Sample records for acceptance ratio method

  1. Efficiencies of joint non-local update moves in Monte Carlo simulations of coarse-grained polymers

    NASA Astrophysics Data System (ADS)

    Austin, Kieran S.; Marenz, Martin; Janke, Wolfhard

    2018-03-01

    In this study four update methods are compared in their performance in a Monte Carlo simulation of polymers in continuum space. The efficiencies of the update methods and combinations thereof are compared with the aid of the autocorrelation time with a fixed (optimal) acceptance ratio. Results are obtained for polymer lengths N = 14, 28 and 42 and temperatures below, at and above the collapse transition. In terms of autocorrelation, the optimal acceptance ratio is approximately 0.4. Furthermore, an overview of the step sizes of the update methods that correspond to this optimal acceptance ratio is given. This shall serve as a guide for future studies that rely on efficient computer simulations.

  2. Can the prevalence of high blood drug concentrations in a population be estimated by analysing oral fluid? A study of tetrahydrocannabinol and amphetamine.

    PubMed

    Gjerde, Hallvard; Verstraete, Alain

    2010-02-25

    To study several methods for estimating the prevalence of high blood concentrations of tetrahydrocannabinol and amphetamine in a population of drug users by analysing oral fluid (saliva). Five methods were compared, including simple calculation procedures dividing the drug concentrations in oral fluid by average or median oral fluid/blood (OF/B) drug concentration ratios or linear regression coefficients, and more complex Monte Carlo simulations. Populations of 311 cannabis users and 197 amphetamine users from the Rosita-2 Project were studied. The results of a feasibility study suggested that the Monte Carlo simulations might give better accuracies than simple calculations if good data on OF/B ratios is available. If using only 20 randomly selected OF/B ratios, a Monte Carlo simulation gave the best accuracy but not the best precision. Dividing by the OF/B regression coefficient gave acceptable accuracy and precision, and was therefore the best method. None of the methods gave acceptable accuracy if the prevalence of high blood drug concentrations was less than 15%. Dividing the drug concentration in oral fluid by the OF/B regression coefficient gave an acceptable estimation of high blood drug concentrations in a population, and may therefore give valuable additional information on possible drug impairment, e.g. in roadside surveys of drugs and driving. If good data on the distribution of OF/B ratios are available, a Monte Carlo simulation may give better accuracy. 2009 Elsevier Ireland Ltd. All rights reserved.

  3. Cost-effectiveness acceptability curves and a reluctance to lose.

    PubMed

    Severens, Johan L; Brunenberg, Daniëlle E M; Fenwick, Elisabeth A L; O'Brien, Bernie; Joore, Manuela A

    2005-01-01

    Cost-effectiveness acceptability curves (CEACs) are a method used to present uncertainty surrounding incremental cost-effectiveness ratios (ICERs). Construction of the curves relies on the assumption that the willingness to pay (WTP) for health gain is identical to the willingness to accept (WTA) health loss. The objective of this paper is to explore the impact that differences between WTP and WTA health changes have on CEACs. Previous empirical evidence has shown that the relationship between WTP and WTA is not 1:1. The discrepancy between WTP and WTA for health changes can be expressed as a ratio: the accept/reject ratio (which can vary between 1 and infinity). Depending on this ratio, the area within the southwest quadrant of the cost-effectiveness plane in which any bootstrap cost-effect pairs will be considered to be cost effective will be smaller, resulting in a lower CEAC. We used data from two clinical trials to illustrate that relaxing the 1:1 WTP/WTA assumption has an impact on the CEACs. Given the difficulty in assessing the accept/reject ratio for every evaluation, we suggest presenting a series of CEACs for a range of values for the accept/reject ratio, including 1 and infinite. Although it is not possible to explain this phenomenon within the extra-welfarist framework, it has been shown empirically that individuals give a higher valuation to the removal of effective therapies than to the introduction of new therapies that are more costly and effective. In cost-effectiveness analyses where uncertainty of the ICER covers the southwest quadrant of the cost-effectiveness plane, the discrepancy between societies' WTP and WTA should be indicated by drawing multiple CEACs.

  4. Comparative study between univariate spectrophotometry and multivariate calibration as analytical tools for quantitation of Benazepril alone and in combination with Amlodipine.

    PubMed

    Farouk, M; Elaziz, Omar Abd; Tawakkol, Shereen M; Hemdan, A; Shehata, Mostafa A

    2014-04-05

    Four simple, accurate, reproducible, and selective methods have been developed and subsequently validated for the determination of Benazepril (BENZ) alone and in combination with Amlodipine (AML) in pharmaceutical dosage form. The first method is pH induced difference spectrophotometry, where BENZ can be measured in presence of AML as it showed maximum absorption at 237nm and 241nm in 0.1N HCl and 0.1N NaOH, respectively, while AML has no wavelength shift in both solvents. The second method is the new Extended Ratio Subtraction Method (EXRSM) coupled to Ratio Subtraction Method (RSM) for determination of both drugs in commercial dosage form. The third and fourth methods are multivariate calibration which include Principal Component Regression (PCR) and Partial Least Squares (PLSs). A detailed validation of the methods was performed following the ICH guidelines and the standard curves were found to be linear in the range of 2-30μg/mL for BENZ in difference and extended ratio subtraction spectrophotometric method, and 5-30 for AML in EXRSM method, with well accepted mean correlation coefficient for each analyte. The intra-day and inter-day precision and accuracy results were well within the acceptable limits. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Three different spectrophotometric methods manipulating ratio spectra for determination of binary mixture of Amlodipine and Atorvastatin

    NASA Astrophysics Data System (ADS)

    Darwish, Hany W.; Hassan, Said A.; Salem, Maissa Y.; El-Zeiny, Badr A.

    2011-12-01

    Three simple, specific, accurate and precise spectrophotometric methods manipulating ratio spectra are developed for the simultaneous determination of Amlodipine besylate (AM) and Atorvastatin calcium (AT) in tablet dosage forms. The first method is first derivative of the ratio spectra ( 1DD), the second is ratio subtraction and the third is the method of mean centering of ratio spectra. The calibration curve is linear over the concentration range of 3-40 and 8-32 μg/ml for AM and AT, respectively. These methods are tested by analyzing synthetic mixtures of the above drugs and they are applied to commercial pharmaceutical preparation of the subjected drugs. Standard deviation is <1.5 in the assay of raw materials and tablets. Methods are validated as per ICH guidelines and accuracy, precision, repeatability and robustness are found to be within the acceptable limit.

  6. Knowledge and Acceptability of Long-Acting Reversible Contraception Among Adolescent Women Receiving School-Based Primary Care Services

    PubMed Central

    Hoopes, Andrea J.; Ahrens, Kym R.; Gilmore, Kelly; Cady, Janet; Haaland, Wren L.; Amies Oelschlager, Anne-Marie; Prager, Sarah

    2016-01-01

    Background: A key strategy to reduce unintended adolescent pregnancies is to expand access to long-acting reversible contraceptive (LARC) methods, including intrauterine devices and subdermal contraceptive implants. LARC services can be provided to adolescents in school-based health and other primary care settings, yet limited knowledge and negative attitudes about LARC methods may influence adolescents’ utilization of these methods. This study aimed to evaluate correlates of knowledge and acceptability of LARC methods among adolescent women at a school-based health center (SBHC). Methods: In this cross-sectional study, female patients receiving care at 2 SBHCs in Seattle, Washington completed an electronic survey about sexual and reproductive health. Primary outcomes were (1) LARC knowledge as measured by percentage correct of 10 true-false questions and (2) LARC acceptability as measured by participants reporting either liking the idea of having an intrauterine device (IUD)/subdermal implant or currently using one. Results: A total of 102 students diverse in race/ethnicity and socioeconomic backgrounds completed the survey (mean age 16.2 years, range 14.4-19.1 years). Approximately half reported a lifetime history of vaginal sex. Greater LARC knowledge was associated with white race (regression coefficient [coef] = 26.8; 95% CI 13.3-40.4; P < .001), history of vaginal intercourse (coef = 29.9; 95% CI 17.1-42.7; P < .001), and current/prior LARC use (coef = 22.8; 95% CI 6.5-40.0; P = .007). Older age was associated with lower IUD acceptability (odds ratio = 0.53, 95% CI 0.30-0.94; P = .029) while history of intercourse was associated with greater implant acceptability (odds ratio 5.66, 95% CI 1.46-22.0; P = .012). Discussion: Adolescent women in this SBHC setting had variable knowledge and acceptability of LARC. A history of vaginal intercourse was the strongest predictor of LARC acceptability. Our findings suggest a need for LARC counseling and education strategies, particularly for young women from diverse cultural backgrounds and those with less sexual experience. PMID:27067583

  7. Sample size calculation in economic evaluations.

    PubMed

    Al, M J; van Hout, B A; Michel, B C; Rutten, F F

    1998-06-01

    A simulation method is presented for sample size calculation in economic evaluations. As input the method requires: the expected difference and variance of costs and effects, their correlation, the significance level (alpha) and the power of the testing method and the maximum acceptable ratio of incremental effectiveness to incremental costs. The method is illustrated with data from two trials. The first compares primary coronary angioplasty with streptokinase in the treatment of acute myocardial infarction, in the second trial, lansoprazole is compared with omeprazole in the treatment of reflux oesophagitis. These case studies show how the various parameters influence the sample size. Given the large number of parameters that have to be specified in advance, the lack of knowledge about costs and their standard deviation, and the difficulty of specifying the maximum acceptable ratio of incremental effectiveness to incremental costs, the conclusion of the study is that from a technical point of view it is possible to perform a sample size calculation for an economic evaluation, but one should wonder how useful it is.

  8. Comparative study between different simple methods manipulating ratio spectra for the analysis of alogliptin and metformin co-formulated with highly different concentrations

    NASA Astrophysics Data System (ADS)

    Zaghary, Wafaa A.; Mowaka, Shereen; Hassan, Mostafa A.; Ayoub, Bassam M.

    2017-11-01

    Different simple spectrophotometric methods were developed for simultaneous determination of alogliptin and metformin manipulating their ratio spectra with successful application on recently approved combination, Kazano® tablets. Spiking was implemented to detect alogliptin in spite of its low contribution in the pharmaceutical formulation as low quantity in comparison to metformin. Linearity was acceptable over the concentration range of 2.5-25.0 μg/mL and 2.5-15.0 μg/mL for alogliptin and metformin, respectively using derivative ratio, ratio subtraction coupled with extended ratio subtraction and spectrum subtraction coupled with constant multiplication. The optimized methods were compared using one-way analysis of variance (ANOVA) and proved to be accurate for assay of the investigated drugs in their pharmaceutical dosage form.

  9. Use and acceptance of electronic communication by patients with multiple sclerosis: a multicenter questionnaire study.

    PubMed

    Haase, Rocco; Schultheiss, Thorsten; Kempcke, Raimar; Thomas, Katja; Ziemssen, Tjalf

    2012-10-15

    The number of multiple sclerosis (MS) information websites, online communities, and Web-based health education programs has been increasing. However, MS patients' willingness to use new ways of communication, such as websites, mobile phone application, short message service, or email with their physician, remains unknown. We designed a questionnaire to evaluate the a priori use of electronic communication methods by MS patients and to assess their acceptance of such tools for communication with their health care providers. We received complete data from 586 MS patients aged between 17 and 73 years. Respondents were surveyed in outpatient clinics across Germany using a novel paper-and-pencil questionnaire. In addition to demographics, the survey items queried frequency of use of, familiarity with, and comfort with using computers, websites, email, and mobile phones. About 90% of all MS patients used a personal computer (534/586) and the Internet (527/586) at least once a week, 87.0% (510/586) communicated by email, and 85.6% (488/570) communicated by mobile phone. When asked about their comfort with using electronic communication methods for communication with health care providers, 20.5% (120/586) accepted communication by mobile Internet application or short message service via mobile phone, 41.0% (240/586) by websites, 54.3% (318/586) by email service, and 67.8% (397/586) by at least one type of electronic communication. The level of a priori use was the best predictor for the acceptance of electronic communication with health care providers. Patients who reported already searching online for health information (odds ratio 2.4, P < .001) and who had already communicated with a physician through a website (odds ratio 3.3, P = .03) reported higher acceptance for Web-based communication. Patients who already scheduled appointments with their mobile phones (odds ratio 2.1, P = .002) were more likely to accept the use of mobile phone applications or short message service for communicating with their physician. The majority of MS patients seen at specialist centers already use modern communication technology regularly. New forms of electronic communication appear to have high levels of acceptance for exchanging information about MS between patients and health care providers. Such methods should be integrated into eHealth services such as electronic health records and patient relationship management systems.

  10. Mean centering of double divisor ratio spectra, a novel spectrophotometric method for analysis of ternary mixtures

    NASA Astrophysics Data System (ADS)

    Hassan, Said A.; Elzanfaly, Eman S.; Salem, Maissa Y.; El-Zeany, Badr A.

    2016-01-01

    A novel spectrophotometric method was developed for determination of ternary mixtures without previous separation, showing significant advantages over conventional methods. The new method is based on mean centering of double divisor ratio spectra. The mathematical explanation of the procedure is illustrated. The method was evaluated by determination of model ternary mixture and by the determination of Amlodipine (AML), Aliskiren (ALI) and Hydrochlorothiazide (HCT) in laboratory prepared mixtures and in a commercial pharmaceutical preparation. For proper presentation of the advantages and applicability of the new method, a comparative study was established between the new mean centering of double divisor ratio spectra (MCDD) and two similar methods used for analysis of ternary mixtures, namely mean centering (MC) and double divisor of ratio spectra-derivative spectrophotometry (DDRS-DS). The method was also compared with a reported one for analysis of the pharmaceutical preparation. The method was validated according to the ICH guidelines and accuracy, precision, repeatability and robustness were found to be within the acceptable limits.

  11. Validated spectrophotometric methods for simultaneous determination of Omeprazole, Tinidazole and Doxycycline in their ternary mixture

    NASA Astrophysics Data System (ADS)

    Lotfy, Hayam M.; Hegazy, Maha A.; Mowaka, Shereen; Mohamed, Ekram Hany

    2016-01-01

    A comparative study of smart spectrophotometric techniques for the simultaneous determination of Omeprazole (OMP), Tinidazole (TIN) and Doxycycline (DOX) without prior separation steps is developed. These techniques consist of several consecutive steps utilizing zero/or ratio/or derivative spectra. The proposed techniques adopt nine simple different methods, namely direct spectrophotometry, dual wavelength, first derivative-zero crossing, amplitude factor, spectrum subtraction, ratio subtraction, derivative ratio-zero crossing, constant center, and successive derivative ratio method. The calibration graphs are linear over the concentration range of 1-20 μg/mL, 5-40 μg/mL and 2-30 μg/mL for OMP, TIN and DOX, respectively. These methods are tested by analyzing synthetic mixtures of the above drugs and successfully applied to commercial pharmaceutical preparation. The methods that are validated according to the ICH guidelines, accuracy, precision, and repeatability, were found to be within the acceptable limits.

  12. Smart manipulation of ratio spectra for resolving a pharmaceutical mixture of Methocarbamol and Paracetamol

    NASA Astrophysics Data System (ADS)

    Essam, Hebatallah M.; Abd-El Rahman, Mohamed K.

    2015-04-01

    Two smart, specific, accurate and precise spectrophotometric methods manipulating ratio spectra are developed for simultaneous determination of Methocarbamol (METH) and Paracetamol (PAR) in their combined pharmaceutical formulation without preliminary separation. Method A, is an extended ratio subtraction one (EXRSM) coupled with ratio subtraction method (RSM), which depends on subtraction of the plateau values from the ratio spectrum. Method B is a ratio difference spectrophotometric one (RDM) which measures the difference in amplitudes of ratio spectra between 278 and 286 nm for METH and 247 and 260 nm for PAR. The calibration curves are linear over the concentration range of 10-100 μg mL-1 and 2-20 μg mL-1 for METH and PAR, respectively. The specificity of the developed methods was investigated by analyzing different laboratory prepared mixtures of the two drugs. Both methods were applied successfully for the determination of the selected drugs in their combined dosage form. Furthermore, validation was performed according to ICH guidelines; accuracy, precision and repeatability are found to be within the acceptable limits. Statistical studies showed that both methods can be competitively applied in quality control laboratories.

  13. Cross-Cultural Consumer Acceptability and Purchase Intent of Forage-Finished Rib-Eye Steaks.

    PubMed

    Torrico, Damir Dennis; Wardy, Wisdom; Pujols, Kairy Dharali; Carabante, Kennet Mariano; Jirangrat, Wannita; Scaglia, Guillermo; Janes, Marlene E; Prinyawiwatkul, Witoon

    2015-10-01

    Rib-eye steaks, from 3 forage-finished systems (S1, S2, and S3) and 1 commercial steak (C), either cooked by 1-sided-grilling or 2-sided-grilling, were evaluated for sensory acceptability [overall appearance (ORA) and overall appearance of fat (OAF) for raw steaks; overall appearance (OCA), overall beef aroma (OBA), overall beef flavor (OBF), juiciness, tenderness and overall liking (OL) for cooked steaks] and purchase intent by Hispanic, Asian and U.S. consumers. They also indicated preferred degree of doneness and cooking methods. Cross-cultural differences in preferences and consumer acceptability of rib-eye steaks were observed. Grilling was the most preferred cooking method. Hispanics and Asians preferred medium and/or medium well, while U.S. consumers preferred medium and/or medium rare. For cooked steaks, the population effect was significant for all sensory attributes; Asians generally scored lower than did Hispanics and U.S. consumers. C and S3 generally had higher scores for all sensory attributes across 3 populations. Purchase intent for all forage-finished steaks was higher for Hispanics and U.S. consumers compared to Asians (50.0% to 77.8% compared with 43.2% to 65.9%). Attributes influencing purchase intent of forage-finished steaks differed among populations: tenderness (odds ratio = 1.4) for Hispanics, OCA (odds ratio = 1.5) for Asians, and OBF (odds ratio = 1.3) for U.S. consumers. Overall, this study demonstrated that the type of forage-finished system and ethnic differences influenced sensory acceptability and purchase intent of forage-finished rib-eye steaks. Demand for forage-finished beef has increased worldwide due to its potential health benefits. Little is known regarding the cross-cultural effects on the consumer acceptance of forage-finished beef. We evaluated sensory acceptance and purchase intent of raw and cooked forage-finished rib-eye steaks using Hispanic, Asian, and U.S. (White and African American) populations. This study demonstrated that consumer acceptability and purchase intent of forage-finished rib-eye steaks differed among Hispanic, Asian, and U.S. populations. This information can be used to guide development and marketing strategies for beef products. © 2015 Institute of Food Technologists®

  14. Knowledge and Acceptability of Long-Acting Reversible Contraception Among Adolescent Women Receiving School-Based Primary Care Services.

    PubMed

    Hoopes, Andrea J; Ahrens, Kym R; Gilmore, Kelly; Cady, Janet; Haaland, Wren L; Amies Oelschlager, Anne-Marie; Prager, Sarah

    2016-07-01

    A key strategy to reduce unintended adolescent pregnancies is to expand access to long-acting reversible contraceptive (LARC) methods, including intrauterine devices and subdermal contraceptive implants. LARC services can be provided to adolescents in school-based health and other primary care settings, yet limited knowledge and negative attitudes about LARC methods may influence adolescents' utilization of these methods. This study aimed to evaluate correlates of knowledge and acceptability of LARC methods among adolescent women at a school-based health center (SBHC). In this cross-sectional study, female patients receiving care at 2 SBHCs in Seattle, Washington completed an electronic survey about sexual and reproductive health. Primary outcomes were (1) LARC knowledge as measured by percentage correct of 10 true-false questions and (2) LARC acceptability as measured by participants reporting either liking the idea of having an intrauterine device (IUD)/subdermal implant or currently using one. A total of 102 students diverse in race/ethnicity and socioeconomic backgrounds completed the survey (mean age 16.2 years, range 14.4-19.1 years). Approximately half reported a lifetime history of vaginal sex. Greater LARC knowledge was associated with white race (regression coefficient [coef] = 26.8; 95% CI 13.3-40.4; P < .001), history of vaginal intercourse (coef = 29.9; 95% CI 17.1-42.7; P < .001), and current/prior LARC use (coef = 22.8; 95% CI 6.5-40.0; P = .007). Older age was associated with lower IUD acceptability (odds ratio = 0.53, 95% CI 0.30-0.94; P = .029) while history of intercourse was associated with greater implant acceptability (odds ratio 5.66, 95% CI 1.46-22.0; P = .012). Adolescent women in this SBHC setting had variable knowledge and acceptability of LARC. A history of vaginal intercourse was the strongest predictor of LARC acceptability. Our findings suggest a need for LARC counseling and education strategies, particularly for young women from diverse cultural backgrounds and those with less sexual experience. © The Author(s) 2016.

  15. Comparative study between different simple methods manipulating ratio spectra for the analysis of alogliptin and metformin co-formulated with highly different concentrations.

    PubMed

    Zaghary, Wafaa A; Mowaka, Shereen; Hassan, Mostafa A; Ayoub, Bassam M

    2017-11-05

    Different simple spectrophotometric methods were developed for simultaneous determination of alogliptin and metformin manipulating their ratio spectra with successful application on recently approved combination, Kazano® tablets. Spiking was implemented to detect alogliptin in spite of its low contribution in the pharmaceutical formulation as low quantity in comparison to metformin. Linearity was acceptable over the concentration range of 2.5-25.0μg/mL and 2.5-15.0μg/mL for alogliptin and metformin, respectively using derivative ratio, ratio subtraction coupled with extended ratio subtraction and spectrum subtraction coupled with constant multiplication. The optimized methods were compared using one-way analysis of variance (ANOVA) and proved to be accurate for assay of the investigated drugs in their pharmaceutical dosage form. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Factors Associated With Contraceptive Method Choice and Initiation in Adolescents and Young Women.

    PubMed

    Cohen, Rebecca; Sheeder, Jeanelle; Kane, Meghan; Teal, Stephanie B

    2017-10-01

    The purpose of the study was to identify factors associated with uptake of contraceptive implants or intrauterine devices (IUDs) by adolescents and young women. For this prospective cohort study, we recruited English-speaking female contraceptive initiators aged 14-24 years attending a Title X-supported, youth-focused clinic. Immediately prior to their visits, participants completed surveys assessing demographic and reproductive characteristics and awareness of, interest in, and intent to initiate specific contraceptive methods. Participants also answered questions about their social contacts' contraceptive experiences. Following the visit, participants reported the method initiated and the perceived importance of provider counseling. We used a multivariable regression model to ascertain factors associated with initiation of an IUD, an implant, or a short-acting reversible method. We enrolled 1,048 contraceptive initiators: 277 initiated short-acting methods, 384 IUDs, and 387 implants. High previsit personal acceptability of the method was associated with choosing that method for both implants and IUDs. Knowing someone who uses a specific method and likes it was predictive of personal acceptability of that method (IUD adjusted odds ratio: 10.9, 95% confidence interval: 3.8-31.1; implant adjusted odds ratio: 7.0, 95% confidence interval: 2.3-21.0). However, 10.4% of those initiating IUDs and 14.2% of those initiating implants had never heard of the method before their appointment. Even women with previsit intent to initiate a specific method found importance in contraceptive counseling. Previsit personal acceptability, which was associated with social contacts' experiences, was the strongest predictor of specific method uptake in our study. However, counseling informed the decisions of those with low previsit awareness and supported patients with formed intent. Copyright © 2017 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  17. Use of the Vettest 8008 and refractometry for determination of total protein, albumin, and globulin concentrations in feline effusions.

    PubMed

    Papasouliotis, Kostas; Murphy, Kate; Dodkin, Steve; Torrance, Andy G

    2002-01-01

    Pleural and peritoneal effusion is a common clinical finding in feline practice. Determination of fluid albumin (ALB) and globulin (GLOB) concentrations in addition to total protein (TP) concentration can be helpful in diagnosing or ruling out certain diseases in cats, especially feline infectious peritonitis (FIP). The objective of this study was to compare effusion TP, ALB, and GLOB results obtained by a refractometer and a bench-top dry chemistry analyzer with those results obtained by a reference method. Twenty-six pleural and 14 peritoneal effusion samples were analyzed from 40 cats with various diseases. TP and ALB concentrations were determined by a reference automated wet chemistry analyzer (Kone Specific, Kone Instruments, Espoo, Finland), a bench-top dry chemistry analyzer (Vettest 8008, IDEXX Laboratories Ltd, Chalfont St Peter, UK), and a refractometer (Atago SPR-T2, Atago Co, Tokyo, Japan). GLOB, albumin to globulin (A/G) ratio, and globulins as a percentage of total proteins (GLOB%) were calculated. Results were analyzed by paired t tests, difference plots, and Deming s regression analysis. Correlation coefficients (r) for TP with Vettest versus Kone and refractometer versus Kone methods were.97 and.94, respectively. GLOB and GLOB% values were significantly higher and A/G ratios were significantly lower with Vettest versus Kone methods. Correlation coefficients for ALB, GLOB, GLOB% and A/G ratio with Vettest versus Kone methods were.86,.93,.82, and.73, respectively. Although correlation with other methods was good, the refractometer underestimated TP concentrations in 3 samples. The refractometer is an acceptable method for determination of TP concentration in feline effusions. The Vettest 8008 also is an acceptable method for the determination of TP and ALB concentrations, however, calculated A/G ratios obtained with the Vettest are unacceptable.

  18. Monte Carlo simulations for the free energies of C60 and C70 fullerene crystals by acceptance ratio method and expanded ensemble method

    NASA Astrophysics Data System (ADS)

    Kim, Minkyu; Chang, Jaeeon; Sandler, Stanley I.

    2014-02-01

    Accurate values of the free energies of C60 and C70 fullerene crystals are obtained using expanded ensemble method and acceptance ratio method combined with the Einstein-molecule approach. Both simulation methods, when tested for Lennard-Jones crystals, give accurate results of the free energy differing from each other in the fifth significant digit. The solid-solid phase transition temperature of C60 crystal is determined from free energy profiles, and found to be 260 K, which is in good agreement with experiment. For C70 crystal, using the potential model of Sprik et al. [Phys. Rev. Lett. 69, 1660 (1992)], low-temperature solid-solid phase transition temperature is found to be 160 K determined from the free energy profiles. Whereas this is somewhat lower than the experimental value, it is in agreement with conventional molecular simulations, which validates the methodological consistency of the present simulation method. From the calculations of the free energies of C60 and C70 crystals, we note the significance of symmetry number for crystal phase needed to properly account for the indistinguishability of orientationally disordered states.

  19. Simulated tempering based on global balance or detailed balance conditions: Suwa-Todo, heat bath, and Metropolis algorithms.

    PubMed

    Mori, Yoshiharu; Okumura, Hisashi

    2015-12-05

    Simulated tempering (ST) is a useful method to enhance sampling of molecular simulations. When ST is used, the Metropolis algorithm, which satisfies the detailed balance condition, is usually applied to calculate the transition probability. Recently, an alternative method that satisfies the global balance condition instead of the detailed balance condition has been proposed by Suwa and Todo. In this study, ST method with the Suwa-Todo algorithm is proposed. Molecular dynamics simulations with ST are performed with three algorithms (the Metropolis, heat bath, and Suwa-Todo algorithms) to calculate the transition probability. Among the three algorithms, the Suwa-Todo algorithm yields the highest acceptance ratio and the shortest autocorrelation time. These suggest that sampling by a ST simulation with the Suwa-Todo algorithm is most efficient. In addition, because the acceptance ratio of the Suwa-Todo algorithm is higher than that of the Metropolis algorithm, the number of temperature states can be reduced by 25% for the Suwa-Todo algorithm when compared with the Metropolis algorithm. © 2015 Wiley Periodicals, Inc.

  20. Green Pharmaceutical Analysis of Drugs Coformulated with Highly Different Concentrations Using Spiking and Manipulation of Their Ratio Spectra.

    PubMed

    Ayoub, Bassam M

    2017-07-01

    Introducing green analysis to pharmaceutical products is considered a significant approach to preserving the environment. This method can be an environmentally friendly alternative to the existing methods, accompanied by a validated automated procedure for the analysis of a drug with the lowest possible number of samples. Different simple spectrophotometric methods were developed for the simultaneous determination of empagliflozin (EG) and metformin (MT) by manipulating their ratio spectra in their application on a recently approved pharmaceutical combination, Synjardy tablets. A spiking technique was used to increase the concentration of EG in samples prepared from the tablets to allow for the simultaneous determination of EG with MT without prior separation. Validation parameters according to International Conference on Harmonization guidelines were acceptable over a concentration range of 2-12 μg/mL for both drugs using derivative ratio and ratio subtraction coupled with extended ratio subtraction. The optimized methods were compared using one-way analysis of variance and proved to be suitable as ecofriendly approaches for industrial QC laboratories.

  1. Fully iterative scatter corrected digital breast tomosynthesis using GPU-based fast Monte Carlo simulation and composition ratio update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Kyungsang; Ye, Jong Chul, E-mail: jong.ye@kaist.ac.kr; Lee, Taewon

    2015-09-15

    Purpose: In digital breast tomosynthesis (DBT), scatter correction is highly desirable, as it improves image quality at low doses. Because the DBT detector panel is typically stationary during the source rotation, antiscatter grids are not generally compatible with DBT; thus, a software-based scatter correction is required. This work proposes a fully iterative scatter correction method that uses a novel fast Monte Carlo simulation (MCS) with a tissue-composition ratio estimation technique for DBT imaging. Methods: To apply MCS to scatter estimation, the material composition in each voxel should be known. To overcome the lack of prior accurate knowledge of tissue compositionmore » for DBT, a tissue-composition ratio is estimated based on the observation that the breast tissues are principally composed of adipose and glandular tissues. Using this approximation, the composition ratio can be estimated from the reconstructed attenuation coefficients, and the scatter distribution can then be estimated by MCS using the composition ratio. The scatter estimation and image reconstruction procedures can be performed iteratively until an acceptable accuracy is achieved. For practical use, (i) the authors have implemented a fast MCS using a graphics processing unit (GPU), (ii) the MCS is simplified to transport only x-rays in the energy range of 10–50 keV, modeling Rayleigh and Compton scattering and the photoelectric effect using the tissue-composition ratio of adipose and glandular tissues, and (iii) downsampling is used because the scatter distribution varies rather smoothly. Results: The authors have demonstrated that the proposed method can accurately estimate the scatter distribution, and that the contrast-to-noise ratio of the final reconstructed image is significantly improved. The authors validated the performance of the MCS by changing the tissue thickness, composition ratio, and x-ray energy. The authors confirmed that the tissue-composition ratio estimation was quite accurate under a variety of conditions. Our GPU-based fast MCS implementation took approximately 3 s to generate each angular projection for a 6 cm thick breast, which is believed to make this process acceptable for clinical applications. In addition, the clinical preferences of three radiologists were evaluated; the preference for the proposed method compared to the preference for the convolution-based method was statistically meaningful (p < 0.05, McNemar test). Conclusions: The proposed fully iterative scatter correction method and the GPU-based fast MCS using tissue-composition ratio estimation successfully improved the image quality within a reasonable computational time, which may potentially increase the clinical utility of DBT.« less

  2. Practical in-situ determination of ortho-para hydrogen ratios via fiber-optic based Raman spectroscopy

    DOE PAGES

    Sutherland, Liese -Marie; Knudson, James N.; Mocko, Michal; ...

    2015-12-17

    An experiment was designed and developed to prototype a fiber-optic-based laser system, which measures the ratio of ortho-hydrogen to para-hydrogen in an operating neutron moderator system at the Los Alamos Neutron Science Center (LANSCE) spallation neutron source. Preliminary measurements resulted in an ortho to para ratio of 3.06:1, which is within acceptable agreement with the previously published ratio. As a result, the successful demonstration of Raman Spectroscopy for this measurement is expected to lead to a practical method that can be applied for similar in-situ measurements at operating neutron spallation sources.

  3. Practical in-situ determination of ortho-para hydrogen ratios via fiber-optic based Raman spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sutherland, Liese -Marie; Knudson, James N.; Mocko, Michal

    An experiment was designed and developed to prototype a fiber-optic-based laser system, which measures the ratio of ortho-hydrogen to para-hydrogen in an operating neutron moderator system at the Los Alamos Neutron Science Center (LANSCE) spallation neutron source. Preliminary measurements resulted in an ortho to para ratio of 3.06:1, which is within acceptable agreement with the previously published ratio. As a result, the successful demonstration of Raman Spectroscopy for this measurement is expected to lead to a practical method that can be applied for similar in-situ measurements at operating neutron spallation sources.

  4. Inter-laboratory verification of European pharmacopoeia monograph on derivative spectrophotometry method and its application for chitosan hydrochloride.

    PubMed

    Marković, Bojan; Ignjatović, Janko; Vujadinović, Mirjana; Savić, Vedrana; Vladimirov, Sote; Karljiković-Rajić, Katarina

    2015-01-01

    Inter-laboratory verification of European pharmacopoeia (EP) monograph on derivative spectrophotometry (DS) method and its application for chitosan hydrochloride was carried out on two generation of instruments (earlier GBC Cintra 20 and current technology TS Evolution 300). Instruments operate with different versions of Savitzky-Golay algorithm and modes of generating digital derivative spectra. For resolution power parameter, defined as the amplitude ratio A/B in DS method EP monograph, comparable results were obtained only with algorithm's parameters smoothing points (SP) 7 and the 2nd degree polynomial and those provided corresponding data with other two modes on TS Evolution 300 Medium digital indirect and Medium digital direct. Using quoted algorithm's parameters, the differences in percentages between the amplitude ratio A/B averages, were within accepted criteria (±3%) for assay of drug product for method transfer. The deviation of 1.76% for the degree of deacetylation assessment of chitosan hydrochloride, determined on two instruments, (amplitude (1)D202; the 2nd degree polynomial and SP 9 in Savitzky-Golay algorithm), was acceptable, since it was within allowed criteria (±2%) for assay deviation of drug substance, for method transfer in pharmaceutical analyses. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. 1H Spectroscopic Imaging of Human Brain at 3T: Comparison of Fast 3D-MRSI Techniques

    PubMed Central

    Zierhut, Matthew L.; Ozturk-Isik, Esin; Chen, Albert P.; Park, Ilwoo; Vigneron, Daniel B.; Nelson, Sarah J.

    2011-01-01

    Purpose To investigate the signal-to-noise-ratio (SNR) and data quality of time-reduced 1H 3D-MRSI techniques in the human brain at 3T. Materials and Methods Techniques that were investigated included ellipsoidal k-space sampling, parallel imaging, and EPSI. The SNR values for NAA, Cho, Cre, and lactate or lipid peaks were compared after correcting for effective spatial resolution and acquisition time in a phantom and in the brains of human volunteers. Other factors considered were linewidths, metabolite ratios, partial volume effects, and subcutaneous lipid contamination. Results In volunteers, the median normalized SNR for parallel imaging data decreased by 34–42%, but could be significantly improved using regularization. The normalized signal to noise loss in flyback EPSI data was 11–18%. The effective spatial resolutions of the traditional, ellipsoidal, SENSE, and EPSI data were 1.02, 2.43, 1.03, and 1.01cm3, respectively. As expected, lipid contamination was variable between subjects but was highest for the SENSE data. Patient data obtained using the flyback EPSI method were of excellent quality. Conclusions Data from all 1H 3D-MRSI techniques were qualitatively acceptable, based upon SNR, linewidths, and metabolite ratios. The larger FOV obtained with the EPSI methods showed negligible lipid aliasing with acceptable SNR values in less than 9.5 minutes without compromising the PSF. PMID:19711396

  6. Comparative study between recent methods manipulating ratio spectra and classical methods based on two-wavelength selection for the determination of binary mixture of antazoline hydrochloride and tetryzoline hydrochloride

    NASA Astrophysics Data System (ADS)

    Abdel-Halim, Lamia M.; Abd-El Rahman, Mohamed K.; Ramadan, Nesrin K.; EL Sanabary, Hoda F. A.; Salem, Maissa Y.

    2016-04-01

    A comparative study was developed between two classical spectrophotometric methods (dual wavelength method and Vierordt's method) and two recent methods manipulating ratio spectra (ratio difference method and first derivative of ratio spectra method) for simultaneous determination of Antazoline hydrochloride (AN) and Tetryzoline hydrochloride (TZ) in their combined pharmaceutical formulation and in the presence of benzalkonium chloride as a preservative without preliminary separation. The dual wavelength method depends on choosing two wavelengths for each drug in a way so that the difference in absorbance at those two wavelengths is zero for the other drug. While Vierordt's method, is based upon measuring the absorbance and the absorptivity values of the two drugs at their λmax (248.0 and 219.0 nm for AN and TZ, respectively), followed by substitution in the corresponding Vierordt's equation. Recent methods manipulating ratio spectra depend on either measuring the difference in amplitudes of ratio spectra between 255.5 and 269.5 nm for AN and 220.0 and 273.0 nm for TZ in case of ratio difference method or computing first derivative of the ratio spectra for each drug then measuring the peak amplitude at 250.0 nm for AN and at 224.0 nm for TZ in case of first derivative of ratio spectrophotometry. The specificity of the developed methods was investigated by analyzing different laboratory prepared mixtures of the two drugs. All methods were applied successfully for the determination of the selected drugs in their combined dosage form proving that the classical spectrophotometric methods can still be used successfully in analysis of binary mixture using minimal data manipulation rather than recent methods which require relatively more steps. Furthermore, validation of the proposed methods was performed according to ICH guidelines; accuracy, precision and repeatability are found to be within the acceptable limits. Statistical studies showed that the methods can be competitively applied in quality control laboratories.

  7. A practical approach to determination of laboratory GC-MS limits of detection.

    PubMed

    Underwood, P J; Kananen, G E; Armitage, E K

    1997-01-01

    Determination of limit of detection (LOD) values in a forensic laboratory serves a fundamental forensic requirement for assay performance. In addition to demonstrating assay capability, LOD values can also be used to fulfill certification requirements of a high-volume forensic drug laboratory. The LOD was defined as the lowest concentration of drug that the laboratory can detect in a specimen with forensic certainty at a minimum of 85% of the time. Overall batch acceptance criteria included acceptable quantitation of control materials (within 20% of target), acceptable chromatography (symmetry, peak integration, peak shape, peak, and baseline resolution), retention time within +/-1% of the extracted standard, and mass ion ratios within +/-20% of the extracted standard mass ion ratios. Individual specimen acceptance criteria were the same as the batch acceptance criteria excluding the quantitation requirement. Data were collected from all instruments on different runs. A minimum of ten data points was required for each certified instrument, and a minimum of 85% of data points was acceptable. Quantitation within +/-20% of the LOD concentration was not required, but acceptable mass ratios were required. Data points with poor chromatography (internal standard failed mass ratios; interference of the baseline, for example, shoulders; asymmetry; and baseline resolution) was omitted from the acceptable rate calculation. Data points with good chromatography with failed mass ion ratios were included in the acceptable rate calculation. With these criteria, we established the following LODs: 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid, 2 ng/mL; benzoylecgonine, 5 ng/mL; phencyclidine, 2.5 ng/mL; amphetamine, 150 ng/mL; methamphetamine, 100 ng/mL; codeine, 500 ng/mL; and morphine, 1000 ng/mL.

  8. Three different methods for determination of binary mixture of Amlodipine and Atorvastatin using dual wavelength spectrophotometry

    NASA Astrophysics Data System (ADS)

    Darwish, Hany W.; Hassan, Said A.; Salem, Maissa Y.; El-Zeany, Badr A.

    2013-03-01

    Three simple, specific, accurate and precise spectrophotometric methods depending on the proper selection of two wavelengths are developed for the simultaneous determination of Amlodipine besylate (AML) and Atorvastatin calcium (ATV) in tablet dosage forms. The first method is the new Ratio Difference method, the second method is the Bivariate method and the third one is the Absorbance Ratio method. The calibration curve is linear over the concentration range of 4-40 and 8-32 μg/mL for AML and ATV, respectively. These methods are tested by analyzing synthetic mixtures of the above drugs and they are applied to commercial pharmaceutical preparation of the subjected drugs. Methods are validated according to the ICH guidelines and accuracy, precision, repeatability and robustness are found to be within the acceptable limit. The mathematical explanation of the procedures is illustrated.

  9. Manipulating Ratio Spectra for the Spectrophotometric Analysis of Diclofenac Sodium and Pantoprazole Sodium in Laboratory Mixtures and Tablet Formulation

    PubMed Central

    Bhatt, Nejal M.; Chavada, Vijay D.; Sanyal, Mallika; Shrivastav, Pranav S.

    2014-01-01

    Objective. Three sensitive, selective, and precise spectrophotometric methods based on manipulation of ratio spectra, have been developed and validated for the determination of diclofenac sodium and pantoprazole sodium. Materials and Methods. The first method is based on ratio spectra peak to peak measurement using the amplitudes at 251 and 318 nm; the second method involves the first derivative of the ratio spectra (Δλ = 4 nm) using the peak amplitudes at 326.0 nm for diclofenac sodium and 337.0 nm for pantoprazole sodium. The third is the method of mean centering of ratio spectra using the values at 318.0 nm for both the analytes. Results. All the three methods were linear over the concentration range of 2.0–24.0 μg/mL for diclofenac sodium and 2.0–20.0 μg/mL for pantoprazole sodium. The methods were validated according to the ICH guidelines and accuracy, precision, repeatability, and robustness are found to be within the acceptable limit. The results of single factor ANOVA analysis indicated that there is no significant difference among the developed methods. Conclusions. The developed methods provided simple resolution of this binary combination from laboratory mixtures and pharmaceutical preparations and can be conveniently adopted for routine quality control analysis. PMID:24701171

  10. Measuring digit lengths with 3D digital stereophotogrammetry: A comparison across methods.

    PubMed

    Gremba, Allison; Weinberg, Seth M

    2018-05-09

    We compared digital 3D stereophotogrammetry to more traditional measurement methods (direct anthropometry and 2D scanning) to capture digit lengths and ratios. The length of the second and fourth digits was measured by each method and the second-to-fourth ratio was calculated. For each digit measurement, intraobserver agreement was calculated for each of the three collection methods. Further, measurements from the three methods were compared directly to one another. Agreement statistics included the intraclass correlation coefficient (ICC) and technical error of measurement (TEM). Intraobserver agreement statistics for the digit length measurements were high for all three methods; ICC values exceeded 0.97 and TEM values were below 1 mm. For digit ratio, intraobserver agreement was also acceptable for all methods, with direct anthropometry exhibiting lower agreement (ICC = 0.87) compared to indirect methods. For the comparison across methods, the overall agreement was high for digit length measurements (ICC values ranging from 0.93 to 0.98; TEM values below 2 mm). For digit ratios, high agreement was observed between the two indirect methods (ICC = 0.93), whereas indirect methods showed lower agreement when compared to direct anthropometry (ICC < 0.75). Digit measurements and derived ratios from 3D stereophotogrammetry showed high intraobserver agreement (similar to more traditional methods) suggesting that landmarks could be placed reliably on 3D hand surface images. While digit length measurements were found to be comparable across all three methods, ratios derived from direct anthropometry tended to be higher than those calculated indirectly from 2D or 3D images. © 2018 Wiley Periodicals, Inc.

  11. Different spectrophotometric methods applied for the analysis of simeprevir in the presence of its oxidative degradation product: Acomparative study

    NASA Astrophysics Data System (ADS)

    Attia, Khalid A. M.; El-Abasawi, Nasr M.; El-Olemy, Ahmed; Serag, Ahmed

    2018-02-01

    Five simple spectrophotometric methods were developed for the determination of simeprevir in the presence of its oxidative degradation product namely, ratio difference, mean centering, derivative ratio using the Savitsky-Golay filters, second derivative and continuous wavelet transform. These methods are linear in the range of 2.5-40 μg/mL and validated according to the ICH guidelines. The obtained results of accuracy, repeatability and precision were found to be within the acceptable limits. The specificity of the proposed methods was tested using laboratory prepared mixtures and assessed by applying the standard addition technique. Furthermore, these methods were statistically comparable to RP-HPLC method and good results were obtained. So, they can be used for the routine analysis of simeprevir in quality-control laboratories.

  12. Asymmetric design for Compound Elliptical Concentrators (CEC) and its geometric flux implications

    NASA Astrophysics Data System (ADS)

    Jiang, Lun; Winston, Roland

    2015-08-01

    The asymmetric compound elliptical concentrator (CEC) has been a less discussed subject in the nonimaging optics society. The conventional way of understanding an ideal concentrator is based on maximizing the concentration ratio based on a uniformed acceptance angle. Although such an angle does not exist in the case of CEC, the thermodynamic laws still hold and we can produce concentrators with the maximum concentration ratio allowed by them. Here we restate the problem and use the string method to solve this general problem. Built on the solution, we can discover groups of such ideal concentrators using geometric flux field, or flowline method.

  13. Rectification of depth measurement using pulsed thermography with logarithmic peak second derivative method

    NASA Astrophysics Data System (ADS)

    Li, Xiaoli; Zeng, Zhi; Shen, Jingling; Zhang, Cunlin; Zhao, Yuejin

    2018-03-01

    Logarithmic peak second derivative (LPSD) method is the most popular method for depth prediction in pulsed thermography. It is widely accepted that this method is independent of defect size. The theoretical model for LPSD method is based on the one-dimensional solution of heat conduction without considering the effect of defect size. When a decay term considering defect aspect ratio is introduced into the solution to correct the three-dimensional thermal diffusion effect, we found that LPSD method is affected by defect size by analytical model. Furthermore, we constructed the relation between the characteristic time of LPSD method and defect aspect ratio, which was verified with the experimental results of stainless steel and glass fiber reinforced plate (GFRP) samples. We also proposed an improved LPSD method for depth prediction when the effect of defect size was considered, and the rectification results of stainless steel and GFRP samples were presented and discussed.

  14. The TG/HDL-C Ratio Might Be a Surrogate for Insulin Resistance in Chinese Nonobese Women.

    PubMed

    He, Jiyun; He, Sen; Liu, Kai; Wang, Yong; Shi, Di; Chen, Xiaoping

    2014-01-01

    Obejective. To examine the discriminatory power of triglyceride (TG) and triglyceride to high-density lipoprotein cholesterol ratio (TG/HDL-C) for insulin resistance (IR) in a normoglycaemic Chinese population. Methods. The data were collected from 711 individuals. The normoglycaemic individuals were eventually included in the study (n = 533, age: 62.8 ± 6.6 years, male: 56.8%), who were with a fasting plasma glucose < 6.1 mmol/L and without a history of diabetes. IR was defined as the upper quintile (≥1.6) of homeostasis model assessment of IR. Area under the receiver operating characteristic curve (AROC) was used to examine the discriminatory power. Results. The discriminatory power of TG/HDL-C for IR was acceptable in women with a BMI < 24 kg/m(2) or waist circumference < 80 cm (AROCs: 0.718 and 0.713, resp.); however, the discriminatory power was not acceptable in the obese women. TG/HDL-C was not an acceptable marker of IR in men. The discriminatory power of TG for IR was not acceptable in both men and women. Conclusions. The discriminatory power of TG/HDL-C for IR differs by gender and obesity index in the normoglycaemic Chinese population, and TG/HDL-C could discriminate IR in the nonobese and normoglycaemic women.

  15. Multiensemble Markov models of molecular thermodynamics and kinetics.

    PubMed

    Wu, Hao; Paul, Fabian; Wehmeyer, Christoph; Noé, Frank

    2016-06-07

    We introduce the general transition-based reweighting analysis method (TRAM), a statistically optimal approach to integrate both unbiased and biased molecular dynamics simulations, such as umbrella sampling or replica exchange. TRAM estimates a multiensemble Markov model (MEMM) with full thermodynamic and kinetic information at all ensembles. The approach combines the benefits of Markov state models-clustering of high-dimensional spaces and modeling of complex many-state systems-with those of the multistate Bennett acceptance ratio of exploiting biased or high-temperature ensembles to accelerate rare-event sampling. TRAM does not depend on any rate model in addition to the widely used Markov state model approximation, but uses only fundamental relations such as detailed balance and binless reweighting of configurations between ensembles. Previous methods, including the multistate Bennett acceptance ratio, discrete TRAM, and Markov state models are special cases and can be derived from the TRAM equations. TRAM is demonstrated by efficiently computing MEMMs in cases where other estimators break down, including the full thermodynamics and rare-event kinetics from high-dimensional simulation data of an all-atom protein-ligand binding model.

  16. Multiensemble Markov models of molecular thermodynamics and kinetics

    PubMed Central

    Wu, Hao; Paul, Fabian; Noé, Frank

    2016-01-01

    We introduce the general transition-based reweighting analysis method (TRAM), a statistically optimal approach to integrate both unbiased and biased molecular dynamics simulations, such as umbrella sampling or replica exchange. TRAM estimates a multiensemble Markov model (MEMM) with full thermodynamic and kinetic information at all ensembles. The approach combines the benefits of Markov state models—clustering of high-dimensional spaces and modeling of complex many-state systems—with those of the multistate Bennett acceptance ratio of exploiting biased or high-temperature ensembles to accelerate rare-event sampling. TRAM does not depend on any rate model in addition to the widely used Markov state model approximation, but uses only fundamental relations such as detailed balance and binless reweighting of configurations between ensembles. Previous methods, including the multistate Bennett acceptance ratio, discrete TRAM, and Markov state models are special cases and can be derived from the TRAM equations. TRAM is demonstrated by efficiently computing MEMMs in cases where other estimators break down, including the full thermodynamics and rare-event kinetics from high-dimensional simulation data of an all-atom protein–ligand binding model. PMID:27226302

  17. The impact of differences in EQ-5D and SF-6D utility scores on the acceptability of cost-utility ratios: results across five trial-based cost-utility studies.

    PubMed

    Joore, Manuela; Brunenberg, Danielle; Nelemans, Patricia; Wouters, Emiel; Kuijpers, Petra; Honig, Adriaan; Willems, Danielle; de Leeuw, Peter; Severens, Johan; Boonen, Annelies

    2010-01-01

    This article investigates whether differences in utility scores based on the EQ-5D and the SF-6D have impact on the incremental cost-utility ratios in five distinct patient groups. We used five empirical data sets of trial-based cost-utility studies that included patients with different disease conditions and severity (musculoskeletal disease, cardiovascular pulmonary disease, and psychological disorders) to calculate differences in quality-adjusted life-years (QALYs) based on EQ-5D and SF-6D utility scores. We compared incremental QALYs, incremental cost-utility ratios, and the probability that the incremental cost-utility ratio was acceptable within and across the data sets. We observed small differences in incremental QALYs, but large differences in the incremental cost-utility ratios and in the probability that these ratios were acceptable at a given threshold, in the majority of the presented cost-utility analyses. More specifically, in the patient groups with relatively mild health conditions the probability of acceptance of the incremental cost-utility ratio was considerably larger when using the EQ-5D to estimate utility. While in the patient groups with worse health conditions the probability of acceptance of the incremental cost-utility ratio was considerably larger when using the SF-6D to estimate utility. Much of the appeal in using QALYs as measure of effectiveness in economic evaluations is in the comparability across conditions and interventions. The incomparability of the results of cost-utility analyses using different instruments to estimate a single index value for health severely undermines this aspect and reduces the credibility of the use of incremental cost-utility ratios for decision-making.

  18. Comparison of fluorescence rejection methods of baseline correction and shifted excitation Raman difference spectroscopy

    NASA Astrophysics Data System (ADS)

    Cai, Zhijian; Zou, Wenlong; Wu, Jianhong

    2017-10-01

    Raman spectroscopy has been extensively used in biochemical tests, explosive detection, food additive and environmental pollutants. However, fluorescence disturbance brings a big trouble to the applications of portable Raman spectrometer. Currently, baseline correction and shifted-excitation Raman difference spectroscopy (SERDS) methods are the most prevailing fluorescence suppressing methods. In this paper, we compared the performances of baseline correction and SERDS methods, experimentally and simulatively. Through the comparison, it demonstrates that the baseline correction can get acceptable fluorescence-removed Raman spectrum if the original Raman signal has good signal-to-noise ratio, but it cannot recover the small Raman signals out of large noise background. By using SERDS method, the Raman signals, even very weak compared to fluorescence intensity and noise level, can be clearly extracted, and the fluorescence background can be completely rejected. The Raman spectrum recovered by SERDS has good signal to noise ratio. It's proved that baseline correction is more suitable for large bench-top Raman system with better quality or signal-to-noise ratio, while the SERDS method is more suitable for noisy devices, especially the portable Raman spectrometers.

  19. Novel spectrophotometric determination of flumethasone pivalate and clioquinol in their binary mixture and pharmaceutical formulation.

    PubMed

    Abdel-Aleem, Eglal A; Hegazy, Maha A; Sayed, Nour W; Abdelkawy, M; Abdelfatah, Rehab M

    2015-02-05

    This work is concerned with development and validation of three simple, specific, accurate and precise spectrophotometric methods for determination of flumethasone pivalate (FP) and clioquinol (CL) in their binary mixture and ear drops. Method A is a ratio subtraction spectrophotometric one (RSM). Method B is a ratio difference spectrophotometric one (RDSM), while method C is a mean center spectrophotometric one (MCR). The calibration curves are linear over the concentration range of 3-45 μg/mL for FP, and 2-25 μg/mL for CL. The specificity of the developed methods was assessed by analyzing different laboratory prepared mixtures of the FP and CL. The three methods were validated as per ICH guidelines; accuracy, precision and repeatability are found to be within the acceptable limits. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. A mechanism to derive more truthful willingness to accept values for renewable energy systems.

    PubMed

    Radmehr, Mehrshad; Willis, Ken; Metcalf, Hugh

    2018-01-01

    This paper examines and compares households' willingness to accept (WTA)/willingness to pay (WTP) ratio for solar power equipment on their premises through both a novel experimental approach and conventional techniques. The experimental approach was administered by using a Becker-DeGroot-Marschak method and cheap talk, with open-ended questions of WTA/WTP. The results were quite striking. The ratio for the incentivised approach was 1.08:1; whereas for the conventional approach it was 3.5:1. The findings suggest that the hypothesis that WTP equals WTA cannot be rejected for the incentivised mechanism, and it appears to control for the individual's strategic behaviour bias as a treatment against over-estimating WTA and under-estimating WTP. The findings also provide some policy implications for Northern Cyprus: the government can set lower financial incentives to increase the solar power installed capacity on the island.

  1. Comparative study between recent methods manipulating ratio spectra and classical methods based on two-wavelength selection for the determination of binary mixture of antazoline hydrochloride and tetryzoline hydrochloride.

    PubMed

    Abdel-Halim, Lamia M; Abd-El Rahman, Mohamed K; Ramadan, Nesrin K; El Sanabary, Hoda F A; Salem, Maissa Y

    2016-04-15

    A comparative study was developed between two classical spectrophotometric methods (dual wavelength method and Vierordt's method) and two recent methods manipulating ratio spectra (ratio difference method and first derivative of ratio spectra method) for simultaneous determination of Antazoline hydrochloride (AN) and Tetryzoline hydrochloride (TZ) in their combined pharmaceutical formulation and in the presence of benzalkonium chloride as a preservative without preliminary separation. The dual wavelength method depends on choosing two wavelengths for each drug in a way so that the difference in absorbance at those two wavelengths is zero for the other drug. While Vierordt's method, is based upon measuring the absorbance and the absorptivity values of the two drugs at their λ(max) (248.0 and 219.0 nm for AN and TZ, respectively), followed by substitution in the corresponding Vierordt's equation. Recent methods manipulating ratio spectra depend on either measuring the difference in amplitudes of ratio spectra between 255.5 and 269.5 nm for AN and 220.0 and 273.0 nm for TZ in case of ratio difference method or computing first derivative of the ratio spectra for each drug then measuring the peak amplitude at 250.0 nm for AN and at 224.0 nm for TZ in case of first derivative of ratio spectrophotometry. The specificity of the developed methods was investigated by analyzing different laboratory prepared mixtures of the two drugs. All methods were applied successfully for the determination of the selected drugs in their combined dosage form proving that the classical spectrophotometric methods can still be used successfully in analysis of binary mixture using minimal data manipulation rather than recent methods which require relatively more steps. Furthermore, validation of the proposed methods was performed according to ICH guidelines; accuracy, precision and repeatability are found to be within the acceptable limits. Statistical studies showed that the methods can be competitively applied in quality control laboratories. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Bennett's acceptance ratio and histogram analysis methods enhanced by umbrella sampling along a reaction coordinate in configurational space.

    PubMed

    Kim, Ilsoo; Allen, Toby W

    2012-04-28

    Free energy perturbation, a method for computing the free energy difference between two states, is often combined with non-Boltzmann biased sampling techniques in order to accelerate the convergence of free energy calculations. Here we present a new extension of the Bennett acceptance ratio (BAR) method by combining it with umbrella sampling (US) along a reaction coordinate in configurational space. In this approach, which we call Bennett acceptance ratio with umbrella sampling (BAR-US), the conditional histogram of energy difference (a mapping of the 3N-dimensional configurational space via a reaction coordinate onto 1D energy difference space) is weighted for marginalization with the associated population density along a reaction coordinate computed by US. This procedure produces marginal histograms of energy difference, from forward and backward simulations, with higher overlap in energy difference space, rendering free energy difference estimations using BAR statistically more reliable. In addition to BAR-US, two histogram analysis methods, termed Bennett overlapping histograms with US (BOH-US) and Bennett-Hummer (linear) least square with US (BHLS-US), are employed as consistency and convergence checks for free energy difference estimation by BAR-US. The proposed methods (BAR-US, BOH-US, and BHLS-US) are applied to a 1-dimensional asymmetric model potential, as has been used previously to test free energy calculations from non-equilibrium processes. We then consider the more stringent test of a 1-dimensional strongly (but linearly) shifted harmonic oscillator, which exhibits no overlap between two states when sampled using unbiased Brownian dynamics. We find that the efficiency of the proposed methods is enhanced over the original Bennett's methods (BAR, BOH, and BHLS) through fast uniform sampling of energy difference space via US in configurational space. We apply the proposed methods to the calculation of the electrostatic contribution to the absolute solvation free energy (excess chemical potential) of water. We then address the controversial issue of ion selectivity in the K(+) ion channel, KcsA. We have calculated the relative binding affinity of K(+) over Na(+) within a binding site of the KcsA channel for which different, though adjacent, K(+) and Na(+) configurations exist, ideally suited to these US-enhanced methods. Our studies demonstrate that the significant improvements in free energy calculations obtained using the proposed methods can have serious consequences for elucidating biological mechanisms and for the interpretation of experimental data.

  3. The TG/HDL-C Ratio Might Be a Surrogate for Insulin Resistance in Chinese Nonobese Women

    PubMed Central

    He, Jiyun; He, Sen; Liu, Kai; Wang, Yong; Shi, Di

    2014-01-01

    Obejective. To examine the discriminatory power of triglyceride (TG) and triglyceride to high-density lipoprotein cholesterol ratio (TG/HDL-C) for insulin resistance (IR) in a normoglycaemic Chinese population. Methods. The data were collected from 711 individuals. The normoglycaemic individuals were eventually included in the study (n = 533, age: 62.8 ± 6.6 years, male: 56.8%), who were with a fasting plasma glucose < 6.1 mmol/L and without a history of diabetes. IR was defined as the upper quintile (≥1.6) of homeostasis model assessment of IR. Area under the receiver operating characteristic curve (AROC) was used to examine the discriminatory power. Results. The discriminatory power of TG/HDL-C for IR was acceptable in women with a BMI < 24 kg/m2 or waist circumference < 80 cm (AROCs: 0.718 and 0.713, resp.); however, the discriminatory power was not acceptable in the obese women. TG/HDL-C was not an acceptable marker of IR in men. The discriminatory power of TG for IR was not acceptable in both men and women. Conclusions. The discriminatory power of TG/HDL-C for IR differs by gender and obesity index in the normoglycaemic Chinese population, and TG/HDL-C could discriminate IR in the nonobese and normoglycaemic women. PMID:25136362

  4. Business Profile of Boat Lift Net and Stationary Lift Net Fishing Gear in Morodemak Waters Central Java

    NASA Astrophysics Data System (ADS)

    Hapsari, Trisnani D.; Jayanto, Bogi B.; Fitri, Aristi D. P.; Triarso, I.

    2018-02-01

    Lift net is one of the fishing gears that is used widely in the Morodemak coastal fishing port (PPP) for catching pelagic fish. The yield of fish captured by these fishing gear has high economic value, such as fish belt (Trichiurus sp), squids (Loligo sp) and anchovies (Stelophorus sp). The aims of this research were to determine the technical aspects of boat lift net and stationary lift net fishing gear in Morodemak Waters Demak Regency; to find out the financial aspect of those fishing gears and to analyze the financial feasibility by counting PP, NPV, IRR, and B/C ratio criteria. This research used case study method with descriptive analysis. The sampling method was purposive sampling with 22 fishermen as respondents. The result of the research showed that the average of boat lift net acceptance was Rp 388,580,000. The financial analysis of fisheries boat lift net with the result of NPV Rp 836,149,272, PP 2.44 years, IRR value 54%, and B/C ratio 1.73. The average of stationary lift net acceptance was Rp 27,750,000. The financial analysis lift net with the result of NPV Rp 37,937,601; PP 1.96 years, IRR value 86%, and B/C ratio 1.32. This research had a positive NPV value, B/C ratio >1, and IRR > discount rate (12 %). This study concluded that the fishery business of boat lift net and stationary lift net in Morodemak coastal fishing port (PPP) was worth running.

  5. Quantitative Analysis of Drugs with Highly Different Concentrations of Pharmaceutical Components Using Spectral Subtraction Techniques

    NASA Astrophysics Data System (ADS)

    Ayoub, B. M.

    2017-11-01

    Two simple spectrophotometric methods were developed for determination of empagliflozin and metformin by manipulating their ratio spectra with application on a recently approved pharmaceutical combination, Synjardy® tablets. A spiking technique was used to increase the concentration of empagliflozin after extraction from the tablets to allow its simultaneous determination with metformin. Validation parameters according to ICH guidelines were acceptable over the concentration range of 2-12 μg/mL for both drugs using constant multiplication and spectrum subtraction methods. The optimized methods are suitable for QC labs.

  6. Computation of geometric representation of novel spectrophotometric methods used for the analysis of minor components in pharmaceutical preparations.

    PubMed

    Lotfy, Hayam M; Saleh, Sarah S; Hassan, Nagiba Y; Salem, Hesham

    2015-01-01

    Novel spectrophotometric methods were applied for the determination of the minor component tetryzoline HCl (TZH) in its ternary mixture with ofloxacin (OFX) and prednisolone acetate (PA) in the ratio of (1:5:7.5), and in its binary mixture with sodium cromoglicate (SCG) in the ratio of (1:80). The novel spectrophotometric methods determined the minor component (TZH) successfully in the two selected mixtures by computing the geometrical relationship of either standard addition or subtraction. The novel spectrophotometric methods are: geometrical amplitude modulation (GAM), geometrical induced amplitude modulation (GIAM), ratio H-point standard addition method (RHPSAM) and compensated area under the curve (CAUC). The proposed methods were successfully applied for the determination of the minor component TZH below its concentration range. The methods were validated as per ICH guidelines where accuracy, repeatability, inter-day precision and robustness were found to be within the acceptable limits. The results obtained from the proposed methods were statistically compared with official ones where no significant difference was observed. No difference was observed between the obtained results when compared to the reported HPLC method, which proved that the developed methods could be alternative to HPLC techniques in quality control laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Mitigate the impact of transmitter finite extinction ratio using K-means clustering algorithm for 16QAM signal

    NASA Astrophysics Data System (ADS)

    Yu, Miao; Li, Yan; Shu, Tong; Zhang, Yifan; Hong, Xiaobin; Qiu, Jifang; Zuo, Yong; Guo, Hongxiang; Li, Wei; Wu, Jian

    2018-02-01

    A method of recognizing 16QAM signal based on k-means clustering algorithm is proposed to mitigate the impact of transmitter finite extinction ratio. There are pilot symbols with 0.39% overhead assigned to be regarded as initial centroids of k-means clustering algorithm. Simulation result in 10 GBaud 16QAM system shows that the proposed method obtains higher precision of identification compared with traditional decision method for finite ER and IQ mismatch. Specially, the proposed method improves the required OSNR by 5.5 dB, 4.5 dB, 4 dB and 3 dB at FEC limit with ER= 12 dB, 16 dB, 20 dB and 24 dB, respectively, and the acceptable bias error and IQ mismatch range is widened by 767% and 360% with ER =16 dB, respectively.

  8. Design and analysis of a curved cylindrical Fresnel lens that produces high irradiance uniformity on the solar cell.

    PubMed

    González, Juan C

    2009-04-10

    A new type of convex Fresnel lens for linear photovoltaic concentration systems is presented. The lens designed with this method reaches 100% of geometrical optical efficiency, and the ratio (Aperture area)/(Receptor area) is up to 75% of the theoretical limit. The main goal of the design is high uniformity of the radiation on the cell surface for each input angle inside the acceptance. The ratio between the maximum and the minimum irradiance on points of the solar cell is less than 2. The lens has been designed with the simultaneous multiple surfaces (SMS) method of nonimaging optics, and ray tracing techniques have been used to characterize its performance for linear symmetry systems.

  9. Enhanced Sampling in Free Energy Calculations: Combining SGLD with the Bennett's Acceptance Ratio and Enveloping Distribution Sampling Methods.

    PubMed

    König, Gerhard; Miller, Benjamin T; Boresch, Stefan; Wu, Xiongwu; Brooks, Bernard R

    2012-10-09

    One of the key requirements for the accurate calculation of free energy differences is proper sampling of conformational space. Especially in biological applications, molecular dynamics simulations are often confronted with rugged energy surfaces and high energy barriers, leading to insufficient sampling and, in turn, poor convergence of the free energy results. In this work, we address this problem by employing enhanced sampling methods. We explore the possibility of using self-guided Langevin dynamics (SGLD) to speed up the exploration process in free energy simulations. To obtain improved free energy differences from such simulations, it is necessary to account for the effects of the bias due to the guiding forces. We demonstrate how this can be accomplished for the Bennett's acceptance ratio (BAR) and the enveloping distribution sampling (EDS) methods. While BAR is considered among the most efficient methods available for free energy calculations, the EDS method developed by Christ and van Gunsteren is a promising development that reduces the computational costs of free energy calculations by simulating a single reference state. To evaluate the accuracy of both approaches in connection with enhanced sampling, EDS was implemented in CHARMM. For testing, we employ benchmark systems with analytical reference results and the mutation of alanine to serine. We find that SGLD with reweighting can provide accurate results for BAR and EDS where conventional molecular dynamics simulations fail. In addition, we compare the performance of EDS with other free energy methods. We briefly discuss the implications of our results and provide practical guidelines for conducting free energy simulations with SGLD.

  10. Development of acceptance criteria for batches of silane primer for external tank thermal protection system bonding applications

    NASA Technical Reports Server (NTRS)

    Mikes, F.

    1985-01-01

    Concluding tests for the thermogravimetric and FTIR analyses of DC 1200 silane primers are discussed as well as methods for HPLC and GC analyses and for determining titanium and silicon by atomic absorption spectroscopy. Tables summarizes results obtained for residue, ash, titanium, silicone, Si/Ti ratio, OH-absorption, the lap-shear test, and the GC headspace for alcohols.

  11. Effects of castration age, protein level and lysine/methionine ratio in the diet on colour, lipid oxidation and meat acceptability of intensively reared Friesian steers.

    PubMed

    Prado, I N; Campo, M M; Muela, E; Valero, M V; Catalan, O; Olleta, J L; Sañudo, C

    2015-08-01

    A total of 64 intensively reared Friesian steers were used in a 2×2×2 design to study the effects of age of castration (15 days old v. 5 months old), dietary protein level (14.6% v. 16.8%; DM basis) and lysine/methionine (lys/met) ratio (3.0 v. 3.4) on meat quality. The lys/met ratio of 3.0 was reached with supplementation of protected methionine. Animals were slaughtered at a live weight of 443.5 ± 26.2 kg at around 12 months of age. Colour and lipid oxidation were measured in the longissimus thoracis muscle throughout the 14 days of display under modified atmospheric and commercial display conditions. A panel of 17 consumers assessed daily the visual acceptability of the meat on display. A consumer acceptability eating test was also performed with 120 consumers in meat aged for 7 days under vacuum conditions. Lipid oxidation was not influenced by castration age and the protein level in the diet. Castration age did not affect meat colour, but meat from the low protein level diet and the low lys/met ratio showed higher redness (a*) from 3 days of display onwards. Nevertheless, from 6 days onwards, consumer visual acceptability was below the level of acceptance in all treatments, and even from 5 days onwards in those animals that underwent early castration and were fed either a high protein diet or a combination diet low in protein content and high in lys/met ratio. The best accepted treatments throughout the display period were those from late castrated animals fed a low protein diet, probably related to other visual aspects. However, the best accepted meat after consumption was that from late castrated animals fed high protein and high lys/met. The addition of protected methionine to reach lys/met levels of 3.0 did not improve beef acceptability, with the high protein diet being preferred by consumers in terms of palatability in late castrated animals.

  12. Impact of uncertainty on cost-effectiveness analysis of medical strategies: the case of high-dose chemotherapy for breast cancer patients.

    PubMed

    Marino, Patricia; Siani, Carole; Roché, Henri; Moatti, Jean-Paul

    2005-01-01

    The object of this study was to determine, taking into account uncertainty on cost and outcome parameters, the cost-effectiveness of high-dose chemotherapy (HDC) compared with conventional chemotherapy for advanced breast cancer patients. An analysis was conducted for 300 patients included in a randomized clinical trial designed to evaluate the benefits, in terms of disease-free survival and overall survival, of adding a single course of HDC to a four-cycle conventional-dose chemotherapy for breast cancer patients with axillary lymph node invasion. Costs were estimated from a detailed observation of physical quantities consumed, and the Kaplan-Meier method was used to evaluate mean survival times. Incremental cost-effectiveness ratios were evaluated successively considering disease-free survival and overall survival outcomes. Handling of uncertainty consisted in construction of confidence intervals for these ratios, using the truncated Fieller method. The cost per disease-free life year gained was evaluated at 13,074 Euros, a value that seems to be acceptable to society. However, handling uncertainty shows that the upper bound of the confidence interval is around 38,000 Euros, which is nearly three times higher. Moreover, as no difference was demonstrated in overall survival between treatments, cost-effectiveness analysis, that is a cost minimization, indicated that the intensive treatment is a dominated strategy involving an extra cost of 7,400 Euros, for no added benefit. Adding a single course of HDC led to a clinical benefit in terms of disease-free survival for an additional cost that seems to be acceptable, considering the point estimate of the ratio. However, handling uncertainty indicates a maximum ratio for which conclusions have to be discussed.

  13. ACCEPT 2: A public library of cluster properties

    NASA Astrophysics Data System (ADS)

    Donahue, Megan

    2012-09-01

    The current public ACCEPT database of cluster properties includes radial profiles of Tx, n_elec, entropy, and cooling time. We propose to more than double the current number of clusters in ACCEPT and to expand the current suite of properties to include uniformly measured profiles of gas mass and hydrostatic equilibrium mass along with signatures of dynamical relaxation (centroid shift, power ratios, surface brightness concentration, temperature ratios) and global quantities such as core-excised Tx, Lx, and metallicities. We will explore the relationship between cool cores and dynamical relaxation, the reliability of hydrostatic mass profiles, and the dependence of the gas mass fraction on halo mass, redshift, and the degree of relaxation. ACCEPT2 will enable further community science.

  14. A Note on the Determination of "Acceptable" Performance in Thorndike's Standard of Fair Selection.

    ERIC Educational Resources Information Center

    Brown, Charles

    1980-01-01

    The determination of acceptable performance in Thorndike's constant ratio standard of fair selection is considered. It is shown that suitable choice of acceptable performance can make any minority-majority selection disparity consistent with Thorndike's standard. A rule for determining acceptable performance which avoids the Petersen-Novick…

  15. Establishment of a Method for Measuring Antioxidant Capacity in Urine, Based on Oxidation Reduction Potential and Redox Couple I2/KI

    PubMed Central

    Cao, Tinghui; He, Min; Bai, Tianyu

    2016-01-01

    Objectives. To establish a new method for determination of antioxidant capacity of human urine based on the redox couple I2/KI and to evaluate the redox status of healthy and diseased individuals. Methods. The method was based on the linear relationship between oxidation reduction potential (ORP) and logarithm of concentration ratio of I2/KI. ORP of a solution with a known concentration ratio of I2/KI will change when reacted with urine. To determine the accuracy of the method, both vitamin C and urine were reacted separately with I2/KI solution. The new method was compared with the traditional method of iodine titration and then used to measure the antioxidant capacity of urine samples from 30 diabetic patients and 30 healthy subjects. Results. A linear relationship was found between logarithm of concentration ratio of I2/KI and ORP (R 2 = 0.998). Both vitamin C and urine concentration showed a linear relationship with ORP (R 2 = 0.994 and 0.986, resp.). The precision of the method was in the acceptable range and results of two methods had a linear correlation (R 2 = 0.987). Differences in ORP values between diabetic group and control group were statistically significant (P < 0.05). Conclusions. A new method for measuring the antioxidant capacity of clinical urine has been established. PMID:28115919

  16. Solar disinfection of water for diarrhoeal prevention in southern India

    PubMed Central

    Rose, A; Roy, S; Abraham, V; Holmgren, G; George, K; Balraj, V; Abraham, S; Muliyil, J; Joseph, A; Kang, G

    2006-01-01

    Aims To evaluate the efficacy and acceptability of solar irradiation in the prevention of diarrhoeal morbidity in children under 5 years of age, in an urban slum in Vellore, Tamil Nadu. Methods A total of 100 children were assigned to receive drinking water that had been subjected to solar disinfection in polyethylene terephthalate bottles. One hundred age and sex matched controls were also selected. Both groups were followed by weekly home visits for a period of six months for any diarrhoeal morbidity. At the end of the follow up period, the acceptability of the intervention was assessed by interviews, questionnaires, and focus group discussions. Results There was significant reduction in the incidence, duration, and severity of diarrhoea in children receiving solar disinfected water, despite 86% of the children drinking water other than that treated by the intervention. The incidence of diarrhoea in the intervention group was 1.7 per child‐year, and among controls 2.7 per child‐year, with an incidence rate ratio of 0.64 (95% CI −0.48 to 0.86). The risk of diarrhoea was reduced by 40% by using solar disinfection. In qualitative evaluation of acceptability, most women felt that solar disinfection was a feasible and sustainable method of disinfecting water. Conclusions Solar disinfection of water is an inexpensive, effective, and acceptable method of increasing water safety in a resource limited environment, and can significantly decrease diarrhoeal morbidity in children. PMID:16403847

  17. The subxiphoid view cannot replace the apical view for transthoracic echocardiographic assessment of hemodynamic status

    PubMed Central

    2013-01-01

    Introduction This prospective study aimed to assess whether use of the subxiphoid acoustic window in transthoracic echocardiography (TTE) can be an accurate alternative in the absence of an apical view to assess hemodynamic parameters. Methods This prospective study took place in a teaching hospital medical ICU. Over a 4-month period, TTE was performed in patients admitted for more than 24 hours. Two operators rated the quality of parasternal, apical, and subxiphoid acoustic windows as Excellent, Good, Acceptable, Poor, or No image. In the subpopulation presenting adequate (rated as acceptable or higher) apical and subxiphoid views, we compared the left ventricular ejection fraction (LVEF), the ratio between right and left ventricular end-diastolic areas (RVEDA/LVEDA), the ratio between early and late mitral inflow on pulsed Doppler (E/A ratio), the aortic velocity time integral (Ao VTI), and the ratio between early mitral inflow and displacement of the mitral annulus on tissue Doppler imaging (E/Ea ratio). Results An adequate apical view was obtained in 80%, and an adequate subxiphoid view was obtained in 63% of the 107 patients included. Only 5% of patients presented an adequate subxiphoid view without an adequate apical view. In the subpopulation of patients with adequate apical and subxiphoid windows (n = 65), LVEF, E/A, and RVEDA/LVEDA were comparable on both views, and were strongly correlated (r > 0.80) with acceptable biases and precision. However, the Ao VTI and the E/Ea ratio were lower on the subxiphoid view than on the apical view (18 ± 5 versus 16 ± 5 cm and 9.6 ± 4.6 versus 7.6 ± 4 cm, respectively, P = 0.001 for both). Conclusions An adequate TTE subxiphoid window was obtained in fewer than two thirds of ICU patients. In addition to the classic indication for the subxiphoid window to study the vena cava and pericardium, this view can be used to study right and left ventricular morphology and function, but does not provide accurate hemodynamic Doppler information. ICU echocardiographers should therefore record both apical and subxiphoid views to assess comprehensively the cardiac function and hemodynamic status. PMID:24004960

  18. Hepatoblastoma Biology Using Isotope Ratio Mass Spectrometry: Utility of a Unique Technique for the Analysis of Oncological Specimens.

