Hoscheit, Larry P; Heng, Hock Gan; Lim, Chee Kin; Weng, Hsin-Yi
2018-05-01
Image quality in B-mode ultrasound is important as it reflects the diagnostic accuracy and diagnostic information provided during clinical scanning. Quality assurance programs for B-mode ultrasound systems/components are comprised of initial quality acceptance testing and subsequent regularly scheduled quality control testing. The importance of quality assurance programs for B-mode ultrasound image quality using ultrasound phantoms is well documented in the human medical and medical physics literature. The purpose of this prospective, cross-sectional, survey study was to determine the prevalence and methodology of quality acceptance testing and quality control testing of image quality for ultrasound system/components among veterinary sonographers. An online electronic survey was sent to 1497 members of veterinary imaging organizations: the American College of Veterinary Radiology, the Veterinary Ultrasound Society, and the European Association of Veterinary Diagnostic Imaging, and a total of 167 responses were received. The results showed that the percentages of veterinary sonographers performing quality acceptance testing and quality control testing are 42% (64/151; 95% confidence interval 34-52%) and 26% (40/156: 95% confidence interval 19-33%) respectively. Of the respondents who claimed to have quality acceptance testing or quality control testing of image quality in place for their ultrasound system/components, 0% have performed quality acceptance testing or quality control testing correctly (quality acceptance testing 95% confidence interval: 0-6%, quality control testing 95% confidence interval: 0-11%). Further education and guidelines are recommended for veterinary sonographers in the area of quality acceptance testing and quality control testing for B-mode ultrasound equipment/components. © 2018 American College of Veterinary Radiology.
Chan, Amy Hai Yan; Stewart, Alistair William; Harrison, Jeff; Black, Peter Nigel; Mitchell, Edwin Arthur; Foster, Juliet Michelle
2017-05-01
To investigate the performance and patient acceptability of an inhaler electronic monitoring device in a real-world childhood asthma population. Children 6 to 15 years presenting with asthma to the hospital emergency department and prescribed inhaled corticosteroids were included. Participants were randomized to receive a device with reminder features enabled or disabled for use with their preventer. Device quality control tests were conducted. Questionnaires on device acceptability, utility and ergonomics were completed at six months. A total of 1306 quality control tests were conducted; 84% passed pre-issue and 87% return testing. The most common failure reason was actuation under-recording. Acceptability scores were high, with higher scores in the reminder than non-reminder group (median, 5 th -95 th percentile: 4.1, 3.1-5.0 versus 3.7, 2.3-4.8; p < 0.001). Most (>90%) rated the device easy to use. Feedback was positive across five themes: device acceptability, ringtone acceptability, suggestions for improvement, effect on medication use, and effect on asthma control. This study investigates electronic monitoring device performance and acceptability in children using quantitative and qualitative measures. Results indicate satisfactory reliability, although failure rates of 13-16% indicate the importance of quality control. Favorable acceptability ratings support the use of these devices in children.
Yan, Binjun; Li, Yao; Guo, Zhengtai; Qu, Haibin
2014-01-01
The concept of quality by design (QbD) has been widely accepted and applied in the pharmaceutical manufacturing industry. There are still two key issues to be addressed in the implementation of QbD for herbal drugs. The first issue is the quality variation of herbal raw materials and the second issue is the difficulty in defining the acceptable ranges of critical quality attributes (CQAs). To propose a feedforward control strategy and a method for defining the acceptable ranges of CQAs for the two issues. In the case study of the ethanol precipitation process of Danshen (Radix Salvia miltiorrhiza) injection, regression models linking input material attributes and process parameters to CQAs were built first and an optimisation model for calculating the best process parameters according to the input materials was established. Then, the feasible material space was defined and the acceptable ranges of CQAs for the previous process were determined. In the case study, satisfactory regression models were built with cross-validated regression coefficients (Q(2) ) all above 91 %. The feedforward control strategy was applied successfully to compensate the quality variation of the input materials, which was able to control the CQAs in the 90-110 % ranges of the desired values. In addition, the feasible material space for the ethanol precipitation process was built successfully, which showed the acceptable ranges of the CQAs for the concentration process. The proposed methodology can help to promote the implementation of QbD for herbal drugs. Copyright © 2013 John Wiley & Sons, Ltd.
Quality Assurance of Chemical Measurements.
ERIC Educational Resources Information Center
Taylor, John K.
1981-01-01
Reviews aspects of quality control (methods to control errors) and quality assessment (verification that systems are operating within acceptable limits) including an analytical measurement system, quality control by inspection, control charts, systematic errors, and use of SRMs, materials for which properties are certified by the National Bureau…
Nitrosi, Andrea; Bertolini, Marco; Borasi, Giovanni; Botti, Andrea; Barani, Adriana; Rivetti, Stefano; Pierotti, Luisa
2009-12-01
Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance.
Hot mix asphalt voids acceptance review of QC/QA data 2000 through 2004.
DOT National Transportation Integrated Search
2006-07-01
This report analyzes the Quality Control/Quality Assurance (QC/QA) data for hot mix asphalt using voids acceptance as : the testing criteria for the years 2000 through 2004. Analysis of the overall quality of the HMA is accomplished by : reviewing th...
14 CFR 145.211 - Quality control system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...
14 CFR 145.211 - Quality control system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...
46 CFR 164.120-11 - Production quality control requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 6 2014-10-01 2014-10-01 false Production quality control requirements. 164.120-11... Rescue Boats § 164.120-11 Production quality control requirements. The resin manufacturer must institute a quality control procedure to ensure that all Coast Guard-accepted resin is produced to the same...
46 CFR 164.120-11 - Production quality control requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 6 2012-10-01 2012-10-01 false Production quality control requirements. 164.120-11... Rescue Boats § 164.120-11 Production quality control requirements. The resin manufacturer must institute a quality control procedure to ensure that all Coast Guard-accepted resin is produced to the same...
46 CFR 164.120-11 - Production quality control requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 6 2013-10-01 2013-10-01 false Production quality control requirements. 164.120-11... Rescue Boats § 164.120-11 Production quality control requirements. The resin manufacturer must institute a quality control procedure to ensure that all Coast Guard-accepted resin is produced to the same...
7 CFR 58.141 - Alternate quality control program.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by the...
Quality-control issues on high-resolution diagnostic monitors.
Parr, L F; Anderson, A L; Glennon, B K; Fetherston, P
2001-06-01
Previous literature indicates a need for more data collection in the area of quality control of high-resolution diagnostic monitors. Throughout acceptance testing, which began in June 2000, stability of monitor calibration was analyzed. Although image quality on all monitors was found to be acceptable upon initial acceptance testing using VeriLUM software by Image Smiths, Inc (Germantown, MD), it was determined to be unacceptable during the clinical phase of acceptance testing. High-resolution monitors were evaluated for quality assurance on a weekly basis from installation through acceptance testing and beyond. During clinical utilization determination (CUD), monitor calibration was identified as a problem and the manufacturer returned and recalibrated all workstations. From that time through final acceptance testing, high-resolution monitor calibration and monitor failure rate remained a problem. The monitor vendor then returned to the site to address these areas. Monitor defocus was still noticeable and calibration checks were increased to three times per week. White and black level drift on medium-resolution monitors had been attributed to raster size settings. Measurements of white and black level at several different size settings were taken to determine the effect of size on white and black level settings. Black level remained steady with size change. White level appeared to increase by 2.0 cd/m2 for every 0.1 inches decrease in horizontal raster size. This was determined not to be the cause of the observed brightness drift. Frequency of calibration/testing is an issue in a clinical environment. The increased frequency required at our site cannot be sustained. The medical physics division cannot provide dedicated personnel to conduct the quality-assurance testing on all monitors at this interval due to other physics commitments throughout the hospital. Monitor access is also an issue due to radiologists' need to read images. Some workstations are in use 7 AM to 11 PM daily. An appropriate monitor calibration frequency must be established during acceptance testing to ensure unacceptable drift is not masked by excessive calibration frequency. Standards for acceptable black level and white level drift also need to be determined. The monitor vendor and hospital staff agree that currently, very small printed text is an acceptable method of determining monitor blur, however, a better method of determining monitor blur is being pursued. Although monitors may show acceptable quality during initial acceptance testing, they need to show sustained quality during the clinical acceptance-testing phase. Defocus, black level, and white level are image quality concerns, which need to be evaluated during the clinical phase of acceptance testing. Image quality deficiencies can have a negative impact on patient care and raise serious medical-legal concerns. The attention to quality control required of the hospital staff needs to be realistic and not have a significant impact on radiology workflow.
7 CFR 58.149 - Alternate quality control programs for dairy products.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Alternate quality control programs for dairy products... and Grading Service 1 Operations and Operating Procedures § 58.149 Alternate quality control programs for dairy products. (a) When a plant has in operation an acceptable quality control program which is...
Khan, Imran; Yousif, Adel M; Johnson, Stuart K; Gamlath, Shirani
2014-08-01
Whole grain sorghum is a valuable source of resistant starch and polyphenolic antioxidants and its addition into staple food like pasta may reduce the starch digestibility. However, incorporating nondurum wheat materials into pasta provides a challenge in terms of maintaining cooking quality and consumer acceptability. Pasta was prepared from 100% durum wheat semolina (DWS) as control or by replacing DWS with either wholegrain red sorghum flour (RSF) or white sorghum flour (WSF) each at 20%, 30%, and 40% incorporation levels, following a laboratory-scale procedure. Pasta samples were evaluated for proximate composition, in vitro starch digestibility, cooking quality, and consumer acceptability. The addition of both RSF and WSF lowered the extent of in vitro starch digestion at all substitution levels compared to the control pasta. The rapidly digestible starch was lowered in all the sorghum-containing pastas compared to the control pasta. Neither RSF or WSF addition affected the pasta quality attributes (water absorption, swelling index, dry matter, adhesiveness, cohesiveness, and springiness), except color and hardness which were negatively affected. Consumer sensory results indicated that pasta samples containing 20% and 30% RSF or WSF had acceptable palatability based on meeting one or both of the preset acceptability criteria. It is concluded that the addition of wholegrain sorghum flour to pasta at 30% incorporation level is possible to reduce starch digestibility, while maintaining adequate cooking quality and consumer acceptability. © 2014 Institute of Food Technologists®
48 CFR 246.407 - Nonconforming supplies or services.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SYSTEM, DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT QUALITY ASSURANCE Government Contract Quality Assurance... the material, or perform the service, at no cost to the Government; and (iii) May accept consideration... design control activity is the approval authority for acceptance of any nonconforming aviation or ship...
Hot mix asphalt voids acceptance review of QC/QA data 2000 through 2010.
DOT National Transportation Integrated Search
2011-10-01
This report analyzes the quality control/quality assurance (QC/QA) data for hot mix asphalt (HMA) using : voids acceptance as the testing criteria awarded in the years 2000 through 2010. Analysis of the overall : performance of the projects is accomp...
An engineering approach to controlling indoor air quality.
Woods, J E
1991-11-01
Evidence is accumulating that indicates air quality problems in residential and commercial buildings are nearly always associated with inadequacies in building design and methods of operation. Thus, the very systems depended on to control the indoor environment can become indirect sources of contamination if diligence is not exercised at each stage of a building's life: a) planning and design, b) construction and commissioning, c) operation, and d) demolition or renovation. In this paper, an engineering perspective is presented in which the existing building stock is characterized in terms of its environmental performance. Preliminary data indicate that 20 to 30% of the existing buildings have sufficient problems to manifest as sick-building syndrome or building-related illness, while another 10 to 20% may have undetected problems. Thus, only about 50 to 70% of the existing buildings qualify as healthy buildings. Two methods and three mechanisms of control are described to achieve "acceptable" indoor air quality: source control and exposure control. If sources cannot be removed, some level of occupant exposure will result. To control exposures with acceptable values, the primary sensory receptors of the occupants (i.e., thermal, ocular, auditory, and olfactory) cannot be excessively stimulated. The three exposure control mechanisms are conduction, radiation, and convection. To achieve acceptable occupant responses, it is often practical to integrate the mechanisms of radiation and convection in heating, ventilating, and air conditioning systems that are designed to provide acceptable thermal, acoustic, and air quality conditions within occupied spaces.(ABSTRACT TRUNCATED AT 250 WORDS)
An engineering approach to controlling indoor air quality.
Woods, J E
1991-01-01
Evidence is accumulating that indicates air quality problems in residential and commercial buildings are nearly always associated with inadequacies in building design and methods of operation. Thus, the very systems depended on to control the indoor environment can become indirect sources of contamination if diligence is not exercised at each stage of a building's life: a) planning and design, b) construction and commissioning, c) operation, and d) demolition or renovation. In this paper, an engineering perspective is presented in which the existing building stock is characterized in terms of its environmental performance. Preliminary data indicate that 20 to 30% of the existing buildings have sufficient problems to manifest as sick-building syndrome or building-related illness, while another 10 to 20% may have undetected problems. Thus, only about 50 to 70% of the existing buildings qualify as healthy buildings. Two methods and three mechanisms of control are described to achieve "acceptable" indoor air quality: source control and exposure control. If sources cannot be removed, some level of occupant exposure will result. To control exposures with acceptable values, the primary sensory receptors of the occupants (i.e., thermal, ocular, auditory, and olfactory) cannot be excessively stimulated. The three exposure control mechanisms are conduction, radiation, and convection. To achieve acceptable occupant responses, it is often practical to integrate the mechanisms of radiation and convection in heating, ventilating, and air conditioning systems that are designed to provide acceptable thermal, acoustic, and air quality conditions within occupied spaces.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1821369
DOT National Transportation Integrated Search
2015-01-01
Acceptance of earthwork construction by the Florida Department of Transportation (FDOT) : requires in-place testing conducted with a nuclear density gauge (NDG) to determine : dry density, which must obtain a required percent compaction based upon a ...
48 CFR 46.105 - Contractor responsibilities.
Code of Federal Regulations, 2014 CFR
2014-10-01
... CONTRACT MANAGEMENT QUALITY ASSURANCE General 46.105 Contractor responsibilities. (a) The contractor is responsible for carrying out its obligations under the contract by— (1) Controlling the quality of supplies or..., subassemblies, etc., have an acceptable quality control system; and (4) Maintaining substantiating evidence...
48 CFR 46.105 - Contractor responsibilities.
Code of Federal Regulations, 2012 CFR
2012-10-01
... CONTRACT MANAGEMENT QUALITY ASSURANCE General 46.105 Contractor responsibilities. (a) The contractor is responsible for carrying out its obligations under the contract by— (1) Controlling the quality of supplies or..., subassemblies, etc., have an acceptable quality control system; and (4) Maintaining substantiating evidence...
48 CFR 46.105 - Contractor responsibilities.
Code of Federal Regulations, 2011 CFR
2011-10-01
... CONTRACT MANAGEMENT QUALITY ASSURANCE General 46.105 Contractor responsibilities. (a) The contractor is responsible for carrying out its obligations under the contract by— (1) Controlling the quality of supplies or..., subassemblies, etc., have an acceptable quality control system; and (4) Maintaining substantiating evidence...
48 CFR 46.105 - Contractor responsibilities.
Code of Federal Regulations, 2013 CFR
2013-10-01
... CONTRACT MANAGEMENT QUALITY ASSURANCE General 46.105 Contractor responsibilities. (a) The contractor is responsible for carrying out its obligations under the contract by— (1) Controlling the quality of supplies or..., subassemblies, etc., have an acceptable quality control system; and (4) Maintaining substantiating evidence...
Quality Assurance and Quality Control Practices for Rehabilitation of Sewer and Water Mains
As part of the US Environmental Protection Agency (EPA)’s Aging Water Infrastructure Research Program, several areas of research are being pursued, including a review of quality assurance and quality control (QA/QC) practices and acceptance testing during the installation of reha...
Quality Assurance and Quality Control Practices For Rehabilitation of Sewer and Water Mains
As part of the US Environmental Protection Agency (EPA)’s Aging Water Infrastructure Research Program, several areas of research are being pursued including a review of quality assurance and quality control (QA/QC) practices and acceptance testing during the installation of rehab...
DOT National Transportation Integrated Search
2013-11-01
Current roadway quality control and quality acceptance (QC/QA) procedures for the Louisiana Department of Transportation and : Development (LADOTD) include coring for thickness, density, and air voids in hot mix asphalt (HMA) pavements and thickness ...
Assuring Quality in Education Evaluation.
ERIC Educational Resources Information Center
Trochim, William M. K.; Visco, Ronald J.
1986-01-01
A number of quality assurance educational evaluation methods are illustrated. Evaluation data obtained from the Providence, Rhode Island, school district are used. The methods are: (1) from auditing, internal control; (2) from accounting, double bookkeeping; and (3) from industrial quality control, acceptance sampling and cumulative percentage…
Artificial Intelligence Approach to Support Statistical Quality Control Teaching
ERIC Educational Resources Information Center
Reis, Marcelo Menezes; Paladini, Edson Pacheco; Khator, Suresh; Sommer, Willy Arno
2006-01-01
Statistical quality control--SQC (consisting of Statistical Process Control, Process Capability Studies, Acceptance Sampling and Design of Experiments) is a very important tool to obtain, maintain and improve the Quality level of goods and services produced by an organization. Despite its importance, and the fact that it is taught in technical and…
SB certification for mixture-based specification for flexible base.
DOT National Transportation Integrated Search
2012-10-01
Presentation topics: : Establish List of Qualified Producers; : Producers Responsible for Process Control/Quality Control; : Reduce TxDOT Sampling and Testing; : Expedite Aggregate Base Acceptance; : Share Responsibility (Producer/TxDOT) for Quality ...
DOT National Transportation Integrated Search
2013-11-01
Current roadway quality control and quality acceptance (QC/QA) procedures for the Louisiana Department of Transportation and Development : (LADOTD) include coring for thickness, density, and air voids in hot mix asphalt (HMA) pavements and thickness ...
Veehof, M M; Trompetter, H R; Bohlmeijer, E T; Schreurs, K M G
2016-01-01
The number of acceptance- and mindfulness-based interventions for chronic pain, such as acceptance and commitment therapy (ACT), mindfulness-based stress reduction (MBSR), and mindfulness-based cognitive therapy (MBCT), increased in recent years. Therefore an update is warranted of our former systematic review and meta-analysis of studies that reported effects on the mental and physical health of chronic pain patients. Pubmed, EMBASE, PsycInfo and Cochrane were searched for eligible studies. Current meta-analysis only included randomized controlled trials (RCTs). Studies were rated for quality. Mean quality did not improve in recent years. Pooled standardized mean differences using the random-effect model were calculated to represent the average intervention effect and, to perform subgroup analyses. Outcome measures were pain intensity, depression, anxiety, pain interference, disability and quality of life. Included were twenty-five RCTs totaling 1285 patients with chronic pain, in which we compared acceptance- and mindfulness-based interventions to the waitlist, (medical) treatment-as-usual, and education or support control groups. Effect sizes ranged from small (on all outcome measures except anxiety and pain interference) to moderate (on anxiety and pain interference) at post-treatment and from small (on pain intensity and disability) to large (on pain interference) at follow-up. ACT showed significantly higher effects on depression and anxiety than MBSR and MBCT. Studies' quality, attrition rate, type of pain and control group, did not moderate the effects of acceptance- and mindfulness-based interventions. Current acceptance- and mindfulness-based interventions, while not superior to traditional cognitive behavioral treatments, can be good alternatives.
Numerical simulation of intelligent compaction technology for construction quality control.
DOT National Transportation Integrated Search
2014-12-01
Intelligent compaction (IC) technique is a fast-developing technology for compaction quality control and acceptance. Proof rolling using the intelligent compaction rollers after completing compaction can eectively identify : the weak spots and sig...
DOT National Transportation Integrated Search
2009-07-01
Current roadway quality control and quality acceptance (QC/QA) procedures : for Louisiana include coring for thickness, density, and air void checks in hot : mix asphalt (HMA) pavements and thickness and compressive strength for : Portland cement con...
Quality Leadership and Quality Control
Badrick, Tony
2003-01-01
Different quality control rules detect different analytical errors with varying levels of efficiency depending on the type of error present, its prevalence and the number of observations. The efficiency of a rule can be gauged by inspection of a power function graph. Control rules are only part of a process and not an end in itself; just as important are the trouble-shooting systems employed when a failure occurs. 'Average of patient normals' may develop as a usual adjunct to conventional quality control serum based programmes. Acceptable error can be based on various criteria; biological variation is probably the most sensible. Once determined, acceptable error can be used as limits in quality control rule systems. A key aspect of an organisation is leadership, which links the various components of the quality system. Leadership is difficult to characterise but its key aspects include trust, setting an example, developing staff and critically setting the vision for the organisation. Organisations also have internal characteristics such as the degree of formalisation, centralisation, and complexity. Medical organisations can have internal tensions because of the dichotomy between the bureaucratic and the shadow medical structures. PMID:18568046
23 CFR 637.207 - Quality assurance program.
Code of Federal Regulations, 2011 CFR
2011-04-01
... independent assurance (IA) program consisting of the following: (1) Acceptance program. (i) Each STD's... quality control samples. (C) The quality control sampling and testing is evaluated by an IA program. (iii... appropriate. See 23 CFR 635.413(e) for specific requirements. (2) The IA program shall evaluate the qualified...
Material quality assurance risk assessment : [summary].
DOT National Transportation Integrated Search
2013-01-01
With the shift from quality control (QC) of materials and placement techniques : to quality assurance (QA) and acceptance over the years, the role of the Office : of Materials Technology (OMT) has been shifting towards assurance of : material quality...
Acceptance Probability (P a) Analysis for Process Validation Lifecycle Stages.
Alsmeyer, Daniel; Pazhayattil, Ajay; Chen, Shu; Munaretto, Francesco; Hye, Maksuda; Sanghvi, Pradeep
2016-04-01
This paper introduces an innovative statistical approach towards understanding how variation impacts the acceptance criteria of quality attributes. Because of more complex stage-wise acceptance criteria, traditional process capability measures are inadequate for general application in the pharmaceutical industry. The probability of acceptance concept provides a clear measure, derived from specific acceptance criteria for each quality attribute. In line with the 2011 FDA Guidance, this approach systematically evaluates data and scientifically establishes evidence that a process is capable of consistently delivering quality product. The probability of acceptance provides a direct and readily understandable indication of product risk. As with traditional capability indices, the acceptance probability approach assumes that underlying data distributions are normal. The computational solutions for dosage uniformity and dissolution acceptance criteria are readily applicable. For dosage uniformity, the expected AV range may be determined using the s lo and s hi values along with the worst case estimates of the mean. This approach permits a risk-based assessment of future batch performance of the critical quality attributes. The concept is also readily applicable to sterile/non sterile liquid dose products. Quality attributes such as deliverable volume and assay per spray have stage-wise acceptance that can be converted into an acceptance probability. Accepted statistical guidelines indicate processes with C pk > 1.33 as performing well within statistical control and those with C pk < 1.0 as "incapable" (1). A C pk > 1.33 is associated with a centered process that will statistically produce less than 63 defective units per million. This is equivalent to an acceptance probability of >99.99%.
21 CFR 211.165 - Testing and release for distribution.
Code of Federal Regulations, 2010 CFR
2010-04-01
... products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release. The statistical quality control criteria shall include appropriate acceptance levels and/or appropriate rejection levels. (e) The accuracy, sensitivity, specificity, and...
Material quality assurance risk assessment.
DOT National Transportation Integrated Search
2013-01-01
Over the past two decades the role of SHA has shifted from quality control (QC) of materials and : placement techniques to quality assurance (QA) and acceptance. The role of the Office of Materials : Technology (OMT) has been shifting towards assuran...
Total Quality Management: Getting Started
1990-08-01
Quality Management (TQM) program using Organizational Development (OD) intervention techniques to gain acceptance of the program. It emphasizes human behavior and the need for collaborative management and consensus in organizational change. Lessons learned stress the importance of choosing a skilled TQM facilitator, training process action teams, and fostering open communication and teamwork to minimize resistance to change. Keywords: Management planning and control, Quality control, Quality , Management , Organization change, Organization development,
ERIC Educational Resources Information Center
Haapakorpi, Arja; Geirsdóttir, Guðrún; Jóhannsdóttir, Gyða
2013-01-01
With quality assurance related to the Bologna goals, universities are required to fulfil internationally accepted standardized criteria of quality. This tends to reinforce control in assessment. However, control-oriented evaluations seem to lack meaning for academic staff. The article explored the possibilities and space for improvement-oriented…
Khouryieh, H; Aramouni, F
2013-12-01
Extensive research has revealed numerous nutritional and health benefits of flaxseed due primarily to its nutrients content. The objective of this study was to evaluate the effect of flaxseed flour addition on the physical and sensory characteristics of cereal bars. Four formulations of the flaxseed cereal bars were prepared by partially replacing oats with flaxseed flour added at levels of 0 (control), 6%, 12% and 18%. There were no significant differences (p > 0.05) in water activity, moisture and firmness values between the flaxseed bars and control. Flaxseed addition significantly (p < 0.05) decreased lightness and increased redness of the bars. There were no significant differences (p > 0.05) between the 12% flax cereal bars and the control with respect to sensory attributes and overall acceptability. The overall acceptability for both 12% flax bars and the control was in between 'like moderately' and 'like slightly' on the 9-point hedonic scale. The overall acceptability was most highly correlated with flavor acceptability for both control (r = 0.80) and 12% flax (r = 0.82) cereal bars. Flaxseed bars provided 12% dietary fiber of the daily recommended value. These results indicated that flaxseed flour incorporation up to 12% substantially enhanced the nutritional qualities of the cereal bars without affecting their sensory and quality properties.
Parametric synthesis of a robust controller on a base of mathematical programming method
NASA Astrophysics Data System (ADS)
Khozhaev, I. V.; Gayvoronskiy, S. A.; Ezangina, T. A.
2018-05-01
Considered paper is dedicated to deriving sufficient conditions, linking root indices of robust control quality with coefficients of interval characteristic polynomial, on the base of mathematical programming method. On the base of these conditions, a method of PI- and PID-controllers, providing aperiodic transient process with acceptable stability degree and, subsequently, acceptable setting time, synthesis was developed. The method was applied to a problem of synthesizing a controller for a depth control system of an unmanned underwater vehicle.
Food Fortification Stability Study
NASA Technical Reports Server (NTRS)
Sirmons, T. A.; Cooper, M. R.; Douglas, G. L.
2016-01-01
This study aims to assess the stability of vitamin content, sensory acceptability and color variation in fortified spaceflight foods over a period of 2 years. Findings will identify optimal formulation, processing, and storage conditions to maintain stability and acceptability of commercially available fortification nutrients. Changes in food quality are being monitored to indicate whether fortification affects quality over time (compared to the unfortified control), thus indicating their potential for use on long-duration missions.
Food Fortification Stability Study
NASA Technical Reports Server (NTRS)
Sirmons, T. A.; Cooper, M. R.; Douglas, G. L.
2017-01-01
This study aimed to assess the stability of vitamin content, sensory acceptability and color variation in fortified spaceflight foods over a period of two years. Findings will help to identify optimal formulation, processing, and storage conditions to maintain stability and acceptability of commercially available fortification nutrients. Changes in food quality were monitored to indicate whether fortification affects quality over time (compared to the unfortified control), thus indicating their potential for use on long-duration missions.
V/STOLAND avionics system flight-test data on a UH-1H helicopter
NASA Technical Reports Server (NTRS)
Baker, F. A.; Jaynes, D. N.; Corliss, L. D.; Liden, S.; Merrick, R. B.; Dugan, D. C.
1980-01-01
The flight-acceptance test results obtained during the acceptance tests of the V/STOLAND (versatile simplex digital avionics system) digital avionics system on a Bell UH-1H helicopter in 1977 at Ames Research Center are presented. The system provides navigation, guidance, control, and display functions for NASA terminal area VTOL research programs and for the Army handling qualities research programs at Ames Research Center. The acceptance test verified system performance and contractual acceptability. The V/STOLAND hardware navigation, guidance, and control laws resident in the digital computers are described. Typical flight-test data are shown and discussed as documentation of the system performance at acceptance from the contractor.
Wilks, Robert S.; Sturges, Jr., Robert H.
1983-01-01
The invention provides a method of and apparatus for optically inspecting nuclear fuel pellets for surface flaws. The inspection system includes a prism and lens arrangement for scanning the surface of each pellet as the same is rotated. The resulting scan produces data indicative of the extent and shape of each flaw which is employed to generate a flaw quality index for each detected flaw. The flaw quality indexes from all flaws are summed and compared with an acceptable surface quality index. The result of the comparison is utilized to control the acceptance or rejection of the pellet.
NASA Astrophysics Data System (ADS)
Louzon, E.
1989-12-01
Quality, cost, and schedule are three factors affecting the competitiveness of a company; they require balancing so that products of acceptable quality are delivered, on time and at a competitive cost. Quality costs comprise investment in quality maintenance and failure costs which arise from failure to maintain standards. The basic principle for achieving the required quality at minimum cost is that of prevention of failures, etc., through production control, attention to manufacturing practices, and appropriate management and training. Total quality control involves attention to the product throughout its life cycle, including in-service performance evaluation, servicing, and maintenance.
Iqbal, Sahar; Mustansar, Tazeen
2017-03-01
Sigma is a metric that quantifies the performance of a process as a rate of Defects-Per-Million opportunities. In clinical laboratories, sigma metric analysis is used to assess the performance of laboratory process system. Sigma metric is also used as a quality management strategy for a laboratory process to improve the quality by addressing the errors after identification. The aim of this study is to evaluate the errors in quality control of analytical phase of laboratory system by sigma metric. For this purpose sigma metric analysis was done for analytes using the internal and external quality control as quality indicators. Results of sigma metric analysis were used to identify the gaps and need for modification in the strategy of laboratory quality control procedure. Sigma metric was calculated for quality control program of ten clinical chemistry analytes including glucose, chloride, cholesterol, triglyceride, HDL, albumin, direct bilirubin, total bilirubin, protein and creatinine, at two control levels. To calculate the sigma metric imprecision and bias was calculated with internal and external quality control data, respectively. The minimum acceptable performance was considered as 3 sigma. Westgard sigma rules were applied to customize the quality control procedure. Sigma level was found acceptable (≥3) for glucose (L2), cholesterol, triglyceride, HDL, direct bilirubin and creatinine at both levels of control. For rest of the analytes sigma metric was found <3. The lowest value for sigma was found for chloride (1.1) at L2. The highest value of sigma was found for creatinine (10.1) at L3. HDL was found with the highest sigma values at both control levels (8.8 and 8.0 at L2 and L3, respectively). We conclude that analytes with the sigma value <3 are required strict monitoring and modification in quality control procedure. In this study application of sigma rules provided us the practical solution for improved and focused design of QC procedure.
Dozier, Samantha; Brown, Jeffrey; Currie, Alistair
2011-01-01
Simple Summary Many vaccines are tested for quality in experiments that require the use of large numbers of animals in procedures that often cause significant pain and distress. Newer technologies have fostered the development of vaccine quality control tests that reduce or eliminate the use of animals, but the availability of these newer methods has not guaranteed their acceptance by regulators or use by manufacturers. We discuss a strategic approach that has been used to assess and ultimately increase the use of non-animal vaccine quality tests in the U.S. and U.K. Abstract In recent years, technologically advanced high-throughput techniques have been developed that replace, reduce or refine animal use in vaccine quality control tests. Following validation, these tests are slowly being accepted for use by international regulatory authorities. Because regulatory acceptance itself has not guaranteed that approved humane methods are adopted by manufacturers, various organizations have sought to foster the preferential use of validated non-animal methods by interfacing with industry and regulatory authorities. After noticing this gap between regulation and uptake by industry, we began developing a paradigm that seeks to narrow the gap and quicken implementation of new replacement, refinement or reduction guidance. A systematic analysis of our experience in promoting the transparent implementation of validated non-animal vaccine potency assays has led to the refinement of our paradigmatic process, presented here, by which interested parties can assess the local regulatory acceptance of methods that reduce animal use and integrate them into quality control testing protocols, or ensure the elimination of peripheral barriers to their use, particularly for potency and other tests carried out on production batches. PMID:26486625
Ueno, Tamio; Matuda, Junichi; Yamane, Nobuhisa
2013-03-01
To evaluate the occurrence of out-of acceptable ranges and accuracy of antimicrobial susceptibility tests, we applied a new statistical tool to the Inter-Laboratory Quality Control Program established by the Kyushu Quality Control Research Group. First, we defined acceptable ranges of minimum inhibitory concentration (MIC) for broth microdilution tests and inhibitory zone diameter for disk diffusion tests on the basis of Clinical and Laboratory Standards Institute (CLSI) M100-S21. In the analysis, more than two out-of acceptable range results in the 20 tests were considered as not allowable according to the CLSI document. Of the 90 participating laboratories, 46 (51%) experienced one or more occurrences of out-of acceptable range results. Then, a binomial test was applied to each participating laboratory. The results indicated that the occurrences of out-of acceptable range results in the 11 laboratories were significantly higher when compared to the CLSI recommendation (allowable rate < or = 0.05). The standard deviation indices(SDI) were calculated by using reported results, mean and standard deviation values for the respective antimicrobial agents tested. In the evaluation of accuracy, mean value from each laboratory was statistically compared with zero using a Student's t-test. The results revealed that 5 of the 11 above laboratories reported erroneous test results that systematically drifted to the side of resistance. In conclusion, our statistical approach has enabled us to detect significantly higher occurrences and source of interpretive errors in antimicrobial susceptibility tests; therefore, this approach can provide us with additional information that can improve the accuracy of the test results in clinical microbiology laboratories.
NASA Technical Reports Server (NTRS)
Grantham, William D.; Person, Lee H., Jr.; Brown, Philip W.; Becker, Lawrence E.; Hunt, George E.; Rising, J. J.; Davis, W. J.; Willey, C. S.; Weaver, W. A.; Cokeley, R.
1985-01-01
Piloted simulation studies have been conducted to evaluate the effectiveness of two pitch active control systems (PACS) on the flying qualities of a wide-body transport airplane when operating at negative static margins. These two pitch active control systems consisted of a simple 'near-term' PACS and a more complex 'advanced' PACS. Eight different flight conditions, representing the entire flight envelope, were evaluated with emphasis on the cruise flight conditions. These studies were made utilizing the Langley Visual/Motion Simulator (VMS) which has six degrees of freedom. The simulation tests indicated that (1) the flying qualities of the baseline aircraft (PACS off) for the cruise and other high-speed flight conditions were unacceptable at center-of-gravity positions aft of the neutral static stability point; (2) within the linear static stability flight envelope, the near-term PACS provided acceptable flying qualities for static stabilty margins to -3 percent; and (3) with the advanced PACS operative, the flying qualities were demonstrated to be good (satisfactory to very acceptable) for static stabilty margins to -20 percent.
Strategies for coping with pain presented by adolescents with hematopoietic malignancies.
Cepuch, Grazyna; Wojnar-Gruszka, Katarzyna; Kowalczyk, Marta
2012-01-01
Leukaemias and lymphomas are the most common malignant diseases diagnosed among adolescents and they are associated with pain and anxiety. As a result they may affect the way patients accept their disease and determine subjective assessment of quality of life. The objective of this study was to recognise strategies for coping with pain, evaluate the process of accepting the disease and assess quality of life among adolescents diagnosed with hematopoietic malignancies. The study group comprised 66 patients aged between 14 and 21 and diagnosed with leukaemia or lymphoma. The following measuring tools were used: the Pain Coping Strategies Questionnaire (CSQ), Zung Self-Rating Anxiety Scale (SAS), Acceptance of Illness Scale (AIS), and WHOQOL-BREF for quality of life evaluation. Coping self-statements and praying or hoping were the two most common strategies used by our respondents when coping with pain. In the study group the level of anxiety had no influence on pain control and the ability to reduce it. A statistically significant relation was found between the level of catastrophizing as a method of coping with pain and quality of life in the physical domain. An additional correlation was observed between quality of life in the psychological domain and the level of pain control. The ability of coping with pain promotes the acceptance of illness and improves patient's quality of life. The age and duration of the disease were factors affecting strategies for coping with pain. A small percentage of respondents who experienced anxiety suggests that further and deeper research is needed in this field.
Approaches to quality management and accreditation in a genetic testing laboratory
Berwouts, Sarah; Morris, Michael A; Dequeker, Elisabeth
2010-01-01
Medical laboratories, and specifically genetic testing laboratories, provide vital medical services to different clients: clinicians requesting a test, patients from whom the sample was collected, public health and medical-legal instances, referral laboratories and authoritative bodies. All expect results that are accurate and obtained in an efficient and effective manner, within a suitable time frame and at acceptable cost. There are different ways of achieving the end results, but compliance with International Organization for Standardization (ISO) 15189, the international standard for the accreditation of medical laboratories, is becoming progressively accepted as the optimal approach to assuring quality in medical testing. We present recommendations and strategies designed to aid genetic testing laboratories with the implementation of a quality management system, including key aspects such as document control, external quality assessment, internal quality control, internal audit, management review, validation, as well as managing the human side of change. The focus is on pragmatic approaches to attain the levels of quality management and quality assurance required for accreditation according to ISO 15189, within the context of genetic testing. Attention is also given to implementing efficient and effective quality improvement. PMID:20720559
Gynecologic Oncology Group quality assurance audits: analysis and initiatives for improvement.
Blessing, John A; Bialy, Sally A; Whitney, Charles W; Stonebraker, Bette L; Stehman, Frederick B
2010-08-01
The Gynecologic Oncology Group (GOG) is a multi-institution, multi-discipline Cooperative Group funded by the National Cancer Institute (NCI) to conduct clinical trials which investigate the treatment, prevention, control, quality of survivorship, and translational science of gynecologic malignancies. In 1982, the NCI initiated a program of on-site quality assurance audits of participating institutions. Each is required to be audited at least once every 3 years. In GOG, the audit mandate is the responsibility of the GOG Quality Assurance Audit Committee and it is centralized in the Statistical and Data Center (SDC). Each component (Regulatory, Investigational Drug Pharmacy, Patient Case Review) is classified as Acceptable, Acceptable, follow-up required, or Unacceptable. To determine frequently occurring deviations and develop focused innovative solutions to address them. A database was created to examine the deviations noted at the most recent audit conducted at 57 GOG parent institutions during 2004-2007. Cumulatively, this involved 687 patients and 306 protocols. The results documented commendable performance: Regulatory (39 Acceptable, 17 Acceptable, follow-up, 1 Unacceptable); Pharmacy (41 Acceptable, 3 Acceptable, follow-up, 1 Unacceptable, 12 N/A): Patient Case Review (31 Acceptable, 22 Acceptable, follow-up, 4 Unacceptable). The nature of major and lesser deviations was analyzed to create and enhance initiatives for improvement of the quality of clinical research. As a result, Group-wide proactive initiatives were undertaken, audit training sessions have emphasized recurring issues, and GOG Data Management Subcommittee agendas have provided targeted instruction and training. The analysis was based upon parent institutions only; affiliate institutions and Community Clinical Oncology Program participants were not included, although it is assumed their areas of difficulty are similar. The coordination of the GOG Quality Assurance Audit program in the SDC has improved data quality by enhancing our ability to identify frequently occurring deviations and develop innovative solutions to avoid or minimize their occurrence in the future.
Effects of side-stick controllers on rotorcraft handling qualities for terrain flight
NASA Technical Reports Server (NTRS)
Aiken, E. W.
1985-01-01
Pertinent fixed and rotary-wing feasibility studies and handling-qualities research programs are reviewed and the effects of certain controller characteristics on handling qualities for specific rotorcraft flight tasks are summarized. The effects of the controller force-deflection relationship and the number of controlled axes that are integrated in a single controller are examined. Simulation studies were conducted which provide a significant part of the available handling qualities data. The studies demonstrate the feasibility of using a single, properly designed, limited-displacement, multiaxis controller for certain relatively routine flight tasks in a two-crew rotorcraft with nominal levels of stability and control augmentation with a high degree of reliability are incorporated, separated three or two-axis controller configurations are required for acceptable handling qualities.
10 CFR 32.110 - Acceptance sampling procedures under certain specific licenses.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 1 2011-01-01 2011-01-01 false Acceptance sampling procedures under certain specific licenses. 32.110 Section 32.110 Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER CERTAIN ITEMS CONTAINING BYPRODUCT MATERIAL Quality Control Sampling Procedures § 32...
10 CFR 32.110 - Acceptance sampling procedures under certain specific licenses.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 1 2010-01-01 2010-01-01 false Acceptance sampling procedures under certain specific licenses. 32.110 Section 32.110 Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES TO MANUFACTURE OR TRANSFER CERTAIN ITEMS CONTAINING BYPRODUCT MATERIAL Quality Control Sampling Procedures § 32...
Association of journal quality indicators with methodological quality of clinical research articles.
Lee, Kirby P; Schotland, Marieka; Bacchetti, Peter; Bero, Lisa A
2002-06-05
The ability to identify scientific journals that publish high-quality research would help clinicians, scientists, and health-policy analysts to select the most up-to-date medical literature to review. To assess whether journal characteristics of (1) peer-review status, (2) citation rate, (3) impact factor, (4) circulation, (5) manuscript acceptance rate, (6) MEDLINE indexing, and (7) Brandon/Hill Library List indexing are predictors of methodological quality of research articles, we conducted a cross-sectional study of 243 original research articles involving human subjects published in general internal medical journals. The mean (SD) quality score of the 243 articles was 1.37 (0.22). All journals reported a peer-review process and were indexed on MEDLINE. In models that controlled for article type (randomized controlled trial [RCT] or non-RCT), journal citation rate was the most statistically significant predictor (0.051 increase per doubling; 95% confidence interval [CI], 0.037-0.065; P<.001). In separate analyses by article type, acceptance rate was the strongest predictor for RCT quality (-0.113 per doubling; 95% CI, -0.148 to -0.078; P<.001), while journal citation rate was the most predictive factor for non-RCT quality (0.051 per doubling; 95% CI, 0.044-0.059; P<.001). High citation rates, impact factors, and circulation rates, and low manuscript acceptance rates and indexing on Brandon/Hill Library List appear to be predictive of higher methodological quality scores for journal articles.
Chung, Oi Kwan Joyce; Li, Ho Cheung William; Chiu, Sau Ying; Ho, Ka Yan; Lopez, Violeta
2015-01-01
Physical activity is of paramount importance to enhance the quality of life of childhood cancer survivors. The objectives of this study were to examine the sustainability, feasibility, and acceptability of an adventure-based training and health education program in changing the exercise behavior and enhancing the physical activity levels, self-efficacy, and quality of life of childhood cancer survivors. A follow-up study (12 and 18 months) of a previous study was conducted. Participants in the experimental group (n = 33) joined a 4-day integrated adventure-based training and health education program. The control group (n = 36) received the standard medical care. Changes in exercise behavior, levels of physical activity, self-efficacy, and quality of life were assessed from the time of recruitment, and at 12 and 18 months after starting the intervention. Process evaluation was conducted to determine whether the program was feasible and acceptable to participants. From baseline to 18 months after the intervention, the experimental group reported statistically significant differences in the stages of change in physical activity and higher levels of physical activity, self-efficacy, and quality of life than did the control group. The results of process evaluation revealed that the program was both feasible and acceptable to participants. The program was found to have substantial effects on enhancing the physical activity levels, self-efficacy, and quality of life of childhood cancer survivors over at least 18 months. Healthcare professionals should consider adopting such programs to promote the regular physical activity among childhood cancer survivors.
The psychology of drinking water quality: An exploratory study
NASA Astrophysics Data System (ADS)
Syme, Geoffrey J.; Williams, Katrina D.
1993-12-01
Perceptions of drinking water quality were measured for residents at four locations in Western Australia. The total dissolved solid levels for the locations varied. Four scales of drinking water satisfaction were measured: acceptability of water quality; water quality risk judgment; perception of neighborhood water quality; and attitudes toward fluoride as an additive. Responses to each of these scales did not appear to be highly related to total dissolved solids. The relationship between attitudes toward water quality and a variety of psychological, attitudinal, experiential, and demographic variables was investigated. It was found that responses to the acceptability of water quality and water quality risk judgment scales related to perceived credibility of societal institutions and feelings of control over water quality and environmental problems. For the remaining two scales few significant correlations were found. The results support those who advocate localized information and involvement campaigns on drinking water quality issues.
Mantella, Nicole M; Youngentob, Steven L
2014-01-01
Human studies indicate that alcohol exposure during gestation not only increases the chance for later alcohol abuse, but also nicotine dependence. The flavor attributes of both alcohol and nicotine can be important determinants of their initial acceptance and they both share the component chemosensory qualities of an aversive odor, bitter taste and oral irritation. There is a growing body of evidence demonstrating epigenetic chemosensory mechanisms through which fetal alcohol exposure increases adolescent alcohol acceptance, in part, by decreasing the aversion to alcohol's bitter and oral irritation qualities, as well as its odor. Given that alcohol and nicotine have noteworthy chemosensory qualities in common, we investigated whether fetal exposure to alcohol increased the acceptability of nicotine's odor and taste in adolescent rats. Study rats were alcohol-exposed during fetal development via the dams' liquid diet. Control animals received ad lib access to an iso-caloric, iso-nutritive diet throughout gestation. Odorant-induced innate behavioral responses to nicotine odor (Experiment 1) or orosensory-mediated responses to nicotine solutions (Experiment 2) were obtained, using whole-body plethysmography and brief access lick tests, respectively. Compared to controls, rats exposed to fetal alcohol showed an enhanced nicotine odor response that was paralleled by increased oral acceptability of nicotine. Given the common aversive component qualities imbued in the flavor profiles of both drugs, our findings demonstrate that like postnatal alcohol avidity, fetal alcohol exposure also influences nicotine acceptance, at a minimum, by decreasing the aversion of both its smell and taste. Moreover, they highlight potential chemosensory-based mechanism(s) by which fetal alcohol exposure increases the later initial risk for nicotine use, thereby contributing to the co-morbid expression with enhanced alcohol avidity. Where common chemosensory mechanisms are at play, our results suggest broader implications related to the consequence of fetal exposure with one substance of abuse and initial acceptability of others.
Mantella, Nicole M.; Youngentob, Steven L.
2014-01-01
Human studies indicate that alcohol exposure during gestation not only increases the chance for later alcohol abuse, but also nicotine dependence. The flavor attributes of both alcohol and nicotine can be important determinants of their initial acceptance and they both share the component chemosensory qualities of an aversive odor, bitter taste and oral irritation. There is a growing body of evidence demonstrating epigenetic chemosensory mechanisms through which fetal alcohol exposure increases adolescent alcohol acceptance, in part, by decreasing the aversion to alcohol's bitter and oral irritation qualities, as well as its odor. Given that alcohol and nicotine have noteworthy chemosensory qualities in common, we investigated whether fetal exposure to alcohol increased the acceptability of nicotine's odor and taste in adolescent rats. Study rats were alcohol-exposed during fetal development via the dams' liquid diet. Control animals received ad lib access to an iso-caloric, iso-nutritive diet throughout gestation. Odorant-induced innate behavioral responses to nicotine odor (Experiment 1) or orosensory-mediated responses to nicotine solutions (Experiment 2) were obtained, using whole-body plethysmography and brief access lick tests, respectively. Compared to controls, rats exposed to fetal alcohol showed an enhanced nicotine odor response that was paralleled by increased oral acceptability of nicotine. Given the common aversive component qualities imbued in the flavor profiles of both drugs, our findings demonstrate that like postnatal alcohol avidity, fetal alcohol exposure also influences nicotine acceptance, at a minimum, by decreasing the aversion of both its smell and taste. Moreover, they highlight potential chemosensory-based mechanism(s) by which fetal alcohol exposure increases the later initial risk for nicotine use, thereby contributing to the co-morbid expression with enhanced alcohol avidity. Where common chemosensory mechanisms are at play, our results suggest broader implications related to the consequence of fetal exposure with one substance of abuse and initial acceptability of others. PMID:25029285
The quest for performance-related specifications for hydraulic cement concrete.
DOT National Transportation Integrated Search
1982-01-01
This paper reviews some of the problems associated with quality assurance for hydraulic cement concrete and the difficulties of relating the results of quality control and acceptance testing to the performance of the concrete facility. The importance...
QC/QA : evaluation of effectiveness in Kentucky.
DOT National Transportation Integrated Search
2008-06-30
Quality control and quality assurance in the highway industry is going through a cultural shift. There is a growing trend toward using the contractor data for acceptance and payment purpose. This has led to serious concerns about conflicts of interes...
Dahlin, Mats; Andersson, Gerhard; Magnusson, Kristoffer; Johansson, Tomas; Sjögren, Johan; Håkansson, Andreas; Pettersson, Magnus; Kadowaki, Åsa; Cuijpers, Pim; Carlbring, Per
2016-02-01
Generalized anxiety disorder (GAD) is a disabling condition which can be treated with cognitive behaviour therapy (CBT). The present study tested the effects of therapist-guided internet-delivered acceptance-based behaviour therapy on symptoms of GAD and quality of life. An audio CD with acceptance and mindfulness exercises and a separate workbook were also included in the treatment. Participants diagnosed with GAD (N = 103) were randomly allocated to immediate therapist-guided internet-delivered acceptance-based behaviour therapy or to a waiting-list control condition. A six month follow-up was also included. Results using hierarchical linear modelling showed moderate to large effects on symptoms of GAD (Cohen's d = 0.70 to 0.98), moderate effects on depressive symptoms (Cohen's d = 0.51 to 0.56), and no effect on quality of life. Follow-up data showed maintained effects. While there was a 20% dropout rate, sensitivity analyses showed that dropouts did not differ in their degree of change during treatment. To conclude, our study suggests that internet-delivered acceptance-based behaviour therapy can be effective in reducing the symptoms of GAD. Copyright © 2015 Elsevier Ltd. All rights reserved.
In my experience: quality control of symposia and their published proceedings
J. Michael Scott; C. John Ralph
1988-01-01
The lack of quality in symposia proceedings has recently been criticized by Bart and Anderson (1981). Their criticisms elicited 2 defenses of publishing symposia proceedings (Ca- pen 1982, Finch et al. 1982). These authors offered excellent suggestions for improving the quality of published proceedings: review papers before acceptance; use outside reviewers; request...
Valsangkar, Sameer; Bodhare, Trupti; Bele, Samir; Sai, Surendranath
2011-05-01
The effect of infertility on marital and sexual functioning, health-related quality of life (QoL) and the acceptability of the treatment modalities is a poorly researched area in India. To measure and compare the impact of infertility on marital adjustment, sexual functioning, QoL and the acceptability of various treatment modalities in infertility. Hospital-based cross-sectional controlled study. Data regarding infertility, socio-demographic characteristics and treatment acceptability was obtained via a semi-structured questionnaire. validated, standardized scales were used to measure marital adjustment (abbreviated dyadic adjustment scale), sexual functioning (abbreviated sexual functioning questionnaire) in cases and controls, and quality of life (FertiQol) in cases. Data from 106 women attending tertiary infertility centers who met the definition of primary infertility and 212 controls attending the medical outpatient department in the same centers was obtained. Body mass index and socioeconomic status were significant (P < 0.006 and < 0.0001 respectively) for infertility. Fertility-enhancing regimens and adoption had the highest acceptability with a wide dispersion of range for adoption and least acceptance for sperm, egg, embryo donation and surrogate motherhood. Logistic regression analysis revealed a significant effect size of infertility on marital adjustment (Nagelkerke R(2) 0.725, Cohen's D 0.86) and sexual functioning (Nagelkerke R(2) 0.73, Cohen's D 0.815). QoL showed a decrease in mean scores on the FertiQol scale similar to normative data. Effective counseling, reassurance and measures to reduce the impact of the condition on marital and sexual life, overall QoL are needed to impart a holistic treatment in infertility.
Valsangkar, Sameer; Bodhare, Trupti; Bele, Samir; Sai, Surendranath
2011-01-01
BACKGROUND: The effect of infertility on marital and sexual functioning, health-related quality of life (QoL) and the acceptability of the treatment modalities is a poorly researched area in India. AIMS AND OBJECTIVES: To measure and compare the impact of infertility on marital adjustment, sexual functioning, QoL and the acceptability of various treatment modalities in infertility. DESIGN AND SETTING: Hospital-based cross-sectional controlled study. MATERIALS AND METHODS: Data regarding infertility, socio-demographic characteristics and treatment acceptability was obtained via a semi-structured questionnaire. validated, standardized scales were used to measure marital adjustment (abbreviated dyadic adjustment scale), sexual functioning (abbreviated sexual functioning questionnaire) in cases and controls, and quality of life (FertiQol) in cases. Data from 106 women attending tertiary infertility centers who met the definition of primary infertility and 212 controls attending the medical outpatient department in the same centers was obtained. RESULTS: Body mass index and socioeconomic status were significant (P < 0.006 and < 0.0001 respectively) for infertility. Fertility-enhancing regimens and adoption had the highest acceptability with a wide dispersion of range for adoption and least acceptance for sperm, egg, embryo donation and surrogate motherhood. Logistic regression analysis revealed a significant effect size of infertility on marital adjustment (Nagelkerke R2 0.725, Cohen's D 0.86) and sexual functioning (Nagelkerke R2 0.73, Cohen's D 0.815). QoL showed a decrease in mean scores on the FertiQol scale similar to normative data. CONCLUSIONS: Effective counseling, reassurance and measures to reduce the impact of the condition on marital and sexual life, overall QoL are needed to impart a holistic treatment in infertility. PMID:22065832
HPLC for quality control of polyimides
NASA Technical Reports Server (NTRS)
Young, P. R.; Sykes, G. F.
1979-01-01
High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.
O'Connor, Martin; Munnelly, Anita; Whelan, Robert; McHugh, Louise
2018-05-01
eHealth is an innovative method of delivering therapeutic content with the potential to improve access to third-wave behaviural and cognitive therapies. This systematic review and meta-analysis aimed to determine the efficacy and acceptability of third-wave eHealth treatments in improving mental health outcomes. A comprehensive search of electronic bibliographic databases including PubMed, PsycINFO, Web of Science, and CENTRAL was conducted to identify randomized controlled trials of third-wave treatments in which eHealth was the main component. Twenty-one studies were included in the review. Meta-analyses revealed that third-wave eHealth significantly outperformed inactive control conditions in improving anxiety, depression, and quality-of-life outcomes and active control conditions in alleviating anxiety and depression with small to medium effect sizes. No statistically significant differences were found relative to comparison interventions. Findings from a narrative synthesis of participant evaluation outcomes and meta-analysis of participant attrition rates provided preliminary support for the acceptability of third-wave eHealth. Third-wave eHealth treatments are efficacious in improving mental health outcomes including anxiety, depression, and quality of life, but not more so than comparison interventions. Preliminary evidence from indices of participant evaluation and attrition rates supports the acceptability of these treatments. Copyright © 2017. Published by Elsevier Ltd.
Quality of mixed tropical fruit following irradiation treatment
USDA-ARS?s Scientific Manuscript database
Irradiation can be used to control quarantine insect pests of fresh fruits and vegetables. The economic viability of irradiation improves if a diversity of crops can be treated, but the quality of irradiated produce determines market acceptance. Many tropical fruit tolerate irradiation doses less th...
New technologies for field-portable monitoring instruments often have a long lead time in development and authorization. Some obstacles to the acceptance of these pilot technologies include concern about liabilities, reluctance to take risks on new technologies, and uncertainty a...
Shanks, Orin C; Kelty, Catherine A; Oshiro, Robin; Haugland, Richard A; Madi, Tania; Brooks, Lauren; Field, Katharine G; Sivaganesan, Mano
2016-05-01
There is growing interest in the application of human-associated fecal source identification quantitative real-time PCR (qPCR) technologies for water quality management. The transition from a research tool to a standardized protocol requires a high degree of confidence in data quality across laboratories. Data quality is typically determined through a series of specifications that ensure good experimental practice and the absence of bias in the results due to DNA isolation and amplification interferences. However, there is currently a lack of consensus on how best to evaluate and interpret human fecal source identification qPCR experiments. This is, in part, due to the lack of standardized protocols and information on interlaboratory variability under conditions for data acceptance. The aim of this study is to provide users and reviewers with a complete series of conditions for data acceptance derived from a multiple laboratory data set using standardized procedures. To establish these benchmarks, data from HF183/BacR287 and HumM2 human-associated qPCR methods were generated across 14 laboratories. Each laboratory followed a standardized protocol utilizing the same lot of reference DNA materials, DNA isolation kits, amplification reagents, and test samples to generate comparable data. After removal of outliers, a nested analysis of variance (ANOVA) was used to establish proficiency metrics that include lab-to-lab, replicate testing within a lab, and random error for amplification inhibition and sample processing controls. Other data acceptance measurements included extraneous DNA contamination assessments (no-template and extraction blank controls) and calibration model performance (correlation coefficient, amplification efficiency, and lower limit of quantification). To demonstrate the implementation of the proposed standardized protocols and data acceptance criteria, comparable data from two additional laboratories were reviewed. The data acceptance criteria proposed in this study should help scientists, managers, reviewers, and the public evaluate the technical quality of future findings against an established benchmark. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Sanders, Matthew R.; McKinlay, Lynne; Boyd, Roslyn N.
2016-01-01
Objective To examine the effects of Stepping Stones Triple P (SSTP) and Acceptance and Commitment Therapy (ACT) on child functioning, quality of life, and parental adjustment. Method 67 parents (97.0% mothers) of children (64.2% male; mean age 5.3 ± 3.0 years) with cerebral palsy participated in a randomized controlled trial with three groups: wait-list control, SSTP, and SSTP + ACT. This article details the secondary outcomes. Results In comparison with wait-list, the SSTP + ACT group showed increased functional performance and quality of life as well as decreased parental psychological symptoms. No differences were found for parental confidence. No differences were found between SSTP and wait-list or between SSTP and SSTP + ACT. Conclusions ACT-integrated parenting intervention may be an effective way to target child functioning, quality of life, and parental adjustment. PMID:26702629
Emperical Tests of Acceptance Sampling Plans
NASA Technical Reports Server (NTRS)
White, K. Preston, Jr.; Johnson, Kenneth L.
2012-01-01
Acceptance sampling is a quality control procedure applied as an alternative to 100% inspection. A random sample of items is drawn from a lot to determine the fraction of items which have a required quality characteristic. Both the number of items to be inspected and the criterion for determining conformance of the lot to the requirement are given by an appropriate sampling plan with specified risks of Type I and Type II sampling errors. In this paper, we present the results of empirical tests of the accuracy of selected sampling plans reported in the literature. These plans are for measureable quality characteristics which are known have either binomial, exponential, normal, gamma, Weibull, inverse Gaussian, or Poisson distributions. In the main, results support the accepted wisdom that variables acceptance plans are superior to attributes (binomial) acceptance plans, in the sense that these provide comparable protection against risks at reduced sampling cost. For the Gaussian and Weibull plans, however, there are ranges of the shape parameters for which the required sample sizes are in fact larger than the corresponding attributes plans, dramatically so for instances of large skew. Tests further confirm that the published inverse-Gaussian (IG) plan is flawed, as reported by White and Johnson (2011).
21 CFR 212.70 - What controls and acceptance criteria must I have for my finished PET drug products?
Code of Federal Regulations, 2011 CFR
2011-04-01
... for my finished PET drug products? 212.70 Section 212.70 Food and Drugs FOOD AND DRUG ADMINISTRATION... acceptance criteria must I have for my finished PET drug products? (a) Specifications. You must establish specifications for each PET drug product, including criteria for determining identity, strength, quality, purity...
21 CFR 212.70 - What controls and acceptance criteria must I have for my finished PET drug products?
Code of Federal Regulations, 2013 CFR
2013-04-01
... for my finished PET drug products? 212.70 Section 212.70 Food and Drugs FOOD AND DRUG ADMINISTRATION... acceptance criteria must I have for my finished PET drug products? (a) Specifications. You must establish specifications for each PET drug product, including criteria for determining identity, strength, quality, purity...
21 CFR 212.70 - What controls and acceptance criteria must I have for my finished PET drug products?
Code of Federal Regulations, 2014 CFR
2014-04-01
... for my finished PET drug products? 212.70 Section 212.70 Food and Drugs FOOD AND DRUG ADMINISTRATION... acceptance criteria must I have for my finished PET drug products? (a) Specifications. You must establish specifications for each PET drug product, including criteria for determining identity, strength, quality, purity...
21 CFR 212.70 - What controls and acceptance criteria must I have for my finished PET drug products?
Code of Federal Regulations, 2012 CFR
2012-04-01
... for my finished PET drug products? 212.70 Section 212.70 Food and Drugs FOOD AND DRUG ADMINISTRATION... acceptance criteria must I have for my finished PET drug products? (a) Specifications. You must establish specifications for each PET drug product, including criteria for determining identity, strength, quality, purity...
ERIC Educational Resources Information Center
Roemer, Lizabeth; Orsillo, Susan M.; Salters-Pedneault, Kristalyn
2008-01-01
Generalized anxiety disorder (GAD) is a chronic anxiety disorder, associated with comorbidity and impairment in quality of life, for which improved psychosocial treatments are needed. GAD is also associated with reactivity to and avoidance of internal experiences. The current study examined the efficacy of an acceptance-based behavioral therapy…
29 CFR 1910.7 - Definition and requirements for a nationally recognized testing laboratory.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., written testing procedures, and calibration and quality control programs) to perform: (i) Testing and... test standards; or (ii) Experimental testing and examining of equipment and materials for workplace..., labeled, or accepted, the following controls or services: (i) Implements control procedures for...
Katcher, Heather I; Ferdowsian, Hope R; Hoover, Valerie J; Cohen, Joshua L; Barnard, Neal D
2010-01-01
Vegetarian and vegan diets are effective in preventing and treating several chronic diseases. However, their acceptability outside a clinical trial setting has not been extensively studied. The aim of this study was to determine the acceptability of a worksite vegan nutrition program and its effects on health-related quality of life and work productivity. Employees of a major insurance corporation with a body mass index > or =25 kg/m(2) and/or a previous diagnosis of type 2 diabetes received either weekly group instruction on a low-fat vegan diet (n = 68) or received no diet instruction (n = 45) for 22 weeks. The vegan group reported improvements in general health (p = 0.002), physical functioning (p = 0.001), mental health (p = 0.03), vitality (p = 0.004), and overall diet satisfaction (p < 0.001) compared with the control group. The vegan group also reported a decrease in food costs (p = 0.003), and increased difficulty finding foods when eating out (p = 0.04) compared with the control group. The vegan group reported a 40-46% decrease in health-related productivity impairments at work (p = 0.03) and in regular daily activities (p = 0.004). A worksite vegan nutrition program is well-accepted and can be implemented by employers to improve the health, quality of life, and work productivity of employees.
Computer graphics for quality control in the INAA of geological samples
Grossman, J.N.; Baedecker, P.A.
1987-01-01
A data reduction system for the routine instrumental activation analysis of samples is described, with particular emphasis on interactive graphics capabilities for evaluating analytical quality. Graphics procedures have been developed to interactively control the analysis of selected photopeaks during spectral analysis, and to evaluate detector performance during a given counting cycle. Graphics algorithms are also used to compare the data on reference samples with accepted values, to prepare quality control charts to evaluate long term precision and to search for systematic variations in data on reference samples as a function of time. ?? 1987 Akade??miai Kiado??.
