Sample records for accelerometer cut points

  1. Calibration and comparison of accelerometer cut points in preschool children.

    PubMed

    van Cauwenberghe, Eveline; Labarque, Valery; Trost, Stewart G; de Bourdeaudhuij, Ilse; Cardon, Greet

    2011-06-01

    The present study aimed to develop accelerometer cut points to classify physical activities (PA) by intensity in preschoolers and to investigate discrepancies in PA levels when applying various accelerometer cut points. To calibrate the accelerometer, 18 preschoolers (5.8 ± 0.4 years) performed eleven structured activities and one free play session while wearing a GT1M ActiGraph accelerometer using 15 s epochs. The structured activities were chosen based on the direct observation system Children's Activity Rating Scale (CARS) while the criterion measure of PA intensity during free play was provided using a second-by-second observation protocol (modified CARS). Receiver Operating Characteristic (ROC) curve analyses were used to determine the accelerometer cut points. To examine the classification differences, accelerometer data of four consecutive days from 114 preschoolers (5.5 ± 0.3 years) were classified by intensity according to previously published and the newly developed accelerometer cut points. Differences in predicted PA levels were evaluated using repeated measures ANOVA and Chi Square test. Cut points were identified at 373 counts/15 s for light (sensitivity: 86%; specificity: 91%; Area under ROC curve: 0.95), 585 counts/15 s for moderate (87%; 82%; 0.91) and 881 counts/15 s for vigorous PA (88%; 91%; 0.94). Further, applying various accelerometer cut points to the same data resulted in statistically and biologically significant differences in PA. Accelerometer cut points were developed with good discriminatory power for differentiating between PA levels in preschoolers and the choice of accelerometer cut points can result in large discrepancies.

  2. Calibration of GENEActiv accelerometer wrist cut-points for the assessment of physical activity intensity of preschool aged children.

    PubMed

    Roscoe, Clare M P; James, Rob S; Duncan, Michael J

    2017-08-01

    This study sought to validate cut-points for use of wrist-worn GENEActiv accelerometer data, to analyse preschool children's (4 to 5 year olds) physical activity (PA) levels via calibration with oxygen consumption values (VO 2 ). This was a laboratory-based calibration study. Twenty-one preschool children, aged 4.7 ± 0.5 years old, completed six activities (ranging from lying supine to running) whilst wearing the GENEActiv accelerometers at two locations (left and right wrist), these being the participants' non-dominant and dominant wrist, and a Cortex face mask for gas analysis. VO 2 data was used for the assessment of criterion validity. Location specific activity intensity cut-points were established via receiver operator characteristic curve (ROC) analysis. The GENEActiv accelerometers, irrespective of their location, accurately discriminated between all PA intensities (sedentary, light, and moderate and above), with the dominant wrist monitor providing a slightly more precise discrimination at light PA and the non-dominant at the sedentary behaviour and moderate and above intensity levels (area under the curve (AUC) for non-dominant = 0.749-0.993, compared to AUC dominant = 0.760-0.988). This study establishes wrist-worn physical activity cut-points for the GENEActiv accelerometer in preschoolers. What is Known: • GENEActiv accelerometers have been validated as a PA measurement tool in adolescents and adults. • No study to date has validated the GENEActiv accelerometers in preschoolers. What is New: • Cut-points were determined for the wrist-worn GENEActiv accelerometer in preschoolers. • These cut-points can be used in future research to help classify and increase preschoolers' compliance rates with PA.

  3. Measuring moderate-intensity walking in older adults using the ActiGraph accelerometer.

    PubMed

    Barnett, Anthony; van den Hoek, Daniel; Barnett, David; Cerin, Ester

    2016-12-08

    Accelerometry is the method of choice for objectively assessing physical activity in older adults. Many studies have used an accelerometer count cut point corresponding to 3 metabolic equivalents (METs) derived in young adults during treadmill walking and running with a resting metabolic rate (RMR) assumed at 3.5 mL · kg -1  · min -1 (corresponding to 1 MET). RMR is lower in older adults; therefore, their 3 MET level occurs at a lower absolute energy expenditure making the cut point derived from young adults inappropriate for this population. The few studies determining older adult specific moderate-to-vigorous intensity physical activity (MVPA) cut points had methodological limitations, such as not measuring RMR and using treadmill walking. This study determined a MVPA hip-worn accelerometer cut point for older adults using measured RMR and overground walking. Following determination of RMR, 45 older adults (mean age 70.2 ± 7 years, range 60-87.6 years) undertook an outdoor, overground walking protocol with accelerometer count and energy expenditure determined at five walking speeds. Mean RMR was 2.8 ± 0.6 mL · kg -1  · min -1 . The MVPA cut points (95% CI) determined using linear mixed models were: vertical axis 1013 (734, 1292) counts · min -1 ; vector magnitude 1924 (1657, 2192) counts · min -1 ; and walking speed 2.5 (2.2, 2.8) km · hr -1 . High levels of inter-individual variability in cut points were found. These MVPA accelerometer and speed cut points for walking, the most popular physical activity in older adults, were lower than those for younger adults. Using cut points determined in younger adults for older adult population studies is likely to underestimate time spent engaged in MVPA. In addition, prescription of walking speed based on the adult cut point is likely to result in older adults working at a higher intensity than intended.

  4. A calibration protocol for population-specific accelerometer cut-points in children.

    PubMed

    Mackintosh, Kelly A; Fairclough, Stuart J; Stratton, Gareth; Ridgers, Nicola D

    2012-01-01

    To test a field-based protocol using intermittent activities representative of children's physical activity behaviours, to generate behaviourally valid, population-specific accelerometer cut-points for sedentary behaviour, moderate, and vigorous physical activity. Twenty-eight children (46% boys) aged 10-11 years wore a hip-mounted uniaxial GT1M ActiGraph and engaged in 6 activities representative of children's play. A validated direct observation protocol was used as the criterion measure of physical activity. Receiver Operating Characteristics (ROC) curve analyses were conducted with four semi-structured activities to determine the accelerometer cut-points. To examine classification differences, cut-points were cross-validated with free-play and DVD viewing activities. Cut-points of ≤ 372, >2160 and >4806 counts • min(-1) representing sedentary, moderate and vigorous intensity thresholds, respectively, provided the optimal balance between the related needs for sensitivity (accurately detecting activity) and specificity (limiting misclassification of the activity). Cross-validation data demonstrated that these values yielded the best overall kappa scores (0.97; 0.71; 0.62), and a high classification agreement (98.6%; 89.0%; 87.2%), respectively. Specificity values of 96-97% showed that the developed cut-points accurately detected physical activity, and sensitivity values (89-99%) indicated that minutes of activity were seldom incorrectly classified as inactivity. The development of an inexpensive and replicable field-based protocol to generate behaviourally valid and population-specific accelerometer cut-points may improve the classification of physical activity levels in children, which could enhance subsequent intervention and observational studies.

  5. Hip and Wrist Accelerometer Algorithms for Free-Living Behavior Classification.

    PubMed

    Ellis, Katherine; Kerr, Jacqueline; Godbole, Suneeta; Staudenmayer, John; Lanckriet, Gert

    2016-05-01

    Accelerometers are a valuable tool for objective measurement of physical activity (PA). Wrist-worn devices may improve compliance over standard hip placement, but more research is needed to evaluate their validity for measuring PA in free-living settings. Traditional cut-point methods for accelerometers can be inaccurate and need testing in free living with wrist-worn devices. In this study, we developed and tested the performance of machine learning (ML) algorithms for classifying PA types from both hip and wrist accelerometer data. Forty overweight or obese women (mean age = 55.2 ± 15.3 yr; BMI = 32.0 ± 3.7) wore two ActiGraph GT3X+ accelerometers (right hip, nondominant wrist; ActiGraph, Pensacola, FL) for seven free-living days. Wearable cameras captured ground truth activity labels. A classifier consisting of a random forest and hidden Markov model classified the accelerometer data into four activities (sitting, standing, walking/running, and riding in a vehicle). Free-living wrist and hip ML classifiers were compared with each other, with traditional accelerometer cut points, and with an algorithm developed in a laboratory setting. The ML classifier obtained average values of 89.4% and 84.6% balanced accuracy over the four activities using the hip and wrist accelerometer, respectively. In our data set with average values of 28.4 min of walking or running per day, the ML classifier predicted average values of 28.5 and 24.5 min of walking or running using the hip and wrist accelerometer, respectively. Intensity-based cut points and the laboratory algorithm significantly underestimated walking minutes. Our results demonstrate the superior performance of our PA-type classification algorithm, particularly in comparison with traditional cut points. Although the hip algorithm performed better, additional compliance achieved with wrist devices might justify using a slightly lower performing algorithm.

  6. Validation of Accelerometer Cut-Points in Children With Cerebral Palsy Aged 4 to 5 Years.

    PubMed

    Keawutan, Piyapa; Bell, Kristie L; Oftedal, Stina; Davies, Peter S W; Boyd, Roslyn N

    2016-01-01

    To derive and validate triaxial accelerometer cut-points in children with cerebral palsy (CP) and compare these with previously established cut-points in children with typical development. Eighty-four children with CP aged 4 to 5 years wore the ActiGraph during a play-based gross motor function measure assessment that was video-taped for direct observation. Receiver operating characteristic and Bland-Altman plots were used for analyses. The ActiGraph had good classification accuracy in Gross Motor Function Classification System (GMFCS) levels III and V and fair classification accuracy in GMFCS levels I, II, and IV. These results support the use of the previously established cut-points for sedentary time of 820 counts per minute in children with CP aged 4 to 5 years across all functional abilities. The cut-point provides an objective measure of sedentary and active time in children with CP. The cut-point is applicable to group data but not for individual children.

  7. Classification of Physical Activity Cut-Points and the Estimation of Energy Expenditure during Walking Using the GT3X+ Accelerometer in Overweight and Obese Adults

    ERIC Educational Resources Information Center

    Howe, Christopher C. F.; Moir, Hannah J.; Easton, Chris

    2017-01-01

    This study establishes tri-axial activity count (AC) cut-points for the GT3X+ accelerometer to classify physical activity intensity in overweight and obese adults. Further, we examined the accuracy of established and novel energy expenditure (EE) prediction equations based on AC and other metrics. "Part 1": Twenty overweight or obese…

  8. Effects of Varying Epoch Lengths, Wear Time Algorithms, and Activity Cut-Points on Estimates of Child Sedentary Behavior and Physical Activity from Accelerometer Data.

    PubMed

    Banda, Jorge A; Haydel, K Farish; Davila, Tania; Desai, Manisha; Bryson, Susan; Haskell, William L; Matheson, Donna; Robinson, Thomas N

    2016-01-01

    To examine the effects of accelerometer epoch lengths, wear time (WT) algorithms, and activity cut-points on estimates of WT, sedentary behavior (SB), and physical activity (PA). 268 7-11 year-olds with BMI ≥ 85th percentile for age and sex wore accelerometers on their right hips for 4-7 days. Data were processed and analyzed at epoch lengths of 1-, 5-, 10-, 15-, 30-, and 60-seconds. For each epoch length, WT minutes/day was determined using three common WT algorithms, and minutes/day and percent time spent in SB, light (LPA), moderate (MPA), and vigorous (VPA) PA were determined using five common activity cut-points. ANOVA tested differences in WT, SB, LPA, MPA, VPA, and MVPA when using the different epoch lengths, WT algorithms, and activity cut-points. WT minutes/day varied significantly by epoch length when using the NHANES WT algorithm (p < .0001), but did not vary significantly by epoch length when using the ≥ 20 minute consecutive zero or Choi WT algorithms. Minutes/day and percent time spent in SB, LPA, MPA, VPA, and MVPA varied significantly by epoch length for all sets of activity cut-points tested with all three WT algorithms (all p < .0001). Across all epoch lengths, minutes/day and percent time spent in SB, LPA, MPA, VPA, and MVPA also varied significantly across all sets of activity cut-points with all three WT algorithms (all p < .0001). The common practice of converting WT algorithms and activity cut-point definitions to match different epoch lengths may introduce significant errors. Estimates of SB and PA from studies that process and analyze data using different epoch lengths, WT algorithms, and/or activity cut-points are not comparable, potentially leading to very different results, interpretations, and conclusions, misleading research and public policy.

  9. Validation of three short physical activity questionnaires with accelerometers among university students in Spain.

    PubMed

    Rodríguez-Muñoz, Sheila; Corella, Cristina; Abarca-Sos, Alberto; Zaragoza, Javier

    2017-12-01

    Physical activity (PA) in university students has not been analyzed with specific questionnaires tailored to this population. Therefore, the purpose of this study was to analyze the validity of three PA questionnaires developed on other populations comparing with accelerometer values: counts and moderate to vigorous PA (MVPA) calculated with uniaxial and triaxial cut points. One hundred and forty-five university students (of whom, 92 women) from Spain wore an accelerometer GT3X or GTX+ to collect PA data of 7 full days. Three questionnaires, Physical Activity Questionnaire for Adults (PAQ-AD), Assessment of Physical Activity Questionnaire (APALQ), and the International Physical Activity Questionnaire Short Form (IPAQ-SF) were administrated jointly with the collection of accelerometer values. Finally, after the application of inclusion criteria, data from 95 participants (62 women) with a mean age of 21.96±2.33 years were analyzed to compare the instruments measures. The correlational analysis showed that PAQ-AD (0.44-0.56) and IPAQ-SF (0.26-0.69) questionnaires were significantly related to accelerometers scores: counts, uniaxial MVPA and triaxial MVPA. Conversely, APALQ displayed no significant relations for males with accelerometers scores for MVPA created with both cut points. PAQ-AD and IPAQ-SF questionnaires have shown adequate validity to use with Spanish university students. The use of counts to validate self-report data in order to reduce the variability display by MVPA created with different cut points is discussed. Finally, validated instruments to measure PA in university students will allow implementation of strategies for PA promotion based on reliable data.

  10. Validation of accelerometer cut points in toddlers with and without cerebral palsy.

    PubMed

    Oftedal, Stina; Bell, Kristie L; Davies, Peter S W; Ware, Robert S; Boyd, Roslyn N

    2014-09-01

    The purpose of this study was to validate uni- and triaxial ActiGraph cut points for sedentary time in toddlers with cerebral palsy (CP) and typically developing children (TDC). Children (n = 103, 61 boys, mean age = 2 yr, SD = 6 months, range = 1 yr 6 months-3 yr) were divided into calibration (n = 65) and validation (n = 38) samples with separate analyses for TDC (n = 28) and ambulant (Gross Motor Function Classification System I-III, n = 51) and nonambulant (Gross Motor Function Classification System IV-V, n = 25) children with CP. An ActiGraph was worn during a videotaped assessment. Behavior was coded as sedentary or nonsedentary. Receiver operating characteristic-area under the curve analysis determined the classification accuracy of accelerometer data. Predictive validity was determined using the Bland-Altman analysis. Classification accuracy for uniaxial data was fair for the ambulatory CP and TDC group but poor for the nonambulatory CP group. Triaxial data showed good classification accuracy for all groups. The uniaxial ambulatory CP and TDC cut points significantly overestimated sedentary time (bias = -10.5%, 95% limits of agreement [LoA] = -30.2% to 9.1%; bias = -17.3%, 95% LoA = -44.3% to 8.3%). The triaxial ambulatory and nonambulatory CP and TDC cut points provided accurate group-level measures of sedentary time (bias = -1.5%, 95% LoA = -20% to 16.8%; bias = 2.1%, 95% LoA = -17.3% to 21.5%; bias = -5.1%, 95% LoA = -27.5% to 16.1%). Triaxial accelerometers provide useful group-level measures of sedentary time in children with CP across the spectrum of functional abilities and TDC. Uniaxial cut points are not recommended.

  11. Performance of thigh-mounted triaxial accelerometer algorithms in objective quantification of sedentary behaviour and physical activity in older adults

    PubMed Central

    Verschueren, Sabine M. P.; Degens, Hans; Morse, Christopher I.; Onambélé, Gladys L.

    2017-01-01

    Accurate monitoring of sedentary behaviour and physical activity is key to investigate their exact role in healthy ageing. To date, accelerometers using cut-off point models are most preferred for this, however, machine learning seems a highly promising future alternative. Hence, the current study compared between cut-off point and machine learning algorithms, for optimal quantification of sedentary behaviour and physical activity intensities in the elderly. Thus, in a heterogeneous sample of forty participants (aged ≥60 years, 50% female) energy expenditure during laboratory-based activities (ranging from sedentary behaviour through to moderate-to-vigorous physical activity) was estimated by indirect calorimetry, whilst wearing triaxial thigh-mounted accelerometers. Three cut-off point algorithms and a Random Forest machine learning model were developed and cross-validated using the collected data. Detailed analyses were performed to check algorithm robustness, and examine and benchmark both overall and participant-specific balanced accuracies. This revealed that the four models can at least be used to confidently monitor sedentary behaviour and moderate-to-vigorous physical activity. Nevertheless, the machine learning algorithm outperformed the cut-off point models by being robust for all individual’s physiological and non-physiological characteristics and showing more performance of an acceptable level over the whole range of physical activity intensities. Therefore, we propose that Random Forest machine learning may be optimal for objective assessment of sedentary behaviour and physical activity in older adults using thigh-mounted triaxial accelerometry. PMID:29155839

  12. Performance of thigh-mounted triaxial accelerometer algorithms in objective quantification of sedentary behaviour and physical activity in older adults.

    PubMed

    Wullems, Jorgen A; Verschueren, Sabine M P; Degens, Hans; Morse, Christopher I; Onambélé, Gladys L

    2017-01-01

    Accurate monitoring of sedentary behaviour and physical activity is key to investigate their exact role in healthy ageing. To date, accelerometers using cut-off point models are most preferred for this, however, machine learning seems a highly promising future alternative. Hence, the current study compared between cut-off point and machine learning algorithms, for optimal quantification of sedentary behaviour and physical activity intensities in the elderly. Thus, in a heterogeneous sample of forty participants (aged ≥60 years, 50% female) energy expenditure during laboratory-based activities (ranging from sedentary behaviour through to moderate-to-vigorous physical activity) was estimated by indirect calorimetry, whilst wearing triaxial thigh-mounted accelerometers. Three cut-off point algorithms and a Random Forest machine learning model were developed and cross-validated using the collected data. Detailed analyses were performed to check algorithm robustness, and examine and benchmark both overall and participant-specific balanced accuracies. This revealed that the four models can at least be used to confidently monitor sedentary behaviour and moderate-to-vigorous physical activity. Nevertheless, the machine learning algorithm outperformed the cut-off point models by being robust for all individual's physiological and non-physiological characteristics and showing more performance of an acceptable level over the whole range of physical activity intensities. Therefore, we propose that Random Forest machine learning may be optimal for objective assessment of sedentary behaviour and physical activity in older adults using thigh-mounted triaxial accelerometry.

  13. Combinations of Epoch Durations and Cut-Points to Estimate Sedentary Time and Physical Activity among Adolescents

    ERIC Educational Resources Information Center

    Fröberg, Andreas; Berg, Christina; Larsson, Christel; Boldemann, Cecilia; Raustorp, Anders

    2017-01-01

    The purpose of the current study was to investigate how combinations of different epoch durations and cut-points affect the estimations of sedentary time and physical activity in adolescents. Accelerometer data from 101 adolescents were derived and 30 combinations were used to estimate sedentary time, light, moderate, vigorous, and combined…

  14. Establishing school day pedometer step count cut-points using ROC curves in low-income children.

    PubMed

    Burns, Ryan D; Brusseau, Timothy A; Fu, You; Hannon, James C

    2016-05-01

    Previous research has not established pedometer step count cut-points that discriminate children that meet school day physical activity recommendations using a tri-axial ActiGraph accelerometer criterion. The purpose of this study was to determine step count cut-points that associate with 30min of school day moderate-to-vigorous physical activity (MVPA) in school-aged children. Participants included 1053 school-aged children (mean age=8.4±1.8years) recruited from three low-income schools from the state of Utah in the U.S. Physical activity was assessed using Yamax DigiWalker CW600 pedometers and ActiGraph wGT3X-BT triaxial accelerometers that were concurrently worn during school hours. Data were collected at each school during the 2014-2015 school year. Receiver operating characteristic (ROC) curves were used to determine pedometer step count cut-points that associated with at least 30min of MVPA during school hours. Cut-points were determined using the maximum Youden's J statistic (J max). For the total sample, the area-under-the-curve (AUC) was 0.77 (p<0.001) with a pedometer cut-point of 5505 steps (J max=0.46, Sensitivity=63%, Specificity=84%; Accuracy=76%). Step counts showed greater diagnostic ability in girls (AUC=0.81, p<0.001; Cut-point=5306 steps; Accuracy=78.8%) compared to boys (AUC=0.72, p<0.01; Cut-point=5786 steps; Accuracy=71.4%). Pedometer step counts showed good diagnostic ability in girls and fair diagnostic ability in boys for discriminating children that met at least 30min of MVPA during school hours. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Comparison of accelerometer cut points for predicting activity intensity in youth.

    PubMed

    Trost, Stewart G; Loprinzi, Paul D; Moore, Rebecca; Pfeiffer, Karin A

    2011-07-01

    The absence of comparative validity studies has prevented researchers from reaching consensus regarding the application of intensity-related accelerometer cut points for children and adolescents. This study aimed to evaluate the classification accuracy of five sets of independently developed ActiGraph cut points using energy expenditure, measured by indirect calorimetry, as a criterion reference standard. A total of 206 participants between the ages of 5 and 15 yr completed 12 standardized activity trials. Trials consisted of sedentary activities (lying down, writing, computer game), lifestyle activities (sweeping, laundry, throw and catch, aerobics, basketball), and ambulatory activities (comfortable walk, brisk walk, brisk treadmill walk, running). During each trial, participants wore an ActiGraph GT1M, and V˙O2 was measured breath-by-breath using the Oxycon Mobile portable metabolic system. Physical activity intensity was estimated using five independently developed cut points: Freedson/Trost (FT), Puyau (PU), Treuth (TR), Mattocks (MT), and Evenson (EV). Classification accuracy was evaluated via weighted κ statistics and area under the receiver operating characteristic curve (ROC-AUC). Across all four intensity levels, the EV (κ=0.68) and FT (κ=0.66) cut points exhibited significantly better agreement than TR (κ=0.62), MT (κ=0.54), and PU (κ=0.36). The EV and FT cut points exhibited significantly better classification accuracy for moderate- to vigorous-intensity physical activity (ROC-AUC=0.90) than TR, PU, or MT cut points (ROC-AUC=0.77-0.85). Only the EV cut points provided acceptable classification accuracy for all four levels of physical activity intensity and performed well among children of all ages. The widely applied sedentary cut point of 100 counts per minute exhibited excellent classification accuracy (ROC-AUC=0.90). On the basis of these findings, we recommend that researchers use the EV ActiGraph cut points to estimate time spent in sedentary, light-, moderate-, and vigorous-intensity activity in children and adolescents.

  16. A catalog of rules, variables, and definitions applied to accelerometer data in the National Health and Nutrition Examination Survey, 2003-2006.

    PubMed

    Tudor-Locke, Catrine; Camhi, Sarah M; Troiano, Richard P

    2012-01-01

    The National Health and Nutrition Examination Survey (NHANES) included accelerometry in the 2003-2006 data collection cycles. Researchers have used these data since their release in 2007, but the data have not been consistently treated, examined, or reported. The objective of this study was to aggregate data from studies using NHANES accelerometry data and to catalogue study decision rules, derived variables, and cut point definitions to facilitate a more uniform approach to these data. We conducted a PubMed search of English-language articles published (or indicated as forthcoming) from January 2007 through December 2011. Our initial search yielded 74 articles, plus 1 article that was not indexed in PubMed. After excluding 21 articles, we extracted and tabulated details on 54 studies to permit comparison among studies. The 54 articles represented various descriptive, methodological, and inferential analyses. Although some decision rules for treating data (eg, criteria for minimal wear-time) were consistently applied, cut point definitions used for accelerometer-derived variables (eg, time spent in various intensities of physical activity) were especially diverse. Unique research questions may require equally unique analytical approaches; some inconsistency in approaches must be tolerated if scientific discovery is to be encouraged. This catalog provides a starting point for researchers to consider relevant and/or comparable accelerometer decision rules, derived variables, and cut point definitions for their own research questions.

  17. Improving Hip-Worn Accelerometer Estimates of Sitting Using Machine Learning Methods.

    PubMed

    Kerr, Jacqueline; Carlson, Jordan; Godbole, Suneeta; Cadmus-Bertram, Lisa; Bellettiere, John; Hartman, Sheri

    2018-02-13

    To improve estimates of sitting time from hip worn accelerometers used in large cohort studies by employing machine learning methods developed on free living activPAL data. Thirty breast cancer survivors concurrently wore a hip worn accelerometer and a thigh worn activPAL for 7 days. A random forest classifier, trained on the activPAL data, was employed to detect sitting, standing and sit-stand transitions in 5 second windows in the hip worn accelerometer. The classifier estimates were compared to the standard accelerometer cut point and significant differences across different bout lengths were investigated using mixed effect models. Overall, the algorithm predicted the postures with moderate accuracy (stepping 77%, standing 63%, sitting 67%, sit to stand 52% and stand to sit 51%). Daily level analyses indicated that errors in transition estimates were only occurring during sitting bouts of 2 minutes or less. The standard cut point was significantly different from the activPAL across all bout lengths, overestimating short bouts and underestimating long bouts. This is among the first algorithms for sitting and standing for hip worn accelerometer data to be trained from entirely free living activPAL data. The new algorithm detected prolonged sitting which has been shown to be most detrimental to health. Further validation and training in larger cohorts is warranted.This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  18. The Relationship of Actigraph Accelerometer Cut-Points for Estimating Physical Activity with Selected Health Outcomes: Results from NHANES 2003-06

    ERIC Educational Resources Information Center

    Loprinzi, Paul D.; Lee, Hyo; Cardinal, Bradley J.; Crespo, Carlos J.; Andersen, Ross E.; Smit, Ellen

    2012-01-01

    The purpose of this study was to examine the influence of child and adult cut-points on physical activity (PA) intensity, the prevalence of meeting PA guidelines, and association with selected health outcomes. Participants (6,578 adults greater than or equal to 18 years, and 3,174 children and adolescents less than or equal to 17 years) from the…

  19. Validation of Accelerometer Prediction Equations in Children with Chronic Disease.

    PubMed

    Stephens, Samantha; Takken, Tim; Esliger, Dale W; Pullenayegum, Eleanor; Beyene, Joseph; Tremblay, Mark; Schneiderman, Jane; Biggar, Doug; Longmuir, Pat; McCrindle, Brian; Abad, Audrey; Ignas, Dan; Van Der Net, Janjaap; Feldman, Brian

    2016-02-01

    The purpose of this study was to assess the criterion validity of existing accelerometer-based energy expenditure (EE) prediction equations among children with chronic conditions, and to develop new prediction equations. Children with congenital heart disease (CHD), cystic fibrosis (CF), dermatomyositis (JDM), juvenile arthritis (JA), inherited muscle disease (IMD), and hemophilia (HE) completed 7 tasks while EE was measured using indirect calorimetry with counts determined by accelerometer. Agreement between predicted EE and measured EE was assessed. Disease-specific equations and cut points were developed and cross-validated. In total, 196 subjects participated. One participant dropped out before testing due to time constraints, while 15 CHD, 32 CF, 31 JDM, 31 JA, 30 IMD, 28 HE, and 29 healthy controls completed the study. Agreement between predicted and measured EE varied across disease group and ranged from (ICC) .13-.46. Disease-specific prediction equations exhibited a range of results (ICC .62-.88) (SE 0.45-0.78). In conclusion, poor agreement was demonstrated using current prediction equations in children with chronic conditions. Disease-specific equations and cut points were developed.

  20. Validation of Cut-Points for Evaluating the Intensity of Physical Activity with Accelerometry-Based Mean Amplitude Deviation (MAD).

    PubMed

    Vähä-Ypyä, Henri; Vasankari, Tommi; Husu, Pauliina; Mänttäri, Ari; Vuorimaa, Timo; Suni, Jaana; Sievänen, Harri

    2015-01-01

    Our recent study of three accelerometer brands in various ambulatory activities showed that the mean amplitude deviation (MAD) of the resultant acceleration signal performed best in separating different intensity levels and provided excellent agreement between the three devices. The objective of this study was to derive a regression model that estimates oxygen consumption (VO2) from MAD values and validate the MAD-based cut-points for light, moderate and vigorous locomotion against VO2 within a wide range of speeds. 29 participants performed a pace-conducted non-stop test on a 200 m long indoor track. The initial speed was 0.6 m/s and it was increased by 0.4 m/s every 2.5 minutes until volitional exhaustion. The participants could freely decide whether they preferred to walk or run. During the test they carried a hip-mounted tri-axial accelerometer and mobile metabolic analyzer. The MAD was calculated from the raw acceleration data and compared to directly measured incident VO2. Cut-point between light and moderate activity was set to 3.0 metabolic equivalent (MET, 1 MET = 3.5 ml · kg-1 · min-1) and between moderate and vigorous activity to 6.0 MET as per standard use. The MAD and VO2 showed a very strong association. Within individuals, the range of r values was from 0.927 to 0.991 providing the mean r = 0.969. The optimal MAD cut-point for 3.0 MET was 91 mg (milligravity) and 414 mg for 6.0 MET. The present study showed that the MAD is a valid method in terms of the VO2 within a wide range of ambulatory activities from slow walking to fast running. Being a device-independent trait, the MAD facilitates directly comparable, accurate results on the intensity of physical activity with all accelerometers providing tri-axial raw data.

  1. Prediction of energy expenditure and physical activity in preschoolers.

    PubMed

    Butte, Nancy F; Wong, William W; Lee, Jong Soo; Adolph, Anne L; Puyau, Maurice R; Zakeri, Issa F

    2014-06-01

    Accurate, nonintrusive, and feasible methods are needed to predict energy expenditure (EE) and physical activity (PA) levels in preschoolers. Herein, we validated cross-sectional time series (CSTS) and multivariate adaptive regression splines (MARS) models based on accelerometry and heart rate (HR) for the prediction of EE using room calorimetry and doubly labeled water (DLW) and established accelerometry cut points for PA levels. Fifty preschoolers, mean ± SD age of 4.5 ± 0.8 yr, participated in room calorimetry for minute-by-minute measurements of EE, accelerometer counts (AC) (Actiheart and ActiGraph GT3X+), and HR (Actiheart). Free-living 105 children, ages 4.6 ± 0.9 yr, completed the 7-d DLW procedure while wearing the devices. AC cut points for PA levels were established using smoothing splines and receiver operating characteristic curves. On the basis of calorimetry, mean percent errors for EE were -2.9% ± 10.8% and -1.1% ± 7.4% for CSTS models and -1.9% ± 9.6% and 1.3% ± 8.1% for MARS models using the Actiheart and ActiGraph+HR devices, respectively. On the basis of DLW, mean percent errors were -0.5% ± 9.7% and 4.1% ± 8.5% for CSTS models and 3.2% ± 10.1% and 7.5% ± 10.0% for MARS models using the Actiheart and ActiGraph+HR devices, respectively. Applying activity EE thresholds, final accelerometer cut points were determined: 41, 449, and 1297 cpm for Actiheart x-axis; 820, 3908, and 6112 cpm for ActiGraph vector magnitude; and 240, 2120, and 4450 cpm for ActiGraph x-axis for sedentary/light, light/moderate, and moderate/vigorous PA (MVPA), respectively. On the basis of confusion matrices, correctly classified rates were 81%-83% for sedentary PA, 58%-64% for light PA, and 62%-73% for MVPA. The lack of bias and acceptable limits of agreement affirms the validity of the CSTS and MARS models for the prediction of EE in preschool-aged children. Accelerometer cut points are satisfactory for the classification of sedentary, light, and moderate/vigorous levels of PA in preschoolers.

  2. Accelerometer-based measures in physical activity surveillance: current practices and issues.

    PubMed

    Pedišić, Željko; Bauman, Adrian

    2015-02-01

    Self-reports of physical activity (PA) have been the mainstay of measurement in most non-communicable disease (NCD) surveillance systems. To these, other measures are added to summate to a comprehensive PA surveillance system. Recently, some national NCD surveillance systems have started using accelerometers as a measure of PA. The purpose of this paper was specifically to appraise the suitability and role of accelerometers for population-level PA surveillance. A thorough literature search was conducted to examine aspects of the generalisability, reliability, validity, comprehensiveness and between-study comparability of accelerometer estimates, and to gauge the simplicity, cost-effectiveness, adaptability and sustainability of their use in NCD surveillance. Accelerometer data collected in PA surveillance systems may not provide estimates that are generalisable to the target population. Accelerometer-based estimates have adequate reliability for PA surveillance, but there are still several issues associated with their validity. Accelerometer-based prevalence estimates are largely dependent on the investigators' choice of intensity cut-off points. Maintaining standardised accelerometer data collections in long-term PA surveillance systems is difficult, which may cause discontinuity in time-trend data. The use of accelerometers does not necessarily produce useful between-study and international comparisons due to lack of standardisation of data collection and processing methods. To conclude, it appears that accelerometers still have limitations regarding generalisability, validity, comprehensiveness, simplicity, affordability, adaptability, between-study comparability and sustainability. Therefore, given the current evidence, it seems that the widespread adoption of accelerometers specifically for large-scale PA surveillance systems may be premature. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Evaluation of low-cost, objective instruments for assessing physical activity in 10-11-year-old children.

    PubMed

    Hart, Teresa L; Brusseau, Timothy; Kulinna, Pamela Hodges; McClain, James J; Tudor-Locke, Catrine

    2011-12-01

    This study compared step counts detected by four, low-cost, objective, physical-activity-assessment instruments and evaluated their ability to detect moderate-to-vigorous physical activity (MVPA) compared to the ActiGraph accelerometer (AG). Thirty-six 10-11-year-old children wore the NL-1000, Yamax Digiwalker SW 200, Omron HJ-151, and Walk4Life MVP concurrently with the AG during school hours on a single day. AG MVPA was derived from activity count data using previously validated cut points. Two of the evaluated instruments provided similar group mean MVPA and step counts compared to AG (dependent on cut point). Low-cost instruments may be useful for measurement of both MVPA and steps in children's physical activity interventions and program evaluation.

  4. A universal, accurate intensity-based classification of different physical activities using raw data of accelerometer.

    PubMed

    Vähä-Ypyä, Henri; Vasankari, Tommi; Husu, Pauliina; Suni, Jaana; Sievänen, Harri

    2015-01-01

    Accelerometers are increasingly used for objective assessment of physical activity. However, because of lack of the proprietary analysis algorithms, direct comparisons between accelerometer brands are difficult. In this study, we propose and evaluate open source methods for commensurate assessment of raw accelerometer data irrespective of the brand. Twenty-one participants carried simultaneously three different tri-axial accelerometers on their waist during five different sedentary activities and five different intensity levels of bipedal movement from slow walking to running. Several time and frequency domain traits were calculated from the measured raw data, and their performance in classifying the activities was compared. Of the several traits, the mean amplitude deviation (MAD) provided consistently the best performance in separating the sedentary activities and different speeds of bipedal movement from each other. Most importantly, the universal cut-off limits based on MAD classified sedentary activities and different intensity levels of walking and running equally well for all three accelerometer brands and reached at least 97% sensitivity and specificity in each case. Irrespective of the accelerometer brand, a simply calculable MAD with universal cut-off limits provides a universal method to evaluate physical activity and sedentary behaviour using raw accelerometer data. A broader application of the present approach is expected to render different accelerometer studies directly comparable with each other. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  5. Coal-shale interface detection system

    NASA Technical Reports Server (NTRS)

    Campbell, R. A.; Hudgins, J. L.; Morris, P. W.; Reid, H., Jr.; Zimmerman, J. E. (Inventor)

    1979-01-01

    A coal-shale interface detection system for use with coal cutting equipment consists of a reciprocating hammer on which an accelerometer is mounted to measure the impact of the hammer as it penetrates the ceiling or floor surface of a mine. A pair of reflectometers simultaneously view the same surface. The outputs of the accelerometer and reflectometers are detected and jointly registered to determine when an interface between coal and shale is being cut through.

  6. Coal-shale interface detector

    NASA Technical Reports Server (NTRS)

    Reid, H., Jr. (Inventor)

    1980-01-01

    A coal-shale interface detector for use with coal cutting equipment is described. The detector consists of a reciprocating hammer with an accelerometer to measure the impact of the hammer as it penetrates the ceiling or floor surface of a mine. Additionally, a pair of reflectometers simultaneously view the same surface, and the outputs from the accelerometer and reflectometers are detected and jointly registered to determine when an interface between coal and shale is being cut through.

  7. Coal-shale interface detection

    NASA Technical Reports Server (NTRS)

    Broussard, P. H.; Burch, J. L.; Drost, E. J.; Stein, R. J. (Inventor)

    1979-01-01

    A penetrometer for coal-shale interface detection is presented. It is used with coal cutting equipment consisting of a reciprocating hammer, having an accelerometer mounted thereon to measure the impact of the hammer as it penetrates the ceiling or floor surface of a mine. Additionally, a pair of reflectometers simultaneously view the same surface, and the outputs from the accelerometer and reflectometers are detected and jointly registered to determine when an interface between coal and shale is being cut through.

  8. Differences in daily in-hospital physical activity and geriatric nutritional risk index in older cardiac inpatients: preliminary results.

    PubMed

    Izawa, Kazuhiro P; Watanabe, Satoshi; Oka, Koichiro; Osada, Naohiko; Omiya, Kazuto; Brubaker, Peter H; Shimizu, Hiroyuki

    2014-12-01

    Little is known about the differences in the geriatric nutritional risk index (GNRI) status in older patients and their relationship to accelerometer-derived measures of physical activity (PA) levels. We determined both differences in daily measured PA based on the GNRI and related cut-off values for PA in elderly cardiac inpatients. We divided 235 consecutive elderly cardiac inpatients (mean age 73.6 years, men 70.6%) into four groups by age and GNRI: older-high group, 65-74 years with high GNRI (≥92 points) (n = 111); older-low group, low GNRI (<92 points) (n = 30); very old-high group, ≥75 years with high GNRI (n = 55); and very old-low group with low GNRI (n = 39). Average step count and physical activity energy expenditure (PAEE in kcal) per day for 2 days of these inpatients were assessed by accelerometer and compared between the four groups to determine cut-off values of PA. Step counts and PAEE were significantly lower in the low-GNRI versus high-GNRI groups in the older (2,742.1 vs. 4,198.1 steps, 55.4 vs. 101.3 kcal, P < 0.001), and very old (2,469.6 vs. 3,423.7 steps, 54.5 vs. 79.1 kcal, P < 0.001) cardiac inpatients. Respective cut-off values for step counts and PAEE were 3,017.6 steps/day and 69.4 kcal (P < 0.01) in the older and 2,579.4 steps/day and 58.8 kcal in the very old cardiac inpatients (P < 0.01). Poor nutritional status, as indicated by a low GNRI, may be a useful predictor of step counts and PAEE. The cut-off values determined in this study might be target values to be attained by older cardiac inpatients.

  9. Deriving a GPS Monitoring Time Recommendation for Physical Activity Studies of Adults.

    PubMed

    Holliday, Katelyn M; Howard, Annie Green; Emch, Michael; Rodríguez, Daniel A; Rosamond, Wayne D; Evenson, Kelly R

    2017-05-01

    Determining locations of physical activity (PA) is important for surveillance and intervention development, yet recommendations for using location recording tools like global positioning system (GPS) units are lacking. Specifically, no recommendation exists for the number of days study participants should wear a GPS to reliably estimate PA time spent in locations. This study used data from participants (N = 224, age = 18-85 yr) in five states who concurrently wore an ActiGraph GT1M accelerometer and a Qstarz BT-Q1000X GPS for three consecutive weeks to construct monitoring day recommendations through variance partitioning methods. PA bouts ≥10 min were constructed from accelerometer counts, and the location of GPS points was determined using a hand-coding protocol. Monitoring day recommendations varied by the type of location (e.g., participant homes vs parks) and the intensity of PA bouts considered (low and medium cut point moderate to vigorous PA [MVPA] bouts or high cut point vigorous PA [VPA] bouts). In general, minutes of all PA intensities spent in a given location could be measured with ≥80% reliability using 1-3 d of GPS monitoring for fitness facilities, schools, and footpaths. MVPA bout minutes in parks and roads required longer monitoring periods of 5-12 d. PA in homes and commercial areas required >19 d of monitoring. Twelve days of monitoring was found to reliably estimate minutes in both low and medium threshold MVPA as well as VPA bouts for many important built environment locations that can be targeted to increase PA at the population level. Minutes of PA in the home environment and commercial locations may be best assessed through other means given the lengthy estimated monitoring time required.

  10. Summary report of mission acceleration measurements for Spacehab-01, STS-57 launched 21 June 1993

    NASA Technical Reports Server (NTRS)

    Finley, Brian; Grodsinsky, Carlos; Delombard, Richard

    1994-01-01

    The maiden voyage of the commercial Spacehab laboratory module onboard the STS-57 mission was integrated with several accelerometer packages, one of which was the Space Acceleration Measurement System (SAMS). The June 21st 1993, launch was the seventh successful mission for the Office of Life and Microgravity Sciences and Application's (OLMSA) SAMS unit. This flight was also complemented by a second accelerometer system. The Three Dimensional Microgravity Accelerometer (3-DMA), a Code C funded acceleration measurement system, offering an on-orbit residual calibration as a reference for the unit's four triaxial accelerometers. The SAMS accelerometer unit utilized three remote triaxial sensor heads mounted on the forward Spacehab module bulkhead and on one centrally located experiment locker door. These triaxial heads had filter cut-offs set to 5, 50, and 1000 Hz. The mission also included other experiment specific accelerometer packages in various locations.

  11. Cut-off values for classifying active children and adolescentes using the Physical Activity Questionnaire: PAQ-C and PAQ-ACut-off values for classifying active children and adolescents using the Physical Activity Questionnaire: PAQ-C and PAQ-A.

    PubMed

    Benítez-Porres, Javier; Alvero-Cruz, José Ramón; Sardinha, Luis B; López-Fernández, Iván; Carnero, Elvis A

    2016-09-20

    The Physical Activity Questionnaire for children and adolescents (PAQ-C & PAQ-A) has been widely used in research and field settings. However, there is a lack of information about its final score meaning. To determine PAQ-C and PAQ-A score cut-off values using physical activity (PA) thresholds objectively measured as reference criteria. 146 children (n = 83 boys, n = 63 girls) and 234 adolescents (n = 115 boys, n = 119 girls) participated in this study. Accelerometers (Actigraph GT3X) were used to assess objectively PA during one-week, afterwards PAQ was filled by the participants. As participants met or not the international PA recommendations for total, moderate-vigorous (MVPA) or light PA, three categorical variables of two levels were created. ROC curves procedure were carried out to obtain score cut-off points for identifying the positive category recommendation. ROC curves analysis estimated 2.75 and 2.73 score cut-off points to discriminate > 60 minutes of MVPA for PAQ-A and PAQ-C respectively (PAQ-A AUC = 0.68, p < 0.001 and PAQ-C; AUC = 0.55, p > 0.05). Also 60 minutes of MVPA was achieved with a total volume of 10,664 steps/day in children and 9,701 steps/day in adolescents. Our results suggest that PAQ-A can be a useful tool to classify adolescents as active or inactive following international recommendations as criteria. However, we could not find a significant cut-off for PAQ-C score.

  12. ExFiT Flight Design and Structural Modeling for FalconLAUNCH VIII Sounding Rocket

    DTIC Science & Technology

    2010-03-01

    frequencies of the test specimen. Next, the accelerometers were placed along the trailing edge of both the main wing and winglet sections. In the first...once again used however, the accelerometer originally in the winglet section was moved to the cut out portion of the main wing section. In this test...the part was struck on the joining section of the specimen connecting both main wing and winglet sections. Finally, the ping hammer was loaded with a

  13. Development of sensitized pick coal interface detector system

    NASA Technical Reports Server (NTRS)

    Burchill, R. F.

    1979-01-01

    One approach for detection of the coal interface is measurement of the pick cutting hoads and shock through the use of pick strain gage load cells and accelerometers. The cutting drum of a long wall mining machine contains a number of cutting picks. In order to measure pick loads and shocks, one pick was instrumented and telementry used to transmit the signals from the drum to an instrument-type tape recorder. A data system using FM telemetry was designed to transfer cutting bit load and shock information from the drum of a longwall shearer coal mining machine to a chassis mounted data recorder.

  14. Application of inertial instruments for DSN antenna pointing and tracking

    NASA Technical Reports Server (NTRS)

    Eldred, D. B.; Nerheim, N. M.; Holmes, K. G.

    1990-01-01

    The feasibility of using inertial instruments to determine the pointing attitude of the NASA Deep Space Network antennas is examined. The objective is to obtain 1 mdeg pointing knowledge in both blind pointing and tracking modes to facilitate operation of the Deep Space Network 70 m antennas at 32 GHz. A measurement system employing accelerometers, an inclinometer, and optical gyroscopes is proposed. The initial pointing attitude is established by determining the direction of the local gravity vector using the accelerometers and the inclinometer, and the Earth's spin axis using the gyroscopes. Pointing during long-term tracking is maintained by integrating the gyroscope rates and augmenting these measurements with knowledge of the local gravity vector. A minimum-variance estimator is used to combine measurements to obtain the antenna pointing attitude. A key feature of the algorithm is its ability to recalibrate accelerometer parameters during operation. A survey of available inertial instrument technologies is also given.

  15. The validity and reliability of a home environment preschool-age physical activity questionnaire (Pre-PAQ)

    PubMed Central

    2011-01-01

    Background There is a need for valid population level measures of physical activity in young children. The aim of this paper is to report the development, and the reliability and validity, of the Preschool-age Children's Physical Activity Questionnaire (Pre-PAQ) which was designed to measure activity of preschool-age children in the home environment in population studies. Methods Pre-PAQ was completed by 103 families, and validated against accelerometry for 67 children (mean age 3.8 years, SD 0.74; males 53%). Pre-PAQ categorizes activity into five progressive levels (stationary no movement, stationary with limb or trunk movement, slow, medium, or fast-paced activity). Pre-PAQ Levels 1-2 (stationary activities) were combined for analyses. Accelerometer data were categorized for stationary, sedentary (SED), non-sedentary (non-SED), light (LPA), moderate (MPA) and vigorous (VPA) physical activity using manufacturer's advice (stationary) or the cut-points described by Sirard et al and Reilly et al. Bland-Altman methods were used to assess agreement between the questionnaire and the accelerometer measures for corresponding activity levels. Reliability of the Pre-PAQ over one week was determined using intraclass correlations (ICC) or kappa (κ) values and percentage of agreement of responses between the two questionnaire administrations. Results Pre-PAQ had good agreement with LPA (mean difference 1.9 mins.day-1) and VPA (mean difference -4.8 mins.day-1), was adequate for stationary activity (mean difference 7.6 mins.day-1) and poor for sedentary activity, whether defined using the cut-points of Sirard et al (mean difference -235.4 mins.day-1) or Reilly et al (mean difference -208.6 mins.day-1) cut-points. Mean difference between the measures for total activity (i.e. Reilly's non-sedentary or Sirard's LMVPA) was 20.9 mins.day-1 and 45.2 mins.day-1. The limits of agreement were wide for all categories. The reliability of Pre-PAQ question responses ranged from 0.31-1.00 (ICC (2, 1)) for continuous measures and 0.60-0.97 (κ) for categorical measures. Conclusions Pre-PAQ has acceptable validity and reliability and appears promising as a population measure of activity behavior but it requires further testing on a more broadly representative population to affirm this. Pre-PAQ fills an important niche for researchers to measure activity in preschool-age children and concurrently to measure parental, family and neighborhood factors that influence these behaviors. PMID:21813025

  16. The validity and reliability of a home environment preschool-age physical activity questionnaire (Pre-PAQ).

    PubMed

    Dwyer, Genevieve M; Hardy, Louise L; Peat, Jennifer K; Baur, Louise A

    2011-08-04

    There is a need for valid population level measures of physical activity in young children. The aim of this paper is to report the development, and the reliability and validity, of the Preschool-age Children's Physical Activity Questionnaire (Pre-PAQ) which was designed to measure activity of preschool-age children in the home environment in population studies. Pre-PAQ was completed by 103 families, and validated against accelerometry for 67 children (mean age 3.8 years, SD 0.74; males 53%). Pre-PAQ categorizes activity into five progressive levels (stationary no movement, stationary with limb or trunk movement, slow, medium, or fast-paced activity). Pre-PAQ Levels 1-2 (stationary activities) were combined for analyses. Accelerometer data were categorized for stationary, sedentary (SED), non-sedentary (non-SED), light (LPA), moderate (MPA) and vigorous (VPA) physical activity using manufacturer's advice (stationary) or the cut-points described by Sirard et al and Reilly et al. Bland-Altman methods were used to assess agreement between the questionnaire and the accelerometer measures for corresponding activity levels. Reliability of the Pre-PAQ over one week was determined using intraclass correlations (ICC) or kappa (κ) values and percentage of agreement of responses between the two questionnaire administrations. Pre-PAQ had good agreement with LPA (mean difference 1.9 mins.day⁻¹) and VPA (mean difference -4.8 mins.day⁻¹), was adequate for stationary activity (mean difference 7.6 mins.day⁻¹) and poor for sedentary activity, whether defined using the cut-points of Sirard et al (mean difference -235.4 mins.day⁻¹) or Reilly et al (mean difference -208.6 mins.day⁻¹) cut-points. Mean difference between the measures for total activity (i.e. Reilly's non-sedentary or Sirard's LMVPA) was 20.9 mins.day⁻¹ and 45.2 mins.day⁻¹. The limits of agreement were wide for all categories. The reliability of Pre-PAQ question responses ranged from 0.31-1.00 (ICC (2, 1)) for continuous measures and 0.60-0.97 (κ) for categorical measures. Pre-PAQ has acceptable validity and reliability and appears promising as a population measure of activity behavior but it requires further testing on a more broadly representative population to affirm this. Pre-PAQ fills an important niche for researchers to measure activity in preschool-age children and concurrently to measure parental, family and neighborhood factors that influence these behaviors.

  17. Diagnostics of flexible workpiece using acoustic emission, acceleration and eddy current sensors in milling operation

    NASA Astrophysics Data System (ADS)

    Filippov, A. V.; Tarasov, S. Yu.; Filippova, E. O.; Chazov, P. A.; Shamarin, N. N.; Podgornykh, O. A.

    2016-11-01

    Monitoring of the edge clamped workpiece deflection during milling has been carried our using acoustic emission, accelerometer and eddy current sensors. Such a monitoring is necessary in precision machining of vital parts used in air-space engineering where a majority of them made by milling. The applicability of the AE, accelerometers and eddy current sensors has been discussed together with the analysis of measurement errors. The appropriate sensor installation diagram has been proposed for measuring the workpiece elastic deflection exerted by the cutting force.

  18. Intensity Classification Accuracy of Accelerometer-Measured Physical Activities in Chinese Children and Youth

    ERIC Educational Resources Information Center

    Zhu, Zheng; Chen, Peijie; Zhuang, Jie

    2013-01-01

    Purpose: Many ActiGraph accelerometer cutoff points and equations have been developed to classify children and youth's physical activity (PA) into different intensity levels. Using a sample from the Chinese City Children and Youth Physical Activity Study, this study was to develop new ActiGraph cutoff points for moderate-to-vigorous physical…

  19. Self-Reported Versus Accelerometer-Assessed Daily Physical Activity in Childhood Obesity Treatment.

    PubMed

    Schnurr, Theresia M; Bech, Bianca; Nielsen, Tenna R H; Andersen, Ida G; Hjorth, Mads F; Aadahl, Mette; Fonvig, Cilius E; Hansen, Torben; Holm, Jens-Christian

    2017-08-01

    We investigated the relationship between interview-based subjective ratings of physical activity (PA) engagement and accelerometer-assessed objectively measured PA in children and adolescents with overweight or obesity. A total of 92 children and adolescents (40 males, 52 females) with BMI ≥ 90th percentile for sex and age, aged 5-17 years had valid GT3X + accelerometer-assessed PA and interview-assessed self-reported information on PA engagement at the time of enrollment in a multidisciplinary outpatient tertiary treatment for childhood obesity. Accelerometer-derived mean overall PA and time spent in moderate to vigorous physical intensity were generated, applying cut-offs based on Vector Magnitude settings as defined by Romanzini et al. (2014), and a physical activity score (PAS) based on self-reported data. Overall, a higher self-reported PAS was correlated with higher accelerometer-assessed daily total PA levels ( r = 0.34, p < .01) and children who reported a high PAS were more physically active compared with children who reported a low PAS. There was a fair level of agreement between self-reported PAS and accelerometer-assessed PA (Kappa agreement = 0.23; 95% CI = [0.03, 0.43]; p = .01). PAS, derived from self-report, may be a useful instrument for evaluating PA at a group level among children and adolescents enrolled in multidisciplinary obesity treatment.

  20. Study protocol of physical activity and sedentary behaviour measurement among schoolchildren by accelerometry--cross-sectional survey as part of the ENERGY-project.

    PubMed

    Yıldırım, Mine; Verloigne, Maïté; de Bourdeaudhuij, Ilse; Androutsos, Odysseas; Manios, Yannis; Felso, Regina; Kovács, Éva; Doessegger, Alain; Bringolf-Isler, Bettina; te Velde, Saskia J; Brug, Johannes; Chinapaw, Mai J M

    2011-03-25

    Physical activity and sedentary behaviour among children should be measured accurately in order to investigate their relationship with health. Accelerometry provides objective and accurate measurement of body movement, which can be converted to meaningful behavioural outcomes. The aim of this study was to evaluate the best evidence for the decisions on data collection and data processing with accelerometers among children resulting in a standardized protocol for use in the participating countries. This cross-sectional accelerometer study was conducted as part of the European ENERGY-project that aimed to produce an obesity prevention intervention among schoolchildren. Five countries, namely Belgium, Greece, Hungary, Switzerland and the Netherlands participated in the accelerometer study. We used three different Actigraph models--Actitrainers (triaxial), GT3Xs and GT1Ms. Children wore the device for six consecutive days including two weekend days. We selected an epoch length of 15 seconds. Accelerometers were placed at children's waist at the right side of the body in an elastic belt. In total, 1082 children participated in the study (mean age = 11.7 ± 0.75 y, 51% girls). Non-wearing time was calculated as periods of more than 20 minutes of consecutive zero counts. The minimum daily wearing time was set to 10 hours for weekdays and 8 hours for weekend days. The inclusion criterion for further analysis was having at least three valid weekdays and one valid weekend day. We selected a cut-point (count per minute (cpm)) of <100 cpm for sedentary behaviour, <3000 cpm for light, <5200 cpm for moderate, and >5200 cpm for vigorous physical activity. We also created time filters for school-time during data cleaning in order to explore school-time physical activity and sedentary behaviour patterns in particular. This paper describes the decisions for data collection and processing. Use of standardized protocols would ease future use of accelerometry and the comparability of results between studies.

  1. Comparison of FRF measurements and mode shapes determined using optically image based, laser, and accelerometer measurements

    NASA Astrophysics Data System (ADS)

    Warren, Christopher; Niezrecki, Christopher; Avitabile, Peter; Pingle, Pawan

    2011-08-01

    Today, accelerometers and laser Doppler vibrometers are widely accepted as valid measurement tools for structural dynamic measurements. However, limitations of these transducers prevent the accurate measurement of some phenomena. For example, accelerometers typically measure motion at a limited number of discrete points and can mass load a structure. Scanning laser vibrometers have a very wide frequency range and can measure many points without mass-loading, but are sensitive to large displacements and can have lengthy acquisition times due to sequential measurements. Image-based stereo-photogrammetry techniques provide additional measurement capabilities that compliment the current array of measurement systems by providing an alternative that favors high-displacement and low-frequency vibrations typically difficult to measure with accelerometers and laser vibrometers. Within this paper, digital image correlation, three-dimensional (3D) point-tracking, 3D laser vibrometry, and accelerometer measurements are all used to measure the dynamics of a structure to compare each of the techniques. Each approach has its benefits and drawbacks, so comparative measurements are made using these approaches to show some of the strengths and weaknesses of each technique. Additionally, the displacements determined using 3D point-tracking are used to calculate frequency response functions, from which mode shapes are extracted. The image-based frequency response functions (FRFs) are compared to those obtained by collocated accelerometers. Extracted mode shapes are then compared to those of a previously validated finite element model (FEM) of the test structure and are shown to have excellent agreement between the FEM and the conventional measurement approaches when compared using the Modal Assurance Criterion (MAC) and Pseudo-Orthogonality Check (POC).

  2. Accelerometer Method and Apparatus for Integral Display and Control Functions

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1996-01-01

    Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. Art accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.

  3. Accelerometer Method and Apparatus for Integral Display and Control Functions

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1998-01-01

    Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto is discussed. An accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.

  4. A Descriptive Study of Objectively Measured Pokémon GO Playtime in College Students.

    PubMed

    Fountaine, Charles J; Springer, Emily J; Sward, Jasmine R

    2018-01-01

    Since its debut in July 2016, Pokémon GO has been a wildly popular mobile gaming app. In contrast to many previous apps, Pokémon GO requires the user to be physically active. However, the extent to which Pokémon GO contributes to physical activity is unknown. Therefore, the purpose of this study was to investigate the physical activity profile of playing Pokémon GO for 60 minutes in recreationally active college students. College students (n=27, n=19 female) were fitted with an accelerometer, pedometer, and heart rate monitor to assess the activity demands during a 60-min bout of Pokémon GO. Troiano accelerometer cut points were utilized to estimate time spent in sedentary, light, moderate, and vigorous-intensity physical activity. Of the 60-min allotted playtime, accelerometry indicated 82% was achieved via moderate-to vigorous-intensity physical activity. Pedometer counts indicated approximately 6000-steps/100-steps/min, indicative of moderate-intensity physical activity. Heart rates were approximately 50% of age-predicted maximum, also indicative of moderate-intensity physical activity. The results of this study provide evidence that playing one hour of Pokémon GO can be an effective means of accumulating recommended levels of daily/weekly physical activity.

  5. A Descriptive Study of Objectively Measured Pokémon GO Playtime in College Students

    PubMed Central

    FOUNTAINE, CHARLES J.; SPRINGER, EMILY J.; SWARD, JASMINE R.

    2018-01-01

    Since its debut in July 2016, Pokémon GO has been a wildly popular mobile gaming app. In contrast to many previous apps, Pokémon GO requires the user to be physically active. However, the extent to which Pokémon GO contributes to physical activity is unknown. Therefore, the purpose of this study was to investigate the physical activity profile of playing Pokémon GO for 60 minutes in recreationally active college students. College students (n=27, n=19 female) were fitted with an accelerometer, pedometer, and heart rate monitor to assess the activity demands during a 60-min bout of Pokémon GO. Troiano accelerometer cut points were utilized to estimate time spent in sedentary, light, moderate, and vigorous-intensity physical activity. Of the 60-min allotted playtime, accelerometry indicated 82% was achieved via moderate-to vigorous-intensity physical activity. Pedometer counts indicated approximately 6000-steps/100-steps/min, indicative of moderate-intensity physical activity. Heart rates were approximately 50% of age-predicted maximum, also indicative of moderate-intensity physical activity. The results of this study provide evidence that playing one hour of Pokémon GO can be an effective means of accumulating recommended levels of daily/weekly physical activity. PMID:29541340

  6. Experiment on interface separation detection of concrete-filled steel tubular arch bridge using accelerometer array

    NASA Astrophysics Data System (ADS)

    Pan, Shengshan; Zhao, Xuefeng; Zhao, Hailiang; Mao, Jian

    2015-04-01

    Based on the vibration testing principle, and taking the local vibration of steel tube at the interface separation area as the study object, a real-time monitoring and the damage detection method of the interface separation of concrete-filled steel tube by accelerometer array through quantitative transient self-excitation is proposed. The accelerometers are arranged on the steel tube area with or without void respectively, and the signals of accelerometers are collected at the same time and compared under different transient excitation points. The results show that compared with the signal of compact area, the peak value of accelerometer signal at void area increases and attenuation speed slows down obviously, and the spectrum peaks of the void area are much more and disordered and the amplitude increases obviously. whether the input point of transient excitation is on void area or not is irrelevant with qualitative identification results. So the qualitative identification of the interface separation of concrete-filled steel tube based on the signal of acceleration transducer is feasible and valid.

  7. Linear Controller Design: Limits of Performance

    DTIC Science & Technology

    1991-01-01

    where a sensor should be placed eg where an accelerometer is to be positioned on an aircraft or where a strain gauge is placed along a beam The...309 VIII CONTENTS 14 Special Algorithms for Convex Optimization 311 Notation and Problem Denitions...311 On Algorithms for Convex Optimization 312 CuttingPlane Algorithms

  8. Validation of the human activity profile questionnaire as a measure of physical activity levels in older community-dwelling women.

    PubMed

    Bastone, Alessandra de Carvalho; Moreira, Bruno de Souza; Vieira, Renata Alvarenga; Kirkwood, Renata Noce; Dias, João Marcos Domingues; Dias, Rosângela Corrêa

    2014-07-01

    The purpose of this study was to assess the validity of the Human Activity Profile (HAP) by comparing scores with accelerometer data and by objectively testing its cutoff points. This study included 120 older women (age 60-90 years). Average daily time spent in sedentary, moderate, and hard activity; counts; number of steps; and energy expenditure were measured using an accelerometer. Spearman rank order correlations were used to evaluate the correlation between the HAP scores and accelerometer variables. Significant relationships were detected (rho = .47-.75, p < .001), indicating that the HAP estimates physical activity at a group level well; however, scatterplots showed individual errors. Receiver operating characteristic curves were constructed to determine HAP cutoff points on the basis of physical activity level recommendations, and the cutoff points found were similar to the original HAP cutoff points. The HAP is a useful indicator of physical activity levels in older women.

  9. Design, Simulation and Fabrication of Triaxial MEMS High Shock Accelerometer.

    PubMed

    Zhang, Zhenhai; Shi, Zhiguo; Yang, Zhan; Xie, Zhihong; Zhang, Donghong; Cai, De; Li, Kejie; Shen, Yajing

    2015-04-01

    On the basis of analyzing the disadvantage of other structural accelerometer, three-axis high g MEMS piezoresistive accelerometer was put forward in order to apply to the high-shock test field. The accelerometer's structure and working principle were discussed in details. The simulation results show that three-axis high shock MEMS accelerometer can bear high shock. After bearing high shock impact in high-shock shooting test, three-axis high shock MEMS accelerometer can obtain the intact metrical information of the penetration process and still guarantee the accurate precision of measurement in high shock load range, so we can not only analyze the law of stress wave spreading and the penetration rule of the penetration process of the body of the missile, but also furnish the testing technology of the burst point controlling. The accelerometer has far-ranging application in recording the typical data that projectile penetrating hard target and furnish both technology guarantees for penetration rule and defend engineering.

  10. The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running

    PubMed Central

    Kiesewetter, Pierre; Milani, Thomas L.

    2018-01-01

    Previous studies have used accelerometers with various operating ranges (ORs) when measuring biomechanical parameters. However, it is still unclear whether ORs influence the accuracy of running parameters, and whether the different stiffnesses of footwear midsoles influence this accuracy. The purpose of the present study was to systematically investigate the influence of OR on the accuracy of stride length, running velocity, and on peak tibial acceleration. Twenty-one recreational heel strike runners ran on a 15-m indoor track at self-selected running speeds in three footwear conditions (low to high midsole stiffness). Runners were equipped with an inertial measurement unit (IMU) affixed to the heel cup of the right shoe and with a uniaxial accelerometer at the right tibia. Accelerometers (at the tibia and included in the IMU) with a high OR of ±70 g were used as the reference and the data were cut at ±32, ±16, and at ±8 g in post-processing, before calculating parameters. The results show that the OR influenced the outcomes of all investigated parameters, which were not influenced by tested footwear conditions. The lower ORs were associated with an underestimation error for all biomechanical parameters, which increased noticeably with a decreasing OR. It can be concluded that accelerometers with a minimum OR of ±32 g should be used to avoid inaccurate measurements. PMID:29303986

  11. Comparison of modal test results - Multipoint sine versus single-point random. [for Mariner Jupiter/Saturn spacecraft

    NASA Technical Reports Server (NTRS)

    Leppert, E. L.; Lee, S. H.; Day, F. D.; Chapman, P. C.; Wada, B. K.

    1976-01-01

    The Mariner Jupiter/Saturn (MJS) spacecraft was subjected to the traditional multipoint sine dwell (MPSD) modal test using 111 accelerometer channels, and also to single-point random (SPR) testing using 26 accelerometer channels, and the two methods are compared according to cost, schedule, and technical criteria. A measure of comparison between the systems was devised in terms of the cumulative difference in the kinetic energy distribution of the common accelerometers. The SPR and MPSD method show acceptable agreement with respect to frequencies and mode damping. The merit of the SPR method is that the excitation points are minimized and the test article can be committed to other uses while data analysis is performed. The MPSD approach allows validity of the data to be determined as the test progresses. Costs are about the same for the two methods.

  12. Summary Report of Mission Acceleration Measurements for STS-62, Launched 4 March 1994

    NASA Technical Reports Server (NTRS)

    Rogers, Melissa J. B.; Delombard, Richard

    1994-01-01

    The second mission of the United States Microgravity Payload on-board the STS-62 mission was supported with three accelerometer instruments: the Orbital Acceleration Research Experiment (OARE) and two units of the Space Acceleration Measurements System (SAMS). The March 4, 1994 launch was the fourth successful mission for OARE and the ninth successful mission for SAMS. The OARE instrument utilizes a sensor for very low frequency measurements below one Hertz. The accelerations in this frequency range are typically referred to as quasisteady accelerations. One of the SAMS units had two remote triaxial sensor heads mounted on the forward MPESS structure between two furnance experiments, MEPHISTO and AADSF. These triaxial heads had low-pass filter cut-off frequencies at 10 and 25 Hz. The other SAMS unit utilized three remote triaxial sensor heads. Two of the sensor heads were mounted on the aft MPESS structure between the two experiments IDGE and ZENO. These triaxial heads had low-pass filter cut-off frequencies at 10 and 25 Hz. The third sensor head was mounted on the thermostat housing inside the IDGE experiment container. This triaxial head had a low-pass filter cut-off frequency at 5 Hz. This report is prepared to furnish interested experiment investigators with a guide to evaluating the acceleration environment during STS-62 and as a means of identifying areas which require further study. To achieve this purpose, various pieces of information are included, such as an overview of the STS-62 mission, a description of the accelerometer system flown on STS-62, some specific analysis of the accelerometer data in relation to the various mission activities, and an overview of the low-gravity environment during the entire mission. An evaluation form is included at the end of the report to solicit users' comments about the usefulness of this series of reports.

  13. Development of sensitized pick coal interface detector system

    NASA Technical Reports Server (NTRS)

    Burchill, R. F.

    1982-01-01

    One approach for detection of the coal interface is measurement of pick cutting loads and shock through the use of pick strain gage load cells and accelerometers. The cutting drum of a long wall mining machine contains a number of cutting picks. In order to measure pick loads and shocks, one pick was instrumented and telemetry used to transmit the signals from the drum to an instrument-type tape recorder. A data system using FM telemetry was designed to transfer cutting bit load and shock information from the drum of a longwall shearer coal mining machine to a chassis mounted data recorder. The design of components in the test data system were finalized, the required instruments were assembled, the instrument system was evaluated in an above-ground simulation test, and an underground test series to obtain tape recorded sensor data was conducted.

  14. Prospective associations between physical activity and obesity among adolescent girls: racial differences and implications for prevention.

    PubMed

    White, James; Jago, Russell

    2012-06-01

    To test for differences in prospective associations between physical activity and obesity among black and white adolescent girls. Prospective cohort study using data from the National Heart, Lung, and Blood Institute Growth and Health Study. SETTING Multicenter study at the University of California (Berkeley), Children's Medical Center at the University of Cincinnati (Cincinnati, Ohio), and Westat, Inc, and Group Health Association (Rockville, Maryland). A total of 1148 adolescent girls (538 black and 610 white) who provided valid data on levels of physical activity and obesity at ages 12 and 14 years. Physical activity, assessed as accelerometer counts per day. Three measurements of obesity were obtained using the Centers for Disease Control and Prevention definition of obesity (at or above the age-specific 95th percentile of body mass index), the International Obesity Task Force reference body mass index cut points for obesity in children, and the sums of skinfold thickness (with the cohort ≥90th percentile as indicative of obesity). We found a strong negative dose-response association between quartiles of accelerometer counts per day at age 12 years and obesity at age 14 years (using all 3 measurements of obesity) in white but not black girls (P < .001 for body mass index interaction and P = .06 for sums of skinfold thickness interaction). The odds ratios for obesity (using the cohort ≥90th percentile for sums of skinfold thickness) in adjusted models between the top and the bottom quartiles of accelerometer counts per day were 0.15 (95% CI, 0.04-0.63; P = .03 for trend) in white girls and 0.85 (95% CI, 0.32-2.26; P = .93 for trend) in black girls. Higher levels of physical activity are prospectively associated with lower levels of obesity in white adolescent girls but not in black adolescent girls. Obesity prevention interventions may need to be adapted to account for the finding that black girls are less sensitive to the effects of physical activity.

  15. Comparison of four Fitbit and Jawbone activity monitors with a research-grade ActiGraph accelerometer for estimating physical activity and energy expenditure.

    PubMed

    Imboden, Mary T; Nelson, Michael B; Kaminsky, Leonard A; Montoye, Alexander Hk

    2017-05-08

    Consumer-based physical activity (PA) monitors have become popular tools to track PA behaviours. Currently, little is known about the validity of the measurements provided by consumer monitors. We aimed to compare measures of steps, energy expenditure (EE) and active minutes of four consumer monitors with one research-grade accelerometer within a semistructured protocol. Thirty men and women (18-80 years old) wore Fitbit One (worn at the waist), Fitbit Zip (waist), Fitbit Flex (wrist), Jawbone UP24 (wrist) and one waist-worn research-grade accelerometer (ActiGraph) while participating in an 80 min protocol. A validated EE prediction equation and active minute cut-points were applied to ActiGraph data. Criterion measures were assessed using direct observation (step count) and portable metabolic analyser (EE, active minutes). A repeated measures analysis of variance (ANOVA) was used to compare differences between consumer monitors, ActiGraph, and criterion measures. Similarly, a repeated measures ANOVA was applied to a subgroup of subjects who didn't cycle. Participants took 3321±571 steps, had 28±6 active min and expended 294±56 kcal based on criterion measures. Comparatively, all monitors underestimated steps and EE by 13%-32% (p<0.01); additionally the Fitbit Flex, UP24, and ActiGraph underestimated active minutes by 35%-65% (p<0.05). Underestimations of PA and EE variables were found to be similar in the subgroup analysis. Consumer monitors had similar accuracy for PA assessment as the ActiGraph, which suggests that consumer monitors may serve to track personal PA behaviours and EE. However, due to discrepancies among monitors, individuals should be cautious when comparing relative and absolute differences in PA values obtained using different monitors. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Calibration of raw accelerometer data to measure physical activity: A systematic review.

    PubMed

    de Almeida Mendes, Márcio; da Silva, Inácio C M; Ramires, Virgílio V; Reichert, Felipe F; Martins, Rafaela C; Tomasi, Elaine

    2018-03-01

    Most of calibration studies based on accelerometry were developed using count-based analyses. In contrast, calibration studies based on raw acceleration signals are relatively recent and their evidences are incipient. The aim of the current study was to systematically review the literature in order to summarize methodological characteristics and results from raw data calibration studies. The review was conducted up to May 2017 using four databases: PubMed, Scopus, SPORTDiscus and Web of Science. Methodological quality of the included studies was evaluated using the Landis and Koch's guidelines. Initially, 1669 titles were identified and, after assessing titles, abstracts and full-articles, 20 studies were included. All studies were conducted in high-income countries, most of them with relatively small samples and specific population groups. Physical activity protocols were different among studies and the indirect calorimetry was the criterion measure mostly used. High mean values of sensitivity, specificity and accuracy from the intensity thresholds of cut-point-based studies were observed (93.7%, 91.9% and 95.8%, respectively). The most frequent statistical approach applied was machine learning-based modelling, in which the mean coefficient of determination was 0.70 to predict physical activity energy expenditure. Regarding the recognition of physical activity types, the mean values of accuracy for sedentary, household and locomotive activities were 82.9%, 55.4% and 89.7%, respectively. In conclusion, considering the construct of physical activity that each approach assesses, linear regression, machine-learning and cut-point-based approaches presented promising validity parameters. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Decision-Making Influences Tibial Impact Accelerations During Lateral Cutting.

    PubMed

    Lucas, Logan A; England, Benjamin S; Mason, Travis W; Lanning, Christopher R; Miller, Taylor M; Morgan, Alexander M; Almonroeder, Thomas G

    2018-05-29

    Lower extremity musculoskeletal injuries are common in sports such as basketball and soccer. Athletes competing in sports of this nature must maneuver in response to the actions of their teammates, opponents, etc. This limits their ability to pre-plan movements. The purpose of this study was to compare impact accelerations during pre-planned vs. un-planned lateral cutting. Thirty subjects (15 males, 15 females) performed pre-planned and un-planned cuts while we analyzed impact accelerations using an accelerometer secured to their tibia. For the pre-planned condition, subjects were aware of the movement to perform before initiating a trial. For the un-planned condition, subjects initiated their movement and then reacted to the illumination of one of three visual stimuli which dictated whether they would cut, land, or land-and-jump. A mixed-model ANOVA with a between factor of sex (male, female) and a within factor of condition (pre-planned, un-planned) was used to analyze the magnitude and variability of the impact accelerations for the cutting trials. Both males and females demonstrated higher impact accelerations (p = .010) and a trend toward greater inter-trial variability (p = .073) for the un-planned cutting trials (vs. pre-planned cuts). Un-planned cutting may place greater demands on the musculoskeletal system.

  18. Cut points on 0-10 numeric rating scales for symptoms included in the Edmonton Symptom Assessment Scale in cancer patients: a systematic review.

    PubMed

    Oldenmenger, Wendy H; de Raaf, Pleun J; de Klerk, Cora; van der Rijt, Carin C D

    2013-06-01

    To improve the management of cancer-related symptoms, systematic screening is necessary, often performed by using 0-10 numeric rating scales. Cut points are used to determine if scores represent clinically relevant burden. The aim of this systematic review was to explore the evidence on cut points for the symptoms of the Edmonton Symptom Assessment Scale. Relevant literature was searched in PubMed, CINAHL®, Embase, and PsycINFO®. We defined a cut point as the lower bound of the scores representing moderate or severe burden. Eighteen articles were eligible for this review. Cut points were determined using the interference with daily life, another symptom-related method, or a verbal scale. For pain, cut point 5 and, to a lesser extent, cut point 7 were found as the optimal cut points for moderate pain and severe pain, respectively. For moderate tiredness, the best cut point seemed to be cut point 4. For severe tiredness, both cut points 7 and 8 were suggested frequently. A lack of evidence exists for nausea, depression, anxiety, drowsiness, appetite, well-being, and shortness of breath. Few studies suggested a cut point below 4. For many symptoms, there is no clear evidence as to what the optimal cut points are. In daily clinical practice, a symptom score ≥4 is recommended as a trigger for a more comprehensive symptom assessment. Until there is more evidence on the optimal cut points, we should hold back using a certain cut point in quality indicators and be cautious about strongly recommending a certain cut point in guidelines. Copyright © 2013 U.S. Cancer Pain Relief Committee. Published by Elsevier Inc. All rights reserved.

  19. Physical activity levels among children attending family day care.

    PubMed

    Rice, Kelly R; Trost, Stewart G

    2014-01-01

    To objectively measure the physical activity (PA) levels of children attending family day care programs. A total of 114 children from 47 family day care centers wore an accelerometer for the duration of their time in care. Time in moderate-to-vigorous PA (MVPA) and total PA was calculated using previously validated cut points. Children accumulated 5.8 ± 3.2 minutes of MVPA and 10.4 ± 4.4 minutes of total PA per hour of attendance. Boys exhibited significantly higher levels of PA than girls. Among healthy weight children, 4- and 5-year-olds exhibited significantly higher levels of PA than 2- and 3-year-olds. Overweight and obese 4- and 5-year-olds exhibited significantly lower levels of PA than their healthy weight counterparts. Children attending family day care participate in low levels of PA during the child care day. The results highlight the need for effective programs to promote PA in family day care. Copyright © 2014 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  20. Accuracy improvement in a calibration test bench for accelerometers by a vision system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D’Emilia, Giulio, E-mail: giulio.demilia@univaq.it; Di Gasbarro, David, E-mail: david.digasbarro@graduate.univaq.it; Gaspari, Antonella, E-mail: antonella.gaspari@graduate.univaq.it

    2016-06-28

    A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behaviormore » if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.« less

  1. Microseismic Monitoring of the Mounds Drill Cuttings Injection Tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Branagan, P.T.; Mahrer, K.D.; Moschovidis, Z.A.

    This paper describes the microseismic mapping of repeated injections of drill cuttings into two separate formations at a test site near Mounds, OK. Injections were performed in sandstone and shale formations at depths of 830 and 595 m, respectively. Typical injection disposal was simulated using multiple small-volume injections over a three-day period, with long shut-in periods interspersed between the injections. Microseismic monitoring was achieved using a 5-level array of wireline-run, triaxial- accelerometer receivers in a monitor well 76 m from the disposed well. Results of the mapped microseismic locations showed that the disposal domti W= generally aligns with the majormore » horizontal stress with some variations in azimuth and that wide variations in height and length growth occurred with continued injections. These experiments show that the cuttings injection process cm be adequately monitored from a downhole, wireline-run receiver array, thus providing process control and environmental assurance.« less

  2. Accelerometer output and its association with energy expenditure during manual wheelchair propulsion.

    PubMed

    Learmonth, Y C; Kinnett-Hopkins, D; Rice, I M; Dysterheft, J L; Motl, R W

    2016-02-01

    This is an experimental design. This study examined the association between rates of energy expenditure (that is, oxygen consumption (VO2)) and accelerometer counts (that is, vector magnitude (VM)) across a range of speeds during manual wheelchair propulsion on a motor-driven treadmill. Such an association allows for the generation of cutoff points for quantifying the time spent in moderate-to-vigorous physical activity (MVPA) during manual wheelchair propulsion. The study was conducted in the University Laboratory. Twenty-four manual wheelchair users completed a 6-min period of seated rest and three 6-min periods of manual wheelchair propulsion on a motor-driven wheelchair treadmill. The 6-min periods of wheelchair propulsion corresponded with three treadmill speeds (1.5, 3.0 and 4.5 mph) that elicited a range of physical activity intensities. Participants wore a portable metabolic unit and accelerometers on both wrists. Primary outcome measures included steady-state VO2 and VM, and the strength of association between VO2 and VM was based on the multiple correlation and squared multiple correlation coefficients from linear regression analyses. Strong linear associations were established between VO2 and VM for the left (R=0.93±0.44; R2=0.87±0.19), right (R=0.95±0.37; R2=0.90±0.14) and combined (R=0.94±0.38; R2=0.88±0.15) accelerometers. The linear relationship between VO2 and VM for the left, right and combined wrists yielded cutoff points for MVPA of 3659 ±1302, 3630±1403 and 3644±1339 counts min(-1), respectively. We provide cutoff points based on the linear association between energy expenditure and accelerometer counts for estimating time spent in MVPA during manual wheelchair propulsion using wrist-worn accelerometry. The similarity across wrist location permits flexibility in selecting a location for wrist accelerometry placement.

  3. Too hot to move? Objectively assessed seasonal changes in Australian children's physical activity.

    PubMed

    Ridgers, Nicola D; Salmon, Jo; Timperio, Anna

    2015-06-19

    Seasonal variations may influence children's physical activity patterns. The aim of this study was to examine how children's objectively-measured physical activity differed across seasons, and whether different seasonal patterns were observed for boys and girls. Three hundred and twenty-six children aged 8-11 years from nine primary schools in Melbourne, Australia, participated in the study. Physical activity was measured every 15-s using hip-mounted GT3X+ ActiGraph accelerometers for seven consecutive days in the Winter (n = 249), Spring (n = 221), Summer (n = 174) and Autumn (n = 152) school terms. Time spent in moderate (MPA), vigorous (VPA) and moderate- to vigorous-intensity physical activity (MVPA) at each time point was derived using age-specific cut-points. Meteorological data (maximum temperature, precipitation, daylight hours) were obtained daily during each season. Longitudinal data were analysed using multilevel analyses, adjusted for age, sex, accelerometer wear time, number of valid days, and meteorological variables. Compared to Winter, children engaged in significantly less MPA (-5.0 min) and MVPA (-7.8 min) in Summer. Girls engaged in less MVPA in Spring (-18 min) and Summer (-9.2 min) and more MVPA in Autumn (9.9 min) compared to Winter. Significant changes in MPA and VPA bout frequency and duration were also observed. Significant decreases in VPA bout frequency (3.4 bouts) and duration (2.6 min) were observed for girls in Spring compared to Winter. No significant seasonal changes were observed for boys for all intensities and physical activity accumulation. Physical activity decreased in Summer compared to Winter, contrasting previous research that typically reports that children are most active in summer. Greater fluctuations were observed for girls' activity levels. In addition, girls' activity duration and bouts appeared to be more susceptible to seasonal changes compared to boys. The results suggest that strategies to promote physical activity may be needed in Australia during the hot summer months, particularly for girls.

