Science.gov

Sample records for accelerating rate calorimeter

  1. Accelerator Test of an Imaging Calorimeter

    NASA Technical Reports Server (NTRS)

    Christl, Mark J.; Adams, James H., Jr.; Binns, R. W.; Derrickson, J. H.; Fountain, W. F.; Howell, L. W.; Gregory, J. C.; Hink, P. L.; Israel, M. H.; Kippen, R. M.; Whitaker, Ann F. (Technical Monitor)

    2001-01-01

    The Imaging Calorimeter for ACCESS (ICA) utilizes a thin sampling calorimeter concept for direct measurements of high-energy cosmic rays. The ICA design uses arrays of small scintillating fibers to measure the energy and trajectory of the produced cascades. A test instrument has been developed to study the performance of this concept at accelerator energies and for comparison with simulations. Two test exposures have been completed using a CERN test beam. Some results from the accelerator tests are presented.

  2. Fast-acting calorimeter measures heat output of plasma gun accelerator

    NASA Technical Reports Server (NTRS)

    Dethlefson, R.; Larson, A. V.; Liebing, L.

    1967-01-01

    Calorimeter measures the exhaust energy from a shot of a pulsed plasma gun accelerator. It has a fast response time and requires only one measurement to determine the total energy. It uses a long ribbon of copper foil wound around a glass frame to form a reentrant cavity.

  3. Calorimeter measures high nuclear heating rates and their gradients across a reactor test hole

    NASA Technical Reports Server (NTRS)

    Burwell, D.; Coombe, J. R.; Mc Bride, J.

    1970-01-01

    Pedestal-type calorimeter measures gamma-ray heating rates from 0.5 to 7.0 watts per gram of aluminum. Nuclear heating rate is a function of cylinder temperature change, measured by four chromel-alumel thermocouples attached to the calorimeter, and known thermoconductivity of the tested material.

  4. A Simple Rate Law Experiment Using a Custom-Built Isothermal Heat Conduction Calorimeter

    ERIC Educational Resources Information Center

    Wadso, Lars; Li, Xi.

    2008-01-01

    Most processes (whether physical, chemical, or biological) produce or consume heat: measuring thermal power (the heat production rate) is therefore a typical method of studying processes. Here we describe the design of a simple isothermal heat conduction calorimeter built for use in teaching; we also provide an example of its use in simultaneously…

  5. Capillary Action may be used in feeding Particles and as calorimeters in Accelerators

    NASA Astrophysics Data System (ADS)

    Kriske, Richard

    2012-11-01

    Capillary Action was first proposed to be a Quantum Mechanical Effect by this Author. In plants it takes no work for water to travel up a tree, a flow of fluid begins when a thermal photon causes the water at the top of the column to evaporate. When the molecule evaporates a ``hole'' is transfered down the water column to the roots where apparently the ``hole'' establishes a ``current'' of ``holes'' in the manner of theory which is superior to the theory of ``solid-state'' physics. The ``hole'' can also be used in a ``path-integral'' formulation as is done in particle physics. A particle (a thermal photon) would strike the surface at the top of the column in through some ``spring'' method cause the whole column to rise--which is an interesting variation of the ``spring-in-mattress'' model used in Quantum Field Theory. Obviously a proper size tube- say a nanotube could be coupled to an Accelerator and the Quantum Field Theory Calculation of the Beam could be used to couple with the ``spring'' field available in the Tube. For the right sized tube, a Calorimeter would be the result. For other sized tubes, the beam could be fed with molecules and particles that have similar characteristics to water. Capillary Action is an example of Particle Physics seen in directly in the Classical world.

  6. Do hand-held calorimeters provide reliable and accurate estimates of resting metabolic rate?

    PubMed

    Van Loan, Marta D

    2007-12-01

    This paper provides an overview of a new technique for indirect calorimetry and the assessment of resting metabolic rate. Information from the research literature includes findings on the reliability and validity of a new hand-held indirect calorimeter as well as use in clinical and field settings. Research findings to date are of mixed results. The MedGem instrument has provided more consistent results when compared to the Douglas bag method of measuring metabolic rate. The BodyGem instrument has been shown to be less accurate when compared to standard metabolic carts. Furthermore, when the Body Gem has been used with clinical patients or with under nourished individuals the results have not been acceptable. Overall, there is not a large enough body of evidence to definitively support the use of these hand-held devices for assessment of metabolic rate in a wide variety of clinical or research environments.

  7. On the accuracy of instantaneous gas exchange rates, energy expenditure, and respiratory quotient calculations obtained in indirect whole room calorimeter

    Technology Transfer Automated Retrieval System (TEKTRAN)

    This paper analyzes the accuracy of metabolic rate calculations performed in the whole room indirect calorimeter using the molar balance equations. The equations are treated from the point of view of cause-effect relationship where the gaseous exchange rates representing the unknown causes need to b...

  8. Design Review of the D0 Central Calorimeter Module Assembly to Fermi National Accelerator Laboratory

    SciTech Connect

    Rosenfeld, M.; /Fermilab

    1987-11-01

    The D-Zero Central Calorimeter Module Assembly is a segmented ring structure consisting of an assemblage of trapezoidal modules. It is housed inside a vessel containing liquid argon. The modules contain specialized equipment for use in particle physics experiments. The design review of the D-Zero Central Calorimeter Module Assembly evaluated all major structural elements for adequacy for their design loads. They were evaluated in accordance with applicable specifications from Reference 1. The allowable stresses of the Specifications provide an approximate safety factor of 2.0 or more on failure and 1.67 on serviceability of the structure. This margin is typical of buildings, bridges, and other large structures executed in steel. To the extent that calculated stresses are less than the allowable stresses, the margin is proportionately greater. For additional conservatism to account for inherent uncertainties in estimating design loads, an arbitrary load factor of 1.25 was also applied. Design loads were calculated for deadwe1ghted plus thermal expansion, neglecting the effects of friction, and for deadweight only, considering postulated effects of friction. All of the major structural elements were found to be provisionally acceptable for their intended service and the predicted design loads. The provisions are as follows: (1) That the connect pins be fabricated of Inconel 718 or functional equivalent, instead of the originally specified Type 304 stainless steel; and (2) That conditions on bearing surfaces be modified to effectively reduce the potential coefficient of friction. The affected bearing interfaces include those between the CH, FH, and EM rings, and between the CH ring and its support members. The D-Zero Central Calorimeter Module Assembly is a segmented ring structure consisting of an assemblage of trapezoidal modules. It is housed inside a vessel containing liquid argon. The modules contain specialized equipment for use in particle physics experiments

  9. GLD Calorimeter

    NASA Astrophysics Data System (ADS)

    Takeshita, Tohru

    2006-10-01

    The GLD calorimeter, which is under study to aim as the calorimeter of ILC detector with an idea of Particle Flow, is described and discussed. The calorimeter consists of ECAL and HCAL. Both calorimeters are composed of plastic scintillator as the active medium. Fine granularity is required to achieve Particle Flow, so a small scintillator tile technique is developed with wavelength shifting fiber of MPPC read out. The requirements and our solutions for them are discussed and presented.

  10. Development of a water boil-off spent-fuel calorimeter system. [To measure decay heat generation rate

    SciTech Connect

    Creer, J.M.; Shupe, J.W. Jr.

    1981-05-01

    A calorimeter system was developed to measure decay heat generation rates of unmodified spent fuel assemblies from commercial nuclear reactors. The system was designed, fabricated, and successfully tested using the following specifications: capacity of one BWR or PWR spent fuel assembly; decay heat generation range 0.1 to 2.5 kW; measurement time of < 12 h; and an accuracy of +-10% or better. The system was acceptance tested using a dc reference heater to simulate spent fuel assembly heat generation rates. Results of these tests indicated that the system could be used to measure heat generation rates between 0.5 and 2.5 kW within +- 5%. Measurements of heat generation rates of approx. 0.1 kW were obtained within +- 15%. The calorimeter system has the potential to permit measurements of heat generation rates of spent fuel assemblies and other devices in the 12- to 14-kW range. Results of calorimetry of a Turkey Point spent fuel assembly indicated that the assembly was generating approx. 1.55 kW.

  11. [National primary standard of absorbed dose rate to water using a graphite calorimeter].

    PubMed

    Morishita, Yuichiro

    2013-01-01

    The calibration service in terms of absorbed dose to water started from 2011 after establishment of the national primary standard using a graphite calorimeter at the national metrology institute of Japan (NMIJ) and JCSS accreditation of the association for nuclear technology in medicine (ANTM). Accordingly, a new dosimetry protocol was introduced as JSMP12, in which details of the national standard were also described. This report presents a short review of the standard, a key comparison result, and a comparison result of calibration coefficients by JSMP01 and JSMP12.

  12. Risk evaluation on the basis of pressure rate measured by automatic pressure tracking adiabatic calorimeter.

    PubMed

    Iwata, Yusaku; Koseki, Hiroshi

    2008-11-15

    An automatic pressure tracking adiabatic calorimeter (APTAC) had been employed to obtain the thermokinetic and the vapor pressure data during runaway reactions. The APTAC is an adiabatic calorimeter with a large-scale sample mass and low thermal inertia, and is an extremely useful tool for assessing thermal hazards of reactive chemicals. The data obtained by the APTAC are important information for the design of the safe industrial process. The thermodynamics parameters and the gas production were discussed on the basis of the experimental data of various concentrations and weights of di-tert-butyl peroxide (DTBP)/toluene solution for the purpose of investigating the properties of the APTAC data. The thermal decomposition of DTBP was studied on the basis of the temperature data and the pressure data obtained by the APTAC. The activation energy and the frequency factor of DTBP are nearly constant and the same as the literature values in the concentrations between 20 and 60 wt.%. The pressure rise due to gas production is important data for designing the relief vent of a reactor. The time history of the gas production was investigated with various weights and concentrations. The total gas production index, which had the vapor pressure correction, was 1.0 in the decomposition of DTBP.

  13. Photon Calorimeter

    DOEpatents

    Chow, Tze-Show

    1989-01-01

    A photon calorimeter (20, 40) is provided that comprises a laminar substrate (10, 22, 42) that is uniform in density and homogeneous in atomic composition. A plasma-sprayed coating (28, 48, 52), that is generally uniform in density and homogeneous in atomic composition within the proximity of planes that are parallel to the surfaces of the substrate, is applied to either one or both sides of the laminar substrate. The plasma-sprayed coatings may be very efficiently spectrally tailored in atomic number. Thermocouple measuring junctions (30, 50, 54) are positioned within the plasma-sprayed coatings. The calorimeter is rugged, inexpensive, and equilibrates in temperature very rapidly.

  14. Photon calorimeter

    DOEpatents

    Chow, Tze-Show

    1988-04-22

    A photon calorimeter is provided that comprises a laminar substrate that is uniform in density and homogeneous in atomic composition. A plasma-sprayed coating, that is generally uniform in density and homogeneous in atomic composition within the proximity of planes that are parallel to the surfaces of the substrate, is applied to either one or both sides of the laminar substrate. The plasma-sprayed coatings may be very efficiently spectrally tailored in atomic number. Thermocouple measuring junctions, are positioned within the plasma-sprayed coatings. The calorimeter is rugged, inexpensive, and equilibrates in temperature very rapidly. 4 figs.

  15. Electromagnetic Calorimeter for Hades Experiment

    NASA Astrophysics Data System (ADS)

    Kugler, A.; Blume, C.; Czyžycki, W.; Epple, E.; Fabbietti, L.; Galatyuk, T.; Golubeva, M.; Guber, F.; Hlaváč, S.; Ivashkin, A.; Kajetanowic, M.; Kardan, B.; Koenig, W.; Lapidus, K.; Lisowski, E.; Pietraszko, J.; Reshetin, A.; Rost, A.; Salabura, P.; Sobolev, Y. G.; Svoboda, O.; Tlusty, P.; Traxler, M.

    2014-06-01

    Electromagnetic calorimeter (ECAL) is being developed to complement the dilepton spectrometer HADES currently operating at GSI Darmstadt, Germany. ECAL will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 A GeV on the beam of future accelerator SIS100@FAIR. The calorimeter will also improve the electron-hadron separation and will as well be used for the detection of photons from strange resonances in elementary and heavy ion reactions. Calorimeter modules constructed of lead glass Cherenkov counter, photomultiplier, HV divider and optical fiber are described in the detail. Two prototypes of novel front-end electronics based on TRB3 are presented. A dedicated LED based system being developed to monitor the stability of the calorimeter during beamtime is introduced as well.

  16. Secondary Emission Calorimeter (SEC)

    SciTech Connect

    Schmidt, J. J.; Northrop, Richard; Frisch, Henry; Elagin, Andrey; Ronzhin, Anatoly; Ramberg, Erik; Spiropulu, Maria; Apresyan, Artur; Xie, Si

    2014-06-25

    This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) the experimenters of University of Chicago and California Institute of Technology, who have committed to participate in beam tests to be carried out during the 2014-2015 Fermilab Test Beam Facility program. The TSW is intended primarily for the purpose of recording expectations for budget estimates and work allocations. The experimenters propose using large-area micro-channel plates assembled without the usual bialkali photocathodes as the active element in sampling calorimeters, Modules without photocathodes can be economically assembled in a glove box and then pumped and sealed using the process to construct photomultipliers, This electromagnetic calorimeter is based on W and Pb absorber plates sandwiched with detectors. Measurements can be made with bare plates and absorber inside the vacuum vessel.

  17. Development and characterization of an interferometer for calorimeter-based absorbed dose to water measurements in a medical linear accelerator

    NASA Astrophysics Data System (ADS)

    Flores-Martinez, Everardo; Malin, Martha J.; DeWerd, Larry A.

    2016-11-01

    The quantity of relevance for external beam radiotherapy is absorbed dose to water (ADW). An interferometer was built, characterized, and tested to measure ADW within the dose range of interest for external beam radiotherapy using the temperature dependence of the refractive index of water. The interferometer was used to measure radiation-induced phase shifts of a laser beam passing through a (10 × 10 × 10) cm3 water-filled glass phantom, irradiated with a 6 MV photon beam from a medical linear accelerator. The field size was (7 × 7) cm2 and the dose was measured at a depth of 5 cm in the water phantom. The intensity of the interference pattern was measured with a photodiode and was used to calculate the time-dependent phase shift curve. The system was thermally insulated to achieve temperature drifts of less than 1.5 mK/min. Data were acquired 60 s before and after the irradiation. The radiation-induced phase shifts were calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. For 200, 300, and 400 monitor units, the measured doses were 1.6 ± 0.3, 2.6 ± 0.3, and 3.1 ± 0.3 Gy, respectively. Measurements agreed within the uncertainty with dose calculations performed with a treatment planning system. The estimated type-A, k = 1 uncertainty in the measured doses was 0.3 Gy which is an order of magnitude lower than previously published interferometer-based ADW measurements.

  18. Development and characterization of an interferometer for calorimeter-based absorbed dose to water measurements in a medical linear accelerator.

    PubMed

    Flores-Martinez, Everardo; Malin, Martha J; DeWerd, Larry A

    2016-11-01

    The quantity of relevance for external beam radiotherapy is absorbed dose to water (ADW). An interferometer was built, characterized, and tested to measure ADW within the dose range of interest for external beam radiotherapy using the temperature dependence of the refractive index of water. The interferometer was used to measure radiation-induced phase shifts of a laser beam passing through a (10 × 10 × 10) cm(3) water-filled glass phantom, irradiated with a 6 MV photon beam from a medical linear accelerator. The field size was (7 × 7) cm(2) and the dose was measured at a depth of 5 cm in the water phantom. The intensity of the interference pattern was measured with a photodiode and was used to calculate the time-dependent phase shift curve. The system was thermally insulated to achieve temperature drifts of less than 1.5 mK/min. Data were acquired 60 s before and after the irradiation. The radiation-induced phase shifts were calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. For 200, 300, and 400 monitor units, the measured doses were 1.6 ± 0.3, 2.6 ± 0.3, and 3.1 ± 0.3 Gy, respectively. Measurements agreed within the uncertainty with dose calculations performed with a treatment planning system. The estimated type-A, k = 1 uncertainty in the measured doses was 0.3 Gy which is an order of magnitude lower than previously published interferometer-based ADW measurements.

  19. Heat deposition rate measurements using a graphite quasi-adiabatic calorimeter and thermoluminescent dosimeters in a fusion environment of the LOTUS facility

    SciTech Connect

    Joneja, O.P.; Rosselet, M.; Luethi, A.; Ligou, J.; Anand, R.P.; Buchillier, T.

    1995-11-01

    Heat deposition rate measurements are made by an extremely sensitive quasi-adiabatic graphite calorimeter and thermoluminescent dosimeters (TLDs) in the fusion environment of the LOTUS facility. The reproducibility of these measurements is found to be better than 1% for a dose rate more than 60 cGy/min and better than 3.8% for dose rates in the range of 6 to 60 cGy/min. The heating rates are found to vary linearly with neutron source strength. The calculation to experiment (C/E) for the bare calorimeter is found to be 1.05, whereas inside the graphite block, C/E varies from 1.11 to 1.32. These measurements are analyzed by the MCNP Monte Carlo neutron and photon transport code using the BMCCS2, PHOTXS2, and EL2 cross-section libraries. The influence of wall-returned neutrons and gammas is found to be negligible. A detailed data treatment is done with the TLD outputs to arrive at the gamma heating component at different locations in the graphite by employing the Burlin theory. The gamma production is found to be well represented in the calculations. On the other hand, measured and calculated net nuclear heating in the graphite differ considerably. A downward revision of the neutron kerma factor would be desirable. 23 refs., 8 figs., 4 tabs.

  20. A count rate based contamination control standard for electron accelerators

    SciTech Connect

    May, R.T.; Schwahn, S.O.

    1996-12-31

    Accelerators of sufficient energy and particle fluence can produce radioactivity as an unwanted byproduct. The radioactivity is typically imbedded in structural materials but may also be removable from surfaces. Many of these radionuclides decay by positron emission or electron capture; they often have long half lives and produce photons of low energy and yield making detection by standard devices difficult. The contamination control limit used throughout the US nuclear industry and the Department of Energy is 1,000 disintegrations per minute. This limit is based on the detection threshold of pancake type Geiger-Mueller probes for radionuclides of relatively high radiotoxicity, such as cobalt-60. Several radionuclides of concern at a high energy electron accelerator are compared in terms of radiotoxicity with radionuclides commonly found in the nuclear industry. Based on this comparison, a count-rate based contamination control limit and associated measurement strategy is proposed which provides adequate detection of contamination at accelerators without an increase in risk.

  1. Accelerating degradation rate of pure iron by zinc ion implantation

    PubMed Central

    Huang, Tao; Zheng, Yufeng; Han, Yong

    2016-01-01

    Pure iron has been considered as a promising candidate for biodegradable implant applications. However, a faster degradation rate of pure iron is needed to meet the clinical requirement. In this work, metal vapor vacuum arc technology was adopted to implant zinc ions into the surface of pure iron. Results showed that the implantation depth of zinc ions was about 60 nm. The degradation rate of pure iron was found to be accelerated after zinc ion implantation. The cytotoxicity tests revealed that the implanted zinc ions brought a slight increase on cytotoxicity of the tested cells. In terms of hemocompatibility, the hemolysis of zinc ion implanted pure iron was lower than 2%. However, zinc ions might induce more adhered and activated platelets on the surface of pure iron. Overall, zinc ion implantation can be a feasible way to accelerate the degradation rate of pure iron for biodegradable applications. PMID:27482462

  2. Accelerating degradation rate of pure iron by zinc ion implantation.

    PubMed

    Huang, Tao; Zheng, Yufeng; Han, Yong

    2016-12-01

    Pure iron has been considered as a promising candidate for biodegradable implant applications. However, a faster degradation rate of pure iron is needed to meet the clinical requirement. In this work, metal vapor vacuum arc technology was adopted to implant zinc ions into the surface of pure iron. Results showed that the implantation depth of zinc ions was about 60 nm. The degradation rate of pure iron was found to be accelerated after zinc ion implantation. The cytotoxicity tests revealed that the implanted zinc ions brought a slight increase on cytotoxicity of the tested cells. In terms of hemocompatibility, the hemolysis of zinc ion implanted pure iron was lower than 2%. However, zinc ions might induce more adhered and activated platelets on the surface of pure iron. Overall, zinc ion implantation can be a feasible way to accelerate the degradation rate of pure iron for biodegradable applications.

  3. Acceleration of hippocampal atrophy rates in asymptomatic amyloidosis.

    PubMed

    Andrews, K Abigail; Frost, Chris; Modat, Marc; Cardoso, M Jorge; Rowe, Chris C; Villemagne, Victor; Fox, Nick C; Ourselin, Sebastien; Schott, Jonathan M

    2016-03-01

    Increased rates of brain atrophy measured from serial magnetic resonance imaging precede symptom onset in Alzheimer's disease and may be useful outcome measures for prodromal clinical trials. Appropriate trial design requires a detailed understanding of the relationships between β-amyloid load and accumulation, and rate of brain change at this stage of the disease. Fifty-two healthy individuals (72.3 ± 6.9 years) from Australian Imaging, Biomarkers and Lifestyle Study of Aging had serial (0, 18 m, 36 m) magnetic resonance imaging, (0, 18 m) Pittsburgh compound B positron emission tomography, and clinical assessments. We calculated rates of whole brain and hippocampal atrophy, ventricular enlargement, amyloid accumulation, and cognitive decline. Over 3 years, rates of whole brain atrophy (p < 0.001), left and right hippocampal atrophy (p = 0.001, p = 0.023), and ventricular expansion (p < 0.001) were associated with baseline β-amyloid load. Whole brain atrophy rates were also independently associated with β-amyloid accumulation over the first 18 months (p = 0.003). Acceleration of left hippocampal atrophy rate was associated with baseline β-amyloid load across the cohort (p < 0.02). We provide evidence that rates of atrophy are associated with both baseline β-amyloid load and accumulation, and that there is presymptomatic, amyloid-mediated acceleration of hippocampal atrophy. Clinical trials using rate of hippocampal atrophy as an outcome measure should not assume linear decline in the presymptomatic phase.

  4. Flux Rope Acceleration and Enhanced Magnetic Reconnection Rate

    SciTech Connect

    C.Z. Cheng; Y. Ren; G.S. Choe; Y.-J. Moon

    2003-03-25

    A physical mechanism of flares, in particular for the flare rise phase, has emerged from our 2-1/2-dimensional resistive MHD simulations. The dynamical evolution of current-sheet formation and magnetic reconnection and flux-rope acceleration subject to continuous, slow increase of magnetic shear in the arcade are studied by employing a non-uniform anomalous resistivity in the reconnecting current sheet under gravity. The simulation results directly relate the flux rope's accelerated rising motion with an enhanced magnetic reconnection rate and thus an enhanced reconnection electric field in the current sheet during the flare rise phase. The simulation results provide good quantitative agreements with observations of the acceleration of flux rope, which manifests in the form of SXR ejecta or erupting filament or CMEs, in the low corona. Moreover, for the X-class flare events studied in this paper the peak reconnection electric field is about O(10{sup 2} V/m) or larger, enough to accelerate p articles to over 100 keV in a field-aligned distance of 10 km. Nonthermal electrons thus generated can produce hard X-rays, consistent with impulsive HXR emission observed during the flare rise phase.

  5. Electromagnetic Calorimeter for HADES Experiment

    NASA Astrophysics Data System (ADS)

    Rodríguez-Ramos, P.; Chlad, L.; Epple, E.; Fabbietti, L.; Galatyuk, T.; Golubeva, M.; Guber, F.; Hlaváč, S.; Ivashkin, A.; Kajetanowic, M.; Kardan, B.; Koenig, W.; Korcyl, G.; Kugler, A.; Lapidus, K.; Linev, S.; Lisowski, E.; Neiser, A.; Ott, O.; Otte, O.; Pethukov, O.; Pietraszko, J.; Reshetin, A.; Rost, A.; Salabura, P.; Sobolev, Y. G.; Svoboda, O.; Thomas, A.; Tlusty, P.; Traxler, M.

    2014-11-01

    Electromagnetic calorimeter (ECAL) is being developed to complement dilepton spectrometer HADES. ECAL will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 AGeV on the beam of future accelerator SIS100@FAIR. We will report results of the last beam test with quasi-monoenergetic photons carried out in MAMI facility at Johannes Gutenberg Universität Mainz.

  6. Performance of CDF calorimeter simulation for Tevatron Run II

    SciTech Connect

    C. Currat

    2002-09-19

    The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

  7. SpS5: Accelerating the Rate of Astronomical Discovery

    NASA Astrophysics Data System (ADS)

    Norris, Ray P.

    2010-11-01

    Special Session 5 on Accelerating the Rate of Astronomical Discovery addressed a range of potential limits to progress: paradigmatic, technological, organizational, and political. It examined each issue both from modern and historical perspectives, and drew lessons to guide future progress. A number of issues were identified which may regulate the flow of discoveries, such as the balance between large strongly-focussed projects and instruments, designed to answer the most fundamental questions confronting us, and the need to maintain a creative environment with room for unorthodox thinkers and bold, high risk, projects. Also important is the need to maintain historical and cultural perspectives, and the need to engage the minds of the most brilliant young people on the planet, regardless of their background, ethnicity, gender, or geography.

  8. GPU accelerated processing of astronomical high frame-rate videosequences

    NASA Astrophysics Data System (ADS)

    Vítek, Stanislav; Švihlík, Jan; Krasula, Lukáš; Fliegel, Karel; Páta, Petr

    2015-09-01

    Astronomical instruments located around the world are producing an incredibly large amount of possibly interesting scientific data. Astronomical research is expanding into large and highly sensitive telescopes. Total volume of data rates per night of operations also increases with the quality and resolution of state-of-the-art CCD/CMOS detectors. Since many of the ground-based astronomical experiments are placed in remote locations with limited access to the Internet, it is necessary to solve the problem of the data storage. It mostly means that current data acquistion, processing and analyses algorithm require review. Decision about importance of the data has to be taken in very short time. This work deals with GPU accelerated processing of high frame-rate astronomical video-sequences, mostly originating from experiment MAIA (Meteor Automatic Imager and Analyser), an instrument primarily focused to observing of faint meteoric events with a high time resolution. The instrument with price bellow 2000 euro consists of image intensifier and gigabite ethernet camera running at 61 fps. With resolution better than VGA the system produces up to 2TB of scientifically valuable video data per night. Main goal of the paper is not to optimize any GPU algorithm, but to propose and evaluate parallel GPU algorithms able to process huge amount of video-sequences in order to delete all uninteresting data.

  9. DnaK-Dependent Accelerated Evolutionary Rate in Prokaryotes

    PubMed Central

    Kadibalban, A. Samer; Bogumil, David; Landan, Giddy; Dagan, Tal

    2016-01-01

    Many proteins depend on an interaction with molecular chaperones in order to fold into a functional tertiary structure. Previous studies showed that protein interaction with the GroEL/GroES chaperonine and Hsp90 chaperone can buffer the impact of slightly deleterious mutations in the protein sequence. This capacity of GroEL/GroES to prevent protein misfolding has been shown to accelerate the evolution of its client proteins. Whether other bacterial chaperones have a similar effect on their client proteins is currently unknown. Here, we study the impact of DnaK (Hsp70) chaperone on the evolution of its client proteins. Evolutionary parameters were derived from comparison of the Escherichia coli proteome to 1,808,565 orthologous proteins in 1,149 proteobacterial genomes. Our analysis reveals a significant positive correlation between protein binding frequency with DnaK and evolutionary rate. Proteins with high binding affinity to DnaK evolve on average 4.3-fold faster than proteins in the lowest binding affinity class at the genus resolution. Differences in evolutionary rates of DnaK interactor classes are still significant after adjusting for possible effects caused by protein expression level. Furthermore, we observe an additive effect of DnaK and GroEL chaperones on the evolutionary rates of their common interactors. Finally, we found pronounced similarities in the physicochemical profiles that characterize proteins belonging to DnaK and GroEL interactomes. Our results thus implicate DnaK-mediated folding as a major component in shaping protein evolutionary dynamics in bacteria and supply further evidence for the long-term manifestation of chaperone-mediated folding on genome evolution. PMID:27189986

  10. Voltage stress effects on microcircuit accelerated life test failure rates

    NASA Technical Reports Server (NTRS)

    Johnson, G. M.

    1976-01-01

    The applicability of Arrhenius and Eyring reaction rate models for describing microcircuit aging characteristics as a function of junction temperature and applied voltage was evaluated. The results of a matrix of accelerated life tests with a single metal oxide semiconductor microcircuit operated at six different combinations of temperature and voltage were used to evaluate the models. A total of 450 devices from two different lots were tested at ambient temperatures between 200 C and 250 C and applied voltages between 5 Vdc and 15 Vdc. A statistical analysis of the surface related failure data resulted in bimodal failure distributions comprising two lognormal distributions; a 'freak' distribution observed early in time, and a 'main' distribution observed later in time. The Arrhenius model was shown to provide a good description of device aging as a function of temperature at a fixed voltage. The Eyring model also appeared to provide a reasonable description of main distribution device aging as a function of temperature and voltage. Circuit diagrams are shown.

  11. Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter

    DOE PAGES

    Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; ...

    2016-10-07

    We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. Here, we show that the scaling with dose rate is consistent with that expected from diffusion effects.

  12. Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter

    NASA Astrophysics Data System (ADS)

    Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; Litomin, A.; Mossolov, V.; Shumeiko, N.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Spilbeeck, A.; Alves, G. A.; Aldá Júnior, W. L.; Hensel, C.; Carvalho, W.; Chinellato, J.; De Oliveira Martins, C.; Matos Figueiredo, D.; Mora Herrera, C.; Nogima, H.; Prado Da Silva, W. L.; Tonelli Manganote, E. J.; Vilela Pereira, A.; Finger, M.; Finger, M., Jr.; Jain, S.; Khurana, R.; Adamov, G.; Tsamalaidze, Z.; Behrens, U.; Borras, K.; Campbell, A.; Costanza, F.; Gunnellini, P.; Lobanov, A.; Melzer-Pellmann, I.-A.; Muhl, C.; Roland, B.; Sahin, M.; Saxena, P.; Hegde, V.; Kothekar, K.; Pandey, S.; Sharma, S.; Beri, S. B.; Bhawandeep, B.; Chawla, R.; Kalsi, A.; Kaur, A.; Kaur, M.; Walia, G.; Bhattacharya, S.; Ghosh, S.; Nandan, S.; Purohit, A.; Sharan, M.; Banerjee, S.; Bhattacharya, S.; Bhowmik, S.; Chatterjee, S.; Das, P.; Dewanjee, R. K.; Jain, S.; Kumar, S.; Maity, M.; Majumder, G.; Mandakini, P.; Patil, M.; Sarkar, T.; Saikh, A.; Sezen, S.; Juodagalvis, A.; Afanasiev, S.; Bunin, P.; Ershov, Y.; Golutvin, I.; Malakhov, A.; Moisenz, P.; Smirnov, V.; Zarubin, A.; Chadeeva, M.; Chistov, R.; Danilov, M.; Popova, E.; Rusinov, V.; Andreev, Yu.; Dermenev, A.; Karneyeu, A.; Krasnikov, N.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Toms, M.; Zhokin, A.; Flacher, H.; Baskakov, A.; Belyaev, A.; Boos, E.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Kaminskiy, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Snigirev, A.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Leonidov, A.; Terkulov, A.; Bitioukov, S.; Elumakhov, D.; Kalinin, A.; Krychkine, V.; Mandrik, P.; Petrov, V.; Ryutin, R.; Sobol, A.; Troshin, S.; Volkov, A.; Adiguzel, A.; Bakirci, N.; Cerci, S.; Damarseckin, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Eskut, E.; Girgis, S.; Gokbulut, G.; Guler, Y.; Hos, I.; Kangal, E. E.; Kara, O.; Kayis Topaksu, A.; Kiminsu, U.; Oglakci, M.; Onengut, G.; Ozdemir, K.; Ozturk, S.; Polatoz, A.; Sunar Cerci, D.; Tali, B.; Topakli, H.; Turkcapar, S.; Zorbakir, I. S.; Zorbilmez, C.; Bilin, B.; Isildak, B.; Karapinar, G.; Murat Guler, A.; Ocalan, K.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Yetkin, E. A.; Yetkin, T.; Cankocak, K.; Sen, S.; Boyarintsev, A.; Grynyov, B.; Levchuk, L.; Popov, V.; Sorokin, P.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Charaf, O.; Cooper, S. I.; Henderson, C.; Rumerio, P.; West, C.; Arcaro, D.; Gastler, D.; Hazen, E.; Rohlf, J.; Sulak, L.; Wu, S.; Zou, D.; Hakala, J.; Heintz, U.; Kwok, K. H. M.; Laird, E.; Landsberg, G.; Mao, Z.; Gary, J. W.; Ghiasi Shirazi, S. M.; Lacroix, F.; Long, O. R.; Wei, H.; Bhandari, R.; Heller, R.; Stuart, D.; Yoo, J. H.; Apresyan, A.; Chen, Y.; Duarte, J.; Spiropulu, M.; Winn, D.; Abdullin, S.; Banerjee, S.; Chlebana, F.; Freeman, J.; Green, D.; Hare, D.; Hirschauer, J.; Joshi, U.; Lincoln, D.; Los, S.; Pedro, K.; Spalding, W. J.; Strobbe, N.; Tkaczyk, S.; Whitbeck, A.; Linn, S.; Markowitz, P.; Martinez, G.; Bertoldi, M.; Hagopian, S.; Hagopian, V.; Kolberg, T.; Baarmand, M. M.; Noonan, D.; Roy, T.; Yumiceva, F.; Bilki, B.; Clarida, W.; Debbins, P.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Miller, M.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Schmidt, I.; Snyder, C.; Southwick, D.; Tiras, E.; Yi, K.; Al-bataineh, A.; Bowen, J.; Castle, J.; McBrayer, W.; Murray, M.; Wang, Q.; Kaadze, K.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Baden, A.; Belloni, A.; Eno, S. C.; Ferraioli, C.; Grassi, T.; Hadley, N. J.; Jeng, G.-Y.; Kellogg, R. G.; Kunkle, J.; Mignerey, A.; Ricci-Tam, F.; Shin, Y. H.; Skuja, A.; Tonjes, M. B.; Yang, Z. S.; Apyan, A.; Bierwagen, K.; Brandt, S.; Klute, M.; Niu, X.; Chatterjee, R. M.; Evans, A.; Frahm, E.; Kubota, Y.; Lesko, Z.; Mans, J.; Ruckstuhl, N.; Heering, A.; Karmgard, D. J.; Musienko, Y.; Ruchti, R.; Wayne, M.; Benaglia, A. D.; Medvedeva, T.; Mei, K.; Tully, C.; Bodek, A.; de Barbaro, P.; Galanti, M.; Garcia-Bellido, A.; Khukhunaishvili, A.; Lo, K. H.; Vishnevskiy, D.; Zielinski, M.; Agapitos, A.; Chou, J. P.; Hughes, E.; Saka, H.; Sheffield, D.; Akchurin, N.; Damgov, J.; De Guio, F.; Dudero, P. R.; Faulkner, J.; Gurpinar, E.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Undleeb, S.; Volobouev, I.; Wang, Z.; Goadhouse, S.; Hirosky, R.; Wang, Y.; CMS-HCAL Collaboration

    2016-10-01

    We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects.

  13. Cerenkov fiber sampling calorimeters

    SciTech Connect

    Arrington, K.; Kefford, D.; Kennedy, J.; Pisani, R.; Sanzeni, C.; Segall, K.; Wall, D.; Winn, D.R. ); Carey, R.; Dye, S.; Miller, J.; Sulak, L.; Worstell, W. ); Efremenko, Y.; Kamyshkov, Y.; Savin, A.; Shmakov, K.; Tarkovsky, E. )

    1994-08-01

    Clear optical fibers were used as a Cerenkov sampling media in Pb (electromagnetic) and Cu (hadron) absorbers in spaghetti calorimeters, for high rate and high radiation dose experiments, such as the forward region of high energy colliders. The fiber axes were aligned close to the direction of the incident particles (1[degree]--7[degree]). The 7 [lambda] deep hadron tower contained 2.8% by volume 1.5 mm diameter core clear plastic fibers. The 27 radiation length deep electromagnetic towers had packing fractions of 6.8% and 7.2% of 1 mm diameter core quartz fibers as the active Cerenkov sampling medium. The energy resolution on electrons and pions, energy response, pulse shapes and angular studies are presented.

  14. Laboratory selection for an accelerated mosquito sexual development rate

    PubMed Central

    2011-01-01

    Background Separating males and females at the early adult stage did not ensure the virginity of females of Anopheles arabiensis (Dongola laboratory strain), whereas two years earlier this method had been successful. In most mosquito species, newly emerged males and females are not able to mate successfully. For anopheline species, a period of 24 h post-emergence is generally required for the completion of sexual maturation, which in males includes a 180° rotation of the genitalia. In this study, the possibility of an unusually shortened sexual maturity period in the laboratory-reared colony was investigated. Methods The effect of two different sex-separation methods on the virginity of females was tested: females separated as pupae or less than 16 h post-emergence were mated with males subjected to various doses of radiation. T-tests were performed to compare the two sex-separation methods. The rate of genitalia rotation was compared for laboratory-reared and wild males collected as pupae in Dongola, Sudan, and analysed by Z-tests. Spermatheca dissections were performed on females mated with laboratory-reared males to determine their insemination status. Results When the sex-separation was performed when adults were less than 16 h post-emergence, expected sterility was never reached for females mated with radio-sterilized males. Expected sterility was accomplished only when sexes were separated at the pupal stage. Observation of genitalia rotation showed that some males from the laboratory strain Dongola were able to successfully mate only 11 h after emergence and 42% of the males had already completed rotation. A small proportion of the same age females were inseminated. Wild males showed a much slower genitalia rotation rate. At 17 h post-emergence, 96% of the laboratory-reared males had completed genitalia rotation whereas none of the wild males had. Conclusion This colony has been cultured in the laboratory for over one hundred generations, and now has

  15. Diffusive shock acceleration - Acceleration rate, magnetic-field direction and the diffusion limit

    NASA Technical Reports Server (NTRS)

    Jokipii, J. R.

    1992-01-01

    This paper reviews the concept of diffusive shock acceleration, showing that the acceleration of charged particles at a collisionless shock is a straightforward consequence of the standard cosmic-ray transport equation, provided that one treats the discontinuity at the shock correctly. This is true for arbitrary direction of the upstream magnetic field. Within this framework, it is shown that acceleration at perpendicular or quasi-perpendicular shocks is generally much faster than for parallel shocks. Paradoxically, it follows also that, for a simple scattering law, the acceleration is faster for less scattering or larger mean free path. Obviously, the mean free path can not become too large or the diffusion limit becomes inapplicable. Gradient and curvature drifts caused by the magnetic-field change at the shock play a major role in the acceleration process in most cases. Recent observations of the charge state of the anomalous component are shown to require the faster acceleration at the quasi-perpendicular solar-wind termination shock.

  16. The PHENIX electromagnetic calorimeter

    SciTech Connect

    Kistenev, E.; White, S.; Belikov, S.; Kochetkov, V.

    1993-12-31

    The main features of the Phenix EM calorimeter are presented. This a Pb/scintillator calorimeter with ``shish-kebab`` fiber readout, designed for low energy electron and photon measurements. Prototype calorimeters have been built with longitudinal segmentation, {approximately} 100 psec time of flight resolution and 8% energy resolution at 1GeV/c. The laser based monitoring system which has been incorporated into large scale prototypes is described. The dependence of light yield on fiber choice and scintillator surface preparation has been studied.

  17. Near-Term Acceleration In The Rate of Temperature Change

    SciTech Connect

    Smith, Steven J.; Edmonds, James A.; Hartin, Corinne A.; Mundra, Anupriya; Calvin, Katherine V.

    2015-03-09

    Anthropogenically-driven climate changes, which are expected to impact human and natural systems, are often expressed in terms of global-mean temperature . The rate of climate change over multi-decadal scales is also important, with faster rates of change resulting in less time for human and natural systems to adapt . We find that current trends in greenhouse gas and aerosol emissions are now moving the Earth system into a regime in terms of multi-decadal rates of change that are unprecedented for at least the last 1000 years. The rate of global-mean temperature increase in the CMIP5 archive over 40-year periods increases to 0.25±0.05 (1σ) °C per decade by 2020, an average greater than peak rates of change during the previous 1-2 millennia. Regional rates of change in Europe, North America and the Arctic are higher than the global average. Research on the impacts of such near-term rates of change is urgently needed.

  18. Effects of propellant composition variables on acceleration-induced burning-rate augmentation of solid propellants

    NASA Technical Reports Server (NTRS)

    Northam, G. B.

    1972-01-01

    This work was conducted to define further the effects of propellant composition variables on the acceleration-induced burning rate augmentation of solid propellants. The rate augmentation at a given acceleration was found to be a nonlinear inverse function of the reference burning rate and not controlled by binder or catalyst type at a given reference rate. A nonaluminized propellant and a low rate double-base propellant exhibited strong transient rate augmentation due to surface pitting resulting from the retention of hot particles on the propellant surface.

  19. Effects of acceleration rate on Rayleigh-Taylor instability in elastic-plastic materials

    NASA Astrophysics Data System (ADS)

    Banerjee, Arindam; Polavarapu, Rinosh

    2016-11-01

    The effect of acceleration rate in the elastic-plastic transition stage of Rayleigh-Taylor instability in an accelerated non-Newtonian material is investigated experimentally using a rotating wheel experiment. A non-Newtonian material (mayonnaise) was accelerated at different rates by varying the angular acceleration of a rotating wheel and growth patterns of single mode perturbations with different combinations of amplitude and wavelength were analyzed. Experiments were run at two different acceleration rates to compare with experiments presented in prior years at APS DFD meetings and the peak amplitude responses are captured using a high-speed camera. Similar to the instability acceleration, the elastic-plastic transition acceleration is found to be increasing with increase in acceleration rate for a given amplitude and wavelength. The experimental results will be compared to various analytical strength models and prior experimental studies using Newtonian fluids. Authors acknowledge funding support from Los Alamos National Lab subcontract(370333) and DOE-SSAA Grant (DE-NA0001975).

  20. Limestone weathering rates accelerated by micron-scale grain detachment

    NASA Astrophysics Data System (ADS)

    Emmanuel, S.; Levenson, Y.

    2014-12-01

    The weathering rates of carbonate rocks is often thought to be controlled by chemical dissolution, although some studies have suggested that mechanical erosion could also play an important role. Quantifying the rates of the different processes has proved challenging due to the high degree of variability encountered in both field and lab settings. To determine the rates and mechanisms controlling long-term limestone weathering, we analyse a lidar scan of the Western Wall, a Roman period edifice located in Jerusalem. Weathering rates in fine-grained micritic limestone blocks are up to 2 orders of magnitude higher than the average rates estimated for coarse-grained limestone blocks at the same site. In addition, in experiments that use atomic force microscopy to image dissolving micritic limestone, we show that these higher reaction rates could be due to rapid dissolution along micron-scale grain boundaries, followed by mechanical detachment of tiny particles from the surface. Our analysis indicates that micron-scale grain detachment, rather than pure chemical dissolution, could be the dominant erosional mode for fine-grained rocks in many carbonate terrains.

  1. Magnetically Coupled Calorimeters

    NASA Technical Reports Server (NTRS)

    Bandler, Simon

    2011-01-01

    Calorimeters that utilize the temperature sensitivity of magnetism have been under development for over 20 years. They have targeted a variety of different applications that require very high resolution spectroscopy. I will describe the properties of this sensor technology that distinguish it from other low temperature detectors and emphasize the types of application to which they appear best suited. I will review what has been learned so far about the best materials, geometries, and read-out amplifiers and our understanding of the measured performance and theoretical limits. I will introduce some of the applications where magnetic calorimeters are being used and also where they are in development for future experiments. So far, most magnetic calorimeter research has concentrated on the use of paramagnets to provide temperature sensitivity; recent studies have also focused on magnetically coupled calorimeters that utilize the diamagnetic response of superconductors. I will present some of the highlights of this research, and contrast the properties of the two magnetically coupled calorimeter types.

  2. Accelerating failure rate of the ASR total hip replacement.

    PubMed

    Langton, D J; Jameson, S S; Joyce, T J; Gandhi, J N; Sidaginamale, R; Mereddy, P; Lord, J; Nargol, A V F

    2011-08-01

    There is widespread concern regarding the incidence of adverse soft-tissue reactions after metal-on-metal (MoM) hip replacement. Recent National Joint Registry data have shown clear differences in the rates of failure of different designs of hip resurfacing. Our aim was to update the failure rates related to metal debris for the Articular Surface Replacement (ASR). A total of 505 of these were implanted. Kaplan-Meier analysis showed a failure rate of 25% at six years for the ASR resurfacing and of 48.8% for the ASR total hip replacement (THR). Of 257 patients with a minimum follow-up of two years, 67 (26.1%) had a serum cobalt concentration which was greater than 7 μg/l. Co-ordinate measuring machine analysis of revised components showed that all patients suffering adverse tissue reactions in the resurfacing group had abnormal wear of the bearing surfaces. Six THR patients had relatively low rates of articular wear, but were found to have considerable damage at the trunion-taper interface. Our results suggest that wear at the modular junction is an important factor in the development of adverse tissue reactions after implantation of a large-diameter MoM THR.

  3. The ATLAS Tile Calorimeter

    SciTech Connect

    Henriques, A.

    2015-07-01

    TileCal is the Hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. It uses iron plates as absorber and plastic scintillating tiles as the active material. Scintillation light produced in the tiles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs). The resulting electronic signals from the approximately 10000 PMTs are measured and digitised every 25 ns before being transferred to off-detector data-acquisition systems. This contribution will review in a first part the performances of the calorimeter during run 1, obtained from calibration data, and from studies of the response of particles from collisions. In a second part it will present the solutions being investigated for the ongoing and future upgrades of the calorimeter electronics. (authors)

  4. MAC calorimeters and applications

    SciTech Connect

    MAC Collaboration

    1982-03-01

    The MAC detector at PEP features a large solid-angle electromagnetic/hadronic calorimeter system, augmented by magnetic charged-particle tracking, muon analysis and scintillator triggering. Its implementation in the context of electron-positron annihilation physics is described, with emphasis on the utilization of calorimetry.

  5. An Inexpensive Solution Calorimeter

    ERIC Educational Resources Information Center

    Kavanagh, Emma; Mindel, Sam; Robertson, Giles; Hughes, D. E. Peter

    2008-01-01

    We describe the construction of a simple solution calorimeter, using a miniature bead thermistor as a temperature-sensing element. This has a response time of a few seconds and made it possible to carry out a thermometric reaction in under a minute, which led to minimal heat losses. Small temperature changes of 1 K associated with enthalpies of…

  6. The rate of change of acceleration: implications to head kinematics during rear-end impacts.

    PubMed

    Hynes, Loriann M; Dickey, James P

    2008-05-01

    Whiplash is a mechanism of injury commonly associated with rear-impact vehicle collisions. To date, research has focused primarily on changes in velocity and acceleration as key factors for determining injuries due to whiplash mechanisms, but other characteristics of the acceleration pulse may be important. This study assessed whether the head acceleration response to whiplash-like perturbation profiles were affected by a change in the rate of the applied acceleration, or jerk. Twenty-one subjects were exposed to different low-velocity rear-impact whiplash-like perturbations using a precisely controlled robotic platform. The perturbations were divided into two groupings of peak acceleration (approximately 10 (high) and 5.7 (low) m/s2) and three groupings of jerk (approximately 260, 310, and 360 m/s3). These six profiles were repeated twice. Results demonstrated that the jerk magnitude significantly affected forehead acceleration in the vertical and horizontal directions. Increasing the magnitude of the platform acceleration also differentially affected the horizontal and vertical forehead accelerations. This indicates that the level of jerk influences the resulting head kinematics and should be considered when designing or interpreting experiments that are attempting to predict injury from whiplash-like perturbations.

  7. The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays.

    PubMed

    Rapp, B; Perichon, N; Denoziere, M; Daures, J; Ostrowsky, A; Bordy, J-M

    2013-05-07

    Water calorimeters are used to establish absorbed dose standards in several national metrology laboratories involved in ionizing radiation dosimetry. These calorimeters have been first used in high-energy photons of (60)Co or accelerator beams, where the depth of measurement in water is large (5 or 10 cm). The LNE-LNHB laboratory has developed a specific calorimeter which makes measurements at low depth in water (down to 0.5 cm) easier, in order to fulfil the reference conditions required by the international dosimetry protocols for medium-energy x-rays. This new calorimeter was first used to measure the absorbed dose rate in water at a depth of 2 cm for six medium-energy x-ray reference beams with a tube potential from 80 to 300 kV. The relative combined standard uncertainty obtained on the absorbed dose rate to water is lower than 0.8%. An overview of the design of the calorimeter is given, followed by a detailed description of the calculation of the correction factors and the calorimetric measurements.

  8. Baldwin effect under multipeaked fitness landscapes: Phenotypic fluctuation accelerates evolutionary rate

    NASA Astrophysics Data System (ADS)

    Saito, Nen; Ishihara, Shuji; Kaneko, Kunihiko

    2013-05-01

    Phenotypic fluctuations and plasticity can generally affect the course of evolution, a process known as the Baldwin effect. Several studies have recast this effect and claimed that phenotypic plasticity accelerates evolutionary rate (the Baldwin expediting effect); however, the validity of this claim is still controversial. In this study, we investigate the evolutionary population dynamics of a quantitative genetic model under a multipeaked fitness landscape, in order to evaluate the validity of the effect. We provide analytical expressions for the evolutionary rate and average population fitness. Our results indicate that under a multipeaked fitness landscape, phenotypic fluctuation always accelerates evolutionary rate, but it decreases the average fitness. As an extreme case of the trade-off between the rate of evolution and average fitness, phenotypic fluctuation is shown to accelerate the error catastrophe, in which a population fails to sustain a high-fitness peak. In the context of our findings, we discuss the role of phenotypic plasticity in adaptive evolution.

  9. Acceleration of the rate of ethanol fermentation by addition of nitrogen in high tannin grain sorghum

    SciTech Connect

    Mullins, J.T.; NeSmith, C.C.

    1987-01-01

    In this communication, the authors show that accelerated rates of ethanol production, comparable to sorghum varieties containing low levels of tannins and to corn, can occur without the removal of the tannins. The basis of the inhibition appears to be a lack of sufficient nitrogen in the mash for protein synthesis required to support an accelerated fermentative metabolism in Saccharomyces. No inhibition of the enzymes used for starch hydrolysis was found.

  10. The magnetized steel and scintillator calorimeters of the MINOS experiment

    NASA Astrophysics Data System (ADS)

    Minos Collaboration; Michael, D. G.; Adamson, P.; Alexopoulos, T.; Allison, W. W. M.; Alner, G. J.; Anderson, K.; Andreopoulos, C.; Andrews, M.; Andrews, R.; Arroyo, C.; Avvakumov, S.; Ayres, D. S.; Baller, B.; Barish, B.; Barker, M. A.; Barnes, P. D.; Barr, G.; Barrett, W. L.; Beall, E.; Bechtol, K.; Becker, B. R.; Belias, A.; Bergfeld, T.; Bernstein, R. H.; Bhattacharya, D.; Bishai, M.; Blake, A.; Bocean, V.; Bock, B.; Bock, G. J.; Boehm, J.; Boehnlein, D. J.; Bogert, D.; Border, P. M.; Bower, C.; Boyd, S.; Buckley-Geer, E.; Byon-Wagner, A.; Cabrera, A.; Chapman, J. D.; Chase, T. R.; Chernichenko, S. K.; Childress, S.; Choudhary, B. C.; Cobb, J. H.; Coleman, S. J.; Cossairt, J. D.; Courant, H.; Crane, D. A.; Culling, A. J.; Damiani, D.; Dawson, J. W.; de Jong, J. K.; Demuth, D. M.; de Santo, A.; Dierckxsens, M.; Diwan, M. V.; Dorman, M.; Drake, G.; Ducar, R.; Durkin, T.; Erwin, A. R.; Escobar, C. O.; Evans, J. J.; Fackler, O. D.; Falk Harris, E.; Feldman, G. J.; Felt, N.; Fields, T. H.; Ford, R.; Frohne, M. V.; Gallagher, H. R.; Gebhard, M.; Godley, A.; Gogos, J.; Goodman, M. C.; Gornushkin, Yu.; Gouffon, P.; Grashorn, E. W.; Grossman, N.; Grudzinski, J. J.; Grzelak, K.; Guarino, V.; Habig, A.; Halsall, R.; Hanson, J.; Harris, D.; Harris, P. G.; Hartnell, J.; Hartouni, E. P.; Hatcher, R.; Heller, K.; Hill, N.; Ho, Y.; Howcroft, C.; Hylen, J.; Ignatenko, M.; Indurthy, D.; Irwin, G. M.; James, C.; Jenner, L.; Jensen, D.; Joffe-Minor, T.; Kafka, T.; Kang, H. J.; Kasahara, S. M. S.; Kilmer, J.; Kim, H.; Kim, M. S.; Koizumi, G.; Kopp, S.; Kordosky, M.; Koskinen, D. J.; Kostin, M.; Kotelnikov, S. K.; Krakauer, D. A.; Kumaratunga, S.; Ladran, A. S.; Lang, K.; Laughton, C.; Lebedev, A.; Lee, R.; Lee, W. Y.; Libkind, M. A.; Liu, J.; Litchfield, P. J.; Litchfield, R. P.; Longley, N. P.; Lucas, P.; Luebke, W.; Madani, S.; Maher, E.; Makeev, V.; Mann, W. A.; Marchionni, A.; Marino, A. D.; Marshak, M. L.; Marshall, J. S.; McDonald, J.; McGowan, A. M.; Meier, J. R.; Merzon, G. I.; Messier, M. D.; Milburn, R. H.; Miller, J. L.; Miller, W. H.; Mishra, S. R.; Miyagawa, P. S.; Moore, C. D.; Morfín, J.; Morse, R.; Mualem, L.; Mufson, S.; Murgia, S.; Murtagh, M. J.; Musser, J.; Naples, D.; Nelson, C.; Nelson, J. K.; Newman, H. B.; Nezrick, F.; Nichol, R. J.; Nicholls, T. C.; Ochoa-Ricoux, J. P.; Oliver, J.; Oliver, W. P.; Onuchin, V. A.; Osiecki, T.; Ospanov, R.; Paley, J.; Paolone, V.; Para, A.; Patzak, T.; Pavlović, Ž.; Pearce, G. F.; Pearson, N.; Peck, C. W.; Perry, C.; Peterson, E. A.; Petyt, D. A.; Ping, H.; Piteira, R.; Pla-Dalmau, A.; Plunkett, R. K.; Price, L. E.; Proga, M.; Pushka, D. R.; Rahman, D.; Rameika, R. A.; Raufer, T. M.; Read, A. L.; Rebel, B.; Reyna, D. E.; Rosenfeld, C.; Rubin, H. A.; Ruddick, K.; Ryabov, V. A.; Saakyan, R.; Sanchez, M. C.; Saoulidou, N.; Schneps, J.; Schoessow, P. V.; Schreiner, P.; Schwienhorst, R.; Semenov, V. K.; Seun, S.-M.; Shanahan, P.; Shield, P. D.; Shivane, R.; Smart, W.; Smirnitsky, V.; Smith, C.; Smith, P. N.; Sousa, A.; Speakman, B.; Stamoulis, P.; Stefanik, A.; Sullivan, P.; Swan, J. M.; Symes, P. A.; Tagg, N.; Talaga, R. L.; Terekhov, A.; Tetteh-Lartey, E.; Thomas, J.; Thompson, J.; Thomson, M. A.; Thron, J. L.; Trendler, R.; Trevor, J.; Trostin, I.; Tsarev, V. A.; Tzanakos, G.; Urheim, J.; Vahle, P.; Vakili, M.; Vaziri, K.; Velissaris, C.; Verebryusov, V.; Viren, B.; Wai, L.; Ward, C. P.; Ward, D. R.; Watabe, M.; Weber, A.; Webb, R. C.; Wehmann, A.; West, N.; White, C.; White, R. F.; Wojcicki, S. G.; Wright, D. M.; Wu, Q. K.; Yan, W. G.; Yang, T.; Yumiceva, F. X.; Yun, J. C.; Zheng, H.; Zois, M.; Zwaska, R.; MINOS Collaboration

    2008-11-01

    The Main Injector Neutrino Oscillation Search (MINOS) experiment uses an accelerator-produced neutrino beam to perform precision measurements of the neutrino oscillation parameters in the "atmospheric neutrino" sector associated with muon neutrino disappearance. This long-baseline experiment measures neutrino interactions in Fermilab's NuMI neutrino beam with a near detector at Fermilab and again 735 km downstream with a far detector in the Soudan Underground Laboratory in northern Minnesota. The two detectors are magnetized steel-scintillator tracking calorimeters. They are designed to be as similar as possible in order to ensure that differences in detector response have minimal impact on the comparisons of event rates, energy spectra and topologies that are essential to MINOS measurements of oscillation parameters. The design, construction, calibration and performance of the far and near detectors are described in this paper.

  11. The magnetized steel and scintillator calorimeters of the MINOS experiment

    SciTech Connect

    Michael, : D.G.

    2008-05-01

    The Main Injector Neutrino Oscillation Search (MINOS) experiment uses an accelerator-produced neutrino beam to perform precision measurements of the neutrino oscillation parameters in the 'atmospheric neutrino' sector associated with muon neutrino disappearance. This long-baseline experiment measures neutrino interactions in Fermilab's NuMI neutrino beam with a near detector at Fermilab and again 735 km downstream with a far detector in the Soudan Underground Laboratory in northern Minnesota. The two detectors are magnetized steel-scintillator tracking calorimeters. They are designed to be as similar as possible in order to ensure that differences in detector response have minimal impact on the comparisons of event rates, energy spectra and topologies that are essential to MINOS measurements of oscillation parameters. The design, construction, calibration and performance of the far and near detectors are described in this paper.

  12. End Calorimeter Warm Tube Heater

    SciTech Connect

    Primdahl, K.; /Fermilab

    1991-08-06

    The Tevatron accelerator beam tube must pass through the End Calorimeter cryostats of the D-Zero Collider Detector. Furthermore, the End Calorimeter cryostats must be allowed to roll back forty inches without interruption of the vacuum system; hence, the Tev tube must slide through the End Calorimeter cryostat as it is rolled back. The Tev pass through the End Calorimeter can actually be thought of as a cluster of concentric tubes: Tev tube, warm (vacuum vessel) tube, IS layers of superinsulation, cold tube (argon vessel), and Inner Hadronic center support tube. M. Foley generated an ANSYS model to study the heat load. to the cryostat. during collider physics studies; that is, without operation of the heater. A sketch of the model is included in the appendix. The vacuum space and superinsulation was modeled as a thermal solid, with conductivity derived from tests performed at Fermilab. An additional estimate was done. by this author, using data supplied by NR-2. a superinsulation manufacturer. The ANSYS result and hand calculation are in close agreement. The ANSYS model was modified. by this author. to incorporate the effect of the heater. Whereas the earlier model studied steady state operation only. the revised model considers the heater-off steady state mode as the initial condition. then performs a transient analysis with a final load step for time tending towards infinity. Results show the thermal gradient as a function of time and applied voltage. It should be noted that M. Foley's model was generated for one half the warm tube. implying the tube to be symmetric. In reality. the downstream connection (relative to the collision point) attachment to the vacuum shell is via several convolutions of a 0.020-inch wall bellows; hence. a nearly adiabatic boundary condition. Accordingly. the results reported in the table reflect extrapolation of the curves to the downstream end of the tube. Using results from the ANSYS analysis, that is, tube temperature and

  13. Computed lateral rate and acceleration power spectral response of conventional and STOL airplanes to atmospheric turbulence

    NASA Technical Reports Server (NTRS)

    Lichtenstein, J. H.

    1975-01-01

    Power-spectral-density calculations were made of the lateral responses to atmospheric turbulence for several conventional and short take-off and landing (STOL) airplanes. The turbulence was modeled as three orthogonal velocity components, which were uncorrelated, and each was represented with a one-dimensional power spectrum. Power spectral densities were computed for displacements, rates, and accelerations in roll, yaw, and sideslip. In addition, the power spectral density of the transverse acceleration was computed. Evaluation of ride quality based on a specific ride quality criterion was also made. The results show that the STOL airplanes generally had larger values for the rate and acceleration power spectra (and, consequently, larger corresponding root-mean-square values) than the conventional airplanes. The ride quality criterion gave poorer ratings to the STOL airplanes than to the conventional airplanes.

  14. Radionuclide calorimeter system

    DOEpatents

    Donohoue, Thomas P.; Oertel, Christopher P.; Tyree, William H.; Valdez, Joe L.

    1991-11-26

    A circuit for measuring temperature differentials in a calorimeter is disclosed. The temperature differential between the reference element and sample element containing a radioactive material is measured via a wheatstone bridge arrangement of thermistors. The bridge is driven with an alternating current on a pulsed basis to maintain the thermal floor of the calorimeter at a low reference value. A lock-in amplifier connected to the bridge phase locks a signal from the bridge to the input pulsed AC signal to provide a DC voltage. The DC voltage is sampled over time and provided to a digital computer. The digital computer, using curve fitting algorithms, will derive a function for the sample data. From the function, an equilibrium value for the temperature may be calculated.

  15. Radionuclide calorimeter system

    DOEpatents

    Donohoue, T.P.; Oertel, C.P.; Tyree, W.H.; Valdez, J.L.

    1991-11-26

    A circuit for measuring temperature differentials in a calorimeter is disclosed. The temperature differential between the reference element and sample element containing a radioactive material is measured via a Wheatstone bridge arrangement of thermistors. The bridge is driven with an alternating current on a pulsed basis to maintain the thermal floor of the calorimeter at a low reference value. A lock-in amplifier connected to the bridge phase locks a signal from the bridge to the input pulsed AC signal to provide a DC voltage. The DC voltage is sampled over time and provided to a digital computer. The digital computer, using curve fitting algorithms, will derive a function for the sample data. From the function, an equilibrium value for the temperature may be calculated. 7 figures.

  16. The HPS electromagnetic calorimeter

    DOE PAGES

    Balossino, I.; Baltzell, N.; Battaglieri, M.; ...

    2017-02-22

    The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called "heavy photon". Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015-2016. The calorimeter's main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. Finally, the detector is a homogeneous calorimeter, made of 442 lead-tungsten (PbWOmore » $$_4$$) scintillating crystals, each read-out by an avalanche photodiode coupled to a custom trans-impedance amplifier.« less

  17. DSWA calorimeter bomb experiments

    SciTech Connect

    Cunningham, B

    1998-10-01

    Two experiments were performed in which 25 grams of TNT were detonated inside an expended detonation calorimeter bomb. The bomb had a contained volume of approximately 5.28 liters. In the first experiment, the bomb was charged with 3 atmospheres of nitrogen. In the second, it was charged with 2.58 atmospheres (23.1 psi gage) of oxygen. In each experiment pressure was monitored over a period of approximately 1200 microseconds after the pulse to the CDU. Monitoring was performed via two 10,000 psi 102AO3 PCB high frequency pressure transducers mounted symmetrically in the lid of the calorimeter bomb. Conditioners used were PCB 482As. The signals from the transducers were recorded in digital format on a multi channel Tektronix scope. The sampling frequency was 10 Mhz (10 samples per microsecond). After a period of cooling following detonation, gas samples were taken and were subsequently submitted for analysis using gas mass spectrometry. Due to a late request for post shot measurement, it was only possible to make a rough estimate of the weight of debris (carbon) remaining in the calorimeter bomb following the second experiment.

  18. An Imaging Calorimeter for Access-Concept Study

    NASA Technical Reports Server (NTRS)

    Parnell, T. A.; Adams, James H.; Binns, R. W.; Christl, M. J.; Derrickson, J. H.; Fountain, W. F.; Howell, L. W.; Gregory, J. C.; Hink, P. L.; Israel, M. H.; Whitaker, Ann F. (Technical Monitor)

    2001-01-01

    A mission concept study to define the "Advanced Cosmic-ray Composition Experiment for Space Station (ACCESS)" was sponsored by the National Aeronautics and Space Administration (NASA). The ACCESS instrument complement contains a transition radiation detector and an ionization calorimeter to measure tile spectrum of protons, helium, and heavier nuclei up to approximately 10(exp 15) eV to search for the limit of S/N shock wave acceleration, or evidence for other explanations of the spectra. Several calorimeter configurations have been studied, including the "baseline" totally active bismuth germanate instrument and sampling calorimeters utilizing various detectors. The Imaging Calorimeter for ACCESS (ICA) concept comprises a carbon target and a calorimeter using a high atomic number absorber sampled approximately each radiation length (rl) by thin scintillating fiber (SCIFI) detectors. The main features and options of the ICA instrument configuration are described in this paper. Since direct calibration is not possible over most of the energy range, the best approach must be decided from simulations of calorimeter performance extrapolated from CERN calibrations at 0.375 TeV. This paper presents results from the ICA simulations study.

  19. Advanced Thin Ionization Calorimeter (ATIC)

    NASA Technical Reports Server (NTRS)

    Wefel, John P.

    1998-01-01

    This is the final report for NASA grant NAGW-4577, "Advanced Thin Ionization Calorimeter (ATIC)". This grant covered a joint project between LSU and the University of Maryland for a Concept Study of a new type of fully active calorimeter to be used to measure the energy spectra of very high energy cosmic rays, particularly Hydrogen and Helium, to beyond 1014 eV. This very high energy region has been studied with emulsion chamber techniques, but never investigated with electronic calorimeters. Technology had advanced to the point that a fully active calorimeter based upon Bismuth Germanate (BGO) scintillating crystals appeared feasible for balloon flight (and eventually space) experiments.

  20. Deceleration and acceleration capacities of heart rate associated with heart failure with high discriminating performance.

    PubMed

    Hu, Wei; Jin, Xian; Zhang, Peng; Yu, Qiang; Yin, Guizhi; Lu, Yi; Xiao, Hongbing; Chen, Yueguang; Zhang, Dadong

    2016-03-23

    Accurate measurements of autonomic nerve regulation in heart failure (HF) were unresolved. The discriminating performance of deceleration and acceleration capacities of heart rate in HF was evaluated in 130 HF patients and 212 controls. Acceleration capacity and deceleration capacity were independent risk factors for HF in males, evaluated by multiple logistic regression analysis, with odds ratios (ORs) of 5.94 and 0.13, respectively. Acceleration capacity was also an independent risk factor for HF in females, with an OR of 8.58. Deceleration capacity was the best cardiac electrophysiological index to classify HF in males, with an area under the receiver operating characteristic curve (AUC) of 0.88. Deceleration capacity was the best classification factor of HF in females with an AUC of 0.97, significantly higher than even left ventricular ejection fraction (LVEF). Acceleration capacity also showed high performance in classifying HF in males (0.84) and females (0.92). The cut-off values of deceleration capacity for HF classification in males and females were 4.55 ms and 4.85 ms, respectively. The cut-off values of acceleration capacity for HF classification in males and females were -6.15 ms and -5.75 ms, respectively. Our study illustrates the role of acceleration and deceleration capacity measurements in the neuro-pathophysiology of HF.

  1. Deceleration and acceleration capacities of heart rate associated with heart failure with high discriminating performance

    PubMed Central

    Hu, Wei; Jin, Xian; Zhang, Peng; Yu, Qiang; Yin, Guizhi; Lu, Yi; Xiao, Hongbing; Chen, Yueguang; Zhang, Dadong

    2016-01-01

    Accurate measurements of autonomic nerve regulation in heart failure (HF) were unresolved. The discriminating performance of deceleration and acceleration capacities of heart rate in HF was evaluated in 130 HF patients and 212 controls. Acceleration capacity and deceleration capacity were independent risk factors for HF in males, evaluated by multiple logistic regression analysis, with odds ratios (ORs) of 5.94 and 0.13, respectively. Acceleration capacity was also an independent risk factor for HF in females, with an OR of 8.58. Deceleration capacity was the best cardiac electrophysiological index to classify HF in males, with an area under the receiver operating characteristic curve (AUC) of 0.88. Deceleration capacity was the best classification factor of HF in females with an AUC of 0.97, significantly higher than even left ventricular ejection fraction (LVEF). Acceleration capacity also showed high performance in classifying HF in males (0.84) and females (0.92). The cut-off values of deceleration capacity for HF classification in males and females were 4.55 ms and 4.85 ms, respectively. The cut-off values of acceleration capacity for HF classification in males and females were −6.15 ms and −5.75 ms, respectively. Our study illustrates the role of acceleration and deceleration capacity measurements in the neuro-pathophysiology of HF. PMID:27005970

  2. Accelerated tests for bounding the low dose rate radiation response of lateral PNP bipolar junction transistors

    SciTech Connect

    Witczak, S.C.; Schrimpf, R.D.; Galloway, K.F.; Schmidt, D.M.; Fleetwood, D.M.; Pease, R.L.; Coombs, W.E.; Suehle, J.S.

    1996-03-01

    Low dose rate gain degradation of lateral pnp bipolar transistors can be simulated by accelerated irradiations performed at approximately 135 degrees C. Degradation enhancement is explained by temperature- dependent radiation-induced interface trap formation above the transistor`s base.

  3. Accelerating rate calorimetry: A new technique for safety studies in lithium systems

    NASA Technical Reports Server (NTRS)

    Ebner, W. B.

    1982-01-01

    The role of exothermic reactions in battery test modes is discussed. The exothermic reactions are characterized with respect to their time-temperature and time-pressure behavior. Reactions occuring for any major exotherm were examined. The accelerating rate calorimetry methods was developed to study lithium cells susceptibility to thermal runaway reactions following certain abuse modes such as forced discharge into reversal and charging.

  4. Evolution of high-repetition-rate induction accelerators through advancements in switching

    NASA Astrophysics Data System (ADS)

    Kirbie, H. C.; Caporaso, G. J.; Newton, M. A.; Yu, S. S.

    1992-08-01

    Future applications of linear and recirculating induction accelerators include microwave sources for plasma heating and linear colliders, industrial manufacturing processes, and heavy ion fusion. These applications require pulsed sources capable of sustained operation at high pulse-repetition rates. Powering these new accelerators places severe switching demands on the source, demands that often can not be met withcommercially-available technology. Consequently, several new accelerator switching schemes have been developed at Lawrence Livermore National Laboratory (LLNL). Our transition from spark-gap technology to magnetic switching has merged the formerly independent roles of source and cell into a single system and reshaped our design methods to emphasize high efficiency. Treatment of the accelerator as a system has also enabled us to optimize new accelerator designs based on cost considerations. Presently, we are developing a technology for driving a heavy-ion induction recirculator at pulse rates exceeding 100 kHz. In this case, the switching method is all solid state and the source and cell have evolved into a unified device.

