease in the strength of the pinning (Labusch) constant αL accounting for elastic vortex oscillations within the linear Campbell regime for high-dose-irradiated samples in a transverse field, again compatible with the presence of planar defects hindering vortex pinning. X-ray powder diffraction and TEM electron diffraction measurements suggest these in-plane defects may result from the rupture of Se-Se bonds and the formation of nanorods and nanowires by NbSe2 sheet rolling.

  5. AC Losses of Prototype HTS Transmission Cables

    SciTech Connect

    Demko, J.A.; Dresner, L.; Hughey, R.L.; Lue, J.W.; Olsen, S.K.; Sinha, U.; Tolbert, J.C.

    1998-09-13

    Since 1995 Southwire Company and Oak Ridge National Laboratory (ORNL) have jointly designed, built, and tested nine, l-m long, high temperature superconducting (HTS) transmission cable prototypes. This paper summarizes the AC loss measurements of five of the cables not reported elsewhere, and compares the losses with each other and with theory developed by Dresner. Losses were measured with both a calorimetric and an electrical technique. Because of the broad resistive transition of the HTS tapes, the cables can be operated stably beyond their critical currents. The AC losses were measured in this region as well as below critical currents. Dresner's theory takes into account the broad resistive transition of the HTS tapes and calculates the AC losses both below and above the critical current. The two sets of AC 10SS data agree with each other and with the theory quite welL In particular, at low currents of incomplete penetration, the loss data agree with the theoretical prediction of hysteresis loss based on only the outer two Iayers carrying the total current.

  6. Topological susceptibility from slabs

    NASA Astrophysics Data System (ADS)

    Bietenholz, Wolfgang; de Forcrand, Philippe; Gerber, Urs

    2015-12-01

    In quantum field theories with topological sectors, a non-perturbative quantity of interest is the topological susceptibility χ t. In principle it seems straightforward to measure χ t by means of Monte Carlo simulations. However, for local update algorithms and fine lattice spacings, this tends to be difficult, since the Monte Carlo history rarely changes the topological sector. Here we test a method to measure χ t even if data from only one sector are available. It is based on the topological charges in sub-volumes, which we denote as slabs. Assuming a Gaussian distribution of these charges, this method enables the evaluation of χ t, as we demonstrate with numerical results for non-linear σ-models.

  7. Magnetic susceptibility of topological nodal semimetals

    NASA Astrophysics Data System (ADS)

    Mikitik, G. P.; Sharlai, Yu. V.

    2016-11-01

    Magnetic susceptibility of the topological Weyl, type-II Weyl, Dirac, and line node semimetals is theoretically investigated. Dependences of this susceptibility on the chemical potential, temperature, direction, and magnitude of the magnetic field are found. The obtained results show that magnetic measurements can be very useful in investigating these semimetals. As an example, we calculate magnetic susceptibility of Cd3As2 ,Na3Bi , and Ca3P2 .

  8. Flow directions in ash-flow tuffs: a comparison of geological and magnetic susceptibility measurements, Tshirege member (upper Bandelier Tuff), Valles caldera, New Mexico, USA

    NASA Astrophysics Data System (ADS)

    Macdonadl, W. D.; Palmer, H. C.

    1990-12-01

    This study concludes that the elongation axis ( K 1) of the ellipsoid of anisotropic magnetic susceptibility (AMS) is a suitable proxy for flow axis in ashflow tuffs. 153 oriented samples (176 specimens) were studied from 18 sites in the 1.1 Ma Tshirege member of the Bandelier Tuff. These sites are distributed around the Valles caldera at distances of 5 25 km outside of the rim. K 1 axes correlate well with postulated radial flow axes at 13 sites. K 1 also agrees with measured geological flow indicators, mainly imbricated larger clasts, at 7 sites. At 2 of the 5 sites where significant disagreement is seen between theoretical radial flow directions and measured K 1 axes, the K 1 axes correspond well with geological flow indicators, indicating that the divergence of flow from the predicted radial flow pattern is real. Two major topographic buttresses are suggested as the cause of flow divergence for the Tshirege ash flows: the San Pedro buttress northwest of the caldera, and the San Miguel buttress in the southeast. In situ K 1 axes plunge about 7° toward the source at two-thirds of the sites; therefore the plunge of K 1 is a plausible in situ indicator for the direction of flow. Multiple flow zones in sections of several meters thickness indicate changes of flow direction that are both rapid and large during ash-flow emplacement. These observations raisre the question of how best to represent ‘mean’ flow directions in ash-flow sheets: by eigenvector methods, by vector-sum methods, or by modes. A method for measuring imbrication of larger clasts using apparent dips in vertical joints is outlined. Imbrication, determined in this way at one-third of the sites, dips toward the source, i.e., up-flow. The minimum ( K 3) axis of the AMS ellipsoid correlates with the flow foliation rather than with the larger clast imbrication. The flow axes of ash flows correspond with the K 1 axes, not with the declination of K 3 axes as suggested by some authors. Initial dip of the

  9. AC losses in multifilamentary Bi(2223) tapes with an interfilamentary resistive carbonate barrier

    NASA Astrophysics Data System (ADS)

    Eckelmann, H.; Quilitz, M.; Oomen, M.; Leghissa, M.; Goldacker, W.

    1998-12-01

    For the most common AC application frequencies, the main component of the AC losses in multifilamentary Bi(2223) tapes are caused by hysteresis- and coupling losses. These losses can be reduced enhancing the matrix resistivity and applying a twist to the filaments. We report on the AC loss properties of 37-filament tapes with AgAu (8 wt.%) matrix, and novel 19-filament tapes with SrCO 3 barriers between the filaments. We performed transport AC loss and magnetic AC loss measurements in parallel and perpendicular magnetic fields. Both kinds of tapes were also prepared with filament twists below a twist pitch of 20 mm. The influence of the different tape modifications on the AC loss behaviour is presented and compared with theoretical models to understand the effect of the resistive matrix. In the case of magnetic AC loss measurements, reduced AC losses due to decoupled filaments were observed for the twisted tapes with a resistive matrix in low parallel fields.

  10. A dry-cooled AC quantum voltmeter

    NASA Astrophysics Data System (ADS)

    Schubert, M.; Starkloff, M.; Peiselt, K.; Anders, S.; Knipper, R.; Lee, J.; Behr, R.; Palafox, L.; Böck, A. C.; Schaidhammer, L.; Fleischmann, P. M.; Meyer, H.-G.

    2016-10-01

    The paper describes a dry-cooled AC quantum voltmeter system operated up to kilohertz frequencies and 7 V rms. A 10 V programmable Josephson voltage standard (PJVS) array was installed on a pulse tube cooler (PTC) driven with a 4 kW air-cooled compressor. The operating margins at 70 GHz frequencies were investigated in detail and found to exceed 1 mA Shapiro step width. A key factor for the successful chip operation was the low on-chip power consumption of 65 mW in total. A thermal interface between PJVS chip and PTC cold stage was used to avoid a significant chip overheating. By installing the cryocooled PJVS array into an AC quantum voltmeter setup, several calibration measurements of dc standards and calibrator ac voltages up to 2 kHz frequencies were carried out to demonstrate the full functionality. The results are discussed and compared to systems with standard liquid helium cooling. For dc voltages, a direct comparison measurement between the dry-cooled AC quantum voltmeter and a liquid-helium based 10 V PJVS shows an agreement better than 1 part in 1010.

  11. AC Optimal Power Flow

    SciTech Connect

    2016-10-04

    In this work, we have implemented and developed the simulation software to implement the mathematical model of an AC Optimal Power Flow (OPF) problem. The objective function is to minimize the total cost of generation subject to constraints of node power balance (both real and reactive) and line power flow limits (MW, MVAr, and MVA). We have currently implemented the polar coordinate version of the problem. In the present work, we have used the optimization solver, Knitro (proprietary and not included in this software) to solve the problem and we have kept option for both the native numerical derivative evaluation (working satisfactorily now) as well as for analytical formulas corresponding to the derivatives being provided to Knitro (currently, in the debugging stage). Since the AC OPF is a highly non-convex optimization problem, we have also kept the option for a multistart solution. All of these can be decided by the user during run-time in an interactive manner. The software has been developed in C++ programming language, running with GCC compiler on a Linux machine. We have tested for satisfactory results against Matpower for the IEEE 14 bus system.

  12. Magnetic susceptibility, petrofabrics and strain

    NASA Astrophysics Data System (ADS)

    Borradaile, Graham John

    1988-12-01

    Magnetic susceptibility is a non-destructive technique for quantifying the average fabric of a small sample of rock. The interpretation of the magnetic fabric is not always straightforward. However, the principal directions of the magnitude ellipsoid of susceptibility commonly show orientations consistent with the kinematic interpretations of folds, shear zones and other structural features. The directions may correspond with the orientations of strained objects or with the planar-linear mineral orientations. There will usually be multiple mineralogical sources of susceptibility, often involving silicates. If the sources are known, or if the susceptibility can be attributed to a single mineral species, it may be possible to establish a correlation between the strain ellipsoid and the susceptibility ellipsoid. This correlation will be of principal directions in many instances and occasionally there may be a weak correlation of strain magnitudes as well. In other circumstances it may be possible to establish a correlation between changes in susceptibility and the strain. Nevertheless magnetic fabric studies are not routine substitutes for strain analysis. Even where information on strain is not provided, the magnetic fabrics (and subfabrics) yield a measure of the preferred crystallographic orientation or preferred dimensional orientation of the minerals that may be integrated profitably with other petrofabric data. Experimental deformation of certain synthetic aggregates indicates that directions of magnetic susceptibility spin rapidly with advancing strain, especially where the matrix grains undergo crystal-plastic deformation. In certain experiments, simple shear appears to change the intensity of magnetic fabric more effectively than pure shear. Experiments indicate also that the initial anisotropy of a rock-like material is not easily overprinted by deformation whereas field studies are equivocal.

  13. Identification of /sup 233/Ac

    SciTech Connect

    Chu, Y.Y.; Zhou, M.L.

    1983-09-01

    We report in this paper identification of the new isotope /sup 233/Ac. Uranium targets were irradiated with 28 GeV protons; after rapid retrieval of the target and separation of actinium from thorium, /sup 233/Ac was allowed to decay into the known /sup 233/Th daughter. Exhaustive chemical purification was employed to permit the identification of /sup 233/Th via its characteristic ..gamma.. radiations. The half-life derived for /sup 233/Ac from several experiments is 2.3 +- 0.3 min. The production cross section for /sup 233/Ac is 100 ..mu..b.

  14. Basic concepts of induced AC voltages on pipelines

    SciTech Connect

    Kirkpatrick, E.L.

    1995-07-01

    The phenomena of induced AC on pipelines sharing common rights-of-way with overhead high-voltage electrical transmission power lines is discussed. Basic concepts and techniques for personnel safety and some pipeline protective measures are reviewed.

  15. Identification of highly susceptible individuals in complex networks

    NASA Astrophysics Data System (ADS)

    Tang, Shaoting; Teng, Xian; Pei, Sen; Yan, Shu; Zheng, Zhiming

    2015-08-01

    Identifying highly susceptible individuals in spreading processes is of great significance in controlling outbreaks. In this paper, we explore the susceptibility of people in susceptible-infectious-recovered (SIR) and rumor spreading dynamics. We first study the impact of community structure on people's susceptibility. Although the community structure can reduce the number of infected people for same infection rate, it will not significantly affect nodes' susceptibility. We find the susceptibility of individuals is sensitive to the choice of spreading dynamics. For SIR spreading, since the susceptibility is highly correlated to nodes' influence, the topological indicator k-shell can better identify highly susceptible individuals, outperforming degree, betweenness centrality and PageRank. In contrast, in rumor spreading model, where nodes' susceptibility and influence have no clear correlation, degree performs the best among considered topological measures. Our finding highlights the significance of both topological features and spreading mechanisms in identifying highly susceptible population.

  16. Alternating current susceptibility study on the cluster glass behavior in disordered β-LiFeO2

    NASA Astrophysics Data System (ADS)

    Liu, Lina; Bie, Xiaofei; Ehrenberg, Helmut; Wang, Chunzhong; Wei, Yingjin; Chen, Gang; Du, Fei

    2011-11-01

    The static and dynamic magnetic behavior of β-LiFeO2 has been investigated by measuring dc and ac susceptibilities. The zero-field-cooled (ZFC) and field-cooled (FC) curves reveal an irreversibility behavior at about 156 K and a broad peak at 129 K, indicating a spin glass transition. However, the dc susceptibility of β-LiFeO2 in FC mode differs from a flat curve as expected for a homogeneous spin glass by an increase below Tirr, which is the characteristic magnetic behavior of a cluster spin glass. The real part of the ac susceptibility shows a broad maximum at 135 K, which shifts to higher temperatures and becomes less pronounced with increasing frequency. The corresponding parameter δ =ΔTf/TfΔlogω = 0.005 is calculated for β-LiFeO2, suggesting a spin glass state rather than superparamagnetism. In addition, three models (the Néel-Arrhenius law, the Vogel-Fulcher law, and the power law) have also been employed to analyze the frequency dependence of Tf, which confirm a cluster spin glass state in β-LiFeO2.

  17. Local quantum thermal susceptibility

    PubMed Central

    De Pasquale, Antonella; Rossini, Davide; Fazio, Rosario; Giovannetti, Vittorio

    2016-01-01

    Thermodynamics relies on the possibility to describe systems composed of a large number of constituents in terms of few macroscopic variables. Its foundations are rooted into the paradigm of statistical mechanics, where thermal properties originate from averaging procedures which smoothen out local details. While undoubtedly successful, elegant and formally correct, this approach carries over an operational problem, namely determining the precision at which such variables are inferred, when technical/practical limitations restrict our capabilities to local probing. Here we introduce the local quantum thermal susceptibility, a quantifier for the best achievable accuracy for temperature estimation via local measurements. Our method relies on basic concepts of quantum estimation theory, providing an operative strategy to address the local thermal response of arbitrary quantum systems at equilibrium. At low temperatures, it highlights the local distinguishability of the ground state from the excited sub-manifolds, thus providing a method to locate quantum phase transitions. PMID:27681458

  18. Resonant AC power system proof-of-concept test program

    NASA Technical Reports Server (NTRS)

    Wappes, Loran J.

    1986-01-01

    Proof-of-concept testing was performed on a 20-kHz, resonant power system breadboard from 1981 through 1985. The testing began with the evaluation of a single, 1.0-kW resonant inverter and progressed to the testing of breadboard systems with higher power levels and more capability. The final breadboard configuration tested was a 25.0-kW breadboard with six inverters providing power to three user-interface modules over a 50-meter, 20-kHz bus. The breadboard demonstrated the ability to synchronize multiple resonant inverters to power a common bus. Single-phase and three-phase 20-kHz power distribution was demonstrated. Simple conversion of 20-kHz to dc and variable-frequency ac was demonstrated as was bidirectional power flow between 20-kHz and dc. Steady state measurements of efficiency, power-factor tolerance, and conducted emissions and conducted susceptibility were made. In addition, transient responses were recorded for such conditions as start up, shut down, load changes. The results showed the 20-kHz resonant system to be a desirable technology for a spacecraft power management and distribution system with multiple users and a utility-type bus.

  19. Cooling Floor AC Systems

    NASA Astrophysics Data System (ADS)

    Jun, Lu; Hao, Ding; Hong, Zhang; Ce, Gao Dian

    The present HVAC equipments for the residential buildings in the Hot-summer-and-Cold-winter climate region are still at a high energy consuming level. So that the high efficiency HVAC system is an urgently need for achieving the preset government energy saving goal. With its advantage of highly sanitary, highly comfortable and uniform of temperature field, the hot-water resource floor radiation heating system has been widely accepted. This paper has put forward a new way in air-conditioning, which combines the fresh-air supply unit and such floor radiation system for the dehumidification and cooling in summer or heating in winter. By analyze its advantages and limitations, we found that this so called Cooling/ Heating Floor AC System can improve the IAQ of residential building while keep high efficiency quality. We also recommend a methodology for the HVAC system designing, which will ensure the reduction of energy cost of users.

  20. Influences of Cry1Ac broccoli on larval survival and oviposition of diamondback moth.

    PubMed

    Yi, Dengxia; Cui, Shusong; Yang, Limei; Fang, Zhiyuan; Liu, Yumei; Zhuang, Mu; Zhang, Yangyong

    2015-01-01

    Larval survival and oviposition behavior of three genotypes of diamondback moth, Plutella xylostella L. (Lepidoptera: Plutellidae), (homozygous Cry1Ac-susceptibile, Cry1Ac-resistant, and their F1 hybrids), on transgenic Bacillus thuringiensis (Bt) broccoli expressing different levels of Cry1Ac protein were evaluated in laboratory. These Bt broccoli lines were designated as relative low, medium, and high, respectively, according to the Cry1Ac content. Untransformed brocccoli plants were used as control. Larval survival of diamondback moth on non-Bt leaves was not significantly different among the three genotypes. The Cry1Ac-resistant larvae could survive on the low level of Bt broccoli plants, while Cry1Ac-susceptible and F1 larvae could not survive on them. The three genotypes of P. xylostella larvae could not survive on medium and high levels of Bt broccoli. In oviposition choice tests, there was no significant difference in the number of eggs laid by the three P. xylostella genotypes among different Bt broccoli plants. The development of Cry1Ac-susceptible and Cry1Ac-resistant P. xylostella on intact Bt plants was also tested in greenhouse. All susceptible P. xylostella larvae died on all Bt plants, while resistant larvae could survive on broccoli, which expresses low Cry1Ac protein under greenhouse conditions. The results of the greenhouse trials were similar to that of laboratory tests. This study indicated that high dose of Bt toxins in broccoli cultivars or germplasm lines is required for effective resistance management.

  1. Mungbean yellow mosaic virus (MYMV) AC4 suppresses post-transcriptional gene silencing and an AC4 hairpin RNA gene reduces MYMV DNA accumulation in transgenic tobacco.

    PubMed

    Sunitha, Sukumaran; Shanmugapriya, Gnanasekaran; Balamani, Veluthambi; Veluthambi, Karuppannan

    2013-06-01

    Mungbean yellow mosaic virus (MYMV) is a legume-infecting geminivirus that causes yellow mosaic disease in blackgram, mungbean, soybean, Frenchbean and mothbean. AC4/C4, which is nested completely within the Rep gene, is less conserved among geminiviruses. Much less is known about its role in viral pathogenesis other than its known role in the suppression of host-mediated gene silencing. Transient expression of MYMV AC4 by agroinfiltration suppressed post-transcriptional gene silencing in Nicotiana benthamiana 16c expressing green fluorescence protein, at a level comparable to MYMV TrAP expression. AC4 full-length gene and an inverted repeat of AC4 (comprising the full-length AC4 sequence in sense and antisense orientations with an intervening intron) which makes a hairpin RNA (hpRNA) upon transcription were introduced into tobacco by Agrobacterium-mediated leaf disc transformation. Leaf discs of the transgenic plants were agroinoculated with partial dimers of MYMV and used to study the effect of the AC4-sense and AC4 hpRNA genes on MYMV DNA accumulation. Leaf discs of two transgenic plants that express the AC4-sense gene displayed an increase in MYMV DNA accumulation. Leaf discs of six transgenic plants containing the AC4 hpRNA gene accumulated small-interfering RNAs (siRNAs) specific to AC4, and upon agroinoculation with MYMV they exhibited a severe reduction in the accumulation of MYMV DNA. Thus, the MYMV AC4 hpRNA gene has emerged as a good candidate to engineer resistance against MYMV in susceptible plants.

  2. Large aperture ac interferometer for optical testing.

    PubMed

    Moore, D T; Murray, R; Neves, F B

    1978-12-15

    A 20-cm clear aperture modified Twyman-Green interferometer is described. The system measures phase with an AC technique called phase-lock interferometry while scanning the aperture with a dual galvanometer scanning system. Position information and phase are stored in a minicomputer with disk storage. This information is manipulated with associated software, and the wavefront deformation due to a test component is graphically displayed in perspective and contour on a CRT terminal.

  3. Invitro antifungal susceptibilities of Candida species to liposomal amphotericin B, determined using CLSI broth microdilution, and amphotericin B deoxycholate, measured using the Etest.

    PubMed

    Lovero, Grazia; De Giglio, Osvalda; Rutigliano, Serafina; Diella, Giusy; Caggiano, Giuseppina; Montagna, Maria Teresa

    2017-03-01

    The antifungal susceptibilities of 598 isolates of Candida spp. (bloodstream and other sterile sites) to liposomal amphotericin B (L-AmB) versus amphotericin B (AmB) were determined. MICs were calculated using the Clinical and Laboratory Standards Institute broth microdilution (M27-A3) method for L-AmB and the Etest method for AmB. The MIC50/MIC90 (µg ml-1) values for L-AmB broth microdilution and AmB Etest were 0.25/1 and 0.19/0.5, respectively. The overall essential agreement (±2 dilutions) was 91.5 %, ranging from 37.5 % (Candida lusitaniae) to 100 % (Candida glabrata and Candida krusei). Categorical agreement between the two methods was categorized based on a previously published breakpoint (susceptible/resistant MIC cut-off of 1 µg ml-1). The overall categorical agreement at the 48 h reading was 97.3 %, ranging from 72.7 % (C. krusei) to 100 % (Candida albicans). Major and very major discrepancies occurred in 2.3 and 0.3 %, respectively. Spearman's ρ was 0.48 (P<0.0001). These results demonstrate the utility of the AmB Etest as a surrogate marker to predict the sensibility and resistance of Candida spp. to L-AmB and thus to support its use in antifungal treatment.

  4. Inheritance patterns, dominance and cross-resistance of Cry1Ab- and Cry1Ac-selected Ostrinia furnacalis (Guenée).

    PubMed

    Zhang, Tiantao; He, Mingxia; Gatehouse, Angharad M R; Wang, Zhenying; Edwards, Martin G; Li, Qing; He, Kanglai

    2014-09-11

    Two colonies of Asian corn borer, Ostrinia furnacalis (Guenée), artificially selected from a Bt-susceptible colony (ACB-BtS) for resistance to Cry1Ab (ACB-AbR) and Cry1Ac (ACB-AcR) toxins, were used to analyze inheritance patterns of resistance to Cry1 toxins. ACB-AbR and ACB-AcR evolved significant levels of resistance, with resistance ratios (RR) of 39-fold and 78.8-fold to Cry1Ab and Cry1Ac, respectively. The susceptibility of ACB-AbR larvae to Cry1Ac and Cry1F toxins, which had not previously been exposed, were significantly reduced, being >113-fold and 48-fold, respectively. Similarly, susceptibility of ACB-AcR larvae to Cry1Ab and Cry1F were also significantly reduced (RR > nine-fold, RR > 18-fold, respectively), indicating cross-resistance among Cry1Ab, Cry1Ac, and Cry1F toxins. However, ACB-AbR and ACB-AcR larvae were equally susceptible to Cry1Ie as were ACB-BtS larvae, indicating no cross-resistance between Cry1Ie and Cry1Ab or Cry1Ac toxins; this may provide considerable benefits in preventing or delaying the evolution of resistance in ACB to Cry1Ab and Cry1Ac toxins. Backcrossing studies indicated that resistance to Cry1Ab toxin was polygenic in ACB-AbR, but monogenic in ACB-AcR, whilst resistance to Cry1Ac toxin was primarily monogenic in both ACB-AbR and ACB-AcR, but polygenic as resistance increased.

  5. Fast electric dipole transitions in Ra-Ac nuclei

    SciTech Connect

    Ahmad, I.

    1985-01-01

    Lifetime of levels in /sup 225/Ra, /sup 225/Ac, and /sup 227/Ac have been measured by delayed coincidence techniques and these have been used to determine the E1 gamma-ray transition probabilities. The reduced E1 transition probabilities. The reduced E1 transition probabilities in /sup 225/Ra and /sup 225/Ac are about two orders of magnitude larger than the values in mid-actinide nuclei. On the other hand, the E1 rate in /sup 227/Ac is similar to those measured in heavier actinides. Previous studies suggest the presence of octupole deformation in all the three nuclei. The present investigation indicates that fast E1 transitions occur for nuclei with octupole deformation. However, the studies also show that there is no one-to-one correspondence between E1 rate and octupole deformation. 13 refs., 4 figs.

  6. Layoff Handling Still Lags ACS Standards.

    ERIC Educational Resources Information Center

    Chemical and Engineering News, 1981

    1981-01-01

    Reviews termination procedures of professional chemists and the compliance of these terminations to the American Chemical Society's (ACS's) Professional Employment Guidelines. Provides the ACS guidelines. (DS)

  7. AC plasma anemometer—characteristics and design

    NASA Astrophysics Data System (ADS)

    Marshall, Curtis; Matlis, Eric; Corke, Thomas; Gogineni, Sivaram

    2015-08-01

    The characteristics and design of a high-bandwidth flow sensor that uses an AC glow discharge (plasma) as the sensing element is presented. The plasma forms in the air gap between two protruding low profile electrodes attached to a probe body. The output from the anemometer is an amplitude modulated version of the AC voltage input that contains information about the mean and fluctuating velocity components. The anemometer circuitry includes resistance and capacitance elements that simulate a dielectric-barrier to maintain a diffuse plasma, and a constant-current feedback control that maintains operation within the desired glow discharge regime over an extended range of air velocities. Mean velocity calibrations are demonstrated over a range from 0 to 140 m s-1. Over this velocity range, the mean output voltage varied linearly with air velocity, providing a constant static sensitivity. The effect of the electrode gap and input AC carrier frequency on the anemometer static sensitivity and dynamic response are investigated. Experiments are performed to compare measurements obtained with a plasma sensor operating at two AC carrier frequencies against that of a constant-temperature hot-wire. All three sensors were calibrated against the same known velocity reference. An uncertainty based on the standard deviation of the velocity calibration fit was applied to the mean and fluctuating velocity measurements of the three sensors. The motivation is not to replace hot-wires as a general measurement tool, but rather as an alternative to hot-wires in harsh environments or at high Mach numbers where they either have difficulty in surviving or lack the necessary frequency response.

  8. HVDC-AC system interaction from AC harmonics. Volume 1. Harmonic impedance calculations. Final report

    SciTech Connect

    Breuer, G D; Chow, J H; Lindh, C B; Miller, N W; Numrich, F H; Price, W W; Turner, A E; Whitney, R R

    1982-09-01

    Improved methods are needed to characterize ac system harmonic behavior for ac filter design for HVDC systems. The purpose of this General Electric Company RP1138 research is to evaluate the present filter design practice and to investigate methods for calculating system harmonic impedances. An overview of ac filter design for HVDC systems and a survey of literature related to filter design have been performed. Two methods for calculating system harmonic impedances have been investigated. In the measurement method, an instrumentation system for measuring system voltage and current has been assembled. Different schemes of using the measurements to calculate system harmonic impedances have been studied. In the analytical method, a procedure to include various operating conditions has been proposed. Computer programs for both methods have been prepared, and the results of the measurement and analytical methods analyzed. A conclusion of the project is that the measurement and analytical methods both provided reasonable results. There are correlations between the measured and analytical results for most harmonics, although there are discrepancies between the assumptions used in the two methods. A sensitivity approach has been proposed to further correlate the results. From the results of the analysis, it is recommended that both methods should be tested further. For the measurement method, more testing should be done to cover different system operating conditions. In the analytical method, more detailed models for representing system components should be studied. In addition, alternative statistical and sensitivity approaches should be attempted.

  9. Search for {beta}-delayed fission of {sup 228}Ac

    SciTech Connect

    Xu Yanbing; Ding Huajie; Yuan Shuanggui; Yang Weifan; Niu Yanning; Li Yingjun; Xiao Yonghou; Zhang Shengdong; Lu Xiting

    2006-10-15

    Radium was radiochemically separated from natural thorium. Thin {sup 228}Ra{yields}{beta}{sup -228}Ac sources were prepared and exposed to mica fission track detectors, and measured by an HPGe {gamma}-ray detector. The {beta}-delayed fission events of {sup 228}Ac were observed and its {beta}-delayed fission probability was found to be (5{+-}2)x10{sup -12}.

  10. Perceptions of breath alcohol concentration (BrAC) levels among a sample of bar patrons with BrAC values of 0.08% or higher.

    PubMed

    Martin, Ryan J; Chaney, Beth H; Cremeens-Matthews, Jennifer; Vail-Smith, Karen

    2016-09-01

    Breath alcohol concentration (BrAC) is a commonly used measure of alcohol intoxication. Because of the potential negative consequences of excessive alcohol consumption, it is important to examine how accurately intoxicated individuals can estimate their BrAC values, especially individuals over the legal BrAC driving threshold (i.e., 0.08%). To better understand perceptions of BrAC values among intoxicated individuals, this field study examined actual BrAC values and BrAC range estimates (0.08% and above, 0.02-0.07%, less than 0.02%) among a sample of bar patrons (N = 454) with BrAC levels at 0.08% or higher. Bivariate and multivariate analyses were conducted to examine the relationship between actual BrAC values and perceived BrAC levels. We also examined whether the following demographic and drinking variables were associated with underestimating BrAC in this sample: gender, age, race, college student status, plans to get home, and hazardous drinking. Results indicated that the majority (60.4%) of participants underestimated their BrAC (i.e., less than 0.08%) and lower BrAC values correlated with underestimating BrAC ranges (p < .001, 95% CI[0.2, 0.6]). Further, females (p = .001, 95% CI[1.3, 3.3]) and participants under 21 (p = .039, 95% CI = 1.0, 2.6) were significantly more likely to estimate their BrAC to be less than 0.08%, which is concerning given that young (less than 21) intoxicated females are a group at high risk for sexual assault on college campuses. (PsycINFO Database Record

  11. BOLD signal effects of transcranial alternating current stimulation (tACS) in the alpha range: A concurrent tACS-fMRI study.