  4. Assessing Stride Variables and Vertical Stiffness with GPS-Embedded Accelerometers: Preliminary Insights for the Monitoring of Neuromuscular Fatigue on the Field

    PubMed Central

    Buchheit, Martin; Gray, Andrew; Morin, Jean-Benoit

    2015-01-01

    The aim of the present study was to examine the ability of a GPS-imbedded accelerometer to assess stride variables and vertical stiffness (K), which are directly related to neuromuscular fatigue during field-based high-intensity runs. The ability to detect stride imbalances was also examined. A team sport player performed a series of 30-s runs on an instrumented treadmill (6 runs at 10, 17 and 24 km·h-1) with or without his right ankle taped (aimed at creating a stride imbalance), while wearing on his back a commercially-available GPS unit with an embedded 100-Hz tri-axial accelerometer. Contact (CT) and flying (FT) time, and K were computed from both treadmill and accelerometers (Athletic Data Innovations) data. The agreement between treadmill (criterion measure) and accelerometer-derived data was examined. We also compared the ability of the different systems to detect the stride imbalance. Biases were small (CT and K) and moderate (FT). The typical error of the estimate was trivial (CT), small (K) and moderate (FT), with nearly perfect (CT and K) and large (FT) correlations for treadmill vs. accelerometer. The tape induced very large increase in the right - left foot ∆ in CT, FT and K measured by the treadmill. The tape effect on CT and K ∆ measured with the accelerometers were also very large, but of lower magnitude than with the treadmill. The tape effect on accelerometer-derived ∆ FT was unclear. Present data highlight the potential of a GPS-embedded accelerometer to assess CT and K during ground running. Key points GPS-embedded tri-axial accelerometers may be used to assess contact time and vertical stiffness during ground running. These preliminary results open new perspective for the field monitoring of neuromuscular fatigue and performance in run-based sports PMID:26664264

  5. Convergent validity of six methods to assess physical activity in daily life.

    PubMed

    Macfarlane, Duncan J; Lee, Cherry C Y; Ho, Edmond Y K; Chan, K L; Chan, Dionise

    2006-11-01

    The purpose was to examine the agreement (convergent validity) between six common measures of habitual physical activity to estimate durations of light, moderate, vigorous, and total activity in a range of free-living individuals. Over 7 consecutive days, 49 ethnic Chinese (30 men, 19 women), aged 15-55 yr, wore a Polar heart rate monitor, a uniaxial MTI, and triaxial Tritrac accelerometer, plus a Yamax pedometer for > or = 600 min/day. They also completed a daily physical activity log and on day 8 a Chinese version of the 7-day International Physical Activity Questionnaire. At each level of activity, there was good agreement between the two questionnaire-derived instruments and the two accelerometry-derived instruments, but wide variation across different instruments, with two- to fourfold differences in mean durations often seen. The heart rate monitor overestimated light activity and underestimated moderate activity compared with all other measures. Spearman correlation coefficients were low to moderate (0.2-0.5) across most measures of activity, with the pedometer showing correlations with total activity that were often superior to the other movement sensors. We conclude that, with the use of commonly accepted cut points for defining light, moderate, vigorous, and total activity, little convergent validity across the instruments was evident, suggesting these measures are sampling different levels of habitual physical activity and care is needed when comparing their results. To provide a more stable comparison of activity among different people, across studies, or against accepted physical activity promotion guidelines, further work is needed to fine tune the different cut points across a range of common activity monitors to provide more consistent results during free-living conditions.

  6. Effects on Vibration and Surface Roughness in High Speed Micro End-Milling of Inconel 718 with Minimum Quantity Lubrication

    NASA Astrophysics Data System (ADS)

    Rahman, Mohamed Abd; Yeakub Ali, Mohammad; Saddam Khairuddin, Amir

    2017-03-01

    This paper presents the study on vibration and surface roughness of Inconel 718 workpiece produced by micro end-milling using Mikrotools Integrated Multi-Process machine tool DT-110 with control parameters; spindle speed (15000 rpm and 30000 rpm), feed rate (2 mm/min and 4 mm/min) and depth of cut (0.10 mm and 0.15mm). The vibration was measured using DYTRAN accelerometer instrument and the average surface roughness Ra was measured using Wyko NT1100. The analysis of variance (ANOVA) by using Design Expert software revealed that feed rate and depth of cut are the most significant factors on vibration meanwhile for average surface roughness, Ra, spindle speed is the most significant factor.

  7. Accelerometer method and apparatus for integral display and control functions

    NASA Astrophysics Data System (ADS)

    Bozeman, Richard J., Jr.

    1992-06-01

    Vibration analysis has been used for years to provide a determination of the proper functioning of different types of machinery, including rotating machinery and rocket engines. A determination of a malfunction, if detected at a relatively early stage in its development, will allow changes in operating mode or a sequenced shutdown of the machinery prior to a total failure. Such preventative measures result in less extensive and/or less expensive repairs, and can also prevent a sometimes catastrophic failure of equipment. Standard vibration analyzers are generally rather complex, expensive, and of limited portability. They also usually result in displays and controls being located remotely from the machinery being monitored. Consequently, a need exists for improvements in accelerometer electronic display and control functions which are more suitable for operation directly on machines and which are not so expensive and complex. The invention includes methods and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. The apparatus includes an accelerometer package having integral display and control functions. The accelerometer package is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine condition over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase over the selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated. The benefits of a vibration recording and monitoring system with controls and displays readily mountable on the machinery being monitored and having capabilities described will be appreciated by those working in the art.

  8. Accelerometer method and apparatus for integral display and control functions

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1992-01-01

    Vibration analysis has been used for years to provide a determination of the proper functioning of different types of machinery, including rotating machinery and rocket engines. A determination of a malfunction, if detected at a relatively early stage in its development, will allow changes in operating mode or a sequenced shutdown of the machinery prior to a total failure. Such preventative measures result in less extensive and/or less expensive repairs, and can also prevent a sometimes catastrophic failure of equipment. Standard vibration analyzers are generally rather complex, expensive, and of limited portability. They also usually result in displays and controls being located remotely from the machinery being monitored. Consequently, a need exists for improvements in accelerometer electronic display and control functions which are more suitable for operation directly on machines and which are not so expensive and complex. The invention includes methods and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. The apparatus includes an accelerometer package having integral display and control functions. The accelerometer package is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine condition over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase over the selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated. The benefits of a vibration recording and monitoring system with controls and displays readily mountable on the machinery being monitored and having capabilities described will be appreciated by those working in the art.

  9. Acceleration environment of payloads while being handled by the Shuttle Remote Manipulator System

    NASA Technical Reports Server (NTRS)

    Turnbull, J. F.

    1983-01-01

    Described in this paper is the method used in the Draper Remote Manipulator System (RMS) Simulation to compute linear accelerations at the point on the SPAS01 payload where its accelerometers are mounted. Simulated accelerometer output for representative on-orbit activities is presented. The objectives of post-flight analysis of SPAS01 data are discussed. Finally, the point is made that designers of acceleration-dependent payloads may have an interest in the capability of simulating the acceleration environment of payloads while under the control of the overall Payload Deployment and retrieval System (PDRS) that includes the Orbiter and its attitude control system as well as the Remote Manipulator Arm.

  10. Cyclostationarity approach for monitoring chatter and tool wear in high speed milling

    NASA Astrophysics Data System (ADS)

    Lamraoui, M.; Thomas, M.; El Badaoui, M.

    2014-02-01

    Detection of chatter and tool wear is crucial in the machining process and their monitoring is a key issue, for: (1) insuring better surface quality, (2) increasing productivity and (3) protecting both machines and safe workpiece. This paper presents an investigation of chatter and tool wear using the cyclostationary method to process the vibrations signals acquired from high speed milling. Experimental cutting tests were achieved on slot milling operation of aluminum alloy. The experimental set-up is designed for acquisition of accelerometer signals and encoding information picked up from an encoder. The encoder signal is used for re-sampling accelerometers signals in angular domain using a specific algorithm that was developed in LASPI laboratory. The use of cyclostationary on accelerometer signals has been applied for monitoring chatter and tool wear in high speed milling. The cyclostationarity appears on average properties (first order) of signals, on the energetic properties (second order) and it generates spectral lines at cyclic frequencies in spectral correlation. Angular power and kurtosis are used to analyze chatter phenomena. The formation of chatter is characterized by unstable, chaotic motion of the tool and strong anomalous fluctuations of cutting forces. Results show that stable machining generates only very few cyclostationary components of second order while chatter is strongly correlated to cyclostationary components of second order. By machining in the unstable region, chatter results in flat angular kurtosis and flat angular power, such as a pseudo (white) random signal with flat spectrum. Results reveal that spectral correlation and Wigner Ville spectrum or integrated Wigner Ville issued from second-order cyclostationary are an efficient parameter for the early diagnosis of faults in high speed machining, such as chatter, tool wear and bearings, compared to traditional stationary methods. Wigner Ville representation of the residual signal shows that the energy corresponding to the tooth passing decreases when chatter phenomenon occurs. The effect of the tool wear and the number of broken teeth on the excitation of structure resonances appears in Wigner Ville presentation.

  11. Sedentary Behaviour Profiling of Office Workers: A Sensitivity Analysis of Sedentary Cut-Points

    PubMed Central

    Boerema, Simone T.; Essink, Gerard B.; Tönis, Thijs M.; van Velsen, Lex; Hermens, Hermie J.

    2015-01-01

    Measuring sedentary behaviour and physical activity with wearable sensors provides detailed information on activity patterns and can serve health interventions. At the basis of activity analysis stands the ability to distinguish sedentary from active time. As there is no consensus regarding the optimal cut-point for classifying sedentary behaviour, we studied the consequences of using different cut-points for this type of analysis. We conducted a battery of sitting and walking activities with 14 office workers, wearing the Promove 3D activity sensor to determine the optimal cut-point (in counts per minute (m·s−2)) for classifying sedentary behaviour. Then, 27 office workers wore the sensor for five days. We evaluated the sensitivity of five sedentary pattern measures for various sedentary cut-points and found an optimal cut-point for sedentary behaviour of 1660 × 10−3 m·s−2. Total sedentary time was not sensitive to cut-point changes within ±10% of this optimal cut-point; other sedentary pattern measures were not sensitive to changes within the ±20% interval. The results from studies analyzing sedentary patterns, using different cut-points, can be compared within these boundaries. Furthermore, commercial, hip-worn activity trackers can implement feedback and interventions on sedentary behaviour patterns, using these cut-points. PMID:26712758

  12. Development of low cost custom hybrid microcircuit technology

    NASA Technical Reports Server (NTRS)

    Perkins, K. L.; Licari, J. J.

    1981-01-01

    Selected potentially low cost, alternate packaging and interconnection techniques were developed and implemented in the manufacture of specific NASA/MSFC hardware, and the actual cost savings achieved by their use. The hardware chosen as the test bed for this evaluation ws the hybrids and modules manufactured by Rockwell International fo the MSFC Flight Accelerometer Safety Cut-Off System (FASCOS). Three potentially low cost packaging and interconnection alternates were selected for evaluation. This study was performed in three phases: hardware fabrication and testing, cost comparison, and reliability evaluation.

  13. Validity of a brief self-report instrument for assessing compliance with physical activity guidelines amongst adolescents.

    PubMed

    Ridgers, Nicola D; Timperio, Anna; Crawford, David; Salmon, Jo

    2012-03-01

    To examine the validity of a brief self-report questionnaire for assessing physical activity, and compliance and non-compliance with moderate-to-vigorous physical activity (MVPA) recommendations in Australian adolescents against accelerometry. Cross-sectional study. MVPA of 203 adolescents (124 females, 79 males) aged 15-17 years was objectively assessed for 8 consecutive days using uni-axial accelerometers and calculated using age-specific cut-points. Adolescents self-reported the number of days (0-7) they were physically active for a total of at least 60 min/day (1) over the past 7 days and (2) over a typical week. Compliance with physical activity recommendations was defined as (1) 5 and (2) 7 days of self-reported MVPA (of at least 60 min/day), and (3) ≥60 min MVPA per average day, and (4) >60 min MVPA on every day according to accelerometry. Spearman's Rho correlations analysed the association between accelerometry-derived MVPA/day and self-reported MVPA days/week for the whole sample, sex and weight status. Percent agreement determined the proportion of adolescents correctly identified as not meeting physical activity recommendations (specificity) or as meeting physical activity recommendations (sensitivity) according to the self-report questionnaire. Moderate to large correlations were found between the self-report and accelerometer data (0.2-0.51) across population subgroups. The percent agreement between the self-report and accelerometry data was good for specificity; however, the sensitivity was low, potentially due to poor compliance with recommendations. Compared to accelerometry, the brief MVPA self-report questionnaire appears to have acceptable validity for measuring non-compliance with physical activity recommendations in 15-17 year old adolescents. Copyright © 2011 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  14. The association between the activity profile and cardiovascular risk.

    PubMed

    Maddison, Ralph; Jiang, Yannan; Foley, Louise; Scragg, Robert; Direito, Artur; Olds, Timothy

    2016-08-01

    This study sought to better understand the interrelationships between physical activity and sedentary behaviour and the relationship to risk of cardiovascular disease (CVDR) in adults aged 30-75 years. Cross-sectional. Data from two-year waves (2003-2004 and 2005-2006) of the National Health and Nutritional Examination survey were analysed in 2014. Accelerometer-derived time and proportion of time spent sedentary and on moderate-to-vigorous physical activity (MVPA) were calculated to generate four activity profiles based on cut-points to define low and high levels for the respective behaviours. Using health outcome data, CVDR was calculated for each person. Weighted multiple linear regression models were used to evaluate the predicted effects of sedentary and physical activity behaviours on the CVDR score, adjusting for participants' sex, age group, race, annual household income, and accelerometer wear time. The lowest CVDR was observed among Busy Exercisers (high MVPA and low sedentary; 8.5%), whereas Couch Potatoes (low MVPA and high sedentary) had the highest (18.6%). Compared with the reference group (Busy Exercisers), the activity profile associated with the highest CVDR was Couch Potatoes (adjusted mean difference 3.6, SE 0.38, p<0.0001). A smoothed three-dimensional response surface "risk landscape" was developed to better visualise the conjoint associations of MVPA and sedentary behaviour on CVDR for each activity profile. The association between MVPA was greater than that of sedentary behaviour; however, for people with low MVPA, shifts in sedentary behaviour may have the greatest impact on CVDR. Activity profiles that consider the interrelationships between physical activity and sedentary behaviour differ in terms of CVDR. Future interventions may need to be tailored to specific profiles and be dynamic enough to reflect change in the profile over time. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  15. [Optimal cut-point of salivary cotinine concentration to discriminate smoking status in the adult population in Barcelona].

    PubMed

    Martínez-Sánchez, Jose M; Fu, Marcela; Ariza, Carles; López, María J; Saltó, Esteve; Pascual, José A; Schiaffino, Anna; Borràs, Josep M; Peris, Mercè; Agudo, Antonio; Nebot, Manel; Fernández, Esteve

    2009-01-01

    To assess the optimal cut-point for salivary cotinine concentration to identify smoking status in the adult population of Barcelona. We performed a cross-sectional study of a representative sample (n=1,117) of the adult population (>16 years) in Barcelona (2004-2005). This study gathered information on active and passive smoking by means of a questionnaire and a saliva sample for cotinine determination. We analyzed sensitivity and specificity according to sex, age, smoking status (daily and occasional), and exposure to second-hand smoke at home. ROC curves and the area under the curve were calculated. The prevalence of smokers (daily and occasional) was 27.8% (95% CI: 25.2-30.4%). The optimal cut-point to discriminate smoking status was 9.2 ng/ml (sensitivity=88.7% and specificity=89.0%). The area under the ROC curve was 0.952. The optimal cut-point was 12.2 ng/ml in men and 7.6 ng/ml in women. The optimal cut-point was higher at ages with a greater prevalence of smoking. Daily smokers had a higher cut-point than occasional smokers. The optimal cut-point to discriminate smoking status in the adult population is 9.2 ng/ml, with sensitivities and specificities around 90%. The cut-point was higher in men and in younger people. The cut-point increases with higher prevalence of daily smokers.

  16. Eutectic-based wafer-level-packaging technique for piezoresistive MEMS accelerometers and bond characterization using molecular dynamics simulations

    NASA Astrophysics Data System (ADS)

    Aono, T.; Kazama, A.; Okada, R.; Iwasaki, T.; Isono, Y.

    2018-03-01

    We developed a eutectic-based wafer-level-packaging (WLP) technique for piezoresistive micro-electromechanical systems (MEMS) accelerometers on the basis of molecular dynamics analyses and shear tests of WLP accelerometers. The bonding conditions were experimentally and analytically determined to realize a high shear strength without solder material atoms diffusing to adhesion layers. Molecular dynamics (MD) simulations and energy dispersive x-ray (EDX) spectrometry done after the shear tests clarified the eutectic reaction of the solder materials used in this research. Energy relaxation calculations in MD showed that the diffusion of solder material atoms into the adhesive layer was promoted at a higher temperature. Tensile creep MD simulations also suggested that the local potential energy in a solder material model determined the fracture points of the model. These numerical results were supported by the shear tests and EDX analyses for WLP accelerometers. Consequently, a bonding load of 9.8 kN and temperature of 300 °C were found to be rational conditions because the shear strength was sufficient to endure the polishing process after the WLP process and there was little diffusion of solder material atoms to the adhesion layer. Also, eutectic-bonding-based WLP was effective for controlling the attenuation of the accelerometers by determining the thickness of electroplated solder materials that played the role of a cavity between the accelerometers and lids. If the gap distance between the two was less than 6.2 µm, the signal gains for x- and z-axis acceleration were less than 20 dB even at the resonance frequency due to air-damping.

  17. Cross-validation of pedometer-determined cut-points for healthy weight in British children from White and South Asian backgrounds.

    PubMed

    Duncan, Michael J; Eyre, Emma L J; Bryant, Elizabeth; Birch, Samantha L

    2014-01-01

    Evidence-based pedometer cut-points for health have not been sufficiently examined in the context of ethnicity. To (1) evaluate previously described steps/day cut-points in a sample of White and South Asian British primary school children and (2) use ROC analysis to generate alternative, ethnic specific, steps/day cut-offs for children. Height, body mass and pedometer determined physical activity were assessed in 763 British children (357 boys and 406 girls) from White (n = 593) and South Asian (n = 170) ethnic groups, aged 8-11 years. The Vincent and Pangrazi cut-points significantly predicted BMI in white (p = 0.006, Adjusted R(2 )= 0.08) and South Asian children (p = 0.039, Adjusted R(2 )= 0.078). The Tudor-Locke et al. cut-points significantly predicted BMI in White children (p = 0.0001, Adjusted R(2 )= 0.079) but not South Asian children (p < 0.05). ROC analysis indicated significant alternative cut-points in White and South Asian boys and girls (all p = 0.04 or better, Adjusted R(2 )= 0.091 for White and 0.09 for South Asian children). Subsequent cut-points associated with healthy weight, when translated to steps/day were 13,625 for White boys, 13,135 for White girls, 10,897 for South Asian boys and 10,161 for South Asian girls. Previously published steps/day cut-points for healthy weight may not account for known ethnic variation in physical activity between White and South Asian children in the UK. Alternative, ethnic-specific, cut-points may be better placed to distinguish British children based on pedometer-determined physical activity.

  18. Tracking Positions and Attitudes of Mars Rovers

    NASA Technical Reports Server (NTRS)

    Ali, Khaled; vanelli, Charles; Biesiadecki, Jeffrey; Martin, Alejandro San; Maimone, Mark; Cheng, Yang; Alexander, James

    2006-01-01

    The Surface Attitude Position and Pointing (SAPP) software, which runs on computers aboard the Mars Exploration Rovers, tracks the positions and attitudes of the rovers on the surface of Mars. Each rover acquires data on attitude from a combination of accelerometer readings and images of the Sun acquired autonomously, using a pointable camera to search the sky for the Sun. Depending on the nature of movement commanded remotely by operators on Earth, the software propagates attitude and position by use of either (1) accelerometer and gyroscope readings or (2) gyroscope readings and wheel odometry. Where necessary, visual odometry is performed on images to fine-tune the position updates, particularly on high-wheel-slip terrain. The attitude data are used by other software and ground-based personnel for pointing a high-gain antenna, planning and execution of driving, and positioning and aiming scientific instruments.

  19. Magnetic field `flyby' measurement using a smartphone's magnetometer and accelerometer simultaneously

    NASA Astrophysics Data System (ADS)

    Monteiro, Martín; Stari, Cecilia; Cabeza, Cecilia; Marti, Arturo C.

    2017-12-01

    The spatial dependence of magnetic fields in simple configurations is a common topic in introductory electromagnetism lessons, both in high school and in university courses. In typical experiments, magnetic fields and distances are obtained taking point-by-point values using a Hall sensor and a ruler, respectively. Here, we show how to take advantage of the smartphone capabilities to get simultaneous measures with the built-in accelerometer and magnetometer and to obtain the spatial dependence of magnetic fields. We consider a simple setup consisting of a smartphone mounted on a track whose direction coincides with the axis of a coil. While the smartphone is moving on the track, both the magnetic field and the distance from the center of the coil (integrated numerically from the acceleration values) are simultaneously obtained. This methodology can easily be extended to more complicated setups.

  20. Atmospheric Modeling Using Accelerometer Data During Mars Atmosphere and Volatile Evolution (MAVEN) Flight Operations

    NASA Technical Reports Server (NTRS)

    Tolson, Robert H.; Lugo, Rafael A.; Baird, Darren T.; Cianciolo, Alicia D.; Bougher, Stephen W.; Zurek, Richard M.

    2017-01-01

    The Mars Atmosphere and Volatile EvolutioN (MAVEN) spacecraft is a NASA orbiter designed to explore the Mars upper atmosphere, typically from 140 to 160 km altitude. In addition to the nominal science mission, MAVEN has performed several Deep Dip campaigns in which the orbit's closest point of approach, also called periapsis, was lowered to an altitude range of 115 to 135 km. MAVEN accelerometer data were used during mission operations to estimate atmospheric parameters such as density, scale height, along-track gradients, and wave structures. Density and scale height estimates were compared against those obtained from the Mars Global Reference Atmospheric Model and used to aid the MAVEN navigation team in planning maneuvers to raise and lower periapsis during Deep Dip operations. This paper describes the processes used to reconstruct atmosphere parameters from accelerometers data and presents the results of their comparison to model and navigation-derived values.

  1. Validity and reliability of the Physical Activity Questionnaire for Children (PAQ-C) and Adolescents (PAQ-A) in individuals with congenital heart disease.

    PubMed

    Voss, Christine; Dean, Paige H; Gardner, Ross F; Duncombe, Stephanie L; Harris, Kevin C

    2017-01-01

    To assess the criterion validity, internal consistency, reliability and cut-point for the Physical Activity Questionnaire for Children (PAQ-C) and Adolescents (PAQ-A) in children and adolescents with congenital heart disease-a special population at high cardiovascular risk in whom physical activity has not been extensively evaluated. We included 84 participants (13.6±2.9 yrs, 50% female) with simple (37%), moderate (31%), or severe congenital heart disease (27%), as well as cardiac transplant recipients (6%), from BC Children's Hospital, Canada. They completed the PAQ-C (≤11yrs, n = 28) or-A (≥12yrs, n = 56), and also wore a triaxial accelerometer (GT3X+ or GT9X) over the right hip for 7 days (n = 59 met valid wear time criteria). Median daily moderate-to-vigorous physical activity was 46.9 minutes per day (IQR 31.6-61.8) and 25% met physical activity guidelines defined as ≥60 minutes of moderate-to-vigorous physical activity per day. Median PAQ-score was 2.6 (IQR 1.9-3.0). PAQ-Scores were significantly related to accelerometry-derived metrics of physical activity (rho = 0.44-0.55, all p<0.01) and sedentary behaviour (rho = -0.53, p<0.001). Internal consistency was high (α = 0.837), as was reliability (stability) of PAQ-Scores over a 4-months period (ICC = 0.73, 95%CI 0.55-0.84; p<0.001). We identified that a PAQ-Score cut-point of 2.87 discriminates between those meeting physical guidelines and those that do not in the combined PAQ-C and-A samples (area under the curve = 0.80 (95%CI 0.67-0.92). Validity and reliability of the PAQ in children and adolescents with CHD was comparable to or stronger than previous studies in healthy children. Therefore, the PAQ may be used to estimate general levels of physical activity in children and adolescents with CHD.

  2. Inertial navigation without accelerometers

    NASA Astrophysics Data System (ADS)

    Boehm, M.

    The Kennedy-Thorndike (1932) experiment points to the feasibility of fiber-optic inertial velocimeters, to which state-of-the-art technology could furnish substantial sensitivity and accuracy improvements. Velocimeters of this type would obviate the use of both gyros and accelerometers, and allow inertial navigation to be conducted together with vehicle attitude control, through the derivation of rotation rates from the ratios of the three possible velocimeter pairs. An inertial navigator and reference system based on this approach would probably have both fewer components and simpler algorithms, due to the obviation of the first level of integration in classic inertial navigators.

  3. Maximum Acceleration Recording Circuit

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1995-01-01

    Coarsely digitized maximum levels recorded in blown fuses. Circuit feeds power to accelerometer and makes nonvolatile record of maximum level to which output of accelerometer rises during measurement interval. In comparison with inertia-type single-preset-trip-point mechanical maximum-acceleration-recording devices, circuit weighs less, occupies less space, and records accelerations within narrower bands of uncertainty. In comparison with prior electronic data-acquisition systems designed for same purpose, circuit simpler, less bulky, consumes less power, costs and analysis of data recorded in magnetic or electronic memory devices. Circuit used, for example, to record accelerations to which commodities subjected during transportation on trucks.

  4. Nonlinear dynamics under varying temperature conditions of the resonating beams of a differential resonant accelerometer

    NASA Astrophysics Data System (ADS)

    Zhang, Jing; Wang, Yagang; Zega, Valentina; Su, Yan; Corigliano, Alberto

    2018-07-01

    In this work the nonlinear dynamic behaviour under varying temperature conditions of the resonating beams of a differential resonant accelerometer is studied from the theoretical, numerical and experimental points of view. A complete analytical model based on the Hamilton’s principle is proposed to describe the nonlinear behaviour of the resonators under varying temperature conditions and numerical solutions are presented in comparison with experimental data. This provides a novel perspective to examine the relationship between temperature and nonlinearity, which helps predicting the dynamic behaviour of resonant devices and can guide their optimal design.

  5. Noise-Immune Multisensor Transduction of Speech.

    DTIC Science & Technology

    1986-08-01

    for each of the six attributes: voicing, nasality, sustention , sibilation, graveness, and compactness [5]. Each of the rhyming pairs associated with the...Nasality involves discrimination between nasal and non-nasal sounds (e.g., meat vs. beat); sustention involves discrimination between stop sounds and non...the addition of the accelerometer to M12 improved voicing by 13.2 points, sustention by 19.5 points, and graveness by 14.1 points. Comparing (ACC, M12

  6. Magnetic Field "Flyby" Measurement Using a Smartphone's Magnetometer and Accelerometer Simultaneously

    ERIC Educational Resources Information Center

    Monteiro, Martin; Stari, Cecilia; Cabeza, Cecilia; Marti, Arturo C.

    2017-01-01

    The spatial dependence of magnetic fields in simple configurations is a common topic in introductory electromagnetism lessons, both in high school and in university courses. In typical experiments, magnetic fields and distances are obtained taking point-by-point values using a Hall sensor and a ruler, respectively. Here, we show how to take…

  7. Interethnic differences in the accuracy of anthropometric indicators of obesity in screening for high risk of coronary heart disease

    PubMed Central

    Herrera, VM; Casas, JP; Miranda, JJ; Perel, P; Pichardo, R; González, A; Sanchez, JR; Ferreccio, C; Aguilera, X; Silva, E; Oróstegui, M; Gómez, LF; Chirinos, JA; Medina-Lezama, J; Pérez, CM; Suárez, E; Ortiz, AP; Rosero, L; Schapochnik, N; Ortiz, Z; Ferrante, D; Diaz, M; Bautista, LE

    2009-01-01

    Background Cut points for defining obesity have been derived from mortality data among Whites from Europe and the United States and their accuracy to screen for high risk of coronary heart disease (CHD) in other ethnic groups has been questioned. Objective To compare the accuracy and to define ethnic and gender-specific optimal cut points for body mass index (BMI), waist circumference (WC) and waist-to-hip ratio (WHR) when they are used in screening for high risk of CHD in the Latin-American and the US populations. Methods We estimated the accuracy and optimal cut points for BMI, WC and WHR to screen for CHD risk in Latin Americans (n=18 976), non-Hispanic Whites (Whites; n=8956), non-Hispanic Blacks (Blacks; n=5205) and Hispanics (n=5803). High risk of CHD was defined as a 10-year risk ≥20% (Framingham equation). The area under the receiver operator characteristic curve (AUC) and the misclassification-cost term were used to assess accuracy and to identify optimal cut points. Results WHR had the highest AUC in all ethnic groups (from 0.75 to 0.82) and BMI had the lowest (from 0.50 to 0.59). Optimal cut point for BMI was similar across ethnic/gender groups (27 kg/m2). In women, cut points for WC (94 cm) and WHR (0.91) were consistent by ethnicity. In men, cut points for WC and WHR varied significantly with ethnicity: from 91 cm in Latin Americans to 102 cm in Whites, and from 0.94 in Latin Americans to 0.99 in Hispanics, respectively. Conclusion WHR is the most accurate anthropometric indicator to screen for high risk of CHD, whereas BMI is almost uninformative. The same BMI cut point should be used in all men and women. Unique cut points for WC and WHR should be used in all women, but ethnic-specific cut points seem warranted among men. PMID:19238159

  8. An Investigation of Energy Transmission Due to Flexural Wave Propagation in Lightweight, Built-Up Structures. Thesis

    NASA Technical Reports Server (NTRS)

    Mickol, John Douglas; Bernhard, R. J.

    1986-01-01

    A technique to measure flexural structure-borne noise intensity is investigated. Two accelerometers serve as transducers in this cross-spectral technique. The structure-borne sound power is obtained by two different techniques and compared. In the first method, a contour integral of intensity is performed from the values provided by the two-accelerometer intensity technique. In the second method, input power is calculated directly from the output of force and acceleration transducers. A plate and two beams were the subjects of the sound power comparisons. Excitation for the structures was either band-limited white noise or a deterministic signal similar to a swept sine. The two-accelerometer method was found to be sharply limited by near field and transducer spacing limitations. In addition, for the lightweight structures investigated, it was found that the probe inertia can have a significant influence on the power input to the structure. In addition to the experimental investigation of structure-borne sound energy, an extensive study of the point harmonically forced, point-damped beam boundary value problem was performed to gain insight into measurements of this nature. The intensity formulations were also incorporated into the finite element method. Intensity mappings were obtained analytically via finite element modeling of simple structures.

  9. Silicon micromachined accelerometer/seismometer and method of making the same

    NASA Technical Reports Server (NTRS)

    Martin, Richard D. (Inventor); Pike, W. Thomas (Inventor)

    2001-01-01

    A silicon-based microaccelerometer for seismic application is provided using a low-resonant frequency (10 Hz), large proof mass (1 gram), and high Q suspension to achieve high sensitivity of less than 1 ng with a bandwidth a 0.05 to 50 Hz. The proof mass is cut away from a planar substrate in the form of a disk using abrasive cutting, which disk closely fits but does not touch a surrounding angular frame. The spring of the microaccelerometer between the angular frame and the proof mass is provided from two continuous, 3 microns thick membranes. The fixed capacitive electrodes are provided on separate, subsequently bonded substrates, and movable capacitive plates are provided on the membranes. By fabricating capacitive plates on the separate substrates, the gap between the fixed and movable capacitive plates in the differential capacitive sensor is closely controlled. The use of continuous membranes for the spring produces a shock resistant, robust sensor.

  10. Evaluation of a novel canine activity monitor for at-home physical activity analysis.

    PubMed

    Yashari, Jonathan M; Duncan, Colleen G; Duerr, Felix M

    2015-07-04

    Accelerometers are motion-sensing devices that have been used to assess physical activity in dogs. However, the lack of a user-friendly, inexpensive accelerometer has hindered the widespread use of this objective outcome measure in veterinary research. Recently, a smartphone-based, affordable activity monitor (Whistle) has become available for measurement of at-home physical activity in dogs. The aim of this research was to evaluate this novel accelerometer. Eleven large breed, privately owned dogs wore a collar fitted with both the Whistle device and a previously validated accelerometer-based activity monitor (Actical) for a 24-h time period. Owners were asked to have their dogs resume normal daily activities. Total activity time obtained from the Whistle device in minutes was compared to the total activity count from the Actical device. Activity intensity from the Whistle device was calculated manually from screenshots of the activity bars displayed in the smartphone-application and compared to the activity count recorded by the Actical in the same 3-min time period. A total of 3740 time points were compared. There was a strong correlation between activity intensity of both devices for individual time points (Pearson's correlation coefficient 0.81, p < 0.0001). An even stronger correlation was observed between the total activity data between the two devices (Pearson's correlation coefficient 0.925, p < 0.0001). Activity data provided by the Whistle activity monitor may be used as an objective outcome measurement in dogs. The total activity time provided by the Whistle application offers an inexpensive method for obtaining at-home, canine, real-time physical activity data. Limitations of the Whistle device include the limited battery life, the need for manual derivation of activity intensity data and data transfer, and the requirement of Wi-Fi and Bluetooth availability for data transmission.

  11. Maxwell Strata and Cut Locus in the Sub-Riemannian Problem on the Engel Group

    NASA Astrophysics Data System (ADS)

    Ardentov, Andrei A.; Sachkov, Yuri L.

    2017-12-01

    We consider the nilpotent left-invariant sub-Riemannian structure on the Engel group. This structure gives a fundamental local approximation of a generic rank 2 sub-Riemannian structure on a 4-manifold near a generic point (in particular, of the kinematic models of a car with a trailer). On the other hand, this is the simplest sub-Riemannian structure of step three. We describe the global structure of the cut locus (the set of points where geodesics lose their global optimality), the Maxwell set (the set of points that admit more than one minimizer), and the intersection of the cut locus with the caustic (the set of conjugate points along all geodesics). The group of symmetries of the cut locus is described: it is generated by a one-parameter group of dilations R+ and a discrete group of reflections Z2 × Z2 × Z2. The cut locus admits a stratification with 6 three-dimensional strata, 12 two-dimensional strata, and 2 one-dimensional strata. Three-dimensional strata of the cut locus are Maxwell strata of multiplicity 2 (for each point there are 2 minimizers). Two-dimensional strata of the cut locus consist of conjugate points. Finally, one-dimensional strata are Maxwell strata of infinite multiplicity, they consist of conjugate points as well. Projections of sub-Riemannian geodesics to the 2-dimensional plane of the distribution are Euler elasticae. For each point of the cut locus, we describe the Euler elasticae corresponding to minimizers coming to this point. Finally, we describe the structure of the optimal synthesis, i. e., the set of minimizers for each terminal point in the Engel group.

  12. Microgravity Science Laboratory (MSL-1)

    NASA Technical Reports Server (NTRS)

    Robinson, M. B. (Compiler)

    1998-01-01

    The MSL-1 payload first flew on the Space Shuttle Columbia (STS-83) April 4-8, 1997. Due to a fuel cell problem, the mission was cut short, and the payload flew again on Columbia (STS-94) July 1-17, 1997. The MSL-1 investigations were performed in a pressurized Spacelab module and the Shuttle middeck. Twenty-nine experiments were performed and represented disciplines such as fluid physics, combustion, materials science, biotechnology, and plant growth. Four accelerometers were used to record and characterize the microgravity environment. The results demonstrate the range of quality science that can be conducted utilizing orbital laboratories in microgravity.

  13. Validation of the RT3 triaxial accelerometer for the assessment of physical activity.

    PubMed

    Rowlands, Ann V; Thomas, Philip W M; Eston, Roger G; Topping, Rodney

    2004-03-01

    The aims of this study were to assess and compare the validity of the RT3 accelerometer for the assessment of physical activity in boys and men, to compare RT3 and Tritrac accelerometer counts, and to determine count cut-off values for moderate (> or =3 < 6 METs) and vigorous (> or =6 METs) activity. Nineteen boys (age: 9.5 +/- 0.8 yr) and 15 men (age: 20.7 +/- 1.4 yr) walked and ran on a treadmill, kicked a ball to and fro, played hopscotch, and sat quietly. An RT3 was worn on the right hip; boys also wore a Tritrac on the left hip. Oxygen consumption was expressed as a ratio of body mass raised to the power of 0.75 (S VO2). RT3 counts correlated significantly with S VO2 in boys (r = 0.87, P < 0.01) and men (r = 0.85, P < 0.01). However, during treadmill activities, RT3 counts were significantly higher for boys (P < 0.05). RT3 counts corresponding to "moderate" and "vigorous" activity were similar for boys and men for all activities (moderate = 970.2 for boys and 984.0 for men; vigorous = 2333.0 for boys and 2340.8 for men) but approximately 400 counts lower in men when only treadmill activities were considered. Tritrac counts correlated significantly with S VO2 in boys (r = 0.87, P < 0.01), but were significantly lower than RT3 counts across most activities (P < 0.05). The RT3 accelerometer is a good measure of physical activity for boys and men. However, moderate and vigorous intensity count thresholds differ for boys and men when the predominant activities are walking and running. RT3 counts are significantly higher than Tritrac counts for a number of activities. These findings have implications when comparing activity counts between studies using the different instruments.

  14. Determining BMI cut points based on excess percent body fat in US children and adolescents

    USDA-ARS?s Scientific Manuscript database

    Current cut points for overweight were derived statistically from BMI distribution. The study aimed at determining age-, gender-, and ethnic-specific BMI cut points based on excess body fat in US children and adolescents aged 8-17 years, who participated in the National Health and Nutrition Examinat...

  15. Validity and reliability of two brief physical activity questionnaires among Spanish-speaking individuals of Mexican descent.

    PubMed

    Vega-López, Sonia; Chavez, Adrian; Farr, Kristin J; Ainsworth, Barbara E

    2014-01-13

    Mexican Americans are the largest minority group in the US and suffer disproportionate rates of diseases related to the lack of physical activity (PA). Since many of these Mexican Americans are Spanish-speaking, it is important to validate a Spanish language physical activity assessment tool that can be used in epidemiology as well as clinical practice. This study explored the utility of two Spanish translated physical activity questionnaires, the Stanford Brief Activity Survey (SBAS) and the Rapid Assessment of Physical Activity (RAPA), for use among Spanish-speaking Mexican Americans. Thirty-four participants (13 M, 21 F; 37.6 ± 9.5 y) completed each of the two PA surveys twice, one week apart. During that week 31 participants also wore an ActiGraph GT1M accelerometer for 7 days to objectively measure PA. Minutes of moderate and vigorous PA (MVPA) were determined from the accelerometer data using Freedson and Matthews cut points. Validity, determined by Spearman correlation coefficients between questionnaire scores and minutes of ActiGraph measured MVPA were 0.38 and 0.45 for the SBAS and RAPA, respectively. Test-retest reliability was 0.61 for the SBAS and 0.65 for the RAPA. Sensitivity and specificity were 0.60 and 0.47 for the SBAS, and 0.73 and 0.75 for the RAPA. Participants who were classified as meeting the 2008 National Physical Activity Guidelines by the RAPA engaged in significantly (p < 0.05) more minutes of MVPA than those who were not, while there were no significant differences in minutes of MVPA classified by the SBAS. The SBAS and the RAPA are both reasonably valid measures for quickly assessing PA and determining compliance to the PA guidelines in Spanish-speaking Mexican Americans. Although the two questionnaires had comparable reliability, the RAPA was better able to distinguish between those who met and did not meet National PA Guidelines.

  16. Validity and reliability of two brief physical activity questionnaires among Spanish-speaking individuals of Mexican descent

    PubMed Central

    2014-01-01

    Background Mexican Americans are the largest minority group in the US and suffer disproportionate rates of diseases related to the lack of physical activity (PA). Since many of these Mexican Americans are Spanish-speaking, it is important to validate a Spanish language physical activity assessment tool that can be used in epidemiology as well as clinical practice. This study explored the utility of two Spanish translated physical activity questionnaires, the Stanford Brief Activity Survey (SBAS) and the Rapid Assessment of Physical Activity (RAPA), for use among Spanish-speaking Mexican Americans. Methods Thirty-four participants (13 M, 21 F; 37.6 ± 9.5 y) completed each of the two PA surveys twice, one week apart. During that week 31 participants also wore an ActiGraph GT1M accelerometer for 7 days to objectively measure PA. Minutes of moderate and vigorous PA (MVPA) were determined from the accelerometer data using Freedson and Matthews cut points. Results Validity, determined by Spearman correlation coefficients between questionnaire scores and minutes of ActiGraph measured MVPA were 0.38 and 0.45 for the SBAS and RAPA, respectively. Test-retest reliability was 0.61 for the SBAS and 0.65 for the RAPA. Sensitivity and specificity were 0.60 and 0.47 for the SBAS, and 0.73 and 0.75 for the RAPA. Participants who were classified as meeting the 2008 National Physical Activity Guidelines by the RAPA engaged in significantly (p < 0.05) more minutes of MVPA than those who were not, while there were no significant differences in minutes of MVPA classified by the SBAS. Conclusions The SBAS and the RAPA are both reasonably valid measures for quickly assessing PA and determining compliance to the PA guidelines in Spanish-speaking Mexican Americans. Although the two questionnaires had comparable reliability, the RAPA was better able to distinguish between those who met and did not meet National PA Guidelines. PMID:24410978

  17. Body mass index, waist circumference and waist-to-hip ratio cut-off points for categorisation of obesity among Omani Arabs.

    PubMed

    Al-Lawati, Jawad A; Jousilahti, Pekka

    2008-01-01

    There are no data on optimal cut-off points to classify obesity among Omani Arabs. The existing cut-off points were obtained from studies of European populations. To determine gender-specific optimal cut-off points for body mass index (BMI), waist circumference (WC) and waist-to-hip ratio (WHR) associated with elevated prevalent cardiovascular disease (CVD) risk among Omani Arabs. A community-based cross-sectional study. The survey was conducted in the city of Nizwa in Oman in 2001. The study contained a probabilistic random sample of 1421 adults aged > or =20 years. Prevalent CVD risk was defined as the presence of at least two of the following three risk factors: hyperglycaemia, hypertension and dyslipidaemia. Logistic regression and receiver-operating characteristic (ROC) curve analyses were used to determine optimal cut-off points for BMI, WC and WHR in relation to the area under the curve (AUC), sensitivity and specificity. Over 87% of Omanis had at least one CVD risk factor (38% had hyperglycaemia, 19% hypertension and 34.5% had high total cholesterol). All three indices including BMI (AUC = 0.766), WC (AUC = 0.772) and WHR (AUC = 0.767) predicted prevalent CVD risk factors equally well. The optimal cut-off points for men and women respectively were 23.2 and 26.8 kg m-2 for BMI, 80.0 and 84.5 cm for WC, and 0.91 and 0.91 for WHR. To identify Omani subjects of Arab ethnicity at high risk of CVD, cut-off points lower than currently recommended for BMI, WC and WHR are needed for men while higher cut-off points are suggested for women.

  18. Using expired air carbon monoxide to determine smoking status during pregnancy: preliminary identification of an appropriately sensitive and specific cut-point.

    PubMed

    Bailey, Beth A

    2013-10-01

    Measurement of carbon monoxide in expired air samples (ECO) is a non-invasive, cost-effective biochemical marker for smoking. Cut points of 6ppm-10ppm have been established, though appropriate cut-points for pregnant woman have been debated due to metabolic changes. This study assessed whether an ECO cut-point identifying at least 90% of pregnant smokers, and misidentifying fewer than 10% of non-smokers, could be established. Pregnant women (N=167) completed a validated self-report smoking assessment, a urine drug screen for cotinine (UDS), and provided an expired air sample twice during pregnancy. Half of women reported non-smoking status early (51%) and late (53%) in pregnancy, confirmed by UDS. Using a traditional 8ppm+cut-point for the early pregnancy reading, only 1% of non-smokers were incorrectly identified as smokers, but only 56% of all smokers, and 67% who smoked 5+ cigarettes in the previous 24h, were identified. However, at 4ppm+, only 8% of non-smokers were misclassified as smokers, and 90% of all smokers and 96% who smoked 5+ cigarettes in the previous 24h were identified. False positives were explained by heavy second hand smoke exposure and marijuana use. Results were similar for late pregnancy ECO, with ROC analysis revealing an area under the curve of .95 for early pregnancy, and .94 for late pregnancy readings. A lower 4ppm ECO cut-point may be necessary to identify pregnant smokers using expired air samples, and this cut-point appears valid throughout pregnancy. Work is ongoing to validate findings in larger samples, but it appears if an appropriate cut-point is used, ECO is a valid method for determining smoking status in pregnancy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Multivariate meta-analysis of prognostic factor studies with multiple cut-points and/or methods of measurement.

    PubMed

    Riley, Richard D; Elia, Eleni G; Malin, Gemma; Hemming, Karla; Price, Malcolm P

    2015-07-30

    A prognostic factor is any measure that is associated with the risk of future health outcomes in those with existing disease. Often, the prognostic ability of a factor is evaluated in multiple studies. However, meta-analysis is difficult because primary studies often use different methods of measurement and/or different cut-points to dichotomise continuous factors into 'high' and 'low' groups; selective reporting is also common. We illustrate how multivariate random effects meta-analysis models can accommodate multiple prognostic effect estimates from the same study, relating to multiple cut-points and/or methods of measurement. The models account for within-study and between-study correlations, which utilises more information and reduces the impact of unreported cut-points and/or measurement methods in some studies. The applicability of the approach is improved with individual participant data and by assuming a functional relationship between prognostic effect and cut-point to reduce the number of unknown parameters. The models provide important inferential results for each cut-point and method of measurement, including the summary prognostic effect, the between-study variance and a 95% prediction interval for the prognostic effect in new populations. Two applications are presented. The first reveals that, in a multivariate meta-analysis using published results, the Apgar score is prognostic of neonatal mortality but effect sizes are smaller at most cut-points than previously thought. In the second, a multivariate meta-analysis of two methods of measurement provides weak evidence that microvessel density is prognostic of mortality in lung cancer, even when individual participant data are available so that a continuous prognostic trend is examined (rather than cut-points). © 2015 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd.

  20. Operationalizing hippocampal volume as an enrichment biomarker for amnestic MCI trials: effect of algorithm, test-retest variability and cut-point on trial cost, duration and sample size

    PubMed Central

    Yu, P.; Sun, J.; Wolz, R.; Stephenson, D.; Brewer, J.; Fox, N.C.; Cole, P.E.; Jack, C.R.; Hill, D.L.G.; Schwarz, A.J.

    2014-01-01

    Objective To evaluate the effect of computational algorithm, measurement variability and cut-point on hippocampal volume (HCV)-based patient selection for clinical trials in mild cognitive impairment (MCI). Methods We used normal control and amnestic MCI subjects from ADNI-1 as normative reference and screening cohorts. We evaluated the enrichment performance of four widely-used hippocampal segmentation algorithms (FreeSurfer, HMAPS, LEAP and NeuroQuant) in terms of two-year changes in MMSE, ADAS-Cog and CDR-SB. We modeled the effect of algorithm, test-retest variability and cut-point on sample size, screen fail rates and trial cost and duration. Results HCV-based patient selection yielded not only reduced sample sizes (by ~40–60%) but also lower trial costs (by ~30–40%) across a wide range of cut-points. Overall, the dependence on the cut-point value was similar for the three clinical instruments considered. Conclusion These results provide a guide to the choice of HCV cut-point for aMCI clinical trials, allowing an informed trade-off between statistical and practical considerations. PMID:24211008

  1. Prototype Earthquake Early Warning System for Areas of Highest Seismic Risk in the Western U.S.

    NASA Astrophysics Data System (ADS)

    Bock, Y.; Geng, J.; Goldberg, D.; Saunders, J. K.; Haase, J. S.; Squibb, M. B.; Melgar, D.; Crowell, B. W.; Clayton, R. W.; Yu, E.; Walls, C. P.; Mann, D.; Mencin, D.; Mattioli, G. S.

    2015-12-01

    We report on a prototype earthquake early warning system for the Western U.S. based on GNSS (GPS+GLONASS) observations, and where available collocated GNSS and accelerometer data (seismogeodesy). We estimate with latency of 2-3 seconds GNSS displacement waveforms from more than 120 stations, focusing on the southern segment of the San Andreas fault, the Hayward and Rodgers Creek faults and Cascadia. The displacements are estimated using precise point positioning with ambiguity resolution (PPP-AR), which provides for efficient processing of hundreds of "clients" within the region of interest with respect to a reference frame well outside the expected zone of deformation. The GNSS displacements are useful for alleviating magnitude saturation concerns, rapid earthquake magnitude estimation using peak ground displacements, CMT solutions and finite fault slip models. However, GNSS alone is insufficient for strict earthquake early warning (i.e., P wave detection). Therefore, we employ a self-contained seismogeodetic technique, where collocations of GNSS and accelerometer instruments are available, to estimate real-time displacement and velocity waveforms using PPP-AR with accelerometers (PPP-ARA). Using the velocity waveforms we can detect the P wave arrival for earthquakes of interest (>M 5.5), estimate a hypocenter, S wave propagation, and earthquake magnitude using Pd scaling relationships within seconds. Currently we are gearing up to receive observatory-grade accelerometer data from the CISN. We have deployed 25 inexpensive MEMS accelerometers at existing GNSS stations. The SIO Geodetic Modules that control the flow of the GNSS and accelerometer data are being upgraded with in situ PPP-ARA and P wave picking. In situ processing allows us to use the data at the highest sampling rate of the GNSS receiver (10 Hz or higher), in combination with the 100 Hz accelerometer data. Adding the GLONASS data allows for increased precision in the vertical, an important factor in P wave detection, and by reducing outliers, increasing the number of visible satellites and significantly reducing the time required for reinitialization of phase ambiguities. We plan to make our displacement and velocity waveforms available to the USGS ShakeAlert system and others in Earthworm format.

  2. The Use of Microcomputers to Improve Army Ground-Vehicle Readiness

    DTIC Science & Technology

    1980-03-01

    point indicated in Fig. 1. A demonstration of the leverage of the algorithmic parameter transformation can be inferred from data from automobile ...data) 45 data input channels: 1 accelerometer 22 digital data 22 analog data Backup battery Modular software architecture Field reprogrammable

  3. 49 CFR 572.77 - Instrumentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the sensitive axes of the three accelerometers intersect at the point in the midsagittal plane located... pins in either side of the dummy's head with the head's midsagittal plane. (2) The head has three... is perpendicular to the horizontal bulkhead in the midsagittal plane. (ii) Align the second...

  4. Grumman WS33 wind system. Phase II: executive summary. Prototype construction and testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adler, F M; Hinton, P; King, P W

    1980-11-01

    The configuration of an 8 kW wind turbine generator and its fabrication and pre-delivery testing are discussed. The machine is a three-bladed, down wind turbine designed to interface directly with an electrical utility network. Power is generated in winds between a cut-in speed of 4.0 m/s and a cut-out speed of 22 m/s. A blade pitch control system provides for positioning the rotor at a coarse pitch for start-up, fine pitch for normal running, and a feather position for shut-down. Operation of the machine is controlled by a self-monitoring, programmable logic microprocessor. System components were obtained through a series ofmore » make-buy decisions, tracked and inspected for specification compliance. Only minor modifications from the original design and minor problems of assembly are reported. Four accelerometers were mounted inside the nacelle to determine the accelerations, frequencies and displacements of the system in the three orthogonal axes. A cost analysis is updated. (LEW)« less

  5. Dew point measurement technique utilizing fiber cut reflection

    NASA Astrophysics Data System (ADS)

    Kostritskii, S. M.; Dikevich, A. A.; Korkishko, Yu. N.; Fedorov, V. A.

    2009-05-01

    The fiber optical dew point hygrometer based on change of reflection coefficient for fiber cut has been developed and examined. We proposed and verified the model of condensation detector functioning principle. Experimental frost point measurements on air with different frost points have been performed.

  6. Wave Measurements Using GPS Velocity Signals

    PubMed Central

    Doong, Dong-Jiing; Lee, Beng-Chun; Kao, Chia Chuen

    2011-01-01

    This study presents the idea of using GPS-output velocity signals to obtain wave measurement data. The application of the transformation from a velocity spectrum to a displacement spectrum in conjunction with the directional wave spectral theory are the core concepts in this study. Laboratory experiments were conducted to verify the accuracy of the inversed displacement of the surface of the sea. A GPS device was installed on a moored accelerometer buoy to verify the GPS-derived wave parameters. It was determined that loss or drifting of the GPS signal, as well as energy spikes occurring in the low frequency band led to erroneous measurements. Through the application of moving average skill and a process of frequency cut-off to the GPS output velocity, correlations between GPS-derived, and accelerometer buoy-measured significant wave heights and periods were both improved to 0.95. The GPS-derived one-dimensional and directional wave spectra were in agreement with the measurements. Despite the direction verification showing a 10° bias, this exercise still provided useful information with sufficient accuracy for a number of specific purposes. The results presented in this study indicate that using GPS output velocity is a reasonable alternative for the measurement of ocean waves. PMID:22346618

  7. Cutting tool form compensation system and method

    DOEpatents

    Barkman, W.E.; Babelay, E.F. Jr.; Klages, E.J.

    1993-10-19

    A compensation system for a computer-controlled machining apparatus having a controller and including a cutting tool and a workpiece holder which are movable relative to one another along a preprogrammed path during a machining operation utilizes a camera and a vision computer for gathering information at a preselected stage of a machining operation relating to the actual shape and size of the cutting edge of the cutting tool and for altering the preprogrammed path in accordance with detected variations between the actual size and shape of the cutting edge and an assumed size and shape of the cutting edge. The camera obtains an image of the cutting tool against a background so that the cutting tool and background possess contrasting light intensities, and the vision computer utilizes the contrasting light intensities of the image to locate points therein which correspond to points along the actual cutting edge. Following a series of computations involving the determining of a tool center from the points identified along the tool edge, the results of the computations are fed to the controller where the preprogrammed path is altered as aforedescribed. 9 figures.

  8. Cutting tool form compensaton system and method

    DOEpatents

    Barkman, William E.; Babelay, Jr., Edwin F.; Klages, Edward J.

    1993-01-01

    A compensation system for a computer-controlled machining apparatus having a controller and including a cutting tool and a workpiece holder which are movable relative to one another along a preprogrammed path during a machining operation utilizes a camera and a vision computer for gathering information at a preselected stage of a machining operation relating to the actual shape and size of the cutting edge of the cutting tool and for altering the preprogrammed path in accordance with detected variations between the actual size and shape of the cutting edge and an assumed size and shape of the cutting edge. The camera obtains an image of the cutting tool against a background so that the cutting tool and background possess contrasting light intensities, and the vision computer utilizes the contrasting light intensities of the image to locate points therein which correspond to points along the actual cutting edge. Following a series of computations involving the determining of a tool center from the points identified along the tool edge, the results of the computations are fed to the controller where the preprogrammed path is altered as aforedescribed.

  9. Calculation of the ELISA's cut-off based on the change-point analysis method for detection of Trypanosoma cruzi infection in Bolivian dogs in the absence of controls.

    PubMed

    Lardeux, Frédéric; Torrico, Gino; Aliaga, Claudia

    2016-07-04

    In ELISAs, sera of individuals infected by Trypanosoma cruzi show absorbance values above a cut-off value. The cut-off is generally computed by means of formulas that need absorbance readings of negative (and sometimes positive) controls, which are included in the titer plates amongst the unknown samples. When no controls are available, other techniques should be employed such as change-point analysis. The method was applied to Bolivian dog sera processed by ELISA to diagnose T. cruzi infection. In each titer plate, the change-point analysis estimated a step point which correctly discriminated among known positive and known negative sera, unlike some of the six usual cut-off formulas tested. To analyse the ELISAs results, the change-point method was as good as the usual cut-off formula of the form "mean + 3 standard deviation of negative controls". Change-point analysis is therefore an efficient alternative method to analyse ELISA absorbance values when no controls are available.

  10. Preset pivotal tool holder

    DOEpatents

    Asmanes, Charles

    1979-01-01

    A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.

  11. Active transportation and public transportation use to achieve physical activity recommendations? A combined GPS, accelerometer, and mobility survey study.

    PubMed

    Chaix, Basile; Kestens, Yan; Duncan, Scott; Merrien, Claire; Thierry, Benoît; Pannier, Bruno; Brondeel, Ruben; Lewin, Antoine; Karusisi, Noëlla; Perchoux, Camille; Thomas, Frédérique; Méline, Julie

    2014-09-27

    Accurate information is lacking on the extent of transportation as a source of physical activity, on the physical activity gains from public transportation use, and on the extent to which population shifts in the use of transportation modes could increase the percentage of people reaching official physical activity recommendations. In 2012-2013, 234 participants of the RECORD GPS Study (French Paris region, median age = 58) wore a portable GPS receiver and an accelerometer for 7 consecutive days and completed a 7-day GPS-based mobility survey (participation rate = 57.1%). Information on transportation modes and accelerometry data aggregated at the trip level [number of steps taken, energy expended, moderate to vigorous physical activity (MVPA), and sedentary time] were available for 7,644 trips. Associations between transportation modes and accelerometer-derived physical activity were estimated at the trip level with multilevel linear models. Participants spent a median of 1 h 58 min per day in transportation (8.2% of total time). Thirty-eight per-cent of steps taken, 31% of energy expended, and 33% of MVPA over 7 days were attributable to transportation. Walking and biking trips but also public transportation trips with all four transit modes examined were associated with greater steps, MVPA, and energy expenditure when compared to trips by personal motorized vehicle. Two simulated scenarios, implying a shift of approximately 14% and 33% of all motorized trips to public transportation or walking, were associated with a predicted 6 point and 13 point increase in the percentage of participants achieving the current physical activity recommendation. Collecting data with GPS receivers, accelerometers, and a GPS-based electronic mobility survey of activities and transportation modes allowed us to investigate relationships between transportation modes and physical activity at the trip level. Our findings suggest that an increase in active transportation participation and public transportation use may have substantial impacts on the percentage of people achieving physical activity recommendations.

  12. Using appropriate body mass index cut points for overweight and obesity among Asian Americans

    PubMed Central

    Jih, Jane; Mukherjea, Arnab; Vittinghoff, Eric; Nguyen, Tung T.; Tsoh, Janice Y.; Fukuoka, Yoshimi; Bender, Melinda S.; Tseng, Winston; Kanaya, Alka M.

    2014-01-01

    Objective Asian Americans have low prevalence of overweight/obesity based on standard BMI cut points yet have higher rates of diabetes. We examined the prevalence of overweight/obesity, using lower BMI cut points recommended by the World Health Organization (WHO) for Asians, and diabetes in Asian American subgroups in California. Method Secondary analysis of the 2009 adult California Health Interview Survey (n = 45,946) of non-Hispanic Whites (NHW), African Americans, Hispanics and Asians (Vietnamese, Chinese, Korean, Filipino, South Asian and Japanese). WHO Asian BMI cut points (overweight = 23–27.5 kg/m2; obese ≥ 27.5 kg/m2) were used for Asian subgroups. Standard BMI cut points (overweight = 25–29.9 kg/m2; obese ≥ 30 kg/m2) were applied for other groups. Results Among Asian subgroups, overweight/obesity was highest among Filipinos (78.6%), which was higher than NHWs (p < 0.001) but similar to African Americans and Hispanics. Compared to NHW, diabetes prevalence was higher for Vietnamese, Koreans, Filipinos and South Asians with BMI = 23–24.9 kg/m2 and Koreans, Filipinos and Japanese with BMI = 27.5–29.9 kg/m2, the ranges WHO recommends as overweight or obese for Asians but not for other groups. Conclusions Filipinos should be a priority population for overweight/obesity screening. Filipinos, Vietnamese, Korean, South Asians and Japanese have higher diabetes prevalence at lower BMI cut points. WHO Asian BMI cut points may have clinical utility to identify at-risk Asian Americans. PMID:24736092

  13. Symptoms of distress and posttraumatic stress among South African former political detainees.

    PubMed

    Kagee, Ashraf

    2005-05-01

    Considerable debate has centred on the question of traumatisation among individuals who have survived human rights violations in societies that have undergone political conflict. In order to gain an estimate of the extent of long-term traumatisation among political activists who experienced torture and abuse in detention during the apartheid era in South Africa, a sample of 148 survivors of such experiences were recruited in a cross-sectional study and asked to complete the Hopkins Symptom Checklist (HSCL), the Impact of Event Scale (IES), and the Trauma Symptoms section of the Harvard Trauma Questionnaire (HTQ). The proportions of the sample that scored above the clinical cut-points on these measures were calculated. On the HSCL, 14.19% of the sample scored above the cut-point for clinical significance of 44; on the IES, 17.57% scored above the clinical cut-point of 44; and on the HTQ, 37.83% scored above the cut-point of 75. Moreover, the sample's mean scores were significantly higher than the cut-point for clinically significant distress on the HSCL (p < 0.001); significantly lower than the cut-point for severe traumatisation on the IES (p < 0.001); and non-significantly lower than the cut-point for clinically significant traumatisation on the HTQ (p = 0.074). These results are considered in terms of current theoretical debates on the relevance and applicability of posttraumatic stress disorder as a circumscribed nosological entity in developing countries that are in the process of coming to terms with a history of political conflict.

  14. Using appropriate body mass index cut points for overweight and obesity among Asian Americans.

    PubMed

    Jih, Jane; Mukherjea, Arnab; Vittinghoff, Eric; Nguyen, Tung T; Tsoh, Janice Y; Fukuoka, Yoshimi; Bender, Melinda S; Tseng, Winston; Kanaya, Alka M

    2014-08-01

    Asian Americans have low prevalence of overweight/obesity based on standard BMI cut points yet have higher rates of diabetes. We examined the prevalence of overweight/obesity, using lower BMI cut points recommended by the World Health Organization (WHO) for Asians, and diabetes in Asian American subgroups in California. Secondary analysis of the 2009 adult California Health Interview Survey (n=45,946) of non-Hispanic Whites (NHW), African Americans, Hispanics and Asians (Vietnamese, Chinese, Korean, Filipino, South Asian and Japanese). WHO Asian BMI cut points (overweight=23-27.5kg/m(2); obese≥27.5kg/m(2)) were used for Asian subgroups. Standard BMI cut points (overweight=25-29.9kg/m(2); obese≥30kg/m(2)) were applied for other groups. Among Asian subgroups, overweight/obesity was highest among Filipinos (78.6%), which was higher than NHWs (p<0.001) but similar to African Americans and Hispanics. Compared to NHW, diabetes prevalence was higher for Vietnamese, Koreans, Filipinos and South Asians with BMI=23-24.9kg/m(2) and Koreans, Filipinos and Japanese with BMI=27.5-29.9kg/m(2), the ranges WHO recommends as overweight or obese for Asians but not for other groups. Filipinos should be a priority population for overweight/obesity screening. Filipinos, Vietnamese, Korean, South Asians and Japanese have higher diabetes prevalence at lower BMI cut points. WHO Asian BMI cut points may have clinical utility to identify at-risk Asian Americans. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. The Current Waist Circumference Cut Point Used for the Diagnosis of Metabolic Syndrome in Sub-Saharan African Women Is Not Appropriate

    PubMed Central

    Crowther, Nigel J.; Norris, Shane A.

    2012-01-01

    The waist circumference cut point for diagnosing the metabolic syndrome in sub-Saharan African subjects is based on that obtained from studies in European populations. The aim of this study was to measure the prevalence of obesity and related metabolic disorders in an urban population of African females, a group at high risk for such diseases, and to determine the appropriate waist cut point for diagnosing the metabolic syndrome. Anthropometry and fasting lipid, glucose and insulin levels were measured in a cohort of 1251 African females participating in the Birth to Twenty cohort study in Soweto, Johannesburg. The waist circumference cut points for diagnosing metabolic syndrome (as defined using the new harmonised guidelines), insulin resistance, dysglycaemia, hypertension and dyslipidaemia were obtained using receiver operator characteristic curve analysis. The prevalence of obesity, type 2 diabetes and metabolic syndrome were 50.1%, 14.3% and 42.1%, respectively. The appropriate waist cut point for diagnosing metabolic syndrome was found to be 91.5 cm and was similar to the cuts points obtained for detecting increased risk of insulin resistance (89.0 cm), dysglycaemia (88.4 cm), hypertension (90.1 cm), hypo-high density lipoproteinaemia (87.6 cm) and hyper-low density lipoproteinaemia (90.5 cm). The present data demonstrates that urban, African females have a high prevalence of obesity and related disorders and the waist cut point currently recommended for the diagnosis of the metabolic syndrome (80.0 cm) in this population should be increased to 91.5 cm. This latter finding demonstrates a clear ethnic difference in the relationship between abdominal adiposity and metabolic disease risk. The similar waist cut points identified for the detection of the individual components of the metabolic syndrome and related cardiovascular risk factors demonstrates that the risk for different metabolic diseases increases at the same level of abdominal adiposity suggesting a common aetiological pathway. PMID:23145009

  16. Laser cutting with chemical reaction assist

    DOEpatents

    Gettemy, Donald J.

    1992-01-01

    A method for cutting with a laser beam where an oxygen-hydrocarbon reaction is used to provide auxiliary energy to a metal workpiece to supplement the energy supplied by the laser. Oxygen is supplied to the laser focus point on the workpiece by a nozzle through which the laser beam also passes. A liquid hydrocarbon is supplied by coating the workpiece along the cutting path with the hydrocarbon prior to laser irradiation or by spraying a stream of hydrocarbon through a nozzle aimed at a point on the cutting path which is just ahead of the focus point during irradiation.

  17. Laser cutting with chemical reaction assist

    DOEpatents

    Gettemy, D.J.

    1992-11-17

    A method is described for cutting with a laser beam where an oxygen-hydrocarbon reaction is used to provide auxiliary energy to a metal workpiece to supplement the energy supplied by the laser. Oxygen is supplied to the laser focus point on the workpiece by a nozzle through which the laser beam also passes. A liquid hydrocarbon is supplied by coating the workpiece along the cutting path with the hydrocarbon prior to laser irradiation or by spraying a stream of hydrocarbon through a nozzle aimed at a point on the cutting path which is just ahead of the focus point during irradiation. 1 figure.

  18. Subprimal purchasing and merchandising decisions for pork: relationship to retail value.

    PubMed

    Lorenzen, C L; Walter, J P; Dockerty, T R; Griffin, D B; Johnson, H K; Savell, J W

    1996-01-01

    To assess retail value and profitability, cutting test data were obtained in a simulated retail cutting room for boxed pork subprimals, bone-in loins (n = 180), boneless loins (n = 94), Boston butts (n = 148), fresh hams (n = 28), and boneless hams (n = 23). Processing times (seconds) and retail weights (kilograms) were used to determine relative value. Cutting style affected (P < .05) value differential (US$/subprimal) for bone-in and boneless loins. When cutting styles within subprimals were pooled, value differential was affected (P < .05) by purchasing specification for bone-in loins, boneless loins, Boston butts, and inside fresh hams. Processing bone-in loins to a boneless end point produced a greater (P < .05) value differential and percentage of gross margin than a bone-in retail end point. Bone-in loins fabricated to a boneless retail end point produced a greater (P < .05) value differential and percentage of gross margin than boneless loins fabricated to the same end point. The increase in retail value can be attributed to the increased number and weight of retail cuts produced from bone-in loins. The thick, boneless loin cutting style produced a greater (P < .05) value differential and percentage of gross margin as a result of a lower (P < .05) cost of fabrication and increased value of retail cuts than the thin, boneless cutting style. In general, boneless pork cutting methods were more profitable than bone-in cutting methods regardless of subprimal.

  19. 33 CFR 165.704 - Safety Zone; Tampa Bay, Florida.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... safety zone starts at Tampa Bay Cut “F” Channel from Lighted Buoys “3F” and “4F” and proceeds north ending at Gadsden Point Cut Lighted Buoys “3” and “4”. The safety zone starts again at Gadsden Point Cut Lighted Buoys “7” and “8” and proceeds north through Hillsborough Cut “C”, Port Sutton Entrance Channel...

  20. Metabolic Thresholds and Validated Accelerometer Cutoff Points for the Actigraph GT1M in Young Children Based on Measurements of Locomotion and Play Activities

    ERIC Educational Resources Information Center

    Jimmy, Gerda; Dossegger, Alain; Seiler, Roland; Mader, Urs

    2012-01-01

    The purpose of the current study was to determine metabolic thresholds and subsequent activity intensity cutoff points for the ActiGraph GT1M with various epochs spanning from 5 to 60 sec in young children. Twenty-two children, aged 4 to 9 years, performed 10 different activities including locomotion and play activities. Energy expenditure was…

  1. High performance, accelerometer-based control of the Mini-MAST structure at Langley Research Center

    NASA Technical Reports Server (NTRS)

    Collins, Emmanuel G., Jr.; King, James A.; Phillips, Douglas J.; Hyland, David C.

    1991-01-01

    Many large space system concepts will require active vibration control to satisfy critical performance requirements such as line of sight pointing accuracy and constraints on rms surface roughness. In order for these concepts to become operational, it is imperative that the benefits of active vibration control be shown to be practical in ground based experiments. The results of an experiment shows the successful application of the Maximum Entropy/Optimal Projection control design methodology to active vibration control for a flexible structure. The testbed is the Mini-Mast structure at NASA-Langley and has features dynamically traceable to future space systems. To maximize traceability to real flight systems, the controllers were designed and implemented using sensors (four accelerometers and one rate gyro) that are actually mounted to the structure. Ground mounted displacement sensors that could greatly ease the control design task were available but were used only for performance evaluation. The use of the accelerometers increased the potential of destabilizing the system due to spillover effects and motivated the use of precompensation strategy to achieve sufficient compensator roll-off.

  2. High performance, accelerometer-based control of the Mini-MAST structure

    NASA Technical Reports Server (NTRS)

    Collins, Emmanuel G., Jr.; King, James A.; Phillips, Douglas J.; Hyland, David C.

    1992-01-01

    Many large space system concepts will require active vibration control to satisfy critical performance requirements such as line of sight pointing accuracy and constraints on rms surface roughness. In order for these concepts to become operational, it is imperative that the benefits of active vibration control be shown to be practical in ground based experiments. The results of an experiment shows the successful application of the Maximum Entropy/Optical Projection control design methodology to active vibration control for a flexible structure. The testbed is the Mini-Mast structure at NASA-Langley and has features dynamically traceable to future space systems. To maximize traceability to real flight systems, the controllers were designed and implemented using sensors (four accelerometers and one rate gyro) that are actually mounted to the structure. Ground mounted displacement sensors that could greatly ease the control design task were available but were used only for performance evaluation. The use of the accelerometers increased the potential of destabilizing the system due to spillover effects and motivated the use of precompensation strategy to achieve sufficient compensator roll-off.

  3. Validity and reliability of the Physical Activity Questionnaire for Children (PAQ-C) and Adolescents (PAQ-A) in individuals with congenital heart disease

    PubMed Central

    Dean, Paige H.; Gardner, Ross F.; Duncombe, Stephanie L.; Harris, Kevin C.

    2017-01-01

    Objective To assess the criterion validity, internal consistency, reliability and cut-point for the Physical Activity Questionnaire for Children (PAQ-C) and Adolescents (PAQ-A) in children and adolescents with congenital heart disease–a special population at high cardiovascular risk in whom physical activity has not been extensively evaluated. Methods We included 84 participants (13.6±2.9 yrs, 50% female) with simple (37%), moderate (31%), or severe congenital heart disease (27%), as well as cardiac transplant recipients (6%), from BC Children’s Hospital, Canada. They completed the PAQ-C (≤11yrs, n = 28) or–A (≥12yrs, n = 56), and also wore a triaxial accelerometer (GT3X+ or GT9X) over the right hip for 7 days (n = 59 met valid wear time criteria). Results Median daily moderate-to-vigorous physical activity was 46.9 minutes per day (IQR 31.6–61.8) and 25% met physical activity guidelines defined as ≥60 minutes of moderate-to-vigorous physical activity per day. Median PAQ-score was 2.6 (IQR 1.9–3.0). PAQ-Scores were significantly related to accelerometry-derived metrics of physical activity (rho = 0.44–0.55, all p<0.01) and sedentary behaviour (rho = -0.53, p<0.001). Internal consistency was high (α = 0.837), as was reliability (stability) of PAQ-Scores over a 4-months period (ICC = 0.73, 95%CI 0.55–0.84; p<0.001). We identified that a PAQ-Score cut-point of 2.87 discriminates between those meeting physical guidelines and those that do not in the combined PAQ-C and–A samples (area under the curve = 0.80 (95%CI 0.67–0.92). Conclusion Validity and reliability of the PAQ in children and adolescents with CHD was comparable to or stronger than previous studies in healthy children. Therefore, the PAQ may be used to estimate general levels of physical activity in children and adolescents with CHD. PMID:28445485

  4. Simplified design of diaphragm-based fiber optic extrinsic Fabry-Perot accelerometer

    NASA Astrophysics Data System (ADS)

    Wang, Zhaogang; Zhang, Wentao; Han, Jing; Huang, Wenzhu; Li, Fang

    2014-11-01

    A fiber optic Fabry-Perot accelerometer (FOFPA) with diaphragm-mass-collimator (DMC) gathered structure is presented. This design makes the structure more compacts and the manufacturing process more controllable. The operation principle based on Fabry-Perot interference is described. Several tests using intensity demodulation scheme which can control the working point of FOFPA were carried out. Experimental results show that: axis sensitivity of the proposed FOFPA is 36.07 dB (re: 0 dB=1 V/g) with a fluctuation less than 0.9 dB in a frequency bandwidth of 10-125 Hz, the resonant frequency is about 350 Hz, measurement range is about 70 dB@100 Hz. which are much close to theoretical values

  5. Inertial Sensor Assisted Acquisition, Tracking, and Pointing for High Data Rate Free Space Optical Communications

    NASA Technical Reports Server (NTRS)

    Lee, Shinhak; Ortiz, Gerry G.

    2003-01-01

    We discuss use of inertial sensors to facilitate deep space optical communications. Implementation of this concept requires accurate and wide bandwidth inertial sensors. In this presentation, the principal concept and algorithm using linear accelerometers will be given along with the simulation and experimental results.

  6. Posturography and locomotor tests of dynamic balance after long-duration spaceflight.

    PubMed

    Cohen, Helen S; Kimball, Kay T; Mulavara, Ajitkumar P; Bloomberg, Jacob J; Paloski, William H

    2012-01-01

    The currently approved objective clinical measure of standing balance in astronauts after space flight is the Sensory Organization Test battery of computerized dynamic posturography. No tests of walking balance are currently approved for standard clinical testing of astronauts. This study determined the sensitivity and specificity of standing and walking balance tests for astronauts before and after long-duration space flight. Astronauts were tested on an obstacle avoidance test known as the Functional Mobility Test (FMT) and on the Sensory Organization Test using sway-referenced support surface motion with eyes closed (SOT 5) before and six months after (n=15) space flight on the International Space Station. They were tested two to seven days after landing. Scores on SOT tests decreased and scores on FMT increased significantly from pre- to post-flight. In other words, post-flight scores were worse than pre-flight scores. SOT and FMT scores were not significantly related. ROC analyses indicated supra-clinical cut-points for SOT 5 and for FMT. The standard clinical cut-point for SOT 5 had low sensitivity to post-flight astronauts. Higher cut-points increased sensitivity to post-flight astronauts but decreased specificity to pre-flight astronauts. Using an FMT cut-point that was moderately highly sensitive and highly specific plus SOT 5 at the standard clinical cut-point was no more sensitive than SOT 5, alone. FMT plus SOT 5 at higher cut-points was more specific and more sensitive. The total correctly classified was highest for FMT, alone, and for FMT plus SOT 5 at the highest cut-point. These findings indicate that standard clinical comparisons are not useful for identifying problems. Testing both standing and walking balance will be more likely to identify balance deficits.

  7. Body mass index cut-points to identify cardiometabolic risk in black South Africans.

    PubMed

    Kruger, H Salome; Schutte, Aletta E; Walsh, Corinna M; Kruger, Annamarie; Rennie, Kirsten L

    2017-02-01

    To determine optimal body mass index (BMI) cut-points for the identification of cardiometabolic risk in black South African adults. We performed a cross-sectional study of a weighted sample of healthy black South Africans aged 25-65 years (721 men, 1386 women) from the North West and Free State Provinces. Demographic, lifestyle and anthropometric measures were taken, and blood pressure, fasting serum triglycerides, high-density lipoprotein (HDL) cholesterol and blood glucose were measured. We defined elevated cardiometabolic risk as having three or more risk factors according to international metabolic syndrome criteria. Receiver operating characteristic curves were applied to identify an optimal BMI cut-point for men and women. BMI had good diagnostic performance to identify clustering of three or more risk factors, as well as individual risk factors: low HDL-cholesterol, elevated fasting glucose and triglycerides, with areas under the curve >.6, but not for high blood pressure. Optimal BMI cut-points averaged 22 kg/m 2 for men and 28 kg/m 2 for women, respectively, with better sensitivity in men (44.0-71.9 %), and in women (60.6-69.8 %), compared to a BMI of 30 kg/m 2 (17-19.1, 53-61.4 %, respectively). Men and women with a BMI >22 and >28 kg/m 2 , respectively, had significantly increased probability of elevated cardiometabolic risk after adjustment for age, alcohol use and smoking. In black South African men, a BMI cut-point of 22 kg/m 2 identifies those at cardiometabolic risk, whereas a BMI of 30 kg/m 2 underestimates risk. In women, a cut-point of 28 kg/m 2 , approaching the WHO obesity cut-point, identifies those at risk.

  8. Automatic micropropagation of plants--the vision-system: graph rewriting as pattern recognition

    NASA Astrophysics Data System (ADS)

    Schwanke, Joerg; Megnet, Roland; Jensch, Peter F.

    1993-03-01

    The automation of plant-micropropagation is necessary to produce high amounts of biomass. Plants have to be dissected on particular cutting-points. A vision-system is needed for the recognition of the cutting-points on the plants. With this background, this contribution is directed to the underlying formalism to determine cutting-points on abstract-plant models. We show the usefulness of pattern recognition by graph-rewriting along with some examples in this context.

  9. Prevalence of energy intake misreporting in Malay children varies based on application of different cut points.

    PubMed

    Yang, Wai Yew; Burrows, Tracy; Collins, Clare E; MacDonald-Wicks, Lesley; Williams, Lauren T; Chee, Winnie Siew Swee

    2014-12-01

    This study aimed to identify the prevalence of energy misreporting amongst a sample of Malay children aged 9-11 years (n = 14) using a range of commonly used cut points. Participants were interviewed using repeated 24 h dietary recalls over three occasions. The Goldberg equations (1991 and 2000), Torun cut points and the Black and Cole method were applied to the data. Up to 11 of 14 children were classified as misreporters, with more under-reporters (between seven and eight children) than over-reporters (four or less children). There were significant differences in the proportion of children classified as energy misreporters when applying basal metabolic rate calculated using FAO/UNU/WHO (1985) and Malaysian-specific equations (p < 0.05). The results show that energy misreporting is common amongst Malay children, varying according to cut point chosen. Objective evaluation of total energy expenditure would help identify which cut point is appropriate for use in Malay paediatric populations. © The Author [2014]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Physical activity and post-treatment weight trajectory in anorexia nervosa

    PubMed Central

    Gianini, Loren M; Klein, Diane A; Call, Christine; Walsh, B. Timothy; Wang, Yuanjia; Wu, Peng; Attia, Evelyn

    2015-01-01

    Objective This study compared an objective measurement of physical activity (PA) in individuals with anorexia nervosa (AN) at low-weight, weight-restored, and post-treatment time points, and also compared PA in AN with that of healthy controls (HC). Method Sixty-one female inpatients with AN wore a novel accelerometer (the IDEEA) which measured PA at three time points: a) low-weight, b) weight-restored, and c) one month post-hospital discharge. Twenty-four HCs wore the IDEEA at one time point. Results Inpatients with AN became more physically active than they were at low-weight at weight restoration and following treatment discharge. Post-treatment patients with AN were more physically active than HCs during the day and less active at night, which was primarily accounted for by amount of time spent on feet, including standing and walking. Greater time spent on feet during the weight-restoration time point of inpatient treatment was associated with more rapid decrease in BMI over the 12 months following treatment discharge. Fidgeting did not differ between patients and controls, did not change with weight restoration, and did not predict post-treatment weight change. Discussion Use of a novel accelerometer demonstrated greater PA in AN than in healthy controls. PA following weight restoration in AN, particularly time spent in standing postures, may contribute to weight loss in the year following hospitalization. PMID:26712105

  11. Effectiveness of the CANRISK tool in the identification of dysglycemia in First Nations and Métis in Canada

    PubMed Central

    Gina, Agarwal; Ying, Jiang; Susan, Rogers Van Katwyk; Chantal, Lemieux; Heather, Orpana; Yang, Mao; Brandan, Hanley; Karen, Davis; Laurel, Leuschen; Howard, Morrison

    2018-01-01

    Abstract Introduction: First Nations/Métis populations develop diabetes earlier and at higher rates than other Canadians. The Canadian diabetes risk questionnaire (CANRISK) was developed as a diabetes screening tool for Canadians aged 40 years or over. The primary aim of this paper is to assess the effectiveness of the existing CANRISK tool and risk scores in detecting dysglycemia in First Nations/Métis participants, including among those under the age of 40. A secondary aim was to determine whether alternative waist circumference (WC) and body mass index (BMI) cut-off points improved the predictive ability of logistic regression models using CANRISK variables to predict dysglycemia. Methods: Information from a self-administered CANRISK questionnaire, anthropometric measurements, and results of a standard oral glucose tolerance test (OGTT) were collected from First Nations and Métis participants (n = 1479). Sensitivity and specificity of CANRISK scores using published risk score cut-off points were calculated. Logistic regression was conducted with alternative ethnicity-specific BMI and WC cut-off points to predict dysglycemia using CANRISK variables. Results: Compared with OGTT results, using a CANRISK score cut-off point of 33, the sensitivity and specificity of CANRISK was 68% and 63% among individuals aged 40 or over; it was 27% and 87%, respectively among those under 40. Using a lower cut-off point of 21, the sensitivity for individuals under 40 improved to 77% with a specificity of 44%. Though specificity at this threshold was low, the higher level of sensitivity reflects the importance of the identification of high risk individuals in this population. Despite altered cut-off points of BMI and WC, logistic regression models demonstrated similar predictive ability. Conclusion: CANRISK functioned well as a preliminary step for diabetes screening in a broad age range of First Nations and Métis in Canada, with an adjusted CANRISK cutoff point for individuals under 40, and with no incremental improvement from using alternative BMI/WC cut-off points. PMID:29443485

  12. Fabrication of a Miniaturized ZnO Nanowire Accelerometer and Its Performance Tests

    PubMed Central

    Kim, Hyun Chan; Song, Sangho; Kim, Jaehwan

    2016-01-01

    This paper reports a miniaturized piezoelectric accelerometer suitable for a small haptic actuator array. The accelerometer is made with zinc oxide (ZnO) nanowire (NW) grown on a copper wafer by a hydrothermal process. The size of the accelerometer is 1.5 × 1.5 mm2, thus fitting the 1.8 × 1.8 mm2 haptic actuator array cell. The detailed fabrication process of the miniaturized accelerometer is illustrated. Performance evaluation of the fabricated accelerometer is conducted by comparing it with a commercial piezoelectric accelerometer. The output current of the fabricated accelerometer increases linearly with the acceleration. The miniaturized ZnO NW accelerometer is feasible for acceleration measurement of small and lightweight devices. PMID:27649184

  13. Cut-Off Points for Mild, Moderate, and Severe Pain on the Numeric Rating Scale for Pain in Patients with Chronic Musculoskeletal Pain: Variability and Influence of Sex and Catastrophizing.