King, Kevin M; McLaughlin, Katie A; Silk, Jennifer; Monahan, Kathryn C
2017-11-21
Adolescence is a critical period for the development of self-regulation, and peer interactions are thought to strongly influence regulation ability. Simple exposure to peers has been found to alter decisions about risky behaviors and increase sensitivity to rewards. The link between peer exposure and self-regulation is likely to vary as a function of the type and quality of peer interaction (e.g., rejection or acceptance). Little is known about how the nature of interactions with peers influences different dimensions of self-regulation. We examined how randomization to acceptance or rejection by online "virtual" peers influenced multiple dimensions of self-regulation in a multisite community sample of 273 adolescents aged 16-17 years. Compared to a neutral condition, exposure to peers produced increases in cold cognitive control, but decreased hot cognitive control. Relative to peer acceptance, peer rejection reduced distress tolerance and increased sensitivity to losses. These findings suggest that different dimensions of adolescent self-regulation are influenced by the nature of the peer context: basic cognitive functions are altered by mere exposure to peers, whereas more complex decision making and emotion regulation processes are influenced primarily by the quality of that exposure.
Harvey A. Holt
1989-01-01
Controlling individual unwanted trees in forest stands is a readily accepted method for improving the value of future harvests. The practice is especially important in mixed hardwood forests where species differ considerably in value and within species individual trees differ in quality. Individual stem control is a mechanical or chemical weeding operation that...
It is generally accepted that water quality can deteriorate in a distribution system through reactions in the bulk phase and/or at the pipe wall. These reactions may be physical, chemical and/or microbiological in nature. Perhaps one of the most serious aspects of water quality...
The Health Educator as Death Educator: Professional Preparation and Quality Control.
ERIC Educational Resources Information Center
Crase, Darrell
1980-01-01
Health education curriculum has responded to the need to include teacher preparation experiences in death education. While death education is gaining wide acceptance, little effort has been made to guarantee quality instruction. A list of competencies are provided for the edification of the effective death educator. (JN)
DOT National Transportation Integrated Search
2015-01-01
One of the objectives of this study was to evaluate soil testing equipment based on its capability of measuring in-place stiffness or modulus values. : As design criteria transition from empirical to mechanistic-empirical, soil test methods and equip...
Jayakody, Chatura; Hull-Ryde, Emily A
2016-01-01
Well-defined quality control (QC) processes are used to determine whether a certain procedure or action conforms to a widely accepted standard and/or set of guidelines, and are important components of any laboratory quality assurance program (Popa-Burke et al., J Biomol Screen 14: 1017-1030, 2009). In this chapter, we describe QC procedures useful for monitoring the accuracy and precision of laboratory instrumentation, most notably automated liquid dispensers. Two techniques, gravimetric QC and photometric QC, are highlighted in this chapter. When used together, these simple techniques provide a robust process for evaluating liquid handler accuracy and precision, and critically underpin high-quality research programs.
Ducar, Constance; Smith, Donna; Pinzon, Cris; Stirewalt, Michael; Cooper, Cristine; McElrath, M. Juliana; Hural, John
2014-01-01
The HIV Vaccine Trials Network (HVTN) is a global network of 28 clinical trial sites dedicated to identifying an effective HIV vaccine. Cryopreservation of high-quality peripheral blood mononuclear cells (PBMC) is critical for the assessment of vaccine-induced cellular immune functions. The HVTN PBMC Quality Management Program is designed to ensure viable PBMC are processed, stored and shipped for clinical trial assays from all HVTN clinical trial sites. The program has evolved by developing and incorporating best practices for laboratory and specimen quality and implementing automated, web-based tools. These tools allow the site-affiliated processing laboratories and the central Laboratory Operations Unit to rapidly collect, analyze and report PBMC quality data. The HVTN PBMC Quality Management Program includes five key components: 1) Laboratory Assessment, 2) PBMC Training and Certification, 3) Internal Quality Control, 4) External Quality Control (EQC), and 5) Assay Specimen Quality Control. Fresh PBMC processing data is uploaded from each clinical site processing laboratory to a central HVTN Statistical and Data Management Center database for access and analysis on a web portal. Samples are thawed at a central laboratory for assay or specimen quality control and sample quality data is uploaded directly to the database by the central laboratory. Four year cumulative data covering 23,477 blood draws reveals an average fresh PBMC yield of 1.45×106 ±0.48 cells per milliliter of useable whole blood. 95% of samples were within the acceptable range for fresh cell yield of 0.8–3.2×106 cells/ml of usable blood. Prior to full implementation of the HVTN PBMC Quality Management Program, the 2007 EQC evaluations from 10 international sites showed a mean day 2 thawed viability of 83.1% and recovery of 67.5%. Since then, four year cumulative data covering 3338 specimens used in immunologic assays shows that 99.88% had acceptable viabilities (>66%) for use in cellular assays (mean, 91.46% ±4.5%), and 96.2% had acceptable recoveries (50%–130%) with a mean of recovery of 85.8% ±19.12% of the originally cryopreserved cells. EQC testing revealed that since August 2009, failed recoveries dropped from 4.1% to 1.6% and failed viabilities dropped from 1.0% to 0.3%. The HVTN PBMC quality program provides for laboratory assessment, training and tools for identifying problems, implementing corrective action and monitoring for improvements. These data support the benefits of implementing a comprehensive, web-based PBMC quality program for large clinical trials networks. PMID:24709391
Mezzenga, Emilio; D'Errico, Vincenzo; Sarnelli, Anna; Strigari, Lidia; Menghi, Enrico; Marcocci, Francesco; Bianchini, David; Benassi, Marcello
2016-01-01
The purpose of this study was to retrospectively evaluate the results from a Helical TomoTherapy Hi-Art treatment system relating to quality controls based on daily static and dynamic output checks using statistical process control methods. Individual value X-charts, exponentially weighted moving average charts, and process capability and acceptability indices were used to monitor the treatment system performance. Daily output values measured from January 2014 to January 2015 were considered. The results obtained showed that, although the process was in control, there was an out-of-control situation in the principal maintenance intervention for the treatment system. In particular, process capability indices showed a decreasing percentage of points in control which was, however, acceptable according to AAPM TG148 guidelines. Our findings underline the importance of restricting the acceptable range of daily output checks and suggest a future line of investigation for a detailed process control of daily output checks for the Helical TomoTherapy Hi-Art treatment system.
Balderson, Benjamin H; McCurry, Susan M; Vitiello, Michael V; Shortreed, Susan M; Rybarczyk, Bruce D; Keefe, Francis J; Korff, Michael Von
2016-01-01
This article considers methodology for developing an education-only control group and proposes a simple approach to designing rigorous and well-accepted control groups. This approach is demonstrated in a large randomized trial. The Lifestyles trial (n = 367) compared three group interventions: (a) cognitive-behavioral treatment (CBT) for osteoarthritis pain, (b) CBT for osteoarthritis pain and insomnia, and (c) education-only control (EOC). EOC emulated the interventions excluding hypothesized treatment components and controlling for nonspecific treatment effects. Results showed this approach resulted in a control group that was highly credible and acceptable to patients. This approach can be an effective and practical guide for developing high-quality control groups in trials of behavioral interventions.
Effect of wheat bran and dried carrot pomace addition on quality characteristics of chicken sausage
2018-01-01
Objective Effect of addition of wheat bran (WB) and dried carrot pomace (DCP) on sensory, textural, colour, physico-chemical and nutritional characteristics of chicken sausage were evaluated. Methods WB and DCP were used as a source of dietary fibre at 3%, 6%, and 9% level individually. Different quality attributes of sausages were estimated. One product from each source with very good sensory acceptability was selected to analyze dietary fibre content and shelf life under refrigerated storage. Results Sensory acceptability of 3% fibre enriched sausage was comparable with control and a further increase in fibre level resulted in a decrease in sensory acceptability. Fibre enriched sausages were significantly harder and less cohesive than control sausage. Significant increase in gumminess and chewiness was observed at 6% level in WB treated sausages and 9% level in DCP treated sausages. Moisture content decreased significantly in all treated sausages, protein content decreased significantly in DCP-2 and DCP-3 sausages while fat content decreased in all WB and DCP-3 treated sausages in comparison to control. The fibre enriched sausage had significantly higher dietary fibre and lower cholesterol content. Cooking yield and emulsion stability increased in treated sausages and a significant difference was noticed at 6% level in both types of sausages. pH of WB treated sausages was significantly higher and DCP treated sausage significantly lower in comparison to control. Conclusion The results of present study indicate that fibre enriched chicken sausage with moderate acceptability can be developed by incorporating WB and DCP each up to 9% level. Chicken sausage with very good acceptability, higher dietary fibre content and storability up to 15 days at refrigerated temperature can be developed by incorporating WB and DCP at 6% level each. PMID:28823131
External quality assessment of national public health laboratories in Africa, 2002–2009
Perovic, Olga; Fensham, Vivian; McCarthy, Kerrigan; von Gottberg, Anne; de Gouveia, Linda; Poonsamy, Bhavani; Dini, Leigh; Rossouw, Jenny; Keddy, Karen; Alemu, Wondimagegnehu; Yahaya, Ali; Pierson, Antoine; Dolmazon, Virginie; Cognat, Sébastien; Ndihokubwayo, Jean Bosco
2012-01-01
Abstract Objective To describe findings from an external quality assessment programme involving laboratories in Africa that routinely investigate epidemic-prone diseases. Methods Beginning in 2002, the Regional Office for Africa of the World Health Organization (WHO) invited national public health laboratories and related facilities in Africa to participate in the programme. Three surveys comprising specimens and questionnaires associated with bacterial enteric diseases, bacterial meningitis, plague, tuberculosis and malaria were sent annually to test participants’ diagnostic proficiency. Identical surveys were sent to referee laboratories for quality control. Materials were prepared, packaged and shipped in accordance with standard protocols. Findings and reports were due within 30 days. Key methodological decisions and test results were categorized as acceptable or unacceptable on the basis of consensus feedback from referees, using established grading schemes. Findings Between 2002 and 2009, participation increased from 30 to 48 Member States of the WHO and from 39 to 78 laboratories. Each survey was returned by 64–93% of participants. Mean turnaround time was 25.9 days. For bacterial enteric diseases and meningitis components, bacterial identification was acceptable in 65% and 69% of challenges, respectively, but serotyping and antibiotic susceptibility testing and reporting were frequently unacceptable. Microscopy was acceptable for 73% of plague challenges. Tuberculosis microscopy was satisfactorily performed, with 87% of responses receiving acceptable scores. In the malaria component, 82% of responses received acceptable scores for species identification but only 51% of parasite quantitation scores were acceptable. Conclusion The external quality assessment programme consistently identified certain functional deficiencies requiring strengthening that were present in African public health microbiology laboratories. PMID:22461714
Glenton, Claire; Khanna, Rajesh; Morgan, Chris; Nilsen, Elin Strømme
2013-08-01
To systematically assess (i) the effects and safety and (ii) the acceptability of using lay health workers (LHWs) to deliver vaccines and medicines to mothers and children through compact pre-filled autodisable devices (CPADs). We searched electronic databases and grey literature. For the systematic review of effects and safety, we sought randomised and non-randomised controlled trials, controlled before-after studies and interrupted time series studies. For the systematic review of acceptability, we sought qualitative studies. Two researchers independently carried out data extraction, study quality assessment and thematic analysis of the qualitative data. No studies met our criteria for the review exploring the effects and safety of using LHWs to deliver CPADs. For the acceptability review, six qualitative studies assessed the acceptability of using LHWs to deliver hepatitis B vaccine, tetanus toxoid vaccine, gentamicin or oxytocin using Uniject™ devices. All studies took place in low- or middle-income countries and explored the perceptions of community members, LHWs, supervisors, health professionals or programme managers. Most of the studies were of low quality. Recipients generally accepted the intervention. Most health professionals were confident that LHWs could deliver the intervention with sufficient training and supervision, but some had problems delivering supervision. The LHWs perceived Uniject™ as effective and important and were motivated by positive responses from the community. However, some LHWs feared the consequences if harm should come to recipients. Evidence of the effects and safety of using CPADs delivered by LHWs is lacking. Evidence regarding acceptability suggests that this intervention may be acceptable although LHWs may feel vulnerable to blame. © 2013 John Wiley & Sons Ltd.
Maintaining Acceptable Indoor Air Quality during the Renovation of a School. Technical Bulletin.
ERIC Educational Resources Information Center
Jacobs, Bruce W.
Information that school facility personnel can use concerning the potential impacts of renovation projects on indoor air quality (IAQ), along with details of some effective control strategies, are presented. Various kinds of contaminants may be generated by renovations, including volatile and semivolatile organic compounds, dusts and fibers (e.g.,…
Internal quality assurance in a clinical virology laboratory. II. Internal quality control.
Gray, J J; Wreghitt, T G; McKee, T A; McIntyre, P; Roth, C E; Smith, D J; Sutehall, G; Higgins, G; Geraghty, R; Whetstone, R
1995-01-01
AIMS--In April 1991 additional quality control procedures were introduced into the virology section of the Clinical Microbiology and Public Health Laboratory, Cambridge. Internal quality control (IQC) samples were gradually included in the serological assays performed in the laboratory and supplemented kit controls and standard sera. METHODS--From April 1991 to December 1993, 2421 IQC procedures were carried out with reference sera. RESULTS--The IQC samples were evaluated according to the Westgard rules. Violations were recorded in 60 of 1808 (3.3%) controls and were highest in the IQC samples of complement fixation tests (25/312 (8%) of controls submitted for complement fixation tests). CONCLUSIONS--The inclusion of IQC samples in the serological assays performed in the laboratory has highlighted batch to batch variation in commercial assays. The setting of acceptable limits for the IQC samples has increased confidence in the validity of assay results. PMID:7730475
Molander, Peter; Hesser, Hugo; Weineland, Sandra; Bergwall, Kajsa; Buck, Sonia; Hansson-Malmlöf, Johan; Lantz, Henning; Lunner, Thomas; Andersson, Gerhard
2015-09-01
Psychological distress and psychiatric symptoms are prevalent among people with hearing loss or other audiological conditions, but psychological interventions for these groups are rare. This article describes the study protocol for a randomized controlled trial for evaluating the effect of a psychological treatment delivered over the Internet for individuals with hearing problems and concurrent psychological distress. Participants who are significantly distressed will be randomized to either an 8-week Internet-delivered acceptance-based cognitive behavioral therapy (i.e., acceptance and commitment therapy [ACT]), or wa it-list control. We aim to include measures of distress associated with hearing difficulties, anxiety, and depression. In addition, we aim to measure acceptance associated with hearing difficulties as well as quality of life. The results of the trial may further our understanding of how to best treat people who present problems with both psychological distress and hearing in using the Internet.
NASA Technical Reports Server (NTRS)
Feather, J. B.; Joshi, D. S.
1981-01-01
Handling qualities of the unaugmented advanced supersonic transport (AST) are deficient in the low-speed, landing approach regime. Consequently, improvement in handling with active control augmentation systems has been achieved using implicit model-following techniques. Extensive fixed-based simulator evaluations were used to validate these systems prior to tests with full motion and visual capabilities on a six-axis motion-base simulator (MBS). These tests compared the handling qualities of the unaugmented AST with several augmented configurations to ascertain the effectiveness of these systems. Cooper-Harper ratings, tracking errors, and control activity data from the MBS tests have been analyzed statistically. The results show the fully augmented AST handling qualities have been improved to an acceptable level.
Paolantonacci, Philippe; Appourchaux, Philippe; Claudel, Béatrice; Ollivier, Monique; Dennett, Richard; Siret, Laurent
2018-01-01
Polyvalent human normal immunoglobulins for intravenous use (IVIg), indicated for rare and often severe diseases, are complex plasma-derived protein preparations. A quality by design approach has been used to develop the Laboratoire Français du Fractionnement et des Biotechnologies new-generation IVIg, targeting a high level of purity to generate an enhanced safety profile while maintaining a high level of efficacy. A modular approach of quality by design was implemented consisting of five consecutive steps to cover all the stages from the product design to the final product control strategy.A well-defined target product profile was translated into 27 product quality attributes that formed the basis of the process design. In parallel, a product risk analysis was conducted and identified 19 critical quality attributes among the product quality attributes. Process risk analysis was carried out to establish the links between process parameters and critical quality attributes. Twelve critical steps were identified, and for each of these steps a risk mitigation plan was established.Among the different process risk mitigation exercises, five process robustness studies were conducted at qualified small scale with a design of experiment approach. For each process step, critical process parameters were identified and, for each critical process parameter, proven acceptable ranges were established. The quality risk management and risk mitigation outputs, including verification of proven acceptable ranges, were used to design the process verification exercise at industrial scale.Finally, the control strategy was established using a mix, or hybrid, of the traditional approach plus elements of the quality by design enhanced approach, as illustrated, to more robustly assign material and process controls and in order to securely meet product specifications.The advantages of this quality by design approach were improved process knowledge for industrial design and process validation and a clear justification of the process and product specifications as a basis for control strategy and future comparability exercises. © PDA, Inc. 2018.
Taking advantage of ground data systems attributes to achieve quality results in testing software
NASA Technical Reports Server (NTRS)
Sigman, Clayton B.; Koslosky, John T.; Hageman, Barbara H.
1994-01-01
During the software development life cycle process, basic testing starts with the development team. At the end of the development process, an acceptance test is performed for the user to ensure that the deliverable is acceptable. Ideally, the delivery is an operational product with zero defects. However, the goal of zero defects is normally not achieved but is successful to various degrees. With the emphasis on building low cost ground support systems while maintaining a quality product, a key element in the test process is simulator capability. This paper reviews the Transportable Payload Operations Control Center (TPOCC) Advanced Spacecraft Simulator (TASS) test tool that is used in the acceptance test process for unmanned satellite operations control centers. The TASS is designed to support the development, test and operational environments of the Goddard Space Flight Center (GSFC) operations control centers. The TASS uses the same basic architecture as the operations control center. This architecture is characterized by its use of distributed processing, industry standards, commercial off-the-shelf (COTS) hardware and software components, and reusable software. The TASS uses much of the same TPOCC architecture and reusable software that the operations control center developer uses. The TASS also makes use of reusable simulator software in the mission specific versions of the TASS. Very little new software needs to be developed, mainly mission specific telemetry communication and command processing software. By taking advantage of the ground data system attributes, successful software reuse for operational systems provides the opportunity to extend the reuse concept into the test area. Consistency in test approach is a major step in achieving quality results.
USAF Test Pilot School. Flying Qualities Textbook, Volume 2, Part 1
1986-04-01
Qualities Flight Testing, Performance and Flying Qaulities Branch, Flight Test Engneerd ision, 6510th Test Wing, Air Force Flight Mayst Ce1ter, Edwards...For these aircraft, the program manager may re*uire a mil spec written specifically for the aircraft and control system involwd. 5.20.2 _EL k,Tt...OR MANAGED IN CONTEXT OF MISSION, WITH AVAILABLE PILOT ATTENTION. S UNCONTROLLABLE CONTROL WILL BE LOST DURING SOME PORTION OF MISSION. ACCEPTABLE
Dynamics and controls in maglev systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, Y.; Chen, S.S.; Rote, D.M.
1992-09-01
The dynamic response of magnetically levitated (maglev) ground transportation systems has important consequences for safety and ride quality, guideway design, and system costs. Ride quality is determined by vehicle response and by environmental factors such as humidity and noise. The dynamic response of the vehicles is the key element in determining ride quality, and vehicle stability is an important safety-related element. To design a proper guideway that provides acceptable ride quality in the stable region, vehicle dynamics must be understood. Furthermore the trade-off between guideway smoothness and the levitation and control systems must be considered if maglev systems are tomore » be economically feasible. The link between the guideway and the other maglev components is vehicle dynamics. For a commercial maglev system, vehicle dynamics must be analyzed and tested in detail. In this study, the role of dynamics and controls in maglev vehicle/guideway interactions is discussed, and the literature on modeling the dynamic interactions of vehicle/guideway and suspension controls for ground vehicles is reviewed. Particular emphasis is placed on modeling vehicle/guideway interactions and response characteristics of maglev systems for a multicar, multiload vehicle traveling on a single- or doublespan flexible guideway, including coupling effects of vehicle/guideway, comparison of concentrated and distributed loads, and ride comfort. Different control-law designs are introduced into vehicle suspensions when a simple two-degree-of-freedom vehicle model is applied. Active and semiactive control designs for primary and secondary suspensions do improve the response of vehicle and provide acceptable ride comfort. Finally, future research associated with dynamics and controls of vehicle/guideway systems is identified.« less
Intimate relationship quality, self-concept and illness acceptance in those with multiple sclerosis.
Wright, Thomas M; Kiropoulos, Litza A
2017-02-01
Lower levels of Intimate Relationship Quality (IRQ) have been found in those with Multiple Sclerosis (MS) compared to the general population. This study examined an MS sample to see whether IRQ was positively associated with self-concept, whether IRQ was positively associated with MS illness acceptance and whether IRQ was predicted by self-concept and illness acceptance. In this cross-sectional study, 115 participants with MS who were in an intimate relationship completed an online survey advertised on MS related websites. The survey assessed demographic variables, MS illness variables and levels of IRQ, self-concept and illness acceptance. Results revealed that IRQ was significantly positively associated with self-concept and with illness acceptance. Multiple hierarchical linear regression analysis revealed that, after controlling for illness duration and level of disability, self-concept significantly predicted IRQ but illness acceptance did not significantly predict IRQ. This study addressed several gaps and methodological flaws in the literature and was the first known to assess predictors of IRQ in those with MS. The results suggest that self-concept could be a potential target for individual and couple psychological interventions to improve IRQ and contribute to improved outcomes for those with MS.
Storage influence on the functional, sensory and keeping quality of quality protein maize flour.
Shobha, D; Kumar, H V Dileep; Sreeramasetty, T A; Puttaramanaik; Gowda, K T Pandurange; Shivakumar, G B
2014-11-01
Apart from nutritional values functional and sensory properties affect the behavior of food system and its acceptability for consumption during storage. Hence keeping quality of maize flour (HQPM-7) with and without lime treatment(control) was studied in terms of functional (bulk density, pH, swelling capacity, water and oil absorption capacity, least gelation concentration, peroxide value), sensory (appearance, color, taste, texture, mouth feel and overall acceptability) and rolling parameters (water absorption by flour, rolling quality, diameter after baking ) for a period of 6 months under room temperature (25 ± 5 °C) in two types of packages viz, LDPE cover (P) and plastic box (B). Physical parameters such as length, breadth and thickness (11.26-10.52 mm, 9.67-9.14 mm, & 4.72-3.95 mm) were reduced in lime treated grains compared to control. Significant increase (p ≤ 0.05) in ash content of lime treated flour (1.67 ± 0.01 g) was observed compared to control (1.5 ± 0.02 g). Calcium content of lime treated maize flour increased significantly (p ≤ 0.05) from 48 to 136 mg. There is a significant reduction in functional properties of flour after 3 and 2 months irrespective in polyethylene cover and plastic box. The properties like rolling quality, diameter after baking and water uptake by the flour were reduced significantly (p ≤ 0.05) after 4 months of storage in treated and after 1 month in control samples. Sensory scores of roti (dry pan cake) decreased significantly after 3 months of storage with an overall acceptability score of 4.0 and 3.4. In control samples mean taste (3.6), mouth feel (3.8) as well as OAA scores (3.8) decreased after second month. Hence lime treated maize flour with added nutritional benefits is suitable for making rotis of good palatability and can be stored in LDPE covers up to 3 months.
DOT National Transportation Integrated Search
1975-12-01
The primary objective of this study was to review the data generated by projects governed by statistically oriented system of specifications for the control and acceptance of asphaltic concrete and to recommend any revisions that may be deemed necess...
Code of Federal Regulations, 2011 CFR
2011-01-01
... agrees to apply his or her water-quality plan. Any person who controls, or shares control, of the farm... AGRICULTURE LONG TERM CONTRACTING RURAL CLEAN WATER PROGRAM Participant RCWP Contracts § 634.25 Contracting... of the farm, ranch, or other land. The administering agency is to determine the acceptability of the...
PACS: acceptance test, quality control, warranty, and maintenance continuum
NASA Astrophysics Data System (ADS)
Romlein, John R.; Norton, Gary S.; Lyche, David K.; Richardson, Ronald R., Jr.
1999-07-01
As PACS gain greater acceptance and use in medical facilities the question of life cycle management must be addressed in terms that relate to the common business practices for medical information system and medical devices. The issues in life cycle management of such a system are relatively new to the industry. Increased use of PACS within the medical community requires that standardized life cycle management practices by developed and implemented. This paper develops a new of life cycle issues as cyclic and related events that are not only manageable, but also predictable in terms, of, frequency, duration data content, data exchange, potential outcomes, staffing requirement, documentation, and staff interaction. This view is presented as a continuum that begins at the acceptance testing of a PACS and continues throughout its life cycle. The continuum incorporates the required relationship between quality control testing and maintenance actions during warranty period and the maintenance years. Interrelated cyclic events are described that bind these processes together and provide a basis for long-term proactive management of PACS in a medical environment.
Dozier, Samantha; Brown, Jeffrey; Currie, Alistair
2011-11-29
In recent years, technologically advanced high-throughput techniques have been developed that replace, reduce or refine animal use in vaccine quality control tests. Following validation, these tests are slowly being accepted for use by international regulatory authorities. Because regulatory acceptance itself has not guaranteed that approved humane methods are adopted by manufacturers, various organizations have sought to foster the preferential use of validated non-animal methods by interfacing with industry and regulatory authorities. After noticing this gap between regulation and uptake by industry, we began developing a paradigm that seeks to narrow the gap and quicken implementation of new replacement, refinement or reduction guidance. A systematic analysis of our experience in promoting the transparent implementation of validated non-animal vaccine potency assays has led to the refinement of our paradigmatic process, presented here, by which interested parties can assess the local regulatory acceptance of methods that reduce animal use and integrate them into quality control testing protocols, or ensure the elimination of peripheral barriers to their use, particularly for potency and other tests carried out on production batches.
Kaisey, Marwa; Mittman, Brian; Pearson, Marjorie; Connor, Karen I; Chodosh, Joshua; Vassar, Stefanie D; Nguyen, France T; Vickrey, Barbara G
2012-10-01
Care management approaches have been proven to improve outcomes for patients with dementia and their family caregivers (dyads). However, acceptance of services in these programs is incomplete, impacting effectiveness. Acceptance may be related to dyad as well as healthcare system characteristics, but knowledge about factors associated with program acceptance is lacking. This study investigates patient, caregiver, and healthcare system characteristics associated with acceptance of offered care management services. This study analyzed data from the intervention arm of a cluster randomized controlled trial of a comprehensive dementia care management intervention. There were 408 patient-caregiver dyads enrolled in the study, of which 238 dyads were randomized to the intervention. Caregiver, patient, and health system factors associated with participation in offered care management services were assessed through bivariate and multivariate regression analyses. Out of the 238 dyads, 9 were ineligible for this analysis, leaving data of 229 dyads in this sample. Of these, 185 dyads accepted offered care management services, and 44 dyads did not. Multivariate analyses showed that higher likelihood of acceptance of care management services was uniquely associated with cohabitation of caregiver and patient (p < 0.001), lesser severity of dementia (p = 0.03), and higher patient comorbidity (p = 0.03); it also varied across healthcare organization sites. Understanding factors that influence care management participation could result in increased adoption of successful programs to improve quality of care. Using these factors to revise both program design as well as program promotion may also benefit external validity of future quality improvement research trials. Copyright © 2011 John Wiley & Sons, Ltd.
Gattrell, William T; Hopewell, Sally; Young, Kate; Farrow, Paul; White, Richard; Winchester, Christopher C
2016-01-01
Objectives Authors may choose to work with professional medical writers when writing up their research for publication. We examined the relationship between medical writing support and the quality and timeliness of reporting of the results of randomised controlled trials (RCTs). Design Cross-sectional study. Study sample Primary reports of RCTs published in BioMed Central journals from 2000 to 16 July 2014, subdivided into those with medical writing support (n=110) and those without medical writing support (n=123). Main outcome measures Proportion of items that were completely reported from a predefined subset of the Consolidated Standards of Reporting Trials (CONSORT) checklist (12 items known to be commonly poorly reported), overall acceptance time (from manuscript submission to editorial acceptance) and quality of written English as assessed by peer reviewers. The effect of funding source and publication year was examined. Results The number of articles that completely reported at least 50% of the CONSORT items assessed was higher for those with declared medical writing support (39.1% (43/110 articles); 95% CI 29.9% to 48.9%) than for those without (21.1% (26/123 articles); 95% CI 14.3% to 29.4%). Articles with declared medical writing support were more likely than articles without such support to have acceptable written English (81.1% (43/53 articles); 95% CI 67.6% to 90.1% vs 47.9% (23/48 articles); 95% CI 33.5% to 62.7%). The median time of overall acceptance was longer for articles with declared medical writing support than for those without (167 days (IQR 114.5–231 days) vs 136 days (IQR 77–193 days)). Conclusions In this sample of open-access journals, declared professional medical writing support was associated with more complete reporting of clinical trial results and higher quality of written English. Medical writing support may play an important role in raising the quality of clinical trial reporting. PMID:26899254
Ciaramella, Michael A; Kim, Taejo; Avery, Jimmy L; Allen, Peter J; Schilling, M Wes
2016-08-01
Stress during fish culture alters physiological homeostasis and affects fillet quality. Maintenance of high-quality seafood is important to ensure the production of a marketable product. This study assessed how sequential stressors affect the sensory and quality characteristics of catfish (Ictalurus punctatus) fillets. Three stress trials were conducted where temperature (25 or 33 °C) and dissolved oxygen (DO, approximately 2.5 or >5 mg/L) were manipulated followed by socking and transport stress. After each stage of harvest (environmental stress, socking, and transport), fillet yield, consumer acceptability, descriptive evaluation, cook loss, tenderness, and pH were evaluated. Fillet yield decreased with increasing severity of environmental stress. Fillets from the severe stress treatment (33 °C, approximately 2.5 mg/L) received the highest acceptability scores (P < 0.05). Control fillets (25 °C, >5 mg/L) were the least acceptable (P < 0.05). Increased intensity of less favorable flavor attributes commonly associated with catfish resulted in the differences in acceptability among treatments. As fish progressed through the harvest event, cook loss decreased, tenderness increased, and pH increased, indicating that stress induced textural changes. The data suggest that although environmental stress results in slight changes in flavor attributes, its effects on acceptability are minor with fillets from all treatments still liked (>6 on a 9 point scale). Socking and transport were identified to positively affect textural characteristics of catfish fillets. Although the effects observed were not likely to negatively impact consumer acceptance, a strict management plan should be followed to maintain consistency in the product and avoid changes in stressors that might alter quality more drastically. © 2016 Institute of Food Technologists®
Ducar, Constance; Smith, Donna; Pinzon, Cris; Stirewalt, Michael; Cooper, Cristine; McElrath, M Juliana; Hural, John
2014-07-01
The HIV Vaccine Trials Network (HVTN) is a global network of 28 clinical trial sites dedicated to identifying an effective HIV vaccine. Cryopreservation of high-quality peripheral blood mononuclear cells (PBMC) is critical for the assessment of vaccine-induced cellular immune functions. The HVTN PBMC Quality Management Program is designed to ensure that viable PBMC are processed, stored and shipped for clinical trial assays from all HVTN clinical trial sites. The program has evolved by developing and incorporating best practices for laboratory and specimen quality and implementing automated, web-based tools. These tools allow the site-affiliated processing laboratories and the central Laboratory Operations Unit to rapidly collect, analyze and report PBMC quality data. The HVTN PBMC Quality Management Program includes five key components: 1) Laboratory Assessment, 2) PBMC Training and Certification, 3) Internal Quality Control, 4) External Quality Control (EQC), and 5) Assay Specimen Quality Control. Fresh PBMC processing data is uploaded from each clinical site processing laboratory to a central HVTN Statistical and Data Management Center database for access and analysis on a web portal. Samples are thawed at a central laboratory for assay or specimen quality control and sample quality data is uploaded directly to the database by the central laboratory. Four year cumulative data covering 23,477 blood draws reveals an average fresh PBMC yield of 1.45×10(6)±0.48 cells per milliliter of useable whole blood. 95% of samples were within the acceptable range for fresh cell yield of 0.8-3.2×10(6) cells/ml of usable blood. Prior to full implementation of the HVTN PBMC Quality Management Program, the 2007 EQC evaluations from 10 international sites showed a mean day 2 thawed viability of 83.1% and a recovery of 67.5%. Since then, four year cumulative data covering 3338 specimens used in immunologic assays shows that 99.88% had acceptable viabilities (>66%) for use in cellular assays (mean, 91.46% ±4.5%), and 96.2% had acceptable recoveries (50%-130%) with a mean of recovery of 85.8% ±19.12% of the originally cryopreserved cells. EQC testing revealed that since August 2009, failed recoveries dropped from 4.1% to 1.6% and failed viabilities dropped from 1.0% to 0.3%. The HVTN PBMC quality program provides for laboratory assessment, training and tools for identifying problems, implementing corrective action and monitoring for improvements. These data support the benefits of implementing a comprehensive, web-based PBMC quality program for large clinical trials networks. Copyright © 2014 Elsevier B.V. All rights reserved.
Ayaki, Masahiko; Hattori, Atsuhiko; Maruyama, Yusuke; Nakano, Masaki; Yoshimura, Michitaka; Kitazawa, Momoko; Negishi, Kazuno; Tsubota, Kazuo
2016-01-01
We investigated sleep quality and melatonin in 12 adults who wore blue-light shield or control eyewear 2 hours before sleep while using a self-luminous portable device, and assessed visual quality for the two eyewear types. Overnight melatonin secretion was significantly higher after using the blue-light shield (P < 0.05) than with the control eyewear. Sleep efficacy and sleep latency were significantly superior for wearers of the blue-light shield (P < 0.05 for both), and this group reported greater sleepiness during portable device use compared to those using the control eyewear. Participants rated the blue-light shield as providing acceptable visual quality.
Design criteria monograph on turbopump gears
NASA Technical Reports Server (NTRS)
1975-01-01
Turbopump power gears were brought to acceptable levels of usefulness and reliability through refinements in interdependent areas of design, materials, processing, and quality control combined with extensive development testing that explored problem areas and evaluated potential solutions.
Koutsimanis, Georgios; Harte, Janice; Almenar, Eva
2015-03-30
Current consumer demand for high-quality ready-to-eat fresh fruit in convenient bio-based packaging was met utilizing sanitized stem-free sweet cherries and a polylactic acid (PLA) cup with a PLA peelable microperforated lid. The newly developed packaging system was compared with the petroleum-based macroperforated bag currently used for retail. After 27 days of storage at 1 °C, the PLA package maintained the cherry firmness, compared with a 50% reduction of the controls. No fungal decay was detected in the cherries stored in PLA, while the controls were non-marketable after 21 days. The PLA package allowed minimal weight loss (0.8%), compared with a weight loss of approximately 16% in the controls. Differences in the cherry aroma, color, acidity, soluble solids content, pH and quality index were also caused by the packaging type. A consumer sensory evaluation showed that cherries stored in PLA packages were more acceptable than those of the controls for appearance, texture, flavor and overall acceptability. The new package matched both the consumer demand for high-quality fresh fruit ready for consumption in convenient bio-based packaging and the extended fruit marketability and consumer satisfaction desired by industry. © 2014 Society of Chemical Industry.
Imm, Bue-Young; Kim, Chung Hwan; Imm, Jee-Young
2014-01-01
Korean traditional meat patties (Tteokgalbi) were prepared by replacing part of the lean meat content with either pork backfat or canola oil and the effect of substitution on sensory quality of the meat patties was investigated. Compared to the control patties, pork-loin Tteokgalbi with 10% pork backfat or 10% canola oil had significantly higher overall acceptability and higher perceived intensity of meat flavor, sweetness, umami, and oiliness. The pork-loin patties containing 10% fat also had lower perceived firmness, toughness, and chalkiness of than the control Tteokgalbi. The chicken breast Tteokgalbi with 10% canola oil had the lowest perceived firmness and chalkiness (control > pork backfat > canola oil). No significant difference was noted in the overall acceptability of chicken breast patties with 10% pork backfat and those with 10% canola oil. These results indicate that substituting 10% of lean meat of Tteokgalbi with fat improved the sensory acceptability of the product for Korean customers regardless of the lean meat and/or fat source used in the patties. Lean meat patties formulated with a limited amount of vegetable oil such as canola oil can be a healthy option for Korean consumers by providing desirable fatty acid profiles without sacrificing sensory quality of the product. PMID:26761287
Imm, Bue-Young; Kim, Chung Hwan; Imm, Jee-Young
2014-01-01
Korean traditional meat patties (Tteokgalbi) were prepared by replacing part of the lean meat content with either pork backfat or canola oil and the effect of substitution on sensory quality of the meat patties was investigated. Compared to the control patties, pork-loin Tteokgalbi with 10% pork backfat or 10% canola oil had significantly higher overall acceptability and higher perceived intensity of meat flavor, sweetness, umami, and oiliness. The pork-loin patties containing 10% fat also had lower perceived firmness, toughness, and chalkiness of than the control Tteokgalbi. The chicken breast Tteokgalbi with 10% canola oil had the lowest perceived firmness and chalkiness (control > pork backfat > canola oil). No significant difference was noted in the overall acceptability of chicken breast patties with 10% pork backfat and those with 10% canola oil. These results indicate that substituting 10% of lean meat of Tteokgalbi with fat improved the sensory acceptability of the product for Korean customers regardless of the lean meat and/or fat source used in the patties. Lean meat patties formulated with a limited amount of vegetable oil such as canola oil can be a healthy option for Korean consumers by providing desirable fatty acid profiles without sacrificing sensory quality of the product.
The Ratios of Pre-emulsified Duck Skin for Optimized Processing of Restructured Ham.
Shim, Jae-Yun; Kim, Tae-Kyung; Kim, Young-Boong; Jeon, Ki-Hong; Ahn, Kwang-Il; Paik, Hyun-Dong; Choi, Yun-Sang
2018-02-01
The purpose of this study was to investigate the quality of duck ham formulated with duck skin through the pre-emulsification process. The experiments to investigate the quality characteristics of duck ham were carried out to measure proximate composition, cooking loss, emulsion stability, pH, color, texture profile analysis, apparent viscosity, and sensory characteristics. Duck ham was prepared with various ratios of duck skin in pre-emulsion as follows: Control (duct skin 30%), T1 (duck skin 20% + pre-emulsified duck skin 10%), T2 (duck skin 15% + pre-emulsified duck skin 15%), T3 (duck skin 10% + pre-emulsified duck skin 20%), and T4 (pre-emulsified duck skin 30%). As the ratio of duck skin to pre-emulsified skin changed, the quality of duck ham in terms of moisture content, fat content, cooking loss, emulsion stability, lightness, textural analysis, apparent viscosity, and overall acceptability changed. The moisture content of T2 was the highest ( p <0.05) and that of the control and T4 was the lowest ( p <0.05). The fat content of control was higher than all treatments ( p <0.05). T2 had the lowest values in cooking loss, total expressible fluid, fat separation, hardness, springiness, and gumminess ( p <0.05). The score of overall acceptability of all treatments with pre-emulsified skin was higher than control ( p <0.05). Therefore, the pre-emulsification process can improve the quality characteristics of duck ham and 1:1 ratio of duck skin and pre-emulsified skin was the proper ratio to improve the quality characteristics of duck ham.
Frost, Rachael; Levati, Sara; McClurg, Doreen; Brady, Marian; Williams, Brian
2017-06-01
To systematically review methods for measuring adherence used in home-based rehabilitation trials and to evaluate their validity, reliability, and acceptability. In phase 1 we searched the CENTRAL database, NHS Economic Evaluation Database, and Health Technology Assessment Database (January 2000 to April 2013) to identify adherence measures used in randomized controlled trials of allied health professional home-based rehabilitation interventions. In phase 2 we searched the databases of MEDLINE, Embase, CINAHL, Allied and Complementary Medicine Database, PsycINFO, CENTRAL, ProQuest Nursing and Allied Health, and Web of Science (inception to April 2015) for measurement property assessments for each measure. Studies assessing the validity, reliability, or acceptability of adherence measures. Two reviewers independently extracted data on participant and measure characteristics, measurement properties evaluated, evaluation methods, and outcome statistics and assessed study quality using the COnsensus-based Standards for the selection of health Measurement INstruments checklist. In phase 1 we included 8 adherence measures (56 trials). In phase 2, from the 222 measurement property assessments identified in 109 studies, 22 high-quality measurement property assessments were narratively synthesized. Low-quality studies were used as supporting data. StepWatch Activity Monitor validly and acceptably measured short-term step count adherence. The Problematic Experiences of Therapy Scale validly and reliably assessed adherence to vestibular rehabilitation exercises. Adherence diaries had moderately high validity and acceptability across limited populations. The Borg 6 to 20 scale, Bassett and Prapavessis scale, and Yamax CW series had insufficient validity. Low-quality evidence supported use of the Joint Protection Behaviour Assessment. Polar A1 series heart monitors were considered acceptable by 1 study. Current rehabilitation adherence measures are limited. Some possess promising validity and acceptability for certain parameters of adherence, situations, and populations and should be used in these situations. Rigorous evaluation of adherence measures in a broader range of populations is needed. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-13
... methods and definitions. The most significant problem with the prior version is the definition of... submitted to EPA a new Rule 3745-21-25 ``Control of VOC emissions from reinforced plastic composites... acceptable because Ohio has adopted OAC 3745-21- 25 for Reinforced Plastics Composites Production Operations...
NASA Technical Reports Server (NTRS)
Grantham, W. D.; Nguyen, L. T.; Deal, P. L.; Neubauer, M. J.; Smith, P. M.; Gregory, F. D.
1978-01-01
Conventional and powered lift concepts for supersonic approach and landing tasks are considered. Results indicated that the transport concepts had unacceptable low-speed handling qualities with no augmentation, and that in order to achieve satisfactory handling qualities, considerable augmentation was required. The available roll-control power was acceptable for the powered-lift concept.
Apter, Andrea J.; Wan, Fei; Reisine, Susan; Bogen, Daniel K.; Rand, Cynthia; Bender, Bruce; Bennett, Ian M.; Gonzalez, Rodalyn; Priolo, Chantel; Sonnad, Seema S.; Bryant-Stephens, Tyra; Ferguson, Monica; Boyd, Rhonda C.; Have, Thomas Ten; Roy, Jason
2014-01-01
Background Asthmatic adults from low-income urban neighborhoods have inferior health outcomes which in part may be due to barriers accessing care and with patient-provider communication. We adapted a patient advocate (PA) intervention to overcome these barriers. Objective To conduct a pilot study to assess feasibility, acceptability, and preliminary evidence of effectiveness. Methods A prospective randomized design was employed with mixed methods evaluation. Adults with moderate or severe asthma were randomized to 16 weeks of PA or a minimal intervention (MI) comparison condition. The PA, a nonprofessional, modeled preparations for a medical visit, attended the visit, and confirmed understanding. The PA facilitated scheduling, obtaining insurance coverage, and overcoming barriers to implementing medical advice. Outcomes included electronically-monitored inhaled corticosteroid adherence, asthma control, quality of life, FEV1, ED visits, and hospitalizations. Mixed-effects models guided an intention-to-treat analysis. Results 100 adults participated: age 47±14 years, 75% female, 71% African American, 16% white, baseline FEV1 69% ± 18%, 36% experiencing hospitalizations and 56% ED visits for asthma in the prior year. Ninety-three subjects completed all visits; 36 of 53 PA-assigned had a PA visit. Adherence declined significantly in the control (p= 0.001) but not significantly in the PA group (p=.30). Both PA and MI groups demonstrated improved asthma control (p=0.01 in both) and quality of life (p=0.001, p=0.004). Hospitalizations and ED visits for asthma did not differ between groups. The observed changes over time tended to favor the PA group, but this study was underpowered to detect differences between groups. Conclusion The PA intervention was feasible and acceptable and demonstrated potential for improving asthma control and quality of life. PMID:23800333
Verma, Akhilesh K; Chatli, Manish Kumar; Kumar, Devendra; Kumar, Pavan; Mehta, Nitin
2015-02-01
The present study was conducted to investigate the efficacy of sweet potato powder (SPP) and water as a fat replacer in low-fat pork patties. Low-fat pork patties were developed by replacing the added fat with combinations of SPP and chilled water. Three different levels of SPP/chilled water viz. 0.5/9.5% (T-1), 1.0/9.0% (T-2), and 1.5/8.5% (T-3) were compared with a control containing 10% animal fat. The quality of low-fat pork patties was evaluated for physico-chemical (pH, emulsion stability, cooking yield, aw), proximate, instrumental colour and textural profile, and sensory attributes. The cooking yield and emulsion stability improved (p<0.05) in all treatments over the control and were highest in T-2. Instrumental texture profile attributes and hardness decreased, whereas cohesiveness increased compared with control, irrespective of SPP level. Dimensional parameters (% gain in height and % decrease in diameter) were better maintained during cooking in the low-fat product than control. The sensory quality attributes juiciness, texture and overall acceptability of T-2 and T-3 were (p<0.05) higher than control. Results concluded that low-fat pork patties with acceptable sensory attributes, improved cooking yield and textural attributes can be successfully developed with the incorporation of a combination of 1.0% SPP and 9.0% chilled water.
Verma, Akhilesh K.; Chatli, Manish Kumar; Kumar, Devendra; Kumar, Pavan; Mehta, Nitin
2015-01-01
The present study was conducted to investigate the efficacy of sweet potato powder (SPP) and water as a fat replacer in low-fat pork patties. Low-fat pork patties were developed by replacing the added fat with combinations of SPP and chilled water. Three different levels of SPP/chilled water viz. 0.5/9.5% (T-1), 1.0/9.0% (T-2), and 1.5/8.5% (T-3) were compared with a control containing 10% animal fat. The quality of low-fat pork patties was evaluated for physico-chemical (pH, emulsion stability, cooking yield, aw), proximate, instrumental colour and textural profile, and sensory attributes. The cooking yield and emulsion stability improved (p<0.05) in all treatments over the control and were highest in T-2. Instrumental texture profile attributes and hardness decreased, whereas cohesiveness increased compared with control, irrespective of SPP level. Dimensional parameters (% gain in height and % decrease in diameter) were better maintained during cooking in the low-fat product than control. The sensory quality attributes juiciness, texture and overall acceptability of T-2 and T-3 were (p<0.05) higher than control. Results concluded that low-fat pork patties with acceptable sensory attributes, improved cooking yield and textural attributes can be successfully developed with the incorporation of a combination of 1.0% SPP and 9.0% chilled water. PMID:25557822
King, Heather C; Spence, Dennis L; Hickey, Anita H; Sargent, Paul; Elesh, Ronald; Connelly, Cynthia D
2015-05-01
The purpose of this study was to examine the feasibility and acceptability of an auricular acupuncture (AA) insomnia regimen among Operation Iraqi Freedom and Operation Enduring Freedom veterans with post-traumatic stress disorder and sleep disturbance. Secondarily, this study examined the effect of an AA insomnia regimen on objective sleep times by wrist actigraphy, subjective sleep times by sleep diary, and sleep quality ratings utilizing the Pittsburg Sleep Quality Index. Veterans (n = 30) were randomized to receive a 3-week AA insomnia regimen. Veterans receiving the AA insomnia regimen reported it as a more acceptable treatment for sleep disturbance than subjects in the control group (AA group median = 5 vs. control group median = 3, p = 0.004). Significant differences between groups were found on the sleep quality and daytime dysfunction components of the Pittsburgh Sleep Quality Index (p = 0.003, p = 0.004). No other significant differences between groups were found for objective and subjective sleep measures. These results suggest that an AA insomnia regimen may improve sleep quality and daytime dysfunction among veterans with post-traumatic stress disorder. Future, large-scale, prospective clinical trials are needed to examine AA effects on sleep. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.
Preliminary study to develop standard acceptance tests for pervious concrete.
DOT National Transportation Integrated Search
2017-05-01
Pervious concrete pavements are permeable pavement systems that are desired for their role in stormwater management and runoff control. Increased popularity in pervious concrete pavement applications has raised the need for the development of quality...
Knobel, LeRoy L.; Tucker, Betty J.; Rousseau, Joseph P.
2008-01-01
Water-quality activities conducted by the staff of the U.S. Geological Survey (USGS) Idaho National Laboratory (INL) Project Office coincide with the USGS mission of appraising the quantity and quality of the Nation's water resources. The activities are conducted in cooperation with the U.S. Department of Energy's (DOE) Idaho Operations Office. Results of the water-quality investigations are presented in various USGS publications or in refereed scientific journals. The results of the studies are highly regarded, and they are used with confidence by researchers, regulatory and managerial agencies, and interested civic groups. In its broadest sense, quality assurance refers to doing the job right the first time. It includes the functions of planning for products, review and acceptance of the products, and an audit designed to evaluate the system that produces the products. Quality control and quality assurance differ in that quality control ensures that things are done correctly given the 'state-of-the-art' technology, and quality assurance ensures that quality control is maintained within specified limits.
A design procedure for the handling qualities optimization of the X-29A aircraft
NASA Technical Reports Server (NTRS)
Bosworth, John T.; Cox, Timothy H.
1989-01-01
A design technique for handling qualities improvement was developed for the X-29A aircraft. As with any new aircraft, the X-29A control law designers were presented with a relatively high degree of uncertainty in their mathematical models. The presence of uncertainties, and the high level of static instability of the X-29A caused the control law designers to stress stability and robustness over handling qualities. During flight test, the mathematical models of the vehicle were validated or corrected to match the vehicle dynamic behavior. The updated models were then used to fine tune the control system to provide fighter-like handling characteristics. A design methodology was developed which works within the existing control system architecture to provide improved handling qualities and acceptable stability with a minimum of cost in both implementation as well as software verification and validation.
Dagg, P J; Butler, R J; Murray, J G; Biddle, R R
2006-08-01
In light of the increasing consumer demand for safe, high-quality food and recent public health concerns about food-borne illness, governments and agricultural industries are under pressure to provide comprehensive food safety policies and programmes consistent with international best practice. Countries that export food commodities derived from livestock must meet both the requirements of the importing country and domestic standards. It is internationally accepted that end-product quality control, and similar methods aimed at ensuring food safety, cannot adequately ensure the safety of the final product. To achieve an acceptable level of food safety, governments and the agricultural industry must work collaboratively to provide quality assurance systems, based on sound risk management principles, throughout the food supply chain. Quality assurance systems on livestock farms, as in other parts of the food supply chain, should address food safety using hazard analysis critical control point principles. These systems should target areas including biosecurity, disease monitoring and reporting, feedstuff safety, the safe use of agricultural and veterinary chemicals, the control of potential food-borne pathogens and traceability. They should also be supported by accredited training programmes, which award certification on completion, and auditing programmes to ensure that both local and internationally recognised guidelines and standards continue to be met. This paper discusses the development of policies for on-farm food safety measures and their practical implementation in the context of quality assurance programmes, using the Australian beef industry as a case study.
Hussain, Husniza; Khalid, Norhayati Mustafa; Selamat, Rusidah; Wan Nazaimoon, Wan Mohamud
2013-09-01
The urinary iodine micromethod (UIMM) is a modification of the conventional method and its performance needs evaluation. UIMM performance was evaluated using the method validation and 2008 Iodine Deficiency Disorders survey data obtained from four urinary iodine (UI) laboratories. Method acceptability tests and Sigma quality metrics were determined using total allowable errors (TEas) set by two external quality assurance (EQA) providers. UIMM obeyed various method acceptability test criteria with some discrepancies at low concentrations. Method validation data calculated against the UI Quality Program (TUIQP) TEas showed that the Sigma metrics were at 2.75, 1.80, and 3.80 for 51±15.50 µg/L, 108±32.40 µg/L, and 149±38.60 µg/L UI, respectively. External quality control (EQC) data showed that the performance of the laboratories was within Sigma metrics of 0.85-1.12, 1.57-4.36, and 1.46-4.98 at 46.91±7.05 µg/L, 135.14±13.53 µg/L, and 238.58±17.90 µg/L, respectively. No laboratory showed a calculated total error (TEcalc)
Whittingham, Koa; Sanders, Matthew R; McKinlay, Lynne; Boyd, Roslyn N
2016-06-01
To examine the effects of Stepping Stones Triple P (SSTP) and Acceptance and Commitment Therapy (ACT) on child functioning, quality of life, and parental adjustment. 67 parents (97.0% mothers) of children (64.2% male; mean age 5.3 ± 3.0 years) with cerebral palsy participated in a randomized controlled trial with three groups: wait-list control, SSTP, and SSTP + ACT. This article details the secondary outcomes. In comparison with wait-list, the SSTP + ACT group showed increased functional performance and quality of life as well as decreased parental psychological symptoms. No differences were found for parental confidence. No differences were found between SSTP and wait-list or between SSTP and SSTP + ACT. ACT-integrated parenting intervention may be an effective way to target child functioning, quality of life, and parental adjustment. © The Author 2015. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Sap flow sensors: construction, quality control and comparison.
Davis, Tyler W; Kuo, Chen-Min; Liang, Xu; Yu, Pao-Shan
2012-01-01
This work provides a design for two types of sensors, based on the thermal dissipation and heat ratio methods of sap flow calculation, for moderate to large scale deployments for the purpose of monitoring tree transpiration. These designs include a procedure for making these sensors, a quality control method for the final products, and a complete list of components with vendors and pricing information. Both sensor designs were field tested alongside a commercial sap flow sensor to assess their performance and show the importance for quality controlling the sensor outputs. Results show that for roughly 2% of the cost of commercial sensors, self-made sap flow sensors can provide acceptable estimates of the sap flow measurements compared to the commercial sensors.
Development of rational pay factors based on concrete compressive strength data
DOT National Transportation Integrated Search
2008-06-01
This research project addresses the opportunity to contain the escalating costs of concrete materials in construction projects. Both statistical process control and rational acceptance criteria show that quality improvement and cost savings can be ac...
14 CFR 23.621 - Casting factors.
Code of Federal Regulations, 2013 CFR
2013-01-01
... either magnetic particle, penetrant or other approved equivalent non-destructive inspection method; or... percent approved non-destructive inspection. When an approved quality control procedure is established and an acceptable statistical analysis supports reduction, non-destructive inspection may be reduced from...
14 CFR 23.621 - Casting factors.
Code of Federal Regulations, 2012 CFR
2012-01-01
... either magnetic particle, penetrant or other approved equivalent non-destructive inspection method; or... percent approved non-destructive inspection. When an approved quality control procedure is established and an acceptable statistical analysis supports reduction, non-destructive inspection may be reduced from...
14 CFR 23.621 - Casting factors.
Code of Federal Regulations, 2014 CFR
2014-01-01
... either magnetic particle, penetrant or other approved equivalent non-destructive inspection method; or... percent approved non-destructive inspection. When an approved quality control procedure is established and an acceptable statistical analysis supports reduction, non-destructive inspection may be reduced from...
14 CFR 23.621 - Casting factors.
Code of Federal Regulations, 2010 CFR
2010-01-01
... either magnetic particle, penetrant or other approved equivalent non-destructive inspection method; or... percent approved non-destructive inspection. When an approved quality control procedure is established and an acceptable statistical analysis supports reduction, non-destructive inspection may be reduced from...
Guzek, Dominika; Głąbska, Dominika; Brodowska, Marta; Godziszewska, Jolanta; Górska-Horczyczak, Elżbieta; Pogorzelska, Ewelina; Wojtasik-Kalinowska, Iwona; Wierzbicka, Agnieszka
2017-12-01
New meat products tailored to consumer health should be characterised by reduced sodium, fat and cholesterol contents and other health-promoting benefits. However, the food sector's greatest challenge is allergen-free production. Consumers are not willing to compromise the sensory quality of meat products for health. The aim of the present study was to analyse the influence of the storage time on the physical properties and consumer acceptance of allergen-controlled, fat-reduced, salt-reduced pork-ostrich sausages. The study focused on pork-ostrich sausages produced in accordance with a new patented technology, which focused on eliminating cross-contamination on-line in the plant, eliminating cross-contamination after preparation, and eliminating spices with high allergy potential. The production was focused on reducing fat (by approximately 50%) and salt (by approximately 30%) levels. No changes in the texture parameters of the sausage were observed during storage time; however, some changes in colour were observed. There were no significant differences in sensory consumer acceptability of pork-ostrich sausage after 14 days of storage; thus, it may be stated that the instrumentally assessed differences in colour did not influence consumer acceptance. The applied fat and NaCl reduction in the pork-ostrich sausages contributed to high consumer ratings and was not correlated with saltiness acceptability. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Drinking Water Quality in Hospitals and Other Buildings ...
Drinking water quality entering large buildings is generally adequately controlled by the water utility, but localized problems may occur within building or “premise” plumbing. Particular concerns are loss of disinfectant residual and temperature variability, which may enhance pathogen activity and metallic corrosion. Disinfection systems are available to building managers and are being installed in a variety of commercial buildings (hospitals, hotels, office buildings.) Yet our understanding of such additional treatment and of how to monitor end water quality at these buildings is limited. This class lecture will discuss challenges in maintaining acceptable water quality in hospitals, schools and other buildings. To give a lecture to a class of graduate students (ENVE 6054: Physical/Chemical Processes for Water Quality Control) at the University of Cincinnati, by presenting past research projects.
Restaurant consumer acceptance of beef loin strip steaks tenderized with calcium chloride.
Hoover, L C; Cook, K D; Miller, M F; Huffman, K L; Wu, C K; Lansdell, J L; Ramsey, C B
1995-12-01
Beef strip loins from either the right or left side of 22 carcasses of Bos indicus-type steers were injected with 200 mM calcium chloride (CaCl2) solution at 5% (wt/wt) to determine its effect on tenderness and other selected quality traits of steaks. Loins from opposite sides of the carcasses were untreated and served as the control. The steaks were evaluated for tenderness, juiciness, flavor intensity, tenderness acceptability, and overall acceptability by 62 restaurant consumers over a 6-wk period. The CaCl2 injection improved (P < .05) tenderness and flavor intensity ratings by the restaurant consumers. Tenderness acceptability and overall acceptability were improved 23 and 17%, respectively, by the CaCl2 injection. Flavor was not compromised by the CaCl2 injection. The CaCl2-treated steaks were rated superior(P < .05) for flavor compared to the control steaks. Restaurant consumers preferred the beef loin strip steaks injected with 200 mM CaCl2 at 5% (wt/wt). The results of this study are interpreted to indicate that, from a restaurant consumer perspective, CaCl2 injection is an acceptable means of making beef a more consistently tender product.
Sohrabi, Mehdi; Parsi, Masoumeh; Sina, Sedigheh
2018-05-17
A diagnostic reference level is an advisory dose level set by a regulatory authority in a country as an efficient criterion for protection of patients from unwanted medical exposure. In computed tomography, the direct dose measurement and data collection methods are commonly applied for determination of diagnostic reference levels. Recently, a new quality-control-based dose survey method was proposed by the authors to simplify the diagnostic reference-level determination using a retrospective quality control database usually available at a regulatory authority in a country. In line with such a development, a prospective dual-purpose quality control dosimetry protocol is proposed for determination of diagnostic reference levels in a country, which can be simply applied by quality control service providers. This new proposed method was applied to five computed tomography scanners in Shiraz, Iran, and diagnostic reference levels for head, abdomen/pelvis, sinus, chest, and lumbar spine examinations were determined. The results were compared to those obtained by the data collection and quality-control-based dose survey methods, carried out in parallel in this study, and were found to agree well within approximately 6%. This is highly acceptable for quality-control-based methods according to International Atomic Energy Agency tolerance levels (±20%).
Van Damme, Stefaan; De Waegeneer, Annelies; Debruyne, Jan
2016-06-01
Goal regulation strategies such as flexible goal adjustment and acceptance are believed to be protective factors in persons with chronic illness, but research on their relative contributions to quality of life in multiple sclerosis (MS) is lacking. We aimed to test the idea that acceptance and flexible goal adjustment (in contrast to tenacious goal pursuit) may help preserve the quality of life in persons with MS. A sample of 117 patients with MS was recruited. They completed questionnaires measuring quality of life (physical functioning, psychological distress), acceptance, flexible goal adjustment, and tenacious goal pursuit. Acceptance significantly accounted for variance in all three indexes of quality of life, beyond the effects of demographic and illness characteristics. The role of goal regulation style was less clear. Flexible goal adjustment significantly accounted for psychological well-being only. Surprisingly, tenacious goal pursuit predicted better psychological functioning and less psychological distress. No support was found for the hypothesis that acceptance and flexible goal adjustment would moderate the relation between illness severity and quality of life. The findings suggest the potential importance of acceptance in understanding MS patients' quality of life, although its hypothesized protective function could not be confirmed. Further conceptual work on acceptance and goal regulation style is needed, as well as prospective work investigating their causal status.
Homma, Mieko; Ishikawa, Hirono; Kiuchi, Takahiro
2016-04-01
The aim of this study was to elucidate whether physicians' illness perceptions correlate with their frustration or resistance to accepting patients with fibromyalgia (FM). In this cross-sectional postal survey, questionnaires were sent to member physicians of the Japan College of Rheumatology and Japan Rheumatism Foundation. Measures collected included the Brief Illness Perception Questionnaire with Causal Attribution, the Illness Invalidation Inventory, and the Difficult Doctor-Patient Relationship Questionnaire (DDPRQ-10). Multiple logistic regression was performed to examine associations between the DDPRQ-10 and resistance to accepting patients with FM for treatment. We analyzed data from 233 physicians who had experience in consulting with patients with FM. Only 44.2 % answered that they wanted to accept additional patients with FM. Physicians' frustration was associated with difficulty controlling symptoms, patients' emotional responses, and causal attribution of FM to patient internal factors. Conversely, lower levels of frustration were associated with causal attributions to biological factors and uncontrollable external factors. However, the "difficult patient" perception did not correlate with resistance to accepting patients with FM. Difficulty controlling symptoms with treatment was the one factor common to both physicians' frustration and resistance to accepting patients with FM. Physicians may hesitate to accept patients with FM not because of the stigmatic image of the "difficult patient," but instead because of the difficulty in controlling the symptoms of FM. Thus, to improve the quality of consultation, physicians must continuously receive new information about the treatments and causes of FM.
Johnson, Ian; Hutchings, Matt; Benstead, Rachel; Thain, John; Whitehouse, Paul
2004-07-01
In the UK Direct Toxicity Assessment Programme, carried out in 1998-2000, a series of internationally recognised short-term toxicity test methods for algae, invertebrates and fishes, and rapid methods (ECLOX and Microtox) were used extensively. Abbreviated versions of conventional tests (algal growth inhibition tests, Daphnia magna immobilisation test and the oyster embryo-larval development test) were valuable for toxicity screening of effluent discharges and the identification of causes and sources of toxicity. Rapid methods based on chemiluminescence and bioluminescence were not generally useful in this programme, but may have a role where the rapid test has been shown to be an acceptable surrogate for a standardised test method. A range of quality assurance and control measures were identified. Requirements for quality control/assurance are most stringent when deriving data for characterising the toxic hazards of effluents and monitoring compliance against a toxicity reduction target. Lower quality control/assurance requirements can be applied to discharge screening and the identification of causes and sources of toxicity.
DOT National Transportation Integrated Search
1998-09-01
In 1971, the Louisiana Department of Transportation and Development initiated a statistically based specification system for asphaltic concrete using historically generated data. A Materials Test Data (MATT) reporting system was also started to archi...
