Science.gov

Sample records for accelerator neutron sources

  1. Accelerator based epithermal neutron source

    NASA Astrophysics Data System (ADS)

    Taskaev, S. Yu.

    2015-11-01

    We review the current status of the development of accelerator sources of epithermal neutrons for boron neutron capture therapy (BNCT), a promising method of malignant tumor treatment. Particular attention is given to the source of epithermal neutrons on the basis of a new type of charged particle accelerator: tandem accelerator with vacuum insulation and lithium neutron-producing target. It is also shown that the accelerator with specialized targets makes it possible to generate fast and monoenergetic neutrons, resonance and monoenergetic gamma-rays, alpha-particles, and positrons.

  2. ACCELERATOR BASED CONTINUOUS NEUTRON SOURCE.

    SciTech Connect

    SHAPIRO,S.M.; RUGGIERO,A.G.; LUDEWIG,H.

    2003-03-25

    Until the last decade, most neutron experiments have been performed at steady-state, reactor-based sources. Recently, however, pulsed spallation sources have been shown to be very useful in a wide range of neutron studies. A major review of neutron sources in the US was conducted by a committee chaired by Nobel laureate Prof. W. Kohn: ''Neutron Sources for America's Future-BESAC Panel on Neutron Sources 1/93''. This distinguished panel concluded that steady state and pulsed sources are complementary and that the nation has need for both to maintain a balanced neutron research program. The report recommended that both a new reactor and a spallation source be built. This complementarity is recognized worldwide. The conclusion of this report is that a new continuous neutron source is needed for the second decade of the 20 year plan to replace aging US research reactors and close the US neutron gap. it is based on spallation production of neutrons using a high power continuous superconducting linac to generate protons impinging on a heavy metal target. There do not appear to be any major technical challenges to the building of such a facility since a continuous spallation source has been operating in Switzerland for several years.

  3. An Accelerator Neutron Source for BNCT

    SciTech Connect

    Blue, Thomas, E

    2006-03-14

    The overall goal of this project was to develop an accelerator-based neutron source (ABNS) for Boron Neutron Capture Therapy (BNCT). Specifically, our goals were to design, and confirm by measurement, a target assembly and a moderator assembly that would fulfill the design requirements of the ABNS. These design requirements were 1) that the neutron field quality be as good as the neutron field quality for the reactor-based neutron sources for BNCT, 2) that the patient treatment time be reasonable, 3) that the proton current required to treat patients in reasonable times be technologially achievable at reasonable cost with good reliability, and accelerator space requirements which can be met in a hospital, and finally 4) that the treatment be safe for the patients.

  4. The Spallation Neutron Source accelerator system design

    NASA Astrophysics Data System (ADS)

    Henderson, S.; Abraham, W.; Aleksandrov, A.; Allen, C.; Alonso, J.; Anderson, D.; Arenius, D.; Arthur, T.; Assadi, S.; Ayers, J.; Bach, P.; Badea, V.; Battle, R.; Beebe-Wang, J.; Bergmann, B.; Bernardin, J.; Bhatia, T.; Billen, J.; Birke, T.; Bjorklund, E.; Blaskiewicz, M.; Blind, B.; Blokland, W.; Bookwalter, V.; Borovina, D.; Bowling, S.; Bradley, J.; Brantley, C.; Brennan, J.; Brodowski, J.; Brown, S.; Brown, R.; Bruce, D.; Bultman, N.; Cameron, P.; Campisi, I.; Casagrande, F.; Catalan-Lasheras, N.; Champion, M.; Champion, M.; Chen, Z.; Cheng, D.; Cho, Y.; Christensen, K.; Chu, C.; Cleaves, J.; Connolly, R.; Cote, T.; Cousineau, S.; Crandall, K.; Creel, J.; Crofford, M.; Cull, P.; Cutler, R.; Dabney, R.; Dalesio, L.; Daly, E.; Damm, R.; Danilov, V.; Davino, D.; Davis, K.; Dawson, C.; Day, L.; Deibele, C.; Delayen, J.; DeLong, J.; Demello, A.; DeVan, W.; Digennaro, R.; Dixon, K.; Dodson, G.; Doleans, M.; Doolittle, L.; Doss, J.; Drury, M.; Elliot, T.; Ellis, S.; Error, J.; Fazekas, J.; Fedotov, A.; Feng, P.; Fischer, J.; Fox, W.; Fuja, R.; Funk, W.; Galambos, J.; Ganni, V.; Garnett, R.; Geng, X.; Gentzlinger, R.; Giannella, M.; Gibson, P.; Gillis, R.; Gioia, J.; Gordon, J.; Gough, R.; Greer, J.; Gregory, W.; Gribble, R.; Grice, W.; Gurd, D.; Gurd, P.; Guthrie, A.; Hahn, H.; Hardek, T.; Hardekopf, R.; Harrison, J.; Hatfield, D.; He, P.; Hechler, M.; Heistermann, F.; Helus, S.; Hiatt, T.; Hicks, S.; Hill, J.; Hill, J.; Hoff, L.; Hoff, M.; Hogan, J.; Holding, M.; Holik, P.; Holmes, J.; Holtkamp, N.; Hovater, C.; Howell, M.; Hseuh, H.; Huhn, A.; Hunter, T.; Ilg, T.; Jackson, J.; Jain, A.; Jason, A.; Jeon, D.; Johnson, G.; Jones, A.; Joseph, S.; Justice, A.; Kang, Y.; Kasemir, K.; Keller, R.; Kersevan, R.; Kerstiens, D.; Kesselman, M.; Kim, S.; Kneisel, P.; Kravchuk, L.; Kuneli, T.; Kurennoy, S.; Kustom, R.; Kwon, S.; Ladd, P.; Lambiase, R.; Lee, Y. Y.; Leitner, M.; Leung, K.-N.; Lewis, S.; Liaw, C.; Lionberger, C.; Lo, C. C.; Long, C.; Ludewig, H.; Ludvig, J.; Luft, P.; Lynch, M.; Ma, H.; MacGill, R.; Macha, K.; Madre, B.; Mahler, G.; Mahoney, K.; Maines, J.; Mammosser, J.; Mann, T.; Marneris, I.; Marroquin, P.; Martineau, R.; Matsumoto, K.; McCarthy, M.; McChesney, C.; McGahern, W.; McGehee, P.; Meng, W.; Merz, B.; Meyer, R.; Meyer, R.; Miller, B.; Mitchell, R.; Mize, J.; Monroy, M.; Munro, J.; Murdoch, G.; Musson, J.; Nath, S.; Nelson, R.; Nelson, R.; O`Hara, J.; Olsen, D.; Oren, W.; Oshatz, D.; Owens, T.; Pai, C.; Papaphilippou, I.; Patterson, N.; Patterson, J.; Pearson, C.; Pelaia, T.; Pieck, M.; Piller, C.; Plawski, T.; Plum, M.; Pogge, J.; Power, J.; Powers, T.; Preble, J.; Prokop, M.; Pruyn, J.; Purcell, D.; Rank, J.; Raparia, D.; Ratti, A.; Reass, W.; Reece, K.; Rees, D.; Regan, A.; Regis, M.; Reijonen, J.; Rej, D.; Richards, D.; Richied, D.; Rode, C.; Rodriguez, W.; Rodriguez, M.; Rohlev, A.; Rose, C.; Roseberry, T.; Rowton, L.; Roybal, W.; Rust, K.; Salazer, G.; Sandberg, J.; Saunders, J.; Schenkel, T.; Schneider, W.; Schrage, D.; Schubert, J.; Severino, F.; Shafer, R.; Shea, T.; Shishlo, A.; Shoaee, H.; Sibley, C.; Sims, J.; Smee, S.; Smith, J.; Smith, K.; Spitz, R.; Staples, J.; Stein, P.; Stettler, M.; Stirbet, M.; Stockli, M.; Stone, W.; Stout, D.; Stovall, J.; Strelo, W.; Strong, H.; Sundelin, R.; Syversrud, D.; Szajbler, M.; Takeda, H.; Tallerico, P.; Tang, J.; Tanke, E.; Tepikian, S.; Thomae, R.; Thompson, D.; Thomson, D.; Thuot, M.; Treml, C.; Tsoupas, N.; Tuozzolo, J.; Tuzel, W.; Vassioutchenko, A.; Virostek, S.; Wallig, J.; Wanderer, P.; Wang, Y.; Wang, J. G.; Wangler, T.; Warren, D.; Wei, J.; Weiss, D.; Welton, R.; Weng, J.; Weng, W.-T.; Wezensky, M.; White, M.; Whitlatch, T.; Williams, D.; Williams, E.; Wilson, K.; Wiseman, M.; Wood, R.; Wright, P.; Wu, A.; Ybarrolaza, N.; Young, K.; Young, L.; Yourd, R.; Zachoszcz, A.; Zaltsman, A.; Zhang, S.; Zhang, W.; Zhang, Y.; Zhukov, A.

    2014-11-01

    The Spallation Neutron Source (SNS) was designed and constructed by a collaboration of six U.S. Department of Energy national laboratories. The SNS accelerator system consists of a 1 GeV linear accelerator and an accumulator ring providing 1.4 MW of proton beam power in microsecond-long beam pulses to a liquid mercury target for neutron production. The accelerator complex consists of a front-end negative hydrogen-ion injector system, an 87 MeV drift tube linear accelerator, a 186 MeV side-coupled linear accelerator, a 1 GeV superconducting linear accelerator, a 248-m circumference accumulator ring and associated beam transport lines. The accelerator complex is supported by ~100 high-power RF power systems, a 2 K cryogenic plant, ~400 DC and pulsed power supply systems, ~400 beam diagnostic devices and a distributed control system handling ~100,000 I/O signals. The beam dynamics design of the SNS accelerator is presented, as is the engineering design of the major accelerator subsystems.

  5. Observation of Neutron Skyshine from an Accelerator Based Neutron Source

    SciTech Connect

    Franklyn, C. B.

    2011-12-13

    A key feature of neutron based interrogation systems is the need for adequate provision of shielding around the facility. Accelerator facilities adapted for fast neutron generation are not necessarily suitably equipped to ensure complete containment of the vast quantity of neutrons generated, typically >10{sup 11} n{center_dot}s{sup -1}. Simulating the neutron leakage from a facility is not a simple exercise since the energy and directional distribution can only be approximated. Although adequate horizontal, planar shielding provision is made for a neutron generator facility, it is sometimes the case that vertical shielding is minimized, due to structural and economic constraints. It is further justified by assuming the atmosphere above a facility functions as an adequate radiation shield. It has become apparent that multiple neutron scattering within the atmosphere can result in a measurable dose of neutrons reaching ground level some distance from a facility, an effect commonly known as skyshine. This paper describes a neutron detection system developed to monitor neutrons detected several hundred metres from a neutron source due to the effect of skyshine.

  6. Observation of Neutron Skyshine from an Accelerator Based Neutron Source

    NASA Astrophysics Data System (ADS)

    Franklyn, C. B.

    2011-12-01

    A key feature of neutron based interrogation systems is the need for adequate provision of shielding around the facility. Accelerator facilities adapted for fast neutron generation are not necessarily suitably equipped to ensure complete containment of the vast quantity of neutrons generated, typically >1011 nṡs-1. Simulating the neutron leakage from a facility is not a simple exercise since the energy and directional distribution can only be approximated. Although adequate horizontal, planar shielding provision is made for a neutron generator facility, it is sometimes the case that vertical shielding is minimized, due to structural and economic constraints. It is further justified by assuming the atmosphere above a facility functions as an adequate radiation shield. It has become apparent that multiple neutron scattering within the atmosphere can result in a measurable dose of neutrons reaching ground level some distance from a facility, an effect commonly known as skyshine. This paper describes a neutron detection system developed to monitor neutrons detected several hundred metres from a neutron source due to the effect of skyshine.

  7. BINP accelerator based epithermal neutron source.

    PubMed

    Aleynik, V; Burdakov, A; Davydenko, V; Ivanov, A; Kanygin, V; Kuznetsov, A; Makarov, A; Sorokin, I; Taskaev, S

    2011-12-01

    Innovative facility for neutron capture therapy has been built at BINP. This facility is based on compact vacuum insulation tandem accelerator designed to produce proton current up to 10 mA. Epithermal neutrons are proposed to be generated by 1.915-2.5 MeV protons bombarding a lithium target using (7)Li(p,n)(7)Be threshold reaction. In the article, diagnostic techniques for proton beam and neutrons developed are described, results of experiments on proton beam transport and neutron generation are shown, discussed, and plans are presented. PMID:21439836

  8. First neutron generation in the BINP accelerator based neutron source.

    PubMed

    Bayanov, B; Burdakov, A; Chudaev, V; Ivanov, A; Konstantinov, S; Kuznetsov, A; Makarov, A; Malyshkin, G; Mekler, K; Sorokin, I; Sulyaev, Yu; Taskaev, S

    2009-07-01

    Pilot innovative facility for neutron capture therapy was built at Budker Institute of Nuclear Physics, Novosibirsk. This facility is based on a compact vacuum insulation tandem accelerator designed to produce proton current up to 10 mA. Epithermal neutrons are proposed to be generated by 1.915 MeV protons bombarding a lithium target using (7)Li(p,n)(7)Be threshold reaction. The results of the first experiments on neutron generation are reported and discussed. PMID:19375928

  9. High Intensity Accelerator and Neutron Source in China

    SciTech Connect

    Guan Xialing; Wei, J.; Loong Chun

    2011-06-28

    High intensity Accelerator is being studied all over world for numerous applications, which includes the waste transmutation, spallation neutron source and material irradiation facilities. The R/D activities of the technology of High intensity accelerator are also developed in China for some year, and have some good facilities around China. This paper will reports the status of some high intensity accelerators and neutron source in China, which including ADS/RFQ; CARR; CSNS; PKUNIFTY and CPHS. This paper will emphatically report the Compact Pulsed Hadron Source (CPHS) led by the Department of Engineering Physics of Tsinghua University in Beijing, China.

  10. Accelerator based epithermal neutron source for neutron capture therapy

    SciTech Connect

    Brugger, R.; Kunze, J.

    1991-05-01

    Several investigators have suggested that a charged particle accelerator with light element reactions might be able to produce enough epithermal neutrons to be useful in Neutron Capture Therapy. The reaction choice so far has been the Li(p,n) reaction with protons up to 2.5 MeV. A moderator around the target would reduce the faster neutrons down to the epithermal energy region. The goals of the present research are: identify better reactions; improve the moderators; and find better combinations of 1 and 2. The target is to achieve, at the patient location, an epithermal neutron current of greater than 10{sup 9}n/cm{sup 2}sec, with a dose to tissue from the neutrons alone of less than 10{sup {minus}10} rads/n and a dose from the gamma rays in the beam of less than 10{sup {minus}10} rads/n.

  11. First experiments on neutron detection on the accelerator-based source for boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Kuznetsov, A. S.; Malyshkin, G. N.; Makarov, A. N.; Sorokin, I. N.; Sulyaev, Yu. S.; Taskaev, S. Yu.

    2009-04-01

    A pilot accelerator-based source of epithermal neutrons, which is intended for wide application in clinics for boron neutron capture therapy, has been constructed at the Budker Institute of Nuclear Physics (Novosibirsk). A stationary proton beam has been obtained and near-threshold neutron generation regime has been realized. Results of the first experiments on neutron generation using the proposed source are described.

  12. Accelerator-driven neutron source for cargo screening

    NASA Astrophysics Data System (ADS)

    Ludewigt, B. A.; Bleuel, D. L.; Hoff, M. D.; Kwan, J. W.; Li, D.; Ratti, A.; Staples, J. W.; Virostek, S. P.; Wells, R. P.

    2007-08-01

    Advanced neutron interrogation systems for screening sea-land cargo containers for shielded special nuclear materials (SNM) require a high-yield neutron source to achieve the desired detection probability, false alarm rate, and throughput. The design of an accelerator-driven neutron source is described that utilizes the D(d,n)3He reaction to produce a forward directed beam of up to 8.5 MeV neutrons. The key components of the neutron source are a high-current radio frequency quadrupole (RFQ) accelerator and a neutron production gas target. The 5.1 m long, 200 MHz RFQ accelerates a 40 mA deuteron beam from a microwave-driven ion source coupled to an electrostatic low energy beam transport (LEBT) system to 6 MeV. At a 5% duty factor, the time-average D+ beam current on target is 1.5 mA. A thin entrance window has been designed for the deuterium gas target that can withstand the high beam power and the gas pressure. The source will be capable of delivering a flux >1 × 107 n/(cm2 s) at a distance of 2.5 m from the target and will allow full testing and demonstration of a cargo screening system based on neutron stimulated SNM signatures.

  13. Accelerator shield design of KIPT neutron source facility

    SciTech Connect

    Zhong, Z.; Gohar, Y.

    2013-07-01

    Argonne National Laboratory (ANL) of the United States and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of a neutron source facility at KIPT utilizing an electron-accelerator-driven subcritical assembly. Electron beam power is 100 kW, using 100 MeV electrons. The facility is designed to perform basic and applied nuclear research, produce medical isotopes, and train young nuclear specialists. The biological shield of the accelerator building is designed to reduce the biological dose to less than 0.5-mrem/hr during operation. The main source of the biological dose is the photons and the neutrons generated by interactions of leaked electrons from the electron gun and accelerator sections with the surrounding concrete and accelerator materials. The Monte Carlo code MCNPX serves as the calculation tool for the shield design, due to its capability to transport electrons, photons, and neutrons coupled problems. The direct photon dose can be tallied by MCNPX calculation, starting with the leaked electrons. However, it is difficult to accurately tally the neutron dose directly from the leaked electrons. The neutron yield per electron from the interactions with the surrounding components is less than 0.01 neutron per electron. This causes difficulties for Monte Carlo analyses and consumes tremendous computation time for tallying with acceptable statistics the neutron dose outside the shield boundary. To avoid these difficulties, the SOURCE and TALLYX user subroutines of MCNPX were developed for the study. The generated neutrons are banked, together with all related parameters, for a subsequent MCNPX calculation to obtain the neutron and secondary photon doses. The weight windows variance reduction technique is utilized for both neutron and photon dose calculations. Two shielding materials, i.e., heavy concrete and ordinary concrete, were considered for the shield design. The main goal is to maintain the total

  14. Accelerator-based neutron source for the neutron-capture and fast neutron therapy at hospital

    NASA Astrophysics Data System (ADS)

    Bayanov, B. F.; Belov, V. P.; Bender, E. D.; Bokhovko, M. V.; Dimov, G. I.; Kononov, V. N.; Kononov, O. E.; Kuksanov, N. K.; Palchikov, V. E.; Pivovarov, V. A.; Salimov, R. A.; Silvestrov, G. I.; Skrinsky, A. N.; Soloviov, N. A.; Taskaev, S. Yu.

    The proton accelerator complex for neutron production in lithium target discussed, which can operate in two modes. The first provides a neutron beam kinematically collimated with good forward direction in 25° and average energy of 30 keV, directly applicable for neutron-capture therapy with high efficiency of proton beam use. The proton energy in this mode is 1.883-1.890 MeV that is near the threshold of the 7Li( p, n) 7Be reaction. In the second mode, at proton energy of 2.5 MeV, the complex-produced neutron beam with maximum energy board of 790 keV which can be used directly for fast neutron therapy and for neutron-capture therapy after moderation. The project of such a neutron source is based on the 2.5 MeV original electrostatic accelerator tandem with vacuum insulation developed at BINP which is supplied with a high-voltage rectifier. The rectifier is produced in BINP as a part of ELV-type industrial accelerator. Design features of the tandem determining its high reliability in operation with a high-current (up to 40 mA) H - ion beam are discussed. They are: the absence of ceramic accelerator columns around the beam passage region, good conditions for pumping out of charge-exchange gaseous target region, strong focusing optics and high acceleration rate minimizing the space charge effects. The possibility of stabilization of protons energy with an accuracy level of 0.1% necessary for operation in the near threshold region is considered. The design description of H - continuous ion source with a current of 40 mA is also performed. To operate with a 100 kW proton beam it is proposed to use liquid-lithium targets. A thin lithium layer on the surface of a tungsten disk cooled intensively by a liquid metal heat carrier is proposed for use in case of the vertical beam, and a flat liquid lithium jet flowing through the narrow nozzle - for the horizontal beam.

  15. COMMISSIONING OF THE SPALLATION NEUTRON SOURCE ACCELERATOR SYSTEMS

    SciTech Connect

    Plum, Michael A

    2007-01-01

    The Spallation Neutron Source accelerator complex consists of a 2.5 MeV H- front-end injector system, a 186 MeV normal-conducting linear accelerator, a 1 GeV superconducting linear accelerator, an accumulator ring, and associated beam transport lines. The linac was commissioned in five discrete runs, starting in 2002 and completed in 2005. The accumulator ring and associated beam transport lines were commissioned in two runs from January to April 2006. With the completed commissioning of the SNS accelerator, the facility has begun initial low-power operations. In the course of beam commissioning, most beam performance parameters and beam intensity goals have been achieved at low duty factor. A number of beam dynamics measurements have been performed, including emittance evolution, transverse coupling in the ring, beam instability thresholds, and beam distributions on the target. The commissioning results, achieved beam performance and initial operating experience of the SNS will be discussed

  16. A high power accelerator driver system for spallation neutron sources

    SciTech Connect

    Jason, A.; Blind, B.; Channell, P.

    1996-07-01

    This is the final report of a two-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). For several years, the Los Alamos Meson Physics Facility (LAMPF) and the Proton Storage Ring (PSR) have provided a successful driver for the nearly 100-kW Los Alamos Neutron Scattering Center (LANSCE) source. The authors have studied an upgrade to this system. The goal of this effort was to establish a credible design for the accelerator driver of a next-generation source providing 1-MW of beam power. They have explored a limited subset of the possible approaches to a driver and have considered only the low 1-MW beam power. The next-generation source must utilize the optimum technology and may require larger neutron intensities than they now envision.

  17. Laser Acceleration of Ultrashort Ion Bunches and Femtosecond Neutron Sources

    SciTech Connect

    Macchi, A.; Cattani, F.; Liseykina, T. V.; Cornolti, F.

    2006-04-07

    We have theoretically investigated the acceleration of ions in the interaction of high intensity, circularly polarized laser pulses with overdense plasmas. By using 1D and 2D particle-in-cell (PIC) simulations we find that high-density, short duration ion bunches moving into the plasma are promptly generated at the laser-plasma interaction surface. This regime is qualitatively different from ion acceleration regimes driven by fast electrons, such as sheath acceleration at the back of the target or shock acceleration at the front, which occur for linear polarization. A simple analytical model accounts for the numerical observations and provides scaling laws for the ion bunch velocity and generation time as a function of pulse intensity and plasma density. The present mechanism based on circular polarization of the laser pulse leads to moderate ion energies (in the 100 keV-1 MeV range) but very high ion densities and low beam divergence. These ion bunches might be of interest for problems of compression and acceleration of high-density matter by short pulses as well as for the development of compact neutron sources. We analyzed a scheme based on two-side irradiation of a thin foil deuterated target, where two colliding ion bunches are produced leading to an ultrashort neutron burst. We evaluated that, for intensities of a few 1019 W cm-2, more than 103 neutrons per Joule may be produced within a time shorter than one femtosecond. Another scheme based on a layered deuterium-tritium target is outlined.

  18. Beam intensity increases at the intense pulsed neutron source accelerator

    SciTech Connect

    Potts, C.; Brumwell, F.; Norem, J.; Rauchas, A.; Stipp, V.; Volk, G.

    1985-01-01

    The Intense Pulsed Neutron Source (IPNS) accelerator system has managed a 40% increase in time average beam current over the last two years. Currents of up to 15.6..mu..A (3.25 x 10/sup 12/ protons at 30 Hz) have been successfully accelerated and cleanly extracted. Our high current operation demands low loss beam handling to permit hands-on maintenance. Synchrotron beam handling efficiencies of 90% are routine. A new H/sup -/ ion source which was installed in March of 1983 offered the opportunity to get above 8 ..mu..A but an instability caused unacceptable losses when attempting to operate at 10 ..mu..A and above. Simple techniques to control the instabilities were introduced and have worked well. These techniques are discussed below. Other improvements in the regulation of various power supplies have provided greatly improved low energy orbit stability and contributed substantially to the increased beam current.

  19. Recent performance of the Intense Pulsed Neutron Source accelerator system

    SciTech Connect

    Potts, C.; Brumwell, F.; Rauchas, A.; Stipp, V.; Volk, G.; Donley, L.

    1987-03-01

    The Intense Pulsed Neutron Source (IPNS) accelerator system has now been in operation as part of a national user program for over five years. During that period steady progress has been made in both beam intensity and reliability. Almost 1.8 billion pulses totaling 4 x 10/sup 21/ protons have now been delivered to the spallation neutron target. Recent weekly average currents have reached 15 ..mu..A (3.2 x 10/sup 12/ protons per pulse, 30 pulses per second) and short-term peaks of almost 17 ..mu..A have been reached. In fact, the average current for the last two years is up 31% over the average for the first three years of operation.

  20. Optimization of an accelerator-based epithermal neutron source for neutron capture therapy

    SciTech Connect

    Kononov, O.E.; Kononov, V.N.; Bokhovko, M.V.; Korobeynikov, V.V.; Soloviev, A.N.; Chu, W.T.

    2004-02-20

    A modeling investigation was performed to choose moderator material and size for creating optimal epithermal neutron beams for BNCT based on a proton accelerator and the 7Li(p,n)7Be reaction as a neutrons source. An optimal configuration is suggested for the beam shaping assembly made from polytetrafluoroethylene and magnesium fluorine. Results of calculation were experimentally tested and are in good agreement with measurements.

  1. Conceptual design of an RFQ accelerator-based neutron source for boron neutron-capture therapy

    SciTech Connect

    Wangler, T.P.; Stovall, J.E.; Bhatia, T.S.; Wang, C.K.; Blue, T.E.; Gahbauer, R.A.

    1989-01-01

    We present a conceptual design of a low-energy neutron generator for treatment of brain tumors by boron neutron capture theory (BNCT). The concept is based on a 2.5-MeV proton beam from a radio-frequency quadrupole (RFQ) linac, and the neutrons are produced by the /sup 7/Li(p,n)/sup 7/Be reaction. A liquid lithium target and modulator assembly are designed to provide a high flux of epithermal neutrons. The patient is administered a tumor-specific /sup 10/Be-enriched compound and is irradiated by the neutrons to create a highly localized dose from the reaction /sup 10/B(n,..cap alpha..)/sup 7/Li. An RFQ accelerator-based neutron source for BNCT is compact, which makes it practical to site the facility within a hospital. 11 refs., 5 figs., 1 tab.

  2. Accelerator-based neutron source for boron neutron capture therapy (BNCT) and method

    DOEpatents

    Yoon, Woo Y.; Jones, James L.; Nigg, David W.; Harker, Yale D.

    1999-01-01

    A source for boron neutron capture therapy (BNCT) comprises a body of photoneutron emitter that includes heavy water and is closely surrounded in heat-imparting relationship by target material; one or more electron linear accelerators for supplying electron radiation having energy of substantially 2 to 10 MeV and for impinging such radiation on the target material, whereby photoneutrons are produced and heat is absorbed from the target material by the body of photoneutron emitter. The heavy water is circulated through a cooling arrangement to remove heat. A tank, desirably cylindrical or spherical, contains the heavy water, and a desired number of the electron accelerators circumferentially surround the tank and the target material as preferably made up of thin plates of metallic tungsten. Neutrons generated within the tank are passed through a surrounding region containing neutron filtering and moderating materials and through neutron delimiting structure to produce a beam or beams of epithermal neutrons normally having a minimum flux intensity level of 1.0.times.10.sup.9 neutrons per square centimeter per second. Such beam or beams of epithermal neutrons are passed through gamma ray attenuating material to provide the required epithermal neutrons for BNCT use.

  3. Accelerator-based neutron source for boron neutron capture therapy (BNCT) and method

    DOEpatents

    Yoon, W.Y.; Jones, J.L.; Nigg, D.W.; Harker, Y.D.

    1999-05-11

    A source for boron neutron capture therapy (BNCT) comprises a body of photoneutron emitter that includes heavy water and is closely surrounded in heat-imparting relationship by target material; one or more electron linear accelerators for supplying electron radiation having energy of substantially 2 to 10 MeV and for impinging such radiation on the target material, whereby photoneutrons are produced and heat is absorbed from the target material by the body of photoneutron emitter. The heavy water is circulated through a cooling arrangement to remove heat. A tank, desirably cylindrical or spherical, contains the heavy water, and a desired number of the electron accelerators circumferentially surround the tank and the target material as preferably made up of thin plates of metallic tungsten. Neutrons generated within the tank are passed through a surrounding region containing neutron filtering and moderating materials and through neutron delimiting structure to produce a beam or beams of epithermal neutrons normally having a minimum flux intensity level of 1.0{times}10{sup 9} neutrons per square centimeter per second. Such beam or beams of epithermal neutrons are passed through gamma ray attenuating material to provide the required epithermal neutrons for BNCT use. 3 figs.

  4. A neutron producing target for BINP accelerator-based neutron source.

    PubMed

    Bayanov, B; Kashaeva, E; Makarov, A; Malyshkin, G; Samarin, S; Taskaev, S

    2009-07-01

    An innovative accelerator-based neutron source for BNCT has just started operation at the Budker Institute of Nuclear Physics, Novosibirsk. One of the main elements of the facility is a lithium target producing neutrons via the threshold (7)Li(p,n)(7)Be reaction at 25 kW proton beam with energies of 1.915 MeV or 2.5 MeV. The design of an optimal target and results of the investigation of radiation blistering of the lithium layer were presented at previous NCT Congresses. During the last two years the neutron target has been manufactured, assembled and placed in the facility. Optimization of the target is carried out with the Monte Carlo simulation code MCNP. In this article, the design of the target is discussed, results of all previous investigations are summarized, results of target testing and neutron generation are described, and results of simulation of neutron spectra are presented. PMID:19376729

  5. Neutron sources in a 24-MV medical linear accelerator.

    PubMed

    LaRiviere, P D

    1985-01-01

    During the assembly of the prototype Clinac 2500, a unique opportunity arose to measure the cumulative total neutron yield of the machine as the major subassemblies were added, section by section. Differentiation of the results led to an inventory of the relative strength of the several neutron sources identified. The method utilized the fact that the scattered neutron fluence in a cavity in concrete is nearly uniform throughout the space and proportional to the fast neutron source strength. When normalized to the neutron output of the guide with bend magnet vacuum chamber, the relative neutron source strengths found were target, 1.9; primary collimator, 2.4; steel filter, 0.6; tungsten filter, 1.5; and jaw system, 0.8 open and approximately 2.0 closed. There is reasonable agreement between these measurements and published estimates of the yields from the major components of the treatment head. PMID:4079876

  6. Novel neutron sources at the Radiological Research Accelerator Facility.

    PubMed

    Xu, Yanping; Garty, Guy; Marino, Stephen A; Massey, Thomas N; Randers-Pehrson, Gerhard; Johnson, Gary W; Brenner, David J

    2012-03-16

    Since the 1960s, the Radiological Research Accelerator Facility (RARAF) has been providing researchers in biology, chemistry and physics with advanced irradiation techniques, using charged particles, photons and neutrons.We are currently developing a unique facility at RARAF, to simulate neutron spectra from an improvised nuclear device (IND), based on calculations of the neutron spectrum at 1.5 km from the epicenter of the Hiroshima atom bomb. This is significantly different from a standard fission spectrum, because the spectrum changes as the neutrons are transported through air, and is dominated by neutron energies between 0.05 and 8 MeV. This facility will be based on a mixed proton/deuteron beam impinging on a thick beryllium target.A second, novel facility under development is our new neutron microbeam. The neutron microbeam will, for the first time, provide a kinematically collimated neutron beam, 10-20 micron in diameter. This facility is based on a Proton Microbeam, impinging on a thin lithium target near the threshold of the (7)Li(p,n)(7)Be reaction. This novel neutron microbeam will enable studies of neutron damage to small targets, such as single cells, individual organs within small animals or microelectronic components. PMID:22545061

  7. Novel neutron sources at the Radiological Research Accelerator Facility

    DOE PAGESBeta

    Xu, Yanping; Garty, G.; Marino, S. A.; Massey, Thomas Neal; Johnson, G. W.; Randers-Pehrson, Gerhard; Brenner, D. J.

    2012-03-16

    Since the 1960s, the Radiological Research Accelerator Facility (RARAF) has been providing researchers in biology, chemistry and physics with advanced irradiation techniques, using charged particles, photons and neutrons. We are currently developing a unique facility at RARAF, to simulate neutron spectra from an improvised nuclear device (IND), based on calculations of the neutron spectrum at 1.5 km from the epicenter of the Hiroshima atom bomb. This is significantly different from a standard fission spectrum, because the spectrum changes as the neutrons are transported through air, and is dominated by neutron energies between 0.05 and 8 MeV. This facility will bemore » based on a mixed proton/deuteron beam impinging on a thick beryllium target. A second, novel facility under development is our new neutron microbeam. The neutron microbeam will, for the first time, provide a kinematically collimated neutron beam, 10-20 micron in diameter. This facility is based on a proton microbeam, impinging on a thin lithium target near the threshold of the Li-7(p,n)Be-7 reaction. Lastly, this novel neutron microbeam will enable studies of neutron damage to small targets, such as single cells, individual organs within small animals or microelectronic components.« less

  8. Novel neutron sources at the Radiological Research Accelerator Facility

    PubMed Central

    Xu, Yanping; Garty, Guy; Marino, Stephen A.; Massey, Thomas N.; Randers-Pehrson, Gerhard; Johnson, Gary W.; Brenner, David J.

    2012-01-01

    Since the 1960s, the Radiological Research Accelerator Facility (RARAF) has been providing researchers in biology, chemistry and physics with advanced irradiation techniques, using charged particles, photons and neutrons. We are currently developing a unique facility at RARAF, to simulate neutron spectra from an improvised nuclear device (IND), based on calculations of the neutron spectrum at 1.5 km from the epicenter of the Hiroshima atom bomb. This is significantly different from a standard fission spectrum, because the spectrum changes as the neutrons are transported through air, and is dominated by neutron energies between 0.05 and 8 MeV. This facility will be based on a mixed proton/deuteron beam impinging on a thick beryllium target. A second, novel facility under development is our new neutron microbeam. The neutron microbeam will, for the first time, provide a kinematically collimated neutron beam, 10–20 micron in diameter. This facility is based on a Proton Microbeam, impinging on a thin lithium target near the threshold of the 7Li(p,n)7Be reaction. This novel neutron microbeam will enable studies of neutron damage to small targets, such as single cells, individual organs within small animals or microelectronic components. PMID:22545061

  9. Novel neutron sources at the Radiological Research Accelerator Facility

    SciTech Connect

    Xu, Yanping; Garty, G.; Marino, S. A.; Massey, Thomas Neal; Johnson, G. W.; Randers-Pehrson, Gerhard; Brenner, D. J.

    2012-03-16

    Since the 1960s, the Radiological Research Accelerator Facility (RARAF) has been providing researchers in biology, chemistry and physics with advanced irradiation techniques, using charged particles, photons and neutrons. We are currently developing a unique facility at RARAF, to simulate neutron spectra from an improvised nuclear device (IND), based on calculations of the neutron spectrum at 1.5 km from the epicenter of the Hiroshima atom bomb. This is significantly different from a standard fission spectrum, because the spectrum changes as the neutrons are transported through air, and is dominated by neutron energies between 0.05 and 8 MeV. This facility will be based on a mixed proton/deuteron beam impinging on a thick beryllium target. A second, novel facility under development is our new neutron microbeam. The neutron microbeam will, for the first time, provide a kinematically collimated neutron beam, 10-20 micron in diameter. This facility is based on a proton microbeam, impinging on a thin lithium target near the threshold of the Li-7(p,n)Be-7 reaction. Lastly, this novel neutron microbeam will enable studies of neutron damage to small targets, such as single cells, individual organs within small animals or microelectronic components.

  10. Novel neutron sources at the Radiological Research Accelerator Facility

    NASA Astrophysics Data System (ADS)

    Xu, Y.; Garty, G.; Marino, S. A.; Massey, T. N.; Randers-Pehrson, G.; Johnson, G. W.; Brenner, D. J.

    2012-03-01

    Since the 1960s, the Radiological Research Accelerator Facility (RARAF) has been providing researchers in biology, chemistry and physics with advanced irradiation techniques, using charged particles, photons and neutrons. We are currently developing a unique facility at RARAF, to simulate neutron spectra from an improvised nuclear device (IND), based on calculations of the neutron spectrum at 1.5 km from the epicenter of the Hiroshima atom bomb. This is significantly different from a standard fission spectrum, because the spectrum changes as the neutrons are transported through air, and is dominated by neutron energies between 0.05 and 8 MeV. This facility will be based on a mixed proton/deuteron beam impinging on a thick beryllium target. A second, novel facility under development is our new neutron microbeam. The neutron microbeam will, for the first time, provide a kinematically collimated neutron beam, 10-20 micron in diameter. This facility is based on a proton microbeam, impinging on a thin lithium target near the threshold of the 7Li(p,n)7Be reaction. This novel neutron microbeam will enable studies of neutron damage to small targets, such as single cells, individual organs within small animals or microelectronic components.

  11. Lithium target for accelerator based BNCT neutron source: Influence by the proton irradiation on lithium

    NASA Astrophysics Data System (ADS)

    Fujii, R.; Imahori, Y.; Nakakmura, M.; Takada, M.; Kamada, S.; Hamano, T.; Hoshi, M.; Sato, H.; Itami, J.; Abe, Y.; Fuse, M.

    2012-12-01

    The neutron source for Boron Neutron Capture Therapy (BNCT) is in the transition stage from nuclear reactor to accelerator based neutron source. Generation of low energy neutron can be achieved by 7Li (p, n) 7Be reaction using accelerator based neutron source. Development of small-scale and safe neutron source is within reach. The melting point of lithium that is used for the target is low, and durability is questioned for an extended use at a high current proton beam. In order to test its durability, we have irradiated lithium with proton beam at the same level as the actual current density, and found no deterioration after 3 hours of continuous irradiation. As a result, it is suggested that lithium target can withstand proton irradiation at high current, confirming suitability as accelerator based neutron source for BNCT.

  12. Ion Acceleration by Magnetic Pinch Instabilities- Powerful Neutron Sources

    NASA Astrophysics Data System (ADS)

    Hayes, Anna; Li, Hui

    2014-10-01

    Since the 1950s pinch discharges with deuterium gas have been known to produce large neutron bursts. During these early quests for laboratory fusion it was initially believed that the heat produced in the pinch led to sufficently high temperatures that these neutrons resulted from thermonuclear (TN) burn. However, a series of careful measurements led by Stirling Colgate was carried out to show that these neutrons did not result form TN burn. Rather, they resulted from an m = 0 sausage mode instability that accelerated the ions, causing beam-target interactions. Today, this same mechanism is used in dense plasma focus machines to generate intense neutron pulses for neutron activation experiments. One such experiment, to test the citicality of aging plutonium, is currently being planned at the Nevada Test Site. Helping to characterize the neutrons from the dense palsma focus to be used in this large experiment was the last applied physics project that Stirling work on. In this talk we will summarize the physics issues involved both in the original discovery in the 1950s and in today's experiments.

  13. Neutron source in the MCNPX shielding calculating for electron accelerator driven facility

    SciTech Connect

    Zhong, Z.; Gohar, Y.

    2012-07-01

    Argonne National Laboratory (ANL) of USA and Kharkov Inst. of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of an experimental neutron source facility. It is an accelerator driven system (ADS) utilizing a subcritical assembly driven by electron accelerator. The facility will be utilized for performing basic and applied nuclear researches, producing medical isotopes, and training young nuclear specialists. Monte Carlo code MCNPX has been utilized as a design tool due to its capability to transport electrons, photons, and neutrons at high energies. However the facility shielding calculations with MCNPX need enormous computational resources and the small neutron yield per electron makes sampling difficulty for the Monte Carlo calculations. A method, based on generating and utilizing neutron source file, was proposed and tested. This method reduces significantly the required computer resources and improves the statistics of the calculated neutron dose outside the shield boundary. However the statistical errors introduced by generating the neutron source were not directly represented in the results, questioning the validity of this methodology, because an insufficiently sampled neutron source can cause error on the calculated neutron dose. This paper presents a procedure for the validation of the generated neutron source file. The impact of neutron source statistic on the neutron dose is examined by calculating the neutron dose as a function of the number of electron particles used for generating the neutron source files. When the value of the calculated neutron dose converges, it means the neutron source has scored sufficient records and statistic does not have apparent impact on the calculated neutron dose. In this way, the validity of neutron source and the shield analyses could be verified. (authors)

  14. Brighter H/sup -/ source for the intense pulsed neutron source accelerator system

    SciTech Connect

    Stipp, V.; DeWitt, A.; Madsen, J.

    1983-01-01

    Further increases in the beam intensity of the Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory required the replacement of the H/sup -/ source with a higher current source. A magnetron ion source of Fermi National Accelerator Laboratory (FNAL) design was adapted with a grooved cathode to provide a stable 40 to 50 mA of beam operating at 30 Hz for up to a 90 ..mu..s pulse duration. Problems of space charge blowup due to the lack of neutralization of the H/sup -/ beam were solved by injecting additional gs into the 20 keV transport system. The source has recently been installed in the machine and the available input to the accelerator has more than doubled.

  15. An accelerator-based epithermal photoneutron source for boron neutron capture therapy

    SciTech Connect

    Mitchell, H.E.

    1996-04-01

    Boron neutron capture therapy is an experimental binary cancer radiotherapy modality in which a boronated pharmaceutical that preferentially accumulates in malignant tissue is first administered, followed by exposing the tissue in the treatment volume to a thermal neutron field. Current usable beams are reactor-based but a viable alternative is the production of an epithermal neutron beam from an accelerator. Current literature cites various proposed accelerator-based designs, most of which are based on proton beams with beryllium or lithium targets. This dissertation examines the efficacy of a novel approach to BNCT treatments that incorporates an electron linear accelerator in the production of a photoneutron source. This source may help to resolve some of the present concerns associated with accelerator sources, including that of target cooling. The photoneutron production process is discussed as a possible alternate source of neutrons for eventual BNCT treatments for cancer. A conceptual design to produce epithermal photoneutrons by high photons (due to bremsstrahlung) impinging on deuterium targets is presented along with computational and experimental neutron production data. A clinically acceptable filtered epithermal neutron flux on the order of 10{sup 7} neutrons per second per milliampere of electron current is shown to be obtainable. Additionally, the neutron beam is modified and characterized for BNCT applications by employing two unique moderating materials (an Al/AlF{sub 3} composite and a stacked Al/Teflon design) at various incident electron energies.

  16. Optimizing Laser-accelerated Ion Beams for a Collimated Neutron Source

    SciTech Connect

    C.L. Ellison and J. Fuchs

    2010-09-23

    High-flux neutrons for imaging and materials analysis applications have typically been provided by accelerator- and reactor-based neutron sources. A novel approach is to use ultraintense (>1018W/cm2) lasers to generate picosecond, collimated neutrons from a dual target configuration. In this article, the production capabilities of present and upcoming laser facilities are estimated while independently maximizing neutron yields and minimizing beam divergence. A Monte-Carlo code calculates angular and energy distributions of neutrons generated by D-D fusion events occurring within a deuterated target for a given incident beam of D+ ions. Tailoring of the incident distribution via laser parameters and microlens focusing modifies the emerging neutrons. Projected neutron yields and distributions are compared to conventional sources, yielding comparable on-target fluxes per discharge, shorter time resolution, larger neutron energies and greater collimation.

  17. Characterisation of an accelerator-based neutron source for BNCT versus beam energy

    NASA Astrophysics Data System (ADS)

    Agosteo, S.; Curzio, G.; d'Errico, F.; Nath, R.; Tinti, R.

    2002-01-01

    Neutron capture in 10B produces energetic alpha particles that have a high linear energy transfer in tissue. This results in higher cell killing and a higher relative biological effectiveness compared to photons. Using suitably designed boron compounds which preferentially localize in cancerous cells instead of healthy tissues, boron neutron capture therapy (BNCT) has the potential of providing a higher tumor cure rate within minimal toxicity to normal tissues. This clinical approach requires a thermal neutron source, generally a nuclear reactor, with a fluence rate sufficient to deliver tumorcidal doses within a reasonable treatment time (minutes). Thermal neutrons do not penetrate deeply in tissue, therefore BNCT is limited to lesions which are either superficial or otherwise accessible. In this work, we investigate the feasibility of an accelerator-based thermal neutron source for the BNCT of skin melanomas. The source was designed via MCNP Monte Carlo simulations of the thermalization of a fast neutron beam, generated by 7 MeV deuterons impinging on a thick target of beryllium. The neutron field was characterized at several deuteron energies (3.0-6.5 MeV) in an experimental structure installed at the Van De Graaff accelerator of the Laboratori Nazionali di Legnaro, in Italy. Thermal and epithermal neutron fluences were measured with activation techniques and fast neutron spectra were determined with superheated drop detectors (SDD). These neutron spectrometry and dosimetry studies indicated that the fast neutron dose is unacceptably high in the current design. Modifications to the current design to overcome this problem are presented.

  18. The Need for a Neutron Source at the Rare Isotope Accelerator

    SciTech Connect

    Ahle, L E; Rusnak, B; Roberts, K E; Roeben, M D; Hausmann, M; Reifarth, R; Vieira, D

    2005-05-13

    An intense neutron source facility with radiochemical processing capability is necessary at the Rare Isotope Accelerator to fully realize its potential benefit to stockpile stewardship and astrophysics. While many of the important physics missions of RIA can be addressed with radioactive ion beams, direct neutron cross-section measurements of interest to stockpile stewardship and astrophysics cannot because one cannot make a neutron target. Thus, one must collect a sufficient amount of the appropriate short-lived isotope, quickly chemically process the material into a target, and promptly radiate the sample with an intense ''beam'' of neutrons. The unprecedented production rates expected at RIA enables many of these direct neutron cross-section measurements, but only if the proper infrastructure is in place. This document not only describes the major piece of this required infrastructure, a neutron source facility with radiochemical processing capabilities, but also the motivation for measuring such direct neutron cross-sections.

  19. Characterization of an accelerator neutron source based on the Be(d,n) reaction

    SciTech Connect

    Meadows, J.W.; Smith, D.L.

    1992-07-01

    Small accelerator neutron sources offer considerable potential for applied neutron radiography applications. Among the desirable features are relatively low costs, limited operating hazards, opportunities for tailoring primary neutron spectra, compactness and portability, and modest licensing requirements (compared to fission reactors). However, exploitation of this potential has been somewhat limited, in part, by incomplete knowledge of the primary-neutron yields and energy spectra from the favorable source reactions. This work describes an extensive experimental determination of zero-degree neutron yields and energy spectra from the {sup 9}Be(d,n) {sup 10}B source reaction, for incident deuterons of 2.6 to 7.0 MeV on a thick beryllium metal target. This information was acquired by means of time-of-flight measurements that were conducted with a calibrated uranium fission detector. Tables and plots of neutron-producing reaction data are presented. This information provides input which will be essential for applications involving the primary spectrum as well as for the design of neutron moderators and for calculation of thermal-neutron yield factors. Such analyses will be prerequisites in assessing the suitability of this source for various possible neutron radiography applications and, also, for assisting in the design of appropriate detectors to be used in neutron imaging devices.

  20. Characterization of an accelerator neutron source based on the Be(d,n) reaction

    SciTech Connect

    Meadows, J.W.; Smith, D.L.

    1992-01-01

    Small accelerator neutron sources offer considerable potential for applied neutron radiography applications. Among the desirable features are relatively low costs, limited operating hazards, opportunities for tailoring primary neutron spectra, compactness and portability, and modest licensing requirements (compared to fission reactors). However, exploitation of this potential has been somewhat limited, in part, by incomplete knowledge of the primary-neutron yields and energy spectra from the favorable source reactions. This work describes an extensive experimental determination of zero-degree neutron yields and energy spectra from the {sup 9}Be(d,n) {sup 10}B source reaction, for incident deuterons of 2.6 to 7.0 MeV on a thick beryllium metal target. This information was acquired by means of time-of-flight measurements that were conducted with a calibrated uranium fission detector. Tables and plots of neutron-producing reaction data are presented. This information provides input which will be essential for applications involving the primary spectrum as well as for the design of neutron moderators and for calculation of thermal-neutron yield factors. Such analyses will be prerequisites in assessing the suitability of this source for various possible neutron radiography applications and, also, for assisting in the design of appropriate detectors to be used in neutron imaging devices.

  1. Study of an External Neutron Source for an Accelerator-Driven System using the PHITS Code

    SciTech Connect

    Sugawara, Takanori; Iwasaki, Tomohiko; Chiba, Takashi

    2005-05-24

    A code system for the Accelerator Driven System (ADS) has been under development for analyzing dynamic behaviors of a subcritical core coupled with an accelerator. This code system named DSE (Dynamics calculation code system for a Subcritical system with an External neutron source) consists of an accelerator part and a reactor part. The accelerator part employs a database, which is calculated by using PHITS, for investigating the effect related to the accelerator such as the changes of beam energy, beam diameter, void generation, and target level. This analysis method using the database may introduce some errors into dynamics calculations since the neutron source data derived from the database has some errors in fitting or interpolating procedures. In this study, the effects of various events are investigated to confirm that the method based on the database is appropriate.

  2. Accelerator based epithermal neutron source for neutron capture therapy. Annual report, [October 1990--April 1991

    SciTech Connect

    Brugger, R.; Kunze, J.

    1991-05-01

    Several investigators have suggested that a charged particle accelerator with light element reactions might be able to produce enough epithermal neutrons to be useful in Neutron Capture Therapy. The reaction choice so far has been the Li(p,n) reaction with protons up to 2.5 MeV. A moderator around the target would reduce the faster neutrons down to the epithermal energy region. The goals of the present research are: identify better reactions; improve the moderators; and find better combinations of 1 and 2. The target is to achieve, at the patient location, an epithermal neutron current of greater than 10{sup 9}n/cm{sup 2}sec, with a dose to tissue from the neutrons alone of less than 10{sup {minus}10} rads/n and a dose from the gamma rays in the beam of less than 10{sup {minus}10} rads/n.

  3. Shielding design of a treatment room for an accelerator-based neutron source for BNCT

    SciTech Connect

    Evans, J.F.; Blue, T.E.

    1995-12-31

    For several years, research has been ongoing in the Ohio State University (OSU) Nuclear Engineering Program toward the development of an accelerator-based irradiation facility (ANIF) neutron source for boron neutron capture therapy (BNCT). The ANIF, which is planned to be built in a hospital, has been conceptually designed and analyzed. After Qu, an OSU researcher, determined that the shielding design of a 6-MV X-ray treatment room was inadequate to protect personnel from an accelerator neutron source operating at 30 mA, we decided to analyze and determine the shielding requirements of a treatment room for an ANIF. We determined the amount of shielding that would be sufficient to protect facility personnel from excessive radiation exposure caused by operation of the accelerator at 30 mA.

  4. Microwave Ion Source and Beam Injection for an Accelerator-drivenNeutron Source

    SciTech Connect

    Vainionpaa, J.H.; Gough, R.; Hoff, M.; Kwan, J.W.; Ludewigt,B.A.; Regis, M.J.; Wallig, J.G.; Wells, R.

    2007-02-15

    An over-dense microwave driven ion source capable ofproducing deuterium (or hydrogen) beams at 100-200 mA/cm2 and with atomicfraction>90 percent was designed and tested with an electrostaticlow energy beam transport section (LEBT). This ion source wasincorporatedinto the design of an Accelerator Driven Neutron Source(ADNS). The other key components in the ADNS include a 6 MeV RFQaccelerator, a beam bending and scanning system, and a deuterium gastarget. In this design a 40 mA D+ beam is produced from a 6 mm diameteraperture using a 60 kV extraction voltage. The LEBT section consists of 5electrodes arranged to form 2 Einzel lenses that focus the beam into theRFQ entrance. To create the ECR condition, 2 induction coils are used tocreate ~; 875 Gauss on axis inside the source chamber. To prevent HVbreakdown in the LEBT a magnetic field clamp is necessary to minimize thefield in this region. Matching of the microwave power from the waveguideto the plasma is done by an autotuner. We observed significantimprovement of the beam quality after installing a boron nitride linerinside the ion source. The measured emittance data are compared withPBGUNS simulations.

  5. Systematic neutron guide misalignment for an accelerator-driven spallation neutron source

    NASA Astrophysics Data System (ADS)

    Zendler, C.; Bentley, P. M.

    2016-08-01

    The European Spallation Source (ESS) is a long pulse spallation neutron source that is currently under construction in Lund, Sweden. A considerable fraction of the 22 planned instruments extend as far as 75-150 m from the source. In such long beam lines, misalignment between neutron guide segments can decrease the neutron transmission significantly. In addition to a random misalignment from installation tolerances, the ground on which ESS is built can be expected to sink with time, and thus shift the neutron guide segments further away from the ideal alignment axis in a systematic way. These systematic errors are correlated to the ground structure, position of buildings and shielding installation. Since the largest deformation is expected close to the target, even short instruments might be noticeably affected. In this study, the effect of this systematic misalignment on short and long ESS beam lines is analyzed, and a possible mitigation by overillumination of subsequent guide sections investigated.

  6. ESS-Bilbao light-ion linear accelerator and neutron source: design and applications

    NASA Astrophysics Data System (ADS)

    Abad, E.; Arredondo, I.; Badillo, I.; Belver, D.; Bermejo, F. J.; Bustinduy, I.; Cano, D.; Cortazar, D.; de Cos, D.; Djekic, S.; Domingo, S.; Echevarria, P.; Eguiraun, M.; Etxebarria, V.; Fernandez, D.; Fernandez, F. J.; Feuchtwanger, J.; Garmendia, N.; Harper, G.; Hassanzadegan, H.; Jugo, J.; Legarda, F.; Magan, M.; Martinez, R.; Megia, A.; Muguira, L.; Mujika, G.; Muñoz, J. L.; Ortega, A.; Ortega, J.; Perlado, M.; Portilla, J.; Rueda, I.; Sordo, F.; Toyos, V.; Vizcaino, A.

    2011-10-01

    The baseline design for the ESS-Bilbao light-ion linear accelerator and neutron source has been completed and the normal conducting section of the linac is at present under construction. The machine has been designed to be compliant with ESS specifications following the international guidelines of such project as described in Ref. [1]. The new accelerator facility in Bilbao will serve as a base for support of activities on accelerator physics carried out in Spain and southern Europe in the frame of different ongoing international collaborations. Also, a number of applications have been envisaged in the new Bilbao facility for the outgoing light ion beams as well as from fast neutrons produced by low-energy neutron-capture targets, which are briefly described.

  7. High-energy in-beam neutron measurements of metal-based shielding for accelerator-driven spallation neutron sources

    NASA Astrophysics Data System (ADS)

    DiJulio, D. D.; Cooper-Jensen, C. P.; Björgvinsdóttir, H.; Kokai, Z.; Bentley, P. M.

    2016-05-01

    Metal-based shielding plays an important role in the attenuation of harmful and unwanted radiation at an accelerator-driven spallation neutron source. At the European Spallation Source, currently under construction in Lund, Sweden, metal-based materials are planned to be used extensively as neutron guide substrates in addition to other shielding structures around neutron guides. The usage of metal-based materials in the vicinity of neutron guides however requires careful consideration in order to minimize potential background effects in a neutron instrument at the facility. Therefore, we have carried out a combined study involving high-energy neutron measurements and Monte Carlo simulations of metal-based shielding, both to validate the simulation methodology and also to investigate the benefits and drawbacks of different metal-based solutions. The measurements were carried out at The Svedberg Laboratory in Uppsala, Sweden, using a 174.1 MeV neutron beam and various thicknesses of aluminum-, iron-, and copper-based shielding blocks. The results were compared to geant4 simulations and revealed excellent agreement. Our combined study highlights the particular situations where one type of metal-based solution may be preferred over another.

  8. Additive effect of BPA and Gd-DTPA for application in accelerator-based neutron source.

    PubMed

    Yoshida, F; Yamamoto, T; Nakai, K; Zaboronok, A; Matsumura, A

    2015-12-01

    Because of its fast metabolism gadolinium as a commercial drug was not considered to be suitable for neutron capture therapy. We studied additive effect of gadolinium and boron co-administration using colony forming assay. As a result, the survival of tumor cells with additional 5 ppm of Gd-DTPA decreased to 1/10 compared to the cells with boron only. Using gadolinium to increase the effect of BNCT instead of additional X-ray irradiation might be beneficial, as such combination complies with the short-time irradiation regimen at the accelerator-based neutron source. PMID:26242560

  9. Benchmarking shielding simulations for an accelerator-driven spallation neutron source

    NASA Astrophysics Data System (ADS)

    Cherkashyna, Nataliia; DiJulio, Douglas D.; Panzner, Tobias; Rantsiou, Emmanouela; Filges, Uwe; Ehlers, Georg; Bentley, Phillip M.

    2015-08-01

    The shielding at an accelerator-driven spallation neutron facility plays a critical role in the performance of the neutron scattering instruments, the overall safety, and the total cost of the facility. Accurate simulation of shielding components is thus key for the design of upcoming facilities, such as the European Spallation Source (ESS), currently in construction in Lund, Sweden. In this paper, we present a comparative study between the measured and the simulated neutron background at the Swiss Spallation Neutron Source (SINQ), at the Paul Scherrer Institute (PSI), Villigen, Switzerland. The measurements were carried out at several positions along the SINQ monolith wall with the neutron dosimeter WENDI-2, which has a well-characterized response up to 5 GeV. The simulations were performed using the Monte-Carlo radiation transport code geant4, and include a complete transport from the proton beam to the measurement locations in a single calculation. An agreement between measurements and simulations is about a factor of 2 for the points where the measured radiation dose is above the background level, which is a satisfactory result for such simulations spanning many energy regimes, different physics processes and transport through several meters of shielding materials. The neutrons contributing to the radiation field emanating from the monolith were confirmed to originate from neutrons with energies above 1 MeV in the target region. The current work validates geant4 as being well suited for deep-shielding calculations at accelerator-based spallation sources. We also extrapolate what the simulated flux levels might imply for short (several tens of meters) instruments at ESS.

  10. Applications of compact accelerator-driven neutron sources: An updated assessment from the perspective of materials research in Italy

    SciTech Connect

    Andreani, C.; Anderson, I. S.; Carpenter, J. M.; Festa, G.; Gorini, G.; Loong, C. -K.; Senesi, R.

    2014-12-24

    In 2005 the International Atomic Energy Agency (IAEA) in Vienna published a report [1] on ‘Development Opportunities of Small and Medium Scale Accelerator Driven Neutron Sources’ which summarized the prospect of smaller sources in supporting the large spallation neutron sources for materials characterization and instrumentation, a theme advocated by Bauer, Clausen, Mank, and Mulhauser in previous publications [2-4]. In 2010 the Union for Compact Accelerator-driven Neutron Sources (UCANS) was established [5], galvanizing cross-disciplinary collaborations on new source and neutronics development and expanded applications based on both slow-neutron scattering and other neutron-matter interactions of neutron energies ranging from 10⁻⁶ to 10² MeV [6]. Here, we first cover the recent development of ongoing and prospective projects of compact accelerator-driven neutron sources (CANS) but concentrate on prospective accelerators currently proposed in Italy. Two active R&D topics, irradiation effects on electronics and cultural heritage studies, are chosen to illustrate the impact of state-of-the-art CANS on these programs with respect to the characteristics and complementarity of the accelerator and neutronics systems as well as instrumentation development.

  11. Applications of compact accelerator-driven neutron sources: An updated assessment from the perspective of materials research in Italy

    DOE PAGESBeta

    Andreani, C.; Anderson, I. S.; Carpenter, J. M.; Festa, G.; Gorini, G.; Loong, C. -K.; Senesi, R.

    2014-12-24

    In 2005 the International Atomic Energy Agency (IAEA) in Vienna published a report [1] on ‘Development Opportunities of Small and Medium Scale Accelerator Driven Neutron Sources’ which summarized the prospect of smaller sources in supporting the large spallation neutron sources for materials characterization and instrumentation, a theme advocated by Bauer, Clausen, Mank, and Mulhauser in previous publications [2-4]. In 2010 the Union for Compact Accelerator-driven Neutron Sources (UCANS) was established [5], galvanizing cross-disciplinary collaborations on new source and neutronics development and expanded applications based on both slow-neutron scattering and other neutron-matter interactions of neutron energies ranging from 10⁻⁶ to 10²more » MeV [6]. Here, we first cover the recent development of ongoing and prospective projects of compact accelerator-driven neutron sources (CANS) but concentrate on prospective accelerators currently proposed in Italy. Two active R&D topics, irradiation effects on electronics and cultural heritage studies, are chosen to illustrate the impact of state-of-the-art CANS on these programs with respect to the characteristics and complementarity of the accelerator and neutronics systems as well as instrumentation development.« less

  12. Laser ion acceleration and neutron source in short-pulse solid- nanoparticle interaction

    NASA Astrophysics Data System (ADS)

    Nishihara, K.; Watari, T.; Matsukado, K.; Sekine, T.; Takeuchi, Y.; Takagi, M.; Satoh, N.; Kawashima, T.; Kan, H.

    2016-03-01

    We propose both an efficient neutron source and an extremely high energy proton source using solid CD and CH nano-particles, respectively, irradiated by an intense laser light. With a use of 3-d PIC simulations, we obtain an optimum CD radius for a neutron source, 250 nm and required laser field of a=eE/mωc ≈ 2, which results in D-D reaction rate of <σv> = 2x10-16 cm3/s, corresponding to an effective deuteron temperature of 500 keV to 1MeV. Reduction of neutron yield by pre-expansion is discussed. In a range of a ≈100, laser radiation pressure surrounding the particles accelerates electrons in the forward direction. Protons following the electrons become directional high energy, for example, proton energy of 450 MeV is obtained within 130 fs in CH particle interaction with 700 nm in radius. More than 10% of total protons in CH-particles are accelerated forward. Proton energy continuously increases with time and with the increase of particle size and the direction is also collimated with time.

  13. Intense combined source of neutrons and photons for interrogation based on compact deuteron RF accelerator

    SciTech Connect

    Kurennoy, S. S.; Garnett, R. W.; Rybarcyk, L. J.

    2015-06-18

    Interrogation of special nuclear materials can benefit from mobile sources providing significant fluxes of neutrons (108/s at 2.5 MeV, 1010/s at 14.1 MeV) and of photons (>1012/s at 1-3 MeV). We propose a source that satisfies these requirements simultaneously plus also provides, via the reaction 11B(d,n)12C(γ15.1), a significant flux of 15-MeV photons, which are highly penetrating and optimal for inducing photo-fission in actinides. The source is based on a compact (< 5 m) deuteron RF accelerator that delivers an average current of a few mA of deuterons at 3-4 MeV to a boron target. The accelerator consists of a short RFQ followed by efficient inter-digital H-mode structures with permanent-magnet-quadrupole beam focusing [Kurennoy et al. (2012)], which suit perfectly for deuteron acceleration at low energies. Our estimates, based on recent measurements, indicate that the required fluxes of both neutrons and photons can be achieved at ~1 mA of 4-MeV deuterons. The goal of the proposed study is to confirm feasibility of the approach and develop requirements for future full system implementation.

  14. Intense combined source of neutrons and photons for interrogation based on compact deuteron RF accelerator

    DOE PAGESBeta

    Kurennoy, S. S.; Garnett, R. W.; Rybarcyk, L. J.