    PubMed

    Boonstra, Anne M; Stewart, Roy E; Köke, Albère J A; Oosterwijk, René F A; Swaan, Jeannette L; Schreurs, Karlein M G; Schiphorst Preuper, Henrica R

    2016-01-01

    Objectives: The 0-10 Numeric Rating Scale (NRS) is often used in pain management. The aims of our study were to determine the cut-off points for mild, moderate, and severe pain in terms of pain-related interference with functioning in patients with chronic musculoskeletal pain, to measure the variability of the optimal cut-off points, and to determine the influence of patients' catastrophizing and their sex on these cut-off points. Methods: 2854 patients were included. Pain was assessed by the NRS, functioning by the Pain Disability Index (PDI) and catastrophizing by the Pain Catastrophizing Scale (PCS). Cut-off point schemes were tested using ANOVAs with and without using the PSC scores or sex as co-variates and with the interaction between CP scheme and PCS score and sex, respectively. The variability of the optimal cut-off point schemes was quantified using bootstrapping procedure. Results and conclusion: The study showed that NRS scores ≤ 5 correspond to mild, scores of 6-7 to moderate and scores ≥8 to severe pain in terms of pain-related interference with functioning. Bootstrapping analysis identified this optimal NRS cut-off point scheme in 90% of the bootstrapping samples. The interpretation of the NRS is independent of sex, but seems to depend on catastrophizing. In patients with high catastrophizing tendency, the optimal cut-off point scheme equals that for the total study sample, but in patients with a low catastrophizing tendency, NRS scores ≤ 3 correspond to mild, scores of 4-6 to moderate and scores ≥7 to severe pain in terms of interference with functioning. In these optimal cut-off schemes, NRS scores of 4 and 5 correspond to moderate interference with functioning for patients with low catastrophizing tendency and to mild interference for patients with high catastrophizing tendency. Theoretically one would therefore expect that among the patients with NRS scores 4 and 5 there would be a higher average PDI score for those with low catastrophizing than for those with high catastrophizing. However, we found the opposite. The fact that we did not find the same optimal CP scheme in the subgroups with lower and higher catastrophizing tendency may be due to chance variability.

  14. Cut-Off Points for Mild, Moderate, and Severe Pain on the Numeric Rating Scale for Pain in Patients with Chronic Musculoskeletal Pain: Variability and Influence of Sex and Catastrophizing

    PubMed Central

    Boonstra, Anne M.; Stewart, Roy E.; Köke, Albère J. A.; Oosterwijk, René F. A.; Swaan, Jeannette L.; Schreurs, Karlein M. G.; Schiphorst Preuper, Henrica R.

    2016-01-01

    Objectives: The 0–10 Numeric Rating Scale (NRS) is often used in pain management. The aims of our study were to determine the cut-off points for mild, moderate, and severe pain in terms of pain-related interference with functioning in patients with chronic musculoskeletal pain, to measure the variability of the optimal cut-off points, and to determine the influence of patients’ catastrophizing and their sex on these cut-off points. Methods: 2854 patients were included. Pain was assessed by the NRS, functioning by the Pain Disability Index (PDI) and catastrophizing by the Pain Catastrophizing Scale (PCS). Cut-off point schemes were tested using ANOVAs with and without using the PSC scores or sex as co-variates and with the interaction between CP scheme and PCS score and sex, respectively. The variability of the optimal cut-off point schemes was quantified using bootstrapping procedure. Results and conclusion: The study showed that NRS scores ≤ 5 correspond to mild, scores of 6–7 to moderate and scores ≥8 to severe pain in terms of pain-related interference with functioning. Bootstrapping analysis identified this optimal NRS cut-off point scheme in 90% of the bootstrapping samples. The interpretation of the NRS is independent of sex, but seems to depend on catastrophizing. In patients with high catastrophizing tendency, the optimal cut-off point scheme equals that for the total study sample, but in patients with a low catastrophizing tendency, NRS scores ≤ 3 correspond to mild, scores of 4–6 to moderate and scores ≥7 to severe pain in terms of interference with functioning. In these optimal cut-off schemes, NRS scores of 4 and 5 correspond to moderate interference with functioning for patients with low catastrophizing tendency and to mild interference for patients with high catastrophizing tendency. Theoretically one would therefore expect that among the patients with NRS scores 4 and 5 there would be a higher average PDI score for those with low catastrophizing than for those with high catastrophizing. However, we found the opposite. The fact that we did not find the same optimal CP scheme in the subgroups with lower and higher catastrophizing tendency may be due to chance variability. PMID:27746750

  15. 50 CFR Figures 18a, 18b and 18c to... - Large Frame TED Escape Opening; Minimum Dimensions Using All-Bar Cuts (Triangular Cuts); Large...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Dimensions Using All-Bar Cuts (Triangular Cuts); Large Frame TED Escape Opening; Minimum Dimensions Using All-Bar Cuts and Leading Edge Cut; Large Frame TED Escape Opening; Minimum Dimensions Using All-Points...—Large Frame TED Escape Opening; Minimum Dimensions Using All-Bar Cuts (Triangular Cuts); Large Frame TED...

  16. 50 CFR Figures 18a, 18b and 18c to... - Large Frame TED Escape Opening; Minimum Dimensions Using All-Bar Cuts (Triangular Cuts); Large...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Dimensions Using All-Bar Cuts (Triangular Cuts); Large Frame TED Escape Opening; Minimum Dimensions Using All-Bar Cuts and Leading Edge Cut; Large Frame TED Escape Opening; Minimum Dimensions Using All-Points...—Large Frame TED Escape Opening; Minimum Dimensions Using All-Bar Cuts (Triangular Cuts); Large Frame TED...

  17. 50 CFR Figures 18a, 18b and 18c to... - Large Frame TED Escape Opening; Minimum Dimensions Using All-Bar Cuts (Triangular Cuts); Large...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Dimensions Using All-Bar Cuts (Triangular Cuts); Large Frame TED Escape Opening; Minimum Dimensions Using All-Bar Cuts and Leading Edge Cut; Large Frame TED Escape Opening; Minimum Dimensions Using All-Points...—Large Frame TED Escape Opening; Minimum Dimensions Using All-Bar Cuts (Triangular Cuts); Large Frame TED...

  18. On-Orbit Gradiometry with the scientific instrument of the French Space Mission MICROSCOPE

    NASA Astrophysics Data System (ADS)

    Foulon, B.; Baghi, Q.; Panet, I.; Rodrigues, M.; Metris, G.; Touboul, P.

    2017-12-01

    The MICROSCOPE mission is fully dedicated to the in-orbit test of the universality of free fall, the so-called Weak Equivalence Principle (WEP). Based on a CNES Myriade microsatellite launched on the 25th of April 2016, MICROSCOPE is a CNES-ESA-ONERA-CNRS-OCA mission, the scientific objective of which is to test of the Equivalence Principle with an extraordinary accuracy at the level of 10-15. The measurement will be obtained from the T-SAGE (Twin Space Accelerometer for Gravitational Experimentation) instrument constituted by two ultrasensitive differential accelerometers. One differential electrostatic accelerometer, labeled SU-EP, contains, at its center, two proof masses made of Titanium and Platinum and is used for the test. The twin accelerometer, labeled SU-REF, contains two Platinum proof masses and is used as a reference instrument. Separated by a 17 cm-length arm, they are embarked in a very stable and soft environment on board a satellite equipped with a drag-free control system and orbiting on a sun synchronous circular orbit at 710 km above the Earth. In addition to the WEP test, this configuration can be interesting for various applications, and one of the proposed ideas is to use MICROSCOPE data for the measurement of Earth's gravitational gradient. Considering the gradiometer formed by the inner Platinum proof-masses of the two differential accelerometers and the arm along the Y-axis of the instrument which is perpendicular to the orbital plane, possibly 3 components of the gradient can be measured: Txy, Tyy and Tzy. Preliminary studies suggest that the errors can be lower than 10mE. Taking advantage of its higher altitude with respect to GOCE, the low frequency signature of Earth's potential seen by MICROSCOPE could provide an additional observable in gradiometry to discriminate between different models describing the large scales of the mass distribution in the Earth's deep mantle. The poster will shortly present the MICROSCOPE mission configuration. It will detail the actual in-flight performances of the accelerometers and of the attitude and position control, in order to evaluate the gradiometer error budget according to the satellite pointing mode configuration.

  19. Online machining error estimation method of numerical control gear grinding machine tool based on data analysis of internal sensors

    NASA Astrophysics Data System (ADS)

    Zhao, Fei; Zhang, Chi; Yang, Guilin; Chen, Chinyin

    2016-12-01

    This paper presents an online estimation method of cutting error by analyzing of internal sensor readings. The internal sensors of numerical control (NC) machine tool are selected to avoid installation problem. The estimation mathematic model of cutting error was proposed to compute the relative position of cutting point and tool center point (TCP) from internal sensor readings based on cutting theory of gear. In order to verify the effectiveness of the proposed model, it was simulated and experimented in gear generating grinding process. The cutting error of gear was estimated and the factors which induce cutting error were analyzed. The simulation and experiments verify that the proposed approach is an efficient way to estimate the cutting error of work-piece during machining process.

  20. Statistical approaches for the determination of cut points in anti-drug antibody bioassays.

    PubMed

    Schaarschmidt, Frank; Hofmann, Matthias; Jaki, Thomas; Grün, Bettina; Hothorn, Ludwig A

    2015-03-01

    Cut points in immunogenicity assays are used to classify future specimens into anti-drug antibody (ADA) positive or negative. To determine a cut point during pre-study validation, drug-naive specimens are often analyzed on multiple microtiter plates taking sources of future variability into account, such as runs, days, analysts, gender, drug-spiked and the biological variability of un-spiked specimens themselves. Five phenomena may complicate the statistical cut point estimation: i) drug-naive specimens may contain already ADA-positives or lead to signals that erroneously appear to be ADA-positive, ii) mean differences between plates may remain after normalization of observations by negative control means, iii) experimental designs may contain several factors in a crossed or hierarchical structure, iv) low sample sizes in such complex designs lead to low power for pre-tests on distribution, outliers and variance structure, and v) the choice between normal and log-normal distribution has a serious impact on the cut point. We discuss statistical approaches to account for these complex data: i) mixture models, which can be used to analyze sets of specimens containing an unknown, possibly larger proportion of ADA-positive specimens, ii) random effects models, followed by the estimation of prediction intervals, which provide cut points while accounting for several factors, and iii) diagnostic plots, which allow the post hoc assessment of model assumptions. All methods discussed are available in the corresponding R add-on package mixADA. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. A field test of cut-off importance sampling for bole volume

    Treesearch

    Jeffrey H. Gove; Harry T. Valentine; Michael J. Holmes

    2000-01-01

    Cut-off importance sampling has recently been introduced as a technique for estimating bole volume to some point below the tree tip, termed the cut-off point. A field test of this technique was conducted on a small population of eastern white pine trees using dendrometry as the standard for volume estimation. Results showed that the differences in volume estimates...

  2. 33 CFR 165.704 - Safety Zone; Tampa Bay, Florida.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., Florida. (a) A floating safety zone is established consisting of an area 1000 yards fore and aft of a... ending at Gadsden Point Cut Lighted Buoys “3” and “4”. The safety zone starts again at Gadsden Point Cut... the marked channel at Tampa Bay Cut “K” buoy “11K” enroute to Rattlesnake, Tampa, FL, the floating...

  3. Dental cutting behaviour of mica-based and apatite-based machinable glass-ceramics.

    PubMed

    Taira, M; Wakasa, K; Yamaki, M; Matsui, A

    1990-09-01

    Some recently developed industrial ceramics have excellent machinability properties. The objective of this study was to evaluate the dental cutting behaviour of two machinable glass-ceramics, mica-containing Macor-M and apatite- and diopside-containing Bioram-M, and to compare them with the cutting behaviour of a composite resin typodont tooth enamel and bovine enamel. Weight-load cutting tests were conducted, using a diamond point driven by an air-turbine handpiece, While the transverse load applied on the point was varied, the handpiece speed during cutting and the volume of removal upon cutting were measured. In general, an increase in the applied load caused a decrease in cutting speed and an increase in cutting volume. However, the intensity of this trend was found to differ between four workpieces. Cutting Macor-M resulted in the second-most reduced cutting speed and the maximum cutting volume. Cutting Bioram-M gave the least reduced cutting speed and the minimum cutting volume. It was suggested that two machinable glass-ceramics could be employed as typodont teeth. This study may also contribute to the development of new restorative dental ceramic materials, prepared by machining.

  4. Sensitivity and specificity of the body mass index for the diagnosis of overweight/obesity in elderly.

    PubMed

    Vasconcelos, Francisco de Assis Guedes de; Cordeiro, Braian Alves; Rech, Cassiano Ricardo; Petroski, Edio Luiz

    2010-08-01

    The aim of this article was to verify the sensitivity and specificity of the body mass index (BMI) cut-off points proposed by the World Health Organization (WHO) and the Nutrition Screening Initiative (NSI) for the diagnosis of obesity in the elderly. A cross-sectional study was made with 180 healthy elderly subjects from Florianópolis, Santa Catarina State, Brazil. Body fat percentage (%BF) was determined using DEXA (dual energy X-ray absorptiometry). The BMI cut-off point of the NSI offers better sensitivity and specificity for men (73.7% and 72.5% respectively). For women, the lower the cut-off point the better the sensitivity, with a BMI of 25kg/m² (sensitivity of 76.3% and specificity of 100%) being the most accurate for diagnosing obesity in elderly women. The WHO cut-off point offered very low sensitivity (28.9%). The results of this investigation lead to the conclusion that the cut-off points proposed by the WHO and the ones adopted by the NSI and by Lipschitz are not good indicators of obesity for the elderly of either sex, since they offer low sensitivity.

  5. Arbovirus models to provide practical management tools for mosquito control and disease prevention in the Northern Territory, Australia.

    PubMed

    Jacups, Susan P; Whelan, Peter I; Harley, David

    2011-03-01

    Ross River virus (RRV) causes the most common human arbovirus disease in Australia. Although the disease is nonfatal, the associated arthritis and postinfection fatigue can be debilitating for many months, impacting on workforce participation. We sought to create an early-warning system to notify of approaching RRV disease outbreak conditions for major townships in the Northern Territory. By applying a logistic regression model to meteorologic factors, including rainfall, a postestimation analysis of sensitivity and specificity can create rainfall cut-points. These rainfall cut-points indicate the rainfall level above which previous epidemic conditions have occurred. Furthermore, rainfall cut-points indirectly adjust for vertebrate host data from the agile wallaby (Macropus agilis) as the life cycle of the agile wallaby is intricately meshed with the wet season. Once generated, cut-points can thus be used prospectively to allow timely implementation of larval survey and control measures and public health warnings to preemptively reduce RRV disease incidence. Cut-points are location specific and have the capacity to replace previously used models, which require data management and input, and rarely provide timely notification for vector control requirements and public health warnings. These methods can be adapted for use elsewhere.

  6. Research on subsurface deformed layer in ultra-precision cutting of single crystal copper by focused ion beam etching method

    NASA Astrophysics Data System (ADS)

    Chen, Y.; Huang, X. J.; Kong, J. X.

    2018-03-01

    In this paper, the focused ion beam was used to study the subsurface deformed layer of single crystal copper caused by the nanoscale single-point diamond fly cutting, and the possibility of using nanometer ultra-precision cutting to remove the larger deformation layer caused by traditional rough cutting process was explored. The maximum cutting thickness of single-point diamond cutting was about 146 nm, and the surface of the single-crystal copper after cutting was etched and observed by using the focused ion beam method. It was found that the morphology of the near-surface layer and the intermediate layer of the copper material were larger differences: the near-surface of the material was smaller and more compact, and the intermediate material layer of the material was more coarse sparse. The results showed that the traditional precision cutting would residual significant subsurface deformed layer and the thickness was on micron level. Even more, the subsurface deformed layer was obviously removed from about 12μm to 5μm after single-point diamond fly cutting in this paper. This paper proved that the large-scale subsurface deformed layer caused by traditional cutting process could be removed by nanometer ultra-precision cutting. It was of great significance to further establish the method that control of the deformation of weak rigid components by reducing the depth of the subsurface deformed layers.

  7. A Novel Mobile Testing Equipment for Rock Cuttability Assessment: Vertical Rock Cutting Rig (VRCR)

    NASA Astrophysics Data System (ADS)

    Yasar, Serdar; Yilmaz, Ali Osman

    2017-04-01

    In this study, a new mobile rock cutting testing apparatus was designed and produced for rock cuttability assessment called vertical rock cutting rig (VRCR) which was designed specially to fit into hydraulic press testing equipment which are available in almost every rock mechanics laboratory. Rock cutting trials were initiated just after the production of VRCR along with calibration of the measuring load cell with an external load cell to validate the recorded force data. Then, controlled rock cutting tests with both relieved and unrelieved cutting modes were implemented on five different volcanic rock samples with a standard simple-shaped wedge tool. Additionally, core cutting test which is an important approach for roadheader performance prediction was simulated with VRCR. Mini disc cutters and point attack tools were used for execution of experimental trials. Results clearly showed that rock cutting tests were successfully realized and measuring system is delicate to rock strength, cutting depth and other variables. Core cutting test was successfully simulated, and it was also shown that rock cutting tests with mini disc cutters and point attack tools are also successful with VRCR.

  8. The Glittre-ADL Test Cut-Off Point to Discriminate Abnormal Functional Capacity in Patients with COPD.

    PubMed

    Gulart, Aline Almeida; Munari, Anelise Bauer; Klein, Suelen Roberta; Santos da Silveira, Lucas; Mayer, Anamaria Fleig

    2018-02-01

    The study objective was to determine a cut-off point for the Glittre activities of daily living (ADL)test (TGlittre) to discriminate patients with normal and abnormal functional capacity. Fifty-nine patients with moderate to very severe COPD (45 males; 65 ± 8.84 years; BMI: 26 ± 4.78 kg/m 2 ; FEV 1 : 35.3 ± 13.4% pred) were evaluated for spirometry, TGlittre, 6-minute walk test (6 MWT), physical ADL, modified Medical Research Council scale (mMRC), BODE index, Saint George's Respiratory Questionnaire (SGRQ), and COPD Assessment Test (CAT). The receiver operating characteristic (ROC) curve was used to determine the cut-off point for TGlittre in order to discriminate patients with 6 MWT < 82% pred. The ROC curve indicated a cut-off point of 3.5 minutes for the TGlittre (sensitivity = 92%, specificity = 83%, and area under the ROC curve = 0.95 [95% CI: 0.89-0.99]). Patients with abnormal functional capacity had higher mMRC (median difference 1 point), CAT (mean difference: 4.5 points), SGRQ (mean difference: 12.1 points), and BODE (1.37 points) scores, longer time of physical activity <1.5 metabolic equivalent of task (mean difference: 47.9 minutes) and in sitting position (mean difference: 59.4 minutes) and smaller number of steps (mean difference: 1,549 minutes); p < 0.05 for all. In conclusion, the cut-off point of 3.5 minutes in the TGlittre is sensitive and specific to distinguish COPD patients with abnormal and normal functional capacity.

  9. Development of a computer method for predicting lumber cutting yields.

    Treesearch

    Daniel E. Dunmire; George H. Englerth

    1967-01-01

    A system of locating defects in a board by intersecting coordinate points was developed and a computer program devised that used these points to locate all possible clear areas in the board. The computer determined the yields by placing any given size or sizes of cuttings in these clear areas, and furthermore stated the type, location, and number of saw cuts. The...

  10. Estimation of the laser cutting operating cost by support vector regression methodology

    NASA Astrophysics Data System (ADS)

    Jović, Srđan; Radović, Aleksandar; Šarkoćević, Živče; Petković, Dalibor; Alizamir, Meysam

    2016-09-01

    Laser cutting is a popular manufacturing process utilized to cut various types of materials economically. The operating cost is affected by laser power, cutting speed, assist gas pressure, nozzle diameter and focus point position as well as the workpiece material. In this article, the process factors investigated were: laser power, cutting speed, air pressure and focal point position. The aim of this work is to relate the operating cost to the process parameters mentioned above. CO2 laser cutting of stainless steel of medical grade AISI316L has been investigated. The main goal was to analyze the operating cost through the laser power, cutting speed, air pressure, focal point position and material thickness. Since the laser operating cost is a complex, non-linear task, soft computing optimization algorithms can be used. Intelligent soft computing scheme support vector regression (SVR) was implemented. The performance of the proposed estimator was confirmed with the simulation results. The SVR results are then compared with artificial neural network and genetic programing. According to the results, a greater improvement in estimation accuracy can be achieved through the SVR compared to other soft computing methodologies. The new optimization methods benefit from the soft computing capabilities of global optimization and multiobjective optimization rather than choosing a starting point by trial and error and combining multiple criteria into a single criterion.

  11. Age-related differences in recommended anthropometric cut-off point validity to identify cardiovascular risk factors in ostensibly healthy women

    PubMed Central

    Björkelund, Cecilia; Guo, Xinxin; Skoog, Ingmar; Bosaeus, Ingvar; Lissner, Lauren

    2014-01-01

    Aim: To investigate validity of widely recommended anthropometric and total fat percentage cut-off points in screening for cardiovascular risk factors in women of different ages. Methods: A population-based sample of 1002 Swedish women aged 38, 50, 75 (younger, middle-aged and elderly, respectively) underwent anthropometry, health examinations and blood tests. Total fat was estimated (bioimpedance) in 670 women. Sensitivity, specificity of body mass index (BMI; ≥25 and ≥30), waist circumference (WC; ≥80 cm and ≥88 cm) and total fat percentage (TF; ≥35%) cut-off points for cardiovascular risk factors (dyslipidaemias, hypertension and hyperglycaemia) were calculated for each age. Cut-off points yielding high sensitivity together with modest specificity were considered valid. Women reporting hospital admission for cardiovascular disease were excluded. Results: The sensitivity of WC ≥80 cm for one or more risk factors was ~60% in younger and middle-aged women, and 80% in elderly women. The specificity of WC ≥80 cm for one or more risk factors was 69%, 57% and 40% at the three ages (p < .05 for age trends). WC ≥80 cm yielded ~80% sensitivity for two or more risk factors across all ages. However, specificity decreased with increasing age (p < .0001), being 33% in elderly. WC ≥88 cm provided better specificity in elderly women. BMI and TF % cut-off points were not better than WC. Conclusions: Validity of recommended anthropometric cut-off points in screening asymptomatic women varies with age. In younger and middle-age, WC ≥80 cm yielded high sensitivity and modest specificity for two or more risk factors, however, sensitivity for one or more risk factor was less than optimal. WC ≥88 cm showed better validity than WC ≥80 cm in elderly. Our results support age-specific screening cut-off points for women. PMID:25294689

  12. Age-related differences in recommended anthropometric cut-off point validity to identify cardiovascular risk factors in ostensibly healthy women.

    PubMed

    Subramoney, Sreevidya; Björkelund, Cecilia; Guo, Xinxin; Skoog, Ingmar; Bosaeus, Ingvar; Lissner, Lauren

    2014-12-01

    To investigate validity of widely recommended anthropometric and total fat percentage cut-off points in screening for cardiovascular risk factors in women of different ages. A population-based sample of 1002 Swedish women aged 38, 50, 75 (younger, middle-aged and elderly, respectively) underwent anthropometry, health examinations and blood tests. Total fat was estimated (bioimpedance) in 670 women. Sensitivity, specificity of body mass index (BMI; ≥25 and ≥30), waist circumference (WC; ≥80 cm and ≥88 cm) and total fat percentage (TF; ≥35%) cut-off points for cardiovascular risk factors (dyslipidaemias, hypertension and hyperglycaemia) were calculated for each age. Cut-off points yielding high sensitivity together with modest specificity were considered valid. Women reporting hospital admission for cardiovascular disease were excluded. The sensitivity of WC ≥80 cm for one or more risk factors was ~60% in younger and middle-aged women, and 80% in elderly women. The specificity of WC ≥80 cm for one or more risk factors was 69%, 57% and 40% at the three ages (p < .05 for age trends). WC ≥80 cm yielded ~80% sensitivity for two or more risk factors across all ages. However, specificity decreased with increasing age (p < .0001), being 33% in elderly. WC ≥88 cm provided better specificity in elderly women. BMI and TF % cut-off points were not better than WC. Validity of recommended anthropometric cut-off points in screening asymptomatic women varies with age. In younger and middle-age, WC ≥80 cm yielded high sensitivity and modest specificity for two or more risk factors, however, sensitivity for one or more risk factor was less than optimal. WC ≥88 cm showed better validity than WC ≥80 cm in elderly. Our results support age-specific screening cut-off points for women. © 2014 the Nordic Societies of Public Health.

  13. Diagnostic performance of HbA1c for diabetes in Arab vs. European populations: a systematic review and meta-analysis.

    PubMed

    Bertran, E A; Berlie, H D; Taylor, A; Divine, G; Jaber, L A

    2017-02-01

    To examine differences in the performance of HbA 1c for diagnosing diabetes in Arabs compared with Europeans. The PubMed, Embase and Cochrane library databases were searched for records published between 1998 and 2015. Estimates of sensitivity, specificity and log diagnostic odds ratios for an HbA 1c cut-point of 48 mmol/mol (6.5%) were compared between Arabs and Europeans, using a bivariate linear mixed-model approach. For studies reporting multiple cut-points, population-specific summary receiver operating characteristic (SROC) curves were constructed. In addition, sensitivity, specificity and Youden Index were estimated for strata defined by HbA 1c cut-point and population type. Database searches yielded 1912 unique records; 618 full-text articles were reviewed. Fourteen studies met the inclusion criteria; hand-searching yielded three additional eligible studies. Three Arab (N = 2880) and 16 European populations (N = 49 127) were included in the analysis. Summary sensitivity and specificity for a HbA 1c cut-point of 48 mmol/mol (6.5%) in both populations were 42% (33-51%), and 97% (95-98%). There was no difference in area under SROC curves between Arab and European populations (0.844 vs. 0.847; P = 0.867), suggesting no difference in HbA 1c diagnostic accuracy between populations. Multiple cut-point summary estimates stratified by population suggest that Arabs have lower sensitivity and higher specificity at a HbA 1c cut-point of 44 mmol/mol (6.2%) compared with European populations. Estimates also suggest similar test performance at cut-points of 44 mmol/mol (6.2%) and 48 mmol/mol (6.5%) for Arabs. Given the low sensitivity of HbA 1c in the high-risk Arab American population, we recommend a combination of glucose-based and HbA 1c testing to ensure an accurate and timely diagnosis of diabetes. © 2016 Diabetes UK.

  14. Cut-off Points for Muscle Mass - Not Grip Strength or Gait Speed - Determine Variations in Sarcopenia Prevalence.

    PubMed

    Masanés, F; Rojano I Luque, X; Salvà, A; Serra-Rexach, J A; Artaza, I; Formiga, F; Cuesta, F; López Soto, A; Ruiz, D; Cruz-Jentoft, A J

    2017-01-01

    The European Working Group on Sarcopenia in Older People (EWGSOP) has proposed different methods and cut-off points for the three parameters that define sarcopenia: muscle mass, muscle strength and physical performance. Although this facilitates clinical practice, it limits comparability between studies and leads to wide differences in published prevalence rates. The aim of this study was to assess how changes in cut-off points for muscle mass, gait speed and grip strength affected sarcopenia prevalence according to EWGSOP criteria. Cross-sectional analysis of elderly individuals recruited from outpatient clinics (n=298) and nursing homes (n=276). We measured muscle mass, grip strength and gait speed and assessed how changes in cut-off points changed sarcopenia prevalence in both populations. An increase from 5.45 kg/m2 to 6.68 kg/m2 in the muscle mass index for female outpatients and nursing-home residents increased sarcopenia prevalence from 4% to 23% and from 9% to 47%, respectively; for men, for an increase from 7.25 kg/m2 to 8.87 kg/m2, the corresponding increases were from 1% to 22% and from 6% to 41%, respectively. Changes in gait speed and grip strength had a limited impact on sarcopenia prevalence. The cut-off points used for muscle mass affect the reported prevalence rates for sarcopenia and, in turn, affect comparability between studies. The main factors influencing the magnitude of the change are muscle mass index distribution in the population and the absolute value of the cut-off points: the same difference between two references (e.g., 7.5 kg/m2 to 7.75 kg/m2 or 7.75 kg/m2 to 8 kg/m2) may produce different changes in prevalence. Changes in cut-off points for gait speed and grip strength had a limited impact on sarcopenia prevalence and on study comparability.

  15. Investigating Clinically and Scientifically Useful Cut Points on the Compulsive Sexual Behavior Inventory

    PubMed Central

    Miner, Michael H.; Raymond, Nancy; Coleman, Eli; Romine, Rebecca Swinburne

    2017-01-01

    Introduction One of the major obstacles to conducting epidemiological research and determining the incidence and prevalence of compulsive sexual behavior has been the lack of relevant, empirically derived cut points on the various instruments that have been used to measure the concept. Aim To further develop the Compulsive Sexual Behavior Inventory (CSBI) through exploring predictive validity and developing an empirically determined and clinically useful cut point for defining CSB. Methods A sample of 242 men who have sex with men was recruited from various sites in a moderate-size Midwestern city. Participants were assigned to a CSB group or a control group using an interview for the diagnosis that was patterned after the Structured Clinical Interview for the Diagnostic and Statistical Manual for Mental Disorders, Fourth Edition. The 22-item CSBI was administered as part of a larger battery of self-report inventories. Main Outcome Measures ROC analyses were used to compute AUC measures to ascertain predictive validity of the total scale, the control subscale and the violence subscale. Cut-points were determined through consensus of experts balancing sensitivity and specificity as determined by ROC curves. Results Analyses indicated that the 22-item CSBI was a good predictor of group membership, as was the 13-item control subscale. The Violence subscale added little to the predictive accuracy of the instrument and thus, it likely measures something other than CSB. Two relevant cut points were found, one that minimized false negatives and another, more conservative cut-point that minimized false positives. Conclusion The CSBI as currently configured measures two different constructions and only the Control subscale is helpful in diagnosing CSB. We have, therefore, decided to eliminate the Violence subscale and move forward with a 13-item scale that we have named the CSBI-13. Two cut points were developed from this revised scale, one which is useful as a clinical screening and the other, more conservative measure useful for etiological and epidemiological research. PMID:28499521

  16. Influence of cutting parameters on the depth of subsurface deformed layer in nano-cutting process of single crystal copper.

    PubMed

    Wang, Quanlong; Bai, Qingshun; Chen, Jiaxuan; Su, Hao; Wang, Zhiguo; Xie, Wenkun

    2015-12-01

    Large-scale molecular dynamics simulation is performed to study the nano-cutting process of single crystal copper realized by single-point diamond cutting tool in this paper. The centro-symmetry parameter is adopted to characterize the subsurface deformed layers and the distribution and evolution of the subsurface defect structures. Three-dimensional visualization and measurement technology are used to measure the depth of the subsurface deformed layers. The influence of cutting speed, cutting depth, cutting direction, and crystallographic orientation on the depth of subsurface deformed layers is systematically investigated. The results show that a lot of defect structures are formed in the subsurface of workpiece during nano-cutting process, for instance, stair-rod dislocations, stacking fault tetrahedron, atomic clusters, vacancy defects, point defects. In the process of nano-cutting, the depth of subsurface deformed layers increases with the cutting distance at the beginning, then decreases at stable cutting process, and basically remains unchanged when the cutting distance reaches up to 24 nm. The depth of subsurface deformed layers decreases with the increase in cutting speed between 50 and 300 m/s. The depth of subsurface deformed layer increases with cutting depth, proportionally, and basically remains unchanged when the cutting depth reaches over 6 nm.

  17. Use of a wireless, inertial sensor-based system to objectively evaluate flexion tests in the horse.

    PubMed

    Marshall, J F; Lund, D G; Voute, L C

    2012-12-01

    A wireless, inertial sensor-based system has previously been validated for evaluation of equine lameness. However, threshold values have not been determined for the assessment of responses to flexion tests. The aim of this investigation was to evaluate a sensor-based system for objective assessment of the response to flexion. Healthy adult horses (n = 17) in work were recruited prospectively. Horses were instrumented with sensors on the head (accelerometer), pelvis (accelerometer) and right forelimb (gyroscope), before trotting in a straight line (minimum 25 strides) for 2 consecutive trials. Sensors measured 1) vertical pelvic movement asymmetry (PMA) for both right and left hindlimb strides and 2) average difference in maximum and minimum pelvic height (PDMax and PDMin) between right and left hindlimb strides in millimetres. A hindlimb was randomly selected for proximal flexion (60 s), after which the horse trotted a minimum of 10 strides. Response to flexion was blindly assessed as negative or positive by an experienced observer. Changes in PMA, PDMax and PDMin between baseline and flexion examinations were calculated for each test. Statistical analysis consisted of a Pearson's product moment test and linear regression on baseline trials, Mann-Whitney rank sum test for effect of flexion and receiver operator curve (ROC) analysis of test parameters. There was a strong correlation between trials for PMA, PDMin and PDMax measurements (P < 0.001). A positive flexion test resulted in a significant increase in PMA (P = 0.021) and PDMax (P = 0.05) only. Receiver-operator curve analysis established cut-off values for change in PMA and PDMax of 0.068 and 4.47 mm, respectively (sensitivity = 0.71, specificity = 0.65) to indicate a positive response to flexion. A positive response to flexion resulted in significant changes to objective measurements of pelvic symmetry. Findings support the use of inertial sensor systems to objectively assess response to flexion tests. Further investigation is warranted to establish cut-off values for objective assessment of other diagnostic procedures.

  18. Improved Signal Processing Technique Leads to More Robust Self Diagnostic Accelerometer System

    NASA Technical Reports Server (NTRS)

    Tokars, Roger; Lekki, John; Jaros, Dave; Riggs, Terrence; Evans, Kenneth P.

    2010-01-01

    The self diagnostic accelerometer (SDA) is a sensor system designed to actively monitor the health of an accelerometer. In this case an accelerometer is considered healthy if it can be determined that it is operating correctly and its measurements may be relied upon. The SDA system accomplishes this by actively monitoring the accelerometer for a variety of failure conditions including accelerometer structural damage, an electrical open circuit, and most importantly accelerometer detachment. In recent testing of the SDA system in emulated engine operating conditions it has been found that a more robust signal processing technique was necessary. An improved accelerometer diagnostic technique and test results of the SDA system utilizing this technique are presented here. Furthermore, the real time, autonomous capability of the SDA system to concurrently compensate for effects from real operating conditions such as temperature changes and mechanical noise, while monitoring the condition of the accelerometer health and attachment, will be demonstrated.

  19. Categorization of low cardiorespiratory fitness using obesity indices in non-smoking Singaporean women.

    PubMed

    Pua, Yong-Hao; Lim, Cheng-Kuan; Ang, Adele

    2006-11-01

    To revisit cut-off values of BMI, waist circumference (WC), and waist-to-stature ratio (WSR) based on their association with cardiorespiratory fitness (CRF). The derived cut-off points were compared with current values (BMI, 25.0 kg/m(2); WC, 80 cm) as recommended by the World Health Organization. Anthropometric indices were measured in a cross sectional study of 358 Singaporean female employees of a large tertiary hospital (63% Singaporean Chinese, 28% Malays, and 9% Indians). CRF was determined by the 1-mile walk test. Receiver operating characteristic curves were constructed to determine cut-off points. The cut-off points for BMI, WC, and WSR were 23.6 kg/m(2), 75.3 cm, and 0.48, respectively. The areas under the curve of BMI, WC, and WSR were 0.68, 0.74, and 0.74, respectively. For a given BMI, women with low CRF had higher WSR compared with women with high CRF. These findings provide convergent evidence that the cut-off points for Singaporean women were lower than the World Health Organization's criteria but were in good agreement with those reported for Asians.

  20. Identifying cut points for biomarker defined subset effects in clinical trials with survival endpoints.

    PubMed

    He, Pei

    2014-07-01

    The advancements in biotechnology and genetics lead to an increasing research interest in personalized medicine, where a patient's genetic profile or biological traits contribute to choosing the most effective treatment for the patient. The process starts with finding a specific biomarker among all possible candidates that can best predict the treatment effect. After a biomarker is chosen, identifying a cut point of the biomarker value that splits the patients into treatment effective and non-effective subgroups becomes an important scientific problem. Numerous methods have been proposed to validate the predictive marker and select the appropriate cut points either prospectively or retrospectively using clinical trial data. In trials with survival outcomes, the current practice applies an interaction testing procedure and chooses the cut point that minimizes the p-values for the tests. Such method assumes independence between the baseline hazard and biomarker value. In reality, however, this assumption is often violated, as the chosen biomarker might also be prognostic in addition to its predictive nature for treatment effect. In this paper we propose a block-wise estimation and a sequential testing approach to identify the cut point in biomarkers that can group the patients into subsets based on their distinct treatment outcomes without assuming independence between the biomarker and baseline hazard. Numerical results based on simulated survival data show that the proposed method could pinpoint accurately the cut points in biomarker values that separate the patient subpopulations into subgroups with distinctive treatment outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Changes in Physical Activity in the School, Afterschool, and Evening Periods during the Transition from Elementary to Middle School

    ERIC Educational Resources Information Center

    Lau, Erica Y.; Dowda, Marsha; McIver, Kerry L.; Pate, Russell R.

    2017-01-01

    Background: We examined longitudinal changes in children's physical activity during the school day, afterschool, and evening across fifth, sixth, and seventh grades. Methods: The analytical sample included children who had valid accelerometer data in fifth grade and at least one other time-point, and provided complete sociodemographic information…

  2. Sensitivity and specificity of waist circumference as a single screening tool for identification of overweight and obesity among Malaysian adults.

    PubMed

    Kee, C C; Jamaiyah, H; Geeta, A; Ali, Z Ahmad; Safiza, M N Noor; Suzana, S; Khor, G L; Rahmah, R; Jamalludin, A R; Sumarni, M G; Lim, K H; Faudzi, Y Ahmad; Amal, N M

    2011-12-01

    Generalised obesity and central obesity are risk factors for Type II diabetes mellitus and cardiovascular diseases. Waist circumference (WC) has been suggested as a single screening tool for identification of overweight or obese subjects in lieu of the body mass index (BMI) for weight management in public health program. Currently, the recommended waist circumference cut-off points of > or = 94cm for men and > or =80cm for women (waist action level 1) and > or = 102cm for men and > or = 88cm for women (waist action level 2) used for identification of overweight and obesity are based on studies in Caucasian populations. The objective of this study was to assess the sensitivity and specificity of the recommended waist action levels, and to determine optimal WC cut-off points for identification of overweight or obesity with central fat distribution based on BMI for Malaysian adults. Data from 32,773 subjects (14,982 men and 17,791 women) aged 18 and above who participated in the Third National Health Morbidity Survey in 2006 were analysed. Sensitivity and specificity of WC at waist action level 1 were 48.3% and 97.5% for men; and 84.2% and 80.6% for women when compared to the cut-off points based on BMI > or = 25kg/m2. At waist action level 2, sensitivity and specificity were 52.4% and 98.0% for men, and 79.2% and 85.4% for women when compared with the cut-off points based on BMI (> or = 30 kg/m2). Receiver operating characteristic analyses showed that the appropriatescreening cut-off points for WC to identify subjects with overweight (> or = 25kg/m2) was 86.0cm (sensitivity=83.6%, specificity=82.5%) for men, and 79.1cm (sensitivity=85.0%, specificity=79.5%) for women. Waist circumference cut-off points to identify obese subjects (BMI > or = 30 kg/m2) was 93.2cm (sensitivity=86.5%, specificity=85.7%) for men and 85.2cm (sensitivity=77.9%, specificity=78.0%) for women. Our findings demonstrated that the current recommended waist circumference cut-off points have low sensitivity for identification of overweight and obesity in men. We suggest that these newly identified cut-off points be considered.

  3. Ethnicity-specific obesity cut-points in the development of Type 2 diabetes – a prospective study including three ethnic groups in the United Kingdom

    PubMed Central

    Tillin, T; Sattar, N; Godsland, I F; Hughes, A D; Chaturvedi, N; Forouhi, N G

    2015-01-01

    Aims Conventional definitions of obesity, e.g. body mass index (BMI) ≥ 30 kg/m2 or waist circumference cut-points of 102 cm (men) and 88 cm (women), may underestimate metabolic risk in non-Europeans. We prospectively identified equivalent ethnicity-specific obesity cut-points for the estimation of diabetes risk in British South Asians, African-Caribbeans and Europeans. Methods We studied a population-based cohort from London, UK (1356 Europeans, 842 South Asians, 335 African-Caribbeans) who were aged 40–69 years at baseline (1988–1991), when they underwent anthropometry, fasting and post-load (75 g oral glucose tolerance test) blood tests. Incident Type 2 diabetes was identified from primary care records, participant recall and/or follow-up biochemistry. Ethnicity-specific obesity cut-points in association with diabetes incidence were estimated using negative binomial regression. Results Diabetes incidence rates (per 1000 person years) at a median follow-up of 19 years were 20.8 (95% CI: 18.4, 23.6) and 12.0 (8.3, 17.2) in South Asian men and women, 16.5 (12.7, 21.4) and 17.5 (13.0, 23.7) in African-Caribbean men and women, and 7.4 (6.3, 8.7), and 7.2 (5.3, 9.8) in European men and women. For incidence rates equivalent to those at a BMI of 30 kg/m2 in European men and women, age- and sex-adjusted cut-points were: South Asians, 25.2 (23.4, 26.6) kg/m2; and African-Caribbeans, 27.2 (25.2, 28.6) kg/m2. For South Asian and African-Caribbean men, respectively, waist circumference cut-points of 90.4 (85.0, 94.5) and 90.6 (85.0, 94.5) cm were equivalent to a value of 102 cm in European men. Waist circumference cut-points of 84.0 (74.0, 90.0) cm in South Asian women and 81.2 (71.4, 87.4) cm in African-Caribbean women were equivalent to a value of 88 cm in European women. Conclusions In prospective analyses, British South Asians and African-Caribbeans had equivalent diabetes incidence rates at substantially lower obesity levels than the conventional European cut-points. PMID:25186015

  4. Investigating Clinically and Scientifically Useful Cut Points on the Compulsive Sexual Behavior Inventory.

    PubMed

    Miner, Michael H; Raymond, Nancy; Coleman, Eli; Swinburne Romine, Rebecca

    2017-05-01

    One of the major obstacles to conducting epidemiologic research and determining the incidence and prevalence of compulsive sexual behavior (CSB) has been the lack of relevant empirically derived cut points on the various instruments that have been used to measure the concept. To further develop the Compulsive Sexual Behavior Inventory (CSBI) through exploring predictive validity and developing an empirically determined and clinically useful cut point for defining CSB. A sample of 242 men who have sex with men was recruited from various sites in a moderate-size Midwestern city. Participants were assigned to a CSB group or a control group using an interview for the diagnosis that was patterned after the Structured Clinical Interview for the Diagnostic and Statistical Manual for Mental Disorders, Fourth Edition. The 22-item CSBI was administered as part of a larger battery of self-report inventories. Receiver operating characteristic analyses were used to compute area-under-the-curve measurements to ascertain the predictive validity of the total scale, the control subscale, and the violence subscale. Cut points were determined through consensus of experts balancing sensitivity and specificity as determined by receiver operating characteristic curves. Analyses indicated that the 22-item CSBI was a good predictor of group membership, as was the 13-item control subscale. The violence subscale added little to the predictive accuracy of the instrument; thus, it likely measures something other than CSB. Two relevant cut points were found, one that minimized false negatives and another, more conservative cut point that minimized false positives. The CSBI as currently configured measures two different constructions and only the control subscale is helpful in diagnosing CSB. Therefore, we decided to eliminate the violence subscale and move forward with a 13-item scale that we have named the CSBI-13. Two cut points were developed from this revised scale, one that is useful as a clinical screening tool and the other, more conservative measurement that is useful for etiologic and epidemiologic research. Miner MH, Raymond N, Coleman E, Swinburne Romine R. Investigating Clinically and Scientifically Useful Cut Points on the Compulsive Sexual Behavior Inventory. J Sex Med 2017;14:715-720. Copyright © 2017 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  5. Foodservice yield and fabrication times for beef as influenced by purchasing options and merchandising styles.

    PubMed

    Weatherly, B H; Griffin, D B; Johnson, H K; Walter, J P; De La Zerda, M J; Tipton, N C; Savell, J W

    2001-12-01

    Selected beef subprimals were obtained from fabrication lines of three foodservice purveyors to assist in the development of a software support program for the beef foodservice industry. Subprimals were fabricated into bone-in or boneless foodservice ready-to-cook portion-sized cuts and associated components by professional meat cutters. Each subprimal was cut to generate mean foodservice cutting yields and labor requirements, which were calculated from observed weights (kilograms) and processing times (seconds). Once fabrication was completed, data were analyzed to determine means and standard errors of percentage yields and processing times for each subprimal. Subprimals cut to only one end point were evaluated for mean foodservice yields and processing times, but no comparisons were made within subprimal. However, those traditionally cut into various end points were additionally compared by cutting style. Subprimals cut by a single cutting style included rib, roast-ready; ribeye roll, lip-on, bone-in; brisket, deckle-off, boneless; top (inside) round; and bottom sirloin butt, flap, boneless. Subprimals cut into multiple end points or styles included ribeye, lip-on; top sirloin, cap; tenderloin butt, defatted; shortloin, short-cut; strip loin, boneless; top sirloin butt, boneless; and tenderloin, full, side muscle on, defatted. Mean yields of portion cuts, and mean fabrication times required to manufacture these cuts differed (P < 0.05) by cutting specification of the final product. In general, as the target portion size of fabricated steaks decreased, the mean number of steaks derived from any given subprimal cut increased, causing total foodservice yield to decrease and total processing time to increase. Therefore, an inverse relationship tended to exist between processing times and foodservice yields. With a method of accurately evaluating various beef purchase options, such as traditional commodity subprimals, closely trimmed subprimals, and pre-cut portion steaks in terms of yield and labor cost, foodservice operators will be better equipped to decide what option is more viable for their operation.

  6. Complications after LP related to needle type: pencil-point versus Quincke.

    PubMed

    Aamodt, A; Vedeler, C

    2001-06-01

    We studied the incidence of complications after diagnostic lumbar puncture (LP) related to needle type. A 5 months' observational study of routine diagnostic LP in 83 patients was conducted. Significantly more headache was observed after LP using thicker cutting needles (20G Quincke) compared with thinner cutting or non-cutting needles (22G Quincke or pencil-point). No significant difference in complications after LP was found between the 22G Quincke and pencil-point needles. The size of the needle and not the needle shape seems to be the main determinant for post-dural puncture headache (PDPH).

  7. Association Between Aerobic Fitness And High Blood Pressure in Adolescents in Brazil: Evidence for Criterion-Referenced Cut-Points.

    PubMed

    Silva, Diego Augusto; Tremblay, Mark; Pelegrini, Andreia; Dos Santos Silva, Roberto Jeronimo; Cabral de Oliveira, Antonio Cesar; Petroski, Edio Luiz

    2016-05-01

    Criterion-referenced cut-points for health-related fitness measures are lacking. This study aimed to determine the associations between aerobic fitness and high blood pressure levels (HBP) to determine the cut-points that best predict HBP among adolescents. This cross-sectional school-based study with sample of 875 adolescents aged 14-19 years was conducted in southern Brazil. Aerobic fitness was assessed using the modified Canadian Aerobic Fitness Test (mCAFT). Systolic and diastolic blood pressure were measured by the oscillometric method with a digital sphygmomanometer. Analyses controlled for sociodemographic variables, physical activity, body mass and biological maturation. Receiver Operating Characteristic (ROC) curves demonstrated that mCAFT measures could discriminate HBP in both sexes (female: AUC = 0.70; male: AUC = 0.63). The cut-points with the best discriminatory power for HBP were 32 mL·kg-1·min-1 for females and 40 mL·kg-1·min-1 for males. Females (OR = 8.4; 95% CI: 2.1, 33.7) and males (OR: 2.5; CI 95%: 1.2, 5.2) with low aerobic fitness levels were more likely to have HBP. mCAFT measures are inversely associated with BP and cut-points from ROC analyses have good discriminatory power for HBP.

  8. Olfactory Impairment in Chronic Rhinosinusitis Using Threshold, Discrimination, and Identification Scores

    PubMed Central

    Kohli, Preeti; Storck, Kristina A.; Schlosser, Rodney J.

    2016-01-01

    Differences in testing modalities and cut-points used to define olfactory dysfunction contribute to the wide variability in estimating the prevalence of olfactory dysfunction in chronic rhinosinusitis (CRS). The aim of this study is to report the prevalence of olfactory impairment using each component of the Sniffin’ Sticks test (threshold, discrimination, identification, and total score) with age-adjusted and ideal cut-points from normative populations. Patients meeting diagnostic criteria for CRS were enrolled from rhinology clinics at a tertiary academic center. Olfaction was assessed using the Sniffin’ Sticks test. The study population consisted of 110 patients. The prevalence of normosmia, hyposmia, and anosmia using total Sniffin’ Sticks score was 41.8%, 20.0%, and 38.2% using age-appropriate cut-points and 20.9%, 40.9%, and 38.2% using ideal cut-points. Olfactory impairment estimates for each dimension mirrored these findings, with threshold yielding the highest values. Threshold, discrimination, and identification were also found to be significantly correlated to each other (P < 0.001). In addition, computed tomography scores, asthma, allergy, and diabetes were found to be associated with olfactory dysfunction. In conclusion, the prevalence of olfactory dysfunction is dependent upon olfactory dimension and if age-adjusted cut-points are used. The method of olfactory testing should be chosen based upon specific clinical and research goals. PMID:27469973

  9. Brady's Geothermal Field - March 2016 Vibroseis SEG-Y Files and UTM Locations

    DOE Data Explorer

    Kurt Feigl

    2016-03-31

    PoroTomo March 2016 (Task 6.4) Updated vibroseis source locations with UTM locations. Supersedes gdr.openei.org/submissions/824. Updated vibroseis source location data for Stages 1-4, PoroTomo March 2016. This revision includes source point locations in UTM format (meters) for all four Stages of active source acquisition. Vibroseis sweep data were collected on a Signature Recorder unit (mfr Seismic Source) mounted in the vibroseis cab during the March 2016 PoroTomo active seismic survey Stages 1 to 4. Each sweep generated a GPS timed SEG-Y file with 4 input channels and a 20 second record length. Ch1 = pilot sweep, Ch2 = accelerometer output from the vibe's mass, Ch3 = accel output from the baseplase, and Ch4 = weighted sum of the accelerometer outputs. SEG-Y files are available via the links below.

  10. Miniaturized accelerometer made with ZnO nanowires

    NASA Astrophysics Data System (ADS)

    Song, Sangho; Kim, Jeong Woong; Kim, Hyun Chan; Yun, Youngmin; Kim, Jaehwan

    2017-04-01

    Miniaturized accelerometer is required in many applications, such as, robotics, haptic devices, gyroscopes, simulators and mobile devices. ZnO is an essential semiconductor material with wide direct band gap, thermal stability and piezoelectricity. Especially, well aligned ZnO nanowire is appropriate for piezoelectric applications since it can produce high electrical signal under mechanical load. To miniaturize accelerometer, an aligned ZnO nanowire is adopted to implement active piezoelectric layer of the accelerometer and copper is chosen for the head mass. To grow ZnO nanowire on the copper head mass, hydrothermal synthesis is conducted and the effect of ZnO nanowire length on the accelerometer performance is investigated. Refresh hydrothermal synthesis can increase the length of ZnO nanowire. The performance of the fabricated ZnO accelerometers is compared with a commercial accelerometer. Sensitivity and linearity of the fabricated accelerometers are investigated.

  11. Engineering evaluation of SSME dynamic data from engine tests and SSV flights

    NASA Technical Reports Server (NTRS)

    1986-01-01

    An engineering evaluation of dynamic data from SSME hot firing tests and SSV flights is summarized. The basic objective of the study is to provide analyses of vibration, strain and dynamic pressure measurements in support of MSFC performance and reliability improvement programs. A brief description of the SSME test program is given and a typical test evaluation cycle reviewed. Data banks generated to characterize SSME component dynamic characteristics are described and statistical analyses performed on these data base measurements are discussed. Analytical models applied to define the dynamic behavior of SSME components (such as turbopump bearing elements and the flight accelerometer safety cut-off system) are also summarized. Appendices are included to illustrate some typical tasks performed under this study.

  12. Definitions, measurement and prevalence of sedentary behaviour in adults with intellectual disabilities - A systematic review.

    PubMed

    Melville, Craig A; Oppewal, Alyt; Schäfer Elinder, Liselotte; Freiberger, Ellen; Guerra-Balic, Myriam; Hilgenkamp, Thessa I M; Einarsson, Ingi; Izquierdo-Gómez, Rocio H; Sansano-Nadal, Oriol; Rintala, Pauli; Cuesta-Vargas, Antonio; Giné-Garriga, Maria

    2017-04-01

    Supporting positive change in lifestyle behaviours is a priority in tackling the health inequalities experienced by adults with intellectual disabilities. In this systematic review, we examine the evidence on the definition, measurement and epidemiology of sedentary behaviour of adults with intellectual disabilities. A systematic literature search of PUBMED, EMBASE, MEDLINE and Google Scholar was performed to identify studies published from 1990 up to October 2015. Nineteen papers met the criteria for inclusion in the systematic review. Many researchers do not distinguish between insufficient physical activity and sedentary behaviour. None of the studies reported the reliability and validity of the methods used to measure sedentary behaviour. Sedentary time, assessed objectively, ranged from 522 to 643min/day: higher than in adults without intellectual disabilities. This first-ever review of sedentary behaviour and intellectual disabilities found that at present the evidence base is weak. Studies calibrating accelerometer data with criterion measures for sedentary behaviour are needed to determine specific cut-off points to measure sedentary behaviour in adults with intellectual disabilities. Researchers should also examine the reliability and validity of using proxy-report questionnaires to measure sedentary behaviour in this group. A better understanding of sedentary behaviour will inform the design of novel interventions to change lifestyle behaviours of adults with intellectual disabilities. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Intensity and duration of physical efforts in Physical Education classes.

    PubMed

    Kremer, Marina Marques; Reichert, Felipe Fossati; Hallal, Pedro Curi

    2012-04-01

    To evaluate the intensity and duration of physical efforts in Physical Education classes in primary and secondary school. School-based cross-sectional study carried out by means of the observation of 218 Physical Education classes, including a total of 272 students (each one of the students was evaluated three times). The study was carried out in the city of Pelotas (Southern Brazil), between August and December 2009. In order to evaluate the intensity of the efforts, accelerometers were used and the following cut-off points were adopted (in counts per minute): sedentary activities (0-100), light activities (101-2,000), moderate (2,001-4,999), vigorous (5,000-7,999), and very vigorous activities (>8000). The mean duration of the classes was 35.6 minutes (SD 6.0). The mean proportion of time spent in moderate to vigorous physical activity was 32.7% (SD 25.2). Boys (44.1%) were involved significantly more in moderate to vigorous physical activity as compared to girls (21.0%; p<0.01). Students who practice physical activities outside the classes participated more in moderate to vigorous physical activity in the Physical Education classes. Besides the fact that Physical Education classes have a short duration, students practice moderate to vigorous physical activity during one third of the class, with a poor significant contribution to students' level of physical activity.

  14. Fiber-matrix integrity, micromorphology and flexural strength of glass fiber posts: Evaluation of the impact of rotary instruments.

    PubMed

    Pereira, Gabriel Kalil Rocha; Lançanova, Mateus; Wandscher, Vinicius Felipe; Kaizer, Osvaldo Bazzan; Limberger, Inácio; Özcan, Mutlu; Valandro, Luiz Felipe

    2015-08-01

    Several rotary instruments have been daily employed on clinic to promote cut aiming to adjust the length of fiber posts to the radicular conduct, but there is no information on the literature about the effects of the different rotary instruments and its impact on the micromorphology of surface and mechanical properties of the glass fiber post. This study aimed the impact of rotary instruments upon fiber-matrix integrity, micromorphology and flexural-strength of glass-fiber posts (GFP). GFP (N=110) were divided into 5 groups: Ctrl: as-received posts, DBc: coarse diamond-bur, DBff: extra-fine diamond-bur, CB: carbide-bur, DD: diamond-disc. Cutting procedures were performed under abundant irrigation. Posts exposed to rotary instruments were then subjected to 2-point inclined loading test (compression 45°) (n=10/group) and 3-point flexural-strength test (n=10/group). Fiber-matrix integrity and micromorphology at the cut surface were analyzed using a SEM (n=2/group). Cutting procedures did not significantly affect the 2-point (51.7±4.3-56.7±5.1 MPa) (p=0.0233) and 3-point flexural-strength (671.5±35.3-709.1±33.1 MPa) (p=0.0968) of the posts (One-way ANOVA and Tukey׳s test). Fiber detachment was observed only at the end point of the cut at the margins of the post. Cut surfaces of the CB group were smoother than those of the other groups. After 3-point flexural strength test, fiber-matrix separation was evident at the tensile side of the post. Rotary instruments tested with simultaneous water-cooling did not affect the resistance of the tested fiber posts but caused disintegration of the fibers from the matrix at the end of the cut, located at the margins. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Deriving an optimal threshold of waist circumference for detecting cardiometabolic risk in sub-Saharan Africa.

    PubMed

    Ekoru, K; Murphy, G A V; Young, E H; Delisle, H; Jerome, C S; Assah, F; Longo-Mbenza, B; Nzambi, J P D; On'Kin, J B K; Buntix, F; Muyer, M C; Christensen, D L; Wesseh, C S; Sabir, A; Okafor, C; Gezawa, I D; Puepet, F; Enang, O; Raimi, T; Ohwovoriole, E; Oladapo, O O; Bovet, P; Mollentze, W; Unwin, N; Gray, W K; Walker, R; Agoudavi, K; Siziya, S; Chifamba, J; Njelekela, M; Fourie, C M; Kruger, S; Schutte, A E; Walsh, C; Gareta, D; Kamali, A; Seeley, J; Norris, S A; Crowther, N J; Pillay, D; Kaleebu, P; Motala, A A; Sandhu, M S

    2017-10-03

    Waist circumference (WC) thresholds derived from western populations continue to be used in sub-Saharan Africa (SSA) despite increasing evidence of ethnic variation in the association between adiposity and cardiometabolic disease and availability of data from African populations. We aimed to derive a SSA-specific optimal WC cut-point for identifying individuals at increased cardiometabolic risk. We used individual level cross-sectional data on 24 181 participants aged ⩾15 years from 17 studies conducted between 1990 and 2014 in eight countries in SSA. Receiver operating characteristic curves were used to derive optimal WC cut-points for detecting the presence of at least two components of metabolic syndrome (MS), excluding WC. The optimal WC cut-point was 81.2 cm (95% CI 78.5-83.8 cm) and 81.0 cm (95% CI 79.2-82.8 cm) for men and women, respectively, with comparable accuracy in men and women. Sensitivity was higher in women (64%, 95% CI 63-65) than in men (53%, 95% CI 51-55), and increased with the prevalence of obesity. Having WC above the derived cut-point was associated with a twofold probability of having at least two components of MS (age-adjusted odds ratio 2.6, 95% CI 2.4-2.9, for men and 2.2, 95% CI 2.0-2.3, for women). The optimal WC cut-point for identifying men at increased cardiometabolic risk is lower (⩾81.2 cm) than current guidelines (⩾94.0 cm) recommend, and similar to that in women in SSA. Prospective studies are needed to confirm these cut-points based on cardiometabolic outcomes.International Journal of Obesity advance online publication, 31 October 2017; doi:10.1038/ijo.2017.240.

  16. Measurement of asthma control according to global initiative for asthma guidelines: a comparison with the asthma control questionnaire

    PubMed Central

    2012-01-01

    Introduction Asthma Control Questionnaire (ACQ) is a validated tool to measure asthma control. Cut-off points that best discriminate “well-controlled” or “not well-controlled” asthma have been suggested from the analysis of a large randomized clinical trial but they may not be adequate for daily clinical practice. Aims To establish cut-off points of the ACQ that best discriminate the level of control according to Global Initiative for Asthma (GINA) 2006 guidelines in patients with asthma managed at Allergology and Pulmonology Departments as well as Primary Care Centers in Spain. Patients and methods An epidemiological descriptive study, with prospective data collection. Asthma control following GINA-2006 classification and 7-item ACQ was assessed. The study population was split in two parts: 2/3 for finding the cut-off points (development population) and 1/3 for validating the results (validation population). Results A total of 1,363 stable asthmatic patients were included (mean age 38 ± 14 years, 60.3% women; 69.1% non-smokers). Patient classification according to GINA-defined asthma control was: controlled 13.6%, partially controlled 34.2%, and uncontrolled 52.3%. The ACQ cut-off points that better agreed with GINA-defined asthma control categories were calculated using receiver operating curves (ROC). The analysis showed that ACQ < 0.5 was the optimal cut-off point for “controlled asthma” (sensitivity 74.1%, specificity 77.5%) and 1.00 for “uncontrolled asthma” (sensitivity 73%, specificity 88.2%). Kappa index between GINA categories and ACQ was 0.62 (p < 0.001). Conclusion The ACQ cut-off points associated with GINA-defined asthma control in a real-life setting were <0.5 for controlled asthma and ≥1 for uncontrolled asthma. PMID:22726416

  17. Reassessing the NTCTCS Staging Systems for Differentiated Thyroid Cancer, Including Age at Diagnosis

    PubMed Central

    McLeod, Donald S.A.; Jonklaas, Jacqueline; Brierley, James D.; Ain, Kenneth B.; Cooper, David S.; Fein, Henry G.; Haugen, Bryan R.; Ladenson, Paul W.; Magner, James; Ross, Douglas S.; Skarulis, Monica C.; Steward, David L.; Xing, Mingzhao; Litofsky, Danielle R.; Maxon, Harry R.

    2015-01-01

    Background: Thyroid cancer is unique for having age as a staging variable. Recently, the commonly used age cut-point of 45 years has been questioned. Objective: This study assessed alternate staging systems on the outcome of overall survival, and compared these with current National Thyroid Cancer Treatment Cooperative Study (NTCTCS) staging systems for papillary and follicular thyroid cancer. Methods: A total of 4721 patients with differentiated thyroid cancer were assessed. Five potential alternate staging systems were generated at age cut-points in five-year increments from 35 to 70 years, and tested for model discrimination (Harrell's C-statistic) and calibration (R2). The best five models for papillary and follicular cancer were further tested with bootstrap resampling and significance testing for discrimination. Results: The best five alternate papillary cancer systems had age cut-points of 45–50 years, with the highest scoring model using 50 years. No significant difference in C-statistic was found between the best alternate and current NTCTCS systems (p = 0.200). The best five alternate follicular cancer systems had age cut-points of 50–55 years, with the highest scoring model using 50 years. All five best alternate staging systems performed better compared with the current system (p = 0.003–0.035). There was no significant difference in discrimination between the best alternate system (cut-point age 50 years) and the best system of cut-point age 45 years (p = 0.197). Conclusions: No alternate papillary cancer systems assessed were significantly better than the current system. New alternate staging systems for follicular cancer appear to be better than the current NTCTCS system, although they require external validation. PMID:26203804

  18. [Validation of cut points of skeletal muscle mass index for identifying sarcopenia in Chilean older people].

    PubMed

    Lera, Lydia; Ángel, Bárbara; Sánchez, Hugo; Picrin, Yaisy; Hormazabal, María José; Quiero, Andrea; Albala, Cecilia

    2014-09-28

    To estimate and validate cut-off points of skeletal muscle mass index (SMI) in Chilean population, for using in an algorithm for a diagnosis of sarcopenia developed by European Working Group on Sarcopenia in Older People (EWGSOP). Secondary analysis of Cross-sectional data in 440 Chilean older subjects to estimate cut-off points of SMI determined by DEXA and predicted by an anthropometric equation. Afterward a cross-sectional validation in a sample of 164 older people was performed. Anthropometric measures, self-reported health status, physical performance tests and DEXA were carried out. Decreased muscle strength was defined as handgrip strength <15 kg in women and <27 kg in male. Cut-off points of SMI were defined as values under 20th percentile for DEXA measures and estimated through ROC curves for the anthropometric model. Biological validity of the algorithm was tested by contrasting the diagnosis with physical performance tests and functionality. Cut-off points of SMI obtained by DEXA were 7.19 kg/m² in men and 5.77 kg/m² in women and 7.45 kg/ m² and 5.88 kg/m², respectively for the predicted by the model. Sensibility and specificity of estimations vs DEXA measures were 80% and 92% in men and 77% and 89% in women. We obtained cut-off points of SMI for DEXA and for a prediction equation for older adults Chilean, with good sensibility and specificity for the measurement by DEXA. It will allow to apply the EWGSOP algorithm to the early diagnosis of sarcopenia and to develop programs for prevention, delay or reversion this syndrome. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  19. Are the QRS duration and ST depression cut-points from the Seattle criteria too conservative?

    PubMed

    Dunn, Tim; Abdelfattah, Ramy; Aggarwal, Sonya; Pickham, David; Hadley, David; Froelicher, Victor

    2015-01-01

    Screening athletes with ECGs is aimed at identifying "at-risk" individuals who may have a cardiac condition predisposing them to sudden cardiac death. The Seattle criteria highlight QRS duration greater than 140 ms and ST segment depression in two or more leads greater than 50 μV as two abnormal ECG patterns associated with sudden cardiac death. High school, college, and professional athletes underwent 12 lead ECGs as part of routine pre-participation physicals. Prevalence of prolonged QRS duration was measured using cut-points of 120, 125, 130, and 140 ms. ST segment depression was measured in all leads except leads III, aVR, and V1 with cut-points of 25 μV and 50 μV. Between June 2010 and November 2013, 1595 participants including 297 (167 male, mean age 16.2) high school athletes, 1016 (541 male, mean age 18.8) college athletes, and 282 (mean age 26.6) male professional athletes underwent screening with an ECG. Only 3 athletes (0.2%) had a QRS duration greater than 125 ms. ST segment depression in two or more leads greater than 50 μV was uncommon (0.8%), while the prevalence of ST segment depression in two or more leads increased to 4.5% with a cut-point of 25 μV. Changing the QRS duration cut-point to 125 ms would increase the sensitivity of the screening ECG, without a significant increase in false-positives. However, changing the ST segment depression cut-point to 25 μV would lead to a significant increase in false-positives and would therefore not be justified. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Categorical analysis of the impact of aerobic and resistance exercise training, alone and in combination, on cardiorespiratory fitness levels in patients with type 2 diabetes: results from the HART-D study.

    PubMed

    Johannsen, Neil M; Swift, Damon L; Lavie, Carl J; Earnest, Conrad P; Blair, Steven N; Church, Timothy S

    2013-10-01

    Low cardiorespiratory fitness (CRF) is an independent risk factor for cardiovascular disease (CVD), especially in individuals with type 2 diabetes. Age-predicted, sex-stratified, and maximal MET cut points have been developed to determine the risk of CVD events and mortality in low CRF categories. We examined the proportion of Health Benefits of Aerobic and Resistance Training in Individuals With Type 2 Diabetes (HART-D) participants above these cut points before and after 9 months of aerobic training (AT), resistance training (RT), or a combination of both (ATRT). Participants from the HART-D study (n=196) who were randomly assigned to exercise training (AT, RT, or ATRT) or to a nonexercise control group between April 2007 and August 2009 were used in this ancillary study. Cut points were previously established for age-predicted METs (>100% and >85%, mean and increased CVD risk, respectively), age- and sex-stratified METs (Aerobic Center Longitudinal Study), and clinically discernible METs (men>8.0, women>6.5). Baseline prevalence of participants above these cut points was similar for all intervention groups (P>0.50) and ranged from 11.9% (>100% age predicted) to 55.1% (>85% age predicted). Baseline prevalence and age-, sex-, and race/ethnic group-adjusted percentage of participants above each cut point increased significantly after AT and ATRT (P<0.05 for all). Structured exercise training, especially the AT component, was associated with a greater number of participants moving above established cut points indicative of low CRF. These results have public health and clinical implications for the growing number of patients with type 2 diabetes at high risk for CVD.

  1. Measurement of asthma control according to Global Initiative for Asthma guidelines: a comparison with the Asthma Control Questionnaire.

    PubMed

    Olaguibel, José María; Quirce, Santiago; Juliá, Berta; Fernández, Cristina; Fortuna, Ana María; Molina, Jesús; Plaza, Vicente

    2012-06-22

    Asthma Control Questionnaire (ACQ) is a validated tool to measure asthma control. Cut-off points that best discriminate "well-controlled" or "not well-controlled" asthma have been suggested from the analysis of a large randomized clinical trial but they may not be adequate for daily clinical practice. To establish cut-off points of the ACQ that best discriminate the level of control according to Global Initiative for Asthma (GINA) 2006 guidelines in patients with asthma managed at Allergology and Pulmonology Departments as well as Primary Care Centers in Spain. An epidemiological descriptive study, with prospective data collection. Asthma control following GINA-2006 classification and 7-item ACQ was assessed. The study population was split in two parts: 2/3 for finding the cut-off points (development population) and 1/3 for validating the results (validation population). A total of 1,363 stable asthmatic patients were included (mean age 38 ± 14 years, 60.3% women; 69.1% non-smokers). Patient classification according to GINA-defined asthma control was: controlled 13.6%, partially controlled 34.2%, and uncontrolled 52.3%. The ACQ cut-off points that better agreed with GINA-defined asthma control categories were calculated using receiver operating curves (ROC). The analysis showed that ACQ < 0.5 was the optimal cut-off point for "controlled asthma" (sensitivity 74.1%, specificity 77.5%) and 1.00 for "uncontrolled asthma" (sensitivity 73%, specificity 88.2%). Kappa index between GINA categories and ACQ was 0.62 (p < 0.001). The ACQ cut-off points associated with GINA-defined asthma control in a real-life setting were <0.5 for controlled asthma and ≥1 for uncontrolled asthma.

  2. Validation of the Alcohol Use Disorders Identification Test in university students: AUDIT and AUDIT-C.

    PubMed

    García Carretero, Miguel Ángel; Novalbos Ruiz, José Pedro; Martínez Delgado, José Manuel; O'Ferrall González, Cristina

    2016-03-02

    The aim of this study was to determine the psychometric properties of the Alcohol Use Disorders Identification Test (AUDIT and AUDIT-C) in order to detect problems related to the consumption of alcohol in the university population. The sample consisted of 1309 students.A Weekly Alcohol Consumption Diary was used as a gold standard; Cronbach's Alpha, the Kappa index, Spearman's correlation coefficient and exploratory factor analysis were applied for diagnostic reliability and validity, with ROC curves used to establish the different cut-off points. Binge Drinking (BD) episodes were found in 3.9% of men and 4.0% of women with otherwise low-risk drinking patterns. AUDIT identified 20.1% as high-risk drinkers and 6.4% as drinkers with physical-psychological problems and probable alcohol dependence.Cronbach's alpha of 0.75 demonstrates good internal consistency. The best cut-off points for high-risk drinking students were 8 for males and 6 for females. As for problem drinkers and probable ADS, 13 was the best cut-off point for both sexes. In relation to AUDIT-C, 5 and 4 were the best cut-off points for males and females with high-risk patterns, respectively. The criterion validity of AUDIT and AUDIT-C to detect binge drinking episodes was found to have a moderate K value. The results obtained show that AUDIT has good psychometric properties to detect early alcohol abuse disorders in university students; however, it is recommended that the cut-off point be reduced to 8 in men. AUDIT-C improves its predictive value by raising the cut-off point by one unit. Items 2 and 3 should be reviewed to increase its predictive value for BD.

  3. Influence of Fiber Orientation on Single-Point Cutting Fracture Behavior of Carbon-Fiber/Epoxy Prepreg Sheets.

    PubMed

    Wei, Yingying; An, Qinglong; Cai, Xiaojiang; Chen, Ming; Ming, Weiwei

    2015-10-02

    The purpose of this article is to investigate the influences of carbon fibers on the fracture mechanism of carbon fibers both in macroscopic view and microscopic view by using single-point flying cutting method. Cutting tools with three different materials were used in this research, namely, PCD (polycrystalline diamond) tool, CVD (chemical vapor deposition) diamond thin film coated carbide tool and uncoated carbide tool. The influence of fiber orientation on the cutting force and fracture topography were analyzed and conclusions were drawn that cutting forces are not affected by cutting speeds but significantly influenced by the fiber orientation. Cutting forces presented smaller values in the fiber orientation of 0/180° and 15/165° but the highest one in 30/150°. The fracture mechanism of carbon fibers was studied in different cutting conditions such as 0° orientation angle, 90° orientation angle, orientation angles along fiber direction, and orientation angles inverse to the fiber direction. In addition, a prediction model on the cutting defects of carbon fiber reinforced plastic was established based on acoustic emission (AE) signals.

  4. Influence of Fiber Orientation on Single-Point Cutting Fracture Behavior of Carbon-Fiber/Epoxy Prepreg Sheets

    PubMed Central

    Wei, Yingying; An, Qinglong; Cai, Xiaojiang; Chen, Ming; Ming, Weiwei

    2015-01-01

    The purpose of this article is to investigate the influences of carbon fibers on the fracture mechanism of carbon fibers both in macroscopic view and microscopic view by using single-point flying cutting method. Cutting tools with three different materials were used in this research, namely, PCD (polycrystalline diamond) tool, CVD (chemical vapor deposition) diamond thin film coated carbide tool and uncoated carbide tool. The influence of fiber orientation on the cutting force and fracture topography were analyzed and conclusions were drawn that cutting forces are not affected by cutting speeds but significantly influenced by the fiber orientation. Cutting forces presented smaller values in the fiber orientation of 0/180° and 15/165° but the highest one in 30/150°. The fracture mechanism of carbon fibers was studied in different cutting conditions such as 0° orientation angle, 90° orientation angle, orientation angles along fiber direction, and orientation angles inverse to the fiber direction. In addition, a prediction model on the cutting defects of carbon fiber reinforced plastic was established based on acoustic emission (AE) signals. PMID:28793597

  5. Performance improvement of miniaturized ZnO nanowire accelerometer fabricated by refresh hydrothermal synthesis

    PubMed Central

    Song, Sangho; Kim, Hyun Chan; Kim, Jung Woong; Kim, Debora

    2017-01-01

    Miniaturized accelerometers are necessary for evaluating the performance of small devices, such as haptics, robotics and simulators. In this study, we fabricated miniaturized accelerometers using well-aligned ZnO nanowires. The layer of ZnO nanowires is used for active piezoelectric layer of the accelerometer, and copper was chosen as a head mass. Seedless and refresh hydrothermal synthesis methods were conducted to grow ZnO nanowires on the copper substrate and the effect of ZnO nanowire length on the accelerometer performance was investigated. The refresh hydrothermal synthesis exhibits longer ZnO nanowires, 12 µm, than the seedless hydrothermal synthesis, 6 µm. Performance of the fabricated accelerometers was verified by comparing with a commercial accelerometer. The sensitivity of the fabricated accelerometer by the refresh hydrothermal synthesis is shown to be 37.7 pA g−1, which is about 30 times larger than the previous result. PMID:28989760

  6. A Model of Gravity Vector Measurement Noise for Estimating Accelerometer Bias in Gravity Disturbance Compensation.

    PubMed

    Tie, Junbo; Cao, Juliang; Chang, Lubing; Cai, Shaokun; Wu, Meiping; Lian, Junxiang

    2018-03-16

    Compensation of gravity disturbance can improve the precision of inertial navigation, but the effect of compensation will decrease due to the accelerometer bias, and estimation of the accelerometer bias is a crucial issue in gravity disturbance compensation. This paper first investigates the effect of accelerometer bias on gravity disturbance compensation, and the situation in which the accelerometer bias should be estimated is established. The accelerometer bias is estimated from the gravity vector measurement, and a model of measurement noise in gravity vector measurement is built. Based on this model, accelerometer bias is separated from the gravity vector measurement error by the method of least squares. Horizontal gravity disturbances are calculated through EGM2008 spherical harmonic model to build the simulation scene, and the simulation results indicate that precise estimations of the accelerometer bias can be obtained with the proposed method.

  7. A Model of Gravity Vector Measurement Noise for Estimating Accelerometer Bias in Gravity Disturbance Compensation

    PubMed Central

    Cao, Juliang; Cai, Shaokun; Wu, Meiping; Lian, Junxiang

    2018-01-01

    Compensation of gravity disturbance can improve the precision of inertial navigation, but the effect of compensation will decrease due to the accelerometer bias, and estimation of the accelerometer bias is a crucial issue in gravity disturbance compensation. This paper first investigates the effect of accelerometer bias on gravity disturbance compensation, and the situation in which the accelerometer bias should be estimated is established. The accelerometer bias is estimated from the gravity vector measurement, and a model of measurement noise in gravity vector measurement is built. Based on this model, accelerometer bias is separated from the gravity vector measurement error by the method of least squares. Horizontal gravity disturbances are calculated through EGM2008 spherical harmonic model to build the simulation scene, and the simulation results indicate that precise estimations of the accelerometer bias can be obtained with the proposed method. PMID:29547552

  8. Auto-Calibration and Fault Detection and Isolation of Skewed Redundant Accelerometers in Measurement While Drilling Systems.

    PubMed

    Seyed Moosavi, Seyed Mohsen; Moaveni, Bijan; Moshiri, Behzad; Arvan, Mohammad Reza

    2018-02-27

    The present study designed skewed redundant accelerometers for a Measurement While Drilling (MWD) tool and executed auto-calibration, fault diagnosis and isolation of accelerometers in this tool. The optimal structure includes four accelerometers was selected and designed precisely in accordance with the physical shape of the existing MWD tool. A new four-accelerometer structure was designed, implemented and installed on the current system, replacing the conventional orthogonal structure. Auto-calibration operation of skewed redundant accelerometers and all combinations of three accelerometers have been done. Consequently, biases, scale factors, and misalignment factors of accelerometers have been successfully estimated. By defecting the sensors in the new optimal skewed redundant structure, the fault was detected using the proposed FDI method and the faulty sensor was diagnosed and isolated. The results indicate that the system can continue to operate with at least three correct sensors.

  9. Auto-Calibration and Fault Detection and Isolation of Skewed Redundant Accelerometers in Measurement While Drilling Systems

    PubMed Central

    Seyed Moosavi, Seyed Mohsen; Moshiri, Behzad; Arvan, Mohammad Reza

    2018-01-01

    The present study designed skewed redundant accelerometers for a Measurement While Drilling (MWD) tool and executed auto-calibration, fault diagnosis and isolation of accelerometers in this tool. The optimal structure includes four accelerometers was selected and designed precisely in accordance with the physical shape of the existing MWD tool. A new four-accelerometer structure was designed, implemented and installed on the current system, replacing the conventional orthogonal structure. Auto-calibration operation of skewed redundant accelerometers and all combinations of three accelerometers have been done. Consequently, biases, scale factors, and misalignment factors of accelerometers have been successfully estimated. By defecting the sensors in the new optimal skewed redundant structure, the fault was detected using the proposed FDI method and the faulty sensor was diagnosed and isolated. The results indicate that the system can continue to operate with at least three correct sensors. PMID:29495434

  10. An ultra-precision tool nanoindentation instrument for replication of single point diamond tool cutting edges

    NASA Astrophysics Data System (ADS)

    Cai, Yindi; Chen, Yuan-Liu; Xu, Malu; Shimizu, Yuki; Ito, So; Matsukuma, Hiraku; Gao, Wei

    2018-05-01

    Precision replication of the diamond tool cutting edge is required for non-destructive tool metrology. This paper presents an ultra-precision tool nanoindentation instrument designed and constructed for replication of the cutting edge of a single point diamond tool onto a selected soft metal workpiece by precisely indenting the tool cutting edge into the workpiece surface. The instrument has the ability to control the indentation depth with a nanometric resolution, enabling the replication of tool cutting edges with high precision. The motion of the diamond tool along the indentation direction is controlled by the piezoelectric actuator of a fast tool servo (FTS). An integrated capacitive sensor of the FTS is employed to detect the displacement of the diamond tool. The soft metal workpiece is attached to an aluminum cantilever whose deflection is monitored by another capacitive sensor, referred to as an outside capacitive sensor. The indentation force and depth can be accurately evaluated from the diamond tool displacement, the cantilever deflection and the cantilever spring constant. Experiments were carried out by replicating the cutting edge of a single point diamond tool with a nose radius of 2.0 mm on a copper workpiece surface. The profile of the replicated tool cutting edge was measured using an atomic force microscope (AFM). The effectiveness of the instrument in precision replication of diamond tool cutting edges is well-verified by the experimental results.