    PubMed

    Taran, Katarzyna; Frączek, Tomasz; Sitkiewicz, Anna; Sikora-Szubert, Anita; Kobos, Józef; Paneth, Piotr

    2016-07-07

    Hepatoblastoma is the most common primary liver tumor in children. However, it occurs rarely, with an incidence of 0.5-1.5 cases per million children. There is no clear explanation of the relationship between clinicopathologic features, therapy, and outcome in hepatoblastoma cases, so far. One of the most widely accepted prognostic factors in hepatoblastoma is histology of the tumor. The aim of the study was to determine the potential differences in biology of hepatoblastoma histological subtypes at the atomic level using the unique method of isotope ratio mass spectrometry, which is especially valuable in examination of small groups of biological samples. Twenty-four measurements of nitrogen stable isotope ratio, carbon stable isotope ratio and total carbon to nitrogen mass ratio in fetal and embryonal hepatoblastoma tissue were performed using a Sercon 20-22 Continuous Flow Isotope Ratio Mass Spectrometer (CF-IRMS) coupled with a Sercon SL elemental analyzer for simultaneous carbon-nitrogen-sulfur (NCS) analysis. A difference of about 1.781‰ in stable nitrogen isotope 15N/14N ratio was found between examined hepatoblastoma histological subtypes. The prognosis in liver tumors cases in children may be challenging particularly because of the lack of versatile methods of its evaluation. Isotope ratio mass spectrometry allows one to determine the difference between hepatoblastoma histological subtypes and clearly indicates the cases with the best outcome.

  19. Photoacoustic tomography from weak and noisy signals by using a pulse decomposition algorithm in the time-domain.

    PubMed

    Liu, Liangbing; Tao, Chao; Liu, XiaoJun; Deng, Mingxi; Wang, Senhua; Liu, Jun

    2015-10-19

    Photoacoustic tomography is a promising and rapidly developed methodology of biomedical imaging. It confronts an increasing urgent problem to reconstruct the image from weak and noisy photoacoustic signals, owing to its high benefit in extending the imaging depth and decreasing the dose of laser exposure. Based on the time-domain characteristics of photoacoustic signals, a pulse decomposition algorithm is proposed to reconstruct a photoacoustic image from signals with low signal-to-noise ratio. In this method, a photoacoustic signal is decomposed as the weighted summation of a set of pulses in the time-domain. Images are reconstructed from the weight factors, which are directly related to the optical absorption coefficient. Both simulation and experiment are conducted to test the performance of the method. Numerical simulations show that when the signal-to-noise ratio is -4 dB, the proposed method decreases the reconstruction error to about 17%, in comparison with the conventional back-projection method. Moreover, it can produce acceptable images even when the signal-to-noise ratio is decreased to -10 dB. Experiments show that, when the laser influence level is low, the proposed method achieves a relatively clean image of a hair phantom with some well preserved pattern details. The proposed method demonstrates imaging potential of photoacoustic tomography in expanding applications.

  20. Surrogate outcomes: experiences at the Common Drug Review

    PubMed Central

    2013-01-01

    Background Surrogate outcomes are a significant challenge in drug evaluation for health technology assessment (HTA) agencies. The research objectives were to: identify factors associated with surrogate use and acceptability in Canada’s Common Drug Review (CDR) recommendations, and compare the CDR with other HTA or regulatory agencies regarding surrogate concerns. Methods Final recommendations were identified from CDR inception (September 2003) to December 31, 2010. Recommendations were classified by type of outcome (surrogate, final, other) and acceptability of surrogates (determined by the presence/absence of statements of concern regarding surrogates). Descriptive and statistical analyses examined factors related to surrogate use and acceptability. For thirteen surrogate-based submissions, recommendations from international HTA and regulatory agencies were reviewed for statements about surrogate acceptability. Results Of 156 final recommendations, 68 (44%) involved surrogates. The overall ‘do not list’ (DNL) rate was 48%; the DNL rate for surrogates was 41% (p = 0.175). The DNL rate was 64% for non-accepted surrogates (n = 28) versus 25% for accepted surrogates (odds ratio 5.4, p = 0.002). Clinical uncertainty, use of economic evidence over price alone, and a premium price were significantly associated with non-accepted surrogates. Surrogates were used most commonly for HIV, diabetes, rare diseases, cardiovascular disease and cancer. For the subset of drugs studied, other HTA agencies did not express concerns for most recommendations, while regulatory agencies frequently stated surrogate acceptance. Conclusions The majority of surrogates were accepted at the CDR. Non-accepted surrogates were significantly associated with clinical uncertainty and a DNL recommendation. There was inconsistency of surrogate acceptability across several international agencies. Stakeholders should consider collaboratively establishing guidelines on the use, validation, and acceptability of surrogates. PMID:24341379

  1. Skill in Retrievals

    NASA Technical Reports Server (NTRS)

    Aumann, Hartmut H.; Manning, Evan

    2008-01-01

    Retrieval Skill quantifies the ability of one retrieval from a sounder to be more accurate than the best forecast relative to another with the same of another sounder. This is summarized using a Retrieval Anomaly Skill Score (RASS) which is the cor (retrieved-background, truth-background) * sqrt(f), Where f is defined as the ratio of accepted to the possible retrievals. Charts show various features and comparisons of RASS to other methods of retrieval.

  2. Vibration characteristics of teak wood filled steel tubes

    NASA Astrophysics Data System (ADS)

    Danawade, Bharatesh Adappa; Malagi, Ravindra Rachappa

    2018-05-01

    The objective of this paper is to determine fundamental frequency and damping ratio of teak wood filled steel tubes. Mechanically bonded teak wood filled steel tubes have been evaluated by experimental impact hammer test using modal analysis. The results of impact hammer test were verified and validated by finite element tool ANSYS using harmonic analysis. The error between the two methods was observed to be within acceptable limit.

  3. Modeling topology formation during laser ablation

    NASA Astrophysics Data System (ADS)

    Hodapp, T. W.; Fleming, P. R.

    1998-07-01

    Micromachining high aspect-ratio structures can be accomplished through ablation of surfaces with high-powered lasers. Industrial manufacturers now use these methods to form complex and regular surfaces at the 10-1000 μm feature size range. Despite its increasingly wide acceptance on the manufacturing floor, the underlying photochemistry of the ablation mechanism, and hence the dynamics of the machining process, is still a question of considerable debate. We have constructed a computer model to investigate and predict the topological formation of ablated structures. Qualitative as well as quantitative agreement with excimer-laser machined polyimide substrates has been demonstrated. This model provides insights into the drilling process for high-aspect-ratio holes.

  4. Deep Compaction Control of Sandy Soils

    NASA Astrophysics Data System (ADS)

    Bałachowski, Lech; Kurek, Norbert

    2015-02-01

    Vibroflotation, vibratory compaction, micro-blasting or heavy tamping are typical improvement methods for the cohesionless deposits of high thickness. The complex mechanism of deep soil compaction is related to void ratio decrease with grain rearrangements, lateral stress increase, prestressing effect of certain number of load cycles, water pressure dissipation, aging and other effects. Calibration chamber based interpretation of CPTU/DMT can be used to take into account vertical and horizontal stress and void ratio effects. Some examples of interpretation of soundings in pre-treated and compacted sands are given. Some acceptance criteria for compaction control are discussed. The improvement factors are analysed including the normalised approach based on the soil behaviour type index.

  5. Development of a nonlinear vortex method

    NASA Technical Reports Server (NTRS)

    Kandil, O. A.

    1982-01-01

    Steady and unsteady Nonliner Hybrid Vortex (NHV) method, for low aspect ratio wings at large angles of attack, is developed. The method uses vortex panels with first-order vorticity distribution (equivalent to second-order doublet distribution) to calculate the induced velocity in the near field using closed form expressions. In the far field, the distributed vorticity is reduced to concentrated vortex lines and the simpler Biot-Savart's law is employed. The method is applied to rectangular wings in steady and unsteady flows without any restriction on the order of magnitude of the disturbances in the flow field. The numerical results show that the method accurately predicts the distributed aerodynamic loads and that it is of acceptable computational efficiency.

  6. The application of Gaussian mixture models for signal quantification in MALDI-TOF mass spectrometry of peptides.

    PubMed

    Spainhour, John Christian G; Janech, Michael G; Schwacke, John H; Velez, Juan Carlos Q; Ramakrishnan, Viswanathan

    2014-01-01

    Matrix assisted laser desorption/ionization time-of-flight (MALDI-TOF) coupled with stable isotope standards (SIS) has been used to quantify native peptides. This peptide quantification by MALDI-TOF approach has difficulties quantifying samples containing peptides with ion currents in overlapping spectra. In these overlapping spectra the currents sum together, which modify the peak heights and make normal SIS estimation problematic. An approach using Gaussian mixtures based on known physical constants to model the isotopic cluster of a known compound is proposed here. The characteristics of this approach are examined for single and overlapping compounds. The approach is compared to two commonly used SIS quantification methods for single compound, namely Peak Intensity method and Riemann sum area under the curve (AUC) method. For studying the characteristics of the Gaussian mixture method, Angiotensin II, Angiotensin-2-10, and Angiotenisn-1-9 and their associated SIS peptides were used. The findings suggest, Gaussian mixture method has similar characteristics as the two methods compared for estimating the quantity of isolated isotopic clusters for single compounds. All three methods were tested using MALDI-TOF mass spectra collected for peptides of the renin-angiotensin system. The Gaussian mixture method accurately estimated the native to labeled ratio of several isolated angiotensin peptides (5.2% error in ratio estimation) with similar estimation errors to those calculated using peak intensity and Riemann sum AUC methods (5.9% and 7.7%, respectively). For overlapping angiotensin peptides, (where the other two methods are not applicable) the estimation error of the Gaussian mixture was 6.8%, which is within the acceptable range. In summary, for single compounds the Gaussian mixture method is equivalent or marginally superior compared to the existing methods of peptide quantification and is capable of quantifying overlapping (convolved) peptides within the acceptable margin of error.

  7. Fish fins as non-lethal surrogates for muscle tissues in freshwater food web studies using stable isotopes.

    PubMed

    Hette Tronquart, Nicolas; Mazeas, Laurent; Reuilly-Manenti, Liana; Zahm, Amandine; Belliard, Jérôme

    2012-07-30

    Dorsal white muscle is the standard tissue analysed in fish trophic studies using stable isotope analyses. However, sampling white muscle often implies the sacrifice of fish. Thus, we examined whether the non-lethal sampling of fin tissue can substitute muscle sampling in food web studies. Analysing muscle and fin δ(15)N and δ(13)C values of 466 European freshwater fish (14 species) with an elemental analyser coupled with an isotope ratio mass spectrometer, we compared the isotope values of the two tissues. Correlations between fin and muscle isotope ratios were examined for all fish together and specifically for 12 species. We further proposed four methods of assessing muscle from fin isotope ratios and estimated the errors made using these muscle surrogates. Despite significant differences between isotope values of the two tissues, fin and muscle isotopic signals are strongly correlated. Muscle values, estimated with raw fin isotope ratios (1st method), induce an error of ca. 1‰ for both isotopes. In comparison, specific (2nd method) or general (3rd method) correlations provide meaningful corrections of fin isotope ratios (errors <0.6‰). On the other hand, relationships, established for Australian tropical fish, only give poor muscle estimates (errors >0.8‰). There is little chance that a global model can be created. However, the 2nd and 3rd methods of estimating muscle values from fin isotope ratios should provide an acceptable level of error for the studies of European freshwater food web. We thus recommend that future studies use fin tissue as a non-lethal surrogate for muscle. Copyright © 2012 John Wiley & Sons, Ltd.

  8. Different applications of isosbestic points, normalized spectra and dual wavelength as powerful tools for resolution of multicomponent mixtures with severely overlapping spectra.

    PubMed

    Mohamed, Ekram H; Lotfy, Hayam M; Hegazy, Maha A; Mowaka, Shereen

    2017-05-25

    Analysis of complex mixture containing three or more components represented a challenge for analysts. New smart spectrophotometric methods have been recently evolved with no limitation. A study of different novel and smart spectrophotometric techniques for resolution of severely overlapping spectra were presented in this work utilizing isosbestic points present in different absorption spectra, normalized spectra as a divisor and dual wavelengths. A quaternary mixture of drotaverine (DRO), caffeine (CAF), paracetamol (PCT) and para-aminophenol (PAP) was taken as an example for application of the proposed techniques without any separation steps. The adopted techniques adopted of successive and progressive steps manipulating zero /or ratio /or derivative spectra. The proposed techniques includes eight novel and simple methods namely direct spectrophotometry after applying derivative transformation (DT) via multiplying by a decoding spectrum, spectrum subtraction (SS), advanced absorbance subtraction (AAS), advanced amplitude modulation (AAM), simultaneous derivative ratio (S 1 DD), advanced ratio difference (ARD), induced ratio difference (IRD) and finally double divisor-ratio difference-dual wavelength (DD-RD-DW) methods. The proposed methods were assessed by analyzing synthetic mixtures of the studied drugs. They were also successfully applied to commercial pharmaceutical formulations without interference from other dosage form additives. The methods were validated according to the ICH guidelines, accuracy, precision, repeatability, were found to be within the acceptable limits. The proposed procedures are accurate, simple and reproducible and yet economic. They are also sensitive and selective and could be used for routine analysis of complex most of the binary, ternary and quaternary mixtures and even more complex mixtures.

  9. 76 FR 16345 - Net Worth and Equity Ratio

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-23

    ... acquisition must be measured under generally accepted accounting principles as referenced in the Act. 12 U.S.C... equity or member interest in the acquirer. Generally accepted accounting principles require this excess... generally accepted accounting principles. For low income-designated credit unions, net worth also includes...

  10. Solar disinfection of water for diarrhoeal prevention in southern India.

    PubMed

    Rose, A; Roy, S; Abraham, V; Holmgren, G; George, K; Balraj, V; Abraham, S; Muliyil, J; Joseph, A; Kang, G

    2006-02-01

    To evaluate the efficacy and acceptability of solar irradiation in the prevention of diarrhoeal morbidity in children under 5 years of age, in an urban slum in Vellore, Tamil Nadu. A total of 100 children were assigned to receive drinking water that had been subjected to solar disinfection in polyethylene terephthalate bottles. One hundred age and sex matched controls were also selected. Both groups were followed by weekly home visits for a period of six months for any diarrhoeal morbidity. At the end of the follow up period, the acceptability of the intervention was assessed by interviews, questionnaires, and focus group discussions. There was significant reduction in the incidence, duration, and severity of diarrhoea in children receiving solar disinfected water, despite 86% of the children drinking water other than that treated by the intervention. The incidence of diarrhoea in the intervention group was 1.7 per child-year, and among controls 2.7 per child-year, with an incidence rate ratio of 0.64 (95% CI -0.48 to 0.86). The risk of diarrhoea was reduced by 40% by using solar disinfection. In qualitative evaluation of acceptability, most women felt that solar disinfection was a feasible and sustainable method of disinfecting water. Solar disinfection of water is an inexpensive, effective, and acceptable method of increasing water safety in a resource limited environment, and can significantly decrease diarrhoeal morbidity in children.

  11. An image assessment study of image acceptability of the Galileo low gain antenna mission

    NASA Technical Reports Server (NTRS)

    Chuang, S. L.; Haines, R. F.; Grant, T.; Gold, Yaron; Cheung, Kar-Ming

    1994-01-01

    This paper describes a study conducted by NASA Ames Research Center (ARC) in collaboration with the Jet Propulsion Laboratory (JPL), Pasadena, California on the image acceptability of the Galileo Low Gain Antenna mission. The primary objective of the study is to determine the impact of the Integer Cosine Transform (ICT) compression algorithm on Galilean images of atmospheric bodies, moons, asteroids and Jupiter's rings. The approach involved fifteen volunteer subjects representing twelve institutions involved with the Galileo Solid State Imaging (SSI) experiment. Four different experiment specific quantization tables (q-table) and various compression stepsizes (q-factor) to achieve different compression ratios were used. It then determined the acceptability of the compressed monochromatic astronomical images as evaluated by Galileo SSI mission scientists. Fourteen different images were evaluated. Each observer viewed two versions of the same image side by side on a high resolution monitor, each was compressed using a different quantization stepsize. They were requested to select which image had the highest overall quality to support them in carrying out their visual evaluations of image content. Then they rated both images using a scale from one to five on its judged degree of usefulness. Up to four pre-selected types of images were presented with and without noise to each subject based upon results of a previously administered survey of their image preferences. Fourteen different images in seven image groups were studied. The results showed that: (1) acceptable compression ratios vary widely with the type of images; (2) noisy images detract greatly from image acceptability and acceptable compression ratios; and (3) atmospheric images of Jupiter seem to have higher compression ratios of 4 to 5 times that of some clear surface satellite images.

  12. Digit ratio (2D : 4D) moderates the impact of sexual cues on men's decisions in ultimatum games

    PubMed Central

    Van den Bergh, Bram; Dewitte, Siegfried

    2006-01-01

    Three experimental studies demonstrate that ‘sex-related cues’ impact human decision-making in ultimatum games. In the ultimatum game, two individuals divide a sum of money. The proposer offers a portion of the money to the other player, the responder. If the responder accepts the offer, the money is distributed in agreement with the proposer's offer. If the responder rejects the offer, neither player receives anything. Our studies show that exposure to pictures of sexy women or lingerie increases the likelihood of accepting unfair offers. Digit ratios of responders are reliably associated with their behaviour: males with lower digit ratios are more likely to reject an unfair split in neutral contexts, but more likely to accept unfair offers in sex-related contexts. PMID:16846918

  13. High temporal resolution dynamic contrast-enhanced MRI using compressed sensing-combined sequence in quantitative renal perfusion measurement.

    PubMed

    Chen, Bin; Zhao, Kai; Li, Bo; Cai, Wenchao; Wang, Xiaoying; Zhang, Jue; Fang, Jing

    2015-10-01

    To demonstrate the feasibility of the improved temporal resolution by using compressed sensing (CS) combined imaging sequence in dynamic contrast-enhanced MRI (DCE-MRI) of kidney, and investigate its quantitative effects on renal perfusion measurements. Ten rabbits were included in the accelerated scans with a CS-combined 3D pulse sequence. To evaluate the image quality, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between the proposed CS strategy and the conventional full sampling method. Moreover, renal perfusion was estimated by using the separable compartmental model in both CS simulation and realistic CS acquisitions. The CS method showed DCE-MRI images with improved temporal resolution and acceptable image contrast, while presenting significantly higher SNR than the fully sampled images (p<.01) at 2-, 3- and 4-X acceleration. In quantitative measurements, renal perfusion results were in good agreement with the fully sampled one (concordance correlation coefficient=0.95, 0.91, 0.88) at 2-, 3- and 4-X acceleration in CS simulation. Moreover, in realistic acquisitions, the estimated perfusion by the separable compartmental model exhibited no significant differences (p>.05) between each CS-accelerated acquisition and the full sampling method. The CS-combined 3D sequence could improve the temporal resolution for DCE-MRI in kidney while yielding diagnostically acceptable image quality, and it could provide effective measurements of renal perfusion. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. MTN-017: A Rectal Phase 2 Extended Safety and Acceptability Study of Tenofovir Reduced-Glycerin 1% Gel

    PubMed Central

    Lama, Javier R.; Richardson, Barbra A.; Carballo-Diéguez, Alex; Kunjara Na Ayudhya, Ratiya Pamela; Liu, Karen; Patterson, Karen B.; Leu, Cheng-Shiun; Galaska, Beth; Jacobson, Cindy E.; Parikh, Urvi M.; Marzinke, Mark A.; Hendrix, Craig W.; Johnson, Sherri; Piper, Jeanna M.; Grossman, Cynthia; Ho, Ken S.; Lucas, Jonathan; Pickett, Jim; Bekker, Linda-Gail; Chariyalertsak, Suwat; Chitwarakorn, Anupong; Gonzales, Pedro; Holtz, Timothy H.; Liu, Albert Y.; Mayer, Kenneth H.; Zorrilla, Carmen; Schwartz, Jill L.; Rooney, James; McGowan, Ian

    2017-01-01

    Abstract Background. Human immunodeficiency virus (HIV) disproportionately affects men who have sex with men (MSM) and transgender women (TGW). Safe and acceptable topical HIV prevention methods that target the rectum are needed. Methods. MTN-017 was a phase 2, 3-period, randomized sequence, open-label, expanded safety and acceptability crossover study comparing rectally applied reduced-glycerin (RG) 1% tenofovir (TFV) and oral emtricitabine/TFV disoproxil fumarate (FTC/TDF). In each 8-week study period participants were randomized to RG-TFV rectal gel daily, or RG-TFV rectal gel before and after receptive anal intercourse (RAI; or at least twice weekly in the event of no RAI), or daily oral FTC/TDF. Results. MSM and TGW (n = 195) were enrolled from 8 sites in the United States, Thailand, Peru, and South Africa with mean age of 31.1 years (range 18-64). There were no differences in ≥grade 2 adverse event rates between daily gel (incidence rate ratio [IRR], 1.09; P = .59) or RAI gel (IRR, 0.90; P = .51) compared to FTC/TDF. High adherence (≥80% of prescribed doses assessed by unused product return and Short Message System reports) was less likely in the daily gel regimen (odds ratio [OR], 0.35; P < .001), and participants reported less likelihood of future daily gel use for HIV protection compared to FTC/TDF (OR, 0.38; P < .001). Conclusions. Rectal application of RG TFV gel was safe in MSM and TGW. Adherence and product use likelihood were similar for the intermittent gel and daily oral FTC/TDF regimens, but lower for the daily gel regimen. Clinical Trials Registration: NCT01687218. PMID:27986684

  15. Small, high-pressure ratio compressor mechanical acceptance test, volume 2

    NASA Technical Reports Server (NTRS)

    Metty, G. R.; Shoup, W. I.

    1973-01-01

    The fabrication and mechanical testing of the high-pressure-ratio compressor are reported. Mechanical testing was performed to demonstrate overspeed capability, adequate rotor dynamics, electrical isolation of the gas bearing trunnion mounted diffuser and shroud and the effect of operating parameters (speed and pressure ratio) on clearance of the compressor test rig. The speed range covered was 20 to 120 percent of rated speed (80,000 rpm). Following these tests an acceptance test which consisted of a 5 hour run at 80,000 rpm was made with approximately design impeller to shroud clearances. For Vol. 1, see N73-26483.

  16. Different spectrophotometric methods applied for the analysis of binary mixture of flucloxacillin and amoxicillin: A comparative study.

    PubMed

    Attia, Khalid A M; Nassar, Mohammed W I; El-Zeiny, Mohamed B; Serag, Ahmed

    2016-05-15

    Three different spectrophotometric methods were applied for the quantitative analysis of flucloxacillin and amoxicillin in their binary mixture, namely, ratio subtraction, absorbance subtraction and amplitude modulation. A comparative study was done listing the advantages and the disadvantages of each method. All the methods were validated according to the ICH guidelines and the obtained accuracy, precision and repeatability were found to be within the acceptable limits. The selectivity of the proposed methods was tested using laboratory prepared mixtures and assessed by applying the standard addition technique. So, they can be used for the routine analysis of flucloxacillin and amoxicillin in their binary mixtures. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Wald Sequential Probability Ratio Test for Space Object Conjunction Assessment

    NASA Technical Reports Server (NTRS)

    Carpenter, James R.; Markley, F Landis

    2014-01-01

    This paper shows how satellite owner/operators may use sequential estimates of collision probability, along with a prior assessment of the base risk of collision, in a compound hypothesis ratio test to inform decisions concerning collision risk mitigation maneuvers. The compound hypothesis test reduces to a simple probability ratio test, which appears to be a novel result. The test satisfies tolerances related to targeted false alarm and missed detection rates. This result is independent of the method one uses to compute the probability density that one integrates to compute collision probability. A well-established test case from the literature shows that this test yields acceptable results within the constraints of a typical operational conjunction assessment decision timeline. Another example illustrates the use of the test in a practical conjunction assessment scenario based on operations of the International Space Station.

  18. Characterization of alkaline hydroxide-preserved whole poultry as a dry byproduct meal.

    PubMed

    Shafer, D J; Burgess, R P; Conrad, K A; Prochaska, J F; Carey, J B

    2001-11-01

    Studies were conducted to examine the chemical preservation of whole broiler carcasses by using aqueous alkaline hydroxide solutions. Conversion of the preserved carcasses and solutions into an acceptable poultry byproduct meal was examined. Carcasses and alkaline solutions at a 1:1 ratio were blended and freeze-dried to produce a high fat whole poultry byproduct meal. The dry meal was analyzed for nutrient composition, true metabolizable energy, and amino acid content. Viable bacteria were not recovered after inoculation of the experimental meal with Salmonella enteritidis. The meal was incorporated at 5 and 10% of chick starter diets. Chicks found the meal-containing diets acceptable. Feed consumption, water consumption, BW, and mortality were not significantly different among the dietary treatments in either of the two feeding trials. Necropsy samples revealed no pathological or histological differences attributable to consumption of the alkaline poultry byproduct and blood serum evaluation found no variation in blood chemistry. Alkaline treatment of whole broiler carcasses was an effective preservation method and acceptable as a dry poultry byproduct meal.

  19. A study of acceptors and non-acceptors of family planning methods among three tribal communities.

    PubMed

    Mutharayappa, R

    1995-03-01

    Primary data were collected from 399 currently married women of the Marati, Malekudiya, and Koraga tribes in the Dakshina Kannada district of Karnataka State in this study of the implementation of family planning programs in tribal areas. The Marati, Malekudiya, and Koraga tribes are three different endogamous tribal populations living in similar ecological conditions. Higher levels of literacy and a high rate of acceptance of family planning methods, however, have been observed among these tribes compared to the rest of the tribal population in the state. 46.4% of currently married women aged 15-49 years in the tribes were acceptors of family planning methods, having a mean 3.7 children. The majority of acceptors opted for tubectomy and vasectomy. The adoption of spacing methods is less common among tribal people. Most acceptors received their operations through government health facilities. They were motivated mainly by female health workers and received both cash and other incentives to accept family planning. The main reason for non-acceptance of family planning among non-acceptors was the desire to conceive and bear more children. The data indicate that most of the tribal households are nuclear families with household size more or less similar to that of the general population. They have a higher literacy rate than the rest of the tribal population in the state, with literacy levels between males and females and between the three tribes being quite different; the school enrollment ratio is relatively higher for both boys and girls.

  20. 12 CFR 615.5206 - Permanent capital ratio computation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Permanent capital ratio computation. 615.5206... capital ratio computation. (a) The institution's permanent capital ratio is determined on the basis of the financial statements of the institution prepared in accordance with generally accepted accounting principles...

  1. Simplex-centroid mixture formulation for optimised composting of kitchen waste.

    PubMed

    Abdullah, N; Chin, N L

    2010-11-01

    Composting is a good recycling method to fully utilise all the organic wastes present in kitchen waste due to its high nutritious matter within the waste. In this present study, the optimised mixture proportions of kitchen waste containing vegetable scraps (V), fish processing waste (F) and newspaper (N) or onion peels (O) were determined by applying the simplex-centroid mixture design method to achieve the desired initial moisture content and carbon-to-nitrogen (CN) ratio for effective composting process. The best mixture was at 48.5% V, 17.7% F and 33.7% N for blends with newspaper while for blends with onion peels, the mixture proportion was 44.0% V, 19.7% F and 36.2% O. The predicted responses from these mixture proportions fall in the acceptable limits of moisture content of 50% to 65% and CN ratio of 20-40 and were also validated experimentally. Copyright 2010 Elsevier Ltd. All rights reserved.

  2. Flow Cytometry Method Analysis of Apoptosis: No Significant Difference Between EDTA and EDTA-free Trypsin Treatment Procedure.

    PubMed

    Xu, Xiao-yan; Nie, Xiao-cui; Ma, Hai-ying; Song, Guo-qing; Zhang, Xiao-tong; Jin, Yu-nan; Yu, Yan-qiu

    2015-04-01

    Flow cytometry method (FCM) is a generally accepted tool to analyze apoptosis. Although apoptosis assay kit was applied by many companies, the manufacturers were not consistent with whether using Trypsin with EDTA to collect the adherent cells. In another words, the influence of EDTA on apoptotic ratio is not clear. In this work, we compared the proportion of apoptotic cells with EDTA or EDTA-free Trypsin treatment by FCM. We concluded that Trypsin with or without EDTA has little influence on the proportion of apoptotic cells. In addition, we found that the ratio of necrosis and apoptosis was different in cells collected by scraping. WAVE2 protein was analyzed as a typical example for movement related protein. WAVE2 expression is elevated in the EDTA Trypsin treated group, compared with EDTA-free Trypsin treatment and scrapping group. © The Author(s) 2014.

  3. Comparison of different approaches applied in Analytic Hierarchy Process - an example of information needs of patients with rare diseases.

    PubMed

    Pauer, Frédéric; Schmidt, Katharina; Babac, Ana; Damm, Kathrin; Frank, Martin; von der Schulenburg, J-Matthias Graf

    2016-09-09

    The Analytic Hierarchy Process (AHP) is increasingly used to measure patient priorities. Studies have shown that there are several different approaches to data acquisition and data aggregation. The aim of this study was to measure the information needs of patients having a rare disease and to analyze the effects of these different AHP approaches. The ranking of information needs is then used to display information categories on a web-based information portal about rare diseases according to the patient's priorities. The information needs of patients suffering from rare diseases were identified by an Internet research study and a preliminary qualitative study. Hence, we designed a three-level hierarchy containing 13 criteria. For data acquisition, the differences in outcomes were investigated using individual versus group judgements separately. Furthermore, we analyzed the different effects when using the median and arithmetic and geometric means for data aggregation. A consistency ratio ≤0.2 was determined to represent an acceptable consistency level. Forty individual and three group judgements were collected from patients suffering from a rare disease and their close relatives. The consistency ratio of 31 individual and three group judgements was acceptable and thus these judgements were included in the study. To a large extent, the local ranks for individual and group judgements were similar. Interestingly, group judgements were in a significantly smaller range than individual judgements. According to our data, the ranks of the criteria differed slightly according to the data aggregation method used. It is important to explain and justify the choice of an appropriate method for data acquisition because response behaviors differ according to the method. We conclude that researchers should select a suitable method based on the thematic perspective or investigated topics in the study. Because the arithmetic mean is very vulnerable to outliers, the geometric mean and the median seem to be acceptable alternatives for data aggregation. Overall, using the AHP to identify patient priorities and enhance the user-friendliness of information websites offers an important contribution to medical informatics.

  4. Cost-effectiveness acceptability curves revisited.

    PubMed

    Al, Maiwenn J

    2013-02-01

    Since the introduction of the cost-effectiveness acceptability curve (CEAC) in 1994, its use as a method to describe uncertainty around incremental cost-effectiveness ratios (ICERs) has steadily increased. In this paper, first the construction and interpretation of the CEAC is explained, both in the context of modelling studies and in the context of cost-effectiveness (CE) studies alongside clinical trials. Additionally, this paper reviews the advantages and limitations of the CEAC. Many of the perceived limitations can be attributed to the practice of interpreting the CEAC as a decision rule while it was not developed as such. It is argued that the CEAC is still a useful tool in describing and quantifying uncertainty around the ICER, especially in combination with other tools such as plots on the CE plane and value-of-information analysis.

  5. Fitness level and body composition indices: cross-sectional study among Malaysian adolescent

    PubMed Central

    2014-01-01

    Background The importance of fitness level on the well-being of children and adolescent has long been recognised. The aim of this study was to investigate the fitness level of school-going Malaysian adolescent, and its association with body composition indices. Methods 1071 healthy secondary school students participated in the fitness assessment for the Malaysian Health and Adolescents Longitudinal Research Team (MyHEART) study. Body composition indices such as body mass index for age, waist circumference and waist height ratio were measured. Fitness level was assessed with Modified Harvard Step Test. Physical Fitness Score was calculated using total time of step test exercise and resting heart rates. Fitness levels were divided into 3 categories - unacceptable, marginally acceptable, and acceptable. Partial correlation analysis was used to determine the association between fitness score and body composition, by controlling age, gender, locality, ethnicity, smoking status and sexual maturation. Multiple regression analysis was conducted to determine which body composition was the strongest predictor for fitness. Results 43.3% of the participants were categorised into the unacceptable fitness group, 47.1% were considered marginally acceptable, and 9.6% were acceptable. There was a significant moderate inverse association (p < 0.001) between body composition with fitness score (r = -0.360, -0.413 and -0.403 for body mass index for age, waist circumference and waist height ratio, respectively). Waist circumference was the strongest and significant predictor for fitness (ß = -0.318, p = 0.002). Conclusion Only 9.6% of the students were fit. There was also an inverse association between body composition and fitness score among apparently healthy adolescents, with waist circumference indicated as the strongest predictor. The low fitness level among the Malaysian adolescent should necessitate the value of healthy lifestyle starting at a young age. PMID:25436933

  6. Differences between willingness to pay and willingness to accept for visits by a family physician: A contingent valuation study

    PubMed Central

    2010-01-01

    Background The economic value attributed by users of health services in public health systems can be useful in planning and evaluation. This value can differ from the perspectives of Willingness to Pay (WTP) and Willingness to Accept [Compensation] (WTA). Our objective was to study the perceptions of the patient about the service provided by the family physician by means of the WTA/WTP ratio. Methods An economic evaluation study by the Contingent Valuation Method was designed. Interviews were conducted with 451 subjects at six health centres (four urban and two rural) in areas with different socioeconomic characteristics. A payment card was used to measure the WTP and WTA. Other characteristics of the subject or service that could influence these responses were collected. An explicative model was constructed to study the WTA/WTP relationship. Results Four hundred and four subjects (89.6%) expressed a WTP and WTA different from zero. The WTA/WTP quotient showed a median of 1.55 (interquartile range 1-3.08) and a mean of 3.30 (IC 95%: 2.84-3.75). The WTA/WTP ratio increases with age and in low-income areas. It decreases in professional groups with more specialized activities, with growing family income, and in the chronically ill. Other characteristics related to the perception of state of health, accessibility to the service, satisfaction, or perception of risk were not explicative. Conclusions Subjects who were older and had a less favourable socioeconomic situation expressed a higher WTA/WTP ratio when valuing the visit to the family physician. These characteristics could identify a profile of "aversion to loss" with respect to this service. PMID:20459714

  7. Small, high pressure ratio compressor: Aerodynamic and mechanical design

    NASA Technical Reports Server (NTRS)

    Bryce, C. A.; Erwin, J. R.; Perrone, G. L.; Nelson, E. L.; Tu, R. K.; Bosco, A.

    1973-01-01

    The Small, High-Pressure-Ratio Compressor Program was directed toward the analysis, design, and fabrication of a centrifugal compressor providing a 6:1 pressure ratio and an airflow rate of 2.0 pounds per second. The program consists of preliminary design, detailed areodynamic design, mechanical design, and mechanical acceptance tests. The preliminary design evaluate radial- and backward-curved blades, tandem bladed impellers, impeller-and diffuser-passage boundary-layer control, and vane, pipe, and multiple-stage diffusers. Based on this evaluation, a configuration was selected for detailed aerodynamic and mechanical design. Mechanical acceptance test was performed to demonstrate that mechanical design objectives of the research package were met.

  8. Depression screening among older adults attending low-vision rehabilitation and eye-care services: Characteristics of those who screen positive and client acceptability of screening.

    PubMed

    Holloway, Edith E; Sturrock, Bonnie A; Lamoureux, Ecosse L; Keeffe, Jill E; Rees, Gwyneth

    2015-12-01

    To investigate characteristics associated with screening positive for depressive symptoms among older adults accessing low-vision rehabilitation and eye-care services and to determine client acceptability of depression screening using the Patient Health Questionnaire-2 (PHQ-2) in these settings. One-hundred and twenty-four older adults (mean = 77.02 years, SD = 9.12) attending low-vision rehabilitation and eye-care services across Australia were screened for depression and invited to complete a telephone-administered questionnaire to determine characteristics associated with depressive symptoms and client acceptability of screening in these settings. Thirty-seven per cent (n = 46/124) of participants screened positive for depressive symptoms, and the majority considered the new depression screening method to be a 'good idea' in vision services (85%). Severe vision loss (<6/60 in the better eye) was associated with an increased odds of screening positive for depressive symptoms (odds ratio 2.37; 95% confidence interval 1.08-6.70) even after adjusting for potential confounders. Participants who screened positive had a preference for 'talking' therapy or a combination of medication and 'talking therapy' delivered within their own home (73%) or via telephone (67%). The PHQ-2 appears to be an acceptable method for depression screening in eye-care settings among older adults. Targeted interventions that incorporate home-based or telephone delivered therapy sessions may improve outcomes for depression in this group. © 2014 ACOTA.

  9. Declining sex ratio: role of society, technology and government regulation in Faridabad district, Haryana.

    PubMed

    Bardia, A; Paul, E; Kapoor, S K; Anand, K

    2004-01-01

    A declining sex ratio at birth has been documented during censuses in India. The decline is especially more in the northern states of Haryana and Punjab. We attempted to assess the role of society (preference for a male child, awareness and acceptability of the practice of sex determination), technology (availability and affordability) and government regulation in the adverse ratio for girls in the Ballabgarh block of Haryana in northern India. The population (about 80 000) in the Ballabgarh block has been under constant demographic surveillance for the past 30 years and the data are stored electronically. This was used to determine the sex ratio at birth in the area since 1990. The data on availability of ultrasound machines was collected from the district authorities, as registration of these machines was made mandatory under the Prenatal Diagnostic Techniques Act, 1994. We interviewed 160 mothers and grandmothers to determine the awareness and acceptability of sex determination methods and practices. The demographic data for the past 10 years showed a declining sex ratio-from 881 in 1990-91 to 833 in 2000-01. The data support the view that in the initial part of this period, ultrasound was used for sex determination of all-order births but subsequently was used more in higher-order births. Our interviews with the mothers and grandmothers of the area showed that the practice of sex determination is prevalent and the attitude of the society is ambivalent. The increased availability of ultrasound machines in the area in the past 10 years corresponded to the decline in sex ratio. When the government made the practice illegal, the sex ratio improved only to fall again as the law was not implemented. Later years saw a more stringent implementation of the law and the sex ratio improved again. There is a 'demand' for sex determination technology and, therefore, this would continue to be 'supplied'. At most the 'supply' can be regulated. Social engineering efforts need to be targeted at reducing the demand if the sex ratio is to be improved.

  10. Cost-Effectiveness Analysis: a proposal of new reporting standards in statistical analysis

    PubMed Central

    Bang, Heejung; Zhao, Hongwei

    2014-01-01

    Cost-effectiveness analysis (CEA) is a method for evaluating the outcomes and costs of competing strategies designed to improve health, and has been applied to a variety of different scientific fields. Yet, there are inherent complexities in cost estimation and CEA from statistical perspectives (e.g., skewness, bi-dimensionality, and censoring). The incremental cost-effectiveness ratio that represents the additional cost per one unit of outcome gained by a new strategy has served as the most widely accepted methodology in the CEA. In this article, we call for expanded perspectives and reporting standards reflecting a more comprehensive analysis that can elucidate different aspects of available data. Specifically, we propose that mean and median-based incremental cost-effectiveness ratios and average cost-effectiveness ratios be reported together, along with relevant summary and inferential statistics as complementary measures for informed decision making. PMID:24605979

  11. Evaluation of the suitability of neural network method for prediction of uranium activity ratio in environmental alpha spectra.

    PubMed

    Einian, Mohammad Reza; Aghamiri, Seyed Mahmood Reza; Ghaderi, Reza

    2015-11-01

    Applying Artificial Neural Network to an alpha spectrometry system is a good idea to discriminate the composition of environmental and non-environmental materials by the estimation of the (234)U/(238)U activity ratio. Because it eliminates limitations of classical approaches by the extraction the desired information from the average of a partial uranium raw spectrum. The network was trained by an alpha spectrum library which was developed in this work. The results indicated that there was a small difference between the target values and the predictions. These results were acceptable, because the thickness of samples and the inferring elements were different in the real library. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Sphericity determination using resonant ultrasound spectroscopy

    DOEpatents

    Dixon, Raymond D.; Migliori, Albert; Visscher, William M.

    1994-01-01

    A method is provided for grading production quantities of spherical objects, such as roller balls for bearings. A resonant ultrasound spectrum (RUS) is generated for each spherical object and a set of degenerate sphere-resonance frequencies is identified. From the degenerate sphere-resonance frequencies and known relationships between degenerate sphere-resonance frequencies and Poisson's ratio, a Poisson's ratio can be determined, along with a "best" spherical diameter, to form spherical parameters for the sphere. From the RUS, fine-structure resonant frequency spectra are identified for each degenerate sphere-resonance frequency previously selected. From each fine-structure spectrum and associated sphere parameter values an asphericity value is determined. The asphericity value can then be compared with predetermined values to provide a measure for accepting or rejecting the sphere.

  13. Sphericity determination using resonant ultrasound spectroscopy

    DOEpatents

    Dixon, R.D.; Migliori, A.; Visscher, W.M.

    1994-10-18

    A method is provided for grading production quantities of spherical objects, such as roller balls for bearings. A resonant ultrasound spectrum (RUS) is generated for each spherical object and a set of degenerate sphere-resonance frequencies is identified. From the degenerate sphere-resonance frequencies and known relationships between degenerate sphere-resonance frequencies and Poisson's ratio, a Poisson's ratio can be determined, along with a 'best' spherical diameter, to form spherical parameters for the sphere. From the RUS, fine-structure resonant frequency spectra are identified for each degenerate sphere-resonance frequency previously selected. From each fine-structure spectrum and associated sphere parameter values an asphericity value is determined. The asphericity value can then be compared with predetermined values to provide a measure for accepting or rejecting the sphere. 14 figs.

  14. Seasonal Influenza Vaccine Acceptance among Pregnant Women in Zhejiang Province, China: Evidence Based on Health Belief Model.

    PubMed

    Hu, Yu; Wang, Ying; Liang, Hui; Chen, Yaping

    2017-12-11

    Background: Reasons for acceptance of seasonal influenza vaccine (SIV) vaccination among pregnant women in China are poorly understood. We assessed the intention to accept SIV among pregnant women in Zhejiang province, by using a self-administrated structured questionnaire developed on the basis of health belief model (HBM). Methods: From 1 January to 31 March 2014, pregnant women with ≥12 gestational weeks who attended antenatal clinics (ANCs) at public hospitals in 6 out of 90 districts were surveyed using a self-administered questionnaire that covered knowledge, attitudes, and beliefs related to SIV vaccination and influenza infection. We examined the associations between the acceptance of SIV vaccination and the demographic factors and HBM constructs using the logistic regression model, calculating the adjusted odds ratio (AOR). Results: Of the 1252 participants, 76.28% were willing to receive the SIV vaccination during their current pregnancy. High levels of perceived susceptibility of influenza (AOR = 1.75 (95%CI: 1.36-2.08)), high levels of perceived severity of influenza (AOR = 1.62 (95%CI: 1.25-1.95)), high level of perceived benefits of vaccination (AOR = 1.97 (95%CI: 1.76-2.21)), and high levels of cues to action were positively associated with the acceptance of SIV vaccination among pregnant women (AOR = 2.03 (95%CI: 1.70-2.69)), while high level of perceived barriers of vaccination was a negative determinant (AOR = 0.76 (95%CI: 0.62-0.94)). Conclusions: Poor knowledge and negative attitude towards SIV were associated with the poor acceptance of SIV. Health providers' recommendations were important to pregnant women's acceptance of SIV. Health education and direct communication strategies on SIV vaccination and influenza infection are necessary to improve the acceptance of SIV vaccination among pregnant women.

  15. Willingness to Accept HIV Pre-Exposure Prophylaxis among Chinese Men Who Have Sex with Men

    PubMed Central

    Li, Shuming; Li, Dongliang; Zhang, Lifen; Fan, Wensheng; Yang, Xueying; Yu, Mingrun; Xiao, Dong; Yan, Li; Zhang, Zheng; Shi, Wei; Luo, Fengji; Ruan, Yuhua; Jin, Qi

    2012-01-01

    Objective We investigated the awareness and acceptability of pre-exposure prophylaxis (PrEP) among men who have sex with men (MSM) and potential predicting factors. Methods This study was conducted among MSM in Beijing, China. Study participants, randomly selected from an MSM cohort, completed a structured questionnaire, and provided their blood samples to test for HIV infection and syphilis. Univariate logistic regression analyses were performed to evaluate the factors associated with willingness to accept (WTA) PrEP. Factors independently associated with willingness to accept were identified by entering variables into stepwise logistic regression analysis. Results A total of 152 MSM completed the survey; 11.2% had ever heard of PrEP and 67.8% were willing to accept it. Univariate analysis showed that age, years of education, consistent condom use in the past 6 months, heterosexual behavior in the past 6 months, having ever heard of PrEP and the side effects of antiretroviral drugs, and worry about antiretroviral drugs cost were significantly associated with willingness to accept PrEP. In the multivariate logistic regression model, only consistent condom use in the past 6 months (odds ratio [OR]: 0.31; 95% confidence interval [CI]: 0.13–0.70) and having ever heard of the side effects of antiretroviral drugs (OR: 0.30; 95% CI: 0.14–0.67) were independently associated with willingness to accept PrEP. Conclusions The awareness of PrEP in the MSM population was low. Sexual behavioral characteristics and knowledge about ART drugs may have effects on willingness to accept PrEP. Comprehensive prevention strategies should be recommended in the MSM community. PMID:22479320

  16. Selection Input Output by Restriction Using DEA Models Based on a Fuzzy Delphi Approach and Expert Information

    NASA Astrophysics Data System (ADS)

    Arsad, Roslah; Nasir Abdullah, Mohammad; Alias, Suriana; Isa, Zaidi

    2017-09-01

    Stock evaluation has always been an interesting problem for investors. In this paper, a comparison regarding the efficiency stocks of listed companies in Bursa Malaysia were made through the application of estimation method of Data Envelopment Analysis (DEA). One of the interesting research subjects in DEA is the selection of appropriate input and output parameter. In this study, DEA was used to measure efficiency of stocks of listed companies in Bursa Malaysia in terms of the financial ratio to evaluate performance of stocks. Based on previous studies and Fuzzy Delphi Method (FDM), the most important financial ratio was selected. The results indicated that return on equity, return on assets, net profit margin, operating profit margin, earnings per share, price to earnings and debt to equity were the most important ratios. Using expert information, all the parameter were clarified as inputs and outputs. The main objectives were to identify most critical financial ratio, clarify them based on expert information and compute the relative efficiency scores of stocks as well as rank them in the construction industry and material completely. The methods of analysis using Alirezaee and Afsharian’s model were employed in this study, where the originality of Charnes, Cooper and Rhodes (CCR) with the assumption of Constant Return to Scale (CSR) still holds. This method of ranking relative efficiency of decision making units (DMUs) was value-added by the Balance Index. The interested data was made for year 2015 and the population of the research includes accepted companies in stock markets in the construction industry and material (63 companies). According to the ranking, the proposed model can rank completely for 63 companies using selected financial ratio.

  17. Half-life of Th232 and the branching ratio of Bi212

    USGS Publications Warehouse

    Senftle, F.E.; Farley, T.A.; Lazar, N.

    1956-01-01

    The half-life of Th232 has been calculated by determining an absolute gamma-disintegration rate for Tl208 in equilibrium with Th232 for three old thorium nitrate salts and one natural thorite sample. The branching ratio, ??(??+??), for Bi212, a necessary parameter in the calculation, was also measured. The half-life of Th232 was found to be 1.42??1010 years within an estimated error of 5%, which is essentially in agreement with the presently accepted value. The branching ratio, ??(??+??), of Bi212 was found to be 0.362??0.006, about 7.4% higher than the currently accepted value. ?? 1956 The American Physical Society.

  18. Comparison of LCModel and SAGE in Analysis of Brain Metabolite Concentrations-A study of Patients with Mild Cognitive Impairment.

    PubMed

    Shih, Chiu-Ming; Lai, Jui-Jen; Chang, Chin-Ching; Chen, Cheng-Sheng; Yeh, Yi-Chun; Jaw, Twei-Shiun; Hsu, Jui-Sheng; Li, Chun-Wei

    2017-03-15

    The purpose of this study was to compare brain metabolite concentration ratios determined by LCModel and Spectroscopy Analysis by General Electric (SAGE) quantitative methods to elucidate the advantages and disadvantages of each method. A total of 10 healthy volunteers and 10 patients with mild cognitive impairment (MCI) were recruited in this study. A point-resolved spectroscopy (PRESS) sequence was used to obtain the brain magnetic resonance spectroscopy (MRS) spectra of the volunteers and patients, as well as the General Electric (GE) MRS-HD-sphere phantom. The brain metabolite concentration ratios were estimated based on the peak area obtained from both LCModel and SAGE software. Three brain regions were sampled for each volunteer or patient, and 20 replicates were acquired at different times for the phantom analysis. The metabolite ratios of the GE phantom were estimated to be myo-inositol (mI)/creatine (Cr): 0.70 ± 0.01, choline (Cho)/Cr: 0.37 ± 0.00, N-acetylaspartate (NAA)/Cr: 1.26 ± 0.02, and NAA/mI: 1.81 ± 0.04 by LCModel, and mI/Cr: 0.88 ± 0.15, Cho/Cr: 0.35 ± 0.01, NAA/Cr: 1.33 ± 0.03, and NAA/mI: 1.55 ± 0.26 by SAGE. In the healthy volunteers and MCI patients, the ratios of mI/Cr and Cho/Cr estimated by LCModel were higher than those estimated by SAGE. In contrast, the ratio of NAA/Cr estimated by LCModel was lower than that estimated by SAGE. Both methods were acceptable in estimating brain metabolite concentration ratios. However, LCModel was marginally more accurate than SAGE because of its full automation, basis set, and user independency.

  19. Comparing multiple competing interventions in the absence of randomized trials using clinical risk-benefit analysis

    PubMed Central

    2012-01-01

    Background To demonstrate the use of risk-benefit analysis for comparing multiple competing interventions in the absence of randomized trials, we applied this approach to the evaluation of five anticoagulants to prevent thrombosis in patients undergoing orthopedic surgery. Methods Using a cost-effectiveness approach from a clinical perspective (i.e. risk benefit analysis) we compared thromboprophylaxis with warfarin, low molecular weight heparin, unfractionated heparin, fondaparinux or ximelagatran in patients undergoing major orthopedic surgery, with sub-analyses according to surgery type. Proportions and variances of events defining risk (major bleeding) and benefit (thrombosis averted) were obtained through a meta-analysis and used to define beta distributions. Monte Carlo simulations were conducted and used to calculate incremental risks, benefits, and risk-benefit ratios. Finally, net clinical benefit was calculated for all replications across a range of risk-benefit acceptability thresholds, with a reference range obtained by estimating the case fatality rate - ratio of thrombosis to bleeding. Results The analysis showed that compared to placebo ximelagatran was superior to other options but final results were influenced by type of surgery, since ximelagatran was superior in total knee replacement but not in total hip replacement. Conclusions Using simulation and economic techniques we demonstrate a method that allows comparing multiple competing interventions in the absence of randomized trials with multiple arms by determining the option with the best risk-benefit profile. It can be helpful in clinical decision making since it incorporates risk, benefit, and personal risk acceptance. PMID:22233221

  20. Method for thermal and structural evaluation of shallow intense-beam deposition in matter

    NASA Astrophysics Data System (ADS)

    Pilan Zanoni, André

    2018-05-01

    The projected range of high-intensity proton and heavy-ion beams at energies below a few tens of MeV/A in matter can be as short as a few micrometers. For the evaluation of temperature and stresses from a shallow beam energy deposition in matter conventional numerical 3D models require minuscule element sizes for acceptable element aspect ratio as well as extremely short time steps for numerical convergence. In order to simulate energy deposition using a manageable number of elements this article presents a method using layered elements. This method is applied to beam stoppers and accidental intense-beam impact onto UHV sector valves. In those cases the thermal results from the new method are congruent to those from conventional solid-element and adiabatic models.

  1. [Bayesian approach for the cost-effectiveness evaluation of healthcare technologies].

    PubMed

    Berchialla, Paola; Gregori, Dario; Brunello, Franco; Veltri, Andrea; Petrinco, Michele; Pagano, Eva

    2009-01-01

    The development of Bayesian statistical methods for the assessment of the cost-effectiveness of health care technologies is reviewed. Although many studies adopt a frequentist approach, several authors have advocated the use of Bayesian methods in health economics. Emphasis has been placed on the advantages of the Bayesian approach, which include: (i) the ability to make more intuitive and meaningful inferences; (ii) the ability to tackle complex problems, such as allowing for the inclusion of patients who generate no cost, thanks to the availability of powerful computational algorithms; (iii) the importance of a full use of quantitative and structural prior information to produce realistic inferences. Much literature comparing the cost-effectiveness of two treatments is based on the incremental cost-effectiveness ratio. However, new methods are arising with the purpose of decision making. These methods are based on a net benefits approach. In the present context, the cost-effectiveness acceptability curves have been pointed out to be intrinsically Bayesian in their formulation. They plot the probability of a positive net benefit against the threshold cost of a unit increase in efficacy.A case study is presented in order to illustrate the Bayesian statistics in the cost-effectiveness analysis. Emphasis is placed on the cost-effectiveness acceptability curves. Advantages and disadvantages of the method described in this paper have been compared to frequentist methods and discussed.

  2. Five different spectrophotometric methods for determination of Amprolium hydrochloride and Ethopabate binary mixture

    NASA Astrophysics Data System (ADS)

    Hussein, Lobna A.; Magdy, N.; Abbas, Mahmoud M.

    2015-03-01

    Five simple, specific, accurate and precise UV-spectrophotometric methods are adopted for the simultaneous determination of Amprolium hydrochloride (AMP) and Ethopabate (ETH), a binary mixture with overlapping spectra, without preliminary separation. The first method is first derivative of the ratio spectra (1DD) for determination of AMP and ETH at 234.7 nm and 306.8 nm respectively with mean percentage recoveries 99.76 ± 0.907 and 100.29 ± 0.842 respectively. The second method is the mean centering of the ratio spectra for determination of AMP and ETH at 238.8 nm and 313 nm respectively with mean percentage recoveries 100.26 ± 1.018 and 99.94 ± 1.286 respectively. The third method is based on dual wavelength selection for determination of AMP and ETH at 235.3 nm & 308 nm and 244 nm & 268.4 nm respectively with mean percentage recoveries 99.30 ± 1.097 and 100.03 ± 1.065 respectively. The fourth method is ratio difference method for determination of AMP and ETH at 239 nm & 310 nm and 239 nm & 313 nm respectively with mean percentage recoveries 99.27 ± 0.892 and 100.40 ± 1.814 respectively. The fifth one is area under the curve (AUC) method where the areas between 235.6-243 nm and 268.3-275 nm are selected for determination of AMP and ETH with mean percentage recoveries 100.35 ± 1.031 and 100.39 ± 0.956 respectively. These methods are tested by analyzing synthetic mixtures of the two drugs and they are applied to their pharmaceutical veterinary preparation. Methods are validated according to the ICH guidelines and accuracy, precision and repeatability are found to be within the acceptable limit.

  3. Acceptable range of speech level in noisy sound fields for young adults and elderly persons.

    PubMed

    Sato, Hayato; Morimoto, Masayuki; Ota, Ryo

    2011-09-01

    The acceptable range of speech level as a function of background noise level was investigated on the basis of word intelligibility scores and listening difficulty ratings. In the present study, the acceptable range is defined as the range that maximizes word intelligibility scores and simultaneously does not cause a significant increase in listening difficulty ratings from the minimum ratings. Listening tests with young adult and elderly listeners demonstrated the following. (1) The acceptable range of speech level for elderly listeners overlapped that for young listeners. (2) The lower limit of the acceptable speech level for both young and elderly listeners was 65 dB (A-weighted) for noise levels of 40 and 45 dB (A-weighted), a level with a speech-to-noise ratio of +15 dB for noise levels of 50 and 55 dB, and a level with a speech-to-noise ratio of +10 dB for noise levels from 60 to 70 dB. (3) The upper limit of the acceptable speech level for both young and elderly listeners was 80 dB for noise levels from 40 to 55 dB and 85 dB or above for noise levels from 55 to 70 dB. © 2011 Acoustical Society of America

  4. Method of experimental and calculation determination of dissipative properties of carbon

    NASA Astrophysics Data System (ADS)

    Kazakova, Olga I.; Smolin, Igor Yu.; Bezmozgiy, Iosif M.

    2017-12-01

    This paper describes the process of definition of relations between the damping ratio and strain/state levels in a material. For these purposes, the experimental-calculation approach was applied. The experimental research was performed on plane composite specimens. The tests were accompanied by finite element modeling using the ANSYS software. Optimization was used as a tool for FEM property setting and for finding the above-mentioned relations. A difference between the calculation and experimental results was accepted as objective functions of this optimization. The optimization cycle was implemented using the pSeven DATADVANCE software platform. The developed approach makes it possible to determine the relations between the damping ratio and strain/state levels in the material, which can be used for computer modeling of the structure response under dynamic loading.

  5. Ionic liquid-based air-assisted liquid-liquid microextraction followed by high performance liquid chromatography for the determination of five fungicides in juice samples.

    PubMed

    You, Xiangwei; Chen, Xiaochu; Liu, Fengmao; Hou, Fan; Li, Yiqiang

    2018-01-15

    A novel and simple ionic liquid-based air-assisted liquid-liquid microextraction technique combined with high performance liquid chromatography was developed to analyze five fungicides in juice samples. In this method, ionic liquid was used instead of a volatile organic solvent as the extraction solvent. The emulsion was formed by pulling in and pushing out the mixture of aqueous sample solution and extraction solvent repeatedly using a 10mL glass syringe. No organic dispersive solvent was required. Under the optimized conditions, the limits of detection (LODs) were 0.4-1.8μgL -1 at a signal-to-noise ratio of 3. The limits of quantification (LOQs) set as the lowest spiking levels with acceptable recovery in juices were 10μgL -1 , except for fludioxonil whose LOQ was 20μgL -1 . The proposed method was applied to determine the target fungicides in juice samples, and acceptable recoveries ranging from 74.9% to 115.4% were achieved. Copyright © 2017. Published by Elsevier Ltd.

  6. Impact of tube current modulation on lesion conspicuity index in hi-resolution chest computed tomography

    NASA Astrophysics Data System (ADS)

    Szczepura, Katy; Tomkinson, David; Manning, David

    2017-03-01

    Tube current modulation is a method employed in the use of CT in an attempt to optimize radiation dose to the patient. The acceptable noise (noise index) can be varied, based on the level of optimization required; higher accepted noise reduces the patient dose. Recent research [1] suggests that measuring the conspicuity index (C.I.) of focal lesions within an image is more reflective of a clinical reader's ability to perceive focal lesions than traditional physical measures such as contrast to noise (CNR) and signal to noise ratio (SNR). Software has been developed and validated to calculate the C.I. in DICOM images. The aim of this work is assess the impact of tube current modulation on conspicuity index and CTDIvol, to indicate the benefits and limitations of tube current modulation on lesion detectability. Method An anthropomorphic chest phantom was used "Lungman" with inserted lesions of varying size and HU (see table below) a range of Hounsfield units and sizes were used to represent the variation in lesion Hounsfield units found. This meant some lesions had negative Hounsfield unit values.

  7. Numerical investigation of the variable nozzle effect on the mixed flow turbine performance characteristics

    NASA Astrophysics Data System (ADS)

    Meziri, B.; Hamel, M.; Hireche, O.; Hamidou, K.

    2016-09-01

    There are various matching ways between turbocharger and engine, the variable nozzle turbine is the most significant method. The turbine design must be economic with high efficiency and large capacity over a wide range of operational conditions. These design intents are used in order to decrease thermal load and improve thermal efficiency of the engine. This paper presents an original design method of a variable nozzle vane for mixed flow turbines developed from previous experimental and numerical studies. The new device is evaluated with a numerical simulation over a wide range of rotational speeds, pressure ratios, and different vane angles. The compressible turbulent steady flow is solved using the ANSYS CFX software. The numerical results agree well with experimental data in the nozzleless configuration. In the variable nozzle case, the results show that the turbine performance characteristics are well accepted in different open positions and improved significantly in low speed regime and at low pressure ratio.

  8. Parental Acceptability of Contraceptive Methods Offered to their Teen During a Confidential Health Care Visit

    PubMed Central

    Hartman, Lauren B; Shafer, Mary-Ann; Pollack, Lance M; Wibbelsman, Charles; Chang, Fay; Tebb, Kathleen P

    2013-01-01

    Purpose To examine parental acceptability of contraceptive methods offered confidentially to their adolescent daughter. Methods A random sample of 261 parents/guardians with a daughter between 12–17 completed a telephone survey examining the relationship between parental acceptability of seven contraceptive methods with adolescents’ likelihood to have sex, parenting beliefs, parents’ sexual health as teens, sexually transmitted infection (STI) knowledge, and demographic factors. Results Acceptability was highest for oral contraceptive pills (59%), and lowest for intrauterine device (IUD) (18%). Parental acceptance of teens’ autonomy was significantly associated with increased acceptability of all methods. Parental knowledge of STIs was poor and 51% found it acceptable for clinicians to provide their sexually active teen with condoms. Conclusion Conclusions: Parents were more accepting of OCPs and condoms, compared to IUDs and implants. Parental recognition of their teen’s autonomy was associated with greater parental acceptability of clinicians providing their adolescent with contraceptives (regardless of the specific type of method being offered). PMID:23332493

  9. 30 CFR 36.44 - Maximum allowable fuel : air ratio.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... delivered to MSHA with the fuel-injection system adjusted by the applicant and tests of the exhaust-gas... adjustment of the fuel-injection system shall be accepted. The maximum fuel : air ratio determined from the... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Maximum allowable fuel : air ratio. 36.44...

  10. 30 CFR 36.44 - Maximum allowable fuel : air ratio.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... delivered to MSHA with the fuel-injection system adjusted by the applicant and tests of the exhaust-gas... adjustment of the fuel-injection system shall be accepted. The maximum fuel : air ratio determined from the... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Maximum allowable fuel : air ratio. 36.44...

  11. 30 CFR 36.44 - Maximum allowable fuel : air ratio.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... delivered to MSHA with the fuel-injection system adjusted by the applicant and tests of the exhaust-gas... adjustment of the fuel-injection system shall be accepted. The maximum fuel : air ratio determined from the... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Maximum allowable fuel : air ratio. 36.44...

  12. 30 CFR 36.44 - Maximum allowable fuel:air ratio.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... delivered to MSHA with the fuel-injection system adjusted by the applicant and tests of the exhaust-gas... adjustment of the fuel-injection system shall be accepted. The maximum fuel:air ratio determined from the... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Maximum allowable fuel:air ratio. 36.44 Section...

  13. 30 CFR 36.44 - Maximum allowable fuel : air ratio.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... delivered to MSHA with the fuel-injection system adjusted by the applicant and tests of the exhaust-gas... adjustment of the fuel-injection system shall be accepted. The maximum fuel : air ratio determined from the... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Maximum allowable fuel : air ratio. 36.44...

  14. Development of ultrasound/endoscopy PACS (picture archiving and communication system) and investigation of compression method for cine images

    NASA Astrophysics Data System (ADS)

    Osada, Masakazu; Tsukui, Hideki

    2002-09-01

    ABSTRACT Picture Archiving and Communication System (PACS) is a system which connects imaging modalities, image archives, and image workstations to reduce film handling cost and improve hospital workflow. Handling diagnostic ultrasound and endoscopy images is challenging, because it produces large amount of data such as motion (cine) images of 30 frames per second, 640 x 480 in resolution, with 24-bit color. Also, it requires enough image quality for clinical review. We have developed PACS which is able to manage ultrasound and endoscopy cine images with above resolution and frame rate, and investigate suitable compression method and compression rate for clinical image review. Results show that clinicians require capability for frame-by-frame forward and backward review of cine images because they carefully look through motion images to find certain color patterns which may appear in one frame. In order to satisfy this quality, we have chosen motion JPEG, installed and confirmed that we could capture this specific pattern. As for acceptable image compression rate, we have performed subjective evaluation. No subjects could tell the difference between original non-compressed images and 1:10 lossy compressed JPEG images. One subject could tell the difference between original and 1:20 lossy compressed JPEG images although it is acceptable. Thus, ratios of 1:10 to 1:20 are acceptable to reduce data amount and cost while maintaining quality for clinical review.

  15. Outer planet Pioneer imaging communications system study. [data compression

    NASA Technical Reports Server (NTRS)

    1974-01-01

    The effects of different types of imaging data compression on the elements of the Pioneer end-to-end data system were studied for three imaging transmission methods. These were: no data compression, moderate data compression, and the advanced imaging communications system. It is concluded that: (1) the value of data compression is inversely related to the downlink telemetry bit rate; (2) the rolling characteristics of the spacecraft limit the selection of data compression ratios; and (3) data compression might be used to perform acceptable outer planet mission at reduced downlink telemetry bit rates.

  16. Recruitment of patients into head and neck clinical trials: acceptability of studies to patients from perspective of the research team.

    PubMed

    Ho, M W; Pick, A S; Sutton, D N; Dyker, K; Cardale, K; Gilbert, K; Johnson, J; Quantrill, J; McCaul, J A

    2018-05-01

    We reviewed longitudinal recruitment data to assess recruitment into head and neck cancer trials, and to identify factors that could influence this and affect their acceptability to patients. We retrieved data from the prospective computerised database (2009-2016) to measure acceptability to patients using the recruitment:screening ratio, and compared observational with interventional studies, single specialty (or site) with multispecialty (or site) studies, and "step-up" randomisation with "non-inferiority" randomisation designs. A total of 1283 patients were screened and 583 recruited. The recruitment:screening ratio for all National Institute for Health Research (NIHR) portfolio studies combined was 0.47 (486/1133). Studies that involved treatment by several specialties or at several sites had a significantly adverse impact on acceptability (p=0.01). Recruitment into non-inferiority randomised controlled studies was lower than that into step-up randomised studies (p=0.06). The complexity of a study's design did not compromise recruitment. Treatment across several specialties or several sites and perceived non-inferiority designs, reduced the acceptability of some trials. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  17. Two-stage solar concentrators based on parabolic troughs: asymmetric versus symmetric designs.

    PubMed

    Schmitz, Max; Cooper, Thomas; Ambrosetti, Gianluca; Steinfeld, Aldo

    2015-11-20

    While nonimaging concentrators can approach the thermodynamic limit of concentration, they generally suffer from poor compactness when designed for small acceptance angles, e.g., to capture direct solar irradiation. Symmetric two-stage systems utilizing an image-forming primary parabolic concentrator in tandem with a nonimaging secondary concentrator partially overcome this compactness problem, but their achievable concentration ratio is ultimately limited by the central obstruction caused by the secondary. Significant improvements can be realized by two-stage systems having asymmetric cross-sections, particularly for 2D line-focus trough designs. We therefore present a detailed analysis of two-stage line-focus asymmetric concentrators for flat receiver geometries and compare them to their symmetric counterparts. Exemplary designs are examined in terms of the key optical performance metrics, namely, geometric concentration ratio, acceptance angle, concentration-acceptance product, aspect ratio, active area fraction, and average number of reflections. Notably, we show that asymmetric designs can achieve significantly higher overall concentrations and are always more compact than symmetric systems designed for the same concentration ratio. Using this analysis as a basis, we develop novel asymmetric designs, including two-wing and nested configurations, which surpass the optical performance of two-mirror aplanats and are comparable with the best reported 2D simultaneous multiple surface designs for both hollow and dielectric-filled secondaries.

  18. Low tube voltage computed tomography urography using low-concentration contrast media: Comparison of image quality in conventional computed tomography urography.

    PubMed

    Hwang, Inpyeong; Cho, Jeong Yeon; Kim, Sang Youn; Oh, Seung-June; Ku, Ja Hyeon; Lee, Joongyup; Kim, Seung Hyup

    2015-12-01

    The aim of the present study was to investigate the feasibility and image quality of excretory CT urography performed using low iodine-concentration contrast media and low tube voltage. This prospective study enrolled 63 patients who undergoing CT urography. The subjects were randomized into two groups of an excretory phase CT urography protocol and received either 240 mg I/mL of contrast media and 80 kVp of tube voltage (low-concentration protocol, n=32) or 350 mg I/mL and 120 kVp (conventional protocol, n=31). Two readers qualitatively evaluated images for sharpness of the urinary tract, image noise, streak artifact and overall diagnostic acceptability. The mean attenuation, signal-to-noise ratio, contrast-to-noise ratio and figure of merit were measured in the urinary tract. The non-inferiority test assessed the diagnostic acceptability between the two protocol groups. The low-concentration protocol showed a significantly lower effective radiation dose (3.44 vs. 5.70 mSv, P<.001). The diagnostic acceptability was significantly lower in the low-concentration protocol with iterative reconstruction algorithm than in the conventional protocol (4.06±0.45 vs. 4.50±0.37, P<.001), however, all subjects showed at least more than standard diagnostic acceptability and the difference resided in the predefined non-inferiority margin. The signal-to-noise ratio, contrast-to-noise ratio and figure of merit were significantly higher in the low-concentration protocol along the entire urinary tract (P<.001). CT urography using 240 mg I/mL iodine contrast media, 80 kVp tube voltage and an iterative reconstruction algorithm is beneficial to reduce radiation dose and iodine load, and its objective image quality and subjective diagnostic acceptability is not inferior to that of conventional CT urography. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Using Newborn Screening Bloodspots for Research: Public Preferences for Policy Options.

    PubMed

    Hayeems, Robin Z; Miller, Fiona A; Barg, Carolyn J; Bombard, Yvonne; Cressman, Celine; Painter-Main, Michael; Wilson, Brenda; Little, Julian; Allanson, Judith; Avard, Denise; Giguere, Yves; Chakraborty, Pranesh; Carroll, June C

    2016-06-01

    Retaining residual newborn screening (NBS) bloodspots for medical research remains contentious. To inform this debate, we sought to understand public preferences for, and reasons for preferring, alternative policy options. We assessed preferences among 4 policy options for research use of residual bloodspots through a bilingual national Internet survey of a representative sample of Canadians. Fifty percent of respondents were randomly assigned to select reasons supporting these preferences. Understanding of and attitudes toward screening and research concepts, and demographics were assessed. Of 1102 respondents (94% participation rate; 47% completion rate), the overall preference among policy options was ask permission (67%); this option was also the most acceptable choice (80%). Assume permission was acceptable to 46%, no permission required was acceptable to 29%, and no research allowed was acceptable to 26%. The acceptability of the ask permission option was reduced among participants assigned to the reasoning exercise (84% vs 76%; P = .004). Compared with assume/no permission required, ordered logistic regression showed a significant reduction in preference for the ask permission option with greater understanding of concepts (odds ratio, 0.87; P < .001), greater confidence in science (odds ratio, 0.16; P < .001), and a perceived responsibility to contribute to research (odds ratio, 0.39; P < .001). Surveyed Canadians prefer that explicit permission is sought for storage and research use of NBS bloodspots. This preference was diminished when reasons supporting and opposing routine storage, and other policy options, were presented. Findings warrant consideration as NBS communities strategize to respond to shifting legislative contexts. Copyright © 2016 by the American Academy of Pediatrics.

  20. Relationship between consumer ranking of lamb colour and objective measures of colour.

    PubMed

    Khliji, S; van de Ven, R; Lamb, T A; Lanza, M; Hopkins, D L

    2010-06-01

    Given the lack of data that relates consumer acceptance of lamb colour to instrument measures a study was undertaken to establish the acceptability thresholds for fresh and displayed meat. Consumers (n=541) were asked to score 20 samples of lamb loin (m.longissimus thoracis et lumborum; LL) on an ordinal scale of 1 (very acceptable) to 5 (very unacceptable). A sample was considered acceptable by a consumer if it scored three or less. Ten samples were used for testing consumer response to fresh colour and 10 to test consumer response to colour during display of up to 4days. The colour of fresh meat was measured using a Minolta chromameter with a closed cone and a Hunter Lab Miniscan was used for measuring meat on display. For fresh meat when the a( *) (redness) and L( *) (lightness) values are equal to or exceed 9.5 and 34, respectively, on average consumers will consider the meat colour acceptable. However a( *) and L( *) values must be much higher (14.5 and 44, respectively) to have 95% confidence that a randomly selected consumer will consider a sample acceptable. For aged meat, when the wavelength ratio (630/580nm) and the a( *) values are equal to or greater than 3.3 and 14.8, respectively, on average consumers will consider the meat acceptable. These thresholds need to be increased to 6.8 for ratio (630/580nm) and 21.7 for a( *) to be 95% confident that a randomly selected consumer will consider a sample acceptable. Crown Copyright 2010. Published by Elsevier Ltd. All rights reserved.

  1. A Novel High Performance Liquid Chromatographic Method for Simultaneous Determination of Ceftriaxone and Sulbactam in Sulbactomax

    PubMed Central

    Shrivastava, Sanjay Mohan; Singh, Rajkumar; Tariq, Abu; Siddiqui, Masoom Raza; Yadav, Jitendar; Negi, P. S.; Chaudhary, Manu

    2009-01-01

    An isocratic liquid chromatographic method with UV detection at 220 nm is described for simultaneous determination of ceftriaxone sodium and sulbactam sodium in Sulbactomax. Chromatographic separation of two drugs was achieved on a Hypersil ODS C-18 column using a mobile phase consisting of a binary mixture of acetonitrile and tetrabutyl ammonium hydroxide adjusted to pH7.0 with orthophosphoric acid in ratio 70:30. The developed Liquid Chromatographic method offers symmetric peak shape, good resolution and reasonable retention time for both drugs. Linearity, accuracy and precision were found to be acceptable over the concentration range of 125-750 ppm for ceftriaxone sodium and 62.5-375 ppm for sulbactam sodium. The LC method can be used for the quality control of formulated products containing ceftriaxone and sulbactam. PMID:23675112

  2. Accelerating the weighted histogram analysis method by direct inversion in the iterative subspace.

    PubMed

    Zhang, Cheng; Lai, Chun-Liang; Pettitt, B Montgomery

    The weighted histogram analysis method (WHAM) for free energy calculations is a valuable tool to produce free energy differences with the minimal errors. Given multiple simulations, WHAM obtains from the distribution overlaps the optimal statistical estimator of the density of states, from which the free energy differences can be computed. The WHAM equations are often solved by an iterative procedure. In this work, we use a well-known linear algebra algorithm which allows for more rapid convergence to the solution. We find that the computational complexity of the iterative solution to WHAM and the closely-related multiple Bennett acceptance ratio (MBAR) method can be improved by using the method of direct inversion in the iterative subspace. We give examples from a lattice model, a simple liquid and an aqueous protein solution.

  3. Mesophilic co-digestion of palm oil mill effluent and empty fruit bunches.

    PubMed

    Kim, Sang-Hyoun; Choi, Seon-Mi; Ju, Hyun-Jun; Jung, Jin-Young

    2013-01-01

    The palm oil mill industry generates palm oil mill effluent (POME) and empty fruit bunches (EFB) as by-products. This study reports the mesophilic co-digestion of POME with EFB. The biochemical methane potential (BMP) of POME and EFB was 0.397 L CH4/g volatile solids (VS) and 0.264 L CH4/g VS, respectively. In a series of batch tests at various EFB to POME ratios, the maximum methane production rate was achieved at an EFB:POME ratio of 0.25-0.31:1. Performance data from lab-scale digesters confirmed the positive synergism by the addition of EFB to POME, which was attributed to the balanced chemical composition, for example the chemical oxygen demand (COD) to total Kjeldahl nitrogen (TKN) ratio. The EFB addition enhanced the acceptable organic loading rate, methane production, COD removal, and microbial activity. The mesophilic co-digestion of POME and EFB promises to be a viable recycling method to alleviate pollution problems and recover renewable energy in the palm oil mill industry.

  4. Esthetic preferences of laypersons of different cultures and races with regard to smile attractiveness.

    PubMed

    Sadrhaghighi, Amir Houman; Zarghami, Afsaneh; Sadrhaghighi, Shahrzad; Mohammadi, Amir; Eskandarinezhad, Mahsa

    2017-01-01

    Culture and ethnicity are among the factors affecting esthetic judgment of individuals. This study aimed to assess the acceptability threshold of variations in four components of an esthetic smile namely vertical lip thickness, dental midline deviation, buccal corridor, and the golden ratio in maxillary lateral incisors display among laypersons of different races and cultures. Raters (n = 35 in each city) among laypersons of nine cities namely Istanbul, Isfahan, Tabriz, Tehran, Doha, Rome, Sydney, Chicago, and Yazd, were given a photo album containing 27 random images of an attractive female smile, digitally altered with regard to the four smile components. They scored each picture from 0 to 100 in terms of smile attractiveness. Data were analyzed using SPSS 13 and the acceptability threshold for each component was calculated in each city using the Spearman and Wilcoxon tests. P< 0.05 was considered statistically significant. No significant differences were noted with regard to the increased vertical lip thickness, and an acceptability threshold could not be determined for it. The acceptability thresholds for midline deviations, buccal corridor, and the golden ratio were different among different cities. One-millimeter increase in the displayed width of maxillary lateral incisors was more desirable than the golden ratio standard width. Culture and race may significantly affect the esthetic preference of individuals with regard to smile attractiveness.