    PubMed

    Vosskuhl, Johannes; Huster, René J; Herrmann, Christoph S

    2016-10-15

    Many studies have proven transcranial alternating current stimulation (tACS) to manipulate brain activity. Until now it is not known, however, how these manipulations in brain activity are represented in brain metabolism or how spatially specific these changes are. Alpha-tACS has been shown to enhance the amplitude of the individual alpha frequency (IAF) and a negative correlation between alpha amplitude and occipital BOLD signal was reported in numerous EEG/fMRI experiments. Thus, alpha-tACS was chosen to test the effects of tACS on the BOLD signal. A reduction thereof was expected during alpha-tACS which shows the spatial extent of tACS effects beyond modeling studies. Three groups of subjects were measured in an MRI scanner, receiving tACS at either their IAF (N=11), 1Hz (control; N=12) or sham (i.e., no stimulation - a second control; N=11) while responding to a visual vigilance task. Stimulation was administered in an interleaved pattern of tACS-on runs and tACS-free baseline periods. The BOLD signal was analyzed in response to tACS-onset during resting state and in response to seldom target stimuli. Alpha-tACS at 1.0mA reduced the task-related BOLD response to visual targets in the occipital cortex as compared to tACS-free baseline periods. The deactivation was strongest in an area where the BOLD signal was shown to correlate negatively with alpha amplitude. A direct effect of tACS on resting state BOLD signal levels could not be shown. Our findings suggest that tACS-related changes in BOLD activity occur only as a modulation of an existing BOLD response.

  12. THE ACS NEARBY GALAXY SURVEY TREASURY

    SciTech Connect

    Dalcanton, Julianne J.; Williams, Benjamin F.; Rosema, Keith; Gogarten, Stephanie M.; Christensen, Charlotte; Gilbert, Karoline; Hodge, Paul; Seth, Anil C.; Dolphin, Andrew; Holtzman, Jon; Skillman, Evan D.; Weisz, Daniel; Cole, Andrew; Girardi, Leo; Karachentsev, Igor D.; Olsen, Knut; Freeman, Ken; Gallart, Carme; De Jong, Roelof S. E-mail: ben@astro.washington.edu E-mail: stephanie@astro.washington.edu E-mail: fabio@astro.washington.edu E-mail: aseth@cfa.harvard.edu

    2009-07-15

    The ACS Nearby Galaxy Survey Treasury (ANGST) is a systematic survey to establish a legacy of uniform multi-color photometry of resolved stars for a volume-limited sample of nearby galaxies (D < 4 Mpc). The survey volume encompasses 69 galaxies in diverse environments, including close pairs, small and large groups, filaments, and truly isolated regions. The galaxies include a nearly complete range of morphological types spanning a factor of {approx}10{sup 4} in luminosity and star formation rate. The survey data consist of images taken with the Advanced Camera for Surveys (ACS) on the Hubble Space Telescope (HST), supplemented with archival data and new Wide Field Planetary Camera 2 (WFPC2) imaging taken after the failure of ACS. Survey images include wide field tilings covering the full radial extent of each galaxy, and single deep pointings in uncrowded regions of the most massive galaxies in the volume. The new wide field imaging in ANGST reaches median 50% completenesses of m {sub F475W} = 28.0 mag, m {sub F606W} = 27.3 mag, and m {sub F814W} = 27.3 mag, several magnitudes below the tip of the red giant branch (TRGB). The deep fields reach magnitudes sufficient to fully resolve the structure in the red clump. The resulting photometric catalogs are publicly accessible and contain over 34 million photometric measurements of >14 million stars. In this paper we present the details of the sample selection, imaging, data reduction, and the resulting photometric catalogs, along with an analysis of the photometric uncertainties (systematic and random), for both ACS and WFPC2 imaging. We also present uniformly derived relative distances measured from the apparent magnitude of the TRGB.

  13. The ACS Nearby Galaxy Survey Treasury

    NASA Astrophysics Data System (ADS)

    Dalcanton, Julianne J.; Williams, Benjamin F.; Seth, Anil C.; Dolphin, Andrew; Holtzman, Jon; Rosema, Keith; Skillman, Evan D.; Cole, Andrew; Girardi, Léo; Gogarten, Stephanie M.; Karachentsev, Igor D.; Olsen, Knut; Weisz, Daniel; Christensen, Charlotte; Freeman, Ken; Gilbert, Karoline; Gallart, Carme; Harris, Jason; Hodge, Paul; de Jong, Roelof S.; Karachentseva, Valentina; Mateo, Mario; Stetson, Peter B.; Tavarez, Maritza; Zaritsky, Dennis; Governato, Fabio; Quinn, Thomas

    2009-07-01

    The ACS Nearby Galaxy Survey Treasury (ANGST) is a systematic survey to establish a legacy of uniform multi-color photometry of resolved stars for a volume-limited sample of nearby galaxies (D < 4 Mpc). The survey volume encompasses 69 galaxies in diverse environments, including close pairs, small and large groups, filaments, and truly isolated regions. The galaxies include a nearly complete range of morphological types spanning a factor of ~104 in luminosity and star formation rate. The survey data consist of images taken with the Advanced Camera for Surveys (ACS) on the Hubble Space Telescope (HST), supplemented with archival data and new Wide Field Planetary Camera 2 (WFPC2) imaging taken after the failure of ACS. Survey images include wide field tilings covering the full radial extent of each galaxy, and single deep pointings in uncrowded regions of the most massive galaxies in the volume. The new wide field imaging in ANGST reaches median 50% completenesses of m F475W = 28.0 mag, m F606W = 27.3 mag, and m F814W = 27.3 mag, several magnitudes below the tip of the red giant branch (TRGB). The deep fields reach magnitudes sufficient to fully resolve the structure in the red clump. The resulting photometric catalogs are publicly accessible and contain over 34 million photometric measurements of >14 million stars. In this paper we present the details of the sample selection, imaging, data reduction, and the resulting photometric catalogs, along with an analysis of the photometric uncertainties (systematic and random), for both ACS and WFPC2 imaging. We also present uniformly derived relative distances measured from the apparent magnitude of the TRGB.

  14. Ac loss calorimeter for three-phase cable

    SciTech Connect

    Daney, D.E.; Boenig, H.J.; Maley, M.P.; McMurry, D.E.; DeBlanc, B.G.

    1996-10-01

    A calorimeter for measuring ac losses in meter-long lengths of HTS superconducting power transmission line cables is described. The calorimeter, which is based on a temperature difference technique, has a precision of 1 mW and measures single, two-phase (coupling), and three-phase losses. The measurements show significant coupling losses between phases.

  15. Vessel size index measurements in a rat model of glioma: comparison of the dynamic (Gd) and steady-state (iron-oxide) susceptibility contrast MRI approaches.

    PubMed

    Pannetier, Nicolas; Lemasson, Benjamin; Christen, Thomas; Tachrount, Mohamed; Troprès, Irène; Farion, Régine; Segebarth, Christoph; Rémy, Chantal; Barbier, Emmanuel L

    2012-02-01

    Vessel size index (VSI), a parameter related to the distribution of vessel diameters, may be estimated using two MRI approaches: (i) dynamic susceptibility contrast (DSC) MRI following the injection of a bolus of Gd-chelate. This technique is routinely applied in the clinic to assess intracranial tissue perfusion in patients; (ii) steady-state susceptibility contrast with USPIO contrast agents, which is considered here as the standard method. Such agents are not available for human yet and the steady-state approach is currently limited to animal studies. The aim is to compare VSI estimates obtained with these two approaches on rats bearing C6 glioma (n = 7). In a first session, VSI was estimated from two consecutive injections of Gd-Chelate (Gd(1) and Gd(2)). In a second session (4 hours later), VSI was estimated using USPIO. Our findings indicate that both approaches yield comparable VSI estimates both in contralateral (VSI{USPIO} = 7.5 ± 2.0 µm, VSI{Gd(1)} = 6.5 ± 0.7 µm) and in brain tumour tissues (VSI{USPIO} = 19.4 ± 7.1 µm, VSI{Gd(1)} = 16.6 ± 4.5 µm). We also observed that, in the presence of BBB leakage (as it occurs typically in brain tumours), applying a preload of Gd-chelate improves the VSI estimate with the DSC approach both in contralateral (VSI{Gd(2)} = 7.1 ± 0.4 µm) and in brain tumour tissues (VSI{Gd(2)} = 18.5 ± 4.3 µm) but is not mandatory. VSI estimates do not appear to be sensitive to T(1) changes related to Gd extravasation. These results suggest that robust VSI estimates may be obtained in patients at 3 T or higher magnetic fields with the DSC approach.

  16. In vivo measurement of tissue damage, oxygen saturation changes and blood flow changes after experimental traumatic brain injury in rats using susceptibility weighted imaging.

    PubMed

    Shen, Yimin; Kou, Zhifeng; Kreipke, Christian W; Petrov, Theodor; Hu, Jiani; Haacke, E Mark

    2007-02-01

    Traumatic brain injury (TBI) is a prevalent disease, and many TBI patients experience disturbed cerebral blood flow (CBF) after injury. Moreover, TBI is difficult to quantify with conventional imaging modalities. In this paper, we utilized susceptibility weighted imaging (SWI) as a means to monitor functional blood oxygenation changes and to quantify CBF changes in animals after trauma. In this study using six rats, brain trauma was induced by a weight drop model and the brain was scanned over four time points: pre trauma, and 4 h, 24 h and 48 h post trauma. Five rats survived and one died after trauma. A blood phase analysis using filtered SWI phase images suggested that three rats recovered after 48 h and two rats deteriorated. SWI also suggested that CBF decreased by up to 26%. The CBF change is in agreement with the results of arterial spin labeling methods conducted in this study and with previously published results. Furthermore, SWI revealed an enlargement of the major venous vasculature in deep brain structures, in accordance with the location of diffuse axonal injury. Compared with the traditional, invasive, clinical monitoring of cerebral vascular damage and reduction in blood flow, this method offers a novel, safe and noninvasive approach to quantify changes in oxygen saturation and CBF and to visualize structural changes in blood vasculature after TBI.

  17. Evolution of AC conductivity of wet illitic clay during drying

    NASA Astrophysics Data System (ADS)

    Csáki, Š.; Štubňa, I.; Trnovcová, V.; Ondruška, J.; Vozár, L.; Dobroň, P.

    2017-02-01

    The evolution of the AC electrical conductivity during drying as well as the relationship between sample volume and moisture of green illite samples were investigated. The samples were prepared from illitic clay (80 mass % illite, 4 mass % montmorillonite, 12 mass % quartz and 4 mass % of orthoclase) and distilled water with initial moisture content 36 mass % and were freely dried in air. Conductivity was measured by the volt-ampere method with AC power supply of 5 V in the frequency range from 50 Hz to 10 kHz. The AC conductivity steeply increased with increasing moisture, up to 15 mass %. At higher values of the moisture, the AC conductivity was high and almost constant. The volume of samples increased with increasing moisture when the moisture was higher than 8 mass %. Below this value, the dimensions of samples do not significantly change. The dependence of the relative volume change on moisture is presented in a form of the Bigot’s curve.

  18. Relations between ac-dc components and optical path length in photoplethysmography

    NASA Astrophysics Data System (ADS)

    Lee, Chungkeun; Sik Shin, Hang; Lee, Myoungho

    2011-07-01

    Photoplethysmography is used in various areas such as vital sign measurement, vascular characteristics analysis, and autonomic nervous system assessment. Photoplethysmographic signals are composed of ac and dc, but it is difficult to find research about the interaction of photoplethysmographic components. This study suggested a model equation combining two Lambert-Beer equations at the onset and peak points of photoplethysmography to evaluate ac characteristics, and verified the model equation through simulation and experiment. In the suggested equation, ac was dependent on dc and optical path length. In the simulation, dc was inversely proportionate to ac sensitivity (slope), and ac and optical path length were proportionate. When dc increased from 10% to 90%, stabilized ac decreased from 1 to 0.89 +/- 0.21, and when optical path length increased from 10% to 90%, stabilized ac increased from 1 to 1.53 +/- 0.40.

  19. Diagnostics of the Fermilab Tevatron using an AC dipole

    SciTech Connect

    Miyamoto, Ryoichi

    2008-08-01

    The Fermilab Tevatron is currently the world's highest energy colliding beam facility. Its counter-rotating proton and antiproton beams collide at 2 TeV center-of-mass. Delivery of such intense beam fluxes to experiments has required improved knowledge of the Tevatron's beam optical lattice. An oscillating dipole magnet, referred to as an AC dipole, is one of such a tool to non-destructively assess the optical properties of the synchrotron. We discusses development of an AC dipole system for the Tevatron, a fast-oscillating (f ~ 20 kHz) dipole magnet which can be adiabatically turned on and off to establish sustained coherent oscillations of the beam particles without affecting the transverse emittance. By utilizing an existing magnet and a higher power audio amplifier, the cost of the Tevatron AC dipole system became relatively inexpensive. We discuss corrections which must be applied to the driven oscillation measurements to obtain the proper interpretation of beam optical parameters from AC dipole studies. After successful operations of the Tevatron AC dipole system, AC dipole systems, similar to that in the Tevatron, will be build for the CERN LHC. We present several measurements of linear optical parameters (beta function and phase advance) for the Tevatron, as well as studies of non-linear perturbations from sextupole and octupole elements.

  20. Exenatide: AC 2993, AC002993, AC2993A, exendin 4, LY2148568.

    PubMed

    2004-01-01

    Exenatide [AC002993, AC2993A, AC 2993, LY2148568, exendin 4], a glucagon-like peptide-1 (GLP-1) agonist, is a synthetic exendin 4 compound under development with Amylin Pharmaceuticals for the treatment of type 2 diabetes. Both exendin 4 and its analogue, exendin 3, are 39-amino acid peptides isolated from Heloderma horridum lizard venom that have different amino acids at positions 2 and 3, respectively. Exendins are able to stimulate insulin secretion in response to rising blood glucose levels, and modulate gastric emptying to slow the entry of ingested sugars into the bloodstream. Amylin Pharmaceuticals acquired exclusive patent rights for the two exendin compounds (exendin 3 and exendin 4) from the originator, Dr John Eng (Bronx, NY, US). On 20 September 2002, Amylin and Eli Lilly signed a collaborative agreement for the development and commercialisation of exenatide for type 2 diabetes. Under the terms of the agreement, Eli Lilly has paid Amylin a licensing fee of 80 million US dollars and bought Amylin's stock worth 30 million US dollars at 18.69 US dollars a share. After the initial payment, Eli Lilly will pay Amylin up to 85 US dollars million upon reaching certain milestones and also make an additional payment of up to 130 million US dollars upon global commercialisation of exenatide. Both companies will share the US development and commercialisation costs, while Eli Lilly will pick up up to 80% of development costs and all commercialisation costs outside the US. Amylin and Eli Lilly will equally share profit from sales in the US, while Eli Lilly will get 80% of the profit outside the US and Amylin will get the rest. This agreement has also enabled Amylin to train its sales force to co-promote Lilly's human growth hormone Humatrope. Alkermes will receive research and development funding and milestone payments, and also a combination of royalty payments and manufacturing fees based on product sales. Alkermes undertakes the responsibility for the development

  1. Magnetic susceptibility of tetragonal titanium dioxide

    USGS Publications Warehouse

    Senftle, F.E.; Pankey, T.; Grant, F.A.

    1960-01-01

    Careful measurements have been made of the magnetic susceptibility of the rutile and anatase crystalline forms of titanium dioxide. The magnetic susceptibility of a single crystal of high-purity rutile was found to be (0.067??0.0015)??10-6 emu per gram, and was temperature-independent from 55??to 372??K. Difficulty was encountered in obtaining a good value of the magnetic susceptibility of anatase because of impurities. However, a value of 0.02??10-6 emu per gram was obtained as a maximum value for anatase powder. A discussion is given for the different values obtained for anatase and rutile. ?? 1960 The American Physical Society.

  2. Accelerator Production of 225Ac For Alpha-Immunotherapy

    NASA Astrophysics Data System (ADS)

    Weidner, J. W.; Nortier, F. M.; Bach, H. T.; John, K. D.; Couture, A.; Ullmann, J. L.; Fassbender, M. E.; Goff, G. S.; Taylor, W.; Valdez, F.; Wolfsberg, L. E.; Cisneros, M.; Dry, D.; Gallegos, M.; Gritzo, R.; Bitteker, L. J.; Wender, S.; Baty, R. S.

    2011-06-01

    225Ac has tremendous potential for the treatment of metastatic cancer due to the four alpha-particles emitted during its decay to stable 209Bi. Additionally, it is one of the few alpha-emitters being considered for clinical trials. The anticipated 225Ac demand for these trials is expected to far exceed the annual worldwide supply of approximately 1,000 mCi/yr. Consequently, the DOE Office of Science has funded investigations into accelerator-based production of 225Ac. Existing 232Th(p,x)225Ac cross section data indicate that up to 480 mCi/day of 225Ac could be created by bombarding a thick target of natural thorium with 100 MeV protons at the Los Alamos Isotope Production Facility. To verify these predictions, experiments are underway at the Los Alamos Neutron Science Center to measure the 232Th(p,x)225Ac production cross sections for protons in the energy range 40-200 MeV, and at 800 MeV. For 800 MeV protons, preliminary results indicate that the 225Ac production cross section is 12.4±0.6 mb and the 225Ra production cross section is 3.2±0.2 mb. Moreover, preliminary results suggest that the 227Ac production cross section is 16±1 mb. Experiments to measure these same cross sections at proton energies below 200 MeV are planned for the last half of calendar year 2010.

  3. Accelerator Production of {sup 225}Ac For Alpha-Immunotherapy

    SciTech Connect

    Weidner, J. W.; Nortier, F. M.; Bach, H. T.; John, K. D.; Couture, A.; Ullmann, J. L.; Fassbender, M. E.; Goff, G. S.; Taylor, W.; Valdez, F.; Wolfsberg, L. E.; Cisneros, M.; Dry, D.; Gallegos, M.; Gritzo, R.; Bitteker, L. J.; Wender, S.; Baty, R. S.

    2011-06-01

    {sup 225}Ac has tremendous potential for the treatment of metastatic cancer due to the four alpha-particles emitted during its decay to stable {sup 209}Bi. Additionally, it is one of the few alpha-emitters being considered for clinical trials. The anticipated {sup 225}Ac demand for these trials is expected to far exceed the annual worldwide supply of approximately 1,000 mCi/yr. Consequently, the DOE Office of Science has funded investigations into accelerator-based production of {sup 225}Ac. Existing {sup 232}Th(p,x){sup 225}Ac cross section data indicate that up to 480 mCi/day of {sup 225}Ac could be created by bombarding a thick target of natural thorium with 100 MeV protons at the Los Alamos Isotope Production Facility. To verify these predictions, experiments are underway at the Los Alamos Neutron Science Center to measure the {sup 232}Th(p,x){sup 225}Ac production cross sections for protons in the energy range 40-200 MeV, and at 800 MeV. For 800 MeV protons, preliminary results indicate that the {sup 225}Ac production cross section is 12.4{+-}0.6 mb and the {sup 225}Ra production cross section is 3.2{+-}0.2 mb. Moreover, preliminary results suggest that the {sup 227}Ac production cross section is 16{+-}1 mb. Experiments to measure these same cross sections at proton energies below 200 MeV are planned for the last half of calendar year 2010.

  4. Antifungal susceptibility testing.

    PubMed Central

    Rex, J H; Pfaller, M A; Rinaldi, M G; Polak, A; Galgiani, J N

    1993-01-01

    Unlike antibacterial susceptibility testing, reliable antifungal susceptibility testing is still largely in its infancy. Many methods have been described, but they produce widely discrepant results unless such factors as pH, inoculum size, medium formulation, incubation time, and incubation temperature are carefully controlled. Even when laboratories agree upon a common method, interlaboratory agreement may be poor. As a result of numerous collaborative projects carried out both independently and under the aegis of the Subcommittee on Antifungal Susceptibility Testing of the National Committee for Clinical Laboratory Standards, the effects of varying these factors have been extensively studied and a standard method which minimizes interlaboratory variability during the testing of Candida spp. and Cryptococcus neoformans has been proposed. This review summarizes this work, reviews the strengths and weaknesses of the proposed susceptibility testing standard, and identifies directions for future work. PMID:8269392

  5. MR Susceptibility Imaging

    PubMed Central

    Duyn, Jeff

    2012-01-01

    This work reviews recent developments in the use of magnetic susceptibility contrast for human MRI, with a focus on the study of brain anatomy. The increase in susceptibility contrast with modern high field scanners has led to novel applications and insights into the sources and mechanism contributing to this contrast in brain tissues. Dedicated experiments have demonstrated that in most of healthy brain, iron and myelin dominate tissue susceptibility variations, although their relative contribution varies substantially. Local variations in these compounds can affect both amplitude and frequency of the MRI signal. In white matter, the myelin sheath introduces an anisotropic susceptibility that has distinct effects on the water compartments inside the axons, between the myelin sheath, and the axonal space, and renders their signals dependent on the angle between the axon and the magnetic field. This offers opportunities to derive tissue properties specific to these cellular compartments. PMID:23273840

  6. Calculate waveguide aperture susceptance

    NASA Astrophysics Data System (ADS)

    Kwon, J.-K.; Ishii, T. K.

    1982-12-01

    A method is developed for calculating aperture susceptance which makes use of the distribution of an aperture's local fields. This method can be applied to the computation of the aperture susceptance of irises, as well as the calculation of the susceptances of waveguide filters, aperture antennas, waveguide cavity coupling, waveguide junctions, and heterogeneous boundaries such as inputs to ferrite or dielectric loaded waveguides. This method assumes a local field determined by transverse components of the incident wave in the local surface of the cross section in the discontinuity plane which lies at the aperture. The aperture susceptance is calculated by the use of the local fields, the law of energy conservation, and the principles of continuity of the fields. This method requires that the thickness of the aperture structure be zero, but this does not limit the practical usefulness of this local-field method.

  7. Obtaining DC and AC isothermal electrical characteristics for RF MOSFET

    NASA Astrophysics Data System (ADS)

    Sahoo, A. K.; Fregonese, S.; Scheer, P.; Celi, D.; Juge, A.; Zimmer, T.

    2015-04-01

    In this paper we demonstrate a new and simple approach to obtain isothermal electrical characteristics of metal oxide field effect transistor (MOSFET) from conventional non-isothermal measurements. DC and continuous wave (CW) S-parameter measurements are performed at different chuck temperatures (Tchuck). Knowing the thermal resistance (RTH) of the device the variation of DC and AC characteristic due to self-heating can be de-embedded and all the isothermal DC data and AC data above isothermal frequency can be determined. The method is validated by comparing the results with pulsed DC and pulsed RF measurements and found to be in good agreements.

  8. [Measles and chickenpox susceptibility among immigrants].

    PubMed

    Gétaz, Laurent; Casillas, Alejandra; Wolff, Hans

    2016-05-04

    Exposure of immigrants to infectious diseases in their country of origin influences their susceptibility to infections later in life. Susceptibility to certain infections may significantly differs between immigrants depending on their regions of origin. Both measles and chickenpox (varicella) are conditions for which the level of exposure in the country of origin influences the preventive measures that immigrant health providers should propose. Through these two illustrative examples, this article summarizes the practical implications for clinicians who care for immigrants originating from southern countries.

  9. Quantitative susceptibility mapping for investigating subtle susceptibility variations in the human brain.

    PubMed

    Schweser, Ferdinand; Sommer, Karsten; Deistung, Andreas; Reichenbach, Jürgen Rainer

    2012-09-01

    Quantitative susceptibility mapping (QSM) is a novel magnetic resonance-based technique that determines tissue magnetic susceptibility from measurements of the magnetic field perturbation. Due to the ill-posed nature of this problem, regularization strategies are generally required to reduce streaking artifacts on the computed maps. The present study introduces a new algorithm for calculating the susceptibility distribution utilizing a priori information on its regional homogeneity derived from gradient echo phase images and analyzes the impact of erroneous a priori information on susceptibility map fidelity. The algorithm, Homogeneity Enabled Incremental Dipole Inversion (HEIDI), was investigated with a special focus on the reconstruction of subtle susceptibility variations in a numerical model and in volunteer data and was compared with two recently published approaches, Thresholded K-space Division (TKD) and Morphology Enabled Dipole Inversion (MEDI). HEIDI resulted in susceptibility maps without streaking artifacts and excellent depiction of subtle susceptibility variations in most regions. By investigating HEIDI susceptibility maps acquired with the volunteers' heads in different orientations, it was demonstrated that the apparent magnetic susceptibility distribution of human brain tissue considerably depends on the direction of the main magnetic field.

  10. Phase-sensitive inductive detection of ac currents due to spin-pumping/inverse spin Hall effect in unpatterned Permalloy/Pt bilayers

    NASA Astrophysics Data System (ADS)

    Silva, Thomas; Nembach, Hans; Shaw, Justin; Karenowska, Alexy; Weiler, Mathias

    We present a new method to measure the ac inverse spin Hall effect at GHz frequencies. Unlike previous methods, our does not rely on any patterning or electrical contacts. We utilize phase-sensitive, broad-band, perpendicular-field ferromagnetic resonance to detect the ac current by the inverse spin Hall effect (iSHE) in Py/Pt bilayers. The iSHE component of the signal is non-linear in the excitation frequency; while the inductive FMR response scales linearly with frequency, the iSHE signal scales quadratically because the iSHE current itself is proportional to dm/dt. This differential gain affords us detection of previously unreported higher order contributions to the iSHE signal. We compare FMR measurements with a control samples that do not include the high spin-orbit layer, e.g. Pt. Data sets with and without Pt are normalized by the complex Polder susceptibility, which nullifies any effects due to differences in line-width and anisotropy. The complex ratio of the normalized inductive amplitudes is analyzed with a simple model that considers how the ac currents generated by the iSHE couple inductively back into the excitations waveguide. The linear iSHE signal agrees with previous reported values. The nonlinear iSHE signal is 3-4 orders of magnitude weaker, but is easily detected over the frequency range of 5-45 GHz

  11. Anisotropy of the magnetic susceptibility of gallium

    USGS Publications Warehouse

    Pankey, T.

    1960-01-01

    The bulk magnetic susceptibilities of single gallium crystals and polycrystalline gallium spheres were measured at 25??C. The following anisotropic diamagnetic susceptibilities were found: a axis (-0.119??0. 001)??10-6 emu/g, b axis (-0.416??0.002)??10 -6 emu/g, and c axis (-0.229??0.001) emu/g. The susceptibility of the polycrystalline spheres, assumed to be the average value for the bulk susceptibility of gallium, was (-0.257??0.003)??10-6 emu/g at 25??C, and (-0.299??0.003)??10-6 emu/g at -196??C. The susceptibility of liquid gallium was (0.0031??0.001) ??10-6 emu/g at 30??C and 100??C. Rotational diagrams of the susceptibilities in the three orthogonal planes of the unit cell were not sinusoidal. The anisotropy in the single crystals was presumably caused by the partial overlap of Brillouin zone boundaries by the Fermi-energy surface. The large change in susceptibility associated with the change in state was attributed to the absence of effective mass influence in the liquid state. ?? 1960 The American Institute of Physics.

  12. Prompt and Delayed Spectroscopy of Ac isotopes around N = 126

    NASA Astrophysics Data System (ADS)

    Hota, S. S.; Lane, G. J.; Reed, M. W.; Mitchell, A. J.; Stuchbery, A. E.; Kibedi, T.; Akber, A. A.; Eriksen, T. E.; Gerathy, M. S.; Palalani, N.; Palazzo, T. R.

    2015-10-01

    Nuclei above Z = 82 and around N = 126 are well described by the spherical shell model, with the attractive proton-neutron residual interactions and particle-octupole vibration coupling resulting in energy-favored, isomeric states occurring along the yrast line. Nuclei up to Z = 88 are mostly well known, but information on Ac (Z = 89) isotopes is limited. We report on high-spin, gamma-ray spectroscopy measurements of 214 , 215 , 216 , 217Ac performed at the Australian National University using the CAESAR array and fusion-evaporation reactions between 12C and 14,15N beams delivered by the 14UD accelerator incident on 204Pb and 209Bi targets. States up to 29/2+ isomers were known previously in 215,217Ac, while only one gamma-ray has been assigned to each of 214,216Ac. New level schemes have now been constructed for 214,216Ac and those for 215,217Ac have been significantly extended. The results will be presented in detail together with semi-empirical shell model calculations that support the proposed level schemes.

  13. Introducing AC Inductive Reactance with a Power Tool

    ERIC Educational Resources Information Center

    Bryant, Wesley; Baker, Blane

    2016-01-01

    The concept of reactance in AC electrical circuits is often non-intuitive and difficult for students to grasp. In order to address this lack of conceptual understanding, classroom exercises compare the predicted resistance of a power tool, based on electrical specifications, to measured resistance. Once students discover that measured resistance…

  14. The ACS Nearby Galaxy Survey Treasury

    NASA Astrophysics Data System (ADS)

    Dalcanton, Julianne; Williams, B.; Gogarten, S.; Weisz, D.; Skillman, E.; Seth, A.; ANGST Team

    2007-12-01

    The ACS Nearby Galaxy Survey Treasury program (ANGST) is a program to measure photometry for millions of stars in a volume limited sample of 70 nearby galaxies. With this data set, we are deriving spatially resolved star formation histories for both dwarfs and spirals in the local volume. I will highlight initial results from the survey, including ancient star formation histories for massive spirals, halos around dwarf galaxies, spatially-resolved star formation histories in dwarfs and spirals, and the detection of variable stars. I will also discuss the ANGST involved with switching to WFPC2. This program is funded by NASA grant HST GO-10915, administered by STScI.

  15. Individual susceptibility to toxicity.

    PubMed

    Grandjean, P

    1992-12-01

    Individual variation in susceptibility to chemical toxicity may be due to differences in toxicokinetic patterns or effect modification. Well-documented interspecies genetic differences in susceptibility to chemicals had lead to studies of such variation also within species. Epidemiological evidence now suggests that common variations, particularly in the P-450 enzymes, may play a major role in determining individual susceptibility to chemically-induced disease. Physiologic factors are involved in the particular susceptibility of the fetus, the newborn, and the old. Constitutional susceptibility is also affected by acquired conditions, including chronic disease, such as diabetes mellitus. Perhaps the most complex area relates to the increase in vulnerability caused by previous or contemporary exposure to other factors, thus eliciting, e.g., synergistic effects. Although amply demonstrated by experimental studies, epidemiological or clinical confirmation is generally lacking. One hypothesis suggests that a chemical exposure may affect the reserve capacity of the body, though not resulting in any immediate adverse effect. Subsequently, the body becomes unable to compensate for an additional stress, and toxicity then develops. Epidemiological approaches are available and need to be expanded. Research in this area has potential ethical implications which should be dealt with in an open, informed forum.