  11. 3D sensing for machine guidance in meat cutting applications

    NASA Astrophysics Data System (ADS)

    Daley, Wayne; Britton, Doug; Usher, Colin; Diao, Mamadou; Ruffin, Kevin

    2005-11-01

    Most cutting and deboning operations in meat processing require accurate cuts be made to obtain maximum yield and ensure food safety. This is a significant concern for purveyors of deboned product. This task is made more difficult by the variability that is present in most natural products. The specific application of interest in this paper is the production of deboned poultry breast. This is typically obtained from a cut of the broiler called a 'front half' that includes the breast and the wings. The deboning operation typically consists of a cut that starts at the shoulder joint and then continues along the scapula. Attentive humans with training do a very good job of making this cut. The breast meat is then removed by pulling on the wings. Inaccurate cuts lead to poor yield (amount of boneless meat obtained relative to the weight of the whole carcass) and increase the probability that bone fragments might end up in the product. As equipment designers seek to automate the deboning operation, the cutting task has been a significant obstacle to developing automation that maximizes yield without generating unacceptable levels of bone fragments. The current solution is to sort the bone-in product into different weight ranges and then to adjust the deboning machines to the average of these weight ranges. We propose an approach for obtaining key cut points by extrapolation from external reference points based on the anatomy of the bird. We show that this approach can be implemented using a stereo imaging system, and the accuracy in locating the cut points of interest is significantly improved. This should result in more accurate cuts and with this concomitantly improved yield while reducing the incidence of bones. We also believe the approach could be extended to the processing of other species.

  12. Is the present cut-point to define type 2 diabetes appropriate in Latin-Americans?

    PubMed Central

    López-Jaramillo, Patricio; Velandia-Carrillo, Carlos; Gómez-Arbeláez, Diego; Aldana-Campos, Martin

    2014-01-01

    The diagnosis of diabetes mellitus type 2 (DM2) is based either on increased plasma glucose or Glycated hemoglobin levels. Since these measures are the only means for diagnosis of DM2, they must be well adapted to each population according to their metabolic characteristics, given that these may vary in each population. The World Health Organization (WHO) determined the cut-points of plasma glucose levels for the diagnosis of DM2 by associating hyperglycemia with the risk of a specific microvascular complication-retinopathy. Cardiovascular diseases are however the principal causes of mortality in patients with DM2 and we reported that in the Colombo-Ecuadorian population impaired fasting glucose and impaired glucose tolerance are both risk markers for myocardial infarction. We propose that the current cut-points accepted by the WHO need to be revaluated in populations such as Latin America and that there should be lower cut points for glycaemia in this population, to reduce the prevalence of cardiovascular complications associated with DM2. PMID:25512777

  13. Establishing a standard definition for child overweight and obesity worldwide: international survey

    PubMed Central

    Cole, Tim J; Bellizzi, Mary C; Flegal, Katherine M; Dietz, William H

    2000-01-01

    Objective To develop an internationally acceptable definition of child overweight and obesity, specifying the measurement, the reference population, and the age and sex specific cut off points. Design International survey of six large nationally representative cross sectional growth studies. Setting Brazil, Great Britain, Hong Kong, the Netherlands, Singapore, and the United States. Subjects 97 876 males and 94 851 females from birth to 25 years of age. Main outcome measure Body mass index (weight/height2). Results For each of the surveys, centile curves were drawn that at age 18 years passed through the widely used cut off points of 25 and 30 kg/m2 for adult overweight and obesity. The resulting curves were averaged to provide age and sex specific cut off points from 2-18 years. Conclusions The proposed cut off points, which are less arbitrary and more internationally based than current alternatives, should help to provide internationally comparable prevalence rates of overweight and obesity in children. PMID:10797032

  14. Digital controller design: Continuous and discrete describing function analysis of the IPS system

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The dynamic equations and the mathematical model of the continuous-data IPS control system are developed. The IPS model considered included one flexible body mode and was hardmounted to the Orbiter/Pallet. The model contains equations describing a torque feed-forward loop (using accelerometers as inputs) which will aid in reducing the pointing errors caused by Orbiter disturbances.

  15. Method and apparatus for automatically tracking a workpiece surface. [Patents

    DOEpatents

    Not Available

    1981-02-03

    Laser cutting concepts and apparatus have been developed for cutting the shroud of the core fuel subassemblies. However, much care must be taken in the accuracy of the cutting since the fuel rods within the shroud often become warped and are forced into direct contact with the shroud in random regions. Thus, in order to cut the nuclear fuel rod shroud accurately so as not to puncture the cladding of the fuel rods, and to insure optimal cutting efficiency and performance, the focal point of beam need be maintained accurately at the workpiece surface. It becomes necessary to detect deviations in the level of the workpiece surface accurately in connection with the cutting process. Therefore, a method and apparatus for tracking the surface of a workpiece being cut by a laser beam coming from a focus head assembly is disclosed which includes two collimated laser beams directed onto the work-piece surface at spaced points by beam directing optics in generally parallel planes of incidence. A shift in spacing between the two points is detected by means of a video camera system and processed by a computer to yield a workpiece surface displacement signal which is input to a motor which raises or lowers the beam focus head accordingly.

  16. A Subnano-g Electrostatic Force-Rebalanced Flexure Accelerometer for Gravity Gradient Instruments.

    PubMed

    Yan, Shitao; Xie, Yafei; Zhang, Mengqi; Deng, Zhongguang; Tu, Liangcheng

    2017-11-18

    A subnano-g electrostatic force-rebalanced flexure accelerometer is designed for the rotating accelerometer gravity gradient instrument. This accelerometer has a large proof mass, which is supported inversely by two pairs of parallel leaf springs and is centered between two fixed capacitor plates. This novel design enables the proof mass to move exactly along the sensitive direction and exhibits a high rejection ratio at its cross-axis directions. Benefiting from large proof mass, high vacuum packaging, and air-tight sealing, the thermal Brownian noise of the accelerometer is lowered down to less than 0.2 ng / Hz with a quality factor of 15 and a natural resonant frequency of about 7.4 Hz . The accelerometer's designed measurement range is about ±1 mg. Based on the correlation analysis between a commercial triaxial seismometer and our accelerometer, the demonstrated self-noise of our accelerometers is reduced to lower than 0.3 ng / Hz over the frequency ranging from 0.2 to 2 Hz, which meets the requirement of the rotating accelerometer gravity gradiometer.

  17. Design and implementation of a micromechanical silicon resonant accelerometer.

    PubMed

    Huang, Libin; Yang, Hui; Gao, Yang; Zhao, Liye; Liang, Jinxing

    2013-11-19

    The micromechanical silicon resonant accelerometer has attracted considerable attention in the research and development of high-precision MEMS accelerometers because of its output of quasi-digital signals, high sensitivity, high resolution, wide dynamic range, anti-interference capacity and good stability. Because of the mismatching thermal expansion coefficients of silicon and glass, the micromechanical silicon resonant accelerometer based on the Silicon on Glass (SOG) technique is deeply affected by the temperature during the fabrication, packaging and use processes. The thermal stress caused by temperature changes directly affects the frequency output of the accelerometer. Based on the working principle of the micromechanical resonant accelerometer, a special accelerometer structure that reduces the temperature influence on the accelerometer is designed. The accelerometer can greatly reduce the thermal stress caused by high temperatures in the process of fabrication and packaging. Currently, the closed-loop drive circuit is devised based on a phase-locked loop. The unloaded resonant frequencies of the prototype of the micromechanical silicon resonant accelerometer are approximately 31.4 kHz and 31.5 kHz. The scale factor is 66.24003 Hz/g. The scale factor stability is 14.886 ppm, the scale factor repeatability is 23 ppm, the bias stability is 23 μg, the bias repeatability is 170 μg, and the bias temperature coefficient is 0.0734 Hz/°C.

  18. The location of the tibial accelerometer does influence impact acceleration parameters during running.

    PubMed

    Lucas-Cuevas, Angel Gabriel; Encarnación-Martínez, Alberto; Camacho-García, Andrés; Llana-Belloch, Salvador; Pérez-Soriano, Pedro

    2017-09-01

    Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s -1 with three accelerometers attached with double-sided tape and tightened to the participants' tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made.

  19. Mechanical fault detection of electric motors by laser vibrometer and accelerometer measurements

    NASA Astrophysics Data System (ADS)

    Cristalli, C.; Paone, N.; Rodríguez, R. M.

    2006-08-01

    This paper presents a comparative study between accelerometer and laser vibrometer measurements aimed at on-line quality control carried out on the universal motors used in washing machines, which exhibit defects localised mainly in the bearings, including faults in the cage, in the rolling element and in the outer and inner ring. A set of no defective and defective motors were analysed by means of the acceleration signal provided by the accelerometer, and the displacement and velocity signals given by a single-point laser vibrometer. Advantages and disadvantages of both absolute and relative sensors and of contact and non-contact instrumentation are discussed taking into account the applicability to real on-line quality control measurements and bringing to light the related measurement problems due to the specific environmental conditions of assembly lines and sensor installation constraints. The performance of different signal-processing algorithms is discussed: RMS computation at steady-state proves effective for pass or fail diagnosis, while the amplitude of selected frequencies in the averaged spectra allows also for classification of a variety of special faults in bearings. Joint time-frequency analysis output data can be successfully used for pass or fail diagnosis during transients, thus achieving a remarkable reduction in testing time, which is important for on-line diagnostics.

  20. A cross-sectional study of the individual, social, and built environmental correlates of pedometer-based physical activity among elementary school children.

    PubMed

    McCormack, Gavin R; Giles-Corti, Billie; Timperio, Anna; Wood, Georgina; Villanueva, Karen

    2011-04-12

    Children who participate in regular physical activity obtain health benefits. Preliminary pedometer-based cut-points representing sufficient levels of physical activity among youth have been established; however limited evidence regarding correlates of achieving these cut-points exists. The purpose of this study was to identify correlates of pedometer-based cut-points among elementary school-aged children. A cross-section of children in grades 5-7 (10-12 years of age) were randomly selected from the most (n = 13) and least (n = 12) 'walkable' public elementary schools (Perth, Western Australia), stratified by socioeconomic status. Children (n = 1480; response rate = 56.6%) and parents (n = 1332; response rate = 88.8%) completed a survey, and steps were collected from children using pedometers. Pedometer data were categorized to reflect the sex-specific pedometer-based cut-points of ≥15000 steps/day for boys and ≥12000 steps/day for girls. Associations between socio-demographic characteristics, sedentary and active leisure-time behavior, independent mobility, active transportation and built environmental variables - collected from the child and parent surveys - and meeting pedometer-based cut-points were estimated (odds ratios: OR) using generalized estimating equations. Overall 927 children participated in all components of the study and provided complete data. On average, children took 11407 ± 3136 steps/day (boys: 12270 ± 3350 vs. girls: 10681 ± 2745 steps/day; p < 0.001) and 25.9% (boys: 19.1 vs. girls: 31.6%; p < 0.001) achieved the pedometer-based cut-points.After adjusting for all other variables and school clustering, meeting the pedometer-based cut-points was negatively associated (p < 0.05) with being male (OR = 0.42), parent self-reported number of different destinations in the neighborhood (OR 0.93), and a friend's (OR 0.62) or relative's (OR 0.44, boys only) house being at least a 10-minute walk from home. Achieving the pedometer-based cut-points was positively associated with participating in screen-time < 2 hours/day (OR 1.88), not being driven to school (OR 1.48), attending a school located in a high SES neighborhood (OR 1.33), the average number of steps among children within the respondent's grade (for each 500 step/day increase: OR 1.29), and living further than a 10-minute walk from a relative's house (OR 1.69, girls only). Comprehensive multi-level interventions that reduce screen-time, encourage active travel to/from school and foster a physically active classroom culture might encourage more physical activity among children.

  1. A cross-sectional study of the individual, social, and built environmental correlates of pedometer-based physical activity among elementary school children

    PubMed Central

    2011-01-01

    Background Children who participate in regular physical activity obtain health benefits. Preliminary pedometer-based cut-points representing sufficient levels of physical activity among youth have been established; however limited evidence regarding correlates of achieving these cut-points exists. The purpose of this study was to identify correlates of pedometer-based cut-points among elementary school-aged children. Method A cross-section of children in grades 5-7 (10-12 years of age) were randomly selected from the most (n = 13) and least (n = 12) 'walkable' public elementary schools (Perth, Western Australia), stratified by socioeconomic status. Children (n = 1480; response rate = 56.6%) and parents (n = 1332; response rate = 88.8%) completed a survey, and steps were collected from children using pedometers. Pedometer data were categorized to reflect the sex-specific pedometer-based cut-points of ≥15000 steps/day for boys and ≥12000 steps/day for girls. Associations between socio-demographic characteristics, sedentary and active leisure-time behavior, independent mobility, active transportation and built environmental variables - collected from the child and parent surveys - and meeting pedometer-based cut-points were estimated (odds ratios: OR) using generalized estimating equations. Results Overall 927 children participated in all components of the study and provided complete data. On average, children took 11407 ± 3136 steps/day (boys: 12270 ± 3350 vs. girls: 10681 ± 2745 steps/day; p < 0.001) and 25.9% (boys: 19.1 vs. girls: 31.6%; p < 0.001) achieved the pedometer-based cut-points. After adjusting for all other variables and school clustering, meeting the pedometer-based cut-points was negatively associated (p < 0.05) with being male (OR = 0.42), parent self-reported number of different destinations in the neighborhood (OR 0.93), and a friend's (OR 0.62) or relative's (OR 0.44, boys only) house being at least a 10-minute walk from home. Achieving the pedometer-based cut-points was positively associated with participating in screen-time < 2 hours/day (OR 1.88), not being driven to school (OR 1.48), attending a school located in a high SES neighborhood (OR 1.33), the average number of steps among children within the respondent's grade (for each 500 step/day increase: OR 1.29), and living further than a 10-minute walk from a relative's house (OR 1.69, girls only). Conclusions Comprehensive multi-level interventions that reduce screen-time, encourage active travel to/from school and foster a physically active classroom culture might encourage more physical activity among children. PMID:21486475

  2. A Novel Haptic Interactive Approach to Simulation of Surgery Cutting Based on Mesh and Meshless Models

    PubMed Central

    Liu, Peter X.; Lai, Pinhua; Xu, Shaoping; Zou, Yanni

    2018-01-01

    In the present work, the majority of implemented virtual surgery simulation systems have been based on either a mesh or meshless strategy with regard to soft tissue modelling. To take full advantage of the mesh and meshless models, a novel coupled soft tissue cutting model is proposed. Specifically, the reconstructed virtual soft tissue consists of two essential components. One is associated with surface mesh that is convenient for surface rendering and the other with internal meshless point elements that is used to calculate the force feedback during cutting. To combine two components in a seamless way, virtual points are introduced. During the simulation of cutting, the Bezier curve is used to characterize smooth and vivid incision on the surface mesh. At the same time, the deformation of internal soft tissue caused by cutting operation can be treated as displacements of the internal point elements. Furthermore, we discussed and proved the stability and convergence of the proposed approach theoretically. The real biomechanical tests verified the validity of the introduced model. And the simulation experiments show that the proposed approach offers high computational efficiency and good visual effect, enabling cutting of soft tissue with high stability. PMID:29850006

  3. Validation and Comparison of Accelerometers Worn on the Hip, Thigh, and Wrists for Measuring Physical Activity and Sedentary Behavior.

    PubMed

    Montoye, Alexander H K; Pivarnik, James M; Mudd, Lanay M; Biswas, Subir; Pfeiffer, Karin A

    2016-01-01

    Recent evidence suggests that physical activity (PA) and sedentary behavior (SB) exert independent effects on health. Therefore, measurement methods that can accurately assess both constructs are needed. To compare the accuracy of accelerometers placed on the hip, thigh, and wrists, coupled with machine learning models, for measurement of PA intensity category (SB, light-intensity PA [LPA], and moderate- to vigorous-intensity PA [MVPA]) and breaks in SB. Forty young adults (21 female; age 22.0 ± 4.2 years) participated in a 90-minute semi-structured protocol, performing 13 activities (three sedentary, 10 non-sedentary) for 3-10 minutes each. Participants chose activity order, duration, and intensity. Direct observation (DO) was used as a criterion measure of PA intensity category, and transitions from SB to a non-sedentary activity were breaks in SB. Participants wore four accelerometers (right hip, right thigh, and both wrists), and a machine learning model was created for each accelerometer to predict PA intensity category. Sensitivity and specificity for PA intensity category classification were calculated and compared across accelerometers using repeated measures analysis of variance, and the number of breaks in SB was compared using repeated measures analysis of variance. Sensitivity and specificity values for the thigh-worn accelerometer were higher than for wrist- or hip-worn accelerometers, > 99% for all PA intensity categories. Sensitivity and specificity for the hip-worn accelerometer were 87-95% and 93-97%. The left wrist-worn accelerometer had sensitivities and specificities of > 97% for SB and LPA and 91-95% for MVPA, whereas the right wrist-worn accelerometer had sensitivities and specificities of 93-99% for SB and LPA but 67-84% for MVPA. The thigh-worn accelerometer had high accuracy for breaks in SB; all other accelerometers overestimated breaks in SB. Coupled with machine learning modeling, the thigh-worn accelerometer should be considered when objectively assessing PA and SB.

  4. Compact Circuit Preprocesses Accelerometer Output

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1993-01-01

    Compact electronic circuit transfers dc power to, and preprocesses ac output of, accelerometer and associated preamplifier. Incorporated into accelerometer case during initial fabrication or retrofit onto commercial accelerometer. Made of commercial integrated circuits and other conventional components; made smaller by use of micrologic and surface-mount technology.

  5. Tool enables proper mating of accelerometer and cable connector

    NASA Technical Reports Server (NTRS)

    Steed, C. N.

    1966-01-01

    Tool supports accelerometer in axial alignment with an accelerometer cable connector and permits tightening of the accelerometer to the cable connector with a torque wrench. This is done without damaging the components or permitting them to work loose under sustained, high-level vibrations.

  6. Self-noise models of five commercial strong-motion accelerometers

    USGS Publications Warehouse

    Ringler, Adam; Evans, John R.; Hutt, Charles R.

    2015-01-01

    To better characterize the noise of a number of commonly deployed accelerometers in a standardized way, we conducted noise measurements on five different models of strong‐motion accelerometers. Our study was limited to traditional accelerometers (Fig. 1) and is in no way exhaustive.

  7. Quasi-Static Calibration Method of a High-g Accelerometer

    PubMed Central

    Wang, Yan; Fan, Jinbiao; Zu, Jing; Xu, Peng

    2017-01-01

    To solve the problem of resonance during quasi-static calibration of high-g accelerometers, we deduce the relationship between the minimum excitation pulse width and the resonant frequency of the calibrated accelerometer according to the second-order mathematical model of the accelerometer, and improve the quasi-static calibration theory. We establish a quasi-static calibration testing system, which uses a gas gun to generate high-g acceleration signals, and apply a laser interferometer to reproduce the impact acceleration. These signals are used to drive the calibrated accelerometer. By comparing the excitation acceleration signal and the output responses of the calibrated accelerometer to the excitation signals, the impact sensitivity of the calibrated accelerometer is obtained. As indicated by the calibration test results, this calibration system produces excitation acceleration signals with a pulse width of less than 1000 μs, and realize the quasi-static calibration of high-g accelerometers with a resonant frequency above 20 kHz when the calibration error was 3%. PMID:28230743

  8. 49 CFR 234.237 - Reverse switch cut-out circuit.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Reverse switch cut-out circuit. 234.237 Section....237 Reverse switch cut-out circuit. A switch, when equipped with a switch circuit controller connected... warning system can only be cut out when the switch point is within one-half inch of full reverse position. ...

  9. 49 CFR 234.237 - Reverse switch cut-out circuit.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Reverse switch cut-out circuit. 234.237 Section....237 Reverse switch cut-out circuit. A switch, when equipped with a switch circuit controller connected... warning system can only be cut out when the switch point is within one-half inch of full reverse position. ...

  10. 49 CFR 234.237 - Reverse switch cut-out circuit.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Reverse switch cut-out circuit. 234.237 Section....237 Reverse switch cut-out circuit. A switch, when equipped with a switch circuit controller connected... warning system can only be cut out when the switch point is within one-half inch of full reverse position. ...

  11. Structural health monitoring using wireless sensor networks

    NASA Astrophysics Data System (ADS)

    Sreevallabhan, K.; Nikhil Chand, B.; Ramasamy, Sudha

    2017-11-01

    Monitoring and analysing health of large structures like bridges, dams, buildings and heavy machinery is important for safety, economical, operational, making prior protective measures, and repair and maintenance point of view. In recent years there is growing demand for such larger structures which in turn make people focus more on safety. By using Microelectromechanical Systems (MEMS) Accelerometer we can perform Structural Health Monitoring by studying the dynamic response through measure of ambient vibrations and strong motion of such structures. By using Wireless Sensor Networks (WSN) we can embed these sensors in wireless networks which helps us to transmit data wirelessly thus we can measure the data wirelessly at any remote location. This in turn reduces heavy wiring which is a cost effective as well as time consuming process to lay those wires. In this paper we developed WSN based MEMS-accelerometer for Structural to test the results in the railway bridge near VIT University, Vellore campus.

  12. Lathe leveler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lovelady, III, Michael W.J.

    A lathe leveler for centering a cutting tool in relation to a cylindrical work piece includes a first leveling arm having a first contact point disposed adjacent a distal end of the first leveling arm, a second leveling arm having a second contact point disposed adjacent a distal end of the second leveling arm, a leveling gage, and a leveling plate having a cutting tool receiving surface positioned parallel to a horizontal axis of the leveling gage and on a same plane as a midpoint of the first contact point and the second contact point. The leveling arms and levelingmore » plate are dimensioned and configured such that the cutting tool receiving surface is centered in relation to the work piece when the first and second contact points are in contact with one of the inner surface and outer surface of the cylindrical work piece and the leveling gage is centered.« less

  13. New Matching Method for Accelerometers in Gravity Gradiometer

    PubMed Central

    Wei, Hongwei; Wu, Meiping; Cao, Juliang

    2017-01-01

    The gravity gradiometer is widely used in mineral prospecting, including in the exploration of mineral, oil and gas deposits. The mismatch of accelerometers adversely affects the measuring precision of rotating accelerometer-based gravity gradiometers. Several strategies have been investigated to address the imbalance of accelerometers in gradiometers. These strategies, however, complicate gradiometer structures because feedback loops and re-designed accelerometers are needed in these strategies. In this paper, we present a novel matching method, which is based on a new configuration of accelerometers in a gravity gradiometer. In the new configuration, an angle was introduced between the measurement direction of the accelerometer and the spin direction. With the introduced angle, accelerometers could measure the centrifugal acceleration generated by the rotating disc. Matching was realized by updating the scale factors of the accelerometers with the help of centrifugal acceleration. Further simulation computations showed that after adopting the new matching method, signal-to-noise ratio improved from −41 dB to 22 dB. Compared with other matching methods, our method is more flexible and costs less. The matching accuracy of this new method is similar to that of other methods. Our method provides a new idea for matching methods in gravity gradiometer measurement. PMID:28757584

  14. Vibration transmissibility on rifle shooter: A comparison between accelerometer and laser Doppler vibrometer data

    NASA Astrophysics Data System (ADS)

    Scalise, L.; Casacanditella, L.; Santolini, C.; Martarelli, M.; Tomasini, E. P.

    2014-05-01

    The transmission of mechanical vibrations from tools to human subjects is known to be potentially dangerous for the circulatory and neurological systems. It is also known that such damages are strictly depending on the intensity and the frequency range of the vibrational signals transferred to the different anatomical districts. In this paper, very high impulsive signals, generated during a shooting by a rifle, will be studied, being such signals characterised by a very high acceleration amplitude as well as high frequency range. In this paper, it will be presented an experimental setup aimed to collect experimental data relative to the transmission of the vibration signals from the rifle to the shoulder of subject during the shooting action. In particular the transmissibility of acceleration signals, as well as of the velocity signals, between the rifle stock and the subject's back shoulder will be measured using two piezoelectric accelerometers and a single point laser Doppler vibrometer (LDV). Tests have been carried out in a shooting lab where a professional shooter has conducted the experiments, using different experimental configurations: two different types of stocks and two kinds of bullets with different weights were considered. Two uniaxial accelerometers were fixed on the stock of the weapon and on the back of the shoulder of the shooter respectively. Vibration from the back shoulder was also measured by means of a LDV simultaneously. A comparison of the measured results will be presented and the pros and cons of the use of contact and non-contact transducers will be discussed taking into account the possible sources of the measurement uncertainty as unwanted sensor vibrations for the accelerometer.

  15. The Evaluation of Physical Stillness with Wearable Chest and Arm Accelerometer during Chan Ding Practice.

    PubMed

    Chang, Kang-Ming; Chun, Yu-Teng; Chen, Sih-Huei; Lu, Luo; Su, Hsiao-Ting Jannis; Liang, Hung-Meng; Santhosh, Jayasree; Ching, Congo Tak-Shing; Liu, Shing-Hong

    2016-07-20

    Chan Ding training is beneficial to health and emotional wellbeing. More and more people have taken up this practice over the past few years. A major training method of Chan Ding is to focus on the ten Mailuns, i.e., energy points, and to maintain physical stillness. In this article, wireless wearable accelerometers were used to detect physical stillness, and the created physical stillness index (PSI) was also shown. Ninety college students participated in this study. Primarily, accelerometers used on the arms and chest were examined. The results showed that the PSI values on the arms were higher than that of the chest, when participants moved their bodies in three different ways, left-right, anterior-posterior, and hand, movements with natural breathing. Then, they were divided into three groups to practice Chan Ding for approximately thirty minutes. Participants without any Chan Ding experience were in Group I. Participants with one year of Chan Ding experience were in Group II, and participants with over three year of experience were in Group III. The Chinese Happiness Inventory (CHI) was also conducted. Results showed that the PSI of the three groups measured during 20-30 min were 0.123 ± 0.155, 0.012 ± 0.013, and 0.001 ± 0.0003, respectively (p < 0.001 ***). The averaged CHI scores of the three groups were 10.13, 17.17, and 25.53, respectively (p < 0.001 ***). Correlation coefficients between PSI and CHI of the three groups were -0.440, -0.369, and -0.537, respectively (p < 0.01 **). PSI value and the wearable accelerometer that are presently available on the market could be used to evaluate the quality of the physical stillness of the participants during Chan Ding practice.

  16. The Evaluation of Physical Stillness with Wearable Chest and Arm Accelerometer during Chan Ding Practice

    PubMed Central

    Chang, Kang-Ming; Chun, Yu-Teng; Chen, Sih-Huei; Lu, Luo; Su, Hsiao-Ting Jannis; Liang, Hung-Meng; Santhosh, Jayasree; Ching, Congo Tak-Shing; Liu, Shing-Hong

    2016-01-01

    Chan Ding training is beneficial to health and emotional wellbeing. More and more people have taken up this practice over the past few years. A major training method of Chan Ding is to focus on the ten Mailuns, i.e., energy points, and to maintain physical stillness. In this article, wireless wearable accelerometers were used to detect physical stillness, and the created physical stillness index (PSI) was also shown. Ninety college students participated in this study. Primarily, accelerometers used on the arms and chest were examined. The results showed that the PSI values on the arms were higher than that of the chest, when participants moved their bodies in three different ways, left-right, anterior-posterior, and hand, movements with natural breathing. Then, they were divided into three groups to practice Chan Ding for approximately thirty minutes. Participants without any Chan Ding experience were in Group I. Participants with one year of Chan Ding experience were in Group II, and participants with over three year of experience were in Group III. The Chinese Happiness Inventory (CHI) was also conducted. Results showed that the PSI of the three groups measured during 20–30 min were 0.123 ± 0.155, 0.012 ± 0.013, and 0.001 ± 0.0003, respectively (p < 0.001 ***). The averaged CHI scores of the three groups were 10.13, 17.17, and 25.53, respectively (p < 0.001 ***). Correlation coefficients between PSI and CHI of the three groups were −0.440, −0.369, and −0.537, respectively (p < 0.01 **). PSI value and the wearable accelerometer that are presently available on the market could be used to evaluate the quality of the physical stillness of the participants during Chan Ding practice. PMID:27447641

  17. Launcher Dynamic Data Acquisition

    DTIC Science & Technology

    2012-07-31

    K PR Pressure PR Pressure PR Accelerometer PR Accelerometer PR Accelerometer PR Pressure PR Pressure IEPE Microphone IEPE ...transducers, displacement potentiometers, or Integrated Electronics Piezoelectric ( IEPE ) microphones and accelerometers. The characteristics of these...Engineering Units HCl hydrogen chloride HVAC heating ventilation and cooling Hz hertz IEC International Electrotechnical Commission IEPE

  18. Design and Implementation of a Micromechanical Silicon Resonant Accelerometer

    PubMed Central

    Huang, Libin; Yang, Hui; Gao, Yang; Zhao, Liye; Liang, Jinxing

    2013-01-01

    The micromechanical silicon resonant accelerometer has attracted considerable attention in the research and development of high-precision MEMS accelerometers because of its output of quasi-digital signals, high sensitivity, high resolution, wide dynamic range, anti-interference capacity and good stability. Because of the mismatching thermal expansion coefficients of silicon and glass, the micromechanical silicon resonant accelerometer based on the Silicon on Glass (SOG) technique is deeply affected by the temperature during the fabrication, packaging and use processes. The thermal stress caused by temperature changes directly affects the frequency output of the accelerometer. Based on the working principle of the micromechanical resonant accelerometer, a special accelerometer structure that reduces the temperature influence on the accelerometer is designed. The accelerometer can greatly reduce the thermal stress caused by high temperatures in the process of fabrication and packaging. Currently, the closed-loop drive circuit is devised based on a phase-locked loop. The unloaded resonant frequencies of the prototype of the micromechanical silicon resonant accelerometer are approximately 31.4 kHz and 31.5 kHz. The scale factor is 66.24003 Hz/g. The scale factor stability is 14.886 ppm, the scale factor repeatability is 23 ppm, the bias stability is 23 μg, the bias repeatability is 170 μg, and the bias temperature coefficient is 0.0734 Hz/°C. PMID:24256978

  19. POD improvements of GALILEO satellites through the measurement of their non-gravitational accelerations by means of an onboard accelerometer

    NASA Astrophysics Data System (ADS)

    Peron, Roberto; Lucchesi, David M.; Santoli, Francesco; Iafolla, Valerio; Fiorenza, Emiliano; Lefevre, Carlo; Lucente, Marco; Magnafico, Carmelo; Kalarus, Maciej; Zielinski, Janusz

    2016-04-01

    The Precise Orbit Determination (POD) of the satellites of the Global Navigation Satellite Systems (GNSS) represents the basic prerequisite in order to provide refined ephemerides for their orbit, aimed at providing a precise and accurate positioning on the Earth. An important factor that impacts negatively in the POD of these satellites is the limited modeling of the accelerations produced by the non-gravitational accelerations. These, indeed, are subtle and generally complex to model properly, especially in the case of a complex in shape spacecraft, with solar panels and antennae for microwave link and the mutual shadowing effects among the many surfaces involved. We have to notice that their modeling has an important impact in the determination of a number of geophysical parameters of interest, such as stations coordinates, Earth's geocenter and orientation parameters. In the case of GNSS satellites, the main NGP acceleration is the one produced by the direct solar radiation pressure, with non-negligible contributions due to Earth's albedo, thermal effects and power radiated by the antennae. The models developed so far for these perturbative effects have shown many limits, as pointed out in the literature. Currently, the models developed for the NGPs are mainly based on empirical blind models (with the goal of absorb unknowns quantities) and more recently with the use of wing-box models, that try to provide a finite-elements approach to the modeling. The European Space Agency (ESA) - in the context of the development of the GALILEO constellation, and especially in view of the next generation of GALILEO spacecraft - besides being interested in possible improvements of the NGPs models, is also envisaging the use of an onboard accelerometer to directly measure them in order to improve the POD of each spacecraft of the constellation. We have been involved in this study by means of a proposal to ESA denominated GALileo and ACcelerometry (GALAC) led by the Space Research Centre (SRC) of the Polish Academy of Sciences (PAS) of Warsaw. The GALAC main objective is to provide the characteristics and performance of an onboard accelerometer able to improve the POD with respect to the current best results obtained through the modeling of the NGPs. The starting point of our activities has been the ISA accelerometer developed for the ESA BepiColombo mission to Mercury. We will present our results of a preparatory work for GALAC concerning a first characterization of the main NGPs acting on the GALILEO spacecraft of second generation, including their (main) spectral content. Such results are used to preliminary fix the accelerometer measurement band, its sensitivity and physical characteristics in order to fit with the GALILEO spacecraft environment.

  20. Assessment of Differing Definitions of Accelerometer Nonwear Time

    ERIC Educational Resources Information Center

    Evenson, Kelly R.; Terry, James W., Jr.

    2009-01-01

    Measuring physical activity with objective tools, such as accelerometers, is becoming more common. Accelerometers measure acceleration multiple times within a given frequency and summarize this as a count over a pre-specified time period or epoch. The resultant count represents acceleration over the epoch length. Accelerometers eliminate biases…

  1. Ki67 levels as predictive and prognostic parameters in pretherapeutic breast cancer core biopsies: a translational investigation in the neoadjuvant GeparTrio trial.

    PubMed

    Denkert, C; Loibl, S; Müller, B M; Eidtmann, H; Schmitt, W D; Eiermann, W; Gerber, B; Tesch, H; Hilfrich, J; Huober, J; Fehm, T; Barinoff, J; Jackisch, C; Prinzler, J; Rüdiger, T; Erbstösser, E; Blohmer, J U; Budczies, J; Mehta, K M; von Minckwitz, G

    2013-11-01

    The proliferation marker Ki67 has been suggested as a promising cancer biomarker. As Ki67 needs an exact quantification, this marker is a prototype of a new generation of tissue-based biomarkers. In this study, we have systematically evaluated different cut points for Ki67 using three different clinical end points in a large neoadjuvant study cohort. We have evaluated pretherapeutic Ki67 levels by immunohistochemistry in 1166 breast cancer core biopsies from the neoadjuvant GeparTrio trial. We used the standardized cutoff-finder algorithm for three end points [response to neoadjuvant chemotherapy (pCR), disease-free (DFS) and overall-survival (OS)]. The analyses were stratified for hormone receptor (HR) and HER2 status by molecular subtype radar diagrams (MSRDs). A wide range of Ki67 cut points between 3%-94% (for pCR), 6%-46% (for DFS) and 4%-58% (for OS) were significant. The three groups of Ki67 ≤ 15% versus 15.1%-35% versus >35% had pCR-rates of 4.2%, 12.8%, and 29.0% (P < 0.0005), this effect was also present in six of eight molecular subtypes. In MSRD, Ki67 was significantly linked to prognosis in uni- and multivariate analysis in the complete cohort and in HR-positive, but not triple-negative tumors. Ki67 is a significant predictive and prognostic marker over a wide range of cut points suggesting that data-derived cut point optimization might not be possible. Ki67 could be used as a continuous marker; in addition, the scientific community could define standardized cut points for Ki67. Our analysis explains the variability observed for Ki67 cut points in previous studies; however, this should not be seen as weakness, but as strength of this marker. MSRDs are an easy new approach for visualization of biomarker effects on outcome across molecular subtypes in breast cancer. The experience with Ki67 could provide important information regarding the development and implementation of other quantitative biomarkers.

  2. 49 CFR 572.144 - Thorax assembly and test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... dummy (drawing 210-0000) is impacted by a test probe conforming to § 572.146(a) at 6.0 ±0.1 m/s (19.7 ±0... corridor, the peak force, measured by the probe-mounted accelerometer as defined in § 572.146(a) and... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...

  3. 49 CFR 572.144 - Thorax assembly and test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... dummy (drawing 210-0000) is impacted by a test probe conforming to § 572.146(a) at 6.0 ±0.1 m/s (19.7 ±0... corridor, the peak force, measured by the probe-mounted accelerometer as defined in § 572.146(a) and... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...

  4. 49 CFR 572.144 - Thorax assembly and test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... dummy (drawing 210-0000) is impacted by a test probe conforming to § 572.146(a) at 6.0 ±0.1 m/s (19.7 ±0... corridor, the peak force, measured by the probe-mounted accelerometer as defined in § 572.146(a) and... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...

  5. 49 CFR 572.144 - Thorax assembly and test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... dummy (drawing 210-0000) is impacted by a test probe conforming to § 572.146(a) at 6.0 ±0.1 m/s (19.7 ±0... corridor, the peak force, measured by the probe-mounted accelerometer as defined in § 572.146(a) and... midsagittal plane so that the impact point of the longitudinal centerline of the probe coincides with the...

  6. Comparison of cutting and pencil-point spinal needle in spinal anesthesia regarding postdural puncture headache

    PubMed Central

    Xu, Hong; Liu, Yang; Song, WenYe; Kan, ShunLi; Liu, FeiFei; Zhang, Di; Ning, GuangZhi; Feng, ShiQing

    2017-01-01

    Abstract Background: Postdural puncture headache (PDPH), mainly resulting from the loss of cerebral spinal fluid (CSF), is a well-known iatrogenic complication of spinal anesthesia and diagnostic lumbar puncture. Spinal needles have been modified to minimize complications. Modifiable risk factors of PDPH mainly included needle size and needle shape. However, whether the incidence of PDPH is significantly different between cutting-point and pencil-point needles was controversial. Then we did a meta-analysis to assess the incidence of PDPH of cutting spinal needle and pencil-point spinal needle. Methods: We included all randomly designed trials, assessing the clinical outcomes in patients given elective spinal anesthesia or diagnostic lumbar puncture with either cutting or pencil-point spinal needle as eligible studies. All selected studies and the risk of bias of them were assessed by 2 investigators. Clinical outcomes including success rates, frequency of PDPH, reported severe PDPH, and the use of epidural blood patch (EBP) were recorded as primary results. Results were evaluated using risk ratio (RR) with 95% confidence interval (CI) for dichotomous variables. Rev Man software (version 5.3) was used to analyze all appropriate data. Results: Twenty-five randomized controlled trials (RCTs) were included in our study. The analysis result revealed that pencil-point spinal needle would result in lower rate of PDPH (RR 2.50; 95% CI [1.96, 3.19]; P < 0.00001) and severe PDPH (RR 3.27; 95% CI [2.15, 4.96]; P < 0.00001). Furthermore, EBP was less used in pencil-point spine needle group (RR 3.69; 95% CI [1.96, 6.95]; P < 0.0001). Conclusions: Current evidences suggest that pencil-point spinal needle was significantly superior compared with cutting spinal needle regarding the frequency of PDPH, PDPH severity, and the use of EBP. In view of this, we recommend the use of pencil-point spinal needle in spinal anesthesia and lumbar puncture. PMID:28383416

  7. Redefining Cut-Points for High Symptom Burden of the Global Initiative for Chronic Obstructive Lung Disease Classification in 18,577 Patients With Chronic Obstructive Pulmonary Disease.

    PubMed

    Smid, Dionne E; Franssen, Frits M E; Gonik, Maria; Miravitlles, Marc; Casanova, Ciro; Cosio, Borja G; de Lucas-Ramos, Pilar; Marin, Jose M; Martinez, Cristina; Mir, Isabel; Soriano, Joan B; de Torres, Juan P; Agusti, Alvar; Atalay, Nart B; Billington, Julia; Boutou, Afroditi K; Brighenti-Zogg, Stefanie; Chaplin, Emma; Coster, Samantha; Dodd, James W; Dürr, Selina; Fernandez-Villar, Alberto; Groenen, Miriam T J; Guimarães, Miguel; Hejduk, Karel; Higgins, Victoria; Hopkinson, Nicholas S; Horita, Nobuyuki; Houben-Wilke, Sarah; Janssen, Daisy J A; Jehn, Melissa; Joerres, Rudolf; Karch, Annika; Kelly, Julia L; Kim, Yu-Il; Kimura, Hiroshi; Koblizek, Vladimir; Kocks, Janwillem H; Kon, Samantha S C; Kwon, Namhee; Ladeira, Inês; Lee, Sang-Do; Leuppi, Joerg D; Locantore, Nicholas; Lopez-Campos, José L; D-C Man, William; Maricic, Lana; Mendoza, Laura; Miedinger, David; Mihaltan, Florin; Minami, Seigo; van der Molen, Thys; Murrells, Trevor J; Nakken, Nienke; Nishijima, Yu; Norman, Ian J; Novotna, Barbora; O'Donnell, Denis E; Ogata, Yoshitaka; Pereira, Eanes D; Piercy, James; Price, David; Pothirat, Chaicharn; Raghavan, Natya; Ringbaek, Thomas; Sajkov, Dimitar; Sigari, Naseh; Singh, Sally; Small, Mark; da Silva, Guilherme F; Tanner, Rebecca J; Tsiligianni, Ioanna G; Tulek, Baykal; Tzanakis, Nikolaos; Vanfleteren, Lowie E G W; Watz, Henrik; Webb, Katherine A; Wouters, Emiel F M; Xie, Guogang G; Yoshikawa, Masanori; Spruit, Martijn A

    2017-12-01

    Patients with chronic obstructive pulmonary disease (COPD) can be classified into groups A/C or B/D based on symptom intensity. Different threshold values for symptom questionnaires can result in misclassification and, in turn, different treatment recommendations. The primary aim was to find the best fitting cut-points for Global initiative for chronic Obstructive Lung Disease (GOLD) symptom measures, with an modified Medical Research Council dyspnea grade of 2 or higher as point of reference. After a computerized search, data from 41 cohorts and whose authors agreed to provide data were pooled. COPD studies were eligible for analyses if they included, at least age, sex, postbronchodilator spirometry, modified Medical Research Council, and COPD Assessment Test (CAT) total scores. Receiver operating characteristic curves and the Youden index were used to determine the best calibration threshold for CAT, COPD Clinical Questionnaire, and St. Georges Respiratory Questionnaire total scores. Following, GOLD A/B/C/D frequencies were calculated based on current cut-points and the newly derived cut-points. A total of 18,577 patients with COPD [72.0% male; mean age: 66.3 years (standard deviation 9.6)] were analyzed. Most patients had a moderate or severe degree of airflow limitation (GOLD spirometric grade 1, 10.9%; grade 2, 46.6%; grade 3, 32.4%; and grade 4, 10.3%). The best calibration threshold for CAT total score was 18 points, for COPD Clinical Questionnaire total score 1.9 points, and for St. Georges Respiratory Questionnaire total score 46.0 points. The application of these new cut-points would reclassify about one-third of the patients with COPD and, thus, would impact on individual disease management. Further validation in prospective studies of these new values are needed. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  8. A Self-Diagnostic System for the M6 Accelerometer

    NASA Technical Reports Server (NTRS)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  9. Raised BMI cut-off for overweight in Greenland Inuit--a review.

    PubMed

    Andersen, Stig; Fleischer Rex, Karsten; Noahsen, Paneeraq; Sørensen, Hans Christian Florian; Mulvad, Gert; Laurberg, Peter

    2013-01-01

    Obesity is associated with increased morbidity and premature death. Obesity rates have increased worldwide and the WHO recommends monitoring. A steep rise in body mass index (BMI), a measure of adiposity, was detected in Greenland from 1963 to 1998. Interestingly, the BMI starting point was in the overweight range. This is not conceivable in a disease-free, physically active, pre-western hunter population. This led us to reconsider the cut-off point for overweight among Inuit in Greenland. We found 3 different approaches to defining the cut-off point of high BMI in Inuit. First, the contribution to the height by the torso compared to the legs is relatively high. This causes relatively more kilograms per centimetre of height that increases the BMI by approximately 10% compared to Caucasian whites. Second, defining the cut-off by the upper 90-percentile of BMI from height and weight in healthy young Inuit surveyed in 1963 estimated the cut-off point to be around 10% higher compared to Caucasians. Third, if similar LDL-cholesterol and triglycerides are assumed for a certain BMI in Caucasians, the corresponding BMI in Inuit in both Greenland and Canada is around 10% higher. However, genetic admixture of Greenland Inuit and Caucasian Danes will influence this difference and hamper a clear distinction with time. Defining overweight according to the WHO cut-off of a BMI above 25 kg/m(2) in Greenland Inuit may overestimate the number of individuals with elevated BMI.

  10. Raised BMI cut-off for overweight in Greenland Inuit – a review

    PubMed Central

    Andersen, Stig; Fleischer Rex, Karsten; Noahsen, Paneeraq; Sørensen, Hans Christian Florian; Mulvad, Gert; Laurberg, Peter

    2013-01-01

    Background Obesity is associated with increased morbidity and premature death. Obesity rates have increased worldwide and the WHO recommends monitoring. A steep rise in body mass index (BMI), a measure of adiposity, was detected in Greenland from 1963 to 1998. Interestingly, the BMI starting point was in the overweight range. This is not conceivable in a disease-free, physically active, pre-western hunter population. Objective This led us to reconsider the cut-off point for overweight among Inuit in Greenland. Design and findings We found 3 different approaches to defining the cut-off point of high BMI in Inuit. First, the contribution to the height by the torso compared to the legs is relatively high. This causes relatively more kilograms per centimetre of height that increases the BMI by approximately 10% compared to Caucasian whites. Second, defining the cut-off by the upper 90-percentile of BMI from height and weight in healthy young Inuit surveyed in 1963 estimated the cut-off point to be around 10% higher compared to Caucasians. Third, if similar LDL-cholesterol and triglycerides are assumed for a certain BMI in Caucasians, the corresponding BMI in Inuit in both Greenland and Canada is around 10% higher. However, genetic admixture of Greenland Inuit and Caucasian Danes will influence this difference and hamper a clear distinction with time. Conclusion Defining overweight according to the WHO cut-off of a BMI above 25 kg/m2 in Greenland Inuit may overestimate the number of individuals with elevated BMI. PMID:23986904

  11. Starting Trees from Cuttings.

    ERIC Educational Resources Information Center

    Kramer, David C.

    1983-01-01

    Describes a procedure for starting tree cuttings from woody plants, explaining "lag time," recommending materials, and giving step-by-step instructions for rooting and planting. Points out species which are likely candidates for cuttings and provides tips for teachers for developing a unit. (JM)

  12. Liebowitz Social Anxiety Scale (LSAS): Optimal cut points for remission and response in a German sample.

    PubMed

    von Glischinski, M; Willutzki, U; Stangier, U; Hiller, W; Hoyer, J; Leibing, E; Leichsenring, F; Hirschfeld, G

    2018-02-11

    The Liebowitz Social Anxiety Scale (LSAS) is the most frequently used instrument to assess social anxiety disorder (SAD) in clinical research and practice. Both a self-reported (LSAS-SR) and a clinician-administered (LSAS-CA) version are available. The aim of the present study was to define optimal cut-off (OC) scores for remission and response to treatment for the LSAS in a German sample. Data of N = 311 patients with SAD were used who had completed psychotherapeutic treatment within a multicentre randomized controlled trial. Diagnosis of SAD and reduction in symptom severity according to the Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, 4th edition, served as gold standard. OCs yielding the best balance between sensitivity and specificity were determined using receiver operating characteristics. The variability of the resulting OCs was estimated by nonparametric bootstrapping. Using diagnosis of SAD (present vs. absent) as a criterion, results for remission indicated cut-off values of 35 for the LSAS-SR and 30 for the LSAS-CA, with acceptable sensitivity (LSAS-SR: .83, LSAS-CA: .88) and specificity (LSAS-SR: .82, LSAS-CA: .87). For detection of response to treatment, assessed by a 1-point reduction in the Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders, 4th edition, rating, a reduction of 28% for the LSAS-SR and 29% for the LSAS-CA yielded the best balance between sensitivity (LSAS-SR: .75, LSAS-CA: .83) and specificity (LSAS-SR: .76, LSAS-CA: .80). To our knowledge, we are the first to define cut points for the LSAS in a German sample. Overall, the cut points for remission and response corroborate previously reported cut points, now building on a broader data basis. Copyright © 2018 John Wiley & Sons, Ltd.

  13. The Development of a Dual-Warhead Impact System for Dynamic Linearity Measurement of a High-g Micro-Electro-Mechanical-Systems (MEMS) Accelerometer

    PubMed Central

    Shi, Yunbo; Yang, Zhicai; Ma, Zongmin; Cao, Huiliang; Kou, Zhiwei; Zhi, Dan; Chen, Yanxiang; Feng, Hengzhen; Liu, Jun

    2016-01-01

    Despite its extreme significance, dynamic linearity measurement for high-g accelerometers has not been discussed experimentally in previous research. In this study, we developed a novel method using a dual-warhead Hopkinson bar to measure the dynamic linearity of a high-g acceleration sensor with a laser interference impact experiment. First, we theoretically determined that dynamic linearity is a performance indicator that can be used to assess the quality merits of high-g accelerometers and is the basis of the frequency response. We also found that the dynamic linearity of the dual-warhead Hopkinson bar without an accelerometer is 2.5% experimentally. Further, we verify that dynamic linearity of the accelerometer is 3.88% after calibrating the Hopkinson bar with the accelerometer. The results confirm the reliability and feasibility of measuring dynamic linearity for high-g accelerometers using this method. PMID:27338383

  14. A biomimetic accelerometer inspired by the cricket's clavate hair

    PubMed Central

    Droogendijk, H.; de Boer, M. J.; Sanders, R. G. P.; Krijnen, G. J. M.

    2014-01-01

    Crickets use so-called clavate hairs to sense (gravitational) acceleration to obtain information on their orientation. Inspired by this clavate hair system, a one-axis biomimetic accelerometer has been developed and fabricated using surface micromachining and SU-8 lithography. An analytical model is presented for the design of the accelerometer, and guidelines are derived to reduce responsivity due to flow-induced contributions to the accelerometer's output. Measurements show that this microelectromechanical systems (MEMS) hair-based accelerometer has a resonance frequency of 320 Hz, a detection threshold of 0.10 ms−2 and a dynamic range of more than 35 dB. The accelerometer exhibits a clear directional response to external accelerations and a low responsivity to airflow. Further, the accelerometer's physical limits with respect to noise levels are addressed and the possibility for short-term adaptation of the sensor to the environment is discussed. PMID:24920115

  15. Dual Accelerometer Usage Strategy for Onboard Space Navigation

    NASA Technical Reports Server (NTRS)

    Zanetti, Renato; D'Souza, Chris

    2012-01-01

    This work introduces a dual accelerometer usage strategy for onboard space navigation. In the proposed algorithm the accelerometer is used to propagate the state when its value exceeds a threshold and it is used to estimate its errors otherwise. Numerical examples and comparison to other accelerometer usage schemes are presented to validate the proposed approach.

  16. A Subnano-g Electrostatic Force-Rebalanced Flexure Accelerometer for Gravity Gradient Instruments

    PubMed Central

    Yan, Shitao; Xie, Yafei; Zhang, Mengqi; Deng, Zhongguang

    2017-01-01

    A subnano-g electrostatic force-rebalanced flexure accelerometer is designed for the rotating accelerometer gravity gradient instrument. This accelerometer has a large proof mass, which is supported inversely by two pairs of parallel leaf springs and is centered between two fixed capacitor plates. This novel design enables the proof mass to move exactly along the sensitive direction and exhibits a high rejection ratio at its cross-axis directions. Benefiting from large proof mass, high vacuum packaging, and air-tight sealing, the thermal Brownian noise of the accelerometer is lowered down to less than 0.2 ng/Hz with a quality factor of 15 and a natural resonant frequency of about 7.4 Hz. The accelerometer’s designed measurement range is about ±1 mg. Based on the correlation analysis between a commercial triaxial seismometer and our accelerometer, the demonstrated self-noise of our accelerometers is reduced to lower than 0.3 ng/Hz over the frequency ranging from 0.2 to 2 Hz, which meets the requirement of the rotating accelerometer gravity gradiometer. PMID:29156587

  17. The analysis of temperature effect and temperature compensation of MOEMS accelerometer based on a grating interferometric cavity

    NASA Astrophysics Data System (ADS)

    Han, Dandan; Bai, Jian; Lu, Qianbo; Lou, Shuqi; Jiao, Xufen; Yang, Guoguang

    2016-08-01

    There is a temperature drift of an accelerometer attributed to the temperature variation, which would adversely influence the output performance. In this paper, a quantitative analysis of the temperature effect and the temperature compensation of a MOEMS accelerometer, which is composed of a grating interferometric cavity and a micromachined sensing chip, are proposed. A finite-element-method (FEM) approach is applied in this work to simulate the deformation of the sensing chip of the MOEMS accelerometer at different temperature from -20°C to 70°C. The deformation results in the variation of the distance between the grating and the sensing chip of the MOEMS accelerometer, modulating the output intensities finally. A static temperature model is set up to describe the temperature characteristics of the accelerometer through the simulation results and the temperature compensation is put forward based on the temperature model, which can improve the output performance of the accelerometer. This model is permitted to estimate the temperature effect of this type accelerometer, which contains a micromachined sensing chip. Comparison of the output intensities with and without temperature compensation indicates that the temperature compensation can improve the stability of the output intensities of the MOEMS accelerometer based on a grating interferometric cavity.

  18. Using tri-axial accelerometers to identify wild polar bear behaviors

    USGS Publications Warehouse

    Pagano, Anthony M.; Rode, Karyn D.; Cutting, A.; Owen, M.A.; Jensen, S.; Ware, J.V.; Robbins, C.T.; Durner, George M.; Atwood, Todd C.; Obbard, M.E.; Middel, K.R.; Thiemann, G.W.; Williams, T.M.

    2017-01-01

    Tri-axial accelerometers have been used to remotely identify the behaviors of a wide range of taxa. Assigning behaviors to accelerometer data often involves the use of captive animals or surrogate species, as their accelerometer signatures are generally assumed to be similar to those of their wild counterparts. However, this has rarely been tested. Validated accelerometer data are needed for polar bears Ursus maritimus to understand how habitat conditions may influence behavior and energy demands. We used accelerometer and water conductivity data to remotely distinguish 10 polar bear behaviors. We calibrated accelerometer and conductivity data collected from collars with behaviors observed from video-recorded captive polar bears and brown bears U. arctos, and with video from camera collars deployed on free-ranging polar bears on sea ice and on land. We used random forest models to predict behaviors and found strong ability to discriminate the most common wild polar bear behaviors using a combination of accelerometer and conductivity sensor data from captive or wild polar bears. In contrast, models using data from captive brown bears failed to reliably distinguish most active behaviors in wild polar bears. Our ability to discriminate behavior was greatest when species- and habitat-specific data from wild individuals were used to train models. Data from captive individuals may be suitable for calibrating accelerometers, but may provide reduced ability to discriminate some behaviors. The accelerometer calibrations developed here provide a method to quantify polar bear behaviors to evaluate the impacts of declines in Arctic sea ice.

  19. Diagnostic value of sputum adenosine deaminase (ADA) level in pulmonary tuberculosis.

    PubMed

    Binesh, Fariba; Jalali, Hadi; Zare, Mohammad Reza; Behravan, Farhad; Tafti, Arefeh Dehghani; Behnaz, Fatemah; Tabatabaee, Mohammad; Shahcheraghi, Seyed Hossein

    2016-06-01

    Tuberculosis is still a considerable health problem in many countries. Rapid diagnosis of this disease is important, and adenosine deaminase (ADA) has been used as a diagnostic test. The aim of this study was to assess the diagnostic value of ADA in the sputum of patients with pulmonary tuberculosis. The current study included 40 patients with pulmonary tuberculosis (culture positive, smear ±) and 42 patients with non tuberculosis pulmonary diseases (culture negative). ADA was measured on all of the samples. The median value of ADA in non-tuberculosis patients was 2.94 (4.2) U/L and 4.01 (6.54) U/L in tuberculosis patients, but this difference was not statistically significant (p=0.100). The cut-off point of 3.1 U/L had a sensitivity of 61% and a specificity of 53%, the cut-off point of 2.81 U/L had a sensitivity of 64% and a specificity of 50% and the cut-off point of 2.78 U/L had a sensitivity of 65% and a specificity of 48%. The positive predictive values for cut-off points of 3.1, 2.81 and 2.78 U/L were 55.7%, 57.44% and 69.23%, respectively. The negative predictive values for the abovementioned cut-off points were 56.75%, 57.14% and 55.88%, respectively. Our results showed that sputum ADA test is neither specific nor sensitive. Because of its low sensitivity and specificity, determination of sputum ADA for the diagnosis of pulmonary tuberculosis is not recommended.

  20. Circulating intact and cleaved forms of the urokinase-type plasminogen activator receptor: biological variation, reference intervals and clinical useful cut-points.

    PubMed

    Thurison, Tine; Christensen, Ib J; Lund, Ida K; Nielsen, Hans J; Høyer-Hansen, Gunilla

    2015-01-15

    High levels of circulating forms of the urokinase-type plasminogen activator receptor (uPAR) are significantly associated to poor prognosis in cancer patients. Our aim was to determine biological variations and reference intervals of the uPAR forms in blood, and in addition, to test the clinical relevance of using these as cut-points in colorectal cancer (CRC) prognosis. uPAR forms were measured in citrated and EDTA plasma samples using time-resolved fluorescence immunoassays. Diurnal, intra- and inter-individual variations were assessed in plasma samples from cohorts of healthy individuals. Reference intervals were determined in plasma from healthy individuals randomly selected from a Danish multi-center cross-sectional study. A cohort of CRC patients was selected from the same cross-sectional study. The reference intervals showed a slight increase with age and women had ~20% higher levels. The intra- and inter-individual variations were ~10% and ~20-30%, respectively and the measured levels of the uPAR forms were within the determined 95% reference intervals. No diurnal variation was found. Applying the normal upper limit of the reference intervals as cut-point for dichotomizing CRC patients revealed significantly decreased overall survival of patients with levels above this cut-point of any uPAR form. The reference intervals for the different uPAR forms are valid and the upper normal limits are clinically relevant cut-points for CRC prognosis. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Optimal accelerometer placement on a robot arm for pose estimation

    NASA Astrophysics Data System (ADS)

    Wijayasinghe, Indika B.; Sanford, Joseph D.; Abubakar, Shamsudeen; Saadatzi, Mohammad Nasser; Das, Sumit K.; Popa, Dan O.

    2017-05-01

    The performance of robots to carry out tasks depends in part on the sensor information they can utilize. Usually, robots are fitted with angle joint encoders that are used to estimate the position and orientation (or the pose) of its end-effector. However, there are numerous situations, such as in legged locomotion, mobile manipulation, or prosthetics, where such joint sensors may not be present at every, or any joint. In this paper we study the use of inertial sensors, in particular accelerometers, placed on the robot that can be used to estimate the robot pose. Studying accelerometer placement on a robot involves many parameters that affect the performance of the intended positioning task. Parameters such as the number of accelerometers, their size, geometric placement and Signal-to-Noise Ratio (SNR) are included in our study of their effects for robot pose estimation. Due to the ubiquitous availability of inexpensive accelerometers, we investigated pose estimation gains resulting from using increasingly large numbers of sensors. Monte-Carlo simulations are performed with a two-link robot arm to obtain the expected value of an estimation error metric for different accelerometer configurations, which are then compared for optimization. Results show that, with a fixed SNR model, the pose estimation error decreases with increasing number of accelerometers, whereas for a SNR model that scales inversely to the accelerometer footprint, the pose estimation error increases with the number of accelerometers. It is also shown that the optimal placement of the accelerometers depends on the method used for pose estimation. The findings suggest that an integration-based method favors placement of accelerometers at the extremities of the robot links, whereas a kinematic-constraints-based method favors a more uniformly distributed placement along the robot links.

  2. Comparison of Physical Activity Adult Questionnaire results with accelerometer data.

    PubMed

    Garriguet, Didier; Tremblay, Sylvain; Colley, Rachel C

    2015-07-01

    Discrepancies between self-reported and objectively measured physical activity are well-known. For the purpose of validation, this study compares a new self-reported physical activity questionnaire with an existing one and with accelerometer data. Data collected at one site of the Canadian Health Measures Survey in 2013 were used for this validation study. The International Physical Activity Questionnaire (IPAQ) was administered to respondents during the household interview, and the new Physical Activity for Adults Questionnaire (PAAQ) was administered during a subsequent visit to a mobile examination centre (MEC). At the MEC, respondents were given an accelerometer to wear for seven days. The analysis pertains to 112 respondents aged 18 to 79 who wore the accelerometer for 10 or more hours on at least four days. Moderate-to-vigorous physical activity (MVPA) measured by accelerometer had higher correlation with data from the PAAQ (r = 0.44) than with data from the IPAQ (r = 0.20). The differences between accelerometer and PAAQ data were greater based on accelerometer-measured physical activity accumulated in 10-minute bouts (30-minute difference in MVPA) than on all minutes (9-minute difference). The percentages of respondents meeting the Canadian Physical Activity Guidelines were 90% based on self-reported IPAQ minutes, 70% based on all accelerometer MVPA minutes, 29% based on accelerometer MVPA minutes accumulated in 10-minute bouts, and 61% based on self-reported PAAQ minutes. The PAAQ demonstrated reasonable validity against the accelerometer criterion. Based on correlations and absolute differences between daily minutes of MVPA and the percentages of respondents meeting the Canadian Physical Activity Guidelines, PAAQ results were closer to accelerometer data than were the IPAQ results for the study sample and previous Statistics Canada self-reported questionnaire findings.

  3. Diagnostic accuracy of HbA1c in diabetes between Eastern and Western.

    PubMed

    Yan, Shuang; Liu, Siying; Zhao, Yashuang; Zhang, Wencui; Sun, Xiaohui; Li, Jianing; Jiang, Fuli; Ju, Jiaming; Lang, Ning; Zhang, Yingqi; Zhou, Weiyu; Li, Qiang

    2013-07-01

    In 2010, the American Diabetes Association recommended the use of HbA1c as a diagnostic criterion for diabetes. However, HbA1c is not an accepted diagnostic tool for diabetes in Eastern Asia, because genetic differences compromise the standardization of the diagnostic cut-off point. This study evaluated differences in the use of HbA1c for diagnosing diabetes in Eastern and Western populations and investigated whether HbA1c cut-off point of ≥ 6.5% is diagnostic of diabetes in patients from Eastern Asia. Literature was obtained from MEDLINE, EMBASE and Cochrane databases. The pooled sensitivity and specificity of each HbA1c cut-off point were extracted and compared between Western and Eastern populations. Differences in the cut-off point for diagnosing diabetes in each region were compared by examining differences in the area under summary receiver operating characteristic (SROC) curves. Twelve publications from Eastern countries (n = 59,735) and 13 from Western countries (n = 22,954) were included in the analysis. Areas under SROC curves in the Eastern and Western groups were 0.9331 and 0.9120, respectively (P = 0.98). The cut-off point of the highest Youden index was 6.0%. At the HbA1c cut-off point of 6.5%, the pooled sensitivity and specificity were 58.7% and 98.4% for Eastern countries and 65.5% and 98.1% for Western countries, respectively. HbA1c exhibits the same diagnostic value for diabetes in Eastern and Western populations. In both populations, HbA1c levels > 6.0% identify the population at high risk of diabetes, and HbA1c > 6.5% is diagnostic of clinically established diabetes. © 2013 Stichting European Society for Clinical Investigation Journal Foundation. Published by John Wiley & Sons Ltd.

  4. Using ROC Curves to Choose Minimally Important Change Thresholds when Sensitivity and Specificity Are Valued Equally: The Forgotten Lesson of Pythagoras. Theoretical Considerations and an Example Application of Change in Health Status

    PubMed Central

    Froud, Robert; Abel, Gary

    2014-01-01

    Background Receiver Operator Characteristic (ROC) curves are being used to identify Minimally Important Change (MIC) thresholds on scales that measure a change in health status. In quasi-continuous patient reported outcome measures, such as those that measure changes in chronic diseases with variable clinical trajectories, sensitivity and specificity are often valued equally. Notwithstanding methodologists agreeing that these should be valued equally, different approaches have been taken to estimating MIC thresholds using ROC curves. Aims and objectives We aimed to compare the different approaches used with a new approach, exploring the extent to which the methods choose different thresholds, and considering the effect of differences on conclusions in responder analyses. Methods Using graphical methods, hypothetical data, and data from a large randomised controlled trial of manual therapy for low back pain, we compared two existing approaches with a new approach that is based on the addition of the sums of squares of 1-sensitivity and 1-specificity. Results There can be divergence in the thresholds chosen by different estimators. The cut-point selected by different estimators is dependent on the relationship between the cut-points in ROC space and the different contours described by the estimators. In particular, asymmetry and the number of possible cut-points affects threshold selection. Conclusion Choice of MIC estimator is important. Different methods for choosing cut-points can lead to materially different MIC thresholds and thus affect results of responder analyses and trial conclusions. An estimator based on the smallest sum of squares of 1-sensitivity and 1-specificity is preferable when sensitivity and specificity are valued equally. Unlike other methods currently in use, the cut-point chosen by the sum of squares method always and efficiently chooses the cut-point closest to the top-left corner of ROC space, regardless of the shape of the ROC curve. PMID:25474472

  5. Transcutaneous oxygen pressure measurement in diabetic foot ulcers: mean values and cut-point for wound healing.

    PubMed

    Yang, Chuan; Weng, Huan; Chen, Lihong; Yang, Haiyun; Luo, Guangming; Mai, Lifang; Jin, Guoshu; Yan, Li

    2013-01-01

    The purpose of this study was to investigate mean values and cut-point of transcutaneous oxygen pressure (TcPO2) measurement in patients with diabetic foot ulcers. Prospective, descriptive study. Sixty-one patients with diabetes mellitus and foot ulcers comprised the sample. The research setting was Sun Yat-sen Memorial Hospital of SunYat-sen University, Guangzhou, China. Participants underwent transcutaneous oxygen (TcPO2) measurement at the dorsum of foot. Patients were classified into 3 groups according to clinical outcomes: (1) ulcers healed with intact skin group, (2) ulcer improved, and (3) ulcer failed to improve. TcPO2 was assessed and cut-points for predicting diabetic foot ulcer healing were calculated. Thirty-six patients healed with intact skin, 8 experienced improvement, and 17 showed no improvement. Mean TcPO2 levels were significantly higher (P< .001) in healed ulcers with intact skin (32 ± 10 mmHg) when compared to the improvement group (30 ± 7 mmHg) and the nonhealing group (15 ± 12 mmHg). All patients with TcPO2≤ 10 mmHg failed to heal or experienced deterioration in their foot ulcers. In contrast, all patients with TcPO2≥ 40 mmHg achieved wound closure. Measurement of TcPO2 in the supine position revealed a cut-point value of 25 mmHg as the best threshold for predicting diabetic foot ulcer healing; the area under the curve using this cut-point was 0.838 (95% confidence interval = 0.700-0.976). The sensitivity, specificity, positive predictive value, and negative predictive value for TxPO2 were 88.6%, 82.4%, 90.7%, and 72.2%, respectively. TcPO2≥ 40 mmHg was associated with diabetic foot ulcer healing, but a TcPO2≤ 10 mmHg was associated with failure of wound healing. We found that a cut-point of 25 mmHg was most predictive of diabetic foot ulcer healing.

  6. Clinically Relevant Cut-off Points for the Diagnosis of Sarcopenia in Older Korean People.

    PubMed

    Choe, Yu-Ri; Joh, Ju-Youn; Kim, Yeon-Pyo

    2017-11-09

    The optimal criteria applied to older Korean people have not been defined. We aimed to define clinically relevant cut-off points for older Korean people and to compare the predictive validity with other definitions of sarcopenia. Nine hundred and sixteen older Koreans (≥65 years) were included in this cross-sectional observational study. We used conditional inference tree analysis to determine cut-off points for height-adjusted grip strength (GS) and appendicular skeletal muscle mass (ASM), for use in the diagnosis of sarcopenia. We then compared the Korean sarcopenia criteria with the Foundation for the National Institutes of Health and Asian Working Group for Sarcopenia criteria, using frailty, assessed with the Korean Frailty Index, as an outcome variable. For men, a residual GS (GSre) of ≤ 0.25 was defined as weak, and a residual ASM (ASMre) of ≤ 1.29 was defined as low. Corresponding cut-off points for women were a GSre of ≤ 0.17 and an ASMre of ≤ 0.69. GSre and ASMre values were adjusted for height. In logistic regression analysis with new cut-off points, the adjusted odds ratios for pre-frail or frail status in the sarcopenia group were 3.23 (95% confidence interval [CI] 1.33-7.83) for the men and 1.74 (95% CI 0.91-3.35) for the women. In receiver operating characteristic curve analysis, the unadjusted area under the curve for Korean sarcopenia criteria in men and women were 0.653 and 0.608, respectively (p < .001). Our proposed cut-off points for low GS and low ASM should be useful in the diagnosis of sarcopenia in older Korean people. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Cutting efficiency of air-turbine burs on cast titanium and dental casting alloys.

    PubMed

    Watanabe, I; Ohkubo, C; Ford, J P; Atsuta, M; Okabe, T

    2000-11-01

    The purpose of this study was to investigate the cutting efficiency of air-turbine burs on cast free-machining titanium alloy (DT2F) and to compare the results with those for cast commercially pure (CP) Ti, Ti-6Al-4V alloy, and dental casting alloys. The cast metal (DT2F, CP Ti, Ti-6Al-4V, Type IV gold alloy and Co-Cr alloy) specimens were cut with air-turbine burs (carbide burs and diamond points) at air pressures of 138 or 207 kPa and a cutting force of 0.784 N. The cutting efficiency of each bur was evaluated as volume loss calculated from the weight loss cut for 5 s and the density of each metal. The bulk microhardness was measured to correlate the machinability and the hardness of each metal. The amounts of DT2F cut with the carbide burs were significantly (p < 0.05) greater than for the other titanium specimens at either 138 or 207 kPa. The diamond points exhibited similar machining efficiency among all metals except for Type IV gold alloy. The increase in the volume loss of Co-Cr alloy (Vitallium) cut with the diamond points showed a negative value (-29%) with an increase in air pressure from 138 to 207 kPa. There was a negative correlation between the amounts of metal removed (volume loss) and the hardness (r2 = 0.689) when the carbide burs were used. The results of this study indicated that a free-machining titanium alloy (DT2F) exhibited better machinability compared to CP Ti and Ti-6Al-4V alloy when using carbide fissure burs. When machining cast CP Ti and its alloys, carbide fissure burs possessed a greater machining efficiency than the diamond points and are recommended for titanium dental prostheses.

  8. Identification of the critical depth-of-cut through a 2D image of the cutting region resulting from taper cutting of brittle materials

    NASA Astrophysics Data System (ADS)

    Gu, Wen; Zhu, Zhiwei; Zhu, Wu-Le; Lu, Leyao; To, Suet; Xiao, Gaobo

    2018-05-01

    An automatic identification method for obtaining the critical depth-of-cut (DoC) of brittle materials with nanometric accuracy and sub-nanometric uncertainty is proposed in this paper. With this method, a two-dimensional (2D) microscopic image of the taper cutting region is captured and further processed by image analysis to extract the margin of generated micro-cracks in the imaging plane. Meanwhile, an analytical model is formulated to describe the theoretical curve of the projected cutting points on the imaging plane with respect to a specified DoC during the whole cutting process. By adopting differential evolution algorithm-based minimization, the critical DoC can be identified by minimizing the deviation between the extracted margin and the theoretical curve. The proposed method is demonstrated through both numerical simulation and experimental analysis. Compared with conventional 2D- and 3D-microscopic-image-based methods, determination of the critical DoC in this study uses the envelope profile rather than the onset point of the generated cracks, providing a more objective approach with smaller uncertainty.

  9. The CDC and IOTF cut points show inconsistent prevalence of underweight and overweight in chinese, indonesian, and vietnamese children

    USDA-ARS?s Scientific Manuscript database

    No nationally representative data from middle and low-income countries have been analyzed to compare prevalence of underweight and overweight defined by the Centers for Disease Control and Prevention (CDC) and the International Obesity Task Force (IOTF) BMI cut points. We evaluated the consistency i...

  10. [Validation of the nutritional index in Mexican pre-teens with the sensitivity and specificity method].

    PubMed

    Saucedo-Molina, T J; Gómez-Peresmitré, G

    1998-01-01

    To determine the diagnostic validity of the nutritional index (NI) in a sample of Mexican preadolescents. A total of 256 preadolescents, between 10 and 12 years old, male and female, students from Mexico City, were used to establish the diagnostic validity of NI using the sensitivity and specificity method. The findings show that the conventional NI cut-off points showed good sensitivity and specificity for the diagnosis of low weight, normality and obesity but not for overweight. When the cut-off points of NI were normalized, the sensitivity, specificity and prediction potency values were more suitable in all categories. When working with preadolescents, it is better to use the new cut-off points of NI, to obtain more reliable diagnosis.

  11. Self Diagnostic Accelerometer Testing on the C-17 Aircraft

    NASA Technical Reports Server (NTRS)

    Tokars, Roger P.; Lekki, John D.

    2013-01-01

    The self diagnostic accelerometer (SDA) developed by the NASA Glenn Research Center was tested for the first time in an aircraft engine environment as part of the Vehicle Integrated Propulsion Research (VIPR) program. The VIPR program includes testing multiple critical flight sensor technologies. One such sensor, the accelerometer, measures vibrations to detect faults in the engine. In order to rely upon the accelerometer, the health of the accelerometer must be ensured. The SDA is a sensor system designed to actively determine the accelerometer structural health and attachment condition, in addition to vibration measurements. The SDA uses a signal conditioning unit that sends an electrical chirp to the accelerometer and recognizes changes in the response due to changes in the accelerometer health and attachment condition. To demonstrate the SDAs flight worthiness and robustness, multiple SDAs were mounted and tested on a C-17 aircraft engine. The engine test conditions varied from engine off, to idle, to maximum power. The SDA attachment conditions were varied from fully tight to loose. The newly developed SDA health algorithm described herein uses cross correlation pattern recognition to discriminate a healthy from a faulty SDA. The VIPR test results demonstrate for the first.

  12. A brief test of the Hewlett-Packard MEMS seismic accelerometer

    USGS Publications Warehouse

    Homeijer, Brian D.; Milligan, Donald J.; Hutt, Charles R.

    2014-01-01

    Testing was performed on a prototype of Hewlett-Packard (HP) Micro-Electro-Mechanical Systems (MEMS) seismic accelerometer at the U.S. Geological Survey’s Albuquerque Seismological Laboratory. This prototype was built using discrete electronic components. The self-noise level was measured during low seismic background conditions and found to be 9.8 ng/√Hz at periods below 0.2 s (frequencies above 5 Hz). The six-second microseism noise was also discernible. The HP MEMS accelerometer was compared to a Geotech Model GS-13 reference seismometer during seismic noise and signal levels well above the self-noise of the accelerometer. Matching power spectral densities (corrected for accelerometer and seismometer responses to represent true ground motion) indicated that the HP MEMS accelerometer has a flat (constant) response to acceleration from 0.0125 Hz to at least 62.5 Hz. Tilt calibrations of the HP MEMS accelerometer verified that the flat response to acceleration extends to 0 Hz. Future development of the HP MEMS accelerometer includes replacing the discreet electronic boards with a low power application-specific integrated circuit (ASIC) and increasing the dynamic range of the sensor to detect strong motion signals above one gravitational acceleration, while maintaining the self-noise observed during these tests.

  13. Vibration sensing in smart machine rotors using internal MEMS accelerometers

    NASA Astrophysics Data System (ADS)

    Jiménez, Samuel; Cole, Matthew O. T.; Keogh, Patrick S.

    2016-09-01

    This paper presents a novel topology for enhanced vibration sensing in which wireless MEMS accelerometers embedded within a hollow rotor measure vibration in a synchronously rotating frame of reference. Theoretical relations between rotor-embedded accelerometer signals and the vibration of the rotor in an inertial reference frame are derived. It is thereby shown that functionality as a virtual stator-mounted displacement transducer can be achieved through appropriate signal processing. Experimental tests on a prototype rotor confirm that both magnitude and phase information of synchronous vibration can be measured directly without additional stator-mounted key-phasor sensors. Displacement amplitudes calculated from accelerometer signals will become erroneous at low rotational speeds due to accelerometer zero-g offsets, hence a corrective procedure is introduced. Impact tests are also undertaken to examine the ability of the internal accelerometers to measure transient vibration. A further capability is demonstrated, whereby the accelerometer signals are used to measure rotational speed of the rotor by analysing the signal component due to gravity. The study highlights the extended functionality afforded by internal accelerometers and demonstrates the feasibility of internal sensor topologies, which can provide improved observability of rotor vibration at externally inaccessible rotor locations.

  14. The Relationship of Three-Dimensional Human Skull Motion to Brain Tissue Deformation in Magnetic Resonance Elastography Studies

    PubMed Central

    Badachhape, Andrew A.; Okamoto, Ruth J.; Durham, Ramona S.; Efron, Brent D.; Nadell, Sam J.; Johnson, Curtis L.; Bayly, Philip V.

    2017-01-01

    In traumatic brain injury (TBI), membranes such as the dura mater, arachnoid mater, and pia mater play a vital role in transmitting motion from the skull to brain tissue. Magnetic resonance elastography (MRE) is an imaging technique developed for noninvasive estimation of soft tissue material parameters. In MRE, dynamic deformation of brain tissue is induced by skull vibrations during magnetic resonance imaging (MRI); however, skull motion and its mode of transmission to the brain remain largely uncharacterized. In this study, displacements of points in the skull, reconstructed using data from an array of MRI-safe accelerometers, were compared to displacements of neighboring material points in brain tissue, estimated from MRE measurements. Comparison of the relative amplitudes, directions, and temporal phases of harmonic motion in the skulls and brains of six human subjects shows that the skull–brain interface significantly attenuates and delays transmission of motion from skull to brain. In contrast, in a cylindrical gelatin “phantom,” displacements of the rigid case (reconstructed from accelerometer data) were transmitted to the gelatin inside (estimated from MRE data) with little attenuation or phase lag. This quantitative characterization of the skull–brain interface will be valuable in the parameterization and validation of computer models of TBI. PMID:28267188

  15. The Relationship of Three-Dimensional Human Skull Motion to Brain Tissue Deformation in Magnetic Resonance Elastography Studies.

    PubMed

    Badachhape, Andrew A; Okamoto, Ruth J; Durham, Ramona S; Efron, Brent D; Nadell, Sam J; Johnson, Curtis L; Bayly, Philip V

    2017-05-01

    In traumatic brain injury (TBI), membranes such as the dura mater, arachnoid mater, and pia mater play a vital role in transmitting motion from the skull to brain tissue. Magnetic resonance elastography (MRE) is an imaging technique developed for noninvasive estimation of soft tissue material parameters. In MRE, dynamic deformation of brain tissue is induced by skull vibrations during magnetic resonance imaging (MRI); however, skull motion and its mode of transmission to the brain remain largely uncharacterized. In this study, displacements of points in the skull, reconstructed using data from an array of MRI-safe accelerometers, were compared to displacements of neighboring material points in brain tissue, estimated from MRE measurements. Comparison of the relative amplitudes, directions, and temporal phases of harmonic motion in the skulls and brains of six human subjects shows that the skull-brain interface significantly attenuates and delays transmission of motion from skull to brain. In contrast, in a cylindrical gelatin "phantom," displacements of the rigid case (reconstructed from accelerometer data) were transmitted to the gelatin inside (estimated from MRE data) with little attenuation or phase lag. This quantitative characterization of the skull-brain interface will be valuable in the parameterization and validation of computer models of TBI.

  16. Capturing Ultraviolet Radiation Exposure and Physical Activity: Feasibility Study and Comparison Between Self-Reports, Mobile Apps, Dosimeters, and Accelerometers

    PubMed Central

    Allen, Martin; Nathan, Andrea; Lowe, John; Janda, Monika

    2018-01-01

    Background Skin cancer is the most prevalent cancer in Australia. Skin cancer prevention programs aim to reduce sun exposure and increase sun protection behaviors. Effectiveness is usually assessed through self-report. Objective It was the aim of this study to test the acceptance and validity of a newly developed ultraviolet radiation (UVR) exposure app, designed to reduce the data collection burden to research participants. Physical activity data was collected because a strong focus on sun avoidance may result in unhealthy reductions in physical activity. This paper provides lessons learned from collecting data from participants using paper diaries, a mobile app, dosimeters, and accelerometers for measuring end-points of UVR exposure and physical activity. Methods Two participant groups were recruited through social and traditional media campaigns 1) Group A—UVR Diaries and 2) Group B—Physical Activity. In Group A, nineteen participants wore an UVR dosimeter wristwatch (University of Canterbury, New Zealand) when outside for 7 days. They also recorded their sun exposure and physical activity levels using both 1) the UVR diary app and 2) a paper UVR diary. In Group B, 55 participants wore an accelerometer (Actigraph, Pensacola, FL, USA) for 14 days and completed the UVR diary app. Data from the UVR diary app were compared with UVR dosimeter wristwatch, accelerometer, and paper UVR diary data. Cohen kappa coefficient score was used to determine if there was agreement between categorical variables for different UVR data collection methods and Spearman rank correlation coefficient was used to determine agreement between continuous accelerometer data and app-collected self-report physical activity. Results The mean age of participants in Groups A (n=19) and B (n=55) was 29.3 and 25.4 years, and 63% (12/19) and 75% (41/55) were females, respectively. Self-reported sun exposure data in the UVR app correlated highly with UVR dosimetry (κ=0.83, 95% CI 0.64-1.00, P<.001). Correlation between self-reported UVR app and accelerometer-collected moderate to vigorous physical activity data was low (ρ=0.23, P=.10), while agreement for low-intensity physical activity was significantly different (ρ=-0.49, P<.001). Seventy-nine percent of participants preferred the app over the paper diary for daily self-report of UVR exposure and physical activity. Conclusions This feasibility study highlights self-report using an UVR app can reliably collect personal UVR exposure, but further improvements are required before the app can also be used to collect physical activity data. PMID:29666044

  17. Making the cut: Depression screening in urban general hospital clinics for culturally diverse Latino populations.

    PubMed

    Gutnick, Damara; Siegel, Carole; Laska, Eugene; Wanderling, Joseph; Wagner, Ellen Cogen; Haugland, Gary; Conlon, Mary K

    We examined whether the cut-point 10 for the Patient Health Questionnaire-9 (PHQ9) depression screen used in primary care populations is equally valid for Mexicans (M), Ecuadorians (E), Puerto Ricans (PR) and non-Hispanic whites (W) from inner-city hospital-based primary care clinics; and whether stressful life events elevate scores and the probability of major depressive disorder (MDD). Over 18-months, a sample of persons from hospital clinics with a positive initial PHQ2 and a subsequent PHQ9 were administered a stressful life event questionnaire and a Structured Clinical Interview to establish an MDD diagnosis, with oversampling of those between 8 and 12: (n=261: 75 E, 71 M, 51 PR, 64 W). For analysis, the sample was weighted using chart review (n=368) to represent a typical clinic population. Receiver Operating Characteristics analysis selected cut-points maximizing sensitivity (Sn) plus specificity (Sp). The optimal cut-point for all groups was 13 with the corresponding Sn and Sp estimates for E=(Sn 73%, Sp 71%), M=(76%, 81%), PR=(81%, 63%) and W=(80%, 74%). Stressful life events impacted screen scores and MDD diagnosis. Elevating the PHQ9 cut-point for inner-city Latinos as well as whites is suggested to avoid high false positive rates leading to improper treatment with clinical and economic consequences. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Traumatic brain injury: It is all about definition.