    2015-06-18

    Interrogation of special nuclear materials can benefit from mobile sources providing significant fluxes of neutrons (108/s at 2.5 MeV, 1010/s at 14.1 MeV) and of photons (>1012/s at 1-3 MeV). We propose a source that satisfies these requirements simultaneously plus also provides, via the reaction 11B(d,n)12C(γ15.1), a significant flux of 15-MeV photons, which are highly penetrating and optimal for inducing photo-fission in actinides. The source is based on a compact (< 5 m) deuteron RF accelerator that delivers an average current of a few mA of deuterons at 3-4 MeV to a boron target. The accelerator consists of a shortmore » RFQ followed by efficient inter-digital H-mode structures with permanent-magnet-quadrupole beam focusing [Kurennoy et al. (2012)], which suit perfectly for deuteron acceleration at low energies. Our estimates, based on recent measurements, indicate that the required fluxes of both neutrons and photons can be achieved at ~1 mA of 4-MeV deuterons. The goal of the proposed study is to confirm feasibility of the approach and develop requirements for future full system implementation.« less

  15. An epithermal neutron source for BNCT based on an ESQ-accelerator

    SciTech Connect

    Ludewigt, B.A.; Chu, W.T.; Donahue, R.J.; Kwan, J.; Phillips, T.L.; Reginato, L.L.; Wells, R.P.

    1997-07-01

    An accelerator-based BNCT facility is under development at the Lawrence Berkeley National Laboratory. Neutrons will be produced via the {sup 7}Li(p,n) reaction at proton energies of about 2.5 MeV with subsequent moderation and filtering for shaping epithermal neutron beams for BNCT. Moderator, filter, and shielding assemblies have been modeled using MCNP. Head-phantom dose distributions have been calculated using the treatment planning software BNCT{_}RTPE. The simulation studies have shown that a proton beam current of {approximately} 20 mA is required to deliver high quality brain treatments in about 40 minutes. The results also indicate that significantly higher doses can be delivered to deep-seated tumors in comparison to the Brookhaven Medical Research Reactor beam. An electrostatic quadrupole (ESQ) accelerator is ideally suited to provide the high beam currents desired. A novel power supply utilizing the air-coupled transformer concept is under development. It will enable the ESQ-accelerator to deliver proton beam currents exceeding 50 mA. A lithium target has been designed which consists of a thin layer of lithium on an aluminum backing. Closely spaced, narrow coolant passages cut into the aluminum allow the removal of a 50kW heat-load by convective water cooling. The system under development is suitable for hospital installation and has the potential for providing neutron beams superior to reactor sources.

  16. Proposed second harmonic acceleration system for the intense pulsed neutron source rapid cycling synchrotron

    SciTech Connect

    Norem, J.; Brandeberry, F.; Rauchas, A.

    1983-01-01

    The Rapid Cycling Synchrotron (RCS) of the Intense Pulsed Neutron Source (IPNS) operating at Argonne National Laboratory is presently producing intensities of 2 to 2.5 x 10/sup 12/ protons per pulse (ppp) with the addition of a new ion source. This intensity is close to the space charge limit of the machine, estimated at approx.3 x 10/sup 12/ ppp, depending somewhat on the available aperture. With the present good performance in mind, accelerator improvements are being directed at: (1) increasing beam intensities for neutron science; (2) lowering acceleration losses to minimize activation; and (3) gaining better control of the beam so that losses can be made to occur when and where they can be most easily controlled. On the basis of preliminary measurements, we are now proposing a third cavity for the RF systems which would provide control of the longitudinal bunch shape during the cycle which would permit raising the effective space charge limit of the accelerator and reducing losses.

  17. A comparison between a TESQ accelerator and a reactor as a neutron sources for BNCT

    NASA Astrophysics Data System (ADS)

    Burlon, A. A.; Kreiner, A. J.

    2008-03-01

    In this work, the performance of an accelerator-based neutron source design has been compared with that of a modern fluoride-filtered reactor-based epithermal beam having near-optimal quality for treatment of deep seated tumors in relation to its applicability for BNCT. The accelerator is a Tandem-Electrostatic-Quadrupole (TESQ) accelerator which is a design under development at the National Atomic Energy Commission (CNEA) in Buenos Aires, Argentina based on the 7Li(p,n)7Be reaction, relatively close to its energy threshold. The reactor is the Massachusetts Institute of Technology reactor upgraded with a Fission Converter Beam (MIT-FCB) and improved with an 8 mm thick 6Li filter. The comparison has been done by means of data reported on the MIT-FCB + 6Li filter performance and MCNP simulations on our TESQ design considering the neutron fluxes provided by the two sources and the doses delivered in a human phantom by both devices. The results show a deeper advantage depth (AD) for the TESQ which turns out to be a promising alternative to a reactor-based BNCT treatment.

  18. Development of beryllium-based neutron target system with three-layer structure for accelerator-based neutron source for boron neutron capture therapy.

    PubMed

    Kumada, Hiroaki; Kurihara, Toshikazu; Yoshioka, Masakazu; Kobayashi, Hitoshi; Matsumoto, Hiroshi; Sugano, Tomei; Sakurai, Hideyuki; Sakae, Takeji; Matsumura, Akira

    2015-12-01

    The iBNCT project team with University of Tsukuba is developing an accelerator-based neutron source. Regarding neutron target material, our project has applied beryllium. To deal with large heat load and blistering of the target system, we developed a three-layer structure for the target system that includes a blistering mitigation material between the beryllium used as the neutron generator and the copper heat sink. The three materials were bonded through diffusion bonding using a hot isostatic pressing method. Based on several verifications, our project chose palladium as the intermediate layer. A prototype of the neutron target system was produced. We will verify that sufficient neutrons for BNCT treatment are generated by the device in the near future. PMID:26260448

  19. Accelerating Data Acquisition, Reduction, and Analysis at the Spallation Neutron Source

    SciTech Connect

    Campbell, Stuart I; Kohl, James Arthur; Granroth, Garrett E; Miller, Ross G; Doucet, Mathieu; Stansberry, Dale V; Proffen, Thomas E; Taylor, Russell J; Dillow, David

    2014-01-01

    ORNL operates the world's brightest neutron source, the Spallation Neutron Source (SNS). Funded by the US DOE Office of Basic Energy Science, this national user facility hosts hundreds of scientists from around the world, providing a platform to enable break-through research in materials science, sustainable energy, and basic science. While the SNS provides scientists with advanced experimental instruments, the deluge of data generated from these instruments represents both a big data challenge and a big data opportunity. For example, instruments at the SNS can now generate multiple millions of neutron events per second providing unprecedented experiment fidelity but leaving the user with a dataset that cannot be processed and analyzed in a timely fashion using legacy techniques. To address this big data challenge, ORNL has developed a near real-time streaming data reduction and analysis infrastructure. The Accelerating Data Acquisition, Reduction, and Analysis (ADARA) system provides a live streaming data infrastructure based on a high-performance publish subscribe system, in situ data reduction, visualization, and analysis tools, and integration with a high-performance computing and data storage infrastructure. ADARA allows users of the SNS instruments to analyze their experiment as it is run and make changes to the experiment in real-time and visualize the results of these changes. In this paper we describe ADARA, provide a high-level architectural overview of the system, and present a set of use-cases and real-world demonstrations of the technology.

  20. (International Panel on 14 MeV Intense Neutron Source Based on Accelerators for Fusion Materials Study)

    SciTech Connect

    Thoms, K.R.; Wiffen, F.W.

    1991-02-14

    Both travelers were members of a nine-person US delegation that participated in an international workshop on accelerator-based 14 MeV neutron sources for fusion materials research hosted by the University of Tokyo. Presentations made at the workshop reviewed the technology developed by the FMIT Project, advances in accelerator technology, and proposed concepts for neutron sources. One traveler then participated in the initial meeting of the IEA Working Group on High Energy, High Flux Neutron Sources in which efforts were begun to evaluate and compare proposed neutron sources; the Fourth FFTF/MOTA Experimenters' Workshop which covered planning and coordination of the US-Japan collaboration using the FFTF reactor to irradiate fusion reactor materials; and held discussions with several JAERI personnel on the US-Japan collaboration on fusion reactor materials.

  1. NEUTRON SOURCE

    DOEpatents

    Bernander, N.K. et al.

    1960-10-18

    An apparatus is described for producing neutrons through target bombardment with deuterons. Deuterium gas is ionized by electron bombardment and the deuteron ions are accelerated through a magnetic field to collimate them into a continuous high intensity beam. The ion beam is directed against a deuteron pervious metal target of substantially the same nnaterial throughout to embed the deuterous therein and react them to produce neutrons. A large quantity of neutrons is produced in this manner due to the increased energy and quantity of ions bombarding the target.

  2. Neutron source

    DOEpatents

    Cason, J.L. Jr.; Shaw, C.B.

    1975-10-21

    A neutron source which is particularly useful for neutron radiography consists of a vessel containing a moderating media of relatively low moderating ratio, a flux trap including a moderating media of relatively high moderating ratio at the center of the vessel, a shell of depleted uranium dioxide surrounding the moderating media of relatively high moderating ratio, a plurality of guide tubes each containing a movable source of neutrons surrounding the flux trap, a neutron shield surrounding one part of each guide tube, and at least one collimator extending from the flux trap to the exterior of the neutron source. The shell of depleted uranium dioxide has a window provided with depleted uranium dioxide shutters for each collimator. Reflectors are provided above and below the flux trap and on the guide tubes away from the flux trap.

  3. ACCELERATOR SYSTEMS MODIFICATIONS FOR A SECOND TARGET STATION AT THE OAK RIDGE SPALLATION NEUTRON SOURCE

    SciTech Connect

    Galambos, John D; Kim, Sang-Ho; Plum, Michael A

    2014-01-01

    A second target station is planned for the Oak Ridge Spallation Neutron Source. The ion source will be upgraded to increase the peak current from 38 to 49 mA, additional superconducting RF cavities will be added to the linac to increase the H beam energy from 938 to 1300 MeV, and the accumulator ring will receive modifications to the injection and extraction systems to accommodate the higher beam energy. After pulse compression in the storage ring one sixth of the beam pulses (10 out of 60 Hz) will be diverted to the second target by kicker and septum magnets added to the existing Ring to Target Beam Transport (RTBT) line. No further modifications will be made to the RTBT so that when the kicker and septum magnets are turned off the original beam transport lattice will be unaffected. In this paper we will discuss these and other planned modifications and upgrades to the accelerator facility.

  4. NEUTRON SOURCES

    DOEpatents

    Richmond, J.L.; Wells, C.E.

    1963-01-15

    A neutron source is obtained without employing any separate beryllia receptacle, as was formerly required. The new method is safer and faster, and affords a source with both improved yield and symmetry of neutron emission. A Be container is used to hold and react with Pu. This container has a thin isolating layer that does not obstruct the desired Pu--Be reaction and obviates procedures previously employed to disassemble and remove a beryllia receptacle. (AEC)

  5. Feasibility study of an intense pulsed neutron source based on a powerful electron accelerator and a pulsed nuclear reactor

    SciTech Connect

    Bosamykin, V.S.; Voinov, M.A.; Gordeev, V.S.; Kuvshinov, M.I.; Morunov, K.A.; Pavlovskii, A.I.; Selemir, V.D.

    1995-12-31

    A promising candidate for a highly intense neutron source is a system coupling a powerful pulsed electron accelerator and a pulsed fast-neutron nuclear reactor. The LIU-10-GIR complex, located at the All-Russian Institute of Experimental Physics (VNIIEF), is described. Experiments were carried out during 1984--1990 to study the joint operation of these two widely differing physical systems and resolve basic scientific research problems. Experimental results are given, and the potential use of such a system as an intense neutron source is suggested.

  6. NEUTRON SOURCE

    DOEpatents

    Foster, J.S. Jr.

    1960-04-19

    A compact electronic device capable of providing short time high density outputs of neutrons is described. The device of the invention includes an evacuated vacuum housing adapted to be supplied with a deuterium, tritium, or other atmosphere and means for establishing an electrical discharge along a path through the gas. An energized solenoid is arranged to constrain the ionized gas (plasma) along the path. An anode bearing adsorbed or adherent target material is arranged to enclose the constrained plasma. To produce neutrons a high voltage is applied from appropriate supply means between the plasma and anode to accelerate ions from the plasma to impinge upcn the target material, e.g., comprising deuterium.

  7. Laser-driven x-ray and neutron source development for industrial applications of plasma accelerators

    NASA Astrophysics Data System (ADS)

    Brenner, C. M.; Mirfayzi, S. R.; Rusby, D. R.; Armstrong, C.; Alejo, A.; Wilson, L. A.; Clarke, R.; Ahmed, H.; Butler, N. M. H.; Haddock, D.; Higginson, A.; McClymont, A.; Murphy, C.; Notley, M.; Oliver, P.; Allott, R.; Hernandez-Gomez, C.; Kar, S.; McKenna, P.; Neely, D.

    2016-01-01

    Pulsed beams of energetic x-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and x-ray beam generation. Measurements and Monte Carlo radiation transport simulations show that neutron yield is increased by a factor ~2 when a 1 mm copper foil is placed behind a 2 mm lithium foil, compared to using a 2 cm block of lithium only. We explore x-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using  >1 ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte Carlo code. We also demonstrate the unique capability of laser-driven x-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10 ps drive pulse is presented for the first time, demonstrating that features of 200 μm size are resolved when projected at high magnification.

  8. NIFTI and DISCOS: New concepts for a compact accelerator neutron source for boron neutron capture therapy applications

    SciTech Connect

    Powell, J.; Ludewig, H.; Todosow, M.; Reich, M.

    1995-06-01

    Two new concepts, NIFTI and DISCOS, are described. These concepts enable the efficient production of epithermal neutrons for BNCT (Boron Neutron Capture Therapy) medical treatment, utilizing a low current, low energy proton beam impacting on a lithium target. The NIFTI concept uses fluoride compounds, such as lead or beryllium fluoride, to efficiently degrade high energy neutrons from the lithium target to the lower energies required for BNCT. The fluoride compounds are in turn encased in an iron layer that strongly impedes the transmission of neutrons with energies above 24 KeV. Lower energy neutrons readily pass through this iron filter, which has a deep window in its scattering cross section at 24 KeV. The DISCOS concept uses a rapidly rotating, high g disc to create a series of thin ({approximately} 1 micron thickness) liquid lithium targets in the form of continuous films or sheets of discrete droplets--through which the proton beam passes. The average energy lost by a proton as it passes through a single target is small, approximately 10 KeV. Between the targets, the proton beam is re-accelerated by an applied DC electric field. The DISCOS approach enables the accelerator--target facility to operate with a beam energy only slightly above the threshold value for neutron production--resulting in an output beam of low-energy epithermal neutrons--while achieving a high yield of neutrons per milliamp of proton beam current. Parametric trade studies of the NIFTI and DISCOS concepts are described. These include analyses of a broad range of NIFTI designs using the Monte carlo MCNP neutronics code, as well as mechanical and thermal-hydraulic analyses of various DISCOS designs.

  9. Conceptual design of thorium-fuelled Mitrailleuse accelerator-driven subcritical reactor using D-Be neutron source

    SciTech Connect

    Kokubo, Y.; Kamei, T.

    2012-07-01

    A distributed accelerator is a charged-particle accelerator that uses a new acceleration method based on repeated electrostatic acceleration. This method offers outstanding benefits not possible with the conventional radio-frequency acceleration method, including: (1) high acceleration efficiency, (2) large acceleration current, and (3) lower failure rate made possible by a fully solid-state acceleration field generation circuit. A 'Mitrailleuse Accelerator' is a product we have conceived to optimize this distributed accelerator technology for use with a high-strength neutron source. We have completed the conceptual design of a Mitrailleuse Accelerator and of a thorium-fuelled subcritical reactor driven by a Mitrailleuse Accelerator. This paper presents the conceptual design details and approach to implementing the subcritical reactor core. We will spend the next year or so on detailed design work, and then will start work on developing a prototype for demonstration. If there are no obstacles in setting up a development organization, we expect to finish verifying the prototype's performance by the third quarter of 2015. (authors)

  10. Lorentz force detuning analysis of the Spallation Neutron Source (SNS) accelerating cavities.

    SciTech Connect

    Mitchell, R.R.; Matsumoto, K. Y.; Ciovati, G.; Davis, K.; Macha, K.; Sundelin, R. M.

    2001-01-01

    The Spallation Neutron Source (SNS) project incorporates a superconducting radio-frequency (SRF) accelerator for the final section of the pulsed mode linac. Cavities with geometrical {beta} values of {beta}=0.61 and {beta}=0.81 are utilized in the SRF section, and are constructed out of thin-walled niobium with stiffener rings welded between the cells near the iris. The welded titanium helium vessel and tuner assembly restrains the cavity beam tubes. Cavities with {beta} values less than one have relatively steep and flat side-walls making the cavities susceptible to Lorentz force detuning. In addition, the pulsed RF induces cyclic Lorentz pressures that mechanically excite the cavities, producing a dynamic Lorentz force detuning different from a continuous RF system. The amplitude of the dynamic detuning for a given cavity design is a function of the mechanical damping, stiffness of the tuner/helium vessel assembly, RF pulse profile, and the RF pulse rate. This paper presents analysis and testing results to date, and indicates areas where more investigation is required.

  11. NEUTRON SOURCE

    DOEpatents

    Reardon, W.A.; Lennox, D.H.; Nobles, R.G.

    1959-01-13

    A neutron source of the antimony--beryllium type is presented. The source is comprised of a solid mass of beryllium having a cylindrical recess extending therein and a cylinder containing antimony-124 slidably disposed within the cylindrical recess. The antimony cylinder is encased in aluminum. A berylliunn plug is removably inserted in the open end of the cylindrical recess to completely enclose the antimony cylinder in bsryllium. The plug and antimony cylinder are each provided with a stud on their upper ends to facilitate handling remotely.

  12. Mechanical Design and Analysis of a 200 MHz, Bolt-together RFQ forthe Accelerator Driven Neutron Source

    SciTech Connect

    Virostek, Steve; Hoff, Matt; Li, Derun; Staples, John; Wells,Russell

    2007-06-20

    A high-yield neutron source to screen sea-land cargocontainers for shielded Special Nuclear Materials (SNM) has been designedat LBNL [1,2]. The Accelerator-Driven Neutron Source (ADNS) uses theD(d,n)3He reaction to create a forward directed neutron beam. Keycomponents are a high-current radio-frequency quadrupole (RFQ)accelerator and a high-power target capable of producing a neutron fluxof>107 n/(cm2 cdot s) at a distance of 2.5 m. The mechanical designand analysis of the four-module, bolt-together RFQ will be presentedhere. Operating at 200 MHz, the 5.1 m long RFQ will accelerate a 40 mAdeuteron beam to 6 MeV. At a 5 percent duty factor, the time-average d+beam current on target is 1.5 mA. Each of the 1.27 m long RFQ moduleswill consist of four solid OFHC copper vanes. A specially designed 3-DO-ring will provide vacuum sealing between both the vanes and themodules. RF connections are made with canted coil spring contacts. Aseries of 60 water-cooled pi-mode rods provides quadrupole modestabilization. A set of 80 evenly spaced fixed slug tuners is used forfinal frequency adjustment and local field perturbationcorrection.

  13. Neutron source, linear-accelerator fuel enricher and regenerator and associated methods

    DOEpatents

    Steinberg, Meyer; Powell, James R.; Takahashi, Hiroshi; Grand, Pierre; Kouts, Herbert

    1982-01-01

    A device for producing fissile material inside of fabricated nuclear elements so that they can be used to produce power in nuclear power reactors. Fuel elements, for example, of a LWR are placed in pressure tubes in a vessel surrounding a liquid lead-bismuth flowing columnar target. A linear-accelerator proton beam enters the side of the vessel and impinges on the dispersed liquid lead-bismuth columns and produces neutrons which radiate through the surrounding pressure tube assembly or blanket containing the nuclear fuel elements. These neutrons are absorbed by the natural fertile uranium-238 elements and are transformed to fissile plutonium-239. The fertile fuel is thus enriched in fissile material to a concentration whereby they can be used in power reactors. After use in the power reactors, dispensed depleted fuel elements can be reinserted into the pressure tubes surrounding the target and the nuclear fuel regenerated for further burning in the power reactor.

  14. Accelerators and Neutron Capture Therapy

    NASA Astrophysics Data System (ADS)

    Burlon, A. A.; Kreiner, A. J.; Valda, A.

    2002-08-01

    Within the frame of Accelerator Based Boron Neutron Capture Therapy (AB-BNCT), the 7Li (p,n) 7Be reaction, relatively near its energy threshold is one of the most promising, due to its high yield and low neutron energy. In this work a thick LiF target irradiated with a proton beam was studied as a neutron source. The 1.88-2.0 MeV proton beam was produced by the tandem accelerator TANDAR at CNEA's facilities in Buenos Aires. A water-filled phantom, containing a boron sample was irradiated with the resulting neutron flux. The 10B(n,αγ)7Li boron neutron capture reaction produces a 0.478 MeV gamma ray in 94% of the cases. The neutron yield was measured through the detection of this gamma ray using a hyperpure germanium detector with an anti-Compton shield. In addition, the thermal neutron flux was evaluated at different depths inside the phantom using bare and Cd-covered gold foils. A maximum neutron thermal flux of 1.4×108 cm-2s-1mA-1 was obtained at 4.2 cm from the phantom surface. In order to optimize the design of the neutron production target and the beam shaping assembly extensive Monte Carlo Neutron and Photon (MCNP) simulations have been performed. Neutron fields from a thick LiF and a Li metal target (with both a D2O-graphite and a Al/AlF3-graphite moderator/reflector assembly) were evaluated along the centerline of a head and a whole body phantom. Simulations were carried out for 1.89, 2.0 and 2.3 MeV proton beams. The results show that it is more advantageous to irradiate the target with 2.3 MeV near-resonance protons, instead of very near threshold, because of the higher neutron yield at this energy. On the other hand, the Al/AlF3-graphite exhibits a more efficient performance than D2O in terms of tumor to maximum healthy tissue dose ratio. Treatment times of less than 15 min and tumor control probabilities larger than 98% are obtained for a 50 mA, 2.3 MeV proton beam. The alternative neutron-producing reaction 13C(d,n) is also briefly reviewed. A

  15. Demonstration of a high-intensity neutron source based on a liquid-lithium target for Accelerator based Boron Neutron Capture Therapy.

    PubMed

    Halfon, S; Arenshtam, A; Kijel, D; Paul, M; Weissman, L; Berkovits, D; Eliyahu, I; Feinberg, G; Kreisel, A; Mardor, I; Shimel, G; Shor, A; Silverman, I; Tessler, M

    2015-12-01

    A free surface liquid-lithium jet target is operating routinely at Soreq Applied Research Accelerator Facility (SARAF), bombarded with a ~1.91 MeV, ~1.2 mA continuous-wave narrow proton beam. The experiments demonstrate the liquid lithium target (LiLiT) capability to constitute an intense source of epithermal neutrons, for Accelerator based Boron Neutron Capture Therapy (BNCT). The target dissipates extremely high ion beam power densities (>3 kW/cm(2), >0.5 MW/cm(3)) for long periods of time, while maintaining stable conditions and localized residual activity. LiLiT generates ~3×10(10) n/s, which is more than one order of magnitude larger than conventional (7)Li(p,n)-based near threshold neutron sources. A shield and moderator assembly for BNCT, with LiLiT irradiated with protons at 1.91 MeV, was designed based on Monte Carlo (MCNP) simulations of BNCT-doses produced in a phantom. According to these simulations it was found that a ~15 mA near threshold proton current will apply the therapeutic doses in ~1h treatment duration. According to our present results, such high current beams can be dissipated in a liquid-lithium target, hence the target design is readily applicable for accelerator-based BNCT. PMID:26300076

  16. Conceptual Design of Dielectric Accelerating Structures for Intense Neutron and Monochromatic X-ray Sources

    SciTech Connect

    Blanovsky, Anatoly

    2004-12-07

    Bright compact photon sources, which utilize electron beam interaction with periodic structures, may benefit a broad range of medical, industrial and scientific applications. A class of dielectric-loaded periodic structures for hard and soft X-ray production has been proposed that would provide a high accelerating gradient when excited by an external RF and/or primary electron beam. Target-distributed accelerators (TDA), in which an additional electric field compensates for lost beam energy in internal targets, have been shown to provide the necessary means to drive a high flux subcritical reactor (HFSR) for nuclear waste transmutation. The TDA may also be suitable for positron and nuclear isomer production, X-ray lithography and monochromatic computer tomography. One of the early assumptions of the theory of dielectric wake-field acceleration was that, in electrodynamics, the vector potential was proportional to the scalar potential. The analysis takes into consideration a wide range of TDA design aspects including the wave model of observed phenomena, a layered compound separated by a Van der Waals gap and a compact energy source based on fission electric cells (FEC) with a multistage collector. The FEC is a high-voltage power source that directly converts the kinetic energy of the fission fragments into electrical potential of about 2MV.

  17. Direct current H{sup -} source for boron neutron capture therapy tandem accelerator

    SciTech Connect

    Belchenko, Yu.; Sanin, A.; Gusev, I.; Khilchenko, A.; Kvashnin, A.; Rashchenko, V.; Savkin, V.; Zubarev, P.

    2008-02-15

    One year experience of dc H{sup -} source operation at 2 MeV tandem accelerator is described. The source delivers H{sup -} ion beams with controlled current in the range of 1-8 mA and energy up to 25 keV. Normalized 1 rms emittance for 8 mA beam is less than 0.2{pi} mm mrad. Negative ions are produced on the cesiated anode of the Penning discharge, driven by plasma injection from the hollow cathode inserts.

  18. Final Report US-Japan IEC Workshop on Small Plasma and Accelerator Neutron Sources

    SciTech Connect

    Miley, George, H.

    2008-06-04

    Abstract The history of IEC development will be briefly described, and some speculation about future directions will be offered. The origin of IEC is due to the brilliance of Phil Farnsworth, inventor of electronic TV in the US. Early experiments were pioneered in the late 1960s by Robert Hirsch who later became head of the DOE fusion program. At that time studies of IEC physics quickly followed at the University of Illinois and at Penn State University. However, despite many successes in this early work, IEC research died as DOE funding stopped in the mid 1980s. In the early 90’s, R. W. Bussard of EMC revived work with a new major project based on a magnetic assisted IEC. While doing supportive studies for that project, G. Miley proposed a grided “STAR mode” IEC as a neutron source for NAA. This concept was later used commercially by Daimler- Benz in Germany to analysis impurities in incoming ores. This represented a first practical application of the IEC. During this period other research groups at LANL, U of Wisconsin and Kyoto University entered IEC research with innovative new concepts and approaches to IEC physics and applications. Much of this work is documented in the present and in past US-Japan Workshops. At present we stand on the threshold of a new area of IEC applications as neutron source, for isotope production, and as a plasma source. These applications provide a way to continue IEC understanding and technology development with the ultimate goal being a fusion power plant. Indeed, a distinguishing feature of the IEC vs. other fusion confinement approaches is the unique opportunity for “spin off” applications along the way to a power producing plant.

  19. Optimal moderator materials at various proton energies considering photon dose rate after irradiation for an accelerator-driven ⁹Be(p, n) boron neutron capture therapy neutron source.

    PubMed

    Hashimoto, Y; Hiraga, F; Kiyanagi, Y

    2015-12-01

    We evaluated the accelerator beam power and the neutron-induced radioactivity of (9)Be(p, n) boron neutron capture therapy (BNCT) neutron sources having a MgF2, CaF2, or AlF3 moderator and driven by protons with energy from 8 MeV to 30 MeV. The optimal moderator materials were found to be MgF2 for proton energies less than 10 MeV because of lower required accelerator beam power and CaF2 for higher proton energies because of lower photon dose rate at the treatment position after neutron irradiation. PMID:26272165

  20. Accelerator-based neutron source using a cold deuterium target with degenerate electrons

    SciTech Connect

    Phillips, R. E.; Ordonez, C. A.

    2013-07-15

    A neutron generator is considered in which a beam of tritons is incident on a hypothetical cold deuterium target with degenerate electrons. The energy efficiency of neutron generation is found to increase substantially with electron density. Recent reports of potential targets are discussed.

  1. Mobile accelerator neutron radiography system

    NASA Astrophysics Data System (ADS)

    Dance, W. E.; Carollo, S. F.; Bumgardner, H. M.

    1984-10-01

    The use of neutron radiography for the inspection and maintenance of large structures such as aircraft has been delayed by the absence of a mobile system particularly suited to the requirements of field use. This report describes the production, extensive field testing, evaluation and disposition of the first mobile neutron radiography system to satisfy the majority of requirements for field use. The system is based upon the concept of a mobile on-off neutron radiography system based on a sealed-tube ion accelerator as neutron source demonstrated earlier by the Vought Corporation. Primary features of the system are its self-propelled mobility, versatile positioning capability scaled to Army helicopter dimensions, an on-off beam capability, exposure capability measured in minutes, and suitability for AMMRC laboratory and field use. Included in the report are a description of all components of the system, an evaluation of the operation of the system, an evaluation of its radiographic capabilities, a description of installation elements for the AMMRC site, and recommendations for next-generation systems.

  2. PRODUCTION AND APPLICATIONS OF NEUTRONS USING PARTICLE ACCELERATORS

    SciTech Connect

    David L. Chichester

    2009-11-01

    Advances in neutron science have gone hand in hand with the development and of particle accelerators from the beginning of both fields of study. Early accelerator systems were developed simply to produce neutrons, allowing scientists to study their properties and how neutrons interact in matter, but people quickly realized that more tangible uses existed too. Today the diversity of applications for industrial accelerator-based neutron sources is high and so to is the actual number of instruments in daily use is high, and they serve important roles in the fields where they're used. This chapter presents a technical introduction to the different ways particle accelerators are used to produce neutrons, an historical overview of the early development of neutron-producing particle accelerators, a description of some current industrial accelerator systems, narratives of the fields where neutron-producing particle accelerators are used today, and comments on future trends in the industrial uses of neutron producing particle accelerators.

  3. Vacuum seals design and testing for a linear accelerator of the National Spallation Neutron Source

    SciTech Connect

    Z. Chen; C. Gautier; F. Hemez; N. K. Bultman

    2000-02-01

    Vacuum seals are very important to ensure that the Spallation Neutron Source (SNS) Linac has an optimum vacuum system. The vacuum joints between flanges must have reliable seals to minimize the leak rate and meet vacuum and electrical requirements. In addition, it is desirable to simplify the installation and thereby also simplify the maintenance required. This report summarizes an investigation of the metal vacuum seals that include the metal C-seal, Energized Spring seal, Helcoflex Copper Delta seal, Aluminum Delta seal, delta seal with limiting ring, and the prototype of the copper diamond seals. The report also contains the material certifications, design, finite element analysis, and testing for all of these seals. It is a valuable reference for any vacuum system design. To evaluate the suitability of several types of metal seals for use in the SNS Linac and to determine the torque applied on the bolts, a series of vacuum leak rate tests on the metal seals have been completed at Los Alamos Laboratory. A copper plated flange, using the same type of delta seal that was used for testing with the stainless steel flange, has also been studied and tested. A vacuum seal is desired that requires significantly less loading than a standard ConFlat flange with a copper gasket for the coupling cavity assembly. To save the intersegment space the authors use thinner flanges in the design. The leak rate of the thin ConFlat flange with a copper gasket is a baseline for the vacuum test on all seals and thin flanges. A finite element analysis of a long coupling cavity flange with a copper delta seal has been performed in order to confirm the design of the long coupling cavity flange and the welded area of a cavity body with the flange. This analysis is also necessary to predict a potential deformation of the cavity under the combined force of atmospheric pressure and the seating load of the seal. Modeling of this assembly has been achieved using both HKS/Abaqus and COSMOS

  4. Use of a small accelerator as a source of 14-MeV neutrons for shielding studies

    SciTech Connect

    Chapman, G.T.; Morgan, G.L.; McConnell, J.W.

    1980-11-01

    It is important in calculating complex shields such as those proposed for the fusion reactors to ascertain that the neutron cross-section data sets used in the calculations are as accurate as possible and that the calculational methods used to transport the neutrons are as reliable as practical. To assure that both these criteria are met, a project at the Oak Ridge National Laboratory (ORNL) is being conducted in which a small accelerator is used to provide 14-MeV neutrons via the T(d,n)/sup 4/He reaction and an NE-213 detector is used to measure the neutron and gamma-ray pulse-height spectra of the radiations transported through and/or created in very thick laminated shields of stainless steel (type 304) and borated polyethylene.

  5. High power testing of the 402.5 MHZ and 805 MHZ RF windows for the spallation neutron source accelerator

    SciTech Connect

    Cummings, K. A.; De Baca, J. M.; Harrison, J. S.; Rodriguez, M. B.; Torrez, P. A.; Warner, D. K.

    2003-01-01

    Hisorically, Radio Frequency (RF) windows have been a common point of failure in input power couplers; therefore, reliable RF windows are critical to the success of the Spallation Neutron Source (SNS) project. The normal conducting part of the SNS accelerator requires six RF windows at 402.5 MHz and eight RF windows at 805 MHz[l]. Each RF window will transmit up to 180 kW of average power and 2.5 MW peak power at 60 Hz with 1.2 millisecond pulses. The RF windows, designed and manufactured by Thales, were tested at the full average power for 4 hours to ensure no problems with the high average power and then tested to an effective forward power level of 10 MW by testing at 2.5 MW forward power into a short and varying the phase of the standing wave. The sliding short was moved from 0 to 180 degrees to ensure no arcing or breakdown problems occur in any part of the window. This paper discusses the results of the high power testing of both the 402.5 MHz and the 805 MHz RF windows. Problems encountered during testing and the solutions for these problems are discussed.

  6. Intense fusion neutron sources

    NASA Astrophysics Data System (ADS)

    Kuteev, B. V.; Goncharov, P. R.; Sergeev, V. Yu.; Khripunov, V. I.

    2010-04-01

    The review describes physical principles underlying efficient production of free neutrons, up-to-date possibilities and prospects of creating fission and fusion neutron sources with intensities of 1015-1021 neutrons/s, and schemes of production and application of neutrons in fusion-fission hybrid systems. The physical processes and parameters of high-temperature plasmas are considered at which optimal conditions for producing the largest number of fusion neutrons in systems with magnetic and inertial plasma confinement are achieved. The proposed plasma methods for neutron production are compared with other methods based on fusion reactions in nonplasma media, fission reactions, spallation, and muon catalysis. At present, intense neutron fluxes are mainly used in nanotechnology, biotechnology, material science, and military and fundamental research. In the near future (10-20 years), it will be possible to apply high-power neutron sources in fusion-fission hybrid systems for producing hydrogen, electric power, and technological heat, as well as for manufacturing synthetic nuclear fuel and closing the nuclear fuel cycle. Neutron sources with intensities approaching 1020 neutrons/s may radically change the structure of power industry and considerably influence the fundamental and applied science and innovation technologies. Along with utilizing the energy produced in fusion reactions, the achievement of such high neutron intensities may stimulate wide application of subcritical fast nuclear reactors controlled by neutron sources. Superpower neutron sources will allow one to solve many problems of neutron diagnostics, monitor nano-and biological objects, and carry out radiation testing and modification of volumetric properties of materials at the industrial level. Such sources will considerably (up to 100 times) improve the accuracy of neutron physics experiments and will provide a better understanding of the structure of matter, including that of the neutron itself.

  7. Neutron sources and applications

    SciTech Connect

    Price, D.L.; Rush, J.J.

    1994-01-01

    Review of Neutron Sources and Applications was held at Oak Brook, Illinois, during September 8--10, 1992. This review involved some 70 national and international experts in different areas of neutron research, sources, and applications. Separate working groups were asked to (1) review the current status of advanced research reactors and spallation sources; and (2) provide an update on scientific, technological, and medical applications, including neutron scattering research in a number of disciplines, isotope production, materials irradiation, and other important uses of neutron sources such as materials analysis and fundamental neutron physics. This report summarizes the findings and conclusions of the different working groups involved in the review, and contains some of the best current expertise on neutron sources and applications.

  8. Beam dynamics study of a 30 MeV electron linear accelerator to drive a neutron source

    SciTech Connect

    Kumar, Sandeep; Yang, Haeryong; Kang, Heung-Sik

    2014-02-14

    An experimental neutron facility based on 32 MeV/18.47 kW electron linac has been studied by means of PARMELA simulation code. Beam dynamics study for a traveling wave constant gradient electron accelerator is carried out to reach the preferential operation parameters (E = 30 MeV, P = 18 kW, dE/E < 12.47% for 99% particles). The whole linac comprises mainly E-gun, pre-buncher, buncher, and 2 accelerating columns. A disk-loaded, on-axis-coupled, 2π/3-mode type accelerating rf cavity is considered for this linac. After numerous optimizations of linac parameters, 32 MeV beam energy is obtained at the end of the linac. As high electron energy is required to produce acceptable neutron flux. The final neutron flux is estimated to be 5 × 10{sup 11} n/cm{sup 2}/s/mA. Future development will be the real design of a 30 MeV electron linac based on S band traveling wave.

  9. Accelerator-based neutron radioscopic systems

    NASA Astrophysics Data System (ADS)

    Berger, Harold; Dance, William E.

    1999-06-01

    There is interest in non-reactor source, thermal neutron inspection systems for applications in aircraft maintenance, explosive devices, investment-cast turbine blades, etc. Accelerator sources, (d-T), RFQ accelerators and cyclotrons as examples, are available for either transportable or fixed neutron inspection systems. Sources are reviewed for neutron output, portability, ease of use and cost, and for use with an electronic neutron imaging camera (image intensifier or scintillator-camera system) to provide a prompt response, neutron inspection system. Particular emphasis is given to the current aircraft inspection problem to detect and characterize corrosion. Systems are analyzed to determine usefulness in providing an on-line inspection technique to detect corrosion in aluminum honeycomb aircraft components, either on-aircraft or in a shop environment. The neutron imaging sensitivity to hydrogenous aluminum corrosion product offers early detection advantages for aircraft corrosion, to levels of aluminum metal loss as small as 25 μm. The practical capability for a continuous scan thermal neutron radioscopic system to inspect up to 500 square feet of component surface per day is used as an evaluation criterion, with the system showing contrast sensitivity of at least 5% and image detail in the order of 4 mm for parts 10 cm thick. Under these practical conditions and 3-shift operation, the source must provide an incident thermal neutron flux of 5.6×104n cm-2 s-1 at an L/D of 30. A stop and go inspection approach, offering improved resolution, would require a source with similar characteristics.

  10. Generation of nanosecond neutron pulses in vacuum accelerating tubes

    NASA Astrophysics Data System (ADS)

    Didenko, A. N.; Shikanov, A. E.; Rashchikov, V. I.; Ryzhkov, V. I.; Shatokhin, V. L.

    2014-06-01

    The generation of neutron pulses with a duration of 1-100 ns using small vacuum accelerating tubes is considered. Two physical models of acceleration of short deuteron bunches in pulse neutron generators are described. The dependences of an instantaneous neutron flux in accelerating tubes on the parameters of pulse neutron generators are obtained using computer simulation. The results of experimental investigation of short-pulse neutron generators based on the accelerating tube with a vacuum-arc deuteron source, connected in the circuit with a discharge peaker, and an accelerating tube with a laser deuteron source, connected according to the Arkad'ev-Marx circuit, are given. In the experiments, the neutron yield per pulse reached 107 for a pulse duration of 10-100 ns. The resultant experimental data are in satisfactory agreement with the results of computer simulation.

  11. A National Spallation Neutron Source for neutron scattering

    SciTech Connect

    Appleton, B.R.

    1996-10-01

    The National Spallation Neutron Source is a collaborative project or perform the conceptual design for a next generation neutron source for the Department of Energy. This paper reviews the need and justification for a new neutron source, the origins and structure of the collaboration formed to address this need, and the community input leading up to the current design approach. A reference design is presented for an accelerator based spallation neutron source that would begin operation at about 1 megawatt of power but designed so that it could be upgraded to significantly higher powers in the future. The technology approach, status, and progress on the conceptual design to date are presented.

  12. Pulsed spallation Neutron Sources

    SciTech Connect

    Carpenter, J.M.

    1994-12-31

    This paper reviews the early history of pulsed spallation neutron source development at Argonne and provides an overview of existing sources world wide. A number of proposals for machines more powerful than currently exist are under development, which are briefly described. The author reviews the status of the Intense Pulsed Neutron Source, its instrumentation, and its user program, and provides a few examples of applications in fundamental condensed matter physics, materials science and technology.

  13. Pulsed spallation neutron sources

    SciTech Connect

    Carpenter, J.M.

    1996-05-01

    This paper reviews the early history of pulsed spallation neutron source development ar Argonne and provides an overview of existing sources world wide. A number of proposals for machines more powerful than currently exist are under development, which are briefly described. The author reviews the status of the Intense Pulsed Neutron Source, its instrumentation, and its user program, and provide a few examples of applications in fundamental condensed matter physics, materials science and technology.

  14. The Advanced Neutron Source

    SciTech Connect

    Hayter, J.B.

    1989-01-01

    The Advanced Neutron Source (ANS) is a new user experimental facility planned to be operational at Oak Ridge in the late 1990's. The centerpiece of the ANS will be a steady-state research reactor of unprecedented thermal neutron flux ({phi}{sub th} {approx} 9{center dot}10{sup 19} m{sup -2}{center dot}s{sup -1}) accompanied by extensive and comprehensive equipment and facilities for neutron-based research. 5 refs., 5 figs.

  15. Reactions and moderators for an accelerator-based epithermal neutron capture therapy source for cancer treatment. Final report, October 1900--September 1994

    SciTech Connect

    Kunze, J.F.; Brugger, R.M.

    1995-03-01

    The use of boron neutron capture therapy (BNCT) has been considered for nearly 30 years, and been practiced in Japan since the late 1970`s. Early experiments in the USA were generally nonpromising. However, new boron-containing ligand compounds were developed, which would seek out brain tumors. Concentration levels of the order of 30 micrograms of boron per gram of tissue become possible, and interest in the BNCT technique was revived in the USA beginning about 1985, with research reactors as the obvious source of the neutrons for the treatment. However, the limited number of research reactors in the USA (and the world) would mean that this treatment modality would be quite limited. The goals of this work was: (1) Examine as many as possible reactions of charged particles on various targets of an accelerator, and determine those that would give high neutron yields of a convenient energy. (2) Determine, through calculations (using Monte Carlo stochastic computer codes), the best design for a moderator/reflector assembly which would give high thermal flux at a nominal 5 cm depth in the head of a patient, with minimal radiation dose from gamma rays and fast neutrons. (3) Perform a benchmark experiment using a positive ion accelerator. The Li-7(p,n) reaction was chosen for the benchmark, since it was readily available for most accelerators, and was one of the two highest yielding reactions from Task No. 1. Since the University of Missouri has no accelerator, possible accelerators at other universities were investigated, as to availability and cost. A unit having capability in the 2.5 MeV range was desired.

  16. Neutron sources: Present practice and future potential

    SciTech Connect

    Cierjacks, S.; Smith, A.B.

    1988-01-01

    The present capability and future potential of accelerator-based monoenergetic and white neutron sources are outlined in the context of fundamental and applied neutron-nuclear research. The neutron energy range extends from thermal to 500 MeV, and the time domain from steady-state to pico-second pulsed sources. Accelerator technology is summarized, including the production of intense light-ion, heavy-ion and electron beams. Target capabilities are discussed with attention to neutron-producing efficiency and power-handling capabilities. The status of underlying neutron-producing reactions is summarized. The present and future use of neutron sources in: fundamental neutron-nuclear research, nuclear data acquisition, materials damage studies, engineering tests, and biomedical applications are discussed. Emphasis is given to current status, near-term advances well within current technology, and to long-range projections. 90 refs., 4 figs.

  17. Neutron sources: present practice and future potential

    SciTech Connect

    Cierjacks, S.; Smith, A.B.

    1988-01-01

    The present capability and future potential of accelerator-based monoenergetic and white neutron sources are outlined in the context of fundamental and applied neutron-nuclear research. The neutron energy range extends from thermal to 500+ MeV, and the time domain from steady-state to pico-second pulsed sources. Accelerator technology is summarized, including the production of intense light-ion, heavy-ion and electron beams. Target capabilities are discussed with attention to neutron-production efficiency and power-handling capabilities. The status of underlying neutron-producing reactions is summarized. The present and future use of neutron sources in: (i) fundamental neutron-nuclear research, (ii) nuclear-data acquisition, (iii) materials-damage studies, (iv) engineering test, and (v) biomedical applications are discussed. Emphasis is given to current status, near-term advances well within current technology, and to long-range projections.

  18. THERMAL NEUTRON INTENSITIES IN SOILS IRRADIATED BY FAST NEUTRONS FROM POINT SOURCES. (R825549C054)

    EPA Science Inventory

    Thermal-neutron fluences in soil are reported for selected fast-neutron sources, selected soil types, and selected irradiation geometries. Sources include 14 MeV neutrons from accelerators, neutrons from spontaneously fissioning 252Cf, and neutrons produced from alp...

  19. Compact ion source neutron generator

    SciTech Connect

    Schenkel, Thomas; Persaud, Arun; Kapadia, Rehan; Javey, Ali; Chang-Hasnain, Constance; Rangelow, Ivo; Kwan, Joe

    2015-10-13

    A neutron generator includes a conductive substrate comprising a plurality of conductive nanostructures with free-standing tips and a source of an atomic species to introduce the atomic species in proximity to the free-standing tips. A target placed apart from the substrate is voltage biased relative to the substrate to ionize and accelerate the ionized atomic species toward the target. The target includes an element capable of a nuclear fusion reaction with the ionized atomic species to produce a one or more neutrons as a reaction by-product.

  20. Ultrashort pulsed neutron source.

    PubMed

    Pomerantz, I; McCary, E; Meadows, A R; Arefiev, A; Bernstein, A C; Chester, C; Cortez, J; Donovan, M E; Dyer, G; Gaul, E W; Hamilton, D; Kuk, D; Lestrade, A C; Wang, C; Ditmire, T; Hegelich, B M

    2014-10-31

    We report on a novel compact laser-driven neutron source with an unprecedented short pulse duration (<50  ps) and high peak flux (>10(18)  n/cm(2)/s), an order of magnitude higher than any existing source. In our experiments, high-energy electron jets are generated from thin (<3  μm) plastic targets irradiated by a petawatt laser. These intense electron beams are employed to generate neutrons from a metal converter. Our method opens venues for enhancing neutron radiography contrast and for creating astrophysical conditions of heavy element synthesis in the laboratory. PMID:25396373

  1. Ultrashort Pulsed Neutron Source

    NASA Astrophysics Data System (ADS)

    Pomerantz, I.; McCary, E.; Meadows, A. R.; Arefiev, A.; Bernstein, A. C.; Chester, C.; Cortez, J.; Donovan, M. E.; Dyer, G.; Gaul, E. W.; Hamilton, D.; Kuk, D.; Lestrade, A. C.; Wang, C.; Ditmire, T.; Hegelich, B. M.

    2014-10-01

    We report on a novel compact laser-driven neutron source with an unprecedented short pulse duration (<50 ps ) and high peak flux (>1018 n /cm2/s ), an order of magnitude higher than any existing source. In our experiments, high-energy electron jets are generated from thin (<3 μ m ) plastic targets irradiated by a petawatt laser. These intense electron beams are employed to generate neutrons from a metal converter. Our method opens venues for enhancing neutron radiography contrast and for creating astrophysical conditions of heavy element synthesis in the laboratory.

  2. FABRICATION OF NEUTRON SOURCES

    DOEpatents

    Birden, J.H.

    1959-04-21

    A method is presented for preparing a neutron source from polonium-210 and substances, such as beryllium and boron, characterized by emission of neutrons upon exposure to alpha particles from the polonium. According to the invention, a source is prepared by placing powdered beryllium and a platinum foil electroplated with polonium-2;.0 in a beryllium container. The container is sealed and then heated by induction to a temperature of 450 to 1100 deg C to volatilize the polonium off the foil into the powder. The heating step is terminated upon detection of a maximum in the neutron flux level.

  3. Basic concept for an accelerator-driven subcritical system to be used as a long-pulse neutron source for Condensed Matter research

    NASA Astrophysics Data System (ADS)

    Vivanco, R.; Ghiglino, A.; de Vicente, J. P.; Sordo, F.; Terrón, S.; Magán, M.; Perlado, J. M.; Bermejo, F. J.

    2014-12-01

    A model for an accelerator-driven subcritical system to be operated as a source of cold neutrons for Condensed Matter research is developed at the conceptual level. Its baseline layout relies upon proven accelerator, spalattion target and fuel array technologies, and consists in a proton accelerator able to deliver some 67.5 mA of proton beam with kinetic energy 0.6 GeV, a pulse length of 2.86 ms, and repetition rate of 14 Hz. The particle beam hits a target of conventional design that is surrounded by a multiplicative core made of fissile/fertile material, composed by a subcritical array of fuel bars made of aluminium Cermet cooled by light water poisoned with boric acid. Relatively low enriched uranium is chosen as fissile material. An optimisation of several parameters is carried out, using as components of the objective function several characteristics pertaining the cold neutron pulse. The results show that the optimal device will deliver up to 80% of the cold neutron flux expected for some of the ongoing projects using a significantly lower proton beam power than that managed in such projects. The total power developed within the core rises up to 22.8 MW, and the criticality range shifts to a final keff value of around 0.9 after the 50 days cycle.

  4. {sup 233}U breeding measurements in a thorium-oxide blanket assembly using A (d,t) accelerator neutron source

    SciTech Connect

    Anand, R.P.; Basu, T.K.; Ramakrishna, D.V.S.

    1997-05-01

    Uranium-233 breeding studies are carried out in a compact thorium-oxide cylindrical blanket assembly surrounded by a thick polypropylene reflector in a fusion neutron environment. The assembly consists of 11 rings of thorium-oxide rods stacked in a hexagonal geometry with a central through channel for the 14-MeV (d,t) neutron source. A total of 120 thorium-oxide probes are inserted inside the rods in different axial and radial locations in the assembly, which is then subjected to 14-MeV neutron irradiation for 25 h. Protactinium-233 gamma activity produced in the probes because of neutron captures in the thorium is measured using a high-efficiency, high-purity germanium detector. The measured {sup 233}U production rates are fitted to obtain axial and radial distributions for different rings. These distributions are used to obtain the total {sup 233}U breeding in the whole assembly. The integral measured values are found to be in good agreement with the calculated values obtained employing the MCNP Monte Carlo code using the BMCCS2 cross-section library. 8 refs., 4 figs., 5 tabs.

  5. Compact Neutron Sources for Energy and Security

    NASA Astrophysics Data System (ADS)

    Uesaka, Mitsuru; Kobayashi, Hitoshi

    We choose nuclear data and nuclear material inspection for energy application, and nondestructive testing of explosive and hidden nuclear materials for security application. Low energy (~100 keV) electrostatic accelerators of deuterium are commercially available for nondestructive testing. For nuclear data measurement, electrostatic ion accelerators and L-band (1.428GHz) and S-band (2.856GHz) electron linear accelerators (linacs) are used for the neutron source. Compact or mobile X-band (9.3, 11.424GHz) electron linac neutron sources are under development. A compact proton linac neutron source is used for nondestructive testing, especially water in solids. Several efforts for more neutron intensity using proton and deuteron accelerators are also introduced.

  6. Compact Neutron Sources for Energy and Security

    NASA Astrophysics Data System (ADS)

    Uesaka, Mitsuru; Kobayashi, Hitoshi

    We choose nuclear data and nuclear material inspection for energy application, and nondestructive testing of explosive and hidden nuclear materials for security application. Low energy (˜100keV) electrostatic accelerators of deuterium are commercially available for nondestructive testing. For nuclear data measurement, electrostatic ion accelerators and L-band (1.428GHz) and S-band (2.856GHz) electron linear accelerators (linacs) are used for the neutron source. Compact or mobile X-band (9.3, 11.424GHz) electron linac neutron sources are under development. A compact proton linac neutron source is used for nondestructive testing, especially water in solids. Several efforts for more neutron intensity using proton and deuteron accelerators are also introduced.

  7. Neutron spallation sources in Europe

    NASA Astrophysics Data System (ADS)

    Bryant, P. J.

    1996-11-01

    After a brief general and historical discussion, the main design features of spallation sources are described. At the present time, Europe not only has the world-leading pulsed neutron spallation source, the SNS-ISIS at RAL, UK, but it is on the point of commissioning a world-leading continuous cyclotron-driven source, the SINQ at PSI, Switzerland. Looking to the future, yet more powerful pulsed sources are actively under study and the difficult problem of high-power target design (>250 kW) is leading to a new technology for liquid targets. The accelerator designs, although basically classical, require custom-built solutions that are often at the limit of present day accelerator technology.

  8. Neutron spallation sources in Europe

    NASA Astrophysics Data System (ADS)

    Bryant, P. J.

    1996-11-01

    After a brief general and historical discussion, the main design features of spallation sources are described. At the present time, Europe not only has the world-leading pulsed neutron spallation source, the SNS-ISIS at RAL, UK, but it is on the point of commissioning a world-leading continuous cyclotron-driven source, the SINQ at PSI, Switzerland. Looking to the future, yet more powerful pulsed sources are actively under study and the difficult problem of high-power target design (>250 kW) is leading to a new technology for liquid targets. The accelerator designs, although basically classical, require custom-built solutions that are often at the limit of presentday accelerator technology.

  9. FABRICATION OF NEUTRON SOURCES

    DOEpatents

    Birden, J.H.

    1959-01-20

    A method is presented for preparing a more efficient neutron source comprising inserting in a container a quantity of Po-210, inserting B powder coated with either Ag, Pt, or Ni. The container is sealed and then slowly heated to about 450 C to volatilize the Po and effect combination of the coated powder with the Po. The neutron flux emitted by the unit is moritored and the heating step is terminated when the flux reaches a maximum or selected level.

  10. Dose measurements around spallation neutron sources.

    PubMed

    Fragopoulou, M; Stoulos, S; Manolopoulou, M; Krivopustov, M; Zamani, M

    2008-01-01

    Neutron dose measurements and calculations around spallation sources appear to be of great importance in shielding research. Two spallation sources were irradiated by high-energy proton beams delivered by the Nuclotron accelerator (JINR), Dubna. Neutrons produced by the spallation sources were measured by using solid-state nuclear track detectors. In addition, neutron dose was calculated after polyethylene and concrete, using a phenomenological model based on empirical relations applied in high-energy physics. The study provides an analytical and experimental neutron benchmark analysis using the transmission factor and a comparison between the experimental results and calculations. PMID:18957519

  11. Coded source neutron imaging

    SciTech Connect

    Bingham, Philip R; Santos-Villalobos, Hector J

    2011-01-01

    Coded aperture techniques have been applied to neutron radiography to address limitations in neutron flux and resolution of neutron detectors in a system labeled coded source imaging (CSI). By coding the neutron source, a magnified imaging system is designed with small spot size aperture holes (10 and 100 m) for improved resolution beyond the detector limits and with many holes in the aperture (50% open) to account for flux losses due to the small pinhole size. An introduction to neutron radiography and coded aperture imaging is presented. A system design is developed for a CSI system with a development of equations for limitations on the system based on the coded image requirements and the neutron source characteristics of size and divergence. Simulation has been applied to the design using McStas to provide qualitative measures of performance with simulations of pinhole array objects followed by a quantitative measure through simulation of a tilted edge and calculation of the modulation transfer function (MTF) from the line spread function. MTF results for both 100um and 10um aperture hole diameters show resolutions matching the hole diameters.

  12. Laser generated neutron source for neutron resonance spectroscopy

    SciTech Connect

    Higginson, D. P.; Bartal, T.; McNaney, J. M.; Swift, D. C.; Hey, D. S.; Le Pape, S.; Mackinnon, A.; Kodama, R.; Tanaka, K. A.; Mariscal, D.; Beg, F. N.; Nakamura, H.; Nakanii, N.

    2010-10-15

    A neutron source for neutron resonance spectroscopy has been developed using high-intensity, short-pulse lasers. This technique will allow robust measurement of interior ion temperature of laser-shocked materials and provide insight into material equation of state. The neutron generation technique uses laser-accelerated protons to create neutrons in LiF through (p,n) reactions. The incident proton beam has been diagnosed using radiochromic film. This distribution is used as the input for a (p,n) neutron prediction code which is validated with experimentally measured neutron yields. The calculation infers a total fluence of 1.8x10{sup 9} neutrons, which are expected to be sufficient for neutron resonance spectroscopy temperature measurements.

  13. Proton acceleration in neutron star magnetospheres

    NASA Technical Reports Server (NTRS)

    Smith, I. A.; Katz, J. I.; Diamond, P. H.

    1992-01-01

    To explain the emission of TeV and PeV gamma rays from accreting X-ray binary sources, protons must be accelerated to several times the gamma-ray energy. It is shown here that at certain times, the plasma in the accretion column of the neutron star may form a deep enough pool that the top portion becomes unstable to convective motions in spite of the strong magnetic field. The resulting turbulence produces fluctuations in the strength of the magnetic field that travel up the accretion column, taking energy out to the region of the energetic protons. The protons resonantly absorb this energy and are accelerated to high energies. Including the synchrotron radiation losses of the protons, it is shown that they can be accelerated to energies that are high enough to explain the gamma-ray observations.

  14. New sources and instrumentation for neutron science

    NASA Astrophysics Data System (ADS)

    Gil, Alina

    2011-04-01

    Neutron-scattering research has a lot to do with our everyday lives. Things like medicine, food, electronics, cars and airplanes have all been improved by neutron-scattering research. Neutron research also helps scientists improve materials used in a multitude of different products, such as high-temperature superconductors, powerful lightweight magnets, stronger, lighter plastic products etc. Neutron scattering is one of the most effective ways to obtain information on both, the structure and the dynamics of condensed matter. Most of the world's neutron sources were built decades ago, and although the uses and demand for neutrons have increased throughout the years, few new sources have been built. The new construction, accelerator-based neutron source, the spallation source will provide the most intense pulsed neutron beams in the world for scientific research and industrial development. In this paper it will be described what neutrons are and what unique properties make them useful for science, how spallation source is designed to produce neutron beams and the experimental instruments that will use those beams. Finally, it will be described how past neutron research has affected our everyday lives and what we might expect from the most exciting future applications.

  15. Development of a sealed-accelerator-tube neutron generator

    PubMed

    Verbeke; Leung; Vujic

    2000-10-01

    Sealed-accelerator-tube neutron generators are being developed in Lawrence Berkeley National Laboratory (LBNL) for applications ranging from neutron radiography to boron neutron capture therapy and neutron activation analysis. The new generation of high-output neutron generators is based on the D-T fusion reaction, producing 14.1-MeV neutrons. The main components of the neutron tube--the ion source, the accelerator and the target--are all housed in a sealed metal container without external pumping. Thick-target neutron yield computations are performed in this paper to estimate the neutron yield of titanium and scandium targets. With an average deuteron beam current of 1 A and an energy of 120 keV, a time-averaged neutron production of approximately 10(14) n/s can be estimated for a tritiated target, for both pulsed and cw operations. In mixed deuteron/triton beam operation, a beam current of 2 A at 150 keV is required for the same neutron output. Recent experimental results on ion sources and accelerator columns are presented and discussed. PMID:11003523

  16. Beam dynamics studies on the 100 MeV/100 kW electron linear accelerator for NSC KIPT neutron source

    NASA Astrophysics Data System (ADS)

    Pei, Shi-Lun; Chi, Yun-Long; Wang, Shu-Hong; Pei, Guo-Xi; Zhou, Zu-Sheng; Hou, Mi; Mykola, Ayzatskiy; Ivan, Karnaukhov; Volodymyr, Kushnir; Viktor, Mytrochenko; Andrey, Zelinsky

    2012-07-01

    We designed a 100 MeV/100 kW electron linear accelerator for NSC KIPT, which will be used to drive a neutron source on the basis of subcritical assembly. Beam dynamics studies have been conducted to reach the design requirements (E = 100 MeV, P = 100 kW, dE/E < 1% for 99% particles). In this paper, we will present the progress of the design and the dynamic simulation results. For high intensity and long beam pulse linear accelerators, the BBU effect is one big issue; special care has been taken in the accelerating structure design. To satisfy the energy spread requirement at the linac exit, the particles with large energy difference from the synchronous particle should be eliminated at a low energy stage to ease the design of the collimation system and radiation shielding. A dispersion free chicane with 4 bending magnets is introduced downstream of the 1st accelerating section; the unwanted particles will be collimated there.

  17. Finite element analysis and frequency shift studies for the bridge coupler of the coupled cavity linear accelerator of the spallation neutron source.

    SciTech Connect

    Chen, Z.

    2001-01-01

    The Spallation Neutron Source (SNS) is an accelerator-based neutron scattering research facility. The linear accelerator (linac) is the principal accelerating structure and divided into a room-temperature linac and a superconducting linac. The normal conducting linac system that consists of a Drift Tube Linac (DTL) and a Coupled Cavity Linac (CCL) is to be built by Los Alamos National Laboratory. The CCL structure is 55.36-meters long. It accelerates H- beam from 86.8 Mev to 185.6 Mev at operating frequency of 805 MHz. This side coupled cavity structure has 8 cells per segment, 12 segments and 11 bridge couplers per module, and 4 modules total. A 5-MW klystron powers each module. The number 3 and number 9 bridge coupler of each module are connected to the 5-MW RF power supply. The bridge coupler with length of 2.5 {beta}{gamma} is a three-cell structure and located between the segments and allows power flow through the module. The center cell of each bridge coupler is excited during normal operation. To obtain a uniform electromagnetic filed and meet the resonant frequency shift, the RF induced heat must be removed. Thus, the thermal deformation and frequency shift studies are performed via numerical simulations in order to have an appropriate cooling design and predict the frequency shift under operation. The center cell of the bridge coupler also contains a large 4-inch slug tuner and a tuning post that used to provide bulk frequency adjustment and field intensity adjustment, so that produce the proper total field distribution in the module assembly.

  18. An accelerator-based epithermal photoneutron source for BNCT

    SciTech Connect

    Nigg, D.W.; Mitchell, H.E.; Harker, Y.D.; Yoon, W.Y.

    1995-11-01

    Therapeutically-useful epithermal-neutron beams for BNCT are currently generated by nuclear reactors. Various accelerator-based neutron sources for BNCT have been proposed and some low intensity prototypes of such sources, generally featuring the use of proton beams and beryllium or lithium targets have been constructed. This paper describes an alternate approach to the realization of a clinically useful accelerator-based source of epithermal neutrons for BNCT that reconciles the often conflicting objectives of target cooling, neutron beam intensity, and neutron beam spectral purity via a two stage photoneutron production process.

  19. Optimization of neutron source

    SciTech Connect

    Hooper, E.B.

    1993-11-09

    I consider here the optimization of the two component neutron source, allowing beam species and energy to vary. A simple model is developed, based on the earlier publications, that permits the optimum to be obtained simply. The two component plasma, with one species of hot ion (D{sup +} or T{sup +}) and the complementary species of cold ion, is easy to analyze in the case of a spatially uniform cold plasma, as to good approximation the total number of hot ions is important but not their spatial distribution. Consequently, the optimization can ignore spatial effects. The problem of a plasma with both types of hot ions and cold ions is rather more difficult, as the neutron production by hot-hot interactions is sensitive to their spatial distributions. Consequently, consideration of this problem will be delayed to a future memorandum. The basic model is that used in the published articles on the two-component, beam-plasma mirror source. I integrate the Fokker-Planck equation analytically, obtaining good agreement with previous numerical results. This simplifies the optimization, by providing a functional form for the neutron production. The primary result is expressed in terms of the power efficiency: watts of neutrons/watts of primary power. The latter includes the positive ion neutralization efficiency. At 150 keV, the present model obtains an efficiency of 0.66%, compared with 0.53% of the earlier calculation.

  20. Unconventional neutron sources for oil well logging

    NASA Astrophysics Data System (ADS)

    Frankle, C. M.; Dale, G. E.

    2013-09-01

    Americium-Beryllium (AmBe) radiological neutron sources have been widely used in the petroleum industry for well logging purposes. There is strong desire on the part of various governmental and regulatory bodies to find alternate sources due to the high activity and small size of AmBe sources. Other neutron sources are available, both radiological (252Cf) and electronic accelerator driven (D-D and D-T). All of these, however, have substantially different neutron energy spectra from AmBe and thus cause significantly different responses in well logging tools. We report on simulations performed using unconventional sources and techniques to attempt to better replicate the porosity and carbon/oxygen ratio responses a well logging tool would see from AmBe neutrons. The AmBe response of these two types of tools is compared to the response from 252Cf, D-D, D-T, filtered D-T, and T-T sources.