  5. Electromagnetic calorimeter for Belle II

    NASA Astrophysics Data System (ADS)

    Belle-ECL; Aulchenko, V.; Bobrov, A.; Bondar, A.; Cheon, B. G.; Eidelman, S.; Epifanov, D.; Garmash, Yu; Goh, Y. M.; Kim, S. H.; Krokovny, P.; Kuzmin, A.; Lee, I. S.; Matvienko, D.; Miyabayashi, K.; Nakamura, I.; Shebalin, V.; Shwartz, B.; Unno, Y.; Usov, Yu; Vinokurova, A.; Vorobjev, V.; Zhilich, V.; Zhulanov, V.

    2015-02-01

    The electromagnetic calorimeter of the BELLE II detector for experiments at Super B-factory SuperKEKB is briefly described. The project of the calorimeter upgrade to meet severe background conditions expected at the upgraded KEK B factory is presented.

  6. A model to calculate the induced dose rate around an 18 MV ELEKTA linear accelerator.

    PubMed

    Perrin, Bruce; Walker, Anne; Mackay, Ranald

    2003-03-07

    The dose rate due to activity induced by (gamma, n) reactions around an ELEKTA Precise accelerator running at 18 MV is reported. A model to calculate the induced dose rate for a variety of working practices has been derived and compared to the measured values. From this model, the dose received by the staff using the machine can be estimated. From measured dose rates at the face of the linear accelerator for a 10 x 10 cm2 jaw setting at 18 MV an activation coefficient per MU was derived for each of the major activation products. The relative dose rates at points around the linac head, for different energy and jaw settings, were measured. Dose rates adjacent to the patient support system and portal imager were also measured. A model to calculate the dose rate at these points was derived, and compared to those measured over a typical working week. The model was then used to estimate the maximum dose to therapists for the current working schedule on this machine. Calculated dose rates at the linac face agreed to within +/- 12% of those measured over a week, with a typical dose rate of 4.5 microSv h(-1) 2 min after the beam has stopped. The estimated maximum annual whole body dose for a treatment therapist, with the machine treating at only 18 MV, for 60000 MUs per week was 2.5 mSv. This compares well with value of 2.9 mSv published for a Clinac 21EX. A model has been derived to calculate the dose from the four dominant activation products of an ELEKTA Precise 18 MV linear accelerator. This model is a useful tool to calculate the induced dose rate around the treatment head. The model can be used to estimate the dose to the staff for typical working patterns.

  7. Accelerated high-frame-rate mouse heart cine-MRI using compressed sensing reconstruction.

    PubMed

    Motaal, Abdallah G; Coolen, Bram F; Abdurrachim, Desiree; Castro, Rui M; Prompers, Jeanine J; Florack, Luc M J; Nicolay, Klaas; Strijkers, Gustav J

    2013-04-01

    We introduce a new protocol to obtain very high-frame-rate cinematographic (Cine) MRI movies of the beating mouse heart within a reasonable measurement time. The method is based on a self-gated accelerated fast low-angle shot (FLASH) acquisition and compressed sensing reconstruction. Key to our approach is that we exploit the stochastic nature of the retrospective triggering acquisition scheme to produce an undersampled and random k-t space filling that allows for compressed sensing reconstruction and acceleration. As a standard, a self-gated FLASH sequence with a total acquisition time of 10 min was used to produce single-slice Cine movies of seven mouse hearts with 90 frames per cardiac cycle. Two times (2×) and three times (3×) k-t space undersampled Cine movies were produced from 2.5- and 1.5-min data acquisitions, respectively. The accelerated 90-frame Cine movies of mouse hearts were successfully reconstructed with a compressed sensing algorithm. The movies had high image quality and the undersampling artifacts were effectively removed. Left ventricular functional parameters, i.e. end-systolic and end-diastolic lumen surface areas and early-to-late filling rate ratio as a parameter to evaluate diastolic function, derived from the standard and accelerated Cine movies, were nearly identical.

  8. The Electromagnetic Calorimeter of the future PANDA Detector

    SciTech Connect

    Novotny, Rainer

    2006-10-27

    Experiments with a cooled antiproton beam at the future accelerator facility FAIR at GSI, Darmstadt, will be performed with the 4{pi} detector PANDA comprising a high resolution, compact and fast homogeneous electromagnetic calorimeter to detect photons between 10MeV and 10GeV energy inside a superconducting solenoid (2T). The target calorimeter comprises more than 20,000 PbWO4 crystals of significantly enhanced quality read-out with large area avalanche photodiodes at an operating temperature of -25 degree sign C. The paper describes the quality of PWO-II and illustrates the future performance based on response measurements with high-energy photons.

  9. Sensory Constraints on Birdsong Syntax: Neural Responses to Swamp Sparrow Songs with Accelerated Trill Rates.

    PubMed

    Prather, Jf; Peters, S; Mooney, R; Nowicki, S

    2012-06-01

    Both sensory and motor mechanisms can constrain behavioral performance. Sensory mechanisms may be especially important for constraining behaviors that depend on experience, such as learned birdsongs. Swamp sparrows learn to sing by imitating the song of a tutor, but sparrows fail to accurately imitate artificial tutor songs with abnormally accelerated trills, instead singing brief and rapid trills interrupted by silent gaps. This "broken syntax" has been proposed to arise from vocal-motor limitations. Here we consider whether sensory limitations exist that could also contribute to broken syntax. We tested this idea by recording auditory-evoked activity of sensorimotor neurons in the swamp sparrow's brain that are known to be important for the learning, performance and perception of song. In freely behaving adult sparrows that sang songs with normal syntax, neurons were detected that exhibited precisely time-locked activity to each repetition of the syllable in a trill when presented at a natural rate. Those cells failed to faithfully follow syllables presented at an accelerated rate, however, and their failure to respond to consecutive syllables increased as a function of trill rate. This "flickering" auditory representation in animals performing normal syntax reveals a central constraint on the sensory processing of rapid trills. Furthermore, because these neurons are implicated in both song learning and perception, and because auditory flickering began to occur at accelerated trill rates previously associated with the emergence of broken song syntax, these sensory constraints may contribute to the emergence of broken syntax.

  10. Sensory Constraints on Birdsong Syntax: Neural Responses to Swamp Sparrow Songs with Accelerated Trill Rates

    PubMed Central

    Prather, JF; Peters, S; Mooney, R; Nowicki, S

    2013-01-01

    Both sensory and motor mechanisms can constrain behavioral performance. Sensory mechanisms may be especially important for constraining behaviors that depend on experience, such as learned birdsongs. Swamp sparrows learn to sing by imitating the song of a tutor, but sparrows fail to accurately imitate artificial tutor songs with abnormally accelerated trills, instead singing brief and rapid trills interrupted by silent gaps. This “broken syntax” has been proposed to arise from vocal-motor limitations. Here we consider whether sensory limitations exist that could also contribute to broken syntax. We tested this idea by recording auditory-evoked activity of sensorimotor neurons in the swamp sparrow’s brain that are known to be important for the learning, performance and perception of song. In freely behaving adult sparrows that sang songs with normal syntax, neurons were detected that exhibited precisely time-locked activity to each repetition of the syllable in a trill when presented at a natural rate. Those cells failed to faithfully follow syllables presented at an accelerated rate, however, and their failure to respond to consecutive syllables increased as a function of trill rate. This “flickering” auditory representation in animals performing normal syntax reveals a central constraint on the sensory processing of rapid trills. Furthermore, because these neurons are implicated in both song learning and perception, and because auditory flickering began to occur at accelerated trill rates previously associated with the emergence of broken song syntax, these sensory constraints may contribute to the emergence of broken syntax. PMID:23976787

  11. Recent acceleration in coastal cliff retreat rates on the south coast of Great Britain.

    PubMed

    Hurst, Martin D; Rood, Dylan H; Ellis, Michael A; Anderson, Robert S; Dornbusch, Uwe

    2016-11-22

    Rising sea levels and increased storminess are expected to accelerate the erosion of soft-cliff coastlines, threatening coastal infrastructure and livelihoods. To develop predictive models of future coastal change we need fundamentally to know how rapidly coasts have been eroding in the past, and to understand the driving mechanisms of coastal change. Direct observations of cliff retreat rarely extend beyond 150 y, during which humans have significantly modified the coastal system. Cliff retreat rates are unknown in prior centuries and millennia. In this study, we derived retreat rates of chalk cliffs on the south coast of Great Britain over millennial time scales by coupling high-precision cosmogenic radionuclide geochronology and rigorous numerical modeling. Measured (10)Be concentrations on rocky coastal platforms were compared with simulations of coastal evolution using a Monte Carlo approach to determine the most likely history of cliff retreat. The (10)Be concentrations are consistent with retreat rates of chalk cliffs that were relatively slow (2-6 cm⋅y(-1)) until a few hundred years ago. Historical observations reveal that retreat rates have subsequently accelerated by an order of magnitude (22-32 cm⋅y(-1)). We suggest that acceleration is the result of thinning of cliff-front beaches, exacerbated by regional storminess and anthropogenic modification of the coast.

  12. Recent acceleration in coastal cliff retreat rates on the south coast of Great Britain

    NASA Astrophysics Data System (ADS)

    Hurst, Martin D.; Rood, Dylan H.; Ellis, Michael A.; Anderson, Robert S.; Dornbusch, Uwe

    2016-11-01

    Rising sea levels and increased storminess are expected to accelerate the erosion of soft-cliff coastlines, threatening coastal infrastructure and livelihoods. To develop predictive models of future coastal change we need fundamentally to know how rapidly coasts have been eroding in the past, and to understand the driving mechanisms of coastal change. Direct observations of cliff retreat rarely extend beyond 150 y, during which humans have significantly modified the coastal system. Cliff retreat rates are unknown in prior centuries and millennia. In this study, we derived retreat rates of chalk cliffs on the south coast of Great Britain over millennial time scales by coupling high-precision cosmogenic radionuclide geochronology and rigorous numerical modeling. Measured 10Be concentrations on rocky coastal platforms were compared with simulations of coastal evolution using a Monte Carlo approach to determine the most likely history of cliff retreat. The 10Be concentrations are consistent with retreat rates of chalk cliffs that were relatively slow (2-6 cmṡy-1) until a few hundred years ago. Historical observations reveal that retreat rates have subsequently accelerated by an order of magnitude (22-32 cmṡy-1). We suggest that acceleration is the result of thinning of cliff-front beaches, exacerbated by regional storminess and anthropogenic modification of the coast.

  13. A comparison of constant acceleration swimming speeds when acceleration rates are different with critical swimming speeds in Chinese bream under two oxygen tensions.

    PubMed

    Wang, Jian-Wei; Cao, Zhen-Dong; Fu, Shi-Jian

    2016-10-01

    To investigate the effect of acceleration rates on the constant acceleration test speed (U cat) and to compare U cat with the critical swimming speed (U crit) in Chinese bream (Parabramis pekinensis), the U cat test at acceleration rates of 0.05, 0.1, 0.2, 0.4 and 0.8 cm s(-2) and the U crit test in juvenile fish at 20 °C in either normoxia (>90 % saturation oxygen tension) or hypoxia (30 % saturation) were compared. The lactate concentration ([lactate]) of white muscle, liver and plasma and the glycogen concentration ([glycogen]) of white muscle and liver were also measured to identify whether tissue substrate depletion or tissue lactate accumulation correlated with exhaustion. The U cat decreased with the acceleration rate, and there was no significant difference between U crit and U cat at lower acceleration rates. Hypoxia resulted in lower U cat and U crit, and the difference increased with decreased acceleration rates of the U cat test, possibly due to the increased contribution of aerobic components in U crit or U cat at low acceleration rates. Hypoxia elicited a significant decrease in muscle [glycogen] and an increase in muscle and liver [lactate] in resting fish. All post-exercise fish had similar muscle [lactate], suggesting that tissue lactate accumulation may correlate with exercise exhaustion. Unlike hypoxia, exercise induced an increase in muscle [lactate] and a significant increase in plasma [lactate], which were worthy of further investigation. The similar swimming speed and biochemical indicators after exercise in the U crit and U cat groups at low acceleration rates suggested that U cat can be an alternative for the more frequently adopted protocols in U crit in Chinese bream and possibly in other cyprinid fish species.

  14. The Role of Cracks in Accelerating the Rate of Landslide Movement

    NASA Astrophysics Data System (ADS)

    Weirich, F. H.; Blesius, L.

    2013-12-01

    The mechanisms responsible for deep seated landslides often involve the complex interplay of a number of factors that contribute to the initiation, accelerated rates of movement, and often catastrophic failures associated with these types of mass movement processes. One of the challenges associated with the study of such events is the determination of the trigger mechanism that tips the scale in favor of movement, accelerated movement, or catastrophic failure. Much research has been directed at the role of a number of factors such as: basic geology, failure zones, preferential slide planes,vegetative root strength, rainfall amounts, rates and basic infiltration dynamics that may contribute to movement or failure, or at times even serve as the primary forcing mechanism leading to failure or accelerated movement. However, the role of surface cracks in impacting the hydrologic balance of a hillslope and ultimately the stability of a hillside has received relatively little attention. In an effort to better understand the potential role of surface cracks in altering the hydrologic balance and ultimately the stability and rate of movement of deep seated slope failures, an evaluation of a relatively large scale landslide in Los Flores Canyon, Malibu, CA was undertaken. The Los Flores Canyon slide area encompasses an area in excess of 50 acres (+ 200,000 m2), with an overall slide volume in excess of 25 M cubic meters. Over the years, it has undergone wide and often relatively rapid variation in movement rates with toe movement rates ranging from under 0.3 m/yr up to rates exceeding 2.5 m/yr. Local rates on major portions of the slide surface have exceeded 25 m/yr at times. Combining basic geologic, rainfall, urban runoff, fire, and landslide movement data with a careful GIS based evaluation of the initiation and development of crack systems on the slide mass it was determined that in some instances, once the initial movement of the slide had begun, some of the subsequent

  15. Acceleration of ventricular rate by fibrillation associated with the Wolff-Parkinson-White syndrome.

    PubMed

    Sheinman, B D; Evans, T

    1982-10-09

    Amiodarone has proved to be a valuable drug in atrial fibrillation associated with the Wolff-Parkinson-White syndrome. When it was administered to a patient with this syndrome in atrial fibrillation, who had previously suffered an inferior myocardial infarction, the ventricular rate accelerated from 170 to 230 beats/minute.This unusual case emphasises the need for full electrophysiological assessment of patients with the Wolff-Parkinson-White syndrome for whom amiodarone treatment is being considered.

  16. Application of Rate Theory to Accelerated Durability Testing of Structural Adhesives

    DTIC Science & Technology

    1980-03-01

    comes too late to impact on material selection or design considerations. The analytical approach, coupled with an accelerated 10 testing program, is...estimated range and then evaluating the impact of each parameter on the failure rate and expected service life. The life-limiting components and the...interest of processing economy can be identified. This information can then be fed back into the system design process and the analyses repeated to

  17. Ambient dose and dose rate measurements in the vicinity of Elekta Precise accelerators for radiation therapy.

    PubMed

    Zutz, H; Hupe, O

    2014-12-01

    In radiation therapy, commercially available medical linear accelerators (LINACs) are used. At high primary beam energies in the 10-MeV range, the leakage dose of the accelerator head and the backscatter from the room walls, the air and the patient become more important. Therefore, radiation protection measurements of photon dose rates in the treatment room and in the maze are performed to quantify the radiation field. Since the radiation of the LINACs is usually pulsed with short radiation pulse durations in the microsecond range, there are problems with electronic dose (rate) meters commonly used in radiation protection. In this paper measurements with ionisation chambers are presented and electronic dosemeters are used for testing at selected positions. The measured time-averaged dose rate ranges from a few microsieverts per hour in the maze to some millisieverts per hour in the vicinity of the accelerator head and up to some sieverts per hour in the blanked primary beam and several hundred sieverts per hour in the direct primary beam.

  18. The lead-glass electromagnetic calorimeter for the SELEX experiment

    SciTech Connect

    M. Y. Balatz et al.

    2004-07-19

    A large-acceptance, highly segmented electromagnetic lead glass calorimeter for Experiment E781 (SELEX) at Fermi National Acceleration Laboratory was designed and built. This detector has been used to reconstruct photons and electrons with energies ranging from few GeV up to 500 GeV in the collisions of the 650 GeV {Sigma}{sup -} hyperons and {pi}{sup -} mesons with the target nucleons. The design, calibration and performance of the calorimeter are described. Energy resolution and position resolution are assessed using both calibration electron beams and {pi}{sup 0} mesons reconstructed in 650 GeV hadron-hadron interactions. The performance of the calorimeter in selecting resonant states that involve photons is demonstrated.

  19. The NA62 liquid Krypton calorimeter's new readout system

    NASA Astrophysics Data System (ADS)

    Ceccucci, A.; Fantechi, R.; Farthouat, P.; Lamanna, G.; Rouet, J.; Ryjov, V.; Venditti, S.

    2014-01-01

    The NA62 experiment [1] at CERN SPS (Super Proton Synchrotron) accelerator aims at studying Kaon decays with high precision. The high resolution Liquid Krypton (LKr) calorimeter, built for the NA48 [2] experiment, is a crucial part of the experiment photon-veto system; to cope with the new requirements, the back-end electronics of the LKr had to be completely renewed. Due to the huge number of the calorimeter readout channels ( ~ 14 K) and the maintenance requirement over 10 years of the experiment lifetime, the decision to sub-contract the development and production to industry was taken in 2011. This paper presents the primary test results of the Calorimeter REAdout Module (CREAM) [3] prototype delivered by the manufacturer in March 2013. All essential features, analog performance, data processing and readout, are covered.

  20. A merged quadrupole-calorimeter for CEPC

    NASA Astrophysics Data System (ADS)

    Talman, Richard; Hauptman, John

    2016-11-01

    The luminosity ℒ of colliding beams in a storage ring such as CEPC depends strongly on l∗, the half-length of the free space centered on the intersection point (IP). l∗ is also the length from the IP to the front edges of the two near-in quadrupoles that are focusing the counter-circulating beams to the IP spot. The detector length cannot, therefore, exceed 2l∗. Since ℒ increases strongly with decreasing l∗, there is incentive for reducing l∗; but this requires the detector to be shorter than desirable. This paper proposes a method for integrating these adjacent quadrupoles into the particle detector to retain (admittedly degraded) active particle detection of those forward going particles that would otherwise be obscured by the quadrupole. A gently conical quadrupole shape is more natural for merging the quadrupole into the particle detector than is the analytically exact cylindrical shape. This is true whether or not the calorimeter is integrated. It will be the task of accelerator physicists to determine the extent to which deviation from the pure quadrupole field compromises (or improves) accelerator performance. Superficially, both the presence of strongest gradient close to the IP and largest aperture farther from the IP seem to be advantageous. A tentative design for this merged, quadrupole-calorimeter is given.

  1. The Formalism for Energy Changing Rate of an Accelerated Atom Coupled with Electromagnetic Vacuum Fluctuations

    NASA Astrophysics Data System (ADS)

    Zhang, Anwei

    2016-09-01

    The structure of the rate of variation of the atomic energy for an arbitrary stationary motion of the atom in interaction with a quantum electromagnetic field is investigated. Our main purpose is to rewrite the formalism in Zhu et al. (Phys Rev D 73:107501, 2006) and to deduce the general expressions of the Einstein A coefficients of an atom on an arbitrary stationary trajectory. The total rate of change of the energy and Einstein coefficients of the atom near a plate with finite temperature or acceleration are also investigated.

  2. The Zeus calorimeter first level trigger

    SciTech Connect

    Smith, W.J.

    1989-04-01

    The design of the Zeus Detector Calorimeter Level Trigger is presented. The Zeus detector is being built for operation at HERA, a new storage ring that will provide collisions between 820 GeV protons and 30 GeV electrons in 1990. The calorimeter is made of depleted uranium plates and plastic scintillator read out by wavelength shifter bars into 12,864 photomultiplier tubes. These signals are combined into 974 trigger towers with separate electromagnetic and hadronic sums. The calorimeter first level trigger is pipelined with a decision provided 5 {mu}sec after each beam crossing, occurring every 96 nsec. The trigger determines the total energy, the total transverse energy, the missing energy, and the energy and number of isolated electrons and muons. It also provides information on the number and energy of clusters. The trigger rate needs to be held to 1 kHz against a rate of proton-beam gas interactions of approximately 500 kHz. The summed trigger tower pulseheights are digitized by flash ADC`s. The digital values are linearized, stored and used for sums and pattern tests.

  3. Simulations of a Thin Sampling Calorimeter with GEANT/FLUKA

    NASA Technical Reports Server (NTRS)

    Lee, Jeongin; Watts, John; Howell, Leonard; Rose, M. Franklin (Technical Monitor)

    2000-01-01

    The Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS) will investigate the origin, composition and acceleration mechanism of cosmic rays by measuring the elemental composition of the cosmic rays up to 10(exp 15) eV. These measurements will be made with a thin ionization calorimeter and a transition radiation detector. This paper reports studies of a thin sampling calorimeter concept for the ACCESS thin ionization calorimeter. For the past year, a Monte Carlo simulation study of a Thin Sampling Calorimeter (TSC) design has been conducted to predict the detector performance and to design the system for achieving the ACCESS scientific objectives. Simulation results show that the detector energy resolution function resembles a Gaussian distribution and the energy resolution of TSC is about 40%. In addition, simulations of the detector's response to an assumed broken power law cosmic ray spectra in the region where the 'knee' of the cosmic ray spectrum occurs have been conducted and clearly show that a thin sampling calorimeter can provide sufficiently accurate estimates of the spectral parameters to meet the science requirements of ACCESS. n

  4. The CDF miniplug calorimeters

    SciTech Connect

    Lami, Stefano

    2002-06-28

    Two MiniPlug calorimeters, designed to measure the energy and lateral position of particles in the (forward) pseudorapidity region of 3.6 < |{nu}| < 5.2 of the CDF detector, have been recently installed as part of the Run II CDF upgrade at the Tevatron {bar p}p collider. They consist of lead/liquid scintillator read out by wavelength shifting fibers arranged in a pixel-type towerless geometry suitable for ''calorimetric tracking''. The design concept, the prototype performance and the final design of the MiniPlugs are here described. A recent cosmic ray test resulted in a light yield of approximately 100 pe/MIP, which exceeds our design requirements.

  5. Double beta decay: Calorimeters

    NASA Astrophysics Data System (ADS)

    Brofferio, Chiara

    2008-11-01

    Calorimeters or, with a more specific definition, low temperature detectors, have been used by now for more than 15 years in Double Beta Decay (DBD) searches, with excellent results: they compete with Ge diodes for the rank of detectors with the highest sensitivity to the effective neutrino mass, which is defined as a linear combination of the neutrino mass eigenvalues. After a brief introduction to the argument, with some notes on DBD and on bolometers, an update on the now closed experiment CUORICINO and on its successor, CUORE, is given. The fundamental role of background is then revealed and commented, introducing in this way the importance of the specific experiment now under construction, CUORE-0, that will precede CUORE to help optimizing the struggle against surface background. The possible future of this technique is then commented, quoting important R&D studies that are going on, for active shielding bolometers and for scintillating bolometers coupled with light detecting bolometers.

  6. Error-Rate Estimation Based on Multi-Signal Flow Graph Model and Accelerated Radiation Tests

    PubMed Central

    Wang, Yueke; Xing, Kefei; Deng, Wei; Zhang, Zelong

    2016-01-01

    A method of evaluating the single-event effect soft-error vulnerability of space instruments before launched has been an active research topic in recent years. In this paper, a multi-signal flow graph model is introduced to analyze the fault diagnosis and meantime to failure (MTTF) for space instruments. A model for the system functional error rate (SFER) is proposed. In addition, an experimental method and accelerated radiation testing system for a signal processing platform based on the field programmable gate array (FPGA) is presented. Based on experimental results of different ions (O, Si, Cl, Ti) under the HI-13 Tandem Accelerator, the SFER of the signal processing platform is approximately 10−3(error/particle/cm2), while the MTTF is approximately 110.7 h. PMID:27583533

  7. The origin of modern frogs (Neobatrachia) was accompanied by acceleration in mitochondrial and nuclear substitution rates

    PubMed Central

    2012-01-01

    Background Understanding the causes underlying heterogeneity of molecular evolutionary rates among lineages is a long-standing and central question in evolutionary biology. Although several earlier studies showed that modern frogs (Neobatrachia) experienced an acceleration of mitochondrial gene substitution rates compared to non-neobatrachian relatives, no further characterization of this phenomenon was attempted. To gain new insights on this topic, we sequenced the complete mitochondrial genomes and nine nuclear loci of one pelobatoid (Pelodytes punctatus) and five neobatrachians, Heleophryne regis (Heleophrynidae), Lechriodus melanopyga (Limnodynastidae), Calyptocephalella gayi (Calyptocephalellidae), Telmatobius bolivianus (Ceratophryidae), and Sooglossus thomasseti (Sooglossidae). These represent major clades not included in previous mitogenomic analyses, and most of them are remarkably species-poor compared to other neobatrachians. Results We reconstructed a fully resolved and robust phylogeny of extant frogs based on the new mitochondrial and nuclear sequence data, and dated major cladogenetic events. The reconstructed tree recovered Heleophryne as sister group to all other neobatrachians, the Australasian Lechriodus and the South American Calyptocephalella formed a clade that was the sister group to Nobleobatrachia, and the Seychellois Sooglossus was recovered as the sister group of Ranoides. We used relative-rate tests and direct comparison of branch lengths from mitochondrial and nuclear-based trees to demonstrate that both mitochondrial and nuclear evolutionary rates are significantly higher in all neobatrachians compared to their non-neobatrachian relatives, and that such rate acceleration started at the origin of Neobatrachia. Conclusions Through the analysis of the selection coefficient (ω) in different branches of the tree, we found compelling evidence of relaxation of purifying selection in neobatrachians, which could (at least in part) explain the

  8. High density fluoride glass calorimeter

    NASA Astrophysics Data System (ADS)

    Xie, Q.; Scheltzbaum, J.; Akgun, U.

    2014-04-01

    The unprecedented radiation levels in current Large Hadron Collider runs, and plans to even increase the luminosity creates a need for new detector technologies to be investigated. Quartz plates to replace the plastic scintillators in current LHC calorimeters have been proposed in recent reports. Quartz based Cherenkov calorimeters can solve the radiation damage problem, however light production and transfer have proven to be challenging. This report summarizes the results from a computational study on the performance of a high-density glass calorimeter. High-density, scintillating, fluoride glass, CHG3, was used as the active material. This glass has been developed specifically for hadron collider experiments, and is known for fast response time, in addition to high light yield. Here, the details of a Geant4 model for a sampling calorimeter prototype with 20 layers, and its hadronic as well as electromagnetic performances are reported.

  9. Accelerated Testing Methodology in Constant Stress-Rate Testing for Advanced Structural Ceramics: A Preloading Technique

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.; Huebert, Dean; Bartlett, Allen; Choi, Han-Ho

    2001-01-01

    Preloading technique was used as a means of an accelerated testing methodology in constant stress-rate ('dynamic fatigue') testing for two different brittle materials. The theory developed previously for fatigue strength as a function of preload was further verified through extensive constant stress-rate testing for glass-ceramic and CRT glass in room temperature distilled water. The preloading technique was also used in this study to identify the prevailing failure mechanisms at elevated temperatures, particularly at lower test rate in which a series of mechanisms would be associated simultaneously with material failure, resulting in significant strength increase or decrease. Two different advanced ceramics including SiC whisker-reinforced composite silicon nitride and 96 wt% alumina were used at elevated temperatures. It was found that the preloading technique can be used as an additional tool to pinpoint the dominant failure mechanism that is associated with such a phenomenon of considerable strength increase or decrease.

  10. Accelerated Testing Methodology in Constant Stress-Rate Testing for Advanced Structural Ceramics: A Preloading Technique

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.; Huebert, Dean; Bartlett, Allen; Choi, Han-Ho

    2001-01-01

    Preloading technique was used as a means of an accelerated testing methodology in constant stress-rate (dynamic fatigue) testing for two different brittle materials. The theory developed previously for fatigue strength as a function of preload was further verified through extensive constant stress-rate testing for glass-ceramic and CRT glass in room temperature distilled water. The preloading technique was also used in this study to identify the prevailing failure mechanisms at elevated temperatures, particularly at lower test rates in which a series of mechanisms would be associated simultaneously with material failure, resulting in significant strength increase or decrease. Two different advanced ceramics including SiC whisker-reinforced composite silicon nitride and 96 wt% alumina were used at elevated temperatures. It was found that the preloading technique can be used as an additional tool to pinpoint the dominant failure mechanism that is associated with such a phenomenon of considerable strength increase or decrease.

  11. Clinical evaluation of peak endocardial acceleration as a sensor for rate responsive pacing.

    PubMed

    Greco, Enrico Maria; Ferrario, Marco; Romano, Salvatore

    2003-04-01

    An innovative control parameter for rate responsive (RR) pacing that uses a sensor to measure mechanical vibrations generated by the myocardium during the isovolumetric contraction phase (peak endocardial acceleration [PEA]), has been devised by SORIN Biomedica (BEST Living System). To assess the physiological sensitivity of the pacemaker sensor along with reliability of the algorithm to supply appropriate pacing rates three different relationships were examined (linear regression analysis): (1) recorded deltaPEA exercise steps against the calculated energy cost of exercise (MET), (2) exercise pacing rates against predicted values, and (3) deltaPEA against exercise pacing rates. Fifteen patients (mean age 68 +/- 12 years) in NYHA Class I-II, implanted with the BEST Living System (Living 1 DDDR pacemaker) for advanced AVB and/or SSS, underwent one of the following maximal exercise stress protocols: bicycle (25 W, 2-minute steps) or Bruce or Chronotropic Assessment Exercise Protocol (CAEP). Pacing rates for each step were matched against those predicted by a reliable and tested custom software called Pacing Rate Profile Software (PRPS). The PRPS is based on the oxygen pulse reserve (OPR) method (OPR = VO2 reserve divided by heart rate reserve), American College of Sports Medicine (ACSM) formulas for calculating workload/metabolic requirements, and data derived from the Weber functional classes. On the basis of certain patient, data the PRPS then supplies appropriate metabolic pacing rate profiles. In all 15 patients linear regression analysis of deltaPEA against MET, as evaluated during the exercise protocol steps, showed a high correlation (r = 0.97). Likewise, a high correlation was also obtained between PRPS predicted heart rates and exercise pacing rates (r = 0.96) and PEA against exercise pacing rates (r = 0.96). The results of this study show that, through PEA dynamic monitoring, the SORIN Best Living System produces physiological pacing rates that are

  12. The effects of acceleration rate on vehicle exhaust emissions and fuel economy. Technical report

    SciTech Connect

    Landman, L.C.

    1982-08-01

    This report summarizes a test program which was designed to explore the impact on exhaust emissions and fuel economy of coupling the dynamometer rollers (front and rear) and of using acceleration rates higher than those used on the Federal Test Procedure (FTP). A total of six vehicles were tested in this program. All five gasoline-fueled exhibited increases in hydrocarbons (HC) and carbon monoxide (CO) emissions on the Federal Test Procedure (FTP) driving cycle when the dynamometer rollers were coupled. The other results are strongly vehicle dependent.

  13. Beam test results of a high-granularity tile/fiber electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Ono, H.; Miyata, H.; Iba, S.; Nakajima, N.; Sanchez, A. L. C.; Fujii, Y.; Itoh, S.; Kajino, F.; Kanzaki, J.; Kawagoe, K.; Kim, S.; Kishimoto, S.; Matsumoto, T.; Matsunaga, H.; Nagano, A.; Nakamura, R.; Takeshita, T.; Tamura, Y.; Yamauchi, S.

    2009-03-01

    A prototype sampling electromagnetic calorimeter (17.1 radiation lengths) for future linear collider experiments was built, using 4 cm×4 cm×1 mm plastic scintillator tiles and 4 mm-thick lead absorber. Wavelength-shifting fibers were used to guide the scintillation light into multi-anode photo-multiplier tubes. The calorimeter was tested at the beam test facility of the High Energy Accelerator Research Organization (KEK) in 2004. In this article we present our beam test results for the tile/fiber calorimeter focusing on the linearity in energy response, the energy resolution, position resolution and uniformity across the tile front face.

  14. Thermal study of a non adiabatic differential calorimeter used for nuclear heating measurements inside an experimental channel of the Jules Horowitz Reactor

    NASA Astrophysics Data System (ADS)

    Reynard-Carette, C.; Lyoussi, A.; Brun, J.; Muraglia, M.; Carette, M.; Janulyte, A.; Zerega, Y.; André, J.; Bignan, G.; Chauvin, J.-P.; Fourmentel, D.; Gonnier, C.; Guimbal, P.; Malo, J.-Y.; Villard, J.-F.

    2012-11-01

    New online in-pile measurement methods are crucial during irradiations in Material Testing Reactors (MTR) for a better understanding of accelerated material ageing and nuclear fuel behaviour. In particular, instrumentation for measurements of one relevant parameter: nuclear heat deposition rate, called nuclear heating, has to be improved. The knowledge of this quantity is a great interest for various safety, scientist and end-user requirements (design of specific irradiation devices and associated cooling systems with imposed conditions). This paper focuses on thermal experimental and numerical studies carried out under non irradiation conditions on an in-pile calorimeter dedicated to nuclear heating quantification inside a new experimental device which will be dedicated to the experimental condition mapping (neutron and photon fluxes and nuclear heating) inside the JHR experimental channels. Experimental results concerning the calorimeter response during its electrical calibration (<3W) under laminar forced convection conditions show that its sensitivity does not depend on the cooling flow. Temperature and heat flux density measurements lead to the conclusion of a good directional conductive heat flow design (increased with a higher Reynolds number). A parametric numerical stationary study highlights a sensor sensitivity increasing. At last, the usual calorimeter design is compared to a single calorimeter which gives promising results (miniaturization, higher sensitivity).

  15. Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment

    NASA Technical Reports Server (NTRS)

    Wefel, John P.; Guzik, T. Gregory

    2001-01-01

    During grant NAG5-5064, Louisiana State University (LSU) led the ATIC team in the development, construction, testing, accelerator validation, pre-deployment integration and flight operations of the Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment. This involved interfacing among the ATIC collaborators (UMD, NRL/MSFC, SU, MSU, WI, SNU) to develop a new balloon payload based upon a fully active calorimeter, a carbon target, a scintillator strip hodoscope and a pixilated silicon solid state detector for a detailed investigation of the very high energy cosmic rays to energies beyond 10(exp 14) eV/nucleus. It is in this very high energy region that theory predicts changes in composition and energy spectra related to the Supernova Remnant Acceleration model for cosmic rays below the "knee" in the all-particle spectrum. This report provides a documentation list, details the anticipated ATIC science return, describes the particle detection principles on which the experiment is based, summarizes the simulation results for the system, describes the validation work at the CERN SPS accelerator and details the balloon flight configuration. The ATIC experiment had a very successful LDB flight from McMurdo, Antarctica in 12/00 - 1/01. The instrument performed well for the entire 15 days. Preliminary data analysis shows acceptable charge resolution and an all-particle power law energy deposition distribution not inconsistent with previous measurements. Detailed analysis is underway and will result in new data on the cosmic ray charge and energy spectra in the GeV - TeV energy range. ATIC is currently being refurbished in anticipation of another LDB flight in the 2002-03 period.

  16. Noise dependence with pile-up in the ATLAS Tile Calorimeter. Pile-up noise studies in the ATLAS TileCal calorimeter

    SciTech Connect

    Araque, J.P.

    2015-07-01

    The Tile Calorimeter, TileCal, is the central hadronic calorimeter of the ATLAS experiment, positioned between the electromagnetic calorimeter and the muon chambers. It comprises alternating layers of steel (as absorber material) and plastic (as active material), known as tiles. Between 2009 and 2012, the LHC has performed better than expected producing proton-proton collisions at a very high rate. These conditions are really challenging when dealing with the energy measurements in the calorimeter since not only the energy from an interesting event will be measured but a component coming from other collisions, which are difficult to distinguish from the interesting one, will also be present. This component is referred to as pile-up noise. Studies carried out to better understand how pile-up affects calorimeter noise under different circumstances are described. (author)

  17. Reaction Rate Acceleration and Tg Depression of Polycyanurate Under Nanopore Confinement

    NASA Astrophysics Data System (ADS)

    Lopez, Evelyn; Simon, Sindee L.

    2015-03-01

    Material properties such as Tg and the reaction kinetics are known to deviate from the bulk when subjected to nano-sized confinement. Previous work from our laboratory on the trimerization of cyanate esters found that the reaction kinetics were faster for a monofunctional reactant compared to a difunctional monomer, whereas the Tg depression was greater for the crosslinked product of the latter compared to the low molecular weight trimer of the former. The origin of the changes in nanoconfined reaction rates differs from those that govern changes in the Tg. The research objective is to further explore the effect that confinement has on reaction kinetics and Tg using a mixture consisting of mono- and di- cyanate ester monomers. The product is an uncrosslinked polycyanurate with Mn = 5240 g/mol and PDI = 1.78. The confinement mediums are controlled pore glasses with diameters ranging from 8.1 to 111.1 nm. The nanopore-confined material was synthesized in-situ and the reaction kinetics are followed by DSC; after the reaction, the Tg values of the nanoconfined polymer where also measured by DSC. An acceleration factor of 13 and a Tg depression of 38 °C are observed for the material confined in the smallest 8.1 nm-diameter pores. The Tg depression is between those of the trimer and network previously studied, while the acceleration of the reaction rate is lower. Our results are consistent with the reaction acceleration arising from packing effects at the pore wall and the Tg depression arising from intrinsic size effects.

  18. Verification of Electromagnetic Calorimeter Concept for the HADES spectrometer

    NASA Astrophysics Data System (ADS)

    Svoboda, O.; Blume, C.; Czyžycki, W.; Epple, E.; Fabbietti, L.; Galatyuk, T.; Golubeva, M.; Guber, F.; Hlaváč, S.; Ivashkin, A.; Kajetanowic, M.; Kardan, B.; Koenig, W.; Kugler, A.; Lapidus, K.; Linev, S.; Lisowski, E.; Ott, P.; Otte, P.; Petukhov; Pietraszko, J.; Reshetin, A.; Rodríguez-Ramos, P.; Rost, A.; Salabura, P.; Skott, P.; Sobolev, Y. G.; Steffen, O.; Thomas, A.; Tlustý, P.; Traxler, M.

    2015-04-01

    The HADES spectrometer currently operating on the beam of SIS18 accelerator in GSI will be moved to a new position in the CBM cave of the future FAIR complex. Electromagnetic calorimeter (ECAL) will enable the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions at the energy range of 2-10 A GeVon the beam of the new accelerator SIS100. Calorimeter will be based on 978 massive lead glass modules read out by photomultipliers and a novel front-end electronics. Secondary gamma beam with energies ranging from 81 MeV up to 1399 MeV from MAMI-C Mainz facility was used to verify selected technical solutions. Relative energy resolution was measured using modules with three different types of photomultipliers. Two types of developed front-end electronics as well as energy leakage between neighbouring modules under parallel and declined gamma beams were studied in detail.

  19. Mortality rate acceleration and post-reproductive lifespan in matrilineal whale species.

    PubMed

    Foote, Andrew D

    2008-04-23

    The strength of selection to increase the span of a life stage is dependent upon individuals at that stage being able to contribute towards individual fitness and the probability of their surviving to that stage. Complete reproductive cessation and a long post-reproductive female lifespan as found in humans are also found in killer whale (Orcinus orca) and short-finned pilot whale (Globicephala macrorhynchus), but not in the long-finned pilot whale (Globicephala melaena). Each species forms kin-based, stable matrilineal groups and exhibits kin-directed behaviours that could increase inclusive fitness. Here, the initial mortality rate and mortality rate-doubling time of females of these three closely related whale species are compared. The initial mortality rate shows little variation among pilot whale species; however mortality rate accelerates almost twice as fast in the long-finned pilot whale as it does in killer whale and short-finned pilot whale. Selection for a long post-reproductive female lifespan in matrilineal whales may therefore be determined by the proportion of females surviving past the point of reproductive cessation.

  20. The segmentation of hadron calorimeters

    NASA Astrophysics Data System (ADS)

    Chen, He Sheng

    1987-05-01

    Optimization of the segmentation of large hadron calorimeters is important in order to obtain good resolution for jet physics at minimum construction cost for the next generation of high energy experiments. The principles of the segmentation of hadron calorimeters are discussed. As an example, the Monte Carlo optimization of the segmentation of the L3 hadron calorimeter barrel at CERN is described. Comparisons of results for the reconstructed jet shapes show that the optimum number ADC channels is about 20K for the readout of 450K wires of the proportional chambers. The matching between the sandwiched φ towers and Z towers is the dominant factor for angular resolution. Based on these Monte Carlo simulations, an optimized tower structure is obtained.

  1. Canine fetal heart rate: do accelerations or decelerations predict the parturition day in bitches?

    PubMed

    Gil, E M U; Garcia, D A A; Giannico, A T; Froes, T R

    2014-10-15

    Ultrasonography is a safe and efficient technique for monitoring fetal development and viability. One of the most important and widely used parameters to verify fetal viability is the fetal heart rate (HR). In human medicine, the fetal HR normally oscillates during labor in transient accelerations and decelerations associated with uterine contractions. The present study investigated whether these variations also occur in canine fetuses and its relationship to parturition. A cohort study was conducted in 15 pregnant bitches undergoing two-dimensional high-resolution ultrasonographic examination during the 8th and 9th week of gestation. Fetal HR was assessed in M-mode for 5 minutes in each fetus in all bitches. In addition, the bitches were monitored for clinical signs of imminent parturition. Associations between the HR, antepartum time, and delivery characteristics were evaluated with a Poisson regression model. Fetal HR acceleration and deceleration occurred in canine fetuses and predicted the optimal time of parturition. These findings can help veterinarians and sonographers better understand this phenomenon in canine fetuses.

  2. Precision Timing Calorimeter for High Energy Physics

    DOE PAGES

    Anderson, Dustin; Apresyan, Artur; Bornheim, Adolf; ...

    2016-04-01

    Here, we present studies on the performance and characterization of the time resolution of LYSO-based calorimeters. Results for an LYSO sampling calorimeter and an LYSO-tungsten Shashlik calorimeter are presented. We also demonstrate that a time resolution of 30 ps is achievable for the LYSO sampling calorimeter. Timing calorimetry is described as a tool for mitigating the effects due to the large number of simultaneous interactions in the high luminosity environment foreseen for the Large Hadron Collider.

  3. Development of shashlik electromagnetic calorimeter prototype for SoLID

    NASA Astrophysics Data System (ADS)

    Shen, C.; Wang, Y.; Xiao, D.; Han, D.; Zou, Z.; Li, Y.; Zheng, X.; Chen, J.

    2017-03-01

    A shashlik electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for Solenoidal large Intensity Device (SoLID) to measure the energy deposition of electrons and hadrons, and to provide particle identification after the energy of the accelerator was upgraded to 12 GeV. Tsinghua University is the member of Hall A collaboration in charge of development and production of the large shashlik electromagnetic calorimeter of SoLID. One module of that calorimeter is composed by 194 layers. Each layer consists of a 1.5 mm thick plastic scintillator put on top of a 0.5 mm thick lead plate. Scintillation light is read out by wave-length shifter fibers penetrating through the calorimeter modules longitudinally along the direction of flight of the impact particle. This paper describes the design and construction of that module, as well as a few optimization studies meant to improve its performance. A detailed Geant4 simulation also shows that an energy resolution of 5%/√ E (GeV) and a good containment for electromagnetic showers can be achieved, as well as some basic electron identification. A prototype of that module will be tested soon with an electron beam at JLab.

  4. Electromagnetic calorimeter for the HADES@FAIR experiment

    NASA Astrophysics Data System (ADS)

    Svoboda, O.; Blume, C.; Czyžycki, W.; Epple, E.; Fabbietti, L.; Galatyuk, T.; Golubeva, M.; Guber, F.; Hlaváč, S.; Ivashkin, A.; Kajetanowic, M.; Kardan, B.; Koenig, W.; Kugler, A.; Lapidus, K.; Lisowski, E.; Pietraszko, J.; Reshetin, A.; Rost, A.; Salabura, P.; Sobolev, Y. G.; Tlusty, P.; Traxler, M.

    2014-05-01

    An electromagnetic calorimeter (ECAL) is being developed to complement the dilepton spectrometer HADES currently operating on the beam of the SIS18 heavy-ion synchrotron at GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany. The ECAL will allow the HADES@FAIR experiment to measure data on neutral meson production in heavy ion collisions in the energy range of 2-10 AGeV with the beam of the future accelerator SIS100@FAIR. The calorimeter will also improve the electron-hadron separation of the spectrometer, and will be used for the detection of photons from strange resonances in elementary and heavy ion reactions as well. The calorimeter will consist of 978 modules divided into 6 sectors, and it will cover forward angles of 16° < Θ < 45° and almost full azimuthal angle. Each module consists of a lead glass Cherenkov counter, photomultiplier, HV divider and an optical fiber. A dedicated LED based system being developed to monitor the stability of the calorimeter is discussed. Various prototypes of front-end electronics are presented and the achieved energy and time resolution determined using pulses from a pulse generator and a real detector signal induced by LED pulses and cosmic muons is shown as well.

  5. Computational method to estimate Single Event Upset rates in an accelerator environment

    NASA Astrophysics Data System (ADS)

    Huhtinen, M.; Faccio, F.

    2000-08-01

    We present a new method to estimate Single Event Upsets (SEU) in a hadron accelerator environment, which is characterized by a complicated radiation spectrum. Our method is based on first principles, i.e. an explicit generation and transport of nuclear fragments and detailed accounting for energy loss by ionization. However, instead of simulating also the behaviour of the circuit, we use a Weibull fit to experimental heavy-ion SEU data in order to quantify the SEU sensitivity of the circuit. Thus, in principle, we do not need to know details about the circuit and our method is almost free of adjustable parameters - we only need a reasonable guess for the Sensitive Volume (SV) size. We show by a comparison with experimental data that our method predicts the SEU cross sections for protons rather accurately. We then indicate with an example how our method could be applied to predict SEU rates at the forthcoming LHC experiments.

  6. Rate of energy gain and maximum energy in diffusive shock acceleration. [astrophysical implications

    NASA Technical Reports Server (NTRS)

    Jokipii, J. R.

    1987-01-01

    The problem of diffusive shock acceleration of fast charged particles is reexamined with emphasis on the rate of energy gain, and the maximum energy which can be attained in a given circumstance. The direction of the average magnetic field at the shock is shown to have a large effect. If the perpendicular diffusion coefficient is much smaller than the parallel coefficient, particles can gain much more energy if the shock is quasi-perpendicular than if it is quasi-parallel. The maximum energy attainable can be substantially higher (by a factor of 100 or more) than previous discussions would predict, in cases where the shock is quasi-perpendicular. The energy gain increases as kappa-perpendicular decreases. The principal limitation comes from the requirement that diffusion be a valid approximation to the particle motion, and that the particle be able to diffuse fast enough to encounter the shock many times.

  7. GEANT SIMULATIONS OF PRESHOWER CALORIMETER FOR CLAS12 UPGRADE OF THE FORWARD ELECTROMAGNETIC CALORIMETER

    SciTech Connect

    Whitlow, K.; Stepanyan, S.

    2007-01-01

    Hall B at the Thomas Jefferson National Accelerator Facility uses the CEBAF (Continuous Electron Beam Accelerator Facility) Large Acceptance Spectrometer (CLAS) to study the structure of the nucleon. An upgrade from a 6 GeV beam to a 12GeV beam is currently planned. With the beam energy upgrade, more high-energy pions will be created from the interaction of the beam and the target. Above 6GeV, the angle between the two-decay photons of high-energy pions becomes too small for the current electromagnetic calorimeter (EC) of CLAS to differentiate between two photon clusters and single photon events. Thus, a preshower calorimeter will be added in front of the EC to enable fi ner granularity and ensure better cluster separation for all CLAS experiments at higher energies. In order to optimize cost without compromising the calorimeter’s performance, three versions of the preshower, varying in number of scintillator and lead layers, were compared by their resolution and effi ciency. Using GSIM, a GEANT detector simulation program for CLAS, the passage of neutral pions and single photons through CLAS and the new preshower calorimeter (CLAS12 EC) was studied. The resolution of the CLAS12 EC was calculated from the Gaussian fi t of the sampling fraction, the energy CLAS12 EC detected over the Monte Carlo simulated energy. The single photon detection effi ciency was determined from the energy and position of the photon hits. The fractional energy resolution measured was ΔE/E = 0.0972 in the fi ve-module version, 0.111 in the four-module version, and 0.149 in the three-module version. Both the fi ve- and four-module versions had 99% single photon detection effi ciency above 0.5GeV while the 3 module version had 99% effi ciency above 1.5GeV. Based on these results, the suggested preshower confi guration is the four-module version containing twelve layers of scintillator and fi fteen layers of lead. This version provides a reasonable balance of resolution, effi ciency, and

  8. Computer-interfaced low-temperature, high-pressure flow calorimeter

    NASA Astrophysics Data System (ADS)

    Gopal, P.; Zollweg, J. A.; Streett, W. B.

    1989-08-01

    A flow calorimeter suitable for the measurement of heats-of-mixing of liquefied gas binaries is described. The calorimeter may be operated at temperatures between 77 and 300 K and at pressures up to 15 MPa. Endothermic energy effects are measured with a precision of (1.5 J/mol±1.2% HM ). The apparatus incorporates flow meters that measure mass flow rates directly. A computer data-acquisition system facilitates rapid measurements, a single heat-of-mixing measurement requiring less than 20 min. The calorimeter was tested by measuring the heat-of-mixing for the nitrogen-argon system. The calorimeter is an improvement on previous low-temperature flow calorimeters in both accuracy and speed of measurement.

  9. COE1 Calorimeter Operations Manual

    SciTech Connect

    Santi, Peter Angelo

    2015-12-15

    The purpose of this manual is to describe the operations of the COE1 calorimeter which is used to measure the thermal power generated by the radioactive decay of plutonium-bearing materials for the purposes of assaying the amount of plutonium within the material.

  10. LHCb calorimeters high voltage system

    NASA Astrophysics Data System (ADS)

    Gilitsky, Yu.; Golutvin, A.; Konoplyannikov, A.; Lefrancois, J.; Perret, P.; Schopper, A.; Soldatov, M.; Yakimchuk, V.

    2007-02-01

    The calorimeter system in LHCb aims to identify electrons, photons and hadrons. All calorimeters are equipped with Hamamatsu photo tubes as devices for light to signal conversion. Eight thousand R7899-20 tubes are used for electromagnetic and hadronic calorimeters and two hundred 64 channels multi-anode R7600-00-M64 for Scintillator-Pad/Preshower detectors. The calorimeter high voltage (HV) system is based on a Cockroft Walton (CW) voltage converter and a control board connected to the Experiment Control System (ECS) by serial bus. The base of each photomultiplier tube (PMT) is built with a high voltage converter and constructed on an individual printed circuit board, using compact surface mount components. The base is attached directly to the PMT. There are no HV cables in the system. A Field Programmable Gate Array (FPGA) is used on the control board as an interface between the ECS and the 200 control channels. The FPGA includes also additional functionalities allowing automated monitoring and ramp up of the high voltage values. This paper describes the HV system architecture, some technical details of the electronics implementation and summarizes the system performance. This safe and low power consumption HV electronic system for the photomultiplier tubes can be used for various biomedical apparatus too.

  11. Barrel calorimeter of the CMD-3 detector

    SciTech Connect

    Shebalin, V. E. Anisenkov, A. V.; Aulchenko, V. M.; Bashtovoy, N. S.; Epifanov, D. A.; Epshteyn, L. B.; Grebenuk, A. A.; Ignatov, F. V.; Erofeev, A. L.; Kovalenko, O. A.; Kozyrev, A. N.; Kuzmin, A. S.; Logashenko, I. B.; Mikhailov, K. Yu.; Razuvaev, G. P.; Ruban, A. A.; Shwartz, B. A.; Talyshev, A. A.; Titov, V. M.; Yudin, Yu. V.

    2015-12-15

    The structure of the barrel calorimeter of the CMD-3 detector is presented in this work. The procedure of energy calibration of the calorimeter and the method of photon energy restoration are described. The distinctive feature of this barrel calorimeter is its combined structure; it is composed of two coaxial subsystems: a liquid xenon calorimeter and a crystalline CsI calorimeter. The calorimeter spatial resolution of the photon conversion point is about 2 mm, which corresponds to an angular resolution of ∼6 mrad. The energy resolution of the calorimeter is about 8% for photons with energy of 200 MeV and 4% for photons with energy of 1 GeV.

  12. Development of Metallic Magnetic Calorimeters for Nuclear Safeguards Applications

    SciTech Connect

    Bates, Cameron Russell

    2015-03-11

    Many nuclear safeguards applications could benefit from high-resolution gamma-ray spectroscopy achievable with metallic magnetic calorimeters. This dissertation covers the development of a system for these applications based on gamma-ray detectors developed at the University of Heidelberg. It demonstrates new calorimeters of this type, which achieved an energy resolution of 45.5 eV full-width at half-maximum at 59.54 keV, roughly ten times better than current state of the art high purity germanium detectors. This is the best energy resolution achieved with a gamma-ray metallic magnetic calorimeter at this energy to date. In addition to demonstrating a new benchmark in energy resolution, an experimental system for measuring samples with metallic magnetic calorimeters was constructed at Lawrence Livermore National Laboratory. This system achieved an energy resolution of 91.3 eV full-width at half-maximum at 59.54 keV under optimal conditions. Using this system it was possible to characterize the linearity of the response, the count-rate limitations, and the energy resolution as a function of temperature of the new calorimeter. With this characterization it was determined that it would be feasible to measure 242Pu in a mixed isotope plutonium sample. A measurement of a mixed isotope plutonium sample was performed over the course of 12 days with a single two-pixel metallic magnetic calorimeter. The relative concentration of 242Pu in comparison to other plutonium isotopes was determined by direct measurement to less than half a percent accuracy. This is comparable with the accuracy of the best-case scenario using traditional indirect methods. The ability to directly measure the relative concentration of 242Pu in a sample could enable more accurate accounting and detection of indications of undeclared activities in nuclear safeguards, a better constraint on source material in forensic samples containing plutonium, and improvements in verification in a future plutonium

  13. Effect of initial acceleration on the development of the flow field of an airfoil pitching at constant rate

    NASA Technical Reports Server (NTRS)

    Koochesfahani, M. M.; Smiljanovski, V.; Brown, T. A.

    1992-01-01

    We present results from a series of experiments where an airfoil is pitched at constant rate from 0 to 60 degrees angle of attack. It is well documented that the dynamic stall behavior of such an airfoil strongly depends on the nondimensional pitch rate K = dot-alpha C/(2U(sub infinity)), where C is the chord, dot-alpha the constant pitch rate, and U(sub infinity) the free stream speed. In reality, the actual motion of the airfoil deviates from the ideal ramp due to the finite acceleration and deceleration periods imposed by the damping of drive system and response characteristics of the airfoil. It is possible that the pitch rate alone may not suffice in describing the flow and that the details of the motion trajectory before achieving a desired constant pitch rate may also affect the processes involved in the dynamic stall phenomenon. The effects of acceleration and deceleration periods are investigated by systematically varing the acceleration magnitude and its duration through the initial acceleration phase to constant pitch rate. The magnitude and duration of deceleration needed to bring the airfoil motion to rest is similarly controlled.

  14. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'

    NASA Astrophysics Data System (ADS)

    Salter, Bill J.; Sarkar, Vikren; Wang, Brian; Shukla, Himanshu; Szegedi, Martin; Rassiah-Szegedi, Prema

    2011-04-01

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min-1) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  15. Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'.

    PubMed

    Salter, Bill J; Sarkar, Vikren; Wang, Brian; Shukla, Himanshu; Szegedi, Martin; Rassiah-Szegedi, Prema

    2011-04-07

    Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units per minute (MU min(-1)) high dose rate bursts of dose are facilitated by a flattening-filter-free treatment beam on a Siemens Artiste (Oncology Care Systems, Siemens Medical Solutions, Concord, CA, USA) digital linear accelerator in a non-clinical configuration. Burst mode delivery differs from continuous mode delivery, used by Elekta's VMAT (Elekta Ltd, Crawley, UK) and Varian's RapidArc (Varian Medical Systems, Palo Alto, CA, USA) implementations, in that dose is not delivered while MLC leaves are moving. Instead, dose is delivered in bursts over very short arc angles and only after an MLC segment shape has been completely formed and verified by the controller. The new system was confirmed to be capable of delivering a wide array of clinically relevant treatment plans, without machine fault or other delivery anomalies. Dosimetric accuracy of the modulated arc platform, as well as the Prowess (Prowess Inc., Concord, CA, USA) prototype treatment planning version utilized here, was quantified and confirmed, and delivery times were measured as significantly brief, even with large hypofractionated doses. The burst mode modulated arc approach evaluated here appears to represent a capable, accurate and efficient delivery approach.

  16. Evolution on neutral networks accelerates the ticking rate of the molecular clock

    PubMed Central

    Manrubia, Susanna; Cuesta, José A.

    2015-01-01

    Large sets of genotypes give rise to the same phenotype, because phenotypic expression is highly redundant. Accordingly, a population can accept mutations without altering its phenotype, as long as the genotype mutates into another one on the same set. By linking every pair of genotypes that are mutually accessible through mutation, genotypes organize themselves into neutral networks (NNs). These networks are known to be heterogeneous and assortative, and these properties affect the evolutionary dynamics of the population. By studying the dynamics of populations on NNs with arbitrary topology, we analyse the effect of assortativity, of NN (phenotype) fitness and of network size. We find that the probability that the population leaves the network is smaller the longer the time spent on it. This progressive ‘phenotypic entrapment’ entails a systematic increase in the overdispersion of the process with time and an acceleration in the fixation rate of neutral mutations. We also quantify the variation of these effects with the size of the phenotype and with its fitness relative to that of neighbouring alternatives. PMID:25392402

  17. Transgenic tobacco plants overexpressing the Nicta; CycD3; 4 gene demonstrate accelerated growth rates.

    PubMed

    Guo, Jia; Wang, Myeong Hyeon

    2008-07-31

    D-type cyclins control the onset of cell division and the response to extracellular signals during the G1 phase. In this study, we transformed a D-type cyclin gene, Nicta;CycD3;4, from Nicotiana tabacum using an Agrobacterium-mediated method. A predicted 1.1 kb cyclin gene was present in all of the transgenic plants, but not in wild-type. Northern analyses showed that the expression level of the Nicta;CycD3;4 gene in all of the transgenic plants was strong when compared to the wild-type plants, suggesting that Nicta;CycD3;4 gene driven by the CaMV 35S promoter was being overexpressed. Our results revealed that transgenic plants overexpressing Nicta;CycD3;4 had an accelerated growth rate when compared to wild-type plants, and that the transgenic plants exhibited a smaller cell size and a decreased cell population in young leaves when compared to wild-type plants.

  18. Atrial and ventricular rate response and patterns of heart rate acceleration during maternal-fetal terbutaline treatment of fetal complete heart block.

    PubMed

    Cuneo, Bettina F; Zhao, Hui; Strasburger, Janette F; Ovadia, Marc; Huhta, James C; Wakai, Ronald T

    2007-08-15

    Terbutaline is used to treat fetal bradycardia in the setting of complete heart block (CHB); however, little is known of its effects on atrial and ventricular beat rates or patterns of heart rate (HR) acceleration. Fetal atrial and ventricular beat rates were compared before and after transplacental terbutaline treatment (10 to 30 mg/day) by fetal echocardiography in 17 fetuses with CHB caused by immune-mediated damage to a normal conduction system (isoimmune, n = 8) or a congenitally malformed conduction system associated with left atrial isomerism (LAI, n = 9). While receiving terbutaline, 9 of the 17 fetuses underwent fetal magnetocardiography (fMCG) to assess maternal HR and rhythm, patterns of fetal HR acceleration, and correlation between fetal atrial and ventricular accelerations (i.e., AV correlation). Maternal HR and fetal atrial and ventricular beat rates increased with terbutaline. However, terbutaline's effects were greater on the atrial pacemaker(s) in fetuses with isoimmune CHB and greater on the ventricular pacemaker(s) in those with LAI-associated CHB. Patterns of fetal HR acceleration also differed between isoimmune and LAI CHB. Finally, despite increasing HR, terbutaline did not restore the normal coordinated response between atrial and ventricular accelerations in isoimmune or LAI CHB. In conclusion, the pathophysiologic heterogeneity of CHB is reflected in the differing effect of terbutaline on the atrial and ventricular pacemaker(s) and varying patterns of HR acceleration. However, regardless of the cause of CHB, terbutaline augments HR but not AV correlation, suggesting that its effects are determined by the conduction system defect rather than the autonomic control of the developing heart.

  19. Atrial and Ventricular Rate Response and Patterns of Heart Rate Acceleration during Maternal–Fetal Terbutaline Treatment of Fetal Complete Heart Block

    PubMed Central

    Cuneo, Bettina F.; Zhao, Hui; Strasburger, Janette F.; Ovadia, Marc; Huhta, James C.; Wakai, Ronald T.

    2012-01-01

    Terbutaline is used to treat fetal bradycardia in the setting of complete heart block (CHB); however, little is known of its effects on atrial and ventricular beat rates or patterns of heart rate (HR) acceleration. Fetal atrial and ventricular beat rates were compared before and after transplacental terbutaline treatment (10 to 30 mg/day) by fetal echocardiography in 17 fetuses with CHB caused by immune-mediated damage to a normal conduction system (isoimmune, n = 8) or a congenitally malformed conduction system associated with left atrial isomerism (LAI, n = 9). While receiving terbutaline, 9 of the 17 fetuses underwent fetal magnetocardiography (fMCG) to assess maternal HR and rhythm, patterns of fetal HR acceleration, and correlation between fetal atrial and ventricular accelerations (i.e., AV correlation). Maternal HR and fetal atrial and ventricular beat rates increased with terbutaline. However, terbutaline's effects were greater on the atrial pacemaker(s) in fetuses with isoimmune CHB and greater on the ventricular pacemaker(s) in those with LAI-associated CHB. Patterns of fetal HR acceleration also differed between isoimmune and LAI CHB. Finally, despite increasing HR, terbutaline did not restore the normal coordinated response between atrial and ventricular accelerations in isoimmune or LAI CHB. In conclusion, the pathophysiologic heterogeneity of CHB is reflected in the differing effect of terbutaline on the atrial and ventricular pacemaker(s) and varying patterns of HR acceleration. However, regardless of the cause of CHB, terbutaline augments HR but not AV correlation, suggesting that its effects are determined by the conduction system defect rather than the autonomic control of the developing heart. PMID:17697825

  20. Thermoneutral immersion exercise accelerates heart rate recovery: A potential novel training modality.

    PubMed

    Garzon, Mauricio; Dupuy, Olivier; Bosquet, Laurent; Nigam, Anil; Comtois, Alain Steve; Juneau, Martin; Gayda, Mathieu

    2017-04-01

    This study compared heart rate recovery (HRR) after incremental maximal exercise performed at the same external power output (Pext) on dry land ergocycle (DE) vs. immersible ergocycle (IE). Fifteen young healthy participants (30 ± 7 years, 13 men and 2 women) performed incremental maximal exercise tests on DE and on IE. The initial Pext on DE was 25 W and was increased by 25 W/min at a pedalling cadence between 60 and 80 rpm, while during IE immersion at chest level in thermoneutral water (30°C), the initial Pext deployment was at a cadence of 40 rpm which was increased by 10 rpm until 70 rpm and thereafter by 5 rpm until exhaustion. Gas exchange and heart rate (HR) were measured continuously during exercise and recovery for 5 min. Maximal HR (DE: 176 ± 15 vs. IE 169 ± 12 bpm) reached by the subjects in the two conditions did not differ (P > .05). Parasympathetic reactivation parameters (ΔHR from 10 to 300 s) were compared during the DE and IE HR recovery recordings. During the IE recovery, parasympathetic reactivation in the early phase was more predominant (HRR at Δ10-Δ60 s, P < .05), but similar in the late phase (HRR at Δ120-Δ300 s, P > .05) when compared to the DE condition. In conclusion, incremental maximal IE exercise at chest level immersion in thermoneutral water accelerates the early phase parasympathetic reactivation compared to DE in healthy young participants.

  1. The CLAS Forward Electromagnetic Calorimeter

    SciTech Connect

    M. Amarian; Geram Asryan; Kevin Beard; Will Brooks; Volker Burkert; Tom Carstens; Alan Coleman; Raphael Demirchyan; Yuri Efremenko; Hovanes Egiyan; Kim Egiyan; Herb Funsten; Vladimir Gavrilov; Kevin L. Giovanetti; R.M. Marshall; Berhard Mecking; R.C. Minehart; H. Mkrtchan; Mavrik Ohandjanyan; Youri Sharabian; L.C. Smith; Stepan Stepanyan; W.A. Stephens; T.Y. Tung; Carl Zorn

    2001-05-01

    The CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab utilizes six iron-free superconducting coils to provide an approximately toroidal magnetic field. The six sectors are instrumented individually to form six independent spectrometers. The forward region (8deg < (theta) < 45deg) of each sector is equipped with a lead-scintillator electromagnetic sampling calorimeter (EC), 16 radiation lengths thick, using a novel triangular geometry with stereo readout. With its good energy and position resolution, the EC is used to provide the primary electron trigger for CLAS. It is also used to reject pions, reconstruct pi-0 and eta decays and detect neutrons, This paper treats the design, construction and performance of the calorimeter.

  2. Compensation effects in hadron calorimeters

    SciTech Connect

    Gabriel, T.A.; Bishop, B.L.; Brau, J.; Di Ciaccio, A.; Goodman, M.; Wilson, R.

    1984-01-01

    The pros and cons of utilizing a fissionable material such as /sup 238/U to compensate for the nuclear binding energy losses in a hadron calorimeter are discussed. Fissionable material can return some lost energy to the particle cascade in terms of low-energy neutrons and gamma rays, but electromagnetic sampling inefficiencies (often called transition effects) and the detection medium which tries to convert this energy to a useable signal are just as important. 12 references.

  3. An elevated temperature titration calorimeter

    SciTech Connect

    Smith, J.R.; Zanonato, P.L.; Choppin, G.R. . Dept. of Chemistry)

    1991-06-01

    A variable-temperature (313 K to 353 K) titration calorimeter of high sensitivity has been constructed. The purpose of the calorimeter is to study temperature effects on the enthalpies of complex formation and of other reactions of metal cations such as hydrolysis and precipitation. Operation of the calorimetric system, including that final calculation of the heat released during titration, is automatic via computer control. Calibration tests of the calorimeter using 2-amino-2-hydroxymethyl-1,3-propanediol gave -(46.0 {plus minus} 0.3) kJ mol{sup {minus}1} and -(46.2 {plus minus} 0.2) kJ mol{sup {minus}1} for the enthalpy of protonation, at 318 K and at 343 K, respectively. For titrations of 2-bis(2-hydroxyethyl) amino-2-hydroxymethyl-1,3-propanediol, enthalpy of protonation values of -(28.4 {plus minus} 0.3) kJ mol{sup {minus}1} and -(29.3 {plus minus} 0.2) kJ mol{sup {minus}1} were obtained at 318 K and at 343 K, respectively. 6 refs., 3 figs., 2 tabs.

  4. Examining the limits of time reweighting and Kramers' rate theory to obtain correct kinetics from accelerated molecular dynamics.

    PubMed

    Xin, Yao; Doshi, Urmi; Hamelberg, Donald

    2010-06-14

    Accelerated molecular dynamics simulations are routinely being used to recover the correct canonical probability distributions corresponding to the original potential energy landscape of biomolecular systems. However, the limits of time reweighting, based on transition state theory, in obtaining true kinetic rates from accelerated molecular dynamics for biomolecular systems are less obvious. Here, we investigate this issue by studying the kinetics of cis-trans isomerization of peptidic omega bond by accelerated molecular dynamics. We find that time reweighting is valid for obtaining true kinetics when the original potential is not altered at the transition state regions, as expected. When the original potential landscape is modified such that the applied boost potential alters the transition state regions, time reweighting fails to reproduce correct kinetics and the reweighted rate is much slower than the true rate. By adopting the overdamped limit of Kramers' rate theory, we are successful in recovering correct kinetics irrespective of whether or not the transition state regions are modified. Furthermore, we tested the validity of the acceleration weight factor from the path integral formalism for obtaining the correct kinetics of cis-trans isomerization. It was found that this formulation of the weight factor is not suitable for long time scale processes such as cis-trans isomerization with high energy barriers.

  5. Language-Dependent Pitch Encoding Advantage in the Brainstem Is Not Limited to Acceleration Rates that Occur in Natural Speech

    ERIC Educational Resources Information Center

    Krishnan, Ananthanarayan; Gandour, Jackson T.; Smalt, Christopher J.; Bidelman, Gavin M.

    2010-01-01

    Experience-dependent enhancement of neural encoding of pitch in the auditory brainstem has been observed for only specific portions of native pitch contours exhibiting high rates of pitch acceleration, irrespective of speech or nonspeech contexts. This experiment allows us to determine whether this language-dependent advantage transfers to…

  6. Secondary Emission Calorimeter Sensor Development

    NASA Astrophysics Data System (ADS)

    Winn, David R.; Onel, Yasar

    2012-12-01

    In a Secondary Emission electron(SEe) detector module, Secondary Emission electrons (SEe) are generated from an SE surface/cathode, when charged hadronic or electromagnetic particles, particularly shower particles, penetrate an SE sampling module placed between absorber materials (Fe, Cu, Pb, W etc) in calorimeters. The SE cathode is a thin (10-50 nm thick) film (simple metal-oxides, or other higher yield materials) on the surface of a metal plate, which serves as the entrance “window” to a compact vacuum vessel (metal or metal-ceramic); this SE film cathode is analogous to a photocathode, and the SEe are similar to p.e., which are then amplified by dynodes, also is in a PMT. SE sensor modules can make use of electrochemically etched/machined or laser-cut metal mesh dynode sheets, as large as ~30 cm square, to amplify the Secondary Emission Electrons (SEe), much like those that compact metal mesh or mesh dynode PMT's use to amplify p.e.'s. The construction requirements easier than a PMT, since the entire final assembly can be done in air; there are no critical controlled thin film depositions, cesiation or other oxygen-excluded processes or other required vacuum activation, and consequently bake-out can be a refractory temperatures; the module is sealed by normal vacuum techniques (welding or brazing or other high temperature joinings), with a simple final heated vacuum pump-out and tip-off. The modules envisioned are compact, high gain, high speed, exceptionally radiation damage resistant, rugged, and cost effective, and can be fabricated in arbitrary tileable shapes. The SE sensor module anodes can be segmented transversely to sizes appropriate to reconstruct electromagnetic cores with high precision. The GEANT4 and existing calorimeter data estimated calorimeter response performance is between 35-50 Secondary Emission electrons per GeV, in a 1 cm thick Cu absorber calorimeter, with a gain per SEe > 105 per SEe, and an e/pi<1.2. The calorimeter pulse width is

  7. Development of an air flow thermal balance calorimeter

    NASA Technical Reports Server (NTRS)

    Sherfey, J. M.

