Science.gov

Sample records for accessory glands mags

  1. Accessory parotid gland tumors

    PubMed Central

    Ramachar, Sreevathsa M.; Huliyappa, Harsha A.

    2012-01-01

    Tumors of accessory parotid gland are considered in the differential diagnosis of a mid cheek mass. Parotidectomy is the procedure of choice. All pathological types of parotid main gland tumors occur in the accessory parotid gland also. Presenting as a mid cheek or infrazygomatic mass, the tumors of this accessory parotid gland are notorious for recurrences, if adequate margins are not achieved. We describe two such cases of such a tumor. 40-year-old male with a slowly progressive mid cheek mass was operated by a mid cheek incision. Histopathology of the tumor was pleomorphic adenoma. Facial nerve paresis recovered complelety in 6 months. A 52-year-old female with progressive mid cheek mass who underwent parotidectomy and neck dissection by a modified Blair's incision was diagnosed with extranodal marginal zone lymphoma with focal transformation to a diffuse large B-cell lymphoma. Chemotherapy with CHOP regime was initiated. There was no recurrence at 6 months of follow-up. Lymphoma of accessory parotid gland is a very rare tumor. Standard parotidectomy incision is advocated to prevent damage to facial nerve branches. PMID:23483721

  2. Accessory suprarenal gland: report of a case.

    PubMed

    Kirici, Y; Mas, M R; Saglamkaya, U; Oztas, E; Ozan, H

    2001-06-01

    The suprarenal glands are normally located at the superomedial aspect of the kidneys. Accessory cortical masses are seen in approximately half of the newborn but usually disappear later. Several cases with accessory cortical tissues located near the main suprarenal glands have been reported but their usual locations have been rarely described. Here we report a case with accessory cortical tissue located on the right in the retrocrural space with compression symptoms. Such a lesion may be confused with lymphadenopathy radiologically.

  3. Sialolithiasis of an accessory parotid gland: an unusual case.

    PubMed

    Debnath, S C; Adhyapok, A K

    2015-09-01

    We report a rare case of sialolithiasis of an accessory parotid gland, which was located anteromedial to the masseter muscle and isolated from the main parotid gland. The calculus developed from this accessory gland, and the main gland was free of lithiasis and inflammation. To our knowledge, there is no reported case of 14 stones in an accessory parotid salivary gland. The calculus was removed through a standard incision without injury to the facial nerve or a salivary fistula. PMID:26048098

  4. Adenoid cystic carcinoma of the accessory parotid gland.

    PubMed

    Baklacı, Deniz; Güngör, Volkan; Özcan, Müge; Yılmaz, Yavuz Fuat; Ünal, Adnan; Çolak, Aysel

    2015-01-01

    Accessory parotid gland is a small salivary gland tissue separated from main part of parotid gland. It is located on the masseter muscle anterior to the Stensen's duct. Tumors of accessory parotid gland are rare. In this article, we report an unusual case of adenoid cystic carcinoma involving accessory parotid gland. The patient presented with a progressively growing mass in the middle portion of her cheek. She underwent a partial parotidectomy including both the superficial and accessory lobes. The histopathologic diagnosis was adenoid cystic carcinoma of cribriform type. PMID:26476520

  5. Ostensible oncocytoma of accessory lacrimal glands.

    PubMed

    Pecorella, I; Garner, A

    1997-03-01

    Benign oncocytomas of the accessory lacrimal glands can be found in the lacrimal caruncle, plica semilunaris or conjunctival fornices, but are extremely rare. A series of 15 supposed oncocytomas of the ocular adnexa was reviewed retrospectively, and histological differences were noted with respect to the parotid gland counterpart. Lesions could be divided into three histological groups: (1) tumours composed of tubules lined by tall columnar epithelium with finely granular cytoplasm; the tubules often had dilated lumens containing mucinous secretion; (2) cystic tumours with prominent epithelial tufts projecting from much of the cyst wall; (3) tumours with solid areas composed of variably cuboidal or polygonal cells, largely in trabecular arrangement, and co-existing with the previously described tubular and cystic elements. A striking resemblance to Warthin's tumour without a lymphocytic component, such as may affect the parotid salivary gland, was noted in several tumours.

  6. [Occurrence and structure of accessory adrenal glands in Wistar rats].

    PubMed

    Schwabedal, P E; Partenheimer, U

    1983-01-01

    In complete series of histological sections through the entire abdomen of one normal Wistar-rat, one untreated and two bilaterally adrenalectomized, spontaneously hypertensive Wistar-rats accessory suprarenal glands were found in each case. The detailed findings in the various groups of animals investigated were as follows: (1) In the normal animal 10 accessory suprarenal glands were present. They consisted of tiny aggregates of cortical cells and were surrounded by a thin layer of collageneous fibers. The diameters of the accessory suprarenal complexes were in the order of 0.3 mm. (2) In the untreated, spontaneously hypertensive rat three accessory suprarenal glands were found. However, in contrast to what was seen in the normal rat, these complexes were larger and had diameters of up to 1 mm. Some of these accessory suprarenal glands consisted almost exclusively of small, chromophobe cells, whereas in others a rim of such cells was seen to surround a central core of larger and more acidophile cortical cells. There were few and collapsed capillaries. (3) In the bilaterally adrenalectomized, spontaneously hypertensive rats three, respectively four, accessory suprarenal glands were found. They were situated in the retroperitoneum and partly within the adipose capsule of the kidney but never in the place of the exstirpated main suprarenal glands. In one case an accessory gland was found within the fibrous capsule of the kidney and seen to compress the renal parenchyma. In the bilaterally adrenalectomized animals the average diameters of the accessory glands were larger than in the other groups reaching values of up to 5 mm. At least in both animals one of the accessory glands had a diameter comparable to that of the normal suprarenal gland of an untreated animal. The capillaries were dilated and their number was increased in comparison to what was seen in the other groups. In certain regions the cortical tissue of the accessory glands had an appearance resembling

  7. Wide excision of accessory parotid gland with anterior approach.

    PubMed

    Choi, Hwan Jun; Lee, Young Man; Kim, Jun Hyuk; Tark, Min Seong; Lee, Jang Hyun

    2012-01-01

    Accessory parotid gland tissue has been described as salivary tissue adjacent to the Stensen duct that is distinctly separate from the main body of the parotid gland. Of all parotid gland tumors, 1% to 8% arise from the accessory parotid gland. Little is known about the accessory parotid gland, and it is seldom mentioned in the literature. Between 1999 and 2010, we have treated and followed 8 patients with tumors of the accessory parotid gland. There were 5 males and 3 females with a mean age of 35 years. They all presented with an asymptomatic cheek mass, and 4 of them underwent fine-needle aspiration. Ultrasound or computed tomographic scan was used in all patients. All the patients underwent surgical intervention with standard parotidectomy incision and anterior extension. The mean follow-up time was 44 months (range, 6-120 months). Seven patients had benign disease. Four cases were pleomorphic adenoma, and the remaining 3 benign cases were parotid cyst, basal cell adenoma, and hemangioma. Only 1 patient had a malignant tumor that was a lymphoepithelioma-like carcinoma. In 7 cases, wide excision (excision of mass and accessory lobe of the parotid gland) was done because of the intra-accessory parotid gland lesion. One patient had concomitant superficial parotidectomy because the tumor was located very close to and has involved the parotid gland proper. There was no serious postoperative complication and recurrence. Prudent preoperative diagnostic evaluation and meticulous surgical approach are the keys to successful management of midcheek lesions. A wide excision of the accessory lobe of the parotid gland can be a definitive surgery in case of solitary tumor with an intact parotid fascia, and wide excision with anterior approach through a standard parotidectomy incision is preferred to a direct incision over the mass.

  8. Alternative delivery of male accessory gland products

    PubMed Central

    2014-01-01

    To increase fertilization success, males transfer accessory gland products (Acps). Several species have evolved unconventional Acps transfer modes, meaning that Acps are transferred separately from the sperm. By surveying the sperm-free Acps transfer cases, we show that these animals have evolved a common strategy to deliver Acps: they all inject Acps directly through the partner’s body wall into the hemolymph. Our review of this mode of Acps transfer reveals another striking similarity: they all transfer sperm in packages or via the skin, which may leave little room for Acps transfer via the conventional route in seminal fluid. We synthesise the knowledge about the function, and the effects in the recipients, of the Acps found in the widely diverse taxa (including earthworms, sea slugs, terrestrial snails, scorpions and salamanders) that inject these substances. Despite the clearly independent evolution of the injection devices, these animals have evolved a common alternative strategy to get their partners to accept and/or use their sperm. Most importantly, the evolution of the injection devices for the delivery of Acps highlights how the latter are pivotal for male reproductive success and, hence, strongly influence sexual selection. PMID:24708537

  9. Juvenile hormone regulation of male accessory gland activity in the red flour beetle, Tribolium castaneum

    PubMed Central

    Parthasarathy, R.; Tan, A.; Sun, Z.; Chen, J.; Rainkin, M.; Palli, S. R.

    2009-01-01

    Male accessory gland proteins (Acps) act as key modulators of reproductive success in insects by influencing the female reproductive physiology and behavior. We used custom microarrays and identified 112 genes that were highly expressed in male accessory glands (MAG) in the red flour beetle, Tribolium castaneum. Out of these 112 identified genes, 59 of them contained sequences coding for signal peptide and cleavage site and the remaining 53 contained transmembrane domains. The expression of 14 these genes in the MAG but not in other tissues of male or female was confirmed by quantitative real-time PCR. In virgin males, juvenile hormone (JH) levels increased from second day post adult emergence (PAE), remained high on third day PAE and declined on fourth day PAE. The ecdysteroid titers were high soon after adult emergence but declined to minimal levels from 1-5 days PAE. Feeding of juvenile hormone analog, hydroprene, but not the ecdysteroid analog, RH-2485, showed an increase in size of MAGs, as well as an increase in total RNA and protein content of MAG. Hydroprene treatment also increased the expression Acp genes in the MAG. RNAi-mediated knock-down in the expression of JHAMT gene decreased the size of MAGs and expression of Acps. JH deficiency influenced male reproductive fitness as evidenced by a less vigor in mating behavior, poor sperm transfer, low egg and the progeny production by females mated with the JH deficient males. These data suggest a critical role for JH in the regulation of male reproduction especially through MAG secretions. PMID:19324087

  10. Morphology and protein patterns of honey bee drone accessory glands.

    PubMed

    Cruz-Landim, Carminda da; Dallacqua, Rodrigo Pires

    2005-09-30

    We used light and transmission electron microscopy to examine the morphology of the accessory glands of immature and mature adult males of Apis mellifera L. We also made an electrophoretic analysis of the protein content of the mature gland. The glands of the immature male actively secrete a mucous substance that can be seen in the lumen of the gland of the mature male. This secretion stains with mercury bromophenol blue and with periodic acid-Schiff reaction, which stain glyconjugates. The protein content was higher in the lumen secretion than in the gland wall extracts. The electrophoresis patterns of the wall extracts were different from those of the secretion found in the gland lumen.

  11. Morphology and protein patterns of honey bee drone accessory glands.

    PubMed

    Cruz-Landim, Carminda da; Dallacqua, Rodrigo Pires

    2005-01-01

    We used light and transmission electron microscopy to examine the morphology of the accessory glands of immature and mature adult males of Apis mellifera L. We also made an electrophoretic analysis of the protein content of the mature gland. The glands of the immature male actively secrete a mucous substance that can be seen in the lumen of the gland of the mature male. This secretion stains with mercury bromophenol blue and with periodic acid-Schiff reaction, which stain glyconjugates. The protein content was higher in the lumen secretion than in the gland wall extracts. The electrophoresis patterns of the wall extracts were different from those of the secretion found in the gland lumen. PMID:16342031

  12. An accessory thyroid gland that presented tumor-like images.

    PubMed

    Takemoto, Nobuyuki; Koyanagi, Ai; Koike, Junko; Yamamoto, Hiroshi

    2013-04-01

    A 26-year-old woman presented with right breast pain and itching. Incidentally, a firm, non-tender, movable mass (3 cm in diameter) located in the lower right part of the neck was identified by palpation. Ultrasonography revealed a clearly demarcated dumbbell-shaped mass with homogenous hypo- (cranial side) and hyper-echogenicity (caudal side) compared with the thyroid gland. Computed tomography scan and magnetic resonance imaging presented images that were different from thyroid gland substance. The right thyroid lobe was strongly compressed by the mass. Hyperparathyroidism was ruled out by laboratory testing. The patient solicited resection of the mass despite recommendations for core needle biopsy, and it was removed surgically. The mass was surrounded by a thin capsule and was not connected with the thyroid gland. Pathological examinations revealed normal thyroid gland tissue. The final diagnosis was an accessory thyroid gland. Accessory thyroid glands should be considered as a possible diagnosis when nodules around the main thyroid gland are encountered.

  13. Identification and comparative analysis of accessory gland proteins in Orthoptera.

    PubMed

    Braswell, W Evan; Andrés, José A; Maroja, Luana S; Harrison, Richard G; Howard, Daniel J; Swanson, Willie J

    2006-09-01

    Accessory reproductive gland proteins (Acps) in Drosophila evolve quickly and appear to play an important role in ensuring the fertilization success of males. Moreover, Acps are thought to be involved in establishing barriers to fertilization between closely related species. While accessory glands are known to occur in the males of many insect groups, the proteins that are passed on to females by males during mating have not been well characterized outside of Drosophila. To gain a better understanding of these proteins, we characterized ESTs from the accessory glands of two cricket species, Allonemobius fasciatus and Gryllus firmus. Using an expressed sequence tag (EST) approach, followed by bioinformatic and evolutionary analyses, we found that many proteins are secreted and, therefore, available for transfer to the female during mating. Further, we found that most ESTs are novel, showing little sequence similarity between taxa. Evolutionary analyses suggest that cricket proteins are subject to diversifying selection and indicate that Allonemobius is much less polymorphic than Gryllus. Despite rapid nucleotide sequence divergence, there appears to be functional conservation of protein classes among Drosophila and cricket taxa.

  14. Two cases of non-Hodgkin's lymphoma in the accessory parotid gland.

    PubMed

    Fujimura, Kazunobu; Yoshida, Masafumi; Sugimoto, Takuya; Kuroda, Yoshiki; Fujiyoshi, Tatsuya

    2004-06-01

    Primary malignant lymphomas in the salivary glands are relatively rare and tumors of the accessory parotid gland comprise only 1% of parotid tumors. We present two cases with a painless swelling of the cheek region. In both cases histological diagnoses of primary non-Hodgkin's lymphoma were made following complete excision of the accessory parotid gland tumor. PMID:15121232

  15. Pleomorphic adenoma of an accessory submandibular salivary gland: a rare entity.

    PubMed

    Desai, Rajiv S; Meshram, Deepashree; Jangam, Sagar S; Singh, Jatinder S

    2015-10-01

    An accessory submandibular salivary gland is a rare anatomical variant, and a tumour within one is even rarer. We describe a 54-year-old man who presented with a slowly-enlarging mass in the right submandibular region which on magnetic resonance imaging (MRI) seemed to be close to, but not arising from, the right submandibular salivary gland. This was found to be a benign pleomorphic adenoma arising from an accessory submandibular salivary gland. To our knowledge it is only the second report of a pleomorphic adenoma that developed within an accessory submandibular salivary gland.

  16. Role of the Accessory Parotid Gland in the Etiology of Parotitis: Statistical Analysis of Sialographic Features

    PubMed Central

    Zhu, Wangyong; Hu, Fengchun; Liu, Xingguang; Guo, Songcan; Tao, Qian

    2016-01-01

    This retrospective study aimed to identify if the existence of the accessory parotid gland correlated with the etiology of parotitis. This may aid the development of better treatment strategies in the future. Sialographic features of cases with parotitis and healthy subjects were reviewed. The chi-square test was used to compare the incidence of accessory parotid gland between the groups. The Student’s t test was used to compare the length of Stensen’s duct, the length from the orifice to the confluence of the accessory duct, and the angle between the accessory duct and Stensen’s duct between the groups. The incidence of accessory parotid gland in patients with parotitis was 71.8% (28/39), which was significantly higher than that in healthy subjects (P = 0.005). Patients with parotitis had a longer Stensen’s duct than healthy subjects (P = 0.003). There was no significant difference in the length from the orifice to the confluence of the accessory duct or the angle between the accessory duct and Stensen’s duct (P = 0.136 and 0.511, respectively) between the groups. The accessory parotid gland might play a role in the pathogenesis of parotitis. The existence of an accessory parotid gland is likely to interfere with salivary flow. Computational fluid dynamics analysis of salivary flow in the ductal system would be useful in future etiologic studies on parotitis. PMID:26913509

  17. Role of the Accessory Parotid Gland in the Etiology of Parotitis: Statistical Analysis of Sialographic Features.

    PubMed

    Zhu, Wangyong; Hu, Fengchun; Liu, Xingguang; Guo, Songcan; Tao, Qian

    2016-01-01

    This retrospective study aimed to identify if the existence of the accessory parotid gland correlated with the etiology of parotitis. This may aid the development of better treatment strategies in the future. Sialographic features of cases with parotitis and healthy subjects were reviewed. The chi-square test was used to compare the incidence of accessory parotid gland between the groups. The Student's t test was used to compare the length of Stensen's duct, the length from the orifice to the confluence of the accessory duct, and the angle between the accessory duct and Stensen's duct between the groups. The incidence of accessory parotid gland in patients with parotitis was 71.8% (28/39), which was significantly higher than that in healthy subjects (P = 0.005). Patients with parotitis had a longer Stensen's duct than healthy subjects (P = 0.003). There was no significant difference in the length from the orifice to the confluence of the accessory duct or the angle between the accessory duct and Stensen's duct (P = 0.136 and 0.511, respectively) between the groups. The accessory parotid gland might play a role in the pathogenesis of parotitis. The existence of an accessory parotid gland is likely to interfere with salivary flow. Computational fluid dynamics analysis of salivary flow in the ductal system would be useful in future etiologic studies on parotitis. PMID:26913509

  18. Molecular population genetics of male accessory gland proteins in Drosophila.

    PubMed

    Begun, D J; Whitley, P; Todd, B L; Waldrip-Dail, H M; Clark, A G

    2000-12-01

    Drosophila seminal proteins have an unusually high rate of molecular sequence evolution, suggesting either a high rate of neutral substitution or rapid adaptive evolution. To further quantify patterns of polymorphism and divergence in genes encoding seminal proteins, also called accessory gland proteins (Acp's), we conducted a sequencing survey of 10 Acp genes in samples of Drosophila melanogaster and D. simulans (Acp29AB, Acp32CD, Acp33A, Acp36DE, Acp53Ea, Acp62F, Acp63F, Acp76A, Acp95EF, and Acp98AB). Mean heterozygosity at replacement sites in D. simulans was 0.0074 for Acp genes and 0.0013 for a set of 19 non-Acp genes, and mean melanogaster-simulans divergence at replacement sites was 0.0497 for Acp genes and 0.0107 at non-Acp genes. The elevated divergence of Acp genes is thus accompanied by elevated within-species polymorphism. In addition to the already-reported departures of Acp26A, Acp29AB, and Acp70A from neutrality, our data reject neutrality at Acp29AB and Acp36DE in the direction of excess replacements in interspecific comparisons.

  19. Proteome analysis of male accessory gland secretions in oriental fruit flies reveals juvenile hormone-binding protein, suggesting impact on female reproduction.

    PubMed

    Wei, Dong; Li, Hui-Min; Tian, Chuan-Bei; Smagghe, Guy; Jia, Fu-Xian; Jiang, Hong-Bo; Dou, Wei; Wang, Jin-Jun

    2015-01-01

    In insects, the accessory gland proteins (Acps) secreted by male accessory glands (MAGs) account for the majority of seminal fluids proteins. Mixed with sperm, they are transferred to the female at mating and so impact reproduction. In this project, we identified 2,927 proteins in the MAG secretions of the oriental fruit fly Bactrocera dorsalis, an important agricultural pest worldwide, using LC-MS analysis, and all sequences containing open reading frames were analyzed using signalP. In total, 90 Acps were identified. About one third (26) of these 90 Acps had a specific functional description, while the other two thirds (64) had no functional description including dozens of new classes of proteins. Hence, several of these novel Acps were abundant in the MAG secretions, and we confirmed their MAG-specific expression by qPCR. Finally and interestingly, one of these novel proteins was functionally predicted as juvenile hormone-binding protein, suggesting the impact of Acps with reproductive events in the female. Our results will aid in the development of an experimental method to identify Acps in insects, and in turn this information with new Acps in B. dorsalis will pave the way of further exploration their function in reproduction and potential development as new insecticide targets.

  20. Proteome analysis of male accessory gland secretions in oriental fruit flies reveals juvenile hormone-binding protein, suggesting impact on female reproduction

    PubMed Central

    Wei, Dong; Li, Hui-Min; Tian, Chuan-Bei; Smagghe, Guy; Jia, Fu-Xian; Jiang, Hong-Bo; Dou, Wei; Wang, Jin-Jun

    2015-01-01

    In insects, the accessory gland proteins (Acps) secreted by male accessory glands (MAGs) account for the majority of seminal fluids proteins. Mixed with sperm, they are transferred to the female at mating and so impact reproduction. In this project, we identified 2,927 proteins in the MAG secretions of the oriental fruit fly Bactrocera dorsalis, an important agricultural pest worldwide, using LC-MS analysis, and all sequences containing open reading frames were analyzed using signalP. In total, 90 Acps were identified. About one third (26) of these 90 Acps had a specific functional description, while the other two thirds (64) had no functional description including dozens of new classes of proteins. Hence, several of these novel Acps were abundant in the MAG secretions, and we confirmed their MAG-specific expression by qPCR. Finally and interestingly, one of these novel proteins was functionally predicted as juvenile hormone-binding protein, suggesting the impact of Acps with reproductive events in the female. Our results will aid in the development of an experimental method to identify Acps in insects, and in turn this information with new Acps in B. dorsalis will pave the way of further exploration their function in reproduction and potential development as new insecticide targets. PMID:26582577

  1. Reproductive biology in Anophelinae mosquitoes (Diptera, Culicidae): Fine structure of the female accessory gland.

    PubMed

    Laghezza Masci, Valentina; Di Luca, Marco; Gambellini, Gabriella; Taddei, Anna Rita; Belardinelli, Maria Cristina; Guerra, Laura; Mazzini, Massimo; Fausto, Anna Maria

    2015-07-01

    The morphology and ultrastructure of female accessory reproductive glands of Anopheles maculipennis s.s., Anopheles labranchiae and Anopheles stephensi were investigated by light and electron microscopy. The reproductive system in these species is characterized by two ovaries, two lateral oviducts, a single spermatheca and a single accessory gland. The gland is globular and has a thin duct which empties into the vagina, near the opening of the spermathecal duct. Significant growth of the accessory reproductive gland is observed immediately after blood meal, but not at subsequent digestion steps. At ultrastructural level, the gland consists of functional glandular units belonging to type 3 ectodermal glands. The secretory cells are elongated and goblet shaped, with most of their cytoplasm and large nucleus in the basal part, close to the basement lamella. Finely fibrous electron-transparent material occupies the secretory cavity that is in contact with the end of a short efferent duct (ductule) emerging from the gland duct. The present study is the first detailed description of female accessory gland ultrastructure in Anophelinae and provides insights into the gland's functional role in the reproductive biology of these insects.

  2. Photoperiod regulates growth of male accessory glands through juvenile hormone signaling in the linden bug, Pyrrhocoris apterus.

    PubMed

    Urbanová, Veronika; Bazalová, Olga; Vaněčková, Hanka; Dolezel, David

    2016-03-01

    Adult reproductive diapause is characterized by lower behavioral activity, ceased reproduction and absence of juvenile hormone (JH). The role of JH receptor Methoprene-tolerant (Met) in female reproduction is well established; however, its function in male reproductive development and behavior is unclear. In the bean bug, Riptortus pedestris, circadian genes are essential for mediating photoperiodically-dependent growth of the male accessory glands (MAGs). The present study explores the role of circadian genes and JH receptor in male diapause in the linden bug, Pyrrhocoris apterus. These data indicate that circadian factors Clock, Cycle and Cry2 are responsible for photoperiod measurement, whereas Met and its partner protein Taiman participate in JH reception. Surprisingly, knockdown of the JH receptor neither lowered locomotor activity nor reduced mating behavior of males. These data suggest existence of a parallel, JH-independent or JH-upstream photoperiodic regulation of reproductive behavior. PMID:26826599

  3. Steroidogenesis by testis and accessory glands of the Lusitanian toadfish, Halobatrachus didactylus, during reproductive season.

    PubMed

    Modesto, Teresa; Freitas, Ana M M S; Canario, Adelino V M

    2015-11-01

    In teleost fish sex steroids are essential for gonadal function and have marked effects in reproductive and agonistic behavior and in the expression of secondary sexual characteristics. The Lusitanian toadfish, Halobatrachus didactylus, has two male morphotypes: type I males are territorial nest-holders and have large accessory glands while type II males are smaller, have a relatively large testis and small accessory glands. In the present study, the steroidogenic activity of the testis and accessory testicular glands of the Lusitanian toadfish were examined in vitro as well as their presence in urine. The testis of type I males produced 11-ketotestosterone (11KT) and 11β-hydroxy-4-androstene-3,17-dione (11βA) from tritiated 17-hydroxyprogesterone, while those of type II males produced testosterone (T) and 11β,17β-dihydroxy-4-andosten-3-one (11βT), but not 11KT. Additionally, the testis and accessory glands of both morphs produced mostly 5β,3α-reduced and 17,20α-hydroxylated metabolites. Type I, but not of type II, males synthesised 5β-reduced androgens in their accessory glands. The presence of 11βA exclusively in the urine of type I males during reproductive season suggests an association with maintenance of secondary sexual characteristics and behavior in this morph. The urine of both types of males contained two 5α-androstane and 5β-pregnane glucuronides. Among the latter steroids, those that are 17,21-dihydroxylated are potentially metabolites from cortisol and were found only in type I males during the spawning season. The diversity of metabolites produced by the testis and accessory glands and the presence of some in urine is suggestive of a potential role in chemical communication and reproductive behavior.

  4. Morphology of accessory genital glands of spotted paca (Agouti paca Linnaeus, 1766).

    PubMed

    Borges, Edson Moreira; Branco, Érika; de Lima, Ana Rita; Leal, Leonardo Martins; Martins, Leandro Luiz; Reis, Ana Carolina Gonçalves; Cruz, Claudinei; Machado, Márcia Rita Fernandes; Miglino, Maria Angelica

    2014-02-01

    The spotted paca is the second largest rodent in Brazil, where it is of great economic interest in impoverished regions in view of its prominence as a low-cost source of protein. Little is known about the morphology of the accessory genital glands of this species. Thus, we studied the position and morphology of the genitals in ten adult male spotted pacas. The animals were divided into two groups, five animals were used for fixing of samples in 10% aqueous formaldehyde for macroscopic studies and the other five animals were designated for microscopic analysis. These were arranged in pairs and had the vesicular, prostate, coagulating and bulbourethral glands identified, being structured as mucous glands, which lead into the pelvic urethra. It was concluded that the accessory genital glands found in the paca are the same as those found in most rodents, showing similar histological aspects.

  5. Study on development of accessory sex glands in prepubertal kids using two-dimensional ultrasonography

    PubMed Central

    Kumari, Sonu; Luthra, R. A.; Chandolia, R. K.; Kumar, Sandeep; Kumar, Parveen; Devender; Kumar, Ankit; Bishnoi, Nidhi; Bishnoi, Sunil

    2016-01-01

    Aim: The present study was undertaken to study growth pattern of accessory sex glands in prepubertal kids from 2 weeks to 6 months of age using two-dimensional ultrasonography. Materials and Methods: The study was conducted on six Beetal kids. The scanning of accessory sex glands was done in standing position using rectal probe and measurements were recorded. Data collected were statistically analyzed using one-way ANOVA followed by Duncan multiple range test was performed using the SPSS (16.0) system for windows. Results: With the advancement of age all the dimensions of glands increased. Both the lobes of prostate gland showed an increase in width with advancement of age. Width of prostate above the urethra (W1) showed a significant increase at 2, 10, and 20 weeks of age, whereas non-significant increase from 2 to 8, 10 to 19, and 20 to 24 weeks of age was recorded. Width of prostate below the urethra (W2) showed a significant increase at 20 weeks of age, whereas non-significant increase was recorded during rest of period of growth. Left and right bulbourethral gland showed a similar pattern of growth with the advancement of age. The circumference dimensions increased significantly at 2, 16, 20, and 21 weeks of age for both glands. The increase was non-significant from 4 to 14, 16 to 19, and 20 to 23 weeks of age. The same pattern was observed for left and right seminal vesicular gland. Conclusion: Significant growth in three accessory sex glands in prepubertal kids was not observed at the same age. The trend observed was that the prostate was the first gland to show significant growth at 10 weeks of age followed by a significant increase in seminal vesicles and bulbourethral gland at 14 and 16 weeks of age, respectively. PMID:27182127

  6. Ultrastructure of male reproductive accessory glands and ejaculatory duct in the Queensland fruit fly, Bactrocera tryoni (Diptera: Tephritidae).

    PubMed

    Radhakrishnan, Preethi; Marchini, Daniela; Taylor, Phillip W

    2009-05-01

    Ultrastructure of male reproductive accessory glands and ejaculatory duct in the Queensland fruit fly (Q-fly), Bactrocera tryoni, were investigated and compared with those of other tephritid flies. Male accessory glands were found to comprise one pair of mesodermic glands and three pairs of ectodermic glands. The mesodermic accessory glands consist of muscle-lined, binucleate epithelial cells, which are highly microvillated and extrude electron-dense secretions by means of macroapocrine transport into a central lumen. The ectodermic accessory glands consist of muscle-lined epithelial cells which have wide subcuticular cavities, lined with microvilli. The electron-transparent secretions from these glands are first extruded into the cavities and then forced out through small pores of the cuticle into the gland lumen. Secretions from the two types of accessory glands then flow into the ejaculatory duct, which is highly muscular, with epithelial cells rich in rough endoplasmic reticulum and lined with a thick, deeply invaginated cuticle. While there are some notable differences, reproductive accessory glands of male Q-flies generally resemble those of the olive fruitfly, Bactrocera oleae, and to a lesser extent the Mediterranean fruit fly, Ceratitis capitata. PMID:19026762

  7. Adenomatosis of accessory salivary glands of the lip. Report of two cases.

    PubMed

    Ahrén, C; Lindström, J

    1977-01-01

    Two cases of an unusual tumour of accessory salivary glands are presented. The histological examination revealed that this tumour was benign and not malignant as has been suggested by others. Clinical follow-up for 8 years showed no signs of recurrence or metastases. We suggested to call it 'adenomatosis'. No extensive surgery is indicated.

  8. Transcriptome analysis to identify genes for peptides and proteins involved in immunity and reproduction from male accessory glands and ejaculatory duct of Bactrocera dorsalis.

    PubMed

    Wei, Dong; Tian, Chuan-Bei; Liu, Shi-Huo; Wang, Tao; Smagghe, Guy; Jia, Fu-Xian; Dou, Wei; Wang, Jin-Jun

    2016-06-01

    In the male reproductive system of insects, the male accessory glands and ejaculatory duct (MAG/ED) are important organs and their primary function is to enhance the fertility of spermatozoa. Proteins secreted by the MAG/ED are also known to induce post-mating changes and immunity responses in the female insect. To understand the gene expression profile in the MAG/ED of the oriental fruit fly Bactrocera dorsalis (Hendel), that is an important pest in fruits, we performed an Illumina-based deep sequencing of mRNA. This yielded 54,577,630 clean reads corresponding to 4.91Gb total nucleotides that were assembled and clustered to 30,669 unigenes (average 645bp). Among them, 20,419 unigenes were functionally annotated to known proteins/peptides in Gene Orthology, Clusters of Orthologous Groups, Kyoto Encyclopedia of Genes and Genomes pathway databases. Typically, many genes were involved in immunity and these included microbial recognition proteins and antimicrobial peptides. Subsequently, the inducible expression of these immunity-related genes was confirmed by qRT-PCR analysis when insects were challenged with immunity-inducible factors, suggesting their function in guaranteeing fertilization success. Besides, we identified some important reproductive genes such as juvenile hormone- and ecdysteroid-related genes in this de novo assembly. In conclusion, this transcriptomic sequencing of B. dorsalis MAG/ED provides insights to facilitate further functional research of reproduction, immunity and molecular evolution of reproductive proteins in this important agricultural pest.

  9. Minimally invasive endoscopic resection of benign tumours of the accessory parotid gland: an updated approach.

    PubMed

    Li, Biao; Zhang, Lei; Zhao, Zeliang; Shen, Guofang; Wang, Xudong

    2013-06-01

    The most common conventional approaches for the resection of benign tumours in the accessory parotid gland are a standard parotidectomy incision, a modified standard parotidectomy incision, or a face-lift incision. The resulting scars may severely affect the patient's postoperative appearance. The previously reported endoscopically assisted approach offers a less aesthetically invasive technique, but it may still leave a visible preauricular scar 4-5 cm long. We have used a modified endoscopic approach with minimal, and concealed, incisions for the resection of benign tumours in the accessory parotid gland. Five patients were diagnosed by physical examination, imaging, and preoperative fine-needle aspiration biopsy. They had endoscopically assisted resections using our modified approach, and we evaluated its feasibility. All the resections were successful. The mean operating time was 108 min (range 90-130). The postoperative scars were concealed and aesthetically satisfactory. There were no facial paralyses, salivary fistulas, or recurrences in the short term. Using endoscopically assisted resection we completely removed benign tumours from the accessory parotid gland and obtained good aesthetic results. Our updated endoscopic approach for these resections is successful with shorter, concealed incisions. It is a viable alternative to conventional approaches.

  10. Accessory gland as a site for prothoracicotropic hormone controlled ecdysone synthesis in adult male insects.

    PubMed

    Hentze, Julie L; Moeller, Morten E; Jørgensen, Anne F; Bengtsson, Meghan S; Bordoy, Anna M; Warren, James T; Gilbert, Lawrence I; Andersen, Ole; Rewitz, Kim F

    2013-01-01

    Insect steroid hormones (ecdysteroids) are important for female reproduction in many insect species and are required for the initiation and coordination of vital developmental processes. Ecdysteroids are also important for adult male physiology and behavior, but their exact function and site of synthesis remains unclear, although previous studies suggest that the reproductive system may be their source. We have examined expression profiles of the ecdysteroidogenic Halloween genes, during development and in adults of the flour beetle Tribolium castaneum. Genes required for the biosynthesis of ecdysone (E), the precursor of the molting hormone 20-hydroxyecdysone (20E), are expressed in the tubular accessory glands (TAGs) of adult males. In contrast, expression of the gene encoding the enzyme mediating 20E synthesis was detected in the ovaries of females. Further, Spookiest (Spot), an enzyme presumably required for endowing tissues with competence to produce ecdysteroids, is male specific and predominantly expressed in the TAGs. We also show that prothoracicotropic hormone (PTTH), a regulator of E synthesis during larval development, regulates ecdysteroid levels in the adult stage in Drosophila melanogaster and the gene for its receptor Torso seems to be expressed specifically in the accessory glands of males. The composite results suggest strongly that the accessory glands of adult male insects are the main source of E, but not 20E. The finding of a possible male-specific source of E raises the possibility that E and 20E have sex-specific roles analogous to the vertebrate sex steroids, where males produce primarily testosterone, the precursor of estradiol. Furthermore this study provides the first evidence that PTTH regulates ecdysteroid synthesis in the adult stage and could explain the original finding that some adult insects are a rich source of PTTH. PMID:23383307

  11. Accessory gland as a site for prothoracicotropic hormone controlled ecdysone synthesis in adult male insects.

    PubMed

    Hentze, Julie L; Moeller, Morten E; Jørgensen, Anne F; Bengtsson, Meghan S; Bordoy, Anna M; Warren, James T; Gilbert, Lawrence I; Andersen, Ole; Rewitz, Kim F

    2013-01-01

    Insect steroid hormones (ecdysteroids) are important for female reproduction in many insect species and are required for the initiation and coordination of vital developmental processes. Ecdysteroids are also important for adult male physiology and behavior, but their exact function and site of synthesis remains unclear, although previous studies suggest that the reproductive system may be their source. We have examined expression profiles of the ecdysteroidogenic Halloween genes, during development and in adults of the flour beetle Tribolium castaneum. Genes required for the biosynthesis of ecdysone (E), the precursor of the molting hormone 20-hydroxyecdysone (20E), are expressed in the tubular accessory glands (TAGs) of adult males. In contrast, expression of the gene encoding the enzyme mediating 20E synthesis was detected in the ovaries of females. Further, Spookiest (Spot), an enzyme presumably required for endowing tissues with competence to produce ecdysteroids, is male specific and predominantly expressed in the TAGs. We also show that prothoracicotropic hormone (PTTH), a regulator of E synthesis during larval development, regulates ecdysteroid levels in the adult stage in Drosophila melanogaster and the gene for its receptor Torso seems to be expressed specifically in the accessory glands of males. The composite results suggest strongly that the accessory glands of adult male insects are the main source of E, but not 20E. The finding of a possible male-specific source of E raises the possibility that E and 20E have sex-specific roles analogous to the vertebrate sex steroids, where males produce primarily testosterone, the precursor of estradiol. Furthermore this study provides the first evidence that PTTH regulates ecdysteroid synthesis in the adult stage and could explain the original finding that some adult insects are a rich source of PTTH.