    PubMed

    Savitsky, B; Givon, A; Rozenfeld, M; Radomislensky, I; Peleg, K

    2016-01-01

    TBI may be defined by different methods. Some may be most useful for immediate clinical purposes, however less optimal for epidemiologic research. Other methods, such as the Abbreviated Injury Score (AIS), may prove more beneficial for this task, if the cut-off-points for their categories are defined correctly. To reveal the optimal cut-off-points for AIS in definition of severity of TBI in order to ensure uniformity between future studies of TBI. Mortality of patients with TBI AIS 3, 4 was 1.9% and 2.9% respectively, comparing with 31.1% among TBI AIS 5+. Predictive discrimination ability of the model with cut-off-points of 5+ for TBI AIS (in comparison with other cut-off-points) was better. Patients with missing Glasgow Coma Scale (GCS) in the ED had an in-hospital mortality rate of 11.5%. In this group, 25% had critical TBI according to AIS. Normal GCS didn't indicate an absence of head injury, as, among patients with GCS 15 in the ED, 26% had serious/critical TBI injury. Moreover, 7% of patients with multiple injury and GCS 3-8 had another reason than head injury for unconsciousness. This study recommends the adoption of an AIS cut-off ≥ 5 as a valid definition of severe TBI in epidemiological studies, while AIS 3-4 may be defined as 'moderate' TBI and AIS 1-2 as 'mild'.

  19. Using the GOCE star trackers for validating the calibration of its accelerometers

    NASA Astrophysics Data System (ADS)

    Visser, P. N. A. M.

    2017-12-01

    A method for validating the calibration parameters of the six accelerometers on board the Gravity field and steady-state Ocean Circulation Explorer (GOCE) from star tracker observations that was originally tested by an end-to-end simulation, has been updated and applied to real data from GOCE. It is shown that the method provides estimates of scale factors for all three axes of the six GOCE accelerometers that are consistent at a level significantly better than 0.01 compared to the a priori calibrated value of 1. In addition, relative accelerometer biases and drift terms were estimated consistent with values obtained by precise orbit determination, where the first GOCE accelerometer served as reference. The calibration results clearly reveal the different behavior of the sensitive and less-sensitive accelerometer axes.

  20. Associations between Patterns of Objectively Measured Physical Activity and Risk Factors for the Metabolic Syndrome

    PubMed Central

    Metzger, Jesse S.; Catellier, Diane J.; Evenson, Kelly R.; Treuth, Margarita S.; Rosamond, Wayne D.; Siega-Riz, Anna Maria

    2017-01-01

    Purpose Determine whether certain patterns of objectively measured physical activity (PA) are associated with the risk factors for or the diagnosis of the metabolic syndrome (MS). Design Latent class analysis, including the assessment of the associations between latent PA classes and the risk factors for MS. Setting Random sample from throughout the United States (US) using data from 2003–2004 National Health and Nutrition Examination Survey. Subjects A total of 3,458 adult, civilian, non-institutionalized US citizens. Measures Daily minutes of moderate-to-vigorous PA across a 7-day week, based on accelerometer measurements, as well ashigh blood pressure, blood glucose levels, triglyceride levels, and body mass index, along with low levels of high density lipoproteins, using clinical cut points. Results Membership in the more active PA classes was consistently associated with lower odds of all of the risk factors for the MS. However, when participants were categorized into quartiles of the coefficient of variation of PA across 7 days, few differences were seen in any of the risk factors. Conclusion Accumulating the total recommended amount of PA for a week is consistently associated with positive health profiles, and more PA than the recommended amounts may suggest. However, the manner in which this activity is accumulated, either spread over most days of the week or compressed into just a couple of days, may have similar associations with the risk factors for the MS. PMID:20073381

  1. Fractional Flow Reserve: Does a Cut-off Value add Value?

    PubMed Central

    Mohdnazri, Shah R; Keeble, Thomas R

    2016-01-01

    Fractional flow reserve (FFR) has been shown to improve outcomes when used to guide percutaneous coronary intervention (PCI). There have been two proposed cut-off points for FFR. The first was derived by comparing FFR against a series of non-invasive tests, with a value of ≤0.75 shown to predict a positive ischaemia test. It was then shown in the DEFER study that a vessel FFR value of ≥0.75 was associated with safe deferral of PCI. During the validation phase, a ‘grey zone’ for FFR values of between 0.76 and 0.80 was demonstrated, where a positive non-invasive test may still occur, but sensitivity and specificity were sub-optimal. Clinical judgement was therefore advised for values in this range. The FAME studies then moved the FFR cut-off point to ≤0.80, with a view to predicting outcomes. The ≤0.80 cut-off point has been adopted into clinical practice guidelines, whereas the lower value of ≤0.75 is no longer widely used. Here, the authors discuss the data underpinning these cut-off values and the practical implications for their use when using FFR guidance in PCI. PMID:29588700

  2. On determining the most appropriate test cut-off value: the case of tests with continuous results

    PubMed Central

    Habibzadeh, Parham; Yadollahie, Mahboobeh

    2016-01-01

    There are several criteria for determination of the most appropriate cut-off value in a diagnostic test with continuous results. Mostly based on receiver operating characteristic (ROC) analysis, there are various methods to determine the test cut-off value. The most common criteria are the point on ROC curve where the sensitivity and specificity of the test are equal; the point on the curve with minimum distance from the left-upper corner of the unit square; and the point where the Youden’s index is maximum. There are also methods mainly based on Bayesian decision analysis. Herein, we show that a proposed method that maximizes the weighted number needed to misdiagnose, an index of diagnostic test effectiveness we previously proposed, is the most appropriate technique compared to the aforementioned ones. For determination of the cut-off value, we need to know the pretest probability of the disease of interest as well as the costs incurred by misdiagnosis. This means that even for a certain diagnostic test, the cut-off value is not universal and should be determined for each region and for each disease condition. PMID:27812299

  3. Critical analysis of forensic cut-offs and legal thresholds: A coherent approach to inference and decision.

    PubMed

    Biedermann, A; Taroni, F; Bozza, S; Augsburger, M; Aitken, C G G

    2018-07-01

    In this paper we critically discuss the definition and use of cut-off values by forensic scientists, for example in forensic toxicology, and point out when and why such values - and ensuing categorical conclusions - are inappropriate concepts for helping recipients of expert information with their questions of interest. Broadly speaking, a cut-off is a particular value of results of analyses of a target substance (e.g., a toxic substance or one of its metabolites in biological sample from a person of interest), defined in a way such as to enable scientists to suggest conclusions regarding the condition of the person of interest. The extent to which cut-offs can be reliably defined and used is not unanimously agreed within the forensic science community, though many practitioners - especially in operational laboratories - rely on cut-offs for reasons such as ease of use and simplicity. In our analysis, we challenge this practice by arguing that choices made for convenience should not be to the detriment of balance and coherence. To illustrate our discussion, we will choose the example of alcohol markers in hair, used widely by forensic toxicologists to reach conclusions regarding the drinking behaviour of individuals. Using real data from one of the co-authors' own work and recommendations of cut-offs published by relevant professional organisations, we will point out in what sense cut-offs are incompatible with current evaluative guidelines (e.g., [31]) and show how to proceed logically without cut-offs by using a standard measure for evidential value. Our conclusions run counter to much current practice, but are inevitable given the inherent definitional and conceptual shortcomings of scientific cut-offs. We will also point out the difference between scientific cut-offs and legal thresholds and argue that the latter - but not the former - are justifiable and can be dealt with in logical evaluative procedures. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Optimal cut-off points for waist circumference in the definition of metabolic syndrome in Brazilian adults: baseline analyses of the Longitudinal Study of Adult Health (ELSA-Brasil).

    PubMed

    Cardinal, Thiane Ristow; Vigo, Alvaro; Duncan, Bruce Bartholow; Matos, Sheila Maria Alvim; da Fonseca, Maria de Jesus Mendes; Barreto, Sandhi Maria; Schmidt, Maria Inês

    2018-01-01

    Waist circumference (WC) has been incorporated in the definition of the metabolic syndrome (MetS) but the exact WC cut-off points across populations are not clear. The Joint Interim Statement (JIS) suggested possible cut-offs to different populations and ethnic groups. However, the adequacy of these cut-offs to Brazilian adults has been scarcely investigated. The objective of the study is to evaluate possible WC thresholds to be used in the definition of MetS using data from the Longitudinal Study of Adult Health (ELSA-Brasil), a multicenter cohort study of civil servants (35-74 years old) of six Brazilian cities. We analyzed baseline data from 14,893 participants (6772 men and 8121 women). A MetS was defined according to the JIS criteria, but excluding WC and thus requiring 2 of the 4 remaining elements. We used restricted cubic spline regression to graph the relationship between WC and MetS. We identified optimal cut-off points which maximized joint sensitivity and specificity (Youden's index) from Receiver Operator Characteristic Curves. We also estimated the C-statistics using logistic regression. We found no apparent threshold for WC in restricted cubic spline plots. Optimal cut-off for men was 92 cm (2 cm lower than that recommended by JIS for Caucasian/Europids or Sub-Saharan African men), but 2 cm higher than that recommended for ethnic Central and South American. For women, optimal cut-off was 86, 6 cm higher than that recommended for Caucasian/Europids and ethnic Central and South American. Optimal cut-offs did not very across age groups and most common race/color categories (except for Asian men, 87 cm). Sex-specific cut-offs for WC recommended by JIS differ from optimal cut-offs we found for adult men and women of Brazil´s most common ethnic groups.

  5. Vision-Aided Autonomous Precision Weapon Terminal Guidance Using a Tightly-Coupled INS and Predictive Rendering Techniques

    DTIC Science & Technology

    2011-03-01

    b b are additive accelerometer and gyro noises and w b abias and wbbbias are accelerometer bias and gyro bias noises. These will described in further...order accelerometer bias time constant and w b abias is the additive accelerometer bias noise, and ḃb = − 1 τb bb +wbbbias (2.43) where τb is the first

  6. Automatic machine-learning based identification of jogging periods from accelerometer measurements of adolescents under field conditions.

    PubMed

    Zdravevski, Eftim; Risteska Stojkoska, Biljana; Standl, Marie; Schulz, Holger

    2017-01-01

    Assessment of health benefits associated with physical activity depend on the activity duration, intensity and frequency, therefore their correct identification is very valuable and important in epidemiological and clinical studies. The aims of this study are: to develop an algorithm for automatic identification of intended jogging periods; and to assess whether the identification performance is improved when using two accelerometers at the hip and ankle, compared to when using only one at either position. The study used diarized jogging periods and the corresponding accelerometer data from thirty-nine, 15-year-old adolescents, collected under field conditions, as part of the GINIplus study. The data was obtained from two accelerometers placed at the hip and ankle. Automated feature engineering technique was performed to extract features from the raw accelerometer readings and to select a subset of the most significant features. Four machine learning algorithms were used for classification: Logistic regression, Support Vector Machines, Random Forest and Extremely Randomized Trees. Classification was performed using only data from the hip accelerometer, using only data from ankle accelerometer and using data from both accelerometers. The reported jogging periods were verified by visual inspection and used as golden standard. After the feature selection and tuning of the classification algorithms, all options provided a classification accuracy of at least 0.99, independent of the applied segmentation strategy with sliding windows of either 60s or 180s. The best matching ratio, i.e. the length of correctly identified jogging periods related to the total time including the missed ones, was up to 0.875. It could be additionally improved up to 0.967 by application of post-classification rules, which considered the duration of breaks and jogging periods. There was no obvious benefit of using two accelerometers, rather almost the same performance could be achieved from either accelerometer position. Machine learning techniques can be used for automatic activity recognition, as they provide very accurate activity recognition, significantly more accurate than when keeping a diary. Identification of jogging periods in adolescents can be performed using only one accelerometer. Performance-wise there is no significant benefit from using accelerometers on both locations.

  7. Validity, cut-points, and minimally important differences for two hot flash-related daily interference scales.

    PubMed

    Carpenter, Janet S; Bakoyannis, Giorgos; Otte, Julie L; Chen, Chen X; Rand, Kevin L; Woods, Nancy; Newton, Katherine; Joffe, Hadine; Manson, JoAnn E; Freeman, Ellen W; Guthrie, Katherine A

    2017-08-01

    To conduct psychometric analyses to condense the Hot Flash-Related Daily Interference Scale (HFRDIS) into a shorter form termed the Hot Flash Interference (HFI) scale; evaluate cut-points for both scales; and establish minimally important differences (MIDs) for both scales. We analyzed baseline and postrandomization patient-reported data pooled across three randomized trials aimed at reducing vasomotor symptoms (VMS) in 899 midlife women. Trials were conducted across five MsFLASH clinical sites between July 2009 and October 2012. We eliminated HFRDIS items based on experts' content validity ratings and confirmatory factor analysis, and evaluated cut-points and established MIDs by mapping HFRDIS and HFI to other measures. The three-item HFI (interference with sleep, mood, and concentration) demonstrated strong internal consistency (alphas of 0.830 and 0.856), showed good fit to the unidimensional "hot flash interference factor," and strong convergent validity with HFRDIS scores, diary VMS, and menopausal quality of life. For both scales, cut-points of mild (0-3.9), moderate (4-6.9), and severe (7-10) interference were associated with increasing diary VMS ratings, sleep, and anxiety. The average MID was 1.66 for the HFRDIS and 2.34 for the HFI. The HFI is a brief assessment of VMS interference and will be useful in busy clinics to standardize VMS assessment or in research studies where response burden may be an issue. The scale cut-points and MIDs should prove useful in targeting those most in need of treatment, monitoring treatment response, and interpreting existing and future research findings.

  8. Using open source accelerometer analysis to assess physical activity and sedentary behaviour in overweight and obese adults.

    PubMed

    Innerd, Paul; Harrison, Rory; Coulson, Morc

    2018-04-23

    Physical activity and sedentary behaviour are difficult to assess in overweight and obese adults. However, the use of open-source, raw accelerometer data analysis could overcome this. This study compared raw accelerometer and questionnaire-assessed moderate-to-vigorous physical activity (MVPA), walking and sedentary behaviour in normal, overweight and obese adults, and determined the effect of using different methods to categorise overweight and obesity, namely body mass index (BMI), bioelectrical impedance analysis (BIA) and waist-to-hip ratio (WHR). One hundred twenty adults, aged 24-60 years, wore a raw, tri-axial accelerometer (Actigraph GT3X+), for 3 days and completed a physical activity questionnaire (IPAQ-S). We used open-source accelerometer analyses to estimate MVPA, walking and sedentary behaviour from a single raw accelerometer signal. Accelerometer and questionnaire-assessed measures were compared in normal, overweight and obese adults categorised using BMI, BIA and WHR. Relationships between accelerometer and questionnaire-assessed MVPA (Rs = 0.30 to 0.48) and walking (Rs = 0.43 to 0.58) were stronger in normal and overweight groups whilst sedentary behaviour were modest (Rs = 0.22 to 0.38) in normal, overweight and obese groups. The use of WHR resulted in stronger agreement between the questionnaire and accelerometer than BMI and BIA. Finally, accelerometer data showed stronger associations with BMI, BIA and WHR (Rs = 0.40 to 0.77) than questionnaire data (Rs = 0.24 to 0.37). Open-source, raw accelerometer data analysis can be used to estimate MVPA, walking and sedentary behaviour from a single acceleration signal in normal, overweight and obese adults. Our data supports the use of WHR to categorise overweight and obese adults. This evidence helps researchers obtain more accurate measures of physical activity and sedentary behaviour in overweight and obese populations.

  9. Pretinning Nickel-Plated Wire Shields

    NASA Technical Reports Server (NTRS)

    Igawa, J. A.

    1985-01-01

    Nickel-plated copper shielding for wires pretinned for subsequent soldering with help of activated rosin flux. Shield cut at point 0.25 to 0.375 in. (6 to 10 mm) from cut end of outer jacket. Loosened end of shield straightened and pulled toward cut end. Insulation of inner wires kept intact during pretinning.

  10. Comparison of self-reported versus accelerometer-measured physical activity.

    PubMed

    Dyrstad, Sindre M; Hansen, Bjørge H; Holme, Ingar M; Anderssen, Sigmund A

    2014-01-01

    The International Physical Activity Questionnaire (IPAQ) is one of the most widely used questionnaires to assess physical activity (PA). Validation studies for the IPAQ have been executed, but still there is a need for studies comparing absolute values between IPAQ and accelerometer in large population studies. To compare PA and sedentary time from the self-administered, short version of the IPAQ with data from ActiGraph accelerometer in a large national sample. A total of 1751 adults (19-84 yr) wore an accelerometer (ActiGraph GT1M) for seven consecutive days and completed the IPAQ-Short Form. Sedentary time, total PA, and time spent in moderate to vigorous activity were compared in relation to sex, age, and education. Men and women reported, on average, 131 min·d (SE = 4 min·d) less sedentary time compared with the accelerometer measurements. The difference between self-reported and measured sedentary time and vigorous-intensity PA was greatest among men with a lower education level and for men 65 yr and older. Although men reported 47% more moderate to vigorous physical activity (MVPA) compared with women, there were no differences between sexes in accelerometer-determined MVPA. Accelerometer-determined moderate PA was reduced from 110 to 42 min·d (62%) when analyzed in blocks of 10 min (P < 0.0001) compared with 1-min blocks. The main correlation coefficients between self-reported variables and accelerometer measures of physical activity were between 0.20 and 0.46. The participants report through IPAQ-Short Form more vigorous PA and less sedentary time compared with the accelerometer. The difference between self-reported and accelerometer-measured MVPA increased with higher activity and intensity levels. Associations between the methods were affected by sex, age, and education, but not body mass index.

  11. Detecting depression among adolescents in Santiago, Chile: sex differences.

    PubMed

    Araya, Ricardo; Montero-Marin, Jesus; Barroilhet, Sergio; Fritsch, Rosemarie; Gaete, Jorge; Montgomery, Alan

    2013-04-23

    Depression among adolescents is common but most cases go undetected. Brief questionnaires offer an opportunity to identify probable cases but properly validated cut-off points are often unavailable, especially in non-western countries. Sex differences in the prevalence of depression become marked in adolescence and this needs to be accounted when establishing cut-off points. This study involved adolescents attending secondary state schools in Santiago, Chile. We compared the self-reported Beck Depression Inventory-II with a psychiatric interview to ascertain diagnosis. General psychometric features were estimated before establishing the criterion validity of the BDI-II. The BDI-II showed good psychometric properties with good internal consistency, a clear unidimensional factorial structure, and good capacity to discriminate between cases and non-cases of depression. Optimal cut-off points to establish caseness for depression were much higher for girls than boys. Sex discrepancies were primarily explained by differences in scores among those with depression rather than among those without depression. It is essential to validate scales with the populations intended to be used with. Sex differences are often ignored when applying cut-off points, leading to substantial misclassification. Early detection of depression is essential if we think that early intervention is a clinically important goal.

  12. Wearable Accelerometers in High Performance Jet Aircraft.

    PubMed

    Rice, G Merrill; VanBrunt, Thomas B; Snider, Dallas H; Hoyt, Robert E

    2016-02-01

    Wearable accelerometers have become ubiquitous in the fields of exercise physiology and ambulatory hospital settings. However, these devices have yet to be validated in extreme operational environments. The objective of this study was to correlate the gravitational forces (G forces) detected by wearable accelerometers with the G forces detected by high performance aircraft. We compared the in-flight G forces detected by the two commercially available portable accelerometers to the F/A-18 Carrier Aircraft Inertial Navigation System (CAINS-2) during 20 flights performed by the Navy's Flight Demonstration Squadron (Blue Angels). Postflight questionnaires were also used to assess the perception of distractibility during flight. Of the 20 flights analyzed, 10 complete in-flight comparisons were made, accounting for 25,700 s of correlation between the CAINS-2 and the two tested accelerometers. Both accelerometers had strong correlations with that of the F/A-18 Gz axis, averaging r = 0.92 and r = 0.93, respectively, over 10 flights. Comparison of both portable accelerometer's average vector magnitude to each other yielded an average correlation of r = 0.93. Both accelerometers were found to be minimally distracting. These results suggest the use of wearable accelerometers is a valid means of detecting G forces during high performance aircraft flight. Future studies using this surrogate method of detecting accelerative forces combined with physiological information may yield valuable in-flight normative data that heretofore has been technically difficult to obtain and hence holds the promise of opening the door for a new golden age of aeromedical research.

  13. Accelerometer profiles of physical activity and inactivity in normal weight, overweight, and obese U.S. men and women.

    PubMed

    Tudor-Locke, Catrine; Brashear, Meghan M; Johnson, William D; Katzmarzyk, Peter T

    2010-08-03

    The 2005-2006 National Health and Nutrition Examination Survey (NHANES) is used to describe an accelerometer-derived physical activity/inactivity profile in normal weight (BMI < 25 kg/m2), overweight (25 /= 30 kg/m2) U.S. adults. We computed physical activity volume indicators (activity counts/day, uncensored and censored steps/day), rate indicators (e.g., steps/minute), time indicators (employing NHANES activity counts/minute cut points to infer time in non-wear, sedentary, low, light, moderate, and vigorous intensities), the number of breaks in sedentary time (occasions when activity counts rose from < 100 activity/counts in one minute to >/= 100 activity counts in the subsequent minute), achievement of public health guidelines, and classification by step-defined physical activity levels. Data were examined for evidence of consistent and significant gradients across BMI-defined categories. In 2005-2006, U.S adults averaged 6,564 +/- SE 107 censored steps/day, and after considering non-wear time, they spent approximately 56.8% of the rest of the waking day in sedentary time, 23.7% in low intensity, 16.7% in light intensity, 2.6% in moderate intensity, and 0.2% in vigorous intensity. Overall, approximately 3.2% of U.S. adults achieved public health guidelines. The normal weight category took 7,190 +/- SE 157 steps/day, and spent 25.7 +/- 0.9 minutes/day in moderate intensity and 7.3 +/- 0.4 minutes/day in vigorous intensity physical activity. The corresponding numbers for the overweight category were 6,879 +/- 140 steps/day, 25.3 +/- 0.9 minutes/day, and 5.3 +/- 0.5 minutes/day and for the obese category 5,784 +/- 124 steps/day, 17.3 +/- 0.7 minutes/day and 3.2 +/- 0.4 minutes/day. Across BMI categories, increasing gradients and significant trends were apparent in males for sedentary time and decreasing gradients and significant trends were evident in time spent in light intensity, moderate intensity, and vigorous intensity. For females, there were only consistent gradients and significant trends apparent for decreasing amounts of time spent in moderate and vigorous intensity. Simple indicators of physical activity volume (i.e., steps/day) and time in light, moderate or vigorous intensity physical activity differ across BMI categories for both sexes, suggesting that these should continue to be targets for surveillance.

  14. Validation of Physical Activity Tracking via Android Smartphones Compared to ActiGraph Accelerometer: Laboratory-Based and Free-Living Validation Studies.

    PubMed

    Hekler, Eric B; Buman, Matthew P; Grieco, Lauren; Rosenberger, Mary; Winter, Sandra J; Haskell, William; King, Abby C

    2015-04-15

    There is increasing interest in using smartphones as stand-alone physical activity monitors via their built-in accelerometers, but there is presently limited data on the validity of this approach. The purpose of this work was to determine the validity and reliability of 3 Android smartphones for measuring physical activity among midlife and older adults. A laboratory (study 1) and a free-living (study 2) protocol were conducted. In study 1, individuals engaged in prescribed activities including sedentary (eg, sitting), light (sweeping), moderate (eg, walking 3 mph on a treadmill), and vigorous (eg, jogging 5 mph on a treadmill) activity over a 2-hour period wearing both an ActiGraph and 3 Android smartphones (ie, HTC MyTouch, Google Nexus One, and Motorola Cliq). In the free-living study, individuals engaged in usual daily activities over 7 days while wearing an Android smartphone (Google Nexus One) and an ActiGraph. Study 1 included 15 participants (age: mean 55.5, SD 6.6 years; women: 56%, 8/15). Correlations between the ActiGraph and the 3 phones were strong to very strong (ρ=.77-.82). Further, after excluding bicycling and standing, cut-point derived classifications of activities yielded a high percentage of activities classified correctly according to intensity level (eg, 78%-91% by phone) that were similar to the ActiGraph's percent correctly classified (ie, 91%). Study 2 included 23 participants (age: mean 57.0, SD 6.4 years; women: 74%, 17/23). Within the free-living context, results suggested a moderate correlation (ie, ρ=.59, P<.001) between the raw ActiGraph counts/minute and the phone's raw counts/minute and a strong correlation on minutes of moderate-to-vigorous physical activity (MVPA; ie, ρ=.67, P<.001). Results from Bland-Altman plots suggested close mean absolute estimates of sedentary (mean difference=-26 min/day of sedentary behavior) and MVPA (mean difference=-1.3 min/day of MVPA) although there was large variation. Overall, results suggest that an Android smartphone can provide comparable estimates of physical activity to an ActiGraph in both a laboratory-based and free-living context for estimating sedentary and MVPA and that different Android smartphones may reliably confer similar estimates.

  15. A simple 5-point scoring system, NaURSE (Na+, urea, respiratory rate and shock index in the elderly), predicts in-hospital mortality in oldest old.

    PubMed

    Wilson, Alexander H; Kidd, Andrew C; Skinner, Jane; Musonda, Patrick; Pai, Yogish; Lunt, Claire J; Butchart, Catherine; Soiza, Roy L; Potter, John F; Myint, Phyo Kyaw

    2014-05-01

    the mortality is high in acutely ill oldest old patients. Understanding the prognostic factors which influence mortality will help clinicians make appropriate management decisions. we analysed prospective mortality audit data (November 2008 to January 2009) to identify variables associated with in-patient mortality in oldest old. We selected those with P < 0.10 from univariate analysis and determined at which cut-point they served as the strongest predictor of mortality. Using these cut-off points, we constructed multivariate logistic regression models. A 5-point score was derived from cut-off points which were significantly associated with mortality tested in a smaller independent re-audit sample conducted in October 2011. a total of 405 patients (mean 93.5 ± 2.7 years) were included in the study. The mean length of stay was 18.5 ± 42.4 days and 13.8% died as in-patients. Variables (cut-off values) found to be significantly associated with in-patient mortality were admission sodium (>145 mmol/l), urea (≥14 mmol/l), respiratory rate (>20/min) and shock index (>1.0): creating a 5-point score (NaURSE: NaURS in the Elderly). The crude mortality rates were 9.5, 19.9, 34.4, 66.7, and 100% for scores 0, 1, 2, 3 and 4, respectively. Using the cut-off point of ≥2, the NaURSE score has a specificity of 87% (83.1-90.3) and sensitivity of 39% (28.5-50.0), with an AUC value of 0.69 (0.63-0.76). An external independent validation study (n = 121) showed similar results. the NaURSE score may be particularly useful in identifying oldest old who are likely to die in that admission to guide appropriate care.

  16. Low-Frequency Foam Insulator (LOFFI) Accelerometer Mount Characterization Results and Analysis for Phase I (FY2013)

    DTIC Science & Technology

    2014-06-01

    Low-Frequency Foam Insulator (LOFFI) Accelerometer Mount Characterization Results and Analysis for Phase I (FY2013) by Andrew Drysdale...Proving Ground, MD 21005-5068 ARL-TR-6977 June 2014 Low-Frequency Foam Insulator (LOFFI) Accelerometer Mount Characterization Results...4. TITLE AND SUBTITLE Low-Frequency Foam Insulator (LOFFI) Accelerometer Mount Characterization Results and Analysis for Phase I (FY2013) 5a

  17. Waist circumference cut-off points for identification of abdominal obesity among the tunisian adult population.

    PubMed

    Bouguerra, R; Alberti, H; Smida, H; Salem, L B; Rayana, C B; El Atti, J; Achour, A; Gaigi, S; Slama, C B; Zouari, B; Alberti, K G M M

    2007-11-01

    Waist circumference (WC) is a convenient measure of abdominal adipose tissue. It itself is a cardiovascular disease (CVD) and diabetes-risk factor and is strongly linked to other CVD risk factors. There are, however, ethnic differences in the relationship of WC to the other risk factors. The aim of this study was to determine the optimal cut-off points of WC and body mass index (BMI) at which cardiovascular risk factors can be identified with maximum sensitivity and specificity in a representative sample of the Tunisian adult population and to investigate any correlation between WC and BMI. We used a sample of the Tunisian National Nutrition Survey, a cross-sectional population-based survey, conducted in 1996 on a large nationally representative sample, which included 3435 adults (1244 men and 2191 women) of 20 years or older. WC, BMI, blood pressure and fasting blood measurements (plasma glucose, total cholesterol, triglycerides) were recorded. Receiver operating characteristic (ROC) curve analysis was used to identify optimal cut-off values of WC and BMI to identify with maximum sensitivity and specificity the detection of high blood pressure, hyperglycaemia, high blood cholesterol and hypertriglyceridaemia. ROC curve analysis suggested WC cut-off points of 85 cm in men and 85 cm in women for the optimum detection of high blood pressure, diabetes and dyslipidaemia. The optimum BMI cut-off points for predicting cardiovascular risk factors were 24 kg/m(2) in men and 27 kg/m(2) in women. The cut-off points recommended for the Caucasian population differ from those appropriate for the Tunisian population. The data show a continuous increase in odds ratios of each cardiovascular risk factor, with increasing level of WC and BMI. WC exceeding 85 cm in men and 79 cm in women correctly identified subjects with a BMI of >/=25 kg/m(2), sensitivity of >90% and specificity of >83%. Based on the ROC analysis, we suggest a WC of 85 cm for both men and women as appropriate cut-off points to identify central obesity for the purposes of CVD and diabetes-risk detection among Tunisians. WCs of 85 cm in men and 79 cm in women were the most sensitive and specific to identify most subjects with a BMI >/=25 kg/m(2).

  18. Implementation of Steiner point of fuzzy set.

    PubMed

    Liang, Jiuzhen; Wang, Dejiang

    2014-01-01

    This paper deals with the implementation of Steiner point of fuzzy set. Some definitions and properties of Steiner point are investigated and extended to fuzzy set. This paper focuses on establishing efficient methods to compute Steiner point of fuzzy set. Two strategies of computing Steiner point of fuzzy set are proposed. One is called linear combination of Steiner points computed by a series of crisp α-cut sets of the fuzzy set. The other is an approximate method, which is trying to find the optimal α-cut set approaching the fuzzy set. Stability analysis of Steiner point of fuzzy set is also studied. Some experiments on image processing are given, in which the two methods are applied for implementing Steiner point of fuzzy image, and both strategies show their own advantages in computing Steiner point of fuzzy set.

  19. Structural health monitoring using a hybrid network of self-powered accelerometer and strain sensors

    NASA Astrophysics Data System (ADS)

    Alavi, Amir H.; Hasni, Hassene; Jiao, Pengcheng; Lajnef, Nizar

    2017-04-01

    This paper presents a structural damage identification approach based on the analysis of the data from a hybrid network of self-powered accelerometer and strain sensors. Numerical and experimental studies are conducted on a plate with bolted connections to verify the method. Piezoelectric ceramic Lead Zirconate Titanate (PZT)-5A ceramic discs and PZT-5H bimorph accelerometers are placed on the surface of the plate to measure the voltage changes due to damage progression. Damage is defined by loosening or removing one bolt at a time from the plate. The results show that the PZT accelerometers provide a fairly more consistent behavior than the PZT strain sensors. While some of the PZT strain sensors are not sensitive to the changes of the boundary condition, the bimorph accelerometers capture the mode changes from undamaged to missing bolt conditions. The results corresponding to the strain sensors are better indicator to the location of damage compared to the accelerometers. The characteristics of the overall structure can be monitored with even one accelerometer. On the other hand, several PZT strain sensors might be needed to localize the damage.

  20. [The Alvarado score validation in diagnosing acute appendicitis in children at Braga Hospital].

    PubMed

    Gonçalves, Jean Pierre; Cerqueira, Arnaldo; Martins, Sofia

    2011-12-01

    Acute appendicitis (AA) is the leading cause of emergency abdominal surgery in children. The diagnosis is essentially clinical, but some methodologies, such as Alvarado score (AS), have been developed in order to avoid non-therapeutic laparotomy (15-30%). AS ≥ 5 or 6 is compatible with AA and is an indication for the patient to remain on observations, if AS ≥ 7 a laparotomy procedure may be indicated. To validate the AS for the AA diagnosis of children admitted at Braga Hospital. A validation study of diagnostic method (AS) using the histological examination as a gold standard. The study population consisted of 192 children (4-17 years) with abdominal pain that underwent appendectomy in the last 20 months (December 2008 to July 2010). It was determined the values of sensitivity (S), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), likelihood ratio (LR) and the ROC curve for three different cut-off points (SA =5, 6 and 7). We found that as the cut-off point of AS decreases progressively the sensitivity and specificity increases and reduces the VPN and VPP. Assuming a cut-off value of 5, only 18 children would be false negatives, instead of the 67 children if the cut-off point was 7 points. The analysis of ROC curves demonstrated a greater area under the curve for a cut-off equal to or greater than 5 (AUC = 70%). We recommend using a cut-off value of 5 points, since only 18 children with AA were initially classified as appendicitis unlikely, this value would increase to 67 patients for the SA value of ≥ 7. The AS is a valuable tool in screening children with abdominal pain for the diagnosis of AA. Nonetheless the diagnosis and final decision must be based on clinical and systematic reassessment of patients.

  1. Estimating the Heading Direction Using Normal Flow

    DTIC Science & Technology

    1994-01-01

    understood (Faugeras and Maybank 1990), 3 Kinetic Stabilization under the assumption that optic flow or correspon- dence is known with some uncertainty...accelerometers can achieve very It can easily be shown (Koenderink and van Doom high accuracy, the same is not true for inexpensive 1975; Maybank 1985... Maybank . ’Motion from point matches: Multi- just don’t compute normal flow there (see Section 6). plicity of solutions". Int’l J. Computer Vision 4

  2. Occupant Motion Sensors : Development and Testing of Piezoresistive Mouthpiece Rotational Accelerometer

    DOT National Transportation Integrated Search

    1973-07-01

    A miniature piezoresistive mouthpiece rotational accelerometer has been developed to measure the angular acceleration of a head during a simulated vehicle crash. Corrections have been electronically applied to the rotational accelerometer to reduce i...

  3. Locations of Joint Physical Activity in Parent-Child Pairs Based on Accelerometer and GPS Monitoring

    PubMed Central

    Dunton, Genevieve Fridlund; Liao, Yue; Almanza, Estela; Jerrett, Micheal; Spruijt-Metz, Donna; Pentz, Mary Ann

    2012-01-01

    Background Parental factors may play an important role in influencing children’s physical activity levels. Purpose This cross-sectional study sought to describe the locations of joint physical activity among parents and children. Methods Parent-child pairs (N = 291) wore an Actigraph GT2M accelerometer and GlobalSat BT-335 Global Positioning Systems (GPS) device over the same 7-day period. Children were ages 8–14 years. Joint behavior was defined by a linear separation distance of less than 50m between parent and child. Land use classifications were assigned to GPS data points. Results Joint physical activity was spread across residential locations (35%), and commercial venues (24%), and open spaces/parks (20%). Obese children and parents performed less joint physical activity in open spaces/parks than under/normal weight children and parents (p’s < .01). Conclusions Understanding where joint parent-child physical activity naturally occurs may inform location-based interventions to promote these behaviors. PMID:23011914

  4. Satellite borne gravity gradiometer study

    NASA Technical Reports Server (NTRS)

    Metzger, E.; Jircitano, A.; Affleck, C.

    1976-01-01

    Gravity gradiometry is recognized to be a very difficult instrumentation problem because extremely small differential acceleration levels have to be measured, 0.1 EU corresponds to an acceleration of 10 to the minus 11th power g at two points 1 meter apart. A feasibility model of a gravity gradiometer is being developed for airborne applications using four modified versions of the proven Model VII accelerometers mounted on a slowly rotating fixture. Gravity gradients are being measured to 1.07 EU in a vertical rotation axis orientation. Equally significant are the outstanding operational characteristics such as fast reaction time, low temperature coefficients and high degree of bias stability over long periods of time. The rotating accelerometer gravity gradiometer approach and its present status is discussed and it is the foundation for the orbital gravity gradiometer analyzed. The performance levels achieved in a 1 g environment of the earth and under relatively high seismic disturbances, lend the orbital gravity gradiometer a high confidence level of success.

  5. Ground Vibration Attenuation Measurement using Triaxial and Single Axis Accelerometers

    NASA Astrophysics Data System (ADS)

    Mohammad, A. H.; Yusoff, N. A.; Madun, A.; Tajudin, S. A. A.; Zahari, M. N. H.; Chik, T. N. T.; Rahman, N. A.; Annuar, Y. M. N.

    2018-04-01

    Peak Particle Velocity is one of the important term to show the level of the vibration amplitude especially traveling wave by distance. Vibration measurement using triaxial accelerometer is needed to obtain accurate value of PPV however limited by the size and the available channel of the data acquisition module for detailed measurement. In this paper, an attempt to estimate accurate PPV has been made by using only a triaxial accelerometer together with multiple single axis accelerometer for the ground vibration measurement. A field test was conducted on soft ground using nine single axis accelerometers and a triaxial accelerometer installed at nine receiver location R1 to R9. Based from the obtained result, the method shows convincing similarity between actual PPV with the calculated PPV with error ratio 0.97. With the design method, vibration measurement equipment size can be reduced with fewer channel required.

  6. Systems and Methods for Determining Inertial Navigation System Faults

    NASA Technical Reports Server (NTRS)

    Bharadwaj, Raj Mohan (Inventor); Bageshwar, Vibhor L. (Inventor); Kim, Kyusung (Inventor)

    2017-01-01

    An inertial navigation system (INS) includes a primary inertial navigation system (INS) unit configured to receive accelerometer measurements from an accelerometer and angular velocity measurements from a gyroscope. The primary INS unit is further configured to receive global navigation satellite system (GNSS) signals from a GNSS sensor and to determine a first set of kinematic state vectors based on the accelerometer measurements, the angular velocity measurements, and the GNSS signals. The INS further includes a secondary INS unit configured to receive the accelerometer measurements and the angular velocity measurements and to determine a second set of kinematic state vectors of the vehicle based on the accelerometer measurements and the angular velocity measurements. A health management system is configured to compare the first set of kinematic state vectors and the second set of kinematic state vectors to determine faults associated with the accelerometer or the gyroscope based on the comparison.

  7. Statistical Considerations for Establishing CBTE Cut-Off Scores.

    ERIC Educational Resources Information Center

    Trzasko, Joseph A.

    This report gives the basic definition and purpose of competency-based teacher education (CBTE) cut-off scores. It describes the basic characteristics of CBTE as a yes-no dichotomous decision regarding the presence of a specific ability or knowledge, which necesitates the establishment of a cut-off point to designate competency vs. incompetency on…

  8. Technical note: Evaluation of digital refractometers to estimate serum immunoglobulin G concentration and passive transfer in Jersey calves.

    PubMed

    McCracken, M M; Morrill, K M; Fordyce, A L; Tyler, H D

    2017-10-01

    Previous data have demonstrated that refractometers can be used to estimate serum IgG, and that a cut-point of 7.8% Brix should be used to identify failure of passive transfer (FPT) in 1-d-old Holstein calves. The objective of the present study was to validate the use of refractometry to estimate serum IgG concentrations and evaluate FPT in Jersey calves. Blood samples (n = 97) were obtained from 1- to 3-d-old Jersey calves and centrifuged at 3,300 × g for 20 min at 25°C. Serum was analyzed for % Brix, total protein (TP), and refractive index (nD) using a Sper Scientific Digital Refractometer (model #300036, Sper Scientific, Scottsdale, AZ) within 12 h of sampling. Samples were then frozen and later analyzed in the laboratory for IgG by radial immunodiffusion. The mean serum IgG concentration for all calves was 23.7 mg/mL (SD = 12.5), with a range of 2.3 to 65.5 mg/mL. Mean serum % Brix was 8.9 (SD = 1.1; range 6.5 to 12.0). Serum % Brix was moderately correlated with IgG concentration (r = 0.77). Total protein and IgG were moderately correlated (r = 0.790). Regression was used to determine cut-points for approximately 10, 12, and 14 mg of IgG/mL and to determine the sensitivity and specificity of refractometry to identify FPT (serum IgG <10 mg/mL at 24 h of life). Brix cut-points analyzed were 7.1, 7.3, and 7.6%; TP cut-points were 4.6, 5.0, and 5.5 g/dL; and nD cut-points were 1.34332, 1.34271, and 1.3448, respectively, for 10, 12, and 14 mg of IgG/mL. The 7.3% Brix and 4.6 g/dL TP cut-points resulted in the greatest percentage of samples being correctly classified. These data suggest that digital refractometry is an acceptable and rapid method to estimate immunoglobulin G in Jersey calf serum. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  9. The Potential of Established Fitness Cut-off Points for Monitoring Women with Fibromyalgia: The al-Ándalus Project.

    PubMed

    Castro-Piñero, José; Aparicio, Virginia A; Estévez-López, Fernando; Álvarez-Gallardo, Inmaculada C; Borges-Cosic, Milkana; Soriano-Maldonado, Alberto; Delgado-Fernández, Manuel; Segura-Jiménez, Víctor

    2017-05-01

    The aim of the present study was to determinate whether fitness cut-off points discriminate the severity of major fibromyalgia symptoms and health-related quality of life. Additionally, we investigated which American Colleague of Rheumatology (ACR) fibromyalgia criteria (1990 vs. modified 2010) better discriminate fibromyalgia symptomatology. A total of 488 women with fibromyalgia and 200 non-fibromyalgia (control) women participated. All participants underwent both the 1990 and the modified 2010 ACR preliminary criteria (hereinafter 1990c and m-2010c, respectively). We used fitness cut-off points (Senior Fitness Tests Battery plus handgrip strength test) to discriminate between presence and absence of fibromyalgia. Additionally, we employed several instruments to assess fibromyalgia symptoms. Fitness cut-off points discriminated between high and low levels of the main symptoms the disease in all age groups (P from <0.001 to 0.01). Overall, the arm-curl and the 30-s chair stand tests presented the highest effect sizes in all symptoms, reinforcing the inclusion of fitness testing as a complementary tool for fibromyalgia diagnosis and monitoring. Moreover, the effect size of the differences in symptoms between women with fibromyalgia and controls were overall larger using the m-2010c compared with the 1990c, except for the tender points count, reflecting better the polysymptomatic distress condition of fibromyalgia. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Cut-off optimization for 13C-urea breath test in a community-based trial by mathematic, histology and serology approach.

    PubMed

    Li, Zhe-Xuan; Huang, Lei-Lei; Liu, Cong; Formichella, Luca; Zhang, Yang; Wang, Yu-Mei; Zhang, Lian; Ma, Jun-Ling; Liu, Wei-Dong; Ulm, Kurt; Wang, Jian-Xi; Zhang, Lei; Bajbouj, Monther; Li, Ming; Vieth, Michael; Quante, Michael; Zhou, Tong; Wang, Le-Hua; Suchanek, Stepan; Soutschek, Erwin; Schmid, Roland; Classen, Meinhard; You, Wei-Cheng; Gerhard, Markus; Pan, Kai-Feng

    2017-05-18

    The performance of diagnostic tests in intervention trials of Helicobacter pylori (H.pylori) eradication is crucial, since even minor inaccuracies can have major impact. To determine the cut-off point for 13 C-urea breath test ( 13 C-UBT) and to assess if it can be further optimized by serologic testing, mathematic modeling, histopathology and serologic validation were applied. A finite mixture model (FMM) was developed in 21,857 subjects, and an independent validation by modified Giemsa staining was conducted in 300 selected subjects. H.pylori status was determined using recomLine H.pylori assay in 2,113 subjects with a borderline 13 C-UBT results. The delta over baseline-value (DOB) of 3.8 was an optimal cut-off point by a FMM in modelling dataset, which was further validated as the most appropriate cut-off point by Giemsa staining (sensitivity = 94.53%, specificity = 92.93%). In the borderline population, 1,468 subjects were determined as H.pylori positive by recomLine (69.5%). A significant correlation between the number of positive H.pylori serum responses and DOB value was found (r s  = 0.217, P < 0.001). A mathematical approach such as FMM might be an alternative measure in optimizing the cut-off point for 13 C-UBT in community-based studies, and a second method to determine H.pylori status for subjects with borderline value of 13 C-UBT was necessary and recommended.

  11. Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women.

    PubMed

    Kinnunen, Tarja I; Tennant, Peter W G; McParlin, Catherine; Poston, Lucilla; Robson, Stephen C; Bell, Ruth

    2011-06-27

    Inexpensive, reliable objective methods are needed to measure physical activity (PA) in large scale trials. This study compared the number of pedometer step counts with accelerometer data in pregnant women in free-living conditions to assess agreement between these measures. Pregnant women (n = 58) with body mass index ≥25 kg/m(2) at median 13 weeks' gestation wore a GT1M Actigraph accelerometer and a Yamax Digi-Walker CW-701 pedometer for four consecutive days. The Spearman rank correlation coefficients were determined between pedometer step counts and various accelerometer measures of PA. Total agreement between accelerometer and pedometer step counts was evaluated by determining the 95% limits of agreement estimated using a regression-based method. Agreement between the monitors in categorising participants as active or inactive was assessed by determining Kappa. Pedometer step counts correlated moderately (r = 0.36 to 0.54) with most accelerometer measures of PA. Overall step counts recorded by the pedometer and the accelerometer were not significantly different (medians 5961 vs. 5687 steps/day, p = 0.37). However, the 95% limits of agreement ranged from -2690 to 2656 steps/day for the mean step count value (6026 steps/day) and changed substantially over the range of values. Agreement between the monitors in categorising participants to active and inactive varied from moderate to good depending on the criteria adopted. Despite statistically significant correlations and similar median step counts, the overall agreement between pedometer and accelerometer step counts was poor and varied with activity level. Pedometer and accelerometer steps cannot be used interchangeably in overweight and obese pregnant women.

  12. Display-And-Alarm Circuit For Accelerometer

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1995-01-01

    Compact accelerometer assembly consists of commercial accelerometer retrofit with display-and-alarm circuit. Provides simple means for technician attending machine to monitor vibrations. Also simpifies automatic safety shutdown by providing local alarm or shutdown signal when vibration exceeds preset level.

  13. Automatic machine-learning based identification of jogging periods from accelerometer measurements of adolescents under field conditions

    PubMed Central

    Risteska Stojkoska, Biljana; Standl, Marie; Schulz, Holger

    2017-01-01

    Background Assessment of health benefits associated with physical activity depend on the activity duration, intensity and frequency, therefore their correct identification is very valuable and important in epidemiological and clinical studies. The aims of this study are: to develop an algorithm for automatic identification of intended jogging periods; and to assess whether the identification performance is improved when using two accelerometers at the hip and ankle, compared to when using only one at either position. Methods The study used diarized jogging periods and the corresponding accelerometer data from thirty-nine, 15-year-old adolescents, collected under field conditions, as part of the GINIplus study. The data was obtained from two accelerometers placed at the hip and ankle. Automated feature engineering technique was performed to extract features from the raw accelerometer readings and to select a subset of the most significant features. Four machine learning algorithms were used for classification: Logistic regression, Support Vector Machines, Random Forest and Extremely Randomized Trees. Classification was performed using only data from the hip accelerometer, using only data from ankle accelerometer and using data from both accelerometers. Results The reported jogging periods were verified by visual inspection and used as golden standard. After the feature selection and tuning of the classification algorithms, all options provided a classification accuracy of at least 0.99, independent of the applied segmentation strategy with sliding windows of either 60s or 180s. The best matching ratio, i.e. the length of correctly identified jogging periods related to the total time including the missed ones, was up to 0.875. It could be additionally improved up to 0.967 by application of post-classification rules, which considered the duration of breaks and jogging periods. There was no obvious benefit of using two accelerometers, rather almost the same performance could be achieved from either accelerometer position. Conclusions Machine learning techniques can be used for automatic activity recognition, as they provide very accurate activity recognition, significantly more accurate than when keeping a diary. Identification of jogging periods in adolescents can be performed using only one accelerometer. Performance-wise there is no significant benefit from using accelerometers on both locations. PMID:28880923

  14. Comparison of linear and non-linear models for predicting energy expenditure from raw accelerometer data.

    PubMed

    Montoye, Alexander H K; Begum, Munni; Henning, Zachary; Pfeiffer, Karin A

    2017-02-01

    This study had three purposes, all related to evaluating energy expenditure (EE) prediction accuracy from body-worn accelerometers: (1) compare linear regression to linear mixed models, (2) compare linear models to artificial neural network models, and (3) compare accuracy of accelerometers placed on the hip, thigh, and wrists. Forty individuals performed 13 activities in a 90 min semi-structured, laboratory-based protocol. Participants wore accelerometers on the right hip, right thigh, and both wrists and a portable metabolic analyzer (EE criterion). Four EE prediction models were developed for each accelerometer: linear regression, linear mixed, and two ANN models. EE prediction accuracy was assessed using correlations, root mean square error (RMSE), and bias and was compared across models and accelerometers using repeated-measures analysis of variance. For all accelerometer placements, there were no significant differences for correlations or RMSE between linear regression and linear mixed models (correlations: r  =  0.71-0.88, RMSE: 1.11-1.61 METs; p  >  0.05). For the thigh-worn accelerometer, there were no differences in correlations or RMSE between linear and ANN models (ANN-correlations: r  =  0.89, RMSE: 1.07-1.08 METs. Linear models-correlations: r  =  0.88, RMSE: 1.10-1.11 METs; p  >  0.05). Conversely, one ANN had higher correlations and lower RMSE than both linear models for the hip (ANN-correlation: r  =  0.88, RMSE: 1.12 METs. Linear models-correlations: r  =  0.86, RMSE: 1.18-1.19 METs; p  <  0.05), and both ANNs had higher correlations and lower RMSE than both linear models for the wrist-worn accelerometers (ANN-correlations: r  =  0.82-0.84, RMSE: 1.26-1.32 METs. Linear models-correlations: r  =  0.71-0.73, RMSE: 1.55-1.61 METs; p  <  0.01). For studies using wrist-worn accelerometers, machine learning models offer a significant improvement in EE prediction accuracy over linear models. Conversely, linear models showed similar EE prediction accuracy to machine learning models for hip- and thigh-worn accelerometers and may be viable alternative modeling techniques for EE prediction for hip- or thigh-worn accelerometers.

  15. System Wide Joint Position Sensor Fault Tolerance in Robot Systems Using Cartesian Accelerometers

    NASA Technical Reports Server (NTRS)

    Aldridge, Hal A.; Juang, Jer-Nan

    1997-01-01

    Joint position sensors are necessary for most robot control systems. A single position sensor failure in a normal robot system can greatly degrade performance. This paper presents a method to obtain position information from Cartesian accelerometers without integration. Depending on the number and location of the accelerometers. the proposed system can tolerate the loss of multiple position sensors. A solution technique suitable for real-time implementation is presented. Simulations were conducted using 5 triaxial accelerometers to recover from the loss of up to 4 joint position sensors on a 7 degree of freedom robot moving in general three dimensional space. The simulations show good estimation performance using non-ideal accelerometer measurements.

  16. Interpretation of diagnostic data: 4. How to do it with a more complex table.

    PubMed

    1983-10-15

    A more complex table is especially useful when a diagnostic test produces a wide range of results and your patient's levels are near one of the extremes. The following guidelines will be useful: Identify the several cut-off points that could be used. Fill in a complex table along the lines of Table I, showing the numbers of patients at each level who have and do not have the target disorder. Generate a simple table for each cut-off point, as in Table II, and determine the sensitivity (TP rate) and specificity (TN rate) at each of them. Select the cut-off point that makes the most sense for your patient's test result and proceed as in parts 2 and 3 of our series. Alternatively, construct an ROC curve by plotting the TP and FP rates that attend each cut-off point. If you keep your tables and ROC curves close at hand, you will gradually accumulate a set of very useful guides. However, if you looked very hard at what was happening, you will probably have noticed that they are not very useful for patients whose test results fall in the middle zones, or for those with just one positive result of two tests; the post-test likelihood of disease in these patients lurches back and forth past 50%, depending on where the cut-off point is. We will show you how to tackle this problem in part 5 of our series. It involves some maths, but you will find that its very powerful clinical application can be achieved with a simple nomogram or with some simple calculations.

  17. Biological variability of transferrin saturation and unsaturated iron binding capacity

    PubMed Central

    Adams, PC; Reboussin, DM; Press, RD; Barton, JC; Acton, RT; Moses, GC; Leiendecker-Foster, C; McLaren, GD; Dawkins, FW; Gordeuk, VR; Lovato, L; Eckfeldt, JH

    2007-01-01

    Background Transferrin saturation is widely considered the preferred screening test for hemochromatosis. Unsaturated iron binding capacity has similar performance at lower cost. However, the within-person biological variability of both these tests may limit their ability at commonly used cut points to detect HFE C282Y homozygous patients. Methods The Hemochromatosis and Iron Overload Screening (HEIRS) Study screened 101,168 primary care participants for iron overload using tansferrin saturation, unsaturated iron binding capacity, ferritin and HFE C282Y and H63D genotyping. Transferrin saturation and unsaturated iron binding capacity were performed at initial screening and again when selected participants and controls returned for a clinical examination several months later. A missed case was defined as a C282Y homozygote who had transferrin saturation below cut point (45 % women, 50 % men) or unsaturated iron binding capacity above cut point (150 μmol/L women, 125 μmol/L men) at either the initial screening or clinical examination, or both, regardless of serum ferritin. Results There were 209 C282Y previously undiagnosed homozygotes with transferrin saturation and unsaturated iron binding capacity testing done at initial screening and clinical examination. Sixty-eight C282Y homozygotes (33%) would have been missed at these transferrin saturation cut points (19 men, 49 women, median SF 170 μg/L, first and third quartiles 50 and 474 μg/L), and 58 homozygotes (28 %) would have been missed at the unsaturated iron binding capacity cut points (20 men, 38 women, median SF 168 μg/L, quartiles 38 and 454 μg/L). There was no advantage to using fasting samples. Conclusions The within-person biological variability of transferrin saturation and unsaturated iron binding capacity limit their usefulness as an initial screening test for expressing C282Y homozygotes. PMID:17976429

  18. Human papilloma virus prevalence in a multiethnic screening population.

    PubMed

    Chen, Kang Mei; Stephen, Josena K; Ghanem, Tamer; Stachler, Robert; Gardner, Glendon; Jones, Lamont; Schweitzer, Vanessa P; Hall, Francis; Divine, George; Worsham, Maria J

    2013-03-01

    The goal was to determine the prevalence of high-risk HPV16 using saliva in a screening population in Detroit, Michigan. Real-time quantitative polymerase chain reaction was applied to detect HPV16 in saliva DNA from 349 screening subjects without head and neck cancer (HNC), 156 with HNC, and 19 controls. Cut points for human papilloma virus (HPV) positivity were >0 and >0.001 copy/cell. Proportions were compared between groups using exact χ(2) or Fisher exact tests (P < .05). At a cut point >0, each group had an overall HPV prevalence of more than 5%, with a higher prevalence of 30.8% in the HNC patient group. At a cut point >0.001, the prevalence was lower: 0% in the control, 1.2% in the screening, and 16.7% in the HNC group. In the latter, for both cut points, HPV prevalence was different across sites (<0.001) and significantly higher in the oropharynx than larynx or site as other after Hochberg's adjustment. At >0, women in the screening group had a higher prevalence of HPV than did men (P = .010), and at >0.001, the prevalence was higher for men in the HNC group than for women (P = .035). In the screening group, at >0, only African Americans had a higher prevalence than Caucasian Americans (P = .025). In the screening group, a 6.9% and 1.2% screening rate was noted at cut points >0 and >0.001, respectively. The results provide data to inform public health considerations of the feasibility of saliva as a screening tool in at-risk populations with the long-term goal of prophylactic vaccination against oral HPV.

  19. Sensitivity and specificity of the Geriatric Anxiety Inventory and the Hospital Anxiety and Depression Scale in the detection of anxiety disorders in older people with chronic obstructive pulmonary disease.

    PubMed

    Cheung, Gary; Patrick, Colin; Sullivan, Glenda; Cooray, Manisha; Chang, Catherina L

    2012-01-01

    Anxiety and depression are prevalent in patients with chronic obstructive pulmonary disease (COPD). This study evaluates the sensitivity and specificity of two self-administered anxiety rating scales in older people with COPD. The Geriatric Anxiety Inventory (GAI) and the Hospital Anxiety and Depression Scale (HADS) are established useful screening tools but they have not been previously validated in this population. Older people with COPD completed the GAI and the HADS along with a structured diagnostic psychiatric interview, the Mini International Neuropsychiatric Interview (MINI). The outcomes of both rating scales were compared against the diagnosis of anxiety disorders based on the MINI. Receiver operating characteristic (ROC) curves were used to identify the optimal diagnostic cut points for each scale. Fourteen (25.5%) of the 55 participants, were diagnosed with an anxiety disorder. Mean GAI and HADS-anxiety subscale scores were significantly higher in subjects with an anxiety disorder than those without the diagnosis (p = 0.002 and 0.005 respectively). Both scales demonstrated moderate diagnostic value (area under the ROC curve was 0.83 for GAI and 0.79 for HADS). Optimal cut points were ≥3 (GAI) and ≥4 (HADS-anxiety subscale). At these cut-points, the GAI had a sensitivity of 85.7%, specificity of 78.0% and the HADS had a sensitivity of 78.6%, specificity 70.7%. Our results support the use of the GAI and HADS as screening instruments for anxiety disorders in older people with COPD. The optimal cut points in this population were lower than previously recommended for both rating scales. The results of this study should be replicated before these cut points can be recommended for general use in older people with COPD.

  20. A low-noise MEMS accelerometer for unattended ground sensor applications

    NASA Astrophysics Data System (ADS)

    Speller, Kevin E.; Yu, Duli

    2004-09-01

    A low-noise micro-machined servo accelerometer has been developed for use in Unattended Ground Sensors (UGS). Compared to conventional coil-and-magnet based velocity transducers, this Micro-Electro-Mechanical System (MEMS) accelerometer offers several key benefits for battlefield monitoring. Many UGS require a compass to determine deployment orientation with respect to magnetic North. This orientation information is critical for determining the bearing of incoming signals. Conventional sensors with sensing technology based on a permanent magnet can cause interference with a compass when used in close proximity. This problem is solved with a MEMS accelerometer which does not require any magnetic materials. Frequency information below 10 Hz is valuable for identification of signal sources. Conventional seismometers used in UGS are typically limited in frequency response from 20 to 200 Hz. The MEMS accelerometer has a flat frequency response from DC to 5 kHz. The wider spectrum of signals received improves detection, classification and monitoring on the battlefield. The DC-coupled output of the MEMS accelerometer also has the added benefit of providing tilt orientation data for the deployed UGS. Other performance parameters of the MEMS accelerometer that are important to UGS such as size, weight, shock survivability, phase response, distortion, and cross-axis rejection will be discussed. Additionally, field test data from human footsteps recorded with the MEMS accelerometer will be presented.

  1. Repeat physical activity measurement by accelerometry among colorectal cancer patients--feasibility and minimal number of days of monitoring.

    PubMed

    Skender, Stephanie; Schrotz-King, Petra; Böhm, Jürgen; Abbenhardt, Clare; Gigic, Biljana; Chang-Claude, Jenny; Siegel, Erin M; Steindorf, Karen; Ulrich, Cornelia M

    2015-06-06

    Physical activity plays an important role in colorectal cancer and accelerometry is more frequently used to measure physical activity. The aim of this study was to evaluate feasibility of physical activity measurement by accelerometry in colorectal cancer patients under free-living conditions at 6, 12 and 24 months after surgery, to evaluate the appropriate wear time and to compare results to pedometry. Colorectal cancer patients (stage 0/I-IV) from the ColoCare study were asked to optionally wear an accelerometer and a pedometer for ten consecutive days 6, 12 and 24 months post-surgery. Participants completed a feedback questionnaire about the accelerometer measurement. The course of moderate-to-vigorous physical activity over the 10 days was investigated. Additionally, daily step counts from accelerometers and pedometers were compared. In total, there were 317 individual time points, at which 198 participants were asked to wear an accelerometer. Fifty-nine% initially agreed to participate and of these, 83% (n = 156) completed the assessment with at least 4 days of data. Twenty-one% more consents were obtained when participants were asked on a face-to-face basis compared to recruitment by telephone (P = 0.0002). There were no significant differences in time spent in moderate-to-vigorous physical activity between different wear-time lengths of accelerometry. Both Spearman and intraclass correlation coefficients showed strong correlations (0.92-0.99 and 0.84-0.99, respectively) of moderate-to-vigorous physical activity across 3, 4, 7 and 10 days measurement. Step counts measured by accelerometry and pedometry were strongly correlated (ρ = 0.91, P < 0.0001). This study suggest that accelerometry is a feasible method to assess physical activity in free-living colorectal cancer patients and that three valid days of physical activity measurement are sufficient for an accurate assessment.

  2. Aligned Carbon Nanotube Tape for Sensor Applications

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical properties CNT tape as a strain gauge in Structural Health Monitoring will provide an excellent material to embed within composite structures

  3. Visualizing Flutter Mechanism as Traveling Wave Through Animation of Simulation Results for the Semi-Span Super-Sonic Transport Wind-Tunnel Model

    NASA Technical Reports Server (NTRS)

    Christhilf, David M.

    2014-01-01

    It has long been recognized that frequency and phasing of structural modes in the presence of airflow play a fundamental role in the occurrence of flutter. Animation of simulation results for the long, slender Semi-Span Super-Sonic Transport (S4T) wind-tunnel model demonstrates that, for the case of mass-ballasted nacelles, the flutter mode can be described as a traveling wave propagating downstream. Such a characterization provides certain insights, such as (1) describing the means by which energy is transferred from the airflow to the structure, (2) identifying airspeed as an upper limit for speed of wave propagation, (3) providing an interpretation for a companion mode that coalesces in frequency with the flutter mode but becomes very well damped, (4) providing an explanation for bursts of response to uniform turbulence, and (5) providing an explanation for loss of low frequency (lead) phase margin with increases in dynamic pressure (at constant Mach number) for feedback systems that use sensors located upstream from active control surfaces. Results from simulation animation, simplified modeling, and wind-tunnel testing are presented for comparison. The simulation animation was generated using double time-integration in Simulink of vertical accelerometer signals distributed over wing and fuselage, along with time histories for actuated control surfaces. Crossing points for a zero-elevation reference plane were tracked along a network of lines connecting the accelerometer locations. Accelerometer signals were used in preference to modal displacement state variables in anticipation that the technique could be used to animate motion of the actual wind-tunnel model using data acquired during testing. Double integration of wind-tunnel accelerometer signals introduced severe drift even with removal of both position and rate biases such that the technique does not currently work. Using wind-tunnel data to drive a Kalman filter based upon fitting coefficients to analytical mode shapes might provide a better means to animate the wind tunnel data.

  4. Physical activity and sarcopenic obesity: definition, assessment, prevalence and mechanism.

    PubMed

    Lee, Duck-Chul; Shook, Robin P; Drenowatz, Clemens; Blair, Steven N

    2016-09-01

    Sarcopenic obesity is the coexistance of sarcopenia and obesity. Modern sarcopenia definition includes low muscle mass, weak muscle strength (handgrip strength) and poor physical function (slow walking), although the clinical definition of each varies worldwide. The cut-points for low muscle mass for men and women using appendicular lean mass divided by height (kg/m 2 ) are ≤7.0 and ≤5.4 in Asians, and ≤7.23 and ≤5.67 in Caucasians, respectively. The cut-points for weak handgrip strength (kg) for men and women are <26 and <18 in Asians, and <30 and <20 in Caucasians, respectively. The cut-point for slow walking is ≤0.8 m/s in men and women. Current data suggest the potential benefits of physical activity and fitness on sarcopenic obesity in older adults.

  5. Research on subsurface defects of potassium dihydrogen phosphate crystals fabricated by single point diamond turning technique

    NASA Astrophysics Data System (ADS)

    Tie, Guipeng; Dai, Yifan; Guan, Chaoliang; Chen, Shaoshan; Song, Bing

    2013-03-01

    Potassium dihydrogen phosphate (KDP) crystals, which are widely used in high-power laser systems, are required to be free of defects on fabricated subsurfaces. The depth of subsurface defects (SSD) of KDP crystals is significantly influenced by the parameters used in the single point diamond turning technique. In this paper, based on the deliquescent magnetorheological finishing technique, the SSD of KDP crystals is observed and the depths under various cutting parameters are detected and discussed. The results indicate that no SSD is generated under small parameters and with the increase of cutting parameters, SSD appears and the depth rises almost linearly. Although the ascending trends of SSD depths caused by cutting depth and feed rate are much alike, the two parameters make different contributions. Taking the same material removal efficiency as a criterion, a large cutting depth generates shallower SSD depth than a large feed rate. Based on the experiment results, an optimized cutting procedure is obtained to generate defect-free surfaces.

  6. WWBT? What Would Ben Think about Killer Apps, Cutting Edges, and Tipping Points in the History of Weather and Climate?

    NASA Astrophysics Data System (ADS)

    Fleming, J. R.

    2006-12-01

    This paper examines the history of weather and climate since 1706 along three intertwined analytical axes: technology (killer apps), science (cutting edges), and social issues (tipping points). For example, Franklin's best-known killer app, the lightning rod, gains added significance when seen in light of his cutting edge contributions to the science of electricity, his lifelong promotion of useful knowledge, and the societal tipping point his work triggered in our relationship to the sky. Subsequently, other major tipping points and conceptual shifts followed the introduction of telegraphy, radio, television, digital computers, and rocketry into meteorology. Following an analysis of the career and contributions of Benjamin Franklin (1706-1790), the paper examines later historical moments and watersheds, not merely in retrospect, but from the perspective of leading participants at the time. It focuses on technologies of significant promise, especially those involving electro- magnetism, up to and including the dawn of the twenty-first century, and asks playfully, "What would Ben think?"

  7. Implementation of accelerometer sensor module and fall detection monitoring system based on wireless sensor network.

    PubMed

    Lee, Youngbum; Kim, Jinkwon; Son, Muntak; Lee, Myoungho

    2007-01-01

    This research implements wireless accelerometer sensor module and algorithm to determine wearer's posture, activity and fall. Wireless accelerometer sensor module uses ADXL202, 2-axis accelerometer sensor (Analog Device). And using wireless RF module, this module measures accelerometer signal and shows the signal at ;Acceloger' viewer program in PC. ADL algorithm determines posture, activity and fall that activity is determined by AC component of accelerometer signal and posture is determined by DC component of accelerometer signal. Those activity and posture include standing, sitting, lying, walking, running, etc. By the experiment for 30 subjects, the performance of implemented algorithm was assessed, and detection rate for postures, motions and subjects was calculated. Lastly, using wireless sensor network in experimental space, subject's postures, motions and fall monitoring system was implemented. By the simulation experiment for 30 subjects, 4 kinds of activity, 3 times, fall detection rate was calculated. In conclusion, this system can be application to patients and elders for activity monitoring and fall detection and also sports athletes' exercise measurement and pattern analysis. And it can be expected to common person's exercise training and just plaything for entertainment.

  8. Drift Mode Accelerometry for Spaceborne Gravity Measurements

    NASA Astrophysics Data System (ADS)

    Conklin, J. W.; Shelley, R.; Chilton, A.; Olatunde, T.; Ciani, G.; Mueller, G.

    2014-12-01

    A drift mode accelerometer is a precision instrument for spacecraft that overcomes much of the acceleration noise and readout dynamic range limitations of traditional electrostatic accelerometers. It has the potential of achieving acceleration noise performance similar to that of drag-free systems over a restricted frequency band without the need for external drag-free control or continuous spacecraft propulsion. Like traditional accelerometers, the drift mode accelerometer contains a high-density test mass surrounded by an electrode housing, which can control and sense all six degrees of freedom of the test mass. Unlike traditional accelerometers, the suspension system is operated with a low duty cycle so that the limiting suspension force noise only acts over brief, known time intervals, which can be accounted for in the data analysis. The readout is performed using a laser interferometer which is immune to the dynamic range limitations of even the best voltage references typically used to determine the inertial acceleration of electrostatic accelerometers. This presentation describes operation and performance modeling for such a device with respect to a low Earth orbiting satellite geodesy mission. Methods for testing the drift mode accelerometer with the University of Florida precision torsion pendulum will also be discussed.

  9. Can mobile phones used in strong motion seismology?

    NASA Astrophysics Data System (ADS)

    D'Alessandro, Antonino; D'Anna, Giuseppe

    2013-04-01

    Micro Electro-Mechanical Systems (MEMS) accelerometers are electromechanical devices able to measure static or dynamic accelerations. In the 1990s MEMS accelerometers revolutionized the automotive-airbag system industry and are currently widely used in laptops, game controllers and mobile phones. Nowadays MEMS accelerometers seems provide adequate sensitivity, noise level and dynamic range to be applicable to earthquake strong motion acquisition. The current use of 3 axes MEMS accelerometers in mobile phone maybe provide a new means to easy increase the number of observations when a strong earthquake occurs. However, before utilize the signals recorded by a mobile phone equipped with a 3 axes MEMS accelerometer for any scientific porpoise, it is fundamental to verify that the signal collected provide reliable records of ground motion. For this reason we have investigated the suitability of the iPhone 5 mobile phone (one of the most popular mobile phone in the world) for strong motion acquisition. It is provided by several MEMS devise like a three-axis gyroscope, a three-axis electronic compass and a the LIS331DLH three-axis accelerometer. The LIS331DLH sensor is a low-cost high performance three axes linear accelerometer, with 16 bit digital output, produced by STMicroelectronics Inc. We have tested the LIS331DLH MEMS accelerometer using a vibrating table and the EpiSensor FBA ES-T as reference sensor. In our experiments the reference sensor was rigidly co-mounted with the LIS331DHL MEMS sensor on the vibrating table. We assessment the MEMS accelerometer in the frequency range 0.2-20 Hz, typical range of interesting in strong motion seismology and earthquake engineering. We generate both constant and damped sine waves with central frequency starting from 0.2 Hz until 20 Hz with step of 0.2 Hz. For each frequency analyzed we generate sine waves with mean amplitude 50, 100, 200, 400, 800 and 1600 mg0. For damped sine waves we generate waveforms with initial amplitude of 2 g0. Our tests show as, in the frequency and amplitude range analyzed (0.2-20 Hz, 10-2000 mg0), the LIS331DLH MEMS accelerometer have excellent frequency and phase response, comparable with that of some standard FBA accelerometer used in strong motion seismology. However, we found that the signal recorded by the LIS331DLH MEMS accelerometer slightly underestimates the real acceleration (of about 2.5%). This suggests that may be important to calibrate a MEMS sensor before using it in scientific applications. A drawback of the LIS331DLH MEMS accelerometer is its low sensitivity. This is an important limitation of all the low cost MEMS accelerometers; therefore nowadays they are desirable to use only in strong motion seismology. However, the rapid development of this technology will lead in the coming years to the development of high sensitivity and low noise digital MEMS sensors that may be replace the current seismic accelerometer used in seismology. Actually, the real main advantage of these sensors is their common use in the mobile phones.

  10. Feasibility of Tactical Air Delivery Resupply Using Gliders

    DTIC Science & Technology

    2016-12-01

    using modern design and manufacturing techniques including AutoCAD, 3D printing , laser cutting and CorelDraw, and conducting field testing and...Sparrow,” using modern design and manufacturing techniques including AutoCAD, 3D printing , laser cutting and CorelDraw, and conducting field testing and...the desired point(s) of impact due to the atmospheric three-dimensional ( 3D ) wind and density field encountered by the descending load under canopy

  11. Rectilinear accelerometer possesses self- calibration feature

    NASA Technical Reports Server (NTRS)

    Henderson, R. B.

    1966-01-01

    Rectilinear accelerometer operates from an ac source with a phase-sensitive ac voltage output proportional to the applied accelerations. The unit includes an independent circuit for self-test which provides a sensor output simulating an acceleration applied to the sensitive axis of the accelerometer.

  12. Operationalizing hippocampal volume as an enrichment biomarker for amnestic mild cognitive impairment trials: effect of algorithm, test-retest variability, and cut point on trial cost, duration, and sample size.

    PubMed

    Yu, Peng; Sun, Jia; Wolz, Robin; Stephenson, Diane; Brewer, James; Fox, Nick C; Cole, Patricia E; Jack, Clifford R; Hill, Derek L G; Schwarz, Adam J

    2014-04-01

    The objective of this study was to evaluate the effect of computational algorithm, measurement variability, and cut point on hippocampal volume (HCV)-based patient selection for clinical trials in mild cognitive impairment (MCI). We used normal control and amnestic MCI subjects from the Alzheimer's Disease Neuroimaging Initiative 1 (ADNI-1) as normative reference and screening cohorts. We evaluated the enrichment performance of 4 widely used hippocampal segmentation algorithms (FreeSurfer, Hippocampus Multi-Atlas Propagation and Segmentation (HMAPS), Learning Embeddings Atlas Propagation (LEAP), and NeuroQuant) in terms of 2-year changes in Mini-Mental State Examination (MMSE), Alzheimer's Disease Assessment Scale-Cognitive Subscale (ADAS-Cog), and Clinical Dementia Rating Sum of Boxes (CDR-SB). We modeled the implications for sample size, screen fail rates, and trial cost and duration. HCV based patient selection yielded reduced sample sizes (by ∼40%-60%) and lower trial costs (by ∼30%-40%) across a wide range of cut points. These results provide a guide to the choice of HCV cut point for amnestic MCI clinical trials, allowing an informed tradeoff between statistical and practical considerations. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women

    PubMed Central

    2011-01-01

    Background Inexpensive, reliable objective methods are needed to measure physical activity (PA) in large scale trials. This study compared the number of pedometer step counts with accelerometer data in pregnant women in free-living conditions to assess agreement between these measures. Methods Pregnant women (n = 58) with body mass index ≥25 kg/m2 at median 13 weeks' gestation wore a GT1M Actigraph accelerometer and a Yamax Digi-Walker CW-701 pedometer for four consecutive days. The Spearman rank correlation coefficients were determined between pedometer step counts and various accelerometer measures of PA. Total agreement between accelerometer and pedometer step counts was evaluated by determining the 95% limits of agreement estimated using a regression-based method. Agreement between the monitors in categorising participants as active or inactive was assessed by determining Kappa. Results Pedometer step counts correlated moderately (r = 0.36 to 0.54) with most accelerometer measures of PA. Overall step counts recorded by the pedometer and the accelerometer were not significantly different (medians 5961 vs. 5687 steps/day, p = 0.37). However, the 95% limits of agreement ranged from -2690 to 2656 steps/day for the mean step count value (6026 steps/day) and changed substantially over the range of values. Agreement between the monitors in categorising participants to active and inactive varied from moderate to good depending on the criteria adopted. Conclusions Despite statistically significant correlations and similar median step counts, the overall agreement between pedometer and accelerometer step counts was poor and varied with activity level. Pedometer and accelerometer steps cannot be used interchangeably in overweight and obese pregnant women. PMID:21703033

  14. Accelerometer thresholds: Accounting for body mass reduces discrepancies between measures of physical activity for individuals with overweight and obesity.

    PubMed

    Raiber, Lilian; Christensen, Rebecca A G; Jamnik, Veronica K; Kuk, Jennifer L

    2017-01-01

    The objective of this study was to explore whether accelerometer thresholds that are adjusted to account for differences in body mass influence discrepancies between self-report and accelerometer-measured physical activity (PA) volume for individuals with overweight and obesity. We analyzed 6164 adults from the National Health and Nutrition Examination Survey between 2003-2006. Established accelerometer thresholds were adjusted to account for differences in body mass to produce a similar energy expenditure (EE) rate as individuals with normal weight. Moderate-, vigorous-, and moderate- to vigorous-intensity PA (MVPA) durations were measured using established and adjusted accelerometer thresholds and compared with self-report. Durations of self-report were longer than accelerometer-measured MVPA using established thresholds (normal weight: 57.8 ± 2.4 vs 9.0 ± 0.5 min/day, overweight: 56.1 ± 2.7 vs 7.4 ± 0.5 min/day, and obesity: 46.5 ± 2.2 vs 3.7 ± 0.3 min/day). Durations of subjective and objective PA were negatively associated with body mass index (BMI) (P < 0.05). Using adjusted thresholds increased MVPA durations, and reduced discrepancies between accelerometer and self-report measures for overweight and obese groups by 6.0 ± 0.3 min/day and 17.7 ± 0.8 min/day, respectively (P < 0.05). Using accelerometer thresholds that represent equal EE rates across BMI categories reduced the discrepancies between durations of subjective and objective PA for overweight and obese groups. However, accelerometer-measured PA generally remained shorter than durations of self-report within all BMI categories. Further research may be necessary to improve analytical approaches when using objective measures of PA for individuals with overweight or obesity.

  15. Is questionnaire-based sitting time inaccurate and can it be improved? A cross-sectional investigation using accelerometer-based sitting time

    PubMed Central

    Gupta, Nidhi; Christiansen, Caroline Stordal; Hanisch, Christiana; Bay, Hans; Burr, Hermann; Holtermann, Andreas

    2017-01-01

    Objectives To investigate the differences between a questionnaire-based and accelerometer-based sitting time, and develop a model for improving the accuracy of questionnaire-based sitting time for predicting accelerometer-based sitting time. Methods 183 workers in a cross-sectional study reported sitting time per day using a single question during the measurement period, and wore 2 Actigraph GT3X+ accelerometers on the thigh and trunk for 1–4 working days to determine their actual sitting time per day using the validated Acti4 software. Least squares regression models were fitted with questionnaire-based siting time and other self-reported predictors to predict accelerometer-based sitting time. Results Questionnaire-based and accelerometer-based average sitting times were ≈272 and ≈476 min/day, respectively. A low Pearson correlation (r=0.32), high mean bias (204.1 min) and wide limits of agreement (549.8 to −139.7 min) between questionnaire-based and accelerometer-based sitting time were found. The prediction model based on questionnaire-based sitting explained 10% of the variance in accelerometer-based sitting time. Inclusion of 9 self-reported predictors in the model increased the explained variance to 41%, with 10% optimism using a resampling bootstrap validation. Based on a split validation analysis, the developed prediction model on ≈75% of the workers (n=132) reduced the mean and the SD of the difference between questionnaire-based and accelerometer-based sitting time by 64% and 42%, respectively, in the remaining 25% of the workers. Conclusions This study indicates that questionnaire-based sitting time has low validity and that a prediction model can be one solution to materially improve the precision of questionnaire-based sitting time. PMID:28093433

  16. Measurement of peak impact loads differ between accelerometers - Effects of system operating range and sampling rate.

    PubMed

    Ziebart, Christina; Giangregorio, Lora M; Gibbs, Jenna C; Levine, Iris C; Tung, James; Laing, Andrew C

    2017-06-14

    A wide variety of accelerometer systems, with differing sensor characteristics, are used to detect impact loading during physical activities. The study examined the effects of system characteristics on measured peak impact loading during a variety of activities by comparing outputs from three separate accelerometer systems, and by assessing the influence of simulated reductions in operating range and sampling rate. Twelve healthy young adults performed seven tasks (vertical jump, box drop, heel drop, and bilateral single leg and lateral jumps) while simultaneously wearing three tri-axial accelerometers including a criterion standard laboratory-grade unit (Endevco 7267A) and two systems primarily used for activity-monitoring (ActiGraph GT3X+, GCDC X6-2mini). Peak acceleration (gmax) was compared across accelerometers, and errors resulting from down-sampling (from 640 to 100Hz) and range-limiting (to ±6g) the criterion standard output were characterized. The Actigraph activity-monitoring accelerometer underestimated gmax by an average of 30.2%; underestimation by the X6-2mini was not significant. Underestimation error was greater for tasks with greater impact magnitudes. gmax was underestimated when the criterion standard signal was down-sampled (by an average of 11%), range limited (by 11%), and by combined down-sampling and range-limiting (by 18%). These effects explained 89% of the variance in gmax error for the Actigraph system. This study illustrates that both the type and intensity of activity should be considered when selecting an accelerometer for characterizing impact events. In addition, caution may be warranted when comparing impact magnitudes from studies that use different accelerometers, and when comparing accelerometer outputs to osteogenic impact thresholds proposed in literature. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  17. Second United States Microgravity Payload: One Year Report

    NASA Technical Reports Server (NTRS)

    Curreri, Peter A. (Editor); McCauley, Dannah E. (Editor)

    1996-01-01

    The second United States Microgravity Payload (USMP-2), flown in March 1994, carried four major microgravity experiments plus a sophisticated accelerometer system. The USMP program is designed to accommodate experiments requiring extensive resources short of a full Spacelab mission. The four USMP-2 experiments dealt with understanding fundamental aspects of materials behavior, three with the formation of crystals from melts and one with the critical point of a noble gas. This successful, scientifically rich mission also demonstrated telescience operations.