    1972-01-01

    An air flow calorimeter, based on the idea of balancing an unknown rate of heat evolution with a known rate of heat evolution, was developed. Under restricted conditions, the prototype system is capable of measuring thermal wattages from 10 milliwatts to 1 watt, with an error no greater than 1 percent. Data were obtained which reveal system weaknesses and point to modifications which would effect significant improvements.

  8. Generalized Temporal Acceleration Scheme for Kinetic Monte Carlo Simulations of Surface Catalytic Processes by Scaling the Rates of Fast Reactions.

    PubMed

    Dybeck, Eric Christopher; Plaisance, Craig Patrick; Neurock, Matthew

    2017-02-14

    A novel algorithm has been developed to achieve temporal acceleration during kinetic Monte Carlo (KMC) simulations of surface catalytic processes. This algorithm allows for the direct simulation of reaction networks containing kinetic processes occurring on vastly disparate timescales which computationally overburden standard KMC methods. Previously developed methods for temporal acceleration in KMC have been designed for specific systems and often require a priori information from the user such as identifying the fast and slow processes. In the approach presented herein, quasi-equilibrated processes are identified automatically based on previous executions of the forward and reverse reactions. Temporal acceleration is achieved by automatically scaling the intrinsic rate constants of the quasi-equilibrated processes, bringing their rates closer to the timescales of the slow kinetically relevant non-equilibrated processes. All reactions are still simulated directly, although with modified rate constants. Abrupt changes in the underlying dynamics of the reaction network are identified during the simulation and the reaction rate constants are rescaled accordingly. The algorithm has been utilized here to model the Fischer-Tropsch synthesis reaction over ruthenium nanoparticles. This reaction network has multiple timescale-disparate processes which would be intractable to simulate without the aid of temporal acceleration. The accelerated simulations are found to give reaction rates and selectivities indistinguishable from those calculated by an equivalent mean-field kinetic model. The computational savings of the algorithm can span many orders of magnitude in realistic systems and the computational cost is not limited by the magnitude of the timescale disparity in the system processes. Furthermore, the algorithm has been designed in a generic fashion and can easily be applied to other surface catalytic processes of interest.

  9. Mechanical Design of the DAMPE BGO Calorimeter

    NASA Astrophysics Data System (ADS)

    Hu, Yiming; Wu, Jian; Feng, Changqing; Zhang, Yunlong; Chen, Dengyi; Chang, Jin

    The Dark Matter Particle Explorer, DAMPE, is a new designed satellite developed for the CASs new Innovation 2020 program. As the main component of DAMPE, the new designed BGO calorimeter consists of 308 BGO Crystals coupled with photomultiplier tube.The reliability and safety of the BGO Calorimeter structure play a very important role in the operation of whole detector. During the rocket launch, the calorimeter structure should be stable against vibration and environmental factors to ensure detector works in good conditions. In this article, we make the BGO calorimeter structure design, and then prove that it will work in the environments of rocket launch and flight.

  10. WE-G-17A-06: A Water Calorimeter for Use in MRI Linacs

    SciTech Connect

    De Prez, L; De Pooter, J; Jansen, B

    2014-06-15

    Purpose: At VSL, Dutch Metrology Institute, a new water calorimeter was developed with the purpose to replace the existing primary standard for absorbed dose to water in the Netherlands. The new water calorimeter is designed to be operable in medium- to high energy photon beams, electrons, protons as well as MRI integrated linear accelerators. VSL has operated a water calorimeter since 2001. This calorimeter formed the basis for the NCS-18 dosimetry protocol, which is commonly applied by medical physicists in the Netherlands and Belgium. Methods: The unit Gray is the unit of interest for measurement of the absorbed dose to water. Water calorimetry involves the measurement of a small temperature rise (0.24 mK/Gy) with an uncertainty of less than 1 μK/Gy at a temperature of 4 °C. Using extensive multi-physics simulations the new calorimeter's thermal performance was simulated before it was constructed at the end of 2013. With the advent of radiotherapy treatment units incorporating MR imaging the performance of the thermistor temperature sensors were characterized in a 1.5 T magnetic field. Results: A change of thermistor resistance was observed of less than 0.004% as a Result of the magneto-resistance effect in a 1.5 T magnetic field. Although a magneto-resistance effect was detectable, the effect on the temperature response in the water calorimeter was found to be negligible. Conclusion: With the realization of the new calorimeter operable in MRI linacs and designed for use in a variety of beam modalities, VSL is ready for accurate dosimetry in new advanced radiotherapy modalities. Due to the small form factor the calorimeter can be used on location in the actual therapy beam inside a 68 cm linac bore. This work was supported by EMRP grant HLT06. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.

  11. Dual-mass vibratory rate gyroscope with suppressed translational acceleration response and quadrature-error correction capability

    NASA Technical Reports Server (NTRS)

    Clark, William A. (Inventor); Juneau, Thor N. (Inventor); Lemkin, Mark A. (Inventor); Roessig, Allen W. (Inventor)

    2001-01-01

    A microfabricated vibratory rate gyroscope to measure rotation includes two proof-masses mounted in a suspension system anchored to a substrate. The suspension has two principal modes of compliance, one of which is driven into oscillation. The driven oscillation combined with rotation of the substrate about an axis perpendicular to the substrate results in Coriolis acceleration along the other mode of compliance, the sense-mode. The sense-mode is designed to respond to Coriolis accelerationwhile suppressing the response to translational acceleration. This is accomplished using one or more rigid levers connecting the two proof-masses. The lever allows the proof-masses to move in opposite directions in response to Coriolis acceleration. The invention includes a means for canceling errors, termed quadrature error, due to imperfections in implementation of the sensor. Quadrature-error cancellation utilizes electrostatic forces to cancel out undesired sense-axis motion in phase with drive-mode position.

  12. Accelerated forgetting? An evaluation on the use of long-term forgetting rates in patients with memory problems.

    PubMed

    Geurts, Sofie; van der Werf, Sieberen P; Kessels, Roy P C

    2015-01-01

    The main focus of this review was to evaluate whether long-term forgetting rates (delayed tests, days, to weeks, after initial learning) are more sensitive measures than standard delayed recall measures to detect memory problems in various patient groups. It has been suggested that accelerated forgetting might be characteristic for epilepsy patients, but little research has been performed in other populations. Here, we identified eleven studies in a wide range of brain injured patient groups, whose long-term forgetting patterns were compared to those of healthy controls. Signs of accelerated forgetting were found in three studies. The results of eight studies showed normal forgetting over time for the patient groups. However, most of the studies used only a recognition procedure, after optimizing initial learning. Based on these results, we recommend the use of a combined recall and recognition procedure to examine accelerated forgetting and we discuss the relevance of standard and optimized learning procedures in clinical practice.

  13. Accelerated forgetting? An evaluation on the use of long-term forgetting rates in patients with memory problems

    PubMed Central

    Geurts, Sofie; van der Werf, Sieberen P.; Kessels, Roy P. C.

    2015-01-01

    The main focus of this review was to evaluate whether long-term forgetting rates (delayed tests, days, to weeks, after initial learning) are more sensitive measures than standard delayed recall measures to detect memory problems in various patient groups. It has been suggested that accelerated forgetting might be characteristic for epilepsy patients, but little research has been performed in other populations. Here, we identified eleven studies in a wide range of brain injured patient groups, whose long-term forgetting patterns were compared to those of healthy controls. Signs of accelerated forgetting were found in three studies. The results of eight studies showed normal forgetting over time for the patient groups. However, most of the studies used only a recognition procedure, after optimizing initial learning. Based on these results, we recommend the use of a combined recall and recognition procedure to examine accelerated forgetting and we discuss the relevance of standard and optimized learning procedures in clinical practice. PMID:26106343

  14. Determination of the cosmological rate of change of G and the tidal accelerations of earth and moon from ancient and modern astronomical data

    NASA Technical Reports Server (NTRS)

    Muller, P. M.

    1976-01-01

    The theory and numerical analysis of ancient astronomical observations (1374 to 1715) are combined with modern data in a simultaneous solution for: the tidal acceleration of the lunar longitude; the observed apparent acceleration of the earth's rotation; the true nontidal geophysical part of this acceleration; and the rate of change in the gravitational constant. Provided are three independent determinations of a rate of change of G consistent with the Hubble Constant and a near zero nontidal rotational acceleration of the earth. The tidal accelerations are shown to have remained constant during the historical period within uncertainties. Ancient and modern solar system data, and extragalactic observations provided a completely consistent astronomical and cosmological scheme.

  15. SCA controller for the ATLAS calorimeter

    SciTech Connect

    Gingrich, D.M.; Hewlett, J.C.; Holm, L.

    1997-12-31

    The front-end readout of the ATLAS liquid argon calorimeter will store data locally in analog pipeline memories at the LHC beam crossing frequency of 40 MHz. Switched capacitor array chips meeting the ATLAS readout requirements will be used. These new chips axe capable of simultaneous read and write operations, and allow random access to storage locations. To utilize these essential design features requires a substantial amount of fast control and address bookkeeping logic. We have designed a controller capable of operating the pipelines as analog random access memories and that satisfies the ATLAS readout requirements. The pipeline controller manages the data of 144 time samples and can operate at a mean trigger rate of about 75 kHz, when reading out five time samples per event. We are currently prototyping an integrated version of the controller implemented in a FPGA from Xilinx.

  16. Thin liquid sheet target capabilities for ultra-intense laser acceleration of ions at a kHz repetition rate

    NASA Astrophysics Data System (ADS)

    Klim, Adam; Morrison, J. T.; Orban, C.; Feister, S.; Ngirmang, G. K.; Smith, J.; Frische, K.; Peterson, A. C.; Chowdhury, E. A.; Freeman, R. R.; Roquemore, W. M.

    2016-10-01

    The success of laser-accelerated ion experiments depends crucially on a number of factors including how thin the targets can be created. We present experimental results demonstrating extremely thin (under 200 nm) water sheet targets that can be used for ultra-intense laser-accelerated ion experiments conducted at the Air Force Research Laboratory at Wright-Patterson Air Force Base. Importantly, these experiments operate at a kHz repetition rate and the recovery time of the liquid targets is fast enough to allow the laser to interact with a refreshed, thin target on every shot. We present results from liquid water targets which are useful for proton acceleration experiments via the mechanism of Target Normal Sheath Acceleration (TNSA). In future work, we will create thin sheets from deuterated water in order to perform laser-accelerated deuteron experiments. This research was sponsored by the Quantum and Non-Equilibrium Processes Division of the AFOSR, under the management of Dr. Enrique Parra, and support from the DOD HPCMP Internship Program.

  17. Technology evaluation of man-rated acceleration test equipment for vestibular research

    NASA Technical Reports Server (NTRS)

    Taback, I.; Kenimer, R. L.; Butterfield, A. J.

    1983-01-01

    The considerations for eliminating acceleration noise cues in horizontal, linear, cyclic-motion sleds intended for both ground and shuttle-flight applications are addressed. the principal concerns are the acceleration transients associated with change in direction-of-motion for the carriage. The study presents a design limit for acceleration cues or transients based upon published measurements for thresholds of human perception to linear cyclic motion. The sources and levels for motion transients are presented based upon measurements obtained from existing sled systems. The approaches to a noise-free system recommends the use of air bearings for the carriage support and moving-coil linear induction motors operating at low frequency as the drive system. Metal belts running on air bearing pulleys provide an alternate approach to the driving system. The appendix presents a discussion of alternate testing techniques intended to provide preliminary type data by means of pendulums, linear motion devices and commercial air bearing tables.

  18. Acceleration and Deceleration Capacity of Fetal Heart Rate in an In-Vivo Sheep Model

    PubMed Central

    Rivolta, Massimo W.; Stampalija, Tamara; Casati, Daniela; Richardson, Bryan S.; Ross, Michael G.; Frasch, Martin G.; Bauer, Axel; Ferrazzi, Enrico; Sassi, Roberto

    2014-01-01

    Background Fetal heart rate (FHR) variability is an indirect index of fetal autonomic nervous system (ANS) integrity. FHR variability analysis in labor fails to detect early hypoxia and acidemia. Phase-rectified signal averaging (PRSA) is a new method of complex biological signals analysis that is more resistant to non-stationarities, signal loss and artifacts. It quantifies the average cardiac acceleration and deceleration (AC/DC) capacity. Objective The aims of the study were: (1) to investigate AC/DC in ovine fetuses exposed to acute hypoxic-acidemic insult; (2) to explore the relation between AC/DC and acid-base balance; and (3) to evaluate the influence of FHR decelerations and specific PRSA parameters on AC/DC computation. Methods Repetitive umbilical cord occlusions (UCOs) were applied in 9 pregnant near-term sheep to obtain three phases of MILD, MODERATE, and SEVERE hypoxic-acidemic insult. Acid-base balance was sampled and fetal ECGs continuously recorded. AC/DC were calculated: (1) for a spectrum of T values (T = 1÷50 beats; the parameter limits the range of oscillations detected by PRSA); (2) on entire series of fetal RR intervals or on “stable” series that excluded FHR decelerations caused by UCOs. Results AC and DC progressively increased with UCOs phases (MILD vs. MODERATE and MODERATE vs. SEVERE, p<0.05 for DC  = 2–5, and AC  = 1–3). The time evolution of AC/DC correlated to acid-base balance (0.4<<0.9, p<0.05) with the highest for . PRSA was not independent from FHR decelerations caused by UCOs. Conclusions This is the first in-vivo evaluation of PRSA on FHR analysis. In the presence of acute hypoxic-acidemia we found increasing values of AC/DC suggesting an activation of ANS. This correlation was strongest on time scale dominated by parasympathetic modulations. We identified the best performing parameters (), and found that AC/DC computation is not independent from FHR decelerations. These findings establish the basis for

  19. SUITABILITY OF A NEW CALORIMETER FOR EXOTIC MESON SEARCHES

    SciTech Connect

    Bookwalter, C.; Ostrovidov, A.; Eugenio, P.

    2007-01-01

    Exotic mesons, particles that have quantum numbers that are inaccessible to conventional quark-model mesons, are predicted by quantum chromodynamics (QCD), but past experiments seeking to identify exotic candidates have produced controversial results. The HyCLAS experiment (E04005) at Thomas Jefferson National Accelerator Facility (TJNAF) proposes the use of the Continuous Electron Beam Accelerator Facility (CEBAF) Large Acceptance Spectrometer (CLAS) in Hall B to study the photoproduction of exotic mesons. However, the base detector package at CLAS is not ideal for observing and measuring neutral particles, particularly at forward angles. The Deeply Virtual Compton Scattering (DVCS) experiment at TJNAF has commissioned a new calorimeter for detecting small-angle photons, but studies must be performed to determine its suitability for a meson spectroscopy experiment. The ηπ system has been under especial scrutiny in the community as a source for potential exotics, so the new calorimeter’s ability at reconstructing these resonances must be evaluated. To achieve this, the invariant mass of showers in the calorimeter are reconstructed. Also, two electroproduction reaction channels analogous to photoproduction channels of interest to HyCLAS are examined in DVCS data. It is found that, while not ideal, the new calorimeter will allow access to additional reaction channels, and its inclusion in HyCLAS is warranted. Results in basic shower reconstruction show that the calorimeter has good effi ciency in resolving π° decays, but its η reconstruction is not as strong. When examining ep → epπ°η, preliminary reconstruction of the ηπ° system shows faint signals in the a0(980) region. In the ep → e n π+ η channel, preliminary reconstruction of the ηπ+ system gave good signals in the a0(980) and a2(1320) regions, but statistics were poor. While more analyses are necessary to improve statistics and remove background, these preliminary results support the claim

  20. Response of the D0 calorimeter to cosmic ray muons

    SciTech Connect

    Kotcher, J.

    1992-10-01

    The D0 Detector at the Fermi National Accelerator Laboratory is a large multi-purpose detector facility designed for the study of proton-antiproton collision products at the center-of-mass energy of 2 TeV. It consists of an inner tracking volume, hermetic uranium/liquid argon sampling calorimetry, and an outer 4{pi} muon detector. In preparation for our first collider run, the collaboration organized a Cosmic Ray Commissioning Run, which took place from February - May of 1991. This thesis is a detailed study of the response of the central calorimeter to cosmic ray muons as extracted from data collected during this run.

  1. ATLAS liquid argon calorimeter front end electronics

    NASA Astrophysics Data System (ADS)

    Buchanan, N. J.; Chen, L.; Gingrich, D. M.; Liu, S.; Chen, H.; Damazio, D.; Densing, F.; Duffin, S.; Farrell, J.; Kandasamy, S.; Kierstead, J.; Lanni, F.; Lissauer, D.; Ma, H.; Makowiecki, D.; Muller, T.; Radeka, V.; Rescia, S.; Ruggiero, R.; Takai, H.; Wolniewicz, K.; Ghazlane, H.; Hoummada, A.; Hervas, L.; Hott, T.; Wilkens, H. G.; Ban, J.; Boettcher, S.; Brooijmans, G.; Chi, C.-Y.; Caughron, S.; Cooke, M.; Copic, K.; Dannheim, D.; Gara, A.; Haas, A.; Katsanos, I.; Parsons, J. A.; Simion, S.; Sippach, W.; Zhang, L.; Zhou, N.; Eckstein, P.; Kobel, M.; Ladygin, E.; Auge, E.; Bernier, R.; Bouchel, M.; Bozzone, A.; Breton, D.; de la Taille, C.; Falleau, I.; Fournier, D.; Imbert, P.; Martin-Chassard, G.; Perus, A.; Richer, J. P.; Seguin Moreau, N.; Serin, L.; Tocut, V.; Veillet, J.-J.; Zerwas, D.; Colas, J.; Dumont-Dayot, N.; Massol, N.; Perrodo, P.; Perrot, G.; Wingerter-Seez, I.; Escalier, M.; Hubaut, F.; Laforge, B.; LeDortz, O.; Schwemling, Ph; Collot, J.; Dzahini, D.; Gallin-Martel, M.-L.; Martin, P.; Cwienk, W. D.; Fent, J.; Kurchaninov, L.; Citterio, M.; Mazzanti, M.; Tartarelli, F.; Bansal, V.; Boulahouache, C.; Cleland, W.; Liu, B.; McDonald, J.; Paolone, V.; Rabel, J.; Savinov, V.; Zuk, G.; Benslama, K.; Borgeaud, P.; de la Broïse, X.; Delagnes, E.; LeCoguie, A.; Mansoulié, B.; Pascual, J.; Teiger, J.; Dinkespiler, B.; Liu, T.; Stroynowski, R.; Ye, J.; Zarzhitsky, P.; Grahn, K.-J.; Hansson, P.; Lund-Jensen, B.; Chu, M. L.; Lee, S.-C.; Su, D. S.; Teng, P. K.; Braun, H. M.

    2008-09-01

    The ATLAS detector has been designed for operation at CERN's Large Hadron Collider. ATLAS includes a complex system of liquid argon calorimeters. This paper describes the architecture and implementation of the system of custom front end electronics developed for the readout of the ATLAS liquid argon calorimeters.

  2. Correlations of metabolic rate and body acceleration in three species of coastal sharks under contrasting temperature regimes.

    PubMed

    Lear, Karissa O; Whitney, Nicholas M; Brewster, Lauran R; Morris, Jack J; Hueter, Robert E; Gleiss, Adrian C

    2017-02-01

    The ability to produce estimates of the metabolic rate of free-ranging animals is fundamental to the study of their ecology. However, measuring the energy expenditure of animals in the field has proved difficult, especially for aquatic taxa. Accelerometry presents a means of translating metabolic rates measured in the laboratory to individuals studied in the field, pending appropriate laboratory calibrations. Such calibrations have only been performed on a few fish species to date, and only one where the effects of temperature were accounted for. Here, we present calibrations between activity, measured as overall dynamic body acceleration (ODBA), and metabolic rate, measured through respirometry, for nurse sharks (Ginglymostoma cirratum), lemon sharks (Negaprion brevirostris) and blacktip sharks (Carcharhinus limbatus). Calibrations were made at a range of volitional swimming speeds and experimental temperatures. Linear mixed models were used to determine a predictive equation for metabolic rate based on measured ODBA values, with the optimal model using ODBA in combination with activity state and temperature to predict metabolic rate in lemon and nurse sharks, and ODBA and temperature to predict metabolic rate in blacktip sharks. This study lays the groundwork for calculating the metabolic rate of these species in the wild using acceleration data.

  3. Silicon Photomultiplier Characterization for sPHENIX Calorimeters

    NASA Astrophysics Data System (ADS)

    Tanner, Meghan; Skoby, Michael; Aidala, Christine; Sphenix Collaboration

    2016-09-01

    Silicon photomultipliers (SiPMs) are preferable to photomultiplier tubes due to their small size, insensitivity to magnetic fields, low operating voltage, and capability of detecting single photons. The sPHENIX collaboration at RHIC will use SiPMs in their proposed electromagnetic and hadronic calorimeters. The University of Michigan is assembling and implementing a test stand to characterize the dark count rate, temperature dependence, gain, and photon detection efficiency of SiPMs. To more accurately determine the dark count rate, we have constructed a light tight box to isolate the SiPM, which surrounds an electronics enclosure that protects the SiPM circuitry, and installed software to record the output signals. With this system, we will begin to collect data and optimize the system to test arrays of SiPMs instead of single devices as the proposed calorimeters will require testing approximately 115,000 SiPMs.

  4. 5.8 X-ray Calorimeters

    NASA Technical Reports Server (NTRS)

    Porter, F. Scott

    2008-01-01

    X-ray calorimeter instruments for astrophysics have seen rapid development since they were invented in 1984. The prime instrument on all currently planned X-ray spectroscopic observatories is based on calorimeter technology. This relatively simple detection concept that senses the energy of an incident photon by measuring the temperature rise of an absorber material at very low temperatures, can form the basis of a very high performance, non-dispersive spectrometer. State-of-the-art calorimeter instruments have resolving powers of over 3000, large simultaneous band-passes, and near unit efficiency. This coupled with the intrinsic imaging capability of a pixilated x-ray calorimeter array, allows true spectral-spatial instruments to be constructed. In this chapter I briefly review the detection scheme, the state-of-the-art in X-ray calorimeter instruments and the future outlook for this technology.

  5. In vivo human left-to-right ventricular differences in rate adaptation transiently increase pro-arrhythmic risk following rate acceleration.

    PubMed

    Bueno-Orovio, Alfonso; Hanson, Ben M; Gill, Jaswinder S; Taggart, Peter; Rodriguez, Blanca

    2012-01-01

    Left-to-right ventricular (LV/RV) differences in repolarization have been implicated in lethal arrhythmias in animal models. Our goal is to quantify LV/RV differences in action potential duration (APD) and APD rate adaptation and their contribution to arrhythmogenic substrates in the in vivo human heart using combined in vivo and in silico studies. Electrograms were acquired from 10 LV and 10 RV endocardial sites in 15 patients with normal ventricles. APD and APD adaptation were measured during an increase in heart rate. Analysis of in vivo electrograms revealed longer APD in LV than RV (207.8 ± 21.5 vs 196.7 ± 20.1 ms; P<0.05), and slower APD adaptation in LV than RV (time constant τ(s) =47.0 ± 14.3 vs 35.6 ± 6.5 s; P<0.05). Following rate acceleration, LV/RV APD dispersion experienced an increase of up to 91% in 12 patients, showing a strong correlation (r(2) =0.90) with both initial dispersion and LV/RV difference in slow adaptation. Pro-arrhythmic implications of measured LV/RV functional differences were studied using in silico simulations. Results show that LV/RV APD and APD adaptation heterogeneities promote unidirectional block following rate acceleration, albeit being insufficient for establishment of reentry in normal hearts. However, in the presence of an ischemic region at the LV/RV junction, LV/RV heterogeneity in APD and APD rate adaptation promotes reentrant activity and its degeneration into fibrillatory activity. Our results suggest that LV/RV heterogeneities in APD adaptation cause a transient increase in APD dispersion in the human ventricles following rate acceleration, which promotes unidirectional block and wave-break at the LV/RV junction, and may potentiate the arrhythmogenic substrate, particularly in patients with ischemic heart disease.

  6. Acceleration of ventricular rate by amiodarone in atrial fibrillation associated with the Wolff-Parkinson-White syndrome

    PubMed Central

    Sheinman, Bryan D; Evans, Tom

    1982-01-01

    Amiodarone has proved to be a valuable drug in atrial fibrillation associated with the Wolff-Parkinson-White syndrome. When it was administered to a patient with this syndrome in atrial fibrillation, who had previously suffered an inferior myocardial infarction, the ventricular rate accelerated from 170 to 230 beats/minute. This unusual case emphasises the need for full electrophysiological assessment of patients with the Wolff-Parkinson-White syndrome for whom amiodarone treatment is being considered. Imagesp1000-a PMID:6812745

  7. A calorimeter for multilayer insulation (MLI) performance measurements at variable temperature

    NASA Astrophysics Data System (ADS)

    Celik, D.; Hurd, J.; Klimas, R.; Van Sciver, S. W.

    2013-05-01

    Here we describe a concentric cylindrical calorimeter with radiation guards developed to measure the thermal performance of multilayer insulation (MLI) for low temperature applications. One unique feature of this calorimeter is its ability to independently control the boundary temperatures between room temperature and about 15 K using two single-stage Gifford-McMahon cryocoolers. Also, unlike the existing calorimeters that use the evaporation rate of a liquid cryogen to measure the heat load, in the present system the total heat transfer through the MLI is measured by recording the temperature difference across a calibrated heat load support rod that connects the cold inner cylinder to the lower temperature cryocooler. This design allows the continuous mapping of MLI performance over a much wider temperature range with independently controlled boundary conditions. The calorimeter is also suitable for performing a variety of radiation heat transfer experiments including the determination of the temperature dependence of the total emissivity.

  8. Multiple Metazoan Life-span Interventions Exhibit a Sex-specific Strehler-Mildvan Inverse Relationship Between Initial Mortality Rate and Age-dependent Mortality Rate Acceleration.

    PubMed

    Shen, Jie; Landis, Gary N; Tower, John

    2017-01-01

    The Gompertz equation describes survival in terms of initial mortality rate (parameter a), indicative of health, and age-dependent acceleration in mortality rate (parameter b), indicative of aging. Gompertz parameters were analyzed for several published studies. In Drosophila females, mating increases egg production and decreases median life span, consistent with a trade-off between reproduction and longevity. Mating increased parameter a, causing decreased median life span, whereas time parameter b was decreased. The inverse correlation between parameters indicates the Strehler-Mildvan (S-M) relationship, where loss of low-vitality individuals yields a cohort with slower age-dependent mortality acceleration. The steroid hormone antagonist mifepristone/RU486 reversed these effects. Mating and mifepristone showed robust S-M relationships across genotypes, and dietary restriction showed robust S-M relationship across diets. Because nutrient optima differed between females and males, the same manipulation caused opposite effects on mortality rates in females versus males across a range of nutrient concentrations. Similarly, p53 mutation in Drosophila and mTOR mutation in mice caused increased median life span associated with opposite direction changes in mortality rate parameters in females versus males. The data demonstrate that dietary and genetic interventions have sex-specific and sometimes sexually opposite effects on mortality rates consistent with sexual antagonistic pleiotropy.

  9. The Impact of Back-Sputtered Carbon on the Accelerator Grid Wear Rates of the NEXT and NSTAR Ion Thrusters

    NASA Technical Reports Server (NTRS)

    Soulas, George C.

    2013-01-01

    A study was conducted to quantify the impact of back-sputtered carbon on the downstream accelerator grid erosion rates of the NASA's Evolutionary Xenon Thruster (NEXT) Long Duration Test (LDT1). A similar analysis that was conducted for the NASA's Solar Electric Propulsion Technology Applications Readiness Program (NSTAR) Life Demonstration Test (LDT2) was used as a foundation for the analysis developed herein. A new carbon surface coverage model was developed that accounted for multiple carbon adlayers before complete surface coverage is achieved. The resulting model requires knowledge of more model inputs, so they were conservatively estimated using the results of past thin film sputtering studies and particle reflection predictions. In addition, accelerator current densities across the grid were rigorously determined using an ion optics code to determine accelerator current distributions and an algorithm to determine beam current densities along a grid using downstream measurements. The improved analysis was applied to the NSTAR test results for evaluation. The improved analysis demonstrated that the impact of back-sputtered carbon on pit and groove wear rate for the NSTAR LDT2 was negligible throughout most of eroded grid radius. The improved analysis also predicted the accelerator current density for transition from net erosion to net deposition considerably more accurately than the original analysis. The improved analysis was used to estimate the impact of back-sputtered carbon on the accelerator grid pit and groove wear rate of the NEXT Long Duration Test (LDT1). Unlike the NSTAR analysis, the NEXT analysis was more challenging because the thruster was operated for extended durations at various operating conditions and was unavailable for measurements because the test is ongoing. As a result, the NEXT LDT1 estimates presented herein are considered preliminary until the results of future post-test analyses are incorporated. The worst-case impact of carbon

  10. The Impact of Back-Sputtered Carbon on the Accelerator Grid Wear Rates of the NEXT and NSTAR Ion Thrusters

    NASA Technical Reports Server (NTRS)

    Soulas, George C.

    2013-01-01

    A study was conducted to quantify the impact of back-sputtered carbon on the downstream accelerator grid erosion rates of the NEXT (NASA's Evolutionary Xenon Thruster) Long Duration Test (LDT1). A similar analysis that was conducted for the NSTAR (NASA's Solar Electric Propulsion Technology Applications Readiness Program) Life Demonstration Test (LDT2) was used as a foundation for the analysis developed herein. A new carbon surface coverage model was developed that accounted for multiple carbon adlayers before complete surface coverage is achieved. The resulting model requires knowledge of more model inputs, so they were conservatively estimated using the results of past thin film sputtering studies and particle reflection predictions. In addition, accelerator current densities across the grid were rigorously determined using an ion optics code to determine accelerator current distributions and an algorithm to determine beam current densities along a grid using downstream measurements. The improved analysis was applied to the NSTAR test results for evaluation. The improved analysis demonstrated that the impact of back-sputtered carbon on pit and groove wear rate for the NSTAR LDT2 was negligible throughout most of eroded grid radius. The improved analysis also predicted the accelerator current density for transition from net erosion to net deposition considerably more accurately than the original analysis. The improved analysis was used to estimate the impact of back-sputtered carbon on the accelerator grid pit and groove wear rate of the NEXT Long Duration Test (LDT1). Unlike the NSTAR analysis, the NEXT analysis was more challenging because the thruster was operated for extended durations at various operating conditions and was unavailable for measurements because the test is ongoing. As a result, the NEXT LDT1 estimates presented herein are considered preliminary until the results of future posttest analyses are incorporated. The worst-case impact of carbon back

  11. Scanning calorimeter for nanoliter-scale liquid samples

    NASA Astrophysics Data System (ADS)

    Olson, E. A.; Efremov, M. Yu.; Kwan, A. T.; Lai, S.; Petrova, V.; Schiettekatte, F.; Warren, J. T.; Zhang, M.; Allen, L. H.

    2000-10-01

    We introduce a scanning calorimeter for use with a single solid or liquid sample with a volume down to a few nanoliters. Its use is demonstrated with the melting of 52 nL of indium, using heating rates from 100 to 1000 K/s. The heat of fusion was measured to within 5% of the bulk value, and the sensitivity of the measurement was ±7 μW. The heat of vaporization of water was measured in the scanning mode to be within ±23% of the bulk value by actively vaporizing water droplets from 2 to 100 nL in volume. Results within 25% were obtained for the heat of vaporization by using the calorimeter in a heat-conductive mode and measuring the passive evaporation of water. Temperature measurements over a period of 10 h had a standard deviation of 3 mK.

  12. ANL four-meter calorimeter design and operation manual

    SciTech Connect

    Perry, R.B.; Lewis, R.N.; Youngdahl, G.A.; Jung, E.A.; Roche, C.T.

    1980-02-01

    The four-meter fuel rod calorimetric system measures the thermal power produced by radioactive decay of fuel rods containing Pu. The Pu mass is related to the measured power through the weighted average of the product of the isotopic decay energies and the decay constants of the Pu isotopes present. U content has no effect since the thermal power produced by the U nuclides is insignificant when compared to Pu. Radiations from Pu are alpha particles and low-energy photons. This calorimeter will measure samples producing power up to 1.5 watts at a rate of one sample every 120 min. The instrument consists of a data-acquisition module made up of a microprocessor, with an 8K-byte nonvolatile memory, a control cabinet and the calorimeter chamber. (FS)

  13. The readout driver (ROD) for the ATLAS liquid argon calorimeters

    NASA Astrophysics Data System (ADS)

    Efthymiopoulos, Ilias

    2001-04-01

    The Readout Driver (ROD) for the Liquid Argon calorimeter of the ATLAS detector is described. Each ROD module receives triggered data from 256 calorimeter cells via two fiber-optics 1.28 Gbit/s links with a 100 kHz event rate (25 kbit/event). Its principal function is to determine the precise energy and timing of the signal from discrete samples of the waveform, taken each period of the LHC clock (25 ns). In addition, it checks, histograms, and formats the digital data stream. A demonstrator system, consisting of a motherboard and several daughter-board processing units (PUs) was constructed and is currently used for tests in the lab. The design of this prototype board is presented here. The board offers maximum modularity and allows the development and testing of different PU designs based on today's leading integer and floating point DSPs.

  14. Longitudinally segmented shashlik calorimeters with SiPM readout

    NASA Astrophysics Data System (ADS)

    Berra, A.; Cecchini, S.; Cindolo, F.; Ferdinando, D. Di; Jollet, C.; Longhin, A.; Ludovici, L.; Mandrioli, G.; Mauri, N.; Meregaglia, A.; Paoloni, A.; Pasqualini, L.; Patrizii, L.; Pozzato, M.; Pupilli, F.; Prest, M.; Sirri, G.; Terranova, F.; Vallazza, E.; Votano, L.

    2017-02-01

    The goal of the INFN SCENTT R&D project is to develop the calorimeter technologies for the instrumentation of decay tunnels in conventional neutrino beams. This instrumentation is required to achieve a substantial improvement in the uncertainty on neutrino fluxes for the next generation cross section experiments. In particular, we are designing a positron tagger based on purely calorimetric techniques that is able to measure the rate and the spectrum of the positrons produced in the K+ →e+π0νe decay. The νe flux is inferred from the positron rate in the decay tunnel. Considering the large dimensions of the tagger, the most cost effective technology is based on small modules of Fe/Scintillator shashlik calorimeters, with adequate segmentation and energy resolution to efficiently tag the positrons over the charged pion background. This contribution presents preliminary results obtained with two shashlik calorimeter prototypes readout with an array of Silicon PhotoMultipliers and tested at the CERN PS-T9 beamline.

  15. First results from the SLD silicon calorimeters

    NASA Astrophysics Data System (ADS)

    Berridge, S. C.; Bugg, W. M.; Kroeger, R. S.; Weidemann, A. W.; White, S. L.; Brau, J. E.; Frey, R.; Furuno, K.; Huber, J.; Hwang, H.

    1992-07-01

    The small-angle calorimeters of the SLD were successfully operated during the recent SLC engineering run. The Luminosity Monitor and Small-Angle Tagger (LMSAT) covers the angular region between 28 and 68 milliradians from the beam axis, while the Medium-Angle Silicon Calorimeter (MASC) covers the 68-190 milliradian region. Both are silicon-tungsten sampling calorimeters; the LMSAT employs 23 layers of 0.86 X(sub 0) sampling, while the MASC has 10 layers of 1.74 X(sub 0) sampling. We present results from the first run of the SLC with the SLD on beamline.

  16. MARK II end cap calorimeter electronics

    SciTech Connect

    Jared, R.C.; Haggerty, J.S.; Herrup, D.A.; Kirsten, F.A.; Lee, K.L.; Olson, S.R.; Wood, D.R.

    1985-10-01

    An end cap calorimeter system has been added to the MARK II detector in preparation for its use at the SLAC Linear Collider. The calorimeter uses 8744 rectangular proportional counter tubes. This paper describes the design features of the data acquisition electronics that has been installed on the calorimeter. The design and use of computer-based test stands for the amplification and signal-shaping components is also covered. A portion of the complete system has been tested in a beam at SLAC. In these initial tests, using only the calibration provided by the test stands, a resolution of 18%/..sqrt..E was achieved.

  17. First results from the SLD silicon calorimeters

    SciTech Connect

    Berridge, S.C.; Bugg, W.M.; Kroeger, R.S.; Weidemann, A.W.; White, S.L.; Brau, J.E.; Frey, R.; Furuno, K.; Huber, J.; Hwang, H.; Park, H.; Pitts, K.T.; Zeitlin, C.J.; Gioumousis, A.; Haller, G.; Seward, P.

    1992-07-01

    The small-angle calorimeters of the SLD were successfully operated during the recent SLC engineering run. The Luminosity Monitor and Small-Angle Tagger (LMSAT) covers the angular region between 28 and 68 milliradians from the beam axis, while the Medium-Angle Silicon Calorimeter (MASC) covers the 68--190 milliradian region. Both are silicon-tungsten sampling calorimeters; the LMSAT employs 23 layers of 0.86 X{sub 0} sampling, while the MASC has 10 layers of 1.74 X{sub 0} sampling. We present results from the first run of the SLC with the SLD on beamline.

  18. Cesium Iodide Crystal Calorimeter of the Proton Computed Tomography (pCT) Imager

    NASA Astrophysics Data System (ADS)

    Missaghian, Jessica; Sadrozinski, Hartmut; Colby, Brian; Rykalin, Victor; Hurley, Ford

    2009-11-01

    Researchers at SCIPP, LLMU and NIU have collaborated to make a functioning proton imager. Proton Computed Tomography (pCT) is designated to be applied in proton therapy of human cancer systems. It will image head-sized phantom objects and provide excellent space and energy resolution using a silicon microstrip tracker and crystal calorimetry. The residual energy could be measured with precision of a few percent using a Cesium Iodide crystal calorimeter. A single element of the CsI(TI) calorimeter was tested in order to understand the behavior of the future calorimeter system. We present test results on a CsI(TI) calorimeter element with proton beams of 35, 100 and 200MeV. The detector element was designed to comply with the demands of high energy resolution of a few percent and a dynamic range of two orders of magnitude (1-300MeV) under a counting rate of 10 kHz per channel. We also report on cosmic measurement results of each crystal of the future calorimeter matrix. A detailed description of the calorimeter data acquisition system will be given.

  19. Fire tests and analyses of a rail cask-sized calorimeter.

    SciTech Connect

    Figueroa, Victor G.; Lopez, Carlos; Suo-Anttila, Ahti Jorma; Greiner, Miles

    2010-10-01

    Three large open pool fire experiments involving a calorimeter the size of a spent fuel rail cask were conducted at Sandia National Laboratories Lurance Canyon Burn Site. These experiments were performed to study the heat transfer between a very large fire and a large cask-like object. In all of the tests, the calorimeter was located at the center of a 7.93-meter diameter fuel pan, elevated 1 meter above the fuel pool. The relative pool size and positioning of the calorimeter conformed to the required positioning of a package undergoing certification fire testing. Approximately 2000 gallons of JP-8 aviation fuel were used in each test. The first two tests had relatively light winds and lasted 40 minutes, while the third had stronger winds and consumed the fuel in 25 minutes. Wind speed and direction, calorimeter temperature, fire envelop temperature, vertical gas plume speed, and radiant heat flux near the calorimeter were measured at several locations in all tests. Fuel regression rate data was also acquired. The experimental setup and certain fire characteristics that were observed during the test are described in this paper. Results from three-dimensional fire simulations performed with the Cask Analysis Fire Environment (CAFE) fire code are also presented. Comparisons of the thermal response of the calorimeter as measured in each test to the results obtained from the CAFE simulations are presented and discussed.

  20. Accelerated rate of molecular evolution for vittarioid ferns is strong and not driven by selection.

    PubMed

    Rothfels, Carl J; Schuettpelz, Eric

    2014-01-01

    Molecular evolutionary rate heterogeneity-the violation of a molecular clock-is a prominent feature of many phylogenetic data sets. It has particular importance to systematists not only because of its biological implications, but also for its practical effects on our ability to infer and date evolutionary events. Here we show, using both maximum likelihood and Bayesian approaches, that a remarkably strong increase in substitution rate in the vittarioid ferns is consistent across the nuclear and plastid genomes. Contrary to some expectations, this rate increase is not due to selective forces acting at the protein level on our focal loci. The vittarioids bear no signature of the change in the relative strengths of selection and drift that one would expect if the rate increase was caused by altered post-mutation fixation rates. Instead, the substitution rate increase appears to stem from an elevated supply of mutations, perhaps limited to the vittarioid ancestral branch. This generalized rate increase is accompanied by extensive fine-scale heterogeneity in rates across loci, genomes, and taxa. Our analyses demonstrate the effectiveness and flexibility of trait-free investigations of rate heterogeneity within a model-selection framework, emphasize the importance of explicit tests for signatures of selection prior to invoking selection-related or demography-based explanations for patterns of rate variation, and illustrate some unexpected nuances in the behavior of relaxed clock methods for modeling rate heterogeneity, with implications for our ability to confidently date divergence events. In addition, our data provide strong support for the monophyly of Adiantum, and for the position of Calciphilopteris in the cheilanthoid ferns, two relationships for which convincing support was previously lacking.

  1. Phenomenological approach to precise creep life prediction by means of quantitative evaluation of strain rate acceleration in secondary creep

    NASA Astrophysics Data System (ADS)

    Sato, Hiroyuki; Miyano, Takaya

    2010-07-01

    A method of creep life prediction by means of Strain-Acceleration-Parameter (SAP), α, is presented. The authors show that the shape of creep curve can be characterized by SAP that reflects magnitude of strain-rate change in secondary creep. The SAP-values, α are evaluated on magnesium-aluminium solution hardened alloys. Reconstruction of creep curves by combinations of SAP and minimum-creep rates are successfully performed, and the curves reasonably agree with experiments. The advantage of the proposed method is that the required parameters evaluated from individual creep curves are directly connected with the minimum creep rate. The predicted times-to-failure agree well with that obtained by experiments, and possibility of precise life time prediction by SAP is pronounced.

  2. Cortical porosity exhibits accelerated rate of change in peri- compared with post-menopausal women.

    PubMed

    Burt, L A; Bhatla, J L; Hanley, D A; Boyd, S K

    2017-01-10

    The rate of change in bone density was not different between peri- and post-menopausal women. Differences in rate of change were observed in bone microarchitecture, specifically cortical porosity (Ct.Po), where peri-menopausal women increased +9% per year compared with the +6% per year for post-menopausal women.

  3. SU-E-T-495: Neutron Induced Electronics Failure Rate Analysis for a Single Room Proton Accelerator

    SciTech Connect

    Knutson, N; DeWees, T; Klein, E

    2014-06-01

    Purpose: To determine the failure rate as a function of neutron dose of the range modulator's servo motor controller system (SMCS) while shielded with Borated Polyethylene (BPE) and unshielded in a single room proton accelerator. Methods: Two experimental setups were constructed using two servo motor controllers and two motors. Each SMCS was then placed 30 cm from the end of the plugged proton accelerator applicator. The motor was then turned on and observed from outside of the vault while being irradiated to known neutron doses determined from bubble detector measurements. Anytime the motor deviated from the programmed motion a failure was recorded along with the delivered dose. The experiment was repeated using 9 cm of BPE shielding surrounding the SMCS. Results: Ten SMCS failures were recorded in each experiment. The dose per monitor unit for the unshielded SMCS was 0.0211 mSv/MU and 0.0144 mSv/MU for the shielded SMCS. The mean dose to produce a failure for the unshielded SMCS was 63.5 ± 58.3 mSv versus 17.0 ±12.2 mSv for the shielded. The mean number of MUs between failures were 2297 ± 1891 MU for the unshielded SMCS and 2122 ± 1523 MU for the shielded. A Wilcoxon Signed Ranked test showed the dose between failures were significantly different (P value = 0.044) while the number of MUs between failures were not (P value = 1.000). Statistical analysis determined a SMCS neutron dose of 5.3 mSv produces a 5% chance of failure. Depending on the workload and location of the SMCS, this failure rate could impede clinical workflow. Conclusion: BPE shielding was shown to not reduce the average failure of the SMCS and relocation of the system outside of the accelerator vault was required to lower the failure rate enough to avoid impeding clinical work flow.

  4. Upgrading the ATLAS fast calorimeter simulation

    NASA Astrophysics Data System (ADS)

    Hubacek, Z.; ATLAS Collaboration

    2016-10-01

    Many physics and performance studies with the ATLAS detector at the Large Hadron Collider require very large samples of simulated events, and producing these using the full Geant4 detector simulation is highly CPU intensive. Often, a very detailed detector simulation is not needed, and in these cases fast simulation tools can be used to reduce the calorimeter simulation time. In ATLAS, a fast simulation of the calorimeter systems was developed, called Fast Calorimeter Simulation (FastCaloSim). It provides a parametrized simulation of the particle energy response at the calorimeter read-out cell level. It is interfaced to the standard ATLAS digitization and reconstruction software and can be tuned to data more easily than Geant4. An improved parametrization is being developed, to eventually address shortcomings of the original version. It makes use of statistical techniques such as principal component analysis and a neural network parametrization to optimise the amount of information to store in the ATLAS simulation infrastructure.

  5. CDF End Plug calorimeter Upgrade Project

    SciTech Connect

    Apollinari, G.; de Barbaro, P.; Mishina, M.

    1994-01-01

    We report on the status of the CDF End Plug Upgrade Project. In this project, the CDF calorimeters in the end plug and the forward regions will be replaced by a single scintillator based calorimeter. After an extensive R&D effort on the tile/fiber calorimetry, we have now advanced to a construction phase. We review the results of the R&D leading to the final design of the calorimeters and the development of tooling devised for this project. The quality control program of the production of the electromagnetic and hadronic calorimeters is described. A shower maximum detector for the measurement of the shower centroid and the shower profile of electrons, {gamma} and {pi}{sup 0} has been designed. Its performance requirements, R&D results and mechanical design are discussed.

  6. The BaBar electromagnetic calorimeter

    SciTech Connect

    Stahl, A.

    1997-07-01

    The progress on the design and construction of the BaBar electromagnetic calorimeter including its mechanical structure, the readout system, the mechanical and optical properties of the crystals, and the schedule for the final assembly and testing is summarized.

  7. Electron diffraction using ultrafast electron bunches from a laser-wakefield accelerator at kHz repetition rate

    NASA Astrophysics Data System (ADS)

    He, Z.-H.; Thomas, A. G. R.; Beaurepaire, B.; Nees, J. A.; Hou, B.; Malka, V.; Krushelnick, K.; Faure, J.

    2013-02-01

    We show that electron bunches in the 50-100 keV range can be produced from a laser wakefield accelerator using 10 mJ, 35 fs laser pulses operating at 0.5 kHz. It is shown that using a solenoid magnetic lens, the electron bunch distribution can be shaped. The resulting transverse and longitudinal coherence is suitable for producing diffraction images from a polycrystalline 10 nm aluminum foil. The high repetition rate, the stability of the electron source, and the fact that its uncorrelated bunch duration is below 100 fs make this approach promising for the development of sub-100 fs ultrafast electron diffraction experiments.

  8. Insulin accelerates global and mitochondrial protein synthesis rates in neonatal muscle during sepsis

    Technology Transfer Automated Retrieval System (TEKTRAN)

    In neonatal pigs, sepsis decreases protein synthesis in skeletal muscle by decreasing translation initiation. However, insulin stimulates muscle protein synthesis despite persistent repression of translation initiation signaling. To determine whether the insulin-induced increase in global rates of m...

  9. Transportable high sensitivity small sample radiometric calorimeter

    SciTech Connect

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-12-31

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most {sup 238}Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size.

  10. Rate accelerations in nuclear 18S rDNA of mycoheterotrophic and parasitic angiosperms.

    PubMed

    Lemaire, Benny; Huysmans, Suzy; Smets, Erik; Merckx, Vincent

    2011-09-01

    Rate variation in genes from all three genomes has been observed frequently in plant lineages with a parasitic and mycoheterotrophic mode of life. While the loss of photosynthetic ability leads to a relaxation of evolutionary constraints in genes involved in the photosynthetic apparatus, it remains to be determined how prevalent increased substitution rates are in nuclear DNA of non-photosynthetic angiosperms. In this study we infer rates of molecular evolution of 18S rDNA of all parasitic and mycoheterotorphic plant families (except Lauraceae and Polygalaceae) using relative rate tests. In several holoparasitic and mycoheterotrophic plant lineages extremely high substitution rates are observed compared to other photosynthetic angiosperms. The position and frequency of these substitutions have been identified to understand the mutation dynamics of 18S rRNA in achlorophyllous plants. Despite the presence of significantly elevated substitution rates, very few mutations occur in major functional and structural regions of the small ribosomal molecule, providing evidence that the efficiency of the translational apparatus in non-photosynthetic plants has not been affected.

  11. Surface composition and barium evaporation rate of ``pedigreed'' impregnated tungsten dispenser cathodes during accelerated life testing

    NASA Astrophysics Data System (ADS)

    Tomich, D. H.; Mescher, J. A.; Grant, J. T.

    1987-03-01

    A study has been made of the surface composition and barium evaporation rate of "pedigreed" impregnated tungsten dispenser cathodes. The effect of air exposure on coated cathodes was examined and was found to have no significant effect on barium evaporation rate although in some cases longer reactivation times were required. No changes in surface topography were apparent following air exposure and reactivation. Life testing was done at 100°C above the typical operating temperature for the cathode, where the typical operating temperature was taken to be 950°C for coated cathodes and 1050°C for uncoated cathodes. The cathodes were examined at different stages of life testing, up to 1200 h. Significant decreases in barium evaporation rates were found after as few as 500 h of life testing. After 1000 h the evaporation rate had decreased more than an order of magnitude. Changes in surface composition were also found. The effects of tungsten particle size, used in manufacture of the billet, on barium evaporation rate were also studied but no correlation was found.

  12. Response of the D0 calorimeter to cosmic ray muons

    SciTech Connect

    Kotcher, J.

    1992-10-01

    The D0 Detector at the Fermi National Accelerator Laboratory is a large multipurpose detector facility designed for the study of proton-antiproton collision products at the center-of-mass energy of 2 TeV. It consists of an inner tracking volume, hermetic uranium/liquid argon sampling calorimetry, and an outer 47{pi} muon detector. In preparation for our first collider run, the collaboration organized a Cosmic Ray Commissioning Run, which took place from February--May of 1991. This thesis is a detailed study of the response of the central calorimeter to cosmic ray muons as extracted from data collected during this run. We have compared the shapes of the experimentally-obtained pulse height spectra to the Landau prediction for the ionization loss in a continuous thin absorber in the four electromagnetic and four hadronic layers of the calorimeter, and find good agreement after experimental effects are folded in. We have also determined an absolute energy calibration using two independent methods: one which measures the response of the electronics to a known amount of charge injected at the preamplifiers, and one which uses a carry-over of the calibration from a beam test of central calorimeter modules. Both absolute energy conversion factors agree with one another, within their errors. The calibration determined from the test beam carryover, relevant for use with collider physics data, has an error of 2.3%. We believe that, with further study, a final error of {approx}1% will be achieved. The theory-to-experiment comparison of the peaks (or most probable values) of the muon spectra was used to determine the layer-to-layer consistency of the muon signal. We find that the mean response in the 3 fine hadronic layers is (12 {plus_minus} 2%) higher than that in the 4 electromagnetic layers. These same comparisons have been used to verify the absolute energy conversion factors. The conversion factors work well for the electromagnetic sections.

  13. Amplified Rate Acceleration by Simultaneous Up-Regulation of Multiple Active Sites in an Endo-Functionalized Porous Capsule.

    PubMed

    Kopilevich, Sivil; Müller, Achim; Weinstock, Ira A

    2015-10-14

    Using the hydrolysis of epoxides in water as a model reaction, the effect of multiple active sites on Michaelis-Menten compliant rate accelerations in a porous capsule is demonstrated. The capsule is a water-soluble Ih-symmetry Keplerate-type complex of the form, [{Mo(VI)6O21(H2O)6}12{Mo(V)2O4(L)}30](42-), in which 12 pentagonal "ligands," {(Mo(VI))Mo(VI)5O21(H2O)6}(6-), are coordinated to 30 dimolybdenum sites, {Mo(V)2O4L}(1+) (L = an endohedrally coordinated η(2)-bound carboxylate anion), resulting in 20 Mo9O9 pores. When "up-regulated" by removal of ca. one-third of the blocking ligands, L, an equal number of dimolybdenum sites are activated, and the newly freed-up space allows for encapsulation of nearly twice as many substrate guests, leading to a larger effective molarity (amplification), and an increase in the rate acceleration (k(cat)/k(uncat)) from 16,000 to an enzyme-like value of 182,800.

  14. Lewis Acid Accelerated Aryl Ether Bond Cleavage with Nickel: Orders of Magnitude Rate Enhancement Using AlMe3.

    PubMed

    Kelley, Paul; Edouard, Guy A; Lin, Sibo; Agapie, Theodor

    2016-11-21

    Study of the kinetics of intramolecular aryl ether C-O bond cleavage by Ni was facilitated by access to a family of metal complexes supported by diphosphines with pendant aryl-methyl ethers. The nature of the aryl substituents was found to have little effect on the rate of cleavage. In contrast, soluble Lewis acidic additives accelerate the aryl ether cleavage dramatically. The effect of AlMe3 was studied in detail, and showed an increase in rate by several orders of magnitude. Low temperature NMR spectroscopy studies demonstrate quantitative coordination of ether to Al. From the Lewis acid-bound precursor, the activation parameters for ether cleavage are significantly lower. These findings provide a mechanistic basis for milder catalyst design for the activation of strong bonds.

  15. Accelerating the initial rate of hydrolysis of methyl parathion with laser excitation using monolayer protected 10 nm Au nanoparticles capped with a Cu(bpy) catalyst.

    PubMed

    Trammell, Scott A; Nita, Rafaela; Moore, Martin; Zabetakis, Dan; Chang, Eddie; Knight, D Andrew

    2012-04-28

    Using a low power green laser, we have demonstrated a rate acceleration of ~2-fold for the hydrolysis of methyl parathion by irradiating the plasmon absorption band of Au nanoparticles capped with a Cu(bpy) catalyst.

  16. Selective sinoatrial node optical mapping to investigate the mechanism of sinus rate acceleration

    NASA Astrophysics Data System (ADS)

    Lin, Shien-Fong; Shinohara, Tetsuji; Joung, Boyoung; Chen, Peng-Sheng

    2011-03-01

    Studies using isolated sinoatrial node (SAN) cells indicate that rhythmic spontaneous sarcoplasmic reticulum Ca release (Ca clock) plays an important role in SAN automaticity. However, it is difficult to translate these findings into intact SAN because the SAN is embedded in the right atrium (RA). Cross contamination of the optical signals between SAN and RA prevented the definitive testing of Ca clock hypothesis in intact SAN. We use a novel approach to selectively map intact SAN to examine the Ca clock function in intact RA. We simultaneously mapped intracellular Ca (Cai) and membrane potential (Vm) in 7 isolated, Langendorff perfused normal canine RA. Electrical conduction from the SAN to RA was inhibited with high potassium (10 mmol/L) Tyrode's solution, allowing selective optical mapping of Vm and Cai of the SAN. Isoproterenol (ISO, 0.03 μmol/L) decreased cycle length of the sinus beats from 586+/-17 ms at baseline to 366+/-32 ms, and shifted the leading pacemaker site from the middle or inferior SAN to the superior SAN in all RAs. The Cai upstroke preceded the Vm in the leading pacemaker site by up to 18+/-2 ms. ISO-induced changes to SAN were inhibited by ryanodine (3 μmol/L), but not ZD7288 (3 μmol/L), a selective If blocker. We conclude that a high extracellular potassium concentration results in intermittent SAN-RA conduction block, allowing selective optical mapping of the intact SAN. Acceleration of Ca cycling in the superior SAN underlies the mechanism of sinus tachycardia during sympathetic stimulation.

  17. Monte Carlo simulation of an actual segmented calorimeter: a study of calorimeter performance at high energies

    SciTech Connect

    Gabriel, T.A.; Bishop, B.L.; Goodman, M.S.; Sessoms, A.L.; Eisenstein, B.; Wright, S.C.; Kephart, R.D.

    1981-01-01

    The calculated responses including energy resolution, angular resolution, and spatial energy deposition of a segmented iron and liquid-argon calorimeter to incident pions in the energy range of 10- to 250-GeV are presented. Experimental data for this calorimeter have been obtained in the 10- to 40- GeV energy range and these results compare favorably with the calculated data.

  18. Ancient dates or accelerated rates? Morphological clocks and the antiquity of placental mammals.

    PubMed

    Beck, Robin M D; Lee, Michael S Y

    2014-10-22

    Analyses of a comprehensive morphological character matrix of mammals using 'relaxed' clock models (which simultaneously estimate topology, divergence dates and evolutionary rates), either alone or in combination with an 8.5 kb nuclear sequence dataset, retrieve implausibly ancient, Late Jurassic-Early Cretaceous estimates for the initial diversification of Placentalia (crown-group Eutheria). These dates are much older than all recent molecular and palaeontological estimates. They are recovered using two very different clock models, and regardless of whether the tree topology is freely estimated or constrained using scaffolds to match the current consensus placental phylogeny. This raises the possibility that divergence dates have been overestimated in previous analyses that have applied such clock models to morphological and total evidence datasets. Enforcing additional age constraints on selected internal divergences results in only a slight reduction of the age of Placentalia. Constraining Placentalia to less than 93.8 Ma, congruent with recent molecular estimates, does not require major changes in morphological or molecular evolutionary rates. Even constraining Placentalia to less than 66 Ma to match the 'explosive' palaeontological model results in only a 10- to 20-fold increase in maximum evolutionary rate for morphology, and fivefold for molecules. The large discrepancies between clock- and fossil-based estimates for divergence dates might therefore be attributable to relatively small changes in evolutionary rates through time, although other explanations (such as overly simplistic models of morphological evolution) need to be investigated. Conversely, dates inferred using relaxed clock models (especially with discrete morphological data and MrBayes) should be treated cautiously, as relatively minor deviations in rate patterns can generate large effects on estimated divergence dates.

  19. Ancient dates or accelerated rates? Morphological clocks and the antiquity of placental mammals

    PubMed Central

    Beck, Robin M. D.; Lee, Michael S. Y.

    2014-01-01

    Analyses of a comprehensive morphological character matrix of mammals using ‘relaxed’ clock models (which simultaneously estimate topology, divergence dates and evolutionary rates), either alone or in combination with an 8.5 kb nuclear sequence dataset, retrieve implausibly ancient, Late Jurassic–Early Cretaceous estimates for the initial diversification of Placentalia (crown-group Eutheria). These dates are much older than all recent molecular and palaeontological estimates. They are recovered using two very different clock models, and regardless of whether the tree topology is freely estimated or constrained using scaffolds to match the current consensus placental phylogeny. This raises the possibility that divergence dates have been overestimated in previous analyses that have applied such clock models to morphological and total evidence datasets. Enforcing additional age constraints on selected internal divergences results in only a slight reduction of the age of Placentalia. Constraining Placentalia to less than 93.8 Ma, congruent with recent molecular estimates, does not require major changes in morphological or molecular evolutionary rates. Even constraining Placentalia to less than 66 Ma to match the ‘explosive’ palaeontological model results in only a 10- to 20-fold increase in maximum evolutionary rate for morphology, and fivefold for molecules. The large discrepancies between clock- and fossil-based estimates for divergence dates might therefore be attributable to relatively small changes in evolutionary rates through time, although other explanations (such as overly simplistic models of morphological evolution) need to be investigated. Conversely, dates inferred using relaxed clock models (especially with discrete morphological data and MrBayes) should be treated cautiously, as relatively minor deviations in rate patterns can generate large effects on estimated divergence dates. PMID:25165770

  20. UVB Exposure Does Not Accelerate Rates of Litter Decomposition in a Semiarid Riparian Ecosystem

    NASA Astrophysics Data System (ADS)

    Uselman, S. M.; Snyder, K. A.; Blank, R. R.; Jones, T. J.

    2010-12-01

    Aboveground litter decomposition is controlled mainly by substrate quality and climate factors across terrestrial ecosystems, but photodegradation from exposure to high-intensity ultraviolet-B (UVB) radiation may also be important in arid and semi-arid environments. We investigated the interactive effects of UVB exposure and litter quality on decomposition in a Tamarix-invaded riparian ecosystem during the establishment of an insect biological control agent in northern Nevada. Feeding by the northern tamarisk beetle (Diorhabda carinulata) on Tamarix spp. trees leads to altered leaf litter quality and increased exposure to solar UVB radiation from canopy opening. In addition, we examined the dynamics of litter decomposition of the invasive exotic Lepidium latifolium, because it is well-situated to invade beetle-infested Tamarix sites. Three leaf litter types (natural Tamarix, beetle-affected Tamarix, and L. latifolium) differing in substrate quality were decomposed in litterbags for one year in the field. Litterbags were subjected to one of three treatments: (1) Ambient UVB or (2) Reduced UVB (where UVB was manipulated by using clear plastic films that transmit or block UVB), and (3) No Cover (a control used to test for the effect of using the plastic films, i.e. a cover effect). Results showed a large cover effect on rates of decomposition and nutrient release, and our findings suggested that frequent cycles of freeze-thaw, and possibly rainfall intensity, influenced decomposition at this site. Contrary to our expectations, greater UVB exposure did not result in faster rates of decomposition. Greater UVB exposure resulted in decreased rates of decomposition and P release for the lower quality litter and no change in rates of decomposition and nutrient release for the two higher quality litter types, possibly due to a negative effect of UVB on soil microbes. Among litter types, rates of decomposition and net release of N and P followed this ranking: L. latifolium

  1. Isolation of Hox Cluster Genes from Insects Reveals an Accelerated Sequence Evolution Rate

    PubMed Central

    Hadrys, Heike; Simon, Sabrina; Kaune, Barbara; Schmitt, Oliver; Schöner, Anja; Jakob, Wolfgang; Schierwater, Bernd

    2012-01-01

    Among gene families it is the Hox genes and among metazoan animals it is the insects (Hexapoda) that have attracted particular attention for studying the evolution of development. Surprisingly though, no Hox genes have been isolated from 26 out of 35 insect orders yet, and the existing sequences derive mainly from only two orders (61% from Hymenoptera and 22% from Diptera). We have designed insect specific primers and isolated 37 new partial homeobox sequences of Hox cluster genes (lab, pb, Hox3, ftz, Antp, Scr, abd-a, Abd-B, Dfd, and Ubx) from six insect orders, which are crucial to insect phylogenetics. These new gene sequences provide a first step towards comparative Hox gene studies in insects. Furthermore, comparative distance analyses of homeobox sequences reveal a correlation between gene divergence rate and species radiation success with insects showing the highest rate of homeobox sequence evolution. PMID:22685537

  2. Particle Rate and Host Accelerator Beam Loss on the MICE Experiment

    SciTech Connect

    Dobbs, Adam James

    2011-10-01

    A study is presented of particle rates in the MICE Muon Beamline and their relationship to beam loss produced in ISIS. A brief overview of neutrino physics is presented, together with a discussion on the Neutrino Factory as a motivation for MICE. An overview of MICE itself is then presented, highlighting the need for a systematic understanding of the relationship between the MICE target parameters, ISIS beam loss, and MICE particle rate. The variation of beam loss with target depth is examined and observed to be non-linear. The variation of beam loss with respect to the target dip time in the ISIS cycle is examined and observed to be approximately linear for dip times between 11.1 ms and 12.6 ms after ISIS injection, before tailing at earlier dip times. The variation of beam loss with particle rate is also observed to follow an approximately linear relationship from 0.05 V.ms to 4.7 V.ms beam loss, with a further strong indication that this continues up to 7.1 V.ms. Particle identification using time-of-flight data is used to give an insight into the relative abundances of each particle species present in the MICE beam. Estimates of muon rate are then produced as a function of beam loss. At a level of 2 V.ms beam loss ~10.9 muons per spill for a 3.2 ms spill with negative π → μ optics, and ~31.1 muons per 1 ms spill with positive π → μ optics are observed. Simulations using the ORBIT particle tracking code of the beam loss distributions around the ISIS ring, caused by the MICE target, are also presented and the implications for MICE running discussed.

  3. Exposure of human megakaryocytes to high shear rates accelerates platelet production.

    PubMed

    Dunois-Lardé, Claire; Capron, Claude; Fichelson, Serge; Bauer, Thomas; Cramer-Bordé, Elisabeth; Baruch, Dominique

    2009-08-27

    Platelets originate from megakaryocytes (MKs) by cytoplasmic elongation into proplatelets. Direct platelet release is not seen in bone marrow hematopoietic islands. It was suggested that proplatelet fragmentation into platelets can occur intravascularly, yet evidence of its dependence on hydrodynamic forces is missing. Therefore, we investigated whether platelet production from MKs could be up-regulated by circulatory forces. Human mature MKs were perfused at a high shear rate on von Willebrand factor. Cells were observed in real time by videomicroscopy, and by confocal and electron microscopy after fixation. Dramatic cellular modifications followed exposure to high shear rates: 30% to 45% adherent MKs were converted into proplatelets and released platelets within 20 minutes, contrary to static conditions that required several hours, often without platelet release. Tubulin was present in elongated proplatelets and platelets, thus ruling out membrane tethers. By using inhibitors, we demonstrated the fundamental roles of microtubule assembly and MK receptor GPIb. Secretory granules were present along the proplatelet shafts and in shed platelets, as shown by P-selectin labeling. Platelets generated in vitro were functional since they responded to thrombin by P-selectin expression and cytoskeletal reorganization. In conclusion, MK exposure to high shear rates promotes platelet production via GPIb, depending on microtubule assembly and elongation.

  4. Hillslope-channel coupling in a steep Hawaiian catchment accelerates erosion rates over 100-fold

    NASA Astrophysics Data System (ADS)

    Stock, J. D.; Hanshaw, M. N.; Rosener, M.; Schmidt, K. M.; Brooks, B. A.; Tribble, G.; Jacobi, J.

    2009-12-01

    In tropical watersheds, hillslope changes are producing increasing amounts of fine sediment that can be quickly carried to reefs by channels. Suspended sediment concentrations off the reefs of Molokai, Hawaii, chronically exceed a toxic level of 10 mg/L, threatening reef ecosystems. We hypothesize that historic conversion of watersheds from soil creep to overland flow erosion increased both magnitude and frequency of sediment flooding adjacent reefs. We combined surficial and ecological mapping, hillslope and stream gages, and novel sensors to locate, quantify and model the generation of fine sediments polluting the Molokai reef. Ecological and geomorphic mapping from LiDAR and multi-spectral imagery located a subset of overland flow areas with vegetation cover below a threshold value preventing erosion. Here, feral goat grazing exposed cohesive volcanic soils whose low matrix hydraulic conductivities (1-20 mm/hour) promote Horton overland flow erosion. We instrumented steep, barren hillslopes with soil moisture sensors, overland flow meters, Parshall flumes, ISCO sediment samplers, and a rain gage and conducted repeat Tripod LiDAR and infiltration tests. To characterize soil resistance here and elsewhere to overland flow erosion, we deployed a Cohesive Strength Meter (CSM) to simulate the stresses of flowing water. At the 13.5 km 2 watershed mouth we used a USGS stream gage and ISCO sediment sampler to estimate total load. Over 2 years, storms triggered overland flow during rainfall intensities above 10-15 mm/hr. Overland flow meters indicate such flows can be up to 3 cm deep, with a tendency to deepen downslope. CSM tests indicate that these depths are insufficient to erode soils where vegetation is dense, but far above threshold values of 2-3 mm depth for bare soil erosion. Sediment ratings curves for both hillslope and downstream catchment gages show strong clock-wise hysteresis during the first intense storms in the Fall, becoming linear later in the rainy

  5. Monte Carlo Simulation of Massive Absorbers for Cryogenic Calorimeters

    SciTech Connect

    Brandt, D.; Asai, M.; Brink, P.L.; Cabrera, B.; Silva, E.do Couto e; Kelsey, M.; Leman, S.W.; McArthy, K.; Resch, R.; Wright, D.; Figueroa-Feliciano, E.; /MIT

    2012-06-12

    There is a growing interest in cryogenic calorimeters with macroscopic absorbers for applications such as dark matter direct detection and rare event search experiments. The physics of energy transport in calorimeters with absorber masses exceeding several grams is made complex by the anisotropic nature of the absorber crystals as well as the changing mean free paths as phonons decay to progressively lower energies. We present a Monte Carlo model capable of simulating anisotropic phonon transport in cryogenic crystals. We have initiated the validation process and discuss the level of agreement between our simulation and experimental results reported in the literature, focusing on heat pulse propagation in germanium. The simulation framework is implemented using Geant4, a toolkit originally developed for high-energy physics Monte Carlo simulations. Geant4 has also been used for nuclear and accelerator physics, and applications in medical and space sciences. We believe that our current work may open up new avenues for applications in material science and condensed matter physics.

  6. Simulation of Energy Response of the ATIC Calorimeter

    NASA Technical Reports Server (NTRS)

    Batkov, K. E.; Adams, J. H., Jr.; Ahn, H. S.; Bashindzhagyan, G. L.; Case, G.; Christl, M.; Chang, J.; Fazely, A. R.; Ganel, O.; Granger, D.; Six, N. Frank (Technical Monitor)

    2002-01-01

    ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CR particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2001. The ATIC flight collected approximately 25 million events. For reconstruction of primary spectra from spectra of energy deposits measured in the experiment, correlations between kinetic energy of a primary particle E(sub kin) and energy deposit in the calorimeter E(sub d) should be known. For this purpose, simulations of energy response of the calorimeter on energy spectra of different nuclei were done. The simulations were performed by GEANT-3.21 code with QGSM generator for nucleus - nucleus interactions. The incident flux was taken as isotropic in the ATIC aperture. Primary spectra power-law by momentum were used as inputs according to standard models of cosmic ray acceleration. These spectra become power-law by kinetic energy at E(sub kin) higher than approx.20Mc(sup 2), where M is primary nucleus mass. It should be noted that energy deposit spectra measured by ATIC illustrate similar behavior. Distributions of ratio E(sub kin)/E(sub d) are presented for different energy deposits and for a set of primaries. For power-law regions of energy spectra at E(sub d)> or equal to 20Mc(sup 2) the obtained mean value of E(sub kin)/E(sub d) increases from approx.2.4 for protons to approx.3.1 for iron, while rms/ decreases from 50% for protons to about 15% for iron. These values were obtained for the spectral index gamma=1.6

  7. Study of requirements and performances of the electromagnetic calorimeter for the Mu2e experiment at Fermilab

    SciTech Connect

    Soleti, S.