  1. Cyclotron-based neutron source for BNCT

    SciTech Connect

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K.; Tanaka, H.; Sakurai, Y.; Maruhashi, A.

    2013-04-19

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation and treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8 Multiplication-Sign 109 neutrons/cm{sup 2}/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with {sup 10}B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  2. Cyclotron-based neutron source for BNCT

    NASA Astrophysics Data System (ADS)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K.; Tanaka, H.; Sakurai, Y.; Maruhashi, A.

    2013-04-01

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation & treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8×109 neutrons/cm2/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with 10B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  3. The Frankfurt neutron source FRANZ

    NASA Astrophysics Data System (ADS)

    Alzubaidi, Suha; Bartz, Ulrich; Basten, Markus; Bechtold, Alexander; Chau, Long Phi; Claessens, Christine; Dinter, Hannes; Droba, Martin; Fix, Christopher; Hähnel, Hendrik; Heilmann, Manuel; Hinrichs, Ole; Huneck, Simon; Klump, Batu; Lotz, Marcel; Mäder, Dominik; Meusel, Oliver; Noll, Daniel; Nowottnick, Tobias; Obermayer, Marcus; Payir, Onur; Petry, Nils; Podlech, Holger; Ratzinger, Ulrich; Schempp, Alwin; Schmidt, Stefan; Schneider, Philipp; Seibel, Anja; Schwarz, Malte; Schweizer, Waldemar; Volk, Klaus; Wagner, Christopher; Wiesner, Christoph

    2016-05-01

    A 2MeV proton beam will produce a quasi-Maxwellian neutron spectrum of around 30 keV by the 7Li(p, n)7Be reaction. The experiments are mainly focused on the measurement of differential neutron capture cross sections relevant for the astrophysical s-process in nuclear synthesis. Moreover, proton capture cross sections for the astrophysical p-process can be measured directly with the proton beam. For an efficient time of flight measurement of the neutron energies along the 0.7 m long drift from the Li-target to the sample, 1ns short, intense proton pulses are needed at the target. Additionally, to reach 107 n/cm2/s at the sample, a pulse repetition rate of 250 kHz is intended. After completion and successful running in, FRANZ will become a user facility with internal and external users. The 120 kV injector terminal and the 200mA proton source as well as the low-energy beam transport section and the FRANZ cave have been realized successfully. The 1.9 MV RF accelerator consists of a combined 4-Rod-RFQ/IH-DTL-resonator and is in the RF tuning and power testing phase. The 2 MeV transport and rebuncher section is ready for installation. In a first step FRANZ will offer experimental areas for neutron activation experiments and for proton beam experiments, as mentioned above. From the accelerator physics point of view, FRANZ will be an excellent facility for high current beam investigations and for beam wall interaction studies.

  4. In-phantom characterisation studies at the Birmingham Accelerator-Generated epIthermal Neutron Source (BAGINS) BNCT facility.

    PubMed

    Culbertson, Christopher N; Green, Stuart; Mason, Anna J; Picton, David; Baugh, Gareth; Hugtenburg, Richard P; Yin, Zaizhe; Scott, Malcolm C; Nelson, John M

    2004-11-01

    A broad experimental campaign to validate the final epithermal neutron beam design for the BNCT facility constructed at the University of Birmingham concluded in November 2003. The final moderator and facility designs are overviewed briefly, followed by a summary of the dosimetric methods and presentation of a small subset of the results from this campaign. The dual ionisation chamber technique was used together with foil activation to quantify the fast neutron, photon, and thermal neutron beam dose components in a large rectangular phantom exposed to the beam with a 12 cm diameter beam delimiter in place. After application of a normalisation factor, dose measurements agree with in-phantom MCNP4C predictions within 10% for the photon dose, within 10% for thermal neutron dose, and within 25% for the proton recoil dose along the main beam axis. PMID:15308136

  5. A Sealed-Accelerator-Tube Neutron Generator for Boron Neutron Capture Therapy Application

    SciTech Connect

    Leung, K.-N.; Leung, K.N.; Lee, Y.; Verbeke, J.M.; Vurjic, J.; Williams, M.D.; Wu, L.K.; Zahir, N.

    1998-06-01

    Radio-frequency (RF) driven ion sources are being developed in Lawrence Berkeley National Laboratory (LBNL) for sealed-accelerator-tube neutron generator applications. By using a 2.5-cm-diameter RF-driven multicusp source and a computer designed 100 keV accelerator column, peak extractable hydrogen current exceeding 1 A from a 3-mm-diameter aperture, together with H{sup +} yields over 94% have been achieved. These experimental findings together with recent moderator design will enable one to develop compact 14 MeV neutron generators based on the D-T fusion reaction. In this new neutron generator, the ion source, the accelerator and the target are all housed in a sealed metal container without pumping. With a 120 keV and 1 A deuteron beam, it is estimated that a treatment time of {approx} 45 minutes is needed for boron neutron capture therapy.

  6. Neutron Scattering Simulations at the University of Kentucky Accelerator Laboratory

    NASA Astrophysics Data System (ADS)

    Nguyen, Thienan; Jackson, Daniel; Hicks, S. F.; Rice, Ben; Vanhoy, J. R.

    2015-10-01

    The Monte-Carlo N-Particle Transport code (MCNP) has many applications ranging from radiography to reactor design. It has particle interaction capabilities, making it useful for simulating neutron collisions on surfaces of varying compositions. The neutron flux within the accelerator complex at the University of Kentucky was simulated using MCNP. With it, the complex's capabilities to contain and thermalize 7 MeV neutrons produced via 2H(d,n)3He source reaction to an acceptable level inside the neutron hall and adjoining rooms were analyzed. This will aid in confirming the safety of researchers who are working in the adjacent control room. Additionally, the neutron transport simulation was used to analyze the impact of the collimator copper shielding on various detectors located around the neutron scattering hall. The purpose of this was to attempt to explain any background neutrons that are observed at these detectors. The simulation shows that the complex performs very well with regards to neutron containment and thermalization. Also, the tracking information for the paths taken by the neutrons show that most of the neutrons' lives are spent inside the neutron hall. Finally, the neutron counts were analyzed at the positions of the neutron monitor detectors located at 90 and 45 degrees relative to the incident beam direction. This project was supported in part by the DOE NEUP Grant NU-12-KY-UK-0201-05 and the Donald A. Cowan Physics Institute at the University of Dallas.

  7. Fission fragment driven neutron source

    DOEpatents

    Miller, Lowell G.; Young, Robert C.; Brugger, Robert M.

    1976-01-01

    Fissionable uranium formed into a foil is bombarded with thermal neutrons in the presence of deuterium-tritium gas. The resulting fission fragments impart energy to accelerate deuterium and tritium particles which in turn provide approximately 14 MeV neutrons by the reactions t(d,n).sup.4 He and d(t,n).sup.4 He.

  8. Intense Pulsed Neutron Emission from a Compact Pyroelectric Driven Accelerator

    SciTech Connect

    Tang, V; Meyer, G; Falabella, S; Guethlein, G; Sampayan, S; Kerr, P; Rusnak, B; Morse, J

    2008-10-08

    Intense pulsed D-D neutron emission with rates >10{sup 10} n/s during the pulse, pulse widths of {approx}100's ns, and neutron yields >10 k per pulse are demonstrated in a compact pyroelectric accelerator. The accelerator consists of a small pyroelectric LiTaO{sub 3} crystal which provides the accelerating voltage and an independent compact spark plasma ion source. The crystal voltage versus temperature is characterized and compare well with theory. Results show neutron output per pulse that scales with voltage as V{approx}1.7. These neutron yields match a simple model of the system at low voltages but are lower than predicted at higher voltages due to charge losses not accounted for in the model. Interpretation of the data against modeling provides understanding of the accelerator and in general pyroelectric LiTaO{sub 3} crystals operated as charge limited negative high voltage targets. The findings overall serve as the proof-of-principle and basis for pyroelectric neutron generators that can be pulsed, giving peak neutron rates orders of magnitude greater than previous work, and notably increase the potential applications of pyroelectric based neutron generators.

  9. Linear induction accelerators for fusion and neutron production

    SciTech Connect

    Barletta, W.A. |

    1993-08-01

    Linear induction accelerators (LIA) with pulsed power drives can produce high energy, intense beams or electrons, protons, or heavy ions with megawatts of average power. The continuing development of highly reliable LIA components permits the use such accelerators as cost-effective beam sources to drive fusion pellets with heavy ions, to produce intense neutron fluxes using proton beams, and to generate with electrons microwave power to drive magnetic fusion reactors and high gradient, rf-linacs.

  10. Hybrid photoneutron source optimization for electron accelerator-based BNCT

    NASA Astrophysics Data System (ADS)

    Rahmani, F.; Shahriari, M.

    2010-06-01

    Boron Neutron Capture Therapy (BNCT) is being studied as a possible radiotherapic treatment for some cancer types. Neutron energy for penetrating into tissue should be in the epithermal range. Different methods are used for neutron production. Electron accelerators are an alternative way for producing neutrons in electron-photon-neutron processes. Optimization of electron/photon and photoneutron targets calculations with respect to electron energy, dimension (radius and thickness) and neutron yield were done by MCNPX Monte Carlo code. According to the results, a hybrid photoneutron source including BeD 2 and Tungsten has been introduced.

  11. Pulsed neutron sources for condensed-matter research

    SciTech Connect

    Price, D.L.

    1980-01-01

    The efforts around the world to provide higher neutron intensities are now focussed on accelerator-driven spallation sources in which neutrons are produced by bombardment of heavy metal targets with high energy protons. Spallation sources can be pulsed or quasi-continuous depending on the nature of the proton accelerator. Pulsed spallation sources, based on rapid cycling synchrotrons or storage rings, are especially attractive since a moderate average proton current (10/sup -5/ - 10/sup -3/A) can produce high instantaneous neutron intensities which can be used with time-of-flight methods to provide powerful neutron spectrometers.

  12. The Jülich high-brilliance neutron source project

    NASA Astrophysics Data System (ADS)

    Rücker, U.; Cronert, T.; Voigt, J.; Dabruck, J. P.; Doege, P.-E.; Ulrich, J.; Nabbi, R.; Beßler, Y.; Butzek, M.; Büscher, M.; Lange, C.; Klaus, M.; Gutberlet, T.; Brückel, T.

    2016-01-01

    With the construction of the European Spallation Source ESS, the European neutron user community is looking forward to the brightest source worldwide. At the same time there is an ongoing concentration of research with neutrons to only a few but very powerful neutron facilities. Responding to this situation the Jülich Centre for Neutron Science has initiated a project for a compact accelerator driven high-brilliance neutron source, optimized for neutron scattering on small samples and to be realized at reasonable costs. The project deals with the optimization of potential projectiles, target and moderator concepts, versatile accelerator systems, cold sources, beam extraction systems and optimized instrumentation. A brief outline of the project, the achievements already reached, will be presented, as well as a vision for the future neutron landscape in Europe.

  13. Neutron diffraction on pulsed sources

    NASA Astrophysics Data System (ADS)

    Aksenov, V. L.; Balagurov, A. M.

    2016-03-01

    The current capabilities of and major scientific problems solved by time-of-flight neutron diffraction are reviewed. The reasons for the rapid development of the method over the last two decades have been mainly the emergence of third-generation pulsed sources with a megawatt time-averaged power and advances in neutron optical devices and detector systems. The paper discusses some historical aspects of time-of-flight neutron diffraction and examines the contribution to this method from F L Shapiro, the centennial of whose birth was celebrated in 2015. The state of the art with respect to neutron sources for studies on extracted beams is reviewed in a special section.

  14. Absolute determination of the neutron source yield using melamine as a neutron detector

    NASA Astrophysics Data System (ADS)

    Ciechanowski, M.; Bolewski, A., Jr.; Kreft, A.

    2015-01-01

    A new approach to absolute determination of the neutron source yield is presented. It bases on the application of melamine (C3H6N6) to neutron detection combined with Monte Carlo simulations of neutron transport. Melamine has the ability to detect neutrons via 14N(n, p)14C reaction and subsequent determination of 14C content. A cross section for this reaction is relatively high for thermal neutrons (1.827 b) and much lower for fast neutrons. A concentration of 14C nuclei created in the irradiated sample of melamine can be reliably measured with the aid of the accelerator mass spectrometry (AMS). The mass of melamine sufficient for this analysis is only 10 mg. Neutron detection is supported by Monte Carlo simulations of neutron transport carried out with the use of MCNP-4C code. These simulations are aimed at computing the probability of 14C creation in the melamine sample per the source neutron. The result of AMS measurements together with results of MCNP calculations enable us to determine the number of neutrons emitted from the source during the irradiation of melamine. The proposed method was applied for determining the neutron emission from a commercial 252Cf neutron source which was independently calibrated. The measured neutron emission agreed with the certified one within uncertainty limits. The relative expanded uncertainty (k=2) of the absolute neutron source yield determination was estimated at 2.6%. Apart from calibration of radionuclide neutron sources the proposed procedure could facilitate absolute yield measurements for more complex sources. Potential applications of this methodology as it is further developed include diagnostics of inertial confinement fusion and plasma-focus experiments, calibration of neutron measurement systems at tokamaks and accelerator-based neutron sources as well as characterization of neutron fields generated in large particle detectors during collisions of hadron beams.

  15. Compact neutron source development at LBNL

    SciTech Connect

    Reijonen, Jani; Lou, Tak Pui; Tolmachoff, Bryan; Leung, K.N.

    2001-07-25

    A compact neutron generator based on D-D or D-T fusion reactions is being developed at the Lawrence Berkeley National Laboratory. The deuterium or tritium ions are produced in a radio-frequency (RF) driven multicusp plasma source. Seven beamlets are extracted and are accelerated to energy of 100 keV by means of a three-electrode electrostatic accelerator column. The ion beam then impinges on a titanium coated copper target where either the 2.4 MeV D-D or 14 MeV D-T neutrons are generated by fusion reaction. The development of the neutron tube is divided into three phases. First, the accelerator column is operated at hydrogen beam intensity of 15 mA. Second phase consists of deuterium beam runs at pulsed, low duty cycle 150 mA operation. The third phase consists of deuterium or tritium operation at 1.5 A beam current. Phase one is completed and the results of hydrogen beam testing are discussed. Low duty cycle 150 mA deuterium operation is being investigated. Neutron flux will be measured. Finally the phase three operation and the advance neutron generator designs are described.

  16. Compact neutron source development at LBNL

    NASA Astrophysics Data System (ADS)

    Reijonen, Jani; Lou, Tak P.; Tolmachoff, Bryan; Leung, Ka-Ngo

    2001-12-01

    A compact neutron generator based on D-D or D-T fusion reactions is being developed at the Lawrence Berkeley National laboratory. The deuterium or tritium ions are produced in a radio-frequency (RF) driven multicusp plasma source. Seven beamlets are extracted and are accelerated to energy of 100 keV by means of a three-electrode electrostatic accelerator column. The ion beam then impinges on a titanium coated copper target where either the 2.4 MeV D-D or 13 MeV D-T neutrons are generated by fusion reaction. The development of the neutron tube is divided into three phases. First, the accelerator column is operated at hydrogen beam intensity of 15 mA. Second phase consists of deuterium beam runs at pulsed, low duty cycle 150 mA operation. The third phase consists of deuterium or tritium operation at 1.5 A beam current. Phase one is completed and the results of hydrogen beam testing are discussed. Low duty cycle 150 mA deuterium operation is being investigated. Neutron flux will be measured. Finally the phase three operation and the advance neutron generator designs are described.

  17. An MCNPX accelerator beam source

    SciTech Connect

    Durkee, Joe W.; Elson, Jay S.; Jason, Andrew; Johns, Russell C.; Waters, Laurie S.

    2009-06-04

    MCNPX is a powerful Monte Carlo code that can be used to conduct sophisticated radiation-transport simulations involving complex physics and geometry. Although MCNPX possesses a wide assortment of standardized modeling tools, there are instances in which a user's needs can eclipse existing code capabilities. Fortunately, although it may not be widely known, MCNPX can accommodate many customization needs. In this article, we demonstrate source-customization capability for a new SOURCE subroutine as part of our development to enable simulations involving accelerator beams for active-interrogation studies. Simulation results for a muon beam are presented to illustrate the new accelerator-source capability.

  18. Crystal Driven Neutron Source: A New Paradigm for Miniature Neutron Sources

    SciTech Connect

    Tang, V; Morse, J; Meyer, G; Falabella, S; Guethlein, G; Kerr, P; Park, H G; Rusnak, B; Sampayan, S; Schmid, G; Spadaccini, C; Wang, L

    2008-08-08

    Neutron interrogation techniques have specific advantages for detection of hidden, shielded, or buried threats over other detection modalities in that neutrons readily penetrate most materials providing backscattered gammas indicative of the elemental composition of the potential threat. Such techniques have broad application to military and homeland security needs. Present neutron sources and interrogation systems are expensive and relatively bulky, thereby making widespread use of this technique impractical. Development of a compact, high intensity crystal driven neutron source is described. The crystal driven neutron source approach has been previously demonstrated using pyroelectric crystals that generate extremely high voltages when thermal cycled [1-4]. Placement of a sharpened needle on the positively polarized surface of the pyroelectric crystal results in sufficient field intensification to field ionize background deuterium molecules in a test chamber, and subsequently accelerate the ions to energies in excess of {approx}100 keV, sufficient for either D-D or D-T fusion reactions with appropriate target materials. Further increase in ion beam current can be achieved through optimization of crystal thermal ramping, ion source and crystal accelerator configuration. The advantage of such a system is the compact size along with elimination of large, high voltage power supplies. A novel implementation discussed incorporates an independently controlled ion source in order to provide pulsed neutron operation having microsecond pulse width.

  19. Crystal Driven Neutron Source: A New Paradigm for Miniature Neutron Sources

    NASA Astrophysics Data System (ADS)

    Tang, V.; Morse, J.; Meyer, G.; Falabella, S.; Guethlein, G.; Kerr, P.; Park, H. G.; Rusnak, B.; Sampayan, S.; Schmid, G.; Spadaccini, C.; Wang, L.

    2009-03-01

    Neutron interrogation techniques have specific advantages for detection of hidden, shielded, or buried threats over other detection modalities in that neutrons readily penetrate most materials providing backscattered gammas indicative of the elemental composition of the potential threat. Such techniques have broad application to military and homeland security needs. Present neutron sources and interrogation systems are expensive and relatively bulky, thereby making widespread use of this technique impractical. Development of a compact, high intensity crystal driven neutron source is described. The crystal driven neutron source approach has been previously demonstrated using pyroelectric crystals that generate extremely high voltages when thermal cycled [1-4]. Placement of a sharpened needle on the positively polarized surface of the pyroelectric crystal results in sufficient field intensification to field ionize background deuterium molecules in a test chamber, and subsequently accelerate the ions to energies in excess of ˜100 keV, sufficient for either D-D or D-T fusion reactions with appropriate target materials. Further increase in ion beam current can be achieved through optimization of crystal thermal ramping, ion source and crystal accelerator configuration. The advantage of such a system is the compact size along with elimination of large, high voltage power supplies. A novel implementation discussed incorporates an independently controlled ion source in order to provide pulsed neutron operation having microsecond pulse width.

  20. Research on fusion neutron sources

    NASA Astrophysics Data System (ADS)

    Gryaznevich, M. P.

    2012-06-01

    The use of fusion devices as powerful neutron sources has been discussed for decades. Whereas the successful route to a commercial fusion power reactor demands steady state stable operation combined with the high efficiency required to make electricity production economic, the alternative approach to advancing the use of fusion is free of many of complications connected with the requirements for economic power generation and uses the already achieved knowledge of Fusion physics and developed Fusion technologies. "Fusion for Neutrons" (F4N), has now been re-visited, inspired by recent progress achieved on comparably compact fusion devices, based on the Spherical Tokamak (ST) concept. Freed from the requirement to produce much more electricity than used to drive it, a fusion neutron source could be efficiently used for many commercial applications, and also to support the goal of producing energy by nuclear power. The possibility to use a small or medium size ST as a powerful or intense steady-state fusion neutron source (FNS) is discussed in this paper in comparison with the use of traditional high aspect ratio tokamaks. An overview of various conceptual designs of compact fusion neutron sources based on the ST concept is given and they are compared with a recently proposed Super Compact Fusion Neutron Source (SCFNS), with major radius as low as 0.5 metres but still able to produce several MW of neutrons in a steady-state regime.

  1. Compact ion accelerator source

    SciTech Connect

    Schenkel, Thomas; Persaud, Arun; Kapadia, Rehan; Javey, Ali

    2014-04-29

    An ion source includes a conductive substrate, the substrate including a plurality of conductive nanostructures with free-standing tips formed on the substrate. A conductive catalytic coating is formed on the nanostructures and substrate for dissociation of a molecular species into an atomic species, the molecular species being brought in contact with the catalytic coating. A target electrode placed apart from the substrate, the target electrode being biased relative to the substrate with a first bias voltage to ionize the atomic species in proximity to the free-standing tips and attract the ionized atomic species from the substrate in the direction of the target electrode.

  2. Physics design of a cold neutron source for KIPT neutron source facility.

    SciTech Connect

    Zhong, Z.; Gohar, Y.; Kellogg, R.; Nuclear Engineering Division

    2009-02-17

    Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the conceptual design development of a neutron source facility. It is based on the use of an electron accelerator driven subcritical (ADS) facility with low enriched uranium fuel, using the existing electron accelerators at KIPT of Ukraine [1]. The neutron source of the subcritical assembly is generated from the interaction of 100-KW electron beam, which has a uniform spatial distribution and the electron energy in the range of 100 to 200 MeV, with a natural uranium target [2]. The main functions of the facility are the production of medical isotopes and the support of the Ukraine nuclear power industry. Neutron beam experiments and material studies are also included. Over the past two-three decades, structures with characteristic lengths of 100 {angstrom} and correspondingly smaller vibrational energies have become increasingly important for both science and technology [3]. The characteristic dimensions of the microstructures can be well matched by neutrons with longer vibrational wavelength and lower energy. In the accelerator-driven subcritical facility, most of the neutrons are generated from fission reactions with energy in the MeV range. They are slowed down to the meV energy range through scattering reactions in the moderator and reflector materials. However, the fraction of neutrons with energies less than 5 meV in a normal moderator spectrum is very low because of up-scattering caused by the thermal motion of moderator or reflector molecules. In order to obtain neutrons with energy less than 5 meV, cryogenically cooled moderators 'cold neutron sources' should be used to slow down the neutrons. These cold moderators shift the neutron energy spectrum down because the thermal motion of moderator molecules as well as the up-scattering is very small, which provides large gains in intensity of low energy neutrons, E < 5 meV. The

  3. Linac-driven spallation-neutron source

    SciTech Connect

    Jason, A.J.

    1995-05-01

    Strong interest has arisen in accelerator-driven spallation-neutron sources that surpass existing facilities (such as ISIS at Rutherford or LANSCE at Los Alamos) by more than an order of magnitude in beam power delivered to the spallation target. The approach chosen by Los Alamos (as well as the European Spallation Source) provides the full beam energy by acceleration in a linac as opposed to primary acceleration in a synchrotron or other circular device. Two modes of neutron production are visualized for the source. A short-pulse mode produces 1 MW of beam power (at 60 pps) in pulses, of length less than 1 ms, by compression of the linac macropulse through multi-turn injection in an accumulator ring. A long-pulse mode produces a similar beam power with 1-ms-long pulses directly applied to a target. This latter mode rivals the performance of existing reactor facilities to very low neutron energies. Combination with the short-pulse mode addresses virtually all applications.

  4. The tokamak as a neutron source

    SciTech Connect

    Hendel, H.W.; Jassby, D.L.

    1989-11-01

    This paper describes the tokamak in its role as a neutron source, with emphasis on experimental results for D-D neutron production. The sections summarize tokamak operation, sources of fusion and non-fusion neutrons, principal neutron detection methods and their calibration, neutron energy spectra and fluxes outside the tokamak plasma chamber, history of neutron production in tokamaks, neutron emission and fusion power gain from JET and TFTR (the largest present-day tokamaks), and D-T neutron production from burnup of D-D tritons. This paper also discusses the prospects for future tokamak neutron production and potential applications of tokamak neutron sources. 100 refs., 16 figs., 4 tabs.

  5. Materials for spallation neutron sources

    SciTech Connect

    Sommer, W.F.; Daemen, L.L.

    1996-03-01

    The Workshop on Materials for Spallation Neutron Sources at the Los Alamos Neutron Science Center, February 6 to 10, 1995, gathered scientists from Department of Energy national laboratories, other federal institutions, universities, and industry to discuss areas in which work is needed, successful designs and use of materials, and opportunities for further studies. During the first day of the workshop, speakers presented overviews of current spallation neutron sources. During the next 3 days, seven panels allowed speakers to present information on a variety of topics ranging from experimental and theoretical considerations on radiation damage to materials safety issues. An attempt was made to identify specific problems that require attention within the context of spallation neutron sources. This proceedings is a collection of summaries from the overview sessions and the panel presentations.

  6. High-Current Experiments for Accelerator-Based Neutron Capture Therapy Applications

    SciTech Connect

    Gierga, D.P.; Klinkowstein, R.E.; Hughey, B.H.; Shefer, R.E.; Yanch, J.C.; Blackburn, B.W.

    1999-06-06

    Several accelerator-based neutron capture therapy applications are under development. These applications include boron neutron capture therapy for glioblastoma multiform and boron neutron capture synovectomy (BNCS) for rheumatoid arthritis. These modalities use accelerator-based charged-particle reactions to create a suitable neutron source. Neutrons are produced using a high-current, 2-MV terminal tandem accelerator. For these applications to be feasible, high accelerator beam currents must be routinely achievable. An effort was undertaken to explore the operating regime of the accelerator in the milliampere range. In preparation for high-current operation of the accelerator, computer simulations of charged-particle beam optics were performed to establish high-current operating conditions. Herein we describe high beam current simulations and high beam current operation of the accelerator.

  7. Monitoring of D-T accelerator neutron output in a PGNAA system using silicon carbide detectors

    NASA Astrophysics Data System (ADS)

    Dulloo, Abdul R.; Ruddy, Frank H.; Seidel, John G.; Petrović, Bojan

    2001-07-01

    Silicon carbide (SiC) detectors are being employed to monitor the neutron output of the D-T accelerator in a pulsed Prompt Gamma Neutron Activation Analysis (PGNAA) system. Detection of the source neutrons relies on energetic neutron reactions in the detector material. Experimental testing has been performed to confirm that the detector response is caused by fast neutrons from the accelerator source. Modeling calculations have also been carried out to provide additional verification. Use of the SiC detectors in the PGNAA system is expected to assist in evaluating system performance as well as ensuring accurate data interpretation and analysis.

  8. Accelerator Based Neutron Beams for Neutron Capture Therapy

    SciTech Connect

    Yanch, Jacquelyn C.

    2003-04-11

    The DOE-funded accelerator BNCT program at the Massachusetts Institute of Technology has resulted in the only operating accelerator-based epithermal neutron beam facility capable of generating significant dose rates in the world. With five separate beamlines and two different epithermal neutron beam assemblies installed, we are currently capable of treating patients with rheumatoid arthritis in less than 15 minutes (knee joints) or 4 minutes (finger joints) or irradiating patients with shallow brain tumors to a healthy tissue dose of 12.6 Gy in 3.6 hours. The accelerator, designed by Newton scientific Incorporated, is located in dedicated laboratory space that MIT renovated specifically for this project. The Laboratory for Accelerator Beam Applications consists of an accelerator room, a control room, a shielded radiation vault, and additional laboratory space nearby. In addition to the design, construction and characterization of the tandem electrostatic accelerator, this program also resulted in other significant accomplishments. Assemblies for generating epithermal neutron beams were designed, constructed and experimentally evaluated using mixed-field dosimetry techniques. Strategies for target construction and target cooling were implemented and tested. We demonstrated that the method of submerged jet impingement using water as the coolant is capable of handling power densities of up to 6 x 10(sup 7) W/m(sup 2) with heat transfer coefficients of 10(sup 6)W/m(sup 2)-K. Experiments with the liquid metal gallium demonstrated its superiority compared with water with little effect on the neutronic properties of the epithermal beam. Monoenergetic proton beams generated using the accelerator were used to evaluate proton RBE as a function of LET and demonstrated a maximum RBE at approximately 30-40 keV/um, a finding consistent with results published by other researchers. We also developed an experimental approach to biological intercomparison of epithermal beams and

  9. High intensity, pulsed thermal neutron source

    DOEpatents

    Carpenter, J.M.

    1973-12-11

    This invention relates to a high intensity, pulsed thermal neutron source comprising a neutron-producing source which emits pulses of fast neutrons, a moderator block adjacent to the last neutron source, a reflector block which encases the fast neutron source and the moderator block and has a thermal neutron exit port extending therethrough from the moderator block, and a neutron energy- dependent decoupling reflector liner covering the interior surfaces of the thermal neutron exit port and surrounding all surfaces of the moderator block except the surface viewed by the thermal neutron exit port. (Official Gazette)

  10. A bright neutron source driven by relativistic transparency of solids

    NASA Astrophysics Data System (ADS)

    Roth, M.; Jung, D.; Falk, K.; Guler, N.; Deppert, O.; Devlin, M.; Favalli, A.; Fernandez, J.; Gautier, D. C.; Geissel, M.; Haight, R.; Hamilton, C. E.; Hegelich, B. M.; Johnson, R. P.; Kleinschmidt, A.; Merrill, F.; Schaumann, G.; Schoenberg, K.; Schollmeier, M.; Shimada, T.; Taddeucci, T.; Tybo, J. L.; Wagner, F.; Wender, S. A.; Wilde, C. H.; Wurden, G. A.

    2016-03-01

    Neutrons are a unique tool to alter and diagnose material properties and excite nuclear reactions with a large field of applications. It has been stated over the last years, that there is a growing need for intense, pulsed neutron sources, either fast or moderated neutrons for the scientific community. Accelerator based spallation sources provide unprecedented neutron fluxes, but could be complemented by novel sources with higher peak brightness that are more compact. Lasers offer the prospect of generating a very compact neutron source of high peak brightness that could be linked to other facilities more easily. We present experimental results on the first short pulse laser driven neutron source powerful enough for applications in radiography. For the first time an acceleration mechanism (BOA) based on the concept of relativistic transparency has been used to generate neutrons. This mechanism not only provides much higher particle energies, but also accelerated the entire target volume, thereby circumventing the need for complicated target treatment and no longer limited to protons as an intense ion source. As a consequence we have demonstrated a new record in laser-neutron production, not only in numbers, but also in energy and directionality based on an intense deuteron beam. The beam contained, for the first time, neutrons with energies in excess of 100 MeV and showed pronounced directionality, which makes then extremely useful for a variety of applications. The results also address a larger community as it paves the way to use short pulse lasers as a neutron source. They can open up neutron research to a broad academic community including material science, biology, medicine and high energy density physics as laser systems become more easily available to universities and therefore can complement large scale facilities like reactors or particle accelerators. We believe that this has the potential to increase the user community for neutron research largely.

  11. Application of an ultraminiature thermal neutron monitor for irradiation field study of accelerator-based neutron capture therapy

    PubMed Central

    Ishikawa, Masayori; Tanaka, Kenichi; Endo, Satrou; Hoshi, Masaharu

    2015-01-01

    Phantom experiments to evaluate thermal neutron flux distribution were performed using the Scintillator with Optical Fiber (SOF) detector, which was developed as a thermal neutron monitor during boron neutron capture therapy (BNCT) irradiation. Compared with the gold wire activation method and Monte Carlo N-particle (MCNP) calculations, it was confirmed that the SOF detector is capable of measuring thermal neutron flux as low as 105 n/cm2/s with sufficient accuracy. The SOF detector will be useful for phantom experiments with BNCT neutron fields from low-current accelerator-based neutron sources. PMID:25589504

  12. Optimal Neutron Source & Beam Shaping Assembly for Boron Neutron Capture Therapy

    SciTech Connect

    J. Vujic; E. Greenspan; W.E. Kastenber; Y. Karni; D. Regev; J.M. Verbeke, K.N. Leung; D. Chivers; S. Guess; L. Kim; W. Waldron; Y. Zhu

    2003-04-30

    There were three objectives to this project: (1) The development of the 2-D Swan code for the optimization of the nuclear design of facilities for medical applications of radiation, radiation shields, blankets of accelerator-driven systems, fusion facilities, etc. (2) Identification of the maximum beam quality that can be obtained for Boron Neutron Capture Therapy (BNCT) from different reactor-, and accelerator-based neutron sources. The optimal beam-shaping assembly (BSA) design for each neutron source was also to e obtained. (3) Feasibility assessment of a new neutron source for NCT and other medical and industrial applications. This source consists of a state-of-the-art proton or deuteron accelerator driving and inherently safe, proliferation resistant, small subcritical fission assembly.

  13. Shielding Ddsign and analyses of KIPT neutron source facility.

    SciTech Connect

    Zhong, Z.; Gohar, Y.

    2011-01-01

    Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the conceptual design development of a neutron source facility. An electron accelerator drives a sub-critical facility (ADS) is used for generating the neutron source. The facility will be utilized for performing basic and applied nuclear researches, producing medical isotopes, and training young nuclear specialists. Monte Carlo code MCNPX has been utilized as the major design tool for the design, due to its capability to transport electrons, photons, and neutrons at high energies. However the ADS shielding calculations with MCNPX need enormous computational resources and the small neutron yield per electron makes sampling difficulty for the Monte Carlo calculations. The high energy electrons (E > 100 MeV) generate very high energy neutrons and these neutrons dominant the total radiation dose outside the shield. The radiation dose caused by high energy neutrons is {approx}3-4 orders of magnitude higher than that of the photons. However, the high energy neutron fraction within the total generated neutrons is very small, which increases the sampling difficulty and the required computational time. To solve these difficulties, the user subroutines of MCNPX are utilized to generate a neutron source file, which record the generated neutrons from the photonuclear reactions caused by electrons. This neutron source file is utilized many times in the following MCNPX calculations for weight windows (importance function) generation and radiation dose calculations. In addition, the neutron source file can be sampled multiple times to improve the statistics of the calculated results. In this way the expensive electron transport calculations can be performed once with good statistics for the different ADS shielding problems. This paper presents the method of generating and utilizing the neutron source file by MCNPX for the ADS shielding calculation

  14. Electronic neutron sources for compensated porosity well logging

    SciTech Connect

    Chen, Allan Xi; Antolak, Arlyn J; Leung, Ka-Ngo

    2012-02-01

    The viability of replacing Americium–Beryllium (Am–Be) radiological neutron sources in compensated porosity nuclear well logging tools with D–T or D–D accelerator-driven neutron sources is explored. The analysis consisted of developing a model for a typical well-logging borehole configuration and computing the helium-3 detector response to varying formation porosities using three different neutron sources (Am–Be, D–D, and D–T). The results indicate that, when normalized to the same source intensity, the use of a D–D neutron source has greater sensitivity for measuring the formation porosity than either an Am–Be or D–T source. The results of the study provide operational requirements that enable compensated porosity well logging with a compact, low power D–D neutron generator, which the current state-of-the-art indicates is technically achievable.

  15. Electronic neutron sources for compensated porosity well logging

    NASA Astrophysics Data System (ADS)

    Chen, A. X.; Antolak, A. J.; Leung, K.-N.

    2012-08-01

    The viability of replacing Americium-Beryllium (Am-Be) radiological neutron sources in compensated porosity nuclear well logging tools with D-T or D-D accelerator-driven neutron sources is explored. The analysis consisted of developing a model for a typical well-logging borehole configuration and computing the helium-3 detector response to varying formation porosities using three different neutron sources (Am-Be, D-D, and D-T). The results indicate that, when normalized to the same source intensity, the use of a D-D neutron source has greater sensitivity for measuring the formation porosity than either an Am-Be or D-T source. The results of the study provide operational requirements that enable compensated porosity well logging with a compact, low power D-D neutron generator, which the current state-of-the-art indicates is technically achievable.

  16. Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy

    SciTech Connect

    Herrera, Maria S.; Gonzalez, Sara J.; Minsky, Daniel M.; Kreiner, Andres J.

    2010-08-04

    Glioblastoma multiforme and metastatic melanoma are frequent brain tumors in adults and presently still incurable diseases. Boron Neutron Capture Therapy (BNCT) is a promising alternative for this kind of pathologies. Accelerators have been proposed for BNCT as a way to circumvent the problem of siting reactors in hospitals and for their relative simplicity and lower cost among other advantages. Considerable effort is going into the development of accelerator-based BNCT neutron sources in Argentina. Epithermal neutron beams will be produced through appropriate proton-induced nuclear reactions and optimized beam shaping assemblies. Using these sources, computational dose distributions were evaluated in a real patient with diagnosed glioblastoma treated with BNCT. The simulated irradiation was delivered in order to optimize dose to the tumors within the normal tissue constraints. Using Monte Carlo radiation transport calculations, dose distributions were generated for brain, skin and tumor. Also, the dosimetry was studied by computing cumulative dose-volume histograms for volumes of interest. The results suggest acceptable skin average dose and a significant dose delivered to tumor with low average whole brain dose for irradiation times less than 60 minutes, indicating a good performance of an accelerator-based BNCT treatment.

  17. Treatment Planning for Accelerator-Based Boron Neutron Capture Therapy

    NASA Astrophysics Data System (ADS)

    Herrera, María S.; González, Sara J.; Minsky, Daniel M.; Kreiner, Andrés J.

    2010-08-01

    Glioblastoma multiforme and metastatic melanoma are frequent brain tumors in adults and presently still incurable diseases. Boron Neutron Capture Therapy (BNCT) is a promising alternative for this kind of pathologies. Accelerators have been proposed for BNCT as a way to circumvent the problem of siting reactors in hospitals and for their relative simplicity and lower cost among other advantages. Considerable effort is going into the development of accelerator-based BNCT neutron sources in Argentina. Epithermal neutron beams will be produced through appropriate proton-induced nuclear reactions and optimized beam shaping assemblies. Using these sources, computational dose distributions were evaluated in a real patient with diagnosed glioblastoma treated with BNCT. The simulated irradiation was delivered in order to optimize dose to the tumors within the normal tissue constraints. Using Monte Carlo radiation transport calculations, dose distributions were generated for brain, skin and tumor. Also, the dosimetry was studied by computing cumulative dose-volume histograms for volumes of interest. The results suggest acceptable skin average dose and a significant dose delivered to tumor with low average whole brain dose for irradiation times less than 60 minutes, indicating a good performance of an accelerator-based BNCT treatment.

  18. Optical polarizing neutron devices designed for pulsed neutron sources

    SciTech Connect

    Takeda, M.; Kurahashi, K.; Endoh, Y.; Itoh, S.

    1997-09-01

    We have designed two polarizing neutron devices for pulsed cold neutrons. The devices have been tested at the pulsed neutron source at the Booster Synchrotron Utilization Facility of the National Laboratory for High Energy Physics. These two devices proved to have a practical use for experiments to investigate condensed matter physics using pulsed cold polarized neutrons.

  19. Facility for fast neutron irradiation tests of electronics at the ISIS spallation neutron source

    SciTech Connect

    Andreani, C.; Pietropaolo, A.; Salsano, A.; Gorini, G.; Tardocchi, M.; Paccagnella, A.; Gerardin, S.; Frost, C. D.; Ansell, S.; Platt, S. P.

    2008-03-17

    The VESUVIO beam line at the ISIS spallation neutron source was set up for neutron irradiation tests in the neutron energy range above 10 MeV. The neutron flux and energy spectrum were shown, in benchmark activation measurements, to provide a neutron spectrum similar to the ambient one at sea level, but with an enhancement in intensity of a factor of 10{sup 7}. Such conditions are suitable for accelerated testing of electronic components, as was demonstrated here by measurements of soft error rates in recent technology field programable gate arrays.

  20. The Spallation Neutron Source Beam Commissioning and Initial Operations

    SciTech Connect

    Henderson, Stuart; Aleksandrov, Alexander V.; Allen, Christopher K.; Assadi, Saeed; Bartoski, Dirk; Blokland, Willem; Casagrande, F.; Campisi, I.; Chu, C.; Cousineau, Sarah M.; Crofford, Mark T.; Danilov, Viatcheslav; Deibele, Craig E.; Dodson, George W.; Feshenko, A.; Galambos, John D.; Han, Baoxi; Hardek, T.; Holmes, Jeffrey A.; Holtkamp, N.; Howell, Matthew P.; Jeon, D.; Kang, Yoon W.; Kasemir, Kay; Kim, Sang-Ho; Kravchuk, L.; Long, Cary D.; McManamy, T.; Pelaia, II, Tom; Piller, Chip; Plum, Michael A.; Pogge, James R.; Purcell, John David; Shea, T.; Shishlo, Andrei P; Sibley, C.; Stockli, Martin P.; Stout, D.; Tanke, E.; Welton, Robert F; Zhang, Y.; Zhukov, Alexander P

    2015-09-01

    The Spallation Neutron Source (SNS) accelerator delivers a one mega-Watt beam to a mercury target to produce neutrons used for neutron scattering materials research. It delivers ~ 1 GeV protons in short (< 1 us) pulses at 60 Hz. At an average power of ~ one mega-Watt, it is the highest-powered pulsed proton accelerator. The accelerator includes the first use of superconducting RF acceleration for a pulsed protons at this energy. The storage ring used to create the short time structure has record peak particle per pulse intensity. Beam commissioning took place in a staged manner during the construction phase of SNS. After the construction, neutron production operations began within a few months, and one mega-Watt operation was achieved within three years. The methods used to commission the beam and the experiences during initial operation are discussed.

  1. China Spallation Neutron Source: Design, R&D, and outlook

    NASA Astrophysics Data System (ADS)

    Wei, Jie; Chen, Hesheng; Chen, Yanwei; Chen, Yuanbo; Chi, Yunlong; Deng, Changdong; Dong, Haiyi; Dong, Lan; Fang, Shouxian; Feng, Ji; Fu, Shinian; He, Lunhua; He, Wei; Heng, Yuekun; Huang, Kaixi; Jia, Xuejun; Kang, Wen; Kong, Xiangcheng; Li, Jian; Liang, Tianjiao; Lin, Guoping; Liu, Zhenan; Ouyang, Huafu; Qin, Qing; Qu, Huamin; Shi, Caitu; Sun, Hong; Tang, Jingyu; Tao, Juzhou; Wang, Chunhong; Wang, Fangwei; Wang, Dingsheng; Wang, Qingbin; Wang, Sheng; Wei, Tao; Xi, Jiwei; Xu, Taoguang; Xu, Zhongxiong; Yin, Wen; Yin, Xuejun; Zhang, Jing; Zhang, Zong; Zhang, Zonghua; Zhou, Min; Zhu, Tao

    2009-02-01

    The China Spallation Neutron Source (CSNS) is an accelerator based multidiscipline user facility planned to be constructed in Dongguan, Guangdong, China. The CSNS complex consists of an negative hydrogen linear accelerator, a rapid cycling proton synchrotron accelerating the beam to 1.6 GeV energy, a solid tungsten target station, and instruments for spallation neutron applications. The facility operates at 25 Hz repetition rate with an initial design beam power of 120 kW and is upgradeable to 500 kW. The primary challenge is to build a robust and reliable user's facility with upgrade potential at a fraction of "world standard" cost. We report the status, design, R&D, and upgrade outlook including applications using spallation neutron, muon, fast neutron, and proton, as well as related programs including medical therapy and accelerator-driven sub-critical reactor (ADS) programs for nuclear waste transmutation.

  2. Synchrotron based spallation neutron source concepts

    SciTech Connect

    Cho, Y.

    1998-07-01

    During the past 20 years, rapid-cycling synchrotrons (RCS) have been used very productively to generate short-pulse thermal neutron beams for neutron scattering research by materials science communities in Japan (KENS), the UK (ISIS) and the US (IPNS). The most powerful source in existence, ISIS in the UK, delivers a 160-kW proton beam to a neutron-generating target. Several recently proposed facilities require proton beams in the MW range to produce intense short-pulse neutron beams. In some proposals, a linear accelerator provides the beam power and an accumulator ring compresses the pulse length to the required {approx} 1 {micro}s. In others, RCS technology provides the bulk of the beam power and compresses the pulse length. Some synchrotron-based proposals achieve the desired beam power by combining two or more synchrotrons of the same energy, and others propose a combination of lower and higher energy synchrotrons. This paper presents the rationale for using RCS technology, and a discussion of the advantages and disadvantages of synchrotron-based spallation sources.

  3. Physics and technology of spallation neutron sources

    NASA Astrophysics Data System (ADS)

    Bauer, G. S.

    2001-05-01

    A substantial body of research is necessary in order to be able to make reliable predictions on the performance and safety of Accelerator Driven Systems (ADS), in particular of their spallation targets. So far, practical experience has resulted from the development of research neutron sources only. Next to fission and fusion, spallation is an efficient process for releasing neutrons from nuclei. Unlike the other two reactions, it is an endothermal process and can, therefore, not be used per se in energy generation. In order to sustain a spallation reaction, an energetic beam of particles, most commonly protons, must be supplied onto a heavy target. Spallation can, however, play an important role as a source of neutrons whose flux can be easily controlled via the driving beam. Although sophisticated Monte Carlo codes exist to compute all aspects of a spallation facility, many features can be understood on the basis of simple physics arguments. Technically a spallation facility is very demanding, not only because a reliable and economic accelerator of high power is needed to drive the reaction, but also, and in particular, because high levels of radiation and heat are generated in the target which are difficult to cope with. Radiation effects in a spallation environment are different from those commonly encountered in a reactor and are probably even more temperature dependent than the latter because of the high gas production rate. A commonly favored solution is the use of molten heavy metal targets. While radiation damage is not a problem in this case, except for the container, other issues need to be considered. R&D carried out for the development of spallation neutron sources will thus be beneficial also directly for ADS.

  4. Neutron emission from fission fragments during acceleration p

    SciTech Connect

    Hinde, D.J.; Charity, R.J.; Foote, G.S.; Leigh, J.R.; Newton, J.O.; Ogaza, S.; Chatterjee, A.

    1984-03-19

    Fission-neutron angular correlations following fusion of /sup 19/F and /sup 232/Th have been measured. Conventional analysis, based on the approximation that post-fission neutrons originate only from fully accelerated fission fragments, gives unexpectedly large numbers of ''prefission'' neutrons. Comparison with the considerably less fissile system /sup 200/Pb gives the first convincing evidence that this approach is inadequate. Consideration of neutron emission from the accelerating fragments gives results consistent with expectations.

  5. Designing accelerator-based epithermal neutron beams for boron neutron capture therapy

    SciTech Connect

    Bleuel, D.L.; Donahue, R.J.; Ludewigt, B.A.; Vujic, J.

    1998-09-01

    The {sup 7}Li(p,n){sup 7}Be reaction has been investigated as an accelerator-driven neutron source for proton energies between 2.1 and 2.6 MeV. Epithermal neutron beams shaped by three moderator materials, Al/AlF{sub 3}, {sup 7}LiF, and D{sub 2}O, have been analyzed and their usefulness for boron neutron capture therapy (BNCT) treatments evaluated. Radiation transport through the moderator assembly has been simulated with the Monte Carlo {ital N}-particle code (MCNP). Fluence and dose distributions in a head phantom were calculated using BNCT treatment planning software. Depth-dose distributions and treatment times were studied as a function of proton beam energy and moderator thickness. It was found that an accelerator-based neutron source with Al/AlF{sub 3} or {sup 7}LiF as moderator material can produce depth-dose distributions superior to those calculated for a previously published neutron beam design for the Brookhaven Medical Research Reactor, achieving up to {approximately}50{percent} higher doses near the midline of the brain. For a single beam treatment, a proton beam current of 20 mA, and a {sup 7}LiF moderator, the treatment time was estimated to be about 40 min. The tumor dose deposited at a depth of 8 cm was calculated to be about 21 Gy-Eq. {copyright} {ital 1998 American Association of Physicists in Medicine.}

  6. Neutron beam characterization at the Intense Pulsed Neutron Source.

    SciTech Connect

    Iverson, E. B.

    1998-05-18

    The Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory is a spallation neutron source dedicated to materials research. Its three cryogenic methane moderators provide twelve neutron beams to fourteen neutron scattering instruments and test facilities. The moderators at IPNS are of cryogenic methane (CH{sub 4}); one of liquid methane at 100 K, and two of solid methane at 30 K. These moderators produce intense beams of both cold and thermal neutrons. The moderators are each of a different physical configuration in order to tailor their performance for the instruments and facilities that operate on the neutron beams. As part of the ongoing operation of IPNS, as well as new enhancements to the target, moderator, and reflector systems, we have performed experiments characterizing the energy and time distribution of neutrons in the various beams. These measurements provide absolutely normalized energy spectra using foil activation techniques joined with time-of-flight measurements, and energy-dependent time distributions using a time-focused crystal analyzer. The IPNS accelerator system delivers 14 {micro}A of 450 MeV protons, in 100 ns pulses at 30 Hz, to a target composed of water-cooled depleted uranium disks. The solid methane ''H'' moderator is 100 by 100 by 45 mm in size, centerline poisoned with 0.25 mg/mm{sup 2} gadolinium, and decoupled from the graphite reflector with 0.5 mm of cadmium. The liquid methane ''F'' moderator, which is viewed from both faces, is also 100 by 100 by 45 mm in size, gadolinium poisoned 16 mm below each of the two viewed surfaces, and decoupled from the graphite reflector with cadmium. The solid methane ''C'' moderator has a re-entrant ''grooved'' geometry. The moderator is 100 by 100 by 80 mm overall, with 40 mm deep 12 mm wide horizontal grooves in the viewed surface. These grooves cover 50% of the viewed surface area. The ''C'' moderator is unpoisoned, but is decoupled from the graphite reflector with 0.5 mm of cadmium.

  7. How to Produce a Reactor Neutron Spectrum Using a Proton Accelerator

    NASA Astrophysics Data System (ADS)

    Burns, K.; Wootan, D.; Gates, R.; Schmitt, B.; Asner, D. M.

    A method for reproducing the neutron energy spectrum present in the core of an operating nuclear reactor using an engineered target in an accelerator proton beam is proposed. The protons interact with a target to create neutrons through various (p,n) type reactions. Spectral tailoring of the emitted neutrons can be used to modify the energy of the generated neutron spectrum to represent various reactor spectra. Through the use of moderators and reflectors, the neutron spectrum can be modified to reproduce many different spectra of interest including spectra in small thermal test reactors, large pressurized water reactors, and fast reactors. The particular application of this methodology is the design of an experimental approach for using an accelerator to measure the betas produced during fission to be used to reduce uncertainties in the interpretation of reactor antineutrino measurements. This approach involves using a proton accelerator to produce a neutron field representative of a power reactor, and using this neutron field to irradiate fission foils of the primary isotopes contributing to fission in the reactor, creating unstable, neutron rich fission products that subsequently beta decay and emit electron antineutrinos. A major advantage of an accelerator neutron source over a neutron beam from a thermal reactor is that the fast neutrons can be slowed down or tailored to approximate various power reactor spectra. An accelerator based neutron source that can be tailored to match various reactor neutron spectra provides an advantage for control in studying how changes in the neutron spectra affect parameters such as the resulting fission product beta spectrum.

  8. How to produce a reactor neutron spectrum using a proton accelerator

    SciTech Connect

    Burns, Kimberly A.; Wootan, David W.; Gates, Robert O.; Schmitt, Bruce E.; Asner, David M.

    2015-01-01

    A method for reproducing the neutron energy spectrum present in the core of an operating nuclear reactor using an engineered target in an accelerator proton beam is proposed. The protons interact with a target to create neutrons through various (p,n) type reactions. Spectral tailoring of the emitted neutrons can be used to modify the energy of the generated neutron spectrum to represent various reactor spectra. Through the use of moderators and reflectors, the neutron spectrum can be modified to reproduce many different spectra of interest including spectra in small thermal test reactors, large pressurized water reactors, and fast reactors. The particular application of this methodology is the design of an experimental approach for using an accelerator to measure the betas produced during fission to be used to reduce uncertainties in the interpretation of reactor antineutrino measurements. This approach involves using a proton accelerator to produce a neutron field representative of a power reactor, and using this neutron field to irradiate fission foils of the primary isotopes contributing to fission in the reactor, creating unstable, neutron rich fission products that subsequently beta decay and emit electron antineutrinos. A major advantage of an accelerator neutron source over a neutron beam from a thermal reactor is that the fast neutrons can be slowed down or tailored to approximate various power reactor spectra. An accelerator based neutron source that can be tailored to match various reactor neutron spectra provides an advantage for control in studying how changes in the neutron spectra affect parameters such as the resulting fission product beta spectrum.

  9. Production and Applications of Neutrons Using Particle Accelerators

    NASA Astrophysics Data System (ADS)

    Chichester, David L.

    2012-06-01

    Advances in neutron science have gone hand in hand with the development of particle accelerators from the beginning of both fields. Early accelerator systems were developed simply to produce neutrons, allowing scientists to study their properties and interactions with matter, but people quickly realized that more tangible uses existed for them. Today, these systems are in use in such diverse applications as mineral assaying, oil well logging, radiography, and explosive detection to name a few. This chapter presents a technical introduction to the different ways particle accelerators are used to produce neutrons, an historical overview of the development of neutron-producing particle accelerators, a description of current industrial accelerator systems, narratives of the industrial fields where neutron-producing particle accelerators are used today, and comments on future trends.

  10. A Bright Neutron Source Driven by a Short Pulse Laser

    NASA Astrophysics Data System (ADS)

    Roth, Markus

    2012-10-01

    Neutrons are a unique tool to alter and diagnose material properties, and to exciting nuclear reactions, for many applications. Accelerator based spallation sources provide high neutron fluxes for research, but there is a growing need for more compact sources with higher peak brightness, whether fast or moderated neutrons. Intense lasers promise such as source, readily linkable to other experimental facilities, or deployable outside a laboratory setting. We present experimental results on the first short-pulse laser-driven neutron source powerful enough for radiography. A novel laser-driven ion acceleration mechanism (Breakout Afterburner), operating in the relativistic transparency regime, is used. Based on the mechanism's advantages, a laser-driven deuteron beam is used to achieve a new record in laser-neutron production, in numbers, energy and directionality. This neutron beam is a highly directional pulse < 1 ns at ˜ 1 cm from the target, with a flux > 40/2̂, and thus suitable for imaging applications with high temporal resolution. The beam contained, for the first time, neutrons with energies of up to 150 MeV. Thus using short pulse lasers, it is now possible to use the resulting hard x-rays and neutrons of different energies to radiograph an unknown object and to determine its material composition. Our data matches the simulated data for our test samples.

  11. Microtron MT 25 as a source of neutrons

    SciTech Connect

    Kralik, M.; Solc, J.; Chvatil, D.; Krist, P.; Turek, K.; Granja, C.

    2012-08-15

    The objective was to describe Microtron MT25 as a source of neutrons generated by bremsstrahlung induced photonuclear reactions in U and Pb targets. Bremsstrahlung photons were produced by electrons accelerated at energy 21.6 MeV. Spectral fluence of the generated neutrons was calculated with MCNPX code and then experimentally determined at two positions by means of a Bonner spheres spectrometer in which the detector of thermal neutrons was replaced by activation Mn tablets or track detectors CR-39 with a {sup 10}B radiator. The measured neutron spectral fluence and the calculated anisotropy served for the estimation of neutron yield from the targets and for the determination of ambient dose equivalent rate at the place of measurement. Microtron MT25 is intended as one of the sources for testing neutron sensitive devices which will be sent into the space.

  12. Microtron MT 25 as a source of neutrons.

    PubMed

    Králík, M; Šolc, J; Chvátil, D; Krist, P; Turek, K; Granja, C

    2012-08-01

    The objective was to describe Microtron MT25 as a source of neutrons generated by bremsstrahlung induced photonuclear reactions in U and Pb targets. Bremsstrahlung photons were produced by electrons accelerated at energy 21.6 MeV. Spectral fluence of the generated neutrons was calculated with MCNPX code and then experimentally determined at two positions by means of a Bonner spheres spectrometer in which the detector of thermal neutrons was replaced by activation Mn tablets or track detectors CR-39 with a (10)B radiator. The measured neutron spectral fluence and the calculated anisotropy served for the estimation of neutron yield from the targets and for the determination of ambient dose equivalent rate at the place of measurement. Microtron MT25 is intended as one of the sources for testing neutron sensitive devices which will be sent into the space. PMID:22938289

  13. Characterization of short-pulse laser driven neutron source

    NASA Astrophysics Data System (ADS)

    Falk, Katerina; Jung, Daniel; Guler, Nevzat; Deppert, Oliver; Devlin, Matthew; Fernandez, J. C.; Gautier, D. C.; Geissel, M.; Haight, R. C.; Hegelich, B. M.; Henzlova, Daniela; Ianakiev, K. D.; Iliev, Metodi; Johnson, R. P.; Merrill, F. E.; Schaumann, G.; Schoenberg, K.; Shimada, T.; Taddeucci, T. N.; Tybo, J. L.; Wagner, F.; Wender, S. A.; Wurden, G. A.; Favalli, Andrea; Roth, Markus

    2014-10-01

    We present a full spectral characterization of a novel laser driven neutron source, which employed the Break Out Afterburner ion acceleration mechanism. Neutrons were produced by nuclear reactions of the ions deposited on Be or Cu converters. We observed neutrons at energies up to 150 MeV. The neutron spectra were measured by five neutron time-of-flight detectors at various positions and distances from the source. The nTOF detectors observed that emission of neutrons is a superposition of an isotropic component peaking at 3.5--5 MeV resulting from nuclear reactions in the converter and a directional component at 25--70 MeV, which was a product of break-up reaction of the forward moving deuterons. Energy shifts due to geometrical effects in BOA were also observed.

  14. A neutron track etch detector for electron linear accelerators in radiotherapy

    PubMed Central

    Vukovic, Branko; Faj, Dario; Poje, Marina; Varga, Maja; Radolic, Vanja; Miklavcic, Igor; Ivkovic, Ana; Planinic, Josip

    2010-01-01

    Background Electron linear accelerators in medical radiotherapy have replaced cobalt and caesium sources of radiation. However, medical accelerators with photon energies over 10 MeV generate undesired fast neutron contamination in a therapeutic X-ray photon beam. Photons with energies above 10 MeV can interact with the atomic nucleus of a high-Z material, of which the target and the head of an accelerator consist, and lead to the neutron ejection. Results and conclusions. Our neutron dosimeter, composed of the LR-115 track etch detector and boron foil BN-1 converter, was calibrated on thermal neutrons generated in the nuclear reactor of the Josef Stefan Institute (Slovenia), and applied to dosimetry of undesirable neutrons in photon radiotherapy by the linear accelerator 15 MV Siemens Mevatron. Having considered a high dependence of a cross-section between neutron and boron on neutron energy, and broad neutron spectrum in a photon beam, as well as outside the entrance door to maze of the Mevatron, we developed a method for determining the effective neutron detector response. A neutron dose rate in the photon beam was measured to be 1.96 Sv/h. Outside the Mevatron room the neutron dose rate was 0.62 μSv/h. PACS: 87.52. Ga; 87.53.St; 29.40.Wk. PMID:22933893

  15. Using spallation neutron sources for defense research

    SciTech Connect

    Pynn, R.; Sterbenz, S.M.; Weinacht, D.J.

    1996-12-31

    Advanced characterization techniques and accelerated simulation are the cornerstones of the Energy Department`s science-based program to maintain confidence in the safety, reliability, and performance of the US nuclear deterrent in an era of no nuclear testing. Neutrons and protons provided by an accelerator-based facility have an important role to play in this program, impacting several of the key stockpile stewardship and management issues identified by the Department of Defense. Many of the techniques used for defense research at a spallation source have been used for many years for the basic research community, and to a lesser extent by industrial scientists. By providing access to a broad spectrum of researchers with different backgrounds, a spallation source such as the Los Alamos Neutron Science Center is able to promote synergistic interaction between defense, basic and industrial researchers. This broadens the scientific basis of the stockpile stewardship program in the short term and will provide spin-off to industrial and basic research in the longer term.

  16. Advanced Neutron Source equipment data base. [Advanced Neutron Source Facility

    SciTech Connect

    Coffin, D.B. )

    1990-08-01

    The Advanced Neutron Source (ANS) is a new experimental facility planned to meet the national need for an intense, steady-state source of neutrons. It will be open for use by scientists from universities, industry, and other federal laboratories. The ANS will be equipped with an initial complement of advanced instruments for neutron scattering and nuclear physics research, with facilities for isotope production and for the study of materials in high radiation fields. The central structure is a 60-m ({approximately}200-ft) diam cylindrical, domed reactor building. This building will house the reactor itself, with its lower floors dedicated to beam and irradiation experiments and with a high-bay floor dedicated to reactor operations. A reactor support building, to be adjacent to the reactor building, will house other large reactor equipment and the general support equipment not located in the reactor building. The primary heat exchanger and circulating pumps will be located in cell banks within reactor containment. The guide hall building, connected to the reactor dome outside reactor containment, is dedicated to beam experiment use. The fourth building will be an office building serving both the extensive user community and the reactor operations staff. These buildings will contain many of the systems needed for operation of the ANS and will be comprised of equipment requiring specification of performance, test, and operating parameters. The number of equipment items, the possibility for multiple application of a particular piece of equipment, and the need for a single source of information for all equipment led to a requirement to develop and equipment-related data base. 3 refs., 2 figs., 1 tab.

  17. Design and demonstration of a quasi-monoenergetic neutron source

    NASA Astrophysics Data System (ADS)

    Joshi, T. H.; Sangiorgio, S.; Mozin, V.; Norman, E. B.; Sorensen, P.; Foxe, M.; Bench, G.; Bernstein, A.

    2014-08-01

    The design of a neutron source capable of producing 24 and 70 keV neutron beams with narrow energy spread is presented. The source exploits near-threshold kinematics of the 7Li (p,n)7Be reaction while taking advantage of the interference ‘notches’ found in the scattering cross-sections of iron. The design was implemented and characterized at the Center for Accelerator Mass Spectrometry at Lawrence Livermore National Laboratory. Alternative filters such as vanadium and manganese are also explored and the possibility of studying the response of different materials to low-energy nuclear recoils using the resultant neutron beams is discussed.

  18. Design and Demonstration of a Quasi-monoenergetic Neutron Source

    SciTech Connect

    Joshi, T.; Sangiorgio, Samuele; Mozin, Vladimir V.; Norman, E. B.; Sorensen, Peter F.; Foxe, Michael P.; Bench, G.; Bernstein, A.

    2014-03-05

    The design of a neutron source capable of producing 24 and 70 keV neutron beams with narrow energy spread is presented. The source exploits near-threshold kinematics of the 7Li(p,n)7Be reaction while taking advantage of the interference `notches' found in the scattering cross-sections of iron. The design was implemented and characterized at the Center for Accelerator Mass Spectrometry at Lawrence Livermore National Laboratory. Alternative lters such as vanadium and manganese are also explored and the possibility of studying the response of di*erent materials to low-energy nuclear recoils using the resultant neutron beams is discussed.

  19. Outline of a proposal for a new neutron source: The pulsed neutron research facility

    SciTech Connect

    Brown, B.S.; Carpenter, J.M.; Kustom, R.L.