  18. Contributions to the problem of piezoelectric accelerometer calibration. [using lock-in voltmeter

    NASA Technical Reports Server (NTRS)

    Jakab, I.; Bordas, A.

    1974-01-01

    After discussing the principal calibration methods for piezoelectric accelerometers, an experimental setup for accelerometer calibration by the reciprocity method is described It is shown how the use of a lock-in voltmeter eliminates errors due to viscous damping and electrical loading.

  19. Review of physical activity measurement using accelerometers in older adults: considerations for research design and conduct.

    PubMed

    Murphy, Susan L

    2009-02-01

    Accelerometers are being increasingly used in studies of physical activity (PA) among older adults, however the use of these monitors requires some specialized knowledge and up-to-date information on technological innovations. The purpose of this review article is to provide researchers with a guide to some commonly-used accelerometers in order to better design and conduct PA research with older adults. A literature search was conducted to obtain all available literature on commonly-used accelerometers in older adult samples with specific attention to articles discussing research design. The use of accelerometers in older adults requires a basic understanding of the type being used, rationale for their placement, and attention to calibration when needed. The updated technology in some monitors should make study conduct less difficult, however comparison studies of the newer versus the older generation models will be needed. Careful considerations for design and conduct of accelerometer research as outlined in this review should help to enhance the quality and comparability of future research studies.

  20. Capturing Ultraviolet Radiation Exposure and Physical Activity: Feasibility Study and Comparison Between Self-Reports, Mobile Apps, Dosimeters, and Accelerometers.

    PubMed

    Hacker, Elke; Horsham, Caitlin; Allen, Martin; Nathan, Andrea; Lowe, John; Janda, Monika

    2018-04-17

    Skin cancer is the most prevalent cancer in Australia. Skin cancer prevention programs aim to reduce sun exposure and increase sun protection behaviors. Effectiveness is usually assessed through self-report. It was the aim of this study to test the acceptance and validity of a newly developed ultraviolet radiation (UVR) exposure app, designed to reduce the data collection burden to research participants. Physical activity data was collected because a strong focus on sun avoidance may result in unhealthy reductions in physical activity. This paper provides lessons learned from collecting data from participants using paper diaries, a mobile app, dosimeters, and accelerometers for measuring end-points of UVR exposure and physical activity. Two participant groups were recruited through social and traditional media campaigns 1) Group A-UVR Diaries and 2) Group B-Physical Activity. In Group A, nineteen participants wore an UVR dosimeter wristwatch (University of Canterbury, New Zealand) when outside for 7 days. They also recorded their sun exposure and physical activity levels using both 1) the UVR diary app and 2) a paper UVR diary. In Group B, 55 participants wore an accelerometer (Actigraph, Pensacola, FL, USA) for 14 days and completed the UVR diary app. Data from the UVR diary app were compared with UVR dosimeter wristwatch, accelerometer, and paper UVR diary data. Cohen kappa coefficient score was used to determine if there was agreement between categorical variables for different UVR data collection methods and Spearman rank correlation coefficient was used to determine agreement between continuous accelerometer data and app-collected self-report physical activity. The mean age of participants in Groups A (n=19) and B (n=55) was 29.3 and 25.4 years, and 63% (12/19) and 75% (41/55) were females, respectively. Self-reported sun exposure data in the UVR app correlated highly with UVR dosimetry (κ=0.83, 95% CI 0.64-1.00, P<.001). Correlation between self-reported UVR app and accelerometer-collected moderate to vigorous physical activity data was low (ρ=0.23, P=.10), while agreement for low-intensity physical activity was significantly different (ρ=-0.49, P<.001). Seventy-nine percent of participants preferred the app over the paper diary for daily self-report of UVR exposure and physical activity. This feasibility study highlights self-report using an UVR app can reliably collect personal UVR exposure, but further improvements are required before the app can also be used to collect physical activity data. ©Elke Hacker, Caitlin Horsham, Martin Allen, Andrea Nathan, John Lowe, Monika Janda. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 17.04.2018.

  1. C-arm rotation encoding with accelerometers.

    PubMed

    Grzeda, Victor; Fichtinger, Gabor

    2010-07-01

    Fluoroscopic C-arms are being incorporated in computer-assisted interventions in increasing number. For these applications to work, the relative poses of imaging must be known. To find the pose, tracking methods such as optical cameras, electromagnetic trackers, and radiographic fiducials have been used-all hampered by significant shortcomings. We propose to recover the rotational pose of the C-arm using the angle-sensing ability of accelerometers, by exploiting the capability of the accelerometer to measure tilt angles. By affixing the accelerometer to a C-arm, the accelerometer tracks the C-arm pose during rotations of the C-arm. To demonstrate this concept, a C-arm analogue was constructed with a webcam device affixed to the C-arm model to mimic X-ray imaging. Then, measuring the offset between the accelerometer angle readings to the webcam pose angle, an angle correction equation (ACE) was created to properly tracking the C-arm rotational pose. Several tests were performed on the webcam C-arm model using the ACEs to tracking the primary and secondary angle rotations of the model. We evaluated the capability of linear and polynomial ACEs to tracking the webcam C-arm pose angle for different rotational scenarios. The test results showed that the accelerometer could track the pose of the webcam C-arm model with an accuracy of less than 1.0 degree. The accelerometer was successful in sensing the C-arm's rotation with clinically adequate accuracy in the C-arm webcam model.

  2. Drift mode accelerometry for spaceborne gravity measurements

    NASA Astrophysics Data System (ADS)

    Conklin, John W.

    2015-11-01

    A drift mode accelerometer is a precision instrument for spacecraft that overcomes much of the acceleration noise and readout dynamic range limitations of traditional electrostatic accelerometers. It has the potential of achieving acceleration noise performance similar to that of drag-free systems over a restricted frequency band without the need for external drag-free control or continuous spacecraft propulsion. Like traditional accelerometers, the drift mode accelerometer contains a high-density test mass surrounded by an electrode housing, which can control and sense all six degrees of freedom of the test mass. Unlike traditional accelerometers, the suspension system is operated with a low duty cycle so that the limiting suspension force noise only acts over brief, known time intervals, which can be neglected in the data analysis. The readout is performed using a laser interferometer which is immune to the dynamic range limitations of even the best voltage references typically used to determine the inertial acceleration of electrostatic accelerometers. The drift mode accelerometer is a novel offshoot of the like-named operational mode of the LISA Pathfinder spacecraft, in which its test mass suspension system is cycled on and off to estimate the acceleration noise associated with the front-end electronics. This paper presents the concept of a drift mode accelerometer, describes the operation of such a device, develops models for its performance with respect to non-drag-free satellite geodesy and gravitational wave missions, and discusses plans for testing the performance of a prototype sensor in the laboratory using torsion pendula.

  3. A triaxial accelerometer monkey algorithm for optimal sensor placement in structural health monitoring

    NASA Astrophysics Data System (ADS)

    Jia, Jingqing; Feng, Shuo; Liu, Wei

    2015-06-01

    Optimal sensor placement (OSP) technique is a vital part of the field of structural health monitoring (SHM). Triaxial accelerometers have been widely used in the SHM of large-scale structures in recent years. Triaxial accelerometers must be placed in such a way that all of the important dynamic information is obtained. At the same time, the sensor configuration must be optimal, so that the test resources are conserved. The recommended practice is to select proper degrees of freedom (DOF) based upon several criteria and the triaxial accelerometers are placed at the nodes corresponding to these DOFs. This results in non-optimal placement of many accelerometers. A ‘triaxial accelerometer monkey algorithm’ (TAMA) is presented in this paper to solve OSP problems of triaxial accelerometers. The EFI3 measurement theory is modified and involved in the objective function to make it more adaptable in the OSP technique of triaxial accelerometers. A method of calculating the threshold value based on probability theory is proposed to improve the healthy rate of monkeys in a troop generation process. Meanwhile, the processes of harmony ladder climb and scanning watch jump are proposed and given in detail. Finally, Xinghai NO.1 Bridge in Dalian is implemented to demonstrate the effectiveness of TAMA. The final results obtained by TAMA are compared with those of the original monkey algorithm and EFI3 measurement, which show that TAMA can improve computational efficiency and get a better sensor configuration.

  4. Consumer evaluation of palatability characteristics of a beef value-added cut compared to common retail cuts.

    PubMed

    Lepper-Blilie, A N; Berg, E P; Germolus, A J; Buchanan, D S; Berg, P T

    2014-01-01

    The objectives of this study were to educate consumers about value-added beef cuts and evaluate their palatability responses of a value cut and three traditional cuts. Three hundred and twenty-two individuals participated in the beef value cut education seminar series presented by trained beef industry educators. Seminar participants evaluated tenderness, juiciness, flavor, and overall like of four samples, bottom round, top sirloin, ribeye, and a value cut (Delmonico or Denver), on a 9-point scale. The ribeye and the value cut were found to be similar in all four attributes and differed from the top sirloin and bottom round. Correlations and regression analysis found that flavor was the largest influencing factor for overall like for the ribeye, value cut, and top sirloin. The value cut is comparable to the ribeye and can be a less expensive replacement. © 2013.

  5. Investigating the CO 2 laser cutting parameters of MDF wood composite material

    NASA Astrophysics Data System (ADS)

    Eltawahni, H. A.; Olabi, A. G.; Benyounis, K. Y.

    2011-04-01

    Laser cutting of medium density fibreboard (MDF) is a complicated process and the selection of the process parameters combinations is essential to get the highest quality cut section. This paper presents a means for selecting the process parameters for laser cutting of MDF based on the design of experiments (DOE) approach. A CO 2 laser was used to cut three thicknesses, 4, 6 and 9 mm, of MDF panels. The process factors investigated are: laser power, cutting speed, air pressure and focal point position. In this work, cutting quality was evaluated by measuring the upper kerf width, the lower kerf width, the ratio between the upper kerf width to the lower kerf width, the cut section roughness and the operating cost. The effect of each factor on the quality measures was determined. The optimal cutting combinations were presented in favours of high quality process output and in favours of low cutting cost.

  6. Cutting head for ultrasonic lithotripsy

    NASA Technical Reports Server (NTRS)

    Anguluo, E. D.; Goodfriend, R. (Inventor)

    1985-01-01

    A cutting head for attachment to the end of the wire probe of an ultrasonic kidney stone disintegration instrument is described. The cutting head has a plurality of circumferentially arranged teeth formed at one end thereof to provide a cup shaped receptacle for kidney stones encountered during the disintegration procedure. An integral reduced diameter collar diminishes stress points in the wire and reduce breakage thereof.

  7. Cutting Head for Ultrasonic Lithotripsy

    NASA Technical Reports Server (NTRS)

    Angulo, Earl D. (Inventor); Goodfriend, Roger (Inventor)

    1989-01-01

    A cutting head for attachment to the end of the wire probe of an ultrasonic kidney stone disintegration instrument. The cutting head has a plurality of circumferentially arranged teeth formed at one end thereof to provide a cup-shaped receptacle for kidney stones encountered during the disintegration procedure. An integral reduced diameter collar diminishes stress points in the wire and reduces breakage thereof.

  8. Laser cutting system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dougherty, Thomas J

    A workpiece cutting apparatus includes a laser source, a first suction system, and a first finger configured to guide a workpiece as it moves past the laser source. The first finger includes a first end provided adjacent a point where a laser from the laser source cuts the workpiece, and the first end of the first finger includes an aperture in fluid communication with the first suction system.

  9. A description of disordered eating behaviors in Latino males

    PubMed Central

    Reyes-Rodríguez, Mae Lynn; Sala, Margarita; Von Holle, Ann; Unikel, Claudia; Bulik, Cynthia M.; Cámara-Fuentes, Luis; Suárez-Torres, Alba

    2011-01-01

    Objective To explore disordered eating and eating disorders (ED) in Latino males. Participants 722 male college students from a larger prevalence study conducted in the University of Puerto Rico (UPR) system. Method Participants were selected from a list of sections of required courses for first-year students on each campus. Self report instruments were used to explore ED symptoms (EAT-26 & BULIT-26) and depression (BDI). Results Overall, 2.26% scored above the cut-off point on the BULIT-R and 5.08% score above the cut-off point on the EAT-26. Of the males, 4.43% reported sufficient frequency and severity to approximate DSM-IV criteria for BN. Depression symptomatology was found in those who scored above the cut-off point on both instruments of ED. Conclusion College health practitioners should be aware of disordered eating in Latino males and include them in efforts to detect disordered eating behaviors in college students. PMID:21308586

  10. A cautionary note about the cross-national and clinical validity of cut-off points for the Maslach Burnout Inventory.

    PubMed

    Schaufeli, W B; Van Dierendonck, D

    1995-06-01

    In the present study, burnout scores of three samples, as measured with the Maslach Burnout Inventory, were compared: (1) the normative American sample from the test-manual (N = 10,067), (2) the normative Dutch sample (N = 3,892), and (3) a Dutch outpatient sample (N = 142). Generally, the highest burnout scores were found for the outpatient sample, followed by the American and Dutch normative samples, respectively. Slightly different patterns were noted for each of the three components. Probably sampling bias, i.e., the healthy worker effect, or cultural value patterns, i.e., femininity versus masculinity, might be responsible for the results. It is concluded that extreme caution is required when cut-off points are used to classify individuals by burnout scores; only nation-specific and clinically derived cut-off points should be employed.

  11. [Validation of the Eating Attitudes Test as a screening instrument for eating disorders in general population].

    PubMed

    Peláez-Fernández, María Angeles; Ruiz-Lázaro, Pedro Manuel; Labrador, Francisco Javier; Raich, Rosa María

    2014-02-20

    To validate the best cut-off point of the Eating Attitudes Test (EAT-40), Spanish version, for the screening of eating disorders (ED) in the general population. This was a transversal cross-sectional study. The EAT-40 Spanish version was administered to a representative sample of 1.543 students, age range 12 to 21 years, in the Region of Madrid. Six hundred and two participants (probable cases and a random sample of controls) were interviewed. The best diagnostic prediction was obtained with a cut-off point of 21, with sensitivity: 88.2%; specificity: 62.1%; positive predictive value: 17.7%; negative predictive value: 62.1%. Use of a cut-off point of 21 is recommended in epidemiological studies of eating disorders in the Spanish general population. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  12. Dust mite, cockroach, cat, and dog allergen concentrations in homes of asthmatic children in the northeastern United States: impact of socioeconomic factors and population density.

    PubMed Central

    Leaderer, Brian P; Belanger, Kathleen; Triche, Elizabeth; Holford, Theodore; Gold, Diane R; Kim, Young; Jankun, Thomas; Ren, Ping; McSharry Je, Jean-ellen; Platts-Mills, Thomas A E; Chapman, Martin D; Bracken, Michael B

    2002-01-01

    Home exposures to aeroallergens are an important environmental factor in allergic sensitization and in the development and exacerbation of asthma. We assessed variations in home concentrations of dust mite, cockroach, cat, and dog allergens in dust collected in the main living areas of asthmatics' homes by family income, mother's education, dwelling type, population density, household population density, and ethnicity in Connecticut and south-central Massachusetts. Dust samples were collected at the time of home interview in 999 homes as part of an ongoing longitudinal birth cohort study of 1,002 infants and their asthmatic siblings. The analysis employed lower and upper cut points for group 1 dust mite (> or = 2.0 microg/g and > or = 10 microg/g), cockroach (> or = 1.0 U/g and > or = 4.0 U/g), cat (> or = 1.0 microg/g and > or = 8.0 ug/g), and dog (> or = 2.0 microg/g and > or = 10.0 microg/g) allergens. Subject residences were geocoded to assess population density from the U.S. Census, and multiple logistic regression was used to control for confounding. The portion of homes at the lower cut point for dust mite, cockroach, cat, and dog allergens were 46.9%, 24.9%, 42.2%, and 35.6%, respectively; the upper cut point for each of the allergens was reached in 22.4%, 13.4%, 21.0%, and 22.9% of the homes, respectively. In all, 86.0% of the homes had at least one allergen at the lower cut point, and 58.0% had at least one allergen at the upper cut point. Forty-nine percent of the homes had two or more allergens at the lower cut point, and 19.7% had two or more allergens at the upper cut point. Higher education of the mother, higher household income, living in a single-family home in a less densely populated area with fewer people per room, and being a white household were associated with elevated dust mite, cat, and dog allergens and low cockroach allergen. In contrast, low income, living in a multifamily home in a high population density area with a higher occupancy rate per room, and being a Hispanic or black household were associated with elevated cockroach allergens and low concentrations of dust mite, cat, and dog allergens. Although the presence of an individual allergen is more likely associated with one or more socioeconomic or ethnic factors, most homes typically have multiple allergen burdens in excess of concentrations thought to be associated with sensitization and exacerbation of asthma. Mite and cockroach allergens have distinct and opposite associations with socioeconomic factors and population density. PMID:11940461

  13. Reliability and validity of the Dutch pediatric Voice Handicap Index.

    PubMed

    Veder, Laura; Pullens, Bas; Timmerman, Marieke; Hoeve, Hans; Joosten, Koen; Hakkesteegt, Marieke

    2017-05-01

    The pediatric voice handicap index (pVHI) has been developed to provide a better insight into the parents' perception of their child's voice related quality of life. The purpose of the present study was to validate the Dutch pVHI by evaluating its internal consistency and reliability. Furthermore, we determined the optimal cut-off point for a normal pVHI score. All items of the English pVHI were translated into Dutch. Parents of children in our dysphonic and control group were asked to fill out the questionnaire. For the test re-test analysis we used a different study group who filled out the pVHI twice as part of a large follow up study. Internal consistency was analyzed through Cronbach's α coefficient. The test-retest reliability was assessed by determining Pearson's correlation coefficient. Mann-Whitney test was used to compare the scores of the questionnaire of the control group with the dysphonic group. By calculating receiver operating characteristic (ROC) curves, sensitivity and specificity we were able to set a cut-off point. We obtained data from 122 asymptomatic children and from 79 dysphonic children. The scores of the questionnaire significantly differed between both groups. The internal consistency showed an overall Cronbach α coefficient of 0.96 and an excellent test-retest reliability of the total pVHI questionnaire with a Pearson's correlation coefficient of 0.90. A cut-off point for the total pVHI questionnaire was set at 7 points with a specificity of 85% and sensitivity of 100%. A cut-off point for the VAS score was set at 13 with a specificity of 93% and sensitivity of 97%. The Dutch pVHI is a valid and reliable tool for the assessment of children with voice problems. By setting a cut-off point for the score of the total pVHI questionnaire of 7 points and the VAS score of 13, the pVHI might be used as a screening tool to assess dysphonic complaints and the pVHI might be a useful and complementary tool to identify children with dysphonia. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Self Diagnostic Accelerometer for Mission Critical Health Monitoring of Aircraft and Spacecraft Engines

    NASA Technical Reports Server (NTRS)

    Lekki, John; Tokars, Roger; Jaros, Dave; Riggs, M. Terrence; Evans, Kenneth P.; Gyekenyesi, Andrew

    2009-01-01

    A self diagnostic accelerometer system has been shown to be sensitive to multiple failure modes of charge mode accelerometers. These failures include sensor structural damage, an electrical open circuit and most importantly sensor detachment. In this paper, experimental work that was performed to determine the capabilities of a self diagnostic accelerometer system while operating in the presence of various levels of mechanical noise, emulating real world conditions, is presented. The results show that the system can successfully conduct a self diagnostic routine under these conditions.

  15. Research and Development of Electrostatic Accelerometers for Space Science Missions at HUST.

    PubMed

    Bai, Yanzheng; Li, Zhuxi; Hu, Ming; Liu, Li; Qu, Shaobo; Tan, Dingyin; Tu, Haibo; Wu, Shuchao; Yin, Hang; Li, Hongyin; Zhou, Zebing

    2017-08-23

    High-precision electrostatic accelerometers have achieved remarkable success in satellite Earth gravity field recovery missions. Ultralow-noise inertial sensors play important roles in space gravitational wave detection missions such as the Laser Interferometer Space Antenna (LISA) mission, and key technologies have been verified in the LISA Pathfinder mission. Meanwhile, at Huazhong University of Science and Technology (HUST, China), a space accelerometer and inertial sensor based on capacitive sensors and the electrostatic control technique have also been studied and developed independently for more than 16 years. In this paper, we review the operational principle, application, and requirements of the electrostatic accelerometer and inertial sensor in different space missions. The development and progress of a space electrostatic accelerometer at HUST, including ground investigation and space verification are presented.

  16. Research and Development of Electrostatic Accelerometers for Space Science Missions at HUST

    PubMed Central

    Bai, Yanzheng; Li, Zhuxi; Hu, Ming; Liu, Li; Qu, Shaobo; Tan, Dingyin; Tu, Haibo; Wu, Shuchao; Yin, Hang; Li, Hongyin; Zhou, Zebing

    2017-01-01

    High-precision electrostatic accelerometers have achieved remarkable success in satellite Earth gravity field recovery missions. Ultralow-noise inertial sensors play important roles in space gravitational wave detection missions such as the Laser Interferometer Space Antenna (LISA) mission, and key technologies have been verified in the LISA Pathfinder mission. Meanwhile, at Huazhong University of Science and Technology (HUST, China), a space accelerometer and inertial sensor based on capacitive sensors and the electrostatic control technique have also been studied and developed independently for more than 16 years. In this paper, we review the operational principle, application, and requirements of the electrostatic accelerometer and inertial sensor in different space missions. The development and progress of a space electrostatic accelerometer at HUST, including ground investigation and space verification are presented. PMID:28832538

  17. A review of micromachined thermal accelerometers

    NASA Astrophysics Data System (ADS)

    Mukherjee, Rahul; Basu, Joydeep; Mandal, Pradip; Guha, Prasanta Kumar

    2017-12-01

    A thermal convection based micro-electromechanical accelerometer is a relatively new kind of acceleration sensor that does not require a solid proof mass, yielding unique benefits like high shock survival rating, low production cost, and integrability with CMOS integrated circuit technology. This article provides a comprehensive survey of the research, development, and current trends in the field of thermal acceleration sensors, with detailed enumeration on the theory, operation, modeling, and numerical simulation of such devices. Different reported varieties and structures of thermal accelerometers have been reviewed highlighting key design, implementation, and performance aspects. Materials and technologies used for fabrication of such sensors have also been discussed. Further, the advantages and challenges for thermal accelerometers vis-à-vis other prominent accelerometer types have been presented, followed by an overview of associated signal conditioning circuitry and potential applications.

  18. Accelerometry is associated with walking mobility, not physical activity, in persons with multiple sclerosis.

    PubMed

    Weikert, Madeline; Suh, Yoojin; Lane, Abbi; Sandroff, Brian; Dlugonski, Deirdre; Fernhall, Bo; Motl, Robert W

    2012-06-01

    Accelerometers are seemingly a criterion standard of real-life walking mobility and this is supported by assumptions and empirical data. This application would be strengthened by including objective measures of walking mobility along with a matched control sample for verifying specificity versus generality in accelerometer output. We compared associations among accelerometer output, walking mobility, and physical activity between persons with multiple sclerosis (MS) and controls without a neurological disorder. Sixty-six persons (33 MS, 33 matched controls) completed a battery of questionnaires, performed the six-minute walk (6MW) and timed-up-and-go (TUG), and wore an accelerometer for a 7-day period. After this period, participants completed the Godin Leisure-Time Exercise Questionnaire (GLTEQ) and International Physical Activity Questionnaire (IPAQ). Accelerometer output was significantly correlated with only mobility measures (6MW, ρ=.78; TUG, ρ=-.68) in MS, whereas it correlated with both mobility (6MW, ρ=.58; TUG, ρ=-.49) and physical activity (GLTEQ, ρ=.56; IPAQ, ρ=.53) measures in controls. Regression analysis indicated that only 6MW explained variance in accelerometer output in MS (β=.65, R(2)=.43). These findings support the possibility that accelerometers primarily and specifically measure real-life walking mobility, not physical activity, in persons with MS. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  19. Exploring the feasibility and use of acceleromters before, during, and after a camp-based CIMT program for children with cerebral palsy.

    PubMed

    Coker-Bolt, Patty; Downey, Ryan J; Connolly, Jacqueline; Hoover, Reagin; Shelton, Daniel; Seo, Na Jin

    2017-01-01

    The aim of this pilot study was to determine the feasibility and use accelerometers before, during, and after a camp-based constraint-induced movement therapy (CIMT) program for children with hemiplegic cerebral palsy. A pre-test post-test design was used for 12 children with CP (mean = 4.9 yrs) who completed a 30-hour camp-based CIMT program. The accelerometer data were collected using ActiGraph GT9X Link. Children wore accelerometers on both wrists one day before and after the camp and on the affected limb during each camp day. Three developmental assessments were administered pre-post CIMT program. Accelerometers were successfully worn before, during, and directly after the CIMT program to collect upper limb data. Affected upper limb accelerometer activity significantly increased during the CIMT camp compared to baseline (p< 0.05). Significant improvements were seen in all twelve children on all assessments of affected upper limb function (p< 0.05) measuring capacity and quality of affected upper limb functioning. Accelerometers can be worn during high intensity pediatric CIMT programs to collect data about affected upper limb function. Further study is required to determine the relationship between accelerometer data, measure of motor capacity, and real-world performance post-CIMT.

  20. Development of a High-Sensitivity Wireless Accelerometer for Structural Health Monitoring

    PubMed Central

    Zhu, Li; Fu, Yuguang; Chow, Raymond; Spencer, Billie F.; Park, Jong Woong; Mechitov, Kirill

    2018-01-01

    Structural health monitoring (SHM) is playing an increasingly important role in ensuring the safety of structures. A shift of SHM research away from traditional wired methods toward the use of wireless smart sensors (WSS) has been motivated by the attractive features of wireless smart sensor networks (WSSN). The progress achieved in Micro Electro-Mechanical System (MEMS) technologies and wireless data transmission, has extended the effectiveness and range of applicability of WSSNs. One of the most common sensors employed in SHM strategies is the accelerometer; however, most accelerometers in WSS nodes have inadequate resolution for measurement of the typical accelerations found in many SHM applications. In this study, a high-resolution and low-noise tri-axial digital MEMS accelerometer is incorporated in a next-generation WSS platform, the Xnode. In addition to meeting the acceleration sensing demands of large-scale civil infrastructure applications, this new WSS node provides powerful hardware and a robust software framework to enable edge computing that can deliver actionable information. Hardware and software integration challenges are presented, and the associate resolutions are discussed. The performance of the wireless accelerometer is demonstrated experimentally through comparison with high-sensitivity wired accelerometers. This new high-sensitivity wireless accelerometer will extend the use of WSSN to a broader class of SHM applications. PMID:29342102

  1. Development of a High-Sensitivity Wireless Accelerometer for Structural Health Monitoring.

    PubMed

    Zhu, Li; Fu, Yuguang; Chow, Raymond; Spencer, Billie F; Park, Jong Woong; Mechitov, Kirill

    2018-01-17

    Structural health monitoring (SHM) is playing an increasingly important role in ensuring the safety of structures. A shift of SHM research away from traditional wired methods toward the use of wireless smart sensors (WSS) has been motivated by the attractive features of wireless smart sensor networks (WSSN). The progress achieved in Micro Electro-Mechanical System (MEMS) technologies and wireless data transmission, has extended the effectiveness and range of applicability of WSSNs. One of the most common sensors employed in SHM strategies is the accelerometer; however, most accelerometers in WSS nodes have inadequate resolution for measurement of the typical accelerations found in many SHM applications. In this study, a high-resolution and low-noise tri-axial digital MEMS accelerometer is incorporated in a next-generation WSS platform, the Xnode. In addition to meeting the acceleration sensing demands of large-scale civil infrastructure applications, this new WSS node provides powerful hardware and a robust software framework to enable edge computing that can deliver actionable information. Hardware and software integration challenges are presented, and the associate resolutions are discussed. The performance of the wireless accelerometer is demonstrated experimentally through comparison with high-sensitivity wired accelerometers. This new high-sensitivity wireless accelerometer will extend the use of WSSN to a broader class of SHM applications.

  2. Effect of tool geometry and cutting parameters on delamination and thrust forces in drilling CFRP/Al-Li

    NASA Astrophysics Data System (ADS)

    El Bouami, Souhail; Habak, Malek; Franz, Gérald; Velasco, Raphaël; Vantomme, Pascal

    2016-10-01

    Composite materials are increasingly used for structural parts in the aeronautic industries. Carbon Fiber-Reinforced Plastics (CFRP) are often used in combination with metallic materials, mostly aluminium alloys. This raises new problems in aircraft assembly. Delamination is one of these problems. In this study, CFRP/Al-Li stacks is used as experimental material for investigation effect of interaction of cutting parameters (cutting speed and feed rate) and tool geometry on delamination and thrust forces in drilling operation. A plan of experiments, based on Taguchi design method, was employed to investigate the influence of tool geometry and in particular the point angle and cutting parameters on delamination and axial effort. The experimental results demonstrate that the feed rate is the major parameter and the importance of tool point angle in delamination and thrust forces in the stacks were shown.

  3. Experimental Investigation on Cutting Characteristics in Nanometric Plunge-Cutting of BK7 and Fused Silica Glasses

    PubMed Central

    An, Qinglong; Ming, Weiwei; Chen, Ming

    2015-01-01

    Ductile cutting are most widely used in fabricating high-quality optical glass components to achieve crack-free surfaces. For ultra-precision machining of brittle glass materials, critical undeformed chip thickness (CUCT) commonly plays a pivotal role in determining the transition point from ductile cutting to brittle cutting. In this research, cutting characteristics in nanometric cutting of BK7 and fused silica glasses, including machined surface morphology, surface roughness, cutting force and specific cutting energy, were investigated with nanometric plunge-cutting experiments. The same cutting speed of 300 mm/min was used in the experiments with single-crystal diamond tool. CUCT was determined according to the mentioned cutting characteristics. The results revealed that 320 nm was found as the CUCT in BK7 cutting and 50 nm was determined as the size effect of undeformed chip thickness. A high-quality machined surface could be obtained with the undeformed chip thickness between 50 and 320 nm at ductile cutting stage. Moreover, no CUCT was identified in fused silica cutting with the current cutting conditions, and brittle-fracture mechanism was confirmed as the predominant chip-separation mode throughout the nanometric cutting operation. PMID:28788010

  4. Experimental Investigation on Cutting Characteristics in Nanometric Plunge-Cutting of BK7 and Fused Silica Glasses.

    PubMed

    An, Qinglong; Ming, Weiwei; Chen, Ming

    2015-03-27

    Ductile cutting are most widely used in fabricating high-quality optical glass components to achieve crack-free surfaces. For ultra-precision machining of brittle glass materials, critical undeformed chip thickness (CUCT) commonly plays a pivotal role in determining the transition point from ductile cutting to brittle cutting. In this research, cutting characteristics in nanometric cutting of BK7 and fused silica glasses, including machined surface morphology, surface roughness, cutting force and specific cutting energy, were investigated with nanometric plunge-cutting experiments. The same cutting speed of 300 mm/min was used in the experiments with single-crystal diamond tool. CUCT was determined according to the mentioned cutting characteristics. The results revealed that 320 nm was found as the CUCT in BK7 cutting and 50 nm was determined as the size effect of undeformed chip thickness. A high-quality machined surface could be obtained with the undeformed chip thickness between 50 and 320 nm at ductile cutting stage. Moreover, no CUCT was identified in fused silica cutting with the current cutting conditions, and brittle-fracture mechanism was confirmed as the predominant chip-separation mode throughout the nanometric cutting operation.

  5. Cognitive and physical functions related to the level of supervision and dependence in the toileting of stroke patients.

    PubMed

    Sato, Atsushi; Okuda, Yutaka; Fujita, Takaaki; Kimura, Norihiko; Hoshina, Noriyuki; Kato, Sayaka; Tanaka, Shigenari

    2016-01-01

    This study aimed to clarify which cognitive and physical factors are associated with the need for toileting assistance in stroke patients and to calculate cut-off values for discriminating between independent supervision and dependent toileting ability. This cross-sectional study included 163 first-stroke patients in nine convalescent rehabilitation wards. Based on their FIM Ⓡ instrument score for toileting, the patients were divided into an independent-supervision group and a dependent group. Multiple logistic regression analysis and receiver operating characteristic analysis were performed to identify factors related to toileting performance. The Minimental State Examination (MMSE); the Stroke Impairment Assessment Set (SIAS) score for the affected lower limb, speech, and visuospatial functions; and the Functional Assessment for Control of Trunk (FACT) were analyzed as independent variables. The multiple logistic regression analysis showed that the FIM Ⓡ instrument score for toileting was associated with the SIAS score for the affected lower limb function, MMSE, and FACT. On receiver operating characteristic analysis, the SIAS score for the affected lower limb function cut-off value was 8/7 points, the MMSE cut-off value was 25/24 points, and the FACT cut-off value was 14/13 points. Affected lower limb function, cognitive function, and trunk function were related with the need for toileting assistance. These cut-off values may be useful for judging whether toileting assistance is needed in stroke patients.

  6. A novel gamma-fitting statistical method for anti-drug antibody assays to establish assay cut points for data with non-normal distribution.

    PubMed

    Schlain, Brian; Amaravadi, Lakshmi; Donley, Jean; Wickramasekera, Ananda; Bennett, Donald; Subramanyam, Meena

    2010-01-31

    In recent years there has been growing recognition of the impact of anti-drug or anti-therapeutic antibodies (ADAs, ATAs) on the pharmacokinetic and pharmacodynamic behavior of the drug, which ultimately affects drug exposure and activity. These anti-drug antibodies can also impact safety of the therapeutic by inducing a range of reactions from hypersensitivity to neutralization of the activity of an endogenous protein. Assessments of immunogenicity, therefore, are critically dependent on the bioanalytical method used to test samples, in which a positive versus negative reactivity is determined by a statistically derived cut point based on the distribution of drug naïve samples. For non-normally distributed data, a novel gamma-fitting method for obtaining assay cut points is presented. Non-normal immunogenicity data distributions, which tend to be unimodal and positively skewed, can often be modeled by 3-parameter gamma fits. Under a gamma regime, gamma based cut points were found to be more accurate (closer to their targeted false positive rates) compared to normal or log-normal methods and more precise (smaller standard errors of cut point estimators) compared with the nonparametric percentile method. Under a gamma regime, normal theory based methods for estimating cut points targeting a 5% false positive rate were found in computer simulation experiments to have, on average, false positive rates ranging from 6.2 to 8.3% (or positive biases between +1.2 and +3.3%) with bias decreasing with the magnitude of the gamma shape parameter. The log-normal fits tended, on average, to underestimate false positive rates with negative biases as large a -2.3% with absolute bias decreasing with the shape parameter. These results were consistent with the well known fact that gamma distributions become less skewed and closer to a normal distribution as their shape parameters increase. Inflated false positive rates, especially in a screening assay, shifts the emphasis to confirm test results in a subsequent test (confirmatory assay). On the other hand, deflated false positive rates in the case of screening immunogenicity assays will not meet the minimum 5% false positive target as proposed in the immunogenicity assay guidance white papers. Copyright 2009 Elsevier B.V. All rights reserved.

  7. Min-Cut Based Segmentation of Airborne LIDAR Point Clouds

    NASA Astrophysics Data System (ADS)

    Ural, S.; Shan, J.

    2012-07-01

    Introducing an organization to the unstructured point cloud before extracting information from airborne lidar data is common in many applications. Aggregating the points with similar features into segments in 3-D which comply with the nature of actual objects is affected by the neighborhood, scale, features and noise among other aspects. In this study, we present a min-cut based method for segmenting the point cloud. We first assess the neighborhood of each point in 3-D by investigating the local geometric and statistical properties of the candidates. Neighborhood selection is essential since point features are calculated within their local neighborhood. Following neighborhood determination, we calculate point features and determine the clusters in the feature space. We adapt a graph representation from image processing which is especially used in pixel labeling problems and establish it for the unstructured 3-D point clouds. The edges of the graph that are connecting the points with each other and nodes representing feature clusters hold the smoothness costs in the spatial domain and data costs in the feature domain. Smoothness costs ensure spatial coherence, while data costs control the consistency with the representative feature clusters. This graph representation formalizes the segmentation task as an energy minimization problem. It allows the implementation of an approximate solution by min-cuts for a global minimum of this NP hard minimization problem in low order polynomial time. We test our method with airborne lidar point cloud acquired with maximum planned post spacing of 1.4 m and a vertical accuracy 10.5 cm as RMSE. We present the effects of neighborhood and feature determination in the segmentation results and assess the accuracy and efficiency of the implemented min-cut algorithm as well as its sensitivity to the parameters of the smoothness and data cost functions. We find that smoothness cost that only considers simple distance parameter does not strongly conform to the natural structure of the points. Including shape information within the energy function by assigning costs based on the local properties may help to achieve a better representation for segmentation.

  8. Optimal Waist-to-Height Ratio Values for Cardiometabolic Risk Screening in an Ethnically Diverse Sample of South African Urban and Rural School Boys and Girls

    PubMed Central

    Matsha, Tandi E.; Kengne, Andre-Pascal; Yako, Yandiswa Y.; Hon, Gloudina M.; Hassan, Mogamat S.; Erasmus, Rajiv T.

    2013-01-01

    Background The proposed waist-to-height ratio (WHtR) cut-off of 0.5 is less optimal for cardiometabolic risk screening in children in many settings. The purpose of this study was to determine the optimal WHtR for children from South Africa, and investigate variations by gender, ethnicity and residence in the achieved value. Methods Metabolic syndrome (MetS) components were measured in 1272 randomly selected learners, aged 10–16 years, comprising of 446 black Africans, 696 mixed-ancestry and 130 Caucasians. The Youden’s index and the closest-top-left (CTL) point approaches were used to derive WHtR cut-offs for diagnosing any two MetS components, excluding the waist circumference. Results The two approaches yielded similar cut-off in girls, 0.465 (sensitivity 50.0, specificity 69.5), but two different values in boys, 0.455 (42.9, 88.4) and 0.425 (60.3, 67.7) based on the Youden’s index and the CTL point, respectively. Furthermore, WHtR cut-off values derived differed substantially amongst the regions and ethnic groups investigated, whereby the highest cut-off was observed in semi-rural and white children, respectively, Youden’s index0.505 (31.6, 87.1) and CTL point 0.475 (44.4, 75.9). Conclusion The WHtR cut-off of 0.5 is less accurate for screening cardiovascular risk in South African children. The optimal value in this setting is likely gender and ethnicity-specific and sensitive to urbanization. PMID:23967160

  9. Evaluation of Thermo-Mechanical Stability of COTS Dual-Axis MEMS Accelerometers for Space Applications

    NASA Technical Reports Server (NTRS)

    Sharma, Ashok K.; Teverovksy, Alexander; Day, John H. (Technical Monitor)

    2000-01-01

    Microelectromechanical systems in MEMS is one of the fastest growing technologies in microelectronics, and is of great interest for military and aerospace applications. Accelerometers are the earliest and most developed representatives of MEMS. First demonstrated in 1979, micromachined accelerometers were used in automobile industry for air bag crash- sensing applications since 1990. In 1999, N4EMS accelerometers were used in NASA-JPL Mars Microprobe. The most developed accelerometers for airbag crash- sensing are rated for a full range of +/- 50 G. The range of sensitivity for accelerometers required for military or aerospace applications is much larger, varying from 20,000 G (to measure acceleration during gun and ballistic munition launches), and to 10(exp -6) G, when used as guidance sensors (to measure attitude and position of a spacecraft). The presence of moving parts on the surface of chip is specific to MEMS, and particularly, to accelerometers. This characteristic brings new reliability issues to micromachined accelerometers, including cyclic fatigue cracking of polysilicon cantilevers and springs, mechanical stresses that are caused by packaging and contamination in the internal cavity of the package. Studies of fatigue cracks initiation and growth in polysilicon showed that the fatigue damage may influence MEMS device performance, and the presence of water vapor significantly enhances crack initiation and growth. Environmentally induced failures, particularly, failures due to thermal cycling and mechanical shock are considered as one of major reliability concerns in MEMS. These environmental conditions are also critical for space applications of the parts. For example, the Mars pathfinder mission had experienced 80 mechanical shock events during the pyrotechnic separation processes.

  10. Measurement of Impact Acceleration: Mouthpiece Accelerometer Versus Helmet Accelerometer

    PubMed Central

    Higgins, Michael; Halstead, P. David; Snyder-Mackler, Lynn; Barlow, David

    2007-01-01

    Context: Instrumented helmets have been used to estimate impact acceleration imparted to the head during helmet impacts. These instrumented helmets may not accurately measure the actual amount of acceleration experienced by the head due to factors such as helmet-to-head fit. Objective: To determine if an accelerometer attached to a mouthpiece (MP) provides a more accurate representation of headform center of gravity (HFCOG) acceleration during impact than does an accelerometer attached to a helmet fitted on the headform. Design: Single-factor research design in which the independent variable was accelerometer position (HFCOG, helmet, MP) and the dependent variables were g and Severity Index (SI). Setting: Independent impact research laboratory. Intervention(s): The helmeted headform was dropped (n = 168) using a National Operating Committee on Standards for Athletic Equipment (NOCSAE) drop system from the standard heights and impact sites according to NOCSAE test standards. Peak g and SI were measured for each accelerometer position during impact. Main Outcome Measures: Upon impact, the peak g and SI were recorded for each accelerometer location. Results: Strong relationships were noted for HFCOG and MP measures, and significant differences were seen between HFCOG and helmet g measures and HFCOG and helmet SI measures. No statistically significant differences were noted between HFCOG and MP g and SI measures. Regression analyses showed a significant relationship between HFCOG and MP measures but not between HFCOG and helmet measures. Conclusions: Upon impact, MP acceleration (g) and SI measurements were closely related to and more accurate in measuring HFCOG g and SI than helmet measurements. The MP accelerometer is a valid method for measuring head acceleration. PMID:17597937

  11. Modal Identification of Tsing MA Bridge by Using Improved Eigensystem Realization Algorithm

    NASA Astrophysics Data System (ADS)

    QIN, Q.; LI, H. B.; QIAN, L. Z.; LAU, C.-K.

    2001-10-01

    This paper presents the results of research work on modal identification of Tsing Ma bridge ambient testing data by using an improved eigensystem realization algorithm. The testing was carried out before the bridge was open to traffic and after the completion of surfacing. Without traffic load, ambient excitations were much less intensive, and the bridge responses to such ambient excitation were also less intensive. Consequently, the bridge responses were significantly influenced by the random movement of heavy construction vehicles on the deck. To cut off noises in the testing data and make the ambient signals more stationary, the Chebyshev digital filter was used instead of the digital filter with a Hanning window. Random decrement (RD) functions were built to convert the ambient responses to free vibrations. An improved eigensystem realization algorithm was employed to improve the accuracy and the efficiency of modal identification. It uses cross-correlation functions ofRD functions to form the Hankel matrix instead of RD functions themselves and uses eigenvalue decomposition instead of singular value decomposition. The data for response accelerations were acquired group by group because of limited number of high-quality accelerometers and channels of data loggers available. The modes were identified group by group and then assembled by using response accelerations acquired at reference points to form modes of the complete bridge. Seventy-nine modes of the Tsing Ma bridge were identified, including five complex modes formed in accordance with unevenly distributed damping in the bridge. The identified modes in time domain were then compared with those identified in frequency domain and finite element analytical results.

  12. Objectively measured physical activity of young Canadian children using accelerometry.

    PubMed

    Borkhoff, Cornelia M; Heale, Liane D; Anderson, Laura N; Tremblay, Mark S; Maguire, Jonathon L; Parkin, Patricia C; Birken, Catherine S

    2015-12-01

    The objective of the study was to describe objectively measured physical activity (PA) and sedentary time of infants, toddlers, and preschoolers and determine the proportion meeting Canadian age-specific PA guidelines. Ninety children (47 girls, 43 boys; mean age 32 (range, 4-70) months) attending scheduled health supervision visits and in the TARGet Kids! (The Applied Research Group for Kids) cohort wore an Actical accelerometer for 7 days. Participants with 4 or more valid days were included in the analysis. Time, in mean minutes per day (min/day), spent sedentary and in light PA, moderate to vigorous PA (MVPA), and total PA was determined using published cut-points; age groups were compared using ANOVA. Twenty-three percent of children <18 months (n = 28) and 76% of children aged 18-59 months (n = 45) met the guideline of 180 min/day of total PA; 13% of children ≥60 months (n = 17) met the guideline of 60 min/day of MVPA. Children <18 months spent more of their waking time per day engaged in sedentary behaviours (79%; ∼7.3 h) compared with children aged 18-59 months (63%; ∼6.6 h) and children ≥60 months (58%; ∼6.6 h). In conclusion, most children aged 18-59 months met the Canadian PA guidelines for children aged 0-4 years, whereas few younger than 18 months met the same guidelines. Only 13% of children ≥5 years met their age-specific PA guidelines. Further research is needed to develop, test, and implement effective strategies to promote PA and reduce sedentary behaviour in very young children.

  13. Measurement method of magnetic field for the wire suspended micro-pendulum accelerometer.

    PubMed

    Lu, Yongle; Li, Leilei; Hu, Ning; Pan, Yingjun; Ren, Chunhua

    2015-04-13

    Force producer is one of the core components of a Wire Suspended Micro-Pendulum Accelerometer; and the stability of permanent magnet in the force producer determines the consistency of the acceleration sensor's scale factor. For an assembled accelerometer; direct measurement of magnetic field strength is not a feasible option; as the magnetometer probe cannot be laid inside the micro-space of the sensor. This paper proposed an indirect measurement method of the remnant magnetization of Micro-Pendulum Accelerometer. The measurement is based on the working principle of the accelerometer; using the current output at several different scenarios to resolve the remnant magnetization of the permanent magnet. Iterative Least Squares algorithm was used for the adjustment of the data due to nonlinearity of this problem. The calculated remnant magnetization was 1.035 T. Compared to the true value; the error was less than 0.001 T. The proposed method provides an effective theoretical guidance for measuring the magnetic field of the Wire Suspended Micro-Pendulum Accelerometer; correcting the scale factor and temperature influence coefficients; etc.

  14. A digital output piezoelectric accelerometer using a Pb(Zr, Ti)O3 thin film array electrically connected in series

    NASA Astrophysics Data System (ADS)

    Kobayashi, T.; Okada, H.; Masuda, T.; Maeda, R.; Itoh, T.

    2010-10-01

    A digital output piezoelectric accelerometer is proposed to realize an ultra-low power consumption wireless sensor node. The accelerometer has patterned piezoelectric thin films (piezoelectric plates) electrically connected in series accompanied by CMOS switches at the end of some of the piezoelectric plates. The connected piezoelectric plates amplify the output voltage without the use of amplifiers. The CMOS switches turn on when the output voltage of the piezoelectric plates is higher than the CMOS threshold voltage. The piezoelectric accelerometer converts the acceleration into a number of on-state CMOS switches, which can be called the digital output. The proposed digital output piezoelectric accelerometer, using Pb(Zr, Ti)O3 (PZT) thin films as the piezoelectric material, was fabricated through a microelectromechanical system (MEMS) microfabrication process. The output voltage was found to be amplified by the number of connected piezoelectric plates. The DC output voltage obtained by using an AC to DC conversion circuit is proportional to the number of connections. The results show the potential for realizing the proposed digital output piezoelectric accelerometer.

  15. Cutting Force Predication Based on Integration of Symmetric Fuzzy Number and Finite Element Method

    PubMed Central

    Wang, Zhanli; Hu, Yanjuan; Wang, Yao; Dong, Chao; Pang, Zaixiang

    2014-01-01

    In the process of turning, pointing at the uncertain phenomenon of cutting which is caused by the disturbance of random factors, for determining the uncertain scope of cutting force, the integrated symmetric fuzzy number and the finite element method (FEM) are used in the prediction of cutting force. The method used symmetric fuzzy number to establish fuzzy function between cutting force and three factors and obtained the uncertain interval of cutting force by linear programming. At the same time, the change curve of cutting force with time was directly simulated by using thermal-mechanical coupling FEM; also the nonuniform stress field and temperature distribution of workpiece, tool, and chip under the action of thermal-mechanical coupling were simulated. The experimental result shows that the method is effective for the uncertain prediction of cutting force. PMID:24790556

  16. An adaptive technique for estimating the atmospheric density profile during the AE mission

    NASA Technical Reports Server (NTRS)

    Argentiero, P.

    1973-01-01

    A technique is presented for processing accelerometer data obtained during the AE missions in order to estimate the atmospheric density profile. A minimum variance, adaptive filter is utilized. The trajectory of the probe and probe parameters are in a consider mode where their estimates are unimproved but their associated uncertainties are permitted an impact on filter behavior. Simulations indicate that the technique is effective in estimating a density profile to within a few percentage points.

  17. Insulin sensitivity indices: a proposal of cut-off points for simple identification of insulin-resistant subjects.

    PubMed

    Radikova, Z; Koska, J; Huckova, M; Ksinantova, L; Imrich, R; Vigas, M; Trnovec, T; Langer, P; Sebokova, E; Klimes, I

    2006-05-01

    Demanding measurement of insulin sensitivity using clamp methods does not simplify the identification of insulin resistant subjects in the general population. Other approaches such as fasting- or oral glucose tolerance test-derived insulin sensitivity indices were proposed and validated with the euglycemic clamp. Nevertheless, a lack of reference values for these indices prevents their wider use in epidemiological studies and clinical practice. The aim of our study was therefore to define the cut-off points of insulin resistance indices as well as the ranges of the most frequently obtained values for selected indices. A standard 75 g oral glucose tolerance test was carried out in 1156 subjects from a Caucasian rural population with no previous evidence of diabetes or other dysglycemias. Insulin resistance/sensitivity indices (HOMA-IR, HOMA-IR2, ISI Cederholm, and ISI Matsuda) were calculated. The 75th percentile value as the cut-off point to define IR corresponded with a HOMA-IR of 2.29, a HOMA-IR2 of 1.21, a 25th percentile for ISI Cederholm, and ISI Matsuda of 57 and 5.0, respectively. For the first time, the cut-off points for selected indices and their most frequently obtained values were established for groups of subjects as defined by glucose homeostasis and BMI. Thus, insulin-resistant subjects can be identified using this simple approach.

  18. Effect of Cut Quality on Hybrid Laser Arc Welding of Thick Section Steels

    NASA Astrophysics Data System (ADS)

    Farrokhi, F.; Nielsen, S. E.; Schmidt, R. H.; Pedersen, S. S.; Kristiansen, M.

    From an industrial point of view, in a laser cutting-welding production chain, it is of great importance to know the influence of the attainable laser cut quality on the subsequent hybrid laser arc welding process. Many studies have been carried out in the literature to obtain lower surface roughness values on the laser cut edge. However, in practice, the cost and reliability of the cutting process is crucial and it does not always comply with obtaining the highest surface quality. In this study, a number of experiments on 25 mm steel plates were carried out to evaluate the influence of cut surface quality on the final quality of the subsequent hybrid laser welded joints. The different cut surfaces were obtained by different industrial cutting methods including laser cutting, abrasive water cutting, plasma cutting, and milling. It was found that the mentioned cutting methods could be used as preparation processes for the subsequent hybrid laser arc welding. However, cut quality could determine the choice of process parameters of the following hybrid laser arc welding.

  19. Estimates of success in patients with sciatica due to lumbar disc herniation depend upon outcome measure.

    PubMed

    Haugen, Anne Julsrud; Grøvle, Lars; Brox, Jens Ivar; Natvig, Bård; Keller, Anne; Soldal, Dag; Grotle, Margreth

    2011-10-01

    The objectives were to estimate the cut-off points for success on different sciatica outcome measures and to determine the success rate after an episode of sciatica by using these cut-offs. A 12-month multicenter observational study was conducted on 466 patients with sciatica and lumbar disc herniation. The cut-off values were estimated by ROC curve analyses using Completely recovered or Much better on a 7-point global change scale as external criterion for success. The cut-off values (references in brackets) at 12 months were leg pain VAS 17.5 (0-100), back pain VAS 22.5 (0-100), Sciatica Bothersomeness Index 6.5 (0-24), Maine-Seattle Back Questionnaire 4.5 (0-12), and the SF-36 subscales bodily pain 51.5, and physical functioning 81.7 (0-100, higher values indicate better health). In conclusion, the success rates at 12 months varied from 49 to 58% depending on the measure used. The proposed cut-offs may facilitate the comparison of success rates across studies.

  20. A Cutting Pattern Recognition Method for Shearers Based on Improved Ensemble Empirical Mode Decomposition and a Probabilistic Neural Network

    PubMed Central

    Xu, Jing; Wang, Zhongbin; Tan, Chao; Si, Lei; Liu, Xinhua

    2015-01-01

    In order to guarantee the stable operation of shearers and promote construction of an automatic coal mining working face, an online cutting pattern recognition method with high accuracy and speed based on Improved Ensemble Empirical Mode Decomposition (IEEMD) and Probabilistic Neural Network (PNN) is proposed. An industrial microphone is installed on the shearer and the cutting sound is collected as the recognition criterion to overcome the disadvantages of giant size, contact measurement and low identification rate of traditional detectors. To avoid end-point effects and get rid of undesirable intrinsic mode function (IMF) components in the initial signal, IEEMD is conducted on the sound. The end-point continuation based on the practical storage data is performed first to overcome the end-point effect. Next the average correlation coefficient, which is calculated by the correlation of the first IMF with others, is introduced to select essential IMFs. Then the energy and standard deviation of the reminder IMFs are extracted as features and PNN is applied to classify the cutting patterns. Finally, a simulation example, with an accuracy of 92.67%, and an industrial application prove the efficiency and correctness of the proposed method. PMID:26528985

  1. A PFC3D-based numerical simulation of cutting load for lunar rock simulant and experimental validation

    NASA Astrophysics Data System (ADS)

    Li, Peng; Jiang, Shengyuan; Tang, Dewei; Xu, Bo

    2017-05-01

    For sake of striking a balance between the need of drilling efficiency and the constrains of power budget on the moon, the penetrations per revolution of drill bit are generally limited in the range around 0.1 mm, and besides the geometric angle of the cutting blade need to be well designed. This paper introduces a simulation approach based on PFC3D (particle flow code 3 dimensions) for analyzing the cutting load feature on lunar rock simulant, which is derived from different geometric-angle blades with a small cutting depth. The mean values of the cutting force of five blades in the survey region (four on the boundary points and one on the center point) are selected as the macroscopic responses of model. The method of experimental design which includes Plackett-Burman (PB) design and central composite design (CCD) method is adopted in the matching procedure of microparameters in PFC model. Using the optimization method of enumeration, the optimum set of microparameters is acquired. Then, the experimental validation is implemented by using other twenty-five blades with different geometric angles, and the results from both simulations and laboratory tests give fair agreements. Additionally, the rock breaking process cut by different blades are quantified from simulation analysis. This research provides the theoretical support for the refinement of the rock cutting load prediction and the geometric design of cutting blade on the drill bit.

  2. Study on Misalignment Angle Compensation during Scale Factor Matching for Two Pairs of Accelerometers in a Gravity Gradient Instrument

    PubMed Central

    Huang, Xiangqing; Deng, Zhongguang; Xie, Yafei; Fan, Ji; Hu, Chenyuan

    2018-01-01

    A method for automatic compensation of misalignment angles during matching the scale factors of two pairs of the accelerometers in developing the rotating accelerometer gravity gradient instrument (GGI) is proposed and demonstrated in this paper. The purpose of automatic scale factor matching of the four accelerometers in GGI is to suppress the common mode acceleration of the moving-based platforms. However, taking the full model equation of the accelerometer into consideration, the other two orthogonal axes which is the pendulous axis and the output axis, will also sense the common mode acceleration and reduce the suppression performance. The coefficients from the two axes to the output are δO and δP respectively, called the misalignment angles. The angle δO, coupling with the acceleration along the pendulous axis perpendicular to the rotational plane, will not be modulated by the rotation and gives little contribution to the scale factors matching. On the other hand, because of coupling with the acceleration along the centripetal direction in the rotating plane, the angle δP would produce a component with 90 degrees phase delay relative to the scale factor component. Hence, the δP component coincides exactly with the sensitive direction of the orthogonal accelerometers. To improve the common mode acceleration rejection, the misalignment angle δP is compensated by injecting a trimming current, which is proportional to the output of an orthogonal accelerometer, into the torque coil of the accelerometer during the scale factor matching. The experimental results show that the common linear acceleration suppression achieved three orders after the scale factors balance and five orders after the misalignment angles compensation, which is almost down to the noise level of the used accelerometers of 1~2 × 10−7 g/√Hz (1 g ≈ 9.8 m/s2). PMID:29670021

  3. Is questionnaire-based sitting time inaccurate and can it be improved? A cross-sectional investigation using accelerometer-based sitting time.

    PubMed

    Gupta, Nidhi; Christiansen, Caroline Stordal; Hanisch, Christiana; Bay, Hans; Burr, Hermann; Holtermann, Andreas

    2017-01-16

    To investigate the differences between a questionnaire-based and accelerometer-based sitting time, and develop a model for improving the accuracy of questionnaire-based sitting time for predicting accelerometer-based sitting time. 183 workers in a cross-sectional study reported sitting time per day using a single question during the measurement period, and wore 2 Actigraph GT3X+ accelerometers on the thigh and trunk for 1-4 working days to determine their actual sitting time per day using the validated Acti4 software. Least squares regression models were fitted with questionnaire-based siting time and other self-reported predictors to predict accelerometer-based sitting time. Questionnaire-based and accelerometer-based average sitting times were ≈272 and ≈476 min/day, respectively. A low Pearson correlation (r=0.32), high mean bias (204.1 min) and wide limits of agreement (549.8 to -139.7 min) between questionnaire-based and accelerometer-based sitting time were found. The prediction model based on questionnaire-based sitting explained 10% of the variance in accelerometer-based sitting time. Inclusion of 9 self-reported predictors in the model increased the explained variance to 41%, with 10% optimism using a resampling bootstrap validation. Based on a split validation analysis, the developed prediction model on ≈75% of the workers (n=132) reduced the mean and the SD of the difference between questionnaire-based and accelerometer-based sitting time by 64% and 42%, respectively, in the remaining 25% of the workers. This study indicates that questionnaire-based sitting time has low validity and that a prediction model can be one solution to materially improve the precision of questionnaire-based sitting time. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. Study on Misalignment Angle Compensation during Scale Factor Matching for Two Pairs of Accelerometers in a Gravity Gradient Instrument.

    PubMed

    Huang, Xiangqing; Deng, Zhongguang; Xie, Yafei; Fan, Ji; Hu, Chenyuan; Tu, Liangcheng

    2018-04-18

    A method for automatic compensation of misalignment angles during matching the scale factors of two pairs of the accelerometers in developing the rotating accelerometer gravity gradient instrument (GGI) is proposed and demonstrated in this paper. The purpose of automatic scale factor matching of the four accelerometers in GGI is to suppress the common mode acceleration of the moving-based platforms. However, taking the full model equation of the accelerometer into consideration, the other two orthogonal axes which is the pendulous axis and the output axis, will also sense the common mode acceleration and reduce the suppression performance. The coefficients from the two axes to the output are δ O and δ P respectively, called the misalignment angles. The angle δ O , coupling with the acceleration along the pendulous axis perpendicular to the rotational plane, will not be modulated by the rotation and gives little contribution to the scale factors matching. On the other hand, because of coupling with the acceleration along the centripetal direction in the rotating plane, the angle δ P would produce a component with 90 degrees phase delay relative to the scale factor component. Hence, the δ P component coincides exactly with the sensitive direction of the orthogonal accelerometers. To improve the common mode acceleration rejection, the misalignment angle δ P is compensated by injecting a trimming current, which is proportional to the output of an orthogonal accelerometer, into the torque coil of the accelerometer during the scale factor matching. The experimental results show that the common linear acceleration suppression achieved three orders after the scale factors balance and five orders after the misalignment angles compensation, which is almost down to the noise level of the used accelerometers of 1~2 × 10 −7 g/√Hz (1 g ≈ 9.8 m/s²).

  5. Estimation of the auto frequency response function at unexcited points using dummy masses

    NASA Astrophysics Data System (ADS)

    Hosoya, Naoki; Yaginuma, Shinji; Onodera, Hiroshi; Yoshimura, Takuya

    2015-02-01

    If structures with complex shapes have space limitations, vibration tests using an exciter or impact hammer for the excitation are difficult. Although measuring the auto frequency response function at an unexcited point may not be practical via a vibration test, it can be obtained by assuming that the inertia acting on a dummy mass is an external force on the target structure upon exciting a different excitation point. We propose a method to estimate the auto frequency response functions at unexcited points by attaching a small mass (dummy mass), which is comparable to the accelerometer mass. The validity of the proposed method is demonstrated by comparing the auto frequency response functions estimated at unexcited points in a beam structure to those obtained from numerical simulations. We also consider random measurement errors by finite element analysis and vibration tests, but not bias errors. Additionally, the applicability of the proposed method is demonstrated by applying it to estimate the auto frequency response function of the lower arm in a car suspension.

  6. A comprehensive comparison of simple step counting techniques using wrist- and ankle-mounted accelerometer and gyroscope signals.

    PubMed

    Rhudy, Matthew B; Mahoney, Joseph M

    2018-04-01

    The goal of this work is to compare the differences between various step counting algorithms using both accelerometer and gyroscope measurements from wrist and ankle-mounted sensors. Participants completed four different conditions on a treadmill while wearing an accelerometer and gyroscope on the wrist and the ankle. Three different step counting techniques were applied to the data from each sensor type and mounting location. It was determined that using gyroscope measurements allowed for better performance than the typically used accelerometers, and that ankle-mounted sensors provided better performance than those mounted on the wrist.

  7. An Accelerometer as an Alternative to a Force Plate for the Step-Up-and-Over Test.

    PubMed

    Bailey, Christopher A; Costigan, Patrick A

    2015-12-01

    The step-up-and-over test has been used successfully to examine knee function after knee injury. Knee function is quantified using the following variables extracted from force plate data: the maximal force exerted during the lift, the maximal impact force at landing, and the total time to complete the step. For various reasons, including space and cost, it is unlikely that all clinicians will have access to a force plate. The purpose of the study was to determine if the step-up-and-over test could be simplified by using an accelerometer. The step-up-and-over test was performed by 17 healthy young adults while being measured with both a force plate and a 3-axis accelerometer mounted at the low back. Results showed that the accelerometer and force plate measures were strongly correlated for all 3 variables (r = .90-.98, Ps < .001) and that the accelerometer values for the lift and impact indices were 6-7% higher (Ps < .01) and occurred 0.07-0.1 s later than the force plate (Ps < .05). The accelerometer returned values highly correlated to those from a force plate. Compared with a force plate, a wireless, 3-axis accelerometer is a less expensive and more portable system with which to measure the step-up-and-over test.

  8. Mechanical design of a single-axis monolithic accelerometer for advanced seismic attenuation systems

    NASA Astrophysics Data System (ADS)

    Bertolini, Alessandro; DeSalvo, Riccardo; Fidecaro, Francesco; Francesconi, Mario; Marka, Szabolcs; Sannibale, Virginio; Simonetti, Duccio; Takamori, Akiteru; Tariq, Hareem

    2006-01-01

    The design and mechanics for a new very-low noise low frequency horizontal accelerometer is presented. The sensor has been designed to be integrated in an advanced seismic isolation system for interferometric gravitational wave detectors. The motion of a small monolithic folded-pendulum (FP) is monitored by a high resolution capacitance displacement sensor; a feedback force actuator keeps the mass at the equilibrium position. The feedback signal is proportional to the ground acceleration in the frequency range 0-150 Hz. The very high mechanical quality factor, Q≃3000 at a resonant frequency of 0.5 Hz, reduces the Brownian motion of the proof mass of the accelerometer below the resolution of the displacement sensor. This scheme enables the accelerometer to detect the inertial displacement of a platform with a root-mean-square noise less than 1 nm, integrated over the frequency band from 0.01 to 150 Hz. The FP geometry, combined with the monolithic design, allows the accelerometer to be extremely directional. A vertical-horizontal coupling ranging better than 10-3 has been achieved. A detailed account of the design and construction of the accelerometer is reported here. The instrument is fully ultra-high vacuum compatible and has been tested and approved for integration in seismic attenuation system of japanese TAMA 300 gravitational wave detector. The monolithic design also makes the accelerometer suitable for cryogenic operation.

  9. Physical activity and sedentary behavior during pregnancy and postpartum, measured using hip and wrist-worn accelerometers.

    PubMed

    Hesketh, Kathryn R; Evenson, Kelly R; Stroo, Marissa; Clancy, Shayna M; Østbye, Truls; Benjamin-Neelon, Sara E

    2018-06-01

    Physical activity in pregnancy and postpartum is beneficial to mothers and infants. To advance knowledge of objective physical activity measurement during these periods, this study compares hip to wrist accelerometer compliance; assesses convergent validity (correlation) between hip- and wrist-worn accelerometry; and assesses change in physical activity from pregnancy to postpartum. We recruited women during pregnancy ( n  = 100; 2014-2015), asking them to wear hip and wrist accelerometers for 7 days during Trimester 2 (T2), Trimester 3 (T3), and 3-, 6-, 9- and 12-months postpartum. We assessed average wear-time and correlations (axis-specific counts/minute, vector magnitude counts/day and step counts/day) at T2, T3, and postpartum. Compliance was higher for wrist-worn accelerometers. Hip and wrist accelerometers showed moderate to high correlations (Pearson's r 0.59 to 0.84). Hip-measured sedentary and active time differed little between T2 and T3. Moderate-to-vigorous physical activity decreased at T3 and remained low postpartum. Light physical activity increased and sedentary time decreased throughout the postpartum period. Wrist accelerometers may be preferable during pregnancy and appear comparable to hip accelerometers. As physical activity declines during later pregnancy and may not rebound post birth, support for re-engaging in physical activity earlier in the postpartum period may benefit women.

  10. [Significance of 2-hour blood glucose after standardized steamed bread meal in diabetic screening].

    PubMed

    Liu, Yongquan; Tian, Hui; Fang, Fusheng; Xiao, Haiying; Lu, Yanhui; Shao, Yinghong; Li, Chunlin

    2014-05-13

    To explore the significance of 2-hour blood glucose after standardized steamed bread meal (SB-2 hBG) in diabetic screening. A retrospective study was conducted for diabetic screening data of annual check-up at PLA General Hospital from May 1996 to June 2002. And 100 g standardized steamed bread meal test was performed for non-diabetic subjects. Those subjects with SB-2 h BG ≥ 7.2 mmol/L underwent a 75 g oral glucose tolerance test (OGTT) within 2 weeks to determine whether the diagnosis of diabetes mellitus (DM) could be established (WHO, 1985, 1999, Diagnostic Criteria for Diabetes). By extracting the data for 7 consecutive years, we analyzed the significance and the cut-off point of SB-2 hBG in the diagnosis of DM and investigated the changes of blood glucose curves in different glucose tolerance status after different glucose loading tests. A total of 3 343 subjects with complete information were recruited. There were 3 101 males and 242 females with an age range of 40-94 years. According to the results of OGTT, 429 (12.8%) subjects were diagnosed as DM, 1 405 (42.1%) were diagnosed as impaired glucose regulation (IGR) and 1 509(45.1%) had normal glucose tolerance (NGT).With a deterioration of glucose tolerance status, the difference between SB-2 hBG and OGTT-2 hBG increased gradually in 3 group (P < 0.01), namely the NGT group 1.7 (0.8-2.8) mmol/L, IGR group -0.4 (-1.2-0.6) mmol/L, DM group -2.7(-3.8-1.1) mmol/L. The cut-off points of FBG for the diagnosis of IGR and DM were 5.3 (sensitivity of 46.2%, specificity of 68.5%) and 5.6 (sensitivity of 57.4%, specificity of 76.4%) mmol/L respectively. The cut-off points of SB-2 h BG were 8.2 mmol/L for the diagnosis of IGR (sensitivity of 63.8%, specificity of 59.9%) and 9.2 mmol/L for the diagnosis of DM (sensitivity of 66.4%, specificity of 76.4%).If the cut-off point of SB-2 h BG was set at 7.2 mmol/L, the diagnostic specificity became quite low.However, at 11.1 mmol/L, the sensitivity was 31.5% and the specificity 95.7% for the diagnosis of DM. The coincidences of cut-off points of FBG and SB-2 hBG for the diagnosis of IGR and DM were equal (P > 0.05).When the cut-off point of SB-2 h BG was set at 7.8 mmol/L, the sensitivity was 77.4% and the specificity 41.8% for the diagnosis of IGR. And it was much better than FBG at 5.6 mmol/L (P < 0.01). With a deterioration of glucose tolerance, the difference between SB-2 hBG and OGTT-2 hBG increases gradually. Compared to the diagnostic criteria of OGTT, the optimal cut-off points for the diagnosis of IGR and DM were 5.3 vs 5.6 mmol/L for FBG and 8.2 vs 9.2 mmol/L for SB-2 hBG respectively.For diabetic screening in middle-aged and elders, the cut-off points of FBG at 5.3 mmol/L and SB-2 hBG at 7.8 mmol/L are indicators for further OGTT.

  11. 6. SEAWARD VIEW OF BOAT LANDING CUT INTO ROCK, ALSO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. SEAWARD VIEW OF BOAT LANDING CUT INTO ROCK, ALSO SHOWING CEMENT POURED ATOP TUNNEL. - Mile Rock Tunnel, Under Forty-eighth Avenue from Cabrillo Street to San Francisco Bay at Point Lobos, San Francisco, San Francisco County, CA

  12. Comparison of two cut-to-length harvesting systems operating in eastern hardwoods

    Treesearch

    Chris B. LeDoux; Niel K. Huyler

    2001-01-01

    We compared production rates, operating costs, and break-even points (BEP) for small and large cut-to-length (CTL) harvesting systems operating at several machine utilization rates (MUR) in mixed hardwood and softwood stands in Vermont.

  13. The role of serum transferrin receptor in the diagnosis of iron deficiency.

    PubMed

    Remacha, A F; Sarda, M P; Parellada, M; Ubeda, J; Manteiga, R

    1998-11-01

    Iron deficiency anemia (IDA) is often associated with inflammatory disorders. The most conventional parameters of iron metabolism are therefore affected, making the evaluation of iron status difficult. Serum transferrin receptor (sTfR) levels are raised in iron deficiency but are not influenced by inflammatory changes. The aim of this study was to investigate the role of sTfR in differentiating IDA with inflammatory features. A diagnostic study of sTfR measured by immunoassay was carried out in IDA and anemia of chronic disorders (ACD). The cut-off points of sTfR and the ratio of sTfR/serum ferritin, which were obtained after comparing IDA and ACD, were applied to a group of 64 patients with mixed iron patterns (MIX) (16 with ACD and 48 with IDA). The best cut-off point of sTfR between IDA and ACD was 4.7 mg/L. Applying this cut-off to the MIX group, an efficiency of 87% was obtained (sensitivity 92% and specificity 81%). This level of sTfR correctly classified 53 out of 64 cases of the MIX group (83%). Using the ratio of sTfRx 100/serum ferritin, the best cut-off point was 8 (efficiency 100%), which correctly classified 62 out of 64 cases of the MIX group (97%). This study demonstrates that sTfR in conjunction with other iron parameters is very useful in iron deficiency evaluation, especially in hospital practice. Iron treatment should be considered in patients with mixed patterns of iron status, in which the diagnosis of IDA versus ACD is difficult, when the levels of sTfR exceed the cut-off point.

  14. Validity of the Enzyme-linked Immunoelectrotransfer Blot (EITB) for naturally acquired porcine cysticercosis

    PubMed Central

    Jayashi, César M.; Gonzalez, Armando E.; Neyra, Ricardo Castillo; Rodríguez, Silvia; García, Hector H.; Lightowlers, Marshall W.

    2017-01-01

    The Enzyme-linked Immunoelectrotransfer Blot (EITB) has been used widely as a screening test for Taenia solium cysticercosis in swine. However, the relation between seropositivity and infection in pig populations from endemic areas has not been well defined. The aim of this study is to relate EITB seropositivity with infection and infection burden, analyse the trade-off between sensitivity and specificity with various cut-off points for the EITB assay, and finally describe the serology changes in a cohort of rural pigs raised under natural conditions. A group of 107 pigs that were used as controls during a vaccination field trial in Peru was our study population. The prevalence of porcine cysticercosis determined by necropsy examination was 16.82% (18/107) in these animals. Using EITB reactivity to ≥ 1 band as a cut-off point for the assay, the sensitivity was 88.89% (65.29-98.62, 95% CI) and the specificity was 48.31% (37.59-59.16, 95% CI). Comparing other cut-off points, involving up to as many as 7 reactive bands, a reactivity of ≥ 3 bands provided the best trade-offs in sensitivity and specificity. Using this cut-off point for the assay, the sensitivity was 77.77% (52.36 - 93.59, 95% CI) and the specificity was 76.40% (66.22 - 84.76, 95% CI). A significant association was found between cyst counts over 100 cysts and reactivity to ≥ 3 bands in the EITB assay (Fisher’s exact test, p<0.05). The results of this study suggest that the use of the EITB assay to study porcine cysticercosis may require setting different cut-offs under field and experimental conditions, and depending upon the objective of the screening process. PMID:24183647

  15. The diagnostic value of the numeric pain rating scale in older postoperative patients.

    PubMed

    van Dijk, Jacqueline F M; Kappen, Teus H; van Wijck, Albert J M; Kalkman, Cor J; Schuurmans, Marieke J

    2012-11-01

    To measure the diagnostic value of the Numeric Rating Scale by comparing it to a Verbal Rating Scale in older patients. Pain management in older patients is an important challenge because of their greater susceptibility to adverse effects of analgesics. Nurses play an important role in applying guidelines for postoperative pain treatment. However, effective pain management is dependent upon valid and reliable pain assessment. Cross-sectional study. In total, 2674 older patients scored their postoperative pain on an 11-point numeric rating scale (NRS) and an adjective scale (VRS) including no pain, little pain, painful but bearable, considerable pain and terrible pain. The diagnostic value of different NRS cut-off values for administering analgesics is determined by an ROC curve. Sensitivity of NRS > 3 for 'unbearable' pain in older patients was 72% with a specificity of 97·2%. With a cut-off point NRS > 4, sensitivity increased to 83%, while specificity was 96·7%. With a cut-off point NRS > 5, sensitivity was 94%, while specificity was 85%. A high proportion (75%) of older old patients (≥ 75 years) with 'painful but bearable' considers NRS 4, 5 and 6 to this VRS category. Using an NRS cut-off point > 3 or > 4, a large group of older patients with 'bearable' pain would incorrectly classified as 'unbearable'. When we make the assumption that bearable pain means no wish for additional analgesics, this misclassification might result in overtreatment with analgesics, while 3% would be undertreated. With NRS cut-off point > 5, 6% have a risk of overtreatment and 15% of undertreatment. Nurses should not rely solely on the NRS score in determining pain treatment; they need to communicate with older patients about their pain, the need for analgesics and eventual misconceptions about analgesics. © 2012 Blackwell Publishing Ltd.

  16. Optimal Cut-Off Points of Fasting Plasma Glucose for Two-Step Strategy in Estimating Prevalence and Screening Undiagnosed Diabetes and Pre-Diabetes in Harbin, China

    PubMed Central

    Sun, Bo; Lan, Li; Cui, Wenxiu; Xu, Guohua; Sui, Conglan; Wang, Yibaina; Zhao, Yashuang; Wang, Jian; Li, Hongyuan

    2015-01-01

    To identify optimal cut-off points of fasting plasma glucose (FPG) for two-step strategy in screening abnormal glucose metabolism and estimating prevalence in general Chinese population. A population-based cross-sectional study was conducted on 7913 people aged 20 to 74 years in Harbin. Diabetes and pre-diabetes were determined by fasting and 2 hour post-load glucose from the oral glucose tolerance test in all participants. Screening potential of FPG, cost per case identified by two-step strategy, and optimal FPG cut-off points were described. The prevalence of diabetes was 12.7%, of which 65.2% was undiagnosed. Twelve percent or 9.0% of participants were diagnosed with pre-diabetes using 2003 ADA criteria or 1999 WHO criteria, respectively. The optimal FPG cut-off points for two-step strategy were 5.6 mmol/l for previously undiagnosed diabetes (area under the receiver-operating characteristic curve of FPG 0.93; sensitivity 82.0%; cost per case identified by two-step strategy ¥261), 5.3 mmol/l for both diabetes and pre-diabetes or pre-diabetes alone using 2003 ADA criteria (0.89 or 0.85; 72.4% or 62.9%; ¥110 or ¥258), 5.0 mmol/l for pre-diabetes using 1999 WHO criteria (0.78; 66.8%; ¥399), and 4.9 mmol/l for IGT alone (0.74; 62.2%; ¥502). Using the two-step strategy, the underestimates of prevalence reduced to nearly 38% for pre-diabetes or 18.7% for undiagnosed diabetes, respectively. Approximately a quarter of the general population in Harbin was in hyperglycemic condition. Using optimal FPG cut-off points for two-step strategy in Chinese population may be more effective and less costly for reducing the missed diagnosis of hyperglycemic condition. PMID:25785585

  17. Benchmark Dose for Urinary Cadmium based on a Marker of Renal Dysfunction: A Meta-Analysis

    PubMed Central

    Woo, Hae Dong; Chiu, Weihsueh A.; Jo, Seongil; Kim, Jeongseon

    2015-01-01

    Background Low doses of cadmium can cause adverse health effects. Benchmark dose (BMD) and the one-sided 95% lower confidence limit of BMD (BMDL) to derive points of departure for urinary cadmium exposure have been estimated in several previous studies, but the methods to derive BMD and the estimated BMDs differ. Objectives We aimed to find the associated factors that affect BMD calculation in the general population, and to estimate the summary BMD for urinary cadmium using reported BMDs. Methods A meta-regression was performed and the pooled BMD/BMDL was estimated using studies reporting a BMD and BMDL, weighted by sample size, that were calculated from individual data based on markers of renal dysfunction. Results BMDs were highly heterogeneous across studies. Meta-regression analysis showed that a significant predictor of BMD was the cut-off point which denotes an abnormal level. Using the 95th percentile as a cut off, BMD5/BMDL5 estimates for 5% benchmark responses (BMR) of β2-microglobulinuria (β2-MG) estimated was 6.18/4.88 μg/g creatinine in conventional quantal analysis and 3.56/3.13 μg/g creatinine in the hybrid approach, and BMD5/BMDL5 estimates for 5% BMR of N-acetyl-β-d-glucosaminidase (NAG) was 10.31/7.61 μg/g creatinine in quantal analysis and 3.21/2.24 g/g creatinine in the hybrid approach. However, the meta-regression showed that BMD and BMDL were significantly associated with the cut-off point, but BMD calculation method did not significantly affect the results. The urinary cadmium BMDL5 of β2-MG was 1.9 μg/g creatinine in the lowest cut-off point group. Conclusion The BMD was significantly associated with the cut-off point defining the abnormal level of renal dysfunction markers. PMID:25970611

  18. An optimal cut-off point for the calving interval may be used as an indicator of bovine abortions.

    PubMed

    Bronner, Anne; Morignat, Eric; Gay, Emilie; Calavas, Didier

    2015-10-01

    The bovine abortion surveillance system in France aims to detect as early as possible any resurgence of bovine brucellosis, a disease of which the country has been declared free since 2005. It relies on the mandatory notification and testing of each aborting cow, but under-reporting is high. This research uses a new and simple approach which considers the calving interval (CI) as a "diagnostic test" to determine optimal cut-off point c and estimate diagnostic performance of the CI to identify aborting cows, and herds with multiple abortions (i.e. three or more aborting cows per calving season). The period between two artificial inseminations (AI) was considered as a "gold standard". During the 2006-2010 calving seasons, the mean optimal CI cut-off point for identifying aborting cows was 691 days for dairy cows and 703 days for beef cows. Depending on the calving season, production type and scale at which c was computed (individual or herd), the average sensitivity of the CI varied from 42.6% to 64.4%; its average specificity from 96.7% to 99.7%; its average positive predictive value from 27.6% to 65.4%; and its average negative predictive value from 98.7% to 99.8%. When applied to the French bovine population as a whole, this indicator identified 2-3% of cows suspected to have aborted, and 10-15% of herds suspected of multiple abortions. The optimal cut-off point and CI performance were consistent over calving seasons. By applying an optimal CI cut-off point to the cattle demographics database, it becomes possible to identify herds with multiple abortions, carry out retrospective investigations to find the cause of these abortions and monitor a posteriori compliance of farmers with their obligation to report abortions for brucellosis surveillance needs. Therefore, the CI could be used as an indicator of abortions to help improve the current mandatory notification surveillance system. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Determining the cut-off point of osteoporosis based on the osteoporosis self-assessment tool, body mass index and weight in Taiwanese young adult women.

    PubMed

    Chang, Shu Fang; Yang, Rong Sen

    2014-09-01

    To examine the cut-off point of the osteoporosis self-assessment tool, age, weight and body mass index for osteoporosis among young adult Taiwanese women, using a large-scale health examination database containing bone mineral density tests. The cut-off points of osteoporosis risk factors identified earlier focus on menopausal or senior Caucasian and Asian women. However, young adult Asian women have seldom been identified. A retrospective historical cohort study. Using the 2009-2011 health examination database of a large-scale medical centre in northern Taiwan, this study investigated young adult Asian women (i.e. range in age from 30-49 years) in Taiwan who had received dual-energy X-ray absorptiometry test. This study also explored the cut-off point, sensitivity, specificity and diagnostic accuracy of receiver operating characteristics of osteoporosis among young adult females in Taiwan. This study collected 2454 young adult Asian women in Taiwan. Cochran-Armitage analysis results indicated that the prevalence of osteoporosis increased with decreasing weight, body mass index and osteoporosis self-assessment method quartiles. According to the results of receiver operating characteristics, weight, body mass index and osteoporosis self-assessment tool approaches can generally be used as indicators to predict osteoporosis among young adult Asian women. Results of this study demonstrate that Taiwanese women contracting osteoporosis tend to be young and underweight, as well as having a low body mass index and osteoporosis self-assessment scores. Those results further suggest that the assessment indicators for cut-off points are appropriately suitable for young adult women in Taiwan. Early detection is the only available means of preventing osteoporosis. Professional nurses should apply convenient and accurate assessment procedures to help young adult women to adopt preventive strategies against osteoporosis early, thus eliminating the probability of osteoporotic fracture. © 2013 John Wiley & Sons Ltd.