    2015-06-15

    In this thesis we discuss the simulation and tests carried out for the optimization and design of the electromagnetic calorimeter for the Mu2e (Muon to electron conversion) experiment, which is a proposed experiment part of the Muon Campus hosted at Fermi National Accelerator Laboratory (FNAL) in Batavia, United States.

  8. MRI-based brain atrophy rates in ADNI phase 2: acceleration and enrichment considerations for clinical trials.

    PubMed

    Hua, Xue; Ching, Christopher R K; Mezher, Adam; Gutman, Boris A; Hibar, Derrek P; Bhatt, Priya; Leow, Alex D; Jack, Clifford R; Bernstein, Matt A; Weiner, Michael W; Thompson, Paul M

    2016-01-01

    The goal of this work was to assess statistical power to detect treatment effects in Alzheimer's disease (AD) clinical trials using magnetic resonance imaging (MRI)-derived brain biomarkers. We used unbiased tensor-based morphometry (TBM) to analyze n = 5,738 scans, from Alzheimer's Disease Neuroimaging Initiative 2 participants scanned with both accelerated and nonaccelerated T1-weighted MRI at 3T. The study cohort included 198 healthy controls, 111 participants with significant memory complaint, 182 with early mild cognitive impairment (EMCI) and 177 late mild cognitive impairment (LMCI), and 155 AD patients, scanned at screening and 3, 6, 12, and 24 months. The statistical power to track brain change in TBM-based imaging biomarkers depends on the interscan interval, disease stage, and methods used to extract numerical summaries. To achieve reasonable sample size estimates for potential clinical trials, the minimal scan interval was 6 months for LMCI and AD and 12 months for EMCI. TBM-based imaging biomarkers were not sensitive to MRI scan acceleration, which gave results comparable with nonaccelerated sequences. ApoE status and baseline amyloid-beta positron emission tomography data improved statistical power. Among healthy, EMCI, and LMCI participants, sample size requirements were significantly lower in the amyloid+/ApoE4+ group than for the amyloid-/ApoE4- group. ApoE4 strongly predicted atrophy rates across brain regions most affected by AD, but the remaining 9 of the top 10 AD risk genes offered no added predictive value in this cohort.

  9. Upper bounds for convergence rates of acceleration methods with initial iterations

    NASA Astrophysics Data System (ADS)

    Sidi, Avram; Shapira, Yair

    1998-06-01

    GMRES(n,k), a version of GMRES for the solution of large sparse linear systems, is introduced. A cycle of GMRES(n,k) consists of n Richardson iterations followed by k iterations of GMRES. Such cycles can be repeated until convergence is achieved. The advantage in this approach is in the opportunity to use moderate k, which results in time and memory saving. Because the number of inner products among the vectors of iteration is about k2/2, using a moderate k is particularly attractive on message-passing parallel architectures, where inner products require expensive global communication. The present analysis provides tight upper bounds for the convergence rates of GMRES(n,k) for problems with diagonalizable coefficient matrices whose spectra lie in an ellipse in 0. The advantage of GMRES(n,k) over GMRES(k) is illustrated numerically.

  10. Circulation rate of change: A vortex approach for understanding accelerated inhomogeneous flows through intermediate times

    NASA Astrophysics Data System (ADS)

    Lee, Dong-Kee; Peng, Gaozhu; Zabusky, Norman J.

    2006-09-01

    We present a new simple diagnostic formula, Eq. (4) in this paper, involving a pressure difference, for determining the rate-of-change of total circulation, Γ˙D (within a domain M =1.3), single-mode, inviscid environment with an initially finite-width interfacial transition layer (ITL), and various postshock Atwood numbers, 0.2≤A*≤0.75. We show that for intermediate times (up to t /tM<8.0), Γ˙D/(Γshock/tM), has several consistent behaviors and scaling laws depending on A*. Here Γshock, is the circulation deposited by the initial shock on the region of finite density gradient and tM is the time at which the single mode interfacial midcontour becomes multivalued.

  11. Beam test of a prototype fine-granularity scintillator tile EM calorimeter

    NASA Astrophysics Data System (ADS)

    Sanchez, A. L. C.; Miyata, H.; Nakajima, N.; Ono, H.; Fujii, Y.; Itoh, S.; Kajino, F.; Kanzaki, J.; Kawagoe, K.; Kim, S.; Kishimoto, S.; Matsumoto, T.; Matsunaga, H.; Nagano, A.; Nakamura, R.; Sekiguchi, K.; Takeshita, T.; Uchida, N.; Yamada, Y.; Yamamoto, S.; Yamauchi, S.

    2005-07-01

    We are studying the performance of an electromagnetic calorimeter for the linear collider detector that uses 4 cm×4 cm×1 mm plastic scintillator tiles as active media. To establish fabrication technique we built a thin test module. We then studied the uniformity of the module response as well as its position resolution at a test beam facility at the High-Energy Accelerator Research Organization.

  12. Accelerated Growth Rate and Increased Drought Stress Resilience of the Model Grass Brachypodium distachyon Colonized by Bacillus subtilis B26.

    PubMed

    Gagné-Bourque, François; Mayer, Boris F; Charron, Jean-Benoit; Vali, Hojatollah; Bertrand, Annick; Jabaji, Suha

    2015-01-01

    Plant growth-promoting bacteria (PGB) induce positive effects in plants, for instance, increased growth and reduced abiotic stresses susceptibility. The mechanisms by which these bacteria impact the host plant are numerous, diverse and often specific. Here, we studied the agronomical, molecular and biochemical effects of the endophytic PGB Bacillus subtilis B26 on the full life cycle of Brachypodium distachyon Bd21, an established model species for functional genomics in cereal crops and temperate grasses. Inoculation of Brachypodium with B. subtilis strain B26 increased root and shoot weights, accelerated growth rate and seed yield as compared to control plants. B. subtilis strain B26 efficiently colonized the plant and was recovered from roots, stems and blades as well as seeds of Brachypodium, indicating that the bacterium is able to migrate, spread systemically inside the plant, establish itself in the aerial plant tissues and organs, and is vertically transmitted to seeds. The presence of B. subtilis strain B26 in the seed led to systemic colonization of the next generation of Brachypodium plants. Inoculated Brachypodium seedlings and mature plants exposed to acute and chronic drought stress minimized the phenotypic effect of drought compared to plants not harbouring the bacterium. Protection from the inhibitory effects of drought by the bacterium was linked to upregulation of the drought-response genes, DREB2B-like, DHN3-like and LEA-14-A-like and modulation of the DNA methylation genes, MET1B-like, CMT3-like and DRM2-like, that regulate the process. Additionally, total soluble sugars and starch contents increased in stressed inoculated plants, a biochemical indication of drought tolerance. In conclusion, we show a single inoculation of Brachypodium with a PGB affected the whole growth cycle of the plant, accelerating its growth rates, shortening its vegetative period, and alleviating drought stress effects. These effects are relevant to grasses and cereal

  13. Silicon photomultiplier characterization for the GlueX barrel calorimeter

    SciTech Connect

    F. Barbosa, J.E. McKisson, J. McKisson, Y. Qiang, E. Smith, C. Zorn

    2012-12-01

    GlueX is a new detector being constructed at Jefferson Laboratory to study gluonic excitations and confinement via the detection of exotic meson states. The hermetic detector includes a barrel calorimeter where the photodetectors must operate in a high magnetic field exceeding 0.5 T. After extensive tests with a variety of sensors, the chosen photodetector will be a custom silicon photomultiplier (SiPM) array manufactured by Hamamatsu Corporation. This paper will focus on the characterization of the first 80 production samples of these SiPMs, including dark rate, photodetection efficiency (PDE), crosstalk, response uniformity and radiation tolerance.

  14. Acceleration in the rate of CNS remyelination in lysolecithin-induced demyelination.

    PubMed

    Pavelko, K D; van Engelen, B G; Rodriguez, M

    1998-04-01

    One important therapeutic goal during CNS injury from trauma or demyelinating diseases such as multiple sclerosis is to develop methods to promote remyelination. We tested the hypothesis that spontaneous remyelination in the toxic nonimmune model of lysolecithin-induced demyelination can be enhanced by manipulating the inflammatory response. In PBS-treated SJL/J mice, the number of remyelinating axons per square millimeter of lesion area increased significantly 3 and 5 weeks after lysolecithin injection in the spinal cord. However, methylprednisolone or a monoclonal antibody (mAb), SCH94.03, developed for its ability to promote remyelination in the Theiler's virus murine model of demyelination, further increased the number of remyelinating axons per lesion area at 3 weeks by a factor of 2.6 and 1.9, respectively, but did not increase the ratio of myelin sheath thickness to axon diameter or the number of cells incorporating tritiated thymidine in the lesion. After 3 weeks, the number of remyelinating axons in the methylprednisolone or mAb SCH94.03 treatment groups was similar to the spontaneous remyelination in the 5 week PBS control-treated group, indicating that these treatments promoted remyelination by increasing its rate rather than its extent. To address a mechanism for promoting remyelination, through an effect on scavenger function, we assessed morphometrically the number of macrophages in lesions after methylprednisolone and mAb SCH94.03 treatment. Methylprednisolone reduced the number of macrophages, but SCH94.03 did not, although both enhanced remyelination. This study supports the hypothesis that even in toxic nonprimary immune demyelination, manipulating the inflammatory response is a benefit in myelin repair.

  15. Wakefield-acceleration of relativistic electrons with few-cycle laser pulses at kHz-repetition-rate

    NASA Astrophysics Data System (ADS)

    Guenot, Diego; Gustas, Dominykas; Vernier, Aline; Boehle, Frederik; Beaurepaire, Benoit; Lopez-Martens, Rodrigo; Faure, Jerome; Appli Team

    2016-10-01

    The generation of relativistic electron beams using laser wakefield acceleration has become a standard technique, providing low emittance electron bunches with femtosecond durations. However, this technique usually requires multi-ten-terawatt lasers and is thus limited to low repetition-rate (typically 10 Hz or less). We have recently demonstrated the generation of few MeV electrons using 2.5-mJ, 4-fs, 1-kHz repetition-rate laser pulses, focused to relativistic intensity onto a gas jet with electron density 1020 cm-3. We have investigated the influence of the pulse duration, the gas density. We demonstrated that an electron beam with a charge in the range of 10-fC/shot, with a divergence of 20-mrad and a peaked spectrum with energies between 2 and 4 MeV can be generated at kHz repetition-rate. These results confirm the possibility of using few-cycle laser pulses with very low energy for exciting wakefields in the bubble regime and for trapping electrons, as predicted by PIC simulations. This kHz electron source is ideally suited for performing electron diffraction experiments with very high temporal resolution. Our results also open the way to other applications, such as the generation of a kHz ultrafast X-ray source. ERC femtoelec.

  16. Application of Overall Dynamic Body Acceleration as a Proxy for Estimating the Energy Expenditure of Grazing Farm Animals: Relationship with Heart Rate

    PubMed Central

    Miwa, Masafumi; Oishi, Kazato; Nakagawa, Yasuhiro; Maeno, Hiromichi; Anzai, Hiroki; Kumagai, Hajime; Okano, Kanji; Tobioka, Hisaya; Hirooka, Hiroyuki

    2015-01-01

    Estimating the energy expenditure of farm animals at pasture is important for efficient animal management. In recent years, an alternative technique for estimating energy expenditure by measuring body acceleration has been widely performed in wildlife and human studies, but the availability of the technique in farm animals has not yet been examined. In the present study, we tested the potential use of an acceleration index, overall dynamic body acceleration (ODBA), as a new proxy for estimating the energy expenditure of grazing farm animals (cattle, goats and sheep) at pasture with the simultaneous evaluation of a conventional proxy, heart rate. Body accelerations in three axes and heart rate for cows (n = 8, two breeds), goats (n = 6) and sheep (n = 5) were recorded, and the effect of ODBA calculated from the body accelerations on heart rate was analyzed. In addition, the effects of the two other activity indices, the number of steps and vectorial dynamic body acceleration (VeDBA), on heart rate were also investigated. The results of the comparison among three activity indices indicated that ODBA was the best predictor for heart rate. Although the relationship between ODBA and heart rate was different between the groups of species and breeds and between individuals (P<0.01), the difference could be explained by different body weights; a common equation could be established by correcting the body weights (M: kg): heart rate (beats/min) = 147.263∙M-0.141 + 889.640∙M-0.179∙ODBA (g). Combining this equation with the previously reported energy expenditure per heartbeat, we estimated the energy expenditure of the tested animals, and the results indicated that ODBA is a good proxy for estimating the energy expenditure of grazing farm animals across species and breeds. The utility and simplicity of the procedure with acceleration loggers could make the accelerometry technique a worthwhile option in field research and commercial farm use. PMID:26030931

  17. Application of overall dynamic body acceleration as a proxy for estimating the energy expenditure of grazing farm animals: relationship with heart rate.

    PubMed

    Miwa, Masafumi; Oishi, Kazato; Nakagawa, Yasuhiro; Maeno, Hiromichi; Anzai, Hiroki; Kumagai, Hajime; Okano, Kanji; Tobioka, Hisaya; Hirooka, Hiroyuki

    2015-01-01

    Estimating the energy expenditure of farm animals at pasture is important for efficient animal management. In recent years, an alternative technique for estimating energy expenditure by measuring body acceleration has been widely performed in wildlife and human studies, but the availability of the technique in farm animals has not yet been examined. In the present study, we tested the potential use of an acceleration index, overall dynamic body acceleration (ODBA), as a new proxy for estimating the energy expenditure of grazing farm animals (cattle, goats and sheep) at pasture with the simultaneous evaluation of a conventional proxy, heart rate. Body accelerations in three axes and heart rate for cows (n = 8, two breeds), goats (n = 6) and sheep (n = 5) were recorded, and the effect of ODBA calculated from the body accelerations on heart rate was analyzed. In addition, the effects of the two other activity indices, the number of steps and vectorial dynamic body acceleration (VeDBA), on heart rate were also investigated. The results of the comparison among three activity indices indicated that ODBA was the best predictor for heart rate. Although the relationship between ODBA and heart rate was different between the groups of species and breeds and between individuals (P<0.01), the difference could be explained by different body weights; a common equation could be established by correcting the body weights (M: kg): heart rate (beats/min) = 147.263∙M-0.141 + 889.640∙M-0.179∙ODBA (g). Combining this equation with the previously reported energy expenditure per heartbeat, we estimated the energy expenditure of the tested animals, and the results indicated that ODBA is a good proxy for estimating the energy expenditure of grazing farm animals across species and breeds. The utility and simplicity of the procedure with acceleration loggers could make the accelerometry technique a worthwhile option in field research and commercial farm use.

  18. Vacuum-jacketed hydrofluoric acid solution calorimeter

    USGS Publications Warehouse

    Robie, R.A.

    1965-01-01

    A vacuum-jacketed metal calorimeter for determining heats of solution in aqueous HF was constructed. The reaction vessel was made of copper and was heavily gold plated. The calorimeter has a cooling constant of 0.6 cal-deg -1-min-1, approximately 1/4 that of the air-jacketed calorimeters most commonly used with HF. It reaches equilibrium within 10 min after turning off the heater current. Measurements of the heat of solution of reagent grade KCl(-100 mesh dried 2 h at 200??C) at a mole ratio of 1 KCl to 200 H2O gave ??H = 4198??11 cal at 25??C. ?? 1965 The American Institute of Physics.

  19. Temperature Effects in the ATIC BGO Calorimeter

    NASA Technical Reports Server (NTRS)

    Isbert, J.; Adams, J. H.; Ahn, H.; Bashindzhagyan, G.; Batkov, K.; Chang, J.; Christl, M. J.; Fazely, A.; Ganel, O.; Gunasigha, R.

    2006-01-01

    The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment contains a segmented calorimeter composed of 320 individual BGO crystals (18 radiation lengths deep) to determine the particle energy. Like all inorganic scintillation crystals the light output of BGO depends not only on the energy deposited by particles but also on the temperature of the crystal. ATIC had successful flights in 2000/2001 and 2002/2003 from McMurdo, Antarctica. The temperature of balloon instruments varies during their flights at altitude due to sun angle variations and differences in albedo from the ground and is monitored and recorded. In order to determine the temperature sensitivity of the ATIC calorimeter it was temperature cycled in the thermal vacuum chamber at the CSBF in Palestine, TX. The temperature dependence is derived from the pulse height response to cosmic ray muons at various temperatures.

  20. Influence of Catalysis and Oxidation on Slug Calorimeter Measurements in Arc Jets

    NASA Technical Reports Server (NTRS)

    Nawaz, Anuscheh; Driver, Dave; TerrazasSalinas, Imelda

    2012-01-01

    Arc jet tests play a critical role in the characterization and certification of thermal protection materials and systems (TPS). The results from these arc jet tests feed directly into computational models of material response and aerothermodynamics to predict the performance of the TPS in flight. Thus the precise knowledge of the plasma environment to which the test material is subjected, is invaluable. As one of the environmental parameters, the heat flux is commonly measured. The measured heat flux is used to determine the plasma enthalpy through analytical or computational models. At NASA Ames Research Center (ARC), slug calorimeters of a geometrically similar body to the test article are routinely used to determine the heat flux. A slug calorimeter is a thermal capacitance-type calorimeter that uses the temperature rise in a thermally insulated slug to determine the heat transfer rate, see Figure 1(left). Current best practices for measuring the heat flux with a slug calorimeter are described in ASTM E457 - 96. Both the calorimeter body and slug are made of Oxygen Free High Conductivity Copper, and are cleaned before each run.

  1. Central Calorimeter Thermal Gradient Module Connection Analysis

    SciTech Connect

    Rudland, D.L.; /Fermilab

    1987-08-07

    Two 20 kW condensing and one 10 kW steady state cooling coils will be used to cool and condense gaseous argon in the Central Calorimeter (CC) Cryostat. Since this cool down (300K to 90K) will inevitably cause shrinkage in the modules contained inside the cryostat, the connections between the modules have to be designed to withstand the increase in forces and moments induced by this contraction. This paper presents finite element analysis (ANSYS{reg_sign}) results to aid in the design or modification of the Central Calorimeter module connections.

  2. Precision Crystal Calorimeters in High Energy Physics

    ScienceCinema

    Ren-Yuan Zhu

    2016-07-12

    Precision crystal calorimeters traditionally play an important role in high energy physics experiments. In the last two decades, it faces a challenge to maintain its precision in a hostile radiation environment. This paper reviews the performance of crystal calorimeters constructed for high energy physics experiments and the progress achieved in understanding crystal’s radiation damage as well as in developing high quality scintillating crystals for particle physics. Potential applications of new generation scintillating crystals of high density and high light yield, such as LSO and LYSO, in particle physics experiments is also discussed.

  3. Photodetectors for the CMS hadron calorimeters

    NASA Astrophysics Data System (ADS)

    Elias, J. E.; CMS Hadron Calorimeter Readout Group

    1997-02-01

    Hadronic energy measurements in the central and end cap regions of the Compact Muon Solenoid (CMS) detector will be made using sampling calorimeter techniques with plastic scintillator tiles as the sensitive layers. Plastic fibers doped with wavelength shifting fluors embedded in each tile are used to extract the scintillation light. Clear plastic wave guide fibers carry the shifted light to photodetectors located on the outer surface of the calorimeter structure. Environmental constraints and physics performance requirements for these photodetectors are presented. Candidate photodetector technologies are discussed, and the hybrid photomultiplier tube technology is identified as most promising.

  4. Dual-rate-loop control based on disturbance observer of angular acceleration for a three-axis aerial inertially stabilized platform.

    PubMed

    Zhou, Xiangyang; Jia, Yuan; Zhao, Qiang; Cai, Tongtong

    2016-07-01

    This paper presents a dual-rate-loop control method based on disturbance observer (DOB) of angular acceleration for a three-axis ISP for aerial remote sensing applications, by which the control accuracy and stabilization of ISP are improved obviously. In stabilization loop of ISP, a dual-rate-loop strategy is designed through constituting inner rate loop and the outer rate loop, by which the capability of disturbance rejection is advanced. Further, a DOB-based on angular acceleration is proposed to attenuate the influences of the main disturbances on stabilization accuracy. Particularly, an information fusion method is suggested to obtain accurate angular acceleration in DOB design, which is the key for the disturbance compensation. The proposed methods are theoretically analyzed and experimentally validated to illustrate the effectiveness.

  5. Effects of Sled Towing on Peak Force, the Rate of Force Development and Sprint Performance During the Acceleration Phase.

    PubMed

    Martínez-Valencia, María Asunción; Romero-Arenas, Salvador; Elvira, José L L; González-Ravé, José María; Navarro-Valdivielso, Fernando; Alcaraz, Pedro E

    2015-06-27

    Resisted sprint training is believed to increase strength specific to sprinting. Therefore, the knowledge of force output in these tasks is essential. The aim of this study was to analyze the effect of sled towing (10%, 15% and 20% of body mass (Bm)) on sprint performance and force production during the acceleration phase. Twenty-three young experienced sprinters (17 men and 6 women; men = 17.9 ± 3.3 years, 1.79 ± 0.06 m and 69.4 ± 6.1 kg; women = 17.2 ± 1.7 years, 1.65 ± 0.04 m and 56.6 ± 2.3 kg) performed four 30 m sprints from a crouch start. Sprint times in 20 and 30 m sprint, peak force (Fpeak), a peak rate of force development (RFDpeak) and time to RFD (TRFD) in first step were recorded. Repeated-measures ANOVA showed significant increases (p ≤ 0.001) in sprint times (20 and 30 m sprint) for each resisted condition as compared to the unloaded condition. The RFDpeak increased significantly when a load increased (3129.4 ± 894.6 N·s-1, p ≤ 0.05 and 3892.4 ± 1377.9 N·s-1, p ≤ 0.01). Otherwise, no significant increases were found in Fpeak and TRFD. The RFD determines the force that can be generated in the early phase of muscle contraction, and it has been considered a factor that influences performance of force-velocity tasks. The use of a load up to 20% Bm might provide a training stimulus in young sprinters to improve the RFDpeak during the sprint start, and thus, early acceleration.

  6. Effects of Sled Towing on Peak Force, the Rate of Force Development and Sprint Performance During the Acceleration Phase

    PubMed Central

    Martínez-Valencia, María Asunción; Romero-Arenas, Salvador; Elvira, José L.L.; González-Ravé, José María; Navarro-Valdivielso, Fernando; Alcaraz, Pedro E.

    2015-01-01

    Resisted sprint training is believed to increase strength specific to sprinting. Therefore, the knowledge of force output in these tasks is essential. The aim of this study was to analyze the effect of sled towing (10%, 15% and 20% of body mass (Bm)) on sprint performance and force production during the acceleration phase. Twenty-three young experienced sprinters (17 men and 6 women; men = 17.9 ± 3.3 years, 1.79 ± 0.06 m and 69.4 ± 6.1 kg; women = 17.2 ± 1.7 years, 1.65 ± 0.04 m and 56.6 ± 2.3 kg) performed four 30 m sprints from a crouch start. Sprint times in 20 and 30 m sprint, peak force (Fpeak), a peak rate of force development (RFDpeak) and time to RFD (TRFD) in first step were recorded. Repeated-measures ANOVA showed significant increases (p ≤ 0.001) in sprint times (20 and 30 m sprint) for each resisted condition as compared to the unloaded condition. The RFDpeak increased significantly when a load increased (3129.4 ± 894.6 N·s−1, p ≤ 0.05 and 3892.4 ± 1377.9 N·s−1, p ≤ 0.01). Otherwise, no significant increases were found in Fpeak and TRFD. The RFD determines the force that can be generated in the early phase of muscle contraction, and it has been considered a factor that influences performance of force-velocity tasks. The use of a load up to 20% Bm might provide a training stimulus in young sprinters to improve the RFDpeak during the sprint start, and thus, early acceleration. PMID:26240657

  7. Two-Body Orbit Expansion Due to Time-Dependent Relative Acceleration Rate of the Cosmological Scale Factor

    NASA Astrophysics Data System (ADS)

    Iorio, Lorenzo

    2014-01-01

    By phenomenologically assuming a slow temporal variation of the percent acceleration rate S̈S -1 of the cosmic scale factor S(t), it is shown that the orbit of a local binary undergoes a secular expansion. To first order in the power expansion of S̈S -1 around the present epoch t0, a non-vanishing shift per orbit (Δr) of the two-body relative distance r occurs for eccentric trajectories. A general relativistic expression, which turns out to be cubic in the Hubble parameter H0 at the present epoch, is explicitly calculated for it in the case of matter-dominated epochs with Dark Energy. For a highly eccentric Oort comet orbit with period Pb ≈ 31 Myr, the general relativistic distance shift per orbit turns out to be of the order of (Δr) ≈ 70 km. For the Large Magellanic Cloud, assumed on a bound elliptic orbit around the Milky Way, the shift per orbit is of the order of (Δr) ≈ 2-4 pc. Our result has a general validity since it holds in any cosmological model admitting the Hubble law and a slowly varying S̈S-1(t). More generally, it is valid for an arbitrary Hooke-like extra-acceleration whose "elastic" parameter κ is slowly time-dependent, irrespectively of the physical mechanism which may lead to it. The coefficient κ1 of the first-order term of the power expansion of κ(t) can be preliminarily constrained in a model-independent way down to a κ1 ≤ 2 x 10-13 year-3 level from latest Solar System's planetary observations. The radial velocities of the double lined spectroscopic binary ALPHA Cen AB yield κ1 ≤ 10-8 year-3.

  8. Mimosoid legume plastome evolution: IR expansion, tandem repeat expansions, and accelerated rate of evolution in clpP.

    PubMed

    Dugas, Diana V; Hernandez, David; Koenen, Erik J M; Schwarz, Erika; Straub, Shannon; Hughes, Colin E; Jansen, Robert K; Nageswara-Rao, Madhugiri; Staats, Martijn; Trujillo, Joshua T; Hajrah, Nahid H; Alharbi, Njud S; Al-Malki, Abdulrahman L; Sabir, Jamal S M; Bailey, C Donovan

    2015-11-23

    The Leguminosae has emerged as a model for studying angiosperm plastome evolution because of its striking diversity of structural rearrangements and sequence variation. However, most of what is known about legume plastomes comes from few genera representing a subset of lineages in subfamily Papilionoideae. We investigate plastome evolution in subfamily Mimosoideae based on two newly sequenced plastomes (Inga and Leucaena) and two recently published plastomes (Acacia and Prosopis), and discuss the results in the context of other legume and rosid plastid genomes. Mimosoid plastomes have a typical angiosperm gene content and general organization as well as a generally slow rate of protein coding gene evolution, but they are the largest known among legumes. The increased length results from tandem repeat expansions and an unusual 13 kb IR-SSC boundary shift in Acacia and Inga. Mimosoid plastomes harbor additional interesting features, including loss of clpP intron1 in Inga, accelerated rates of evolution in clpP for Acacia and Inga, and dN/dS ratios consistent with neutral and positive selection for several genes. These new plastomes and results provide important resources for legume comparative genomics, plant breeding, and plastid genetic engineering, while shedding further light on the complexity of plastome evolution in legumes and angiosperms.

  9. Oscillations and accelerations of ice crystal growth rates in microgravity in presence of antifreeze glycoprotein impurity in supercooled water.

    PubMed

    Furukawa, Yoshinori; Nagashima, Ken; Nakatsubo, Shun-Ichi; Yoshizaki, Izumi; Tamaru, Haruka; Shimaoka, Taro; Sone, Takehiko; Yokoyama, Etsuro; Zepeda, Salvador; Terasawa, Takanori; Asakawa, Harutoshi; Murata, Ken-Ichiro; Sazaki, Gen

    2017-03-06

    The free growth of ice crystals in supercooled bulk water containing an impurity of glycoprotein, a bio-macromolecule that functions as 'antifreeze' in living organisms in a subzero environment, was observed under microgravity conditions on the International Space Station. We observed the acceleration and oscillation of the normal growth rates as a result of the interfacial adsorption of these protein molecules, which is a newly discovered impurity effect for crystal growth. As the convection caused by gravity may mitigate or modify this effect, secure observations of this effect were first made possible by continuous measurements of normal growth rates under long-term microgravity condition realized only in the spacecraft. Our findings will lead to a better understanding of a novel kinetic process for growth oscillation in relation to growth promotion due to the adsorption of protein molecules and will shed light on the role that crystal growth kinetics has in the onset of the mysterious antifreeze effect in living organisms, namely, how this protein may prevent fish freezing.

  10. Oscillations and accelerations of ice crystal growth rates in microgravity in presence of antifreeze glycoprotein impurity in supercooled water

    NASA Astrophysics Data System (ADS)

    Furukawa, Yoshinori; Nagashima, Ken; Nakatsubo, Shun-Ichi; Yoshizaki, Izumi; Tamaru, Haruka; Shimaoka, Taro; Sone, Takehiko; Yokoyama, Etsuro; Zepeda, Salvador; Terasawa, Takanori; Asakawa, Harutoshi; Murata, Ken-Ichiro; Sazaki, Gen

    2017-03-01

    The free growth of ice crystals in supercooled bulk water containing an impurity of glycoprotein, a bio-macromolecule that functions as ‘antifreeze’ in living organisms in a subzero environment, was observed under microgravity conditions on the International Space Station. We observed the acceleration and oscillation of the normal growth rates as a result of the interfacial adsorption of these protein molecules, which is a newly discovered impurity effect for crystal growth. As the convection caused by gravity may mitigate or modify this effect, secure observations of this effect were first made possible by continuous measurements of normal growth rates under long-term microgravity condition realized only in the spacecraft. Our findings will lead to a better understanding of a novel kinetic process for growth oscillation in relation to growth promotion due to the adsorption of protein molecules and will shed light on the role that crystal growth kinetics has in the onset of the mysterious antifreeze effect in living organisms, namely, how this protein may prevent fish freezing.

  11. Oscillations and accelerations of ice crystal growth rates in microgravity in presence of antifreeze glycoprotein impurity in supercooled water

    PubMed Central

    Furukawa, Yoshinori; Nagashima, Ken; Nakatsubo, Shun-ichi; Yoshizaki, Izumi; Tamaru, Haruka; Shimaoka, Taro; Sone, Takehiko; Yokoyama, Etsuro; Zepeda, Salvador; Terasawa, Takanori; Asakawa, Harutoshi; Murata, Ken-ichiro; Sazaki, Gen

    2017-01-01

    The free growth of ice crystals in supercooled bulk water containing an impurity of glycoprotein, a bio-macromolecule that functions as ‘antifreeze’ in living organisms in a subzero environment, was observed under microgravity conditions on the International Space Station. We observed the acceleration and oscillation of the normal growth rates as a result of the interfacial adsorption of these protein molecules, which is a newly discovered impurity effect for crystal growth. As the convection caused by gravity may mitigate or modify this effect, secure observations of this effect were first made possible by continuous measurements of normal growth rates under long-term microgravity condition realized only in the spacecraft. Our findings will lead to a better understanding of a novel kinetic process for growth oscillation in relation to growth promotion due to the adsorption of protein molecules and will shed light on the role that crystal growth kinetics has in the onset of the mysterious antifreeze effect in living organisms, namely, how this protein may prevent fish freezing. PMID:28262787

  12. Stability and chaotic dynamics of a rate gyro with feedback control under uncertain vehicle spin and acceleration

    NASA Astrophysics Data System (ADS)

    Chen, Heng-Hui

    2004-06-01

    An analysis of stability and chaotic dynamics is presented by a single-axis rate gyro subjected to linear feedback control loops. This rate gyro is supposed to be mounted on a space vehicle which undergoes an uncertain angular velocity ωZ( t) around its spin axis. And simultaneously acceleration ω˙X(t) occurs with respect to the output axis. The necessary and sufficient conditions of stability for the autonomous case, whose vehicle undergoes a steady rotation, were provided by Routh-Hurwitz theory. Also, the degeneracy conditions of the non-hyperbolic point were derived and the dynamics of the resulting system on the center manifold near the double-zero degenerate point by using center manifold and normal form methods were examined. The stability of the non-linear non-autonomous system was investigated by Liapunov stability and instability theorems. As the electrical time constant is much smaller than the mechanical time constant, the singularly perturbed system can be obtained by the singular perturbation theory. The Liapunov stability of this system by studying the reduced and boundary-layer systems was also analyzed. Numerical simulations were performed to verify the analytical results. The stable regions of the autonomous system were obtained in parametric diagrams. For the non-autonomous case in which ωZ( t) oscillates near boundary of stability, periodic, quasiperiodic and chaotic motions were demonstrated by using time history, phase plane and Poincaré maps.

  13. Mimosoid legume plastome evolution: IR expansion, tandem repeat expansions, and accelerated rate of evolution in clpP

    PubMed Central

    Dugas, Diana V.; Hernandez, David; Koenen, Erik J.M.; Schwarz, Erika; Straub, Shannon; Hughes, Colin E.; Jansen, Robert K.; Nageswara-Rao, Madhugiri; Staats, Martijn; Trujillo, Joshua T.; Hajrah, Nahid H.; Alharbi, Njud S.; Al-Malki, Abdulrahman L.; Sabir, Jamal S. M.; Bailey, C. Donovan

    2015-01-01

    The Leguminosae has emerged as a model for studying angiosperm plastome evolution because of its striking diversity of structural rearrangements and sequence variation. However, most of what is known about legume plastomes comes from few genera representing a subset of lineages in subfamily Papilionoideae. We investigate plastome evolution in subfamily Mimosoideae based on two newly sequenced plastomes (Inga and Leucaena) and two recently published plastomes (Acacia and Prosopis), and discuss the results in the context of other legume and rosid plastid genomes. Mimosoid plastomes have a typical angiosperm gene content and general organization as well as a generally slow rate of protein coding gene evolution, but they are the largest known among legumes. The increased length results from tandem repeat expansions and an unusual 13 kb IR-SSC boundary shift in Acacia and Inga. Mimosoid plastomes harbor additional interesting features, including loss of clpP intron1 in Inga, accelerated rates of evolution in clpP for Acacia and Inga, and dN/dS ratios consistent with neutral and positive selection for several genes. These new plastomes and results provide important resources for legume comparative genomics, plant breeding, and plastid genetic engineering, while shedding further light on the complexity of plastome evolution in legumes and angiosperms. PMID:26592928

  14. Calocube-A highly segmented calorimeter for a space based experiment

    NASA Astrophysics Data System (ADS)

    D`Alessandro, R.; Adriani, O.; Agnesi, A.; Albergo, S.; Auditore, L.; Basti, A.; Berti, E.; Bigongiari, G.; Bonechi, L.; Bonechi, S.; Bongi, M.; Bonvicini, V.; Bottai, S.; Brogi, P.; Carotenuto, G.; Castellini, G.; Cattaneo, P. W.; Cauz, D.; Chiari, M.; Daddi, N.; Detti, S.; Fasoli, M.; Finetti, N.; Gregorio, A.; Lenzi, P.; Maestro, P.; Marrocchesi, P. S.; Miritello, M.; Mori, N.; Pacini, L.; Papini, P.; Pauletta, G.; Pirzio, F.; Rappazzo, G. F.; Rappoldi, A.; Ricciarini, S.; Santi, L. G.; Spillantini, P.; Starodubtsev, O.; Suh, J. E.; Sulaj, A.; Tiberio, A.; Tricomi, A.; Trifiro, A.; Trimarchi, M.; Vannuccini, E.; Vedda, A.; Zampa, G.; Zampa, N.; Zerbo, B.

    2016-07-01

    Future research in High Energy Cosmic Ray Physics concerns fundamental questions on their origin, acceleration mechanism, and composition. Unambiguous measurements of the energy spectra and of the composition of cosmic rays at the "knee" region could provide some of the answers to the above questions. Only ground based observations, which rely on sophisticated models describing high energy interactions in the earth's atmosphere, have been possible so far due to the extremely low particle rates at these energies. A calorimeter based space experiment can provide not only flux measurements but also energy spectra and particle identification, especially when coupled to a dE/dx measuring detector, and thus overcome some of the limitations plaguing ground based experiments. For this to be possible very large acceptances are needed if enough statistic is to be collected in a reasonable time. This contrasts with the lightness and compactness requirements for space based experiments. A novel idea in calorimetry is discussed here which addresses these issues while limiting the mass and volume of the detector. In fact a small prototype is currently being built and tested with ions. In this paper the results obtained will be presented in light of the simulations performed.

  15. Sensor response rate accelerator

    DOEpatents

    Vogt, Michael C.

    2002-01-01

    An apparatus and method for sensor signal prediction and for improving sensor signal response time, is disclosed. An adaptive filter or an artificial neural network is utilized to provide predictive sensor signal output and is further used to reduce sensor response time delay.

  16. Commissioning of the ATLAS Liquid Argon Calorimeters

    SciTech Connect

    Cooke, Mark S.

    2009-12-17

    A selection of ATLAS liquid argon (LAr) calorimeter commissioning studies is presented. It includes a coherent noise study, a measurement of the quality of the ionization pulse shape prediction, and energy and time reconstruction analyses with cosmic and single beam signals.

  17. Steel specification for the Atlas calorimeter

    SciTech Connect

    Guarino, V.

    1998-02-10

    As part of a collaborative experimental High Energy Physics experiment at the LHC Facility, CERN Laboratory, Geneva Switzerland, a group of US institutions has accepted the responsibility for constructing a large portion of the calorimeter for this experiment. This device is referred to as the Tile Calorimeter. The Tile Calorimeter has three major elements, a large center section (Barrel), and two end sections (Extended Barrel). The US group will be responsible for the construction of one of these extended barrel sections. All of the components that are required to construct this device will be fabricated in the US over a period of three years commencing in 1998. Another similar element and the barrel element will be constructed in both eastern and western Europe by parallel groups. The extended barrel is a cylindrical device approximately 8.5 meters (28 ft.) OD x 4.5 meters (14 ft.) ID, made up of 64 wedges. Each of these wedges (see Attachment 1) is constructed by bolting submodules to a strongback girder. Each submodule is constructed of a series of sheets that are welded and glued together. This document summarizes the characteristics and specifications of these steel sheets. The Tile Calorimeter is the return path for the magnet flux of the ATLAS internal superconducting 2T solenoid, therefore its steel magnetic properties are important.

  18. SLD liquid argon calorimeter prototype test results

    SciTech Connect

    Dubois, R.; Eigen, G.; Au, Y.; Sleeman, J.; Breidenbach, M.; Brau, J.; Ludgate, G.A.; Oram, C.J.; Cook, V.; Johnson, J.

    1985-10-01

    The results of the SLD test beam program for the selection of a calorimeter radiator composition within a liquid argon system are described, with emphasis on the study of the use of uranium to obtain equalization of pion and electron responses.

  19. Performance of the GEM electromagnetic calorimeter

    SciTech Connect

    Hong Ma

    1993-06-25

    The GEM EM calorimeter is optimized for the best energy, position, angular resolution and jet rejection. The detailed simulation results are presented. In the barrel with LKr, an energy resolution of about 6%/{radical}{direct_sum}0.4%, pointing resolution of 40mrad/{radical}E + 0.5mrad, and jet rejection of a factor of 5 are expected.

  20. Performance prospects for the CMS electromagnetic calorimeter barrel avalanche photodiodes for LHC phase I and phase II: Radiation hardness and longevity

    NASA Astrophysics Data System (ADS)

    Addesa, F.; Cavallari, F.

    2015-07-01

    The electromagnetic calorimeter of the Compact Muon Solenoid (CMS) experiment at the LHC is a hermetic, fine-grained, homogeneous calorimeter, comprising 75,848 lead tungstate scintillating crystals. Avalanche photodiodes produced by Hamamatsu are used as sensors for the electromagnetic barrel calorimeter. These devices were tested for radiation hardness assuming an integrated luminosity of 500 fb-1, which corresponds to a neutron fluence of 2- 4 ×1013 n /cm2, depending on the detector location. Beginning in 2022, a new phase of the LHC is foreseen to exploit the full potential of the accelerator, which will deliver 3000 fb-1 of integrated luminosity. Irradiation studies up to a fluence of 1.5 ×1014 n /cm2 have been performed to qualify the avalanche photodiodes for radiation hardness. We present measurements of gain, quantum efficiency and noise, and discuss the implications for the CMS electromagnetic barrel calorimeter performance.

  1. Beryllium fluoride exchange rate accelerated by Mg²⁺ as discovered by ¹⁹F NMR.

    PubMed

    Liu, Yixiang; Mao, Xi-an; Liu, Maili; Jiang, Ling

    2015-01-08

    Beryllium fluoride is widely used as a phosphoryl analogue in macromolecular studies, which are not only fluoride-sensitive but also magnesium-dependent. The beryllium fluorides are a mixture of different species including BeF3(-) and BeF4(2-) exchanging under thermodynamic equilibrium in neutral aqueous solutions. In the cases of mimicking phosphate group transfer, both beryllium fluoride and the magnesium ion are generally needed. However, the impact of magnesium on the bioactivity of beryllium fluoride is not clear. We have found by (19)F NMR spectroscopy that Mg(2+) can severely affect the chemical exchange kinetics between BeF3(-) and BeF4(2-). When the F(-) concentration is relatively low, the presence of 10.0 mM Mg(2+) can accelerate the exchange rate 3-4 fold. However, when the F(-) concentration is relatively high, the Mg(2+) effect on the chemical exchange vanishes. On the basis of these findings, we proposed a possible mechanism that BeF4(2-) and Mg(2+) form an ion pair that affects the distribution of beryllium fluoride species and thus the activity in the solution.

  2. Compressor calorimeter performance of refrigerant blends: Comparative methods and results for a refrigerator/freezer application

    SciTech Connect

    Rice, C K; Sand, J R

    1993-01-01

    A protocol was developed to define calorimeter operating pressures for nonazeotropic refrigerant mixtures (NARMs) which corresponded with the saturated evaporator and condenser temperatures commonly used for pure refrigerants. Compressor calorimeter results were obtained using this equivalent-mean-temperature (EMT) approach and a generally applied Association of Home Appliance Manufacturers (AHAM) procedure at conditions characteristic of a domestic refrigerator-freezer application. Tests with R-12 and two NARMs indicate that compressor volumetric and isentropic efficiencies are nearly the same for refrigerants with similar capacities and pressure ratios. The liquid-line temperature conditions specified in the AHAM calorimeter rating procedure for refrigerator-freezer compressors were found to preferentially derate NARM performance relative to R-12. Conversion of calorimeter data taken with a fixed liquid-line temperature to a uniform minimal level of condenser subcooling is recommended as a fairer procedure when NARMs are involved. Compressor energy-efficiency-ratio (EER) and capacity data measured as a result of the EMT approach were compared to system performance calculated using an equivalent-heat-exchanger-loading (EHXL) protocol based on a Lorenz-Meutzner (L-M) refrigerator-freezer modeling program. The EHXL protocol was used to transform the calorimeter results into a more relevant representation of potential L-M cycle performance. The EMT method used to set up the calorimeter tests and the AHAM liquid-line conditions combined to significantly understate the cycle potential of NARMs relative to that predicted at the more appropriate EHXL conditions. Compressor conditions representative of larger heat exchanger sizes were also found to give a smaller L-M cycle advantage relative to R-12.

  3. Compressor calorimeter performance of refrigerant blends: Comparative methods and results for a refrigerator/freezer application

    NASA Astrophysics Data System (ADS)

    Rice, C. K.; Sand, J. R.

    1993-01-01

    A protocol was developed to define calorimeter operating pressures for nonazeotropic refrigerant mixtures (NARM's) which corresponded with the saturated evaporator and condenser temperatures commonly used for pure refrigerants. Compressor calorimeter results were obtained using this equivalent-mean-temperature (EMT) approach and a generally applied Association of Home Appliance Manufacturers (AHAM) procedure at conditions characteristic of a domestic refrigerator-freezer application. Tests with R-12 and two NARM's indicate that compressor volumetric and isentropic efficiencies are nearly the same for refrigerants with similar capacities and pressure ratios. The liquid-line temperature conditions specified in the AHAM calorimeter rating procedure for refrigerator-freezer compressors were found to preferentially derate NARM performance relative to R-12. Conversion of calorimeter data taken with a fixed liquid-line temperature to a uniform minimal level of condenser subcooling is recommended as a fairer procedure when NARM's are involved. Compressor energy-efficiency-ratio (EER) and capacity data measured as a result of the EMT approach were compared to system performance calculated using an equivalent heat exchanger loading (EHXL) protocol based on a Lorenz-Meutzner (L-M) refrigerator-freezer modeling program. The EHXL protocol was used to transform the calorimeter results into a more relevant representation of potential L-M cycle performance. The EMT method used to set up the calorimeter tests and the AHAM liquid-line conditions combined to significantly understate the cycle potential of NARM's relative to that predicted at the more appropriate EHXL conditions. Compressor conditions representative of larger heat exchanger sizes were also found to give a smaller L-M cycle advantage relative to R-12.

  4. X-Ray Calorimeter Arrays for Astrophysics

    NASA Technical Reports Server (NTRS)

    Kilbourne, Caroline A.

    2009-01-01

    High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.

  5. Experience-dependent enhancement of pitch-specific responses in the auditory cortex is limited to acceleration rates in normal voice range

    PubMed Central

    Krishnan, Ananthanarayan; Gandour, Jackson T.; Suresh, Chandan H.

    2015-01-01

    The aim of this study is to determine how pitch acceleration rates within and outside the normal pitch range may influence latency and amplitude of cortical pitch-specific responses (CPR) as a function of language experience (Chinese, English). Responses were elicited from a set of four pitch stimuli chosen to represent a range of acceleration rates (two each inside and outside the normal voice range) imposed on the high rising Mandarin Tone 2. Pitch-relevant neural activity, as reflected in the latency and amplitude of scalp-recorded CPR components, varied depending on language-experience and pitch acceleration of dynamic, time-varying pitch contours. Peak latencies of CPR components were shorter in the Chinese than the English group across stimuli. Chinese participants showed greater amplitude than English for CPR components at both frontocentral and temporal electrode sites in response to pitch contours with acceleration rates inside the normal voice pitch range as compared to pitch contours with acceleration rates that exceed the normal range. As indexed by CPR amplitude at the temporal sites, a rightward asymmetry was observed for the Chinese group only. Only over the right temporal site was amplitude greater in the Chinese group relative to the English. These findings may suggest that the neural mechanism(s) underlying processing of pitch in the right auditory cortex reflect experience-dependent modulation of sensitivity to acceleration in just those rising pitch contours that fall within the bounds of one’s native language. More broadly, enhancement of native pitch stimuli and stronger rightward asymmetry of CPR components in the Chinese group is consistent with the notion that long-term experience shapes adaptive, distributed hierarchical pitch processing in the auditory cortex, and reflects an interaction with higher-order, extrasensory processes beyond the sensory memory trace. PMID:26166727

  6. Accelerated partial breast irradiation in the elderly: 5-year results of high-dose rate multi-catheter brachytherapy

    PubMed Central

    2014-01-01

    Objective To evaluate clinical outcome after accelerated partial breast irradiation (APBI) in the elderly after high-dose-rate interstitial multi-catheter brachytherapy (HIBT). Methods and materials Between 2005 and 2013, 70 patients underwent APBI using HIBT. Catheter implant was performed intra or post-operatively (referred patients) after lumpectomy and axillary sentinel lymph node dissection. Once the pathological results confirmed the indication of APBI, planification CT-scan was performed to deliver 34 Gy/10f/5d or 32 Gy/8f/4d. Dose-volume adaptation was manually achieved (graphical optimization). Dosimetric results and clinical outcome were retrospectively analyzed. Physician cosmetic evaluation was reported. Results With a median follow-up of 60.9 months [4.6 – 90.1], median age was 80.7 years [62 – 93.1]. Regarding APBI ASTRO criteria, 61.4%, 18.6% and 20% were classified as suitable, cautionary and non-suitable respectively. Axillary sentinel lymph node dissection was performed in 94.3%; 8 pts (11.5%) presented an axillary involvement. A median dose of 34 Gy [32 – 35] in 8 to 10 fractions was delivered. Median CTV was 75.2 cc [16.9 – 210], median D90 EQD2 was 43.3 Gy [35 – 72.6] and median DHI was 0.54 [0.19 – 0.74]. One patient experienced ipsilateral recurrence (5-year local free recurrence rate: 97.6%. Five-year specific and overall survival rates were 97.9% and 93.2% respectively. Thirty-four patients (48%) presented 47 late complications classified grade 1 (80.8%) and grade 2 (19.2%) with no grade ≥ 3. Cosmetic results were considered excellent/good for 67 pts (95.7%). Conclusion APBI using HIBT and respecting strict rules of implantation and planification, represents a smart alternative between no post-operative irradiation and whole breast irradiation delivered over 6 consecutive weeks. PMID:24886680

  7. Development and Initial Validation of the Student Rating of Environmental Stressors Scale: Stressors Faced by Students in Accelerated High School Curricula

    ERIC Educational Resources Information Center

    Suldo, Shannon M.; Dedrick, Robert F.; Shaunessy-Dedrick, Elizabeth; Roth, Rachel A.; Ferron, John

    2015-01-01

    High school students in accelerated curricula face stressors beyond typical adolescent developmental challenges. The Student Rating of Environmental Stressors Scale (StRESS) is a self-report measure of environmental stressors appropriate for students in Advanced Placement (AP) and International Baccalaureate (IB) courses. We developed the StRESS…

  8. Hydrogen bonding mediated enantioselective organocatalysis in brine: significant rate acceleration and enhanced stereoselectivity in enantioselective Michael addition reactions of 1,3-dicarbonyls to β-nitroolefins.

    PubMed

    Bae, Han Yong; Some, Surajit; Oh, Joong Suk; Lee, Yong Seop; Song, Choong Eui

    2011-09-14

    Brine provides remarkable rate acceleration and a higher level of stereoselectivity over organic solvents, due to the hydrophobic hydration effect, in the enantioselective Michael addition reactions of 1,3-dicarbonyls to β-nitroolefins using chiral H-donors as organocatalysts.

  9. ATLAS level-1 calorimeter trigger: Monitoring and data reprocessing

    NASA Astrophysics Data System (ADS)

    Dimond, David; Hong, Tae; Carlson, Benjamin; Atlas Collaboration

    2017-01-01

    We present the monitoring and data reprocessing for the calorimeter-based hardware level-1 trigger system (L1Calo) for the ATLAS experiment. This trigger system was upgraded after the Run-1 data taking period (2009-2012) to prepare for Run-2 (2015-current), which allowed better control the event rates for algorithms based on jets and/or missing energy. Monitoring tools for the upgraded system is described. We also present a new offline tool to reprocess previous data samples with altered L1Calo settings, such as calibration constants and noise cuts. The samples are used to study the dependence of the event rates and signal efficiencies on the settings. The studies can help plan the appropriate L1Calo settings for upcoming data taking periods as well as for future runs.

  10. Effect of dead material in a calorimeter

    SciTech Connect

    Green, D.

    1995-10-01

    The existence of dead material in any practical calorimeter system is simply a fact of life. The task for the designer, then, is to understand the impact on the Physics in question, and strive to minimize it. The aim of this note is to use the ``Hanging File`` test data, which has fined grained individual readout of about 100 depth segments, to explore impact of dead material on the mean and r.m.s. of the hadronic distribution. The amount and location of the dead material is varied. It important to remember that the Hanging File data was calibrated, EM to HCAL compartment, so as to minimize the electron to pion energy dependence. In practical terms e/pie was made = 1.0 at an incident energy of about 100 GeV. Note that the PB(EM) + FE(HCAL) calorimeter was not a compensating device.

  11. Level-2 Calorimeter Trigger Upgrade at CDF

    SciTech Connect

    Flanagan, G.U.; /Purdue U.

    2007-04-01

    The CDF Run II Level-2 calorimeter trigger is implemented in hardware and is based on an algorithm used in Run I. This system insured good performance at low luminosity obtained during the Tevatron Run II. However, as the Tevatron instantaneous luminosity increases, the limitations of the current system due to the algorithm start to become clear. In this paper, we will present an upgrade of the Level-2 calorimeter trigger system at CDF. The upgrade is based on the Pulsar board, a general purpose VME board developed at CDF and used for upgrading both the Level-2 tracking and the Level-2 global decision crate. This paper will describe the design, hardware and software implementation, as well as the advantages of this approach over the existing system.

  12. Improving calorimeter resolution using temperature compensation calculations

    NASA Astrophysics Data System (ADS)

    Smiga, Joseph; Purschke, Martin

    2017-01-01

    The sPHENIX experiment is an upgrade of the existing PHENIX apparatus at the Relativistic Heavy-Ion Collider (RHIC). The new detector improves upon measurements of various physical processes, such as jets of particles created during heavy-ion collisions. Prototypes of various calorimeter components were tested at the Fermilab Test Beam Facility (FTBF). This analysis tries to compensate the effects of temperature drifts in the silicon photomultipliers (SiPMs). Temperature data were used to calculate an appropriate compensation factor. This analysis will improve the achievable resolution and will also determine how accurately the temperature must be controlled in the final experiment. This will improve the performance of the calorimeters in the sPHENIX experiment. This project was supported in part by the U.S. Department of Energy, Office of Science, Office of Workforce Development for Teachers and Scientists (WDTS) under the Science Undergraduate Laboratory Internships Program (SULI).

  13. Sources of compensation in hadronic calorimeters

    SciTech Connect

    Goodman, M.S.; Gabriel, T.A.; Di Ciaccio, A.; Wilson, R.

    1988-12-01

    Monte Carlo simulations are presented using the CALOR code system to study the design of a large hybrid hadron calorimeter system employing a warm liquid active medium (tetramethylsilane, Si(CH/sub 3/)/sub 4/) and uranium plates in addition to a conventional Fe/plastic system. In the system described here, the uranium provides partial compensation by suppressing the electromagnetic cascade produced by incident electrons due to sampling inefficiencies. The results of the simulations also indicate that significant compensation is achieved (given small enough saturation) due to low energy recoil protons produced in collisions with low energy (1--20 MeV) cascade and fission neutrons in the active medium. Both compensation mechanisms are important to help balance the response of a calorimeter to incident electrons and hadrons, that is, to achieve a ratio of pulse heights (e/h approx. 1) which will lead to the best energy resolution. 17 refs., 4 figs., 2 tabs.

  14. Upgrade of the ATLAS Tile Calorimeter Electronics

    NASA Astrophysics Data System (ADS)

    Carrió, F.; Tile Calorimeter System, ATLAS

    2015-02-01

    The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the central region of the ATLAS experiment at LHC. The TileCal readout consists of about 10000 channels. The bulk of its upgrade will occur for the High Luminosity LHC phase (Phase-II) where the peak luminosity will increase 5 times compared to the design luminosity (1034 cm-2s-1) but with maintained energy (i.e. 7+7 TeV). An additional increase of the average luminosity with a factor of 2 can be achieved by luminosity levelling. This upgrade is expected to happen around 2024. The TileCal upgrade aims at replacing the majority of the on- and off- detector electronics to the extent that all calorimeter signals will be digitized and sent to the off-detector electronics in the counting room. To achieve the required reliability, redundancy has been introduced at different levels. Three different options are presently being investigated for the front-end electronic upgrade. Extensive test beam studies will determine which option will be selected. 10 Gbps optical links are used to read out all digitized data to the counting room while 5 Gbps down-links are used for synchronization, configuration and detector control. For the off-detector electronics a pre-processor (sROD) is being developed, which takes care of the initial trigger processing while temporarily storing the main data flow in pipeline and derandomizer memories. One demonstrator prototype module with the new calorimeter module electronics, but still compatible with the present system, is planned to be inserted in ATLAS this year.

  15. A no-load RF calorimeter

    NASA Technical Reports Server (NTRS)

    Chernoff, R. C.

    1975-01-01

    The described device can be used to measure the output of any dc powered RF source. No dummy load is required for the measurements. The device is, therefore, called the 'no-load calorimeter' (NLC). The NLC measures the power actually fed to the antenna or another useful load. It is believed that the NLC can compete successfully with directional coupler type systems in measuring the output of high-power RF sources.

  16. Limitations of current dosimetry for intracavitary accelerated partial breast irradiation with high dose rate iridium-192 and electronic brachytherapy sources

    NASA Astrophysics Data System (ADS)

    Raffi, Julie A.

    Intracavitary accelerated partial breast irradiation (APBI) is a method of treating early stage breast cancer using a high dose rate (HDR) brachytherapy source positioned within the lumpectomy cavity. An expandable applicator stretches the surrounding tissue into a roughly spherical or elliptical shape and the dose is prescribed to 1 cm beyond the edge of the cavity. Currently, dosimetry for these treatments is most often performed using the American Association of Physicists in Medicine Task Group No. 43 (TG-43) formalism. The TG-43 dose-rate equation determines the dose delivered to a homogeneous water medium by scaling the measured source strength with standardized parameters that describe the radial and angular features of the dose distribution. Since TG-43 parameters for each source model are measured or calculated in a homogeneous water medium, the dosimetric effects of the patient's dimensions and composition are not accounted for. Therefore, the accuracy of TG-43 calculations for intracavitary APBI is limited by the presence of inhomogeneities in and around the target volume. Specifically, the breast is smaller than the phantoms used to determine TG-43 parameters and is surrounded by air, ribs, and lung tissue. Also, the composition of the breast tissue itself can affect the dose distribution. This dissertation is focused on investigating the limitations of TG-43 dosimetry for intracavitary APBI for two HDR brachytherapy sources: the VariSource TM VS2000 192Ir source and the AxxentRTM miniature x-ray source. The dose for various conditions was determined using thermoluminescent dosimeters (TLDs) and Monte Carlo (MC) calculations. Accurate measurements and calculations were achieved through the implementation of new measurement and simulation techniques and a novel breast phantom was developed to enable anthropomorphic phantom measurements. Measured and calculated doses for phantom and patient geometries were compared with TG-43 calculated doses to

  17. Precision timing calorimeter for high energy physics

    NASA Astrophysics Data System (ADS)

    Anderson, Dustin; Apresyan, Artur; Bornheim, Adolf; Duarte, Javier; Peña, Cristián; Spiropulu, Maria; Trevor, Jason; Xie, Si; Ronzhin, Anatoly

    2016-07-01

    Scintillator based calorimeter technology is studied with the aim to achieve particle detection with a time resolution on the order of a few 10 ps for photons and electrons at energies of a few GeV and above. We present results from a prototype of a 1.4×1.4×11.4 cm3 sampling calorimeter cell consisting of tungsten absorber plates and Cerium-doped Lutetium Yttrium Orthosilicate (LYSO) crystal scintillator plates. The LYSO plates are read out with wave lengths shifting fibers which are optically coupled to fast photo detectors on both ends of the fibers. The measurements with electrons were performed at the Fermilab Test Beam Facility (FTBF) and the CERN SPS H2 test beam. In addition to the baseline setup plastic scintillation counter and a MCP-PMT were used as trigger and as a reference for a time of flight measurement (TOF). We also present measurements with a fast laser to further characterize the response of the prototype and the photo sensors. All data were recorded using a DRS4 fast sampling digitizer. These measurements are part of an R&D program whose aim is to demonstrate the feasibility of building a large scale electromagnetic calorimeter with a time resolution on the order of 10 ps, to be used in high energy physics experiments.

  18. Preliminary conceptual design about the CEPC calorimeters

    NASA Astrophysics Data System (ADS)

    Yang, Haijun

    2016-11-01

    The Circular Electron Positron Collider (CEPC) as a Higgs factory was proposed in September 2013. The preliminary conceptual design report was completed in 2015.1 The CEPC detector design was using International Linear Collider Detector — ILD2 as an initial baseline. The CEPC calorimeters, including the high granularity electromagnetic calorimeter (ECAL) and the hadron calorimeter (HCAL), are designed for precise energy measurements of electrons, photons, taus and hadronic jets. The basic resolution requirements for the ECAL and HCAL are about 16%E (GeV) and 50%E (GeV), respectively. To fully exploit the physics potential of the Higgs, W, Z and related Standard Model processes, the jet energy resolution is required to reach 3%-4%, or 30%/E (GeV) at energies below about 100 GeV. To achieve the required performance, a Particle Flow Algorithm (PFA) — oriented calorimetry system is being considered as the baseline design. The CEPC ECAL detector options include silicon-tungsten or scintillator-tungsten structures with analog readout, while the HCAL detector options have scintillator or gaseous detector as the active sensor and iron as the absorber. Some latest R&D studies about ECAL and HCAL within the CEPC working group is also presented.

  19. Fiber and crystals dual readout calorimeters

    NASA Astrophysics Data System (ADS)

    Cascella, Michele; Franchino, Silvia; Lee, Sehwook

    2016-11-01

    The RD52 (DREAM) collaboration is performing R&D on dual readout calorimetry techniques with the aim of improving hadronic energy resolution for future high energy physics experiments. The simultaneous detection of Cherenkov and scintillation light enables us to measure the electromagnetic fraction of hadron shower event-by-event. As a result, we could eliminate the main fluctuation which prevented from achieving precision energy measurement for hadrons. We have tested the performance of the lead and copper fiber prototypes calorimeters with various energies of electromagnetic particles and hadrons. During the beam test, we investigated the energy resolutions for electrons and pions as well as the identification of those particles in a longitudinally unsegmented calorimeter. Measurements were also performed on pure and doped PbWO4 crystals, as well as BGO and BSO, with the aim of realizing a crystal based dual readout detector. We will describe our results, focusing on the more promising properties of homogeneous media for the technique. Guidelines for additional developments on crystals will be also given. Finally we discuss the construction techniques that we have used to assemble our prototypes and give an overview of the ones that could be industrialized for the construction of a full hermetic calorimeter.

  20. Calibrating the Muon Piston Calorimeter (MPC)

    NASA Astrophysics Data System (ADS)

    Skolnik, Marianne

    2012-10-01

    The Muon Piston Calorimeter (MPC) is a subsystem of the PHENIX detector. The MPC, an electromagnetic calorimeter, is effective at measuring the energy of photons and electrons produced from collisions at the Relativistic Heavy Ion Collider (RHIC). The MPC outputs a voltage signal that we then convert into an energy reading. One common way to calibrate electromagnetic calorimeters is to use photons from π^0 decays. Since many of the photons that enter the detector are the result of natural pion decay, we can pair up the photons and create π^0 candidates. We then plot their masses tower by tower and with the correct cuts a mass peak will appear close to the position predicted by the simulation PISA of the PHENIX detector. Then, we relate the mass peaks from the measured data to mass peaks from simulated data to adjust the gains. Once the MPC is calibrated we can use it to study Au+Au collisions. Previously, the detector has been used to study spin physics using data collected from p+p collisions, and cold nuclear matter effects using d+Au collisions. These new calibrations will allow us to measure new global variables such as transverse energy in both the forward and backward kinematic regions, 3.1< |η| < 3.9.

  1. Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter

    SciTech Connect

    Harty, P. D. Ramanathan, G.; Butler, D. J.; Johnston, P. N.; Lye, J. E.; Hall, C. J.; Stevenson, A. W.

    2014-05-15

    Purpose: The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free-air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and provide confidence in the first implementation of a graphite calorimeter on a synchrotron medical beam line. Methods: The graphite calorimeter has a core which rises in temperature when irradiated by the beam. A collimated x-ray beam from the synchrotron with well-defined edges was used to partially irradiate the core. Two filtration sets were used, one corresponding to an average beam energy of about 80 keV, with dose rate about 50 Gy/s, and the second filtration set corresponding to average beam energy of 90 keV, with dose rate about 20 Gy/s. The temperature rise from this beam was measured by a calibrated thermistor embedded in the core which was then converted to absorbed dose to graphite by multiplying the rise in temperature by the specific heat capacity for graphite and the ratio of cross-sectional areas of the core and beam. Conversion of the measured absorbed dose to graphite to absorbed dose to water was achieved using Monte Carlo calculations with the EGSnrc code. The air kerma measurements from the free-air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. Results: Absolute measurements of the IMBL dose rate were made using the graphite calorimeter and compared to measurements with the free-air chamber. The measurements were at three different depths in graphite and two different filtrations. The calorimetry measurements at depths in graphite show agreement within 1% with free-air chamber measurements, when converted to absorbed dose to water. The calorimetry at the surface and free-air chamber results show agreement of order 3% when converted to absorbed dose to water. The combined standard uncertainty is 3

  2. A hadron calorimeter with scintillators parallel to the beam

    NASA Astrophysics Data System (ADS)

    Abramov, V.; Goncharov, P.; Gorin, A.; Gurzhiev, A.; Dyshkant, A.; Evdokimov, V.; Kolosov, V.; Korablev, A.; Korneev, Yu.; Kostritskii, A.; Krinitsyn, A.; Kryshkin, V.; Podstavkov, V.; Polyakov, V.; Shtannikov, A.; Tereschenko, S.; Turchanovich, L.; Zaichenko, A.

    1997-02-01

    A hadron calorimeter in which scintillators are arranged nearly parallel to the incident particle direction and light is collected by optical fibres with WLS, has been built. The iron absorber plates are of the tapered shape to fit a barrel structure of the collider geometry. The performance of the calorimeter studied with hadron beam is presented as a function of tilt angle without and with electromagnetic calorimeter in front of the hadron one.

  3. Heat flow calorimeter. [measures output of Ni-Cd batteries

    NASA Technical Reports Server (NTRS)

    Fletcher, J. C.; Johnston, W. V. (Inventor)

    1974-01-01

    Heat flow calorimeter devices are used to measure heat liberated from or absorbed by an object. This device is capable of measuring the thermal output of sealed nickel-cadmium batteries or cells during charge-discharge cycles. An elongated metal heat conducting rod is coupled between the calorimeter vessel and a heat sink, thus providing the only heat exchange path from the calorimeter vessel itself.

  4. Test beam performance of the CDF plug upgrade hadron calorimeter

    SciTech Connect

    de Barbaro, P.; CDF Plug Upgrade Group

    1998-01-13

    We report on the performance of the CDF End Plug Hadron Calorimeter in a test beam. The sampling calorimeter is constructed using 2 inch iron absorber plates and scintillator planes with wavelength shifting fibers for readout. The linearity and energy resolution of the calorimeter response to pions, and the transverse uniformity of the response to muons and pions are presented. The parameter e/h, representing the ratio of the electromagnetic to hadronic response, is extracted from the data.

  5. Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote afterloader.

    PubMed

    Melhus, C S; Rivard, M J; Kurkomelis, J; Liddle, C B; Massé, F X

    2005-01-01

    In support of the effort to begin high-dose rate 252Cf brachytherapy treatments at Tufts-New England Medical Center, the shielding capabilities of a clinical accelerator vault against the neutron and photon emissions from a 1.124 mg 252Cf source were examined. Outside the clinical accelerator vault, the fast neutron dose equivalent rate was below the lower limit of detection of a CR-39 etched track detector and below 0.14 +/- 0.02 muSv h(-1) with a proportional counter, which is consistent, within the uncertainties, with natural background. The photon dose equivalent rate was also measured to be below background levels (0.1 muSv h(-1)) using an ionisation chamber and an optically stimulated luminescence dosemeter. A Monte Carlo simulation of neutron transport through the accelerator vault was performed to validate measured values and determine the thermal-energy to low-energy neutron component. Monte Carlo results showed that the dose equivalent rate from fast neutrons was reduced by a factor of 100,000 after attenuation through the vault wall, and the thermal-energy neutron dose equivalent rate would be an additional factor of 1000 below that of the fast neutrons. Based on these findings, the shielding installed in this facility is sufficient for the use of at least 5.0 mg of 252Cf.

  6. Estimation of radiation effects in the front-end electronics of an ILC electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Bartsch, V.; Postranecky, M.; Targett-Adams, C.; Warren, M.; Wing, M.

    2008-08-01

    The front-end electronics of the electromagnetic calorimeter of an International Linear Collider detector are situated in a radiation environment. This requires the effect of the radiation on the performance of the electronics, specifically FPGAs, to be examined. In this paper we study the flux, particle spectra and deposited doses at the front-end electronics of the electromagnetic calorimeter of a detector at the ILC. We also study the occupancy of the electromagnetic calorimeter. These estimates are compared with measurements, e.g. of the radiation damage of FPGAs, done elsewhere. The outcome of the study shows that the radiation doses and the annual flux is low enough to allow today's FPGAs to operate. The Single Event Upset rate, however, lies between 14 min and 12 h depending on the FPGA used and therefore needs to be considered in the design of the data acquisition system of the electromagnetic calorimeter. The occupancy is about 0.002 per bunch train not taking into account the effect of noise which depends on the choice of the detector.

  7. Design studies of the PWO Forward End-cap calorimeter for P¯ANDA

    NASA Astrophysics Data System (ADS)

    Moeini, H.; Al-Turany, M.; Babai, M.; Biegun, A.; Bondarenko, O.; Götzen, K.; Kavatsyuk, M.; Lindemulder, M. F.; Löhner, H.; Melnychuk, D.; Messchendorp, J. G.; Smit, H. A. J.; Spataro, S.; Veenstra, R.

    2013-11-01

    The P¯ANDA detection system at FAIR, Germany, is designed to study antiproton-proton annihilations, in order to investigate, among others, the realm of charm-meson states and glueballs, which has still much to reveal. The yet unknown properties of this field are to be unraveled through studying QCD phenomena in the non-perturbative regime. The multipurpose P¯ANDA detector will be capable of tracking, calorimetry, and particle identification, and is planned to run at high luminosities providing average reaction rates up to 2 · 107 interactions/s. The envisaged physics program requires measurements of photons and charged particles with excellent energy, position, and time resolutions. The electromagnetic calorimeter (EMC) will serve as one of the basic components of the detector setup and comprises cooled lead-tungstate (PbWO4) crystals. This paper presents the mechanical design of the Forward End-cap calorimeter and analyzes the response of the Forward End-cap calorimeter in conjunction with the full EMC and the complete P¯ANDA detector. The simulation studies are focused on the performance of the planned EMC with respect to the energy and spatial resolution of the reconstructed photons. Results of the Monte Carlo simulations, excluding very low-energy photons, have been validated by data obtained from a prototype calorimeter and shown to fulfil the requirements imposed by the P¯ANDA physics program.

  8. A calorimeter for neutron flux measurement. Final report

    SciTech Connect

    Chupp, T.E.

    1993-04-01

    A calorimeter for absolute neutron flux measurement has been built and tested. The calorimeter measures the heat produced in a 10{degrees}K thick LiPb target when neutrons are captured via the {sup 6}Li(n,{sup 3}H){sup 4}He reaction. The sensitivity achieved was 1.3x10{sup 6} n/s for a 1 hour measurement. Separate flux measurements with the calorimeter and a {sup 238}U fission chamber are in agreement and show that systematic errors are less than 3%. An improved calorimeter has been built which is sensitive to 10{sup 5} n/s for a 1 hour measurement.

  9. sPHENIX Calorimeter Design and Jet Performance

    NASA Astrophysics Data System (ADS)

    Haggerty, John S.