  5. Image enhancement in positron emission mammography

    NASA Astrophysics Data System (ADS)

    Slavine, Nikolai V.; Seiler, Stephen; McColl, Roderick W.; Lenkinski, Robert E.

    2017-02-01

    Purpose: To evaluate an efficient iterative deconvolution method (RSEMD) for improving the quantitative accuracy of previously reconstructed breast images by commercial positron emission mammography (PEM) scanner. Materials and Methods: The RSEMD method was tested on breast phantom data and clinical PEM imaging data. Data acquisition was performed on a commercial Naviscan Flex Solo II PEM camera. This method was applied to patient breast images previously reconstructed with Naviscan software (MLEM) to determine improvements in resolution, signal to noise ratio (SNR) and contrast to noise ratio (CNR.) Results: In all of the patients' breast studies the post-processed images proved to have higher resolution and lower noise as compared with images reconstructed by conventional methods. In general, the values of SNR reached a plateau at around 6 iterations with an improvement factor of about 2 for post-processed Flex Solo II PEM images. Improvements in image resolution after the application of RSEMD have also been demonstrated. Conclusions: A rapidly converging, iterative deconvolution algorithm with a novel resolution subsets-based approach RSEMD that operates on patient DICOM images has been used for quantitative improvement in breast imaging. The RSEMD method can be applied to clinical PEM images to improve image quality to diagnostically acceptable levels and will be crucial in order to facilitate diagnosis of tumor progression at the earliest stages. The RSEMD method can be considered as an extended Richardson-Lucy algorithm with multiple resolution levels (resolution subsets).

  6. Comparative effectiveness, safety and acceptability of medical abortion at home and in a clinic: a systematic review

    PubMed Central

    Park, Min Hae; Shakur, Haleema; Free, Caroline

    2011-01-01

    Abstract Objective To compare medical abortion practised at home and in clinics in terms of effectiveness, safety and acceptability. Methods A systematic search for randomized controlled trials and prospective cohort studies comparing home-based and clinic-based medical abortion was conducted. The Cochrane Central Register of Controlled Trials, EMBASE, MEDLINE and Popline were searched. Failure to abort completely, side-effects and acceptability were the main outcomes of interest. Odds ratios and their 95% confidence intervals (CIs) were calculated. Estimates were pooled using a random-effects model. Findings Nine studies met the inclusion criteria (n = 4522 participants). All were prospective cohort studies that used mifepristone and misoprostol to induce abortion. Complete abortion was achieved by 86–97% of the women who underwent home-based abortion (n = 3478) and by 80–99% of those who underwent clinic-based abortion (n = 1044). Pooled analyses from all studies revealed no difference in complete abortion rates between groups (odds ratio = 0.8; 95% CI: 0.5–1.5). Serious complications from abortion were rare. Pain and vomiting lasted 0.3 days longer among women who took misoprostol at home rather than in clinic. Women who chose home-based medical abortion were more likely to be satisfied, to choose the method again and to recommend it to a friend than women who opted for medical abortion in a clinic. Conclusion Home-based abortion is safe under the conditions in place in the included studies. Prospective cohort studies have shown no differences in effectiveness or acceptability between home-based and clinic-based medical abortion across countries. PMID:21556304

  7. YouTube Video Educational Package Increased Acceptance of Antibiotic Clinical Decision Support System Recommendations

    PubMed Central

    Heng, Shi Thong; Tan, Michelle; Young, Barnaby; Lye, David; Ng, Tat Ming

    2017-01-01

    Abstract Background Antibiotic clinical decision support systems (CDSS) were implemented to provide stewardship at the point of ordering of broad-spectrum antibiotics (piperacillin-tazobactam and carbapenems). We postulated that a YouTube based educational video package (EP) with quizzes can help to improve CDSS acceptance. Methods A before-after study was conducted in general wards at Tan Tock Seng Hospital from April 2016 to March 2017. Baseline data were collected for 6 months before EP was implemented and during the next 6 months with EP dissemination to all doctors. Acceptance of CDSS recommendations between both phases were compared. Independent factors associated with acceptance of specific CDSS recommendations were identified by logistic regression. Results Patients recruited before and after EP was 1642 and 1313 respectively. Overall CDSS acceptance rate was similar before and after EP. There was improved acceptance for recommendations for dose optimizaton, antibiotic optimization and set duration (Figures 1 and 2). Independent factors of CDSS acceptance for dose optimizaton, antibiotic optimization and set duration are shown in Table 1. EP implementation was independently associated with acceptance of recommendations to set duration and optimize antibiotics. Conclusion EP was independently associated with increased CDSS acceptance on antibiotic duration and antibiotic optimization. Although acceptance of dose optimization was improved, EP was not associated independently with acceptance of the recommendations. Figure 2 Acceptance of CDSS recommendations by classifications of recommendations Table 1 3 multivariate models of acceptance of CDSS recommendations on antibiotic optimization, dose optimization and duration setting Set duration Antibiotic optimization Dose optimization Factor Odds ratio [95% CI] Lung infection 2.71[2.13–3.45] 2.08[1.71–2.52] 2.79[2.19-3.55] Unknown sepsis source 1.73[1.27–2.35] – 1.44[1.05-1.96] Piperacillin-tazobactam use 3.02[2.17–4.19] – – Temperature during initiation of antibiotics 0.86[0.79–0.94] – – The presence of oxygen supplementation during initiation of antibiotics – 0.76[0.64–0.91] 0.76[0.64–0.91] EP implementation 1.38[1.18–1.62] 1.21[1.02–1.43] - Disclosures All authors: No reported disclosures.

  8. Factors Affecting the Designation of Cerebrovascular Diseases as Work-Related in Administrative Litigation

    PubMed Central

    Kim, Hyeongsu; Rim, Hwayoung; Chang, Sounghoon; Lee, Kunsei

    2008-01-01

    The purpose of this study was to identify factors that could be used as standardized criteria for evaluating occupational diseases in initial assessments or requests for examination. Using 100 administrative litigation cases on the work-relatedness of cerebrovascular diseases (CVDs) by the Seoul Branch of the Korea Labor Welfare Corporation (KLWC) from 1997 to 2002, we estimated the relationship between the investigated variables and designation of the work-relatedness of the CVD. As for the age, the odds ratio of the acceptance rate of a case as work-related in subjects over 60 yr of age was 0.08 (95% CI, 0.01-0.75), which was compared to subjects under 30 yr of age. Regarding working hours, the odds ratio of the acceptance rate of a case as work-related in CVDs in those over 56 hr was 9.50 (95% CI, 1.92-47.10) when compared to those less than 56 hr. As for the benefit type, the odds ratio of the acceptance rate of a case as work-related in medical benefits was 5.74 (95% CI, 1.29-25.54), compared to survivor benefits. As for the criteria for defining situations as work overload, the odds ratio of the acceptance rate of a case as work-related in injured workers was 12.06 (95% CI, 3.12-46.62), compared to that in non-injured workers. Our findings show that the criteria for defining situations of work overload played an important role in assessing the work-relatedness of CVDs in administrative litigation, and it is necessary to make the scientific evidence on judgement of work-relatedness on overwork. PMID:18437006

  9. Estimation of simvastatin and cetirizine by RP-LC method: Application to freeze and thaw (FT) stability studies.

    PubMed

    Naveed, Safila; Usmanghani, Khan; Sana, Aisha; Ali, Huma; Zafar, Farya; Qamar, Fatima; Sarwer, Ghulam; Abbas, Sarah; Alam, M Tanweer; Shinwari, Muhammad Ibrar

    2018-01-01

    Sensitive, simple, reliable and rapid HPLC technique for the estimation of simvastatin (SMV) and cetirizine has been designed in this study. The chromatographic conditions were set using Shimadzu LC-10 AT VP pump, with UV detector (SPD-10 AV-VP). System integration was performed with CBM-102 (Bus Module). Partitioning of components was attained with pre-packed C-18 column of Purospher Star (5 μm, 250 x 4.6 mm) at ambient conditions. Injected volume of sample was 10 μl. Mobile phase was composed of 50:50 v/v ratio of Acetonitrile/water (pH 3.0 adjusted with ortho-phosphoric acid) having 2 ml/minutes rate of flow. Compounds were detected in UV region at 225 nm. Percent Recovery of simvastatin was observed in the range of 98-102%. All results were found in accept table range of specification. The projected method is consistent, specific, precise, and rapid, that can be employed to quantitate the SMV along with cetirizine HCl. It was estimated by 3 successive cycles of freeze and thaw stability. Results of FT samples were found within accept table limits the method was developed and validated in raw materials, bulk formulations and final drug products.

  10. Probabilistic framework for assessing the arsenic exposure risk from cooked fish consumption.

    PubMed

    Ling, Min-Pei; Wu, Chiu-Hua; Chen, Szu-Chieh; Chen, Wei-Yu; Chio, Chia-Pin; Cheng, Yi-Hsien; Liao, Chung-Min

    2014-12-01

    Geogenic arsenic (As) contamination of groundwater is a major ecological and human health problem in southwestern and northeastern coastal areas of Taiwan. Here, we present a probabilistic framework for assessing the human health risks from consuming raw and cooked fish that were cultured in groundwater As-contaminated ponds in Taiwan by linking a physiologically based pharmacokinetics model and a Weibull dose-response model. Results indicate that As levels in baked, fried, and grilled fish were higher than those of raw fish. Frying resulted in the greatest increase in As concentration, followed by grilling, with baking affecting the As concentration the least. Simulation results show that, following consumption of baked As-contaminated fish, the health risk to humans is <10(-6) excess bladder cancer risk level for lifetime exposure; as the incidence ratios of liver and lung cancers are generally acceptable at risk ranging from 10(-6) to 10(-4), the consumption of baked As-contaminated fish is unlikely to pose a significant risk to human health. However, contaminated fish cooked by frying resulted in significant health risks, showing the highest cumulative incidence ratios of liver cancer. We also show that males have higher cumulative incidence ratio of liver cancer than females. We found that although cooking resulted in an increase for As levels in As-contaminated fish, the risk to human health of consuming baked fish is nevertheless acceptable. We suggest the adoption of baking as a cooking method and warn against frying As-contaminated fish. We conclude that the concentration of contaminants after cooking should be taken into consideration when assessing the risk to human health.

  11. Assessing the potential effects and cost-effectiveness of programmatic herpes zoster vaccination of elderly in the Netherlands

    PubMed Central

    2010-01-01

    Background Herpes zoster (HZ) is a painful disease affecting a considerable part of the elderly. Programmatic HZ vaccination of elderly people may considerably reduce HZ morbidity and its related costs, but the extent of these effects is unknown. In this article, the potential effects and cost-effectiveness of programmatic HZ vaccination of elderly in the Netherlands have been assessed according to a framework that was developed to support evidence-based decision making regarding inclusion of new vaccines in the Dutch National Immunization Program. Methods An analytical framework was used combining a checklist, which structured relevant data on the vaccine, pathogen and disease, and a cost-effectiveness analysis. The cost-effectiveness analysis was performed from a societal perspective, using a Markov-cohort-model. Simultaneous vaccination with influenza was assumed. Results Due to the combination of waning immunity after vaccination and a reduced efficacy of vaccination at high ages, the most optimal cost-effectiveness ratio (€21716 per QALY) for HZ vaccination in the Netherlands was found for 70-year olds. This estimated ratio is just above the socially accepted threshold in the Netherlands of €20000 per QALY. If additional reduction of postherpetic neuralgia was included, the cost-effectiveness ratio improved (~€10000 per QALY) but uncertainty for this scenario is high. Conclusions Vaccination against HZ at the age of 70 years seems marginally cost-effective in the Netherlands. Due to limited vaccine efficacy a considerable part of the disease burden caused by HZ will remain, even with optimal acceptance of programmatic vaccination. PMID:20707884

  12. Parental acceptability of contraceptive methods offered to their teen during a confidential health care visit.

    PubMed

    Hartman, Lauren B; Shafer, Mary-Ann; Pollack, Lance M; Wibbelsman, Charles; Chang, Fay; Tebb, Kathleen P

    2013-02-01

    To examine parental acceptability of contraceptive methods offered confidentially to their adolescent daughter. A random sample of 261 parents/guardians with a daughter aged 12-17 years completed a telephone survey examining the relationship between parental acceptability of seven contraceptive methods and adolescents' likelihood to have sex, parenting beliefs, parents' sexual health as teens, sexually transmitted infection knowledge, and demographic factors. Acceptability was highest for oral contraceptive pills (59%) and lowest for intrauterine device (18%). Parental acceptance of teens' autonomy was significantly associated with increased acceptability of all methods. Parental knowledge of sexually transmitted infections was poor, and 51% found it acceptable for clinicians to provide their sexually active teen with condoms. Parents were more accepting of oral contraceptive pills and condoms compared with intrauterine devices and implants. Parental recognition of their teen's autonomy was associated with greater parental acceptability of clinicians providing their adolescent with contraceptives (regardless of the specific type of method being offered). Copyright © 2013 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  13. Joint distribution approaches to simultaneously quantifying benefit and risk.

    PubMed

    Shaffer, Michele L; Watterberg, Kristi L

    2006-10-12

    The benefit-risk ratio has been proposed to measure the tradeoff between benefits and risks of two therapies for a single binary measure of efficacy and a single adverse event. The ratio is calculated from the difference in risk and difference in benefit between therapies. Small sample sizes or expected differences in benefit or risk can lead to no solution or problematic solutions for confidence intervals. Alternatively, using the joint distribution of benefit and risk, confidence regions for the differences in risk and benefit can be constructed in the benefit-risk plane. The information in the joint distribution can be summarized by choosing regions of interest in this plane. Using Bayesian methodology provides a very flexible framework for summarizing information in the joint distribution. Data from a National Institute of Child Health & Human Development trial of hydrocortisone illustrate the construction of confidence regions and regions of interest in the benefit-risk plane, where benefit is survival without supplemental oxygen at 36 weeks postmenstrual age, and risk is gastrointestinal perforation. For the subgroup of infants exposed to chorioamnionitis the confidence interval based on the benefit-risk ratio is wide (Benefit-risk ratio: 1.52; 90% confidence interval: 0.23 to 5.25). Choosing regions of appreciable risk and acceptable risk in the benefit-risk plane confirms the uncertainty seen in the wide confidence interval for the benefit-risk ratio--there is a greater than 50% chance of falling into the region of acceptable risk--while visually allowing the uncertainty in risk and benefit to be shown separately. Applying Bayesian methodology, an incremental net health benefit analysis shows there is a 72% chance of having a positive incremental net benefit if hydrocortisone is used in place of placebo if one is willing to incur at most one gastrointestinal perforation for each additional infant that survives without supplemental oxygen. If the benefit-risk ratio is presented, the joint distribution of benefit and risk also should be shown. These regions avoid the ambiguity associated with collapsing benefit and risk to a single dimension. Bayesian methods allow even greater flexibility in simultaneously quantifying benefit and risk.

  14. A double-spike method for K-Ar measurement: A technique for high precision in situ dating on Mars and other planetary surfaces

    NASA Astrophysics Data System (ADS)

    Farley, K. A.; Hurowitz, J. A.; Asimow, P. D.; Jacobson, N. S.; Cartwright, J. A.

    2013-06-01

    A new method for K-Ar dating using a double isotope dilution technique is proposed and demonstrated. The method is designed to eliminate known difficulties facing in situ dating on planetary surfaces, especially instrument complexity and power availability. It may also have applicability in some terrestrial dating applications. Key to the method is the use of a solid tracer spike enriched in both 39Ar and 41K. When mixed with lithium borate flux in a Knudsen effusion cell, this tracer spike and a sample to be dated can be successfully fused and degassed of Ar at <1000 °C. The evolved 40Ar∗/39Ar ratio can be measured to high precision using noble gas mass spectrometry. After argon measurement the sample melt is heated to a slightly higher temperature (˜1030 °C) to volatilize potassium, and the evolved 39K/41K ratio measured by Knudsen effusion mass spectrometry. Combined with the known composition of the tracer spike, these two ratios define the K-Ar age using a single sample aliquot and without the need for extreme temperature or a mass determination. In principle the method can be implemented using a single mass spectrometer. Experiments indicate that quantitative extraction of argon from a basalt sample occurs at a sufficiently low temperature that potassium loss in this step is unimportant. Similarly, potassium isotope ratios measured in the Knudsen apparatus indicate good sample-spike equilibration and acceptably small isotopic fractionation. When applied to a flood basalt from the Viluy Traps, Siberia, a K-Ar age of 351 ± 19 Ma was obtained, a result within 1% of the independently known age. For practical reasons this measurement was made on two separate mass spectrometers, but a scheme for combining the measurements in a single analytical instrument is described. Because both parent and daughter are determined by isotope dilution, the precision on K-Ar ages obtained by the double isotope dilution method should routinely approach that of a pair of isotope ratio determinations, likely better than ±5%.

  15. Qualitative methods to ensure acceptability of behavioral and social interventions to the target population

    PubMed Central

    Ayala, Guadalupe X.; Elder, John P.

    2013-01-01

    This paper introduces qualitative methods for assessing the acceptability of an intervention. Acceptability refers to determining how well an intervention will be received by the target population and the extent to which the new intervention or its components might meet the needs of the target population and organizational setting. In this paper, we focus on two common qualitative methods for conducting acceptability research and their advantages and disadvantages: focus groups and interviews. We provide examples from our own research and other studies to demonstrate the use of these methods for conducting acceptability research and how one might adapt this approach for oral health research. Finally, we present emerging methods for conducting acceptability research, including the use of community-based participatory research, as well as the utility of conducting acceptability research for assessing the appropriateness of measures in intervention research. PMID:21656958

  16. Multi-energy Coordinated Evaluation for Energy Internet

    NASA Astrophysics Data System (ADS)

    Jia, Dongqiang; Sun, Jian; Wang, Cunping; Hong, Xiao; Ma, Xiufan; Xiong, Wenting; Shen, Yaqi

    2017-05-01

    This paper reviews the current research status of multi-energy coordinated evaluation for energy Internet. Taking the coordinated optimization effect of wind energy, solar energy and other energy sources into consideration, 17 evaluation indexes, such as the substitution coefficient of cold heat and power, the ratio of wind and solar energy, and the rate of energy storage ratio, were designed from five aspects, including the acceptance of renewable energy, energy complementary alternative benefits, peak valley difference, the degree of equipment utilization and user needs. At the same time, this article attaches importance to the economic and social benefits of the coordination of multiple energy sources. Ultimately, a comprehensive multi-energy coordination evaluation index system of regional energy Internet was put forward from the safe operation, coordination and optimization, economic and social benefits four aspects, and a comprehensive evaluation model was established. This model uses the optimal combination weighting method based on moment estimation and Topsis evaluation analysis method, so both the subjective and objective weight of the index are considered and the coordinate evaluation of multi-energy is realized. Finally the perfection of the index system and the validity of the evaluation method are verified by a case analysis.

  17. Low-lift-to-drag-ratio approach and landing studies using a CV-990 airplane

    NASA Technical Reports Server (NTRS)

    Kock, B. M.; Fulton, F. L.; Drinkwater, F. J., III

    1972-01-01

    The results are presented of a flight-test program utilizing a CV-990 airplane, flow in low-lift-to-drag-ratio (L/D) configurations, to simulate terminal area operation, approach, and landing of large unpowered vehicles. The results indicate that unpowered approaches and landings are practical with vehicles of the size and performance characteristics of the proposed shuttle vehicle. Low L/D landings provided touchdown dispersion patterns acceptable for operation on runways of reasonable length. The dispersion pattern was reduced when guidance was used during the final approach. High levels of pilot proficiency were not required for acceptable performance.

  18. Sap flow sensors: construction, quality control and comparison.

    PubMed

    Davis, Tyler W; Kuo, Chen-Min; Liang, Xu; Yu, Pao-Shan

    2012-01-01

    This work provides a design for two types of sensors, based on the thermal dissipation and heat ratio methods of sap flow calculation, for moderate to large scale deployments for the purpose of monitoring tree transpiration. These designs include a procedure for making these sensors, a quality control method for the final products, and a complete list of components with vendors and pricing information. Both sensor designs were field tested alongside a commercial sap flow sensor to assess their performance and show the importance for quality controlling the sensor outputs. Results show that for roughly 2% of the cost of commercial sensors, self-made sap flow sensors can provide acceptable estimates of the sap flow measurements compared to the commercial sensors.

  19. An Evaluation of Automotive Interior Packages Based on Human Ocular and Joint Motor Properties

    NASA Astrophysics Data System (ADS)

    Tanaka, Yoshiyuki; Rakumatsu, Takeshi; Horiue, Masayoshi; Miyazaki, Tooru; Nishikawa, Kazuo; Nouzawa, Takahide; Tsuji, Toshio

    This paper proposes a new evaluation method of an automotive interior package based on human oculomotor and joint-motor properties. Assuming the long-term driving situation in the express high way, the three evaluation indices were designed on i) the ratio of head motion at gazing the driving items; ii) the load torque for maintaining the standard driving posture; and iii) the human force manipulability at the end-point of human extremities. Experiments were carried out for two different interior packages with four subjects who have the special knowledge on the automobile development. Evaluation results demonstrate that the proposed method can quantitatively analyze the driving interior in good agreement with the generally accepted subjective opinion in the automobile industry.

  20. Evaluation and optimization of the optical performance of low-concentrating dielectric compound parabolic concentrator using ray-tracing methods.

    PubMed

    Sarmah, Nabin; Richards, Bryce S; Mallick, Tapas K

    2011-07-01

    We present a detailed design concept and optical performance evaluation of stationary dielectric asymmetric compound parabolic concentrators (DiACPCs) using ray-tracing methods. Three DiACPC designs, DiACPC-55, DiACPC-66, and DiACPC-77, of acceptance half-angles (0° and 55°), (0° and 66°), and (0° and 77°), respectively, are designed in order to optimize the concentrator for building façade photovoltaic applications in northern latitudes (>55 °N). The dielectric concentrator profiles have been realized via truncation of the complete compound parabolic concentrator profiles to achieve a geometric concentration ratio of 2.82. Ray-tracing simulation results show that all rays entering the designed concentrators within the acceptance half-angle range can be collected without escaping from the parabolic sides and aperture. The maximum optical efficiency of the designed concentrators is found to be 83%, which tends to decrease with the increase in incidence angle. The intensity is found to be distributed at the receiver (solar cell) area in an inhomogeneous pattern for a wide range of incident angles of direct solar irradiance with high-intensity peaks at certain points of the receiver. However, peaks become more intense for the irradiation incident close to the extreme acceptance angles, shifting the peaks to the edge of the receiver. Energy flux distribution at the receiver for diffuse radiation is found to be homogeneous within ±12% with an average intensity of 520 W/m².

  1. Theoretical and experimental study of polycyclic aromatic compounds as β-tubulin inhibitors.

    PubMed

    Olazarán, Fabian E; García-Pérez, Carlos A; Bandyopadhyay, Debasish; Balderas-Rentería, Isaias; Reyes-Figueroa, Angel D; Henschke, Lars; Rivera, Gildardo

    2017-03-01

    In this work, through a docking analysis of compounds from the ZINC chemical library on human β-tubulin using high performance computer cluster, we report new polycyclic aromatic compounds that bind with high energy on the colchicine binding site of β-tubulin, suggesting three new key amino acids. However, molecular dynamic analysis showed low stability in the interaction between ligand and receptor. Results were confirmed experimentally in in vitro and in vivo models that suggest that molecular dynamics simulation is the best option to find new potential β-tubulin inhibitors. Graphical abstract Bennett's acceptance ratio (BAR) method.

  2. Soy-yamgurt probiotic drink as a natural potential of antioxidant

    NASA Astrophysics Data System (ADS)

    Rusmarilin, H.; Nurhasanah; Andayani, RY

    2018-02-01

    Yogurt is a popular healthy food, consumed by many people. Probiotic are used for better growth and survival of probiotic bacteria as well as to improve organoleptic, rheological and technological properties of soy-yamgurt probiotic. The aims of this study were to determine physicochemical changes and survival of probiotic bacteria due to the effect of ratio of yam-bean with soy-bean extract on the quality of soy-yamgurt probiotic drink. The quality examined were total bacteria, antioxidant activity, lactic acid content, and acceptability including color, texture, flavor, and overall acceptance. This research had been performed using Completely Randomized Design two factorials, consist of five levels i.e.: ratio of yam-bean with soy-bean extract (100:0; 75:25; 50:50; 25:75; 0:100) and the fermentation time (4,6 and 8 hours), the process was repeated three times. The results showed that ratio of yam-bean with soy-bean extract of 50:50 and fermentation for 6 hours incubation produced the best quality. Acceptable probiotic drink containing 1.44 x 109 CFU/mL lactic acid bacteria, IC50 of soy-yamgurt in the attenuation of free radical DPPH ranged from 58.718-18.112 mg/L in 5 minutes incubation and 39.7204-11.9925 mg/L in 60 minutes, and 0.48% lactic acid. This appearance of soy-yamgurt had yellow greenish color, desired texture and flavor, and received the highest score of overall acceptance.

  3. Does the Mother or Father Determine the Offspring Sex Ratio? Investigating the Relationship between Maternal Digit Ratio and Offspring Sex Ratio

    PubMed Central

    Kim, Tae Beom; Oh, Jin Kyu; Kim, Kwang Taek; Yoon, Sang Jin; Kim, Soo Woong

    2015-01-01

    Objective In mammals, high parental testosterone levels present around the time of conception are thought to skew offspring sex ratio toward sons. The second to fourth digit ratio (digit ratio) is now widely accepted as a negative correlate of prenatal testosterone. Thus, we investigated the association between digit ratio and offspring sex ratio. Methods A total of 508 Korean patients (257 males and 251 females) less than 60 years old who had one or more offspring were prospectively enrolled. The lengths of the 2nd and 4th digits of the right hand were measured by a single investigator using a digital vernier calliper. Next, the patients’ lifetime offspring birth sex ratios were investigated. Results Maternal (rather than paternal) digit ratio was significantly associated with the number of sons (r = -0.153, p = 0.015), number of daughters (r = 0.130, p = 0.039), and offspring sex ratio (r = -0.171, p = 0.007). And, the maternal digit ratio was a significant factor for predicting offspring sex ratio (B = -1.620, p = 0.008) on multiple linear regression analysis. The female patients with a lower digit ratio (< 0.95) were found to have a higher offspring sex ratio (0.609 versus 0.521, p = 0.046) compared to those with a higher digit ratio (≥ 0.95). Furthermore, females in the low digit ratio group have a probability 1.138 greater of having sons than females in the high digit ratio group. Conclusions Maternal digit ratio was negatively associated with offspring sex ratio. Females with a lower digit ratio were more likely to have more male offspring compared to those with a higher digit ratio. Thus, our results suggest that the sex of offspring might be more influenced by maternal rather than paternal factors. PMID:26575995

  4. Optimizing probability of detection point estimate demonstration

    NASA Astrophysics Data System (ADS)

    Koshti, Ajay M.

    2017-04-01

    The paper provides discussion on optimizing probability of detection (POD) demonstration experiments using point estimate method. The optimization is performed to provide acceptable value for probability of passing demonstration (PPD) and achieving acceptable value for probability of false (POF) calls while keeping the flaw sizes in the set as small as possible. POD Point estimate method is used by NASA for qualifying special NDE procedures. The point estimate method uses binomial distribution for probability density. Normally, a set of 29 flaws of same size within some tolerance are used in the demonstration. Traditionally largest flaw size in the set is considered to be a conservative estimate of the flaw size with minimum 90% probability and 95% confidence. The flaw size is denoted as α90/95PE. The paper investigates relationship between range of flaw sizes in relation to α90, i.e. 90% probability flaw size, to provide a desired PPD. The range of flaw sizes is expressed as a proportion of the standard deviation of the probability density distribution. Difference between median or average of the 29 flaws and α90 is also expressed as a proportion of standard deviation of the probability density distribution. In general, it is concluded that, if probability of detection increases with flaw size, average of 29 flaw sizes would always be larger than or equal to α90 and is an acceptable measure of α90/95PE. If NDE technique has sufficient sensitivity and signal-to-noise ratio, then the 29 flaw-set can be optimized to meet requirements of minimum required PPD, maximum allowable POF, requirements on flaw size tolerance about mean flaw size and flaw size detectability requirements. The paper provides procedure for optimizing flaw sizes in the point estimate demonstration flaw-set.

  5. INTEGRAL REACTION RATES AND NEUTRON ENERGY SPECTRA IN A WELL MODERATED REACTOR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Connolly, J.W.; Rose, A.; Wall, T.

    1963-04-01

    Cadmium ratio measurements in the internal reflector of MOATA were made with gold, indium, tungsten, manganese, molybdenum, and copper detectors. These measurements were analyzed on the assumption that the neutron spectrum consists of a Maxwellian distribution to which is smoothly joined a 1/E slowing down spectrum, the cross sections being averaged according to the methods of Westcott. A search through recent literature suggests that the s factors for gold and indium listed by Westcott are in error. If this is accepted, then it appears that the measured epithermal spectrum is closely 1/E in form for neutron energies between 1 andmore » 600 ev. The corrections to be applied when foils of finite thickness are used in cadmium ratio measuremerts are discussed, and the spectrum derived from these measurements was used to calculate reaction rate ratios of copper: indium and copper: gold alloy foils. These ratios were compared with measured values. Values of the effective resonance integral of Pt/sup 198/ wire detectors were measured, and from these values an estimate was made of the infinitely dilute resonance integral of this isotope. (auth)« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marleau, Peter; Monterial, Mateusz; Clarke, Shaun

    A Bayesian approach is proposed for pulse shape discrimination of photons and neutrons in liquid organic scinitillators. Instead of drawing a decision boundary, each pulse is assigned a photon or neutron confidence probability. In addition, this allows for photon and neutron classification on an event-by-event basis. The sum of those confidence probabilities is used to estimate the number of photon and neutron instances in the data. An iterative scheme, similar to an expectation-maximization algorithm for Gaussian mixtures, is used to infer the ratio of photons-to-neutrons in each measurement. Therefore, the probability space adapts to data with varying photon-to-neutron ratios. Amore » time-correlated measurement of Am–Be and separate measurements of 137Cs, 60Co and 232Th photon sources were used to construct libraries of neutrons and photons. These libraries were then used to produce synthetic data sets with varying ratios of photons-to-neutrons. Probability weighted method that we implemented was found to maintain neutron acceptance rate of up to 90% up to photon-to-neutron ratio of 2000, and performed 9% better than the decision boundary approach. Furthermore, the iterative approach appropriately changed the probability space with an increasing number of photons which kept the neutron population estimate from unrealistically increasing.« less

  7. Definition and Measurement of Selection Bias: From Constant Ratio to Constant Difference

    ERIC Educational Resources Information Center

    Cahan, Sorel; Gamliel, Eyal

    2006-01-01

    Despite its intuitive appeal and popularity, Thorndike's constant ratio (CR) model for unbiased selection is inherently inconsistent in "n"-free selection. Satisfaction of the condition for unbiased selection, when formulated in terms of success/acceptance probabilities, usually precludes satisfaction by the converse probabilities of…

  8. Computational Analysis on Performance of Thermal Energy Storage (TES) Diffuser

    NASA Astrophysics Data System (ADS)

    Adib, M. A. H. M.; Adnan, F.; Ismail, A. R.; Kardigama, K.; Salaam, H. A.; Ahmad, Z.; Johari, N. H.; Anuar, Z.; Azmi, N. S. N.

    2012-09-01

    Application of thermal energy storage (TES) system reduces cost and energy consumption. The performance of the overall operation is affected by diffuser design. In this study, computational analysis is used to determine the thermocline thickness. Three dimensional simulations with different tank height-to-diameter ratio (HD), diffuser opening and the effect of difference number of diffuser holes are investigated. Medium HD tanks simulations with double ring octagonal diffuser show good thermocline behavior and clear distinction between warm and cold water. The result show, the best performance of thermocline thickness during 50% time charging occur in medium tank with height-to-diameter ratio of 4.0 and double ring octagonal diffuser with 48 holes (9mm opening ~ 60%) acceptable compared to diffuser with 6mm ~ 40% and 12mm ~ 80% opening. The conclusion is computational analysis method are very useful in the study on performance of thermal energy storage (TES).

  9. The effect of variable S/N on the subjective evaluation of protection ratios for direct-TV satellite services

    NASA Technical Reports Server (NTRS)

    Groumpos, P. P.; Dimitriadis, B. D.; Whyte, W.

    1984-01-01

    Protection ratios, the ratio of wanted-to-unwanted signal power at the receiver input, for acceptable picture quality were experimentally evaluated for four different still pictures. The variation of carrier-to-interference, C/I, with picture impairment grade is investigated when different noise levels are present. Results are presented which show the relationship between the impairment grade and the C/I ratio for FM/TV co-channel systems under variable S/N conditions.

  10. DEEM, a versatile platform of FRD measurement for highly multiplexed fibre systems in astronomy

    NASA Astrophysics Data System (ADS)

    Yan, Yunxiang; Yan, Qi; Wang, Gang; Sun, Weimin; Luo, A.-Li; Ma, Zhenyu; Zhang, Qiong; Li, Jian; Wang, Shuqing

    2018-06-01

    We present a new method of DEEM, the direct energy encircling method, for characterizing the performance of fibres in most astronomical spectroscopic applications. It is a versatile platform to measure focal ratio degradation (FRD), throughput, and point spread function. The principle of DEEM and the relation between the encircled energy and the spot size were derived and simulated based on the power distribution model (PDM). We analysed the errors of DEEM and pointed out the major error source for better understanding and optimization. The validation of DEEM has been confirmed by comparing the results with conventional method which shows that DEEM has good robustness with high accuracy in both stable and complex experiment environments. Applications on the integral field unit (IFU) show that the FRD of 50 μm core fibre is substandard for the requirement which requires the output focal ratio to be slower than 4.5. The homogeneity of throughput is acceptable and higher than 85 per cent. The prototype IFU of the first generation helps to find out the imperfections to optimize the new design of the next generation based on the staggered structure with 35 μm core fibres of N.A. = 0.12, which can improve the FRD performance. The FRD dependence on wavelength and core size is revealed that higher output focal ratio occurs at shorter wavelengths for large core fibres, which is in agreement with the prediction of PDM. But the dependence of the observed data is weaker than the prediction.

  11. Assessment of the influence of energy under-reporting on intake estimates of four food additives.

    PubMed

    Gilsenan, M B; Gibney, M J

    2004-03-01

    Under-reporting has been identified as an important source of uncertainty in food chemical exposure assessments. The objective of the present study was to assess the influence of under-reporting on food additive intake estimates. Dietary survey data were derived from the North-South Ireland Food Consumption Survey (2001). Data from the Republic of Ireland (n = 958) were used. Energy under-reporters were identified using a ratio of energy intakes to estimated basal metabolic rate. First, food categories (n = 26) included in an assessment of exposure of four food additives were created and patterns of food intakes (i.e. likelihood of consumption, frequency of consumption and reported portion size) between acceptable and under-reporters compared. Second, for each food additive, deterministic intake estimates for the total sample (i.e. acceptable and under-reporters), under-reporters and acceptable reporters were calculated and compared. Differential reporting of the majority of food categories between acceptable and under-reporters was recorded. Under-reporters were less likely to record the consumption of a given food and more likely to under-report the frequency of consumption and portion size compared with acceptable reporters. Food additive intake estimates amongst acceptable reporters were higher than corresponding intake estimates amongst the total sample of reporters and amongst under-reporters. With the exception of one food additive (erythrosine), ratios of upper percentile additive intakes amongst acceptable reporters to corresponding intake estimates amongst the total sample of reporters did not exceed 1.06 when results were expressed as total population or consumer-only intakes. Findings illustrated that energy under-reporting does not materially influence estimates of food additive exposure based on the four food additives studied. However, a number of situations were identified where the under-reporting might exert a more significant impact on resulting exposure estimates.

  12. Fabrication method to create high-aspect ratio pillars for photonic coupling of board level interconnects

    NASA Astrophysics Data System (ADS)

    Debaes, C.; Van Erps, J.; Karppinen, M.; Hiltunen, J.; Suyal, H.; Last, A.; Lee, M. G.; Karioja, P.; Taghizadeh, M.; Mohr, J.; Thienpont, H.; Glebov, A. L.

    2008-04-01

    An important challenge that remains to date in board level optical interconnects is the coupling between the optical waveguides on printed wiring boards and the packaged optoelectronics chips, which are preferably surface mountable on the boards. One possible solution is the use of Ball Grid Array (BGA) packages. This approach offers a reliable attachment despite the large CTE mismatch between the organic FR4 board and the semiconductor materials. Collimation via micro-lenses is here typically deployed to couple the light vertically from the waveguide substrate to the optoelectronics while allowing for a small misalignment between board and package. In this work, we explore the fabrication issues of an alternative approach in which the vertical photonic connection between board and package is governed by a micro-optical pillar which is attached both to the board substrate and to the optoelectronic chips. Such an approach allows for high density connections and small, high-speed detector footprints while maintaining an acceptable tolerance between board and package. The pillar should exhibit some flexibility and thus a high-aspect ratio is preferred. This work presents and compares different fabrication methods and applies different materials for such high-aspect ratio pillars. The different fabrication methods are: photolithography, direct laser writing and deep proton writing. The selection of optical materials that was investigated is: SU8, Ormocers, PU and a multifunctional acrylate polymer. The resulting optical pillars have diameters ranging from 20um up to 80um, with total heights ranging between 30um and 100um (symbol for micron). The aspect-ratio of the fabricated structures ranges from 1.5 to 5.

  13. Validated stability-indicating spectrophotometric methods for the determination of Silodosin in the presence of its degradation products.

    PubMed

    Boltia, Shereen A; Abdelkawy, Mohammed; Mohammed, Taghreed A; Mostafa, Nahla N

    2018-09-05

    Five simple, rapid, accurate, and precise spectrophotometric methods are developed for the determination of Silodosin (SLD) in the presence of its acid induced and oxidative induced degradation products. Method A is based on dual wavelength (DW) method; two wavelengths are selected at which the absorbance of the oxidative induced degradation product is the same, so wavelengths 352 and 377 nm are used to determine SLD in the presence of its oxidative induced degradation product. Method B depends on induced dual wavelength theory (IDW), which is based on selecting two wavelengths on the zero-order spectrum of SLD where the difference in absorbance between them for the spectrum of acid induced degradation products is not equal to zero so through multiplying by the equality factor, the absorption difference is made to be zero for the acid induced degradation product while it is still significant for SLD. Method C is first derivative ( 1 D) spectrophotometry of SLD and its degradation products. Peak amplitudes are measured at 317 and 357 nm. Method D is ratio difference spectrophotometry (RD) where the drug is determined by the difference in amplitude between two selected wavelengths, at 350 and 277 nm for the ratio spectrum of SLD and its acid induced degradation products while for the ratio spectrum of SLD and its oxidative induced degradation products the difference in amplitude is measured at 345 and 292 nm. Method E depends on measuring peak amplitudes of the first derivative of the ratio ( 1 DD) where peak amplitudes are measured at 330 nm in the presence of the acid induced degradation product and measured by peak to peak technique at 326 and 369 nm in the presence of the oxidative induced degradation product. The proposed methods are validated according to ICH recommendations. The calibration curves for all the proposed methods are linear over a concentration range of 5-70 μg/mL. The selectivity of the proposed methods was tested using different laboratory prepared mixtures of SLD with either its acid induced or oxidative induced degradation products showing specificity of SLD with accepted recovery values. The proposed methods have been successfully applied to the analysis of SLD in pharmaceutical dosage forms without interference from additives. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Potassium Isotopic Compositions of NIST Potassium Standards and 40Ar/39Ar Mineral Standards

    NASA Technical Reports Server (NTRS)

    Morgan, Leah; Tappa, Mike; Ellam, Rob; Mark, Darren; Higgins, John; Simon, Justin I.

    2013-01-01

    Knowledge of the isotopic ratios of standards, spikes, and reference materials is fundamental to the accuracy of many geochronological methods. For example, the 238U/235U ratio relevant to U-Pb geochronology was recently re-determined [1] and shown to differ significantly from the previously accepted value employed during age determinations. These underlying values are fundamental to accurate age calculations in many isotopic systems, and uncertainty in these values can represent a significant (and often unrecognized) portion of the uncertainty budget for determined ages. The potassium isotopic composition of mineral standards, or neutron flux monitors, is a critical, but often overlooked component in the calculation of K-Ar and 40Ar/39Ar ages. It is currently assumed that all terrestrial materials have abundances indistinguishable from that of NIST SRM 985 [2]; this is apparently a reasonable assumption at the 0.25per mille level (1s) [3]. The 40Ar/39Ar method further relies on the assumption that standards and samples (including primary and secondary standards) have indistinguishable 40K/39K values. We will present data establishing the potassium isotopic compositions of NIST isotopic K SRM 985, elemental K SRM 999b, and 40Ar/39Ar biotite mineral standard GA1550 (sample MD-2). Stable isotopic compositions (41K/39K) were measured by the peak shoulder method with high resolution MC-ICP-MS (Thermo Scientific NEPTUNE Plus), using the accepted value of NIST isotopic SRM 985 [2] for fractionation [4] corrections [5]. 40K abundances were measured by TIMS (Thermo Scientific TRITON), using 41K/39K values from ICP-MS measurements (or, for SRM 985, values from [2]) for internal fractionation corrections. Collectively these data represent an important step towards a metrologically traceable calibration of 40K concentrations in primary 40Ar/39Ar mineral standards and improve uncertainties by ca. an order of magnitude in the potassium isotopic compositions of standards.

  15. Relationship between colorimetric (instrumental) evaluation and consumer-defined beef colour acceptability.

    PubMed

    Holman, Benjamin W B; Mao, Yanwei; Coombs, Cassius E O; van de Ven, Remy J; Hopkins, David L

    2016-11-01

    The relationship between instrumental colorimetric values (L*, a*, b*, the ratio of reflectance at 630nm and 580nm) and consumer perception of acceptable beef colour was evaluated using a web-based survey and standardised photographs of beef m. longissimus lumborum with known colorimetrics. Only L* and b* were found to relate to average consumer opinions of beef colour acceptability. Respondent nationality was also identified as a source of variation in beef colour acceptability score. Although this is a preliminary study with the findings necessitating additional investigation, these results suggest L* and b* as candidates for developing instrumental thresholds for consumer beef colour expectations. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  16. Correlation of laser velocimeter measurements over a wing with results of two prediction techniques. [in the Langley V/STOL tunnel

    NASA Technical Reports Server (NTRS)

    Hoad, D. R.; Meyers, J. F.; Young, W. H., Jr.; Hepner, T. P.

    1978-01-01

    The flow field at the center line of an unswept wing with an aspect ratio of eight was determined using a two dimensional viscous flow prediction technique for the flow field calculation, and a three dimensional potential flow panel method to evaluate the degree of two dimensionality achieved at the wing center line. The analysis was made to provide an acceptable reference for comparison with velocity measurements obtained from a fringe type laser velocimeter optics systems operating in the backscatter mode in the Langley V/STOL tunnel. Good agreement between laser velocimeter measurements and theoretical results indicate that both methods provide a true representation of the velocity field about the wing at angles of attack of 0.6 and 4.75 deg.

  17. Compression techniques in tele-radiology

    NASA Astrophysics Data System (ADS)

    Lu, Tianyu; Xiong, Zixiang; Yun, David Y.

    1999-10-01

    This paper describes a prototype telemedicine system for remote 3D radiation treatment planning. Due to voluminous medical image data and image streams generated in interactive frame rate involved in the application, the importance of deploying adjustable lossy to lossless compression techniques is emphasized in order to achieve acceptable performance via various kinds of communication networks. In particular, the compression of the data substantially reduces the transmission time and therefore allows large-scale radiation distribution simulation and interactive volume visualization using remote supercomputing resources in a timely fashion. The compression algorithms currently used in the software we developed are JPEG and H.263 lossy methods and Lempel-Ziv (LZ77) lossless methods. Both objective and subjective assessment of the effect of lossy compression methods on the volume data are conducted. Favorable results are obtained showing that substantial compression ratio is achievable within distortion tolerance. From our experience, we conclude that 30dB (PSNR) is about the lower bound to achieve acceptable quality when applying lossy compression to anatomy volume data (e.g. CT). For computer simulated data, much higher PSNR (up to 100dB) is expectable. This work not only introduces such novel approach for delivering medical services that will have significant impact on the existing cooperative image-based services, but also provides a platform for the physicians to assess the effects of lossy compression techniques on the diagnostic and aesthetic appearance of medical imaging.

  18. Determinants of Mobile Learning Acceptance: An Empirical Investigation in Higher Education

    ERIC Educational Resources Information Center

    Akour, Hassan

    2010-01-01

    Scope and method of study: The purpose of this study was to investigate the determinants of mobile learning acceptance in higher education. Mobile learning is a rapidly growing method of learning that utilizes mobile devices to deliver content. Acceptance of mobile learning theory was derived from technology acceptance theories. The study…

  19. Measurement of solar extinction in tower plants with digital cameras

    NASA Astrophysics Data System (ADS)

    Ballestrín, J.; Monterreal, R.; Carra, M. E.; Fernandez-Reche, J.; Barbero, J.; Marzo, A.

    2016-05-01

    Atmospheric extinction of solar radiation between the heliostat field and the receiver is accepted as a non-negligible source of energy loss in the increasingly large central receiver plants. However, the reality is that there is currently no reliable measurement method for this quantity and at present these plants are designed, built and operated without knowing this local parameter. Nowadays digital cameras are used in many scientific applications for their ability to convert available light into digital images. Its broad spectral range, high resolution and high signal to noise ratio, make them an interesting device in solar technology. In this work a method for atmospheric extinction measurement based on digital images is presented. The possibility of defining a measurement setup in circumstances similar to those of a tower plant increases the credibility of the method. This procedure is currently being implemented at Plataforma Solar de Almería.

  20. Simulation of rare events in quantum error correction

    NASA Astrophysics Data System (ADS)

    Bravyi, Sergey; Vargo, Alexander

    2013-12-01

    We consider the problem of calculating the logical error probability for a stabilizer quantum code subject to random Pauli errors. To access the regime of large code distances where logical errors are extremely unlikely we adopt the splitting method widely used in Monte Carlo simulations of rare events and Bennett's acceptance ratio method for estimating the free energy difference between two canonical ensembles. To illustrate the power of these methods in the context of error correction, we calculate the logical error probability PL for the two-dimensional surface code on a square lattice with a pair of holes for all code distances d≤20 and all error rates p below the fault-tolerance threshold. Our numerical results confirm the expected exponential decay PL˜exp[-α(p)d] and provide a simple fitting formula for the decay rate α(p). Both noiseless and noisy syndrome readout circuits are considered.

  1. Objective criteria for acceptability and constancy tests of digital subtraction angiography.

    PubMed

    de las Heras, Hugo; Torres, Ricardo; Fernández-Soto, José Miguel; Vañó, Eliseo

    2016-01-01

    Demonstrate an objective procedure to quantify image quality in digital subtraction angiography (DSA) and suggest thresholds for acceptability and constancy tests. Series of images were obtained in a DSA system simulating a small (paediatric) and a large patient using the dynamic phantom described in the IEC and DIN standards for acceptance tests of DSA equipment. Image quality was quantified using measurements of contrast-to-noise ratio (CNR). Overall scores combining the CNR of 10-100 mg/ml Iodine at a vascular diameter of 1-4 mm in a homogeneous background were defined. Phantom entrance surface air kerma (Ka,e) was measured with an ionisation chamber. The visibility of a low-contrast vessel in DSA images has been identified with a CNR value of 0.50 ± 0.03. Despite using 14 times more Ka,e (8.85 vs 0.63 mGy/image), the protocol for large patients showed a decrease in the overall score CNRsum of 67% (4.21 ± 0.06 vs 2.10 ± 0.05). The uncertainty in the results of the objective method was below 5%. Objective evaluation of DSA images using CNR is feasible with dedicated phantom measurements. An objective methodology has been suggested for acceptance tests compliant with the IEC/DIN standards. The defined overall scores can serve to fix a reproducible baseline for constancy tests, as well as to study the device stability within one acquisition series and compare different imaging protocols. This work provides aspects that have not been included in the recent European guidelines on Criteria for Acceptability of Medical Radiological Equipment. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Risk-adjusted clinical outcomes in patients enrolled in a bloodless program

    PubMed Central

    Frank, Steven M.; Wick, Elizabeth C.; Dezern, Amy E.; Ness, Paul M.; Wasey, Jack O.; Pippa, Andrew C.; Dackiw, Elizabeth; Resar, Linda M.S.

    2014-01-01

    BACKGROUND Although clinical outcomes have been reported for patients who do not accept allogeneic blood transfusion (ABT), many previous studies lack a control group, fail to use risk adjustment, and focus exclusively on cardiac surgery. STUDY DESIGN AND METHODS We report a risk-adjusted, propensity score–matched, retrospective case-control study of clinical outcomes for inpatients who did not accept ABT (bloodless, n = 294) and those who did accept ABT (control, n = 1157). Multidisciplinary specialized care was rendered to the bloodless patients to conserve blood and optimize clinical outcomes. Differences in hemoglobin (Hb), mortality, five morbid outcomes, and hospital charges and costs were compared. Subgroups of medical and surgical patients were analyzed, and independent predictors of outcome were determined by multivariate analysis. RESULTS Overall, mortality was lower in the bloodless group (0.7%) than in the control group (2.7%; p = 0.046), primarily attributed to the surgical subgroup. After risk adjustment, bloodless care was not an independent predictor of the composite adverse outcome (death or any morbid event; p = 0.91; odds ratio, 1.02; 95% confidence interval, 0.68–1.53). Discharge Hb concentrations were similar in the bloodless (10.8 ± 2.7 g/dL) and control (10.9 ± 2.3 g/dL) groups (p = 0.42). Total and direct hospital costs were 12% (p = 0.02) and 18% (p = 0.02) less, respectively, in the bloodless patients, a difference attributed to the surgical subgroup. CONCLUSIONS Using appropriate blood conservation measures for patients who do not accept ABT results in similar or better outcomes and is associated with equivalent or lower costs. This specialized care may be beneficial even for those patients who accept ABT. PMID:24942198

  3. Willingness to pay per quality-adjusted life year: is one threshold enough for decision-making?: results from a study in patients with chronic prostatitis.

    PubMed

    Zhao, Fei-Li; Yue, Ming; Yang, Hua; Wang, Tian; Wu, Jiu-Hong; Li, Shu-Chuen

    2011-03-01

    To estimate the willingness to pay (WTP) per quality-adjusted life year (QALY) ratio with the stated preference data and compare the results obtained between chronic prostatitis (CP) patients and general population (GP). WTP per QALY was calculated with the subjects' own health-related utility and the WTP value. Two widely used preference-based health-related quality of life instruments, EuroQol (EQ-5D) and Short Form 6D (SF-6D), were used to elicit utility for participants' own health. The monthly WTP values for moving from participants' current health to a perfect health were elicited using closed-ended iterative bidding contingent valuation method. A total of 268 CP patients and 364 participants from GP completed the questionnaire. We obtained 4 WTP/QALY ratios ranging from $4700 to $7400, which is close to the lower bound of local gross domestic product per capita, a threshold proposed by World Health Organization. Nevertheless, these values were lower than other proposed thresholds and published empirical researches on diseases with mortality risk. Furthermore, the WTP/QALY ratios from the GP were significantly lower than those from the CP patients, and different determinants were associated with the within group variation identified by multiple linear regression. Preference elicitation methods are acceptable and feasible in the socio-cultural context of an Asian environment and the calculation of WTP/QALY ratio produced meaningful answers. The necessity of considering the QALY type or disease-specific QALY in estimating WTP/QALY ratio was highlighted and 1 to 3 times of gross domestic product/capita recommended by World Health Organization could potentially serve as a benchmark for threshold in this Asian context.

  4. Comparison of manual and homogenizer methods for preparation of tick-derived stabilates of Theileria parva: equivalence testing using an in vitro titration model.

    PubMed

    Mbao, V; Speybroeck, N; Berkvens, D; Dolan, T; Dorny, P; Madder, M; Mulumba, M; Duchateau, L; Brandt, J; Marcotty, T

    2005-07-01

    Theileria parva sporozoite stabilates are used in the infection and treatment method of immunization, a widely accepted control option for East Coast fever in cattle. T. parva sporozoites are extracted from infected adult Rhipicephalus appendiculatus ticks either manually, using a pestle and a mortar, or by use of an electric homogenizer. A comparison of the two methods as a function of stabilate infectivity has never been documented. This study was designed to provide a quantitative comparison of stabilates produced by the two methods. The approach was to prepare batches of stabilate by both methods and then subject them to in vitro titration. Equivalence testing was then performed on the average effective doses (ED). The ratio of infective sporozoites yielded by the two methods was found to be 1.14 in favour of the manually ground stabilate with an upper limit of the 95% confidence interval equal to 1.3. We conclude that the choice of method rests more on costs, available infrastructure and standardization than on which method produces a richer sporozoite stabilate.

  5. Hamilton-Jacobi formalism to warm inflationary scenario

    NASA Astrophysics Data System (ADS)

    Sayar, K.; Mohammadi, A.; Akhtari, L.; Saaidi, Kh.

    2017-01-01

    The Hamilton-Jacobi formalism as a powerful method is being utilized to reconsider the warm inflationary scenario, where the scalar field as the main component driving inflation interacts with other fields. Separating the context into strong and weak dissipative regimes, the goal is followed for two popular functions of Γ . Applying slow-rolling approximation, the required perturbation parameters are extracted and, by comparing to the latest Planck data, the free parameters are restricted. The possibility of producing an acceptable inflation is studied where the result shows that for all cases the model could successfully suggest the amplitude of scalar perturbation, scalar spectral index, its running, and the tensor-to-scalar ratio.

  6. Evolving Concepts on Adjusting Human Resting Energy Expenditure Measurements for Body Size

    PubMed Central

    Heymsfield, Steven B.; Thomas, Diana; Bosy-Westphal, Anja; Shen, Wei; Peterson, Courtney M.; Müller, Manfred J.

    2012-01-01

    Establishing if an adult’s resting energy expenditure (REE) is high or low for their body size is a pervasive question in nutrition research. Early workers applied body mass and height as size measures and formulated the Surface Law and Kleiber’s Law, although each has limitations when adjusting REE. Body composition methods introduced during the mid-twentieth century provided a new opportunity to identify metabolically homogeneous “active” compartments. These compartments all show improved correlations with REE estimates over body mass-height approaches, but collectively share a common limitation: REE-body composition ratios are not “constant” but vary across men and women and with race, age, and body size. The now-accepted alternative to ratio-based norms is to adjust for predictors by applying regression models to calculate “residuals” that establish if a REE is relatively high or low. The distinguishing feature of statistical REE-body composition models is a “non-zero” intercept of unknown origin. The recent introduction of imaging methods has allowed development of physiological tissue-organ based REE prediction models. Herein we apply these imaging methods to provide a mechanistic explanation, supported by experimental data, for the non-zero intercept phenomenon and in that context propose future research directions for establishing between subject differences in relative energy metabolism. PMID:22863371

  7. Accuracy of pedicle screw placement comparing robot-assisted technology and the free-hand with fluoroscopy-guided method in spine surgery: An updated meta-analysis.

    PubMed

    Fan, Yong; Du, Jin Peng; Liu, Ji Jun; Zhang, Jia Nan; Qiao, Huan Huan; Liu, Shi Chang; Hao, Ding Jun

    2018-06-01

    A miniature spine-mounted robot has recently been introduced to further improve the accuracy of pedicle screw placement in spine surgery. However, the differences in accuracy between the robotic-assisted (RA) technique and the free-hand with fluoroscopy-guided (FH) method for pedicle screw placement are controversial. A meta-analysis was conducted to focus on this problem. Several randomized controlled trials (RCTs) and cohort studies involving RA and FH and published before January 2017 were searched for using the Cochrane Library, Ovid, Web of Science, PubMed, and EMBASE databases. A total of 55 papers were selected. After the full-text assessment, 45 clinical trials were excluded. The final meta-analysis included 10 articles. The accuracy of pedicle screw placement within the RA group was significantly greater than the accuracy within the FH group (odds ratio 95%, "perfect accuracy" confidence interval: 1.38-2.07, P < .01; odds ratio 95% "clinically acceptable" Confidence Interval: 1.17-2.08, P < .01). There are significant differences in accuracy between RA surgery and FH surgery. It was demonstrated that the RA technique is superior to the conventional method in terms of the accuracy of pedicle screw placement.

  8. A critical assessment of the performance criteria in confirmatory analysis for veterinary drug residue analysis using mass spectrometric detection in selected reaction monitoring mode.

    PubMed

    Berendsen, Bjorn J A; Meijer, Thijs; Wegh, Robin; Mol, Hans G J; Smyth, Wesley G; Armstrong Hewitt, S; van Ginkel, Leen; Nielen, Michel W F

    2016-05-01

    Besides the identification point system to assure adequate set-up of instrumentation, European Commission Decision 2002/657/EC includes performance criteria regarding relative ion abundances in mass spectrometry and chromatographic retention time. In confirmatory analysis, the relative abundance of two product ions, acquired in selected reaction monitoring mode, the ion ratio should be within certain ranges for confirmation of the identity of a substance. The acceptable tolerance of the ion ratio varies with the relative abundance of the two product ions and for retention time, CD 2002/657/EC allows a tolerance of 5%. Because of rapid technical advances in analytical instruments and new approaches applied in the field of contaminant testing in food products (multi-compound and multi-class methods) a critical assessment of these criteria is justified. In this study a large number of representative, though challenging sample extracts were prepared, including muscle, urine, milk and liver, spiked with 100 registered and banned veterinary drugs at levels ranging from 0.5 to 100 µg/kg. These extracts were analysed using SRM mode using different chromatographic conditions and mass spectrometers from different vendors. In the initial study, robust data was collected using four different instrumental set-ups. Based on a unique and highly relevant data set, consisting of over 39 000 data points, the ion ratio and retention time criteria for applicability in confirmatory analysis were assessed. The outcomes were verified based on a collaborative trial including laboratories from all over the world. It was concluded that the ion ratio deviation is not related to the value of the ion ratio, but rather to the intensity of the lowest product ion. Therefore a fixed ion ratio deviation tolerance of 50% (relative) is proposed, which also is applicable for compounds present at sub-ppb levels or having poor ionisation efficiency. Furthermore, it was observed that retention time shifts, when using gradient elution, as is common practice nowadays, are mainly observed for early eluting compounds. Therefore a maximum retention time deviation of 0.2 min (absolute) is proposed. These findings should serve as input for discussions on the revision of currently applied criteria and the establishment of a new, globally accepted, criterion document for confirmatory analysis. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Prognostic Value of Thyroid Hormone Levels in Patients Evaluated for Liver Transplantation

    PubMed Central

    Van Thiel, David H.; Udani, Mahendra; Schade, Robert R.; Sanghvi, Agit; Starzl, Thomas E.

    2010-01-01

    The thyroid hormones T4, T3, rT3 and TSH were assayed in 134 adult patients evaluated and accepted as potential liver transplant candidates at the University of Pittsburgh from March, 1981 to December, 1983. The subsequent course of these patients was evaluated with respect to the levels of these hormones obtained at the time of acceptance for transplantation. T4 levels were increased significantly while their T3 levels were reduced (both p < 0.01) in those who survived and were discharged home as compared to either those who died waiting to be transplanted or died following the procedure. As a result, the ratio of T3/T4 was reduced markedly (p < 0.01) in those who were transplanted and survived as compared to those not transplanted or dying following transplantation. Importantly, the rT3 levels clearly separated (p < 0.01) those who would die prior to transplantation from those who would survive to be transplanted. Finally, the ratio rT3/T3 even more clearly separates those who will die prior to transplantation (p < 0.01) from the other two groups. These data suggest that thyroid hormone levels, particularly rT3 levels, might be useful in setting priorities for which patients referred for a transplantation evaluation should be accepted into the program and in determining who among accepted patients should be operated upon in preference to others also accepted and waiting to be transplanted. PMID:2993148

  10. An approach to optimize the batch mixing process for improving the quality consistency of the products made from traditional Chinese medicines*

    PubMed Central

    Yan, Bin-jun; Qu, Hai-bin

    2013-01-01

    The efficacy of traditional Chinese medicine (TCM) is based on the combined effects of its constituents. Variation in chemical composition between batches of TCM has always been the deterring factor in achieving consistency in efficacy. The batch mixing process can significantly reduce the batch-to-batch quality variation in TCM extracts by mixing them in a well-designed proportion. However, reducing the quality variation without sacrificing too much of the production efficiency is one of the challenges. Accordingly, an innovative and practical batch mixing method aimed at providing acceptable efficiency for industrial production of TCM products is proposed in this work, which uses a minimum number of batches of extracts to meet the content limits. The important factors affecting the utilization ratio of the extracts (URE) were studied by simulations. The results have shown that URE was affected by the correlation between the contents of constituents, and URE decreased with the increase in the number of targets and the relative standard deviations of the contents. URE could be increased by increasing the number of storage tanks. The results have provided a reference for designing the batch mixing process. The proposed method has possible application value in reducing the quality variation in TCM and providing acceptable production efficiency simultaneously. PMID:24190450

  11. An approach to optimize the batch mixing process for improving the quality consistency of the products made from traditional Chinese medicines.

    PubMed

    Yan, Bin-jun; Qu, Hai-bin

    2013-11-01

    The efficacy of traditional Chinese medicine (TCM) is based on the combined effects of its constituents. Variation in chemical composition between batches of TCM has always been the deterring factor in achieving consistency in efficacy. The batch mixing process can significantly reduce the batch-to-batch quality variation in TCM extracts by mixing them in a well-designed proportion. However, reducing the quality variation without sacrificing too much of the production efficiency is one of the challenges. Accordingly, an innovative and practical batch mixing method aimed at providing acceptable efficiency for industrial production of TCM products is proposed in this work, which uses a minimum number of batches of extracts to meet the content limits. The important factors affecting the utilization ratio of the extracts (URE) were studied by simulations. The results have shown that URE was affected by the correlation between the contents of constituents, and URE decreased with the increase in the number of targets and the relative standard deviations of the contents. URE could be increased by increasing the number of storage tanks. The results have provided a reference for designing the batch mixing process. The proposed method has possible application value in reducing the quality variation in TCM and providing acceptable production efficiency simultaneously.

  12. Design, formulation and evaluation of green tea chewing gum

    PubMed Central

    Aslani, Abolfazl; Ghannadi, Alireza; Khalafi, Zeinab

    2014-01-01

    Background: The main purpose of this study is to design, formulate and evaluate the green tea gums with a suitable taste and quality in order to produce an anti-oxidant chewing gum. Materials and Methods: Fresh green tea leaves obtained from Northern Iran for extraction. Maceration is the extraction method that is used in this study. The contents of caffeine, catechin and flavonoids of the hydro alcoholic extract were measured. Various formulations of the 120 mg green tea extract chewing gums with different sweeteners, flavoring agents and various gum bases were prepared afterward release pattern, content uniformity, organoleptic results and other properties were characterized. Results: The contents of caffeine, catechin and flavonoid of the hydro alcoholic extraction were 207.32 mg/g, 130.00 mg/g and 200.82 mg/g, respectively. Release pattern of green tea chewing gum with different gum base ratios and various sweeteners in phosphate buffer were prepared. A total of 60 persons who were 20-30 years of age, participated in our panel test for organoleptic properties such as taste, stiffness, stickiness, etc., Acceptable gum was the one with the same ratio of the used rubber bases. Cinnamon selected as the preferred taste by volunteers. Combination of aspartame, sugar and maltitol has appropriate taste. The effect of various sweetener on release pattern was negligible, on the other hand rubber bases ratio variation, changed the release pattern obviously. Conclusion: The green tea chewing gum with sugar, maltitol and aspartame sweeteners and cinnamon flavor, using the same rubber bases ratio may be a desirable antioxidant product. PMID:25161989

  13. The clinical significance of neutrophil-to-lymphocyte ratio and monocyte-to-lymphocyte ratio in Guillain-Barré syndrome.

    PubMed

    Huang, Yuanyuan; Ying, Zhaojian; Quan, Weiwei; Xiang, Weiwei; Xie, Dewei; Weng, Yiyun; Li, Xiang; Li, Jia; Zhang, Xu

    2018-08-01

    Purpose/Aim of the study: Guillain Barré syndrome (GBS) is a severe peripheral nervous disease that leads to muscle weakness and areflexia. We now commonly accept a synthesis that inflammation and immunity play key role in GBS pathogenesis. Many studies pointed out that neutrophil-to-lymphocyte ratio (NLR) and monocyte-to-lymphocyte ratio (MLR) are novel promising markers of inflammation or immunity. Our study aimed to evaluate whether the NLR and the MLR were associated to GBS or not. We measured blood cell count in 334 individuals including 117 GBS and 217 healthy controls. Our findings demonstrated that the GBS patients had higher levels of NLR and MLR than the healthy controls. The severe group also had higher levels of NLR and MLR compared to the mild group. We took the method of receiver-operating characteristic curve to find out the cut-off value of NLR for GBS occurrence and severity; it was 2.295 and 3.05, respectively. The cut-off values of MLR for GBS incidence and severity were the same, it was 0.235. In the setting of GBS, the NLR and MLR were significantly increased and they may be pathophysiologically and clinically relevant in GBS. The NLR and MLR would be new biomarkers of medical application.

  14. Application of Bayes' theorem for pulse shape discrimination

    NASA Astrophysics Data System (ADS)

    Monterial, Mateusz; Marleau, Peter; Clarke, Shaun; Pozzi, Sara

    2015-09-01

    A Bayesian approach is proposed for pulse shape discrimination of photons and neutrons in liquid organic scinitillators. Instead of drawing a decision boundary, each pulse is assigned a photon or neutron confidence probability. This allows for photon and neutron classification on an event-by-event basis. The sum of those confidence probabilities is used to estimate the number of photon and neutron instances in the data. An iterative scheme, similar to an expectation-maximization algorithm for Gaussian mixtures, is used to infer the ratio of photons-to-neutrons in each measurement. Therefore, the probability space adapts to data with varying photon-to-neutron ratios. A time-correlated measurement of Am-Be and separate measurements of 137Cs, 60Co and 232Th photon sources were used to construct libraries of neutrons and photons. These libraries were then used to produce synthetic data sets with varying ratios of photons-to-neutrons. Probability weighted method that we implemented was found to maintain neutron acceptance rate of up to 90% up to photon-to-neutron ratio of 2000, and performed 9% better than the decision boundary approach. Furthermore, the iterative approach appropriately changed the probability space with an increasing number of photons which kept the neutron population estimate from unrealistically increasing.

  15. Application of Bayes' theorem for pulse shape discrimination

    DOE PAGES

    Marleau, Peter; Monterial, Mateusz; Clarke, Shaun; ...

    2015-06-14

    A Bayesian approach is proposed for pulse shape discrimination of photons and neutrons in liquid organic scinitillators. Instead of drawing a decision boundary, each pulse is assigned a photon or neutron confidence probability. In addition, this allows for photon and neutron classification on an event-by-event basis. The sum of those confidence probabilities is used to estimate the number of photon and neutron instances in the data. An iterative scheme, similar to an expectation-maximization algorithm for Gaussian mixtures, is used to infer the ratio of photons-to-neutrons in each measurement. Therefore, the probability space adapts to data with varying photon-to-neutron ratios. Amore » time-correlated measurement of Am–Be and separate measurements of 137Cs, 60Co and 232Th photon sources were used to construct libraries of neutrons and photons. These libraries were then used to produce synthetic data sets with varying ratios of photons-to-neutrons. Probability weighted method that we implemented was found to maintain neutron acceptance rate of up to 90% up to photon-to-neutron ratio of 2000, and performed 9% better than the decision boundary approach. Furthermore, the iterative approach appropriately changed the probability space with an increasing number of photons which kept the neutron population estimate from unrealistically increasing.« less

  16. Lead isotope ratios for bullets, forensic evaluation in a Bayesian paradigm.

    PubMed

    Sjåstad, Knut-Endre; Lucy, David; Andersen, Tom

    2016-01-01

    Forensic science is a discipline concerned with collection, examination and evaluation of physical evidence related to criminal cases. The results from the activities of the forensic scientist may ultimately be presented to the court in such a way that the triers of fact understand the implications of the data. Forensic science has been, and still is, driven by development of new technology, and in the last two decades evaluation of evidence based on logical reasoning and Bayesian statistic has reached some level of general acceptance within the forensic community. Tracing of lead fragments of unknown origin to a given source of ammunition is a task that might be of interest for the Court. Use of data from lead isotope ratios analysis interpreted within a Bayesian framework has shown to be suitable method to guide the Court to draw their conclusion for such task. In this work we have used isotopic composition of lead from small arms projectiles (cal. .22) and developed an approach based on Bayesian statistics and likelihood ratio calculation. The likelihood ratio is a single quantity that provides a measure of the value of evidence that can be used in the deliberation of the court. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Acceptability of Ecological Momentary Assessment among Young Men Who Have Sex with Men

    ERIC Educational Resources Information Center

    Duncan, Dustin T.; Kapadia, Farzana; Kirchner, Thomas R.; Goedel, William C.; Brady, William J.; Halkitis, Perry N.

    2017-01-01

    The study evaluated the acceptability of text message- and voice-based ecological momentary assessment (EMA) methods among a sample (N = 74) of young men who have sex with men (MSM). We assessed the acceptability of text message- and voice-based EMA methods. Almost all participants (96%) reported that they would be willing to accept texts on their…

  18. USE OF DIAGNODENT® FOR DIAGNOSIS OF NON-CAVITATED OCCLUSALDENTIN CARIES

    PubMed Central

    Costa, Ana Maria; de Paula, Lilian Marly; Bezerra, Ana Cristina Barreto

    2008-01-01

    The purpose of this study was to evaluate the use of a laser fluorescence device for detection of occlusal caries in permanent teeth. One hundred and ninety-nine non-cavitated teeth from 26 patients aged 10 to 13 years were selected. After dental prophylaxis, two previously calibrated dentists examined the teeth. Visual inspection, radiographic examination and laser measurements were performed under standardized conditions. The validation method was cavity preparation with a small cone-shaped diamond bur, when the two examiners agreed about the presence of dentin caries. It was found that the laser detection method produced high values of sensitivity (0.93) and specificity (0.75) and a moderate positive predictive value (0.63). The laser device showed the lowest value of likelihood ratio (3.68). Kappa coefficient showed good repeatability for all methods. Although the laser device had an acceptable performance, this equipment should be used as an adjunct method to visual inspection to avoid false positive results. PMID:19089284

  19. Rapid and simultaneous determination of Strontium-89 and Strontium-90 in seawater.

    PubMed

    Tayeb, Michelle; Dai, Xiongxin; Sdraulig, Sandra

    2016-03-01

    A rapid method has been developed for the direct determination of radiostrontium ((89)Sr and (90)Sr) released in seawater in the early phase of an accident. The method employs a fast and effective pre-concentration of radiostrontium by Sr-Ca co-precipitation followed by separation of radiostrontium using extraction chromatography technique. Radiostrontium is effectively separated in the presence of excessive dominant salts of seawater. Čerenkov and liquid scintillation assay (LSA) techniques are used to determine (89)Sr and (90)Sr. Sample preparation time is approximately 4 h for a set of 10 samples. The method was validated using spiked seawater samples at various activity ratios of (89)Sr:(90)Sr ranging from 1:10 to 9:1. The mean chemical recovery of Sr was 85 ± 3%. (90)Sr showed variable relative bias which enhanced with increasing ratio of (89)Sr:(90)Sr and was in the range ± 21%. The highest biases of (90)Sr determination were due to lower activity concentrations of (90)Sr and are regarded as acceptable in emergency situations with elevated levels of radiostrontium in the sample. The minimum detectable concentration (MDC) of (90)Sr and (89)Sr varied at different (89)Sr:(90)Sr ratios. For 0.1 L seawater and 15 min counting time on a low background Hidex liquid scintillation counter (LSC), the MDC of (90)Sr was in the range of 1.7-3.5 Bq L(-1) and MDC of (89)Sr was in the range 0.5-2.4 Bq L(-1). Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Short communication: Semiquantitative assessment of 99mTc-EDDA/HYNIC-TOC scintigraphy in differentiation of solitary pulmonary nodules--a complementary role to visual analysis.

    PubMed

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-02-01

    The aim of this study was the assessment of a value of a semiquantitative analysis of scintigrams obtained with (99m)Tc-EDDA/HYNIC-TOC as a radiopharmaceutical (RPH) in differential diagnosis of solitary pulmonary nodules (SPNs), as a method complementary to visual evaluation of scintigrams. Scintigraphic images of 59 patients (33 males and 26 females between 34 and 78 years of age, mean value, 57) with SPN on chest radiographs (39 malignant and 20 benign) were retrospectively assessed semiquantitatively. Visual scintigram analysis was made earlier, prospectively. Nodule diameters ranged from 1 to 4 (mean 2.2) cm. A single photon emission computed tomography (SPECT) acquisition was performed at 2-4 hours after administration of 740 to 925 MBq of a RPH. Verification of scintigraphic results was based on a pathological examination of tumor samples (histopathology or cytology) and, in some cases, on bacteriological studies. As an additional criterion for tumor benignity, its stable size in a time interval not shorter than 3 years was accepted. A simple, semiquantitative method for assessment of radiopharmaceutical uptake in SPNs was used, based on "count sample" taken from tumor center (T) in relation to radiopharmaceutical concentration in the background (B) measured in the contralateral lung. A criterion for optimal differentiation between malignant and benign nodules (T/B ratio threshold value) was introduced, based on a receiver operating characteristic (ROC) curve. Additionally, a value of T/B ratio was searched for, excluding tumor benignity with high probability. Visual analysis of scintigrams revealed enhanced uptake of RPH at 36 of 39 (92%) sites, corresponding to locations of malignant nodules (including 34 of 35-97% cases of lung cancer). In 13 of 20 (65%) benign nodules, true negative results were obtained. Accuracy of the method equalled 83%. Optimal differentiation between malignant and benign nodules was found for a value of a T/B ratio amounting to 2. The semiquantitative method gave true positive results in 35 of 39 (90%) malignant nodules (as in visual method in 34 of 35-97% cases of lung cancer). True negative results were obtained in 17 of 20 (85%) benign cases. Accuracy of the method reached 88%. A T/B ratio exceeding 4 excluded tumor benignity with high probability. A simple method, of quantitatively assessing 99mTc-EDDA/HYNICTOC uptake in solitary pulmonary nodules by means of a T/B ratio can play a role that is complementary to the visual evaluation of scintigrams. It improves low specificity of the method in the detection of malignant nodules, without significant reduction of its sensitivity and provides a T/B ratio excluding tumor benignity with high probability.

  1. Validating urinary measurement of beta-2-microglobulin with a Roche reagent kit designed for serum measurements.

    PubMed

    Chan, Pak Cheung R; Kulasingam, Vathany; Lem-Ragosnig, Bonny

    2012-11-01

    To validate the use of a Roche serum beta-2-microglobulin (B2MG) kit for urinary B2MG measurements, and to establish reference limits for urinary B2MG/creatinine ratio from healthy individuals. The Roche B2MG Tina-Quant serum kit was used to measure urinary B2MG immunoturbidimetrically. Using human urine as a diluent, the B2MG method was linear from 73-2156 μg/L. The imprecision on a commercially available urine QC was 4.4% at a concentration of 380 μg/L. Limit of quantification at <20% CV was 40 μg/L. Method comparison with Immulite 2000 (Siemens) yielded slope=1.180 (95% CI 1.14-1.22), intercept=11.5 (95% CI -3.6-26.6), SEE=27.6 and r=0.99 (n=26) by the Deming regression analysis. The upper reference limit of B2MG/creatinine ratio determined from 195 healthy adults was 29 μg/mmol (97.5th centile). The serum B2MG Tina Quant reagent kit is acceptable to measure urinary B2MG. Copyright © 2012. Published by Elsevier Inc.

  2. Measurement of body fat and hydration of the fat-free body in health and disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Streat, S.J.; Beddoe, A.H.; Hill, G.L.