Shaikh, M S; Moiz, B
2016-04-01
Around two-thirds of important clinical decisions about the management of patients are based on laboratory test results. Clinical laboratories are required to adopt quality control (QC) measures to ensure provision of accurate and precise results. Six sigma is a statistical tool, which provides opportunity to assess performance at the highest level of excellence. The purpose of this study was to assess performance of our hematological parameters on sigma scale in order to identify gaps and hence areas of improvement in patient care. Twelve analytes included in the study were hemoglobin (Hb), hematocrit (Hct), red blood cell count (RBC), mean corpuscular volume (MCV), red cell distribution width (RDW), total leukocyte count (TLC) with percentages of neutrophils (Neutr%) and lymphocytes (Lymph %), platelet count (Plt), mean platelet volume (MPV), prothrombin time (PT), and fibrinogen (Fbg). Internal quality control data and external quality assurance survey results were utilized for the calculation of sigma metrics for each analyte. Acceptable sigma value of ≥3 was obtained for the majority of the analytes included in the analysis. MCV, Plt, and Fbg achieved value of <3 for level 1 (low abnormal) control. PT performed poorly on both level 1 and 2 controls with sigma value of <3. Despite acceptable conventional QC tools, application of sigma metrics can identify analytical deficits and hence prospects for the improvement in clinical laboratories. © 2016 John Wiley & Sons Ltd.
Tang, Siew Tzuh; Chang, Wen-Cheng; Chen, Jen-Shi; Chou, Wen-Chi; Hsieh, Chia-Hsun; Chen, Chen H
2016-04-01
Whether prognostic awareness benefits terminally ill cancer patients' psychological-existential well-being and quality of life (QOL) is unclear because of lack of well-controlled longitudinal studies. This study longitudinally evaluated the associations of accurate prognostic awareness and prognostic acceptance with psychological distress, existential suffering, and QOL while comprehensively controlling for confounders in Taiwanese terminally ill cancer patients' last year of life. A convenience sample of 325 cancer patients was followed until death. Psychological distress and existential suffering were assessed by severe anxiety and depressive symptoms and high self-perceived sense of burden to others, respectively. Dichotomized and continuous (QOL) outcome variables were evaluated by multivariate logistic and linear regression modeling with the generalized estimating equation, respectively. Accurate prognostic awareness was not associated with the likelihood of severe anxiety or depressive symptoms but significantly increased the likelihood of high self-perceived sense of burden to others and was associated with poorer QOL in participants' last year of life. Participants who knew and highly accepted their prognosis were significantly less likely to experience severe anxiety symptoms than those who were unaware of or knew their prognosis but had difficulty accepting it. Knowing one's poor prognosis and confronting one's impending death without full acceptance and adequate professional psycho-spiritual support may harm more than benefit terminally ill cancer patients' psychological state, existential well-being, and QOL. These findings highlight the importance of tailoring psycho-spiritual support to cancer patients' psychological and existential needs when prognostic information is disclosed. Copyright © 2015 John Wiley & Sons, Ltd.
Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith
2007-07-01
Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over-express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the "real world".
QCloud: A cloud-based quality control system for mass spectrometry-based proteomics laboratories
Chiva, Cristina; Olivella, Roger; Borràs, Eva; Espadas, Guadalupe; Pastor, Olga; Solé, Amanda
2018-01-01
The increasing number of biomedical and translational applications in mass spectrometry-based proteomics poses new analytical challenges and raises the need for automated quality control systems. Despite previous efforts to set standard file formats, data processing workflows and key evaluation parameters for quality control, automated quality control systems are not yet widespread among proteomics laboratories, which limits the acquisition of high-quality results, inter-laboratory comparisons and the assessment of variability of instrumental platforms. Here we present QCloud, a cloud-based system to support proteomics laboratories in daily quality assessment using a user-friendly interface, easy setup, automated data processing and archiving, and unbiased instrument evaluation. QCloud supports the most common targeted and untargeted proteomics workflows, it accepts data formats from different vendors and it enables the annotation of acquired data and reporting incidences. A complete version of the QCloud system has successfully been developed and it is now open to the proteomics community (http://qcloud.crg.eu). QCloud system is an open source project, publicly available under a Creative Commons License Attribution-ShareAlike 4.0. PMID:29324744
Obadina, Adewale O; Oyewole, Olusola B; Williams, Oluwasolabomi E
2013-07-01
This study was carried out to investigate and improve the traditional processing method and nutritional quality of the traditional cassava snack (Ajogun). Cassava root (Manihot esculenta Crantz L.) of TME 419 variety was processed into mash (40% moisture content). The cassava mash was mixed into different blends to produce fried traditional "Ajogun", fried and baked extrudates (modified Ajogun) as snacks. These products were analyzed to determine the proximate composition including carbohydrate, fat, protein, fiber, ash, and moisture contents and functional properties such as bulk density. The results obtained for the moisture, fat, protein, and ash contents showed significant difference (P < 0.05) between the control sample and the extrudates. However, there was no significant difference (P > 0.05) in the carbohydrate and fiber contents between the three samples. There was no significant difference (P > 0.05) in the bulk density of the snacks. Also, sensory evaluation was carried out on the cassava-based snacks using the 9-point hedonic scale to determine the degree of acceptability. Results obtained showed significant difference (P < 0.05) between the extrudates and control sample in terms of appearance, taste, flavor, color, aroma, texture, and overall acceptability. The highest acceptability level of the product was at 8.04 for the control sample (traditional Ajogun). This study has shown that "Ajogun", which is a lesser known cassava product, is rich in protein and fat.
Gattrell, William T; Hopewell, Sally; Young, Kate; Farrow, Paul; White, Richard; Wager, Elizabeth; Winchester, Christopher C
2016-02-21
Authors may choose to work with professional medical writers when writing up their research for publication. We examined the relationship between medical writing support and the quality and timeliness of reporting of the results of randomised controlled trials (RCTs). Cross-sectional study. Primary reports of RCTs published in BioMed Central journals from 2000 to 16 July 2014, subdivided into those with medical writing support (n=110) and those without medical writing support (n=123). Proportion of items that were completely reported from a predefined subset of the Consolidated Standards of Reporting Trials (CONSORT) checklist (12 items known to be commonly poorly reported), overall acceptance time (from manuscript submission to editorial acceptance) and quality of written English as assessed by peer reviewers. The effect of funding source and publication year was examined. The number of articles that completely reported at least 50% of the CONSORT items assessed was higher for those with declared medical writing support (39.1% (43/110 articles); 95% CI 29.9% to 48.9%) than for those without (21.1% (26/123 articles); 95% CI 14.3% to 29.4%). Articles with declared medical writing support were more likely than articles without such support to have acceptable written English (81.1% (43/53 articles); 95% CI 67.6% to 90.1% vs 47.9% (23/48 articles); 95% CI 33.5% to 62.7%). The median time of overall acceptance was longer for articles with declared medical writing support than for those without (167 days (IQR 114.5-231 days) vs 136 days (IQR 77-193 days)). In this sample of open-access journals, declared professional medical writing support was associated with more complete reporting of clinical trial results and higher quality of written English. Medical writing support may play an important role in raising the quality of clinical trial reporting. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Backhausen, Lea L.; Herting, Megan M.; Buse, Judith; Roessner, Veit; Smolka, Michael N.; Vetter, Nora C.
2016-01-01
In structural magnetic resonance imaging motion artifacts are common, especially when not scanning healthy young adults. It has been shown that motion affects the analysis with automated image-processing techniques (e.g., FreeSurfer). This can bias results. Several developmental and adult studies have found reduced volume and thickness of gray matter due to motion artifacts. Thus, quality control is necessary in order to ensure an acceptable level of quality and to define exclusion criteria of images (i.e., determine participants with most severe artifacts). However, information about the quality control workflow and image exclusion procedure is largely lacking in the current literature and the existing rating systems differ. Here, we propose a stringent workflow of quality control steps during and after acquisition of T1-weighted images, which enables researchers dealing with populations that are typically affected by motion artifacts to enhance data quality and maximize sample sizes. As an underlying aim we established a thorough quality control rating system for T1-weighted images and applied it to the analysis of developmental clinical data using the automated processing pipeline FreeSurfer. This hands-on workflow and quality control rating system will aid researchers in minimizing motion artifacts in the final data set, and therefore enhance the quality of structural magnetic resonance imaging studies. PMID:27999528
Bartholomay, Roy C.; Maimer, Neil V.; Wehnke, Amy J.
2014-01-01
Water-quality activities and water-level measurements by the personnel of the U.S. Geological Survey (USGS) Idaho National Laboratory (INL) Project Office coincide with the USGS mission of appraising the quantity and quality of the Nation’s water resources. The activities are carried out in cooperation with the U.S. Department of Energy (DOE) Idaho Operations Office. Results of the water-quality and hydraulic head investigations are presented in various USGS publications or in refereed scientific journals and the data are stored in the National Water Information System (NWIS) database. The results of the studies are used by researchers, regulatory and managerial agencies, and interested civic groups. In the broadest sense, quality assurance refers to doing the job right the first time. It includes the functions of planning for products, review and acceptance of the products, and an audit designed to evaluate the system that produces the products. Quality control and quality assurance differ in that quality control ensures that things are done correctly given the “state-of-the-art” technology, and quality assurance ensures that quality control is maintained within specified limits.
21 CFR 820.250 - Statistical techniques.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Statistical techniques. 820.250 Section 820.250...) MEDICAL DEVICES QUALITY SYSTEM REGULATION Statistical Techniques § 820.250 Statistical techniques. (a... statistical techniques required for establishing, controlling, and verifying the acceptability of process...
21 CFR 820.250 - Statistical techniques.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Statistical techniques. 820.250 Section 820.250...) MEDICAL DEVICES QUALITY SYSTEM REGULATION Statistical Techniques § 820.250 Statistical techniques. (a... statistical techniques required for establishing, controlling, and verifying the acceptability of process...
Design of Low Complexity Model Reference Adaptive Controllers
NASA Technical Reports Server (NTRS)
Hanson, Curt; Schaefer, Jacob; Johnson, Marcus; Nguyen, Nhan
2012-01-01
Flight research experiments have demonstrated that adaptive flight controls can be an effective technology for improving aircraft safety in the event of failures or damage. However, the nonlinear, timevarying nature of adaptive algorithms continues to challenge traditional methods for the verification and validation testing of safety-critical flight control systems. Increasingly complex adaptive control theories and designs are emerging, but only make testing challenges more difficult. A potential first step toward the acceptance of adaptive flight controllers by aircraft manufacturers, operators, and certification authorities is a very simple design that operates as an augmentation to a non-adaptive baseline controller. Three such controllers were developed as part of a National Aeronautics and Space Administration flight research experiment to determine the appropriate level of complexity required to restore acceptable handling qualities to an aircraft that has suffered failures or damage. The controllers consist of the same basic design, but incorporate incrementally-increasing levels of complexity. Derivations of the controllers and their adaptive parameter update laws are presented along with details of the controllers implementations.
Quality control developments for graphite/PMR15 polyimide composites materials
NASA Technical Reports Server (NTRS)
Sheppard, C. H.; Hoggatt, J. T.
1979-01-01
The problem of lot-to-lot and within-lot variability of graphite/PMR-15 prepreg was investigated. The PMR-15 chemical characterization data were evaluated along with the processing conditions controlling the manufacture of PMR-15 resin and monomers. Manufacturing procedures were selected to yield a consistently reproducible graphite prepreg that could be processed into acceptable structural elements.
Kim, Young Ju; Xiao, Yan; Hu, Peter; Dutton, Richard
2009-08-01
To understand staff acceptance of a remote video monitoring system for operating room (OR) coordination. Improved real-time remote visual access to OR may enhance situational awareness but also raises privacy concerns for patients and staff. Survey. A system was implemented in a six-room surgical suite to display OR monitoring video at an access restricted control desk area. Image quality was manipulated to improve staff acceptance. Two months after installation, interviews and a survey were conducted on staff acceptance of video monitoring. About half of all OR personnel responded (n = 63). Overall levels of concerns were low, with 53% rated no concerns and 42% little concern. Top two reported uses of the video were to see if cases are finished and to see if a room is ready. Viewing the video monitoring system as useful did not reduce levels of concern. Staff in supervisory positions perceived less concern about the system's impact on privacy than did those supervised (p < 0.03). Concerns for patient privacy correlated with concerns for staff privacy and performance monitoring. Technical means such as manipulating image quality helped staff acceptance. Manipulation of image quality resulted overall acceptance of monitoring video, with residual levels of concerns. OR nurses may express staff privacy concern in the form of concerns over patient privacy. This study provided suggestions for technological and implementation strategies of video monitoring for coordination use in OR. Deployment of communication technology and integration of clinical information will likely raise concerns over staff privacy and performance monitoring. The potential gain of increased information access may be offset by negative impact of a sense of loss of autonomy.
A method of setting limits for the purpose of quality assurance
NASA Astrophysics Data System (ADS)
Sanghangthum, Taweap; Suriyapee, Sivalee; Kim, Gwe-Ya; Pawlicki, Todd
2013-10-01
The result from any assurance measurement needs to be checked against some limits for acceptability. There are two types of limits; those that define clinical acceptability (action limits) and those that are meant to serve as a warning that the measurement is close to the action limits (tolerance limits). Currently, there is no standard procedure to set these limits. In this work, we propose an operational procedure to set tolerance limits and action limits. The approach to establish the limits is based on techniques of quality engineering using control charts and a process capability index. The method is different for tolerance limits and action limits with action limits being categorized into those that are specified and unspecified. The procedure is to first ensure process control using the I-MR control charts. Then, the tolerance limits are set equal to the control chart limits on the I chart. Action limits are determined using the Cpm process capability index with the requirements that the process must be in-control. The limits from the proposed procedure are compared to an existing or conventional method. Four examples are investigated: two of volumetric modulated arc therapy (VMAT) point dose quality assurance (QA) and two of routine linear accelerator output QA. The tolerance limits range from about 6% larger to 9% smaller than conventional action limits for VMAT QA cases. For the linac output QA, tolerance limits are about 60% smaller than conventional action limits. The operational procedure describe in this work is based on established quality management tools and will provide a systematic guide to set up tolerance and action limits for different equipment and processes.
Information Quality in Regulatory Decision Making: Peer Review versus Good Laboratory Practice.
McCarty, Lynn S; Borgert, Christopher J; Mihaich, Ellen M
2012-07-01
There is an ongoing discussion on the provenance of toxicity testing data regarding how best to ensure its validity and credibility. A central argument is whether journal peer-review procedures are superior to Good Laboratory Practice (GLP) standards employed for compliance with regulatory mandates. We sought to evaluate the rationale for regulatory decision making based on peer-review procedures versus GLP standards. We examined pertinent published literature regarding how scientific data quality and validity are evaluated for peer review, GLP compliance, and development of regulations. Some contend that peer review is a coherent, consistent evaluative procedure providing quality control for experimental data generation, analysis, and reporting sufficient to reliably establish relative merit, whereas GLP is seen as merely a tracking process designed to thwart investigator corruption. This view is not supported by published analyses pointing to subjectivity and variability in peer-review processes. Although GLP is not designed to establish relative merit, it is an internationally accepted quality assurance, quality control method for documenting experimental conduct and data. Neither process is completely sufficient for establishing relative scientific soundness. However, changes occurring both in peer-review processes and in regulatory guidance resulting in clearer, more transparent communication of scientific information point to an emerging convergence in ensuring information quality. The solution to determining relative merit lies in developing a well-documented, generally accepted weight-of-evidence scheme to evaluate both peer-reviewed and GLP information used in regulatory decision making where both merit and specific relevance inform the process.
Decision theory applied to image quality control in radiology.
Lessa, Patrícia S; Caous, Cristofer A; Arantes, Paula R; Amaro, Edson; de Souza, Fernando M Campello
2008-11-13
The present work aims at the application of the decision theory to radiological image quality control (QC) in diagnostic routine. The main problem addressed in the framework of decision theory is to accept or reject a film lot of a radiology service. The probability of each decision of a determined set of variables was obtained from the selected films. Based on a radiology service routine a decision probability function was determined for each considered group of combination characteristics. These characteristics were related to the film quality control. These parameters were also framed in a set of 8 possibilities, resulting in 256 possible decision rules. In order to determine a general utility application function to access the decision risk, we have used a simple unique parameter called r. The payoffs chosen were: diagnostic's result (correct/incorrect), cost (high/low), and patient satisfaction (yes/no) resulting in eight possible combinations. Depending on the value of r, more or less risk will occur related to the decision-making. The utility function was evaluated in order to determine the probability of a decision. The decision was made with patients or administrators' opinions from a radiology service center. The model is a formal quantitative approach to make a decision related to the medical imaging quality, providing an instrument to discriminate what is really necessary to accept or reject a film or a film lot. The method presented herein can help to access the risk level of an incorrect radiological diagnosis decision.
Handling qualities effects of display latency
NASA Technical Reports Server (NTRS)
King, David W.
1993-01-01
Display latency is the time delay between aircraft response and the corresponding response of the cockpit displays. Currently, there is no explicit specification for allowable display lags to ensure acceptable aircraft handling qualities in instrument flight conditions. This paper examines the handling qualities effects of display latency between 70 and 400 milliseconds for precision instrument flight tasks of the V-22 Tiltrotor aircraft. Display delay effects on the pilot control loop are analytically predicted through a second order pilot crossover model of the V-22 lateral axis, and handling qualities trends are evaluated through a series of fixed-base piloted simulation tests. The results show that the effects of display latency for flight path tracking tasks are driven by the stability characteristics of the attitude control loop. The data indicate that the loss of control damping due to latency can be simply predicted from knowledge of the aircraft's stability margins, control system lags, and required control bandwidths. Based on the relationship between attitude control damping and handling qualities ratings, latency design guidelines are presented. In addition, this paper presents a design philosophy, supported by simulation data, for using flight director display augmentation to suppress the effects of display latency for delays up to 300 milliseconds.
Beaulieu, Luc; Radford, Dee-Ann; Eduardo Villarreal-Barajas, J
2018-03-14
The Canadian Organization of Medical Physicists (COMP), in close partnership with the Canadian Partnership for Quality Radiotherapy (CPQR) has developed a series of Technical Quality Control (TQC) guidelines for radiation treatment equipment. These guidelines outline the performance objectives that equipment should meet in order to ensure an acceptable level of radiation treatment quality. The TQC guidelines have been rigorously reviewed and field tested in a variety of Canadian radiation treatment facilities. The development process enables rapid review and update to keep the guidelines current with changes in technology. This article contains detailed performance objectives and safety criteria for low-dose-rate (LDR) permanent seed brachytherapy. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Mobile phone-based clinical guidance for rural health providers in India.
Gautham, Meenakshi; Iyengar, M Sriram; Johnson, Craig W
2015-12-01
There are few tried and tested mobile technology applications to enhance and standardize the quality of health care by frontline rural health providers in low-resource settings. We developed a media-rich, mobile phone-based clinical guidance system for management of fevers, diarrhoeas and respiratory problems by rural health providers. Using a randomized control design, we field tested this application with 16 rural health providers and 128 patients at two rural/tribal sites in Tamil Nadu, Southern India. Protocol compliance for both groups, phone usability, acceptability and patient feedback for the experimental group were evaluated. Linear mixed-model analyses showed statistically significant improvements in protocol compliance in the experimental group. Usability and acceptability among patients and rural health providers were very high. Our results indicate that mobile phone-based, media-rich procedural guidance applications have significant potential for achieving consistently standardized quality of care by diverse frontline rural health providers, with patient acceptance. © The Author(s) 2014.
González, Eva; Vegara, Salud; Martí, Nuria; Valero, Manuel; Saura, Domingo
2015-03-01
Technological process for production of non-astringent persimmon (Diospyros kaki Thunb. cv. "Rojo Brillante") juice was described. The degree of fruit ripening expressed as color index (CI) varied between 12.37 and 16.33. Persimmon juice was characterized by determining physicochemical quality parameters as yield, total soluble solids (TSS), pH, titratable acidity (TA), organic acids, and main sugars. A thermal treatment of 90 ºC for 10 s was effective in controlling naturally occurring microorganisms for at least 105 d of storage without significantly affecting production of soluble brown pigments (BPs) and 5-hydroxymethyl furfural (5-HMF), total phenolic compounds (TPC), antioxidant capacity and acceptability of juice by panelists. Storage time affected all and each of the above parameters, reducing BPs, TPC and antioxidant capacity but increasing 5-HMF content. Refrigerated storage enhanced the acceptability of the juices. This information may be used by the juice industry as a starting point for production of pure persimmon juices. © 2015 Institute of Food Technologists®
Selman, Lucy; McDermott, Kelly; Donesky, DorAnne; Citron, Tracie; Howie-Esquivel, Jill
2015-02-07
Heart failure (HF) and chronic obstructive pulmonary disease (COPD) are highly prevalent and associated with a large symptom burden, that is compounded in a dual HF-COPD diagnosis. Yoga has potential benefit for symptom relief; however functional impairment hinders access to usual yoga classes. We developed a Tele-Yoga intervention and evaluated it in a controlled pilot trial. This paper reports on the appropriateness and acceptability of the intervention and the evaluation design. A controlled, non-randomised trial was conducted of an 8-week Tele-Yoga intervention versus an educational control (information leaflets mailed to participants with one phone call a week). Biweekly one-hour Tele-Yoga classes were implemented via multipoint videoconferencing that connected participants to live classes via an Internet connection to their televisions. Semi-structured qualitative interviews were conducted with participants post study exit to explore reasons for and experiences of participating, including views of study outcome measures and physiological tests. Transcribed interviews were analysed using thematic content analysis. Fifteen people participated in the pilot study (7 in the intervention group, 8 in the control). Of these, 12 participants were interviewed, 6 in each group, mean age 71.2 years (SD 10.09); 3 were male. Themes are reported in the following categories: acceptability and appropriateness of the intervention, potential active ingredients of the intervention, acceptability and appropriateness of the control, participation in the research, and acceptability of the testing procedures. The intervention was acceptable and appropriate: the intervention group reported enjoying yoga and valuing the home-based aspect and participants described a high symptom burden and social isolation. However, technological problems resulted in poor video-streaming quality for some participants. Potential active ingredients included physical postures, breathing exercises and guidance in relaxation and meditation. The educational control intervention was acceptable and appropriate, with participants reporting little effect on their well-being and no impact on mechanisms hypothesised to explain yoga's effectiveness. The questionnaires and home physiological testing were acceptable to participants. Tele-Yoga is an acceptable and appropriate intervention in people with HF and COPD and further research is warranted to refine the technology used in its delivery. Findings provide guidance for researchers working in tele-interventions, yoga, and similar populations. ClinicalTrials.gov Identifier: NCT02078739 (4 March 2014).
Chen, Xinyuan; Dai, Jianrong
2018-05-01
Magnetic Resonance Imaging (MRI) simulation differs from diagnostic MRI in purpose, technical requirements, and implementation. We propose a semiautomatic method for image acceptance and commissioning for the scanner, the radiofrequency (RF) coils, and pulse sequences for an MRI simulator. The ACR MRI accreditation large phantom was used for image quality analysis with seven parameters. Standard ACR sequences with a split head coil were adopted to examine the scanner's basic performance. The performance of simulation RF coils were measured and compared using the standard sequence with different clinical diagnostic coils. We used simulation sequences with simulation coils to test the quality of image and advanced performance of the scanner. Codes and procedures were developed for semiautomatic image quality analysis. When using standard ACR sequences with a split head coil, image quality passed all ACR recommended criteria. The image intensity uniformity with a simulation RF coil decreased about 34% compared with the eight-channel diagnostic head coil, while the other six image quality parameters were acceptable. Those two image quality parameters could be improved to more than 85% by built-in intensity calibration methods. In the simulation sequences test, the contrast resolution was sensitive to the FOV and matrix settings. The geometric distortion of simulation sequences such as T1-weighted and T2-weighted images was well-controlled in the isocenter and 10 cm off-center within a range of ±1% (2 mm). We developed a semiautomatic image quality analysis method for quantitative evaluation of images and commissioning of an MRI simulator. The baseline performances of simulation RF coils and pulse sequences have been established for routine QA. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Design and pilot evaluation of the RAH-66 Comanche Core AFCS
NASA Technical Reports Server (NTRS)
Fogler, Donald L., Jr.; Keller, James F.
1993-01-01
This paper addresses the design and pilot evaluation of the Core Automatic Flight Control System (AFCS) for the Reconnaissance/Attack Helicopter (RAH-66) Comanche. During the period from November 1991 through February 1992, the RAH-66 Comanche control laws were evaluated through a structured pilot acceptance test using a motion base simulator. Design requirements, descriptions of the control law design, and handling qualities data collected from ADS-33 maneuvers are presented.
Polański, Jacek; Jankowska-Polanska, Beata; Lomper, Katarzyna; Janczak, Dariusz; Rosinczuk, Joanna
2017-01-01
Background Lung cancer is the major cause of cancer related deaths worldwide. The overall 5-year survival rate is very low and accounts for only 15%. Poor quality of life is considered a prognostic factor for shorter survival in lung cancer patients. The aim of the study was to examine the relationships between pain, the acceptance of illness and quality of life in patients with lung cancer. Methods The study included 155 patients with lung cancer with mean age of 62.23 [standard deviation (SD)=9.86] years. We used the Acceptance of Illness Scale (AIS) and the Visual Analog Scale (VAS) for pain, and the Short Form Health Survey (SF-8) for the assessment of quality of life. For statistical analysis, Spearman’s rank correlation coefficient and linear regression method were used. Results Mean score of the acceptance of illness was 27.1 (SD=9.2). Mean score of the pain severity as measured by the VAS was 4.07 (SD=1.83). The acceptance of illness was significantly positively correlated with all the domains of quality of life. Both the AIS and the VAS were independent determinants of physical and mental components of quality of life. Age and World Health Organization (WHO) performance status were additional predictors of physical component of quality of life. Conclusions The knowledge about the acceptance of illness, consequences of the decreased acceptance of illness, and factors affecting its level in patients with lung cancer is still insufficient. Relationships among acceptance of illness, quality of life, and pain should be further investigated. PMID:29221267
Chabowski, Mariusz; Polański, Jacek; Jankowska-Polanska, Beata; Lomper, Katarzyna; Janczak, Dariusz; Rosinczuk, Joanna
2017-09-01
Lung cancer is the major cause of cancer related deaths worldwide. The overall 5-year survival rate is very low and accounts for only 15%. Poor quality of life is considered a prognostic factor for shorter survival in lung cancer patients. The aim of the study was to examine the relationships between pain, the acceptance of illness and quality of life in patients with lung cancer. The study included 155 patients with lung cancer with mean age of 62.23 [standard deviation (SD)=9.86] years. We used the Acceptance of Illness Scale (AIS) and the Visual Analog Scale (VAS) for pain, and the Short Form Health Survey (SF-8) for the assessment of quality of life. For statistical analysis, Spearman's rank correlation coefficient and linear regression method were used. Mean score of the acceptance of illness was 27.1 (SD=9.2). Mean score of the pain severity as measured by the VAS was 4.07 (SD=1.83). The acceptance of illness was significantly positively correlated with all the domains of quality of life. Both the AIS and the VAS were independent determinants of physical and mental components of quality of life. Age and World Health Organization (WHO) performance status were additional predictors of physical component of quality of life. The knowledge about the acceptance of illness, consequences of the decreased acceptance of illness, and factors affecting its level in patients with lung cancer is still insufficient. Relationships among acceptance of illness, quality of life, and pain should be further investigated.
A simple control for sediment-toxicity exposures using the amphipod, Hyalella azteca
Lasier, Peter J.; Urich, Matthew L.
2014-01-01
Sediment-toxicity exposures comparing survival and growth of the freshwater amphipod, Hyalella azteca, are often components of aquatic-habitat assessments. Standardized exposure methods have been established and require evaluations for quality assurance. Test acceptability using performance-based criteria can be determined from exposures to control sediments, which are collected from the environment or formulated from commercially available components. Amending sand with leached alfalfa solids provided a simple formulated sediment that elicited consistently acceptable survival and growth in 28-day exposures with and without a daily feeding regime. A procedure is described for preparing the sediment along with results from comparisons among sand, amended sand, and field-collected sediments that incorporated three feeding regimes.
2013-01-01
Background The use of substandard and degraded medicines is a major public health problem in developing countries such as Cambodia. A collaborative study was conducted to evaluate the quality of amoxicillin–clavulanic acid preparations under tropical conditions in a developing country. Methods Amoxicillin-clavulanic acid tablets were obtained from outlets in Cambodia. Packaging condition, printed information, and other sources of information were examined. The samples were tested for quantity, content uniformity, and dissolution. Authenticity was verified with manufacturers and regulatory authorities. Results A total of 59 samples were collected from 48 medicine outlets. Most (93.2%) of the samples were of foreign origin. Using predetermined acceptance criteria, 12 samples (20.3%) were non-compliant. Eight (13.6%), 10 (16.9%), and 20 (33.9%) samples failed quantity, content uniformity, and dissolution tests, respectively. Samples that violated our observational acceptance criteria were significantly more likely to fail the quality tests (Fisher’s exact test, p < 0.05). Conclusions Improper packaging and storage conditions may reduce the quality of amoxicillin–clavulanic acid preparations at community pharmacies. Strict quality control measures are urgently needed to maintain the quality of amoxicillin–clavulanic acid in tropical countries. PMID:23773420
Kap, Marcel; Oomen, Monique; Arshad, Shazia; de Jong, Bas; Riegman, Peter
2014-04-01
About 5000 frozen tissue samples are collected each year by the Erasmus Medical Center tissue bank. Two percent of these samples are randomly selected annually for RNA isolation and RNA Integrity Number (RIN) measurement. A similar quality assessment was conducted during centralization of a 20-year-old tissue collection from the cancer institute, a 15-year-old liver sample archive (-80°C), and a 13-year-old clinical pathology frozen biopsy archive (Liquid Nitrogen). Samples were divided into either high-quality (RIN ≥6.5) or low-quality overall categories, or into four "fit-for-purpose" quality groups: RIN <5: not reliable for demanding downstream analysis; 5 ≤RIN <6: suitable for RT-qPCR; 6 ≤RIN <8: suitable for gene array analysis; and RIN ≥8: suitable for all downstream techniques. In general, low RIN values were correlated with fatty, fibrous, pancreatic, or necrotic tissue. When the percentage of samples with RIN ≥6.5 is higher than 90%, the tissue bank performance is adequate. The annual 2011 quality control assessment showed that 90.3% (n=93) of all samples had acceptable RIN values; 97.4% (n=39) of the cancer institute collection had RIN values above 6.5; and 88.6% (n=123) of samples from the liver sample archive collection had RIN values higher than 6.5. As the clinical pathology biopsy collection contained only 58.8% (n=24) acceptable samples, the procurement protocols used for these samples needed immediate evaluation. When the distribution of RIN values of the different collections were compared, no significant differences were found, despite differences in average storage time and temperature. According to the principle of "fit-for-purpose" distribution, the vast majority of samples are considered good enough for most downstream techniques. In conclusion, an annual tissue bank quality control procedure provides useful information on tissue sample quality and sheds light on where and if improvements need to be made.
Intelligent Processing Equipment Projects at DLA
NASA Technical Reports Server (NTRS)
Obrien, Donald F.
1992-01-01
The Defense Logistics Agency is successfully incorporating Intelligent Processing Equipment (IPE) into each of its Manufacturing Technology thrust areas. Several IPE applications are addressed in the manufacturing of two 'soldier support' items: combat rations and military apparel. In combat rations, in-line sensors for food processing are being developed or modified from other industries. In addition, many process controls are being automated to achieve better quality and to gain higher use (soldier) acceptance. IPE applications in military apparel include: in-process quality controls for identification of sewing defects, use of robots in the manufacture of shirt collars, and automated handling of garments for pressing.
Intelligent processing equipment projects at DLA
NASA Astrophysics Data System (ADS)
Obrien, Donald F.
1992-04-01
The Defense Logistics Agency is successfully incorporating Intelligent Processing Equipment (IPE) into each of its Manufacturing Technology thrust areas. Several IPE applications are addressed in the manufacturing of two 'soldier support' items: combat rations and military apparel. In combat rations, in-line sensors for food processing are being developed or modified from other industries. In addition, many process controls are being automated to achieve better quality and to gain higher use (soldier) acceptance. IPE applications in military apparel include: in-process quality controls for identification of sewing defects, use of robots in the manufacture of shirt collars, and automated handling of garments for pressing.
Quality Assurance and Control Considerations in Environmental Measurements and Monitoring
NASA Astrophysics Data System (ADS)
Sedlet, Jacob
1982-06-01
Quality assurance and quality control have become accepted as essential parts of all environmental surveillance, measurements, and monitoring programs, both nuclear and non-nuclear. The same principles and details apply to each. It is primarily the final measurement technique that differs. As the desire and need to measure smaller amounts of pollutants with greater accuracy has increased, it has been recognized that quality assurance and control programs are cost-effective in achieving the expected results. Quality assurance (QA) consists of all the actions necessary to provide confidence in the results. Quality control (QC) is a part of QA, and consists of those actions and activities that permit the control of the individual steps in the environmental program. The distinction between the two terms is not always clearly defined, but a sharp division is not necessary. The essential principle of QA and QC is a commitment to high quality results. The essential components of a QA and QC program are a complete, written procedures manual for all parts of the environmental program, the use of standard or validated procedures, participation in applicable interlaboratory comparison or QA programs, replicate analysis and measurement, training of personnel, and a means of auditing or checking that the QA and QC programs are properly conducted. These components are discussed below in some detail.
Code of Federal Regulations, 2011 CFR
2011-07-01
... level and passing and failing criteria for selective enforcement audits. 91.608 Section 91.608... with acceptable quality level and passing and failing criteria for selective enforcement audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed engine is one whose final test...
Code of Federal Regulations, 2013 CFR
2013-07-01
... level and passing and failing criteria for selective enforcement audits. 89.510 Section 89.510... Compliance with acceptable quality level and passing and failing criteria for selective enforcement audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed engine is one whose final...
Code of Federal Regulations, 2014 CFR
2014-07-01
... level and passing and failing criteria for selective enforcement audits. 89.510 Section 89.510... Compliance with acceptable quality level and passing and failing criteria for selective enforcement audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed engine is one whose final...
Code of Federal Regulations, 2014 CFR
2014-07-01
... level and passing and failing criteria for selective enforcement audits. 91.608 Section 91.608... with acceptable quality level and passing and failing criteria for selective enforcement audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed engine is one whose final test...
Code of Federal Regulations, 2013 CFR
2013-07-01
... level and passing and failing criteria for selective enforcement audits. 91.608 Section 91.608... with acceptable quality level and passing and failing criteria for selective enforcement audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed engine is one whose final test...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Compliance with acceptable quality level and passing and failing criteria for selective enforcement audits. 90.510 Section 90.510....510 Compliance with acceptable quality level and passing and failing criteria for selective...
Impact on quality activities of measurement systems meeting an L:1 rule
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamada, M. S.; Burkhardt, J. H.
2016-04-01
This study considers the impact of a measurement system that meets an L:1 rule on various quality activities. These activities include inspection, acceptance sampling, and control charting. A measurement system that meets a 10:1 rule performs much better than one that meets a 4:1 rule. R code is provided so that the practitioner is able to evaluate these activities to his or her particular situation.
Active controls for ride smoothing
NASA Technical Reports Server (NTRS)
Conner, D. W.; Thompson, G. O.
1976-01-01
Active controls technology offers great promise for significantly smoothing the ride, and thus improving public and air carrier acceptance, of certain types of transport aircraft. Recent findings which support this promise are presented in the following three pertinent areas: (1) Ride quality versus degree of traveler satisfaction; (2) significant findings from a feasibility study of a ride smoothing system; and (3) potential ride problems identified for several advanced transport concepts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jantzen, C.; Johnson, F.
2012-06-05
During melting of HLW glass, the REDOX of the melt pool cannot be measured. Therefore, the Fe{sup +2}/{Sigma}Fe ratio in the glass poured from the melter must be related to melter feed organic and oxidant concentrations to ensure production of a high quality glass without impacting production rate (e.g., foaming) or melter life (e.g., metal formation and accumulation). A production facility such as the Defense Waste Processing Facility (DWPF) cannot wait until the melt or waste glass has been made to assess its acceptability, since by then no further changes to the glass composition and acceptability are possible. therefore, themore » acceptability decision is made on the upstream process, rather than on the downstream melt or glass product. That is, it is based on 'feed foward' statistical process control (SPC) rather than statistical quality control (SQC). In SPC, the feed composition to the melter is controlled prior to vitrification. Use of the DWPF REDOX model has controlled the balanjce of feed reductants and oxidants in the Sludge Receipt and Adjustment Tank (SRAT). Once the alkali/alkaline earth salts (both reduced and oxidized) are formed during reflux in the SRAT, the REDOX can only change if (1) additional reductants or oxidants are added to the SRAT, the Slurry Mix Evaporator (SME), or the Melter Feed Tank (MFT) or (2) if the melt pool is bubble dwith an oxidizing gas or sparging gas that imposes a different REDOX target than the chemical balance set during reflux in the SRAT.« less
Payne, Velma L; Hysong, Sylvia J
2016-07-13
Audit and feedback (A&F) is a strategy that has been used in various disciplines for performance and quality improvement. There is limited research regarding medical professionals' acceptance of clinical-performance feedback and whether feedback impacts clinical practice. The objectives of our research were to (1) investigate aspects of A&F that impact physicians' acceptance of performance feedback; (2) determine actions physicians take when receiving feedback; and (3) determine if feedback impacts physicians' patient-management behavior. In this qualitative study, we employed grounded theory methods to perform a secondary analysis of semi-structured interviews with 12 VA primary care physicians. We analyzed a subset of interview questions from the primary study, which aimed to determine how providers of high, low and moderately performing VA medical centers use performance feedback to maintain and improve quality of care, and determine perceived utility of performance feedback. Based on the themes emergent from our analysis and their observed relationships, we developed a model depicting aspects of the A&F process that impact feedback acceptance and physicians' patient-management behavior. The model is comprised of three core components - Reaction, Action and Impact - and depicts elements associated with feedback recipients' reaction to feedback, action taken when feedback is received, and physicians modifying their patient-management behavior. Feedback characteristics, the environment, external locus-of-control components, core values, emotion and the assessment process induce or deter reaction, action and impact. Feedback characteristics (content and timeliness), and the procedural justice of the assessment process (unjust penalties) impact feedback acceptance. External locus-of-control elements (financial incentives, competition), the environment (patient volume, time constraints) and emotion impact patient-management behavior. Receiving feedback generated intense emotion within physicians. The underlying source of the emotion was the assessment process, not the feedback. The emotional response impacted acceptance, impelled action or inaction, and impacted patient-management behavior. Emotion intensity was associated with type of action taken (defensive, proactive, retroactive). Feedback acceptance and impact have as much to do with the performance assessment process as it does the feedback. In order to enhance feedback acceptance and the impact of feedback, developers of clinical performance systems and feedback interventions should consider multiple design elements.
33 CFR 159.317 - Sampling and reporting.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) POLLUTION MARINE SANITATION DEVICES Discharge of Effluents in Certain Alaskan Waters by Cruise Vessel... cruise vessel that discharges treated sewage and/or graywater in the applicable waters of Alaska shall.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...
33 CFR 159.317 - Sampling and reporting.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) POLLUTION MARINE SANITATION DEVICES Discharge of Effluents in Certain Alaskan Waters by Cruise Vessel... cruise vessel that discharges treated sewage and/or graywater in the applicable waters of Alaska shall.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...
33 CFR 159.317 - Sampling and reporting.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) POLLUTION MARINE SANITATION DEVICES Discharge of Effluents in Certain Alaskan Waters by Cruise Vessel... cruise vessel that discharges treated sewage and/or graywater in the applicable waters of Alaska shall.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...
Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith
2007-01-01
Background and Aims Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over‐express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. Methods FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Results Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. Conclusions The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the “real world”. PMID:16963466
Cho, Yeoungjee; Pascoe, Elaine M.; Hawley, Carmel M.; Oliver, Veronica; Frazier, Jeremy; Jarvis, Elizabeth; Tan, Ken-Soon; Liu, Xusheng; Gobe, Glenda
2017-01-01
Objectives. To compare the effectiveness of real acupressure versus sham acupressure therapy in improving sleep quality in patients receiving hemodialysis (HD) or hemodiafiltration (HDF). Methods. A multicenter, single-blind, randomized controlled trial was conducted in two Australian dialysis units located in Princess Alexandra Hospital and Logan Hospital, respectively. Forty-two subjects with self-reported poor sleep quality were randomly assigned to real (n = 21) or sham (n = 21) acupressure therapy delivered thrice weekly for four consecutive weeks during routine dialysis sessions. The primary outcome was the Pittsburgh Sleep Quality Index (PSQI) score measured at week four adjusted for baseline PSQI measurements. Secondary outcomes were quality of life (QOL) (SF-8), adverse events, and patient acceptability (treatment acceptability questionnaire, TAQ). Results. The two groups were comparable on global PSQI scores (difference 0.19, 95% confidence interval [CI] −1.32 to 1.70) and on the subscale scores. Similar results were observed for QOL both in the mental (difference −3.88, 95% CI −8.63 to 0.87) and the physical scores (difference 2.45, 95% CI −1.69 to 6.58). There were no treatment-related adverse events and acupressure was perceived favorably by participants. Conclusion. Acupressure is a safe, well-tolerated, and highly acceptable therapy in adult hemodialysis patients in a Western healthcare setting with uncertain implications for therapeutic efficacy. PMID:28316636
Use of behavioral avoidance testing in natural resource damage assessment
Lipton, J.; Little, E.E.; Marr, J.C.A.; DeLonay, A.J.; Bengston, David A.; Henshel, Diane S.
1996-01-01
Natural Resource Damage Assessment (NRDA) provisions established under federal and state statutes enable natural resource trustees to recover compensation from responsible parties to restore injured natural resources. Behavioral avoidance testing with fish has been used in NRDAs to determine injuries to natural resources and to establish restoration thresholds. In this manuscript we evaluate the use of avoidance testing to NRDA. Specifically, we discuss potential “acceptance criteria” to evaluate the applicability and relevance of avoidance testing. These acceptance criteria include: (1) regulatory relevance, (2) reproducibility of testing, (3) ecological significance, (4) quality assurance/quality control, and (5) relevance to restoration. We discuss each of these criteria with respect to avoidance testing. Overall, we conclude that avoidance testing can be an appropriate, defensible, and desirable aspect of an NRDA.
2016-01-01
Background In moving toward malaria elimination, one strategy is to implement an active surveillance system for effective case management. Thailand has developed and implemented the electronic Malaria Information System (eMIS) capturing individualized electronic records of suspected or confirmed malaria cases. Objective The main purpose of this study was to determine how well the eMIS improves the quality of Thailand’s malaria surveillance system. In particular, the focus of the study was to evaluate the effectiveness of the eMIS in terms of the system users’ perception and the system outcomes (ie, quality of data) regarding the management of malaria patients. Methods A mixed-methods technique was used with the framework based on system effectiveness attributes: data quality, timeliness, simplicity, acceptability, flexibility, stability, and usefulness. Three methods were utilized: data records review, survey of system users, and in-depth interviews with key stakeholders. From the two highest endemic provinces, paper forms matching electronic records of 4455 noninfected and 784 malaria-infected cases were reviewed. Web-based anonymous questionnaires were distributed to all 129 eMIS data entry staff throughout Thailand, and semistructured interviews were conducted with 12 management-level officers. Results The eMIS is well accepted by system users at both management and operational levels. The data quality has enabled malaria personnel to perform more effective prevention and control activities. There is evidence of practices resulting in inconsistencies and logical errors in data reporting. Critical data elements were mostly completed, except for a few related to certain dates and area classifications. Timeliness in reporting a case to the system was acceptable with a delay of 3-4 days. The evaluation of quantitative and qualitative data confirmed that the eMIS has high levels of simplicity, acceptability, stability, and flexibility. Conclusions Overall, the system implemented has achieved its objective. The results of the study suggested that the eMIS helps improve the quality of Thailand’s malaria surveillance system. As the national malaria surveillance system, the eMIS’s functionalities have provided the malaria staff working at the point of care with close-to-real-time case management data quality, covering case detection, case investigation, drug compliance, and follow-up visits. Such features has led to an improvement in the quality of the malaria control program; the government officials now have quicker access to both individual and aggregated data to promptly react to possible outbreak. The eMIS thus plays one of the key roles in moving toward the national goal of malaria elimination by the next decade. PMID:27227156
De Clercq, K; Goris, N; Barnett, P V; MacKay, D K
2008-01-01
The last decade international trade in animals and animal products was liberated and confidence in this global trade can increase only if appropriate control measures are applied. As foot-and-mouth disease (FMD) diagnostics will play an essential role in this respect, the Food and Agriculture Organization European Commission for the Control of Foot-and-Mouth Disease (EUFMD) co-ordinates, in collaboration with the European Commission, several programmes to increase the quality of FMD diagnostics. A quality assurance (QA) system is deemed essential for laboratories involved in certifying absence of FMDV or antibodies against the virus. Therefore, laboratories are encouraged to validate their diagnostic tests fully and to install a continuous quality control (QC) monitoring system. Knowledge of performance characteristics of diagnostics is essential to interpret results correctly and to calculate sample rates in regional surveillance campaigns. Different aspects of QA/QC of classical and new FMD virological and serological diagnostics are discussed in respect to the EU FMD directive (2003/85/EC). We recommended accepting trade certificates only from laboratories participating in international proficiency testing on a regular basis.
Chambers, SK; Morris, BA; Clutton, S; Foley, E; Giles, L; Schofield, P; O'Connell, D; Dunn, J
2015-01-01
People with lung cancer experience health-related stigma that is related to poorer psychosocial and quality of life outcomes. The present Phase 1 study applied mixed methods to test the acceptability of an acceptance-focused cognitive behavioural intervention targeting stigma for this patient group. Fourteen lung cancer patients completed a 6-week Psychological Wellness intervention with pre- and post-test outcome measures of psychological and cancer-specific distress, depression, health-related stigma and quality of life. In-depth interviews applying interpretative phenomenological analysis assessed participants' experiences of the intervention. Moderate to large improvements were observed in psychological (ηp2 = 0.182) and cancer-specific distress (ηp2 = 0.056); depression (ηp2 = 0.621); health-related stigma (ηp2 = 0.139). In contrast, quality of life declined (ηp2 = 0.023). The therapeutic relationship; self-management of distress; and relationship support were highly valued aspects of the intervention. Barriers to intervention included avoidance and practical issues. The lung cancer patients who completed the Psychological Wellness intervention reported improvements in psychological outcomes and decreases in stigma in the face of declining quality of life with patients reporting personal benefit from their own perspectives. A randomised controlled trial is warranted to establish the effectiveness of this approach. PMID:25053458
Obadina, Adewale O; Oyewole, Olusola B; Williams, Oluwasolabomi E
2013-01-01
This study was carried out to investigate and improve the traditional processing method and nutritional quality of the traditional cassava snack (Ajogun). Cassava root (Manihot esculenta Crantz L.) of TME 419 variety was processed into mash (40% moisture content). The cassava mash was mixed into different blends to produce fried traditional “Ajogun”, fried and baked extrudates (modified Ajogun) as snacks. These products were analyzed to determine the proximate composition including carbohydrate, fat, protein, fiber, ash, and moisture contents and functional properties such as bulk density. The results obtained for the moisture, fat, protein, and ash contents showed significant difference (P < 0.05) between the control sample and the extrudates. However, there was no significant difference (P > 0.05) in the carbohydrate and fiber contents between the three samples. There was no significant difference (P > 0.05) in the bulk density of the snacks. Also, sensory evaluation was carried out on the cassava-based snacks using the 9-point hedonic scale to determine the degree of acceptability. Results obtained showed significant difference (P < 0.05) between the extrudates and control sample in terms of appearance, taste, flavor, color, aroma, texture, and overall acceptability. The highest acceptability level of the product was at 8.04 for the control sample (traditional Ajogun). This study has shown that “Ajogun”, which is a lesser known cassava product, is rich in protein and fat. PMID:24804039
Parental social coaching promotes adolescent peer acceptance across the middle school transition.
Gregson, Kim D; Tu, Kelly M; Erath, Stephen A; Pettit, Gregory S
2017-09-01
The present study investigated longitudinal associations between behavioral and cognitive dimensions of parental social coaching (i.e., advice about how to behave or think about peer challenges) and young adolescents' peer acceptance, and whether such associations are moderated by youths' social skills. Time 1 (T1) participants included 123 young adolescents (M age = 12.03 years; 50% boys; 58.5% European American). Parents gave open-ended reports about their social coaching to hypothetical peer stress scenarios, which were coded from low to high quality on behavioral and cognitive dimensions. Parents and teachers reported on adolescent prosocial behavior (i.e., social-behavioral skills), and adolescents reported on their social appraisals and social self-efficacy (i.e., social-cognitive skills). At T1 (before the first year of middle school) and Time 2 (approximately 10 months later, after the first year of middle school), parents and teachers rated adolescent peer acceptance. Analyses revealed that parents' prosocial behavioral advice and benign cognitive framing independently predicted adolescents' higher peer acceptance prospectively (controlling for earlier levels of peer acceptance). Furthermore, adolescent social skills moderated links between coaching and peer acceptance. Specifically, adolescents with higher, but not lower, social-cognitive skills became more accepted in the context of higher-quality coaching, supporting a "capitalization" pattern, such that these youth may be better able to utilize coaching suggestions. Results underscore the utility of parents' behavioral advice and cognitive framing for adolescent peer adjustment across the middle school transition and suggest that optimal social-coaching strategies may depend in part on adolescent social skill level. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Popova, A Yu; Trukhina, G M; Mikailova, O M
In the article there is considered the quality control and safety system implemented in the one of the largest flight catering food production plant for airline passengers and flying squad. The system for the control was based on the Hazard Analysis And Critical Control Points (HACCP) principles and developed hygienic and antiepidemic measures. There is considered the identification of hazard factors at stages of the technical process. There are presented results of the analysis data of monitoring for 6 critical control points over the five-year period. The quality control and safety system permit to decline food contamination risk during acceptance, preparation and supplying of in-flight meal. There was proved the efficiency of the implemented system. There are determined further ways of harmonization and implementation for HACCP principles in the plant.
It has become generally accepted that water quality can deteriorate in a distribution system through reactions in the bulk phase and/or at the pipe wall. These reactions may be physical, chemical and/or microbiological in nature. Perhaps one of the most serious aspects of water...
EPA‘s Environmental Technology Verification program is designed to further environmental protection by accelerating the acceptance and use of improved and cost effective technologies. This is done by providing high-quality, peer reviewed data on technology performance to those in...
Hui, Guohua; Liu, Wei; Feng, Hailin; Li, Jian; Gao, Yuanyuan
2016-07-15
Effects of chitosan combined with different concentrations of nisin on quality enhancement of large yellow croaker (Pseudosciaena crocea) stored at 4 °C were evaluated for 8 days. Changes in sensory score and volatile spoilage products, total viable counts (TVC), and physiochemical indexes including weight loss, colour, pH, total volatile basic nitrogen (TVB-N), and K-value were examined. Results demonstrated that nisin-treated samples presented better quality preservation effects than chitosan alone. 1% chitosan combined with 0.6% nisin presented optimal quality enhancement effects, such as moisture loss control, volatile spoilage inhibition, TVB-N reduction, TVC growth control, and colour and sensory acceptability maintenance. Therefore, chitosan combined with nisin is promising in large yellow croaker shelf life extension. Copyright © 2016 Elsevier Ltd. All rights reserved.
Relationship Between Consumer Acceptability and Pungency-Related Flavor Compounds of Vidalia Onions.
Kim, Ha-Yeon; Jackson, Daniel; Adhikari, Koushik; Riner, Cliff; Sanchez-Brambila, Gabriela
2017-10-01
A consumer study was conducted to evaluate preferences in Vidalia onions, and define consumer acceptability thresholds for commonly analyzed flavor compounds associated with pungency. Two varieties of Vidalia onions (Plethora and Sapelo Sweet) were grown at 3 fertilizer application rates (37.5 and 0; 134.5 and 59.4; and 190 and 118.8 kg/ha of nitrogen and sulfur, respectively), creating 6 treatments with various flavor attributes to use in the study. Bulb soluble solids, sugars, pyruvic acid, lachrymatory factor (LF; propanethial S-oxide), and methyl thiosulfinate (MT) content were determined and compared to sensory responses for overall liking, intensity of the sharp/pungent/burning sensation (SPB), and intent to buy provided by 142 consumers. Onion pyruvate, LF, MT, and sugar content increased as fertilization rate increased, regardless of onion variety. Consumer responses showed participants preferred onions with low SPB, which correlated positively to lower pyruvate, LF and MT concentrations, but showed no relationship to total sugars in the onion bulb. Regression analyses revealed that the majority of consumers (≥55%) found the flavor of Vidalia onions acceptable when the concentrations of LF, pyruvic acid, and MT within the bulbs were below 2.21, 4.83, and 0.43 nmol/mL, respectively. These values will support future studies aimed at identifying the optimal cultivation practices for production of sweet Vidalia onions, and can serve as an industry benchmark for quality control, thus ensuring the flavor of Vidalia onions will be acceptable to the majority of consumers. This study identified the relationship between consumer preferences and commonly analyzed flavor compounds in Vidalia onions, and established thresholds for these compounds at concentrations which the majority of consumers will find desirable. These relationships and thresholds will support future research investigating how cultural practices impact onion quality, and can be used to assist growers in variety selection decisions. In addition, this information will provide a benchmark to Vidalia onion producers for quality control of the sweet onions produced, ensuring that the onions are consistently of a desired quality, thereby increasing consumer's reliability in the Vidalia onion brand. © 2017 Institute of Food Technologists®.
Dynamics, stability, and control of maglev systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, Y.; Chen, S.S.; Rote, D.M.
1993-06-01
The dynamic response of maglev systems is important in several respects: Safety and ride quality, guideway design, and system costs. The dynamic response of vehicles is the key element in the determination of ride quality, and vehicle stability is one of the important elements relative to safety. To design a proper guideway that provides acceptable ride quality in the stable region, the vehicle dynamics must be understood. The trade-off between guideway smoothness and the levitation and control systems must be considered if maglev systems are to be economically feasible. This paper is a summary of our previous work on dynamics,more » stability and control of maglev systems. First of all, the importance of dynamics of vehicle/guideway of maglev systems is discussed. Emphasis is placed on the modeling vehicle/guideway interactions of maglev systems with a multicar, or multiload vehicle traversing on a single or double-span flexible guideway. Coupled effects of vehicle/guideway interactions in wide range of vehicle speeds with various vehicle and guideway parameters for maglev systems are investigated. Secondly, the alternative control designs of maglev vehicle suspension systems are investigated in this study to achieve safe, stable operation and acceptable ride comfort requires some form of vehicle motion control. Active and semi-active control law designs are introduced into primary and secondary suspensions of maglev vehicles. Finally, this paper discusses the stability of maglev systems based on experimental data, scoping calculations, and simple mathematical models. Divergence and flutter are obtained for coupled vibration of a three-degree-of-freedom maglev vehicle on a guideway consisting of double L-shaped aluminum segments. The theory and analysis developed in this study provides basic stability characteristics and identifies future research needs for maglev systems.« less
Dynamics, stability, and control of maglev systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, Y.; Chen, S.S.; Rote, D.M.
1993-01-01
The dynamic response of maglev systems is important in several respects: Safety and ride quality, guideway design, and system costs. The dynamic response of vehicles is the key element in the determination of ride quality, and vehicle stability is one of the important elements relative to safety. To design a proper guideway that provides acceptable ride quality in the stable region, the vehicle dynamics must be understood. The trade-off between guideway smoothness and the levitation and control systems must be considered if maglev systems are to be economically feasible. This paper is a summary of our previous work on dynamics,more » stability and control of maglev systems. First of all, the importance of dynamics of vehicle/guideway of maglev systems is discussed. Emphasis is placed on the modeling vehicle/guideway interactions of maglev systems with a multicar, or multiload vehicle traversing on a single or double-span flexible guideway. Coupled effects of vehicle/guideway interactions in wide range of vehicle speeds with various vehicle and guideway parameters for maglev systems are investigated. Secondly, the alternative control designs of maglev vehicle suspension systems are investigated in this study to achieve safe, stable operation and acceptable ride comfort requires some form of vehicle motion control. Active and semi-active control law designs are introduced into primary and secondary suspensions of maglev vehicles. Finally, this paper discusses the stability of maglev systems based on experimental data, scoping calculations, and simple mathematical models. Divergence and flutter are obtained for coupled vibration of a three-degree-of-freedom maglev vehicle on a guideway consisting of double L-shaped aluminum segments. The theory and analysis developed in this study provides basic stability characteristics and identifies future research needs for maglev systems.« less
Environment-friendly cycle time optimization and quality improvisation using Six Sigma.
Deshpande, V S; Mungle, N P
2008-07-01
Healthy environment in any organization can make a difference in improving productivity and quality with low defect, lack of concentration, willingness to work, minimum accidental problems etc. Six Sigma is one of the more recent quality improvement initiatives to gain popularity and acceptance in many industries across the globe. It is an alternative to TQM to obtain minimum manufacturing defect, cycle time reduction, cost reduction, inventory reduction etc. Its use is increasingly widespread in many industries, in both manufacturing and service industries with many proponents of the approach claiming that it has developed beyond a quality control approach into a broader process improvement concept.
NASA Technical Reports Server (NTRS)
James, John T.
2007-01-01
The toxicological assessments of 2 grab sample canisters (GSCs) and one pair of formaldehyde badges from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 120, 117, and 122 %, respectively. Three formaldehyde controls averaged 98% recovery. The Shuttle atmosphere was acceptable for human respiration. The toxicological assessment of 8 GSCs and 6 pairs of formaldehyde badges from the ISS is shown. The recoveries of the 3 standards (as listed above) from the GSCs averaged 99, 99 and 99%, respectively. Three formaldehyde control badges averaged 98% recovery. Based on these limited samples, the ISS atmosphere is acceptable for human respiration. The alcohol levels were well controlled throughout the period of sampling.
Critical review on non-operative management of adolescent idiopathic scoliosis.
Wong, M S; Liu, W C
2003-12-01
There are a number of different non-operative interventions which aim to control moderate adolescent idiopathic scoliosis (AIS) from progression. Clinicians may find difficulties in the selection of appropriate interventions for AIS. A comprehensive literature review was carried out to study all contemporary non-operative interventions, it was noted that rigid spinal orthoses apparently give more curve control; however, it would compromise the patient's quality of life via those inevitable factors--physical constraint, poor acceptance and psychological disturbance. There is a trend to develop more effective, acceptable and user-friendly interventions. Under such an aspiration, the theories and clinical evidence of different interventions should be developed along the clinical pathway of early intervention with reliable indicators/predictors, patient's active participation, dynamic control mechanism, holistic psychological and psychosocial considerations, and effective and long-lasting outcome.
CASA-Mot in mammals: an update.
Yániz, J L; Silvestre, M A; Santolaria, P; Soler, C
2018-03-08
Sperm motility is one of the most widely used parameters of sperm quality. Computer-aided sperm motility analysis (CASA-Mot) systems were developed to reduce the subjectivity of sperm motility assessment, and have had broad scientific and practical acceptance. In this review, the sources of variation and current applications of this technology and its relationships with other sperm quality tests are described in detail. Despite remarkable advances in the technique, there is still great need for standardisation in many species, and the numerous factors that affect the results make it difficult to provide universally accepted criteria for classifying semen samples based on sperm motility characteristics. The main fields for CASA-Mot include the study of male fertility and pathologies, evaluation of the effects of physical and chemical agents, improvement of epidemiological survey studies, more precise calculation of seminal doses for farm animals, realisation of basic studies about sperm function, improvement of sperm technologies such as cryopreservation and quality control analysis. Numerous relationships have been established between CASA-Mot and other sperm quality tests, although most of these parameters are complementary. Future CASA-Mot systems will probably be able to integrate several sperm quality parameters with motility.
Fatigue acceptance test limit criterion for larger diameter rolled thread fasteners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kephart, A.R.
1997-05-01
This document describes a fatigue lifetime acceptance test criterion by which studs having rolled threads, larger than 1.0 inches in diameter, can be assured to meet minimum quality attributes associated with a controlled rolling process. This criterion is derived from a stress dependent, room temperature air fatigue database for test studs having a 0.625 inch diameter threads of Alloys X-750 HTH and direct aged 625. Anticipated fatigue lives of larger threads are based on thread root elastic stress concentration factors which increase with increasing thread diameters. Over the thread size range of interest, a 30% increase in notch stress ismore » equivalent to a factor of five (5X) reduction in fatigue life. The resulting diameter dependent fatigue acceptance criterion is normalized to the aerospace rolled thread acceptance standards for a 1.0 inch diameter, 0.125 inch pitch, Unified National thread with a controlled Root radius (UNR). Testing was conducted at a stress of 50% of the minimum specified material ultimate strength, 80 Ksi, and at a stress ratio (R) of 0.10. Limited test data for fastener diameters of 1.00 to 2.25 inches are compared to the acceptance criterion. Sensitivity of fatigue life of threads to test nut geometry variables was also shown to be dependent on notch stress conditions. Bearing surface concavity of the compression nuts and thread flank contact mismatch conditions can significantly affect the fastener fatigue life. Without improved controls these conditions could potentially provide misleading acceptance data. Alternate test nut geometry features are described and implemented in the rolled thread stud specification, MIL-DTL-24789(SH), to mitigate the potential effects on fatigue acceptance data.« less
NASA Astrophysics Data System (ADS)
Zhao, Y.; Zhang, L.; Ma, W.; Zhang, P.; Zhao, T.
2018-04-01
The First National Geographical Condition Survey is a predecessor task to dynamically master basic situations of the nature, ecology and human activities on the earth's surface and it is the brand-new mapping geographic information engineering. In order to ensure comprehensive, real and accurate survey results and achieve the quality management target which the qualified rate is 100 % and the yield is more than 80 %, it is necessary to carry out the quality control and result inspection for national geographical conditions survey on a national scale. To ensure that achievement quality meets quality target requirements, this paper develops the key technology method of "five-in-one" quality control that is constituted by "quality control system of national geographical condition survey, quality inspection technology system, quality evaluation system, quality inspection information management system and national linked quality control institutions" by aiming at large scale, wide coverage range, more undertaking units, more management levels, technical updating, more production process and obvious regional differences in the national geographical condition survey and combining with novel achievement manifestation, complicated dependency, more special reference data, and large data size. This project fully considering the domestic and foreign related research results and production practice experience, combined with the technology development and the needs of the production, it stipulates the inspection methods and technical requirements of each stage in the quality inspection of the geographical condition survey results, and extends the traditional inspection and acceptance technology, and solves the key technologies that are badly needed in the first national geographic survey.