    2016-12-01

    The PHENIX collaboration is planning a detector upgrade, sPHENIX, which consists of large acceptance calorimetry and tracking detectors built around the superconducting solenoid recently shipped to Brookhaven from the decommissioned BaBar experiment at SLAC. The sPHENIX calorimeter system includes three radial layers of sampling calorimeters, a tungsten-scintillating fiber electromagnetic calorimeter, and two longitudinally segmented sampling hadron calorimeters that are made of scintillator tiles and steel plates. Together, they provide hermetic coverage in | η | < 1 for calorimetry based jet measurements as well as minimal bias jet trigger capability, which coupled with high resolution tracking, enable an extremely rich jet physics program at RHIC.

  10. New photomultiplier active base for Hall C Jefferson Lab lead tungstate calorimeter

    SciTech Connect

    Popov, Vladimir E.; Mkrtchyan, Hamlet G.

    2012-11-01

    A new photomultiplier tube active base was designed and tested. The base combines active voltage division circuit and fast amplifier, powered by the current flowing through voltage divider. This base is developed to upgrade older photomultiplier bases of Jefferson Lab lead-tungsten calorimeter (about ˜1200 crystals of PbWO{sub 4} from the PrimEx experimental setup). This is needed for the extension of detectors' rate capability to meet requirements of new Hall C proposal PR12-11-102 of measurements of the L/T separated cross sections and their ratio R = πL/πT in neutral-pion p(e,e'π0)p deep exclusive and p(p(e,e'π{sup 0})p)X semi-inclusive scattering regions. New active base is direct replacement of older passive base circuit without adding of additional power or signal lines. However, it extends detectors rate capability with factor over 20. Moreover, transistorized voltage divider improves detector's amplitude resolution due to reduction of photomultiplier gain dependence from tube anode current. The PMT active base is the invention disclosed in V. Popov's U.S. Patent No. 6,791,269, which successfully works over ten years in several Jefferson Lab Cherenkov detectors. The following design is a new revised and improved electronic circuit with better gain stability and linearity in challenge to meet requirements of new Hall C experimental setup. New active base performance was tested using fast LED light source and Pr:LuAG scintillator and gamma sources. Electronics radiation hardness was tested on JLab accelerator. Results of testing R4125 Hamamatsu photomultiplier tube in new active base are presented.

  11. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    SciTech Connect

    Chibani, Omar C-M Ma, Charlie

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  12. Latest Pleistocene and Holocene slip rates on the Lone Mountain fault: Evidence for accelerating slip in the Silver Peak-Lone Mountain extensional complex

    NASA Astrophysics Data System (ADS)

    Lifton, Zachery M.; Frankel, Kurt L.; Newman, Andrew V.

    2015-03-01

    Determining the constancy of fault slip rates over time is critical in characterizing strain distribution across plate boundaries such as the Pacific-North American plate boundary in the western U.S. We present results from the Lone Mountain fault, a normal fault within the southern Walker Lane, that suggest slip rates there may have increased approximately twofold since the late Pleistocene. We combine detailed field surficial mapping, topographic surveying, and 10Be cosmogenic nuclide exposure ages to calculate new late Pleistocene and Holocene slip rates on the Lone Mountain fault. Alluvial fans with ages of 14.6 ± 1.4 ka and 8.0 ± 0.9 ka are vertically offset 10.2 ± 0.6 m and 4.7 ± 0.6 m, respectively, yielding vertical slip rates of 0.7 ± 0.1 mm/yr and 0.6 ± 0.1 mm/yr. These slip rates are faster than the rates of 0.1 to 0.4 mm/yr from earlier in the Pleistocene, defining a pattern of accelerating slip on the Lone Mountain fault over a timescale of 104 years. The possibility of accelerating slip rates in parts of the Walker Lane partially reconciles the observed discrepancy between long- and short-term slip rates in this region and elucidates the distribution of strain across an evolving plate boundary.

  13. A new-concept gamma calorimeter at ELI-NP

    NASA Astrophysics Data System (ADS)

    Lenzi, M.; Adriani, O.; Albergo, S.; Andreotti, M.; Berto, D.; Borgheresi, R.; Cappello, G.; Cardarelli, P.; Ciaranfi, R.; Consoli, E.; Di Domenico, G.; Evangelisti, F.; Gambaccini, M.; Graziani, G.; Marziani, M.; Palumbo, L.; Passaleva, G.; Pellegriti, M. G.; Serban, A.; Starodubtsev, O.; Statera, M.; Tricomi, A.; Variola, A.; Veltri, M.

    2017-02-01

    ELI-NP is an European Research Infrastructure that will provide a monochromatic, high brilliance gamma beam with tunable energy up to 19.5 MeV. The time structure of the beam consists of 32 high intensity gamma bunches separated by a time interval of 16 ns and delivered at a repetition rate of 100 Hz. In order to match such unprecedented beam specifications, specific devices and techniques have been developed to measure and monitor the beam parameters during the commissioning and the operational phase. This paper presents an overview of the gamma beam characterization system, with particular focus on a new-concept sampling calorimeter made of silicon detectors and polyethylene absorbers.

  14. Cycle-Powered Short Radius (1.9 m) Centrifuge: Effect of Exercise Versus Passive Acceleration on Heart Rate in Humans

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Gundo, D. P.; Watenpaugh, D. E.; Mulenburg, G. M.; Mckenzie, M. A.; Looft-Wilson, R.; Hargens, A. R.

    1997-01-01

    In addition to extensive use of lower extremity physical exercise training as a countermeasure for the work capacity component of spaceflight deconditioning, some form of additional head-to-foot (+Gz) gravitational (orthostatic) stress may be required to further attenuate or prevent the signs and symptoms (nausea, vertigo, instability, fatigue) of the general reentry syndrome (GRS) that can reduce astronaut performance during landing. Orthostatic (head-to-foot) stress can be induced by standing, by lower body negative pressure, and by +Gz acceleration. One important question is whether acceleration training alone or with concurrent leg exercise would provide sufficient additive stimulation to attenuate the GRS. Use of a new human-powered centrifuge may be the answer. Thus, the purpose for this study was to compare heart rate (HR), i.e., a stress response during human-powered acceleration, in four men (35-62 yr) and two women (30-31 yr) during exercise acceleration versus passive acceleration (by an off-board operator) at 100% (maximal acceleration = A(max)), and at 25%, 50%, and 75% of A(max). Mean (+/-SE) A(max) was 43.7 +/- 1.3 rpm (+3.9 +/- 0.2Gz). Mean HR at exercise A(max) was 189 +/- 13 b/min (50-70 sec run time), and 142 +/- 22 b/min at passive A(max) (40-70 sec run time). Regression of mean HR on the various +Gz levels indicated explained variance (correlations squared) of r(exp 2) = 0.88 (exercise) and r(exp 2) = 0.96 (passive): exercise HR of 107 +/- 4 (25%) to 189 +/- 13 (100%) b/min were 43-50 b/min higher (p less than 0.05) than comparable passive HR of 64 +/- 2 to 142 +/- 22 b/min. Thus, exercise adds significant physiological stress during +Gz acceleration. Inflight use of this combined exercise and acceleration countermeasure may maintain work capacity as well as normalize acceleration and orthostatic tolerances which could attenuate or perhaps eliminate the GRS.

  15. ATLAS LAr calorimeter performance and LHC Run-2 commissioning

    NASA Astrophysics Data System (ADS)

    Spettel, Fabian

    2016-07-01

    The ATLAS detector was built to study proton-proton collisions produced by the Large Hadron Collider (LHC) at a center of mass energy of up to 14 TeV. The Liquid Argon (LAr) calorimeters are used for all electromagnetic calorimetry as well as the hadronic calorimetry in the endcap and forward regions. They have shown excellent performance during the first LHC data taking campaign, from 2010 to 2012, so-called Run 1, at a peak luminosity of 8 ×1033cm-2s-1. During the next run, peak luminosities of 1.5 ×1034cm-2s-1 and even higher are expected at a 25 ns bunch spacing. Such a high collision rate may have an impact on the quality of the energy reconstruction which is attempted to be maintained at a high level using a calibration procedure described in this contribution. It also poses major challenges to the first level of the trigger system which is constrained to a maximal rate of 100 kHz. For Run-3, scheduled to start in 2019, instantaneous luminosity as high as 3 ×1034cm-2s-1 are foreseen imposing an upgrade of the LAr trigger system to maintain its performance. A demonstrator containing prototypes of the upgraded trigger electronic architecture has been installed on one of the barrel electromagnetic calorimeter readout front end crates to test it during the Run-2 campaign. The new architecture and its benefits for data taking will be discussed below as well as the results from first beam splash events.

  16. Improvement of the technique of identification of electrons and positrons with use of electromagnetic calorimeter of the CLAS detector

    SciTech Connect

    Gevorgyan, N. E.; Dashyan, N. B.; Paremuzyan, R. G.; Stepanyan, S. G.

    2010-01-01

    We study the dependence of the sensitivity of response of the electromagnetic calorimeter of CLAS plant on the momenta of electrons and positrons. We made calculation of this dependence and elaborated a method for its employment in identification of e- and e+. We have shown that the new method of selection of e- and e+ improves the quality of identification by about 10%. We used the experimental data obtained with the plant CLAS of linear accelerator at Jefferson laboratory (USA).

  17. T-1018 UCLA Spacordion Tungsten Powder Calorimeter

    SciTech Connect

    Trentalange, Stephen; Tsai, Oleg; Igo, George; Huang, Huan; Pan, Yu Xi; Dunkelberger, Jay; Xu, Wen Qin; Soha, Aria; Heppelmann, Steven; Gagliardi, Carl; /Texas A-M

    2011-11-16

    The present experiments at the BNL-RHIC facility are evolving towards physics goals which require the detection of medium energy electromagnetic particles (photons, electrons, neutral pions, eta mesons, etc.), especially at forward angles. New detectors will place increasing demands on energy resolution, hadron rejection and two-photon resolution and will require large area, high performance electromagnetic calorimeters in a variety of geometries. In the immediate future, either RHIC or JLAB will propose a facility upgrade (Electron-Ion Collider, or EIC) with physics goals such as electron-heavy ion collisions (or p-A collisions) with a wide range of calorimeter requirements. An R and D program based at Brookhaven National Laboratory has awarded the group funding of approximately $110,000 to develop new types of calorimeters for EIC experiments. The UCLA group is developing a method to manufacture very flexible and cost-effective, yet high quality calorimeters based on scintillating fibers and tungsten powder. The design and features of the calorimeter can be briefly stated as follows: an arbitrarily large number of small diameter fibers (< 0.5 mm) are assembled as a matrix and held rigidly in place by a set of precision screens inside an empty container. The container is then back-filled with tungsten powder, compacted on a vibrating table and infused with epoxy under vacuum. The container is then removed. The resulting sub-modules are extremely uniform and achieve roughly the density of pure Lead. The sub-modules are stacked together to achieve a final detector of the desired shape. There is no dead space between sub-modules and the fibers can be in an accordion geometry bent to prevent 'channeling' of the particles due to accidental alignment of their track with the module axis. This technology has the advantage of being modular and inexpensive to the point where the construction work may be divided among groups the size of typical university physics departments

  18. Preparing the hardware of the CMS Electromagnetic Calorimeter control and safety systems for LHC Run 2

    NASA Astrophysics Data System (ADS)

    Holme, O.; Adzic, P.; Di Calafiori, D.; Cirkovic, P.; Dissertori, G.; Djambazov, L.; Jovanovic, D.; Lustermann, W.; Zelepoukine, S.

    2016-01-01

    The Detector Control System of the CMS Electromagnetic Calorimeter has undergone significant improvements during the first LHC Long Shutdown. Based on the experience acquired during the first period of physics data taking of the LHC, several hardware projects were carried out to improve data accuracy, to minimise the impact of failures and to extend remote control possibilities in order to accelerate recovery from problematic situations. This paper outlines the hardware of the detector control and safety systems and explains in detail the requirements, design and commissioning of the new hardware projects.

  19. Mechanical and thermal design of the CEBAF Hall a beam calorimeter

    SciTech Connect

    M. Bevins; A. Day; P. Degtiarenko; L.A. Dillon-Townes; A. Freyberger; R. Gilman; A. Saha; S. Slachtouski

    2005-05-16

    A calorimeter is being fabricated to provide 0.5% - 1.0% absolute measurement of the beam current in the Hall A end station of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (JLAB). Modern powder metallurgy processes have produced high density, high thermal conductivity tungsten-copper composite materials that minimize electromagnetic and hadronic energy loss while maintaining a rapid thermal response time. Heat leaks are minimized by mounting the mass in vacuum on glass ceramic mounts. A conduction cooling scheme utilizes an advanced carbon fiber compliant thermal interface material. Transient finite difference and finite element models were developed to estimate heat leaks and thermal response times.

  20. The Effect of Maternal Relaxation Training on Reactivity of Non-Stress Test, Basal Fetal Heart Rate, and Number of Fetal Heart Accelerations: A Randomized Controlled Trial

    PubMed Central

    Akbarzade, Marzieh; Rafiee, Bahare; Asadi, Nasrin; Zare, Najaf

    2015-01-01

    Background: Relaxation-training, as an anxiety-reducer intervention, plays an important role in fetal health. The present study aimed to analyze the effect of maternal relaxation on stress test (NST), basal fetal heart rate, and number of fetal heart accelerations. Methods: In this randomized controlled trial, 84 pregnant women were randomly divided into two groups of teaching relaxation and control groups in 2012. In the intervention group, 60-90 minute classes were held every week lasting for 4 weeks. Besides, home practice charts were given to the mothers and researchers controlled the home practices by phone calls every week. The control group received routine prenatal care. In the 4th week, NST was performed in the intervention group 30 minutes before and after the 4th session. In the control group, NST was done in the 4th week. The quantitative variables in the two groups were compared through ANOVA and Chi-square test. Results: The results of paired t-test showed that relaxation could improve the NST results (P=0.01). Mean and standard deviation of basal fetal heart rate was 138.95±8.18 before the intervention and 133.07±6.9 after the intervention. Paired t-test also showed that relaxation reduced the basal fetal heart rate (P=0.001). Mean and standard deviation of the number of fetal heart accelerations was 1.5±0.8 before the intervention and 2.2±0.9 after it. The results of paired t-test also showed that relaxation increased the number of fetal heart accelerations (P=0.001). Conclusions: Relaxation could improve the NST results, reduce the basal fetal heart rate, and increase the number of fetal heart accelerations. Therefore, relaxation is recommended during pregnancy. Trial Registration Number: IRCT2012072810418N1 PMID:25553334

  1. Proportional wire calorimeter for magnet pole tips

    SciTech Connect

    Kraus, D; Ludlam, T; Renardy, J; Willis, W; Zurfluh, E

    1980-01-01

    A total absorption calorimeter is designed to have magnetic properties comparable to those of ordinary steel, and thus can be incorporated into the poles of a spectrometer magnet without compromising the field quality. A test device has been built which consists of an iron structure penetrated by a finegrain pattern of holes, each acting as a proportional tube such that 90% of the volume is occupied by iron. Measurements of the energy and space resolution of this device in a high energy beam will be presented.

  2. The simulation of the CMS electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Cossutti, F.

    2008-07-01

    The CMS Collaboration has developed a detailed simulation of the electromagnetic calorimeter (ECAL), which has been fully integrated in the collaboration software framework CMSSW. The simulation is based on the Geant4 detector simulation toolkit for the modelling of the passage of particles through matter and magnetic field. The geometrical description of the detector is being re-implemented using the DetectorDescription language, combining an XML based description with the algorithmic definition of the position of the elements. The ECAL simulation software is fully operational and has been validated using real data from the ECAL test beam experiment that took place in summer 2006.

  3. Calorimeter measurements of low wattage items

    SciTech Connect

    Cremers, T.L.; Camp, K.L.; Hildner, S.S.; Sedlacek, W.A.

    1993-08-01

    The transition of DOE facilities from production to decontamination and decommissioning has led to more measurements of waste, scrap, and other less attractive materials. The difficulty that these materials pose for segmented gamma scanning and neutron counting has increased the use of calorimetric assay for very low wattage items (< 250 millwatts). We have measured well characterized {sup 238}Pu oxide ranging in wattage from 25 to 500 milliwatts in the calorimeters at the Los Alamos Plutonium Facility and report the error and the precision of the measurements.

  4. Isothermal drop calorimeter provides measurements for alpha active, pyrophoric materials

    NASA Technical Reports Server (NTRS)

    Savage, H.

    1969-01-01

    Isothermal drop calorimeter measures the heat content of intensely alpha active and pyrophoric materials in inert atmospheres. It consists of a furnace, calorimeter, and aluminum isothermal jacket contained within an inert-atmosphere glove box, which permits the use of unencapsulated materials without exposing personnel to alpha contamination.

  5. Ac loss calorimeter for three-phase cable

    SciTech Connect

    Daney, D.E.; Boenig, H.J.; Maley, M.P.; McMurry, D.E.; DeBlanc, B.G.

    1996-10-01

    A calorimeter for measuring ac losses in meter-long lengths of HTS superconducting power transmission line cables is described. The calorimeter, which is based on a temperature difference technique, has a precision of 1 mW and measures single, two-phase (coupling), and three-phase losses. The measurements show significant coupling losses between phases.

  6. A study of the influence of the data acquisition system sampling rate on the accuracy of measured acceleration loads for transport aircraft

    NASA Technical Reports Server (NTRS)

    Whitehead, Julia H.

    1992-01-01

    A research effort was initiated at National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC), to describe the relationship between the sampling rate and the accuracy of acceleration loads obtained from the data acquisition system of a transport aircraft. An accelerometer was sampled and digitized at a rate of 100 samples per second onboard a NASA Boeing 737 (B-737) flight research aircraft. Numerical techniques were used to reconstruct 2.5 hours of flight data into its original input waveform and then re-sample the waveform into rates of 4, 8, 16, and 32 samples per second. Peak-between-means counting technique and power spectral analysis were used to evaluate each sampling rate using the 32 samples per second data as the comparison. This paper presents the results from these methods and includes in appendix A, the peak-between-means counting results used in a general fatigue analysis for each of the sampling rates.

  7. The electromagnetic calorimeter for the T2K near detector ND280

    NASA Astrophysics Data System (ADS)

    Allan, D.; Andreopoulos, C.; Angelsen, C.; Barker, G. J.; Barr, G.; Bentham, S.; Bertram, I.; Boyd, S.; Briggs, K.; Calland, R. G.; Carroll, J.; Cartwright, S. L.; Carver, A.; Chavez, C.; Christodoulou, G.; Coleman, J.; Cooke, P.; Davies, G.; Densham, C.; Di Lodovico, F.; Dobson, J.; Duboyski, T.; Durkin, T.; Evans, D. L.; Finch, A.; Fitton, M.; Gannaway, F. C.; Grant, A.; Grant, N.; Grenwood, S.; Guzowski, P.; Hadley, D.; Haigh, M.; Harrison, P. F.; Hatzikoutelis, A.; Haycock, T. D. J.; Hyndman, A.; Ilic, J.; Ives, S.; Kaboth, A. C.; Kasey, V.; Kellet, L.; Khaleeq, M.; Kogan, G.; Kormos, L. L.; Lawe, M.; Lawson, T. B.; Lister, C.; Litchfield, R. P.; Lockwood, M.; Malek, M.; Maryon, T.; Masliah, P.; Mavrokoridis, K.; McCauley, N.; Mercer, I.; Metelko, C.; Morgan, B.; Morris, J.; Muir, A.; Murdoch, M.; Nicholls, T.; Noy, M.; O'Keeffe, H. M.; Owen, R. A.; Payne, D.; Pearce, G. F.; Perkin, J. D.; Poplawska, E.; Preece, R.; Qian, W.; Ratoff, P.; Raufer, T.; Raymond, M.; Reeves, M.; Richards, D.; Rooney, M.; Sacco, R.; Sadler, S.; Schaack, P.; Scott, M.; Scully, D. I.; Short, S.; Siyad, M.; Smith, R.; Still, B.; Sutcliffe, P.; Taylor, I. J.; Terri, R.; Thompson, L. F.; Thorley, A.; Thorpe, M.; Timis, C.; Touramanis, C.; Uchida, M. A.; Uchida, Y.; Vacheret, A.; Van Schalkwyk, J. F.; Veledar, O.; Waldron, A. V.; Ward, M. A.; Ward, G. P.; Wark, D.; Wascko, M. O.; Weber, A.; West, N.; Whitehead, L. H.; Wilkinson, C.; Wilson, J. R.

    2013-10-01

    The T2K experiment studies oscillations of an off-axis muon neutrino beam between the J-PARC accelerator complex and the Super-Kamiokande detector. Special emphasis is placed on measuring the mixing angle θ13 by observing νe appearance via the sub-dominant νμ → νe oscillation and searching for CP violation in the lepton sector. The experiment includes a sophisticated, off-axis, near detector, the ND280, situated 280 m downstream of the neutrino production target in order to measure the properties of the neutrino beam and to understand better neutrino interactions at the energy scale below a few GeV. The data collected with the ND280 are used to study charged- and neutral-current neutrino interaction rates and kinematics prior to oscillation, in order to reduce uncertainties in the oscillation measurements by the far detector. A key element of the near detector is the ND280 electromagnetic calorimeter (ECal), consisting of active scintillator bars sandwiched between lead sheets and read out with multi-pixel photon counters (MPPCs). The ECal is vital to the reconstruction of neutral particles, and the identification of charged particle species. The ECal surrounds the Pi-0 detector (PØD) and the tracking region of the ND280, and is enclosed in the former UA1/NOMAD dipole magnet. This paper describes the design, construction and assembly of the ECal, as well as the materials from which it is composed. The electronic and data acquisition (DAQ) systems are discussed, and performance of the ECal modules, as deduced from measurements with particle beams, cosmic rays, the calibration system, and T2K data, is described.

  8. Design of Refractory Metal Life Test Heat Pipe and Calorimeter

    NASA Technical Reports Server (NTRS)

    Martin, J. J.; Reid, R. S.; Bragg-Sitton, S. M.

    2010-01-01

    Heat pipe life tests have seldom been conducted on a systematic basis. Typically, one or more heat pipes are built and tested for an extended period at a single temperature with simple condenser loading. Results are often reported describing the wall material, working fluid, test temperature, test duration, and occasionally the nature of any failure. Important information such as design details, processing procedures, material assay, power throughput, and radial power density are usually not mentioned. We propose to develop methods to generate carefully controlled data that conclusively establish heat pipe operating life with material-fluid combinations capable of extended operation. The test approach detailed in this Technical Publication will use 16 Mo-44.5%Re alloy/sodium heat pipe units that have an approximate12-in length and 5/8-in diameter. Two specific test series have been identified: (1) Long-term corrosion rates based on ASTM-G-68-80 (G-series) and (2) corrosion trends in a cross-correlation sequence at various temperatures and mass fluences based on a Fisher multifactor design (F-series). Evaluation of the heat pipe hardware will be performed in test chambers purged with an inert purified gas (helium or helium/argon mixture) at low pressure (10-100 torr) to provide thermal coupling between the heat pipe condenser and calorimeter. The final pressure will be selected to minimize the potential for voltage breakdown between the heat pipe and radio frequency (RF) induction coil (RF heating is currently the planned method of powering the heat pipes). The proposed calorimeter is constructed from a copper alloy and relies on a laminar flow water-coolant channel design to absorb and transport energy

  9. Ullmann diaryl ether synthesis: rate acceleration by 2,2,6,6-tetramethylheptane-3,5-dione.

    PubMed

    Buck, Elizabeth; Song, Zhiguo Jake; Tschaen, David; Dormer, Peter G; Volante, R P; Reider, Paul J

    2002-05-02

    [reaction: see text]. In the copper salt catalyzed ether formation from aryl bromides or iodides and phenols, 2,2,6,6-tetramethylheptane-3,5-dione (TMHD) was found to greatly accelerate the ordinarily difficult reaction, making it occur under more moderate temperatures and reaction times. A series of aryl halides and phenols were shown to form ethers in NMP as the solvent, cesium carbonate as the base, and CuCl and TMHD as the catalysts. The reaction was shown to tolerate electron-rich aryl bromides and electron-neutral phenols.

  10. Accelerated second-degree nursing students: predictors of graduation and NCLEX-RN first-time pass rates.

    PubMed

    Penprase, Barbara B; Harris, Margaret A

    2013-01-01

    It is important to understand and identify factors that affect students' academic performance before entry into a nursing program and as they progress through the program. The authors discuss a study, and its outcomes, that assessed accelerated second-degree nursing students' prenursing and core nursing grades that served to predict their success at completing the nursing program and passing NCLEX-RN on first attempt. Strategies were identified to help at-risk students to be successful in the program and with first-time passage of NCLEX-RN.

  11. High-sensitivity microfluidic calorimeters for biological and chemical applications

    PubMed Central

    Lee, Wonhee; Fon, Warren; Axelrod, Blake W.; Roukes, Michael L.

    2009-01-01

    High-sensitivity microfluidic calorimeters raise the prospect of achieving high-throughput biochemical measurements with minimal sample consumption. However, it has been challenging to realize microchip-based calorimeters possessing both high sensitivity and precise sample-manipulation capabilities. Here, we report chip-based microfluidic calorimeters capable of characterizing the heat of reaction of 3.5-nL samples with 4.2-nW resolution. Our approach, based on a combination of hard- and soft-polymer microfluidics, provides both exceptional thermal response and the physical strength necessary to construct high-sensitivity calorimeters that can be scaled to automated, highly multiplexed array architectures. Polydimethylsiloxane microfluidic valves and pumps are interfaced to parylene channels and reaction chambers to automate the injection of analyte at 1 nL and below. We attained excellent thermal resolution via on-chip vacuum encapsulation, which provides unprecedented thermal isolation of the minute microfluidic reaction chambers. We demonstrate performance of these calorimeters by resolving measurements of the heat of reaction of urea hydrolysis and the enthalpy of mixing of water with methanol. The device structure can be adapted easily to enable a wide variety of other standard calorimeter operations; one example, a flow calorimeter, is described. PMID:19706406

  12. Upgrade of the ATLAS Tile hadronic calorimeter for high-luminosity LHC run

    NASA Astrophysics Data System (ADS)

    Spoor, Matthew

    2017-02-01

    The ATLAS Tile Calorimeter (TileCal) will undergo a major replacement of its on- and off-detector electronics for the Long Shutdown 3 that is planned for 2024 and 2025. All signals will be digitised and transferred directly to the off-detector electronics, where the signals are reconstructed, stored, and sent to the first level of trigger at a rate of 40 MHz. This will provide better precision of the calorimeter signals used by the trigger system and will allow the development of more complex trigger algorithms. Changes to the electronics will also contribute to the reliability and redundancy of the system. Three different front-end options are presently being investigated for the upgrade and will be chosen after extensive test beam studies. A Hybrid Demonstrator module has been developed. The demonstrator is undergoing extensive testing and is planned for insertion in ATLAS.

  13. Moving towards acceleration for estimates of activity-specific metabolic rate in free-living animals: the case of the cormorant.

    PubMed

    Wilson, Rory P; White, Craig R; Quintana, Flavio; Halsey, Lewis G; Liebsch, Nikolai; Martin, Graham R; Butler, Patrick J

    2006-09-01

    1. Time and energy are key currencies in animal ecology, and judicious management of these is a primary focus for natural selection. At present, however, there are only two main methods for estimation of rate of energy expenditure in the field, heart rate and doubly labelled water, both of which have been used with success; but both also have their limitations. 2. The deployment of data loggers that measure acceleration is emerging as a powerful tool for quantifying the behaviour of free-living animals. Given that animal movement requires the use of energy, the accelerometry technique potentially has application in the quantification of rate of energy expenditure during activity. 3. In the present study, we test the hypothesis that acceleration can serve as a proxy for rate of energy expenditure in free-living animals. We measured rate of energy expenditure as rates of O2 consumption (VO2) and CO2 production (VCO2) in great cormorants (Phalacrocorax carbo) at rest and during pedestrian exercise. VO2 and VCO2 were then related to overall dynamic body acceleration (ODBA) measured with an externally attached three-axis accelerometer. 4. Both VO2 and VCO2 were significantly positively associated with ODBA in great cormorants. This suggests that accelerometric measurements of ODBA can be used to estimate VO2 and VCO2 and, with some additional assumptions regarding metabolic substrate use and the energy equivalence of O2 and CO2, that ODBA can be used to estimate the activity specific rate of energy expenditure of free-living cormorants. 5. To verify that the approach identifies expected trends in from situations with variable power requirements, we measured ODBA in free-living imperial cormorants (Phalacrocorax atriceps) during foraging trips. We compared ODBA during return and outward foraging flights, when birds are expected to be laden and not laden with captured fish, respectively. We also examined changes in ODBA during the descent phase of diving, when power

  14. Method and system for improved resolution of a compensated calorimeter detector

    DOEpatents

    Dawson, John W.

    1991-01-01

    An improved method and system for a depleted uranium calorimeter detector used in high energy physics experiments. In a depleted uranium calorimeter detector, the energy of a particle entering the calorimeter detector is determined and the output response of the calorimeter detector is compensated so that the ratio of the integrated response of the calorimeter detector from a lepton to the integrated response of the calorimeter detector from a hadron of the same energy as the lepton is approximately equal to 1. In the present invention, the energy of a particle entering the calorimeter detector is determined as a function of time and the hadron content of the response of the calorimeter detector is inferred based upon the time structure of the energy pulse measured by the calorimeter detector. The energy measurement can be corrected based on the inference of the hadron content whereby the resolution of the calorimeter can be improved.

  15. Electronics development for the ATLAS liquid argon calorimeter trigger and readout for future LHC running

    NASA Astrophysics Data System (ADS)

    Hopkins, Walter

    2017-02-01

    The upgrade of the LHC will provide 7 times greater instantaneous and 10 times greater total luminosities than assumed in the original design of the ATLAS Liquid Argon (LAr) Calorimeters. Radiation tolerance criteria and an improved trigger system with higher acceptance rate and longer latency require an upgrade of the LAr readout electronics. In the first upgrade phase in 2019-2020, a trigger readout with up to 10 times higher granularity will be implemented. This allows an improved reconstruction of electromagnetic and hadronic showers and will reduce the background for electron, photon and energy-flow signals at the first trigger level. The analog and digital signal processing components are currently in their final design stages and a fully functional demonstrator system is operated and tested on the LAr Calorimeters. In a second upgrade stage in 2024-2026, the readout of all 183,000 LAr Calorimeter cells will be performed without trigger selection at 40 MHz sampling rate and 16 bit dynamic range. Calibrated energies of all cells will be available at the second trigger level operating at 1 MHz, in order to allow further mitigation of pile-up effects in energy reconstruction. Radiation tolerant, low-power front-end electronics optimized for high pile-up conditions are currently being developed, including pre-amplifier, ADC and serializer components in 65-180 nm technology. This contribution will give an overview of the future LAr readout electronics and present research results from the two upgrade programs.

  16. Biological Manipulation of Migration Rate: The Use of Advanced Photoperiod to Accelerate Smoltification in Yearling Chinook Salmon, Annual Report 1989.

    SciTech Connect

    Giorgi, Albert E.; Muir, William D.; Zaugg, Waldo S.

    1991-01-01

    Research was conducted to assess the feasibility of biologically manipulating physiological development and migratory behavior of yearling spring chinook salmon, Oncorhynchus tshawytscha. At Dworshak National Fish Hatchery, treatment groups were exposed to a variety of advanced photoperiod cycles preceding release to accelerate smolt development. Physiological development and migratory performance were described for all groups. The treatments included a 14-week exposure to a 3-month advanced photoperiod cycle, an 18-week exposure to a 3-month advanced photoperiod cycle, and an 18-week exposure to a 4-month advanced photoperiod cycle. Two additional groups, an 18-week exposure to a 3-month advanced photoperiod and a control equivalent, were reared at an elevated water temperature (11{degrees}C) for 2 weeks prior to release. Results indicated that the treated fish which were the most physiologically advanced at release were detected in the highest proportion at collector dams and also migrated fastest downstream. 26 refs., 10 figs., 5 tabs.

  17. Data Analysis for the Scintillating Optical Fiber Calorimeter (SOFCAL)

    NASA Technical Reports Server (NTRS)

    Christl, Mark J.

    1997-01-01

    The scintillating optical fiber calorimeter is a hybrid instrument with both active and passive components for measuring the proton and helium cosmic ray spectra from 0.2 to IO TeV kinetic energy. A thin emulsion/x-ray film chamber is situated between a cerenkov counter and an imaging calorimeter. Scintillating optical fibers sample the electromagnetic showers that develop in the calorimeter and identify the trajectory of cosmic rays that interact in SOFCAL. The emulsion/x-ray film data provide an in flight calibration for SOFCAL. The data reduction techniques used will be discussed and interim results of the analysis from a 20 hour balloon flight will be presented.

  18. New tools for the simulation and design of calorimeters

    SciTech Connect

    Womersley, W.J.

    1989-07-10

    Two new approaches to the simulation and design of large hermetic calorimeters are presented. Firstly, the Shower Library scheme used in the fast generation of showers in the Monte Carlo of the calorimeter for the D-Zero experiment at the Fermilab Tevatron is described. Secondly, a tool for the design future calorimeters is described, which can be integrated with a computer aided design system to give engineering designers an immediate idea of the relative physics capabilities of different geometries. 9 refs., 6 figs., 1 tab.

  19. Optical System of the STAR Barrel Electromagnetic Calorimeter

    NASA Astrophysics Data System (ADS)

    Grachov, O. A.

    2000-04-01

    The STAR Barrel Electromagnetic Calorimeter(BEMC) is a sampling calorimeter and the core of structure consist of a lead-scintillator plate stack. The plastic scintillator in the form of Mega-tile with 40 optically isolated tiles in each layer. The tile/fiber system uses a wavelength shifting fiber to read out the signal of a tile and a optical clear fiber carry the light through the magnet structure to the electronic-PMT box. A discription of the Optical system of BEMC is presented along with a current status of the quality control program of the calorimeter production.

  20. D0 Silicon Upgrade: End Calorimeter Transfer Bridge Modification

    SciTech Connect

    Stredde, H.J.; /Fermilab

    1996-07-10

    During the assembly of major components into the D0 Detector, a transfer bridge was required to move the North-End Calorimeter from the clean room,over the cable bridge and onto the north sidewalk of the assembly hall. This experiment is now at the beginning stages of the next phase, namely the upgrade of this Detector for future physics research. A major piece of this upgrade is the installation of a solenoid magnet into the Central Calorimeter. In order to accomplish this, the South End Calorimeter has to be removed from the detector and the North End Calorimeter must be moved an additional 20-inch from its nominal open position (total 60-inch movement). The South End Calorimeter will be removed from the detector using the equipment designed for its installation. The calorimeter will be staged on the south sidewalk during the installation of the solenoid magnet and the central tracking systems. The North End Calorimeter is moved 60-inch to give more space between calorimeters during magnet, tracker and cable installation work. This movement will allow the calorimeter to remain coupled to the cryo system. However, this movement requires an extension be added to the center beam. This extension will support the rear wheels of the calorimeter and in the case of the end calorimeters, carry the majority of the weight. The extension is to be a modification of the transfer bridge. This modification, basically has T1 steel blocks added to one end and legs to the sidewalk supports at the other. The T1 steel blocks are notched to fit into the center beam porches and are welded to bridge rails. This design is the same as that for the installation bridge (3740.312-ME-273456), including the welds and weld procedures which are identical in both cases. Since load testing is impractical, the critical welds will be non-destructive tested by ultrasonic means. The laboratory, through the FESS Department, has a contract with M.Q.S. Inspection Inc. The results of this testing will be

  1. sPHENIX Calorimeter Design and Jet Performance

    SciTech Connect

    Haggerty J. S.

    2016-09-27

    The PHENIX collaboration is planning a detector upgrade, sPHENIX, which consists of large acceptance calorimetry and tracking detectors built around the superconducting solenoid recently shipped to Brookhaven from the decommissioned BaBar experiment at SLAC. The sPHENIX calorimeter system includes three radial layers of samplingcalorimeters, a tungsten-scintillating fiber electromagnetic calorimeter, and two longitudinally segmented samplinghadron calorimeters that are made of scintillator tiles and steel plates. Together, they provide hermetic coverage in n < 1 for calorimetry based jet measurements as well as minimal bias jet trigger capability, which coupled with high resolution tracking, enable an extremely rich jet physics program at RHIC.

  2. On the Challenge of Keeping ATLAS Tile Calorimeter Raw Data

    NASA Astrophysics Data System (ADS)

    Tsiskaridze, V. K.

    2012-08-01

    The Tile Calorimeter (TileCal) for the ATLAS experiment at the CERN Large Hadron Collider (LHC) is currently taking data with proton-proton collisions. The TileCal read-out system was initially designed to reconstruct the data in real-time and to store for each channel the signal amplitude, time and quality factor at the required high rate. This approach implied discarding 80% of the raw data that correspond to noise or small signals. Practical experience operating in this scheme with increasing rate have led to several modifications and understanding that some kind of data compression is helpful during data processing and storing. An alternate approach is to use online reconstruction for Level 2 triggering only and to implement a data flow lossless compression scheme for further offiine analysis. A new version of the lossless compression algorithm is proposed which allows to both save the complete raw data and to feed the trigger with the reconstructed signal amplitude and time. It does not increase the data flow as compared to the existing approach and the size of the data fragments transmitted is more stable. We will describe the lossless compression algorithm as a possible upgrade of the Tile data acquisition and highlight some details of the implementation. We will report on its testing and validation and on the overall performance measured on high rate tests, calibration and √ {s} = 7 TeV proton-proton collisions runs.

  3. Trigger circuits for the PHENIX electromagnetic calorimeter

    SciTech Connect

    Frank, S.S.; Britton, C.L. Jr.; Winterberg, A.L.; Young, G.R.

    1997-11-01

    Monolithic and discrete circuits have been developed to provide trigger signals for the PHENIX electromagnetic calorimeter detector. These trigger circuits are deadtimeless and create overlapping 4 by 4 energy sums, a cosmic muon trigger, and a 144 channel energy sum. The front end electronics of the PHENIX system sample the energy and timing channels at each bunch crossing (BC) but it is not known immediately if this data is of interest. The information from the trigger circuits is used to determine if the data collected is of interest and should be digitized and stored or discarded. This paper presents details of the design, issues affecting circuit performance, characterization of prototypes fabricated in 1.2 {micro}m Orbit CMOS, and integration of the circuits into the EMCal electronics system.

  4. Calorimeter Simulation with Hadrons in CMS

    SciTech Connect

    Piperov, Stefan; /Sofiya, Inst. Nucl. Res. /Fermilab

    2008-11-01

    CMS is using Geant4 to simulate the detector setup for the forthcoming data from the LHC. Validation of physics processes inside Geant4 is a major concern in view of getting a proper description of jets and missing energy for signal and background events. This is done by carrying out an extensive studies with test beam using the prototypes or real detector modules of the CMS calorimeter. These data are matched with Geant4 predictions using the same framework that is used for the entire CMS detector. Tuning of the Geant4 models is carried out and steps to be used in reproducing detector signals are defined in view of measurements of energy response, energy resolution, transverse and longitudinal shower profiles for a variety of hadron beams over a broad energy spectrum between 2 to 300 GeV/c. The tuned Monte Carlo predictions match many of these measurements within systematic uncertainties.

  5. Parametric study of the energy deposition inside the calorimeter measuring the nuclear heating in Material Testing Reactors

    NASA Astrophysics Data System (ADS)

    Amharrak, H.; Reynard-Carette, C.; Lyoussi, A.; Carette, M.; Brun, J.; De Vita, C.; Fourmentel, D.; Villard, J.-F.

    2015-11-01

    The nuclear heating measurements in Material Testing Reactors (MTRs) are crucial for the study of nuclear materials and fuels under irradiation. The reference measurements of this nuclear heating are especially performed by a differential calorimeter including a graphite sample material and two calorimetric cells. Then these measurements are used for other experimental conditions in order to predict the nuclear heating and thermal conditions induced in the irradiation devices. This paper will present simulations with MCNP5 Monte-Carlo transport code (using ENDF/B-VI nuclear data library) to evaluate the nuclear heating inside the calorimeter during irradiation campaigns of the CARMEN-1P mock-up inside OSIRIS reactor periphery (MTR based on Saclay, France). The whole complete geometry of the sensor has been considered. The calculation method corresponds to a calculation in two steps. Consequently, we used as an input source in the model, the neutron and photon spectra calculated in various experimental locations tested during the irradiation campaign (H9, H10, H11, D9). After a description of the differential calorimeter sensor, the MCNP5 model used for the calculations of nuclear heating inside the calorimeter elements is introduced by two quantities: KERMA and energy deposition rate per mass unit. The Charged Particle Equilibrium (CPE) inside the calorimeter elements is studied. The contribution of prompt gamma and neutron is determined. A comparison between this total nuclear heating calculation and the experimental results in a graphite sample will be made. Then parametric studies performed on the influence of the various calorimeter components on the nuclear heating are presented and discussed. The studies of the influence of the nature of materials, the sensor jacket, the source type and the comparison of the results obtained for the two calorimetric cells leads to some proposals for the sensor improvement.

  6. Exact solution to the general Riemann problem in nonuniform and nonstationary media: A simplified analysis of a shock wave accelerated at a constant rate

    NASA Astrophysics Data System (ADS)

    Mori, Koichi

    2010-12-01

    Exact solutions to special cases of the general Riemann problem, in which two nonuniform and nonstationary flows are initially separated by a discontinuity at the origin, are proposed. By describing the evolution of flows using a family of the group-invariant solutions derived by Ovsiannikov [Dokl. Akad. Nauk S.S.S.R. 111, 439 (1958)] the flows ahead of and behind a shock wave accelerated at a constant rate are formulated analytically. Transition relations across a contact discontinuity and a characteristic wave in a nonuniform and nonstationary flow are formulated as well. The entire flow field is solved by combining these waves.

  7. Linear Accelerators

    NASA Astrophysics Data System (ADS)

    Sidorin, Anatoly

    2010-01-01

    In linear accelerators the particles are accelerated by either electrostatic fields or oscillating Radio Frequency (RF) fields. Accordingly the linear accelerators are divided in three large groups: electrostatic, induction and RF accelerators. Overview of the different types of accelerators is given. Stability of longitudinal and transverse motion in the RF linear accelerators is briefly discussed. The methods of beam focusing in linacs are described.

  8. The need for speed: testing acceleration for estimating animal travel rates in terrestrial dead-reckoning systems.

    PubMed

    Bidder, Owen R; Soresina, Marion; Shepard, Emily L C; Halsey, Lewis G; Quintana, Flavio; Gómez-Laich, Agustina; Wilson, Rory P

    2012-02-01

    Numerous methods are currently available to track animal movements. However, only one of these, dead-reckoning, has the capacity to provide continuous data for animal movements over fine scales. Dead-reckoning has been applied almost exclusively in the study of marine species, in part due to the difficulty of accurately measuring the speed of terrestrial species. In the present study we evaluate the use of accelerometers and a metric known as overall dynamic body acceleration (ODBA) as a proxy for the measurement of speed for use in dead-reckoning. Data were collated from previous studies, for 10 species locomoting on a treadmill and their ODBA measured by an attached data logger. All species except one showed a highly significant linear relationship between speed and ODBA; however, there was appreciable inter- and intra-specific variance in this relationship. ODBA was then used to estimate speed in a simple trial run of a dead-reckoning track. Estimating distance travelled using speed derived from prior calibration for ODBA resulted in appreciable errors. We describe a method by which these errors can be minimised, by periodic ground-truthing (e.g., by GPS or VHF telemetry) of the dead-reckoned track and adjusting the relationship between speed and ODBA until actual known positions and dead-reckoned positions accord.

  9. Calibration of a digital hadron calorimeter with muons

    SciTech Connect

    Bilki, Burak; Butler, John; Cundiff, Tim; Drake, Gary; Haberichter, William; Hazen, Eric; Hoff, Jim; Holm, Scott; Kreps, Andrew; May, Ed; Mavromanolakis, Georgios; /Fermilab /Iowa U. /Argonne /Boston U. /Argonne, PHY

    2008-02-01

    The calibration procedure of a finely granulated digital hadron calorimeter with Resistive Plate Chambers as the active elements is described. Results obtained with a stack of nine layers exposed to muons from the Fermilab test beam are presented.

  10. The BaBar cesium iodide electromagnetic calorimeter

    SciTech Connect

    Wuest, C.R.

    1994-12-01

    The BABAR Cesium Iodide Electromagnetic Calorimeter is currently in the technical design stage. The calorimeter consists of approximately 10,000 individual thallium-doped cesium iodide crystals arranged in a near-hermetic barrel and endcap structure. Taking previous cesium iodide calorimeters as a benchmark, we hope to build a system with roughly two times better energy resolution. This will be achieved by a combination of high quality crystal growing, precision mechanical processing of crystals and support structure, highly efficient light collection and low noise readout electronics. The calorimeter described here represents the current state of the design and we are undertaking an active period of optimization before this design is finalized. We discuss here the physics motivation, the current design and options for optimization.

  11. The Forward Calorimeter of the GlueX Experiment

    NASA Astrophysics Data System (ADS)

    Bennett, Daniel; GlueX Collaboration

    2013-10-01

    The Forward Calorimeter (FCAL) of the GlueX experiment is a lead glass electromagnetic calorimeter currently being built in Hall D of Jefferson Lab. The GlueX experiment is a photoproduction experiment that will utilize coherent bremsstrahlung radiation to map out the light meson spectrum, including a search for hybrid mesons with exotic quantum numbers (JPC). The FCAL will detect photons between 1° and 10 .8° downstream from the target. The calorimeter is built out of 2800 elements, each of which consists of a lead glass block, an FEU 84-3 PMT, and a custom Cockcroft-Walton electronic base. In the Fall of 2011, a 25 element prototype detector was installed in Hall B of Jefferson Lab to measure the energy and timing resolution of the calorimeter using electrons between 100 and 250 MeV. The design and construction of FCAL and the results from the prototype test will be discussed.

  12. ATLAS Tile Calorimeter performance with Run 1 data

    NASA Astrophysics Data System (ADS)

    Cerdá Alberich, L.

    2016-07-01

    The performance of the central hadronic calorimeter, TileCal, in the ATLAS Experiment at the Large Hadron Collider is studied using cosmic-ray muons and the large sample of proton-proton collisions acquired during the Run 1 of LHC (2010-2012). Results are presented for the precision of the absolute energy scale and timing, noise characterization, and time-stability of the detector. The results show that the Tile Calorimeter performance is within the design requirements of the detector.

  13. Building and testing a high school calorimeter at CERN

    NASA Astrophysics Data System (ADS)

    Biesot, L.; Crane, R.; Engelen, M. A. G.; van Haren, A. M. A.; van Kleef, R. H. B.; Leenders, O. R.; Timmermans, C.

    2016-11-01

    We have designed, built and tested a crystal calorimeter in the context of CERN’s first beam line for schools competition. The results of the tests at CERN show that the light output of our calorimeter depends on the energy deposited by particles (electrons and muons) hitting the crystals. Our design can be reproduced by high schools around the world, as we have avoided the use of toxic chemicals.

  14. Vibration isolation system for cryogenic phonon-scintillation calorimeters

    NASA Astrophysics Data System (ADS)

    Lee, C.; Jo, H. S.; Kang, C. S.; Kim, G. B.; Kim, I.; Kim, S. R.; Kim, Y. H.; Lee, H. J.; So, J. H.; Yoon, Y. S.

    2017-02-01

    Cryogen-free dilution refrigerators are getting popular for rare event searches underground due to their advantages. However, the application of a pulse tube refrigerator introduces mechanical vibration that can translate into temperature fluctuation for calorimeters. The effect is significant in particular when the sensor is attached to a large absorber. A mechanical filter is installed to isolate the calorimeters from the vibration inside a cryogen-free dilution refrigerator while meeting thermal requirements.

  15. The electromagnetic calorimeter in JLab Real Compton Scattering Experiment

    SciTech Connect

    Albert Shahinyan; Eugene Chudakov; A. Danagoulian; P. Degtyarenko; K. Egiyan; V. Gorbenko; J. Hines; E. Hovhannisyan; Ch. Hyde; C.W. de Jager; A. Ketikyan; V. Mamyan; R. Michaels; A.M. Nathan; V. Nelyubin; I. Rachek; M. Roedelbrom; A. Petrosyan; R. Pomatsalyuk; V. Popov; J. Segal; Yu. Shestakov; J. Templon; H. Voskanyan; B. Wojtsekhowski

    2007-04-16

    A hodoscope calorimeter comprising of 704 lead-glass blocks is described. The calorimeter was constructed for use in the JLab Real Compton Scattering experiment. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6\\%/$\\sqrt{E_\\gamma \\, [GeV]}$, respectively. Design features and performance parameters during the experiment are presented.

  16. Current Status and Performance of the BESIII Electromagnetic Calorimeter

    NASA Astrophysics Data System (ADS)

    Feldbauer, Florian; BESIII Collaboration

    2015-02-01

    The BESIII experiment is located at the Beijing Electron Positron Collider (BEPCII) in China. Its electromagnetic calorimeter (EMC) consists of 6240 CsI(TI) crystals, each read out by two Photodiodes (PD) at the end of the crystal. Changes in the response of the calorimeter due to radiation damage in the crystals or changes in the photo detector output are monitored with a light pulser system.

  17. High Repetition Rate Electron Beam RF-Acceleration and Sub-Millimeter Wave Generation via a Free Electron Laser.

    DTIC Science & Technology

    1985-08-14

    the American Physical Society 29. 1180 (1984). (b) D.B. McDermott, W.J. Nunan and N.C. Luhmann. Jr.. "A High Repetition Rate. Compact Free Electron...Laser." to be published in Proc. of 1985 IEEE IEDM Meeting. (c) D.B. McDermott. W.J. Nunan and N.C. Luhmann. Jr.. "A High Repetition Rate. Compact Free...Electron Laser". to be published in Proc. of Tenth S Int. Conf. on IR and mm-Waves. tApI (d) W.3. Nunan . D.B. McDermott and N.C. Luhmann. Jr.. "A

  18. EMPIRICAL DETERMINATION OF THE ENERGY LOSS RATE OF ACCELERATED ELECTRONS IN A WELL-OBSERVED SOLAR FLARE

    SciTech Connect

    Torre, Gabriele; Pinamonti, Nicola; Guo, Jingnan; Piana, Michele; Emslie, A. Gordon; Massone, Anna Maria E-mail: pinamont@dima.unige.it E-mail: piana@dima.unige.it E-mail: annamaria.massone@cnr.it

    2012-06-01

    We present electron images of an extended solar flare source, deduced from RHESSI hard X-ray imaging spectroscopy data. We apply the electron continuity equation to these maps in order to determine empirically the form of the energy loss rate for the bremsstrahlung-emitting electrons. We show that this form is consistent with an energy transport model involving Coulomb collisions in a target with a temperature of about 2 Multiplication-Sign 10{sup 7} K, with a continuous injection of fresh deka-keV electrons at a rate of approximately 10{sup -2} electrons s{sup -1} per ambient electron.

  19. Performances of the signal reconstruction in the ATLAS Hadronic Tile Calorimeter

    NASA Astrophysics Data System (ADS)

    Meoni, E.

    2013-08-01

    The Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of ATLAS. It is a key detector for the reconstruction of hadrons, jets, tau leptons and missing transverse energy. TileCal is a sampling calorimeter using steel as an absorber and plastic scintillators as an active medium. The scintillators are read-out by wavelength shifting fibers coupled to photomultiplier tubes (PMTs). The analogue signals from the PMTs are amplified, shaped and digitized by sampling the signal every 25 ns. The read-out system is designed to reconstruct the data in real time fulfilling the tight time constraint imposed by the ATLAS first level trigger rate (100 kHz). The signal amplitude and phases for each channel are measured using Optimal Filtering algorithms both at online and offline level. We present the performances of these techniques on the data collected in the proton-proton collisions at center-of-mass energy of 7 TeV. We show in particular the measurements of low amplitudes, close to the pedestal value, using as probe high transverse momenta muons produced in the proton-proton collisions.

  20. An automated flow calorimeter for heat capacity and enthalpy measurements at elevated temperatures and pressures

    SciTech Connect

    Yesavage, V.F.

    1990-08-31

    The need for highly accurate thermal property data for a broad range of new application fluids is well documented. To facilitate expansion of the current thermophysical database, an automated flow calorimeter was developed for the measurement of highly accurate isobaric heat capacities and enthalpies of fluids at elevated temperatures and pressures. The experimental technique utilizes traditional electrical power input, adiabatic flow calorimetry with a precision metering pump that eliminates the need for on-line flow rate monitoring. In addition, a complete automation system, greatly simplifies the operation of the apparatus and increases the rapidity of the measurement process. The range over which the instrument was tested, was 300--600 K and 0--12 Mpa, although the calorimeter should perform up to the original design goals of 700 K and 30 MPa. The new flow calorimeter was evaluated by measuring the mean, isobaric, specific heat capacities of liquid water and n-pentane. These experiments yielded an average deviation from the standard literature data of +0.02% and a total variation of 0.05%. Additional data analysis indicated that the overall measurement uncertainty was conservatively estimated as 0.2% with an anticipated precision of 0.1--0.15% at all operating conditions. 44 refs., 27 figs., 2 tabs.

  1. Factors Associated With Chest Wall Toxicity After Accelerated Partial Breast Irradiation Using High-Dose-Rate Brachytherapy

    SciTech Connect

    Brown, Sheree; Vicini, Frank; Vanapalli, Jyotsna R.; Whitaker, Thomas J.; Pope, D. Keith; Lyden, Maureen; Bruggeman, Lisa; Haile, Kenneth L.; McLaughlin, Mark P.

    2012-07-01

    Purpose: The purpose of this analysis was to evaluate dose-volume relationships associated with a higher probability for developing chest wall toxicity (pain) after accelerated partial breast irradiation (APBI) by using both single-lumen and multilumen brachytherapy. Methods and Materials: Rib dose data were available for 89 patients treated with APBI and were correlated with the development of chest wall/rib pain at any point after treatment. Ribs were contoured on computed tomography planning scans, and rib dose-volume histograms (DVH) along with histograms for other structures were constructed. Rib DVH data for all patients were sampled at all volumes {>=}0.008 cubic centimeter (cc) (for maximum dose related to pain) and at volumes of 0.5, 1, 2, and 3 cc for analysis. Rib pain was evaluated at each follow-up visit. Patient responses were marked as yes or no. No attempt was made to grade responses. Eighty-nine responses were available for this analysis. Results: Nineteen patients (21.3%) complained of transient chest wall/rib pain at any point in follow-up. Analysis showed a direct correlation between total dose received and volume of rib irradiated with the probability of developing rib/chest wall pain at any point after follow-up. The median maximum dose at volumes {>=}0.008 cc of rib in patients who experienced chest wall pain was 132% of the prescribed dose versus 95% of the prescribed dose in those patients who did not experience pain (p = 0.0035). Conclusions: Although the incidence of chest wall/rib pain is quite low with APBI brachytherapy, attempts should be made to keep the volume of rib irradiated at a minimum and the maximum dose received by the chest wall as low as reasonably achievable.

  2. Doubling Graduation Rates: Three-Year Effects of CUNY's Accelerated Study in Associate Programs (ASAP) for Developmental Education Students

    ERIC Educational Resources Information Center

    Scrivener, Susan; Weiss, Michael J.; Ratledge, Alyssa; Rudd, Timothy; Sommo, Colleen; Fresques, Hannah

    2015-01-01

    Community colleges offer a pathway to the middle class for low-income individuals. Although access to college has expanded, graduation rates at community colleges remain low, especially for students who need developmental (remedial) courses to build their math, reading, or writing skills. The City University of New York's (CUNY's) Accelerated…

  3. Acceleration of atherogenesis in ApoE−/− mice exposed to acute or low-dose-rate ionizing radiation

    PubMed Central

    Mancuso, Mariateresa; Pasquali, Emanuela; Braga-Tanaka, Ignacia; Tanaka, Satoshi; Pannicelli, Alessandro; Giardullo, Paola; Pazzaglia, Simonetta; Tapio, Soile; Atkinson, Michael J.; Saran, Anna

    2015-01-01

    There is epidemiological evidence for increased non-cancer mortality, primarily due to circulatory diseases after radiation exposure above 0.5 Sv. We evaluated the effects of chronic low-dose rate versus acute exposures in a murine model of spontaneous atherogenesis. Female ApoE−/− mice (60 days) were chronically irradiated for 300 days with gamma rays at two different dose rates (1 mGy/day; 20 mGy/day), with total accumulated doses of 0.3 or 6 Gy. For comparison, age-matched ApoE−/− females were acutely exposed to the same doses and sacrificed 300 days post-irradiation. Mice acutely exposed to 0.3 or 6 Gy showed increased atherogenesis compared to age-matched controls, and this effect was persistent. When the same doses were delivered at low dose rate over 300 days, we again observed a significant impact on global development of atherosclerosis, although at 0.3 Gy effects were limited to the descending thoracic aorta. Our data suggest that a moderate dose of 0.3 Gy can have persistent detrimental effects on the cardiovascular system, and that a high dose of 6 Gy poses high risks at both high and low dose rates. Our results were clearly nonlinear with dose, suggesting that lower doses may be more damaging than predicted by a linear dose response. PMID:26359350

  4. Energy Calibration of the Scintillating Optical Fiber Calorimeter Chamber (SOFCAL)

    NASA Technical Reports Server (NTRS)

    Christl, M. C.; Fountain, W. F.; Parnell, T.; Roberts, F. E.; Gregory, J. C.; Johnson, J.; Takahashi, Y.

    1997-01-01

    The Scintillating Optical Fiber Calorimeter (SOFCAL) detector is designed to make direct measures of the primary cosmic ray spectrum from -200 GeV/amu - 20 TeV/amu. The primary particles are resolved into groups according to their charge (p, He, CNO, Medium Z, Heavy Z) using both active and passive components integrated into the detector. The principal part of SOFCAL is a thin ionization calorimeter that measures the electromagnetic cascades that result from these energetic particles interacting in the detector. The calorimeter is divided into two sections: a thin passive emulsion/x-ray film calorimeter, and a fiber calorimeter that uses crossing layers of small scintillating optical fibers to sample the energy deposition of the cascades. The energy determination is made by fitting the fiber data to transition curves generated by Monte Carlo simulations. The fiber data must first be calibrated using the electron counts from the emulsion plates in the calorimeter for a small number of events. The technique and results of this calibration will be presented together with samples of the data from a balloon flight.

  5. Accelerated Partial Breast Irradiation With Low-Dose-Rate Interstitial Implant Brachytherapy After Wide Local Excision: 12-Year Outcomes From a Prospective Trial

    SciTech Connect

    Hattangadi, Jona A.; Powell, Simon N.; MacDonald, Shannon M.; Mauceri, Thomas; Ancukiewicz, Marek; Freer, Phoebe; Lawenda, Brian; Alm El-Din, Mohamed A.; Gadd, Michele A.; Smith, Barbara L.; Taghian, Alphonse G.

    2012-07-01

    Purpose: To evaluate the long-term toxicity, cosmesis, and local control of accelerated partial breast irradiation with implant brachytherapy after wide local excision for Stage T1N0 breast cancer (BCa). Materials and Methods: Between 1997 and 2001, 50 patients with Stage T1N0M0 BCa were treated in a Phase I-II protocol using low-dose-rate accelerated partial breast irradiation with implant brachytherapy after wide local excision and lymph node surgery. The total dose was escalated in three groups: 50 Gy (n = 20), 55 Gy (n = 17), and 60 Gy (n = 13). Patient- and physician-assessed breast cosmesis, patient satisfaction, toxicity, mammographic abnormalities, repeat biopsies, and disease status were prospectively evaluated at each visit. Kendall's tau ({tau}{sub {beta}}) and logistic regression analyses were used to correlate outcomes with dose, implant volume, patient age, and systemic therapy. Results: The median follow-up period was 11.2 years (range, 4-14). The patient satisfaction rate was 67%, 67% reported good-excellent cosmesis, and 54% had moderate-severe fibrosis. Higher dose was correlated with worse cosmetic outcome ({tau}{sub {beta}} 0.6, p < .0001), lower patient satisfaction ({tau}{sub {beta}} 0.5, p < .001), and worse fibrosis ({tau}{sub {beta}} 0.4, p = .0024). Of the 50 patients, 35% had fat necrosis and 34% developed telangiectasias {>=}1 cm{sup 2}. Grade 3-4 late skin and subcutaneous toxicities were seen in 4 patients (9%) and 6 patients (13%), respectively, and both correlated with higher dose ({tau}{sub {beta}} 0.3-0.5, p {<=} .01). One patient had Grade 4 skin ulceration and fat necrosis requiring surgery. Mammographic abnormalities were seen in 32% of the patients, and 30% underwent repeat biopsy, of which 73% were benign. Six patients had ipsilateral breast recurrence: five elsewhere in the breast, and one at the implant site. One patient died of metastatic BCa after recurrence. The 12-year actuarial local control, recurrence-free survival

  6. Environmentally-relevant concentrations of atrazine induce non-monotonic acceleration of developmental rate and increased size at metamorphosis in Rhinella arenarum tadpoles.

    PubMed

    Brodeur, Julie C; Sassone, Alina; Hermida, Gladys N; Codugnello, Nadia

    2013-06-01

    Despite of the various studies reporting on the subject, anticipating the impacts of the widely-used herbicide atrazine on anuran tadpoles metamorphosis remains complex as increases or decreases of larval period duration are almost as frequently reported as an absence of effect. The aim of the present study was to examine the effects of environmentally-relevant concentrations of atrazine (0.1, 1, 10, 100, and 1000μg/L) on the timings of metamorphosis and body size at metamorphosis in the common South American toad, Rhinella arenarum (Anura: bufonidae). None of the atrazine concentrations tested significantly altered survival. Low atrazine concentrations in the range of 1-100μg/L were found to accelerate developmental rate in a non-monotonic U-shaped concentration-response relationship. This observed acceleration of the metamorphic process occurred entirely between stages 25 and 39; treated tadpoles proceeding through metamorphosis as control animals beyond this point. Together with proceeding through metamorphosis at a faster rate, tadpoles exposed to atrazine concentrations in the range of 1-100μg/L furthermore transformed into significantly larger metamorphs than controls, the concentration-response curve taking the form of an inverted U in this case. The no observed effect concentration (NOEC) was 0.1μg atrazine/L for both size at metamorphosis and timings of metamorphosis. Tadpoles exposed to 100μg/L 17β-estradiol presented the exact same alterations of developmental rate and body size as those treated with 1, 10 and 100μg/L of atrazine. Elements of the experimental design that facilitated the detection of alterations of metamorphosis at low concentrations of atrazine are discussed, together with the ecological significance of those findings.

  7. High Repetition Rate Electron Beam RF-Acceleration and Sub-Millimeter Wave Generation Via a Free Electron Laser.

    DTIC Science & Technology

    1986-02-14

    Period, Including Journal References: (a) D.B. McDermott, W.J. Nunan and N.C. Luhmann, Jr., "A High Duty Cycle, Compact 94 GHz Free Electron Laser...34 submitted to Journal IR and am-Waves. (b) W.J. Nunan , D.B. McDermott and N.C. Luhmann, Jr., "A High Repetition *Rate, Compact 94 GHz Free Electron Laser...34 Bulletin of the American Phy- * ) sical Society 30, 1543 (1985). L J (c) D.B. McDermott, W.J. Nunan and N.C. Luhmann, Jr., "A High RepetitionLL

  8. Biological Manipulation of Migration Rate: The Use of Advanced Photoperiod to Accelerate Smoltification in Yearling Chinook Salmon, Annual Report 1988.

    SciTech Connect

    Giorgi, Albert E.; Muir, William D.; Zaugg, Waldo S.

    1990-02-01

    Research was conducted to assess the feasibility of biologically manipulating physiological development and migratory behavior of yearling spring chinook salmon, Oncorhynchus tshawytscha. At Dworshak National Fish Hatchery a treatment group was exposed to a 3-month advanced photoperiod cycle for 14 weeks preceding release. Physiological development and migratory performance of this group was compared to a control group. Changes in physiological indices indicated that exposing fish to an advanced photoperiod treatment increased the rate of smolt development. Photoperiod treatment also altered passage patterns and timing at Lower Granite Dam. 26 refs., 6 figs., 7 tabs.

  9. Can Accelerators Accelerate Learning?

    NASA Astrophysics Data System (ADS)

    Santos, A. C. F.; Fonseca, P.; Coelho, L. F. S.

    2009-03-01

    The 'Young Talented' education program developed by the Brazilian State Funding Agency (FAPERJ) [1] makes it possible for high-schools students from public high schools to perform activities in scientific laboratories. In the Atomic and Molecular Physics Laboratory at Federal University of Rio de Janeiro (UFRJ), the students are confronted with modern research tools like the 1.7 MV ion accelerator. Being a user-friendly machine, the accelerator is easily manageable by the students, who can perform simple hands-on activities, stimulating interest in physics, and getting the students close to modern laboratory techniques.

  10. Accelerated rates of protein evolution in barley grain and pistil biased genes might be legacy of domestication.

    PubMed

    Shi, Tao; Dimitrov, Ivan; Zhang, Yinling; Tax, Frans E; Yi, Jing; Gou, Xiaoping; Li, Jia

    2015-10-01

    Traits related to grain and reproductive organs in grass crops have been under continuous directional selection during domestication. Barley is one of the oldest domesticated crops in human history. Thus genes associated with the grain and reproductive organs in barley may show evidence of dramatic evolutionary change. To understand how artificial selection contributes to protein evolution of biased genes in different barley organs, we used Digital Gene Expression analysis of six barley organs (grain, pistil, anther, leaf, stem and root) to identify genes with biased expression in specific organs. Pairwise comparisons of orthologs between barley and Brachypodium distachyon, as well as between highland and lowland barley cultivars mutually indicated that grain and pistil biased genes show relatively higher protein evolutionary rates compared with the median of all orthologs and other organ biased genes. Lineage-specific protein evolutionary rates estimation showed similar patterns with elevated protein evolution in barley grain and pistil biased genes, yet protein sequences generally evolve much faster in the lowland barley cultivar. Further functional annotations revealed that some of these grain and pistil biased genes with rapid protein evolution are related to nutrient biosynthesis and cell cycle/division. Our analyses provide insights into how domestication differentially shaped the evolution of genes specific to different organs of a crop species, and implications for future functional studies of domestication genes.

  11. High frequency alternating current chip nano calorimeter with laser heating

    SciTech Connect

    Shoifet, E.; Schick, C.; Chua, Y. Z.; Huth, H.

    2013-07-15

    Heat capacity spectroscopy at frequencies up to 100 kHz is commonly performed by thermal effusivity measurements applying the 3ω-technique. Here we show that AC-calorimetry using a thin film chip sensor allows for the measurement of frequency dependent heat capacity in the thin film limit up to about 1 MHz. Using films thinner than the thermal length of the thermal wave (∼1 μm) at such frequencies is advantageous because it provides heat capacity alone and not in combination with other quantities like thermal conductivity, at least on a qualitative basis. The used calorimetric sensor and the sample are each less than 1 μm thick. For high frequency AC-calorimetry, high cooling rates at very small temperature differences are required. This is realized by minimizing the heated spot to the size of the on chip thermocouple (3 × 6 μm{sup 2}). A modulated laser beam shaped and positioned by a glass fiber is used as the heat source. The device was used to measure the complex heat capacity in the vicinity of the dynamic glass transition (structural relaxation) of poly(methyl methacrylate). Combining different calorimeters finally provides data between 10{sup −3} Hz and 10{sup 6} Hz. In this frequency range the dynamic glass transition shifts about 120 K.

  12. High frequency alternating current chip nano calorimeter with laser heating.

    PubMed

    Shoifet, E; Chua, Y Z; Huth, H; Schick, C

    2013-07-01

    Heat capacity spectroscopy at frequencies up to 100 kHz is commonly performed by thermal effusivity measurements applying the 3ω-technique. Here we show that AC-calorimetry using a thin film chip sensor allows for the measurement of frequency dependent heat capacity in the thin film limit up to about 1 MHz. Using films thinner than the thermal length of the thermal wave (~1 μm) at such frequencies is advantageous because it provides heat capacity alone and not in combination with other quantities like thermal conductivity, at least on a qualitative basis. The used calorimetric sensor and the sample are each less than 1 μm thick. For high frequency AC-calorimetry, high cooling rates at very small temperature differences are required. This is realized by minimizing the heated spot to the size of the on chip thermocouple (3 × 6 μm(2)). A modulated laser beam shaped and positioned by a glass fiber is used as the heat source. The device was used to measure the complex heat capacity in the vicinity of the dynamic glass transition (structural relaxation) of poly(methyl methacrylate). Combining different calorimeters finally provides data between 10(-3) Hz and 10(6) Hz. In this frequency range the dynamic glass transition shifts about 120 K.

  13. High frequency alternating current chip nano calorimeter with laser heating

    NASA Astrophysics Data System (ADS)

    Shoifet, E.; Chua, Y. Z.; Huth, H.; Schick, C.

    2013-07-01

    Heat capacity spectroscopy at frequencies up to 100 kHz is commonly performed by thermal effusivity measurements applying the 3ω-technique. Here we show that AC-calorimetry using a thin film chip sensor allows for the measurement of frequency dependent heat capacity in the thin film limit up to about 1 MHz. Using films thinner than the thermal length of the thermal wave (˜1 μm) at such frequencies is advantageous because it provides heat capacity alone and not in combination with other quantities like thermal conductivity, at least on a qualitative basis. The used calorimetric sensor and the sample are each less than 1 μm thick. For high frequency AC-calorimetry, high cooling rates at very small temperature differences are required. This is realized by minimizing the heated spot to the size of the on chip thermocouple (3 × 6 μm2). A modulated laser beam shaped and positioned by a glass fiber is used as the heat source. The device was used to measure the complex heat capacity in the vicinity of the dynamic glass transition (structural relaxation) of poly(methyl methacrylate). Combining different calorimeters finally provides data between 10-3 Hz and 106 Hz. In this frequency range the dynamic glass transition shifts about 120 K.

  14. PARTICLE ACCELERATOR

    DOEpatents

    Teng, L.C.

    1960-01-19

    ABS>A combination of two accelerators, a cyclotron and a ring-shaped accelerator which has a portion disposed tangentially to the cyclotron, is described. Means are provided to transfer particles from the cyclotron to the ring accelerator including a magnetic deflector within the cyclotron, a magnetic shield between the ring accelerator and the cyclotron, and a magnetic inflector within the ring accelerator.

  15. Accelerating Rates of Discontinuous Permafrost Thaw Associated with Ground Surface Morphology and Changing Vegetation Structures Determined from Multi-Temporal LIDAR Data

    NASA Astrophysics Data System (ADS)

    Chasmer, L.; Hopkinson, C.