    1985-06-01

    Body fat mass, fat-free body mass and body water are basic components of body composition which are used in nutritional and metabolic studies and in patient care. A method of measuring total body fat (TBF), fat-free mass (FFM) and its hydration (TBW/FFM) involving prompt gamma in vivo neutron activation analysis (IVNAA) and tritium dilution has been compared with the more traditional methods of densitometry and skinfold anthropometry in 36 normal volunteers, and with skinfold anthropometry in 56 patients presenting for nutritional support. While the mean values of TBF were in reasonable agreement for the three methods in normals it wasmore » founds that skinfold anthropometry underestimated TBF relative to the IVNAA/tritium method by, on average, 3.0 kg (19%) in patients. Furthermore, the ranges of values in normals of the ratio TBW/FFM for the anthropometric (0.62 to 0.80) and densitometric (0.65 to 0.80) methods were much wider than the range for the IVNAA/tritium method (0.69 to 0.76), in which TBW was measured by tritium dilution in all cases. In the patients, the ranges of this ratio were 0.52 to 0.90 for the anthropometric method and 0.67 to 0.82 for the IVNAA/tritium method; clearly anthropometry yields values of TBW/FFM which are outside accepted biological limits. On the basis of these findings, ranges of TBW/FFM are suggested for both normal adults (0.69 to 0.75) and patients requiring nutritional support (0.67 to 0.83). Finally it is concluded that the IVNAA/tritium method is a suitable method for measuring TBF and FFM and particularly so when body composition is abnormal.« less

  3. Wide acceptance angle, high concentration ratio, optical collector

    NASA Technical Reports Server (NTRS)

    Kruer, Mark Arthur (Inventor)

    1990-01-01

    The invention is directed to an optical collector requiring a wide acceptance angle, and a high concentration ratio. The invention is particularly adapted for use in solar collectors of cassegrain design. The optical collector system includes a parabolic circular concave primary mirror and a hyperbolic circular convex secondary mirror. The primary mirror includes a circular hole located at its center wherein a solar collector is located. The mirrored surface of the secondary mirror has three distinct zones: a center circle, an on-axis annulus, and an off-axis section. The parabolic shape of the primary mirror is chosen so that the primary mirror reflects light entering the system on-axis onto the on-axis annulus. A substantial amount of light entering the system off-axis is reflected by the primary mirror onto either the off-axis section or onto the center circle. Subsequently, the off-axis sections reflect the off-axis light toward the solar collector. Thus, off-axis light is captured which would otherwise be lost to the system. The novelty of the system appears to lie in the configuration of the primary mirror which focuses off-axis light onto an annular portion of the secondary mirror to enable capture thereof. This feature results in wide acceptance angle and a high concentration ratio, and also compensates for the effects of non-specular reflection, and enables a cassegrain configuration to be used where such characteristics are required.

  4. An intervention delivered by text message to increase the acceptability of effective contraception among young women in Palestine: study protocol for a randomised controlled trial.

    PubMed

    McCarthy, Ona L; Wazwaz, Ola; Jado, Iman; Leurent, Baptiste; Edwards, Phil; Adada, Samia; Stavridis, Amina; Free, Caroline

    2017-10-03

    Unintended pregnancy can negatively impact women's lives and is associated with poorer health outcomes for women and children. Many women, particularly in low- and middle-income countries, continue to face obstacles in avoiding unintended pregnancy. In the State of Palestine, a survey conducted in 2006 estimated that 38% of pregnancies are unintended. In 2014, unmet need for contraception was highest among young women aged 20-24 years, at 15%. Mobile phones are increasingly being used to deliver health support. Once developed, interventions delivered by mobile phone are often cheaper to deliver than face-to-face support. The London School of Hygiene and Tropical Medicine and the Palestinian Family Planning and Protection Association have partnered to develop and evaluate a contraceptive behavioural intervention for young women in Palestine delivered by mobile phone. The intervention was developed guided by behavioural science and consists of short, mobile phone text messages that contain information about contraception and behaviour change methods delivered over 4 months. We will evaluate the intervention by conducting a randomised controlled trial. Five hundred and seventy women aged 18-24 years, who do not report using an effective method of contraception, will be allocated with a 1:1 ratio to receive the intervention text messages or control text messages about trial participation. The primary outcome is self-reported acceptability of at least one method of effective contraception at 4 months. Secondary outcomes include the use of effective contraception, acceptability of individual methods, discontinuation, service uptake, unintended pregnancy and abortion. Process outcomes include knowledge, perceived norms, personal agency and intervention dose received. Outcomes at 4 months will be compared between arms using logistic regression. This trial will determine the effect of the intervention on young women's attitudes towards the most effective methods of contraception. If the intervention is found to be effective, the intervention will be implemented widely across Palestine. The results could also be used to design a larger trial to establish its effect on unintended pregnancy. ClinicalTrials.gov, ID: NCT02905461 . Registered on 14 September 2016.

  5. Hydration Free Energy from Orthogonal Space Random Walk and Polarizable Force Field.

    PubMed

    Abella, Jayvee R; Cheng, Sara Y; Wang, Qiantao; Yang, Wei; Ren, Pengyu

    2014-07-08

    The orthogonal space random walk (OSRW) method has shown enhanced sampling efficiency in free energy calculations from previous studies. In this study, the implementation of OSRW in accordance with the polarizable AMOEBA force field in TINKER molecular modeling software package is discussed and subsequently applied to the hydration free energy calculation of 20 small organic molecules, among which 15 are positively charged and five are neutral. The calculated hydration free energies of these molecules are compared with the results obtained from the Bennett acceptance ratio method using the same force field, and overall an excellent agreement is obtained. The convergence and the efficiency of the OSRW are also discussed and compared with BAR. Combining enhanced sampling techniques such as OSRW with polarizable force fields is very promising for achieving both accuracy and efficiency in general free energy calculations.

  6. 46 CFR 164.023-11 - Acceptance tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... identification tests are conducted: (1) The average length/weight ratio of the thread in meters per kilogram... analysis, thermogravimetric analysis, differential scanning calorimeter, or other equivalent means adequate...

  7. Evaluation of Nurses' Acceptance of Screen Display Methods with Temporarily Non-Display for Privacy Protection.

    PubMed

    Niimi, Yukari; Ota, Katsumasa; Ikegami, Chikako

    2018-01-01

    The purpose of this study was to explore nurses' acceptance of a screen display method that temporarily hides patient information for privacy protection. Using a questionnaire, we asked nurses to evaluate the display method from the viewpoints of safety and efficiency with respect to 22 personal information items. The nurses were favorably interested in introducing the display method into their hospital system; however, their acceptance varied.

  8. Evaluation of teledermatology adoption by health-care professionals using a modified Technology Acceptance Model.

    PubMed

    Orruño, Estibalitz; Gagnon, Marie Pierre; Asua, José; Ben Abdeljelil, Anis

    2011-01-01

    We examined the main factors affecting the intention of physicians to use teledermatology using a modified Technology Acceptance Model (TAM). The investigation was carried out during a teledermatology pilot study conducted in Spain. A total of 276 questionnaires were sent to physicians by email and 171 responded (62%). Cronbach's alpha was acceptably high for all constructs. Theoretical variables were well correlated with each other and with the dependent variable (Intention to Use). Logistic regression indicated that the original TAM model was good at predicting physicians' intention to use teledermatology and that the variables Perceived Usefulness and Perceived Ease of Use were both significant (odds ratios of 8.4 and 7.4, respectively). When other theoretical variables were added, the model was still significant and it also became more powerful. However, the only significant predictor in the modified model was Facilitators with an odds ratio of 9.9. Thus the TAM was good at predicting physicians' intention to use teledermatology. However, the most important variable was the perception of Facilitators to using the technology (e.g. infrastructure, training and support).

  9. Peer Passenger Norms and Pressure: Experimental Effects on Simulated Driving Among Teenage Males

    PubMed Central

    Bingham, C. Raymond; Simons-Morton, Bruce G.; Pradhan, Anuj K.; Li, Kaigang; Almani, Farideh; Falk, Emily B.; Shope, Jean T.; Buckley, Lisa; Ouimet, Marie Claude; Albert, Paul S.

    2016-01-01

    Objective Serious crashes are more likely when teenage drivers have teenage passengers. One likely source of this increased risk is social influences on driving performance. This driving simulator study experimentally tested the effects of peer influence (i.e., risk-accepting compared to risk-averse peer norms reinforced by pressure) on the driving risk behavior (i.e., risky driving behavior and inattention to hazards) of male teenagers. It was hypothesized that peer presence would result in greater driving risk behavior (i.e., increased driving risk and reduced latent hazard anticipation), and that the effect would be greater when the peer was risk-accepting. Methods Fifty-three 16- and 17-year-old male participants holding a provisional U.S., State of Michigan driver license were randomized to either a risk-accepting or risk-averse condition. Each participant operated a driving simulator while alone and separately with a confederate peer passenger. The simulator world included scenarios designed to elicit variation in driving risk behavior with a teen passenger present in the vehicle. Results Significant interactions of passenger presence (passenger present vs. alone) by risk condition (risk-accepting vs. risk-averse) were observed for variables measuring: failure to stop at yellow light intersections (Incident Rate Ratio (IRR)=2.16; 95% Confidence Interval [95CI]=1.06, 4.43); higher probability of overtaking (IRR=10.17; 95CI=1.43, 73.35); shorter left turn latency (IRR=0.43; 95CI=0.31,0.60); and, failure to stop at an intersection with an occluded stop sign (IRR=7.90; 95CI=2.06,30.35). In all cases, greater risky driving by participants was more likely with a risk-accepting passenger versus a risk-averse passenger present and a risk-accepting passenger present versus driving alone. Conclusions Exposure of male teenagers to a risk-accepting confederate peer passenger who applied peer influence increased simulated risky driving behavior compared with exposure to a risk-averse confederate peer passenger or driving alone. These results are consistent with the contention that variability in teenage risky driving is in part explained by social influences. PMID:27818610

  10. Public acceptance of management methods under different human-wildlife conflict scenarios.

    PubMed

    Liordos, Vasilios; Kontsiotis, Vasileios J; Georgari, Marina; Baltzi, Kerasia; Baltzi, Ioanna

    2017-02-01

    Wildlife management seeks to minimise public controversy for successful application of wildlife control methods. Human dimensions research in wildlife seeks a better understanding of public preferences for effective human-wildlife conflict resolution. In face to face interviews, 630 adults in Greece were asked to rate on a 5-point Likert-like scale their acceptance of 3 management methods, i.e., do nothing, non-lethal control, and lethal control, in the context of 5 human-wildlife conflict scenarios: 1) corvids damage crops; 2) starlings damage crops; 3) starlings foul urban structures; 4) coypus damage crops; and 5) coypus transfer disease. Univariate GLMs determined occupation, hunting membership and their interaction as the stronger predictors of public acceptance, generating 4 stakeholder groups: the general public, farmers, hunters, and farmers-hunters. Differences in acceptance and consensus among stakeholder groups were assessed using the Potential for Conflict Index 2 (PCI 2 ). All 4 stakeholder groups agreed that doing nothing was unacceptable and non-lethal control acceptable in all 5 scenarios, with generally high consensus within and between groups. The lethal control method was more controversial and became increasingly more acceptable as the severity of scenarios was increased and between non-native and native species. Lethal control was unacceptable for the general public in all scenarios. Farmers accepted lethal methods in the corvids and starlings scenarios, were neutral in the coypus damage crops scenario, whereas they accepted lethal control when coypus transfer disease. Hunters' opinion was neutral in the corvids, starlings and coypus damage crops and starlings foul urban structures scenarios, but they accepted lethal methods in the coypus transfer disease scenario. Farmers-hunters considered lethal control acceptable in all 5 scenarios. Implications from this study could be used for designing a socio-ecological approach which incorporates wildlife management with public interests. The studied species have a wide distribution, therefore present findings might also prove useful elsewhere. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Evaluation of variability and quality control procedures for a receptor-binding assay for paralytic shellfish poisoning toxins.

    PubMed

    Ruberu, S R; Langlois, G W; Masuda, M; Perera, S Kusum

    2012-01-01

    The receptor-binding assay (RBA) method for determining saxatoxin (STX) and its numerous analogues, which cause paralytic shellfish poisoning (PSP) in humans, was evaluated in a single laboratory study. Each step of the assay preparation procedure including the performance of the multi-detector TopCount® instrument was evaluated for its contribution to method variability. The overall inherent RBA variability was determined to be 17%. Variability within the 12 detectors was observed; however, there was no reproducible pattern in detector performance. This observed variability among detectors could be attributed to other factors, such as pipetting errors. In an attempt to reduce the number of plates rejected due to excessive variability in the method's quality control parameters, a statistical approach was evaluated using either Grubbs' test or the Student's t-test for rejecting outliers in the measurement of triplicate wells. This approach improved the ratio of accepted versus rejected plates, saving cost and time for rerunning the assay. However, the potential reduction in accuracy and the lack of improvement in precision suggests caution when using this approach. The current study has recommended an alternate quality control procedure for accepting or rejecting plates in place of the criteria currently used in the published assay, or the alternative of outlier testing. The recommended procedure involves the development of control charts to monitor the critical parameters identified in the published method (QC sample, EC₅₀, slope of calibration curve), with the addition of a fourth critical parameter which is the top value (100% binding) of the calibration curve.

  12. Experimental investigation on performance and exhaust emissions of castor oil biodiesel from a diesel engine.

    PubMed

    Shojaeefard, M H; Etgahni, M M; Meisami, F; Barari, A

    2013-01-01

    Biodiesel, produced from plant and animal oils, is an important alternative to fossil fuels because, apart from dwindling supply, the latter are a major source of air pollution. In this investigation, effects of castor oil biodiesel blends have been examined on diesel engine performance and emissions. After producing castor methyl ester by the transesterification method and measuring its characteristics, the experiments were performed on a four cylinder, turbocharged, direct injection, diesel engine. Engine performance (power, torque, brake specific fuel consumption and thermal efficiency) and exhaust emissions were analysed at various engine speeds. All the tests were done under 75% full load. Furthermore, the volumetric blending ratios of biodiesel with conventional diesel fuel were set at 5, 10, 15, 20 and 30%. The results indicate that lower blends of biodiesel provide acceptable engine performance and even improve it. Meanwhile, exhaust emissions are much decreased. Finally, a 15% blend of castor oil-biodiesel was picked as the optimized blend of biodiesel-diesel. It was found that lower blends of castor biodiesel are an acceptable fuel alternative for the engine.

  13. Surveillance of a 2D Plane Area with 3D Deployed Cameras

    PubMed Central

    Fu, Yi-Ge; Zhou, Jie; Deng, Lei

    2014-01-01

    As the use of camera networks has expanded, camera placement to satisfy some quality assurance parameters (such as a good coverage ratio, an acceptable resolution constraints, an acceptable cost as low as possible, etc.) has become an important problem. The discrete camera deployment problem is NP-hard and many heuristic methods have been proposed to solve it, most of which make very simple assumptions. In this paper, we propose a probability inspired binary Particle Swarm Optimization (PI-BPSO) algorithm to solve a homogeneous camera network placement problem. We model the problem under some more realistic assumptions: (1) deploy the cameras in the 3D space while the surveillance area is restricted to a 2D ground plane; (2) deploy the minimal number of cameras to get a maximum visual coverage under more constraints, such as field of view (FOV) of the cameras and the minimum resolution constraints. We can simultaneously optimize the number and the configuration of the cameras through the introduction of a regulation item in the cost function. The simulation results showed the effectiveness of the proposed PI-BPSO algorithm. PMID:24469353

  14. Abstract‐to‐publication ratio for papers presented at scientific meetings: a quality marker for UK emergency medicine research

    PubMed Central

    Macmillan, Craig D; Moore, Anthony K; Cook, Ronald J; Pedley, David K

    2007-01-01

    Objectives To determine the publication rate of abstracts presented by UK emergency physicians at major emergency medicine meetings, and to identify the site of publication of papers. Method All abstracts presented to the annual scientific meetings of both the British Association of Emergency Medicine and the Faculty of Accident and Emergency Medicine between 2001 and 2002 were identified retrospectively from conference programmes. To identify whether the work relating to the abstract had been published in a peer‐reviewed journal, the Medline database (Ovid interface) was searched using the first and last authors as well as key words from the abstract. Results Of the 404 abstracts identified, 124 (30%) had been published as full articles. For abstracts presented in the oral sessions, 83 (57%) resulted in publication. A range of journals accepted papers for publication. Conclusion The abstract‐to‐publication ratio for UK emergency medicine is lower than for other specialties, but broadly similar to emergency medicine in the US and Australia. PMID:17513542

  15. Liquid fluorine/hydrazine rhenium thruster update

    NASA Technical Reports Server (NTRS)

    Appel, M. A.; Kaplan, R. B.; Tuffias, R. H.

    1983-01-01

    The status of a fluorine/hydrazine thruster development program is discussed. A solid rhenium metal sea-level thrust chamber was successfully fabricated and tested for a total run duration of 1075 s with 17 starts. Rhenium fabrication methods are discussed. A test program was conducted to evaluate performance and chamber cooling. Acceptable performance was reached and cooling was adequate. A flight-type injector was fabricated that achieved an average extrapolated performance value of 3608 N-s/kg (368 lbf-s/lbm). Altitude thrust chambers were fabricated. One chamber incorporates a rhenium combustor and nozzle with an area ratio of 15:1, and a columbium nozzle extension with area ratios from 15:1 to 60:1. The other chamber was fabricated completely with a carbon/carbon composite. Because of the attributes of rhenium for use in high-temperature applications, a program to provide the materials and processes technology needed to reliably fabricate and/or repair vapor-deposited rhenium parts of relatively large size and complex shape is recommended.

  16. The effect of zeolite treatment by acids on sodium adsorption ratio of coal seam gas water.

    PubMed

    Wang, Xiaoyu; Ozdemir, Orhan; Hampton, Marc A; Nguyen, Anh V; Do, Duong D

    2012-10-15

    Many coal seam gas (CSG) waters contain a sodium ion concentration which is too high relative to calcium and magnesium ions for environment acceptance. Natural zeolites can be used as a cheap and effective method to control sodium adsorption ratio (SAR, which is a measure of the relative preponderance of sodium to calcium and magnesium) due to its high cation exchange capacity. In this study, a natural zeolite from Queensland was examined for its potential to treat CSG water to remove sodium ions to lower SAR and reduce the pH value. The results demonstrate that acid activated zeolite at 30%wt solid ratio can reduce the sodium content from 563.0 to 182.7 ppm; the pH from 8.74 to 6.95; and SAR from 70.3 to 18.5. Based on the results of the batch experiments, the sodium adsorption capacity of the acid-treated zeolite is three times greater than that of the untreated zeolite. Both the untreated and acid-treated zeolite samples were characterized using zeta potential, surface characterization, DTA/TG and particle size distribution in order to explain their adsorption behaviours. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Electrochemical properties of TiO2-V2O5 nanocomposites as a high performance supercapacitors electrode material

    NASA Astrophysics Data System (ADS)

    Ray, Apurba; Roy, Atanu; Sadhukhan, Priyabrata; Chowdhury, Sreya Roy; Maji, Prasenjit; Bhattachrya, Swapan Kumar; Das, Sachindranath

    2018-06-01

    The individual components being ample, inexpensive and non-toxic material, TiO2-V2O5 has drawn more attention compared to other metal oxides. The cost-effective, non-toxic TiO2-V2O5 nanocomposites with various molar ratios of Ti and V have been synthesized through wet chemical method. Microstructure studies have been performed using X-ray diffraction (XRD), FESEM, HRTTEM and other spectroscopic (XPS, FTIR) techniques. The synthesized TiO2-V2O5 nanocomposite with molar ratio 10:20 exhibits 3D, mesoporous interlinked tube-like structure with excellent electrochemical properties by delivering highest specific capacitance of 310 F g-1 at 2 mV s-1 scan rate compared to individual TiO2 and V2O5 material. Increase in vanadium ratio plays a leading role to the chemical properties. The synergistic effects between TiO2 and V2O5 have also been observed in this work. Due to the excellent electrochemical as well as other acceptable performance, the porous interconnected tube like nanocomposite can be used for energy storage application mainly for pseudocapacitor electrode material.

  18. Evaluation of prostate cancer antigen 3 for detecting prostate cancer: a systematic review and meta-analysis

    NASA Astrophysics Data System (ADS)

    Cui, Yong; Cao, Wenzhou; Li, Quan; Shen, Hua; Liu, Chao; Deng, Junpeng; Xu, Jiangfeng; Shao, Qiang

    2016-05-01

    Previous studies indicate that prostate cancer antigen 3 (PCA3) is highly expressed in prostatic tumors. However, its clinical value has not been characterized. The aim of this study was to investigate the clinical value of the urine PCA3 test in the diagnosis of prostate cancer by pooling the published data. Clinical trials utilizing the urine PCA3 test for diagnosing prostate cancer were retrieved from PubMed and Embase. A total of 46 clinical trials including 12,295 subjects were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR) and area under the curve (AUC) were 0.65 (95% confidence interval [CI]: 0.63-0.66), 0.73 (95% CI: 0.72-0.74), 2.23 (95% CI: 1.91-2.62), 0.48 (95% CI: 0.44-0.52), 5.31 (95% CI: 4.19-6.73) and 0.75 (95% CI: 0.74-0.77), respectively. In conclusion, the urine PCA3 test has acceptable sensitivity and specificity for the diagnosis of prostate cancer and can be used as a non-invasive method for that purpose.

  19. Validation of Electrochemically Modulated Separations Performed On-Line with MC-ICP-MS for Uranium and Plutonium Isotopic Analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liezers, Martin; Olsen, Khris B.; Mitroshkov, Alexandre V.

    2010-08-11

    The most time consuming process in uranium or plutonium isotopic analyses is performing the requisite chromatographic separation of the actinides. Filament preparation for thermal ionization (TIMS) adds further delays, but is generally accepted due to the unmatched performance in trace isotopic analyses. Advances in Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) are beginning to rival the performance of TIMS. Methods, such as Electrochemically Modulated Separations (EMS) can efficiently pre-concentrate U or Pu quite selectively from small solution volumes in a matrix of 0.5 M nitric acid. When performed in-line with ICP-MS, the rapid analyte release from the electrode is fast,more » and large transient analyte signal enhancements of >100 fold can be achieved as compared to more conventional continuous nebulization of the original starting solution. This makes the approach ideal for very low level isotope ratio measurements. In this paper, some aspects of EMS performance are described. These include low level Pu isotope ratio behavior versus concentration by MC-ICP-MS and uranium rejection characteristics that are also important for reliable low level Pu isotope ratio determinations.« less

  20. [Tolerance and chronic acceptability of lupine (Lupinus albus var. Multolupa) flour for feeding of young adults].

    PubMed

    Gattás Zaror, V; Barrera Acevedo, G; Yáñez Soto, E; Uauy-Dagach Imbarack, R

    1990-12-01

    Cookies enriched with sweet lupin flour were tested for their acceptability and tolerance in young adults, and compared with control cookies. A number of hematological, hepatic and renal tests were performed, as well as the measurement of allergic response, in order to detect possible changes induced by lupin. The study included 31 young adults assigned to two groups which comprised males and females, with mean ages of 26 +/- 6.5, and 27 +/- 5.9 years, respectively. The protein and energy intakes of the subjects were calculated, prior to the study, using the methods of dietary history and the 24-hr recall method. The subjects were free of any abnormalities detectable by medical history, physical examination, biochemical and hematological tests. Body weight and height were measured before the beginning of the study. The ratio weight/height of the individuals was calculated using the Jelliffe's standards. The mean values for the calorie and protein intakes were 1,919 kcal (SD +/- 655) and 59.3 g (SD +/- 22.7). The calorie contents of the control and experimental cookies were 507 and 610 kcal respectively, while the protein contents were 8.4 g and 24.1 g, respectively. The body weight of subjects in both groups increased significantly during the study (P less than 0.01 and P less than 0.02). No significant changes were recorded for other anthropometric parameters, except for the tricipital skinfold (P less than 0.01). Changes observed in hematological parameters were judged to be unrelated to lupin flour. The acceptability and tolerance to high levels of lupin flour were good. The above-mentioned results show that sweet lupin flour is a good and safe source of energy and protein for adults.

  1. Evaluation of Models Describing the Growth of Nalidixic Acid-Resistant E. coli O157:H7 in Blanched Spinach and Iceberg Lettuce as a Function of Temperature

    PubMed Central

    Kim, Juhui; Chung, Hyunjung; Cho, Joonil; Yoon, Kisun

    2013-01-01

    The aim of this study was to model the growth of nalidixic acid-resistant E. coli O157:H7 (E. coli O157:H7NR) in blanched spinach and to evaluate model performance with an independent set of data for interpolation (8.5, 13, 15 and 27 °C) and for extrapolation (broth and fresh-cut iceberg lettuce) using the ratio method and the acceptable prediction zone method. The lag time (LT), specific growth rate (SGR) and maximum population density (MPD) obtained from each primary model were modeled as a function of temperature (7, 10, 17, 24, 30, and 36 °C) using Davey, square root, and polynomial models, respectively. At 7 °C, the populations of E. coli O157:H7NR increased in tryptic soy broth with nalidixic acid (TSBN), blanched spinach and fresh-cut iceberg lettuce, while the populations of E. coli O157:H7 decreased in TSB after 118 h of LT, indicating the risk of nalidixic acid-resistant strain of E. coli O157:H7 contaminated in ready-to-eat produce at refrigerated temperature. When the LT and SGR models of blanched spinach was extended to iceberg lettuce, all relative errors (percentage of RE = 100%) were inside the acceptable prediction zone and had an acceptable Bf and Af values. Thus, it was concluded that developed secondary models for E. coli O157:H7NR in blanched spinach were suitable for use in making predictions for fresh cut iceberg lettuce, but not for static TSBN in this work. PMID:23839062

  2. Flow and criticality in the open cycle gas core.

    NASA Technical Reports Server (NTRS)

    Kunze, J. F.; Lofthouse, J. H.

    1971-01-01

    A series of flowing gas experiments using air, argon, and freon has been conducted in Idaho. The purpose is to study methods of obtaining flow patterns which would create maximum possible system reactivity consistent with an acceptably low uranium to coolant-gas loss ratio. These have been conducted on both ?two-dimensional' and truly three-dimensional spherical configurations of diameters 18 to 42 inches. The larger diameter is that proposed for a minimum cost flowing gas critical experiment, and the size extremes make extrapolations to the large 6 and 8 foot diameter configurations more reliable. Results show that large enough inner gas (fuel) volume fractions can be achieved to attain criticality.

  3. Implant image quality in dental radiographs recorded using a customized imaging guide or a standard film holder.

    PubMed

    Schropp, Lars; Stavropoulos, Andreas; Spin-Neto, Rubens; Wenzel, Ann

    2012-01-01

    To compare a customized imaging guide and a standard film holder for obtaining optimally projected intraoral radiographs of dental implants. Intraoral radiographs of four screw-type implants with different inclination placed in an upper or lower dental phantom model were recorded by 32 groups of examiners after a short instruction in the use of the RB-RB/LB-LB mnemonic rule. Half of the examiners recorded the images using a standard film holder and the other half used a customized imaging guide. Each radiograph was assessed under blinded conditions with regard to rendering of the implant threads and was assigned to one of four quality categories: (1) perfect, (2) not perfect, but clinically acceptable, (3) not acceptable, and (4) hopeless. For the upper jaw, the same number of exposures per implant were made to achieve an acceptable image (P=0.86) by the standard film holder method (median=2) and the imaging guide method (median=2). For the lower jaw, medians for the imaging guide method and the film holder method were 1 and 2, respectively (P=0.004). For the imaging guide method, the first exposure was rated as perfect/acceptable in 62% of the cases and for the film holder method in 41% of the cases (P=0.013). After ≤ 2 exposures, 78% (imaging guide method) and 69% (film holder method) of the implant images were perfect/acceptable (P=0.23). The implant inclination did not have a major influence on the outcomes. Perfect or acceptable images were achieved after two exposures with the same frequency either using a customized imaging guide method or a standard film holder method. However, the use of a customized imaging guide method was overall significantly superior to a standard film holder method in terms of obtaining perfect or acceptable images with only one exposure. © 2011 John Wiley & Sons A/S.

  4. COMPARISON OF NONLINEAR DYNAMICS OPTIMIZATION METHODS FOR APS-U

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Y.; Borland, Michael

    Many different objectives and genetic algorithms have been proposed for storage ring nonlinear dynamics performance optimization. These optimization objectives include nonlinear chromaticities and driving/detuning terms, on-momentum and off-momentum dynamic acceptance, chromatic detuning, local momentum acceptance, variation of transverse invariant, Touschek lifetime, etc. In this paper, the effectiveness of several different optimization methods and objectives are compared for the nonlinear beam dynamics optimization of the Advanced Photon Source upgrade (APS-U) lattice. The optimized solutions from these different methods are preliminarily compared in terms of the dynamic acceptance, local momentum acceptance, chromatic detuning, and other performance measures.

  5. Acceptability of hypothetical dengue vaccines among travelers.

    PubMed

    Benoit, Christine M; MacLeod, William B; Hamer, Davidson H; Sanchez-Vegas, Carolina; Chen, Lin H; Wilson, Mary E; Karchmer, Adolf W; Yanni, Emad; Hochberg, Natasha S; Ooi, Winnie W; Kogelman, Laura; Barnett, Elizabeth D

    2013-01-01

    Dengue viruses have spread widely in recent decades and cause tens of millions of infections mostly in tropical and subtropical areas. Vaccine candidates are being studied aggressively and may be ready for licensure soon. We surveyed patients with past or upcoming travel to dengue-endemic countries to assess rates and determinants of acceptance for four hypothetical dengue vaccines with variable efficacy and adverse event (AE) profiles. Acceptance ratios were calculated for vaccines with varied efficacy and AE risk. Acceptance of the four hypothetical vaccines ranged from 54% for the vaccine with lower efficacy and serious AE risk to 95% for the vaccine with higher efficacy and minor AE risk. Given equal efficacy, vaccines with lower AE risk were better accepted than those with higher AE risk; given equivalent AE risk, vaccines with higher efficacy were better accepted than those with lower efficacy. History of Japanese encephalitis vaccination was associated with lower vaccine acceptance for one of the hypothetical vaccines. US-born travelers were more likely than non-US born travelers to accept a vaccine with 75% efficacy and a risk of minor AEs (p = 0.003). Compared with North American-born travelers, Asian- and African-born travelers were less likely to accept both vaccines with 75% efficacy. Most travelers would accept a safe and efficacious dengue vaccine if one were available. Travelers valued fewer potential AEs over increased vaccine efficacy. © 2013 International Society of Travel Medicine.

  6. Stability-indicating HPLC-DAD methods for determination of two binary mixtures: Rabeprazole sodium-mosapride citrate and rabeprazole sodium-itopride hydrochloride.

    PubMed

    El-Fatatry, Hamed M; Mabrouk, Mokhtar M; Hewala, Ismail I; Emam, Ehab H

    2014-08-01

    Two selective stability-indicating HPLC methods are described for determination of rabeprazole sodium (RZ)-mosapride citrate (MR) and RZ-itopride hydrochloride (IO) mixtures in the presence of their ICH-stress formed degradation products. Separations were achieved on X-Bridge C18 column using two mobile phases: the first for RZ-MR mixture consisted of acetonitrile: 0.025 M KH 2 PO 4 solution: TEA (30:69:1 v/v; pH 7.0); the second for RZ-IO mixture was at ratio of 25:74:1 (v/v; pH 9.25). The detection wavelength was 283 nm. The two methods were validated and validation acceptance criteria were met in all cases. Peak purity testing using contrast angle theory, relative absorbance and log  A versus the wavelengths plots were presented. The % recoveries of the intact drugs were between 99.1% and 102.2% with RSD% values less than 1.6%. Application of the proposed HPLC methods indicated that the methods could be adopted to follow the stability of their formulations.

  7. Targeted Coagulation Management in Severe Trauma: The Controversies and the Evidence.

    PubMed

    Winearls, James; Reade, Michael; Miles, Helen; Bulmer, Andrew; Campbell, Don; Görlinger, Klaus; Fraser, John F

    2016-10-01

    Hemorrhage in the setting of severe trauma is a leading cause of death worldwide. The pathophysiology of hemorrhage and coagulopathy in severe trauma is complex and remains poorly understood. Most clinicians currently treating trauma patients acknowledge the presence of a coagulopathy unique to trauma patients-trauma-induced coagulopathy (TIC)-independently associated with increased mortality. The complexity and incomplete understanding of TIC has resulted in significant controversy regarding optimum management. Although the majority of trauma centers utilize fixed-ratio massive transfusion protocols in severe traumatic hemorrhage, a widely accepted "ideal" transfusion ratio of blood to blood products remains elusive. The recent use of viscoelastic hemostatic assays (VHAs) to guide blood product replacement has further provoked debate as to the optimum transfusion strategy. The use of VHA to quantify the functional contributions of individual components of the coagulation system may permit targeted treatment of TIC but remains controversial and is unlikely to demonstrate a mortality benefit in light of the heterogeneity of the trauma population. Thus, VHA-guided algorithms as an alternative to fixed product ratios in trauma are not universally accepted, and a hybrid strategy starting with fixed-ratio transfusion and incorporating VHA data as they become available is favored by some institutions. We review the current evidence for the management of coagulopathy in trauma, the rationale behind the use of targeted and fixed-ratio approaches and explore future directions.

  8. Rheology of tissue conditioners.

    PubMed

    Murata, H; Hamada, T; Djulaeha, E; Nikawa, H

    1998-02-01

    Tissue conditioners can be used to condition abused tissues, record functional impressions, make temporary relinings, and for other clinical applications, mainly because of their specific viscoelasticity. However, little information is available on the rheology of the materials, manipulation, and suitability for various clinical applications. This study evaluated the gelation times, the viscoelastic properties after gelation of tissue conditioners, and the influence of the powder/liquid (P/L) ratio. Ten tissue conditioners were used and gelation times were obtained with an oscillating rheometer. A series of stress relaxation tests were also conducted to evaluate the viscoelastic properties after gelation and the changes with the passage of time by means of Maxwell model analogies. Significant differences were found in the gelation times and flow properties after gelation among the materials mixed with the P/L ratios recommended by the manufacturers. The flow properties tended to increase with time of storage. Large differences in the limits of the clinically acceptable P/L ratios and the adjustable limits of elasticity and viscosity by altering P/L ratios were found among the materials. The results suggested that each material should be selected according to each clinical purpose because of the wide ranges of viscoelastic properties and changes in viscoelasticity with time among the materials. Furthermore, gelation times and the viscoelastic properties after gelation can be controlled to improve handling and suit various applications by altering the P/L ratios within the acceptable limits.

  9. Modeling and Simulation in Healthcare Future Directions

    DTIC Science & Technology

    2010-07-13

    Collaborate Evidence Based Medicine is . . . The Scientific Method as Applied to Medicine The Evidence IS the Science In order to accept evidence ... based medicine . . . we must accept the current method in Science The Scientific Method is Dead Scientific Method . . . . . . is DEAD? Not necessarily

  10. Using Rose’s metal alloy as a pinhole collimator material in preclinical small-animal imaging: A Monte Carlo evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterson, Mikael, E-mail: Mikael.Peterson@med.lu.se; Strand, Sven-Erik; Ljungberg, Michael

    Purpose: Pinhole collimation is the most common method of high-resolution preclinical single photon emission computed tomography imaging. The collimators are usually constructed from dense materials with high atomic numbers, such as gold and platinum, which are expensive and not always flexible in the fabrication step. In this work, the authors have investigated the properties of a fusible alloy called Rose’s metal and its potential in pinhole preclinical imaging. When compared to current standard pinhole materials such as gold and platinum, Rose’s metal has a lower density and a relatively low effective atomic number. However, it is inexpensive, has a lowmore » melting point, and does not contract when solidifying. Once cast, the piece can be machined with high precision. The aim of this study was to evaluate the imaging properties for Rose’s metal and compare them with those of standard materials. Methods: After validating their Monte Carlo code by comparing its results with published data and the results from analytical calculations, they investigated different pinhole geometries by varying the collimator material, acceptance angle, aperture diameter, and photon incident angle. The penetration-to-scatter and penetration-to-total component ratios, sensitivity, and the spatial resolution were determined for gold, tungsten, and Rose’s metal for two radionuclides, {sup 99}Tc{sup m} and {sup 125}I. Results: The Rose’s metal pinhole-imaging simulations show higher penetration/total and scatter/total ratios. For example, the penetration/total is 50% for gold and 75% for Rose’s metal when simulating {sup 99}Tc{sup m} with a 0.3 mm aperture diameter and a 60° acceptance angle. However, the degradation in spatial resolution remained below 10% relative to the spatial resolution for gold for acceptance angles below 40° and aperture diameters larger than 0.5 mm. Conclusions: Extra penetration and scatter associated with Rose’s metal contribute to degradation in the spatial resolution, but this degradation is not always substantial. The most important factor besides the collimator material was the acceptance angle. This should be kept to a minimum to prevent unnecessary scatter and penetration. For {sup 125}I, the difference in spatial resolution between gold and Rose’s metal is very small, 2.2% in the worst-case scenario. Based on these results, the authors conclude that Rose’s metal is an alternative to standard materials not only for low-energy photon imaging but also for medium-energy applications that require low-cost, flexible pinhole configurations and designs, and that can tolerate a degraded spatial resolution.« less

  11. Acceptability of HIV Prevention Information Delivered Through Established Geosocial Networking Mobile Applications to Men Who Have Sex With Men.

    PubMed

    Czarny, Heather N; Broaddus, Michelle R

    2017-11-01

    Geosocial networking (GSN) applications could disseminate HIV prevention information to thousands of men who have sex with men (MSM); however, acceptability of the type of information, methods, and frequency of information delivery are unknown. Acceptability of these constructs were assessed through a survey of 224 MSM at the Milwaukee Pridefest. All types of information were found acceptable. A sexual health section and self-seeking information were the most acceptable method and frequency of delivery. Demographics and differences in app usage did not correlate to acceptability. Continued research focusing on the feasibility of incorporating HIV prevention information into GSN applications is needed.

  12. Evolving concepts on adjusting human resting energy expenditure measurements for body size.

    PubMed

    Heymsfield, S B; Thomas, D; Bosy-Westphal, A; Shen, W; Peterson, C M; Müller, M J

    2012-11-01

    Establishing if an adult's resting energy expenditure (REE) is high or low for their body size is a pervasive question in nutrition research. Early workers applied body mass and height as size measures and formulated the Surface Law and Kleiber's Law, although each has limitations when adjusting REE. Body composition methods introduced during the mid-20th century provided a new opportunity to identify metabolically homogeneous 'active' compartments. These compartments all show improved correlations with REE estimates over body mass-height approaches, but collectively share a common limitation: REE-body composition ratios are not 'constant' but vary across men and women and with race, age and body size. The now-accepted alternative to ratio-based norms is to adjust for predictors by applying regression models to calculate 'residuals' that establish if an REE is relatively high or low. The distinguishing feature of statistical REE-body composition models is a 'non-zero' intercept of unknown origin. The recent introduction of imaging methods has allowed development of physiological tissue-organ-based REE prediction models. Herein, we apply these imaging methods to provide a mechanistic explanation, supported by experimental data, for the non-zero intercept phenomenon and, in that context, propose future research directions for establishing between-subject differences in relative energy metabolism. © 2012 The Authors. obesity reviews © 2012 International Association for the Study of Obesity.

  13. Tip Characterization Method using Multi-feature Characterizer for CD-AFM

    PubMed Central

    Orji, Ndubuisi G.; Itoh, Hiroshi; Wang, Chumei; Dixson, Ronald G.; Walecki, Peter S.; Schmidt, Sebastian W.; Irmer, Bernd

    2016-01-01

    In atomic force microscopy (AFM) metrology, the tip is a key source of uncertainty. Images taken with an AFM show a change in feature width and shape that depends on tip geometry. This geometric dilation is more pronounced when measuring features with high aspect ratios, and makes it difficult to obtain absolute dimensions. In order to accurately measure nanoscale features using an AFM, the tip dimensions should be known with a high degree of precision. We evaluate a new AFM tip characterizer, and apply it to critical dimension AFM (CD-AFM) tips used for high aspect ratio features. The characterizer is made up of comb-shaped lines and spaces, and includes a series of gratings that could be used as an integrated nanoscale length reference. We also demonstrate a simulation method that could be used to specify what range of tip sizes and shapes the characterizer can measure. Our experiments show that for non re-entrant features, the results obtained with this characterizer are consistent to 1 nm with the results obtained by using widely accepted but slower methods that are common practice in CD-AFM metrology. A validation of the integrated length standard using displacement interferometry indicates a uniformity of better than 0.75%, suggesting that the sample could be used as highly accurate and SI traceable lateral scale for the whole evaluation process. PMID:26720439

  14. Social Acceptability of Menstrual-Care Training Methods for Young Women with Developmental Disabilities.

    ERIC Educational Resources Information Center

    Epps, Susan; And Others

    1990-01-01

    The acceptability of two different training methods (simulation training using a doll and simulation training on self) for teaching menstrual hygiene skills to young women with developmental disabilities was evaluated in two experiments. Results suggested that opinions about treatment acceptability should be obtained from both professional and…

  15. Quantifying glenoid bone loss in anterior shoulder instability: reliability and accuracy of 2-dimensional and 3-dimensional computed tomography measurement techniques.

    PubMed

    Bois, Aaron J; Fening, Stephen D; Polster, Josh; Jones, Morgan H; Miniaci, Anthony

    2012-11-01

    Glenoid support is critical for stability of the glenohumeral joint. An accepted noninvasive method of quantifying glenoid bone loss does not exist. To perform independent evaluations of the reliability and accuracy of standard 2-dimensional (2-D) and 3-dimensional (3-D) computed tomography (CT) measurements of glenoid bone deficiency. Descriptive laboratory study. Two sawbone models were used; one served as a model for 2 anterior glenoid defects and the other for 2 anteroinferior defects. For each scapular model, predefect and defect data were collected for a total of 6 data sets. Each sample underwent 3-D laser scanning followed by CT scanning. Six physicians measured linear indicators of bone loss (defect length and width-to-length ratio) on both 2-D and 3-D CT and quantified bone loss using the glenoid index method on 2-D CT and using the glenoid index, ratio, and Pico methods on 3-D CT. The intraclass correlation coefficient (ICC) was used to assess agreement, and percentage error was used to compare radiographic and true measurements. With use of 2-D CT, the glenoid index and defect length measurements had the least percentage error (-4.13% and 7.68%, respectively); agreement was very good (ICC, .81) for defect length only. With use of 3-D CT, defect length (0.29%) and the Pico(1) method (4.93%) had the least percentage error. Agreement was very good for all linear indicators of bone loss (range, .85-.90) and for the ratio linear and Pico surface area methods used to quantify bone loss (range, .84-.98). Overall, 3-D CT results demonstrated better agreement and accuracy compared to 2-D CT. None of the methods assessed in this study using 2-D CT was found to be valid, and therefore, 2-D CT is not recommended for these methods. However, the length of glenoid defects can be reliably and accurately measured on 3-D CT. The Pico and ratio techniques are most reliable; however, the Pico(1) method accurately quantifies glenoid bone loss in both the anterior and anteroinferior locations. Future work is required to implement valid imaging techniques of glenoid bone loss into clinical practice. This is one of the only studies to date that has investigated both the reliability and accuracy of multiple indicators and quantification methods that evaluate glenoid bone loss in anterior glenohumeral instability. These data are critical to ensure valid methods are used for preoperative assessment and to determine when a glenoid bone augmentation procedure is indicated.

  16. Extraction, scrub, and strip test results for the salt waste processing facility caustic side solvent extraction solvent example

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T. B.

    An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D(Cs) measured 12.9, exceeding the required value of 8. This value is consistent with results from previousmore » ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.« less

  17. Luminosity determination in pp collisions at $$\\sqrt{s} = 7$$ TeV using the ATLAS detector at the LHC

    DOE PAGES

    Aad, G.; Abbott, B.; Abdallah, J.; ...

    2011-04-27

    Measurements of luminosity obtained using the ATLAS detector during early running of the Large Hadron Collider (LHC) at √s = 7 TeV are presented. The luminosity is independently determined using several detectors and multiple algorithms, each having different acceptances, systematic uncertainties and sensitivity to background. The ratios of the luminosities obtained from these methods are monitored as a function of time and of μ, the average number of inelastic interactions per bunch crossing. Residual time- and μ-dependence between the methods is less than 2% for 0 < μ < 2.5. Absolute luminosity calibrations, performed using beam separation scans, have amore » common systematic uncertainty of ±11%, dominated by the measurement of the LHC beam currents. After calibration, the luminosities obtained from the different methods differ by at most ±2%. The visible cross sections measured using the beam scans are compared to predictions obtained with the PYTHIA and PHOJET event generators and the ATLAS detector simulation.« less

  18. A novel approach for in vitro meat production.

    PubMed

    Pandurangan, Muthuraman; Kim, Doo Hwan

    2015-07-01

    The present review describes the possibility of in vitro meat production with the help of advanced co-culturing methods. In vitro meat production method could be a possible alternative for the conventional meat production. Originally, the research on in vitro meat production was initiated by the National Aeronautics and Space Administration (NASA) for space voyages. The required key qualities for accepting in vitro meat for consumption would be good efficiency ratio, increased protein synthesis rate in skeletal muscles, and mimicking the conventional meat qualities. In vitro culturing of meat is possible with the use of skeletal muscle tissue engineering, stem cell, cell co-culture, and tissue culture methods. Co-culture of myoblast and fibroblast is believed as one of the major techniques for in vitro meat production. In our lab, we have co-cultured myoblast and fibroblast. We believe that a billion pounds of in vitro meat could be produced from one animal for consumption. However, we require a great deal of research on in vitro meat production.

  19. Effect of Oregano Essential Oil and Aqueous Oregano Infusion Application on Microbiological Properties of Samarella (Tsamarella), a Traditional Meat Product of Cyprus.

    PubMed

    Ulusoy, Beyza; Hecer, Canan; Kaynarca, Doruk; Berkan, Şifa

    2018-03-21

    Different types of dried meat products manufactured by different drying and curing methods are very common and well-known with a long history all over the world. Samarella (tsamarella) is one of these products and is famous among traditionally produced meat products in Cypriot gastronomy. The aim of this study was to investigate the effect of oregano essential oil (OEO) and aqueous oregano infusion (AOI) applications on the microbiological properties of samarella. In order to carry out this study, traditional methods were followed for experimental production of samarella. As a result of this study, five percent OEO application was found to be more effective to reduce microbiological counts but this ratio of OEO application was not accepted by panelists. According to all microbiological results correlated with the sensorial scores, it is concluded that one percent OEO application can be used for samarella production as an alternative preservative method.

  20. Effect of Oregano Essential Oil and Aqueous Oregano Infusion Application on Microbiological Properties of Samarella (Tsamarella), a Traditional Meat Product of Cyprus

    PubMed Central

    Hecer, Canan; Kaynarca, Doruk; Berkan, Şifa

    2018-01-01

    Different types of dried meat products manufactured by different drying and curing methods are very common and well-known with a long history all over the world. Samarella (tsamarella) is one of these products and is famous among traditionally produced meat products in Cypriot gastronomy. The aim of this study was to investigate the effect of oregano essential oil (OEO) and aqueous oregano infusion (AOI) applications on the microbiological properties of samarella. In order to carry out this study, traditional methods were followed for experimental production of samarella. As a result of this study, five percent OEO application was found to be more effective to reduce microbiological counts but this ratio of OEO application was not accepted by panelists. According to all microbiological results correlated with the sensorial scores, it is concluded that one percent OEO application can be used for samarella production as an alternative preservative method. PMID:29561804

  1. Simultaneous Determination of Potassium Sorbate, Sodium Benzoate, Quinoline Yellow and Sunset Yellow in Lemonades and Lemon Sauces by HPLC Using Experimental Design.

    PubMed

    Dinç Zor, Şule; Aşçı, Bürge; Aksu Dönmez, Özlem; Yıldırım Küçükkaraca, Dilek

    2016-07-01

    In this study, development and validation of a HPLC method was described for simultaneous determination of potassium sorbate, sodium benzoate, quinoline yellow and sunset yellow. A Box-Behnken design using three variables at three levels was employed to determine the optimum conditions of chromatographic separation: pH of mobile phase, 6.0-7.0; flow rate, 0.8-1.2 mL min(-1) and the ratio of mobile phase composed of a 0.025 M sodium acetate/acetic acid buffer, 80-90%. Resolution was chosen as a response. The optimized method was validated for linearity, the limits of detection and quantification, accuracy, precision and stability. All the validation parameters were within the acceptance range. The applicability of the developed method to the determination of these food additives in commercial lemonade and lemon sauce samples was successfully demonstrated. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. MO-FG-204-08: Optimization-Based Image Reconstruction From Unevenly Distributed Sparse Projection Views

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Huiqiao; Yang, Yi; Tang, Xiangyang

    2015-06-15

    Purpose: Optimization-based reconstruction has been proposed and investigated for reconstructing CT images from sparse views, as such the radiation dose can be substantially reduced while maintaining acceptable image quality. The investigation has so far focused on reconstruction from evenly distributed sparse views. Recognizing the clinical situations wherein only unevenly sparse views are available, e.g., image guided radiation therapy, CT perfusion and multi-cycle cardiovascular imaging, we investigate the performance of optimization-based image reconstruction from unevenly sparse projection views in this work. Methods: The investigation is carried out using the FORBILD and an anthropomorphic head phantoms. In the study, 82 views, whichmore » are evenly sorted out from a full (360°) axial CT scan consisting of 984 views, form sub-scan I. Another 82 views are sorted out in a similar manner to form sub-scan II. As such, a CT scan with sparse (164) views at 1:6 ratio are formed. By shifting the two sub-scans relatively in view angulation, a CT scan with unevenly distributed sparse (164) views at 1:6 ratio are formed. An optimization-based method is implemented to reconstruct images from the unevenly distributed views. By taking the FBP reconstruction from the full scan (984 views) as the reference, the root mean square (RMS) between the reference and the optimization-based reconstruction is used to evaluate the performance quantitatively. Results: In visual inspection, the optimization-based method outperforms the FBP substantially in the reconstruction from unevenly distributed, which are quantitatively verified by the RMS gauged globally and in ROIs in both the FORBILD and anthropomorphic head phantoms. The RMS increases with increasing severity in the uneven angular distribution, especially in the case of anthropomorphic head phantom. Conclusion: The optimization-based image reconstruction can save radiation dose up to 12-fold while providing acceptable image quality for advanced clinical applications wherein only unevenly distributed sparse views are available. Research Grants: W81XWH-12-1-0138 (DoD), Sinovision Technologies.« less

  3. Novel spectrophotometric methods for simultaneous determination of Amlodipine, Valsartan and Hydrochlorothiazide in their ternary mixture

    NASA Astrophysics Data System (ADS)

    Lotfy, Hayam M.; Hegazy, Maha A.; Mowaka, Shereen; Mohamed, Ekram Hany

    2015-04-01

    This work represents a comparative study of two smart spectrophotometric techniques namely; successive resolution and progressive resolution for the simultaneous determination of ternary mixtures of Amlodipine (AML), Hydrochlorothiazide (HCT) and Valsartan (VAL) without prior separation steps. These techniques consist of several consecutive steps utilizing zero and/or ratio and/or derivative spectra. By applying successive spectrum subtraction coupled with constant multiplication method, the proposed drugs were obtained in their zero order absorption spectra and determined at their maxima 237.6 nm, 270.5 nm and 250 nm for AML, HCT and VAL, respectively; while by applying successive derivative subtraction they were obtained in their first derivative spectra and determined at P230.8-246, P261.4-278.2, P233.7-246.8 for AML, HCT and VAL respectively. While in the progressive resolution, the concentrations of the components were determined progressively from the same zero order absorption spectrum using absorbance subtraction coupled with absorptivity factor methods or from the same ratio spectrum using only one divisor via amplitude modulation method can be used for the determination of ternary mixtures using only one divisor where the concentrations of the components are determined progressively. The proposed methods were checked using laboratory-prepared mixtures and were successfully applied for the analysis of pharmaceutical formulation containing the cited drugs. Moreover comparative study between spectrum addition technique as a novel enrichment technique and a well established one namely spiking technique was adopted for the analysis of pharmaceutical formulations containing low concentration of AML. The methods were validated as per ICH guidelines where accuracy, precision and specificity were found to be within their acceptable limits. The results obtained from the proposed methods were statistically compared with the reported one where no significant difference was observed.

  4. An enzyme-linked immunosorbent assay for monoester-type aconitic alkaloids and its application in the pharmacokinetic study of benzoylhypaconine in rats.

    PubMed

    Liu, Can-Can; Xu, Yun-Hui; Yuan, Shuai; Xu, Yu; Hua, Mo-Li

    2018-04-01

    A new enzyme-linked immunosorbent assay (ELISA) method for quantitative determination of monoester-type aconitic alkaloids was developed. The antibodies derived from the immunogen of benzoylmesaconine (BM) could be electively affined to benzoylaconitine-type alkaloids with an ester bond (14-benzoyl-), especially to benzoylhypaconine (BH, 140.02% of cross-reactivity). The effective working range of BH was 1 ng/ml to 5 μg/ml; the lower limit of detection and the quantification were 0.35 and 0.97 ng/ml, respectively. The values of CV for intra-day and inter-day assays and recovery ratios were in acceptable ranges. The results of stability experiments were also satisfactory. This validated method was employed for pharmacokinetic study of BH in rats and the bioavailability orally administered was estimated to be 16.3%.

  5. Study of blade aspect ratio on a compressor front stage aerodynamic and mechanical design report

    NASA Technical Reports Server (NTRS)

    Burger, G. D.; Lee, D.; Snow, D. W.

    1979-01-01

    A single stage compressor was designed with the intent of demonstrating that, for a tip speed and hub-tip ratio typical of an advanced core compressor front stage, the use of low aspect ratio can permit high levels of blade loading to be achieved at an acceptable level of efficiency. The design pressure ratio is 1.8 at an adiabatic efficiency of 88.5 percent. Both rotor and stator have multiple-circular-arc airfoil sections. Variable IGV and stator vanes permit low speed matching adjustments. The design incorporates an inlet duct representative of an engine transition duct between fan and high pressure compressor.

  6. A comparative study of novel spectrophotometric methods based on isosbestic points; application on a pharmaceutical ternary mixture

    NASA Astrophysics Data System (ADS)

    Lotfy, Hayam M.; Saleh, Sarah S.; Hassan, Nagiba Y.; Salem, Hesham

    This work represents the application of the isosbestic points present in different absorption spectra. Three novel spectrophotometric methods were developed, the first method is the absorption subtraction method (AS) utilizing the isosbestic point in zero-order absorption spectra; the second method is the amplitude modulation method (AM) utilizing the isosbestic point in ratio spectra; and third method is the amplitude summation method (A-Sum) utilizing the isosbestic point in derivative spectra. The three methods were applied for the analysis of the ternary mixture of chloramphenicol (CHL), dexamethasone sodium phosphate (DXM) and tetryzoline hydrochloride (TZH) in eye drops in the presence of benzalkonium chloride as a preservative. The components at the isosbestic point were determined using the corresponding unified regression equation at this point with no need for a complementary method. The obtained results were statistically compared to each other and to that of the developed PLS model. The specificity of the developed methods was investigated by analyzing laboratory prepared mixtures and the combined dosage form. The methods were validated as per ICH guidelines where accuracy, repeatability, inter-day precision and robustness were found to be within the acceptable limits. The results obtained from the proposed methods were statistically compared with official ones where no significant difference was observed.

  7. "Show me the money": a fair criticism of economic studies on inhaled bronchodilators for COPD.

    PubMed

    Kostikas, Konstantinos; Bouros, Demosthenes

    2010-09-15

    Chronic obstructive pulmonary disease (COPD) represents a significant burden for healthcare systems that is expected to grow further in the future. Inhaled long-acting bronchodilators, including tiotropium, represent the cornerstone of management of COPD patients. Economic studies evaluating the cost-effectiveness ratio of inhaled bronchodilators have to take into account several parameters, including the reduction of COPD exacerbations and related hospitalizations, as well as disease modification and improvement in quality of life and mortality. At an era when the healthcare resources are unlikely to grow as quickly as demand, economic analyses remain the cornerstone for the justification of the broad use of medication with an acceptable cost-effectiveness ratio. The greatest importance of such studies in COPD is the identification of subgroups of patients that will have the most benefit with an acceptable cost-effectiveness ratio for the healthcare providers. The development of models that will incorporate a global evaluation of the different aspects of this multi-component disease, in order to provide the best available care to each individual patient is urgently needed.

  8. Using instrumental (CIE and reflectance) measures to predict consumers' acceptance of beef colour.

    PubMed

    Holman, Benjamin W B; van de Ven, Remy J; Mao, Yanwei; Coombs, Cassius E O; Hopkins, David L

    2017-05-01

    We aimed to establish colorimetric thresholds based upon the capacity for instrumental measures to predict consumer satisfaction with beef colour. A web-based survey was used to distribute standardised photographs of beef M. longissimus lumborum with known colorimetrics (L*, a*, b*, hue, chroma, ratio of reflectance at 630nm and 580nm, and estimated deoxymyoglobin, oxymyoglobin and metmyoglobin concentrations) for scrutiny. Consumer demographics and perceived importance of colour to beef value were also evaluated. It was found that a* provided the most simple and robust prediction of beef colour acceptability. Beef colour was considered acceptable (with 95% acceptance) when a* values were equal to or above 14.5. Demographic effects on this threshold were negligible, but consumer nationality and gender did contribute to variation in the relative importance of colour to beef value. These results provide future beef colour studies with context to interpret objective colour measures in terms of consumer acceptance and market appeal. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  9. HF Meander-Line Antenna Simulations and Investigations for NVIS on a HMMV

    DTIC Science & Technology

    2016-09-28

    power   transfer  at  frequencies  of   interests  [10].       Graph  1.  Conventional  MLA  input  impedance...the  ratio  of  accepted   power  versus  the  radiated   power  of  a   simulated  antenna  after  the  equation...the  antenna  (x,  y,  z   coordinates)  and  !""=  the  accepted  

  10. External quality assessment program for detection of glucose-6-phosphate dehydrogenase deficiency in the Guangxi region.

    PubMed

    Tang, Juan; Zhou, Xiangyang; Liu, Xiaochun; Ning, Leping; Zhou, Weiya; He, Yi

    2017-09-01

    The aim of this study is to improve the quality of testing for glucose-6-phosphate dehydrogenase (G6PD) deficiency through evaluation and analysis of the laboratory tests for G6PD activity. External quality assessment (EQA) was carried out twice per year with five samples each from 2014 to 2016. Samples were used for quantitative and qualitative assays. Quantitative results were collected, qualitative results were determined with reference values, and information about methods, reagents and instruments from participating laboratories within the required time. Laboratory performance scores, coefficient of variation (CV), and the rates of false negative and positive results were calculated. As a result, a total of 2,834 cases of negative quality control (QC) samples and 2,451 cases of positive QC samples were assessed, where the rates of false negative and false positive results were 1.31% (37/2,834) and 1.34% (33/2,451), respectively. Quantitative results indicated an increasing trend in testing quality, which were consistent with conclusions based on the comparison of EQA full-score and acceptable ratio in six assessments. The 2nd assay in 2016 had the best full-score ratio of 68.9% (135/196) and best acceptable ratio of 84.2% (165/196). There was a decreasing trend in the average CV of six reagents produced in China, and the range of average CV increased to 14.6-23.6% in 2016. The average CV of low level and high level samples was 22.5% and 15.3%, respectively, demonstrating that samples with low G6PD activity have greater interlaboratory CV values. In conclusion, laboratories improved their testing quality and provided better diagnostic service for G6PD deficiency in areas with high incidence after participation in the EQA program in the Guangxi region.

  11. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  12. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  13. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  14. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  15. 10 CFR 26.91 - Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Acceptable devices for conducting initial and confirmatory tests for alcohol and methods of use. 26.91 Section 26.91 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting Specimens for Testing § 26.91 Acceptable devices for conducting initial...

  16. Paired comparison estimates of willingness to accept versus contingent valuation estimates of willingness to pay

    Treesearch

    John B. Loomis; George Peterson; Patricia A. Champ; Thomas C. Brown; Beatrice Lucero

    1998-01-01

    Estimating empirical measures of an individual's willingness to accept that are consistent with conventional economic theory, has proven difficult. The method of paired comparison offers a promising approach to estimate willingness to accept. This method involves having individuals make binary choices between receiving a particular good or a sum of money....

  17. Wavelet-Based Artifact Identification and Separation Technique for EEG Signals during Galvanic Vestibular Stimulation

    PubMed Central

    Adib, Mani; Cretu, Edmond

    2013-01-01

    We present a new method for removing artifacts in electroencephalography (EEG) records during Galvanic Vestibular Stimulation (GVS). The main challenge in exploiting GVS is to understand how the stimulus acts as an input to brain. We used EEG to monitor the brain and elicit the GVS reflexes. However, GVS current distribution throughout the scalp generates an artifact on EEG signals. We need to eliminate this artifact to be able to analyze the EEG signals during GVS. We propose a novel method to estimate the contribution of the GVS current in the EEG signals at each electrode by combining time-series regression methods with wavelet decomposition methods. We use wavelet transform to project the recorded EEG signal into various frequency bands and then estimate the GVS current distribution in each frequency band. The proposed method was optimized using simulated signals, and its performance was compared to well-accepted artifact removal methods such as ICA-based methods and adaptive filters. The results show that the proposed method has better performance in removing GVS artifacts, compared to the others. Using the proposed method, a higher signal to artifact ratio of −1.625 dB was achieved, which outperformed other methods such as ICA-based methods, regression methods, and adaptive filters. PMID:23956786

  18. Experimental characterization of the AFIT neutron facility. Master's thesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lessard, O.J.

    1993-09-01

    AFIT's Neutron Facility was characterized for room-return neutrons using a (252)Cf source and a Bonner sphere spectrometer with three experimental models, the shadow shield, the Eisenhauer, Schwartz, and Johnson (ESJ), and the polynomial models. The free-field fluences at one meter from the ESJ and polynomial models were compared to the equivalent value from the accepted experimental shadow shield model to determine the suitability of the models in the AFIT facility. The polynomial model behaved erratically, as expected, while the ESJ model compared to within 4.8% of the shadow shield model results for the four Bonner sphere calibration. The ratio ofmore » total fluence to free-field fluence at one meter for the ESJ model was then compared to the equivalent ratio obtained by a Monte Cario Neutron-Photon transport code (MCNP), an accepted computational model. The ESJ model compared to within 6.2% of the MCNP results. AFIT's fluence ratios were compared to equivalent ratios reported by three other neutron facilities which verified that AFIT's results fit previously published trends based on room volumes. The ESJ model appeared adequate for health physics applications and was chosen was chosen for calibration of the AFIT facility. Neutron Detector, Bonner Sphere, Neutron Dosimetry, Room Characterization.« less

  19. Fortification of Wheat Bread with 3-7% Defatted Soy Flour Improves Formulation, Organoleptic Characteristics, and Rat Growth Rate

    PubMed Central

    Mahmoodi, Mohammad Reza; Mashayekh, Morteza; Entezari, Mohammad Hasan

    2014-01-01

    Background: The present study designed to test effects of defatted soy-fortified wheat bread on the organoleptic properties as well as influences on rat growth rate. Methods: Defatted soy flour (DSF) was blended with wheat flour with extraction rate of 82-84% at 3, 7, and 7% levels plus 3% sugar. Bread produced with these blends compared with regular Taftoon bread and was tested for chemical and organoleptic characteristics. The organoleptic characteristics of blends consist of taste and flavor, crust texture, fragrance and aroma, appearance, bendability, and overall acceptability were determined through taste panel by 213 judges. Forty Sprague Dawley rats were randomly given codes and allocated to different groups via tables with random numbers to feed on three DSF-fortified bread blends and control bread for 30 days. Results: The blending of wheat flour with DSF altered the organoleptic properties of breads. Addition of DSF increased significantly the protein and ash content of the bread (P < 0.05). Organoleptic test indicates that the best formulation is between 3 and 7% fortifications of DSF blends. In biological evaluation, rats fed the control diet had the lowest body weight gain and their food efficiency ratio was significantly different (P < 0.05) in compare with 7% DSF-fortified blend. Conclusions: It was concluded that overall acceptability score significantly decreased with increasing DSF substitution level. Rats fed 7% DSF-fortified blend showed privileged food efficiency ratio. Then, the best formulation is between 3 and 7% DSF bread. This formulation can nourish all human at risk of malnutrition. PMID:24554990

  20. Case finding of lifestyle and mental health disorders in primary care: validation of the ‘CHAT’ tool

    PubMed Central

    Goodyear-Smith, Felicity; Coupe, Nicole M; Arroll, Bruce; Elley, C Raina; Sullivan, Sean; McGill, Anne-Thea

    2008-01-01

    Background Primary care is accessible and ideally placed for case finding of patients with lifestyle and mental health risk factors and subsequent intervention. The short self-administered Case-finding and Help Assessment Tool (CHAT) was developed for lifestyle and mental health assessment of adult patients in primary health care. This tool checks for tobacco use, alcohol and other drug misuse, problem gambling, depression, anxiety and stress, abuse, anger problems, inactivity, and eating disorders. It is well accepted by patients, GPs and nurses. Aim To assess criterion-based validity of CHAT against a composite gold standard. Design of study Conducted according to the Standards for Reporting of Diagnostic Accuracy statement for diagnostic tests. Setting Primary care practices in Auckland, New Zealand. Method One thousand consecutive adult patients completed CHAT and a composite gold standard. Sensitivities, specificities, positive and negative predictive values, and likelihood ratios were calculated. Results Response rates for each item ranged from 79.6 to 99.8%. CHAT was sensitive and specific for almost all issues screened, except exercise and eating disorders. Sensitivity ranged from 96% (95% confidence interval [CI] = 87 to 99%) for major depression to 26% (95% CI = 22 to 30%) for exercise. Specificity ranged from 97% (95% CI = 96 to 98%) for problem gambling and problem drug use to 40% (95% CI = 36 to 45%) for exercise. All had high likelihood ratios (3–30), except exercise and eating disorders. Conclusion CHAT is a valid and acceptable case-finding tool for most common lifestyle and mental health conditions. PMID:18186993

  1. Socio-cultural factors, gender roles and religious ideologies contributing to Caesarian-section refusal in Nigeria.

    PubMed

    Ugwu, Nnanna U; de Kok, Bregje

    2015-08-12

    The death of women from pregnancy-related causes is a serious challenge that international development initiatives, including the Millennium Development Goals, have been trying to redress for decades. The majority of these pregnancy-related deaths occur in developing countries especially in Sub-Saharan Africa. The provision of Emergency Obstetric Care (EmOC), including Caesarean section (CS) has been identified as one of the key ingredients necessary for the reduction of high maternal mortality ratios. However, it appears that creating access to EmOC facilities is not all that is required to reduce maternal mortality: socio-cultural issues in Sub-Saharan countries including Nigeria seem to deter women from accepting CS. This study seeks to explore some of the socio-cultural concerns that reinforce delays and non-acceptance of CS in a Nigerian community. This is a mixed method study that combined both qualitative and quantitative strategies of enquiry. The hospital's delivery records from 2006-2010 provided data for quantitative analysis. This quantitative data was supplemented with prospective data collected during one month. Semi-structured interviews, focus group discussions (FGD) and informal observations served as the sources of data on the qualitative end. In total, 22% of maternity clients refused CS and more than 90% of the CSs in the focal hospital were emergencies which may indicate late arrival at the hospital after seeking assistance elsewhere. The qualitative analysis reveals that socio-cultural meanings informed by gender and religious ideologies, the relational consequences of having a C-section, and the role of alternative providers are some key factors which influence when, where and whether women will accept C-section or not. There is need to find means of facilitating necessary CS by addressing the prevailing socio-cultural norms and expectations that hinder its acceptance. Engaging and guiding alternative providers (traditional birth attendants and faith healers) who wield much power in their communities, will be important to minimize delays and improve cultural acceptability of CS.

  2. Knowledge sharing to facilitate regulatory decision-making in regard to alternatives to animal testing: Report of an EPAA workshop.

    PubMed

    Ramirez, Tzutzuy; Beken, Sonja; Chlebus, Magda; Ellis, Graham; Griesinger, Claudius; De Jonghe, Sandra; Manou, Irene; Mehling, Annette; Reisinger, Kerstin; Rossi, Laura H; van Benthem, Jan; van der Laan, Jan Willem; Weissenhorn, Renate; Sauer, Ursula G

    2015-10-01

    The European Partnership for Alternative Approaches to Animal Testing (EPAA) convened a workshop Knowledge sharing to facilitate regulatory decision-making. Fifty invited participants from the European Commission, national and European agencies and bodies, different industry sectors (chemicals, cosmetics, fragrances, pharmaceuticals, vaccines), and animal protection organizations attended the workshop. Four case studies exemplarily revealed which procedures are in place to obtain regulatory acceptance of new test methods in different sectors. Breakout groups discussed the status quo identifying the following facilitators for regulatory acceptance of alternatives to animal testing: Networking and communication (including cross-sector collaboration, international cooperation and harmonization); involvement of regulatory agencies from the initial stages of test method development on; certainty on prerequisites for test method acceptance including the establishment of specific criteria for regulatory acceptance. Data sharing and intellectual property issues affect many aspects of test method development, validation and regulatory acceptance. In principle, all activities should address replacement, reduction and refinement methods (albeit animal testing is generally prohibited in the cosmetics sector). Provision of financial resources and education support all activities aiming at facilitating the acceptance and use of alternatives to animal testing. Overall, workshop participants recommended building confidence in new methodologies by applying and gaining experience with them. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Medical abortion with mifepristone and home administration of misoprostol up to 63 days' gestation.

    PubMed

    Løkeland, Mette; Iversen, Ole Erik; Engeland, Anders; Økland, Ingrid; Bjørge, Line

    2014-07-01

    To evaluate the acceptability and efficacy of medical abortion at home up to 63 days' gestation without limits on travel distance to a registered institution. Observational prospective study. Haukeland University Hospital between May 2006 and May 2009. A total of 1018 women requesting abortion before 63 days' gestation who chose medical termination with mifepristone and home administration of misoprostol. The women took 200 mg mifepristone under nurse supervision and self-administered 800 μg misoprostol vaginally 36-48 h later at home. All were contacted by phone for follow-up and assessment of bleeding, pain and acceptability. Evacuation rate, pain, bleeding, acceptability, influence of distance on treatment. Median gestational age was 50 (range 35-63) days and 70 (7.1%) of the women lived more than 60 min travel from the clinic. The rate of completed abortion was 93.6% and surgical evacuation was performed in 50 (4.9%) cases. Two women requested treatment on the day of misoprostol use. Moderate to strong pain was experienced by 68.4%, and 74.7% reported moderate to heavy bleeding. Parous women experienced less pain than nulliparous women (odds ratio 0.27; 95% confidence interval 0.19-0.34). In all, 95.1% of the women were satisfied with staying at home. Travel distance did not influence treatment outcome variables. In our experience, home administration of misoprostol is an effective and acceptable method for abortion up to 63 days of gestation and women should be eligible for this treatment option regardless of their travel distance from hospital. © 2014 The Authors. Acta Obstetricia et Gynecologica Scandinavica published by John Wiley & Sons on behalf of Nordic Federation of Societies of Obstetrics and Gynecology.

  4. Cold Aero Performance of a Two-Dimensional Mixer Ejector Nozzle

    NASA Technical Reports Server (NTRS)

    Balan, C.

    2005-01-01

    Since 1986, NASA and the U.S. aerospace industry have been assessing the economic viability and environmental acceptability of a second-generation supersonic civil transport, or High Speed Civil Transport (HSCT). Environmental acceptability in terms of airport community noise and economic viability are critical elements in this endeavor. Development of a propulsion system that satisfies strict airport noise regulations (FAR36 Stage III levels), at acceptable performance and weight, is critical to the success of any HSCT program. Two-dimensional mixer-ejector (2DME) exhaust systems are one approach in achieving this goal. In support of HSCT development, GEAE (GE Aircraft Engines), under contract to the NASA Glenn Research Center, conducted this test program at the NASA Langley 16 ft transonic wind tunnel to evaluate the cold aerodynamic performance aspects of the 2DME exhaust system concept. The effects of SAR (SAR, suppressor area ratio, = mixed-flow area/primary nozzle throat area), MAR (MAR = overall exhaust system exit/mixing-plane area), flap length, CER (suppressor chute expansion ratio), chute alignment, and free stream Mach number were investigated on a 1/11th cold aerodynamic scale model of a 2DME exhaust system.

  5. Radiometric ratio characterization for low-to-mid CPV modules operating in variable irradiance conditions

    NASA Astrophysics Data System (ADS)

    Vorndran, Shelby; Russo, Juan; Zhang, Deming; Gordon, Michael; Kostuk, Raymond

    2012-10-01

    In this work, a concentrating photovoltaic (CPV) design methodology is proposed which aims to maximize system efficiency for a given irradiance condition. In this technique, the acceptance angle of the system is radiometrically matched to the angular spread of the site's average irradiance conditions using a simple geometric ratio. The optical efficiency of CPV systems from flat-plate to high-concentration is plotted at all irradiance conditions. Concentrator systems are measured outdoors in various irradiance conditions to test the methodology. This modeling technique is valuable at the design stage to determine the ideal level of concentration for a CPV module. It requires only two inputs: the acceptance angle profile of the system and the site's average direct and diffuse irradiance fractions. Acceptance angle can be determined by raytracing or testing a fabricated prototype in the lab with a solar simulator. The average irradiance conditions can be found in the Typical Metrological Year (TMY3) database. Additionally, the information gained from this technique can be used to determine tracking tolerance, quantify power loss during an isolated weather event, and do more sophisticated analysis such as I-V curve simulation.

  6. “Gaining or losing”: The importance of the perspective in primary care health services valuation

    PubMed Central

    Ariza-Cardiel, Gloria; Peña-Longobardo, Luz Mª; Polentinos-Castro, Elena; Oliva-Moreno, Juan; Gil-Lacruz, Ana Isabel; Medina-Palomino, Héctor; del Cura-González, Isabel

    2017-01-01

    Rationale and objectives Economic theory classifies an intervention as socially beneficial if the total Willingness to Pay (WTP) of those who gain exceeds the total Willingness to accept (WTA) of those who are harmed. This paper examines the differences in health system users’ valuation of a health care service in primary care setting based on the WTP and WTA perspectives, discussing the impact of personal and service variables, including risk attitudes, on these disparities. Method Six hundred and sixty two subjects who asked for care in health centres in the Region of Madrid (Spain) were interviewed, using the contingent valuation method to estimate WTP and WTA. Patient sociodemographic characteristics, health needs, satisfaction with the service and risk attitude and behaviour under risk (measured by self-reported scales and lottery games respectively) were collected. Generalised Linear Models were used to estimate the association between the explanatory variables and the WTA/WTP ratio. Results We obtained the WTA/WTP ratio for 570 subjects (mean 1.66 CI 95%: 1.53–1.79; median 1, interquartile range 1–2). People with higher education or in high social groups expressed WTA values closest to WTP. The opposite occurred in patients with the greatest health needs or who were born abroad. Self-reported expression of risk aversion appeared also related to increases in the WTA/WTP ratio. Satisfaction with the service evaluated was the most influential factor in the WTA/WTP ratio. Conclusion Health need, difficulty in obtaining substitutes and satisfaction with the service could serve for profiling people averse to loss for health care services in primary care setting. Self-reported expression of risk aversion could also be related to increases in the WTA/WTP ratio. This would mean that these characteristics should be taken into account both in the design and implementation of new healthcare interventions, as in the making decision for disinvestment. PMID:29206847

  7. Synthesis of high aspect ratio ZnO nanowires with an inexpensive handcrafted electrochemical setup

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taheri, Ali, E-mail: at1361@aut.ac.ir, E-mail: atahery@aeoi.org.ir; Saramad, Shahyar; Setayeshi, Saeed

    In this work, high aspect ratio zinc oxide nanowires are synthesized using templated one-step electrodeposition technique. Electrodeposition of the nanowires is done using a handcrafted electronic system. Nuclear track-etched polycarbonate membrane is used as a template to form the high aspect ratio nanowires. The result of X-ray diffraction and scanning electron microscopy shows that nanowires with a good crystallinity and an aspect ratio of more than 30 can be achieved in a suitable condition. The height of electrodeposited nanowires reaches to about 11 μm. Based on the obtained results, high aspect ratio ZnO nanowires can be formed using inexpensive electrodepositionmore » setup with an acceptable quality.« less

  8. Expert opinions on the acceptance of alternative methods in food safety evaluations: Formulating recommendations to increase acceptance of non-animal methods for kinetics.