  16. Generalized longitudinal susceptibility for magnetic monopoles in spin ice

    PubMed Central

    Bramwell, Steven T.

    2012-01-01

    The generalized longitudinal susceptibility χ(q,ω) affords a sensitive measure of the spatial and temporal correlations of magnetic monopoles in spin ice. Starting with the monopole model, a mean field expression for χ(q,ω) is derived as well as expressions for the mean square longitudinal field and induction at a point. Monopole motion is shown to be strongly correlated, and both spatial and temporal correlations are controlled by the dimensionless monopole density x which defines the ratio of the magnetization relaxation rate and the monopole hop rate. Thermal effects and spin-lattice relaxation are also considered. The derived equations are applicable in the temperature range where the Wien effect for magnetic monopoles is negligible. They are discussed in the context of existing theories of spin ice and the following experimental techniques: DC and AC magnetization, neutron scattering, neutron spin echo and longitudinal and transverse field μSR. The monopole theory is found to unify diverse experimental results, but several discrepancies between theory and experiment are identified. One of these, concerning the neutron scattering line shape, is explained by means of a phenomenological modification to the theory. PMID:23166378

  17. Moment measurements in dynamic and quasi-static spine segment testing using eccentric compression are susceptible to artifacts based on loading configuration.

    PubMed

    Van Toen, Carolyn; Carter, Jarrod W; Oxland, Thomas R; Cripton, Peter A

    2014-12-01

    The tolerance of the spine to bending moments, used for evaluation of injury prevention devices, is often determined through eccentric axial compression experiments using segments of the cadaver spine. Preliminary experiments in our laboratory demonstrated that eccentric axial compression resulted in "unexpected" (artifact) moments. The aim of this study was to evaluate the static and dynamic effects of test configuration on bending moments during eccentric axial compression typical in cadaver spine segment testing. Specific objectives were to create dynamic equilibrium equations for the loads measured inferior to the specimen, experimentally verify these equations, and compare moment responses from various test configurations using synthetic (rubber) and human cadaver specimens. The equilibrium equations were verified by performing quasi-static (5 mm/s) and dynamic experiments (0.4 m/s) on a rubber specimen and comparing calculated shear forces and bending moments to those measured using a six-axis load cell. Moment responses were compared for hinge joint, linear slider and hinge joint, and roller joint configurations tested at quasi-static and dynamic rates. Calculated shear force and bending moment curves had similar shapes to those measured. Calculated values in the first local minima differed from those measured by 3% and 15%, respectively, in the dynamic test, and these occurred within 1.5 ms of those measured. In the rubber specimen experiments, for the hinge joint (translation constrained), quasi-static and dynamic posterior eccentric compression resulted in flexion (unexpected) moments. For the slider and hinge joints and the roller joints (translation unconstrained), extension ("expected") moments were measured quasi-statically and initial flexion (unexpected) moments were measured dynamically. In the cadaver experiments with roller joints, anterior and posterior eccentricities resulted in extension moments, which were unexpected and expected, for those

  18. Ac magnetorestriction hysteresis and magnetization direction in grain oriented silicon steels

    SciTech Connect

    Mogi, Hisashi; Matsuo, Yukio; Kumano, Tomoji

    1999-09-01

    A hysteresis curve of ac magnetostriction was measured, magnetizing a grain oriented silicon steel in the direction deviated from rolling direction of a sample. The ac magnetostriction ({lambda} ac) curves were analyzed as harmonics in the interest of noise spectrum of such as a power transformer. The domain structure model in this magnetostriction process was proposed. The hysteresis was large in the magnetization direction inclined at 30 and 90{degree} from the rolling direction.

  19. Signal quality of the LHC AC dipoles and its impact on beam dynamics

    SciTech Connect

    Miyamoto, R.; Cattin, M.; Serrano, J.; Tomas, R.

    2010-05-23

    The adiabaticity of the AC dipole might be compromised by noise or unwanted frequency components in its signal. An effort has been put to characterize and optimize the signal quality of the LHC AC dipoles. The measured signal is used in realistic simulations in order to evaluate its impact on beam dynamics and to ultimately establish safe margins for the operation of the LHC AC dipoles.

  20. Low-frequency low-field magnetic susceptibility of ferritin and hemosiderin.

    PubMed

    Allen, P D; St Pierre, T G; Chua-anusorn, W; Ström, V; Rao, K V

    2000-02-21

    Low-frequency low-field magnetic susceptibility measurements were made on four samples of mammalian tissue iron oxide deposits. The samples comprised: (1) horse spleen ferritin; (2) dugong liver hemosiderin; (3) thalassemic human spleen ferritin; and (4) crude thalassemic human spleen hemosiderin. These samples were chosen because Mössbauer spectroscopic measurements on the samples indicated that they exemplified the variation in magnetic and mineral structure found in mammalian tissue iron oxide deposits. The AC-magnetic susceptometry yielded information on the magnetization kinetics of the four samples indicating samples 1, 2, and 3 to be superparamagnetic with values of around 10(11) s(-1) for the pre-exponential frequency factor in the Néel-Arrhenius equation and values for characteristic magnetic anisotropy energy barriers in the range 250-400 K. Sample 4 was indicated to be paramagnetic at all temperatures above 1.3 K. The AC-magnetic susceptometry data also indicated a larger magnetic anisotropy energy distribution in the dugong liver sample compared with samples 1 and 3 in agreement with previous Mössbauer spectroscopic data on these samples. At temperatures below 200 K, samples 1-3 exhibited Curie-Weiss law behavior, indicating weak particle-particle interactions tending to favor antiparallel alignment of the particle magnetic moments. These interactions were strongest for the dugong liver hemosiderin, possibly reflecting the smaller separation between mineral particles in this sample. This is the first magnetic susceptometry study of hemosiderin iron deposits and demonstrates that the AC-magnetic susceptometry technique is a fast and informative method of studying such tissue iron oxide deposits.

  1. Concurrent Electroencephalography Recording During Transcranial Alternating Current Stimulation (tACS).

    PubMed

    Fehér, Kristoffer D; Morishima, Yosuke

    2016-01-22

    Oscillatory brain activities are considered to reflect the basis of rhythmic changes in transmission efficacy across brain networks and are assumed to integrate cognitive neural processes. Transcranial alternating current stimulation (tACS) holds the promise to elucidate the causal link between specific frequencies of oscillatory brain activity and cognitive processes. Simultaneous electroencephalography (EEG) recording during tACS would offer an opportunity to directly explore immediate neurophysiological effects of tACS. However, it is not trivial to measure EEG signals during tACS, as tACS creates a huge artifact in EEG data. Here we explain how to set up concurrent tACS-EEG experiments. Two necessary considerations for successful EEG recording while applying tACS are highlighted. First, bridging of the tACS and EEG electrodes via leaking EEG gel immediately saturates the EEG amplifier. To avoid bridging via gel, the viscosity of the EEG gel is the most important parameter. The EEG gel must be viscous to avoid bridging, but at the same time sufficiently fluid to create contact between the tACS electrode and the scalp. Second, due to the large amplitude of the tACS artifact, it is important to consider using an EEG system with a high resolution analog-to-digital (A/D) converter. In particular, the magnitude of the tACS artifact can exceed 100 mV at the vicinity of a stimulation electrode when 1 mA tACS is applied. The resolution of the A/D converter is of importance to measure good quality EEG data from the vicinity of the stimulation site. By following these guidelines for the procedures and technical considerations, successful concurrent EEG recording during tACS will be realized.

  2. Introducing AC inductive reactance with a power tool

    NASA Astrophysics Data System (ADS)

    Bryant, Wesley; Baker, Blane

    2016-09-01

    The concept of reactance in AC electrical circuits is often non-intuitive and difficult for students to grasp. In order to address this lack of conceptual understanding, classroom exercises compare the predicted resistance of a power tool, based on electrical specifications, to measured resistance. Once students discover that measured resistance is smaller than expected, they are asked to explain these observations using previously studied principles of magnetic induction. Exercises also introduce the notion of inductive reactance and impedance in AC circuits and, ultimately, determine self-inductance of the motor windings within the power tool.

  3. Susceptibility of Spodoptera exigua to 9 toxins from Bacillus thuringiensis.

    PubMed

    Hernández-Martínez, Patricia; Ferré, Juan; Escriche, Baltasar

    2008-03-01

    Nine of the most common lepidopteran active Cry proteins from Bacillus thuringiensis have been tested for activity against Spodoptera exigua. Because of possible intraspecific variability, three laboratory strains (FRA, HOL, and MUR) have been used. Mortality assays were performed with the three strains. LC(50) values for the active toxins were determined to the FRA and the HOL strains, whereas susceptibility of the MUR strain was assessed using only two concentrations. The results showed that Cry1Ca, Cry1Da, and Cry1Fa were the most effective toxins with all strains. Cry1Ab was found effective for the HOL strain, but very little effective against FRA (6.5-fold) and MUR strains. Cry1Aa and Cry1Ac were marginally toxic to all strains, whereas the rest of the toxins tested (Cry1Ba, Cry2Aa, and Cry2Ab) were non toxic. Significant differences in susceptibility among strains were also found for Cry1Da, being the FRA strain 25-fold more susceptible than the HOL strain. Growth inhibition, as an additional susceptibility parameter, was determined in the FRA strain with the 9 toxins. The toxicity profile obtained differed from that observed in mortality assays. Cry1Aa, Cry1Ab, Cry1Ac, Cry1Ca, Cry1Da, and Cry1Fa toxins produced a similar larval growth inhibition. Cry2Aa had a lower but clear effect on larval growth inhibition, whereas Cry1Ba and Cry2Ab did not have any effect.

  4. ACS from development to operations

    NASA Astrophysics Data System (ADS)

    Caproni, Alessandro; Colomer, Pau; Jeram, Bogdan; Sommer, Heiko; Chiozzi, Gianluca; Mañas, Miguel M.

    2016-08-01

    The ALMA Common Software (ACS), provides the infrastructure of the distributed software system of ALMA and other projects. ACS, built on top of CORBA and Data Distribution Service (DDS) middleware, is based on a Component- Container paradigm and hides the complexity of the middleware allowing the developer to focus on domain specific issues. The transition of the ALMA observatory from construction to operations brings with it that ACS effort focuses primarily on scalability, stability and robustness rather than on new features. The transition came together with a shorter release cycle and a more extensive testing. For scalability, the most problematic area has been the CORBA notification service, used to implement the publisher subscriber pattern because of the asynchronous nature of the paradigm: a lot of effort has been spent to improve its stability and recovery from run time errors. The original bulk data mechanism, implemented using the CORBA Audio/Video Streaming Service, showed its limitations and has been replaced with a more performant and scalable DDS implementation. Operational needs showed soon the difference between releases cycles for Online software (i.e. used during observations) and Offline software, which requires much more frequent releases. This paper attempts to describe the impact the transition from construction to operations had on ACS, the solution adopted so far and a look into future evolution.

  5. Simple Equipment for Imaging AC.

    ERIC Educational Resources Information Center

    Kamata, Masahiro; Anayama, Takayuki

    2003-01-01

    Presents an effective way to demonstrate the difference between direct current and alternating current using red and green LEDs. Describes how to make a tool that shows how an AC voltage changes with time using the afterimage effect of the LEDs. (Author/NB)

  6. The effect of prism adaptation on the response AC/A ratio.

    PubMed

    Rainey, B B

    2000-05-01

    Vergence adaptation, also known as prism adaptation, is a phenomenon in which a patient's heterophoria changes after prolonged viewing through prism. The effect of prism adaptation on the accommodation-convergence relationship, quantified by the AC/A ratio, is not known. Previous studies of AC/A ratio stability and alterability have used only stimulus AC/A ratio calculations, or have measured accommodative responses to only one or two stimuli. The ideal study of AC/A ratio stability and alterability would measure accommodative responses to several accommodative stimuli, and use these along with vergence responses to calculate response AC/A ratios, rather than stimulus AC/A ratios. In addition, the gradient method should be used to avoid any effect of proximal vergence resulting from changes in target distance. This paper describes a project which investigated the effect of vergence (prism) adaptation on the gradient response AC/A ratio, using accommodative responses measured for five different accommodative stimuli. The response AC/A ratio did not significantly change following a period of adaptation to base-in prism for six of the eight subjects in this study. In addition, the response AC/A ratio did not significantly change following a period of adaptation to base-out prism for six of the eight subjects.

  7. Susceptibility-weighted imaging and quantitative susceptibility mapping in the brain.

    PubMed

    Liu, Chunlei; Li, Wei; Tong, Karen A; Yeom, Kristen W; Kuzminski, Samuel

    2015-07-01

    Susceptibility-weighted imaging (SWI) is a magnetic resonance imaging (MRI) technique that enhances image contrast by using the susceptibility differences between tissues. It is created by combining both magnitude and phase in the gradient echo data. SWI is sensitive to both paramagnetic and diamagnetic substances which generate different phase shift in MRI data. SWI images can be displayed as a minimum intensity projection that provides high resolution delineation of the cerebral venous architecture, a feature that is not available in other MRI techniques. As such, SWI has been widely applied to diagnose various venous abnormalities. SWI is especially sensitive to deoxygenated blood and intracranial mineral deposition and, for that reason, has been applied to image various pathologies including intracranial hemorrhage, traumatic brain injury, stroke, neoplasm, and multiple sclerosis. SWI, however, does not provide quantitative measures of magnetic susceptibility. This limitation is currently being addressed with the development of quantitative susceptibility mapping (QSM) and susceptibility tensor imaging (STI). While QSM treats susceptibility as isotropic, STI treats susceptibility as generally anisotropic characterized by a tensor quantity. This article reviews the basic principles of SWI, its clinical and research applications, the mechanisms governing brain susceptibility properties, and its practical implementation, with a focus on brain imaging.

  8. xopAC-triggered Immunity against Xanthomonas Depends on Arabidopsis Receptor-Like Cytoplasmic Kinase Genes PBL2 and RIPK

    PubMed Central

    Guy, Endrick; Lautier, Martine; Chabannes, Matthieu; Roux, Brice; Lauber, Emmanuelle; Arlat, Matthieu; Noël, Laurent D.

    2013-01-01

    Xanthomonas campestris pv. campestris (Xcc) colonizes the vascular system of Brassicaceae and ultimately causes black rot. In susceptible Arabidopsis plants, XopAC type III effector inhibits by uridylylation positive regulators of the PAMP-triggered immunity such as the receptor-like cytoplasmic kinases (RLCK) BIK1 and PBL1. In the resistant ecotype Col-0, xopAC is a major avirulence gene of Xcc. In this study, we show that both the RLCK interaction domain and the uridylyl transferase domain of XopAC are required for avirulence. Furthermore, xopAC can also confer avirulence to both the vascular pathogen Ralstonia solanacearum and the mesophyll-colonizing pathogen Pseudomonas syringae indicating that xopAC-specified effector-triggered immunity is not specific to the vascular system. In planta, XopAC-YFP fusions are localized at the plasma membrane suggesting that XopAC might interact with membrane-localized proteins. Eight RLCK of subfamily VII predicted to be localized at the plasma membrane and interacting with XopAC in yeast two-hybrid assays have been isolated. Within this subfamily, PBL2 and RIPK RLCK genes but not BIK1 are important for xopAC-specified effector-triggered immunity and Arabidopsis resistance to Xcc. PMID:23951354

  9. Deconvolution with simple extrapolation for improved cerebral blood flow measurement in dynamic susceptibility contrast magnetic resonance imaging during acute ischemic stroke.

    PubMed

    MacDonald, Matthew Ethan; Smith, Michael Richard; Frayne, Richard

    2011-06-01

    Magnetic resonance (MR) perfusion imaging is a clinical technique for measuring brain blood flow parameters during stroke and other ischemic events. Ischemia in brain tissue can be difficult to accurately measure or visualize when using MR-derived cerebral blood flow (CBF) maps. The deconvolution techniques used to estimate flow can introduce a mean transit time-dependent bias following application of noise stabilization techniques. The underestimation of the CBF values, greatest in normal tissues, causes a decrease in the image contrast observed in CBF maps between normally perfused and ischemic tissues; resulting in ischemic areas becoming less conspicuous. Through application of the proposed simple extrapolation technique, CBF biases are reduced when missing high-frequency signal components in the MR data removed during deconvolution noise stabilization are restored. The extrapolation approach was compared with other methods and showed a statistically significant increase in image contrast in CBF maps between normal and ischemic tissues for white matter (P<.05) and performed better than most other methods for gray matter. Receiver operator characteristic curve analysis demonstrated that extrapolated CBF maps better-detected penumbral regions. Extrapolated CBF maps provided more accurate CBF estimates in simulations, suggesting that the approach may provide a better prediction of outcome in the absence of treatment.

  10. Impedance, AC conductivity and dielectric behavior Adeninium Trichloromercurate (II)

    NASA Astrophysics Data System (ADS)

    Fersi, M. Amine; Chaabane, I.; Gargouri, M.

    2016-09-01

    In this work, we report the measurements impedance spectroscopy technique for the organic-inorganic hybrid compound (C5H6N5) HgCl3, 11/2H2O measured in the 209 Hz-5 MHz frequency range from 378 to 428 K. Besides, the Cole-Cole (Z″ versus Z‧) plots were well fitted to an equivalent circuit built up by a parallel combination of resistance (R), fractal capacitance (CPE) and capacitance (C). Furthermore, the AC conductivity was investigated as a function of temperature and frequency in the same range. The experiment results indicated that AC conductivity (σac) was proportional to σdc + A ωS . The obtained results are discussed in terms of the correlated barrier hopping (CBH) model. An agreement between the experimental and theoretical results suggests that the AC conductivity behavior of Adeninium Trichloromercurate (II) can be successfully explained by CBH model. The contribution of single polaron hopping to AC conductivity in a present alloy was also studied.

  11. Mycolic Acid Index Susceptibility Method for Mycobacterium tuberculosis

    PubMed Central

    Viader-Salvadó, José M.; Garza-González, Elvira; Valdez-Leal, Ramón; de los Angeles del Bosque-Moncayo, M.; Tijerina-Menchaca, Rolando; Guerrero-Olazarán, Martha

    2001-01-01

    A rapid drug susceptibility test to measure the susceptibility of Mycobacterium tuberculosis to isoniazid (INH) and rifampin (RIF) using clinical isolates and a newly defined mycolic acid index (MAI) was evaluated. A total of 200 clinical isolates of M. tuberculosis were tested for susceptibility or resistance to INH and RIF by the MAI susceptibility and indirect-proportion methods. Overall, there was agreement between the two methods for 398 (99.5%) of the 400 total tests. Specifically, the sensitivity of the MAI susceptibility method for INH and RIF was 97.6 and 100%, respectively. The specificity and positive predictive value were 100% for both drugs, and the negative predictive value for INH and RIF was 98.3 and 100%, respectively. In conclusion, the MAI susceptibility method described here can be used for rapid drug susceptibility testing of M. tuberculosis clinical isolates within 5 days after clinical isolates are incubated in the presence or absence of an antituberculosis drug. PMID:11427584

  12. Paleocurrent direction measurements in a volcanic setting by means of anisotropy of magnetic susceptibility: A case study from the Lower Miocene Tepoztlán Formation (Transmexican Volcanic Belt, Central Mexico)

    NASA Astrophysics Data System (ADS)

    Lenhardt, Nils; Böhnel, Harald; Hinderer, Matthias; Hornung, Jens

    2013-05-01

    Sources of ancient volcanic rocks are often unknown if they are either eroded and/or covered by younger deposits. This problem, as well as the provenance of reworked volcaniclastic, fluvial and mass-flow deposits, can be partially solved by the application of anisotropy of the magnetic susceptibility (AMS). For massive and poorly sorted volcaniclastic rocks in particular this may be the only way of finding reliable transport directions and therefore allowing for paleogeographic reconstructions. Here, we present a data set of 428 AMS measurements and 249 measurements of sedimentary paleocurrent indicators from the Miocene Tepoztlán Formation at the southern edge of the Transmexican Volcanic Belt (Central Mexico). The highest degree of reliability of AMS measurements is gained for data from lava samples and the lowest from mass flows. Sedimentary structures in sandstones and conglomerates such as trough cross-stratification, asymmetric ripple marks, and the shape of scours and channels could be used to calibrate the results from AMS data and to prove their reliability. AMS data on fluvial deposits point to a drainage system with a W-E flow direction, indicating an outflow of the river system into the ancient Gulf of Mexico.

  13. Investigation of microflow reversal by ac electrokinetics in orthogonal electrodes for micropump design.

    PubMed

    Yang, Kai; Wu, Jie

    2008-04-04

    Orthogonal electrodes have been reported to produce high velocity microflows when excited by ac signals, showing potential for micropumping applications. This paper investigates the microflow reversal phenomena in such orthogonal electrode micropumps. Three types of microflow fields were observed by changing the applied electric signals. Three ac electrokinetic processes, capacitive electrode polarization, Faradaic polarization, and the ac electrothermal effect, are proposed to explain the different flow patterns, respectively. The hypotheses were corroborated by impedance analysis, numerical simulations, and velocity measurements. The investigation of microflow reversal can improve the understanding of ac electrokinetics and hence effectively manipulate fluids.

  14. AC conductivity of a niobium thin film in a swept magnetic field.

    PubMed

    Tsindlekht, M I; Genkin, V M; Gazi, S; Chromik, S

    2013-02-27

    We report results of measurements of the ac conductivity of a Nb superconducting thin film in a swept dc magnetic field. In the mixed state the swept dc field creates vortices at the film surface which pass through the film and form the observed ac conductivity. Vortex rate generation does not depend on the value of the dc field and there is a large plateau-like region of dc magnetic fields where the dissipation is approximately constant. A proposed phenomenological model describes quite well the main features of the ac response in these fields, including its dependency on the sweep rate, ac amplitude, frequency, and value of the second and third harmonics.

  15. The effects of 137Cs and 60Co γ radiation on the magnetic susceptibility of BSCCO textured thin rods

    NASA Astrophysics Data System (ADS)

    Leyva, A.; Cruz, C. M.; Mora, M.; Shtejer, K.; Diez, J. C.; Angurel, L. A.; Piñera, I.; Abreu, Y.

    2005-09-01

    Bi 2Sr 2CaCu 2O x superconducting thin rods textured by the laser floating zone melting method were irradiated with 1250 and 662 keV γ rays. The behavior of some of its superconducting properties with the exposure dose was studied by the measurement of dynamic magnetic susceptibility. It was observed that, for different dose levels according to the energy of the incident radiation, the rods preserve their superconducting intragrain properties, evidencing the high resistance of the material to the γ radiation damage. In all the cases it was verified that, with increasing exposure dose, the onset temperature of the superconducting transition increases. The possible mechanisms that should take place are analyzed in the text. The χac measurements also show the increasing behavior of the superconducting volume fraction in the sample with the exposure dose.

  16. ACS Nearby Galaxy Survey

    NASA Astrophysics Data System (ADS)

    Dalcanton, Julianne

    2006-07-01

    Existing HST observations of nearby galaxies comprise a sparse and highly non-uniform archive, making comprehensive comparative studies among galaxies essentially impossible. We propose to secure HST's lasting impact on the study of nearby galaxies by undertaking a systematic, complete, and carefully crafted imaging survey of ALL galaxies in the Local Universe outside the Local Group. The resulting images will allow unprecedented measurements of: {1} the star formation history {SFH} of a >100 Mpc^3 volume of the Universe with a time resolution of Delta[log{t}]=0.25; {2} correlations between spatially resolved SFHs and environment; {3} the structure and properties of thick disks and stellar halos; and {4} the color distributions, sizes, and specific frequencies of globular and disk clusters as a function of galaxy mass and environment. To reach these goals, we will use a combination of wide-field tiling and pointed deep imaging to obtain uniform data on all 72 galaxies within a volume-limited sample extending to 3.5 Mpc, with an extension to the M81 group. For each galaxy, the wide-field imaging will cover out to 1.5 times the optical radius and will reach photometric depths of at least 2 magnitudes below the tip of the red giant branch throughout the limits of the survey volume. One additional deep pointing per galaxy will reach SNR 10 for red clump stars, sufficient to recover the ancient SFH from the color-magnitude diagram. This proposal will produce photometric information for 100 million stars {comparable to the number in the SDSS survey} and uniform multi-color images of half a square degree of sky. The resulting archive will establish the fundamental optical database for nearby galaxies, in preparation for the shift of high-resolution imaging to the near-infrared.

  17. Sustainable AC/AC hybrid electrochemical capacitors in aqueous electrolyte approaching the performance of organic systems

    NASA Astrophysics Data System (ADS)

    Abbas, Qamar; Babuchowska, Paulina; Frąckowiak, Elżbieta; Béguin, François

    2016-09-01

    A high energy hybrid AC/AC electrochemical capacitor has been realized in aqueous Li2SO4+KI electrolyte mixture. Owing to the redox processes associated with the 2I-/I2 system, the positive electrode operates in narrow potential range and displays high capacity. During prolonged potentiostatic floating at 1.6 V, the hybrid cell demonstrates remarkably stable capacitance and resistance. Analyses by temperature programmed desorption after floating at 1.6 V proved that oxidation of the positive AC electrode is prevented by the use of Li2SO4+KI, which enables the maximum potential of this electrode to be shifted below the water oxidation potential. When charged at 0.2 A g-1 up to U = 1.6 V, the hybrid cell displays a high capacitance of 75 F g-1 (300 F g-1 per mass of one electrode) compared to 47 F g-1 (188 F g-1 per mass of one electrode) for a symmetric cell in Li2SO4. At 0.2 A g-1 up to 1.6 V, the hybrid capacitor in Li2SO4+KI displays an energy density of 26 Wh kg-1 which approaches the energy density of 30.9 Wh kg-1 measured when the same carbon is implemented in a capacitor using TEABF4/ACN electrolyte and charged up to 2.5 V.

  18. The dynamic process of atmospheric water sorption in [EMIM][Ac] and mixtures of [EMIM][Ac] with biopolymers and CO2 capture in these systems.

    PubMed

    Chen, Yu; Sun, Xiaofu; Yan, Chuanyu; Cao, Yuanyuan; Mu, Tiancheng

    2014-10-02

    There are mainly three findings related to the dynamic process of atmospheric water sorption in the ionic liquid (IL) 1-ethyl-3-methlyl-imidazolium acetate ([EMIM][Ac]) and its mixtures with biopolymers (i.e., cellulose, chitin, and chitosan), and CO2 capture in these systems above. The analytical methods mainly include gravimetric hygroscopicity measurement and in situ infrared spectroscopy with the techniques of difference, derivative, deconvoluted attenuated total reflectance and two-dimensional correlation. These three findings are listed as below. (1) Pure [EMIM][Ac] only shows a two-regime pattern, while all the mixtures of [EMIM][Ac] with biopolymers (i.e., cellulose, chitin, and chitosan) present a three-regime tendency for the dynamic process of atmospheric water sorption. Specifically, the IL/chitosan mixture has a clear three-regime mode; the [EMIM][Ac]/chitin mixture has an unclear indiscernible regime 3; and the [EMIM][Ac]/cellulose mixture shows an indiscernible regime 2. (2) [EMIM][Ac] and its mixtures with biopolymers could physically absorb a trace amount of and chemically react with a much larger amount of CO2 from the air. The chemisorption capacity of CO2 in these pure and mixed systems is ordered as chitosan/[EMIM][Ac] mixture > chitin/[EMIM][Ac] mixture > cellulose/[EMIM][Ac] mixture > pure [EMIM][Ac] (ca. 0.09 mass ratio % g/g CO2/IL). (3) The CO2 solubility in [EMIM][Ac] decreases about 50% after being exposed to the atmospheric moist air for some specific time period.

  19. Watts Up? Pro AC Power Meter for Automated Energy Recording

    PubMed Central

    Hirst, Jason M.; Miller, Jonathan R.; Kaplan, Brent A.; Reed, Derek D.

    2013-01-01

    The purpose of the present paper is to review the Watts up? Pro AC power meter. Evaluations of the meter's reliability for measuring energy consumption by consumer electronics yielded acceptable levels of reliability. Implications and limitations for the use of this product in behavior analytic research and practice are discussed.

  20. Equivalent Circuits For AC-Impedance Analysis Of Corrosion

    NASA Technical Reports Server (NTRS)

    Danford, M. D.

    1992-01-01

    Report presents investigation of equivalent circuits for ac-impedance analysis of corrosion. Impedance between specimen and electrolyte measured as function of frequency. Data used to characterize corrosion electrochemical system in terms of equivalent circuit. Eleven resistor/capacitor equivalent-circuit models were analyzed.

  1. AC and Phase Sensing of Nanowires for Biosensing

    PubMed Central

    Crescentini, Marco; Rossi, Michele; Ashburn, Peter; Lombardini, Marta; Sangiorgi, Enrico; Morgan, Hywel; Tartagni, Marco

    2016-01-01

    Silicon nanowires are label-free sensors that allow real-time measurements. They are economical and pave the road for point-of-care applications but require complex readout and skilled personnel. We propose a new model and technique for sensing nanowire sensors using alternating currents (AC) to capture both magnitude and phase information from the sensor. This approach combines the advantages of complex impedance spectroscopy with the noise reduction performances of lock-in techniques. Experimental results show how modifications of the sensors with different surface chemistries lead to the same direct-current (DC) response but can be discerned using the AC approach. PMID:27104577

  2. Simultaneous distribution of AC and DC power

    DOEpatents

    Polese, Luigi Gentile

    2015-09-15

    A system and method for the transport and distribution of both AC (alternating current) power and DC (direct current) power over wiring infrastructure normally used for distributing AC power only, for example, residential and/or commercial buildings' electrical wires is disclosed and taught. The system and method permits the combining of AC and DC power sources and the simultaneous distribution of the resulting power over the same wiring. At the utilization site a complementary device permits the separation of the DC power from the AC power and their reconstruction, for use in conventional AC-only and DC-only devices.

  3. Magnetic Susceptibility of Wet vs. Dry Sediment and Mass Normalized vs. Volume Normalized Magnetic Susceptibility

    NASA Astrophysics Data System (ADS)

    Kletetschka, G.; Hruba, J.; Nabelek, L.