    2015-12-01

    Rates of permafrost thaw within the discontinuous permafrost zone are expected to accelerate with permafrost fragmentation. However quantification of drivers of permafrost change remain elusive due to the non-linearity of feedbacks in space and time. Given the extent of permafrost in Canada, there is significant interest in the mechanisms associated with land cover change as climate change and disturbance intensifies.We quantify the variability of rates of thaw associated with structural characteristics of the land surface within a discontinuous permafrost watershed in the NWT, Canada. Results are compared to an isolated permafrost watershed in Alberta, which may exemplify the northern discontinuous landscape in ~350 years. Three airborne Light Detection And Ranging (LiDAR) datasets have been collected in 2008, 2011 and 2015, coincident with digital photogrammetry (2008), thermal infrared (2011) and bathymetry (2015) within both watersheds. Rates of change of land elevation associated with permafrost thaw within plateaus and peatlands are quantified using non-linear spatial regression, and compared with topographic and vegetation derivatives. Results indicate that increasing fragmentation of discontinuous permafrost plateaus results in exponential thaw. Rates of thaw become linear with decreasing complexity. Accelerating thaw is related to substantial Picea mariana mortality (up to 45%), increased gap fraction within 1-2 m of plateau edges, and shrub succession (average growth ~0.2 m yr—1) at the 0-2m boundary within the 7-year period. Thaw rate in parts is also complicated by understory succession within the area of local convexity between the plateau and slope edge and linear thaw pathways. Greatest rates of thaw and vegetation mortality (~30-50%) are found on plateaus with populous tremuloides. In the central boreal watershed, vegetation succession at peatland margins is associated with increased drying and changes to runoff trends over the last 40 years

  16. Examination of Ion Beam Acceleration in A High Power-Low Pressure and Gas Flow Rates Argon Plasma Created in the MadHeX Helicon Source

    NASA Astrophysics Data System (ADS)

    Sung, Yung-Ta; Devinney, Michael; Scharer, John

    2012-10-01

    The modified MadHeX experimental system consists of a Pyrex tube connected to a stainless steel chamber with an axial magnetic nozzle field, variable up to 1 kG at the source region that has been upgraded to minimize neutral reflux and reduce neutral concentrations in the chamber. A half-turn double-helix antenna is used to excite helicon waves in the source. An ion beam of energy, E = 160 eV at 500 W RF power, has been observed in a low flowing argon plasma formed in the expanding region with a 340 G magnetic field. The role of plasma positive ``self-bias'' and the effects of boundary conditions are discussed. The measured density decrease factor of 18 at 100 W RF power across the expansion region yields a higher ion acceleration and agrees with a conservation-of-flux calculation. The effect of lower flow rates and pressures, higher RF powers and magnetic field strength dependence on the ion beam acceleration, plasma potential, electron density and temperature are further explored. The axial ion velocity distribution function and temperatures at higher powers are observed by argon 668 nm laser induced fluorescence with density measurements by interferometry. The electron energy distribution and its possible non-Maxwellian tail are examined using optical emission spectroscopy (ADAS and Vlcek models).

  17. Accelerated Stem Growth Rates and Improved Fiber Properties of Loblolly Pine: Functional Analysis Of CyclinD from Pinus taeda

    SciTech Connect

    Dr. John Cairney, School of Biology and Institute of Paper Science and Technology @ Georgia Tech, Georgia Institute of Technology; Dr. Gary Peter, University of Florida; Dr. Ulrika Egertsdotter, Dept. of Forestry, Virgina Tech; Dr. Armin Wagner, New Zealand Forest Research Institute Ltd.

    2005-11-30

    A sustained supply of low-cost, high quality raw materials is essential for the future success of the U.S. forest products industry. To maximize stem (trunk) growth, a fundamental understanding of the molecular mechanisms that regulate cell divisions within the cambial meristem is essential. We hypothesize that auxin levels within the cambial meristem regulate cyclin gene expression and this in turn controls cell cycle progression as occurs in all eukaryotic cells. Work with model plant species has shown that ectopic overexpression of cyclins promotes cell division thereby increasing root growth > five times. We intended to test whether ectopic overexpression of cambial cyclins in the cambial zone of loblolly pine also promotes cell division rates that enhance stem growth rates. Results generated in model annual angiosperm systems cannot be reliably extrapolated to perennial gymnosperms, thus while the generation and development of transgenic pine is time consuming, this is the necessary approach for meaningful data. We succeeded in isolating a cyclin D gene and Clustal analysis to the Arabidopsis cyclin D gene family indicates that it is more closely related to cyclin D2 than D1 or D3 Using this gene as a probe we observed a small stimulation of cyclin D expression in somatic embryo culture upon addition of auxin. We hypothesized that trees with more cells in the vascular cambial and expansion zones will have higher cyclin mRNA levels. We demonstrated that in trees under compressive stress where the rates of cambial divisions are increased on the underside of the stem relative to the top or opposite side, there was a 20 fold increase in the level of PtcyclinD1 mRNA on the compressed side of the stem relative to the opposite. This suggests that higher secondary growth rates correlate with PtcyclinD1 expression. We showed that larger diameter trees show more growth during each year and that the increased growth in loblolly pine trees correlates with more cell

  18. Catalytic Friedel-Crafts C-H Borylation of Electron-Rich Arenes: Dramatic Rate Acceleration by Added Alkenes.

    PubMed

    Yin, Qin; Klare, Hendrik F T; Oestreich, Martin

    2017-03-20

    In the electrophilic C-H borylation of electron-rich aromatic compounds with catecholborane, the catalytic generation of the boron electrophile is initiated by heterolysis of the B-H bond by various Lewis and Brønsted acids, with a boronium ion formed exclusively. After ligand dissociation, the corresponding borenium ion undergoes regioselective electrophilic aromatic substitution on aniline derivatives as well as nitrogen-containing heterocycles. The catalysis is optimized using B(C6 F5 )3 as the initiator and proceeds without the addition of an external base or dihydrogen acceptor. Temperatures above 80 °C are generally required to secure efficient turnover in these Friedel-Crafts-type reactions. Mechanistic experiments reveal that regeneration of the boronium/borenium ion with dihydrogen release is rate-determining. This finding finally led to the discovery that, with added alkenes, catalytic C-H borylations can, for the first time, be carried out at room temperature.

  19. High Resolution, Non-Dispersive X-Ray Calorimeter Spectrometers on EBITs and Orbiting Observatories

    NASA Technical Reports Server (NTRS)

    Porter, Frederick S.

    2010-01-01

    X-ray spectroscopy is the primary tool for performing atomic physics with Electron beam ion trap (EBITs). X-ray instruments have generally fallen into two general categories, 1) dispersive instruments with very high spectral resolving powers but limited spectral range, limited count rates, and require an entrance slit, generally, for EBITs, defined by the electron beam itself, and 2) non-dispersive solid-state detectors with much lower spectral resolving powers but that have a broad dynamic range, high count rate ability and do not require a slit. Both of these approaches have compromises that limit the type and efficiency of measurements that can be performed. In 1984 NASA initiated a program to produce a non-dispersive instrument with high spectral resolving power for x-ray astrophysics based on the cryogenic x-ray calorimeter. This program produced the XRS non-dispersive spectrometers on the Astro-E, Astro-E2 (Suzaku) orbiting observatories, the SXS instrument on the Astro-H observatory, and the planned XMS instrument on the International X-ray Observatory. Complimenting these spaceflight programs, a permanent high-resolution x-ray calorimeter spectrometer, the XRS/EBIT, was installed on the LLNL EBIT in 2000. This unique instrument was upgraded to a spectral resolving power of 1000 at 6 keV in 2003 and replaced by a nearly autonomous production-class spectrometer, the EBIT Calorimeter Spectrometer (ECS), in 2007. The ECS spectrometer has a simultaneous bandpass from 0.07 to over 100 keV with a spectral resolving power of 1300 at 6 keV with unit quantum efficiency, and 1900 at 60 keV with a quantum efficiency of 30%. X-ray calorimeters are event based, single photon spectrometers with event time tagging to better than 10 us. We are currently developing a follow-on instrument based on a newer generation of x-ray calorimeters with a spectral resolving power of 3000 at 6 keV, and improved timing and measurement cadence. The unique capabilities of the x

  20. Internal short circuit and accelerated rate calorimetry tests of lithium-ion cells: Considerations for methane-air intrinsic safety and explosion proof/flameproof protection methods

    PubMed Central

    Dubaniewicz, Thomas H.; DuCarme, Joseph P.

    2016-01-01

    Researchers with the National Institute for Occupational Safety and Health (NIOSH) studied the potential for lithium-ion cell thermal runaway from an internal short circuit in equipment for use in underground coal mines. In this third phase of the study, researchers compared plastic wedge crush-induced internal short circuit tests of selected lithium-ion cells within methane (CH4)-air mixtures with accelerated rate calorimetry tests of similar cells. Plastic wedge crush test results with metal oxide lithium-ion cells extracted from intrinsically safe evaluated equipment were mixed, with one cell model igniting the chamber atmosphere while another cell model did not. The two cells models exhibited different internal short circuit behaviors. A lithium iron phosphate (LiFePO4) cell model was tolerant to crush-induced internal short circuits within CH4-air, tested under manufacturer recommended charging conditions. Accelerating rate calorimetry tests with similar cells within a nitrogen purged 353-mL chamber produced ignitions that exceeded explosion proof and flameproof enclosure minimum internal pressure design criteria. Ignition pressures within a 20-L chamber with 6.5% CH4-air were relatively low, with much larger head space volume and less adiabatic test conditions. The literature indicates that sizeable lithium thionyl chloride (LiSOCl2) primary (non rechargeable) cell ignitions can be especially violent and toxic. Because ignition of an explosive atmosphere is expected within explosion proof or flameproof enclosures, there is a need to consider the potential for an internal explosive atmosphere ignition in combination with a lithium or lithium-ion battery thermal runaway process, and the resulting effects on the enclosure. PMID:27695201

  1. Internal short circuit and accelerated rate calorimetry tests of lithium-ion cells: Considerations for methane-air intrinsic safety and explosion proof/flameproof protection methods.

    PubMed

    Dubaniewicz, Thomas H; DuCarme, Joseph P

    2016-09-01

    Researchers with the National Institute for Occupational Safety and Health (NIOSH) studied the potential for lithium-ion cell thermal runaway from an internal short circuit in equipment for use in underground coal mines. In this third phase of the study, researchers compared plastic wedge crush-induced internal short circuit tests of selected lithium-ion cells within methane (CH4)-air mixtures with accelerated rate calorimetry tests of similar cells. Plastic wedge crush test results with metal oxide lithium-ion cells extracted from intrinsically safe evaluated equipment were mixed, with one cell model igniting the chamber atmosphere while another cell model did not. The two cells models exhibited different internal short circuit behaviors. A lithium iron phosphate (LiFePO4) cell model was tolerant to crush-induced internal short circuits within CH4-air, tested under manufacturer recommended charging conditions. Accelerating rate calorimetry tests with similar cells within a nitrogen purged 353-mL chamber produced ignitions that exceeded explosion proof and flameproof enclosure minimum internal pressure design criteria. Ignition pressures within a 20-L chamber with 6.5% CH4-air were relatively low, with much larger head space volume and less adiabatic test conditions. The literature indicates that sizeable lithium thionyl chloride (LiSOCl2) primary (non rechargeable) cell ignitions can be especially violent and toxic. Because ignition of an explosive atmosphere is expected within explosion proof or flameproof enclosures, there is a need to consider the potential for an internal explosive atmosphere ignition in combination with a lithium or lithium-ion battery thermal runaway process, and the resulting effects on the enclosure.

  2. Rate acceleration of the heterogeneous reaction of ozone with a model alkene at the air-ice interface at low temperatures.

    PubMed

    Ray, Debajyoti; Malongwe, Joseph K'Ekuboni; Klán, Petr

    2013-07-02

    The kinetics of the ozonation reaction of 1,1-diphenylethylene (DPE) on the surface of ice grains (also called "artificial snow"), produced by shock-freezing of DPE aqueous solutions or DPE vapor-deposition on pure ice grains, was studied in the temperature range of 268 to 188 K. A remarkable and unexpected increase in the apparent ozonation rates with decreasing temperature was evaluated using the Langmuir-Hinshelwood and Eley-Rideal kinetic models, and by estimating the apparent specific surface area of the ice grains. We suggest that an increase of the number of surface reactive sites, and possibly higher ozone uptake coefficients are responsible for the apparent rate acceleration of DPE ozonation at the air-ice interface at lower temperatures. The increasing number of reactive sites is probably related to the fact that organic molecules are displaced more to the top of a disordered interface (or quasi-liquid) layer on the ice surface, which makes them more accessible to the gas-phase reactants. The effect of NaCl as a cocontaminant on ozonation rates was also investigated. The environmental implications of this phenomenon for natural ice/snow are discussed. DPE was selected as an example of environmentally relevant species which can react with ozone. For typical atmospheric ozone concentrations in polar areas (20 ppbv), we estimated that its half-life on the ice surface would decrease from ∼5 days at 258 K to ∼13 h at 188 K at submonolayer DPE loadings.

  3. Design and status of the Mu2e electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Atanov, N.; Baranov, V.; Budagov, J.; Carosi, R.; Cervelli, F.; Colao, F.; Cordelli, M.; Corradi, G.; Dané, E.; Davydov, Yu. I.; Di Falco, S.; Donati, S.; Donghia, R.; Echenard, B.; Flood, K.; Giovannella, S.; Glagolev, V.; Grancagnolo, F.; Happacher, F.; Hitlin, D. G.; Martini, M.; Miscetti, S.; Miyashita, T.; Morescalchi, L.; Murat, P.; Pasciuto, D.; Pezzullo, G.; Porter, F.; Saputi, A.; Sarra, I.; Soleti, S. R.; Spinella, F.; Tassielli, G.; Tereshchenko, V.; Usubov, Z.; Zhu, R. Y.

    2016-07-01

    The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5 ×10-17 after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.

  4. Research on calorimeter for high-power microwave measurements

    SciTech Connect

    Ye, Hu; Ning, Hui; Yang, Wensen; Tian, Yanmin; Xiong, Zhengfeng; Yang, Meng; Yan, Feng; Cui, Xinhong

    2015-12-15

    Based on measurement of the volume increment of polar liquid that is a result of heating by absorbed microwave energy, two types of calorimeters with coaxial capacitive probes for measurement of high-power microwave energy are designed in this paper. The first is an “inline” calorimeter, which is placed as an absorbing load at the end of the output waveguide, and the second is an “offline” calorimeter that is placed 20 cm away from the radiation horn of the high-power microwave generator. Ethanol and high density polyethylene are used as the absorbing and housing materials, respectively. Results from both simulations and a “cold test” on a 9.3 GHz klystron show that the “inline” calorimeter has a measurement range of more than 100 J and an energy absorption coefficient of 93%, while the experimental results on a 9.3 GHz relativistic backward-wave oscillator show that the device’s power capacity is approximately 0.9 GW. The same experiments were also carried out for the “offline” calorimeter, and the results indicate that it can be used to eliminate the effects of the shock of the solenoid on the measurement curves and that the device has a higher power capacity of 2.5 GW. The results of the numerical simulations, the “cold tests,” and the experiments show good agreement.

  5. Design and status of the Mu2e electromagnetic calorimeter

    SciTech Connect

    Atanov, N.; Baranov, V.; Budagov, J.; Carosi, R.; Cervelli, F.; Colao, F.; Cordelli, M.; Corradi, G.; Dane, E.; Davydov, Yu. I.; Di Falco, S.; Donati, S.; Donghia, R.; Echenard, B.; Flood, K.; Giovannella, S.; Glagolev, V.; Grancagnolo, F.; Happacher, F.; Hitlin, D. G.; Martini, M.; Miscetti, Stefano; Miyashita, T.; Morescalchi, L.; Murat, P.; Pasciuto, D.; Pezzullo, G.; Porter, F.; Saputi, A.; Sarra, I.; Soleti, S. R.; Spinella, F.; Tassielli, G.; Tereshchenko, V.; Usubov, Z.; Zhu, R. Y.

    2015-10-02

    Here, the Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5×10–17 after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D; studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.

  6. Design and status of the Mu2e electromagnetic calorimeter

    DOE PAGES

    Atanov, N.; Baranov, V.; Budagov, J.; ...

    2015-10-02

    Here, the Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5×10–17 after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to matchmore » these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D; studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.« less

  7. Research on calorimeter for high-power microwave measurements

    NASA Astrophysics Data System (ADS)

    Ye, Hu; Ning, Hui; Yang, Wensen; Tian, Yanmin; Xiong, Zhengfeng; Yang, Meng; Yan, Feng; Cui, Xinhong

    2015-12-01

    Based on measurement of the volume increment of polar liquid that is a result of heating by absorbed microwave energy, two types of calorimeters with coaxial capacitive probes for measurement of high-power microwave energy are designed in this paper. The first is an "inline" calorimeter, which is placed as an absorbing load at the end of the output waveguide, and the second is an "offline" calorimeter that is placed 20 cm away from the radiation horn of the high-power microwave generator. Ethanol and high density polyethylene are used as the absorbing and housing materials, respectively. Results from both simulations and a "cold test" on a 9.3 GHz klystron show that the "inline" calorimeter has a measurement range of more than 100 J and an energy absorption coefficient of 93%, while the experimental results on a 9.3 GHz relativistic backward-wave oscillator show that the device's power capacity is approximately 0.9 GW. The same experiments were also carried out for the "offline" calorimeter, and the results indicate that it can be used to eliminate the effects of the shock of the solenoid on the measurement curves and that the device has a higher power capacity of 2.5 GW. The results of the numerical simulations, the "cold tests," and the experiments show good agreement.

  8. Characterization of Novel Calorimeters in the Annular Core Research Reactor

    NASA Astrophysics Data System (ADS)

    Hehr, Brian D.; Parma, Edward J.; Peters, Curtis D.; Naranjo, Gerald E.; Luker, S. Michael

    2016-02-01

    A series of pulsed irradiation experiments have been performed in the central cavity of Sandia National Laboratories' Annular Core Research Reactor (ACRR) to characterize the responses of a set of elemental calorimeter materials including Si, Zr, Sn, Ta, W, and Bi. Of particular interest was the perturbing effect of the calorimeter itself on the ambient radiation field - a potential concern in dosimetry applications. By placing the calorimeter package into a neutron-thermalizing lead/polyethylene (LP) bucket and irradiating both with and without a cadmium wrapper, it was demonstrated that prompt capture gammas generated inside the calorimeters can be a significant contributor to the measured dose in the active disc region. An MCNP model of the experimental setup was shown to replicate measured dose responses to within 10%. The internal (n,γ) contribution was found to constitute as much as 50% of the response inside the LP bucket and up to 20% inside the nominal (unmodified) cavity environment, with Ta and W exhibiting the largest enhancement due to their sizable (n,γ) cross sections. Capture reactions in non-disc components of the calorimeter were estimated to be responsible for up to a few percent of the measured response. This work was supported by the United States Department of Energy under Contract DE-AC04-94AL85000. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy.

  9. D-0 North End Cap Calorimeter Cold Test Results

    SciTech Connect

    Michael, J.; /Fermilab

    1990-08-02

    The North endcap calorimeter vessel was recieved on July 1, 1990. A cooldown of the pressure vessel with liquid nitrogen was performed on July 10-11 to check the vessel's integrity. With the pressure vessel cold, the insulating vacuum was monitored for leaks. Through out the testing, the insulating vacuum remained good and the vessel passed the test. The cold test was carried out per the procedures of D-Zero engineering note 3740.220-EN-250. The test was very similar to the cold test performed on the Central Calorimeter in October of 1987. Reference D-Zero engineering notes 3740.210-EN-122, 3740.000-EN107, and 3740.210-EN-110 for information about the CC cold test. The insulating vacuum space was pumped on while equipment was being connected to the pressure vessel. Two hours after starting to pump with the blower the vacuum space pressure was at about 210 microns. Pumping on the vacuum space for the next 15 hours showed no progress and a leak detector was connected to the pumping line. A leak check showed a leak in a thermocouple feedthru on the vacuum space relief plate. After fixing the leak, the pressure dropped to 16 microns in less than one hour. A rate of rise test was performed starting at a pressure of 13 microns. The pressure rose to 39 microns within 8 minutes and then only rose to 43 microns in 2.5 hours (1.6 microns/hour). After all connections were made to the pressure vessel, a vacuum pump with an estimated effective pumping speed of about 70 scfm was valved on. The lowest pressure achieved after 2 days of pumping was 80 microns. Valving out the pump for 30 minutes resulted in a 5 micron per minute rate of rise. The rate of rise was considered acceptable since there were known leak paths through the bolts of the signal ports. The EC North vessel was rolled outside of Lab A in preparation for a 5000 gallon liquid nitrogen trailer which arrived July, 10 at 8:00am. Before filling the vessel, the vacuum space pump was valved off. The pressure in the

  10. ATLAS level-1 calorimeter trigger: Run-2 performance and Phase-1 upgrades

    NASA Astrophysics Data System (ADS)

    Carlson, Ben; Hong, Tae Min; Atlas Collaboration

    2017-01-01

    The Run-2 performance and Phase-1 upgrade are presented for the hardware-based level-1 calorimeter trigger (L1Calo) for the ATLAS Experiment. This trigger has a latency of about 2.2 microseconds to make a decision to help ATLAS select about 100 kHz of the most interesting collisions from the nominal LHC rate of 40 MHz. We summarize the upgrade after Run-1 (2009-2012) and discuss its performance in Run-2 (2015-current). We also outline the on-going Phase-1 upgrade for the next run (2021-2024) and its expected performance.

  11. A compact light readout system for longitudinally segmented shashlik calorimeters

    NASA Astrophysics Data System (ADS)

    Berra, A.; Brizzolari, C.; Cecchini, S.; Cindolo, F.; Jollet, C.; Longhin, A.; Ludovici, L.; Mandrioli, G.; Mauri, N.; Meregaglia, A.; Paoloni, A.; Pasqualini, L.; Patrizii, L.; Pozzato, M.; Pupilli, F.; Prest, M.; Sirri, G.; Terranova, F.; Vallazza, E.; Votano, L.

    2016-09-01

    The longitudinal segmentation of shashlik calorimeters is challenged by dead zones and non-uniformities introduced by the light collection and readout system. This limitation can be overcome by direct fiber-photosensor coupling, avoiding routing and bundling of the wavelength shifter fibers and embedding ultra-compact photosensors (SiPMs) in the bulk of the calorimeter. We present the first experimental test of this readout scheme performed at the CERN PS-T9 beamline in 2015 with negative particles in the 1-5 GeV energy range. In this paper, we demonstrate that the scheme does not compromise the energy resolution and linearity compared with standard light collection and readout systems. In addition, we study the performance of the calorimeter for partially contained charged hadrons to assess the e / π separation capability and the response of the photosensors to direct ionization.

  12. Highly granular hadron calorimeter: software compensation and shower decomposition

    NASA Astrophysics Data System (ADS)

    Chadeeva, M.; CALICE Collaboration

    2016-02-01

    The highly granular analogue hadron calorimeter was developed and constructed by the CALICE collaboration. The active layers of the calorimeter are assembled from scintillator tiles with individual readout by silicon photomultipliers and are interleaved with absorber plates. The response and resolution of the calorimeter equipped with steel absorber was intensively tested in single particle beams. The application of software compensation techniques developed for the scintillator-steel prototype allows for reduction of the stochastic term of the single particle resolution from 58%/ √E/GeV to 45%/ √E/GeV. The detailed study and decomposition of the longitudinal and radial profiles of hadron-induced showers in the energy range from 10 to 80 GeV are presented and compared to GEANT4 simulations.

  13. Calibration and monitoring systems of the ATLAS tile hadron calorimeter

    NASA Astrophysics Data System (ADS)

    Boumediene, D.

    2013-08-01

    The TileCal is the hadronic calorimeter covering the most central region of the ATLAS experiment at LHC. It is a sampling calorimeter with iron plates as absorber and plastic scintillating tiles as the active material. The scintillation light produced by the passage of charged particles is transmitted by wavelength shifting fibers to about 10,000 photomultiplier tubes (PMTs). Integrated to the calorimeter, there is a composite device that allows to monitor and/or equalize the signals at various stages of their formation. This device is based on signal generation from different sources: radioactive, LASER, charge injection and minimum bias events produced in proton-proton collisions. Recent performances of these systems are presented.

  14. CMS Hadron Endcap Calorimeter Upgrade Studies for Super-LHC

    NASA Astrophysics Data System (ADS)

    Bilki, Burak; CMS HCAL Collaboration

    2011-04-01

    When the Large Hadron Collider approaches Super-LHC conditions above a luminosity of 1034cm-2s-1, the scintillator tiles of the CMS Hadron Endcap calorimeters will lose their efficiencies. As a radiation hard solution, the scintillator tiles are planned to be replaced by quartz plates. In order to improve the efficiency of the photodetection, various methods were investigated including radiation hard wavelength shifters, p-terphenyl or 4% gallium doped zinc oxide. We constructed a 20 layer calorimeter prototype with pTp coated plates of size 20 cm × 20 cm, and tested the hadronic and the electromagnetic capabilities at the CERN H2 beam-line. The beam tests revealed a substantial light collection increase with pTp or ZnO:Ga deposited quartz plates. Here we report on the current R&D for a viable endcap calorimeter solution for CMS with beam tests and radiation damage studies.

  15. Performance of the DELPHI small angle tile calorimeter

    SciTech Connect

    Alvsvaag, S.J.; Maeland, O.A.; Klovning, A.

    1996-06-01

    The DELPHI STIC detector is a lead-scintillator sampling calorimeter with wave length shifting optical fibers used for light collection. The main goal of the calorimeter at LEP100 is to measure the luminosity with an accuracy better than 0.1%. The detector has been in operation since the 1994 LEP run. Presented here is the performance measured during the 1994--1995 LEP runs, with the emphasis on the achieved energy and space resolution, the long-term stability and the efficiency of the detector. The new bunchtrains mode of LEP requires a rather sophisticated trigger and timing scheme which is also presented. To control the trigger efficiency and stability of the calorimeter channels, a LED-based monitoring system has been developed.

  16. In-flight second order correction of PAMELA calorimeter characteristics (for simulation in Geant4)

    NASA Astrophysics Data System (ADS)

    Dunaeva, O. A.; Alekseev, V. V.; Bogomolov, Yu V.; Lukyanov, A. D.; Malakhov, V. V.; Mayorov, A. G.; Rodenko, S. A.

    2017-01-01

    Simulation of the PAMELA spectrometer characteristics is performed with the special program accepted by the PAMELA collaboration based on Geant4 package, which needs a detailed information about geometry, materials etc. of scientific equipment. This data is taken from manufactures or obtained from different ground-based tests including accelerators. We propose a method of in-flight verification of calorimeter characteristics. To calculate them we select relativistic protons passing through all the spectrometer without interactions. We obtain correction values from a comparison of experimental data and simulation in assumption that electromagnetic processes are performed in Geant4 with high precision. As a result, characteristics of silicon detectors (the sensitive part) are verified. Correction factor is 2.0 ± 0.3% with respect to original value.

  17. A pure CsI calorimeter for the Belle II experiment at SuperKEKB

    NASA Astrophysics Data System (ADS)

    Aloisio, A.; Baccaro, S.; Bernieri, E.; Branchini, P.; Budano, A.; Budano, F.; Cecchi, C.; Cemmi, A.; Corradi, G.; De Lucia, E.; De Nardo, G.; de Sangro, R.; Finocchiaro, G.; Fiore, S.; Giordano, R.; Manoni, E.; Merola, M.; Montecchi, M.; Oberhof, B.; Passeri, A.; Peruzzi, I.; Piccolo, M.; Rossi, A.; Sciacca, C.; Tagnani, D.

    2016-07-01

    The new SuperKEKB collider will be an upgrade of the existing KEKB electron-positron asymmetric collider, with a target luminosity of 8 ×1035cm-2s-1, about 40 times greater than the previous one. The accelerator upgrade is based on the novel low-emittance "nanobeams" scheme. The detector will also be upgraded to cope with the higher luminosity, pile-up and occupancy. We report on the development of the new pure CsI calorimeter for the forward region. An intensive R&D has been carried out to study the performance of pure CsI crystals with Avalanche Photodiodes readout. Results on the signal to noise ratio for different sensors and front end electronics configurations will be presented. A matrix of 16 crystals has been tested with the electron beam at the BTF facility in Frascati. Results in terms of energy resolution of this prototype will also be discussed.

  18. Improvements in a calorimeter for high-power CW lasers

    NASA Technical Reports Server (NTRS)

    Chamberlain, G. E.; Simpson, P. A.; Smith, R. L.

    1978-01-01

    A technique for improving the measurement certainty with the BB series (Smith et al., 1972) of electrically calibrated calorimeters used in high-energy lasers is described. The technique is based on monitoring the energy which is backscattered from the meter and monitoring the overspill radiation impinging on the calorimeter at the entrance aperture. The design and performance of a second generation BB meter is discussed and compared to that of the original device in terms of number of electrical calibrations, the residual standard deviation of electrical calibration, the calibration constant for laser energy, the correcting factor for systematics, inaccuracy, imprecision, and uncertainty.

  19. The Scintillating Optical Fiber Calorimeter Instrument Performance (SOFCAL)

    NASA Technical Reports Server (NTRS)

    Christl, M. J.; Benson, C. M.; Berry, F. A.; Fountain, W. F.; Gregory, J. C.; Johnson, J. S.; Munroe, R. B.; Parnell, T. A.; Takahashi, Y.; Watts, J. W.

    1999-01-01

    SOFCAL is a balloon-borne instrument designed to measure the P-He cosmic ray spectra from about 200 GeV/amu - 20 TeV/amu. SOFCAL uses a thin lead and scintillating-fiber ionization calorimeter to measure the cascades produced by cosmic rays interacting in the hybrid detector system. Above the fiber calorimeter is an emulsion chamber that provides the interaction target, primary particle identification and in-flight energy calibration for the scintillating fiber data. The energy measurement technique and its calibration are described, and the present results from the analysis of a 1 day balloon flight will be presented.

  20. Design and Prototyping of a High Granularity Scintillator Calorimeter

    SciTech Connect

    Zutshi, Vishnu

    2016-03-27

    A novel approach for constructing fine-granularity scintillator calorimeters, based on the concept of an Integrated Readout Layer (IRL) was developed. The IRL consists of a printed circuit board inside the detector which supports the directly-coupled scintillator tiles, connects to the surface-mount SiPMs and carries the necessary front-end electronics and signal/bias traces. Prototype IRLs using this concept were designed, prototyped and successfully exposed to test beams. Concepts and implementations of an IRL carried out with funds associated with this contract promise to result in the next generation of scintillator calorimeters.

  1. Phase 1 upgrade of the CMS forward hadronic calorimeter

    NASA Astrophysics Data System (ADS)

    Noonan, D.

    2017-02-01

    The CMS experiment at the Large Hadron Collider at CERN is upgrading the photo-detection and readout system of the forward hadronic calorimeter. The phase 1 upgrade of the CMS forward calorimeter requires the replacement of the current photomultiplier tubes, as well as the installation of a new front-end readout system. The new photomultiplier tubes contain a thinner window as well as multi-anode readout. The front-end electronics will use the QIE10 ASIC which combines signal digitization with timing information. The major components of the upgrade as well as the current status are described in this paper.

  2. Field test of the bulk-assay calorimeter

    SciTech Connect

    Perry, R.B.; Keddar, A.

    1982-10-01

    The Bulk-Assay Calorimeter described in ANL-NDA-9/ISPO-14 was field tested at the Belgonucleaire mixed-oxide fuel fabrication plant at Dessel, Belgium, May 13-19, 1982. This instrument was developed under ISPO Tasks A-9 and A-47 at Argonne National Laboratory and was supplied to the IAEA through the U.S support program. Five containers of plutonium-oxide feed stock used in the manufacture of mixed-oxide LMFBR-type fuel were assayed during the test. Electrical measurements to verify the calibration of the calorimeter were also made.

  3. Radiation damage studies for the SDC electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Fazely, A. R.; Gunasingha, R.; Imlay, R. L.; Khosravi, E. S.; Lim, Jit-Ning; Lyndon, C.; McMills, G.; McNeil, R. R.; Metcalf, W. J.; Courtney, J. C.; Tashakkori, R.; Vegara, B. J.

    1993-01-01

    We report the results from a year long study aimed at radiation resistance and optical performance of scintillator tile with green wave shifter fiber readout. A careful investigation of several rad-hard plastic scintillators from Bicron and Kuraray, studies indicate that for a specific rad-hard Bicron scintillator, it is possible to build a tile/fiber EM calorimeter that can operate in the design luminosity of SSC. This calorimeter with excellent optical response would only have a light loss of about 5% after being exposed to 1 Mrad.

  4. The upgrade of the ATLAS first-level calorimeter trigger

    NASA Astrophysics Data System (ADS)

    Yamamoto, Shimpei

    2016-07-01

    The first-level calorimeter trigger (L1Calo) had operated successfully through the first data taking phase of the ATLAS experiment at the CERN Large Hadron Collider. Towards forthcoming LHC runs, a series of upgrades is planned for L1Calo to face new challenges posed by the upcoming increases of the beam energy and the luminosity. This paper reviews the ATLAS L1Calo trigger upgrade project that introduces new architectures for the liquid-argon calorimeter trigger readout and the L1Calo trigger processing system.

  5. A purity monitor for the KEDR liquid krypton calorimeter

    SciTech Connect

    Evtushenko, P. N.; Kotov, K. Yu.; Maslennikov, A. L.; Peleganchuk, S. V.; Snopkov, R. G.; Rogozin, A. I.; Tikhonov, Yu. A.

    2016-06-01

    We present a purity monitor for the KEDR liquid krypton calorimeter. A new method is suggested based on the usage of a short pulse of a gas discharge as a source of ultraviolet radiation for the photoproduction of electrons in a drift cell of the monitor. This paper describes the design of the monitor, the results of experiments with gaseous and liquid krypton, as well as the experience of using the developed device in the process of krypton purification for the KEDR liquid krypton calorimeter.

  6. Poster — Thur Eve — 22: A water calorimeter for low-energy particle beams

    SciTech Connect

    Renaud, J; Sarfehnia, A; Seuntjens, J; Rossomme, S; Vynckier, S

    2014-08-15

    In this work, the feasibility of absolute dose to water measurements in low-energy electron beams using a water calorimeter specifically developed for shallow measurements is established. The calorimeter design consists of a cylindrical glass vessel encased in a block of expanded polystyrene. The vessel has a front window thickness of 1.1 mm, a 4 cm radius, and is 2.5 cm in depth. The vessel-block assembly sits inside a thermally-insulated box and is air-cooled to an operating temperature of 4 °C. Radiation-induced thermal gradients were simulated in a geometric model of the calorimeter using a finite element analysis software package. 52 absorbed dose to water measurements were performed in a 6 and 8 MeV electron beam (z{sub max} of 1.32 and 1.76 cm, respectively) for 60 seconds at a repetition rate of 400 MU/min and an SSD of 120 cm. Within the vessel, the depth of measurement was set to 1.08 cm relative to the inner front window. The average measured dose to water was 59.6 ± 0.2 cGy/100 MU (6 MeV), and 63.7 ± 0.3 cGy/100 MU (8 MeV). The associated heat transfer corrections were determined to be 1.026 ± 0.003 and 1.017 ± 0.004 for the 6 and 8 MeV beams, respectively. The most significant source of uncertainty in this study was the repeatability (type A, 0.42%). It is expected that performing fewer consecutive measurements under higher dose rate conditions will improve the stability of the thermal background, thereby improving the repeatability and reducing the overall standard uncertainty.

  7. Observation of thiamin-bound intermediates and microscopic rate constants for their interconversion on 1-deoxy-D-xylulose 5-phosphate synthase: 600-fold rate acceleration of pyruvate decarboxylation by D-glyceraldehyde-3-phosphate.

    PubMed

    Patel, Hetalben; Nemeria, Natalia S; Brammer, Leighanne A; Freel Meyers, Caren L; Jordan, Frank

    2012-11-07

    The thiamin diphosphate (ThDP)-dependent enzyme 1-deoxy-D-xylulose 5-phosphate (DXP) synthase carries out the condensation of pyruvate as a 2-hydroxyethyl donor with d-glyceraldehyde-3-phosphate (d-GAP) as acceptor forming DXP. Toward understanding catalysis of this potential anti-infective drug target, we examined the pathway of the enzyme using steady state and presteady state kinetic methods. It was found that DXP synthase stabilizes the ThDP-bound predecarboxylation intermediate formed between ThDP and pyruvate (C2α-lactylThDP or LThDP) in the absence of D-GAP, while addition of D-GAP enhanced the rate of decarboxylation by at least 600-fold. We postulate that decarboxylation requires formation of a ternary complex with both LThDP and D-GAP bound, and the central enzyme-bound enamine reacts with D-GAP to form DXP. This appears to be the first study of a ThDP enzyme where the individual rate constants could be evaluated by time-resolved circular dichroism spectroscopy, and the results could have relevance to other ThDP enzymes in which decarboxylation is coupled to a ligation reaction. The acceleration of the rate of decarboxylation of enzyme-bound LThDP in the presence of D-GAP suggests a new approach to inhibitor design.

  8. Late Pleistocene-Holocene acceleration of uplift rate in southwest Erromango Island, Southern Vanuatu, South Pacific: relation to the growth of the Vanuatuan Mid Sedimentary Basin

    SciTech Connect

    Neef, G.; Hendy, C.

    1988-07-01

    Late Quaternary and Holocene raised coral reefs are well developed in southwestern Erromango Island, which lies in the frontal arc area of the Vanuatuan Island Arc. Eight uranium series ages and one /sup 14/C age from samples from coral reefs at three localities range in age from 4800 B.P. to about 320,000 B.P. Six of the samples dated are from the Matiwo Point area. Here the youngest reef has given a /sup 230/Th//sup 234/U age of 4800 B.P. and a slightly older reef, 4.3 m higher in elevation, has a /sup 14/C age of 5270 B.P. Inland of a cliff the youngest three of four northeastward-tilted raised reefs have given /sup 230/Th//sup 234/U ages ranging from 104,000 B.P. to about 320,000 B.P. These data indicate accelerating uplift rates for southwest Erromango: during the periods 320,000-133,000 B.P., 133,000-6000 B.P., and 6000 - 0 B.P. average uplift rates were 0.33 mm/yr, 0.65 mm/yr, and about 1 mm/yr respectively. These data are interpreted to indicate the growth of the Mid Sedimentary Basin, which lies within the frontal and volcanic arc part of the island arc complex. This increase in uplift/eastward-tilting could represent a Quaternary-Late Pleistocene increase in the subduction rate of the Australian Plate beneath Erromango.

  9. The pad readout electronics of the SLD Warm Iron Calorimeter

    SciTech Connect

    Burrows, P.N.; Busza, W.; Cartwright, S.L.; Friedman, J.I.; Fuess, S.; Gonzalez, S.; Hansl-Kozanecka, T.; Kendall, H.W.; Lath, A.; Lyons, T.; Osborne, L.S.; Rosenson, L.; Schneekloth, U.; Taylor, F.E.; Verdier, R.; Wadsworth, B.; Williams, D.C.; Yamartino, J.M. ); Byers, B.L.; Escalera, J.; Gioumousis, A.; Gray, R.; Horelick, D.; Kharakh, D.; Messner, R.L.; Moss, J.; Zdark

    1990-08-01

    The design of the pad readout electronics of the Warm Iron Calorimeter for the SLD detector at SLAC, consisting of about 9000 analog channels, is described. Results of various tests performed during the construction, installation and commissioning of the electronics mounted on the detector are presented. 10 refs., 12 figs.

  10. Balloon test project: Cosmic Ray Antimatter Calorimeter (CRAC)

    NASA Technical Reports Server (NTRS)

    Christy, J. C.; Dhenain, G.; Goret, P.; Jorand, J.; Masse, P.; Mestreau, P.; Petrou, N.; Robin, A.

    1984-01-01

    Cosmic ray observations from balloon flights are discussed. The cosmic ray antimatter calorimeter (CRAC) experiment attempts to measure the flux of antimatter in the 200-600 Mev/m energy range and the isotopes of light elements between 600 and 1,000 Mev/m.

  11. Temperature and humidity control in indirect calorimeter chambers

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A three-chamber, indirect calorimeter has been a part of the Environmental Laboratory at the U.S. Meat Animal Research Center (MARC) for over 25 yr. Corrosion of the animal chambers and unreliable temperature control forced either major repairs or complete replacement. There is a strong demand for...

  12. Progress status for the Mu2e calorimeter system

    SciTech Connect

    Pezzullo, Gianantonio; Budagov, J.; Carosi, R.; Cervelli, F.; Cheng, C.; Cordelli, M.; Corradi, G.; Davydov, Yu.; Echenard, B.; Giovannella, S.; Glagolev, V.; Happacher, F.; Hitlin, D.; Luca, A.; Martini, M.; Miscetti, S.; Murat, P.; Ongmonkolkul, P.; Porter, F.; Saputi, A.; Sarra, I.; Spinella, F.; Stomaci, V.; Tassielli, G.

    2015-02-13

    The Mu2e experiment at FNAL aims to measure the charged-lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the muon rest mass (104.97 MeV). The calorimeter should confirm that the candidates reconstructed by the extremely precise tracker system are indeed conversion electrons while performing a powerful $\\mu/e$ particle identification. Moreover, it should also provide a high level trigger for the experiment independently from the tracker system. The calorimeter should also be able to keep functionality in an environment where the background delivers a dose of ~ 10 krad/year in the hottest area and to work in the presence of 1 T axial magnetic field. These requirements translate in the design of a calorimeter with large acceptance, good energy resolution O(5%) and a reasonable position (time) resolution of ~<1 cm (<0.5ns). The baseline version of the calorimeter is composed by two disks of inner (outer) radius of 351 (660) mm filled by 1860 hexagonal $BaF_2$ crystals of 20 cm length. Each crystal is readout by two large area APD's. In this study, we summarize the experimental tests done so far as well as the simulation studies in the Mu2e environment.

  13. Progress status for the Mu2e calorimeter system

    DOE PAGES

    Pezzullo, Gianantonio; Budagov, J.; Carosi, R.; ...

    2015-02-13

    The Mu2e experiment at FNAL aims to measure the charged-lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the muon rest mass (104.97 MeV). The calorimeter should confirm that the candidates reconstructed by the extremely precise tracker system are indeed conversion electrons while performing a powerfulmore » $$\\mu/e$$ particle identification. Moreover, it should also provide a high level trigger for the experiment independently from the tracker system. The calorimeter should also be able to keep functionality in an environment where the background delivers a dose of ~ 10 krad/year in the hottest area and to work in the presence of 1 T axial magnetic field. These requirements translate in the design of a calorimeter with large acceptance, good energy resolution O(5%) and a reasonable position (time) resolution of ~<1 cm (<0.5ns). The baseline version of the calorimeter is composed by two disks of inner (outer) radius of 351 (660) mm filled by 1860 hexagonal $$BaF_2$$ crystals of 20 cm length. Each crystal is readout by two large area APD's. In this study, we summarize the experimental tests done so far as well as the simulation studies in the Mu2e environment.« less

  14. A systematic study on the reactivity of different grades of charged Li[NixMnyCoz]O2 with electrolyte at elevated temperatures using accelerating rate calorimetry

    NASA Astrophysics Data System (ADS)

    Ma, Lin; Nie, Mengyun; Xia, Jian; Dahn, J. R.

    2016-09-01

    The reactivity between charged Li[NixMnyCoz]O2 (NMC, with x + y + z = 1, x:y:z = 1:1:1 (NMC111), 4:4:2 (NMC442), 5:3:2 (NMC532), 6:2:2 (NMC622) and 8:1:1 (NMC811)) and traditional carbonate-based electrolytes at elevated temperatures was systematically studied using accelerating rate calorimetry (ARC). The ARC results showed that the upper cut-off potential and NMC composition strongly affect the thermal stability of the various NMC grades when traditional carbonate-based electrolyte was used. Although higher cut-off potential and higher Ni content can help increase the energy density of lithium ion cells, these factors generally increase the reactivity between charged NMC and electrolyte at elevated temperatures. It is hoped that this report can be used to help guide the wise selection of NMC grade and upper cut-off potential to achieve high energy density Li-ion cells without seriously compromising cell safety.

  15. A new approach to the radio-far infrared correlation for non-calorimeter galaxies.

    NASA Astrophysics Data System (ADS)

    Niklas, S.; Beck, R.

    1997-04-01

    New radio continuum data for a sample of 74 spiral galaxies supports the calorimeter model of Voelk (1989A&A...218...67V) only for steep-spectrum, thin-disk, non-interacting objects which comprise =~30% of the sample. As the spectral indices correlate neither with far infrared surface brightness nor with average (equipartition) magnetic field strength, the data disagree with the model for non-calorimeter galaxies of Helou & Bicay (1993ApJ...415...93H). We are able to explain the radio - far infrared correlation for non-calorimeter galaxies, globally and also on kiloparsec scales within galaxies, with the help of two basic relations with the average volume density of the gas as the primary factor. Firstly, there is strong evidence that the strength of the equipartition magnetic field is correlated with the volume density ρ of the (almost) neutral gas, following a power law with an exponent of m=0.48+/-0.05 for the galactic averages of our sample. Secondly, taking the thermal radio emissivity as an indicator of the average star-formation rate (SFR), we obtain a `Schmidt law' (SFR{prop.to}ρ^n^) with n=1.4+/-0.3. The FIR luminosity is linearly related to SFR. Finally, we assume equipartition between the energy densities of the magnetic field and of the cosmic rays which relates the synchrotron emissivity to the field strength. Combination of these relations leads to a radio - far infrared luminosity correlation with a power-law exponent of x=1.3+/-0.3, very close to what is observed (x=1.25+/-0.08). Forthcoming ISO satellite data can be used as a test of our approach.

  16. Sensitive power compensated scanning calorimeter for analysis of phase transformations in small samples

    NASA Astrophysics Data System (ADS)

    Lopeandía, A. F.; Cerdó, L. l.; Clavaguera-Mora, M. T.; Arana, Leonel R.; Jensen, K. F.; Muñoz, F. J.; Rodríguez-Viejo, J.

    2005-06-01

    We have designed and developed a sensitive scanning calorimeter for use with microgram or submicrogram, thin film, or powder samples. Semiconductor processing techniques are used to fabricate membrane based microreactors with a small heat capacity of the addenda, 120nJ/K at room temperature. At heating rates below 10K/s the heat released or absorbed by the sample during a given transformation is compensated through a resistive Pt heater by a digital controller so that the calorimeter works as a power compensated device. Its use and dynamic sensitivity is demonstrated by analyzing the melting behavior of thin films of indium and high density polyethylene. Melting enthalpies in the range of 40-250μJ for sample masses on the order of 1.5μg have been measured with accuracy better than 5% at heating rates ˜0.2K/s. The signal-to-noise ratio, limited by the electronic setup, is 200nW.

  17. Isothermal crystallization kinetics of Poly (lactic acid) studied by ultrafast chip calorimeter

    NASA Astrophysics Data System (ADS)

    Jiang, Jing; Jiang, Wei; Huang, Zijie; Zhou, Dongshan; Xue, Gi

    2012-02-01

    Poly (lactic acid) (PLA) is a biocompatible, biodegradable polymer which has attracted much attention. The crystallization ability, as one of the most factors influencing the physical properties of the biomaterials such as thermal, mechanical, and biodegradable properties, has been widely studied mainly by differential scanning calorimeters. However, although the crystallization of PLA is relatively slow, it's difficult to avoid the crystallization from the nuclei or the structure reorganization of the metastable crystalline formed during the annealing process when we use the normal DSC with the heating rate on the level of tens of K/min. With the chip calorimeter whose scanning rate can go up to 1000 K/s, we can avoid the structure reorganization of metastable crystalline during the heating. In this case we annealed the PLA sample in the 80-120^oC temperature range and found the relationship between the onset the melting temperature Tm and crystallization temperature Tc is Tm= 0.53Tc+ 213.5 and the equilibrium melting temperature is Tm,f =179.6^oC.

  18. CsI Calorimeter for a Compton-Pair Telescope

    NASA Astrophysics Data System (ADS)

    Grove, Eric J.

    We propose to build and test a hodoscopic CsI(Tl) scintillating-crystal calorimeter for a medium-energy γ-ray Compton and pair telescope. The design and technical approach for this calorimeter relies deeply on heritage from the Fermi LAT CsI Calorimeter, but it dramatically improves the low-energy performance of that design by reading out the scintillation light with silicon photomultipliers (SiPMs), making the technology developed for Fermi applicable in the Compton regime. While such a hodoscopic calorimeter is useful for an entire class of medium-energy γ-ray telescope designs, we propose to build it explicitly to support beam tests and balloon flight of the Proto-ComPair telescope, the development and construction of which was funded in a four-year APRA program beginning in 2015 ("ComPair: Steps to a Medium Energy γ-ray Mission" with PI J. McEnery of GSFC). That award did not include funding for its CsI calorimeter subsystem, and this proposal is intended to cover that gap. ComPair is a MIDEX-class instrument concept to perform a high-sensitivity survey of the γ-ray sky from 0.5 MeV to 500 MeV. ComPair is designed to provide a dramatic increase in sensitivity relative to previous instruments in this energy range (predominantly INTEGRAL/SPI and Compton COMPTEL), with the same transformative sensitivity increase – and corresponding scientific return– that the Fermi Large Area Telescope provided relative to Compton EGRET. To enable transformative science over a broad range of MeV energies and with a wide field of view, ComPair is a combined Compton telescope and pair telescope employing a silicon-strip tracker (for Compton scattering and pair conversion and tracking) and a solid-state CdZnTe calorimeter (for Compton absorption) and CsI calorimeter (for pair calorimetry), surrounded by a plastic scintillator anti-coincidence detector. Under the current proposal, we will complete the detailed design, assembly, and test of the CsI calorimeter for the risk

  19. Future accelerators (?)

    SciTech Connect

    John Womersley

    2003-08-21

    I describe the future accelerator facilities that are currently foreseen for electroweak scale physics, neutrino physics, and nuclear structure. I will explore the physics justification for these machines, and suggest how the case for future accelerators can be made.

  20. Accelerated partial breast irradiation: An analysis of variables associated with late toxicity and long-term cosmetic outcome after high-dose-rate interstitial brachytherapy

    SciTech Connect

    Wazer, David E. . E-mail: dwazer@tufts-nemc.org; Kaufman, Seth; Cuttino, Laurie; Di Petrillo, Thomas; Arthur, Douglas W.

    2006-02-01

    Purpose: To perform a detailed analysis of variables associated with late tissue effects of high-dose-rate (HDR) interstitial brachytherapy accelerated partial breast irradiation (APBI) in a large cohort of patients with prolonged follow-up. Methods and Materials: Beginning in 1995, 75 women with Stage I/II breast cancer were enrolled in identical institutional trials evaluating APBI as monotherapy after lumpectomy. Patients eligible included those with T1-2, N0-1 ({<=}3 nodes positive), M0 tumors of nonlobular histology with negative surgical margins, no extracapsular nodal extension, and negative results on postexcision mammogram. All patients underwent surgical excision and postoperative irradiation with HDR interstitial brachytherapy. The planning target volume was defined as the excision cavity plus a 2-cm margin. Treatment was delivered with a high-activity Ir-192 source at 3.4 Gy per fraction twice daily for 5 days to a total dose of 34 Gy. Dosimetric analyses were performed with three-dimensional postimplant dose and volume reconstructions. All patients were evaluated at 3-6-month intervals and assessed with a standardized cosmetic rating scale and according to Radiation Therapy Oncology Group late normal tissue toxicity scoring criteria. Clinical and therapy-related features were analyzed for their relationship to cosmetic outcome and toxicity rating. Clinical features analyzed included age, volume of resection, history of diabetes or hypertension, extent of axillary surgery, and systemic therapies. Therapy-related features analyzed included volume of tissue encompassed by the 100%, 150%, and 200% isodose lines (V100, V150, and V200, respectively), the dose homogeneity index (DHI), number of source dwell positions, and planar separation. Results: The median follow-up of all patients was 73 months (range, 43-118 months). The cosmetic outcome at last follow-up was rated as excellent, good, and fair/poor in 67%, 24%, and 9% of patients, respectively

  1. Comparison of the Effects of Two Auditory Methods by Mother and Fetus on the Results of Non-Stress Test (Baseline Fetal Heart Rate and Number of Accelerations) in Pregnant Women: A Randomized Controlled Trial

    PubMed Central

    Khoshkholgh, Roghaie; Keshavarz, Tahereh; Moshfeghy, Zeinab; Akbarzadeh, Marzieh; Asadi, Nasrin; Zare, Najaf

    2016-01-01

    Objective: To compare the effects of two auditory methods by mother and fetus on the results of NST in 2011-2012. Materials and methods: In this single-blind clinical trial, 213 pregnant women with gestational age of 37-41 weeks who had no pregnancy complications were randomly divided into 3 groups (auditory intervention for mother, auditory intervention for fetus, and control) each containing 71 subjects. In the intervention groups, music was played through the second 10 minutes of NST. The three groups were compared regarding baseline fetal heart rate and number of accelerations in the first and second 10 minutes of NST. The data were analyzed using one-way ANOVA, Kruskal-Wallis, and paired T-test. Results: The results showed no significant difference among the three groups regarding baseline fetal heart rate in the first (p = 0.945) and second (p = 0.763) 10 minutes. However, a significant difference was found among the three groups concerning the number of accelerations in the second 10 minutes. Also, a significant difference was observed in the number of accelerations in the auditory intervention for mother (p = 0.013) and auditory intervention for fetus groups (p < 0.001). The difference between the number of accelerations in the first and second 10 minutes was also statistically significant (p = 0.002). Conclusion: Music intervention was effective in the number of accelerations which is the indicator of fetal health. Yet, further studies are required to be conducted on the issue. PMID:27385971

  2. Studies of Excess Heat and Convection in a Water Calorimeter.

    PubMed

    Domen, J K; Domen, S R

    2001-01-01

    To explain a difference of 0.5 % between the absorbed-dose standards of the National Institute of Standards and Technology (NIST) and the National Research Council of Canada (NRCC), Seuntjens et al. suggest the fault lies with the NIST water calorimeter being operated at 22 °C and the method with which the measurements were made. Their calculations show that this difference is due to overprediction of temperature rises of six consecutive (60)Co radiation runs at NIST. However, the consecutive runs they refer to were merely preliminary measurements to determine the procedure for the NIST beam calibration. The beam calibration was determined from only two consecutive runs followed by water circulation to re-establish temperature equilibrium. This procedure was used for measurements on 77 days, with 32 runs per day. Convection external to the glass cylindrical detector assembly performed a beneficial role. It aided (along with conduction) in increasing the rate of excess heat transported away from the thin cylindrical wall. This decreased the rate of heat conducted toward the axially located thermistors. The other sources of excess heat are the: (1) non-water materials in the temperature probe, and (2) exothermic effect of the once-distilled water external to the cylinder. Finite-element calculations were made to determine the separate and combined effects of the excess heat sources for the afterdrift. From this analysis, extrapolation of the measured afterdrifts of two consecutive runs to mid radiation leads to an estimated over-prediction of no more than about 0.1 %. Experimental measurements contradict the calculated results of Seuntjens et al. that convective motion (a plume) originates from the thermistors operated with an electrical power dissipation as low as 0.6 μW, well below the measured threshold of 50 μW. The method used for detecting a plume was sensitive enough to measure a convective plume (if it had started) down to about the 10 μW power level

  3. Studies of Excess Heat and Convection in a Water Calorimeter

    PubMed Central

    Domen, John K.; Domen, Steve R.

    2001-01-01

    To explain a difference of 0.5 % between the absorbed-dose standards of the National Institute of Standards and Technology (NIST) and the National Research Council of Canada (NRCC), Seuntjens et al. suggest the fault lies with the NIST water calorimeter being operated at 22 °C and the method with which the measurements were made. Their calculations show that this difference is due to overprediction of temperature rises of six consecutive 60Co radiation runs at NIST. However, the consecutive runs they refer to were merely preliminary measurements to determine the procedure for the NIST beam calibration. The beam calibration was determined from only two consecutive runs followed by water circulation to re-establish temperature equilibrium. This procedure was used for measurements on 77 days, with 32 runs per day. Convection external to the glass cylindrical detector assembly performed a beneficial role. It aided (along with conduction) in increasing the rate of excess heat transported away from the thin cylindrical wall. This decreased the rate of heat conducted toward the axially located thermistors. The other sources of excess heat are the: (1) non-water materials in the temperature probe, and (2) exothermic effect of the once-distilled water external to the cylinder. Finite-element calculations were made to determine the separate and combined effects of the excess heat sources for the afterdrift. From this analysis, extrapolation of the measured afterdrifts of two consecutive runs to mid radiation leads to an estimated over-prediction of no more than about 0.1 %. Experimental measurements contradict the calculated results of Seuntjens et al. that convective motion (a plume) originates from the thermistors operated with an electrical power dissipation as low as 0.6 μW, well below the measured threshold of 50 μW. The method used for detecting a plume was sensitive enough to measure a convective plume (if it had started) down to about the 10 μW power level

  4. Status of the Level 0 Trigger Processor of the NA62 Liquid Krypton Electromagnetic Calorimeter

    NASA Astrophysics Data System (ADS)

    Bonaiuto, V.; de Simone, N.; Federici, L.; Sargeni, F.; Badoni, D.; Fucci, A.; Paoluzzi, G.; Salamon, A.; Salina, G.; Santovetti, E.; Checcucci, B.; Papi, A.; Piccini, M.; Bizzarri, M.; Venditti, S.

    2014-06-01

    The NA62 experiment at the CERN SPS aims to measure the Branching Ratio of the ultra-rare decay K^+ rightarrow π^+νbarν, collecting about 100 events in two years of data taking with a signal to background ratio of 10:1. A hermetic photon veto system has been designed to efficiently reject the π0 background, one of the main background sources, and the 20-ton liquid krypton calorimeter is a fundamental component of such system in the angular acceptance region 1-10 mrad. In this paper, we present the design of the Level 0 trigger processor that is able to identify electromagnetic clusters in the calorimeter providing information on time, position and energy reconstruction for each cluster. In particular, it is composed of 36 readout boards (TEL62), organized in a three layer parallel system, 108 mezzanines and 215 high-performance FPGAs. The system has been designed to sustain an instantaneous hit rate of 40 MHz, to process data with a latency of about 100 μs, and to achieve a time resolution of 1.5 ns on the single cluster. Performance and functionality test results of a trigger slice, together with an updated status report of the whole level 0 trigger project, will be presented.

  5. Development of COTS ADC SEE Test System for the ATLAS LArCalorimeter Upgrade

    DOE PAGES

    Hu, Xue -Ye; Chen, Hu -Cheng; Chen, Kai; ...

    2014-12-01

    Radiation-tolerant, high speed, high density and low power commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are planned to be used in the upgrade to the Liquid Argon (LAr) calorimeter front end (FE) trigger readout electronics. Total ionization dose (TID) and single event effect (SEE) are two important radiation effects which need to be characterized on COTS ADCs. In our initial TID test, Texas Instruments (TI) ADS5272 was identified to be the top performer after screening a total 17 COTS ADCs from different manufacturers with dynamic range and sampling rate meeting the requirements of the FE electronics. Another interesting feature of ADS5272more » is its 6.5 clock cycles latency, which is the shortest among the 17 candidates. Based on the TID performance, we have designed a SEE evaluation system for ADS5272, which allows us to further assess its radiation tolerance. In this paper, we present a detailed design of ADS5272 SEE evaluation system and show the effectiveness of this system while evaluating ADS5272 SEE characteristics in multiple irradiation tests. According to TID and SEE test results, ADS5272 was chosen to be implemented in the full-size LAr Trigger Digitizer Board (LTDB) demonstrator, which will be installed on ATLAS calorimeter during the 2014 Long Shutdown 1 (LS1).« less

  6. Development of COTS ADC SEE Test System for the ATLAS LArCalorimeter Upgrade

    SciTech Connect

    Hu, Xue -Ye; Chen, Hu -Cheng; Chen, Kai; Mead, Joseph; Liu, Shu -Bin; An, Qi

    2014-12-01

    Radiation-tolerant, high speed, high density and low power commercial off-the-shelf (COTS) analog-to-digital converters (ADCs) are planned to be used in the upgrade to the Liquid Argon (LAr) calorimeter front end (FE) trigger readout electronics. Total ionization dose (TID) and single event effect (SEE) are two important radiation effects which need to be characterized on COTS ADCs. In our initial TID test, Texas Instruments (TI) ADS5272 was identified to be the top performer after screening a total 17 COTS ADCs from different manufacturers with dynamic range and sampling rate meeting the requirements of the FE electronics. Another interesting feature of ADS5272 is its 6.5 clock cycles latency, which is the shortest among the 17 candidates. Based on the TID performance, we have designed a SEE evaluation system for ADS5272, which allows us to further assess its radiation tolerance. In this paper, we present a detailed design of ADS5272 SEE evaluation system and show the effectiveness of this system while evaluating ADS5272 SEE characteristics in multiple irradiation tests. According to TID and SEE test results, ADS5272 was chosen to be implemented in the full-size LAr Trigger Digitizer Board (LTDB) demonstrator, which will be installed on ATLAS calorimeter during the 2014 Long Shutdown 1 (LS1).

  7. Thermal Capacitance (Slug) Calorimeter Theory Including Heat Losses and Other Decaying Processes

    NASA Technical Reports Server (NTRS)

    Hightower, T. Mark; Olivares, Ricardo A.; Philippidis, Daniel

    2008-01-01

    A mathematical model, termed the Slug Loss Model, has been developed for describing thermal capacitance (slug) calorimeter behavior when heat losses and other decaying processes are not negligible. This model results in the temperature time slope taking the mathematical form of exponential decay. When data is found to fit well to this model, it allows a heat flux value to be calculated that corrects for the losses and may be a better estimate of the cold wall fully catalytic heat flux, as is desired in arc jet testing. The model was applied to the data from a copper slug calorimeter inserted during a particularly severe high heating rate arc jet run to illustrate its use. The Slug Loss Model gave a cold wall heat flux 15% higher than the value of 2,250 W/sq cm obtained from the conventional approach to processing the data (where no correction is made for losses). For comparison, a Finite Element Analysis (FEA) model was created and applied to the same data, where conduction heat losses from the slug were simulated. The heat flux determined by the FEA model was found to be in close agreement with the heat flux determined by the Slug Loss Model.

  8. Micro-differential scanning calorimeter for liquid biological samples

    NASA Astrophysics Data System (ADS)

    Wang, Shuyu; Yu, Shifeng; Siedler, Michael S.; Ihnat, Peter M.; Filoti, Dana I.; Lu, Ming; Zuo, Lei

    2016-10-01

    We developed an ultrasensitive micro-DSC (differential scanning calorimeter) for liquid protein sample characterization. This design integrated vanadium oxide thermistors and flexible polymer substrates with microfluidics chambers to achieve a high sensitivity (6 V/W), low thermal conductivity (0.7 mW/K), high power resolutions (40 nW), and well-defined liquid volume (1 μl) calorimeter sensor in a compact and cost-effective way. We further demonstrated the performance of the sensor with lysozyme unfolding. The measured transition temperature and enthalpy change were in accordance with the previous literature data. This micro-DSC could potentially raise the prospect of high-throughput biochemical measurement by parallel operation with miniaturized sample consumption.

  9. Micro-differential scanning calorimeter for liquid biological samples

    SciTech Connect

    Wang, Shuyu; Yu, Shifeng; Siedler, Michael S.; Ihnat, Peter M.; Filoti, Dana I.; Lu, Ming; Zuo, Lei

    2016-10-20

    Here, we developed an ultrasensitive micro-DSC (differential scanning calorimeter) for liquid protein sample characterization. Our design integrated vanadium oxide thermistors and flexible polymer substrates with microfluidics chambers to achieve a high sensitivity (6 V/W), low thermal conductivity (0.7 mW/K), high power resolutions (40 nW), and well-defined liquid volume (1 μl) calorimeter sensor in a compact and cost-effective way. Furthermore, we demonstrated the performance of the sensor with lysozyme unfolding. The measured transition temperature and enthalpy change were in accordance with the previous literature data. This micro-DSC could potentially raise the prospect of high-throughput biochemical measurement by parallel operation with miniaturized sample consumption.

  10. Experience with a double-compensating beam calorimeter

    SciTech Connect

    Jarmie, N.; Brown, R.E.; Hardekopf, R.A.; Martinez, R.

    1982-01-01

    In an experiment to measure the D(t,..cap alpha..)n cross section at beam energies of 10 to 120 keV, we have developed a double-compensating beam calorimeter, based on a Swiss design to measure the partical beam intensity. A Faraday cup is not useful because of considerable charge exchange in the target gas at such low beam energies. We calibrated the calorimeter both with 10- and 3-MeV protons (comparing with a Faraday-cup measurement of the beam flux) and with the heat generated in a precision resistor. Both methods agree and give a calibration accurate to +- 0.08% over a range of 10 to 800 mW beam power. Beam powers as low as 5 mW may be used, but with less accuracy. The beam energy must be known in order to calculate the particle intensity. Some difficulties with and peculiarities of the device are discussed.

  11. Geometric calibration of the SND detector electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Korol, A. A.; Melnikova, N. A.

    2017-03-01

    This paper presents the design, implementation and validation of the software alignment procedure used to perform geometric calibration of the electromagnetic calorimeter with respect to the tracking system of the SND detector which is taking data at the VEPP-2000 e+e- collider (BINP, Novosibirsk). This procedure is based on the mathematical model describing the relative calorimeter position. The parameter values are determined by minimizing a χ2 function using the difference between particle directions reconstructed in these two subdetectors for e+e- →e+e- scattering events. The results of the calibration applied to data and MC simulation fit the model well and give an improvement in particle reconstruction. They are used in data reconstruction and MC simulation.

  12. Micro-differential scanning calorimeter for liquid biological samples

    DOE PAGES

    Wang, Shuyu; Yu, Shifeng; Siedler, Michael S.; ...

    2016-10-20

    Here, we developed an ultrasensitive micro-DSC (differential scanning calorimeter) for liquid protein sample characterization. Our design integrated vanadium oxide thermistors and flexible polymer substrates with microfluidics chambers to achieve a high sensitivity (6 V/W), low thermal conductivity (0.7 mW/K), high power resolutions (40 nW), and well-defined liquid volume (1 μl) calorimeter sensor in a compact and cost-effective way. Furthermore, we demonstrated the performance of the sensor with lysozyme unfolding. The measured transition temperature and enthalpy change were in accordance with the previous literature data. This micro-DSC could potentially raise the prospect of high-throughput biochemical measurement by parallel operation with miniaturizedmore » sample consumption.« less

  13. Boronated Scintillator Detector for Use in Space with Ionization Calorimeters

    NASA Astrophysics Data System (ADS)

    Britvich, G. I.; Chernichenko, S. K.; Demichev, M. A.; Gnezdilov, I. I.; Mukhin, V. I.; Soukhih, A. V.

    2016-02-01

    Boronated Scintillator Detector (BSD) for use in space with ionization calorimeters was suggested. BSD improved e/h showers separation, which are initiated in the ionization calorimeter in interaction it with high energy particles. Improve the rejection is based on the hadron-induced showers tend to be accompanied by significantly more neutron activity than electromagnetic showers. The detector is composed of natural boron-loaded (5%) castable plastic scintillation plates. To collect light using wavelength-shifting (WLS) fibers. The experiment showed that the photoelectron yield is ∼ 40 ph.el./MeV with using PMT EMI 9954KB. Simulation on GEANT4 was obtained neutron detection efficiency. The simulation was conducted in the assumption that neutrons have the spectrum 252Cf and fall plane-parallel on the entry surface of the detector.

  14. Active radiometric calorimeter for absolute calibration of radioactive sources

    SciTech Connect

    Stump, K.E.; DeWerd, L.A.; Rudman, D.A.; Schima, S.A.

    2005-03-01

    This report describes the design and initial noise floor measurements of a radiometric calorimeter designed to measure therapeutic medical radioactive sources. The instrument demonstrates a noise floor of approximately 2 nW. This low noise floor is achieved by using high temperature superconducting (HTS) transition edge sensor (TES) thermometers in a temperature-control feedback loop. This feedback loop will be used to provide absolute source calibrations based upon the electrical substitution method. Other unique features of the calorimeter are (a) its ability to change sources for calibration without disrupting the vacuum of the instrument, and (b) the ability to measure the emitted power of a source in addition to the total contained source power.

  15. The iMPACT project tracker and calorimeter

    NASA Astrophysics Data System (ADS)

    Mattiazzo, S.; Bisello, D.; Giubilato, P.; Pantano, D.; Pozzobon, N.; Snoeys, W.

    2017-02-01

    In recent years the use of hadrons for cancer radiation treatment has grown in importance, and many facilities are currently operational or under construction worldwide. To fully exploit the therapeutic advantages offered by hadron therapy, precise body imaging for accurate beam delivery is decisive. While traditional X-ray Computed Tomography (xCT) fails in providing 3D images with the precision required for hadrons treatment guidance, Proton Computer Tomography (pCT) scanners, currently in their R&D phase, can. A pCT scanner consists of a tracker system, to track protons, and of a calorimeter, to measure their residual energy. In this paper we will present the iMPACT project, which foresees a novel proton tracking detector with higher scanning speed, better spatial resolution and lower material budget with respect to present state-of-the-art detectors, leading to enhanced performances. The tracker will be matched to a fast, highly segmented proton range calorimeter.

  16. On timing properties of LYSO-based calorimeters

    SciTech Connect

    Anderson, D.; Apresyan, A.; Bornheim, A.; Duarte, J.; Pena, C.; Ronzhin, A.; Spiropulu, M.; Trevor, J.; Xie, S.

    2015-04-23

    We present test beam studies and results on the timing performance and characterization of the time resolution of Lutetium–Yttrium Orthosilicate (LYSO)-based calorimeters. We also demonstrate that a time resolution of 30 ps is achievable for a particular design. Additionally, we discuss precision timing calorimetry as a tool for the mitigation of physics object performance degradation effects due to the large number of simultaneous interactions in the high luminosity environment foreseen at the Large Hadron Collider.

  17. Design of a microwave calorimeter for the microwave tokamak experiment

    SciTech Connect

    Marinak, M. )

    1988-10-07

    The initial design of a microwave calorimeter for the Microwave Tokamak Experiment is presented. The design is optimized to measure the refraction and absorption of millimeter rf microwaves as they traverse the toroidal plasma of the Alcator C tokamak. Techniques utilized can be adapted for use in measuring high intensity pulsed output from a microwave device in an environment of ultra high vacuum, intense fields of ionizing and non-ionizing radiation and intense magnetic fields. 16 refs.