Spielberg, Freya; Kurth, Ann; Reidy, William; McKnight, Teka; Dikobe, Wame; Wilson, Charles
2011-06-01
This article highlights findings from an evaluation that explored the impact of mobile versus clinic-based testing, rapid versus central-lab based testing, incentives for testing, and the use of a computer counseling program to guide counseling and automate evaluation in a mobile program reaching people of color at risk for HIV. The program's results show that an increased focus on mobile outreach using rapid testing, incentives and health information technology tools may improve program acceptability, quality, productivity and timeliness of reports. This article describes program design decisions based on continuous quality assessment efforts. It also examines the impact of the Computer Assessment and Risk Reduction Education computer tool on HIV testing rates, staff perception of counseling quality, program productivity, and on the timeliness of evaluation reports. The article concludes with a discussion of implications for programmatic responses to the Centers for Disease Control and Prevention's HIV testing recommendations.
Spielberg, Freya; Kurth, Ann; Reidy, William; McKnight, Teka; Dikobe, Wame; Wilson, Charles
2016-01-01
This article highlights findings from an evaluation that explored the impact of mobile versus clinic-based testing, rapid versus central-lab based testing, incentives for testing, and the use of a computer counseling program to guide counseling and automate evaluation in a mobile program reaching people of color at risk for HIV. The program’s results show that an increased focus on mobile outreach using rapid testing, incentives and health information technology tools may improve program acceptability, quality, productivity and timeliness of reports. This article describes program design decisions based on continuous quality assessment efforts. It also examines the impact of the Computer Assessment and Risk Reduction Education computer tool on HIV testing rates, staff perception of counseling quality, program productivity, and on the timeliness of evaluation reports. The article concludes with a discussion of implications for programmatic responses to the Centers for Disease Control and Prevention’s HIV testing recommendations. PMID:21689041
Physical ACtivity facilitation for Elders (PACE): study protocol for a randomised controlled trial.
Morgan, Gemma S; Haase, Anne M; Campbell, Rona; Ben-Shlomo, Yoav
2015-03-13
As people live longer, their risk of disability increases. Disability affects quality of life and increases health and social care costs. Preventing or delaying disability is therefore an important objective, and identifying an effective intervention could improve the lives of many older people. Observational and interventional evidence suggests that physical activity may reduce the risk of age-related disability, as assessed by physical performance measures. However it is unclear what approach is the most cost-effective intervention in changing long-term physical activity behaviour in older adults. A new theory-driven behavioural intervention has been developed, with the aim of increasing physical activity in the everyday lives of older adults at risk of disability. This pilot study tests the feasibility and acceptability of delivering this intervention to older adults. A randomised controlled trial (RCT) design will be used in the pilot study. Sixty patients aged 65 years and older will be recruited from primary care practices. Patients will be eligible to participate if they are inactive, not disabled at baseline, are at risk of developing disability in the future (Short Physical Performance Battery score <10/12), and have no contraindications to physical activity. Following baseline measures, participants will be randomised in a 2:1 ratio to the intervention or to a control arm and all participants will be followed-up after 6 months. Those randomised to the intervention arm will receive sessions with a trained Physical Activity Facilitator, delivering an intervention based on self-determination theory. Control participants receive a booklet on healthy ageing. The main outcomes of interest are recruitment, adherence, retention and acceptability. Data will also be collected on: self-report and accelerometer-recorded physical activity; physical performance; depression; wellbeing; cognitive function; social support; quality of life, healthcare use, and attitudes to physical activity. A mixed-methods process evaluation will run alongside the RCT. The intervention, if effective, has the potential to reduce disability and improve quality of life in older adults. Before proceeding to a full-scale trial a pilot trial is necessary to ensure intervention feasibility and acceptability, and that the intervention shows evidence of promise. Current Controlled Trials ISRCTN80470273 . Registered 25 October 2013.
NASA Technical Reports Server (NTRS)
Urie, D. M.
1979-01-01
Relaxed static stability and stability augmentation with active controls were investigated for subsonic transport aircraft. Analytical and simulator evaluations were done using a contemporary wide body transport as a baseline. Criteria for augmentation system performance and unaugmented flying qualities were evaluated. Augmentation control laws were defined based on selected frequency response and time history criteria. Flying qualities evaluations were conducted by pilots using a moving base simulator with a transport cab. Static margin and air turbulence intensity were varied in test with and without augmentation. Suitability of a simple pitch control law was verified at neutral static margin in cruise and landing flight tasks. Neutral stability was found to be marginally acceptable in heavy turbulence in both cruise and landing conditions.
Frandes, Mirela; Deiac, Anca V; Timar, Bogdan; Lungeanu, Diana
2017-01-01
Nowadays, mobile technologies are part of everyday life, but the lack of instruments to assess their acceptability for the management of chronic diseases makes their actual adoption for this purpose slow. The objective of this study was to develop a survey instrument for assessing patients' attitude toward and intention to use mobile technology for diabetes mellitus (DM) self-management, as well as to identify sociodemographic characteristics and quality of life factors that affect them. We first conducted the documentation and instrument design phases, which were subsequently followed by the pilot study and instrument validation. Afterward, the instrument was administered 103 patients (median age: 37 years; range: 18-65 years) diagnosed with type 1 or type 2 DM, who accepted to participate in the study. The reliability and construct validity were assessed by computing Cronbach's alpha and using factor analysis, respectively. The instrument included statements about the actual use of electronic devices for DM management, interaction between patient and physician, attitude toward using mobile technology, and quality of life evaluation. Cronbach's alpha was 0.9 for attitude toward using mobile technology and 0.97 for attitude toward using mobile device applications for DM self-management. Younger patients (Spearman's ρ =-0.429; P <0.001) with better glycemic control (Spearman's ρ =-0.322; P <0.001) and higher education level (Kendall's τ =0.51; P <0.001) had significantly more favorable attitude toward using mobile assistive applications for DM control. Moreover, patients with a higher quality of life presented a significantly more positive attitude toward using modern technology (Spearman's ρ =0.466; P <0.001). The instrument showed good reliability and internal consistency, making it suitable for measuring the acceptability of mobile technology for DM self-management. Additionally, we found that even if most of the patients showed positive attitude toward mobile applications, only a moderate level of intention to indeed use them was observed. Moreover, the study indicated that barriers were truthfulness and easiness to use.
Preliminary simulation of an advanced, hingless rotor XV-15 tilt-rotor aircraft
NASA Technical Reports Server (NTRS)
Mcveigh, M. A.
1976-01-01
The feasibility of the tilt-rotor concept was verified through investigation of the performance, stability and handling qualities of the XV-15 tilt rotor. The rotors were replaced by advanced-technology fiberglass/composite hingless rotors of larger diameter, combined with an advanced integrated fly-by-wire control system. A parametric simulation model of the HRXV-15 was developed, model was used to define acceptable preliminary ranges of primary and secondary control schedules as functions of the flight parameters, to evaluate performance, flying qualities and structural loads, and to have a Boeing-Vertol pilot conduct a simulated flight test evaluation of the aircraft.
Possible environmental effects of increased coal use in California
NASA Technical Reports Server (NTRS)
Carey, D. L.
1978-01-01
If coal is to be utilized in California it must be made compatible with the state's drive toward restoring environmental quality. The impacts resulting from coal's mining and transportation, or from water consumption, water quality degradation and electric transmission line routing can probably be adequately mitigated through strong and early planning efforts, the use of improved control and process technologies, and sincere utility commitment. The socioeconomic impacts may prove somewhat more difficult to satisfactorily mitigate. Of greatest concern is adequate control of generated air pollutants and disposal of solid and liquid wastes since acceptable technologies or handling techniques have yet to be conclusively demonstrated.
Chen, Ming-Shu; Wu, Ming-Hsun; Lin, Chih-Ming
2014-04-30
The traditional criteria for acceptability of analytic quality may not be objective in clinical laboratories. To establish quality control procedures intended to enhance Westgard multi-rules for improving the quality of clinical biochemistry tests, we applied the Cp and Cpk quality-control indices to monitor tolerance fitting and systematic variation of clinical biochemistry test results. Daily quality-control data of a large Taiwanese hospital in 2009 were analyzed. The test items were selected based on an Olympus biochemistry machine and included serum albumin, aspartate aminotransferase, cholesterol, glucose and potassium levels. Cp and Cpk values were calculated for normal and abnormal levels, respectively. The tolerance range was estimated with data from 50 laboratories using the same instruments and reagents. The results showed a monthly trend of variation for the five items under investigation. The index values of glucose were lower than those of the other items, and their values were usually <2. In contrast to the Cp value for cholesterol, Cpk of cholesterol was lower than 2, indicating a systematic error that should be further investigated. This finding suggests a degree of variation or failure to meet specifications that should be corrected. The study indicated that Cp and Cpk could be applied not only for monitoring variations in quality control, but also for revealing inter-laboratory qualitycontrol capability differences.
Ejigu Tafere, Tadese; Afework, Mesganaw Fanthahun; Yalew, Alemayehu Worku
2018-01-01
In Ethiopia, more than 62% of pregnant women attend antenatal care at least once, yet only about one in four women give birth at health facility. This gap has fueled the need to investigate on the quality of ANC services at public health facilities and its link with the use of institutional delivery. To assess the linkage between ANC quality and the use of institutional delivery among pregnant women attending ANC at public health facilities of BDR City Administration. A facility based prospective follow up study was conducted. and nine hundred seventy pregnant women with gestational age ≤ 16 weeks who came for their first ANC visit were enrolled.Women were followed from their first ANC visit until delivery. Longitudinal data was collected during consultation with ANC providers using structured observation checklist. ANC service was considered as acceptable quality if women received ≥75th percentile of the essential ANC services. Generalized Estimating Equation (GEE) was carried out to control cluster effect among women who received ANC in the same facility. Among 823 pregnant women who completed follow up, only about one third (27.6%) received acceptable quality of ANC services. In one health facility syphilis test was not done at all for the last two years. The odds of giving birth at health institution among pregnant women who received acceptable ANC quality service was about 3.38 times higher than among pregnant women who received unacceptable ANC quality service (AOR = 3.38, 95% CI: 1.67, 6.83). In this study the quality of ANC service provision in public health facilities was compromised/low. Provision of quality ANC service had a great role in promoting institutional delivery. Therefore the local authorities at each level of health sector or the nongovernmental organizations working to improve maternal health need to provide training on focused antenatal care protocol for ANC providers.
Afework, Mesganaw Fanthahun; Yalew, Alemayehu Worku
2018-01-01
Background In Ethiopia, more than 62% of pregnant women attend antenatal care at least once, yet only about one in four women give birth at health facility. This gap has fueled the need to investigate on the quality of ANC services at public health facilities and its link with the use of institutional delivery. Objective To assess the linkage between ANC quality and the use of institutional delivery among pregnant women attending ANC at public health facilities of BDR City Administration Methods A facility based prospective follow up study was conducted. and nine hundred seventy pregnant women with gestational age ≤ 16 weeks who came for their first ANC visit were enrolled.Women were followed from their first ANC visit until delivery. Longitudinal data was collected during consultation with ANC providers using structured observation checklist. ANC service was considered as acceptable quality if women received ≥75th percentile of the essential ANC services. Generalized Estimating Equation (GEE) was carried out to control cluster effect among women who received ANC in the same facility. Results Among 823 pregnant women who completed follow up, only about one third (27.6%) received acceptable quality of ANC services. In one health facility syphilis test was not done at all for the last two years. The odds of giving birth at health institution among pregnant women who received acceptable ANC quality service was about 3.38 times higher than among pregnant women who received unacceptable ANC quality service (AOR = 3.38, 95% CI: 1.67, 6.83). Conclusion and recommendation In this study the quality of ANC service provision in public health facilities was compromised/low. Provision of quality ANC service had a great role in promoting institutional delivery. Therefore the local authorities at each level of health sector or the nongovernmental organizations working to improve maternal health need to provide training on focused antenatal care protocol for ANC providers. PMID:29420598
Sexual Function Is Correlated With Body Image and Partnership Quality in Female University Students.
Wallwiener, Stephanie; Strohmaier, Jana; Wallwiener, Lisa-Maria; Schönfisch, Birgitt; Zipfel, Stephan; Brucker, Sara Y; Rietschel, Marcella; Wallwiener, Christian W
2016-10-01
According to the World Health Organization definition, sexual health is more than mere physical sexual function; it also encompasses emotional, mental, and social well-being in relation to sexuality and is not merely the absence of dysfunction or disease. In line with this definition, various studies have reported that female sexual function is associated with partnership quality, body image, and body self-acceptance. To investigate whether female sexual function is influenced by (i) body self-acceptance and (ii) partnership quality, as important factors in psychosocial well-being, and (iii) whether the effects of body self-acceptance are moderated by partnership quality. In total, 2,685 female medical students no older than 35 years from Germany, Austria, and Switzerland completed an anonymous online questionnaire comprising the Female Sexual Function Index (FSFI) and the Self-Acceptance of the Body Scale. Respondents were asked to state whether they had been in a steady partnership in the preceding 6 months. When present, the quality of the partnership status was rated (enamoredness, love, friendship, or conflicted). To determine correlations, group differences, and moderating effects among body self-acceptance, partnership quality, and sexual function, the data were analyzed using Spearman correlations, Kruskal-Wallis tests, and analyses of variance. Female sexual function (FSFI total score). (i) In sexually active women, higher FSFI scores were significantly associated with greater body self-acceptance and a steady partnership during the preceding 6 months. (ii) Total FSFI scores were highest in women who described their partnership as enamored (29.45) or loving (28.55). Lower scores were observed in single women (26.71) and in women who described their partnerships as friendship (25.76) or as emotionally conflicted (23.41). (iii) Total FSFI score was affected by an interaction between body self-acceptance and partnership quality. Body self- acceptance was positively associated with FSFI total scores, particularly in single women and women in emotionally conflicted partnerships. Our findings suggest that in young women, body self-acceptance and partnership quality are positively associated with better sexual function, and that high body self-acceptance might buffer the negative impact on sexual function of partnership quality. The present data suggest that psychological interventions to improve the body image of younger women can positively affect sexual function and thereby improve sexual health. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
Control of forward swept wing configurations dominated by flight-dynamic/aeroelastic interactions
NASA Technical Reports Server (NTRS)
Rimer, M.; Chipman, R.; Muniz, B.
1984-01-01
An active control system concept for an aeroelastic wind-tunnel model of a statically unstable FSW configuration with wing-mounted stores is developed to provide acceptable longitudinal flying qualities while maintaining adequate flutter speed margin. On FSW configurations, the inherent aeroelastic wing divergence tendency causes strong flight-dynamic/aeroelastic interactions that in certain cases can produce a dynamic instability known as body-freedom flutter (BFF). The carriage of wing-mounted stores is shown to severely aggravate this problem. The control system developed combines a canard-based SAS with an Active Divergence/Flutter Suppression (ADFS) system which relies on wing-mounted sensors and a trailing-edge device (flaperon). Synergism between these two systems is exploited to obtain the flying qualities and flutter speed objectives.
Contact Analog/Compressed Symbology Heading Tape Assessment
NASA Technical Reports Server (NTRS)
Shively, R. Jay; Atencio, Adolph; Turpin, Terry; Dowell, Susan
2002-01-01
A simulation assessed the performance, handling qualities and workload associated with a contact-analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a screen-fixed, compressed heading tape. Six pilots, four active duty Army Aviators and two civilians flew three ADS-33 maneuvers and a traffic pattern in the Ames Vertical Motion Simulation facility. Small, but statistically significant advantages were found for the compressed symbology for handling qualities, workload, and some of the performance measures. It should be noted however that the level of performance and handling qualities for both symbology sets fell within the acceptable tolerance levels. Both symbology sets yield satisfactory handling qualities and performance in velocity stabilization mode and adequate handling qualities in the automatic flight control mode. Pilot comments about the contact analog symbology highlighted the lack of useful rate of change information in the heading tape and "blurring" due to the rapid movement of the heading tape. These issues warrant further study. Care must be taken in interpreting the operational significance of these results. The symbology sets yielded categorically similar data, i.e., acceptable handling qualities and adequate performance, so while the results point to the need for further study, their operational significance has yet to be determined.
Resource quality or competition: why increase resource acceptance in the presence of conspecifics?
Nufio, César R.; Papaj, Daniel R.
2011-01-01
Some animal species increase resource acceptance rates in the presence of conspecifics. Such responses may be adaptive if the presence of conspecifics is a reliable indicator of resource quality. Similarly, these responses could represent an adaptive reduction in choosiness under high levels of scramble competition. Although high resource quality and high levels of scramble competition should both favor increased resource acceptance, the contexts in which the increase occurs should differ. In this paper, we tested the effect of social environment on egg-laying and aggressive behavior in the walnut fly, Rhagoletis juglandis, in multiple contexts to determine whether increased resource acceptance in the presence of conspecifics was better viewed as a response to increased host quality or increased competition. We found that grouped females oviposit more readily than isolated females when provided small (low-quality) artificial hosts but not when provided large (high-quality) artificial hosts, indicating that conspecific presence reduces choosiness. Increased resource acceptance was observed even when exposure to conspecifics was temporally or spatially separate from exposure to the resource. Finally, we found that individuals showed reduced aggression after being housed in groups, as expected under high levels of scramble competition. These results indicate that the pattern of resource acceptance in the presence of conspecifics may be better viewed as a response to increased scramble competition rather than as a response to public information about resource quality. PMID:22479135
Resource quality or competition: why increase resource acceptance in the presence of conspecifics?
Davis, Jeremy M; Nufio, César R; Papaj, Daniel R
2011-07-01
Some animal species increase resource acceptance rates in the presence of conspecifics. Such responses may be adaptive if the presence of conspecifics is a reliable indicator of resource quality. Similarly, these responses could represent an adaptive reduction in choosiness under high levels of scramble competition. Although high resource quality and high levels of scramble competition should both favor increased resource acceptance, the contexts in which the increase occurs should differ. In this paper, we tested the effect of social environment on egg-laying and aggressive behavior in the walnut fly, Rhagoletis juglandis, in multiple contexts to determine whether increased resource acceptance in the presence of conspecifics was better viewed as a response to increased host quality or increased competition. We found that grouped females oviposit more readily than isolated females when provided small (low-quality) artificial hosts but not when provided large (high-quality) artificial hosts, indicating that conspecific presence reduces choosiness. Increased resource acceptance was observed even when exposure to conspecifics was temporally or spatially separate from exposure to the resource. Finally, we found that individuals showed reduced aggression after being housed in groups, as expected under high levels of scramble competition. These results indicate that the pattern of resource acceptance in the presence of conspecifics may be better viewed as a response to increased scramble competition rather than as a response to public information about resource quality.
Acceptance of disease and the quality of life in patients with enteric stoma.
Szpilewska, Katarzyna; Juzwiszyn, Jan; Bolanowska, Zofia; Bolanowska, Zofia; Milan, Magdalena; Chabowski, Mariusz; Janczak, Dariusz
2018-02-28
The main reason of the emergence of enteric stoma is colorectal cancer. Enteric stoma is a serious health, as well as life problem. In Poland, there are about 6,000 stoma surgeries yearly. It changes the functioning of patients, restricts their daily activity and influences their quality of life significantly. Therefore, in the modern treatment process, all spheres of human life and its surroundings are considered. The evaluation of the quality of life and the level of acceptance of the disease enables us to identify the regions in which patients require attention and help, as well as places to which health promotion among patients with a stoma should be directed. The aim of the study was the evaluation of the acceptance of the disease and the quality of life in patients with colostomy. The study conducted between February 2015 and February 2016 included101 patients with enteric stoma of the Provincial Specialist Hospital in Wrocław at Kamieńskiego St. in the departments of General Surgery with the Subdivision of Traumatology and Orthopedic Surgery, Subdivision of Metabolic Surgery, Subdivision of Endocrine Surgery and Oncological Surgery . Two anonymous questionnaires, i.e., health-related quality of life (HRQoL) and acceptance of illness scale (AIS), were used. 60% (61 people) were women, and 40% (40 people) were men. The mean age was 48; the youngest respondent was 20 years old, and the oldest was 79 years old. 17% of the respondents had primary education, 25% - vocational, 33% - secondary and 26% - university-level. The most common reason for the emergence of a stoma among the respondents was colon cancer (44%), followed by: mechanical bowel onstruction (26%), intestinal damage following injuries (25%), inflammatory bowel disease (6%). The quality of life of patients with colostomy was evaluated in view of their health condition, postoperative recovery, everyday limitations, and self-evaluation. The majority of participants pointed to the deterioration of their quality of life. A higher level of acceptance of the disease was revealed in men as 75% of men, and 61% of women acceptted their health status. The education level also influences the acceptance of the disease, as 41% participants with higher education, and only 6% participants with primary education did not accept their health status. We revealed some social factors influencing the quality of life and the acceptance of the disease, i.e., gender, age, education, job, and place of living. Gender and education have an impact on the level of the acceptance of the disease, but they do not influence the quality of life. The acceptance of the disease is connected with the quality of life in patients with a stoma. The higher the level of acceptance of the disease, the better the quality of life. Research indicates the need to deepen patients' education regarding their functioning in society.
Chiumarelli, Marcela; Pereira, Leila M; Ferrari, Cristhiane C; Sarantópoulos, Claire I G L; Hubinger, Miriam D
2010-06-01
Combination of citric acid dipping (5 g/L) and cassava starch coating (10 g/L), with and without glycerol (10 g/L), was studied to verify the effectiveness of these treatments to inhibit enzymatic browning, to reduce respiration rate, and to preserve quality parameters of "Tommy Atkins" fresh-cut mangoes during storage at 5 degrees C. Color characteristics (L and C), mechanical properties (stress at failure), weight loss, beta-carotene content, sensory acceptance, and microbial growth of fruits were evaluated during 15 d. The respiration rate of fruit subjected to the treatments was also analyzed. Nontreated fresh-cut mango was used as a control sample. Cassava starch edible coatings and citric acid dipping promoted a decrease in respiration rate of mango slices, with values up to 41% lower than the control fruit. This treatment also promoted better preservation of texture and color characteristics of mangoes and delayed carotenoid formation and browning reactions during storage. Moreover, the treated fruit showed great sensory acceptance by consumers throughout the whole storage period. However, the use of glycerol in the coating formulation was not efficient in the maintenance of quality parameters of fresh-cut mangoes, promoting a higher weight loss of samples, impairing fruit texture characteristics, increasing carotenogenesis, and favoring microbial growth during storage.
Specification for wide channel bandwidth one-inch video tape
NASA Technical Reports Server (NTRS)
Perry, Jimmy L.
1988-01-01
Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.
dos Santos, Bruno César Diniz Brito; Flumignan, Danilo Luiz; de Oliveira, José Eduardo
2012-10-01
A three-step development, optimization and validation strategy is described for gas chromatography (GC) fingerprints of Brazilian commercial diesel fuel. A suitable GC-flame ionization detection (FID) system was selected to assay a complex matrix such as diesel. The next step was to improve acceptable chromatographic resolution with reduced analysis time, which is recommended for routine applications. Full three-level factorial designs were performed to improve flow rate, oven ramps, injection volume and split ratio in the GC system. Finally, several validation parameters were performed. The GC fingerprinting can be coupled with pattern recognition and multivariate regressions analyses to determine fuel quality and fuel physicochemical parameters. This strategy can also be applied to develop fingerprints for quality control of other fuel types.
33 CFR 159.317 - Sampling and reporting.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Sampling and reporting. 159.317... Operations § 159.317 Sampling and reporting. (a) The owner, operator, master or other person in charge of a.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...
33 CFR 159.317 - Sampling and reporting.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Sampling and reporting. 159.317... Operations § 159.317 Sampling and reporting. (a) The owner, operator, master or other person in charge of a.../Quality Control Plan (QA/QCP) accepted by the COTP for sampling and analysis of treated sewage and/or...
Code of Federal Regulations, 2010 CFR
2010-07-01
... EDUCATION, DEPARTMENT OF EDUCATION TEACHER QUALITY ENHANCEMENT GRANTS PROGRAM Scholarships § 611.45 Under... on information acceptable to the Secretary of— (1) The recipient's death; or (2) The total and... discharge was approved. (Approved by the Office of Management and Budget under control number 1840-0753...
Saturn S-2 quality assurance techniques, critical process control. Volume 7: Metallic materials
NASA Technical Reports Server (NTRS)
Ross, W. D., Jr.
1970-01-01
The special skills developed during the Saturn S-2 Program are documented to enable qualified personnel to carry out efficient operations in future S-2 production. Skills covered include: acceptance testing of fusion-welding equipment, weld operators and inspector certification, machine certification, preweld operations, and repair weld certification.
49 CFR 236.1015 - PTC Safety Plan content requirements and PTC System Certification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... established and can maintain a quality control system for PTC system design and manufacturing acceptable to... an explanation of the design principles and assumptions; (3) A risk assessment of the as-built PTC... the specific procedures and test equipment necessary to ensure the safe and proper installation...
24 CFR 902.64 - PHAS scoring and audit reviews.
Code of Federal Regulations, 2011 CFR
2011-04-01
... necessary as a result of the independent public accountant (IPA) audit. (2) Each PHA (or RMC) shall post a... review. HUD may undertake a quality control review of the audit work papers or as part of the Department... Attestation Engagements issued by the American Institute of Certified Public Accountants or Generally Accepted...
24 CFR 902.64 - PHAS scoring and audit reviews.
Code of Federal Regulations, 2012 CFR
2012-04-01
... necessary as a result of the independent public accountant (IPA) audit. (2) Each PHA (or RMC) shall post a... review. HUD may undertake a quality control review of the audit work papers or as part of the Department... Attestation Engagements issued by the American Institute of Certified Public Accountants or Generally Accepted...
24 CFR 902.64 - PHAS scoring and audit reviews.
Code of Federal Regulations, 2014 CFR
2014-04-01
... necessary as a result of the independent public accountant (IPA) audit. (2) Each PHA (or RMC) shall post a... review. HUD may undertake a quality control review of the audit work papers or as part of the Department... Attestation Engagements issued by the American Institute of Certified Public Accountants or Generally Accepted...
24 CFR 902.64 - PHAS scoring and audit reviews.
Code of Federal Regulations, 2013 CFR
2013-04-01
... necessary as a result of the independent public accountant (IPA) audit. (2) Each PHA (or RMC) shall post a... review. HUD may undertake a quality control review of the audit work papers or as part of the Department... Attestation Engagements issued by the American Institute of Certified Public Accountants or Generally Accepted...
Acoustic measurements on trees and logs: a review and analysis
Xiping Wang
2013-01-01
Acoustic technologies have been well established as material evaluation tools in the past several decades, and their use has become widely accepted in the forest products industry for online quality control and products grading. Recent research developments on acoustic sensing technology offer further opportunities to evaluate standing trees and logs for general wood...
Code of Federal Regulations, 2011 CFR
2011-07-01
... EDUCATION, DEPARTMENT OF EDUCATION TEACHER QUALITY ENHANCEMENT GRANTS PROGRAM Scholarships § 611.45 Under... on information acceptable to the Secretary of— (1) The recipient's death; or (2) The total and... discharge was approved. (Approved by the Office of Management and Budget under control number 1840-0753...
Ruberu, S R; Langlois, G W; Masuda, M; Perera, S Kusum
2012-01-01
The receptor-binding assay (RBA) method for determining saxatoxin (STX) and its numerous analogues, which cause paralytic shellfish poisoning (PSP) in humans, was evaluated in a single laboratory study. Each step of the assay preparation procedure including the performance of the multi-detector TopCount® instrument was evaluated for its contribution to method variability. The overall inherent RBA variability was determined to be 17%. Variability within the 12 detectors was observed; however, there was no reproducible pattern in detector performance. This observed variability among detectors could be attributed to other factors, such as pipetting errors. In an attempt to reduce the number of plates rejected due to excessive variability in the method's quality control parameters, a statistical approach was evaluated using either Grubbs' test or the Student's t-test for rejecting outliers in the measurement of triplicate wells. This approach improved the ratio of accepted versus rejected plates, saving cost and time for rerunning the assay. However, the potential reduction in accuracy and the lack of improvement in precision suggests caution when using this approach. The current study has recommended an alternate quality control procedure for accepting or rejecting plates in place of the criteria currently used in the published assay, or the alternative of outlier testing. The recommended procedure involves the development of control charts to monitor the critical parameters identified in the published method (QC sample, EC₅₀, slope of calibration curve), with the addition of a fourth critical parameter which is the top value (100% binding) of the calibration curve.
Brunie, Aurélie; Wamala-Mucheri, Patricia; Akol, Angela; Mercer, Sarah; Chen, Mario
2016-10-01
Improving HIV testing and counselling (HTC) requires a range of strategies. This article reports on HTC service delivery by Village Health Teams (VHTs) in Uganda in the context of a model integrating this new component into pre-existing family planning services. Eight health centres from matched pairs were randomly allocated to intervention or control. After being trained, 36 VHTs reporting to selected facilities in the intervention group started offering HTC along with family planning, while VHTs in the control group provided family planning only. Proficiency testing was conducted as external quality assurance. A survey of all 36 VHTs and 137 family planning clients in the intervention group and 119 clients in the control group and a review of record data were conducted after 10 months. Survey responses by VHTs and their clients in the intervention group demonstrate knowledge of counselling messages and safe testing. External quality assessment results provide additional evidence of competency. Eighty per cent of the family planning clients surveyed in the intervention group received an HIV test during the intervention; 27% of those were first-time testers. More clients had ever tested for HIV in the intervention group compared with the control; clients also retested more often. Findings indicate that this model is feasible and acceptable for expanding quality HTC into communities. This study was registered with ClinicalTrials.gov, number [NCT02244398]. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Scanning technology selection impacts acceptability and usefulness of image-rich content.
Alpi, Kristine M; Brown, James C; Neel, Jennifer A; Grindem, Carol B; Linder, Keith E; Harper, James B
2016-01-01
Clinical and research usefulness of articles can depend on image quality. This study addressed whether scans of figures in black and white (B&W), grayscale, or color, or portable document format (PDF) to tagged image file format (TIFF) conversions as provided by interlibrary loan or document delivery were viewed as acceptable or useful by radiologists or pathologists. Residency coordinators selected eighteen figures from studies from radiology, clinical pathology, and anatomic pathology journals. With original PDF controls, each figure was prepared in three or four experimental conditions: PDF conversion to TIFF, and scans from print in B&W, grayscale, and color. Twelve independent observers indicated whether they could identify the features and whether the image quality was acceptable. They also ranked all the experimental conditions of each figure in terms of usefulness. Of 982 assessments of 87 anatomic pathology, 83 clinical pathology, and 77 radiology images, 471 (48%) were unidentifiable. Unidentifiability of originals (4%) and conversions (10%) was low. For scans, unidentifiability ranged from 53% for color, to 74% for grayscale, to 97% for B&W. Of 987 responses about acceptability (n=405), 41% were said to be unacceptable, 97% of B&W, 66% of grayscale, 41% of color, and 1% of conversions. Hypothesized order (original, conversion, color, grayscale, B&W) matched 67% of rankings (n=215). PDF to TIFF conversion provided acceptable content. Color images are rarely useful in grayscale (12%) or B&W (less than 1%). Acceptability of grayscale scans of noncolor originals was 52%. Digital originals are needed for most images. Print images in color or grayscale should be scanned using those modalities.
Assessing landowners' attitudes toward wild hogs and support for control options.
Caplenor, Carlotta A; Poudyal, Neelam C; Muller, Lisa I; Yoest, Chuck
2017-10-01
Wild hogs (Sus scrofa) are an invasive species with destructive habits, particularly rooting and wallowing, which can directly impact agricultural crops, pasture land, and water quality. Considering wild hogs are widely dispersed across the landscape, they are extremely difficult to control. Disagreements can arise among different stakeholders over whether and how their populations should be managed. The purpose of this article was to examine Tennessee, United States landowners' attitudes toward wild hogs, to compare acceptability of control methods, and to evaluate factors significantly influencing public support for regulations to control wild hogs. Logistic regression was employed to analyze data collected from a statewide survey of rural landowners in the fall of 2015. Landowners had overwhelmingly negative attitudes towards wild hogs, and were concerned about their impact on the natural environment and rural economy. Although landowners showed support for controlling wild hogs, levels of acceptability for management options varied. Respondents favored active management and supported education and incentive-based control programs to control wild hogs. Cognitive concepts such as social and personal norms and awareness of consequences, as well as demographic characteristics, significantly predicted landowners' support for state regulations to control wild hogs in Tennessee. Findings increase our understanding of the human dimensions of wild hog management and that of other similarly invasive animals, and may guide resource managers in designing effective and socially acceptable management strategies to control wild hog populations in Tennessee and elsewhere. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Barufaldi, Bruno; Borges, Lucas R.; Bakic, Predrag R.; Vieira, Marcelo A. C.; Schiabel, Homero; Maidment, Andrew D. A.
2017-03-01
Automatic exposure control (AEC) is used in mammography to obtain acceptable radiation dose and adequate image quality regardless of breast thickness and composition. Although there are physics methods for assessing the AEC, it is not clear whether mammography systems operate with optimal dose and image quality in clinical practice. In this work, we propose the use of a normalized anisotropic quality index (NAQI), validated in previous studies, to evaluate the quality of mammograms acquired using AEC. The authors used a clinical dataset that consists of 561 patients and 1,046 mammograms (craniocaudal breast views). The results show that image quality is often maintained, even at various radiation levels (mean NAQI = 0.14 +/- 0.02). However, a more careful analysis of NAQI reveals that the average image quality decreases as breast thickness increases. The NAQI is reduced by 32% on average, when the breast thickness increases from 31 to 71 mm. NAQI also decreases with lower breast density. The variation in breast parenchyma alone cannot fully account for the decrease of NAQI with thickness. Examination of images shows that images of large, fatty breasts are often inadequately processed. This work shows that NAQI can be applied in clinical mammograms to assess mammographic image quality, and highlights the limitations of the automatic exposure control for some images.
Quality control and assurance for validation of DOS/I measurements
NASA Astrophysics Data System (ADS)
Cerussi, Albert; Durkin, Amanda; Kwong, Richard; Quang, Timothy; Hill, Brian; Tromberg, Bruce J.; MacKinnon, Nick; Mantulin, William W.
2010-02-01
Ongoing multi-center clinical trials are crucial for Biophotonics to gain acceptance in medical imaging. In these trials, quality control (QC) and assurance (QA) are key to success and provide "data insurance". Quality control and assurance deal with standardization, validation, and compliance of procedures, materials and instrumentation. Specifically, QC/QA involves systematic assessment of testing materials, instrumentation performance, standard operating procedures, data logging, analysis, and reporting. QC and QA are important for FDA accreditation and acceptance by the clinical community. Our Biophotonics research in the Network for Translational Research in Optical Imaging (NTROI) program for breast cancer characterization focuses on QA/QC issues primarily related to the broadband Diffuse Optical Spectroscopy and Imaging (DOS/I) instrumentation, because this is an emerging technology with limited standardized QC/QA in place. In the multi-center trial environment, we implement QA/QC procedures: 1. Standardize and validate calibration standards and procedures. (DOS/I technology requires both frequency domain and spectral calibration procedures using tissue simulating phantoms and reflectance standards, respectively.) 2. Standardize and validate data acquisition, processing and visualization (optimize instrument software-EZDOS; centralize data processing) 3. Monitor, catalog and maintain instrument performance (document performance; modularize maintenance; integrate new technology) 4. Standardize and coordinate trial data entry (from individual sites) into centralized database 5. Monitor, audit and communicate all research procedures (database, teleconferences, training sessions) between participants ensuring "calibration". This manuscript describes our ongoing efforts, successes and challenges implementing these strategies.
Noninvasive pH monitoring of platelet concentrates: a large field test.
Gkoumassi, Effimia; Klein-Bosgoed, Christa; Dijkstra-Tiekstra, Margriet J; de Korte, Dirk; de Wildt-Eggen, Janny
2013-10-01
Developing new quality control methods for platelet concentrates (PCs) can contribute to increasing transfusion safety and efficiency. The aim of this study was to investigate in a large field test the quality of expired PCs and whether 100% noninvasive pH monitoring can be used to predict PC quality. The pH of 13,693 PCs produced for transfusion was monitored daily using Blood Storage, Inc.'s pH sterile, automated fluoroscopic evaluation technology. Upon indication of compromised quality or expiration, PCs were returned and in vitro tests were performed. A total of 998 PCs were returned, of which 962 outdated, 26 had a positive BacT/ALERT reaction, seven had aggregates, one was without swirl, one had low pH, and one had high pH. BacT/ALERT was faster in identifying bacterial contamination than pH measurements. The pH at the end of the storage period was significantly lower than at the beginning. In vitro tests indicated that while the PC quality was acceptable upon expiration, it rapidly declined after expiration. In this setting where the vast majority of PCs were of good quality and within acceptable pH limits, daily, noninvasive routine pH measurement has limited added value in identifying quality-compromised PCs. © 2013 Sanquin Research. Transfusion © 2013 American Association of Blood Banks.
Outcome quality standards in pancreatic oncologic surgery in Spain.
Sabater, Luis; Mora, Isabel; Gámez Del Castillo, Juan Manuel; Escrig-Sos, Javier; Muñoz-Forner, Elena; Garcés-Albir, Marina; Dorcaratto, Dimitri; Ortega, Joaquín
2018-05-18
To establish quality standards in oncologic surgery is a complex but necessary challenge to improve surgical outcomes. Unlike other tumors, there are no well-defined quality standards in pancreatic cancer. The aim of this study is to identify quality indicators in pancreatic oncologic surgery in Spain as well as their acceptable limits of variability. Quality indicators were selected based on clinical practice guidelines, consensus conferences, reviews and national publications on oncologic pancreatic surgery between the years 2000 and 2016. Variability margins for each indicator have been determined by statistical process control techniques and graphically represented with the 99.8 and 95% confidence intervals above and below the weighted average according to sample size. The following indicators have been determined with their weighted average and acceptable quality limits: resectability rate 71% (>58%), morbidity 58% (<73%), mortality 4% (<10%), biliary leak 6% (<14%), pancreatic fistula rate 18% (<29%), hemorrhage 11% (<21%), reoperation rate 11% (<20%) and mean hospital stay (<21 days). To date, few related series have been published, and they present important methodological limitations. Among the selected indicators, the morbidity and mortality quality limits have come out higher than those obtained in international standards. It is necessary for Spanish pancreatic surgeons to adopt homogeneous criteria regarding indicators and their definitions to allow for the comparison of their results. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander; Sahu, Kusum
2003-01-01
Potential users of plastic encapsulated microcircuits (PEMs) need to be reminded that unlike the military system of producing robust high-reliability microcircuits that are designed to perform acceptably in a variety of harsh environments, PEMs are primarily designed for use in benign environments where equipment is easily accessed for repair or replacement. The methods of analysis applied to military products to demonstrate high reliability cannot always be applied to PEMs. This makes it difficult for users to characterize PEMs for two reasons: 1. Due to the major differences in design and construction, the standard test practices used to ensure that military devices are robust and have high reliability often cannot be applied to PEMs that have a smaller operating temperature range and are typically more frail and susceptible to moisture absorption. In contrast, high-reliability military microcircuits usually utilize large, robust, high-temperature packages that are hermetically sealed. 2. Unlike the military high-reliability system, users of PEMs have little visibility into commercial manufacturers proprietary design, materials, die traceability, and production processes and procedures. There is no central authority that monitors PEM commercial product for quality, and there are no controls in place that can be imposed across all commercial manufacturers to provide confidence to high-reliability users that a common acceptable level of quality exists for all PEMs manufacturers. Consequently, there is no guaranteed control over the type of reliability that is built into commercial product, and there is no guarantee that different lots from the same manufacturer are equally acceptable. And regarding application, there is no guarantee that commercial products intended for use in benign environments will provide acceptable performance and reliability in harsh space environments. The qualification and screening processes contained in this document are intended to detect poor-quality lots and screen out early random failures from use in space flight hardware. However, since it cannot be guaranteed that quality was designed and built into PEMs that are appropriate for space applications, users cannot screen in quality that may not exist. It must be understood that due to the variety of materials, processes, and technologies used to design and produce PEMs, this test process may not accelerate and detect all failure mechanisms. While the tests herein will increase user confidence that PEMs with otherwise unknown reliability can be used in space environments, such testing may not guarantee the same level of reliability offered by military microcircuits. PEMs should only be used where due to performance needs there are no alternatives in the military high-reliability market, and projects are willing to accept higher risk.
Acceptance and relationship context: a model of substance use disorder treatment outcome.
Gifford, Elizabeth V; Ritsher, Jennifer B; McKellar, John D; Moos, Rudolf H
2006-08-01
This study presented and tested a model of behavior change in long-term substance use disorder recovery, the acceptance and relationship context (ARC) model. The model specifies that acceptance-based behavior and constructive social relationships lead to recovery, and that treatment programs with supportive, involved relationships facilitate the development of these factors. This study used a prospective longitudinal naturalistic design and controlled for baseline levels of study variables. The model was tested on a sample of 2549 patients in 15 residential substance use disorder treatment programs. Acceptance-based responding (ABR), social relationship quality (SRQ), treatment program alliance (TPA) and substance use-related impairment were assessed using interviews and self-report questionnaires. TPA predicted ABR and SRQ and, in turn, ABR predicted better 2-year and 5-year treatment outcomes. The baseline-controlled model accounted for 41% of the variance in outcome at 2-year follow-up and 28% of the variance in outcome at 5-year follow-up. CONCLUSIONS Patients from treatment programs with an affiliative relationship network are more likely to respond adaptively to internal states associated previously with substance use, develop constructive social relationships and achieve long-term treatment benefits.
Bikmoradi, Ali; Masmouei, Behnam; Ghomeisi, Mohammad; Roshanaei, Ghodratollah; Masiello, Italo
2017-12-01
This study aimed to assess the impact of telephone counseling on quality of life in patients with coronary artery bypass graft. A quasi-experimental study was conducted with 71 discharged patients after coronary artery bypass graft surgery at Ekbatan Edcuational hospital in Hamadan, Iran, in 2014. The patients were randomly allocated into intervention (n=36) and control group (n=35). The intervention group received education and counseling about therapeutic plan via telephone after discharge. Patients in the control group received only routines. All patients completed the quality of life questionnaire before and after the intervention period of five weeks. There was no significant difference between intervention and control group about quality of life before intervention (p=0.696). However, there was significant and positive deference between the two groups in favor of the telephone counseling after the intervention (P=0.01) and control group (P=0.04). Quality of life in the intervention group was significantly better compared to control group (P=0.01). Telephone counseling could be a cost-effective patient counseling plan for therapeutic adherence after coronary artery bypass surgery in order to improve the patients' quality of life. Telephone counseling is feasible to implement and well accepted for patient counseling for many diseases. Copyright © 2017 Elsevier B.V. All rights reserved.
Guo, Ye; Chen, Qian; Wu, Wei; Cui, Wei
2015-03-31
To establish a system of monitoring the key indicator of quality for inspection (KIQI) on a laboratory information system (LIS), and to have a better management of KIQI. Clinical sample made in PUMCH were collected during the whole of 2014. Next, interactive input program were designed to accomplish data collecting of the disqualification rate of samples, the mistake rate of samples and the occasions of losing samples, etc. Then, a series moment of sample collection, laboratory sample arrived, sample test, sample check, response to critical value, namely, trajectory information left on LIS were recorded and the qualification rate of TAT, the notification rate of endangering result were calculated. Finally, the information about quality control were collected to build an internal quality control database and the KIQI, such as the out-of-control rate of quality control and the total error of test items were monitored. The inspection of the sample management shows the disqualification rates in 2014 were all below the target, but the rates in January and February were a little high and the rates of four wards were above 2%. The mistake rates of samples was 0.47 cases/10 000 cases, attaining the target (< 2 cases/10 000 cases). Also, there was no occasion of losing samples in 2014, attaining the target too. The inspection of laboratory reports shows the qualification rates of TAT was within the acceptable range (> 95%), however the rates of blood routine in November (94.75%) was out of range. We have solved the problem by optimizing the processes. The notification rate of endangering result attained the target (≥ 98%), while the rate of timely notification is needed to improve. Quality inspection shows the CV of APTT in August (5.02%) was rising significantly, beyond the accepted CV (5.0%). We have solved the problem by changing the reagent. The CV of TT in 2014 were all below the allowable CV, thus the allowable CV of the next year lower to 10%. It is an objective and effective method to manage KIQI with the powerful management mode of database and information process capability on LIS.
Antoniou, Stavros A; Andreou, Alexandros; Antoniou, George A; Koch, Oliver O; Köhler, Gernot; Luketina, Ruzica-R; Bertsias, Antonios; Pointner, Rudolph; Granderath, Frank-Alexander
2015-11-01
Measures have been taken to improve methodological quality of randomized controlled trials (RCTs). This review systematically assessed the trends in volume and methodological quality of RCTs on minimally invasive surgery within a 10-year period. RCTs on minimally invasive surgery were searched in the 10 most cited general surgical journals and the 5 most cited journals of laparoscopic interest for the years 2002 and 2012. Bibliometric and methodological quality components were abstracted using the Scottish Intercollegiate Guidelines Network. The pooled number of RCTs from low-contribution regions demonstrated an increasing proportion of the total published RCTs, compensating for a concomitant decrease of the respective contributions from Europe and North America. International collaborations were more frequent in 2012. Acceptable or high quality RCTs accounted for 37.9% and 54.4% of RCTs published in 2002 and 2012, respectively. Components of external validity were poorly reported. Both the volume and the reporting quality of laparoscopic RCTs have increased from 2002 to 2012, but there seems to be ample room for improvement of methodological quality. Copyright © 2015 Elsevier Inc. All rights reserved.
Controlled atmosphere storage of wild strawberry fruit (Fragaria vesca L.).
Almenar, Eva; Hernández-Muñoz, Pilar; Lagarón, José M; Catalá, Ramón; Gavara, Rafael
2006-01-11
Controlled atmosphere storage technology to extend the shelf life of "Reina de los Valles" wild strawberry fruit (Fragaria vesca L.) was studied. Fruits were stored at 3 degrees C for three weeks in different atmosphere compositions: 0.05% CO2/21% O2 (air), 3% CO2/18% O2, 6% CO2/15% O2, 10% CO2/11% O2, and 15% CO2/6% O2. The effect of gas composition on soluble solids content, titrable acidity, pH, off-flavor, aroma volatiles, and consumer preference was monitored. The result showed that the 10% CO2/11% O2 combination can efficiently prolong the shelf life of wild strawberries by maintaining the quality parameters within acceptable values, through inhibiting the development of Botrytis cinerea, without significantly modifying consumer acceptance.
Modified SPC for short run test and measurement process in multi-stations
NASA Astrophysics Data System (ADS)
Koh, C. K.; Chin, J. F.; Kamaruddin, S.
2018-03-01
Due to short production runs and measurement error inherent in electronic test and measurement (T&M) processes, continuous quality monitoring through real-time statistical process control (SPC) is challenging. Industry practice allows the installation of guard band using measurement uncertainty to reduce the width of acceptance limit, as an indirect way to compensate the measurement errors. This paper presents a new SPC model combining modified guard band and control charts (\\bar{\\text{Z}} chart and W chart) for short runs in T&M process in multi-stations. The proposed model standardizes the observed value with measurement target (T) and rationed measurement uncertainty (U). S-factor (S f) is introduced to the control limits to improve the sensitivity in detecting small shifts. The model was embedded in automated quality control system and verified with a case study in real industry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bond, Alan, E-mail: alan.bond@uea.ac.uk; Research Unit for Environmental Sciences and Management, North-West University; Fischer, Thomas B, E-mail: fischer@liverpool.ac.uk
The effectiveness of Environmental Impact Assessment (EIA) systems is contingent on a number of control mechanisms: procedural; judicial; evaluative; public and government agency; professional; and development aid agency. If we assume that procedural and judicial controls are guaranteed in developed EIA systems, then progressing effectiveness towards an acceptable level depends on improving the performance of other control mechanisms over time. These other control mechanisms are either absent, or are typically centrally controlled, requiring public finances; this we argue is an unpopular model in times of greater Government austerity. Here we evaluate a market-based mechanism for improving the performance of evaluativemore » and professional control mechanisms, the UK Institute of Environmental Management and Assessments' EIA Quality Mark. We do this by defining dimensions of effectiveness for the purposes of our evaluation, and by identifying international examples of the approaches taken to delivering the other control measures to validate the approach taken in the EIA Quality Mark. We then evaluate the EIA Quality Mark, when used in combination with legal procedures and an active judiciary, against the effectiveness dimensions and use time-series analysis of registrant data to examine its ability to progress practice. We conclude that the EIA Quality Mark has merit as a model for a market-based mechanism, and may prove a more financially palatable approach for delivering effective EIA in mature systems in countries that lack centralised agency oversight. It may, therefore, be of particular interest to some Member States of the European Union for ensuring forthcoming certification requirements stemming from recent amendments to the EIA Directive. - Highlights: • Quality control mechanisms in EIA are identified. • Effectiveness of EIA is conceptualised for evaluation purposes. • The UK IEMA EIA Quality Mark is introduced as a market-based mechanism. • The EIA Quality Mark is found to progress quality in many, but not all, areas.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malkoske, Kyle; Nielsen, Michelle; Brown, Erika
The Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) have worked together in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment and technologies, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. Early community engagement and uptake survey data showed 70% of Canadian centers are part of this process and that the data in the guideline documents reflect, and are influencing the way Canadian radiation treatmentmore » centres run their technical quality control programs. As the TQC development framework matured as a cross-country initiative, guidance documents have been developed in many clinical technologies. Recently, there have been new TQC documents initiated for Gamma Knife and Cyberknife technologies where the entire communities within Canada are involved in the review process. At the same time, QARSAC reviewed the suite as a whole for the first time and it was found that some tests and tolerances overlapped across multiple documents as single tests could pertain to multiple quality control areas. The work to streamline the entire suite has allowed for improved usability of the suite while keeping the integrity of single quality control areas. The suite will be published by the JACMP, in the coming year.« less
21 CFR 820.86 - Acceptance status.
Code of Federal Regulations, 2010 CFR
2010-04-01
... QUALITY SYSTEM REGULATION Acceptance Activities § 820.86 Acceptance status. Each manufacturer shall... product which has passed the required acceptance activities is distributed, used, or installed. ...
1985-09-01
service quality in the civilian sector. It was determined that acceptability by the patients eating in their rooms and by patients and personnel...performance significantly higher than the military food operation. CONCLUSION The results of the acceptability surveys of food and food service quality under
Whittingham, Koa; Sheffield, Jeanie; Boyd, Roslyn N
2016-10-19
Cerebral palsy (CP) impacts on the entire family in a manner that is long-term, complex and multifactorial. In addition, the quality of the parent-child relationship impacts on many and varied child outcomes, making the provision of easily accessible and evidence-based support to parents of children with CP a priority. This paper reports the protocol of a randomised controlled trial of an innovative and translatable online intervention, parenting acceptance and commitment therapy (PACT), for families of children with CP. We predict that participating in the PACT programme will be associated with improvements in the parent-child relationship, in child functioning and in adjustment and quality of life for both parent and child. We aim to recruit 66 parents of children (2-10 years old) diagnosed with CP to this study. Families will be randomly assigned to two groups: wait-list control and PACT. PACT is a parenting intervention grounded in acceptance and commitment therapy (ACT) and developed into an online course 'PARENT101 Parenting with Purpose' using the edX platform. All participants will be offered PACT before completion of the study. Assessments will take place at baseline, following completion of PACT and at 6-month follow-up (retention) and will focus on the parent-child relationship, parent and child adjustment and parent and child quality of life. Analysis will follow standard methods for randomised controlled trials using general linear models, specifically analysis of variance or analysis of covariance. Ethics approvals have been obtained through the Children's Health Queensland Hospital and Health Service Human Research Ethics Committee (HREC/15/QRCH/115) and The University of Queensland (2015001743). If efficacy is demonstrated, then the PARENT101 course has the potential to be disseminated widely in an accessible manner and at minimal cost. Further, the PACT framework may provide a blueprint for similar online courses with parents in a full range of contexts. ACTRN12616000351415; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Effect of peach gum polysaccharides on quality changes of white shrimp.
Yao, Xing-Cun; Chang, Cheng-Fei; Wu, Sheng-Jun
2015-01-01
Peach gum polysaccharides (PGPs) have both antibacterial and antioxidant activities. In this study, the retardation effect of the PGPs on the quality changes of white shrimp (Penaeus vannamei) during refrigerated storage was investigated. Shrimp samples were untreated with different concentrations of the PGPs solution and then they were stored under refrigerated conditions for 10 days. During refrigerated storage, shrimp samples were taken periodically and their total viable count, pH value, total volatile basic nitrogen, and overall acceptability score were evaluated. Compared to the control, treatment of the PGPs solution effectively retarded bacterial growth and pH changes, reduced total volatile basic nitrogen, and increased overall acceptability score of white shrimp (P. vannamei) during refrigerated storage. The results indicate that treatment of PGPs could be a promising means to preserve white shrimp (P. vannamei). Copyright © 2014 Elsevier B.V. All rights reserved.
Dillman Carpentier, Francesca R; Parrott, M Scott; Northup, C Temple
2014-01-01
Three experimental studies (N = 286) tested how priming the concepts of sex or romance influence the way people perceive other social media users. Participants first completed a word-search task containing sexual (intercourse, lust), romantic (love, heart), or control words. Participants then evaluated a target's sexual qualities and romantic qualities based on social media profiles, as well as rated their acceptance of the priming stimuli. Results suggested that sex primes led participants to judge targets as being more alluring, racy, and provocative, whereas romance primes led participants to judge targets as being more tender, sentimental, and kind. Both men and women found all primes to be equally acceptable content; women were not averse to these mainstream, non-explicit sexual stimuli. Findings are discussed in terms of viewing sex and romance as distinct, yet related networks of concepts and the need to disentangle sex, romance, and sexualized views of romance.
Choi, Yun-Sang; Kim, Hyun-Wook; Kim, Young-Boong; Kim, Cheon-Jei
2015-01-01
The combined effects of smoking and boiling on the proximate composition, technological quality traits, shear force, and sensory characteristics of the Korean traditional boiled loin were studied. Cooking loss, processing loss, and shear force were lower in the smoked/boiled samples than those in the control (without smoking treatment) (p<0.05). The results showed that the boiled loin samples between the control and treatment did not differ significantly in protein, fat, or ash contents, or pH values (p>0.05). The treated samples had higher score for overall acceptability than the control (p<0.05). Thus, these results show that the Korean traditional boiled loin treated with smoking for 60 min before boiling had improved physicochemical properties and sensory characteristics. PMID:26761822
Jin, Sang Keun; Choi, Jung Seok; Lee, Seung Jae; Lee, Seung Yun; Hur, Sun Jin
2016-10-31
The effects of thyme and rosemary on the quality characteristics of sausages during cold storage were investigated. Sausages were prepared with thyme and rosemary powder (1 and 2%) and stored for 6 weeks at 10℃. The pH was significantly decreased in sausages by addition of thyme and rosemary compared to that observed in the control before and after storage. At 4 weeks of storage, the residual nitrite content was decreased by thyme and rosemary compared to the control. Lightness (L*) and yellowness (b*) were increased during storage, whereas redness (a*) and whiteness (W) were decreased before and after storage by addition of thyme and rosemary. The amount of TPC and lactic acid bacteria was lower at the end of storage in sausage containing thyme and rosemary. The 2, 2-diphenyl-1-picryl-hydrazyl-hydrate (DPPH) radical scavenging capacity of sausages was increased by addition of thyme and rosemary compared to that in the control before and after storage. In particular, T2 (0.2% thyme addition) showed the highest DPPH radical scavenging capacity during storage. In a sensory evaluation, flavor and overall acceptability were lower in sausages containing thyme and rosemary than in the control. However, at the end of storage (6 wk), aroma, flavor and overall acceptability were not significantly different among the sausage samples.
Jin, Sang Keun; Choi, Jung Seok; Lee, Seung Jae
2016-01-01
The effects of thyme and rosemary on the quality characteristics of sausages during cold storage were investigated. Sausages were prepared with thyme and rosemary powder (1 and 2%) and stored for 6 weeks at 10℃. The pH was significantly decreased in sausages by addition of thyme and rosemary compared to that observed in the control before and after storage. At 4 weeks of storage, the residual nitrite content was decreased by thyme and rosemary compared to the control. Lightness (L*) and yellowness (b*) were increased during storage, whereas redness (a*) and whiteness (W) were decreased before and after storage by addition of thyme and rosemary. The amount of TPC and lactic acid bacteria was lower at the end of storage in sausage containing thyme and rosemary. The 2, 2-diphenyl-1-picryl-hydrazyl-hydrate (DPPH) radical scavenging capacity of sausages was increased by addition of thyme and rosemary compared to that in the control before and after storage. In particular, T2 (0.2% thyme addition) showed the highest DPPH radical scavenging capacity during storage. In a sensory evaluation, flavor and overall acceptability were lower in sausages containing thyme and rosemary than in the control. However, at the end of storage (6 wk), aroma, flavor and overall acceptability were not significantly different among the sausage samples. PMID:27857542
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-04
... instructions for submitting comments. B. Email: cox[email protected] . C. Mail: EPA-R03-OAR-2012-0619, Kathleen Cox, Associate Director, Office of Permits and Air Toxics, Mailcode 3AP10, U.S. Environmental... previously-listed EPA Region III address. Such deliveries are only accepted during the Docket's normal hours...
The Relationship between the Training Function and ISO-9000 Registration.
ERIC Educational Resources Information Center
Maxwell, Randy C.; Jost, Karen L.
ISO 9000 is one of a series of international standards providing guidelines and governing quality of products and services. The ISO 9000 certification demonstrates the capability of a supplier to control the processes that determine the acceptability of the product or service being supplied. This paper focuses on the training aspects of ISO 9000…
Statistical process control methods allow the analysis and improvement of anesthesia care.
Fasting, Sigurd; Gisvold, Sven E
2003-10-01
Quality aspects of the anesthetic process are reflected in the rate of intraoperative adverse events. The purpose of this report is to illustrate how the quality of the anesthesia process can be analyzed using statistical process control methods, and exemplify how this analysis can be used for quality improvement. We prospectively recorded anesthesia-related data from all anesthetics for five years. The data included intraoperative adverse events, which were graded into four levels, according to severity. We selected four adverse events, representing important quality and safety aspects, for statistical process control analysis. These were: inadequate regional anesthesia, difficult emergence from general anesthesia, intubation difficulties and drug errors. We analyzed the underlying process using 'p-charts' for statistical process control. In 65,170 anesthetics we recorded adverse events in 18.3%; mostly of lesser severity. Control charts were used to define statistically the predictable normal variation in problem rate, and then used as a basis for analysis of the selected problems with the following results: Inadequate plexus anesthesia: stable process, but unacceptably high failure rate; Difficult emergence: unstable process, because of quality improvement efforts; Intubation difficulties: stable process, rate acceptable; Medication errors: methodology not suited because of low rate of errors. By applying statistical process control methods to the analysis of adverse events, we have exemplified how this allows us to determine if a process is stable, whether an intervention is required, and if quality improvement efforts have the desired effect.
Zhilinskaya, Nataliya V; Sarkisyan, Varuzhan A; Vorobieva, Valentina M; Vorobieva, Irina S; Kochetkova, Alla A; Smirnova, Elena A; Glazkova, Irina V
2018-01-01
Type 2 diabetes is one of the most common noncommunicable diseases worldwide. The quality of life of people with this metabolic disorder is highly related to nutrition, given that products for glycemic control are of great importance for them. In this study, we have developed marmalades for glycemic control with the aims to investigate the most important sensory characteristics, to study the impact of the sensory properties on the acceptability of these marmalades, and to evaluate a difference in the acceptability of the marmalade samples between healthy people and people with type 2 diabetes. The main objects of the investigation were agar-, gelatin-, and pectin-based marmalades with maltitol, dried fruits, and berries for glycemic control. By means of descriptive sensory analysis, we have shown that major factors of the sensory differentiation of marmalade samples are the type of gelling agent and presence of nonsoluble components such as apple puree, which influencing the perception of "off-flavor," "gumminess," and "springiness" sensory attributes. Results of this research show that even with significant differences in sensory attributes it is possible to develop marmalade for glycemic control that will have no differences in the total liking score for the perception of both healthy people and patients with type 2 diabetes.
Process Improvements in Training Device Acceptance Testing: A Study in Total Quality Management
1990-12-12
Quality Management , a small group of Government and industry specialists examined the existing training device acceptance test process for potential improvements. The agreed-to mission of the Air Force/Industry partnership was to continuously identify and promote implementable approaches to minimize the cost and time required for acceptance testing while ensuring that validated performance supports the user training requirements. Application of a Total Quality process improvement model focused on the customers and their requirements, analyzed how work was accomplished, and
Effect of dietary fibers on physico-chemical, sensory and textural properties of Misti Dahi.
Raju, P Narender; Pal, Dharam
2014-11-01
Misti dahi, a popular ethnic delicacy of eastern India analogous to caramel coloured set style sweetened yoghurt, besides several therapeutic virtues, contains high fat and sugar. Alike people elsewhere in the world, people in India too are now becoming health conscious and are aware of the relation between diet and health. Hence, high fat and sugar contents are causes of concern for the successful marketing of misti dahi in India. With a view to enhance the health attributes of misti dahi and improve marketability, three commercial dietary fiber preparations (inulin, soy fiber and oat fiber) were incorporated and their effect on the product's quality in terms of physicochemical, sensory and textural quality was assessed. Standard method was followed for the preparation of fiber fortified misti dahi (FFMD). Among the three dietary fibers, inulin significantly decreased viscosity and instrumental firmness and increased lightness (L*), redness (a*), yellowness (b*), syneresis and work of shear values of FFMD. Oat fiber settled at the bottom and gave a poor appearance. Soy fiber did not affect the flavor of FFMD. Although overall acceptability scores of inulin and soy fiber containing FFMD were significantly lower than control, they were still above the minimum acceptable score. Based on the results obtained in the present study, it was concluded that acceptable quality FFMD could be prepared using inulin and soy fiber at 1.5 % level of fortification.
Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories
Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N’Faly; Martel, Lise D.; Dahourou, Anicet George
2017-01-01
Background Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Methods and findings Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. Conclusions The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation. PMID:29190713
Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.
VanSteelandt, Amanda; Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N'Faly; Martel, Lise D; Dahourou, Anicet George
2017-01-01
Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.
A Review of International Space Station Habitable Element Equipment Offgassing Characteristics
NASA Technical Reports Server (NTRS)
Perry, Jay L.
2010-01-01
Crewed spacecraft trace contaminant control employs both passive and active methods to achieve acceptable cabin atmospheric quality. Passive methods include carefully selecting materials of construction, employing clean manufacturing practices, and minimizing systems and payload operational impacts to the cabin environment. Materials selection and manufacturing processes constitute the first level of equipment offgassing control. An element-level equipment offgassing test provides preflight verification that passive controls have been successful. Offgassing test results from multiple International Space Station (ISS) habitable elements and cargo vehicles are summarized and implications for active contamination control equipment design are discussed
Effects of mindfulness meditation on chronic pain: a randomized controlled trial.
la Cour, Peter; Petersen, Marian
2015-04-01
This randomized controlled clinical trial investigated the effects of mindfulness meditation on chronic pain. A total of 109 patients with nonspecific chronic pain were randomized to either a standardized mindfulness meditation program (mindfulness-based stress reduction [MBSR]) or to a wait list control. Pain, physical function, mental function, pain acceptance, and health-related quality of life were measured. The SF36 vitality scale was chosen as the primary outcome measure; the primary end point was after completing the MBSR course. Within a 2.5-year period, 43 of the 109 randomized patients completed the mindfulness program, while 47 remained in the control group. Data were compared at three time points: at baseline, after completion of the course/waiting period, and at the 6-month follow-up. Significant effect (Cohen's d = 0.39) was found on the primary outcome measure, the SF36 vitality scale. On the secondary variables, significant medium to large size effects (Cohen's d = 0.37-0.71) were found for lower general anxiety and depression, better mental quality of life (psychological well-being), feeling in control of the pain, and higher pain acceptance. Small (nonsignificant) effect sizes were found for pain measures. There were no significant differences in the measures just after the intervention vs the 6-month follow-up. A standardized mindfulness program (MBSR) contributes positively to pain management and can exert clinically relevant effects on several important dimensions in patients with long-lasting chronic pain. © 2014 American Academy of Pain Medicine.