    2015-12-01

    The measurement of magnetic susceptibility in sediments represents a fast and non-destructive technique that can be used to deduce the concentration of magnetic minerals [1, 2]. Magnetic minerals change their magnetic properties with temperature [3]. Heating (during a fire, laboratory, with the purpose of manufacturing a product, etc.) can modify a number of sediment properties [4, 5]. Heat-induced sediment mineralogical changes may cause irreversible changes in the sediment mineral structure and composition, and they occur at a wide range of temperature [6]. We provided measurements of magnetic susceptibility on samples from the Stara Jimka (SJ) paleo lacustrine site in the Bohemian Forest using magnetic susceptibility meter MS-30. Sediment samples of approximately 0.2 cm thickness were weighed and put into plastic containers. First, measurements of magnetic susceptibility were taken on wet samples. Then the containers were put into the oven and sediment was dried at temperature of 110°C. After drying and cooling to room temperature, measurements of magnetic susceptibility were repeated. Dry samples were also weighed. Comparison of magnetic susceptibility of dry versus wet samples showed higher values of magnetic susceptibility of dry samples. This enhancement was probably caused during oven-drying, when constituents of sediment (mainly clays) underwent heat-induced changes. We also compared volume normalized values of magnetic susceptibility with mass normalized values. Mass normalized magnetic susceptibility was burdened by greater noise. References: [1] QUIJANO, L. et al. 2001. Magnetic Susceptibilty in Topsoils and Bulk Cores of Cultivated Calcisols. [2] DEARING, J. A. 1994. Environmental Magnetic Susceptibility. [3] HANESCH, M. and SCHOLGER, R. 2005. The Influence of Soil Type on the Magnetic Susceptibility Measured throughout Soil Profiles. [4] FARWIG, V. J. et al. 2004. The Effects of Heating on Mineral Magnetic Enhancement of Soils. [5] KLETETSCHKA, G

  4. Different susceptibilities of Eimeria acervulina, Eimeria maxima, and Eimeria tenella oocysts to dessication

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Outbreaks of avian coccidiosis may occur when susceptible chickens are raised on litter containing high concentrations of viable Eimeria oocysts. The purpose of this study was to compare the relative sensitivities of E. acervulina, E. maxima, and E. tenella oocysts to dessication. Sporulated E. ac...

  5. Study on Bt Susceptibility and Resistance Mechanisms in the Sugarcane Borer, Diatraea saccharalis

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Dose response and growth inhibition of Cry1Ab-susceptible and -resistant strains of the sugarcane borer, Diatraea saccharalis, were evaluated with Cry1Aa and Cry1Ac toxins. The median lethal concentration (LC50) of the Cry1Ab-resistant strain was estimated to be >80- and 45-fold greater than that of...

  6. Marijuana Usage and Hypnotic Susceptibility

    ERIC Educational Resources Information Center

    Franzini, Louis R.; McDonald, Roy D.

    1973-01-01

    Anonymous self-reported drug usage data and hypnotic susceptibility scores were obtained from 282 college students. Frequent marijuana users (more than 10 times) showed greater susceptibility to hypnosis than nonusers. (Author)

  7. Modeling and Correcting the Time-Dependent ACS PSF

    NASA Technical Reports Server (NTRS)

    Rhodes, Jason; Massey, Richard; Albert, Justin; Taylor, James E.; Koekemoer, Anton M.; Leauthaud, Alexie

    2006-01-01

    The ability to accurately measure the shapes of faint objects in images taken with the Advanced Camera for Surveys (ACS) on the Hubble Space Telescope (HST) depends upon detailed knowledge of the Point Spread Function (PSF). We show that thermal fluctuations cause the PSF of the ACS Wide Field Camera (WFC) to vary over time. We describe a modified version of the TinyTim PSF modeling software to create artificial grids of stars across the ACS field of view at a range of telescope focus values. These models closely resemble the stars in real ACS images. Using 10 bright stars in a real image, we have been able to measure HST s apparent focus at the time of the exposure. TinyTim can then be used to model the PSF at any position on the ACS field of view. This obviates the need for images of dense stellar fields at different focus values, or interpolation between the few observed stars. We show that residual differences between our TinyTim models and real data are likely due to the effects of Charge Transfer Efficiency (CTE) degradation. Furthermore, we discuss stochastic noise that is added to the shape of point sources when distortion is removed, and we present MultiDrizzle parameters that are optimal for weak lensing science. Specifically, we find that reducing the MultiDrizzle output pixel scale and choosing a Gaussian kernel significantly stabilizes the resulting PSF after image combination, while still eliminating cosmic rays/bad pixels, and correcting the large geometric distortion in the ACS. We discuss future plans, which include more detailed study of the effects of CTE degradation on object shapes and releasing our TinyTim models to the astronomical community.

  8. The Rapid Induction Susceptibility Scale.

    ERIC Educational Resources Information Center

    Page, Roger A.; Handley, George W.

    1989-01-01

    Developed Rapid Induction Susceptibility Scale using Chiasson induction to produce hypnotic susceptibility scale which is quickly administered and yields scores comparable to the Stanford Hypnotic Susceptibility Scale, Form C (SHSS:C). Found that validation study with college students (N=100) produced a correlation of .88 with the SHSS:C and…

  9. Space charge and charge trapping characteristics of cross-linked polyethylene subjected to ac electric stresses

    NASA Astrophysics Data System (ADS)

    Chong, Y. L.; Chen, G.; Miyake, H.; Matsui, K.; Tanaka, Y.; Takada, T.

    2006-04-01

    This paper reports on the result of space charge evolution in cross-linked polyethylene (XLPE) planar samples approximately 220 µm thick. The space charge measurement technique used in this study is the pulsed electroacoustic method. There are two phases to this experiment. In the first phase, the samples were subjected to dc 30 kVdc mm-1 and ac (sinusoidal) electric stress levels of 30 kVpk mm-1 at frequencies of 1, 10 and 50 Hz ac. In addition, ac space charge under 30 kVrms mm-1 and 60 kVpk mm-1 electric stress at 50 Hz was also investigated. The volts-off results showed that the amount of charge trapped in XLPE sample under dc electric stress is significantly bigger than samples under ac stress even when the applied ac stresses are substantially higher. The second phase of the experiment involves studying the dc space charge evolution in samples that were tested under ac stress during the first phase of the experiment. Ac ageing causes positive charge to become more dominant over negative charge. It was also discovered that ac ageing creates deeper traps, particularly for negative charge. This paper also gives a brief overview of the data processing methods used to analyse space charge under ac electric stress.

  10. APN1 is a functional receptor of Cry1Ac but not Cry2Ab in Helicoverpa zea

    PubMed Central

    Wei, Jizhen; Zhang, Min; Liang, Gemei; Wu, Kongming; Guo, Yuyuan; Ni, Xinzhi; Li, Xianchun

    2016-01-01

    Lepidopteran midgut aminopeptidases N (APNs) are phylogenetically divided into eight clusters, designated as APN1–8. Although APN1 has been implicated as one of the receptors for Cry1Ac in several species, its potential role in the mode of action of Cry2Ab has not been functionally determined so far. To test whether APN1 also acts as one of the receptors for Cry1Ac in Helicoverpa zea and even for Cry2Ab in this species, we conducted a gain of function analysis by heterologously expressing H. zea APN1 (HzAPN1) in the midgut and fat body cell lines of H. zea and the ovarian cell line of Spodoptera frugiperda (Sf9) and a loss of function analysis by RNAi (RNA interference) silencing of the endogenous APN1 in the three cell lines using the HzAPN1 double strand RNA (dsRNA). Heterologous expression of HzAPN1 significantly increased the susceptibility of the three cell lines to Cry1Ac, but had no effects on their susceptibility to Cry2Ab. Knocking down of the endogenous APN1 made the three cell lines resistant to Cry1Ac, but didn’t change cell lines susceptibility to Cry2Ab. The findings from this study demonstrate that HzAPN1 is a functional receptor of Cry1Ac, but not Cry2Ab. PMID:26755166

  11. Kinetic studies of the stress corrosion cracking of D6AC steel

    NASA Technical Reports Server (NTRS)

    Noronha, P. J.

    1975-01-01

    The effect of load interactions on the crack growth velocity of D6AC steel under stress corrosion cracking conditions was determined. The environment was a 3.5 percent salt solution. The modified-wedge opening load specimens were fatigue precracked and subjected to a deadweight loading in creep machines. The effects of load shedding on incubation times and crack growth rates were measured using high-sensitivity compliance measurement techniques. Load shedding results in an incubation time, the length of which depends on the amount of load shed and the baseline stress intensity. The sequence of unloading the specimen also controls the subsequent incubation period. The incubation period is shorter when load shedding passes through zero load than when it does not if the specimen initially had the same baseline stress intensity. The crack growth rates following the incubation period are also different from the steady-state crack growth rate at the operating stress intensity. These data show that the susceptibility of this alloy system to stress corrosion cracking depends on the plane-strain fracture toughness and on the yield strength of the material.

  12. Estimation of bonding nature using diamagnetic susceptibility.

    PubMed

    Tomiyasu, Keisuke; Sato, Toyoto; Orimo, Shin-ichi

    2015-05-21

    A chemical bond includes both covalent and ionic characteristics. We develop an experimental method to estimate the degree of each contribution based on magnetic susceptibility measurements, in which Pascal's scheme for Larmor diamagnetism is combined with electronegativity. The applicability to metal hydrides is also shown.

  13. Population screening for genetic susceptibility to disease.

    PubMed Central

    Clarke, A.

    1995-01-01

    Genetic screening for susceptibility to common diseases, such as the common cancers, cardiovascular disease, and diabetes, may soon be technically feasible. Commercial interests should not be allowed to introduce such screening before proper evaluation or without adequate counselling and support. The evaluation of such testing should include psychosocial and medical outcomes and outcomes for those given low risks as well as high risks. These tests may distract attention away from environmental factors contributing to disease, for which social and political measures may be more appropriate than individualised susceptibility screening and lifestyle modification. PMID:7613325

  14. [Rapid antibiotic susceptibility test in Clinical Microbiology].

    PubMed

    March Rosselló, Gabriel Alberto; Bratos Pérez, Miguel Ángel

    2016-01-01

    The most widely used antibiotic susceptibility testing methods in Clinical Microbiology are based on the phenotypic detection of antibiotic resistance by measuring bacterial growth in the presence of the antibiotic being tested. These conventional methods take typically 24hours to obtain results. A review is presented here of recently developed techniques for the rapid determination of antibiotic susceptibility. Data obtained with different methods such as molecular techniques, flow cytometry, chemiluminescence, mass spectrometry, commercial methods used in routine work, colorimetric methods, nephelometry, microarrays, microfluids, and methods based on cell disruption and sequencing, are analyzed and discussed in detail.

  15. [Antimicrobial susceptibility of probiotics].

    PubMed

    Xu, Jin; Liu, Xiumei; Yang, Baolan; Li, Zhigang

    2008-05-01

    The aim of our study was to analyse the antibiotic susceptibility of 31 probiotics strains, including 9 Bifidobacterium and 22 Lactobacillus used for the manufacture of various fermented foods in China. Probiotics are tested for minimum inhibitory concentrations (MIC) of 24 kinds of antibiotics by broth dilution method on cation-adjusted Mueller-Hinton broth with lysed horse blood. 31 strains of probiotics were sensitive to ampicillin, penicillin, imipenem, gentamicine, amoxicillin, amoxicillin/clavulanic acid, gatifloxacin, erythromycin, clindamycin, and resistant to nalidixic acid, vancomycine, fosfomycin.

  16. A predictive model of the temperature dependence of AC transport losses in (Bi, Pb)2Sr2Ca2Cu3Ox tapes

    NASA Astrophysics Data System (ADS)

    Zhang, Guo Min; Zhen Lin, Liang; Xiao, Li Ye; Jia Yu, Yun; Schwartz, Justin; Pamidi, Sastry V.

    2011-08-01

    Critical currents and AC losses of (Bi, Pb)2Sr2Ca2Cu3Ox superconducting tapes were measured in self-field as a function of temperature. The experimental data of the temperature dependence of critical current were compared with calculated results. An approach to calculating AC losses as a function of temperature was developed and the calculated AC losses were compared with the measured data. The study shows that AC losses at any temperature can be estimated using the model from the critical parameters or from the measured AC loss factor at a certain temperature, such as 77 K.

  17. Magnetic Susceptibility in the Vertebral Column

    NASA Astrophysics Data System (ADS)

    Schick, F.; Nagele, T.; Lutz, O.; Pfeffer, K.; Giehl, J.

    1994-01-01

    A magnetic resonance method is described which provides good-quality field-mapping images of the spine, although the in vivo signals from red bone marrow of the vertebral bodies exhibit similar fractions of lipid and water protons with their chemical-shift difference of 3.4 ppm. The susceptibilities of bone marrow and intervertebral disks were examined in 20 cadaveric human spines, 9 healthy volunteers, and 9 patients with degenerative disk alterations. The influence of geometrical properties was studied in cylindrical spine phantoms of different size and contents with different susceptibility. The measurements reveal interindividual differences of the susceptibility of the intervertebral disks in healthy subjects. Three out of nine degenerated disks with low signal in T2-weighted spin-echo images showed irregularities of the field distribution within the nucleus pulposus.

  18. Whole Brain Susceptibility Mapping Using Compressed Sensing

    PubMed Central

    Wu, Bing; Li, Wei; Guidon, Arnaud; Liu, Chunlei

    2011-01-01

    The derivation of susceptibility from image phase is hampered by the ill-conditioned filter inversion in certain k-space regions. In this paper, compressed sensing (CS) is used to compensate for the k-space regions where direct filter inversion is unstable. A significantly lower level of streaking artifacts is produced in the resulting susceptibility maps for both simulated and in vivo data sets compared to outcomes obtained using the direct threshold method. It is also demonstrated that the CS based method outperforms regularization based methods. The key difference between the regularized inversions and CS compensated inversions is that, in the former case, the entire k-space spectrum estimation is affected by the ill-conditioned filter inversion in certain k-space regions, whereas in the CS based method only the ill-conditioned k-space regions are estimated. In the susceptibility map calculated from the phase measurement obtained using a 3T scanner, not only are the iron-rich regions well depicted, but good contrast between white and gray matter interfaces that feature a low level of susceptibility variations are also obtained. The correlation between the iron content and the susceptibility levels in iron-rich deep nucleus regions is studied, and strong linear relationships are observed which agree with previous findings. PMID:21671269

  19. Role of reversible susceptibility in ferromagnetic hysteresis

    NASA Astrophysics Data System (ADS)

    Schneider, Carl S.

    2002-05-01

    An equation of state based upon saturation magnetization, Ms, coercive field, Hc, and the reversible susceptibility function of magnetization is proposed for ferromagnetic hysteresis. Reversible susceptibility divided by the initial susceptibility is the anisotropy function of magnetization, χr, ranging from one in the demagnetized state to zero at saturation, and varying with magnetic history. Its dependence on scaled magnetization, m=M/Ms on the interval (-1,1) varies with material, allowing characterization of anisotropy classes. Precise measurements have been made of reversible susceptibility, initial and saturate magnetization curves, and loops for Orthonol™, annealed 3% nickel steel and as-received 1018 steel, representing crystals, isotropic polycrystals and composite ferromagnets, respectively. Magnetization change is the product of the reversible susceptibility, change in the applied field and the cooperative function due to domain interactions. This function is 1+βm for the virgin curve with half this slope from any reversal, where β=Ms/XiHc is the hysteresis coefficient. Variation of β for 1018 steel is due to distributed coercivities, and causes sigmoid B(H) curves. In the scaled field representation, where h=H/Hc, the cooperative function is 1/(1-hχr), a hyperbolic field dependence smeared by the anisotropy function. Constant anisotropy causes closed hysteresis loops, while variable anisotropy causes creeping of cycled asymmetric loops. In ferromagnetism, 1/χ=1/χr-h, normal scaled reluctivity is reduced from its reversible value by the scaled field.

  20. Whole brain susceptibility mapping using compressed sensing.

    PubMed

    Wu, Bing; Li, Wei; Guidon, Arnaud; Liu, Chunlei

    2012-01-01

    The derivation of susceptibility from image phase is hampered by the ill-conditioned filter inversion in certain k-space regions. In this article, compressed sensing is used to compensate for the k-space regions where direct filter inversion is unstable. A significantly lower level of streaking artifacts is produced in the resulting susceptibility maps for both simulated and in vivo data sets compared to outcomes obtained using the direct threshold method. It is also demonstrated that the compressed sensing based method outperforms regularization based methods. The key difference between the regularized inversions and compressed sensing compensated inversions is that, in the former case, the entire k-space spectrum estimation is affected by the ill-conditioned filter inversion in certain k-space regions, whereas in the compressed sensing based method only the ill-conditioned k-space regions are estimated. In the susceptibility map calculated from the phase measurement obtained using a 3T scanner, not only are the iron-rich regions well depicted, but good contrast between white and gray matter interfaces that feature a low level of susceptibility variations are also obtained. The correlation between the iron content and the susceptibility levels in iron-rich deep nucleus regions is studied, and strong linear relationships are observed which agree with previous findings.

  1. Dielectric relaxation in AC powder electroluminescent devices

    NASA Astrophysics Data System (ADS)

    Zhang, Shuai; Su, Haibin; Tan, Chuan Seng; Wong, Terence Kin Shun; Teo, Ronnie Jin Wah

    2017-01-01

    The dielectric properties of AC powder electroluminescent devices were measured and analyzed using complex impedance spectroscopy to determine the relaxation processes occurring within the devices. The relaxation processes identified were ascribed to the electrode polarization caused by ion accumulation at the electrode/resin interfaces, the Maxwell-Wagner-Sillars effects at the (ZnS or BaTiO3) particle/resin interfaces, and the dipolar reorientation of polymer chains in the resin matrix. Each relaxation process was represented by its corresponding equivalent circuit component. Space charge polarization at the electrodes were represented by a Warburg element, a resistor, and a constant phase element. The resin matrix, ZnS/resin and BaTiO3/resin interfaces could each be modeled by a resistor and a capacitor in parallel. The simulated equivalent circuits for three different printed structures showed good fitting with their experimental impedance results.

  2. Association between the -794 (CATT)5-8  MIF gene polymorphism and susceptibility to acute coronary syndrome in a western Mexican population.

    PubMed

    Valdés-Alvarado, Emmanuel; Muñoz-Valle, José Francisco; Valle, Yeminia; Sandoval-Pinto, Elena; García-González, Ilian Janet; Valdez-Haro, Angélica; De la Cruz-Mosso, Ulises; Flores-Salinas, Héctor Enrique; Padilla-Gutiérrez, Jorgé Ramón

    2014-01-01

    The macrophage migration inhibitory factor (MIF) is related to the progression of atherosclerosis, which, in turn, is a key factor in the development of acute coronary syndrome (ACS). MIF has a CATT short tandem repeat (STR) at position -794 that might be involved in its expression rate. The aim of this study was to investigate the association between the -794 (CATT)5-8  MIF gene polymorphism and susceptibility to ACS in a western Mexican population. This research included 200 ACS patients classified according to the criteria of the American College of Cardiology (ACC) and 200 healthy subjects (HS). The -794 (CATT)5-8  MIF gene polymorphism was analyzed using a conventional polymerase chain reaction (PCR) technique. The 6 allele was the most frequent in both groups (ACS: 54% and HS: 57%). The most common genotypes in ACS patients and HS were 6/7 and 6/6, respectively, and a significant association was found between the 6/7 genotype and susceptibility to ACS (68% versus 47% in ACS and HS, resp., P = 0.03). We conclude that the 6/7 genotype of the MIF -794 (CATT)5-8 polymorphism is associated with susceptibility to ACS in a western Mexican population.

  3. Association between the −794 (CATT)5–8  MIF Gene Polymorphism and Susceptibility to Acute Coronary Syndrome in a Western Mexican Population

    PubMed Central

    Valdés-Alvarado, Emmanuel; Muñoz-Valle, José Francisco; Valle, Yeminia; Sandoval-Pinto, Elena; García-González, Ilian Janet; Valdez-Haro, Angélica; Flores-Salinas, Héctor Enrique; Padilla-Gutiérrez, Jorgé Ramón

    2014-01-01

    The macrophage migration inhibitory factor (MIF) is related to the progression of atherosclerosis, which, in turn, is a key factor in the development of acute coronary syndrome (ACS). MIF has a CATT short tandem repeat (STR) at position −794 that might be involved in its expression rate. The aim of this study was to investigate the association between the −794 (CATT)5–8  MIF gene polymorphism and susceptibility to ACS in a western Mexican population. This research included 200 ACS patients classified according to the criteria of the American College of Cardiology (ACC) and 200 healthy subjects (HS). The −794 (CATT)5–8  MIF gene polymorphism was analyzed using a conventional polymerase chain reaction (PCR) technique. The 6 allele was the most frequent in both groups (ACS: 54% and HS: 57%). The most common genotypes in ACS patients and HS were 6/7 and 6/6, respectively, and a significant association was found between the 6/7 genotype and susceptibility to ACS (68% versus 47% in ACS and HS, resp., P = 0.03). We conclude that the 6/7 genotype of the MIF −794 (CATT)5–8 polymorphism is associated with susceptibility to ACS in a western Mexican population. PMID:25105152

  4. Effect of the magnetic material on AC losses in HTS conductors in AC magnetic field carrying AC transport current

    NASA Astrophysics Data System (ADS)

    Wan, Xing-Xing; Huang, Chen-Guang; Yong, Hua-Dong; Zhou, You-He

    2015-11-01

    This paper presents an investigation on the AC losses in several typical superconducting composite conductors using the H-formulation model. A single superconducting strip with ferromagnetic substrate or cores and a stack of coated conductors with ferromagnetic substrates are studied. We consider all the coated conductors carrying AC transport currents and simultaneously exposed to perpendicular AC magnetic fields. The influences of the amplitude, frequency, phase difference and ferromagnetic materials on the AC losses are investigated. The results show that the magnetization losses of single strip and stacked strips have similar characteristics. The ferromagnetic substrate can increase the magnetization loss at low magnetic field, and decrease the loss at high magnetic field. The ferromagnetic substrate can obviously increase the transport loss in stacked strips. The trends of total AC losses of single strip and stacked strips are similar when they are carrying current or exposed to a perpendicular magnetic field. The effect of the frequency on the total AC losses of single strip is related to the amplitude of magnetic field. The AC losses decrease with increasing frequency in low magnetic field region while increase in high magnetic field region. As the phase difference changes, there is a periodic variation for the AC losses. Moreover, when the strip is under only the transport current and magnetic field, the ferromagnetic cores will increase the AC losses for large transport current or field.

  5. Quantitative Susceptibility Mapping in Parkinson's Disease

    PubMed Central

    Seiler, Stephan; Deistung, Andreas; Schweser, Ferdinand; Franthal, Sebastian; Homayoon, Nina; Katschnig-Winter, Petra; Koegl-Wallner, Mariella; Pendl, Tamara; Stoegerer, Eva Maria; Wenzel, Karoline; Fazekas, Franz; Ropele, Stefan; Reichenbach, Jürgen Rainer; Schmidt, Reinhold; Schwingenschuh, Petra

    2016-01-01

    Background Quantitative susceptibility mapping (QSM) and R2* relaxation rate mapping have demonstrated increased iron deposition in the substantia nigra of patients with idiopathic Parkinson’s disease (PD). However, the findings in other subcortical deep gray matter nuclei are converse and the sensitivity of QSM and R2* for morphological changes and their relation to clinical measures of disease severity has so far been investigated only sparsely. Methods The local ethics committee approved this study and all subjects gave written informed consent. 66 patients with idiopathic Parkinson’s disease and 58 control subjects underwent quantitative MRI at 3T. Susceptibility and R2* maps were reconstructed from a spoiled multi-echo 3D gradient echo sequence. Mean susceptibilities and R2* rates were measured in subcortical deep gray matter nuclei and compared between patients with PD and controls as well as related to clinical variables. Results Compared to control subjects, patients with PD had increased R2* values in the substantia nigra. QSM also showed higher susceptibilities in patients with PD in substantia nigra, in the nucleus ruber, thalamus, and globus pallidus. Magnetic susceptibility of several of these structures was correlated with the levodopa-equivalent daily dose (LEDD) and clinical markers of motor and non-motor disease severity (total MDS-UPDRS, MDS-UPDRS-I and II). Disease severity as assessed by the Hoehn & Yahr scale was correlated with magnetic susceptibility in the substantia nigra. Conclusion The established finding of higher R2* rates in the substantia nigra was extended by QSM showing superior sensitivity for PD-related tissue changes in nigrostriatal dopaminergic pathways. QSM additionally reflected the levodopa-dosage and disease severity. These results suggest a more widespread pathologic involvement and QSM as a novel means for its investigation, more sensitive than current MRI techniques. PMID:27598250

  6. Alate susceptibility in ants

    PubMed Central

    Ho, Eddie K H; Frederickson, Megan E

    2014-01-01

    Pathogens are predicted to pose a particular threat to eusocial insects because infections can spread rapidly in colonies with high densities of closely related individuals. In ants, there are two major castes: workers and reproductives. Sterile workers receive no direct benefit from investing in immunity, but can gain indirect fitness benefits if their immunity aids the survival of their fertile siblings. Virgin reproductives (alates), on the other hand, may be able to increase their investment in reproduction, rather than in immunity, because of the protection they receive from workers. Thus, we expect colonies to have highly immune workers, but relatively more susceptible alates. We examined the survival of workers, gynes, and males of nine ant species collected in Peru and Canada when exposed to the entomopathogenic fungus Beauveria bassiana. For the seven species in which treatment with B. bassiana increased ant mortality relative to controls, we found workers were significantly less susceptible compared with both alate sexes. Female and male alates did not differ significantly in their immunocompetence. Our results suggest that, as with other nonreproductive tasks in ant colonies like foraging and nest maintenance, workers have primary responsibility for colony immunity, allowing alates to specialize on reproduction. We highlight the importance of colony-level selection on individual immunity in ants and other eusocial organisms. PMID:25540683

  7. Magnetic susceptibilities of minerals

    USGS Publications Warehouse

    Rosenblum, Sam; Brownfield, I.K.

    2000-01-01

    Magnetic separation of minerals is a topic that is seldom reported in the literature for two reasons. First, separation data generally are byproducts of other projects; and second, this study requires a large amount of patience and is unusually tedious. Indeed, we suspect that most minerals probably are never investigated for this property. These data are timesaving for mineralogists who concentrate mono-mineralic fractions for chemical analysis, age dating, and for other purposes. The data can certainly be used in the ore-beneficiation industries. In some instances, magnetic-susceptibility data may help in mineral identification, where other information is insufficient. In past studies of magnetic separation of minerals, (Gaudin and Spedden, 1943; Tille and Kirkpatrick, 1956; Rosenblum, 1958; Rubinstein and others, 1958; Flinter, 1959; Hess, 1959; Baker, 1962; Meric and Peyre, 1963; Rojas and others, 1965; and Duchesne, 1966), the emphasis has been on the ferromagnetic and paramagnetic ranges of extraction. For readers interested in the history of magnetic separation of minerals, Krumbein and Pettijohn (1938, p. 344-346) indicated nine references back to 1848. The primary purpose of this paper is to report the magnetic-susceptibility data on as many minerals as possible, similar to tables of hardness, specific gravity, refractive indices, and other basic physical properties of minerals. A secondary purpose is to demonstrate that the total and best extraction ranges are influenced by the chemistry of the minerals. The following notes are offered to help avoid problems in separating a desired mineral concentrate from mixtures of mineral grains.

  8. Total AC loss study of 2G HTS coils for fully HTS machine applications

    NASA Astrophysics Data System (ADS)

    Zhang, Min; Yuan, Weijia; Kvitkovic, Jozef; Pamidi, Sastry

    2015-11-01

    The application of HTS coils for fully HTS machines has become a new research focus. In the stator of an electrical machine, HTS coils are subjected to a combination of an AC applied current and AC external magnetic field. There is a phase shift between the AC current and AC magnetic field. In order to understand and estimate the total AC loss of HTS coils for electrical machines, we designed and performed a calorimetric measurement for a 2G HTS racetrack coil. Our measurement indicates that the total AC loss is greatly influenced by the phase shift between the applied current and the external magnetic field when the magnetic field is perpendicular to the tape surface. When the applied current and the external magnetic field are in phase, the total AC loss is the highest. When there is a 90 degree phase difference, the total AC loss is the lowest. In order to explain this phenomenon, we employ H formulation and finite element method to model the 2G HTS racetrack coil. Our calculation agrees well with experimental measurements. Two parameters are defined to describe the modulation of the total AC loss in terms of phase difference. The calculation further reveals that the influence of phase difference varies with magnetic field direction. The greatest influence of phase difference is in the perpendicular direction. The study provides key information for large-scale 2G HTS applications, e.g. fully HTS machines and superconducting magnetic energy storage, where the total AC loss subjected to both applied currents and external magnetic fields is a critical parameter for the design.

  9. ac electroosmosis in rectangular microchannels.

    PubMed

    Campisi, Michele; Accoto, Dino; Dario, Paolo

    2005-11-22

    Motivated by the growing interest in ac electroosmosis as a reliable no moving parts strategy to control fluid motion in microfluidic devices for biomedical applications, such as lab-on-a-chip, we study transient and steady-state electrokinetic phenomena (electroosmosis and streaming currents) in infinitely extended rectangular charged microchannels. With the aid of Fourier series and Laplace transforms we provide a general formal solution of the problem, which is used to study the time-dependent response to sudden ac applied voltage differences in case of finite electric double layer. The Debye-Huckel approximation has been adopted to allow for an algebraic solution of the Poisson-Boltzmann problem in Fourier space. We obtain the expressions of flow velocity profiles, flow rates, streaming currents, as well as expressions of the complex hydraulic and electrokinetic conductances. We analyze in detail the dependence of the electrokinetic conductance on the extension of linear dimensions relative to the Debye length, with an eye on finite electric double layer effects.

  10. ACS PSF Variations with Temperatures

    NASA Astrophysics Data System (ADS)

    Sahu, Kailash C.; Lallo, Matt; Makidon, Russ

    2007-09-01

    We have used the HST ACS/WFC observations of a Galactic bulge field taken over a continuous interval of 7 days (Prop 9750) to investigate the possible dependence of the ACS focus with the external temperatures. This dataset allows us to investigate possible focus variations over timescales of a few hours to a few days. The engineering data related to the external temperatures for this duration show that the maximum temperature change occurred over the first 1.5 days. Among all the different temperatures recorded, the truss diametric differential and the truss axial temperatures are the only two temperatures which have the same timescale of variation as the PSFwidth variations. The PSF-widths also strongly correlate with these two temperatures during this time interval. We empirically fit the PSF-width variations with these 2 temperature sensor values. This suggests that the focus has a similar dependence, and we recommend that this finding be followed up with the determination of actual focus values to check if the focus values indeed have the same correlation. If so, the temperature data can be useful in estimating the focus values, which can then be used to predict the PSFs to a first order.