    PubMed

    Punt, Ans; Bouwmeester, Hans; Schiffelers, Marie-Jeanne W A; Peijnenburg, Ad A C M

    2018-02-01

    Inclusion of alternative methods that replace, reduce, or refine (3R) animal testing within regulatory safety evaluations of chemicals generally faces many hurdles. The goal of the current work is to i) collect responses from key stakeholders involved in food safety evaluations on what they consider the most relevant factors that influence the acceptance and use of 3R methods and to ii) use these responses to formulate activities needed to increase the acceptance and use of 3R methods, particularly for kinetics. The stakeholders were contacted by e-mail for their opinions, asking the respondents to write down three barriers and/or drivers and scoring these by distributing 5 points over the three factors. The main barriers that obtained the highest aggregated scores were i) uncertain predictability 3R methods/lack of validation, ii) insufficient guidance regulators/industry and iii) insufficient harmonization of legislation. The major driver identified was the possibility of 3R methods to provide more mechanistic information. Based on the results, recommendations are given to enhance the acceptance and application of 3R toxicokinetic methods in food safety evaluations. These include steering of regulatory data requirements as well as creating (funding) opportunities for development and validation of alternative methods for kinetics and development of guidances. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Parents Who Decline HPV Vaccination: Who Later Accepts and Why?

    PubMed

    Kornides, Melanie L; McRee, Annie-Laurie; Gilkey, Melissa B

    2018-03-01

    Parental declination contributes to low human papillomavirus (HPV) vaccination coverage among US adolescents, resulting in missed opportunities for cancer prevention. We sought to characterize parents' acceptance of HPV vaccination after declination ("secondary acceptance"). In September 2016, we conducted an online survey with a national sample of parents of children ages 11 to 17 years. For those who reported having ever declined HPV vaccination for their children (n = 494), our survey assessed whether they accepted the vaccine at a subsequent visit. We used multivariable logistic regression to assess correlates of secondary acceptance. Overall, 45% of parents reported secondary acceptance of HPV vaccination, and an additional 24% intended to vaccinate in the next 12 months. In multivariable analyses, secondary acceptance was associated with receiving follow-up counseling about HPV vaccination from a health care provider (odds ratio, 2.16; 95% confidence interval, 1.42-3.28). However, only 53% of parents overall reported receiving such counseling. Secondary acceptance was also associated with receiving a higher quality HPV vaccine recommendation from a provider during the initial discussion and greater satisfaction with provider communication, as well as higher vaccination confidence. Among the reasons for secondary acceptance, parents most commonly reported the child getting older (45%), learning more about HPV vaccine (34%), and receiving a provider recommendation (33%). Our findings suggest secondary acceptance of HPV vaccination is common, with more than two-thirds of parents in this national sample accepting or intending to accept HPV vaccination after declination. Providers should seek to motivate secondary acceptance by delivering repeated, high-quality recommendations for HPV vaccination. Copyright © 2017 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  10. Angular and Seasonal Variation of Spectral Surface Reflectance Ratios: Implications for the Remote Sensing of Aerosol over Land

    NASA Technical Reports Server (NTRS)

    Remer, L. A.; Wald, A. E.; Kaufman, Y. J.

    1999-01-01

    We obtain valuable information on the angular and seasonal variability of surface reflectance using a hand-held spectrometer from a light aircraft. The data is used to test a procedure that allows us to estimate visible surface reflectance from the longer wavelength 2.1 micrometer channel (mid-IR). Estimating or avoiding surface reflectance in the visible is a vital first step in most algorithms that retrieve aerosol optical thickness over land targets. The data indicate that specular reflection found when viewing targets from the forward direction can severely corrupt the relationships between the visible and 2.1 micrometer reflectance that were derived from nadir data. There is a month by month variation in the ratios between the visible and the mid-IR, weakly correlated to the Normalized Difference Vegetation Index (NDVI). If specular reflection is not avoided, the errors resulting from estimating surface reflectance from the mid-IR exceed the acceptable limit of DELTA-rho approximately 0.01 in roughly 40% of the cases, using the current algorithm. This is reduced to 25% of the cases if specular reflection is avoided. An alternative method that uses path radiance rather than explicitly estimating visible surface reflectance results in similar errors. The two methods have different strengths and weaknesses that require further study.

  11. A modified 3D algorithm for road traffic noise attenuation calculations in large urban areas.

    PubMed

    Wang, Haibo; Cai, Ming; Yao, Yifan

    2017-07-01

    The primary objective of this study is the development and application of a 3D road traffic noise attenuation calculation algorithm. First, the traditional empirical method does not address problems caused by non-direct occlusion by buildings and the different building heights. In contrast, this study considers the volume ratio of the buildings and the area ratio of the projection of buildings adjacent to the road. The influence of the ground affection is analyzed. The insertion loss due to barriers (infinite length and finite barriers) is also synthesized in the algorithm. Second, the impact of different road segmentation is analyzed. Through the case of Pearl River New Town, it is recommended that 5° is the most appropriate scanning angle as the computational time is acceptable and the average error is approximately 3.1 dB. In addition, the algorithm requires only 1/17 of the time that the beam tracking method requires at the cost of more imprecise calculation results. Finally, the noise calculation for a large urban area with a high density of buildings shows the feasibility of the 3D noise attenuation calculation algorithm. The algorithm is expected to be applied in projects requiring large area noise simulations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Cleaning verification: Exploring the effect of the cleanliness of stainless steel surface on sample recovery.

    PubMed

    Haidar Ahmad, Imad A; Tam, James; Li, Xue; Duffield, William; Tarara, Thomas; Blasko, Andrei

    2017-02-05

    The parameters affecting the recovery of pharmaceutical residues from the surface of stainless steel coupons for quantitative cleaning verification method development have been studied, including active pharmaceutical ingredient (API) level, spiking procedure, API/excipient ratio, analyst-to-analyst variability, inter-day variability, and cleaning procedure of the coupons. The lack of a well-defined procedure that consistently cleaned coupon surface was identified as the major contributor to low and variable recoveries. Assessment of acid, base, and oxidant washes, as well as the order of treatment, showed that a base-water-acid-water-oxidizer-water wash procedure resulted in consistent, accurate spiked recovery (>90%) and reproducible results (S rel ≤4%). By applying this cleaning procedure to the previously used coupons that failed the cleaning acceptance criteria, multiple analysts were able to obtain consistent recoveries from day-to-day for different APIs, and API/excipient ratios at various spike levels. We successfully applied our approach for cleaning verification of small molecules (MW<1000Da) as well as large biomolecules (MW up to 50,000Da). Method robustness was greatly influenced by the sample preparation procedure, especially for analyses using total organic carbon (TOC) determination. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Commissioning and initial acceptance tests for a commercial convolution dose calculation algorithm for radiotherapy treatment planning in comparison with Monte Carlo simulation and measurement

    PubMed Central

    Moradi, Farhad; Mahdavi, Seyed Rabi; Mostaar, Ahmad; Motamedi, Mohsen

    2012-01-01

    In this study the commissioning of a dose calculation algorithm in a currently used treatment planning system was performed and the calculation accuracy of two available methods in the treatment planning system i.e., collapsed cone convolution (CCC) and equivalent tissue air ratio (ETAR) was verified in tissue heterogeneities. For this purpose an inhomogeneous phantom (IMRT thorax phantom) was used and dose curves obtained by the TPS (treatment planning system) were compared with experimental measurements and Monte Carlo (MCNP code) simulation. Dose measurements were performed by using EDR2 radiographic films within the phantom. Dose difference (DD) between experimental results and two calculation methods was obtained. Results indicate maximum difference of 12% in the lung and 3% in the bone tissue of the phantom between two methods and the CCC algorithm shows more accurate depth dose curves in tissue heterogeneities. Simulation results show the accurate dose estimation by MCNP4C in soft tissue region of the phantom and also better results than ETAR method in bone and lung tissues. PMID:22973081

  14. Bayesian Parameter Estimation for Heavy-Duty Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Eric; Konan, Arnaud; Duran, Adam

    2017-03-28

    Accurate vehicle parameters are valuable for design, modeling, and reporting. Estimating vehicle parameters can be a very time-consuming process requiring tightly-controlled experimentation. This work describes a method to estimate vehicle parameters such as mass, coefficient of drag/frontal area, and rolling resistance using data logged during standard vehicle operation. The method uses Monte Carlo to generate parameter sets which is fed to a variant of the road load equation. Modeled road load is then compared to measured load to evaluate the probability of the parameter set. Acceptance of a proposed parameter set is determined using the probability ratio to the currentmore » state, so that the chain history will give a distribution of parameter sets. Compared to a single value, a distribution of possible values provides information on the quality of estimates and the range of possible parameter values. The method is demonstrated by estimating dynamometer parameters. Results confirm the method's ability to estimate reasonable parameter sets, and indicates an opportunity to increase the certainty of estimates through careful selection or generation of the test drive cycle.« less

  15. Rapid analysis of ultraviolet filters using dispersive liquid-liquid microextraction coupled to headspace gas chromatography and mass spectrometry.

    PubMed

    Pierson, Stephen A; Trujillo-Rodríguez, María J; Anderson, Jared L

    2018-05-29

    An ionic-liquid-based in situ dispersive liquid-liquid microextraction method coupled to headspace gas chromatography and mass spectrometry was developed for the rapid analysis of ultraviolet filters. The chemical structures of five ionic liquids were specifically designed to incorporate various functional groups for the favorable extraction of the target analytes. Extraction parameters including ionic liquid mass, molar ratio of ionic liquid to metathesis reagent, vortex time, ionic strength, pH, and total sample volume were studied and optimized. The effect of the headspace temperature and volume during the headspace sampling step was also evaluated to increase the sensitivity of the method. The optimized procedure is fast as it only required ∼7-10 min per extraction and allowed for multiple extractions to be performed simultaneously. In addition, the method exhibited high precision, good linearity, and low limits of detection for six ultraviolet filters in aqueous samples. The developed method was applied to both pool and lake water samples attaining acceptable relative recovery values. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. 40 CFR 63.90 - Program overview.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... “proven technology” (generally accepted by the scientific community as equivalent or better) that is... enforceable test method involving “proven technology” (generally accepted by the scientific community as... interest; and (3) “Combining” a federally required method with another proven method for application to...

  17. 40 CFR 63.90 - Program overview.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... “proven technology” (generally accepted by the scientific community as equivalent or better) that is... enforceable test method involving “proven technology” (generally accepted by the scientific community as... interest; and (3) “Combining” a federally required method with another proven method for application to...

  18. Influences of Normalization Method on Biomarker Discovery in Gas Chromatography-Mass Spectrometry-Based Untargeted Metabolomics: What Should Be Considered?

    PubMed

    Chen, Jiaqing; Zhang, Pei; Lv, Mengying; Guo, Huimin; Huang, Yin; Zhang, Zunjian; Xu, Fengguo

    2017-05-16

    Data reduction techniques in gas chromatography-mass spectrometry-based untargeted metabolomics has made the following workflow of data analysis more lucid. However, the normalization process still perplexes researchers, and its effects are always ignored. In order to reveal the influences of normalization method, five representative normalization methods (mass spectrometry total useful signal, median, probabilistic quotient normalization, remove unwanted variation-random, and systematic ratio normalization) were compared in three real data sets with different types. First, data reduction techniques were used to refine the original data. Then, quality control samples and relative log abundance plots were utilized to evaluate the unwanted variations and the efficiencies of normalization process. Furthermore, the potential biomarkers which were screened out by the Mann-Whitney U test, receiver operating characteristic curve analysis, random forest, and feature selection algorithm Boruta in different normalized data sets were compared. The results indicated the determination of the normalization method was difficult because the commonly accepted rules were easy to fulfill but different normalization methods had unforeseen influences on both the kind and number of potential biomarkers. Lastly, an integrated strategy for normalization method selection was recommended.

  19. Retinal injury from simultaneous exposure to 532-nm and 860-nm laser irradiation

    NASA Astrophysics Data System (ADS)

    Schuster, Kurt; Roach, William P.; Polhamus, Garrett; Notabartolo, John; DiCarlo, Cheryl; Stockton, Kevin; Stolarski, David; Carothers, Val; Rockwell, Benjamin A.; Cain, Clarence

    2004-07-01

    To properly assess the retinal hazards from several lasers using multiple wavelengths, the retinal effects of 10-second laser irradiation from 532 and 860 nm were determined in non-human primates for several different power combinations of these wavelengths. A total of 12 eyes were exposed using four different ratios of power levels to determine the contribution to the damage levels from each wavelength. The data are compared to the calculations resulting from use of the currently accepted method of predicting hazards from simultaneous laser. The ANSI-Z136 - 2000 standard was used to calculate the combined maximum permissible exposure (MPE) and for comparison with the measured visible lesion thresholds, i.e., ED50s.

  20. Older Adults' Acceptance of Activity Trackers

    PubMed Central

    Preusse, Kimberly C.; Mitzner, Tracy L.; Fausset, Cara Bailey; Rogers, Wendy A.

    2016-01-01

    Objective To assess the usability and acceptance of activity tracking technologies by older adults. Method First in our multi-method approach, we conducted heuristic evaluations of two activity trackers that revealed potential usability barriers to acceptance. Next, questionnaires and interviews were administered to 16 older adults (Mage=70, SDage=3.09, rangeage= 65-75) before and after a 28-day field study to understand facilitators and additional barriers to acceptance. These measurements were supplemented with diary and usage data and assessed if and why users overcame usability issues. Results The heuristic evaluation revealed usability barriers in System Status Visibility; Error Prevention; and Consistency and Standards. The field study revealed additional barriers (e.g., accuracy, format), and acceptance-facilitators (e.g., goal-tracking, usefulness, encouragement). Discussion The acceptance of wellness management technologies, such as activity trackers, may be increased by addressing acceptance-barriers during deployment (e.g., providing tutorials on features that were challenging, communicating usefulness). PMID:26753803

  1. Modelling acceptance of sunlight in high and low photovoltaic concentration

    NASA Astrophysics Data System (ADS)

    Leutz, Ralf

    2014-09-01

    A simple model incorporating linear radiation characteristics, along with the optical trains and geometrical concentration ratios of solar concentrators is presented with performance examples for optical trains of HCPV, LCPV and benchmark flat-plate PV.

  2. Downlinks for DBS - Design and engineering considerations

    NASA Astrophysics Data System (ADS)

    Blecker, M.; Martin, E. R.

    1985-01-01

    The subsystem interrelationships and design parameters choice procedures for a DBS downlink design are discussed from a business decisions point of view. The image quality is determined by customer satisfaction, which is translated to a required carrier/noise (C/N) ratio. The C/N ratio defines acceptable levels of signal fading, a subjective value which is modified by the demographics of the service area. Increasing the satellite on-board transmitting power to meet acceptable broadcast reliability places burdens on the start-up capitalization of the business. Larger receiving antennas in rural areas ameliorates some of the power requirements. The dish size, however, affects the labor costs of installation, but must be kept small enough to be used in heavily populated areas. The satellites must be built, as far as is possible, from off-the-shelf components to keep costs down. Design selections for a sample complete system are listed.

  3. Extraction, scrub, and strip test results for the solvent transfer to salt waste processing facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T.

    The Savannah River National Laboratory (SRNL) prepared approximately 240 gallons of Caustic-Side Solvent Extraction (CSSX) solvent for use at the Salt Waste Processing Facility (SWPF). An Extraction, Scrub, and Strip (ESS) test was performed on a sample of the prepared solvent using a salt solution prepared by Parsons to determine cesium distribution ratios (D(Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams. This data will be used by Parsons to help qualify the solvent for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations.more » The extraction D(Cs) measured 15.5, exceeding the required value of 8. This value is consistent with results from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges.« less

  4. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    NASA Technical Reports Server (NTRS)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  5. A Generalized Pivotal Quantity Approach to Analytical Method Validation Based on Total Error.

    PubMed

    Yang, Harry; Zhang, Jianchun

    2015-01-01

    The primary purpose of method validation is to demonstrate that the method is fit for its intended use. Traditionally, an analytical method is deemed valid if its performance characteristics such as accuracy and precision are shown to meet prespecified acceptance criteria. However, these acceptance criteria are not directly related to the method's intended purpose, which is usually a gurantee that a high percentage of the test results of future samples will be close to their true values. Alternate "fit for purpose" acceptance criteria based on the concept of total error have been increasingly used. Such criteria allow for assessing method validity, taking into account the relationship between accuracy and precision. Although several statistical test methods have been proposed in literature to test the "fit for purpose" hypothesis, the majority of the methods are not designed to protect the risk of accepting unsuitable methods, thus having the potential to cause uncontrolled consumer's risk. In this paper, we propose a test method based on generalized pivotal quantity inference. Through simulation studies, the performance of the method is compared to five existing approaches. The results show that both the new method and the method based on β-content tolerance interval with a confidence level of 90%, hereafter referred to as the β-content (0.9) method, control Type I error and thus consumer's risk, while the other existing methods do not. It is further demonstrated that the generalized pivotal quantity method is less conservative than the β-content (0.9) method when the analytical methods are biased, whereas it is more conservative when the analytical methods are unbiased. Therefore, selection of either the generalized pivotal quantity or β-content (0.9) method for an analytical method validation depends on the accuracy of the analytical method. It is also shown that the generalized pivotal quantity method has better asymptotic properties than all of the current methods. Analytical methods are often used to ensure safety, efficacy, and quality of medicinal products. According to government regulations and regulatory guidelines, these methods need to be validated through well-designed studies to minimize the risk of accepting unsuitable methods. This article describes a novel statistical test for analytical method validation, which provides better protection for the risk of accepting unsuitable analytical methods. © PDA, Inc. 2015.

  6. Parental acceptance of HPV vaccines in Chiang Mai, Thailand.

    PubMed

    Juntasopeepun, Phanida; Thana, Kanjana

    2018-06-01

    To identify variables associated with the acceptance of HPV vaccination among Thai parents/primary caregivers. The present prospective cross-sectional study recruited the parents/caregivers of female adolescents aged 12-18 years from schools in Chiang Mai, Thailand, between January 1 and February 29, 2016. A four-part questionnaire was distributed to assess demographics, HPV vaccine acceptance, knowledge, and beliefs toward HPV and cervical cancer. Predictors of HPV vaccine acceptance were determined by logistic regression analysis. The study enrolled 331 parents; more than half (195 [61.1%]) had heard of HPV vaccines. Their knowledge related to HPV and cervical cancer was moderate. A majority of parents (266/313 [85.0%]) indicated they would accept HPV vaccination if the costs were subsidized by the government. Acceptance of HPV vaccines was associated with perceived benefits of HPV vaccination (odds ratio [OR] 1.49; 95% confidence interval [CI] 1.18-1.88), perceived susceptibility to disease (OR 1.42; 95% CI 1.11-1.81), and household income (OR 1.35; 95% CI 1.02-1.78). Parental beliefs have an important role in their acceptance to vaccinate their daughters. These potentially modifiable beliefs offer strategies for future interventions designed to increase uptake for future HPV vaccination campaigns. © 2018 International Federation of Gynecology and Obstetrics.

  7. Memory-based snowdrift game on a square lattice

    NASA Astrophysics Data System (ADS)

    Shu, Feng; Liu, Xingwen; Fang, Kai; Chen, Hao

    2018-04-01

    Spatial reciprocity is an effective way widely accepted to facilitate cooperation. In the case of snowdrift game, some researches showed that spatial reciprocity inhibits cooperation for a very wide range of cost-to-benefit ratio r. However, some other researches found that based on the spatial reciprocity, a wider range of r is helpful to achieve a high cooperation level. Thus, how to enlarge the range of r for the purpose of promoting cooperation becomes a hot topic recently. This paper proposes a new memory-based method, in which each individual compares with its own previous payoffs to find out the maximal one as virtual payoff and then randomly compares with one of its neighbours to obtain the optimal strategy according to the given updating rules. It shows the positive effect of spatial reciprocity in the context of memory. Specifically, in this situation, not only the lower ratio can appear a high cooperation level, but also the larger ratio r can emerge a high cooperation level. That is, an expected cooperation level can be achieved simultaneously for small and large r. Furthermore, the scenarios of both constant-size memory and size-varying memory are investigated. An interesting phenomenon is discovered that the cooperation level drops down gradually as the memory size increases.

  8. Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector

    NASA Astrophysics Data System (ADS)

    Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Brás, P.; Byram, D.; Carmona-Benitez, M. C.; Chan, C.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; Dobi, A.; Druszkiewicz, E.; Edwards, B. N.; Fallon, S. R.; Fan, A.; Fiorucci, S.; Gaitskell, R. J.; Genovesi, J.; Ghag, C.; Gilchriese, M. G. D.; Hall, C. R.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Lenardo, B. G.; Lesko, K. T.; Liao, J.; Lindote, A.; Lopes, M. I.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D.-M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Rhyne, C.; Shaw, S.; Shutt, T. A.; Silva, C.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W. C.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Utku, U.; Uvarov, S.; Velan, V.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Xu, J.; Yazdani, K.; Young, S. K.; Zhang, C.; LUX Collaboration

    2018-06-01

    Weakly interacting massive particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection chambers. We present a measurement of the scintillation timing characteristics of liquid xenon in the LUX dark matter detector and develop a pulse shape discriminant to be used for particle identification. To accurately measure the timing characteristics, we develop a template-fitting method to reconstruct the detection times of photons. Analyzing calibration data collected during the 2013-2016 LUX WIMP search, we provide a new measurement of the singlet-to-triplet scintillation ratio for electron recoils (ER) below 46 keV, and we make, to our knowledge, a first-ever measurement of the NR singlet-to-triplet ratio at recoil energies below 74 keV. We exploit the difference of the photon time spectra for NR and ER events by using a prompt fraction discrimination parameter, which is optimized using calibration data to have the least number of ER events that occur in a 50% NR acceptance region. We then demonstrate how this discriminant can be used in conjunction with the charge-to-light discrimination to possibly improve the signal-to-noise ratio for nuclear recoils.

  9. Basic Studies of Gases for Fast Switches.

    DTIC Science & Technology

    1985-01-01

    be found from WAr W unknown ATAr ATunknown By measuring the AT for argon and the "unknown’ gas mixture [i.e., the time required to charge C to a given...the ratio ATAr W Ar ATN WN2 2 2 We have found the ratio to be within -.0.2% of the generally accepted ratio of W Arand W N2 IONIZAION________GUAR...Bull. Acad. Sc1. USSR Div. Chem. Sci., English Transl. 28, 2227 (1979). 18T. F. O’Malley, Phys. Rev. 155, 59 (1967); W. R. Henderson, W. L. Fi and R. T

  10. Acceptability and adherence: findings from a Phase II study of a candidate vaginal microbicide, 'Praneem polyherbal tablet', in Pune, India.

    PubMed

    Joglekar, N S; Joshi, S N; Deshpande, S S; Parkhe, A N; Katti, U R; Mehendale, S M

    2010-06-01

    Acceptability and adherence in clinical trials of microbicides may possibly predict their acceptance by the community. In this study, we investigated the acceptability and adherence of Praneem polyherbal tablet, a candidate microbicide, among 100 HIV-uninfected participants of a Phase II randomised, double-blind, placebo-controlled trial in Pune, India, conducted between June 2004 and February 2006 involving 6 months of coitally-dependent product use. The relationship between five acceptability domains and adherence to product use during the study period was explored. Acceptability and adherence were assessed among 95 study participants completing all study follow-ups. One hundred percent adherence (product use during each sex act for the study period) was reported by 67 participants (70.5%). The majority of participants reported acceptability towards all product characteristics. Product odour was reported to be a concern both in the placebo and Praneem arms. Participants from the Praneem arm [adjusted odds ratio (AOR)=3.8; 95% CI 1.4-10.8] and participants reporting lower acceptability for experience of product use during the sex act (AOR=4.2; 95% CI 1.0-17.3) were more likely to have partial adherence. In conclusion, the study product was acceptable to the majority of participants. However, barriers to adherence attributable to undesirable sexual experiences need to be addressed. 2010 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

  11. Specimen rejection in laboratory medicine: Necessary for patient safety?

    PubMed Central

    Dikmen, Zeliha Gunnur; Pinar, Asli; Akbiyik, Filiz

    2015-01-01

    Introduction The emergency laboratory in Hacettepe University Hospitals receives specimens from emergency departments (EDs), inpatient services and intensive care units (ICUs). The samples are accepted according to the rejection criteria of the laboratory. In this study, we aimed to evaluate the sample rejection ratios according to the types of pre-preanalytical errors and collection areas. Materials and methods The samples sent to the emergency laboratory were recorded during 12 months between January to December, 2013 in which 453,171 samples were received and 27,067 specimens were rejected. Results Rejection ratios was 2.5% for biochemistry tests, 3.2% for complete blood count (CBC), 9.8% for blood gases, 9.2% for urine analysis, 13.3% for coagulation tests, 12.8% for therapeutic drug monitoring, 3.5% for cardiac markers and 12% for hormone tests. The most frequent rejection reasons were fibrin clots (28%) and inadequate volume (9%) for biochemical tests. Clotted samples (35%) and inadequate volume (13%) were the major causes for coagulation tests, blood gas analyses and CBC. The ratio of rejected specimens was higher in the EDs (40%) compared to ICUs (30%) and inpatient services (28%). The highest rejection ratio was observed in neurology ICU (14%) among the ICUs and internal medicine inpatient service (10%) within inpatient clinics. Conclusions We detected an overall specimen rejection rate of 6% in emergency laboratory. By documentation of rejected samples and periodic training of healthcare personnel, we expect to decrease sample rejection ratios below 2%, improve total quality management of the emergency laboratory and promote patient safety. PMID:26527231

  12. A study of the user's perception of economic value in nursing visits to primary care by the method of contingent valuation

    PubMed Central

    2011-01-01

    Background The identification of the attribution of economic value that users of a health system assign to a health service could be useful in planning these services. The method of contingent valuation can provide information about the user's perception of value in monetary terms, and therefore comparable between services of a very different nature. This study attempts to extract the economic value that the subject, user of primary care nursing services in a public health system, attributes to this service by the method of contingent valuation, based on the perspectives of Willingness to Pay (WTP) and Willingness to Accept [Compensation] (WTA). Methods/Design This is an economic study with a transversal design. The contingent valuation method will be used to estimate the user's willingness to pay (WTP) for the care received from the primary care nurse and the willingness to accept [compensation] (WTA), were this service eliminated. A survey that meets the requisites of the contingent valuation method will be constructed and pilot-tested. Subsequently, 600 interviews will be performed with subjects chosen by systematic randomized sampling from among those who visit nursing at twenty health centers with different socioeconomic characteristics in the Community of Madrid. The characteristics of the subject and of the care received that can explain the variations in WTP, WTA and in the WTP/WTA ratio expressed will be studied. A theoretical validation of contingent valuation will be performed constructing two explanatory multivariate mixed models in which the dependent variable will be WTP, and the WTP/WTA relationship, respectively. Discussion The identification of the attribution of economic value to a health service that does not have a direct price at the time of use, such as a visit to primary care nursing, and the definition of a profile of "loss aversion" in reference to the service evaluated, can be relevant elements in planning, enabling incorporating patient preferences to health policy decision-making. PMID:21967306

  13. Neurogenic bowel dysfunction (NBD) translation and linguistic validation to classical Arabic.

    PubMed

    Mallek, A; Elleuch, M H; Ghroubi, S

    2016-09-01

    To translate and linguistically validate in classical Arabic; the French version of the neurogenic bowel dysfunction (NBD). Arabic translation of the NBD score was obtained by the "forward translation/backword translation" method. Patients with multiple sclerosis (MS) and spinal cord injury were included. Evaluation of intestinal and anorectal disorders was conducted by the self-administered questionnaire NBD, which was filled twice two weeks apart. An item-by-item analysis was made. The feasibility, acceptability, internal consistency using Cronbach's alpha, and test-retest repeatability by non-parametric Spearman correlation were studied. Twenty-three patients with colorectal disorders secondary to neurological disease were included, the average age was 40.79±9.16years and the sex-ratio was 1.85. The questionnaire was feasible and acceptable, no items were excluded. The spearman correlation was of 0.842. Internal consistency was judged good through the Cronbach's alpha was of 0.896. The Arabic version of NBD was reproducible and construct validity was satisfactory. The study of its responsiveness to change with a larger number of patients will be the subject of further work. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. Incisors’ proportions in smile esthetics

    PubMed Central

    Alsulaimani, Fahad F; Batwa, Waeil

    2013-01-01

    Aims: To determine whether alteration of the maxillary central and lateral incisors’ length and width, respectively, would affect perceived smile esthetics and to validate the most esthetic length and width, respectively, for the central and lateral incisors. Materials and Methods: Photographic manipulation was undertaken to produce two sets of photographs, each set of four photographs showing the altered width of the lateral incisor and length of the central length. The eight produced photographs were assessed by laypeople, dentists and orthodontists. Results: Alteration in the incisors’ proportion affected the relative smile attractiveness for laypeople (n=124), dentists (n=115) and orthodontists (n=68); dentists and orthodontists did not accept lateral width reduction of more than 0.5 mm (P<0.01), which suggests that the lateral to central incisor width ratio ranges from 54% to 62%. However, laypeople did not accept lateral width reduction of more than 1 mm (P<0.01), widening the range to be from 48% to 62%. All groups had zero tolerance for changes in central crown length (P<0.01). Conclusion: All participants recognized that the central incisors’ length changes. For lateral incisors, laypeople were more tolerant than dentists and orthodontists. This suggests that changing incisors’ proportions affects the relative smile attractiveness. PMID:24987650

  15. Do water-limiting conditions predispose Norway spruce to bark beetle attack?

    PubMed Central

    Netherer, Sigrid; Matthews, Bradley; Katzensteiner, Klaus; Blackwell, Emma; Henschke, Patrick; Hietz, Peter; Pennerstorfer, Josef; Rosner, Sabine; Kikuta, Silvia; Schume, Helmut; Schopf, Axel

    2015-01-01

    Drought is considered to enhance susceptibility of Norway spruce (Picea abies) to infestations by the Eurasian spruce bark beetle (Ips typographus, Coleoptera: Curculionidae), although empirical evidence is scarce. We studied the impact of experimentally induced drought on tree water status and constitutive resin flow, and how physiological stress affects host acceptance and resistance. We established rain-out shelters to induce both severe (two full-cover plots) and moderate (two semi-cover plots) drought stress. In total, 18 sample trees, which were divided equally between the above treatment plots and two control plots, were investigated. Infestation was controlled experimentally using a novel ‘attack box’ method. Treatments influenced the ratios of successful and defended attacks, but predisposition of trees to infestation appeared to be mainly driven by variations in stress status of the individual trees over time. With increasingly negative twig water potentials and decreasing resin exudation, the defence capability of the spruce trees decreased. We provide empirical evidence that water-limiting conditions impair Norway spruce resistance to bark beetle attack. Yet, at the same time our data point to reduced host acceptance byI. typographus with more extreme drought stress, indicated by strongly negative pre-dawn twig water potentials. PMID:25417785

  16. Quantification of metabotropic glutamate subtype 5 receptors in the brain by an equilibrium method using 18F-SP203.

    PubMed

    Kimura, Yasuyuki; Siméon, Fabrice G; Zoghbi, Sami S; Zhang, Yi; Hatazawa, Jun; Pike, Victor W; Innis, Robert B; Fujita, Masahiro

    2012-02-01

    A new PET ligand, 3-fluoro-5-(2-(2-(18)F-(fluoromethyl)-thiazol-4-yl)ethynyl)benzonitrile (18F-SP203) can quantify metabotropic glutamate subtype 5 receptors (mGluR5) in human brain by a bolus injection and kinetic modeling. As an alternative approach to a bolus injection, binding can simply be measured as a ratio of tissue to metabolite-corrected plasma at a single time point under equilibrium conditions achieved by administering the radioligand with a bolus injection followed by a constant infusion. The purpose of this study was to validate the equilibrium method as an alternative to the standard kinetic method for measuring 18F-SP203 binding in the brain. Nine healthy subjects were injected with 18F-SP203 using a bolus plus constant infusion for 300 min. A single ratio of bolus-to-constant infusion (the activity of bolus equaled to that of infusion over 219 min) was applied to all subjects to achieve equilibrium in approximately 120 min. As a measure of ligand binding, we compared total distribution volume (VT) calculated by the equilibrium and kinetic methods in each scan. The equilibrium method calculated VT by the ratio of radioactivity in the brain to the concentration of 18F-SP203 in arterial plasma at 120 min, and the kinetic method calculated VT by a two-tissue compartment model using brain and plasma dynamic data from 0 to 120 min. VT obtained via the equilibrium method was highly correlated with VT obtained via kinetic modeling. Inter-subject variability of VT obtained via the equilibrium method was slightly smaller than VT obtained via the kinetic method. VT obtained via the equilibrium method was ~10% higher than VT obtained via the kinetic method, indicating a small difference between the measurements. Taken together, the results of this study show that using the equilibrium method is an acceptable alternative to the standard kinetic method when using 18F-SP203 to measure mGluR5. Although small differences in the measurements obtained via the equilibrium and kinetic methods exist, both methods consistently measured mGluR5 as indicated by the highly correlated VT values; the equilibrium method was slightly more precise, as indirectly measured by the smaller coefficient of variability across subjects. In addition, when using 18F-SP203, the equilibrium method is more efficient because it requires much less data. Copyright © 2011. Published by Elsevier Inc.

  17. 17 CFR 162.8 - Acceptable delivery methods of opt-out notices.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... COMMISSION PROTECTION OF CONSUMER INFORMATION UNDER THE FAIR CREDIT REPORTING ACT Business Affiliate Marketing Rules § 162.8 Acceptable delivery methods of opt-out notices. (a) In general. The opt-out notice...

  18. 17 CFR 162.8 - Acceptable delivery methods of opt-out notices.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... COMMISSION PROTECTION OF CONSUMER INFORMATION UNDER THE FAIR CREDIT REPORTING ACT Business Affiliate Marketing Rules § 162.8 Acceptable delivery methods of opt-out notices. (a) In general. The opt-out notice...

  19. No-reference multiscale blur detection tool for content based image retrieval

    NASA Astrophysics Data System (ADS)

    Ezekiel, Soundararajan; Stocker, Russell; Harrity, Kyle; Alford, Mark; Ferris, David; Blasch, Erik; Gorniak, Mark

    2014-06-01

    In recent years, digital cameras have been widely used for image capturing. These devices are equipped in cell phones, laptops, tablets, webcams, etc. Image quality is an important component of digital image analysis. To assess image quality for these mobile products, a standard image is required as a reference image. In this case, Root Mean Square Error and Peak Signal to Noise Ratio can be used to measure the quality of the images. However, these methods are not possible if there is no reference image. In our approach, a discrete-wavelet transformation is applied to the blurred image, which decomposes into the approximate image and three detail sub-images, namely horizontal, vertical, and diagonal images. We then focus on noise-measuring the detail images and blur-measuring the approximate image to assess the image quality. We then compute noise mean and noise ratio from the detail images, and blur mean and blur ratio from the approximate image. The Multi-scale Blur Detection (MBD) metric provides both an assessment of the noise and blur content. These values are weighted based on a linear regression against full-reference y values. From these statistics, we can compare to normal useful image statistics for image quality without needing a reference image. We then test the validity of our obtained weights by R2 analysis as well as using them to estimate image quality of an image with a known quality measure. The result shows that our method provides acceptable results for images containing low to mid noise levels and blur content.

  20. A new method for correlation analysis of compositional (environmental) data - a worked example.

    PubMed

    Reimann, C; Filzmoser, P; Hron, K; Kynčlová, P; Garrett, R G

    2017-12-31

    Most data in environmental sciences and geochemistry are compositional. Already the unit used to report the data (e.g., μg/l, mg/kg, wt%) implies that the analytical results for each element are not free to vary independently of the other measured variables. This is often neglected in statistical analysis, where a simple log-transformation of the single variables is insufficient to put the data into an acceptable geometry. This is also important for bivariate data analysis and for correlation analysis, for which the data need to be appropriately log-ratio transformed. A new approach based on the isometric log-ratio (ilr) transformation, leading to so-called symmetric coordinates, is presented here. Summarizing the correlations in a heat-map gives a powerful tool for bivariate data analysis. Here an application of the new method using a data set from a regional geochemical mapping project based on soil O and C horizon samples is demonstrated. Differences to 'classical' correlation analysis based on log-transformed data are highlighted. The fact that some expected strong positive correlations appear and remain unchanged even following a log-ratio transformation has probably led to the misconception that the special nature of compositional data can be ignored when working with trace elements. The example dataset is employed to demonstrate that using 'classical' correlation analysis and plotting XY diagrams, scatterplots, based on the original or simply log-transformed data can easily lead to severe misinterpretations of the relationships between elements. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. IS THE IMMUNOCROMATOGRAPHIC FECAL ANTIGEN TEST EFFECTIVE FOR PRIMARY DIAGNOSIS OF HELICOBACTER PYLORI INFECTION IN DYSPEPTIC PATIENTS?

    PubMed

    Dalla Nora, Magali; Hörner, Rosmari; De Carli, Diego Michelon; Rocha, Marta Pires da; Araujo, Amanda Faria de; Fagundes, Renato Borges

    2016-01-01

    The diagnosis of H. pylori infection can be performed by non-invasive and invasive methods.The identification through a fecal antigen test is a non-invasive, simple, and relatively inexpensive test. To determine the diagnostic performance of fecal antigen test in the identification of H. pylori infection. H. pylori antigens were identified in the stools of dyspeptic patients undergoing upper gastrointestinal endoscopy. For the identification of H. pylori antigen, we use ImmunoCard STAT! HpSA with immunochromatography technique. Histopathology plus urease test were the gold standard. We studied 163 patients, 51% male, mean age of 56.7± 8.5years. H. pylori infection was present in 49%. Fecal test presented: sensitivity 67.5% (CI95% 60.6-72.9); specificity 85.5% (CI95% 78.9-90.7); positive predictive value 81.8% (CI95% 73.4-88.4) and negative predictive value 73,2% (CI95% 67.5-77.6); Positive likelihood ratio was 4.7 (CI95% 2.9-7.9) and Negative Likelihood Ratio 0.4 (CI95% 0.3-0.5). The prevalence odds ratio for a positive test was 12.3 (CI95% 5.7-26.3).The index kappa between FAT and histology/urease test was 0.53 (CI95% 0.39-0.64). Immunochromatographic FAT is less expensive than the other methods and readily accepted by the patients but its diagnostic performance does not recommend its use in the primary diagnosis, when the patient may have an active infection.

  2. The promises and limitations of female-initiated methods of HIV/STI protection.

    PubMed

    Mantell, Joanne E; Dworkin, Shari L; Exner, Theresa M; Hoffman, Susie; Smit, Jenni A; Susser, Ida

    2006-10-01

    New methods are now available, and others are being developed, that could enable women to take the initiative in preventing sexually transmitted infections. However, attempts to capitalize on "female-controlled" preventive methods thus far have met with limited success. Female-initiated methods were introduced to intervene in the state of gender relations and assist women who are disempowered vis-à-vis their male partners. Paradoxically, however, we underscore that it is the very structure of regional and local gender relations that shapes the acceptability (or lack of acceptability) of these methods. This paper specifically addresses how the structure of gender relations-for better and for worse-shapes the promises and limitations of widespread use and acceptance of female-initiated methods. We draw on examples from around the world to underscore how the regional specificities of gender (in)equality shape the acceptance, negotiation, and use of these methods. Simultaneously, we demonstrate how the introduction and sustained use of methods are shaped by gender relations and offer possibilities for reinforcing or challenging their current state. Based on our analyses, we offer key policy and programmatic recommendations to increase promotion and effective use of women-initiated HIV/STI protection methods for both women and men.

  3. What's in a name? Perceptions of stray and feral cat welfare and control in Aotearoa, New Zealand.

    PubMed

    Farnworth, Mark J; Campbell, Joanna; Adams, Nigel J

    2011-01-01

    New Zealanders (n = 354) rated the acceptability of lethal and nonlethal cat control methods and the importance of conservation and welfare. Lethal control was more acceptable for feral cats than strays; for nonlethal control, the inverse was true. More than concern for the welfare of cats subjected to control, perceived conservation benefits, risk of disease transfer, and companion cat welfare dictated the acceptability of control measures. Similarly, the welfare consideration for groups of cats differed, transitioning from companion (highest) to feral (lowest). Differences in attitudes toward acceptability of control methods were evident. In particular, nonhuman animal professionals ranked lethal control as more acceptable than did nonanimal professionals. Cat caregivers (owners) considered both conservation and welfare issues of greater importance than did nonowners. Owners ranked the acceptability of nonlethal control methods higher for stray cats, but not feral, than did nonowners. This research indicates that the use of the terms stray and feral may have significant impact on cats in New Zealand. There is also a greater consideration of conservation values than of welfare in stray and feral cat control.

  4. Using Financial Information in Continuing Education. Accepted Methods and New Approaches.

    ERIC Educational Resources Information Center

    Matkin, Gary W.

    This book, which is intended as a resource/reference guide for experienced financial managers and course planners, examines accepted methods and new approaches for using financial information in continuing education. The introduction reviews theory and practice, traditional and new methods, planning and organizational management, and technology.…

  5. Applicability of Cameriere's and Drusini's age estimation methods to a sample of Turkish adults.

    PubMed

    Hatice, Boyacioglu Dogru; Nihal, Avcu; Nursel, Akkaya; Humeyra Ozge, Yilanci; Goksuluk, Dincer

    2017-10-01

    The aim of this study was to investigate the applicability of Drusini's and Cameriere's methods to a sample of Turkish people. Panoramic images of 200 individuals were allocated into two groups as study and test groups and examined by two observers. Tooth coronal indexes (TCI), which is the ratio between coronal pulp cavity height and crown height, were calculated in the mandibular first and second premolars and molars. Pulp/tooth area ratios (ARs) were calculated in the maxillary and mandibular canine teeth. Study group measurements were used to derive a regression model. Test group measurements were used to evaluate the accuracy of the regression model. Pearson's correlation coefficients and regression analysis were used. The correlations between TCIs and age were -0.230, -0.301, -0.344 and -0.257 for mandibular first premolar, second premolar, first molar and second molar, respectively. Those for the maxillary canine (MX) and mandibular canine (MN) ARs were -0.716 and -0.514, respectively. The MX ARs were used to build the linear regression model that explained 51.2% of the total variation, with a standard error of 9.23 years. The mean error of the estimates in test group was 8 years and age of 64% of the individuals were estimated with an error of <±10 years which is acceptable in forensic age prediction. The low correlation coefficients between age and TCI indicate that Drusini's method was not applicable to the estimation of age in a Turkish population. Using Cameriere's method, we derived a regression model.

  6. Application of the modified chi-square ratio statistic in a stepwise procedure for cascade impactor equivalence testing.

    PubMed

    Weber, Benjamin; Lee, Sau L; Delvadia, Renishkumar; Lionberger, Robert; Li, Bing V; Tsong, Yi; Hochhaus, Guenther

    2015-03-01

    Equivalence testing of aerodynamic particle size distribution (APSD) through multi-stage cascade impactors (CIs) is important for establishing bioequivalence of orally inhaled drug products. Recent work demonstrated that the median of the modified chi-square ratio statistic (MmCSRS) is a promising metric for APSD equivalence testing of test (T) and reference (R) products as it can be applied to a reduced number of CI sites that are more relevant for lung deposition. This metric is also less sensitive to the increased variability often observed for low-deposition sites. A method to establish critical values for the MmCSRS is described here. This method considers the variability of the R product by employing a reference variance scaling approach that allows definition of critical values as a function of the observed variability of the R product. A stepwise CI equivalence test is proposed that integrates the MmCSRS as a method for comparing the relative shapes of CI profiles and incorporates statistical tests for assessing equivalence of single actuation content and impactor sized mass. This stepwise CI equivalence test was applied to 55 published CI profile scenarios, which were classified as equivalent or inequivalent by members of the Product Quality Research Institute working group (PQRI WG). The results of the stepwise CI equivalence test using a 25% difference in MmCSRS as an acceptance criterion provided the best matching with those of the PQRI WG as decisions of both methods agreed in 75% of the 55 CI profile scenarios.

  7. A suggested approach for imputation of missing dietary data for young children in daycare.

    PubMed

    Stevens, June; Ou, Fang-Shu; Truesdale, Kimberly P; Zeng, Donglin; Vaughn, Amber E; Pratt, Charlotte; Ward, Dianne S

    2015-01-01

    Parent-reported 24-h diet recalls are an accepted method of estimating intake in young children. However, many children eat while at childcare making accurate proxy reports by parents difficult. The goal of this study was to demonstrate a method to impute missing weekday lunch and daytime snack nutrient data for daycare children and to explore the concurrent predictive and criterion validity of the method. Data were from children aged 2-5 years in the My Parenting SOS project (n=308; 870 24-h diet recalls). Mixed models were used to simultaneously predict breakfast, dinner, and evening snacks (B+D+ES); lunch; and daytime snacks for all children after adjusting for age, sex, and body mass index (BMI). From these models, we imputed the missing weekday daycare lunches by interpolation using the mean lunch to B+D+ES [L/(B+D+ES)] ratio among non-daycare children on weekdays and the L/(B+D+ES) ratio for all children on weekends. Daytime snack data were used to impute snacks. The reported mean (± standard deviation) weekday intake was lower for daycare children [725 (±324) kcal] compared to non-daycare children [1,048 (±463) kcal]. Weekend intake for all children was 1,173 (±427) kcal. After imputation, weekday caloric intake for daycare children was 1,230 (±409) kcal. Daily intakes that included imputed data were associated with age and sex but not with BMI. This work indicates that imputation is a promising method for improving the precision of daily nutrient data from young children.

  8. Averaged ratio between complementary profiles for evaluating shape distortions of map projections and spherical hierarchical tessellations

    NASA Astrophysics Data System (ADS)

    Yan, Jin; Song, Xiao; Gong, Guanghong

    2016-02-01

    We describe a metric named averaged ratio between complementary profiles to represent the distortion of map projections, and the shape regularity of spherical cells derived from map projections or non-map-projection methods. The properties and statistical characteristics of our metric are investigated. Our metric (1) is a variable of numerical equivalence to both scale component and angular deformation component of Tissot indicatrix, and avoids the invalidation when using Tissot indicatrix and derived differential calculus for evaluating non-map-projection based tessellations where mathematical formulae do not exist (e.g., direct spherical subdivisions), (2) exhibits simplicity (neither differential nor integral calculus) and uniformity in the form of calculations, (3) requires low computational cost, while maintaining high correlation with the results of differential calculus, (4) is a quasi-invariant under rotations, and (5) reflects the distortions of map projections, distortion of spherical cells, and the associated distortions of texels. As an indicator of quantitative evaluation, we investigated typical spherical tessellation methods, some variants of tessellation methods, and map projections. The tessellation methods we evaluated are based on map projections or direct spherical subdivisions. The evaluation involves commonly used Platonic polyhedrons, Catalan polyhedrons, etc. Quantitative analyses based on our metric of shape regularity and an essential metric of area uniformity implied that (1) Uniform Spherical Grids and its variant show good qualities in both area uniformity and shape regularity, and (2) Crusta, Unicube map, and a variant of Unicube map exhibit fairly acceptable degrees of area uniformity and shape regularity.

  9. Test-retest intra-rater reliability of grip force in patients with stroke.

    PubMed

    Hammer, Ann; Lindmark, Birgitta

    2003-07-01

    Coefficients of repeatability and reproducibility can be guides in differentiating between real changes and measurement error. The aim was to evaluate test-retest intra-rater reliability of a clinical procedure measuring grip force with Grippit in stroke patients, to assess relationship between grip force of the hands and between sustained and peak grip force. Eighteen patients were tested using the Grippit at two occasions one hour apart. Each occasion comprised three consecutive trials per hand. The paretic hand needs to score a 50 N change within and between occasions to exceed the measurement error in 95% of the observations, irrespective of calculation method. Expressed by CV(within) the measurement error was 10%. There was no learning or fatigue effect during measuring. There was a wide variation between subjects but the mean ratio between sides was 0.66. The mean ratio between sustained and peak grip force was 0.80-0.84. The measurement errors were acceptable and the instrument can be recommended for the use in stroke patients at a department of rehabilitation medicine.

  10. Integrating Behavioral Health in Primary Care Using Lean Workflow Analysis: A Case Study.

    PubMed

    van Eeghen, Constance; Littenberg, Benjamin; Holman, Melissa D; Kessler, Rodger

    2016-01-01

    Primary care offices are integrating behavioral health (BH) clinicians into their practices. Implementing such a change is complex, difficult, and time consuming. Lean workflow analysis may be an efficient, effective, and acceptable method for use during integration. The objectives of this study were to observe BH integration into primary care and to measure its impact. This was a prospective, mixed-methods case study in a primary care practice that served 8,426 patients over a 17-month period, with 652 patients referred to BH services. Secondary measures included primary care visits resulting in BH referrals, referrals resulting in scheduled appointments, time from referral to the scheduled appointment, and time from the referral to the first visit. Providers and staff were surveyed on the Lean method. Referrals increased from 23 to 37 per 1000 visits (P < .001). Referrals resulted in more scheduled (60% to 74%; P < .001) and arrived visits (44% to 53%; P = .025). Time from referral to the first scheduled visit decreased (hazard ratio, 1.60; 95% confidence interval, 1.37-1.88) as did time to first arrived visit (hazard ratio, 1.36; 95% confidence interval, 1.14-1.62). Survey responses and comments were positive. This pilot integration of BH showed significant improvements in treatment initiation and other measures. Strengths of Lean analysis included workflow improvement, system perspective, and project success. Further evaluation is indicated. © Copyright 2016 by the American Board of Family Medicine.

  11. A quality-by-design study for an immediate-release tablet platform: examining the relative impact of active pharmaceutical ingredient properties, processing methods, and excipient variability on drug product quality attributes.

    PubMed

    Kushner, Joseph; Langdon, Beth A; Hicks, Ian; Song, Daniel; Li, Fasheng; Kathiria, Lalji; Kane, Anil; Ranade, Gautam; Agarwal, Kam

    2014-02-01

    The impact of filler-lubricant particle size ratio variation (3.4-41.6) on the attributes of an immediate-release tablet was compared with the impacts of the manufacturing method used (direct compression or dry granulation) and drug loading (1%, 5%, and 25%), particle size (D[4,3]: 8-114 μm), and drug type (theophylline or ibuprofen). All batches were successfully manufactured, except for direct compression of 25% drug loading of 8 μm (D[4,3]) drug, which exhibited very poor flow properties. All manufactured tablets possessed adequate quality attributes: tablet weight uniformity <4% RSD, tablet potency: 94%-105%, content uniformity <6% RSD, acceptance value ≤ 15, solid fraction: 0.82-0.86, tensile strength >1 MPa, friability ≤ 0.2% weight loss, and disintegration time < 4 min. The filler-lubricant particle size ratio exhibited the greatest impact on blend and granulation particle size and granulation flow, whereas drug property variation dominated blend flow, ribbon solid fraction, and tablet quality attributes. Although statistically significant effects were observed, the results of this study suggest that the manufacturability and performance of this immediate-release tablet formulation is robust to a broad range of variation in drug properties, both within-grade and extra-grade excipient particle size variations, and the choice of manufacturing method. © 2013 Wiley Periodicals, Inc. and the American Pharmacists Association.

  12. Practical statistics in pain research.

    PubMed

    Kim, Tae Kyun

    2017-10-01

    Pain is subjective, while statistics related to pain research are objective. This review was written to help researchers involved in pain research make statistical decisions. The main issues are related with the level of scales that are often used in pain research, the choice of statistical methods between parametric or nonparametric statistics, and problems which arise from repeated measurements. In the field of pain research, parametric statistics used to be applied in an erroneous way. This is closely related with the scales of data and repeated measurements. The level of scales includes nominal, ordinal, interval, and ratio scales. The level of scales affects the choice of statistics between parametric or non-parametric methods. In the field of pain research, the most frequently used pain assessment scale is the ordinal scale, which would include the visual analogue scale (VAS). There used to be another view, however, which considered the VAS to be an interval or ratio scale, so that the usage of parametric statistics would be accepted practically in some cases. Repeated measurements of the same subjects always complicates statistics. It means that measurements inevitably have correlations between each other, and would preclude the application of one-way ANOVA in which independence between the measurements is necessary. Repeated measures of ANOVA (RMANOVA), however, would permit the comparison between the correlated measurements as long as the condition of sphericity assumption is satisfied. Conclusively, parametric statistical methods should be used only when the assumptions of parametric statistics, such as normality and sphericity, are established.

  13. Carbonate pore system evaluation using the velocity-porosity-pressure relationship, digital image analysis, and differential effective medium theory

    NASA Astrophysics Data System (ADS)

    Lima Neto, Irineu A.; Misságia, Roseane M.; Ceia, Marco A.; Archilha, Nathaly L.; Oliveira, Lucas C.

    2014-11-01

    Carbonate reservoirs exhibit heterogeneous pore systems and a wide variety of grain types, which affect the rock's elastic properties and the reservoir parameter relationships. To study the Albian carbonates in the Campos Basin, a methodology is proposed to predict the amount of microporosity and the representative aspect ratio of these inclusions. The method assumes three pore-space scales in two representative inclusion scenarios: 1) a macro-mesopore median aspect ratio from the thin-section digital image analysis (DIA) and 2) a microporosity aspect ratio predicted based on the measured P-wave velocities. Through a laboratory analysis of 10 grainstone core samples of the Albian age, the P- and S-wave velocities (Vp and Vs) are evaluated at effective pressures of 0-10 MPa. The analytical theories in the proposed methodology are functions of the aspect ratios from the differential effective medium (DEM) theory, the macro-mesopore system recognized from the DIA, the amount of microporosity determined by the difference between the porosities estimated from laboratorial helium-gas and the thin-section petrographic images, and the P-wave velocities under dry effective pressure conditions. The DIA procedure is applied to estimate the local and global parameters, and the textural implications concerning ultrasonic velocities and image resolution. The macro-mesopore inclusions contribute to stiffer rocks and higher velocities, whereas the microporosity inclusions contribute to softer rocks and lower velocities. We observe a high potential for this methodology, which uses the microporosity aspect ratio inverted from Vp to predict Vs with a good agreement. The results acceptably characterize the Albian grainstones. The representative macro-mesopore aspect ratio is 0.5, and the inverted microporosity aspect ratio ranges from 0.01 to 0.07. The effective pressure induced an effect of slight porosity reduction during the triaxial tests, mainly in the microporosity inclusions, slightly changing the amount and the aspect ratio of the microporosity.

  14. How acceptable is paternalism? A survey-based study of clinician and nonclinician opinions on paternalistic decision making.

    PubMed

    Bailoor, Kunal; Valley, Thomas; Perumalswami, Chithra; Shuman, Andrew G; DeVries, Raymond; Zahuranec, Darin B

    2018-01-01

    We conducted an empirical study to explore clinician and lay opinions on the acceptability of physician paternalism. Respondents read a vignette describing a patient with brain hemorrhage facing urgent surgery that would be lifesaving but would result in long-term severe disability. Cases were randomized to show either low or high surrogate distress and certain or uncertain prognosis, with respondents rating the acceptability of not offering brain surgery. Clinicians (N = 169) were more likely than nonclinicians (N = 649) to find the doctor withholding surgery acceptable (30.2% vs. 11.4%, p ≤ 0.001). Among clinicians, the doctor withholding surgery was more acceptable when prognosis was certain to be poor (odds ratio [OR] 2.04, 95% confidence interval [CI] 1.04, 4.01). There was no effect of surrogate distress on clinician ratings. Responses among lay public were more variable. Given the differences in attitudes across clinicians and lay public, there is an ongoing need to engage stakeholders in the process of end-of-life decision making.

  15. Factors influencing humanitarian care and the treatment of local patients within the deployed military medical system: casualty referral limitations.

    PubMed

    Causey, Marlin; Rush, Robert M; Kjorstad, Randy J; Sebesta, James A

    2012-05-01

    Humanitarian medical care is an essential task of the deployed military health care system. The purpose of this study was to analyze referral acceptance in treating injured local national patients during Operation Enduring Freedom. A prospective observation study of local nationals who were referred for humanitarian trauma care in Afghanistan from March through August 2009. Sixty-six patients were referred for evacuation for suspected non-coalition-caused injuries. The bed status at the receiving hospital was defined as green (able to accept patients), amber (nearing capacity), and red (at capacity). The only factor associated with acceptance was the accepting hospital bed status (odds ratio = 1.57%, 95% confidence interval, 1.11-2.22; P = .009). Factors not significant were age, the province of origin, the type of referring facility, a prior operation before the request, patient status/affiliation, or the mechanism of injury. Humanitarian medical care is directly related to the capacity for high-acuity care because bed availability is the predominate reason for acceptance or rejection. Published by Elsevier Inc.

  16. Hunters' acceptability of the surveillance system and alternative surveillance strategies for classical swine fever in wild boar - a participatory approach.

    PubMed

    Schulz, Katja; Calba, Clémentine; Peyre, Marisa; Staubach, Christoph; Conraths, Franz J

    2016-09-06

    Surveillance measures can only be effective if key players in the system accept them. Acceptability, which describes the willingness of persons to contribute, is often analyzed using participatory methods. Participatory epidemiology enables the active involvement of key players in the assessment of epidemiological issues. In the present study, we used a participatory method recently developed by CIRAD (Centre de Coopération Internationale en Recherche Agronomique pour le Développement) to evaluate the functionality and acceptability of Classical Swine Fever (CSF) surveillance in wild boar in Germany, which is highly dependent on the participation of hunters. The acceptability of alternative surveillance strategies was also analyzed. By conducting focus group discussions, potential vulnerabilities in the system were detected and feasible alternative surveillance strategies identified. Trust in the current surveillance system is high, whereas the acceptability of the operation of the system is medium. Analysis of the acceptability of alternative surveillance strategies showed how risk-based surveillance approaches can be combined to develop strategies that have sufficient support and functionality. Furthermore, some surveillance strategies were clearly rejected by the hunters. Thus, the implementation of such strategies may be difficult. Participatory methods can be used to evaluate the functionality and acceptability of existing surveillance plans for CSF among hunters and to optimize plans regarding their chances of successful implementation.

  17. On the use of transition matrix methods with extended ensembles.

    PubMed

    Escobedo, Fernando A; Abreu, Charlles R A

    2006-03-14

    Different extended ensemble schemes for non-Boltzmann sampling (NBS) of a selected reaction coordinate lambda were formulated so that they employ (i) "variable" sampling window schemes (that include the "successive umbrella sampling" method) to comprehensibly explore the lambda domain and (ii) transition matrix methods to iteratively obtain the underlying free-energy eta landscape (or "importance" weights) associated with lambda. The connection between "acceptance ratio" and transition matrix methods was first established to form the basis of the approach for estimating eta(lambda). The validity and performance of the different NBS schemes were then assessed using as lambda coordinate the configurational energy of the Lennard-Jones fluid. For the cases studied, it was found that the convergence rate in the estimation of eta is little affected by the use of data from high-order transitions, while it is noticeably improved by the use of a broader window of sampling in the variable window methods. Finally, it is shown how an "elastic" window of sampling can be used to effectively enact (nonuniform) preferential sampling over the lambda domain, and how to stitch the weights from separate one-dimensional NBS runs to produce a eta surface over a two-dimensional domain.

  18. Different Spectrophotometric Methods for Simultaneous Determination of Trelagliptin and Its Acid Degradation Product

    PubMed Central

    Hassan, Mostafa A.; Zaghary, Wafaa A.

    2018-01-01

    New spectrophotometric and chemometric methods were carried out for the simultaneous assay of trelagliptin (TRG) and its acid degradation product (TAD) and applied successfully as a stability indicating assay to recently approved Zafatek® tablets. TAD was monitored using TLC to ensure complete degradation. Furthermore, HPLC was used to confirm dealing with one major acid degradation product. The proposed methods were developed by manipulating zero-order, first-derivative, and ratio spectra of TRG and TAD using simultaneous equation, first-derivative, and mean-centering methods, respectively. Using Spectra Manager II and Minitab v.14 software, the absorbance at 274 nm–260.4 nm, amplitudes at 260.4 nm–274.0 nm, and mean-centered values at 287.6 nm–257.2 nm were measured against methanol as a blank for TRG and TAD, respectively. Linearity and the other validation parameters were acceptable at concentration ranges of 5–50 μg/mL and 2.5–25 μg/mL for TRG and TAD, respectively. Using one-way analysis of variance (ANOVA), the optimized methods were compared and proved to be accurate for the simultaneous assay of TRG and TAD. PMID:29629213

  19. Different Spectrophotometric Methods for Simultaneous Determination of Trelagliptin and Its Acid Degradation Product.

    PubMed

    Mowaka, Shereen; Ayoub, Bassam M; Hassan, Mostafa A; Zaghary, Wafaa A

    2018-01-01

    New spectrophotometric and chemometric methods were carried out for the simultaneous assay of trelagliptin (TRG) and its acid degradation product (TAD) and applied successfully as a stability indicating assay to recently approved Zafatek® tablets. TAD was monitored using TLC to ensure complete degradation. Furthermore, HPLC was used to confirm dealing with one major acid degradation product. The proposed methods were developed by manipulating zero-order, first-derivative, and ratio spectra of TRG and TAD using simultaneous equation, first-derivative, and mean-centering methods, respectively. Using Spectra Manager II and Minitab v.14 software, the absorbance at 274 nm-260.4 nm, amplitudes at 260.4 nm-274.0 nm, and mean-centered values at 287.6 nm-257.2 nm were measured against methanol as a blank for TRG and TAD, respectively. Linearity and the other validation parameters were acceptable at concentration ranges of 5-50  μ g/mL and 2.5-25  μ g/mL for TRG and TAD, respectively. Using one-way analysis of variance (ANOVA), the optimized methods were compared and proved to be accurate for the simultaneous assay of TRG and TAD.

  20. Smart Money

    ERIC Educational Resources Information Center

    Ullman, Ellen

    2009-01-01

    From using virtualization technology to accepting lunch payments online, school districts are seeking money-saving methods. In this article, the author discusses some methods used by school districts that allow them to save money from using virtualization technology to accepting lunch payments online.

  1. [Emergency contraception in Brazil: facilitators and barriers].

    PubMed

    Hardy, E; Duarte, G A; Osis, M J; Arce, X E; Possan, M

    2001-01-01

    A multi-centered qualitative study was conducted in Brazil, Chile, and Mexico to assess the acceptability of emergency contraception both among potential users and possible providers, authorities, and opinion-makers, and to identify (according to participants' perceptions) factors facilitating or hindering the method's use and the most appropriate strategies to disseminate information and provide the method. Data were collected through semi-structured interviews, group interviews, and discussion groups, which were tape-recorded and transcribed. A thematic analysis of this material was conducted. Acceptability of emergency contraception was high among participants, who also felt that there were no barriers towards its acceptance by the population. Participants felt that the method's acceptability would be greater if it were included in reproductive health programs, emphasizing its prescription for emergency situations. Participants highlighted that strategic components in Brazil would be training of providers and inclusion of the method in family planning services.

  2. SU-F-T-383: Robustness for Patient Setup Error in Total Body Irradiation Using Volumetric Modulated Arc Therapy (VMAT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takahashi, Y; National Cancer Center, Kashiwa, Chiba; Tachibana, H

    Purpose: Total body irradiation (TBI) and total marrow irradiation (TMI) using Tomotherapy have been reported. A gantry-based linear accelerator uses one isocenter during one rotational irradiation. Thus, 3–5 isocenter points should be used for a whole plan of TBI-VMAT during smoothing out the junctional dose distribution. IGRT provides accurate and precise patient setup for the multiple junctions, however it is evident that some setup errors should occur and affect accuracy of dose distribution in the area. In this study, we evaluated the robustness for patient’s setup error in VMAT-TBI. Methods: VMAT-TBI Planning was performed in an adult whole-body human phantommore » using Eclipse. Eight full arcs with four isocenter points using 6MV-X were used to cover the entire whole body. Dose distribution was optimized using two structures of patient’s body as PTV and lung. The two arcs were shared with one isocenter and the two arcs were 5 cm-overlapped with the other two arcs. Point absolute dose using ionization-chamber and planer relative dose distribution using film in the junctional regions were performed using water-equivalent slab phantom. In the measurements, several setup errors of (+5∼−5mm) were added. Results: The result of the chamber measurement shows the deviations were within ±3% when the setup errors were within ±3 mm. In the planer evaluation, the pass ratio of gamma evaluation (3%/2mm) shows more than 90% if the errors within ±3 mm. However, there were hot/cold areas in the edge of the junction even with acceptable gamma pass ratio. 5 mm setup error caused larger hot and cold areas and the dosimetric acceptable areas were decreased in the overlapped areas. Conclusion: It can be clinically acceptable for VMAT-TBI when patient setup error is within ±3mm. Averaging effects from patient random error would be helpful to blur the hot/cold area in the junction.« less

  3. Assessing the utility of cancer-registry-processed cause of death in calculating cancer-specific survival.

    PubMed

    Hu, Chung-Yuan; Xing, Yan; Cormier, Janice N; Chang, George J

    2013-05-15

    Cancer registries use algorithms to process cause of death (COD) data from death certificates, but uncertainties remain regarding the accuracy and utility of those data in calculating cancer-specific survival (CSS). Because it is impractical to reconfirm the COD through meticulous review of the primary medical records, the observed cancer deaths could be compared with the number of attributed deaths, as estimated by using a relative survival (RS) approach, to determine utility in CSS estimation. Six major cancer types were evaluated using Surveillance, Epidemiology, and End Results (SEER) data (1988-1999 cohort). The COD utility was quantified by using the observed-to-expected ratio (O/E ratio) approach, which was calculated as the SEER-documented observed number of cancer-specific deaths divided by the number of expected deaths attributed to the malignancies as estimated using a RS approach. Favorable utility would have an O/E ratio close to 1. In total, 338,445 patients were identified; and their O/E ratios were 0.97, 0.98, 0.90, 1.07, 1.02, and 0.92 for breast, colorectal, lung, melanoma, prostate, and pancreas cancer, respectively. O/E ratios varied slightly with patients' age, race, and tumor stage, but not by sex. CSS for patients with lung cancer appeared to be overestimated considerably. Patients with multiple cancer diagnoses had poor O/E ratios compared with those who had only 1 cancer. The utility of COD in calculating CSS depended variously on the risk of cancer-related mortality and nontumor factors. However, the impact of this variation on CSS generally was small. The current results indicated that the COD assigned by cancer registries has acceptable validity, and CSS is considered an acceptable surrogate for RS in most circumstances. Copyright © 2013 American Cancer Society.

  4. Comparative analysis of background EEG activity in childhood absence epilepsy during valproate treatment: a standardized, low-resolution, brain electromagnetic tomography (sLORETA) study.

    PubMed

    Shin, Jung-Hyun; Eom, Tae-Hoon; Kim, Young-Hoon; Chung, Seung-Yun; Lee, In-Goo; Kim, Jung-Min

    2017-07-01

    Valproate (VPA) is an antiepileptic drug (AED) used for initial monotherapy in treating childhood absence epilepsy (CAE). EEG might be an alternative approach to explore the effects of AEDs on the central nervous system. We performed a comparative analysis of background EEG activity during VPA treatment by using standardized, low-resolution, brain electromagnetic tomography (sLORETA) to explore the effect of VPA in patients with CAE. In 17 children with CAE, non-parametric statistical analyses using sLORETA were performed to compare the current density distribution of four frequency bands (delta, theta, alpha, and beta) between the untreated and treated condition. Maximum differences in current density were found in the left inferior frontal gyrus for the delta frequency band (log-F-ratio = -1.390, P > 0.05), the left medial frontal gyrus for the theta frequency band (log-F-ratio = -0.940, P > 0.05), the left inferior frontal gyrus for the alpha frequency band (log-F-ratio = -0.590, P > 0.05), and the left anterior cingulate for the beta frequency band (log-F-ratio = -1.318, P > 0.05). However, none of these differences were significant (threshold log-F-ratio = ±1.888, P < 0.01; threshold log-F-ratio = ±1.722, P < 0.05). Because EEG background is accepted as normal in CAE, VPA would not be expected to significantly change abnormal thalamocortical oscillations on a normal EEG background. Therefore, our results agree with currently accepted concepts but are not consistent with findings in some previous studies.

  5. Fatal Crash Involvements -- What Are The Odds?

    DOT National Transportation Integrated Search

    1997-07-01

    The risk of being involved in a fatal crash varies considerably depending on : specific crash characteristics, i.e., those of the driver, vehicle and : environment. A generally accepted measure of the risk of a fatal crash is the : ratio between the ...

  6. Probabilistic Modeling of Settlement Risk at Land Disposal Facilities - 12304

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foye, Kevin C.; Soong, Te-Yang

    2012-07-01

    The long-term reliability of land disposal facility final cover systems - and therefore the overall waste containment - depends on the distortions imposed on these systems by differential settlement/subsidence. The evaluation of differential settlement is challenging because of the heterogeneity of the waste mass (caused by inconsistent compaction, void space distribution, debris-soil mix ratio, waste material stiffness, time-dependent primary compression of the fine-grained soil matrix, long-term creep settlement of the soil matrix and the debris, etc.) at most land disposal facilities. Deterministic approaches to long-term final cover settlement prediction are not able to capture the spatial variability in the wastemore » mass and sub-grade properties which control differential settlement. An alternative, probabilistic solution is to use random fields to model the waste and sub-grade properties. The modeling effort informs the design, construction, operation, and maintenance of land disposal facilities. A probabilistic method to establish design criteria for waste placement and compaction is introduced using the model. Random fields are ideally suited to problems of differential settlement modeling of highly heterogeneous foundations, such as waste. Random fields model the seemingly random spatial distribution of a design parameter, such as compressibility. When used for design, the use of these models prompts the need for probabilistic design criteria. It also allows for a statistical approach to waste placement acceptance criteria. An example design evaluation was performed, illustrating the use of the probabilistic differential settlement simulation methodology to assemble a design guidance chart. The purpose of this design evaluation is to enable the designer to select optimal initial combinations of design slopes and quality control acceptance criteria that yield an acceptable proportion of post-settlement slopes meeting some design minimum. For this specific example, relative density, which can be determined through field measurements, was selected as the field quality control parameter for waste placement. This technique can be extended to include a rigorous performance-based methodology using other parameters (void space criteria, debris-soil mix ratio, pre-loading, etc.). As shown in this example, each parameter range, or sets of parameter ranges can be selected such that they can result in an acceptable, long-term differential settlement according to the probabilistic model. The methodology can also be used to re-evaluate the long-term differential settlement behavior at closed land disposal facilities to identify, if any, problematic facilities so that remedial action (e.g., reinforcement of upper and intermediate waste layers) can be implemented. Considering the inherent spatial variability in waste and earth materials and the need for engineers to apply sound quantitative practices to engineering analysis, it is important to apply the available probabilistic techniques to problems of differential settlement. One such method to implement probability-based differential settlement analyses for the design of landfill final covers has been presented. The design evaluation technique presented is one tool to bridge the gap from deterministic practice to probabilistic practice. (authors)« less

  7. Equity Theory Ratios as Causal Schemas.

    PubMed

    Arvanitis, Alexios; Hantzi, Alexandra

    2016-01-01

    Equity theory approaches justice evaluations based on ratios of exchange inputs to exchange outcomes. Situations are evaluated as just if ratios are equal and unjust if unequal. We suggest that equity ratios serve a more fundamental cognitive function than the evaluation of justice. More particularly, we propose that they serve as causal schemas for exchange outcomes, that is, they assist in determining whether certain outcomes are caused by inputs of other people in the context of an exchange process. Equality or inequality of ratios in this sense points to an exchange process. Indeed, Study 1 shows that different exchange situations, such as disproportional or balanced proportional situations, create perceptions of give-and-take on the basis of equity ratios. Study 2 shows that perceptions of justice are based more on communicatively accepted rules of interaction than equity-based evaluations, thereby offering a distinction between an attribution and an evaluation cognitive process for exchange outcomes.

  8. Equity Theory Ratios as Causal Schemas

    PubMed Central

    Arvanitis, Alexios; Hantzi, Alexandra

    2016-01-01

    Equity theory approaches justice evaluations based on ratios of exchange inputs to exchange outcomes. Situations are evaluated as just if ratios are equal and unjust if unequal. We suggest that equity ratios serve a more fundamental cognitive function than the evaluation of justice. More particularly, we propose that they serve as causal schemas for exchange outcomes, that is, they assist in determining whether certain outcomes are caused by inputs of other people in the context of an exchange process. Equality or inequality of ratios in this sense points to an exchange process. Indeed, Study 1 shows that different exchange situations, such as disproportional or balanced proportional situations, create perceptions of give-and-take on the basis of equity ratios. Study 2 shows that perceptions of justice are based more on communicatively accepted rules of interaction than equity-based evaluations, thereby offering a distinction between an attribution and an evaluation cognitive process for exchange outcomes. PMID:27594846

  9. Cost-effectiveness of Extended Buprenorphine-Naloxone Treatment for Opioid-Dependent Youth: Data from a Randomized Trial

    PubMed Central

    Polsky, Daniel; Glick, Henry A.; Yang, Jianing; Subramaniam, Geetha A.; Poole, Sabrina A.; Woody, George E.

    2010-01-01

    Introduction The objective is to estimate cost, net social cost, and cost-effectiveness in a clinical trial of extended buprenorphine-naloxone treatment versus brief detoxification treatment in opioid-dependent youth. Methods Economic evaluation of a clinical trial conducted at 6 community outpatient treatment programs from July 2003 to December 2006 including 152 patients aged 15 to 21 years who were randomized to 12 weeks of buprenorphine-naloxone (BUP) or a 14-day taper (DETOX). BUP patients were prescribed up to 24 mg per day for 9 weeks and then tapered to zero at the end of week 12. DETOX patients were prescribed up to 14 mg per day and then tapered to zero on day 14. All were offered twice weekly drug counseling. Data were collected prospectively during the 12-week treatment and at follow-up interviews at months 6, 9, and 12. Results The 12-week outpatient study treatment cost was $1514 (p<0.001) higher for BUP relative to DETOX. One-year total direct medical cost was only $83 higher for BUP (p=0.97). The cost-effectiveness ratio of BUP relative to DETOX was $1,376 in terms of 1-year direct medical cost per quality-adjusted life year (QALY) and $25,049 in terms of outpatient treatment program cost per QALY. The acceptability curve suggests that the cost-effectiveness ratio of BUP relative to DETOX has an 86% chance of being accepted as cost-effective for a threshold of $100,000 per QALY. Conclusions Extended buprenorphine-naloxone treatment relative to brief detoxification is cost effective in the U.S. health care system for the outpatient treatment of opioid-dependent youth. PMID:20626379

  10. Associations Between Peer Counseling and Breastfeeding Initiation and Duration: An Analysis of Minnesota Participants in the Special Supplemental Nutrition Program for Women, Infants, and Children (WIC).

    PubMed

    McCoy, Marcia Burton; Geppert, Joni; Dech, Linda; Richardson, Michaela

    2018-01-01

    Background Peer counseling (PC) has been associated with increased breastfeeding initiation and duration, but few analyses have examined the Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) model for peer counseling or the continuation of breastfeeding from birth through 12 months postpartum. Objectives Identify associations between Minnesota WIC Peer Breastfeeding Support Program services and breastfeeding initiation and continuation. Methods Retrospective analysis of observational data from the Minnesota WIC program's administrative database of women who gave birth in 2012 and accepted a PC program referral prenatally (n = 2219). Multivariate logistic regression and Cox regression models examined associations between peer services and breastfeeding initiation and continuation of any breastfeeding. Results Among women who accepted referral into a PC program, odds of initiation were significantly higher among those who received peer services (Odds Ratio (OR): 1.66; 95% CI 1.19-2.32), after adjusting for confounders. Women who received peer services had a significantly lower hazard of breastfeeding discontinuation from birth through 12 months postpartum than women who did not receive services. (Hazard Ratio (HR) month one: 0.45; 95% CI 0.33-0.61; months two through twelve: 0.33; 95% CI 0.18-0.60). The effect of peer counseling did not differ significantly by race and ethnicity, taking into account mother's country of origin. Conclusion for practice Receipt of peer services was positively associated with breastfeeding initiation and continued breastfeeding from birth through 12 months postpartum. Making peer services available to more women, especially in communities with low initiation and duration, could improve maternal and child health in Minnesota.

  11. Acceptance of dying: a discourse analysis of palliative care literature.

    PubMed

    Zimmermann, Camilla

    2012-07-01

    The subject of death denial in the West has been examined extensively in the sociological literature. However, there has not been a similar examination of its "opposite", the acceptance of death. In this study, I use the qualitative method of discourse analysis to examine the use of the term "acceptance" of dying in the palliative care literature from 1970 to 2001. A Medline search was performed by combining the text words "accept or acceptance" with the subject headings "terminal care or palliative care or hospice care", and restricting the search to English language articles in clinical journals discussing acceptance of death in adults. The 40 articles were coded and analysed using a critical discourse analysis method. This paper focuses on the theme of acceptance as integral to palliative care, which had subthemes of acceptance as a goal of care, personal acceptance of healthcare workers, and acceptance as a facilitator of care. For patients and families, death acceptance is a goal that they can be helped to attain; for palliative care staff, acceptance of dying is a personal quality that is a precondition for effective practice. Acceptance not only facilitates the dying process for the patient and family, but also renders care easier. The analysis investigates the intertextuality of these themes with each other and with previous texts. From a Foucauldian perspective, I suggest that the discourse on acceptance of dying represents a productive power, which disciplines patients through apparent psychological and spiritual gratification, and encourages participation in a certain way to die. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. The Ratios of Pre-emulsified Duck Skin for Optimized Processing of Restructured Ham.