21 CFR 161.173 - Canned wet pack shrimp in transparent or nontransparent containers.
Code of Federal Regulations, 2010 CFR
2010-04-01
... (dorsal tract, back vein, or sand vein). (ii) Deveined shrimp containing not less than 95 percent by...) Acceptable quality level (AQL). The maximum percent of defective sample units permitted in a lot that will be accepted approximately 95 percent of the time. (ii) Sampling plans: Acceptable Quality Level 6.5 Lot size...
Wang, Xijun; Lv, Haitao; Sun, Hui; Jiang, Xingang; Wu, Zeming; Sun, Wenjun; Wang, Ping; Liu, Lian; Bi, Kaishun
2008-01-01
A completely validated method based on HPLC coupled with photodiode array detector (HPLC-UV) was described for evaluating and controlling quality of Yin Chen Hao Tang extract (YCHTE). First, HPLC-UV fingerprint chromatogram of YCHTE was established for preliminarily elucidating amount and chromatographic trajectory of chemical constituents in YCHTE. Second, for the first time, five mainly bioactive constituents in YCHTE were simultaneously determined based on fingerprint chromatogram for furthermore controlling the quality of YCHTE quantitatively. The developed method was applied to analyze 12 batches of YCHTE samples which consisted of herbal drugs from different places of production, showed acceptable linearity, intraday (RSD <5%), interday precision (RSD <4.80%), and accuracy (RSD <2.80%). As a result, fingerprint chromatogram determined 15 representative general fingerprint peaks, and the fingerprint chromatogram resemblances are all better than 0.9996. The contents of five analytes in different batches of YCHTE samples do not indicate significant difference. So, it is concluded that the developed HPLC-UV method is a more fully validated and complete method for evaluating and controlling the quality of YCHTE.
Quality Assurance in Ontario's Postsecondary Education Sector
ERIC Educational Resources Information Center
Klassen, Tim
2012-01-01
It is generally accepted that Canadian postsecondary education enjoys an international reputation for quality. However, Canada does not have an accepted, national framework to understand, measure, or clearly define the actual quality of the postsecondary education sector. In this, Canada is seen as unique when compared with other developed…
Effects of alternative silvicultural methods on scenic and recreational quality
Mark Brunson; Bo Shelby
1992-01-01
Timber stands harvested using different silvicultural regimes were evaluated for acceptability as places for hiking, camping, and scenic viewing. "New Forestry" stands were more acceptable than stands managed using traditional practices. Stands were rated differently for different uses, with camping quality judged lower than hiking or scenic quality.
Richards, Suzanne H; Coast, Joanna; Gunnell, David J; Peters, Tim J; Pounsford, John; Darlow, Mary-Anne
1998-01-01
Objective: To compare effectiveness and acceptability of early discharge to a hospital at home scheme with that of routine discharge from acute hospital. Design: Pragmatic randomised controlled trial. Setting: Acute hospital wards and community in north of Bristol, with a catchment population of about 224 000 people. Subjects: 241 hospitalised but medically stable elderly patients who fulfilled criteria for early discharge to hospital at home scheme and who consented to participate. Interventions: Patients’ received hospital at home care or routine hospital care. Main outcome measures: Patients’ quality of life, satisfaction, and physical functioning assessed at 4 weeks and 3 months after randomisation to treatment; length of stay in hospital and in hospital at home scheme after randomisation; mortality at 3 months. Results: There were no significant differences in patient mortality, quality of life, and physical functioning between the two arms of the trial at 4 weeks or 3 months. Only one of 11 measures of patient satisfaction was significantly different: hospital at home patients perceived higher levels of involvement in decisions. Length of stay for those receiving routine hospital care was 62% (95% confidence interval 51% to 75%) of length of stay in hospital at home scheme. Conclusions: The early discharge hospital at home scheme was similar to routine hospital discharge in terms of effectiveness and acceptability. Increased length of stay associated with the scheme must be interpreted with caution because of different organisational characteristics of the services. Key messages Pressure on hospital beds, the increasing age of the population, and high costs associated with acute hospital care have fuelled the search for alternatives to inpatient hospital care There were no significant differences between early discharge to hospital at home scheme and routine hospital care in terms of patient quality of life, physical functioning, and most measures of patient satisfaction Length of stay for hospital patients was significantly shorter than that of hospital at home patients, but, owing to qualitative differences between the two interventions, this does not necessarily mean differences in effectiveness Early discharge to hospital at home provides an acceptable alternative to routine hospital care in terms of effectiveness and patient acceptability PMID:9624070
Gudbergsson, Sævar Berg; Dahl, Alv A; Loge, Jon Håvard; Thorsen, Lene; Oldervoll, Line M; Grov, Ellen K
2015-02-01
This focused review examines randomized controlled studies included by the term "cancer rehabilitation" in PubMed. The research questions concern the type of interventions performed and their methodological quality. Using the Medical Subject Headings (MeSH) terms: neoplasm AND rehabilitation, all articles with randomized controlled studies that included adult cancer patients, written in English, were extracted from PubMed. Papers covering physical exercise, psychiatric/psychological treatment or social support only were excluded as they had been reviewed recently. Abstracts and papers were assessed by 3 pairs of reviewers, and descriptive information was extracted systematically. Methodological quality was rated on a 10-item index scale, and the cut-off for acceptable quality was set at ≥ 8. A total of 132 (19%) of the 683 identified papers met the eligibility criteria and were assessed in detail. The papers were grouped into 5 thematic categories: 44 physical; 15 art and expressive; 47 psycho-educative; 21 emotionally supportive; and 5 others. Good quality of design was observed in 32 studies, 18 of them uni-dimensional and 14 multi-dimensional. Published randomized controlled studies on cancer rehabilitation are heterogeneous in terms of content and samples, and are mostly characterized by suboptimal design quality. Future studies should be more specific and well-designed with sufficient statistical strength.
Quality of Life for Diverse Older Adults in Assisted Living: The Centrality of Control.
Koehn, Sharon D; Mahmood, Atiya N; Stott-Eveneshen, Sarah
This pilot project asked: How do ethnically diverse older adult residents of assisted living (AL) facilities in British Columbia (BC) experience quality of life? And, what role, if any, do organizational and physical environmental features play in influencing how quality of life is experienced? The study was conducted at three AL sites in BC: two ethnoculturally targeted and one nontargeted. Environmental audits at each site captured descriptive data on policies, fees, rules, staffing, meals, and activities, and the built environment of the AL building and neighborhood. Using a framework that understands the quality of life of older adults to be contingent on their capability to pursue 5 conceptual attributes-attachment, role, enjoyment, security, and control-we conducted 3 focus groups with residents (1 per site) and 6 interviews with staff (2 per site). Attributes were linked to the environmental features captured in the audits. All dimensions of the environment, especially organizational, influence tenants' capability to attain the attributes of quality of life, most importantly control. Although many tenants accept the trade-off between increased safety and diminished control that accompanies a move into AL, more could be done to minimize that loss. Social workers can advocate for the necessary multi-sectoral changes.
Averina, Maria; Jakobsen, Raymond
2017-05-01
Background Measurements of ionized calcium (Ca 2+ ) at concentrations less than 0.3 mmol/L are required for postfilter control in patients who receive extracorporeal circulation with sodium citrate anticoagulation. This study evaluates the stability of the Ca 2+ measurements at such concentrations. Methods The stability of the Ca 2+ measurements was tested by measuring daily the external standard Qualicheck concentration 3 s7950, Radiometer (0.22-0.25 mmol/L) by blood gas instruments ABL800 and ABL90, Radiometer. Two different Ca 2+ membrane lots were tested for the usual membrane lifetime of 12 weeks at ABL800 instruments. For the ABL90 instrument, the sensor cassette (with Ca 2+ membrane and electrode) was replaced after four weeks as required. Results We observed over 40% Ca 2+ increase within the usual 12 weeks lifetime of the Ca 2+ membrane at the ABL800 instruments. Measurements of Ca 2+ at concentrations less than 0.3 mmol/L were within acceptable limits for both ABL800 and ABL90 instruments when Ca 2+ membrane and sensor cassette were replaced after four weeks. Conclusions For ABL800 instruments, it is necessary to use an extra quality control (<0.3 mmol/L) in addition to the usual quality controls to monitor Ca 2+ measurements below 0.3 mmol/L. The acceptable stability of the Ca 2+ measurements can be achieved by the Ca 2+ membrane and sensor cassette replacement after four weeks. If the usual 12 weeks of Ca 2+ membrane lifetime is maintained, it may result in a clinically significant overestimation of Ca 2+ by ABL800 instruments.
2012-01-01
Background Health status is one of the basic factors of a high quality of life and the problem of the acceptance of illness is important for adaptation to the limitations imposed by it. The purpose of the study was the evaluation of the quality of life, satisfaction with life and the acceptance of illness by malaria patients, as well as the discovery of a relationship between studied parameters. Methods The study was undertaken in August 2010, on 120 Nigerian patients with confirmed malaria. A method of diagnostic survey, based on standardized scales - Acceptance of Illness Scale, The Satisfaction With Life Scale and a standardized survey questionnaire World Health Organization Quality of Life/BREF - was used in this study. Descriptive statistics, variability range, 95% confidence interval, correlation analysis, Spearman’s non-parametric correlation coefficient, Mann–Whitney test and Kruskal-Wallis test were applied and the, so called, test statistics was calculated, followed by the calculation of the test probability p. Results of analyses were presented in a box graph, and a graph of dispersion. Results A dominating share in the adjective scale of the AIS scale was the category of “no acceptance”, given by 71.7% of respondents. The average level of a “somatic domain” was 41.7, and of a “social domain” was 62.8. The mean satisfaction of life evaluation in the SWLS scale was 18 points. The correlation between acceptance of the disease and quality of life for the psychological domain was 0.39***, and between acceptance of the disease and satisfaction with life was 0.40***. The correlation between satisfaction with life and quality of life for the psychological domain was 0.65***, and between satisfaction with life and quality of life for the environment domain was 0.60***. The mean level of AIS for the studied population of men was 16.5, and test probability: p = 0.0014**, and for the environment domain the level was 50, and the test probability: p = 0.0073**. For quality of life in the social sphere the test probability: p = 0.0013** in relatively older individuals. Conclusion The majority of people do not accept their condition. Evaluation of the quality of life was the highest in the social domain, and the lowest in the somatic domain. There is a statistically significant correlation between the level of acceptance of illness and the quality of life and satisfaction with life. The strongest correlation is found between satisfaction with life and the evaluation of the quality of life in psychological and environmental domains. Men evaluate their quality of life in the environmental domain higher and demonstrate a higher acceptance of their disease. There is a correlation regarding a significantly higher quality of life in the social sphere in relatively older people. PMID:22616635
Adaptive quantization-parameter clip scheme for smooth quality in H.264/AVC.
Hu, Sudeng; Wang, Hanli; Kwong, Sam
2012-04-01
In this paper, we investigate the issues over the smooth quality and the smooth bit rate during rate control (RC) in H.264/AVC. An adaptive quantization-parameter (Q(p)) clip scheme is proposed to optimize the quality smoothness while keeping the bit-rate fluctuation at an acceptable level. First, the frame complexity variation is studied by defining a complexity ratio between two nearby frames. Second, the range of the generated bits is analyzed to prevent the encoder buffer from overflow and underflow. Third, based on the safe range of the generated bits, an optimal Q(p) clip range is developed to reduce the quality fluctuation. Experimental results demonstrate that the proposed Q(p) clip scheme can achieve excellent performance in quality smoothness and buffer regulation.
Martinez, Cristina S; Ribotta, Pablo D; Añón, María Cristina; León, Alberto E
2014-03-01
The technological and sensory quality of pasta made from bread wheat flour substituted with wholemeal amaranth flour (Amaranthus mantegazzianus) at four levels, 15, 30, 40 and 50% w/w was investigated. The quality of the resulted pasta was compared to that of control pasta made from bread wheat flour. The flours were analyzed for chemical composition and pasting properties. Cooking behavior, color, raw and cooked pasta texture, scanning electron microscopy and sensory evaluation were determined on samples. The pasta obtained from amaranth flour showed some detriment of the technological and sensory quality. So, a maximum substitution level of 30% w/w was defined. This is an equilibrium point between an acceptable pasta quality and the improved nutritional and functional properties from the incorporation of amaranth flour.
Schermer, Tjard R; Akkermans, Reinier P; Crockett, Alan J; van Montfort, Marian; Grootens-Stekelenburg, Joke; Stout, Jim W; Pieters, Willem
2011-01-01
Spirometry has become an indispensable tool in primary care to exclude, diagnose, and monitor chronic respiratory conditions, but the quality of spirometry tests in family practices is a reason for concern. Aim of this study was to investigate whether a combination of e-learning and bimonthly performance feedback would improve spirometry test quality in family practices in the course of 1 year. Our study was a cluster trial with 19 family practices allocated to intervention or control conditions through minimization. Intervention consisted of e-learning and bimonthly feedback reports to practice nurses. Control practices received only the joint baseline workshop. Spirometry quality was assessed by independent lung function technicians. Two outcomes were defined, with the difference between rates of tests with 2 acceptable and repeatable blows being the primary outcome and the difference between rates of tests with 2 acceptable blows being the secondary outcome. We used multilevel logistic regression analysis to calculate odds ratios (ORs) for an adequate test in intervention group practices. We analyzed 1,135 tests. Rate of adequate tests was 33% in intervention and 30% in control group practices (OR = 1.3; P=.605). Adequacy of tests did not differ between groups but tended to increase with time: OR = 2.2 (P = .057) after 3 and OR = 2.0 (P = .086) in intervention group practices after 4 feedback reports. When ignoring test repeatability, these differences between the groups were slightly more pronounced: OR = 2.4 (P = .033) after 3 and OR=2.2 (P = .051) after 4 feedback reports. In the course of 1 year, we observed a small and late effect of e-learning and repeated feedback on the quality of spirometry as performed by family practice nurses. This intervention does not seem to compensate the lack of rigorous training and experience in performing spirometry tests in most practices.
Mira, Nieves Orta; Serrano, María del Remedio Guna; Martínez, José Carlos Latorre; Ovies, María Rosario; Pérez, José L; Cardona, Concepción Gimeno
2010-01-01
Human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarized the results obtained from the 2008 SEIMC External Quality Control Program for HIV-1 and HCV viral loads. In the HIV-1 program, a total of five standards were sent. One standard consisted in seronegative human plasma, while the remaining four contained plasma from 3 different viremic patients, in the range of 2-5 log(10) copies/mL; two of these standards were identical aiming to determine repeatability. The specificity was complete for all commercial methods, and no false positive results were reported by the participants. A significant proportion of the laboratories (24% on average) obtained values out of the accepted range (mean +/- 0.2 log(10) copies/mL), depending on the standard and on the method used for quantification. Repeatability was very good, with up to 95% of laboratories reporting results within the limits (D < 0.5 log(10) copias/mL). The HCV program consisted of two standards with different viral load contents. Most of the participants (88,7%) obtained results within the accepted range (mean +/- 1.96 SD log(10) UI/mL). Post-analytical errors due to mistranscription of the results were detected for HCV, but not for the HIV-1 program. Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up. 2010 Elsevier España S.L. All rights reserved.
Orta Mira, Nieves; Del Remedio Guna Serrano, María; Latorre Martínez, José-Carlos; Medina González, Rafael; Rosario Ovies, María; Poveda, Marta; Ruiz de Gopegui, Enrique; Gimeno Cardona, Concepción
2015-07-01
Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarized the results obtained from the 2013 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of five standards were sent. One standard consisted in seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (25% on average) obtained values out of the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 98.9% of laboratories reporting results within the limits (D < 0.5 log10 copies/mL). The HBV and HCV program consisted of two standards with different viral load contents. Most of the participants, 82% in the case of HCV and 78% in the HBV, obtained all the results within the accepted range (mean ± 1.96 SD log10 UI/mL). Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.
Medina González, Rafael; Orta Mira, Nieves; Guna Serrano, María Del Remedio; Latorre Martínez, José-Carlos; Gopegui, Enrique Ruiz de; Rosario Ovies, María; Poveda, Marta; Gimeno Cardona, Concepción
2016-07-01
Human immunodeficiency virus type 1 (HIV-1), hepatitis B virus (HBV) and hepatitis C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarizes the results obtained from the 2014 SEIMC (Spanish Society of Infectious Diseases and Clinical Microbiology) External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of 5 standards were sent. One standard consisted in seronegative human plasma, while the remaining 4 contained plasma from 3 different viremic patients, in the range of 2-5 log10 copies/mL; 2 of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (30.8% on average) obtained values out of the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 95.8% of laboratories reporting results within the limits (Δ < 0.5 log10 copies/mL). The HBV and HCV program consisted of 2 standards with different viral load contents. Most of the participants, 83.7% in the case of HCV and 87.9% in the HBV, obtained all the results within the accepted range (mean ± 1.96 standard deviations log10 IU/mL). Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Maskell, Jessica; Newcombe, Peter; Martin, Graham; Kimble, Roy
2014-02-01
Burns leave patients with long-term physical scarring. Children with scarring are required to face challenges of reintegration into their community, including acceptance of an altered appearance and acceptance by others. This can be difficult given society's preoccupation with physical appearance. Limited research exists investigating validity of cosmetic camouflage as a psychosocial intervention for children with scarring. This study investigated whether using cosmetic camouflage (Microskin™) had a positive impact on health-related quality of life, self-concept and psychopathology for children and adolescents (8-17 years) with burn scarring. A prospective multi-centre randomised controlled trial was conducted across Australian and New Zealand paediatric hospitals. 63 participants (49 females, mean age 12.7 ± 2.1 years) were enrolled. Data points were baseline (Time 1) and at 8 weeks (Time 2) using reliable and valid psychometric measures. Findings indicate there were significant improvements in socialisation, school and appearance scales on the Paediatric Quality of Life Inventory and psychopathology scores particularly peer problems decreased. However self-concept remained stable from baseline throughout intervention use. Cosmetic camouflage appears to have a positive impact on quality of life particularly socialisation. Cosmetic camouflage is a valid tool to assist children with scarring to actively participate socially within their communities. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Sellamuthu, Periyar Selvam; Mafune, Mpho; Sivakumar, Dharini; Soundy, Puffy
2013-09-01
Postharvest application of prochloraz fungicide is commercially practiced to control anthracnose, a postharvest disease in avocado. Increasing consumer concern regarding food safety and demand for organically produced fruits make it necessary to search for natural environmentally friendly alternative products and processes for the fruit industry. A combination of modified atmosphere packaging (MAP; ∼8% CO₂, 2% O₂) plus thyme oil (TO) was evaluated on the incidence and severity of anthracnose, physiological disorders (grey pulp, vascular browning), fruit quality parameters (L*, h°, firmness, weight loss) and sensory parameters (taste, texture, flavour and overall acceptance), phenylalanine ammonia-lyase (PAL) enzyme activity, total phenolic compounds, flavonoid contents and antioxidant activity in avocados ('Fuerte' and 'Hass' cultivars) held at 10 °C cold storage for 18 days and thereafter, ripened at 25 °C for 5-10 days. Stand-alone MAP, commercial treatment (prochloraz 0.05%) and untreated (control) fruit were included for comparison. MAP + TO treatment significantly (P < 0.05) reduced the incidence and severity of anthracnose, grey pulp, vascular browning, weight loss and loss of fruit firmness, and showed acceptable taste, flavour, texture and higher overall acceptance, increased PAL activity, total phenolic compounds, flavonoid contents and antioxidant activity, after ripening at 25 °C followed by cold storage at 10 °C. This investigation recommends MAP + TO combination treatment as a suitable alternative to the currently adopted prochloraz application. © 2013 Society of Chemical Industry.
Illness identity in young adults with refractory epilepsy.
Luyckx, Koen; Oris, Leen; Raymaekers, Koen; Rassart, Jessica; Moons, Philip; Verdyck, Ludo; Mijnster, Teus; Mark, Ruth E
2018-03-01
Refractory epilepsy is an intrusive condition with important implications for daily functioning in emerging and young adulthood. The present study examined the degree to which refractory epilepsy is integrated in one's identity, and examined how such a sense of illness identity was related to health-related quality of life (HRQOL). A total of 121 18- to 40-year-old patients with refractory epilepsy (56.2% women) completed self-report questionnaires assessing the four illness identity states of acceptance, enrichment, engulfment, and rejection (Illness Identity Questionnaire (IIQ)); HRQOL (Quality of Life in Epilepsy Inventory - 31); and seizure frequency and severity (Liverpool Seizure Severity Scale (LSSS)). Illness identity scores were compared with a sample of 191 patients with a nonneurological chronic disease (congenital heart disease). Hierarchical regression analyses were conducted to assess the predictive value of illness identity for HRQOL when simultaneously controlling for demographic and clinical features. Patients with refractory epilepsy scored higher on rejection and engulfment and lower on acceptance when compared with patients with congenital heart disease. Further, seizure severity and number of medication side-effects were positively related to engulfment and negatively to acceptance. Finally, when simultaneously controlling for various demographic and clinical variables, illness identity significantly predicted HRQOL (with engulfment being the strongest and most consistent predictor). The extent to which patients with refractory epilepsy succeed in integrating their illness into their identity may have important implications for HRQOL. Clinicians should be especially attentive for signs that patients feel engulfed by their epilepsy. Copyright © 2018 Elsevier Inc. All rights reserved.
Scanning technology selection impacts acceptability and usefulness of image-rich content*†
Alpi, Kristine M.; Brown, James C.; Neel, Jennifer A.; Grindem, Carol B.; Linder, Keith E.; Harper, James B.
2016-01-01
Objective Clinical and research usefulness of articles can depend on image quality. This study addressed whether scans of figures in black and white (B&W), grayscale, or color, or portable document format (PDF) to tagged image file format (TIFF) conversions as provided by interlibrary loan or document delivery were viewed as acceptable or useful by radiologists or pathologists. Methods Residency coordinators selected eighteen figures from studies from radiology, clinical pathology, and anatomic pathology journals. With original PDF controls, each figure was prepared in three or four experimental conditions: PDF conversion to TIFF, and scans from print in B&W, grayscale, and color. Twelve independent observers indicated whether they could identify the features and whether the image quality was acceptable. They also ranked all the experimental conditions of each figure in terms of usefulness. Results Of 982 assessments of 87 anatomic pathology, 83 clinical pathology, and 77 radiology images, 471 (48%) were unidentifiable. Unidentifiability of originals (4%) and conversions (10%) was low. For scans, unidentifiability ranged from 53% for color, to 74% for grayscale, to 97% for B&W. Of 987 responses about acceptability (n=405), 41% were said to be unacceptable, 97% of B&W, 66% of grayscale, 41% of color, and 1% of conversions. Hypothesized order (original, conversion, color, grayscale, B&W) matched 67% of rankings (n=215). Conclusions PDF to TIFF conversion provided acceptable content. Color images are rarely useful in grayscale (12%) or B&W (less than 1%). Acceptability of grayscale scans of noncolor originals was 52%. Digital originals are needed for most images. Print images in color or grayscale should be scanned using those modalities. PMID:26807048
48 CFR 46.502 - Responsibility for acceptance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Responsibility for acceptance. 46.502 Section 46.502 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Acceptance 46.502 Responsibility for acceptance. Acceptance of...
Wood, Tim J; Moore, Craig S; Horsfield, Carl J; Saunderson, John R; Beavis, Andrew W
2015-01-01
The purpose of this study was to develop size-based radiotherapy kilovoltage cone beam CT (CBCT) protocols for the pelvis. Image noise was measured in an elliptical phantom of varying size for a range of exposure factors. Based on a previously defined "small pelvis" reference patient and CBCT protocol, appropriate exposure factors for small, medium, large and extra-large patients were derived which approximate the image noise behaviour observed on a Philips CT scanner (Philips Medical Systems, Best, Netherlands) with automatic exposure control (AEC). Selection criteria, based on maximum tube current-time product per rotation selected during the radiotherapy treatment planning scan, were derived based on an audit of patient size. It has been demonstrated that 110 kVp yields acceptable image noise for reduced patient dose in pelvic CBCT scans of small, medium and large patients, when compared with manufacturer's default settings (125 kVp). Conversely, extra-large patients require increased exposure factors to give acceptable images. 57% of patients in the local population now receive much lower radiation doses, whereas 13% require higher doses (but now yield acceptable images). The implementation of size-based exposure protocols has significantly reduced radiation dose to the majority of patients with no negative impact on image quality. Increased doses are required on the largest patients to give adequate image quality. The development of size-based CBCT protocols that use the planning CT scan (with AEC) to determine which protocol is appropriate ensures adequate image quality whilst minimizing patient radiation dose.
Statistical process management: An essential element of quality improvement
NASA Astrophysics Data System (ADS)
Buckner, M. R.
Successful quality improvement requires a balanced program involving the three elements that control quality: organization, people and technology. The focus of the SPC/SPM User's Group is to advance the technology component of Total Quality by networking within the Group and by providing an outreach within Westinghouse to foster the appropriate use of statistic techniques to achieve Total Quality. SPM encompasses the disciplines by which a process is measured against its intrinsic design capability, in the face of measurement noise and other obscuring variability. SPM tools facilitate decisions about the process that generated the data. SPM deals typically with manufacturing processes, but with some flexibility of definition and technique it accommodates many administrative processes as well. The techniques of SPM are those of Statistical Process Control, Statistical Quality Control, Measurement Control, and Experimental Design. In addition, techniques such as job and task analysis, and concurrent engineering are important elements of systematic planning and analysis that are needed early in the design process to ensure success. The SPC/SPM User's Group is endeavoring to achieve its objectives by sharing successes that have occurred within the member's own Westinghouse department as well as within other US and foreign industry. In addition, failures are reviewed to establish lessons learned in order to improve future applications. In broader terms, the Group is interested in making SPM the accepted way of doing business within Westinghouse.
Profile of a cell test database and a corresponding reliability database
NASA Technical Reports Server (NTRS)
Brearley, George R.; Klein, Glenn C.
1992-01-01
The development of computerized control, and data retrieval for aerospace cell testing affords an excellent opportunity to incorporate three specific concepts to both manage the test area and to track product performance on a real-time basis. The adoption and incorporation of precepts fostered by this total quality management (TQM) initiative are critical to us for retaining control of our business while substantially reducing the separate quality control inspection activity. Test discrepancies are all 'equally bad' in cell acceptance testing because, for example, we presently do not discriminate between 1 or 25 mV for an overvoltage condition. We must take leadership in classifying such discrepancies in order to expedite their clearance and redirect our resources for prevention activities. The development and use of engineering alerts (or guardbanding) which more closely match our product capabilities and are toleranced tighter than the required customer specification are paramount to managing the test unit in order to remain both quality and cost effective.
JV Task 94 - Air Quality V: Mercury, Trace Elements, SO3, and Particulate Matter Conference
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas A. Erickson
2007-01-31
This final report summarizes the planning, preparation, facilitation and production, and summary of the conference entitled 'Air Quality V: Mercury, Trace Elements, SO{sub 3}, and Particulate Matter,' held September 18-21, 2005, in Arlington, Virginia. The goal of the conference was to build on the discussions of the first four Air Quality Conferences, providing further opportunity for leading representatives of industry, government, research institutions, academia, and environmental organizations to discuss the key interrelationships between policy and science shaping near-term regulations and controls and to assist in moving forward on emerging issues that will lead to acceptable programs and policies to protectmore » human health, the environment, and economic growth. The conference was extremely timely, as it was the last large conference prior to publication of the U.S. Environmental Protection Agency's final regulations for mercury control from coal-fired utilities, and provided a forum to realistically assess the status of mercury controls in relation to the new regulations.« less
Mendoza, Jason A; Baker, K Scott; Moreno, Megan A; Whitlock, Kathryn; Abbey-Lambertz, Mark; Waite, Alan; Colburn, Trina; Chow, Eric J
2017-12-01
Physical activity (PA) may be important for preventing chronic diseases for adolescent and young adult (AYA) childhood cancer survivors. Randomized controlled trials (RCTs) of PA interventions for AYA survivors are sparse, but necessary to determine effective programs for increasing PA among this population. Thus, we conducted a pilot RCT, testing the feasibility of a mobile health (mHealth) intervention to promote PA among AYA survivors. We recruited 14- to 18-year-olds who were ≥1-year post cancer therapy from Seattle Children's Hospital. The 10-week intervention consisted of a wearable PA-tracking device (Fitbit Flex) and a peer-based virtual support group (Facebook group). Research staff helped set step goals and awarded badges weekly. Controls received usual care. Baseline assessments occurred before randomization and follow-up assessments occurred during weeks 8-10 of the intervention period. Feasibility criteria are defined below. Qualitative interviews assessed acceptability. Exploratory outcomes included PA, quality of life, and motivation for PA. All feasibility criteria were met: we recruited 60 survivors, intervention participants wore the Fitbit on the majority (71.5%) of intervention days, and ≥90% of all participants completed questionnaires. Qualitative data confirmed intervention acceptability. Exploratory analyses found no significant adjusted group differences for change in moderate-to-vigorous PA (4.4 vs. 5.0 min/day; P = 0.92) or sedentary time (-4.5 vs. 1.0 min/day; P = 0.73), comparing intervention subjects to controls. Some modest differences were found for select subscales of quality of life and motivation for PA. This mHealth PA intervention was feasible and acceptable to AYA childhood cancer survivors and warrants a fully powered RCT. © 2017 Wiley Periodicals, Inc.
Microbiological Spoilage of Spices, Nuts, Cocoa, and Coffee
NASA Astrophysics Data System (ADS)
Pinkas, Joan M.; Battista, Karen; Morille-Hinds, Theodora
Spices, nuts, cocoa, and coffee are raw materials that may be used alone or as ingredients in the manufacture of processed food products. The control of microbiological spoilage of these raw materials at the ingredient stage will enable the food processor to better assure the production of high-quality foods with an acceptable shelf life. While this chapter is limited to four materials, many of the spoilage control procedures recommended can also be applied to other raw materials of a similar nature.
Willems, Elise; Smismans, Annick; Cartuyvels, Reinoud; Coppens, Guy; Van Vaerenbergh, Kristien; Van den Abeele, Anne-Marie; Frans, Johan
2012-05-01
Bloodstream infections remain a major challenge in medicine. Optimal detection of pathogens is only possible if the quality of preanalytical factors is thoroughly controlled. Since the laboratory is responsible for this preanalytical phase, the quality control of critical factors should be integrated in its quality control program. The numerous recommendations regarding blood culture collection contain controversies. Only an unambiguous guideline permits standardization and interlaboratory quality control. We present an evidence-based concise guideline of critical preanalytical determinants for blood culture collection and summarize key performance indicators with their concomitant target values. In an attempt to benchmark, we compared the true-positive rate, contamination rate, and collected blood volume of blood culture bottles in 5 Belgian hospital laboratories. The true-positive blood culture rate fell within previously defined acceptation criteria by Baron et al. (2005) in all 5 hospitals, whereas the contamination rate exceeded the target value in 4 locations. Most unexpected, in each of the 5 laboratories, more than one third of the blood culture bottles were incorrectly filled, irrespective of the manufacturer of the blood culture vials. As a consequence of this shortcoming, one manufacturer recently developed an automatic blood volume monitoring system. In conclusion, clear recommendations for standardized blood culture collection combined with quality control of critical factors of the preanalytical phase are essential for diagnostic blood culture improvement. Copyright © 2012 Elsevier Inc. All rights reserved.
Measuring decision quality: psychometric evaluation of a new instrument for breast cancer surgery
2012-01-01
Background The purpose of this paper is to examine the acceptability, feasibility, reliability and validity of a new decision quality instrument that assesses the extent to which patients are informed and receive treatments that match their goals. Methods Cross-sectional mail survey of recent breast cancer survivors, providers and healthy controls and a retest survey of survivors. The decision quality instrument includes knowledge questions and a set of goals, and results in two scores: a breast cancer surgery knowledge score and a concordance score, which reflects the percentage of patients who received treatments that match their goals. Hypotheses related to acceptability, feasibility, discriminant validity, content validity, predictive validity and retest reliability of the survey instrument were examined. Results We had responses from 440 eligible patients, 88 providers and 35 healthy controls. The decision quality instrument was feasible to implement in this study, with low missing data. The knowledge score had good retest reliability (intraclass correlation coefficient = 0.70) and discriminated between providers and patients (mean difference 35%, p < 0.001). The majority of providers felt that the knowledge items covered content that was essential for the decision. Five of the 6 treatment goals met targets for content validity. The five goals had moderate to strong retest reliability (0.64 to 0.87). The concordance score was 89%, indicating that a majority had treatments concordant with that predicted by their goals. Patients who had concordant treatment had similar levels of confidence and regret as those who did not. Conclusions The decision quality instrument met the criteria of feasibility, reliability, discriminant and content validity in this sample. Additional research to examine performance of the instrument in prospective studies and more diverse populations is needed. PMID:22681763
Eigenstructure Assignment for Fault Tolerant Flight Control Design
NASA Technical Reports Server (NTRS)
Sobel, Kenneth; Joshi, Suresh (Technical Monitor)
2002-01-01
In recent years, fault tolerant flight control systems have gained an increased interest for high performance military aircraft as well as civil aircraft. Fault tolerant control systems can be described as either active or passive. An active fault tolerant control system has to either reconfigure or adapt the controller in response to a failure. One approach is to reconfigure the controller based upon detection and identification of the failure. Another approach is to use direct adaptive control to adjust the controller without explicitly identifying the failure. In contrast, a passive fault tolerant control system uses a fixed controller which achieves acceptable performance for a presumed set of failures. We have obtained a passive fault tolerant flight control law for the F/A-18 aircraft which achieves acceptable handling qualities for a class of control surface failures. The class of failures includes the symmetric failure of any one control surface being stuck at its trim value. A comparison was made of an eigenstructure assignment gain designed for the unfailed aircraft with a fault tolerant multiobjective optimization gain. We have shown that time responses for the unfailed aircraft using the eigenstructure assignment gain and the fault tolerant gain are identical. Furthermore, the fault tolerant gain achieves MIL-F-8785C specifications for all failure conditions.
Durand, Marie-Anne; Gates, Bob; Parkes, Georgina; Zia, Asif; Friedli, Karin; Barton, Garry; Ring, Howard; Oostendorp, Linda; Wellsted, David
2014-11-20
Epilepsy is the most common neurological problem that affects people with learning disabilities. The high seizure frequency, resistance to treatments, associated skills deficit and co-morbidities make the management of epilepsy particularly challenging for people with learning disabilities. The Books Beyond Words booklet for epilepsy uses images to help people with learning disabilities manage their condition and improve quality of life. Our aim is to conduct a randomized controlled feasibility trial exploring key methodological, design and acceptability issues, in order to subsequently undertake a large-scale randomized controlled trial of the Books Beyond Words booklet for epilepsy. We will use a two-arm, single-centre randomized controlled feasibility design, over a 20-month period, across five epilepsy clinics in Hertfordshire, United Kingdom. We will recruit 40 eligible adults with learning disabilities and a confirmed diagnosis of epilepsy and will randomize them to use either the Books Beyond Words booklet plus usual care (intervention group) or to receive routine information and services (control group). We will collect quantitative data about the number of eligible participants, number of recruited participants, demographic data, discontinuation rates, variability of the primary outcome measure (quality of life: Epilepsy and Learning Disabilities Quality of Life scale), seizure severity, seizure control, intervention's patterns of use, use of other epilepsy-related information, resource use and the EQ-5D-5L health questionnaire. We will also gather qualitative data about the feasibility and acceptability of the study procedures and the Books Beyond Words booklet. Ethical approval for this study was granted on 28 April 2014, by the Wales Research Ethics Committee 5. Recruitment began on 1 July 2014. The outcomes of this feasibility study will be used to inform the design and methodology of a definitive study, adequately powered to determine the impact of the Books Beyond Words intervention to improve the management of epilepsy in people with learning disabilities. http://ISRCTN80067039 (Date of ISRCTN assignation: 23 April 2014).
Improved quality control of [18F]fluoromethylcholine.
Nader, Michael; Reindl, Dietmar; Eichinger, Reinhard; Beheshti, Mohsen; Langsteger, Werner
2011-11-01
With respect to the broad application of [(18)F-methyl]fluorocholine (FCH), there is a need for a safe, but also efficient and convenient way for routine quality control of FCH. Therefore, a GC- method should be developed and validated which allows the simultaneous quantitation of all chemical impurities and residual solvents such as acetonitrile, ethanol, dibromomethane and N,N-dimethylaminoethanol. Analytical GC has been performed with a GC-capillary column Optima 1701 (50 m×0.32 mm), and a pre-column deactivated capillary column phenyl-Sil (10 m×0.32) in line with a flame ionization detector (FID) was used. The validation includes the following tests: specificity, range, accuracy, linearity, precision, limit of detection (LOD) and limit of quantitation (LOQ) of all listed substances. The described GC method has been successfully used for the quantitation of the listed chemical impurities. The specificity of the GC separation has been proven by demonstrating that the appearing peaks are completely separated from each other and that a resolution R≥1.5 for the separation of the peaks could be achieved. The specified range confirmed that the analytical procedure provides an acceptable degree of linearity, accuracy and precision. For each substance, a range from 2% to 120% of the specification limit could be demonstrated. The corresponding LOD values were determined and were much lower than the specification limits. An efficient and convenient GC method for the quality control of FCH has been developed and validated which meets all acceptance criteria in terms of linearity, specificity, precision, accuracy, LOD and LOQ. Copyright © 2011 Elsevier Inc. All rights reserved.
Wallace, Adam N; Vyhmeister, Ross; Bagade, Swapnil; Chatterjee, Arindam; Hicks, Brandon; Ramirez-Giraldo, Juan Carlos; McKinstry, Robert C
2015-06-01
Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.
Fundamentals of Acoustic Measurements on Trees and Logs and Their Implication to Field Application
Xiping Wang
2011-01-01
Acoustic technologies have been well established as material evaluation tools in the past several decades, and their use has become widely accepted in the forest products industry for on-line quality control and products grading. Recent research developments on acoustic sensing technology offer further opportunities to evaluate standing trees and logs for general wood...
Assessment of the Physicochemical Quality of Drinking Water Resources in the Central Part of Iran.
Nikaeen, Mahnaz; Shahryari, Ali; Hajiannejad, Mehdi; Saffari, Hossein; Kachuei, Zahra Moosavian; Hassanzadeh, Akbar
2016-01-01
The aim of the study described in this article was to assess the physicochemical quality of water resources in Isfahan province, located in the central part of Iran, from June to November 2012. Comparison of the results with the acceptable limits recommended by the World Health Organization (WHO) for drinking water showed that nitrate, chloride, iron, and fluoride concentrations exceeded the maximum acceptable level in 12.3%, 9.2%, 6.8%, and 1.5% of samples, respectively. Total dissolved solids (TDS) and turbidity values also exceeded the maximum acceptable level in 9.2% and 3.1% of samples, respectively. In general, the quality of drinking water resources in the central part of Iran at present is mostly acceptable and satisfactory. It may be deteriorated in the future, however, because water quantity and quality in arid and semiarid areas are highly variable over time. Therefore, continued monitoring of the water resources quality is extremely important to environmental safety.
NASA Technical Reports Server (NTRS)
Perry, J. L.; James, J. T.; Cole, H. E.; Limero, T. F.; Beck, S. W.
1997-01-01
Collection and analysis of spacecraft cabin air samples are necessary to assess the cabin air quality with respect to crew health. Both toxicology and engineering disciplines work together to achieve an acceptably clean cabin atmosphere. Toxicology is concerned with limiting the risk to crew health from chemical sources, setting exposure limits, and analyzing air samples to determine how well these limits are met. Engineering provides the means for minimizing the contribution of the various contaminant generating sources by providing active contamination control equipment on board spacecraft and adhering to a rigorous material selection and control program during the design and construction of the spacecraft. A review of the rationale and objectives for sampling spacecraft cabin atmospheres is provided. The presently-available sampling equipment and methods are reviewed along with the analytical chemistry methods employed to determine trace contaminant concentrations. These methods are compared and assessed with respect to actual cabin air quality monitoring needs. Recommendations are presented with respect to the basic sampling program necessary to ensure an acceptably clean spacecraft cabin atmosphere. Also, rationale and recommendations for expanding the scope of the basic monitoring program are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hollister, R
QC sample results (daily background check drum and 100-gram SGS check drum) were within acceptance criteria established by WIPP's Quality Assurance Objectives for TRU Waste Characterization. Replicate runs were performed on drum LL85501243TRU. Replicate measurement results are identical at the 95% confidence level as established by WIPP criteria. HWM NCAR No. 02-1000168 issued on 17-Oct-2002 regarding a partially dislodged Cd sheet filter on the HPGe coaxial detector. This physical geometry occurred on 01-Oct-2002 and was not corrected until 10-Oct-2002, during which period is inclusive of the present batch run of drums. Per discussions among the Independent Technical Reviewer, Expert Reviewermore » and the Technical QA Supervisor, as well as in consultation with John Fleissner, Technical Point of Contact from Canberra, the analytical results are technically reliable. All QC standard runs during this period were in control. Data packet for SGS Batch 2002-13 generated using passive gamma-ray spectroscopy with the Pu Facility SGS unit is technically reasonable. All QC samples are in compliance with establiShed control limits. The batch data packet has been reviewed for correctness, completeness, consistency and compliance with WIPP's Quality Assurance Objectives and determined to be acceptable.« less
Babaie, Javad; Ardalan, Ali; Vatandoost, Hasan; Goya, Mohammad Mehdi; Akbari Sari, Ali
2015-08-01
Following the twin earthquakes on August 11, 2012, in the East Azerbaijan province of Iran, the provincial health center set up a surveillance system to monitor communicable diseases. This study aimed to assess the performance of this surveillance system. In this quantitative-qualitative study, performance of the communicable diseases surveillance system was assessed by using the updated guidelines of the Centers for Disease Control and Prevention (CDC). Qualitative data were collected through interviews with the surveillance system participants, and quantitative data were obtained from the surveillance system. The surveillance system was useful, simple, representative, timely, and flexible. The data quality, acceptability, and stability of the surveillance system were 65.6%, 10.63%, and 100%, respectively. The sensitivity and positive predictive value were not calculated owing to the absence of a gold standard. The surveillance system satisfactorily met the goals expected for its setup. The data obtained led to the control of communicable diseases in the affected areas. Required interventions based on the incidence of communicable disease were designed and implemented. The results also reassured health authorities and the public. However, data quality and acceptability should be taken into consideration and reviewed for implementation in future disasters.
Quality and sensory acceptability of a chilled functional apple ready-dessert.
Keenan, D F; Brunton, N P; Gormley, T R; Butler, F
2012-04-01
An apple and dairy based ready-dessert with an added prebiotic was stored and chill temperatures and number of quality attributes were monitored during chill (4 °C) storage for 30 days. All ready-desserts were thermally processed by sous vide (P (90) > 10 min). The stability of the dairy component in ready-desserts was monitored by measuring volatile free fatty acids. Changes in these components were more evident in prebiotic-enriched samples compared to controls. However, no significant differences were observed over storage in control and prebiotic-enriched ready-desserts. This was supported by sensory analysis that showed no significant changes over storage in control or prebiotic-enriched samples. Of the other quality parameters, the addition of prebiotic inclusions resulted in lower L and b values and dry matter (p < 0.05), while increasing (p < 0.05) soluble solids content compared to control samples. Fluctuations in some of the quality parameters were also observed over storage. Rheological characteristics, i.e. flow behaviour (n), consistency index (K), storage (G'), loss (G″) and complex (G*) moduli were unaffected by prebiotic inclusion. However, storage affected the rheological characteristics of ready-desserts. A decrease (p < 0.05) in flow behaviour (n) led to concomitant increases in consistency index (K) and complex modulus (G*) values in control samples.
Frandes, Mirela; Deiac, Anca V; Timar, Bogdan; Lungeanu, Diana
2017-01-01
Background Nowadays, mobile technologies are part of everyday life, but the lack of instruments to assess their acceptability for the management of chronic diseases makes their actual adoption for this purpose slow. Objective The objective of this study was to develop a survey instrument for assessing patients’ attitude toward and intention to use mobile technology for diabetes mellitus (DM) self-management, as well as to identify sociodemographic characteristics and quality of life factors that affect them. Methods We first conducted the documentation and instrument design phases, which were subsequently followed by the pilot study and instrument validation. Afterward, the instrument was administered 103 patients (median age: 37 years; range: 18–65 years) diagnosed with type 1 or type 2 DM, who accepted to participate in the study. The reliability and construct validity were assessed by computing Cronbach’s alpha and using factor analysis, respectively. Results The instrument included statements about the actual use of electronic devices for DM management, interaction between patient and physician, attitude toward using mobile technology, and quality of life evaluation. Cronbach’s alpha was 0.9 for attitude toward using mobile technology and 0.97 for attitude toward using mobile device applications for DM self-management. Younger patients (Spearman’s ρ=−0.429; P<0.001) with better glycemic control (Spearman’s ρ=−0.322; P<0.001) and higher education level (Kendall’s τ=0.51; P<0.001) had significantly more favorable attitude toward using mobile assistive applications for DM control. Moreover, patients with a higher quality of life presented a significantly more positive attitude toward using modern technology (Spearman’s ρ=0.466; P<0.001). Conclusion The instrument showed good reliability and internal consistency, making it suitable for measuring the acceptability of mobile technology for DM self-management. Additionally, we found that even if most of the patients showed positive attitude toward mobile applications, only a moderate level of intention to indeed use them was observed. Moreover, the study indicated that barriers were truthfulness and easiness to use. PMID:28243069
Quality Assurance of Samples and Processes in the Spanish Renal Research Network (REDinREN) Biobank.
Calleros-Basilio, Laura; Cortés, María Alicia; García-Jerez, Andrea; Luengo-Rodríguez, Alicia; Orozco-Agudo, Ana; Valdivielso, José Manuel; Rodríguez-Puyol, Diego; Rodríguez-Puyol, Manuel
2016-12-01
Biobanks are useful platforms to build bridges between basic, translational, and clinical research and clinical care. They are repositories of high-quality human biological samples ideal for evaluating their histological characteristics and also their genome, transcriptome, and proteome. The Spanish Renal Research Network Biobank contains more than 76,500 well-preserved frozen samples of a wide variety of kidney diseases, collected from 5450 patients seen by over 70 nephrology services throughout the Spanish territory. To determine and to report the results of the quality control of samples and processes conducted in our biobank, implemented in accordance with the requirements of the ISO 9001:2008 international standard. Two types of quality controls were performed: (1) systematic, that is, measurement of viable peripheral blood mononuclear cells (PBMCs) obtained and purity of nucleic acids and (2) ad-hoc, that is, viability of thawed PBMC, DNA extraction process reproducibility, and the integrity and functionality of nucleic acids, implemented on a routine basis. PBMC isolation by Ficoll yielded reproducible results and its cryopreserved viability was >90%. Acceptable A260/A280 ratios were obtained for the vast majority of the DNA (n = 2328) and RNA (n = 78) samples analyzed. DNA integrity was demonstrated by agarose gels and by β-globulin gene polymerase chain reaction (PCR) amplification of 1327 and 989 bp fragments. DNA of acceptable quality had at least three bands of β-globulin amplified obtained (n = 26/30). RNA integrity number (RIN) determinations obtained RIN numbers ≥7 (n = 87/96). The amplifiability of nucleic acids was confirmed by qPCR and RT-qPCR of β-actin and GAPDH genes. Long storage or delayed processing time did not affect the quality of the samples analyzed. The processes of DNA extraction also yielded reproducible results. These results clearly indicate that our PBMC, DNA, and RNA stored samples meet the required quality standards to be used for biomedical research, ensuring their long-term preservation.
Lorca, T A; Gingerich, T M; Pierson, M D; Flick, G J; Hackney, C R; Sumner, S S
2001-12-01
The objective of this study was to determine the effect of normal microflora and Morganella morganii on histamine formation and olfactory acceptability in raw bluefish under controlled storage conditions. Fillets inoculated with and without M. morganii were stored at 5, 10, and 15 degrees C for 7 days. Microbial isolates from surface swabs were identified and screened for histidine decarboxylase activity. Olfactory acceptance was performed by an informal sensory panel. Histamine levels were quantified using high-performance liquid chromatography and fluorescence detection. While olfactory acceptance decreased, histamine concentration and bacterial counts increased. Storage temperature had a significant effect on histamine levels, bacterial counts, and olfactory acceptance of the bluefish. Inoculation with M. morganii had a positive significant effect on histamine formation for bluefish held at 10 and 15 degrees C (P < 0.0001). The results of the study will serve in supporting U.S. Food and Drug Administration (FDA) regulations regarding guidance and hazard levels of histamine in fresh bluefish.
Nayak, Prakash Chandra; Raju, C V; Lakshmisha, I P; Singh, Rajkumar Ratankumar; Sofi, Faisal Rashid
2015-06-01
The ability of button mushroom (Agaricus bisporus) in changing physical, chemical, microbial and sensory properties of fish patties prepared from sutchi catfish (Pangasius hypophthalmus) was investigated. Two batches of fresh patties were prepared, one batch was treated with 15 % button mushroom (TP) and other batch was a control (CP) without mushroom. The patties were packed in polythene bags and stored under refrigerated condition (6 ± 2 ºC) without adding any preservatives for the estimation of storage stability. The analyses of patties were conducted at regular intervals of 3 days. The results showed that, Peroxide value, Thiobarbituric acid value, Free fatty acids increased significantly in CP at the end of 12 days whereas the TP was within the acceptable limit up to 16 days. Total volatile base nitrogen and Trimethylamine nitrogen also showed a similar trend. The Total plate count and Aerobic spore formers showed an increasing trend in CP when compared to TP. The sensory scores showed that the overall acceptability of CP were lower than TP, which was acceptable even after 16 days of storage. The present study showed that, the quality and storage stability of TP were observed to be in good condition up to 16 days and started deteriorating 20th day onwards, whereas the CP were acceptable only up to 12 days. Therefore it can be recommended that, addition of 15 % of button mushroom to sutchi catfish patty not only increases the nutritional quality but also increases the shelf life of patties under refrigerated storage.
Managing Neuropsychological Impairment in Multiple Sclerosis
Lau, Stephanie; Penner, Iris; Heesen, Christoph; Moritz, Steffen
2015-01-01
Background: Multiple sclerosis (MS) is an inflammatory and neurodegenerative disease of the central nervous system of potential autoimmune origin that is frequently associated with psychological disorders and cognitive deficits, as well as with fatigue, stress, and psychosocial burden. These factors often cause decreased quality of life, social withdrawal, and unemployment. We describe the development of a cognitive-behavioral group intervention based on the concept of metacognition and evaluation of the feasibility and acceptance of the program as a rehabilitation tool. Methods: Metacognitive Training in MS (MaTiMS) consists of six modules, each 90 minutes in duration. We tested acceptance and design of the program in six focus groups (entire sample, n = 27). Framework analysis of transcripts was used to identify key topics and categories. Program modules were revised in accordance with appropriate recommendations of focus group members. We subsequently evaluated MaTiMS in two groups (n = 5, n = 6) in a rehabilitation center. Neuropsychological functioning as well as coping self-efficacy, depression, stress, perceived cognitive deficit, fatigue, and quality of life were assessed. Acceptance of MaTiMS from the patient perspective was also studied. Results: The modules were highly accepted by patients. Pre-post assessments showed significant improvements in the Coping Self Efficacy Scale (P = .007), the Würzburger Fatigue Inventory for MS Score (P = .028), and the Hamburg Quality of Life Questionnaire in Multiple Sclerosis Mood subscale (P = .046). Conclusions: These preliminary results suggest that MaTiMS represents a feasible psychological group training program that may foster improvements in self-efficacy, fatigue, and mood. The next step will be an evaluation of the program in a randomized controlled trial. PMID:26052258
Orta Mira, Nieves; Serrano, María del Remedio Guna; Martínez, José-Carlos Latorre; Ovies, María Rosario; Poveda, Marta; de Gopegui, Enrique Ruiz; Cardona, Concepción Gimeno
2011-12-01
Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most important markers for the follow-up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of the results obtained by microbiology laboratories. This article summarized the results obtained in the 2010 External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology for HIV-1, HCV, and HBV viral loads and HCV genotyping. In the HIV-1 program, a total of five standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 3-5 log(10) copies/mL; two of these standards were identical, with the aim of determining repeatability. A significant proportion of the laboratories (22.6% on average) obtained values out of the accepted range (mean ± 0.2 log(10)copies/mL), depending on the standard and on the method used for quantification. Repeatability was very good, with up to 95% of laboratories reporting results within the limits (Δ<0.5 log(10)copies/mL). The HBV and HCV program consisted of two standards with different viral load contents. Most of the participants, 86.1% in the case of HCV and 87.1% in HBV, obtained all the results within the accepted range (mean ± 1.96 SD log(10)UI/mL). Post-analytical errors due to mistranscription of the results were detected in these controls. Data from this analysis reinforce the utility of proficiency programs to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase in overall quality. Due to interlaboratory variability, use of the same method and the same laboratory for patient follow-up is advisable. Copyright © 2011 Elsevier España S.L. All rights reserved.
Dewa, Carolyn S; Loong, Desmond; Bonato, Sarah; Trojanowski, Lucy
2017-01-01
Objectives This study reviews the current state of the published peer-reviewed literature related to physician burnout and two quality of care dimensions. The purpose of this systematic literature review is to address the question, ‘How does physician burnout affect the quality of healthcare related to the dimensions of acceptability and safety?’ Design Using a multiphase screening process, this systematic literature review is based on publically available peer-reviewed studies published between 2002 and 2017. Six electronic databases were searched: (1) MEDLINE Current, (2) MEDLINE In-process, (3) MEDLINE Epub Ahead of Print, (4) PsycINFO, (5) Embase and (6) Web of Science. Setting Physicians practicing in civilian settings. Participants Practicing physicians who have completed training. Primary and secondary outcome measures Quality of healthcare related to acceptability (ie, patient satisfaction, physician communication and physician attitudes) and safety (ie, minimising risks or harm to patients). Results 4114 unique citations were identified. Of these, 12 articles were included in the review. Two studies were rated as having high risk of bias and 10 as having moderate risk. Four studies were conducted in North America, four in Europe, one in the Middle East and three in East Asia. Results of this systematic literature review suggest there is moderate evidence that burnout is associated with safety-related quality of care. Because of the variability in the way patient acceptability-related quality of care was measured and the inconsistency in study findings, the evidence supporting the relationship between burnout and patient acceptability-related quality of care is less strong. Conclusions The focus on direct care-related quality highlights additional ways that physician burnout affects the healthcare system. These studies can help to inform decisions about how to improve patient care by addressing physician burnout. Continued work looking at the relationship between dimensions of acceptability-related quality of care measures and burnout is needed to advance the field. PMID:28637730
Quality Aware Compression of Electrocardiogram Using Principal Component Analysis.
Gupta, Rajarshi
2016-05-01
Electrocardiogram (ECG) compression finds wide application in various patient monitoring purposes. Quality control in ECG compression ensures reconstruction quality and its clinical acceptance for diagnostic decision making. In this paper, a quality aware compression method of single lead ECG is described using principal component analysis (PCA). After pre-processing, beat extraction and PCA decomposition, two independent quality criteria, namely, bit rate control (BRC) or error control (EC) criteria were set to select optimal principal components, eigenvectors and their quantization level to achieve desired bit rate or error measure. The selected principal components and eigenvectors were finally compressed using a modified delta and Huffman encoder. The algorithms were validated with 32 sets of MIT Arrhythmia data and 60 normal and 30 sets of diagnostic ECG data from PTB Diagnostic ECG data ptbdb, all at 1 kHz sampling. For BRC with a CR threshold of 40, an average Compression Ratio (CR), percentage root mean squared difference normalized (PRDN) and maximum absolute error (MAE) of 50.74, 16.22 and 0.243 mV respectively were obtained. For EC with an upper limit of 5 % PRDN and 0.1 mV MAE, the average CR, PRDN and MAE of 9.48, 4.13 and 0.049 mV respectively were obtained. For mitdb data 117, the reconstruction quality could be preserved up to CR of 68.96 by extending the BRC threshold. The proposed method yields better results than recently published works on quality controlled ECG compression.
Breaking the news on mobile TV: user requirements of a popular mobile content
NASA Astrophysics Data System (ADS)
Knoche, Hendrik O.; Sasse, M. Angela
2006-02-01
This paper presents the results from three lab-based studies that investigated different ways of delivering Mobile TV News by measuring user responses to different encoding bitrates, image resolutions and text quality. All studies were carried out with participants watching News content on mobile devices, with a total of 216 participants rating the acceptability of the viewing experience. Study 1 compared the acceptability of a 15-second video clip at different video and audio encoding bit rates on a 3G phone at a resolution of 176x144 and an iPAQ PDA (240x180). Study 2 measured the acceptability of video quality of full feature news clips of 2.5 minutes which were recorded from broadcast TV, encoded at resolutions ranging from 120x90 to 240x180, and combined with different encoding bit rates and audio qualities presented on an iPAQ. Study 3 improved the legibility of the text included in the video simulating a separate text delivery. The acceptability of News' video quality was greatly reduced at a resolution of 120x90. The legibility of text was a decisive factor in the participants' assessment of the video quality. Resolutions of 168x126 and higher were substantially more acceptable when they were accompanied by optimized high quality text compared to proportionally scaled inline text. When accompanied by high quality text TV news clips were acceptable to the vast majority of participants at resolutions as small as 168x126 for video encoding bitrates of 160kbps and higher. Service designers and operators can apply this knowledge to design a cost-effective mobile TV experience.
Jeon, Ju-Hyun; Cho, Chong-Kwan; Park, So-Jung; Kang, Hwi-Joong; Kim, Kyungmin; Jung, In-Chul; Kim, Young-Il; Lee, Suk-Hoon; Yoo, Hwa-Seung
2017-03-01
The aim of this study was to determine the feasibility, acceptability, and safety of using moxibustion for treating anorexia and improving quality of life in patients with metastatic cancer. We conducted a randomized sham-controlled trial of moxibustion. Sixteen patients with metastatic cancer were recruited from Daejeon, South Korea. The patients were randomly placed into a true or a sham moxibustion group and received 10 true or sham moxibustion treatments administered to the abdomen (CV12, CV8, CV4) and legs (ST36) over a 2-week period. Outcome measures included interest in participating in the trial, identification of successful recruitment strategies, the appropriateness of eligibility criteria, and compliance with the treatment plan (ie, attendance at treatment sessions). Clinical outcomes included results of the Functional Assessment of Anorexia/Cachexia Therapy (FAACT), answers on the European Organization for Research and Treatment of Cancer 30-item core quality of life (EORTC QLQ-C30) questionnaires, scores on the visual analogue scale (VAS), and the results from blood tests and a safety evaluation. Moxibustion was an acceptable intervention in patients with metastatic cancer. Compliance with the treatment protocol was high, with 11 patients completing all 10 treatments. No serious adverse events related to moxibustion occurred, but 4 patients in the true moxibustion group reported mild rubefaction, which disappeared in a few hours. This study suggests that moxibustion may be safely used to treat anorexia and improve quality of life in patients with metastatic cancer. However, further research is needed to confirm this result.
Mathany, Timothy M.; Land, Michael; Belitz, Kenneth
2008-01-01
Ground-water quality in the approximately 860 square-mile Coastal Los Angeles Basin study unit (CLAB) was investigated from June to November of 2006 as part of the Statewide Basin Assessment Project of the Ground-Water Ambient Monitoring and Assessment (GAMA) Program. The GAMA Statewide Basin Assessment was developed in response to the Ground-Water Quality Monitoring Act of 2001, and is being conducted by the U.S. Geological Survey (USGS) in cooperation with the California State Water Resources Control Board (SWRCB). The Coastal Los Angeles Basin study was designed to provide a spatially unbiased assessment of raw ground-water quality within CLAB, as well as a statistically consistent basis for comparing water quality throughout California. Samples were collected from 69 wells in Los Angeles and Orange Counties. Fifty-five of the wells were selected using a spatially distributed, randomized grid-based method to provide statistical representation of the study area (?grid wells?). Fourteen additional wells were selected to evaluate changes in ground-water chemistry or to gain a greater understanding of the ground-water quality within a specific portion of the Coastal Los Angeles Basin study unit ('understanding wells'). Ground-water samples were analyzed for: a large number of synthetic organic constituents [volatile organic compounds (VOCs), gasoline oxygenates and their degradates, pesticides, polar pesticides, and pesticide degradates, pharmaceutical compounds, and potential wastewater-indicators]; constituents of special interest [perchlorate, N-nitrosodimethylamine (NDMA), 1,4-dioxane, and 1,2,3-trichloropropane (1,2,3-TCP)]; inorganic constituents that can occur naturally [nutrients, major and minor ions, and trace elements]; radioactive constituents [gross-alpha and gross-beta radiation, radium isotopes, and radon-222]; and microbial indicators. Naturally occurring isotopes [stable isotopic ratios of hydrogen and oxygen, and activities of tritium and carbon-14] and dissolved noble gases also were measured to help identify the sources and ages of the sampled ground water. Quality-control samples (blanks, replicates, and samples for matrix spikes) were collected at approximately one-fourth of the wells, and the results for these samples were used to evaluate the quality of the data for the ground-water samples. Field blanks rarely contained detectable concentrations of any constituent, suggesting that contamination was not a significant source of bias. Differences between replicate samples were within acceptable ranges, indicating acceptably low variability. Matrix spike recoveries were within acceptable ranges for most compounds. Assessment of the quality-control information resulted in applying ?V? codes to approximately 0.1 percent of the data collected for ground-water samples (meaning a constituent was detected in blanks as well as the corresponding environmental data). This study did not attempt to evaluate the quality of drinking water delivered to consumers; after withdrawal from the ground, water typically is treated, disinfected, and (or) blended with other waters to maintain acceptable drinking-water quality. Regulatory thresholds are applied to the treated drinking water that is served to the consumer, not to raw ground water. However, to provide some context for the results, concentrations of constituents measured in the raw ground water were compared with regulatory and non-regulatory health-based thresholds established by the U.S. Environmental Protection Agency (USEPA), California Department of Public Health (CDPH, formerly California Department of Health Services [CADHS]) and thresholds established for aesthetic concerns (secondary maximum contaminant levels, SMCL-CA) by CDPH. Comparisons between data collected for this study and drinking-water thresholds are for illustrative purposes only, and are not indicative of compliance or non-compliance with those thresholds. VOCs were detected in alm
Toward a perceptual video-quality metric
NASA Astrophysics Data System (ADS)
Watson, Andrew B.