  12. The RED domain of Paired is specifically required for Drosophila accessory gland maturation

    PubMed Central

    Li, Li; Li, Ping; Xue, Lei

    2015-01-01

    The evolutionarily conserved paired domain consists of the N-terminal PAI and the C-terminal RED domains, each containing a helix–turn–helix motif capable of binding DNA. Despite its conserved sequence, the physiological functions of the RED domain remain elusive. Here, we constructed a prd transgene expressing a truncated Paired (Prd) protein without the RED domain, and examined its rescue ability in prd mutants. We found that the RED domain is specifically required for the expression of Acp26Aa and sex peptide in male accessory glands, and the induction of female post-mating response. Our data thus identified an important physiological function for the evolutionarily conserved RED domain. PMID:25694546

  13. The RED domain of Paired is specifically required for Drosophila accessory gland maturation.

    PubMed

    Li, Li; Li, Ping; Xue, Lei

    2015-02-01

    The evolutionarily conserved paired domain consists of the N-terminal PAI and the C-terminal RED domains, each containing a helix-turn-helix motif capable of binding DNA. Despite its conserved sequence, the physiological functions of the RED domain remain elusive. Here, we constructed a prd transgene expressing a truncated Paired (Prd) protein without the RED domain, and examined its rescue ability in prd mutants. We found that the RED domain is specifically required for the expression of Acp26Aa and sex peptide in male accessory glands, and the induction of female post-mating response. Our data thus identified an important physiological function for the evolutionarily conserved RED domain.

  14. Ability of male Queensland fruit flies to inhibit receptivity in multiple mates, and the associated recovery of accessory glands.

    PubMed

    Radhakrishnan, Preethi; Taylor, Phillip W

    2008-02-01

    Mating success of male insects is commonly determined by their ability to find and copulate with multiple females, but is also determined by their ability to transfer an effective ejaculate. In order to succeed in these tasks, males must first succeed in replenishing the necessary reproductive reserves between mating opportunities. We here investigate the ability of male Queensland fruit flies ('Q-fly') to recover from their first matings in time to both mate again the following day and to induce sexual inhibition in successive mates. We have previously found that accessory gland fluids (AGFs) transferred in the ejaculate of male Q-flies are directly responsible for induction of sexual inhibition in their mates. We here investigate changes in male accessory gland, testis and ejaculatory apodeme dimensions that are likely to reflect depletion and recovery of contents. We found no differences between virgin and previously mated males in their ability to obtain matings or to induce sexual inhibition in their mates, indicating a full recovery of the necessary reproductive reserves between mating opportunities. Whereas no changes were detected in testis or ejaculatory apodeme size following mating, the recovery of male ability to inhibit female remating was closely reflected in the mesodermal accessory gland dimensions; these accessory glands greatly diminished in size (length and area) immediately after mating, with recovery commencing between 5.5 and 11 h after mating. The accessory glands then expanded to reach their original size in time to mate the following day and induce sexual inhibition in the next mate. PMID:18083187

  15. Antigenic homogeneity of male Müllerian gland (MG) secretory proteins of a caecilian amphibian with secretory proteins of the mammalian prostate gland and seminal vesicles: evidence for role of the caecilian MG as a male accessory reproductive gland.

    PubMed

    Radha, Arumugam; Sree, Sreesha; Faisal, Kunnathodi; Kumar, G Pradeep; Oommen, Oommen V; Akbarsha, Mohammad A

    2014-10-01

    Whereas in all other vertebrates the Müllerian ducts of genetic males are aborted during development, under the influence of Müllerian-inhibiting substance, in the caecilian amphibians they are retained as a pair of functional glands. It has long been speculated that the Müllerian gland might be the male accessory reproductive gland but there has been no direct evidence to this effect. The present study was undertaken to determine whether the caecilian Müllerian gland secretory proteins would bear antigenic similarity to secretory proteins of the prostate gland and/or the seminal vesicles of a mammal. The secretory proteins of the Müllerian gland of Ichthyophis tricolor were evaluated for cross-reactivity with antisera raised against rat ventral prostate and seminal vesicle secretory proteins, adopting SDS-PAGE, two-dimensional electrophoresis and immunoblot techniques. Indeed there was a cross-reaction of five Müllerian gland secretory protein fractions with prostatic protein antiserum and of three with seminal vesicle protein antiserum. A potential homology exists because in mammals the middle group of the prostate primordia is derived from a diverticulum of the Müllerian duct. Thus this study, by providing evidence for expression of prostatic and seminal vesicle proteins in the Müllerian gland, substantiates the point that in caecilians the Müllerian glands are the male accessory reproductive glands.

  16. Antigenic homogeneity of male Müllerian gland (MG) secretory proteins of a caecilian amphibian with secretory proteins of the mammalian prostate gland and seminal vesicles: evidence for role of the caecilian MG as a male accessory reproductive gland.

    PubMed

    Radha, Arumugam; Sree, Sreesha; Faisal, Kunnathodi; Kumar, G Pradeep; Oommen, Oommen V; Akbarsha, Mohammad A

    2014-10-01

    Whereas in all other vertebrates the Müllerian ducts of genetic males are aborted during development, under the influence of Müllerian-inhibiting substance, in the caecilian amphibians they are retained as a pair of functional glands. It has long been speculated that the Müllerian gland might be the male accessory reproductive gland but there has been no direct evidence to this effect. The present study was undertaken to determine whether the caecilian Müllerian gland secretory proteins would bear antigenic similarity to secretory proteins of the prostate gland and/or the seminal vesicles of a mammal. The secretory proteins of the Müllerian gland of Ichthyophis tricolor were evaluated for cross-reactivity with antisera raised against rat ventral prostate and seminal vesicle secretory proteins, adopting SDS-PAGE, two-dimensional electrophoresis and immunoblot techniques. Indeed there was a cross-reaction of five Müllerian gland secretory protein fractions with prostatic protein antiserum and of three with seminal vesicle protein antiserum. A potential homology exists because in mammals the middle group of the prostate primordia is derived from a diverticulum of the Müllerian duct. Thus this study, by providing evidence for expression of prostatic and seminal vesicle proteins in the Müllerian gland, substantiates the point that in caecilians the Müllerian glands are the male accessory reproductive glands. PMID:25160003

  17. Male Age Affects Female Mate Preference, Quantity of Accessory Gland Proteins, and Sperm Traits and Female Fitness in D. melanogaster.

    PubMed

    Rezaei, Abolhasan; Krishna, Mysore Siddaiah; Santhosh, Hassan T

    2015-01-01

    For species in which mating is resource-independent and offspring do not receive parental care, theoretical models of age-based female mate preference predict that females should prefer to mate with older males as they have demonstrated ability to survive. Thus, females should obtain a fitness benefit from mating with older males. However, male aging is often associated with reductions in quantity of sperm. The adaptive significance of age-based mate choice is therefore unclear. Various hypotheses have made conflicting predictions concerning this issue, because published studies have not investigated the effect of age on accessory gland proteins and sperm traits. D. melanogaster exhibits resource-independent mating, and offspring do not receive parental care, making this an appropriate model for studying age-based mate choice. In the present study, we found that D. melanogaster females of all ages preferred to mate with the younger of two competing males. Young males performed significantly greater courtship attempts and females showed least rejection for the same than middle-aged and old males. Young males had small accessory glands that contained very few main cells that were larger than average. Nevertheless, compared with middle-aged or old males, the young males transferred greater quantities of accessory gland proteins and sperm to mated females. As a result, females that mated with young male produced more eggs and progeny than those that mated with older males. Furthermore, mating with young male reduced female's lifespan. These studies indicate that quantity of accessory gland proteins and sperm traits decreased with male age and females obtain direct fitness benefit from mating with preferred young males.

  18. Adaptive evolution of recently duplicated accessory gland protein genes in desert Drosophila.

    PubMed

    Wagstaff, Bradley J; Begun, David J

    2007-10-01

    The relationship between animal mating system variation and patterns of protein polymorphism and divergence is poorly understood. Drosophila provides an excellent system for addressing this issue, as there is abundant interspecific mating system variation. For example, compared to D. melanogaster subgroup species, repleta group species have higher remating rates, delayed sexual maturity, and several other interesting differences. We previously showed that accessory gland protein genes (Acp's) of Drosophila mojavensis and D. arizonae evolve more rapidly than Acp's in the D. melanogaster subgroup and that adaptive Acp protein evolution is likely more common in D. mojavensis/D. arizonae than in D. melanogaster/D. simulans. These findings are consistent with the idea that greater postcopulatory selection results in more adaptive evolution of seminal fluid proteins in the repleta group flies. Here we report another interesting evolutionary difference between the repleta group and the D. melanogaster subgroup Acp's. Acp gene duplications are present in D. melanogaster, but their high sequence divergence indicates that the fixation rate of duplicated Acp's has been low in this lineage. Here we report that D. mojavensis and D. arizonae genomes contain several very young duplicated Acp's and that these Acp's have experienced very rapid, adaptive protein divergence. We propose that rapid remating of female desert Drosophila generates selection for continuous diversification of the male Acp complement to improve male fertilization potential. Thus, mating system variation may be associated with adaptive protein divergence as well as with duplication of Acp's in Drosophila.

  19. Male accessory gland inflammation prevalence in type 2 diabetic patients with symptoms possibly reflecting autonomic neuropathy

    PubMed Central

    Condorelli, Rosita A; Vicari, Enzo; Calogero, Aldo E; La Vignera, Sandro

    2014-01-01

    Male accessory gland inflammation or infection (MAGI) is a potentially underdiagnosed complication of type 2 diabetes (DM2); specifically, we reported in a recent study that the frequency of MAGI was 43% among DM2 patients. In previous studies, we have demonstrated that diabetic autonomic neuropathy (DAN) is associated with a peculiar ultrasound characterization of the seminal vesicles (SVs) in DM2 patients. The aim of the present study was to evaluate the frequency of MAGI in two different categories of DM2 patients (i.e. patients with and without symptoms that possibly reflect DAN) and the respective ultrasound characterizations. Sixty DM2 patients with a mean (± s.e.m.) age of 42.0 ± 6.0 years (range: 34–47 years) were classified according to the presence or the absence of symptoms that could possibly reflect DAN (group A: DM2 with symptoms possibly reflecting DAN, n = 28 patients and group B: DM2 without symptoms possibly reflecting DAN, n = 32 patients). The patients in Group A exhibited a significantly higher frequency of MAGI compared with those in group B patients (P < 0.05); moreover, the Group A patients exhibited a significantly higher frequency of ultrasound signs suggestive of vesiculitis (P < 0.05). Finally, the concentrations of lymphocytes but not the concentrations of the leukocytes in the semen were significantly higher (P < 0.05) in group A compared with group B. PMID:24799635

  20. Epithelioid myoepithelioma of the accessory parotid gland: pathological and magnetic resonance imaging findings.

    PubMed

    Iguchi, Hiroyoshi; Yamada, Kei; Yamane, Hideo; Hashimoto, Shigeo

    2014-05-01

    Tumors of the accessory parotid gland (APG) are rare, and pleomorphic adenoma (PA) is the most common benign APG tumor subtype. Myoepithelioma of the APG is much rarer than PA, and to date, only 5 cases have been sporadically reported in the English literature. We describe the clinicopathological and MRI findings of an epithelioid myoepithelioma of the APG that was treated in our hospital. The patient's only clinical symptom was a slow-growing and painless mid-cheek mass. The tumor was suspected to be PA before surgery based on the following MRI findings: (1) a well-circumscribed and lobulated contour, (2) isointensity and hyperintensity relative to the muscle on T1- and T2-weighted images (WIs), respectively, (3) good enhancement on contrast-enhanced T1-WIs, (4) peripheral hypointensity on T2-WIs, and (5) a gradual time-signal intensity curve enhancement pattern on gadolinium-enhanced dynamic MRI. The tumor was completely resected via a standard parotidectomy approach, and the postoperative pathological examination of the tumor, including immunohistochemistry, confirmed the diagnosis of epithelioid myoepithelioma. As it is hardly possible to distinguish myoepithelioma from PA and low-grade malignant tumors preoperatively, a pathological examination using frozen sections is helpful for surgical strategy-related decisions.

  1. Comparative genomics of accessory gland protein genes in Drosophila melanogaster and D. pseudoobscura.

    PubMed

    Wagstaff, Bradley J; Begun, David J

    2005-04-01

    Male accessory gland protein genes (Acps) evolve rapidly in the melanogaster species subgroup of Drosophila. However, conservation of Acps in more diverged lineages is poorly understood. We used comparisons of the D. melanogaster and D. pseudoobscura genome sequences, along with empirical investigation of D. pseudoobscura transcription, to assay the D. pseudoobscura genome for orthologs of 13 D. melanogaster Acps (Acp26Aa, Acp26Ab, Acp29AB, Acp32CD, Acp33A, Acp36DE, Acp53Ea, Acp62F, Acp63F, Acp70A, Acp76A, Acp95EF, and Acp98AB). We find that Acp26Aa, Acp26Ab, Acp32CD, and Acp53Ea are present at the expected microsyntenic locations of D. pseudoobscura. Acp62F and Acp70A are also present, although they are located in nonsyntenic regions. For six of the remaining seven Acps, computational and molecular biological evidence suggests they are D. melanogaster orphans. The weighted average of interspecific amino acid identity for alignable residues across the six orthologous Acps is 35.6%. Population genetic data for D. pseudoobscura Acp26Aa show that this gene has been evolving under directional selection, as it has been in D. melanogaster/D. simulans. All four D. melanogaster Acps we analyze from chromosome arm 3L are absent from the homologous D. pseudoobscura XR chromosome arm, which was autosomal before an X chromosome-autosome fusion event in the D. pseudoobscura lineage. This observation is consistent with the hypothesis that male-advantage genes on the Drosophila X chromosome are disfavored by natural selection.

  2. Comparative genomics of Roseobacter clade bacteria isolated from the accessory nidamental gland of Euprymna scolopes

    PubMed Central

    Collins, Andrew J.; Fullmer, Matthew S.; Gogarten, Johann P.; Nyholm, Spencer V.

    2015-01-01

    The accessory nidamental gland (ANG) of the female Hawaiian bobtail squid, Euprymna scolopes, houses a consortium of bacteria including members of the Flavobacteriales, Rhizobiales, and Verrucomicrobia but is dominated by members of the Roseobacter clade (Rhodobacterales) within the Alphaproteobacteria. These bacteria are deposited into the jelly coat of the squid’s eggs, however, the function of the ANG and its bacterial symbionts has yet to be elucidated. In order to gain insight into this consortium and its potential role in host reproduction, we cultured 12 Rhodobacterales isolates from ANGs of sexually mature female squid and sequenced their genomes with Illumina sequencing technology. For taxonomic analyses, the ribosomal proteins of 79 genomes representing both roseobacters and non-roseobacters along with a separate MLSA analysis of 33 housekeeping genes from Roseobacter organisms placed all 12 isolates from the ANG within two groups of a single Roseobacter clade. Average nucelotide identity analysis suggests the ANG isolates represent three genera (Leisingera, Ruegeria, and Tateyamaria) comprised of seven putative species groups. All but one of the isolates contains a predicted Type VI secretion system, which has been shown to be important in secreting signaling and/or effector molecules in host–microbe associations and in bacteria–bacteria interactions. All sequenced genomes also show potential for secondary metabolite production, and are predicted to be involved with the production of acyl homoserine lactones (AHLs) and/or siderophores. An AHL bioassay confirmed AHL production in three tested isolates and from whole ANG homogenates. The dominant symbiont, Leisingera sp. ANG1, showed greater viability in iron-limiting conditions compared to other roseobacters, possibly due to higher levels of siderophore production. Future comparisons will try to elucidate novel metabolic pathways of the ANG symbionts to understand their putative role in host

  3. Variation in sperm displacement and its association with accessory gland protein loci in Drosophila melanogaster

    SciTech Connect

    Clark, A.G.; Prout, T.; Harshman, L.G.

    1995-01-01

    Genes that influence mating and/or fertilization success may be targets for strong natural selection. If females remate frequently relative to the duration of sperm storage and rate of sperm use, sperm displacement may be an important component of male reproductive success. Although it has long been known that mutant laboratory stocks of Drosophila differ in sperm displacement, the magnitude of the naturally occurring genetic variation in this character has not been systematically quantified. Here we report the results of a screen for variation in sperm displacement among 152 lines of Drosophila melanogaster that were made homozygous for second and/or third chromosomes recovered from natural populations. Sperm displacement was assayed by scoring the progeny of cn;bw females that had been mated sequentially to cn;bw and tested males in either order. Highly significant differences were seen in both the ability to displace sperm that is resident in the female`s reproductive tract and in the ability to resist displacement by subsequent sperm. Most lines exhibited nearly complete displacement, having nearly all progeny sired by the second male, but several lines had as few as half the progeny fathered by the second male. Lines that were identified in the screen for naturally occurring variation in sperm displacement were also characterized for single-strand conformation polymorphisms (SSCP) at seven accessory gland protein (Acp) genes. Significant associations were found between particular Acp alleles at four different loci (Acp26Aa/Ab, Acp29B, Acp36DE and Acp53E) and the ability of males to resist displacement by subsequent sperm. There was no correlation between the ability to displace resident sperm and the ability to resist being displaced by subsequent sperm. This lack of correlation, and the association of Acp alleles with resisting subsequent sperm only, suggests that different mechanisms mediate the two components of sperm displacement. 36 refs., 4 figs., 7 tabs.

  4. Acquired premature ejaculation and male accessory gland infection: relevance of ultrasound examination

    PubMed Central

    La Vignera, Sandro; Condorelli, Rosita A; Vicari, Enzo; Favilla, Vincenzo; Morgia, Giuseppe; Calogero, Aldo E

    2016-01-01

    We have previously demonstrated a high frequency of premature ejaculation (PE) among patients with male accessory gland infection (MAGI). The aim of this study was to evaluate the ultrasound (US) features of patients with MAGI and acquired premature ejaculation (APE) associated (MAGI-APEpos). US evaluation of 50 MAGI-APEpos patients compared to 50 patients with MAGI without PE (MAGI-PEneg) which represent the control group. The diagnosis of APE was made through the evaluation of Intravaginal ejaculation latency time (IELT) and confirmed with the questionnaire PEDT (Premature Ejaculation Diagnostic Tool). The main outcome measure was represented by the frequency of US criteria suggestive of P (prostatitis), V (vesiculitis), and E (epididymitis) in MAGI-APEpos and MAGI-PEneg patients. MAGI-APEpos patients showed a total number of US criteria significantly higher compared to MAGI-PEneg patients. MAGI-APEpos showed a higher frequency of US criteria of V and E (complicated forms of MAGI). Finally, in MAGI-APEpos group, it was found a positive relationship between the anteroposterior diameter (APD) of the caudal tract of the epididymis and the APD of the seminal vesicles, as well as between both diameters and the PEDT score. MAGI-APEpos patients have a peculiar US characterization compared to MAGI-PEneg patients. According to these results, US evaluation of the epididymal and of the prostato vesicular tract should be considered in the practical clinical approach of patients with MAGI and APE. In particular, it could be a support for a possible pathophysiological interpretation of this clinical problem in these patients. PMID:26387584

  5. Transcriptional Profiles of Mating-Responsive Genes from Testes and Male Accessory Glands of the Mediterranean Fruit Fly, Ceratitis capitata

    PubMed Central

    Scolari, Francesca; Gomulski, Ludvik M.; Ribeiro, José M. C.; Siciliano, Paolo; Meraldi, Alice; Falchetto, Marco; Bonomi, Angelica; Manni, Mosè; Gabrieli, Paolo; Malovini, Alberto; Bellazzi, Riccardo; Aksoy, Serap; Gasperi, Giuliano; Malacrida, Anna R.

    2012-01-01

    Background Insect seminal fluid is a complex mixture of proteins, carbohydrates and lipids, produced in the male reproductive tract. This seminal fluid is transferred together with the spermatozoa during mating and induces post-mating changes in the female. Molecular characterization of seminal fluid proteins in the Mediterranean fruit fly, Ceratitis capitata, is limited, although studies suggest that some of these proteins are biologically active. Methodology/Principal Findings We report on the functional annotation of 5914 high quality expressed sequence tags (ESTs) from the testes and male accessory glands, to identify transcripts encoding putative secreted peptides that might elicit post-mating responses in females. The ESTs were assembled into 3344 contigs, of which over 33% produced no hits against the nr database, and thus may represent novel or rapidly evolving sequences. Extraction of the coding sequences resulted in a total of 3371 putative peptides. The annotated dataset is available as a hyperlinked spreadsheet. Four hundred peptides were identified with putative secretory activity, including odorant binding proteins, protease inhibitor domain-containing peptides, antigen 5 proteins, mucins, and immunity-related sequences. Quantitative RT-PCR-based analyses of a subset of putative secretory protein-encoding transcripts from accessory glands indicated changes in their abundance after one or more copulations when compared to virgin males of the same age. These changes in abundance, particularly evident after the third mating, may be related to the requirement to replenish proteins to be transferred to the female. Conclusions/Significance We have developed the first large-scale dataset for novel studies on functions and processes associated with the reproductive biology of Ceratitis capitata. The identified genes may help study genome evolution, in light of the high adaptive potential of the medfly. In addition, studies of male recovery dynamics in terms

  6. Lead accumulation, oxidative damage and histopathological alteration in testes and accessory glands of freshwater crab, Sinopotamon henanense, induced by acute lead exposure.

    PubMed

    Li, Na; Hou, Yu-hua; Ma, Dan-dan; Jing, Wei-xin; Dahms, Hans-Uwe; Wang, Lan

    2015-07-01

    Lead (Pb) is one of the most toxic environmental pollutants and known to exert multiple toxic effects including gonadotoxic and spermiotoxic effects. In order to understand toxic mechanisms of lead (Pb) on the testes and the accessory glands of crabs, we investigated Pb accumulation in testes and accessory glands and the survival rate of sperms of freshwater crab, Sinopotamon henanense. The tissue damaging effects of Pb was also investigated by histopathological examination and analyses of antioxidant enzymes as well as lipid peroxidation. Crabs were exposed to different Pb concentrations (0, 3.675, 7.35, 14.7, 29.4 and 58.8 mg/L) for 3, 5 and 7 days. The results showed that Pb levels in testes and accessory glands increased significantly following Pb exposure for 5 and 7 days in almost all treated groups, and survival rate of sperm decreased with increasing Pb concentrations at 5 and 7 days. Morphological changes identified histologically were discovered in testes, including a disordered arrangement of germ cells, a decreased number of sperm in the lumina of the seminiferous tubules, extensive necrosis in the germinal layer of the seminiferous tubules, etc. At the same time, histological abnormalities were discovered in accessory glands, the wall cells were separated from the basement membrane, and wall cells were missing partly. The activities of SOD, GPx and CAT in testes showed no statistically significant changes compared to the control for 3 days, and initially increased and subsequently decreased with increasing Pb concentrations at 5 and 7 days. The antioxidant enzyme activities in accessory glands initially increased and subsequently decreased with increasing Pb concentrations and Pb exposure. This was accompanied with an increase in malondialdehyde (MDA) content in a concentration-dependent manner. These results showed that acute Pb exposure led to a reduction of survival rate of sperm and harmful effects at the cellular level of crab testes and accessory

  7. Protein and Peptide Composition of Male Accessory Glands of Apis mellifera Drones Investigated by Mass Spectrometry.

    PubMed

    Gorshkov, Vladimir; Blenau, Wolfgang; Koeniger, Gudrun; Römpp, Andreas; Vilcinskas, Andreas; Spengler, Bernhard

    2015-01-01

    In honeybees, reproductive females usually mate early in their life with more than 10 males in free flight, often within 10 minutes, and then store male gametes for up to five years. Because of the extreme polyandry and mating in free flight special adaptations in males are most likely. We present here the results of an investigation of the protein content of four types of male reproductive glands from the Western honeybee (Apis mellifera) drone, namely seminal vesicles (secretion in ejaculate), as well as bulbus, cornua and mucus glands (secretions for the mating plug). Using high resolution and accuracy mass spectrometry and a combination of database searching and de novo sequencing techniques it was possible to identify 50 different proteins in total, inside all mentioned glands, except in the mucus gland. Most of the proteins are unique for a specific gland type, only one of them (H9KEY1/ATP synthase subunit O) was found in three glands, and 7 proteins were found in two types of glands. The identified proteins represent a wide variety of biological functions and can be assigned to several physiological classes, such as protection, energy generation, maintaining optimal conditions, associated mainly with vesicula seminalis; signaling, cuticle proteins, icarpin and apolipoproteins located mainly in the bulbus and cornua glands; and some other classes. Most of the discovered proteins were not found earlier during investigation of semen, seminal fluid and tissue of reproductive glands of the bee drone. Moreover, we provide here the origin of each protein. Thus, the presented data might shed light on the role of each reproductive gland.

  8. Protein and Peptide Composition of Male Accessory Glands of Apis mellifera Drones Investigated by Mass Spectrometry

    PubMed Central

    Gorshkov, Vladimir; Blenau, Wolfgang; Koeniger, Gudrun; Römpp, Andreas; Vilcinskas, Andreas; Spengler, Bernhard

    2015-01-01

    In honeybees, reproductive females usually mate early in their life with more than 10 males in free flight, often within 10 minutes, and then store male gametes for up to five years. Because of the extreme polyandry and mating in free flight special adaptations in males are most likely. We present here the results of an investigation of the protein content of four types of male reproductive glands from the Western honeybee (Apis mellifera) drone, namely seminal vesicles (secretion in ejaculate), as well as bulbus, cornua and mucus glands (secretions for the mating plug). Using high resolution and accuracy mass spectrometry and a combination of database searching and de novo sequencing techniques it was possible to identify 50 different proteins in total, inside all mentioned glands, except in the mucus gland. Most of the proteins are unique for a specific gland type, only one of them (H9KEY1/ATP synthase subunit O) was found in three glands, and 7 proteins were found in two types of glands. The identified proteins represent a wide variety of biological functions and can be assigned to several physiological classes, such as protection, energy generation, maintaining optimal conditions, associated mainly with vesicula seminalis; signaling, cuticle proteins, icarpin and apolipoproteins located mainly in the bulbus and cornua glands; and some other classes. Most of the discovered proteins were not found earlier during investigation of semen, seminal fluid and tissue of reproductive glands of the bee drone. Moreover, we provide here the origin of each protein. Thus, the presented data might shed light on the role of each reproductive gland. PMID:25955586

  9. Protein and Peptide Composition of Male Accessory Glands of Apis mellifera Drones Investigated by Mass Spectrometry.

    PubMed

    Gorshkov, Vladimir; Blenau, Wolfgang; Koeniger, Gudrun; Römpp, Andreas; Vilcinskas, Andreas; Spengler, Bernhard

    2015-01-01

    In honeybees, reproductive females usually mate early in their life with more than 10 males in free flight, often within 10 minutes, and then store male gametes for up to five years. Because of the extreme polyandry and mating in free flight special adaptations in males are most likely. We present here the results of an investigation of the protein content of four types of male reproductive glands from the Western honeybee (Apis mellifera) drone, namely seminal vesicles (secretion in ejaculate), as well as bulbus, cornua and mucus glands (secretions for the mating plug). Using high resolution and accuracy mass spectrometry and a combination of database searching and de novo sequencing techniques it was possible to identify 50 different proteins in total, inside all mentioned glands, except in the mucus gland. Most of the proteins are unique for a specific gland type, only one of them (H9KEY1/ATP synthase subunit O) was found in three glands, and 7 proteins were found in two types of glands. The identified proteins represent a wide variety of biological functions and can be assigned to several physiological classes, such as protection, energy generation, maintaining optimal conditions, associated mainly with vesicula seminalis; signaling, cuticle proteins, icarpin and apolipoproteins located mainly in the bulbus and cornua glands; and some other classes. Most of the discovered proteins were not found earlier during investigation of semen, seminal fluid and tissue of reproductive glands of the bee drone. Moreover, we provide here the origin of each protein. Thus, the presented data might shed light on the role of each reproductive gland. PMID:25955586

  10. [Polymorphous low-grade adenocarcinoma of the accessory salivary glands--a case report].

    PubMed

    Chadli-Debbiche, A; Ben Brahim, E; Dougaz, A; Mansouri, D; Fraoua-Abdelmoula, F; Mbarek, A; Mamouri, M; Mzabi-Regaya, S

    2000-10-01

    A case of polymorphous low-grade adenocarcinoma of minor salivary gland is reported. This tumor was first described in two clinical case series in 1983. Before that time most of these neoplasms were diagnosed as benign salivary gland neoplasms (pleomorphic adenomas) or salivary malignant conditions (malignant pleomorphic adenomas, adenoid cystic carcinomas, papillary adenocarcinomas and adenocarcinoma not otherwise stated). This neoplasm, with few exceptions, originates in minor salivary gland tissues of the palates or buccal mucosa. It is characteristically slow to enlarge. Clinical reports show the neoplasm present for many years before diagnosis. The tumor have a variety of morphological patterns, a cytological uniformity and an infiltration into adjacent structures. The treatment is a wide local excision. Recurrences and lymph node metastases are rare.

  11. Induction of a heparin-stimulated serine proteinase in sex accessory gland tumors of the Lobund-Wistar rat.

    PubMed

    Wilson, Michael J; Lind, Jeremy; Sinha, Akhouri A

    2015-08-01

    Induction of new proteinase activities that may process growth factors, modify cell surface receptors, cleave extracellular matrix proteins, etc. is considered fundamental in carcinogenesis. The purpose of this study was to characterize a novel proteinase activity induced in sex accessory gland cancers (about 70% in seminal vesicles) of adult male Lobund-Wistar rats by a single injection of N-nitroso-N-methylurea (NMU; 25mg/kg) followed by implanted testosterone propionate (45mg in silastic tubing every 2months) treatment for 10-14months. A 28kDa proteinase activity was detected in tumor extracts using SDS-gelatin gel zymography with incubations done without CaCl2. Its activity was stimulated 15 fold by heparin (optimal activity 1.5-3.0μg/lane) added to the tissue extract-SDS sample buffer prior to electrophoresis. No 28kDa heparin-stimulated proteinase (H-SP) was found in the dorsal, lateral and anterior (coagulating gland) prostate lobes or seminal vesicles of untreated adult rats, but there was a 26-30kDa Ca(2+)-independent proteinase activity in the ventral prostate that showed limited heparin stimulation. The 28kDa H-SP was completely inhibited by 1.0mM 4-(2-aminoethyl)benzenesulfonylfluoride (AESBF) indicating that it was a serine-type proteinase. Other types of proteinase inhibitors were without effect, including serine proteinase inhibitors benzamidine, tranexamic acid and ε-aminocaproic acid. Proteinase activities of about 28kDa were found with casein, fibrinogen or carboxymethylated transferrin as substrate, however, these activities were not stimulated by heparin. Similar levels of activities of the 28kDa H-SP were found in primary tumors and their metastases, but little/no activity was detected in serum, even from rats with large tumor volume and metastases. These data demonstrate overexpression of a heparin-stimulated 28kDa serine proteinase in the primary tumors of sex accessory gland cancers and their metastases. This proteinase either does not

  12. A Syringe-Like Love Dart Injects Male Accessory Gland Products in a Tropical Hermaphrodite

    PubMed Central

    Koene, Joris M.; Liew, Thor-Seng; Montagne-Wajer, Kora; Schilthuizen, Menno

    2013-01-01

    Sexual conflict shapes the evolution of many behaviours and processes involved in reproduction. Nearly all evidence supporting this comes from species where the sexes are separated. However, a substantial proportion of animals and most plants are hermaphroditic, and theoretical work predicts that sexual conflict plays an important role even when the sexes are joined within one individual. This seems to have resulted in bizarre mating systems, sophisticated sperm packaging and complex reproductive morphologies. By far the best-known example of such a strategy in hermaphrodites is the shooting of so-called love-darts in land snails. All known love darts carry a gland product on their outside and enter this into the partner’s hemolymph by stabbing. Here, we show that species of the snail genus Everettia possess a syringe-like dart that serves as a real injection needle. Their dart is round in cross-section, contains numerous channels, and has perforations along its side. Histology and electron microscopy show that these holes connect to the channels inside the dart and run all the way up to the elaborate mucus glands that are attached to the dart sac. This is the first report on a love dart that is used as a syringe to directly inject the gland product into the partner’s hemolymph. Although the exact use and function of this dart remains to be demonstrated, this clearly adds to the complexity of the evolution of reproductive strategies in hermaphrodites in general. Moreover, the perforations on the outside of the love dart resemble features of other injection devices, thus uncovering common design and repeated evolution of such features in animals. PMID:23894565

  13. A syringe-like love dart injects male accessory gland products in a tropical hermaphrodite.

    PubMed

    Koene, Joris M; Liew, Thor-Seng; Montagne-Wajer, Kora; Schilthuizen, Menno

    2013-01-01

    Sexual conflict shapes the evolution of many behaviours and processes involved in reproduction. Nearly all evidence supporting this comes from species where the sexes are separated. However, a substantial proportion of animals and most plants are hermaphroditic, and theoretical work predicts that sexual conflict plays an important role even when the sexes are joined within one individual. This seems to have resulted in bizarre mating systems, sophisticated sperm packaging and complex reproductive morphologies. By far the best-known example of such a strategy in hermaphrodites is the shooting of so-called love-darts in land snails. All known love darts carry a gland product on their outside and enter this into the partner's hemolymph by stabbing. Here, we show that species of the snail genus Everettia possess a syringe-like dart that serves as a real injection needle. Their dart is round in cross-section, contains numerous channels, and has perforations along its side. Histology and electron microscopy show that these holes connect to the channels inside the dart and run all the way up to the elaborate mucus glands that are attached to the dart sac. This is the first report on a love dart that is used as a syringe to directly inject the gland product into the partner's hemolymph. Although the exact use and function of this dart remains to be demonstrated, this clearly adds to the complexity of the evolution of reproductive strategies in hermaphrodites in general. Moreover, the perforations on the outside of the love dart resemble features of other injection devices, thus uncovering common design and repeated evolution of such features in animals.

  14. The “Vampirome”: Transcriptome and proteome analysis of the principal and accessory submaxillary glands of the vampire bat Desmodus rotundus, a vector of human rabies

    PubMed Central

    Francischetti, Ivo M. B.; Assumpção, Teresa C. F.; Ma, Dongying; Li, Yuan; Vicente, Eliane C.; Uieda, Wilson; Ribeiro, José M.C.

    2013-01-01

    Vampire bats are notorious for being the sole mammals that strictly feed on fresh blood for their survival. While their saliva has been historically associated with anticoagulants, only one antihemostatic (plasminogen activator) has been molecularly and functionally characterized. Here, RNAs from both principal submandibular and accessory glands of Desmodus rotundus were extracted, and ~ 200 million reads were sequenced by Illumina. The principal gland was enriched with plasminogen activators with fibrinolytic properties, members of lipocalin and secretoglobin families, which bind prohemostatic prostaglandins, and endonucleases, which cleave neutrophil-derived procoagulant NETs. Anticoagulant (tissue factor pathway inhibitor, TFPI), vasodilators (PACAP and C-natriuretic peptide), and metalloproteases (ADAMTS-1) were also abundantly expressed. Members of the TSG-6 (anti-inflammatory), antigen 5/CRISP, and CCL28-like (antimicrobial) protein families were also sequenced. Apyrases (which remove platelet agonist ADP), phosphatases (which degrade procoagulant polyphosphates), and sphingomyelinase were found at lower transcriptional levels. Accessory glands were enriched with antimicrobials (lysozyme, defensin, lactotransferrin) and protease inhibitors (TIL-domain, cystatin, Kazal). Mucins, heme-oxygenase, and IgG chains were present in both glands. Proteome analysis by nano LC-MS/MS confirmed that several transcripts are expressed in the glands. The database presented herein is accessible online at http://exon.niaid.nih.gov/transcriptome/D_rotundus/Supplemental-web.xlsx. These results reveal that bat saliva emerges as a novel source of modulators of vascular biology. PMID:23411029

  15. Oxytocin administration before sperm collection by transrectal ultrasonic-guided massage of the accessory sex glands in mouflons and bucks.

    PubMed

    Ungerfeld, Rodolfo; Abril-Sánchez, Silvia; Toledano-Díaz, Adolfo; Beracochea, Florencia; Castaño, Cristina; Giriboni, Julia; Santiago-Moreno, Julián

    2016-10-01

    Transrectal ultrasonic-guided massage of the accessory sex glands (TUMASG) is an alternative technique for sperm collection which decreases negative animal welfare concerns of electroejaculation. However, quality of collected sperm with TUMASG is less than that collected by electroejaculation. Utilisation of TUMASG may not, however, induce strong muscular contractions, so administration of oxytocin before the procedure may improve sperm quality. Therefore, two studies were designed to determine if administration of oxytocin before TUMASG improves the procedure and quality of the collected semen. The first study was performed with anaesthetised mouflons, and the second with non-anaesthetised Gabon bucks. Time length, number of electric pulses applied and numbers of vocalizations were recorded, and sperm characteristics were analysed. The number of electrical pulses and sperm characteristics did not differ with oxytocin administration in mouflons. However, oxytocin administration decreased time length (P=0.02) and tended to decrease the number of electric pulses needed for induction of ejaculation (P=0.08) in bucks. The number of vocalizations and sperm variables did not differ when the two procedures were used. In conclusion, oxytocin administration before TUMASG shortened the procedure and tended to decrease the number of electrical pulses needed to induce ejaculation in conscious bucks, thus, decreasing welfare concerns for the animals in which TUMASG is used. Therefore, its routine inclusion in this species should be considered. PMID:27530370

  16. Function and composition of male accessory gland secretions in Anopheles gambiae: a comparison with other insect vectors of infectious diseases

    PubMed Central

    Baldini, Francesco; Gabrieli, Paolo; Rogers, David W.; Catteruccia, Flaminia

    2012-01-01

    Human malaria, a major public health burden in tropical and subtropical countries, is transmitted exclusively by the bite of a female Anopheles mosquito. Malaria control strategies aimed at inducing sexual sterility in natural vector populations are an attractive alternative to the use of insecticides. However, despite their importance as disease vectors, limited information is available on the molecular mechanisms regulating fertility in Anopheles mosquitoes. In the major malaria vector, An. gambiae, the full complement of sperm and seminal fluid required for a female’s lifelong egg production is obtained from a single mating event. This single mating has important consequences for the physiology and behavior of An. gambiae females: in particular, they become refractory to further insemination, and they start laying eggs. In other insects including Drosophila, similar post-copulatory changes are induced by seminal proteins secreted by the male accessory glands and transferred to the female during mating. In this review, we analyze the current state of knowledge on the function and characterization of male seminal proteins in An. gambiae, and provide a comparative assessment of the role of these male reproductive factors in other mosquito vectors of human disease in which female post-copulatory behavior has been studied. Knowledge of the factors and mechanisms regulating fertility in An. gambiae and other vectors can help the design of novel control strategies to fight the spread of disease. PMID:22943543

  17. Oxytocin administration before sperm collection by transrectal ultrasonic-guided massage of the accessory sex glands in mouflons and bucks.