    1992-04-01

    Accelerator-based, pulsed spallation neutron sources have been performing neutron scattering research for about fifteen years. During this time beam intensities have increased by a factor of 100 and more than 50 spectrometers are now operating on four major sources worldwide. The pulsed sources have proven to be highly effective and complementary to reactor-based sources in that there are important scientific areas for which each type of source has unique capabilities. We describe a proposal for a new pulsed neutron facility based on a Fixed Field Alternating Gradient synchrotron. The specifications for this new machine, which are now only being formulated, are for an accelerator that will produce (100 {divided_by} 200) {mu}A of time-averaged proton current at (500 {divided_by} 1000) MeV, in short pulses at 30 Hz. Appropriate target and moderator systems and an array of scattering instruments will be provided to make the facility a full-blown research installation. The neutron source, named the Pulsed Neutron Research Facility (PNRF), will be as powerful as any pulsed source now operating in the world and will also act as a test bed for the Fixed Field Alternating Gradient Synchrotron concept as a basis for more powerful sources in the future. The peak thermal neutron flux in PNRF will be about 5{center_dot}10{sup 15}n/cm{sup 2}{center_dot}s.

  20. Outline of a proposal for a new neutron source: The pulsed neutron research facility

    SciTech Connect

    Brown, B.S.; Carpenter, J.M.; Kustom, R.L.

    1992-04-01

    Accelerator-based, pulsed spallation neutron sources have been performing neutron scattering research for about fifteen years. During this time beam intensities have increased by a factor of 100 and more than 50 spectrometers are now operating on four major sources worldwide. The pulsed sources have proven to be highly effective and complementary to reactor-based sources in that there are important scientific areas for which each type of source has unique capabilities. We describe a proposal for a new pulsed neutron facility based on a Fixed Field Alternating Gradient synchrotron. The specifications for this new machine, which are now only being formulated, are for an accelerator that will produce (100 {divided by} 200) {mu}A of time-averaged proton current at (500 {divided by} 1000) MeV, in short pulses at 30 Hz. Appropriate target and moderator systems and an array of scattering instruments will be provided to make the facility a full-blown research installation. The neutron source, named the Pulsed Neutron Research Facility (PNRF), will be as powerful as any pulsed source now operating in the world and will also act as a test bed for the Fixed Field Alternating Gradient Synchrotron concept as a basis for more powerful sources in the future. The peak thermal neutron flux in PNRF will be about 5{center dot}10{sup 15}n/cm{sup 2}{center dot}s.

  1. Muon acceleration in cosmic-ray sources

    SciTech Connect

    Klein, Spencer R.; Mikkelsen, Rune E.; Becker Tjus, Julia

    2013-12-20

    Many models of ultra-high energy cosmic-ray production involve acceleration in linear accelerators located in gamma-ray bursts, magnetars, or other sources. These transient sources have short lifetimes, which necessitate very high accelerating gradients, up to 10{sup 13} keV cm{sup –1}. At gradients above 1.6 keV cm{sup –1}, muons produced by hadronic interactions undergo significant acceleration before they decay. This muon acceleration hardens the neutrino energy spectrum and greatly increases the high-energy neutrino flux. Using the IceCube high-energy diffuse neutrino flux limits, we set two-dimensional limits on the source opacity and matter density, as a function of accelerating gradient. These limits put strong constraints on different models of particle acceleration, particularly those based on plasma wake-field acceleration, and limit models for sources like gamma-ray bursts and magnetars.

  2. A Neutron Source Facility for Neutron Cross-Section Measurements on Radioactive Targets at RIA

    SciTech Connect

    Ahle, L E; Bernstein, L; Rusnak, B; Berio, R

    2003-05-20

    The stockpile stewardship program is interested in neutron cross-section measurements on nuclei that are a few nucleons away from stability. Since neutron targets do not exist, radioactive targets are the only way to directly perform these measurements. This requires a facility that can provide high production rates for these short-lived nuclei as well as a source of neutrons. The Rare Isotope Accelerator (RIA) promises theses high production rates. Thus, adding a co-located neutron source facility to the RIA project baseline would allow these neutron cross-section measurements to be made. A conceptual design for such a neutron source has been developed, which would use two accelerators, a Dynamitron and a linac, to create the neutrons through a variety of reactions (d-d, d-t, deuteron break-up, p-Li). This range of reactions is needed in order to provide the desired energy range from 10's of keV to 20 MeV. The facility would also have hot cells to perform chemistry on the radioactive material both before and after neutron irradiation. The present status of this design and direction of future work will be discussed.

  3. Applying nonlinear diffusion acceleration to the neutron transport k-Eigenvalue problem with anisotropic scattering

    SciTech Connect

    Willert, Jeffrey; Park, H.; Taitano, William

    2015-10-12

    High-order/low-order (or moment-based acceleration) algorithms have been used to significantly accelerate the solution to the neutron transport k-eigenvalue problem over the past several years. Recently, the nonlinear diffusion acceleration algorithm has been extended to solve fixed-source problems with anisotropic scattering sources. In this paper, we demonstrate that we can extend this algorithm to k-eigenvalue problems in which the scattering source is anisotropic and a significant acceleration can be achieved. Lastly, we demonstrate that the low-order, diffusion-like eigenvalue problem can be solved efficiently using a technique known as nonlinear elimination.

  4. The Fundamental Neutron Physics Beamline at the Spallation Neutron Source

    PubMed Central

    Greene, Geoffrey; Cianciolo, Vince; Koehler, Paul; Allen, Richard; Snow, William Michael; Huffman, Paul; Gould, Chris; Bowman, David; Cooper, Martin; Doyle, John

    2005-01-01

    The Spallation Neutron Source (SNS), currently under construction at Oak Ridge National Laboratory with an anticipated start-up in early 2006, will provide the most intense pulsed beams of cold neutrons in the world. At a projected power of 1.4 MW, the time averaged fluxes and fluences of the SNS will approach those of high flux reactors. One of the flight paths on the cold, coupled moderator will be devoted to fundamental neutron physics. The fundamental neutron physics beamline is anticipated to include two beam-lines; a broad band cold beam, and a monochromatic beam of 0.89 nm neutrons for ultracold neutron (UCN) experiments. The fundamental neutron physics beamline will be operated as a user facility with experiment selection based on a peer reviewed proposal process. An initial program of five experiments in neutron decay, hadronic weak interaction and time reversal symmetry violation have been proposed. PMID:27308112

  5. A multitask neutron beam line for spallation neutron sources

    NASA Astrophysics Data System (ADS)

    Pietropaolo, A.; Festa, G.; Grazzi, F.; Barzagli, E.; Scherillo, A.; Schooneveld, E. M.; Civita, F.

    2011-08-01

    Here we present a new concept for a time-of-flight neutron scattering instrument allowing for simultaneous application of three different techniques: time-of-flight neutron diffraction, neutron resonance capture analysis and Bragg edge transmission analysis. The instrument can provide average resolution neutron radiography too. The potential of the proposed concept was explored by implementing the necessary equipment on INES (Italian Neutron Experimental Station) at the ISIS spallation neutron source (UK). The results obtained show the effectiveness of the proposed instrument to acquire relevant quantitative information in a non-invasive way on a historical metallurgical sample, namely a Japanese hand guard (tsuba). The aforementioned neutron techniques simultaneously exploited the extended neutron energy range available from 10 meV to 1 keV. This allowed a fully satisfactory characterization of the sample in terms of metal components and their combination in different phases, and forging and assembling methods.

  6. Gyrotron-driven high current ECR ion source for boron-neutron capture therapy neutron generator

    NASA Astrophysics Data System (ADS)

    Skalyga, V.; Izotov, I.; Golubev, S.; Razin, S.; Sidorov, A.; Maslennikova, A.; Volovecky, A.; Kalvas, T.; Koivisto, H.; Tarvainen, O.

    2014-12-01

    Boron-neutron capture therapy (BNCT) is a perspective treatment method for radiation resistant tumors. Unfortunately its development is strongly held back by a several physical and medical problems. Neutron sources for BNCT currently are limited to nuclear reactors and accelerators. For wide spread of BNCT investigations more compact and cheap neutron source would be much more preferable. In present paper an approach for compact D-D neutron generator creation based on a high current ECR ion source is suggested. Results on dense proton beams production are presented. A possibility of ion beams formation with current density up to 600 mA/cm2 is demonstrated. Estimations based on obtained experimental results show that neutron target bombarded by such deuteron beams would theoretically yield a neutron flux density up to 6·1010 cm-2/s. Thus, neutron generator based on a high-current deuteron ECR source with a powerful plasma heating by gyrotron radiation could fulfill the BNCT requirements significantly lower price, smaller size and ease of operation in comparison with existing reactors and accelerators.

  7. Ion sources for sealed neutron tubes

    SciTech Connect

    Burns, E.J.T.; Bischoff, G.C.

    1996-11-01

    Fast and thermal neutron activation analysis with sealed neutron generators has been used to detect oil (oil logging), hazardous waste, fissile material, explosives, and contraband (drugs). Sealed neutron generators, used in the above applications, must be small and portable, have good electrical efficiency and long life. The ion sources used in the sealed neutron tubes require high gas utilization efficiencies or low pressure operation with high ionization efficiencies. In this paper, the authors compare a number of gas ion sources that can be used in sealed neutron tubes. The characteristics of the most popular ion source, the axial Penning discharge will be discussed as part of the zetatron neutron generator. Other sources to be discussed include the SAMIS source and RF ion source.

  8. SELF-REACTIVATING NEUTRON SOURCE FOR A NEUTRONIC REACTOR

    DOEpatents

    Newson, H.W.

    1959-02-01

    Reactors of the type employing beryllium in a reflector region around the active portion and to a neutron source for use therewith are discussed. The neutron source is comprised or a quantity of antimony permanently incorporated in, and as an integral part of, the reactor in or near the beryllium reflector region. During operation of the reactor the natural occurring antimony isotope of atomic weight 123 absorbs neutrons and is thereby transformed to the antimony isotope of atomic weight 124, which is radioactive and emits gamma rays. The gamma rays react with the beryllium to produce neutrons. The beryllium and antimony thus cooperate to produce a built in neutron source which is automatically reactivated by the operation of the reactor itself and which is of sufficient strength to maintain the slow neutron flux at a sufficiently high level to be reliably measured during periods when the reactor is shut down.

  9. Ultra-bright laser-driven neutron source

    NASA Astrophysics Data System (ADS)

    Roth, M.; Favalli, A.; Bagnoud, V.; Bridgewater, J.; Deppert, O.; Devlin, M.; Falk, K.; Fernndez, J.; Gautier, D.; Guler, N.; Henzlova, D.; Hornung, J.; Iliev, M.; Ianakiev, K.; Kleinschmidt, A.; Koehler, K.; Palaniyappan, S.; Poth, P.; Schaumann, G.; Swinhoe, M.; Taddeucci, T.; Tebartz, A.; Wagner, Florian; Wurden, G.

    2015-11-01

    Short-pulse laser-driven neutron sources have become a topic of interest since their brightness and yield have recently increased by orders of magnitude. Using novel target designs, high contrast - high power lasers and compact converter/moderator setups, these neutron sources have finally reached intensities that make many interesting applications possible. We present the results of two experimental campaigns on the GSI PHELIX and the LANL Trident lasers from 2015. We have produced an unprecedented neutron flux, mapped the spatial distribution of the neutron production as well as its energy spectra and ultimately used the beam for first applications to show the prospect of these new compact sources. We also made measurements for the conversion of energetic neutrons into short epithermal and thermal neutron pulses in order to evaluate further applications in dense plasma research. The results address a large community as it paves the way to use short pulse lasers as a neutron source. This can open up neutron research to a broad academic community including material science, biology, medicine and high energy density physics to universities and therefore can complement large scale facilities like reactors or particle accelerators.

  10. Epithermal Neutron Source for Neutron Resonance Spectroscopy (NRS) using High Intensity, Short Pulse Lasers

    SciTech Connect

    Higginson, D P; McNaney, J M; Swift, D C; Bartal, T; Hey, D S; Pape, S L; Mackinnon, A; Mariscal, D; Nakamura, H; Nakanii, N; Beg, F N

    2010-04-22

    A neutron source for neutron resonance spectroscopy (NRS) has been developed using high intensity, short pulse lasers. This measurement technique will allow for robust measurements of interior ion temperature of laser-shocked materials and provide insight into equation of state (EOS) measurements. The neutron generation technique uses protons accelerated by lasers off of Cu foils to create neutrons in LiF, through (p,n) reactions with {sup 7}Li and {sup 19}F. The distribution of the incident proton beam has been diagnosed using radiochromic film (RCF). This distribution is used as the input for a (p,n) neturon prediction code which is compared to experimentally measured neutron yields. From this calculation, a total fluence of 1.8 x 10{sup 9} neutrons is infered, which is shown to be a reasonable amount for NRS temperature measurement.

  11. Switchable radioactive neutron source device

    DOEpatents

    Stanford, G.S.; Rhodes, E.A.; Devolpi, A.; Boyar, R.E.

    1987-11-06

    This invention is a switchable neutron generating apparatus comprised of a pair of plates, the first plate having an alpha emitter section on it and the second plate having a target material portion on it which generates neutrons when its nuclei absorb an alpha particle. In operation, the alpha portion of the first plate is aligned with the neutron portion of the second plate to produce neutrons and brought out of alignment to cease production of neutrons. 3 figs.

  12. Switchable radioactive neutron source device

    DOEpatents

    Boyar, Robert E.; DeVolpi, Alexander; Stanford, George S.; Rhodes, Edgar A.

    1989-01-01

    This invention is a switchable neutron generating apparatus comprised of a pair of plates, the first plate having an alpha emitter section on it and the second plate having a target material portion on it which generates neutrons when its nuclei absorb an alpha particle. In operation, the alpha portion of the first plate is aligned with the neutron portion of the second plate to produce neutrons and brought out of alignment to cease production of neutrons.

  13. A measurement of actinide neutron transmutations with accelerator mass spectrometry in order to infer neutron capture cross sections

    NASA Astrophysics Data System (ADS)

    Bauder, William K.

    Improved neutron capture cross section data for transuranic and minor actinides are essential for assessing possibilities for next generation reactors and advanced fuel cycles. The Measurement of Actinide Neutron TRAnsmutation (MANTRA) project aims to make a comprehensive set of energy integrated neutron capture cross section measurements for all relevant isotopes from Th to Cf. The ability to extract these cross sections relies on the use of Accelerator Mass Spectrometry (AMS) to analyze isotopic concentrations in samples irradiated in the Advanced Test Reactor (ATR). The AMS measurements were performed at the Argonne Tandem Linear Accelerator System (ATLAS) and required a number of key technical developments to the ion source, accelerator, and detector setup. In particular, a laser ablation material injection system was developed at the electron cyclotron resonance ion source. This system provides a more effective method to produce ion beams from samples containing only 1% actinide material and offers some benefits for reducing cross talk in the source. A series of four actinide measurements are described in this dissertation. These measurements represent the most substantial AMS work attempted at ATLAS and the first results of the MANTRA project. Isotopic ratios for one and two neutron captures were measured in each sample with total uncertainties around 10%. These results can be combined with a MCNP model for the neutron fluence to infer actinide neutron capture cross sections.

  14. Slow neutron leakage spectra from spallation neutron sources

    SciTech Connect

    Das, S.G.; Carpenter, J.M.; Prael, R.E.

    1980-02-01

    An efficient technique is described for Monte Carlo simulation of neutron beam spectra from target-moderator-reflector assemblies typical of pulsed spallation neutron sources. The technique involves the scoring of the transport-theoretical probability that a neutron will emerge from the moderator surface in the direction of interest, at each collision. An angle-biasing probability is also introduced which further enhances efficiency in simple problems. These modifications were introduced into the VIM low energy neutron transport code, representing the spatial and energy distributions of the source neutrons approximately as those of evaporation neutrons generated through the spallation process by protons of various energies. The intensity of slow neutrons leaking from various reflected moderators was studied for various neutron source arrangements. These include computations relating to early measurements on a mockup-assembly, a brief survey of moderator materials and sizes, and a survey of the effects of varying source and moderator configurations with a practical, liquid metal cooled uranium source Wing and slab, i.e., tangential and radial moderator arrangements, and Be vs CH/sub 2/ reflectors are compared. Results are also presented for several complicated geometries which more closely represent realistic arrangements for a practical source, and for a subcritical fission multiplier such as might be driven by an electron linac. An adaptation of the code was developed to enable time dependent calculations, and investigated the effects of the reflector, decoupling and void liner materials on the pulse shape.

  15. European Spallation Source and Neutron Science

    NASA Astrophysics Data System (ADS)

    Yeck, James

    2014-03-01

    International collaborations in large-scale scientific projects can link Sciences and Society. Following this goal, the European Spallation Source (ESS) is a multi-disciplinary research centre under design and construction in Lund, Sweden. This new facility is funded by a collaboration of 17 European countries. Scandinavia is providing 50 percent of the construction cost whilst the other member states are providing financial support mainly via in-kind contribution from institutes, laboratories or industries of the given countries. Scientists and engineers from 35 different countries are members of the workforce in Lund who participate in its design and construction. The ESS will enable new opportunities for researchers in fields of life sciences, energy, environmental technology, cultural heritage and fundamental physics by producing very high flux neutrons to study condensed matter physics, chemistry, biology, nuclear physics and materials science. The ESS will be up to 30 times brighter than today's leading facilities and neutron sources. A tungsten target and a 5 MW long pulse proton accelerator, composed mainly of superconducting Radio-Frequency components, are used to achieve these goals.

  16. Status of the intense pulsed neutron source

    SciTech Connect

    Carpenter, J.M.; Brown, B.S.; Kustom, R.L.; Lander, G.H.; Potts, C.W.; Schulke, A.W.; Wuestefeld, G.

    1985-01-01

    Fortunately in spite of some premature reports of its impending demise, IPNS has passed the fourth anniversary of the first delivery of protons to the targets (May 5, 1981) and is approaching the fourth anniversary of its operation as a scattering facility (August 4, 1981). On June 10, 1984, the RCS delivered its one billionth pulse to the IPNS target - the total number of protons delivered to the targets amounted then to 75 stp cm/sup 3/ of H/sub 2/ gas. Since startup IPNS has improved steadily in terms of the performance of the Rapid Cycling Synchrotron, the source and its moderators and the scattering instruments, and a substantial and productive user program has evolved. This report summarizes the current status of the Intense Pulsed Neutron Source at Argonne National Laboratory. We include reference to recent accelerator operating experience, neutron facility operating experience, improvements to these systems, design work on the ASPUN high-current facility, booster target design, the new solid methane moderator, characterization of the room temperature moderators, and provide some examples of recent results from several of the spectrometers.

  17. An Ultra-Short Pulsed Neutron Source

    NASA Astrophysics Data System (ADS)

    Pomerantz, Ishay; McCary, Eddie; Meadows, Alexander R.; Arefiev, Alexey; Bernstein, Aaron C.; Chester, Clay; Cortez, Jose; Donovan, Michael E.; Dyer, Gilliss; Gaul, Erhard W.; Hamilton, David; Kuk, Donghoon; Lestrade, Arantxa; Wang, Chunhua; Ditmire, Todd; Hegelich, Manuel B.

    2014-10-01

    We report on a novel compact laser-driven neutron source with unprecedented short pulse duration (<50 ps) and high flux (>1018 neutrons/cm2/s), an order of magnitude higher than any existing source. In our experiments, high-energy electron jets are generated from thin (<1 μm) plastic targets irradiated by a petawatt laser. These intense electron beams are employed to generate neutrons from a metal converter. Our method opens venues for enhancing neutron radiography contrast, conducting time-resolved neutron-damage studies at their characteristic evolution time-scales and for creating astrophysical conditions of heavy element synthesis in the laboratory.

  18. Compact, energy EFFICIENT neutron source: enabling technology for various applications

    SciTech Connect

    Hershcovitch, A.; Roser, T.

    2009-12-01

    A novel neutron source comprising of a deuterium beam (energy of about 100 KeV) injected into a tube filled with tritium gas and/or tritium plasma that generates D-T fusion reactions, whose products are 14.06 MeV neutrons and 3.52 MeV alpha particles, is described. At the opposite end of the tube, the energy of deuterium ions that did not interact is recovered. Beryllium walls of proper thickness can be utilized to absorb 14 MeV neutrons and release 2-3 low energy neutrons. Each ion source and tube forms a module. Larger systems can be formed from multiple units. Unlike currently proposed methods, where accelerator-based neutron sources are very expensive, large, and require large amounts of power for operation, this neutron source is compact, inexpensive, easy to test and to scale up. Among possible applications for this neutron source concept are sub-critical nuclear breeder reactors and transmutation of radioactive waste.

  19. Study of Direct Current Negative Ion Source for Medicine Accelerator

    SciTech Connect

    Belchenko, Yu.; Ivanov, I.; Piunov, I.

    2005-04-06

    Status of dc H- ion source development for tandem accelerator of boron capture neutron therapy is described. Upgrade and study of the Penning surface-plasma source with hollow cathodes was continued. Results of source optimization, of ion optic computer simulation, and of emittance measurement are presented. The upgraded source delivers dc H- beam with energy 25 kV, current 8 mA, 1rms emittance JukcyX {approx} 0.2 {pi} mm{center_dot}mrad, JukcyY {approx} 0.3 {pi} mm{center_dot}mrad at discharge power {<=} 0.5 kW.

  20. Materials and neutronic research at the Low Energy Neutron Source

    NASA Astrophysics Data System (ADS)

    Baxter, David V.

    2016-04-01

    In the decade since the Low Energy Neutron Source (LENS) at Indiana University Center for Exploration of Energy and Matter (CEEM) produced its first neutrons, the facility has made important contributions to the international neutron scattering community. LENS employs a 13MeV proton beam at up to 4kW beam power onto one of two Be targets to produce neutrons for research in fields ranging from radiation effects in electronics to studies of the structure of fluids confined in nanoporous materials. The neutron source design at the heart of LENS facilitates relatively rapid hands-on access to most of its components which provides a foundation for a research program in experimental neutronics and affords numerous opportunities for novel educational experiences. We describe in some detail a number of the unique capabilities of this facility.

  1. Neutron Sources for Standard-Based Testing

    SciTech Connect

    Radev, Radoslav; McLean, Thomas

    2014-11-10

    The DHS TC Standards and the consensus ANSI Standards use 252Cf as the neutron source for performance testing because its energy spectrum is similar to the 235U and 239Pu fission sources used in nuclear weapons. An emission rate of 20,000 ± 20% neutrons per second is used for testing of the radiological requirements both in the ANSI standards and the TCS. Determination of the accurate neutron emission rate of the test source is important for maintaining consistency and agreement between testing results obtained at different testing facilities. Several characteristics in the manufacture and the decay of the source need to be understood and accounted for in order to make an accurate measurement of the performance of the neutron detection instrument. Additionally, neutron response characteristics of the particular instrument need to be known and taken into account as well as neutron scattering in the testing environment.

  2. Dosimetry and fast neutron energies characterization of photoneutrons produced in some medical linear accelerators

    NASA Astrophysics Data System (ADS)

    Khaled, N. E.; Attalla, E. M.; Ammar, H.; Khalil, W.

    2011-12-01

    This work focusses on the estimation of induced photoneutrons energy, fluence, and strength using nuclear track detector (NTD) (CR-39). Photoneutron energy was estimated for three different linear accelerators, LINACs as an example for the commonly used accelerators. For high-energy linear accelerators, neutrons are produced as a consequence of photonuclear reactions in the target nuclei, accelerator head, field-flattening filters and beam collimators, and other irradiated objects. NTD (CR-39) is used to evaluate energy and fluence of the fast neutron. Track length is used to estimate fast photoneutrons energy for linear accelerators (Elekta 10 MV, Elekta 15 MV, and Varian 15 MV). Results show that the estimated neutron energies for the three chosen examples of LINACs reveals neutron energies in the range of 1-2 MeV for 10 and 15 MV X-ray beams. The fluence of neutrons at the isocenter (Φtotal) is found to be (4×106 n cm2 Gy-1) for Elekta machine 10 MV. The neutron source strengths Q are calculated. It was found to be 0.2×1012 n Gy-1 X-ray at the isocenter. This work represents simple, low cost, and accurate methods of measuring fast neutrons dose and energies.

  3. Spallation Neutron Source reaches megawatt power

    ScienceCinema

    Dr. William F. Brinkman

    2010-01-08

    The Department of Energy's Spallation Neutron Source (SNS), already the world's most powerful facility for pulsed neutron scattering science, is now the first pulsed spallation neutron source to break the one-megawatt barrier. "Advances in the materials sciences are fundamental to the development of clean and sustainable energy technologies. In reaching this milestone of operating power, the Spallation Neutron Source is providing scientists with an unmatched resource for unlocking the secrets of materials at the molecular level," said Dr. William F. Brinkman, Director of DOE's Office of Science.

  4. Spallation Neutron Source reaches megawatt power

    SciTech Connect

    Dr. William F. Brinkman

    2009-09-30

    The Department of Energy's Spallation Neutron Source (SNS), already the world's most powerful facility for pulsed neutron scattering science, is now the first pulsed spallation neutron source to break the one-megawatt barrier. "Advances in the materials sciences are fundamental to the development of clean and sustainable energy technologies. In reaching this milestone of operating power, the Spallation Neutron Source is providing scientists with an unmatched resource for unlocking the secrets of materials at the molecular level," said Dr. William F. Brinkman, Director of DOE's Office of Science.

  5. Neutron producing reactions in PuBe neutron sources

    NASA Astrophysics Data System (ADS)

    Bagi, János; Lakosi, László; Nguyen, Cong Tam

    2016-01-01

    There are a plenty of out-of-use plutonium-beryllium neutron sources in Eastern Europe presenting both nuclear safeguards and security issues. Typically, their actual Pu content is not known. In the last couple of years different non-destructive methods were developed for their characterization. For such methods detailed knowledge of the nuclear reactions taking place within the source is necessary. In this paper we investigate the role of the neutron producing reactions, their contribution to the neutron yield and their dependence on the properties of the source.

  6. Neutron sources for a neutron capture therapy facility

    SciTech Connect

    Lennox, A.J.

    1993-04-01

    Recent advances in the development of boron pharmaceuticals have reopened the possibility of using epithermal neutrons to treat brain tumors containing boron-10. This paper summarizes the approaches being used to generate the neutron sources and identifies specific areas where more research and development are needed.

  7. Neutron fan beam source for neutron radiography purpose

    SciTech Connect

    Le Tourneur, P.; Bach, P.; Dance, W. E.

    1999-06-10

    The development of the DIANE neutron radiography system included a sealed-tube neutron generator for this purpose and the optimization of the system's neutron beam quality in terms of divergence and useful thermal neutron yield for each 14-MeV neutron produced. Following this development, the concept of a DIANE fan beam source is herewith introduced. The goal which drives this design is one of economy: by simply increasing the aperture dimension of a conventional DIANE beam in one plane of its collimator axis to a small-angle, fan-shaped output, the useful beam area for neutron radiography would be substantially increased. Thus with the same source, the throughput, or number of objects under examination at any given time, would be augmented significantly. Presented here are the design of this thermal neutron source and the initial Monte Carlo calculations. Taking into account the experience with the conventional DIANE neutron radiography system, these result are discussed and the potential of and interest in such a fan-beam source are explored.

  8. Nested Focusing Optics for Compact Neutron Sources

    NASA Technical Reports Server (NTRS)

    Nabors, Sammy A.

    2015-01-01

    NASA's Marshall Space Flight Center, the Massachusetts Institute of Technology (MIT), and the University of Alabama Huntsville (UAH) have developed novel neutron grazing incidence optics for use with small-scale portable neutron generators. The technology was developed to enable the use of commercially available neutron generators for applications requiring high flux densities, including high performance imaging and analysis. Nested grazing incidence mirror optics, with high collection efficiency, are used to produce divergent, parallel, or convergent neutron beams. Ray tracing simulations of the system (with source-object separation of 10m for 5 meV neutrons) show nearly an order of magnitude neutron flux increase on a 1-mm diameter object. The technology is a result of joint development efforts between NASA and MIT researchers seeking to maximize neutron flux from diffuse sources for imaging and testing applications.

  9. BEAM LOSS MITIGATION IN THE OAK RIDGE SPALLATION NEUTRON SOURCE

    SciTech Connect

    Plum, Michael A

    2012-01-01

    The Oak Ridge Spallation Neutron Source (SNS) accelerator complex routinely delivers 1 MW of beam power to the spallation target. Due to this high beam power, understanding and minimizing the beam loss is an ongoing focus area of the accelerator physics program. In some areas of the accelerator facility the equipment parameters corresponding to the minimum loss are very different from the design parameters. In this presentation we will summarize the SNS beam loss measurements, the methods used to minimize the beam loss, and compare the design vs. the loss-minimized equipment parameters.

  10. rf improvements for Spallation Neutron Source H-ion source

    SciTech Connect

    Kang, Yoon W; Fuja, Raymond E; Goulding, Richard Howell; Hardek, Thomas W; Lee, Sung-Woo; McCarthy, Mike; Piller, Chip; Shin, Ki; Stockli, Martin P; Welton, Robert F

    2010-01-01

    The Spallation Neutron Source at Oak Ridge National Laboratory is ramping up the accelerated proton beam power to 1.4 MW and just reached 1 MW. The rf-driven multicusp ion source that originates from the Lawrence Berkeley National Laboratory has been delivering 38 mA H beam in the linac at 60 Hz, 0.9 ms. To improve availability, a rf-driven external antenna multicusp ion source with a water-cooled ceramic aluminum nitride AlN plasma chamber is developed. Computer modeling and simulations have been made to analyze and optimize the rf performance of the new ion source. Operational statistics and test runs with up to 56 mA medium energy beam transport beam current identify the 2 MHz rf system as a limiting factor in the system availability and beam production. Plasma ignition system is under development by using a separate 13 MHz system. To improve the availability of the rf power system with easier maintenance, we tested a 70 kV isolation transformer for the 80 kW, 6% duty cycle 2 MHz amplifier to power the ion source from a grounded solid-state amplifier. 2010 American Institute of Physics.

  11. rf improvements for Spallation Neutron Source H- ion source.

    PubMed

    Kang, Y W; Fuja, R; Goulding, R H; Hardek, T; Lee, S-W; McCarthy, M P; Piller, M C; Shin, K; Stockli, M P; Welton, R F

    2010-02-01

    The Spallation Neutron Source at Oak Ridge National Laboratory is ramping up the accelerated proton beam power to 1.4 MW and just reached 1 MW. The rf-driven multicusp ion source that originates from the Lawrence Berkeley National Laboratory has been delivering approximately 38 mA H(-) beam in the linac at 60 Hz, 0.9 ms. To improve availability, a rf-driven external antenna multicusp ion source with a water-cooled ceramic aluminum nitride (AlN) plasma chamber is developed. Computer modeling and simulations have been made to analyze and optimize the rf performance of the new ion source. Operational statistics and test runs with up to 56 mA medium energy beam transport beam current identify the 2 MHz rf system as a limiting factor in the system availability and beam production. Plasma ignition system is under development by using a separate 13 MHz system. To improve the availability of the rf power system with easier maintenance, we tested a 70 kV isolation transformer for the 80 kW, 6% duty cycle 2 MHz amplifier to power the ion source from a grounded solid-state amplifier. PMID:20192394

  12. Basic physics with spallation-neutron sources

    SciTech Connect

    Michaudon, A.F.

    1994-05-01

    The neutron has unique intrinsic properties widely used in basic and applied sciences. The neutron plays a well-known role in applied sciences and technology and is a unique probe well suited for the exploration of condensed-matter properties. But the neutron is also used for many other basic-physics studies, including nuclear physics, particle physics, fundamental physics, astrophysics, and cosmology. These last studies are briefly reviewed in this paper. Spallation-neutron sources today have unmatched neutron-beam properties for such studies and have great potential in future technological developments whereby these studies could be carried out under much improved conditions.

  13. Study of accelerator neutrino detection at a spallation source

    NASA Astrophysics Data System (ADS)

    Huang, Ming-Yang

    2016-06-01

    We study the detection of accelerator neutrinos produced at the China Spallation Neutron Source (CSNS). Using the code FLUKA, we have simulated the production of neutrinos in a proton beam on a tungsten target and obtained the yield efficiency, numerical flux, and average energy of different flavors of neutrinos. Furthermore, detection of these accelerator neutrinos is investigated in two reaction channels: neutrino-electron reactions and neutrino-carbon reactions. The expected numbers of different flavors of neutrinos have also been calculated. Supported by National Natural Science Foundation of China (11205185, 11175020)

  14. International workshop on cold neutron sources

    SciTech Connect

    Russell, G.J.; West, C.D. )

    1991-08-01

    The first meeting devoted to cold neutron sources was held at the Los Alamos National Laboratory on March 5--8, 1990. Cosponsored by Los Alamos and Oak Ridge National Laboratories, the meeting was organized as an International Workshop on Cold Neutron Sources and brought together experts in the field of cold-neutron-source design for reactors and spallation sources. Eighty-four people from seven countries attended. Because the meeting was the first of its kind in over forty years, much time was spent acquainting participants with past and planned activities at reactor and spallation facilities worldwide. As a result, the meeting had more of a conference flavor than one of a workshop. The general topics covered at the workshop included: Criteria for cold source design; neutronic predictions and performance; energy deposition and removal; engineering design, fabrication, and operation; material properties; radiation damage; instrumentation; safety; existing cold sources; and future cold sources.

  15. Neutron scattering instrumentation for biology at spallation neutron sources

    SciTech Connect

    Pynn, R.

    1994-12-31

    Conventional wisdom holds that since biological entities are large, they must be studied with cold neutrons, a domain in which reactor sources of neutrons are often supposed to be pre-eminent. In fact, the current generation of pulsed spallation neutron sources, such as LANSCE at Los Alamos and ISIS in the United Kingdom, has demonstrated a capability for small angle scattering (SANS) - a typical cold- neutron application - that was not anticipated five years ago. Although no one has yet built a Laue diffractometer at a pulsed spallation source, calculations show that such an instrument would provide an exceptional capability for protein crystallography at one of the existing high-power spoliation sources. Even more exciting is the prospect of installing such spectrometers either at a next-generation, short-pulse spallation source or at a long-pulse spallation source. A recent Los Alamos study has shown that a one-megawatt, short-pulse source, which is an order of magnitude more powerful than LANSCE, could be built with today`s technology. In Europe, a preconceptual design study for a five-megawatt source is under way. Although such short-pulse sources are likely to be the wave of the future, they may not be necessary for some applications - such as Laue diffraction - which can be performed very well at a long-pulse spoliation source. Recently, it has been argued by Mezei that a facility that combines a short-pulse spallation source similar to LANSCE, with a one-megawatt, long-pulse spallation source would provide a cost-effective solution to the global shortage of neutrons for research. The basis for this assertion as well as the performance of some existing neutron spectrometers at short-pulse sources will be examined in this presentation.

  16. Leakage neutron radiation in a medical electron accelerator

    NASA Astrophysics Data System (ADS)

    Paredes, Lydia; Balcazar, Miguel; Genis, Roberto; Ortiz, Raúl

    2001-10-01

    A simple method was used for the calculation of neutron yield produced by main components of medical electron accelerator head, using a simplified geometric model with spherical-shell for the head shielding made of different materials. The leakage neutron radiation on the patient plane and outside the patient plane at one meter from the x-ray target for a Varian accelerator model Clinac 2100C was evaluated experimentally, using Panasonic UD-802 and UD-809 thermoluminescent dosimeters and CR-39 nuclear track dosimeters. The measured values of leakage neutron radiation were lower than the limits specified in the NCRP-102 and IEC 60601-2-1-Ed.2.0 reports.

  17. Improved Actinide Neutron Capture Cross Sections Using Accelerator Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Bauder, W.; Pardo, R. C.; Kondev, F. G.; Kondrashev, S.; Nair, C.; Nusair, O.; Palchan, T.; Scott, R.; Seweryniak, D.; Vondrasek, R.; Collon, P.; Paul, M.; Youinou, G.; Salvatores, M.; Palmotti, G.; Berg, J.; Maddock, T.; Imel, G.

    2014-09-01

    The MANTRA (Measurement of Actinide Neutron TRAnsmutations) project will improve energy-integrated neutron capture cross section data across the actinide region. These data are incorporated into nuclear reactor models and are an important piece in understanding Generation IV reactor designs. We will infer the capture cross sections by measuring isotopic ratios from actinide samples, irradiated in the Advanced Test Reactor at INL, with Accelerator Mass Spectrometry (AMS) at ATLAS (ANL). The superior sensitivity of AMS allows us to extract multiple cross sections from a single sample. In order to analyze the large number of samples needed for MANTRA and to meet the goal of extracting multiple cross sections per sample, we have made a number of modifications to the AMS setup at ATLAS. In particular, we are developing a technique to inject solid material into the ECR with laser ablation. With laser ablation, we can better control material injection and potentially increase efficiency in the ECR, thus creating less contamination in the source and reducing cross talk. I will present work on the laser ablation system and preliminary results from our AMS measurements. The MANTRA (Measurement of Actinide Neutron TRAnsmutations) project will improve energy-integrated neutron capture cross section data across the actinide region. These data are incorporated into nuclear reactor models and are an important piece in understanding Generation IV reactor designs. We will infer the capture cross sections by measuring isotopic ratios from actinide samples, irradiated in the Advanced Test Reactor at INL, with Accelerator Mass Spectrometry (AMS) at ATLAS (ANL). The superior sensitivity of AMS allows us to extract multiple cross sections from a single sample. In order to analyze the large number of samples needed for MANTRA and to meet the goal of extracting multiple cross sections per sample, we have made a number of modifications to the AMS setup at ATLAS. In particular, we are

  18. Modulating the Neutron Flux from a Mirror Neutron Source

    SciTech Connect

    Ryutov, D D

    2011-09-01

    A 14-MeV neutron source based on a Gas-Dynamic Trap will provide a high flux of 14 MeV neutrons for fusion materials and sub-component testing. In addition to its main goal, the source has potential applications in condensed matter physics and biophysics. In this report, the author considers adding one more capability to the GDT-based neutron source, the modulation of the neutron flux with a desired frequency. The modulation may be an enabling tool for the assessment of the role of non-steady-state effects in fusion devices as well as for high-precision, low-signal basic science experiments favoring the use of the synchronous detection technique. A conclusion is drawn that modulation frequency of up to 1 kHz and modulation amplitude of a few percent is achievable. Limitations on the amplitude of modulations at higher frequencies are discussed.

  19. Advanced Neutron Source (ANS) Project progress report

    SciTech Connect

    McBee, M.R.; Chance, C.M. ); Selby, D.L.; Harrington, R.M.; Peretz, F.J. )

    1990-04-01

    This report discusses the following topics on the advanced neutron source: quality assurance (QA) program; reactor core development; fuel element specification; corrosion loop tests and analyses; thermal-hydraulic loop tests; reactor control concepts; critical and subcritical experiments; material data, structural tests, and analysis; cold source development; beam tube, guide, and instrument development; hot source development; neutron transport and shielding; I C research and development; facility concepts; design; and safety.

  20. Fission-neutrons source with fast neutron-emission timing

    NASA Astrophysics Data System (ADS)

    Rusev, G.; Baramsai, B.; Bond, E. M.; Jandel, M.

    2016-05-01

    A neutron source with fast timing has been built to help with detector-response measurements. The source is based on the neutron emission from the spontaneous fission of 252Cf. The time is provided by registering the fission fragments in a layer of a thin scintillation film with a signal rise time of 1 ns. The scintillation light output is measured by two silicon photomultipliers with rise time of 0.5 ns. Overall time resolution of the source is 0.3 ns. Design of the source and test measurements using it are described. An example application of the source for determining the neutron/gamma pulse-shape discrimination by a stilbene crystal is given.

  1. Characteristics comparison between a cyclotron-based neutron source and KUR-HWNIF for boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Tanaka, H.; Sakurai, Y.; Suzuki, M.; Masunaga, S.; Kinashi, Y.; Kashino, G.; Liu, Y.; Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Maruhashi, A.; Ono, K.

    2009-06-01

    At Kyoto University Research Reactor Institute (KURRI), 275 clinical trials of boron neutron capture therapy (BNCT) have been performed as of March 2006, and the effectiveness of BNCT has been revealed. In order to further develop BNCT, it is desirable to supply accelerator-based epithermal-neutron sources that can be installed near the hospital. We proposed the method of filtering and moderating fast neutrons, which are emitted from the reaction between a beryllium target and 30-MeV protons accelerated by a cyclotron accelerator, using an optimum moderator system composed of iron, lead, aluminum and calcium fluoride. At present, an epithermal-neutron source is under construction from June 2008. This system consists of a cyclotron accelerator, beam transport system, neutron-yielding target, filter, moderator and irradiation bed. In this article, an overview of this system and the properties of the treatment neutron beam optimized by the MCNPX Monte Carlo neutron transport code are presented. The distribution of biological effect weighted dose in a head phantom compared with that of Kyoto University Research Reactor (KUR) is shown. It is confirmed that for the accelerator, the biological effect weighted dose for a deeply situated tumor in the phantom is 18% larger than that for KUR, when the limit dose of the normal brain is 10 Gy-eq. The therapeutic time of the cyclotron-based neutron sources are nearly one-quarter of that of KUR. The cyclotron-based epithermal-neutron source is a promising alternative to reactor-based neutron sources for treatments by BNCT.

  2. The University of Texas Cold Neutron Source

    NASA Astrophysics Data System (ADS)

    Ünlü, Kenan; Ríos-Martínez, Carlos; Wehring, Bernard W.

    1994-12-01

    A cold neutron source has been designed, constructed, and tested by the Nuclear Engineering Teaching Laboratory (NETL) at The University of Texas at Austin. The Texas Cold Neutron Source (TCNS) is located in one of the beam ports of the NETL 1-MW TRIGA Mark II research reactor. The main components of the TCNS are a cooled moderator, a heat pipe, a cryogenic refrigerator, and a neutron guide. 80 ml of mesitylene moderator are maintained at about 30 K in a chamber within the reactor graphite reflector by the heat pipe and cryogenic refrigerator. The heat pipe is a 3-m long aluminum tube that contains neon as the working fluid. The cold neutrons obtained from the moderator are transported by a curved 6-m long neutron guide. This neutron guide has a radius of curvature of 300 m, a 50 × 15 mm cross-section, 58Ni coating, and is separated into three channels. The TCNS will provide a low-background subthermal neutron beam for neutron capture and scattering research. After the installation of the external portion of the neutron guide, a neutron focusing system and a Prompt Gamma Activation Analysis facility will be set up at the TCNS.

  3. High-current negative-ion sources for pulsed spallation neutron sources: LBNL workshop, October 1994

    SciTech Connect

    Alonso, J.R.

    1995-09-01

    The neutron scattering community has endorsed the need for a high-power (1 to 5 MW) accelerator-driven source of neutrons for materials research. Properly configured, the accelerator could produce very short (sub-microsecond) bursts of cold neutrons, said time structure offering advantages over the continuous flux from a reactor. The recent cancellation of the ANS reactor project has increased the urgency to develop a comprehensive strategy based on the best technological scenarios. Studies to date have built on the experience from ISIS (the 160 kW source in the UK), and call for a high-current (approx. 100 mA peak) H- source-linac combination injecting into one or more accumulator rings in which beam may be further accelerated. The I to 5 GeV proton beam is extracted in a single turn and brought to the target-moderator stations. The high current, high duty-factor, high brightness and high reliability required of the ion source present a very large challenge to the ion source community. The Workshop reported on here, held in Berkeley in October 1994, analyzed in detail the source requirements for proposed accelerator scenarios, the present performance capabilities of different H- source technologies, and identified necessary R&D efforts to bridge the gap.

  4. Laser ion sources for particle accelerators

    NASA Astrophysics Data System (ADS)

    Sherwood, T. R.

    1996-05-01

    There is an interest in accelerating atomic nuclei to produce particle beams for medical therapy, atomic and nuclear physics, inertial confinement fusion and particle physics. Laser Ion Sources, in which ions are extracted from plasma created when a high power density laser beam pulse strikes a solid surface in a vacuum, are not in common use. However, some new developments in which heavy ions have been accelerated show that such sources have the potential to provide the beams required for high-energy accelerator systems.

  5. H- radio frequency source development at the Spallation Neutron Source

    SciTech Connect

    Welton, Robert F; Pennisi, Terry R; Roseberry, Ron T; Stockli, Martin P

    2012-01-01

    The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. H{sup -} beam pulses ({approx}1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, {approx}60 kW) of a copper antenna that has been encased with a thickness of {approx}0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of {approx}99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of {approx}75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance/installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to {approx}100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

  6. Characterization of a Pulse Neutron Source Yield under Field Conditions

    SciTech Connect

    Barzilov, Alexander; Novikov, Ivan; Womble, Phillip C.; Hopper, Lindsay

    2009-03-10

    Technique of rapid evaluation of a pulse neutron sources such as neutron generators under field conditions has been developed. The phoswich sensor and pulse-shape discrimination techniques have been used for the simultaneous measurements of fast neutrons, thermal neutrons, and photons. The sensor has been calibrated using activation neutron detectors and a pulse deuterium-tritium fusion neutron source.

  7. Accretion Acceleration of Neutron Stars and Effects of Gravitational Radiation

    NASA Astrophysics Data System (ADS)

    Fu, Yan-yan; Zhang, Yue-zhu; Wei, Yi-huan; Zhang, Cheng-min; Yu, Shao-hua; Pan, Yuan-yue; Guo, Yuan-qi; Wang, De-hua

    2016-01-01

    In this paper we studied the neutron star's spin acceleration in the accretion process of the neutron star binary system, and the relation how the spin period changes with the accreted mass. We analyzed further the evolutions of both magnetic field and spin period of a neutron star, and compared the modeled results with the observational data of pulsars, to show that they are consistent with each other. Based on above studies, we investigated the effect of gravitational radiation on the spin-up process of a neutron star, and derived the change rate of the neutron star's spin period in the accretion process. We also estimated the critical angular velocity Ωcr, at which the accretion torque is balanced by that of gravitational radiation, and discussed the influence of gravitational radiation on the neutron star's spin evolution.

  8. Acceleration and deceleration of neutrons: From the phase modulation of a neutron wave to a neutron turbine with refracting prisms

    SciTech Connect

    Frank, A. I.

    2013-05-15

    The possibility of the acceleration and deceleration of neutrons undergoing diffraction at a moving grating is discussed. It is shown that, in contrast to phase {pi} gratings used at the present time, which form a discrete spectrum featuring a large number of lines, a grating that has a special profile may shift, under certain conditions, the entire spectrum of diffracted neutrons. A blazing grating of this type may be used in efficiently accelerating and decelerating neutrons. As the scale of the structure becomes larger, a description based on the idea of neutron-wave refraction at its elements becomes valid, a system of moving prims forming a 'neutron turbine,' which is also able to accelerate or decelerate neutrons, being a classical limit of this enlargement.

  9. Neutronic Design Studies for the National Spallation Neutron Source (NSNS)

    SciTech Connect

    Charlton, LA

    2001-08-01

    Neutronics analyses are now in progress to support initial selection of target system design features, materials, geometry, and component sizes for the proposed Spallation Neutron Source (SNS). Calculations have been performed to determine the neutron, proton, heavy ion, and gamma-ray flux spectra as a function of time, energy, and space for the major components of the target station (target, moderators, reflectors, etc.). These analyses were also performed to establish an initial set of performance characteristics for the neutron source. The methodology, reference performance characteristics, and results of initial optimization studies involving moderator poison plate location, target material performance, reflector performance, moderator position and premoderator performance for the target system are presented in this paper.

  10. Radiation measurements at the Advanced Photon Source (APS) linear accelerator

    SciTech Connect

    Moe, H.J.; Vacca, J.H.; Veluri, V.R.; White, M.

    1995-07-01

    The injector and source of particles for the Advanced Photon Source is a 2856-MHz, S-band, electron-positron linear accelerator (linac). It produces electrons with energies up to 650 MeV or positrons with energies up to 450 MeV. Radiation measurements were made during normal electron and positron operation, as well as during several beam loss scenarios. Neutron and gamma measurements made outside the shielding walls during normal operation are within DOE guidelines. Measured radiation fields are compared to predicted levels for different conditions.

  11. Neutronic moderator design for the Spallation Neutron Source (SNS)

    SciTech Connect

    Charlton, L.A.; Barnes, J.M.; Johnson, J.O.; Gabriel, T.A.

    1998-11-01

    Neutronics analyses are now in progress to support the initial selection of moderator design parameters for the Spallation Neutron Source (SNS). The results of the initial optimization studies involving moderator poison plate location, moderator position, and premoderator performance for the target system are presented in this paper. Also presented is an initial study of the use of a composite moderator to produce a liquid methane like spectrum.

  12. MCNP Neutron Simulations: The Effectiveness of the University of Kentucky Accelerator Laboratory Pit

    NASA Astrophysics Data System (ADS)

    Jackson, Daniel; Nguyen, Thien An; Hicks, S. F.; Rice, Ben; Vanhoy, J. R.

    2015-10-01

    The design of the Van de Graaff Particle Accelerator complex at the University of Kentucky is marked by the unique addition of a pit in the main neutron scattering room underneath the neutron source and detection shielding assembly. This pit was constructed as a neutron trap in order to decrease the amount of neutron flux within the laboratory. Such a decrease of background neutron flux effectively reduces as much noise as possible in detection of neutrons scattering off of desired samples to be studied. This project uses the Monte-Carlo N-Particle Transport Code (MCNP) to model the structure of the accelerator complex, gas cell, and the detector's collimator and shielding apparatus to calculate the neutron flux in various sections of the laboratory. Simulations were completed with baseline runs of 107 neutrons of energies 4 MeV and 17 MeV, produced respectively by 3H(p,n)3He and 3H(d,n)4He source reactions. In addition, a comparison model of the complex with simply a floor and no pit was designed, and the respective neutron fluxes of both models were calculated and compared. The results of the simulations seem to affirm the validity of the pit design in significantly reducing the overall neutron flux throughout the accelerator complex, which could be used in future designs to increase the precision and reliability of data. This project was supported in part by the DOE NEUP Grant NU-12-KY-UK-0201-05 and the Donald A. Cowan Physics Institute at the University of Dallas.

  13. Cryogenic hydrogen circulation system of neutron source

    SciTech Connect

    Qiu, Y. N.; Hu, Z. J.; Wu, J. H.; Li, Q.; Zhang, Y.; Zhang, P.; Wang, G. P.

    2014-01-29

    Cold neutron sources of reactors and spallation neutron sources are classic high flux neutron sources in operation all over the world. Cryogenic fluids such as supercritical or supercooled hydrogen are commonly selected as a moderator to absorb the nuclear heating from proton beams. By comparing supercritical hydrogen circulation systems and supercooled hydrogen circulation systems, the merits and drawbacks in both systems are summarized. When supercritical hydrogen circulates as the moderator, severe pressure fluctuations caused by temperature changes will occur. The pressure control system used to balance the system pressure, which consists of a heater as an active controller for thermal compensation and an accumulator as a passive volume controller, is preliminarily studied. The results may provide guidelines for design and operation of other cryogenic hydrogen system for neutron sources under construction.

  14. DIRECTIONAL DETECTION OF A NEUTRON SOURCE.

    SciTech Connect

    VANIER, P.E.; FORMAN, L.

    2006-10-23

    Advantages afforded by the development of new directional neutron detectors and imagers are discussed. Thermal neutrons have mean free paths in air of about 20 meters, and can be effectively imaged using coded apertures. Fission spectrum neutrons have ranges greater than 100 meters, and carry enough energy to scatter at least twice in multilayer detectors which can yield both directional and spectral information. Such strategies allow better discrimination between a localized spontaneous fission source and the low, but fluctuating, level of background neutrons generated by cosmic rays. A coded aperture thermal neutron imager will be discussed as well as a proton-recoil double-scatter fast-neutron directional detector with time-of-flight energy discrimination.

  15. Maximizing the Efficacy of Accelerator-Produced Neutrons for BNCT

    SciTech Connect

    Jay F. Kunze; J. Frank Harmon; Rajat Kudchadker; Chad L. Lee

    2000-06-04

    Production of neutrons for boron neutron capture therapy (BNCT) treatment of malignant brain tumors will best be served if the neutrons can be produced by accelerators rather than nuclear reactors. The neutron production reaction that has been most thoroughly examined using accelerators is {sup 7}Li(n, p){sup 7}Be, generally on a thick lithium target. The threshold for this reactor is 1.88 MeV, and the yield curve for neutron production rises quite rapidly up to 2.3 MeV, where the positive slope is reduced significantly. In considering the design of a neutron production device, it has been traditional to use proton energies in the 2.4- to 2.5-MeV range. Over the last several years, our group has been working with lower-energy protons, just above the threshold for neutron production. The advantage is that the neutrons produced would have much lower energy and hence need much less moderator. The principal disadvantage of operating at these near-threshold energies is that the yield from the target is substantially reduced from that at or near 2.5-MeV proton energy. Table I shows the results of calculations to find an optimum energy for 3-mA proton beam on target. In general, we have concluded that 1.96 to 1.98 MeV is probably optimum for a tumor 5 cm below the skull.

  16. High Brightness Neutron Source for Radiography

    SciTech Connect

    Cremer, J. T.; Piestrup, Melvin, A.; Gary, Charles, K.; Harris, Jack, L. Williams, David, J.; Jones, Glenn, E.; Vainionpaa, J. , H.; Fuller, Michael, J.; Rothbart, George, H.; Kwan, J., W.; Ludewigt, B., A.; Gough, R.., A..; Reijonen, Jani; Leung, Ka-Ngo

    2008-12-08

    This research and development program was designed to improve nondestructive evaluation of large mechanical objects by providing both fast and thermal neutron sources for radiography. Neutron radiography permits inspection inside objects that x-rays cannot penetrate and permits imaging of corrosion and cracks in low-density materials. Discovering of fatigue cracks and corrosion in piping without the necessity of insulation removal is possible. Neutron radiography sources can provide for the nondestructive testing interests of commercial and military aircraft, public utilities and petrochemical organizations. Three neutron prototype neutron generators were designed and fabricated based on original research done at the Lawrence Berkeley National Laboratory (LBNL). The research and development of these generators was successfully continued by LBNL and Adelphi Technology Inc. under this STTR. The original design goals of high neutron yield and generator robustness have been achieved, using new technology developed under this grant. In one prototype generator, the fast neutron yield and brightness was roughly 10 times larger than previously marketed neutron generators using the same deuterium-deuterium reaction. In another generator, we integrate a moderator with a fast neutron source, resulting in a high brightness thermal neutron generator. The moderator acts as both conventional moderator and mechanical and electrical support structure for the generator and effectively mimics a nuclear reactor. In addition to the new prototype generators, an entirely new plasma ion source for neutron production was developed. First developed by LBNL, this source uses a spiral antenna to more efficiently couple the RF radiation into the plasma, reducing the required gas pressure so that the generator head can be completely sealed, permitting the possible use of tritium gas. This also permits the generator to use the deuterium-tritium reaction to produce 14-MeV neutrons with increases

  17. Accelerator-driven boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Edgecock, Rob

    2014-05-01

    Boron Neutron Capture Therapy is a binary treatment for certain types of cancer. It works by loading the cancerous cells with a boron-10 carrying compound. This isotope has a large cross-section for thermal neutrons, the reaction producing a lithium nucleus and alpha particle that kill the cell in which they are produced. Recent studies of the boron carrier compound indicate that the uptake process works best in particularly aggressive cancers. Most studied is glioblastoma multiforme and a trial using a combination of BNCT and X-ray radiotherapy has shown an increase of nearly a factor of two in mean survival over the state of the art. However, the main technical problem with BNCT remains producing a sufficient flux of neutrons for a reasonable treatment duration in a hospital environment. This paper discusses this issue.

  18. Fast Neutron Radiography at an RFQ Accelerator System

    NASA Astrophysics Data System (ADS)

    Daniels, G. C.; Franklyn, C. B.; Dangendorf, V.; Buffler, A.; Bromberger, B.

    This work introduces the Necsa Radio Frequency Quadrupole (RFQ) accelerator facility and its work concerning fast neutron radiography (FNR). Necsa operates a 4-5 MeV, up to 50 mA deuteron RFQ. The previous deuterium gas target station has been modified to enable producing a white neutron beam employing a solid B4C target. Furthermore, the high energy beam transport (HEBT) section is under adjustment to achieve a longer flight-path and a better focus. This work presents an overview of the facility, the modifications made, and introduces past and ongoing neutron radiography investigations.

  19. A low-neutron background slow-positron source.

    SciTech Connect

    White, M. M.

    1998-10-09

    The addition of a thermionic rf gun [1] and a photocathode rf gun will allow the Advanced Photon Source (APS) linear accelerator (linac) [2] [3] to become a free-electron laser (FEL) driver [4]. As the FEL project progresses, the existing high-charge DC thermionic gun will no longer be critical to APS operation and could be used to generate high-energy or low-energy electrons to drive a slow-positron source. We investigated possibilities to create a useful low-energy source that could operate semi-independently and would have a low neutron background.

  20. Analysis of accelerator based neutron spectra for BNCT using proton recoil spectroscopy

    SciTech Connect

    Wielopolski, L.; Ludewig, H.; Powell, J.R.; Raparia, D.; Alessi, J.G.; Lowenstein, D.I.

    1999-03-01

    Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase 1/2 clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra, alternative neutron sources are being contemplated for wider implementation of this modality in a hospital environment. For example, accelerator based neutron sources offer the possibility of tailoring the neutron beams, in terms of improved depth-dose distributions, to the individual and offer, with relative ease, the capability of modifying the neutron beam energy and port size. In previous work new concepts for compact accelerator/target configuration were published. In this work, using the Van de Graaff accelerator the authors have explored different materials for filtering and reflecting neutron beams produced by irradiating a thick Li target with 1.8 to 2.5 MeV proton beams. However, since the yield and the maximum neutron energy emerging from the Li-7(p,n)Be-7 reaction increase with increase in the proton beam energy, there is a need for optimization of the proton energy versus filter and shielding requirements to obtain the desired epithermal neutron beam. The MCNP-4A computer code was used for the initial design studies that were verified with benchmark

  1. ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY

    SciTech Connect

    WIELOPOLSKI,L.; LUDEWIG,H.; POWELL,J.R.; RAPARIA,D.; ALESSI,J.G.; LOWENSTEIN,D.I.

    1998-11-06

    Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider implementation of this modality in a hospital environment. For example, accelerator based neutron sources offer the possibility of tailoring the neutron beams, in terms of improved depth-dose distributions, to the individual and offer, with relative ease, the capability of modifying the neutron beam energy and port size. In previous work new concepts for compact accelerator/target configuration were published. In this work, using the Van de Graaff accelerator the authors have explored different materials for filtering and reflecting neutron beams produced by irradiating a thick Li target with 1.8 to 2.5 MeV proton beams. However, since the yield and the maximum neutron energy emerging from the Li-7(p,n)Be-7 reaction increase with increase in the proton beam energy, there is a need for optimization of the proton energy versus filter and shielding requirements to obtain the desired epithermal neutron beam. The MCNP-4A computer code was used for the initial design studies that were verified with benchmark

  2. Negative hydrogen ion sources for accelerators

    SciTech Connect

    Moehs, D.P.; Peters, J.; Sherman, J.; /Los Alamos

    2005-08-01

    A variety of H{sup -} ion sources are in use at accelerator laboratories around the world. A list of these ion sources includes surface plasma sources with magnetron, Penning and surface converter geometries as well as magnetic-multipole volume sources with and without cesium. Just as varied is the means of igniting and maintaining magnetically confined plasmas. Hot and cold cathodes, radio frequency, and microwave power are all in use, as well as electron tandem source ignition. The extraction systems of accelerator H{sup -} ion sources are highly specialized utilizing magnetic and electric fields in their low energy beam transport systems to produce direct current, as well as pulsed and/or chopped beams with a variety of time structures. Within this paper, specific ion sources utilized at accelerator laboratories shall be reviewed along with the physics of surface and volume H{sup -} production in regard to source emittance. Current research trends including aperture modeling, thermal modeling, surface conditioning, and laser diagnostics will also be discussed.

  3. Particle acceleration in axisymmetric, magnetized neutron stars

    NASA Technical Reports Server (NTRS)

    Baker, K. B.; Sturrock, P. A.

    1977-01-01

    The potential drop in the polar cap region of a rotating, magnetized neutron star is found assuming that the magnetic field is dipolar, with the field aligned (or anti-aligned) with the rotation axis. The curvature of the field lines is of critical importance. Charge flow is assumed to be along magnetic field lines. The electric field has a maximum at radius 1.5 R and the magnitude and functional form of the current is determined.

  4. Neutron science opportunities at pulsed spallation neutron sources

    SciTech Connect

    Carpenter, J.M.

    1996-12-31

    Using the IPNS Upgrade plan developed at Argonne National Laboratory as a worked example of the design of a pulsed spallation neutron source, this paper explores some of the scientific applications of an advanced facility for materials science studies and the instrumentation for those purposes.

  5. Calculations of neutron shielding data for 10-100 MeV proton accelerators.

    PubMed

    Chen, C C; Sheu, R J; Jian, S H

    2005-01-01

    The characteristics of neutron sources and their attenuation in concrete were investigated in detail for protons with energies ranging from 10 to 100 MeV striking on target materials of C, N, Al, Fe, Cu and W. A two-step approach was adopted: thick-target double-differential neutron yields were first calculated from the (p, xn) cross sections recommended in the ICRU Report 63; further, transport simulations of those neutrons in concrete were performed by using the FLUKA Monte Carlo code. The purpose of this study is to provide reasonably accurate parameters for shielding design for 10-100 MeV proton accelerators. Source terms and the corresponding attenuation lengths in concrete for several target materials are given as a function of proton energies and neutron emission angles. PMID:16604637

  6. Iterative Reconstruction of Coded Source Neutron Radiographs

    SciTech Connect

    Santos-Villalobos, Hector J; Bingham, Philip R; Gregor, Jens

    2012-01-01

    Use of a coded source facilitates high-resolution neutron imaging but requires that the radiographic data be deconvolved. In this paper, we compare direct deconvolution with two different iterative algorithms, namely, one based on direct deconvolution embedded in an MLE-like framework and one based on a geometric model of the neutron beam and a least squares formulation of the inverse imaging problem.

  7. Advanced Neutron Source: The users' perspective

    SciTech Connect

    Peretz, F.J.

    1990-01-01

    User experiments will cover fields such as activation analysis of pollutants, irradiation of materials for the fusion program, and neutron scattering studies of materials as diverse as viruses, aerospace composites, and superconductors. Production capabilities must also be provided for the production of isotopes, especially of transuranic elements. The different ways in which these research areas and their required infrastructure influence the design of the Advanced Neutron Source will be the subject of this paper.

  8. High neutronic efficiency, low current targets for accelerator-based BNCT applications

    SciTech Connect

    Powell, J.R.; Ludewig, H.; Todosow, M.

    1998-08-01

    The neutronic efficiency of target/filters for accelerator-based BNCT applications is measured by the proton current required to achieve a desirable neutron current at the treatment port (10{sup 9} n/cm{sup 2}/s). In this paper the authors describe two possible targeyt/filter concepts wihch minimize the required current. Both concepts are based on the Li-7 (p,n)Be-7 reaction. Targets that operate near the threshold energy generate neutrons that are close tothe desired energy for BNCT treatment. Thus, the filter can be extremely thin ({approximately} 5 cm iron). However, this approach has an extremely low neutron yield (n/p {approximately} 1.0({minus}6)), thus requiring a high proton current. The proposed solutino is to design a target consisting of multiple extremely thin targets (proton energy loss per target {approximately} 10 keV), and re-accelerate the protons between each target. Targets operating at ihgher proton energies ({approximately} 2.5 MeV) have a much higher yield (n/p {approximately} 1.0({minus}4)). However, at these energies the maximum neutron energy is approximately 800 keV, and thus a neutron filter is required to degrade the average neutron energy to the range of interest for BNCT (10--20 keV). A neutron filter consisting of fluorine compounds and iron has been investigated for this case. Typically a proton current of approximately 5 mA is required to generate the desired neutron current at the treatment port. The efficiency of these filter designs can be further increased by incorporating neutron reflectors that are co-axial with the neutron source. These reflectors are made of materials which have high scattering cross sections in the range 0.1--1.0 MeV.

  9. Miniature accelerator-driven gamma source concept.

    SciTech Connect

    Garnett, R. W.; Chan, K. D.; Wangler, Thomas P.,; Wood R. L.; Carlsten, B. E.; Kirbie, H. C.