  20. To what extent does the anxiety scale of the Four-Dimensional Symptom Questionnaire (4DSQ) detect specific types of anxiety disorder in primary care? A psychometric study

    PubMed Central

    2014-01-01

    Background Anxiety scales may help primary care physicians to detect specific anxiety disorders among the many emotionally distressed patients presenting in primary care. The anxiety scale of the Four-Dimensional Symptom Questionnaire (4DSQ) consists of an admixture of symptoms of specific anxiety disorders. The research questions were: (1) Is the anxiety scale unidimensional or multidimensional? (2) To what extent does the anxiety scale detect specific DSM-IV anxiety disorders? (3) Which cut-off points are suitable to rule out or to rule in (which) anxiety disorders? Methods We analyzed 5 primary care datasets with standardized psychiatric diagnoses and 4DSQ scores. Unidimensionality was assessed through confirmatory factor analysis (CFA). We examined mean scores and anxiety score distributions per disorder. Receiver operating characteristic (ROC) analysis was used to determine optimal cut-off points. Results Total n was 969. CFA supported unidimensionality. The anxiety scale performed slightly better in detecting patients with panic disorder, agoraphobia, social phobia, obsessive compulsive disorder (OCD) and post traumatic stress disorder (PTSD) than patients with generalized anxiety disorder (GAD) and specific phobia. ROC-analysis suggested that ≥4 was the optimal cut-off point to rule out and ≥10 the cut-off point to rule in anxiety disorders. Conclusions The 4DSQ anxiety scale measures a common trait of pathological anxiety that is characteristic of anxiety disorders, in particular panic disorder, agoraphobia, social phobia, OCD and PTSD. The anxiety score detects the latter anxiety disorders to a slightly greater extent than GAD and specific phobia, without being able to distinguish between the different anxiety disorder types. The cut-off points ≥4 and ≥10 can be used to separate distressed patients in three groups with a relatively low, moderate and high probability of having one or more anxiety disorders. PMID:24761829

  1. Accelerometer telemetry system

    NASA Technical Reports Server (NTRS)

    Konigsberg, E. (Inventor)

    1976-01-01

    An accelerometer telemetry system incorporated in a finger ring is used for monitoring the motor responses of a subject. The system includes an accelerometer, battery, and transmitter and provides information to a remote receiver regarding hand movements of a subject wearing the ring, without the constraints of wires. Possible applications include the detection of fatigue from the hand movements of the wearer.

  2. Linear Acceleration Measurement Utilizing Inter-Instrument Synchronization: A Comparison between Accelerometers and Motion-Based Tracking Approaches

    ERIC Educational Resources Information Center

    Callaway, Andrew J.; Cobb, Jon E.

    2012-01-01

    Where as video cameras are a reliable and established technology for the measurement of kinematic parameters, accelerometers are increasingly being employed for this type of measurement due to their ease of use, performance, and comparatively low cost. However, the majority of accelerometer-based studies involve a single channel due to the…

  3. Assessing Physical Activity in Children with Asthma: Convergent Validity between Accelerometer and Electronic Diary Data

    ERIC Educational Resources Information Center

    Floro, Josh N.; Dunton, Genevieve F.; Delfino, Ralph J.

    2009-01-01

    Convergent validity of accelerometer and electronic diary physical activity data was assessed in children with asthma. Sixty-two participants, ages 9-18 years, wore an accelerometer and reported their physical activity level in quarter-hour segments every 2 hr using the Ambulatory Diary Assessment (ADA). Moderate validity was found between…

  4. Turbulence detection using radiosondes: plugging the gaps in the observation of turbulence

    NASA Astrophysics Data System (ADS)

    Marlton, Graeme; Harrison, Giles; Williams, Paul; Nicoll, Keri

    2014-05-01

    Turbulence costs the airline industry tens of millions of dollars each year, through damage to aircraft and injury to passengers. Clear-air turbulence (CAT) is particularly problematic, as it cannot be detected using remote sensing methods and we lack consistent observations to validate forecast models. Here we describe two specially adapted meteorological radiosondes that are used to measure turbulence. The first sensor consists of a Hall-effect magnetometer, which uses the Earth's magnetic field as a reference point, allowing the motion of the sonde to be measured. The second consists of an accelerometer that measures the accelerations the balloon encounters. A solar radiation sensor is mounted at the top of the package, to determine whether the sonde is in cloud. Results from multiple flights over Reading, UK in different conditions, show both sensors detecting turbulent regions near jet boundaries and above cloud tops, with the accelerometer recording values in excess of 6g in these regions. Case studies will show how these observations can be used to test the performance of a selection of empirical turbulence diagnostics initialised from ERA-interim data.

  5. Honeybee Colony Vibrational Measurements to Highlight the Brood Cycle

    PubMed Central

    Bencsik, Martin; Le Conte, Yves; Reyes, Maritza; Pioz, Maryline; Whittaker, David; Crauser, Didier; Simon Delso, Noa; Newton, Michael I.

    2015-01-01

    Insect pollination is of great importance to crop production worldwide and honey bees are amongst its chief facilitators. Because of the decline of managed colonies, the use of sensor technology is growing in popularity and it is of interest to develop new methods which can more accurately and less invasively assess honey bee colony status. Our approach is to use accelerometers to measure vibrations in order to provide information on colony activity and development. The accelerometers provide amplitude and frequency information which is recorded every three minutes and analysed for night time only. Vibrational data were validated by comparison to visual inspection data, particularly the brood development. We show a strong correlation between vibrational amplitude data and the brood cycle in the vicinity of the sensor. We have further explored the minimum data that is required, when frequency information is also included, to accurately predict the current point in the brood cycle. Such a technique should enable beekeepers to reduce the frequency with which visual inspections are required, reducing the stress this places on the colony and saving the beekeeper time. PMID:26580393

  6. Urban MEMS based seismic network for post-earthquakes rapid disaster assessment

    NASA Astrophysics Data System (ADS)

    D'Alessandro, A.; Luzio, D.; D'Anna, G.

    2014-09-01

    In this paper, we introduce a project for the realization of the first European real-time urban seismic network based on Micro Electro-Mechanical Systems (MEMS) technology. MEMS accelerometers are a highly enabling technology, and nowadays, the sensitivity and the dynamic range of these sensors are such as to allow the recording of earthquakes of moderate magnitude even at a distance of several tens of kilometers. Moreover, thanks to their low cost and smaller size, MEMS accelerometers can be easily installed in urban areas in order to achieve an urban seismic network constituted by high density of observation points. The network is being implemented in the Acireale Municipality (Sicily, Italy), an area among those with the highest hazard, vulnerability and exposure to the earthquake of the Italian territory. The main objective of the implemented urban network will be to achieve an effective system for post-earthquake rapid disaster assessment. The earthquake recorded, also that with moderate magnitude will be used for the effective seismic microzonation of the area covered by the network. The implemented system will be also used to realize a site-specific earthquakes early warning system.

  7. Effectiveness of the IDEFICS intervention on objectively measured physical activity and sedentary time in European children.

    PubMed

    Verbestel, V; De Henauw, S; Barba, G; Eiben, G; Gallois, K; Hadjigeorgiou, C; Konstabel, K; Maes, L; Mårild, S; Molnár, D; Moreno, L A; Oja, L; Pitsiladis, Y; Ahrens, W; Pigeot, I; De Bourdeaudhuij, I

    2015-12-01

    This paper reports on the effectiveness of the prevention of dietary- and lifestyle-induced health effects in children and infants (IDEFICS) intervention on objectively measured physical activity (PA) and sedentary time (ST) in 2- to 9.9-year-old European boys and girls. The intervention was evaluated after 2 years through a non-randomized cluster-controlled trial in eight European countries (one control and one intervention community per country). All children in the intervention group received a culturally adapted childhood obesity prevention programme through the community, schools/kindergartens and family. A random sub-sample of children participating in the IDEFICS study wore an accelerometer at baseline and follow-up for at least 3 days (n = 9,184). Of this sample, 81% provided valid accelerometer data at baseline (n = 7,413; 51% boys; 6.21 ± 1.76 years; boys: 617 ± 170 cpm day(-1) ; girls 556 ± 156 cpm day(-1) ) and 3,010 children provided valid accelerometer data at baseline and during the follow-up survey 2 years later. In boys and girls, no significant differences in PA and ST were found between intervention and control groups over 2 years. Strong temporal effects were found in the total sample of boys and girls: the percentage of time spent in light PA per day decreased by 4 percentage points in both boys and girls between baseline and follow-up (both: p < 0.001), while time spent in ST per day increased by 4 percentage points in both sexes over time (both: p < 0.001). Percentage of time spent in moderate-to-vigorous PA per day remained stable over time in boys and girls. Despite the socio-ecological approach and implementation of a culturally adapted intervention in each country, no effects of the IDEFICS intervention were found on children's objectively measured PA and ST. Behavioural interventions for children may need to enhance specificity and intensity at the family level using other behaviour change techniques and more direct strategies to reach parents. © 2015 World Obesity.

  8. Self Diagnostic Accelerometer Ground Testing on a C-17 Aircraft Engine

    NASA Technical Reports Server (NTRS)

    Tokars, Roger P.; Lekki, John D.

    2013-01-01

    The self diagnostic accelerometer (SDA) developed by the NASA Glenn Research Center was tested for the first time in an aircraft engine environment as part of the Vehicle Integrated Propulsion Research (VIPR) program. The VIPR program includes testing multiple critical flight sensor technologies. One such sensor, the accelerometer, measures vibrations to detect faults in the engine. In order to rely upon the accelerometer, the health of the accelerometer must be ensured. Sensor system malfunction is a significant contributor to propulsion in flight shutdowns (IFSD) which can lead to aircraft accidents when the issue is compounded with an inappropriate crew response. The development of the SDA is important for both reducing the IFSD rate, and hence reducing the rate at which this component failure type can put an aircraft in jeopardy, and also as a critical enabling technology for future automated malfunction diagnostic systems. The SDA is a sensor system designed to actively determine the accelerometer structural health and attachment condition, in addition to making vibration measurements. The SDA uses a signal conditioning unit that sends an electrical chirp to the accelerometer and recognizes changes in the response due to changes in the accelerometer health and attachment condition. In an effort toward demonstrating the SDAs flight worthiness and robustness, multiple SDAs were mounted and tested on a C-17 aircraft engine. The engine test conditions varied from engine off, to idle, to maximum power. The two SDA attachment conditions used were fully tight and loose. The newly developed SDA health algorithm described herein uses cross correlation pattern recognition to discriminate a healthy from a faulty SDA. The VIPR test results demonstrate for the first time the robustness of the SDA in an engine environment characterized by high vibration levels.

  9. Combining global positioning system and accelerometer data to determine the locations of physical activity in children.

    PubMed

    Oreskovic, Nicolas M; Blossom, Jeff; Field, Alison E; Chiang, Sylvia R; Winickoff, Jonathan P; Kleinman, Ronald E

    2012-05-01

    National trends indicate that children and adolescents are not achieving sufficient levels of physical activity. Combining global positioning system (GPS) technology with accelerometers has the potential to provide an objective determination in locations where youth engage in physical activity. The aim of this study was to identify the optimal methods for collecting combined accelerometer and GPS data in youth, to best locate where children spend time and are physically active. A convenience sample of 24 mid-school children in Massachusetts was included. Accelerometers and GPS units were used to quantify and locate childhood physical activity over 5 weekdays and 2 weekend days. Accelerometer and GPS data were joined by time and mapped with a geographical information system (GIS) using ArcGIS software. Data were collected in winter, spring, summer in 2009-2010, collecting a total of 26,406 matched datapoints overall. Matched data yield was low (19.1% total), regardless of season (winter, 12.8%; spring, 30.1%; summer, 14.3%). Teacher-provided, pre-charged equipment yielded the most matched (30.1%; range: 10.1-52.3%) and greatest average days (6.1 days) of data. Across all seasons, children spent most of their time at home. Outdoor use patterns appeared to vary by season, with street use increasing in spring, and park and playground use increasing in summer. Children spent equal amounts of physical activity time at home and walking in the streets. Overall, the various methods for combining GPS and accelerometer data provided similarly low amounts of combined data. No combined GPS and accelerometer data collection method proved superior in every data return category, but use of GIS to map joined accelerometer and GPS data can demarcate childhood physical activity locations.

  10. Self diagnostic accelerometer ground testing on a C-17 aircraft engine

    NASA Astrophysics Data System (ADS)

    Tokars, Roger P.; Lekki, John D.

    The self diagnostic accelerometer (SDA) developed by the NASA Glenn Research Center was tested for the first time in an aircraft engine environment as part of the Vehicle Integrated Propulsion Research (VIPR) program. The VIPR program includes testing multiple critical flight sensor technologies. One such sensor, the accelerometer, measures vibrations to detect faults in the engine. In order to rely upon the accelerometer, the health of the accelerometer must be ensured. Sensor system malfunction is a significant contributor to propulsion in flight shutdowns (IFSD) which can lead to aircraft accidents when the issue is compounded with an inappropriate crew response. The development of the SDA is important for both reducing the IFSD rate, and hence reducing the rate at which this component failure type can put an aircraft in jeopardy, and also as a critical enabling technology for future automated malfunction diagnostic systems. The SDA is a sensor system designed to actively determine the accelerometer structural health and attachment condition, in addition to making vibration measurements. The SDA uses a signal conditioning unit that sends an electrical chirp to the accelerometer and recognizes changes in the response due to changes in the accelerometer health and attachment condition. In an effort toward demonstrating the SDA's flight worthiness and robustness, multiple SDAs were mounted and tested on a C-17 aircraft engine. The engine test conditions varied from engine off, to idle, to maximum power. The two SDA attachment conditions used were fully tight and loose. The newly developed SDA health algorithm described herein uses cross correlation pattern recognition to discriminate a healthy from a faulty SDA. The VIPR test results demonstrate for the first time the robustness of the SDA in an engine environment characterized by high vibration levels.

  11. Accelerometer use during field-based physical activity research in children and adolescents with intellectual disabilities: a systematic review.

    PubMed

    McGarty, Arlene M; Penpraze, Victoria; Melville, Craig A

    2014-05-01

    Many methodological questions and issues surround the use of accelerometers as a measure of physical activity during field-based research. To ensure overall research quality and the accuracy of results, methodological decisions should be based on study research questions. This paper aims to systematically review accelerometer use during field-based research in children and adolescents with intellectual disabilities. Medline, Embase, Cochrane Library, Web of Knowledge, PsycINFO, PubMed, and a thesis database (up to May 2013) were searched to identify relevant articles. Articles which used accelerometry-based monitors, quantified activity levels, and included ambulatory children and adolescents (≤ 18 years) with intellectual disabilities were included. Based on best practice guidelines, a form was developed to extract data based on 17 research components of accelerometer use. The search identified 429 articles. Ten full-text articles met the criteria and were included in the review. Many shortcomings in accelerometer use were identified, with the percentage of review criteria met ranging from 12% to 47%. Various methods of accelerometer use were reported, with most use decisions not based on population-specific research. However, a lack of measurement research, e.g., calibration/validation, for children and adolescents with intellectual disabilities is limiting the ability of field-based researchers to make to the most appropriate accelerometer use decisions. The methods of accelerometer use employed can have significant effects on the quality and validity of results produced, which researchers should be more aware of. To allow informed use decisions, there should be a greater focus on measurement research related to children and adolescents with intellectual disabilities. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Temperature insensitive all-fiber accelerometer using a photonic crystal fiber long-period grating interferometer

    NASA Astrophysics Data System (ADS)

    Zheng, Shijie; Zhu, Yinian; Krishnaswamy, Sridhar

    2012-04-01

    Fiber-optic accelerometers have attracted great attention in recent years due to the fact that they have many advantages over electrical counterparts because all-fiber accelerometers have the capabilities for multiplexing to reduce cabling and to transmit signals over a long distance. They are also immune to electromagnetic interference. We propose and develop a compact and robust photonic crystal fiber (PCF) Mach-Zehnder interferometer (MZI) that can be implemented as an accelerometer for measurements of vibration and displacement. To excite core mode to couple out with cladding modes, two long-period gratings (LPGs) with identical transmission spectra are needed to be written in an endless single-mode PCF using a CO2 laser. The first LPG can couple a part of core mode to several cladding modes. After the light beams travel at different speeds over a certain length of the core and cladding, the cladding modes will be recoupled back to the core when they meet the second LPG, resulting in interference between the core mode and cladding modes. Dynamic strain is introduced to the PCF-MZI fiber segment that is bonded onto a spring-mass system. The shift of interference fringe can be measured by a photodetector, and the transformed analog voltage signal is proportional to the acceleration of the sensor head. Based on simulations of the PCF-MZI accelerometer, we can get a sensitivity of ~ 0.08 nm/g which is comparable with fiber Bragg grating (FBG) accelerometers. The proposed accelerometer has a capability of temperature insensitivity; therefore, no thermal-compensation scheme is required. Experimental results indicate that the PCF-MZI accelerometer may be a good candidate sensor for applications in civil engineering infrastructure and aeronautical platforms.

  13. Validation of accelerometer wear and nonwear time classification algorithm.

    PubMed

    Choi, Leena; Liu, Zhouwen; Matthews, Charles E; Buchowski, Maciej S

    2011-02-01

    the use of movement monitors (accelerometers) for measuring physical activity (PA) in intervention and population-based studies is becoming a standard methodology for the objective measurement of sedentary and active behaviors and for the validation of subjective PA self-reports. A vital step in PA measurement is the classification of daily time into accelerometer wear and nonwear intervals using its recordings (counts) and an accelerometer-specific algorithm. the purpose of this study was to validate and improve a commonly used algorithm for classifying accelerometer wear and nonwear time intervals using objective movement data obtained in the whole-room indirect calorimeter. we conducted a validation study of a wear or nonwear automatic algorithm using data obtained from 49 adults and 76 youth wearing accelerometers during a strictly monitored 24-h stay in a room calorimeter. The accelerometer wear and nonwear time classified by the algorithm was compared with actual wearing time. Potential improvements to the algorithm were examined using the minimum classification error as an optimization target. the recommended elements in the new algorithm are as follows: 1) zero-count threshold during a nonwear time interval, 2) 90-min time window for consecutive zero or nonzero counts, and 3) allowance of 2-min interval of nonzero counts with the upstream or downstream 30-min consecutive zero-count window for detection of artifactual movements. Compared with the true wearing status, improvements to the algorithm decreased nonwear time misclassification during the waking and the 24-h periods (all P values < 0.001). the accelerometer wear or nonwear time algorithm improvements may lead to more accurate estimation of time spent in sedentary and active behaviors.

  14. Reliability and Validity of Objective Measures of Physical Activity in Youth With Cerebral Palsy Who Are Ambulatory.

    PubMed

    O'Neil, Margaret E; Fragala-Pinkham, Maria; Lennon, Nancy; George, Ameeka; Forman, Jeffrey; Trost, Stewart G

    2016-01-01

    Physical therapy for youth with cerebral palsy (CP) who are ambulatory includes interventions to increase functional mobility and participation in physical activity (PA). Thus, reliable and valid measures are needed to document PA in youth with CP. The purpose of this study was to evaluate the inter-instrument reliability and concurrent validity of 3 accelerometer-based motion sensors with indirect calorimetry as the criterion for measuring PA intensity in youth with CP. Fifty-seven youth with CP (mean age=12.5 years, SD=3.3; 51% female; 49.1% with spastic hemiplegia) participated. Inclusion criteria were: aged 6 to 20 years, ambulatory, Gross Motor Function Classification System (GMFCS) levels I through III, able to follow directions, and able to complete the full PA protocol. Protocol activities included standardized activity trials with increasing PA intensity (resting, writing, household chores, active video games, and walking at 3 self-selected speeds), as measured by weight-relative oxygen uptake (in mL/kg/min). During each trial, participants wore bilateral accelerometers on the upper arms, waist/hip, and ankle and a portable indirect calorimeter. Intraclass coefficient correlations (ICCs) were calculated to evaluate inter-instrument reliability (left-to-right accelerometer placement). Spearman correlations were used to examine concurrent validity between accelerometer output (activity and step counts) and indirect calorimetry. Friedman analyses of variance with post hoc pair-wise analyses were conducted to examine the validity of accelerometers to discriminate PA intensity across activity trials. All accelerometers exhibited excellent inter-instrument reliability (ICC=.94-.99) and good concurrent validity (rho=.70-.85). All accelerometers discriminated PA intensity across most activity trials. This PA protocol consisted of controlled activity trials. Accelerometers provide valid and reliable measures of PA intensity among youth with CP. © 2016 American Physical Therapy Association.

  15. Multi-cut solutions in Chern-Simons matrix models

    NASA Astrophysics Data System (ADS)

    Morita, Takeshi; Sugiyama, Kento

    2018-04-01

    We elaborate the Chern-Simons (CS) matrix models at large N. The saddle point equations of these matrix models have a curious structure which cannot be seen in the ordinary one matrix models. Thanks to this structure, an infinite number of multi-cut solutions exist in the CS matrix models. Particularly we exactly derive the two-cut solutions at finite 't Hooft coupling in the pure CS matrix model. In the ABJM matrix model, we argue that some of multi-cut solutions might be interpreted as a condensation of the D2-brane instantons.

  16. Cutting assembly

    DOEpatents

    Racki, Daniel J.; Swenson, Clark E.; Bencloski, William A.; Wineman, Arthur L.

    1984-01-01

    A cutting apparatus includes a support table mounted for movement toward and away from a workpiece and carrying a mirror which directs a cutting laser beam onto the workpiece. A carrier is rotatably and pivotally mounted on the support table between the mirror and workpiece and supports a conduit discharging gas toward the point of impingement of the laser beam on the workpiece. Means are provided for rotating the carrier relative to the support table to place the gas discharging conduit in the proper positions for cuts made in different directions on the workpiece.

  17. Bulk Micromachined 6H-SiC High-g Piezoresistive Accelerometer Fabricated and Tested

    NASA Technical Reports Server (NTRS)

    Okojie, Robert S.

    2002-01-01

    High-g accelerometers are needed in certain applications, such as in the study and analysis of high-g impact landings and projectiles. Also, these accelerometers must survive the high electromagnetic fields associated with the all-electric vehicle technology needed for aerospace applications. The choice of SiC is largely due to its excellent thermomechanical properties over conventional silicon-based accelerometers, whose material properties inhibit applicability in high electromagnetic radiation and high temperatures (>150 C) unless more complex and sometimes costly packaging schemes are adopted. This work was the outcome of a NASA Glenn Research Center summer internship program, in collaboration with Cornell University and the Munitions Directorate of the U.S. Air Force in Eglin, Florida. It aimed to provide the enabling technology infrastructure (modeling, fabrication, and validation) for the implementation of SiC accelerometers designed specifically for harsh environments.

  18. System for estimating fatigue damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LeMonds, Jeffrey; Guzzo, Judith Ann; Liu, Shaopeng

    In one aspect, a system for estimating fatigue damage in a riser string is provided. The system includes a plurality of accelerometers which can be deployed along a riser string and a communications link to transmit accelerometer data from the plurality of accelerometers to one or more data processors in real time. With data from a limited number of accelerometers located at sensor locations, the system estimates an optimized current profile along the entire length of the riser including riser locations where no accelerometer is present. The optimized current profile is then used to estimate damage rates to individual risermore » components and to update a total accumulated damage to individual riser components. The number of sensor locations is small relative to the length of a deepwater riser string, and a riser string several miles long can be reliably monitored along its entire length by fewer than twenty sensor locations.« less

  19. Principle research on a single mass piezoelectric six-degrees-of-freedom accelerometer.

    PubMed

    Liu, Jun; Li, Min; Qin, Lan; Liu, Jingcheng

    2013-08-16

    A signal mass piezoelectric six-degrees-of-freedom (six-DOF) accelerometer is put forward in response to the need for health monitoring of the dynamic vibration characteristics of high grade digitally controlled machine tools. The operating principle of the piezoelectric six-degrees-of-freedom accelerometer is analyzed, and its structure model is constructed. The numerical simulation model (finite element model) of the six axis accelerometer is established. Piezoelectric quartz is chosen for the acceleration sensing element and conversion element, and its static sensitivity, static coupling interference and dynamic natural frequency, dynamic cross coupling are analyzed by ANSYS software. Research results show that the piezoelectric six-DOF accelerometer has advantages of simple and rational structure, correct sensing principle and mathematic model, good linearity, high rigidity, and theoretical natural frequency is more than 25 kHz, no nonlinear cross coupling and no complex decoupling work.

  20. Principle Research on a Single Mass Piezoelectric Six-Degrees-of-Freedom Accelerometer

    PubMed Central

    Liu, Jun; Li, Min; Qin, Lan; Liu, Jingcheng

    2013-01-01

    A signal mass piezoelectric six-degrees-of-freedom (six-DOF) accelerometer is put forward in response to the need for health monitoring of the dynamic vibration characteristics of high grade digitally controlled machine tools. The operating principle of the piezoelectric six-degrees-of-freedom accelerometer is analyzed, and its structure model is constructed. The numerical simulation model (finite element model) of the six axis accelerometer is established. Piezoelectric quartz is chosen for the acceleration sensing element and conversion element, and its static sensitivity, static coupling interference and dynamic natural frequency, dynamic cross coupling are analyzed by ANSYS software. Research results show that the piezoelectric six-DOF accelerometer has advantages of simple and rational structure, correct sensing principle and mathematic model, good linearity, high rigidity, and theoretical natural frequency is more than 25 kHz, no nonlinear cross coupling and no complex decoupling work. PMID:23959243

  1. Diamond turning of Si and Ge single crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blake, P.; Scattergood, R.O.

    Single-point diamond turning studies have been completed on Si and Ge crystals. A new process model was developed for diamond turning which is based on a critical depth of cut for plastic flow-to-brittle fracture transitions. This concept, when combined with the actual machining geometry for single-point turning, predicts that {open_quotes}ductile{close_quotes} machining is a combined action of plasticity and fracture. Interrupted cutting experiments also provide a meant to directly measure the critical depth parameter for given machining conditions.

  2. Shaping of Rack Cutter Original Profile for Fine-module Ratchet Teeth Cutting

    NASA Astrophysics Data System (ADS)

    Sharkov, O. V.; Koryagin, S. I.; Velikanov, N. L.

    2018-05-01

    The design models and the process of shaping the cutting edges of the rack cutter for cutting fine-module ratchet teeth are considered in the article. The use of fine-module ratchet teeth can reduce the noise and impact loads during operation of the freewheel mechanisms. Mathematical dependencies for calculating the coordinates determining the geometric position of the points of the front and back edges of the cutting profile of the rack cutter, the workpiece angle of rotation during cutting the ratchet teeth were obtained. When applying the developed method, the initial data are: the radii of the workpiece circumferences passing through the dedendum of the external and internal cut teeth; gradient angles of the front and back edges of the rail.

  3. Lower limb muscle strength is associated with poor balance in middle-aged women: linear and nonlinear analyses.

    PubMed

    Wu, F; Callisaya, M; Laslett, L L; Wills, K; Zhou, Y; Jones, G; Winzenberg, T

    2016-07-01

    This was the first study investigating both linear associations between lower limb muscle strength and balance in middle-aged women and the potential for thresholds for the associations. There was strong evidence that even in middle-aged women, poorer LMS was associated with reduced balance. However, no evidence was found for thresholds. Decline in balance begins in middle age, yet, the role of muscle strength in balance is rarely examined in this age group. We aimed to determine the association between lower limb muscle strength (LMS) and balance in middle-aged women and investigate whether cut-points of LMS exist that might identify women at risk of poorer balance. Cross-sectional analysis of 345 women aged 36-57 years was done. Associations between LMS and balance tests (timed up and go (TUG), step test (ST), functional reach test (FRT), and lateral reach test (LRT)) were assessed using linear regression. Nonlinear associations were explored using locally weighted regression smoothing (LOWESS) and potential cut-points identified using nonlinear least-squares estimation. Segmented regression was used to estimate associations above and below the identified cut-points. Weaker LMS was associated with poorer performance on the TUG (β -0.008 (95 % CI: -0.010, -0.005) second/kg), ST (β 0.031 (0.011, 0.051) step/kg), FRT (β 0.071 (0.047, 0.096) cm/kg), and LRT (β 0.028 (0.011, 0.044) cm/kg), independent of confounders. Potential nonlinear associations were evident from LOWESS results; significant cut-points of LMS were identified for all balance tests (29-50 kg). However, excepting ST, cut-points did not persist after excluding potentially influential data points. In middle-aged women, poorer LMS is associated with reduced balance. Therefore, improving muscle strength in middle-age may be a useful strategy to improve balance and reduce falls risk in later life. Middle-aged women with low muscle strength may be an effective target group for future randomized controlled trials. Australian New Zealand Clinical Trials Registry (ANZCTR) NCT00273260.

  4. Calculus, Paper, Scissors

    ERIC Educational Resources Information Center

    Flores, Luis; Flores, Alfinio

    2006-01-01

    The idea of cutting out a curve while looking at the direction of cut of the scissors is used to explore concepts related to curves, tangents and derivatives, especially tangent line, concavity and points of inflection, curvature, and a curve as envelope of tangent lines. (Contains 6 figures.)

  5. Silicon microengineering for accelerometers

    NASA Astrophysics Data System (ADS)

    Satchell, D. W.

    Silicon microengineering enables the excellent mechanical properties of silicon to be combined with electronic ones to produce accelerometers of good performance, small size and low cost. The design and fabrication of two types of analogue accelerometer, using this technique, are described. One employs implanted strain gauges to give a dc output, while the other has a strain-sensitive resonant structure which gives a varying frequency signal.

  6. Mother-reported sleep, accelerometer-estimated sleep and weight status in Mexican American children: sleep duration is associated with increased adiposity and risk for overweight/obese status

    USDA-ARS?s Scientific Manuscript database

    We know of no studies comparing parent-reported sleep with accelerometer-estimated sleep in their relation to paediatric adiposity. We examined: (i) the reliability of mother-reported sleep compared with accelerometer-estimated sleep; and (ii) the relationship between both sleep measures and child a...

  7. Actogram analysis of free-flying migratory birds: new perspectives based on acceleration logging.

    PubMed

    Bäckman, Johan; Andersson, Arne; Pedersen, Lykke; Sjöberg, Sissel; Tøttrup, Anders P; Alerstam, Thomas

    2017-07-01

    The use of accelerometers has become an important part of biologging techniques for large-sized birds with accelerometer data providing information about flight mode, wing-beat pattern, behaviour and energy expenditure. Such data show that birds using much energy-saving soaring/gliding flight like frigatebirds and swifts can stay airborne without landing for several months. Successful accelerometer studies have recently been conducted also for free-flying small songbirds during their entire annual cycle. Here we review the principles and possibilities for accelerometer studies in bird migration. We use the first annual actograms (for red-backed shrike Lanius collurio) to explore new analyses and insights that become possible with accelerometer data. Actogram data allow precise estimates of numbers of flights, flight durations as well as departure/landing times during the annual cycle. Annual and diurnal rhythms of migratory flights, as well as prolonged nocturnal flights across desert barriers are illustrated. The shifting balance between flight, rest and different intensities of activity throughout the year as revealed by actogram data can be used to analyse exertion levels during different phases of the life cycle. Accelerometer recording of the annual activity patterns of individual birds will open up a new dimension in bird migration research.

  8. densityCut: an efficient and versatile topological approach for automatic clustering of biological data

    PubMed Central

    Ding, Jiarui; Shah, Sohrab; Condon, Anne

    2016-01-01

    Motivation: Many biological data processing problems can be formalized as clustering problems to partition data points into sensible and biologically interpretable groups. Results: This article introduces densityCut, a novel density-based clustering algorithm, which is both time- and space-efficient and proceeds as follows: densityCut first roughly estimates the densities of data points from a K-nearest neighbour graph and then refines the densities via a random walk. A cluster consists of points falling into the basin of attraction of an estimated mode of the underlining density function. A post-processing step merges clusters and generates a hierarchical cluster tree. The number of clusters is selected from the most stable clustering in the hierarchical cluster tree. Experimental results on ten synthetic benchmark datasets and two microarray gene expression datasets demonstrate that densityCut performs better than state-of-the-art algorithms for clustering biological datasets. For applications, we focus on the recent cancer mutation clustering and single cell data analyses, namely to cluster variant allele frequencies of somatic mutations to reveal clonal architectures of individual tumours, to cluster single-cell gene expression data to uncover cell population compositions, and to cluster single-cell mass cytometry data to detect communities of cells of the same functional states or types. densityCut performs better than competing algorithms and is scalable to large datasets. Availability and Implementation: Data and the densityCut R package is available from https://bitbucket.org/jerry00/densitycut_dev. Contact: condon@cs.ubc.ca or sshah@bccrc.ca or jiaruid@cs.ubc.ca Supplementary information: Supplementary data are available at Bioinformatics online. PMID:27153661

  9. Dynamic Loads Generation for Multi-Point Vibration Excitation Problems

    NASA Technical Reports Server (NTRS)

    Shen, Lawrence

    2011-01-01

    A random-force method has been developed to predict dynamic loads produced by rocket-engine random vibrations for new rocket-engine designs. The method develops random forces at multiple excitation points based on random vibration environments scaled from accelerometer data obtained during hot-fire tests of existing rocket engines. This random-force method applies random forces to the model and creates expected dynamic response in a manner that simulates the way the operating engine applies self-generated random vibration forces (random pressure acting on an area) with the resulting responses that we measure with accelerometers. This innovation includes the methodology (implementation sequence), the computer code, two methods to generate the random-force vibration spectra, and two methods to reduce some of the inherent conservatism in the dynamic loads. This methodology would be implemented to generate the random-force spectra at excitation nodes without requiring the use of artificial boundary conditions in a finite element model. More accurate random dynamic loads than those predicted by current industry methods can then be generated using the random force spectra. The scaling method used to develop the initial power spectral density (PSD) environments for deriving the random forces for the rocket engine case is based on the Barrett Criteria developed at Marshall Space Flight Center in 1963. This invention approach can be applied in the aerospace, automotive, and other industries to obtain reliable dynamic loads and responses from a finite element model for any structure subject to multipoint random vibration excitations.

  10. Tightly-coupled real-time analysis of GPS and accelerometer data for translational and rotational ground motions and application to earthquake and tsunami early warning

    NASA Astrophysics Data System (ADS)

    Geng, J.; Bock, Y.; Melgar, D.; Hasse, J.; Crowell, B. W.

    2013-12-01

    High-rate GPS can play an important role in earthquake early warning (EEW) systems for large (>M6) events by providing permanent displacements immediately as they are achieved, to be used in source inversions that can be repeatedly updated as more information becomes available. This is most valuable to implement at a site very near the potential source rupture, where broadband seismometers are likely to clip, and accelerometer data cannot be objectively integrated to produce reliable displacements in real time. At present, more than 525 real-time GPS stations have been established in western North America, which are being integrated into EEW systems. Our analysis technique relies on a tightly-coupled combination of GPS and accelerometer data, an extension of precise point positioning with ambiguity resolution (PPP-AR). We operate a PPP service based on North American stations available through the IGS and UNAVCO/PBO. The service provides real-time satellite clock and fractional-cycle bias products that allow us to position individual client stations in the zone of deformation. The service reference stations are chosen to be further than 200 km from the primary zones of tectonic deformation in the western U.S. to avoid contamination of the satellite products during a large seismic event. At client stations, accelerometer data are applied as tight constraints on the positions between epochs in PPP-AR, which improves cycle-slip repair and rapid ambiguity resolution after GPS outages. Furthermore, we estimate site displacements, seismic velocities, and coseismic ground tilts to facilitate the analysis of ground motion characteristics and the inversion for source mechanisms. The seismogeodetic displacement and velocity waveforms preserves the detection of P wave arrivals, and provides P-wave arrival displacement that is key new information for EEW. Our innovative solution method for coseismic tilts mitigates an error source that has continually plagued strong motion data analysis, and has a resolution of about 0.01 degrees. At present, there are few collocations of GPS and accelerometers in western North America (the exception being the BARD network in northern California) so we have developed a cost-effective way to upgrade existing real-time GPS stations with low-cost MEMS accelerometers; fifteen PBO and SCIGN stations in southern California have already been upgraded. We demonstrate our method of recovering broadband displacement and tilt waveforms using 13 experiments from the single-axis George E. Brown Jr. Network for Earthquake Engineering Simulation Large High-Performance Outdoor Shake Table at the University of California San Diego. Then we apply the method to data from the 2010 Mw 7.2 El Mayor-Cucapah earthquake and the 2011 Mw 9.0 Tohoku-oki earthquake to illustrate the improvement over standard base-line correction acceleration techniques and to demonstrate the order of magnitude of tilt errors present in typical observations.

  11. Time Periods of Unusual Density Behavior Observed by GRACE and CHAMP

    NASA Astrophysics Data System (ADS)

    McLaughlin, C. A.; Fattig, E.; Mysore Krishna, D.; Locke, T.; Mehta, P. M.

    2011-12-01

    Time periods of low cross correlation between precision orbit ephemeris (POE) derived density and accelerometer density for CHAMP and GRACE are examined. In particular, the cross correlation for GRACE dropped from typical values near 0.9 to much lower values and then returned to typical over the time period of late October to late December of 2005. This time period includes a maneuver where GRACE-A and GRACE-B swapped positions. However, the drop in cross correlation begins and reaches its low point before the maneuvers begin. In addition, the densities were found using GRACE-A, but GRACE-B did most of the maneuvering. The time period is characterized by high frequency variations in accelerometer density of the same magnitude as the daylight to eclipse variations over the course of an orbit. However, the daylight to eclipse variations are particularly small during this time period because the orbit plane is near the terminator. Additionally, the difference between the accelerometer and POE derived densities are not unusually large during this time period. This implies the variations are not unusual, just more significant when the orbit plane is near terminator. Cyclical variations in correlation of the POE derived densities with accelerometer derived densities are seen for both GRACE and CHAMP, but the magnitude of the variations are much larger for GRACE, possibly because of the higher altitude of GRACE. The cycles seem to be phased so that low correlations occur with low beta angle when the orbit plane is near the terminator. The low correlation is possibly caused by the lower amplitude of the daylight to eclipse signal making higher frequency variations relatively more important. However, another possible explanation is terminator waves in density that propagate to the thermosphere from lower in the atmosphere. These waves have been observed in CHAMP accelerometer data and global circulation model simulations. Further investigation is needed to see if the variations correspond to terminator waves or if they represent typical high frequency signal from another source that is more apparent when the orbit plane is near the terminator. 1. C. A. McLaughlin, E. Fattig, D. Mysore Krishna, and P. M. Mehta, "Time Periods of Anomalous Density for GRACE and CHAMP," AAS/AIAA Astrodynamics Specialists Conference, AAS 11-613, Girdwood, AK, August 2011. 2. C. A. McLaughlin, A. Hiatt, and T. Lechtenberg, "Calibrating Precision Orbit Derived Total Density," Journal of Spacecraft and Rockets, Vol. 48, No. 1, January-February 2011, pp. 166-174.

  12. The effectiveness of cut-proof glove liners: cut and puncture resistance, dexterity, and sensibility.

    PubMed

    Salkin, J A; Stuchin, S A; Kummer, F J; Reininger, R

    1995-11-01

    Five types of commercial glove liners (within double latex gloves) were compared to single and double latex gloves for cut and puncture resistance and for relative manual dexterity and degree of sensibility. An apparatus was constructed to test glove-pseudofinger constructs in either a cutting or puncture mode. Cutting forces, cutting speed, and type of blade (serrated or scalpel blade) were varied and the time to cut-through measured by an electrical conductivity circuit. Penetration forces were similarly determined with a scalpel blade and a suture needle using a spring scale loading apparatus. Dexterity was measured with an object placement task among a group of orthopedic surgeons. Sensibility was assessed with Semmes-Weinstein monofilaments, two-point discrimination, and vibrametry using standard techniques and rating scales. A subjective evaluation was performed at the end of testing. Time to cut-through for the liners ranged from 2 to 30 seconds for a rapid oscillating scalpel and 4 to 40 seconds for a rapid oscillating serrated knife under minimal loads. When a 1 kg load was added, times to cut-through ranged from 0.4 to 1.0 second. In most cases, the liners were superior to double latex. On average, 100% more force was required to penetrate the liners with a scalpel and 50% more force was required to penetrate the liners with a suture needle compared to double latex. Object placement task times were not significantly liners compared to double latex gloves. Semmes-Weinstein monofilaments, two-point discrimination, and vibrametry showed no difference in sensibility among the various liners and double latex gloves. Subjects felt that the liners were minimally to moderately impairing. An acclimation period may be required for their effective use.

  13. A description of disordered eating behaviors in Latino males.

    PubMed

    Reyes-Rodriguez, Mae Lynn; Sala, Margarita; Von Holle, Ann; Unikel, Claudia; Bulik, Cynthia M; Camara-Fuentes, Luis; Suarez-Torres, Alba

    2011-01-01

    To explore disordered eating and eating disorders (EDs) in Latino males. Participants are 722 male college students from a larger prevalence study conducted in the University of Puerto Rico system. Participants were selected from a list of sections of required courses for first-year students on each campus. Self-report instruments were used to explore ED symptoms (the Eating Attitudes Test [EAT-26] and the Bulimia Test-Revised [BULIT-26-R] and the Beck Depression Inventory depression (BDI). Overall, 2.26% scored above the cut-off point on the BULIT-R and 5.08% score above the cut-off point on the EAT-26. Of the males, 4.43% reported sufficient frequency and severity to approximate DSM-IV criteria for bulimia nervosa. Depression symptomatology was found in those who scored above the cut-off point on both instruments of EDs. College health practitioners should be aware of disordered eating in Latino males and include them in efforts to detect disordered eating behaviors in college students.

  14. Enhancing efficiency and quality of statistical estimation of immunogenicity assay cut points through standardization and automation.

    PubMed

    Su, Cheng; Zhou, Lei; Hu, Zheng; Weng, Winnie; Subramani, Jayanthi; Tadkod, Vineet; Hamilton, Kortney; Bautista, Ami; Wu, Yu; Chirmule, Narendra; Zhong, Zhandong Don

    2015-10-01

    Biotherapeutics can elicit immune responses, which can alter the exposure, safety, and efficacy of the therapeutics. A well-designed and robust bioanalytical method is critical for the detection and characterization of relevant anti-drug antibody (ADA) and the success of an immunogenicity study. As a fundamental criterion in immunogenicity testing, assay cut points need to be statistically established with a risk-based approach to reduce subjectivity. This manuscript describes the development of a validated, web-based, multi-tier customized assay statistical tool (CAST) for assessing cut points of ADA assays. The tool provides an intuitive web interface that allows users to import experimental data generated from a standardized experimental design, select the assay factors, run the standardized analysis algorithms, and generate tables, figures, and listings (TFL). It allows bioanalytical scientists to perform complex statistical analysis at a click of the button to produce reliable assay parameters in support of immunogenicity studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Classification and identification of reading and math disabilities: the special case of comorbidity.

    PubMed

    Branum-Martin, Lee; Fletcher, Jack M; Stuebing, Karla K

    2013-01-01

    Much of learning disabilities research relies on categorical classification frameworks that use psychometric tests and cut points to identify children with reading or math difficulties. However, there is increasing evidence that the attributes of reading and math learning disabilities are dimensional, representing correlated continua of severity. We discuss issues related to categorical and dimensional approaches to reading and math disabilities, and their comorbid associations, highlighting problems with the use of cut points and correlated assessments. Two simulations are provided in which the correlational structure of a set of cognitive and achievement data are simulated from a single population with no categorical structures. The simulations produce profiles remarkably similar to reported profile differences, suggesting that the patterns are a product of the cut point and the correlational structure of the data. If dimensional approaches better fit the attributes of learning disability, new conceptualizations and better methods to identification and intervention may emerge, especially for comorbid associations of reading and math difficulties.

  16. Three-axis accelerometer package for slimhole and microhole seismic monitoring and surveys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunter, S.L.; Harben, P.E.

    1997-01-07

    The development of microdrilling technology, nominally defined as drilling technology for 1-in.-diameter boreholes, shows potential for reducing the cost of drilling monitoring wells. A major question that arises in drilling microholes is if downhole logging and monitoring in general--and downhole seismic surveying in particular--can be conducted in such small holes since the inner working diameter of such a seismic tool could be as small as 0.31 in. A downhole three-component accelerometer package that fits within a 031-in. inner diameter tube has been designed, built, and tested. The package consists of three orthogonally mounted Entran EGA-125-5g piezoresistive silicon micromachined accelerometers withmore » temperature compensation circuitry, downhole amplification, and line drivers mounted in a thin-walled aluminum tube. Accelerometers are commercially available in much smaller package sizes than conventional geophones, but the noise floor is significantly higher than that for the geophones. Cross-well tests using small explosives showed good signal-to-noise ratio in the recorded waveform at various receiver depths with a 1,50-ft source-receiver well separation. For some active downhole surveys, the accelerometer unit would clearly be adequate. It can be reasonably assumed, however, that for less energetic sources and for greater well separations, the high accelerometer noise floor is not acceptable. By expanding the inner working diameter of a microhole seismic tool to 0.5 in., other commercial accelerometers can be used with substantially lower noise floors.« less

  17. Calibration of Swarm accelerometer data by GPS positioning and linear temperature correction

    NASA Astrophysics Data System (ADS)

    Bezděk, Aleš; Sebera, Josef; Klokočník, Jaroslav

    2018-07-01

    Swarm, a mission of the European Space Agency, consists of three satellites orbiting the Earth since November 2013. In addition to the instrumentation aimed at fulfilling the mission's main goal, which is the observation of Earth's magnetic field, each satellite carries a geodetic quality GPS receiver and an accelerometer. Initially put in a 500-km altitude, all Swarm spacecraft slowly decay due to the action of atmospheric drag. Atmospheric particles and radiation forces impinge on the satellite's surface and thus create the main part of the nongravitational force, which together with satellite-induced thrusts can be measured by space accelerometers. Unfortunately, the Swarm accelerometer data are heavily disturbed by the varying onboard temperature. We calibrate the accelerometer data against a calibration standard derived from observed GPS positions, while making use of the models to represent the forces of gravity origin. We show that this procedure can be extended to incorporate the temperature signal. The obtained calibrated accelerations are validated in several different ways; namely by (i) physically modelled nongravitational forces, by (ii) intercomparison of calibrated accelerometer data from two Swarm satellites flying side-by-side, and by (iii) good agreement of our calibrated signals with those released by ESA, obtained via a different approach for reducing temperature effects. Finally, the presented method is applied to the Swarm C accelerometer data set covering almost two years (July 2014-April 2016), which ESA recently released to scientific users.

  18. Electrostatic Accelerometer for the Gravity Recovery and Climate Experiment Follow-On Mission (GRACE FO)

    NASA Astrophysics Data System (ADS)

    Lebat, V.; Foulon, B.; Christophe, B.

    2013-12-01

    The GRACE FO mission, led by the JPL (Jet Propulsion Laboratory), is an Earth-orbiting gravity mission, continuation of the GRACE mission, that will produce an accurate model of the Earth's gravity field variation providing global climatic data during five year at least. The mission involves two satellites in a loosely controlled tandem formation, with a micro-wave link measuring the inter-satellites distance variation. Non-uniformities in the distribution of the Earth's mass cause the distance between the two satellites to vary. This variation is measured to recover gravity, after subtracting the non-gravitational contributors, as the residual drag. ONERA (the French Aerospace Lab) is developing, manufacturing and testing electrostatic accelerometers measuring this residual drag applied on the satellites. The accelerometer is composed of two main parts: the Sensor Unit (including the Sensor Unit Mechanics and the Front-End Electronic Unit) and the Interface Control Unit. In the Accelerometer Core, located in the Sensor Unit Mechanics, the proof mass is levitated and maintained in a center of an electrode cage by electrostatic forces. Thus, any drag acceleration applied on the satellite involves a variation on the servo-controlled electrostatic suspension of the mass. The voltage on the electrodes providing this electrostatic force is the measurement output of the accelerometer. The impact of the accelerometer defaults (geometry, electronic and parasitic forces) leads to bias, misalignment and scale factor error, non-linearity and noise. Some of these accelerometer defaults are characterized by tests with micro-gravity pendulum bench and with drops in ZARM catapult. Besides, a thermal stability is needed for the accelerometer core and front-end electronics to avoid bias and scale factor variation, and reached by a thermal box designed by Astrium, spacecraft manufacturer. The accelerometers are designed to endure the launch vibrations and the thermal environment at ground and in orbit. As the measure must be accurate, no sliding of the core must appear in regard of the accelerometer external reference. To ensure the thermal core stability, the electrode cage of the core is made of glass material (ULE), which is very critical, in particular due to the free motion of the proof-mass during the launch. To assess the design of the accelerometer in particular the critical parts of the core, specific analysis is realized to ensure mechanical behavior. The design of electrostatic accelerometer of the GRACE Follow-On mission benefits of the GRACE heritage, GOCE launched in 2009 and MICROSCOPE which will be launched in 2016, including some improvement to improve the performance, in particular the thermal sensitivity of the measurements. The Preliminary Design Review of electronics was achieved successfully on July 2013, and the PDR of the whole instrument is forecasted on November 2013. The integration of the Engineering Model will begin on October 2013 and its status will be presented.

  19. Relation of nutritional status to physiological outcomes after cardiac surgery in elderly patients with diabetes mellitus: a preliminary study.

    PubMed

    Izawa, Kazuhiro P; Watanabe, Satoshi

    2016-12-01

    To determine differences in physiological outcome (PO) based on the Geriatric Nutritional Risk Index (GNRI) and cut-off values for PO according to the GNRI in elderly post-cardiac surgery patients complicated by diabetes mellitus (DM). Thirty-five patients (72.9 years) were enrolled and divided by GNRI. Patient characteristics and PO of handgrip strength (HG), knee extensor muscle strength (KEMS), maximum gait speed (GS), and one-leg standing time (OLST) were compared between the groups, and cut-off values for PO were determined. These POs were significantly lower in the low-GNRI group (<92 points) than in the high-GNRI (≥92 points) group. The cut-off values for PO were HG, 22.7 kgf; KEMS, 41.5 %BW; GS, 1.2 m/sec; and OLST, 6.7 s. Nutritional status might influence PO following cardiac surgery. The cut-off values of PO reported here might be indicative of the need to improve patient nutritional status.

  20. The X-point effects on the peeling-ballooning stability conditions

    NASA Astrophysics Data System (ADS)

    Zheng, Linjin

    2017-10-01

    Due to the X-point singularity the safety factor tends to infinity as the last closed flux surface is approached. The usual numerical treatment of X-point singularity is to cut off a small fraction of edge region for system stability evaluation or simply use an up-down symmetric equilibrium without X-point included. This type of treatments have been used to make the peeling-ballooning stability diagram. We found that the mode types, peel or ballooning, can vary depending on how much the edge portion is cut off. When the cutting-off leads the edge safety factor (qa) to become close to a mode rational number, the peeling modes dominate; otherwise the ballooning type of modes prevail. The stability condition for peeling modes with qa being close to a rational number is much stringent than that for ballooning type of modes. Because qa tends to infinite near the separatrix, the mode rational surfaces are concentrated in the plasma region and thus the peeling modes are basically excluded. This extrapolation indicates that the stability boundary for high edge current, which is related to the peeling modes, need to be reexamined to take into account the X-point effects. Supported by U. S. Department of Energy, Office of Fusion Energy Science: Grant No. DE-FG02-04ER-54742.

  1. Utility of the T-SPOT®.TB test's borderline category to increase test resolution for results around the cut-off point.

    PubMed

    Rego, Karen; Pereira, Kristen; MacDougall, James; Cruikshank, William

    2018-01-01

    Accurate identification of individuals with TB infection, is required to achieve the WHO's End TB Strategy goals. While there is general acceptance that the T-SPOT.TB test borderline category provides an opportunity to increase test resolution of results around the test cut-off point, this has not been investigated. 645,947 tests were analyzed to determine frequency of borderline results, effect of age and time between tests and associations between subjects' clinical risk factors and retest results. 645,947 tests produced 93.5% negatives, 4% positives, 0.6% invalids, and 1.8% borderlines. Within the borderline results, 5044 were repeated, with 59.2%, 20.0% and 20.2% resolving to negative, positive and borderline, respectively. Age of subject did not affect retest results; however, time between tests indicated that retest resolution occurred with greatest frequency after 90 days. TB risk factors were provided for 2640 subjects and 17% of low risk subjects with a high initial borderline resolved to negative while 27.6% of subjects with high risk and an initial low borderline resolved to positive, suggesting that these subjects could have been inappropriately classified if using a single cut-off point test with no borderline category. This study demonstrates the utility of the T-SPOT.TB test's borderline category to increase test resolution around the test cut-off point. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. The Telephone Interview for Cognitive Status: Creating a crosswalk with the Mini-Mental State Exam

    PubMed Central

    Fong, Tamara G.; Fearing, Michael A.; Jones, Richard N.; Shi, Peilin; Marcantonio, Edward R.; Rudolph, James L.; Yang, Frances M.; Kiely, Dan K.; Inouye, Sharon K.

    2009-01-01

    Background Brief cognitive screening measures are valuable tools for both research and clinical applications. The most widely used instrument, the Mini-Mental State Examination (MMSE) is limited in that it must be administered face-to-face, cannot be used in participants with visual or motor impairments, and is protected by copyright. Alternative screening instruments, such as the Telephone Interview for Cognitive Status (TICS) have been developed and may provide a valid alternative with comparable cut point scores to rate global cognitive function. Methods MMSE, TICS-30, and TICS-40 scores from 746 community dwelling elders who participated in the Aging, Demographics, and Memory Study (ADAMS) were analyzed with equipercentile equating, a statistical process of determining comparable scores based on percentile equivalents on different forms of an examination. Results Scores from the MMSE and the TICS-30 and TICS-40 corresponded well and clinically relevant cut point scores were determined; for example, an MMSE score of 23 is equivalent to 17 and 20 on the TICS-30 and TICS-40, respectively. Conclusions These findings provide scores that can be used to link TICS and MMSE scores directly. Clinically relevant and important MMSE cut points and the respective ADAMS TICS-30 and TICS-40 cut point scores have been included to identify the degree of cognitive impairment among respondents with any type of cognitive disorder. These results will help with the widespread application of the TICS in both research and clinical practice. PMID:19647495

  3. [Usefulness of a screening questionnaire for post traumatic stress in a Colombian population].

    PubMed

    Pineda, D A; Guerrero, O L; Pinilla, M L; Estupiñán, M

    Rating scales for post traumatic stress disorder (PTSD) should be consistents with DSM IV criteria, and should be validate for each culture. To validate a PTSD checklist in a Colombian little town population, which was semi destructed by a guerrilla attack. A stratified, representative and randomized sample of 202 adult participants, aged over 15 year old, was selected from San Joaquin (Santander Colombia) two year after an guerrilla attack. A structured interview (SCID I), based on DSM IV criteria, was developed with each member of the sample. 76 participants (37.6%) met criteria for PTSD, and 126 (62.4%) were classified as non PTSD. A rating checklist with 24 symptoms of PTSD was applied by self report. Each item of the scale was scored 1 to 4. PTSD checklist had a reliability Cronbach s alpha coefficient of 0.97. PTSD group scored 70.4 22.9, and non PTSD 37.2 13.7 (p< 0.0001) on the PTSD checklist. A discriminant analysis found that the scale had a correctly classification capability of 88.6% (p< 0.0001). Sensibility was found between 76.3% for a cut off point of 51 and 81.6% for cut off point of 45. Specificity changed between 71.4% for a cut off point of 45 and 84.4% for a cut off point of 51. Checklist for PTSD had a high reliability, good discriminant capability, and good sensibility and specificity.

  4. Tactile Sensors for Palm-Size Crawling Robots

    DTIC Science & Technology

    2014-05-01

    lamination and laser cutting . For the sensor array discussed in this report, the hairs have an average normal sensitivity of approximately 0.8 grams/hair, but...Adhesive (M) Hair Mounting Layer. For visualization purposes, layers I and M are shown with laser - cut features that are actually formed after...The levers are then partially freed from the structure via laser - cutting . The levers are left partly connected at this point so that the hairs (L) can

  5. Detecting Human Activity Using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors

    DTIC Science & Technology

    2011-09-01

    Detecting Human Activity using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors by Sarah H. Walker and Geoffrey H. Goldman...Adelphi, MD 20783-1197 ARL-TR-5729 September 2011 Detecting Human Activity using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors...DD-MM-YYYY) September 2011 2. REPORT TYPE 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Detecting Human Activity using Acoustic

  6. Physical Activity and Adiposity Markers at Older Ages: Accelerometer Vs Questionnaire Data

    PubMed Central

    Sabia, Séverine; Cogranne, Pol; van Hees, Vincent T.; Bell, Joshua A.; Elbaz, Alexis; Kivimaki, Mika; Singh-Manoux, Archana

    2015-01-01

    Objective Physical activity is critically important for successful aging, but its effect on adiposity markers at older ages is unclear as much of the evidence comes from self-reported data on physical activity. We assessed the associations of questionnaire-assessed and accelerometer-assessed physical activity with adiposity markers in older adults. Design/Setting/Participants This was a cross-sectional study on 3940 participants (age range 60-83 years) of the Whitehall II study who completed a 20-item physical activity questionnaire and wore a wrist-mounted accelerometer for 9 days in 2012 and 2013. Measurements Total physical activity was estimated using metabolic equivalent hours/week for the questionnaire and mean acceleration for the accelerometer. Time spent in moderate-and-vigorous physical activity (MVPA) was also assessed by questionnaire and accelerometer. Adiposity assessment included body mass index, waist circumference, and fat mass index. Fat mass index was calculated as fat mass/height² (kg/m²), with fat mass estimated using bioimpedance. Results Greater total physical activity was associated with lower adiposity for all adiposity markers in a dose-response manner. In men, the strength of this association was 2.4 to 2.8 times stronger with the accelerometer than with questionnaire data. In women, it was 1.9 to 2.3 times stronger. For MVPA, questionnaire data in men suggested no further benefit for adiposity markers past 1 hour/week of activity. This was not the case for accelerometer-assessed MVPA where, for example, compared with men undertaking <1 hour/week of accelerometer-assessed MVPA, waist circumference was 3.06 (95% confidence interval 2.06–4.06) cm lower in those performing MVPA 1–2.5 hours/week, 4.69 (3.47–5.91) cm lower in those undertaking 2.5–4 hours/week, and 7.11 (5.93–8.29) cm lower in those performing ≥4 hours/week. Conclusions The association of physical activity with adiposity markers in older adults was stronger when physical activity was assessed by accelerometer compared with questionnaire, suggesting that physical activity might be more important for adiposity than previously estimated. PMID:25752539

  7. Are physical activity studies in Hispanics meeting reporting guidelines for continuous monitoring technology? A systematic review.

    PubMed

    Layne, Charles S; Parker, Nathan H; Soltero, Erica G; Rosales Chavez, José; O'Connor, Daniel P; Gallagher, Martina R; Lee, Rebecca E

    2015-09-18

    Continuous monitoring technologies such as accelerometers and pedometers are the gold standard for physical activity (PA) measurement. However, inconsistencies in use, analysis, and reporting limit the understanding of dose-response relationships involving PA and the ability to make comparisons across studies and population subgroups. These issues are particularly detrimental to the study of PA across different ethnicities with different PA habits. This systematic review examined the inclusion of published guidelines involving data collection, processing, and reporting among articles using accelerometers or pedometers in Hispanic or Latino populations. English (PubMed; EbscoHost) and Spanish (SCIELO; Biblioteca Virtual en Salud) articles published between 2000 and 2013 using accelerometers or pedometers to measure PA among Hispanics or Latinos were identified through systematic literature searches. Of the 253 abstracts which were initially reviewed, 57 met eligibility criteria (44 accelerometer, 13 pedometer). Articles were coded and reviewed to evaluate compliance with recommended guidelines (N = 20), and the percentage of accelerometer and pedometer articles following each guideline were computed and reported. On average, 57.1 % of accelerometer and 62.2 % of pedometer articles reported each recommended guideline for data collection. Device manufacturer and model were reported most frequently, and provision of instructions for device wear in Spanish was reported least frequently. On average, 29.6 % of accelerometer articles reported each guideline for data processing. Definitions of an acceptable day for inclusion in analyses were reported most frequently, and definitions of an acceptable hour for inclusion in analyses were reported least frequently. On average, 18.8 % of accelerometer and 85.7 % of pedometer articles included each guideline for data reporting. Accelerometer articles most frequently included average number of valid days and least frequently included percentage of wear time. Inclusion of standard collection and reporting procedures in studies using continuous monitoring devices in Hispanic or Latino population is generally low. Lack of reporting consistency in continuous monitoring studies limits researchers' ability to compare studies or draw meaningful conclusions concerning amounts, quality, and benefits of PA among Hispanic or Latino populations. Reporting data collection, computation, and decision-making standards should be required. Improved interpretability would allow practitioners and researchers to apply scientific findings to promote PA.

  8. Effort, symptom validity testing, performance validity testing and traumatic brain injury.

    PubMed

    Bigler, Erin D

    2014-01-01

    To understand the neurocognitive effects of brain injury, valid neuropsychological test findings are paramount. This review examines the research on what has been referred to a symptom validity testing (SVT). Above a designated cut-score signifies a 'passing' SVT performance which is likely the best indicator of valid neuropsychological test findings. Likewise, substantially below cut-point performance that nears chance or is at chance signifies invalid test performance. Significantly below chance is the sine qua non neuropsychological indicator for malingering. However, the interpretative problems with SVT performance below the cut-point yet far above chance are substantial, as pointed out in this review. This intermediate, border-zone performance on SVT measures is where substantial interpretative challenges exist. Case studies are used to highlight the many areas where additional research is needed. Historical perspectives are reviewed along with the neurobiology of effort. Reasons why performance validity testing (PVT) may be better than the SVT term are reviewed. Advances in neuroimaging techniques may be key in better understanding the meaning of border zone SVT failure. The review demonstrates the problems with rigidity in interpretation with established cut-scores. A better understanding of how certain types of neurological, neuropsychiatric and/or even test conditions may affect SVT performance is needed.

  9. Mathematical Modeling of Thermofrictional Milling Process Using ANSYS WB Software

    NASA Astrophysics Data System (ADS)

    Sherov, K. T.; Sikhimbayev, M. R.; Sherov, A. K.; Donenbayev, B. S.; Rakishev, A. K.; Mazdubai, A. B.; Musayev, M. M.; Abeuova, A. M.

    2017-06-01

    This article presents ANSYS WB-based mathematical modelling of the thermofrictional milling process, which allowed studying the dynamics of thermal and physical processes occurring during the processing. The technique used also allows determination of the optimal cutting conditions of thermofrictional milling for processing various materials, in particular steel 40CN2MA, 30CGSA, 45, 3sp. In our study, from among a number of existing models of cutting fracture, we chose the criterion first proposed by prof. V. L. Kolmogorov. In order to increase the calculations performance, a mathematical model was proposed, that used only two objects: a parallelepiped-shaped workpiece and a cutting insert in the form of a pentagonal prism. In addition, the work takes into account the friction coefficient between a cutting insert and a workpiece taken equal to 0.4 mm. To determine the temperature in the subcontact layer of the workpiece, we introduced the coordinates of nine characteristic points with the same interval in the local coordinate system. As a result, the temperature values were obtained for different materials at the studied points during the cutter speed change. The research results showed the possibility of controlling thermal processes during processing by choosing the optimum cutting modes.

  10. Poles of the S-matrix in Woods-Saxon and Salamon-Vertse potentials

    NASA Astrophysics Data System (ADS)

    Vertse, T.; Lovas, R. G.; Salamon, P.; Rácz, A.

    2012-10-01

    The motions of the l = 0 poles of the S-matrix with varying potential strength is calculated in a cut-off Woods-Saxon (CWS) potential and in the Salamon-Vertse (SV) potential [3]. Both potentials are zero beyond a certain finite distance but the CWS potential has a jump at the cut while the SV potential goes to zero smoothly. The jump of the CWS potential might cause a strange circling of the trajectories at their starting region. This feature does not appear with the SV potential. Starting points of the trajectories depend on the ranges of the potentials. For CWS these points do depend on the unphysical cut-off radius. In this respect the SV potential seems to be superior to the CWS potential.

  11. Shaping Cutter Original Profile for Fine-module Ratchet Teeth Cutting

    NASA Astrophysics Data System (ADS)

    Sharkov, O. V.; Koryagin, S. I.; Velikanov, N. L.

    2018-03-01

    The methods for determining geometric characteristics of a theoretical original profile of the cutter for cutting ratchet teeth with a module of 0.3–1.0 mm are considered in the article. Design models describing the shaping process of cutting edges of cutter teeth are developed. Systems of expressions for determining coordinates of the points of front and back edges of cutter teeth; the workpiece angles of rotation during the cutting process; the minimum cutter radius are received. The basic data when using the proposed technique are: radii of circumferences passing through cavities of cutter teeth and external cut teeth; the gradient angle and length of straight section of the front edge of a cut tooth; angles of rotation of the cutter and the workpiece at the moment of shaping.

  12. Optimization of Machining Parameters of Milling Operation by Application of Semi-synthetic oil based Nano cutting Fluids

    NASA Astrophysics Data System (ADS)

    Giri Prasad, M. J.; Abhishek Raaj, A. S.; Rishi Kumar, R.; Gladson, Frank; M, Gautham

    2016-09-01

    The present study is concerned with resolving the problems pertaining to the conventional cutting fluids. Two samples of nano cutting fluids were prepared by dispersing 0.01 vol% of MWCNTs and a mixture of 0.01 vol% of MWCNTs and 0.01 vol% of nano ZnO in the soluble oil. The thermophysical properties such as the kinematic viscosity, density, flash point and the tribological properties of the prepared nano cutting fluid samples were experimentally investigated and were compared with those of plain soluble oil. In addition to this, a milling process was carried by varying the process parameters and by application of different samples of cutting fluids and an attempt was made to determine optimal cutting condition using the Taguchi optimization technique.

  13. 15 CFR 922.150 - Boundary.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND COASTAL RESOURCE MANAGEMENT NATIONAL... point due west of the mouth of the Copalis River cutting across the heads of Nitnat, Juan de Fuca and... Federally managed lands cutting across the mouths of all rivers and streams, except where adjacent to Indian...

  14. 15 CFR 922.150 - Boundary.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND COASTAL RESOURCE MANAGEMENT NATIONAL... point due west of the mouth of the Copalis River cutting across the heads of Nitnat, Juan de Fuca and... Federally managed lands cutting across the mouths of all rivers and streams, except where adjacent to Indian...

  15. 15 CFR 922.150 - Boundary.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND COASTAL RESOURCE MANAGEMENT NATIONAL... point due west of the mouth of the Copalis River cutting across the heads of Nitnat, Juan de Fuca and... Federally managed lands cutting across the mouths of all rivers and streams, except where adjacent to Indian...

  16. Micromachined force-balance feedback accelerometer with optical displacement detection

    DOEpatents

    Nielson, Gregory N.; Langlois, Eric; Baker, Michael; Okandan, Murat; Anderson, Robert

    2014-07-22

    An accelerometer includes a proof mass and a frame that are formed in a handle layer of a silicon-on-an-insulator (SOI). The proof mass is separated from the frame by a back-side trench that defines a boundary of the proof mass. The accelerometer also includes a reflector coupled to a top surface of the proof mass. An optical detector is located above the reflector at the device side. The accelerometer further includes at least one suspension spring. The suspension spring has a handle anchor that extends downwards from the device side to the handle layer to mechanically support upward and downward movement of the proof mass relative to a top surface of the proof mass.

  17. Hybridizing matter-wave and classical accelerometers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lautier, J.; Volodimer, L.; Hardin, T.

    2014-10-06

    We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performance without any isolation platform. Second, a servo-lock of the DC component of the conventional sensor output signal by the atomic one realizes a hybrid sensor. This method paves the way for applications in geophysics and in inertial navigation as it overcomes the main limitation of atomicmore » accelerometers, namely, the dead times between consecutive measurements.« less

  18. Mapping GRACE Accelerometer Error

    NASA Astrophysics Data System (ADS)

    Sakumura, C.; Harvey, N.; McCullough, C. M.; Bandikova, T.; Kruizinga, G. L. H.

    2017-12-01

    After more than fifteen years in orbit, instrument noise, and accelerometer noise in particular, remains one of the limiting error sources for the NASA/DLR Gravity Recovery and Climate Experiment mission. The recent V03 Level-1 reprocessing campaign used a Kalman filter approach to produce a high fidelity, smooth attitude solution fusing star camera and angular acceleration data. This process provided an unprecedented method for analysis and error estimation of each instrument. The accelerometer exhibited signal aliasing, differential scale factors between electrode plates, and magnetic effects. By applying the noise model developed for the angular acceleration data to the linear measurements, we explore the magnitude and geophysical pattern of gravity field error due to the electrostatic accelerometer.

  19. Testing of an actively damped boring bar featuring structurally integrated PZT stack actuators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Redmond, J.; Barney, P.

    This paper summarizes the results of cutting tests performed using an actively damped boring bar to minimize chatter in metal cutting. A commercially available 2 inch diameter boring bar was modified to incorporate PZT stack actuators for controlling tool bending vibrations encountered during metal removal. The extensional motion of the actuators induce bending moments in the host structure through a two-point preloaded mounting scheme. Cutting tests performed at various speeds and depths of cuts on a hardened steel workpiece illustrate the bar`s effectiveness toward eliminating chatter vibrations and improving workpiece surface finish.

  20. Psychological distress of residents in Kawauchi village, Fukushima Prefecture after the accident at Fukushima Daiichi Nuclear Power Station: the Fukushima Health Management Survey.

    PubMed

    Yoshida, Koji; Shinkawa, Tetsuko; Urata, Hideko; Nakashima, Kanami; Orita, Makiko; Yasui, Kiyotaka; Kumagai, Atsushi; Ohtsuru, Akira; Yabe, Hirooki; Maeda, Masaharu; Hayashida, Naomi; Kudo, Takashi; Yamashita, Shunichi; Takamura, Noboru

    2016-01-01

    To shed light on the mental health of evacuees after the accident at Fukushima Daiichi Nuclear Power Station (FDNPS), we evaluate the results of the Fukushima Health Management Survey (FHMS) of the residents at Kawauchi village in Fukushima, which is located less than 30 km from the FDNPS. We conducted the cross-sectional study within the framework of the FHMS. Exposure values were "anorexia," "subjective feelings about health," "feelings about sleep satisfaction," and "bereavement caused by the disaster," confounding variables were "age" and "sex," and outcome variables were "K6 points." We collected data from the FHMS, and employed the Kessler Psychological Distress Scale (K6) and the posttraumatic stress disorder (PTSD) Checklist Stressor-Specific Version (PCL-S) to carry out the research. A total of 13 or greater was the cut-off for identifying serious mental illness using the K6 scale. The study subjects included residents (n = 542) of over 30 years of age from Kawauchi village, and data were used from the period of January 1, 2012 to October 31, 2012. A total of 474 residents (87.5%) scored less than 13 points in the K6 and 68 (12.6%) scored 13 points or more. The proportion of elderly residents (over 65 years old) among people with K6 score above the cut-off was higher than that among people with K6 score below the cut-off (44.1 vs 31.0%, p < 0.05). In addition, the proportion of residents with anorexia and mental illness among people with K6 score above the cut-off was higher than among people with K6 score below the cut-off (p < 0.001 and p < 0.05, respectively). The amount of residents who scored 44 points or more in the PCL-S among people with K6 score above the cut-off was also considerably higher than among people with K6 score below the cut-off (79.4 vs 12.9%, p < 0.001). Interestingly, the proportion of residents who scored more than among people with K6 score above the cut-off and the among people with PCL-S score above the cut-off in Kawauchi was higher than in previous studies in other locations. These results suggest that there are severe mental health problems, such as depression and PTSD, among adults as a consequence of the accident at the FDNPS. Our study showed that residents who lived in the evacuation zone before the disaster are at high risk psychological distress. To facilitate local residents' recovery from Fukushima, there is a need to continue providing them with physical and mental support, as well as communication regarding the health risks of radiation.

  1. Prevalence of suspected developmental delays in early infancy: results from a regional population-based longitudinal study.

    PubMed

    Valla, Lisbeth; Wentzel-Larsen, Tore; Hofoss, Dag; Slinning, Kari

    2015-12-17

    Prevalence estimates on suspected developmental delays (SDD) in young infants are scarce and a necessary first step for planning an early intervention. We investigated the prevalence of SDD at 4, 6 and 12 months, in addition to associations of SDD with gender, prematurity and maternal education. This study is based on a Norwegian longitudinal sample of 1555 infants and their parents attending well-baby clinics for regular health check-ups. Moreover, parents completed the Norwegian translation of the Ages and Stages Questionnaires (ASQ) prior to the check-up, with a corrected gestational age being used to determine the time of administration for preterm infants. Scores ≤ the established cut-offs in one or more of the five development areas: communication, gross motor, fine motor, problem solving and personal-social, which defined SDD for an infant were reported. Chi-square tests were performed for associations between the selected factors and SDD. According to established Norwegian cut-off points, the overall prevalence of SDD in one or more areas was 7.0 % (10.3 % US cut-off) at 4 months, 5.7 % (12.3 % US cut-off) at 6 months and 6.1 % (10.3 % US cut-off) at 12 months. The highest prevalence of SDD was in the gross motor area at all three time points. A gestational age of < 37 weeks revealed a significant association with the communication SDD at 4 months, and with the fine motor and personal social SDD at 6 months. Gender was significantly associated with the fine motor and problem solving SDD at 4 months and personal- social SDD at 6 months: as more boys than girls were delayed. No significant associations were found between maternal education and the five developmental areas of the ASQ. Our findings indicate prevalence rates of SDD between 5.7 and 7.0 % in Norwegian infants between 4 and 12 months of age based on the Norwegian ASQ cut-off points (10.3-12.3 %, US cut-off points). During the first year of life, delay is most frequent within the gross motor area. Special attention should be paid to infants born prematurely, as well as to boys. Separate norms for boys and girls should be considered for the ASQ.

  2. Accuracy of the WHO’s body mass index cut-off points to measure gender- and age-specific obesity in middle-aged adults living in the city of Rio de Janeiro, Brazil

    PubMed Central

    Wollner, Materko; Paulo Roberto, Benchimol-Barbosa; Alysson Roncally, Silva Carvalho; Jurandir, Nadal; Edil, Luis Santos

    2017-01-01

    Introduction. Obesity is defined by the World Health Organization (WHO) as a disease characterized by the excessive accumulation of body fat. Obesity is considered a public health problem, leading to serious social, psychological and physical problems. However, the appropriate cut-off point of body mass index (BMI) based on body fat percentage (BF%) for classifying an individual as obese in middle-aged adults living in Rio de Janeiro remains unclear. Materials and methods. This was a prospective cross-sectional study comprising of 856 adults (413 men and 443 women) living in Rio de Janeiro, Brazil ranging from 30-59 years of age. The data were collected over a two year period (2010-2011), and all participants were underwent anthropometric evaluation. The gold standard was the percentage of body fat estimated by bioelectrical impedance analysis. The optimal sensitivity and specificity were attained by adjusting BMI cut-off values to predict obesity based on the WHO criteria: BF% >25% in men and >35% in women, according to the receiver operating characteristic curve (ROC) analysis adjusted for age and for the whole group. Results. The BMI cut-offs for predicting BF% were 29.9 kg/m2 in men and 24.9 kg/m2 in women. Conclusions The BMI that corresponded to a BF% previously defining obesity was similar to that of other Western populations for men but not for women. Furthermore, gender and age specific cut-off values are recommended in this population. Significance for public health World Health Organization (WHO) defines obesity as a disease characterized by the excessive accumulation of body fat. Obesity is considered a public health problem, leading to serious social, psychological and physical problems. The WHO suggested cut-off point for obesity is a body mass index (BMI) of 30 kg/m2, which is associated with morbidity and mortality. An important issue in the debate over measuring obesity concerns the use of BMI to define obesity across different populations. However, it is not clear, what is an appropriate cut-off point of BMI based on body fat percentage (BF%) to classify an individual as obese within gender-age groups and to distinguish categories of BF% in middle-aged adults living in the city of Rio de Janeiro. PMID:29071256

  3. Identifying depression with the PHQ-2: A diagnostic meta-analysis.

    PubMed

    Manea, Laura; Gilbody, Simon; Hewitt, Catherine; North, Alice; Plummer, Faye; Richardson, Rachel; Thombs, Brett D; Williams, Bethany; McMillan, Dean

    2016-10-01

    There is interest in the use of very brief instruments to identify depression because of the advantages they offer in busy clinical settings. The PHQ-2, consisting of two questions relating to core symptoms of depression (low mood and loss of interest or pleasure), is one such instrument. A systematic review was conducted to identify studies that had assessed the diagnostic performance of the PHQ-2 to detect major depression. Embase, MEDLINE, PsychINFO and grey literature databases were searched. Reference lists of included studies and previous relevant reviews were also examined. Studies were included that used the standard scoring system of the PHQ-2, assessed its performance against a gold-standard diagnostic interview and reported data on its performance at the recommended (≥3) or an alternative cut-off point (≥2). After assessing heterogeneity, where appropriate, data from studies were combined using bivariate diagnostic meta-analysis to derive sensitivity, specificity, likelihood ratios and diagnostic odds ratios. 21 studies met inclusion criteria totalling N=11,175 people out of which 1529 had major depressive disorder according to a gold standard. 19 of the 21 included studies reported data for a cut-off point of ≥3. Pooled sensitivity was 0.76 (95% CI =0.68-0.82), pooled specificity was 0.87 (95% CI =0.82-0.90). However there was substantial heterogeneity at this cut-off (I(2)=81.8%). 17 studies reported data on the performance of the measure at cut-off point ≥2. Heterogeneity was I(2)=43.2% pooled sensitivity at this cut-off point was 0.91 (95% CI =0.85-0.94), and pooled specificity was 0.70 (95% CI =0.64-0.76). The generally lower sensitivity of the PHQ-2 at cut-off ≥3 than the original validation study (0.83) suggests that ≥2 may be preferable if clinicians want to ensure that few cases of depression are missed. However, in situations in which the prevalence of depression is low, this may result in an unacceptably high false-positive rate because of the associated modest specificity. These results, however, need to be interpreted with caution given the possibility of selectively reported cut-offs. Copyright © 2016. Published by Elsevier B.V.

  4. Investigation of Electrostatic Accelerometer in HUST for Space Science Missions

    NASA Astrophysics Data System (ADS)

    Bai, Yanzheng; Hu, Ming; Li, Gui; Liu, Li; Qu, Shaobo; Wu, Shuchao; Zhou, Zebing

    2014-05-01

    High-precision electrostatic accelerometers are significant payload in CHAMP, GRACE and GOCE gravity missions to measure the non-gravitational forces. In our group, space electrostatic accelerometer and inertial sensor based on the capacitive sensors and electrostatic control technique has been investigated for space science research in China such as testing of equivalence principle (TEPO), searching non-Newtonian force in micrometer range, satellite Earth's field recovery and so on. In our group, a capacitive position sensor with a resolution of 10-7pF/Hz1/2 and the μV/Hz1/2 level electrostatic actuator are developed. The fiber torsion pendulum facility is adopt to measure the parameters of the electrostatic controlled inertial sensor such as the resolution, and the electrostatic stiffness, the cross couple between different DOFs. Meanwhile, high voltage suspension and free fall methods are applied to verify the function of electrostatic accelerometer. Last, the engineering model of electrostatic accelerometer has been developed and tested successfully in space and preliminary results are present.

  5. Determination of shuttle orbiter center of gravity from flight measurements

    NASA Technical Reports Server (NTRS)

    Hinson, E. W.; Nicholson, J. Y.; Blanchard, R. C.

    1991-01-01

    Flight measurements of pitch, yaw, and roll rates and the resultant rotationally induced linear accelerations during three orbital maneuvers on Shuttle mission space transportation system (STS) 61-C were used to calculate the actual orbiter center-of-gravity location. The calculation technique reduces error due to lack of absolute calibration of the accelerometer measurements and compensates for accelerometer temperature bias and for the effects of gravity gradient. Accuracy of the technique was found to be limited by the nonrandom and asymmetrical distribution of orbiter structural vibration at the accelerometer mounting location. Fourier analysis of the vibration was performed to obtain the power spectral density profiles which show magnitudes in excess of 10(exp 4) ug (sup 2)/Hz for the actual vibration and over 500 ug (sup 2)/Hz for the filtered accelerometer measurements. The data from this analysis provide a characterization of the Shuttle acceleration environment which may be useful in future studies related to accelerometer system application and zero-g investigations or processes.

  6. Comparison of interferon-γ release assay to two cut-off points of tuberculin skin test to detect latent Mycobacterium tuberculosis infection in primary health care workers.