  18. Micro-Fabricated DC Comparison Calorimeter for RF Power Measurement

    PubMed Central

    Neji, Bilel; Xu, Jing; Titus, Albert H.; Meltzer, Joel

    2014-01-01

    Diode detection and bolometric detection have been widely used to measure radio frequency (RF) power. However, flow calorimeters, in particular micro-fabricated flow calorimeters, have been mostly unexplored as power meters. This paper presents the design, micro-fabrication and characterization of a flow calorimeter. This novel device is capable of measuring power from 100 μW to 200 mW. It has a 50-Ohm load that is heated by the RF source, and the heat is transferred to fluid in a microchannel. The temperature change in the fluid is measured by a thermistor that is connected in one leg of a Wheatstone bridge. The output voltage change of the bridge corresponds to the RF power applied to the load. The microfabricated device measures 25.4 mm × 50.8 mm, excluding the power supplies, microcontroller and fluid pump. Experiments demonstrate that the micro-fabricated sensor has a sensitivity up to 22 × 10−3 V/W. The typical resolution of this micro-calorimeter is on the order of 50 μW, and the best resolution is around 10 μW. The effective efficiency is 99.9% from 0–1 GHz and more than 97.5% at frequencies up to 4 GHz. The measured reflection coefficient of the 50-Ohm load and coplanar wave guide is less than −25 dB from 0–2 GHz and less than −16 dB at 2–4 GHz. PMID:25350509

  19. The large-scale anisotropy with the PAMELA calorimeter

    NASA Astrophysics Data System (ADS)

    Karelin, A.; Adriani, O.; Barbarino, G.; Bazilevskaya, G.; Bellotti, R.; Boezio, M.; Bogomolov, E.; Bongi, M.; Bonvicini, V.; Bottai, S.; Bruno, A.; Cafagna, F.; Campana, D.; Carbone, R.; Carlson, P.; Casolino, M.; Castellini, G.; De Donato, C.; De Santis, C.; De Simone, N.; Di Felice, V.; Formato, V.; Galper, A.; Koldashov, S.; Koldobskiy, S.; Krut'kov, S.; Kvashnin, A.; Leonov, A.; Malakhov, V.; Marcelli, L.; Martucci, M.; Mayorov, A.; Menn, W.; Mergé, M.; Mikhailov, V.; Mocchiutti, E.; Monaco, A.; Mori, N.; Munini, R.; Osteria, G.; Palma, F.; Panico, B.; Papini, P.; Pearce, M.; Picozza, P.; Ricci, M.; Ricciarini, S.; Sarkar, R.; Simon, M.; Scotti, V.; Sparvoli, R.; Spillantini, P.; Stozhkov, Y.; Vacchi, A.; Vannuccini, E.; Vasilyev, G.; Voronov, S.; Yurkin, Y.; Zampa, G.; Zampa, N.

    2015-10-01

    The large-scale anisotropy (or the so-called star-diurnal wave) has been studied using the calorimeter of the space-born experiment PAMELA. The cosmic ray anisotropy has been obtained for the Southern and Northern hemispheres simultaneously in the equatorial coordinate system for the time period 2006-2014. The dipole amplitude and phase have been measured for energies 1-20 TeV n-1.

  20. After-burning of nitropenta products in a calorimeter

    SciTech Connect

    Kuhl, A L; Neuwald, P; Reichenbach, H

    1999-06-18

    Explored here are the ''after-burning'' effects for explosions of Nitropenta (NP) charges in air. Detonation of the charge transforms the solid explosive ( C HNO 5 8412 , also known as PETN) into gaseous products that are rich in carbon and CO, which subsequently act as a fuel. When these hot ({approximately}3500 K) gases mix with air, rapid combustion (after-burning) takes place. The dynamics of this exothermic process was studied in ''pressure calorimeter'' experiments performed at EMI.

  1. An electromagnetic calorimeter for the JLab real compton scattering experiment

    NASA Astrophysics Data System (ADS)

    Hamilton, D. J.; Shahinyan, A.; Wojtsekhowski, B.; Annand, J. R. M.; Chang, T.-H.; Chudakov, E.; Danagoulian, A.; Degtyarenko, P.; Egiyan, K.; Gilman, R.; Gorbenko, V.; Hines, J.; Hovhannisyan, E.; Hyde-Wright, C. E.; de Jager, C. W.; Ketikyan, A.; Mamyan, V. H.; Michaels, R.; Nathan, A. M.; Nelyubin, V.; Rachek, I.; Roedelbrom, M.; Petrosyan, A.; Pomatsalyuk, R.; Popov, V.; Segal, J.; Shestakov, Y.; Templon, J.; Voskanyan, H.

    2011-07-01

    A lead-glass hodoscope calorimeter that was constructed for use in the Jefferson Lab Real Compton Scattering experiment is described. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6%/ √{Eγ GeV}. Features of both the detector design and its performance in the high luminosity environment during the experiment are presented.

  2. Calibration and Characterization of the Small Sample Calorimeter

    SciTech Connect

    Santi, Peter A.; Perry, Katherine A.

    2012-08-13

    An early component of the Joint Fuel Cycle Study (JFCS) between the United States and the Republic of Korea is a test of gram scale electrochemical recycling of spent fuel which is to be performed at Idaho National Laboratory (INL). Included in this test is the development of Nondestructive Assay (NDA) technologies that would be applicable for International Atomic Energy Agency (IAEA) safeguards of the electrochemical recycling process. Of upmost importance to safeguarding the fuel cycle associated with the electrochemical recycling process is the ability to safeguard the U/TRU ingots that will be produced in the process. For the gram scale test, the ingots that will be produced will have an expected thermal power of approximately 130 mW. To ascertain how well the calorimetric assay NDA technique can perform in assaying these ingots, Los Alamos National Laboratory (LANL) has characterized and calibrated a small solid-state calorimeter called the Small Sample Calorimeter (SSC3) to perform these measurements at LANL. To calibrate and characterize the SSC3, a series of measurements were performed using certified {sup 238}Pu heat standards whose power output is traceable back to the National Institute of Standards and Technology (NIST) electrical standards. The results of these measurements helped establish both the calibration of the calorimeter as well as the expected performance of the calorimeter in terms of its accuracy and precision as a function of thermal power of the item that is being measured. In this report, we will describe the measurements that were performed and provide a discussion of the results of these measurements.

  3. The backward end-cap for the PANDA electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Capozza, L.; Maas, F. E.; Noll, O.; Rodriguez Pineiro, D.; Valente, R.

    2015-02-01

    The PANDA experiment at the new FAIR facility will cover a broad experimental programme in hadron structure and spectroscopy. As a multipurpose detector, the PANDA spectrometer needs to ensure almost 4π coverage of the scattering solid angle, full and accurate multiple-particle event reconstruction and very good particle identification capabilities. The electromagnetic calorimeter (EMC) will be a key item for many of these aspects. Particle energies ranging from some MeVs to several GeVs have to be measured with a relative resolution of 1% ⊕ 2%/√E/GeV . It will be a homogeneous calorimeter made of PbWO4 crystals and will be operated at -25°C, in order to improve the scintillation light yield. With the exception of the very forward section, the light will be detected by large area avalanche photodiodes (APDs). The current pulses from the APDs will be integrated, amplified and shaped by ASIC chips which were developed for this purpose. The whole calorimeter has been designed in three sections: a forward end-cap, a central barrel and a backward end-cap (BWEC). In this contribution, a status report on the development of the BWEC is presented.

  4. Hadronic Showers in a Highly Granular Imaging Calorimeter

    NASA Astrophysics Data System (ADS)

    Kaplan, A.; The Calice Collaboration

    The CALICE collaboration develops highly granular calorimeter prototypes to evaluate technologies for experiments at a future lepton collider. The analogue hadronic calorimeter prototype consists of steel absorber plates interleaved with 38 active plastic scintillator layers which are sub-divided into small tiles. In total 7608 tiles are read out individually via embedded Silicon Photomultipliers. The prototype is one of the first large scale applications of these novel and very promising miniature photodetectors. Since 2006, the calorimeter has been operated in combined test beam setups at DESY, CERN and FNAL. The high-resolution 3D image data with analogue energy information are used to study properties and composition of hadronic showers at a new level of detail. This helps to constrain hadronic shower models through comparisons with model calculations. The spatial shower development and the substructure of the showers, compared to a variety of different Geant 4 shower models including decompositions into individual shower components are presented. Aspects of the energy reconstruction of hadronic showers, such as Particle Flow, are discussed.

  5. Electromagnetic Calorimeter studies for the GEp(5) experiment

    NASA Astrophysics Data System (ADS)

    Ayerbe Gayoso, Carlos

    2013-10-01

    The GEp(5) experiment, part of the SBS collaboration, will be the fourth measurement of the GEp /GMp ratio using the proton recoil polarization technique. The current data suggests that the GEp /GMp ratio obtained with this technique, might cross zero near Q2 ~ 10 GeV2 , now reachable with the CEBAF upgrade to 12 GeV energy beam. This measurement technique requires a precise measurement of the energy and angles of the scattered electron in coincidence with the recoil proton. The electron's measured energy and crude position will be used in the trigger, while the offline position measurement will be used in kinematic cuts to separate the elastic process from the background. A lead-glass calorimeter, which was used in the previous experiments, is not optimal for the planned experiment due to the rapid radiation damage in the experiment's running conditions. A sampling calorimeter, made of lead and plastic scintillators, is under consideration. Results from a test beam and Monte Carlo simulations of this kind of calorimeter will be presented. Supported from a NSF grant, PHY-1066374.

  6. Applying fast calorimetry on a spent nuclear fuel calorimeter

    SciTech Connect

    Liljenfeldt, Henrik

    2015-04-15

    Recently at Los Alamos National Laboratory, sophisticated prediction algorithms have been considered for the use of calorimetry for treaty verification. These algorithms aim to predict the equilibrium temperature based on early data and therefore be able to shorten the measurement time while maintaining good accuracy. The algorithms have been implemented in MATLAB and applied on existing equilibrium measurements from a spent nuclear fuel calorimeter located at the Swedish nuclear fuel interim storage facility. The results show significant improvements in measurement time in the order of 15 to 50 compared to equilibrium measurements, but cannot predict the heat accurately in less time than the currently used temperature increase method can. This Is both due to uncertainties in the calibration of the method as well as identified design features of the calorimeter that limits the usefulness of equilibrium type measurements. The conclusions of these findings are discussed, and suggestions of both improvements of the current calorimeter as well as what to keep in mind in a new design are given.

  7. The calorimeter of the Mu2e experiment at Fermilab

    DOE PAGES

    Atanov, N.; Baranov, V.; Budagov, J.; ...

    2017-01-23

    Here, the Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: amore » straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10-4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.« less

  8. The calorimeter of the Mu2e experiment at Fermilab

    NASA Astrophysics Data System (ADS)

    Atanov, N.; Baranov, V.; Budagov, J.; Cervelli, F.; Colao, F.; Cordelli, M.; Corradi, G.; Dané, E.; Davydov, Y. I.; Di Falco, S.; Diociaiuti, E.; Donati, S.; Donghia, R.; Echenard, B.; Flood, K.; Giovannella, S.; Glagolev, V.; Grancagnolo, F.; Happacher, F.; Hitlin, D. G.; Martini, M.; Miscetti, S.; Miyashita, T.; Morescalchi, L.; Murat, P.; Pezzullo, G.; Porter, F.; Raffaelli, F.; Radicioni, T.; Ricci, M.; Saputi, A.; Sarra, I.; Spinella, F.; Tassielli, G.; Tereshchenko, V.; Usubov, Z.; Zhu, R. Y.

    2017-01-01

    The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: a straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10‑4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.

  9. A photon calorimeter using lead tungstate crystals for the CEBAF HAll A Compton polarimeter

    SciTech Connect

    D. Neyret; T. Pussieux; T. Auger; M. Baylac; E. Burtin; C. Cavata; R. Chipaux; S. Escoffier; N. Falletto; J. Jardillier; S. Kerhoas; D. Lhuillier; F. Marie; C. Veyssiere; J. Ahrens; R. Beck; M. Lang

    2000-05-01

    A new Compton polarimeter is built on the CEBAF Hall A electron beam line. Performances of 10% resolution and 1% calibration are required for the photon calorimeter of this polarimeter. This calorimeter is built with lead tungstate scintillators coming from the CMS electromagnetic calorimeter R&D. Beam tests of this detector have been made using the tagged photon beam line at MAMI, Mainz, and a resolution of 1.76%+2.75%/v+0.41%/E has been measured.

  10. Precision closed bomb calorimeter for testing flame and gas producing initiators

    NASA Technical Reports Server (NTRS)

    Carpenter, D. R., Jr.; Taylor, A. C., Jr.

    1972-01-01

    A calorimeter has been developed under this study to help meet the needs of accurate performance monitoring of electrically or mechanically actuated flame and gas producing devices, such as squib-type initiators. A ten cubic centimeter closed bomb (closed volume) calorimeter was designed to provide a standard pressure trace and to measure a nominal 50 calorie output, using the basic components of a Parr Model 1411 calorimeter. Two prototype bombs were fabricated, pressure tested to 2600 psi, and extensively evaluated.

  11. Tests of the D0 calorimeter response in 2--150 GeV beams

    SciTech Connect

    De, K. . Dept. of Physics)

    1992-10-01

    At the heart of the D0 detector, which recently started its maiden data run at the Fermilab Tevatron p[bar p] collider, is a finely segmented hermetic large angle liquid argon calorimeter. We present here results from the latest test beam studies of the calorimeter in 1991. Modules from the central calorimeter, end calorimeter and the inter-cryostat detector were included in this run. New results on resolution, uniformity and linearity will be presented with electron and pion beams of various energies. Special emphasis will be placed on first results from the innovative technique of using scintillator sampling in the intermediate rapidity region to improve uniformity and hermeticity.

  12. Tests of the D0 calorimeter response in 2--150 GeV beams

    SciTech Connect

    De, K.; D0 Collaboration

    1992-10-01

    At the heart of the D0 detector, which recently started its maiden data run at the Fermilab Tevatron p{bar p} collider, is a finely segmented hermetic large angle liquid argon calorimeter. We present here results from the latest test beam studies of the calorimeter in 1991. Modules from the central calorimeter, end calorimeter and the inter-cryostat detector were included in this run. New results on resolution, uniformity and linearity will be presented with electron and pion beams of various energies. Special emphasis will be placed on first results from the innovative technique of using scintillator sampling in the intermediate rapidity region to improve uniformity and hermeticity.

  13. VHDL implementation of feature-extraction algorithm for the PANDA electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Guliyev, E.; Kavatsyuk, M.; Lemmens, P. J. J.; Tambave, G.; Löhner, H.; Panda Collaboration

    2012-02-01

    A simple, efficient, and robust feature-extraction algorithm, developed for the digital front-end electronics of the electromagnetic calorimeter of the PANDA spectrometer at FAIR, Darmstadt, is implemented in VHDL for a commercial 16 bit 100 MHz sampling ADC. The source-code is available as an open-source project and is adaptable for other projects and sampling ADCs. Best performance with different types of signal sources can be achieved through flexible parameter selection. The on-line data-processing in FPGA enables to construct an almost dead-time free data acquisition system which is successfully evaluated as a first step towards building a complete trigger-less readout chain. Prototype setups are studied to determine the dead-time of the implemented algorithm, the rate of false triggering, timing performance, and event correlations.

  14. Theoretical Noise Analysis on a Position-sensitive Metallic Magnetic Calorimeter

    NASA Technical Reports Server (NTRS)

    Smith, Stephen J.

    2007-01-01

    We report on the theoretical noise analysis for a position-sensitive Metallic Magnetic Calorimeter (MMC), consisting of MMC read-out at both ends of a large X-ray absorber. Such devices are under consideration as alternatives to other cryogenic technologies for future X-ray astronomy missions. We use a finite-element model (FEM) to numerically calculate the signal and noise response at the detector outputs and investigate the correlations between the noise measured at each MMC coupled by the absorber. We then calculate, using the optimal filter concept, the theoretical energy and position resolution across the detector and discuss the trade-offs involved in optimizing the detector design for energy resolution, position resolution and count rate. The results show, theoretically, the position-sensitive MMC concept offers impressive spectral and spatial resolving capabilities compared to pixel arrays and similar position-sensitive cryogenic technologies using Transition Edge Sensor (TES) read-out.

  15. LINEAR ACCELERATOR

    DOEpatents

    Colgate, S.A.

    1958-05-27

    An improvement is presented in linear accelerators for charged particles with respect to the stable focusing of the particle beam. The improvement consists of providing a radial electric field transverse to the accelerating electric fields and angularly introducing the beam of particles in the field. The results of the foregoing is to achieve a beam which spirals about the axis of the acceleration path. The combination of the electric fields and angular motion of the particles cooperate to provide a stable and focused particle beam.

  16. Implementation of Constant Dose Rate and Constant Angular Spacing Intensity-modulated Arc Therapy for Cervical Cancer by Using a Conventional Linear Accelerator

    PubMed Central

    Zhang, Ruo-Hui; Fan, Xiao-Mei; Bai, Wen-Wen; Cao, Yan-Kun

    2016-01-01

    Background: Volumetric-modulated arc therapy (VMAT) can only be implemented on the new generation linacs such as the Varian Trilogy® and Elekta Synergy®. This prevents most existing linacs from delivering VMAT. The purpose of this study was to investigate the feasibility of using a conventional linear accelerator delivering constant dose rate and constant angular spacing intensity-modulated arc therapy (CDR-CAS-IMAT) for treating cervical cancer. Methods: Twenty patients with cervical cancer previously treated with intensity-modulated radiation therapy (IMRT) using Varian Clinical 23EX were retreated using CDR-CAS-IMAT. The planning target volume (PTV) was set as 50.4 Gy in 28 fractions. Plans were evaluated based on the ability to meet the dose volume histogram. The homogeneity index (HI), target volume conformity index (CI), the dose to organs at risk, radiation delivery time, and monitor units (MUs) were also compared. The paired t-test was used to analyze the two data sets. All statistical analyses were performed using SPSS 19.0 software. Results: Compared to the IMRT group, the CDR-CAS-IMAT group showed better PTV CI (0.85 ± 0.03 vs. 0.81 ± 0.03, P = 0.001), clinical target volume CI (0.46 ± 0.05 vs. 0.43 ± 0.05, P = 0.001), HI (0.09±0.02 vs. 0.11 ± 0.02, P = 0.005) and D95 (5196.33 ± 28.24 cGy vs. 5162.63 ± 31.12 cGy, P = 0.000), and cord D2 (3743.8 ± 118.7 cGy vs. 3806.2 ± 98.7 cGy, P = 0.017) and rectum V40 (41.9 ± 6.1% vs. 44.2 ± 4.8%, P = 0.026). Treatment time (422.7 ± 46.7 s vs. 84.6 ± 7.8 s, P = 0.000) and the total plan Mus (927.4 ± 79.1 vs. 787.5 ± 78.5, P = 0.000) decreased by a factor of 0.8 and 0.15, respectively. The IMRT group plans were superior to the CDR-CAS-IMAT group plans considering decreasing bladder V50 (17.4 ± 4.5% vs. 16.6 ± 4.2%, P = 0.049), bowel V30 (39.6 ± 6.5% vs. 36.6 ± 7.5%, P = 0.008), and low-dose irradiation volume; there were no significant differences in other statistical indexes. Conclusions

  17. Upgrade of the Trigger Readout System of the ATLAS Liquid Argon Calorimeters

    NASA Astrophysics Data System (ADS)

    Marino, C. P.

    2014-06-01

    The ATLAS detector was designed and built to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV and instantaneous luminosities up to 1034cm-2s-1. Liquid argon (LAr) sampling calorimeters are employed for all electromagnetic calorimetry in the pseudorapidity region |η| <3.2, and for hadronic calorimetry in the region from |η| =1.5 to |η| =4.9. The ATLAS LAr calorimeters produce a total of 182,486 signals which are digitized and processed by the front-end and back-end electronics at every triggered event. In addition, the front-end electronics sums analog signals to provide coarsely grained energy sums to the Level-1 trigger system, which is optimized for nominal LHC luminosities. In 2018, an instantaneous luminosity of 2-3 ×1034cm-2s-1 is expected, far beyond the nominal one for which the detector was designed. In order to cope with this increased trigger rate, an improved spatial granularity of the trigger primitives is proposed to improve the identification performance for trigger signatures, like electrons, photons, tau leptons, jets, total and missing energy, at high background rejection rates. For these purposes, a new LAr Trigger Digitizer Board (LTDB) is being designed to receive higher granularity signals, digitize them on detector and send them via fast optical links to a new LAr digital processing system (LDPS). The LDPS applies a digital filtering and identifies significant energy depositions in each trigger channel. The refined trigger primitives are then transmitted to the Level-1 trigger system to extract improved trigger signatures.

  18. Acceleration switch

    DOEpatents

    Abbin, Jr., Joseph P.; Devaney, Howard F.; Hake, Lewis W.

    1982-08-17

    The disclosure relates to an improved integrating acceleration switch of the type having a mass suspended within a fluid filled chamber, with the motion of the mass initially opposed by a spring and subsequently not so opposed.

  19. Acceleration switch

    DOEpatents

    Abbin, J.P. Jr.; Devaney, H.F.; Hake, L.W.

    1979-08-29

    The disclosure relates to an improved integrating acceleration switch of the type having a mass suspended within a fluid filled chamber, with the motion of the mass initially opposed by a spring and subsequently not so opposed.

  20. ION ACCELERATOR

    DOEpatents

    Bell, J.S.

    1959-09-15

    An arrangement for the drift tubes in a linear accelerator is described whereby each drift tube acts to shield the particles from the influence of the accelerating field and focuses the particles passing through the tube. In one embodiment the drift tube is splii longitudinally into quadrants supported along the axis of the accelerator by webs from a yoke, the quadrants. webs, and yoke being of magnetic material. A magnetic focusing action is produced by energizing a winding on each web to set up a magnetic field between adjacent quadrants. In the other embodiment the quadrants are electrically insulated from each other and have opposite polarity voltages on adjacent quadrants to provide an electric focusing fleld for the particles, with the quadrants spaced sufficienily close enough to shield the particles within the tube from the accelerating electric field.

  1. Statistical correlation of the soil incubation and the accelerated laboratory extraction methods to estimate nitrogen release rates of slow- and controlled-release fertilizers.

    PubMed

    Medina, L Carolina; Sartain, Jerry; Obreza, Thomas; Leary, Emily; Hall, William L; Thiex, Nancy J

    2014-01-01

    Several technologies have been proposed to characterize the nutrient release patterns of enhanced-efficiency fertilizers (EEFs) during the last few decades. These technologies have been developed mainly by manufacturers and are product-specific based on the regulation and analysis of each EEF product. Despite previous efforts to characterize nutrient release of slow-release fertilizer (SRF) and controlled-release fertilizer (CRF) materials, no official method exists to assess their nutrient release patterns. However, the increased production and distribution of EEFs in specialty and nonspecialty markets requires an appropriate method to verify nutrient claims and material performance. Nonlinear regression was used to establish a correlation between the data generated from a 180-day soil incubation-column leaching procedure and 74 h accelerated lab extraction method, and to develop a model that can predict the 180-day nitrogen (N) release curve for a specific SRF and CRF product based on the data from the accelerated laboratory extraction method. Based on the R2 > 0.90 obtained for most materials, results indicated that the data generated from the 74 h accelerated lab extraction method could be used to predict N release from the selected materials during 180 days, including those fertilizers that require biological activity for N release.

  2. LINEAR ACCELERATOR

    DOEpatents

    Christofilos, N.C.; Polk, I.J.

    1959-02-17

    Improvements in linear particle accelerators are described. A drift tube system for a linear ion accelerator reduces gap capacity between adjacent drift tube ends. This is accomplished by reducing the ratio of the diameter of the drift tube to the diameter of the resonant cavity. Concentration of magnetic field intensity at the longitudinal midpoint of the external sunface of each drift tube is reduced by increasing the external drift tube diameter at the longitudinal center region.

  3. Measuring the short-term substrate utilization response to high-carbohydrate and high-fat meals in the whole-body indirect calorimeter.

    PubMed

    Gribok, Andrei; Leger, Jayme L; Stevens, Michelle; Hoyt, Reed; Buller, Mark; Rumpler, William

    2016-06-01

    The paper demonstrates that minute-to-minute metabolic response to meals with different macronutrient content can be measured and discerned in the whole-body indirect calorimeter. The ability to discriminate between high-carbohydrate and high-fat meals is achieved by applying a modified regularization technique with additional constraints imposed on oxygen consumption rate. These additional constraints reduce the differences in accuracy between the oxygen and carbon dioxide analyzers. The modified technique was applied to 63 calorimeter sessions that were each 24 h long. The data were collected from 16 healthy volunteers (eight males, eight females, aged 22-35 years). Each volunteer performed four 24-h long calorimeter sessions. At each session, they received one of four treatment combinations involving exercise (high or low intensity) and diet (a high-fat or high-carbohydrate shake for lunch). One volunteer did not complete all four assignments, which brought the total number of sessions to 63 instead of 64. During the 24-h stay in the calorimeter, subjects wore a continuous glucose monitoring system, which was used as a benchmark for subject's postprandial glycemic response. The minute-by-minute respiratory exchange ratio (RER) data showed excellent agreement with concurrent subcutaneous glucose concentrations in postprandial state. The averaged minute-to-minute RER response to the high-carbohydrate shake was significantly different from the response to high-fat shake. Also, postprandial RER slopes were significantly different for two dietary treatments. The results show that whole-body respiration calorimeters can be utilized as tools to study short-term kinetics of substrate oxidation in humans.

  4. Combination of best promoter and micellar catalyst for more than kilo-fold rate acceleration in favor of chromic acid oxidation of D-galactose to D-galactonic acid in aqueous media at room temperature

    NASA Astrophysics Data System (ADS)

    Saha, Rumpa; Ghosh, Aniruddha; Sar, Pintu; Saha, Indrajit; Ghosh, Sumanta K.; Mukherjee, Kakali; Saha, Bidyut

    2013-12-01

    Picolinic acid, 2,2‧-bipyridine and 1,10-phenanthroline promoted Cr(VI) oxidation of D-galactose to D-galactonic acid in three representative aqueous micellar media has been studied. The anionic surfactant (SDS) accelerated the rate of reaction while the cationic surfactant (CPC) and neutral surfactant (TX-100) retarded the reaction rate. Combination of bipy and SDS is the best choice for chromic acid oxidation of D-galactose to D-galactonic acid in aqueous media although 1,10-phenanthroline is best promoter in absence of micellar catalyst.

  5. TECHNICAL DESIGN REPORT FOR A NOSECONE CALORIMETER (NCC) FOR THE PHENIX EXPERIMENT.

    SciTech Connect

    PHENIX EXPERIMENT; OBRIEN,E.; BOOSE, S.; CHIU, M.; JOHNSON, B.M.; KISTENEV, E.P.; LYNCH, D.; NOUICER, R.; PAK, R.; PISANI, R.; STOLL, S.P.; SUKHANOV, A.; WOODY, C.L.; LI, Z.; RADEKA, V.; RESCIA, S.

    2007-08-01

    A remarkable result has emerged from the first several years of data taking at RHIC--the high temperature and density phase of QCD matter created in heavy ion collisions at RHIC is best described as a near perfect fluid--the strongly interacting Quark-Gluon-Plasma (sQGP). This state is characterized by a small viscosity to entropy ratio, and a high density of color charges which induces huge energy losses of partons transversing the medium. The task for the future is to understand the characteristics of the sQGP, and perhaps more importantly--to gain some insight into how and why such a medium is created. The PHENIX detector has been one of the primary experimental tools at RHIC; in particular the electromagnetic calorimeter has been a critical component of many of the measurements leading to this discovery. The coverage of the present PHENIX electromagnetic calorimeter is rather limited, covering half the azimuth and -0.35< {eta} <0.35 Further progress requires larger coverage of electromagnetic calorimetry, both to increase the rate for low cross section phenomena, and to cover a broader range of pseudorapidity to study the rapidity dependence of the medium. A pair of Nosecone Calorimeters (NCC) has been designed covering both positive and negative rapidity regions 1< |{eta}| <3 of the PHENIX detector. The NCC will make it possible to perform tomographic studies of the jet energy dependence of energy loss and medium response, by using direct photons as trigger particles over a large rapidity range. The technique of correlating trigger hadrons with low momentum hadrons has been powerfully exploited at RHIC to study the evolution of back to back jets [1, 2] and hence the response of the medium. The NCC will make it possible to do such studies using direct photons as the trigger particles. The direct photon in such ''photon-jet'' events tags the transverse momentum of outgoing parton which then fragments into lower energy particles. Together with the Forward Silicon

  6. Monte-Carlo Simulations of the Nuclear Energy Deposition Inside the CARMEN-1P Differential Calorimeter Irradiated into OSIRIS Reactor

    SciTech Connect

    Amharrak, H.; Reynard-Carette, C.; Carette, M.; Lemaire, M.; Vaglio-Gaudard, C.; Fourmentel, D.; Lyoussi, A.

    2015-07-01

    The nuclear heating measurements in Material Testing Reactors (MTRs) are crucial for the study of nuclear materials and fuels under irradiation. The reference measurements of this nuclear heating are especially performed by a differential calorimeter including a graphite sample material. These measurements are then used for other experimental conditions in order to predict the nuclear heating and thermal conditions induced in the irradiation devices. Nuclear heating is a great deal of interest at the moment as the measurement of such heating is an important issue for MTRs reactors. This need is especially generated by the new Jules Horowitz Reactor (JHR), under construction at CEA/Cadarache 'French Alternative Energies and Atomic Energy Commission'. This new reactor, that will be operational in late 2019, is a new facility for the nuclear research on materials and fuels. Indeed the expected nuclear heating rate is about 20 W/g for nominal capacity of 100 MW. The present Monte Carlo calculation works belong to the IN-CORE (Instrumentation for Nuclear radiation and Calorimetry On line in Reactor): a joint research program between the CEA and Aix- Marseille University in 2009. One scientific aim of this program is to design and develop a multi-sensors device, called CARMEN, dedicated to the measurements of main physical parameters simultaneously encountered inside JHR's experimental channels (core and reflector) such as neutron fluxes, photon fluxes, temperature, and nuclear heating. A first prototype was already developed. This prototype includes two mock-ups dedicated respectively to neutronic measurements (CARMEN-1N) and to photonic measurements (CARMEN-1P) with in particular a specific differential calorimeter. Two irradiation campaigns were performed successfully in the periphery of OSIRIS reactor (a MTR located at Saclay, France) in 2012 for nuclear heating levels up to 2 W/g. First Monte Carlo calculations reduced to the graphite sample of the calorimeter were

  7. Determination of the total absorption peak in an electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Cheng, Jia-Hua; Wang, Zhe; Lebanowski, Logan; Lin, Guey-Lin; Chen, Shaomin

    2016-08-01

    A physically motivated function was developed to accurately determine the total absorption peak in an electromagnetic calorimeter and to overcome biases present in many commonly used methods. The function is the convolution of a detector resolution function with the sum of a delta function, which represents the complete absorption of energy, and a tail function, which describes the partial absorption of energy and depends on the detector materials and structures. Its performance was tested with the simulation of three typical cases. The accuracy of the extracted peak value, resolution, and peak area was improved by an order of magnitude on average, relative to the Crystal Ball function.

  8. Calorimeter and related calculations for the Superconducting Super Collider

    SciTech Connect

    Gabriel, T.A.

    1989-02-01

    There are four topics to be covered in this paper. The first topic deals with the programs, the models, and the cross sections in the CALOR code package. Secondly, a discussion on compensating calorimetry as it applies to Fe/Si and U/Si calorimetry will be given. Thirdly, calculated results obtained on U/Si calorimeters using the CALOR system will be presented and discussed. Finally, the calculations that the Oak Ridge National Laboratory are carrying out dealing with radiation damage at the proposed Superconducting Super Collider (SSC) are described. 23 refs., 9 figs.

  9. Performance of the Advanced Thin Ionization Calorimeter (ATIC)

    NASA Technical Reports Server (NTRS)

    Case, G.; Ellison, S.; Gould, R.; Granger, D.; Guzik, T. G.; Isbert, J.; Price, B.; Stewart, M.; Wefel, J. P.; Adams, J. H.; Rose, M. Franklin (Technical Monitor)

    2001-01-01

    The ATIC instrument is a balloon-borne experiment capable of measuring cosmic ray elemental spectra from 50 GeV to 100 TeV for nuclei from H to Fe with a fully active Bismuth Germanate calorimeter. Several Long Duration Balloon flights from McMurdo station, Antarctica are scheduled. The detector was tested with high energy electron, proton, and pion beams at CERN. We present results for 150 and 375 GeV protons, and 150 GeV pions and comparison with a GEANT Monte Carlo.

  10. Data acquisition system for the CALICE AHCAL calorimeter

    NASA Astrophysics Data System (ADS)

    Kvasnicka, J.

    2017-03-01

    The data acquisition system (DAQ) for a highly granular analogue hadron calorimeter (AHCAL) for the future International Linear Collider is presented. The developed DAQ chain has several stages of aggregation and scales up to 8 million channels foreseen for the AHCAL detector design. The largest aggregation device, Link Data Aggregator, has 96 HDMI connectors, four Kintex7 FPGAs and a central Zynq System-On-Chip. Architecture and performance results are shown in detail. Experience from DESY testbeams with a small detector prototype consisting of 15 detector layers are shown.

  11. Analysis of diagnostic calorimeter data by the transfer function technique

    SciTech Connect

    Delogu, R. S. Pimazzoni, A.; Serianni, G.; Poggi, C.; Rossi, G.

    2016-02-15

    This paper describes the analysis procedure applied to the thermal measurements on the rear side of a carbon fibre composite calorimeter with the purpose of reconstructing the energy flux due to an ion beam colliding on the front side. The method is based on the transfer function technique and allows a fast analysis by means of the fast Fourier transform algorithm. Its efficacy has been tested both on simulated and measured temperature profiles: in all cases, the energy flux features are well reproduced and beamlets are well resolved. Limits and restrictions of the method are also discussed, providing strategies to handle issues related to signal noise and digital processing.

  12. Design and development of the SDC barrel electromagnetic calorimeter

    SciTech Connect

    Ambats, I.; Balka, L.; Blair, R.

    1994-04-01

    In fulfillment of contract SSC92-W-17743, Argonne National Laboratory is required to closeout and document all work performed in the design and development of the central calorimeter for the Solenoidal Detector Collaboration (SDC) Detector at the Superconducting Super Collider Laboratory (SSCL). This report will summarize the work performed, and identify all documents (technical reports, memo`s, drawings, etc.) that resulted from that effort. The work under this contract was shared in collaboration with the Westinghouse Science and Technology Center (WSTC) of Pittsburgh, Pennsylvania. It is the intent of this report to provide information that can be useful in the development of future detectors for high energy physics particle research.

  13. Studies of hadron-electron separators for the ZEUS barrel calorimeter

    SciTech Connect

    Ambats, I.; Bortz, D.; Connolly, A.

    1995-05-25

    Two possible upgrades, a shower maximum detector and a presampler, designed to improve the low energy electron/hadron separation capabilities of the ZEUS barrel calorimeter are described and test-beam results are reported. The presampler can also be used to correct for energy loss of particles traversing the dead material in front of the calorimeter.

  14. Test and evaluation of an Argonne National Laboratory bulk assay calorimeter

    SciTech Connect

    Rodenburg, W.W.; Fellers, C.L.; Lemming, J.F.

    1981-06-30

    The Argonne National Laboratory bulk assay calorimeter (BAC) was subjected to a series of tests, using plutonium-238 heat standards, to evaluate the performance of the calorimeter over its operating range. The results of these tests provide baseline information of the instrument performance under laboratory conditions.

  15. Twin solution calorimeter determines heats of formation of alloys at high temperatures

    NASA Technical Reports Server (NTRS)

    Darby, J. B., Jr.; Kleb, R.; Kleppa, O. J.

    1968-01-01

    Calvert-type, twin liquid metal solution calorimeter determines the heats of formation of transition metal alloys at high temperatures. The twin differential calorimeter measures the small heat effects generated over extended periods of time, has maximum operating temperature of 1073 degrees K and an automatic data recording system.

  16. Comparison of thin-film resistance heat-transfer gages with thin-skin transient calorimeter gages in conventional hypersonic wind tunnels

    NASA Technical Reports Server (NTRS)

    Miller, C. G., III

    1981-01-01

    Thin film gages deposited at the stagnation region of small (8.1-mm-diameter) hemispheres and gages mounted flush with the surface of a sharp-leading-edge flat plate were tested in the Langley continuous-flow hypersonic tunnel and in the Langley hypersonic CF4 tunnel. Two substrate materials were tested, quartz and a machinable glass-ceramic. Small hemispheres were also tested utilizing the thin-skin transient calorimeter technique usually employed in conventional tunnels. One transient calorimeter model was a thin shell of stainless steel, and the other was a thin-skin insert of stainless steel mounted into a hemisphere fabricated from a machinable-glass-ceramic. Measured heat-transfer rates from the various hemispheres were compared with one another and with predicted rates. The results demonstrate the feasibility and advantages of using-film resistance heat-transfer gages in conventional hypersonic wind tunnels over a wide range of conditions.

  17. Performance of Prototypes for the Barrel Part of the ANDA Electromagnetic Calorimeter

    NASA Astrophysics Data System (ADS)

    Rosenbaum, Christoph; Diehl, S.; Dormenev, V.; Drexler, P.; Kavatsyuk, M.; Kuske, T.; Nazarenko, S.; Novotny, R.; Rosier, P.; Ryazantsev, A.; Wieczorek, P.; Wilms, A.; Zaunick, H.-G.; P¯ANDA Collaboration

    2016-08-01

    The performance of the most recent prototypes of the ANDA barrel electromagnetic calorimeter (EMC) will be compared. The first large scale prototype PROTO60 was designed to test the performance of the improved tapered lead tungstate crystals (PWO-II). The PROTO60 which consists of 6 × 10 crystals was tested at various accelerator facilities over the complete envisaged energy range fulfilling the requirements of the TDR of the ANDA EMC in terms of energy, position and time resolution. To realize the final barrel geometry and to test the final front end electronics, a second prototype PROTO120 has been constructed. It represents a larger section of a barrel slice, containing the most tapered crystals and the close to final components for the ANDA EMC. The performance of both prototypes will be compared with a focus on the analysis procedure including the signal extraction, noise rejection, calibration and the energy resolution. In addition, the influence of the non-uniformity of the crystal on the energy resolution will be discussed.

  18. A wire calorimeter for the SPIDER beam: Experimental tests and feasibility study

    SciTech Connect

    Pasqualotto, R. Serianni, G.; Veltri, P.; Cervaro, V.; Fasolo, D.; Mario, I.; Zanini, M.

    2015-04-08

    To study and optimize negative ion production and acceleration, in view of the use of neutral beam injectors in the ITER project, the SPIDER test facility (particle energy 100keV; beam current 50A, distributed over 1280 beamlets) is under construction in Padova, with the aim of testing beam characteristics and to verify the source proper operation, by means of several diagnostic systems. An array of tungsten wires, directly exposed to the beam and consequently heated to high temperature, is used in similar experiments at IPP-Garching to study the beam optics, which is one of the most important issues, in a qualitative way. The present contribution gives a description of an experimental investigation of the behavior of tungsten wires under high heat loads in vacuum. Samples of tungsten wires are heated by electrical currents and the emitted light is measured by a camera in the 400-1100nm wavelength range, which is proposed as a calibration tool. Simultaneously, the voltage applied to the wire is measured to study the dependency of emissivity on temperature. The feasibility study of a wire calorimeter for SPIDER is finally proposed; to this purpose, the expected behaviour of tungsten with the two-dimensional beam profile in SPIDER is numerically addressed.

  19. Radiation hardness of plastic scintillators for the Tile Calorimeter of the ATLAS detector

    NASA Astrophysics Data System (ADS)

    Jivan, H.; Mellado, B.; Sideras-Haddad, E.; Erasmus, R.; Liao, S.; Madhuku, M.; Peters, G.; Solvyanov, O.

    2015-06-01

    The radiation damage in polyvinyl toluene based plastic scintillator EJ200 obtained from ELJEN technology was investigated. This forms part of a comparative study conducted to aid in the upgrade of the Tile Calorimeter of the ATLAS detector during which the Gap scintillators will be replaced. Samples subjected to 6 MeV proton irradiation using the tandem accelerator of iThemba LABS, were irradiated with doses of approximately 0.8 MGy, 8 MGy, 25 MGy and 80 MGy. The optical properties were investigated using transmission spectroscopy whilst structural damage was assessed using Raman spectroscopy. Findings indicate that for the dose of 0.8 MGy, no structural damage occurs but a breakdown in the light transfer between base and fluor dopants is observed. For doses of 8 MGy to 80 MGy, structural damage leads to hydrogen loss in the benzene ring of the PVT base which forms free radicals. This results in an additional absorptive component causing increased transmission loss as dose is increased.

  20. A wire calorimeter for the SPIDER beam: Experimental tests and feasibility study

    NASA Astrophysics Data System (ADS)

    Pasqualotto, R.; Serianni, G.; Mario, I.; Veltri, P.; Zanini, M.; Cervaro, V.; Fasolo, D.

    2015-04-01

    To study and optimize negative ion production and acceleration, in view of the use of neutral beam injectors in the ITER project, the SPIDER test facility (particle energy 100keV; beam current 50A, distributed over 1280 beamlets) is under construction in Padova, with the aim of testing beam characteristics and to verify the source proper operation, by means of several diagnostic systems. An array of tungsten wires, directly exposed to the beam and consequently heated to high temperature, is used in similar experiments at IPP-Garching to study the beam optics, which is one of the most important issues, in a qualitative way. The present contribution gives a description of an experimental investigation of the behavior of tungsten wires under high heat loads in vacuum. Samples of tungsten wires are heated by electrical currents and the emitted light is measured by a camera in the 400-1100nm wavelength range, which is proposed as a calibration tool. Simultaneously, the voltage applied to the wire is measured to study the dependency of emissivity on temperature. The feasibility study of a wire calorimeter for SPIDER is finally proposed; to this purpose, the expected behaviour of tungsten with the two-dimensional beam profile in SPIDER is numerically addressed.

  1. Radiation hardness of plastic scintillators for the Tile Calorimeter of the ATLAS detector

    NASA Astrophysics Data System (ADS)

    Jivan, H.; Sideras-Haddad, E.; Erasmus, R.; Liao, S.; Madhuku, M.; Peters, G.; Sekonya, K.; Solvyanov, O.

    2015-10-01

    The radiation damage in polyvinyl toluene based plastic scintillator EJ200 obtained from ELJEN technology was investigated. This forms part of a comparative study conducted to aid in the upgrade of the Tile Calorimeter of the ATLAS detector during which the Gap scintillators will be replaced. Samples subjected to 6 MeV proton irradiation using the tandem accelerator of iThemba LABS, were irradiated with doses of approximately 0.8 MGy, 8 MGy, 25 MGy and 80 MGy. The optical properties were investigated using transmission spectroscopy and light yield analysis whilst structural damage was assessed using Raman spectroscopy. Findings indicate that for the dose of 0.8 MGy, no structural damage occurs and light loss can be attributed to a breakdown in the light transfer between base and fluor dopants. For doses of 8 MGy to 80 MGy, structural damage leads to possible hydrogen loss in the benzene ring of the PVT base which forms free radicals. This results in an additional absorptive component causing increased transmission loss and light yield loss with increasing dose.

  2. Construction of a hadron calorimeter for Jefferson Lab Hall-A Super Bigbite Spectrometer

    NASA Astrophysics Data System (ADS)

    Mamyan, Vahe

    2015-04-01

    A ``shashlik'' hadron calorimeter is being constructed for the new Super Bigbite Spectrometer in Jefferson Lab Hall-A. The calorimeter will be used in nucleon-coincidence form-factor experiments taking advantage of Jefferson Labs' 12 GeV upgrade. An adiabatic light guide has been developed for the calorimeter based on laser cut acrylic sheets. A prototype module has been built to measure time resolution of the calorimeter for cosmic ray muons as well as to validate the Geant4 simulation. Several innovations in the calorimeter design will be discussed, in particular the choice of the scintillator, wave length shifter and the construction process of the light. The results of prototype tests is compared with Geant4 simulation for cosmic ray muons and prediction of HCal time and special resolution for hadrons in the 2-10 GeV/c momentum range will be presented. SBS COLLABORATION.

  3. Irradiation study of UV Silicon Photomultipliers for the Mu2e calorimeter

    NASA Astrophysics Data System (ADS)

    Baccaro, S.; Cemmi, A.; Cordelli, M.; Diociaiuti, E.; Donghia, R.; Ferrari, A.; Giovannella, S.; Loreti, S.; Miscetti, S.; Müller, S.; Pillon, M.; Sarra, I.

    2017-02-01

    The Mu2e calorimeter is composed of 1400 un-doped CsI crystals, coupled to large area UV extended Silicon Photomultipliers (SiPMs), arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position resolutions. It should also be fast enough to handle the high rate background and it must operate and survive in the high radiation environment. Simulation studies estimated that, in the highest irradiated regions, each photo-sensor will absorb a dose of 20 krad and will be exposed to a neutron fluency of 5.5×1011n1 MeV/cm2 in three years of running, with a safety factor of 3 included. At the end of 2015, we have concluded an irradiation campaign at the Frascati Neutron Generator (FNG, Frascati, Italy) measuring the response of two different 16 array models from Hamamatsu, which differ for the protection windows and a SiPM from FBK. In 2016, we have carried out two additional irradiation campaigns with neutrons and photons at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR, Dresden, Germany) and at the Calliope gamma irradiation facility at ENEA-Casaccia, respectively. A negligible increment of the leakage current and no gain change have been observed with the dose irradiation. On the other hand, at the end of the neutron irradiation, the gain does not show large changes whilst the leakage current increases by around a factor of 2000. In these conditions, the too high leakage current makes problematic to bias the SiPMs, thus requiring to cool them down to a running temperature of ~0oC.

  4. Compressor Calorimeter Test of R-410A Alternatives R-32, DR-5, and L-41a

    SciTech Connect

    Shrestha, Som S; Mahderekal, Isaac; Sharma, Vishaldeep; Abdelaziz, Omar

    2013-02-01

    As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares performance of alternative refrigerants R32, DR-5, and L-41A to that of refrigerant R-410A (baseline) in a scroll compressor designed for air-conditioning and heat pump applications. Compressor calorimeter tests were performed to evaluate the performance of the lower-GWP alternative refrigerants in place of the common refrigerant R-410A in a 36,000 Btu/hr compressor calorimeter using a compressor having a nominal rated capacity of 21,300 Btu/hr. Tests were conducted over a suction dew point temperature range of 10 F to 55 F in 5 F increments and a discharge dew point temperature range of 70 F to 140 F in 10 F increments. All the tests were performed with 20 F superheat, 40 F superheat and 65 F suction temperature. A liquid subcooling level of 15 F was maintained for all the test conditions. The tests showed that performance of these three lower-GWP alternative refrigerants is comparable to that of R-410A. For the 20 F superheat and 15 F subcooling test conditions, EERs of R32, DR-5, and L-41A were 90% to 99%, 96% to 99%, and 94% to 101%, respectively, compared to that of R-410A. Similarly, cooling capacities of R32, DR-5, and L-41A were 98% to 103%, 92% to 96%, and 84% to 92%, respectively, compared to that of R-410A.

  5. Cryogenic Tests of the ATLAS Liquid Argon Calorimeter

    NASA Astrophysics Data System (ADS)

    Bremer, J.; Chalifour, M.; Fabre, C.; Gonidec, A.; Passardi, G.

    2006-04-01

    The ATLAS liquid argon calorimeter consists of the barrel and two end-cap detectors housed in three independent cryostats filled with a total volume of 78 m3 of liquid argon. During cool-down the temperature differences in the composite structure of the detectors must be kept within strict limits to avoid excessive mechanical stresses and relative displacements. During normal operation the formation of gas bubbles, which are detrimental to the functioning of the detector, must be prevented and temperature gradients of less than 0.7 K across the argon bath are mandatory due to the temperature dependence of the energy measurements. Between April 2004 and May 2005 the barrel (120 t) and one end-cap (219 t) underwent qualification tests at the operating temperature of 87.3 K using a dedicated test facility at ground level. These tests provided a validation of the cooling methods to be adopted in the final underground configuration. In total 6.9 GJ and 15.7 GJ were extracted from the calorimeters and a temperature uniformity of the argon bath of less than 0.4 K was achieved.

  6. LED Monitoring System of the Phenix Muon Piston Calorimeter

    NASA Astrophysics Data System (ADS)

    Motschwiller, Steven

    2010-11-01

    The Muon Piston Calorimeter in the PHENIX experiment at RHIC has a monitoring system consisting of LEDs and PIN diodes to calibrate out the time dependent changes to the detector. The LEDs track the temperature and radiation-damage changes to the response of the MPC, while the absolute calibration can be done using 0̂ decays. To execute this, LEDs flash light through the PbWO4 crystal to the Avalanche Photo Diodes The MPC is made up of 416 independent electromagnetic calorimeter towers. By using the LEDs we can correct for changes in the gains of each tower in the MPC, on a run by run basis. Because the LED value only gives a relative measurement of the gain over time, this method of calibration can only be used in conjunction with absolute calibrations provided by 0̂ decays or by minimum ionizing peaks . This work will be used to make a final measurement on Transverse energy at √sNN = 200 GV in Au+Au collisions.

  7. Calibration and Monitoring of the CMS Electromagnetic Calorimeter

    NASA Astrophysics Data System (ADS)

    La Licata, C.

    2014-06-01

    The CMS Electromagnetic Calorimeter (ECAL) is a homogeneous and hermetic calorimeter with high granularity and fast response, designed to provide high resolution measurements of electron and photon energy. Precise calibration of the ECAL must be performed in situ at the LHC, in order to achieve and maintain its design performance and to fully exploit the physics reach of CMS. Several techniques have been developed for the intercalibration of ECAL using collision data. These methods are based on the reconstruction of the invariant mass peak of unconverted photons from low mass particle decays (π0and η) and on the azimuthal symmetry of the average energy deposition at a given pseudorapidity. Further intercalibration is carried out by using isolated electrons from W and Z bosons decays to compare the energy measured in ECAL to the momentum of the reconstructed tracks. The absolute calibration of the energy scale is performed using Z decays into electron-positron pairs. Changes in the ECAL response due to crystal radiation damage and changes in photo-detector output must be monitored. A system based on the injection of laser light into each crystal is used to track and correct for these variations during LHC operations.

  8. Unix version of CALOR89 for calorimeter applications

    SciTech Connect

    Handler, T.; Job, P.K.; Price, L.E.; Gabriel, T.A.

    1992-05-12

    CALOR89 is a system of coupled Monte Carlo particle transport computer codes which has been successfully employed for the estimation of calorimeter parameters in High Energy Physics. In the past CALOR89 has been running on various IBM machines and on CRAY X-MP at Lawrence Livermore Lab. These machines had non-unix operating systems. In this report we present a UNIX version of CALOR89, which is especially suited for the UNIX work stations. Moreover CALOR89 is also been supplemented with two new program packages which makes it more user friendly. CALPREP is a program for the preparation of the input files for CALOR89 in general geometry and ANALYZ is an analysis package to extract the final results from CALOR89 relevant to calorimeters. This report also provides two script files LCALOR and PCALOR. LCALOR runs CALOR89 sequences of programs and EGS4 for a given configuration sequentially on a single processor and PCALOR concurrently on a multiprocessor unix workstation.

  9. Floating data acquisition system for microwave calorimeter measurements on MTX

    SciTech Connect

    Sewall, N.R.; Meassick, S. )

    1989-09-13

    A microwave calorimeter has been designed for making 140-GHz absorption measurements on the MTX. Measurement of the intensity and spatial distribution of the FEL-generated microwave beam on the inner wall will indicate the absorption characteristics of the plasma when heated with a 140 GHz FEL pulse. The calorimeter works by monitoring changes of temperature in silicon carbide tiles located on the inner wall of the tokamak. Thermistors are used to measure the temperature of each tile. The tiles are located inside the tokamak about 1 cm outside of the limiter radius at machine potential. The success of this measurement depends on our ability to float the data acquisition system near machine potential and isolate it from the rest of the vault ground system. Our data acquisition system has 48 channels of thermistor signal conditioning, a multiplexer and digitizer section, a serial data formatter, and a fiber-optic transmitter to send the data out. Additionally, we bring timing signals to the interface through optical fibers to tell it when to begin measurement, while maintaining isolation. The receiver is an HP 200 series computer with a serial data interface; the computer provides storage and local display for the shot temperature profile. Additionally, the computer provides temporary storage of the data until it can be passed to a shared resource management system for archiving. 2 refs., 6 figs.

  10. New calorimeters for space experiments: physics requirements and technological challenges

    NASA Astrophysics Data System (ADS)

    Marrocchesi, Pier Simone

    2015-07-01

    Direct measurements of charged cosmic radiation with instruments in Low Earth Orbit (LEO), or flying on balloons above the atmosphere, require the identification of the incident particle, the measurement of its energy and possibly the determination of its sign-of-charge. The latter information can be provided by a magnetic spectrometer together with a measurement of momentum. However, magnetic deflection in space experiments is at present limited to values of the Maximum Detectable Rigidity (MDR) hardly exceeding a few TV. Advanced calorimetric techniques are, at present, the only way to measure charged and neutral radiation at higher energies in the multi-TeV range. Despite their mass limitation, calorimeters may achieve a large geometric factor and provide an adequate proton background rejection factor, taking advantage of a fine granularity and imaging capabilities. In this lecture, after a brief introduction on electromagnetic and hadronic calorimetry, an innovative approach to the design of a space-borne, large acceptance, homogeneous calorimeter for the detection of high energy cosmic rays will be described.

  11. π0 Reconstruction using the Muon Piston Calorimeter Extension

    NASA Astrophysics Data System (ADS)

    Dixit, Dhruv; Phenix Collaboration

    2015-10-01

    The Muon-Piston Calorimeter Extension (MPC-EX) is a new detector in the PHENIX experiment at the Relativistic Heavy Ion Collider that was installed for the recent Run 15 of the experiment. In polarized p+p and polarized p+A collisions, an important measurement is the yield and momentum distribution of direct photons. Unaffected by the strong force, direct photons traverse the dense medium in the collision zone mostly unchanged, thereby providing information about the initial stages of the collision. However, there is a huge background of photons from other sources, primarily π0 which decay into two photons. The opening angle between the decay photons becomes smaller with higher energies of the original π0. For energies greater than ~20 GeV, the Muon Piston Calorimeter (MPC) cannot distinguish the two decay photons from a single photon, as their showers merge. The MPC-EX, an 8-layer tungsten and silicon sensor sandwich in front of the MPC, can measure and image the shower development, and help distinguish between direct photons and π0 decay photons up to higher energies than the MPC alone. We will describe the MPC-EX detector and its readout, and present the calibration procedures applied to the data in order to obtain the π0 spectrum. This project was supported in part by the U.S. Department of Energy, Office of Science, Office of Workforce Development for Teachers and Scientists (WDTS) under the Science Undergraduate Laboratory Internships Program (SULI).

  12. Development of a semi-adiabatic isoperibol solution calorimeter

    SciTech Connect

    Venkata Krishnan, R.; Jogeswararao, G.; Parthasarathy, R.; Premalatha, S.; Prabhakar Rao, J.; Gunasekaran, G.; Ananthasivan, K.

    2014-12-15

    A semi-adiabatic isoperibol solution calorimeter has been indigenously developed. The measurement system comprises modules for sensitive temperature measurement probe, signal processing, data collection, and joule calibration. The sensitivity of the temperature measurement module was enhanced by using a sensitive thermistor coupled with a lock-in amplifier based signal processor. A microcontroller coordinates the operation and control of these modules. The latter in turn is controlled through personal computer (PC) based custom made software developed with LabView. An innovative summing amplifier concept was used to cancel out the base resistance of the thermistor. The latter was placed in the dewar. The temperature calibration was carried out with a standard platinum resistance (PT100) sensor coupled with an 8½ digit multimeter. The water equivalent of this calorimeter was determined by using electrical calibration with the joule calibrator. The experimentally measured values of the quantum of heat were validated by measuring heats of dissolution of pure KCl (for endotherm) and tris (hydroxyl methyl) amino-methane (for exotherm). The uncertainity in the measurements was found to be within ±3%.

  13. Development of a semi-adiabatic isoperibol solution calorimeter.

    PubMed

    Venkata Krishnan, R; Jogeswararao, G; Parthasarathy, R; Premalatha, S; Prabhakar Rao, J; Gunasekaran, G; Ananthasivan, K

    2014-12-01

    A semi-adiabatic isoperibol solution calorimeter has been indigenously developed. The measurement system comprises modules for sensitive temperature measurement probe, signal processing, data collection, and joule calibration. The sensitivity of the temperature measurement module was enhanced by using a sensitive thermistor coupled with a lock-in amplifier based signal processor. A microcontroller coordinates the operation and control of these modules. The latter in turn is controlled through personal computer (PC) based custom made software developed with LabView. An innovative summing amplifier concept was used to cancel out the base resistance of the thermistor. The latter was placed in the dewar. The temperature calibration was carried out with a standard platinum resistance (PT100) sensor coupled with an 8½ digit multimeter. The water equivalent of this calorimeter was determined by using electrical calibration with the joule calibrator. The experimentally measured values of the quantum of heat were validated by measuring heats of dissolution of pure KCl (for endotherm) and tris (hydroxyl methyl) amino-methane (for exotherm). The uncertainity in the measurements was found to be within ±3%.

  14. Development of a semi-adiabatic isoperibol solution calorimeter

    NASA Astrophysics Data System (ADS)

    Venkata Krishnan, R.; Jogeswararao, G.; Parthasarathy, R.; Premalatha, S.; Prabhakar Rao, J.; Gunasekaran, G.; Ananthasivan, K.

    2014-12-01

    A semi-adiabatic isoperibol solution calorimeter has been indigenously developed. The measurement system comprises modules for sensitive temperature measurement probe, signal processing, data collection, and joule calibration. The sensitivity of the temperature measurement module was enhanced by using a sensitive thermistor coupled with a lock-in amplifier based signal processor. A microcontroller coordinates the operation and control of these modules. The latter in turn is controlled through personal computer (PC) based custom made software developed with LabView. An innovative summing amplifier concept was used to cancel out the base resistance of the thermistor. The latter was placed in the dewar. The temperature calibration was carried out with a standard platinum resistance (PT100) sensor coupled with an 8½ digit multimeter. The water equivalent of this calorimeter was determined by using electrical calibration with the joule calibrator. The experimentally measured values of the quantum of heat were validated by measuring heats of dissolution of pure KCl (for endotherm) and tris (hydroxyl methyl) amino-methane (for exotherm). The uncertainity in the measurements was found to be within ±3%.

  15. Acceleration Studies

    NASA Technical Reports Server (NTRS)

    Rogers, Melissa J. B.

    1993-01-01

    Work to support the NASA MSFC Acceleration Characterization and Analysis Project (ACAP) was performed. Four tasks (analysis development, analysis research, analysis documentation, and acceleration analysis) were addressed by parallel projects. Work concentrated on preparation for and implementation of near real-time SAMS data analysis during the USMP-1 mission. User support documents and case specific software documentation and tutorials were developed. Information and results were presented to microgravity users. ACAP computer facilities need to be fully implemented and networked, data resources must be cataloged and accessible, future microgravity missions must be coordinated, and continued Orbiter characterization is necessary.

  16. Electromagnetic calorimeter for the Heavy Photon Search Experiment at Jefferson Lab

    SciTech Connect

    Buchanan, Emma

    2014-11-01

    The Heavy Photon Search Experiment (HPS) seeks to detect a hypothesised hidden sector boson, the A', predicted to be produced in dark matter decay or annihilation. Theories suggest that the A' couples weakly to electric charge through kinetic mixing, allowing it, as a result, to decay to Standard Matter (SM) lepton pair, which may explain the electron and positron excess recently observed in cosmic rays. Measuring the lepton pair decay of the A' could lead to indirect detection of dark matter. The HPS experiment is a fixed target experiment that will utilize the electron beam produced at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The detector set-up includes a silicon vertex tracker (SVT) and an Electromagnetic Calorimeter (ECal). The ECal will provide the trigger and detect e+e- pairs and its construction and testing forms the focus of this thesis. The ECal consists of 442 PbWO4- tapered crystals with a length 16cm and a 1.6x1.6cm2 cross-section, stacked into a rectangular array and are coupled to Large Area APDs and corresponding pre-amplifiers. Supplementary to the ECal is a Light Monitoring System (LMS) consisting of bi-coloured LEDs that will monitor changes in APD gain and crystal transparency due to radiation damage. Before construction of the ECal each of the components were required to be individually tested to determine a number of different characteristics. Irradiation tests were performed on PbWO4 ECal crystals and, as a comparison, one grown by a different manufacturer to determine their radiation hardness. A technique for annealing the radiation damage by optical bleaching, which involves injecting light of various wavelengths into the crystal, was tested using the blue LED from the LMS as a potential candidate. The light yield dependence on temperature was also measured for one of the PbWO4 crystal types. Each APD was individually tested to determine if they functioned correctly and

  17. Particle acceleration

    NASA Technical Reports Server (NTRS)

    Vlahos, L.; Machado, M. E.; Ramaty, R.; Murphy, R. J.; Alissandrakis, C.; Bai, T.; Batchelor, D.; Benz, A. O.; Chupp, E.; Ellison, D.

    1986-01-01

    Data is compiled from Solar Maximum Mission and Hinothori satellites, particle detectors in several satellites, ground based instruments, and balloon flights in order to answer fundamental questions relating to: (1) the requirements for the coronal magnetic field structure in the vicinity of the energization source; (2) the height (above the photosphere) of the energization source; (3) the time of energization; (4) transistion between coronal heating and flares; (5) evidence for purely thermal, purely nonthermal and hybrid type flares; (6) the time characteristics of the energization source; (7) whether every flare accelerates protons; (8) the location of the interaction site of the ions and relativistic electrons; (9) the energy spectra for ions and relativistic electrons; (10) the relationship between particles at the Sun and interplanetary space; (11) evidence for more than one acceleration mechanism; (12) whether there is single mechanism that will accelerate particles to all energies and also heat the plasma; and (13) how fast the existing mechanisms accelerate electrons up to several MeV and ions to 1 GeV.

  18. Plasma accelerator

    DOEpatents

    Wang, Zhehui; Barnes, Cris W.

    2002-01-01

    There has been invented an apparatus for acceleration of a plasma having coaxially positioned, constant diameter, cylindrical electrodes which are modified to converge (for a positive polarity inner electrode and a negatively charged outer electrode) at the plasma output end of the annulus between the electrodes to achieve improved particle flux per unit of power.

  19. Accelerated Achievement

    ERIC Educational Resources Information Center

    Ford, William J.

    2010-01-01

    This article focuses on the accelerated associate degree program at Ivy Tech Community College (Indiana) in which low-income students will receive an associate degree in one year. The three-year pilot program is funded by a $2.3 million grant from the Lumina Foundation for Education in Indianapolis and a $270,000 grant from the Indiana Commission…

  20. ACCELERATION INTEGRATOR

    DOEpatents

    Pope, K.E.

    1958-01-01

    This patent relates to an improved acceleration integrator and more particularly to apparatus of this nature which is gyrostabilized. The device may be used to sense the attainment by an airborne vehicle of a predetermined velocitv or distance along a given vector path. In its broad aspects, the acceleration integrator utilizes a magnetized element rotatable driven by a synchronous motor and having a cylin drical flux gap and a restrained eddy- current drag cap deposed to move into the gap. The angular velocity imparted to the rotatable cap shaft is transmitted in a positive manner to the magnetized element through a servo feedback loop. The resultant angular velocity of tae cap is proportional to the acceleration of the housing in this manner and means may be used to measure the velocity and operate switches at a pre-set magnitude. To make the above-described dcvice sensitive to acceleration in only one direction the magnetized element forms the spinning inertia element of a free gyroscope, and the outer housing functions as a gimbal of a gyroscope.

  1. Accelerator on a Chip: How It Works

    SciTech Connect

    2014-06-30

    In an advance that could dramatically shrink particle accelerators for science and medicine, researchers used a laser to accelerate electrons at a rate 10 times higher than conventional technology in a nanostructured glass chip smaller than a grain of rice.

  2. Biological Manipulation of Migration Rate: The Use of Advanced Photoperiod to Accelerate Smoltification in Yearling Chinook Salmon, Annual Report of Research 1990.

    SciTech Connect

    Muir, William D.

    1992-06-01

    Research was conducted during 1990 to assess the feasibility of biologically manipulating physiological development and migratory behavior of yearling spring chinook salmon, Oncorhynchus tshawytscha. At Dworshak National Fish Hatchery, one treatment group was exposed to a 3-month advanced photoperiod schedule for 13 weeks preceding release to accelerate smolt development. Another group was exposed to the same advanced photoperiod schedule, but additionally was reared at an elevated water temperature (11.9{degrees}C) for 10 days prior to release. At Leavenworth National Fish Hatchery, a treatment group was exposed to a 3-month advanced photoperiod schedule for 17 weeks. Gill Na{sup +}-K{sup +}ATPase development and migratory performance were described for all groups. The treated fish which were the most physiologically advanced at release were detected in the highest proportions at collector dams and also migrated fastest downstream--similar to results obtained in 1988 and 1989.

  3. Thomas Edison Accelerated Elementary School.

    ERIC Educational Resources Information Center

    Levin, Henry M.; Chasin, Gene

    This paper describes early outcomes of a Sacramento, California, elementary school that participated in the Accelerated Schools Project. The school, which serves many minority and poor students, began training for the project in 1992. Accelerated Schools were designed to advance the learning rate of students through a gifted and talented approach,…

  4. Room-temperature calorimeter for x-ray free-electron lasers

    SciTech Connect

    Tanaka, T. Kato, M.; Saito, N.; Tono, K.; Yabashi, M.; Ishikawa, T.

    2015-09-15

    We have developed a room-temperature calorimeter for absolute radiant power measurements of x-ray free-electron lasers. This room-temperature calorimeter is an electrical substitution device based on the equivalence of electrical and radiant heating. Consequently, the measured radiant powers are traceable to electrical standards, i.e., the International System Units (SI). We demonstrated the performance of the room-temperature calorimeter by electrical power measurements (offline tests). In the offline tests, the room-temperature calorimeter was proven to be able to measure external powers up to at least 6.9 mW, which exceeds the upper limit (∼4 mW) of a cryogenic radiometer (the primary standard detector in Japan). In addition, measurement uncertainties of the room-temperature calorimeter were evaluated to be less than 1.0%, which is adequate for the radiant power measurements of x-ray free-electron lasers. An indirect comparison with the cryogenic radiometer was performed using a synchrotron radiation source to confirm the validity of the absolute radiant powers measured with the room-temperature calorimeter. The absolute radiant powers measured by the calorimeter agreed with those measured by the cryogenic radiometer within 0.6%, which is less than the relative standard uncertainty of the comparison (1.0%)

  5. Room-temperature calorimeter for x-ray free-electron lasers.

    PubMed

    Tanaka, T; Kato, M; Saito, N; Tono, K; Yabashi, M; Ishikawa, T

    2015-09-01

    We have developed a room-temperature calorimeter for absolute radiant power measurements of x-ray free-electron lasers. This room-temperature calorimeter is an electrical substitution device based on the equivalence of electrical and radiant heating. Consequently, the measured radiant powers are traceable to electrical standards, i.e., the International System Units (SI). We demonstrated the performance of the room-temperature calorimeter by electrical power measurements (offline tests). In the offline tests, the room-temperature calorimeter was proven to be able to measure external powers up to at least 6.9 mW, which exceeds the upper limit (∼4 mW) of a cryogenic radiometer (the primary standard detector in Japan). In addition, measurement uncertainties of the room-temperature calorimeter were evaluated to be less than 1.0%, which is adequate for the radiant power measurements of x-ray free-electron lasers. An indirect comparison with the cryogenic radiometer was performed using a synchrotron radiation source to confirm the validity of the absolute radiant powers measured with the room-temperature calorimeter. The absolute radiant powers measured by the calorimeter agreed with those measured by the cryogenic radiometer within 0.6%, which is less than the relative standard uncertainty of the comparison (1.0%).

  6. Room-temperature calorimeter for x-ray free-electron lasers

    NASA Astrophysics Data System (ADS)

    Tanaka, T.; Kato, M.; Saito, N.; Tono, K.; Yabashi, M.; Ishikawa, T.

    2015-09-01

    We have developed a room-temperature calorimeter for absolute radiant power measurements of x-ray free-electron lasers. This room-temperature calorimeter is an electrical substitution device based on the equivalence of electrical and radiant heating. Consequently, the measured radiant powers are traceable to electrical standards, i.e., the International System Units (SI). We demonstrated the performance of the room-temperature calorimeter by electrical power measurements (offline tests). In the offline tests, the room-temperature calorimeter was proven to be able to measure external powers up to at least 6.9 mW, which exceeds the upper limit (˜4 mW) of a cryogenic radiometer (the primary standard detector in Japan). In addition, measurement uncertainties of the room-temperature calorimeter were evaluated to be less than 1.0%, which is adequate for the radiant power measurements of x-ray free-electron lasers. An indirect comparison with the cryogenic radiometer was performed using a synchrotron radiation source to confirm the validity of the absolute radiant powers measured with the room-temperature calorimeter. The absolute radiant powers measured by the calorimeter agreed with those measured by the cryogenic radiometer within 0.6%, which is less than the relative standard uncertainty of the comparison (1.0%).

  7. Particle Accelerators in China

    NASA Astrophysics Data System (ADS)

    Zhang, Chuang; Fang, Shouxian

    As the special machines that can accelerate charged particle beams to high energy by using electromagnetic fields, particle accelerators have been widely applied in scientific research and various areas of society. The development of particle accelerators in China started in the early 1950s. After a brief review of the history of accelerators, this article describes in the following sections: particle colliders, heavy-ion accelerators, high-intensity proton accelerators, accelerator-based light sources, pulsed power accelerators, small scale accelerators, accelerators for applications, accelerator technology development and advanced accelerator concepts. The prospects of particle accelerators in China are also presented.

  8. Perturbations for transient acceleration

    SciTech Connect

    Vargas, Cristofher Zuñiga; Zimdahl, Winfried; Hipólito-Ricaldi, Wiliam S. E-mail: hipolito@ceunes.ufes.br

    2012-04-01

    According to the standard ΛCDM model, the accelerated expansion of the Universe will go on forever. Motivated by recent observational results, we explore the possibility of a finite phase of acceleration which asymptotically approaches another period of decelerated expansion. Extending an earlier study on a corresponding homogeneous and isotropic dynamics, in which interactions between dark matter and dark energy are crucial, the present paper also investigates the dynamics of the matter perturbations both on the Newtonian and General Relativistic (GR) levels and quantifies the potential relevance of perturbations of the dark-energy component. In the background, the model is tested against the Supernova type Ia (SNIa) data of the Constitution set and on the perturbative level against growth rate data, among them those of the WiggleZ survey, and the data of the 2dFGRS project. Our results indicate that a transient phase of accelerated expansion is not excluded by current observations.