  11. ac electroosmosis in rectangular microchannels

    NASA Astrophysics Data System (ADS)

    Campisi, Michele; Accoto, Dino; Dario, Paolo

    2005-11-01

    Motivated by the growing interest in ac electroosmosis as a reliable no moving parts strategy to control fluid motion in microfluidic devices for biomedical applications, such as lab-on-a-chip, we study transient and steady-state electrokinetic phenomena (electroosmosis and streaming currents) in infinitely extended rectangular charged microchannels. With the aid of Fourier series and Laplace transforms we provide a general formal solution of the problem, which is used to study the time-dependent response to sudden ac applied voltage differences in case of finite electric double layer. The Debye-Hückel approximation has been adopted to allow for an algebraic solution of the Poisson-Boltzmann problem in Fourier space. We obtain the expressions of flow velocity profiles, flow rates, streaming currents, as well as expressions of the complex hydraulic and electrokinetic conductances. We analyze in detail the dependence of the electrokinetic conductance on the extension of linear dimensions relative to the Debye length, with an eye on finite electric double layer effects.

  12. RHIC spin flipper AC dipole controller

    SciTech Connect

    Oddo, P.; Bai, M.; Dawson, C.; Gassner, D.; Harvey, M.; Hayes, T.; Mernick, K.; Minty, M.; Roser, T.; Severino, F.; Smith, K.

    2011-03-28

    The RHIC Spin Flipper's five high-Q AC dipoles which are driven by a swept frequency waveform require precise control of phase and amplitude during the sweep. This control is achieved using FPGA based feedback controllers. Multiple feedback loops are used to and dynamically tune the magnets. The current implementation and results will be presented. Work on a new spin flipper for RHIC (Relativistic Heavy Ion Collider) incorporating multiple dynamically tuned high-Q AC-dipoles has been developed for RHIC spin-physics experiments. A spin flipper is needed to cancel systematic errors by reversing the spin direction of the two colliding beams multiple times during a store. The spin flipper system consists of four DC-dipole magnets (spin rotators) and five AC-dipole magnets. Multiple AC-dipoles are needed to localize the driven coherent betatron oscillation inside the spin flipper. Operationally the AC-dipoles form two swept frequency bumps that minimize the effect of the AC-dipole dipoles outside of the spin flipper. Both AC bumps operate at the same frequency, but are phase shifted from each other. The AC-dipoles therefore require precise control over amplitude and phase making the implementation of the AC-dipole controller the central challenge.

  13. Residential Proximity to Major Roadways is Associated with Increased Levels of AC133+ Circulating Angiogenic Cells

    PubMed Central

    DeJarnett, Natasha; Yeager, Ray; Conklin, Daniel J.; Lee, Jongmin; O'Toole, Timothy E.; McCracken, James; Abplanalp, Wes; Srivastava, Sanjay; Riggs, Daniel W.; Hamzeh, Ihab; Wagner, Stephen; Chugh, Atul; DeFilippis, Andrew; Ciszewski, Tiffany; Wyatt, Brad; Becher, Carrie; Higdon, Deirdre; Ramos, Kenneth S.; Tollerud, David J.; Myers, John A.; Rai, Shesh N.; Shah, Jasmit; Zafar, Nagma; Krishnasamy, Sathya S.; Prabhu, Sumanth D.; Bhatnagar, Aruni

    2016-01-01

    Objective Previous studies have shown that residential proximity to a roadway is associated with increased cardiovascular disease (CVD) risk. Yet the nature of this association remains unclear, and its impact on individual CVD risk factors has not been assessed. The objective of this study was to determine whether residential proximity to roadways influences systemic inflammation and the levels of circulating angiogenic cells. Approach and Results In a cross-sectional study, CVD risk factors, blood levels of C-reactive protein (CRP), and 15 antigenically-defined circulating angiogenic cell populations were measured in participants (n=316) with moderate to high CVD risk. Attributes of roadways surrounding residential locations were assessed using Geographic Information Systems. Associations between road proximity and cardiovascular indices were analyzed using Generalized Linear Models. Close proximity (<50m) to a major roadway was associated with lower income and higher rates of smoking, but not CRP levels. After adjustment for potential confounders, levels of circulating angiogenic cell in peripheral blood were significantly elevated in people living in close proximity to a major roadway (CD31+/AC133+, AC133+, CD34+/AC133+, and CD34+/45dim/AC133+ cells); and positively associated with road segment distance (CD31+/AC133+, AC133+, and CD34+/AC133+ cells), traffic intensity (CD31+/AC133+ and AC133+ cells), and distance-weighted traffic intensity (CD31+/34+/45+/AC133+ cells). Conclusions Living close to a major roadway is associated with elevated levels of circulating cells positive for the “early” stem marker, AC133+. This may reflect an increased need for vascular repair. Levels of these cells in peripheral blood may be a sensitive index of cardiovascular injury due to residential proximity to roadways. PMID:26293462

  14. Personality traits as potential susceptibility markers: differential susceptibility to support among parents.

    PubMed

    Slagt, Meike; Dubas, Judith Semon; Denissen, Jaap J A; Deković, Maja; van Aken, Marcel A G

    2015-04-01

    In this study, we examined whether parents are differentially susceptible to support from their spouse and adolescent child depending on their personality traits, and whether differences in susceptibility to support among parents, in turn, are linked to the quality of support parents give to their children. Participants in this three-wave longitudinal study were 288 two-parent Dutch families with an adolescent child. Fathers were on average 43.9 years old (SD = 3.7 years), mothers were 41.7 years old (SD = 3.3 years), and adolescents (50% girls) were 14.5 years old (SD = 0.8 years). We found that the association between support from children toward their parents and subsequent support from parents toward their children was more pronounced for parents high on Openness, for better and for worse. Extraversion, Agreeableness, Conscientiousness, and Emotional Stability did not emerge as markers of differences in susceptibility. Also, parents did not differ in their susceptibility to support from their spouse, nor were differences in susceptibility found a year later when using data from a third wave. We found very modest support for differential susceptibility, only for Openness, and depending on the source of perceived support and on the timing of measurement.

  15. Magnetization and magnetic susceptibility of DyH3

    NASA Technical Reports Server (NTRS)

    Flood, D. J.

    1975-01-01

    The magnetization and differential magnetic susceptibility of powdered DyH3 samples are measured at a temperature of 4.2 K in applied magnetic fields ranging up to 9 Teslas. The differential magnetic susceptibility is also investigated in the zero applied field. Magnetization is plotted as a function of field strength, and differential susceptibility is described as a function of both field strength and temperature. A saturation magnetic moment of 5.12 Bohr magnetons per ion is derived from the magnetization data, and the zero-field susceptibility measurements are found to indicate antiferromagnetic ordering below 3.45 K. The susceptibility at 4.2 K is shown to have an inverse-square dependence on field strength for values of not less than 0.3 Tesla.

  16. [Antimicrobial susceptibility cumulative reports].

    PubMed

    Canut-Blasco, Andrés; Calvo, Jorge; Rodríguez-Díaz, Juan Carlos; Martínez-Martínez, Luis

    2016-10-01

    Cumulative reports on antimicrobial susceptibility tests data are important for selecting empirical treatments, as an educational tool in programs on antimicrobial use, and for establishing breakpoints defining clinical categories. These reports should be based on data validated by clinical microbiologists using diagnostic samples (not surveillance samples). In order to avoid a bias derived from including several isolates obtained from the same patient, it is recommended that, for a defined period, only the first isolate is counted. A minimal number of isolates per species should be presented: a figure of >=30 isolates is statistically acceptable. The report is usually presented in a table format where, for each cell, information on clinically relevant microorganisms-antimicrobial agents is presented. Depending on particular needs, multiple tables showing data related to patients, samples, services or special pathogens can be prepared.

  17. Magnetic susceptibility of petroleum reservoir fluids

    NASA Astrophysics Data System (ADS)

    Ivakhnenko, Oleksandr P.; Potter, David K.

    A knowledge of the magnetic properties of petroleum reservoir fluids may provide new techniques for improved reservoir characterisation, petroleum exploration and production. However, magnetic information is currently scarce for the vast majority of reservoir fluids. For instance, there is little in the literature concerning basic magnetic susceptibility values of crude oils or formation waters. We have therefore measured the mass magnetic susceptibility ( χm) of several crude oils, refined oil fractions, and formation waters from local and world-wide sites. All the fluids measured were diamagnetic, however there were distinct differences in magnitude between the different fluid types. In particular, χm for the crude oils was more negative than for the formation waters of the same locality. The magnetic susceptibility of the oils appears to be related to their main physical and chemical properties. The results correlated with the density, residue content, API (American Petroleum Institute) gravity, viscosity, sulphur content and metal concentration of the fluids. Light fractions of crude oil were the most diamagnetic. The magnetic measurements potentially allow physical and chemical differences between the fluids to be rapidly characterised. The results suggest other possible applications, such as passive in situ magnetic susceptibility sensors for fluid monitoring (for example, the onset of water breakthrough, or the detection of migrating fines) in reservoirs, which would provide an environmentally friendly alternative to radioactive tracers. The mass magnetic susceptibilities of the fluids in relation to typical reservoir minerals may also play a role in fluid-rock interactions, such as studies of wettability. The χm of crude oil from the various world-wide oil provinces that were tested also showed some differences, possibly reflecting broad physical and chemical features of the geological history of each province.

  18. Comparative Genomics of Two ST 195 Carbapenem-Resistant Acinetobacter baumannii with Different Susceptibility to Polymyxin Revealed Underlying Resistance Mechanism

    PubMed Central

    Lean, Soo-Sum; Yeo, Chew Chieng; Suhaili, Zarizal; Thong, Kwai-Lin

    2016-01-01

    Acinetobacter baumannii is a Gram-negative nosocomial pathogen of importance due to its uncanny ability to acquire resistance to most antimicrobials. These include carbapenems, which are the drugs of choice for treating A. baumannii infections, and polymyxins, the drugs of last resort. Whole genome sequencing was performed on two clinical carbapenem-resistant A. baumannii AC29 and AC30 strains which had an indistinguishable ApaI pulsotype but different susceptibilities to polymyxin. Both genomes consisted of an approximately 3.8 Mbp circular chromosome each and several plasmids. AC29 (susceptible to polymyxin) and AC30 (resistant to polymyxin) belonged to the ST195 lineage and are phylogenetically clustered under the International Clone II (IC-II) group. An AbaR4-type resistance island (RI) interrupted the comM gene in the chromosomes of both strains and contained the blaOXA−23 carbapenemase gene and determinants for tetracycline and streptomycin resistance. AC29 harbored another copy of blaOXA−23 in a large (~74 kb) conjugative plasmid, pAC29b, but this gene was absent in a similar plasmid (pAC30c) found in AC30. A 7 kb Tn1548::armA RI which encodes determinants for aminoglycoside and macrolide resistance, is chromosomally-located in AC29 but found in a 16 kb plasmid in AC30, pAC30b. Analysis of known determinants for polymyxin resistance in AC30 showed mutations in the pmrA gene encoding the response regulator of the two-component pmrAB signal transduction system as well as in the lpxD, lpxC, and lpsB genes that encode enzymes involved in the biosynthesis of lipopolysaccharide (LPS). Experimental evidence indicated that impairment of LPS along with overexpression of pmrAB may have contributed to the development of polymyxin resistance in AC30. Cloning of a novel variant of the blaAmpC gene from AC29 and AC30, and its subsequent expression in E. coli also indicated its likely function as an extended-spectrum cephalosporinase. PMID:26779129

  19. Roebel assembled coated conductor cables (RACC): Ac-Losses and current carrying potential

    NASA Astrophysics Data System (ADS)

    Frank, A.; Heller, R.; Goldacker, W.; Kling, A.; Schmidt, C.

    2008-02-01

    Low ac-loss HTS cables for transport currents well above 1 kA are required for application in transformers and generators and are taken into consideration for future generations of fusion reactor coils. Coated conductors (CC) are suitable candidates for high field application at an operation temperature in the range 50-77 K. Ac-field applications require cables with low ac-losses and hence twisting of the individual strands. We solved this problem using the Roebel technique. Short lengths of Roebel bar cables were prepared from industrial DyBCO and YBCO-CC. Meander shaped tapes of 4 or 5 mm width with twist pitches of 123 or 127 mm were cut from the 10 or 12 mm wide CC tapes using a specially designed tool. Eleven or twelve of these strands were assembled to a cable. The electrical and mechanical connection of the tapes was achieved using a silver powder filled conductive epoxy resin. Ac-losses of a short sample in an external ac-field were measured as a function of frequency and field amplitude as well as the coupling current decay time constant. We discuss the results in terms of available theories and compare measured time constants in transverse field with measured coupling losses. Finally the potential of this cable type for ac-use is discussed with respect to ac-losses and current carrying capability.

  20. Magnetic susceptibility anisotropy outside the central nervous system.

    PubMed

    Dibb, Russell; Xie, Luke; Wei, Hongjiang; Liu, Chunlei

    2017-04-01

    Magnetic-susceptibility-based MRI has made important contributions to the characterization of tissue microstructure, chemical composition, and organ function. This has motivated a number of studies to explore the link between microstructure and susceptibility in organs and tissues throughout the body, including the kidney, heart, and connective tissue. These organs and tissues have anisotropic magnetic susceptibility properties and cellular organizations that are distinct from the lipid organization of myelin in the brain. For instance, anisotropy is traced to the epithelial lipid orientation in the kidney, the myofilament proteins in the heart, and the collagen fibrils in the knee cartilage. The magnetic susceptibility properties of these and other tissues are quantified using specific MRI tools: susceptibility tensor imaging (STI), quantitative susceptibility mapping (QSM), and individual QSM measurements with respect to tubular and filament directions determined from diffusion tensor imaging. These techniques provide complementary and supplementary information to that produced by traditional MRI methods. In the kidney, STI can track tubules in all layers including the cortex, outer medulla, and inner medulla. In the heart, STI detected myofibers throughout the myocardium. QSM in the knee revealed three unique layers in articular cartilage by exploiting the anisotropic susceptibility features of collagen. While QSM and STI are promising tools to study tissue susceptibility, certain technical challenges must be overcome in order to realize routine clinical use. This paper reviews essential experimental findings of susceptibility anisotropy in the body, the underlying mechanisms, and the associated MRI methodologies. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Dynamic susceptibility contrast MRI measures of relative cerebral blood volume as a prognostic marker for overall survival in recurrent glioblastoma: results from the ACRIN 6677/RTOG 0625 multicenter trial

    PubMed Central

    Schmainda, Kathleen M.; Zhang, Zheng; Prah, Melissa; Snyder, Bradley S.; Gilbert, Mark R.; Sorensen, A. Gregory; Barboriak, Daniel P.; Boxerman, Jerrold L.

    2015-01-01

    Background The study goal was to determine whether changes in relative cerebral blood volume (rCBV) derived from dynamic susceptibility contrast (DSC) MRI are predictive of overall survival (OS) in patients with recurrent glioblastoma multiforme (GBM) when measured 2, 8, and 16 weeks after treatment initiation. Methods Patients with recurrent GBM (37/123) enrolled in ACRIN 6677/RTOG 0625, a multicenter, randomized, phase II trial of bevacizumab with irinotecan or temozolomide, consented to DSC-MRI plus conventional MRI, 21 with DSC-MRI at baseline and at least 1 postbaseline scan. Contrast-enhancing regions of interest were determined semi-automatically using pre- and postcontrast T1-weighted images. Mean tumor rCBV normalized to white matter (nRCBV) and standardized rCBV (sRCBV) were determined for these regions of interest. The OS rates for patients with positive versus negative changes from baseline in nRCBV and sRCBV were compared using Wilcoxon rank-sum and Kaplan–Meier survival estimates with log-rank tests. Results Patients surviving at least 1 year (OS-1) had significantly larger decreases in nRCBV at week 2 (P = .0451) and sRCBV at week 16 (P = .014). Receiver operating characteristic analysis found the percent changes of nRCBV and sRCBV at week 2 and sRCBV at week 16, but not rCBV data at week 8, to be good prognostic markers for OS-1. Patients with positive change from baseline rCBV had significantly shorter OS than those with negative change at both week 2 and week 16 (P = .0015 and P = .0067 for nRCBV and P = .0251 and P = .0004 for sRCBV, respectively). Conclusions Early decreases in rCBV are predictive of improved survival in patients with recurrent GBM treated with bevacizumab. PMID:25646027

  2. Stress corrosion cracking susceptibility and some electrochemical characteristics of Inconel X-750 in lithiated water at 350°C

    NASA Astrophysics Data System (ADS)

    Sharkawy, S. W.; Xia, Z.; Szklarska-Smialowska, Z.

    1993-03-01

    The stress corrosion cracking (SCC) susceptibility of Inconel X-750 in the as-received (AR) and double aged (DA) conditions was investigated by the slow strain rate test (SSRT) in lithiated hydrogenated water at 350°C. The results showed that the DA condition was more susceptible to SCC than the AR one. Potentiodynamic polarization and AC impedance tests showed that the DA condition was characterized by higher dissolution rate and a lower tendency to passivation than the AR one.

  3. DESIGN OF AN AC-DIPOLE FOR USE IN RHIC.

    SciTech Connect

    PARKER,B.; BAI,M.; JAIN,A.; MCINTYRE,G.; METH,M.; PEGGS,S.; ROSER,T.; SANDERS,R.; TRBOJEVIC,D.

    1999-03-29

    We present two options for implementing a pair of AC-dipoles in RHIC for spin flipping, measuring linear optical functions and nonlinear diagnostics. AC-dipoles are magnets that can be adiabatically excited and de-excited with a continuous sine-wave in order to coherently move circulating beam out to large betatron amplitudes without incurring emittance blow up [1]. The AGS already uses a similar device for getting polarized proton beams through depolarizing resonances [2]. By placing the magnets in the IP4 common beam region, two AC-dipoles are sufficient to excite both horizontal and vertical motion in both RHIC rings. While we initially investigated an iron-dominated magnet design using available steel tape cores; we now favor a new air coil plus ferrite design featuring mechanical frequency tuning, in order to best match available resources to demanding frequency sweeping requirements. Both magnet designs are presented here along with model magnet test results. The challenge is to make AC-dipoles available for year 2000 RHIC running.

  4. Variation in susceptibility of Helicoverpa armigera (Hübner) and Helicoverpa punctigera (Wallengren) (Lepidoptera: Noctuidae) in Australia to two Bacillus thuringiensis toxins.

    PubMed

    Bird, Lisa J; Akhurst, Raymond J

    2007-02-01

    Intra-specific variation in susceptibility of Helicoverpa armigera (Hübner) and Helicoverpa punctigera (Wallengren) in Australia to the Cry1Ac and Cry2Ab delta-endotoxins from Bacillus thuringiensis (Berliner) (Bt) was determined to establish a baseline for monitoring changes that might occur with the use of Bt cotton. Strains of H. armigera and H. punctigera were established from populations collected primarily from commercial farms throughout the Australian cotton belts. Strains were evaluated for susceptibility using two bioassay methods (surface treatment and diet incorporation) by measuring the dose response for mortality (LC50) and growth inhibition (IC50). The variation in LC50 among H. armigera (n=17 strains) and H. punctigera (n=12 strains) in response to Cry1Ac was 4.6- and 3.2-fold, respectively. The variation in LC50 among H. armigera (n=19 strains) and H. punctigera (n=12 strains) to Cry2Ab was 6.6- and 3.5-fold, respectively. The range of Cry1Ac induced growth inhibition from the 3rd to 4th instar in H. armigera (n=15 strains) was 3.6-fold and in H. punctigera (n=13 strains) was 2.6-fold, while the range of Cry2Ab induced growth inhibition from neonate to 3rd instar in H. armigera (n=13 strains) was 4.3-fold and in H. punctigera (n=12 strains) was 6.1-fold. Variation in susceptibility was also evaluated for two age classes (neonates and 3rd instars) in laboratory strains of H. armigera and H. punctigera. Neonates of H. punctigera had the same or higher sensitivity to Bt than 3rd instars. Neonates of H. armigera were more sensitive to Cry2Ab than 3rd instars, while being less sensitive to Cry1Ac than 3rd instars. Differences in the two methods of bioassay used affected relative sensitivity of species to Bt toxins, highlighting the need to standardize bioassay protocols.

  5. Hypnotic Susceptibility and Frequency Reports to Illusory Stimuli

    ERIC Educational Resources Information Center

    Wallace, Benjamin; And Others

    1976-01-01

    Explores the possibility that measurable individual differences in hypnotic susceptibility or the ability to attend selectively to informational cues may account for a portion of the variability found in several types of geometrical visual illusions. (Author/RK)

  6. Using triaxial magnetic fields to create high susceptibility particle composites.

    PubMed

    Martin, James E; Venturini, Eugene; Gulley, Gerald L; Williamson, Jonathan

    2004-02-01

    We report on the use of triaxial magnetic fields to create a variety of isotropic and anisotropic magnetic particle/polymer composites with significantly enhanced magnetic susceptibilities. A triaxial field is a superposition of three orthogonal ac magnetic fields, each generated by a Helmholtz coil in series resonance with a tunable capacitor bank. Field frequencies are in the range of 150-400 Hz. Because both the field amplitudes and frequencies can be varied, a rich variety of structures can be created. Perhaps the most unusual effects occur when either two or three of the field components are heterodyned to give beat frequencies on the order of 1 Hz. This leads to a striking particle dynamics that evolves into surprising structures during resin gelation. These structures are found to have perhaps the highest susceptibility that a particle composite can have. The susceptibility anisotropy of these composites can be controlled over a wide range by judicious adjustment of the relative field amplitudes. These experimental data are supported by large-scale Brownian dynamics simulations of the complex many-body interactions that occur in triaxial magnetic fields. These simulations show that athermal three-dimensional field heterodyning leads to structures with a susceptibility that is as high as that achieved with thermal annealing. Thus with coherent particle motions we can achieve magnetostatic energies that are quite close to the ground state.

  7. Profiles of Epigenetic Histone Post-translational Modifications at Type 1 Diabetes Susceptible Genes*

    PubMed Central

    Miao, Feng; Chen, Zhuo; Zhang, Lingxiao; Liu, Zheng; Wu, Xiwei; Yuan, Yate-Ching; Natarajan, Rama

    2012-01-01

    Both genetic and environmental factors are implicated in type 1 diabetes (T1D). Because environmental factors can trigger epigenetic changes, we hypothesized that variations in histone post-translational modifications (PTMs) at the promoter/enhancer regions of T1D susceptible genes may be associated with T1D. We therefore evaluated histone PTM variations at known T1D susceptible genes in blood cells from T1D patients versus healthy nondiabetic controls, and explored their connections to T1D. We used the chromatin immunoprecipitation-linked to microarray approach to profile key histone PTMs, including H3-lysine 4 trimethylation (H3K4me3), H3K27me3, H3K9me3, H3K9 acetylation (H3K9Ac), and H4K16Ac at genes within the T1D susceptible loci in lymphocytes, and H3K4me3, H3K9me2, H3K9Ac, and H4K16Ac at the insulin-dependent diabetes mellitus 1 region in monocytes of T1D patients and healthy controls separately. We screened for potential variations in histone PTMs using computational methods to compare datasets from T1D and controls. Interestingly, we observed marked variations in H3K9Ac levels at the upstream regions of HLA-DRB1 and HLA-DQB1 within the insulin-dependent diabetes mellitus 1 locus in T1D monocytes relative to controls. Additional experiments with THP-1 monocytes demonstrated increased expression of HLA-DRB1 and HLA-DQB1 in response to interferon-γ and TNF-α treatment that were accompanied by changes in H3K9Ac at the same promoter regions as that seen in the patient monocytes. These results suggest that the H3K9Ac status of HLA-DRB1 and HLA-DQB1, two genes highly associated with T1D, may be relevant to their regulation and transcriptional response toward external stimuli. Thus, the promoter/enhancer architecture and chromatin status of key susceptible loci could be important determinants in their functional association to T1D susceptibility. PMID:22431725

  8. Separation of magnetic susceptibility components from magnetization curves

    NASA Astrophysics Data System (ADS)

    Kosareva, L.; Nourgaliev, D.; Kuzina, D.; Spassov, S.; Fattakhov, A.

    2014-12-01

    Modern lake sediments are a unique source of information for climate changes, regionally and globally, because all environmental variations are recorded by these sediments with high resolution. The magnetic properties of Chernyshov Bay (Aral Sea) sediments we investigated from core number 4 (N45o57'04.2''; E59o17'14.3'') are taken at far water depth of 9.5 m. The length of the core is 4.16 m. Samples for measurements were taken to plastic sample boxes with internal dimensions 2x2x2 cm. Remanent magnetization curves were measured by coercivity spectrometer for the separate determination of the different contributions to the total bulk magnetic susceptibility. There was measured also magnetic susceptibility using MS2 susceptibility meter. Those operations were done for data comparison between 2 susceptibilities obtained from different equipment. Our goal is to decipher the magnetic susceptibility signal in lake sediments by decomposing the bulk susceptibility signal of a lake sediment sequence into ferromagnetic (χf), dia-/paramagnetic (χp) and superparamagnetic (χsp) components using data from remanent and indused magnetization curves Each of these component has a different origin: paramagnetic minerals are usually attributed to terrigenous sediment input, ferromagnetics are of biogenic origin, and superparamagnetic minerals may be of either biogenic or terrigenous origin. Comparison between susceptibility measurements of MS2-Bartington susceptometer and of the coercivity spectrometer has shown good correlation. The susceptibility values measured in two different equipment are fairly close and indicate thus the reliability the proposed method. In research also has shown water level changes in Aral Sea based on magnetic susceptibility. The work is performed according to the Russian Government Program of Competitive Growth of Kazan Federal University also by RFBR research projects No. 14-05-31376 - а, 14-05-00785- а.

  9. An Antimicrobial Susceptibility Management System

    PubMed Central

    Farmer, James J.; O'Donnell, Edward D.

    1981-01-01

    A computerized system is described which is used to store, manipulate and retrieve antimicrobial susceptibility data in the clinical microbiology lab. Features include facilitated input of susceptibility data, rapid generation of reports, realtime access to data, and enhanced retrieval of information for Infection Control.

  10. Electric-Field Instrument With Ac-Biased Corona Point

    NASA Technical Reports Server (NTRS)

    Markson, R.; Anderson, B.; Govaert, J.

    1993-01-01

    Measurements indicative of incipient lightning yield additional information. New instrument gives reliable readings. High-voltage ac bias applied to needle point through high-resistance capacitance network provides corona discharge at all times, enabling more-slowly-varying component of electrostatic potential of needle to come to equilibrium with surrounding air. High resistance of high-voltage coupling makes instrument insensitive to wind. Improved corona-point instrument expected to yield additional information assisting in safety-oriented forecasting of lighting.

  11. Susceptibility of pathogenic and nonpathogenic Naegleria ssp

    SciTech Connect

    Whiteman, L.Y.

    1988-01-01

    The susceptibility of four species of Naegleria amoebae to complement-mediated lysis was determined. The amoebicidal activity of normal human serum (NHS) and normal guinea pig serum (NGPS) for Naegleria amoebae was measured by an in vitro cytotoxicity assay. Release of radioactivity from amoebae labeled with {sup 3}H-uridine and visual observation with a compound microscope were used as indices of lysis. Susceptibility or resistance to complement-mediated lysis in vitro correlated with the in vivo pathogenic potential. Nonpathogenic Naegleria amoebae were lysed at a faster rate and at higher cell concentrations than were pathogenic amoebae. Electrophoretic analysis of NHS incubated with pathogenic or nonpathogenic Naegleria spp. demonstrated that amoebae activate the complement cascade resulting in the production of C3 and C5 complement cleavage products. Treatment with papain or trypsin for 1 h, but not with sialidase, increase the susceptibility of highly pathogenic, mouse-passaged N. fowleri to lysis. Treatment with actinomycin D, cycloheximide or various protease inhibitors for 4 h did not increase susceptibility to lysis. Neither a repair process involving de novo protein synthesis nor a complement-inactivating protease appear to account for the increase resistance of N. fowleri amoebae to complement-mediated lysis. A binding study with {sup 125}I radiolabeled C9 indicated that the terminal complement component does not remain stably bound to the membrane of pathogenic amoebae.

  12. Genetic Susceptibility to Lymphoma

    PubMed Central

    Skibola, Christine F.; Curry, John D.; Nieters, Alexandra

    2010-01-01

    BACKGROUND Genetic susceptibility studies of lymphoma may serve to identify at risk populations and to elucidate important disease mechanisms. METHODS This review considered all studies published through October 2006 on the contribution of genetic polymorphisms in the risk of lymphoma. RESULTS Numerous studies implicate the role of genetic variants that promote B-cell survival and growth with increased risk of lymphoma. Several reports including a large pooled study by InterLymph, an international consortium of non-Hodgkin lymphoma (NHL) case-control studies, found positive associations between variant alleles in TNF -308G>A and IL10 -3575T>A genes and risk of diffuse large B-cell lymphoma. Four studies reported positive associations between a GSTT1 deletion and risk of Hodgkin and non-Hodgkin lymphoma. Genetic studies of folate-metabolizing genes implicate folate in NHL risk, but further studies that include folate and alcohol assessments are needed. Links between NHL and genes involved in energy regulation and hormone production and metabolism may provide insights into novel mechanisms implicating neuro- and endocrine-immune cross-talk with lymphomagenesis, but will need replication in larger populations. CONCLUSIONS Numerous studies suggest that common genetic variants with low penetrance influence lymphoma risk, though replication studies will be needed to eliminate false positive associations. PMID:17606447

  13. Topological susceptibility with the improved Asqtad action

    SciTech Connect

    C. Bernard et al.

    2004-01-06

    As a test of the chiral properties of the improved Asqtad (staggered fermion) action, we have been measuring the topological susceptibility as a function of quark masses for 2 + 1 dynamical flavors. We report preliminary results, which show reasonable agreement with leading order chiral perturbation theory for lattice spacing less than 0.1 fm. The total topological charge, however, shows strong persistence over Monte Carlo time.