    PubMed

    Shim, Jae-Yun; Kim, Tae-Kyung; Kim, Young-Boong; Jeon, Ki-Hong; Ahn, Kwang-Il; Paik, Hyun-Dong; Choi, Yun-Sang

    2018-02-01

    The purpose of this study was to investigate the quality of duck ham formulated with duck skin through the pre-emulsification process. The experiments to investigate the quality characteristics of duck ham were carried out to measure proximate composition, cooking loss, emulsion stability, pH, color, texture profile analysis, apparent viscosity, and sensory characteristics. Duck ham was prepared with various ratios of duck skin in pre-emulsion as follows: Control (duct skin 30%), T1 (duck skin 20% + pre-emulsified duck skin 10%), T2 (duck skin 15% + pre-emulsified duck skin 15%), T3 (duck skin 10% + pre-emulsified duck skin 20%), and T4 (pre-emulsified duck skin 30%). As the ratio of duck skin to pre-emulsified skin changed, the quality of duck ham in terms of moisture content, fat content, cooking loss, emulsion stability, lightness, textural analysis, apparent viscosity, and overall acceptability changed. The moisture content of T2 was the highest ( p <0.05) and that of the control and T4 was the lowest ( p <0.05). The fat content of control was higher than all treatments ( p <0.05). T2 had the lowest values in cooking loss, total expressible fluid, fat separation, hardness, springiness, and gumminess ( p <0.05). The score of overall acceptability of all treatments with pre-emulsified skin was higher than control ( p <0.05). Therefore, the pre-emulsification process can improve the quality characteristics of duck ham and 1:1 ratio of duck skin and pre-emulsified skin was the proper ratio to improve the quality characteristics of duck ham.

  13. Certified Rehabilitation Counselors Role in the Acceptance of Disability of Returning Afghanistan and Iraq Military Veterans with Disabilities

    ERIC Educational Resources Information Center

    Frain, Michael; Torres, Ayse; Bishop, Malachy; Sakala, Kelly; Khan-Jordan, Cindy; Schoen, Barbara

    2016-01-01

    Purpose: To understand the level of acceptance of disability by veterans and rehabilitation counselor's role in that acceptance. Method: The Acceptance of Disability Scale-Revised was given to 117 veterans from the wars in Afghanistan and Iraq who acquired disabilities. Their experiences working with certified rehabilitation counselors was also…

  14. Understanding Technology Acceptance in Pre-Service Teachers of Primary Mathematics in Hong Kong

    ERIC Educational Resources Information Center

    Wong, Gary K. W.

    2015-01-01

    The adoption of educational technology in teaching depends on how well a teacher accepts it. This paper draws on a technology acceptance survey of pre-service primary mathematics teachers in Hong Kong to study the factors influencing their technology acceptance. This work adopted a mixed method approach, in which quantitative data were collected…

  15. Apollo experience report environmental acceptance testing

    NASA Technical Reports Server (NTRS)

    Laubach, C. H. M.

    1976-01-01

    Environmental acceptance testing was used extensively to screen selected spacecraft hardware for workmanship defects and manufacturing flaws. The minimum acceptance levels and durations and methods for their establishment are described. Component selection and test monitoring, as well as test implementation requirements, are included. Apollo spacecraft environmental acceptance test results are summarized, and recommendations for future programs are presented.

  16. Application of neural networks with novel independent component analysis methodologies to a Prussian blue modified glassy carbon electrode array.

    PubMed

    Wang, Liang; Yang, Die; Fang, Cheng; Chen, Zuliang; Lesniewski, Peter J; Mallavarapu, Megharaj; Naidu, Ravendra

    2015-01-01

    Sodium potassium absorption ratio (SPAR) is an important measure of agricultural water quality, wherein four exchangeable cations (K(+), Na(+), Ca(2+) and Mg(2+)) should be simultaneously determined. An ISE-array is suitable for this application because its simplicity, rapid response characteristics and lower cost. However, cross-interferences caused by the poor selectivity of ISEs need to be overcome using multivariate chemometric methods. In this paper, a solid contact ISE array, based on a Prussian blue modified glassy carbon electrode (PB-GCE), was applied with a novel chemometric strategy. One of the most popular independent component analysis (ICA) methods, the fast fixed-point algorithm for ICA (fastICA), was implemented by the genetic algorithm (geneticICA) to avoid the local maxima problem commonly observed with fastICA. This geneticICA can be implemented as a data preprocessing method to improve the prediction accuracy of the Back-propagation neural network (BPNN). The ISE array system was validated using 20 real irrigation water samples from South Australia, and acceptable prediction accuracies were obtained. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Three dimensional HiLo-based structured illumination for a digital scanned laser sheet microscopy (DSLM) in thick tissue imaging

    PubMed Central

    Bhattacharya, Dipanjan; Singh, Vijay Raj; Zhi, Chen; So, Peter T. C.; Matsudaira, Paul; Barbastathis, George

    2012-01-01

    Laser sheet based microscopy has become widely accepted as an effective active illumination method for real time three-dimensional (3D) imaging of biological tissue samples. The light sheet geometry, where the camera is oriented perpendicular to the sheet itself, provides an effective method of eliminating some of the scattered light and minimizing the sample exposure to radiation. However, residual background noise still remains, limiting the contrast and visibility of potentially interesting features in the samples. In this article, we investigate additional structuring of the illumination for improved background rejection, and propose a new technique, “3D HiLo” where we combine two HiLo images processed from orthogonal directions to improve the condition of the 3D reconstruction. We present a comparative study of conventional structured illumination based demodulation methods, namely 3Phase and HiLo with a newly implemented 3D HiLo approach and demonstrate that the latter yields superior signal-to-background ratio in both lateral and axial dimensions, while simultaneously suppressing image processing artifacts. PMID:23262684

  18. Three dimensional HiLo-based structured illumination for a digital scanned laser sheet microscopy (DSLM) in thick tissue imaging.

    PubMed

    Bhattacharya, Dipanjan; Singh, Vijay Raj; Zhi, Chen; So, Peter T C; Matsudaira, Paul; Barbastathis, George

    2012-12-03

    Laser sheet based microscopy has become widely accepted as an effective active illumination method for real time three-dimensional (3D) imaging of biological tissue samples. The light sheet geometry, where the camera is oriented perpendicular to the sheet itself, provides an effective method of eliminating some of the scattered light and minimizing the sample exposure to radiation. However, residual background noise still remains, limiting the contrast and visibility of potentially interesting features in the samples. In this article, we investigate additional structuring of the illumination for improved background rejection, and propose a new technique, "3D HiLo" where we combine two HiLo images processed from orthogonal directions to improve the condition of the 3D reconstruction. We present a comparative study of conventional structured illumination based demodulation methods, namely 3Phase and HiLo with a newly implemented 3D HiLo approach and demonstrate that the latter yields superior signal-to-background ratio in both lateral and axial dimensions, while simultaneously suppressing image processing artifacts.

  19. Drying of restructured chips made from the old stalks of Asparagus officinalis: impact of different drying methods.

    PubMed

    Liu, Zhenbin; Zhang, Min; Wang, Yuchuan

    2016-06-01

    Old stalks of Asparagus officinalis, which account for one third of the total length of each spear, are always discarded as waste. To make full use of the resource, a kind of restructured Asparagus officinalis chip was made. The effects of pulse-spouted microwave-assisted vacuum drying (PSMVD), microwave-assisted vacuum drying (MVD) and vacuum drying (VD) on texture, color and other quality parameters of restructured chips were then studied to obtain high-quality dried chips. Results indicated that the drying time was significantly affected by drying methods, and PSMVD had much better drying uniformity than MVD. The expansion ratio and crispness of chips increased with increasing microwave power and vacuum degree. The browning reaction of samples in VD was more serious, which was confirmed by the results of color test and electronic nose. The PSMVD drying method showed much better drying uniformity than MVD. The dried chips obtained by PSMVD showed optimal quality and were more readily accepted by consumers. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.

  20. A robust and versatile signal-on fluorescence sensing strategy based on SYBR Green I dye and graphene oxide

    PubMed Central

    Qiu, Huazhang; Wu, Namei; Zheng, Yanjie; Chen, Min; Weng, Shaohuang; Chen, Yuanzhong; Lin, Xinhua

    2015-01-01

    A robust and versatile signal-on fluorescence sensing strategy was developed to provide label-free detection of various target analytes. The strategy used SYBR Green I dye and graphene oxide as signal reporter and signal-to-background ratio enhancer, respectively. Multidrug resistance protein 1 (MDR1) gene and mercury ion (Hg2+) were selected as target analytes to investigate the generality of the method. The linear relationship and specificity of the detections showed that the sensitive and selective analyses of target analytes could be achieved by the proposed strategy with low detection limits of 0.5 and 2.2 nM for MDR1 gene and Hg2+, respectively. Moreover, the strategy was used to detect real samples. Analytical results of MDR1 gene in the serum indicated that the developed method is a promising alternative approach for real applications in complex systems. Furthermore, the recovery of the proposed method for Hg2+ detection was acceptable. Thus, the developed label-free signal-on fluorescence sensing strategy exhibited excellent universality, sensitivity, and handling convenience. PMID:25565810

  1. Telecoil-mode hearing aid compatibility performance requirements for wireless and cordless handsets: magnetic signal-to-noise.

    PubMed

    Julstrom, Stephen; Kozma-Spytek, Linda; Isabelle, Scott

    2011-09-01

    During the revision of the American National Standards Institute (ANSI) C63.19 and the development of the ANSI/Telecommunications Industry Association-1083 hearing aid compatibility standards, it became evident that additional data concerning user acceptance of interfering magnetic noises generated by wireless and cordless telephones were needed in order to determine the requirements for telecoil-coupling compatibility. Further insight was needed into the magnetic signal-to-noise (S/N) ratios required to achieve specific levels of telephone usability by hearing aid wearers. (A companion article addresses magnetic signal level requirements.) Test subjects used their own hearing aids. The magnetic signals were applied through large magnetic head-worn coils, selected for the field orientation appropriate for each hearing aid. After adjusting their aid's volume control to an acoustic speech reference, the subjects adjusted the applied magnetic signal level to find their Most Comfortable Level (MCL). Each subject then adjusted the levels of six of eight different representative interfering noises to three levels of subjective telephone usability: "usable for a brief call," "acceptable for normal use," and "excellent performance." Each subject's objective noise audibility threshold in the presence of speech was also obtained for the various noise types. The 57 test subjects covered an age range of 22 to 79 yr, with a self-reported hearing loss duration of 12 to 72 yr. All had telecoils that they used for at least some telecommunications needs. The self-reported degree of hearing loss ranged from moderate to profound. A guided intake questionnaire yielded general background information for each subject. A test control box fed by prepared speech and noise recordings from computer files enabled the subject or the tester, depending on the portion of the test, to select A-weighting-normalized noise interference levels in 1.25 dB steps relative to the selected MCL. For each subject for each tested noise type, the values for the selected S/N ratios were recorded for the three categories of subjective usability and the objective noise threshold. About half of the test subjects needed a minimum 21 dB S/N ratio for them to consider their listening experience "acceptable for normal use" of a telephone. With a 30 dB S/N ratio, about 85% of the subjects reported normal use acceptability. Significant differences were apparent in the measured S/N user requirements among the noise types, though, indicating a deficiency in an A-weighted level measurement's ability to consistently predict the subjective acceptability of the various noises. An improved weighting function having both spectral and temporal components was developed to substantially eliminate these predictive inconsistencies. The interfering noise level that subjects chose for a telephone usability rating of "excellent performance" matched closely their objectively measured noise audibility threshold. A rating of "acceptable for normal use" was typically achieved at a 4 dB higher noise level, and a rating of "usable for a brief call," at a 10.4 dB higher noise level. These results did not relate significantly to noise type or to the subject's aided noise-in-speech hearing acuity. American Academy of Audiology.

  2. The promises and limitations of female-initiated methods of HIV/STI protection

    PubMed Central

    Mantell, Joanne E.; Dworkin, Shari L.; Exner, Theresa M.; Hoffman, Susie; Smit, Jenni A.; Susser, Ida

    2014-01-01

    New methods are now available, and others are being developed, that could enable women to take the initiative in preventing sexually transmitted infections. However, attempts to capitalize on “female-controlled” preventive methods thus far have met with limited success. Female-initiated methods were introduced to intervene in the state of gender relations and assist women who are disempowered vis-à-vis their male partners. Paradoxically, however, we underscore that it is the very structure of regional and local gender relations that shapes the acceptability (or lack of acceptability) of these methods. This paper specifically addresses how the structure of gender relations—for better and for worse—shapes the promises and limitations of widespread use and acceptance of female-initiated methods. We draw on examples from around the world to underscore how the regional specificities of gender (in)equality shape the acceptance, negotiation, and use of these methods. Simultaneously, we demonstrate how the introduction and sustained use of methods are shaped by gender relations and offer possibilities for reinforcing or challenging their current state. Based on our analyses, we offer key policy and programmatic recommendations to increase promotion and effective use of women-initiated HIV/STI protection methods for both women and men. PMID:16814912

  3. Home Videophones Improve Direct Observation in Tuberculosis Treatment: A Mixed Methods Evaluation

    PubMed Central

    Wade, Victoria A.; Karnon, Jonathan; Eliott, Jaklin A.; Hiller, Janet E.

    2012-01-01

    Background The use of direct observation to monitor tuberculosis treatment is controversial: cost, practical difficulties, and lack of patient acceptability limit effectiveness. Telehealth is a promising alternative delivery method for improving implementation. This study aimed to evaluate the clinical and cost-effectiveness of a telehealth service delivering direct observation, compared to an in-person drive-around service. Methodology/Principal Findings The study was conducted within a community nursing service in South Australia. Telehealth patients received daily video calls at home on a desktop videophone provided by the nursing call center. A retrospective cohort study assessed the effectiveness of the telehealth and traditional forms of observation, defined by the proportion of missed observations recorded in case notes. This data was inputted to a model, estimating the incremental cost-effectiveness ratio (ICER) of telehealth. Semi-structured interviews were conducted with current patients, community nursing and Chest Clinic staff, concerning service acceptability, usability and sustainability. The percentage of missed observations for the telehealth service was 12.1 (n = 58), compared to 31.1 for the in-person service (n = 70). Most of the difference of 18.9% (95% CI: 12.2 – 25.4) was due to fewer pre-arranged absences. The economic analysis calculated the ICER to be AUD$1.32 (95% CI: $0.51 – $2.26) per extra day of successful observation. The video service used less staff time, and became dominant if implemented on a larger scale and/or with decreased technology costs. Qualitative analysis found enabling factors of flexible timing, high patient acceptance, staff efficiency, and Chest Clinic support. Substantial technical problems were manageable, and improved liaison between the nursing service and Chest Clinic was an unexpected side-benefit. Conclusions/Significance Home video observation is a patient-centered, resource efficient way of delivering direct observation for TB, and is cost-effective when compared with a drive-around service. Future research is recommended to determine applicability and effectiveness in other settings. PMID:23226243

  4. Simplified computer-aided detection scheme of microcalcification clusters in digital breast tomosynthesis images.

    PubMed

    Ji-Wook Jeong; Seung-Hoon Chae; Eun Young Chae; Hak Hee Kim; Young Wook Choi; Sooyeul Lee

    2016-08-01

    A computer-aided detection (CADe) algorithm for clustered microcalcifications (MCs) in reconstructed digital breast tomosynthesis (DBT) images is suggested. The MC-like objects were enhanced by a Hessian-based 3D calcification response function, and a signal-to-noise ratio (SNR) enhanced image was also generated to screen the MC clustering seed objects. A connected component segmentation method was used to detect the cluster seed objects, which were considered as potential clustering centers of MCs. Bounding cubes for the accepted clustering seed candidate were generated and the overlapping cubes were combined and examined. After the MC clustering and false-positive (FP) reduction step, the average number of FPs was estimated to be 0.87 per DBT volume with a sensitivity of 90.5%.

  5. Carbon dioxide emissions, output, and energy consumption categories in Algeria.

    PubMed

    Amri, Fethi

    2017-06-01

    This study examines the relation between CO 2 emissions, income, non-renewable, and renewable energy consumption in Algeria during the period extending from 1980 to 2011. Our work gives particular attention to the validity of environmental Kuznets curve (EKC) hypothesis. The autoregressive distributed lag (ARDL) with break point method outcome demonstrates the positive effect of non-renewable type of energy on CO 2 emissions consumption. On the contrary, the results reveal an insignificant effect of renewable energy on environment improvement. Moreover, the results accept the existence of EKC hypothesis but the highest gross domestic product value in logarithm scale of our data is inferior to the estimated turning point. Consequently, policy-makers in Algeria should expand the ratio of renewable energy and should decrease the quota of non-renewable energy consumption.

  6. Effect of Solid to Liquid Ratio on Heavy Metal Removal by Geopolymer-Based Adsorbent

    NASA Astrophysics Data System (ADS)

    Ariffin, N.; Abdullah, M. M. A. B.; Arif Zainol, M. R. R. Mohd; Baltatu, M. S.; Jamaludin, L.

    2018-06-01

    Microstructure of three-dimensional aluminosilicate which similar to zeolite cause geopolymer based adsorbent accepted in the treatment of wastewater. This paper presents an investigation on the copper removal from the wastewater by varying the solid to liquid ratio in the fly ash, kaolin and sludge-based geopolymer adsorbent. The adsorption test was conducted to study the efficiency of the adsorbent and the copper concentration was examined by using Atomic Adsorption Spectrometry (AAS). The optimum solid to liquid ratio with the highest percentage removal were 1.0, 0.5 and 0.8 for fly ash-based geopolymer, kaolin-based geopolymer and sludge-based geopolymer adsorbent.

  7. The use of sustainable materials for quick repair of aging bridges : phase II final report.

    DOT National Transportation Integrated Search

    2012-02-01

    "During the last decade fiber reinforced polymer (FRP) materials have gained wide acceptance for repair and strengthening of existing infrastructures or to design new infrastructures due to their desirable properties (high strength to weight ratio, l...

  8. 34 CFR 668.172 - Financial ratios.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... effect of changes in accounting principles, and the effect of changes in accounting estimates; (2) May... marketing costs; (3) Excludes all unsecured or uncollateralized related-party receivables; (4) Excludes all intangible assets defined as intangible in accordance with generally accepted accounting principles; and (5...

  9. Tests Of A Stirling-Engine Power Converter

    NASA Technical Reports Server (NTRS)

    Dochat, George

    1995-01-01

    Report describes acceptance tests of power converter consisting of pair of opposed free-piston Stirling engines driving linear alternators. Stirling engines offer potential for extremely long life, high reliability, high efficiency at low hot-to-cold temperature ratios, and relatively low heater-head temperatures.

  10. Continuous Subcutaneous Insulin Infusion as an Effective Method of Desensitization Therapy for Diabetic Patients with Insulin Allergy: A 4-year Single-center Experience.

    PubMed

    Yuan, Tao; Zhao, Weigang; Wang, Lianglu; Dong, Yingyue; Li, Naishi

    2016-11-01

    This article summarizes our experiences in the application of continuous subcutaneous insulin infusion (CSII) as a method of rapid desensitization therapy for diabetic patients with insulin allergy that was subsequently switched to a regimen of multiple-dose injections for long-term insulin therapy. The clinical data of 11 diabetic patients with insulin allergy in Peking Union Medical College Hospital from April 1, 2008, through December 31, 2011, were retrospectively analyzed. All 11 conditions were diagnosed by case history, skin testing, determination of serum specific anti-insulin IgE, and reaction to withdrawal of insulin. Seven patients accepted the traditional injection method of desensitization, and 5 patients accepted CSII with the protocol designed for this study (1 patient accepted CSII after failure by the formal method). Six of the 7 patients who accepted the traditional method and all 5 patients who accepted CSII had successful results. All 5 patients in the CSII group switched to a regimen of multiple dosage injections. In a survey of 28 nurses, both experienced nurses and practical nurses preferred to use CSII as the method of desensitization. It is feasible and effective for diabetic patients with insulin allergy to use CSII as a method of rapid desensitization with subsequent switching to a regimen of multiple-dose injections for long-term insulin therapy. Copyright © 2016 Elsevier HS Journals, Inc. All rights reserved.

  11. A study of the user's perception of economic value in nursing visits to primary care by the method of contingent valuation.

    PubMed

    Martín-Fernández, Jesús; Pérez-Rivas, Francisco Javier; Gómez-Gascón, Tomás; del Cura-González, Isabel; Tello Bernabé, Eugenia; Rodríguez-Martínez, Gemma; Polentinos-Castro, Elena; Domínguez-Bidagor, Julia; Ariza-Cardiel, Gloria; Conde-López, Juan Francisco; Beamud-Lagos, Milagros; Aguado-Arroyo, Oscar; Sanz-Bayona, Teresa; Gil-Lacruz, Ana Isabel

    2011-10-03

    The identification of the attribution of economic value that users of a health system assign to a health service could be useful in planning these services. The method of contingent valuation can provide information about the user's perception of value in monetary terms, and therefore comparable between services of a very different nature. This study attempts to extract the economic value that the subject, user of primary care nursing services in a public health system, attributes to this service by the method of contingent valuation, based on the perspectives of Willingness to Pay (WTP) and Willingness to Accept [Compensation] (WTA). This is an economic study with a transversal design. The contingent valuation method will be used to estimate the user's willingness to pay (WTP) for the care received from the primary care nurse and the willingness to accept [compensation] (WTA), were this service eliminated. A survey that meets the requisites of the contingent valuation method will be constructed and pilot-tested. Subsequently, 600 interviews will be performed with subjects chosen by systematic randomized sampling from among those who visit nursing at twenty health centers with different socioeconomic characteristics in the Community of Madrid. The characteristics of the subject and of the care received that can explain the variations in WTP, WTA and in the WTP/WTA ratio expressed will be studied. A theoretical validation of contingent valuation will be performed constructing two explanatory multivariate mixed models in which the dependent variable will be WTP, and the WTP/WTA relationship, respectively. The identification of the attribution of economic value to a health service that does not have a direct price at the time of use, such as a visit to primary care nursing, and the definition of a profile of "loss aversion" in reference to the service evaluated, can be relevant elements in planning, enabling incorporating patient preferences to health policy decision-making.

  12. General Performance Calculations for Gas Turbine Engines

    DTIC Science & Technology

    1946-08-01

    by - D. H. Mailing on. B.So. June, 1946. In this monograph an attempt in made to summarise the theoretical work carried out during the past few...Engines 1.0 nBBPDPCTION ir’-> During the war years the gas turbine may be said to have come into its own, both as an engine already accepted and...The closer this second pressure ratio is to 1 the lower is the mnxlnwm output and also the pressure ratio r.t which that maximum occurs. Tho

  13. Acceptability of formulations and application methods for vaginal microbicides among drug-involved women: results of product trials in three cities.

    PubMed

    Hammett, T M; Mason, T H; Joanis, C L; Foster, S E; Harmon, P; Robles, R R; Finlinson, H A; Feudo, R; Vining-Bethea, S; Jeter, G; Mayer, K H; Doherty-Iddings, P; Seage, G R

    2000-02-01

    Female-controlled methods of HIV prevention, such as vaginal microbicides, are urgently needed, particularly among drug-involved women. Acceptability research is critical to product development. To assess the acceptability of forms and application methods for future microbicides. Eighty-four drug-involved women were introduced in groups to three lubricant products, asked to try each for 3 weeks, and scheduled for individual follow-up interviews. Participants and their partners felt positive about the products, and expressed willingness to use microbicides if they were shown to be effective against HIV. Women agreed on product characteristics that influenced their reactions (e.g. ease of insertion, degree of "messiness"), but often disagreed on whether their reactions to these characteristics were positive or negative. Development of acceptable and effective HIV-prevention products depends on understanding the interaction between characteristics of the products and the characteristics and perceptions of women. Levels of sexual risk and acceptability factors based on drug-use patterns, race and ethnicity, culture, age, and types and attitudes of male partners suggest that a "one size fits all" approach will not win broad acceptance among drug-involved women.

  14. Improved sample utilization in thermal ionization mass spectrometry isotope ratio measurements: refined development of porous ion emitters for nuclear forensic applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baruzzini, Matthew Louis

    The precise and accurate determination of isotopic composition in nuclear forensic samples is vital for assessing origin, intended use and process history. Thermal ionization mass spectrometry (TIMS) is widely accepted as the gold standard for high performance isotopic measurements and has long served as the workhorse in the isotopic ratio determination of nuclear materials. Nuclear forensic and safeguard specialists have relied heavily on such methods for both routine and atypical e orts. Despite widespread use, TIMS methods for the assay of actinide systems continue to be hindered by poor ionization e ciency, often less than tenths of a percent; themore » majority of a sample is not measured. This represents a growing challenge in addressing nextgeneration nuclear detection needs by limiting the ability to analyze ultratrace quantities of high priority elements that could potentially provide critical nuclear forensic signatures. Porous ion emitter (PIE) thermal ion sources were developed in response to the growing need for new TIMS ion source strategies for improved ionization e ciency, PIEs have proven to be simple to implement, straightforward approach to boosting ion yield. This work serves to expand the use of PIE techniques for the analysis of trace quantities of plutonium and americium. PIEs exhibited superior plutonium and americium ion yields when compared to direct lament loading and the resin bead technique, one of the most e cient methods for actinide analysis, at similar mass loading levels. Initial attempts at altering PIE composition for the analysis of plutonium proved to enhance sample utilization even further. Preliminary investigations of the instrumental fractionation behavior of plutonium and uranium analyzed via PIE methods were conducted. Data collected during these initial trial indicate that PIEs fractionate in a consistent, reproducible manner; a necessity for high precision isotope ratio measurements. Ultimately, PIEs methods were applied for the age determination of various uranium isotopic standards. PIEs did not exhibit signi cant advantages for the determination of model ages when compared to traditional laments; however, this trial was able to provide valuable insight for guiding future investigations.« less

  15. Methodology Used to Assess Acceptability of Oral Pediatric Medicines: A Systematic Literature Search and Narrative Review.

    PubMed

    Mistry, Punam; Batchelor, Hannah

    2017-06-01

    Regulatory guidelines require that any new medicine designed for a pediatric population must be demonstrated as being acceptable to that population. There is currently no guidance on how to conduct or report on acceptability testing. Our objective was to undertake a review of the methods used to assess the acceptability of medicines within a pediatric population and use this review to propose the most appropriate methodology. We used a defined search strategy to identify literature reports of acceptability assessments of medicines conducted within pediatric populations and extracted information about the tools used in these studies for comparison across studies. In total, 61 articles were included in the analysis. Palatability was the most common (54/61) attribute measured when evaluating acceptability. Simple scale methods were most commonly used, with visual analog scales (VAS) and hedonic scales used both separately and in combination in 34 of the 61 studies. Hedonic scales alone were used in 14 studies and VAS alone in just five studies. Other tools included Likert scales; forced choice or preference; surveys or questionnaires; observations of facial expressions during administration, ease of swallowing, or ability to swallow the dosage; prevalence of complaints or refusal to take the medicine; and time taken for a nurse to administer the medicine. The best scale in terms of validity, reliability, feasibility, and preference to use when assessing acceptability remains unclear. Further work is required to select the most appropriate method to justify whether a medicine is acceptable to a pediatric population.

  16. Acceptance and purchase intent of US consumers for nonwheat rice butter cakes.

    PubMed

    Sae-Eaw, A; Chompreeda, P; Prinyawiwatkul, W; Haruthaithanasan, V; Suwonsichon, T; Saidu, J E; Xu, Z

    2007-03-01

    This study evaluated consumer acceptance and purchase intent of nonwheat butter cake formulations prepared with Thai jasmine rice flour. Three nonwheat rice butter cakes were prepared with varying amounts of powdered emulsifier (propylene glycol ester:diacetyl tartaric acid ester of monoglyceride, 8:2) at 0% (product A), 7.5% (product B), and 15% (product C) of the margarine content (15%) in the cake formulation. A commercial wheat-based butter cake served as the control. Consumers (n= 400) evaluated acceptability of 9 sensory attributes using a 9-point hedonic scale. Overall acceptance and purchase intent were determined with a binomial (yes/no) scale. At least 81% of consumers accepted products B and C, of which 42.1% and 47%, respectively, would purchase the products if commercially available. Product A was neither liked nor disliked with an overall liking score of 5.39. The butter cake products were differentiated by textural acceptability (overall texture, softness, and moistness) with a canonical correlation of 0.71 to 0.79. Overall liking and taste influenced overall acceptance and purchase intent. Odor influenced purchase intent (P= 0.0014), but not overall acceptance. The odds ratio of overall liking was 3.462 for purchase intent, indicating the probability of the product being purchased is 3.462 times higher (than not being purchased, P < 0.0001) with every 1-unit increase of the overall liking score. Based on the logit model, overall acceptance and purchase intent could be predicted with 89.3% and 83.3% accuracy, respectively. The study demonstrated feasibility of completely substituting wheat flour with Thai jasmine rice flour for production of butter cake products acceptable to American consumers.

  17. Comparison of Saliva Collection Methods in Children with High-Functioning Autism Spectrum Disorders: Acceptability and Recovery of Cortisol

    ERIC Educational Resources Information Center

    Putnam, Susan K.; Lopata, Christopher; Fox, Jeffery D.; Thomeer, Marcus L.; Rodgers, Jonathan D.; Volker, Martin A.; Lee, Gloria K.; Neilans, Erik G.; Werth, Jilynn

    2012-01-01

    This study compared cortisol concentrations yielded using three saliva collection methods (passive drool, salivette, and sorbette) in both in vitro and in vivo conditions, as well as method acceptability for a sample of children (n = 39) with High Functioning Autism Spectrum Disorders. No cortisol concentration differences were observed between…

  18. Pharmacokinetics of lacosamide and omeprazole coadministration in healthy volunteers: results from a phase I, randomized, crossover trial.

    PubMed

    Cawello, Willi; Mueller-Voessing, Christa; Fichtner, Andreas

    2014-05-01

    The antiepileptic drug lacosamide has a low potential for drug-drug interactions, but is a substrate and moderate inhibitor of the cytochrome P450 (CYP) enzyme CYP2C19. This phase I, randomized, open-label, two-way crossover trial evaluated the pharmacokinetic effects of lacosamide and omeprazole coadministration. Healthy, White, male volunteers (n = 36) who were not poor metabolizers of CYP2C19 were randomized to treatment A (single-dose 40 mg omeprazole on days 1 and 8 together with 6 days of multiple-dose lacosamide [200-600 mg/day] on days 3-8) and treatment B (single doses of 300 mg lacosamide on days 1 and 8 with 7 days of 40 mg/day omeprazole on days 3-9) in pseudorandom order, separated by a ≥ 7-day washout period. Area under the concentration-time curve (AUC) and peak concentration (C(max)) were the primary pharmacokinetic parameters measured for lacosamide or omeprazole administered alone (reference) or in combination (test). Bioequivalence was determined if the 90 % confidence interval (CI) of the ratio (test/reference) fell within the acceptance range of 0.8-1.25. The point estimates (90 % CI) of the ratio of omeprazole + lacosamide coadministered versus omeprazole alone for AUC (1.098 [0.996-1.209]) and C(max) (1.105 [0.979-1.247]) fell within the acceptance range for bioequivalence. The point estimates (90 % CI) of the ratio of lacosamide + omeprazole coadministration versus lacosamide alone also fell within the acceptance range for bioequivalence (AUC 1.133 [1.102-1.165]); C(max) 0.996 (0.947-1.047). Steady-state lacosamide did not influence omeprazole single-dose pharmacokinetics, and multiple-dose omeprazole did not influence lacosamide single-dose pharmacokinetics.

  19. Is there a kink in consumers' threshold value for cost-effectiveness in health care?

    PubMed

    O'Brien, Bernie J; Gertsen, Kirsten; Willan, Andrew R; Faulkner, Lisa A

    2002-03-01

    A reproducible observation is that consumers' willingness-to-accept (WTA) monetary compensation to forgo a program is greater than their stated willingness-to-pay (WTP) for the same benefit. Several explanations exist, including the psychological principle that the utility of losses weighs heavier than gains. We sought to quantify the WTP-WTA disparity from published literature and explore implications for cost-effectiveness analysis accept-reject thresholds in the south-west quadrant of the cost-effectiveness plane (less effect, less cost). We reviewed published studies (health and non-health) to estimate the ratio of WTA to WTP for the same program benefit for each study and to determine if WTA is consistently greater than WTP in the literature. WTA/WTP ratios were greater than unity for every study we reviewed. The ratios ranged from 3.2 to 89.4 for environmental studies (n=7), 1.9 to 6.4 for health care studies (n=2), 1.1 to 3.6 for safety studies (n=4) and 1.3 to 2.6 for experimental studies (n=7). Given that WTA is greater than WTP based on individual preferences, should not societal preferences used to determine cost-effectiveness thresholds reflect this disparity? Current convention in cost-effectiveness analysis is that any given accept-rejection criterion (e.g. $50 k/QALY gained) is symmetric - a straight line through the origin of the cost-effectiveness plane. The WTA-WTP evidence suggests a downward 'kink' through the origin for the south-west quadrant, such that the 'selling price' of a QALY is greater than the 'buying price'. The possibility of 'kinky cost-effectiveness' decision rules and the size of the kink merits further exploration. Copyright 2002 John Wiley & Sons, Ltd.

  20. Optimization of food materials for development of nutritious pasta utilizing groundnut meal and beetroot.

    PubMed

    Mridula, D; Gupta, R K; Bhadwal, Sheetal; Khaira, Harjot; Tyagi, S K

    2016-04-01

    Present study was undertaken to optimize the level of food materials viz. groundnut meal, beetroot juice and refined wheat flour for development of nutritious pasta using response surface methodology. Box-benken design of experiments was used to design different experimental combinations considering 10 to 20 g groundnut meal, 6 to 18 mL beetroot juice and 80 to 90 g refined wheat flour. Quality attributes such as protein content, antioxidant activity, colour, cooking quality (solid loss, rehydration ratio and cooking time) and sensory acceptability of pasta samples were the dependent variables for the study. The results revealed that pasta samples with higher levels of groundnut meal and beetroot juice were high in antioxidant activity and overall sensory acceptability. The samples with higher content of groundnut meal indicated higher protein contents in them. On the other hand, the samples with higher beetroot juice content were high in rehydration ratio and lesser cooking time along with low solid loss in cooking water. The different level of studied food materials significantly affected the colour quality of pasta samples. Optimized combination for development of nutritious pasta consisted of 20 g groundnut meal, 18 mL beetroot juice and 83.49 g refined wheat flour with overall desirability as 0.905. This pasta sample required 5.5 min to cook and showed 1.37 % solid loss and rehydration ratio as 6.28. Pasta sample prepared following optimized formulation provided 19.56 % protein content, 23.95 % antioxidant activity and 125.89 mg/100 g total phenols with overall sensory acceptability scores 8.71.

  1. Technical note: Alternatives to reduce adipose tissue sampling bias.

    PubMed

    Cruz, G D; Wang, Y; Fadel, J G

    2014-10-01

    Understanding the mechanisms by which nutritional and pharmaceutical factors can manipulate adipose tissue growth and development in production animals has direct and indirect effects in the profitability of an enterprise. Adipocyte cellularity (number and size) is a key biological response that is commonly measured in animal science research. The variability and sampling of adipocyte cellularity within a muscle has been addressed in previous studies, but no attempt to critically investigate these issues has been proposed in the literature. The present study evaluated 2 sampling techniques (random and systematic) in an attempt to minimize sampling bias and to determine the minimum number of samples from 1 to 15 needed to represent the overall adipose tissue in the muscle. Both sampling procedures were applied on adipose tissue samples dissected from 30 longissimus muscles from cattle finished either on grass or grain. Briefly, adipose tissue samples were fixed with osmium tetroxide, and size and number of adipocytes were determined by a Coulter Counter. These results were then fit in a finite mixture model to obtain distribution parameters of each sample. To evaluate the benefits of increasing number of samples and the advantage of the new sampling technique, the concept of acceptance ratio was used; simply stated, the higher the acceptance ratio, the better the representation of the overall population. As expected, a great improvement on the estimation of the overall adipocyte cellularity parameters was observed using both sampling techniques when sample size number increased from 1 to 15 samples, considering both techniques' acceptance ratio increased from approximately 3 to 25%. When comparing sampling techniques, the systematic procedure slightly improved parameters estimation. The results suggest that more detailed research using other sampling techniques may provide better estimates for minimum sampling.

  2. Photographic Method For Measurement Of Image Intensifier Tube Contrast

    NASA Astrophysics Data System (ADS)

    Moore, Robert J.

    1981-07-01

    An important parameter in an image intensifier-based imaging system is the contrast of the image intensifier tube itself. This paper presents a photographic method for the measurement of the large-scale contrast of an image intensifier tube at the system level which can be performed in the clinical setting with equipment normally found in a modern Radiology Department. A strip of Lead is positioned on-center at the bottom of the grid so that a line image of 100% contrast will be presented to the input phosphor of the image intensifier when the x-ray tube is energized at low kilovoltage. The output phosphor is photographed either with an existing fluorographic camera (photospot or cine) on the imaging tower, or with a 35-mm SLR camera loaded with orthochromatic cine film through the collimating lens of the system from the position normally occupied by the television camera, during fluoroscopy, if no other camera is present on the imaging tower. The resultant on-frame optical density is measured with a densitometer in the central part of the developed frame adjacent to and behind the image of the Lead strip. These optical density readings are converted into a ratio of light intensities from the corresponding regions on the output phosphor using the characteristic curve for the type of film employed, which is obtained by means of light sensitometry. The percent contrast is then calculated from (ratio of intensities - 1)/(ratio of intensities + 1)) X 100. Using data for a variety of CsI image intensifiers used for both gastrointestinal and vascular studies, the method is shown to give measured percent contrasts with a reproducibility of no worse than-2%, independent of type of camera used or type of sensitometer used. Standards of acceptable performance based on the author's experience with this technique over the past five years are presented for systems designed for Barium studies and for systems designed for Iodine studies. The relationship between the percent contrast as defined here, the veiling glare as defined by Siedband, and the contrast ratio as normally defined is discussed, as well as the relevance of large-scale contrast of an image intensifier tube.

  3. Modern contraceptive utilization and associated factors among married pastoralist women in Bale eco-region, Bale Zone, South East Ethiopia.

    PubMed

    Belda, Semere Sileshi; Haile, Mekonnen Tegegne; Melku, Abulie Takele; Tololu, Abdurehaman Kalu

    2017-03-14

    Women who live in remote rural areas encounter different challenges against contraception and often deny the use of modern contraceptive methods. The predictors of modern contraceptive utilization by pastoralist women in the Bale eco-region could be specific and are not well known. Therefore, this study aims to assess modern contraceptive utilization and its determinants among married pastoralist women in Bale eco-region, Oromia regional state, South East Ethiopia. A community-based cross-sectional study was conducted from 20th November 2015 to 30th February 2016. A structured questionnaire was used to interview 549 married pastoralist women who were selected by multistage sampling technique. The data were analyzed by SPSS - 21 software, multivariate logistic regression analysis was used to identify predictors of modern contraceptive use at (P-value <0.05), and odds ratios with 95% confidence interval were used to assess the strength of associations between variables. The current modern contraceptive method use by married pastoralist women was (20.8%). Among the total users, (78.1%) use the injectable method. The common reasons for non-use of modern contraceptive methods includes: religious-opposition (55.9%), desire for more children (28.3%), fear of side effects (25.5%), and husband's opposition (17.5%). Couple discussion (AOR = 4.63, 95%CI: 2.15, 9.98), perceived husband's approval (AOR = 8.00, 95% CI: 3.52, 18.19), discussion with health extension worker (AOR = 5.99, 95% CI: 1.81, 19.85), and perceived cultural acceptability (AOR = 2.10, 95% CI: 1.09, 4.03) were the independent predictors of modern contraceptive use by married pastoralist women in Bale eco-region. The study identified lower modern contraceptive method utilization by pastoralist women, and the majority of the contraceptive users rely on short- acting contraceptive methods. The uncomplimentary perceptions towards religious and cultural acceptability of modern contraceptive method were among the major reasons for lesser utilization of the methods. Family planning programs should be tailored to actively involve pastoralist women, husbands, and religious leaders in pastoralist communities.

  4. Simple and efficient liposomal encapsulation of topotecan by ammonium sulfate gradient: stability, pharmacokinetic and therapeutic evaluation.

    PubMed

    Liu, Jun-Jen; Hong, Ruey-Long; Cheng, Wen-Fang; Hong, Keelung; Chang, Fu-Hsiung; Tseng, Yun-Long

    2002-08-01

    Topotecan (TPT), a topoisomerase I inhibitor, is presently undergoing clinical evaluation worldwide. Previous studies have shown that entrapping TPT within multi-lamellar vesicle liposome can stabilize the lactone moiety, which is structurally important for biological activity. However, low drug:lipid ratios due to the amphipathic character and small entrapment volume in the unilamellar vesicle limits the development of pharmaceutically acceptable liposomal formulation. With an aim to improve on this drawback, we herein describe a method that utilizes the ammonium sulfate gradient to entrap TPT into liposomes. By this method, the encapsulation efficiency was over 90% and a drug:lipid molar ratio as high as 1:5.4 was reached. In comparison with free drug, liposome-encapsulated TPT is more stable in physiological conditions and shows higher in vitro cytotoxicity. Because of increased blood circulation time, the initial plasma concentration and area under the plasma concentration of liposomal drugs were 14 and 40 times, respectively, of those of free drug. Furthermore, liposome encapsulation enhanced the antitumor activity of TPT in syngeneic murine C-26 and human HTB-9 xenograft models in vivo. At a dose of 5 mg/kg, the tumor growth delay of liposomal formulation was significantly than that of free TPT. Based on these results, we believe that this liposomal TPT formulation is worthy of further clinical study. Copyright 2002 Lippincott Williams & Wilkins.

  5. Fabrication and Properties of Micro-Nanoencapsulated Phase Change Materials for Internally-Cooled Liquid Desiccant Dehumidification.

    PubMed

    Niu, Xiaofeng; Xu, Qing; Zhang, Yi; Zhang, Yue; Yan, Yufeng; Liu, Tao

    2017-04-29

    Micro-nanoencapsulated phase change materials (M-NEPCMs) are proposed to be useful in liquid desiccant dehumidification by restraining the temperature rise in the moisture-removal process and improving the dehumidification efficiency. In this paper, the n -octadecane M-NEPCMs with desirable thermal properties for internally-cooled dehumidification were fabricated by using compound emulsifiers through the in-situ polymerization method. Melamine-formaldehyde resin was used as the shell material. The effects of the mixing ratio, emulsification methods and amount of the compound emulsifiers on the morphology, size and thermal properties of the M-NEPCMs were investigated experimentally. The optimum weight mixing ratio of the compound emulsifiers is SDS (sodium dodecyl sulfate):Tween80 (polyoxyethylene sorbitan monooleate):Span80 (sorbitan monooleate) = 0.1:0.6:0.3, which achieves the best stability of the n -octadecane emulsion. When the compound emulsifiers are 10 wt. % of the core material, the melting enthalpy of M-NEPCMs reaches its maximum of 145.26 J/g of capsules, with an encapsulation efficiency of 62.88% and a mean diameter of 636 nm. The sub-cooling of the prepared M-NEPCMs is lower than 3 °C, with an acceptable thermal reliability after the thermal cycling test. A pre-emulsification prior to the addition of deionized water in the emulsification is beneficial to the morphology of the capsules, as the phase change enthalpy can be increased by 123.7%.

  6. Excited-state dissociation dynamics of phenol studied by a new time-resolved technique

    NASA Astrophysics Data System (ADS)

    Lin, Yen-Cheng; Lee, Chin; Lee, Shih-Huang; Lee, Yin-Yu; Lee, Yuan T.; Tseng, Chien-Ming; Ni, Chi-Kung

    2018-02-01

    Phenol is an important model molecule for the theoretical and experimental investigation of dissociation in the multistate potential energy surfaces. Recent theoretical calculations [X. Xu et al., J. Am. Chem. Soc. 136, 16378 (2014)] suggest that the phenoxyl radical produced in both the X and A states from the O-H bond fission in phenol can contribute substantially to the slow component of photofragment translational energy distribution. However, current experimental techniques struggle to separate the contributions from different dissociation pathways. A new type of time-resolved pump-probe experiment is described that enables the selection of the products generated from a specific time window after molecules are excited by a pump laser pulse and can quantitatively characterize the translational energy distribution and branching ratio of each dissociation pathway. This method modifies conventional photofragment translational spectroscopy by reducing the acceptance angles of the detection region and changing the interaction region of the pump laser beam and the molecular beam along the molecular beam axis. The translational energy distributions and branching ratios of the phenoxyl radicals produced in the X, A, and B states from the photodissociation of phenol at 213 and 193 nm are reported. Unlike other techniques, this method has no interference from the undissociated hot molecules. It can ultimately become a standard pump-probe technique for the study of large molecule photodissociation in multistates.

  7. Sensory quality of broiler breast meat influenced by low atmospheric pressure stunning, deboning time and cooking methods.

    PubMed

    Schilling, M W; Radhakrishnan, V; Vizzier-Thaxton, Y; Christensen, K; Williams, J B; Joseph, P

    2015-06-01

    Stunning method (low atmospheric pressure stunning, LAPS and electrical stunning, ES), deboning time (0.75 h and 4 h), and cooking method (baking, frying, and sous vide) were evaluated for their impact on the descriptive sensory characteristics and consumer acceptability of breast meat (n=576, 144 birds per stunning × deboning time combination). Sensory evaluation was conducted by trained descriptive (n=8) and consumer (n=185) panels. On average, no differences (P>0.05) existed in the sensory acceptability of fried and sous vide cooked broiler breast treatment combinations. However, for oven-baking, the LAPS treatment that was deboned at 4 h was more acceptable (P<0.05) than other treatments and the ES and LAPS 4 h samples had greater (P<0.05) acceptability for texture than their ES and LAPS 0.75 h counterparts. Since consumers were highly variable in their liking of chicken breast treatments, consumers were grouped into clusters for each cooking method based on liking and preference. Cluster analysis data revealed that the largest groups of consumers liked (score≥6.0) all chicken breast treatments, but a larger proportion of consumers liked the 4 h LAPS and ES treatments when compared to the 0.75 h LAPS and ES treatments for all cooking methods. In addition, the consumers who indicated that baked chicken breast was highly acceptable preferred (P<0.05) 4 h LAPS over the 4 h ES samples. Based on sensory results, chicken breast meat from all stunning and deboning method combinations was highly acceptable to the majority of consumers, but the LAPS 4 h treatment had enhanced sensory characteristics when baked. © 2015 Poultry Science Association Inc.

  8. Rapid determination of total protein and wet gluten in commercial wheat flour using siSVR-NIR.

    PubMed

    Chen, Jia; Zhu, Shipin; Zhao, Guohua

    2017-04-15

    The determination of total protein and wet gluten is of critical importance when screening commercial flour for desired processing suitability. To this end, a near-infrared spectroscopy (NIR) method with support vector regression was developed in the present study. The effects of spectral preprocessing and the synergy interval on model performance were investigated. The results showed that the models from raw spectra were not acceptable, but they were substantially improved by properly applying spectral preprocessing methods. Meanwhile, the synergy interval was validated with a good ability to improve the performance of models based on the whole spectrum. The coefficient of determination (R 2 ), the root mean square error of prediction (RMSEP) and the standard deviation ratio (SDR) of the best models for total protein (wet gluten) were 0.906 (0.850), 0.425 (1.024) and 3.065 (2.482), respectively. These two best models have similar and lower relative errors (approximately 8.8%), which indicates their feasibility. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Analysis of tractable distortion metrics for EEG compression applications.

    PubMed

    Bazán-Prieto, Carlos; Blanco-Velasco, Manuel; Cárdenas-Barrera, Julián; Cruz-Roldán, Fernando

    2012-07-01

    Coding distortion in lossy electroencephalographic (EEG) signal compression methods is evaluated through tractable objective criteria. The percentage root-mean-square difference, which is a global and relative indicator of the quality held by reconstructed waveforms, is the most widely used criterion. However, this parameter does not ensure compliance with clinical standard guidelines that specify limits to allowable noise in EEG recordings. As a result, expert clinicians may have difficulties interpreting the resulting distortion of the EEG for a given value of this parameter. Conversely, the root-mean-square error is an alternative criterion that quantifies distortion in understandable units. In this paper, we demonstrate that the root-mean-square error is better suited to control and to assess the distortion introduced by compression methods. The experiments conducted in this paper show that the use of the root-mean-square error as target parameter in EEG compression allows both clinicians and scientists to infer whether coding error is clinically acceptable or not at no cost for the compression ratio.

  10. [Technology of composting].

    PubMed

    Jäger, B

    1983-09-01

    The technology of composting must guarantee the material-chemical, biological and physical-technical reaction conditions essential for the rotting process. In this, the constituents of the input material and the C/N ratio play an important role. Maintaining optimum decomposition conditions is rendered difficult by the fact that the physical-technical reaction parameters partly exclude each other. These are: optimum humidity, adequate air/oxygen supply, large active surface, loose structure with sufficient decomposition volume. The processing of the raw refuse required to maintain the physical-technical reaction parameters can be carried out either by the conventional method of preliminary fragmentizing, sieving and mixing or else in conjunction with separating recycling in adapted systems. The latter procedure obviates some drawbacks which mainly result from the high expenditure required for preliminary fragmentation of the raw refuse. Moreover, presorting affords the possibility of reducing the heavy-metal content of the organic composing fraction and this approaches a solution to the noxa disposal problem which at present stands in the way of being accepted as an ecological waste disposal method.

  11. A threshold method for immunological correlates of protection

    PubMed Central

    2013-01-01

    Background Immunological correlates of protection are biological markers such as disease-specific antibodies which correlate with protection against disease and which are measurable with immunological assays. It is common in vaccine research and in setting immunization policy to rely on threshold values for the correlate where the accepted threshold differentiates between individuals who are considered to be protected against disease and those who are susceptible. Examples where thresholds are used include development of a new generation 13-valent pneumococcal conjugate vaccine which was required in clinical trials to meet accepted thresholds for the older 7-valent vaccine, and public health decision making on vaccination policy based on long-term maintenance of protective thresholds for Hepatitis A, rubella, measles, Japanese encephalitis and others. Despite widespread use of such thresholds in vaccine policy and research, few statistical approaches have been formally developed which specifically incorporate a threshold parameter in order to estimate the value of the protective threshold from data. Methods We propose a 3-parameter statistical model called the a:b model which incorporates parameters for a threshold and constant but different infection probabilities below and above the threshold estimated using profile likelihood or least squares methods. Evaluation of the estimated threshold can be performed by a significance test for the existence of a threshold using a modified likelihood ratio test which follows a chi-squared distribution with 3 degrees of freedom, and confidence intervals for the threshold can be obtained by bootstrapping. The model also permits assessment of relative risk of infection in patients achieving the threshold or not. Goodness-of-fit of the a:b model may be assessed using the Hosmer-Lemeshow approach. The model is applied to 15 datasets from published clinical trials on pertussis, respiratory syncytial virus and varicella. Results Highly significant thresholds with p-values less than 0.01 were found for 13 of the 15 datasets. Considerable variability was seen in the widths of confidence intervals. Relative risks indicated around 70% or better protection in 11 datasets and relevance of the estimated threshold to imply strong protection. Goodness-of-fit was generally acceptable. Conclusions The a:b model offers a formal statistical method of estimation of thresholds differentiating susceptible from protected individuals which has previously depended on putative statements based on visual inspection of data. PMID:23448322

  12. Validation of the portable Air-Smart Spirometer

    PubMed Central

    Núñez Fernández, Marta; Pallares Sanmartín, Abel; Mouronte Roibas, Cecilia; Cerdeira Domínguez, Luz; Botana Rial, Maria Isabel; Blanco Cid, Nagore; Fernández Villar, Alberto

    2018-01-01

    Background The Air-Smart Spirometer is the first portable device accepted by the European Community (EC) that performs spirometric measurements by a turbine mechanism and displays the results on a smartphone or a tablet. Methods In this multicenter, descriptive and cross-sectional prospective study carried out in 2 hospital centers, we compare FEV1, FVC, FEV1/FVC ratio measured with the Air Smart-Spirometer device and a conventional spirometer, and analyze the ability of this new portable device to detect obstructions. Patients were included for 2 consecutive months. We calculate sensitivity, specificity, positive and negative predictive value (PPV and NPV) and likelihood ratio (LR +, LR-) as well as the Kappa Index to evaluate the concordance between the two devices for the detection of obstruction. The agreement and relation between the values of FEV1 and FVC in absolute value and the FEV1/FVC ratio measured by both devices were analyzed by calculating the intraclass correlation coefficient (ICC) and the Pearson correlation coefficient (r) respectively. Results 200 patients (100 from each center) were included with a mean age of 57 (± 14) years, 110 were men (55%). Obstruction was detected by conventional spirometry in 73 patients (40.1%). Using a FEV1/FVC ratio smaller than 0.7 to detect obstruction with the Air Smart-Spirometer, the kappa index was 0.88, sensitivity (90.4%), specificity (97.2%), PPV (95.7%), NPV (93.7%), positive likelihood ratio (32.29), and negative likelihood ratio (0.10). The ICC and r between FEV1, FVC, and FEV1 / FVC ratio measured by the Air Smart Spirometer and the conventional spirometer were all higher than 0.94. Conclusion The Air-Smart Spirometer is a simple and very precise instrument for detecting obstructive airway diseases. It is easy to use, which could make it especially useful non-specialized care and in other areas. PMID:29474502

  13. Acceptability of healthcare interventions: an overview of reviews and development of a theoretical framework.

    PubMed

    Sekhon, Mandeep; Cartwright, Martin; Francis, Jill J

    2017-01-26

    It is increasingly acknowledged that 'acceptability' should be considered when designing, evaluating and implementing healthcare interventions. However, the published literature offers little guidance on how to define or assess acceptability. The purpose of this study was to develop a multi-construct theoretical framework of acceptability of healthcare interventions that can be applied to assess prospective (i.e. anticipated) and retrospective (i.e. experienced) acceptability from the perspective of intervention delivers and recipients. Two methods were used to select the component constructs of acceptability. 1) An overview of reviews was conducted to identify systematic reviews that claim to define, theorise or measure acceptability of healthcare interventions. 2) Principles of inductive and deductive reasoning were applied to theorise the concept of acceptability and develop a theoretical framework. Steps included (1) defining acceptability; (2) describing its properties and scope and (3) identifying component constructs and empirical indicators. From the 43 reviews included in the overview, none explicitly theorised or defined acceptability. Measures used to assess acceptability focused on behaviour (e.g. dropout rates) (23 reviews), affect (i.e. feelings) (5 reviews), cognition (i.e. perceptions) (7 reviews) or a combination of these (8 reviews). From the methods described above we propose a definition: Acceptability is a multi-faceted construct that reflects the extent to which people delivering or receiving a healthcare intervention consider it to be appropriate, based on anticipated or experienced cognitive and emotional responses to the intervention. The theoretical framework of acceptability (TFA) consists of seven component constructs: affective attitude, burden, perceived effectiveness, ethicality, intervention coherence, opportunity costs, and self-efficacy. Despite frequent claims that healthcare interventions have assessed acceptability, it is evident that acceptability research could be more robust. The proposed definition of acceptability and the TFA can inform assessment tools and evaluations of the acceptability of new or existing interventions.

  14. Feasibility, acceptability and clinical utility of the Cultural Formulation Interview: mixed-methods results from the DSM-5 international field trial.

    PubMed

    Lewis-Fernández, Roberto; Aggarwal, Neil Krishan; Lam, Peter C; Galfalvy, Hanga; Weiss, Mitchell G; Kirmayer, Laurence J; Paralikar, Vasudeo; Deshpande, Smita N; Díaz, Esperanza; Nicasio, Andel V; Boiler, Marit; Alarcón, Renato D; Rohlof, Hans; Groen, Simon; van Dijk, Rob C J; Jadhav, Sushrut; Sarmukaddam, Sanjeev; Ndetei, David; Scalco, Monica Z; Bassiri, Kavoos; Aguilar-Gaxiola, Sergio; Ton, Hendry; Westermeyer, Joseph; Vega-Dienstmaier, Johann M

    2017-04-01

    Background There is a need for clinical tools to identify cultural issues in diagnostic assessment. Aims To assess the feasibility, acceptability and clinical utility of the DSM-5 Cultural Formulation Interview (CFI) in routine clinical practice. Method Mixed-methods evaluation of field trial data from six countries. The CFI was administered to diagnostically diverse psychiatric out-patients during a diagnostic interview. In post-evaluation sessions, patients and clinicians completed debriefing qualitative interviews and Likert-scale questionnaires. The duration of CFI administration and the full diagnostic session were monitored. Results Mixed-methods data from 318 patients and 75 clinicians found the CFI feasible, acceptable and useful. Clinician feasibility ratings were significantly lower than patient ratings and other clinician-assessed outcomes. After administering one CFI, however, clinician feasibility ratings improved significantly and subsequent interviews required less time. Conclusions The CFI was included in DSM-5 as a feasible, acceptable and useful cultural assessment tool. © The Royal College of Psychiatrists 2017.

  15. Isotopic and Elemental Determination in Some Romanian Apple Fruit Juices

    PubMed Central

    Magdas, Dana Alina; Dehelean, Adriana; Puscas, Romulus

    2012-01-01

    H, C, O stable isotope ratios and the content of some heavy elements of 31 Romanian single-strength organic apple juices collected from four Transylvanian areas are discussed in this study. The aim of this study was to measure the 2H/1H, 18O/16O, 13C/12C ratios of these juices and their elemental profile and to establish a database of authentic values to be used for adulteration and authenticity testing. Our results have shown mean values of δ 18O = −4.2‰ and δDδ−46.5‰, respectively, for apples from Transylvania and at the same time the mean value of δ 13C = −28.2‰. The content of Cd, Pb, U, Zn, As was below the acceptable limits stipulated in US-EPA standard for drinking water. Cu and Cr limits exceeded for one single juice; Ni content for some apple juices from Maramures, Alba, and Cluj was higher than the acceptable value. PMID:22666164

  16. Extraction, Scrub, and Strip Test Results for the Salt Waste Processing Facility Caustic Side Solvent Extraction Solvent Sample

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, T. B.

    An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D( Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs) measured 12.5, exceeding the required value of 8. This value is consistent with resultsmore » from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges. This revision was created to correct an error. The previous revision used an incorrect set of temperature correction coefficients which resulted in slight deviations from the correct D( Cs) results.« less

  17. Stable isotope signatures and trophic-step fractionation factors of fish tissues collected as non-lethal surrogates of dorsal muscle.

    PubMed

    Busst, Georgina M A; Bašić, Tea; Britton, J Robert

    2015-08-30

    Dorsal white muscle is the standard tissue analysed in fish trophic studies using stable isotope analyses. As muscle is usually collected destructively, fin tissues and scales are often used as non-lethal surrogates; we examined the utility of scales and fin tissue as muscle surrogates. The muscle, fin and scale δ(15) N and δ(13) C values from 10 cyprinid fish species determined with an elemental analyser coupled with an isotope ratio mass spectrometer were compared. The fish comprised (1) samples from the wild, and (2) samples from tank aquaria, using six species held for 120 days and fed a single food resource. Relationships between muscle, fin and scale isotope ratios were examined for each species and for the entire dataset, with the efficacy of four methods of predicting muscle isotope ratios from fin and scale values being tested. The fractionation factors between the three tissues of the laboratory fishes and their food resource were then calculated and applied to Bayesian mixing models to assess their effect on fish diet predictions. The isotopic data of the three tissues per species were distinct, but were significantly related, enabling estimations of muscle values from the two surrogates. Species-specific equations provided the least erroneous corrections of scale and fin isotope ratios (errors < 0.6‰). The fractionation factors for δ(15) N values were in the range obtained for other species, but were often higher for δ(13) C values. Their application to data from two fish populations in the mixing models resulted in significant alterations in diet predictions. Scales and fin tissue are strong surrogates of dorsal muscle in food web studies as they can provide estimates of muscle values within an acceptable level of error when species-specific methods are used. Their derived fractionation factors can also be applied to models predicting fish diet composition from δ(15) N and δ(13) C values. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Forensic analysis of explosives using isotope ratio mass spectrometry (IRMS)--part 1: instrument validation of the DELTAplusXP IRMS for bulk nitrogen isotope ratio measurements.

    PubMed

    Benson, Sarah J; Lennard, Christopher J; Hill, David M; Maynard, Philip; Roux, Claude

    2010-01-01

    A significant amount of research has been conducted into the use of stable isotopes to assist in determining the origin of various materials. The research conducted in the forensic field shows the potential of isotope ratio mass spectrometry (IRMS) to provide a level of discrimination not achievable utilizing traditional forensic techniques. Despite the research there have been few, if any, publications addressing the validation and measurement uncertainty of the technique for forensic applications. This study, the first in a planned series, presents validation data for the measurement of bulk nitrogen isotope ratios in ammonium nitrate (AN) using the DELTA(plus)XP (Thermo Finnigan) IRMS instrument equipped with a ConFlo III interface and FlashEA 1112 elemental analyzer (EA). Appropriate laboratory standards, analytical methods and correction calculations were developed and evaluated. A validation protocol was developed in line with the guidelines provided by the National Association of Testing Authorities, Australia (NATA). Performance characteristics including: accuracy, precision/repeatability, reproducibility/ruggedness, robustness, linear range, and measurement uncertainty were evaluated for the measurement of nitrogen isotope ratios in AN. AN (99.5%) and ammonium thiocyanate (99.99+%) were determined to be the most suitable laboratory standards and were calibrated against international standards (certified reference materials). All performance characteristics were within an acceptable range when potential uncertainties, including the manufacturer's uncertainty of the technique and standards, were taken into account. The experiments described in this article could be used as a model for validation of other instruments for similar purposes. Later studies in this series will address the more general issue of demonstrating that the IRMS technique is scientifically sound and fit-for-purpose in the forensic explosives analysis field.

  19. Volumetric analysis and indocyanine green retention rate at 15 min as predictors of post-hepatectomy liver failure

    PubMed Central

    Kim, Hee Joon; Kim, Choong Young; Park, Eun Kyu; Hur, Young Hoe; Koh, Yang Seok; Kim, Hyun Jong; Cho, Chol Kyoon

    2015-01-01

    Objectives The actual future liver remnant (aFLR) is calculated as the ratio of remnant liver volume (RLV) to total functional liver volume (TFLV). The standardized future liver remnant (sFLR) is calculated as the ratio of RLV to standard liver volume (SLV). The aims of this study were to compare the aFLR with the sFLR and to determine criteria for safe hepatectomy using computed tomography volumetry and indocyanine green retention rate at 15 min (ICG R15). Methods Medical records and volumetric measurements were obtained retrospectively for 81 patients who underwent right hemi-hepatectomy for malignant hepatic tumours from January 2010 to November 2013. The sFLR was compared with the aFLR, and a ratio of sFLR to ICG R15 as a predictor of postoperative hepatic function was established. Results In patients without cirrhosis, the sFLR showed a stronger correlation with the total serum bilirubin level than the aFLR (R2 = 0.499 versus R2 = 0.239). Post-hepatectomy liver failure developed only in the group with an sFLR of <25%, regardless of ICG R15. In patients with cirrhosis, the aFLR and sFLR had no correlation with postoperative total serum bilirubin. An sFLR : ICG R15 ratio of >1.9 showed 66.7% sensitivity and 100% specificity. Conclusions Regardless of ICG R15, an sFLR of ≥25% in patients without cirrhosis, and an sFLR of ≥25% with an sFLR : ICG R15 ratio of >1.9 in patients with cirrhosis indicate acceptable levels of safety in major hepatectomy. PMID:24964188

  20. Negative Public Attitudes Towards Cancer Survivors Returning to Work: A Nationwide Survey in Korea

    PubMed Central

    Shim, Hye-Young; Shin, Ji-Yeon; Kim, Jong Heun; Kim, So-Young; Yang, Hyung-Kook; Park, Jong-Hyock

    2016-01-01

    Purpose Early diagnosis and an improved survival rate have emerged as important issues for cancer survivors returning to work during the prime of their working life. This study investigated the attitudes of the general public towards cancer survivors returning to work in Korea and attempted to identify the factors influencing this negative attitude. Materials and Methods A general public perception survey regarding cancer survivors returning to work, targeting 2,000 individuals between 40-70 years of age, was conducted as face-to-face home visit. Results The public expressed a negative attitude towards cancer survivors returning to work, in terms of both perception and acceptance. Negative perception was higher among those in metropolitan areas compared with urban/rural areas (odds ratio [OR], 1.71), with monthly incomes < $2,000 compared with > $4,000 (OR, 1.54), and with patient care experience compared with those without (OR, 1.41). Negative acceptance was higher among those with monthly incomes < $2,000 compared with > $4,000 (OR, 1.71) and those with patient care experience compared with those without (OR, 1.54). The common factors between acceptance and perception that influenced negative attitude included area of residence, patient care experience, and monthly income. Conclusion This study identified negative attitudes towards cancer survivors returning to work in South Korea and the factors influencing the reintegration of cancer survivors into society. It is necessary to promote community awareness and intervention activities to enable access to community, social, and individual units for the social reintegration of cancer survivors. PMID:26044157

  1. 3D extrusion printing of high drug loading immediate release paracetamol tablets.

    PubMed

    Khaled, Shaban A; Alexander, Morgan R; Wildman, Ricky D; Wallace, Martin J; Sharpe, Sonja; Yoo, Jae; Roberts, Clive J

    2018-03-01

    The manufacture of immediate release high drug loading paracetamol oral tablets was achieved using an extrusion based 3D printer from a premixed water based paste formulation. The 3D printed tablets demonstrate that a very high drug (paracetamol) loading formulation (80% w/w) can be printed as an acceptable tablet using a method suitable for personalisation and distributed manufacture. Paracetamol is an example of a drug whose physical form can present challenges to traditional powder compression tableting. Printing avoids these issues and facilitates the relatively high drug loading. The 3D printed tablets were evaluated for physical and mechanical properties including weight variation, friability, breaking force, disintegration time, and dimensions and were within acceptable range as defined by the international standards stated in the United States Pharmacopoeia (USP). X-ray Powder Diffraction (XRPD) was used to identify the physical form of the active. Additionally, XRPD, Attenuated Total Reflectance Fourier Transform Infrared spectroscopy (ATR-FTIR) and differential scanning calorimetry (DSC) were used to assess possible drug-excipient interactions. The 3D printed tablets were evaluated for drug release using a USP dissolution testing type I apparatus. The tablets showed a profile characteristic of the immediate release profile as intended based upon the active/excipient ratio used with disintegration in less than 60 s and release of most of the drug within 5 min. The results demonstrate the capability of 3D extrusion based printing to produce acceptable high-drug loading tablets from approved materials that comply with current USP standards. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Comparison between two methods for forward calculation of ambient noise H/V spectral ratios

    NASA Astrophysics Data System (ADS)

    Garcia-Jerez, A.; Luzón, F.; Sanchez-Sesma, F. J.; Santoyo, M. A.; Albarello, D.; Lunedei, E.; Campillo, M.; Iturrarán-Viveros, U.

    2011-12-01

    The analysis of horizontal-to-vertical spectral ratios of ambient noise (NHVSR) is a valuable tool for seismic prospecting, particularly if both a dense spatial sampling and a low-cost procedure are required. Unfortunately, the computation method still lacks of a unanimously accepted theoretical basis and different approaches are currently being used for inversion of the ground structure from the measured H/V curves. Two major approaches for forward calculation of NHVSRs in a layered medium are compared in this work. The first one was developed by Arai and Tokimatsu (2004) and recently improved by Albarello and Lunedei (2011). It consists of a description of the wavefield as generated by Far Surface point Forces (FSF method). The second one is based on the work of Sánchez-Sesma et al. (2011) who consider ambient noise as a Diffuse WaveField (DWF method), taking advantage of the proportionality between its Fourier-transformed autocorrelation (power spectrum) and the imaginary part of the Green function when source and receiver are the same. In both methods, the NHVSR is written as (PH/PV)1/2, where PH and PV are the horizontal and vertical power spectra. In the FSF method these quantities are given by PV∝⊙m(1+1/2χm2α2)(ARm/kRm)2 PH∝⊙m{(1+1/2χm2α2)(ARm/kRm)2χm2+1/2α2(ALm/kLm)2} where kRm, χm and ARm are wavenumber, ellipticity and medium response of the m-th Rayleigh wave mode; kLm and ALm correspond to the m-th Love wave mode and α is the horizontal-to-vertical load ratio of the ambient noise sources. Some common factors are omitted in the expressions of PV and PH. On the other hand, the DWF method deals with the full wavefield including both surface and body waves. In order to make the comparison easier, and taking into account that surface waves are often the dominant components in wide spectral ranges, body wave contributions are neglected here. In this case, the PH and PV power spectra for the DWF method are reduced to the simple expressions: PV = 1/2 ⊙m ARm PH = 1/2 ⊙m (ARm χm2 + ALm) Thus, the main difference between these methods is the way in which the amount of energy injected in each surface wave mode is established: either following the energy equipartition principle (DWF method) or controlled by surface point loads with angle tan-1 α (FSF method). These methods have been numerically compared for a simple structure consisting of a plane layer overlaying a halfspace. S-wave velocity contrast was varied between 2 and 6, and Poisson ratios of the layer from 0.25 to 0.45 (using 0.25 for the halfspace). We set α=1 for the FSF method. Although both methods provide NHVSRs of similar shape and very close peak frequencies, peaks obtained from DWF are significantly smoother. Both ratios become constant as frequency increases, but their high frequency limits differ too. References Albarello, D. & E. Lunedei (2011). Near Surface Geophysics 9, In press. Arai, H. & K. Tokimatsu (2004). Bull. Seismol. Soc. Am. 94, 53-63. Sánchez-Sesma, F. J., M. Rodríguez, U. Iturrarán-Viveros, F. Luzón, M. Campillo, L. Margerin, A. García-Jerez, M. Suarez, M. A. Santoyo & A. Rodríguez-Castellanos (2011). Geophys. J. Int. 186, 221-225.

  3. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Derivations and Verification of Plans. Volume 1

    NASA Technical Reports Server (NTRS)

    Johnson, Kenneth L.; White, K, Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques. This recommended procedure would be used as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. This document contains the outcome of the assessment.

  4. The Choice of the Filtering Method in Microarrays Affects the Inference Regarding Dosage Compensation of the Active X-Chromosome

    PubMed Central

    Zeller, Tanja; Wild, Philipp S.; Truong, Vinh; Trégouët, David-Alexandre; Munzel, Thomas; Ziegler, Andreas; Cambien, François; Blankenberg, Stefan; Tiret, Laurence

    2011-01-01

    Background The hypothesis of dosage compensation of genes of the X chromosome, supported by previous microarray studies, was recently challenged by RNA-sequencing data. It was suggested that microarray studies were biased toward an over-estimation of X-linked expression levels as a consequence of the filtering of genes below the detection threshold of microarrays. Methodology/Principal Findings To investigate this hypothesis, we used microarray expression data from circulating monocytes in 1,467 individuals. In total, 25,349 and 1,156 probes were unambiguously assigned to autosomes and the X chromosome, respectively. Globally, there was a clear shift of X-linked expressions toward lower levels than autosomes. We compared the ratio of expression levels of X-linked to autosomal transcripts (X∶AA) using two different filtering methods: 1. gene expressions were filtered out using a detection threshold irrespective of gene chromosomal location (the standard method in microarrays); 2. equal proportions of genes were filtered out separately on the X and on autosomes. For a wide range of filtering proportions, the X∶AA ratio estimated with the first method was not significantly different from 1, the value expected if dosage compensation was achieved, whereas it was significantly lower than 1 with the second method, leading to the rejection of the hypothesis of dosage compensation. We further showed in simulated data that the choice of the most appropriate method was dependent on biological assumptions regarding the proportion of actively expressed genes on the X chromosome comparative to the autosomes and the extent of dosage compensation. Conclusion/Significance This study shows that the method used for filtering out lowly expressed genes in microarrays may have a major impact according to the hypothesis investigated. The hypothesis of dosage compensation of X-linked genes cannot be firmly accepted or rejected using microarray-based data. PMID:21912656

  5. Full journal publication of abstracts presented at the Nordic Congress of General Practice in 2009 and 2011

    PubMed Central

    Waldorff, Frans Boch; Petersen, Kristine; Vinther, Siri; Sandholdt, Håkon; Siersma, Volkert; Andersen, John Sahl

    2017-01-01

    Objective To determine the overall publication rates for abstracts presented at two consecutive Nordic Congresses of General Practice and to evaluate determinants for these publication rates. Design Prospective study. Setting MEDLINE (PubMed) and Google Scholar were searched for relevant publications from 1 January 2009 up until 31 August 2014. Methods Abstracts accepted for oral or poster presentation were identified from the original congress booklets from the Nordic Congresses of General Practice in 2009 and 2011. Based on PubMed and Google Scholar searches, we subsequently identified full journal publications within a 36-month follow-up from both congresses. In cases of doubt, the first author was contacted directly. Main outcome measures Full journal publication within 36 months after the congress. Results A total of 200 abstracts were analyzed. Of these, 85 (42.5%) were identified with a full publication within 36 months after the congress. More abstracts from the 2011 congress were published compared to the 2009 congress odds ratio (OR) 1.97, 95% confidence interval (CI) (1.10; 3.50). Abstracts accepted for oral presentation were more often published OR 1.94, 95% CI (1.08; 3.50) than accepted poster abstracts. In the multivariate analysis, a university affiliation for both first and last author increased the probability for publication OR 4.23, 95% CI (1.71; 10.42), as well as more than two authors. An optimal number, based on the highest OR, seems to be 3–4 authors with OR 2.43, 95% CI (1.07; 5.54). Qualitative studies were published at the same frequency as quantitative studies OR 1.36, 95% CI (0.57; 3.24). Conclusion Less than half of the abstracts accepted for oral or poster presentation at two consecutive Nordic Congresses of General Practice were published as full text articles within 36 months. Key points Congress abstracts accepted for Nordic Congress of General Practice are not indexed in international search databases. Less than half of the abstracts accepted for oral or poster presentation at two consecutive Nordic Congresses of General Practice were published as full text articles within 36 months. Future congress committees could address this aspect in order to increase the visibility of and accessibility to research within the field of general practice. PMID:28277049

  6. Acceptability of contraception for men: a review.

    PubMed

    Glasier, Anna

    2010-11-01

    Methods of contraception for use by men include condoms, withdrawal and vasectomy. Prevalence of use of a method and continuation rates are indirect measures of acceptability. Worldwide, none of these "male methods" accounts for more than 7% of contraceptive use although uptake varies considerably between countries. Acceptability can be assessed directly by asking about intended (hypothetical) use and assessing satisfaction during/after use. Since they have been around for a very long time, there are very few data of this nature on condoms (as contraceptives rather than for prevention of infection), withdrawal or vasectomy. There are direct data on the acceptability of hormonal methods for men but from relatively small clinical trials which undoubtedly do not represent the real world. Surveys undertaken among the male general public demonstrate that, whatever the setting, at least 25% of men - and in most countries substantially more - would consider using hormonal contraception. Although probably an overestimate of the number of potential users when such a method becomes available, it would appear that hormonal contraceptives for men may have an important place on the contraceptive menu. Despite commonly expressed views to the contrary, most women would trust their male partner to use a hormonal method. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. Comparison of accelerated 3-D spiral chemical shift imaging and single-voxel spectroscopy at 3T in the pediatric age group.

    PubMed

    Yazbek, Sandrine; Prabhu, Sanjay P; Connaughton, Pauline; Grant, Patricia E; Gagoski, Borjan

    2015-08-01

    Single-voxel spectroscopy (SVS) is usually used in the pediatric population when a short acquisition time is crucial. To overcome the long acquisition time of 3-D phase-encoded chemical shift imaging (CSI) and lack of spatial coverage of single-voxel spectroscopy, efficient encoding schemes using spiral k-space trajectories have been successfully deployed, enabling acquisition of volumetric CSI in <5 min. We assessed feasibility of using 3-D spiral CSI sequence routinely in pediatric clinical settings by comparing its reconstructed spectra against SVS spectra. Volumetric spiral CSI obtained spectra from 2-cc isotropic voxels over a 16×16×10-cm region. SVS acquisition encoded a 3.4-cc (1.5-mm) isotropic voxel. Acquisition time was 3 min for every technique. Data were gathered prospectively from 11 random pediatric patients. Spectra from left basal ganglia were obtained using both techniques and were processed with post-processing software. The following metabolite ratios were calculated: N-acetylaspartate/creatine (NAA/Cr), choline/creatine (Cho/Cr), lactate/creatine (Lac/Cr) and N-acetylapartate/choline (NAA/Cho). We collected data on 11 children ages 4 days to 10 years. In 10/11 cases, spectral quality of both methods was acceptable. Considering 10/11 cases, we found a statistically significant difference between SVS and 3-D spiral CSI for all three ratios. However, this difference was fixed and was probably caused by a fixed bias. This means that 3-D spiral CSI can be used instead of SVS by removing the mean difference between the methods for each ratio. Accelerated 3-D CSI is feasible in pediatric patients and can potentially substitute for SVS.