    PubMed

    de Souza, Fernanda Mattos; do Prado, Thiago Nascimento; Pinheiro, Jair dos Santos; Peres, Renata Lyrio; Lacerda, Thamy Carvalho; Loureiro, Rafaela Borge; Carvalho, Jose Américo; Fregona, Geisa; Dias, Elias Santos; Cosme, Lorrayne Beliqui; Rodrigues, Rodrigo Ribeiro; Riley, Lee Wood; Maciel, Ethel Leonor Noia

    2014-01-01

    An interferon-γ release assay, QuantiFERON-TB (QFT) test, has been introduced an alternative test for the diagnosis of latent Mycobacterium tuberculosis infection (LTBI). Here, we compared the performance of QFT with tuberculin skin test (TST) measured at two different cut-off points among primary health care work (HCW) in Brazil. A cross-sectional study was carried out among HCWs in four Brazilian cities with a known history of high incidence of TB. Results of the QFT were compared to TST results based on both ≥5 mm and ≥10 mm as cut-off points. We enrolled 632 HCWs. When the cut-off value of ≥10 mm was used, agreement between QFT and TST was 69% (k = 0.31), and when the cut-off of ≥5 mm was chosen, the agreement was 57% (k = 0.22). We investigated possible factors of discordance of TST vs QFT. Compared to the TST-/QFT- group, risk factors for discordance in the TST+/QFT- group with TST cut-off of ≥5 mm included age between 41-45 years [OR = 2.70; CI 95%: 1.32-5.51] and 46-64 years [OR = 2.04; CI 95%: 1.05-3.93], BCG scar [OR = 2.72; CI 95%: 1.40-5.25], and having worked only in primary health care [OR = 2.30; CI 95%: 1.09-4.86]. On the other hand, for the cut-off of ≥10 mm, BCG scar [OR = 2.26; CI 95%: 1.03-4.91], being a household contact of a TB patient [OR = 1.72; CI 95%: 1.01-2.92] and having had a previous TST [OR = 1.66; CI 95%: 1.05-2.62], were significantly associated with the TST+/QFT- group. No statistically significant associations were found among the TST-/QFT+ discordant group with either TST cut-off value. Although we identified BCG vaccination to contribute to the discordance at both TST cut-off measures, the current Brazilian recommendation for the initiation of LTBI treatment, based on information gathered from medical history, TST, chest radiograph and physical examination, should not be changed.

  7. Determinants of self-reported smoking and misclassification during pregnancy, and analysis of optimal cut-off points for urinary cotinine: a cross-sectional study

    PubMed Central

    Aurrekoetxea, Juan J; Murcia, Mario; Rebagliato, Marisa; López, María José; Castilla, Ane Miren; Santa-Marina, Loreto; Guxens, Mónica; Fernández-Somoano, Ana; Espada, Mercedes; Lertxundi, Aitana; Tardón, Adonina; Ballester, Ferran

    2013-01-01

    Objectives To estimate the prevalence and factors associated with smoking and misclassification in pregnant women from INMA (INfancia y Medio Ambiente, Environment and Childhood) project, Spain, and to assess the optimal cut-offs for urinary cotinine (UC) that best distinguish daily and occasional smokers with varying levels of second-hand smoke (SHS) exposure. Design We used logistic regression models to study the relationship between sociodemographic variables and self-reported smoking and misclassification (self-reported non-smokers with UC >50 ng/ml). Receiver operating characteristic (ROC) curves were used to calculate the optimal cut-off point for discriminating smokers. The cut-offs were also calculated after stratification among non-smokers by the number of sources of SHS exposure. The cut-off points used to discriminate smoking status were the level of UC given by Youden's index and for 50 and 100 ng/ml for daily smokers, or 25 and 50 ng/ml for occasional smokers. Participants At the third trimester of pregnancy, 2263 pregnant women of the INMA Project were interviewed between 2004 and 2008 and a urine sample was collected. Results Prevalence of self-reported smokers at the third trimester of pregnancy was 18.5%, and another 3.9% misreported their smoking status. Variables associated with self-reported smoking and misreporting were similar, including born in Europe, educational level and exposure to SHS. The optimal cut-off was 82 ng/ml (95% CI 42 to 133), sensitivity 95.2% and specificity 96.6%. The area under the ROC curve was 0.986 (95% CI 0.982 to 0.990). The cut-offs varied according to the SHS exposure level being 42 (95% CI 27 to 57), 82 (95% CI 46 to 136) and 106 ng/ml (95% CI 58 to 227) for not being SHS exposed, exposed to one, and to two or more sources of SHS, respectively. The optimal cut-off for discriminating occasional smokers from non-smokers was 27 ng/ml (95% CI 11 to 43). Conclusions Prevalence of smoking during pregnancy in Spain remains high. UC is a reliable biomarker for classifying pregnant women according to their smoking status. However, cut-offs would differ based on baseline exposure to SHS. PMID:23355667

  8. Determinants of self-reported smoking and misclassification during pregnancy, and analysis of optimal cut-off points for urinary cotinine: a cross-sectional study.

    PubMed

    Aurrekoetxea, Juan J; Murcia, Mario; Rebagliato, Marisa; López, María José; Castilla, Ane Miren; Santa-Marina, Loreto; Guxens, Mónica; Fernández-Somoano, Ana; Espada, Mercedes; Lertxundi, Aitana; Tardón, Adonina; Ballester, Ferran

    2013-01-24

    To estimate the prevalence and factors associated with smoking and misclassification in pregnant women from INMA (INfancia y Medio Ambiente, Environment and Childhood) project, Spain, and to assess the optimal cut-offs for urinary cotinine (UC) that best distinguish daily and occasional smokers with varying levels of second-hand smoke (SHS) exposure. We used logistic regression models to study the relationship between sociodemographic variables and self-reported smoking and misclassification (self-reported non-smokers with UC >50 ng/ml). Receiver operating characteristic (ROC) curves were used to calculate the optimal cut-off point for discriminating smokers. The cut-offs were also calculated after stratification among non-smokers by the number of sources of SHS exposure. The cut-off points used to discriminate smoking status were the level of UC given by Youden's index and for 50 and 100 ng/ml for daily smokers, or 25 and 50 ng/ml for occasional smokers. At the third trimester of pregnancy, 2263 pregnant women of the INMA Project were interviewed between 2004 and 2008 and a urine sample was collected. Prevalence of self-reported smokers at the third trimester of pregnancy was 18.5%, and another 3.9% misreported their smoking status. Variables associated with self-reported smoking and misreporting were similar, including born in Europe, educational level and exposure to SHS. The optimal cut-off was 82 ng/ml (95% CI 42 to 133), sensitivity 95.2% and specificity 96.6%. The area under the ROC curve was 0.986 (95% CI 0.982 to 0.990). The cut-offs varied according to the SHS exposure level being 42 (95% CI 27 to 57), 82 (95% CI 46 to 136) and 106 ng/ml (95% CI 58 to 227) for not being SHS exposed, exposed to one, and to two or more sources of SHS, respectively. The optimal cut-off for discriminating occasional smokers from non-smokers was 27 ng/ml (95% CI 11 to 43). Prevalence of smoking during pregnancy in Spain remains high. UC is a reliable biomarker for classifying pregnant women according to their smoking status. However, cut-offs would differ based on baseline exposure to SHS.

  9. MEMS SoC: observer-based coplanar gyro-free inertial measurement unit

    NASA Astrophysics Data System (ADS)

    Chen, Tsung-Lin; Park, Sungsu

    2005-09-01

    This paper presents a novel design of a coplanar gyro-free inertial measurement unit (IMU) that consists of seven to nine single-axis linear accelerometers, and it can be utilized to perform the six DOF measurements for an object in motion. Unlike other gyro-fee IMUs, this design uses redundant accelerometers and state estimation techniques to facilitate the in situ and mass fabrication for the employed accelerometers. The alignment error from positioning accelerometers onto a measurement unit and the fabrication cost of an IMU can greatly be reduced. The outputs of the proposed design are three linear accelerations and three angular velocities. As compared to other gyro-free IMUs, the proposed design uses less integral operation and thus improves its sensing resolution and drifting problem. The sensing resolution of a gyro-free IMU depends on the sensing resolution of the employed accelerometers as well as the size of the measurement unit. Simulation results indicate that the sensing resolution of the proposed design is 2° s-1 for the angular velocity and 10 μg for the linear acceleration when nine single-axis accelerometers, each with 10 μg sensing resolution, are deployed on a 4 inch diameter disc. Also, thanks to the iterative EKF algorithm, the angle estimation error is within 10-3 deg at 2 s.

  10. A microelectromechanical accelerometer fabricated using printed circuit processing techniques

    NASA Astrophysics Data System (ADS)

    Rogers, J. E.; Ramadoss, R.; Ozmun, P. M.; Dean, R. N.

    2008-01-01

    A microelectromechanical systems (MEMS) capacitive-type accelerometer fabricated using printed circuit processing techniques is presented. A Kapton polymide film is used as the structural layer for fabricating the MEMS accelerometer. The accelerometer proof mass along with four suspension beams is defined in the Kapton polyimide film. The proof mass is suspended above a Teflon substrate using a spacer. The deflection of the proof mass is detected using a pair of capacitive sensing electrodes. The top electrode of the accelerometer is defined on the top surface of the Kapton film. The bottom electrode is defined in the metallization on the Teflon substrate. The initial gap height is determined by the distance between the bottom electrode and the Kapton film. For an applied external acceleration (normal to the proof mass), the proof mass deflects toward or away from the fixed bottom electrode due to inertial force. This deflection causes either a decrease or increase in the air-gap height thereby either increasing or decreasing the capacitance between the top and the bottom electrodes. An example PCB MEMS accelerometer with a square proof mass of membrane area 6.4 mm × 6.4 mm is reported. The measured resonant frequency is 375 Hz and the Q-factor in air is 0.52.

  11. Accelerometer-Based Method for Extracting Respiratory and Cardiac Gating Information for Dual Gating during Nuclear Medicine Imaging

    PubMed Central

    Pänkäälä, Mikko; Paasio, Ari

    2014-01-01

    Both respiratory and cardiac motions reduce the quality and consistency of medical imaging specifically in nuclear medicine imaging. Motion artifacts can be eliminated by gating the image acquisition based on the respiratory phase and cardiac contractions throughout the medical imaging procedure. Electrocardiography (ECG), 3-axis accelerometer, and respiration belt data were processed and analyzed from ten healthy volunteers. Seismocardiography (SCG) is a noninvasive accelerometer-based method that measures accelerations caused by respiration and myocardial movements. This study was conducted to investigate the feasibility of the accelerometer-based method in dual gating technique. The SCG provides accelerometer-derived respiratory (ADR) data and accurate information about quiescent phases within the cardiac cycle. The correct information about the status of ventricles and atria helps us to create an improved estimate for quiescent phases within a cardiac cycle. The correlation of ADR signals with the reference respiration belt was investigated using Pearson correlation. High linear correlation was observed between accelerometer-based measurement and reference measurement methods (ECG and Respiration belt). Above all, due to the simplicity of the proposed method, the technique has high potential to be applied in dual gating in clinical cardiac positron emission tomography (PET) to obtain motion-free images in the future. PMID:25120563

  12. Feasibility of Frequency-Modulated Wireless Transmission for a Multi-Purpose MEMS-Based Accelerometer

    PubMed Central

    Sabato, Alessandro; Feng, Maria Q.

    2014-01-01

    Recent advances in the Micro Electro-Mechanical System (MEMS) technology have made wireless MEMS accelerometers an attractive tool for Structural Health Monitoring (SHM) of civil engineering structures. To date, sensors' low sensitivity and accuracy—especially at very low frequencies—have imposed serious limitations for their application in monitoring large-sized structures. Conventionally, the MEMS sensor's analog signals are converted to digital signals before radio-frequency (RF) wireless transmission. The conversion can cause a low sensitivity to the important low-frequency and low-amplitude signals. To overcome this difficulty, the authors have developed a MEMS accelerometer system, which converts the sensor output voltage to a frequency-modulated signal before RF transmission. This is achieved by using a Voltage to Frequency Conversion (V/F) instead of the conventional Analog to Digital Conversion (ADC). In this paper, a prototype MEMS accelerometer system is presented, which consists of a transmitter and receiver circuit boards. The former is equipped with a MEMS accelerometer, a V/F converter and a wireless RF transmitter, while the latter contains an RF receiver and a F/V converter for demodulating the signal. The efficacy of the MEMS accelerometer system in measuring low-frequency and low-amplitude dynamic responses is demonstrated through extensive laboratory tests and experiments on a flow-loop pipeline. PMID:25198003

  13. Feasibility of frequency-modulated wireless transmission for a multi-purpose MEMS-based accelerometer.

    PubMed

    Sabato, Alessandro; Feng, Maria Q

    2014-09-05

    Recent advances in the Micro Electro-Mechanical System (MEMS) technology have made wireless MEMS accelerometers an attractive tool for Structural Health Monitoring (SHM) of civil engineering structures. To date, sensors' low sensitivity and accuracy--especially at very low frequencies--have imposed serious limitations for their application in monitoring large-sized structures. Conventionally, the MEMS sensor's analog signals are converted to digital signals before radio-frequency (RF) wireless transmission. The conversion can cause a low sensitivity to the important low-frequency and low-amplitude signals. To overcome this difficulty, the authors have developed a MEMS accelerometer system, which converts the sensor output voltage to a frequency-modulated signal before RF transmission. This is achieved by using a Voltage to Frequency Conversion (V/F) instead of the conventional Analog to Digital Conversion (ADC). In this paper, a prototype MEMS accelerometer system is presented, which consists of a transmitter and receiver circuit boards. The former is equipped with a MEMS accelerometer, a V/F converter and a wireless RF transmitter, while the latter contains an RF receiver and a F/V converter for demodulating the signal. The efficacy of the MEMS accelerometer system in measuring low-frequency and low-amplitude dynamic responses is demonstrated through extensive laboratory tests and experiments on a flow-loop pipeline.

  14. Accelerometer-based step initiation control for gait-assist neuroprostheses.

    PubMed

    Foglyano, Kevin M; Schnellenberger, John R; Kobetic, Rudi; Lombardo, Lisa; Pinault, Gilles; Selkirk, Stephen; Makowski, Nathaniel S; Triolo, Ronald J

    2016-01-01

    Electrical activation of paralyzed musculature can generate or augment joint movements required for walking after central nervous system trauma. Proper timing of stimulation relative to residual volitional control is critical to usefully affecting ambulation. This study evaluates three-dimensional accelerometers and customized algorithms to detect the intent to step from voluntary movements to trigger stimulation during walking in individuals with significantly different etiologies, mobility limitations, manual dexterities, and walking aids. Three individuals with poststroke hemiplegia or partial spinal cord injury exhibiting varying gait deficits were implanted with multichannel pulse generators to provide joint motions at the hip, knee, and ankle. An accelerometer integrated into the external control unit was used to detect heel strike or walker movement, and wireless accelerometers were used to detect crutch strike. Algorithms were developed for each sensor location to detect intent to step to progress through individualized stimulation patterns. Testing these algorithms produced detection accuracies of at least 90% on both level ground and uneven terrain. All participants use their accelerometer-triggered implanted gait systems in the community; the validation/system testing was completed in the hospital. The results demonstrated that safe, reliable, and convenient accelerometer-based step initiation can be achieved regardless of specific gait deficits, manual dexterities, and walking aids.

  15. Associations of Accelerometer-Measured and Self-Reported Sedentary Time With Leukocyte Telomere Length in Older Women

    PubMed Central

    Shadyab, Aladdin H.; Macera, Caroline A.; Shaffer, Richard A.; Jain, Sonia; Gallo, Linda C.; LaMonte, Michael J.; Reiner, Alexander P.; Kooperberg, Charles; Carty, Cara L.; Di, Chongzhi; Manini, Todd M.; Hou, Lifang; LaCroix, Andrea Z.

    2017-01-01

    Abstract Few studies have assessed the association of sedentary time with leukocyte telomere length (LTL). In a cross-sectional study conducted in 2012–2013, we examined associations of accelerometer-measured and self-reported sedentary time with LTL in a sample of 1,481 older white and African-American women from the Women's Health Initiative and determined whether associations varied by level of moderate- to vigorous-intensity physical activity (MVPA). The association between sedentary time and LTL was evaluated using multiple linear regression models. Women were aged 79.2 (standard deviation, 6.7) years, on average. Self-reported sedentary time was not associated with LTL. In a model adjusting for demographic characteristics, lifestyle behaviors, and health-related factors, among women at or below the median level of accelerometer-measured MVPA, those in the highest quartile of accelerometer-measured sedentary time had significantly shorter LTL than those in the lowest quartile, with an average difference of 170 base pairs (95% confidence interval: 4, 340). Accelerometer-measured sedentary time was not associated with LTL in women above the median level of MVPA. Findings suggest that, on the basis of accelerometer measurements, higher sedentary time may be associated with shorter LTL among less physically active women. PMID:28100466

  16. A sensitivity analysis on the variability in accelerometer data processing for monitoring physical activity.

    PubMed

    Lee, Paul H

    2015-02-01

    Accelerometers are gaining popularity for measuring physical activity, but there are many different ways to process accelerometer data. A sensitivity analysis was conducted to study the effect of varying accelerometer data processing protocols on estimating the association between PA level and socio-demographic characteristics using the National Health and Nutrition Examination Survey (NHANES) accelerometer data. The NHANES waves 2003-2004 and 2005-2006 accelerometer data (n=14,072) were used to investigate the effect of changing the accelerometer non-wearing time and valid day definitions on the demographic composition of the filtered datasets and the association between physical activity (PA) and socio-demographic characteristics (sex, age, race, educational level, marital status). Under different filtering rules (minimum number of valid day and definition of non-wear time), the demographic characteristics of the final sample varied. The proportion of participants aged 20-29 decreased from 18.9% to 15.8% when the minimum number of valid days required increased from 1 to 4 (p for trend<0.001), whereas that for aged ≥70 years increased from 18.9% to 20.6% (p for trend<0.001). Furthermore, with different filters, the effect of these demographic variables and PA varied, with some variables being significant under certain filtering rules but becoming insignificant under some other rules. The sensitivity analysis showed that the significance of the association between socio-demographic variables and PA could be varied with the definition of non-wearing time and minimum number of valid days. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Modal Filtering for Control of Flexible Aircraft

    NASA Technical Reports Server (NTRS)

    Suh, Peter M.; Mavris, Dimitri N.

    2013-01-01

    Modal regulators and deformation trackers are designed for an open-loop fluttering wing model. The regulators are designed with modal coordinate and accelerometer inputs respectively. The modal coordinates are estimated with simulated fiber optics. The robust stability of the closed-loop systems is compared in a structured singular-value vector analysis. Performance is evaluated and compared in a gust alleviation and flutter suppression simulation. For the same wing and flight condition two wing-shape-tracking control architectures are presented, which achieve deformation control at any point on the wing.

  18. Physical Activity Assessment with the ActiGraph GT3X and Doubly Labeled Water.

    PubMed

    Chomistek, Andrea K; Yuan, Changzheng; Matthews, Charles E; Troiano, Richard P; Bowles, Heather R; Rood, Jennifer; Barnett, Junaidah B; Willett, Walter C; Rimm, Eric B; Bassett, David R

    2017-09-01

    To compare the degree to which four accelerometer metrics-total activity counts per day (TAC per day), steps per day (steps per day), physical activity energy expenditure (PAEE) (kcal·kg·d), and moderate- to vigorous-intensity physical activity (MVPA) (min·d)-were correlated with PAEE measured by doubly labeled water (DLW). Additionally, accelerometer metrics based on vertical axis counts and triaxial counts were compared. This analysis included 684 women and 611 men age 43 to 83 yr. Participants wore the Actigraph GT3X on the hip for 7 d twice during the study and the average of the two measurements was used. Each participant also completed one DLW measurement, with a subset having a repeat. PAEE was estimated by subtracting resting metabolic rate and the thermic effect of food from total daily energy expenditure estimated by DLW. Partial Spearman correlations were used to estimate associations between PAEE and each accelerometer metric. Correlations between the accelerometer metrics and DLW-determined PAEE were higher for triaxial counts than vertical axis counts. After adjusting for weight, age, accelerometer wear time, and fat free mass, the correlation between TAC per day based on triaxial counts and DLW-determined PAEE was 0.44 in women and 0.41 in men. Correlations for steps per day and accelerometer-estimated PAEE with DLW-determined PAEE were similar. After adjustment for within-person variation in DLW-determined PAEE, the correlations for TAC per day increased to 0.61 and 0.49, respectively. Correlations between MVPA and DLW-determined PAEE were lower, particularly for modified bouts of ≥10 min. Accelerometer measures that represent total activity volume, including TAC per day, steps per day, and PAEE, were more highly correlated with DLW-determined PAEE than MVPA using traditional thresholds and should be considered by researchers seeking to reduce accelerometer data to a single metric.

  19. The use of MP3 recorders to log data from equine hoof mounted accelerometers.

    PubMed

    Parsons, K J; Wilson, A M

    2006-11-01

    MP3 recorders are readily available, small, lightweight and low cost, providing the potential for logging analogue hoof mounted accelerometer signals for the characterisation of equine locomotion. These, however, require testing in practice. To test whether 1) multiple MP3 recorders can maintain synchronisation, giving the ability to synchronise independent recorders for the logging of multiple limbs simultaneously; and 2) features of a foot mounted accelerometer signal attributable to foot-on and foot-off can be accurately identified from horse foot mounted accelerometers logged directly into an MP3 recorder. Three experiments were performed: 1) Maintenance of synchronisation was assessed by counting the number of samples recorded by each of 4 MP3 recorders while mounted on a trotting horse and over 2 consecutive 30 min periods in 8 recorders on a bench. 2) Foot-on and foot-off times obtained from manual transcription of MP3 logged data and directly logged accelerometer signal were compared. 3) MP3/accelerometer acquisition units were used to log accelerometer signals from racehorses during extended training sessions. Mean absolute error of synchronisation between MP3 recorders was 10 samples per million (compared to mean number of samples, range 1-32 samples per million). Error accumulation showed a linear correlation with time. Features attributable to foot on and foot off were equally identifiable from the MP3 recorded signal over a range of equine gaits. Multiple MP3 recorders can be synchronised and used as a relatively cheap, robust, reliable and accurate logging system when combined with an accelerometer and external battery for the specific application of the measurement of stride timing variables across the range of equine gaits during field locomotion. Footfall timings can be used to identify intervals between the fore and hind contacts, the identification of diagonal advanced placement and to calculate stride timing variables (stance time, protraction time and stride time). These parameters are invaluable for the characterisation and assessment of equine locomotion.

  20. Criterion validity of the Physical Activity Questionnaire for Schoolchildren (PAQ-S) in assessing physical activity levels: the Healthy Growth Study.

    PubMed

    Manios, Y; Androutsos, O; Moschonis, G; Birbilis, M; Maragkopoulou, K; Giannopoulou, A; Argyri, E; Kourlaba, G

    2013-10-01

    The aim of this paper was to evaluate the criterion validity of the Physical Activity Questionnaire for Schoolchildren (PAQ-S). The current study is a subcohort of the Healthy Growth Study, a large-scale cross-sectional study. 202 schoolchildren aged 9-13 years from Greece completed the PAQ-S and wore an accelerometer for 4 consecutive days. Time spent moderate (MPA), moderate to vigorous (MVPA) and vigorous (VPA) physical activity was calculated based on PAQ-S and accelerometer data. The average time spent on MPA and MVPA as derived from PAQ-S and from accelerometers were significantly moderately correlated (r=0.462, P<0.001 and r=0.483, P<0.001, respectively). No significant correlation was detected between PAQ-S and accelerometer-measured time spent performing VPA (rho=0.150, P=0.057). Intraclass Correlation Coefficient (ICC) indicated a moderate agreement between PAQ-S and accelerometer in estimating MPA (ICC=0.592, P<0.001) and MVPA (ICC=0.581, P<0.001). Bland-Altman analysis revealed a small mean difference (the "bias"), between the two methods, in estimating MPA, although this difference was found to be significantly higher than zero ("bias"=27.4% of the accelerometer-measured mean score, P=0.006). On the other hand, Bland-Altman analysis revealed a large mean difference in estimating MVPA and VPA ("bias"=84.2% and 357% of the accelerometer-measured mean score for MVPA and VPA, respectively and P<0.001). The high correlation coefficient between the average and difference values between all physical activity scores derived from accelerometers and PAQ-S, indicate a systematic overestimation of physical activity time with increasing physical activity for PAQ-S. The validity of PAQ-S for the estimation of MPA and MVPA was found to be slightly similar self-reported measures for schoolchildren. Therefore, this questionnaire could be used as a tool for physical activity assessment in large population studies.

  1. Plugging the leak: barrier island restoration following Hurricane Katrina enhances larval retention and improves salinity regime for oysters in Mobile Bay, Alabama.

    PubMed

    Park, Kyeong; Powers, Sean P; Bosarge, George S; Jung, Hoon-Shin

    2014-03-01

    Changes in geomorphology of estuaries are common following major perpetuations such as hurricanes and may have profound impacts on biological systems. Hurricane Katrina in 2005 created a new pass, called Katrina Cut, halving Dauphin Island in Mobile Bay, Alabama. Significant decline in oyster population at Cedar Point Reef, the primary oyster harvest grounds in Mobile Bay, had persisted since then until the Cut was artificially closed in 2010. A bio-physical model for hydrodynamics and oyster larval transport was used to evaluate two potential mechanisms responsible for oyster population declines: salinity changes in the context of oyster habitat suitability and retention of oyster larvae. The model results revealed that when open Katrina Cut increased salinity at Cedar Point Reef. During high freshwater discharge, in particular, water exchange through Katrina Cut increased the bottom salinity from <5 psu to well over 15 (sometimes >20) psu during the tropic tides. Elevated salinities are associated with greater predation on oysters and higher disease incidence. The presence of the Katrina Cut also reduced larval retention in the spawning area regardless of tidal or river discharge conditions. We conclude that closing the Cut likely improved conditions for oysters within Mobile Bay and eastern Mississippi Sound and that these improved conditions have contributed to increased oyster landings. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Chatter reduction in boring process by using piezoelectric shunt damping with experimental verification

    NASA Astrophysics Data System (ADS)

    Yigit, Ufuk; Cigeroglu, Ender; Budak, Erhan

    2017-09-01

    Chatter is a self-excited type of vibration that develops during machining due to process-structure dynamic interactions resulting in modulated chip thickness. Chatter is an important problem as it results in poor surface quality, reduced productivity and tool life. The stability of a cutting process is strongly influenced by the frequency response function (FRF) at the cutting point. In this study, the effect of piezoelectric shunt damping on chatter vibrations in a boring process is studied. In piezoelectric shunt damping method, an electrical impedance is connected to a piezoelectric transducer which is bonded on cutting tool. Electrical impedance of the circuit consisting of piezoceramic transducer and passive shunt is tuned to the desired natural frequency of the cutting tool in order to maximize damping. The optimum damping is achieved in analytical and finite element models (FEM) by using a genetic algorithm focusing on the real part of the tool point FRF rather than the amplitude. Later, a practical boring bar is considered where the optimum circuit parameters are obtained by the FEM. Afterwards, the effect of the optimized piezoelectric shunt damping on the dynamic rigidity and absolute stability limit of the cutting process are investigated experimentally by modal analysis and cutting tests. It is both theoretically and experimentally shown that application of piezoelectric shunt damping results in a significant increase in the absolute stability limit in boring operations.

  3. Haircutting Guide for Cosmetology Students.

    ERIC Educational Resources Information Center

    Baker, Linda M.

    Intended for use at any point in a beauty culture course, this student manual on haircutting implements and techniques focuses on two basic haircuts--page and short summer cut--to describe and illustrate basic cutting and shaping techniques. There are four major sections in the manual: (1) Hairshaping Implements and Techniques (Implements Used In…

  4. Electrostatic Accelerometer for the Gravity Recovery and Climate Experiment Follow-On Mission (GRACE FO)

    NASA Astrophysics Data System (ADS)

    Perrot, Eddy; Christophe, Bruno; Foulon, Bernard; Boulanger, Damien; Liorzou, Françoise; Lebat, Vincent

    2013-04-01

    The GRACE FO mission, led by the JPL (Jet Propulsion Laboratory), is an Earth-orbiting gravity mission, continuation of the GRACE mission, that will produce an accurate model of the Earth's gravity field variation providing global climatic data during five year at least. The mission involves two satellites in a loosely controlled tandem formation, with a micro-wave link measuring the inter-satellites distance variation. Non-uniformities in the distribution of the Earth's mass cause the distance between the two satellites to vary. This variation is measured to recover gravity, after substracting the non-gravitational contributors, as the residual drag. ONERA (the French Aerospace Lab) is developing and manufacturing electrostatic accelerometers measuring this residual drag applied on the satellites. The accelerometer is composed of two main parts: the Sensor Unit (including the Sensor Unit Mechanics and the Front-End Electronic Unit) and the Interface Control Unit. In the Accelerometer Core, located in the Sensor Unit Mechanics, the proof mass is levitated and maintained in a center of an electrode cage by electrostatic forces. Thus, any drag acceleration applied on the satellite involves a variation on the servo-controlled electrostatic suspension of the mass. The voltage on the electrodes providing this electrostatic force is the measurement output of the accelerometer. The impact of the accelerometer defaults (geometry, electronic and parasitic forces) leads to bias, misalignment and scale factor error, non-linearity and noise. Some of these accelerometer defaults are characterized by tests with micro-gravity pendulum bench and with drops in ZARM catapult. Besides, a thermal stability is needed for the accelerometer core and front-end electronics to avoid bias and scale factor variation. To reach this stability, the sensor unit is enclosed in a thermal box designed by Astrium, spacecraft manufacturer. The accelerometers are designed to endure mechanical excitation especially due to launching vibrations. As the measure must be accurate, no displacements or sliding must appear during excitations. The electrode cage is made of glass material (ULE), which is very critical, in particular due to the free motion of the proof-mass during the launch. Specific analysis on this part is realized to ensure mechanical behavior. The design of electrostatic accelerometer of the GRACE Follow-On mission benefits of the GRACE heritage, GOCE launched in 2009 and MICROSCOPE which will be launched in 2016, including some improvement to win in performance, in particular the thermal sensitivity of the measurements.

  5. Physical activity and physical fitness of nursing home residents with cognitive impairment: A pilot study.

    PubMed

    Marmeleira, José; Ferreira, Soraia; Raimundo, Armando

    2017-12-15

    Physical activity and physical fitness are important for health, functional mobility and performance of everyday activities. To date, little attention has been given to physical activity and physical fitness among nursing home residents with cognitive impairment. Therefore, the main aim of this study was to examine physical activity behavior and physical fitness of institutionalized older adults with cognitive impairment and to investigate their interrelations. Forty-eight older adults with cognitive impairment (83.9±7.7years; 72.9% women) and 22 without cognitive impairment (82.2±8.8years; 54.5% women) participated. Physical activity was objectively assessed with accelerometers and physical fitness components (muscular strength, flexibility, balance, body composition and reaction time) were evaluated with physical fitness field tests. Nursing home residents with cognitive impairment spent only ~1min per day in moderate physical activity and ~89min in light physical activity. In average they accumulated 863 (±599) steps per day and spent 87.2% of the accelerometer wear time in sedentary behavior. Participants' physical fitness components were markedly low and according to the cut-offs used for interpreting the results a great number of nursing home residents had an increased risk of associated health problems, functional impairment and of falling. The performance in some physical fitness tests was positively associated with physical activity. Participants without cognitive impairment had higher levels of physical activity and physical fitness than their counterparts with cognitive impairment. These results indicate that nursing home residents, especially those with cognitive impairment, have low levels of physical activity, spent a high proportion of daytime in sedentary behavior and have low physical fitness. Nursing homes should implement health promotion strategies targeting physical activity and physical fitness of their residents. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Is Your Neighborhood Designed to Support Physical Activity? A Brief Streetscape Audit Tool.

    PubMed

    Sallis, James F; Cain, Kelli L; Conway, Terry L; Gavand, Kavita A; Millstein, Rachel A; Geremia, Carrie M; Frank, Lawrence D; Saelens, Brian E; Glanz, Karen; King, Abby C

    2015-09-03

    Macro level built environment factors (eg, street connectivity, walkability) are correlated with physical activity. Less studied but more modifiable microscale elements of the environment (eg, crosswalks) may also affect physical activity, but short audit measures of microscale elements are needed to promote wider use. This study evaluated the relation of a 15-item neighborhood environment audit tool with a full version of the tool to assess neighborhood design on physical activity in 4 age groups. From the 120-item Microscale Audit of Pedestrian Streetscapes (MAPS) measure of street design, sidewalks, and street crossings, we developed the 15-item version (MAPS-Mini) on the basis of associations with physical activity and attribute modifiability. As a sample of a likely walking route, MAPS-Mini was conducted on a 0.25-mile route from participant residences toward the nearest nonresidential destination for children (n = 758), adolescents (n = 897), younger adults (n = 1,655), and older adults (n = 367). Active transportation and leisure physical activity were measured with age-appropriate surveys, and accelerometers provided objective physical activity measures. Mixed-model regressions were conducted for each MAPS item and a total environment score, adjusted for demographics, participant clustering, and macrolevel walkability. Total scores of MAPS-Mini and the 120-item MAPS correlated at r = .85. Total microscale environment scores were significantly related to active transportation in all age groups. Items related to active transport in 3 age groups were presence of sidewalks, curb cuts, street lights, benches, and buffer between street and sidewalk. The total score was related to leisure physical activity and accelerometer measures only in children. The MAPS-Mini environment measure is short enough to be practical for use by community groups and planning agencies and is a valid substitute for the full version that is 8 times longer.

  7. Towards Integrated Marmara Strong Motion Network

    NASA Astrophysics Data System (ADS)

    Durukal, E.; Erdik, M.; Safak, E.; Ansal, A.; Ozel, O.; Alcik, H.; Mert, A.; Kafadar, N.; Korkmaz, A.; Kurtulus, A.

    2009-04-01

    Istanbul has a 65% chance of having a magnitude 7 or above earthquake within the next 30 years. As part of the preparations for the future earthquake, strong motion networks have been installed in and around Istanbul. The Marmara Strong Motion Network, operated by the Department of Earthquake Engineering of Kandilli Observatory and Earthquake Research Institute, encompasses permanent systems outlined below. It is envisaged that the networks will be run by a single entity responsible for technical management and maintanence, as well as for data management, archiving and dissemination through dedicated web-based interfaces. • Istanbul Earthquake Rapid Response and Early Warning System - IERREWS (one hundred 18-bit accelerometers for rapid response; ten 24-bit accelerometers for early warning) • IGDAŞ Gas Shutoff Network (100 accelerometers to be installed in 2010 and integrated with IERREWS) • Structural Monitoring Arrays - Fatih Sultan Mehmet Suspension Bridge (1200m-long suspension bridge across the Bosphorus, five 3-component accelerometers + GPS sensors) - Hagia Sophia Array (1500-year-old historical edifice, 9 accelerometers) - Süleymaniye Mosque Array (450-year-old historical edifice,9 accelerometers) - Fatih Mosque Array (237-year-old historical edifice, 9 accelerometers) - Kanyon Building Array (high-rise office building, 5 accelerometers) - Isbank Tower Array (high-rise office building, 5 accelerometers) - ENRON Array (power generation facility, 4 acelerometers) - Mihrimah Sultan Mosque Array (450-year-old historical edifice,9 accelerometers + tiltmeters, to be installed in 2009) - Sultanahmet Mosque Array, (390-year-old historical edifice, 9 accelerometers + tiltmeters, to be installed in 2009) • Special Arrays - Atakoy Vertical Array (four 3-component accelerometers at 25, 50, 75, and 150 m depths) - Marmara Tube Tunnel (1400 m long submerged tunnel, 128 ch. accelerometric data, 24 ch. strain data, to be installed in 2010) - Air-Force Academy Array (72 ch. dense accelerometric array to be installed in 2010) - Gemlik Array (a dense basin array of 8 stations, to be installed in 2010) The objectives of these systems and networks are: (1) to produce rapid earthquake intensity, damage and loss assessment information after an earthquake (in the case of IERREWS), (2) to monitor conditions of structural systems, (3) to develop real-time data processing, analysis, and damage detection and location tools (in the case of structural networks) after an extreme event, (4) to assess spatial properties of strong ground motion and ground strain, and to characterise basin response (in the case of special arrays), (5) to investigate site response and wave propagation (in the case of vertical array). Ground motion data obtained from these strong motion networks have and are being used for investigations of attenuation, spatial variation (coherence), simulation benchmarking, source modeling, site response, seismic microzonation, system identification and structural model verification and structural health control. In addition to the systems and networks outlined above there are two temporary networks: KIMNET - a dense urban noise and microtremor network consisting of 50 broadband stations expected to be operational in mid 2009, and SOSEWIN - a 20-station, self-organizing structural integrated array at Ataköy in Istanbul.

  8. Cost minimizing of cutting process for CNC thermal and water-jet machines

    NASA Astrophysics Data System (ADS)

    Tavaeva, Anastasia; Kurennov, Dmitry

    2015-11-01

    This paper deals with optimization problem of cutting process for CNC thermal and water-jet machines. The accuracy of objective function parameters calculation for optimization problem is investigated. This paper shows that working tool path speed is not constant value. One depends on some parameters that are described in this paper. The relations of working tool path speed depending on the numbers of NC programs frames, length of straight cut, configuration part are presented. Based on received results the correction coefficients for working tool speed are defined. Additionally the optimization problem may be solved by using mathematical model. Model takes into account the additional restrictions of thermal cutting (choice of piercing and output tool point, precedence condition, thermal deformations). At the second part of paper the non-standard cutting techniques are considered. Ones may lead to minimizing of cutting cost and time compared with standard cutting techniques. This paper considers the effectiveness of non-standard cutting techniques application. At the end of the paper the future research works are indicated.

  9. Using the Center for Epidemiologic Studies Depression Scale to Screen for Depression in Systemic Lupus Erythematosus

    PubMed Central

    Julian, Laura J.; Gregorich, Steven E.; Tonner, Chris; Yazdany, Jinoos; Trupin, Laura; Criswell, Lindsey A.; Yelin, ED; Katz, Patricia P.

    2013-01-01

    Objective Identifying persons with systemic lupus erythematosus (SLE) at risk for depression would facilitate the identification and treatment of an important comorbidity conferring additional risk for poor outcomes. The purpose of this study was to determine the utility of a brief screening measure, the Center for Epidemiologic Studies Depression Scale (CES-D), in detecting mood disorders in persons with SLE. Methods This cross-sectional study examined 150 persons with SLE. Screening cut points were empirically derived using threshold selection methods, and receiver operating characteristic curves were estimated. The empirically derived cut points of the CES-D were used as the screening measures and were compared to other commonly used CES-D cut points in addition to other commonly used methods to screen for depression. Diagnoses of major depressive disorder or other mood disorders were determined using a “gold standard” structured clinical interview. Results Of the 150 persons with SLE, 26% of subjects met criteria for any mood disorder and 17% met criteria for major depressive disorder. Optimal threshold estimations suggested a CES-D cut score of 24 and above, which yielded adequate sensitivity and specificity in detecting major depressive disorder (88% and 93%, respectively) and correctly classified 92% of participants. To detect the presence of any mood disorder, a cut score of 20 and above was suggested, yielding sensitivity and specificity of 87% and correctly classifying 87%. Conclusion These results suggest the CES-D may be a useful screening measure to identify patients at risk for depression. PMID:21312347

  10. Cutting process simulation of flat drill

    NASA Astrophysics Data System (ADS)

    Tamura, Shoichi; Matsumura, Takashi

    2018-05-01

    Flat drills at a point angle of 180 deg. have recently been developed for drilling of automobile parts with the inclination of the workpiece surfaces. The paper studies the cutting processes of the flat drills in the analytical simulation. A predictive force model is applied to simulation of the cutting force with the chip flow direction. The chip flow model is piled up with orthogonal cuttings in the plane containing the cutting velocities and the chip flow velocities, in which the chip flow direction is determined to minimize the cutting energy. Then, the cutting force is predicted in the determined in the chip flow model. The typical cutting force of the flat drill is discussed with comparing to that of the standard drill. The typical differences are confirmed in the cutting force change during the tool engagement and disengagement. The cutting force, then, is simulated in drilling for an inclined workpiece with a flat drill. The horizontal components in the cutting forces are simulated with changing the inclination angle of the plate. The horizontal force component in the flat drilling is stable to be controlled in terms of the machining accuracy and the tool breakage.

  11. Estimate of serum immunoglobulin G concentration using refractometry with or without caprylic acid fractionation.

    PubMed

    Morrill, K M; Polo, J; Lago, A; Campbell, J; Quigley, J; Tyler, H

    2013-07-01

    Objectives of this study were to develop a rapid calf-side test to determine serum IgG concentrations using caprylic acid (CA) fractionation, followed by refractometry of the IgG-rich supernatant and compare the accuracy of this method with results obtained using refractometry using raw serum. Serum samples (n=200) were obtained from 1-d-old calves, frozen (-20°C), and shipped to the laboratory. Samples were allowed to thaw for 1h at room temperature. Fractionation with CA was conducted by adding 1mL of serum to a tube containing 45, 60, or 75µL of CA and 0.5, 1.0, or 1.5mL of 0.06 M acetic acid. The tube contents were mixed well, allowed to react for 1 min, and then centrifuged at 3,300 × g for 0, 10, or 20 min at 25°C. The %Brix and refractive index of the fractionated supernatant were determined using a digital refractometer. Nonfractionated serum was analyzed for %Brix (BRn), refractive index (nDn), and IgG concentration by radial immunodiffusion. The mean serum IgG concentration was 19.0 mg/mL [standard deviation (SD)=9.7], with a range of 3.5 to 47.0 mg/mL. The mean serum BRn was 8.6 (SD=0.91), with a range of 6.8 to 11.0. The mean serum nDn was 1.34566 (SD=0.00140), with a range of 1.34300 to 1.34930. Serum nDn was positively correlated with IgG concentration (correlation coefficient=0.86; n=185). Fractionated samples treated with 1mL 0.6 M acetic acid and 60µL of CA and not centrifuged before analysis resulted in a strong relationship between the refractive index of the fractionated supernatant and IgG (correlation coefficient=0.80; n=45). Regression was used to determine cut points indicative of 10, 12, and 14 mg of IgG/mL to determine the sensitivity and specificity of refractometry to identify failure of passive transfer (serum IgG <10 mg/mL at 24 h old). The nDn were 1.34414, 1.34448, and 1.34480 to predict 10, 12, and 14 mg of IgG/mL of serum, respectively. The BRn cut points were 7.6, 7.8, and 8.0, respectively. The nDn cut points of 1.34448 and 1.34480 resulted in similar specificities (82.9%), whereas the 1.34414 cut point had a specificity of 60.0%. The BRn cut point of 7.6 and 7.8%Brix resulted in a similar percentage of correctly classified samples (89.7 and 90.8%, respectively); however, the 7.8% Brix cut point resulted in fewer false positives. These results suggest that Brix refractometry of nonfractionated calf serum provides a strong estimate of IgG concentration and 7.8% Brix may be used as the cut point to identify failure of passive transfer in 1-d-old calves. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Airborne ultrasound surface motion camera: Application to seismocardiography

    NASA Astrophysics Data System (ADS)

    Shirkovskiy, P.; Laurin, A.; Jeger-Madiot, N.; Chapelle, D.; Fink, M.; Ing, R. K.

    2018-05-01

    The recent achievements in the accelerometer-based seismocardiography field indicate a strong potential for this technique to address a wide variety of clinical needs. Recordings from different locations on the chest can give a more comprehensive observation and interpretation of wave propagation phenomena than a single-point recording, can validate existing modeling assumptions (such as the representation of the sternum as a single solid body), and provide better identifiability for models using richer recordings. Ultimately, the goal is to advance our physiological understanding of the processes to provide useful data to promote cardiovascular health. Accelerometer-based multichannel system is a contact method and laborious for use in practice, and also even ultralight accelerometers can cause non-negligible loading effects. We propose a contactless ultrasound imaging method to measure thoracic and abdominal surface motions, demonstrating that it is adequate for typical seismocardiogram (SCG) use. The developed method extends non-contact surface-vibrometry to fast 2D mapping by originally combining multi-element airborne ultrasound arrays, a synthetic aperture implementation, and pulsed-waves. Experimental results show the ability of the developed method to obtain 2D seismocardiographic maps of the body surface 30 × 40 cm2 in dimension, with a temporal sampling rate of several hundred Hz, using ultrasound waves with the central frequency of 40 kHz. Our implementation was validated in-vivo on eight healthy human participants. The shape and position of the zone of maximal absolute acceleration and velocity during the cardiac cycle were also observed. This technology could potentially be used to obtain more complete cardio-vascular information than single-source SCG in and out of clinical environments, due to enhanced identifiability provided by the distributed measurements, and observation of propagation phenomena.

  13. Biomechanical analysis of protective countermeasures in underride motor vehicle accidents - biomed 2009.

    PubMed

    Kumar, Sri; Enz, Bruce; Ponder, Perry L; Anderson, Bob

    2009-01-01

    Traffic safety has been significantly improved over the past several decades reducing injury and fatality rates. However, there is a paucity of research effort to address the safety issues in underride accidents, specifically the side underride crashes. It is well known that the compromise of occupant space in the vehicle leads to a higher probability of serious or fatal injuries. A better understanding of occupant protection and mechanism of injuries involved in side underride accidents assists in the advancement of safety measures. The present work evaluates the injury potential to occupants during side underride crashes using the car-to-trailer crash methodology. Four crash tests were conducted into the side of a stationary trailer fitted with the side underride guard system (SURG). The SURG used in these tests is 25% lighter than the previous design. A 5th percentile hybrid III female dummy was placed in the driver seat and restrained with the three-point lap and shoulder harness. The anthropometric dummy was instrumented with a head triaxial accelerometer, a chest triaxal accelerometer, a load cell to measure neck force and moment, and a load cell to measure the femur force. The vehicle acceleration was measured using a traxial accelerometer in the rear center tunnel. High speed, standard video and still photos were taken. In all tests, the intrusion was limited to the front structure of the vehicle without any significant compromise to the occupant space. Results indicate that the resultant head and chest accelerations, head injury criterion (HIC), neck force and moment, and femur force were well below the injury tolerance. The present findings support the hypothesis that the SURG not only limits or eliminates the intrusion into the occupant space but also results in biomechanical injury values well below the tolerance limit in motor vehicle crashes.

  14. Different grades MEMS accelerometers error characteristics

    NASA Astrophysics Data System (ADS)

    Pachwicewicz, M.; Weremczuk, J.

    2017-08-01

    The paper presents calibration effects of two different MEMS accelerometers of different price and quality grades and discusses different accelerometers errors types. The calibration for error determining is provided by reference centrifugal measurements. The design and measurement errors of the centrifuge are discussed as well. It is shown that error characteristics of the sensors are very different and it is not possible to use simple calibration methods presented in the literature in both cases.

  15. Theoretical analysis and concept demonstration of a novel MOEMS accelerometer based on Raman—Nath diffraction

    NASA Astrophysics Data System (ADS)

    Zuwei, Zhang; Zhiyu, Wen; Jing, Hu

    2012-04-01

    The design and simulation of a novel microoptoelectromechanical system (MOEMS) accelerometer based on Raman—Nath diffraction are presented. The device is planned to be fabricated by microelectromechanical system technology and has a different sensing principle than the other reported MOEMS accelerometers. The fundamental theories and principles of the device are discussed in detail, a 3D finite element simulation of the flexural plate wave delay line oscillator is provided, and the operation frequency around 40 MHz is calculated. Finally, a lecture experiment is performed to demonstrate the feasibility of the device. This novel accelerometer is proposed to have the advantages of high sensitivity and anti-radiation, and has great potential for various applications.

  16. Acceleration Recorder and Playback Module

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1996-01-01

    The present invention is directed to methods and apparatus relating to an accelerometer electrical signal recorder and playback module. The recorder module may be manufactured in lightweight configuration and includes analog memory components to store data. Signal conditioning circuitry is incorporated into the module so that signals may be connected directly from the accelerometer to the recorder module. A battery pack may be included for powering both the module and the accelerometer. Timing circuitry is included to control the time duration within which data is recorded or played back so as to avoid overloading the analog memory components. Multiple accelerometer signal recordings may be taken simultaneously without analog to digital circuits, multiplexing circuitry or software to compensate for the effects of multiplexing the signals.

  17. Acceleration recorder and playback module

    NASA Astrophysics Data System (ADS)

    Bozeman, Richard J., Jr.

    1994-11-01

    The present invention is directed to methods and apparatus relating to an accelerometer electrical signal recorder and playback module. The recorder module may be manufactured in lightweight configuration and includes analog memory components to store data. Signal conditioning circuitry is incorporated into the module so that signals may be connected directly from the accelerometer to the recorder module. A battery pack may be included for powering both the module and the accelerometer. Timing circuitry is included to control the time duration within which data is recorded or played back so as to avoid overloading the analog memory components. Multiple accelerometer signal recordings may be taken simultaneously without analog to digital circuits, multiplexing circuitry or software to compensate for the effects of multiplexing the signals.

  18. Acceleration recorder and playback module

    NASA Astrophysics Data System (ADS)

    Bozeman, Richard J., Jr.

    1992-09-01

    The present invention is directed to methods and apparatus relating to an accelerometer electrical signal recorder and playback module. The recorder module may be manufactured in lightweight configuration and includes analog memory components to store data. Signal conditioning circuitry is incorporated into the module so that signals may be connected directly from the accelerometer to the recorder module. A battery pack may be included for powering both the module and the accelerometer. Timing circuitry is included to control the time duration within which data is recorded or played back so as to avoid overloading the analog memory components. Multiple accelerometer signal recordings may be taken simultaneously without analog to digital circuits, multiplexing circuitry or software to compensate for the effects of multiplexing the signals.

  19. Acceleration recorder and playback module

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1994-01-01

    The present invention is directed to methods and apparatus relating to an accelerometer electrical signal recorder and playback module. The recorder module may be manufactured in lightweight configuration and includes analog memory components to store data. Signal conditioning circuitry is incorporated into the module so that signals may be connected directly from the accelerometer to the recorder module. A battery pack may be included for powering both the module and the accelerometer. Timing circuitry is included to control the time duration within which data is recorded or played back so as to avoid overloading the analog memory components. Multiple accelerometer signal recordings may be taken simultaneously without analog to digital circuits, multiplexing circuitry or software to compensate for the effects of multiplexing the signals.

  20. Method and apparatus for measuring the mass flow rate of a fluid

    DOEpatents

    Evans, Robert P.; Wilkins, S. Curtis; Goodrich, Lorenzo D.; Blotter, Jonathan D.

    2002-01-01

    A non invasive method and apparatus is provided to measure the mass flow rate of a multi-phase fluid. An accelerometer is attached to a pipe carrying a multi-phase fluid. Flow related measurements in pipes are sensitive to random velocity fluctuations whose magnitude is proportional to the mean mass flow rate. An analysis of the signal produced by the accelerometer shows a relationship between the mass flow of a fluid and the noise component of the signal of an accelerometer. The noise signal, as defined by the standard deviation of the accelerometer signal allows the method and apparatus of the present invention to non-intrusively measure the mass flow rate of a multi-phase fluid.

  1. Simultaneous processing of photographic and accelerator array data from sled impact experiment

    NASA Astrophysics Data System (ADS)

    Ash, M. E.

    1982-12-01

    A Quaternion-Kalman filter model is derived to simultaneously analyze accelerometer array and photographic data from sled impact experiments. Formulas are given for the quaternion representation of rotations, the propagation of dynamical states and their partial derivatives, the observables and their partial derivatives, and the Kalman filter update of the state given the observables. The observables are accelerometer and tachometer velocity data of the sled relative to the track, linear accelerometer array and photographic data of the subject relative to the sled, and ideal angular accelerometer data. The quaternion constraints enter through perfect constraint observations and normalization after a state update. Lateral and fore-aft impact tests are analyzed with FORTRAN IV software written using the formulas of this report.

  2. Description of the three axis low-g accelerometer package

    NASA Technical Reports Server (NTRS)

    Amalavage, A. J.; Fikes, E. H.; Berry, E. H.

    1978-01-01

    The three axis low-g accelerometer package designed for use on the Space Processing Application Rocket (SPAR) Program is described. The package consists of the following major sections: (1) three Kearfott model 2412 accelerometers mounted in an orthogonal triad configuration on a temperature controlled, thermally isolated cube, (2) the accelerometer servoelectronics (printed circuit cards PC-6 through PC-12), and (3) the signal conditioner (printed circuit cards PC-15 and PC-16). The measurement range is 0 + or - 0.031 g with a quantization of 1.1 x 10 to the 7th power g. The package was flown successfully on six SPAR launches with the Black Brant booster. These flights provide approximately 300 s of free fall or zero-g environment.

  3. Development and validation of cell-based luciferase reporter gene assays for measuring neutralizing anti-drug antibodies against interferon beta.

    PubMed

    Hermanrud, Christina; Ryner, Malin; Luft, Thomas; Jensen, Poul Erik; Ingenhoven, Kathleen; Rat, Dorothea; Deisenhammer, Florian; Sørensen, Per Soelberg; Pallardy, Marc; Sikkema, Dan; Bertotti, Elisa; Kramer, Daniel; Creeke, Paul; Fogdell-Hahn, Anna

    2016-03-01

    Neutralizing anti-drug antibodies (NAbs) against therapeutic interferon beta (IFNβ) in people with multiple sclerosis (MS) are measured with cell-based bioassays. The aim of this study was to redevelop and validate two luciferase reporter-gene bioassays, LUC and iLite, using a cut-point approach to identify NAb positive samples. Such an approach is favored by the pharmaceutical industry and governmental regulatory agencies as it has a clear statistical basis and overcomes the limitations of the current assays based on the Kawade principle. The work was conducted following the latest assay guidelines. The assays were re-developed and validated as part of the "Anti-Biopharmaceutical Immunization: Prediction and analysis of clinical relevance to minimize the risk" (ABIRISK) consortium and involved a joint collaboration between four academic laboratories and two pharmaceutical companies. The LUC assay was validated at Innsbruck Medical University (LUCIMU) and at Rigshospitalet (LUCRH) Copenhagen, and the iLite assay at Karolinska Institutet, Stockholm. For both assays, the optimal serum sample concentration in relation to sensitivity and recovery was 2.5% (v/v) in assay media. A Shapiro-Wilk test indicated a normal distribution for the majority of runs, allowing a parametric approach for cut-point calculation to be used, where NAb positive samples could be identified with 95% confidence. An analysis of means and variances indicated that a floating cut-point should be used for all assays. The assays demonstrated acceptable sensitivity for being cell-based assays, with a confirmed limit of detection in neat serum of 1519 ng/mL for LUCIMU, 814 ng/mL for LUCRH, and 320 ng/mL for iLite. Use of the validated cut-point assay, in comparison with the previously used Kawade method, identified 14% more NAb positive samples. In conclusion, implementation of the cut-point design resulted in increased sensitivity to detect NAbs. However, the clinical significance of these low positive titers needs to be further evaluated. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. The Functional Movement Screen and Injury Risk: Association and Predictive Value in Active Men.

    PubMed

    Bushman, Timothy T; Grier, Tyson L; Canham-Chervak, Michelle; Anderson, Morgan K; North, William J; Jones, Bruce H

    2016-02-01

    The Functional Movement Screen (FMS) is a series of 7 tests used to assess the injury risk in active populations. To determine the association of the FMS with the injury risk, assess predictive values, and identify optimal cut points using 3 injury types. Cohort study; Level of evidence, 2. Physically active male soldiers aged 18 to 57 years (N = 2476) completed the FMS. Demographic and fitness data were collected by survey. Medical record data for overuse injuries, traumatic injuries, and any injury 6 months after the FMS assessment were obtained. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated along with the receiver operating characteristic (ROC) to determine the area under the curve (AUC) and identify optimal cut points for the risk assessment. Risks, risk ratios (RRs), odds ratios (ORs), and 95% CIs were calculated to assess injury risks. Soldiers who scored ≤14 were at a greater risk for injuries compared with those who scored >14 using the composite score for overuse injuries (RR, 1.84; 95% CI, 1.63-2.09), traumatic injuries (RR, 1.26; 95% CI, 1.03-1.54), and any injury (RR, 1.60; 95% CI, 1.45-1.77). When controlling for other known injury risk factors, multivariate logistic regression analysis identified poor FMS performance (OR [score ≤14/19-21], 2.00; 95% CI, 1.42-2.81) as an independent risk factor for injuries. A cut point of ≤14 registered low measures of predictive value for all 3 injury types (sensitivity, 28%-37%; PPV, 19%-52%; AUC, 54%-61%). Shifting the injury risk cut point of ≤14 to the optimal cut points indicated by the ROC did not appreciably improve sensitivity or the PPV. Although poor FMS performance was associated with a higher risk of injuries, it displayed low sensitivity, PPV, and AUC. On the basis of these findings, the use of the FMS to screen for the injury risk is not recommended in this population because of the low predictive value and misclassification of the injury risk. © 2015 The Author(s).

  5. Clinical Diagnostic Utility of IP-10 and LAM Antigen Levels for the Diagnosis of Tuberculous Pleural Effusions in a High Burden Setting

    PubMed Central

    Dheda, Keertan; Van-Zyl Smit, Richard N.; Sechi, Leonardo A.; Badri, Motasim; Meldau, Richard; Symons, Gregory; Khalfey, Hoosein; Carr, Igshaan; Maredza, Alice; Dawson, Rodney; Wainright, Helen; Whitelaw, Andrew; Bateman, Eric D.; Zumla, Alimuddin

    2009-01-01

    Background Current tools for the diagnosis of tuberculosis pleural effusions are sub-optimal. Data about the value of new diagnostic technologies are limited, particularly, in high burden settings. Preliminary case control studies have identified IFN-γ-inducible-10kDa protein (IP-10) as a promising diagnostic marker; however, its diagnostic utility in a day-to-day clinical setting is unclear. Detection of LAM antigen has not previously been evaluated in pleural fluid. Methods We investigated the comparative diagnostic utility of established (adenosine deaminase [ADA]), more recent (standardized nucleic-acid-amplification-test [NAAT]) and newer technologies (a standardized LAM mycobacterial antigen-detection assay and IP-10 levels) for the evaluation of pleural effusions in 78 consecutively recruited South African tuberculosis suspects. All consenting participants underwent pleural biopsy unless contra-indicated or refused. The reference standard comprised culture positivity for M. tuberculosis or histology suggestive of tuberculosis. Principal Findings Of 74 evaluable subjects 48, 7 and 19 had definite, probable and non-TB, respectively. IP-10 levels were significantly higher in TB vs non-TB participants (p<0.0001). The respective outcomes [sensitivity, specificity, PPV, NPV %] for the different diagnostic modalities were: ADA at the 30 IU/L cut-point [96; 69; 90; 85], NAAT [6; 93; 67; 28], IP-10 at the 28,170 pg/ml ROC-derived cut-point [80; 82; 91; 64], and IP-10 at the 4035 pg/ml cut-point [100; 53; 83; 100]. Thus IP-10, using the ROC-derived cut-point, missed ∼20% of TB cases and mis-diagnosed ∼20% of non-TB cases. By contrast, when a lower cut-point was used a negative test excluded TB. The NAAT had a poor sensitivity but high specificity. LAM antigen-detection was not diagnostically useful. Conclusion Although IP-10, like ADA, has sub-optimal specificity, it may be a clinically useful rule-out test for tuberculous pleural effusions. Larger multi-centric studies are now required to confirm our findings. PMID:19277111

  6. Diagnostic accuracy of refractometry for assessing bovine colostrum quality: A systematic review and meta-analysis.

    PubMed

    Buczinski, S; Vandeweerd, J M

    2016-09-01

    Provision of good quality colostrum [i.e., immunoglobulin G (IgG) concentration ≥50g/L] is the first step toward ensuring proper passive transfer of immunity for young calves. Precise quantification of colostrum IgG levels cannot be easily performed on the farm. Assessment of the refractive index using a Brix scale with a refractometer has been described as being highly correlated with IgG concentration in colostrum. The aim of this study was to perform a systematic review of the diagnostic accuracy of Brix refractometry to diagnose good quality colostrum. From 101 references initially obtain ed, 11 were included in the systematic review meta-analysis representing 4,251 colostrum samples. The prevalence of good colostrum samples with IgG ≥50g/L varied from 67.3 to 92.3% (median 77.9%). Specific estimates of accuracy [sensitivity (Se) and specificity (Sp)] were obtained for different reported cut-points using a hierarchical summary receiver operating characteristic curve model. For the cut-point of 22% (n=8 studies), Se=80.2% (95% CI: 71.1-87.0%) and Sp=82.6% (71.4-90.0%). Decreasing the cut-point to 18% increased Se [96.1% (91.8-98.2%)] and decreased Sp [54.5% (26.9-79.6%)]. Modeling the effect of these Brix accuracy estimates using a stochastic simulation and Bayes theorem showed that a positive result with the 22% Brix cut-point can be used to diagnose good quality colostrum (posttest probability of a good colostrum: 94.3% (90.7-96.9%). The posttest probability of good colostrum with a Brix value <18% was only 22.7% (12.3-39.2%). Based on this study, the 2 cut-points could be alternatively used to select good quality colostrum (sample with Brix ≥22%) or to discard poor quality colostrum (sample with Brix <18%). When sample results are between these 2 values, colostrum supplementation should be considered. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. The reliability and validity of the Alcohol Use Disorders Identification Test (AUDIT) in a German general practice population sample.

    PubMed

    Dybek, Inga; Bischof, Gallus; Grothues, Janina; Reinhardt, Susa; Meyer, Christian; Hapke, Ulfert; John, Ulrich; Broocks, Andreas; Hohagen, Fritz; Rumpf, Hans-Jürgen

    2006-05-01

    Our goal was to analyze the retest reliability and validity of the Alcohol Use Disorders Identification Test (AUDIT) in a primary-care setting and recommend a cut-off value for the different alcohol-related diagnoses. Participants recruited from general practices (GPs) in two northern German cities received the AUDIT, which was embedded in a health-risk questionnaire. In total, 10,803 screenings were conducted. The retest reliability was tested on a subsample of 99 patients, with an intertest interval of 30 days. Sensitivity and specificity at a number of different cut-off values were estimated for the sample of alcohol consumers (n=8237). For this study, 1109 screen-positive patients received a diagnostic interview. Individuals who scored less than five points in the AUDIT and also tested negative in a second alcohol-related screen were defined as "negative" (n=6003). This definition was supported by diagnostic interviews of 99 screen-negative patients from which no false negatives could be detected. As the gold standard for detection of an alcohol-use disorder (AUD), we used the Munich-Composite International Diagnostic Interview (MCIDI), which is based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, criteria. On the item level, the reliability, measured by the intraclass correlation coefficient (ICC), ranged between .39 (Item 9) and .98 (Item 10). For the total score, the ICC was .95. For cut-off values of eight points and five points, 87.5% and 88.9%, respectively, of the AUDIT-positives, and 98.9% and 95.1%, respectively, of the AUDIT-negatives were identically identified at retest, with kappa = .86 and kappa = .81. At the cut-off value of five points, we determined good combinations of sensitivity and specificity for the following diagnoses: alcohol dependence (sensitivity and specificity of .97 and .88, respectively), AUD (.97 and .92), and AUD and/or at-risk consumption (.97 and .91). Embedded in a health-risk questionnaire in primary-care settings, the AUDIT is a reliable and valid screening instrument to identify at-risk drinkers and patients with an AUD. Our findings strongly suggest a lowering of the recommended cut-off value of eight points.

  8. Using Performance Measures to Motivate ‘Report-Averse’ and ‘Report-Loving’ Agents

    PubMed Central

    Glazer, Jacob; McGuire, Thomas G.; Newhouse, Joseph P.

    2013-01-01

    In designing a quality report, a health plan needs to account for the report's effect on the doctor, hospital or other provider. This paper proposes a simple model of how quality reporting affects a health care provider, using the example of a doctor subject to reporting with a “cut point” that designates the doctor as above or below some standard. Choice of cut point affects the doctor's welfare through the doctor's preferences about income and by affecting market demand for the doctor's services. These factors lead doctors to be “report-averse” or “report-loving,” a determination that affects a health plan's cost to enlist a doctor in a contract with reporting and that guides choice of a cut point to maximize the doctors' effort to improve her quality. PMID:17996319

  9. Influence of base of support size on arm pointing performance and associated anticipatory postural adjustments.

    PubMed

    Yiou, Eric; Hamaoui, Alain; Le Bozec, Serge

    2007-08-09

    The current study was designed to test the effect of changing the base of support (BoS) size in the initial posture on the performance of a pointing task and the associated "anticipatory postural adjustments" (APAs). Subjects performed series of arm pointing tasks at maximal velocity, from five postures that differed by the antero-posterior (AP) distance between the heels. This distance was increased stepwise from 0 cm (P0 condition) to 40 cm (P40 condition). Kinetics data were collected with a large force-plate, and kinematics data of the pointing were collected with a bi-axial accelerometer (AP and vertical direction) fixed at the wrist. ANOVA showed that the amplitude and the efficiency of the APAs, as well as the performance of the pointing, all statistically increased from P0 to P40 (with 0.0001

  10. Bronchodilator response cut-off points and FEV 0.75 reference values for spirometry in preschoolers

    PubMed Central

    Burity, Edjane Figueiredo; Pereira, Carlos Alberto de Castro; Jones, Marcus Herbert; Sayão, Larissa Bouwman; de Andrade, Armèle Dornelas; de Britto, Murilo Carlos Amorim

    2016-01-01

    ABSTRACT Objective: To determine the cut-off points for FEV1, FEV0.75, FEV0.5, and FEF25-75% bronchodilator responses in healthy preschool children and to generate reference values for FEV0.75. Methods: This was a cross-sectional community-based study involving children 3-5 years of age. Healthy preschool children were selected by a standardized questionnaire. Spirometry was performed before and after bronchodilator use. The cut-off point of the response was defined as the 95th percentile of the change in each parameter. Results: We recruited 266 children, 160 (60%) of whom were able to perform acceptable, reproducible expiratory maneuvers before and after bronchodilator use. The mean age and height were 57.78 ± 7.86 months and 106.56 ± 6.43 cm, respectively. The success rate for FEV0.5 was 35%, 68%, and 70% in the 3-, 4-, and 5-year-olds, respectively. The 95th percentile of the change in the percentage of the predicted value in response to bronchodilator use was 11.6%, 16.0%, 8.5%, and 35.5% for FEV1, FEV0.75, FEV0.5, and FEF25-75%, respectively. Conclusions: Our results provide cut-off points for bronchodilator responsiveness for FEV1, FEV0.75, FEV0.5, and FEF25-75% in healthy preschool children. In addition, we proposed gender-specific reference equations for FEV0.75. Our findings could improve the physiological assessment of respiratory function in preschool children. PMID:27812631

  11. Structural vascular disease in Africans: Performance of ethnic-specific waist circumference cut points using logistic regression and neural network analyses: The SABPA study.

    PubMed

    Botha, J; de Ridder, J H; Potgieter, J C; Steyn, H S; Malan, L

    2013-10-01

    A recently proposed model for waist circumference cut points (RPWC), driven by increased blood pressure, was demonstrated in an African population. We therefore aimed to validate the RPWC by comparing the RPWC and the Joint Statement Consensus (JSC) models via Logistic Regression (LR) and Neural Networks (NN) analyses. Urban African gender groups (N=171) were stratified according to the JSC and RPWC cut point models. Ultrasound carotid intima media thickness (CIMT), blood pressure (BP) and fasting bloods (glucose, high density lipoprotein (HDL) and triglycerides) were obtained in a well-controlled setting. The RPWC male model (LR ROC AUC: 0.71, NN ROC AUC: 0.71) was practically equal to the JSC model (LR ROC AUC: 0.71, NN ROC AUC: 0.69) to predict structural vascular -disease. Similarly, the female RPWC model (LR ROC AUC: 0.84, NN ROC AUC: 0.82) and JSC model (LR ROC AUC: 0.82, NN ROC AUC: 0.81) equally predicted CIMT as surrogate marker for structural vascular disease. Odds ratios supported validity where prediction of CIMT revealed -clinical -significance, well over 1, for both the JSC and RPWC models in African males and females (OR 3.75-13.98). In conclusion, the proposed RPWC model was substantially validated utilizing linear and non-linear analyses. We therefore propose ethnic-specific WC cut points (African males, ≥90 cm; -females, ≥98 cm) to predict a surrogate marker for structural vascular disease. © J. A. Barth Verlag in Georg Thieme Verlag KG Stuttgart · New York.

  12. Aerosol penetration through a model transport system: Comparison of theory and experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McFarland, A.R.; Wong, F.S.; Anand, N.K.

    1991-09-01

    Numerical predictions were made of aerosol penetration through a model transport system. A physical model of the system was constructed and tested in an aerosol wind tunnel to obtain comparative data. The system was 26.6 mm in diameter and consisted of an inlet and three straight sections (oriented horizontally, vertically, and at 45{degree}). Particle sizes covered a range in which losses were primarily caused by inertial and gravitational effects (3-25 {mu}m aerodynamic equivalent diameter (AED)). Tests were conducted at two flow rates (70 and 130 l/min) and two inlet orientations (parallel and perpendicular to the free stream). Wind speed wasmore » 3 m/s for all test cases. The cut points for aerosol penetration through the experimental model vis-a-vis the numerical results are as follows: At a flow rate of 70 l/min with the inlet at 0{degree}, the experimentally observed cut point was 16.2 {mu}m AED while the numerically predicted value was 18.2 {mu}m AED while the numerically predicted value was 18.2 {mu}m AED. At 130 l/min and 0{degree}, the experimental cut point was 12.8 {mu}m AED as compared with a numerically value of 13.7 {mu}m AED. At 70l/min and a 90{degree}, the experimental cut point was 12.0 {mu}m AED while the numerically calculated value was 11.1 {mu}m AED. Slopes of the experimental penetration curves are somewhat steeper than the numerically predicted counterparts.« less

  13. Amyloid positron emission tomography with (18)F-flutemetamol and structural magnetic resonance imaging in the classification of mild cognitive impairment and Alzheimer's disease.

    PubMed

    Duara, Ranjan; Loewenstein, David A; Shen, Qian; Barker, Warren; Potter, Elizabeth; Varon, Daniel; Heurlin, Kristen; Vandenberghe, Rik; Buckley, Christopher

    2013-05-01

    To evaluate the contributions of amyloid-positive (Am+) and medial temporal atrophy-positive (MTA+) scans to the diagnostic classification of prodromal and probable Alzheimer's disease (AD). (18)F-flutemetamol-labeled amyloid positron emission tomography (PET) and magnetic resonance imaging (MRI) were used to classify 10 young normal, 15 elderly normal, 20 amnestic mild cognitive impairment (aMCI), and 27 AD subjects. MTA+ status was determined using a cut point derived from a previous study, and Am+ status was determined using a conservative and liberal cut point. The rates of MRI scans with positive results among young normal, elderly normal, aMCI, and AD subjects were 0%, 20%, 75%, and 82%, respectively. Using conservative cut points, the rates of Am+ scans for these same groups of subjects were 0%, 7%, 50%, and 93%, respectively, with the aMCI group showing the largest discrepancy between Am+ and MTA+ scans. Among aMCI cases, 80% of Am+ subjects were also MTA+, and 70% of amyloid-negative (Am-) subjects were MTA+. The combination of amyloid PET and MTA data was additive, with an overall correct classification rate for aMCI of 86%, when a liberal cut point (standard uptake value ratio = 1.4) was used for amyloid positivity. (18)F-flutemetamol PET and structural MRI provided additive information in the diagnostic classification of aMCI subjects, suggesting an amyloid-independent neurodegenerative component among aMCI subjects in this sample. Copyright © 2013 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  14. Unique environmental effects on physical activity participation: a twin study.

    PubMed

    Duncan, Glen E; Goldberg, Jack; Noonan, Carolyn; Moudon, Anne Vernez; Hurvitz, Philip; Buchwald, Dedra

    2008-04-16

    The health benefits of regular physical activity are well established. However, the relative contribution of heritable and environmental factors to physical activity participation remains controversial. Using a cut-point of 60 minutes of total activity per week, data from the GenomEUtwin project revealed consistent genetic influence on physical activity participation in 37,051 twin pairs from seven countries. We hypothesized that the heritability of physical activity participation would be attenuated using the CDC/ACSM recommended minimum threshold of 150 minutes of moderate intensity activity per week. Data were obtained from 1,389 twin pairs from the community-based University of Washington Twin Registry. Twin similarity in physical activity participation using both cut-points was analyzed using tetrachoric correlations and structural equation modeling in all same-sex pairs. Correlations were higher in monozygotic (r(MZ) = 0.43, 95% CI = 0.33-0.54) than dizygotic pairs (r(DZ) = 0.30, 95% CI = 0.12-0.47) using the 60 minute cut-point. However, differences were attenuated using the 150 minute standard (r(MZ) = 0.30, 95% CI = 0.20-0.40; r(DZ) = 0.25, 95% CI = 0.07-0.42). Using the lower cut-point, the best fitting model of twin resemblance only included additive genetics and unique environment, with a heritability of 45%. In contrast, using the higher threshold, the best fitting model included the common and unique environment, with the unique environment contributing 72% of the variance. Unique environment factors provide the strongest influence on physical activity participation at levels recommended for health benefits.

  15. [Validation of the Montgomery-Åsberg Depression Rating Scale (MADRS) in Colombia].

    PubMed

    Cano, Juan Fernando; Gomez Restrepo, Carlos; Rondón, Martín

    2016-01-01

    To adapt and to validate the Montgomery-Åsberg Depression Rating Scale (MADRS) in Colombia. Observational study for scale validation. Validity criteria were used to determine the severity cut-off points of the tool. Taking into account sensitivity and specificity values, those cut points were contrasted with ICD-10 criteria for depression severity. A a factor analysis was performed. The internal consistencY was determined with the same sample of patients used for the validity criteria. Inter-rater reliability was assessed by evaluating the 22 records of the patients that consented to a video interview. Sensitivity to change was established through a second application of the scale in 28 subjects after a lapse of 14 to 28 days. The study was performed in Bogotá, the tool was applied in 150 patients suffering from major depressive disorder. The cut-off point for moderate depression was 20 (sensitivity, 98%; specificity, 96%), and the cut-off point for severe depression was 34 (sensitivity, 98%; specificity, 92%). The tool appears as a unidimensional scale, which possesses a good internal consistency with (α=.9168). The findings of inter-rater reliability evaluation showed the scale as highly reliable (intraclass correlation coefficient=.9833). The instrument has a good sensitivity to change. The Colombian version of the Montgomery-Åsberg Depression Rating Scale has good psychometric properties and can be used in clinical practice and in clinical research in the field of depressive disorder. Copyright © 2015 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  16. I feel good! Gender differences and reporting heterogeneity in self-assessed health.

    PubMed

    Schneider, Udo; Pfarr, Christian; Schneider, Brit S; Ulrich, Volker

    2012-06-01

    For empirical analysis and policy-oriented recommendations, the precise measurement of individual health or well-being is essential. The difficulty is that the answer may depend on individual reporting behaviour. Moreover, if an individual's health perception varies with certain attitudes of the respondent, reporting heterogeneity may lead to index or cut-point shifts of the health distribution, causing estimation problems. An index shift is a parallel shift in the thresholds of the underlying distribution of health categories. In contrast, a cut-point shift means that the relative position of the thresholds changes, implying different response behaviour. Our paper aims to detect how socioeconomic determinants and health experiences influence the individual valuation of health. We analyse the reporting behaviour of individuals on their self-assessed health status, a five-point categorical variable. Using German panel data, we control for observed heterogeneity in the categorical health variable as well as unobserved individual heterogeneity in the panel estimation. In the empirical analysis, we find strong evidence for cut-point shifts. Our estimation results show different impacts of socioeconomic and health-related variables on the five categories of self-assessed health. Moreover, the answering behaviour varies between female and male respondents, pointing to gender-specific perception and assessment of health. Hence, in case of reporting heterogeneity, using self-assessed measures in empirical studies may be misleading and the information needs to be handled with care.

  17. A longitudinal evaluation of the Center for Epidemiologic Studies-Depression scale (CES-D) in a Rheumatoid Arthritis Population using Rasch Analysis

    PubMed Central

    Covic, Tanya; Pallant, Julie F; Conaghan, Philip G; Tennant, Alan

    2007-01-01

    Background The aim of this study was to test the internal validity of the total Center for Epidemiologic Studies-Depression (CES-D) scale using Rasch analysis in a rheumatoid arthritis (RA) population. Methods CES-D was administered to 157 patients with RA over three time points within a 12 month period. Rasch analysis was applied using RUMM2020 software to assess the overall fit of the model, the response scale used, individual item fit, differential item functioning (DIF) and person separation. Results Pooled data across three time points was shown to fit the Rasch model with removal of seven items from the original 20-item CES-D scale. It was necessary to rescore the response format from four to three categories in order to improve the scale's fit. Two items demonstrated some DIF for age and gender but were retained within the 13-item CES-D scale. A new cut point for depression score of 9 was found to correspond to the original cut point score of 16 in the full CES-D scale. Conclusion This Rasch analysis of the CES-D in a longstanding RA cohort resulted in the construction of a modified 13-item scale with good internal validity. Further validation of the modified scale is recommended particularly in relation to the new cut point for depression. PMID:17629902

  18. Optimal optic nerve sheath diameter threshold for the identification of elevated opening pressure on lumbar puncture in a Chinese population.

    PubMed

    Wang, Lijuan; Feng, Liangshu; Yao, Yan; Wang, Yuzhi; Chen, Ying; Feng, Jiachun; Xing, Yingqi

    2015-01-01

    Ultrasonography of the optic nerve sheath diameter (ONSD) is a non-invasive and rapid method that might be helpful in the identification of increased intracranial pressure (ICP). The use of an ONSD greater than 5 mm on ultrasound as an indicator of increased ICP in a Caucasian population has been studied. However, the cut-off point of this predictor in Chinese patients has not been established. Thus, we conducted this study to identify the ONSD criterion for the detection of elevated opening pressure on lumbar puncture (LP) in a Chinese population and to investigate the influencing factors. This study was a blind cross-sectional study. Patients who presented with suspected increased ICP were included. The opening pressure on LP of each participant was confirmed. We analyzed the clinical differences between the groups of patients with abnormal and normal opening pressures on LP. A receiver operating characteristic curve was constructed to determine the ONSD cut-off point for the identification of abnormal opening pressure on LP. In total, 279 patients were recruited, and 101 patients presented with elevated opening pressure on LP. ONSD was a significant independent predictor of elevated opening pressure on LP (p<0.001). However, no statistical significance was observed regarding the factors that might have affected this relationship including gender, age, body mass index, waistline, head circumference, hypertension and pathological subtype. The ONSD cut-off point for the identification of elevated opening pressure on LP was 4.1 mm; this cut-off yielded a sensitivity of 95% and a specificity of 92%. ONSD is a strong and accurate predictor of elevated opening pressure on LP. The cut-off point of this predictor in a Chinese population was remarkably lower than that found in a Caucasian population. Thus, ethnic differences should be noted when using the ONSD as an indicator of increased ICP.

  19. Experimental characterization of turbulent inflow noise on a full-scale wind turbine

    NASA Astrophysics Data System (ADS)

    Buck, Steven; Oerlemans, Stefan; Palo, Scott

    2016-12-01

    An extensive experimental campaign was conducted on a 108-m diameter 2.3-MW wind turbine in order to assess the effect of inflow turbulence conditions on wind turbine acoustics. Over 50 h of continuous acoustic data was acquired at power-generating wind speeds. Twelve precision microphones were used, arranged in a one rotor radius ring about the turbine tower in order to assess the directivity of the noise emission. Turbine operational and atmospheric conditions were gathered simultaneously with acoustics measurements. The testing and analysis constitute perhaps the most thorough experimental characterization of turbulent inflow noise from a wind turbine to date. Turbulence intensities typically varied between 10 percent and 35 percent, and wind speeds covered most of the operational range of the wind turbine, from cut-on to well above its rated power. A method was developed for using blade-mounted accelerometers for determining the turbulence conditions in the immediate vicinity of the blades, which are the primary turbulence noise generating bodies. The method uses the blades' vibrational energy within a specified frequency range to estimate the overall turbulence conditions by assuming a von Kármán turbulence spectrum. Using this method, a clear positive correlation is shown between turbulence intensity and noise levels. The turbulence noise is dominant at low frequencies and is primarily observed in the upwind and downwind directions. Low frequency noise increases by as much as 6 dB for the range of turbulence conditions measured. Comparisons are made between the measured turbine noise directivity and theory using a simple acoustic model of the turbine as three point-sources. Strong agreement is found between the theoretical leading edge noise directivity model and the measured low frequency noise directivity.

  20. Compensation of Physical Activity and Sedentary Time in Primary School Children

    PubMed Central

    RIDGERS, NICOLA D.; TIMPERIO, ANNA; CERIN, ESTER; SALMON, JO

    2014-01-01

    ABSTRACT Purpose There is considerable debate about the possibility of physical activity compensation. This study examined whether increased levels in physical activity and/or sedentary behavior on 1 d were predictive of lower levels in these behaviors on the following day (compensatory mechanisms) among children. Methods Two hundred and forty-eight children (121 boys and 127 girls) age 8–11 yr from nine primary schools in Melbourne, Australia, wore a GT3X+ ActiGraph for seven consecutive days. Time spent in light physical activity (LPA) and moderate- to vigorous-intensity physical activity (MVPA) was derived using age-specific cut points. Sedentary time was defined as 100 counts per minute. Meteorological data (temperature, precipitation, relative humidity, and daylight hours) were obtained daily and matched to accelerometer wear days. Multilevel analyses (day, child, and school) were conducted using generalized linear latent and mixed models. Results On any given day, every additional 10 min spent in MVPA was associated with approximately 25 min less LPA and 5 min less MVPA the following day. Similarly, additional time spent in LPA on any given day was associated with less time in LPA and MVPA the next day. Time spent sedentary was associated with less sedentary time the following day. Adjusting for meteorological variables did not change observed compensation effects. No significant moderating effect of sex was observed. Conclusion The results are consistent with the compensation hypothesis, whereby children appear to compensate their physical activity or sedentary time between days. Additional adjustment for meteorological variables did not change the observed associations. Further research is needed to examine what factors may explain apparent compensatory changes in children’s physical activity and sedentary time. PMID:24492632

Top