  14. Test plan for performance testing of the Eaton AC-3 electric vehicle

    SciTech Connect

    Crumley, R.L.; Heiselmann, H.W.

    1985-04-01

    An alternating current (ac) propulsion system for an electric vehicle has been developed and tested by the Eaton Corporation. The test bed vehicle is a modified 1981 Mercury Lynx. The test plan has been prepared specifically for the third modification to this test bed and identified as the Eaton AC-3. The scope of the EG and G testing at INEL to be done on the Eaton AC-3 will include coastdown and dynamometer tests but will not include environmental, on-road, or track testing. Coastdown testing will be performed in accordance with SAE J-1263 (SAE Recommended Practice for Road Load Measurement and Dynamometer Simulation Using Coastdown Techniques).

  15. Application of the A.C. Admittance Technique to Double Layer Studies on Polycrystalline Gold Electrodes

    DTIC Science & Technology

    1992-02-24

    Chemistry University of California Davis, CA 95616 U.S.A. tOn leave from the Instituto de Fisica e Quimica de Sao Carlos, USP, Sao Carlos, SP 13560...input of the PAR 174A through an attentuator. The attentuator was introduced in order to avoid signal noise from the a.c. signal generator which is...surface begins. A.C. Admittance Measurements A.C. admittance data were gathered as a function of d.c. potential and frequency. In general , the gold

  16. System and method for monitoring and controlling stator winding temperature in a de-energized AC motor

    DOEpatents

    Lu, Bin [Kenosha, WI; Luebke, Charles John [Sussex, WI; Habetler, Thomas G [Snellville, GA; Zhang, Pinjia [Atlanta, GA; Becker, Scott K [Oak Creek, WI

    2011-12-27

    A system and method for measuring and controlling stator winding temperature in an AC motor while idling is disclosed. The system includes a circuit having an input connectable to an AC source and an output connectable to an input terminal of a multi-phase AC motor. The circuit further includes a plurality of switching devices to control current flow and terminal voltages in the multi-phase AC motor and a controller connected to the circuit. The controller is configured to activate the plurality of switching devices to create a DC signal in an output of the motor control device corresponding to an input to the multi-phase AC motor, determine or estimate a stator winding resistance of the multi-phase AC motor based on the DC signal, and estimate a stator temperature from the stator winding resistance. Temperature can then be controlled and regulated by DC injection into the stator windings.

  17. Pyrolytic Graphite Foam: A Passive Magnetic Susceptibility Matching Material

    PubMed Central

    Lee, Gary C.; Goodwill, Patrick W.; Phuong, Kevin; Inglis, Ben A.; Scott, Greig C.; Hargreaves, Brian A.; Li, Lizabeth; Chen, Alex C.; Shah, Rachana N.; Conolly, Steven M.

    2012-01-01

    Purpose To evaluate a novel soft, lightweight cushion that can match the magnetic susceptibility of human tissue. The magnetic susceptibility difference between air and tissue produces field inhomogeneities in the B0 field, which leads to susceptibility artifacts in MR studies. Materials and Methods Pyrolytic graphite (PG) microparticles are uniformly embedded into a foam cushion to reduce or eliminate field inhomogeneities at accessible air and tissue interfaces. 3T MR images and field maps of an air/water/PG foam phantom were acquired. Q measurements on a 4T tuned head coil and pulse sequence heating tests at 3T were also performed. Results The PG foam improved susceptibility matching, reduced the field perturbations in phantoms, does not heat, and is non-conductive. Conclusion The susceptibility matched PG foam is lightweight, safe for patient use, adds no noise or MRI artifacts, is compatible with RF coil arrays, and improves B0 homogeneity, which enables more robust MR studies. PMID:20815067

  18. Total AC loss characteristics of untwisted and twisted Bi-2223 multifilamentary tapes and interaction between self and external magnetic fields

    NASA Astrophysics Data System (ADS)

    Jiang, Zhenan; Amemiya, Naoyuki; Ayai, Naoki; Hayashi, Kazuhiko

    2004-11-01

    The authors have electrically measured the total AC losses of untwisted and twisted Bi-2223 multifilamentary tapes in AC parallel and perpendicular transverse magnetic fields. The magnetization and transport losses in the untwisted and twisted Bi-2223 multifilamentary tapes carrying an AC transport current in AC parallel and perpendicular transverse magnetic fields were measured independently to obtain the total AC loss. The total AC losses of both the untwisted and twisted Bi-2223 multifilamentary tapes in a parallel transverse magnetic field are approximately equal to the sum of the transport loss without the external magnetic field and the magnetization loss without the transport current. In particular, the total AC loss of the twisted tape in a parallel transverse magnetic field is in good agreement with this sum. On the other hand, the total AC losses of both the untwisted and twisted Bi-2223 multifilamentary tapes in a perpendicular transverse magnetic field are larger than the sum of the transport loss without any external magnetic field and the magnetization loss without transport current. The total AC loss of the twisted tape in a parallel transverse magnetic field can be predicted by the sum of the magnetization loss using the slab model for an equivalent filament thickness and the transport loss given by Norris for a superconductor with an elliptical cross section.

  19. Increased Long-Flight Activity Triggered in Beet Armyworm by Larval Feeding on Diet Containing Cry1Ac Protoxin

    PubMed Central

    Jiang, Xing Fu; Chen, Jian; Zhang, Lei; Sappington, Thomas W.; Luo, Li Zhi

    2013-01-01

    Evaluating ecological safety and conducting pest risk analysis for transgenic crops are vitally important before their commercial planting. The beet armyworm, Spodoptera exigua, a long-distance migratory insect pest, is not a direct target of transgenic Cry1Ac-expressing cotton in China, but nevertheless it has recently become an important pest. Migrants leaving their natal field arrive in other appropriate habitat far away in a short time, often followed by larval outbreaks. S. exigua has low susceptibility to Cry1Ac. However, our results from laboratory experiments identified (i) sublethal effects of Cry1Ac protoxin on larval development rate, larval and pupal weight, and adult lifetime fecundity, and (ii) increased long-flight behavior triggered by Cry1Ac which may contribute to larval outbreaks elsewhere. No significant differences in larval mortality, pupation rate, adult emergence rate, longevity, pre-oviposition period, or oviposition period were observed between controls and larvae fed on artificial diet incorporating a low concentration of Cry1Ac protoxin. The negative sublethal effects on some developmental and reproductive traits and lack of effect on others suggest they do not contribute to the observed severity of S. exigua outbreaks after feeding on Cry1Ac cotton. Interestingly, the percentage of long fliers increased significantly when larvae were reared on diet containing either of two low-dose treatments of Cry1Ac, suggesting a possible increased propensity to disperse long distances triggered by Cry1Ac. We hypothesize that negative effects on development and reproduction caused by Cry1Ac in the diet are offset by increased flight propensity triggered by the poor food conditions, thereby improving the chances of escaping adverse local conditions before oviposition. Increased long-flight propensity in turn may amplify the area damaged by outbreak populations. This phenomenon might be common in other migratory insect pests receiving sublethal doses

  20. Diagnosis of susceptibility to malignant hyperthermia with flanking DNA markers.

    PubMed Central

    Healy, S J; Heffron, J J; Lehane, M; Bradley, D G; Johnson, K; McCarthy, T V

    1991-01-01

    OBJECTIVE--To define the region on human chromosome 19 carrying the gene for malignant hyperthermia susceptibility and to evaluate the use of flanking DNA markers in diagnosing susceptibility. DESIGN--Prospective molecular genetic linkage studies in a large malignant hyperthermia pedigree. SETTING--Irish malignant hyperthermia testing centre. SUBJECTS--A large Irish malignant hyperthermia pedigree. MAIN OUTCOME MEASURES--Routine diagnosis of susceptibility to malignant hyperthermia with in vitro contracture test on muscle biopsy specimens and genetic linkage between susceptibility and polymorphic DNA markers in a malignant hyperthermia family. RESULTS--Genetic typing of polymorphic DNA markers in a large Irish malignant hyperthermia pedigree generated a lod score of greater than 3 for the marker D19S9 and showed that the gene for susceptibility is flanked by the markers D19S9 and D19S16. These tightly linked flanking markers allowed non-invasive presymptomatic diagnosis of susceptibility in five untested subjects in the large pedigree with an accuracy of greater than 99.7%. CONCLUSIONS--DNA markers flanking the gene for susceptibility to malignant hyperthermia can be used with high accuracy to diagnose susceptibility in subjects in large known malignant hyperthermia pedigrees and may replace the previous in vitro contracture test for diagnosing this inherited disorder in large families with malignant hyperthermia. PMID:1684123

  1. Three phase AC motor controller

    DOEpatents

    Vuckovich, Michael; Wright, Maynard K.; Burkett, John P.

    1984-03-20

    A motor controller for a three phase AC motor (10) which is adapted to operate bidirectionally from signals received either from a computer (30) or a manual control (32). The controller is comprised of digital logic circuit means which implement a forward and reverse command signal channel (27, 29) for the application of power through the forward and reverse power switching relays (16, 18, 20, 22). The digital logic elements are cross coupled to prevent activation of both channels simultaneously and each includes a plugging circuit (65, 67) for stopping the motor upon the removal of control signal applied to one of the two channels (27, 29) for a direction of rotation desired. Each plugging circuit (65, 67) includes a one-shot pulse signal generator (88, 102) which outputs a single pulse signal of predetermined pulsewidth which is adapted to inhibit further operation of the application of power in the channel which is being activated and to apply a reversal command signal to the other channel which provides a reversed phase application of power to the motor for a period defined by the pulse-width output of the one-shot signal generator to plug the motor (10) which will then be inoperative until another rotational command signal is applied to either of the two channels.

  2. Genetic susceptibility to occupational exposures

    PubMed Central

    Christiani, D C; Mehta, A J; Yu, C-L

    2013-01-01

    Because of their high prevalence in the general population, genetic variants that determine susceptibility to environmental exposures may contribute greatly to the development of occupational diseases in the setting of specific exposures occurring in the workplace. Studies investigating genetic susceptibilities in the workplace may: (1) provide mechanistic insight into the aetiology of disease, in particular the determination of environmentally responsive genes; (2) identify susceptible subpopulations with respect to exposure; and (3) provide valuable input in setting occupational exposure limits by taking genetic susceptibility into account. Polymorphisms in the NAT2 and the HLA-DPB1Glu69 genes provide classic examples of how genetic susceptibility markers have a clear role in identifying disease risk in bladder cancer and chronic beryllium disease, respectively. For diseases with more complex and multifactorial aetiology such as occupational asthma and chronic airways disease, susceptibility studies for selected genetic polymorphisms provide additional insight into the biological mechanisms of disease. Even when polymorphisms for genetic susceptibility have a clear role in identifying disease risk, the value of wide scale genetic screening in occupational settings remains limited due to primarily ethical and social concerns. Thus, large scale genetic screening in the workplace is not currently recommended. PMID:18487431

  3. Memory effect in ac plasma displays

    NASA Astrophysics Data System (ADS)

    Szlenk, K.; Obuchowicz, E.

    1993-10-01

    The bistable or `memory' mode of operation of an ac plasma display panel is presented. The difference between dc and ac plasma panel operation from the point of view of memory function is discussed. The graphic ac plasma display with thin film Cr-Cu-Cr electrodes was developed in OBREP and its basic parameters are described. It consists of 36 X 59 picture elements, its outer dimensions are: 76 X 52 mm2 and the screen size is: 49 X 30 mm2. The different dielectric glass materials were applied as dielectric layers and the influence of the properties of these materials on display parameters and memory function was investigated.

  4. Common, but complex, mode of resistance of Plutella xylostella to Bacillus thuringiensis toxins Cry1Ab and Cry1Ac.

    PubMed

    Sayyed, Ali H; Gatsi, Roxani; Ibiza-Palacios, M Sales; Escriche, Baltasar; Wright, Denis J; Crickmore, Neil

    2005-11-01

    A field collected population of Plutella xylostella (SERD4) was selected in the laboratory with Bacillus thuringiensis endotoxins Cry1Ac (Cry1Ac-SEL) and Cry1Ab (Cry1Ab-SEL). Both subpopulations showed similar phenotypes: high resistance to the Cry1A toxins and little cross-resistance to Cry1Ca or Cry1D. A previous analysis of the Cry1Ac-SEL showed incompletely dominant resistance to Cry1Ac with more than one factor, at least one of which was sex influenced. In the present study reciprocal mass crosses between Cry1Ab-SEL and a laboratory susceptible population (ROTH) provided evidence that Cry1Ab resistance was also inherited as incompletely dominant trait with more than one factor, and at least one of the factors was sex influenced. Analysis of single pair mating indicated that Cry1Ab-SEL was still heterogeneous for Cry1Ab resistance genes, showing genes with different degrees of dominance. Binding studies showed a large reduction of specific binding of Cry1Ab and Cry1Ac to midgut membrane vesicles of the Cry1Ab-SEL subpopulation. Cry1Ab-SEL was found to be more susceptible to trypsin-activated Cry1Ab toxin than protoxin, although no defect in toxin activation was found. Present and previous results indicate a common basis of resistance to both Cry1Ab and Cry1Ac in selected subpopulations and suggest that a similar set of resistance genes are responsible for resistance to Cry1Ab and Cry1Ac and are selected whichever toxin was used. The possibility of an incompletely dominant trait of resistant to these toxins should be taken into account when considering refuge resistance management strategies.

  5. Regular structures in 5CB liquid crystals under the joint action of ac and dc voltages

    NASA Astrophysics Data System (ADS)

    Aguirre, Luis E.; Anoardo, Esteban; Éber, Nándor; Buka, Ágnes

    2012-04-01

    A nematic liquid crystal with high, positive dielectric anisotropy (5CB) has been studied under the influence of the combined action of a dc and an ac electric field. Broad frequency, voltage, and cell thickness ranges were considered. Pattern morphologies were identified; the thresholds and critical wave numbers were measured and analyzed as a function of frequency, dc-to-ac voltage ratio, and thickness. The current-voltage characteristics were simultaneously detected.

  6. Resistance to Bacillus thuringiensis Mediated by an ABC Transporter Mutation Increases Susceptibility to Toxins from Other Bacteria in an Invasive Insect.

    PubMed

    Xiao, Yutao; Liu, Kaiyu; Zhang, Dandan; Gong, Lingling; He, Fei; Soberón, Mario; Bravo, Alejandra; Tabashnik, Bruce E; Wu, Kongming

    2016-02-01

    Evolution of pest resistance reduces the efficacy of insecticidal proteins from the gram-positive bacterium Bacillus thuringiensis (Bt) used widely in sprays and transgenic crops. Recent efforts to delay pest adaptation to Bt crops focus primarily on combinations of two or more Bt toxins that kill the same pest, but this approach is often compromised because resistance to one Bt toxin causes cross-resistance to others. Thus, integration of Bt toxins with alternative controls that do not exhibit such cross-resistance is urgently needed. The ideal scenario of negative cross-resistance, where selection for resistance to a Bt toxin increases susceptibility to alternative controls, has been elusive. Here we discovered that selection of the global crop pest, Helicoverpa armigera, for >1000-fold resistance to Bt toxin Cry1Ac increased susceptibility to abamectin and spineotram, insecticides derived from the soil bacteria Streptomyces avermitilis and Saccharopolyspora spinosa, respectively. Resistance to Cry1Ac did not affect susceptibility to the cyclodiene, organophospate, or pyrethroid insecticides tested. Whereas previous work demonstrated that the resistance to Cry1Ac in the strain analyzed here is conferred by a mutation disrupting an ATP-binding cassette protein named ABCC2, the new results show that increased susceptibility to abamectin is genetically linked with the same mutation. Moreover, RNAi silencing of HaABCC2 not only decreased susceptibility to Cry1Ac, it also increased susceptibility to abamectin. The mutation disrupting ABCC2 reduced removal of abamectin in live larvae and in transfected Hi5 cells. The results imply that negative cross-resistance occurs because the wild type ABCC2 protein plays a key role in conferring susceptibility to Cry1Ac and in decreasing susceptibility to abamectin. The negative cross-resistance between a Bt toxin and other bacterial insecticides reported here may facilitate more sustainable pest control.

  7. Resistance to Bacillus thuringiensis Mediated by an ABC Transporter Mutation Increases Susceptibility to Toxins from Other Bacteria in an Invasive Insect

    PubMed Central

    Zhang, Dandan; Gong, Lingling; He, Fei; Soberón, Mario; Bravo, Alejandra; Tabashnik, Bruce E.; Wu, Kongming

    2016-01-01

    Evolution of pest resistance reduces the efficacy of insecticidal proteins from the gram-positive bacterium Bacillus thuringiensis (Bt) used widely in sprays and transgenic crops. Recent efforts to delay pest adaptation to Bt crops focus primarily on combinations of two or more Bt toxins that kill the same pest, but this approach is often compromised because resistance to one Bt toxin causes cross-resistance to others. Thus, integration of Bt toxins with alternative controls that do not exhibit such cross-resistance is urgently needed. The ideal scenario of negative cross-resistance, where selection for resistance to a Bt toxin increases susceptibility to alternative controls, has been elusive. Here we discovered that selection of the global crop pest, Helicoverpa armigera, for >1000-fold resistance to Bt toxin Cry1Ac increased susceptibility to abamectin and spineotram, insecticides derived from the soil bacteria Streptomyces avermitilis and Saccharopolyspora spinosa, respectively. Resistance to Cry1Ac did not affect susceptibility to the cyclodiene, organophospate, or pyrethroid insecticides tested. Whereas previous work demonstrated that the resistance to Cry1Ac in the strain analyzed here is conferred by a mutation disrupting an ATP-binding cassette protein named ABCC2, the new results show that increased susceptibility to abamectin is genetically linked with the same mutation. Moreover, RNAi silencing of HaABCC2 not only decreased susceptibility to Cry1Ac, it also increased susceptibility to abamectin. The mutation disrupting ABCC2 reduced removal of abamectin in live larvae and in transfected Hi5 cells. The results imply that negative cross-resistance occurs because the wild type ABCC2 protein plays a key role in conferring susceptibility to Cry1Ac and in decreasing susceptibility to abamectin. The negative cross-resistance between a Bt toxin and other bacterial insecticides reported here may facilitate more sustainable pest control. PMID:26872031

  8. Decrease of magnetic AC loss in twisted-filament Bi-2223 tapes

    NASA Astrophysics Data System (ADS)

    Oomen, M. P.; Rieger, J.; Leghissa, M.; Fischer, B.; Arndt, Th.

    1998-12-01

    In AC power-engineering applications, a large part of the AC loss in the superconductor is due to magnetization by the external field. This magnetic AC loss has been well described for the low- Tc conductors. In Bi-2223 tapes the picture is different due to strong anisotropy, granularity and flux creep. Magnetic AC loss in various twisted and non-twisted Bi-2223 tapes has been measured at power frequencies by a pickup method. The results are compared to theoretical models of magnetization loss. When the field is parallel to the tape plane, the filaments in twisted tapes can be decoupled and the AC loss is decreased even when the matrix is pure silver. The extra effect of higher-resistance matrix materials is studied. In perpendicular field it is more difficult to decouple the filaments, due to the particular tape geometry. Contrary to a wire, there are essential differences between the AC loss mechanisms in a long twisted tape and those in a short piece of non-twisted tape. Finally, the dynamic resistance caused by the AC magnetic field is examined.

  9. Faith and oscillations recovered: On analyzing EEG/MEG signals during tACS.

    PubMed

    Neuling, Toralf; Ruhnau, Philipp; Weisz, Nathan; Herrmann, Christoph S; Demarchi, Gianpaolo

    2017-02-15

    Despite recent success in analyzing brain oscillations recorded during transcranial alternating current stimulation (tACS), the field still requires further research to establish standards in artifact removal methods. This includes taking a step back from the removal of the tACS artifact and thoroughly characterizing the to-be-removed artifact. A recent study by Noury et al. (2016) contributed importantly to this endeavour by showing the existence of nonlinear artefacts in the tACS signal as seen by MEG and EEG. Unfortunately however this paper conveys the message that current artifact removal attempts have failed altogether and that-based on these available tools-brain oscillations recorded during tACS cannot be analyzed using MEG and EEG. Here we want to balance this overly pessimistic conclusion: In-depth reanalyses of our own data and phantom-head measurements indicate that nonlinearities can occur, but only when technical limits of the stimulator are reached. As such they are part of the "real" stimulation and not a specific MEG analysis problem. Future tACS studies should consider these technical limits to avoid any nonlinear modulations of the tACS artifact. We conclude that even with current approaches, brain oscillations recorded during tACS can be meaningfully studied in many practical cases.

  10. Phase-sensitive detection of both inductive and non-inductive ac voltages in ferromagnetic resonance

    NASA Astrophysics Data System (ADS)

    Weiler, Mathias; Shaw, Justin M.; Nembach, Hans T.; Schoen, Martin A.; Boone, Carl T.; Silva, Thomas J.

    2014-03-01

    Spin pumping causes significant damping in ultrathin ferromagnetic/normal metal (NM) multilayers via spin-current generation of both dc and ac character in the NM system. While the nonlinear dc component has been investigated in detail by utilization of the inverse spin Hall effect (iSHE) in NMs, much less is known about the linear ac component that is presumably much larger in the small-excitation limit. We measured generated ac voltages in a wide variety of Permalloy/NM multilayers via vector-network-analyzer ferromagnetic resonance. We employ a custom, impedance-matched, broadband microwave coupler that features a ferromagnetic thin film reference resonator to accurately compare ac voltage amplitudes and phases between varieties of multilayers. By use of the fact that inductive and ac iSHE signals are phase-shifted by π/2, we find that inductive signals are major contributors in all investigated samples. It is only by comparison of the phase and amplitude of the recorded ac voltages between multiple samples that we can extract the non-inductive contributions due to spin-currents. Voltages due to the ac iSHE in Permalloy(10nm)/platinum(5nm) bilayers are weaker than inductive signals, in agreement with calculations based upon recent theoretical predictions. M.W. acknowledges financial support by the German Academic Exchange service (DAAD).

  11. Transport signatures in topological systems coupled to ac fields

    NASA Astrophysics Data System (ADS)

    Ruocco, Leonard; Gómez-León, Álvaro

    2017-02-01

    We study the transport properties of a topological system coupled to an ac electric field by means of Floquet-Keldysh formalism. We consider a semi-infinite chain of dimers coupled to a semi-infinite metallic lead and obtain the density of states and current when the system is out of equilibrium. Our formalism is nonperturbative and allows us to explore, in the thermodynamic limit, a wide range of regimes for the ac field, arbitrary values of the coupling strength to the metallic contact and corrections to the wide-band limit (WBL). We find that hybridization with the contact can change the dimerization phase, and that the current dependence on the field amplitude can be used to discriminate between them. We also show the appearance of side bands and nonequilibrium zero-energy modes, characteristic of the Floquet systems. Our results directly apply to the stability of nonequilibrium topological phases, when transport measurements are used for their detection.

  12. Evaluation of a rapid Bauer-Kirby antibiotic susceptibility determination.

    PubMed

    Liberman, D F; Robertson, R G

    1975-03-01

    To reduce the incubation time requirement in the Bauer-Kirby antibiotic susceptibility test, comparisons were made of the test results at 18 to 20 h (standard) and 7 to 8 h (rapid) utilizing 100 recent clinical isolates. The zone diameters for 664 disks were monitored by using the standard classification: resistant, intermediate, or susceptible. The susceptibility determination was unchanged in 558 out of 664 instances (84.0%). An analysis of the remaining 106 sets revealed that an initial interpretation of intermediate in zone size, subsequently determined resistant or susceptible, accounted for 49 of the observed differences. The reverse changes, initial resistant or susceptible subsequently classified as intermediate, accounted for 20 of the changes. In five instances the interpretation changed from susceptible to resistant; in two cases the interpretation changed from resistant to susceptible. The remaining 30 determinations were classified as indeterminant due to (i) insufficient growth at the early (7 to 8 h) determination, and to (ii) zones which were so large that they could not be measured accurately. The data indicate that zone sizes when measured to the nearest 0.1 mm can be interpreted with reasonable accuracy and the results can be available 10 to 14 h sooner.

  13. Ocular vestibular evoked myogenic potentials to air conduction (AC oVEMP): useful in clinical practice?

    PubMed

    Walther, L E; Rogowski, M; Hörmann, K; Schaaf, H; Löhler, J

    2011-01-01

    Cervical vestibular-evoked myogenic potential (cVEMP) and ocular VEMP (oVEMP) stimuli can be used to measure otolith function using air (AC) and bone conducted (BC) stimuli. Cervical VEMPs reflect saccular function and can be recorded using air conduction (AC), whereas oVEMPs reflect probably predominantly utricular function. Air- and bone-conducted vibration can be used, because AC oVEMP methodology seems to be fast and simple in clinical practice to measure otolith function. In this study we discuss the advantages and problems of AC oVEMP stimulation. AC oVEMP can be easily and quickly obtained within a few seconds. N10 (first negative peak) and p15 (first positive peak) latencies may be used as parameters for clinical interpretation but amplitude fluctuations are relatively large. For daily clinical use of VEMP visualization in a normogram seems feasible. Especially the AC oVEMP methodology (100 dB nHL, tone burst 500 Hz) is fast and efficient in clinical practice to measure otolith function, predominantly utricular function.

  14. High School Teachers Win ACS Prizes

    NASA Astrophysics Data System (ADS)

    Editorial Staff, Jce

    2009-07-01

    William E. Snyder is the 2009 winner of the ACS Division of Chemical Education Central Region Award for Excellence in High School Teaching; Sally Mitchell is the winner of the 2009 James Bryant Conant Award in High School Chemistry Teaching.

  15. The AC-120: The advanced commercial transport

    NASA Technical Reports Server (NTRS)

    Duran, David; Griffin, Ernest; Mendoza, Saul; Nguyen, Son; Pickett, Tim; Noernberg, Clemm

    1993-01-01

    The main objective of this design was to fulfill a need for a new airplane to replace the aging 100 to 150 passenger, 1500 nautical mile range aircraft such as the Douglas DC9 and Boeing 737-100 airplanes. After researching the future aircraft market, conducting extensive trade studies, and analysis on different configurations, the AC-120 Advanced Commercial Transport final design was achieved. The AC-120's main design features include the incorporation of a three lifting surface configuration which is powered by two turboprop engines. The AC-120 is an economically sensitive aircraft which meets the new FM Stage Three noise requirements, and has lower NO(x) emissions than current turbofan powered airplanes. The AC-120 also improves on its contemporaries in passenger comfort, manufacturing, and operating cost.

  16. Influence of different pinning ability on harmonic susceptibilities in high-temperature superconductors

    NASA Astrophysics Data System (ADS)

    Zhang, L.; Ding, S. Y.; Liu, G. H.; Li, P.; Tang, Z.; Li, Y. B.; Huang, K.; Zhu, X. B.; Sun, Y. P.

    2012-05-01

    Influence of flux pining ability in the intragrain characterized by critical current density on the harmonics AC susceptibility is studied. A sintered superconducting sample is described by alternating weak (intergrains or weak links) and strong (intragrains) regions, which is depicted by different critical current densities Jcw and Jcs. Simulations using the flux creep model show that with the increase of the flux pinning ability of the intragrain region, a step and two peaks in the fundamental AC susceptibility as well as more peaks in the higher order even and odd harmonics are observed. Moreover, the Coles-Coles plot of χ3 may be used as a method to qualitatively estimate the values of Jc0s/Jc0w.

  17. Trapping polar molecules in an ac trap

    SciTech Connect

    Bethlem, Hendrick L.; Veldhoven, Jacqueline van; Schnell, Melanie; Meijer, Gerard

    2006-12-15

    Polar molecules in high-field seeking states cannot be trapped in static traps as Maxwell's equations do not allow a maximum of the electric field in free space. It is possible to generate an electric field that has a saddle point by superposing an inhomogeneous electric field to an homogeneous electric field. In such a field, molecules are focused along one direction, while being defocused along the other. By reversing the direction of the inhomogeneous electric field the focusing and defocusing directions are reversed. When the fields are being switched back and forth at the appropriate rate, this leads to a net focusing force in all directions. We describe possible electrode geometries for creating the desired fields and discuss their merits. Trapping of {sup 15}ND{sub 3} ammonia molecules in a cylindrically symmetric ac trap is demonstrated. We present measurements of the spatial distribution of the trapped cloud as a function of the settings of the trap and compare these to both a simple model assuming a linear force and to full three-dimensional simulations of the experiment. With the optimal settings, molecules within a phase-space volume of 270 mm{sup 3} (m/s){sup 3} remain trapped. This corresponds to a trap depth of about 5 mK and a trap volume of about 20 mm{sup 3}.

  18. Cognitive Factors in Hypnotic Susceptibility

    ERIC Educational Resources Information Center

    Palmer, Robert D.; Field, Peter B.

    1971-01-01

    This research explored the influence of cognitive variables on susceptibility to hypnosis. The three variables of concern in the present study are automatization, attention, and body experience. The results are summarized. (Author)

  19. Three-phase-to-two-phase direct AC-AC converter with three leg structure

    NASA Astrophysics Data System (ADS)

    Kwak, S.-S.

    2014-05-01

    A three-phase-to-two-phase ac-ac converter is, along with a modulation strategy based on the space vector scheme, introduced to directly drive two-phase output ac systems with high input power quality. The converter is capable of synthesising two sinusoidal output voltages with variable output frequency and arbitrary magnitude in quadrature phase-shift as well as sinusoidal input currents.

  20. Phase protection system for ac power lines

    NASA Technical Reports Server (NTRS)

    Wong, W. J. (Inventor)

    1974-01-01

    The system described provides protection for phase sensitive loads from being or remaining connected to ac power lines whenever a phase reversal occurs. It comprises a solid state phase detection circuit, a dc power relay circuit, an ac-to-dc converter for energizing the relay circuit, and a bistable four terminal transducer coupled between the phase detection circuit and the power relay circuit, for controlling both circuits.