    PubMed

    Ungerfeld, Rodolfo; Abril-Sánchez, Silvia; Toledano-Díaz, Adolfo; Beracochea, Florencia; Castaño, Cristina; Giriboni, Julia; Santiago-Moreno, Julián

    2016-10-01

    Transrectal ultrasonic-guided massage of the accessory sex glands (TUMASG) is an alternative technique for sperm collection which decreases negative animal welfare concerns of electroejaculation. However, quality of collected sperm with TUMASG is less than that collected by electroejaculation. Utilisation of TUMASG may not, however, induce strong muscular contractions, so administration of oxytocin before the procedure may improve sperm quality. Therefore, two studies were designed to determine if administration of oxytocin before TUMASG improves the procedure and quality of the collected semen. The first study was performed with anaesthetised mouflons, and the second with non-anaesthetised Gabon bucks. Time length, number of electric pulses applied and numbers of vocalizations were recorded, and sperm characteristics were analysed. The number of electrical pulses and sperm characteristics did not differ with oxytocin administration in mouflons. However, oxytocin administration decreased time length (P=0.02) and tended to decrease the number of electric pulses needed for induction of ejaculation (P=0.08) in bucks. The number of vocalizations and sperm variables did not differ when the two procedures were used. In conclusion, oxytocin administration before TUMASG shortened the procedure and tended to decrease the number of electrical pulses needed to induce ejaculation in conscious bucks, thus, decreasing welfare concerns for the animals in which TUMASG is used. Therefore, its routine inclusion in this species should be considered.

  18. Male Accessory Gland Protein Reduces Egg Laying in a Simultaneous Hermaphrodite

    PubMed Central

    Koene, Joris M.; Sloot, Wiebe; Montagne-Wajer, Kora; Cummins, Scott F.; Degnan, Bernard M.; Smith, John S.; Nagle, Gregg T.; ter Maat, Andries

    2010-01-01

    Seminal fluid is an important part of the ejaculate of internally fertilizing animals. This fluid contains substances that nourish and activate sperm for successful fertilization. Additionally, it contains components that influence female physiology to further enhance fertilization success of the sperm donor, possibly beyond the recipient's optimum. Although evidence for such substances abounds, few studies have unraveled their identities, and focus has been exclusively on separate-sex species. We present the first detailed study into the seminal fluid composition of a hermaphrodite (Lymnaea stagnalis). Eight novel peptides and proteins were identified from the seminal-fluid-producing prostate gland and tested for effects on oviposition, hatching and consumption. The gene for the protein found to suppress egg mass production, Ovipostatin, was sequenced, thereby providing the first fully-characterized seminal fluid substance in a simultaneous hermaphrodite. Thus, seminal fluid peptides and proteins have evolved and can play a crucial role in sexual selection even when the sexes are combined. PMID:20404934

  19. A novel function for the Hox gene Abd-B in the male accessory gland regulates the long-term female post-mating response in Drosophila.

    PubMed

    Gligorov, Dragan; Sitnik, Jessica L; Maeda, Robert K; Wolfner, Mariana F; Karch, François

    2013-03-01

    In insects, products of the male reproductive tract are essential for initiating and maintaining the female post-mating response (PMR). The PMR includes changes in egg laying, receptivity to courting males, and sperm storage. In Drosophila, previous studies have determined that the main cells of the male accessory gland produce some of the products required for these processes. However, nothing was known about the contribution of the gland's other secretory cell type, the secondary cells. In the course of investigating the late functions of the homeotic gene, Abdominal-B (Abd-B), we discovered that Abd-B is specifically expressed in the secondary cells of the Drosophila male accessory gland. Using an Abd-B BAC reporter coupled with a collection of genetic deletions, we discovered an enhancer from the iab-6 regulatory domain that is responsible for Abd-B expression in these cells and that apparently works independently from the segmentally regulated chromatin domains of the bithorax complex. Removal of this enhancer results in visible morphological defects in the secondary cells. We determined that mates of iab-6 mutant males show defects in long-term egg laying and suppression of receptivity, and that products of the secondary cells are influential during sperm competition. Many of these phenotypes seem to be caused by a defect in the storage and gradual release of sex peptide in female mates of iab-6 mutant males. We also found that Abd-B expression in the secondary cells contributes to glycosylation of at least three accessory gland proteins: ovulin (Acp26Aa), CG1656, and CG1652. Our results demonstrate that long-term post-mating changes observed in mated females are not solely induced by main cell secretions, as previously believed, but that secondary cells also play an important role in male fertility by extending the female PMR. Overall, these discoveries provide new insights into how these two cell types cooperate to produce and maintain a robust female PMR.

  20. Comparative Transcriptome Analysis of the Accessory Sex Gland and Testis from the Chinese Mitten Crab (Eriocheir sinensis)

    PubMed Central

    He, Lin; Jiang, Hui; Cao, Dandan; Liu, Lihua; Hu, Songnian; Wang, Qun

    2013-01-01

    The accessory sex gland (ASG) is an important component of the male reproductive system, which functions to enhance the fertility of spermatozoa during male reproduction. Certain proteins secreted by the ASG are known to bind to the spermatozoa membrane and affect its function. The ASG gene expression profile in Chinese mitten crab (Eriocheir sinensis) has not been extensively studied, and limited genetic research has been conducted on this species. The advent of high-throughput sequencing technologies enables the generation of genomic resources within a short period of time and at minimal cost. In the present study, we performed de novo transcriptome sequencing to produce a comprehensive transcript dataset for the ASG of E. sinensis using Illumina sequencing technology. This analysis yielded a total of 33,221,284 sequencing reads, including 2.6 Gb of total nucleotides. Reads were assembled into 85,913 contigs (average 218 bp), or 58,567 scaffold sequences (average 292 bp), that identified 37,955 unigenes (average 385 bp). We assembled all unigenes and compared them with the published testis transcriptome from E. sinensis. In order to identify which genes may be involved in ASG function, as it pertains to modification of spermatozoa, we compared the ASG and testis transcriptome of E. sinensis. Our analysis identified specific genes with both higher and lower tissue expression levels in the two tissues, and the functions of these genes were analyzed to elucidate their potential roles during maturation of spermatozoa. Availability of detailed transcriptome data from ASG and testis in E. sinensis can assist our understanding of the molecular mechanisms involved with spermatozoa conservation, transport, maturation and capacitation and potentially acrosome activation. PMID:23342039

  1. Innervation of vas deferens and accessory male genital glands in the water buffalo (Bubalus bubalis). Neurochemical characteristics and relationships to the reproductive activity.

    PubMed

    Mirabella, Nicola; Squillacioti, Caterina; Varricchio, Ettore; Genovese, Angelo; Paino, Giuseppe

    2003-05-01

    Autonomic nerves supplying mammalian male internal genital organs have an important role in the regulation of reproductive function. To find out the relationships between the neurochemical content of these nerves and the reproductive activity, we performed a histochemical and immunohistochemical study in a species, the water buffalo, exhibiting a seasonal sexual behaviour. The distribution of noradrenergic and nitric oxide synthase (NOS)- and peptide-containing nerves was evaluated during the mating and non-mating periods. Fresh segments of vas deferens and accessory genital glands were collected immediately after slaughter and immersed in 4% paraformaldehyde. Frozen sections were obtained and processed according to single and double labelling immunofluorescent procedures or NADPH-diaphorase histochemistry. During the mating period, a dense noradrenergic innervation was observed to supply the vas deferens as well as the accessory genital glands. NOS- and peptide-containing nerves were also observed but with a lower density. During the non-mating period noradrenergic nerves dramatically reduced. In addition, neuropeptide Y (NPY)- and vasoactive intestinal peptide (VIP)-containing nerves were also reduced. These findings suggest the presence of complex interactions between androgen hormones and the autonomic nerve supply in the regulation of male water buffalo reproductive functions.

  2. Synthesis, depletion and cell-type expression of a protein from the male accessory glands of the dengue vector mosquito Aedes aegypti.

    PubMed

    Alfonso-Parra, Catalina; Avila, Frank W; Deewatthanawong, Prasit; Sirot, Laura K; Wolfner, Mariana F; Harrington, Laura C

    2014-11-01

    Aedes aegypti males transfer sperm and seminal fluid proteins (Sfps), primarily produced by male accessory glands (AGs), to females during mating. When collectively injected or transplanted into females, AG tissues and/or seminal fluid homogenates have profound effects on Aedes female physiology and behavior. To identify targets and design new strategies for vector control, it is important to understand the biology of the AGs. Thus, we examined characteristics of AG secretion and development in A. aegypti, using the AG-specific seminal fluid protein, AAEL010824, as a marker. We showed that AAEL010824 is first detectable by 12h post-eclosion, and increases in amount over the first 3 days of adult life. We then showed that the amount of AAEL0010824 in the AG decreases after mating, with each successive mating depleting it further; by 5 successive matings with no time for recovery, its levels are very low. AAEL010824 levels in a depleted male are replenished by 48 h post-mating. In addition to examining the level of AAEL010824 protein, we also characterized the expression of its gene. We did this by making a transgenic mosquito line that carries an Enhanced Green Fluorescence Protein (EGFP) fused to the AAEL0010824 promoter that we defined here. We showed that AAEL010824 is expressed in the anterior cells of the accessory glands, and that its RNA levels also respond to mating. In addition to further characterizing AAEL010824 expression, our results with the EGFP fusion provide a promoter for driving AG expression. By providing this information on the biology of an important male reproductive tissue and the production of one of its seminal proteins, our results lay the foundation for future work aimed at identifying novel targets for mosquito population control.

  3. The Female Post-Mating Response Requires Genes Expressed in the Secondary Cells of the Male Accessory Gland in Drosophila melanogaster.

    PubMed

    Sitnik, Jessica L; Gligorov, Dragan; Maeda, Robert K; Karch, François; Wolfner, Mariana F

    2016-03-01

    Seminal proteins from the Drosophila male accessory gland induce post-mating responses (PMR) in females. The PMR comprise behavioral and physiological changes that include increased egg laying, decreased receptivity to courting males, and changes in the storage and use of sperm. Many of these changes are induced by a "sex peptide" (SP) and are maintained by SP's binding to, and slow release from, sperm. The accessory gland contains two secretory cell types with distinct morphological and developmental characteristics. Products of these "main" and "secondary" cells work interdependently to induce and maintain the PMR. To identify individual genes needed for the morphology and function of secondary cells, we studied iab-6(cocu) males, whose secondary cells have abnormal morphology and fail to provide products to maintain the PMR. By RNA-seq, we identified 77 genes that are downregulated by a factor of >5× in iab-6(cocu) males. By functional assays and microscopy, we tested 20 candidate genes and found that at least 9 are required for normal storage and release of SP in mated females. Knockdown of each of these 9 genes consequently leads to a reduction in egg laying and an increase in receptivity over time, confirming a role for the secondary cells in maintaining the long-term PMR. Interestingly, only 1 of the 9 genes, CG3349, encodes a previously reported seminal fluid protein (Sfp), suggesting that secondary cells may perform essential functions beyond the production and modification of known Sfps. At least 3 of the 9 genes also regulate the size and/or abundance of secondary cell vacuoles, suggesting that the vacuoles' contents may be important for the machinery used to maintain the PMR. PMID:26746709

  4. Pleomorphic adenoma of the accessory parotid gland: case report and reappraisal of intraoral extracapsular dissection for management.

    PubMed

    Tsegga, Tibebu M; Britt, Jennifer D; Ellwanger, Aragon R

    2015-03-01

    Pleomorphic adenoma is the most common tumor of the major and minor salivary glands. Rarely is it found evolving from an ectopic location of major salivary glandular tissue in the mid cheek. A healthy 56-year-old woman presented to our institution with a 20-year duration of a slowly growing right cheek soft tissue mass that was causing facial asymmetry. No significant functional or neurosensory dysfunction was appreciated. Radiologic examination showed a heterogeneous, hyperintense, well-delineated mass within the region of the right buccal fat pad. Fine-needle aspiration biopsy showed benign salivary gland elements consistent with pleomorphic adenoma. The decision was made to perform intraoral extracapsular dissection for removal. Discussion of the clinical assessment and magnetic resonance imaging evaluation with an emphasis on intraoral extracapsular dissection for definitive surgical therapy of longstanding benign salivary gland tumors is emphasized.

  5. Morphophysiology and ultrastructure of the male reproductive accessory glands of the bats Carollia perspicillata, Glossophaga soricina and Phyllostomus discolor (Chiroptera: Phyllostomidae).

    PubMed

    Martins, Fabiane F; Beguelini, Mateus R; Puga, Cintia C I; Morielle-Versute, Eliana; Vilamaior, Patricia S L; Taboga, Sebastião R

    2016-07-01

    The male reproductive accessory glands (RAGs) are important organs that contribute to the secretion of different substances that composed the ejaculate. Despite this important function, their composition, anatomy and function vary widely between species. Thus, the RAGs of three species of phyllostomid bats were morphologically and ultrastructurally characterized and compared in this study. The RAGs of the three analyzed species are composed of a prostate and a pair of bulbourethral glands (BG). In all species, the prostate is composed of three well-defined regions (ventral, dorsolateral and dorsal regions). The ventral region showed an atypical epithelium (undefined) with no obvious cellular limits and a holocrine PAS-positive secretion. The dorsolateral region of Carollia perspicillata and Phyllostomus discolor showed a pseudostratified cubic morphology, and that from Glossophaga soricina had a columnar morphology endowed with cytoplasmic projections and stereocilia. The dorsal region of the three analyzed species is composed of a pseudostratified columnar epithelium endowed with stereocilia; however, G. soricina also presented cytoplasmic projections in the apical portions of the secretory cells similar to those in the dorsolateral region. The BG of the three analyzed species are composed of a pseudostratified columnar epithelium including basal and PAS-positive secretory cells. In conclusion, this study morphologically and ultrastructurally characterized the RAGs of three species of phyllostomid bats, demonstrating the presence of a novel third prostatic region in species of this family. The results also showed the absence of seminal vesicles and ampullary glands, and better characterized the holocrine pattern of the prostatic ventral region, which is unique to bats.

  6. Morphophysiology and ultrastructure of the male reproductive accessory glands of the bats Carollia perspicillata, Glossophaga soricina and Phyllostomus discolor (Chiroptera: Phyllostomidae).

    PubMed

    Martins, Fabiane F; Beguelini, Mateus R; Puga, Cintia C I; Morielle-Versute, Eliana; Vilamaior, Patricia S L; Taboga, Sebastião R

    2016-07-01

    The male reproductive accessory glands (RAGs) are important organs that contribute to the secretion of different substances that composed the ejaculate. Despite this important function, their composition, anatomy and function vary widely between species. Thus, the RAGs of three species of phyllostomid bats were morphologically and ultrastructurally characterized and compared in this study. The RAGs of the three analyzed species are composed of a prostate and a pair of bulbourethral glands (BG). In all species, the prostate is composed of three well-defined regions (ventral, dorsolateral and dorsal regions). The ventral region showed an atypical epithelium (undefined) with no obvious cellular limits and a holocrine PAS-positive secretion. The dorsolateral region of Carollia perspicillata and Phyllostomus discolor showed a pseudostratified cubic morphology, and that from Glossophaga soricina had a columnar morphology endowed with cytoplasmic projections and stereocilia. The dorsal region of the three analyzed species is composed of a pseudostratified columnar epithelium endowed with stereocilia; however, G. soricina also presented cytoplasmic projections in the apical portions of the secretory cells similar to those in the dorsolateral region. The BG of the three analyzed species are composed of a pseudostratified columnar epithelium including basal and PAS-positive secretory cells. In conclusion, this study morphologically and ultrastructurally characterized the RAGs of three species of phyllostomid bats, demonstrating the presence of a novel third prostatic region in species of this family. The results also showed the absence of seminal vesicles and ampullary glands, and better characterized the holocrine pattern of the prostatic ventral region, which is unique to bats. PMID:27425652

  7. Effect of semen collection by transrectal massage of accessory sexual glands or artificial vagina on the outcome of breeding soundness examinations of Italian yearling beef bulls.

    PubMed

    Sylla, Lakamy; Palombi, Claudio; Stradaioli, Giuseppe; Vagniluca, Antonio; Monaci, Maurizio

    2015-03-15

    Although semen quality is one of the major traits that influence breeding soundness examination outcomes in bulls, field conditions occasionally do not allow for the collection of semen samples by means of an artificial vagina. The aims of the present study were to report the results of a large number of semen collections that were performed via the transrectal massage (TRM) of the accessory sexual glands of Italian yearling beef bulls and compare this semen collection method to the artificial vagina (AV) method in term of breeding soundness examination outcomes; furthermore, we determined whether the breed affected the semen characteristics. In the TRM group (n = 475), the semen samples were collected via TRM of the accessory sexual glands, and in the AV group (n = 502), the AV method was used. In the TRM group, semen samples were obtained from 81.3% of the bulls and penile protrusion was observed in 87.6% of the animals during semen collection. The sperm concentrations (920.5 ± 439.0 vs. 281.0 ± 259.8 × 10(6)/mL) and the percentages of total abnormal spermatozoa (22.8 ± 15.0 vs. 18.8 ± 12.9) were significantly higher in the AV group than those in the TRM group. The percentage of bulls that did not meet the minimum requirement for normal cells (≥70%) was 6.2% higher in the AV group than that in the TRM group (P < 0.05). Moreover, the samples collected from Chianina bulls by TRM exhibited a lower percentage of motile sperm and a higher percentage of abnormal spermatozoa when compared with the other two breeds. The major drawbacks of the TRM technique were the inability to conduct complete evaluation of the libido and mating ability of the yearling bulls, a significant reduction of the number of spermatozoa collected, and an increase in the variability of the semen characteristics due to breed. In conclusion, despite the drawbacks, TRM guarantees that semen evaluation can be conducted in cases in which the semen samples cannot be collected

  8. Effect of semen collection by transrectal massage of accessory sexual glands or artificial vagina on the outcome of breeding soundness examinations of Italian yearling beef bulls.

    PubMed

    Sylla, Lakamy; Palombi, Claudio; Stradaioli, Giuseppe; Vagniluca, Antonio; Monaci, Maurizio

    2015-03-15

    Although semen quality is one of the major traits that influence breeding soundness examination outcomes in bulls, field conditions occasionally do not allow for the collection of semen samples by means of an artificial vagina. The aims of the present study were to report the results of a large number of semen collections that were performed via the transrectal massage (TRM) of the accessory sexual glands of Italian yearling beef bulls and compare this semen collection method to the artificial vagina (AV) method in term of breeding soundness examination outcomes; furthermore, we determined whether the breed affected the semen characteristics. In the TRM group (n = 475), the semen samples were collected via TRM of the accessory sexual glands, and in the AV group (n = 502), the AV method was used. In the TRM group, semen samples were obtained from 81.3% of the bulls and penile protrusion was observed in 87.6% of the animals during semen collection. The sperm concentrations (920.5 ± 439.0 vs. 281.0 ± 259.8 × 10(6)/mL) and the percentages of total abnormal spermatozoa (22.8 ± 15.0 vs. 18.8 ± 12.9) were significantly higher in the AV group than those in the TRM group. The percentage of bulls that did not meet the minimum requirement for normal cells (≥70%) was 6.2% higher in the AV group than that in the TRM group (P < 0.05). Moreover, the samples collected from Chianina bulls by TRM exhibited a lower percentage of motile sperm and a higher percentage of abnormal spermatozoa when compared with the other two breeds. The major drawbacks of the TRM technique were the inability to conduct complete evaluation of the libido and mating ability of the yearling bulls, a significant reduction of the number of spermatozoa collected, and an increase in the variability of the semen characteristics due to breed. In conclusion, despite the drawbacks, TRM guarantees that semen evaluation can be conducted in cases in which the semen samples cannot be collected

  9. Seminal vesicles of infertile patients with male accessory gland infection: ultrasound evaluation after prolonged treatment with tadalafil, a selective phosphodiesterase-5 inhibitor.

    PubMed

    La Vignera, S

    2013-12-01

    The aim of this study was to investigate possible ultrasound seminal vesicle (SV) changes in infertile patients with 'hypertrophic-congestive' (HCUF) or 'fibro-sclerotic' (FSUF) ultrasound form of male accessory gland infection (MAGI) after prolonged administration of tadalafil (TAD), a selective phosphodiesterase-5 inhibitor. Forty infertile patients with HCUF and 40 patients with FSUF and erectile dysfunction were selected and arbitrarily divided into two groups, who were prescribed TAD 5 mg daily for 3 months, the first 20 consecutive patients with HCUF (group A1) or FSUF (group A2) or placebo, the second 20 consecutive patients with HCUF (group B1) or FSUF (group B2). All patients underwent scrotal and prostate-vesicular transrectal ultrasound evaluation and semen analysis (WHO, 2010) before and after treatment. Group A1 patients showed a significant reduction in fundus/body ratio and higher pre- and post-ejaculatory body SV antero-posterior diameter difference compared with the other three groups. These patients showed also a significant increase in SV ejection fraction and a significant improvement in the total sperm count, progressive motility, seminal levels of fructose and ejaculate volume. These results suggest that infertile patients with HCUF had an improvement in SV ultrasound features suggestive of chronic inflammation after daily treatment with low doses of TAD.

  10. Effects of Pygidial Secretion (Zoopesticide) on Histopathological Changes in the Male Accessory Reproductive Glands of Adult Male Insect Odontopus varicornis in Relation to Reproduction

    PubMed Central

    Lousia, M.; Selvisabhanayakam; Mathivanan, V.

    2010-01-01

    Indiscriminate use of pesticides for the eradication of pests causes tremendous changes to the environment and also to other nontarget organisms. To prevent such contamination of the environment and save nontarget species, zoopesticides are increasingly used as they are cost effective, eco-friendly, safe, and sustainable in the field of agriculture. The present study was undertaken to find out the effect of pygidial secretion (zoopesticide) on Odontopus varicornis. The insects were exposed to pygidial secretion for 24, 48, 72, and 96 hours and its sublethal concentration was found to be about 2.8% for 48 hours. When the insects were injected with sublethal concentration 2.8% for 48 hours, the study revealed certain remarkable changes in the histopathology of the male accessory reproductive glands (MARGs) such as disintegration of epithelial cell wall, swollen nucleus, vacuolization of cytoplasm, highly pycnotic and necrotic epithelium, enlargement of epithelial cells, and disorganized tissues. It is suggested that zoopesticide causes several histopathological damages in the MARGs of O. varicornis and affects the reproductive potentiality of O. varicornis. PMID:21042469

  11. Juvenile hormone-stimulated synthesis of acyl-glycerols and vitamin E in female accessory sexual glands of the fire bug, Pyrrhocoris apterus L.

    PubMed

    Jedlicka, Pavel; Cvacka, Josef; Sláma, Karel

    2009-09-01

    Secretory cells of the female accessory sexual glands (AG) of P. apterus grow and produce yellow oily exocrine secretion in response to stimulation by endogenous juvenile hormone (JH) or exogenous treatments by JH analogues. The secretion determines the property of future egg shells by coating the chorion surface of the oocytes that are passing individually through the common uterus during oviposition. Diapausing females with a physiologically inhibited endocrine system or females with artificially removed hormonal sources show inactive ovaries and empty AG without the secretory products. Ovary-ectomised females with the intact neuroendocrine system develop hypertrophic AG loaded with the oily secretion. This shows that there is no direct dependence between formation of the oily secretion in AG and ovarian growth. Chemical analysis of the secretory products revealed the presence of acetylated glycerols, with the most abundant stearoyl-diacetyl-glycerol, stearoyl-acetyl-propionyl-glycerol, and the corresponding derivatives of arachidonic acid. In addition to this, the JH-activated secretory cells of AG also produced gamma- and delta-tocopherols. The possible antioxidant or antimutagenic action of these vitamin E compounds in insect reproduction has been emphasized.

  12. Demystifying Mag-Lev.

    ERIC Educational Resources Information Center

    Ruiz, Ernest; And Others

    1991-01-01

    Presented are classroom activities in which students explore the potential use of magnetic levitation for transportation purposes. The advantages of using a MagLev transportation system instead of conventional trains are discussed. Directions for designing and building a MagLev track and circuit are provided. (KR)

  13. Sexual behavior attenuates the effects of chronic stress in body weight, testes, sexual accessory glands, and plasma testosterone in male rats.

    PubMed

    Retana-Márquez, S; Vigueras-Villaseñor, R M; Juárez-Rojas, L; Aragón-Martínez, A; Torres, G Reyes

    2014-11-01

    The aim of this study was to evaluate whether continuous sexual behavior could attenuate the effects of chronic stress on spermatogenesis, sexual glands, plasma testosterone and corticosterone in sexually experienced male rats. Rats were exposed to stress by immersion in cold water (ICW) daily for 20 or 50 consecutive days. Plasma testosterone and corticosterone, masculine sexual behavior, as well as the number of offspring, the epithelial area of seminiferous, prostatic and seminal glands were assessed. In stressed males, body and testicular weights decreased, male sexual behavior was disrupted, and adrenal weights increased. In males stressed for 50 days, prostate and seminal glands had lower weights compared with controls. Prostate and seminal epithelial areas also decreased in these males. Seminiferous tubules in testes from rats stressed for 20 or 50 days showed several degenerative signs, such as vacuoles in the basal epithelium, with picnotic indicia; moderate to severe exfoliation of degenerative germinal cells in the tubule lumen was also observed. In males stressed for 50 days a significant decrease in seminiferous epithelial area was observed from stages I-VIII, regardless of copulation. The litters from females that copulated with males stressed for 50 days decreased significantly. Chronic stress caused increase in plasma levels of corticosterone, which were higher in males stressed for 20 days than in males stressed for 50 days. Testosterone decreased in stressed males and it was lower in males stressed for 50 days. In stressed males allowed to copulate, body and testicular weights were similar to controls. Adrenal, seminal glands, and prostate weights, as well as epithelial areas of males stressed for 50 days allowed to copulate were also similar to controls. Corticosterone was lower than in males stressed for 50 days, but still higher than in controls. Testosterone in males stressed for 50 days and allowed to copulate was higher than in stressed

  14. Physiological responses and characteristics of sperm collected after electroejaculation or transrectal ultrasound-guided massage of the accessory sex glands in anesthetized mouflons (Ovis musimon) and Iberian ibexes (Capra pyrenaica).

    PubMed

    Ungerfeld, Rodolfo; López-Sebastián, Antonio; Esteso, Milagros; Pradiee, Jorgea; Toledano-Díaz, Adolfo; Castaño, Cristina; Labrador, Beatriz; Santiago-Moreno, Julián

    2015-10-15

    The objective was to characterize the stress response and the seminal parameters obtained with electroejaculation (EE) or transrectal ultrasound-guided massage of the accessory sex glands (TUMASG) in two captive but nondomestic ruminants, the mouflons and the Iberian ibex under general anesthesia. In mouflons, the physiological responses (heart and respiratory rate, rectal temperature, cortisol, creatine kinase, potassium and glucose concentrations) changed similarly with both procedures. The TUMASG procedure was faster than EE in mouflons (21.7 ± 1.4 vs. 12.4 ± 1.2 minutes, P < 0.01). In ibexes, respiratory rate, cortisol and creatine kinase concentration changes were greater with EE than with TUMASG (final respiratory rate: 62.7 ± 5.5 vs. 38.1 ± 5.6 breaths/min [P < 0.05]; final cortisol: 51.4 ± 5.1 vs. 25.3 ± 5.6 ng/mL [P < 0.001]; and final creatine kinase: 300.9 ± 99.9 vs. 87.1 ± 16.9 U/L [P < 0.001]). Electroejaculation provided better results in some sperm parameters (mouflons: sperm score: 3.4 ± 0.3 vs. 2.6 ± 0.2 [P < 0.01]; total number of sperm ejaculated: 982.4 ± 299 vs. 710.0 ± 542.2 [P < 0.05]; ibexes: sperm with progressive motility: 47.7 ± 6.2 vs. 20.5 ± 8.3 [P < 0.05]). The transrectal ultrasound-guided massage of the accessory sex glands appears to be an alternative technique to collect sperm from wild ruminants, reducing the need for electrical stimuli and thus decreasing the undesired responses of EE in the more sensitive species. On the other hand, better fresh sperm may be collected with EE. However, TUMASG provides practical advantages in animal welfare, firstly in these wild species more sensible to stress management and capture myopathy.

  15. THOR Fluxgate Magnetometer (MAG)

    NASA Astrophysics Data System (ADS)

    Nakamura, Rumi; Eastwood, Jonathan; Magnes, Werner; Valavanoglou, Aris; Carr, Christopher M.; O'Brien, Helen L.; Narita, Yasuhito; Delva, Magda; Chen, Christopher H. K.; Plaschke, Ferdinand; Soucek, Jan

    2016-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The goal of the Fluxgate Magnetometer (MAG) is to measure the DC to low frequency ambient magnetic field. The design of the magnetometer consists of two tri-axial sensors and the related magnetometer electronics; the electronics are hosted on printed circuit boards in the common electronics box of the fields and wave processor (FWP). A fully redundant two sensor system mounted on a common boom and the new miniaturized low noise design based on MMS and Solar Orbiter instruments enable accurate measurement throughout the region of interest for THOR science. The usage of the common electronics hosted by FWP guarantees to fulfill the required timing accuracy with other fields measurements. These improvements are important to obtain precise measurements of magnetic field, which is essential to estimate basic plasma parameters and correctly identify the spatial and temporal scales of the turbulence. Furthermore, THOR MAG provides high quality data with sufficient overlap with the Search Coil Magnetometer (SCM) in frequency space to obtain full coverage of the wave forms over all the frequencies necessary to obtain the full solar wind turbulence spectrum from MHD to kinetic range with sufficient accuracy.

  16. First transcriptome of the testis-vas deferens-male accessory gland and proteome of the spermatophore from Dermacentor variabilis (Acari: Ixodidae).

    PubMed

    Sonenshine, Daniel E; Bissinger, Brooke W; Egekwu, Noble; Donohue, Kevin V; Khalil, Sayed M; Roe, R Michael

    2011-01-01

    Ticks are important vectors of numerous human diseases and animal diseases. Feeding stimulates spermatogenesis, mating and insemination of male factors that trigger female reproduction. The physiology of male reproduction and its regulation of female development are essentially a black box. Several transcriptomes have catalogued expression of tick genes in the salivary glands, synganglion and midgut but no comprehensive investigation has addressed male reproduction and mating. Consequently, a new global approach using transcriptomics, proteomics, and quantitative gene expression is needed to understand male reproduction and stimulation of female reproduction.This first transcriptome to the reproductive biology of fed male ticks, Dermacentor variabilis, was obtained by 454 pyrosequencing (563,093 reads, 12,804 contigs). Gene Ontology (Biological Processes level III) recognized 3,866 transcripts in 73 different categories; spermiogenesis; spermatogenesis; peptidases, lipases and hydrolases; oxidative and environmental stress; immune defense; and protein binding. Reproduction-associated genes included serine/threonine kinase, metalloendoproteinases, ferritins, serine proteases, trypsin, cysteine proteases, serpins, a cystatin, GPCR and others. qRT-PCR showed significant upregulation from unfed versus fed adult male reproductive organs of zinc metalloprotease, astacin metalloprotease and serine protease, enzymes important in spermiogenesis and mating activity in insects, as well as a GPCR with the greatest similarity to a SIFamide receptor known to be important in regulating courtship behavior in Drosophila. Proteomics on these organs and the spermatophore by tryptic digestion/Liquid chromatography/Mass spectrometry/Mass spectrometry (LC/MS/MS) demonstrated expression of many of the same messages found by 454 sequencing, supporting their identification, and revealed differences in protein distribution in the reproductive system versus the spermatophore. We found Ef

  17. The Laser Accessory Market

    NASA Astrophysics Data System (ADS)

    Desai, Ashvin

    1988-09-01

    Wandering through the exhibit hall yesterday, I noticed that if you look at the laser companies and if you look at the accessory companies, there are pretty much the same number of accessory booths as well as the laser companies. There was one difference. Laser company booths are all sexy looking, very flashy, big booths. Whereas if you look at the accessories booths, they were small, not so prominent.

  18. Advantages of reusable accessories.

    PubMed

    Wolfsen, H C

    2000-04-01

    Despite scant evidence supporting the use of disposable accessories, these devices have been widely disseminated. Manufacturers and governmental regulators, the most devout proponents of one-time use accessories, have framed the issue in economic terms-parsimonious practitioners reusing disposable accessories at the risk of cross-contamination, mechanical failure and product liability. This simplistic view represents revisionist history and ignores the long tradition of reusing these devices. This article reviews the numerous studies that support the safe and cost effective reuse of disposable and reusable accessories.

  19. Minor salivary gland neoplasm in children.

    PubMed

    Spuntarelli, Giorgio; Santecchia, Luigino; Urbani, Urbano; Zama, Mario

    2013-03-01

    In this article, we present a review of the literature, and we focus on 2 particular cases of cancer of the salivary glands accessory in pediatric patients The accessory parotid is the site of congenital and acquired lesions. In adults, the acquired lesions are often neoplastic and are usually similar to those seen in the main parotid gland. The disorders in children are less well defined, as only a few cases have been reported.The accessory parotid gland, or accessory parotid, is a nodule of normal salivary tissue separated from the main parotid gland, located on the masseter muscle, to which it is bound by an extension of the masseteric fascia and connected to the Stensen duct at that level. In contrast to the extensive literature on acquired lesions of the accessory parotid in adults, very few cases of malignant or benign lesions of the accessory parotid in children could be found in the literature. A review of several articles reporting lesions of the accessory parotid in adult patients, reporting 3 or more cases each for a total of 71 patients, showed 24 malignant neoplasms, 39 benign neoplasms, and 8 nonneoplastic lesions. Lesions of the accessory parotid are quite rare in children but should be considered when facing mass located in the cheek.

  20. Endocrine glands

    MedlinePlus

    The endocrine system is primarily composed of glands that produce chemical messengers called hormones. Glands of the endocrine system include the pituitary gland, the thyroid gland, the parathyroid glands, the thymus, ...

  1. Chronic sclerosing sialadenitis of the parotid gland.

    PubMed

    de Vicente, Juan Carlos; López-Arranz, Elena; García, Juan; López-Arranz, Juan Sebastián

    2003-07-01

    Chronic sclerosing sialadenitis (Küttner's tumor) is a benign and chronic inflammatory condition of the submandibular gland that clinically cannot be easily distinguished from salivary malignant neoplasia. This is a report of a case of chronic sclerosing sialadenitis located as a solitary mass in an accessory parotid gland.

  2. Sialic Acid Is Required for Neuronal Inhibition by Soluble MAG but not for Membrane Bound MAG

    PubMed Central

    Al-Bashir, Najat; Mellado, Wilfredo; Filbin, Marie T.

    2016-01-01

    Myelin-Associated Glycoprotein (MAG), a major inhibitor of axonal growth, is a member of the immunoglobulin (Ig) super-family. Importantly, MAG (also known as Siglec-4) is a member of the Siglec family of proteins (sialic acid-binding, immunoglobulin-like lectins), MAG binds to complex gangliosides, specifically GD1a and/or GT1b. Therefore, it has been proposed as neuronal receptors for MAG inhibitory effect of axonal growth. Previously, we showed that MAG binds sialic acid through domain 1 at Arg118 and is able to inhibit axonal growth through domain 5. We developed a neurite outgrowth (NOG) assay, in which both wild type MAG and mutated MAG (MAG Arg118) are expressed on cells. In addition we also developed a soluble form NOG in which we utilized soluble MAG-Fc and mutated MAG (Arg118-Fc). Only MAG-Fc is able to inhibit NOG, but not mutated MAG (Arg118)-Fc that has been mutated at its sialic acid binding site. However, both forms of membrane bound MAG- and MAG (Arg118)- expressing cells still inhibit NOG. Here, we review various results from different groups regarding MAG’s inhibition of axonal growth. Also, we propose a model in which the sialic acid binding is not necessary for the inhibition induced by the membrane form of MAG, but it is necessary for the soluble form of MAG. This finding highlights the importance of understanding the different mechanisms by which MAG inhibits NOG in both the soluble fragmented form and the membrane-bound form in myelin debris following CNS damage. PMID:27065798

  3. Accessory oral cavity

    PubMed Central

    Gnaneswaran, Manica Ramamoorthy; Varadarajan, Usha; Srinivasan, Ramesh; Kamatchi, Sangeetha

    2012-01-01

    This is a rare case report of a patient around 11 years with the complaint of extra mouth who reported to the hospital for removal of that extra mouth. On examination there was accessory oral cavity with small upper and lower lips, seven teeth and saliva was drooling out. Under general anesthesia crevicular incision from 32 to 43 was put and labial gingiva with alveolar mucosa was reflected completely and bone exposed to lower border of mandible. There were seven teeth resembling lower permanent anterior teeth in the accessory mouth, which was excised with the accessory lips. 41 extracted and osteotomy carried out extending the incision from the extracted site and osteotomy carried out. Dermoid cyst both below and above the mylohyoid muscle and rudimentary tongue found and excised and the specimen sent for histopathological examination. The wound was closed and uneventful healing noted to the satisfaction of the patient. This is a rare and interesting case which has been documented. PMID:23833508

  4. Accessory fissures of the lung

    SciTech Connect

    Godwin, D.; Tarver, R.D.