1998-07-01
The advent of widespread distribution of digital video creates a need for automated methods for evaluating the visual quality of digital video. This is particularly so since most digital video is compressed using lossy methods, which involve the controlled introduction of potentially visible artifacts. Compounding the problem is the bursty nature of digital video, which requires adaptive bit allocation based on visual quality metrics, and the economic need to reduce bit-rate to the lowest level that yields acceptable quality. In previous work, we have developed visual quality metrics for evaluating, controlling,a nd optimizing the quality of compressed still images. These metrics incorporate simplified models of human visual sensitivity to spatial and chromatic visual signals. Here I describe a new video quality metric that is an extension of these still image metrics into the time domain. Like the still image metrics, it is based on the Discrete Cosine Transform. An effort has been made to minimize the amount of memory and computation required by the metric, in order that might be applied in the widest range of applications. To calibrate the basic sensitivity of this metric to spatial and temporal signals we have made measurements of visual thresholds for temporally varying samples of DCT quantization noise.
Lange, Rogier; Ter Heine, Rob; van der Gronde, Toon; Selles, Suzanne; de Klerk, John; Bloemendal, Haiko; Hendrikse, Harry
2016-07-30
Rhenium-188-HEDP ((188)Re-HEDP) is a therapeutic radiopharmaceutical for treatment of osteoblastic bone metastases. No standard procedure for the preparation of this radiopharmaceutical is available. Preparation conditions may influence the quality and in vivo behaviour of this product. In this study we investigate the effect of critical process parameters on product quality and stability of (188)Re-HEDP. A stepwise approach was used, based on the quality by design (QbD) concept of the ICH Q8 (Pharmaceutical Development) guideline. Potential critical process conditions were identified. Variables tested were the elution volume, the freshness of the eluate, the reaction temperature and time, and the stability of the product upon dilution and storage. The impact of each variable on radiochemical purity was investigated. The acceptable ranges were established by boundary testing. With 2ml eluate, adequate radiochemical purity and stability were found. Nine ml eluate yielded a product that was less stable. Using eluate stored for 24h resulted in acceptable radiochemical purity. Complexation for 30min at room temperature, at 60°C and at 100°C generated appropriate and stable products. A complexation time of 10min at 90°C was too short, whereas heating 60min resulted in products that passed quality control and were stable. Diluting the end product and storage at 32.5°C resulted in notable decomposition. Two boundary tests, an elution volume of 9ml and a heating time of 10min, yielded products of inadequate quality or stability. The product was found to be instable after dilution or when stored above room temperature. Our findings show that our previously developed preparation method falls well within the proven acceptable ranges. Applying QbD principles is feasible and worthwhile for the small-scale preparation of radiopharmaceuticals. Copyright © 2016 Elsevier B.V. All rights reserved.
Biology and genetic engineering of fruit maturation for enhanced quality and shelf-life.
Matas, Antonio J; Gapper, Nigel E; Chung, Mi-Young; Giovannoni, James J; Rose, Jocelyn K C
2009-04-01
Commercial regulation of ripening is currently achieved through early harvest, by controlling the postharvest storage atmosphere and genetic selection for slow or late ripening varieties. Although these approaches are often effective, they are not universally applicable and often result in acceptable, but poor quality, products. With increased understanding of the molecular biology underlying ripening and the advent of genetic engineering technologies, researchers have pursued new strategies to address problems in fruit shelf-life and quality. These have been guided by recent insights into mechanisms by which ethylene and a complex network of transcription factors regulate ripening, and by an increased appreciation of factors that contribute to shelf-life, such as the fruit cuticle.
Code of Federal Regulations, 2012 CFR
2012-07-01
... level and passing and failing criteria for Selective Enforcement Audits. 86.610-98 Section 86.610-98... quality level and passing and failing criteria for Selective Enforcement Audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed vehicle is one whose final deteriorated test results...
Code of Federal Regulations, 2010 CFR
2010-07-01
... level and passing and failing criteria for Selective Enforcement Audits. 86.610-98 Section 86.610-98... quality level and passing and failing criteria for Selective Enforcement Audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed vehicle is one whose final deteriorated test results...
Code of Federal Regulations, 2011 CFR
2011-07-01
... level and passing and failing criteria for Selective Enforcement Audits. 86.610-98 Section 86.610-98... quality level and passing and failing criteria for Selective Enforcement Audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed vehicle is one whose final deteriorated test results...
Code of Federal Regulations, 2013 CFR
2013-07-01
... level and passing and failing criteria for Selective Enforcement Audits. 86.610-98 Section 86.610-98... quality level and passing and failing criteria for Selective Enforcement Audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed vehicle is one whose final deteriorated test results...
ERIC Educational Resources Information Center
Nworji, Alexander O.
2013-01-01
Most organizations spend millions of dollars due to the impact of improperly implemented database application systems as evidenced by poor data quality problems. The purpose of this quantitative study was to use, and extend, the technology acceptance model (TAM) to assess the impact of information quality and technical quality factors on database…
Francis, Mark Rohit; Nagarajan, Guru; Sarkar, Rajiv; Mohan, Venkata Raghava; Kang, Gagandeep; Balraj, Vinohar
2015-07-30
Acceptance and long-term sustainability of water quality interventions are pivotal to realizing continued health benefits. However, there is limited research attempting to understand the factors that influence compliance to or adoption of such interventions. Eight focus group discussions with parents of young children--including compliant and not compliant households participating in an intervention study, and three key-informant interviews with village headmen were conducted between April and May 2014 to understand perceptions on the effects of unsafe water on health, household drinking water treatment practices, and the factors influencing acceptance and sustainability of an ongoing water quality intervention in a rural population of southern India. The ability to recognize health benefits from the intervention, ease of access to water distribution centers and the willingness to pay for intervention maintenance were factors facilitating acceptance and sustainability of the water quality intervention. On the other hand, faulty perceptions on water treatment, lack of knowledge about health hazards associated with drinking unsafe water, false sense of protection from locally available water, resistance to change in taste or odor of water and a lack of support from male members of the household were important factors impeding acceptance and long term use of the intervention. This study highlights the need to effectively involve communities at important stages of implementation for long term success of water quality interventions. Timely research on the factors influencing uptake of water quality interventions prior to implementation will ensure greater acceptance and sustainability of such interventions in low income settings.
The Marriage Checkup: A Randomized Controlled Trial of Annual Relationship Health Checkups
Cordova, James V.; Fleming, C.J. Eubanks; Morrill, Melinda Ippolito; Hawrilenko, Matt; Sollenberger, Julia W.; Harp, Amanda G.; Gray, Tatiana D.; Darling, Ellen V.; Blair, Jonathan M.; Meade, Amy E.; Wachs, Karen
2014-01-01
Objective This study assessed the efficacy of the Marriage Checkup for improving relationship health and intimacy. Method Cohabiting married couples (N=215, Mage women=44.5 years, men=47 years, 93.1% Caucasian) recruited from a northeastern U.S. metropolitan area through print and electronic media were randomly assigned to MC treatment or wait-list control. Treatment but not control couples participated in assessment and feedback visits, at the beginning of the study and again one year later. All couples completed nine sets of questionnaires over two years. Outcome measures included the Quality of Marriage Index, the Global Distress subscale of the Marital Satisfaction Inventory-Revised, the Intimate Safety Questionnaire, and the Relational Acceptance Questionnaire. Results A latent growth curve model indicated significant between group differences in intimacy at every measurement point after baseline (d ranged from .20 to .55, Md = .37), significant between group differences in women’s felt acceptance for every measurement point after baseline (d ranged from .17 to .47, Md = .34), significant between group differences in men’s felt acceptance through the 1-year-2 week follow-up (d across follow-up ranged from .11 to .40, Md = .25), and significant between group differences in relationship distress through 1-year 6-month follow-up (d across follow-up ranged from .11 to .39, Md = .23). Conclusions Longitudinal analysis of the MC supports the hypothesis that the MC significantly improves intimacy, acceptance, and satisfaction. Implications for dissemination are discussed. PMID:24932565
PACS quality control and automatic problem notifier
NASA Astrophysics Data System (ADS)
Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.
1997-05-01
One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established as are expected on other equipment used in the diagnostic process.
Guidelines to implement quality management systems in microbiology laboratories for tissue banking.
Vicentino, W; Rodríguez, G; Saldías, M; Alvarez, I
2009-10-01
Human tissues for implants are a biomedical product that is being used more frequently by many medical disciplines. There are infections in the patients related to the implanted tissues. The early detection of infections transmitted by blood and the microbiological study of tissues before their clinical use are strategies in tissue banks to prevent these situations. This work sought to contribute to establish the bases for the operation of a laboratory applied to the microbiological quality control of tissues. Based on classical microbiological principles, we defined the operation of microbiological control and tissues sterilization since 2003. We determine lists of acceptable microorganisms for every tissue, criteria for the interpretation of results, and a diagnostic algorithm of microbiological quality. We observed that the circumstances of donor death can be a determinant of the quality. The environment and the operator should be investigated as probable sources of contamination in outbreaks. The criteria of work based on a solid methodology must help to avoid the transmission of infections between donor and recipient. This is a critical point in the quality management of a tissue bank.
AIR CLEANING FOR ACCEPTABLE INDOOR AIR QUALITY
The paper discusses air cleaning for acceptable indoor air quality. ir cleaning has performed an important role in heating, ventilation, and air-conditioning systems for many years. raditionally, general ventilation air-filtration equipment has been used to protect cooling coils ...
De Mattia, Fabrizio; Chapsal, Jean-Michel; Descamps, Johan; Halder, Marlies; Jarrett, Nicholas; Kross, Imke; Mortiaux, Frederic; Ponsar, Cecile; Redhead, Keith; McKelvie, Jo; Hendriksen, Coenraad
2011-01-01
Current batch release testing of established vaccines emphasizes quality control of the final product and is often characterized by extensive use of animals. This report summarises the discussions of a joint ECVAM/EPAA workshop on the applicability of the consistency approach for routine release of human and veterinary vaccines and its potential to reduce animal use. The consistency approach is based upon thorough characterization of the vaccine during development and the principle that the quality of subsequent batches is the consequence of the strict application of a quality system and of a consistent production of batches. The concept of consistency of production is state-of-the-art for new-generation vaccines, where batch release is mainly based on non-animal methods. There is now the opportunity to introduce the approach into established vaccine production, where it has the potential to replace in vivo tests with non-animal tests designed to demonstrate batch quality while maintaining the highest quality standards. The report indicates how this approach may be further developed for application to established human and veterinary vaccines and emphasizes the continuing need for co-ordination and harmonization. It also gives recommendations for work to be undertaken in order to encourage acceptance and implementation of the consistency approach. Copyright © 2011. Published by Elsevier Ltd.. All rights reserved.
Lambert, Justin; Ghadry-Tavi, Rouzbeh; Knuff, Kate; Jutras, Marc; Siever, Jodi; Mick, Paul; Roque, Carolyn; Jones, Gareth; Little, Jonathan; Miller, Harry; Van Bergen, Colin; Kurtz, Donna; Murphy, Mary Ann; Jones, Charlotte Ann
2017-01-28
Hearing loss (HL) is a disability associated with poorer health-related quality of life including an increased risk for loneliness, isolation, functional fitness declines, falls, hospitalization and premature mortality. The purpose of this pilot trial is to determine the feasibility and acceptability of a novel intervention to reduce loneliness, improve functional fitness, social connectedness, hearing and health-related quality of life in older adults with HL. This 10-week, single-blind, pilot randomized control trial (RCT) will include a convenience sample of ambulatory adults aged 65 years or older with self-reported HL. Following baseline assessments, participants will be randomized to either intervention (exercise, health education, socialization and group auditory rehabilitation (GAR)) or control (GAR only) groups. The intervention group will attend a local YMCA twice a week and the control group once a week. Intervention sessions will include 45 min of strengthening, balance and resistance exercises, 30 min of group walking at a self-selected pace and 60 min of interactive health education or GAR. The control group will attend 60-min GAR sessions. GAR sessions will include education about hearing, hearing technologies, enhancing communication skills, and psychosocial support. Pre-post trial data collection and measures will include: functional fitness (gait speed, 30-s Sit to Stand Test), hearing and health-related quality of life, loneliness, depression, social participation and social support. At trial end, feasibility (recruitment, randomization, retention, acceptability) and GAR will be evaluated. Despite evidence suggesting that HL is associated with declines in functional fitness, there are no studies aimed at addressing functional fitness declines associated with the disability of HL. This pilot trial will provide knowledge about the physical, mental and social impacts on health related to HL as a disability. This will inform the feasibility of a larger RCT and preliminary evidence about the initial effects of a novel, community-based, holistic intervention addressing both the negative psychosocial and functional physical effects of HL among older adults. ClinicalTrials.gov, NCT02662192 . Registered on 14 January 2016.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamilton, D.R.; Evans, C.D.
The report discusses survey results on aspects of the quality assurance of radio-pharmaceuticals from 180 nuclear-medicine facilities in the United States. Data were collected from facilities in 8 states. Demographic information about nuclear-medicine operations and quality-assurance programs was gathered by state radiation-control-program personnel. The data collected from the survey show an incomplete acceptance of quality-assurance practices for radiopharmaceuticals. Most of the facilities in the survey indicated that, because an inferior radiopharmaceutical was prepared so infrequently, they did not believe it was cost-effective to perform extensive quality-assurance testing. The Center for Devices and Radiological Health hopes that the information from themore » survey will stimulate nuclear-medicine professionals and their organizations to encourage appropriate testing of all radiopharmaceuticals.« less
Nut-enriched bread is an effective and acceptable vehicle to improve regular nut consumption.
Devi, Asika; Chisholm, Alexandra; Gray, Andrew; Tey, Siew Ling; Williamson-Poutama, Destynee; Cameron, Sonya L; Brown, Rachel C
2016-10-01
Consuming 30 g of nuts/day is recommended to reduce chronic disease. However, nut consumption appears far from ideal among several populations. A potential strategy to increase consumption is to add nuts to a staple, for example, bread. Whether the health benefits and acceptability of nuts persist in this form is currently unknown. Thus, we examined the effects of consuming three nut-enriched breads on postprandial glycaemia, satiety, gastrointestinal tolerance, dietary intakes, and acceptance. In this controlled, crossover study, 32 participants were randomly allocated to receive one of four breads for 8 days each. Three breads contained either 30 g of finely sliced hazelnuts, 30 g semi-defatted hazelnut flour, or 15 g of each (amounts per 120 g bread) and were compared with a control nut-free bread. Blood glucose response was measured over 120 min, along with ratings of gastrointestinal discomfort. Appetite ratings and diet diaries were completed during each treatment period. Area under the blood glucose curve was significantly lower for the nut breads compared to the control bread (all P < 0.001), with no significant differences between the nut breads (all P ≥ 0.130). There were no significant differences in satiety (all P ≥ 0.135) or gastrointestinal symptoms (all P ≥ 0.102) between the breads. Acceptance was highest for the finely sliced hazelnut bread. Furthermore, consuming hazelnut-enriched bread improved diet quality, increasing monounsaturated fat, vitamin E, and dietary fibre intakes. Bread appears to be an effective and acceptable vehicle for increasing nut consumption, resulting in improved postprandial glycaemia and diet profiles. Long-term studies are now required.
Humidification and perceived indoor air quality in the office environment.
Reinikainen, L M; Aunela-Tapola, L; Jaakkola, J J
1997-01-01
OBJECTIVE: To evaluate the effect of humidification on the odour, acceptability, and stuffiness of indoor air. METHODS: In a six period cross over trial at the Pasila Office Center, Helsinki, the air of two wings of the building in turn were ventilated with air of 30%-40% humidity. A third wing served as a non-humidified control area. The quality of indoor air was assessed weekly by a panel containing 18 to 23 members. The intraindividual differences in the ratings for odour, stuffiness, and acceptability between humidified and non-humidified wings were used to assess the effect of humidification. The roles of sex, current smoking, and age as potential effect modifiers were assessed by comparing the mean intraindividual differences in ratings between the groups. RESULTS: Humidified air was found to be more odorous and stuffy (paired t test P = 0.0001) and less acceptable than the non-humidified air (McNemar's test P < 0.001). The differences in odour and stuffiness between humidified and non-humidified air were greater for women and for non-smokers, and greatest differences were in the youngest age group, and least in the oldest age group. The differences were not significant. CONCLUSIONS: An untrained panel of 20 members is able to differentiate a slight malodour and stuffiness in indoor air. The results suggest that steam air humidification decreases the perceived air quality. This effect is strongest in women and young subjects. PMID:9196454
Preparation before colonoscopy: a randomized controlled trial comparing different regimes.
Jansen, Sita V; Goedhard, Jelle G; Winkens, Bjorn; van Deursen, Cees Th B M
2011-10-01
A good bowel preparation is essential for optimal visualization of the large intestine. Several preparations with a difference in composition and volume are available. We compared five methods for bowel cleansing quality and patients' acceptability. Adult ambulatory outpatients scheduled for elective colonoscopy were randomized to receive 4-l polyethylene glycol (PEG) solution (Klean-prep), 2-l PEG solution+ascorbic acid (Moviprep), or a sodium phosphate (NaP) solution, Phosphoral. Patients with the PEG solutions were also randomized to receive simethicone (Aeropax), to investigate whether this improves the bowel cleansing efficacy. Before colonoscopy patients completed a questionnaire about the acceptability and tolerability of the preparation. Endoscopists blinded to the type of preparation gave a bowel cleansing score. Data were available for 461 patients. 2-l PEG+ascorbic acid was noninferior to 4-l PEG in bowel cleansing quality of rectosigmoid and colon. NaP was noninferior to 4-l PEG in bowel cleansing quality of rectosigmoid but inferior for the whole colon. Compliance was significantly less in the group with 4-l PEG compared with the 2-l PEG and NaP group. No difference was found for abdominal cramps. Taste was significantly better in the 2-l PEG group. Simethicone did not improve the bowel cleansing quality. 2-l PEG+ascorbic acid was noninferior to the 4-l PEG solution in bowel cleansing quality and was better in taste and compliance. NaP was inferior to 4-l PEG in bowel cleansing quality. Addition of simethicone gave no improvement.
2008-11-17
Accepted for oral presentation. o Bojesen SE, Malkki M, Gooley T, Zhao LP, Selvakumar A, Spellman S, Petersdorf E, Hansen JA and Dupont B. Genetic allelic...Oudshoorn M, Petersdorf E, Setterholm M, Champlin R and de Lima M. The clinical significance of matching for alleles at the low expression HLA loci...Reaction DMSO Dimethylsulphoxide PSA Public Service Announcement DNA Deoxyribonucleic Acid QC Quality control D/ R Donor/Recipient RCC Renal Cell
Parental financial incentives for increasing preschool vaccination uptake: systematic review.
Wigham, Sarah; Ternent, Laura; Bryant, Andrew; Robalino, Shannon; Sniehotta, Falko F; Adams, Jean
2014-10-01
Financial incentives have been used to promote vaccination uptake but are not always viewed as acceptable. Quasimandatory policies, such as requiring vaccinations for school enrollment, are widely implemented in some countries. A systematic review was conducted to determine the effectiveness, acceptability, and economic costs and consequences of parental financial incentives and quasimandatory schemes for increasing the uptake of preschool vaccinations in high-income countries. Electronic databases and gray literature were searched for randomized controlled trials, controlled before-and-after studies, and time series analyses examining the effectiveness of parental financial incentives and quasimandatory schemes, as well as any empirical studies exploring acceptability. All included studies were screened for information on economic costs and consequences. Two reviewers independently assessed studies for inclusion, extracted data, and assessed the quality of selected articles by using established instruments. Studies were synthesized in narrative reviews. Four studies on the effectiveness and 6 on the acceptability of parental financial incentives and quasimandatory interventions met the inclusion criteria. Only 1 study reported on costs and consequences. Studies of effectiveness had low risk of bias but displayed substantial heterogeneity in terms of interventions and methods. There was insufficient evidence to conclude whether these interventions were effective. Studies of acceptability suggested a preference, in settings where this already occurs, for incentives linking vaccinations to access to education. There was insufficient evidence to draw conclusions on economic costs and consequences. Copyright © 2014 by the American Academy of Pediatrics.
Chang, Hyein; Shaw, Daniel S; Shelleby, Elizabeth C; Dishion, Thomas J; Wilson, Melvin N
2017-05-01
We examined the longitudinal effects of the Family Check-Up (FCU) intervention beginning in toddlerhood on children's peer preference at school-age. Specifically, a sequential mediational model was proposed in which the FCU was hypothesized to promote peer preference (i.e., higher acceptance and lower rejection by peers) in middle childhood through its positive effects on parent-child interaction and child effortful control in early childhood. Participants were 731 low-income families (49 % female). Qualities of parent-child interaction were observed during structured activities at 2 to 5 years, child effortful control was assessed using behavioral tasks at 5 years, and peer acceptance and rejection were rated by teachers at 7.5 to 10.5 years. Results indicated that the FCU indirectly predicted peer preference by sequentially improving parent-child interaction and child effortful control. The findings are discussed with respect to implications for understanding mechanisms by which early parenting-focused programs may enhance child functioning across time and context.
Shaw, Daniel S.; Shelleby, Elizabeth C.; Dishion, Thomas J.; Wilson, Melvin N.
2018-01-01
We examined the longitudinal effects of the Family Check-Up (FCU) intervention beginning in toddlerhood on children’s peer preference at school-age. Specifically, a sequential mediational model was proposed in which the FCU was hypothesized to promote peer preference (i.e., higher acceptance and lower rejection by peers) in middle childhood through its positive effects on parent-child interaction and child effortful control in early childhood. Participants were 731 low-income families (49 % female). Qualities of parent-child interaction were observed during structured activities at 2 to 5 years, child effortful control was assessed using behavioral tasks at 5 years, and peer acceptance and rejection were rated by teachers at 7.5 to 10.5 years. Results indicated that the FCU indirectly predicted peer preference by sequentially improving parent-child interaction and child effortful control. The findings are discussed with respect to implications for understanding mechanisms by which early parenting-focused programs may enhance child functioning across time and context. PMID:27558394
Age and Acceptance of Euthanasia.
ERIC Educational Resources Information Center
Ward, Russell A.
1980-01-01
Study explores relationship between age (and sex and race) and acceptance of euthanasia. Women and non-Whites were less accepting because of religiosity. Among older people less acceptance was attributable to their lesser education and greater religiosity. Results suggest that quality of life in old age affects acceptability of euthanasia. (Author)
Diez-Sánchez, Elena; Llorca, Empar; Quiles, Amparo; Hernando, Isabel
2018-01-01
This study assessed the effect of substituting 30% of fat by soluble, insoluble fiber, or a mix of both fibers in sponge cake quality, structure, acceptability, and starch digestibility. The apparent viscosity of the different formulations was measured and micro-baking was simulated. Texture profile tests were carried out and the crumb structure was examined. In vitro digestion was performed to study the digestibility of starch and a sensory test was carried out to know consumer acceptance. The soluble fiber (maltodextrin) affected the structure and quality of the cakes less than the insoluble fiber (potato fiber) and the use of soluble fiber in the formulation resulted in lower glucose release under in vitro conditions. Moreover, the consumer did not find differences among the control cake and the cakes prepared with soluble fiber. Considering the results as a whole, soluble fiber may be used for partial replacement of fat in sponge cake formulations and may constitute an appropriate strategy for obtaining healthy sponge cakes.
Fregonesi, R P; Portes, R G; Aguiar, A M M; Figueira, L C; Gonçalves, C B; Arthur, V; Lima, C G; Fernandes, A M; Trindade, M A
2014-06-01
Reducing spoilage and indicator bacteria is important for microbiological stability in meat and meat products. The objective was to evaluate the effect of different doses of gamma radiation on the shelf-life of lamb meat, vacuum-packed and stored under refrigeration, by assessing the microbiological safety, physicochemical stability and sensory quality. Lamb loin cuts (Longissimus dorsi) were irradiated with 1.5kGy and 3.0kGy. The samples, including control, were stored at 1±1°C during 56days. Samples were analyzed on zero, 14, 28, 42 and 56days by their microbiological and physicochemical characteristics. Sensory quality was carried out on day zero. The results showed a reduction (p<0.05) in the microbial load of the irradiated samples. The acceptance of lamb loins was not affected (p>0.05) by the radiation doses. Thus gamma irradiation at 3.0kGy was effective in reducing the content of microorganisms, without harming the physicochemical characteristics evaluated. Copyright © 2014 Elsevier Ltd. All rights reserved.
[Development of products for the elderly population: vitamin enriched pudding].
Vera, M S; de Penna, E W; Bunger, A; Soto, D; Cariaga, L; Fuenzalida, R; Cornejo, E; Lopez, L
1995-03-01
An instant dessert powder, pudding type was developed to be consumed at lunch or dinner time. The dessert was designed to be prepared in skim milk and meets the nutritional needs of elderly people. The dessert contains modified starch, carragenine, vegetal fat, sacharose. Each serving has been enriched with 30% of the daily vitamin requirement advised for adults over 51 years old. The optimized process was carried out according to the Karlsruhe test. Each serving consists of 22g powder prepared in proportion of 18% in skim milk. The optimized dessert powder was controlled by means of physical, chemical and microbiological analyses. The sensory quality was determined in the ready to eat product and the acceptability level was measured in a group of people selected according to the characteristics of the target population. The dessert powder contains 1.1% protein, 5.2% fats, 89.76% carbohidrates, and provides 409 Kcal/100g. Both the sensory and microbiological quality were good and the level of acceptance reached 98%.
Moore, Craig S; Horsfield, Carl J; Saunderson, John R; Beavis, Andrew W
2015-01-01
Objective: The purpose of this study was to develop size-based radiotherapy kilovoltage cone beam CT (CBCT) protocols for the pelvis. Methods: Image noise was measured in an elliptical phantom of varying size for a range of exposure factors. Based on a previously defined “small pelvis” reference patient and CBCT protocol, appropriate exposure factors for small, medium, large and extra-large patients were derived which approximate the image noise behaviour observed on a Philips CT scanner (Philips Medical Systems, Best, Netherlands) with automatic exposure control (AEC). Selection criteria, based on maximum tube current–time product per rotation selected during the radiotherapy treatment planning scan, were derived based on an audit of patient size. Results: It has been demonstrated that 110 kVp yields acceptable image noise for reduced patient dose in pelvic CBCT scans of small, medium and large patients, when compared with manufacturer's default settings (125 kVp). Conversely, extra-large patients require increased exposure factors to give acceptable images. 57% of patients in the local population now receive much lower radiation doses, whereas 13% require higher doses (but now yield acceptable images). Conclusion: The implementation of size-based exposure protocols has significantly reduced radiation dose to the majority of patients with no negative impact on image quality. Increased doses are required on the largest patients to give adequate image quality. Advances in knowledge: The development of size-based CBCT protocols that use the planning CT scan (with AEC) to determine which protocol is appropriate ensures adequate image quality whilst minimizing patient radiation dose. PMID:26419892
Kiropoulos, Litza A; Kilpatrick, Trevor; Holmes, Alex; Threader, Jennifer
2016-12-07
To examine the effectiveness and acceptability of an 8-week individual tailored cognitive behavioural therapy (CBT) intervention for the treatment of depressive symptoms in those newly diagnosed with multiple sclerosis. The current study presents a pilot, parallel group randomized controlled trial (RCT) with an allocation ratio of 1:1 conducted in a large research and teaching hospital in Melbourne, Australia. 30 individuals with a mean age of 36.93 years (SD = 9.63) who were newly diagnosed with multiple sclerosis (MS) (X = 24.87 months, SD = 15.61) were randomized to the CBT intervention (n = 15) or treatment as usual (TAU) (n = 15). The primary outcome was level of depressive symptoms using the Beck Depression Inventory-II (BDI-II). Secondary outcomes were level of anxiety, fatigue and pain impact, sleep quality, coping, acceptance of MS illness, MS related quality of life, social support, and resilience. Tertiary outcomes were acceptability and adherence to the intervention. Large between group treatment effects were found for level of depressive symptoms at post and at 20 weeks follow-up (d = 1.66-1.34). There were also small to large group treatment effects for level of anxiety, fatigue and pain impact, sleep quality, MS related quality of life, resilience, and social support at post and at 20 weeks follow-up (d = 0.17-1.63). There were no drop-outs and participants completed all treatment modules. All participants reported the treatment as 'very useful', and most (73.4%) reported that the intervention had addressed their problems 'completely'. These data suggest that the tailored early intervention is appropriate and clinically effective for the treatment of depressive symptoms in those newly diagnosed with MS. A larger RCT comparing the CBT intervention with an active comparative treatment with longer term follow-up and cost effectiveness analyses is warranted. The pilot trial has been retrospectively registered on 28/04/2016 with the ISRCTN registry (trial ID ISRCTN10423371).
A multiple objective optimization approach to quality control
NASA Technical Reports Server (NTRS)
Seaman, Christopher Michael
1991-01-01
The use of product quality as the performance criteria for manufacturing system control is explored. The goal in manufacturing, for economic reasons, is to optimize product quality. The problem is that since quality is a rather nebulous product characteristic, there is seldom an analytic function that can be used as a measure. Therefore standard control approaches, such as optimal control, cannot readily be applied. A second problem with optimizing product quality is that it is typically measured along many dimensions: there are many apsects of quality which must be optimized simultaneously. Very often these different aspects are incommensurate and competing. The concept of optimality must now include accepting tradeoffs among the different quality characteristics. These problems are addressed using multiple objective optimization. It is shown that the quality control problem can be defined as a multiple objective optimization problem. A controller structure is defined using this as the basis. Then, an algorithm is presented which can be used by an operator to interactively find the best operating point. Essentially, the algorithm uses process data to provide the operator with two pieces of information: (1) if it is possible to simultaneously improve all quality criteria, then determine what changes to the process input or controller parameters should be made to do this; and (2) if it is not possible to improve all criteria, and the current operating point is not a desirable one, select a criteria in which a tradeoff should be made, and make input changes to improve all other criteria. The process is not operating at an optimal point in any sense if no tradeoff has to be made to move to a new operating point. This algorithm ensures that operating points are optimal in some sense and provides the operator with information about tradeoffs when seeking the best operating point. The multiobjective algorithm was implemented in two different injection molding scenarios: tuning of process controllers to meet specified performance objectives and tuning of process inputs to meet specified quality objectives. Five case studies are presented.
Implementation of Quality Management in Core Service Laboratories
Creavalle, T.; Haque, K.; Raley, C.; Subleski, M.; Smith, M.W.; Hicks, B.
2010-01-01
CF-28 The Genetics and Genomics group of the Advanced Technology Program of SAIC-Frederick exists to bring innovative genomic expertise, tools and analysis to NCI and the scientific community. The Sequencing Facility (SF) provides next generation short read (Illumina) sequencing capacity to investigators using a streamlined production approach. The Laboratory of Molecular Technology (LMT) offers a wide range of genomics core services including microarray expression analysis, miRNA analysis, array comparative genome hybridization, long read (Roche) next generation sequencing, quantitative real time PCR, transgenic genotyping, Sanger sequencing, and clinical mutation detection services to investigators from across the NIH. As the technology supporting this genomic research becomes more complex, the need for basic quality processes within all aspects of the core service groups becomes critical. The Quality Management group works alongside members of these labs to establish or improve processes supporting operations control (equipment, reagent and materials management), process improvement (reengineering/optimization, automation, acceptance criteria for new technologies and tech transfer), and quality assurance and customer support (controlled documentation/SOPs, training, service deficiencies and continual improvement efforts). Implementation and expansion of quality programs within unregulated environments demonstrates SAIC-Frederick's dedication to providing the highest quality products and services to the NIH community.
23 CFR 637.207 - Quality assurance program.
Code of Federal Regulations, 2012 CFR
2012-04-01
... program. (a) Each STD's quality assurance program shall provide for an acceptance program and an independent assurance (IA) program consisting of the following: (1) Acceptance program. (i) Each STD's... STD shall establish a dispute resolution system. The dispute resolution system shall address the...
23 CFR 637.207 - Quality assurance program.
Code of Federal Regulations, 2014 CFR
2014-04-01
... program. (a) Each STD's quality assurance program shall provide for an acceptance program and an independent assurance (IA) program consisting of the following: (1) Acceptance program. (i) Each STD's... STD shall establish a dispute resolution system. The dispute resolution system shall address the...
23 CFR 637.207 - Quality assurance program.
Code of Federal Regulations, 2013 CFR
2013-04-01
... program. (a) Each STD's quality assurance program shall provide for an acceptance program and an independent assurance (IA) program consisting of the following: (1) Acceptance program. (i) Each STD's... STD shall establish a dispute resolution system. The dispute resolution system shall address the...
48 CFR 2446.502 - Responsibility for acceptance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Responsibility for acceptance. 2446.502 Section 2446.502 Federal Acquisition Regulations System DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT CONTRACT MANAGEMENT QUALITY ASSURANCE Acceptance 2446.502 Responsibility for acceptance. ...
Polymerase Chain Reaction/Rapid Methods Are Gaining a Foothold in Developing Countries.
Ragheb, Suzan Mohammed; Jimenez, Luis
Detection of microbial contamination in pharmaceutical raw materials and finished products is a critical factor to guarantee their safety, stability, and potency. Rapid microbiological methods-such as polymerase chain reaction-have been widely applied to clinical and food quality control analysis. However, polymerase chain reaction applications to pharmaceutical quality control have been rather slow and sporadic. Successful implementation of these methods in pharmaceutical companies in developing countries requires important considerations to provide sensitive and robust assays that will comply with good manufacturing practices. In recent years several publications have encouraged the application of molecular techniques in the microbiological assessment of pharmaceuticals. One of these techniques is polymerase chain reaction (PCR). The successful application of PCR in the pharmaceutical industry in developing countries is governed by considerable factors and requirements. These factors include the setting up of a PCR laboratory and the choice of appropriate equipment and reagents. In addition, the presence of well-trained analysts and establishment of quality control and quality assurance programs are important requirements. The pharmaceutical firms should take into account these factors to allow better chances for regulatory acceptance and wide application of this technique. © PDA, Inc. 2014.
Jalali, Nastaran; Ariiai, Peiman; Fattahi, Esmaeil
2016-01-01
The effects of alginate/carboxyl methylcellulose composite coating incorporated with clove essential oil on quality of silver carp fillet chilled storage (4 + 1 °C) were examined over a period of 16 days. The control samples (c), alginate/carboxyl methylcellulose coating (C-A), alginate/carboxyl methylcellulose composite coating incorporated with clove essential oil (with different concentration 1 and 1.5 %) (C-A + CEO1 % and C-A + CEO 15 % respectively) were analyzed by bacteriological (total viable counts (TVC) and total psychrotrophic counts (TPC)), biochemical (Peroxide value (PV), free fatty acid (FFA), total volatile base nitrogen (TVB-N), and pH) and sensory characteristics. Also, the efficacy of these treatments was investigated in control of the population of Eschershia coli O157:H7 inoculated in silver carp fillet. According to the obtained results, C-A + CEO 1.5 % showed lowest (p < 0.05) and acceptable biochemical, bacteriological and sensory characteristics attributes up to 16 days storage at 4 °C compared to the others. Also, this treated sample was acceptable even at the end of the 16-day storage and it could reduce the population of E. coli O157:H7 below the acceptable level (<2) from day 4 until the end of the storage period. The results indicate Alginate/carboxyl methylcellulose composite coating with clove essential oil might be recommended as a preservative in the meat products.
Spirometry in 3-5-year-old children with asthma.
Nève, Véronique; Edmé, Jean-Louis; Devos, Patrick; Deschildre, Antoine; Thumerelle, Caroline; Santos, Clarisse; Methlin, Catherine-Marie; Matran, Murielle; Matran, Régis
2006-08-01
Spirometry with incentive games was applied to 207 2-5-year-old preschool children (PSC) with asthma in order to refine the quality-control criteria proposed by Aurora et al. (Am J Respir Crit Care Med 2004;169:1152-159). The data set in our study was much larger compared to that in Aurora et al. (Am J Respir Crit Care Med 2004;169:1152-159), where 42 children with cystic fibrosis and 37 healthy control were studied. At least two acceptable maneuvers were obtained in 178 (86%) children. Data were focused on 3-5-year-old children (n = 171). The proportion of children achieving a larger number of thresholds for each quality-control criterion (backward-extrapolated volume (Vbe), Vbe in percent of forced vital capacity (FVC, Vbe/FVC), time-to-peak expiratory flow (time-to-PEF), and difference (Delta) between the two FVCs (DeltaFVC), forced expiratory volume in 1 sec (DeltaFEV(1)), and forced expiratory volume in 0.5 sec (DeltaFEV(0.5)) from the two "best" curves) was calculated, and cumulative plots were obtained. The optimal threshold was determined for all ages by derivative function of rate of success-threshold curves, close to the inflexion point. The following thresholds were defined for acceptability: Vbe
Improving Quality of Care in Primary Health-Care Facilities in Rural Nigeria
Ugo, Okoli; Ezinne, Eze-Ajoku; Modupe, Oludipe; Nicole, Spieker; Kelechi, Ohiri
2016-01-01
Background: Nigeria has a high population density but a weak health-care system. To improve the quality of care, 3 organizations carried out a quality improvement pilot intervention at the primary health-care level in selected rural areas. Objective: To assess the change in quality of care in primary health-care facilities in rural Nigeria following the provision of technical governance support and to document the successes and challenges encountered. Method: A total of 6 states were selected across the 6 geopolitical zones of the country. However, assessments were carried out in 40 facilities in only 5 states. Selection was based on location, coverage, and minimum services offered. The facilities were divided randomly into 2 groups. The treatment group received quality-of-care assessment, continuous feedback, and improvement support, whereas the control group received quality assessment and no other support. Data were collected using the SafeCare Healthcare Standards and managed on the SafeCare Data Management System—AfriDB. Eight core areas were assessed at baseline and end line, and compliance to quality health-care standards was compared. Result: Outcomes from 40 facilities were accepted and analyzed. Overall scores increased in the treatment facilities compared to the control facilities, with strong evidence of improvement (t = 5.28, P = .0004) and 11% average improvement, but no clear pattern of improvement emerged in the control group. Conclusion: The study demonstrated governance support and active community involvement offered potential for quality improvement in primary health-care facilities. PMID:28462280
Ugo, Okoli; Ezinne, Eze-Ajoku; Modupe, Oludipe; Nicole, Spieker; Winifred, Ekezie; Kelechi, Ohiri
2016-01-01
Nigeria has a high population density but a weak health-care system. To improve the quality of care, 3 organizations carried out a quality improvement pilot intervention at the primary health-care level in selected rural areas. To assess the change in quality of care in primary health-care facilities in rural Nigeria following the provision of technical governance support and to document the successes and challenges encountered. A total of 6 states were selected across the 6 geopolitical zones of the country. However, assessments were carried out in 40 facilities in only 5 states. Selection was based on location, coverage, and minimum services offered. The facilities were divided randomly into 2 groups. The treatment group received quality-of-care assessment, continuous feedback, and improvement support, whereas the control group received quality assessment and no other support. Data were collected using the SafeCare Healthcare Standards and managed on the SafeCare Data Management System-AfriDB. Eight core areas were assessed at baseline and end line, and compliance to quality health-care standards was compared. Outcomes from 40 facilities were accepted and analyzed. Overall scores increased in the treatment facilities compared to the control facilities, with strong evidence of improvement ( t = 5.28, P = .0004) and 11% average improvement, but no clear pattern of improvement emerged in the control group. The study demonstrated governance support and active community involvement offered potential for quality improvement in primary health-care facilities.
Aboshora, Waleed; Lianfu, Zhang; Dahir, Mohammed; Qingran, Meng; Musa, Abubakr; Gasmalla, Mohammed A A; Omar, Khamis Ali
2016-01-01
In this covenant of functional foods, the world seeks for new healthier food products with appropriate proportions of bioactive constituents such as fiber, mineral elements, phenols and flavonoids. The doum fruit has good nutritional and pharmaceutical properties; therefore, its incorporation in breads could be beneficial in improving human health. In the current study, partial substitution of wheat flour (WF) with doum fruit flour (DFF) at levels of 5 %, 10 %, 15 % and 20 % were carried out to investigate the dough viscoelastic properties, baking performance, proximate compositions and antioxidant properties of the breads. Partial substitution of WF with DFF increased the water absorption and developing time of dough (P ≤ 0.05), while, the dough extensibility, resistance to extension and the deformation energy were reduced. Bread supplemented with DFF resulted in a reduction in quality in terms of specific loaf volume, conferred softness, hardness, cohesiveness and gumminess to the bread crumbs. DFF up to 15 % could partially replace WF in bread; increase its nutritional value in terms of fiber content and minerals, with only a small depreciation in the bread quality. Sensory evaluation showed that breads supplemented up to 15 % DFF were acceptable to the panelists and there was no significant difference in terms of taste, texture and overall acceptability compared to the control. The incorporation of DFF increased the total phenolic contents, total flavonoids contents and antioxidant properties compared to the control (for both flour and bread).
Hernández, Maciel M.; Eisenberg, Nancy; Valiente, Carlos; Diaz, Anjolii; VanSchyndel, Sarah K.; Berger, Rebecca H.; Terrell, Nathan; Silva, Kassondra M.; Spinrad, Tracy L.; Southworth, Jody
2015-01-01
The purpose of the study was to evaluate bidirectional associations between peer acceptance and both emotion and effortful control during kindergarten (N = 301). In both the fall and spring semesters, we obtained peer nominations of acceptance, measures of positive and negative emotion based on naturalistic observations in school (i.e., classroom, lunch/recess), and observers’ reports of effortful control (i.e., inhibitory control, attention focusing) and emotions (i.e., positive, negative). In structural equation panel models, peer acceptance in fall predicted higher effortful control in spring. Effortful control in fall did not predict peer acceptance in spring. Negative emotion predicted lower peer acceptance across time for girls but not for boys. Peer acceptance did not predict negative or positive emotion over time. In addition, we tested interactions between positive or negative emotion and effortful control predicting peer acceptance. Positive emotion predicted higher peer acceptance for children low in effortful control. PMID:28348445
Mindfulness-Based Intervention for Adolescents with Recurrent Headaches: A Pilot Feasibility Study
Hesse, Toni; Holmes, Laura G.; Kennedy-Overfelt, Vicki; Kerr, Lynne M.; Giles, Lisa L.
2015-01-01
Recurrent headaches cause significant burden for adolescents and their families. Mindfulness-based interventions (MBIs) have been shown to reduce stress and alter the experience of pain, reduce pain burden, and improve quality of life. Research indicates that MBIs can benefit adults with chronic pain conditions including headaches. A pilot nonrandomized clinical trial was conducted with 20 adolescent females with recurrent headaches. Median class attendance was 7 of 8 total sessions; average class attendance was 6.10 ± 2.6. Adherence to home practice was good, with participants reporting an average of 4.69 (SD = 1.84) of 6 practices per week. Five participants dropped out for reasons not inherent to the group (e.g., extracurricular scheduling); no adverse events were reported. Parents reported improved quality of life and physical functioning for their child. Adolescent participants reported improved depression symptoms and improved ability to accept their pain rather than trying to control it. MBIs appear safe and feasible for adolescents with recurrent headaches. Although participants did not report decreased frequency or severity of headache following treatment, the treatment had a beneficial effect for depression, quality of life, and acceptance of pain and represents a promising adjunct treatment for adolescents with recurrent headaches. PMID:26798398
Proximal Humerus Fractures: Evaluation and Management in the Elderly Patient
Grawe, Brian
2018-01-01
Introduction: Proximal humerus fractures are common in the elderly. The evaluation and management of these injuries is often controversial. The purpose of this study is to review recent evidence and provide updated recommendations for treating proximal humerus fractures in the elderly. Methods: A literature review of peer-reviewed publications related to the evaluation and management of proximal humerus fractures in the elderly was performed. There was a focus on randomized controlled trials and systematic reviews published within the last 5 years. Results: The incidence of proximal humerus fractures is increasing. It is a common osteoporotic fracture. Bone density is a predictor of reduction quality and can be readily assessed with anteroposterior views of the shoulder. Social independence is a predictor of outcome, whereas age is not. Many fractures are minimally displaced and respond acceptably to nonoperative management. Displaced and severe fractures are most frequently treated operatively with intramedullary nails, locking plates, percutaneous techniques, or arthroplasty. Discussion: Evidence from randomized controlled trials and systematic reviews is insufficient to recommend a treatment; however, most techniques have acceptable or good outcomes. Evaluation should include an assessment of the patient’s bone quality, social independence, and surgical risk factors. With internal fixation, special attention should be paid to medial comminution, varus angulation, and restoration of the calcar. With arthroplasty, attention should be paid to anatomic restoration of the tuberosities and proper placement of the prosthesis. Conclusion: A majority of minimally displaced fractures can be treated conservatively with early physical therapy. Treatment for displaced fractures should consider the patient’s level of independence, bone quality, and surgical risk factors. Fixation with percutaneous techniques, intramedullary nails, locking plates, and arthroplasty are all acceptable treatment options. There is no clear evidence-based treatment of choice, and the surgeon should consider their comfort level with various procedures during the decision-making process. PMID:29399372
NASA Astrophysics Data System (ADS)
Zäh, Ralf-Kilian; Mosbach, Benedikt; Hollwich, Jan; Faupel, Benedikt
2017-02-01
To ensure the competitiveness of manufacturing companies it is indispensable to optimize their manufacturing processes. Slight variations of process parameters and machine settings have only marginally effects on the product quality. Therefore, the largest possible editing window is required. Such parameters are, for example, the movement of the laser beam across the component for the laser keyhole welding. That`s why it is necessary to keep the formation of welding seams within specified limits. Therefore, the quality of laser welding processes is ensured, by using post-process methods, like ultrasonic inspection, or special in-process methods. These in-process systems only achieve a simple evaluation which shows whether the weld seam is acceptable or not. Furthermore, in-process systems use no feedback for changing the control variables such as speed of the laser or adjustment of laser power. In this paper the research group presents current results of the research field of Online Monitoring, Online Controlling and Model predictive controlling in laser welding processes to increase the product quality. To record the characteristics of the welding process, tested online methods are used during the process. Based on the measurement data, a state space model is ascertained, which includes all the control variables of the system. Depending on simulation tools the model predictive controller (MPC) is designed for the model and integrated into an NI-Real-Time-System.
Kaur, Sukhpreet; Aggarwal, Poonam
2016-04-01
The present study was carried out to develop waris from potato and legume blends and to analyze them for organoleptic, physicochemical, phytochemical and shelf life quality. Wari is a partially fermented legume based savoury, used as adjunct in vegetable curries. In this study, potato (boiled and dehydrated) was used to supplement black gram or urad dhal waris. Two processing cultivars (Kufri Chipsona-1, Kufri Chandramukhi) and one commonly grown cultivar (Kufri Pukhraj) were evaluated for processing into waris. Based on preliminary sensory trails, waris with potato (70 %) and urad dhal (30 %) level of supplementation were found to be most acceptable and these waris were subjected to nutritional evaluation. Storage stability of the waris was assessed by storing the product at room temperature for a period of 12 months. Results were compared with dhal waris (control). Protein content was significantly higher in control waris compared to potato supplemented waris. Bioactive compounds including ascorbic acid, total phenolics and total antioxidant activity measured as DPPH radical scavenging activity increased significantly on incorporation of potato. Between the cultivars, waris enriched with Kufri Pukhraj, a table variety which is considered unfit for processing, displayed the highest phytochemical content and total antioxidant activity. Sensory evaluation indicated higher overall acceptability scores of potato enriched waris compared to control waris. Between the treatments i.e. boiled mash and dehydrated flour, waris supplemented with boiled potato mash showed a significantly higher content of phytochemicals and total antioxidant activity compared to potato flour waris. However no significant difference was observed in sensory quality of the product prepared either with fresh potato mash or potato flour. Storage studies showed that the potato waris can be stored safely for 12 months with its nutrient constituents intact.
Dorrington, Melanie S; Herceg, Ana; Douglas, Kirsty; Tongs, Julie; Bookallil, Marianne
2015-01-01
This article describes translational research (TR) and continuous quality improvement (CQI) processes used to identify and address barriers and facilitators to Pap smear screening within an urban Aboriginal Community Controlled Health Service (ACCHS). Rapid Plan-Do-Study-Act (PDSA) cycles were conducted, informed by client surveys, a data collection tool, focus groups and internal research. There was a statistically significant increase in Pap smear numbers during PDSA cycles, continuing at 10 months follow up. The use of TR with CQI appears to be an effective and acceptable way to affect Pap smear screening. Community and service collaboration should be at the core of research in Aboriginal and Torres Strait Islander health settings. This model is transferrable to other settings and other health issues.
Choi, Yun-Sang; Kim, Hyun-Wook; Hwang, Ko-Eun; Song, Dong-Heon; Jeong, Tae-Jeon; Kim, Young-Boong; Jeon, Ki-Hong; Kim, Cheon-Jei
2015-01-01
In this study, we evaluated the effects of dietary fiber extracted from Algelica keiskei Koidz on the chemical composition, cooking characteristics, and sensory properties of chicken patties. The chicken patties with Algelica keiskei Koidz dietary fiber had significantly higher moisture and ash content, and yellowness than the control sample (p<0.05). Energy value, cooking loss, reduction in diameter, reduction in thickness, lightness, redness, hardness, cohesiveness, gumminess, and chewiness of the control samples was significantly higher than chicken patties with Algelica keiskei Koidz dietary fiber (p<0.05). The sensory evaluation indicated that the greatest overall acceptability in chicken patties was achieved at Algelica keiskei Koidz dietary fiber levels of 1% and 2%. Chicken patties supplemented with 2% Algelica keiskei Koidz dietary fiber had improved quality characteristics.
A first-line nurse manager's goal-profile.
Johansson, Gunilla; Pörn, Ingmar; Theorell, Töres; Gustafsson, Barbro
2007-01-01
The aim of this case study was to acquire understanding concerning the first-line nurse manager's goal-profile, i.e. prioritization of goals in her work as a first-line nurse manager, through use of an action-theoretic and confirmatory theory. The first-line nurse manager's pivotal role regarding quality of care and development in relation to on-going changes in the health care sector is stressed by many researchers and the transition from nurse to manager is described as a demanding challenge for the first-line nurse manager. The case study described in this paper concerns a first-line nurse manager in an actual working environment in care of older people. Data collection comprised interviews, observations, a job description and policy documents. A hermeneutic interpretation was used for data analysis. The results showed that the first-line nurse manager had three goals in her goal-profile, in the following order of priority: (i) a nurse goal that she had strongly accepted and in which she had excellent control, (ii) an administrator goal that she had accepted and in which she had control, (iii) a leadership goal that she had not accepted and in which she did not have control. Both the administrator and leadership goals were based on her job description, but the nurse goal was a personally chosen goal based on her own self-relation/goal-fulfillment. The first-line nurse manager's prioritized self-identity, based on successful realization of goals in her goal-profile, was decisive in the manifestation of her work. This study contributes to a new understanding of the first-line nurse manager's self-identity related to work in terms of goal acceptance and goal control of prioritized goals. This action-theoretic approach could be a valuable 'key' for understanding leadership (or lack of leadership) in clinical practice.
ERIC Educational Resources Information Center
Žibeniene, Gintaute; Savickiene, Izabela
2014-01-01
The article presents which conceptions of higher education quality are most acceptable to first-year students of the study field of pedagogy. It is significant to analyse students' opinions as more than 10 years ago the EU member states agreed that higher education institutions bear responsibility for the quality of higher education. Being members…
de Kinderen, Reina J A; Lambrechts, Danielle A J E; Wijnen, Ben F M; Postulart, Debby; Aldenkamp, Albert P; Majoie, Marian H J M; Evers, Silvia M A A
2016-01-01
To gain insight into the cost-effectiveness of the ketogenic (KD) diet compared with care as usual (CAU) in children and adolescents with intractable epilepsy, we conducted an economic evaluation from a societal perspective, alongside a randomized controlled trial. Participants from a tertiary epilepsy center were randomized into KD (intervention) group or CAU (control) group. Seizure frequency, quality adjusted life years (QALYs), health care costs, production losses of parents and patient, and family costs were assessed at baseline and during a 4-month study period and compared between the intervention and control groups. The incremental cost-effectiveness ratios (ICERs) (i.e., cost per QALY and cost per responder), and cost-effectiveness acceptability curves (CEACs) were calculated and presented. In total, 48 children were included in the analyses of this study (26 KD group). At 4 months, 50% of the participants in the KD group had a seizure reduction ≥50% from baseline, compared with 18.2 of the participants in the CAU group. The mean costs per patient in the CAU group were €15,245 compared to €20,986 per patient in the KD group, resulting in an ICER of €18,044 per responder. We failed, however, to measure any benefits in terms of QALYs and therefore, the cost per QALY rise high above any acceptable ceiling ratio. It might be that the quality of life instruments used in this study were not sufficiently sensitive to detect changes, or it might be that being a clinical responder is not sufficient to improve a patient's quality of life. Univariate and multivariate sensitivity analyses and nonparametric bootstrapping were performed and demonstrated the robustness of our results. The results show that the KD reduces seizure frequency. The study did not find any improvements in quality of life and, therefore, unfavorable cost per QALY ratio's resulted. Wiley Periodicals, Inc. © 2015 International League Against Epilepsy.
Morey, Amit; Bowers, Jordan W J; Bauermeister, Laura J; Singh, Manpreet; Huang, Tung-Shi; McKee, Shelly R
2014-01-01
The objective of this study was to evaluate anti-listerial efficacy of salts of organic acids, and their impact on the quality of frankfurters. Beef frankfurters were manufactured by incorporating organic acids in 5 different combinations: (1) control (no marinade addition; C); (2) sodium lactate (2% wt/wt; SL); (3) potassium lactate (2% wt/wt; PL); (4) sodium citrate (0.75% wt/wt; SC); and (5) sodium lactate (2% wt/wt)/sodium diacetate (0.25% wt/wt; SL/SD). Cooked frankfurters were inoculated with streptomycin-resistant (1500 μg/mL) L. monocytogenes (7 log₁₀ CFU/frank). Inoculated and noninoculated frankfurters were vacuum packaged and stored at 4 °C. Samples were taken weekly up to 10 wk for estimation of L. monocytogenes as well as aerobic plate count (APC) and psychrotrophs (PSY), respectively. Total of 2 independent trials of the entire experiment were conducted. Noninoculated beef frankfurters were evaluated weekly by untrained sensory panelists for 7 wk. SL, PL, and SC treatments did not (P > 0.05) adversely affect consumer acceptability through 8 wk although, SL/SD treatment was significantly (P ≤ 0.05) less preferred across all sensory attributes. SL/SD treatment negatively affected product quality, but was able to control APC, PSY, and L. monocytogenes levels. SC performed similar to the control throughout the 8, 9, and 10 wk storage periods, providing no benefit for inhibiting L. monocytogenes (increasing from 7 logs CFU/frank to 10 logs CFU/frank throughout storage) or extending shelf life of the beef frankfurters. In conclusion, 2% SL and PL, and 2% SL/0.25% SD may be effective L. monocytogenes inhibitors (maintaining inoculation levels of 7 logs CFU/frank during storage), but changes in SL/SD treatment formulation should be studied to improve product quality. © 2013 Institute of Food Technologists®
Automatic quality control in clinical (1)H MRSI of brain cancer.
Pedrosa de Barros, Nuno; McKinley, Richard; Knecht, Urspeter; Wiest, Roland; Slotboom, Johannes
2016-05-01
MRSI grids frequently show spectra with poor quality, mainly because of the high sensitivity of MRS to field inhomogeneities. These poor quality spectra are prone to quantification and/or interpretation errors that can have a significant impact on the clinical use of spectroscopic data. Therefore, quality control of the spectra should always precede their clinical use. When performed manually, quality assessment of MRSI spectra is not only a tedious and time-consuming task, but is also affected by human subjectivity. Consequently, automatic, fast and reliable methods for spectral quality assessment are of utmost interest. In this article, we present a new random forest-based method for automatic quality assessment of (1)H MRSI brain spectra, which uses a new set of MRS signal features. The random forest classifier was trained on spectra from 40 MRSI grids that were classified as acceptable or non-acceptable by two expert spectroscopists. To account for the effects of intra-rater reliability, each spectrum was rated for quality three times by each rater. The automatic method classified these spectra with an area under the curve (AUC) of 0.976. Furthermore, in the subset of spectra containing only the cases that were classified every time in the same way by the spectroscopists, an AUC of 0.998 was obtained. Feature importance for the classification was also evaluated. Frequency domain skewness and kurtosis, as well as time domain signal-to-noise ratios (SNRs) in the ranges 50-75 ms and 75-100 ms, were the most important features. Given that the method is able to assess a whole MRSI grid faster than a spectroscopist (approximately 3 s versus approximately 3 min), and without loss of accuracy (agreement between classifier trained with just one session and any of the other labelling sessions, 89.88%; agreement between any two labelling sessions, 89.03%), the authors suggest its implementation in the clinical routine. The method presented in this article was implemented in jMRUI's SpectrIm plugin. Copyright © 2016 John Wiley & Sons, Ltd.
Value added products with popular low grade rice varieties of Andhra Pradesh.
Anitha, G; Rajyalakshmi, P
2014-12-01
Eight Popular Low Grade Rice Varieties (PLRVs) MTU 3626, MTU 1001, MTU 1010, MTU 4870 and NLR 145, NLR 34242, NLR 30491, NLR 34449, (developed and released by ANGR agricultural University, Andhra Pradesh) having poor cooking quality were selected for the study. ANGRAU variety BPT 5204 popularly consumed as staple rice was used as check. Eight products of traditional/commercial importance were standardized incorporating PLRVs as a major ingredient in the form of rice flour (burfi, noodles and extruded snack product and vennaundalu (butter coated balls), palathalikalu (dough rolled into strips, steamed/cooked in milk); rice semolina (instant kheer mix and instant upma mix), and flaked rice (nutritious bar). The products were evaluated for nutritional, cooking quality characteristics, consumer acceptability and shelf-life. Consumer acceptability of the PLR products was carried out with 60 farm women based on 9 point hedonic scale. Shelf-life of the products (packed in both metalized PP and PE pouches) was evaluated monthly for chemical, microbiological and sensory parameters. Energy values of control and PLR products showed no significant difference. Upon cooking, PLR Noodles showed no significant difference with water absorption and volume but more (p < 0.05) solid loss and cooked weight. Utilization of PLR flakes in nutritious bar resulted in highly crispy and crunchy texture, enhanced flavor and taste as compared to control. The percent total solids and suspended solids were more (though not significant) in PLR kheer and palathalikalu. Extruded product (control and PLR) showed no significant difference with length, diameter, weight and volume expansion ratio and water absorption index (WAI). Consumer acceptability was high for PLR products palathalikalu (95%), instant kheer mix (92%) and extruded product (88%). As per sensory scores, all the PLR products were well accepted with no observable changes in flavor or taste upon storage. PLR products showed increased (P < 0.05) trend for moisture and FFA content from initial to 90 days of storage. The lowest TPC was observed for noodles and highest for burfi (though in safe limits). Extruded snacks (control and PLR) showed no microbial growth during the entire storage period. Considering the poor marketability of PLRVs for consumption as staple rice, the study signifies the utilitarian value of PLRVs in making products of convenience/commercial importance.
Kuttner, Samuel; Bujila, Robert; Kortesniemi, Mika; Andersson, Henrik; Kull, Love; Østerås, Bjørn Helge; Thygesen, Jesper; Tarp, Ivanka Sojat
2013-03-01
Quality assurance (QA) of computed tomography (CT) systems is one of the routine tasks for medical physicists in the Nordic countries. However, standardized QA protocols do not yet exist and the QA methods, as well as the applied tolerance levels, vary in scope and extent at different hospitals. To propose a standardized protocol for acceptance and constancy testing of CT scanners in the Nordic Region. Following a Nordic Association for Clinical Physics (NACP) initiative, a group of medical physicists, with representatives from four Nordic countries, was formed. Based on international literature and practical experience within the group, a comprehensive standardized test protocol was developed. The proposed protocol includes tests related to the mechanical functionality, X-ray tube, detector, and image quality for CT scanners. For each test, recommendations regarding the purpose, equipment needed, an outline of the test method, the measured parameter, tolerance levels, and the testing frequency are stated. In addition, a number of optional tests are briefly discussed that may provide further information about the CT system. Based on international references and medical physicists' practical experiences, a comprehensive QA protocol for CT systems is proposed, including both acceptance and constancy tests. The protocol may serve as a reference for medical physicists in the Nordic countries.
Economic evaluations of tobacco control mass media campaigns: a systematic review
Atusingwize, Edwinah; Lewis, Sarah; Langley, Tessa
2015-01-01
Background International evidence shows that mass media campaigns are effective tobacco control interventions. However, they require substantial investment; a key question is whether their costs are justified by their benefits. The aim of this study was to systematically and comprehensively review economic evaluations of tobacco control mass media campaigns. Methods An electronic search of databases and grey literature was conducted to identify all published economic evaluations of tobacco control mass media campaigns. The authors reviewed studies independently and assessed the quality of studies using the Drummond 10-point checklist. A narrative synthesis was used to summarise the key features and quality of the identified studies. Results 10 studies met the inclusion criteria and were included in the review. All the studies included a cost effectiveness analysis, a cost utility analysis or both. The methods were highly heterogeneous, particularly in terms of the types of costs included. On the whole, studies were well conducted, but the interventions were often poorly described in terms of campaign content and intensity, and cost information was frequently inadequate. All studies concluded that tobacco control mass media campaigns are a cost effective public health intervention. Conclusions The evidence on the cost effectiveness of tobacco control mass media campaigns is limited, but of acceptable quality and consistently suggests that they offer good value for money. PMID:24985730
Data Assimilation Experiments using Quality Controlled AIRS Version 5 Temperature Soundings
NASA Technical Reports Server (NTRS)
Susskind, Joel
2008-01-01
The AIRS Science Team Version 5 retrieval algorithm has been finalized and is now operational at the Goddard DAAC in the processing (and reprocessing) of all AlRS data. Version 5 contains accurate case-by-case error estimates for most derived products, which are also used for quality control. We have conducted forecast impact experiments assimilating AlRS quality controlled temperature profiles using the NASA GEOS-5 data assimilation system, consisting of the NCEP GSI analysis coupled with the NASA FVGCM. Assimilation of quality controlled temperature profiles resulted in significantly improved forecast skill in both the Northern Hemisphere and Southern Hemisphere Extra-Tropics, compared to that obtained from analyses obtained when all data used operationally by NCEP except for AlRS data is assimilated. Experiments using different Quality Control thresholds for assimilation of AlRS temperature retrievals showed that a medium quality control threshold performed better than a tighter threshold, which provided better overall sounding accuracy; or a looser threshold, which provided better spatial coverage of accepted soundings. We are conducting more experiments to further optimize this balance of spatial coverage and sounding accuracy from the data assimilation perspective. In all cases, temperature soundings were assimilated well below cloud level in partially cloudy cases. The positive impact of assimilating AlRS derived atmospheric temperatures all but vanished when only AIRS stratospheric temperatures were assimilated. Forecast skill resulting from assimilation of AlRS radiances uncontaminated by clouds, instead of AlRS temperature soundings, was only slightly better than that resulting from assimilation of only stratospheric AlRS temperatures. This reduction in forecast skill is most likely the result of significant loss of tropospheric information when only AIRS radiances unaffected by clouds are used in the data assimilation process.