  1. Serotonergic genes and depressive disorder in acute coronary syndrome: The Korean depression in ACS (K-DEPACS) study.

    PubMed

    Kim, Jae-Min; Stewart, Robert; Kang, Hee-Ju; Bae, Kyung-Yeol; Kim, Sung-Wan; Shin, Il-Seon; Hong, Young Joon; Ahn, Youngkeun; Jeong, Myung Ho; Park, Sung-Woo; Kim, Young-Hoon; Yoon, Jin-Sang

    2015-06-01

    Genes coding for the serotonergic pathway have been associated with depressive disorders. However, these associations have rarely been tested in acute coronary syndrome (ACS) patients vulnerable to depression. This study aimed to investigate whether polymorphisms of serotonin transporter (5-HTT) and serotonin 2a receptor (5-HTR2a) genes are associated with occurrence of depressive disorder in ACS. 969 patients with recently developed ACS were recruited at baseline, and 711 were followed 1 year thereafter. Depressive disorder was diagnosed according to DSM-IV criteria, and analysed as an outcome at baseline (prevalence), and follow up (incidence and persistence). Genotypes were ascertained for 5-HTTLPR, STin2 VNTR, 5-HTR2a 102T/C, and 5-HTR2a 1438A/G. Logistic regression models were used to investigate associations. The 5-HTTLPR s/s genotype was independently associated with depressive disorder prevalence and persistence following ACS, but no significant associations were found with the other polymorphisms. ACS patients with the 5-HTTLPR s allele are thus potentially susceptible to depressive disorder in the early phase after ACS, and with its persistence over the subsequent year.

  2. Magnetization and magnetic susceptibility of DyH3

    NASA Technical Reports Server (NTRS)

    Flood, D. J.

    1974-01-01

    The magnetization and differential magnetic susceptibility of powdered samples of DyH3 have been measured at 4.2 K in applied magnetic fields ranging to 9 Teslas. The differential magnetic susceptibility has also been studied in zero applied field as a function of temperature. The magnetization data are described by an equation of the form M = aB/(1 + bB + cB. The ratio a/b is a measure of the saturation magnetization and gives an effective moment of 5.12 Bohr magnetons per ion. The zero field susceptibility exhibits a maximum at T = 3.45 K, and an inflection point near 2.85 K. The susceptibility at 4.2 K has a 1/B squared dependence on the applied magnetic field for B approximately greater than 0.3 Teslas.

  3. Intra-wire resistance and AC loss in multi-filamentary MgB2 wires

    NASA Astrophysics Data System (ADS)

    Zhou, C.; Offringa, W.; Bergen, A.; Wessel, W. A. J.; Krooshoop, H. J. G.; Dhallé, M.; Sumption, M. D.; Collings, E. W.; Rindfleisch, M.; Tomsic, M.; ten Kate, H. H. J.; Nijhuis, A.

    2013-02-01

    Intra-wire resistance and AC loss of various multi-filamentary MgB2 wires with filaments surrounded by Nb barriers have been measured and analyzed. The intra-wire resistance is measured with a direct four-probe voltage-current method at various temperatures. The AC loss is acquired by both vibrating sample magnetometer (VSM) and magnetization measurements at 4.2 K. With the aid of finite element method simulations, the filament-to-matrix contact resistance and effective transverse resistivity are derived from direct intra-wire resistance measurements. The effective transverse resistivity values are in good agreement with those analytically derived from the AC coupling loss measurements. Surprisingly, very high values of filament-to-matrix contact resistivity are found, being 2 or 3 orders higher than commonly found for NbTi or Nb3Sn wires.

  4. Extension to AC Loss Minimization in High Temperature Superconductors

    DTIC Science & Technology

    2007-11-02

    The sample architecture was YBCO /Y2O3/CeO2:Pd/NiFe and YBCO /Y2O3/YSZ/CeO2:Pd/NiCrW. Both samples had a thickness of YBCO of 350 - 370 nm and the...our efforts on AC loss measurements of YBCO coated conductors on textured metallic substrates made in Cambridge. Several samples were prepared by pulsed...buffer structure thickness was 200 nm . The thickness of NiFe and NiCrW substrates was 35 µm and 90 µm, respectively. The measurements were performed in

  5. Experimental study of the AC magnetization loss in MgB2 superconducting wires at different temperatures

    NASA Astrophysics Data System (ADS)

    Kováč, Ján; Šouc, Ján; Kováč, Pavol

    2012-05-01

    The temperature and external AC magnetic field dependence of AC magnetization losses of MgB2 wires were studied. Temperature was varied from 18 K to 40 K and external magnetic field of frequencies 72 Hz and 144 Hz from 8 mT to 70 mT with orientation perpendicular to the wire axis. To clarify the influence of the wire construction on AC loss, single and six filament untwisted samples of length ∼50 mm were examined. For this purpose unique experimental apparatus created by the combination of original calibration-free measuring system designed for ac magnetization loss measurement and non-magnetic vacuum vessel with two-stage cryocooler for sample cooling was used. It was found, that for monofilament sample hysteretic AC losses was dominated in comparison to untwisted six-filaments sample, where coupling losses confirmed by frequency dependence were dominated.

  6. Breakthrough of 225Ac and its radionuclide daughters from an 225Ac/213Bi generator: development of new methods, quantitative characterization, and implications for clinical use.

    PubMed

    Ma, D; McDevitt, M R; Finn, R D; Scheinberg, D A

    2001-11-01

    Bisumth-213, a short-lived alpha particle emitting radionuclide, is generated from the decay of 225Ac, which has a half-life of 10 days. The development of a clinical 225Ac/213Bi generator and the preparation of a 213Bi radiolabeled antibody for radioimmunotherapy of leukemia have been reported. The 225Ac decay scheme is complex; therefore a thorough understanding of the impact of both the parent 225Ac and its daughters on radiolabeling, purification, and quantification is necessary for optimal use of the generator system. This paper reports: (i) unique new methods to measure 221Fr, 213Bi, and 209Pb, the prominent daughters of 225Ac; and (ii) a quantitative evaluation of 225Ac/213Bi generator breakthrough and the radionuclidic purity of 213Bi labeled radiopharmaceutical dose formulations. A quantitative multi-dimensional proportional scanning method was employed to distinguish and measure specific daughter radionuclides. This method combines thin layer chromatography in two perpendicular directions with attenuated collimation as a function of time for data collection and analysis. Francium-221 and 213Bi eluted differentially from the generator, and 221Fr contributed minimally to unchelated 213Bi in the reaction and final products. Lead-209 was present in the reaction solution, but not strongly bound by the chelating moiety either (i) under the 213Bi labeling reaction conditions or (ii) following chelated 213Bi decay. As a consequence of incorporating several new procedures to the operation of the generator, 225Ac breakthrough in the final product was further reduced and represented a trivial contaminant in the final drug formulations.

  7. Sustained susceptibility of pink bollworm to Bt cotton in the United States.

    PubMed

    Tabashnik, Bruce E; Morin, Shai; Unnithan, Gopalan C; Yelich, Alex J; Ellers-Kirk, Christa; Harpold, Virginia S; Sisterson, Mark S; Ellsworth, Peter C; Dennehy, Timothy J; Antilla, Larry; Liesner, Leighton; Whitlow, Mike; Staten, Robert T; Fabrick, Jeffrey A; Li, Xianchun; Carrière, Yves

    2012-01-01

    Evolution of resistance by pests can reduce the benefits of transgenic crops that produce toxins from Bacillus thuringiensis (Bt) for insect control. One of the world's most important cotton pests, pink bollworm (Pectinophora gossypiella), has been targeted for control by transgenic cotton producing Bt toxin Cry1Ac in several countries for more than a decade. In China, the frequency of resistance to Cry1Ac has increased, but control failures have not been reported. In western India, pink bollworm resistance to Cry1Ac has caused widespread control failures of Bt cotton. By contrast, in the state of Arizona in the southwestern United States, monitoring data from bioassays and DNA screening demonstrate sustained susceptibility to Cry1Ac for 16 y. From 1996-2005, the main factors that delayed resistance in Arizona appear to be abundant refuges of non-Bt cotton, recessive inheritance of resistance, fitness costs associated with resistance and incomplete resistance. From 2006-2011, refuge abundance was greatly reduced in Arizona, while mass releases of sterile pink bollworm moths were made to delay resistance as part of a multi-tactic eradication program. Sustained susceptibility of pink bollworm to Bt cotton in Arizona has provided a cornerstone for the pink bollworm eradication program and for integrated pest management in cotton. Reduced insecticide use against pink bollworm and other cotton pests has yielded economic benefits for growers, as well as broad environmental and health benefits. We encourage increased efforts to combine Bt crops with other tactics in integrated pest management programs.

  8. 21 CFR 886.1630 - AC-powered photostimulator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered photostimulator. 886.1630 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1630 AC-powered photostimulator. (a) Identification. An AC-powered photostimulator is an AC-powered device intended to provide light stimulus...

  9. 21 CFR 886.1630 - AC-powered photostimulator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false AC-powered photostimulator. 886.1630 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1630 AC-powered photostimulator. (a) Identification. An AC-powered photostimulator is an AC-powered device intended to provide light stimulus...

  10. 21 CFR 886.1850 - AC-powered slitlamp biomicroscope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered slitlamp biomicroscope. 886.1850... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1850 AC-powered slitlamp biomicroscope. (a) Identification. An AC-powered slitlamp biomicroscope is an AC-powered device that is...

  11. 21 CFR 886.1850 - AC-powered slitlamp biomicroscope.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false AC-powered slitlamp biomicroscope. 886.1850... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1850 AC-powered slitlamp biomicroscope. (a) Identification. An AC-powered slitlamp biomicroscope is an AC-powered device that is...

  12. 21 CFR 888.1240 - AC-powered dynamometer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240...) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a) Identification. An AC-powered dynamometer is an AC-powered device intended for medical purposes to...

  13. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  14. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  15. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  16. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  17. 21 CFR 886.4440 - AC-powered magnet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false AC-powered magnet. 886.4440 Section 886.4440 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4440 AC-powered magnet. (a) Identification. An AC-powered magnet is an AC-powered device that generates a magnetic field intended to find and...

  18. 21 CFR 888.1240 - AC-powered dynamometer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false AC-powered dynamometer. 888.1240 Section 888.1240...) MEDICAL DEVICES ORTHOPEDIC DEVICES Diagnostic Devices § 888.1240 AC-powered dynamometer. (a) Identification. An AC-powered dynamometer is an AC-powered device intended for medical purposes to...

  19. AC Impedance Studies on Metal/Nanoporous Silicon/ p-Silicon Structures

    NASA Astrophysics Data System (ADS)

    Mabrook, M. F.; Ray, A. K.

    2017-04-01

    Alternating current (AC) impedance measurements have been performed on 10- to 15- μm thick porous silicon layers on a (100) p-type silicon ( p(+)Si) substrate with the aluminium (Al) top electrode in a sandwich configuration in the range of 20 Hz-1 MHz and in the temperature ranging between 152 K and 292 K. The ac conductivity σ ac was found to increase with frequency f according to the universal power law: σ_{{ac}} = Afs where the exponent s is a frequency and temperature-dependent quantity. A hopping process is found to be dominant at low temperatures and high frequencies, while a thermally activated free band process is responsible for conduction at higher temperatures. Capacitance is found to decrease with frequency but increase with temperature. Frequency dependence of the loss tangent is observed with a temperature-dependent minimum value.

  20. AC Impedance Studies on Metal/Nanoporous Silicon/p-Silicon Structures

    NASA Astrophysics Data System (ADS)

    Mabrook, M. F.; Ray, A. K.

    2016-11-01

    Alternating current (AC) impedance measurements have been performed on 10- to 15-μm thick porous silicon layers on a (100) p-type silicon (p(+)Si) substrate with the aluminium (Al) top electrode in a sandwich configuration in the range of 20 Hz-1 MHz and in the temperature ranging between 152 K and 292 K. The ac conductivity σ ac was found to increase with frequency f according to the universal power law: σ_{ac} = Afs where the exponent s is a frequency and temperature-dependent quantity. A hopping process is found to be dominant at low temperatures and high frequencies, while a thermally activated free band process is responsible for conduction at higher temperatures. Capacitance is found to decrease with frequency but increase with temperature. Frequency dependence of the loss tangent is observed with a temperature-dependent minimum value.

  1. Depinning of flux lines and AC losses in magnet-superconductor levitation system

    SciTech Connect

    Terentiev, A. N.; Hull, J. R.; De Long, L. E.

    1999-11-29

    The AC loss characteristics of a magnet-superconductor system were studied with the magnet fixed to the free end of an oscillating cantilever located near a stationary melt-textured YBCO pellet. Below a threshold AC field amplitude {approx}2Oe, the dissipation of the oscillator is amplitude-independent, characteristic of a linear, non-hysteretic regime. Above threshold,dissipation increases with amplitude, reflecting the depinning and hysteretic motion of flux lines. The threshold AC field is an order of magnitude higher than that measured for the same YBCO material via AC susceptometry in a uniform DC magnetic field, A partial lock-in of flux lines between YBCO ab planes is proposed as the mechanism for the substantial increase of the depinning threshold.

  2. Antimicrobial susceptibility and susceptibility testing of Mycoplasma hominis: a review.

    PubMed

    Bygdeman, S M; Mårdh, P A

    1983-01-01

    The determination of the minimal growth-inhibiting concentration (MIC), the minimal metabolism-inhibiting concentration (MMC), and the minimal mycoplasmacidal concentration (MCC) of various antimicrobial compounds for Mycoplasma hominis is influenced by the pH of the test media, the inoculum size, and the incubation time, although each of these factors generally do not affect the minimal concentration more than fourfold. M. hominis is resistant to beta-lactam antibiotics, vancomycin, sulfonamides, trimethoprim, and polymyxin B. There are great differences in the susceptibility of M. hominis to various macrolide antibiotics. Thus the organism is resistant to erythromycin and oleandomycin, moderately resistant to tylosin and spiramycin, susceptible to josamycin as well as to another macrolide drug, labelled M-4365G. M. hominis is also highly susceptible to the macrolide-like compound rosaramicin and to the tetracyclines (although resistant strains occur). It is susceptible to lincomycin and clindamycin, and moderately susceptible to chloramphenicol and rifampicin. The aminoglycosides have limited activity against M. hominis.

  3. AC Electrokinetics of Physiological Fluids for Biomedical Applications.

    PubMed

    Lu, Yi; Liu, Tingting; Lamanda, Ariana C; Sin, Mandy L Y; Gau, Vincent; Liao, Joseph C; Wong, Pak Kin

    2015-12-01

    Alternating current (AC) electrokinetics is a collection of processes for manipulating bulk fluid mass and embedded objects with AC electric fields. The ability of AC electrokinetics to implement the major microfluidic operations, such as pumping, mixing, concentration, and separation, makes it possible to develop integrated systems for clinical diagnostics in nontraditional health care settings. The high conductivity of physiological fluids presents new challenges and opportunities for AC electrokinetics-based diagnostic systems. In this review, AC electrokinetic phenomena in conductive physiological fluids are described followed by a review of the basic microfluidic operations and the recent biomedical applications of AC electrokinetics. The future prospects of AC electrokinetics for clinical diagnostics are presented.

  4. AC Electrokinetics of Physiological Fluids for Biomedical Applications

    PubMed Central

    Lu, Yi; Liu, Tingting; Lamanda, Ariana C.; Sin, Mandy L Y; Gau, Vincent; Liao, Joseph C.; Wong, Pak Kin

    2016-01-01

    AC electrokinetics is a collection of processes for manipulating bulk fluid mass and embedded objects with AC electric fields. The ability of AC electrokinetics to implement the major microfluidic operations, such as pumping, mixing, concentration and separation, makes it possible to develop integrated systems for clinical diagnostics in non-traditional healthcare settings. The high conductivity of physiological fluids presents new challenges and opportunities for AC electrokinetics based diagnostic systems. In this review, AC electrokinetic phenomena in conductive physiological fluids are described followed by a review of the basic microfluidic operations and the recent biomedical applications of AC electrokinetics. The future prospects of AC electrokinetics for clinical diagnostics are presented. PMID:25487557

  5. AC Conductivity and Dielectric Properties of Borotellurite Glass

    NASA Astrophysics Data System (ADS)

    Taha, T. A.; Azab, A. A.

    2016-10-01

    Borotellurite glasses with formula 60B2O3-10ZnO-(30 - x)NaF- xTeO2 ( x = 0 mol.%, 5 mol.%, 10 mol.%, and 15 mol.%) have been synthesized by thermal melting. X-ray diffraction (XRD) analysis confirmed that the glasses were amorphous. The glass density ( ρ) was determined by the Archimedes method at room temperature. The density ( ρ) and molar volume ( V m) were found to increase with increasing TeO2 content. The direct-current (DC) conductivity was measured in the temperature range from 473 K to 623 K, in which the electrical activation energy of ionic conduction increased from 0.27 eV to 0.48 eV with increasing TeO2 content from 0 mol.% to 15 mol.%. The dielectric parameters and alternating-current (AC) conductivity ( σ ac) were investigated in the frequency range from 1 kHz to 1 MHz and temperature range from 300 K to 633 K. The AC conductivity and dielectric constant decreased with increasing TeO2 content from 0 mol.% to 15 mol.%.

  6. 78 FR 49318 - Availability of Draft Advisory Circular (AC) 90-106A and AC 20-167A

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-13

    ... Federal Aviation Administration Availability of Draft Advisory Circular (AC) 90-106A and AC 20- 167A...: This notice announces the availability of draft Advisory Circular (AC) 90-106A, Enhanced Flight Vision Systems and draft AC 20- 167A, Airworthiness Approval of Enhanced Vision System, Synthetic Vision...

  7. Adolescent Susceptibility to Peer Influence in Sexual Situations

    PubMed Central

    Widman, Laura; Choukas-Bradley, Sophia; Helms, Sarah W.; Prinstein, Mitchell J.

    2016-01-01

    Purpose One consistent predictor of adolescents’ engagement in sexual risk behavior is their belief that peers are engaging in similar behavior; however, not all youth are equally susceptible to these peer influence effects. Understanding individual differences in susceptibility to peer influence is critical to identifying adolescents at risk for negative health outcomes. The purpose of this project was to identify predictors of susceptibility to peer influence using a novel performance-based measure of sexual risk-taking. Methods Participants were 300 early adolescents (Mage=12.6; 53% female; 44% Caucasian) who completed 1) a pretest assessment of demographics, sexual attitudes, and hypothetical scenarios measuring the likelihood of engaging in sexual risk behavior, and 2) a subsequent experimental procedure that simulated an internet chat room in which youth believed they were communicating with peers regarding these same hypothetical scenarios. In reality, these “peers” were computer-programmed e-confederates. Changes in responses to the sexual scenarios in the private pretest versus during the public chat room provided a performance-based measure of peer influence susceptibility. Results In total, 78% of youth provided more risky responses in the chat room than in pretest. The most robust predictor of this change was gender, with boys significantly more susceptible to peer influence than girls. Significant interactions also were noted, with greater susceptibility among boys with later pubertal development and African American boys. Conclusion Results confirm that not all youth are equally susceptible to peer influence. Consistent with sexual script theory, boys evidence greater susceptibility to social pressure regarding sexual behavior than girls. PMID:26794431

  8. Human variability and susceptibility to trichloroethylene.

    PubMed Central

    Pastino, G M; Yap, W Y; Carroquino, M

    2000-01-01

    Although humans vary in their response to chemicals, comprehensive measures of susceptibility have generally not been incorporated into human risk assessment. The U.S. EPA dose-response-based risk assessments for cancer and the RfD/RfC (reference dose-reference concentration) approach for noncancer risk assessments are assumed to protect vulnerable human subgroups. However, these approaches generally rely on default assumptions and do not consider the specific biological basis for potential susceptibility to a given toxicant. In an effort to focus more explicitly on this issue, this article addresses biological factors that may affect human variability and susceptibility to trichloroethylene (TCE), a widely used halogenated industrial solvent. In response to Executive Order 13045, which requires federal agencies to make protection of children a high priority in implementing their policies and to take special risks to children into account when developing standards, this article examines factors that may affect risk of exposure to TCE in children. The influence of genetics, sex, altered health state, coexposure to alcohol, and enzyme induction on TCE toxicity are also examined. PMID:10807552

  9. Irreversibility Line Measurement and Vortex Dynamics in High Magnetic Fields in Ni- and Co-Doped Iron Pnictide Bulk Superconductors

    DOE PAGES

    Nikolo, Martin; Singleton, John; Zapf, Vivien S.; ...

    2016-07-20

    The de-pinning or irreversibility lines were determined by ac susceptibility, magnetization, radio-frequency proximity detector oscillator (PDO), and resistivity methods in Ba(Fe0.92Co0.08)2As2 ( Tc = 23.2 K), Ba(Fe0.95Ni0.05)2As2 ( Tc = 20.4 K), and Ba(Fe0.94Ni0.06)2As2 ( Tc = 18.5 K) bulk superconductors in ac, dc, and pulsed magnetic fields up to 65 T. A new method of extracting the irreversibility fields from the radio-frequency proximity detector oscillator induction technique is described. Wide temperature broadening of the irreversibility lines, for any given combination of ac and dc fields, is dependent on the time frame of measurement. Increasing the magnetic field sweep ratemore » (dH/dt) shifts the irreversibility lines to higher temperatures up to about dH/d t = 40,000 Oe/s; for higher dH/dt, there is little impact on the irreversibility line. There is an excellent data match between the irreversibility fields obtained from magnetization hysteresis loops, PDO, and ac susceptibility measurements, but not from resistivity measurements in these materials. Lower critical field vs. temperature phase diagrams are measured. Their very low values near 0 T indicate that these materials are in mixed state in nonzero magnetic fields, and yet the strength of the vortex pinning enables very high irreversibility fields, as high as 51 T at 1.5 K for the Ba(Fe0.92Co0.08)2As2 polycrystalline sample, showing a promise for liquid helium temperature applications.« less

  10. Susceptibility Genes in Thyroid Autoimmunity

    PubMed Central

    Ban, Yoshiyuki; Tomer, Yaron

    2005-01-01

    The autoimmune thyroid diseases (AITD) are complex diseases which are caused by an interaction between susceptibility genes and environmental triggers. Genetic susceptibility in combination with external factors (e.g. dietary iodine) is believed to initiate the autoimmune response to thyroid antigens. Abundant epidemiological data, including family and twin studies, point to a strong genetic influence on the development of AITD. Various techniques have been employed to identify the genes contributing to the etiology of AITD, including candidate gene analysis and whole genome screening. These studies have enabled the identification of several loci (genetic regions) that are linked with AITD, and in some of these loci, putative AITD susceptibility genes have been identified. Some of these genes/loci are unique to Graves' disease (GD) and Hashimoto's thyroiditis (HT) and some are common to both the diseases, indicating that there is a shared genetic susceptibility to GD and HT. The putative GD and HT susceptibility genes include both immune modifying genes (e.g. HLA, CTLA-4) and thyroid specific genes (e.g. TSHR, Tg). Most likely, these loci interact and their interactions may influence disease phenotype and severity. PMID:15712599

  11. Fenticonazole activity measured by the methods of the European Committee on Antimicrobial Susceptibility Testing and CLSI against 260 Candida vulvovaginitis isolates from two European regions and annotations on the prevalent genotypes.

    PubMed

    Antonopoulou, Stavroula; Aoun, Michel; Alexopoulos, Evangelos C; Baka, Stavroula; Logothetis, Emanuel; Kalambokas, Theodoros; Zannos, Andreas; Papadias, Konstantine; Grigoriou, Odysseas; Kouskouni, Evangelia; Velegraki, Aristea

    2009-05-01

    The activity of fenticonazole was studied against 260 West and Southeast European vulvovaginal candidiasis isolates, and low MICs were displayed. Fenticonazole was assessed by European Committee on Antimicrobial Susceptibility Testing and CLSI microdilution methods for the first time, and the results showed excellent agreement (97%) and significant interclass correlation coefficient (P < 0.0001). Also, the levels of agreement for the results for itraconazole, fluconazole, and ketoconazole were 84%, 90%, and 98% (P < 0.0001), respectively. Multilocus typing by PCR fingerprinting and subsequent cluster analysis delineated geographically associated alignments for Candida albicans and fluconazole resistance-related clusters for Candida glabrata.

  12. Fenticonazole Activity Measured by the Methods of the European Committee on Antimicrobial Susceptibility Testing and CLSI against 260 Candida Vulvovaginitis Isolates from Two European Regions and Annotations on the Prevalent Genotypes▿

    PubMed Central

    Antonopoulou, Stavroula; Aoun, Michel; Alexopoulos, Evangelos C.; Baka, Stavroula; Logothetis, Emanuel; Kalambokas, Theodoros; Zannos, Andreas; Papadias, Konstantine; Grigoriou, Odysseas; Kouskouni, Evangelia; Velegraki, Aristea

    2009-01-01

    The activity of fenticonazole was studied against 260 West and Southeast European vulvovaginal candidiasis isolates, and low MICs were displayed. Fenticonazole was assessed by European Committee on Antimicrobial Susceptibility Testing and CLSI microdilution methods for the first time, and the results showed excellent agreement (97%) and significant interclass correlation coefficient (P < 0.0001). Also, the levels of agreement for the results for itraconazole, fluconazole, and ketoconazole were 84%, 90%, and 98% (P < 0.0001), respectively. Multilocus typing by PCR fingerprinting and subsequent cluster analysis delineated geographically associated alignments for Candida albicans and fluconazole resistance-related clusters for Candida glabrata. PMID:19223627

  13. Electric field in an AC dielectric barrier discharge overlapped with a nanosecond pulse discharge

    NASA Astrophysics Data System (ADS)

    Goldberg, Benjamin M.; Shkurenkov, Ivan; Adamovich, Igor V.; Lempert, Walter R.

    2016-08-01

    The effect of ns discharge pulses on the AC barrier discharge in hydrogen in plane-to-plane geometry is studied using time-resolved measurements of the electric field in the plasma. The AC discharge was operated at a pressure of 300 Torr at frequencies of 500 and 1750 Hz, with ns pulses generated when the AC voltage was near zero. The electric field vector is measured by ps four-wave mixing technique, which generates coherent IR signal proportional to the square of electric field. Absolute calibration was done using an electrostatic (sub-breakdown) field applied to the discharge electrodes, when no plasma was generated. The results are compared with one-dimensional kinetic modeling of the AC discharge and the nanosecond pulse discharge, predicting behavior of both individual micro-discharges and their cumulative effect on the electric field distribution in the electrode gap, using stochastic averaging based on the experimental micro-discharge temporal probability distribution during the AC period. Time evolution of the electric field in the AC discharge without ns pulses, controlled by a superposition of random micro-discharges, exhibits a nearly ‘flat top’ distribution with the maximum near breakdown threshold, reproduced quite well by kinetic modeling. Adding ns pulse discharges on top of the AC voltage waveform changes the AC discharge behavior in a dramatic way, inducing transition from random micro-discharges to a more regular, near-1D discharge. In this case, reproducible volumetric AC breakdown is produced at a well-defined moment after each ns pulse discharge. During the reproducible AC breakdown, the electric field in the plasma exhibits a sudden drop, which coincides in time with a well-defined current pulse. This trend is also predicted by the kinetic model. Analysis of kinetic modeling predictions shows that this effect is caused by large-volume ionization and neutralization of surface charges on the dielectrics by ns discharge pulses. The present

  14. Design and synthesis of 225Ac radioimmunopharmaceuticals.

    PubMed

    McDevitt, Michael R; Ma, Dangshe; Simon, Jim; Frank, R Keith; Scheinberg, David A

    2002-12-01

    The alpha-particle-emitting radionuclides 213Bi, 211At, 224Ra are under investigation for the treatment of leukemias, gliomas, and ankylosing spondylitis, respectively. 213Bi and 211At were attached to monoclonal antibodies and used as targeted immunotherapeutic agents while unconjugated 224Ra chloride selectively seeks bone. 225Ac possesses favorable physical properties for radioimmunotherapy (10d half-life and 4 net alpha particles), but has a history of unfavorable radiolabeling chemistry and poor metal-chelate stability. We selected functionalized derivatives of DOTA as the most promising to pursue from out of a group of potential 225Ac chelate compounds. A two-step synthetic process employing either MeO-DOTA-NCS or 2B-DOTA-NCS as the chelating moiety was developed to attach 225Ac to monoclonal antibodies. This method was tested using several different IgG systems. The chelation reaction yield in the first step was 93+/-8% radiochemically pure (n=26). The second step yielded 225Ac-DOTA-IgG constructs that were 95+/-5% radiochemically pure (n=27) and the mean percent immunoreactivity ranged from 25% to 81%, depending on the antibody used. This process has yielded several potential novel targeted 225Ac-labeled immunotherapeutic agents that may now be evaluated in appropriate model systems and ultimately in humans.

  15. From Beamline to Scanner with 225Ac

    NASA Astrophysics Data System (ADS)

    Robertson, Andrew K. H.; Ramogida, Caterina F.; Kunz, Peter; Rodriguez-Rodriguez, Cristina; Schaffer, Paul; Sossi, Vesna

    2016-09-01

    Due to the high linear energy transfer and short range of alpha-radiation, targeted radiation therapy using alpha-emitting pharmaceuticals that successfully target small disease clusters will kill target cells with limited harm to healthy tissue, potentially treating the most aggressive forms of cancer. As the parent of a decay chain with four alpha- and two beta-decays, 225Ac is a promising candidate for such a treatment. However, this requires retention of the entire decay chain at the target site, preventing the creation of freely circulating alpha-emitters that reduce therapeutic effect and increase toxicity to non-target tissues. Two major challenges to 225Ac pharmaceutical development exist: insufficient global supply, and the difficulty of preventing toxicity by retaining the entire decay chain at the target site. While TRIUMF works towards large-scale (C i amounts) production of 225Ac, we already use our Isotope Separation On-Line facility to provide small (< 1 mCi) quantities for in-house chemistry and imaging research that aims to improve and assess 225Ac radiopharmaceutical targeting. This presentation provides an overview of this research program and the journey of 225Ac from the beamline to the scanner. This research is funded by the Natural Sciences and Engineering Research Council of Canada.

  16. Comparison of AC electronic monitoring and field data for estimating tolerance to Empoasca kraemeri (Homoptera: Cicadellidae) in common bean genotypes.