    1985-01-01

    Accessory fissures of the lung are commonly observed in lung specimens, but are often unappreciated or misinterpreted in radiographs and computer tomographic (CT) scans. They usually occur at the boundaries between bronchopulmonary segments. Most common are the inferior accessory fissure, which demarcates the medial basal segment; the superior accessory fissure, which demarcates the superior segment; and the left minor fissure, which demarcates the lingula. This essay will illustrate the findings of the common accessory fissures both on plain radiographs and on CT scans.

  5. Bilateral accessory thoracodorsal artery.

    PubMed

    Natsis, Konstantinos; Totlis, Trifon; Tsikaras, Prokopios; Skandalakis, Panagiotis

    2006-09-01

    The subscapular artery arises from the third part of the axillary artery and gives off the circumflex scapular and the thoracodorsal arteries. Although anatomical variations of the axillary artery are very common, the existence of a unilateral accessory thoracodorsal artery has been described in the literature only once. There are no reports of bilateral accessory thoracodorsal artery, in the literature. In the present study, a bilateral accessory thoracodorsal artery, originating on either side of the third part of the axillary artery, is described in a 68-year-old female cadaver. All the other branches of the axillary artery had a typical origin, course, distribution and termination. This extremely rare anatomical variation apart from the anatomical importance also has clinical significance for surgeons in this area. Especially, during the dissection or mobilization of the latissimus dorsi that is partly used for coverage problems in many regions of the body and also in dynamic cardiomyoplasty, any iatrogenic injury of this accessory artery may result in ischemia and functional loss of the graft.

  6. A National MagLev Transportation System

    NASA Technical Reports Server (NTRS)

    Wright, Michael R.

    2003-01-01

    The case for a national high-speed magnetic-levitation (MagLev) transportation system is presented. Focus is on current issues facing the country, such as national security, the economy, transportation, technology, and the environment. NASA s research into MagLev technology for launch assist is also highlighted. Further, current socio-cultural norms regarding motor-vehicle-based transportation systems are questioned in light of the problems currently facing the U.S. The multidisciplinary benefits of a long-distance MagLev system support the idea that such a system would be an important element of a truly multimodal U.S. transportation infrastructure.

  7. Iatrogenic accessory nerve injury.

    PubMed Central

    London, J.; London, N. J.; Kay, S. P.

    1996-01-01

    Accessory nerve injury produces considerable disability. The nerve is most frequently damaged as a complication of radical neck dissection, cervical lymph node biopsy and other surgical procedures. The problem is frequently compounded by a failure to recognise the error immediately after surgery when surgical repair has the greatest chance of success. We present cases which outline the risk of accessory nerve injury, the spectrum of clinical presentations and the problems produced by a failure to recognise the deficit. Regional anatomy, consequences of nerve damage and management options are discussed. Diagnostic biopsy of neck nodes should not be undertaken as a primary investigation and, when indicated, surgery in this region should be performed by suitably trained staff under well-defined conditions. Awareness of iatrogenic injury and its consequences would avoid delays in diagnosis and treatment. Images Figure 2 PMID:8678450

  8. Salivary Glands

    MedlinePlus

    ... salivary gland tumors usually show up as painless enlargements of these glands. Tumors rarely involve more than ... otolaryngologist-head and neck surgeon should check these enlargements. Malignant tumors of the major salivary glands can ...

  9. Pituitary gland

    MedlinePlus

    ... glands. Located above the pituitary gland is the hypothalamus. The hypothalamus decides which hormones the pituitary should release by ... messages. In response to hormonal messages from the hypothalamus, the pituitary gland releases the following hormones: GH ( ...

  10. Endocrine glands

    MedlinePlus

    Endocrine glands release (secrete) hormones into the bloodstream. The endocrine glands include: Adrenal Hypothalamus Islets of Langerhans in the pancreas Ovaries Parathyroid Pineal Pituitary Testes Thyroid

  11. Rhabdovirus accessory genes.

    PubMed

    Walker, Peter J; Dietzgen, Ralf G; Joubert, D Albert; Blasdell, Kim R

    2011-12-01

    The Rhabdoviridae is one of the most ecologically diverse families of RNA viruses with members infecting a wide range of organisms including placental mammals, marsupials, birds, reptiles, fish, insects and plants. The availability of complete nucleotide sequences for an increasing number of rhabdoviruses has revealed that their ecological diversity is reflected in the diversity and complexity of their genomes. The five canonical rhabdovirus structural protein genes (N, P, M, G and L) that are shared by all rhabdoviruses are overprinted, overlapped and interspersed with a multitude of novel and diverse accessory genes. Although not essential for replication in cell culture, several of these genes have been shown to have roles associated with pathogenesis and apoptosis in animals, and cell-to-cell movement in plants. Others appear to be secreted or have the characteristics of membrane-anchored glycoproteins or viroporins. However, most encode proteins of unknown function that are unrelated to any other known proteins. Understanding the roles of these accessory genes and the strategies by which rhabdoviruses use them to engage, divert and re-direct cellular processes will not only present opportunities to develop new anti-viral therapies but may also reveal aspects of cellar function that have broader significance in biology, agriculture and medicine.

  12. Macrophages: important accessory cells for reproductive function.

    PubMed

    Cohen, P E; Nishimura, K; Zhu, L; Pollard, J W

    1999-11-01

    Macrophages are found throughout reproductive tissues. To determine their role(s), we have studied mice homozygous for a null mutation (Csfm(op)) in the gene encoding the major macrophage growth factor, colony-stimulating factor-1 (CSF-1). Both male and female Csfm(op)/Csfm(op) mice have fertility defects. Males have low sperm number and libido as a consequence of dramatically reduced circulating testosterone. Females have extended estrous cycles and poor ovulation rates. CSF-1 is the principal growth factor regulating macrophage populations in the testis, male accessory glands, ovary, and uterus. However, analyses of CSF-1 nullizygous mice suggest that the primary reproductive defect is in the development of feedback regulation of the hypothalamic-pituitary axis. Although not correlating with deficiencies of microglia populations, electrophysiological investigations indicate an impairment of neuronal responses. This suggests that microglia, under the influence of CSF-1, act to organize neuronal connectivity during development and that the absence of this function results in a perturbation of the hypothalamic-pituitary-gonadal axis. Macrophages also appear to have functions in the differentiated tissues of the reproductive system, including having a positive influence on steroidogenic cells. These data suggest that macrophages, through their trophic functions, can be considered as essential accessory cells for normal reproductive functioning.

  13. The SuperMAG data processing technique

    NASA Astrophysics Data System (ADS)

    Gjerloev, J. W.

    2012-09-01

    In this paper I outline the data processing technique which is used in the SuperMAG initiative. SuperMAG is a worldwide collaboration of organizations and national agencies that currently operate more than 300 ground based magnetometers. SuperMAG provides easy access to validated ground magnetic field perturbations in the same coordinate system, identical time resolution and with a common baseline removal approach. The purpose of SuperMAG is to provide scientists, teachers, students and the general public easy access to measurements of the magnetic field at the surface of the Earth. Easy access to data, plots and derived products maximizes the utilization of this unique data set. It is outlined how SuperMAG processes the observations obtained by the individual data provider. Data are rotated into a local magnetic coordinate system by determining a time dependent declination angle. This angle displays a slow gradual change and a yearly periodic variation attributed to changes in the Earth main field and season temperature variations. The baseline is determined from the data itself in a three step process: (1) a daily baseline, (2) a yearly trend, and (3) a residual offset. This technique does not require so-called quiet days and thus it avoids all the well-known problems associated with their identification. The residual offset for the N- and Z-components shows a distinct latitudinal dependence while the E-component is independent of the latitude. This result is interpreted as being due to a weak ring current (likely asymmetric) which is present even during official quiet days. For the purpose of M-I research using 1-min data I find no difference between observatories and variometers. I finally argue that there is no correct baseline determination technique since we do not have a set of ground-truth observations required to make an objective evaluation. Instead, the user must keep in mind the assumptions on which the baseline was determined and draw conclusions

  14. Accessories or necessities? Exploring consensus on usage of stoma accessories.

    PubMed

    Rudoni, Caroline; Dennis, Heather

    Usage and opinion of accessory products in stoma care vary enormously. The aim of this study was to identify what constitutes an accessory product and to find out whether there is any standardization regarding their recommendation. Views of both patients and stoma nurses were examined. Patients identify accessory products as being necessary both physically and psychologically in improving their quality of life. While stoma nurses identify that the psychological effects of having a stoma should never be underestimated, there is still concern regarding the cost of recommending these products and their clinical necessity. It would appear that clinical necessity is based on nurses' opinions and is not always evidence or research based. Since accessory products have been shown to be essential to many patients with a stoma, should stoma nurses be more empathetic when considering their recommendation?

  15. Accessory Pancreatic Duct Patterns and Their Clinical Implications

    PubMed Central

    Prasanna, Lokadolalu Chandracharya; Rajagopal, KV; Thomas, Huban R

    2015-01-01

    Context and Objective: Accessory pancreatic duct (APD) designed to reduce the pressure of major pancreatic duct by forming a secondary drainage channel. Few studies have mentioned the variant types of accessory ducts and their mode of formation, some of these have a clear clinical significance. Present study is aimed to evaluate the possible variations in the APD and its terminations. Materials and Methods: Forty formalin fixed adult human pancreas with duodenum in situ specimens were studied by injecting 1% aqueous eosin, followed by piece meal dissection of the head of the pancreas from posterior surface. Formation, tributaries, relations, and the termination of the accessory pancreatic duct were noted and photographed. Results: Accessory ducts revealed 50% belonged to long type, 22.5% were of short and ansa pancreatica type each, and embryonic type of duct pattern was seen in 5% specimens. 75% of long type ducts showed positive patency with eosin dye, followed by ansa type (44.4%), and least patency was found in short type (22.2%). With regard to the patency of the accessory pancreatic ducts towards their termination, we found 52.5% of the accessory ducts and 5% of the embryonic type pancreatic ducts were patent and in 42.5% of the specimen the ducts were obliterated. In 85% of specimens the minor duodenal papillae was anterosuperior to the major papilla and superior to the major papillae in 10% of the cases, and in 5% minor papillae was absent. The average distance between the two papillae was 2.35 cm. Conclusion: The knowledge of the complex anatomical relations of the gland with its duct, duodenum and bile ducts are essential for the surgeons and sinologists to plan and perform both the diagnostic as well as therapeutic procedures effectively. PMID:25954609

  16. Split gland

    DOEpatents

    Petranto, J.J.

    1989-09-05

    A split gland having only three parts is described. The gland has substantially the same stability to the relative motion of the constituent half-gland members during the attachment process to a female fitting as have more complicated designs. Ease of manufacture and use result from the reduction in complexity of the present invention. 15 figs.

  17. Split gland

    DOEpatents

    Petranto, Joseph J.

    1989-01-01

    A split gland having only three parts is described. The gland has substantially the same stability to the relative motion of the constituent half-gland members during the attachment process to a female fitting as have more complicated designs. Ease of manufacture and use result from the reduction in complexity of the present invention.

  18. 14 CFR 33.25 - Accessory attachments.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Accessory attachments. 33.25 Section 33.25... STANDARDS: AIRCRAFT ENGINES Design and Construction; General § 33.25 Accessory attachments. The engine must operate properly with the accessory drive and mounting attachments loaded. Each engine accessory drive...

  19. Calibrating the Prominence Magnetometer (ProMag)

    NASA Astrophysics Data System (ADS)

    Fox, Lewis; Casini, R.

    2013-07-01

    The Prominence Magnetometer (ProMag) is a dual-channel, dual-beam, slit-scanning, full Stokes spectro-polarimeter designed by the High Altitude Observatory at the National Center for Atmospheric Research (HAO/NCAR) for the study of the magnetism of solar prominences and filaments. It was deployed in August 2009 at the 40 cm coronagraph of the Evans Solar Facility (ESF) of the National Solar Observatory on Sacramento Peak (NSO/SP). In its standard mode of operation it acquires spectro-polarimetric maps of solar targets simultaneously in the two chromospheric lines of He I at 587.6 nm and 1083.0 nm. Since August 2011 ProMag has operated in “patrol mode” with a dedicated observer. We aim to routinely measure the vector magnetic field in prominences. The electro-optic modulator and polarization analyzer are integrated into a single mechanical unit located at the coude feed of the telescope. This location was necessary for proper co-alignment of the dual beams, but complicates the precise polarimeter calibration necessary to achieve the sensitivity required for prominence measurements (< 10^-3). At this sensitivity, small variations in optical alignment can become significant. We present a calibration method for ProMag, using a polarizer and retarder at coronagraph prime focus. Calibrations are recorded before and after observations. We discuss the success of this method and its limitations.

  20. Implementation of cargo MagLev in the United States

    SciTech Connect

    Rose, Chris R; Peterson, Dean E; Leung, Eddie M

    2008-01-01

    Numerous studies have been completed in the United States, but no commercial MagLev systems have been deployed. Outside the U.S., MagLev continues to attract funding for research, development and implementation. A brief review of recent global developments in MagLev technology is given followed by the status of MagLev in the U.S. The paper compares the cost of existing MagLev systems with other modes of transport, notes that the near-term focus of MagLev development in the U.S. should be for cargo, and suggests that future MagLev systems should be for very high speed cargo. The Los Angeles to Port of Los Angeles corridor is suggested as a first site for implementation. The benefits of MagLev are described along with suggestions on how to obtain funding.

  1. How MAG4 Improves Space Weather Forecasting

    NASA Technical Reports Server (NTRS)

    Falconer, David; Khazanov, Igor; Barghouty, Nasser

    2013-01-01

    Dangerous space weather is driven by solar flares and Coronal Mass Ejection (CMEs). Forecasting flares and CMEs is the first step to forecasting either dangerous space weather or All Clear. MAG4 (Magnetogram Forecast), developed originally for NASA/SRAG (Space Radiation Analysis Group), is an automated program that analyzes magnetograms from the HMI (Helioseismic and Magnetic Imager) instrument on NASA SDO (Solar Dynamics Observatory), and automatically converts the rate (or probability) of major flares (M- and X-class), Coronal Mass Ejections (CMEs), and Solar Energetic Particle Events.

  2. Photon emission intensities in the decay of 108mAg and 110mAg.

    PubMed

    Ferreux, L; Lépy, M-C; Bé, M-M; Isnard, H; Lourenço, V

    2014-05-01

    This study focuses on two radioisotopes of silver, (108m)Ag and (110m)Ag, characterized by a complex decay scheme. Each isotope has two disintegration modes, the isomeric transition leading to the daughter isotope ((108)Ag and (110)Ag, respectively) with a short half-life. The radioactive solution was obtained by neutron activation on silver powder enriched in (109)Ag. Gamma-spectrometry was carried out using a calibrated high purity germanium detector. The main relative photon emission intensities for both radionuclides were obtained and compared with previously published values.

  3. The arterial circulation of the left suprarenal gland.

    PubMed

    Bianchi, H; Ferrari, A

    1991-01-01

    The findings in a study of the general circulation of the suprarenal glands in 25 cases, and particularly of the left glands in 50 cases, are presented. The vessels arose from three pedicles: superior, middle and inferior. The inferior pedicle was the most irregular, with a frequent contribution from the gonadal artery to the inferior part of the gland; this artery should not be regarded as merely an accessory vessel. On the left side an inconstant posterior pedicle, separate from the others, was found in 26% of cases. Two forms of gonadal artery supplying the gland (8%) are described, an upper origin type at the renal artery level and an aberrant type.

  4. Automobile accessories: Assessment and improvement

    SciTech Connect

    Jackson, M.

    1995-11-01

    With mandates and regulatory policies to meet both the California Air Resources Board (CARB) and the Partnership for a New Generation of Vehicles (PNGV), designing vehicles of the future will become a difficult task. As we look into the use of electric and hybrid vehicles, reduction of the required power demand by influential automobile components is necessary in order to obtain performance and range goals. Among those automobile components are accessories. Accessories have a profound impact on the range and mileage of future vehicles with limited amounts of energy or without power generating capabilities such as conventional vehicles. Careful assessment of major power consuming accessories helps us focus on those that need improvement and contributes to attainment of mileage and range goals for electric and hybrid vehicles.

  5. Advantages of disposable endoscopic accessories.

    PubMed

    Petersen, B T

    2000-04-01

    Despite the prevailing emphasis on falling reimbursements and cost containment, the use of disposable endoscopic accessories has grown tremendously. They offer simplicity of use, certain sterility, and reduced labor costs in exchange for higher purchase costs per procedure and the burden of waste disposal. Disposable accessories provide greater variety, complexity, and utility. They carry a cost burden that may be acceptable when the devices are difficult to reprocess, when they incorporate features that justify the added cost, or when their unit cost approaches purchase plus reprocessing costs for reusable alternatives, such as for biopsy forceps. Units with small volumes may prefer the ease of disposable accessories independent of relative cost issues, while large high-volume units may need to evaluate cost data more carefully to maintain sustainable practices.

  6. Recurrent malignant salivary gland neoplasms.

    PubMed

    Rodriguez-Bigas, M A; Sako, K; Razack, M S; Shedd, D P; Bakamjian, V Y; Castillo, N B; Rao, U

    1989-10-01

    Recurrent salivary gland malignancies present difficult therapeutic decisions and poor prognosis in many instances, and treatment becomes of a palliative nature only. As many of the salivary gland malignancies we see are of the recurrent type, the following study was done to determine the efficacy of a vigorous attempt at retreatment. During the period January 1, 1960, through December 31, 1984, 352 patients with major and minor salivary gland tumors were evaluated at our institution. There were 149 benign lesions and 203 patients with malignant tumors. Of these, 99 patients had recurrent and metastatic tumors that had been treated initially elsewhere. Thirty-three of these patients were able to be treated with curative intent: surgery, 21; surgery plus radiation, 9; radiation therapy alone, 2; and radiation plus chemotherapy, 1. The 5 year survival with no evidence of disease was achieved in three patients with surgery alone and two patients with surgery plus radiation therapy. The group of five patients was comprised of two patients with adenoid cystic carcinomas of the parotid, one with intermediate grade mucoepidermoid carcinoma of the parotid, one, sebaceous cell carcinoma of the parotid, and one, adenoid cystic carcinoma of an accessory salivary gland. The results of this study serve to re-emphasize the relative poor yield of attempts at retreatment of loco-regional recurrence of salivary gland tumors.

  7. Intrahepatic accessory spleen: imaging features.

    PubMed

    Izzo, Luciano; Caputo, Maria; Galati, Gaspare

    2004-06-01

    The authors present a case report of a 60-year-old man with a hepatic unknown mass. For diagnosis, they used ECO, CT (with and without contrast), MR (with and without contrast) and an ultrasound-assisted percutaneous lesion biopsy. Thus the mass-lesion in the liver appeared to be an intrahepatic accessory spleen in a patient afflicted with chronic hepatitis.

  8. Teaching Techniques for Accessory Percussion

    ERIC Educational Resources Information Center

    Micallef, Ken

    2007-01-01

    Everyone is familiar with the main percussion instruments of the contemporary orchestra: bass drum, snare drum, suspended cymbal, vibraphone, and timpani. But as source material broadens, so do the demands placed on the percussion section. Accessory, or auxiliary percussion, can make the difference between a typical rendition of a well-known piece…

  9. Melanocortin receptor accessory proteins in adrenal disease and obesity

    PubMed Central

    Jackson, David S.; Ramachandrappa, Shwetha; Clark, Adrian J.; Chan, Li F.

    2015-01-01

    Melanocortin receptor accessory proteins (MRAPs) are regulators of the melanocortin receptor family. MRAP is an essential accessory factor for the functional expression of the MC2R/ACTH receptor. The importance of MRAP in adrenal gland physiology is demonstrated by the clinical condition familial glucocorticoid deficiency type 2. The role of its paralog melanocortin-2-receptor accessory protein 2 (MRAP2), which is predominantly expressed in the hypothalamus including the paraventricular nucleus, has recently been linked to mammalian obesity. Whole body deletion and targeted brain specific deletion of the Mrap2 gene result in severe obesity in mice. Interestingly, Mrap2 complete knockout (KO) mice have increased body weight without detectable changes to food intake or energy expenditure. Rare heterozygous variants of MRAP2 have been found in humans with severe, early-onset obesity. In vitro data have shown that Mrap2 interaction with the melanocortin-4-receptor (Mc4r) affects receptor signaling. However, the mechanism by which Mrap2 regulates body weight in vivo is not fully understood and differences between the phenotypes of Mrap2 and Mc4r KO mice may point toward Mc4r independent mechanisms. PMID:26113808

  10. Locally vascularized pelvic accessory spleen.

    PubMed

    Iorio, F; Frantellizzi, V; Drudi, Francesco M; Maghella, F; Liberatore, M

    2016-01-01

    Polysplenism and accessory spleen are congenital, usually asymptomatic anomalies. A rare case of polysplenism with ectopic spleen in pelvis of a 67-year-old, Caucasian female is reported here. A transvaginal ultrasound found a soft well-defined homogeneous and vascularized mass in the left pelvis. Patient underwent MRI evaluation and contrast-CT abdominal scan: images with parenchymal aspect, similar to spleen were obtained. Abdominal scintigraphy with 99mTc-albumin nanocolloid was performed and pelvic region was studied with planar scans and SPECT. The results showed the presence of an uptake area of the radiopharmaceutical in the pelvis, while the spleen was normally visualized. These findings confirmed the presence of an accessory spleen with an artery originated from the aorta and a vein that joined with the superior mesenteric vein. To our knowledge, in the literature, there is just only one case of a true ectopic, locally vascularized spleen in the pelvis.

  11. Review: The Lacrimal Gland and Its Role in Dry Eye

    PubMed Central

    Conrady, Christopher D.; Joos, Zachary P.; Patel, Bhupendra C. K.

    2016-01-01

    The human tear film is a 3-layered coating of the surface of the eye and a loss, or reduction, in any layer of this film may result in a syndrome of blurry vision and burning pain of the eyes known as dry eye. The lacrimal gland and accessory glands provide multiple components to the tear film, most notably the aqueous. Dysfunction of these glands results in the loss of aqueous and other products required in ocular surface maintenance and health resulting in dry eye and the potential for significant surface pathology. In this paper, we have reviewed products of the lacrimal gland, diseases known to affect the gland, and historical and emerging dry eye therapies targeting lacrimal gland dysfunction. PMID:27042343

  12. CrowdMag - Crowdsourcing magnetic data

    NASA Astrophysics Data System (ADS)

    Nair, M. C.; Boneh, N.; Chulliat, A.

    2014-12-01

    In the CrowdMag project, we explore whether digital magnetometers built in modern mobile phones can be used as scientific instruments to measure Earth's magnetic field. Most modern mobile phones have digital magnetometers to orient themselves. A phone's magnetometer measures three components of the local magnetic field with a typical sensitivity of about 150 to 600 nanotesla (nT). By combining data from vector magnetometers and accelerometers, phone's orientation is determined. Using phone's Internet connection, magnetic data and location are sent to a central server. At the server, we check quality of the magnetic data from all users and make the data available to the public as aggregate maps. We have two long-term goals. 1) Develop near-real-time models of Earth's time changing magnetic field by reducing man-made noise from crowdsourced data and combining it with geomagnetic data from other sources. 2) Improving accuracy of magnetic navigation by mapping magnetic noise sources (for e.g. power transformer and iron pipes). Key challenges to this endeavor are the low sensitivity of the phone's magnetometer and the noisy environment within and surrounding the phone. URL : http://www.ngdc.noaa.gov/geomag/crowdmag.shtml

  13. Adrenal Gland Disorders

    MedlinePlus

    The adrenal glands are small glands located on top of each kidney. They produce hormones that you can't live ... stress and has many other important functions. With adrenal gland disorders, your glands make too much or not ...

  14. Accessory spleen hypertrophy mimicking colon cancer metastasis.

    PubMed

    Ates, I; Yazici, O; Yazilitas, D; Ozdemir, N; Zengin, N

    2016-09-01

    Accessory spleen is a congenital form of an ectopic splenic tissue. In this report, we present a case of a patient who was followed with the diagnosis of rectal and sigmoid colon cancer and an accessory spleen hypertrophy, which was thought to be colon cancer metastasis in the left hypochondriac region. After colectomy and splenectomy, accessory spleen that mimics cancer metastasis was diffrentially diagnosed using scintigraphy. PMID:27685531

  15. Advanced Accessory Power Supply Topologies

    SciTech Connect

    Marlino, L.D.

    2010-06-15

    This Cooperative Research and Development Agreement (CRADA) began December 8, 2000 and ended September 30, 2009. The total funding provided by the Participant (General Motors Advanced Technology Vehicles [GM]) during the course of the CRADA totaled $1.2M enabling the Contractor (UT-Battelle, LLC [Oak Ridge National Laboratory, a.k.a. ORNL]) to contribute significantly to the joint project. The initial task was to work with GM on the feasibility of developing their conceptual approach of modifying major components of the existing traction inverter/drive to develop low cost, robust, accessory power. Two alternate methods for implementation were suggested by ORNL and both were proven successful through simulations and then extensive testing of prototypes designed and fabricated during the project. This validated the GM overall concept. Moreover, three joint U.S. patents were issued and subsequently licensed by GM. After successfully fulfilling the initial objective, the direction and duration of the CRADA was modified and GM provided funding for two additional tasks. The first new task was to provide the basic development for implementing a cascaded inverter technology into hybrid vehicles (including plug-in hybrid, fuel cell, and electric). The second new task was to continue the basic development for implementing inverter and converter topologies and new technology assessments for hybrid vehicle applications. Additionally, this task was to address the use of high temperature components in drive systems. Under this CRADA, ORNL conducted further research based on GM’s idea of using the motor magnetic core and windings to produce bidirectional accessory power supply that is nongalvanically coupled to the terminals of the high voltage dc-link battery of hybrid vehicles. In order not to interfere with the motor’s torque, ORNL suggested to use the zero-sequence, highfrequency harmonics carried by the main fundamental motor current for producing the accessory power

  16. Mechanical accessories for mobile teleoperators

    SciTech Connect

    Feldman, M.J.; Herndon, J.N.

    1985-01-01

    The choice of optimum mechanical accessories for mobile teleoperators involves matching the criteria for emergency response with the available technology. This paper presents a general background to teleoperations, a potpourri of the manipulator systems available, and an argument for force reflecting manipulation. The theme presented is that the accomplishment of humanlike endeavors in hostile environments will be most successful when man model capabilities are utilized. The application of recent electronic technology to manipulator development has made new tools available to be applied to emergency response activities. The development activities described are products of the Consolidated Fuel Reprocessing Program at the Oak Ridge National Laboratory. 13 refs., 7 figs.

  17. The pineal gland from development to function.

    PubMed

    Sapède, Dora; Cau, Elise

    2013-01-01

    The pineal gland is a small neuroendocrine organ whose main and most conserved function is the nighttime secretion of melatonin. In lower vertebrates, the pineal gland is directly photosensitive. In contrast, in higher vertebrates, the direct photosensitivity of the pineal gland had been lost. Rather, the action of this gland as a relay between environmental light conditions and body functions involves reception of light information by the retina. In parallel to this sensory regression, the pineal gland (and its accessory organs) appears to have lost several functions in relation to light and temperature, which are important in lower vertebrate species. In humans, the functions of the pineal gland overlap with the functions of melatonin. They are extremely widespread and include general effects both on cell protection and on more precise functions, such as sleep and immunity. Recently, the role of melatonin has received a considerable amount of attention due to increased cancer risk in shift workers and the discovery that patients suffering from neurodegenerative diseases, autism, or depression exhibit abnormal melatonin rhythms.

  18. 14 CFR 27.1163 - Powerplant accessories.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Unless other means are provided, torque... drive system to prevent damage to these components from excessive accessory load. Powerplant...

  19. 14 CFR 27.1163 - Powerplant accessories.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Unless other means are provided, torque... drive system to prevent damage to these components from excessive accessory load. Powerplant...

  20. Three Accessories for a Rotating Platform.

    ERIC Educational Resources Information Center

    Riley, James A.; Fryer, Oscar G.

    1980-01-01

    Describes three accessories developed to be used in conjunction with the rotating platform or turntable. Three demonstrations using these accessories are included. These demonstrations are: (a) conservation of angular momentum; (b) gravity-defying goblets; and (c) direct measurement of centripetal force. (HM)

  1. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory....

  2. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory....

  3. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory....

  4. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory....

  5. 21 CFR 890.5925 - Traction accessory.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Traction accessory. 890.5925 Section 890.5925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5925 Traction accessory....

  6. Carcinoma in accessory axillary breast.

    PubMed

    Khanna, Seema; Mishra, Shashi Prakash; Kumar, Satendra; Khanna, Ajay Kumar

    2015-08-10

    We present a rare case of carcinoma developing in an accessory breast. The patient presented with a progressive lump in her right axilla for 1 year. On examination, there was a well-developed nipple areola complex in the right axilla overlying a hard, fixed 5 × 3 cm lump. On investigation, core biopsy revealed poorly differentiated carcinoma of the breast. Mammography also revealed features of a malignant lesion with skin and muscle infiltration. Neoadjuvant chemotherapy was administered followed by modified radical mastectomy after three cycles. Immunohistochemistry study showed positive status of oestrogen and progesterone receptors, and negative HER-2 neu. Three more cycles of chemotherapy along with 50 Gy radiotherapy were given in an adjuvant setting followed by hormone therapy.

  7. Salivary gland biopsy

    MedlinePlus

    Biopsy - salivary gland ... You have several pairs of salivary glands that drain into your mouth: A major pair in front of the ears (parotid glands) Another major pair beneath your jaw (submandibular ...

  8. Thymus Gland Anatomy

    MedlinePlus

    ... historical Searches are case-insensitive Thymus Gland, Adult, Anatomy Add to My Pictures View /Download : Small: 720x576 ... Large: 3000x2400 View Download Title: Thymus Gland, Adult, Anatomy Description: Anatomy of the thymus gland; drawing shows ...

  9. Salivary Gland Disorders

    MedlinePlus

    Your salivary glands make saliva - sometimes called spit - and empty it into your mouth through openings called ducts. Saliva makes your ... antibodies that can kill germs. Problems with salivary glands can cause the glands to become irritated and ...

  10. MagLev Cobra: Test Facilities and Operational Experiments

    NASA Astrophysics Data System (ADS)

    Sotelo, G. G.; Dias, D. H. J. N.; de Oliveira, R. A. H.; Ferreira, A. C.; De Andrade, R., Jr.; Stephan, R. M.

    2014-05-01

    The superconducting MagLev technology for transportation systems is becoming mature due to the research and developing effort of recent years. The Brazilian project, named MagLev-Cobra, started in 1998. It has the goal of developing a superconducting levitation vehicle for urban areas. The adopted levitation technology is based on the diamagnetic and the flux pinning properties of YBa2Cu3O7-δ (YBCO) bulk blocks in the interaction with Nd-Fe-B permanent magnets. A laboratory test facility with permanent magnet guideway, linear induction motor and one vehicle module is been built to investigate its operation. The MagLev-Cobra project state of the art is presented in the present paper, describing some construction details of the new test line with 200 m.

  11. 19 CFR 10.920 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 1 2012-04-01 2012-04-01 false Accessories, spare parts, or tools. 10.920 Section... Promotion Agreement Rules of Origin § 10.920 Accessories, spare parts, or tools. (a) General. Accessories... accessories, spare parts, or tools will be treated as originating goods if the good is an originating...

  12. 19 CFR 10.456 - Accessories, spare parts or tools.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... good will be treated as a material used in the production of the good, if— (a) The accessories, spare... 19 Customs Duties 1 2014-04-01 2014-04-01 false Accessories, spare parts or tools. 10.456 Section... Trade Agreement Rules of Origin § 10.456 Accessories, spare parts or tools. Accessories, spare parts...

  13. 19 CFR 10.920 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 1 2013-04-01 2013-04-01 false Accessories, spare parts, or tools. 10.920 Section... Promotion Agreement Rules of Origin § 10.920 Accessories, spare parts, or tools. (a) General. Accessories... accessories, spare parts, or tools will be treated as originating goods if the good is an originating...

  14. 19 CFR 10.456 - Accessories, spare parts or tools.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... good will be treated as a material used in the production of the good, if— (a) The accessories, spare... 19 Customs Duties 1 2011-04-01 2011-04-01 false Accessories, spare parts or tools. 10.456 Section... Trade Agreement Rules of Origin § 10.456 Accessories, spare parts or tools. Accessories, spare parts...

  15. 19 CFR 10.456 - Accessories, spare parts or tools.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... good will be treated as a material used in the production of the good, if— (a) The accessories, spare... 19 Customs Duties 1 2012-04-01 2012-04-01 false Accessories, spare parts or tools. 10.456 Section... Trade Agreement Rules of Origin § 10.456 Accessories, spare parts or tools. Accessories, spare parts...

  16. 19 CFR 10.456 - Accessories, spare parts or tools.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... good will be treated as a material used in the production of the good, if— (a) The accessories, spare... 19 Customs Duties 1 2013-04-01 2013-04-01 false Accessories, spare parts or tools. 10.456 Section... Trade Agreement Rules of Origin § 10.456 Accessories, spare parts or tools. Accessories, spare parts...

  17. 19 CFR 10.456 - Accessories, spare parts or tools.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... good will be treated as a material used in the production of the good, if— (a) The accessories, spare... 19 Customs Duties 1 2010-04-01 2010-04-01 false Accessories, spare parts or tools. 10.456 Section... Trade Agreement Rules of Origin § 10.456 Accessories, spare parts or tools. Accessories, spare parts...

  18. 19 CFR 10.920 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Accessories, spare parts, or tools. 10.920 Section... Promotion Agreement Rules of Origin § 10.920 Accessories, spare parts, or tools. (a) General. Accessories... accessories, spare parts, or tools will be treated as originating goods if the good is an originating...

  19. 14 CFR 29.1163 - Powerplant accessories.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... continued rotation of an engine-driven cabin supercharger or any remote accessory driven by the engine will be a hazard if they malfunction, there must be means to prevent their hazardous rotation...

  20. 14 CFR 23.1163 - Powerplant accessories.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... in the event it malfunctions. (d) If the continued rotation of any accessory remotely driven by the engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with...

  1. 14 CFR 29.1163 - Powerplant accessories.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... continued rotation of an engine-driven cabin supercharger or any remote accessory driven by the engine will be a hazard if they malfunction, there must be means to prevent their hazardous rotation...

  2. 14 CFR 23.1163 - Powerplant accessories.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... in the event it malfunctions. (d) If the continued rotation of any accessory remotely driven by the engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with...

  3. 14 CFR 23.1163 - Powerplant accessories.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... in the event it malfunctions. (d) If the continued rotation of any accessory remotely driven by the engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with...

  4. 14 CFR 23.1163 - Powerplant accessories.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... in the event it malfunctions. (d) If the continued rotation of any accessory remotely driven by the engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with...

  5. 14 CFR 23.1163 - Powerplant accessories.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... in the event it malfunctions. (d) If the continued rotation of any accessory remotely driven by the engine is hazardous when malfunctioning occurs, a means to prevent rotation without interfering with...

  6. 14 CFR 29.1163 - Powerplant accessories.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... continued rotation of an engine-driven cabin supercharger or any remote accessory driven by the engine will be a hazard if they malfunction, there must be means to prevent their hazardous rotation...

  7. 46 CFR 169.671 - Accessories.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Electrical Electrical Installations Operating at Potentials of Less Than 50 Volts on Vessels of Less Than 100 Gross Tons § 169.671 Accessories. Each light, receptacle and switch exposed to the weather must...

  8. The Accessory Genome of Pseudomonas aeruginosa

    PubMed Central

    Kung, Vanderlene L.; Ozer, Egon A.; Hauser, Alan R.

    2010-01-01

    Summary: Pseudomonas aeruginosa strains exhibit significant variability in pathogenicity and ecological flexibility. Such interstrain differences reflect the dynamic nature of the P. aeruginosa genome, which is composed of a relatively invariable “core genome” and a highly variable “accessory genome.” Here we review the major classes of genetic elements comprising the P. aeruginosa accessory genome and highlight emerging themes in the acquisition and functional importance of these elements. Although the precise phenotypes endowed by the majority of the P. aeruginosa accessory genome have yet to be determined, rapid progress is being made, and a clearer understanding of the role of the P. aeruginosa accessory genome in ecology and infection is emerging. PMID:21119020

  9. Radioactive Waste Decontamination Using Selentec Mag*SepSM Particles

    SciTech Connect

    Walker, D.D.

    1998-06-01

    A sorbent containing crystalline silicotitanate (CST) tested for cesium removal from simulated Savannah River Site (SRS) soluble high activity waste showed rapid kinetics (1 h contact time) and high distribution coefficients (Kd 4000 mL/g of CST). The sorbent was prepared by Selective Environmental Technologies, Inc., (Selentec) as a MAG*SEP particle containing CST obtained from the Molecular Sieve Department of UOP, LLC, Results of preliminary tests suggest potential applications of the Selentec MAG*SEP particles to radioactive waste decontamination at SRS.

  10. Laparoscopic excision of infarcted accessory spleen.

    PubMed

    Yousef, Yasmin; Cameron, Brian H; Maizlin, Zeev V; Boutross-Tadross, Odette

    2010-04-01

    An accessory spleen is present in about 10-30% of the population and, usually, does not cause symptoms. We present a case report of an unusual presentation of accessory spleen infarction, with a literature review. A 12-year old male presented with acute left-upper quadrant pain that slowly resolved. An ultrasound and computed tomography scan showed a 3.5 x 2.5 x 2 cm solid mass abutting and displacing the splenic flexure of the colon, with surrounding inflammatory changes. This was interpreted as a colonic duplication cyst, and the boy was treated with antibiotics and underwent elective laparoscopic exploration. It was removed laparoscopically without complication and, on pathologic examination, proved to be consistent with an infarcted accessory spleen. Less than two dozen similar cases of accessory spleen infarction have been reported in the literature, most presenting with acute abdominal pain. Preoperative diagnoses included appendicitis, ovarian torsion, neoplasm, and, in our case, colonic duplication. The natural course of infarcted accessory spleen would be to atrophy, but, even with advanced imaging techniques, it may be impossible to diagnose infarcted accessory spleen with enough confidence to avoid surgery.