    2003-01-01

    Recent developments in W-band (-100 GHz) traveling wave tube technology at Los Alarnos may lead to a compact high-power W-band RE source. A conceptual design of a compact 8-MeV electron linac that codd be powered by this source is presented, including electromagnetic structure calculations, proposed rnicrojbbrication and manufacturing methods, supporting calculations to estimate accelerator performance, and gumma production rates based on preliminary target geometries and expected output beam current.

  10. The SPARC linear accelerator based terahertz source

    SciTech Connect

    Chiadroni, E.; Bacci, A.; Bellaveglia, M.; Boscolo, M.; Castellano, M.; Cultrera, L.; Di Pirro, G.; Ferrario, M.; Ficcadenti, L.; Filippetto, D.; Gatti, G.; Pace, E.; Rossi, A. R.; Vaccarezza, C.; Catani, L.; Cianchi, A.; Marchetti, B.; Mostacci, A.; Palumbo, L.; Ronsivalle, C.; and others

    2013-03-04

    Ultra-short electron beams, produced through the velocity bunching compression technique, are used to drive the SPARC linear accelerator based source, which relies on the emission of coherent transition radiation in the terahertz range. This paper reports on the main features of this radiation, as terahertz source, with spectral coverage up to 5 THz and pulse duration down to 200 fs, with an energy per pulse of the order of several micro-joule, and as electron beam longitudinal diagnostics.

  11. Los Alamos Neutron Science Center (LANSCE) accelerator timing system upgrade

    SciTech Connect

    Rybarcyk, L.J.; Shelley, F.E. Jr.

    1997-10-01

    The Los Alamos Neutron Science Center (LANSCE) 800 MeV proton linear accelerator (linac) operates at a maximum repetition rate of twice the AC power line frequency, i.e. 120 Hz. The start of each machine cycle occurs a fixed delay after each zero-crossing of the AC line voltage. Fluctuations in the AC line frequency and phase are therefore present on all linac timing signals. Proper beam acceleration along the linac requires that the timing signals remain well synchronized to the AC line. For neutron chopper spectrometers, e.g., PHAROS at the Manuel Lujan Jr. Neutron Scattering Center, accurate neutron energy selection requires that precise synchronization be maintained between the beam-on-target arrival time and the neutron chopper rotor position. This is most easily accomplished when the chopper is synchronized to a stable, fixed frequency signal. A new zero-crossing circuit which employs a Phase-Locked Loop (PLL) has been developed to increase the phase and frequency stability of the linac timing signals and thereby improve neutron chopper performance while simultaneously maintaining proper linac operation. Results of timing signal data analysis and modeling and a description of the PLL circuit are presented.

  12. Accelerator-driven X-ray Sources

    SciTech Connect

    Nguyen, Dinh Cong

    2015-11-09

    After an introduction which mentions x-ray tubes and storage rings and gives a brief review of special relativity, the subject is treated under the following topics and subtopics: synchrotron radiation (bending magnet radiation, wiggler radiation, undulator radiation, brightness and brilliance definition, synchrotron radiation facilities), x-ray free-electron lasers (linac-driven X-ray FEL, FEL interactions, self-amplified spontaneous emission (SASE), SASE self-seeding, fourth-generation light source facilities), and other X-ray sources (energy recovery linacs, Inverse Compton scattering, laser wakefield accelerator driven X-ray sources. In summary, accelerator-based light sources cover the entire electromagnetic spectrum. Synchrotron radiation (bending magnet, wiggler and undulator radiation) has unique properties that can be tailored to the users’ needs: bending magnet and wiggler radiation is broadband, undulator radiation has narrow spectral lines. X-ray FELs are the brightest coherent X-ray sources with high photon flux, femtosecond pulses, full transverse coherence, partial temporal coherence (SASE), and narrow spectral lines with seeding techniques. New developments in electron accelerators and radiation production can potentially lead to more compact sources of coherent X-rays.

  13. The Spallation Neutron Source: A powerful tool for materials research

    SciTech Connect

    Mason, Thom; Anderson, Ian S; Ankner, John Francis; Egami, Takeshi; Ekkebus, Allen E; Herwig, Kenneth W; Hodges, Jason P; Horak, Charlie M; Horton, Linda L; Klose, Frank Richard; Mesecar, Andrew D.; Myles, Dean A A; Ohl, M.; Zhao, Jinkui

    2006-01-01

    When completed in 2006, the Spallation Neutron Source (SNS) will use an accelerator to produce the most intense beams of pulsed neutrons in the world. This unique facility is being built by a collaboration of six US Department of Energy laboratories and will serve a diverse community of users drawn from academia, industry, and government labs. The project continues on schedule and within budget, with commissioning and installation of all systems going well. Installation of 14 state-of-the-art instruments is under way, and design work is being completed for several others. These new instruments will enable inelastic and elastic-scattering measurements across a broad range of science such as condensed-matter physics, chemistry, engineering materials, biology, and beyond. Neutron Science at SNS will be complemented by research opportunities at several other facilities under way at Oak Ridge National Laboratory.

  14. A Photo-neutron Source for a Sub-Critical Nuclear Reactor Program

    SciTech Connect

    Reda, M.A.; Harmon, J.F.; Sadineni, S.B.

    2003-08-26

    Experiments to benchmark photo-neutron production calculations for an Accelerator Driven Sub-Critical System (ADS) are described. A photo-nuclear based neutron source with output > 1013 n/sec has been proposed as a driver for a program using the sub-critical assembly at Idaho State University. The program is intended to study ADS control issues arising from coupling an accelerator neutron source with a sub-critical assembly. The experiments were performed using the 20 MeV electron linear accelerator at the Idaho Accelerator Center (IAC). Results of calculations, that were made using ACCEPT, PINP, MCNP, and MCNPX codes to optimize photo-nuclear based neutron conversion targets, are compared to experimental data for a single energy measurement.

  15. Measuring and monitoring KIPT Neutron Source Facility Reactivity

    SciTech Connect

    Cao, Yan; Gohar, Yousry; Zhong, Zhaopeng

    2015-08-01

    Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on developing and constructing a neutron source facility at Kharkov, Ukraine. The facility consists of an accelerator-driven subcritical system. The accelerator has a 100 kW electron beam using 100 MeV electrons. The subcritical assembly has keff less than 0.98. To ensure the safe operation of this neutron source facility, the reactivity of the subcritical core has to be accurately determined and continuously monitored. A technique which combines the area-ratio method and the flux-to-current ratio method is purposed to determine the reactivity of the KIPT subcritical assembly at various conditions. In particular, the area-ratio method can determine the absolute reactivity of the subcritical assembly in units of dollars by performing pulsed-neutron experiments. It provides reference reactivities for the flux-to-current ratio method to track and monitor the reactivity deviations from the reference state while the facility is at other operation modes. Monte Carlo simulations are performed to simulate both methods using the numerical model of the KIPT subcritical assembly. It is found that the reactivities obtained from both the area-ratio method and the flux-to-current ratio method are spatially dependent on the neutron detector locations and types. Numerical simulations also suggest optimal neutron detector locations to minimize the spatial effects in the flux-to-current ratio method. The spatial correction factors are calculated using Monte Carlo methods for both measuring methods at the selected neutron detector locations. Monte Carlo simulations are also performed to verify the accuracy of the flux-to-current ratio method in monitoring the reactivity swing during a fuel burnup cycle.

  16. Directional measurements for sources of fission neutrons

    SciTech Connect

    Byrd, R.C.; Auchampaugh, G.F.; Feldman, W.C.

    1993-11-01

    Although penetrating neutron and gamma-ray emissions arguably provide the most effective signals for locating sources of nuclear radiation, their relatively low fluxes make searching for radioactive materials a tedious process. Even assuming lightly shielded sources and detectors with large areas and high efficiencies, estimated counting times can exceed several minutes for source separations greater than ten meters. Because determining the source position requires measurements at several locations, each with its own background, the search procedure can be lengthy and difficult to automate. Although directional measurements can be helpful, conventional collimation reduces count rates and increases the detector size and weight prohibitively, especially for neutron instruments. We describe an alternative approach for locating radiation sources that is based on the concept of a polarized radiation field. In this model, the presence of a source adds a directional component to the randomly oriented background radiation. The net direction of the local field indicates the source angle, and the magnitude provides an estimate of the distance to the source. The search detector is therefore seen as a device that responds to this polarized radiation field. Our proposed instrument simply substitutes segmented detectors for conventional single-element ones, so it requires little or no collimating material or additional weight. Attenuation across the detector creates differences in the count rates for opposite segments, whose ratios can be used to calculate the orthogonal components of the polarization vector. Although this approach is applicable to different types of radiation and detectors, in this report we demonstrate its use for sources of fission neutrons by using a prototype fast-neutron detector, which also provides background-corrected energy spectra for the incident neutrons.

  17. Iterative Reconstruction of Coded Source Neutron Radiographs

    SciTech Connect

    Santos-Villalobos, Hector J; Bingham, Philip R; Gregor, Jens

    2013-01-01

    Use of a coded source facilitates high-resolution neutron imaging through magnifications but requires that the radiographic data be deconvolved. A comparison of direct deconvolution with two different iterative algorithms has been performed. One iterative algorithm is based on a maximum likelihood estimation (MLE)-like framework and the second is based on a geometric model of the neutron beam within a least squares formulation of the inverse imaging problem. Simulated data for both uniform and Gaussian shaped source distributions was used for testing to understand the impact of non-uniformities present in neutron beam distributions on the reconstructed images. Results indicate that the model based reconstruction method will match resolution and improve on contrast over convolution methods in the presence of non-uniform sources. Additionally, the model based iterative algorithm provides direct calculation of quantitative transmission values while the convolution based methods must be normalized base on known values.

  18. 10 CFR 39.55 - Tritium neutron generator target sources.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Tritium neutron generator target sources. 39.55 Section 39... Equipment § 39.55 Tritium neutron generator target sources. (a) Use of a tritium neutron generator target...) Use of a tritium neutron generator target source, containing quantities exceeding 1,110 GBg or in...

  19. 10 CFR 39.55 - Tritium neutron generator target sources.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Tritium neutron generator target sources. 39.55 Section 39... Equipment § 39.55 Tritium neutron generator target sources. (a) Use of a tritium neutron generator target...) Use of a tritium neutron generator target source, containing quantities exceeding 1,110 GBg or in...

  20. 10 CFR 39.55 - Tritium neutron generator target sources.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Tritium neutron generator target sources. 39.55 Section 39... Equipment § 39.55 Tritium neutron generator target sources. (a) Use of a tritium neutron generator target...) Use of a tritium neutron generator target source, containing quantities exceeding 1,110 GBg or in...

  1. 10 CFR 39.55 - Tritium neutron generator target sources.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Tritium neutron generator target sources. 39.55 Section 39... Equipment § 39.55 Tritium neutron generator target sources. (a) Use of a tritium neutron generator target...) Use of a tritium neutron generator target source, containing quantities exceeding 1,110 GBg or in...

  2. 10 CFR 39.55 - Tritium neutron generator target sources.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Tritium neutron generator target sources. 39.55 Section 39... Equipment § 39.55 Tritium neutron generator target sources. (a) Use of a tritium neutron generator target...) Use of a tritium neutron generator target source, containing quantities exceeding 1,110 GBg or in...

  3. Electron accelerator-driven photoneutron source for clinical environments

    NASA Astrophysics Data System (ADS)

    Dale, Gregory Edward

    There are several potential uses for a high-flux thermal neutron source in both industrial and clinical applications. The viable commercial implementation of these applications requires a low cost, high-flux thermal neutron generator suitable for installation in industrial and clinical environments. This dissertation describes the MCNP modeling results of a high-flux thermal neutron source driven with an electron accelerator. An electron linac, fitted with a standard x-ray converter, can produce high neutron yields in materials with low photonuclear threshold energies, such as D and 9Be. Calculations were performed using the Monte Carlo for N-Particle (MCNP) transport code. Modeling results indicate that a 10 MeV, 10 kW electron linac can produce on the order of 1012 n/s in a heavy water photoneutron target. A 40 cm radius, 60 cm long cylindrical heavy water photoneutron target has a photoneutron production rate equal to 5.7 x 1012 n/s. The thermal neutron flux in an unreflected, 40 cm radius, 60 cm long heavy water target is calculated to be 9.81 x 109 n/cm 2/s. The sensitivity of these answers to heavy water purity was investigated, specifically, the dilution of heavy water with light water. It was shown that the peak thermal neutron flux in an unreflected target was not adversely effected by dilution up to a light water weight fraction of 25%. The final design consists of a 40 cm radius, 60 cm long cylindrical photonuclear target reflected on all sides with 20 cm of polyethylene. The polyethylene reflector increases the maximum thermal neutron flux by 66%, to 1.40 x 1010 n/cm2/s using a 10 MeV, 1 mA (10 kW) electron linac. At this flux level the device is capable of producing 831 muCi/mg of 165Dy from natural dysprosium. The device is capable of producing 160 muCi/mg of 198Au at this flux. The neutron shielding required for the device consists of 5 cm of 5% borated polyethylene (BPE) on the front of the device, 4.25 cm of BPE on the side, and 8.5 cm of BPE on

  4. Material issues relating to high power spallation neutron sources

    NASA Astrophysics Data System (ADS)

    Futakawa, M.

    2015-02-01

    Innovative researches using neutrons are being performed at the Materials and Life Science Experimental Facility (MLF) at the Japan Proton Accelerator Research Complex (J-PARC), in which a mercury target system is installed for MW-class pulse spallation neutron sources. In order to produce neutrons by the spallation reaction, proton beams are injected into the mercury target. At the moment, when the intense proton beam hits the target, pressure waves are generated in mercury because of the abrupt heat deposition. The pressure waves interact with the target vessel, leading to negative pressure that may cause cavitation along the vessel wall, i.e. on the interface between liquid and solid metals. On the other hand, the structural materials are subjected to irradiation damage due to protons and neutrons, very high cycle fatigue damages and so-called "liquid metal embrittlement". That is, the structural materials must be said to be exposed to the extremely severe environments. In the paper, research and development relating to the material issues in the high power spallation neutron sources that has been performed so far at J-PARC is summarized.

  5. Target studies for accelerator-based boron neutron capture therapy

    SciTech Connect

    Powell, J.R.; Ludewig, H.; Todosow, M.; Reich, M.

    1996-03-01

    Two new concepts, NIFTI and DISCOS, are described. These concepts enable the efficient production of epithermal neutrons for BNCT (Boron Neutron Capture Therapy) medical treatment, utilizing a low current, low energy proton beam impacting on a lithium target. The NIFTI concept uses an iron layer that strongly impedes the transmission of neutrons with energies above 24 KeV. Lower energy neutrons readily pass through this iron ``filter``, which has a deep ``window`` in its scattering cross section at 24 KeV. The DISCOS concept uses a rapidly rotating, high g disc to create a series of thin ({approximately} 1 micron thickness) liquid lithium targets in the form of continuous films through which the proton beam passes. The average energy lost by a proton as it passes through a single target is small, approximately 10 KeV. Between the targets, the proton beam is reaccelerated by an applied DC electric field. The DISCOS approach enables the accelerator -- target facility to operate with a beam energy only slightly above the threshold value for neutron production -- resulting in an output beam of low-energy epithermal neutrons -- while achieving a high yield of neutrons per milliamp of proton beam current.

  6. International workshop on plasma-based neutron sources

    SciTech Connect

    1996-12-09

    The workshop was devoted to discussion of the status and future directions of work on plasma-based neutron sources. The workshop presentations demonstrated significant progress in development of the concepts of these sources and in broadening the required data base. Two main groups of neutron source designs were presented at the workshop: tokamak-based and mirror-based. Designs of the tokamak- based devices use the extensive data base generated during decades of tokamak research. Their plasma physics performance can be predicted with a high degree of confidence. On the other hand, they are relatively large and expensive, and best suited for Volumetric Neutron Sources (VNSes) or other large scale test facilities. They also have the advantage of being on the direct path to a power- producing reactor as presently conceived, although alternatives to the tokamak are presently receiving serious consideration for a reactor. The data base for the mirror-based group of plasma sources is less developed, but they are generally more flexible and, with appropriate selection of parameters, have the potential to be developed as compact Accelerated Test Facilities (ATFs) as well as full-scale VNSes. Also discussed at the workshop were some newly proposed but potentially promising concepts, like those based on the flow-through pinch and electrostatic ion-beam sources.

  7. Selective Deuteron Acceleration and Neutron Production on the Vulcan PW Laser

    NASA Astrophysics Data System (ADS)

    Krygier, A. G.; Morrison, J. T.; Freeman, R. R.; Ahmed, H.; Green, J. A.; Alejo, A.; Kar, S.; Vassura, L.

    2014-10-01

    Fast neutron sources are important for a variety of applications including radiography and the detection of sensitive materials. Here we report on the results of an experiment using the Vulcan PW laser at Rutherford Appleton Laboratory to produce a nearly pure deuterium ion beam via Target Normal Sheath Acceleration. The typical contaminants are suppressed by freezing a μ m's thick layer of heavy water vapor (D2 O) onto a cryogenic target during the shot sequence. Neutrons were generated by colliding the accelerated deuterons were into secondary targets made of deuterated plastic in the pitcher-catcher arrangement. Absolute yields for deuterium ions and neutrons are reported. This work is supported by DOE Contract DE-FC02-04ER54789.

  8. The continued development of the Spallation Neutron Source external antenna H{sup -} ion source

    SciTech Connect

    Welton, R. F.; Carmichael, J.; Fuga, R.; Goulding, R. H.; Han, B.; Kang, Y.; Lee, S. W.; Murray, S. N.; Pennisi, T.; Potter, K. G.; Santana, M.; Stockli, M. P.; Desai, N. J.

    2010-02-15

    The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility, currently in the process of ramping up neutron production. In order to ensure that the SNS will meet its operational commitments as well as provide for future facility upgrades with high reliability, we are developing a rf-driven, H{sup -} ion source based on a water-cooled, ceramic aluminum nitride (AlN) plasma chamber. To date, early versions of this source have delivered up to 42 mA to the SNS front end and unanalyzed beam currents up to {approx}100 mA (60 Hz, 1 ms) to the ion source test stand. This source was operated on the SNS accelerator from February to April 2009 and produced {approx}35 mA (beam current required by the ramp up plan) with availability of {approx}97%. During this run several ion source failures identified reliability issues, which must be addressed before the source re-enters production: plasma ignition, antenna lifetime, magnet cooling, and cooling jacket integrity. This report discusses these issues, details proposed engineering solutions, and notes progress to date.

  9. Powder diffraction in materials science using the KENS cold-neutron source

    SciTech Connect

    Kamiyama, T.; Oikawa, K.; Akiba, E.

    1997-12-01

    Since superconductivity fever spread around the world, neutron powder diffraction has become very popular and been widely used by crystallographers, physicists, chemists, mineralogists, and materials scientists. The purpose of present paper is to show, firstly, important characteristics of time-of-flight TOF powder diffraction using cold-neutron source in the study of materials science, and, secondly, recent studies on the structure and function of batteries at the Neutron Science Laboratory (KENS) in the High Energy Accelerator Research Organization (KEK).

  10. Propagation characteristics of neutrons leaking from the accelerator facilities.

    PubMed

    Kitaichi, Masatoshi; Sawamura, Sadashi; Wakisaka, Masashi; Kaneko, Junichi H; Ochiai, Kentaro; Nishitani, Takeo; Sawamura, Teruko

    2004-01-01

    In this study spatial and time distribution of neutrons leaking from Hokkaido University 45 MeV Electron Linac facility have measured and compared with the Monte Carlo simulations. The neutron transport processes inside and outside the facility building has been simulated using MCNP. The neutrons have measured by BF3 counters and 3He counters with polyethylene moderators up to the distance of 330 m from the facility. The spatial distribution of ambient dose equivalent converted from the counts has been compared with the simulation. The distribution estimated from the counts by the BF3 counter has been shown fairly good agreement with the calculation. The spatial distribution of counts obtained at the 45 MeV Electron Linac facility has been compared with that obtained at the Fusion Neutronics Source (FNS) facility of JAERI. The difference between the propagation characteristics of neutrons leaking from those facilities has been discussed. PMID:15353739

  11. ITEP subcritical neutron generator driven by charged particle accelerator

    SciTech Connect

    Shvedov, Oleg V.; Chuvilo, Ivan V.; Kulikov, Evgeny V.; Vasiliev, Valery V.; Igumnov, Mikhail M.; Kozodaev, Alexander M.; Volkov, Evgeny B.; Lopatkin, Alexander V.

    1995-09-15

    A research facility prototype including a combination of a linear accelerator, a neutron generating target, a subcritical multiplying system is discussed. Principles of the nuclear safety ensuring and means of its attainment for Subcritical Neutron Generator are considered. The scheme of the multiplying is shown. The assembly will be mounted in the body of the partly dismantled ITEP HWR. Requirements for subcritical assembly are worked out and their feasibility within the framework of the heavy-water blanket is shown. The facility's application as a full-scale model of more powerful installations of this kind and for fundamental experimental research has been investigated.

  12. Enrico Fermi's Discovery of Neutron-Induced Artificial Radioactivity: Neutrons and Neutron Sources

    NASA Astrophysics Data System (ADS)

    Guerra, Francesco; Leone, Matteo; Robotti, Nadia

    2006-09-01

    We reconstruct and analyze the path leading from James Chadwick’s discovery of the neutron in February 1932 through Frédéric Joliot and Irène Curie’s discovery of artificial radioactivity in January 1934 to Enrico Fermi’s discovery of neutron-induced artificial radioactivity in March 1934. We show, in particular, that Fermi’s innovative construction and use of radon-beryllium neutron sources permitted him to make his discovery.

  13. High-power liquid-lithium target prototype for accelerator-based boron neutron capture therapy.

    PubMed

    Halfon, S; Paul, M; Arenshtam, A; Berkovits, D; Bisyakoev, M; Eliyahu, I; Feinberg, G; Hazenshprung, N; Kijel, D; Nagler, A; Silverman, I

    2011-12-01

    A prototype of a compact Liquid-Lithium Target (LiLiT), which will possibly constitute an accelerator-based intense neutron source for Boron Neutron Capture Therapy (BNCT) in hospitals, was built. The LiLiT setup is presently being commissioned at Soreq Nuclear Research Center (SNRC). The liquid-lithium target will produce neutrons through the (7)Li(p,n)(7)Be reaction and it will overcome the major problem of removing the thermal power generated using a high-intensity proton beam (>10 kW), necessary for sufficient neutron flux. In off-line circulation tests, the liquid-lithium loop generated a stable lithium jet at high velocity, on a concave supporting wall; the concept will first be tested using a high-power electron beam impinging on the lithium jet. High intensity proton beam irradiation (1.91-2.5 MeV, 2-4 mA) will take place at Soreq Applied Research Accelerator Facility (SARAF) superconducting linear accelerator currently in construction at SNRC. Radiological risks due to the (7)Be produced in the reaction were studied and will be handled through a proper design, including a cold trap and appropriate shielding. A moderator/reflector assembly is planned according to a Monte Carlo simulation, to create a neutron spectrum and intensity maximally effective to the treatment and to reduce prompt gamma radiation dose risks. PMID:21459008

  14. Secondary electron ion source neutron generator

    DOEpatents

    Brainard, John P.; McCollister, Daryl R.

    1998-01-01

    A neutron generator employing an electron emitter, an ion source bombarded by the electrons from the electron emitter, a plasma containment zone, and a target situated between the plasma containment zone and the electron emitter. The target contains occluded deuterium, tritium, or a mixture thereof

  15. Secondary electron ion source neutron generator

    DOEpatents

    Brainard, J.P.; McCollister, D.R.

    1998-04-28

    A neutron generator employing an electron emitter, an ion source bombarded by the electrons from the electron emitter, a plasma containment zone, and a target situated between the plasma containment zone and the electron emitter is disclosed. The target contains occluded deuterium, tritium, or a mixture thereof. 4 figs.

  16. Status Report on the Spallation Neutron Source

    SciTech Connect

    Gabriel, T.A.

    1998-10-12

    The purpose of the Spallation Neutron Source Project (SNS) is to generate low-energy neutrons (ambient [{approximately}200 meV] and cold [{approximately}50 meV]) which can be used by up to 18 neutron beam lines to study the structure and functionality of materials. The neutrons are generated by the spallation process initiated by the interactions of 1-GeV protons with a Hg target. These neutrons are reflected by a Pb reflector and are moderated by 2 water (ambient) and 2 super critical hydrogen (cryogenic) moderators. The pulse structure for the 1 MW proton beam is 60 Hertz and < 0.7 {micro}s/pulse. The facility must be upgradable to higher power levels (2- and 4- MW) with minimal operational interruptions. Although not included in the current funding or baseline, a second target station and associated support structure which will be designed to utilize cold neutrons is also considered to be an upgrade that must be incorporated with minimal impact on operations.

  17. Cold moderators for pulsed neutron sources

    SciTech Connect

    Carpenter, J.M.

    1990-01-01

    This paper reviews cold moderators in pulsed neutron sources and provides details of the performance of different cold moderator materials and configurations. Analytical forms are presented which describe wavelength spectra and emission time distributions. Several types of cooling arrangements used in pulsed source moderators are described. Choices of materials are surveyed. The author examines some of the radiation damage effects in cold moderators, including the phenomenon of burping'' in irradiated cold solid methane. 9 refs., 15 figs., 4 tabs.

  18. COHERENT at the Spallation Neutron Source

    NASA Astrophysics Data System (ADS)

    Raybern, Justin; Scholberg, Kate

    2015-04-01

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, Tennessee, provides an intense isotropic flux of neutrinos in the few tens-of-MeV range, with a sharply-pulsed timing structure which is beneficial for background rejection. This talk will describe how the SNS source can be used for a measurement of coherent elastic neutrino-nucleus scattering (CEvNS), the physics reach of such a measurement, and the status of COHERENT, the planned experimental program.

  19. 5 MW pulsed spallation neutron source, Preconceptual design study

    SciTech Connect

    Not Available

    1994-06-01

    This report describes a self-consistent base line design for a 5 MW Pulsed Spallation Neutron Source (PSNS). It is intended to establish feasibility of design and as a basis for further expanded and detailed studies. It may also serve as a basis for establishing project cost (30% accuracy) in order to intercompare competing designs for a PSNS not only on the basis of technical feasibility and technical merit but also on the basis of projected total cost. The accelerator design considered here is based on the objective of a pulsed neutron source obtained by means of a pulsed proton beam with average beam power of 5 MW, in {approx} 1 {mu}sec pulses, operating at a repetition rate of 60 Hz. Two target stations are incorporated in the basic facility: one for operation at 10 Hz for long-wavelength instruments, and one operating at 50 Hz for instruments utilizing thermal neutrons. The design approach for the proton accelerator is to use a low energy linear accelerator (at 0.6 GeV), operating at 60 Hz, in tandem with two fast cycling booster synchrotrons (at 3.6 GeV), operating at 30 Hz. It is assumed here that considerations of cost and overall system reliability may favor the present design approach over the alternative approach pursued elsewhere, whereby use is made of a high energy linear accelerator in conjunction with a dc accumulation ring. With the knowledge that this alternative design is under active development, it was deliberately decided to favor here the low energy linac-fast cycling booster approach. Clearly, the present design, as developed here, must be carried to the full conceptual design stage in order to facilitate a meaningful technology and cost comparison with alternative designs.

  20. A Project of Boron Neutron Capture Therapy System based on a Proton Linac Neutron Source

    NASA Astrophysics Data System (ADS)

    Kiyanagi, Yoshikai; Asano, Kenji; Arakawa, Akihiro; Fukuchi, Shin; Hiraga, Fujio; Kimura, Kenju; Kobayashi, Hitoshi; Kubota, Michio; Kumada, Hiroaki; Matsumoto, Hiroshi; Matsumoto, Akira; Sakae, Takeji; Saitoh, Kimiaki; Shibata, Tokushi; Yoshioka, Masakazu

    At present, the clinical trials of Boron Neutron Capture Therapy (BNCT) are being performed at research reactor facilities. However, an accelerator based BNCT has a merit that it can be built in a hospital. So, we just launched a development project for the BNCT based on an accelerator in order to establish and to spread the BNCT as an effective therapy in the near future. In the project, a compact proton linac installed in a hospital will be applied as a neutron source, and energy of the proton beam is planned to be less than about 10 MeV to reduce the radioactivity. The BNCT requires epithermal neutron beam with an intensity of around 1x109 (n/cm2/sec) to deliver the therapeutic dose to a deeper region in a body and to complete the irradiation within an hour. From this condition, the current of the proton beam required is estimated to be a few mA on average. Enormous heat deposition in the target is a big issue. We are aiming at total optimization of the accelerator based BNCT from the linac to the irradiation position. Here, the outline of the project is introduced and the moderator design is presented.

  1. LOW VOLTAGE 14 Mev NEUTRON SOURCE

    DOEpatents

    Little, R.N. Jr.; Graves, E.R.

    1959-09-29

    An apparatus yielding high-energy neutrons at the rate of 10/sup 8/ or more per second by the D,T or D,D reactions is described. The deuterium gas filling is ionized by electrons emitted from a filament, and the resulting ions are focused into a beam and accelerated against a fixed target. The apparatus is built in accordance with the relationship V/sub s/ = A--B log pd, where V/sub s/ is the sparking voltage, p the gas pressure, and d the gap length between the high voltage electrodes. Typical parameters to obtain the high neutron yields are 55 to 80 kv, 0.5 to 7.0 ma beam current, 5 to 12 microns D/sub 2/, and a gap length of 1 centimeter.

  2. Compact deuterium-tritium neutron generator using a novel field ionization source

    SciTech Connect

    Ellsworth, J. L. Falabella, S.; Sanchez, J.; Tang, V.; Wang, H.

    2014-11-21

    Active interrogation using neutrons is an effective method for detecting shielded nuclear material. A lightweight, lunch-box-sized, battery-operated neutron source would enable new concepts of operation in the field. We have developed at-scale components for a highly portable, completely self-contained, pulsed Deuterium-Tritium (DT) neutron source producing 14 MeV neutrons with average yields of 10{sup 7} n/s. A gated, field ionization ion source using etched electrodes has been developed that produces pulsed ion currents up to 500 nA. A compact Cockcroft-Walton high voltage source is used to accelerate deuterons into a metal hydride target for neutron production. The results of full scale DT tests using the field ionization source are presented.

  3. Post irradiation examination of the Spallation Neutron Source target vessels

    SciTech Connect

    McClintock, David A; Ferguson, Phillip D; Mansur, Louis K

    2010-01-01

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is an accelerator-based pulsed neutron source that produces high-energy spallation neutrons by bombarding liquid mercury flowing through a stainless steel target vessel. During operation the proton beam and spallation neutrons produce radiation damage in the AISI 316L austenitic stainless steel target vessel and water-cooled shroud. The beam pulses also cause rapid heating of the liquid mercury, which may produce cavitation erosion damage on the inner surface of the target vessel. The cavitation erosion rate is thought to be highly sensitive to beam power and predicted to be the primary life-limiting factor of target vessel. Though mitigation of cavitation erosion and radiation damage to the target vessel will be a critical for successful high-power operation of the SNS facility, the effects of radiation damage and cavitation erosion to target vessels in liquid metal spallation systems are not well known. Therefore preparations are being undertaken to perform post irradiation examination (PIE) of the liquid mercury target vessel and water-cooled shroud after end-of-life occurs. An overview of the planned PIE for the SNS target vessel is presented here, including proposed techniques for specimen acquisition and subsequent material properties characterization.

  4. A neutron resonance capture analysis experimental station at the ISIS spallation source.

    PubMed

    Pietropaolo, Antonino; Gorini, Giuseppe; Festa, Giulia; Reali, Enzo; Grazzi, Francesco; Schooneveld, Erik M

    2010-09-01

    Neutron resonance capture analysis (NRCA) is a nuclear technique that is used to determine the elemental composition of materials and artifacts (e.g., bronze objects) of archaeological interest. NRCA experiments are mostly performed at the GELINA facility in Belgium, a pulsed neutron source operating with an electron linear accelerator. Very intense fluxes of epithermal neutrons are also provided by spallation neutron sources, such as the ISIS spallation neutron source in the United Kingdom. In the present study, the suitability of the Italian Neutron Experimental Station (INES) beam line for NRCA measurements is assessed using a compact (n, γ) resonance detector made of a Yttrium-Aluminum-Perovskite (YAP) scintillation crystal coupled with a silicon photomultiplier (SiPM) readout. The measurements provided a qualitative recognition of the composition of the standard sample, a lower limit for the sensitivity for NRCA for almost-in-traces elements, and an estimation of the relative isotopic concentration in the sample. PMID:20828445

  5. HIGH FLUENCE NEUTRON SOURCE FOR NONDESTRUCTIVE CHARACTERIZATION OF NUCLEAR WASTE

    EPA Science Inventory

    We propose to research the basic plasma physics necessary to develop a high fluence neutron source based on the inertial electrostatically confined (IEC) plasma. An intense neutron source directly addresses the capability to characterize nuclear materials under difficult measurem...

  6. Portable, high intensity isotopic neutron source provides increased experimental accuracy

    NASA Technical Reports Server (NTRS)

    Mohr, W. C.; Stewart, D. C.; Wahlgren, M. A.

    1968-01-01

    Small portable, high intensity isotopic neutron source combines twelve curium-americium beryllium sources. This high intensity of neutrons, with a flux which slowly decreases at a known rate, provides for increased experimental accuracy.

  7. SPALLATION NEUTRON SOURCE RING-DESIGN AND CONSTRUCTION SUMMARY.

    SciTech Connect

    WEI,J.

    2005-05-16

    After six years, the delivery of components for the Spallation Neutron Source (SNS) accumulator ring (AR) and the transport lines was completed in Spring 2005. Designed to deliver 1.5 MW beam power (1.5 x 10{sup 14} protons of 1 GeV kinetic energy at a repetition rate of 60 Hz), stringent measures were implemented in the fabrication, test, and assembly to ensure the quality of the accelerator systems. This paper summarizes the design, R&D, and construction of the ring and transport systems.

  8. Beginnings of remote handling at the RAL Spallation Neutron Source

    SciTech Connect

    Liska, D.J.; Hirst, J.

    1985-01-01

    Expenditure of funds and resources for remote maintenance systems traditionally are delayed until late in an accelerator's development. However, simple remote-surveillance equipment can be included early in facility planning to set the stage for future remote-handling needs and to identify appropriate personnel. Some basic equipment developed in the UK at the Spallation Neutron Source (SNS) that serves this function and that has been used to monitor beam loss during commissioning is described. A photograph of this equipment, positioned over the extractor septum magnet, is shown. This method can serve as a pattern approach to the problem of initiating remote-handling activities in other facilities.

  9. STUDY OF A 10-MW CONTINUOUS SPALLATION NEUTRON SOURCE.

    SciTech Connect

    RUGGIERO,A.G.LUDEWIG,H.SHAPIRO,S.

    2003-05-12

    This paper reports on the feasibility study of a proton Super-Conducting Linac as the driver for an Accelerator-based Continuous Neutron Source (ACNS) [1] to be located at Brookhaven National Laboratory (BNL). The Linac is to be operated in the Continuous Wave (CW) mode to produce an average 10 MW of beam power. The Linac beam energy is taken to be 1.25 GeV. The required average proton beam intensity in exit is then 8 mA.

  10. The new RF sources for accelerators

    SciTech Connect

    Ives, Lawrence; Read, Michael; Ferguson, Patrick; Marsden, David; Collins, George; Jackson, R. H.; Bui, Thuc; Kimura, Takuji; Eisen, Edward

    2012-12-21

    Several new RF sources are being developed for accelerator and collider applications. Assembly is nearing completion of a multiple beam inductive output tube at 352 MHz. An annular beam klystron is being developed to produce 10 MW pulses at 1.3 GHz. The annular beam approach provides significant cost reduction over similar multiple beam devices. Fabrication is underway on a 10 kW, periodic permanent magnet klystron at 2.815 GHz. Permanent magnets eliminate the solenoid and associated power supplies and cooling requirements to reduce operational cost. Investigations are beginning on a novel approach for driving accelerator cavities using pulse shaping to increase coupling efficiency and dramatically reduce RF power requirements.

  11. Development of target system for intense neutron source of p-Li reaction.

    PubMed

    Kamada, So; Takada, Masashi; Suda, Mitsuru; Hamano, Tsuyoshi; Imaseki, Hitoshi; Hoshi, Masaharu; Fujii, Ryo; Nakamura, Masaru; Sato, Hitoshi; Higashimata, Atsushi; Arai, Seiji

    2014-06-01

    A target cooling system was developed for an intense neutron source of p-Li reaction. The system consists of target cooling devices and protection devices for lithium evaporation. A pin-structure cooling device was developed to enhance cooling power. Functional graded material was utilized for the evaporation of lithium. Test experiments were performed by using the neutron exposure accelerator system for biological effect experiments (NASBEE) at the National Institute of Radiological Sciences (NIRS) in Japan. The target system was confirmed to be applicable for accelerator-based boron neutron capture therapy. PMID:24786900

  12. Spallation neutron source and other high intensity froton sources

    SciTech Connect

    Weiren Chou

    2003-02-06

    This lecture is an introduction to the design of a spallation neutron source and other high intensity proton sources. It discusses two different approaches: linac-based and synchrotron-based. The requirements and design concepts of each approach are presented. The advantages and disadvantages are compared. A brief review of existing machines and those under construction and proposed is also given. An R&D program is included in an appendix.

  13. Physics data base for the Beam Plasma Neutron Source (BPNS)

    NASA Astrophysics Data System (ADS)

    Coensgen, F. H.; Casper, T. A.; Correll, D. L.; Damm, C. C.; Futch, A. H.; Molvik, A. W.

    1990-10-01

    A 14-MeV deuterium-tritium (D-T) neutron source for accelerated end-of-life testing of fusion reactor materials has been designed on the basis of a linear two-component collisional plasma system. An intense flux (up to 5 x 10(exp 18)/sq m sec) of 14 MeV neutrons is produced in a fully ionized high-density (n sub e approx. = 3 x 10(exp 21) per cu m) tritium target by transverse injection of 60 MW of neutral beam power. Power deposited in the target is removed by thermal electron conduction to large end chambers, where it is deposited in gaseous plasma collectors. We show in this paper that the major physics issues have now been experimentally demonstrated. These include magnetohydrodynamic (MHD) equilibrium and stability, microstability, startup, fueling, Spitzer electron thermal conductivity, and power deposition in a gaseous plasma collector. However, an integrated system was not demonstrated.

  14. Neutron dose calculation at the maze entrance of medical linear accelerator rooms.

    PubMed

    Falcão, R C; Facure, A; Silva, A X

    2007-01-01

    Currently, teletherapy machines of cobalt and caesium are being replaced by linear accelerators. The maximum photon energy in these machines can vary from 4 to 25 MeV, and one of the great advantages of these equipments is that they do not have a radioactive source incorporated. High-energy (E > 10 MV) medical linear accelerators offer several physical advantages over lower energy ones: the skin dose is lower, the beam is more penetrating, and the scattered dose to tissues outside the target volume is smaller. Nevertheless, the contamination of undesirable neutrons in the therapeutic beam, generated by the high-energy photons, has become an additional problem as long as patient protection and occupational doses are concerned. The treatment room walls are shielded to attenuate the primary and secondary X-ray fluence, and this shielding is generally adequate to attenuate the neutrons. However, these neutrons are scattered through the treatment room maze and may result in a radiological problem at the door entrance, a high occupancy area in a radiotherapy facility. In this article, we used MCNP Monte Carlo simulation to calculate neutron doses in the maze of radiotherapy rooms and we suggest an alternative method to the Kersey semi-empirical model of neutron dose calculation at the entrance of mazes. It was found that this new method fits better measured values found in literature, as well as our Monte Carlo simulated ones. PMID:17005540

  15. Time dependent Monte Carlo calculations of the ORELA (Oak Ridge Electron Linear Accelerator) target neutron spectrum

    SciTech Connect

    Cramer, S.N.; Perey, F.G.

    1990-01-01

    The time dependent spectrum of neutrons in the water-moderated Oak Ridge Electron Linear Accelerator (ORELA) target has been calculated using a modified version of the MORSE multi-group Monte Carlo code with an analytic hydrogen scattering model. Distributions of effective neutron distance traversed in the target are estimated with a time and energy dependent algorithm from the leakage normal to the target face. These data are used in the resonance shaped analyses of time-of-flight cross section measurements to account for the experimental resolution function. The 20 MeV--10 eV energy range is adequately represented in the MORSE code by the 174 group VITAMIN-E cross section library with a P{sub 5} expansion. An approximate representation of the ORELA positron source facility, recently installed near the target, has been included in the calculations to determine any perturbations the positron source might create in the computed neutron distributions from the target. A series of coupled Monte Carlo calculations was performed from the target to the positron source and back to the target using a next-event estimation surface source for each step. The principal effect of the positron source was found to be an increase in the distance for the lower energy neutron spectra, producing no real change in the distributions where the ORELA source is utilized for experiments. Different configurations for the target were investigated in order to simulate the placement of a shadow bar in the neutron beam. These beam configurations included neutrons escaping from : (1) the central tantalum plates only, (2) the entire target with the tantalum plates blocked out, and (3) only a small area from the water. Comparisons of the current data with previous calculations having a less detailed model of the tantalum plates have been satisfactory. 10 refs.

  16. INJECTION CHOICE FOR SPALLATION NEUTRON SOURCE RING.

    SciTech Connect

    WEI,J.; BEEBE-WANG,J.; BLASKIEWICZ,M.; BRODOWSKI,J.; FEDOTOV,A.; GARDNER,C.; LEE,Y.Y.; RAPARIA,D.; DANILOV,V.; HOLMES,J.; PRIOR,C.; REES,G.; MACHIDA,S.

    2001-06-18

    Injection is key in the low-loss design of high-intensity proton facilities like the Spallation Neutron Source (SNS). During the design of both the accumulator and the rapid-cycling-synchrotron version of the SNS, extensive comparison has been made to select injection scenarios that satisfy SNS's low-loss design criteria. This paper presents issues and considerations pertaining to the final choice of the SNS injection systems.

  17. COHERENT at the Spallation Neutron Source

    NASA Astrophysics Data System (ADS)

    Scholberg, Kate; Coherent Collaboration

    2016-03-01

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, Tennessee, provides an intense isotropic flux of neutrinos in the few tens-of-MeV range, with a sharply-pulsed timing structure which is beneficial for background rejection. This talk will describe aspects of COHERENT, the experimental program underway to measure CEvNS (Coherent Elastic Neutrino-Nucleus Scattering) using low-energy nuclear recoil detectors.

  18. Accelerator Sources for THz science: A Review

    SciTech Connect

    Neil, George R.

    2013-07-10

    Free Electron Lasers have been around since 1977 providing not only a test bed for the physics of FELs and electron/photon interactions but as a workhorse of scientific research. More than 30 FELs are presently operating around the world spanning a wavelength range from the millimeter region to the hard x-ray using direct current and rf linear accelerators or storage rings as electron sources. The characteristics that have driven the development of these sources are the desire for high peak and average power, high micropulse energies, wavelength tunability, timing flexibility, and wavelengths that are unavailable from more conventional laser sources. Operation of FELs in the far infrared to terahertz regime poses special challenges which have been and are being addressed at a number of facilities around the world. This paper will review a number of former and existing FELs operating in this regime and discuss future efforts. Broadband collective radiation from relativistic electrons also plays a significant role in the production of FIR/THz radiation and several groups are taking advantage of this source for users. Applications for use of the radiation have evolved from simple imaging to complex pump probe tests of insulator/metal transitions and energy flow in organic molecules. We will discuss the technologies for generating the IR/FIR/THz radiation and cover some of the unique applications of such sources.

  19. A review of ion sources for medical accelerators (invited)

    SciTech Connect

    Muramatsu, M.; Kitagawa, A.

    2012-02-15

    accelerators are under development for the boron neutron capture therapy. This treatment is conventionally demonstrated by a nuclear reactor, but it is strongly expected to replace the reactor by the accelerator. We report status of ion source for medical application and such scope for further developments.

  20. A review of ion sources for medical accelerators (invited).

    PubMed

    Muramatsu, M; Kitagawa, A

    2012-02-01

    under development for the boron neutron capture therapy. This treatment is conventionally demonstrated by a nuclear reactor, but it is strongly expected to replace the reactor by the accelerator. We report status of ion source for medical application and such scope for further developments. PMID:22380341

  1. The advanced neutron source reactor: An overview

    SciTech Connect

    West, C.D.

    1990-01-01

    The Advanced Neutron Source (ANS) will be a new user facility for all kinds of neutron research, including neutron scattering, materials testing, materials analysis, isotope production and nuclear physics experiments. The centerpiece of the facility is to be the world's highest flux beam reactor. There will be beams of hot, cold and thermal neutrons for more than 40 simultaneous scattering and nuclear physics experiments. In addition, there will be irradiation positions and rabbit tubes for in-pile experiments, testing and isotopes production (including transuranium isotopes). To reduce technical risks and to minimize safety issues, the reactor design is based on technology already employed in existing research reactors. The fuel elements are annular assemblies of aluminum clad involute fuel plates, similar to the design of the High Flux Isotope Reactor (HFIR) at Oak Ridge and the Institut Laue-Langevin (ILL) Reactor in Grenoble. As is common with many other research reactors, the core is cooled, moderated and reflected by heavy water. The preferred fuel is U{sub 3}Si{sub 2} - a high-density fuel form developed by Argonne National Laboratory and Babcock and Wilcox that has been extensively tested in reactors in the United States, Europe and Japan. 7 figs., 2 tabs.

  2. Advanced Neutron Sources: Plant Design Requirements

    SciTech Connect

    Not Available

    1990-07-01

    The Advanced Neutron Source (ANS) is a new, world class facility for research using hot, thermal, cold, and ultra-cold neutrons. At the heart of the facility is a 350-MW{sub th}, heavy water cooled and moderated reactor. The reactor is housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides fans out into a large guide hall, housing about 30 neutron research stations. Office, laboratory, and shop facilities are included to provide a complete users facility. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory at the end of the decade. This Plant Design Requirements document defines the plant-level requirements for the design, construction, and operation of the ANS. This document also defines and provides input to the individual System Design Description (SDD) documents. Together, this Plant Design Requirements document and the set of SDD documents will define and control the baseline configuration of the ANS.

  3. Advanced Neutron Source: Plant Design Requirements

    SciTech Connect

    Not Available

    1990-07-01

    The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the set of SDD documents will define and control the baseline configuration of ANS.

  4. Multileaf shielding design against neutrons produced by medical linear accelerators.

    PubMed

    Rebello, W F; Silva, A X; Facure, A

    2008-01-01

    This work aims at presenting a study using Monte Carlo simulation of a Multileaf Shielding (MLS) System designed to be used for the protection of patients who undergo radiotherapy treatment, against undesired exposure to neutrons produced in the components of the medical linear accelerator heads. The choice of radiotherapy equipment as the subject of study fell on the Varian Clinac 2,100/2,300 with MLC-120 operating at 18 MeV. The general purpose Monte Carlo N-Particle radiation transport code, MCNP5, was used in the computer simulation in order to determine the ambient dose equivalent, H (10), on several points on the patient's plane, with the equipment operation with and without the MLS. The results of the simulations showed a significant neutron dose reduction after the inclusion of the proposed shielding. PMID:17569690

  5. A Long-Pulse Spallation Source at Los Alamos: Facility description and preliminary neutronic performance for cold neutrons

    SciTech Connect

    Russell, G.J.; Weinacht, D.J.; Pitcher, E.J.; Ferguson, P.D.

    1998-03-01

    The Los Alamos National Laboratory has discussed installing a new 1-MW spallation neutron target station in an existing building at the end of its 800-MeV proton linear accelerator. Because the accelerator provides pulses of protons each about 1 msec in duration, the new source would be a Long Pulse Spallation Source (LPSS). The facility would employ vertical extraction of moderators and reflectors, and horizontal extraction of the spallation target. An LPSS uses coupled moderators rather than decoupled ones. There are potential gains of about a factor of 6 to 7 in the time-averaged neutron brightness for cold-neutron production from a coupled liquid H{sub 2} moderator compared to a decoupled one. However, these gains come at the expense of putting ``tails`` on the neutron pulses. The particulars of the neutron pulses from a moderator (e.g., energy-dependent rise times, peak intensities, pulse widths, and decay constant(s) of the tails) are crucial parameters for designing instruments and estimating their performance at an LPSS. Tungsten is the reference target material. Inconel 718 is the reference target canister and proton beam window material, with Al-6061 being the choice for the liquid H{sub 2} moderator canister and vacuum container. A 1-MW LPSS would have world-class neutronic performance. The authors describe the proposed Los Alamos LPSS facility, and show that, for cold neutrons, the calculated time-averaged neutronic performance of a liquid H{sub 2} moderator at the 1-MW LPSS is equivalent to about 1/4th the calculated neutronic performance of the best liquid D{sub 2} moderator at the Institute Laue-Langevin reactor. They show that the time-averaged moderator neutronic brightness increases as the size of the moderator gets smaller.

  6. Radiation effects in materials for accelerator-driven neutron technologies. Revision

    SciTech Connect

    Wechsler, M.S.; Lin, C.; Sommer, W.F.

    1997-04-01

    Accelerator-driven neutron technologies use spallation neutron sources (SNS`s) in which high-energy protons bombard a heavy-element target and spallation neutrons are produced. The materials exposed to the most damaging radiation environments in an SNS are those in the path of the incident proton beam. This includes target and window materials. These materials will experience damage from the incident protons and the spallation neutrons. In addition, some materials will be damaged by the spallation neutrons alone. The principal materials of interest for SNS`s are discussed elsewhere. The target should consist of one or more heavy elements, so as to increase the number of neutrons produced per incident proton. A liquid metal target (e.g., Pb, Bi, Pb-Bi, Pb-Mg, and Hg) has the advantage of eliminating the effects of radiation damage on the target material itself, but concerns over corrosion problems and the influence of transmutants remain. The major solid targets in operating SNS`s and under consideration for the 1-5 MW SNS`s are W, U, and Pb. Tungsten is the target material at LANSCE, and is the projected target material for an upgraded LANSCE target that is presently being designed. It is also the projected target material for the tritium producing SNS under design at LANL. In this paper, the authors present the results of spallation radiation damage calculations (displacement and He production) for tungsten.

  7. Spallation Neutron Source Operating Experience and Outlook for Upgrades

    NASA Astrophysics Data System (ADS)

    Henderson, Stuart

    2010-03-01

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is a MW-class accelerator-driven pulsed neutron source. The SNS began formal operations in October 2006. Since then, the beam power has been increased to 1 MW, the number of operating hours per year has increased to nearly 5000, the availability has increased to 85%, and the number of operating neutron scattering instruments has increased to 13. Plans are in place to increase the beam power and availability to their design values of 1.4 MW and 90% over the next two years, and to continue the build-out of instruments to 16 by 2012. Two upgrade projects are in the planning stages. In the first, the beam power of the SNS is increased to at least 2 MW by raising the beam energy from 1.0 to 1.3 GeV and the beam current by 60%. In the second, a Second Target Station is constructed, and is powered by sharing beam pulses with the first target station. The operating experience will be described, as will the challenges that have been met along the path toward 1 MW beam power. The strategy for upgrades will also be presented.

  8. High-Power Linac for the Spallation Neutron Source

    NASA Astrophysics Data System (ADS)

    Rej, D. J.

    2002-04-01

    The Spallation Neutron Source (SNS) will be the world’s most intense source of neutrons for fundamental science and industrial applications. Design and construction of this facility, located at Oak Ridge, is a joint venture between six DOE laboratories. Construction began in 1999 and is currently ahead of the scheduled 2006 completion date. Injecting a high-power, pulsed proton beam into a mercury target produces neutrons. In this talk, we review the physics requirements, design, and status of the construction of the 1-GeV, 1.4-MW average power RF linac for SNS. The accelerator consists of a drift tube linac (DTL), a coupled-cavity linac (CCL), and a superconducting rf (SRF) linac. The phase and quadrupole settings are set to avoid structure and parametric resonances, with coherent resonances posing minimal risk for emittance growth. The DTL is 37 m long and accelerates the ions to 87 MeV. The CCL is 55 m long and accelerates the ions to 186 MeV. The rf structure design and stability for both the DTL and CCL have been validated with scale models. The SRF linac has a modular design to accelerate ions to 1000 MeV, with a straightforward upgrade to 1.3 GeV at a later date. 3D particle-in-cell simulations of beam dynamics are performed to validate performance. The accelerator utilizes 93 MW of pulsed power operating continuously at 60-Hz with an 8factor. Approximately one hundred 402.5 or 805-MHz klystrons, with outputs between 0.55 and 5 MW, are used. The klystrons are powered by a novel converter-modulator that takes advantage of recent advances in IGBT switch plate assemblies and low-loss material cores for boost transformer. Beam diagnostics include position, phase, profile, and current monitors. They are designed to enable accurate beam steering and matching, and to minimize beam loss that would lead to activation and prevent hands-on maintenance.

  9. The Advanced Neutron Source liquid deuterium cold source

    SciTech Connect

    Lucas, A.T.

    1995-08-01

    The Advanced Neutron Source will employ two cold sources to moderate neutrons to low energy (<10 meV). The cold neutrons produced are then passed through beam guides to various experiment stations. Each cold source moderator is a sphere of 410-mm internal diameter. The moderator material is liquid deuterium flowing at a rate of 1 kg/s and maintained at subcooled temperatures at all points of the circuit, to prevent boiling. Nuclear beat deposited within the liquid deuterium and its containment structure totals more than 30 kW. All of this heat is removed by the liquid deuterium, which raises its temperature by 5 K. The liquid prime mover is a cryogenic circulator that is situated in the return leg of the flow loop. This arrangement minimizes the heat added to the liquid between the heat exchanger and the moderator vessel, allowing the moderator to be operated at the minimum practical temperature. This report describes the latest thinking at the time of project termination. It also includes the status of various systems at that time and outlines anticipated directions in which the design would have progressed. In this regard, some detail differences between this report and official design documents reflect ideas that were not approved at the time of closure but are considered noteworthy.

  10. Radiation dose measurements and Monte Carlo calculations for neutron and photon reactions in a human head phantom for accelerator-based boron neutron capture therapy

    NASA Astrophysics Data System (ADS)

    Kim, Don-Soo

    Dose measurements and radiation transport calculations were investigated for the interactions within the human brain of fast neutrons, slow neutrons, thermal neutrons, and photons associated with accelerator-based boron neutron capture therapy (ABNCT). To estimate the overall dose to the human brain, it is necessary to distinguish the doses from the different radiation sources. Using organic scintillators, human head phantom and detector assemblies were designed, constructed, and tested to determine the most appropriate dose estimation system to discriminate dose due to the different radiation sources that will ultimately be incorporated into a human head phantom to be used for dose measurements in ABNCT. Monoenergetic and continuous energy neutrons were generated via the 7Li(p,n)7Be reaction in a metallic lithium target near the reaction threshold using the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell. A human head phantom was built to measure and to distinguish the doses which result from proton recoils induced by fast neutrons, alpha particles and recoil lithium nuclei from the 10B(n,alpha)7Li reaction, and photons generated in the 7Li accelerator target as well as those generated inside the head phantom through various nuclear reactions at the same time during neutron irradiation procedures. The phantom consists of two main parts to estimate dose to tumor and dose to healthy tissue as well: a 3.22 cm3 boron loaded plastic scintillator which simulates a boron containing tumor inside the brain and a 2664 cm3 cylindrical liquid scintillator which represents the surrounding healthy tissue in the head. The Monte Carlo code MCNPX(TM) was used for the simulation of radiation transport due to neutrons and photons and extended to investigate the effects of neutrons and other radiation on the brain at various depths.

  11. Intense steady state neutron source. The CNR reactor

    SciTech Connect

    Difilippo, F.C.; Moon, R.M.; Gambill, W.R.; Moon, R.M.; Primm, R.T. III; West, C.D.

    1986-01-01

    The Center for Neutron Research (CNR) has been proposed in response to the needs - neutron flux, spectrum, and experimental facilities - that have been identified through workshops, studies, and discussions by the neutron-scattering, isotope, and materials irradiation research communities. The CNR is a major new experimental facility consisting of a reactor-based steady state neutron source of unprecedented flux, together with extensive facilities and instruments for neutron scattering, isotope production, materials irradiation, and other areas of research.

  12. Neutron diffractometers for structural biology at spallation neutron sources

    SciTech Connect

    Schoenborn, B.P.; Pitcher, E.

    1994-12-31

    Spallation neutron sources are ideal for diffraction studies of proteins and oriented molecular complexes. With spoliation neutrons and their time dependent wavelength structure, it is easy to electronically select data with an optimal wavelength bandwidth and cover the whole Laue spectrum as time (wavelength) resolved snapshots. This optimized data quality with best peak-to-background ratios and provides adequate spatial and energy resolution to eliminate peak overlaps. The application of this concept will use choppers to select the desired Laue wavelength spectrum and employ focusing optics and large cylindrical {sup 3}He detectors to optimize data collection rates. Such a diffractometer will cover a Laue wavelength range from 1 to 5{Angstrom} with a flight path length of 10m and an energy resolution of 0.25{Angstrom}. Moderator concepts for maximal flux distribution within this energy range will be discussed using calculated flux profiles. Since the energy resolution required for such timed data collection in this super Laue techniques is not very high, the use of a linac only (LAMPF) spoliation target is an exciting possibility with an order of magnitude increase in flux.

  13. The Linac Cooherent Light Source (LCLS) Accelerator

    SciTech Connect

    Wu, Juhao; Emma, P.; /SLAC

    2007-03-21

    The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. Such an FEL requires a high energy, high brightness electron beam to drive the FEL instability to saturation. When fed by an RF-photocathode gun, and modified to include two bunch compressor chicanes, the SLAC linac will provide such a high quality beam at 14 GeV and 1-{micro}m normalized emittance. In this paper, we report on recent linac studies, including beam stability and tolerances, longitudinal and transverse feedback systems, conventional and time-resolved diagnostics, and beam collimation systems. Construction and installation of the injector through first bunch compressor will be completed by December 2006, and electron commissioning is scheduled to begin in January of 2007.

  14. New sources and instrumentation for neutrons in biology

    PubMed Central

    Teixeira, S.C.M.; Ankner, J.; Bellissent-Funel, M.C.; Bewley, R.; Blakeley, M.P.; Coates, L.; Dahint, R.; Dalgliesh, R.; Dencher, N.; Dhont, J.; Fischer, P.; Forsyth, V.T.; Fragneto, G.; Frick, B.; Geue, T.; Gilles, R.; Gutberlet, T.; Haertlein, M.; Hauß, T.; Häußler, W.; Heller, W.T.; Herwig, K.; Holderer, O.; Juranyi, F.; Kampmann, R.; Knott, R.; Kohlbrecher, J.; Kreuger, S.; Langan, P.; Lechner, R.; Lynn, G.; Majkrzak, C.; May, R.; Meilleur, F.; Mo, Y.; Mortensen, K.; Myles, D.A.A.; Natali, F.; Neylon, C.; Niimura, N.; Ollivier, J.; Ostermann, A.; Peters, J.; Pieper, J.; Rühm, A.; Schwahn, D.; Shibata, K.; Soper, A.K.; Straessle, T.; Suzuki, U.-i.; Tanaka, I.; Tehei, M.; Timmins, P.; Torikai, N.; Unruh, T.; Urban, V.; Vavrin, R.; Weiss, K.; Zaccai, G.

    2008-01-01

    Neutron radiation offers significant advantages for the study of biological molecular structure and dynamics. A broad and significant effort towards instrumental and methodological development to facilitate biology experiments at neutron sources worldwide is reviewed. PMID:19132140

  15. Dual-mode operation of a neutron source, a concept

    NASA Technical Reports Server (NTRS)

    Givens, W. W.; Mills, W. R., Jr.

    1969-01-01

    Pulsed neutron source operates in conjunction with a photomultiplier tube coupled to a gamma ray scintillation crystal. This allows measurements of gamma radiation from both inelastic scattering and thermal neutron capture in a single experiment.

  16. Neutronic and Physical Characteristics of an Accelerator Driven System with a Lead-208 Coolant

    SciTech Connect

    Khorasanov, Georgy L.; Ivonov, Anatoly P.; Blokhin, Anatoly I.

    2006-07-01

    In the paper a possibility of using a lead isotope, pure Pb-208, as a coolant for a subcritical core of 80 MW thermal capacity of the PDS-XADS type facility is considered. Calculations of neutronic characteristics were performed using Monte Carlo technique. The following initial data were chosen: an annular core with a target, as a neutron source, at its centre; the core coolant -- Pb-208 (100%); a fuel -- a mix of mono nitrides of depleted uranium and power plutonium with a small share of neptunium and americium; the target coolant -- a modified lead and bismuth eutectic, Pb-208(80%)-Bi(20%); proton beam energy -- 600 MeV; effective multiplication factor of the core under operation -- K{sub eff} = 0.97; thermal capacity of the core -- N = 80 MW. From calculations performed it follows that in using Pb-208 as the core coolant the necessary intensity of the external source of neutrons to deliver 80 MW thermal capacity is equal to S = 2.29-10{sup 17} n/s that corresponds to proton beam current I{sub p} = 2.8 mA and beam capacity P{sub p} 1.68 MW. In using natural lead instead of Pb-208 as the core coolant, effective multiplication factor of the core in normal operating regime falls down to the value equal to K{sub eff} = 0.95. In these conditions multiplication of external neutrons in the core and thermal capacity of the subcritical core are below nominal by 1.55 times. For achievement the rated core power N=80 MW it is required on {approx}20-30% to increase the fuel loading and volume of the core, or by 1.55 times to increase intensity of the external source of neutrons. In the last case, the required parameters of the neutron source and of the corresponding proton beam are following: intensity of the neutron source S = 3.55 10{sup 17} n/s., beam current I{sub p} = 4.32 mA, beam capacity P{sub p} 2.59 MW. To exploit the accelerator with the reduced proton beam current it will be required about 56 tons of Pb-208, as a minimum, for the core coolant. Charges for its

  17. The possible use of a spallation neutron source for neutron capture therapy with epithermal neutrons

    SciTech Connect

    Grusell, E.; Conde, H.; Larsson, B.; Roennqvist, T.; Sornsuntisook, O.; Crawford, J.; Reist, H.; Dahl, B.; Sjoestrand, N.G.; Russel, G. . Dept. of Radiation Sciences; Paul Scherrer Inst. , Villigen; Chalmers Univ. of Tech., Goeteborg . Dept. of Reactor Physics; Los Alamos National Lab., NM )

    1989-01-01

    Spallation is induced in a heavy material by 72 MeV protons. The hereby produced neutrons with essentially an evaporation spectrum with a peak energy of less than 2 MeV are moderated in two steps, first in iron, and then in carbon. Results from neutron fluence measurements in a perspex phantom placed close to the moderator are presented. Monte Carlo calculations of neutron fluence in a water phantom are also presented under some chosen configurations of spallation source and moderator. The calculations and measurements show a good agreement and also show that useful thermal neutron fluences are attainable in the depth of the brain, at proton currents of less than 0.5 mA. 3 refs., 5 figs., 4 tabs.

  18. Accelerator requirements for fast-neutron interrogation of luggage and cargo

    SciTech Connect

    Micklich, B.J.; Fink, C.L.; Yule, T.J.

    1995-05-01

    Several different fast-neutron based techniques are being studied for the detection of contraband substances in luggage and cargo containers. The present work discusses the accelerator requirements for fast-neutron transmission spectroscopy (FNTS), pulsed fast-neutron analysis (PFNA), and 14-MeV neutron interrogation. These requirements are based on the results of Monte-Carlo simulations of neutron or gamma detection rates. Accelerator requirements are driven by count-rate considerations, spatial resolution and acceptable uncertainties in elemental compositions. The authors have limited their analyses to luggage inspection with FNTS and to cargo inspection with PFNA or 14-MeV neutron interrogation.