Luciano, Juan V; Guallar, José A; Aguado, Jaume; López-Del-Hoyo, Yolanda; Olivan, Bárbara; Magallón, Rosa; Alda, Marta; Serrano-Blanco, Antoni; Gili, Margalida; Garcia-Campayo, Javier
2014-04-01
In the last decade, there has been burgeoning interest in the effectiveness of third-generation psychological therapies for managing fibromyalgia (FM) symptoms. The present study examined the effectiveness of acceptance and commitment therapy (ACT) on functional status as well as the role of pain acceptance as a mediator of treatment outcomes in FM patients. A total of 156 patients with FM were enrolled at primary health care centers in Zaragoza, Spain. The patients were randomly assigned to a group-based form of ACT (GACT), recommended pharmacological treatment (RPT; pregabalin + duloxetine), or wait list (WL). The primary end point was functional status (measured with the Fibromyalgia Impact Questionnaire, FIQ). Secondary end points included pain catastrophizing, pain acceptance, pain, anxiety, depression, and health-related quality of life. The differences between groups were calculated by linear mixed-effects (intention-to-treat approach) and mediational models through path analyses. Overall, GACT was statistically superior to both RPT and WL immediately after treatment, and improvements were maintained at 6months with medium effect sizes in most cases. Immediately after treatment, the number needed to treat for 20% improvement compared to RPT was 2 (95% confidence interval 1.2-2.0), for 50% improvement 46, and for achieving a status of no worse than mild impaired function (FIQ total score <39) also 46. Unexpectedly, 4 of the 5 tested path analyses did not show a mediation effect. Changes in pain acceptance only mediated the relationship between study condition and health-related quality of life. These findings are discussed in relation to previous psychological research on FM treatment. Copyright © 2013 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
Zech, N; Hansen, E; Bernardy, K; Häuser, W
2017-02-01
This systematic review aimed at evaluating the efficacy, acceptability and safety of guided imagery/hypnosis (GI/H) in fibromyalgia. Cochrane Library, MEDLINE, PsycINFO and SCOPUS were screened through February 2016. Randomized controlled trials (RCTs) comparing GI/H with controls were analysed. Primary outcomes were ≥50% pain relief, ≥20% improvement of health-related quality of life, psychological distress, disability, acceptability and safety at end of therapy and 3-month follow-up. Effects were summarized by a random effects model using risk differences (RD) or standardized mean differences (SMD) with 95% confidence intervals (CI).Seven RCTs with 387 subjects were included into a comparison of GI/H versus controls. There was a clinically relevant benefit of GI/H compared to controls on ≥50% pain relief [RD 0.18 (95% CI 0.02, 0.35)] and psychological distress [SMD -0.40 (95% CI -0.70, -0.11)] at the end of therapy. Acceptability at the end of treatment for GI/H was not significantly different to the control. Two RCTs with 95 subjects were included in the comparison of hypnosis combined with cognitive behavioural therapy (CBT) versus CBT alone. Combined therapy was superior to CBT alone in reducing psychological distress at the end of therapy [SMD -0.50 (95% CI -0.91, -0.09)]. There were no statistically significant differences between combined therapy and CBT alone in other primary outcomes at the end of treatment and follow-up. No study reported on safety. GI/H hold promise in a multicomponent management of fibromyalgia. We provide a systematic review with meta-analysis on guided imagery and hypnosis for fibromyalgia. Current analyses endorse the efficacy and tolerability of guided imagery/hypnosis and of the combination of hypnosis with cognitive-behavioural therapy in reducing key symptoms of fibromyalgia. © 2016 European Pain Federation - EFIC®.
Litter quality impacts short- but not long-term soil carbon dynamics in soil aggregate fractions.
Gentile, Roberta; Vanlauwe, Bernard; Six, Johan
2011-04-01
Complex molecules are presumed to be preferentially stabilized as soil organic carbon (SOC) based on the generally accepted concept that the chemical composition of litter is a major factor in its rate of decomposition. Hence, a direct link between litter quality and SOC quantity has been assumed, accepted, and ultimately incorporated in SOC models. Here, however, we present data from an incubation and field experiment that refutes the influence of litter quality on the quantity of stabilized SOC. Three different qualities of litter (Tithonia diversifolia, Calliandra calothyrsus, and Zea mays stover; 4 Mg C x ha(-1) yr(-1)) with and without the addition of mineral N fertilizer (0 or 120 kg N x ha(-1)season(-1) were added to a red clay Humic Nitisol in a 3-yr field trial and a 1.5-yr incubation experiment. The litters differed in their concentrations of N, lignin, and polyphenols with the ratio of (lignin + polyphenols): N ranging from 3.5 to 9.8 for the field trial and from 2.3 to 4.0 for the incubation experiment in the order of T. diversifolia < C. calothyrsus < or = Z. mays. Litter quality did not affect the amount of SOC stabilized after three annual additions in the field trial. Even within the most sensitive soil aggregate fractions, SOC contents and C:N ratios did not differ with litter quality, indicating that litter quality did not influence the mechanisms by which SOC was stabilized. While increasing litter quality displayed faster decomposition and incorporation of C into soil aggregates after 0.25 yr in the incubation study, all litters resulted in equivalent amounts of C stabilized in the soil after 1.5 yr, further corroborating the results of the field trial. The addition of N fertilizer did not affect SOC stabilization in either the field or the incubation trial. Thus, we conclude that, while litter quality controls shorter-term dynamics of C decomposition and accumulation in the soil, longer-term SOC patterns cannot be predicted based on initial litter quality effects. Hence, the formation and stabilization of SOC is more controlled by the quantity of litter input and its interaction with the soil matrix than by litter quality.
NASA Astrophysics Data System (ADS)
Kim, Hyun-Joo; Jung, Samooel; Yong, Hae In; Bae, Young Sik; Kang, Suk Nam; Kim, Il Suk; Jo, Cheorun
2014-05-01
The combined effects of electron-beam (EB) irradiation and addition of onion peel (OP) extract and barbecue flavor (BF) on inactivation of foodborne pathogens and the quality of pork jerky was investigated. Prepared pork jerky samples were irradiated (0, 1, 2, and 4 kGy) and stored for 2 month at 25 °C. The D10 values of Listeria monocytogenes, Escherichia coli, and Salmonella typhimurium observed in the OP treated samples were 0.19, 0.18, and 0.19 kGy, whereas those in control were 0.25, 0.23, and 0.20 kGy, respectively. Irradiated samples with OP extract and BF had substantially lower total aerobic bacterial counts than the control had. Samples with added OP extract and BF had lower peroxide values than the control had. Sensory evaluation indicated that overall acceptability of treated samples was not changed up to 2 kGy. Therefore, EB irradiation, combined with OP extract and BF, has improved the microbiological safety with no negative effects on the quality of pork jerky.
Modeling, simulation, and flight characteristics of an aircraft designed to fly at 100,000 feet
NASA Technical Reports Server (NTRS)
Sim, Alex G.
1991-01-01
A manned real time simulation of a conceptual vehicle, the stratoplane, was developed to study the problems associated with the flight characteristics of a large, lightweight vehicle. Mathematical models of the aerodynamics, mass properties, and propulsion system were developed in support of the simulation and are presented. The simulation was at first conducted without control augmentation to determine the needs for a control system. The unaugmented flying qualities were dominated by lightly damped dutch roll oscillations. Constant pilot workloads were needed at high altitudes. Control augmentation was studied using basic feedbacks. For the longitudinal axis, flight path angle, and pitch rate feedback were sufficient to damp the phugoid mode and to provide good flying qualities. In the lateral directional axis, bank angle, roll rate, and yaw rate feedbacks were sufficient to provide a safe vehicle with acceptable handling qualities. Intentionally stalling the stratoplane to very high angles of attack (deep stall) was studied as a means of enable safe and rapid descent. It was concluded that the deep stall maneuver is viable for this class of vehicle.
Jenkins, Jill A.; Tiersch, Terrence R.
2011-01-01
Although cryopreservation of sperm has become an accepted technique for selective breeding and genetic improvement in livestock industries, no systematic approach is available for banking germplasm of aquatic species (i.e. embryos, semen and ova). The intent of this chapter is not to provide recommendations for specific measures to eliminate particular pathogens and subsequent diseases, but rather to develop a general framework and strategies for facing the new and unexpected. This chapter presents microbiological and quality assurance concerns for a cryopreservation program. In particular, the chapter identifies organisms transmittable in semen of animals, microorganisms and diseases of importance to aquatic species, pathogen detection issues, methods for prevention and control and how sperm quality can be assessed.
48 CFR 1346.503 - Place of acceptance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Place of acceptance. 1346.503 Section 1346.503 Federal Acquisition Regulations System DEPARTMENT OF COMMERCE CONTRACT MANAGEMENT QUALITY ASSURANCE Acceptance 1346.503 Place of acceptance. Insert a clause substantially similar to 1352...
DOT National Transportation Integrated Search
1979-08-01
Four workshops were conducted under the auspices of the Transportation Research Board. The topics of discussion included ride quality and passenger acceptance problems associated with enhanced fuel efficiency of automobiles (Group A) and aircraft (Gr...
Organisational Effectiveness in Military Organisations
1988-11-01
socialisatlon, an eq*msis on " belongingness " goals and a desire to maintain social solidarity in an increasingly individualistic social envirment. Cohm...statistical quality control and where employees often meet in their am time and usually receive a financial bcnus for the performance of the organisation. In...companies with more than 500 employees had QC programmes. ihle QCs have no decision making powrs, managers in many cases felt pressured to accept all
Ferreira, Valquíria C S; Morcuende, David; Hérnandez-López, Silvia H; Madruga, Marta S; Silva, Fábio A P; Estévez, Mario
2017-03-01
This study evaluated the impact of a phenolic-rich acorn extract (200 ppm gallic acid equivalents) and the concentration of oxygen in the packaging system (low-oxygen modified atmosphere; 5% vs. normal-oxygen; 21%) on lipid and protein oxidation and consumers acceptance of the ready-to-eat chicken patties. Samples were subjected to cooking (electric oven, 170 °C/16 min), cold storage (14 d at 4 °C), and reheating (microwave, 600 mW/1 min). Samples treated with acorn extract kept thiobarbituric acid-reactive substances numbers and lipid-derived volatiles at basal levels throughout the whole processing irrespective of the oxygen concentration in the packaging atmosphere. Consistently, treated patties had lower protein carbonyls than control ones. The acorn extract also controlled color and texture deterioration during chilled storage and reheating and improved the color and odor acceptance of the products. Formulating with acorn extract is a feasible strategy to inhibit the oxidation-driven changes and preserve the quality of reheated samples as if there were freshly cooked. Compared to the effect of the antioxidant extract, the concentration of oxygen in the packaging system was negligible in terms of quality preservation. © 2017 Institute of Food Technologists®.
Using tailored methodical approaches to achieve optimal science outcomes
NASA Astrophysics Data System (ADS)
Wingate, Lory M.
2016-08-01
The science community is actively engaged in research, development, and construction of instrumentation projects that they anticipate will lead to new science discoveries. There appears to be very strong link between the quality of the activities used to complete these projects, and having a fully functioning science instrument that will facilitate these investigations.[2] The combination of using internationally recognized standards within the disciplines of project management (PM) and systems engineering (SE) has been demonstrated to lead to achievement of positive net effects and optimal project outcomes. Conversely, unstructured, poorly managed projects will lead to unpredictable, suboptimal project outcomes ultimately affecting the quality of the science that can be done with the new instruments. The proposed application of these two specific methodical approaches, implemented as a tailorable suite of processes, are presented in this paper. Project management (PM) is accepted worldwide as an effective methodology used to control project cost, schedule, and scope. Systems engineering (SE) is an accepted method that is used to ensure that the outcomes of a project match the intent of the stakeholders, or if they diverge, that the changes are understood, captured, and controlled. An appropriate application, or tailoring, of these disciplines can be the foundation upon which success in projects that support science can be optimized.
Acceptance and Commitment Therapy for Problematic Internet Pornography Use: A Randomized Trial.
Crosby, Jesse M; Twohig, Michael P
2016-05-01
Problematic Internet pornography use is the inability to control the use of pornography, the experience of negative cognitions or emotions regarding pornography use, and the resulting negative effects on quality of life or general functioning. This study compared a 12-session individual protocol of acceptance and commitment therapy (ACT) for problematic Internet pornography use to a waitlist control condition with 28 adult males, all but 1 of whom were members of the Church of Jesus Christ of Latter-day Saints. Measures of self-reported pornography viewing, standardized measures of compulsive sexual behavior and related cognitions, and quality of life occurred at pretreatment, posttreatment, and 3-month follow-up. Results demonstrate significant between-condition reductions in pornography viewing compared to the waitlist condition (93% reduction ACT vs. 21% waitlist). When combining all participants (N=26), a 92% reduction was seen at posttreatment and an 86% reduction at 3-month follow-up. Complete cessation was seen in 54% of participants at posttreatment and at least a 70% reduction was seen in 93% of participants. At the 3-month follow-up assessment, 35% of participants showed complete cessation, with 74% of participants showing at least 70% reduction in viewing. Treatment suggestions and future directions are discussed. Copyright © 2016. Published by Elsevier Ltd.
Mazzoleni, Stefano; Montagnani, Giulia; Vagheggini, Guido; Buono, Lorenzo; Moretti, Francesca; Dario, Paolo; Ambrosino, Nicolino
2014-10-01
To evaluate the effectiveness of an interactive videogame (IV) system in addition to a supervised pulmonary rehabilitation programme (PRP) in patients with chronic respiratory diseases. Randomised Controlled Trial comparing standard PRP (20 patients, control group: CG), and PRP + sessions of interactive videogame-aided exercises (20 patients, experimental group: EG). Lung and respiratory muscle function, arterial blood gases, exercise capacity, dyspnoea, health status and health-related quality of life (HRQL) and emotional response were measured before and after PRP. A questionnaire on acceptability of the PRP was administered. Exercise capacity, dyspnoea and HRQL significantly improved in both groups after the PRP, whereas the EG showed a greater improvement in six-minute walk test and transitional dyspnoea index than the CG. No difference in psychological status or acceptability of PRP was observed between the two groups. The addition of IV training was more effective for improving some parameters of exercise tolerance and dyspnoea, although did not result in better psychological status nor it was better accepted than the standard PRP in patients with chronic respiratory diseases. Copyright © 2014 Elsevier Ltd. All rights reserved.
Hernández-Ávila, Juan Eugenio; Rodríguez, Mario-Henry; Santos-Luna, René; Sánchez-Castañeda, Veronica; Román-Pérez, Susana; Ríos-Salgado, Víctor Hugo; Salas-Sarmiento, Jesús Alberto
2013-01-01
Dengue fever incidence and its geographical distribution are increasing throughout the world. Quality and timely information is essential for its prevention and control. A web based, geographically enabled, dengue integral surveillance system (Dengue-GIS) was developed for the nation-wide collection, integration, analysis and reporting of geo-referenced epidemiologic, entomologic, and control interventions data. Consensus in the design and practical operation of the system was a key factor for its acceptance. Working with information systems already implemented as a starting point facilitated its acceptance by officials and operative personnel. Dengue-GIS provides the geographical detail needed to plan, asses and evaluate the impact of control activities. The system is beginning to be adopted as a knowledge base by vector control programs. It is used to generate evidence on impact and cost-effectiveness of control activities, promoting the use of information for decision making at all levels of the vector control program. Dengue-GIS has also been used as a hypothesis generator for the academic community. This GIS-based model system for dengue surveillance and the experience gathered during its development and implementation could be useful in other dengue endemic countries and extended to other infectious or chronic diseases. PMID:23936394
Systematic adaptation of data delivery
Bakken, David Edward
2016-02-02
This disclosure describes, in part, a system management component for use in a power grid data network to systematically adjust the quality of service of data published by publishers and subscribed to by subscribers within the network. In one implementation, subscribers may identify a desired data rate, a minimum acceptable data rate, desired latency, minimum acceptable latency and a priority for each subscription and the system management component may adjust the data rates in real-time to ensure that the power grid data network does not become overloaded and/or fail. In one example, subscriptions with lower priorities may have their quality of service adjusted before subscriptions with higher priorities. In each instance, the quality of service may be maintained, even if reduced, to meet or exceed the minimum acceptable quality of service for the subscription.
Robust, Decoupled, Flight Control Design with Rate Saturating Actuators
NASA Technical Reports Server (NTRS)
Snell, S. A.; Hess, R. A.
1997-01-01
Techniques for the design of control systems for manually controlled, high-performance aircraft must provide the following: (1) multi-input, multi-output (MIMO) solutions, (2) acceptable handling qualities including no tendencies for pilot-induced oscillations, (3) a tractable approach for compensator design, (4) performance and stability robustness in the presence of significant plant uncertainty, and (5) performance and stability robustness in the presence actuator saturation (particularly rate saturation). A design technique built upon Quantitative Feedback Theory is offered as a candidate methodology which can provide flight control systems meeting these requirements, and do so over a considerable part of the flight envelope. An example utilizing a simplified model of a supermaneuverable fighter aircraft demonstrates the proposed design methodology.
Radiation protection program for early detection of breast cancer in a mammography facility
NASA Astrophysics Data System (ADS)
Villagomez Casimiro, Mariana; Ruiz Trejo, Cesar; Espejo Fonseca, Ruby
2014-11-01
Mammography is the best tool for early detection of Breast Cancer. In this diagnostic radiology modality it is necessary to establish the criteria to ensure the proper use and operation of the equipment used to obtain mammographic images in order to contribute to the safe use of ionizing radiation. The aim of the work was to implement at FUCAM-AC the radiation protection program which must be established for patients and radiation workers according to Mexican standards [1-4]. To achieve this goal, radiation protection and quality control manuals were elaborated [5]. Furthermore, a quality control program (QCP) in the mammography systems (analog/digital), darkroom included, has been implemented. Daily sensitometry, non-variability of the image quality, visualizing artifacts, revision of the equipment mechanical stability, compression force and analysis of repetition studies are some of the QCP routine tests that must be performed by radiological technicians of this institution as a set of actions to ensure the protection of patients. Image quality and patients dose assessment were performed on 4 analog equipment installed in 2 mobile units. In relation to dose assessment, all equipment passed the acceptance criteria (<3 mGy per projection). The image quality test showed that most images (70%)- presented artifacts. A brief summary of the results of quality control tests applied to the equipment and film processor are presented. To maintain an adequate level of quality and safety at FUCAM-AC is necessary that the proposed radiation protection program in this work is applied.
DOT National Transportation Integrated Search
2011-07-01
This project investigated the use of a surface resistivity device as an indication of concretes ability to resist chloride ion penetration for use in quality assurance (QA) and acceptance of high performance concrete (HPC). : The objectives of thi...
Online Support Service Quality, Online Learning Acceptance, and Student Satisfaction
ERIC Educational Resources Information Center
Lee, Jung-Wan
2010-01-01
This paper examines potential differences between Korean and American students in terms of their perception levels regarding online education support service quality, online learning acceptance, and satisfaction. Eight hundred and seventy-two samples, which were collected from students in online classes in the United States and Korea, were…
A pragmatic guide on how physicians can take over financial control of their clinical practice.
Jacobs, Volker R; Fischer, Thorsten
2012-01-01
Control of clinical cost is becoming increasingly important in health care worldwide. Physicians should accept the limitation of resources and take responsibility to improve their clinical cost-reimbursement ratio. To achieve this, they will need basic education in clinic management to control and adjust costs and reimbursement, without impacting professional quality of care. Rational use of diagnostics and therapy should be implemented and frequently verified. Physicians are the only professionals that are able to integrate economics with health care. This is in the best interest of patients and will improve a physician's position, influence, and professional freedom levels within our hospitals.
Franchising of health services in low-income countries.
Montagu, Dominic
2002-06-01
Grouping existing providers under a franchised brand, supported by training, advertising and supplies, is a potentially important way of improving access to and assuring quality of some types of clinical medical services. While franchising has great potential to increase service delivery points and method acceptability, a number of challenges are inherent to the delivery model: controlling the quality of services provided by independent practitioners is difficult, positioning branded services to compete on either price or quality requires trade-offs between social goals and provider satisfaction, and understanding the motivations of clients may lead to organizational choices which do not maximize quality or minimize costs. This paper describes the structure and operation of existing franchises and presents a model of social franchise activities that will afford a context for analyzing choices in the design and implementation of health-related social franchises in developing countries.
Self-assessment procedure using fuzzy sets
NASA Astrophysics Data System (ADS)
Mimi, Fotini
2000-10-01
Self-Assessment processes, initiated by a company itself and carried out by its own people, are considered to be the starting point for a regular strategic or operative planning process to ensure a continuous quality improvement. Their importance has increased by the growing relevance and acceptance of international quality awards such as the Malcolm Baldrige National Quality Award, the European Quality Award and the Deming Prize. Especially award winners use the instrument of a systematic and regular Self-Assessment and not only because they have to verify their quality and business results for at least three years. The Total Quality Model of the European Foundation for Quality Management (EFQM), used for the European Quality Award, is the basis for Self-Assessment in Europe. This paper presents a self-assessment supporting method based on a methodology of fuzzy control systems providing an effective means of converting the linguistic approximation into an automatic control strategy. In particular, the elements of the Quality Model mentioned above are interpreted as linguistic variables. The LR-type of a fuzzy interval is used for their representation. The input data has a qualitative character based on empirical investigation and expert knowledge and therefore the base- variables are ordinal scaled. The aggregation process takes place on the basis of a hierarchical structure. Finally, in order to render the use of the method more practical a software system on PC basis is developed and implemented.
Chow, Judith C; Watson, John G; Robles, Jerome; Wang, Xiaoliang; Chen, L-W Antony; Trimble, Dana L; Kohl, Steven D; Tropp, Richard J; Fung, Kochy K
2011-12-01
Accurate, precise, and valid organic and elemental carbon (OC and EC, respectively) measurements require more effort than the routine analysis of ambient aerosol and source samples. This paper documents the quality assurance (QA) and quality control (QC) procedures that should be implemented to ensure consistency of OC and EC measurements. Prior to field sampling, the appropriate filter substrate must be selected and tested for sampling effectiveness. Unexposed filters are pre-fired to remove contaminants and acceptance tested. After sampling, filters must be stored in the laboratory in clean, labeled containers under refrigeration (<4 °C) to minimize loss of semi-volatile OC. QA activities include participation in laboratory accreditation programs, external system audits, and interlaboratory comparisons. For thermal/optical carbon analyses, periodic QC tests include calibration of the flame ionization detector with different types of carbon standards, thermogram inspection, replicate analyses, quantification of trace oxygen concentrations (<100 ppmv) in the helium atmosphere, and calibration of the sample temperature sensor. These established QA/QC procedures are applicable to aerosol sampling and analysis for carbon and other chemical components.
Kouassi, Kafui; Fétéké, Lochina; Assignon, Selom; Dorkenoo, Ameyo; Napo-Koura, Gado
2015-01-01
This study aims to evaluate the performance of a few biochemistry analysis and make recommendations to the place of the stakeholders. It is a cross-sectional study conducted between the October 1(st), 2012 and the July 31, 2013 bearing on the results of 5 common examinations of clinical biochemistry, provided by 11 laboratories volunteers opening in the public and private sectors. These laboratories have analysed during the 3 cycles, 2 levels (medium and high) of serum concentration of urea, glucose, creatinine and serum aminotransferases. The performance of laboratories have been determined from the acceptable limits corresponding to the limits of total errors, defined by the French Society of Clinical Biology (SFBC). A system of internal quality control is implemented by all laboratories and 45% of them participated in international programs of external quality assessment (EQA). The rate of acceptable results for the entire study was of 69%. There was a significant difference (p<0.002) between the performance of the group of laboratories engaged in a quality approach and the group with default implementation of the quality approach. Also a significant difference was observed between the laboratories of the central level and those of the peripheral level of our health system (p<0.047). The performance of the results provided by the laboratories remains relatively unsatisfactory. It is important that the Ministry of Health put in place a national program of EQA with mandatory participation.
Introducing a quality improvement programme to primary healthcare teams
Hearnshaw, H.; Reddish, S.; Carlyle, D.; Baker, R.; Robertson, N.
1998-01-01
OBJECTIVES: To evaluate a programme in which quality improvement was facilitated, based on principles of total quality management, in primary healthcare teams, and to determine its feasibility, acceptability, effectiveness, and the duration of its effect. METHOD: Primary healthcare teams in Leicestershire (n = 147) were invited to take part in the facilitated programme. The programme comprised seven team meetings, led by a researcher, plus up to two facilitated meetings of quality improvement subgroups, appointed by each team to consider specific quality issues. OUTCOME MEASURES: To assess the effect and feasibility of the programme on improving the quality of care provided, the individual quality improvement projects undertaken by the teams were documented and opportunities for improvement were noted at each session by the facilitator. The programme's acceptability was assessed with questionnaires issued in the final session to each participant. To assess the long term impact on teams, interviews with team members were conducted 3 years after the programme ended. RESULTS: 10 of the 27 teams that initially expressed interest in the programme agreed to take part, and six started the programme. Of these, five completed their quality improvement projects and used several different quality tools, and three completed all seven sessions of the programme. The programme was assessed as appropriate and acceptable by the participants. Three years later, the changes made during the programme were still in place in three of the six teams. Four teams had decided to undertake the local quality monitoring programme, resourced and supported by the Health Authority. CONCLUSIONS: The facilitated programme was feasible, acceptable, and effective for a few primary healthcare teams. The outcomes of the programme can be sustained. Research is needed on the characteristics of teams likely to be successful in the introduction and maintenance of quality improvement programmes. PMID:10339022
Wannheden, Carolina; Hvitfeldt-Forsberg, Helena; Eftimovska, Elena; Westling, Katarina; Ellenius, Johan
2017-08-11
The care of HIV-related tuberculosis (HIV/TB) is complex and challenging. Clinical decision support (CDS) systems can contribute to improve quality of care, but more knowledge is needed on factors determining user acceptance of CDS. To analyze physicians' and nurses' acceptance of a CDS prototype for evidence-based drug therapy recommendations for HIV/TB treatment. Physicians and nurses were involved in designing a CDS prototype intended for future integration with the Swedish national HIV quality registry. Focus group evaluation was performed with ten nurses and four physicians, respectively. The Unified Theory of Acceptance and Use of Technology (UTAUT) was used to analyze acceptance. We identified several potential benefits with the CDS prototype as well as some concerns that could be addressed by redesign. There was also concern about dependence on physician attitudes, as well as technical, organizational, and legal issues. Acceptance evaluation at a prototype stage provided rich data to improve the future design of a CDS prototype. Apart from design and development efforts, substantial organizational efforts are needed to enable the implementation and maintenance of a future CDS system.
Berendes, Sima; Lako, Richard L; Whitson, Donald; Gould, Simon; Valadez, Joseph J
2014-10-01
We adapted a rapid quality of care monitoring method to a fragile state with two aims: to assess the delivery of child health services in South Sudan at the time of independence and to strengthen local capacity to perform regular rapid health facility assessments. Using a two-stage lot quality assurance sampling (LQAS) design, we conducted a national cross-sectional survey among 156 randomly selected health facilities in 10 states. In each of these facilities, we obtained information on a range of access, input, process and performance indicators during structured interviews and observations. Quality of care was poor with all states failing to achieve the 80% target for 14 of 19 indicators. For example, only 12% of facilities were classified as acceptable for their adequate utilisation by the population for sick-child consultations, 16% for staffing, 3% for having infection control supplies available and 0% for having all child care guidelines. Health worker performance was categorised as acceptable in only 6% of cases related to sick-child assessments, 38% related to medical treatment for the given diagnosis and 33% related to patient counselling on how to administer the prescribed drugs. Best performance was recorded for availability of in-service training and supervision, for seven and ten states, respectively. Despite ongoing instability, the Ministry of Health developed capacity to use LQAS for measuring quality of care nationally and state-by-state, which will support efficient and equitable resource allocation. Overall, our data revealed a desperate need for improving the quality of care in all states. © 2014 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Wade, Cherrie; Brennan, Patrick C.; Mc Entee, Mark F.
2005-04-01
Diagnostic efficacy in soft-copy reporting relies heavily on the quality of workstation monitors and an investigation performed in 2002 demonstrated that CRT monitors in Dublin imaging departments were not operating at optimal levels. The current work examines the performance of CRTs being used in Dublin and other parts of Ireland to establish if problems reported in the earlier work have been rectified. All hospitals performing soft-copy reporting for general radiology using CRTs were included in the work. Examination of ambient lighting, calibration of monitors and analysis of CRT performance using the SMPTE test pattern and a selection of the AAPM test images was performed. Maximum luminance, spatial uniformity of luminance, temporal luminance stability, gamma, geometry, sharpness, veiling glare and spatial resolution of each monitor was evaluated. Ambient lighting in all reporting areas was within recommended levels. All the monitors were calibrated appropriately and were performing at acceptable levels for maximum luminance and temporal stability and only one of the thirty-three investigated failed to reach the standard for spatial uniformity. In contrast a number of the CRTs investigated showed poor adherence to acceptable levels for geometrical distortions, veiling glare and spatial resolution all of which are important influencers of image quality. Gamma values also appeared to be low for a number of monitors but this interpretation is provisional and subject to the establishment of ratified guideline values. The results demonstrate that although some improvement on the previous situation is evident, greater adherence to acceptable levels is required for certain parameters.
An Application of Six Sigma to Reduce Supplier Quality Cost
NASA Astrophysics Data System (ADS)
Gaikwad, Lokpriya Mohanrao; Teli, Shivagond Nagappa; Majali, Vijay Shashikant; Bhushi, Umesh Mahadevappa
2016-01-01
This article presents an application of Six Sigma to reduce supplier quality cost in manufacturing industry. Although there is a wider acceptance of Six Sigma in many organizations today, there is still a lack of in-depth case study of Six Sigma. For the present research the case study methodology was used. The company decided to reduce quality cost and improve selected processes using Six Sigma methodologies. Regarding the fact that there is a lack of case studies dealing with Six Sigma especially in individual manufacturing organization this article could be of great importance also for the practitioners. This paper discusses the quality and productivity improvement in a supplier enterprise through a case study. The paper deals with an application of Six Sigma define-measure-analyze-improve-control methodology in an industry which provides a framework to identify, quantify and eliminate sources of variation in an operational process in question, to optimize the operation variables, improve and sustain performance viz. process yield with well-executed control plans. Six Sigma improves the process performance (process yield) of the critical operational process, leading to better utilization of resources, decreases variations and maintains consistent quality of the process output.
Guidelines for Risk-Based Changeover of Biopharma Multi-Product Facilities.
Lynch, Rob; Barabani, David; Bellorado, Kathy; Canisius, Peter; Heathcote, Doug; Johnson, Alan; Wyman, Ned; Parry, Derek Willison
2018-01-01
In multi-product biopharma facilities, the protection from product contamination due to the manufacture of multiple products simultaneously is paramount to assure product quality. To that end, the use of traditional changeover methods (elastomer change-out, full sampling, etc.) have been widely used within the industry and have been accepted by regulatory agencies. However, with the endorsement of Quality Risk Management (1), the use of risk-based approaches may be applied to assess and continuously improve established changeover processes. All processes, including changeover, can be improved with investment (money/resources), parallel activities, equipment design improvements, and standardization. However, processes can also be improved by eliminating waste. For product changeover, waste is any activity not needed for the new process or that does not provide added assurance of the quality of the subsequent product. The application of a risk-based approach to changeover aligns with the principles of Quality Risk Management. Through the use of risk assessments, the appropriate changeover controls can be identified and controlled to assure product quality is maintained. Likewise, the use of risk assessments and risk-based approaches may be used to improve operational efficiency, reduce waste, and permit concurrent manufacturing of products. © PDA, Inc. 2018.
Riedl, David; Rumpold, Gerhard; Schmidt, Annette; Zorowka, Patrick G.; Bliem, Harald R.; Moschen, Roland
2015-01-01
Recent findings show the importance of acceptance in the treatment of chronic tinnitus. So far, very limited research investigating the different levels of tinnitus acceptance has been conducted. The aim of this study was to investigate the quality of life (QoL) and psychological distress in patients with chronic tinnitus who reported different levels of tinnitus acceptance. The sample consisted of outpatients taking part in a tinnitus coping group (n = 97). Correlations between tinnitus acceptance, psychological distress, and QoL were calculated. Receiver operating characteristic (ROC) curves were used to calculate a cutoff score for the German “Tinnitus Acceptance Questionnaire” (CTAQ-G) and to evaluate the screening abilities of the CTAQ-G. Independent sample t-tests were conducted to compare QoL and psychological distress in patients with low tinnitus acceptance and high tinnitus acceptance. A cutoff point for CTAQ-G of 62.5 was defined, differentiating between patients with “low-to-mild tinnitus acceptance” and “moderate-to-high tinnitus acceptance.” Patients with higher levels of tinnitus acceptance reported a significantly higher QoL and lower psychological distress. Tinnitus acceptance plays an important role for patients with chronic tinnitus. Increased levels of acceptance are related to better QoL and less psychological distress. PMID:26356381
WHO Expert Committee on Specifications for Pharmaceutical Preparations.
2003-01-01
This report presents the recommendations of an international group of experts convened by the World Health Organization to consider matters concerning the quality assurance of pharmaceuticals and specifications for drug substances and dosage forms. Of particular relevance to drug regulatory authorities and pharmaceutical manufacturers, the report discusses activities related to the development of The International Pharmacopoeia and basic tests for pharmaceutical substances and dosage forms, as well as quality control of reference materials, good manufacturing practices (GMP), stability studies, inspection, hazard analysis, procurement, storage and other aspects of quality assurance of pharmaceuticals, and regulatory issues. The report is complemented by a number of annexes, including recommendations on the risk of transmitting animal spongiform encephalopathy agents via medicinal products, guidelines on GMP for pharmaceutical products, a model certificate for GMP and guidance on a GMP inspection report. The final annexes provide guidance on the application of Hazard Analysis and Critical Control Point (HACCP) method to pharmaceuticals, good storage practices and a procedure for assessing acceptability of pharmaceutical products for purchase by United Nations agencies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lindberg, Michael J.
2010-09-28
Between October 14, 2009 and February 22, 2010 sediment samples were received from 100-BC Decision Unit for geochemical studies. This is an analytical data report for sediments received from CHPRC at the 100 BC 5 OU. The analyses for this project were performed at the 325 building located in the 300 Area of the Hanford Site. The analyses were performed according to Pacific Northwest National Laboratory (PNNL) approved procedures and/or nationally recognized test procedures. The data sets include the sample identification numbers, analytical results, estimated quantification limits (EQL), and quality control data. The preparatory and analytical quality control requirements, calibrationmore » requirements, acceptance criteria, and failure actions are defined in the on-line QA plan 'Conducting Analytical Work in Support of Regulatory Programs' (CAW). This QA plan implements the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD) for PNNL.« less
Flegar-Mestrić, Zlata; Nazor, Aida; Perkov, Sonja; Surina, Branka; Kardum-Paro, Mirjana Mariana; Siftar, Zoran; Sikirica, Mirjana; Sokolić, Ivica; Ozvald, Ivan; Vidas, Zeljko
2010-03-01
Since 2003 when the international norm for implementation of quality management in medical laboratories (EN ISO 15189, Medical laboratories--Particular requirements for quality and competence) was established and accepted, accreditation has become practical, generally accepted method of quality management and confirmation of technical competence of medical laboratories in the whole world. This norm has been translated into Croatian and accepted by the Croatian Institute for Norms as Croatian norm. Accreditation is carried out on voluntary basis by the Croatian Accreditation Agency that has up to now accredited two clinical medical biochemical laboratories in the Republic of Croatia. Advantages of accredited laboratory lie in its documented management system, constant improvement and training, reliability of test results, establishing users' trust in laboratory services, test results comparability and interlaboratory (international) test results acceptance by adopting the concept of metrological traceability in laboratory medicine.
Correia, Sofia; Schouten, Rob; Silva, Ana P.; Gonçalves, Berta
2017-01-01
Sweet cherries are attractive fruits due to their taste, color, nutritional value, and beneficial health effects. Sweet cherry is a highly perishable fruit and all quality attributes and the level of health promoting compounds are affected by growth conditions, picking, packing, transport, and storage. During production, the correct combination of scion × rootstock will produce fruits with higher firmness, weight, sugars, vitamins, and phenolic compounds that boost the fruit antioxidant activity. Orchard management, such as applying drip irrigation and summer pruning, will increase fruit sugar levels and total phenolic content, while application of growth regulators can result in improved storability, increased red coloring, increased fruit size, and reduced cracking. Salicylic acid, oxalic acid, acetylsalicylic acid, and methyl salicylate are promising growth regulators as they also increase total phenolics, anthocyanins, and induce higher activity of antioxidant enzymes. These growth regulators are now also applied as fruit coatings that improve shelf-life with higher antioxidant enzyme activities and total phenolics. Optimizing storage and transport conditions, such as hydro cooling with added CaCl2, chain temperature and relative humidity control, are crucial for slowing down decay of quality attributes and increasing the antioxidant capacity. Application of controlled atmosphere during storage is successful in delaying quality attributes, but lowers ascorbic acid levels. The combination of low temperature storage in combination with modified atmosphere packaging (MAP) is successful in reducing the incidence of fruit decay, while preserving taste attributes and stem color with a higher antioxidant capacity. A new trend in MAP is the use of biodegradable films such as micro-perforated polylactic acid film that combine significant retention of quality attributes, high consumer acceptability, and a reduced environmental footprint. Another trend is to replace MAP with fruit edible coatings. Edible coatings, such as various lipid composite coatings, have advantages in retaining quality attributes and increasing the antioxidant activity (chitosan) and are regarded as approved food additives, although studies regarding consumer acceptance are needed. The recent publication of the sweet cherry genome will likely increase the identification of more candidate genes involved in growing and maintaining health related compounds and quality attributes. PMID:29312407
Shephard, Mark; Shephard, Anne; McAteer, Bridgit; Regnier, Tamika; Barancek, Kristina
2017-12-01
Diabetes is a major health problem for Australia's Aboriginal and Torres Strait Islander peoples. Point-of-care testing for haemoglobin A1c (HbA1c) has been the cornerstone of a long-standing program (QAAMS) to manage glycaemic control in Indigenous people with diabetes and recently, to diagnose diabetes. The QAAMS quality management framework includes monthly testing of quality control (QC) and external quality assurance (EQA) samples. Key performance indicators of quality include imprecision (coefficient of variation [CV%]) and percentage acceptable results. This paper reports on the past 15years of quality testing in QAAMS and examines the performance of HbA1c POC testing at the 6.5% cut-off recommended for diagnosis. The total number of HbA1c EQA results submitted from 2002 to 2016 was 29,093. The median imprecision for EQA testing by QAAMS device operators averaged 2.81% (SD 0.50; range 2.2 to 3.9%) from 2002 to 2016 and 2.44% (SD 0.22; range 2.2 to 2.9%) from 2009 to 2016. No significant difference was observed between the median imprecision achieved in QAAMS and by Australasian laboratories from 2002 to 2016 (p=0.05; two-tailed paired t-test) and from 2009 to 2016 (p=0.17; two-tailed paired t-test). For QC testing from 2009 to 2016, imprecision averaged 2.5% and 3.0% for the two levels of QC tested. Percentage acceptable results averaged 90% for QA testing from 2002 to 2016 and 96% for QC testing from 2009 to 2016. The DCA Vantage was able to measure a patient and an EQA sample with an HbA1c value close to 6.5% both accurately and precisely. HbA1c POC testing in QAAMS has remained analytically sound, matched the quality achieved by Australasian laboratories and met profession-derived analytical goals for 15years. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Bäuerle, Kathrin; Feicke, Janine; Scherer, Wolfgang; Spörhase, Ulrike; Bitzer, Eva-Maria
2017-05-01
To modify and evaluate a patient education program for adult asthma patients in consideration of quality criteria for teaching. This was a prospective single-center controlled trial in an inpatient rehabilitation center. The control group (n=215) received the usual lecture-based education program, and the intervention group (n=209) the modified patient education program. Data were assessed at admission, discharge, 6 and 12 months post discharge. The primary outcome was asthma control, the secondary outcomes were asthma knowledge, quality of life, and program acceptance. Analysis of change was performed by ANCOVA for each follow-up, adjusting for baseline values. Statistically significant increases in all health outcomes and in asthma control were maintained in both groups at 12 months: CG: +1.9 (95%-CI 1.3-2.6) IG: +1.6 (95%-CI 0.8-2.3). We observed no significant differences between the programs for asthma control and quality of life. Regarding practical asthma knowledge, after 12 months, a group*time interaction emerged with a small effect size (P=0.06, η2=0.01). The modified program was not superior to traditional patient education concerning asthma control. It permanently increased self-management knowledge. Structured and behavioral patient education fosters patient's disease management ability. Possible ways of improving asthma control need to be explored. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
A routine quality assurance test for CT automatic exposure control systems.
Iball, Gareth R; Moore, Alexis C; Crawford, Elizabeth J
2016-07-08
The study purpose was to develop and validate a quality assurance test for CT automatic exposure control (AEC) systems based on a set of nested polymethylmethacrylate CTDI phantoms. The test phantom was created by offsetting the 16 cm head phantom within the 32 cm body annulus, thus creating a three part phantom. This was scanned at all acceptance, routine, and some nonroutine quality assurance visits over a period of 45 months, resulting in 115 separate AEC tests on scanners from four manufacturers. For each scan the longitudinal mA modulation pattern was generated and measurements of image noise were made in two annular regions of interest. The scanner displayed CTDIvol and DLP were also recorded. The impact of a range of AEC configurations on dose and image quality were assessed at acceptance testing. For systems that were tested more than once, the percentage of CTDIvol values exceeding 5%, 10%, and 15% deviation from baseline was 23.4%, 12.6%, and 8.1% respectively. Similarly, for the image noise data, deviations greater than 2%, 5%, and 10% from baseline were 26.5%, 5.9%, and 2%, respectively. The majority of CTDIvol and noise deviations greater than 15% and 5%, respectively, could be explained by incorrect phantom setup or protocol selection. Barring these results, CTDIvol deviations of greater than 15% from baseline were found in 0.9% of tests and noise deviations greater than 5% from baseline were found in 1% of tests. The phantom was shown to be sensitive to changes in AEC setup, including the use of 3D, longitudinal or rotational tube current modulation. This test methodology allows for continuing performance assessment of CT AEC systems, and we recommend that this test should become part of routine CT quality assurance programs. Tolerances of ± 15% for CTDIvol and ± 5% for image noise relative to baseline values should be used. © 2016 The Authors
Luciano, Juan V; D'Amico, Francesco; Feliu-Soler, Albert; McCracken, Lance M; Aguado, Jaume; Peñarrubia-María, María T; Knapp, Martin; Serrano-Blanco, Antoni; García-Campayo, Javier
2017-07-01
The aim of this study was to analyze the cost utility of a group-based form of acceptance and commitment therapy (GACT) in patients with fibromyalgia (FM) compared with patients receiving recommended pharmacological treatment (RPT) or on a waiting list (WL). The data were derived from a previously published study, a randomized controlled trial that focused on clinical outcomes. Health economic outcomes included health-related quality of life and health care use at baseline and at 6-month follow-up using the EuroQoL and the Client Service Receipt Inventory, respectively. Analyses included quality-adjusted life years, direct and indirect cost differences, and incremental cost effectiveness ratios. A total of 156 FM patients were randomized (51 GACT, 52 RPT, 53 WL). GACT was related to significantly less direct costs over the 6-month study period compared with both control arms (GACT €824.2 ± 1,062.7 vs RPT €1,730.7 ± 1,656.8 vs WL €2,462.7 ± 2,822.0). Lower direct costs for GACT compared with RPT were due to lower costs from primary care visits and FM-related medications. The incremental cost effectiveness ratios were dominant in the completers' analysis and remained robust in the sensitivity analyses. In conclusion, acceptance and commitment therapy appears to be a cost-effective treatment compared with RPT in patients with FM. Decision-makers have to prioritize their budget on the treatment option that is the most cost effective for the management of a specific patient group. From government as well as health care perspectives, this study shows that a GACT is more cost effective than pharmacological treatment in management of FM. Copyright © 2017 American Pain Society. Published by Elsevier Inc. All rights reserved.
Moss, Aleezé S; Reibel, Diane K; Greeson, Jeffrey M; Thapar, Anjali; Bubb, Rebecca; Salmon, Jacqueline; Newberg, Andrew B
2015-06-01
The purpose of this study was to test the feasibility and effectiveness of an adapted 8-week Mindfulness-Based Stress Reduction (MBSR) program for elders in a continuing care community. This mixed-methods study used both quantitative and qualitative measures. A randomized waitlist control design was used for the quantitative aspect of the study. Thirty-nine elderly were randomized to MBSR (n = 20) or a waitlist control group (n = 19), mean age was 82 years. Both groups completed pre-post measures of health-related quality of life, acceptance and psychological flexibility, facets of mindfulness, self-compassion, and psychological distress. A subset of MBSR participants completed qualitative interviews. MBSR participants showed significantly greater improvement in acceptance and psychological flexibility and in role limitations due to physical health. In the qualitative interviews, MBSR participants reported increased awareness, less judgment, and greater self-compassion. Study results demonstrate the feasibility and potential effectiveness of an adapted MBSR program in promoting mind-body health for elders. © The Author(s) 2014.
[Operation room management in quality control certification of a mainstream hospital].
Leidinger, W; Meierhofer, J N; Schüpfer, G
2006-11-01
We report the results of our study concerning the organisation of operating room (OR) capacity planned 1 year in advance. The use of OR is controlled using 2 global controlling numbers: a) the actual time difference between the expected optimal and previously calculated OR running time and b) the punctuality of starting the first operation in each OR. The focal point of the presented OR management concept is a consensus-oriented decision-making and steering process led by a coordinator who achieves a high degree of acceptance by means of comprehensive transparency. Based on the accepted running time, the optimal productivity of OR's (OP_A(%) can be calculated. In this way an increase of the overall capacity (actual running time) of ORs was from 40% to over 55% was achieved. Nevertheless, enthusiasm and teamwork from all persons involved in the system are vital for success as well as a completely independent operating theatre manager. Using this concept over 90% of the requirements for the new certification catalogue for hospitals in Germany was achieved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Compliance with acceptable quality level and passing and failing criteria for selective enforcement audits. 89.510 Section 89.510... EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Selective Enforcement Auditing § 89.510...
32 CFR 154.35 - Personal data provided by the subject of the investigation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... appropriate investigative forms, provide fingerprints of a quality acceptable to the FBI, and execute a signed... a fingerprint card indicating that the quality of the fingerprints is not acceptable, an additional set of fingerprints will be obtained from the subject. In the event the FBI indicates that the...
32 CFR 154.35 - Personal data provided by the subject of the investigation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... appropriate investigative forms, provide fingerprints of a quality acceptable to the FBI, and execute a signed... a fingerprint card indicating that the quality of the fingerprints is not acceptable, an additional set of fingerprints will be obtained from the subject. In the event the FBI indicates that the...
32 CFR 154.35 - Personal data provided by the subject of the investigation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... appropriate investigative forms, provide fingerprints of a quality acceptable to the FBI, and execute a signed... a fingerprint card indicating that the quality of the fingerprints is not acceptable, an additional set of fingerprints will be obtained from the subject. In the event the FBI indicates that the...
32 CFR 154.35 - Personal data provided by the subject of the investigation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... appropriate investigative forms, provide fingerprints of a quality acceptable to the FBI, and execute a signed... a fingerprint card indicating that the quality of the fingerprints is not acceptable, an additional set of fingerprints will be obtained from the subject. In the event the FBI indicates that the...
32 CFR 154.35 - Personal data provided by the subject of the investigation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... appropriate investigative forms, provide fingerprints of a quality acceptable to the FBI, and execute a signed... a fingerprint card indicating that the quality of the fingerprints is not acceptable, an additional set of fingerprints will be obtained from the subject. In the event the FBI indicates that the...
Social acceptance and self-esteem: tuning the sociometer to interpersonal value.
Anthony, Danu B; Holmes, John G; Wood, Joanne V
2007-06-01
The authors draw on sociometer theory to propose that self-esteem is attuned to traits that garner others' acceptance, and the traits that garner acceptance depend on one's social role. Attunement of self-esteem refers to the linkage, or connection, between self-esteem and specific traits, which may be observed most clearly in the association between self-esteem and specific self-evaluations. In most roles, appearance and popularity determine acceptance, so self-esteem is most attuned to those traits. At the same time, interdependent social roles emphasize the value of communal qualities, so occupants of those roles have self-esteem that is more attuned to communal qualities than is the general norm. To avoid the biases of people's personal theories, the authors assessed attunement of self-esteem to particular traits indirectly via the correlation between self-esteem and self-ratings, cognitive accessibility measures, and an experiment involving social decision making. As hypothesized, self-esteem was generally more attuned to appearances than to communal qualities, but interdependent social roles predicted heightened attunement of self-esteem to qualities like kindness and understanding. (c) 2007 APA, all rights reserved.
Seo, Hyun-Woo; Seo, Jin-Kyu; Yang, Han-Sul
2016-01-01
This study investigated the effects of bovine plasma protein (PP) hydrolysates on the antioxidant and quality properties of pork patties during storage. Pork patties were divided into 4 groups: without butylated hydroxytoluene (BHT) and PP hydrolysates (control), 0.02% BHT (T1), 1% PP hydrolysates (T2), and 2% PP hydrolysates (T3). Pork patty supplemented with PP hydrolysates had higher pH values and lower weight loss during cooking than the control patties. Results showed that lightness and hardness both decreased upon the addition of PP hydrolysates. All samples containing BHT and PP hydrolysates had reduced TBARS and peroxide values during storage. In particular, 2% PP hydrolysates were more effective in delaying lipid oxidation than were the other treatments. It was concluded that treatment with 2% PP hydrolysates can enhance the acceptance of pork patty.
Yoshida, Mitsuru
2014-08-01
Japanese food self-sufficiency was only 39% on the basis of kcal in 2012, so Japan relies heavily on imported food. Hence the necessity of having international rules on the regulation of food contaminants is important especially for countries like Japan that depend on food imports. A One-Stop-Testing system is desired, in which the test result obtained from a single testing laboratory is accepted as valid worldwide. To establish this system, laboratory accreditation under international standards is a necessary step. Furthermore, the importance of supply of reference materials for internal quality control and proficiency testing for external quality control of each laboratory's analytical system is reviewed in connection with the experience of radioactive nuclide contamination resulting from the Fukushima nuclear power plant accident in March 2011. © 2013 Society of Chemical Industry.
Choi, Yun-Sang; Kim, Hyun-Wook; Kim, Young-Boong; Jeon, Ki-Hong
2015-01-01
In this study, we evaluated the effects of dietary fiber extracted from Algelica keiskei Koidz on the chemical composition, cooking characteristics, and sensory properties of chicken patties. The chicken patties with Algelica keiskei Koidz dietary fiber had significantly higher moisture and ash content, and yellowness than the control sample (p<0.05). Energy value, cooking loss, reduction in diameter, reduction in thickness, lightness, redness, hardness, cohesiveness, gumminess, and chewiness of the control samples was significantly higher than chicken patties with Algelica keiskei Koidz dietary fiber (p<0.05). The sensory evaluation indicated that the greatest overall acceptability in chicken patties was achieved at Algelica keiskei Koidz dietary fiber levels of 1% and 2%. Chicken patties supplemented with 2% Algelica keiskei Koidz dietary fiber had improved quality characteristics. PMID:26761844
Identification of Ways to Improve Military Construction for Energy-Efficient Facilities.
1987-12-01
inservice . Thus, it is necessary to control techniques, materials, and equip- S ment as part of the Military Construction, Army (MCA) process to ensure...Moreover, USACE often lacks proper test equipment and trained personnel at many construction sites. The 0 result is that acceptance testing often is...on a few diagnostic procedures. USACE quality assurance inspectors would be trained to do the tests. .-. Objectives 0 The overall objective of this
NASA Technical Reports Server (NTRS)
James, John T.
2007-01-01
The toxicological assessments of 2 grab sample canisters (GSCs) and one pair of formaldehyde badges from the Shuttle are reported. Analytical methods have not changed from earlier reports. The recoveries of the 3 surrogates (C-13-acetone, fluorobenzene, and chlorobenzene) from the 2 GSCs averaged 109, 95, and 97%, respectively. Three formaldehyde controls averaged 93% recovery. The Shuttle atmosphere was acceptable for human respiration.
Electron/proton spectrometer certification documentation analyses
NASA Technical Reports Server (NTRS)
Gleeson, P.
1972-01-01
A compilation of analyses generated during the development of the electron-proton spectrometer for the Skylab program is presented. The data documents the analyses required by the electron-proton spectrometer verification plan. The verification plan was generated to satisfy the ancillary hardware requirements of the Apollo Applications program. The certification of the spectrometer requires that various tests, inspections, and analyses be documented, approved, and accepted by reliability and quality control personnel of the spectrometer development program.
1990-02-01
inspections are performed before each formal review of each software life cycle phase. * Required software audits are performed . " The software is acceptable... Audits : Software audits are performed bySQA consistent with thegeneral audit rules and an auditreportis prepared. Software Quality Inspection (SQI...DSD Software Development Method 3-34 DEFINITION OF ACRONYMS Acronym Full Name or Description MACH Methode d’Analyse et de Conception Flierarchisee
Total Quality Leadership as it Applies to the Surface Navy
1990-12-01
with statistical control methods. Dr. Deming opened the eyes of the Japanese. They embraced his ideas and accepted his 14 principles of management shown...move closer to fully embracing Deming’s fourteen principles of management . 3. Shipboard Leadership Compared To TQL Many activities on board Navy ships...The results of the comparison of Deming’s principles of management and the Navalized TQL principles show both similar- ities and differences do appear
Hazlett-Stevens, Holly; Oren, Yelena
2017-06-01
This randomized controlled investigation examined the effectiveness of a self-help bibliotherapy format of the evidence-based mindfulness-based stress reduction (MBSR) intervention. College students seeking stress reduction were randomly assigned to a 10-week MBSR bibliotherapy intervention group (n = 47) or a no-treatment control group (n = 45). Self-report measures were collected at baseline and postintervention. A total of 25 bibliotherapy and 43 control group participants provided final data following the intervention period. Compared to the control group, bibliotherapy participants reported increased mindfulness following the intervention. Significant decreases on measures of depression, anxiety, stress, perceived stress, and anxiety sensitivity also were reported postintervention as well as increased quality of life in physical health, psychological, and environmental domains. No statistically significant group effects were found for social relationships quality of life domain, worry, and experiential avoidance measures. This MBSR workbook may provide an acceptable and effective alternative for motivated individuals seeking to reduce stress, at least for a select group of individuals who are willing and able to sustain participation in the intervention. © 2016 Wiley Periodicals, Inc.
Improving labeling efficiency in automatic quality control of MRSI data.
Pedrosa de Barros, Nuno; McKinley, Richard; Wiest, Roland; Slotboom, Johannes
2017-12-01
To improve the efficiency of the labeling task in automatic quality control of MR spectroscopy imaging data. 28'432 short and long echo time (TE) spectra (1.5 tesla; point resolved spectroscopy (PRESS); repetition time (TR)= 1,500 ms) from 18 different brain tumor patients were labeled by two experts as either accept or reject, depending on their quality. For each spectrum, 47 signal features were extracted. The data was then used to run several simulations and test an active learning approach using uncertainty sampling. The performance of the classifiers was evaluated as a function of the number of patients in the training set, number of spectra in the training set, and a parameter α used to control the level of classification uncertainty required for a new spectrum to be selected for labeling. The results showed that the proposed strategy allows reductions of up to 72.97% for short TE and 62.09% for long TE in the amount of data that needs to be labeled, without significant impact in classification accuracy. Further reductions are possible with significant but minimal impact in performance. Active learning using uncertainty sampling is an effective way to increase the labeling efficiency for training automatic quality control classifiers. Magn Reson Med 78:2399-2405, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jassal, K; Sarkar, B; Mohanti, B
Objective: The study presents the application of a simple concept of statistical process control (SPC) for pre-treatment quality assurance procedure analysis for planar dose measurements performed using 2D-array and a-Si electronic portal imaging device (a-Si EPID). Method: A total of 195 patients of four different anatomical sites: brain (n1=45), head & neck (n2=45), thorax (n3=50) and pelvis (n4=55) were selected for the study. Pre-treatment quality assurance for the clinically acceptable IMRT/VMAT plans was measured with 2D array and a-Si EPID of the accelerator. After the γ-analysis, control charts and the quality index Cpm was evaluated for each cohort. Results: Meanmore » and σ of γ ( 3%/3 mm) were EPID γ %≤1= 99.9% ± 1.15% and array γ %<1 = 99.6% ± 1.06%. Among all plans γ max was consistently lower than for 2D array as compared to a-Si EPID. Fig.1 presents the X-bar control charts for every cohort. Cpm values for a-Si EPID were found to be higher than array, detailed results are presented in table 1. Conclusion: Present study demonstrates the significance of control charts used for quality management purposes in newer radiotherapy clinics. Also, provides a pictorial overview of the clinic performance for the advanced radiotherapy techniques.Higher Cpm values for EPID indicate its higher efficiency than array based measurements.« less
Quality Control of Meteorological Observations
NASA Technical Reports Server (NTRS)
Collins, William; Dee, Dick; Rukhovets, Leonid
1999-01-01
For the first time, a problem of the meteorological observation quality control (QC) was formulated by L.S. Gandin at the Main Geophysical Observatory in the 70's. Later in 1988 L.S. Gandin began adapting his ideas in complex quality control (CQC) to the operational environment at the National Centers for Environmental Prediction. The CQC was first applied by L.S.Gandin and his colleagues to detection and correction of errors in rawinsonde heights and temperatures using a complex of hydrostatic residuals.Later, a full complex of residuals, vertical and horizontal optimal interpolations and baseline checks were added for the checking and correction of a wide range of meteorological variables. some other of Gandin's ideas were applied and substantially developed at other meteorological centers. A new statistical QC was recently implemented in the Goddard Data Assimilation System. The central component of any quality control is a buddy check which is a test of individual suspect observations against available nearby non-suspect observations. A novel feature of this test is that the error variances which are used for QC decision are re-estimated on-line. As a result, the allowed tolerances for suspect observations can depend on local atmospheric conditions. The system is then better able to accept extreme values observed in deep cyclones, jet streams and so on. The basic statements of this adaptive buddy check are described. Some results of the on-line QC including moisture QC are presented.
Preparation and Quality Control of 68Ga-Citrate for PET Applications
Aghanejad, Ayuob; Jalilian, Amir Reza; Ardaneh, Khosro; Bolourinovin, Fatemeh; Yousefnia, Hassan; Samani, Ali Bahrami
2015-01-01
Objective(s): In nuclear medicine studies, gallium-68 (8Ga) citrate has been recently known as a suitable infection agent in positron emission tomography (PET). In this study, by applying an in-house produced 68Ge/68Ga generator, a simple technique for the synthesis and quality control of 68Ga-citrate was introduced; followed by preliminary animal studies. Methods: 68GaCl3 eluted from the generator was studied in terms of quality control factors including radiochemical purity (assessed by HPLC and RTLC), chemical purity (assessed by ICP-EOS), radionuclide purity (evaluated by HPGe), and breakthrough. 68Ga-citrate was prepared from eluted 68GaCl3 and sodium citrate under various reaction conditions. Stability of the complex was evaluated in human serum for 2 h at 370C, followed by biodistribution studies in rats for 120 min. Results: 68Ga-citrate was prepared with acceptable radiochemical purity (>97 ITLC and >98% HPLC), specific activity (4-6 GBq/mM), chemical purity (Sn, Fe<0.3 ppm and Zn<0.2 ppm) within 15 min at 500C. The biodistribution of 68Ga-citrate was consistent with former reports up to 120 minutes. Conclusion: This study demonstrated the possible in-house preparation and quality control of 68Ga-citrate, using a commercially available 68Ge/68Ga generator for PET imaging throughout the country. PMID:27408889
Ghannoum, M. A.; Arthington-Skaggs, B.; Chaturvedi, V.; Espinel-Ingroff, A.; Pfaller, M. A.; Rennie, R.; Rinaldi, M. G.; Walsh, T. J.
2006-01-01
The Clinical and Laboratory Standards Institute (CLSI; formerly National Committee for Clinical Laboratory Standards, or NCCLS) M38-A standard for the susceptibility testing of filamentous fungi does not specifically address the testing of dermatophytes. In 2003, a multicenter study investigated the reproducibility of the microdilution method developed at the Center for Medical Mycology, Cleveland, Ohio, for testing the susceptibility of dermatophytes. Data from that study supported the introduction of this method for testing dermatophytes in the future version of the CLSI M38-A standard. In order for the method to be accepted by CLSI, appropriate quality control isolates needed to be identified. To that end, an interlaboratory study, involving the original six laboratories plus two additional sites, was conducted to evaluate potential candidates for quality control isolates. These candidate strains included five Trichophyton rubrum strains known to have elevated MICs to terbinafine and five Trichophyton mentagrophytes strains. Antifungal agents tested included ciclopirox, fluconazole, griseofulvin, itraconazole, posaconazole, terbinafine, and voriconazole. Based on the data generated, two quality control isolates, one T. rubrum isolate and one T. mentagrophytes isolate, were identified and submitted to the American Type Culture Collection (ATCC) for inclusion as reference strains. Ranges encompassing 95.2 to 97.9% of all data points for all seven drugs were established. PMID:17050812
[Testing of medicinal products produced from pooled plasma].
Unkelbach, U; Hunfeld, A; Breitner-Ruddock, S
2014-10-01
Medicinal products produced from human plasma fall under the administrative batch release procedure of the competent authority. In Germany, this has been carried out since 1995 by the Paul Ehrlich Institute (PEI), the responsible state control agency for blood products. Medicinal products released for the European and national market are tested for quality, efficacy and safety. Experimental testing of the final product and the starting materials, the plasma pools, as well as control of the production documentation guarantee a constantly high product safety. In the 28,000 batches tested since the beginning of the state controlled batch release testing of these blood products at the PEI, there has been no transmission of infectious viruses (HIV, HBV and HCV) to any patient. The batch release has made a contribution to the improvement of product quality. This procedure is still an important tool to ensure safety of blood products. The PEI is integrated in the batch release network of the European Directorate for the Quality of Medicines & Health Care (EDQM) in Strasbourg. Regulations and guidelines for official control authority batch release (OCABR) ensure harmonized procedures for mutual recognition of batch release on the European level. The EU certificates and German national certificates are requested and accepted in over 70 countries worldwide. Experimental testing in the EU and the requisite certificates have developed into a seal of quality for the world market.