  11. MagLIF scaling on Z and future machines

    NASA Astrophysics Data System (ADS)

    Slutz, Stephen; Stygar, William; Gomez, Matthew; Campbell, Edward; Peterson, Kyle; Sefkow, Adam; Sinars, Daniel; Vesey, Roger

    2015-11-01

    The MagLIF (Magnetized Liner Inertial Fusion) concept [S.A. Slutz et al Phys. Plasmas 17, 056303, 2010] has demonstrated [M.R. Gomez et al., PRL 113, 155003, 2014] fusion-relevant plasma conditions on the Z machine. We present 2D numerical simulations of the scaling of MagLIF on Z indicating that deuterium/tritium (DT) fusion yields greater than 100 kJ could be possible on Z when operated at a peak current of 25 MA. Much higher yields are predicted for MagLIF driven with larger peak currents. Two high performance pulsed-power machines (Z300 and Z800) have been designed based on Linear Transformer Driver (LTD) technology. The Z300 design would provide approximately 48 MA to a MagLIF load, while Z800 would provide about 66 MA. We used a parameterized Thevenin equivalent circuit to drive a series of 1D and 2D numerical simulations with currents between and beyond these two designs. Our simulations indicate that 5-10 MJ yields may be possible with Z300, while yields of about 1 GJ may be possible with Z800. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  12. Technology Of MIG-MAG Welds Strength Enhancement

    NASA Astrophysics Data System (ADS)

    Solodskiy, S. A.; Saraev, Yu N.; Malchik, A. G.; Korotkov, S. E.

    2016-08-01

    A new technology of MIG MAG welding control is developed. Authors introduce use of power AC and pulse feed of welding wire in the arc zone, that downsizes the heat affected zone, stabilizes formation of electrode metal droplets, as external magnetic field's effect on the arc is reduced. Principal criteria for electrode metal transfer control, when powered by AC sources, are specified.

  13. 21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY...

  14. 21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...

  15. 21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY...

  16. 21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...

  17. 21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY...

  18. 21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...

  19. 21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...

  20. 21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY...

  1. 21 CFR 878.4950 - Manual operating table and accessories and manual operating chair and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual operating table and accessories and manual operating chair and accessories. 878.4950 Section 878.4950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY...

  2. 21 CFR 878.4960 - Operating tables and accessories and operating chairs and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Operating tables and accessories and operating chairs and accessories. 878.4960 Section 878.4960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...

  3. The pineal gland.

    PubMed

    Paquette, H

    2000-04-01

    The pineal gland is located posterior to the midbrain and is the site of melatonin production. Research on pineal gland function in neonates is very limited. This article will discuss pineal gland development and the possible relationship between melatonin production and sudden infant death syndrome. Further research on pineal gland function is needed in order to establish its significance for the neonate.

  4. Controlled Speed Accessory Drive demonstration program

    NASA Technical Reports Server (NTRS)

    Hoehn, F. W.

    1981-01-01

    A Controlled Speed Accessory Drive System was examined in an effort to improve the fuel economy of passenger cars. Concept feasibility and the performance of a typical system during actual road driving conditions were demonstrated. The CSAD system is described as a mechanical device which limits engine accessory speeds, thereby reducing parasitic horsepower losses and improving overall vehicle fuel economy. Fuel consumption data were compiled for fleets of GSA vehicles. Various motor pool locations were selected, each representing different climatic conditions. On the basis of a total accumulated fleet usage of nearly three million miles, an overall fuel economy improvement of 6 percent to 7 percent was demonstrated. Coincident chassis dynamometer tests were accomplished on selected vehicles to establish the effect of different accessory drive systems on exhaust emissions, and to evaluate the magnitude of the mileage benefits which could be derived.

  5. Reutilization of accessories in gastrointestinal endoscopic practice.

    PubMed

    Haber, G

    2000-10-01

    The key issues that determine the decision between reusable versus disposable accessories are cost and functionality. In most health-care systems the availability and dissemination of endoscopic services relates directly to the resources (i.e. budget) of that system. Given the limitations of health-care budgets, access to endoscopic services will depend upon the cost efficiency of endoscopic practice. The onus on endoscopists and health-care providers, therefore, is to meticulously evaluate the necessary steps for safe reutilization of accessories. This paper addresses the principles of reuse, quality assurance and particularly disinfection practices. Any change to a more costly disposable accessory policy must bear the responsibility of denied access to endoscopic services in a system with finite resources.

  6. Manganese Content Control in Weld Metal During MAG Welding

    NASA Astrophysics Data System (ADS)

    Chinakhov, D. A.; Chinakhova, E. D.; Sapozhkov, A. S.

    2016-08-01

    The influence of the welding current and method of gas shielding in MAG welding on the content of manganese is considered in the paper. Results of study of the welded specimens of steels 45 when applying welding wire of different formulas and different types of gas shielding (traditional shielding and double-jet shielding) are given. It is found that in MAG welding the value of the welding current and the speed of the gas flow from the welding nozzle have a considerable impact on the chemical composition of the weld metal. The consumable electrode welding under double-jet gas shielding provides the directed gas-dynamics in the welding area and enables controlling the electrode metal transfer and the chemical composition of a weld.

  7. MAG ONE novel energy storage for high tech sports car

    SciTech Connect

    Siuru, B.

    1993-03-01

    A solar-powered car, the MAG ONE, is discussed. Photovoltaic cells would cover 100 square feet of the car`s body. Solar cells would cover the entire vehicle to intake as much solar energy as possible. By using computerized series-parallel switching of the solar cell system should yield 2-3 horsepower per-hour on a sunny day. An important concept is the proprietary continuously variable hydrostatic transmission capable of 90 percent efficiency.

  8. Design of MagLIF experiments using the Z facility

    NASA Astrophysics Data System (ADS)

    Sefkow, Adam

    2013-10-01

    The MagLIF (Magnetized Liner Inertial Fusion) concept has been presented as a path toward obtaining substantial fusion yields using the Z facility, and related experiments have begun in earnest at Sandia National Laboratories. We present fully integrated numerical magnetohydrodynamic simulations of the MagLIF concept, which include laser preheating of the fuel, the presence of electrodes, and end loss effects. These simulations have been used to design neutron-producing integrated MagLIF experiments on the Z facility for the capabilities that presently exist, namely, D2 fuel, peak currents of Imax 15-18 MA, pre-seeded axial magnetic fields of Bz0 = 7-10 T, and laser preheat energies of Elaser = 2-3 kJ delivered in 2 ns. The first fully integrated experiments, based on these simulations, are planned to occur in 2013. Neutron yields in excess of 1011 are predicted with the available laser preheat energy and accelerator drive energy. In several years, we plan to upgrade the laser to increase Elaser = by several more kJ, provide Bz0 up to 30 T, deliver Imax 22 MA or more to the load, and develop the capability to use DT fuel. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  9. [Accessory symptomatology and therapy of Gilles de la Tourette's disease].

    PubMed

    Achkova, M; Terziev, D

    1987-01-01

    Eight patients with Gilles de la Tourette's syndrome were examined. They had typical multiple tics and accessory disturbances--impulsive and reactive symptoms. The authors described the classification of accessory symptoms and the therapeutic approaches.

  10. 75 FR 76962 - Application To Export Electric Energy; MAG Energy Solutions, Inc.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-10

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF ENERGY Application To Export Electric Energy; MAG Energy Solutions, Inc. AGENCY: Office of Electricity Delivery and Energy Reliability, DOE. ACTION: Notice of Application. SUMMARY: MAG Energy Solutions, Inc. (MAG...

  11. Electronic Position Sensor for Power Operated Accessory

    DOEpatents

    Haag, Ronald H.; Chia, Michael I.

    2005-05-31

    An electronic position sensor for use with a power operated vehicle accessory, such as a power liftgate. The position sensor includes an elongated resistive circuit that is mounted such that it is stationary and extends along the path of a track portion of the power operated accessory. The position sensor further includes a contact nub mounted to a link member that moves within the track portion such that the contact nub is slidingly biased against the elongated circuit. As the link member moves under the force of a motor-driven output gear, the contact nub slides along the surface of the resistive circuit, thereby affecting the overall resistance of the circuit. The position sensor uses the overall resistance to provide an electronic position signal to an ECU, wherein the signal is indicative of the absolute position of the power operated accessory. Accordingly, the electronic position sensor is capable of providing an electronic signal that enables the ECU to track the absolute position of the power operated accessory.

  12. Biting palsy of the accessory nerve.

    PubMed Central

    Paljärvi, L; Partanen, J

    1980-01-01

    A young man was bitten by his girl friend at the anterior border of the left trapezius muscle. Weakness of the trapezius resulted and a longstanding ache in the shoulder developed. Clinically and neurophysiologically, an axonotmesis type crush injury of the accessory nerve was verified. PMID:7431036

  13. 14 CFR 29.1163 - Powerplant accessories.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or... be a hazard if they malfunction, there must be means to prevent their hazardous rotation...

  14. 14 CFR 29.1163 - Powerplant accessories.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... involved; (2) Use the provisions on the engine for mounting; and (3) Be sealed in such a way as to prevent contamination of the engine oil system and the accessory system. (b) Electrical equipment subject to arcing or... be a hazard if they malfunction, there must be means to prevent their hazardous rotation...

  15. Normal variants of the accessory hemiazygos vein

    PubMed Central

    Blackmon, J M; Franco, A

    2011-01-01

    This short communication describes two normal variants of the accessory hemiazygous vein in a 15-year-old female. The article demonstrates that knowledge of the aberrant venous anatomy and the collateral pathway is important for the practising radiologist. PMID:21697414

  16. 21 CFR 890.3910 - Wheelchair accessory.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Wheelchair accessory. 890.3910 Section 890.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3910...

  17. 21 CFR 890.3910 - Wheelchair accessory.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wheelchair accessory. 890.3910 Section 890.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3910...

  18. 21 CFR 890.3910 - Wheelchair accessory.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Wheelchair accessory. 890.3910 Section 890.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3910...

  19. 21 CFR 890.3910 - Wheelchair accessory.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Wheelchair accessory. 890.3910 Section 890.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3910...

  20. 21 CFR 890.3910 - Wheelchair accessory.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Wheelchair accessory. 890.3910 Section 890.3910 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3910...

  1. Salivary gland tumors

    MedlinePlus

    ... glands are located around the mouth. They produce saliva, which moistens food to help with chewing and ... the rest of the mouth. Salivary glands empty saliva into the mouth through ducts that open at ...

  2. Pituitary Gland Disorders Overview

    MedlinePlus

    ... y Cuidadores Hormones and Health Journey Through the Endocrine System Endocrine Disrupting Chemicals (EDCs) Endocrine Glands and Types ... Women's Health Hormones and Health Journey Through the Endocrine System Endocrine Disrupting Chemicals (EDCs) Endocrine Glands and Types ...

  3. Adrenal Gland Cancer

    MedlinePlus

    ... either benign or malignant. Benign tumors aren't cancer. Malignant ones are. Most adrenal gland tumors are ... and may not require treatment. Malignant adrenal gland cancers are uncommon. Types of tumors include Adrenocortical carcinoma - ...

  4. 21 CFR 868.5860 - Pressure tubing and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pressure tubing and accessories. 868.5860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5860 Pressure tubing and accessories. (a) Identification. Pressure tubing and accessories are flexible or rigid devices intended...

  5. 21 CFR 868.5860 - Pressure tubing and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pressure tubing and accessories. 868.5860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5860 Pressure tubing and accessories. (a) Identification. Pressure tubing and accessories are flexible or rigid devices intended...

  6. 21 CFR 868.5860 - Pressure tubing and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pressure tubing and accessories. 868.5860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5860 Pressure tubing and accessories. (a) Identification. Pressure tubing and accessories are flexible or rigid devices intended...

  7. 14 CFR 23.1192 - Engine accessory compartment diaphragm.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Engine accessory compartment diaphragm. 23... Powerplant Powerplant Fire Protection § 23.1192 Engine accessory compartment diaphragm. For aircooled radial... accessory compartment by a diaphragm that meets the firewall requirements of § 23.1191....

  8. 14 CFR 23.1192 - Engine accessory compartment diaphragm.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine accessory compartment diaphragm. 23... Powerplant Powerplant Fire Protection § 23.1192 Engine accessory compartment diaphragm. For aircooled radial... accessory compartment by a diaphragm that meets the firewall requirements of § 23.1191....

  9. 14 CFR 25.1192 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Engine accessory section diaphragm. 25.1192....1192 Engine accessory section diaphragm. For reciprocating engines, the engine power section and all portions of the exhaust system must be isolated from the engine accessory compartment by a diaphragm...

  10. 14 CFR 23.1192 - Engine accessory compartment diaphragm.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Engine accessory compartment diaphragm. 23... Powerplant Powerplant Fire Protection § 23.1192 Engine accessory compartment diaphragm. For aircooled radial... accessory compartment by a diaphragm that meets the firewall requirements of § 23.1191....

  11. 14 CFR 25.1192 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Engine accessory section diaphragm. 25.1192....1192 Engine accessory section diaphragm. For reciprocating engines, the engine power section and all portions of the exhaust system must be isolated from the engine accessory compartment by a diaphragm...

  12. 14 CFR 25.1192 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Engine accessory section diaphragm. 25.1192....1192 Engine accessory section diaphragm. For reciprocating engines, the engine power section and all portions of the exhaust system must be isolated from the engine accessory compartment by a diaphragm...

  13. 14 CFR 23.1192 - Engine accessory compartment diaphragm.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Engine accessory compartment diaphragm. 23... Powerplant Powerplant Fire Protection § 23.1192 Engine accessory compartment diaphragm. For aircooled radial... accessory compartment by a diaphragm that meets the firewall requirements of § 23.1191....

  14. 14 CFR 25.1192 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Engine accessory section diaphragm. 25.1192....1192 Engine accessory section diaphragm. For reciprocating engines, the engine power section and all portions of the exhaust system must be isolated from the engine accessory compartment by a diaphragm...

  15. 21 CFR 876.5540 - Blood access device and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood access device and accessories. 876.5540... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5540 Blood access device and accessories. (a) Identification. A blood access device and accessories is a device intended...

  16. 21 CFR 876.5540 - Blood access device and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood access device and accessories. 876.5540... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5540 Blood access device and accessories. (a) Identification. A blood access device and accessories is a device intended...

  17. 21 CFR 876.5540 - Blood access device and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood access device and accessories. 876.5540... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5540 Blood access device and accessories. (a) Identification. A blood access device and accessories is a device intended...

  18. 21 CFR 876.5540 - Blood access device and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood access device and accessories. 876.5540... (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5540 Blood access device and accessories. (a) Identification. A blood access device and accessories is a device intended...

  19. 14 CFR 25.1192 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Engine accessory section diaphragm. 25.1192....1192 Engine accessory section diaphragm. For reciprocating engines, the engine power section and all portions of the exhaust system must be isolated from the engine accessory compartment by a diaphragm...

  20. 21 CFR 872.6300 - Rubber dam and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rubber dam and accessories. 872.6300 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6300 Rubber dam and accessories. (a) Identification. A rubber dam and accessories is a device composed of a thin sheet of latex with a hole in...

  1. 21 CFR 872.6300 - Rubber dam and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Rubber dam and accessories. 872.6300 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6300 Rubber dam and accessories. (a) Identification. A rubber dam and accessories is a device composed of a thin sheet of latex with a hole in...

  2. 19 CFR 10.1020 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Accessories, spare parts, or tools. 10.1020... Free Trade Agreement Rules of Origin § 10.1020 Accessories, spare parts, or tools. (a) General. Accessories, spare parts, or tools that are delivered with a good and that form part of the good's...

  3. 19 CFR 10.3020 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Accessories, spare parts, or tools. 10.3020...-Colombia Trade Promotion Agreement Rules of Origin § 10.3020 Accessories, spare parts, or tools. (a) General. Accessories, spare parts, or tools that are delivered with a good and that form part of the...

  4. 19 CFR 10.600 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 1 2012-04-01 2012-04-01 false Accessories, spare parts, or tools. 10.600 Section...-Central America-United States Free Trade Agreement Rules of Origin § 10.600 Accessories, spare parts, or tools. (a) General. Accessories, spare parts, or tools that are delivered with a good and that form...

  5. 19 CFR 10.3020 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 1 2013-04-01 2013-04-01 false Accessories, spare parts, or tools. 10.3020...-Colombia Trade Promotion Agreement Rules of Origin § 10.3020 Accessories, spare parts, or tools. (a) General. Accessories, spare parts, or tools that are delivered with a good and that form part of the...

  6. 19 CFR 10.2020 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Accessories, spare parts, or tools. 10.2020... Trade Promotion Agreement Rules of Origin § 10.2020 Accessories, spare parts, or tools. (a) General. Accessories, spare parts, or tools that are delivered with a good and that form part of the good's...

  7. 19 CFR 10.600 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 1 2013-04-01 2013-04-01 false Accessories, spare parts, or tools. 10.600 Section...-Central America-United States Free Trade Agreement Rules of Origin § 10.600 Accessories, spare parts, or tools. (a) General. Accessories, spare parts, or tools that are delivered with a good and that form...

  8. 19 CFR 10.1020 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 1 2012-04-01 2012-04-01 false Accessories, spare parts, or tools. 10.1020... Free Trade Agreement Rules of Origin § 10.1020 Accessories, spare parts, or tools. (a) General. Accessories, spare parts, or tools that are delivered with a good and that form part of the good's...

  9. 19 CFR 10.600 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 1 2011-04-01 2011-04-01 false Accessories, spare parts, or tools. 10.600 Section...-Central America-United States Free Trade Agreement Rules of Origin § 10.600 Accessories, spare parts, or tools. (a) General. Accessories, spare parts, or tools that are delivered with a good and that form...

  10. 19 CFR 10.1020 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 1 2013-04-01 2013-04-01 false Accessories, spare parts, or tools. 10.1020... Free Trade Agreement Rules of Origin § 10.1020 Accessories, spare parts, or tools. (a) General. Accessories, spare parts, or tools that are delivered with a good and that form part of the good's...

  11. 19 CFR 10.600 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Accessories, spare parts, or tools. 10.600 Section...-Central America-United States Free Trade Agreement Rules of Origin § 10.600 Accessories, spare parts, or tools. (a) General. Accessories, spare parts, or tools that are delivered with a good and that form...

  12. 19 CFR 10.600 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Accessories, spare parts, or tools. 10.600 Section...-Central America-United States Free Trade Agreement Rules of Origin § 10.600 Accessories, spare parts, or tools. (a) General. Accessories, spare parts, or tools that are delivered with a good and that form...

  13. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended...

  14. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended...

  15. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended...

  16. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended...

  17. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended...

  18. 21 CFR 872.6010 - Abrasive device and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Abrasive device and accessories. 872.6010 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories. (a) Identification. An abrasive device and accessories is a device constructed of various...

  19. 21 CFR 872.6010 - Abrasive device and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Abrasive device and accessories. 872.6010 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories. (a) Identification. An abrasive device and accessories is a device constructed of various...

  20. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices...

  1. 21 CFR 872.4920 - Dental electrosurgical unit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental electrosurgical unit and accessories. 872... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4920 Dental electrosurgical unit and accessories. (a) Identification. A dental electrosurgical unit and accessories is an...

  2. 21 CFR 872.4200 - Dental handpiece and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or...

  3. 21 CFR 872.6250 - Dental chair and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits....

  4. 21 CFR 872.6640 - Dental operative unit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that...

  5. 21 CFR 872.6250 - Dental chair and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits....

  6. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices...

  7. 21 CFR 872.4200 - Dental handpiece and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or...

  8. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices...

  9. 21 CFR 872.4200 - Dental handpiece and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or...

  10. 21 CFR 872.4200 - Dental handpiece and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or...

  11. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices...

  12. 21 CFR 872.4200 - Dental handpiece and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental handpiece and accessories. 872.4200 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4200 Dental handpiece and accessories. (a) Identification. A dental handpiece and accessories is an AC-powered, water-powered, air-powered, or...

  13. 21 CFR 872.3980 - Endosseous dental implant accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endosseous dental implant accessories. 872.3980... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3980 Endosseous dental implant accessories. (a) Identification. Endosseous dental implant accessories are manually powered devices...

  14. 21 CFR 872.6640 - Dental operative unit and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that...

  15. 21 CFR 872.6250 - Dental chair and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits....

  16. 21 CFR 872.6250 - Dental chair and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits....

  17. 21 CFR 872.6640 - Dental operative unit and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that...

  18. 21 CFR 872.6640 - Dental operative unit and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Dental operative unit and accessories. 872.6640... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6640 Dental operative unit and accessories. (a) Identification. A dental operative unit and accessories is an AC-powered device that...

  19. 21 CFR 872.6250 - Dental chair and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Dental chair and accessories. 872.6250 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6250 Dental chair and accessories. (a) Identification. A dental chair and accessories is a device, usually AC-powered, in which a patient sits....

  20. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for...

  1. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for...

  2. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for...

  3. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for...

  4. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for...

  5. 21 CFR 878.4700 - Surgical microscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Surgical microscope and accessories. 878.4700 Section 878.4700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... microscope and accessories. (a) Identification. A surgical microscope and accessories is an AC-powered...

  6. 21 CFR 878.4700 - Surgical microscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Surgical microscope and accessories. 878.4700 Section 878.4700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... microscope and accessories. (a) Identification. A surgical microscope and accessories is an AC-powered...

  7. 21 CFR 878.4700 - Surgical microscope and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Surgical microscope and accessories. 878.4700 Section 878.4700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... microscope and accessories. (a) Identification. A surgical microscope and accessories is an AC-powered...

  8. Detection of accessory spleens with indium 111-labeled autologous platelets

    SciTech Connect

    Davis, H.H., II; Varki, A.; Heaton, W.A.; Siegel, B.A.

    1980-01-01

    In two patients with recurrent immune thrombocytopenia, accessory splenic tissue was demonstrated by radionuclide imaging following administration of indium 111-labeled autologous platelets. In one of these patients, no accessory splenic tissue was seen on images obtained with technetium 99m sulfur colloid. This new technique provides a simple means for demonstrating accessory spleens and simultaneously evaluating the life-span of autologous platelets.

  9. 21 CFR 884.6120 - Assisted reproduction accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Assisted reproduction accessories. 884.6120... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6120 Assisted reproduction accessories. (a) Identification. Assisted reproduction accessories are a group...

  10. 21 CFR 884.6120 - Assisted reproduction accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Assisted reproduction accessories. 884.6120... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6120 Assisted reproduction accessories. (a) Identification. Assisted reproduction accessories are a group...

  11. 21 CFR 884.6120 - Assisted reproduction accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Assisted reproduction accessories. 884.6120... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6120 Assisted reproduction accessories. (a) Identification. Assisted reproduction accessories are a group...

  12. 21 CFR 884.6120 - Assisted reproduction accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Assisted reproduction accessories. 884.6120... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction Devices § 884.6120 Assisted reproduction accessories. (a) Identification. Assisted reproduction accessories are a group...

  13. 21 CFR 876.5980 - Gastrointestinal tube and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gastrointestinal tube and accessories. 876.5980... tube and accessories. (a) Identification. A gastrointestinal tube and accessories is a device that..., gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression...

  14. 21 CFR 876.5980 - Gastrointestinal tube and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gastrointestinal tube and accessories. 876.5980... tube and accessories. (a) Identification. A gastrointestinal tube and accessories is a device that..., gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression...

  15. 21 CFR 876.5980 - Gastrointestinal tube and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastrointestinal tube and accessories. 876.5980... tube and accessories. (a) Identification. A gastrointestinal tube and accessories is a device that..., gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression...

  16. 21 CFR 876.5980 - Gastrointestinal tube and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gastrointestinal tube and accessories. 876.5980... tube and accessories. (a) Identification. A gastrointestinal tube and accessories is a device that..., gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression...

  17. 21 CFR 876.5980 - Gastrointestinal tube and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gastrointestinal tube and accessories. 876.5980... tube and accessories. (a) Identification. A gastrointestinal tube and accessories is a device that..., gastrointestinal string and tubes to locate internal bleeding, double lumen tube for intestinal decompression...

  18. 21 CFR 878.4700 - Surgical microscope and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical microscope and accessories. 878.4700 Section 878.4700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... microscope and accessories. (a) Identification. A surgical microscope and accessories is an AC-powered...

  19. 21 CFR 878.4700 - Surgical microscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Surgical microscope and accessories. 878.4700 Section 878.4700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... microscope and accessories. (a) Identification. A surgical microscope and accessories is an AC-powered...

  20. Submandibular gland myoepithelioma.

    PubMed

    Testa, D; Galera, F; Insabato, L; Vassallo, A; Mesolella, M; Galli, V

    2005-06-01

    Benign myoepithelioma is a very rare form of salivary gland tumor, composed entirely of myoepithelial cells. It accounts for approximately 1% of all salivary gland tumors and is most frequently located in the parotid gland and in the minor salivary glands of the hard palate. We describe herein the ninth reported case of myoepithelioma of the submandibular gland. Benign myoepithelioma must be differentiated from several benign and malignant epithelial and mesenchymal tumors. Immunohistochemical staining can help differentiate between these conditions, but histopathology remains the gold standard for diagnosing this neoplastic process.

  1. Secretory and basal cells of the epithelium of the tubular glands in the male Mullerian gland of the caecilian Uraeotyphlus narayani (Amphibia: Gymnophiona).

    PubMed

    George, Jancy M; Smita, Matthew; Kadalmani, Balamuthu; Girija, Ramankutty; Oommen, Oommen V; Akbarsha, Mohammad A

    2004-12-01

    Caecilians are exceptional among the vertebrates in that males retain the Mullerian duct as a functional glandular structure. The Mullerian gland on each side is formed from a large number of tubular glands connecting to a central duct, which either connects to the urogenital duct or opens directly into the cloaca. The Mullerian gland is believed to secrete a substance to be added to the sperm during ejaculation. Thus, the Mullerian gland could function as a male accessory reproductive gland. Recently, we described the male Mullerian gland of Uraeotyphlus narayani using light and transmission electron microscopy (TEM) and histochemistry. The present TEM study reports that the secretory cells of both the tubular and basal portions of the tubular glands of the male Mullerian gland of this caecilian produce secretion granules in the same manner as do other glandular epithelial cells. The secretion granules are released in the form of structured granules into the lumen of the tubular glands, and such granules are traceable to the lumen of the central duct of the Mullerian gland. This is comparable to the situation prevailing in the epididymal epithelium of several reptiles. In the secretory cells of the basal portion of the tubular glands, mitochondria are intimately associated with fabrication of the secretion granules. The structural and functional organization of the epithelium of the basal portion of the tubular glands is complicated by the presence of basal cells. This study suggests the origin of the basal cells from peritubular tissue leukocytes. The study also indicates a role for the basal cells in acquiring secretion granules from the neighboring secretory cells and processing them into lipofuscin material in the context of regression of the Mullerian gland during the period of reproductive quiescence. In these respects the basal cells match those in the epithelial lining of the epididymis of amniotes.

  2. Secretory and basal cells of the epithelium of the tubular glands in the male Mullerian gland of the caecilian Uraeotyphlus narayani (Amphibia: Gymnophiona).

    PubMed

    George, Jancy M; Smita, Matthew; Kadalmani, Balamuthu; Girija, Ramankutty; Oommen, Oommen V; Akbarsha, Mohammad A

    2004-12-01

    Caecilians are exceptional among the vertebrates in that males retain the Mullerian duct as a functional glandular structure. The Mullerian gland on each side is formed from a large number of tubular glands connecting to a central duct, which either connects to the urogenital duct or opens directly into the cloaca. The Mullerian gland is believed to secrete a substance to be added to the sperm during ejaculation. Thus, the Mullerian gland could function as a male accessory reproductive gland. Recently, we described the male Mullerian gland of Uraeotyphlus narayani using light and transmission electron microscopy (TEM) and histochemistry. The present TEM study reports that the secretory cells of both the tubular and basal portions of the tubular glands of the male Mullerian gland of this caecilian produce secretion granules in the same manner as do other glandular epithelial cells. The secretion granules are released in the form of structured granules into the lumen of the tubular glands, and such granules are traceable to the lumen of the central duct of the Mullerian gland. This is comparable to the situation prevailing in the epididymal epithelium of several reptiles. In the secretory cells of the basal portion of the tubular glands, mitochondria are intimately associated with fabrication of the secretion granules. The structural and functional organization of the epithelium of the basal portion of the tubular glands is complicated by the presence of basal cells. This study suggests the origin of the basal cells from peritubular tissue leukocytes. The study also indicates a role for the basal cells in acquiring secretion granules from the neighboring secretory cells and processing them into lipofuscin material in the context of regression of the Mullerian gland during the period of reproductive quiescence. In these respects the basal cells match those in the epithelial lining of the epididymis of amniotes. PMID:15487004

  3. [Accessory renal arteries in human fetuses].

    PubMed

    Gościcka, D; Szpinda, M; Kochan, J

    1996-12-01

    Using conventional anatomical methods, renal arteries of 140 human fetuses were studied. It was found (21.1%) that the accessory renal arteries occurred in a three-fold manner: 1. as single arteries (19.2%), 2. as double arteries (2.1%) and 3. as triplex arteries (0.7%). More often they originated from the right part of the circumference of the abdominal aorta, mainly in the female fetuses. These arteries penetrated the following segments of the kidney: the inferior (12.9%), the superior (2.3%), the anterior inferior (2.8%), the posterior (2.1%) and the anterior superior (1.5%). They crossed the renal pelvis more often in front (12.2%) than from behind of it (5%). The frequency of the occurrence of the accessory arteries depends not from the age of the fetus. PMID:9082875

  4. MAG*SEP{sup SM} process technology demonstration at SRS

    SciTech Connect

    Sliger, E.K.; Wilkey, M.L.

    1996-12-31

    Selective Environmental Technologies, Inc. (Selentec) has been involved in laboratory and pilot scale demonstration testing of its patented MAG*SEP{sup SM} technology. This technology is being considered for eventual application at sites involving groundwater contaminated with heavy metals and/or radionuclides. A prototype scale demonstration test of the MAG*SEP{sup SM} technology has shown that the process is capable of removal of heavy metal contaminants in the presence of significant concentrations of competing ions. For example, nickel ion concentrations were reduced from approximately 1000 ppb to less than 100 ppb in the presence of significant concentrations of competing ions, specifically aluminum (50 ppm), magnesium (40 ppm), and calcium (60 ppm). This work has been carried out with a project team consisting of Selentec, B&W Nuclear Technologies (magnetic filter supplier), RUST Environment and Infrastructure (design support), Argonne National Laboratory (contract management), and Westinghouse Savannah River Company (site support). Laboratory testing and analytical support were provided by the Savannah River Technology Center (SRTC) and the pilot scale demonstration was carried out at the Savannah River Site D Area Coal Pile Runoff Basin.

  5. Laser heating challenges of high yield MagLIF targets

    NASA Astrophysics Data System (ADS)

    Slutz, Stephen; Sefkow, Adam; Vesey, Roger

    2014-10-01

    The MagLIF (Magnetized Liner Inertial Fusion) concept is predicted by numerical simulation to produce fusion yields of about 100 kJ, when driven by 25 MA from the existing Z accelerator [S. A. Slutz et al. Phys. Plasmas 17, 056303 (2010)] and much higher yields with future accelerators delivering higher currents [Slutz and Vesey PRL 108, 025003 (2012)]. The fuel must be heated before compression to obtain significant fusion yields due to the relatively slow implosion velocities (~ 100 km/s) of magnetically driven liners. Lasers provide a convenient means to accomplish this pre-compressional heating of the fusion fuel, but there are challenges. The laser must penetrate a foil covering the laser entrance hole and deposit 20-30 kJ within the ~1 cm length of the liner in fuel at 6-12 mg/cc. Such high densities could result in beam scattering due to refraction and laser plasma interactions. Numerical simulations of the laser heating process are presented, which indicate that energies as high as 30 kJ could be deposited in the fuel by using two laser pulses of different wavelengths. Simulations of this process will be presented as well of results for a MagLIF design for a potential new machine delivering 50 MA of current. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under Contract DE-AC04-94AL85000.

  6. Histological changes in male accessory reproductive organs in rats exposed to cigarette smoke and the protective effect of honey supplementation.

    PubMed

    Mohamed, Mahaneem; Sulaiman, Siti Amrah; Jaafar, Hasnan

    2012-01-01

    The effect of cigarette smoke (CS) on histology of male accessory reproductive organs and the possible protective effect of honey supplementation in rats were investigated in this study. Rats received distilled water, honey, CS exposure or honey plus CS exposure. Honey (1.2 g/kg body weight/day) was administered by gavage and CS exposure (3 times per day) was done in a chamber for 13 weeks. CS exposure significantly increased relative weight of epididymis and ventral prostate. There were also significantly increased number of clear cells and epithelial height of cauda epididymis as well as severe interstitial oedema and decreased epithelial height of prostate gland. However, with the supplementation of honey, these histological changes were significantly reversed suggesting the protective effect of honey against the toxic effect of CS on male accessory reproductive organs in rats.

  7. Salivary gland disorders.

    PubMed

    Mandel, Louis

    2014-11-01

    Patients with salivary gland disease present with certain objective and/or subjective signs. An accurate diagnosis for these patients requires a range of techniques that includes the organized integration of information derived from their history, clinical examination, imaging, serology, and histopathology. This article highlights the signs and symptoms of the salivary gland disorders seen in the Salivary Gland Center, and emphasizes the methodology used to achieve a definitive diagnosis and therapy.

  8. Submandibular gland excision.

    PubMed

    Crabtree, G M; Yarington, C T

    1988-10-01

    A review of 107 submandibular gland excisions was made to determine the relative frequency of neoplastic versus non-neoplastic disease. The results show a preponderance of non-neoplastic pathology. Benign tumors were found in 6% of glands, primary glandular and metastatic carcinoma in 3%. Timely treatment of a submandibular gland mass is indicated due to the relatively aggressive behavior of malignancies originating in this location.

  9. New recombinant chimeric antigens, P35-MAG1, MIC1-ROP1, and MAG1-ROP1, for the serodiagnosis of human toxoplasmosis.

    PubMed

    Drapała, Dorota; Holec-Gąsior, Lucyna; Kur, Józef

    2015-05-01

    The aim of the study was to evaluate the usefulness of 3 chimeric Toxoplasma gondii antigens, P35-MAG1, MIC1-ROP1 and MAG1-ROP1, in the serodiagnosis of an acute toxoplasmosis in humans. Proteins were produced as fusion proteins containing His tags ends and then further purified by metal affinity chromatography. Their application for the diagnosis of recently acquired T. gondii infection was tested in IgG and IgM enzyme-linked immunosorbent assays (ELISAs). At 100%, 77.3%, and 86.4%, respectively, the reactivity of the IgG ELISA using P35-MAG1, MIC1-ROP1, and MAG1-ROP1 for sera from patients where acute toxoplasmosis was suspected was significantly higher than for the samples from people with a chronic infection, at 26.2%, 36.1%, and 32.8%, respectively. Moreover, P35-MAG1, MIC1-ROP1, and MAG1-ROP1 detected IgM antibodies with a reactivity at 81.8%, 72.7%, and 59.1%, respectively. The results presented in the article show that, particularly, P35-MAG1 may be useful in the preliminary detection of recent T. gondii infection.

  10. MAG-GATE System for Molten metal Flow Control

    SciTech Connect

    Richard D. Nathenson, P.E.

    2004-05-15

    The need for improved active flow control has been recognized as part of the Steel Industry Technology Roadmap. Under TRP 9808 for the American Iron and Steel Institute and the Department of Energy, Concept Engineering Group Inc. has developed MAG-GATE{trademark}, an electromagnetic system for active molten metal flow control. Two hot steel tests were successfully conducted in 2003 at the Whemco Foundry Division, Midland, PA. Approximately 110,000 pounds of 0.2% carbon steel were poured through the device subject to electromagnetic flow control. Excellent agreement between predicted and actual flow control was found. A survey of the molten metal flow control practices at 100 continuous casters in North America was also conducted in 2003. This report summarizes the results of the development program to date. Preliminary designs are described for the next step of a beta test at an operating billet/bloom or slab caster.

  11. Experimental investigations of the arc MIG-MAG welding

    SciTech Connect

    Pellerin, N.; Zielinska, S.; Briand, F.; Richard, F.

    2006-01-15

    The type of the applied shielding gas has a strong influence on quality of the welding process. In particular, increase of the percentage of carbon dioxide in argon, causes increase of the transition current value from the globular to spray mode of metal transfer. Observations by fast camera allows to better characterize the arc column shape in the different working modes. The spectroscopic diagnostic of the welding arc is also necessary to understand the observed changes in the mode of droplet transfer. The use of an original diagnostic method allows to estimate the temperature and the electronic density distributions in the plasma without hypothesis on its equilibrium state. Results of this work seem to show that the observed effects could be linked to the microstructural modifications of the anode tip during the MIG-MAG welding process as a function of the gas composition, and especially to the existence and disappearance of an insulating oxide 'gangue' at the wire extremity.

  12. Experimental investigations of the arc MIG-MAG welding

    NASA Astrophysics Data System (ADS)

    Pellerin, N.; Zielińska, S.; Pellerin, S.; Valensi, F.; Musioł, K.; de Izarra, Ch.; Briand, F.; Richard, F.

    2006-01-01

    The type of the applied shielding gas has a strong influence on quality of the welding process. In particular, increase of the percentage of carbon dioxide in argon, causes increase of the transition current value from the globular to spray mode of metal transfer. Observations by fast camera allows to better characterize the arc column shape in the different working modes. The spectroscopic diagnostic of the welding arc is also necessary to understand the observed changes in the mode of droplet transfer. The use of an original diagnostic method allows to estimate the temperature and the electronic density distributions in the plasma without hypothesis on its equilibrium state. Results of this work seem to show that the observed effects could be linked to the microstructural modifications of the anode tip during the MIG-MAG welding process as a function of the gas composition, and especially to the existence and disappearance of an insulating oxide "gangue" at the wire extremity.