  8. Optical and thermal simulation for wide acceptance angle CPV module

    NASA Astrophysics Data System (ADS)

    Ahmad, Nawwar; Ota, Yasuyuki; Araki, Kenji; Lee, Kan-Hua; Yamaguchi, Masafumi; Nishioka, Kensuke

    2017-09-01

    Concentrator photovoltaic (CPV) technology has the potential to decrease the cost of systems in the near future by using less expensive optical elements in the system which replace the receiving surface aperture and concentrate the sunlight onto small solar cells. One of the main concerns of CPV is the need for high precision tracking system and the relation to the acceptance angle. In this paper, we proposed a CPV module with concentration ratio larger than 100 times and wide acceptance angle. An optical simulation for the module with S-TIM2 glass as a lens material was conducted to estimate the optical performance of the module. Thermal and electrical simulation was also conducted using COMSOL Multiphysics and SPICE respectively to evaluate the working temperature and electrical characteristics of the multijunction solar cell under concentration conditions.

  9. Utility of gram stain in evaluation of sputa from patients with cystic fibrosis.

    PubMed Central

    Sadeghi, E; Matlow, A; MacLusky, I; Karmali, M A

    1994-01-01

    The utility of sputum Gram stain in assessing salivary contamination and in predicting the presence of pathogens on the basis of morphology was investigated in 287 respiratory specimens from patients with cystic fibrosis. Where acceptability for culture was defined as a leukocyte/squamous epithelial cell ratio of > 5, 76.6% (220 of 287) of respiratory specimens received in the laboratory were considered acceptable. Unacceptable specimens were more common in younger patients. The positive predictive value of the Gram stain for growth from acceptable sputum samples was 98% for Pseudomonas aeruginosa, 84.4% for Pseudomonas cepacia, 86.3% for Staphylococcus aureus, and 100% for Haemophilus influenzae. In cystic fibrosis patients, as has been reported for respiratory specimens in general, Gram stain of respiratory specimens in helpful for interpreting culture results. PMID:7510312

  10. The use of natural abundance stable isotopic ratios to indicate the presence of oxygen-containing chemical linkages between cellulose and lignin in plant cell walls.

    PubMed

    Zhou, Youping; Stuart-Williams, Hilary; Farquhar, Graham D; Hocart, Charles H

    2010-06-01

    Qualitative and quantitative understanding of the chemical linkages between the three major biochemical components (cellulose, hemicellulose and lignin) of plant cell walls is crucial to the understanding of cell wall structure. Although there is convincing evidence for chemical bonds between hemicellulose and lignin and the absence of chemical bonds between hemicellulose and cellulose, there is no conclusive evidence for the presence of covalent bonds between cellulose and lignin. This is caused by the lack of selectivity of current GC/MS-, NMR- and IR-based methods for lignin characterisation as none of these techniques directly targets the possible ester and ether linkages between lignin and cellulose. We modified the widely-accepted "standard" three-step extraction method for isolating cellulose from plants by changing the order of the steps for hemicellulose and lignin removal (solubilisation with concentrated NaOH and oxidation with acetic acid-containing NaClO(2), respectively) so that cellulose and lignin could be isolated with the possible chemical bonds between them intact. These linkages were then cleaved with NaClO(2) reagent in aqueous media of contrasting (18)O/(16)O ratios. We produced cellulose with higher purity (a lower level of residual hemicellulose and no detectable lignin) than that produced by the "standard" method. Oxidative artefacts may potentially be introduced at the lignin removal stage; but testing showed this to be minimal. Cellulose samples isolated from processing plant-derived cellulose-lignin mixtures in media of contrasting (18)O/(16)O ratios were compared to provide the first quantitative evidence for the presence of oxygen-containing ester and ether bonds between cellulose and lignin in Zea mays leaves. However, no conclusive evidence for the presence or lack of similar bonds in Araucaria cunninghamii wood was obtained. Copyright 2010 Elsevier Ltd. All rights reserved.

  11. Comparative bioavailability and pharmacokinetics of two oral formulations of flurbiprofen: a single-dose, randomized, open-label, two-period, crossover study in Pakistani subjects.

    PubMed

    Qayyum, Aisha; Najmi, Muzammil Hasan; Abbas, Mateen

    2013-11-01

    Comparative bioavailability studies are conducted to establish the bioequivalence of generic formulation with that of branded reference formulation, providing confidence to clinicians to use these products interchangeably. This study was carried out to compare a locally manufactured formulation of flurbiprofen with that of a branded product. Twenty two healthy male adults received a single dose of flurbiprofen (100mg) either generic or branded product according to randomization scheme on each of 2 periods. Blood samples were collected and plasma flurbiprofen concentration was determined by a validated HPLC method. Pharmacokinetic parameters like AUC(0-t), AUC(0-oo), Cmax, Tmax, t½, Vd and clearance were determined. The 90% CI for the ratio of geometric means of test to reference product's pharmacokinetic variables was calculated. Pharmacokinetic parameters for two formulations were comparable. Ratio of means of AUC(0-24), AUC(0-oo) and Cmax for test to reference products and 90% CI for these ratios were within the acceptable range. The p-values calculated by TOST were much less than the specified value (p-0.05). ANOVA gave p-values which were more than the specified value (p-0.05) for sequence, subject, period and formulation. Test formulation of flurbiprofen (tablet Flurso) was found to meet the criteria for bioequivalence to branded product (tablet Ansaid) based on pharmacokinetic parameters.

  12. College Student Invulnerability Beliefs and HIV Vaccine Acceptability

    ERIC Educational Resources Information Center

    Ravert, Russell D.; Zimet, Gregory D.

    2009-01-01

    Objective: To examine behavioral history, beliefs, and vaccine characteristics as predictors of HIV vaccine acceptability. Methods: Two hundred forty-five US under graduates were surveyed regarding their sexual history, risk beliefs, and likelihood of accepting hypothetical HIV vaccines. Results: Multivariate regression analysis indicated that…

  13. A comparison of freeze-drying and oven-drying preparation methods for bulk and compound-specific carbon stable isotope analyses: examples using the benthic macroinvertebrates Stenopsyche marmorata and Epeorus latifolium.

    PubMed

    Akamatsu, Fumikazu; Suzuki, Yaeko; Kato, Yoshikazu; Yoshimizu, Chikage; Tayasu, Ichiro

    2016-01-15

    Carbon stable isotope analysis of bulk samples and fatty acids is an established method for tracing carbon flow pathways and reconstructing trophic interactions, but there is no consensus on which sample drying method should be used for sample preparation. The aim of this study was to determine if freeze-drying and oven-drying treatments used to prepare samples of the benthic macroinvertebrates Stenopsyche marmorata and Epeorus latifolium for bulk and fatty-acid-specific carbon stable isotope analysis yield different isotopic ratio values. Five individuals each from two species were split in half; one half was freeze-dried and the other half was oven-dried. The samples were ground and the δ(13)C values of the bulk samples and eight fatty acids were measured following combustion using an isotope ratio mass spectrometer coupled to an elemental analyzer or gas chromatography system. The mean difference in the bulk and fatty acid δ(13)C values between freeze-dried and oven-dried samples was small (≤0.1‰ in both cases), although relatively large variations were observed in individual fatty-acid-specific δ(13)C values (maximum of ≤0.9 ‰). There were no significant differences in either bulk sample or fatty-acid-specific δ(13)C values between freeze-dried or oven-dried samples of the same species. Freeze-drying and oven-drying are equally acceptable methods for preparing freshly caught S. marmorata and E. latifolium samples for bulk and fatty-acid-specific carbon stable isotope analyses. Copyright © 2015 John Wiley & Sons, Ltd.

  14. Effectiveness of Home-based Management of Newborn Infections by Community Health Workers in Rural Bangladesh

    PubMed Central

    Baqui, Abdullah H.; Arifeen, Shams E.; Williams, Emma K.; Ahmed, Saifuddin; Mannan, Ishtiaq; Rahman, Syed M.; Begum, Nazma; Seraji, Habibur R.; Winch, Peter J.; Santosham, Mathuram; Black, Robert E.; Darmstadt, Gary L.

    2010-01-01

    Background Infections account for about half of neonatal deaths in low-resource settings. Limited evidence supports home-based treatment of newborn infections by community health workers (CHW). Methods In one study arm of a cluster randomized controlled trial, CHWs assessed neonates at home using a 20-sign clinical algorithm and classified sick neonates as having very severe disease or possible very severe disease. Over a two-year period, 10 585 live births were recorded in the study area. CHWs assessed 8474 (80%) of the neonates within the first week of life and referred neonates with signs of severe disease. If referral failed but parents consented to home treatment, CHWs treated neonates with very severe disease or possible very severe disease with multiple signs, using injectable antibiotics. Results For very severe disease, referral compliance was 34% (162/478 cases), and home treatment acceptance was 43% (204/478 cases). The case fatality rate was 4.4% (9/204) for CHW treatment, 14.2% (23/162) for treatment by qualified medical providers, and 28.5% (32/112) for those who received no treatment or who were treated by other unqualified providers. After controlling for differences in background characteristics and illness signs among treatment groups, newborns treated by CHWs had a hazard ratio of 0.22 (95% confidence interval 0.07–0.71) for death during the neonatal period and those treated by qualified providers had a hazard ratio of 0.61 (95% confidence interval of 0.37–0.99), compared with newborns who received no treatment or were treated by untrained providers. Significantly increased hazards ratios of death were observed for neonates with convulsions (HR 6.54; 95% CI 3.98–10.76), chest in-drawing (HR 2.38, 95% CI 1.29–4.39), temperature < 35.3°C (HR 3.47, 95% CI 1.30–9.24), unconsciousness (HR 7.92, 95% CI 3.13–20.04). Conclusions Home treatment of very severe disease in neonates by CHWs was effective and acceptable in a low-resource setting in Bangladesh. PMID:19289979

  15. Menses cup evaluation study.

    PubMed

    Cheng, M; Kung, R; Hannah, M; Wilansky, D; Shime, J

    1995-09-01

    To determine whether the menses cup is well tolerated by menstruating women. Prospective descriptive clinical study. Normal human volunteers in an academic research environment. Fifty-one menstruating women recruited between June to December 1991. Each participant was provided with two menses cups and an instruction sheet. Baseline information, including age, occupation, martial status, parity, description of menstrual flow, and current method used to cope with menstrual flow was collected. Subjects were asked to describe their experience with the cup at 1-, 2-, 6-, and 12-month intervals. The proportion of women who found the cup acceptable. The cup was used by 51 subjects for a total of 159 cycles. Overall, 23 women (45%) found the cup an acceptable method for coping with menses. Among 29 (57%) women who used the cup for two or more cycles, 62% found it acceptable. The menses cup may be an acceptable method for some women for coping with menstrual flow.

  16. 76 FR 60364 - Net Worth and Equity Ratio

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-29

    ... to ``follow the new Financial Accounting Standards Board (FASB) rule while still allowing the capital... accepted accounting principles and as further defined in Sec. 702.2(f) of this chapter. * * * * * [[Page... also proposed technical changes to the term ``net worth'' to ensure consistency and accurate accounting...

  17. Determinants of sensory acceptability in grapefruit

    USDA-ARS?s Scientific Manuscript database

    Early research reported that flavor in grapefruit was associated with the ratio of soluble solids (SSC) to titratable acidity (TA) and the juice content of the fruit. This led to the development of maturity standards based upon these parameters to define when grapefruit could be legally harvested i...

  18. Strengthening of bridge columns subjected to an impact lateral load caused by vehicle collision : phase I final report.

    DOT National Transportation Integrated Search

    2011-08-01

    "Fiber reinforced polymer (FRP) materials have gained wide acceptance for repair and retrofit of existing infrastructures or to design new infrastructures due to their desirable properties (high strength to weight ratio, light weight and consequent e...

  19. Evaluation of freeway motorist assist program : final report, September 30, 2009.

    DOT National Transportation Integrated Search

    2010-02-01

    This evaluation of the Motorist Assist (MA) program in St. Louis estimated that MA has an annual benefit-cost ratio (B/C) of 38.25:1 using 2009 dollars. This estimate was based on nationally accepted AASHTO methodology and was based on 1082 secondary...

  20. Quantification of uncertainty in machining operations for on-machine acceptance.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Claudet, Andre A.; Tran, Hy D.; Su, Jiann-Chemg

    2008-09-01

    Manufactured parts are designed with acceptance tolerances, i.e. deviations from ideal design conditions, due to unavoidable errors in the manufacturing process. It is necessary to measure and evaluate the manufactured part, compared to the nominal design, to determine whether the part meets design specifications. The scope of this research project is dimensional acceptance of machined parts; specifically, parts machined using numerically controlled (NC, or also CNC for Computer Numerically Controlled) machines. In the design/build/accept cycle, the designer will specify both a nominal value, and an acceptable tolerance. As part of the typical design/build/accept business practice, it is required to verifymore » that the part did meet acceptable values prior to acceptance. Manufacturing cost must include not only raw materials and added labor, but also the cost of ensuring conformance to specifications. Ensuring conformance is a substantial portion of the cost of manufacturing. In this project, the costs of measurements were approximately 50% of the cost of the machined part. In production, cost of measurement would be smaller, but still a substantial proportion of manufacturing cost. The results of this research project will point to a science-based approach to reducing the cost of ensuring conformance to specifications. The approach that we take is to determine, a priori, how well a CNC machine can manufacture a particular geometry from stock. Based on the knowledge of the manufacturing process, we are then able to decide features which need further measurements from features which can be accepted 'as is' from the CNC. By calibration of the machine tool, and establishing a machining accuracy ratio, we can validate the ability of CNC to fabricate to a particular level of tolerance. This will eliminate the costs of checking for conformance for relatively large tolerances.« less

  1. Factors associated with acceptance of provider-initiated HIV testing and counseling among pregnant women in Ethiopia.

    PubMed

    Gebremedhin, Ketema Bizuwork; Tian, Bingjie; Tang, Chulei; Zhang, Xiaoxia; Yisma, Engida; Wang, Honghong

    2018-01-01

    The global human immunodeficiency virus (HIV) epidemic disproportionately affects sub-Saharan African countries, including Ethiopia. Provider-initiated HIV testing and counseling (PITC) is a tool to identify HIV-positive pregnant women and an effective treatment and prevention strategy. However, its success depends upon the willingness of pregnant women to accept HIV testing. To describe the level of acceptance of PITC and associated factors among pregnant women attending 8 antenatal care clinics in Adama, Ethiopia. Trained nursing students and employees from an HIV clinic conducted face-to-face structured interviews in private offices at the clinics from August to September, 2016. Among the 441 respondents, 309 (70.1%) accepted PITC. Women with more antenatal care visits (odds ratio [OR] =2.59, 95% CI: 1.01-6.63), reported better quality of the PITC service (OR =1.91, 95% CI: 1.19-3.08), and higher level of knowledge on mother-to-child transmission (OR =1.82, 95% CI: 1.03-3.20), were more likely to accept PITC, while women who were older in age (OR =0.37, 95% CI: 0.19-0.74) and perceived negative attitudes from their partners toward HIV-positive results (OR =0.31, 95% CI: 0.10-0.94) were less likely to accept the PITC service. About one-third of pregnant women are not willing to accept PITC. When designing intervention program to improve the acceptance of PITC, we should take into consideration the personal factors, HIV-related knowledge, and attitude of women as well as institutional factors.

  2. Impact of evergreening on patients and health insurance: a meta analysis and reimbursement cost analysis of citalopram/escitalopram antidepressants

    PubMed Central

    2012-01-01

    Background "Evergreening" refers to the numerous strategies whereby owners of pharmaceutical products use patent laws and minor drug modifications to extend their monopoly privileges on the drug. We aimed to evaluate the impact of evergreening through the case study of the antidepressant citalopram and its chiral switch form escitalopram by evaluating treatment efficacy and acceptability for patients, as well as health insurance costs for society. Methods To assess efficacy and acceptability, we performed meta-analyses for efficacy and acceptability. We compared direct evidence (meta-analysis of results of head-to-head trials) and indirect evidence (adjusted indirect comparison of results of placebo-controlled trials). To assess health insurance costs, we analyzed individual reimbursement data from a representative sample of the French National Health Insurance Inter-regime Information System (SNIIR-AM) from 2003 to 2010, which allowed for projecting these results to the whole SNIIR-AM population (53 million people). Results In the meta-analysis of seven head-to-head trials (2,174 patients), efficacy was significantly better for escitalopram than citalopram (combined odds ratio (OR) 1.60 (95% confidence interval 1.05 to 2.46)). However, for the adjusted indirect comparison of 10 citalopram and 12 escitalopram placebo-controlled trials, 2,984 and 3,777 patients respectively, efficacy was similar for the two drug forms (combined indirect OR 1.03 (0.82 to 1.30)). Because of the discrepancy, we could not combine direct and indirect data (test of inconsistency, P = 0.07). A similar discrepancy was found for treatment acceptability. The overall reimbursement cost burden for the citalopram, escitalopram and its generic forms was 120.6 million Euros in 2010, with 96.8 million Euros for escitalopram. Conclusions The clinical benefit of escitalopram versus citalopram remains uncertain. In our case of evergreening, escitalopram represented a substantially high proportion of the overall reimbursement cost burden as compared with citalopram and the generic forms. PMID:23167972

  3. Improved harvesting systems for wet sites

    Treesearch

    Bryce J. Stokes; Alvin Schilling

    1997-01-01

    Environmentally acceptable and economical forest operations are needed for sustainable management of forest resources. Improved methods for harvesting and transporting timber are especially needed for wet sites. As the demand for hardwood lumber continues to increase, improved and alternative methods are needed to ensure acceptance of timber harvesting for the wet site...

  4. Gas alternatives to carbon dioxide for euthanasia: A piglet perspective

    USDA-ARS?s Scientific Manuscript database

    The search for alternative methods to euthanize piglets is critical to address the public’s concern that current methods are not acceptable. Scientific evidence support that blunt force trauma is humane when carried out correctly, but most people find it visually difficult to accept. The use of carb...

  5. 7 CFR 1783.8 - What are the acceptable methods for submitting applications?

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 12 2013-01-01 2013-01-01 false What are the acceptable methods for submitting applications? 1783.8 Section 1783.8 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE (CONTINUED) REVOLVING FUNDS FOR FINANCING WATER AND WASTEWATER...

  6. 7 CFR 1783.8 - What are the acceptable methods for submitting applications?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 12 2012-01-01 2012-01-01 false What are the acceptable methods for submitting applications? 1783.8 Section 1783.8 Agriculture Regulations of the Department of Agriculture (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE (CONTINUED) REVOLVING FUNDS FOR FINANCING WATER AND WASTEWATER...

  7. [Minimum Standards for the Spatial Accessibility of Primary Care: A Systematic Review].

    PubMed

    Voigtländer, S; Deiters, T

    2015-12-01

    Regional disparities of access to primary care are substantial in Germany, especially in terms of spatial accessibility. However, there is no legally or generally binding minimum standard for the spatial accessibility effort that is still acceptable. Our objective is to analyse existing minimum standards, the methods used as well as their empirical basis. A systematic literature review was undertaken of publications regarding minimum standards for the spatial accessibility of primary care based on a title word and keyword search using PubMed, SSCI/Web of Science, EMBASE and Cochrane Library. 8 minimum standards from the USA, Germany and Austria could be identified. All of them specify the acceptable spatial accessibility effort in terms of travel time; almost half include also distance(s). The travel time maximum, which is acceptable, is 30 min and it tends to be lower in urban areas. Primary care is, according to the identified minimum standards, part of the local area (Nahbereich) of so-called central places (Zentrale Orte) providing basic goods and services. The consideration of means of transport, e. g. public transport, is heterogeneous. The standards are based on empirical studies, consultation with service providers, practical experiences, and regional planning/central place theory as well as on legal or political regulations. The identified minimum standards provide important insights into the effort that is still acceptable regarding spatial accessibility, i. e. travel time, distance and means of transport. It seems reasonable to complement the current planning system for outpatient care, which is based on provider-to-population ratios, by a gravity-model method to identify places as well as populations with insufficient spatial accessibility. Due to a lack of a common minimum standard we propose - subject to further discussion - to begin with a threshold based on the spatial accessibility limit of the local area, i. e. 30 min to the next primary care provider for at least 90% of the regional population. The exceeding of the threshold would necessitate a discussion of a health care deficit and in line with this a potential need for intervention, e. g. in terms of alternative forms of health care provision. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Fitness level and body composition indices: cross-sectional study among Malaysian adolescent.

    PubMed

    Hanifah, Redzal Abu; Majid, Hazreen Abdul; Jalaludin, Muhammad Yazid; Al-Sadat, Nabilla; Murray, Liam J; Cantwell, Marie; Su, Tin Tin; Nahar, Azmi Mohamed

    2014-01-01

    The importance of fitness level on the well-being of children and adolescent has long been recognised. The aim of this study was to investigate the fitness level of school-going Malaysian adolescent, and its association with body composition indices. 1071 healthy secondary school students participated in the fitness assessment for the Malaysian Health and Adolescents Longitudinal Research Team (MyHEART) study. Body composition indices such as body mass index for age, waist circumference and waist height ratio were measured. Fitness level was assessed with Modified Harvard Step Test. Physical Fitness Score was calculated using total time of step test exercise and resting heart rates. Fitness levels were divided into 3 categories - unacceptable, marginally acceptable, and acceptable. Partial correlation analysis was used to determine the association between fitness score and body composition, by controlling age, gender, locality, ethnicity, smoking status and sexual maturation. Multiple regression analysis was conducted to determine which body composition was the strongest predictor for fitness. 43.3% of the participants were categorised into the unacceptable fitness group, 47.1% were considered marginally acceptable, and 9.6% were acceptable. There was a significant moderate inverse association (p < 0.001) between body composition with fitness score (r = -0.360, -0.413 and -0.403 for body mass index for age, waist circumference and waist height ratio, respectively). Waist circumference was the strongest and significant predictor for fitness (ß = -0.318, p = 0.002). Only 9.6% of the students were fit. There was also an inverse association between body composition and fitness score among apparently healthy adolescents, with waist circumference indicated as the strongest predictor. The low fitness level among the Malaysian adolescent should necessitate the value of healthy lifestyle starting at a young age.

  9. Detecting Initiation or Risk for Initiation of Substance Use before High School during Pediatric Well-Child Check-Ups

    PubMed Central

    Ridenour, Ty A.; Willis, David; Bogen, Debra L.; Novak, Scott; Scherer, Jennifer; Reynolds, Maureen D.; Zhai, Zu Wei; Tarter, Ralph E.

    2015-01-01

    Background Youth substance use (SU) is prevalent and costly, affecting mental and physical health. American Academy of Pediatrics and Affordable Care Act call for SU screening and prevention. The Youth Risk Index© (YRI) was tested as a screening tool for having initiated and propensity to initiate SU before high school (which forecasts SU disorder). YRI was hypothesized to have good to excellent psychometrics, feasibility and stakeholder acceptability for use during well-child check-ups. Design A high-risk longitudinal design with two cross-sectional replication samples, ages 9–13 was used. Analyses included receiver operating characteristics and regression analyses. Participants A one-year longitudinal sample (N=640) was used for YRI derivation. Replication samples were a cross-sectional sample (N=345) and well-child check-up patients (N=105) for testing feasibility, validity and acceptability as a screening tool. Results YRI has excellent test-retest reliability and good sensitivity and specificity for concurrent and one-year-later SU (odds ratio=7.44 CI=4.3–13.0) and conduct problems (odds ratios=7.33 CI=3.9–13.7). Results were replicated in both cross-sectional samples. Well-child patients, parents and pediatric staff rated YRI screening as important, acceptable, and a needed service. Conclusions Identifying at-risk youth prior to age 13 could reap years of opportunity to intervene before onset of SU disorder. Most results pertained to YRI’s association with concurrent or recent past risky behaviors; further replication ought to specify its predictive validity, especially adolescent-onset risky behaviors. YRI well identifies youth at risk for SU and conduct problems prior to high school, is feasible and valid for screening during well-child check-ups, and is acceptable to stakeholders. PMID:25765481

  10. A Web-based Tool to Aid the Identification of Chemicals Potentially Posing a Health Risk through Percutaneous Exposure.

    PubMed

    Gorman Ng, Melanie; Milon, Antoine; Vernez, David; Lavoué, Jérôme

    2016-04-01

    Occupational hygiene practitioners typically assess the risk posed by occupational exposure by comparing exposure measurements to regulatory occupational exposure limits (OELs). In most jurisdictions, OELs are only available for exposure by the inhalation pathway. Skin notations are used to indicate substances for which dermal exposure may lead to health effects. However, these notations are either present or absent and provide no indication of acceptable levels of exposure. Furthermore, the methodology and framework for assigning skin notation differ widely across jurisdictions resulting in inconsistencies in the substances that carry notations. The UPERCUT tool was developed in response to these limitations. It helps occupational health stakeholders to assess the hazard associated with dermal exposure to chemicals. UPERCUT integrates dermal quantitative structure-activity relationships (QSARs) and toxicological data to provide users with a skin hazard index called the dermal hazard ratio (DHR) for the substance and scenario of interest. The DHR is the ratio between the estimated 'received' dose and the 'acceptable' dose. The 'received' dose is estimated using physico-chemical data and information on the exposure scenario provided by the user (body parts exposure and exposure duration), and the 'acceptable' dose is estimated using inhalation OELs and toxicological data. The uncertainty surrounding the DHR is estimated with Monte Carlo simulation. Additional information on the selected substances includes intrinsic skin permeation potential of the substance and the existence of skin notations. UPERCUT is the only available tool that estimates the absorbed dose and compares this to an acceptable dose. In the absence of dermal OELs it provides a systematic and simple approach for screening dermal exposure scenarios for 1686 substances. © The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  11. Real-Time Clinical Decision Support Decreases Inappropriate Plasma Transfusion.

    PubMed

    Shah, Neil; Baker, Steven A; Spain, David; Shieh, Lisa; Shepard, John; Hadhazy, Eric; Maggio, Paul; Goodnough, Lawrence T

    2017-08-01

    To curtail inappropriate plasma transfusions, we instituted clinical decision support as an alert upon order entry if the patient's recent international normalized ratio (INR) was 1.7 or less. The alert was suppressed for massive transfusion and within operative or apheresis settings. The plasma order was automatically removed upon alert acceptance while clinical exception reasons allowed for continued transfusion. Alert impact was studied comparing a 7-month control period with a 4-month intervention period. Monthly plasma utilization decreased 17.4%, from a mean ± SD of 3.40 ± 0.48 to 2.82 ± 0.6 plasma units per hundred patient days (95% confidence interval [CI] of difference, -0.1 to 1.3). Plasma transfused below an INR of 1.7 or less decreased from 47.6% to 41.6% (P = .0002; odds ratio, 0.78; 95% CI, 0.69-0.89). The alert recommendation was accepted 33% of the time while clinical exceptions were chosen in the remaining cases (active bleeding, 31%; other clinical indication, 33%; and apheresis, 2%). Alert acceptance rate varied significantly among different provider specialties. Clinical decision support can help curtail inappropriate plasma use but needs to be part of a comprehensive strategy including audit and feedback for comprehensive, long-term changes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  12. Estimation of effective brain connectivity with dual Kalman filter and EEG source localization methods.

    PubMed

    Rajabioun, Mehdi; Nasrabadi, Ali Motie; Shamsollahi, Mohammad Bagher

    2017-09-01

    Effective connectivity is one of the most important considerations in brain functional mapping via EEG. It demonstrates the effects of a particular active brain region on others. In this paper, a new method is proposed which is based on dual Kalman filter. In this method, firstly by using a brain active localization method (standardized low resolution brain electromagnetic tomography) and applying it to EEG signal, active regions are extracted, and appropriate time model (multivariate autoregressive model) is fitted to extracted brain active sources for evaluating the activity and time dependence between sources. Then, dual Kalman filter is used to estimate model parameters or effective connectivity between active regions. The advantage of this method is the estimation of different brain parts activity simultaneously with the calculation of effective connectivity between active regions. By combining dual Kalman filter with brain source localization methods, in addition to the connectivity estimation between parts, source activity is updated during the time. The proposed method performance has been evaluated firstly by applying it to simulated EEG signals with interacting connectivity simulation between active parts. Noisy simulated signals with different signal to noise ratios are used for evaluating method sensitivity to noise and comparing proposed method performance with other methods. Then the method is applied to real signals and the estimation error during a sweeping window is calculated. By comparing proposed method results in different simulation (simulated and real signals), proposed method gives acceptable results with least mean square error in noisy or real conditions.

  13. Σ0 production in proton nucleus collisions near threshold

    NASA Astrophysics Data System (ADS)

    Adamczewski-Musch, J.; Agakishiev, G.; Arnold, O.; Atomssa, E. T.; Behnke, C.; Berger-Chen, J. C.; Biernat, J.; Blanco, A.; Blume, C.; Böhmer, M.; Bordalo, P.; Chernenko, S.; Deveaux, C.; Dybczak, A.; Epple, E.; Fabbietti, L.; Fateev, O.; Fonte, P.; Franco, C.; Friese, J.; Fröhlich, I.; Galatyuk, T.; Garzón, J. A.; Gernhäuser, R.; Gill, K.; Golubeva, M.; Guber, F.; Gumberidze, M.; Harabasz, S.; Hennino, T.; Hlavac, S.; Höhne, C.; Holzmann, R.; Ierusalimov, A.; Ivashkin, A.; Jurkovic, M.; Kämpfer, B.; Karavicheva, T.; Kardan, B.; Koenig, I.; Koenig, W.; Kolb, B. W.; Korcyl, G.; Kornakov, G.; Kotte, R.; Krása, A.; Krebs, E.; Kuc, H.; Kugler, A.; Kunz, T.; Kurepin, A.; Kurilkin, A.; Kurilkin, P.; Ladygin, V.; Lalik, R.; Lapidus, K.; Lebedev, A.; Lopes, L.; Lorenz, M.; Mahmoud, T.; Maier, L.; Maurus, S.; Mangiarotti, A.; Markert, J.; Metag, V.; Michel, J.; Müntz, C.; Münzer, R.; Naumann, L.; Palka, M.; Parpottas, Y.; Pechenov, V.; Pechenova, O.; Petousis, V.; Pietraszko, J.; Przygoda, W.; Ramos, S.; Ramstein, B.; Rehnisch, L.; Reshetin, A.; Rost, A.; Rustamov, A.; Sadovsky, A.; Salabura, P.; Scheib, T.; Schmidt-Sommerfeld, K.; Schuldes, H.; Sellheim, P.; Siebenson, J.; Silva, L.; Sobolev, Yu. G.; Spataro, S.; Ströbele, H.; Stroth, J.; Strzempek, P.; Sturm, C.; Svoboda, O.; Tarantola, A.; Teilab, K.; Tlusty, P.; Traxler, M.; Tsertos, H.; Vasiliev, T.; Wagner, V.; Wendisch, C.; Wirth, J.; Wüstenfeld, J.; Zanevsky, Y.; Zumbruch, P.; Hades Collaboration

    2018-06-01

    The production of Σ0 baryons in the nuclear reaction p (3.5 GeV) + Nb (corresponding to √{sNN } = 3.18 GeV) is studied with the detector set-up HADES at GSI, Darmstadt. Σ0s were identified via the decay Σ0 → Λγ with subsequent decays Λ → pπ- in coincidence with a e+e- pair from either external (γ →e+e-) or internal (Dalitz decay γ* →e+e-) gamma conversions. The differential Σ0 cross section integrated over the detector acceptance, i.e. the rapidity interval 0.5 < y < 1.1, has been extracted as ΔσΣ0 = 2.3 ±(0.2) stat ±(-0.6+0.6)sys ±(0.2) norm mb, yielding the inclusive production cross section in full phase space σΣ0total = 5.8 ±(0.5) stat ± (-1.4+1.4)sys ±(0.6) norm ±(1.7) extrapol mb by averaging over different extrapolation methods. The Λall/Σ0 ratio within the HADES acceptance is equal to 2.3 ±(0.2) stat ± (-0.6+0.6)sys. The obtained rapidity and momentum distributions are compared to transport model calculations. The Σ0 yield agrees with the statistical model of particle production in nuclear reactions.

  14. Assessment of the environmental fate and effects of azilsartan, a selective antagonist of angiotensin II type 1.

    PubMed

    Weltman, R; Brands, C M J; Corral, E; Desmares-Koopmans, M J E; Migchielsen, M H J; Oudhoff, K A; de Roode, D F

    2012-06-01

    In this paper the results of a thorough evaluation of the environmental fate and effects of azilsartan are presented. Azilsartan medoxomil is administered as a pro-drug for the treatment of patients with essential hypertension. The pro-drug is converted by hydrolysis to the active pharmaceutical ingredient azilsartan. Laboratory tests to evaluate the environmental fate and effects of azilsartan medoxomil were conducted with azilsartan and performed in accordance with OECD test guidelines. The predicted environmental concentration (PEC) in surface water was estimated at 0.32 μg L(-1) (above the action limit of 0.01 μg L(-1)), triggering a Phase II assessment. Azilsartan is not readily biodegradable. Results of the water sediment study demonstrated significant shifting of azilsartan metabolites to sediment. Based on the equilibrium partitioning method, metabolites are unlikely to pose a risk to sediment-dwelling organisms. Ratios of the predicted environmental concentrations (PECs) to the predicted-no-effect concentrations (PNECs) did not exceed the relevant triggers, and the risk to aquatic, sewage treatment plant (STP), groundwater and sediment compartments was concluded acceptable. A terrestrial assessment was not triggered. Azilsartan poses an acceptable risk to the environment. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Assessing bioequivalence of generic modified-release antiepileptic drugs

    PubMed Central

    Chang, Yi-Ting; Davit, Barbara; Gidal, Barry E.; Krauss, Gregory L.

    2016-01-01

    Objectives: The purpose of this study was to determine how closely generic modified-release antiepileptic drugs (MR-AEDs) resemble reference (brand) formulations by comparing peak concentrations (Cmax), total absorption (area under the curve [AUC]), time to Cmax (Tmax), intersubject variability, and food effects between generic and reference products. Methods: We tabulated Cmax and AUC data from the bioequivalence (BE) studies used to support the approvals of generic Food and Drug Administration–approved MR-AEDs. We compared differences in 90% confidence intervals of the generic/reference AUC and Cmax geometric mean ratios, and intersubject variability, Tmax and delivery profiles and food effects. Results: Forty-two MR-AED formulations were studied in 3,175 healthy participants without epilepsy in 97 BE studies. BE ratios for AUC and Cmax were similar between most generic and reference products: AUC ratios varied by >15% in 11.4% of BE studies; Cmax varied by >15% in 25.8% of studies. Tmax was more variable, with >30% difference in 13 studies (usually delayed in the fed compared to fasting BE studies). Generic and reference MR products had similar intersubject variability. Immediate-release AEDs showed less intersubject variability in AUC than did MR-AEDs. Conclusions: Most generic and reference MR-AEDs have similar AUC and Cmax values. Ratios for some products, however, are near acceptance limits and Tmax values may vary. Food effects are common with MR-AED products. High variability in pharmacokinetic values for once-a-day MR-AEDs suggests their major advantage compared to immediate-release AED formulations may be the convenience of less frequent dosing to improve adherence. PMID:27016518

  16. Particle beam injector system and method

    DOEpatents

    Guethlein, Gary

    2013-06-18

    Methods and devices enable coupling of a charged particle beam to a radio frequency quadrupole accelerator. Coupling of the charged particle beam is accomplished, at least in-part, by relying on of sensitivity of the input phase space acceptance of the radio frequency quadrupole to the angle of the input charged particle beam. A first electric field across a beam deflector deflects the particle beam at an angle that is beyond the acceptance angle of the radio frequency quadrupole. By momentarily reversing or reducing the established electric field, a narrow portion of the charged particle beam is deflected at an angle within the acceptance angle of the radio frequency quadrupole. In another configuration, beam is directed at an angle within the acceptance angle of the radio frequency quadrupole by the first electric field and is deflected beyond the acceptance angle of the radio frequency quadrupole due to the second electric field.

  17. User Acceptance of Computerized Cognitive Behavioral Therapy for Depression: Systematic Review

    PubMed Central

    Rost, Theresia; Stein, Janine; Löbner, Margrit; Kersting, Anette; Luck-Sikorski, Claudia

    2017-01-01

    Background Computerized cognitive behavioral therapy (cCBT) has been proven to be effective in depression care. Moreover, cCBT packages are becoming increasingly popular. A central aspect concerning the take-up and success of any treatment is its user acceptance. Objective The aim of this study was to update and expand on earlier work on user acceptance of cCBT for depression. Methods This paper systematically reviewed quantitative and qualitative studies regarding the user acceptance of cCBT for depression. The initial search was conducted in January 2016 and involved the following databases: Web of Science, PubMed, the Cochrane Library, and PsycINFO. Studies were retained if they described the explicit examination of the user acceptance, experiences, or satisfaction related to a cCBT intervention, if they reported depression as a primary outcome, and if they were published in German or English from July 2007 onward. Results A total of 1736 studies were identified, of which 29 studies were eligible for review. User acceptance was operationalized and analyzed very heterogeneously. Eight studies reported a very high level of acceptance, 17 indicated a high level of acceptance, and one study showed a moderate level of acceptance. Two qualitative studies considered the positive and negative aspects concerning the user acceptance of cCBT. However, a substantial proportion of reviewed studies revealed several methodical shortcomings. Conclusions In general, people experience cCBT for depression as predominantly positive, which supports the potential role of these innovative treatments. However, methodological challenges do exist in terms of defining user acceptance, clear operationalization of concepts, and measurement. PMID:28903893

  18. Behavioral, Personality, and Communicative Predictors of Acceptance and Popularity in Early Adolescence

    ERIC Educational Resources Information Center

    Wolters, Nina; Knoors, Harry; Cillessen, Antonius H. N.; Verhoeven, Ludo

    2014-01-01

    This study examined the behavioral, personality, and communicative predictors of acceptance and popularity in 608 early adolescents. Data were collected with sociometric methods and ratings in 30 sixth-grade classrooms. Hierarchical regressions were run to predict acceptance and popularity from prosocial, antisocial, and withdrawn behavior,…

  19. 46 CFR 50.25-10 - Acceptance of piping components by specific letter or approved plan.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) MARINE ENGINEERING GENERAL PROVISIONS Acceptance of Material and Piping Components § 50.25-10 Acceptance... approved plan must do the following: (1) Submit an engineering type catalog or representative drawings of... specifications by comparing details of the materials' chemical composition, mechanical properties, method of...

  20. 46 CFR 50.25-10 - Acceptance of piping components by specific letter or approved plan.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) MARINE ENGINEERING GENERAL PROVISIONS Acceptance of Material and Piping Components § 50.25-10 Acceptance... approved plan must do the following: (1) Submit an engineering type catalog or representative drawings of... specifications by comparing details of the materials' chemical composition, mechanical properties, method of...

  1. 46 CFR 50.25-10 - Acceptance of piping components by specific letter or approved plan.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) MARINE ENGINEERING GENERAL PROVISIONS Acceptance of Material and Piping Components § 50.25-10 Acceptance... approved plan must do the following: (1) Submit an engineering type catalog or representative drawings of... specifications by comparing details of the materials' chemical composition, mechanical properties, method of...

  2. 46 CFR 50.25-10 - Acceptance of piping components by specific letter or approved plan.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) MARINE ENGINEERING GENERAL PROVISIONS Acceptance of Material and Piping Components § 50.25-10 Acceptance... approved plan must do the following: (1) Submit an engineering type catalog or representative drawings of... specifications by comparing details of the materials' chemical composition, mechanical properties, method of...

  3. 46 CFR 50.25-10 - Acceptance of piping components by specific letter or approved plan.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) MARINE ENGINEERING GENERAL PROVISIONS Acceptance of Material and Piping Components § 50.25-10 Acceptance... approved plan must do the following: (1) Submit an engineering type catalog or representative drawings of... specifications by comparing details of the materials' chemical composition, mechanical properties, method of...

  4. Attitude toward, acceptance of and knowledge about female sterilization as a method of contraception.

    PubMed

    Erlenwein, J; Kundu, S; Schippert, C; Soergel, P; Hillemanns, P; Staboulidou, I

    2015-02-01

    Surgical sterilization via tubal ligation or the disconnection of the tubes is a method of permanent contraception. The aim of this study was to evaluate the attitude, acceptance and knowledge of women about female sterilization as a method of contraception in terms of the social and cultural backgrounds of those women. Prospective study based on an anonymous questionnaire that analyzed background knowledge, attitude, influence factors and motivation regarding sterilization, as well as the reasons for declining. The questionnaire also attempted to evaluate the effects on the self-esteem of the women, as well as the impact of religious dogma and the related beliefs. One thousand, eight hundred questionnaires were distributed, and 1247 women completed the questionnaire—a response rate of 69.3%. There were mainly positive attitudes toward sterilization as a contraceptive method. Cultural background, including religion and faith; the mother's experiences and point of view; knowledge; family planning and the actual life situation have an influence on the attitudes toward and acceptance of sterilization as a contraceptive method and on the final choice of a contraceptive method. Cultural background and present life situation have a great impact on the attitude toward and acceptance of sterilization as a method of contraception, thus influencing the final choice of a contraceptive method. Detailed counselling about this topic is essential and should be improved. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. The Use of Acceptance to Promote Positive Change by Decreasing Shame and Guilt: A Practice Exemplar.

    PubMed

    Meltzer, Mary-Ellen

    2015-01-01

    The use of acceptance by mental health clinicians in the clinical setting is an effective method for providing a safe environment for clients to make positive changes. Acceptance means that mental health clinicians are non-judgmental and acknowledge the clients' situations as they are. When actively used by clinicians, acceptance decreases clients' anxiety and the intensity of their feelings of guilt and shame. Clients are then able to begin to accept themselves as they are. The purpose of this article is to discuss the ways in which mental health clinicians promote clients' acceptance of themselves using the tools of acceptance and commitment therapy and dialectical behavioral therapy.

  6. POWER AND SAMPLE SIZE CALCULATIONS FOR LINEAR HYPOTHESES ASSOCIATED WITH MIXTURES OF MANY COMPONENTS USING FIXED-RATIO RAY DESIGNS

    EPA Science Inventory

    Response surface methodology, often supported by factorial designs, is the classical experimental approach that is widely accepted for detecting and characterizing interactions among chemicals in a mixture. In an effort to reduce the experimental effort as the number of compound...

  7. The Acceptance of Universalism: The Importance of Selected Aspects of School Structure.

    ERIC Educational Resources Information Center

    Martin, Robert A.

    This report describes a study that investigated empirically the relationships between selected aspects of the organizational structure of elementary schools and the extent to which students endorsed the norm of universalism. Four aspects of structure were studied: degree of departmentalization, school enrollment, student-teacher ratio, and extent…

  8. Spectrum/Orbit-Utilization Program

    NASA Technical Reports Server (NTRS)

    Miller, Edward F.; Sawitz, Paul; Zusman, Fred

    1988-01-01

    Interferences among geostationary satellites determine allocations. Spectrum/Orbit Utilization Program (SOUP) is analytical computer program for determining mutual interferences among geostationary-satellite communication systems operating in given scenario. Major computed outputs are carrier-to-interference ratios at receivers at specified stations on Earth. Information enables determination of acceptability of planned communication systems. Written in FORTRAN.

  9. A Decision Support System for Energy Policy Analysis.

    DTIC Science & Technology

    1980-07-01

    new realities or hypothesized realities to the modeling system. Lack of a PDL would make the system inflexible and accessible only to a patient ... expert . Certainly, given the present ratio of costs of personnel to costs of computers, the alternative of presenting data in its raw form is acceptable

  10. SU-D-BRD-07: Evaluation of the Effectiveness of Statistical Process Control Methods to Detect Systematic Errors For Routine Electron Energy Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, S

    2015-06-15

    Purpose: To evaluate the ability of statistical process control methods to detect systematic errors when using a two dimensional (2D) detector array for routine electron beam energy verification. Methods: Electron beam energy constancy was measured using an aluminum wedge and a 2D diode array on four linear accelerators. Process control limits were established. Measurements were recorded in control charts and compared with both calculated process control limits and TG-142 recommended specification limits. The data was tested for normality, process capability and process acceptability. Additional measurements were recorded while systematic errors were intentionally introduced. Systematic errors included shifts in the alignmentmore » of the wedge, incorrect orientation of the wedge, and incorrect array calibration. Results: Control limits calculated for each beam were smaller than the recommended specification limits. Process capability and process acceptability ratios were greater than one in all cases. All data was normally distributed. Shifts in the alignment of the wedge were most apparent for low energies. The smallest shift (0.5 mm) was detectable using process control limits in some cases, while the largest shift (2 mm) was detectable using specification limits in only one case. The wedge orientation tested did not affect the measurements as this did not affect the thickness of aluminum over the detectors of interest. Array calibration dependence varied with energy and selected array calibration. 6 MeV was the least sensitive to array calibration selection while 16 MeV was the most sensitive. Conclusion: Statistical process control methods demonstrated that the data distribution was normally distributed, the process was capable of meeting specifications, and that the process was centered within the specification limits. Though not all systematic errors were distinguishable from random errors, process control limits increased the ability to detect systematic errors using routine measurement of electron beam energy constancy.« less

  11. Reliability of the method of levels for determining cutaneous temperature sensitivity

    NASA Astrophysics Data System (ADS)

    Jakovljević, Miroljub; Mekjavić, Igor B.

    2012-09-01

    Determination of the thermal thresholds is used clinically for evaluation of peripheral nervous system function. The aim of this study was to evaluate reliability of the method of levels performed with a new, low cost device for determining cutaneous temperature sensitivity. Nineteen male subjects were included in the study. Thermal thresholds were tested on the right side at the volar surface of mid-forearm, lateral surface of mid-upper arm and front area of mid-thigh. Thermal testing was carried out by the method of levels with an initial temperature step of 2°C. Variability of thermal thresholds was expressed by means of the ratio between the second and the first testing, coefficient of variation (CV), coefficient of repeatability (CR), intraclass correlation coefficient (ICC), mean difference between sessions (S1-S2diff), standard error of measurement (SEM) and minimally detectable change (MDC). There were no statistically significant changes between sessions for warm or cold thresholds, or between warm and cold thresholds. Within-subject CVs were acceptable. The CR estimates for warm thresholds ranged from 0.74°C to 1.06°C and from 0.67°C to 1.07°C for cold thresholds. The ICC values for intra-rater reliability ranged from 0.41 to 0.72 for warm thresholds and from 0.67 to 0.84 for cold thresholds. S1-S2diff ranged from -0.15°C to 0.07°C for warm thresholds, and from -0.08°C to 0.07°C for cold thresholds. SEM ranged from 0.26°C to 0.38°C for warm thresholds, and from 0.23°C to 0.38°C for cold thresholds. Estimated MDC values were between 0.60°C and 0.88°C for warm thresholds, and 0.53°C and 0.88°C for cold thresholds. The method of levels for determining cutaneous temperature sensitivity has acceptable reliability.

  12. A New Quantum Watermarking Based on Quantum Wavelet Transforms

    NASA Astrophysics Data System (ADS)

    Heidari, Shahrokh; Naseri, Mosayeb; Gheibi, Reza; Baghfalaki, Masoud; Rasoul Pourarian, Mohammad; Farouk, Ahmed

    2017-06-01

    Quantum watermarking is a technique to embed specific information, usually the owner’s identification, into quantum cover data such for copyright protection purposes. In this paper, a new scheme for quantum watermarking based on quantum wavelet transforms is proposed which includes scrambling, embedding and extracting procedures. The invisibility and robustness performances of the proposed watermarking method is confirmed by simulation technique. The invisibility of the scheme is examined by the peak-signal-to-noise ratio (PSNR) and the histogram calculation. Furthermore the robustness of the scheme is analyzed by the Bit Error Rate (BER) and the Correlation Two-Dimensional (Corr 2-D) calculation. The simulation results indicate that the proposed watermarking scheme indicate not only acceptable visual quality but also a good resistance against different types of attack. Supported by Kermanshah Branch, Islamic Azad University, Kermanshah, Iran

  13. Highly sensitive determination of diclofenac based on resin beads and a novel polyclonal antibody by using flow injection chemiluminescence competitive immunoassay

    NASA Astrophysics Data System (ADS)

    Shi, Jing; Xu, Mingxia; Tang, Qinghui; Zhao, Kang; Deng, Anping; Li, Jianguo

    2018-02-01

    A novel flow injection chemiluminescence immunoassay for simple, sensitive and low-cost detection of diclofenac was established based on specific binding of antigen and antibody. Carboxylic resin beads used as solid phase carrier materials provided good biocompatibility and large surface-to-volume ratio for modifying more coating antigen. There was a competitive process between the diclofenac in solution and the immobilized coating antigen to react with the limited binding sites of the polyclonal antibody to form the immunocomplex. The second antibody labelled with horseradish peroxidase was introduced into the immunosensor and trapped by captured polyclonal antibody against diclofenac, which could effectively amplify chemiluminescence signals of luminol-PIP-H2O2. Under optimal conditions, the diclofenac could be detected quantitatively. The chemiluminescence intensity decreased linearly with the logarithm of the diclofenac concentration in the range of 0.1-100 ng mL- 1 with a detection limit of 0.05 ng mL- 1 at a signal-to-noise ratio of 3. The immunosensor exhibited high sensitivity, specificity and acceptable stability. This easy-operated and cost-effective analytical method could be valuable for the diclofenac determination in real water samples.

  14. Oxidative degradation stability and hydrogen sulfide removal performance of dual-ligand iron chelate of Fe-EDTA/CA.

    PubMed

    Miao, Xinmei; Ma, Yiwen; Chen, Zezhi; Gong, Huijuan

    2017-09-05

    Catalytic oxidation desulfurization using chelated iron catalyst is an effective method to remove H 2 S from various gas streams including biogas. However, the ligand of ethylenediaminetetraacetic acid (EDTA), which is usually adopted to prepare chelated iron catalyst, is liable to be oxidative degraded, and leads to the loss of desulfurization performance. In order to improve the degradation stability of the iron chelate, a series of iron chelates composed of two ligands including citric acid (CA) and EDTA were prepared and the oxidative degradation stability as well as desulfurization performance of these chelated iron catalysts were studied. Results show that the iron chelate of Fe-CA is more stable than Fe-EDTA, while for the desulfurization performance, the situation is converse. For the dual-ligand iron chelates of Fe-EDTA/CA, with the increase of mol ratio of CA to EDTA in the iron chelate solution, the oxidative degradation stability increased while the desulfurization performance decreased. The results of this work showed that Fe-EDTA/CA with a mol ratio of CA:EDTA = 1:1 presents a relative high oxidative degradation stability and an acceptable desulfurization performance with over 90% of H 2 S removal efficiency.

  15. Analysis of InsureKidsNow.gov dental providers in New York State.

    PubMed

    Chinn, Courtney H; Rossy, Stephanie; Best, Elizabeth

    2013-01-01

    Study purposes were to: (1) validate information of New York State (NYS) pediatric dental Medicaid/CHIP providers registered on InsureKidsNow.gov (IKN); and (2) compare dental access to available IKN pediatric dental Medicaid provider locations by NYS region and population density of young children in poverty Methods: Information on 4,634 dental provider locations was obtained by collapsing 21,921 listings; 160 locations were randomly telephoned to verify consistency and provision of pediatric restorative treatment. Dental provider locations to poor child population ratios were compared. Over 90 percent of locations were in less than a third of NYS counties. New York City/Long Island locations had 5.68 higher odds of accepting new pediatric patients compared to locations in the rest of NYS. Of phone numbers called, 22 percent were invalid. Nearly 40 percent of valid calls were inconsistent with IKN. Over 90 percent of counties had at least one IKN dentist. The median child-in-poverty to provider ratio was 85:1. Improved oversight of InsureKidsNow.gov is required to ensure validity and usefulness. Research on the quantity and type of child Medicaid/CHIP dental procedures in private practice is needed to accurately assess dental access.

  16. Vasectomy and vasectomy reversal the Thai way.

    PubMed

    Gojaseni, P

    1982-12-01

    In 1972 the ratio of female sterilization acceptors to vasectomy acceptors in Thailand was 24.5:1; in 1978 the ratio was 2.8:1. Several factors are responsible for this change. First, a national family planning program to support voluntary family planning started in 1970 and lowered the population growth rate from 3.2% in 1973 to 2.1% in 1982. Second, the desired family size in Thailand is 3 and it is generally agreed that the solution is voluntary sterilization as a more cost effective fertility control method. Thirdly, misunderstandings about vasectomy were cleared up through media campaigns which cleared the way for greater acceptance. Fourth, in 1975 special clinics at big hospitals and a mobile unit were set up to perform vasectomies. Lastly, a group of nongovernment organizations has been set up, such as the Thai Association for Voluntary Sterilization, to provide the infrastructure for vasectomy campaigns. Requests for vasectomy reversals have, expectedly, increased as well, usually caused by marriage, child's death, improved finances, and psychosexual health. In a recent study of 32 cases, positive sperm reappearance after vas reanastomosis was found in 71.4% and the pregnancy rate was 52.3%.

  17. Study on the effects of electrolytes and solvents in the determination of quaternary ammonium ions by nonaqueous capillary electrophoresis with contactless conductivity detection.

    PubMed

    Buglione, Lucia; See, Hong Heng; Hauser, Peter C

    2013-01-01

    A study on the separation of lipophilic quaternary ammonium cations in NACE coupled with contactless conductivity detection (NACE-C(4)D) is presented. The suitability of different salts dissolved in various organic solvents as running electrolytes in NACE-C(4)D was investigated. A solvent mixture of methanol/acetonitrile at a ratio of 90%:10% v/v showed the best results. Deoxycholic acid sodium salt as BGE was found to provide exceptional high stability with low baseline noise that leads to highest S/N ratios for the target analytes among all BGEs tested. Under the optimum conditions, capillaries with different internal diameters were examined and an id of 50 μm was found to give best detection sensitivity. The proposed method was validated and showed good linearity in the range from 2.5 to 200 μM, low limits of detection (0.1-0.7 μM) and acceptable reproducibility of peak area (intraday RSD 0.1-0.7%, n = 3; interday RSD 5.9-9.4%, n = 3). © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Cost-effectiveness of antiplatelet drugs after percutaneous coronary intervention

    PubMed Central

    Wisløff, Torbjørn; Atar, Dan

    2016-01-01

    Abstract Aims Clopidogrel has, for long time, been accepted as the standard treatment for patients who have undergone a percutaneous coronary intervention (PCI). The introduction of prasugrel—and more recently, ticagrelor—has introduced a decision-making problem for clinicians and governments worldwide: to use the cheaper clopidogrel or the more effective, and also more expensive prasugrel or ticagrelor. We aim to give helpful contributions to this debate by analysing the cost-effectiveness of clopidogrel, prasugrel, and ticagrelor compared with each other. Methods and results We modified a previously developed Markov model of cardiac disease progression. In the model, we followed up cohorts of patients who have recently had a PCI until 100 years or death. Possible events are revascularization, bleeding, acute myocardial infarction, and death. Our analysis shows that ticagrelor is cost-effective in 77% of simulations at an incremental cost-effectiveness ratio of €7700 compared with clopidogrel. Ticagrelor was also cost-effective against prasugrel at a cost-effectiveness ratio of €7800. Given a Norwegian cost-effectiveness threshold of €70 000, both comparisons appear to be clearly cost-effective in favour of ticagrelor. Conclusion Ticagrelor is cost-effective compared with both clopidogrel and prasugrel for patients who have undergone a PCI. PMID:29474586

  19. QSAR analysis for nano-sized layered manganese-calcium oxide in water oxidation: An application of chemometric methods in artificial photosynthesis.

    PubMed

    Shahbazy, Mohammad; Kompany-Zareh, Mohsen; Najafpour, Mohammad Mahdi

    2015-11-01

    Water oxidation is among the most important reactions in artificial photosynthesis, and nano-sized layered manganese-calcium oxides are efficient catalysts toward this reaction. Herein, a quantitative structure-activity relationship (QSAR) model was constructed to predict the catalytic activities of twenty manganese-calcium oxides toward water oxidation using multiple linear regression (MLR) and genetic algorithm (GA) for multivariate calibration and feature selection, respectively. Although there are eight controlled parameters during synthesizing of the desired catalysts including ripening time, temperature, manganese content, calcium content, potassium content, the ratio of calcium:manganese, the average manganese oxidation state and the surface of catalyst, by using GA only three of them (potassium content, the ratio of calcium:manganese and the average manganese oxidation state) were selected as the most effective parameters on catalytic activities of these compounds. The model's accuracy criteria such as R(2)test and Q(2)test in order to predict catalytic rate for external test set experiments; were equal to 0.941 and 0.906, respectively. Therefore, model reveals acceptable capability to anticipate the catalytic activity. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Acceptability of School-Based Health Centers for Human Papillomavirus Vaccination Visits: A Mixed-Methods Study

    ERIC Educational Resources Information Center

    Hansen, Caitlin E.; Okoloko, Edirin; Ogunbajo, Adedotun; North, Anna; Niccolai, Linda M.

    2017-01-01

    Background: Countries with high human papillomavirus (HPV) vaccination rates have achieved this success largely through school-based vaccination. Using school-based health centers (SBHCs) in the United States, where HPV vaccine remains underutilized, could improve uptake. In this mixed-methods study, we examined acceptability, facilitators, and…

  1. Systematic Development and Validation of a Thin-Layer Densitometric Bioanalytical Method for Estimation of Mangiferin Employing Analytical Quality by Design (AQbD) Approach

    PubMed Central

    Khurana, Rajneet Kaur; Rao, Satish; Beg, Sarwar; Katare, O.P.; Singh, Bhupinder

    2016-01-01

    The present work aims at the systematic development of a simple, rapid and highly sensitive densitometry-based thin-layer chromatographic method for the quantification of mangiferin in bioanalytical samples. Initially, the quality target method profile was defined and critical analytical attributes (CAAs) earmarked, namely, retardation factor (Rf), peak height, capacity factor, theoretical plates and separation number. Face-centered cubic design was selected for optimization of volume loaded and plate dimensions as the critical method parameters selected from screening studies employing D-optimal and Plackett–Burman design studies, followed by evaluating their effect on the CAAs. The mobile phase containing a mixture of ethyl acetate : acetic acid : formic acid : water in a 7 : 1 : 1 : 1 (v/v/v/v) ratio was finally selected as the optimized solvent for apt chromatographic separation of mangiferin at 262 nm with Rf 0.68 ± 0.02 and all other parameters within the acceptance limits. Method validation studies revealed high linearity in the concentration range of 50–800 ng/band for mangiferin. The developed method showed high accuracy, precision, ruggedness, robustness, specificity, sensitivity, selectivity and recovery. In a nutshell, the bioanalytical method for analysis of mangiferin in plasma revealed the presence of well-resolved peaks and high recovery of mangiferin. PMID:26912808

  2. A new method for parameter estimation in nonlinear dynamical equations

    NASA Astrophysics Data System (ADS)

    Wang, Liu; He, Wen-Ping; Liao, Le-Jian; Wan, Shi-Quan; He, Tao

    2015-01-01

    Parameter estimation is an important scientific problem in various fields such as chaos control, chaos synchronization and other mathematical models. In this paper, a new method for parameter estimation in nonlinear dynamical equations is proposed based on evolutionary modelling (EM). This will be achieved by utilizing the following characteristics of EM which includes self-organizing, adaptive and self-learning features which are inspired by biological natural selection, and mutation and genetic inheritance. The performance of the new method is demonstrated by using various numerical tests on the classic chaos model—Lorenz equation (Lorenz 1963). The results indicate that the new method can be used for fast and effective parameter estimation irrespective of whether partial parameters or all parameters are unknown in the Lorenz equation. Moreover, the new method has a good convergence rate. Noises are inevitable in observational data. The influence of observational noises on the performance of the presented method has been investigated. The results indicate that the strong noises, such as signal noise ratio (SNR) of 10 dB, have a larger influence on parameter estimation than the relatively weak noises. However, it is found that the precision of the parameter estimation remains acceptable for the relatively weak noises, e.g. SNR is 20 or 30 dB. It indicates that the presented method also has some anti-noise performance.

  3. Resourcefulness Training for Women Dementia Caregivers: Acceptability and Feasibility of Two Methods.

    PubMed

    Zauszniewski, Jaclene A; Lekhak, Nirmala; Napoleon, Betty; Morris, Diana L

    2016-01-01

    Almost 10 million women in the United States are caregivers for elders with dementia and many experience extreme stress that compromises their health. Acceptable and feasible interventions to teach them resourcefulness skills for managing stress may improve their health and facilitate continued caregiving. This study examined two commonly used methods for practicing skills taught during resourcefulness training (RT) to women caregivers of elders with dementia (n=63): journaling and digital voice recording. It also explored whether providing caregivers a choice between the two methods made it more acceptable or feasible. Qualitative and quantitative data were collected before, during, and after RT. Caregivers who recorded used more words (M=5446) but recorded fewer days (M=17) than those who journaled (M=2792 words and M=27 days). Similar concerns in relation to time management and practice method were expressed by women caregivers irrespective of practice method (journal versus recorder) or random versus choice condition. While journaling was more frequent than recording, more words were expressed during recordings. Perceived stress and depressive symptoms were unrelated to the number of practice days or word counts, suggesting RT acceptability and feasibility even for highly stressed or depressed caregivers. Because intervention feasibility is important for RT effectiveness testing, alternatives to the journaling and recording methods for practicing RT skills should be considered.

  4. 7 CFR 770.3 - Eligibility requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... without adequate uncommitted funds, based on Generally Accepted Accounting Principles, or another financial accounting method acceptable to Secretary of Interior to acquire lands or interests therein within...

  5. A pilot study on the functional performance and acceptability of an innovative female condom (Wondaleaf®) in Malaysia

    PubMed Central

    Wong, Ee-Lynn; Tnay, Jessie Koh-Sing

    2018-01-01

    Background Female condom (FC) has been available for over 30 years, but it still lacks wide acceptability. To overcome misdirection and invagination occurring in FC and to provide a wider area of protection, Wondaleaf® (WL), a new-generation adhesive FC, was recently invented. This pioneering study sought to assess the acceptability and functional performance of WL among Malaysian women. Methods A mixed method survey was conducted in three cities of Malaysia, recruiting sexually active heterosexual women, aged 18–50, by snowball sampling method. Participants were provided with WL and initially surveyed to rate its performance in five coital usages over 2 months. After that, the participants underwent a second survey to rate their satisfaction and acceptability toward WL. Descriptive statistics on clinical failure rates were tabulated with correlational analysis performed to identify major variables contributing to WL’s functional performance and acceptability. Results Out of the 51 enrolled participants, 31 women completed the required surveys. WL’s total clinical failure rate was 2.60% (out of 155 condom uses) with above-average ratings of functional performance. The ease of use significantly correlated with ratings of no slippage and no misdirection. The confidence in WL’s safety features significantly correlated with a sense of empowerment and protection. Conclusion WL has a relatively low risk of clinical failures and an overall favorable acceptability among Malaysian women. However, this study also showed that its future usage largely depends on partner acceptability. It may have the potential of complementing the existing barrier toward contraceptive use. Further studies are needed to understand the global acceptability of WL. PMID:29440937

  6. Optimal temperature ladders in replica exchange simulations

    NASA Astrophysics Data System (ADS)

    Denschlag, Robert; Lingenheil, Martin; Tavan, Paul

    2009-04-01

    In replica exchange simulations, a temperature ladder with N rungs spans a given temperature interval. Considering systems with heat capacities independent of the temperature, here we address the question of how large N should be chosen for an optimally fast diffusion of the replicas through the temperature space. Using a simple example we show that choosing average acceptance probabilities of about 45% and computing N accordingly maximizes the round trip rates r across the given temperature range. This result differs from previous analyses which suggested smaller average acceptance probabilities of about 23%. We show that the latter choice maximizes the ratio r/N instead of r.

  7. Effect of soft tissue laxity of the knee joint on limb alignment correction in open-wedge high tibial osteotomy.

    PubMed

    Lee, Dae-Hee; Park, Sung-Chul; Park, Hyung-Joon; Han, Seung-Beom

    2016-12-01

    Open-wedge high tibial osteotomy (HTO) cannot always accurately correct limb alignment, resulting in under- or over-correction. This study assessed the relationship between soft tissue laxity of the knee joint and alignment correction in open-wedge HTO. This prospective study involved 85 patients (86 knees) undergoing open-wedge HTO for primary medial osteoarthritis. The mechanical axis (MA), weight-bearing line (WBL) ratio, and joint line convergence angle (JLCA) were measured on radiographs preoperatively and after 6 months, and the differences between the pre- and post-surgery values were calculated. Post-operative WBL ratios of 57-67 % were classified as acceptable correction. WBL ratios <57 and >67 % were classified as under- and over-corrections, respectively. Preoperative JLCA correlated positively with differences in MA (r = 0.358, P = 0.001) and WBL ratio (P = 0.003). Difference in JLCA showed a stronger correlation than preoperative JLCA with differences in MA (P < 0.001) and WBL ratio (P < 0.001). Difference in JLCA was the only predictor of both difference in MA (P < 0.001) and difference in WBL ratio (P < 0.001). The difference between pre- and post-operative JLCA differed significantly between the under-correction, acceptable-correction, and over-correction groups (P = 0.033). Preoperative JLCA, however, did not differ significantly between the three groups. Neither preoperative JLCA nor difference in JLCA correlated with change in posterior slope. Preoperative degree of soft tissue laxity in the knee joint was related to the degree of alignment correction, but not to alignment correction error, in open-wedge HTO. Change in soft tissue laxity around the knee from before to after open-wedge HTO correlated with both correction amount and correction error. Therefore, a too large change in JLCA from before to after open-wedge osteotomy may be due to an overly large reduction in JLCA following osteotomy, suggesting alignment over-correction during surgery. II.

  8. End-product quality characteristics and consumer response of chickpea flour-based gluten-free muffins containing corn starch and egg white.

    PubMed

    Alvarez, María Dolores; Herranz, Beatriz; Jiménez, María José; Canet, Wenceslao

    2017-12-01

    The objective of this work was to study changes in technological characteristics and sensory properties of gluten-free muffins when using chickpea flour (CF) alone and/or with partial CF replacement by corn starch (CS). The effect of partial whole egg replacement by egg white (EW) was also investigated. Four different CF:CS ratios (100:0, 75:25, 50:50, and 25:75) were used in formulations with and without incorporated EW, and compared with wheat flour (WF) muffins (0:0). Muffins prepared from CF alone had lower hardness, springiness, cohesiveness, chewiness, and resilience than control ones. However, reducing protein content by CS addition significantly increased texture profile analysis parameters of muffin crumb. Muffins prepared with 25:75 ratio had a structure with springiness similar to muffins made with WF but were too hard. Reducing whole egg content by partial replacement with EW also significantly increased muffin hardness. Flash profile performed by consumers showed a clear discrimination of muffins according to CF:CS ratio. Muffins containing both CF and CS at 50:50 ratio had the same high overall acceptability and purchase intention as gluten ones. Gluten-free CF-based muffins of satisfactory quality can be manufactured by CS incorporation, either with or without EW. By decreasing and increasing protein and starch contents of chickpea flour (CF) by incorporation of corn starch (CS), muffins formulated from a combination of CF and CS at different CF:CS ratios, either with or without partial replacement of whole egg with egg white, result in high-quality muffins with similar technological and sensory characteristics to those of their gluten counterparts. Sensory overall acceptability and purchase intention of muffins made with a 50:50 ratio did not differ significantly from those of the controls. These findings will benefit celiac population, while promoting the value and utilization of pulses through muffins. © 2017 Wiley Periodicals, Inc.

  9. Acceptability of Daily Use of Free Oral Pre-exposure Prophylaxis (PrEP) Among Transgender Women Sex Workers in Shenyang, China.

    PubMed

    Wang, Zixin; Lau, Joseph T F; Yang, Xueying; Cai, Yong; Gross, Danielle L; Ma, Tiecheng; Liu, Yan

    2017-12-01

    This study investigated the acceptability of daily use of free oral pre-exposure prophylaxis (PrEP) and associated factors among transgender women sex workers in Shenyang, China, following a briefing on PrEP. A total of 183 HIV negative or sero-status unknown participants completed the cross-sectional survey. The prevalence of acceptability of daily use of free oral PrEP was 61.2%. Adjusting for education level and monthly income, variables on negative attitudes toward PrEP (i.e., having concerns about the side-effects of PrEP) [Adjusted odds ratios (AOR): 0.26], perceived subjective norms (i.e., perceiving support from male partners to take PrEP) (AOR: 2.08), and perceived behavioral control (e.g., perceiving complete control over using PrEP) (AOR: 2.10-16.72) were significantly associated with acceptability of daily use of free oral PrEP. In addition, experiencing violence during sex work, perceived risk of contracting HIV from clients and probable anxiety were also significant. Future PrEP promotion campaigns should consider these factors.

  10. Physical-Chemical Characterization of Fruit Purees and Relationship with Sensory Analysis Carried out by Infants (12 to 24 mo).

    PubMed

    Inarejos-García, A M; Mancebo-Campos, V; Cañizares, P; Llanos, J

    2015-05-01

    Fruit purees are one of the foods earliest introduced foods in infants' diet during the complementary period. The rheological characteristics together with the sensory analysis are decisive factors for the acceptance of the food product by the infant. The sensory analysis of three commercial fruit purees (mixed fruits, pear, and plum) was studied by employing a new objective sensory parameter named as SAIR (Sensory Acceptance by Infants Ratio), which is the quotient between the percentage of puree consumed (%) by the time (seconds) throughout the storage time. In parallel, the rheological characteristics of the purees were analyzed in order to obtain a relationship with the SAIR parameter. It was proved that the best acceptance of the product (higher SAIR) was observed for such purees showing a lower apparent viscosity (lower consistency index, "K") and a less pseudoplastic behavior (higher flow behavior index, "n"). These results may help to obtain higher acceptance values based on easy obtainable and objective parameters. © 2015 Institute of Food Technologists®

  11. Parametric synthesis of a robust controller on a base of mathematical programming method

    NASA Astrophysics Data System (ADS)

    Khozhaev, I. V.; Gayvoronskiy, S. A.; Ezangina, T. A.

    2018-05-01

    Considered paper is dedicated to deriving sufficient conditions, linking root indices of robust control quality with coefficients of interval characteristic polynomial, on the base of mathematical programming method. On the base of these conditions, a method of PI- and PID-controllers, providing aperiodic transient process with acceptable stability degree and, subsequently, acceptable setting time, synthesis was developed. The method was applied to a problem of synthesizing a controller for a depth control system of an unmanned underwater vehicle.

  12. Method for reduction of selected ion intensities in confined ion beams

    DOEpatents

    Eiden, Gregory C.; Barinaga, Charles J.; Koppenaal, David W.

    1998-01-01

    A method for producing an ion beam having an increased proportion of analyte ions compared to carrier gas ions is disclosed. Specifically, the method has the step of addition of a charge transfer gas to the carrier analyte combination that accepts charge from the carrier gas ions yet minimally accepts charge from the analyte ions thereby selectively neutralizing the carrier gas ions. Also disclosed is the method as employed in various analytical instruments including an inductively coupled plasma mass spectrometer.

  13. Method for reduction of selected ion intensities in confined ion beams

    DOEpatents

    Eiden, G.C.; Barinaga, C.J.; Koppenaal, D.W.

    1998-06-16

    A method for producing an ion beam having an increased proportion of analyte ions compared to carrier gas ions is disclosed. Specifically, the method has the step of addition of a charge transfer gas to the carrier analyte combination that accepts charge from the carrier gas ions yet minimally accepts charge from the analyte ions thereby selectively neutralizing the carrier gas ions. Also disclosed is the method as employed in various analytical instruments including an inductively coupled plasma mass spectrometer. 7 figs.

  14. Assessing Abuse Risk beyond Self-Report: Analog Task of Acceptability of Parent-Child Aggression

    ERIC Educational Resources Information Center

    Rodriguez, Christina M.; Russa, Mary Bower; Harmon, Nancy

    2011-01-01

    Objectives: The present investigation reports on the development and initial validation of a new analog task, the Parent-Child Aggression Acceptability Movie Task (P-CAAM), intended to assess respondents' acceptance of parent-child aggression, including both physical discipline and physical abuse. Methods: Two independent samples were utilized to…

  15. High School Students' Perceptions of Evolution Instruction: Acceptance and Evolution Learning Experiences

    ERIC Educational Resources Information Center

    Donnelly, Lisa A.; Kazempour, Mahsa; Amirshokoohi, Aidin

    2009-01-01

    Evolution is an important and sometimes controversial component of high school biology. In this study, we used a mixed methods approach to explore students' evolution acceptance and views of evolution teaching and learning. Students explained their acceptance and rejection of evolution in terms of evidence and conflicts with religion and…

  16. Limits of acceptable change as tool for tourism development sustainability in Pangandaran West Java

    NASA Astrophysics Data System (ADS)

    Komsary, K. C.; Tarigan, W. P.; Wiyana, T.

    2018-03-01

    Pangandaran since 2006 has become a model of sustainable tourism development. A program aimed to empower local communities to prepare work plans and activities to enrich the various potential development of sustainable tourism. By empowering local community, business competition has led to the undesired development of the tourism sector. This becomes the concern of the negative impact of physical changes in the area. This study aims to identify and measure the acceptable changes (limits of acceptable change-LAC) of tourism development in Pangandaran to remain adaptable as a tourist attraction. This study considers how to determine acceptable levels of impact that occurs in the Pangandaran area. This method involves stakeholders in determining the values, issues, and concerns the acceptable levels of impact for this region. The result of acceptance rate then compared with the effects of the current state. Through review and analysis methods used in this study, the LAC situation in Pangandaran outlined. Results from this study are expected to identify indicators of sustainable development of tourism sector through LAC approach.

  17. Japanese Adaptation of the Stroke and Aphasia Quality of Life Scale-39 (SAQOL-39): Comparative Study among Different Types of Aphasia.

    PubMed

    Kamiya, Akane; Kamiya, Kentaro; Tatsumi, Hiroshi; Suzuki, Makihiko; Horiguchi, Satoshi

    2015-11-01

    We have developed a Japanese version of the Stroke and Aphasia Quality of Life Scale-39 (SAQOL-39), designated as SAQOL-39-J, and used psychometric methods to examine its acceptability and reliability. The acceptability and reliability of SAQOL-39-J, which was developed from the English version using a standard translation and back-translation method, were examined in 54 aphasia patients using standard psychometric methods. The acceptability and reliability of SAQOL-39-J were then compared among patients with different types of aphasia. SAQOL-39-J showed good acceptability, internal consistency (Cronbach's α score = .90), and test-retest reliability (intraclass correlation coefficient = .97). Broca's aphasia patients showed the lowest total scores and communication scores on SAQOL-39-J. The Japanese version of SAQOL-39, SAQOL-39-J, provides acceptable and reliable data in Japanese stroke patients with aphasia. Among different types of aphasia, Broca's aphasia patients had the lowest total and communication SAQOL-39-J scores. Further studies are needed to assess the effectiveness of health care interventions on health-related quality of life in this population. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  18. Effects of disciplinary cultures of researchers and research trainees on the acceptability of nanocarriers for drug delivery in different contexts of use: a mixed-methods study

    NASA Astrophysics Data System (ADS)

    Chenel, Vanessa; Boissy, Patrick; Cloarec, Jean-Pierre; Patenaude, Johane

    2015-04-01

    The acceptability of nanomedical applications, which have the potential to generate ethical and societal impacts, is a significant factor in the deployment of nanomedicine. A lack of fit between nanomedical applications and society's values may result from a partial consideration of such impacts. New approaches for technological evaluation focused on impact perception, acceptance, and acceptability are needed to go beyond traditional technology assessment approaches used with nanotechnology, which focus mainly on toxicological and safety criteria. Using a new evaluative approach based on perceived impacts of nanotechnology, the objective of this study was to assess perceptions among researchers and research trainees familiar with emergent technologies and from different disciplinary background the scope of acceptability judgments made towards the use of nanocarriers. This mixed-methods study was based on scenarios presenting two types of drug-delivery nanocarriers (carbon, synthetic DNA) in two contexts of use (lung cancer treatment, seasonal flu treatment). Researchers and research trainees in the natural sciences and engineering, and the social sciences and the humanities were invited by email to take part in this project. An online questionnaire followed by semi-directed interviews allowed characterization of disciplinary divergences regarding to impact perception, acceptance, and acceptability of the scenarios. The results suggest that impact perception is influenced by disciplinary culture. Also, trends can be seen between respondents' profiles and variables of acceptance and acceptability, and certain components of the acceptability judgement are specific to each disciplinary culture. The acknowledgment and consideration of these disciplinary divergences could allow, among others, for opening up interdisciplinary dialogue on matters related to the acceptability of nanomedical applications and their developments.