Casey, Lori J; Van Rooy, Kimberly M; Sutherland, Stephanie J; Jenkins, Sarah M; Rosedahl, Jordan K; Wood, Nadia G; Ebbert, Jon O; Lopez-Jimenez, Francisco; Egginton, Jason S; Sim, Leslie A; Clark, Matthew M
2018-03-29
Yoga is increasing in popularity in the United States and across the globe. However, most yoga programs are provided outside the worksite; although many companies offer worksite wellness programs, at present there is limited documentation regarding the potential benefits of participating in a worksite yoga program. Therefore, the purpose of this project was to examine the potential effect of a worksite yoga program on self-acceptance, quality of life, and perceived stress. A prospective cohort pilot study that examined a structured worksite yoga program was designed and tailored to individuals new to yoga. The 8-week Yoga Foundations program was conducted at an academic medical center's worksite wellness center with 86 subjects. Outcome measures were the 36-item Self-Acceptance Scale; a six-item quality-of-life measure that assesses overall, social, mental, physical, emotional, and spiritual well-being; and the ten-item Perceived Stress Scale. Participants demonstrated significant improvement in their overall self-acceptance ( p < 0.001), quality of life ( p < 0.001), and perceived stress ( p ≤ 0.001) levels. They also highly rated the yoga instructors and the weekly format of the program. Participation in a Yoga Foundations program was associated with improvements in self-acceptance, quality of life and stress levels in worksite wellness center members. Future studies should use randomized designs and examine other wellness domains to learn more about the potential benefits of worksite yoga programs.
Daoud, Salima; Chakroun-Feki, Nozha; Sellami, Afifa; Ammar-Keskes, Leila; Rebai, Tarek
2016-01-01
Semen analysis is a key part of male infertility investigation. The necessity of quality management implementation in the andrology laboratory has been recognized in order to ensure the reliability of its results. The aim of this study was to evaluate intra- and inter-individual variability in the assessment of semen parameters in our laboratory through a quality control programme. Four participants from the laboratory with different experience levels have participated in this study. Semen samples of varying quality were assessed for sperm motility, concentration and morphology and the results were used to evaluate inter-participant variability. In addition, replicates of each semen sample were analyzed to determine intra-individual variability for semen parameters analysis. The average values of inter-participant coefficients of variation for sperm motility, concentration and morphology were 12.8%, 19.8% and 48.9% respectively. The mean intra-participant coefficients of variation were, respectively, 6.9%, 12.3% and 42.7% for sperm motility, concentration and morphology. Despite some random errors of under- or overestimation, the overall results remained within the limits of acceptability for all participants. Sperm morphology assessment was particularly influenced by the participant's level of experience. The present data emphasize the need for appropriate training of the laboratory staff and for regular participation in internal quality control programmes in order to improve the reliability of laboratory results.
Exploring E-Learning Acceptance among University Students in Thailand: A National Survey
ERIC Educational Resources Information Center
Teo, Timothy; Ruangrit, Nammon; Khlaisang, Jintavee; Thammetar, Thapanee; Sunphakitjumnong, Kobkul
2014-01-01
This study surveys the e-learning acceptance of university students in Thailand. One thousand nine hundred and eighty-one (1,981) participants completed the E-Learning Acceptance Measure (Teo, 2010) which measures three constructs that predict e-learning acceptance (tutor quality, perceived usefulness, and facilitating conditions). Data analysis…
Pedley, Rebecca; Lovell, Karina; Bee, Penny; Bradshaw, Tim; Gellatly, Judith; Ward, Kate; Woodham, Adrine; Wearden, Alison
2018-04-25
The adverse impact of unhealthy lifestyle choices and the prescription of antipsychotic medications contribute to weight gain, poor cardiovascular health and reduced life expectancy for people with psychosis. The present study aimed to explore the acceptability and perceived outcomes of a lifestyle intervention designed to prevent or reduce weight gain in people with first-episode psychosis. This was a qualitative study using a data-driven approach. People recovering from first-episode psychosis recruited from UK early intervention services and taking part in the active arm of a randomised controlled trial of a lifestyle intervention (the InterACT trial), were interviewed using a semi-structured interview schedule. Interviews were transcribed verbatim and analysed using Framework Analysis. Participants valued the collaborative and individualised approach taken by the intervention deliverers, and formed high quality relationships with them. Aspects of the intervention that were positively appraised included goal setting, social opportunities, and progress monitoring. Benefits of the intervention, including increased levels of exercise; improved diet and physical health; increased psychological wellbeing (e.g. confidence, self-esteem); and improved social relationships, were identified by participants, independent of actual weight loss. Future interventions should ensure that workers have the skills to form high quality relationships with users, and to individualise the intervention according to users' needs and preferences. Future trials that test healthy living interventions should consider supplementing physical outcome measures with wider psychosocial outcome assessments, in particular social relationship quality, psychological wellbeing, self-esteem and self-efficacy. Current Controlled Trials: ISRCTN22581937 . Date of registration: 27 October 2010 (retrospectively registered).
de Vries, Nienke M; van Ravensberg, C Dorine; Hobbelen, Johannes S M; van der Wees, Philip J; Olde Rikkert, Marcel G M; Staal, J Bart; Nijhuis-van der Sanden, Maria W G
2015-01-01
Despite the positive effects of physical activity on numerous aspects of health, many older adults remain sedentary even after participating in physical activity interventions. Standardized exercise programs do not necessarily bring about the behavioral change that is necessary. Therefore, a patient-centered approach is needed. The purpose of this study was to develop and assess the acceptability and potential effectiveness of the Coach2Move strategy; a physical therapy (PT) approach aimed at improving the long-term level of physical activity in mobility-limited older adults. The Coach2Move strategy was developed on the basis of 2 systematic literature studies and expert consultations. Multiple focus group meetings and a Delphi procedure were organized to gain consensus on the Coach2Move strategy. Acceptability and potential effectiveness were studied in a pilot study with a pre-/postdesign in which 2 physical therapists and 12 patients participated. To assess acceptability, patients were interviewed, discussion were held with the involved physical therapists was held, and health records were studied. Potential effectiveness was tested measuring the level of physical activity, frailty, quality of life, and mobility before and after treatment. On the basis of the literature study and expert consultations, an algorithm based on the Hypothesis Oriented Algorithm for Clinicians Part II was developed: the Coach2Move approach. Key elements of the Coach2Move approach include an extensive intake using motivational interviewing, clinical reasoning, coaching to increase physical activity and self-management, focusing on meaningful activities, and working according to 3 patient-tailored intervention profiles with a predefined number of sessions. The pilot study showed high appraisal of the strategy by both physical therapists and patients. Moreover, a potential effect on the level of physical activity, frailty, quality of life, and mobility was observed. Because the pilot study was not randomized or controlled and included a small sample, no conclusions can be drawn about the effectiveness of the Coach2Move strategy. However, all suggestions made in this study were implemented in an ongoing, randomized controlled trial in which the Coach2Move strategy will be compared to usual care PT. In conclusion, the Coach2Move strategy can be considered acceptable in PT practice and showed potential benefits. The results on the (cost-)effectiveness of this strategy based on a large, randomized, controlled trial are expected in 2014.
Development of the sonic pump levitator
NASA Technical Reports Server (NTRS)
Dunn, S. A.
1985-01-01
The process and mechanism involved in producing glass microballoons (GMBs) of acceptable quality for laser triggered inertial fusion through use of glass jet levitation and manipulation are considered. The gas jet levitation device, called sonic pumps, provides positioning by timely and appropriate application of gas mementum from one or more of six sonic pumps which are arranged orthogonally in opposed pairs about the levitation region and are activated by an electrooptical, computer controlled, feedback system. The levitation device was fabricated and its associated control systems were assembled into a package and tested in reduced gravity flight regime of the NASA KC-135 aircraft.
Sharma, R R; Pal, R K; Singh, D; Samuel, D V K; Sethi, S; Kumar, A
2013-06-01
Effect of heat shrinkable films on shelf life and quality of apples under ambient conditions was studied. Fully mature Royal Delicious apples (starch index 2.5 on 4.0 point scale) were either shrink-wrapped in 3 heat shrinkable films like Cryovac (9 μ), polyolefin (13 μ) and LDPE (25 μ) or were not wrapped at all (control) and then stored at ambient conditions (22-28°C and 52-68% RH). Observations on physiological loss in weight (PLW), decay loss, firmness, juice recovery, total soluble solids (TSS), acidity, ascorbic acid content and overall sensory quality were recorded immediately before packing, and after packing at weekly intervals. Best results were obtained with Cryovac (9 μ) films, which exhibited least PLW (2.3%) and decay loss (2.8%) and higher juice recovery (65.2%) and TSS (16.4%) over other films or control. Apples wrapped in Cryovac films also had higher overall sensory acceptability (8.3 out of 9) over other films or control. These studies indicated that apples could be very well packed in Cryovac heat shrinkable films for about 35 days with least PLW or decay loss, and without any adverse effect on fruit quality.
Zheng, Ajuan; Zhang, Lihui; Wang, Shaojin
2017-05-16
Radio frequency (RF) heating has been proposed and tested to achieve a required anti-fungal efficacy on various food samples due to its advantage of deeper penetration depth and better heating uniformity. The purpose of this study was to validate applications of RF treatments for controlling Aspergillus parasiticus in corn while maintaining product quality. A pilot-scale, 27.12MHz, 6kW RF heating system together with hot air heating was used to rapidly pasteurize 3.0kg corn samples. Results showed that the pasteurizing effect of RF heating on Aspergillus parasiticus increased with increasing heating temperature and holding time, and RF heating at 70°C holding in hot air for at least 12min resulted in 5-6 log reduction of Aspergillus parasiticus in corn samples with the moisture content of 15.0% w.b. Furthermore, thermal resistance of Aspergillus parasiticus decreased with increasing moisture content (MC) of corn samples. Quality (MC, water activity - a w , protein, starch, ash, fat, fatty acid, color, electrical conductivity and germination rate) of RF treated corn met the required quality standard used in cereal industry. Therefore, RF treatments can provide an effective and rapid heating method to control Aspergillus parasiticus and maintain acceptable corn quality. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Miwa, Shotaro; Kage, Hiroshi; Hirai, Takashi; Sumi, Kazuhiko
We propose a probabilistic face recognition algorithm for Access Control System(ACS)s. Comparing with existing ACSs using low cost IC-cards, face recognition has advantages in usability and security that it doesn't require people to hold cards over scanners and doesn't accept imposters with authorized cards. Therefore face recognition attracts more interests in security markets than IC-cards. But in security markets where low cost ACSs exist, price competition is important, and there is a limitation on the quality of available cameras and image control. Therefore ACSs using face recognition are required to handle much lower quality images, such as defocused and poor gain-controlled images than high security systems, such as immigration control. To tackle with such image quality problems we developed a face recognition algorithm based on a probabilistic model which combines a variety of image-difference features trained by Real AdaBoost with their prior probability distributions. It enables to evaluate and utilize only reliable features among trained ones during each authentication, and achieve high recognition performance rates. The field evaluation using a pseudo Access Control System installed in our office shows that the proposed system achieves a constant high recognition performance rate independent on face image qualities, that is about four times lower EER (Equal Error Rate) under a variety of image conditions than one without any prior probability distributions. On the other hand using image difference features without any prior probabilities are sensitive to image qualities. We also evaluated PCA, and it has worse, but constant performance rates because of its general optimization on overall data. Comparing with PCA, Real AdaBoost without any prior distribution performs twice better under good image conditions, but degrades to a performance as good as PCA under poor image conditions.
Imai, Hissei; Tajika, Aran; Chen, Peiyao; Pompoli, Alessandro; Furukawa, Toshi A
2016-10-12
Panic disorder is common and deleterious to mental well-being. Psychological therapies and pharmacological interventions are both used as treatments for panic disorder with and without agoraphobia. However, there are no up-to-date reviews on the comparative efficacy and acceptability of the two treatment modalities, and such a review is necessary for improved treatment planning for this disorder. To assess the efficacy and acceptability of psychological therapies versus pharmacological interventions for panic disorder, with or without agoraphobia, in adults. We searched the Cochrane Common Mental Disorders Group Specialised Register on 11 September 2015. This register contains reports of relevant randomised controlled trials from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (1950 to present), Embase (1974 to present), and PsycINFO (1967 to present). We cross-checked reference lists of relevant papers and systematic reviews. We did not apply any restrictions on date, language, or publication status. We included all randomised controlled trials comparing psychological therapies with pharmacological interventions for panic disorder with or without agoraphobia as diagnosed by operationalised criteria in adults. Two review authors independently extracted data and resolved any disagreements in consultation with a third review author. For dichotomous data, we calculated risk ratios (RR) with 95% confidence intervals (CI). We analysed continuous data using standardised mean differences (with 95% CI). We used the random-effects model throughout. We included 16 studies with a total of 966 participants in the present review. Eight of the studies were conducted in Europe, four in the USA, two in the Middle East, and one in Southeast Asia.None of the studies reported long-term remission/response (long term being six months or longer from treatment commencement).There was no evidence of a difference between psychological therapies and selective serotonin reuptake inhibitors (SSRIs) in terms of short-term remission (RR 0.85, 95% CI 0.62 to 1.17; 6 studies; 334 participants) or short-term response (RR 0.97, 95% CI 0.51 to 1.86; 5 studies; 277 participants) (very low-quality evidence), and no evidence of a difference between psychological therapies and SSRIs in treatment acceptability as measured using dropouts for any reason (RR 1.33, 95% CI 0.80 to 2.22; 6 studies; 334 participants; low-quality evidence).There was no evidence of a difference between psychological therapies and tricyclic antidepressants in terms of short-term remission (RR 0.82, 95% CI 0.62 to 1.09; 3 studies; 229 participants), short-term response (RR 0.75, 95% CI 0.51 to 1.10; 4 studies; 270 participants), or dropouts for any reason (RR 0.83, 95% CI 0.53 to 1.30; 5 studies; 430 participants) (low-quality evidence).There was no evidence of a difference between psychological therapies and other antidepressants in terms of short-term remission (RR 0.90, 95% CI 0.48 to 1.67; 3 studies; 135 participants; very low-quality evidence) and evidence that psychological therapies did not significantly increase or decrease the short-term response over other antidepressants (RR 0.96, 95% CI 0.67 to 1.37; 3 studies; 128 participants) or dropouts for any reason (RR 1.55, 95% CI 0.91 to 2.65; 3 studies; 180 participants) (low-quality evidence).There was no evidence of a difference between psychological therapies and benzodiazepines in terms of short-term remission (RR 1.08, 95% CI 0.70 to 1.65; 3 studies; 95 participants), short-term response (RR 1.58, 95% CI 0.70 to 3.58; 2 studies; 69 participants), or dropouts for any reason (RR 1.12, 95% CI 0.54 to 2.36; 3 studies; 116 participants) (very low-quality evidence).There was no evidence of a difference between psychological therapies and either antidepressant alone or antidepressants plus benzodiazepines in terms of short-term remission (RR 0.86, 95% CI 0.71 to 1.05; 11 studies; 663 participants) and short-term response (RR 0.95, 95% CI 0.76 to 1.18; 12 studies; 800 participants) (low-quality evidence), and there was no evidence of a difference between psychological therapies and either antidepressants alone or antidepressants plus benzodiazepines in terms of treatment acceptability as measured by dropouts for any reason (RR 1.08, 95% CI 0.77 to 1.51; 13 studies; 909 participants; very low-quality evidence). The risk of selection bias and reporting bias was largely unclear. Preplanned subgroup and sensitivity analyses limited to trials with longer-term, quality-controlled, or individual psychological therapies suggested that antidepressants might be more effective than psychological therapies for some outcomes.There were no data to contribute to a comparison between psychological therapies and serotonin-norepinephrine reuptake inhibitors (SNRIs) and subsequent adverse effects. The evidence in this review was often imprecise. The superiority of either therapy over the other is uncertain due to the low and very low quality of the evidence with regard to short-term efficacy and treatment acceptability, and no data were available regarding adverse effects.The sensitivity analysis and investigation of the sources of heterogeneity indicated three possible influential factors: quality control of psychological therapies, the length of intervention, and the individual modality of psychological therapies.Future studies should examine the long-term effects after intervention or treatment continuation and should provide information on risk of bias, especially with regard to selection and reporting biases.
Gardiner, Emily; Iarocci, Grace
2014-05-01
With growing numbers of individuals with autism spectrum disorder (ASD) entering post-secondary institutions, strategies are needed to facilitate the social integration of these students. The goal of this study was to examine the role of various factors in university students’ acceptance of, and intention to volunteer with, a peer with ASD. Both contact quantity and quality emerged as significant predictors of acceptance; however, for those who had experienced direct contact with individuals with ASD, only perceived quality emerged as significant. Moreover, acceptance played a significant role in participants’ likelihood of signing up to volunteer. These findings point to the central role that positive experiences play in attitude formation for this population.
Torri, Luisa; Frati, Alessandra; Ninfali, Paolino; Mantegna, Stefano; Cravotto, Giancarlo; Morini, Gabriella
2017-06-01
The demand for zero and reduced-sugar food products containing cocoa is expanding continuously. The present study was designed to evaluate the feasibility of producing high-quality chocolate sweetened with a crude extract of Stevia rebaudiana (Bertoni) prepared by a green microwave-assisted water-steam extraction procedure. Seven approximately isosweet chocolate formulations were developed, mixing cocoa paste, sucrose, commercial stevioside, crude green extract and maltitol in different proportions. All samples were analyzed for the determination of polyphenol and flavonoid content, antioxidant activity, and sensory acceptability. The use of a crude stevia extract allowed low-sugar, high-quality chocolates to be obtained that were also acceptable by consumers and had a significant increased antioxidant activity. Moreover, consumers' segmentation revealed a cluster of consumers showing the same overall liking for the sample with 50% sucrose replaced by the stevia crude extract as that obtained with the commercial stevioside and the control sample (without sucrose replacement). The results provide information that can contribute to promoting the development of sweet food products, with advantages in terms of an improved nutritional value (reduced sugar content and increased antioxidant activity) and a reduced impact of the production process on the environment. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
Rocha, C P; Croci, C S; Caria, P H F
2013-11-01
The objective of this systematic review was to find sufficient evidence to deny or accept the association between the head and cervical posture and temporomandibular disorders (TMDs), and thus assist health professionals in the evaluation and treatment of patients with TMDs. A search was conducted through all publications written in English about this topic using the databases from Medline, ISI Web of Science, EMBASE, PubMed and Lilacs. The abstracts that fulfilled the initial guideline were retrieved and evaluated to ensure they met the inclusion criteria. To assess the methodological quality of the studies, we developed a questionnaire considering the following criteria: participant's eligibility, control group, diagnosis of TMDs, posture diagnosis and randomisation. Twenty-two studies were selected as potential studies based on their abstracts. Only seventeen studies actually fulfilled the inclusion criteria. The search provided information about the methodological quality of the studies, in which several methodological defects were found. The evidence presented in this systematic review shows that the relation between TMDs and the head and neck posture is still controversial and unclear. The insufficient number of articles considered of excellent methodological quality is a factor that hinders the acceptance or denial of this association. © 2013 John Wiley & Sons Ltd.
48 CFR 446.370 - Inspection and acceptance.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Inspection and acceptance. 446.370 Section 446.370 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE CONTRACT MANAGEMENT QUALITY ASSURANCE Contract Clauses 446.370 Inspection and acceptance. The Contracting Officer...
Long-Term Ecological Monitoring Field Sampling Plan for 2007
DOE Office of Scientific and Technical Information (OSTI.GOV)
T. Haney
2007-07-31
This field sampling plan describes the field investigations planned for the Long-Term Ecological Monitoring Project at the Idaho National Laboratory Site in 2007. This plan and the Quality Assurance Project Plan for Waste Area Groups 1, 2, 3, 4, 5, 6, 7, 10, and Removal Actions constitute the sampling and analysis plan supporting long-term ecological monitoring sampling in 2007. The data collected under this plan will become part of the long-term ecological monitoring data set that is being collected annually. The data will be used t determine the requirements for the subsequent long-term ecological monitoring. This plan guides the 2007more » investigations, including sampling, quality assurance, quality control, analytical procedures, and data management. As such, this plan will help to ensure that the resulting monitoring data will be scientifically valid, defensible, and of known and acceptable quality.« less
The role of point of care ultrasound in prehospital critical care: a systematic review.
Bøtker, Morten Thingemann; Jacobsen, Lars; Rudolph, Søren Steemann; Knudsen, Lars
2018-06-26
In 2011, the role of Point of Care Ultrasound (POCUS) was defined as one of the top five research priorities in physician-provided prehospital critical care and future research topics were proposed; the feasibility of prehospital POCUS, changes in patient management induced by POCUS and education of providers. This systematic review aimed to assess these three topics by including studies examining all kinds of prehospital patients undergoing all kinds of prehospital POCUS examinations and studies examining any kind of POCUS education in prehospital critical care providers. By a systematic literature search in MEDLINE, EMBASE, and Cochrane databases, we identified and screened titles and abstracts of 3264 studies published from 2012 to 2017. Of these, 65 studies were read in full-text for assessment of eligibility and 27 studies were ultimately included and assessed for quality by SIGN-50 checklists. No studies compared patient outcome with and without prehospital POCUS. Four studies of acceptable quality demonstrated feasibility and changes in patient management in trauma. Two studies of acceptable quality demonstrated feasibility and changes in patient management in breathing difficulties. Four studies of acceptable quality demonstrated feasibility, outcome prediction and changes in patient management in cardiac arrest, but also that POCUS may prolong pauses in compressions. Two studies of acceptable quality demonstrated that short (few hours) teaching sessions are sufficient for obtaining simple interpretation skills, but not image acquisition skills. Three studies of acceptable quality demonstrated that longer one- or two-day courses including hands-on training are sufficient for learning simple, but not advanced, image acquisition skills. Three studies of acceptable quality demonstrated that systematic educational programs including supervised examinations are sufficient for learning advanced image acquisition skills in healthy volunteers, but that more than 50 clinical examinations are required for expertise in a clinical setting. Prehospital POCUS is feasible and changes patient management in trauma, breathing difficulties and cardiac arrest, but it is unknown if this improves outcome. Expertise in POCUS requires extensive training by a combination of theory, hands-on training and a substantial amount of clinical examinations - a large part of these needs to be supervised.
NASA Technical Reports Server (NTRS)
Kondoz, A. M.; Evans, B. G.
1993-01-01
In the last decade, low bit rate speech coding research has received much attention resulting in newly developed, good quality, speech coders operating at as low as 4.8 Kb/s. Although speech quality at around 8 Kb/s is acceptable for a wide variety of applications, at 4.8 Kb/s more improvements in quality are necessary to make it acceptable to the majority of applications and users. In addition to the required low bit rate with acceptable speech quality, other facilities such as integrated digital echo cancellation and voice activity detection are now becoming necessary to provide a cost effective and compact solution. In this paper we describe a CELP speech coder with integrated echo canceller and a voice activity detector all of which have been implemented on a single DSP32C with 32 KBytes of SRAM. The quality of CELP coded speech has been improved significantly by a new codebook implementation which also simplifies the encoder/decoder complexity making room for the integration of a 64-tap echo canceller together with a voice activity detector.
Development and evaluation of a quality score for abstracts
Timmer, Antje; Sutherland, Lloyd R; Hilsden, Robert J
2003-01-01
Background The evaluation of abstracts for scientific meetings has been shown to suffer from poor inter observer reliability. A measure was developed to assess the formal quality of abstract submissions in a standardized way. Methods Item selection was based on scoring systems for full reports, taking into account published guidelines for structured abstracts. Interrater agreement was examined using a random sample of submissions to the American Gastroenterological Association, stratified for research type (n = 100, 1992–1995). For construct validity, the association of formal quality with acceptance for presentation was examined. A questionnaire to expert reviewers evaluated sensibility items, such as ease of use and comprehensiveness. Results The index comprised 19 items. The summary quality scores showed good interrater agreement (intra class coefficient 0.60 – 0.81). Good abstract quality was associated with abstract acceptance for presentation at the meeting. The instrument was found to be acceptable by expert reviewers. Conclusion A quality index was developed for the evaluation of scientific meeting abstracts which was shown to be reliable, valid and useful. PMID:12581457
Quality, microstructure, biochemical and immunochemical characteristics of hypoallergenic pasta.
Susanna, S; Prabhasankar, P
2012-08-01
Celiac disease is an immune-mediated enteropathy, characterized by lifelong intolerance to gluten in genetically susceptible individuals. This study aims to develop hypoallergenic pasta using blends of Triticum durum semolina, 40% of other non-wheat flours and additives. Formulated pasta samples were evaluated for product quality characteristics and also subjected to biochemical analysis. Results showed that cooking loss ranged from 6.9% to 7.4%, which were within the acceptable range of 8%. Color change was low and in vitro protein digestibility of the pasta was found to be insignificant. Pasting characteristics of the hypoallergenic flour showed the increased peak viscosity and decreased gelatinization temperature. The scanning electron microscopy results demonstrated less-affected microstructure of gluten network. Texture profile analysis and descriptive sensory analysis revealed that optimized hypoallergenic pasta with xanthan gum as additive was acceptable and comparable with control. SDS-PAGE pattern showed distinct protein profile and decreased intensity, which was supported by Dot-Blot. In conclusion, the hypoallergenic pasta prepared by replacing T durum flour by 40% of other non-gluten flours could be useful for celiac patients because of its low antigenic activity.
NASA Technical Reports Server (NTRS)
Grantham, W. D.; Deal, P. L.; Keyser, G. L., Jr.; Smith, P. M.
1983-01-01
A six degree-of-freedom, ground-based simulator study was conducted to evaluate the low speed flight characteristics of a twin fuselage cargo transport airplane and to compare these characteristics with those of a large, single fuselage (reference) transport configuration which was similar to the Lockheed C-5C airplane. The primary piloting task was the approach and landing. The results indicated that in order to achieve "acceptable' low speed handling qualities on the twin fuselage concept, considerable stability and control augmentation was required, and although the augmented airplane could be landed safely under adverse conditions, the roll performance of the aircraft had to be improved appreciably before the handling qualities were rated as being "satisfactory.' These ground-based simulation results indicated that a value of t sub phi = 30 (time required to bank 30 deg) less than 6 sec should result in "acceptable' roll response characteristics, and when t sub phi = 30 is less than 3.8 sec, "satisfactory' roll response should be attainable on such large and unusually configured aircraft as the subject twin fuselage cargo transport concept.
Code of Federal Regulations, 2014 CFR
2014-07-01
... level and passing and failing criteria for selective enforcement audits. 90.510 Section 90.510....510 Compliance with acceptable quality level and passing and failing criteria for selective... failed engine is an engine whose final test results pursuant to § 90.509(b), for one or more of the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... level and passing and failing criteria for Selective Enforcement Audits. 86.610-98 Section 86.610-98... and passing and failing criteria for Selective Enforcement Audits. (a) The prescribed acceptable quality level is 40 percent. (b) A failed vehicle is one whose final deteriorated test results pursuant to...
Code of Federal Regulations, 2013 CFR
2013-07-01
... level and passing and failing criteria for selective enforcement audits. 90.510 Section 90.510....510 Compliance with acceptable quality level and passing and failing criteria for selective... failed engine is an engine whose final test results pursuant to § 90.509(b), for one or more of the...
Carrying capacity as "informed judgment": The values of science and the science of values
Robert E. Manning
2001-01-01
Contemporary carrying capacity frameworks, such as Limits of Acceptable Change and Visitor Experience and Resource Protection, rely on formulation of standards of quality, which are defined as minimum acceptable resource and social conditions in parks and wilderness. Formulation of standards of quality involves elements of both science and values, and both of these...
ERIC Educational Resources Information Center
Salajan, Florin D.; Welch, Anita G.; Ray, Chris M.; Peterson, Claudette
2015-01-01
This study's primary investigation is the impact of "peer influence" and "perceived quality of teaching" on faculty members' usage of web-based learning management systems within the Technology Acceptance Model (TAM) framework. These factors are entered into an extended TAM as external variables impacting on the core constructs…
Tao, Donghua
2008-01-01
This study extended the Technology Acceptance Model (TAM) by examining the roles of two aspects of e-resource characteristics, namely, information quality and system quality, in predicting public health students’ intention to use e-resources for completing research paper assignments. Both focus groups and a questionnaire were used to collect data. Descriptive analysis, data screening, and Structural Equation Modeling (SEM) techniques were used for data analysis. The study found that perceived usefulness played a major role in determining students’ intention to use e-resources. Perceived usefulness and perceived ease of use fully mediated the impact that information quality and system quality had on behavior intention. The research model enriches the existing technology acceptance literature by extending TAM. Representing two aspects of e-resource characteristics provides greater explanatory information for diagnosing problems of system design, development, and implementation. PMID:18999300
Tao, Donghua
2008-11-06
This study extended the Technology Acceptance Model (TAM) by examining the roles of two aspects of e-resource characteristics, namely, information quality and system quality, in predicting public health students' intention to use e-resources for completing research paper assignments. Both focus groups and a questionnaire were used to collect data. Descriptive analysis, data screening, and Structural Equation Modeling (SEM) techniques were used for data analysis. The study found that perceived usefulness played a major role in determining students' intention to use e-resources. Perceived usefulness and perceived ease of use fully mediated the impact that information quality and system quality had on behavior intention. The research model enriches the existing technology acceptance literature by extending TAM. Representing two aspects of e-resource characteristics provides greater explanatory information for diagnosing problems of system design, development, and implementation.
Determinants of user satisfaction with a Clinical Information System.
Palm, Jean-Marc; Colombet, Isabelle; Sicotte, Claude; Degoulet, Patrice
2006-01-01
Clinical Information Systems (CIS) implementation has faced user resistance. Consequently, we aimed to assess the acceptability of an integrated CIS. We designed an electronic survey instrument from two theoretical models (Delone and McLean, and Technology Acceptance Model). Dimensions hypothesized to be determinant of user satisfaction were: user characteristics, CIS use, quality, usefulness, and service quality. The questionnaire was administered to physicians, nurses and medical secretaries of the Georges Pompidou university Hospital (HEGP) in Paris. Answers were obtained from 324 users (93 physicians, 174 nurses, and 57 secretaries). Cronbach's alpha coefficients showed a correct reliability within each dimension. Secretaries and nurses were more satisfied with the CIS than physicians. Except for CIS use, after adjustment for confounders, female gender, perceived CIS quality, usefulness, and service quality were strongly correlated with user satisfaction. This study reinforces the necessity of several models and dimensions to evaluate the acceptability of a complex CIS, with a specific approach for different user profiles.
Van Bost, Gunther; Van Damme, Stefaan; Crombez, Geert
2017-01-01
An acquired brain injury (ABI) is a challenge for an individual's quality of life (QOL). In several chronic illnesses acceptance has been found to be associated with a better health-related quality of life. This study investigated whether this relationship is also found in patients with ABI. We also explored the impact of the perceived ability to live according to one's own values (life-values-match). A total of 68 individuals (18-65 years of age) with an acquired brain injury completed a battery of questionnaires. The relations between health-related QOL (SF-36) and disease specific QOL (EBIQ; European Brain Injury Questionnaire), and personal values (Schwartz Values Inventory) and acceptance (ICQ; Illness Cognitions Questionnaire) were investigated. An additional question measured the life-values-match. Rehabilitation professionals reported the extent of impairment involved. Acceptance was positively associated with mental aspects of health-related QOL and the EBIQ Core Scale, after demographic variables and the extent of impairment were introduced in the regression. In a post hoc analysis we found that the life-values-match mediated the relationship between acceptance and mental aspects of QOL. In patients with an ABI, promoting acceptance may be useful to protect QOL. Strengthening the life-values-match may be a way to accomplish this.
Autologous tolerogenic dendritic cells for rheumatoid and inflammatory arthritis
Bell, G M; Anderson, A E; Diboll, J; Reece, R; Eltherington, O; Harry, R A; Fouweather, T; MacDonald, C; Chadwick, T; McColl, E; Dunn, J; Dickinson, A M; Hilkens, C M U; Isaacs, John D
2017-01-01
Objectives To assess the safety of intra-articular (IA) autologous tolerogenic dendritic cells (tolDC) in patients with inflammatory arthritis and an inflamed knee; to assess the feasibility and acceptability of the approach and to assess potential effects on local and systemic disease activities. Methods An unblinded, randomised, controlled, dose escalation Phase I trial. TolDC were differentiated from CD14+ monocytes and loaded with autologous synovial fluid as a source of autoantigens. Cohorts of three participants received 1×106, 3×106 or 10×106 tolDC arthroscopically following saline irrigation of an inflamed (target) knee. Control participants received saline irrigation only. Primary outcome was flare of disease in the target knee within 5 days of treatment. Feasibility was assessed by successful tolDC manufacture and acceptability via patient questionnaire. Potential effects on disease activity were assessed by arthroscopic synovitis score, disease activity score (DAS)28 and Health Assessment Questionnaire (HAQ). Immunomodulatory effects were sought in peripheral blood. Results There were no target knee flares within 5 days of treatment. At day 14, arthroscopic synovitis was present in all participants except for one who received 10×106 tolDC; a further participant in this cohort declined day 14 arthroscopy because symptoms had remitted; both remained stable throughout 91 days of observation. There were no trends in DAS28 or HAQ score or consistent immunomodulatory effects in peripheral blood. 9 of 10 manufactured products met quality control release criteria; acceptability of the protocol by participants was high. Conclusion IA tolDC therapy appears safe, feasible and acceptable. Knee symptoms stabilised in two patients who received 10×106 tolDC but no systemic clinical or immunomodulatory effects were detectable. Trial registration number NCT01352858. PMID:27117700
Impact of soybean aging conditions on tofu sensory characteristics and acceptance.
Kamizake, Neide Kiyoko Kondo; Silva, Lilian Catarini Pereira; Prudencio, Sandra Helena
2018-02-01
Tofu from aged soybeans is of poor quality, mainly with respect to texture. Texture defects described in the literature are contradictory. No study has investigated all sensory properties simultaneously. The objective of the present study was to evaluate the effect of soybean aging conditions [natural: ambient temperature and RH, 18 months, and accelerated: 30 °C, 84% relative humidity (RH), 6 months] on all of the sensory characteristics and the acceptance of tofu. Texture and color were also evaluated via an instrumental method. The control condition was -20 °C and 47% RH. Coodetec 214 and BRS 267 cultivars were studied. The effect of soybean accelerated aging on tofu sensory characteristics and acceptance was more pronounced compared to the natural condition. The two cultivars had a similar behavior. Tofu control exhibited a light, uniform and bright color, cohesive appearance, sweet aroma and flavor, as well as a firm and elastic texture. Tofu made from both aged cultivars showed a gray color with dark spots, a rough appearance, fermented aroma, rancid flavor, an astringent and bitter taste, a fracturable texture and adherence to the oral cavity after chewing. These characteristics of tofu from aged soybeans implied a low acceptance by consumers. Tofu from natural and accelerated aged soybeans has sensory attributes of appearance, as well as aroma, flavor and damaged texture, that are unacceptable by consumers. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malkoske, Kyle; Nielsen, Michelle; Brown, Erika
A close partnership between the Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) has resulted in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. The framework includes consolidation of existing guidelines and/or literature by expert reviewers, structured stages of public review, external field-testing and ratification by COMP. The adopted framework for the development and maintenance of themore » TQCs ensures the guidelines incorporate input from the medical physics community during development, measures the workload required to perform the QC tests outlined in each TQC, and remain relevant (i.e. “living documents”) through subsequent planned reviews and updates. This presentation will show the Multi-Leaf Linear Accelerator document as an example of how feedback and cross-national work to achieve a robust guidance document. During field-testing, each technology was tested at multiple centres in a variety of clinic environments. As part of the defined feedback, workload data was captured. This lead to average time associated with testing as defined in each TQC document. As a result, for a medium-sized centre comprising 6 linear accelerators and a comprehensive brachytherapy program, we evaluate the physics workload to 1.5 full-time equivalent physicist per year to complete all QC tests listed in this suite.« less
Radiation protection program for early detection of breast cancer in a mammography facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mariana, Villagomez Casimiro, E-mail: marjim10-66@ciencias.unam.mx, E-mail: cesar@fisica.unam.mx; Cesar, Ruiz Trejo, E-mail: marjim10-66@ciencias.unam.mx, E-mail: cesar@fisica.unam.mx; Ruby, Espejo Fonseca
Mammography is the best tool for early detection of Breast Cancer. In this diagnostic radiology modality it is necessary to establish the criteria to ensure the proper use and operation of the equipment used to obtain mammographic images in order to contribute to the safe use of ionizing radiation. The aim of the work was to implement at FUCAM-AC the radiation protection program which must be established for patients and radiation workers according to Mexican standards [1–4]. To achieve this goal, radiation protection and quality control manuals were elaborated [5]. Furthermore, a quality control program (QCP) in the mammography systemsmore » (analog/digital), darkroom included, has been implemented. Daily sensitometry, non-variability of the image quality, visualizing artifacts, revision of the equipment mechanical stability, compression force and analysis of repetition studies are some of the QCP routine tests that must be performed by radiological technicians of this institution as a set of actions to ensure the protection of patients. Image quality and patients dose assessment were performed on 4 analog equipment installed in 2 mobile units. In relation to dose assessment, all equipment passed the acceptance criteria (<3 mGy per projection). The image quality test showed that most images (70%)– presented artifacts. A brief summary of the results of quality control tests applied to the equipment and film processor are presented. To maintain an adequate level of quality and safety at FUCAM-AC is necessary that the proposed radiation protection program in this work is applied.« less
Quality control in public participation assessments of water quality: the OPAL Water Survey.
Rose, N L; Turner, S D; Goldsmith, B; Gosling, L; Davidson, T A
2016-07-22
Public participation in scientific data collection is a rapidly expanding field. In water quality surveys, the involvement of the public, usually as trained volunteers, generally includes the identification of aquatic invertebrates to a broad taxonomic level. However, quality assurance is often not addressed and remains a key concern for the acceptance of publicly-generated water quality data. The Open Air Laboratories (OPAL) Water Survey, launched in May 2010, aimed to encourage interest and participation in water science by developing a 'low-barrier-to-entry' water quality survey. During 2010, over 3000 participant-selected lakes and ponds were surveyed making this the largest public participation lake and pond survey undertaken to date in the UK. But the OPAL approach of using untrained volunteers and largely anonymous data submission exacerbates quality control concerns. A number of approaches were used in order to address data quality issues including: sensitivity analysis to determine differences due to operator, sampling effort and duration; direct comparisons of identification between participants and experienced scientists; the use of a self-assessment identification quiz; the use of multiple participant surveys to assess data variability at single sites over short periods of time; comparison of survey techniques with other measurement variables and with other metrics generally considered more accurate. These quality control approaches were then used to screen the OPAL Water Survey data to generate a more robust dataset. The OPAL Water Survey results provide a regional and national assessment of water quality as well as a first national picture of water clarity (as suspended solids concentrations). Less than 10 % of lakes and ponds surveyed were 'poor' quality while 26.8 % were in the highest water quality band. It is likely that there will always be a question mark over untrained volunteer generated data simply because quality assurance is uncertain, regardless of any post hoc data analyses. Quality control at all stages, from survey design, identification tests, data submission and interpretation can all increase confidence such that useful data can be generated by public participants.
Audit and internal quality control in immunohistochemistry
Maxwell, P; McCluggage, W
2000-01-01
Aims—Although positive and negative controls are performed and checked in surgical pathology cases undergoing immunohistochemistry, internal quality control procedures for immunohistochemistry are not well described. This study, comprising a retrospective audit, aims to describe a method of internal quality control for immunohistochemistry. A scoring system that allows comparison between cases is described. Methods—Two positive tissue controls for each month over a three year period (1996–1998) of the 10 antibodies used most frequently were evaluated. All test cases undergoing immunohistochemistry in the months of April in this three year period were also studied. When the test case was completely negative for a given antibody, the corresponding positive tissue control from that day was examined. A marking system was devised whereby each immunohistochemical slide was assessed out of a possible score of 8 to take account of staining intensity, uniformity, specificity, background, and counterstaining. Using this scoring system, cases were classified as showing optimal (7–8), borderline (5–6), or unacceptable (0–4) staining. Results—Most positive tissue controls showed either optimal or borderline staining with the exception of neurone specific enolase (NSE), where most slides were unacceptable or borderline as a result of a combination of low intensity, poor specificity, and excessive background staining. All test cases showed either optimal or borderline staining with the exception of a single case stained for NSE, which was unacceptable. Conclusions—This retrospective audit shows that immunohistochemically stained slides can be assessed using this scoring system. With most antibodies, acceptable staining was achieved in most cases. However, there were problems with staining for NSE, which needs to be reviewed. Laboratories should use a system such as this to evaluate which antibodies regularly result in poor staining so that they can be excluded from panels. Routine evaluation of immunohistochemical staining should become part of everyday internal quality control procedures. Key Words: immunohistochemistry • audit • internal quality control PMID:11265178
NASA Astrophysics Data System (ADS)
Nguyen, Minh Q.; Allebach, Jan P.
2015-01-01
In our previous work1 , we presented a block-based technique to analyze printed page uniformity both visually and metrically. The features learned from the models were then employed in a Support Vector Machine (SVM) framework to classify the pages into one of the two categories of acceptable and unacceptable quality. In this paper, we introduce a set of tools for machine learning in the assessment of printed page uniformity. This work is primarily targeted to the printing industry, specifically the ubiquitous laser, electrophotographic printer. We use features that are well-correlated with the rankings of expert observers to develop a novel machine learning framework that allows one to achieve the minimum "false alarm" rate, subject to a chosen "miss" rate. Surprisingly, most of the research that has been conducted on machine learning does not consider this framework. During the process of developing a new product, test engineers will print hundreds of test pages, which can be scanned and then analyzed by an autonomous algorithm. Among these pages, most may be of acceptable quality. The objective is to find the ones that are not. These will provide critically important information to systems designers, regarding issues that need to be addressed in improving the printer design. A "miss" is defined to be a page that is not of acceptable quality to an expert observer that the prediction algorithm declares to be a "pass". Misses are a serious problem, since they represent problems that will not be seen by the systems designers. On the other hand, "false alarms" correspond to pages that an expert observer would declare to be of acceptable quality, but which are flagged by the prediction algorithm as "fails". In a typical printer testing and development scenario, such pages would be examined by an expert, and found to be of acceptable quality after all. "False alarm" pages result in extra pages to be examined by expert observers, which increases labor cost. But "false alarms" are not nearly as catastrophic as "misses", which represent potentially serious problems that are never seen by the systems developers. This scenario motivates us to develop a machine learning framework that will achieve the minimum "false alarm" rate subject to a specified "miss" rate. In order to construct such a set of receiver operating characteristic2 (ROC) curves, we examine various tools for the prediction, ranging from an exhaustive search over the space of the nonlinear discriminants to a Cost-Sentitive SVM3 framework. We then compare the curves gained from those methods. Our work shows promise for applying a standard framework to obtain a full ROC curve when it comes to tackling other machine learning problems in industry.
Amonsou, Eric Oscar; Sakyi-Dawson, Esther; Saalia, Firibu Kwesi; Houssou, Paul
2008-12-01
Griddled cowpea paste foods have high nutritional potential because they are low in fat but high in protein. A good understanding of process and product characteristics of kpejigaou is necessary to improve its quality and enhance acceptability. To describe the product, evaluate critical variables in traditional processing, and determine consumer quality criteria and preferences for kpejigaou. A survey of kpejigaou processing was carried out among processors and regular consumers of kpejigaou. Kpejigaou is flat and circular in shape, with uniform thickness and porous structure. The production process of kpejigaou was found to be simple and rapid, but the quality of the finished product varied among processors and among batches. Critical processing variables affecting quality were dehulling of the cowpeas, type of griddling equipment, and griddling temperature. Texture (sponginess) is the most important quality index that determines the preference and acceptability of kpejigaou by consumers. Traditionally processed kpejigaou does not meet current standards for high-quality foods. This study provides the basis for efforts to standardize the kpejigaou process to ensure consistent product quality and enhance the acceptability of kpejigaou among consumers. Kpejigaou has a potential for success if marketed as a low-fat, nutritious fast food.
Sensors control gas metal arc welding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Siewert, T.A.; Madigan, R.B.; Quinn, T.P.
1997-04-01
The response time of a trained welder from the time a weld problem is identified to the time action is taken is about one second--especially after a long, uneventful period of welding. This is acceptable for manual welding because it is close to the time it takes for the weld pool to solidify. If human response time were any slower, manual welding would not be possible. However, human response time is too slow to respond to some weld events, such as melting of the contact tube in gas metal arc welding (GMAW), and only automated intelligent control systems can reactmore » fast enough to correct or avoid these problems. Control systems incorporate welding knowledge that enables intelligent decisions to be made about weld quality and, ultimately, to keep welding parameters in the range where only high-quality welds are produced. This article discusses the correlation of electrical signals with contact-tube wear, changes in shielding gas, changes in arc length, and other weld process data.« less
Borras, J M; Sanchez-Hernandez, A; Navarro, M; Martinez, M; Mendez, E; Ponton, J L L; Espinas, J A; Germa, J R
2001-01-01
Objective To compare chemotherapy given at home with outpatient treatment in terms of colorectal cancer patients' safety, compliance, use of health services, quality of life, and satisfaction with treatment. Design Randomised controlled trial. Setting Large teaching hospital. Participants 87 patients receiving adjuvant or palliative chemotherapy for colorectal cancer. Interventions Treatment with fluorouracil (with or without folinic acid or levamisole) at outpatient clinic or at home. Main outcome measures Treatment toxicity; patients' compliance with treatment, quality of life, satisfaction with care, and use of health resources. Results 42 patients were treated at outpatient clinic and 45 at home. The two groups were balanced in terms of age, sex, site of cancer, and disease stage. Treatment related toxicity was similar in the two groups (difference 7% (95% confidence interval −12% to 26%)), but there were more voluntary withdrawals from treatment in the outpatient group than in the home group (14% v 2%, difference 12% (1% to 24%)). There were no differences between groups in terms of quality of life scores during and after treatment. Levels of patient satisfaction were higher in the home treatment group, specifically with regard to information received and nursing care. There were no significant differences in use of health services. Conclusions Home chemotherapy seemed an acceptable and safe alternative to hospital treatment for patients with colorectal cancer that may improve compliance and satisfaction with treatment. What is already known on this topicHome chemotherapy programmes have been proposed as an alternative to hospital treatmentHowever, they are more costly, and there is little evidence on their impact on outcomes such as compliance, quality of life, or use of other health servicesWhat this study addsHome chemotherapy was not associated with an increased use of health services such as primary care or emergency departmentsHome chemotherapy had no effect on patients' quality of life but increased their compliance with treatment and satisfaction, particularly with regard to nursing careHome chemotherapy seems an acceptable and safe alternative to outpatient treatment that may improve compliance with treatment PMID:11290635
[Quality of life in patients with age-related macular degeneration - medical and social problem].
Muzyka-Woźniak, Maria; Misiuk-Hojło, Marta; Wesolowska, Alicja
2011-01-01
Age-related macular degeneration (AMD) is a leading cause of blindness over the age of 50 in western countries. People with AMD are suffering from serious vision-related disability and their social life is compromised. The aim of our study was to assess quality of life (QoL) in patients with exudative AMD. The study group was 100 patients treated for AMD, the control group were 30 age and sex matched subjects without ophthalmic disorders. Patients were treated with anti-VEGF therapy, by means of National Eye Institute Visual Function Questionnaire (NEI VFQ-25). As well as visual function, the NEI-VFQ investigates social functioning, mental health and dependency. There was statistically significant difference in QoL overall score between study group and control group. Patients with AMD obtained 51.1 (+/- 20.5 ) overall score, control group reached 83.7 (+/- 11.7) overall score, p = 0.001. Detailed analysis of study group revealed low acceptance of the disease and strong dependency. QoL in patients with AMD assessed with NEI VFQ-25, is significantly impaired. Low quality of life and difficulties in performing daily activities point at the need of formal psychological and social care.
Statistical Quality Control of Moisture Data in GEOS DAS
NASA Technical Reports Server (NTRS)
Dee, D. P.; Rukhovets, L.; Todling, R.
1999-01-01
A new statistical quality control algorithm was recently implemented in the Goddard Earth Observing System Data Assimilation System (GEOS DAS). The final step in the algorithm consists of an adaptive buddy check that either accepts or rejects outlier observations based on a local statistical analysis of nearby data. A basic assumption in any such test is that the observed field is spatially coherent, in the sense that nearby data can be expected to confirm each other. However, the buddy check resulted in excessive rejection of moisture data, especially during the Northern Hemisphere summer. The analysis moisture variable in GEOS DAS is water vapor mixing ratio. Observational evidence shows that the distribution of mixing ratio errors is far from normal. Furthermore, spatial correlations among mixing ratio errors are highly anisotropic and difficult to identify. Both factors contribute to the poor performance of the statistical quality control algorithm. To alleviate the problem, we applied the buddy check to relative humidity data instead. This variable explicitly depends on temperature and therefore exhibits a much greater spatial coherence. As a result, reject rates of moisture data are much more reasonable and homogeneous in time and space.
Developing a consumer evaluation tool of weight control strategy advertisements on the Internet.
Luevorasirikul, Kanokrat; Gray, Nicola J; Anderson, Claire W
2008-06-01
To develop two evaluation tools for weight loss and weight gain advertisements on the Internet in order to help consumers to evaluate the quality of information within these advertisements. One hundred websites identified by Internet search engines for weight loss and weight gain strategies (50 websites each) were evaluated using two specific scoring instruments, developed by adapting questions from the 'DISCERN' tool and reviewing all related weight control guidelines and advertising regulations. The validity and reliability of the adapted tools were tested. Our evaluation tools rated the information from most websites as poor quality (70%). In the case of weight loss strategies, statements about rapid (18%) and permanent (28%) weight loss caused concern as well as lack of sensible advice about dieting and a lack of product warnings (84%). Safety concerns relating to weight gain products were the lack of warnings about side effects in products containing steroids and creatine (92%). The adapted tools exhibited acceptable validity and reliability. Quality of information within weight control advertisements on the Internet was generally poor. Problems of false claims, little advice on healthy ways to modify weight and few warnings on side effects have been highlighted in this study.
1981-10-02
acceptable levels under the worst case condition of coal firing. The flue gas desulfurization system would be designed to reduce the sulfer dioxide content...approaches taken. There exists federal statutory authority to implement gas rationing under certain conditions. Thus, federal controls on oil production...such as air quality deterioration, water consumption, P wastewater generation, disposal of flue gas scrubbing sludge, and ash. Another alternative is
Jones, A Kyle; Heintz, Philip; Geiser, William; Goldman, Lee; Jerjian, Khachig; Martin, Melissa; Peck, Donald; Pfeiffer, Douglas; Ranger, Nicole; Yorkston, John
2015-11-01
Quality control (QC) in medical imaging is an ongoing process and not just a series of infrequent evaluations of medical imaging equipment. The QC process involves designing and implementing a QC program, collecting and analyzing data, investigating results that are outside the acceptance levels for the QC program, and taking corrective action to bring these results back to an acceptable level. The QC process involves key personnel in the imaging department, including the radiologist, radiologic technologist, and the qualified medical physicist (QMP). The QMP performs detailed equipment evaluations and helps with oversight of the QC program, the radiologic technologist is responsible for the day-to-day operation of the QC program. The continued need for ongoing QC in digital radiography has been highlighted in the scientific literature. The charge of this task group was to recommend consistency tests designed to be performed by a medical physicist or a radiologic technologist under the direction of a medical physicist to identify problems with an imaging system that need further evaluation by a medical physicist, including a fault tree to define actions that need to be taken when certain fault conditions are identified. The focus of this final report is the ongoing QC process, including rejected image analysis, exposure analysis, and artifact identification. These QC tasks are vital for the optimal operation of a department performing digital radiography.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, A. Kyle, E-mail: kyle.jones@mdanderson.org; Geiser, William; Heintz, Philip
Quality control (QC) in medical imaging is an ongoing process and not just a series of infrequent evaluations of medical imaging equipment. The QC process involves designing and implementing a QC program, collecting and analyzing data, investigating results that are outside the acceptance levels for the QC program, and taking corrective action to bring these results back to an acceptable level. The QC process involves key personnel in the imaging department, including the radiologist, radiologic technologist, and the qualified medical physicist (QMP). The QMP performs detailed equipment evaluations and helps with oversight of the QC program, the radiologic technologist ismore » responsible for the day-to-day operation of the QC program. The continued need for ongoing QC in digital radiography has been highlighted in the scientific literature. The charge of this task group was to recommend consistency tests designed to be performed by a medical physicist or a radiologic technologist under the direction of a medical physicist to identify problems with an imaging system that need further evaluation by a medical physicist, including a fault tree to define actions that need to be taken when certain fault conditions are identified. The focus of this final report is the ongoing QC process, including rejected image analysis, exposure analysis, and artifact identification. These QC tasks are vital for the optimal operation of a department performing digital radiography.« less
Determination of Acidity in Donor Milk.
Escuder-Vieco, Diana; Vázquez-Román, Sara; Sánchez-Pallás, Juan; Ureta-Velasco, Noelia; Mosqueda-Peña, Rocío; Pallás-Alonso, Carmen Rosa
2016-11-01
There is no uniformity among milk banks on milk acceptance criteria. The acidity obtained by the Dornic titration technique is a widely used quality control in donor milk. However, there are no comparative data with other acidity-measuring techniques, such as the pH meter. The objective of this study was to assess the correlation between the Dornic technique and the pH measure to determine the pH cutoff corresponding to the Dornic degree limit value used as a reference for donor milk quality control. Fifty-two human milk samples were obtained from 48 donors. Acidity was measured using the Dornic method and pH meter in triplicate. Statistical data analysis to estimate significant correlations between variables was carried out. The Dornic acidity value that led to rejecting donor milk was ≥ 8 Dornic degrees (°D). In the evaluated sample size, Dornic acidity measure and pH values showed a statistically significant negative correlation (τ = -0.780; P = .000). A pH value of 6.57 corresponds to 8°D and of 7.12 to 4°D. Donor milk with a pH over 6.57 may be accepted for subsequent processing in the milk bank. Moreover, the pH measurement seems to be more useful due to certain advantages over the Dornic method, such as objectivity, accuracy, standardization, the lack of chemical reagents required, and the fact that it does not destroy the milk sample.
Natural Ventilation of Buildings through Light Shafts. Design-Based Solution Proposals
NASA Astrophysics Data System (ADS)
Ángel Padilla-Marcos, Miguel; Meiss, Alberto; Feijó-Muñoz, Jesús
2017-10-01
This work analyses how the built environment affects the quality of the air to be introduced into buildings from light shafts. Several factors such as urban environment and building design intervene in the ability of the light shaft to produce its air change process. Urban areas continuously pollute the air in cities which affects the human health and the environment sustainability. Poor air quality outside buildings supposes a big energy waste to promote an acceptable air quality inside buildings. That requires a large flow rate to maintain the indoor air quality which is translated to an energy efficiency term. The main objective focuses on the impact of standardized architecture design in the quality of the indoor air dependent on the air change in the light shaft. The air change capacity of the outdoor space is numbered analysed using the concept of air change efficiency (ACE). ACE is determined by the built environment, the wind conditions and the design of the building containing light shafts. This concept is comparatively evaluated inside a control domain virtually defined to obtain the mean age of the air for a known air volume. The longer the light shaft in the wind direction is, the better the ACE is compared with other options. Light shafts up to 12 metres high are the most suitable in order to obtain acceptable efficiency results. Other studied cases verify that assumption. Different simplified tools for the technicians to evaluate the design of buildings containing light shafts are proposed. Some strategies of architectural design of buildings with light shafts to be used for ventilation are presented.
Sezgin, Emre; Özkan-Yıldırım, Sevgi
Health information technologies have become vital to health care services. In that regard, successful use of information technologies in pharmaceutical services is important to manage, control and maintain pharmaceutical transactions, which increase the quality of health care delivery. This study aimed to identify influencing factors on pharmacists' acceptance of pharmaceutical service systems. A cross-sectional study was conducted employing a research model based on technology acceptance theories. A parsimonious model was developed, and a self-reported questionnaire was distributed online. Community pharmacists participated voluntarily via the website of Turkish Pharmacists' Association. The data was analyzed employing Structural Equation Modeling. From 77 out of 81 cities of Turkey, 2169 community pharmacists participated to the survey with 43% response rate. Perceived usefulness, perceived ease of use, system factors and perceived behavioral control explained 47% of total variance in pharmacists' intention to use the pharmaceutical technology. The findings of the research provided insight about relations of influencing factors and practical implications regarding perceived behaviors and system use. Future researchers would benefit from the study design and findings. The study is also valuable for being the first nationwide study conducted on pharmacists about user attitudes toward a technology. Copyright © 2015 Elsevier Inc. All rights reserved.
Noll, J.; Cecala, A.; Hummer, J.
2016-01-01
The National Institute for Occupational Safety and Health has observed that many control rooms and operator compartments in the U.S. mining industry do not have filtration systems capable of maintaining low dust concentrations in these areas. In this study at a mineral processing plant, to reduce respirable dust concentrations in a control room that had no cleaning system for intake air, a filtration and pressurization system originally designed for enclosed cabs was modified and installed. This system was composed of two filtering units: one to filter outside air and one to filter and recirculate the air inside the control room. Eighty-seven percent of submicrometer particles were reduced by the system under static conditions. This means that greater than 87 percent of respirable dust particles should be reduced as the particle-size distribution of respirable dust particles is greater than that of submicrometer particles, and filtration systems usually are more efficient in capturing the larger particles. A positive pressure near 0.02 inches of water gauge was produced, which is an important component of an effective system and minimizes the entry of particles, such as dust, into the room. The intake airflow was around 118 cfm, greater than the airflow suggested by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) for acceptable indoor air quality. After one year, the loading of the filter caused the airflow to decrease to 80 cfm, which still produces acceptable indoor air quality. Due to the loading of the filters, the reduction efficiency for submicrometer particles under static conditions increased to 94 percent from 87 percent. PMID:26834293
Promoting excellence in end-of-life care: a report on innovative models of palliative care.
Byock, Ira; Twohig, Jeanne Sheils; Merriman, Melanie; Collins, Karyn
2006-02-01
Promoting Excellence in End-of Life Care, a national program of The Robert Wood Johnson Foundation, funded 22 demonstration projects representing a wide range of health care settings and patient populations to develop innovative models for delivering palliative care that addressed documented deficiencies in the care of patients and families facing the final stage of life. To determine the practicality (feasibility of development and operation as well as acceptance by stakeholders) of new models of care and to determine the impact of the models on access to, quality of and financing for palliative care. The program cannot report scientifically rigorous outcomes, but the grant-funded projects used a variety of methods and measures to assess acceptance of new models and their impact from the perspectives of various stakeholders, including patients and their families, clinicians, administrators and payers. While it is not possible to aggregate data across projects, the data reported to the Promoting Excellence national program office were used to describe program impact with respect to the practicality of palliative care service integration into existing clinical care settings (feasibility and acceptance by stakeholders), the availability and use of palliative care services (access), quality of care (conformance to patient expectations and accepted clinical standards) and costs of care. The 22 projects provided services in urban as well as rural settings, in integrated health systems, hospitals, outpatient clinics, cancer centers, nursing homes, renal dialysis clinics, inner city public health and safety net systems and prisons. Populations served included prison inmates, military veterans, renal dialysis patients, Native Americans, Native Alaskans, and African American patients, inner-city medically underserved patients, pediatric patients, and persons with serious mental illness patients. Hosting or adopting institutions sustained or expanded twenty of the 22 models, and feedback from all stakeholders was positive. Project sites developed and utilized new palliative care services and addressed quality through implementation of new standards and clinical protocols. Costs of care, where they could be assessed, were unaffected or decreased for project patients versus historical or concurrent controls. The 22 Promoting Excellence in End-of Life Care projects demonstrated that by individualizing patient and family assessment, effectively employing existing resources and aligning services with specific patient and family needs, it is possible to expand access to palliative services and improve quality of care in ways that are financially feasible and acceptable to patients, families, clinicians, administrators, and payers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bray, R.W.; Weckel, K.G.; Evans, G.W.
1964-02-01
The influence of intramuscular fat (degree of marbling) on characteristics of precooked and irradiated pork muscle was studied. Loins were selected and categorized into three marbling levels by visual appraisal. A relatively high temperature (325 deg F) and short time (2 hr) heat treatment was used for enzyme inactivation. Samples were packed under vacuum in rigid containers and irradiated to 4.5 Mrad with gamma radiation. Irradiated and frozen control samples were evaluated up to 2l0 days later. Degree of marbling had no apparent influence on organoleptic properties of either irradiated or frozen control longissimus dorsi muscle samples. Frozen control samplesmore » were preferred in general appearance, flavor, and over-all acceptability by panelists. Irradiated samples were preferred in texture qualities. Storage time was not a major factor in organoleptic acceptability; however, acceptability of irradiated samples declined between 150 and 210 days of storage. Hunter color attributes were not affected by marbling level. L, a/sub L/ hue, and saturation were increased by radiation treatment. Mechanical tenderness values were decreased due to higher marbling level and radiation treatment. Expressible-moisture values were lowered by radiation treatment and increased with storage time. Iodine numbers were decreased by radiation. Degree of marbling did not affect thiobarbituric acid values but they were significantly lower for irradiated samples. pH values increased with higher levels of intramuscular fat, were significantly higher in irradiated samples than controls, and tended to increase steadily with advancing storage time. (BBB)« less
Variation in cooking and eating quality traits in Japanese rice germplasm accessions
Hori, Kiyosumi; Suzuki, Keitaro; Iijima, Ken; Ebana, Kaworu
2016-01-01
The eating quality of cooked rice is important and determines its market price and consumer acceptance. To comprehensively describe the variation of eating quality in 183 rice germplasm accessions, we evaluated 33 eating-quality traits including amylose and protein contents, pasting properties of rice flour, and texture of cooked rice grains. All eating-quality traits varied widely in the germplasm accessions. Principal-components analysis (PCA) revealed that allelic differences in the Wx gene explained the largest proportion of phenotypic variation of the eating-quality traits. In 146 accessions of non-glutinous temperate japonica rice, PCA revealed that protein content and surface texture of the cooked rice grains significantly explained phenotypic variations of the eating-quality traits. An allelic difference based on simple sequence repeats, which was located near a quantitative trait locus (QTL) on the short arm of chromosome 3, was associated with differences in the eating quality of non-glutinous temperate japonica rice. These results suggest that eating quality is controlled by genetic factors, including the Wx gene and the QTL on chromosome 3, in Japanese rice accessions. These genetic factors have been consciously selected for eating quality during rice breeding programs in Japan. PMID:27162502
Variation in cooking and eating quality traits in Japanese rice germplasm accessions.
Hori, Kiyosumi; Suzuki, Keitaro; Iijima, Ken; Ebana, Kaworu
2016-03-01
The eating quality of cooked rice is important and determines its market price and consumer acceptance. To comprehensively describe the variation of eating quality in 183 rice germplasm accessions, we evaluated 33 eating-quality traits including amylose and protein contents, pasting properties of rice flour, and texture of cooked rice grains. All eating-quality traits varied widely in the germplasm accessions. Principal-components analysis (PCA) revealed that allelic differences in the Wx gene explained the largest proportion of phenotypic variation of the eating-quality traits. In 146 accessions of non-glutinous temperate japonica rice, PCA revealed that protein content and surface texture of the cooked rice grains significantly explained phenotypic variations of the eating-quality traits. An allelic difference based on simple sequence repeats, which was located near a quantitative trait locus (QTL) on the short arm of chromosome 3, was associated with differences in the eating quality of non-glutinous temperate japonica rice. These results suggest that eating quality is controlled by genetic factors, including the Wx gene and the QTL on chromosome 3, in Japanese rice accessions. These genetic factors have been consciously selected for eating quality during rice breeding programs in Japan.