  13. Meibomian gland dysfunction.

    PubMed

    Driver, P J; Lemp, M A

    1996-01-01

    Blepharitis is probably the most common disease entity seen in the general ophthalmologist's office. A significant proportion of these cases are secondary to meibomian gland disease. This review outlines our knowledge of the histopathology, lipid abnormalities and role of microorganisms in meibomian gland dysfunction. We will also review the physiology of meibomian gland secretion and present models of meibomian gland dysfunction which have enhanced our knowledge of this condition. The importance of diagnosing associated conditions such as aqueous tear deficiency, contact lens intolerance, rosacea, and seborrheic dermatitis is emphasized. Although this condition causes significant morbidity in the population, there are effective treatments available and these will be discussed.

  14. "Lights on at the end of the party": are lads' mags mainstreaming dangerous sexism?

    PubMed

    Horvath, Miranda A H; Hegarty, Peter; Tyler, Suzannah; Mansfield, Sophie

    2012-11-01

    Research has suggested that some magazines targeted at young men - lads' mags - are normalizing extreme sexist views by presenting those views in a mainstream context. Consistent with this view, young men in Study 1 (n = 90) identified more with derogatory quotes about women drawn from recent lads' mags, and from interviews with convicted rapists, when those quotes were attributed to lads' mags, than when they were attributed to convicted rapists. In Study 2, 40 young women and men could not reliably judge the source of those same quotes. While these participants sometimes voiced the belief that the content of lads' mags was 'normal' while rapists' talk was 'extreme', they categorized quotes from both sources as derogatory with equal frequency. Jointly, the two studies show an overlap in the content of convicted rapists' talk and the contents of contemporary lads' mags, and suggest that the framing of such content within lads' mags may normalize it for young men.

  15. An unusual cause of subtalar pain and instability: accessory calcaneus.

    PubMed

    Boulet, C; De Maeseneer, M; Everaert, H; Kichouh, M; De Mey, J; Shahabpour, M

    2012-01-01

    We report on a 45-yr-old male sports instructor with chronic pain and instability of the ankle. He was a recreational basketball player, but because of repeated ankle sprains and chronic subtalar pain this activity became impossible. The radiologic findings were compatible with the diagnosis of accessory calcaneus. In an initial therapeutic approach the patient was treated conservatively with taping and physical therapy, but this failed to relieve the symptoms. Next, a ligamentoplasty was performed. The instability improved, but the pain remained the same. Finally the accessory calcaneus was resected and short term follow-up was unremarkable. Accessory calcaneus is an uncommon anatomical variation that may cause subtalar pain and instability. Resection of the accessory bone may be necessary to provide relief of symptoms. Accessory calcaneus can be well demonstrated on CT, SPECT-CT, and MR. MR and nuclear medicine can indicate instability of the accessory bone by showing bone marrow edema on MR or uptake on fusion imaging.

  16. Accessory sperm: a biomonitor of boar sperm fertilization capacity.

    PubMed

    Ardón, Florencia; Evert, Meike; Beyerbach, Martin; Weitze, Karl-Fritz; Waberski, Dagmar

    2005-04-15

    The number of accessory sperm found in the zona pellucida of porcine embryos was correlated to their individual quality and to the embryo quality range found within a single sow. Our goal was to determine whether accessory sperm counts provide semen evaluation with additional, useful information. Accessory sperm count was highest when only normal embryos were found in a given sow and diminished if oocytes or degenerated embryos were present (P<0.01). Within a given sow, normal embryos had higher (P<0.05) accessory sperm counts than degenerated embryos, although not when oocytes were also present. Fertilization capacity of sperm is optimal when only normal embryos are found in a given sow; this capacity is indicated by high accessory sperm counts. A decrease in fertilization capacity is reflected in diminishing accessory sperm counts. The boar had a significant effect (P<0.01) on accessory sperm count, but not on the percentage of normal embryos; this suggests that accessory sperm may be more sensitive indicators of the fertilization capacity of sperm than the percentage of normal embryos. We conclude that accessory sperm count can be used for the detection of compensable defects in sperm and is a valid parameter for assessing sperm fertilization capacity.

  17. 21 CFR 884.1690 - Hysteroscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Diagnostic Devices... portals for electrosurgical, laser, or other power sources. Such hysteroscope accessory...

  18. Thyroid gland biopsy (image)

    MedlinePlus

    The thyroid is a gland located in the neck. It is a part of the endocrine (hormone) system, and plays a major role in regulating ... sample of cells is needed from the thyroid gland a fine needle biopsy can be performed. During ...

  19. Salivary Gland Secretion.

    ERIC Educational Resources Information Center

    Dorman, H. L.; And Others

    1981-01-01

    Describes materials and procedures for an experiment utilizing a live dog to demonstrate: (1) physiology of the salivary gland; (2) parasympathetic control of the salivary gland; (3) influence of varying salivary flow rates on sodium and potassium ions, osmolarity and pH; and (4) salivary secretion as an active process. (DS)

  20. Salivary Gland Cancer

    MedlinePlus

    ... contains antibodies that can kill germs. Salivary gland cancer is a type of head and neck cancer. It is rare. It may not cause any ... pain in your face Doctors diagnose salivary gland cancer using a physical exam, imaging tests, and a ...

  1. Identity and transfer of male reproductive gland proteins of the dengue vector mosquito, Aedes aegypti: potential tools for control of female feeding and reproduction.

    PubMed

    Sirot, Laura K; Poulson, Rebecca L; McKenna, M Caitlin; Girnary, Hussein; Wolfner, Mariana F; Harrington, Laura C

    2008-02-01

    Male reproductive gland proteins (mRGPs) impact the physiology and/or behavior of mated females in a broad range of organisms. We sought to identify mRGPs of the yellow fever mosquito, Aedes aegypti, the primary vector of dengue and yellow fever viruses. Earlier studies with Ae. aegypti demonstrated that "matrone" (a partially purified male reproductive accessory gland substance) or male accessory gland fluid injected into virgin female Ae. aegypti affect female sexual refractoriness, blood feeding and digestion, flight, ovarian development, and oviposition. Using bioinformatic comparisons to Drosophila melanogaster accessory gland proteins and mass spectrometry of proteins from Ae. aegypti male accessory glands and ejaculatory ducts (AG/ED) and female reproductive tracts, we identified 63 new putative Ae. aegypti mRGPs. Twenty-one of these proteins were found in the reproductive tract of mated females but not of virgin females suggesting that they are transferred from males to females during mating. Most of the putative mRGPs fall into the same protein classes as mRGPs in other organisms, although some appear to be evolving rapidly and lack identifiable homologs in Culex pipiens, Anopheles gambiae, and D. melanogaster. Our results identify candidate male-derived molecules that may have an important influence on behavior, survival, and reproduction of female mosquitoes.

  2. Ultrastructure and cytochemistry of salivary glands of the predator Podisus nigrispinus (Hemiptera: Pentatomidae.

    PubMed

    Martínez, Luis Carlos; Fialho, Maria do Carmo Queiroz; Zanuncio, José Cola; Serrão, José Eduardo

    2014-05-01

    Podisus nigrispinus Dallas (Hemiptera: Pentatomidae) is a zoophytophagous insect with a potential for use as a biological control agent in agriculture because nymphs and adults actively prey on various insects by inserting mouthparts and regurgitating the contents of the salivary glands inside the prey, causing rapid paralysis and death. However, the substances found in saliva of P. nigrispinus that causes the death of the prey are unknown. As a first step to identify the component of the saliva of P. nigrispinus, this study evaluated the ultrastructure and cytochemistry of the salivary glands of P. nigrispinus. The salivary system of P. nigrispinus has a pair of principal salivary glands, which are bilobed with a short anterior lobe and a long posterior lobe, and a pair of tubular accessory glands. The principal gland epithelium is composed of a single layer of cells enclosing a large lumen. Epithelial cells of the principal salivary gland vary from cubic to columnar shape, with one or two spherical and well-developed nuclei. Cells of the anterior lobe of the principal salivary gland have an apical surface with narrow, short, and irregular plasma membrane foldings; apical and perinuclear cytoplasm rich in rough endoplasmic reticulum; and mitochondria with tubular cristae. The basal portion of the secretory cells has mitochondria associated with many basal plasma membrane infoldings that are short but form large extracellular canals. Secretory granules with electron-dense core and electron-transparent peripheral are dispersed throughout the cytoplasm. Cells of the posterior lobe of the principal salivary gland are similar to those of the anterior lobe, except for the presence of mitochondria with transverse cristae. The accessory salivary gland cells are columnar with apical microvilli, have well-developed nucleus and cytoplasm rich in rough endoplasmic reticulum, and have secretory granules. Cytochemical tests showed positive reactions for carbohydrate, protein

  3. Non-productive DNA damage binding by DNA glycosylase-like protein Mag2 from Schizosaccharomyces pombe.

    PubMed

    Adhikary, Suraj; Cato, Marilyn C; McGary, Kriston L; Rokas, Antonis; Eichman, Brandt F

    2013-03-01

    Schizosaccharomyces pombe contains two paralogous proteins, Mag1 and Mag2, related to the helix-hairpin-helix (HhH) superfamily of alkylpurine DNA glycosylases from yeast and bacteria. Phylogenetic analysis of related proteins from four Schizosaccharomyces and other fungal species shows that the Mag1/Mag2 duplication is unique to the genus Schizosaccharomyces and most likely occurred in its ancestor. Mag1 excises N3- and N7-alkylguanines and 1,N(6)-ethenoadenine from DNA, whereas Mag2 has been reported to have no detectible alkylpurine base excision activity despite high sequence and active site similarity to Mag1. To understand this discrepancy we determined the crystal structure of Mag2 bound to abasic DNA and compared it to our previously determined Mag1-DNA structure. In contrast to Mag1, Mag2 does not flip the abasic moiety into the active site or stabilize the DNA strand 5' to the lesion, suggesting that it is incapable of forming a catalytically competent protein-DNA complex. Subtle differences in Mag1 and Mag2 interactions with the DNA duplex illustrate how Mag2 can stall at damage sites without fully engaging the lesion. We tested our structural predictions by mutational analysis of base excision and found a single amino acid responsible at least in part for Mag2's lack of activity. Substitution of Mag2 Asp56, which caps the helix at the base of the DNA intercalation loop, with the corresponding serine residue in Mag1 endows Mag2 with ɛA excision activity comparable to Mag1. This work provides novel insight into the chemical and physical determinants by which the HhH glycosylases engage DNA in a catalytically productive manner. PMID:23273506

  4. Reviewing prescription spending and accessory usage.

    PubMed

    Oxenham, Julie

    This article aims to explore the role of the stoma nurse specialist in the community and how recent initiatives within the NHS have impacted on the roles in stoma care to react to the rising prescription costs in the specialty. The article will explore how the stoma care nurse conducted her prescription reviews within her own clinical commissioning group (CCG). The findings of the reviews will be highlighted by a small case history and a mini audit that reveals that some stoma patients may be using their stoma care accessories inappropriately, which may contribute to the rise in stoma prescription spending. To prevent the incorrect use of stoma appliances it may necessitate an annual review of ostomates (individuals who have a stoma), as the author's reviews revealed that inappropriate usage was particularly commonplace when a patient may have not been reviewed by a stoma care specialist for some considerable amount of time. Initial education of the ostomate and ongoing education of how stoma products work is essential to prevent the misuse of stoma appliances, particularly accessories, as the reviews revealed that often patients were not always aware of how their products worked in practice.

  5. Computed tomographic imaging characteristics of the normal canine lacrimal glands

    PubMed Central

    2014-01-01

    Background The canine lacrimal gland (LG) and accessory lacrimal gland of the third eyelid (TEG) are responsible for production of the aqueous portion of the precorneal tear film. Immune-mediated, toxic, neoplastic, or infectious processes can affect the glands directly or can involve adjacent tissues, with secondary gland involvement. Disease affecting these glands can cause keratoconjunctivitis sicca, corneal ulcers, and loss of vision. Due to their location in the orbit, these small structures are difficult to evaluate and measure, making cross-sectional imaging an important diagnostic tool. The detailed cross-sectional imaging appearance of the LG and TEG in dogs using computed tomography (CT) has not been reported to date. Results Forty-two dogs were imaged, and the length, width, and height were measured and the volume calculated for the LGs & TEGs. The glands were best visualized in contrast-enhanced CT images. The mean volume of the LG was 0.14 cm3 and the TEG was 0.1 cm3. The mean height, width, and length of the LG were, 9.36 mm, 4.29 mm, and 9.35 mm, respectively; the corresponding values for the TEG was 2.02 mm, 9.34 mm, and 7.90 mm. LG and TEG volume were positively correlated with body weight (p < 0.05). Conclusions Contrast-enhanced CT is a valuable tool for noninvasive assessment of canine lacrimal glands. PMID:24886364

  6. Nonlinear Propagation of Mag Waves Through the Transition Region

    NASA Astrophysics Data System (ADS)

    Jatenco-Pereira, V.; Steinolfson, R. S.; Mahajan, S.; Tajima, T.

    1990-11-01

    RESUMEN. Una onda de gravitaci5n magneto acustica (GMA), se inicia en el regimen de alta beta cerca de la basa de fot5sfera solar y es segui- da, usando simulaciones numericas, mientras viaja radialmente a traves de la cromosfera, la regi5n de transici6n y dentro de la corona. Se ha' seleccionado parametros iniciales de manera que la beta resulte menor que uno cerca de la parte alta de la regi6n de transici6n. Nuestro interes maximo se concentra en la cantidad y forma del flujo de energia que puede ser llevada por la onda hasta la corona dados una atm6sfera inicial y amplitud de onda especificas. Segun los estudios a la fecha, el flujo de energ1a termico domina, aumentando linealmente con la ampli tud deonda y resulta de aproximadamente i05 ergs/cm2-s en una amplitud de 0.5. El flujo de energia cinetica siempre permanece despreciable, mientras que el flujo de energia magnetica depende de la orientaci5n inicial del campo. Un modo GMA rapido y casi paralelo, el cual es esen- cialmente un modo MHD en la corona se convierte a un modo rapido modificado y a uno lento, cuando la beta atmosferica disminuye a uno. ABSTRACT: A magneto-acoustic-gravity (MAG) wave is initiated in the high-beta regime near the base of the solar photosphere and followed, using numerical siriiulations, as it travels radially through the chromosphere, the transition region, and into the corona. Initial parameters are selected such that beta becomes less than one near the top of the transition region. Our primary interest is in the amount and form of energy flux that can be carried by the wave train into the corona for a specified initial atmosphere and wave amplitude. For the studies conducted to date, the thermal energy flux dominates, it about linearly with wave amplitude and becomes approximately 10 ergs/cm2-s at an amplitude of 0.5. The kinetic energy flux always remains negligible, while the magnetic energy flux depends on the inLtial field orientation. A nearly parallel fast MAG mode, which

  7. Analysis of substrate specificity of Schizosaccharomyces pombe Mag1 alkylpurine DNA glycosylase

    SciTech Connect

    Adhikary, Suraj; Eichman, Brandt F.

    2014-10-02

    DNA glycosylases specialized for the repair of alkylation damage must identify, with fine specificity, a diverse array of subtle modifications within DNA. The current mechanism involves damage sensing through interrogation of the DNA duplex, followed by more specific recognition of the target base inside the active site pocket. To better understand the physical basis for alkylpurine detection, we determined the crystal structure of Schizosaccharomyces pombe Mag1 (spMag1) in complex with DNA and performed a mutational analysis of spMag1 and the close homologue from Saccharomyces cerevisiae (scMag). Despite strong homology, spMag1 and scMag differ in substrate specificity and cellular alkylation sensitivity, although the enzymological basis for their functional differences is unknown. We show that Mag preference for 1,N{sup 6}-ethenoadenine ({var_epsilon}A) is influenced by a minor groove-interrogating residue more than the composition of the nucleobase-binding pocket. Exchanging this residue between Mag proteins swapped their {var_epsilon}A activities, providing evidence that residues outside the extrahelical base-binding pocket have a role in identification of a particular modification in addition to sensing damage.

  8. In Favour of Mature-Aged Graduates (MAGs)--Tapping the Potential for Real Educational Change

    ERIC Educational Resources Information Center

    Uusimaki, Liisa

    2011-01-01

    Mature-aged graduates (MAGs) are characterised by significant life experience, including career change and an altruistic desire to benefit their prospective students. They are particularly well suited to the middle school environment with its focus on transition and its often complex student needs. Despite this, MAGs are currently underserviced by…

  9. 21 CFR 864.3600 - Microscopes and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories §...

  10. 21 CFR 864.3600 - Microscopes and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories §...

  11. 21 CFR 864.3600 - Microscopes and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories §...

  12. 21 CFR 864.3600 - Microscopes and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Microscopes and accessories. 864.3600 Section 864.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories §...

  13. 21 CFR 884.2700 - Intrauterine pressure monitor and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intrauterine pressure monitor and accessories. 884... Monitoring Devices § 884.2700 Intrauterine pressure monitor and accessories. (a) Identification. An intrauterine pressure monitor is a device designed to detect and measure intrauterine and amniotic...

  14. 14 CFR 121.251 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Engine accessory section diaphragm. 121.251 Section 121.251 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm...

  15. 14 CFR 125.149 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate...

  16. 21 CFR 884.5350 - Contraceptive diaphragm and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive...

  17. 21 CFR 884.5350 - Contraceptive diaphragm and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive...

  18. 14 CFR 125.149 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate...

  19. 14 CFR 125.149 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate...

  20. 14 CFR 121.251 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Engine accessory section diaphragm. 121.251 Section 121.251 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm...

  1. 21 CFR 884.5350 - Contraceptive diaphragm and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive...

  2. 21 CFR 884.5350 - Contraceptive diaphragm and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive...

  3. 14 CFR 121.251 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Engine accessory section diaphragm. 121.251 Section 121.251 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm...

  4. 21 CFR 884.5350 - Contraceptive diaphragm and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Contraceptive diaphragm and accessories. 884.5350 Section 884.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Devices § 884.5350 Contraceptive diaphragm and accessories. (a) Identification. A contraceptive...

  5. 21 CFR 884.1690 - Hysteroscope and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hysteroscope and accessories. 884.1690 Section 884.1690 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Diagnostic Devices § 884.1690 Hysteroscope and accessories....

  6. 14 CFR 23.1437 - Accessories for multiengine airplanes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 23.1437 Accessories for multiengine airplanes. For multiengine airplanes... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Accessories for multiengine airplanes....

  7. 14 CFR 125.149 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate...

  8. 14 CFR 125.149 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Engine accessory section diaphragm. 125.149... Requirements § 125.149 Engine accessory section diaphragm. Unless equivalent protection can be shown by other means, a diaphragm that complies with § 125.145 must be provided on air-cooled engines to isolate...

  9. 14 CFR 23.1192 - Engine accessory compartment diaphragm.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Engine accessory compartment diaphragm. 23... Powerplant Powerplant Fire Protection § 23.1192 Engine accessory compartment diaphragm. For aircooled radial engines, the engine power section and all portions of the exhaust sytem must be isolated from the...

  10. 46 CFR 98.25-40 - Valves, fittings, and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Anhydrous Ammonia in Bulk § 98.25-40 Valves, fittings, and accessories. (a) All valves, flanges, fittings and accessory equipment shall be of a type suitable for use with anhydrous ammonia and shall be made... Engineering) of this chapter. Valves shall be fitted with noncorrosive material suitable for ammonia...

  11. 46 CFR 98.25-40 - Valves, fittings, and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Anhydrous Ammonia in Bulk § 98.25-40 Valves, fittings, and accessories. (a) All valves, flanges, fittings and accessory equipment shall be of a type suitable for use with anhydrous ammonia and shall be made... Engineering) of this chapter. Valves shall be fitted with noncorrosive material suitable for ammonia...

  12. 46 CFR 98.25-40 - Valves, fittings, and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Anhydrous Ammonia in Bulk § 98.25-40 Valves, fittings, and accessories. (a) All valves, flanges, fittings and accessory equipment shall be of a type suitable for use with anhydrous ammonia and shall be made... Engineering) of this chapter. Valves shall be fitted with noncorrosive material suitable for ammonia...

  13. 21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Monitoring Devices § 884.2640 Fetal phonocardiographic monitor and accessories. (a) Identification. A...

  14. 21 CFR 884.2960 - Obstetric ultrasonic transducer and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Obstetric ultrasonic transducer and accessories. 884.2960 Section 884.2960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Monitoring Devices § 884.2960 Obstetric ultrasonic transducer and accessories. (a) Identification....

  15. 21 CFR 884.2740 - Perinatal monitoring system and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Perinatal monitoring system and accessories. 884.2740 Section 884.2740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Monitoring Devices § 884.2740 Perinatal monitoring system and accessories. (a) Identification. A...

  16. 21 CFR 884.2700 - Intrauterine pressure monitor and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intrauterine pressure monitor and accessories. 884.2700 Section 884.2700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Monitoring Devices § 884.2700 Intrauterine pressure monitor and accessories. (a) Identification....

  17. Morphological characteristics of the cranial root of the accessory nerve.

    PubMed

    Liu, Hong-Fu; Won, Hyung-Sun; Chung, In-Hyuk; Kim, In-Beom; Han, Seung-Ho

    2014-11-01

    There has been the controversy surrounding the cranial root (CR) of the accessory nerve. This study was performed to clarify the morphological characteristics of the CR in the cranial cavity. Fifty sides of 25 adult cadaver heads were used. The accessory nerve was easily distinguished from the vagus nerve by the dura mater in the jugular foramen in 80% of 50 specimens. The trunk of the accessory nerve from the spinal cord penetrated the dura mater at various distances before entering the jugular foramen. In 20% of the specimens there was no dural boundary. In these cases, the uppermost cranial rootlet of the accessory nerve could be identified by removing the dura mater around the jugular foramen where it joined to the trunk of the accessory nerve at the superior vagal ganglion. The cranial rootlet was formed by union of two to four short filaments emerging from the medulla oblongata (66%) and emerged single, without filament (34%), and usually joined the trunk of the accessory nerve directly before the jugular foramen. The mean number of rootlets of the CR was 4.9 (range 2-9) above the cervicomedullary junction. The CR of the accessory nerve was composed of two to nine rootlets, which were formed by the union of two to four short filaments and joined the spinal root of the accessory nerve. The CR is morphologically distinct from the vagus nerve, confirming its existence.

  18. Simon Effect with and without Awareness of the Accessory Stimulus

    ERIC Educational Resources Information Center

    Treccani, Barbara; Umilta, Carlo; Tagliabue, Mariaelena

    2006-01-01

    The authors investigated whether a Simon effect could be observed in an accessory-stimulus Simon task when participants were unaware of the task-irrelevant accessory cue. In Experiment 1A a central visual target was accompanied by a suprathreshold visual lateral cue. A regular Simon effect (i.e., faster cue-response corresponding reaction times…

  19. 14 CFR 23.1437 - Accessories for multiengine airplanes.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Accessories for multiengine airplanes. 23... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 23.1437 Accessories for multiengine airplanes. For multiengine...

  20. 14 CFR 23.1437 - Accessories for multiengine airplanes.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Accessories for multiengine airplanes. 23... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 23.1437 Accessories for multiengine airplanes. For multiengine...

  1. 14 CFR 23.1437 - Accessories for multiengine airplanes.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Accessories for multiengine airplanes. 23... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Equipment Miscellaneous Equipment § 23.1437 Accessories for multiengine airplanes. For multiengine...

  2. 21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic monitor is a device designed to transmit and receive ultrasonic energy into and from the pregnant...

  3. MAG, myelin and overcoming growth inhibition in the CNS

    PubMed Central

    McKerracher, Lisa; Rosen, Kenneth M.

    2015-01-01

    While neurons in the central nervous system (CNS) have the capacity to regenerate their axons after injury, they fail to do so, in part because regeneration is limited by growth inhibitory proteins present in CNS myelin. Myelin-associated glycoprotein (MAG) was the first myelin-derived growth inhibitory protein identified, and its inhibitory activity was initially elucidated in 1994 independently by the Filbin lab and the McKerracher lab using cell-based and biochemical techniques, respectively. Since that time we have gained a wealth of knowledge concerning the numerous growth inhibitory proteins that are present in myelin, and we also have dissected many of the neuronal signaling pathways that act as stop signs for axon regeneration. Here we give an overview of the early research efforts that led to the identification of myelin-derived growth inhibitory proteins, and the importance of this family of proteins for understanding neurotrauma and CNS diseases. We further provide an update on how this knowledge has been translated towards current clinical studies in regenerative medicine. PMID:26441514

  4. Low-Altitude Magnetic Topology with MAVEN SWEA and MAG

    NASA Astrophysics Data System (ADS)

    Mitchell, David; Xu, Shaosui; Mazelle, Christian; Luhmann, Janet; McFadden, James; Connerney, John; Liemohn, Michael; Dong, Chuanfei; Bougher, Stephen; Fillingim, Matthew

    2016-04-01

    The Solar Wind Electron Analyzer (SWEA) and Magnetometer (MAG) onboard the MAVEN spacecraft measure electron pitch angle and energy distributions at 2-second resolution (~8 km along the orbit track) to determine the topology of magnetic fields from both external and crustal sources. Electrons from different regions of the Mars environment can be distinguished by their energy distributions. Thus, pitch angle resolved energy spectra can be used to determine the plasma source regions sampled by a field line at large distances from the spacecraft. From 12/1/2014 to 2/15/2015, when periapsis was at high northern latitudes, SWEA observed ionospheric photoelectrons at low altitudes (140-200 km) and high solar zenith angles (120-145 degrees) on ~35% of the orbits. Since this electron population is unambiguously produced in the dayside ionosphere, these observations demonstrate that the deep Martian nightside is at times magnetically connected to the sunlit hemisphere. The BATS-R-US Mars multi-fluid MHD model suggests the presence of closed crustal magnetic field lines over the northern hemisphere that straddle the terminator and extend to high SZA. Simulations with the SuperThermal Electron Transport (STET) model show that photoelectron transport along such field lines can take place without significant attenuation. Precipitation of photoelectrons onto the night-side atmosphere should cause ionization and possibly auroral emissions in localized regions. On one orbit, the O2+ energy flux measured by STATIC correlates well with precipitating photoelectron fluxes.

  5. Window decompression in laser-heated MagLIF targets

    NASA Astrophysics Data System (ADS)

    Woodbury, Daniel; Peterson, Kyle; Sefkow, Adam

    2015-11-01

    The Magnetized Liner Inertial Fusion (MagLIF) concept requires pre-magnetized fuel to be pre-heated with a laser before undergoing compression by a thick solid liner. Recent experiments and simulations suggest that yield has been limited to date by poor laser preheat and laser-induced mix in the fuel region. In order to assess laser energy transmission through the pressure-holding window, as well as resultant mix, we modeled window disassembly under different conditions using 1D and 2D simulations in both Helios and HYDRA. We present results tracking energy absorption, time needed for decompression, risk of laser-plasma interaction (LPI) that may scatter laser light, and potential for mix from various window thicknesses, laser spot sizes and gas fill densities. These results indicate that using thinner windows (0.5-1 μm windows) and relatively large laser spot radii (600 μm and above) can avoid deleterious effects and improve coupling with the fuel. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the National Nuclear Security Administration under DE-AC04- 94AL85000.

  6. MagLifter Site Investigation and Implementation Strategies

    NASA Technical Reports Server (NTRS)

    Burke, Pamela; Slaughter, Maynard; Beer, C. Neil

    1995-01-01

    MagLifter, as defined here, is an advanced, earth-bound catapult system to provide the initial lift for earth orbiting vehicles to reduce or eliminate the need for multistage propulsion, thus reducing the cost of orbital space flight. It is presumed that magnetic levitation will catapult the vehicle to a desired initial velocity sufficient for reaching orbit with the vehicles own engines. Of necessity, the system must be located on and around a mountain with sufficient relief to allow the catapult to accelerate the launch vehicle to a sufficient speed in the desired direction to allow it to reach orbit. Such a mountain site must meet criteria consistent with current and future space launch needs and conditions. It is the purpose of this report to set forth preliminary criteria for choosing a suitable maglifter site. The report is divided into four major sections: (1) Assumed Launch System and Flight Vehicle Characteristics; (2) Task 1.A - Initial Site Selection Criteria; (3) Conclusions; and (4) Appendix - Phases of the Site Selection Process.

  7. Fractal Analysis of Metal Transfer in Mig/mag Welding

    NASA Astrophysics Data System (ADS)

    Vieira, A. P.; Vasconcelos, H. H. M.; Gonçalves, L. L.; de Miranda, H. C.

    2009-03-01

    We apply techniques of fractal analysis in order to classify metal-transfer mode in MIG/MAG (metal inert/active gas) welding, which are among the most commonly employed arc-fusion processes for industrial applications. We work with voltage and current time series obtained during welding, and evaluate statistical fluctuations present in those series by Hurst, detrended-fluctuation, and detrended-cross-correlation analyses, for each of three different metal-transfer modes: short-circuiting, globular, and spray. For a given total timespan of each series, curves of fluctuation as a funtion of the time-window size are processed by using pattern-classification techniques, such as principal-component analysis and Karhunen-Loève expansions. We obtain near 100% success rate for the classification, with timespans as small as 100 miliseconds, with a processing time of the same order. This suggests that our set of tools can be incorporated into an industrial welding apparatus in order to guarantee automatic correction of a process requiring a single metal-transfer mode.

  8. Solar Probe Plus MAG Sensor Thermal Design for Low Heater Power and Extreme Thermal Environment

    NASA Technical Reports Server (NTRS)

    Choi, Michael K.

    2015-01-01

    The heater power available for the Solar Probe Plus FIELDS MAG sensor is less than half of the heritage value for other missions. Nominally the MAG sensors are in the spacecraft's umbra. In the worst hot case, approximately 200 spacecraft communication downlinks, up to 10 hours each, are required at 0.7 AU. These downlinks require the spacecraft to slew 45 deg. about the Y-axis, exposing the MAG sensors and boom to sunlight. This paper presents the thermal design to meet the MAG sensor thermal requirements in the extreme thermal environment and with low heater power. A thermal balance test on the MAG sensor engineering model has verified the thermal design and correlated the thermal model for flight temperature predictions.

  9. Gland With Cantilever Seal

    NASA Technical Reports Server (NTRS)

    Melton, Patrick B.

    1989-01-01

    Single-piece gland forms tight seal on probe or tube containing liquid or gas at high pressure. Gland and probe align as assembled by simple torquing procedure. Disconnected easily and reused at same site. Made from any of wide variety of materials so compatible with application. Cantilever ring at top of gland bites into wall of tube or probe, sealing it. Wall of tube or probe must be thick enough to accommodate deformation without rupturing. Maximum deformation designed in coordination with seating and deformation of boss or conical seal.

  10. Glomerular filtration and tubular secretion of MAG-3 in the rat kidney

    SciTech Connect

    Mueller-Suur, R.M.; Mueller-Suur, C. )

    1989-12-01

    Technetium-99m mercaptoacetyltriglycine (MAG-3) has recently been introduced as a new radiopharmaceutical for dynamic renal scintigraphy. To elucidate the mechanism of renal excretion, micropuncture experiments were performed in rat kidneys for direct measurements of glomerular filtration and tubular secretory capacity. Fluid of Bowman space was collected from superficial glomeruli and analyzed for its contents of (99mTc)MAG-3, (125I)hippurate and (3H)inulin during constant infusion of these compounds. The ratio of activity of ultrafiltrate to that of arterial plasma was 0.23 for MAG-3, 0.68 for hippurate and 1.04 for inulin which demonstrates that the filtrated amount of MAG-3 is only 23% of that of inulin, presumably because of higher plasma protein binding which was also measured in vitro and found to be 80 +/- 1.5% for MAG-3 and 32 +/- 2% for (125I)hippurate. Proximal and distal tubules were also micropunctured and their tubular fluid as well as the final urine analyzed for the activity of hippurate and MAG-3. The tubular fluid to plasma ratio values along the nephron and in the final urine were all lower for MAG-3 than for hippurate, indicating a lower secretory capacity. From measurements of whole renal clearance, GFR and plasma protein binding the filtered amount of MAG-3 was 0.26 and of hippurate 0.87 ml/min.g kidney weight (p less than 0.001) and the secreted amount 2.01 and 2.38 ml/min.g kidney weight (p less than 0.05), respectively. We conclude that MAG-3 is predominantly excreted by tubular secretion and that the lower renal clearance of MAG-3 as compared with that of hippurate is a result both of a substantially decreased glomerular filtration and of a lower tubular secretion.

  11. MAG4 Versus Alternative Techniques for Forecasting Active-Region Flare Productivity

    NASA Technical Reports Server (NTRS)

    Falconer, David A.; Moore, Ronald L.; Barghouty, Abdulnasser F.; Khazanov, Igor

    2014-01-01

    MAG4 is a technique of forecasting an active region's rate of production of major flares in the coming few days from a free-magnetic-energy proxy. We present a statistical method of measuring the difference in performance between MAG4 and comparable alternative techniques that forecast an active region's major-flare productivity from alternative observed aspects of the active region. We demonstrate the method by measuring the difference in performance between the "Present MAG4" technique and each of three alternative techniques, called "McIntosh Active-Region Class," "Total Magnetic Flux," and "Next MAG4." We do this by using (1) the MAG4 database of magnetograms and major-flare histories of sunspot active regions, (2) the NOAA table of the major-flare productivity of each of 60 McIntosh active-region classes of sunspot active regions, and (3) five technique-performance metrics (Heidke Skill Score, True Skill Score, Percent Correct, Probability of Detection, and False Alarm Rate) evaluated from 2000 random two-by-two contingency tables obtained from the databases. We find that (1) Present MAG4 far outperforms both McIntosh Active-Region Class and Total Magnetic Flux, (2) Next MAG4 significantly outperforms Present MAG4, (3) the performance of Next MAG4 is insensitive to the forward and backward temporal windows used, in the range of one to a few days, and (4) forecasting from the free-energy proxy in combination with either any broad category of McIntosh active-region classes or any Mount Wilson active-region class gives no significant performance improvement over forecasting from the free-energy proxy alone (Present MAG4).

  12. MAG-EPA reduces severity of DSS-induced colitis in rats.

    PubMed

    Morin, Caroline; Blier, Pierre U; Fortin, Samuel

    2016-05-15

    Ulcerative colitis (UC) is a chronic disease characterized by diffuse inflammation of the intestinal mucosa of the large bowel. Omega-3 (ω3) fatty acid supplementation has been associated with a decreased production of inflammatory cytokines involved in UC pathogenesis. The aim of this study was to determine the preventive and therapeutic potential of eicosapentaenoic acid monoglyceride (MAG-EPA) in an in vivo rats model of UC induced by dextran sulfate sodium (DSS). DSS rats were untreated or treated per os with MAG-EPA. Morphological, histological, and biochemical analyses were performed following MAG-EPA administrations. Morphological and histological analyses revealed that MAG-EPA pretreatment (12 days pre-DSS) and treatment (6 days post-DSS) exhibited strong activity in reducing severity of disease in DSS rats. Following MAG-EPA administrations, tissue levels of the proinflammatory cytokines TNF-α, IL-1β, and IL-6 were markedly lower compared with rats treated only with DSS. MAG-EPA per os administration decrease neutrophil infiltration in colon tissues, as depicted by myelohyperoxidase activity. Results also revealed a reduced activation of NF-κB pathways correlated with a decreased expression of COX-2 in colon homogenates derived from MAG-EPA-pretreated and treated rats. Tension measurements performed on colon tissues revealed that contractile responses to methacholine and relaxing effect induced by sodium nitroprusside were largely increased following MAG-EPA treatment. The combined treatment of MAG-EPA and vitamin E displayed an antagonistic effect on anti-inflammatory properties of MAG-EPA in DSS rats.

  13. [The pathology of salivary glands. Tumors of the salivary glands].

    PubMed

    Mahy, P; Reychler, H

    2006-01-01

    The management of benign and malignant neoplasms of the salivary glands requires precise knowledge of tumor histogenesis and classification as well as surgical skills. Pleomorphic adenoma and Whartin's tumor are the most frequent tumors in parotid glands while the probability for malignant tumors is higher in other glands, especially in sublingual and minor salivary glands. Those malignant salivary glands tumors are rare and necessitate multidisciplinar staging and management in close collaboration with the pathologist and the radiation oncologist.

  14. Contribution of the secretory material of caecilian (amphibia: Gymnophiona) male Mullerian gland to motility of sperm: a study in Uraeotyphlus narayani.

    PubMed

    George, Jancy M; Smita, Mathew; Kadalmani, Balamuthu; Girija, Ramankutty; Oommen, Oommen V; Akbarsha, Mohammad A

    2005-02-01

    Caecilians are a unique group of limbless burrowing amphibians with discontinuous distribution. Several caecilian species are viviparous, and all practice internal fertilization. In amniotic vertebrates the sperm undergo post-testicular physiological maturation when they are initiated into motility under the influence of an epididymal secretion. Further, during ejaculation mammalian sperm are suspended in a fluid secreted by the male accessory sex glands, viz., prostate gland and seminal vesicles. Caecilians lack comparable glands, but still practice internal fertilization. Uniquely, male caecilians retain the Mullerian ducts in the adults as a pair of functional glands. It has long been hypothesized, based on indirect evidence, that the Mullerian gland would be a male accessory sex gland, secreting a fluid in which sperm are suspended during ejaculation and which would also provide nutritional support to the ejaculated sperm. In the present study, the secretory material of the Mullerian gland of Uraeotyphlus narayani was mixed with sperm obtained from the testis, and the changes in motility were recorded. Uraeotyphlus narayani sperm possess a perforatorium of the acrosome proceeding deep into the endonuclear canal of the nucleus. The midpiece is characterized by closely applied centrioles, the anterior ends of the axoneme and axial fiber, and a mitochondrial sheath. The long tail has an undulating membrane on one side, supported by the axoneme and an axial fiber. The live sperm possess a mitochondrial vesicle, also known as the cytoplasmic droplet, anywhere along the head and the midpiece, as in anuran sperm, which is shed from sperm that have ceased motility. Uraeotyphlus narayani sperm are motile the moment they are released directly from the testis, indicating that the sperm do not require post-testicular physiological maturation. On being mixed with the secretory material of the Mullerian gland, the spermatozoa are enhanced in speed as well as duration of

  15. Contribution of the secretory material of caecilian (amphibia: Gymnophiona) male Mullerian gland to motility of sperm: a study in Uraeotyphlus narayani.