  19. Status of the intense pulsed neutron source

    SciTech Connect

    Brown, B.S.; Carpenter, J.M.; Crawford, R.K.; Rauchas, A.V.; Schulke, A.W.; Worlton, T.G.

    1988-01-01

    IPNS is not unique in having concerns about the level of funding, and the future looks good despite these concerns. This report details the progress made at IPNS during the last two years. Other papers in these proceedings discuss in detail the status of the enriched uranium Booster target, the two instruments that are under construction, GLAD and POSY II, and a proposal for research on an Advanced Pulsed Neutron Source (ASPUN) that has been submitted to the Department of Energy (DOE). Further details on IPNS are available in the IPNS Progress Report 1987--1988, available by writing the IPNS Division Office. 9 refs., 3 tabs.

  20. Spallation neutron source beam loss monitor system

    NASA Astrophysics Data System (ADS)

    Gassner, D.; Witkover, R.; Cameron, P.; Power, J.

    2000-11-01

    The Spallation Neutron Source facility to be built at ORNL is designed to accumulate 2×1014 protons at 1.0 GeV and deliver them to the experimental target in one bunch at 60 Hz. To achieve this goal and protect the machine from excessive radiation activation, an uncontrolled loss criteria of 1 part in 104 (1 W/m) has been specified. Measured losses will be conditioned to provide machine tuning data, a beam abort trigger, and logging of loss history. The design of the distributed loss monitor system utilizing argon-filled glass ionization chambers and scintillator-photomultipliers will be presented.

  1. Neutron star binaries, pulsars and burst sources

    NASA Technical Reports Server (NTRS)

    Lamb, F. K.

    1981-01-01

    Unresolved issues involving neutron star binaries, pulsars, and burst sources are described. Attention is drawn to the types of observations most likely to resolve them. Many of these observations are likely to be carried out during the next decade by one or more missions that have been approved or proposed. Flux measurements with an imaging detector and broad-band spectroscopic studies in the energy range 30-150 keV are discussed. The need for soft X-ray and X-ray observations with an instrument which has arcminute angular resolution and an effective area substantially greater than of ROSAT or EXOSAT is also discussed.

  2. Bright Laser-Driven Neutron Source Based on the Relativistic Transparency of Solids

    NASA Astrophysics Data System (ADS)

    Roth, M.; Jung, D.; Falk, K.; Guler, N.; Deppert, O.; Devlin, M.; Favalli, A.; Fernandez, J.; Gautier, D.; Geissel, M.; Haight, R.; Hamilton, C. E.; Hegelich, B. M.; Johnson, R. P.; Merrill, F.; Schaumann, G.; Schoenberg, K.; Schollmeier, M.; Shimada, T.; Taddeucci, T.; Tybo, J. L.; Wagner, F.; Wender, S. A.; Wilde, C. H.; Wurden, G. A.

    2013-01-01

    Neutrons are unique particles to probe samples in many fields of research ranging from biology to material sciences to engineering and security applications. Access to bright, pulsed sources is currently limited to large accelerator facilities and there has been a growing need for compact sources over the recent years. Short pulse laser driven neutron sources could be a compact and relatively cheap way to produce neutrons with energies in excess of 10 MeV. For more than a decade experiments have tried to obtain neutron numbers sufficient for applications. Our recent experiments demonstrated an ion acceleration mechanism based on the concept of relativistic transparency. Using this new mechanism, we produced an intense beam of high energy (up to 170 MeV) deuterons directed into a Be converter to produce a forward peaked neutron flux with a record yield, on the order of 1010n/sr. We present results comparing the two acceleration mechanisms and the first short pulse laser generated neutron radiograph.

  3. Bright laser-driven neutron source based on the relativistic transparency of solids.

    PubMed

    Roth, M; Jung, D; Falk, K; Guler, N; Deppert, O; Devlin, M; Favalli, A; Fernandez, J; Gautier, D; Geissel, M; Haight, R; Hamilton, C E; Hegelich, B M; Johnson, R P; Merrill, F; Schaumann, G; Schoenberg, K; Schollmeier, M; Shimada, T; Taddeucci, T; Tybo, J L; Wagner, F; Wender, S A; Wilde, C H; Wurden, G A

    2013-01-25

    Neutrons are unique particles to probe samples in many fields of research ranging from biology to material sciences to engineering and security applications. Access to bright, pulsed sources is currently limited to large accelerator facilities and there has been a growing need for compact sources over the recent years. Short pulse laser driven neutron sources could be a compact and relatively cheap way to produce neutrons with energies in excess of 10 MeV. For more than a decade experiments have tried to obtain neutron numbers sufficient for applications. Our recent experiments demonstrated an ion acceleration mechanism based on the concept of relativistic transparency. Using this new mechanism, we produced an intense beam of high energy (up to 170 MeV) deuterons directed into a Be converter to produce a forward peaked neutron flux with a record yield, on the order of 10(10)  n/sr. We present results comparing the two acceleration mechanisms and the first short pulse laser generated neutron radiograph. PMID:25166169

  4. LENS: A New Pulsed Neutron Source for Research and Education

    PubMed Central

    Leuschner, M.; Baxter, D. V.; Cameron, J. M.; Derenchuk, V.; Lavelle, C.; Lone, A.; Nann, H.; Rinckel, T.; Snow, W. M.

    2005-01-01

    A new pulsed neutron source is under construction at the Indiana University Cyclotron Facility (IUCF). Neutrons are produced via (p,n) reactions by a low-energy proton beam incident on a thin beryllium target. The source is tightly coupled to a cold methane moderator held at a temperature of 20 K or below. The resulting time-averaged cold neutron flux is expected to be comparable to that of the Intense Pulsed Neutron Source (IPNS) facility at Argonne National Laboratory. The initial experimental suite will include instrumentation for small angle neutron scattering (SANS), moderator studies, radiography, and zero-field spin-echo SANS. PMID:27308113

  5. Proceedings of the workshop on ion source issues relevant to a pulsed spallation neutron source: Part 1: Workshop summary

    SciTech Connect

    Schroeder, L.; Leung, K.N.; Alonso, J.

    1994-10-01

    The workshop reviewed the ion-source requirements for high-power accelerator-driven spallation neutron facilities, and the performance of existing ion sources. Proposals for new facilities in the 1- to 5-MW range call for a widely differing set of ion-source requirements. For example, the source peak current requirements vary from 40 mA to 150 mA, while the duty factor ranges from 1% to 9%. Much of the workshop discussion centered on the state-of-the-art of negative hydrogen ion source (H{sup {minus}}) technology and the present experience with Penning and volume sources. In addition, other ion source technologies, for positive ions or CW applications were reviewed. Some of these sources have been operational at existing accelerator complexes and some are in the source-development stage on test stands.

  6. Carbon Nanotube Based Deuterium Ion Source for Improved Neutron Generators

    SciTech Connect

    Fink, R. L.; Jiang, N.; Thuesen, L.; Leung, K. N.; Antolak, A. J.

    2009-03-10

    Field ionization uses high electric fields to cause the ionization and emission of ions from the surface of a sharp electrode. We are developing a novel field ionization neutron generator using carbon nanotubes (CNT) to produce the deuterium ion current. The generator consists of three major components: a deuterium ion source made of carbon nanotubes, a smooth negatively-biased target electrode, and a secondary electron suppression system. When a negative high voltage is applied on the target electrode, a high gradient electric field is formed at the tips of the carbon nanotubes. This field is sufficiently strong to create deuterium (D) ions at or near the nanotubes which are accelerated to the target causing D-D reactions to occur and the production of neutrons. A cross magnetic field is used to suppress secondary emission electrons generated on the target surface. We have demonstrated field ionization currents of 70 nA (1 {mu}A/cm{sup 2}) at hydrogen gas pressure of 10 mTorr. We have found that the current scales proportionally with CNT area and also with the gas pressure in the range of 1 mTorr to 10 mTorr. We have demonstrated pulse cut-off times as short as 2 {mu}sec. Finally, we have shown the feasibility of generating neutrons using deuterium gas.

  7. Preliminary energy-filtering neutron imaging with time-of-flight method on PKUNIFTY: A compact accelerator based neutron imaging facility at Peking University

    NASA Astrophysics Data System (ADS)

    Wang, Hu; Zou, Yubin; Wen, Weiwei; Lu, Yuanrong; Guo, Zhiyu

    2016-07-01

    Peking University Neutron Imaging Facility (PKUNIFTY) works on an accelerator-based neutron source with a repetition period of 10 ms and pulse duration of 0.4 ms, which has a rather low Cd ratio. To improve the effective Cd ratio and thus improve the detection capability of the facility, energy-filtering neutron imaging was realized with the intensified CCD camera and time-of-flight (TOF) method. Time structure of the pulsed neutron source was firstly simulated with Geant4, and the simulation result was evaluated with experiment. Both simulation and experiment results indicated that fast neutrons and epithermal neutrons were concentrated in the first 0.8 ms of each pulse period; meanwhile in the period of 0.8-2.0 ms only thermal neutrons existed. Based on this result, neutron images with and without energy filtering were acquired respectively, and it showed that detection capability of PKUNIFTY was improved with setting the exposure interval as 0.8-2.0 ms, especially for materials with strong moderating capability.

  8. Monte Carlo Simulations Of The Response Of Shielded SNM To A Pulsed Neutron Source

    NASA Astrophysics Data System (ADS)

    Seabury, E. H.; Chichester, D. L.

    2011-06-01

    Active neutron interrogation has been used as a technique for the detection and identification of special nuclear material (SNM) for both proposed and field-tested systems. Idaho National Laboratory (INL) has been studying this technique for systems ranging from small systems employing portable electronic neutron generators to larger systems employing linear accelerators as high-energy photon sources for assessment of vehicles and cargo. In order to assess the feasibility of new systems, INL has undertaken a campaign of Monte Carlo simulations of the response of a variety of masses of SNM in multiple shielding configurations to a pulsed neutron source using the MCNPX code, with emphasis on the neutron and photon response of the system as a function of time after the initial neutron pulse. We present here some preliminary results from these calculations.

  9. Dosimetric characterization of the irradiation cavity for accelerator-based in vivo neutron activation analysis.

    PubMed

    Byun, S H; Pejović-Milić, A; McMaster, S; Matysiak, W; Aslam; Liu, Z; Watters, L M; Prestwich, W V; McNeill, F E; Chettle, D R

    2007-03-21

    A neutron irradiation cavity for in vivo activation analysis has been characterized to estimate its dosimetric specifications. The cavity is defined to confine irradiation to the hand and modifies the neutron spectrum produced by a low energy accelerator neutron source to optimize activation per dose. Neutron and gamma-ray dose rates were measured with the microdosimetric technique using a tissue-equivalent proportional counter at the hand irradiation site and inside the hand access hole. For the outside of the cavity, a spherical neutron dose equivalent meter and a Farmer dosemeter were employed instead due to the low intensity of the radiation field. The maximum dose equivalent rate at the outside of the cavity was 2.94 microSv/100 microA min, which is lower by a factor of 1/2260 than the dose rate at the hand irradiation position. The local dose contributions from a hand, an arm and the rest of a body to the effective dose rate were estimated to be 1.73, 0.782 and 2.94 microSv/100 microA min, respectively. For the standard irradiation protocol of the in vivo hand activation, 300 microA min, an effective dose of 16.3 microSv would be delivered. PMID:17455391

  10. Current progress and future prospects of the VITA based neutron source.

    PubMed

    Aleynik, V; Bashkirtsev, A; Kanygin, V; Kasatov, D; Kuznetsov, A; Makarov, A; Schudlo, I; Sorokin, I; Taskaev, S; Tiunov, M

    2014-06-01

    At the BINP, a pilot accelerator based epithermal neutron source is now in use. Most recent investigations on the facility are related with studying the dark current, X-ray radiation measuring, optimization of H(-)-beam injection and new gas stripping target calibrating. The results of these studies, ways of providing stability to the accelerator are presented and discussed, as well as the ways of creating the therapeutic beam and strategies of applying the facility for clinical use. PMID:24369890

  11. Neutronics analysis of three beam-filter assemblies for an accelerator-based BNCT facility

    SciTech Connect

    Bleuel, D.L.; Costes, S.V.; Donahue, R.J.; Ludewigt, B.A.

    1997-08-01

    Three moderator materials, AlF{sub 3}/Al, D{sub 2}O and LiF, have been analyzed for clinical usefulness using the reaction {sup 7}Li(p,n) as an accelerator driven neutron source. Proton energies between 2.1 MeV and 2.6 MeV have been investigated. Radiation transport in the reflector/moderator assembly is simulated using the MCNP program. Depth-dose distributions in a head phanton are calculated with the BNCT-RTPE patient treatment planning program from INEEL using the MCNP generated neutron and photon spectra as the subsequent source. Clinical efficacy is compared using the current BMRR protocol for all designs. Depth-dose distributions are compared for a fixed normal tissue tolerance dose of 12.5 Gy-Eq. Radiation analyses also include a complete anthropomorphic phantom. Results of organ and whole body dose components are presented for several designs. Results indicate that high quality accelerator beams may produce clinically favorable treatments to deep-seated tumors when compared to the BMRR beam. Also discussed are problems identified in comparing accelerator and reactor based designs using in-air figures of merit as well as some results of spectrum-averaged RBE`s.

  12. A compact ion source and accelerator based on a piezoelectric driver

    SciTech Connect

    Norgard, P.; Kovaleski, S. D.; VanGordon, J. A.; Baxter, E. A.; Gall, B. B.; Kwon, Jae Wan; Kim, Baek Hyun; Dale, G. E.

    2013-04-19

    Compact ion sources and accelerators using piezoelectric devices for the production of energetic ion beams are being evaluated. A coupled source-accelerator is being tested as a neutron source to be incorporated into oil-well logging diagnostics. Two different ion sources are being investigated, including a piezoelectric transformer-based plasma source and a silicon-based field ion source. The piezoelectric transformer plasma ion source uses a cylindrical, resonantly driven piezoelectric crystal to produce high voltage inside a confined volume filled with low pressure deuterium gas. The plasma generated in the confined chamber is ejected through a small aperture into an evacuated drift region. The silicon field ion source uses localized electric field enhancement produced by an array of sharp emitters etched into a silicon blank to produce ions through field desorption ionization. A second piezoelectric device of a different design is used to generate an accelerating potential on the order of 130 kV; this potential is applied to a deuterated target plate positioned perpendicular to the ion stream produced by either plasma source. This paper discusses the results obtained by the individual components as they relate to the final neutron source.

  13. CMFD acceleration of spatial domain-decomposed neutron transport problems

    SciTech Connect

    Kelley, B. W.; Larsen, E. W.

    2012-07-01

    A significant limitation to parallelizing the solution of neutron transport problems is the need for sweeps across the entirety of the problem domain. Angular domain decomposition is common practice, as the equations for each direction are independent aside from their shared scattering/fission source. Accordingly, spatial domain decomposition does not naturally arise in the transport equations and is therefore less frequent in practice. In this paper, we show that a neutron transport domain can be straightforwardly divided into independent, parallelizable sweep regions, globally linked with the standard CMFD method, with an additional update equation. We verify, theoretically (via Fourier analysis) and computationally, that the convergence properties of this method are stable and nominally as rapid as standard CMFD. (authors)

  14. Radiation effects in materials for accelerator-driven neutron technologies

    SciTech Connect

    Wechsler, M.S.; Lin, C.; Sommer, W.F.; Daemen, L.L.; Ferguson, P.D.

    1997-03-01

    The materials exposed to the most damaging radiation environments in an SNS (spallation neutron source) are those in the path of the incident proton beam. This includes target and window materials. These materials will experience damage from the incident protons and the spallation neutrons. The major solid targets in operating SNS`s and under consideration for the 1--5 MW SNS`s are W, U, and Pb. Tungsten is the target material at LANSCE, and is the project target material for an upgraded LANSCE target that is presently being designed. It is also the projected target material for the tritium producing SNS under design at LANL. In this paper, the authors present the results of spallation radiation damage calculations (displacement and He production) for tungsten.

  15. Transient particle acceleration in strongly magnetized neutron stars. II - Effects due to a dipole field geometry

    NASA Technical Reports Server (NTRS)

    Fatuzzo, Marco; Melia, Fulvio

    1991-01-01

    Sheared Alfven waves generated by nonradial crustal disturbances above the polar cap of a strongly magnetized neutron star induce an electric field component parallel to B. An attempt is made to determine the manner in which the strong radial dependence of B affects the propagation of these sheared Alfven waves, and whether this MHD process is still an effective particle accelerator. It is found that although the general field equation is quite complicated, a simple wavelike solution can still be obtained under the conditions of interest for which the Alfven phase velocity decouples from the wave equation. The results may be applicable to gamma-ray burst sources.

  16. Pre-conceptual design and preliminary neutronic analysis of the proposed National Spallation Neutron Source (NSNS)

    SciTech Connect

    Johnson, J.O.; Barnes, J.M.; Charlton, L.A.

    1997-03-01

    The Department of Energy (DOE) has initiated a pre-conceptual design study for the National Spallation Neutron Source (NSNS) and given preliminary approval for the proposed facility to be built at Oak Ridge National Laboratory (ORNL). The pre-conceptual design of the NSNS initially consists of an accelerator system capable of delivering a 1 to 2 GeV proton beam with 1 MW of beam power in an approximate 0.5 {micro}s pulse at a 60 Hz frequency onto a single target station. The NSNS will be upgradable to a significantly higher power level with two target stations (a 60 Hz station and a 10 Hz station). There are many possible layouts and designs for the NSNS target stations. This paper gives a brief overview of the proposed NSNS with respect to the target station, as well as the general philosophy adopted for the neutronic design of the NSNS target stations. A reference design is presented, and some preliminary neutronic results for the NSNS are briefly discussed.

  17. Medical Isotope Production Analyses In KIPT Neutron Source Facility

    SciTech Connect

    Talamo, Alberto; Gohar, Yousry

    2016-01-01

    Medical isotope production analyses in Kharkov Institute of Physics and Technology (KIPT) neutron source facility were performed to include the details of the irradiation cassette and the self-shielding effect. An updated detailed model of the facility was used for the analyses. The facility consists of an accelerator-driven system (ADS), which has a subcritical assembly using low-enriched uranium fuel elements with a beryllium-graphite reflector. The beryllium assemblies of the reflector have the same outer geometry as the fuel elements, which permits loading the subcritical assembly with different number of fuel elements without impacting the reflector performance. The subcritical assembly is driven by an external neutron source generated from the interaction of 100-kW electron beam with a tungsten target. The facility construction was completed at the end of 2015, and it is planned to start the operation during the year of 2016. It is the first ADS in the world, which has a coolant system for removing the generated fission power. Argonne National Laboratory has developed the design concept and performed extensive design analyses for the facility including its utilization for the production of different radioactive medical isotopes. 99Mo is the parent isotope of 99mTc, which is the most commonly used medical radioactive isotope. Detailed analyses were performed to define the optimal sample irradiation location and the generated activity, for several radioactive medical isotopes, as a function of the irradiation time.

  18. SU-E-T-543: Measurement of Neutron Activation From Different High Energy Varian Linear Accelerators

    SciTech Connect

    Thatcher, T; Madsen, S; Sudowe, R; Meigooni, A Soleimani

    2015-06-15

    Purpose: Linear accelerators producing photons above 10 MeV may induce photonuclear reactions in high Z components of the accelerator. These liberated neutrons can then activate the structural components of the accelerator and other materials in the beam path through neutron capture reactions. The induced activity within the accelerator may contribute to additional dose to both patients and personnel. This project seeks to determine the total activity and activity per activated isotope following irradiation in different Varian accelerators at energies above 10 MeV. Methods: A Varian 21IX accelerator was used to irradiate a 30 cm × 30 cm × 20 cm solid water phantom with 15 MV x-rays. The phantom was placed at an SSD of 100 cm and at the center of a 20 cm × 20 cm field. Activation induced gamma spectra were acquired over a 5 minute interval after 1 and 15 minutes from completion of the irradiation. All measurements were made using a CANBERRA Falcon 5000 Portable HPGe detector. The majority of measurements were made in scattering geometry with the detector situated at 90° to the incident beam, 30 cm from the side of the phantom and approximately 10 cm from the top. A 5 minute background count was acquired and automatically subtracted from all subsequent measurements. Photon spectra were acquired for both open and MLC fields. Results: Based on spectral signatures, nuclides have been identified and their activities calculated for both open and MLC fields. Preliminary analyses suggest that activities from the activation products in the microcurie range. Conclusion: Activation isotopes have been identified and their relative activities determined. These activities are only gross estimates since efficiencies have not been determined for this source-detector geometry. Current efforts are focused on accurate determination of detector efficiencies using Monte Carlo calculations.

  19. Sensitivity Upgrades to the Idaho Accelerator Center Neutron Time of Flight Spectrometer

    SciTech Connect

    Thompson, S. J.; Kinlaw, M. T.; Harmon, J. F.; Wells, D. P.; Hunt, A. W.

    2007-10-26

    Past experiments have shown that discrimination between between fissionable and non-fissionable materials is possible using an interrogation technique that monitors for high energy prompt fission neutrons. Several recent upgrades have been made to the neutron time of flight spectrometer at the Idaho Accelerator Center with the intent of increasing neutron detection sensitivity, allowing for system use in nonproliferation and security applications.

  20. HFIR cold neutron source moderator vessel design analysis

    SciTech Connect

    Chang, S.J.

    1998-04-01

    A cold neutron source capsule made of aluminum alloy is to be installed and located at the tip of one of the neutron beam tubes of the High Flux Isotope Reactor. Cold hydrogen liquid of temperature approximately 20 degree Kelvin and 15 bars pressure is designed to flow through the aluminum capsule that serves to chill and to moderate the incoming neutrons produced from the reactor core. The cold and low energy neutrons thus produced will be used as cold neutron sources for the diffraction experiments. The structural design calculation for the aluminum capsule is reported in this paper.

  1. Proton recoil spectroscopy 400 meters from a fission neutron source

    SciTech Connect

    Stanka, M.B.

    1994-12-31

    Neutron kerma and spectrum measurements have been made at the US Army Pulse Radiation Facility (APRF) to 400m in an air-over-ground geometry from a fission neutron source and have been compared to Monte Carlo transport calculations. The neutron spectra measurements were made using a rotating neutron spectrometer. This spectrometer consists of four spherical proton-recoil detectors mounted on a common rotating base. Detector radius, gas composition, and pressure have been varied to allow sensitivity over a neutron range of 50 keV to 4.5 MeV. Neutron kerma was determined by using the Kerr soft-tissue kerma factors. Measured neutron kerma agreed with the calculated neutron kerma to within 5%. Comparisons with other neutron spectrometers such as NE213 and Bonner Spheres are presented and agreement between the different spectrometers is better than 20%.

  2. Neutron generator for BNCT based on high current ECR ion source with gyrotron plasma heating.

    PubMed

    Skalyga, V; Izotov, I; Golubev, S; Razin, S; Sidorov, A; Maslennikova, A; Volovecky, A; Kalvas, T; Koivisto, H; Tarvainen, O

    2015-12-01

    BNCT development nowadays is constrained by a progress in neutron sources design. Creation of a cheap and compact intense neutron source would significantly simplify trial treatments avoiding use of expensive and complicated nuclear reactors and accelerators. D-D or D-T neutron generator is one of alternative types of such sources for. A so-called high current quasi-gasdynamic ECR ion source with plasma heating by millimeter wave gyrotron radiation is suggested to be used in a scheme of D-D neutron generator in the present work. Ion source of that type was developed in the Institute of Applied Physics of Russian Academy of Sciences (Nizhny Novgorod, Russia). It can produce deuteron ion beams with current density up to 700-800 mA/cm(2). Generation of the neutron flux with density at the level of 7-8·10(10) s(-1) cm(-2) at the target surface could be obtained in case of TiD2 target bombardment with deuteron beam accelerated to 100 keV. Estimations show that it is enough for formation of epithermal neutron flux with density higher than 10(9) s(-1) cm(-2) suitable for BNCT. Important advantage of described approach is absence of Tritium in the scheme. First experiments performed in pulsed regime with 300 mA, 45 kV deuteron beam directed to D2O target demonstrated 10(9) s(-1) neutron flux. This value corresponds to theoretical estimations and proofs prospects of neutron generator development based on high current quasi-gasdynamic ECR ion source. PMID:26302662

  3. SPALLATION NEUTRON SOURCE HIGH-POWER PROTECTION MODULE TEST STAND

    SciTech Connect

    Lee, Sung-Woo; Ball, Jeffrey Allen; Crofford, Mark T; Davidson Jr, Taylor L; Jones, Stacey L; Hardek, Thomas W

    2010-01-01

    The Spallation Neutron Source (SNS) High-Power Protection Module (HPM) provides interlocks and fast shutdown for the radio frequency (RF) system to protect the accelerating structures and high power RF (HPRF) Distribution System. The HPM has required some functional upgrades since the start of beam operations and an upgrade to the HPM test stand was required to support these added features. The HPM test stand currently verifies functionality, RF channel calibration, and measurement of the speed of shutdown to ensure the specifications are met. The upgraded test stand was implemented in a Field Programmable Gate Array (FPGA) to allow for future growth and flexibility. Work is currently progressing on automation of the test stand to better perform the required module calibration schedule.

  4. rf improvements for Spallation Neutron Source H- ion sourcea)

    NASA Astrophysics Data System (ADS)

    Kang, Y. W.; Fuja, R.; Goulding, R. H.; Hardek, T.; Lee, S.-W.; McCarthy, M. P.; Piller, M. C.; Shin, K.; Stockli, M. P.; Welton, R. F.

    2010-02-01

    The Spallation Neutron Source at Oak Ridge National Laboratory is ramping up the accelerated proton beam power to 1.4 MW and just reached 1 MW. The rf-driven multicusp ion source that originates from the Lawrence Berkeley National Laboratory has been delivering ˜38 mA H- beam in the linac at 60 Hz, 0.9 ms. To improve availability, a rf-driven external antenna multicusp ion source with a water-cooled ceramic aluminum nitride (AlN) plasma chamber is developed. Computer modeling and simulations have been made to analyze and optimize the rf performance of the new ion source. Operational statistics and test runs with up to 56 mA medium energy beam transport beam current identify the 2 MHz rf system as a limiting factor in the system availability and beam production. Plasma ignition system is under development by using a separate 13 MHz system. To improve the availability of the rf power system with easier maintenance, we tested a 70 kV isolation transformer for the 80 kW, 6% duty cycle 2 MHz amplifier to power the ion source from a grounded solid-state amplifier.

  5. PREFACE: Neutrino physics at spallation neutron sources

    NASA Astrophysics Data System (ADS)

    Avignone, F. T.; Chatterjee, L.; Efremenko, Y. V.; Strayer, M.

    2003-11-01

    Unique because of their super-light masses and tiny interaction cross sections, neutrinos combine fundamental physics on the scale of the miniscule with macroscopic physics on the scale of the cosmos. Starting from the ignition of the primal p-p chain of stellar and solar fusion reactions that signal star-birth, these elementary leptons (neutrinos) are also critical players in the life-cycles and explosive deaths of massive stars and the production and disbursement of heavy elements. Stepping beyond their importance in solar, stellar and supernova astrophysics, neutrino interactions and properties influence the evolution, dynamics and symmetries of the cosmos as a whole. Further, they serve as valuable probes of its material content at various levels of structure from atoms and nuclei to valence and sea quarks. In the light of the multitude of physics phenomena that neutrinos influence, it is imperative to enhance our understanding of neutrino interactions and properties to the maximum. This is accentuated by the recent evidence of finite neutrino mass and flavour mixing between generations that reverberates on the plethora of physics that neutrinos influence. Laboratory experiments using intense neutrino fluxes would allow precision measurements and determination of important neutrino reaction rates. These can then complement atmospheric, solar and reactor experiments that have enriched so valuably our understanding of the neutrino and its repertoire of physics applications. In particular, intermediate energy neutrino experiments can provide critical information on stellar and solar astrophysical processes, along with advancing our knowledge of nuclear structure, sub-nuclear physics and fundamental symmetries. So where should we look for such intense neutrino sources? Spallation neutron facilities by their design are sources of intense neutrino pulses that are produced as a by-product of neutron spallation. These neutrino sources could serve as unique laboratories

  6. SPALLATION NEUTRON SOURCE BEAM CURRENT MONITOR ELECTRONICS.

    SciTech Connect

    KESSELMAN,M.; DAWSON,W.C.

    2002-05-06

    This paper will discuss the present electronics design for the beam current monitor system to be used throughout the Spallation Neutron Source (SNS) under construction at Oak Ridge National Laboratory. The beam is composed of a micro-pulse structure due to the 402.5MHz RF, and is chopped into mini-pulses of 645ns duration with a 300ns gap, providing a macro-pulse of 1060 mini-pulses repeating at a 60Hz rate. Ring beam current will vary from about 15ma peak during studies, to about 50Amps peak (design to 100 amps). A digital approach to droop compensation has been implemented and initial test results presented.

  7. BNL feasibility studies of spallation neutron sources

    SciTech Connect

    Lee, Y.Y.; Ruggiero, A.G.; Van Steenbergen, A.; Weng, W.T.

    1995-12-01

    This paper is the summary of conceptual design studies of a 5 MW Pulsed Spallation Neutron Source (PSNS) conducted by an interdepartmental study group at Brookhaven National Laboratory. The study was made of two periods. First, a scenario based on the use of a 600 MeV Linac followed by two fast-cycling 3.6 GeV Synchrotrons was investigated. Then, in a subsequent period, the attention of the study was directed toward an Accumulator scenario with two options: (1) a 1.25 GeV normal conducting Linac followed by two Accumulator Rings, and (2) a 2.4 GeV superconducting Linac followed by a single Accumulator Ring. The study did not make any reference to a specific site.

  8. Laser Plasma Particle Accelerators: Large Fields for Smaller Facility Sources

    SciTech Connect

    Geddes, Cameron G.R.; Cormier-Michel, Estelle; Esarey, Eric H.; Schroeder, Carl B.; Vay, Jean-Luc; Leemans, Wim P.; Bruhwiler, David L.; Cary, John R.; Cowan, Ben; Durant, Marc; Hamill, Paul; Messmer, Peter; Mullowney, Paul; Nieter, Chet; Paul, Kevin; Shasharina, Svetlana; Veitzer, Seth; Weber, Gunther; Rubel, Oliver; Ushizima, Daniela; Bethel, Wes; Wu, John

    2009-03-20

    Compared to conventional particle accelerators, plasmas can sustain accelerating fields that are thousands of times higher. To exploit this ability, massively parallel SciDAC particle simulations provide physical insight into the development of next-generation accelerators that use laser-driven plasma waves. These plasma-based accelerators offer a path to more compact, ultra-fast particle and radiation sources for probing the subatomic world, for studying new materials and new technologies, and for medical applications.

  9. Compact RF ion source for industrial electrostatic ion accelerator.

    PubMed

    Kwon, Hyeok-Jung; Park, Sae-Hoon; Kim, Dae-Il; Cho, Yong-Sub

    2016-02-01

    Korea Multi-purpose Accelerator Complex is developing a single-ended electrostatic ion accelerator to irradiate gaseous ions, such as hydrogen and nitrogen, on materials for industrial applications. ELV type high voltage power supply has been selected. Because of the limited space, electrical power, and robust operation, a 200 MHz RF ion source has been developed. In this paper, the accelerator system, test stand of the ion source, and its test results are described. PMID:26932115

  10. Compact RF ion source for industrial electrostatic ion accelerator

    NASA Astrophysics Data System (ADS)

    Kwon, Hyeok-Jung; Park, Sae-Hoon; Kim, Dae-Il; Cho, Yong-Sub

    2016-02-01

    Korea Multi-purpose Accelerator Complex is developing a single-ended electrostatic ion accelerator to irradiate gaseous ions, such as hydrogen and nitrogen, on materials for industrial applications. ELV type high voltage power supply has been selected. Because of the limited space, electrical power, and robust operation, a 200 MHz RF ion source has been developed. In this paper, the accelerator system, test stand of the ion source, and its test results are described.

  11. New empirical formula for neutron dose level at the maze entrance of 15 MV medical accelerator facilities

    SciTech Connect

    Kim, Hong-Suk; Jang, Ki-Won; Park, Youn-Hwan; Kwon, Jeong-Wan; Choi, Ho-Sin; Lee, Jai-Ki; Kim, Jong-Kyung

    2009-05-15

    An easily applicable empirical formula was derived for use in the assessment of the photoneutron dose at the maze entrance of a 15 MV medical accelerator treatment room. The neutron dose equivalent rates around the Varian medical accelerator head calculated with the Monte Carlo code MCNPX were used as the source term in producing the base data. The dose equivalents were validated by measurements with bubble detectors. Irradiation geometry conditions expected to yield higher neutron dose rates in the maze were selected: a 20x20 cm{sup 2} irradiation field, gantry rotation plane parallel to the maze walls, and the photon beams directed to the opposite wall to the maze entrance. The neutron dose equivalents at the maze entrance were computed for 697 arbitrary single-bend maze configurations by extending the Monte Carlo calculations down to the maze entrance. Then, the empirical formula was derived by a multiple regression fit to the neutron dose equivalents at the maze entrance for all the different maze configurations. The goodness of the empirical formula was evaluated by applying it to seven operating medical accelerators of different makes. When the source terms were fixed, the neutron doses estimated from the authors' formula agreed better with the corresponding MCNPX simulations than the results of the Kersey method. In addition, compared with the Wu-McGinley formula, the authors' formula provided better estimates for the mazes with length longer than 8.5 m. There are, however, discrepancies between the measured dose rates and the estimated values from the authors' formula, particularly for the machines other than a Varian model. Further efforts are needed to characterize the neutron field at the maze entrance to reduce the discrepancies. Furthermore, neutron source terms for the machines other than a Varian model should be simulated or measured and incorporated into the formula for accurate extended application to a variety of models.

  12. A capture-gated neutron spectrometer for characterization of neutron sources and their shields

    NASA Astrophysics Data System (ADS)

    Holm, Philip; Peräjärvi, Kari; Ristkari, Samu; Siiskonen, Teemu; Toivonen, Harri

    2014-07-01

    A portable capture-gated neutron spectrometer was designed and built. The spectrometer consists of a boron-loaded scintillator. Data acquisition is performed in list-mode. 252Cf and AmBe sources and various neutron and gamma shields were used to characterize the response of the device. It is shown that both the unfolded capture-gated neutron spectrum and the singles spectrum up to 5 MeV should be utilized. Source identification is then possible and important information is revealed regarding the surroundings of the source. The detector's discrimination of neutrons from photons is relatively good; specifically, one out of 105 photons is misclassified as a neutron and, more importantly, this misclassification rate can be calculated precisely for different measurement environments and can be taken into account in setting alarm limits for neutron detection. The source and source shield identification capabilities of the detector make it an interesting asset for security applications.

  13. Converged accelerated finite difference scheme for the multigroup neutron diffusion equation

    SciTech Connect

    Terranova, N.; Mostacci, D.; Ganapol, B. D.

    2013-07-01

    Computer codes involving neutron transport theory for nuclear engineering applications always require verification to assess improvement. Generally, analytical and semi-analytical benchmarks are desirable, since they are capable of high precision solutions to provide accurate standards of comparison. However, these benchmarks often involve relatively simple problems, usually assuming a certain degree of abstract modeling. In the present work, we show how semi-analytical equivalent benchmarks can be numerically generated using convergence acceleration. Specifically, we investigate the error behavior of a 1D spatial finite difference scheme for the multigroup (MG) steady-state neutron diffusion equation in plane geometry. Since solutions depending on subsequent discretization can be envisioned as terms of an infinite sequence converging to the true solution, extrapolation methods can accelerate an iterative process to obtain the limit before numerical instability sets in. The obtained results have been compared to the analytical solution to the 1D multigroup diffusion equation when available, using FORTRAN as the computational language. Finally, a slowing down problem has been solved using a cascading source update, showing how a finite difference scheme performs for ultra-fine groups (104 groups) in a reasonable computational time using convergence acceleration. (authors)

  14. Assessment of the neutron cross section database for mercury for the ORNL spallation source

    SciTech Connect

    Leal, L.C.; Spencer, R.R.; Ingersoll, D.T.; Gabriel, T.A.

    1996-06-01

    Neutron source generation based on a high energy particle accelerator has been considered as an alternative to the canceled Advanced Neutron Source project at Oak Ridge National Laboratory. The proposed technique consists of a spallation neutron source in which neutrons are produced via the interaction of high-energy charged particles in a heavy metal target. Preliminary studies indicate that liquid mercury bombarded with GeV protons provides an excellent neutron source. Accordingly, a survey has been made of the available neutron cross-section data. Since it is expected that spectral modifiers, specifically moderators, will also be incorporated into the source design, the survey included thermal energy, resonance region, and high energy data. It was found that data of individual isotopes were almost non-existent and that the only evaluation found for the natural element had regions of missing data or discrepant data. Therefore, it appears that to achieve the desired degree of accuracy in the spallation source design it is necessary to re-evaluate the mercury database including making new measurements. During the presentation the currently available data will be presented and experiments proposed which can lead to design quality cross sections.

  15. Mobile-accelerator neutron-radiography system. Final report, February 1978-December 1983

    SciTech Connect

    Dance, W.E.; Carollo, S.F.; Bumgardner, H.M.

    1984-10-01

    The use of neutron radiography for the inspection and maintenance of large structures such as aircraft has been delayed by the absence of a mobile system particularly suited to the requirements of field use. This report describes the production, extensive field testing, evaluation and disposition of the first mobile neutron radiography system to satisfy the majority of requirements for field use. The system is based upon the concept of a mobile on-off neutron radiography system based on a sealed-tube ion accelerator as neutron source demonstrated earlier by the Vought Corporation. Primary features of the system are its self-propelled mobility, versatile positioning capability scaled to Army helicopter dimensions, an on-off beam capability, exposure capability measured in minutes, and suitability for AMMRC laboratory and field use. Included in the report are a description of all components of the system, an evaluation of the operation of the system, an evaluation of its radiographic capabilities, a description of installation elements for the AMMRC site, and recommendations for next-generation systems.

  16. Production, distribution and applications of californium-252 neutron sources.

    PubMed

    Martin, R C; Knauer, J B; Balo, P A

    2000-01-01

    The radioisotope 252Cf is routinely encapsulated into compact, portable, intense neutron sources with a 2.6-yr half-life. A source the size of a person's little finger can emit up to 10(11) neutrons s(-1). Californium-252 is used commercially as a reliable, cost-effective neutron source for prompt gamma neutron activation analysis (PGNAA) of coal, cement and minerals, as well as for detection and identification of explosives, land mines and unexploded military ordinance. Other uses are neutron radiography, nuclear waste assays, reactor start-up sources, calibration standards and cancer therapy. The inherent safety of source encapsulations is demonstrated by 30 yr of experience and by US Bureau of Mines tests of source survivability during explosions. The production and distribution center for the US Department of Energy (DOE) Californium Program is the Radiochemical Engineering Development Center (REDC) at Oak Ridge National Laboratory (ORNL). DOE sells 252Cf to commercial reencapsulators domestically and internationally. Sealed 252Cf sources are also available for loan to agencies and subcontractors of the US government and to universities for educational, research and medical applications. The REDC has established the Californium User Facility (CUF) for Neutron Science to make its large inventory of 252Cf sources available to researchers for irradiations inside uncontaminated hot cells. Experiments at the CUF include a land mine detection system, neutron damage testing of solid-state detectors, irradiation of human cancer cells for boron neutron capture therapy experiments and irradiation of rice to induce genetic mutations. PMID:11003521

  17. Neutron calibration sources in the Daya Bay experiment

    DOE PAGESBeta

    Liu, J.; Carr, R.; Dwyer, D. A.; Gu, W. Q.; Li, G. S.; McKeown, R. D.; Qian, X.; Tsang, R. H. M.; Wu, F. F.; Zhang, C.

    2015-07-09

    We describe the design and construction of the low rate neutron calibration sources used in the Daya Bay Reactor Anti-neutrino Experiment. Such sources are free of correlated gamma-neutron emission, which is essential in minimizing induced background in the anti-neutrino detector. Thus, the design characteristics have been validated in the Daya Bay anti-neutrino detector.

  18. The European scene regarding spallation neutron sources

    SciTech Connect

    Bauer, G.S.

    1996-06-01

    In Europe, a short pulse spallation neutron source, ISIS, has been operating for over 10 years, working its way up to a beam power level of 200 kW. A continuous source, SINQ, designed for a beam power of up to 1 MW, is scheduled to start operating at the end of 1996, and a detailed feasibility study has been completed for a 410 kW short pulse source, AUSTRON. Each of these sources seems to have settled for a target concept which is at or near the limits of its feasibility: The ISIS depleted uranium plate targets, heavy water cooled and Zircaloy clad, have so far not shown satisfactory service time and operation is likely to continue with a Ta-plate target, which, in the past has been used successfully for the equivalent of one full-beam-year before it was taken out of service due to degrading thermal properties. SINQ will initially use a rod target, made of Zircaloy only, but plans exist to move on to clad lead rods as quickly as possible. Apart from the not yet explored effect of hydrogen and helium production, there are also concerns about the generation of 7-Be in the cooling water from the spallation of oxygen, which might result in undesirably high radioactivity in the cooling plant room. A Liquid metal target, also under investigation for SINQ, would not only reduce this problem to a level of about 10 %, but would also minimize the risk of radiolytic corrosion in the beam interaction zone. Base on similar arguments, AUSTRON has been designed for edge cooled targets, but thermal and stress analyses show, that this concept is not feasible at higher power levels.

  19. A high-performance D-lithium neutron source for fusion technology testing

    SciTech Connect

    Lawrence, G.P.; Wangler, T.P.; Schriber, S.O.; Kemp, E.L.; Wilson, M.T.; Bhatia, T.S.; Neuschaefer, G.H.; Guy, F.W.; Armstrong, D.D.

    1989-03-01

    Recent advances in high-current linear accelerator technology have considerably increased the attractiveness of a deuterium-lithium high-energy neutron source for fusion materials and technology testing. This paper describes a new Los Alamos conceptual design for a deuteron accelerator aimed at meeting near-term flux requirements of an International Fusion Materials Irradiation Facility. The new neutron-source driver concept is based on the idea of multiple accelerator modules, with each module consisting of two 125-mA, 175-MHz radio-frequency quadrupoles funneling 3-MeV cw deuteron beams into a 35-MeV, 250-mA, 350-MHz drift-tube linac.

  20. Characterization of a Source Importance Function in an Accelerator-Driven System

    SciTech Connect

    Kim, Yonghee; Park, Won Seok; Park, Chang Kue

    2003-07-15

    An importance function of the external spallation neutrons in an accelerator-driven system (ADS) has been introduced and characterized to address the source multiplication in a subcritical blanket. For a model ADS problem with a central external source, the source importance function is evaluated with a neutron transport code system. For a homogeneous core, essential characteristics of the importance are identified from the viewpoint of spatial distributions and energy dependency, etc. The importance function is evaluated for two different beam tube diameters, and its dependency on the buffer thickness is also addressed. In order to assess the impact of the power distribution on the importance function, a heterogeneous core is considered, and its importance function is evaluated. The analyses show that the peak importance occurs in the inner fuel blanket zone, not in the central source region, and the neutron importance in a high-energy regime, above 7 to 20 MeV, is high and increases with the energy. Also, the effects of a neutron absorber on the source importance are studied, and it is found that the source importance could be drastically reduced by surrounding the source with a strong neutron absorber such as B{sub 4}C. In addition, the source importance function is compared with the conventional {lambda}-mode adjoint flux, which is used as an importance function of fission neutrons in critical reactors. The comparison reveals that the inhomogeneous source importance function could be quite similar to the homogeneous {lambda}-mode adjoint flux in both spatial and spectral distributions for a wide range of subcriticality.

  1. Fuel cycle for a fusion neutron source

    NASA Astrophysics Data System (ADS)

    Ananyev, S. S.; Spitsyn, A. V.; Kuteev, B. V.

    2015-12-01

    The concept of a tokamak-based stationary fusion neutron source (FNS) for scientific research (neutron diffraction, etc.), tests of structural materials for future fusion reactors, nuclear waste transmutation, fission reactor fuel production, and control of subcritical nuclear systems (fusion-fission hybrid reactor) is being developed in Russia. The fuel cycle system is one of the most important systems of FNS that provides circulation and reprocessing of the deuterium-tritium fuel mixture in all fusion reactor systems: the vacuum chamber, neutral injection system, cryogenic pumps, tritium purification system, separation system, storage system, and tritium-breeding blanket. The existing technologies need to be significantly upgraded since the engineering solutions adopted in the ITER project can be only partially used in the FNS (considering the capacity factor higher than 0.3, tritium flow up to 200 m3Pa/s, and temperature of reactor elements up to 650°C). The deuterium-tritium fuel cycle of the stationary FNS is considered. The TC-FNS computer code developed for estimating the tritium distribution in the systems of FNS is described. The code calculates tritium flows and inventory in tokamak systems (vacuum chamber, cryogenic pumps, neutral injection system, fuel mixture purification system, isotope separation system, tritium storage system) and takes into account tritium loss in the fuel cycle due to thermonuclear burnup and β decay. For the two facility versions considered, FNS-ST and DEMO-FNS, the amount of fuel mixture needed for uninterrupted operation of all fuel cycle systems is 0.9 and 1.4 kg, consequently, and the tritium consumption is 0.3 and 1.8 kg per year, including 35 and 55 g/yr, respectively, due to tritium decay.

  2. Fuel cycle for a fusion neutron source

    SciTech Connect

    Ananyev, S. S. Spitsyn, A. V. Kuteev, B. V.

    2015-12-15

    The concept of a tokamak-based stationary fusion neutron source (FNS) for scientific research (neutron diffraction, etc.), tests of structural materials for future fusion reactors, nuclear waste transmutation, fission reactor fuel production, and control of subcritical nuclear systems (fusion–fission hybrid reactor) is being developed in Russia. The fuel cycle system is one of the most important systems of FNS that provides circulation and reprocessing of the deuterium–tritium fuel mixture in all fusion reactor systems: the vacuum chamber, neutral injection system, cryogenic pumps, tritium purification system, separation system, storage system, and tritium-breeding blanket. The existing technologies need to be significantly upgraded since the engineering solutions adopted in the ITER project can be only partially used in the FNS (considering the capacity factor higher than 0.3, tritium flow up to 200 m{sup 3}Pa/s, and temperature of reactor elements up to 650°C). The deuterium–tritium fuel cycle of the stationary FNS is considered. The TC-FNS computer code developed for estimating the tritium distribution in the systems of FNS is described. The code calculates tritium flows and inventory in tokamak systems (vacuum chamber, cryogenic pumps, neutral injection system, fuel mixture purification system, isotope separation system, tritium storage system) and takes into account tritium loss in the fuel cycle due to thermonuclear burnup and β decay. For the two facility versions considered, FNS-ST and DEMO-FNS, the amount of fuel mixture needed for uninterrupted operation of all fuel cycle systems is 0.9 and 1.4 kg, consequently, and the tritium consumption is 0.3 and 1.8 kg per year, including 35 and 55 g/yr, respectively, due to tritium decay.

  3. MANTRA: Measuring Neutron Capture Cross Sections in Actinides with Accelerator Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Bauder, W.; Pardo, R. C.; Collon, P.; Palchan, T.; Scott, R.; Vondrasek, R.; Nusair, O.; Nair, C.; Paul, M.; Kondev, F.; Chen, J.; Youinou, G.; Salvatores, M.; Palmotti, G.; Berg, J.; Maddock, T.; Imel, G.

    2013-10-01

    With rising global energy needs, there is substantial interest in nuclear energy research. To explore possibilities for advanced fuel cycles, better neutron cross section data are needed for the minor actinides. The MANTRA (Measurement of Actinide Neutron TRAsmutation) project will improve these data by measuring integral (n, γ) cross sections. The cross sections will be extracted by measuring isotopic ratios in pure actinide samples, irradiated in the Advanced Test Reactor at Idaho National Lab, using Accelerator Mass Spectrometry(AMS) at the Argonne Tandem Linac Accelerator System (ATLAS). MANTRA presents a unique AMS challenge because of the goal to measure multiple isotopic ratios on a large number of samples. To meet these challenges, we have modified the AMS setup at ATLAS to include a laser ablation system for solid material injection into our ECR ion source. I will present work on the laser ablation system and modified source geometry, as well as preliminary measurements of unirradiated actinide samples at ATLAS. This work was supported by the U.S. Department of Energy, Office of Nuclear Physics, under Contract No. DE-AC02-06CH11357.

  4. High-flux neutron source based on a liquid-lithium target

    SciTech Connect

    Halfon, S.; Feinberg, G.; Paul, M.; Arenshtam, A.; Berkovits, D.; Kijel, D.; Nagler, A.; Eliyahu, I.; Silverman, I.

    2013-04-19

    A prototype compact Liquid Lithium Target (LiLiT), able to constitute an accelerator-based intense neutron source, was built. The neutron source is intended for nuclear astrophysical research, boron neutron capture therapy (BNCT) in hospitals and material studies for fusion reactors. The LiLiT setup is presently being commissioned at Soreq Nuclear research Center (SNRC). The lithium target will produce neutrons through the {sup 7}Li(p,n){sup 7}Be reaction and it will overcome the major problem of removing the thermal power generated by a high-intensity proton beam, necessary for intense neutron flux for the above applications. The liquid-lithium loop of LiLiT is designed to generate a stable lithium jet at high velocity on a concave supporting wall with free surface toward the incident proton beam (up to 10 kW). During off-line tests, liquid lithium was flown through the loop and generated a stable jet at velocity higher than 5 m/s on the concave supporting wall. The target is now under extensive test program using a high-power electron-gun. Up to 2 kW electron beam was applied on the lithium flow at velocity of 4 m/s without any flow instabilities or excessive evaporation. High-intensity proton beam irradiation will take place at SARAF (Soreq Applied Research Accelerator Facility) superconducting linear accelerator currently in commissioning at SNRC.

  5. High-flux neutron source based on a liquid-lithium target

    NASA Astrophysics Data System (ADS)

    Halfon, S.; Feinberg, G.; Paul, M.; Arenshtam, A.; Berkovits, D.; Kijel, D.; Nagler, A.; Eliyahu, I.; Silverman, I.

    2013-04-01

    A prototype compact Liquid Lithium Target (LiLiT), able to constitute an accelerator-based intense neutron source, was built. The neutron source is intended for nuclear astrophysical research, boron neutron capture therapy (BNCT) in hospitals and material studies for fusion reactors. The LiLiT setup is presently being commissioned at Soreq Nuclear research Center (SNRC). The lithium target will produce neutrons through the 7Li(p,n)7Be reaction and it will overcome the major problem of removing the thermal power generated by a high-intensity proton beam, necessary for intense neutron flux for the above applications. The liquid-lithium loop of LiLiT is designed to generate a stable lithium jet at high velocity on a concave supporting wall with free surface toward the incident proton beam (up to 10 kW). During off-line tests, liquid lithium was flown through the loop and generated a stable jet at velocity higher than 5 m/s on the concave supporting wall. The target is now under extensive test program using a high-power electron-gun. Up to 2 kW electron beam was applied on the lithium flow at velocity of 4 m/s without any flow instabilities or excessive evaporation. High-intensity proton beam irradiation will take place at SARAF (Soreq Applied Research Accelerator Facility) superconducting linear accelerator currently in commissioning at SNRC.

  6. Initial tests of the Spallation Neutron Source H{sup -} ion source with an external antenna

    SciTech Connect

    Welton, R.F.; Stockli, M.P.; Murray, S.N.; Kang, Y.; Peters, J.

    2006-03-15

    The ion source for the Spallation Neutron Source (SNS) is a radio-frequency (rf) multicusp source designed to deliver H{sup -} beam pulses of 40 mA to the SNS accelerator with a normalized root-mean-square emittance of less than 0.2{pi} mm mrad, with a pulse length of 1 ms and a repetition rate of 60 Hz. In order to achieve this performance the source must operate with both high-pulse rf power, {approx}50 kW, and high average rf power, {approx}3.5 kW, over a continuous operational period of 3 weeks. During operation at these power levels the plasma-immersed, porcelain-coated rf antenna is susceptible to damage, limiting source lifetime. We are therefore developing an ion source where the plasma is separated from the Cu antenna by an Al{sub 2}O{sub 3} discharge chamber. This article describes the ion source, presents initial beam extraction measurements, and details our ongoing effort to develop this concept into a suitable ion source for the SNS.

  7. AREAL test facility for advanced accelerator and radiation source concepts

    NASA Astrophysics Data System (ADS)

    Tsakanov, V. M.; Amatuni, G. A.; Amirkhanyan, Z. G.; Aslyan, L. V.; Avagyan, V. Sh.; Danielyan, V. A.; Davtyan, H. D.; Dekhtiarov, V. S.; Gevorgyan, K. L.; Ghazaryan, N. G.; Grigoryan, B. A.; Grigoryan, A. H.; Hakobyan, L. S.; Haroutiunian, S. G.; Ivanyan, M. I.; Khachatryan, V. G.; Laziev, E. M.; Manukyan, P. S.; Margaryan, I. N.; Markosyan, T. M.; Martirosyan, N. V.; Mehrabyan, Sh. A.; Mkrtchyan, T. H.; Muradyan, L. Kh.; Nikogosyan, G. H.; Petrosyan, V. H.; Sahakyan, V. V.; Sargsyan, A. A.; Simonyan, A. S.; Toneyan, H. A.; Tsakanian, A. V.; Vardanyan, T. L.; Vardanyan, A. S.; Yeremyan, A. S.; Zakaryan, S. V.; Zanyan, G. S.

    2016-09-01

    Advanced Research Electron Accelerator Laboratory (AREAL) is a 50 MeV electron linear accelerator project with a laser driven RF gun being constructed at the CANDLE Synchrotron Research Institute. In addition to applications in life and materials sciences, the project aims as a test facility for advanced accelerator and radiation source concepts. In this paper, the AREAL RF photoinjector performance, the facility design considerations and its highlights in the fields of free electron laser, the study of new high frequency accelerating structures, the beam microbunching and wakefield acceleration concepts are presented.

  8. Experimental Results on the First Short Pulse Laser Driven Neutron Source Powerful Enough For Applications In Radiography

    NASA Astrophysics Data System (ADS)

    Guler, Nevzat

    2012-10-01

    Short pulse laser driven neutron source can be a compact and relatively cheap way to produce neutrons with energies in excess of 10 MeV. It is based on short pulse laser driven ions interacting with a converter material to produce neutrons via separation or breakup mechanisms. Previous research on the short pulse laser driven ion acceleration has mainly concentrated on surface acceleration mechanisms, which typically yield isotropic emission of neutrons from the converter. Recent experiments performed with a high contrast laser at TRIDENT facility at LANL demonstrated laser driven ion acceleration mechanism based on the concept of relativistic transparency. This produced an intense beam of high energy (up to 80 MeV) deuterons directed into a Be converter to produce a forward peaked neutron flux with a record yield, on the order of 4.4x10^9 n/sr. The produced neutron beam had a pulse duration less than a nanosecond and an energy range between 2-80 MeV, peaking around 12 MeV. The neutrons in the energy range of 2.5 to 15 MeV were selected by the gated neutron imager to radiograph tungsten blocks of different thicknesses. We will present the results from the two acceleration mechanisms and the first short pulse laser generated neutron radiograph.

  9. Fusion-neutron measurements for magnetized liner inertial fusion experiments on the Z accelerator

    NASA Astrophysics Data System (ADS)

    Hahn, K. D.; Chandler, G. A.; Ruiz, C. L.; Cooper, G. W.; Gomez, M. R.; Slutz, S.; Sefkow, A. B.; Sinars, D. B.; Hansen, S. B.; Knapp, P. F.; Schmit, P. F.; Harding, E.; Jennings, C. A.; Awe, T. J.; Geissel, M.; Rovang, D. C.; Torres, J. A.; Bur, J. A.; Cuneo, M. E.; Glebov, V. Yu; Harvey-Thompson, A. J.; Herrman, M. C.; Hess, M. H.; Johns, O.; Jones, B.; Lamppa, D. C.; Lash, J. S.; Martin, M. R.; McBride, R. D.; Peterson, K. J.; Porter, J. L.; Reneker, J.; Robertson, G. K.; Rochau, G. A.; Savage, M. E.; Smith, I. C.; Styron, J. D.; Vesey, R. A.

    2016-05-01

    Several magnetized liner inertial fusion (MagLIF) experiments have been conducted on the Z accelerator at Sandia National Laboratories since late 2013. Measurements of the primary DD (2.45 MeV) neutrons for these experiments suggest that the neutron production is thermonuclear. Primary DD yields up to 3e12 with ion temperatures ∼2-3 keV have been achieved. Measurements of the secondary DT (14 MeV) neutrons indicate that the fuel is significantly magnetized. Measurements of down-scattered neutrons from the beryllium liner suggest ρRliner∼1g/cm2. Neutron bang times, estimated from neutron time-of-flight (nTOF) measurements, coincide with peak x-ray production. Plans to improve and expand the Z neutron diagnostic suite include neutron burn-history diagnostics, increased sensitivity and higher precision nTOF detectors, and neutron recoil-based yield and spectral measurements.

  10. Production, Distribution, and Applications of Californium-252 Neutron Sources

    SciTech Connect

    Balo, P.A.; Knauer, J.B.; Martin, R.C.

    1999-10-03

    The radioisotope {sup 252}Cf is routinely encapsulated into compact, portable, intense neutron sources with a 2.6-year half-life. A source the size of a person's little finger can emit up to 10{sup 11} neutrons/s. Californium-252 is used commercially as a reliable, cost-effective neutron source for prompt gamma neutron activation analysis (PGNAA) of coal, cement, and minerals, as well as for detection and identification of explosives, laud mines, and unexploded military ordnance. Other uses are neutron radiography, nuclear waste assays, reactor start-up sources, calibration standards, and cancer therapy. The inherent safety of source encapsulations is demonstrated by 30 years of experience and by U.S. Bureau of Mines tests of source survivability during explosions. The production and distribution center for the U. S Department of Energy (DOE) Californium Program is the Radiochemical Engineering Development Center (REDC) at Oak Ridge National Laboratory (ORNL). DOE sells The radioisotope {sup 252}Cf is routinely encapsulated into compact, portable, intense neutron sources with a 2.6- year half-life. A source the size of a person's little finger can emit up to 10 neutrons/s. Californium-252 is used commercially as a reliable, cost-effective neutron source for prompt gamma neutron activation analysis (PGNAA) of coal, cement, and minerals, as well as for detection and identification of explosives, laud mines, and unexploded military ordnance. Other uses are neutron radiography, nuclear waste assays, reactor start-up sources, calibration standards, and cancer therapy. The inherent safety of source encapsulations is demonstrated by 30 years of experience and by U.S. Bureau of Mines tests of source survivability during explosions. The production and distribution center for the U. S Department of Energy (DOE) Californium Program is the Radiochemical Engineering Development Center (REDC) at Oak Ridge National Laboratory(ORNL). DOE sells {sup 252}Cf to commercial

  11. H- radio frequency source development at the Spallation Neutron Sourcea)

    NASA Astrophysics Data System (ADS)

    Welton, R. F.; Dudnikov, V. G.; Gawne, K. R.; Han, B. X.; Murray, S. N.; Pennisi, T. R.; Roseberry, R. T.; Santana, M.; Stockli, M. P.; Turvey, M. W.

    2012-02-01

    The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent ˜38 mA peak current in the linac and an availability of ˜90%. H- beam pulses (˜1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, ˜60 kW) of a copper antenna that has been encased with a thickness of ˜0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of ˜99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of ˜75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance/installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to ˜100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

  12. Intense coherent terahertz generation from accelerator-based sources

    NASA Astrophysics Data System (ADS)

    Hama, Hiroyuki; Yasuda, Mafuyu; Kawai, Masayuki; Hinode, Fujio; Nanbu, Kenichi; Miyahara, Fusashi

    2011-05-01

    The development of terahertz (THz) technology and science relevant to accelerator-based sources has been rapid, based on laser and semiconductor physics. To assure further progress of this scientific field, extremely intense radiation, involving gigawatt-class peak power, is needed. In addition to discussing the prospects for typical accelerator-based THz sources, such as coherent synchrotron radiation (CSR) and free electron lasers (FELs), novel, advanced THz sources employing isochronous-ring and bunched-FEL approaches are proposed.

  13. The energy sources of CME acceleration

    NASA Astrophysics Data System (ADS)

    Allawi, H.; Pohjolainen, S.

    2012-11-01

    We investigate the possibility that during the fast acceleration phase of a coronal mass ejection (CME), a freely propagating shock wave could be launched. We test this hypothesis by calculating the speeds of blast waves by using the Taylor-Sedov equation in changing density solar atmosphere, and compare these speeds with the radio type II burst speeds during the CME event on 17 February 2000. The matching speeds and the realistic value of the blast wave energy, 10^{24} J, lead us to suggest that the CME acceleration phase may involve shocks separating from the initial CME driver.

  14. Neutron yield and induced radioactivity: a study of 235-MeV proton and 3-GeV electron accelerators.

    PubMed

    Hsu, Yung-Cheng; Lai, Bo-Lun; Sheu, Rong-Jiun

    2016-01-01

    This study evaluated the magnitude of potential neutron yield and induced radioactivity of two new accelerators in Taiwan: a 235-MeV proton cyclotron for radiation therapy and a 3-GeV electron synchrotron serving as the injector for the Taiwan Photon Source. From a nuclear interaction point of view, neutron production from targets bombarded with high-energy particles is intrinsically related to the resulting target activation. Two multi-particle interaction and transport codes, FLUKA and MCNPX, were used in this study. To ensure prediction quality, much effort was devoted to the associated benchmark calculations. Comparisons of the accelerators' results for three target materials (copper, stainless steel and tissue) are presented. Although the proton-induced neutron yields were higher than those induced by electrons, the maximal neutron production rates of both accelerators were comparable according to their respective beam outputs during typical operation. Activation products in the targets of the two accelerators were unexpectedly similar because the primary reaction channels for proton- and electron-induced activation are (p,pn) and (γ,n), respectively. The resulting residual activities and remnant dose rates as a function of time were examined and discussed. PMID:25628454

  15. Accelerator-Based Boron Neutron Capture Therapy and the Development of a Dedicated Tandem-Electrostatic-Quadrupole

    SciTech Connect

    Kreiner, A. J.; Di Paolo, H.; Burlon, A. A.; Valda, A. A.; Debray, M. E.; Somacal, H. R.; Minsky, D. M.; Kesque, J. M.; Giboudot, Y.; Levinas, P.; Fraiman, M.; Romeo, V.

    2007-10-26

    There is a generalized perception that the availability of suitable particle accelerators installed in hospitals, as neutron sources, may be crucial for the advancement of Boron Neutron Capture Therapy (BNCT). Progress on an ongoing project to develop a Tandem-ElectroStatic-Quadrupole (TESQ) accelerator for Accelerator-Based (AB)-BNCT is described here. The project goal is a machine capable of delivering 30 mA of 2.5 MeV protons to be used in conjunction with a neutron production target based on the {sup 7}Li(p,n){sup 7}Be reaction slightly beyond its resonance at 2.25 MeV. A folded tandem, with 1.25 MV terminal voltage, combined with an ESQ chain is being designed and constructed. A 30 mA proton beam of 2.5 MeV are the specifications needed to produce sufficiently intense and clean epithermal neutron beams, based on the {sup 7}Li(p,n){sup 7}Be reaction, to perform BNCT treatment for deep-seated tumors in less than an hour. The first design and construction of an ESQ module is discussed and its electrostatic fields are investigated theoretically and experimentally. Also new beam transport calculations through the accelerator are presented.

  16. Fissile mass estimation by pulsed neutron source interrogation

    NASA Astrophysics Data System (ADS)

    Israelashvili, I.; Dubi, C.; Ettedgui, H.; Ocherashvili, A.; Pedersen, B.; Beck, A.; Roesgen, E.; Crochmore, J. M.; Ridnik, T.; Yaar, I.