  19. Effects of disciplinary cultures of researchers and research trainees on the acceptability of nanocarriers for drug delivery in different contexts of use: a mixed-methods study.

    PubMed

    Chenel, Vanessa; Boissy, Patrick; Cloarec, Jean-Pierre; Patenaude, Johane

    The acceptability of nanomedical applications, which have the potential to generate ethical and societal impacts, is a significant factor in the deployment of nanomedicine. A lack of fit between nanomedical applications and society's values may result from a partial consideration of such impacts. New approaches for technological evaluation focused on impact perception, acceptance, and acceptability are needed to go beyond traditional technology assessment approaches used with nanotechnology, which focus mainly on toxicological and safety criteria. Using a new evaluative approach based on perceived impacts of nanotechnology, the objective of this study was to assess perceptions among researchers and research trainees familiar with emergent technologies and from different disciplinary background the scope of acceptability judgments made towards the use of nanocarriers. This mixed-methods study was based on scenarios presenting two types of drug-delivery nanocarriers (carbon, synthetic DNA) in two contexts of use (lung cancer treatment, seasonal flu treatment). Researchers and research trainees in the natural sciences and engineering, and the social sciences and the humanities were invited by email to take part in this project. An online questionnaire followed by semi-directed interviews allowed characterization of disciplinary divergences regarding to impact perception, acceptance, and acceptability of the scenarios. The results suggest that impact perception is influenced by disciplinary culture. Also, trends can be seen between respondents' profiles and variables of acceptance and acceptability, and certain components of the acceptability judgement are specific to each disciplinary culture. The acknowledgment and consideration of these disciplinary divergences could allow, among others, for opening up interdisciplinary dialogue on matters related to the acceptability of nanomedical applications and their developments.

  20. Breast-feeding duration: influence on taste acceptance over the first year of life.

    PubMed

    Schwartz, Camille; Chabanet, Claire; Laval, Caroline; Issanchou, Sylvie; Nicklaus, Sophie

    2013-03-28

    Early feeding experiences, e.g. related to milk feeding, can affect later food and taste preferences. However, consequences of breast-feeding on taste acceptance are under-investigated. The objective of the present study was to examine the impact of exclusive breast-feeding duration (DEB) on taste acceptance at 6 and 12 months in the same infants (n 122). Mothers recorded the DEB. Acceptance of solutions of each of the five basic tastes relative to water was evaluated in the laboratory at 6 and 12 months by the ingestion ratio (IR). Kendall correlations were calculated between the DEB and the IR. Only 16 % completed at least 6 months of exclusive breast-feeding; 79 % had begun complementary feeding by 6 months. At 6 months, infants preferred sweet, salty and umami solutions over water and were indifferent to sour and bitter solutions. The longer an infant was breast-fed, the more s/he accepted the umami solution at 6 months. At 12 months, infants preferred sweet and salty solutions over water and were indifferent to sour, bitter and umami solutions. The relationship between the DEB and acceptance of the umami solution was not observed at 12 months. No relationship was observed between the DEB and sweet, salty, sour and bitter taste acceptance at 6 or 12 months. The association between the DEB and umami taste acceptance at 6 months may relate to the higher glutamate content of human milk compared with formula milk. Beyond the acknowledged metabolic benefits of breast-feeding, this suggests that prolonged breast-feeding could also be associated with an impact on sensory preference at the beginning of complementary feeding.

  1. Acceptability of oral versus rectal HIV preexposure prophylaxis among men who have sex with men and transgender women in Peru.

    PubMed

    Peinado, Jesus; Lama, Javier R; Galea, Jerome T; Segura, Patricia; Casapia, Martin; Ortiz, Abner; Montano, Silvia M; Kochel, Tadeusz; Sánchez, Jorge

    2013-01-01

    Oral preexposure prophylaxis (PrEP) with antiretrovirals (ARVs) is at the forefront of biomedical HIV prevention research, and ARVs are also being tested for rectal administration to target people practicing unprotected receptive anal intercourse (URAI) and at risk of HIV infection. This study assessed the acceptability of daily oral PrEP and rectal PrEP during URAI among men who have sex with men (MSM) and transgender women (TGW) in Peru. During the 2008 HIV sentinel surveillance survey conducted in 3 Peruvian cities (Lima, Iquitos, and Pucallpa), MSM and TGW reported being "versatile," "most of the time receptive," and "exclusively receptive" during anal sex behavior where surveyed on their acceptability of oral and rectal PrEP. Among 532 individuals, high acceptance of either oral (96.2%) or rectal (91.7%) PrEP products was reported. If both products were efficacious/available, 28.6% would prefer a pill, 57.3% a rectal lubricant, and 14.1% either. A trend toward higher acceptance was observed as receptive anal sex behavior exclusivity rose (P = .013). Being receptive most of the time (adjusted odds ratio [aOR]: 9.1, P = .01) and exclusively receptive (aOR: 7.5, P = .01), compared to being versatile, were independently associated with oral PrEP acceptability. A similar association was found with the acceptability of rectal formulations (aOR: 2.3, P = .07; and aOR: 2.5, P = .02; respectively). Oral and rectal PrEP were highly acceptable among Peruvian MSM and TGW, particularly among those at the highest HIV infection risk. These data can guide the implementation of PrEP programs in Peru and similar settings and populations.

  2. Consumers' sensitivity to androstenone and the evaluation of different cooking methods to mask boar taint.

    PubMed

    Borrisser-Pairó, F; Panella-Riera, N; Gil, M; Kallas, Z; Linares, M B; Egea, M; Garrido, M D; Oliver, M A

    2017-01-01

    Boar taint is an unpleasant odour and flavour present in some entire male pigs that is due to the presence of androstenone and skatole. The aim of the study was to assess the sensitivity of 150 consumers to androstenone and to compare the acceptability and liking of meat from castrated and entire pigs, cooked with different cooking methods. Meat samples consisted of loins from castrated (CM) and entire male pigs (EM) with high levels of androstenone cooked by two cooking methods: sous-vide and fried/breaded with garlic and parsley. Consumers evaluated smell and flavour acceptability, and overall liking of CM and EM for each cooking method. The results of the study showed that dislike of androstenone odour increased significantly with sensitivity. The results of acceptability and overall liking were similar in CM and EM for both cooking methods. Therefore, the two cooking methods used in the study may be useful to mask boar taint. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Efficacy and acceptance of professional dental cleaning among nursing home residents.

    PubMed

    Barbe, Anna Greta; Kottmann, Hannah Elisa; Hamacher, Stefanie; Derman, Sonja Henny Maria; Noack, Michael Johannes

    2018-05-13

    To determine the impact of general and oral health status of nursing home residents in Germany on efficacy and acceptance of professional dental cleaning performed by a dental nurse. Participants (N = 41; mean age 83 ± 8 years) living in a nursing home were included. Personal and general health, oral health, oral hygiene habits, and needs were investigated. Individual acceptance regarding professional dental cleaning via different devices (scaler, interdental brushes, ultrasonic cleaning) was assessed, as was the efficacy of this method using after-cleaning indices. Oral health among nursing home residents was impaired and independent from dementia status. Most residents (33/41) performed oral hygiene procedures independently and showed better index values than those in need of external help. Residents requiring help with oral hygiene showed increased risk profiles (higher age, more often immobile, demented, more xerostomia). The dental cleaning procedure required a mean time of 37 ± 11 min, was widely accepted (36/41), and achieved clean results (plaque index 0.1 ± 0.5, oral hygiene index 0.2 ± 1.6, Volpe-Manhold index 0.4 ± 1.6); food residues were reduced to 0 independent from cognitive status. Regarding the cleaning methods, scalers were accepted best without difference between demented and non-demented residents. Professional dental cleaning in nursing homes is an accepted and efficacious oral hygiene procedure among nursing home residents. Professional dental cleaning is an efficacious and accepted method as a first step in line with strategies to improve oral health and should be considered in nursing home residents.

  4. Acceptability and Feasibility of a Shared Decision-Making Model in Work Rehabilitation: A Mixed-Methods Study of Stakeholders' Perspectives.

    PubMed

    Coutu, Marie-France; Légaré, France; Durand, Marie-José; Stacey, Dawn; Labrecque, Marie-Elise; Corbière, Marc; Bainbridge, Lesley

    2018-04-16

    Purpose To establish the acceptability and feasibility of implementing a shared decision-making (SDM) model in work rehabilitation. Methods We used a sequential mixed-methods design with diverse stakeholder groups (representatives of private and public employers, insurers, and unions, as well as workers having participated in a work rehabilitation program). First, a survey using a self-administered questionnaire enabled stakeholders to rate their level of agreement with the model's acceptability and feasibility and propose modifications, if necessary. Second, eight focus groups representing key stakeholders (n = 34) and four one-on-one interviews with workers were conducted, based on the questionnaire results. For each stakeholder group, we computed the percentage of agreement with the model's acceptability and feasibility and performed thematic analyses of the transcripts. Results Less than 50% of each stakeholder group initially agreed with the overall acceptability and feasibility of the model. Stakeholders proposed 37 modifications to the objectives, 17 to the activities, and 39 to improve the model's feasibility. Based on in-depth analysis of the transcripts, indicators were added to one objective, an interview guide was added as proposed by insurers to ensure compliance of the SDM process with insurance contract requirements, and one objective was reformulated. Conclusion Despite initially low agreement with the model's acceptability on the survey, subsequent discussions led to three minor changes and contributed to the model's ultimate acceptability and feasibility. Later steps will involve assessing the extent of implementation of the model in real rehabilitation settings to see if other modifications are necessary before assessing its impact.

  5. A Search for the Standard Model Higgs Boson in CDF II Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lockwitz, Sarah E.

    2012-01-01

    This dissertation presents a search for the standard model Higgs boson in the associated production process pmore » $$\\bar{p}$$ → ZH → e +e -b$$\\bar{b}$$. Data amounting to an integrated luminosity of 7.5 fb -1 at √s = 1.96 TeV collected at the Collider Detector at Fermilab (CDF) at the Tevatron are analyzed. Two objectives are pursued in the methods applied: maximize acceptance, and distinguish the signal from background. The first aim is met by applying a neural-network-based electron identi cation and considering multiple electron triggers in an effort to improve Z acceptance. In an attempt to maximize the Higgs acceptance, three b quark identification schemes are used allowing for varying event conditions. The latter goal is met by employing more multivariate techniques. First, the dijet mass resolution is improved by a neural network. Then, both single variables and boosted decision tree outputs are fed into a segmented final discriminant simultaneously isolating the signal-like events from the Z with additional jets background and the kinematically di erent tt background. Good agreement is seen with the null hypothesis and upper production cross section ( ZH) times branching ratio (BR(H →b $$\\bar{b}$$)) limits are set for 11 mass hypotheses between 100 and 150 GeV/c 2 at the 95% confidence level. For a Higgs boson mass of 115 GeV/c 2, this channel sets an observed (expected) upper limit of 3.9 (5.8) times the standard model value of ZH BR(H → b $$\\bar{b}$$). The inclusion of this channel within the combined CDF and Tevatron limits is discussed.« less

  6. Efficient Production of Retroviruses Using PLGA/bPEI-DNA Nanoparticles and Application for Reprogramming Somatic Cells

    PubMed Central

    Do, Eun Kyoung; Cheon, Hyo Cheon; Heo, Soon Chul; Kwon, Yang Woo; Jeong, Geun Ok; Kim, Ba Reun; Kim, Jae Ho

    2013-01-01

    Reprogramming of somatic cells to pluripotent cells requires the introduction of factors driving fate switches. Viral delivery has been the most efficient method for generation of induced pluripotent stem cells. Transfection, which precedes virus production, is a commonly-used process for delivery of nucleic acids into cells. The aim of this study is to evaluate the efficiency of PLGA/ bPEI nanoparticles in transfection and virus production. Using a modified method of producing PLGA nanoparticles, PLGA/bPEI-DNA nanoparticles were examined for transfection efficiency and virus production yield in comparison with PLGA-DNA, bPEI-DNA nanoparticles or liposome-DNA complexes. After testing various ratios of PLGA, bPEI, and DNA, the ratio of 6:3:1 (PLGA:bPEI:DNA, w/w/w) was determined to be optimal, with acceptable cellular toxicity. PLGA/bPEI-DNA (6:3:1) nanoparticles showed superior transfection efficiency, especially in multiple gene transfection, and viral yield when compared with liposome-DNA complexes. The culture supernatants of HEK293FT cells transfected with PLGA/bPEI-DNA of viral constructs containing reprogramming factors (Oct4, Sox2, Klf4, or c-Myc) successfully and more efficiently generated induced pluripotent stem cell colonies from mouse embryonic fibroblasts. These results strongly suggest that PLGA/bPEI-DNA nanoparticles can provide significant advantages in studying the effect of multiple factor delivery such as in reprogramming or direct conversion of cell fate. PMID:24098810

  7. Fabrication and Properties of Micro-Nanoencapsulated Phase Change Materials for Internally-Cooled Liquid Desiccant Dehumidification

    PubMed Central

    Niu, Xiaofeng; Xu, Qing; Zhang, Yi; Zhang, Yue; Yan, Yufeng; Liu, Tao

    2017-01-01

    Micro-nanoencapsulated phase change materials (M-NEPCMs) are proposed to be useful in liquid desiccant dehumidification by restraining the temperature rise in the moisture-removal process and improving the dehumidification efficiency. In this paper, the n-octadecane M-NEPCMs with desirable thermal properties for internally-cooled dehumidification were fabricated by using compound emulsifiers through the in-situ polymerization method. Melamine-formaldehyde resin was used as the shell material. The effects of the mixing ratio, emulsification methods and amount of the compound emulsifiers on the morphology, size and thermal properties of the M-NEPCMs were investigated experimentally. The optimum weight mixing ratio of the compound emulsifiers is SDS (sodium dodecyl sulfate):Tween80 (polyoxyethylene sorbitan monooleate):Span80 (sorbitan monooleate) = 0.1:0.6:0.3, which achieves the best stability of the n-octadecane emulsion. When the compound emulsifiers are 10 wt. % of the core material, the melting enthalpy of M-NEPCMs reaches its maximum of 145.26 J/g of capsules, with an encapsulation efficiency of 62.88% and a mean diameter of 636 nm. The sub-cooling of the prepared M-NEPCMs is lower than 3 °C, with an acceptable thermal reliability after the thermal cycling test. A pre-emulsification prior to the addition of deionized water in the emulsification is beneficial to the morphology of the capsules, as the phase change enthalpy can be increased by 123.7%. PMID:28468282

  8. Exploring the validity of HPQ-based presenteeism measures to estimate productivity losses in the health and education sectors.

    PubMed

    Scuffham, Paul A; Vecchio, Nerina; Whiteford, Harvey A

    2014-01-01

    Illness-related presenteeism (suboptimal work performance) may be a significant factor in worker productivity. Until now, there has been no generally accepted best method of measuring presenteeism across different industries and occupations. This study sought to validate the Health and Work Performance Questionnaire (HPQ)-based measure of presenteeism across occupations and industries and assess the most appropriate method for data analysis. . Work performance was measured using the modified version of the HPQ conducted in workforce samples from the education and health workforce in Queensland, Australia (N = 30,870) during 2005 and 2006. Three approaches to data analysis of presenteeism measures were assessed using absolute performance, the ratio of own performance to others' performance, and the difference between others' and own performance. The best measure is judged by its sensitivity to changes in health indicators. . The measure that best correlated to health indicators was absolute presenteeism. For example, in the health sector, correlations between physical health status and absolute presenteeism were 4 to 5 times greater than the ratio or difference approaches, and in the education sector, these correlations were twice as large. Using this approach, the estimated cost of presenteeism in 2006 was $Aus8338 and $Aus8092 per worker per annum for the health and education sectors, respectively. . The HPQ is a valid measure of presenteeism. Transforming responses by perceived performance of peers is unnecessary as absolute presenteeism correlated best with health indicators. Absolute presenteeism was more insightful for ascertaining the cost of presenteeism.

  9. Results of the second Round Robin on opening-load measurement conducted by ASTM Task Group E24.04.04 on crack closure measurement and analysis

    NASA Technical Reports Server (NTRS)

    Phillips, E. P.

    1993-01-01

    A second experimental Round Robin on the measurement of the crack opening load in fatigue crack growth tests has been completed by the ASTM Task Group E24.04.04 on Crack Closure Measurement and Analysis. Fourteen laboratories participated in the testing of aluminum alloy compact tension specimens. Opening-load measurements were made at three crack lengths during constant Delta K, constant stress ratio tests by most of the participants. Four participants made opening-load measurements during threshold tests. All opening-load measurements were based on the analysis of specimens compliance behavior, where the displacement/strain was measured either at the crack mouth or the mid-height back face location. The Round Robin data were analyzed for opening load using two non-subjective analysis methods: the compliance offset and the correlation coefficient methods. The scatter in the opening load results was significantly reduced when some of the results were excluded from the analysis population based on an accept/reject criterion for raw data quality. The compliance offset and correlation coefficient opening load analysis methods produced similar results for data populations that had been screened to eliminate poor quality data.

  10. Effectiveness of Liquid-Liquid Extraction, Solid Phase Extraction, and Headspace Technique for Determination of Some Volatile Water-Soluble Compounds of Rose Aromatic Water

    PubMed Central

    2017-01-01

    Steam distillation is used to isolate scent of rose flowers. Rose aromatic water is commonly used in European cuisine and aromatherapy besides its use in cosmetic industry for its lovely scent. In this study, three different sampling techniques, liquid-liquid extraction (LLE), headspace technique (HS), and solid phase extraction (SPE), were compared for the analysis of volatile water-soluble compounds in commercial rose aromatic water. Some volatile water-soluble compounds of rose aromatic water were also analyzed by gas chromatography mass spectrometry (GCMS). In any case, it was concluded that one of the solid phase extraction methods led to higher recoveries for 2-phenylethyl alcohol (PEA) in the rose aromatic water than the liquid-liquid extraction and headspace technique. Liquid-liquid extraction method provided higher recovery ratios for citronellol, nerol, and geraniol than others. Ideal linear correlation coefficient values were observed by GCMS for quantitative analysis of volatile compounds (r2 ≥ 0.999). Optimized methods showed acceptable repeatability (RSDs < 5%) and excellent recovery (>95%). For compounds such as α-pinene, linalool, β-caryophyllene, α-humulene, methyl eugenol, and eugenol, the best recovery values were obtained with LLE and SPE. PMID:28791049

  11. Quality of reconstruction of compressed off-axis digital holograms by frequency filtering and wavelets.

    PubMed

    Cheremkhin, Pavel A; Kurbatova, Ekaterina A

    2018-01-01

    Compression of digital holograms can significantly help with the storage of objects and data in 2D and 3D form, its transmission, and its reconstruction. Compression of standard images by methods based on wavelets allows high compression ratios (up to 20-50 times) with minimum losses of quality. In the case of digital holograms, application of wavelets directly does not allow high values of compression to be obtained. However, additional preprocessing and postprocessing can afford significant compression of holograms and the acceptable quality of reconstructed images. In this paper application of wavelet transforms for compression of off-axis digital holograms are considered. The combined technique based on zero- and twin-order elimination, wavelet compression of the amplitude and phase components of the obtained Fourier spectrum, and further additional compression of wavelet coefficients by thresholding and quantization is considered. Numerical experiments on reconstruction of images from the compressed holograms are performed. The comparative analysis of applicability of various wavelets and methods of additional compression of wavelet coefficients is performed. Optimum parameters of compression of holograms by the methods can be estimated. Sizes of holographic information were decreased up to 190 times.

  12. Calculating binding free energies of host-guest systems using the AMOEBA polarizable force field.

    PubMed

    Bell, David R; Qi, Rui; Jing, Zhifeng; Xiang, Jin Yu; Mejias, Christopher; Schnieders, Michael J; Ponder, Jay W; Ren, Pengyu

    2016-11-09

    Molecular recognition is of paramount interest in many applications. Here we investigate a series of host-guest systems previously used in the SAMPL4 blind challenge by using molecular simulations and the AMOEBA polarizable force field. The free energy results computed by Bennett's acceptance ratio (BAR) method using the AMOEBA polarizable force field ranked favorably among the entries submitted to the SAMPL4 host-guest competition [Muddana, et al., J. Comput.-Aided Mol. Des., 2014, 28, 305-317]. In this work we conduct an in-depth analysis of the AMOEBA force field host-guest binding thermodynamics by using both BAR and the orthogonal space random walk (OSRW) methods. The binding entropy-enthalpy contributions are analyzed for each host-guest system. For systems of inordinate binding entropy-enthalpy values, we further examine the hydrogen bonding patterns and configurational entropy contribution. The binding mechanism of this series of host-guest systems varies from ligand to ligand, driven by enthalpy and/or entropy changes. Convergence of BAR and OSRW binding free energy methods is discussed. Ultimately, this work illustrates the value of molecular modelling and advanced force fields for the exploration and interpretation of binding thermodynamics.

  13. Evaluating significance in linear mixed-effects models in R.

    PubMed

    Luke, Steven G

    2017-08-01

    Mixed-effects models are being used ever more frequently in the analysis of experimental data. However, in the lme4 package in R the standards for evaluating significance of fixed effects in these models (i.e., obtaining p-values) are somewhat vague. There are good reasons for this, but as researchers who are using these models are required in many cases to report p-values, some method for evaluating the significance of the model output is needed. This paper reports the results of simulations showing that the two most common methods for evaluating significance, using likelihood ratio tests and applying the z distribution to the Wald t values from the model output (t-as-z), are somewhat anti-conservative, especially for smaller sample sizes. Other methods for evaluating significance, including parametric bootstrapping and the Kenward-Roger and Satterthwaite approximations for degrees of freedom, were also evaluated. The results of these simulations suggest that Type 1 error rates are closest to .05 when models are fitted using REML and p-values are derived using the Kenward-Roger or Satterthwaite approximations, as these approximations both produced acceptable Type 1 error rates even for smaller samples.

  14. A validated RP-HPLC method for simultaneous determination of propranolol and valsartan in bulk drug and gel formulation

    PubMed Central

    Imam, Syed Sarim; Ahad, Abdul; Aqil, Mohammed; Sultana, Yasmin; Ali, Asgar

    2013-01-01

    Objective: A simple, precise, and stability indicating high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of propranolol hydrochloride and valsartan in pharmaceutical dosage form. Materials and Methods: The method involves the use of easily available inexpensive laboratory reagents. The separation was achieved on Hypersil ODS C-18 column (250*4.6 mm, i.d., 5 μm particle size) with isocratic flow with UV detector. The mobile phase at a flow rate of 1.0 mL/min consisted of acetonitrile, methanol, and 0.01 M disodium hydrogen phosphate (pH 3.5) in the ratio of 50:35:15 v/v. Results: A linear response was observed over the concentration range 5-50 μg/mL of propranolol and the concentration range 4-32 μg/mL of valsartan. Limit of detection and limit of quantitation for propranolol were 0.27 μg/mL and 0.85 μg/mL, and for valsartan were 0.45 μg/mL and 1.39 μg/mL, respectively. The method was successfully validated in accordance to ICH guidelines acceptance criteria for linearity, accuracy, precision, specificity, robustness. Conclusion: The analysis concluded that the method was selective for simultaneous estimation of propranolol and valsartan can be potentially used for the estimation of these drugs in combined dosage form. PMID:23559826

  15. Preschools Willimg to Integrate Children with Handicaps. Directory 1974.

    ERIC Educational Resources Information Center

    Gorelick, Molly C., Comp.; Brown, Patricia A., Comp.

    The directory provides information on 59 State licensed private nursery schools in Los Angeles County which have indicated a willingness to accept children with handicaps. Given in the listing for each school are name, phone, address, capacity enrollment, ratio of adults to children, total number of teaching staff, number of volunteers, number of…

  16. Manganese chloride tetrahydrate (CMC-001) enhanced liver MRI: evaluation of efficacy and safety in healthy volunteers.

    PubMed

    Albiin, Nils; Kartalis, Nikolaos; Bergquist, Annika; Sadigh, Bita; Brismar, Torkel B

    2012-10-01

    To evaluate the efficacy of three dose levels of the oral hepatobiliary manganese-based magnetic resonance imaging (MRI) contrast agent CMC-001, and assess its safety profile and patient acceptability. After ethics committee approval, 32 healthy volunteers (males/females: 18/14) were included. Liver MRI was performed before and 3 h after ingestion of 0.8, 0.4, and 0.2 g of CMC-001 on separate occasions. Liver-to-muscle signal intensity (SI) ratio from baseline to post-contrast and image quality was assessed. Adverse drug reactions/adverse events (ADRs/AEs) and clinico-laboratory tests were monitored. The increase in liver-to-muscle SI ratio was significantly higher after 0.8 g (0.696) compared to 0.4 g (0.458) and 0.2 g (0.223) (in all pair-wise comparisons, P < 0.0001). The overall image quality was superior after 0.8 g. ADRs/AEs were dose-related and predominantly of mild intensity. Liver MRI using 0.8 g CMC-001 has the highest efficacy and still acceptable ADRs and should therefore be preferred.

  17. Properties of bologna-type sausages with pork back-fat replaced with pork skin and amorphous cellulose.

    PubMed

    de Oliveira Faria, Miriam; Cipriano, Tayssa Martins; da Cruz, Adriano Gomes; Santos, Bibiana Alves Dos; Pollonio, Marise Aparecida Rodrigues; Campagnol, Paulo Cezar Bastianello

    2015-06-01

    Bologna-type sausages were produced with 50% of their pork back-fat content replaced with gels elaborated with different ratios of pork skin, water, and amorphous cellulose (1:1:0, 1:1:0.1, 1:1:0.2, 1:1:0.3, and 1:1:0.4). The impact of such replacement on the physico-chemical characteristics and the consumer sensory profiling was evaluated. The modified treatments had 42% less fat, 18% more protein, and 8% more moisture than the control group. Treatments with amorphous cellulose had a lower cooking loss and higher emulsion stability. High amorphous cellulose content (1:1:0.3 and 1:1:0.4) increased hardness, gumminess, and chewiness. The gel formulated with the ratio of 1:1:0.2 (pork skin: water: amorphous cellulose gel) provided a sensory sensation similar to that provided by fat and allowed products of good acceptance to be obtained. Therefore, a combination of pork skin and amorphous cellulose is useful in improving technological quality and producing healthier and sensory acceptable bologna-type sausages. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Implications of ICU triage decisions on patient mortality: a cost-effectiveness analysis

    PubMed Central

    2011-01-01

    Introduction Intensive care is generally regarded as expensive, and as a result beds are limited. This has raised serious questions about rationing when there are insufficient beds for all those referred. However, the evidence for the cost effectiveness of intensive care is weak and the work that does exist usually assumes that those who are not admitted do not survive, which is not always the case. Randomised studies of the effectiveness of intensive care are difficult to justify on ethical grounds; therefore, this observational study examined the cost effectiveness of ICU admission by comparing patients who were accepted into ICU after ICU triage to those who were not accepted, while attempting to adjust such comparison for confounding factors. Methods This multi-centre observational cohort study involved 11 hospitals in 7 EU countries and was designed to assess the cost effectiveness of admission to intensive care after ICU triage. A total of 7,659 consecutive patients referred to the intensive care unit (ICU) were divided into those accepted for admission and those not accepted. The two groups were compared in terms of cost and mortality using multilevel regression models to account for differences across centres, and after adjusting for age, Karnofsky score and indication for ICU admission. The analyses were also stratified by categories of Simplified Acute Physiology Score (SAPS) II predicted mortality (< 5%, 5% to 40% and >40%). Cost effectiveness was evaluated as cost per life saved and cost per life-year saved. Results Admission to ICU produced a relative reduction in mortality risk, expressed as odds ratio, of 0.70 (0.52 to 0.94) at 28 days. When stratified by predicted mortality, the odds ratio was 1.49 (0.79 to 2.81), 0.7 (0.51 to 0.97) and 0.55 (0.37 to 0.83) for <5%, 5% to 40% and >40% predicted mortality, respectively. Average cost per life saved for all patients was $103,771 (€82,358) and cost per life-year saved was $7,065 (€5,607). These figures decreased substantially for patients with predicted mortality higher than 40%, $60,046 (€47,656) and $4,088 (€3,244), respectively. Results were very similar when considering three-month mortality. Sensitivity analyses performed to assess the robustness of the results provided findings similar to the main analyses. Conclusions Not only does ICU appear to produce an improvement in survival, but the cost per life saved falls for patients with greater severity of illness. This suggests that intensive care is similarly cost effective to other therapies that are generally regarded as essential. PMID:21306645

  19. Randomized Clinical Trial of Cognitive Behavioral Therapy (CBT) versus Acceptance and Commitment Therapy (ACT) for Mixed Anxiety Disorders

    ERIC Educational Resources Information Center

    Arch, Joanna J.; Eifert, Georg H.; Davies, Carolyn; Vilardaga, Jennifer C. Plumb; Rose, Raphael D.; Craske, Michelle G.

    2012-01-01

    Objective: Randomized comparisons of acceptance-based treatments with traditional cognitive behavioral therapy (CBT) for anxiety disorders are lacking. To address this gap, we compared acceptance and commitment therapy (ACT) to CBT for heterogeneous anxiety disorders. Method: One hundred twenty-eight individuals (52% female, mean age = 38, 33%…

  20. Acceptance- versus Change-Based Pain Management: The Role of Psychological Acceptance

    ERIC Educational Resources Information Center

    Blacker, Kara J.; Herbert, James D.; Forman, Evan M.; Kounios, John

    2012-01-01

    This study compared two theoretically opposed strategies for acute pain management: an acceptance-based and a change-based approach. These two strategies were compared in a within-subjects design using the cold pressor test as an acute pain induction method. Participants completed a baseline pain tolerance assessment followed by one of the two…

  1. Information Technologies Pre-Service Teachers' Acceptance of Tablet PCs as an Innovative Learning Tool

    ERIC Educational Resources Information Center

    Cuhadar, Cem

    2014-01-01

    The current study is aimed to determine if Turkish IT pre-service teachers' acceptance of tablet PCs is within the framework of the Technology Acceptance Model. The research was patterned as a phenomenological study which is among the qualitative research methods. Participants were eight pre-service teachers studying in Trakya University, Faculty…

  2. Behavior guidance techniques in Pediatric Dentistry: attitudes of parents of children with disabilities and without disabilities.

    PubMed

    de Castro, Alessandra Maia; de Oliveira, Fabiana Sodré; de Paiva Novaes, Myrian Stella; Araújo Ferreira, Danielly Cunha

    2013-01-01

    This study compared the parental acceptance of pediatric behavior guidance techniques (BGT). Forty parents of children without disabilities (Group A) and another 40 parents of children with disabilities (Group B) were selected. Each BGT was explained by a single examiner and it was presented together with a photograph album. After that parents evaluated the acceptance in: totally unacceptable, somewhat acceptable, acceptable, and totally acceptable. Results indicated that in Group A, the BGT based on communicative guidance was accepted by most participants. In Group B, just one mother considered totally unacceptable the voice control method and other two, tell-show-do. For both groups, the general anesthesia was the less accepted BGT. There was statistically significant difference in acceptance for protective stabilization with a restrictive device in Group B. Children's parents with and without disabilities accepted behavioral guidance techniques, but basic techniques showed higher rates of acceptance than advanced techniques. ©2013 Special Care Dentistry Association and Wiley Periodicals, Inc.

  3. 'PhysioDirect' telephone assessment and advice services for physiotherapy: protocol for a pragmatic randomised controlled trial

    PubMed Central

    Salisbury, Chris; Foster, Nadine E; Bishop, Annette; Calnan, Michael; Coast, Jo; Hall, Jeanette; Hay, Elaine; Hollinghurst, Sandra; Hopper, Cherida; Grove, Sean; Kaur, Surinder; Montgomery, Alan

    2009-01-01

    Background Providing timely access to physiotherapy has long been a problem for the National Health Service in the United Kingdom. In an attempt to improve access some physiotherapy services have introduced a new treatment pathway known as PhysioDirect. Physiotherapists offer initial assessment and advice by telephone, supported by computerised algorithms, and patients are sent written self-management and exercise advice by post. They are invited for face-to-face treatment only when necessary. Although several such services have been developed, there is no robust evidence regarding clinical and cost-effectiveness, nor the acceptability of PhysioDirect. Methods/Design This protocol describes a multi-centre pragmatic individually randomised trial, with nested qualitative research. The aim is to determine the effectiveness, cost-effectiveness, and acceptability of PhysioDirect compared with usual models of physiotherapy based on patients going onto a waiting list and receiving face-to-face care. PhysioDirect services will be established in four areas in England. Adult patients in these areas with musculoskeletal problems who refer themselves or are referred by a primary care practitioner for physiotherapy will be invited to participate in the trial. About 1875 consenting patients will be randomised in a 2:1 ratio to PhysioDirect or usual care. Data about outcome measures will be collected at baseline and 6 weeks and 6 months after randomisation. The primary outcome is clinical improvement at 6 months; secondary outcomes include cost, waiting times, time lost from work and usual activities, patient satisfaction and preference. The impact of PhysioDirect on patients in different age-groups and with different conditions will also be examined. Incremental cost-effectiveness will be assessed in terms of quality adjusted life years in relation to cost. Qualitative methods will be used to explore factors associated with the success or failure of the service, the acceptability of PhysioDirect to patients and staff, and ways in which the service could be improved. Discussion It is still relatively unusual to evaluate new forms of service delivery using randomised controlled trials. By combining rigorous trial methods with economic analysis of cost-effectiveness and qualitative research this study will provide robust evidence to inform decisions about the widespread introduction of PhysioDirect services. Trial registration Current Controlled Trials ISRCTN55666618 PMID:19650913

  4. A mixed-methods pilot study of the acceptability and effectiveness of a brief meditation and mindfulness intervention for people with diabetes and coronary heart disease.

    PubMed

    Keyworth, Chris; Knopp, Jasmin; Roughley, Kate; Dickens, Chris; Bold, Stuart; Coventry, Peter

    2014-01-01

    Mindfulness-based interventions can successfully target negative perseverative cognitions such as worry and thought suppression, but their acceptability and effectiveness in people with long-term conditions is uncertain. We therefore pilot tested a six-week meditation and mindfulness intervention in people (n = 40) with diabetes mellitus and coronary heart disease. We used a sequential mixed-methods approach that measured change in worry and thought suppression and qualitatively explored acceptability, feasibility, and user experience with a focus group (n = 11) and in-depth interviews (n = 16). The intervention was highly acceptable, with 90% completing ≥5 sessions. Meditation and mindfulness skills led to improved sleep, greater relaxation, and more-accepting approaches to illness and illness experience. At the end of the six-week meditation course, worry, and thought suppression were significantly reduced. Positive impacts of mindfulness-based interventions on psychological health may relate to acquisition and development of meta-cognitive skills but this needs experimental confirmation.

  5. A Mixed-Methods Pilot Study of the Acceptability and Effectiveness of a Brief Meditation and Mindfulness Intervention for People with Diabetes and Coronary Heart Disease

    PubMed Central

    Keyworth, Chris; Knopp, Jasmin; Roughley, Kate; Dickens, Chris; Bold, Stuart; Coventry, Peter

    2014-01-01

    Mindfulness-based interventions can successfully target negative perseverative cognitions such as worry and thought suppression, but their acceptability and effectiveness in people with long-term conditions is uncertain. We therefore pilot tested a six-week meditation and mindfulness intervention in people (n = 40) with diabetes mellitus and coronary heart disease. We used a sequential mixed-methods approach that measured change in worry and thought suppression and qualitatively explored acceptability, feasibility, and user experience with a focus group (n = 11) and in-depth interviews (n = 16). The intervention was highly acceptable, with 90% completing ≥5 sessions. Meditation and mindfulness skills led to improved sleep, greater relaxation, and more-accepting approaches to illness and illness experience. At the end of the six-week meditation course, worry, and thought suppression were significantly reduced. Positive impacts of mindfulness-based interventions on psychological health may relate to acquisition and development of meta-cognitive skills but this needs experimental confirmation. PMID:24754440

  6. Using the Detectability Index to Predict P300 Speller Performance

    PubMed Central

    Mainsah, B.O.; Collins, L.M.; Throckmorton, C.S.

    2017-01-01

    Objective The P300 speller is a popular brain-computer interface (BCI) system that has been investigated as a potential communication alternative for individuals with severe neuromuscular limitations. To achieve acceptable accuracy levels for communication, the system requires repeated data measurements in a given signal condition to enhance the signal-to-noise ratio of elicited brain responses. These elicited brain responses, which are used as control signals, are embedded in noisy electroencephalography (EEG) data. The discriminability between target and non-target EEG responses defines a user’s performance with the system. A previous P300 speller model has been proposed to estimate system accuracy given a certain amount of data collection. However, the approach was limited to a static stopping algorithm, i.e. averaging over a fixed number of measurements, and the row-column paradigm. A generalized method that is also applicable to dynamic stopping algorithms and other stimulus paradigms is desirable. Approach We developed a new probabilistic model-based approach to predicting BCI performance, where performance functions can be derived analytically or via Monte Carlo methods. Within this framework, we introduce a new model for the P300 speller with the Bayesian dynamic stopping (DS) algorithm, by simplifying a multi-hypothesis to a binary hypothesis problem using the likelihood ratio test. Under a normality assumption, the performance functions for the Bayesian algorithm can be parameterized with the detectability index, a measure which quantifies the discriminability between target and non-target EEG responses. Main results Simulations with synthetic and empirical data provided initial verification of the proposed method of estimating performance with Bayesian DS using the detectability index. Analysis of results from previous online studies validated the proposed method. Significance The proposed method could serve as a useful tool to initially asses BCI performance without extensive online testing, in order to estimate the amount of data required to achieve a desired accuracy level. PMID:27705956

  7. Using the detectability index to predict P300 speller performance

    NASA Astrophysics Data System (ADS)

    Mainsah, B. O.; Collins, L. M.; Throckmorton, C. S.

    2016-12-01

    Objective. The P300 speller is a popular brain-computer interface (BCI) system that has been investigated as a potential communication alternative for individuals with severe neuromuscular limitations. To achieve acceptable accuracy levels for communication, the system requires repeated data measurements in a given signal condition to enhance the signal-to-noise ratio of elicited brain responses. These elicited brain responses, which are used as control signals, are embedded in noisy electroencephalography (EEG) data. The discriminability between target and non-target EEG responses defines a user’s performance with the system. A previous P300 speller model has been proposed to estimate system accuracy given a certain amount of data collection. However, the approach was limited to a static stopping algorithm, i.e. averaging over a fixed number of measurements, and the row-column paradigm. A generalized method that is also applicable to dynamic stopping (DS) algorithms and other stimulus paradigms is desirable. Approach. We developed a new probabilistic model-based approach to predicting BCI performance, where performance functions can be derived analytically or via Monte Carlo methods. Within this framework, we introduce a new model for the P300 speller with the Bayesian DS algorithm, by simplifying a multi-hypothesis to a binary hypothesis problem using the likelihood ratio test. Under a normality assumption, the performance functions for the Bayesian algorithm can be parameterized with the detectability index, a measure which quantifies the discriminability between target and non-target EEG responses. Main results. Simulations with synthetic and empirical data provided initial verification of the proposed method of estimating performance with Bayesian DS using the detectability index. Analysis of results from previous online studies validated the proposed method. Significance. The proposed method could serve as a useful tool to initially assess BCI performance without extensive online testing, in order to estimate the amount of data required to achieve a desired accuracy level.

  8. In vitro starch digestion and cake quality: impact of the ratio of soluble and insoluble dietary fiber.

    PubMed

    Oh, Im Kyung; Bae, In Young; Lee, Hyeon Gyu

    2014-02-01

    The influence of the ratio of soluble dietary fiber (SDF) and insoluble dietary fiber (IDF) on the in vitro starch digestion, predicted glycemic index (pGI), and the physicochemical properties of fiber-enriched cakes were evaluated. The hydration and pasting properties were affected by the ratio of SDF and IDF. According to the increase of IDF ratio (SDF ratio reduction) in 3 g fiber-enriched cakes, slowly digestible starch (SDS) contents increased, while the rapidly digestible starch (RDS) contents decreased. The pGI values were significantly different with control in 3 g fiber-enriched cake containing more than 50% IDF contents (p<0.05). But the pGI values of 6g fiber-enriched cake samples were not significantly different by SDF and IDF ratio. With the exception of the SDF 100% cake, volume index, hardness, and color values of the fiber-enriched cakes increased according to reductions in the SDF ratio. The cakes containing 3 g of total dietary fiber (the same ratio of SDF and IDF) per serving were shown to have low pGI and acceptable quality attributes. Specially, total dietary fiber amount and IDF ratio are more effective than SDF ratio to lower the pGI value. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Key acceptability attributes of orodispersible films.

    PubMed

    Scarpa, Mariagiovanna; Paudel, Amrit; Kloprogge, Frank; Hsiao, Wen Kai; Bresciani, Massimo; Gaisford, Simon; Orlu, Mine

    2018-04-01

    The features rendering orodispersible films (ODFs) patient-centric formulations are widely discussed in the scientific literature. However there is a lack of research studies exploring ODF characteristics with a potential impact on end-user acceptability. The aim of this study was to identify the key ODF characteristics affecting end-user acceptability by developing in vitro test methods for the prediction of ODFs acceptability and correlate these formulation characteristics with the data obtained from a human panel study. Four drug-free single-polymer films were prepared by solvent casting. Solutions of poly(vinyl) alcohol (PVOH) 39 KDa (P1), PVOH 197 KDa (P2), carboxymethylcellulose (CMC) 395 KDa (C1), and CMC 725 KDa (C2) were prepared. Texture analysis and Dynamic Mechanical Analysis (DMA) were used to assess film tack. Petri dish and drop methods were used to assess disintegration time. A human panel of 24 healthy young adults was employed to identify end-user acceptability criteria of the four study film samples. Texture analysis data of ODF tack were not found to be in agreement with the in vivo perceived stickiness in the mouth. However, measurement of the area under the adhesive force curve obtained by DMA correlated with in vivo perceived stickiness data for all samples. The disintegration times obtained by drop method were more comparable to human panel data than the petri dish method. Hence DMA and drop methods proved to be promising methodologies for the prediction of the end-user acceptability. The type and molecular weight of the film-forming polymer had a strong influence on stickiness perception, whereas only polymeric molecular weight influenced perceived disintegration time. The human panel study showed that Participant Reported Outcomes (PROs) for the perceived stickiness in the mouth and disintegration time of test films received significantly different scores between samples, and thus were identified as the key attributes with the potential to affect the end-user acceptability. ODF stickiness and disintegration time should therefore be evaluated at an early stage of the drug product design. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. The regulatory acceptance of alternatives in the European Union.

    PubMed

    Warbrick, E Vicky; Evans, Peter F

    2004-06-01

    Recently, progress has been made toward the regulatory acceptance of replacements in the European Union (EU), particularly with the introduction of in vitro methods for the prediction of skin corrosivity, dermal penetration, phototoxicity and embryotoxicity. In vitro genotoxicity tests are well established, and testing for this endpoint can be completed without animals, provided that clear negative outcomes are obtained. Tiered approaches including in vitro tests can also be used to address skin and eye irritation endpoints. Reductions and/or refinements in animal use are being achieved following the replacement of the oral LD50 test with alternative methods and the adoption of reduced test packages for materials, such as closed-system intermediates and certain polymers. Furthermore, the use of a "read-across" approach has reduced animal testing. Substantial gains in refinement will also be made with the recent acceptance of the local lymph node assay for skin sensitisation and the development of an acute inhalation toxicity method that avoids lethality as the endpoint. For the future, under the proposed EU Registration, Evaluation and Authorisation of Chemicals (REACH) scheme, it is envisaged that, where suitable in vitro methods exist, these should be used to support registration of substances produced at up to ten tonnes per annum. This proposal can only accelerate the further development, validation and regulatory acceptance of such alternative methods.

  11. Local tolerance testing under REACH: Accepted non-animal methods are not on equal footing with animal tests.

    PubMed

    Sauer, Ursula G; Hill, Erin H; Curren, Rodger D; Raabe, Hans A; Kolle, Susanne N; Teubner, Wera; Mehling, Annette; Landsiedel, Robert

    2016-07-01

    In general, no single non-animal method can cover the complexity of any given animal test. Therefore, fixed sets of in vitro (and in chemico) methods have been combined into testing strategies for skin and eye irritation and skin sensitisation testing, with pre-defined prediction models for substance classification. Many of these methods have been adopted as OECD test guidelines. Various testing strategies have been successfully validated in extensive in-house and inter-laboratory studies, but they have not yet received formal acceptance for substance classification. Therefore, under the European REACH Regulation, data from testing strategies can, in general, only be used in so-called weight-of-evidence approaches. While animal testing data generated under the specific REACH information requirements are per se sufficient, the sufficiency of weight-of-evidence approaches can be questioned under the REACH system, and further animal testing can be required. This constitutes an imbalance between the regulatory acceptance of data from approved non-animal methods and animal tests that is not justified on scientific grounds. To ensure that testing strategies for local tolerance testing truly serve to replace animal testing for the REACH registration 2018 deadline (when the majority of existing chemicals have to be registered), clarity on their regulatory acceptance as complete replacements is urgently required. 2016 FRAME.

  12. The use of cost per life year gained as a measurement of cost-effectiveness in Spain: a systematic review of recent publications.

    PubMed

    Rodríguez Barrios, José Manuel; Pérez Alcántara, Ferran; Crespo Palomo, Carlos; González García, Paloma; Antón De Las Heras, Enrique; Brosa Riestra, Max

    2012-12-01

    The objective of this study was to evaluate the methodological characteristics of cost-effectiveness evaluations carried out in Spain, since 1990, which include LYG as an outcome to measure the incremental cost-effectiveness ratio. A systematic review of published studies was conducted describing their characteristics and methodological quality. We analyse the cost per LYG results in relation with a commonly accepted Spanish cost-effectiveness threshold and the possible relation with the cost per quality adjusted life year (QALY) gained when they both were calculated for the same economic evaluation. A total of 62 economic evaluations fulfilled the selection criteria, 24 of them including the cost per QALY gained result as well. The methodological quality of the studies was good (55%) or very good (26%). A total of 124 cost per LYG results were obtained with a mean ratio of 49,529 and a median of 11,490 (standard deviation of 183,080). Since 2003, a commonly accepted Spanish threshold has been referenced by 66% of studies. A significant correlation was found between the cost per LYG and cost per QALY gained results (0.89 Spearman-Rho, 0.91 Pearson). There is an increasing interest for economic health care evaluations in Spain, and the quality of the studies is also improving. Although a commonly accepted threshold exists, further information is needed for decision-making as well as to identify the relationship between the costs per LYG and per QALY gained.

  13. Dual Energy Method for Breast Imaging: A Simulation Study.

    PubMed

    Koukou, V; Martini, N; Michail, C; Sotiropoulou, P; Fountzoula, C; Kalyvas, N; Kandarakis, I; Nikiforidis, G; Fountos, G

    2015-01-01

    Dual energy methods can suppress the contrast between adipose and glandular tissues in the breast and therefore enhance the visibility of calcifications. In this study, a dual energy method based on analytical modeling was developed for the detection of minimum microcalcification thickness. To this aim, a modified radiographic X-ray unit was considered, in order to overcome the limited kVp range of mammographic units used in previous DE studies, combined with a high resolution CMOS sensor (pixel size of 22.5 μm) for improved resolution. Various filter materials were examined based on their K-absorption edge. Hydroxyapatite (HAp) was used to simulate microcalcifications. The contrast to noise ratio (CNR tc ) of the subtracted images was calculated for both monoenergetic and polyenergetic X-ray beams. The optimum monoenergetic pair was 23/58 keV for the low and high energy, respectively, resulting in a minimum detectable microcalcification thickness of 100 μm. In the polyenergetic X-ray study, the optimal spectral combination was 40/70 kVp filtered with 100 μm cadmium and 1000 μm copper, respectively. In this case, the minimum detectable microcalcification thickness was 150 μm. The proposed dual energy method provides improved microcalcification detectability in breast imaging with mean glandular dose values within acceptable levels.

  14. Dual Energy Method for Breast Imaging: A Simulation Study

    PubMed Central

    2015-01-01

    Dual energy methods can suppress the contrast between adipose and glandular tissues in the breast and therefore enhance the visibility of calcifications. In this study, a dual energy method based on analytical modeling was developed for the detection of minimum microcalcification thickness. To this aim, a modified radiographic X-ray unit was considered, in order to overcome the limited kVp range of mammographic units used in previous DE studies, combined with a high resolution CMOS sensor (pixel size of 22.5 μm) for improved resolution. Various filter materials were examined based on their K-absorption edge. Hydroxyapatite (HAp) was used to simulate microcalcifications. The contrast to noise ratio (CNRtc) of the subtracted images was calculated for both monoenergetic and polyenergetic X-ray beams. The optimum monoenergetic pair was 23/58 keV for the low and high energy, respectively, resulting in a minimum detectable microcalcification thickness of 100 μm. In the polyenergetic X-ray study, the optimal spectral combination was 40/70 kVp filtered with 100 μm cadmium and 1000 μm copper, respectively. In this case, the minimum detectable microcalcification thickness was 150 μm. The proposed dual energy method provides improved microcalcification detectability in breast imaging with mean glandular dose values within acceptable levels. PMID:26246848

  15. Controlled source electrical methods for deep exploration

    NASA Astrophysics Data System (ADS)

    Ward, Stanley H.

    1983-07-01

    Application of controlled source electrical methods (CSEM) is impeded by natural field, electrification, geological, cultural, and topographic noise. Lateral resolution of parameters of adjacent steeply dipping bodies and vertical resolution of parameters of adjacent beds in a flatly dipping sequence are concerns with any CSEM method. Current channeling into a localized good conductor from a surrounding, overlying, or underlying conductor poses problems for the interpreter. A summary of the results of several recent experiments with CSEM techniques illustrates that with care and difficulty they can be used to depths on the order of 20 km. If measurements are made on a relatively uniform resistive surface, as can be found in glaciated Precambrian terranes, then either a grounded bipole or a loop source is acceptable. Most of the recent CSEM experiments were made over resistive Precambrian rocks and all were directed toward detecting a conductive layer near 20 km depth. For exploration beyond this depth, however, the MT/AMT method would seem to be preferred. The rationale behind this conclusion is largely contained in consideration of the ratio of signal to natural field noise. Where thick irregular surficial overburden of low resistivity occurs, two- and three-dimensional modeling is necessary to stripp off the effects of the shallow layers. This may not be possible for CSEM and then MT/AMT becomes the only alternative.

  16. Determination of moclobemide in human plasma by high-performance liquid chromatography with spectrophotometric detection.

    PubMed

    Amini, Hossein; Shahmir, Badri; Ahmadiani, Abolhassan

    2004-08-05

    A simple and sensitive high-performance liquid chromatographic (HPLC) method with spectrophotometric detection was developed for the determination of moclobemide in human plasma. Plasma samples were extracted under basic conditions with dichloromethane followed by back-extraction into diluted phosphoric acid. Isocratic separation was employed on an ODS column (250 mm x 4.6 mm, 5 microm) at room temperature. The mobile phase consisted of 5 mM NaH2PO4-acetonitrile-triethylamine (1000:350:10 (v/v/v), pH 3.4). Analyses were run at a flow-rate of 1.0 ml/min and ultraviolet (UV) detection was carried out at 240 nm. The method was specific and sensitive with a quantification limit of 15.6 ng/ml and a detection limit of 5 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery was about 98.2%, while the intra- and inter-day coefficient of variation and percent error values of the assay method were all at acceptable levels. Linearity was assessed in the range of 15.6-2000 ng/ml in plasma with a correlation coefficient of greater than 0.999. This method has been used to analyze several hundred human plasma samples for bioavailibility studies.

  17. Differences in perception of dysentery and enteric fever and willingness to receive vaccines among rural residents in China.

    PubMed

    Chen, Xinguang; Stanton, Bonita; Wang, Xuanyi; Nyamette, Andrew; Pach, Alfred; Kaljee, Linda; Pack, Robert; von Seidlein, Lorenz; Clemens, John; Gong, Youlong; Mao, Rong

    2006-01-30

    Enteric diseases including dysentery and enteric fever remain significant public health problems in China. While vaccines offer great potential in controlling these diseases, greater understanding of factors influencing acceptance of vaccines is needed to create effective enteric disease control programs in rural China. Cross-sectional quantitative study with randomly sampled households from two sites in China, one experiencing high rates of shigellosis (Zengding) and the other of typhoid/paratyphoid (Lingchuan). Sociobehavioral survey data were collected through face-to-face interviews from 501 respondents (56% female) in Zhengding regarding dysentery and 624 in Lingchuan (51% female) regarding enteric fever. Vaccine acceptability was measured by expressed need for vaccination and willingness to pay. Comparative and associative analyses were conducted to assess disease perception, vaccination service satisfaction, likelihood of improvements in water and sanitation, and vaccine acceptability. Nearly all respondents in Lingchuan considered enteric fever to be prevalent in the community, while only one half of the respondents in Zhengding considered dysentery to be problematic (p < 0.01). Nevertheless, more respondents in Zhengding were fearful that a household member would acquire dysentery than were Lingchuan respondents worried that a household member would acquire enteric fever (p < 0.01). Perceived vulnerability of specific subgroups (odds ratios ranging from 1.6 to 8.1), knowing someone who died of the disease (odds ratio reached infinity) and satisfaction with past vaccination services (odds ratios reached infinity) were consistently associated with perceived need for vaccines of target populations of all age groups while the association between perception of sanitary improvement and vaccine need was limited. Perceived need for a vaccine was associated with willingness to pay for the vaccine. Perceptions of enhanced vulnerability of specific subgroups to a disease and satisfactory experiences with vaccination services may increase the perceived need for a vaccine, leading to increased willingness to pay for vaccine. Vaccines are not perceived as important for the elderly.

  18. Correlation of radiologists' image quality perception with quantitative assessment parameters: just-noticeable difference vs. peak signal-to-noise ratios

    NASA Astrophysics Data System (ADS)

    Siddiqui, Khan M.; Siegel, Eliot L.; Reiner, Bruce I.; Johnson, Jeffrey P.

    2005-04-01

    The authors identify a fundamental disconnect between the ways in which industry and radiologists assess and even discuss product performance. What is needed is a quantitative methodology that can assess both subjective image quality and observer task performance. In this study, we propose and evaluate the use of a visual discrimination model (VDM) that assesses just-noticeable differences (JNDs) to serve this purpose. The study compares radiologists' subjective perceptions of image quality of computer tomography (CT) and computed radiography (CR) images with quantitative measures of peak signal-to-noise ratio (PSNR) and JNDs as measured by a VDM. The study included 4 CT and 6 CR studies with compression ratios ranging from lossless to 90:1 (total of 80 sets of images were generated [n = 1,200]). Eleven radiologists reviewed the images and rated them in terms of overall quality and readability and identified images not acceptable for interpretation. Normalized reader scores were correlated with compression, objective PSNR, and mean JND values. Results indicated a significantly higher correlation between observer performance and JND values than with PSNR methods. These results support the use of the VDM as a metric not only for the threshold discriminations for which it was calibrated, but also as a general image quality metric. This VDM is a highly promising, reproducible, and reliable adjunct or even alternative to human observer studies for research or to establish clinical guidelines for image compression, dose reductions, and evaluation of various display technologies.

  19. Chronic Use of Theophylline and Mortality in Chronic Obstructive Pulmonary Disease: A Meta-analysis.

    PubMed

    Horita, Nobuyuki; Miyazawa, Naoki; Kojima, Ryota; Inoue, Miyo; Ishigatsubo, Yoshiaki; Kaneko, Takeshi

    2016-05-01

    Theophylline has been shown to improve respiratory function and oxygenation in patients with chronic obstruction pulmonary disease (COPD). However, the impact of theophylline on mortality in COPD patients has not been not sufficiently evaluated. Two investigators independently searched for eligible articles in 4 databases. The eligibility criterion for this meta-analysis was an original research article that provided a hazard ratio for theophylline for all-cause mortality of COPD patients. Both randomized controlled trials and observational studies were accepted. After we confirmed no substantial heterogeneity (I(2)<50%), the fixed-model method with generic inverse variance was used for meta-analysis to estimate the pooled hazard ratio. We screened 364 potentially eligible articles. Of the 364 articles, 259 were excluded on the basis of title and abstract, and 99 were excluded after examination of the full text. Our final analysis included 6 observational studies and no randomized controlled trials. One study reported 2 cohorts. The number of patients in each cohort ranged from 47 to 46,403. Heterogeneity (I(2)=42%, P=.11) and publication bias (Begg's test r=0.21, P=.662) were not substantial. Fixed-model meta-analysis yielded a pooled hazard ratio for theophylline for all-cause death of 1.07 (95% confidence interval: 1.02-1.13, P=.003). This meta-analysis of 7 observational cohorts suggests that theophylline slightly increases all-cause death in COPD patients. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  20. 40 CFR 91.313 - Analyzers required.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  1. 40 CFR 90.313 - Analyzers required.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  2. 40 CFR 90.313 - Analyzers required.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  3. 40 CFR 91.313 - Analyzers required.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  4. 40 CFR 91.313 - Analyzers required.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  5. 40 CFR 91.313 - Analyzers required.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  6. 40 CFR 90.313 - Analyzers required.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  7. 40 CFR 90.313 - Analyzers required.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  8. Efficient Kill-Save Ratios Ease Up the Cognitive Demands on Counterintuitive Moral Utilitarianism.

    PubMed

    Trémolière, Bastien; Bonnefon, Jean-François

    2014-07-01

    The dual-process model of moral judgment postulates that utilitarian responses to moral dilemmas (e.g., accepting to kill one to save five) are demanding of cognitive resources. Here we show that utilitarian responses can become effortless, even when they involve to kill someone, as long as the kill-save ratio is efficient (e.g., 1 is killed to save 500). In Experiment 1, participants responded to moral dilemmas featuring different kill-save ratios under high or low cognitive load. In Experiments 2 and 3, participants responded at their own pace or under time pressure. Efficient kill-save ratios promoted utilitarian responding and neutered the effect of load or time pressure. We discuss whether this effect is more easily explained by a parallel-activation model or by a default-interventionist model. © 2014 by the Society for Personality and Social Psychology, Inc.

  9. (1 + 1) resonant enhanced multiphoton ionization via the A2Sigma(+) state of NO - Ionic rotational branching ratios and their intensity dependence

    NASA Technical Reports Server (NTRS)

    Rudolph, H.; Mckoy, V.; Dixit, S. N.; Huo, W. M.

    1988-01-01

    Rotational branching ratios resulting from the (1 + 1) resonant enhanced multiphoton ionization spectroscopy of NO via the 0-0 transition of the A-X band for the four possible branches that can be assigned as R(21.5) are explored using calculation performed in the frozen-core approximation at the Hartree-Fock level. The four different branches, of which three are distinctly different in the perturbative limit, have rather different branching ratios. The mixed R12 + Q22(21.5) branch, which is not intense and has the lowest transition energy, appears to give the best agreement with experimental branching ratio for parallel detection. The agreement is less satisfactory for perpendicular detection. Neither the effect of finite-acceptance angle of the photoelectron detector nor high intensities can explain the discrepancy.

  10. The process of accepting breast cancer among Chinese women: A grounded theory study.

    PubMed

    Chen, Shuang-Qin; Liu, Jun-E; Li, Zhi; Su, Ya-Li

    2017-06-01

    To describe the process by which Chinese women accept living with breast cancer. Individual interviews were conducted with 18 Chinese women who completed breast cancer treatment. Data were collected from September 2014 to January 2015 at a large tertiary teaching hospital in Beijing, China. In this grounded theory study, data were analyzed using constant comparative and coding analysis methods. In order to explain the process of accepting having breast cancer among women in China through the grounded theory study, a model that includes 5 axial categories was developed. Cognitive reconstruction emerged as the core category. The extent to which the women with breast cancer accepted having the disease was found to increase with the treatment stage and as their treatment stage progressed with time. The accepting process included five stages: non-acceptance, passive acceptance, willingness to accept, behavioral acceptance, and transcendence of acceptance. Our study using grounded theory study develops a model describing the process by which women accept having breast cancer. The model provides some intervention opportunities at every point of the process. Copyright © 2017. Published by Elsevier Ltd.

  11. Collaborative derivation of reference intervals for major clinical laboratory tests in Japan.

    PubMed

    Ichihara, Kiyoshi; Yomamoto, Yoshikazu; Hotta, Taeko; Hosogaya, Shigemi; Miyachi, Hayato; Itoh, Yoshihisa; Ishibashi, Midori; Kang, Dongchon

    2016-05-01

    Three multicentre studies of reference intervals were conducted recently in Japan. The Committee on Common Reference Intervals of the Japan Society of Clinical Chemistry sought to establish common reference intervals for 40 laboratory tests which were measured in common in the three studies and regarded as well harmonized in Japan. The study protocols were comparable with recruitment mostly from hospital workers with body mass index ≤28 and no medications. Age and sex distributions were made equal to obtain a final data size of 6345 individuals. Between-subgroup differences were expressed as the SD ratio (between-subgroup SD divided by SD representing the reference interval). Between-study differences were all within acceptable levels, and thus the three datasets were merged. By adopting SD ratio ≥0.50 as a guide, sex-specific reference intervals were necessary for 12 assays. Age-specific reference intervals for females partitioned at age 45 were required for five analytes. The reference intervals derived by the parametric method resulted in appreciable narrowing of the ranges by applying the latent abnormal values exclusion method in 10 items which were closely associated with prevalent disorders among healthy individuals. Sex- and age-related profiles of reference values, derived from individuals with no abnormal results in major tests, showed peculiar patterns specific to each analyte. Common reference intervals for nationwide use were developed for 40 major tests, based on three multicentre studies by advanced statistical methods. Sex- and age-related profiles of reference values are of great relevance not only for interpreting test results, but for applying clinical decision limits specified in various clinical guidelines. © The Author(s) 2015.

  12. Azimuth selection for sea level measurements using geodetic GPS receivers

    NASA Astrophysics Data System (ADS)

    Wang, Xiaolei; Zhang, Qin; Zhang, Shuangcheng

    2018-03-01

    Based on analysis of Global Positioning System (GPS) multipath signals recorded by a geodetic GPS receiver, GPS Reflectometry (GPS-R) has demonstrated unique advantages in relation to sea level monitoring. Founded on multipath reflectometry theory, sea level changes can be measured by GPS-R through spectral analysis of recorded signal-to-noise ratio data. However, prior to estimating multipath parameters, it is necessary to define azimuth and elevation angle mask to ensure the reflecting zones are on water. Here, a method is presented to address azimuth selection, a topic currently under active development in the field of GPS-R. Data from three test sites: the Kachemak Bay GPS site PBAY in Alaska (USA), Friday Harbor GPS site SC02 in the San Juan Islands (USA), and Brest Harbor GPS site BRST in Brest (France) are analyzed. These sites are located in different multipath environments, from a rural coastal area to a busy harbor, and they experience different tidal ranges. Estimates by the GPS tide gauges at azimuths selected by the presented method are compared with measurements from physical tide gauges and acceptable correspondence found for all three sites.

  13. Dynamic measurements of gear tooth friction and load

    NASA Technical Reports Server (NTRS)

    Rebbechi, Brian; Oswald, Fred B.; Townsend, Dennis P.

    1991-01-01

    As part of a program to study fundamental mechanisms of gear noise, static and dynamic gear tooth strain measurements were made on the NASA gear-noise rig. Tooth-fillet strains from low-contact ratio-spur gears were recorded for 28 operating conditions. A method is introduced whereby strain gage measurements taken from both the tension and compression sides of a gear tooth can be transformed into the normal and frictional loads on the tooth. This technique was applied to both the static and dynamic strain data. The static case results showed close agreement with expected results. For the dynamic case, the normal-force computation produced very good results, but the friction results, although promising, were not as accurate. Tooth sliding friction strongly affected the signal from the strain gage on the tensionside of the tooth. The compression gage was affected by friction to a much lesser degree. The potential of the method to measure friction force was demonstrated, but further refinement will be required before this technique can be used to measure friction forces dynamically with an acceptable degree of accuracy.

  14. Acceptance of illness and satisfaction with life among malaria patients in rivers state, Nigeria

    PubMed Central

    2014-01-01

    Background Health condition is one of the basic factors affecting satisfaction with life, and the level of illness acceptance. The purpose of the study was to analyse the level of illness acceptance, the level of satisfaction with life among malaria patients, and the level of trust placed in the physician and the nurse. Methods The study employs the method of diagnostic survey based on standardised AIS and SWLS scales, as well as Anderson and Dedrick’s PPTS and PNTS scales. Results The average AIS level was 12 points, while the average level of SwL at the SWLS scale was 16.5 points. The average level of trust in the physician and the nurse amounted to 50.6 points and 51.4 points, respectively. The correlation between the level of illness acceptance and self-evaluated satisfaction with life was statistically significant, with R = 0.56. The marital status influenced the level of illness acceptance with p < 0.05 and the level of satisfaction with life with p < 0.05. The employment status affected the level of satisfaction with life with p < 0.05 and the level of illness acceptance with p < 0.05. Conclusions The majority of malaria patients did not accept their illness, while the level of satisfaction with life was low. The majority of respondents trusted their physician and nurse. There is a statistically significant correlation between the level of illness acceptance and the self-evaluated satisfaction with life. The marital status had a statistically significant effect on the acceptance of illness and the satisfaction with life. The individuals who had a job demonstrated higher levels of quality of life and illness acceptance. PMID:24885562

  15. Factors associated with interest in novel interfaces for upper limb prosthesis control

    PubMed Central

    Engdahl, Susannah M.; Chestek, Cynthia A.; Kelly, Brian; Davis, Alicia

    2017-01-01

    Background Surgically invasive interfaces for upper limb prosthesis control may allow users to operate advanced, multi-articulated devices. Given the potential medical risks of these invasive interfaces, it is important to understand what factors influence an individual’s decision to try one. Methods We conducted an anonymous online survey of individuals with upper limb loss. A total of 232 participants provided personal information (such as age, amputation level, etc.) and rated how likely they would be to try noninvasive (myoelectric) and invasive (targeted muscle reinnervation, peripheral nerve interfaces, cortical interfaces) interfaces for prosthesis control. Bivariate relationships between interest in each interface and 16 personal descriptors were examined. Significant variables from the bivariate analyses were then entered into multiple logistic regression models to predict interest in each interface. Results While many of the bivariate relationships were significant, only a few variables remained significant in the regression models. The regression models showed that participants were more likely to be interested in all interfaces if they had unilateral limb loss (p ≤ 0.001, odds ratio ≥ 2.799). Participants were more likely to be interested in the three invasive interfaces if they were younger (p < 0.001, odds ratio ≤ 0.959) and had acquired limb loss (p ≤ 0.012, odds ratio ≥ 3.287). Participants who used a myoelectric device were more likely to be interested in myoelectric control than those who did not (p = 0.003, odds ratio = 24.958). Conclusions Novel prosthesis control interfaces may be accepted most readily by individuals who are young, have unilateral limb loss, and/or have acquired limb loss However, this analysis did not include all possible factors that may have influenced participant’s opinions on the interfaces, so additional exploration is warranted. PMID:28767716

  16. Differentiation between malignant and non-malignant pleural effusion using cancer ratio and other new parameters.

    PubMed

    Korczynski, Piotr; Mierzejewski, Michal; Krenke, Rafal; Safianowska, Aleksandra; Light, Richard W

    2018-06-05

    Introduction In contrast to tuberculous pleurisy (TP), no accurate and commonly accepted biochemical marker of malignant pleural effusion (MPE) has been established. Objectives We aimed to: 1) evaluate the ability of previously reported cancer ratio (CR) to discriminate MPEs and non-MPEs, 2) test whether age may have additional value in differentiating MPEs and non MPEs, and if so, 3) to combine LDH and age with other TP biomarkers in search of an index useful in the identification of MPE. Patients and methods A retrospective analysis of data from 140 patients with malignant (n=74), tuberculous (n=37) and parapneumonic (n=29) pleural effusions was performed. The diagnostic performance of a test to discriminate between MPEs and non-MPEs was evaluated using Receiver Operating Characteristic. Results Three ratios showed the largest AUC: serum LDH/pleural fluid soluble Fas ligand, age/pleural fluid ADA and serum LDH/pleural fluid IL-18 and were characterized by a high sensitivity (95, 93.2, 92.9% respectively) and fair specificity (64.8, 71.2, 58.5% respectively) in discrimination MPE from non-MPEs. AUC for CR was lower than for aforementioned values and showed 94.6% sensitivity and 68.2% specificity. Conclusions Our study showed a lower specificity of CR in discriminating MPEs and non-MPEs than previously reported. We demonstrated that combinations of serum LDH with other pleural fluid biomarkers of TP have a similar diagnostic performance. We also found that age might be an important factor differentiating between MPEs and non-MPEs and propose a new age/pleural fluid ADA ratio which has a discriminative potential similar to that of CR.

  17. Preliminary Criteria for Global Flares in Childhood-Onset Systemic Lupus Erythematosus

    PubMed Central

    Brunner, Hermine I.; Mina, Rina; Pilkington, Clarissa; Beresford, Michael W.; Reiff, Andreas; Levy, Deborah M.; Tucker, Lori B.; Eberhard, B. Anne; Ravelli, Angelo; Schanberg, Laura E.; Saad-Magalhaes, Claudia; Higgins, Gloria C.; Onel, Karen; Singer, Nora G.; von Scheven, Emily; Itert, Lukasz; Klein-Gitelman, Marisa S.; Punaro, Marilynn; Ying, Jun; Giannini, Edward H.

    2011-01-01

    Objectives To develop widely acceptable preliminary criteria of global flare for childhood-onset SLE (cSLE). Methods Pediatric rheumatologists (n=138) rated a total of 358 unique patient profiles (PP) with information about the cSLE flare descriptors (cSLE-FD) from two consecutive visits: patient global assessment of well-being, physician global assessment of disease activity (MD-global), health-related quality of life, anti-dsDNA antibodies, disease activity index score, protein/creatinine (P/C) ratio, complement levels and ESR. Based on 2996 rater responses about the course of cSLE (baseline vs. follow-up) the accuracy (sensitivity, specificity, area under the receiver operating characteristic curve) of candidate flare criteria was assessed. An international consensus conference was held to rank these candidate flare criteria as per the ACR-recommendations for the development and validation of criteria sets. Results The highest ranked candidate criteria considered absolute changes (Δ) of the SLEDAI or BILAG, MD-global, P/C ratio, and ESR; Flare scores can be calculated [0.5 × ΔSLEDAI + 0.45 × ΔP/C ratio + 0.5 × ΔMD-global + 0.02 × ΔESR], where values ≥ 1.04 are reflective of a flare. Similarly, BILAG-based flare scores [0.4 × ΔBILAG + 0.65 × ΔP/C ratio + 0.5 × ΔMD-global + 0.02 × ΔESR] of ≥ 1.15 were diagnostic of a flare. Flare scores increase with flare severity. Conclusions Consensus has been reached on preliminary criteria for global flares in cSLE. Further validation studies are needed to confirm the usefulness of the cSLE flare criteria in research and for clinical care. PMID:21618452

  18. Effect of Truncating AUC at 12, 24 and 48 hr When Evaluating the Bioequivalence of Drugs with a Long Half-Life.

    PubMed

    Moreno, Isabel; Ochoa, Dolores; Román, Manuel; Cabaleiro, Teresa; Abad-Santos, Francisco

    2016-01-01

    Bioequivalence studies of drugs with a long half-life require long periods of time for pharmacokinetic sampling. The latest update of the European guideline allows the area under the curve (AUC) truncated at 72 hr to be used as an alternative to AUC0-t as the primary parameter. The objective of this study was to evaluate the effect of truncating the AUC at 48, 24 and 12 hr on the acceptance of the bioequivalence criterion as compared with truncation at 72 hr in bioequivalence trials. The effect of truncated AUC on the within-individual coefficient of variation (CVw) and on the ratio of the formulations was also analysed. Twenty-eight drugs were selected from bioequivalence trials. Pharmacokinetic data were analysed using WinNonLin 2.0 based on the trapezoidal method. Analysis of variance (ANOVA) was performed to obtain the ratios and 90% confidence intervals for AUC at different time-points. The degree of agreement of AUC0-72 in relation to AUC0-48 and AUC0-24, according to the Landis and Koch classification, was 'almost perfect'. Statistically significant differences were observed when the CVw of AUC truncated at 72, 48 and 24 hr was compared with the CVw of AUC0-12. There were no statistically significant differences in the AUC ratio at any time-point. Compared to AUC0-72, Pearson's correlation coefficient for mean AUC, AUC ratio and AUC CVw was worse for AUC0-12 than AUC0-24 or AUC0-48. These preliminary results could suggest that AUC truncation at 24 or 48 hr is adequate to determine whether two formulations are bioequivalent. © 2015 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

  19. A case of pediatric live-donor liver transplantation with a left lateral segment reduction by a linear stapler after reperfusion.

    PubMed

    Zenitani, Masahiro; Ueno, Takehisa; Nara, Keigo; Nakahata, Kengo; Uehara, Shuichiro; Soh, Hideki; Oue, Takaharu; Kondo, Hiroki; Nagano, Hiroaki; Usui, Noriaki

    2014-09-01

    In pediatric LDLT, graft reduction is sometimes required because of the graft size mismatch. Dividing the portal triad and hepatic veins with a linear stapler is a rapid and safe method of reduction. We herein present a case with a left lateral segment reduction achieved using a linear stapler after reperfusion in pediatric LDLT. The patient was a male who had previously undergone Kasai procedure for biliary atresia. We performed the LDLT with his father's lateral segment. According to the pre-operative volumetry, the GV/SLV ratio was 102.5%. As the patient's PV was narrow, sclerotic and thick, we decided to put an interposition with the IMV graft of the donor between the confluence and the graft PV. The graft PV was anastomosed to the IMV graft. The warm ischemic time was 34 min, and the cold ischemic time was 82 min. The ratio of the graft size to the recipient weight (G/R ratio) was 4.2%. After reperfusion, we found that the graft had poor perfusion and decided to reduce the graft size. We noted good perfusion in the residual area after the lateral edge was clamped with an intestinal clamp. The liver tissue was sufficiently fractured with an intestinal clamp and then was divided with a linear stapler. The final G/R ratio was 3.6%. The total length of the operation was 12 h and 20 min. The amount of blood lost was 430 mL. No surgical complications, including post-operative hemorrhage and bile leakage, were encountered. We believe that using the linear stapler decreased the duration of the operation and was an acceptable technique for reducing the graft after reperfusion. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Acceptor Percolation Determines How Electron-Accepting Additives Modify Transport of Ambipolar Polymer Organic Field-Effect Transistors.

    PubMed

    Ford, Michael J; Wang, Ming; Bustillo, Karen C; Yuan, Jianyu; Nguyen, Thuc-Quyen; Bazan, Guillermo C

    2018-06-18

    Organic field-effect transistors (OFETs) that utilize ambipolar polymer semiconductors can benefit from the ability of both electron and hole conduction, which is necessary for complementary circuits. However, simultaneous hole and electron transport in organic field-effect transistors result in poor ON/OFF ratios, limiting potential applications. Solution processing methods have been developed to control charge transport properties and transform ambipolar conduction to hole-only conduction. The electron-acceptor phenyl-C61-butyric acid methyl ester (PC 61 BM), when mixed in solution with an ambipolar semiconducting polymer, can reduce electron conduction. Unipolar p-type OFETs with high, well-defined ON/OFF ratios and without detrimental effects on hole conduction are achieved for a wide range of blend compositions, from 95:5 to 5:95 wt % semiconductor polymer:PC 61 BM. When introducing the alternative acceptor N, N'-bis(1-ethylpropyl)-3,4:9,10-perylenediimide (PDI), high ON/OFF ratios are achieved for 95:5 wt % semiconductor polymer:PDI; however, electron conduction increases for 50:50 and 5:95 wt % semiconductor polymer:PDI. As described within, we show that electron conduction is practically eliminated when additive domains do not percolate across the OFET channel, that is, electrons are "morphologically trapped". Morphologies were characterized by optical, electron, and atomic force microscopy as well as X-ray scattering techniques. PC 61 BM was substituted with an endohedral Lu 3 N fullerene, which enhanced contrast in electron microscopy and allowed for more detailed insight into the blend morphologies. Blends with alternative, nonfullerene acceptors further emphasize the importance of morphology and acceptor percolation, providing insights for such blends that control ambipolar transport and ON/OFF ratios.

Top