    PubMed

    George, Jancy M; Smita, Mathew; Kadalmani, Balamuthu; Girija, Ramankutty; Oommen, Oommen V; Akbarsha, Mohammad A

    2005-02-01

    Caecilians are a unique group of limbless burrowing amphibians with discontinuous distribution. Several caecilian species are viviparous, and all practice internal fertilization. In amniotic vertebrates the sperm undergo post-testicular physiological maturation when they are initiated into motility under the influence of an epididymal secretion. Further, during ejaculation mammalian sperm are suspended in a fluid secreted by the male accessory sex glands, viz., prostate gland and seminal vesicles. Caecilians lack comparable glands, but still practice internal fertilization. Uniquely, male caecilians retain the Mullerian ducts in the adults as a pair of functional glands. It has long been hypothesized, based on indirect evidence, that the Mullerian gland would be a male accessory sex gland, secreting a fluid in which sperm are suspended during ejaculation and which would also provide nutritional support to the ejaculated sperm. In the present study, the secretory material of the Mullerian gland of Uraeotyphlus narayani was mixed with sperm obtained from the testis, and the changes in motility were recorded. Uraeotyphlus narayani sperm possess a perforatorium of the acrosome proceeding deep into the endonuclear canal of the nucleus. The midpiece is characterized by closely applied centrioles, the anterior ends of the axoneme and axial fiber, and a mitochondrial sheath. The long tail has an undulating membrane on one side, supported by the axoneme and an axial fiber. The live sperm possess a mitochondrial vesicle, also known as the cytoplasmic droplet, anywhere along the head and the midpiece, as in anuran sperm, which is shed from sperm that have ceased motility. Uraeotyphlus narayani sperm are motile the moment they are released directly from the testis, indicating that the sperm do not require post-testicular physiological maturation. On being mixed with the secretory material of the Mullerian gland, the spermatozoa are enhanced in speed as well as duration of

  16. [Meibomian gland morphology study progression].

    PubMed

    Wang, Yuqian; Dong, Nuo; Wu, Huping

    2014-04-01

    The meibomian gland (MG) in the eyelids, which is the largest sebaceous gland throughout the body, synthesize and secrete lipids to form the superficial tear film layer. It plays a key role in maintaining the ocular surface health. Abnormalities in meibomian gland morphology lead to meibomian gland dysfunction, which is the main cause of evaporative dry eye. Study on meibomian gland morphology will contribute significantly to the diagnosis and treatment of meibomian gland dysfunction. This review is just focusing on the current studies about techniques to visualize the morphology of the MG and changes of meibomian gland morphology related to diseases.

  17. [Meibomian gland morphology study progression].

    PubMed

    Wang, Yuqian; Dong, Nuo; Wu, Huping

    2014-04-01

    The meibomian gland (MG) in the eyelids, which is the largest sebaceous gland throughout the body, synthesize and secrete lipids to form the superficial tear film layer. It plays a key role in maintaining the ocular surface health. Abnormalities in meibomian gland morphology lead to meibomian gland dysfunction, which is the main cause of evaporative dry eye. Study on meibomian gland morphology will contribute significantly to the diagnosis and treatment of meibomian gland dysfunction. This review is just focusing on the current studies about techniques to visualize the morphology of the MG and changes of meibomian gland morphology related to diseases. PMID:24931156

  18. Hunting for eruption ages in accessory minerals

    NASA Astrophysics Data System (ADS)

    Vazquez, J. A.

    2012-12-01

    A primary goal in geochronology is to provide precise and accurate ages for tephras that serve as chronostratigraphic markers for constraining the timing and rates of volcanism, sedimentation, climate change, and catastrophic events in Earth history. Zircon remains the most versatile accessory mineral for dating silicic tephras due to its common preservation in distal pyroclastic deposits, as well as the robustness of its U-Pb and U-series systems even after host materials have been hydrothermally altered or weathered. Countless studies document that zircon may be complexly zoned in age due to inheritance, contamination, recycling of antecrysts, protracted crystallization in long-lived magma reservoirs, or any combination of these. Other accessory minerals such as allanite or chevkinite can retain similar records of protracted crystallization. If the goal is to date the durations of magmatic crystallization, differentiation, and/or magma residence, then these protracted chronologies within and between accessory minerals are a blessing. However, if the goal is to date the timing of eruption with high precision, i.e., absolute ages with millennial-scale uncertainties, then this age zoning is a curse. Observations from ion microprobe 238U-230Th dating of Pleistocene zircon and allanite provide insight into the record of near-eruption crystallization in accessory minerals and serve as a guide for high-precision whole-crystal dating. Although imprecise relative to conventional techniques, ion probe analysis allows high-spatial resolution 238U-230Th dating that can document multi-millennial age distributions at the crystal scale. Analysis of unpolished rims and continuous depth profiling of zircon from small and large volume eruptions (e.g., Coso, Mono Craters, Yellowstone) reveals that the final several micrometers of crystallization often yield ages that are indistinguishable from associated eruption ages from the 40Ar/39Ar or (U-Th)/He methods. Using this approach, we

  19. Fluid assisted installation of electrical cable accessories

    DOEpatents

    Mayer, Robert W.; Silva, Frank A.

    1977-01-01

    An electrical cable accessory includes a generally tubular member of elastomeric material which is to be installed by placement over a cylindrical surface to grip the cylindrical surface, when in appropriate assembled relation therewith, with a predetermined gripping force established by dilation of the tubular member, the installation being facilitated by introducing fluid under pressure, through means provided in the tubular member, between the tubular member and the cylindrical surface, and simultaneously impeding the escape of the fluid under pressure from between the tubular member and the cylindrical surface by means adjacent one of the ends of the tubular member to cause dilation of the tubular member and establish a fluid layer between the tubular member and the cylindrical surface, thereby reducing the gripping force during installation.

  20. Endocrine Glands & Their Hormones

    MedlinePlus

    ... Home » Cancer Registration & Surveillance Modules » Anatomy & Physiology » Endocrine System » Endocrine Glands & Their Hormones Cancer Registration & Surveillance Modules Anatomy & Physiology Intro to the Human Body Body Functions & Life Process Anatomical Terminology Review Quiz ...

  1. Laparoscopic Adrenal Gland Removal

    MedlinePlus

    ... adrenal tumors that appear malignant. What are the Advantages of Laparoscopic Adrenal Gland Removal? In the past, ... of procedure and the patients overall condition. Common advantages are: Less postoperative pain Shorter hospital stay Quicker ...

  2. Enlarged prostate gland

    MedlinePlus

    ... enlarges in size in a process called benign hypertrophy, which means that the gland got larger without ... in several of the symptoms of benign prostatic hypertrophy, or BPH. Symptoms may include a slowed or ...

  3. Adrenal glands (image)

    MedlinePlus

    Triangular-shaped glands located on top of the kidneys. They produce hormones such as estrogen, progesterone, steroids, cortisol, and cortisone, and chemicals such as adrenalin (epinephrine), norepinephrine, and dopamine.

  4. MAG4 versus alternative techniques for forecasting active region flare productivity

    PubMed Central

    Falconer, David A; Moore, Ronald L; Barghouty, Abdulnasser F; Khazanov, Igor

    2014-01-01

    MAG4 is a technique of forecasting an active region's rate of production of major flares in the coming few days from a free magnetic energy proxy. We present a statistical method of measuring the difference in performance between MAG4 and comparable alternative techniques that forecast an active region's major-flare productivity from alternative observed aspects of the active region. We demonstrate the method by measuring the difference in performance between the “Present MAG4” technique and each of three alternative techniques, called “McIntosh Active-Region Class,” “Total Magnetic Flux,” and “Next MAG4.” We do this by using (1) the MAG4 database of magnetograms and major flare histories of sunspot active regions, (2) the NOAA table of the major-flare productivity of each of 60 McIntosh active-region classes of sunspot active regions, and (3) five technique performance metrics (Heidke Skill Score, True Skill Score, Percent Correct, Probability of Detection, and False Alarm Rate) evaluated from 2000 random two-by-two contingency tables obtained from the databases. We find that (1) Present MAG4 far outperforms both McIntosh Active-Region Class and Total Magnetic Flux, (2) Next MAG4 significantly outperforms Present MAG4, (3) the performance of Next MAG4 is insensitive to the forward and backward temporal windows used, in the range of one to a few days, and (4) forecasting from the free-energy proxy in combination with either any broad category of McIntosh active-region classes or any Mount Wilson active-region class gives no significant performance improvement over forecasting from the free-energy proxy alone (Present MAG4). Key Points Quantitative comparison of performance of pairs of forecasting techniques Next MAG4 forecasts major flares more accurately than Present MAG4 Present MAG4 forecast outperforms McIntosh AR Class and total magnetic flux PMID:26213517

  5. Benign Pediatric Salivary Gland Lesions.

    PubMed

    Carlson, Eric R; Ord, Robert A

    2016-02-01

    Salivary gland lesions are rare in pediatric patients. In addition, the types of salivary gland tumors are different in their distribution in specific sites in the major and minor salivary glands in children compared with adults. This article reviews benign neoplastic and nonneoplastic salivary gland disorders in pediatric patients to help clinicians to develop an orderly differential diagnosis that will lead to expedient treatment of pediatric patients with salivary gland lesions.

  6. Radionuclide salivary gland imaging

    SciTech Connect

    Mishkin, F.S.

    1981-10-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific.

  7. Mammary Gland Development

    PubMed Central

    Macias, Hector

    2012-01-01

    The mammary gland develops through several distinct stages. The first transpires in the embryo as the ectoderm forms a mammary line that resolves into placodes. Regulated by epithelial/mesenchymal interactions, the placodes descend into the underlying mesenchyme and produce the rudimentary ductal structure of the gland present at birth. Subsequent stages of development – pubertal growth, pregnancy, lactation and involution – occur postnatally under the regulation of hormones. Puberty initiates branching morphogenesis, which requires growth hormone and estrogen, as well as IGF1, to create a ductal tree that fills the fat pad. Upon pregnancy the combined actions of progesterone and prolactin generate alveoli, which secrete milk during lactation. Lack of demand for milk at weaning initiates the process of involution whereby the gland is remodeled back to its pre-pregnancy state. These processes require numerous signaling pathways that have distinct regulatory functions at different stages of gland development. Signaling pathways also regulate a specialized subpopulation of mammary stem cells that fuel the dramatic changes in the gland occurring with each pregnancy. Our knowledge of mammary gland development and mammary stem cell biology has significantly contributed to our understanding of breast cancer and has advanced the discovery of therapies to treat this disease. PMID:22844349

  8. Human Papilloma Virus Infection in Patients with Male Accessory Gland Infection: Usefulness of the Ultrasound Evaluation

    PubMed Central

    Condorelli, Rosita A.; Vicari, Enzo; Mongioi, Laura M.

    2016-01-01

    This study evaluated the ultrasound (US) features of 20 patients with MAGI and concomitant papilloma virus (HPV) infection compared to 20 patients with microbial (presence of Chlamydia trachomatis alone) MAGI and 20 patients with amicrobial (inflammatory) MAGI. Patients with HPV infection showed significantly (p < 0.05) higher total prostate, seminal vesicles, and epididymal US signs (18.0 ± 2.0) compared to the other 2 groups (12.0 ± 4.0 versus 10.0 ± 3.0, resp.). In addition, patients with MAGI and HPV had a higher prevalence of complicated forms of MAGI [prostatovesiculitis (PV) and prostate-vesiculo-epididymitis (PVE)] and a higher frequency of the fibrosclerotic variant compared to the other groups (70.0 ± 10.0% versus 48.0 ± 5.0% versus 15.0 ± 10.0%). Moreover, HPV infected patients had a higher number of US criteria suggestive for MAGI in the periurethral region of the prostate compared to the other groups. In particular, the patients showed a higher ratio between periurethral and lobar US criteria distribution (5.0 versus 0.5). Finally, the seminal fluid concentration of CD45pos leukocytes (2.0 ± 0.2 versus 1.3 ± 0.3 versus 1.0 ± 0.3 mil/mL) was significantly higher and sperm progressive motility was significantly lower in these patients compared to other groups. PMID:27242899

  9. Meibomian gland dysfunction. III. Meibomian gland lipids.

    PubMed

    Nicolaides, N; Santos, E C; Smith, R E; Jester, J V

    1989-05-01

    The lipid components of meibomian gland excreta were evaluated in rabbits after they received 2% topical epinephrine dropped into their eyes daily for a period of 6 months to a year to induce meibomian gland dysfunction (MGD). Changes were compared to excreta obtained from seven age-matched, untreated control rabbits. Comparison of the lipids from MGD lids with lipids obtained from control rabbits revealed, for clinically evident MGD, a marked increase in the lipids that are uniquely characteristic of epidermal tissue. These epidermal lipids are free sterols (large amounts) and a group of seven types of ceramides. The data are consistent with the hypothesis that the initiating factor of rabbit MGD is hyperkeratinization of the ductal epithelia. For clinically apparent MGD some hydrolysis of the sterol esters of the meibomian gland lipids also seems to have occurred. This was evidenced by the formation of an 8-fold increase in a cluster of anteiso fatty acids with chain lengths longer than C20 in the free fatty acid fraction. This group of free fatty acids was the same as the acids esterified to the sterol esters. We could detect no change in the lipid excreta obtained from rabbits that developed only subclinical MGD, consisting of orifice plugging and dilation of the duct.

  10. Accessory bands of the hamstring tendons: A clinical anatomical study.

    PubMed

    Yasin, M N; Charalambous, C P; Mills, S P; Phaltankar, P M

    2010-10-01

    Gracilis and semitendinosus tendons are commonly used as grafts in ligamentous reconstruction. Awareness of accessory bands of these tendons is essential in preventing inadvertent diversion of the tendon harvester into the main tendon resulting in premature tendon amputation and inadequate tendon graft. The aim of this study was to describe the characteristics of these accessory bands. Twenty five patients undergoing arthroscopic anterior cruciate ligament reconstruction using hamstring tendons were included. The number of accessory bands and distance of the most proximal band from the distal periosteal insertion point on the tibial crest was recorded for both gracilis and semitendinosus. In most cases gracilis had two accessory bands; the average distance of the most proximal band from the tibial crest insertion being 5.1 cm. Semitendinosus had three bands in most cases, the average distance of the most proximal band from the tibial crest insertion being 8.1 cm. Five (20%) semitendinosus but no gracilis tendons had an accessory band originating greater than 10 cm from the tibial crest insertion. Semitendinosus had more accessory bands compared to gracilis. A significant proportion (20%) of semitendinosus and none of the gracilis tendons had bands originating greater than 10 cm proximal to the tibial crest insertion. This knowledge about the accessory bands of the hamstrings can guide toward safe harvesting of these tendons.

  11. Mag-muBots: Magnetic micro-robots capable of mobility, manipulation, and modularity

    NASA Astrophysics Data System (ADS)

    Pawashe, Chytra Shashikant

    Micro-robots are mobile devices that operate in micro-scale environments, and have future applications, such as being used to manipulate or construct micro-devices, and being used as diagnostic and analysis tools in biological systems. Being sub-millimeter in size, micro-robots require very different approaches to fabricating, powering, and controlling them. As opposed to conventional large-scale robots, it is infeasible to integrate conventional-style motors, actuators, and power sources into micro-scale devices. In this work, the Magnetic Micro-Robot (Mag-muBot) is presented, which is a versatile permanent magnet-based mobile robot under 1 mm in all dimensions. External magnetic fields are employed to successfully deliver power and control to the Mag-muBot, which is mobile and can operate in both gases and liquids, and on unstructured surfaces. Its motion is achieved by oscillating magnetic fields, which induces a stick-slip walking behavior; these dynamics are modeled into a simulation that compares favorably to experiments. The mechanisms for the manipulation of micro-objects are also explored, where the Mag-muBot can directly push micro-objects by contact-manipulation, or generate fluid boundary layers to manipulate micro-objects without direct contact. Examples of micro-object manipulation are also provided, where objects from 50 mum to 900 mum are shown to be manipulated. Additionally, control topics are explored such as addressing multiple Mag-muBots on a surface, which is accomplished by utilizing electrostatic forces generated by a specialized surface that selectively immobilizes individual Mag-muBots, allowing for decoupled serial locomotion of multiple Mag-muBots. Furthermore, autonomous control algorithms are developed such that the Mag-muBot can autonomously be positioned in the workspace, plan around obstacles, and efficiently manipulate micro-objects in the environment. Finally, a micro-scale reconfigurable modular robotic system is developed, based

  12. Sonography of the accessory head of the biceps brachii.

    PubMed

    Lutterbach-Penna, Ricardo Augusto; Brigido, Monica Kalume; Robertson, Brian; Kim, Sung Moon; Jacobson, Jon A; Fessell, David P

    2014-10-01

    Anatomic variations in the anterior aspect of the shoulder, such as an accessory head of the biceps brachii muscle, are not uncommon. The magnetic resonance imaging and arthroscopic appearance of the accessory head of the biceps brachii has been recently described. This series demonstrates the sonographic appearance of the accessory head of the biceps brachii in the bicipital groove. It is an asymptomatic, flat, echogenic structure with average measurements of 7.7 × 1.2 mm in cross section. Knowledge of this anatomic variant can avoid the misdiagnosis of a longitudinal split tear and improve the accuracy of sonography.

  13. Accessory spleen compromising response to splenectomy for idiopathic thrombocytopenic purpura

    SciTech Connect

    Ambriz, P.; Munoz, R.; Quintanar, E.; Sigler, L.; Aviles, A.; Pizzuto, J.

    1985-06-01

    Accessory spleens were sought in 28 patients who had undergone splenectomy for chronic idiopathic thrombocytopenic purpura (ITP), using a variety of techniques. Abdominal scintigraphy with autologous erythrocytes labeled with Tc-99m and opsonized with anit-D IgG (radioimmune method) proved to be most useful, clearly demonstrating one or more accessory spleens in 12 cases (43%). Computed tomography (CT) was also helpful. Four out of five patients demonstrated an increased platelet count following surgery, the effectiveness of which was illustrated by the radioimmune scan. Patients who have had splenectomy for chronic ITP should be scanned using radioimmune techniques and CT to determine whether an accessory spleen is present.

  14. The evolution of sweat glands

    NASA Astrophysics Data System (ADS)

    Folk, G. Edgar; Semken, A.

    1991-09-01

    Mammals have two kinds of sweat glands, apocrine and eccrine, which provide for thermal cooling. In this paper we describe the distribution and characteristics of these glands in selected mammals, especially primates, and reject the suggested development of the eccrine gland from the apocrine gland during the Tertiary geological period. The evidence strongly suggests that the two glands, depending on the presence or absence of fur, have equal and similar functions among mammals; apocrine glands are not primitive. However, there is a unique and remarkable thermal eccrine system in humans; we suggest that this system evolved in concert with bipedalism and a smooth hairless skin.

  15. Sebaceous lymphadenoma of submandibular gland.

    PubMed

    Pattnaik, Niharika; Parmar, Deepankar; Rao, B Rama Mohan; Rao, Epari Sanjeeva

    2013-01-01

    Sebaceous lymphadenoma is a rare primary tumour of the salivary gland, benign in nature arising from differentiated Sebaceous glands and cells in the salivary gland. Most of the tumours are seen in the parotid gland and very rarely in the submandibular gland. Herein a case of sebaceous lymphadenoma is reported in a 45 years old female with a swelling in the submandibular region. Histopathological study after surgical excision showed islands of sebaceous epithelial cells with dense collections of lymphoid cells in stroma and a diagnosis of sebaceous lymphadenoma of submandibular gland was made.

  16. Lymphomas of salivary glands.

    PubMed

    Gleeson, M J; Bennett, M H; Cawson, R A

    1986-08-01

    Primary lymphomas arising in salivary glands are very uncommon. The histologic classification of 40 cases of lymphomas in salivary gland tissue submitted to the British Salivary Gland Tumour Panel is reported, and, for 30 of the patients for whom adequate information was available, the clinical presentation, management, and outcome have been analyzed. Lymphomas in salivary glands represented 1.7% of all reported salivary neoplasms. The majority developed in the parotid glands of patients aged between 50 and 70 years. Only four cases gave a premorbid history compatible with sicca syndrome. In this series, non-Hodgkin's lymphomas predominated; 23 were Grade I, and 13 were Grade II. Treatment regimens were not uniform, but are outlined. Survival ranged from 5 to 111 months. Median survival for the group was 49 months. Prognosis was not influenced by the clinical stage of disease at presentation. Four cases of lymphoma arising in benign lymphoepithelial lesions are included. None had clinical symptoms of sicca complex. Prognosis for this group was found to be as favorable as the others.

  17. 26 CFR 48.4061(b)-3 - Rebuilt, reconditioned, or repaired parts or accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... operations rather than the manufacturing or production of rebuilt parts or accessories. The sale of a... accessories. 48.4061(b)-3 Section 48.4061(b)-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE..., reconditioned, or repaired parts or accessories. (a) Rebuilt parts or accessories. Rebuilding of...

  18. 26 CFR 48.4061(b)-3 - Rebuilt, reconditioned, or repaired parts or accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... operations rather than the manufacturing or production of rebuilt parts or accessories. The sale of a... accessories. 48.4061(b)-3 Section 48.4061(b)-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE..., reconditioned, or repaired parts or accessories. (a) Rebuilt parts or accessories. Rebuilding of...

  19. 26 CFR 48.4061(b)-3 - Rebuilt, reconditioned, or repaired parts or accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... operations rather than the manufacturing or production of rebuilt parts or accessories. The sale of a... accessories. 48.4061(b)-3 Section 48.4061(b)-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE..., reconditioned, or repaired parts or accessories. (a) Rebuilt parts or accessories. Rebuilding of...

  20. 26 CFR 48.4061(b)-3 - Rebuilt, reconditioned, or repaired parts or accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... operations rather than the manufacturing or production of rebuilt parts or accessories. The sale of a... accessories. 48.4061(b)-3 Section 48.4061(b)-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE..., reconditioned, or repaired parts or accessories. (a) Rebuilt parts or accessories. Rebuilding of...

  1. A direct method for regiospecific analysis of TAG using alpha-MAG.

    PubMed

    Turon, F; Bachain, P; Caro, Y; Pina, M; Graille, J

    2002-08-01

    An analytical procedure was developed for regiodistribution analysis of TAG using alpha-MAG prepared by an ethyl magnesium bromide deacylation. In the present communication, the deacylation procedure is shown to lead to representative alpha-MAG, allowing the composition of the native TAG in the alpha-position to be determined directly. The composition in the beta-position can then be estimated from the composition of the alpha-MAG and TAG according to the formula 3 x TAG - 2 x alpha-MAG. The estimates are superior to those obtained using the alpha,beta-DAG and Brockerhoff calculations as they come closer to the theoretical value and have smaller SD. The present procedure, first demonstrated on a synthetic TAG, was then successfully applied to the analysis of borage oil, milkfat, and tuna oil. PMID:12371754

  2. Neurologic syndrome associated with homozygous mutation at MAG sialic acid binding site.

    PubMed

    Roda, Ricardo H; FitzGibbon, Edmond J; Boucekkine, Houda; Schindler, Alice B; Blackstone, Craig

    2016-08-01

    The MAG gene encodes myelin-associated glycoprotein (MAG), an abundant protein involved in axon-glial interactions and myelination during nerve regeneration. Several members of a consanguineous family with a clinical syndrome reminiscent of Pelizaeus-Merzbacher disease and demyelinating leukodystrophy on brain MRI were recently found to harbor a homozygous missense p.Ser133Arg MAG mutation. Here, we report two brothers from a nonconsanguineous family afflicted with progressive cognitive impairment, neuropathy, ataxia, nystagmus, and gait disorder. Exome sequencing revealed the homozygous missense mutation p.Arg118His in MAG. This Arg118 residue in immunoglobulin domain 1 is critical for sialic acid binding, providing a compelling mechanistic basis for disease pathogenesis. PMID:27606346

  3. 21 CFR 872.6010 - Abrasive device and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... excessive restorative materials, such as gold, and to smooth rough surfaces from oral restorations, such...

  4. 21 CFR 872.6010 - Abrasive device and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... excessive restorative materials, such as gold, and to smooth rough surfaces from oral restorations, such...

  5. 21 CFR 872.6010 - Abrasive device and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... excessive restorative materials, such as gold, and to smooth rough surfaces from oral restorations, such...

  6. Accessory proteins for heterotrimeric G-proteins in the kidney

    PubMed Central

    Park, Frank

    2015-01-01

    Heterotrimeric G-proteins play a fundamentally important role in regulating signal transduction pathways in the kidney. Accessory proteins are being identified as direct binding partners for heterotrimeric G-protein α or βγ subunits to promote more diverse mechanisms by which G-protein signaling is controlled. In some instances, accessory proteins can modulate the signaling magnitude, localization, and duration following the activation of cell membrane-associated receptors. Alternatively, accessory proteins complexed with their G-protein α or βγ subunits can promote non-canonical models of signaling activity within the cell. In this review, we will highlight the expression profile, localization and functional importance of these newly identified accessory proteins to control the function of select G-protein subunits under normal and various disease conditions observed in the kidney. PMID:26300785

  7. 21 CFR 876.5820 - Hemodialysis system and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer. (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air...) The dialysate delivery system consists of mechanisms that monitor and control the...

  8. 21 CFR 876.5630 - Peritoneal dialysis system and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set...

  9. 21 CFR 876.5630 - Peritoneal dialysis system and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set...

  10. 21 CFR 876.5630 - Peritoneal dialysis system and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions, and that consists of a peritoneal access device, an administration set...

  11. The clinical anatomy of accessory mental nerves and foramina.

    PubMed

    Iwanaga, Joe; Saga, Tsuyoshi; Tabira, Yoko; Nakamura, Moriyoshi; Kitashima, Sadaharu; Watanabe, Koichi; Kusukawa, Jingo; Yamaki, Koh-Ichi

    2015-10-01

    Since three-dimensional computed tomography was developed, many researchers have described accessory mental foramina. The anatomical and radiological findings have been discussed, but details of accessory mental nerves (AMNs) have only been researched in a small number of anatomical and clinical cases. For this article, we reviewed the literature relating to accessory mental foramina (AMFs) and nerves to clarify aspects important for clinical situations. The review showed that the distribution pattern of the AMN can differ according to the position of the accessory mental foramen, and the reported incidence of AMFs differs among observation methods. A review of clinical cases also revealed that injury to large AMF can result in paresthesia. This investigation did not reveal all aspects of AMNs and AMFs, but will be useful for diagnosis and treatment by many dentists and oral and maxillofacial surgeons.

  12. INTERIOR VIEW OF BATHROOM 2. SHOWING ORIGINAL TILE. CERAMIC ACCESSORIES, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR VIEW OF BATHROOM 2. SHOWING ORIGINAL TILE. CERAMIC ACCESSORIES, AND MARBLE THRESHOLD. VIEW FACING EAST. - Hickam Field, Officers' Housing Type G, 205 Seventh Street, Honolulu, Honolulu County, HI

  13. MagFRET: The First Genetically Encoded Fluorescent Mg2+ Sensor

    PubMed Central

    Oortwijn, Jorn; Aper, Stijn J. A.; Merkx, Maarten

    2013-01-01

    Magnesium has important structural, catalytic and signaling roles in cells, yet few tools exist to image this metal ion in real time and at subcellular resolution. Here we report the first genetically encoded sensor for Mg2+, MagFRET-1. This sensor is based on the high-affinity Mg2+ binding domain of human centrin 3 (HsCen3), which undergoes a transition from a molten-globular apo form to a compactly-folded Mg2+-bound state. Fusion of Cerulean and Citrine fluorescent domains to the ends of HsCen3, yielded MagFRET-1, which combines a physiologically relevant Mg2+ affinity (Kd = 148 µM) with a 50% increase in emission ratio upon Mg2+ binding due to a change in FRET efficiency between Cerulean and Citrine. Mutations in the metal binding sites yielded MagFRET variants whose Mg2+ affinities were attenuated 2- to 100-fold relative to MagFRET-1, thus covering a broad range of Mg2+ concentrations. In situ experiments in HEK293 cells showed that MagFRET-1 can be targeted to the cytosol and the nucleus. Clear responses to changes in extracellular Mg2+ concentration were observed for MagFRET-1-expressing HEK293 cells when they were permeabilized with digitonin, whereas similar changes were not observed for intact cells. Although MagFRET-1 is also sensitive to Ca2+, this affinity is sufficiently attenuated (Kd of 10 µM) to make the sensor insensitive to known Ca2+ stimuli in HEK293 cells. While the potential and limitations of the MagFRET sensors for intracellular Mg2+ imaging need to be further established, we expect that these genetically encoded and ratiometric fluorescent Mg2+ sensors could prove very useful in understanding intracellular Mg2+ homeostasis and signaling. PMID:24312622

  14. Salivary gland disorders.

    PubMed

    Wilson, Kevin F; Meier, Jeremy D; Ward, P Daniel

    2014-06-01

    Salivary gland disorders include inflammatory, bacterial, viral, and neoplastic etiologies. The presentation can be acute, recurrent, or chronic. Acute suppurative sialadenitis presents as rapid-onset pain and swelling and is treated with antibiotics, salivary massage, hydration, and sialagogues such as lemon drops or vitamin C lozenges. Viral etiologies include mumps and human immunodeficiency virus, and treatment is directed at the underlying disease. Recurrent or chronic sialadenitis is more likely to be inflammatory than infectious; examples include recurrent parotitis of childhood and sialolithiasis. Inflammation is commonly caused by an obstruction such as a stone or duct stricture. Management is directed at relieving the obstruction. Benign and malignant tumors can occur in the salivary glands and usually present as a painless solitary neck mass. Diagnosis is made by imaging (e.g., ultrasonography, computed tomography, magnetic resonance imaging) and biopsy (initially with fine-needle aspiration). Overall, most salivary gland tumors are benign and can be treated with surgical excision.

  15. Salivary gland myoepithelial carcinoma.

    PubMed

    Vilar-González, S; Bradley, K; Rico-Pérez, J; Vogiatzis, P; Golka, D; Nigam, A; Sivaramalingam, M; Kazmi, S

    2015-11-01

    Salivary gland myoepithelial carcinoma (MC) or malignant myoepithelioma is a rare entity. MC usually presents as a slow-growing painless mass arising in the parotid gland, but may involve other salivary glands. This tumour may be particularly locally aggressive, but its clinical and biological features are not yet fully understood. MC may arise from pre-existing benign lesions, such as pleomorphic adenomas or benign myoepitheliomas, or may arise de novo. It usually affects patients over 50 years old, with no gender preference. Because it is often asymptomatic, the presentation and diagnosis can be delayed by months, even years. The current WHO classification considers MC to be an intermediate- to high-grade malignancy. Other published data suggest it is likely to be a high-grade neoplasm, consistent with its aggressive behaviour. Its epidemiology, histopathological features, immunohistochemical profile, clinical behaviour and optimal management are not well understood. Following review of the current literature we aim to address these.

  16. A New Interface for the Magnetics Information Consortium (MagIC) Paleo and Rock Magnetic Database

    NASA Astrophysics Data System (ADS)

    Jarboe, N.; Minnett, R.; Koppers, A. A. P.; Tauxe, L.; Constable, C.; Shaar, R.; Jonestrask, L.

    2014-12-01

    The Magnetic Information Consortium (MagIC) database (http://earthref.org/MagIC/) continues to improve the ease of uploading data, the creation of complex searches, data visualization, and data downloads for the paleomagnetic, geomagnetic, and rock magnetic communities. Data uploading has been simplified and no longer requires the use of the Excel SmartBook interface. Instead, properly formatted MagIC text files can be dragged-and-dropped onto an HTML 5 web interface. Data can be uploaded one table at a time to facilitate ease of uploading and data error checking is done online on the whole dataset at once instead of incrementally in an Excel Console. Searching the database has improved with the addition of more sophisticated search parameters and with the ability to use them in complex combinations. Searches may also be saved as permanent URLs for easy reference or for use as a citation in a publication. Data visualization plots (ARAI, equal area, demagnetization, Zijderveld, etc.) are presented with the data when appropriate to aid the user in understanding the dataset. Data from the MagIC database may be downloaded from individual contributions or from online searches for offline use and analysis in the tab delimited MagIC text file format. With input from the paleomagnetic, geomagnetic, and rock magnetic communities, the MagIC database will continue to improve as a data warehouse and resource.

  17. Two novel elements (CFG1 and PYG1) of Mag lineage of Ty3/Gypsy retrotransposons from Zhikong scallop (Chlamys farreri) and Japanese scallop (Patinopecten yessoensis).

    PubMed

    Wang, Shi; Bao, Zhenmin; Hu, Xiaoli; Shao, Mingyu; Zhang, Lingling; Hu, Jingjie

    2008-05-01

    Two novel elements (CFG1 and PYG1) of Mag lineage of Ty3/Gypsy retrotransposons were cloned from Zhikong scallop (Chlamys farreri) and Japanese scallop (Patinopecten yessoensis). The total length of the CFG1 element is 4826 bp, including 5'-LTR (192 bp), the entire ORF (4047 bp) and 3'-LTR (189 bp). The entire ORFs of both CFG1 and PYG1 elements are composed of 1348 aa and do not have any frameshifts. Their closest relative is Jule element from the poeciliid fish (Xiphophorus maculatus). On average, the diploid genome of C. farreri contains approximately 84 copies of CFG1 elements. We summarize the major features of CFG1, PYG1 and other elements of Mag lineage of the Ty3/Gypsy group. mRNA expression of CFG1 element in larvae increases gradually before the gastrulae stage and decreases gradually afterward, whereas in adductor such expression in adductor muscle and digestive gland are lower than those in other tissues. Overall, mRNA expression of CFG1 element in the early larvae is significantly higher than that in adult tissues. In muscle tissue, while the promoter and partial GAG domain of CFG1 element are unmethylated, the partial RT domain is highly methylated. These results suggest that CFG1 expression may be controlled by a post-transcriptional gene silencing mechanism that is associated with coding-region (RT domain) methylation. PMID:17694394

  18. Pictorial essay: Salivary gland imaging

    PubMed Central

    Rastogi, Rajul; Bhargava, Sumeet; Mallarajapatna, Govindarajan Janardan; Singh, Sudhir Kumar

    2012-01-01

    Salivary glands are the first organs of digestion secreting their digestive juices into the oral cavity. Parotid, submandibular, and sublingual glands are the major paired salivary glands in the decreasing order of their size. In addition, multiple small minor salivary glands are noted randomly distributed in the upper aerodigestive tract, including paranasal sinuses and parapharyngeal spaces. The imaging is directed to the major salivary glands. Commonly used imaging methods include plain radiography and conventional sialography. Recently, high-resolution ultrasonography (HRUS) is being increasingly used for targeted salivary gland imaging. However, the advent of cross-sectional imaging techniques such as computed tomography (CT) and magnetic resonance imaging (MRI) have revolutionized the imaging of salivary glands. This article illustrates the role of imaging in evaluating the variegated disease pattern of the major salivary glands. PMID:23833425

  19. What Is Salivary Gland Cancer?

    MedlinePlus

    ... are many types of salivary gland adenocarcinomas. Acinic cell carcinoma: Most acinic cell carcinomas start in the ... cancer can develop in the salivary glands. Squamous cell carcinoma: This cancer occurs mainly in older men. ...

  20. Imaging of the salivary glands.

    PubMed

    Weissman, J L

    1995-12-01

    CT and MRI have greatly facilitated evaluation of pathology of the three pairs of major salivary glands and the hundreds of minor salivary glands. Imaging can frequently offer a specific histological diagnosis for benign and malignant neoplasms of the parotid, submandibular, and sublingual glands. Obstruction, infection, autoimmune processes, and congenital anomalies also are readily diagnosed. CT and MRI studies assess the anatomic extent of minor salivary gland neoplasms. Sialography continues to provide useful information about intrinsic abnormalities of the parotid and submandibular ducts.

  1. Anatomy of the thymus gland.

    PubMed

    Safieddine, Najib; Keshavjee, Shaf

    2011-05-01

    In the case of the thymus gland, the most common indications for resection are myasthenia gravis or thymoma. The consistency and appearance of the thymus gland make it difficult at times to discern from mediastinal fatty tissues. Having a clear understanding of the anatomy and the relationship of the gland to adjacent structures is important.

  2. MAG4 versus Alternative Techniques for Forecasting Active-Region Flare Productivity

    NASA Astrophysics Data System (ADS)

    Falconer, David; Moore, Ronald L.; Barghouty, Abdulnasser F; Khazanov, Igor

    2014-06-01

    MAG4 is a technique of forecasting an active region's rate of production of major flares in the coming few days from a free-magnetic-energy proxy. We present a statistical method of measuring the difference in performance between MAG4 and comparable alternative techniques that forecast an active region’s major-flare productivity from alternative observed aspects of the active region. We demonstrate the method by measuring the difference in performance between the “Present MAG4” technique and each of three alternative techniques, called “McIntosh Active-Region Class,” “Total Magnetic Flux,” and “Next MAG4.” We do this by using (1) the MAG4 database of magnetograms and major-flare histories of sunspot active regions, (2) the NOAA table of the major-flare productivity of each of 60 McIntosh active-region classes of sunspot active regions, and (3) five technique-performance metrics (Heidke Skill Score, True Skill Score, Percent Correct, Probability of Detection, and False Alarm Rate) evaluated from 2000 random two-by-two contingency tables obtained from the databases. We find that (1) Present MAG4 far outperforms both McIntosh Active-Region Class and Total Magnetic Flux, (2) Next MAG4 significantly outperforms Present MAG4, (3) the performance of Next MAG4 is insensitive to the forward and backward temporal windows used, in the range of one to a few days, and (4) forecasting from the free-energy proxy in combination with either any broad category of McIntosh active-region classes or any Mount Wilson active-region class gives no significant performance improvement over forecasting from the free-energy proxy alone (Present MAG4). Funding for this research came from NASA’s Game Changing Development Program, Johnson Space Center’s Space Radiation Analysis Group (SRAG), and AFOSR’s Multi-University Research Initiative. In particular, funding was facilitated by Dr. Dan Fry (NASA-JSC) and David Moore (NASA-LaRC).