    PubMed

    Serrano, M S; Backus, E A; Cardona, C

    2000-12-01

    Two methods for estimating the tolerance of common bean genotypes to Empoasca kraemeri Ross & Moore were compared, using a yield trial carried out at Centro Internacional de Agricultura Tropical (CIAT), Cali, Colombia, versus stylet penetration tactics measured by AC electronic feeding monitors. A stylet penetration index was devised based on principal component scores of three penetration tactics identified (pulsing laceration, cell rupturing, and lancing sap ingestion), combined with knowledge of the hopperburn symptoms caused by each tactic. Tolerant genotypes, as classified by the CIAT yield index, showed significantly more unprotected yield and lower hopperburn scores than the susceptible control. They also induced performance of less pulsing laceration (the tactic considered most damaging to the plant), and more of the other two, mitigating tactics, especially cell rupturing. When index values were calculated for each genotype, stylet penetration index values matched those of the yield index for three out of five genotypes: two EMP-coded tolerant lines ('EMP 385' and 'EMP 392') and the susceptible control 'BAT 41'. Thus, for these three genotypes, all subsequent hoppereburn symptoms are predictable by the type of feeding behavior performed on them. 'Porrillo Sintético' and 'EMP 84', considered borderline genotypes by the yield index, were overestimated and underestimated respectively, by the stylet penetration index. We postulate that, for these two genotypes, plant physiological responses to feeding (either compensatory or heightened sensitivity, respectively) synergize with type of feeding performed to generate the overall hopperburn condition. This multivariate analysis of electronic monitoring data was successfully used to devise an index of resistance. The implications of using the stylet penetration index and the advantages of using electronic monitoring in a bean-breeding program are discussed.

  17. Factors influencing susceptibility to metals.

    PubMed Central

    Gochfeld, M

    1997-01-01

    Although the long-neglected field of human susceptibility to environmental toxicants is currently receiving renewed attention, there is only scant literature on factors influencing susceptibility to heavy metals. Genetic factors may influence the availability of sulfhydryl-containing compounds such as glutathione and metallothionein, which modify the distribution and toxicity of certain metals. Age and gender play a role in modifying uptake and distribution, although the mechanisms are often obscure. Concurrent exposure to divalent cations may enhance or reduce the toxicity of certain metals through competition for receptor-mediated transport or targets. Increasing use of biomarkers of exposure should greatly increase our understanding of the underlying distribution of susceptibility to various environmental agents. PMID:9255566

  18. In Vivo Quantitative Susceptibility Mapping (QSM) in Alzheimer's Disease

    PubMed Central

    Acosta-Cabronero, Julio; Williams, Guy B.; Cardenas-Blanco, Arturo; Arnold, Robert J.; Lupson, Victoria; Nestor, Peter J.

    2013-01-01

    Background This study explores the magnetostatic properties of the Alzheimer's disease brain using a recently proposed, magnetic resonance imaging, postprocessed contrast mechanism. Quantitative susceptibility mapping (QSM) has the potential to monitor in vivo iron levels by reconstructing magnetic susceptibility sources from field perturbations. However, with phase data acquired at a single head orientation, the technique relies on several theoretical approximations and requires fast-evolving regularisation strategies. Methods In this context, the present study describes a complete methodological framework for magnetic susceptibility measurements with a review of its theoretical foundations. Findings and Significance The regional and whole-brain cross-sectional comparisons between Alzheimer's disease subjects and matched controls indicate that there may be significant magnetic susceptibility differences for deep brain nuclei – particularly the putamen – as well as for posterior grey and white matter regions. The methodology and findings described suggest that the QSM method is ready for larger-scale clinical studies. PMID:24278382

  19. Is there a fundamental limit on nonlinear molecular susceptibilities?

    NASA Astrophysics Data System (ADS)

    Kuzyk, Mark G.

    2000-11-01

    Nonlinear optical materials have been the focus of studies to maximize their nonlinear optical susceptibility because of their possible applications. Complex quantum expressions are often simplified with two and three state models that consider the competition between excited states, symmetry, and bond length alternation. We ask the question: Is there a fundamental upper limit of the nonlinear susceptibility, and, can this limit be achieved? We use the Thomas-Kuhn quantum sum rules, which are general and apply to any system and find that the off-resonant diagonal components of the second and third-order susceptibilities are bounded by a function that depends on the number of electrons and the transition energy to the first excited state. A large set of measurements form the literature are all found to be bounded by this horizon function as predicted. Further improvements in susceptibilities will therefore require more creative approaches that are presently used.

  20. Susceptibility for thin ideal media and eating styles.

    PubMed

    Anschutz, Doeschka J; Engels, Rutger C M E; Van Strien, Tatjana

    2008-03-01

    This study examined the relations between susceptibility for thin ideal media and restrained, emotional and external eating, directly and indirectly through body dissatisfaction. Thin ideal media susceptibility, body dissatisfaction and eating styles were measured in a sample of 163 female students. Structural equation modelling was used for analyses, controlling for BMI. Higher susceptibility for thin ideal media was directly related to higher scores on all eating styles, and indirectly related to higher restrained and emotional eating through elevated levels of body dissatisfaction. So, thin ideal media susceptibility was not only related to restraint through body dissatisfaction, but also directly. Emotional eaters might be more vulnerable for negative affect, whereas external eaters might be more sensitive to external cues in general.

  1. AC Josephson effect applications in microwave systems

    NASA Astrophysics Data System (ADS)

    Larkin, Serguey Y.

    1996-12-01

    A complication of the tasks solving by the modem radliolocation, radionavigation and communication systems connected with the demand promotion to the resolution and accuracy of coordinates definition and increase in the volumes of transmitted information in satellite communication systems has resulted in boisterous mastering of millimeter wave bands. Success in microwave technology reached in 80' allowed such leading instrument developing companies as Hewlett Packard; EIP, lB millimeter etc. to set up an output of mm- and submm-wave bands devices and systems. It has streamlined Scientific Technological Progress in several spheres, since millimeter, through infra-red frequency range was closed to researchers for a long period of time because of the absence of necessary equipment. At present microwave devices of the short-wave part of mm- wave band and of submm- wave bands are used not only in radiolocation and communications. Unique diagnostic systems based on the analysis of the radiation parameters of different microwave sources were created. They have their application in medicine, thermonuclear energetics, radioastronomy, biology, nuclear physics, the physics of the solid state body, geology, etc. The above circumstances caused the beginning of the measuring microwave technology researches in 60 to 600 GHz frequency range: generators, power and frequency meters, spectrum analyzers. The task of working out equipment and techniques of the effective control as well as frequency and intensity measurements of the microwave signals in the investigated range is of the special interest. Here are some examples. The creation of a thermonuclear reactor in ITER project is considered to be the project of the century in the energetics sphere. One of the basic engineering tasks in the course of project realization is the creation of the diagnostic equipment realizing in real time spectrum analysis of thermonuclear plasma radiation at the so called cyclotron hannonics. Such

  2. Inherited susceptibility and radiation exposure

    SciTech Connect

    Little, J.B.

    1997-03-01

    There is continuing concern that some people in the general population may have genetic makeups that place them at particularly high risk for radiation-induced cancer. The existence of such a susceptible subpopulation would have obvious implications for the estimation of risks of radiation exposure. Although it has been long known that familial aggregations of cancer do sometimes occur, recent evidence suggests that a general genetic predisposition to cancer does not exist; most cancers occur sporadically. On the other hand, nearly 10% of the known Mendelian genetic disorders are associated with cancer. A number of these involve a familial predisposition to cancer, and some are characterized by an enhanced susceptibility to the induction of cancer by various physical and chemical carcinogens, including ionizing radiation. Such increased susceptibility will depend on several factors including the frequency of the susceptibility gene in the population and its penetrance, the strength of the predisposition, and the degree to which the cancer incidence in susceptible individuals may be increased by the carcinogen. It is now known that these cancer-predisposing genes may be responsible not only for rare familial cancer syndromes, but also for a proportion of the common cancers. Although the currently known disorders can account for only a small fraction of all cancers, they serve as models for genetic predisposition to carcinogen-induced cancer in the general population. In the present report, the author describes current knowledge of those specific disorders that are associated with an enhanced predisposition to radiation-induced cancer, and discusses how this knowledge may bear on the susceptibility to radiation-induced cancer in the general population and estimates of the risk of radiation exposure.

  3. Susceptibility of Autographa californica multiple nucleopolyhedrovirus to inhibitors of DNA replication.

    PubMed

    Thumbi, David K; Arif, Basil M; Krell, Peter J

    2007-12-01

    The objectives of this study were to develop methods to evaluate the susceptibility of the type baculovirus AcMNPV to various antiviral compounds and to select potential inhibitors for investigating baculovirus DNA replication. In concert with the classical cytopathic effects (CPE) and cytotoxicity inhibition assays, two approaches, which could be amenable for high throughput application for evaluating several classes of known antiviral compounds were developed. (i) An indirect approach based on spectrofluorimetric analysis of EGFP expression in Sf21 cells infected with a recombinant AcMNPV (AcEGFP) and (ii) a direct DNA quantitative assay based on quantitative real time PCR (qPCR). Initial CPE results suggested that of 21 compounds tested, aphidicolin, abacavir, camptothecin, (E)-5-(2-bromovinyl)-2'-deoxyuridine (BVDU), l-mimosine, hydroxyurea and phosphonoacetic acid (PAA) were selective inhibitors of AcMNPV replication. Consistent with the CPE results, the EGFP fluorescence and the qPCR of viral DNA accumulation exhibited a dose dependent depression of EGFP expression and DNA accumulation, respectively, in infected cells exposed to them. The inhibitory effects of aphidicolin, abacavir, l-mimosine and hydroxyurea on AcMNPV DNA replication were reversible. Taken together, both spectrofluorimetric and qPCR assays are suitable and rapid quantitative approaches to investigate inhibitors of baculovirus DNA replication in infected cells.

  4. Heck's disease: diagnosis and susceptibility.

    PubMed

    Bennett, Lindsey K; Hinshaw, Molly

    2009-01-01

    Focal epithelial hyperplasia, or Heck's disease, is an uncommon proliferation of oral mucosa that presents primarily in Native Central and South American populations. It presents as asymptomatic papules or nodules on the oral mucosa, gingiva, tongue, and lips. In the majority of cases, human papilloma virus 13 or 32 is detected. Factors that determine disease susceptibility are unclear, but genetics, and having the human lymphocytic antigen-DR4 (DRB1*0404) allele in particular, are thought to play a major role in disease vulnerability. We report another case of focal epithelial hyperplasia, hypothesize on disease susceptibility, and review the current understanding of this uncommon disorder.

  5. Nonlinear Susceptibility Magnitude Imaging of Magnetic Nanoparticles.

    PubMed

    Ficko, Bradley W; Giacometti, Paolo; Diamond, Solomon G

    2015-03-15

    This study demonstrates a method for improving the resolution of susceptibility magnitude imaging (SMI) using spatial information that arises from the nonlinear magnetization characteristics of magnetic nanoparticles (mNPs). In this proof-of-concept study of nonlinear SMI, a pair of drive coils and several permanent magnets generate applied magnetic fields and a coil is used as a magnetic field sensor. Sinusoidal alternating current (AC) in the drive coils results in linear mNP magnetization responses at primary frequencies, and nonlinear responses at harmonic frequencies and intermodulation frequencies. The spatial information content of the nonlinear responses is evaluated by reconstructing tomographic images with sequentially increasing voxel counts using the combined linear and nonlinear data. Using the linear data alone it is not possible to accurately reconstruct more than 2 voxels with a pair of drive coils and a single sensor. However, nonlinear SMI is found to accurately reconstruct 12 voxels (R(2) = 0.99, CNR = 84.9) using the same physical configuration. Several time-multiplexing methods are then explored to determine if additional spatial information can be obtained by varying the amplitude, phase and frequency of the applied magnetic fields from the two drive coils. Asynchronous phase modulation, amplitude modulation, intermodulation phase modulation, and frequency modulation all resulted in accurate reconstruction of 6 voxels (R(2) > 0.9) indicating that time multiplexing is a valid approach to further increase the resolution of nonlinear SMI. The spatial information content of nonlinear mNP responses and the potential for resolution enhancement with time multiplexing demonstrate the concept and advantages of nonlinear SMI.

  6. Pyruvate kinase deficiency confers susceptibility to Salmonella typhimurium infection in mice

    PubMed Central

    Roy, Marie-France; Riendeau, Noémie; Bédard, Christian; Hélie, Pierre; Min-Oo, Gundula; Turcotte, Karine; Gros, Philippe; Canonne-Hergaux, François; Malo, Danielle

    2007-01-01

    The mouse response to acute Salmonella typhimurium infection is complex, and it is under the influence of several genes, as well as environmental factors. In a previous study, we identified two novel Salmonella susceptibility loci, Ity4 and Ity5, in a (AcB61 × 129S6)F2 cross. The peak logarithm of odds score associated with Ity4 maps to the region of the liver and red blood cell (RBC)–specific pyruvate kinase (Pklr) gene, which was previously shown to be mutated in AcB61. During Plasmodium chabaudi infection, the Pklr mutation protects the mice against this parasite, as indicated by improved survival and lower peak parasitemia. Given that RBC defects have previously been associated with resistance to malaria and susceptibility to Salmonella, we hypothesized that Pklr is the gene underlying Ity4 and that it confers susceptibility to acute S. typhimurium infection in mice. Using a fine mapping approach combined with complementation studies, comparative studies, and functional analysis, we show that Pklr is the gene underlying Ity4 and that it confers susceptibility to acute S. typhimurium infection in mice through its effect on the RBC turnover and iron metabolism. PMID:17998386

  7. Numerical simulation of ac plasma arc thermodynamics

    NASA Astrophysics Data System (ADS)

    Wu, Han-Ming; Carey, G. F.; Oakes, M. E.

    1994-05-01

    A mathematical model and approximate analysis for the energy distribution of an ac plasma arc with a moving boundary is developed. A simplified electrical conductivity function is assumed so that the dynamic behavior of the arc may be determined, independent of the gas type. The model leads to a reduced set of non-linear partial differential equations which governs the quasi-steady ac arc. This system is solved numerically and it is found that convection plays an important role, not only in the temperature distribution, but also in arc disruptions. Moreover, disruptions are found to be influenced by convection only for a limited frequency range. The results of the present studies are applicable to the frequnecy range of 10-10(exp 2) Hz which includes most industry ac arc frequencies.

  8. Numerical Simulation of AC Plasma Arc Thermodynamics

    NASA Astrophysics Data System (ADS)

    Wu, Han-Ming; Carey, G. F.; Oakes, M. E.

    1994-05-01

    A mathematical model and approximate analysis for the energy distribution of an ac plasma arc with a moving boundary is developed. A simplified electrical conductivity function is assumed so that the dynamic behavior of the arc may be determined, independent of the gas type. The model leads to a reduced set of non-linear partial differential equations which governs the quasi-steady ac arc. This system is solved numerically and it is found that convection plays an important role, not only in the temperature distribution, but also in arc disruptions. Moreover, disruptions are found to be influenced by convection only for a limited frequency range. The results of the present studies are applicable to the frequency range of 10-102 Hz which includes most industry ac arc frequencies.

  9. An MRI-Compatible High Frequency AC Resistive Heating System for Homeothermic Maintenance in Small Animals

    PubMed Central

    Gomes, Ana L.; Kinchesh, Paul; Kersemans, Veerle; Allen, Philip D.; Smart, Sean C.

    2016-01-01

    Purpose To develop an MRI-compatible resistive heater, using high frequency alternating current (AC), for temperature maintenance of anaesthetised animals. Materials and Methods An MRI-compatible resistive electrical heater was formed from narrow gauge wire connected to a high frequency (10–100 kHz) AC power source. Multiple gradient echo images covering a range of echo times, and pulse-acquire spectra were acquired with the wire heater powered using high frequency AC or DC power sources and without any current flowing in order to assess the sensitivity of the MRI acquisitions to the presence of current flow through the heater wire. The efficacy of temperature maintenance using the AC heater was assessed by measuring rectal temperature immediately following induction of general anaesthesia for a period of 30 minutes in three different mice. Results Images and spectra acquired in the presence and absence of 50–100 kHz AC through the wire heater were indistinguishable, whereas DC power created field shifts and lineshape distortions. Temperature lost during induction of anaesthesia was recovered within approximately 20 minutes and a stable temperature was reached as the mouse’s temperature approached the set target. Conclusion The AC-powered wire heater maintains adequate heat input to the animal to maintain body temperature, and does not compromise image quality. PMID:27806062

  10. Transcranial Alternating Current Stimulation (tACS) Enhances Mental Rotation Performance during and after Stimulation

    PubMed Central

    Kasten, Florian H.; Herrmann, Christoph S.

    2017-01-01

    Transcranial alternating current stimulation (tACS) has been repeatedly demonstrated to modulate endogenous brain oscillations in a frequency specific manner. Thus, it is a promising tool to uncover causal relationships between brain oscillations and behavior or perception. While tACS has been shown to elicit a physiological aftereffect for up to 70 min, it remains unclear whether the effect can still be elicited if subjects perform a complex task interacting with the stimulated frequency band. In addition, it has not yet been investigated whether the aftereffect is behaviorally relevant. In the current experiment, participants performed a Shepard-like mental rotation task for 80 min. After 10 min of baseline measurement, participants received either 20 min of tACS at their individual alpha frequency (IAF) or sham stimulation (30 s tACS in the beginning of the stimulation period). Afterwards another 50 min of post-stimulation EEG were recorded. Task performance and EEG were acquired during the whole experiment. While there were no effects of tACS on reaction times or event-related-potentials (ERPs), results revealed an increase in mental rotation performance in the stimulation group as compared to sham both during and after stimulation. This was accompanied by increased ongoing alpha power and coherence as well as event-related-desynchronization (ERD) in the alpha band in the stimulation group. The current study demonstrates a behavioral and physiological aftereffect of tACS in parallel. This indicates that it is possible to elicit aftereffects of tACS during tasks interacting with the alpha band. Therefore, the tACS aftereffect is suitable to achieve an experimental manipulation. PMID:28197084

  11. Half-lives of the actinide nuclei /sup 225/Th,/sup 226/Th,/sup 223/Ac, and /sup 226/Ac

    SciTech Connect

    Miller, G.J.; McGeorge, J.C.; Anthony, I.; Owens, R.O.

    1987-07-01

    Improved values for the half-lives of the nuclei /sup 225,226/Th and /sup 223,226/Ac have been obtained in the course of an experiment on the photodisintegration of /sup 232/Th. The values of several other half-lives in the same mass region were also measured and found to be consistent with previous, but more accurate, determinations.

  12. Note: A sample holder design for sensitive magnetic measurements at high temperatures in a magnetic properties measurement system

    SciTech Connect

    Arauzo, A.; Guerrero, E.; Urtizberea, A.; Stankiewicz, J.; Rillo, C.

    2012-06-15

    A sample holder design for high temperature measurements in a commercial MPMS SQUID magnetometer from Quantum Design is presented. It fulfills the requirements for the simultaneous use of the oven and reciprocating sample option (RSO) options, thus allowing sensitive magnetic measurements up to 800 K. Alternating current susceptibility can also be measured, since the holder does not induce any phase shift relative to the ac driven field. It is easily fabricated by twisting Constantan Copyright-Sign wires into a braid nesting the sample inside. This design ensures that the sample be placed tightly into a tough holder with its orientation fixed, and prevents any sample displacement during the fast movements of the RSO transport, up to high temperatures.

  13. Susceptibility of CoFeB/AlOx/Co Magnetic Tunnel Junctions to Low-Frequency Alternating Current

    PubMed Central

    Chen, Yuan-Tsung; Chang, Zu-Gao

    2013-01-01

    This investigation studies CoFeB/AlOx/Co magnetic tunneling junction (MTJ) in the magnetic field of a low-frequency alternating current, for various thicknesses of the barrier layer AlOx. The low-frequency alternate-current magnetic susceptibilityac) and phase angle (θ) of the CoFeB/AlOx/Co MTJ are determined using an χac analyzer. The driving frequency ranges from 10 to 25,000 Hz. These multilayered MTJs are deposited on a silicon substrate using a DC and RF magnetron sputtering system. Barrier layer thicknesses are 22, 26, and 30 Å. The X-ray diffraction patterns (XRD) include a main peak at 2θ = 44.7° from hexagonal close-packed (HCP) Co with a highly (0002) textured structure, with AlOx and CoFeB as amorphous phases. The full width at half maximum (FWHM) of the Co(0002) peak, decreases as the AlOx thickness increases; revealing that the Co layer becomes more crystalline with increasing thickness. χac result demonstrates that the optimal resonance frequency (fres) that maximizes the χac value is 500 Hz. As the frequency increases to 1000 Hz, the susceptibility decreases rapidly. However, when the frequency increases over 1000 Hz, the susceptibility sharply declines, and almost closes to zero. The experimental results reveal that the mean optimal susceptibility is 1.87 at an AlOx barrier layer thickness of 30 Å because the Co(0002) texture induces magneto-anisotropy, which improves the indirect CoFeB and Co spin exchange-coupling strength and the χac value. The results concerning magnetism indicate that the magnetic characteristics are related to the crystallinity of Co.

  14. Active AC/DC control for wideband piezoelectric energy harvesting

    NASA Astrophysics Data System (ADS)

    Morel, A.; Grézaud, R.; Pillonnet, G.; Gasnier, P.; Despesse, G.; Badel, A.

    2016-11-01

    This paper proposes a simple interface circuit enabling resonant frequency tuning of highly coupled piezoelectric harvesters. This work relies on an active AC/DC architecture that introduces a tunable short-circuit sequence in order to control the phase between the piezoelectric current and voltage, allowing the emulation of a capacitive load. It is notably shown that this short-circuit time increases the harvested power when the piezoelectric operates outside of resonance. Measurements on a piezoelectric harvester exhibiting a large global coupling coefficient (k2 = 15.3%) have been realized and have proven the efficiency and potential of this technique.

  15. Electrospray mass spectrometry of NeuAc oligomers associated with the C fragment of the tetanus toxin

    SciTech Connect

    Prieto, M C; Whittal, R M; Baldwin, M A; Burlingame, A L; Balhorn, R

    2005-04-03

    The Clostridial neurotoxins, botulinum and tetanus, gain entry into neuronal cells by protein recognition involving cell specific binding sites. The sialic or N-acetylneuraminic acid (NeuAc) residues of gangliosides attached to the surface of motor neurons are the suspected recognition and interaction points with Clostridial neurotoxins, although not necessarily the only ones. We have used electrospray ionization mass spectrometry (ESIMS) to examine formation of complexes between the tetanus toxin C fragment, or targeting domain, and carbohydrates containing NeuAc groups to determine how NeuAc residues contribute to ganglioside binding. ESI-MS was used to rapidly and efficiently measure dissociation constants for a number of related NeuAc-containing carbohydrates and NeuAc oligomers, information that has helped identify the structural features of gangliosides that determine their binding to tetanus toxin. The strength of the interactions between the C fragment and (NeuAc){sub n}, are consistent with the topography of the targeting domain of tetanus toxin and the nature of its carbohydrate binding sites. The results suggest that the targeting domain of tetanus toxin contains two binding sites that can accommodate NeuAc (or a dimer). This study also shows that NeuAc must play an important role in ganglioside binding and molecular recognition, a process critical for normal cell function and one frequently exploited by toxins, bacteria and viruses to facilitate their entrance into cells.

  16. Efficacy of Genetically Modified Bt Toxins Alone and in Combinations Against Pink Bollworm Resistant to Cry1Ac and Cry2Ab

    PubMed Central

    Tabashnik, Bruce E.; Fabrick, Jeffrey A.; Unnithan, Gopalan C.; Yelich, Alex J.; Masson, Luke; Zhang, Jie; Bravo, Alejandra; Soberón, Mario

    2013-01-01

    Evolution of resistance in pests threatens the long-term efficacy of insecticidal proteins from Bacillus thuringiensis (Bt) used in sprays and transgenic crops. Previous work showed that genetically modified Bt toxins Cry1AbMod and Cry1AcMod effectively countered resistance to native Bt toxins Cry1Ab and Cry1Ac in some pests, including pink bollworm (Pectinophora gossypiella). Here we report that Cry1AbMod and Cry1AcMod were also effective against a laboratory-selected strain of pink bollworm resistant to Cry2Ab as well as to Cry1Ab and Cry1Ac. Resistance ratios based on the concentration of toxin killing 50% of larvae for the resistant strain relative to a susceptible strain were 210 for Cry2Ab, 270 for Cry1Ab, and 310 for Cry1Ac, but only 1.6 for Cry1AbMod and 2.1 for Cry1AcMod. To evaluate the interactions among toxins, we tested combinations of Cry1AbMod, Cry1Ac, and Cry2Ab. For both the resistant and susceptible strains, the net results across all concentrations tested showed slight but significant synergism between Cry1AbMod and Cry2Ab, whereas the other combinations of toxins did not show consistent synergism or antagonism. The results suggest that the modified toxins might be useful for controlling populations of pink bollworm resistant to Cry1Ac, Cry2Ab, or both. PMID:24244692

  17. A multifrequency eletromagnetic applicator with an integrated AC magnetometer for magnetic hyperthermia experiments

    NASA Astrophysics Data System (ADS)

    Garaio, E.; Collantes, J. M.; Plazaola, F.; Garcia, J. A.; Castellanos-Rubio, I.

    2014-11-01

    In the present paper, a lab-made electromagnetic applicator for magnetic hyperthermia experiments is described, fabricated and tested. The proposed device is able to measure the specific absorption rate (SAR) of nanoparticle samples at different magnetic field intensities and frequencies. Based on a variable parallel LCC resonant circuit fed by a linear power amplifier, the electromagnetic applicator is optimized to generate a controllable and homogeneous AC magnetic field in a 3.5 cm3 cylindrical volume, in a wide frequency range of 149-1030 kHz with high field intensities (up to 35 kA m-1 at low frequencies and up to 22 kA m-1 at high frequencies). In addition, a lab-made AC magnetometer is integrated in the electromagnetic applicator. The AC magnetometer is fully compensated to provide accurate measurements of the dynamic hysteresis cycle for nanoparticle powders or dispersions. From these dynamic hysteresis loops the SAR of the nanoparticle samples can be directly obtained. To show the capabilities of the proposed set-up, the AC hysteresis loops of two different magnetite nanoparticle samples with different sizes have been measured for various field intensities and frequencies. To our knowledge, no other work reports an electromagnetic applicator system with integrated AC magnetometer providing such characteristics in terms of frequency and intensity.

  18. Antibacterial susceptibility of plaque bacteria.

    PubMed

    Newman, M G; Hulem, C; Colgate, J; Anselmo, C

    1979-07-01

    Selected anaerobic, capnophilic and facultative bacteria isolated from patients with various forms of periodontal health and disease were tested for their susceptibility to antibiotics and antimicrobial agents. Specific bactericidal and minimum inhibitory concentrations were compared to disc zone diameters, thereby generating new standards for the potential selection of antimicrobial agents.

  19. Key comparison CCEM-K7: AC voltage ratio

    NASA Astrophysics Data System (ADS)

    Robinson, Ian; Belliss, Janet; Bryant, Stephen; Sánchez, Antonio; Álvarez, Yolanda; Schweiger, Kurt; Díaz, Carlos; Neira, Miguel; Callegaro, Luca; Lee, Rae Duk; Blanc, Isabelle; Overney, Frederic; He, XiaoBing; Ding, Cheng; Qian, ZhongTai; Waltrip, Bryan; Small, Greig; Fiander, John; Coogan, Peter; Johnson, Heather Leigh; Nakamura, Yasuhiro; Dierikx, Erik; Kishore Saxena, Anil; Saleem, Mohd; Wood, Barry; Ramm, Guenther; Eklund, Gunnar; Turhan, Enis; Semenov, Yuri

    2012-01-01

    We report the results of the international comparison of low-frequency ac voltage ratio: CCEM-K7. The participants made measurements of a unique travelling standard: an inductive voltage divider which provided the 20 ac voltage ratios chosen for the comparison. The nominal ratios chosen were: 0.1 to 0.9, 0.01 and 1/11 to 10/11. Each of the 17 participants measured the in-phase and quadrature components of all 20 ratios at a frequency of 1 kHz, and 7 laboratories made additional, optional, measurements at a frequency of 55 Hz. The report consists of two separate parts: the first part describes the comparison and provides detailed uncertainty budgets for each participant; the second part describes the method used to analyse the results, gives the results of the comparison and tabulates the raw data provided by each participant. Main text. To reach the main text of this paper, click on Final Report (a zip file containing the report as two pdf files: Part 1 and Part 2). Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Transgenic Sugarcane with a cry1Ac Gene Exhibited Better Phenotypic Traits and Enhanced Resistance against Sugarcane Borer

    PubMed Central

    Gao, Shiwu; Yang, Yingying; Wang, Chunfeng; Guo, Jinlong; Zhou, Dinggang; Wu, Qibin; Su, Yachun; Xu, Liping

    2016-01-01

    We developed sugarcane plants with improved resistance to the sugarcane borer, Diatraea saccharalis (F). An expression vector pGcry1Ac0229, harboring the cry1Ac gene and the selectable marker gene, bar, was constructed. This construct was introduced into the sugarcane cultivar FN15 by particle bombardment. Transformed plantlets were identified after selection with Phosphinothricin (PPT) and Basta. Plantlets were then screened by PCR based on the presence of cry1Ac and 14 cry1Ac positive plantlets were identified. Real-time quantitative PCR (RT-qPCR) revealed that the copy number of cry1Ac gene in the transgenic lines varied from 1 to 148. ELISA analysis showed that Cry1Ac protein levels in 7 transgenic lines ranged from 0.85 μg/FWg to 70.92 μg/FWg in leaves and 0.04 μg/FWg to 7.22 μg/FWg in stems, and negatively correlated to the rate of insect damage that ranged from 36.67% to 13.33%, respectively. Agronomic traits of six transgenic sugarcane lines with medium copy numbers were similar to the non-transgenic parental line. However, phenotype was poor in lines with high or low copy numbers. Compared to the non-transgenic control plants, all transgenic lines with medium copy numbers had relatively equal or lower sucrose yield and significantly improved sugarcane borer resistance, which lowered susceptibility to damage by insects. This suggests that the transgenic sugarcane lines harboring medium copy numbers of the cry1Ac gene may have significantly higher resistance to sugarcane borer but the sugarcane yield in these lines is similar to the non-transgenic control thus making them superior to the control lines. PMID:27093437