  9. Fabrication and Characterization of a Multichannel 3D Thermopile for Chip Calorimeter Applications

    PubMed Central

    Huynh, Tho Phuoc; Zhang, Yilei; Yehuda, Cohen

    2015-01-01

    Thermal sensors based on thermopiles are some of the most robust and popular temperature sensing technologies across industries and research disciplines. A chip calorimeter with a 3D thermopile layout with a large sensing area and multichannel capacity has been developed, which is highly desired for many applications requiring large reaction chambers or high throughputs, such as biofilm research, drug screening, etc. The performance of the device, including temperature sensitivity and heat power sensitivity, was evaluated. The capability to split the chip calorimeter to multiple channels was also demonstrated, which makes the chip calorimeter very flexible and powerful in many applications. PMID:25654716

  10. The small-angle performance of a dual-readout fiber calorimeter

    NASA Astrophysics Data System (ADS)

    Cardini, A.; Cascella, M.; Choi, S.; De Pedis, D.; Ferrari, R.; Franchino, S.; Gaudio, G.; Ha, S.; Hauptman, J.; La Rotonda, L.; Lee, S.; Li, F.; Livan, M.; Meoni, E.; Scuri, F.; Sill, A.; Wigmans, R.

    2016-02-01

    The performance of the RD52 dual-readout calorimeter is measured for very small angles of incidence between the 20 GeV electron beam particles and the direction of the fibers that form the active elements of this calorimeter. The calorimeter response is observed to be independent of the angle of incidence for both the scintillating and the Čerenkov fibers, whereas significant differences are found between the angular dependence of the energy resolution measured with these two types of fibers. The experimental results are on crucial points at variance with the predictions of GEANT4 Monte Carlo simulations.

  11. Central Calorimeter configuration: A study report to the SDC Technical Board

    SciTech Connect

    Kirk, T.B.W.; Wicklund, A.B.

    1991-04-11

    The single most important determinant of the overall Central Calorimeter (CC) shape is the criterion for depth of hadron shower containment. This criterion and its rapidity dependence is discussed in a companion document to this report titled ``Depth Requirements in SSC Calorimeters`` by a D. Green et al., SDC-91-00016. The conclusion reached there is that the calorimeter should be 10 {lambda} thick at {eta} = 0 and increase smoothly to 12 {lambda} at {eta} = 3. We adopt this criterion in this report and discuss the mechanical properties and design details of a CC that meets this condition.

  12. The design and performance of the electromagnetic calorimeters in Hall C at Jefferson Lab

    SciTech Connect

    Vardan Tadevosyan, Hamlet Mkrtchyan, Arshak Asaturyan, Arthur Mkrtchyan, Simon Zhamkochyan

    2012-12-01

    The design and performance of the electromagnetic calorimeters in the magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers, construction information and comparisons of simulated and experimental results are presented. The design and simulated performance for a new calorimeter to be used in the new SHMS spectrometer is also presented. We have developed and constructed electromagnetic calorimeters from TF-1 type lead-glass blocks for the HMS and SOS magnetic spectrometers at JLab Hall C. The HMS/SOS calorimeters are of identical design and construction except for their total size. Blocks of dimension 10 cm × 10 cm × 70 cm are arranged in four planes and stacked 13 and 11 blocks high in the HMS and SOS respectively. The energy resolution of these calorimeters is better than 6%/√E, and pion/electron (π/e) separation of about 100:1 has been achieved in energy range 1–5 GeV. Good agreement has been observed between the experimental and GEANT4 simulated energy resolutions. The HMS/SOS calorimeters have been used nearly in all Hall C experiments, providing good energy resolution and a high pion suppression factor. No significant deterioration in their performance has been observed in the course of use since 1994. For the SHMS spectrometer, presently under construction, details on the calorimeter design and accompanying GEANT4 simulation efforts are given. A Preshower+Shower design was selected as the most cost-effective among several design choices. The preshower will consist of a layer of 28 modules with TF-1 type lead glass radiators, stacked in two columns. The shower part will consist of 224 modules with F-101 type lead glass radiators, stacked in a “fly's eye” configuration of 14 columns and 16 rows. The active area of 120 × 130 cm(2) will encompass the beam envelope at the calorimeter. The anticipated performance of the new calorimeter is simulated over the full momentum range of the SHMS, predicting

  13. Compact accelerator

    DOEpatents

    Caporaso, George J.; Sampayan, Stephen E.; Kirbie, Hugh C.

    2007-02-06

    A compact linear accelerator having at least one strip-shaped Blumlein module which guides a propagating wavefront between first and second ends and controls the output pulse at the second end. Each Blumlein module has first, second, and third planar conductor strips, with a first dielectric strip between the first and second conductor strips, and a second dielectric strip between the second and third conductor strips. Additionally, the compact linear accelerator includes a high voltage power supply connected to charge the second conductor strip to a high potential, and a switch for switching the high potential in the second conductor strip to at least one of the first and third conductor strips so as to initiate a propagating reverse polarity wavefront(s) in the corresponding dielectric strip(s).

  14. The upgrade of the CMS hadron calorimeter with silicon photomultipliers

    NASA Astrophysics Data System (ADS)

    Strobbe, N.

    2017-01-01

    The upgrade of the hadron calorimeter of the CMS experiment at the CERN Large Hadron Collider is currently underway. The endcap sections will be upgraded in the winter of 2016–2017 and the barrel sections during the second LHC long shutdown in 2019. The existing photosensors will be replaced with about 16 000 new silicon photomultipliers (SiPMs), resulting in the first large installation of SiPMs in a radiation environment. All associated front-end electronics will also be upgraded. This paper discusses the motivation for the upgrade and provides a description of the new system, including the SiPMs with associated control electronics and the front-end readout cards.

  15. The LYSO crystal calorimeter for the Mu2e experiment

    NASA Astrophysics Data System (ADS)

    Pezzullo, G.; Budagov, J.; Carosi, R.; Cervelli, F.; Cheng, C.; Cordelli, M.; Corradi, G.; Davydov, Yu; Echenard, B.; Giovannella, S.; Glagolev, V.; Happacher, F.; Hitlin, D.; Luca, A.; Martini, M.; Miscetti, S.; Murat, P.; Ongmonkolkul, P.; Porter, F.; Saputi, A.; Sarra, I.; Spinella, F.; Stomaci, V.; Tassielli, G.

    2014-03-01

    The Mu2e experiment at Fermilab searches the neutrino-less conversion of the muon into electron in the field of an Aluminum nucleus. If such a process will be observed, it will be a proof of the charged-lepton-flavor-violation (cLFV), otherwise Mu2e will set an upper limit of Rμe < 6 × 10-17 @ 90% C.L. (which represents an improvement by 3-4 order of magnitude over the existing limit). The Mu2e detector apparatus consists of a magnetic spectrometer, devoted to the measurement of the electrons momentum, and an electromagnetic calorimeter (EMC) which provides an independent measurement of the electron energy, time and position, used for validating or rejecting candidate tracks selected by the tracking system. In this paper, we describe the baseline project of the EMC and present results in terms of performances and R&D.

  16. A hadronic calorimeter with Glass RPC as sensitive medium

    NASA Astrophysics Data System (ADS)

    Grenier, G.

    2014-09-01

    The SDHCAL technological prototype is a 1 × 1 × 1.3 m3 high-granularity Semi-Digital Hadronic CALorimeter using Glass Resistive Plate Chambers as sensitive medium. It is one of the two HCAL options considered by the ILD Collaboration to be proposed for the detector of the future International Linear Collider project. The prototype is made of up to 50 GRPC detectors of 1 m2 size and 3 mm thickness each with an embedded semi-digital electronics readout that is autotriggering and power-pulsed. The GRPC readout is finely segmented into pads of 1 cm2. Measured performances of the GRPC and the full SDHCAL prototype in terms of homogeneity, low noise and energy resolution are presented in this proceeding.

  17. A superconducting supercollider calorimeter photomultiplier tube preamplifier circuit

    NASA Astrophysics Data System (ADS)

    Panescu, Dorin; Lackey, Joe; Robl, Phil; Smith, Wesley H.

    1992-07-01

    This study presents the design of the front end amplifier for a scintillator calorimeter with photomultiplier tube (PMT) readout. The design is based on analytical computations and SPICE simulations, and is checked against tests performed on a prototyped circuit. We were looking to achieve 1) a very low droop within the 4 ns after the integration of the photomultiplier tube (PMT) signal was completed, 2) a very low noise figure for the whole amplifier in a 100 MHz bandwidth, 3) an input impedance optimized for the PMT which is actually used, 4) baseline restoration as quick as possible at the output of the clip amps. 5) no loss of information due to the saturation at intermediary stages (e.g. integrator), and 6) an output driving 100 Ω twisted pair cables, or 50 Ω coaxial cables, in order to transmit the signal to switched capacitor arrays for analog storage.

  18. Performance of the ATLAS electromagnetic calorimeter barrel module 0

    NASA Astrophysics Data System (ADS)

    Aubert, B.; Ballansat, J.; Bazan, A.; Beaugiraud, B.; Boniface, J.; Chollet, F.; Colas, J.; Delebecque, P.; di Ciaccio, L.; Dumont-Dayot, N.; El Kacimi, M.; Gaumer, O.; Ghez, P.; Girard, C.; Gouanère, M.; Kambara, H.; Jérémie, A.; Jézéquel, S.; Lafaye, R.; Leflour, T.; Le Maner, C.; Lesueur, J.; Massol, N.; Moynot, M.; Neukermans, L.; Perrodo, P.; Perrot, G.; Poggioli, L.; Prast, J.; Przysiezniak, H.; Riccadona, X.; Sauvage, G.; Thion, J.; Wingerter-Seez, I.; Zitoun, R.; Zolnierowski, Y.; Chen, H.; Citterio, M.; Farrell, J.; Gordon, H.; Hackenburg, B.; Hoffman, A.; Kierstead, J.; Lanni, F.; Leite, M.; Lissauer, D.; Ma, H.; Makowiecki, D.; Radeka, V.; Rahm, D.; Rajagopalan, S.; Rescia, S.; Stumer, I.; Takai, H.; Yip, K.; Benchekroun, D.; Driouichi, C.; Hoummada, A.; Hakimi, M.; Stroynowski, R.; Ye, J.; Beck Hansen, J.; Belymam, A.; Bremer, J.; Chevalley, J. L.; Fassnacht, P.; Gianotti, F.; Hervas, L.; Marin, C. P.; Pailler, P.; Schilly, P.; Seidl, W.; Vossebeld, J.; Vuillemin, V.; Clark, A.; Efthymiopoulos, I.; Moneta, L.; Belhorma, B.; Collot, J.; de Saintignon, P.; Dzahini, D.; Ferrari, A.; Gallin-Martel, M. L.; Hostachy, J. Y.; Martin, P.; Muraz, J. F.; Ohlsson-Malek, F.; Saboumazrag, S.; Ban, J.; Cartiglia, N.; Cunitz, H.; Dodd, J.; Gara, A.; Leltchouk, M.; Negroni, S.; Parsons, J. A.; Seman, M.; Simion, S.; Sippach, W.; Willis, W.; Barreiro, F.; Garcia, G.; Labarga, L.; Rodier, S.; Del Peso, J.; Alexa, C.; Barrillon, P.; Benchouk, C.; Chekhtman, A.; Dinkespiler, B.; Djama, F.; Duval, P. Y.; Henry-Couannier, F.; Hinz, L.; Jevaud, M.; Karst, P.; Le van Suu, A.; Martin, L.; Martin, O.; Mirea, A.; Monnier, E.; Nagy, E.; Nicod, D.; Olivier, C.; Pralavorio, P.; Repetti, B.; Raymond, M.; Sauvage, D.; Tisserant, S.; Toth, J.; Wielers, M.; Battistoni, G.; Bonivento, W.; Carminati, L.; Cavalli, D.; Costa, G.; Delmastro, M.; Fanti, M.; Mandelli, L.; Mazzanti, M.; Perini, L.; Resconi, S.; Tartarelli, G. F.; Aulchenko, V.; Kazanin, V.; Kolachev, G.; Malyshev, V.; Maslennikov, A.; Pospelov, G.; Snopkov, R.; Shousharo, A.; Talyshev, A.; Tikhonov, Yu.; Augé, E.; Bourdarios, C.; Breton, D.; Cros, P.; de La Taille, C.; Falleau, I.; Fournier, D.; Guilhem, G.; Hassani, S.; Jacquier, Y.; Kordas, K.; Macé, G.; Merkel, B.; Noppe, J. M.; Parrour, G.; Pétroff, P.; Puzo, P.; Richer, J. P.; Rousseau, D.; Seguin-Moreau, N.; Serin, L.; Tocut, V.; Veillet, J. J.; Zerwas, D.; Astesan, F.; Bertoli, W.; Camard, A.; Canton, B.; Fichet, S.; Hubaut, F.; Imbault, D.; Lacour, D.; Laforge, B.; Le Dortz, O.; Martin, D.; Nikolic-Audit, I.; Orsini, F.; Rossel, F.; Schwemling, P.; Cleland, W.; McDonald, J.; Abouelouafa, E. M.; Ben Mansour, A.; Cherkaoui, R.; El Mouahhidi, Y.; Ghazlane, H.; Idrissi, A.; Belorgey, J.; Bernard, R.; Chalifour, M.; Le Coroller, A.; Ernwein, J.; Mansoulié, B.; Renardy, J. F.; Schwindling, J.; Taguet, J.-P.; Teiger, J.; Clément, C.; Lund-Jensen, B.; Lundqvist, J.; Megner, L.; Pearce, M.; Rydstrom, S.; Egdemir, J.; Engelmann, R.; Hoffman, J.; McCarthy, R.; Rijssenbeek, M.; Steffens, J.; Atlas Electromagnetic Liquid Argon Calorimeter Group

    2003-03-01

    The construction and performance of the barrel pre-series module 0 of the future ATLAS electromagnetic calorimeter at the LHC is described. The signal reconstruction and performance of ATLAS-like electronics has been studied. The signal to noise ratio for muons has been found to be 7.11±0.07. An energy resolution of better than 9.5% GeV1/2/ E (sampling term) has been obtained with electron beams of up to 245 GeV. The uniformity of the response to electrons in an area of Δ η×Δ φ=1.2×0.075 has been measured to be better than 0.8%.

  19. Calibration of BGO Calorimeter of the DAMPE in Space

    NASA Astrophysics Data System (ADS)

    Wang, Chi

    2016-07-01

    The Dark Matter Particle Explore (DAMPE) is a satellite based experiment which launched on December 2015 and aims at indirect searching for dark matter by measuring the spectra of high energy e±, γ from 5GeV up to 10TeV originating from deep space. The 3D imaging BGO calorimeter of DAMPE was designed to precisely measurement the primary energy of the electromagnetic particle and provides a highly efficient rejection of the hadronic background by reconstruct the longitudinal and lateral profiles of showers. To achieve the expected accuracy on the energy measurement, each signal channel has to be calibrated. The energy equalization is performed using the signal that Minimum Ionizing Particles (MIP) leave in each BGO bar, the MIPs measurement method with orbit data and, data quality, time stability using MIPs data will be presented, too.

  20. Progress report for the scintillator plate calorimeter subsystem

    SciTech Connect

    Not Available

    1990-12-31

    This report covers the work completed in FY90 by ANL staff and those of Westinghouse STC and BICRON Corporation under subcontract to ANL towards the design of a compensating calorimeter based on the use of scintillator plate as the sensitive medium. It is presented as five task sections dealing with respectively mechanical design; simulation studies; optical system design; electronics development; development of rad hard plastic scintillator and wavelength shifter and a summary. The work carried out by the University of Tennessee under a subcontract from ANL is reported separately. Finally, as principal institution with responsibility for the overall management of this subsystem effort, the summary here reports the conclusions resulting from the work of the collaboration and their impact on our proposed direction of effort in FY91. This proposal, for obvious reasons is given separately.

  1. Can a PB / SCIFI Calorimeter Survive the SSC?

    SciTech Connect

    D. W. Hertzog; S. A. Hughes; P. E. Reimer; R. L. Tayloe; K. F. Johnson; S. Majewski; C. Zorn; M. Zorn

    1990-03-01

    A scintillating fiber based electromagnetic calorimeter module built from radiation-hard materials has been tested in a beam capable of delivering both low and high currents of monoenergetic electrons. Energy resolution and light output measurements were made following high-dose exposures. The procedure was repeated until the resolution of the detector decreased from an initial value of 6.9%/sqrt E to 14.0%/sqrt E and the pulse height dropped by a factor of 11. After four weeks, the detector was retested. Partial recovery was observed in the light output which returned to approximately 52% of its original value. The resolution recovered to a value of 8.8%/sqrt E. The tests are described.

  2. Can a Pb/SCIFI calorimeter survive the SSC

    SciTech Connect

    Hertzog, D.W.; Hughes, S.A.; Reimer, P.E.; Tayloe, R.L. ); Johnson, K.F. ); Majewski, S.; Zorn, C.; Zorn, M. )

    1990-01-01

    A scintillating fiber based electromagnetic calorimeter module built from radiation-hard materials has been tested in a beam capable of delivering both low and high currents of monoenergetic electrons. Energy resolution and light output measurements were made following high-dose exposures. The procedure was repeated until the resolution of the detector decreased from an initial value of 6.9%{radical}E to 14.0%{radical}E and the pulse height dropped by a factor of 11. After four weeks, the detector was retested. Partial recovery was observed in the light output which returned to approximately 52% of its original value. The resolution recovered to a value of 8.8%{radical}E. The tests are described. 9 refs., 4 figs.

  3. The CMS Hadron Forward Calorimeter Upgrade During Phase I

    NASA Astrophysics Data System (ADS)

    Gülmez, E.

    2014-06-01

    The CMS Hadron Forward Calorimeter is being upgraded during phase 1. The upgrade includes the replacement of the current PMTs with the 4-anode ones and the readout electronics. Stray muons hitting the PMT windows produce Cherenkov light causing erroneous signals. These signals are detrimental to the triggering and physic results, since such signals mimic very high energy events. The new 4-anode PMTs are selected because of their thin windows to reduce the Cherenkov light production. Additional anodes also provide information to eliminate such signals. These new PMTs have been tested extensively to understand their characteristics and to develop the algorithms to eliminate the unwanted signals. Eventually, the current read out will be replaced with two-channel readout electronics for each PMT. The overall expected improvement on the physics results will also be discussed.

  4. The upgrade of the Belle II forward calorimeter

    NASA Astrophysics Data System (ADS)

    Manoni, E.; Aloisio, A.; Baccaro, S.; Branchini, P.; Cecchi, C.; Cemmi, A.; De Lucia, E.; De Nardo, G.; de Sangro, R.; Felici, G.; Finocchiaro, G.; Fiore, S.; Giordano, R.; Merola, M.; Oberhof, B.; Passeri, A.; Peruzzi, I. M.; Piccolo, M.; Rossi, A.; Sciacca, C.

    2017-02-01

    The new facility SuperKEKB will be an upgrade of the existing KEKB electron-positron asymmetric collider, with a target luminosity of 8 ×1035cm-2s-1, about 40 times greater than that of KEKB. The detector will also be upgraded to cope with the higher luminosity, pile-up and occupancy. We report here on the design and development of the new pure CsI calorimeter for the forward region. An intensive R&D is being carried on to study the performance of pure CsI crystals with Avalanche Photodiodes readout. Results about the relative energy resolution of this detector, along with radiation hardness studies of all the components, are presented. A matrix of 16 crystals has been put on an electron beam at the BTF facility in Frascati and results in terms of energy resolution of this prototype are also discussed.

  5. A high precision calorimeter for the SOX experiment

    NASA Astrophysics Data System (ADS)

    Papp, L.; Agostini, M.; Altenmüller, K.; Appel, S.; Caminata, A.; Cereseto, R.; Di Noto, L.; Farinon, S.; Musenich, R.; Neumair, B.; Oberauer, L.; Pallavicini, M.; Schönert, S.; Testera, G.; Zavatarelli, S.

    2016-07-01

    The SOX (Short distance neutrino Oscillations with BoreXino) experiment is being built to discover or reject eV-scale sterile neutrinos by observing short baseline oscillations of active-to-sterile neutrinos [1]. For this purpose, a 100 kCi 144Ce-144Pr antineutrino generator (CeSOX) will be placed under the BOREXINO detector at the Laboratori Nazionali del Gran Sasso. Thanks to its large size and very low background, BOREXINO is an ideal detector to discover or reject eV-scale sterile neutrinos. To reach the maximal sensitivity, we aim at determining the neutrino flux emitted by the antineutrino generator with a < 1 % accuracy. With this goal, TU München and INFN Genova are developing a vacuum calorimeter, which is designed to measure the source-generated heat with high accuracy.

  6. Geant4 validation with CMS calorimeters test-beam data

    SciTech Connect

    Piperov, Stefan; /Sofiya, Inst. Nucl. Res. /Fermilab

    2008-08-01

    CMS experiment is using Geant4 for Monte-Carlo simulation of the detector setup. Validation of physics processes describing hadronic showers is a major concern in view of getting a proper description of jets and missing energy for signal and background events. This is done by carrying out an extensive studies with test beam using the prototypes or real detector modules of the CMS calorimeter. These data are matched with Geant4 predictions. Tuning of the Geant4 models is carried out and steps to be used in reproducing detector signals are defined in view of measurements of energy response, energy resolution, transverse and longitudinal shower profiles for a variety of hadron beams over a broad energy spectrum between 2 to 300 GeV/c.

  7. Radiation hard programmable delay line for LHCb calorimeter upgrade

    NASA Astrophysics Data System (ADS)

    Mauricio, J.; Gascón, D.; Vilasís, X.; Picatoste, E.; Machefert, F.; Lefrancois, J.; Duarte, O.; Beigbeder, C.

    2014-01-01

    This paper describes the implementation of a SPI-programmable clock delay chip based on a Delay Locked Loop (DLL) in order to shift the phase of the LHC clock (25 ns) in steps of 1ns, with less than 5 ps jitter and 23 ps of DNL. The delay lines will be integrated into ICECAL, the LHCb calorimeter front-end analog signal processing ASIC in the near future. The stringent noise requirements on the ASIC imply minimizing the noise contribution of digital components. This is accomplished by implementing the DLL in differential mode. To achieve the required radiation tolerance several techniques are applied: double guard rings between PMOS and NMOS transistors as well as glitch suppressors and TMR Registers. This 5.7 mm2 chip has been implemented in CMOS 0.35 μm technology.

  8. Monitoring the stability of the CMS electromagnetic calorimeter

    NASA Astrophysics Data System (ADS)

    Ferri, Federico

    2011-04-01

    The lead tungstate electromagnetic calorimeter of the CMS experiment has been proved to achieve an excellent energy resolution during the commissioning phase of the detector. The uniformity of the relative response of individual channels and the energy scale for electrons and photons are constrained by the several calibration procedures. The stability of the detector in time is constantly monitored throughout the LHC operation by means of dedicated runs and data taken at 100 Hz in the 3 μs abort gap at the end of each 89 μs beam cycle. A laser monitoring system is used to track the single channel response variations with time, as changes of the crystal transparency caused by irradiation. The stability of crucial detector parameters such as high voltage, temperature and electronic noise and the performance of the operation of the light monitoring system are shown to fulfill the requirements needed to achieve the target resolution of 0.5% at high energies.

  9. The Electron Calorimeter (ECAL) Long Duration Balloon Experiment

    NASA Technical Reports Server (NTRS)

    Guzik, T. G.; Adams, J. H.; Bashindzhagyan, G.; Binns, W. R.; Chang, J.; Cherry, M. L.; Christl, M.; Dowkontt, P.; Ellison, B.; Isbert, J. B.; Israel, M. H.; Korotkova, N.; Panasyuk, M.; Panov, A.; Sokolskaya, N.; Stewart, M.; Watts, J.; Wefel, P.; Zatsepin, V.

    2007-01-01

    Accurate measurements of the cosmic ray electron energy spectrum in the energy region 50 GeV to greater than 1 TeV may reveal structure caused by the annihilation of exotic dark matter particles and/or individual cosmic ray sources. Here we describe a new long duration balloon (LDB) experiment, ECAL, optimized to directly measure cosmic ray electrons up to several TeV. ECAL includes a double layer silicon matrix, a scintillating optical fiber track imager, a neutron detector and a fully active calorimeter to identify more than 90% of the incident electrons with an energy resolution of about 1.7% while misidentifying only 1 in 200,000 protons and 0.8% of secondary gamma rays as electrons. Two ECAL flights in Antarctica are planned for a total exposure of 50 days with the first flight anticipate for December 2009.

  10. Finite element analysis of the SDC barrel and endcap calorimeters

    SciTech Connect

    Guarino, V.; Hill, N.; Nasiakta, J.

    1992-03-11

    In designing the SCD barrel and endcap calorimeters, the inter-module connecting forces must be known in order to determine the required size and number of connecting links between modules, and in order to understand how individual modules will be affected by these forces when assembled to form a full barrel and endcap. The connecting forces were found by analyzing three-dimensional Finite Element Models of both the barrel and endcap. This paper is divided into two parts, the first part will describe in detail the results of the barrel analysis and the second part will describe the results obtained from the endcap analysis. A similar approach was used in constructing the models for both analysis.

  11. Consequences of removing the flattening filter from linear accelerators in generating high dose rate photon beams for clinical applications: A Monte Carlo study verified by measurement

    NASA Astrophysics Data System (ADS)

    Ishmael Parsai, E.; Pearson, David; Kvale, Thomas

    2007-08-01

    An Elekta SL-25 medical linear accelerator (Elekta Oncology Systems, Crawley, UK) has been modelled using Monte Carlo simulations with the photon flattening filter removed. It is hypothesized that intensity modulated radiation therapy (IMRT) treatments may be carried out after the removal of this component despite it's criticality to standard treatments. Measurements using a scanning water phantom were also performed after the flattening filter had been removed. Both simulated and measured beam profiles showed that dose on the central axis increased, with the Monte Carlo simulations showing an increase by a factor of 2.35 for 6 MV and 4.18 for 10 MV beams. A further consequence of removing the flattening filter was the softening of the photon energy spectrum leading to a steeper reduction in dose at depths greater than the depth of maximum dose. A comparison of the points at the field edge showed that dose was reduced at these points by as much as 5.8% for larger fields. In conclusion, the greater photon fluence is expected to result in shorter treatment times, while the reduction in dose outside of the treatment field is strongly suggestive of more accurate dose delivery to the target.

  12. The Uniformly Accelerated Reference Frame

    ERIC Educational Resources Information Center

    Hamilton, J. Dwayne

    1978-01-01

    The observations that would be made by a uniformly accelerated observer, including the observer's event horizon, the variation of clock rates with position, and the effects of following a freely falling object are considered in detail. (SL)

  13. Accelerated testing of space batteries

    NASA Technical Reports Server (NTRS)

    Mccallum, J.; Thomas, R. E.; Waite, J. H.

    1973-01-01

    An accelerated life test program for space batteries is presented that fully satisfies empirical, statistical, and physical criteria for validity. The program includes thermal and other nonmechanical stress analyses as well as mechanical stress, strain, and rate of strain measurements.

  14. Laser acceleration

    NASA Astrophysics Data System (ADS)

    Tajima, T.; Nakajima, K.; Mourou, G.

    2017-02-01

    The fundamental idea of Laser Wakefield Acceleration (LWFA) is reviewed. An ultrafast intense laser pulse drives coherent wakefield with a relativistic amplitude robustly supported by the plasma. While the large amplitude of wakefields involves collective resonant oscillations of the eigenmode of the entire plasma electrons, the wake phase velocity ˜ c and ultrafastness of the laser pulse introduce the wake stability and rigidity. A large number of worldwide experiments show a rapid progress of this concept realization toward both the high-energy accelerator prospect and broad applications. The strong interest in this has been spurring and stimulating novel laser technologies, including the Chirped Pulse Amplification, the Thin Film Compression, the Coherent Amplification Network, and the Relativistic Mirror Compression. These in turn have created a conglomerate of novel science and technology with LWFA to form a new genre of high field science with many parameters of merit in this field increasing exponentially lately. This science has triggered a number of worldwide research centers and initiatives. Associated physics of ion acceleration, X-ray generation, and astrophysical processes of ultrahigh energy cosmic rays are reviewed. Applications such as X-ray free electron laser, cancer therapy, and radioisotope production etc. are considered. A new avenue of LWFA using nanomaterials is also emerging.

  15. BICEP's acceleration

    SciTech Connect

    Contaldi, Carlo R.

    2014-10-01

    The recent Bicep2 [1] detection of, what is claimed to be primordial B-modes, opens up the possibility of constraining not only the energy scale of inflation but also the detailed acceleration history that occurred during inflation. In turn this can be used to determine the shape of the inflaton potential V(φ) for the first time — if a single, scalar inflaton is assumed to be driving the acceleration. We carry out a Monte Carlo exploration of inflationary trajectories given the current data. Using this method we obtain a posterior distribution of possible acceleration profiles ε(N) as a function of e-fold N and derived posterior distributions of the primordial power spectrum P(k) and potential V(φ). We find that the Bicep2 result, in combination with Planck measurements of total intensity Cosmic Microwave Background (CMB) anisotropies, induces a significant feature in the scalar primordial spectrum at scales k∼ 10{sup -3} Mpc {sup -1}. This is in agreement with a previous detection of a suppression in the scalar power [2].

  16. Dielectric laser accelerators

    NASA Astrophysics Data System (ADS)

    England, R. Joel; Noble, Robert J.; Bane, Karl; Dowell, David H.; Ng, Cho-Kuen; Spencer, James E.; Tantawi, Sami; Wu, Ziran; Byer, Robert L.; Peralta, Edgar; Soong, Ken; Chang, Chia-Ming; Montazeri, Behnam; Wolf, Stephen J.; Cowan, Benjamin; Dawson, Jay; Gai, Wei; Hommelhoff, Peter; Huang, Yen-Chieh; Jing, Chunguang; McGuinness, Christopher; Palmer, Robert B.; Naranjo, Brian; Rosenzweig, James; Travish, Gil; Mizrahi, Amit; Schachter, Levi; Sears, Christopher; Werner, Gregory R.; Yoder, Rodney B.

    2014-10-01

    The use of infrared lasers to power optical-scale lithographically fabricated particle accelerators is a developing area of research that has garnered increasing interest in recent years. The physics and technology of this approach is reviewed, which is referred to as dielectric laser acceleration (DLA). In the DLA scheme operating at typical laser pulse lengths of 0.1 to 1 ps, the laser damage fluences for robust dielectric materials correspond to peak surface electric fields in the GV /m regime. The corresponding accelerating field enhancement represents a potential reduction in active length of the accelerator between 1 and 2 orders of magnitude. Power sources for DLA-based accelerators (lasers) are less costly than microwave sources (klystrons) for equivalent average power levels due to wider availability and private sector investment. Because of the high laser-to-particle coupling efficiency, required pulse energies are consistent with tabletop microJoule class lasers. Combined with the very high (MHz) repetition rates these lasers can provide, the DLA approach appears promising for a variety of applications, including future high-energy physics colliders, compact light sources, and portable medical scanners and radiative therapy machines.

  17. Advanced concepts for acceleration

    SciTech Connect

    Keefe, D.

    1986-07-01

    Selected examples of advanced accelerator concepts are reviewed. Such plasma accelerators as plasma beat wave accelerator, plasma wake field accelerator, and plasma grating accelerator are discussed particularly as examples of concepts for accelerating relativistic electrons or positrons. Also covered are the pulsed electron-beam, pulsed laser accelerator, inverse Cherenkov accelerator, inverse free-electron laser, switched radial-line accelerators, and two-beam accelerator. Advanced concepts for ion acceleration discussed include the electron ring accelerator, excitation of waves on intense electron beams, and two-wave combinations. (LEW)

  18. Accelerators and the Accelerator Community

    SciTech Connect

    Malamud, Ernest; Sessler, Andrew

    2008-06-01

    In this paper, standing back--looking from afar--and adopting a historical perspective, the field of accelerator science is examined. How it grew, what are the forces that made it what it is, where it is now, and what it is likely to be in the future are the subjects explored. Clearly, a great deal of personal opinion is invoked in this process.

  19. Beam test evaluation of electromagnetic calorimeter modules made from proton-damaged PbWO4 crystals

    DOE PAGES

    Adams, T.; Adzic, P.; Ahuja, S.; ...

    2016-04-11

    The performance of electromagnetic calorimeter modules made of proton-irradiated PbWO4 crystals has been studied in beam tests. The modules, similar to those used in the Endcaps of the CMS electromagnetic calorimeter (ECAL), were formed from 5×5 matrices of PbWO4 crystals, which had previously been exposed to 24 GeV protons up to integrated fluences between 2.1 × 1013 and 1.3 × 1014 cm–2. These correspond to the predicted charged-hadron fluences in the ECAL Endcaps at pseudorapidity η = 2.6 after about 500 fb–1 and 3000 fb–1 respectively, corresponding to the end of the LHC and High Luminosity LHC operation periods. Themore » irradiated crystals have a lower light transmission for wavelengths corresponding to the scintillation light, and a correspondingly reduced light output. A comparison with four crystals irradiated in situ in CMS showed no significant rate dependence of hadron-induced damage. A degradation of the energy resolution and a non-linear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The latter is interpreted, through comparison with simulation, as a side-effect of the degradation in light transmission. In conclusion, the experimental results obtained can be used to estimate the long term performance of the CMS ECAL.« less

  20. Beam test evaluation of electromagnetic calorimeter modules made from proton-damaged PbWO4 crystals

    NASA Astrophysics Data System (ADS)

    Adams, T.; Adzic, P.; Ahuja, S.; Anderson, D.; Andrews, M. B.; Antropov, I.; Antunovic, Z.; Arcidiacono, R.; Arenton, M. W.; Argirò, S.; Askew, A.; Attikis, A.; Auffray, E.; Baccaro, S.; Baffioni, S.; Bailleux, D.; Baillon, P.; Barney, D.; Barone, L.; Bartoloni, A.; Bartosik, N.; Becheva, E.; Bein, S.; Silva, C. Beirāo Da Cruz E.; Bell, K. W.; Benaglia, A.; Bendavid, J.; Berry, D.; Besancon, M.; Betev, B.; Bialas, W.; Bianchini, L.; Biino, C.; Bitioukov, S.; Bornheim, A.; Brianza, L.; Brinkerhoff, A.; Brown, R. M.; Brummitt, A.; Busson, P.; Candelise, V.; Carrillo Montoya, C. A.; Cartiglia, N.; Cavallari, F.; Chang, Y. W.; Chen, K. F.; Chevenier, G.; Chipaux, R.; Clement, E.; Cockerill, D. J. A.; Corpe, L.; Couderc, F.; Courbon, B.; Cox, B.; Cucciati, G.; Cussans, D.; D'imperio, G.; Da Silva Di Calafiori, D. R.; Dafinei, I.; Daguin, J.; Daskalakis, G.; Tinoco Mendes, A. D.; De Guio, F.; Degano, A.; Dejardin, M.; Del Re, D.; Della Ricca, G.; Denegri, D.; Depasse, P.; Dev, N.; Deyrail, D.; Di Marco, E.; Diamond, B.; Diemoz, M.; Dissertori, G.; Dittmar, M.; Djambazov, L.; Doan, T. H.; Dobrzynski, L.; Dolgopolov, A.; Donegà, M.; Dordevic, M.; Dröge, M.; Durkin, T.; Dutta, D.; El Mamouni, H.; Elliott-Peisert, A.; Elmalis, E.; Fabbro, B.; Fasanella, G.; Faure, J.; Fay, J.; Fedorov, A.; Ferri, F.; Francis, B.; Frank, N.; Franzoni, G.; Funk, W.; Ganjour, S.; Gascon, S.; Gastal, M.; Geerebaert, Y.; Gelli, S.; Gerosa, R.; Ghezzi, A.; Giakoumopoulou, V. A.; Givernaud, A.; Gninenko, S.; Godinovic, N.; Goeckner-Wald, N.; Golubev, N.; Govoni, P.; Gras, P.; Guilloux, F.; Haller, C.; Hamel de Monchenault, G.; Hansen, M.; Hansen, P.; Hardenbrook, J.; Heath, H. F.; Hill, J.; Hirosky, R.; Hobson, P. R.; Holme, O.; Honma, A.; Hou, W.-S.; Hsiung, Y.; Iiyama, Y.; Ille, B.; Ingram, Q.; Jain, S.; Jarry, P.; Jessop, C.; Jovanovic, D.; Kachanov, V.; Kalafut, S.; Kao, K. Y.; Kellams, N.; Kesisoglou, S.; Khatiwada, A.; Konoplyannikov, A.; Konstantinov, D.; Korzhik, M.; Kovac, M.; Kubota, Y.; Kucher, I.; Kumar, A.; Kumar, A.; Kuo, C.; Kyberd, P.; Kyriakis, A.; Latyshev, G.; Lecoq, P.; Ledovskoy, A.; Lei, Y. J.; Lelas, D.; Lethuillier, M.; Li, H.; Lin, W.; Liu, Y. F.; Locci, E.; Longo, E.; Loukas, D.; Lu, R.-S.; Lucchini, M. T.; Lustermann, W.; Mackay, C. K.; Magniette, F.; Malcles, J.; Malhotra, S.; Mandjavidze, I.; Maravin, Y.; Margaroli, F.; Marinelli, N.; Marini, A. C.; Martelli, A.; Marzocchi, B.; Massironi, A.; Matveev, V.; Mechinsky, V.; Meng, F.; Meridiani, P.; Micheli, F.; Milosevic, J.; Mousa, J.; Musella, P.; Nessi-Tedaldi, F.; Neu, C.; Newman, H.; Nicolaou, C.; Nourbakhsh, S.; Obertino, M. M.; Organtini, G.; Orimoto, T.; Paganini, P.; Paganis, E.; Paganoni, M.; Pandolfi, F.; Panov, V.; Paramatti, R.; Parracho, P.; Pastrone, N.; Paulini, M.; Pauss, F.; Pauwels, K.; Pellegrino, F.; Pena, C.; Perniè, L.; Peruzzi, M.; Petrakou, E.; Petyt, D.; Pigazzini, S.; Piroué, P.; Planer, M.; Plestina, R.; Polic, D.; Prosper, H.; Ptochos, F.; Puljak, I.; Quittnat, M.; Ragazzi, S.; Rahatlou, S.; Rander, J.; Ranjan, K.; Rasteiro Da Silva, J.; Razis, P. A.; Romanteau, T.; Rosowsky, A.; Rovelli, C.; Rusack, R.; Salerno, R.; Santanastasio, F.; Santra, A.; Schönenberger, M.; Seez, C.; Sharma, V.; Shepherd-Themistocleous, C.; Shiu, J. G.; Shivpuri, R. K.; Singovsky, A.; Sinthuprasith, T.; Sirois, Y.; Smiljkovic, N.; Soffi, L.; Sun, M.; Symonds, P.; Tabarelli de Fatis, T.; Tambe, N.; Tarasov, I.; Taroni, S.; Teixeira De Lima, R.; Thea, A.; Theofilatos, K.; Thiant, F.; Titov, M.; Torbet, M.; Trapani, P. P.; Tropea, P.; Tsai, J. f.; Tsirou, A.; Turkewitz, J.; Tyurin, N.; Tzeng, Y. M.; Uzunian, A.; Valls, N.; Varela, J.; Veeraraghavan, V.; Verdini, P. G.; Vichoudis, P.; Vlassov, E.; Wang, J.; Wang, T.; Weinberg, M.; Wolfe, E.; Wood, J.; Zabi, A.; Zahid, S.; Zelepoukine, S.; Zghiche, A.; Zhang, L.; Zhu, K.; Zhu, R.; Zuyeuski, R.

    2016-04-01

    The performance of electromagnetic calorimeter modules made of proton-irradiated PbWO4 crystals has been studied in beam tests. The modules, similar to those used in the Endcaps of the CMS electromagnetic calorimeter (ECAL), were formed from 5×5 matrices of PbWO4 crystals, which had previously been exposed to 24 GeV protons up to integrated fluences between 2.1× 1013 and 1.3× 1014 cm-2. These correspond to the predicted charged-hadron fluences in the ECAL Endcaps at pseudorapidity η = 2.6 after about 500 fb-1 and 3000 fb-1 respectively, corresponding to the end of the LHC and High Luminosity LHC operation periods. The irradiated crystals have a lower light transmission for wavelengths corresponding to the scintillation light, and a correspondingly reduced light output. A comparison with four crystals irradiated in situ in CMS showed no significant rate dependence of hadron-induced damage. A degradation of the energy resolution and a non-linear response to electron showers are observed in damaged crystals. Direct measurements of the light output from the crystals show the amplitude decreasing and pulse becoming faster as the fluence increases. The latter is interpreted, through comparison with simulation, as a side-effect of the degradation in light transmission. The experimental results obtained can be used to estimate the long term performance of the CMS ECAL.

  1. The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1

    NASA Astrophysics Data System (ADS)

    Abdallah, J.; Alexa, C.; Amaral Coutinho, Y.; Amor Dos Santos, S. P.; Anderson, K. J.; Arabidze, G.; Araque, J. P.; Artamonov, A.; Asquith, L.; Astalos, R.; Backus Mayes, J.; Bartos, P.; Batkova, L.; Bertolucci, F.; Bessidskaia Bylund, O.; Blanco Castro, A.; Blazek, T.; Bohm, C.; Boumediene, D.; Boveia, A.; Brown, H.; Busato, E.; Calkins, R.; Calvet, D.; Calvet, S.; Camacho Toro, R.; Caminal Armadans, R.; Carli, T.; Carvalho, J.; Cascella, M.; Castro, N. F.; Cavasinni, V.; Cerqueira, A. S.; Chadelas, R.; Chakraborty, D.; Chekanov, S.; Chen, X.; Chikovani, L.; Choudalakis, G.; Cinca, D.; Ciubancan, M.; Clement, C.; Cole, S.; Constantinescu, S.; Costin, T.; Crouau, M.; Crozatier, C.; Cuciuc, C.-M.; Da Cunha Sargedas De Sousa, M. J.; Darmora, S.; Davidek, T.; Del Prete, T.; Dita, S.; Djobava, T.; Dolejsi, J.; Dotti, A.; Dubreuil, E.; Dunford, M.; Eriksson, D.; Errede, S.; Errede, D.; Faltova, J.; Farbin, A.; Febbraro, R.; Federic, P.; Feng, E. J.; Ferrer, A.; Fiascaris, M.; Fiolhais, M. C. N.; Fiorini, L.; Francavilla, P.; Fullana Torregrosa, E.; Galhardo, B.; Gellerstedt, K.; Ghodbane, N.; Giakoumopoulou, V.; Giangiobbe, V.; Giokaris, N.; Glonti, G. L.; Gomes, A.; Gonzalez Parra, G.; Grenier, P.; Grinstein, S.; Gris, Ph.; Guicheney, C.; Hakobyan, H.; Hard, A. S.; Harkusha, S.; Heelan, L.; Helsens, C.; Henriques Correia, A. M.; Hernández Jiménez, Y.; Hernandez, C. M.; Higón-Rodriguez, E.; Hurwitz, M.; Huseynov, N.; Huston, J.; Jen-La Plante, I.; Jennens, D.; Johansson, K. E.; Jon-And, K.; Jorge, P. M.; Juste Rozas, A.; Kapliy, A.; Karpov, S. N.; Karyukhin, A. N.; Khandanyan, H.; Khramov, E.; Khubua, J.; Kim, H.; Klimek, P.; Korolkov, I.; Kruse, A.; Kulchitsky, Y.; Kurochkin, Y. A.; Lafarguette, P.; Lambert, D.; LeCompte, T.; Leitner, R.; Leone, S.; Liao, H.; Lie, K.; Lokajicek, M.; Lundberg, O.; Magalhaes Martins, P. J.; Maio, A.; Makouski, M.; Maneira, J.; Filho, L. Manhaes de Andrade; Manousakis-Katsikakis, A.; Martin, B.; Mchedlidze, G.; Meehan, S.; Mellado Garcia, B. R.; Meoni, E.; Merritt, F. S.; Meyer, C.; Miller, D. W.; Milstead, D. A.; Minashvili, I. A.; Mir, L. M.; Molander, S.; Montejo Berlingen, J.; Mosidze, M.; Myagkov, A. G.; Nemecek, S.; Nepomuceno, A. A.; Nguyen, D. H.; Nikolaenko, V.; Nilsson, P.; Nodulman, L.; Nordkvist, B.; Ohm, C. C.; Olariu, A.; Oleiro Seabra, L. F.; Onofre, A.; Oreglia, M. J.; Pallin, D.; Pantea, D.; Paredes Hernandez, D.; Pedraza Morales, M. I.; Pedro, R.; Martins, F. M. Pedro; Peng, H.; Penning, B.; Pilcher, J. E.; Pina, J.; Pleskot, V.; Plotnikova, E.; Podlyski, F.; Popeneciu, G. A.; Poveda, J.; Pravahan, R.; Pribyl, L.; Price, L. E.; Proudfoot, J.; Rocha de Lima, J. G.; Roda, C.; Roda Dos Santos, D.; Romano Saez, S. M.; Rossetti, V.; Ruiz-Martinez, A.; Rusakovich, N. A.; Salvachua Ferrando, B. M.; Santoni, C.; Santos, H.; Saraiva, J. G.; Says, L. P.; Schwartzman, A.; Scuri, F.; Shimizu, S.; Silva, J.; Silverstein, S. B.; Solans, C. A.; Solodkov, A. A.; Solovyanov, O. V.; Spalla, M.; Stanek, R. W.; Starchenko, E. A.; Starovoitov, P.; Stavina, P.; Stoicea, G.; Succurro, A.; Suhr, C.; Sumida, T.; Sykora, I.; Tas, P.; Tavares Delgado, A.; Tokár, S.; Tsiareshka, P. V.; Tsiskaridze, V.; Tudorache, V.; Tudorache, A.; Tuggle, J. M.; Tylmad, M.; Usai, G.; Valero, A.; Valery, L.; Valladolid Gallego, E.; Valls Ferrer, J. A.; Vazeille, F.; Veloso, F.; Vichou, I.; Vinogradov, V. B.; Viret, S.; Volpi, M.; Wang, C.; Weng, Z.; White, A.; Wilkens, H. G.; Yanush, S.; Yoshida, R.; Zhang, L.; Zhu, Y.; Zinonos, Z.; Zutshi, V.; Ženiš, T.; van Woerden, M. C.

    2016-10-01

    This article describes the Laser calibration system of the ATLAS hadronic Tile Calorimeter that has been used during the run 1 of the LHC . First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % for the end-caps. Finally, the detection and correction of timing mis-configuration of the Tile Calorimeter using the Laser system are also presented.

  2. Simulation of π0-γ Separation Study for Proposed CMS Forward Electromagnetic Calorimeter

    NASA Astrophysics Data System (ADS)

    Roy, Ashim; Jain, Shilpi; Banerjee, Sunanda; Bhattacharya, Satyaki; Majumder, Gobinda

    2016-10-01

    The Forward Electromagnetic Calorimeter of the CMS detector is going to be upgraded in the high luminosity running as the energy of the present Electromagnetic Calorimeter (PbWO4) will degrade in the high luminosity (luminosity 1034 cm -2 s -1) running due to extensive radiation (hadron flux 1013neutrons cm,-2). Shashlik Electromagnetic Calorimeter which consists of alternate layers of 1.5 mm LYSO(Ce) crystal plates and 2.5 mm Tungsten absorbers, was a proposal for high luminosity running. One of the performance points for any electromagnetic calorimeter is the ability to separate π0 s from true photons, since final states with photons are a clean and one of the most important final states in proton-proton collisions at the LHC. The objective of this project is to study the possibility of π0 and γ separation in the Shashlik detector using Multivariate Analysis (MVA) technique.

  3. Monte Carlo study of the influence of magnetic field on energy measurements in calorimeters

    NASA Astrophysics Data System (ADS)

    Abramov, V. V.

    1996-02-01

    The influence of magnetic field on energy measurements in calorimeters is studied by Monte Carlo methods. It is shown that magnetic field influence depends on type of incident particles and on material and thickness of absorber plates.

  4. The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1

    SciTech Connect

    Abdallah, J.; Alexa, C.; Coutinho, Y. Amaral; Santos, S. P. Amor Dos; Anderson, K. J.; Arabidze, G.; Araque, J. P.; Artamonov, A.; Asquith, L.; Astalos, R.; Mayes, J. Backus; Bartos, P.; Batkova, L.; Bertolucci, F.; Bylund, O. Bessidskaia; Castro, A. Blanco; Blazek, T.; Bohm, C.; Boumediene, D.; Boveia, A.; Brown, H.; Busato, E.; Calkins, R.; Calvet, D.; Calvet, S.; Toro, R. Camacho; Armadans, R. Caminal; Carli, T.; Carvalho, J.; Cascella, M.; Castro, N. F.; Cavasinni, V.; Cerqueira, A. S.; Chadelas, R.; Chakraborty, D.; Chekanov, S.; Chen, X.; Chikovani, L.; Choudalakis, G.; Cinca, D.; Ciubancan, M.; Clement, C.; Cole, S.; Constantinescu, S.; Costin, T.; Crouau, M.; Crozatier, C.; Cuciuc, C. -M.; De Sousa, M. J. Da Cunha Sargedas; Darmora, S.; Davidek, T.; Prete, T. Del; Dita, S.; Djobava, T.; Dolejsi, J.; Dotti, A.; Dubreuil, E.; Dunford, M.; Eriksson, D.; Errede, S.; Errede, D.; Faltova, J.; Farbin, A.; Febbraro, R.; Federic, P.; Feng, E. J.; Ferrer, A.; Fiascaris, M.; Fiolhais, M. C. N.; Fiorini, L.; Francavilla, P.; Torregrosa, E. Fullana; Galhardo, B.; Gellerstedt, K.; Ghodbane, N.; Giakoumopoulou, V.; Giangiobbe, V.; Giokaris, N.; Glonti, G. L.; Gomes, A.; Parra, G. Gonzalez; Grenier, P.; Grinstein, S.; Gris, Ph.; Guicheney, C.; Hakobyan, H.; Hard, A. S.; Harkusha, S.; Heelan, L.; Helsens, C.; Correia, A. M. Henriques; Jiménez, Y. Hernández; Hernandez, C. M.; Higón-Rodriguez, E.; Hurwitz, M.; Huseynov, N.; Huston, J.; Plante, I. Jen-La; Jennens, D.; Johansson, K. E.; Jon-And, K.; Jorge, P. M.; Rozas, A. Juste; Kapliy, A.; Karpov, S. N.; Karyukhin, A. N.; Khandanyan, H.; Khramov, E.; Khubua, J.; Kim, H.; Klimek, P.; Korolkov, I.; Kruse, A.; Kulchitsky, Y.; Kurochkin, Y. A.; Lafarguette, P.; Lambert, D.; LeCompte, T.; Leitner, R.; Leone, S.; Liao, H.; Lie, K.; Lokajicek, M.; Lundberg, O.; Martins, P. J. Magalhaes; Maio, A.; Makouski, M.; Maneira, J.; Filho, L. Manhaes de Andrade; Manousakis-Katsikakis, A.; Martin, B.; Mchedlidze, G.; Meehan, S.; Garcia, B. R. Mellado; Meoni, E.; Merritt, F. S.; Meyer, C.; Miller, D. W.; Milstead, D. A.; Minashvili, I. A.; Mir, L. M.; Molander, S.; Berlingen, J. Montejo; Mosidze, M.; Myagkov, A. G.; Nemecek, S.; Nepomuceno, A. A.; Nguyen, D. H.; Nikolaenko, V.; Nilsson, P.; Nodulman, L.; Nordkvist, B.; Ohm, C. C.; Olariu, A.; Seabra, L. F. Oleiro; Onofre, A.; Oreglia, M. J.; Pallin, D.; Pantea, D.; Hernandez, D. Paredes; Morales, M. I. Pedraza; Pedro, R.; Martins, F. M. Pedro; Peng, H.; Penning, B.; Pilcher, J. E.; Pina, J.; Pleskot, V.; Plotnikova, E.; Podlyski, F.; Popeneciu, G. A.; Poveda, J.; Pravahan, R.; Pribyl, L.; Price, L. E.; Proudfoot, J.; de Lima, J. G. Rocha; Roda, C.; Santos, D. Roda Dos; Saez, S. M. Romano; Rossetti, V.; Ruiz-Martinez, A.; Rusakovich, N. A.; Ferrando, B. M. Salvachua; Santoni, C.; Santos, H.; Saraiva, J. G.; Says, L. P.; Schwartzman, A.; Scuri, F.; Shimizu, S.; Silva, J.; Silverstein, S. B.; Solans, C. A.; Solodkov, A. A.; Solovyanov, O. V.; Spalla, M.; Stanek, R. W.; Starchenko, E. A.; Starovoitov, P.; Stavina, P.; Stoicea, G.; Succurro, A.; Suhr, C.; Sumida, T.; Sykora, I.; Tas, P.; Delgado, A. Tavares; Tokár, S.; Tsiareshka, P. V.; Tsiskaridze, V.; Tudorache, V.; Tudorache, A.; Tuggle, J. M.; Tylmad, M.; Usai, G.; Valero, A.; Valery, L.; Gallego, E. Valladolid; Ferrer, J. A. Valls; Vazeille, F.; Veloso, F.; Vichou, I.; Vinogradov, V. B.; Viret, S.; Volpi, M.; Wang, C.; Weng, Z.; White, A.; Wilkens, H. G.; Yanush, S.; Yoshida, R.; Zhang, L.; Zhu, Y.; Zinonos, Z.; Zutshi, V.; Ženiš, T.; van Woerden, M. C.

    2016-10-12

    This article describes the Laser calibration system of the ATLAS hadronic Tile Calorimeter that has been used during the run 1 of the LHC . First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % for the end-caps. Lastly, the detection and correction of timing mis-configuration of the Tile Calorimeter using the Laser system are also presented.

  5. Optimization of light collection scheme for forward hadronic calorimeter for STAR experiment at RHIC

    NASA Astrophysics Data System (ADS)

    Sergeeva, Maria

    2013-10-01

    We present the results of the optimization of a light collection scheme for a prototype of a sampling compensated hadronic calorimeter for upgrade of the STAR detector at RHIC (BNL). The absolute light yield and uniformity of light collection were measured with the full scale calorimeter tower for different types of reflecting materials, realistic mechanical tolerances for tower assembly and type of coupling between WLS bars and photo detectors. Measurements were performed with conventional PMTs and silicone photo multipliers. The results of these measurements were used to evaluate the influence of the optical collection scheme on the response of the calorimeter using GEANT4 MC. A large prototype of this calorimeter is presently under construction with the beam test scheduled early next year at FNAL.

  6. The electromagnetic calorimeter for the solenoidal tracker at RHIC. A Conceptual Design Report

    SciTech Connect

    Beddo, M.E.; Bielick, E.; Dawson, J.W.; The STAR EMC Collaboration

    1993-09-22

    This report discusses the following on the electromagnetic calorimeter for the solenoidal tracker at RHIC: conceptual design; the physics of electromagnetic calorimetry in STAR; trigger capability; integration into STAR; and cost, schedule, manpower, and funding.

  7. Prototype tests for a highly granular scintillator-based hadron calorimeter

    NASA Astrophysics Data System (ADS)

    Krüger, K.; CALICE Collaboration

    2015-02-01

    Within the CALICE collaboration, several concepts for the hadronic calorimeter of a future linear collider detector are studied. After having demonstrated the capabilities of the measurement methods in "physics prototypes", the focus now lies on improving their implementation in"technological prototypes", that are scalable to the full linear collider detector. The Analog Hadron Calorimeter (AHCAL) concept is a sampling calorimeter of tungsten or steel absorber plates and plastic scintillator tiles read out by silicon photomultipliers as active material. In the AHCAL technological prototype, the front-end chips are integrated into the active layers of the calorimeter and are designed for minimal power consumption. The versatile electronics allows the prototype to be equipped with different types of scintillator tiles and SiPMs. The current status of the AHCAL engineering prototype is shown and recent beam test measurements as well as plans for future hadron beam tests with a larger prototype will be discussed.

  8. Experimental results and experience with the KfK-tritium-calorimeter

    SciTech Connect

    Kapulla, H.; Heine, R.

    1995-10-01

    For the tritium assay at the Tritium Laboratory Karlsruhe (TLK) which started operation in Nov.94 an isothermal shield calorimeter was built. The calibration of the calorimeter was performed with an electrically heated simulator covering the range between 1 mW and about 2 W. After the calibration tritium activities in four Amersham uranium getter containers were determined. The excellent reproducibility and high precision of the measurements with the KfK-calorimeter was shown. The tritium activity inventories could be determined with relative standard deviations from the average value of the order of 0.01% to 0.1% depending on the activity level. These results demonstrate the suitability of the KfK-calorimeter as a nondestructive method for a careful assay of tritium. 3 refs., 11 figs., 2 tabs.

  9. Study of the performance of a semi-digital hadronic calorimeter using Monte Carlo techniques

    NASA Astrophysics Data System (ADS)

    Elmahroug, Y.; Tellili, B.; Souga, C.

    2014-04-01

    The Particle Flow Algorithm is one of the main concepts that will be used to measure the energies of hadronic jets at a future International Linear Collider. This method requires a highly granular hadronic calorimeter to measure the energy of jets with a good precision. The Semi-Digital Hadronic Calorimeter using glass resistive plate chambers as sensitive medium is one of the hadronic calorimeters which is used in conjunction with the particle flow method. In this paper, the performance of Semi-Digital Hadronic Calorimeter using glass resistive plate chambers as active elements has been studied by using the GEANT4 simulations. Its main operational characteristics such as mean response and energy resolution have been examined.

  10. On the massless gap'' adjustment of detected energy for passive material in front of a calorimeter

    SciTech Connect

    Trost, H.J.

    1992-01-31

    I have designed a correction scheme for energy losses in passive material in front of a calorimeter based on the massless gap'' idea. I use a flexible geometry model of a calorimeter design for SDC outside of a solenoidal coil made of aluminium cylinders of adjustable thickness. The signal from the first radiation length of active calorimetry is scaled dependent on the incoming and observed energies of the shower. A reasonable recovery of the resolution of an unobstructed calorimeter is achieved using correction factors that depend only upon the total thickness of passive material. Thus a useful correction may be built into the hardware by increasing the amount of scintillator in the first radiation length of the active calorimeter. The distribution of correction factors determined event-by-event indicate that an additional dependence on the observed signal in the massless gap and total incident energy is clearly present.

  11. On the ``massless gap`` adjustment of detected energy for passive material in front of a calorimeter

    SciTech Connect

    Trost, H.J.

    1992-01-31

    I have designed a correction scheme for energy losses in passive material in front of a calorimeter based on the ``massless gap`` idea. I use a flexible geometry model of a calorimeter design for SDC outside of a solenoidal coil made of aluminium cylinders of adjustable thickness. The signal from the first radiation length of active calorimetry is scaled dependent on the incoming and observed energies of the shower. A reasonable recovery of the resolution of an unobstructed calorimeter is achieved using correction factors that depend only upon the total thickness of passive material. Thus a useful correction may be built into the hardware by increasing the amount of scintillator in the first radiation length of the active calorimeter. The distribution of correction factors determined event-by-event indicate that an additional dependence on the observed signal in the massless gap and total incident energy is clearly present.

  12. The Laser calibration of the ATLAS Tile Calorimeter during the LHC run 1

    DOE PAGES

    Abdallah, J.; Alexa, C.; Coutinho, Y. Amaral; ...

    2016-10-12

    This article describes the Laser calibration system of the ATLAS hadronic Tile Calorimeter that has been used during the run 1 of the LHC . First, the stability of the system associated readout electronics is studied. It is found to be stable with variations smaller than 0.6 %. Then, the method developed to compute the calibration constants, to correct for the variations of the gain of the calorimeter photomultipliers, is described. These constants were determined with a statistical uncertainty of 0.3 % and a systematic uncertainty of 0.2 % for the central part of the calorimeter and 0.5 % formore » the end-caps. Lastly, the detection and correction of timing mis-configuration of the Tile Calorimeter using the Laser system are also presented.« less

  13. Impact accelerations

    NASA Technical Reports Server (NTRS)

    Vongierke, H. E.; Brinkley, J. W.

    1975-01-01

    The degree to which impact acceleration is an important factor in space flight environments depends primarily upon the technology of capsule landing deceleration and the weight permissible for the associated hardware: parachutes or deceleration rockets, inflatable air bags, or other impact attenuation systems. The problem most specific to space medicine is the potential change of impact tolerance due to reduced bone mass and muscle strength caused by prolonged weightlessness and physical inactivity. Impact hazards, tolerance limits, and human impact tolerance related to space missions are described.

  14. Late acceleration of glomerular filtration rate decline is a risk for hemodialysis catheter use in patients with established nephrology chronic kidney disease care.

    PubMed

    Chin, Andrew I; Nguyen, Tuan A; Dinesh, Kumar P; Morfin, José A

    2015-07-01

    Chronic kidney disease (CKD) patients with established nephrology care have a high rate of tunneled dialysis catheters (TDC) as first vascular access when transitioning to hemodialysis (HD). We sought to identify factors associated with this problem. Patients who started HD and had prior CKD care within our renal clinic were categorized according to access type at incident HD. Clinical factors, all estimated glomerular filtration rates (eGFR), renal clinic attendance records, hospital admissions in the 6 months preceding HD start, and patient participation in predialysis education course were analyzed. Three hundred thirty-eight patients initiated HD, 107 received pre-HD CKD care within our clinics. Seventy patients started with a TDC. All groups started HD at similar eGFR values. The trajectory of eGFR decline in the 6 months prior to HD start was significantly more rapid in the TDC group. Patients in the TDC group had more acute health events in the prior 6 months. Multivariate modeling showed that failure to attend a predialysis education course and having a more rapid rate of eGFR decline in the 6 months prior to dialysis initiation were both associated with TDC use. Patients with CKD nephrology care who initiated HD with a TDC as first vascular access had a more rapid rate of decline in eGFR in the months preceding dialysis start and were less likely to have attended our predialysis education course. This appears to correspond with the observed increased number of emergency and hospital visits in the 6 months prior to end-stage renal disease.

  15. An experimental study on burning behaviors of 18650 lithium ion batteries using a cone calorimeter

    NASA Astrophysics Data System (ADS)

    Fu, Yangyang; Lu, Song; Li, Kaiyuan; Liu, Changchen; Cheng, Xudong; Zhang, Heping

    2015-01-01

    Numerous of lithium ion battery fires and explosions enhance the need of precise risk assessments on batteries. In the current study, 18650 lithium ion batteries at different states of charge are tested using a cone calorimeter to study the burning behaviors under an incident heat flux of 50 kW m-2. Several parameters are measured, including mass loss rate, time to ignition, time to explosion, heat release rate (HRR), the surface temperature and concentration of toxic gases. Although small quantities of oxygen are released from the lithium ion battery during burning, it is estimated that the energy, consuming oxygen released from the lithium ion battery, accounts for less than 13% of total energy released by a fully charged lithium ion battery. The experimental results show that the peak HRR and concentration of toxic gases rise with the increasing the states of charge, whereas the time to ignition and time to explosion decrease. The test results of the fully charged lithium ion batteries at three different incident heat fluxes show that the peak HRR increases from 6.2 to 9.1 kW and the maximum surface temperature increases from 662 to 934 °C as the incident heat flux increases from 30 to 60 kW m-2.

  16. Array-scale performance of TES X-ray Calorimeters Suitable for Constellation-X

    NASA Technical Reports Server (NTRS)

    Kilbourne, C. A.; Bandler, S. R.; Brown, A. D.; Chervenak, J. A.; Eckart, M. E.; Finkbeiner, F. M.; Iyomoto, N.; Kelley, R. L.; Porter, F. S.; Smith, S. J.; Doriese, W. B.; Irwin, K. D.

    2008-01-01

    Having developed a transition-edge-sensor (TES) calorimeter design that enables high spectral resolution in high fill-factor arrays, we now present array-scale results from 32-pixel arrays of identical closely packed TES pixels. Each pixel in such an array contains a Mo/Au bilayer with a transition temperature of 0.1 K and an electroplated Au or Au/Bi xray absorber. The pixels in an array have highly uniform physical characteristics and performance. The arrays are easy to operate due to the range of bias voltages and heatsink temperatures over which solution better than 3 eV at 6 keV can be obtained. Resolution better than 3 eV has also been obtained with 2x8 time-division SQUID multiplexing. We will present the detector characteristics and show spectra acquired through the read-out chain from the multiplexer electronics through the demultiplexer software to real-time signal processing. We are working towards demonstrating this performance over the range of count rates expected in the observing program of the Constellation-X observatory. We mill discuss the impact of increased counting rate on spectral resolution, including the effects of crosstalk and optimal-filtering dead time.

  17. A New Whole Room Indirect Calorimeter for Measurement of the Energetics of Exercise

    PubMed Central

    Rising, Russell; Whyte, Kathryn; Albu, Jeanine; Pi-Sunyer, Xavier

    2017-01-01

    The purpose of this study was to compare the accuracy of exercise energy expenditure (EXEE) measurements from a metabolic cart (HG_MC) to that obtained with a new exercise whole room indirect calorimeter (EX_WRIC). First, the HG_MC and the EX_WRIC were subjected to 10, 30-min ethanol (99.8% purity) and propane (99.5% purity) combustion validations, respectively, for EE, ventilation rates (liters) of oxygen (VO2), carbon dioxide (VCO2), and the respiratory quotient (RQ; VCO2/VO2). Then, 15 healthy adults (13 men and 2 women) cycled at 65% age predicted heart rate max for random determination of their EXEE, VO2, VCO2 and RQ after a 12-hr fast with both the HG-MC and EX_WRIC. Comparing stoichiometry to combustion, the HG_MC underestimated EE (P<0.05), VO2 (P<0.05), VCO2 (P<0.05), and RQ (P<0.05) while no differences were found for the EX_WRIC. The EXEE and VO2 were lower (P<0.05) while RQ was greater (P<0.05) when measured with the HG_MC versus the EX_WRIC. The EX_WRIC was more accurate than the HG_MC without the related tethered connections. PMID:28179805

  18. A measurement of E/{pi} for a fast lead liquid argon calorimeter

    SciTech Connect

    Makowiecki, D.; Gordon, H.A.; Ma, H.; Murtagh, M.; Radeka, V.; Rahm, D.; Rescia, S.; Abrams, G.S.; Groom, D.E.; Kirsten, F.; Levi, M.; Siegrist, J.; Amako, K.; Inaba, O.; Kondo, T.; Baden, A.R.; Fong, D.; Hadley, N.; Kunori, S.; Skuja, A.; Bowen, T.; Forden, G.; Jenkins, E.; Johns, K.; Rutherfoord, J.; Shupe, M.; Burnett, T.; Cook, V.; Davisson, R.; Mockett, P.; Rothberg, J.; Williams, R.W.; Cremaldi, L.; Reidy, J.; Summers, D.; DiGiacomo, N.; Draper, P.; Ferbel, T.; Lobkowicz, F.; Faust, J.; Hauptman, J.; Pang, M.; Gabriel, T.A.; Hagopian, V.; Womersley, J.; Handler, T.; Hitlin, D.; Mulholland, G.T.; Watanabe, Y.; Weerts, H.

    1990-12-31

    The NA34 (HELIOS) calorimeter has measured e/{pi} {congruent} 1.1 in a uranium/liquid argon calorimeter with a shaping time of 135 nsec. Lead may be a viable alternative, but e/{pi} must first be measured at fast shaping times in lead. We re preparing to measure e/{pi} at momenta ranging from 0.5 to 20 GeV/c and with shaping times of 50, 100 and 150 nsec.

  19. The SOUDAN 2 detector The design and construction of the tracking calorimeter modules

    NASA Astrophysics Data System (ADS)

    Allison, W. W. M.; Alner, G. J.; Ambats, I.; Ayres, D. S.; Balka, L. J.; Barr, G. D.; Barrett, W. L.; Benjamin, D.; Bode, C.; Border, P. M.; Brooks, C. B.; Cobb, J. H.; Cockerill, D. J. A.; Coover, K.; Cotton, R. J.; Courant, H.; Dahlin, B. B.; DasGupta, U.; Dawson, J. W.; Demuth, D. M.; Edwards, V. W.; Ewen, B.; Fields, T. H.; Garcia-Garcia, C.; Gallagher, H. M.; Giles, R. H.; Giller, G. L.; Goodman, M. C.; Gray, R. N.; Heppelmann, S.; Hill, N.; Hoftiezer, J. H.; Jankowski, D. J.; Johns, K.; Joyce, T.; Kafka, T.; Kasahara, S. M. S.; Kirby-Gallagher, L. M.; Kochocki, J.; Leeson, W.; Litchfield, P. J.; Longley, N. P.; Lopez, F. V.; Lowe, M. J.; Mann, W. A.; Marshak, M. L.; May, E. N.; Maxam, D.; McMaster, L.; Milburn, R.; Miller, W. H.; Minor, C. P.; Mondal, N.; Mualem, L.; Napier, A.; Nelson, E. M.; Nickson, R.; Oliver, W.; Pearce, G. F.; Perkins, D. H.; Peterson, E. A.; Price, L. E.; Roback, D. M.; Rosen, D. B.; Ruddick, K.; Saitta, B.; Schmid, D. J.; Schlereth, J.; Schneps, J.; Schub, M. H.; Seidlein, R. V.; Shield, P. D.; Shupe, M. A.; Spear, S.; Stassinakis, A.; Sundaralingam, N.; Thomson, M. A.; Thron, J. L.; Vassiliev, V.; Villaume, G.; Wakely, S. P.; Wall, D.; Wallis, E. W. G.; Weems, L.; Werkema, S. J.; West, N.; Wielgosz, U.; Woods, C. A.; Yarker, S.

    1996-02-01

    SOUDAN 2 is a 960-ton tracking calorimeter which has been constructed to search for nucleon decay and other phenomena. The full detector consists of 224 calorimeter modules each weighing 4.3 tons. The design and construction of the modules are described. The modules consist of finely segmented iron instrumented with 1 m long drift tubes of 15 mm internal diameter. The tubes enable three spatial coordinates and d E/d x to be recorded for charged particles traversing the tubes.

  20. Hadronic Shower Validation Experience for the ATLAS End-Cap Calorimeter

    SciTech Connect

    Kiryunin, A. E.; Salihagic, D.

    2007-03-19

    Validation of GEANT4 hadronic physics models is carried out by comparing experimental data from beam tests of modules of the ATLAS end-cap calorimeters with GEANT4 based simulations. Two physics lists (LHEP and QGSP) for the simulation of hadronic showers are evaluated. Calorimeter performance parameters like the energy resolution and response for charged pions and shapes of showers are studied. Comparison with GEANT3 predictions is done as well.