    2015-06-01

    Passive methods for detecting correlated neutrons from spontaneous fissions (e.g. multiplicity and SVM) are widely used for fissile mass estimations. These methods can be used for fissile materials that emit a significant amount of fission neutrons (like plutonium). Active interrogation, in which fissions are induced in the tested material by an external continuous source or by a pulsed neutron source, has the potential advantages of fast measurement, alongside independence of the spontaneous fissions of the tested fissile material, thus enabling uranium measurement. Until recently, using the multiplicity method, for uranium mass estimation, was possible only for active interrogation made with continues neutron source. Pulsed active neutron interrogation measurements were analyzed with techniques, e.g. differential die away analysis (DDA), which ignore or implicitly include the multiplicity effect (self-induced fission chains). Recently, both, the multiplicity and the SVM techniques, were theoretically extended for analyzing active fissile mass measurements, made by a pulsed neutron source. In this study the SVM technique for pulsed neutron source is experimentally examined, for the first time. The measurements were conducted at the PUNITA facility of the Joint Research Centre in Ispra, Italy. First promising results, of mass estimation by the SVM technique using a pulsed neutron source, are presented.

  17. Superthermal source of ultracold neutrons for fundamental physics experiments.

    PubMed

    Zimmer, Oliver; Piegsa, Florian M; Ivanov, Sergey N

    2011-09-23

    Ultracold neutrons (UCNs) play an important role for precise measurements of the properties of the neutron and its interactions. During the past 25 years, a neutron turbine coupled to a liquid deuterium cold neutron source at a high-flux reactor has defined the state of the art for UCN production, despite a long history of efforts towards a new generation of UCN sources. This Letter reports a world-best UCN density available for users, achieved with a new source based on conversion of cold neutrons in superfluid helium. A conversion volume of 5 liters provides at least 274,000 UCN in a single accumulation run. Cyclically repeated operation of the source has been demonstrated, as well. PMID:22026860

  18. Superthermal Source of Ultracold Neutrons for Fundamental Physics Experiments

    SciTech Connect

    Zimmer, Oliver; Piegsa, Florian M.; Ivanov, Sergey N.

    2011-09-23

    Ultracold neutrons (UCNs) play an important role for precise measurements of the properties of the neutron and its interactions. During the past 25 years, a neutron turbine coupled to a liquid deuterium cold neutron source at a high-flux reactor has defined the state of the art for UCN production, despite a long history of efforts towards a new generation of UCN sources. This Letter reports a world-best UCN density available for users, achieved with a new source based on conversion of cold neutrons in superfluid helium. A conversion volume of 5 liters provides at least 274 000 UCN in a single accumulation run. Cyclically repeated operation of the source has been demonstrated, as well.

  19. Neutron energy spectrum adjustment using deposited metal films on Teflon in the miniature neutron source reactor.

    PubMed

    Nassan, L; Abdallah, B; Omar, H; Sarheel, A; Alsomel, N; Ghazi, N

    2016-01-01

    The focus of this article was on the experimental estimation of the neutron energy spectrum in the inner irradiation site of the miniature neutron source reactor (MNSR), using, for the first time, a selected set of deposited metal films on Teflon (DMFTs) neutron detectors. Gold, copper, zinc, titanium, aluminum, nickel, silver, and chromium were selected because of the dependence of their neutron cross-sections on neutron energy. Emphasis was placed on the usability of this new type of neutron detectors in the total neutron energy spectrum adjustment. The measured saturation activities per target nucleus values of the DMFTs, and the calculated neutron spectrum in the inner irradiation site using the MCNP-4C code were used as an input for the STAY'SL computer code during the adjustment procedure. The agreement between the numerically calculated and experimentally adjusted spectra results was discussed. PMID:26562448

  20. High-performance deuterium-lithium neutron source for fusion materials and technology testing

    SciTech Connect

    Lawrence, G.P.; Bhatia, T.S.; Blind, B.; Guy, F.W.; Krakowski, R.A.; Neuschaefer, G.H.; Schnurr, N.M.; Schriber, S.O.; Varsamis, G.L.; Wangler, T.P.

    1989-01-01

    Advances in high-current linear-accelerator technology since the design of the Fusion Materials Irradiation Test (FMIT) Facility have increased the attractiveness of a deuterium-lithium (D-Li) neutron source for fusion materials and technology testing. This paper discusses a new approach to such a source aimed at meeting the near-term requirements of a high-flux high-energy International Fusion Materials Irradiation Facility (IFMIF). The concept employs multiple accelerator modules providing deuteron beams to two liquid-lithium jet targets oriented at right angles. This beam/target geometry provides much larger test volumes than can be attained with a single beam and target and produces significant regions of low neutron-flux gradient. A preliminary beam-dynamics design has been obtained for a 250-mA reference accelerator module. Neutron-flux levels and irradiation volumes were calculated for a neutron source incorporating two such modules, and interaction of the beam with the lithium jet was studied using a thermal-hydraulic computer simulation. Cost estimates are provided for a range of beam currents and a possible facility staging sequence is suggested. 12 refs., 7 figs., 3 tabs.

  1. A Dipole Assisted IEC Neutron Source

    SciTech Connect

    Prajakti Joshi Shrestha

    2005-11-28

    A potential opportunity to enhance Inertial Electrostatic Confinement (IEC) fusion exists by augmenting it with a magnetic dipole configuration. The theory is that the dipole fields will enhance the plasma density in the center region of the IEC and the combined IEC and dipole confinement properties will reduce plasma losses. To demonstrate that a hybrid Dipole-IEC configuration can provide an improved neutron source vs. a stand alone IEC, a first model Dipole-IEC experiment was benchmarked against a reference IEC. A triple Langmuir probe was used to find the electron temperature and density. It was found that the magnetic field increases the electron density by a factor of 16, the electron temperature decreases in the presence of a magnetic field, the discharge voltage decreases in the presence of a magnetic field, the potential of the dipole strongly influences the densities obtained in the center. The experimental set-up and plasma diagnostics are discussed in detail, as well as the results, and the developmental issues.

  2. Advanced Neutron Source (ANS) Project Progress report, FY 1991

    SciTech Connect

    Campbell, J.H.; Selby, D.L.; Harrington, R.M.; Thompson, P.B.

    1992-01-01

    This report discusses the following about the Advanced Neutron Source: Project Management; Research and Development; Fuel Development; Corrosion Loop Tests and Analyses; Thermal-Hydraulic Loop Tests; Reactor Control and Shutdown Concepts; Critical and Subcritical Experiments; Material Data, Structural Tests, and Analysis; Cold-Source Development; Beam Tube, Guide, and Instrument Development; Hot-Source Development; Neutron Transport and Shielding; I & C Research and Development; Design; and Safety.

  3. Advanced Neutron Source (ANS) Project Progress report, FY 1991

    SciTech Connect

    Campbell, J.H. ); Selby, D.L.; Harrington, R.M. ); Thompson, P.B. . Engineering Division)

    1992-01-01

    This report discusses the following about the Advanced Neutron Source: Project Management; Research and Development; Fuel Development; Corrosion Loop Tests and Analyses; Thermal-Hydraulic Loop Tests; Reactor Control and Shutdown Concepts; Critical and Subcritical Experiments; Material Data, Structural Tests, and Analysis; Cold-Source Development; Beam Tube, Guide, and Instrument Development; Hot-Source Development; Neutron Transport and Shielding; I C Research and Development; Design; and Safety.

  4. Pulsed neutron source cold moderators --- concepts, design and engineering

    SciTech Connect

    Bauer, Guenter S.

    1997-01-01

    Moderator design for pulsed neutron sources is becoming more and more an interface area between source designers and instrument designers. Although there exists a high degree of flexibility, there are also physical and technical limitations. This paper aims at pointing out these limitations and examining ways to extend the current state of moderator technology in order to make the next generation neutron sources even more versatile and flexible tools for science in accordance with the users' requirements. (auth)

  5. Estimation of thermal neutron fluences in the concrete of proton accelerator facilities from 36Cl production

    NASA Astrophysics Data System (ADS)

    Bessho, K.; Matsumura, H.; Miura, T.; Wang, Q.; Masumoto, K.; Hagura, H.; Nagashima, Y.; Seki, R.; Takahashi, T.; Sasa, K.; Sueki, K.; Matsuhiro, T.; Tosaki, Y.

    2007-06-01

    The thermal neutron fluence that poured into the shielding concrete of proton accelerator facilities was estimated from the in situ production of 36Cl. The thermal neutron fluences at concrete surfaces during 10-30 years of operation were in the range of 1012-1014 n/cm2. The maxima in thermal neutron fluences were observed at ≈5-15 cm in the depths analyzed for 36Cl/35Cl by AMS. These characteristics imply that thermalization of neutrons occurred inside the concrete. Compared to the several tens of MeV cyclotrons, secondary neutrons penetrate deeper into the concrete at the high-energy accelerators possessing acceleration energies of 400 MeV and 12 GeV. The attenuation length of neutrons reflects the energy spectra of secondary neutrons emitted by the nuclear reaction at the beam-loss points. Increasing the energy of secondary neutrons shifts the maximum in the thermal neutron fluences to deeper positions. The data obtained in this study will be useful for the radioactive waste management at accelerator facilities.

  6. Development of a moderator system for the High Brilliance Neutron Source project

    NASA Astrophysics Data System (ADS)

    Dabruck, J. P.; Cronert, T.; Rücker, U.; Bessler, Y.; Klaus, M.; Lange, C.; Butzek, M.; Hansen, W.; Nabbi, R.; Brückel, T.

    2016-11-01

    The project for an accelerator based high brilliance neutron source HBS driven by Forschungszentrum Jülich forsees the use of the nuclear Be(p,n) or Be(d,n) reaction with accelerated particles in the lower MeV energy range. The lower neutron production compared to spallation has to be compensated by improving the neutron extraction process and optimizing the brilliance. Design and optimiziation of the moderator system are conducted with MCNP and will be validated with measurements at the AKR-2 training reactor by means of a prototype assembly where, e.g., the effect of different liquid H2 ortho/para ratios will be investigated and controlled in realtime via online heat capacity measurements.

  7. Fundamental neutron physics at a 1 MW long pulse spallation neutron source

    SciTech Connect

    Greene, G.L.

    1995-12-31

    Modern neutron sources and modern neutron science share a common origin in mid twentieth century scientific investigations concerned with the study of the fundamental interactions between elementary particles. Since the time of that common origin, neutron science and the study of elementary particles have evolved into quite disparate disciplines. The neutron became recognized as a powerful tool for the study of condensed matter with modern neutron sources being primarily used (and primarily justified) as tools for condensed matter research. The study of elementary particles has, of course, led to the development of rather different tools and is now dominated by activities carried out at extremely high energies. Notwithstanding this trend, the study of fundamental interactions using neutrons has continued and remains a vigorous activity at many contemporary neutron sources. This research, like neutron scattering research, has benefited enormously by the development of modern high flux neutron facilities. Future sources, particularly high power spallation sources, offer exciting possibilities for the continuation of this program of research.

  8. Rietveld refinement with time-of-flight powder diffraction data from pulsed neutron sources

    SciTech Connect

    David, W.I.F. ); Jorgensen, J.D. )

    1990-10-01

    The recent development of accelerator-based pulsed neutron sources has led to the widespread use of the time-of-flight technique for neutron powder diffraction. The properties of the pulsed source make possible unusually high resolution over a wide range of d spacings, high count rates, and the ability to collect complete data at fixed scattering angles. The peak shape and other instrument characteristics can be accurately modelled, which make Rietveld refinement possible for complex structures. In this paper we briefly review the development of the Rietveld method for time-of-flight diffraction data from pulsed neutron sources and discuss the latest developments in high resolution instrumentation and advanced Rietveld analysis methods. 50 refs., 12 figs., 14 tabs.

  9. Inertial electrostatic confinement I(IEC) neutron sources

    SciTech Connect

    Nebel, R.A.; Barnes, D.C.; Caramana, E.J.; Janssen, R.D.; Nystrom, W.D.; Tiouririne, T.N.; Trent, B.C.; Miley, G.H.; Javedani, J.

    1995-12-01

    Inertial Electrostatic Confinement (IEC) is one of the earliest plasma confinement concepts, having first been suggested by P.T. Farnsworth in the 1950s. The concept involves a simple apparatus of concentric spherical electrostatic grids or a combination of grids and magnetic fields. An electrostatic structure is formed from the confluence of electron or ion beams. Gridded IEC systems have demonstrated neutron yields as high as 2*10 [10]. neutrons/sec in steady state. These systems have considerable potential as small, inexpensive, portable neutron sources for assaying applications. Neutron tomography is also a potential application. This paper discusses the IEC concept and how it can be adapted to a steady-state assaying source and an intense pulsed neutron source. Theoretical modeling and experimental results are presented.

  10. Neutron dose per fluence and weighting factors for use at high energy accelerators

    SciTech Connect

    Cossairt, J.Donald; Vaziri, Kamran; /Fermilab

    2008-07-01

    In June 2007, the United States Department of Energy incorporated revised values of neutron weighting factors into its occupational radiation protection Regulation 10 CFR Part 835 as part of updating its radiation dosimetry system. This has led to a reassessment of neutron radiation fields at high energy proton accelerators such as those at the Fermi National Accelerator Laboratory (Fermilab). Values of dose per fluence factors appropriate for accelerator radiation fields calculated elsewhere are collated and radiation weighting factors compared. The results of this revision to the dosimetric system are applied to americium-beryllium neutron energy spectra commonly used for instrument calibrations. A set of typical accelerator neutron energy spectra previously measured at Fermilab are reassessed in light of the new dosimetry system. The implications of this revision are found to be of moderate significance.

  11. Acceleration of neutrons in a scheme of a tautochronous mathematical pendulum (physical principles)

    SciTech Connect

    Rivlin, Lev A

    2010-12-09

    We consider the physical principles of neutron acceleration through a multiple synchronous interaction with a gradient rf magnetic field in a scheme of a tautochronous mathematical pendulum. (laser applications and other aspects of quantum electronics)

  12. Neutron intensity monitor with activation foil for p-Li neutron source for BNCT--Feasibility test of the concept.

    PubMed

    Murata, Isao; Otani, Yuki; Sato, Fuminobu

    2015-12-01

    Proton-lithium (p-Li) reaction is being examined worldwide as a candidate nuclear production reaction for accelerator based neutron source (ABNS) for BNCT. In this reaction, the emitted neutron energy is not so high, below 1 MeV, and especially in backward angles the energy is as low as about 100 keV. The intensity measurement was thus known to be difficult so far. In the present study, a simple method was investigated to monitor the absolute neutron intensity of the p-Li neutron source by employing the foil activation method based on isomer production reactions in order to cover around several hundreds keV. As a result of numerical examination, it was found that (107)Ag, (115)In and (189)Os would be feasible. Their features found out are summarized as follows: (107)Ag: The most convenient foil, since the half life is short. (115)In: The accuracy is the best at 0°, though it cannot be used for backward angles. And (189)Os: Suitable nuclide which can be used in backward angles, though the gamma-ray energy is a little too low. These would be used for p-Li source monitoring depending on measuring purposes in real BNCT scenes. PMID:26242557

  13. Optimized thermal neutron source for neutron radiography with a static DIANE device

    NASA Astrophysics Data System (ADS)

    Cluzeau, S.; Huet, J.; Huriet, J. R.; Le Tourneur, P.

    1993-06-01

    The mobile neutron radiography DIANE device presented during the previous Denton accelerator conference and operating at Loral Vought Systems Corporation (USA) and IABG (Germany) is now also developed as a static device with a high resolution channel for parts inspection. For this purpose an optimized moderator has been designed which allows improvement in the thermal neutron flow. The theoretical approach and first experimental results are presented.

  14. Summary of alpha-neutron sources in GADRAS.

    SciTech Connect

    Mitchell, Dean James; Thoreson, Gregory G.; Harding, Lee T.

    2012-05-01

    A common source of neutrons for calibration and testing is alpha-neutron material, named for the alpha-neutron nuclear reaction that occurs within. This material contains a long-lived alpha-emitter and a lighter target element. When the alpha particle from the emitter is absorbed by the target, neutrons and gamma rays are released. Gamma Detector Response and Analysis Software (GADRAS) includes built-in alpha-neutron source definitions for AcC, AmB, AmBe, AmF, AmLi, CmC, and PuC. In addition, GADRAS users may create their own alpha-neutron sources by placing valid alpha-emitters and target elements in materials within their one-dimensional models (1DModel). GADRAS has the ability to use pre-built alpha-neutron sources for plotting or as trace-sources in 1D models. In addition, if any material (existing or user-defined) specified in a 1D model contains both an alpha emitter in conjunction with a target nuclide, or there is an interface between such materials, then the appropriate neutron-emission rate from the alpha-neutron reaction will be computed. The gamma-emissions from these sources are also computed, but are limited to a subset of nine target nuclides. If a user has experimental data to contribute to the alpha-neutron gamma emission database, it may be added directly or submitted to the GADRAS developers for inclusion. The gadras.exe.config file will be replaced when GADRAS updates are installed, so sending the information to the GADRAS developers is the preferred method for updating the database. This is also preferable because it enables other users to benefit from your efforts.

  15. Tagging fast neutrons from an (241)Am/(9)Be source.

    PubMed

    Scherzinger, J; Annand, J R M; Davatz, G; Fissum, K G; Gendotti, U; Hall-Wilton, R; Håkansson, E; Jebali, R; Kanaki, K; Lundin, M; Nilsson, B; Rosborge, A; Svensson, H

    2015-04-01

    Shielding, coincidence, and time-of-flight measurement techniques are employed to tag fast neutrons emitted from an (241)Am/(9)Be source resulting in a continuous polychromatic energy-tagged beam of neutrons with energies up to 7MeV. The measured energy structure of the beam agrees qualitatively with both previous measurements and theoretical calculations. PMID:25644080

  16. The LICORNE Neutron Source and Measurements of Prompt γ-rays Emitted in Fission

    NASA Astrophysics Data System (ADS)

    Wilson, J. N.; Lebois, M.; Halipre, P.; Oberstedt, S.; Oberstedt, A.

    The emission of prompt gamma rays is one of the least measured and least well-understood parts of the fission process. Knowledge of prompt fission gamma spectra, mean energies and multiplicities are important for reactor gamma heating and hence linked to reactor safety. At the IPN Orsay we have developed a unique, directional, fast neutron source called LICORNE, intended initially to facilitate prompt fission gamma measurements. The ability of the IPN Orsay tandem accelerator to produce intense beams of 7Li is exploited to produce quasi mono-energetic neutrons between 0.5 - 4 MeV using the p(7Li, 7Be)n inverse reaction. The available fluxes of up to 7×107 neutrons/second/steradian are comparable to existing installations, but with two added advantages: (i) The kinematic focusing produces a natural neutron beam collimation which allows placement of gamma detectors adjacent to the irradiated sample unimpeded by source neutrons. (ii) The background of scattered neutrons in the experimental hall is drastically reduced. The dedicated neutron converter was commissioned in June 2013

  17. Direct evidence for inelastic neutron 'acceleration' by {sup 177}Lu{sup m}

    SciTech Connect

    Roig, O.; Meot, V.; Rosse, B.; Belier, G.; Daugas, J.-M.; Morel, P.; Letourneau, A.; Menelle, A.

    2011-06-15

    The inelastic neutron acceleration cross section on the long-lived metastable state of {sup 177}Lu has been measured using a direct method. High-energy neutrons have been detected using a specially designed setup placed on a cold neutron beam extracted from the ORPHEE reactor in Saclay. The 146{+-}19 b inelastic neutron acceleration cross section in the ORPHEE cold neutron flux confirms the high cross section for this process on the {sup 177}Lu{sup m} isomer. The deviation from the 258{+-}58 b previously published obtained for a Maxwellian neutron flux at a 323 K temperature could be explained by the presence of a low energy resonance. Resonance parameters are deduced and discussed.

  18. Interaction of neutrons with a birefringent medium moving with an acceleration

    NASA Astrophysics Data System (ADS)

    Frank, A. I.

    2016-04-01

    Recent experiments demonstrated that the energy of a neutron traversing an accelerated sample of a refractive medium changes. Later, it was realized that such an accelerated-medium effect (AME) is quite a general phenomenon. This paper discusses some special features of the effect for a birefringent medium. In this case, AME shows quite new features. In neutron optics, where birefringence is due to the spin dependence of the refractive index, AME results in a nonstationary state with a precessing spin.

  19. First experimental results from 2MeV proton tandem accelerator for neutron productiona)

    NASA Astrophysics Data System (ADS)

    Kudryavtsev, A.; Belchenko, Yu.; Burdakov, A.; Davydenko, V.; Ivanov, A.; Khilchenko, A.; Konstantinov, S.; Krivenko, A.; Kuznetsov, A.; Mekler, K.; Sanin, A.; Shirokov, V.; Sorokin, I.; Sulyaev, Yu.; Tiunov, M.

    2008-02-01

    A 2MeV proton tandem accelerator with vacuum insulation was developed and first experiments are carried out in the Budker Institute of Nuclear Physics (Novosibirsk). The accelerator is designed for neutron production via reaction Li7(p,n)Be7 for the boron neutron-capture therapy of the brain tumors, and for explosive detection based on 9.1724MeV resonance gamma, which are produced via reaction C13(p,γ)N14, absorption in nitrogen.

  20. Mechanical Engineering of the Linac for the Spallation Neutron Source

    SciTech Connect

    Bultman, N.K.; Chen, Z.; Collier, M.; Erickson, J.L.; Guthrie, A.; Hunter, W.T.; Ilg, T.; Meyer, R.K.; Snodgrass, N.L.

    1999-03-29

    The linac for the Spallation Neutron Source (SNS) Project will accelerate an average current of 1 mA of H{sup {minus}} ions from 20 MeV to 1GeV for injection into an accumulator ring. The linac will be an intense source of H{sup {minus}} ions and as such requires advanced design techniques to meet project technical goals as well as to minimize costs. The DTL, CCDTL and CCL are 466m long and operate at 805 MHz with a maximum H{sup {minus}} input current of 28 mA and 7% rf duty factor. The Drift Tube Linac is a copper-plated steel structure using permanent magnetic quadrupoles. The Coupled-Cavity portions are brazed copper structures and use electromagnetic quads. RF losses in the copper are 80 MW, with total rf power supplied by 52 klystrons. Additionally, the linac is to be upgraded to the 2- and 4-MW beam power levels with no increase in duty factor. The authors give an overview of the linac mechanical engineering effort and discuss the special challenges and status of the effort.

  1. Advanced Neutron Source radiological design criteria

    SciTech Connect

    Westbrook, J.L.

    1995-08-01

    The operation of the proposed Advanced Neutron Source (ANS) facility will present a variety of radiological protection problems. Because it is desired to design and operate the ANS according to the applicable licensing standards of the Nuclear Regulatory Commission (NRC), it must be demonstrated that the ANS radiological design basis is consistent not only with state and Department of Energy (DOE) and other usual federal regulations, but also, so far as is practicable, with NRC regulations and with recommendations of such organizations as the Institute of Nuclear Power Operations (INPO) and the Electric Power Research Institute (EPRI). Also, the ANS radiological design basis is in general to be consistent with the recommendations of authoritative professional and scientific organizations, specifically the National Council on Radiation Protection and Measurements (NCRP) and the International Commission on Radiological Protection (ICRP). As regards radiological protection, the principal goals of DOE regulations and guidance are to keep occupational doses ALARA [as low as (is) reasonably achievable], given the current state of technology, costs, and operations requirements; to control and monitor contained and released radioactivity during normal operation to keep public doses and releases to the environment ALARA; and to limit doses to workers and the public during accident conditions. Meeting these general design objectives requires that principles of dose reduction and of radioactivity control by employed in the design, operation, modification, and decommissioning of the ANS. The purpose of this document is to provide basic radiological criteria for incorporating these principles into the design of the ANS. Operations, modification, and decommissioning will be covered only as they are affected by design.

  2. Evidence of source dominance in the dynamic behavior of accelerator-driven systems

    SciTech Connect

    Rydin, R.A.; Woosley, M.L. Jr.

    1997-07-01

    In a dynamic simulation method recently developed for accelerator-driven subcritical waste transmutation systems, power levels are renormalized dynamically based on the changing reactivity of the flowing system. For such systems, the power varies directly with the source strength, and inversely with the reactivity. The prompt-jump form of the point-kinetics equations has been used to provide the dynamic renormalization factor for the spatially dependent flowing-fuel system. A unique characteristic of the source-dominated system has been discovered. In the traditional reactor system, power changes are controlled by the half-life for decay of the longest-lived delayed neutron precursors. For the source-dominated system, the delayed neutron precursors do not appreciably slow the response of the system.

  3. Spallation neutron source target station design, development, and commissioning

    NASA Astrophysics Data System (ADS)

    Haines, J. R.; McManamy, T. J.; Gabriel, T. A.; Battle, R. E.; Chipley, K. K.; Crabtree, J. A.; Jacobs, L. L.; Lousteau, D. C.; Rennich, M. J.; Riemer, B. W.

    2014-11-01

    The spallation neutron source target station is designed to safely, reliably, and efficiently convert a 1 GeV beam of protons to a high flux of about 1 meV neutrons that are available at 24 neutron scattering instrument beam lines. Research and development findings, design requirements, design description, initial checkout testing, and results from early operation with beam are discussed for each of the primary target subsystems, including the mercury target, neutron moderators and reflector, surrounding vessels and shielding, utilities, remote handling equipment, and instrumentation and controls. Future plans for the mercury target development program are also briefly discussed.

  4. INSTRUMENTS AND METHODS OF INVESTIGATION: Giant pulses of thermal neutrons in large accelerator beam dumps. Possibilities for experiments

    NASA Astrophysics Data System (ADS)

    Stavissky, Yurii Ya

    2006-12-01

    A short review is presented of the development in Russia of intense pulsed neutron sources for physical research — the pulsating fast reactors IBR-1, IBR-30, IBR-2 (Joint Institute for Nuclear Research, Dubna), and the neutron-radiation complex of the Moscow meson factory — the 'Troitsk Trinity' (RAS Institute for Nuclear Research, Troitsk, Moscow region). The possibility of generating giant neutron pulses in beam dumps of superhigh energy accelerators is discussed. In particular, the possibility of producing giant pulsed thermal neutron fluxes in modified beam dumps of the large hadron collider (LHD) under construction at CERN is considered. It is shown that in the case of one-turn extraction ov 7-TeV protons accumulated in the LHC main rings on heavy targets with water or zirconium-hydride moderators placed in the front part of the LHC graphite beam-dump blocks, every 10 hours relatively short (from ~100 µs) thermal neutron pulses with a peak flux density of up to ~1020 neutrons cm-2 s-1 may be produced. The possibility of applying such neutron pulses in physical research is discussed.

  5. Status of the Advanced Photon Source (APS) linear accelerator

    SciTech Connect

    White, M.; Arnold, N.; Berg, W.; Cours, A.; Fuja, R.; Grelick, A.; Ko, K.; Qian, Y.; Russell, T.; Sereno, N.

    1994-09-01

    A 2856-MHz S-band, electron-positron linear accelerator (linac) has been constructed at the Advanced Photon Source (APS). It is the source of particles and the injector for the other APS accelerators, and linac commissioning is well underway. The linac is operated 24 hours per day to support linac beam studies and rf conditioning, as well as positron accumulator ring and synchrotron commissioning studies. The design goal for accelerated positron current is 8-mA, and has been met. Maximum positron energy to date is 420-MeV, approaching the design goal of 450-MeV. The linac design and its performance are discussed.

  6. Laser wakefield accelerator based light sources: potential applications and requirements

    SciTech Connect

    Albert, F.; Thomas, A. G.; Mangles, S. P.D.; Banerjee, S.; Corde, S.; Flacco, A.; Litos, M.; Neely, D.; Viera, J.; Najmudin, Z.; Bingham, R.; Joshi, C.; Katsouleas, T.

    2015-01-15

    In this article we review the prospects of laser wakefield accelerators as next generation light sources for applications. This work arose as a result of discussions held at the 2013 Laser Plasma Accelerators Workshop. X-ray phase contrast imaging, X-ray absorption spectroscopy, and nuclear resonance fluorescence are highlighted as potential applications for laser-plasma based light sources. We discuss ongoing and future efforts to improve the properties of radiation from plasma betatron emission and Compton scattering using laser wakefield accelerators for these specific applications.

  7. Fundamental neutron physics beamline at the spallation neutron source at ORNL

    DOE PAGESBeta

    Fomin, N.; Greene, G. L.; Allen, R. R.; Cianciolo, V.; Crawford, C.; Tito, T. M.; Huffman, P. R.; Iverson, E. B.; Mahurin, R.; Snow, W. M.

    2014-11-04

    In this paper, we describe the Fundamental Neutron Physics Beamline (FnPB) facility located at the Spallation Neutron Source at Oak Ridge National Laboratory. The FnPB was designed for the conduct of experiments that investigate scientific issues in nuclear physics, particle physics, astrophysics and cosmology using a pulsed slow neutron beam. Finally, we present a detailed description of the design philosophy, beamline components, and measured fluxes of the polychromatic and monochromatic beams.

  8. The Macromolecular Neutron Diffractometer MaNDi at the Spallation Neutron Source

    SciTech Connect

    Coates, Leighton; Cuneo, Matthew J.; Frost, Matthew J.; He, Junhong; Weiss, Kevin L.; McFeeters, Hana; Tomanicek, Stephen J.; Vandavasi, Venu Gopal; Langan, Paul; Iverson, Erik B.

    2015-07-18

    The Macromolecular Neutron Diffractometer (MaNDi) is located on beamline 11B of the Spallation Neutron Source at Oak Ridge National Laboratory. Moreover, the instrument is a neutron time-of-flight wavelength-resolved Laue diffractometer optimized to collect diffraction data from single crystals. Finally, the instrument has been designed to provide flexibility in several instrumental parameters, such as beam divergence and wavelength bandwidth, to allow data collection from a range of macromolecular systems.

  9. The Macromolecular Neutron Diffractometer MaNDi at the Spallation Neutron Source

    DOE PAGESBeta

    Coates, Leighton; Cuneo, Matthew J.; Frost, Matthew J.; He, Junhong; Weiss, Kevin L.; McFeeters, Hana; Tomanicek, Stephen J.; Vandavasi, Venu Gopal; Langan, Paul; Iverson, Erik B.

    2015-07-18

    The Macromolecular Neutron Diffractometer (MaNDi) is located on beamline 11B of the Spallation Neutron Source at Oak Ridge National Laboratory. Moreover, the instrument is a neutron time-of-flight wavelength-resolved Laue diffractometer optimized to collect diffraction data from single crystals. Finally, the instrument has been designed to provide flexibility in several instrumental parameters, such as beam divergence and wavelength bandwidth, to allow data collection from a range of macromolecular systems.

  10. Coded source neutron imaging with a MURA mask

    NASA Astrophysics Data System (ADS)

    Zou, Y. B.; Schillinger, B.; Wang, S.; Zhang, X. S.; Guo, Z. Y.; Lu, Y. R.

    2011-09-01

    In coded source neutron imaging the single aperture commonly used in neutron radiography is replaced with a coded mask. Using a coded source can improve the neutron flux at the sample plane when a very high L/ D ratio is needed. The coded source imaging is a possible way to reduce the exposure time to get a neutron image with very high L/ D ratio. A 17×17 modified uniformly redundant array coded source was tested in this work. There are 144 holes of 0.8 mm diameter on the coded source. The neutron flux from the coded source is as high as from a single 9.6 mm aperture, while its effective L/ D is the same as in the case of a 0.8 mm aperture. The Richardson-Lucy maximum likelihood algorithm was used for image reconstruction. Compared to an in-line phase contrast neutron image taken with a 1 mm aperture, it takes much less time for the coded source to get an image of similar quality.

  11. An ultra-cold neutron source at the MLNSC

    SciTech Connect

    Bowles, T.J.; Brun, T.; Hill, R.; Morris, C.; Seestrom, S.J.; Crow, L.; Serebrov, A.

    1998-11-01

    This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors have carried out the research and development of an Ultra-Cold Neutron (UCN) source at the Manuel Lujan Neutron Scattering Center (MLNSC). A first generation source was constructed to test the feasibility of a rotor source. The source performed well with an UCN production rate reasonably consistent with that expected. This source can now provide the basis for further development work directed at using UCN in fundamental physics research as well as possible applications in materials science.

  12. A route to the brightest possible neutron source?

    PubMed

    Taylor, Andrew; Dunne, Mike; Bennington, Steve; Ansell, Stuart; Gardner, Ian; Norreys, Peter; Broome, Tim; Findlay, David; Nelmes, Richard

    2007-02-23

    We review the potential to develop sources for neutron scattering science and propose that a merger with the rapidly developing field of inertial fusion energy could provide a major step-change in performance. In stark contrast to developments in synchrotron and laser science, the past 40 years have seen only a factor of 10 increase in neutron source brightness. With the advent of thermonuclear ignition in the laboratory, coupled to innovative approaches in how this may be achieved, we calculate that a neutron source three orders of magnitude more powerful than any existing facility can be envisaged on a 20- to 30-year time scale. Such a leap in source power would transform neutron scattering science. PMID:17322053

  13. Study of neutron focusing at the Texas Cold Neutron Source. Final report

    SciTech Connect

    Wehring, B.W.; Uenlue, K.

    1996-12-19

    The goals of this three-year study were: (1) design a neutron focusing system for use with the Texas Cold Neutron Source (TCNS) to produce an intense beam of cold neutrons appropriate for prompt gamma activation analysis (PGAA); (2) orchestrate the construction of the focusing system, integrate it into the TCNS neutron guide complex, and measure its performance; and (3) design, setup, and test a cold-neutron PGAA system which utilizes the guided focused cold neutron beam. During the first year of the DOE grant, a new procedure was developed and used to design a focusing converging guide consisting of truncated rectangular cone sections. Detailed calculations were performed using a 3-D Monte Carlo code which the authors wrote to trace neutrons through the curved guide of the TCNS into the proposed converging guide. Using realistic reflectivities for Ni-Ti supermirrors, the authors obtained gains of 3 to 5 for 4 different converging guide geometries. During the second year of the DOE grant, the subject of this final report, Ovonic Synthetic Materials Company was contracted to build a converging neutron guide focusing system to the specifications. Considerable time and effort were spent working with Ovonics on selecting the materials for the converging neutron guide system. The major portion of the research on the design of a cold-neutron PGAA system was also completed during the second year. At the beginning of the third year of the grant, a converging neutron guide focusing system had been ordered, and a cold-neutron PGAA system had been designed. Since DOE did not fund the third year, there was no money to purchase the required equipment for the cold-neutron PGAA system and no money to perform tests of either the converging neutron guide or the cold-neutron PGAA system. The research already accomplished would have little value without testing the systems which had been designed. Thus the project was continued at a pace that could be sustained with internal funding.

  14. rf improvements for Spallation Neutron Source H{sup -} ion source

    SciTech Connect

    Kang, Y. W.; Fuja, R.; Hardek, T.; Lee, S.-W.; McCarthy, M. P.; Piller, M. C.; Shin, K.; Stockli, M. P.; Welton, R. F.; Goulding, R. H.

    2010-02-15

    The Spallation Neutron Source at Oak Ridge National Laboratory is ramping up the accelerated proton beam power to 1.4 MW and just reached 1 MW. The rf-driven multicusp ion source that originates from the Lawrence Berkeley National Laboratory has been delivering {approx}38 mA H{sup -} beam in the linac at 60 Hz, 0.9 ms. To improve availability, a rf-driven external antenna multicusp ion source with a water-cooled ceramic aluminum nitride (AlN) plasma chamber is developed. Computer modeling and simulations have been made to analyze and optimize the rf performance of the new ion source. Operational statistics and test runs with up to 56 mA medium energy beam transport beam current identify the 2 MHz rf system as a limiting factor in the system availability and beam production. Plasma ignition system is under development by using a separate 13 MHz system. To improve the availability of the rf power system with easier maintenance, we tested a 70 kV isolation transformer for the 80 kW, 6% duty cycle 2 MHz amplifier to power the ion source from a grounded solid-state amplifier.

  15. Status of the Ultracold neutron source upgrade at LANSCE

    SciTech Connect

    Pattie, Robert Wayne Jr.

    2015-10-31

    Several slides show the source and flux of ultracold neutrons produced. In summary, an upgraded UCN source has been designed, and parts are currently being fabricated. Nickel phosphorus-coated guides will improve transport to the experiment hall. The source will be installed in the spring of 2016 and commissioned in the fall of 2016.

  16. Secondary neutron source modelling using MCNPX and ALEPH codes

    NASA Astrophysics Data System (ADS)

    Trakas, Christos; Kerkar, Nordine

    2014-06-01

    Monitoring the subcritical state and divergence of reactors requires the presence of neutron sources. But mainly secondary neutrons from these sources feed the ex-core detectors (SRD, Source Range Detector) whose counting rate is correlated with the level of the subcriticality of reactor. In cycle 1, primary neutrons are provided by sources activated outside of the reactor (e.g. Cf252); part of this source can be used for the divergence of cycle 2 (not systematic). A second family of neutron sources is used for the second cycle: the spontaneous neutrons of actinides produced after irradiation of fuel in the first cycle. Both families of sources are not sufficient to efficiently monitor the divergence of the second cycles and following ones, in most reactors. Secondary sources cluster (SSC) fulfil this role. In the present case, the SSC [Sb, Be], after activation in the first cycle (production of Sb124, unstable), produces in subsequent cycles a photo-neutron source by gamma (from Sb124)-neutron (on Be9) reaction. This paper presents the model of the process between irradiation in cycle 1 and cycle 2 results for SRD counting rate at the beginning of cycle 2, using the MCNPX code and the depletion chain ALEPH-V1 (coupling of MCNPX and ORIGEN codes). The results of this simulation are compared with two experimental results of the PWR 1450 MWe-N4 reactors. A good agreement is observed between these results and the simulations. The subcriticality of the reactors is about at -15,000 pcm. Discrepancies on the SRD counting rate between calculations and measurements are in the order of 10%, lower than the combined uncertainty of measurements and code simulation. This comparison validates the AREVA methodology, which allows having an SRD counting rate best-estimate for cycles 2 and next ones and optimizing the position of the SSC, depending on the geographic location of sources, main parameter for optimal monitoring of subcritical states.

  17. Design status of an intense 14 MeV neutron source for cancer therapy

    NASA Astrophysics Data System (ADS)

    Yao, Ze-En; Su, Tong-Ling; Cheng, Shang-Wen; Jia, Wen-Bao

    2002-09-01

    Design and development of an intense 14 MeV neutron source for cancer therapy is in progress at the Institute of Nuclear Research of Lanzhou University. The neutrons from the T(d,n) 4He reaction are produced by bombarding a rotating titanium tritide target with a 40 mA deuteron beam at 600 keV. The designed neutron yield is 8×10 12 n/s and the maximum dose rate at a 100 cm source-to-skin distance is 25 cGy/min. The HV terminal, accelerating column and HV power supply are enclosed inside a stainless steel pressure vessel containing 6 atm SF 6 gas to provide the electrical insulation.

  18. RESULTS OF BACKGROUND SUBTRACTION TECHNIQUES ON THE SPALLATION NEUTRON SOURCE BEAM LOSS MONITORS

    SciTech Connect

    Pogge, James R; Zhukov, Alexander P

    2010-01-01

    Recent improvements to the Spallation Neutron Source (SNS) beam loss monitor (BLM) designs have been made with the goal of significantly reducing background noise. This paper outlines this effort and analyzes the results. The significance of this noise reduction is the ability to use the BLM sensors [1], [2], [3] distributed throughout the SNS accelerator as a method to monitor activation of components as well as monitor beam losses.

  19. On the Neutron Kinetics and Control of Accelerator-Driven Systems

    SciTech Connect

    Cacuci, D.G.

    2004-09-15

    This work addresses fundamental aspects of the time- and space-dependent behavior of an Accelerator-Driven Subcritical Core System (ADS) and presents a paradigm ADS neutron kinetics model that is solved exactly. Thus, this paradigm model can serve for benchmarking two- and/or three-dimensional computational tools. Furthermore, this work also proposes a global optimal control theory framework for the operation and control of an ADS. This framework encompasses conceptually the time- and space-dependent behavior of the ADS coupled neutron kinetics/thermal-hydraulic balance equations and aims at the optimal control of ADS operational objectives, which would include minimization of local flux disturbances, load and source following, etc. Importantly, this new conceptual framework makes no use of a 'fictitious ADS steady state' and yields the correct and complete (i.e., including sources) adjoint equations, without leaving any room for ambiguities. Thus, this new conceptual framework provides a natural basis for developing new computational methods and corresponding verification experiments specifically tailored for the control and operation of ADS.

  20. Plans for a Collaboratively Developed Distributed Control System for the Spallation Neutron Source

    SciTech Connect

    DeVan, W.R.; Gurd, D.P.; Hammonds, J.; Lewis, S.A.; Smith, J.D.

    1999-03-29

    The Spallation Neutron Source (SNS) is an accelerator-based pulsed neutron source to be built in Oak Ridge, Tennessee. The facility has five major sections - a ''front end'' consisting of a 65 keV H{sup -} ion source followed by a 2.5 MeV RFQ; a 1 GeV linac; a storage ring; a 1MW spallation neutron target (upgradeable to 2 MW); the conventional facilities to support these machines and a suite of neutron scattering instruments to exploit them. These components will be designed and implemented by five collaborating institutions: Lawrence Berkeley National Laboratory (Front End), Los Alamos National Laboratory (Linac); Brookhaven National Laboratory (Storage Ring); Argonne National Laboratory (Instruments); and Oak Ridge National Laboratory (Neutron Source and Conventional Facilities). It is proposed to implement a fully integrated control system for all aspects of this complex. The system will be developed collaboratively, with some degree of local autonomy for distributed systems, but centralized accountability. Technical integration will be based upon the widely-used EPICS control system toolkit, and a complete set of hardware and software standards. The scope of the integrated control system includes site-wide timing and synchronization, networking and machine protection. This paper discusses the technical and organizational issues of planning a large control system to be developed collaboratively at five different institutions, the approaches being taken to address those issues, as well as some of the particular technical challenges for the SNS control system.

  1. The design of an intense accelerator-based epithermal neutron beam prototype for BNCT using near-threshold reactions

    NASA Astrophysics Data System (ADS)

    Lee, Charles L.

    Near-threshold boron neutron capture therapy (BNCT) uses proton energies only tens of rev above the (pan) reaction threshold in lithium in order to reduce the moderation requirements of the neutron source. The goals of this research were to prove the feasibility of this near-threshold concept for BNCT applications, using both calculation and experiment, and design a compact neutron source prototype from these results. This required a multidisciplinary development of methods for calculation of neutron yields, head phantom dosimetry, and accelerator target heat removal. First, a method was developed to accurately calculate thick target neutron yields for both near-threshold and higher energy proton beams, in lithium metal as well as lithium compounds. After these yields were experimentally verified, they were used as neutron sources for Monte Carlo (MCNP) simulations of neutron and photon transport in head phantoms. The theoretical and experimental determination of heat removal from a target backing with multiple fins, as well as numerical calculations of heat deposition profiles based on proton energy loss in target and backing materials, demonstrated that lithium integrity can be maintained for proton beam currents up to 2.5 mA. The final design uses a proton beam energy of 1.95 MeV and has a centerline epithermal neutron flux of 2.2 × 108 n/cm2- sec/mA, an advantage depth of 5.7 cm, an advantage ratio of 4.3, and an advantage depth dose rate of 6.7 RBE- cGy/min/mA, corresponding to an irradiation time of 38 minutes with a 5 mA beam. Moderator, reflector, and shielding weigh substantially less than other accelerator BNCT designs based on higher proton energies, e.g. 2.5 MeV. The near-threshold concept is useful as a portable neutron source for hospital settings, with applications ranging from glioblastomas to melanomas and synovectomy. (Copies available exclusively from MIT Libraries, Rm. 14- 0551, Cambridge, MA 02139-4307. Ph. 617-253-5668; Fax 617-253-1690.)

  2. Cosmic ray sources, acceleration and propagation

    NASA Technical Reports Server (NTRS)

    Ptuskin, V. S.

    1986-01-01

    A review is given of selected papers on the theory of cosmic ray (CR) propagation and acceleration. The high isotropy and a comparatively large age of galactic CR are explained by the effective interaction of relativistic particles with random and regular electromagnetic fields in interstellar medium. The kinetic theory of CR propagation in the Galaxy is formulated similarly to the elaborate theory of CR propagation in heliosphere. The substantial difference between these theories is explained by the necessity to take into account in some cases the collective effects due to a rather high density of relativisitc particles. In particular, the kinetic CR stream instability and the hydrodynamic Parker instability is studied. The interaction of relativistic particles with an ensemble of given weak random magnetic fields is calculated by perturbation theory. The theory of CR transfer is considered to be basically completed for this case. The main problem consists in poor information about the structure of the regular and the random galactic magnetic fields. An account is given of CR transfer in a turbulent medium.

  3. Accelerator-based Neutron Fluence Standard of the National Metrology Institute of Japan

    NASA Astrophysics Data System (ADS)

    Harano, Hideki; Matsumoto, Tetsuro; Nishiyama, Jun; Uritani, Akira; Kudo, Katsuhisa

    2009-03-01

    We report the present status of the national standard on accelerator-based fast neutron fluences in Japan. Monoenergetic neutron fluence standards have been established at 144 keV, 565 keV, 5.0 MeV and 8.0 MeV by using a Van de Graaff accelerator and at 2.5 MeV and 14.8 MeV by using a Cockcroft Walton accelerator. These standards are prepared to measure the detection efficiency and the energy response of neutron sensitive devices, such as personal dosimeters and survey meters. Neutron production and absolute fluence measurement for these energies are described. We are developing a new standard in the energy region of a few tens of keV, which is also introduced here as well as our future plans.

  4. Surface plasma source with anode layer plasma accelerator

    SciTech Connect

    Dudnikov, Vadim

    2012-02-15

    Proposed plasma generation system can be used for high current negative ion beam production and for directed deposition by flux of sputtered neutrals and negative ions. The main mechanism of negative ion formation in surface plasma sources is the secondary emission from low work function surface bombarded by a flux of positive ion or neutrals. The emission of negative ions is enhanced significantly by introducing a small amount of cesium or other substance with low ionization potential. In the proposed source are used positive ions generated by Hall drift plasma accelerator (anode layer plasma accelerator or plasma accelerator with insulated channel, with cylindrical or race track configuration of emission slit). The target-emitter is bombarded by the ion beam accelerated in crossed ExB fields. Negative ions are extracted from the target surface with geometrical focusing and are accelerated by negative voltage applied between emitter and plasma, contacting with the plasma accelerator. Hall drift ion source has a special design with a space for passing of the emitted negative ions and sputtered particles through the positive ion source.

  5. [Relative biological effectiveness of accelerated heavy ions and fast neutrons estimated from frequency of aberration mytoses in the retinal epithelium].

    PubMed

    Vorozhtsova, S V; Shafirkin, A V; Fedorenko, B S

    2006-01-01

    Analyzed was the literature and authors' experimental data concerning lesion and recovery of epithelium cells of mice retina immediately and long after irradiation at different sources including single and partly fractionated irradiation by gamma- and X-rays, accelerated protons, helium, carbon and boron ions, and fast neutrons of the reactor range in a large spectrum of doses and LET. Reviewed are some new techniques of determining the RBE coefficient for these types of radiation; large values of the RBE coefficients for accelerated ions and neutrons (5-10 times higher than RBE coefficients calculated for the next day following irradiation) are a result of integration into calculation of the available data about the delayed disorders in retinal epithelium cell regeneration. PMID:17193969

  6. Nuclear and dosimetric features of an isotopic neutron source

    NASA Astrophysics Data System (ADS)

    Vega-Carrillo, H. R.; Hernández-Dávila, V. M.; Rivera, T.; Sánchez, A.

    2014-02-01

    A multisphere neutron spectrometer was used to determine the features of a 239PuBe neutron source that is used to operate the ESFM-IPN Subcritical Reactor. To determine the source main features it was located a 100 cm from the spectrometer which was a 6LiI(Eu) scintillator and 2, 3, 5, 8, 10 and 12 in.-diameter polyethylene spheres. Count rates obtained with the spectrometer were unfolded using the NSDUAZ code and neutron spectrum, total fluence, and ambient dose equivalent were determined. A Monte Carlo calculation was carried out to estimate the spectrum and integral features being less than values obtained experimentally due to the presence of 241Pu in the Pu used to fabricate the source. Actual neutron yield and the mass fraction of 241Pu was estimated.

  7. Neutron-proton-converter acceleration mechanism at subphotospheres of relativistic outflows.

    PubMed

    Kashiyama, Kazumi; Murase, Kohta; Mészáros, Peter

    2013-09-27

    We study a type of particle acceleration that operates via neutron-proton conversion in inelastic nuclear collisions. This mechanism can be expected for relativistic shocks at subphotospheres if relativistic outflows contain neutrons. Using a test-particle approximation, we numerically calculate the energy spectrum and the efficiency of accelerated particles, and show that a good energy fraction of the nucleons can be accelerated. This mechanism may be especially relevant if the shock is radiation mediated, and it would enhance the detectability of GeV-TeV neutrinos. PMID:24116765

  8. Utilization of the intense pulsed neutron source (IPNS) at Argonne National Laboratory for neutron activation analysis

    SciTech Connect

    Heinrich, R.R.; Greenwood, L.R.; Popek, R.J.; Schulke, A.W. Jr.

    1983-01-01

    The Intense Pulsed Neutron Source (IPNS) neutron scattering facility (NSF) has been investigated for its applicability to neutron activation analysis. A polyethylene insert has been added to the vertical hole VT3 which enhances the thermal neutron flux by a factor of two. The neutron spectral distribution at this position has been measured by the multiple-foil technique which utilized 28 activation reactions and the STAYSL computer code. The validity of this spectral measurement was tested by two irradiations of National Bureau of Standards SRM-1571 (orchard leaves), SRM-1575 (pine needles), and SRM-1645 (river sediment). The average thermal neutron flux for these irradiations normalized to 10 ..mu..amp proton beam is 4.0 x 10/sup 11/ n/cm/sup 2/-s. Concentrations of nine trace elements in each of these SRMs have been determined by gamma-ray spectrometry. Agreement of measured values to certified values is demonstrated to be within experiment error.

  9. Towards detectors for next generation spallation neutron sources

    NASA Astrophysics Data System (ADS)

    Gebauer, B.

    2004-12-01

    Neutron scattering and diffraction methods are of utmost importance for probing the structure and dynamics of condensed matter at an atomic, molecular and mesoscopic level. However, today's experiments, using either wavelength-selected cw beams from steady-state reactor or spallation sources or, on the other hand, comparatively weak pulsed spallation source beams (with the exception of the pulsed IBR-2 reactor in Dubna), suffer from relatively low source strengths, e.g. compared to synchrotron-radiation investigations. Therefore, neutron scattering methods can greatly benefit from next generation pulsed spallation neutron sources with 1-10 MW average proton beam power, which will allow analyzing wavelengths by time-of-flight (TOF) and thus utilizing in an experiment simultaneously a large fraction of the full wavelength band. However, the improved instantaneous flux will pose great challenges on the detection systems, since for instance for ESS, the strongest of the projected sources, the peak thermal neutron flux will be higher by nearly two orders of magnitude than at the presently strongest sources. Owing to current improvements in neutron optics and spectrometer design, the fluxes impinging on the samples will be further enhanced by another factor 5-10; however, this will be compensated for by the tendency to investigate smaller samples becoming accessible due to smaller foci and higher beam fluxes. Hence, thermal neutron detectors with up to two orders of magnitude higher peak count rate capacity in conjunction with microsecond TOF and for some applications sub-millimeter position resolutions are required, in addition to other characteristics like e.g. high long-term stability and low sensitivity to photon background. In this review article an overview will be given on the current state-of-the-art and on currently investigated novel solutions for thermal neutron detectors for very high rate and resolution time-resolved experiments, comprising silicon

  10. Rationale for a spallation neutron source target system test facility at the 1-MW Long-Pulse Spallation Source

    SciTech Connect

    Sommer, W.F.

    1995-12-01

    The conceptual design study for a 1-MW Long-Pulse Spallation Source at the Los Alamos Neutron Science Center has shown the feasibility of including a spallation neutron test facility at a relatively low cost. This document presents a rationale for developing such a test bed. Currently, neutron scattering facilities operate at a maximum power of 0.2 MW. Proposed new designs call for power levels as high as 10 MW, and future transmutation activities may require as much as 200 MW. A test bed will allow assessment of target neutronics; thermal hydraulics; remote handling; mechanical structure; corrosion in aqueous, non-aqueous, liquid metal, and molten salt systems; thermal shock on systems and system components; and materials for target systems. Reliable data in these areas are crucial to the safe and reliable operation of new high-power facilities. These tests will provide data useful not only to spallation neutron sources proposed or under development, but also to other projects in accelerator-driven transmutation technologies such as the production of tritium.

  11. High yield neutron generator based on a high-current gasdynamic electron cyclotron resonance ion source

    NASA Astrophysics Data System (ADS)

    Skalyga, V.; Izotov, I.; Golubev, S.; Sidorov, A.; Razin, S.; Strelkov, A.; Tarvainen, O.; Koivisto, H.; Kalvas, T.

    2015-09-01

    In present paper, an approach for high yield compact D-D neutron generator based on a high current gasdynamic electron cyclotron resonance ion source is suggested. Results on dense pulsed deuteron beam production with current up to 500 mA and current density up to 750 mA/cm2 are demonstrated. Neutron yield from D2O and TiD2 targets was measured in case of its bombardment by pulsed 300 mA D+ beam with 45 keV energy. Neutron yield density at target surface of 109 s-1 cm-2 was detected with a system of two 3He proportional counters. Estimations based on obtained experimental results show that neutron yield from a high quality TiD2 target bombarded by D+ beam demonstrated in present work accelerated to 100 keV could reach 6 × 1010 s-1 cm-2. It is discussed that compact neutron generator with such characteristics could be perspective for a number of applications like boron neutron capture therapy, security systems based on neutron scanning, and neutronography.

  12. High yield neutron generator based on a high-current gasdynamic electron cyclotron resonance ion source

    SciTech Connect

    Skalyga, V.; Sidorov, A.; Izotov, I.; Golubev, S.; Razin, S.; Strelkov, A.; Tarvainen, O.; Koivisto, H.; Kalvas, T.

    2015-09-07

    In present paper, an approach for high yield compact D-D neutron generator based on a high current gasdynamic electron cyclotron resonance ion source is suggested. Results on dense pulsed deuteron beam production with current up to 500 mA and current density up to 750 mA/cm{sup 2} are demonstrated. Neutron yield from D{sub 2}O and TiD{sub 2} targets was measured in case of its bombardment by pulsed 300 mA D{sup +} beam with 45 keV energy. Neutron yield density at target surface of 10{sup 9} s{sup −1} cm{sup −2} was detected with a system of two {sup 3}He proportional counters. Estimations based on obtained experimental results show that neutron yield from a high quality TiD{sub 2} target bombarded by D{sup +} beam demonstrated in present work accelerated to 100 keV could reach 6 × 10{sup 10} s{sup −1} cm{sup −2}. It is discussed that compact neutron generator with such characteristics could be perspective for a number of applications like boron neutron capture therapy, security systems based on neutron scanning, and neutronography.

  13. Optimizing Moderator Dimensions for Neutron Scattering at the Spallation Neutron Source

    SciTech Connect

    Zhao, Jinkui; Robertson, Lee; Herwig, Kenneth W; Gallmeier, Franz X; Riemer, Bernie

    2013-01-01

    In this work, we investigate the effect of neutron moderator dimensions on the performance of neutron scattering instruments at the Spallation Neutron Source. In a recent study of the planned second target station at the Spallation Neutron Source (SNS) facility [1,2], we have found that the dimensions of a moderator play a significant role in determining its surface brightness. A smaller moderator may be significantly brighter for a smaller viewing area [4]. One of the immediate implications of this finding is that for modern neutron scattering instrument designs, moderator dimensions and brightness have to be incorporated as an integrated optimization parameter. Here, we establish a strategy of matching neutron scattering instruments with moderators using analytical and Monte Carlo techniques. In order to simplify our treatment, we group the instruments into two broad categories, those with natural collimation and those that use neutron guide systems. We found that the cross-sections of the sample and the neutron guide, respectively, are the deciding factors for choosing the moderator. Beam divergence plays no role as long as it is within the reach of practical constraints. Namely, the required divergence is not too large for the guide or sample to be located close enough to the moderator on an actual spallation source.

  14. Using a Tandem Pelletron accelerator to produce a thermal neutron beam for detector testing purposes.

    PubMed

    Irazola, L; Praena, J; Fernández, B; Macías, M; Bedogni, R; Terrón, J A; Sánchez-Nieto, B; Arias de Saavedra, F; Porras, I; Sánchez-Doblado, F

    2016-01-01

    Active thermal neutron detectors are used in a wide range of measuring devices in medicine, industry and research. For many applications, the long-term stability of these devices is crucial, so that very well controlled neutron fields are needed to perform calibrations and repeatability tests. A way to achieve such reference neutron fields, relying on a 3 MV Tandem Pelletron accelerator available at the CNA (Seville, Spain), is reported here. This paper shows thermal neutron field production and reproducibility characteristics over few days. PMID:26595777

  15. Pulsed neutrons: one year of experience with the new source at Argonne National Laboratory

    SciTech Connect

    Lander, G.H.

    1982-01-01

    The Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory is a spallation neutron source based on a 500-MeV proton accelerator operating at 30 Hz and with an average proton current of approx. 10 ..mu..A. Neutron-scattering instruments for elastic scattering include two powder diffractometers, a single-crystal diffractometer based on the Laue method and employing a large (30 x 30 cm) position-sensitive scintillation detector, a small-angle diffractometer using a position-sensitive detector, and a polarized-neutron diffractometer which will utilize the spin-refrigerator device to obtain a beam of white polarized neutrons. For inelastic scattering, we presently have the crystal-analyzer spectrometer and two chopper spectrometers capable of providing monoenergetic incident neutron beams of between 100 and 600 MeV. From its inception IPNS has been operating in a user mode and the selection of experiments is made by a Program Committee twice a year on the basis of the scientific merit of submitted proposals.

  16. Pulsed neutrons: One year of experience with the new source at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Lander, G. H.

    1983-05-01

    The Intense Pulsed Neutron Source (IPNS) at Argonne National Laboratory is a spallation neutron source based on a 500 MeV proton accelerator operating at 30 Hz and with an average proton current of ≈ 10 μA. Neutron scattering instruments for elastic scattering include two powder diffractometers, a single-crystal diffractometer based on the Laue method and employing a large (30 x 30 cm) position-sensitive scintillation detector, a small-angle diffractometer using a position-sensitive detector, and a polarized-neutron diffractometer which will utilize the spin-refrigerator device to obtain a beam of white polarized neutrons. For inelastic scattering we presently have the crystal-analyzer spectrometer, and two chopper spectrometers capable of providing monoenergetic incident neutron beams of between 100 and 600 meV. From its inception IPNS has been operating in a user mode and the selection of experiments is made by a Program Committee twice a year on the basis of the scientifi cmerit of submitted proposals.

  17. Ion-source and LEBT issues with the front-end systems for the Spallation Neutron Source

    SciTech Connect

    Keller, R.; Cheng, D.; DiGennaro, R.; Gough, R.A.; Greer, J.; Leung, K.N.; Ratti, A.; Reijonen, J.; Thomae, R.W.; Schenkel, T.; Staples, J.W.; Yourd, R.; Aleksandrov, A.; Stockli, M.P.; Welton, R.W.

    2001-09-01

    The Front-End Systems (FES) of the Spallation Neutron Source (SNS) project are being built by Berkeley Lab and will deliver a pulsed 40-mA H{sup -} ion beam at 2.5 MeV energy to the subsequent Drift-Tube Linac. The FES accelerator components comprise an rf driven, volume-production, cesium-enhanced, multi-cusp Ion Source; an electrostatic Low-Energy Beam Transport (LEBT) that includes provisions for transverse focusing, steering, and beam chopping; an RFQ accelerator; and a Medium-Energy Beam Transport (MEBT) line. The challenges for Ion Source and LEBT design are the generation of a plasma suitable for creating the required high H{sup -} ion density, lifetime of the rf antenna at 6% duty factor, removal of the parasitic electron population from the extracted negative ions, and emittance conservation. The paper discusses these issues in detail and highlights key experimental results obtained so far.

  18. Characteristics of a RF-Driven Ion Source for a Neutron Generator Used For Associated Particle Imaging

    SciTech Connect

    Wu, Ying; Hurley, John P.; Ji, Qing; Kwan, Joe; Leung, Ka-Ngo

    2008-08-08

    We present recent work on a prototype compact neutron generator for associated particle imaging (API). API uses alpha particles that are produced simultaneously with neutrons in the deuterium-tritium (2D(3T,n)4 alpha) fusion reaction to determine the direction of the neutrons upon exiting the reaction. This method determines the spatial position of each neutron interaction and requires the neutrons to be generated from a small spot in order to achieve high spatial resolution. The ion source for API is designed to produce a focused ion beam with a beam spot diameter of 1-mm or less on the target. We use an axial type neutron generator with a predicted neutron yield of 108 n/s for a 50 muA D/T ion beam current accelerated to 80 kV. The generator utilizes a RF planar spiral antenna at 13.56 MHz to create a highly efficient inductively-coupled plasma at the ion source. Experimental results show that beams with an atomic ion fraction of over 80percent can be obtained while utilizing only 100 watts of RF power in the ion source. A single acceleration gap with a secondary electron suppression electrode is used in the tube. Experimental results, such as the current density, atomic ion fraction, electron temperature, and electron density, from ion source testing will be discussed.

  19. Development of high-intensity D-D and D-T neutron sources and neutron filters for medical and industrial applications

    SciTech Connect

    Verbeke, J.M.

    2000-05-10

    This thesis consists of three main parts. The first one relates to boron neutron capture therapy. It summarizes the guidelines obtained by numerical simulations for the treatment of shallow and deep-seated brain tumors, as well as the results on the design of beam-shaping assemblies to moderate D-D and D-T neutrons to epithermal energies. The second part is about boron neutron capture synovectomy for the treatment of rheumatoid arthritis. Optimal neutron energy for treatment and beam-shaping assembly designs are summarized in this section. The last part is on the development of the sealed neutron generator, including experimental results on the prototype ion source and the prototype accelerator column.

  20. The sciences and applications of the Electron LINAC-driven neutron source in Argentina

    NASA Astrophysics Data System (ADS)

    Granada, J. R.; Mayer, R. E.; Dawidowski, J.; Santisteban, J. R.; Cantargi, F.; Blostein, J. J.; Rodríguez Palomino, L. A.; Tartaglione, A.

    2016-06-01

    The Neutron Physics group at Centro Atómico Bariloche (CNEA, Argentina) has evolved for more than forty five years around a small 25MeV linear electron accelerator. It constitutes our compact accelerator-driven neutron source (CANS), which is dedicated to the use and development of neutronic methods to tackle problems of basic sciences and technological applications. Its historical first commitment has been the determination of the total cross sections of materials as a function of neutron energy by means of transmission experiments for thermal and sub-thermal neutrons. This also allowed testing theoretical models for the generation of scattering kernels and cross sections. Through the years, our interests moved from classic pulsed neutron diffraction, which included the development of high-precision methods for the determination of very low hydrogen content in metals, towards deep inelastic neutron scattering (DINS), a powerful tool for the determination of atomic momentum distribution in condensed matter. More recently non-intrusive techniques aimed at the scanning of large cargo containers have started to be developed with our CANS, testing the capacity and limitations to detect special nuclear material and dangerous substances. Also, the ever-present "bremsstrahlung" radiation has been recognized and tested as a useful complement to instrumental neutron activation, as it permits to detect other nuclear species through high-energy photon activation. The facility is also used for graduate and undergraduate students' experimental work within the frame of Instituto Balseiro Physics and Nuclear Engineering courses of study, and also MSc and PhD theses work.

  1. Plans for an Ultra Cold Neutron source at Los Alamos

    SciTech Connect

    Seestrom, S.J.; Bowles, T.J.; Hill, R.; Greene, G.L.

    1996-10-01

    Ultra Cold Neutrons (UCN) can be produced at spallation sources using a variety of techniques. To date the technique used has been to Bragg scatter and Doppler shift cold neutrons into UCN from a moving crystal. This is particularly applicable to short-pulse spallation sources. We are presently constructing a UCN source at LANSCE using this method. In addition, large gains in UCN density should be possible using cryogenic UCN sources. Research is under way at Gatchina to demonstrate technical feasibility of a frozen deuterium source. If successful, a source of this type could be implemented at future spallation source, such as the long pulse source being planned at Los Alamos, with a UCN density that may be two orders of magnitude higher than that presently available at reactors.

  2. Development of an ultra cold neutron source at MLNSC

    SciTech Connect

    Seestrom, S.J.; Bowles, T.J.; Hill, R.; Greene, G.L.; Morris, C.L.

    1996-09-01

    Ultra Cold Neutrons (UCN) can be produced at spallation sources using a variety of techniques. To date the technique used has been to Bragg scatter and Doppler shift cold neutrons into UCN from a moving crystal. This is particularly applicable to short-pulse spallation sources. We are presently constructing a UCN source at LANSCE using this method. In addition, large gains in UCN density should be possible using cryogenic UCN sources. Research is under way at Gatchina to demonstrate technical feasibility of a frozen deuterium source. If successful, a source of this type could be implemented at future spallation sources, such as the long pulse source being planned at Los Alamos, with a UCN density that may be two orders of magnitude higher than that presently available at reactors.

  3. Core Vessel Insert Handling Robot for the Spallation Neutron Source

    SciTech Connect

    Graves, Van B; Dayton, Michael J

    2011-01-01

    The Spallation Neutron Source provides the world's most intense pulsed neutron beams for scientific research and industrial development. Its eighteen neutron beam lines will eventually support up to twenty-four simultaneous experiments. Each beam line consists of various optical components which guide the neutrons to a particular instrument. The optical components nearest the neutron moderators are the core vessel inserts. Located approximately 9 m below the high bay floor, these inserts are bolted to the core vessel chamber and are part of the vacuum boundary. They are in a highly radioactive environment and must periodically be replaced. During initial SNS construction, four of the beam lines received Core Vessel Insert plugs rather than functional inserts. Remote replacement of the first Core Vessel Insert plug was recently completed using several pieces of custom-designed tooling, including a highly complicated Core Vessel Insert Robot. The design of this tool are discussed.

  4. Neutron-source characterization for fusion-materials studies

    SciTech Connect

    Greenwood, L.R.

    1981-06-01

    Neutron-flux and energy-spectrum measurements are conducted for all major fusion-materials irradiation facilities, including fission reactors and accelerators. Dosimetry-characterization experiments and integral cross section measurements have been performed. Multiple activation and helium-production measurements are performed routinely to provide materials experimenters with neutron-exposure parameters including fluence, spectrum, displacements, gas production, and transmutation with typical accuracies of 10 to 15%. Such data are crucial to the fusion-materials program in order to correlate materials-property changes between irradiations and facilities and to confidently predict the performance of materials in fusion reactors.

  5. A dual neutron/gamma source for the Fissmat Inspection for Nuclear Detection (FIND) system.

    SciTech Connect

    Doyle, Barney Lee; King, Michael; Rossi, Paolo; McDaniel, Floyd Del; Morse, Daniel Henry; Antolak, Arlyn J.; Provencio, Paula Polyak; Raber, Thomas N.

    2008-12-01

    Shielded special nuclear material (SNM) is very difficult to detect and new technologies are needed to clear alarms and verify the presence of SNM. High-energy photons and neutrons can be used to actively interrogate for heavily shielded SNM, such as highly enriched uranium (HEU), since neutrons can penetrate gamma-ray shielding and gamma-rays can penetrate neutron shielding. Both source particles then induce unique detectable signals from fission. In this LDRD, we explored a new type of interrogation source that uses low-energy proton- or deuteron-induced nuclear reactions to generate high fluxes of mono-energetic gammas or neutrons. Accelerator-based experiments, computational studies, and prototype source tests were performed to obtain a better understanding of (1) the flux requirements, (2) fission-induced signals, background, and interferences, and (3) operational performance of the source. The results of this research led to the development and testing of an axial-type gamma tube source and the design/construction of a high power coaxial-type gamma generator based on the {sup 11}B(p,{gamma}){sup 12}C nuclear reaction.

  6. H{sup -} radio frequency source development at the Spallation Neutron Source

    SciTech Connect

    Welton, R. F.; Gawne, K. R.; Han, B. X.; Murray, S. N.; Pennisi, T. R.; Roseberry, R. T.; Santana, M.; Stockli, M. P.; Dudnikov, V. G.; Turvey, M. W.

    2012-02-15

    The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. H{sup -} beam pulses ({approx}1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, {approx}60 kW) of a copper antenna that has been encased with a thickness of {approx}0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of {approx}99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of {approx}75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance/installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to {approx}100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

  7. Neutron field measurements for alara purposes around a Van de Graaff accelerator building.

    PubMed

    Kockerols, P; Lebacq, A L; Gasparro, J; Hult, M; Janssens, H; Lövestam, G; Vanhavere, F

    2004-01-01

    The Institute for Reference Materials and Measurements operates a 7.0 MV Van de Graaff accelerator to generate monoenergetic neutron radiation for experimental applications. Owing to increased intensities of generated neutron fields and the more stringent regulation related to the maximum dose for the public, a concrete shielding wall surrounding the experimental building was constructed. This paper presents a study aiming at evaluating the effect of the shielding on the neutron field outside the wall. For this purpose, the following measurements were carried out around the building: (1) cartography of the neutron field for different experimental conditions; (2) measurement of neutron spectra using multiple Bonner spheres; (3) activation measurements using gold discs followed by low-level gamma spectrometry. From the measurements, it can be concluded that the wall fulfils its purpose to reduce the neutron dose rate to the surrounding area to an acceptable level. PMID:15353736

  8. Spent-fuel photon and neutron source spectra

    SciTech Connect

    Hermann, O.W.; Alexander, C.W.

    1983-01-01

    Computational activities at Oak Ridge National Laboratory have been performed to develop appropriate data and techniques for computing the photon and neutron source spectra of spent fuel. The methods reviewed here include both the determination of spent-fuel composition and the radiation source spectra associated with these isotopic inventories.

  9. Neutron and gamma-ray signatures for particle acceleration in solar flares

    NASA Technical Reports Server (NTRS)

    Ramaty, R.; Murphy, R. J.

    1984-01-01

    The production of neutrons, 4 to 7 MeW nuclear gamma rays, positrons and pions resulting from the interaction of flare accelerated particles with the solar atmosphere was calculated. For the energy spectra of these particles the Bessel function predicted by stochastic acceleration and power laws which could result from acceleration at large-scale planar shocks was used, with the thick-target model. It is assumed that in the interaction region the accelerated particles are isotropic. The neutron-to-2.223 MeV photon conversion factors for various flare locations on the Sun are derived by averaging conversion factors over these spectra. Comparing calculations with data confirms that for most gamma-ray flares the bulk of the accelerated particles remain trapped at the Sun and that these particles have spectra similar to the spectra of flare particles observed in interplanetary space.

  10. Saturn Neutron Exosphere as Source for Inner and Innermost Radiation Belts

    NASA Technical Reports Server (NTRS)

    Cooper, John; Lipatov, Alexander; Sittler, Edward; Sturner, Steven

    2011-01-01

    Energetic proton and electron measurements by the ongoing Cassini orbiter mission are expanding our knowledge of the highest energy components of the Saturn magnetosphere in the inner radiation belt region after the initial discoveries of these belts by the Pioneer 11 and Voyager 2 missions. Saturn has a neutron exosphere that extends throughout the magnetosphere from the cosmic ray albedo neutron source at the planetary main rings and atmosphere. The neutrons emitted from these sources at energies respectively above 4 and 8 eV escape the Saturn system, while those at lower energies are gravitationally bound. The neutrons undergo beta decay in average times of about 1000 seconds to provide distributed sources of protons and electrons throughout Saturn's magnetosphere with highest injection rates close to the Saturn and ring sources. The competing radiation belt source for energetic electrons is rapid inward diffusion and acceleration of electrons from the middle magnetosphere and beyond. Minimal losses during diffusive transport across the moon orbits, e.g. of Mimas and Enceladus, and local time asymmetries in electron intensity, suggest that drift resonance effects preferentially boost the diffusion rates of electrons from both sources. Energy dependences of longitudinal gradient-curvature drift speeds relative to the icy moons are likely responsible for hemispheric differences (e.g., Mimas, Tethys) in composition and thermal properties as at least partly produced by radiolytic processes. A continuing mystery is the similar radial profiles of lower energy (<10 MeV) protons in the inner belt region. Either the source of these lower energy protons is also neutron decay, but perhaps alternatively from atmospheric albedo, or else all protons from diverse distributed sources are similarly affected by losses at the moon' orbits, e.g. because the proton diffusion rates are extremely low. Enceladus cryovolcanism, and radiolytic processing elsewhere on the icy moon and

  11. THE COMMISSIONING PLAN FOR THE SPALLATION NEUTRON SOURCE RING AND TRANSPORT LINES.

    SciTech Connect

    RAPARIA,D.BLASKIEWICZ,M.LEE,Y.Y.WEI,J.ET AL.

    2004-03-10

    The Spallation Neutron Source (SNS) accelerator systems will provide a 1 GeV, 1.44 MW proton beam to a liquid mercury target for neutron production. In order to satisfy the accelerator systems' portion of the Critical Decision 4 (CD-4) commissioning goal (which marks the completion of the construction phase of the project), a beam pulse with intensity greater than 1 x 10{sup 13} protons must be accumulated in the ring, extracted in a single turn and delivered to the target. A commissioning plan has been formulated for bringing into operation and establishing nominal operating conditions for the various ring and transport line subsystems as well as for establishing beam conditions and parameters which meet the commissioning goal.

  12. Separation of beam and electrons in the spallation neutron source H{sup -} ion source

    SciTech Connect

    Whealton, J.H.; Raridon, R.J.; Leung, K.N.

    1997-12-01

    The Spallation Neutron Source (SNS) requires an ion source producing an H{sup {minus}} beam with a peak current of 35mA at a 6.2 percent duty factor. For the design of this ion source, extracted electrons must be transported and dumped without adversely affecting the H{sup {minus}} beam optics. Two issues are considered: (1) electron containment transport and controlled removal; and (2) first-order H{sup {minus}} beam steering. For electron containment, various magnetic, geometric and electrode biasing configurations are analyzed. A kinetic description for the negative ions and electrons is employed with self-consistent fields obtained from a steady-state solution to Poisson`s equation. Guiding center electron trajectories are used when the gyroradius is sufficiently small. The magnetic fields used to control the transport of the electrons and the asymmetric sheath produced by the gyrating electrons steer the ion beam. Scenarios for correcting this steering by split acceleration and focusing electrodes will be considered in some detail.

  13. Design considerations for neutron activation and neutron source strength monitors for ITER

    SciTech Connect

    Barnes, C.W.; Jassby, D.L.; LeMunyan, G.; Roquemore, A.L.; Walker, C.

    1997-12-31

    The International Thermonuclear Experimental Reactor will require highly accurate measurements of fusion power production in time, space, and energy. Spectrometers in the neutron camera could do it all, but experience has taught us that multiple methods with redundancy and complementary uncertainties are needed. Previously, conceptual designs have been presented for time-integrated neutron activation and time-dependent neutron source strength monitors, both of which will be important parts of the integrated suite of neutron diagnostics for this purpose. The primary goals of the neutron activation system are: to maintain a robust relative measure of fusion energy production with stability and wide dynamic range; to enable an accurate absolute calibration of fusion power using neutronic techniques as successfully demonstrated on JET and TFTR; and to provide a flexible system for materials testing. The greatest difficulty is that the irradiation locations need to be close to plasma with a wide field of view. The routing of the pneumatic system is difficult because of minimum radius of curvature requirements and because of the careful need for containment of the tritium and activated air. The neutron source strength system needs to provide real-time source strength vs. time with {approximately}1 ms resolution and wide dynamic range in a robust and reliable manner with the capability to be absolutely calibrated by in-situ neutron sources as done on TFTR, JT-60U, and JET. In this paper a more detailed look at the expected neutron flux field around ITER is folded into a more complete design of the fission chamber system.

  14. Surface-plasma negative ion source for the medicine accelerator (abstract)

    NASA Astrophysics Data System (ADS)

    Belchenko, Y. I.; Grigoryev, E. V.

    2002-02-01

    A neutron source for boron capture neutron therapy is under development at the Budker Institute of Nuclear Physics (BINP). It is based on a tandem vacuum-isolated accelerator using a dc negative hydrogen ion source. A compact dc ion source model having reliable operation and simplified maintenance was developed at BINP as a prototype of the high current source for the medicine accelerator. The compact model (CM) uses a glow discharge with modified Penning geometry of the electrodes and explores surface-plasma negative ion (NI) production on the cesiated anode surface. The CM optimal parameters are as follows: discharge voltage 60-80 V, discharge current up to 6 A, hydrogen pressure 4-5 Pa, cesium consumption <1 mg/h, transverse magnetic field 0.5-1 kG s, optimal anode temperature 250-350 °C. A built-in heater provides the CM a quick start and simplifies CM electrode conditioning. The CM delivers a NI beam with a current of 5 mA, beam energy of 17 keV, normalized emittance of about 0.3 π mm mrad and an emission current density of about 0.1 A/cm2. NI beam current is directly proportional to the discharge current and to the emission hole area. The CM quick start and stable dc operation for several hour runs were multiply tested. No essential erosion of electrodes was recorded.

  15. Neutron source reconstruction from pinhole imaging at National Ignition Facility.

    PubMed

    Volegov, P; Danly, C R; Fittinghoff, D N; Grim, G P; Guler, N; Izumi, N; Ma, T; Merrill, F E; Warrick, A L; Wilde, C H; Wilson, D C

    2014-02-01

    The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the ignition stage of inertial confinement fusion (ICF) implosions at NIF. Since the neutron source is small (∼100 μm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-μm resolution are 20-cm long, single-sided tapers in gold. These apertures, which have triangular cross sections, produce distortions in the image, and the extended nature of the pinhole results in a non-stationary or spatially varying point spread function across the pinhole field of view. In this work, we have used iterative Maximum Likelihood techniques to remove the non-stationary distortions introduced by the aperture to reconstruct the underlying neutron source distributions. We present the detailed algorithms used for these reconstructions, the stopping criteria used and reconstructed sources from data collected at NIF with a discussion of the neutron imaging performance in light of other diagnostics. PMID:24593362

  16. Neutron source reconstruction from pinhole imaging at National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Volegov, P.; Danly, C. R.; Fittinghoff, D. N.; Grim, G. P.; Guler, N.; Izumi, N.; Ma, T.; Merrill, F. E.; Warrick, A. L.; Wilde, C. H.; Wilson, D. C.

    2014-02-01

    The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the ignition stage of inertial confinement fusion (ICF) implosions at NIF. Since the neutron source is small (˜100 μm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-μm resolution are 20-cm long, single-sided tapers in gold. These apertures, which have triangular cross sections, produce distortions in the image, and the extended nature of the pinhole results in a non-stationary or spatially varying point spread function across the pinhole field of view. In this work, we have used iterative Maximum Likelihood techniques to remove the non-stationary distortions introduced by the aperture to reconstruct the underlying neutron source distributions. We present the detailed algorithms used for these reconstructions, the stopping criteria used and reconstructed sources from data collected at NIF with a discussion of the neutron imaging performance in light of other diagnostics.

  17. Neutron source reconstruction from pinhole imaging at National Ignition Facility

    SciTech Connect

    Volegov, P.; Danly, C. R.; Grim, G. P.; Guler, N.; Merrill, F. E.; Wilde, C. H.; Wilson, D. C.; Fittinghoff, D. N.; Izumi, N.; Ma, T.; Warrick, A. L.

    2014-02-15

    The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the ignition stage of inertial confinement fusion (ICF) implosions at NIF. Since the neutron source is small (∼100 μm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-μm resolution are 20-cm long, single-sided tapers in gold. These apertures, which have triangular cross sections, produce distortions in the image, and the extended nature of the pinhole results in a non-stationary or spatially varying point spread function across the pinhole field of view. In this work, we have used iterative Maximum Likelihood techniques to remove the non-stationary distortions introduced by the aperture to reconstruct the underlying neutron source distributions. We present the detailed algorithms used for these reconstructions, the stopping criteria used and reconstructed sources from data collected at NIF with a discussion of the neutron imaging performance in light of other diagnostics.

  18. Feasibility of sealed D-T neutron generator as neutron source for liver BNCT and its beam shaping assembly.

    PubMed

    Liu, Zheng; Li, Gang; Liu, Linmao

    2014-04-01

    This paper involves the feasibility of boron neutron capture therapy (BNCT) for liver tumor with four sealed neutron generators as neutron source. Two generators are placed on each side of the liver. The high energy of these emitted neutrons should be reduced by designing a beam shaping assembly (BSA) to make them useable for BNCT. However, the neutron flux decreases as neutrons pass through different materials of BSA. Therefore, it is essential to find ways to increase the neutron flux. In this paper, the feasibility of using low enrichment uranium as a neutron multiplier is investigated to increase the number of neutrons emitted from D-T neutron generators. The neutron spectrum related to our system has a proper epithermal flux, and the fast and thermal neutron fluxes comply with the IAEA recommended values. PMID:24448270

  19. 14-MeV Neutron Generator Used as a Thermal Neutron Source

    SciTech Connect

    Dioszegi,I.

    2008-08-10

    One of the most important applications of the general purpose Monte Carlo N-Particle (MCNPS and MCNPX) codes is neutron shielding design. We employed this method to simulate the shield of a 14-MeV neutron generator used as a thermal neutron source providing an external thermal neutron beam for testing large area neutron detectors developed for diffraction studies in biology and also useful for national security applications. Nuclear reactors have been the main sources of neutrons used for scientific applications. In the past decade, however, a large number of reactors have been shut down, and the importance of other, smaller devices capable of providing neutrons for research has increased. At Brookhaven National Laboratory a moderated Am-Be neutron source with shielding is used for neutron detector testing. This source is relatively weak, but provides a constant flux of neutrons, even when not in use. The use of a 14 MeV energized neutron generator, with an order of magnitude higher neutron flux has been considered to replace the Am-Be source, but the higher fast neutron yield requires a more careful design of moderator and shielding. In the present paper we describe a proposed shielding configuration based on Monte Carlo calculations, and provide calculated neutron flux and dose distributions. We simulated the neutron flux distribution of our existing Am-Be source surrounded by a paraffin thermalizer cylinder (radius of 17.8 cm), 0.8 mm cadmium, and borated polyethylene as biological shield. The thermal neutrons are available through a large opening through the polyethylene and cadmium. The geometrical model for the MCNPS and MCNPX2 simulations is shown in Fig. 1. We simulated the Am-Be source neutron energy distribution as a point source having an energy distribution of four discrete lines at 3.0 (37%), 5.0 (35%), 8.0 (20%) and 11.0 (8%) MeV energies. The estimated source strength based on the original specifications is 6.6 {center_dot} 10{sup 6} neutrons

  20. Accelerator-Based Biological Irradiation Facility Simulating Neutron Exposure from an Improvised Nuclear Device.

    PubMed

    Xu, Yanping; Randers-Pehrson, Gerhard; Turner, Helen C; Marino, Stephen A; Geard, Charles R; Brenner, David J; Garty, Guy

    2015-10-01

    We describe here an accelerator-based neutron irradiation facility, intended to expose blood or small animals to neutron fields mimicking those from an improvised nuclear device at relevant distances from the epicenter. Neutrons are generated by a mixed proton/deuteron beam on a thick beryllium target, generating a broad spectrum of neutron energies that match those estimated for the Hiroshima bomb at 1.5 km from ground zero. This spectrum, dominated by neutron energies between 0.2 and 9 MeV, is significantly different from the standard reactor fission spectrum, as the initial bomb spectrum changes when the neutrons are transported through air. The neutron and gamma dose rates were measured using a custom tissue-equivalent gas ionization chamber and a compensated Geiger-Mueller dosimeter, respectively. Neutron spectra were evaluated by unfolding measurements using a proton-recoil proportional counter and a liquid scintillator detector. As an illustration of the potential use of this facility we present micronucleus yields in single divided, cytokinesis-blocked human peripheral lymphocytes up to 1.5 Gy demonstrating 3- to 5-fold enhancement over equivalent X-ray doses. This facility is currently in routine use, irradiating both mice and human blood samples for evaluation of neutron-specific biodosimetry assays. Future studies will focus on dose reconstruction in realistic mixed neutron/photon fields. PMID:26414507

  1. The new cold neutron chopper spectrometer at the Spallation Neutron Source: design and performance.

    PubMed

    Ehlers, G; Podlesnyak, A A; Niedziela, J L; Iverson, E B; Sokol, P E

    2011-08-01

    The design and performance of the new cold neutron chopper spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct-geometry inelastic time-of-flight spectrometer, designed essentially to cover the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM-II, AMATERAS at J-PARC, PHAROS at LANSCE, and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments. PMID:21895276

  2. The new cold neutron chopper spectrometer at the Spallation Neutron Source: Design and performance

    SciTech Connect

    Ehlers, G.; Podlesnyak, A. A.; Niedziela, J. L.; Iverson, E. B.; Sokol, P. E.

    2011-08-15

    The design and performance of the new cold neutron chopper spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct-geometry inelastic time-of-flight spectrometer, designed essentially to cover the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM-II, AMATERAS at J-PARC, PHAROS at LANSCE, and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments.

  3. The new Cold Neutron Chopper Spectrometer at the Spallation Neutron Source -- Design and Performance

    SciTech Connect

    Ehlers, Georg; Podlesnyak, Andrey A.; Niedziela, Jennifer L.; Iverson, Erik B.; Sokol, Paul E.

    2011-01-01

    The design and performance of the new cold neutron chopper spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct-geometry inelastic time-of-flight spectrometer, designed essentially to cover the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM-II, AMATERAS at J-PARC, PHAROS at LANSCE, and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments.

  4. Comparison of fission neutron and pulsed spallation neutron sources for radiation effects experiments on Cu/sub 3/Au

    SciTech Connect

    Kirk, M.A.

    1983-10-01

    Through our recent experimental work on the neutron irradiation effects in Cu/sub 3/Au, we will compare fission and pulsed spallation neutron sources. Neutron characteristics of irradiation facilities at the Intense Pulsed Neutron Source (IPNS) and the CP-5 reactor (now closed down), are briefly described. Defect cascade size distributions from irradiations of Cu/sub 3/Au at both neutron sources illustrated by transmission electron micrographs of disordered zones. Radiation-enhanced diffusion experiments in Cu/sub 3/Au are discussed along with the effect of pulsed neutron irradiations.

  5. Flexible magnetic design of the MITICA plasma source and accelerator

    NASA Astrophysics Data System (ADS)

    Chitarin, G.; Marconato, N.; Agostinetti, P.; Serianni, G.; Sonato, P.

    2013-02-01

    MITICA is a negative-Ion-based 1 MeV Neutral Beam Injector. The transverse magnetic field in the plasma source and in the accelerator are crucial for preventing the electrons in the plasma source from entering the accelerator and deflecting the secondary electrons, generated inside the accelerator by stripping reactions with background gas, before they are accelerated at higher energy. The scientific objective of MITICA is essentially the experimental validation of the ITER 1 MeV Neutral Beam injector design and indeed a flexible solution is necessary in order to allow an independent variation of the magnetic field in the plasma source and in the accelerator during the experimental campaign. To this purpose a specific magnetic design has been developed and optimized, essentially based on current-carrying busbars with the possible addition of external coils or magnets. The validated magnetic field configuration will then be replicated in the ITER HNB, using only a current-carrying busbar system. The paper presents the rationale of the various steps of this process and the final design obtained.

  6. Neutron energy spectrum characterization on TMR-1 at the Indiana University neutron source

    NASA Astrophysics Data System (ADS)

    Halstead, Matthew R.; Lee, Sangjin; Petrosky, James; Bickley, Abigail; Sokol, Paul

    The energy spectrum of the Neutron Radiation Effects Program (NREP) beam line, Target-Moderator-Reflector-1 (TMR-1), at Indiana University has not been previously characterized. The facility has a unique proton source with variable pulse length (15-600 ms) and energy (13 MeV). Thus, it can produce a unique and tailored neutron beam when incident on a beryllium target. Through a combination of MCNP-X particle simulations, neutron activation experiments, and application of a spectrum unfolding code (SAND-II), the neutron source is characterized. Eight activation foils and wires were irradiated in the target area and the gamma activity measured. This information was used in an unfolding code, SAND-II, to deconvolve the spectrum, using the MCNP simulations as a basis for the spectral fitting.

  7. High-flux source of fusion neutrons for material and component testing

    SciTech Connect

    Baldwin, D. E.; Hooper, E. B.; Ryutov, D. D.; Thomassen, K. I.

    1999-01-07

    The inner part of a fusion reactor will have to operate at very high neutron loads. In steady-state reactors the minimum fluence before the scheduled replacement of the reactor core should be at least l0-15 Mw.yr/m2. A more frequent replacement of the core is hardly compatible with economic constraints. A most recent summary of the discussions of these issues is presented in Ref. [l]. If and when times come to build a commercial fusion reactor, the availability of information on the behavior of materials and components at such fluences will become mandatory for making a final decision. This makes it necessary an early development and construction of a neutron source for fusion material and component testing. In this paper, we present information on one very attractive concept of such a source: a source based on a so called Gas Dynamic Trap. This neutron source was proposed in the mid 1980s (Ref. [2]; see also a survey [3] with discussion of the early stage of the project). Since then, gradual accumulation of the relevant experimental information on a modest-scale experimental facility GDT at Novosibirsk, together with a continuing design activity, have made initial theoretical considerations much more credible. We believe that such a source can be built within 4 or 5 years. Of course, one should remember that there is a chance for developing steady-state reactors with a liquid (and therefore continuously renewable) first wall [4], which would also serve as a tritium breeder. In this case, the need in the neutron testing will become less pressing. However, it is not clear yet that the concept of the flowing wall will be compatible with all types of steady-state reactors. It seems therefore prudent to be prepared to the need of a quick construction of a neutron source. It should also be mentioned that there exist projects of the accelerator-based neutron sources (e.g., [5]). However, they generally have two major disadvantages: a wrong neutron spectrum

  8. Accelerator mass spectrometry of 36Cl produced by neutrons from the Hiroshima bomb.

    PubMed

    Kato, K; Habara, M; Yoshizawa, Y; Biebel, U; Haberstock, G; Heinzl, J; Korschinek, G; Morinaga, H; Nolte, E

    1990-10-01

    Accelerator mass spectrometry was performed at the Munich tandem laboratory to determine 36Cl/Cl ratios of samples from a tombstone exposed to neutrons from the Hiroshima bomb. The ratios were determined from the surface to deeper positions. The depth profile of 36Cl/Cl can be used for estimating the neutron energy distribution and intensity near the hypocentre in Hiroshima. PMID:1976726

  9. Monte Carlo Simulations of the Response of Shielded SNM to a Pulsed Neutron Source

    SciTech Connect

    E.H. Seabury; D.L. Chichester

    2010-08-01

    Active interrogation (AI) has been used as a technique for the detection and identification of Special Nuclear Material (SNM) for both proposed and field-tested systems. Idaho National Laboratory (INL) has been studying this technique for systems ranging from small systems employing portable electronic neutron generators (ENGs) 1 to larger systems employing linear accelerators as high-energy photon sources for assessment of vehicles and cargo2. In order to assess the feasibility of new systems, INL has undertaken a campaign of Monte Carlo simulations of the response of a variety of masses of SNM in multiple shielding configurations to a pulsed neutron source using the MCNPX3 code, with emphasis on the neutron and photon response of the system as a function of time after the initial neutron pulse. We present here some preliminary results from these calculations. 1. D.L. Chichester and E.H. Seabury, “ Using Electronic Neutron Generators in Active Interrogation to Detect Shielded Nuclear Material,” IEEE Transactions on Nuclear Science 56 (2009) pp 441-447. 2. J.L. Jones et al., “Photonuclear-based, nuclear material detection system for cargo containers,” Nuclear Instruments and Methods in Physics Research B 241 (2005) pp 770-776. 3. D.B. Pelowitz, “MCNPXTM User’s Manual version 2.6.0,” Los Alamos National Laboratory Report LA-CP-07-1473 (2008).

  10. Study of neutron focusing at the Texas Cold Neutron Source. Final report

    SciTech Connect

    Wehring, B.W.; Uenlue, K.

    1995-03-06

    Funds were received for the first year of a three year DOE Nuclear Engineering Research Grant, ``Study of Neutron Focusing at the Texas Cold Neutron Source`` (FGO2-92ER75711). The purpose of this three year study was to develop a neutron focusing system to be used with the Texas Cold Neutron Source (TCNS) to produce an intense beam of neutrons. A prompt gamma activation analysis (PGAA) facility was also to be designed, setup, and tested under the three year project. During the first year of the DOE grant, a new procedure was developed and used to design a focusing converging guide consisting of truncated rectangular cone sections. Detailed calculations were performed using a 3-D Monte Carlo code which we wrote to trace neutrons through the curved guide of the TCNS into the proposed converging guide. Using realistic reflectivities for Ni-Ti supermirrors, we obtained gains of 3 to 5 for the neutron flux averaged over an area of 1 {times} 1 cm.

  11. Status of the Advanced Photon Source (APS) linear accelerator

    SciTech Connect

    White, M.; Berg, W.; Fuja, R.; Grelick, A.; Mavrogenes, G.; Nassiri, A.; Russell, T.; Wesolowski, W.

    1993-08-01

    A 2856-MHz S-band, 450-MeV electron/positron linear accelerator is the first part of the injector for the Advanced Photon Source (APS) 7-GeV storage ring. Construction of the APS linac is currently nearing completion, and commissioning will begin in July 1993. The linac and its current status are discussed in this paper.

  12. Development and Characterization of Pulsed Neutron Sources at NTF

    NASA Astrophysics Data System (ADS)

    McKee, Erik; Hammel, Ben; Lowe, Danny; Presura, Radu; Ivanov, Vladimir; Haque, Showera; Covington, Aaron; Iratcabal, Jeremy; McCormick, Zephyr; Darling, Tim; NTF Team; Nevada Security Technologies, LLC Collaboration

    2015-11-01

    Short duration, high-intensity pulsed neutron sources are being developed on the Zebra 1-MA/100ns pulsed-power generator. Ion beam collisions above threshold energies in a Z-pinch containing deuterium are the primary production mechanism of the 2.45 MeV neutrons. Deuterium treated palladium wire-arrays have been successfully used to produce neutrons on Zebra, but the deuterium content of the Pd wire storage diminishes rapidly. More traditional single-shell gas puffs have also been designed and implemented and allow for much higher repetition rates and ability to control the load composition; both pure deuterium and binary mixtures of krypton and deuterium gases were used. Both sources are capable of producing 1e10 neutrons per pulse. The yield and spectrum of the neutron pulse was measured by a combination of Ag and Y activation detectors and time-of-flight scintillator-PMT detectors. A model of the experimental area was used in the MCNP code to determine the scattering contribution and assist in calibration of the neutron detectors. Support for this work is provided by DOE/NNSA grant DE-NA0002075.

  13. The experimental program at the WNR neutron source at LAMPF

    SciTech Connect

    Lisowski, P.W.

    1991-01-01

    There are two white neutron sources at Los Alamos National Laboratory which are used in broad scientific program over the energy range from thermal to about seven hundred MeV. Largely because of the increased intensity over such an unprecedented energy range, use of these two facilities for nuclear science research has grown from 36 experimenters in 1987 to 118 in 1990. This paper focuses on research underway or recently completed at the high-energy neutron source of the WNR facility. 18 refs., 6 figs.

  14. Detection of supernova neutrinos at spallation neutron sources

    NASA Astrophysics Data System (ADS)

    Huang, Ming-Yang; Guo, Xin-Heng; Young, Bing-Lin

    2016-07-01

    After considering supernova shock effects, Mikheyev-Smirnov-Wolfenstein effects, neutrino collective effects, and Earth matter effects, the detection of supernova neutrinos at the China Spallation Neutron Source is studied and the expected numbers of different flavor supernova neutrinos observed through various reaction channels are calculated with the neutrino energy spectra described by the Fermi-Dirac distribution and the “beta fit” distribution respectively. Furthermore, the numerical calculation method of supernova neutrino detection on Earth is applied to some other spallation neutron sources, and the total expected numbers of supernova neutrinos observed through different reactions channels are given. Supported by National Natural Science Foundation of China (11205185, 11175020, 11275025, 11575023)

  15. First experimental results from 2 MeV proton tandem accelerator for neutron production.

    PubMed

    Kudryavtsev, A; Belchenko, Yu; Burdakov, A; Davydenko, V; Ivanov, A; Khilchenko, A; Konstantinov, S; Krivenko, A; Kuznetsov, A; Mekler, K; Sanin, A; Shirokov, V; Sorokin, I; Sulyaev, Yu; Tiunov, M

    2008-02-01

    A 2 MeV proton tandem accelerator with vacuum insulation was developed and first experiments are carried out in the Budker Institute of Nuclear Physics (Novosibirsk). The accelerator is designed for neutron production via reaction (7)Li(p,n)(7)Be for the boron neutron-capture therapy of the brain tumors, and for explosive detection based on 9.1724 MeV resonance gamma, which are produced via reaction (13)C(p,gamma)(14)N, absorption in nitrogen. PMID:18315262

  16. First experimental results from 2 MeV proton tandem accelerator for neutron production

    SciTech Connect

    Kudryavtsev, A.; Belchenko, Yu.; Burdakov, A.; Davydenko, V.; Ivanov, A.; Khilchenko, A.; Konstantinov, S.; Krivenko, A.; Kuznetsov, A.; Mekler, K.; Sanin, A.; Shirokov, V.; Sorokin, I.; Sulyaev, Yu.; Tiunov, M.

    2008-02-15

    A 2 MeV proton tandem accelerator with vacuum insulation was developed and first experiments are carried out in the Budker Institute of Nuclear Physics (Novosibirsk). The accelerator is designed for neutron production via reaction {sup 7}Li(p,n){sup 7}Be for the boron neutron-capture therapy of the brain tumors, and for explosive detection based on 9.1724 MeV resonance gamma, which are produced via reaction {sup 13}C(p,{gamma}){sup 14}N, absorption in nitrogen.

  17. Tandem-ESQ for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT)

    SciTech Connect

    Kreiner, A. J.; Kwan, J. W.; Henestroza, E.; Burlon, A. A.; Di Paolo, H.; Minsky, D.; Debray, M.; Valda, A.; Somacal, H. R.

    2007-02-12

    A folded tandem, with 1.25 MV terminal voltage, combined with an ElectroStatic Quadrupole (ESQ) chain is being proposed as a machine for Accelerator-Based Boron Neutron Capture Therapy (AB-BNCT). The machine is shown to be capable of accelerating a 30 mA proton beam to 2.5 MeV. These are the specifications needed to produce sufficiently intense and clean epithermal neutron beams, based on the on the 7Li(p,n)7Be reaction, to perform BNCT treatment for deep seated tumors in less than an hour.

  18. Improvements to the internal and external antenna H{sup −} ion sources at the Spallation Neutron Source

    SciTech Connect

    Welton, R. F. Han, B. X.; Murray, S. N.; Pennisi, T. R.; Pillar, C.; Santana, M.; Stockli, M. P.; Dudnikov, V. G.; Turvey, M. W.

    2014-02-15

    The Spallation Neutron Source (SNS), a large scale neutron production facility, routinely operates with 30–40 mA peak current in the linac. Recent measurements have shown that our RF-driven internal antenna, Cs-enhanced, multi-cusp ion sources injects ∼55 mA of H{sup −} beam current (∼1 ms, 60 Hz) at 65-kV into a Radio Frequency Quadrupole (RFQ) accelerator through a closely coupled electrostatic Low-Energy Beam Transport system. Over the last several years a decrease in RFQ transmission and issues with internal antennas has stimulated source development at the SNS both for the internal and external antenna ion sources. This report discusses progress in improving internal antenna reliability, H{sup −} yield improvements which resulted from modifications to the outlet aperture assembly (applicable to both internal and external antenna sources) and studies made of the long standing problem of beam persistence with the external antenna source. The current status of the external antenna ion source will also be presented.

  19. Estimation of neutron production from accelerator head assembly of 15 MV medical LINAC using FLUKA simulations

    NASA Astrophysics Data System (ADS)

    Patil, B. J.; Chavan, S. T.; Pethe, S. N.; Krishnan, R.; Bhoraskar, V. N.; Dhole, S. D.

    2011-12-01

    For the production of a clinical 15 MeV photon beam, the design of accelerator head assembly has been optimized using Monte Carlo based FLUKA code. The accelerator head assembly consists of e-γ target, flattening filter, primary collimator and an adjustable rectangular secondary collimator. The accelerators used for radiation therapy generate continuous energy gamma rays called Bremsstrahlung (BR) by impinging high energy electrons on high Z materials. The electron accelerators operating above 10 MeV can result in the production of neutrons, mainly due to photo nuclear reaction (γ, n) induced by high energy photons in the accelerator head materials. These neutrons contaminate the therapeutic beam and give a non-negligible contribution to patient dose. The gamma dose and neutron dose equivalent at the patient plane (SSD = 100 cm) were obtained at different field sizes of 0 × 0, 10 × 10, 20 × 20, 30 × 30 and 40 × 40 cm 2, respectively. The maximum neutron dose equivalent is observed near the central axis of 30 × 30 cm 2 field size. This is 0.71% of the central axis photon dose rate of 0.34 Gy/min at 1 μA electron beam current.

  20. Polymer gel dosimetry for neutron beam in the Neutron Exposure Accelerator System for Biological Effect Experiments (NASBEE)

    NASA Astrophysics Data System (ADS)

    Kawamura, H.; Sato, H.; Hamano, T.; Suda, M.; Yoshii, H.

    2015-01-01

    This study aimed to investigate whether gel dosimetry could be used to measure neutron beams. We irradiated a BANG3-type polymer gel dosimeter using neutron beams in the Neutron exposure Accelerator System for Biological Effect Experiments (NASBEE) at the National Institute of Radiological Sciences (NIRS) in Japan. First, the polymer gels were irradiated from 0 to 7.0 Gy to investigate the dose-R2 responses. Irradiated gels were evaluated using 1.5-T magnetic resonance R2 images. Second, the polymer gels were irradiated to 1.0, 3.0, and 5.0 Gy to acquire a depth-R2 response curve. The dose-R2 response curve was linear up to approximately 7 Gy, with a slope of 1.25 Gy-1·s-1. Additionally, compared with the photon- irradiated gels, the neutron-irradiated gels had lower R2 values. The acquired depth-R2 curves of the central axis from the 3.0- and 5.0-Gy neutron dose-irradiated gels exhibited an initial build-up. Although, a detailed investigation is needed, polymer gel dosimetry is effective for measuring the dose-related R2 linearity and depth-R2 relationships of neutron beams.

  1. Electron acceleration in a post-flare decimetric continuum source

    NASA Astrophysics Data System (ADS)

    Subramanian, P.; White, S. M.; Karlický, M.; Sych, R.; Sawant, H. S.; Ananthakrishnan, S.

    2007-06-01

    Aims:To calculate the power budget for electron acceleration and the efficiency of the plasma emission mechanism in a post-flare decimetric continuum source. Methods: We have imaged a high brightness temperature (˜ 109 K) post-flare source at 1060 MHz with the Giant Metrewave Radio Telescope (GMRT). We use information from these images and the dynamic spectrum from the Hiraiso spectrograph together with the theoretical method described in Subramanian & Becker (2006, Sol. Phys., 237, 185) to calculate the power input to the electron acceleration process. The method assumes that the electrons are accelerated via a second-order Fermi acceleration mechanism. Results: We find that the power input to the nonthermal electrons is in the range 3× 1025-1026 erg/s. The efficiency of the overall plasma emission process starting from electron acceleration and culminating in the observed emission could range from 2.87× 10-9 to 2.38 × 10-8.

  2. Measurements of fusion neutrons from Magnetized Liner Inertial Fusion Experiments on the Z accelerator

    NASA Astrophysics Data System (ADS)

    Hahn, K. D.; Chandler, G. A.; Ruiz, C. L.; Gomez, M. R.; Slutz, S. A.; Sefkow, A. B.; Sinars, D. B.; Hansen, S. B.; Knapp, P. F.; Schmit, P. F.; Harding, E. C.; Awe, T. J.; Torres, J. A.; Jones, B.; Bur, J. A.; Cooper, G. W.; Styron, J. D.; Glebov, V. Yu.

    2015-11-01

    Strong evidence of thermonuclear neutron production has been observed during Magnetized Liner Inertial Fusion (MagLIF) experiments on the Z accelerator. So far, these experiments have utilized deuterium fuel and produced primary DD fusion neutron yields up to 2e12 with electron and ion stagnation temperatures in the 2-3 keV range. We present MagLIF neutron measurements and compare to other data and implosion simulations. In addition to primary DD and secondary DT yields and ion temperatures, other complex physics regarding the degree of fuel magnetization and liner density are elucidated by the neutron measurements. Neutron diagnostic development for deuterium and future deuterium-tritium fuel experiments are also discussed. Sandia is sponsored by the U.S. DOE's NNSA under contract DE-AC04-94AL85000.

  3. Study of muon-induced neutron production using accelerator muon beam at CERN

    SciTech Connect

    Nakajima, Y.; Lin, C. J.; Ochoa-Ricoux, J. P.; Draeger, E.; White, C. G.; Luk, K. B.; Steiner, H.

    2015-08-17

    Cosmogenic muon-induced neutrons are one of the most problematic backgrounds for various underground experiments for rare event searches. In order to accurately understand such backgrounds, experimental data with high-statistics and well-controlled systematics is essential. We performed a test experiment to measure muon-induced neutron production yield and energy spectrum using a high-energy accelerator muon beam at CERN. We successfully observed neutrons from 160 GeV/c muon interaction on lead, and measured kinetic energy distributions for various production angles. Works towards evaluation of absolute neutron production yield is underway. This work also demonstrates that the setup is feasible for a future large-scale experiment for more comprehensive study of muon-induced neutron production.

  4. Simulation study of accelerator based quasi-mono-energetic epithermal neutron beams for BNCT.

    PubMed

    Adib, M; Habib, N; Bashter, I I; El-Mesiry, M S; Mansy, M S

    2016-01-01

    Filtered neutron techniques were applied to produce quasi-mono-energetic neutron beams in the energy range of 1.5-7.5 keV at the accelerator port using the generated neutron spectrum from a Li (p, n) Be reaction. A simulation study was performed to characterize the filter components and transmitted beam lines. The feature of the filtered beams is detailed in terms of optimal thickness of the primary and additive components. A computer code named "QMNB-AS" was developed to carry out the required calculations. The filtered neutron beams had high purity and intensity with low contamination from the accompanying thermal, fast neutrons and γ-rays. PMID:26474209

  5. Fusion-neutron measurements for magnetized liner inertial fusion experiments on the Z accelerator

    DOE PAGESBeta

    Hahn, K. D.; Chandler, G. A.; Ruiz, C. L.; Cooper, G. W.; Gomez, M. R.; Slutz, S.; Sefkow, A. B.; Sinars, D. B.; Hansen, S. B.; Knapp, P. F.; et al

    2016-05-01

    Several magnetized liner inertial fusion (MagLIF) experiments have been conducted on the Z accelerator at Sandia National Laboratories since late 2013. Measurements of the primary DD (2.45 MeV) neutrons for these experiments suggest that the neutron production is thermonuclear. Primary DD yields up to 3e12 with ion temperatures ~2-3 keV have been achieved. Measurements of the secondary DT (14 MeV) neutrons indicate that the fuel is significantly magnetized. Measurements of down-scattered neutrons from the beryllium liner suggest ρRliner ~ 1g/cm2. Neutron bang times, estimated from neutron time-of-flight (nTOF) measurements, coincide with peak x-ray production. Furthermore, plans to improve and expandmore » the Z neutron diagnostic suite include neutron burn-history diagnostics, increased sensitivity and higher precision nTOF detectors, and neutron recoil-based yield and spectral measurements.« less

  6. Fusion-neutron-yield, activation measurements at the Z accelerator: design, analysis, and sensitivity.

    PubMed

    Hahn, K D; Cooper, G W; Ruiz, C L; Fehl, D L; Chandler, G A; Knapp, P F; Leeper, R J; Nelson, A J; Smelser, R M; Torres, J A

    2014-04-01

    We present a general methodology to determine the diagnostic sensitivity that is directly applicable to neutron-activation diagnostics fielded on a wide variety of neutron-producing experiments, which include inertial-confinement fusion (ICF), dense plasma focus, and ion beam-driven concepts. This approach includes a combination of several effects: (1) non-isotropic neutron emission; (2) the 1/r(2) decrease in neutron fluence in the activation material; (3) the spatially distributed neutron scattering, attenuation, and energy losses due to the fielding environment and activation material itself; and (4) temporally varying neutron emission. As an example, we describe the copper-activation diagnostic used to measure secondary deuterium-tritium fusion-neutron yields on ICF experiments conducted on the pulsed-power Z Accelerator at Sandia National Laboratories. Using this methodology along with results from absolute calibrations and Monte Carlo simulations, we find that for the diagnostic configuration on Z, the diagnostic sensitivity is 0.037% ± 17% counts/neutron per cm(2) and is ∼ 40% less sensitive than it would be in an ideal geometry due to neutron attenuation, scattering, and energy-loss effects. PMID:24784607

  7. Fusion-neutron-yield, activation measurements at the Z accelerator: Design, analysis, and sensitivity

    SciTech Connect

    Hahn, K. D. Ruiz, C. L.; Fehl, D. L.; Chandler, G. A.; Knapp, P. F.; Smelser, R. M.; Torres, J. A.; Cooper, G. W.; Nelson, A. J.; Leeper, R. J.

    2014-04-15

    We present a general methodology to determine the diagnostic sensitivity that is directly applicable to neutron-activation diagnostics fielded on a wide variety of neutron-producing experiments, which include inertial-confinement fusion (ICF), dense plasma focus, and ion beam-driven concepts. This approach includes a combination of several effects: (1) non-isotropic neutron emission; (2) the 1/r{sup 2} decrease in neutron fluence in the activation material; (3) the spatially distributed neutron scattering, attenuation, and energy losses due to the fielding environment and activation material itself; and (4) temporally varying neutron emission. As an example, we describe the copper-activation diagnostic used to measure secondary deuterium-tritium fusion-neutron yields on ICF experiments conducted on the pulsed-power Z Accelerator at Sandia National Laboratories. Using this methodology along with results from absolute calibrations and Monte Carlo simulations, we find that for the diagnostic configuration on Z, the diagnostic sensitivity is 0.037% ± 17% counts/neutron per cm{sup 2} and is ∼ 40% less sensitive than it would be in an ideal geometry due to neutron attenuation, scattering, and energy-loss effects.

  8. Fusion-neutron-yield, activation measurements at the Z accelerator: Design, analysis, and sensitivity

    NASA Astrophysics Data System (ADS)

    Hahn, K. D.; Cooper, G. W.; Ruiz, C. L.; Fehl, D. L.; Chandler, G. A.; Knapp, P. F.; Leeper, R. J.; Nelson, A. J.; Smelser, R. M.; Torres, J. A.

    2014-04-01

    We present a general methodology to determine the diagnostic sensitivity that is directly applicable to neutron-activation diagnostics fielded on a wide variety of neutron-producing experiments, which include inertial-confinement fusion (ICF), dense plasma focus, and ion beam-driven concepts. This approach includes a combination of several effects: (1) non-isotropic neutron emission; (2) the 1/r2 decrease in neutron fluence in the activation material; (3) the spatially distributed neutron scattering, attenuation, and energy losses due to the fielding environment and activation material itself; and (4) temporally varying neutron emission. As an example, we describe the copper-activation diagnostic used to measure secondary deuterium-tritium fusion-neutron yields on ICF experiments conducted on the pulsed-power Z Accelerator at Sandia National Laboratories. Using this methodology along with results from absolute calibrations and Monte Carlo simulations, we find that for the diagnostic configuration on Z, the diagnostic sensitivity is 0.037% ± 17% counts/neutron per cm2 and is ˜ 40% less sensitive than it would be in an ideal geometry due to neutron attenuation, scattering, and energy-loss effects.

  9. A liquid-hydrogen cold neutron source for the NBSR

    SciTech Connect

    Williams, R.E.; Roew, J.M.; Kopetka, P. )

    1992-01-01

    The National Bureau of Standards Reactor (NBSR) is a 20-MW research reactor operated by the National Institute of Standards and Technology. It was designed with a 55-cm-diam beamport for the purpose of installing a D[sub 2]O-ice cold neutron source, completed in 1987. The success of the cold source led to the construction of the Cold Neutron Research Facility, an experimental hall ultimately to have 7 neutron guides and 15 instruments. A liquid-hydrogen cold neutron source is being developed to replace the D[sub 2]O ice in order to increase the cold neutron yield. A simple, passively safe system has been designed with multiple barriers that prevent air from mixing with hydrogen. A thermosiphon will be used to maintain the liquid-hydrogen inventory in the moderator chamber. The thermosiphon relies on natural circulation; no pumps or moving parts are required to adequately cool the moderator chamber. The hydrogen condenser is cooled by a 3.5-kW helium refrigerator. A ballast tank is connected to the condenser so the entire hydrogen inventory can expand freely into the tank, providing completely passive protection against refrigerator failures.

  10. High Flux Isotope Reactor cold neutron source reference design concept

    SciTech Connect

    Selby, D.L.; Lucas, A.T.; Hyman, C.R.

    1998-05-01

    In February 1995, Oak Ridge National Laboratory`s (ORNL`s) deputy director formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. In May 1995, a team was formed to examine the feasibility of retrofitting a liquid hydrogen (LH{sub 2}) cold source facility into an existing HFIR beam tube. The results of this feasibility study indicated that the most practical location for such a cold source was the HB-4 beam tube. This location provides a potential flux environment higher than the Institut Laue-Langevin (ILL) vertical cold source and maximizes the space available for a future cold neutron guide hall expansion. It was determined that this cold neutron beam would be comparable, in cold neutron brightness, to the best facilities in the world, and a decision was made to complete a preconceptual design study with the intention of proceeding with an activity to install a working LH{sub 2} cold source in the HFIR HB-4 beam tube. During the development of the reference design the liquid hydrogen concept was changed to a supercritical hydrogen system for a number of reasons. This report documents the reference supercritical hydrogen design and its performance. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and testing, (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the conceptual design phase and establishes the baseline reference concept.

  11. The effect of a paraffin screen on the neutron dose at the maze door of a 15 MV linear accelerator

    SciTech Connect

    Krmar, M.; Kuzmanović, A.; Nikolić, D.; Kuzmanović, Z.; Ganezer, K.

    2013-08-15

    Purpose: The purpose of this study was to explore the effects of a paraffin screen located at various positions in the maze on the neutron dose equivalent at the maze door.Methods: The neutron dose equivalent was measured at the maze door of a room containing a 15 MV linear accelerator for x-ray therapy. Measurements were performed for several positions of the paraffin screen covering only 27.5% of the cross-sectional area of the maze. The neutron dose equivalent was also measured at all screen positions. Two simple models of the neutron source were considered in which the first assumed that the source was the cross-sectional area at the inner entrance of the maze, radiating neutrons in an isotropic manner. In the second model the reduction in the neutron dose equivalent at the maze door due to the paraffin screen was considered to be a function of the mean values of the neutron fluence and energy at the screen.Results: The results of this study indicate that the equivalent dose at the maze door was reduced by a factor of 3 through the use of a paraffin screen that was placed inside the maze. It was also determined that the contributions to the dosage from areas that were not covered by the paraffin screen as viewed from the dosimeter, were 2.5 times higher than the contributions from the covered areas. This study also concluded that the contributions of the maze walls, ceiling, and floor to the total neutron dose equivalent were an order of magnitude lower than those from the surface at the far end of the maze.Conclusions: This study demonstrated that a paraffin screen could be used to reduce the neutron dose equivalent at the maze door by a factor of 3. This paper also found that the reduction of the neutron dose equivalent was a linear function of the area covered by the maze screen and that the decrease in the dose at the maze door could be modeled as an exponential function of the product φ·E at the screen.

  12. Neutron Source Facility Training Simulator Based on EPICS

    SciTech Connect

    Park, Young Soo; Wei, Thomas Y.; Vilim, Richard B.; Grelle, Austin L.; Dworzanski, Pawel L.; Gohar, Yousry

    2015-01-01

    A plant operator training simulator is developed for training the plant operators as well as for design verification of plant control system (PCS) and plant protection system (PPS) for the Kharkov Institute of Physics and Technology Neutron Source Facility. The simulator provides the operator interface for the whole plant including the sub-critical assembly coolant loop, target coolant loop, secondary coolant loop, and other facility systems. The operator interface is implemented based on Experimental Physics and Industrial Control System (EPICS), which is a comprehensive software development platform for distributed control systems. Since its development at Argonne National Laboratory, it has been widely adopted in the experimental physics community, e.g. for control of accelerator facilities. This work is the first implementation for a nuclear facility. The main parts of the operator interface are the plant control panel and plant protection panel. The development involved implementation of process variable database, sequence logic, and graphical user interface (GUI) for the PCS and PPS utilizing EPICS and related software tools, e.g. sequencer for sequence logic, and control system studio (CSS-BOY) for graphical use interface. For functional verification of the PCS and PPS, a plant model is interfaced, which is a physics-based model of the facility coolant loops implemented as a numerical computer code. The training simulator is tested and demonstrated its effectiveness in various plant operation sequences, e.g. start-up, shut-down, maintenance, and refueling. It was also tested for verification of the plant protection system under various trip conditions.

  13. Intense Pulsed Neutron Source progress report for 1991

    SciTech Connect

    Not Available

    1991-12-31

    The IPNS Progress Report 10th Anniversary Edition is being published in recognition of the first ten years of successful IPNS operation. To emphasize the significance of this milestone, we wanted this report to stand apart from the previous IPNS Progress Reports, and the best way to do this, we thought, was to make the design and organization of the report significantly different. In their articles, authors were asked to emphasize not only advances made since IPNS began operating but also the groundwork that was laid at its predecessor facilities - Argonne`s ZING-P and ZING-P` prototype pulsed neutron sources and CP-5 reactor. Each article stands as a separate chapter in the report, since each represents a particular instrument or class of instruments, system, technique, or area of research. In some cases, contributions were similar to review articles in scientific journals, complete with extensive lists of references. Ten-year cumulative lists of members of IPNS committees and of scientists who have visited or done experiments at IPNS were assembled. A list of published and ``in press`` articles in journals, books, and conference proceedings, resulting from work done at IPNS during the past ten years, was compiled. And archival photographs of people and activities during the ten-year history of IPNS were located and were used liberally throughout the report. The titles of the chapters in this report are: accelerator; computer; radiation effects; powder; stress; single crystal; superconductivity; amorphous; small angle; reflection; quasielastic; inelastic; inelastic magnetic; deep inelastic; user program; the future; and publications.

  14. Intense Pulsed Neutron Source progress report for 1991

    SciTech Connect

    Schriesheim, Alan

    1991-01-01

    The IPNS Progress Report 10th Anniversary Edition is being published in recognition of the first ten years of successful IPNS operation. To emphasize the significance of this milestone, we wanted this report to stand apart from the previous IPNS Progress Reports, and the best way to do this, we thought, was to make the design and organization of the report significantly different. In their articles, authors were asked to emphasize not only advances made since IPNS began operating but also the groundwork that was laid at its predecessor facilities - Argonne's ZING-P and ZING-P' prototype pulsed neutron sources and CP-5 reactor. Each article stands as a separate chapter in the report, since each represents a particular instrument or class of instruments, system, technique, or area of research. In some cases, contributions were similar to review articles in scientific journals, complete with extensive lists of references. Ten-year cumulative lists of members of IPNS committees and of scientists who have visited or done experiments at IPNS were assembled. A list of published and in press'' articles in journals, books, and conference proceedings, resulting from work done at IPNS during the past ten years, was compiled. And archival photographs of people and activities during the ten-year history of IPNS were located and were used liberally throughout the report. The titles of the chapters in this report are: accelerator; computer; radiation effects; powder; stress; single crystal; superconductivity; amorphous; small angle; reflection; quasielastic; inelastic; inelastic magnetic; deep inelastic; user program; the future; and publications.

  15. Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.

    PubMed

    Cardenas, Carlos E; Nitsch, Paige L; Kudchadker, Rajat J; Howell, Rebecca M; Kry, Stephen F

    2016-01-01

    Out-of-field doses from radiotherapy can cause harmful side effects or eventually lead to secondary cancers. Scattered doses outside the applicator field, neutron source strength values, and neutron dose equivalents have not been broadly investigated for high-energy electron beams. To better understand the extent of these exposures, we measured out-of-field dose characteristics of electron applicators for high-energy electron beams on two Varian 21iXs, a Varian TrueBeam, and an Elekta Versa HD operating at various energy levels. Out-of-field dose profiles and percent depth-dose curves were measured in a Wellhofer water phantom using a Farmer ion chamber. Neutron dose was assessed using a combination of moderator buckets and gold activation foils placed on the treatment couch at various locations in the patient plane on both the Varian 21iX and Elekta Versa HD linear accelerators. Our findings showed that out-of-field electron doses were highest for the highest electron energies. These doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. The Elekta linear accelerator had higher electron out-of-field doses than the Varian units examined, and the Elekta dose profiles exhibited a second dose peak about 20 to 30 cm from central-axis, which was found to be higher than typical out-of-field doses from photon beams. Electron doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. With respect to neutron dosimetry, Q values and neutron dose equivalents increased with electron beam energy. Neutron contamination from electron beams was found to be much lower than that from photon beams. Even though the neutron dose equivalent for electron beams represented a small portion of neutron doses observed under photon beams, neutron doses from electron beams may need to be considered for special cases. PMID:27455499

  16. EXPERIENCE WITH COLLABORATIVE DEVELOPMENT FOR THE SPALLATION NEUTRON SOURCE FROM A PARTNER LAB PERSPECTIVE.

    SciTech Connect

    HOFF, L.T.

    2005-10-10

    Collaborative development and operation of large physics experiments is fairly common. Less common is the collaborative development or operation of accelerators. A current example of the latter is the Spallation Neutron Source (SNS). The SNS project was conceived as a collaborative effort between six DOE facilities. In the SNS case, the control system was also developed collaboratively. The SNS project has now moved beyond the collaborative development phase and into the phase where Oak Ridge National Lab (ORNL) is integrating contributions from collaborating ''partner labs'' and is beginning accelerator operations. In this paper, the author reflects on the benefits and drawbacks of the collaborative development of an accelerator control system as implemented for the SNS project from the perspective of a partner lab.

  17. Nonlinear Acceleration Methods for Even-Parity Neutron Transport

    SciTech Connect

    W. J. Martin; C. R. E. De Oliveira; H. Park

    2010-05-01

    Convergence acceleration methods for even-parity transport were developed that have the potential to speed up transport calculations and provide a natural avenue for an implicitly coupled multiphysics code. An investigation was performed into the acceleration properties of the introduction of a nonlinear quasi-diffusion-like tensor in linear and nonlinear solution schemes. Using the tensor reduced matrix as a preconditioner for the conjugate gradients method proves highly efficient and effective. The results for the linear and nonlinear case serve as the basis for further research into the application in a full three-dimensional spherical-harmonics even-parity transport code. Once moved into the nonlinear solution scheme, the implicit coupling of the convergence accelerated transport method into codes for other physics can be done seamlessly, providing an efficient, fully implicitly coupled multiphysics code with high order transport.

  18. Optimizing moderator dimensions for neutron scattering at the spallation neutron source

    SciTech Connect

    Zhao, J. K.; Robertson, J. L.; Herwig, Kenneth W.; Gallmeier, Franz X.; Riemer, Bernard W.

    2013-12-15

    In this work, we investigate the effect of neutron moderator dimensions on the performance of neutron scattering instruments at the Spallation Neutron Source (SNS). In a recent study of the planned second target station at the SNS facility, we have found that the dimensions of a moderator play a significant role in determining its surface brightness. A smaller moderator may be significantly brighter over a smaller viewing area. One of the immediate implications of this finding is that for modern neutron scattering instrument designs, moderator dimensions and brightness have to be incorporated as an integrated optimization parameter. Here, we establish a strategy of matching neutron scattering instruments with moderators using analytical and Monte Carlo techniques. In order to simplify our treatment, we group the instruments into two broad categories: those with natural collimation and those that use neutron guide systems. For instruments using natural collimation, the optimal moderator selection depends on the size of the moderator, the sample, and the moderator brightness. The desired beam divergence only plays a role in determining the distance between sample and moderator. For instruments using neutron optical systems, the smallest moderator available that is larger than the entrance dimension of the closest optical element will perform the best (assuming, as is the case here that smaller moderators are brighter)

  19. Optimizing moderator dimensions for neutron scattering at the spallation neutron source.

    PubMed

    Zhao, J K; Robertson, J L; Herwig, Kenneth W; Gallmeier, Franz X; Riemer, Bernard W

    2013-12-01

    In this work, we investigate the effect of neutron moderator dimensions on the performance of neutron scattering instruments at the Spallation Neutron Source (SNS). In a recent study of the planned second target station at the SNS facility, we have found that the dimensions of a moderator play a significant role in determining its surface brightness. A smaller moderator may be significantly brighter over a smaller viewing area. One of the immediate implications of this finding is that for modern neutron scattering instrument designs, moderator dimensions and brightness have to be incorporated as an integrated optimization parameter. Here, we establish a strategy of matching neutron scattering instruments with moderators using analytical and Monte Carlo techniques. In order to simplify our treatment, we group the instruments into two broad categories: those with natural collimation and those that use neutron guide systems. For instruments using natural collimation, the optimal moderator selection depends on the size of the moderator, the sample, and the moderator brightness. The desired beam divergence only plays a role in determining the distance between sample and moderator. For instruments using neutron optical systems, the smallest moderator available that is larger than the entrance dimension of the closest optical element will perform the best (assuming, as is the case here that smaller moderators are brighter). PMID:24387465

  20. Beamed neutron emission driven by laser accelerated light ions

    NASA Astrophysics Data System (ADS)

    Kar, S.; Green, A.; Ahmed, H.; Alejo, A.; Robinson, A. P. L.; Cerchez, M.; Clarke, R.; Doria, D.; Dorkings, S.; Fernandez, J.; Mirfayzi, S. R.; McKenna, P.; Naughton, K.; Neely, D.; Norreys, P.; Peth, C.; Powell, H.; Ruiz, J. A.; Swain, J.; Willi, O.; Borghesi, M.

    2016-05-01

    Highly anisotropic, beam-like neutron emission with peak flux of the order of 109 n/sr was obtained from light nuclei reactions in a pitcher–catcher scenario, by employing MeV ions driven by a sub-petawatt laser. The spatial profile of the neutron beam, fully captured for the first time by employing a CR39 nuclear track detector, shows a FWHM divergence angle of ∼ 70^\\circ , with a peak flux nearly an order of magnitude higher than the isotropic component elsewhere. The observed beamed flux of neutrons is highly favourable for a wide range of applications, and indeed for further transport and moderation to thermal energies. A systematic study employing various combinations of pitcher–catcher materials indicates the dominant reactions being d(p, n+p)1H and d(d,n)3He. Albeit insufficient cross-section data are available for modelling, the observed anisotropy in the neutrons’ spatial and spectral profiles is most likely related to the directionality and high energy of the projectile ions.