  3. [Meibomian gland dysfunction].

    PubMed

    Finis, D; Schrader, S; Geerling, G

    2012-05-01

    Meibomian gland dysfunction (MGD) is a chronic disease, usually caused by obstruction of the secretory Meibomian glands. The subsequent reduction of gland secretion results in a decreased amount of lipids in the tear film. This results in a faster evaporation of the tear film and thus an evaporative dry eye. MGD alone is responsible for about 60% of all cases in combination with aqueous deficiency for a further 20% of dry eyes. While in Europe up to 20% of the population are suffering from MDD, this is true in Asia for over 60% of the population. MGD is more common in women and it incidence increases with age. It is influenced by the hormonal status as well as chemical and mechanical noxious stimuli. Additional risk factors include various skin diseases such as rosacea, acne or atopy. To diagnose MGD, particular attention should be paid to changes in the lid margin such as plugging or pouting of the ducts, thickening and telangiectasia. However, most important is the diagnostic expression of the glands. At first it should be assessed whether secretion can be caused by pressure to the eyelid against the globe and secondly the quality of the expressed secretions should be evaluated. MGD should be treated according to the severity of the disease. While in mild stages instructions for lid margin hygiene, warming and massage in combination with artificial tears might be sufficient, in more severe stages oral tetracyclin derivatives and anti-inflammatory eye drops such as steroids or CSA are necessary for successful treatment.

  4. Pediatric Salivary Gland Malignancies.

    PubMed

    Ord, Robert A; Carlson, Eric R

    2016-02-01

    Pediatric malignant salivary gland tumors are extremely rare. The percentage of malignant tumors is higher than that seen in adults, although the outcomes in terms of survival are better in pediatric patients. The mainstay of treatment is surgical excision with negative margins. This article reviews current concepts in demographics, etiology, management, and outcomes of malignant salivary tumors in children.

  5. Does the polystomatic gland exist?

    PubMed

    Imai, M; Shibata, T; Moriguchi, K; Kinbara, M

    1989-03-01

    According to the P.N.A., the N.A.J. and some scholars, the sublingual gland has the ductus sublingualis major and ductus sublinguales minores. This means that the gland is a polystomatic gland. We intended to determine whether the so-called polystomatic gland exists or not. 1. According to the P.N.A., the N.A.J. and some scholars, the gl. sublingualis has the ductus sublingualis major and ductus sublinguales minores. This means the gland is a polystomatic gland. However, the formation of one gland with plural excretory ducts is embryologically impossible, in other words, the polystomatic gland does not exist. 2. Many scholars described that the gl. sublingualis was composed of the gl. sublingualis major and g11. sublinguales minores. However, they are completely different kinds of glands. Accordingly, we suggest the terms for these glands: the g1. sublingualis and its ductus sublingualis ("major" is useless), the g11. sublinguales minores and their ductus sublinguales minores. 3. The N.A.V.J. and some scholars use the term g1. sublingualis polystomatica or parvicanalaris. However, this is a group of a number of independent glands each of which has its own excretory duct. Such a gland should not be regarded as a single gland. We suggest that the term g11. sublinguales minores and their excretory ducts should be replaced with the term the ductus sublinguales minores. 4. The g1. lingualis anterior, g1. retromolaris and g1. lacrimalis are not single glands but a group of several independent glands each of which has its own excretory duct. Accordingly, they should be termed the g11. linguales anteriores, g11. retromolares and g11. lacrimales such as the g11. labiales, g11. buccales and g11. palatinae.

  6. Intervention of D-glucose ameliorates the toxicity of streptozotocin in accessory sex organs of rat

    SciTech Connect

    Vikram, A.; Tripathi, D.N.; Ramarao, P.; Jena, G.B.

    2008-01-01

    Streptozotocin (STZ) is a naturally occurring compound isolated from Streptomyces achromogens. It is used extensively for inducing diabetes in experimental animals. Diabetes mellitus is known to have proven adverse effects on male sexual organs and their reproductive functions. The atrophy of prostate gland and other organs of the genitourinary tract were observed in experimental diabetic animals. STZ exhibits a structural resemblance to D-glucose due to the presence of sugar moiety in its structure. Pancreatic {beta}-cells mainly contain GLUT1 and GLUT2 glucose transporters. Possibly due to structural resemblance, STZ and D-glucose, share a common recognition site for entry into the {beta}-cells. The objective of the present study is to evaluate the effect of D-glucose on STZ-induced toxicity in accessory sex organs of male rats. Animals were kept on overnight fasting. One group received vehicle and served as negative control, while all other groups were given STZ (45 mg/kg). Animals that received only STZ served as positive control. The effect of D-glucose was studied on STZ treated animals with different dosage of D-glucose (250, 500, 1000 and 2000 mg/kg). Restoration of body weight, plasma glucose and plasma insulin was evident only at 1000 and 2000 mg/kg of D-glucose. The protective effect of D-glucose is evident only when it is administered simultaneously with STZ. In the present investigation, we report that simultaneous administration of D-glucose along with STZ ameliorates STZ-induced toxicity. This is evident from the restoration of accessory sex organ's weight, cellular morphology as well as insulin level.

  7. Accessory costs of seed production and the evolution of angiosperms.

    PubMed

    Lord, Janice M; Westoby, Mark

    2012-01-01

    Accessory costs of reproduction frequently equal or exceed direct investment in offspring, and can limit the evolution of small offspring sizes. Early angiosperms had minimum seed sizes, an order of magnitude smaller than their contemporaries. It has been proposed that changes to reproductive features at the base of the angiosperm clade reduced accessory costs thus removing the fitness disadvantage of small seeds. We measured accessory costs of reproduction in 25 extant gymnosperms and angiosperms, to test whether angiosperms can produce small seeds more economically than gymnosperms. Total accessory costs scaled isometrically to seed mass for angiosperms but less than isometrically for gymnosperms, so that smaller seeds were proportionally more expensive for gymnosperms to produce. In particular, costs of abortions and packaging structures were significantly higher in gymnosperms. Also, the relationship between seed:ovule ratio and seed size was negative in angiosperms but positive in gymnosperms. We argue that the carpel was a key evolutionary innovation reducing accessory costs in angiosperms by allowing sporophytic control of pre- and postzygotic mate selection and timing of resource allocation. The resulting reduction in costs of aborting unfertilized ovules or genetically inferior embryos would have lowered total reproductive costs enabling early angiosperms to evolve small seed sizes and short generation times.

  8. Magnetically separable polymer (Mag-MIP) for selective analysis of biotin in food samples.

    PubMed

    Uzuriaga-Sánchez, Rosario Josefina; Khan, Sabir; Wong, Ademar; Picasso, Gino; Pividori, Maria Isabel; Sotomayor, Maria Del Pilar Taboada

    2016-01-01

    This work presents an efficient method for the preparation of magnetic nanoparticles modified with molecularly imprinted polymers (Mag-MIP) through core-shell method for the determination of biotin in milk food samples. The functional monomer acrylic acid was selected from molecular modeling, EGDMA was used as cross-linking monomer and AIBN as radical initiator. The Mag-MIP and Mag-NIP were characterized by FTIR, magnetic hysteresis, XRD, SEM and N2-sorption measurements. The capacity of Mag-MIP for biotin adsorption, its kinetics and selectivity were studied in detail. The adsorption data was well described by Freundlich isotherm model with adsorption equilibrium constant (KF) of 1.46 mL g(-1). The selectivity experiments revealed that prepared Mag-MIP had higher selectivity toward biotin compared to other molecules with different chemical structure. The material was successfully applied for the determination of biotin in diverse milk samples using HPLC for quantification of the analyte, obtaining the mean value of 87.4% recovery.

  9. SuperMAG: The Road to 115,000 Plots Viewed in a Month

    NASA Astrophysics Data System (ADS)

    Barnes, R. J.; Gjerloev, J. W.

    2010-12-01

    SuperMAG is a global collaboration that provides ground magnetic field perturbations from a long list of stations in the same coordinate system, identical time resolution and with a common baseline removal approach. This unique high quality dataset provides a continuous and nearly global monitoring of the ground magnetic field perturbation. Before SuperMAG, global or even local studies required painstaking and labor-intensive data-handling, which effectively limited research. Analysts faced several inherent complications: confusing or even unknown coordinate systems, a multitude of data artifacts and errors, unknown baselines, and even difficulties obtaining data. These problems have resulted in a serious underutilization of data from magnetometers. The SuperMAG service is a truly global initiative including a long list of organizations and agencies providing data obtained from more than 300 ground based stations. The website includes a list of user-friendly data products, data downloads and other helpful tools. To compliment the measured ground magnetic field perturbations SuperMAG now includes global auroral images and solar wind data. The talk will further focus on lessons learned in the process of developing this community service. One lesson learned is that the validity of SuperMAG or any other type of virtual observatory is not defined by the funding agencies or the website developers themselves but by the users.

  10. A background correction algorithm for Van Allen Probes MagEIS electron flux measurements

    SciTech Connect

    Claudepierre, S. G.; O'Brien, T. P.; Blake, J. B.; Fennell, J. F.; Roeder, J. L.; Clemmons, J. H.; Looper, M. D.; Mazur, J. E.; Mulligan, T. M.; Spence, H. E.; Reeves, G. D.; Friedel, R. H. W.; Henderson, M. G.; Larsen, B. A.

    2015-07-14

    We describe an automated computer algorithm designed to remove background contamination from the Van Allen Probes Magnetic Electron Ion Spectrometer (MagEIS) electron flux measurements. We provide a detailed description of the algorithm with illustrative examples from on-orbit data. We find two primary sources of background contamination in the MagEIS electron data: inner zone protons and bremsstrahlung X-rays generated by energetic electrons interacting with the spacecraft material. Bremsstrahlung X-rays primarily produce contamination in the lower energy MagEIS electron channels (~30–500 keV) and in regions of geospace where multi-M eV electrons are present. Inner zone protons produce contamination in all MagEIS energy channels at roughly L < 2.5. The background-corrected MagEIS electron data produce a more accurate measurement of the electron radiation belts, as most earlier measurements suffer from unquantifiable and uncorrectable contamination in this harsh region of the near-Earth space environment. These background-corrected data will also be useful for spacecraft engineering purposes, providing ground truth for the near-Earth electron environment and informing the next generation of spacecraft design models (e.g., AE9).

  11. Improvements to the Magnetics Information Consortium (MagIC) Paleo and Rock Magnetic Database

    NASA Astrophysics Data System (ADS)

    Jarboe, N.; Minnett, R.; Tauxe, L.; Koppers, A. A. P.; Constable, C.; Jonestrask, L.

    2015-12-01

    The Magnetic Information Consortium (MagIC) database (http://earthref.org/MagIC/) continues to improve the ease of data uploading and editing, the creation of complex searches, data visualization, and data downloads for the paleomagnetic, geomagnetic, and rock magnetic communities. Online data editing is now available and the need for proprietary spreadsheet software is therefore entirely negated. The data owner can change values in the database or delete entries through an HTML 5 web interface that resembles typical spreadsheets in behavior and uses. Additive uploading now allows for additions to data sets to be uploaded with a simple drag and drop interface. Searching the database has improved with the addition of more sophisticated search parameters and with the facility to use them in complex combinations. A comprehensive summary view of a search result has been added for increased quick data comprehension while a raw data view is available if one desires to see all data columns as stored in the database. Data visualization plots (ARAI, equal area, demagnetization, Zijderveld, etc.) are presented with the data when appropriate to aid the user in understanding the dataset. MagIC data associated with individual contributions or from online searches may be downloaded in the tab delimited MagIC text file format for susbsequent offline use and analysis. With input from the paleomagnetic, geomagnetic, and rock magnetic communities, the MagIC database will continue to improve as a data warehouse and resource.

  12. MagAO: Status and on-sky performance of the Magellan adaptive optics system

    NASA Astrophysics Data System (ADS)

    Morzinski, Katie M.; Close, Laird M.; Males, Jared R.; Kopon, Derek; Hinz, Phil M.; Esposito, Simone; Riccardi, Armando; Puglisi, Alfio; Pinna, Enrico; Briguglio, Runa; Xompero, Marco; Quirós-Pacheco, Fernando; Bailey, Vanessa; Follette, Katherine B.; Rodigas, T. J.; Wu, Ya-Lin; Arcidiacono, Carmelo; Argomedo, Javier; Busoni, Lorenzo; Hare, Tyson; Uomoto, Alan; Weinberger, Alycia

    2014-07-01

    MagAO is the new adaptive optics system with visible-light and infrared science cameras, located on the 6.5-m Magellan "Clay" telescope at Las Campanas Observatory, Chile. The instrument locks on natural guide stars (NGS) from 0th to 16th R-band magnitude, measures turbulence with a modulating pyramid wavefront sensor binnable from 28×28 to 7×7 subapertures, and uses a 585-actuator adaptive secondary mirror (ASM) to provide at wavefronts to the two science cameras. MagAO is a mutated clone of the similar AO systems at the Large Binocular Telescope (LBT) at Mt. Graham, Arizona. The high-level AO loop controls up to 378 modes and operates at frame rates up to 1000 Hz. The instrument has two science cameras: VisAO operating from 0.5-1μm and Clio2 operating from 1-5 μm. MagAO was installed in 2012 and successfully completed two commissioning runs in 2012-2013. In April 2014 we had our first science run that was open to the general Magellan community. Observers from Arizona, Carnegie, Australia, Harvard, MIT, Michigan, and Chile took observations in collaboration with the MagAO instrument team. Here we describe the MagAO instrument, describe our on-sky performance, and report our status as of summer 2014.

  13. A background correction algorithm for Van Allen Probes MagEIS electron flux measurements

    DOE PAGES

    Claudepierre, S. G.; O'Brien, T. P.; Blake, J. B.; Fennell, J. F.; Roeder, J. L.; Clemmons, J. H.; Looper, M. D.; Mazur, J. E.; Mulligan, T. M.; Spence, H. E.; et al

    2015-07-14

    We describe an automated computer algorithm designed to remove background contamination from the Van Allen Probes Magnetic Electron Ion Spectrometer (MagEIS) electron flux measurements. We provide a detailed description of the algorithm with illustrative examples from on-orbit data. We find two primary sources of background contamination in the MagEIS electron data: inner zone protons and bremsstrahlung X-rays generated by energetic electrons interacting with the spacecraft material. Bremsstrahlung X-rays primarily produce contamination in the lower energy MagEIS electron channels (~30–500 keV) and in regions of geospace where multi-M eV electrons are present. Inner zone protons produce contamination in all MagEIS energymore » channels at roughly L < 2.5. The background-corrected MagEIS electron data produce a more accurate measurement of the electron radiation belts, as most earlier measurements suffer from unquantifiable and uncorrectable contamination in this harsh region of the near-Earth space environment. These background-corrected data will also be useful for spacecraft engineering purposes, providing ground truth for the near-Earth electron environment and informing the next generation of spacecraft design models (e.g., AE9).« less

  14. Interdisciplinary Collaboration amongst Colleagues and between Initiatives with the Magnetics Information Consortium (MagIC) Database

    NASA Astrophysics Data System (ADS)

    Minnett, R.; Koppers, A. A. P.; Jarboe, N.; Tauxe, L.; Constable, C.; Jonestrask, L.; Shaar, R.

    2014-12-01

    Earth science grand challenges often require interdisciplinary and geographically distributed scientific collaboration to make significant progress. However, this organic collaboration between researchers, educators, and students only flourishes with the reduction or elimination of technological barriers. The Magnetics Information Consortium (http://earthref.org/MagIC/) is a grass-roots cyberinfrastructure effort envisioned by the geo-, paleo-, and rock magnetic scientific community to archive their wealth of peer-reviewed raw data and interpretations from studies on natural and synthetic samples. MagIC is dedicated to facilitating scientific progress towards several highly multidisciplinary grand challenges and the MagIC Database team is currently beta testing a new MagIC Search Interface and API designed to be flexible enough for the incorporation of large heterogeneous datasets and for horizontal scalability to tens of millions of records and hundreds of requests per second. In an effort to reduce the barriers to effective collaboration, the search interface includes a simplified data model and upload procedure, support for online editing of datasets amongst team members, commenting by reviewers and colleagues, and automated contribution workflows and data retrieval through the API. This web application has been designed to generalize to other databases in MagIC's umbrella website (EarthRef.org) so the Geochemical Earth Reference Model (http://earthref.org/GERM/) portal, Seamount Biogeosciences Network (http://earthref.org/SBN/), EarthRef Digital Archive (http://earthref.org/ERDA/) and EarthRef Reference Database (http://earthref.org/ERR/) will benefit from its development.

  15. Labial salivary gland tumors.

    PubMed

    Neville, B W; Damm, D D; Weir, J C; Fantasia, J E

    1988-05-15

    A study was conducted on labial salivary gland tumors from four oral pathology laboratories. Of the 103 identified tumors, 87 (84.5%) were from the upper lip, whereas 16 (15.5%) were from the lower lip. Of the 87 upper lip tumors, 80 (92.0%) were benign. Forty-three of these were monomorphic adenomas and 37 were pleomorphic adenomas. Seven malignant tumors of the upper lip were as follows: four adenoid cystic carcinomas, two acinic cell carcinomas, and one adenocarcinoma. Of the 16 lower lip tumors, 15 (93.8%) were malignant. Thirteen of these were mucoepidermoid carcinomas and two were acinic cell carcinomas. The only benign lower lip tumor was an intraductal papilloma. These results confirm the findings of previous investigations, showing that minor salivary gland tumors are much more common in the upper lip than the lower lip, but that lower lip tumors are more likely to be malignant.

  16. Stoma appliances and accessories: getting it right for the patient.

    PubMed

    Burch, Jennie

    This article will examine some of the appliances and accessories that can be used to care for a stoma. There are three types of stoma that can be surgically formed and each will be discussed. Furthermore, there will be brief explanations of why stomas might be formed and what the output from each stoma type will be. Complications are associated with stomas, such as sore skin, which is commonly seen within the first few months after the stoma is formed. This important topic is examined and some of the accessories that can be used to treat these issues will be explored. To aid the reader to undertake their own research on the topic, the websites from some of the stoma manufacturers are included. These websites contain more details about appliances, accessories and information for people with a stoma that can be of benefit to nurses too. PMID:25251316

  17. [Surgical treatment strategy for flatfoot related with accessory navicular].

    PubMed

    Deng, Yin-shuan; Gao, Qiu-ming; Zhen, Ping; Tang, Kang-lai

    2015-02-01

    Accessory navicular source flatfoot is one of the foot deformity of clinical common disease,its treatment method is more controversial, differences in clinical efficacy of different surgical methods, according to accessory navicular source flatfoot symptoms of surgical treatment,there is no uniform standard, around a pair of accessory navicular excision how to reconstruct the arch produced a series of operation methods, the clinical curative effect of different operative methods produce also different, how to develop the operation strategy, choose operation method, and after acessory navicular excision whether to rebuild posterior tibial tendon, how to rebuild, the problems such as how to rebuild is the research hotspot and difficulty, looking forward to further research.

  18. Case report: accessory head of the deep forearm flexors

    PubMed Central

    JONES, M.; ABRAHAMS, P. H.; SAÑUDO, J. R.

    1997-01-01

    In 1813 Gantzer described 2 accessory muscles in the human forearm which bear his name (Wood, 1868; Macalister, 1875) and these have subsequently been reported with variable attachments (Wood, 1868; Macalister, 1875; Turner, 1879; Schäfer & Thane, 1894; Le Double, 1897; Dykes & Anson, 1944; Mangini, 1960; Malhotra et al. 1982; Kida, 1988; Tountas & Bergman, 1993). The accessory heads of the deep flexors of the forearm (Gantzer's muscles) have been described as 2 different small bellies which insert either into FPL or FDP. There are no previous reports which have mentioned the existence of an accessory muscle which inserts into both of the 2 deep flexors of the forearm as in the case presented here. PMID:9306208

  19. Endocytic Accessory Factors and Regulation of Clathrin-Mediated Endocytosis

    PubMed Central

    Merrifield, Christien J.; Kaksonen, Marko

    2014-01-01

    Up to 60 different proteins are recruited to the site of clathrin-mediated endocytosis in an ordered sequence. These accessory proteins have roles during all the different stages of clathrin-mediated endocytosis. First, they participate in the initiation of the endocytic event, thereby determining when and where endocytic vesicles are made; later they are involved in the maturation of the clathrin coat, recruitment of specific cargo molecules, bending of the membrane, and finally in scission and uncoating of the nascent vesicle. In addition, many of the accessory components are involved in regulating and coupling the actin cytoskeleton to the endocytic membrane. We will discuss the different accessory components and their various roles. Most of the data comes from studies performed with cultured mammalian cells or yeast cells. The process of endocytosis is well conserved between these different organisms, but there are also many interesting differences that may shed light on the mechanistic principles of endocytosis. PMID:25280766

  20. Dynamic behavior of {sup 110m}Ag in sheep tissues

    SciTech Connect

    Beresford, N.A.; Howard, B.J.; Mayes, R.W.

    1994-04-01

    The transfer coefficient of {sup 110m}Ag to a range of sheep tissues and its biological half-life in these tissues has been determined. Liver was shown to be the major site of {sup 110m}Ag deposition and retention, with a transfer coefficient of F{sub f} 7.1 d kg{sup -1} and a biological half-life of 79 d. These results also suggests that previous estimates of the transfer of silver to muscle were too high, although further work would be required to confirm this. There is a need for accurate data which can be used to predict the transfer of {sup 110m}Ag to food-producing animals.

  1. Bronchial mucous gland tumours.

    PubMed

    Spencer, H

    1979-07-27

    Tumours arising in the bronchial mucous glands closely resemble tumours arising in the mixed salivary glands. Bronchial mucous gland tumours account for less than 0.5 per cent of all lung tumours. Twenty six tumours are reviewed and they have been divided into five types, (a) adenoidcystic carcinomas, (b) muco-epidermoid tumors, (c) mixed (pleomorphic) tumors, (d) cystadenomas and (f) oxyphilic adenoma. The clinical features, and postoperative course of the patients are reviewed. Adenocystic carcinomas, arising in the bronchus frequently involve the neighbouring trachea and spread mainly by direct infiltration. Most muco-epidermoid bronchial tumours were confined to young persons, and the only malignant muco-epidermoid tumour occurred in an elderly person. The prognosis in young persons is good provided the tumours are completely excised. The two mixed bronchial tumours resembled their salivary counterparts and one subsequently behaved as a carcinoma and metastasised. Bronchial cystadenomas all proved to be benign tumours but in two cases were associated with surface papillary proliferation. The only example of an oxyphil cell adenoma was discovered at post mortem examination. The histogenesis of the tumours is considered.

  2. Disposable MagLev centrifugal blood pump utilizing a cone-shaped impeller.

    PubMed

    Hijikata, Wataru; Sobajima, Hideo; Shinshi, Tadahiko; Nagamine, Yasuyuki; Wada, Suguru; Takatani, Setsuo; Shimokohbe, Akira

    2010-08-01

    To enhance the durability and reduce the blood trauma of a conventional blood pump with a cone-shaped impeller, a magnetically levitated (MagLev) technology has been applied to the BioPump BPX-80 (Medtronic Biomedicus, Inc., Minneapolis, MN, USA), whose impeller is supported by a mechanical bearing. The MagLev BioPump (MagLev BP), which we have developed, has a cone-shaped impeller, the same as that used in the BPX-80. The suspension and driving system, which is comprised of two degrees of freedom, radial-controlled magnetic bearing, and a simply structured magnetic coupling, eliminates any physical contact between the impeller and the housing. To reduce both oscillation of the impeller and current in the coils, the magnetic bearing system utilizes repetitive and zero-power compensators. In this article, we present the design of the MagLev mechanism, measure the levitational accuracy of the impeller and pressure-flow curves (head-quantity [HQ] characteristics), and describe in vitro experiments designed to measure hemolysis. For the flow-induced hemolysis of the initial design to be reduced, the blood damage index was estimated by using computational fluid dynamics (CFD) analysis. Stable rotation of the impeller in a prototype MagLev BP from 0 to 2750 rpm was obtained, yielding a flow rate of 5 L/min against a head pressure in excess of 250 mm Hg. Because the impeller of the prototype MagLev BP is levitated without contact, the normalized index of hemolysis was 10% less than the equivalent value with the BPX-80. The results of the CFD analysis showed that the shape of the outlet and the width of the fluid clearances have a large effect on blood damage. The prototype MagLev BP satisfied the required HQ characteristics (5 L/min, 250 mm Hg) for extracorporeal circulation support with stable levitation of the impeller and showed an acceptable level of hemolysis. The simulation results of the CFD analysis indicated the possibility of further reducing the blood damage of

  3. Illuminating the Depths of the MagIC (Magnetics Information Consortium) Database

    NASA Astrophysics Data System (ADS)

    Koppers, A. A. P.; Minnett, R.; Jarboe, N.; Jonestrask, L.; Tauxe, L.; Constable, C.

    2015-12-01

    The Magnetics Information Consortium (http://earthref.org/MagIC/) is a grass-roots cyberinfrastructure effort envisioned by the paleo-, geo-, and rock magnetic scientific community. Its mission is to archive their wealth of peer-reviewed raw data and interpretations from magnetics studies on natural and synthetic samples. Many of these valuable data are legacy datasets that were never published in their entirety, some resided in other databases that are no longer maintained, and others were never digitized from the field notebooks and lab work. Due to the volume of data collected, most studies, modern and legacy, only publish the interpreted results and, occasionally, a subset of the raw data. MagIC is making an extraordinary effort to archive these data in a single data model, including the raw instrument measurements if possible. This facilitates the reproducibility of the interpretations, the re-interpretation of the raw data as the community introduces new techniques, and the compilation of heterogeneous datasets that are otherwise distributed across multiple formats and physical locations. MagIC has developed tools to assist the scientific community in many stages of their workflow. Contributors easily share studies (in a private mode if so desired) in the MagIC Database with colleagues and reviewers prior to publication, publish the data online after the study is peer reviewed, and visualize their data in the context of the rest of the contributions to the MagIC Database. From organizing their data in the MagIC Data Model with an online editable spreadsheet, to validating the integrity of the dataset with automated plots and statistics, MagIC is continually lowering the barriers to transforming dark data into transparent and reproducible datasets. Additionally, this web application generalizes to other databases in MagIC's umbrella website (EarthRef.org) so that the Geochemical Earth Reference Model (http://earthref.org/GERM/) portal, Seamount Biogeosciences

  4. The MagIC Online Database: Improving the Archive Quality via a New Review System

    NASA Astrophysics Data System (ADS)

    Constable, C.; Minnett, R.; Koppers, A. A.; Tauxe, L.; Jarboe, N. A.

    2011-12-01

    The Magnetics Information Consortium (MagIC) is committed to providing the paleomagnetic, rock magnetic, and affiliated scientific communities on-line access to peer-reviewed, published, and raw data, and interpretations, along with online analytics and visualization tools. The MagIC Database (http://earthref.org/MAGIC/) is growing rapidly with new rock and paleomagnetic datasets being uploaded daily. Users can upload contributions for private viewing in the context of published data in the MagIC Database and can elect to share an unpublished dataset with a small group of users (e.g. collaborators, journal reviewers, editors, etc.). Once the data are published, the contribution can be associated with a citable reference and made visible to the general public. Rock and paleomagnetic studies vary considerably in complexity and types of results. To accommodate these variable datasets, the MagIC Data Model has evolved into a large collection of tables with hundreds of fields available. Many of these are recommended for use, but not required, providing great flexibility to accommodate minimal information available from legacy datasets at the same time as detailed modern studies. These published and contributed results are priceless to the scientific community, but are not easily accessible for further use without appropriate metadata describing the methods employed in the study. MagIC has developed an internal review system to rapidly assess the accuracy and completeness of the metadata used and to ensure appropriate placement and descriptions of data in the contributions. Experts in the field have volunteered as MagIC editors and reviewers: they comment on the technicalities of archiving the data, (not their scientific merit which remains a task for the journal peer-review system), and provide feedback to the contributor. Successfully reviewed contributions are free of data entry errors and misunderstandings about the data model, and fully document the methods in the

  5. MAG4 Versus Alternative Techniques for Forecasting Active-Region Flare Productivity

    NASA Technical Reports Server (NTRS)

    Falconer, David A.; Moore, Ronald L.; Barghouty, Abdulnasser F.; Khazanov, Igor

    2014-01-01

    MAG4 (Magnetogram Forecast), developed originally for NASA/SRAG (Space Radiation Analysis Group), is an automated program that analyzes magnetograms from the HMI (Helioseismic and Magnetic Imager) instrument on NASA SDO (Solar Dynamics Observatory), and automatically converts the rate (or probability) of major flares (M- and X-class), Coronal Mass Ejections (CMEs), and Solar Energetic Particle Events. MAG4 does not forecast that a flare will occur at a particular time in the next 24 or 48 hours; rather the probability of one occurring.

  6. Multiplex detection of plant pathogens through the Luminex MagPlex bead system.

    PubMed

    van der Vlugt, René A A; van Raaij, Henry; de Weerdt, Marjanne; Bergervoet, Jan H W

    2015-01-01

    Here we describe a versatile multiplex method for both the serological and molecular detection of plant pathogens. The Luminex MagPlex bead system uses small paramagnetic microspheres ("beads"), either coated with specific antibodies or oligonucleotides, which capture respectively viruses and/or bacteria or PCR products obtained from their genetic material. The Luminex MagPlex bead system allows true multiplex detection of up to 500 targets in a single sample on a routine basis. The liquid suspension nature of the method significantly improves (1) assay speed, (2) detection limits and (3) dynamic range. It can also considerably reduce labor and consumables costs. PMID:25981262

  7. Comparison between pulsed MIG and short-circuit MAG on economical aspects for structural building

    SciTech Connect

    Scotti, A.; Pereira, W.A.

    1996-12-01

    In this work is presented a comparison between Pulsed MIG and Short-circuit MAG processes concerning economical and operational aspects. A systematic experimental procedure was carried-out so that the response to variation of travel speed, mean current and contact tip-to-work distance could be assessed within the same range. The operational envelopes were built taking into account lack of fusion and lack of penetration. Deposition rate and deposition efficiency were raised to evaluate productivity. The results showed that short-circuit MAG has a broader operational envelop than Pulsed MIG, but the latter, despite the narrower range, provides more productivity.

  8. Continuous Intraoperative Neuromonitoring (C-IONM) Technique with the Automatic Periodic Stimulating (APS) Accessory for Conventional and Endoscopic Thyroid Surgery.

    PubMed

    Dionigi, Gianlorenzo; Chiang, Feng-Yu; Hui, Sun; Wu, Chei-Wei; Xiaoli, Liu; Ferrari, Cesare Carlo; Mangano, Alberto; Lianos, Georgios D; Leotta, Andrea; Lavazza, Matteo; Frattini, Francesco; Annoni, Matteo; Rausei, Stefano; Boni, Luigi; Kim, Hoon Yub

    2015-05-01

    One of the most important trends in intraoperative neural monitoring (IONM) in thyroid surgery is currently the real-time monitoring of the vagus nerve (VN) in order to prevent recurrent laryngeal nerve (RLN) iatrogenic damages. Notably, continuous intraoperative neuromonitoring (C-IONM) seems to be superior to intermitted intraoperative neural monitoring (I-IONM) because it enhances standardization by permanent vagus nerve (VN) stimulation, and it provides entire and constant RLN function monitoring as the surgeon dissects and removes the thyroid gland. It also has to be highlighted that the surgical maneuvers for the automatic periodic stimulating (APS) placement must be accurate and standardized in order to avoid a potential iatrogenic morbidity on the VN function. We recommend the experienced surgeon be very careful in each step, with cautious dissection. With this review article we provide a comprehensive analyses of C-IONM technique with the APS accessory for conventional and endoscopic thyroid surgery. PMID:26054997

  9. Continuous Intraoperative Neuromonitoring (C-IONM) Technique with the Automatic Periodic Stimulating (APS) Accessory for Conventional and Endoscopic Thyroid Surgery.

    PubMed

    Dionigi, Gianlorenzo; Chiang, Feng-Yu; Hui, Sun; Wu, Chei-Wei; Xiaoli, Liu; Ferrari, Cesare Carlo; Mangano, Alberto; Lianos, Georgios D; Leotta, Andrea; Lavazza, Matteo; Frattini, Francesco; Annoni, Matteo; Rausei, Stefano; Boni, Luigi; Kim, Hoon Yub

    2015-05-01

    One of the most important trends in intraoperative neural monitoring (IONM) in thyroid surgery is currently the real-time monitoring of the vagus nerve (VN) in order to prevent recurrent laryngeal nerve (RLN) iatrogenic damages. Notably, continuous intraoperative neuromonitoring (C-IONM) seems to be superior to intermitted intraoperative neural monitoring (I-IONM) because it enhances standardization by permanent vagus nerve (VN) stimulation, and it provides entire and constant RLN function monitoring as the surgeon dissects and removes the thyroid gland. It also has to be highlighted that the surgical maneuvers for the automatic periodic stimulating (APS) placement must be accurate and standardized in order to avoid a potential iatrogenic morbidity on the VN function. We recommend the experienced surgeon be very careful in each step, with cautious dissection. With this review article we provide a comprehensive analyses of C-IONM technique with the APS accessory for conventional and endoscopic thyroid surgery.

  10. Sialolipoma of the parotid gland.

    PubMed

    Doğan, Sedat; Can, Ilknur Haberal; Unlü, Ilhan; Süngü, Nuran; Gönültaş, Mehmet Alparslan; Samim, Ethem Erdal

    2009-05-01

    A 33-year-old male patient with a slow-growing, painless, well-circumscribed soft tissue mass on the left parotid region is presented. The clinical impression was that of a benign salivary gland tumor. The tumor was situated in the superficial lobe of the gland, and a superficial parotidectomy was performed, with preservation of the facial nerve. Histopathologic examination results revealed a sialolipoma of the parotid gland and a lesion that consisted of both mature adipose tissue and glandular elements. Sialolipomas share similar clinical features with conventional lipomas of the salivary glands. Preoperative diagnosis is generally difficult, and computed tomographic scanning is useful in defining these benign parotid gland masses. Superficial parotidectomy is the usual surgical treatment for parotid gland superficial lobe lipomas, with near-total absence of recurrence.

  11. [Tumors of the salivary glands].

    PubMed

    Halimi, P; Gardner, M; Petit, F

    2005-06-01

    Tumors of salivary glands arise mainly from the parotid gland. Magnetic Resonance Imaging (MRI) is mandatory not only to localize precisely the tumor within the gland but also to differentiate between benign and malignant neoplasms, in competition with cytology in fine-needle aspiration biopsy. Tumors without risk of transformation, such as adenolymphoma, are not systematically operated on. Indications of roentgenotherapy and irradiation volumes depend on histologic type, localisation and size of the tumor.

  12. [Tumor of the Parotid Gland].

    PubMed

    Pötzl, Teresa; Iselin, Sabine; Husner, Alexander

    2016-05-11

    Salivary gland tumors are a rare, histologically heterogeneous group of tumors which constitute approximately 4–6 % of all head and neck neoplasms. In 2/3 of cases they are benign, especially in the parotid gland. We report about a rare tumor of the parotid gland presenting as an extraskeletal chondroma. Histologically there were multiple S 100 protein-positive nests of chondrocytes. The externally completed cytology suspected a pleomorphic adenoma, nevertheless, the final histopathological findings showed another tumor entity.

  13. 21 CFR 884.6190 - Assisted reproductive microscopes and microscope accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction.... Assisted reproduction microscopes and microscope accessories (excluding microscope stage warmers, which are classified under assisted reproduction accessories) are optical instruments used to enlarge images of...

  14. 21 CFR 884.6190 - Assisted reproductive microscopes and microscope accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction.... Assisted reproduction microscopes and microscope accessories (excluding microscope stage warmers, which are classified under assisted reproduction accessories) are optical instruments used to enlarge images of...

  15. 21 CFR 884.6190 - Assisted reproductive microscopes and microscope accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction.... Assisted reproduction microscopes and microscope accessories (excluding microscope stage warmers, which are classified under assisted reproduction accessories) are optical instruments used to enlarge images of...

  16. 21 CFR 884.6190 - Assisted reproductive microscopes and microscope accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction.... Assisted reproduction microscopes and microscope accessories (excluding microscope stage warmers, which are classified under assisted reproduction accessories) are optical instruments used to enlarge images of...

  17. 21 CFR 884.6190 - Assisted reproductive microscopes and microscope accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Assisted Reproduction.... Assisted reproduction microscopes and microscope accessories (excluding microscope stage warmers, which are classified under assisted reproduction accessories) are optical instruments used to enlarge images of...

  18. [Meibomian gland dysfunction--review].

    PubMed

    Nowińska, Anna; Wylegała, Edward; Tarnawska, Dorota; Janiszewska, Dominika; Dobrowolskia, Dariusz

    2012-01-01

    Meibomian gland dysfunction is a common ocular disorder affecting from 39 to 50% of population. Despite that, so far a pathophysiology path of the disease remains unknown, moreover there is no distinct border between physiology and the disease. There has been no clear diagnostic criteria. The purpose of this review was to combine a current knowledge of Meibomian gland anatomy, Meibomian gland dysfunction epidemiology, as well as presenting current definition, nomenclature, classification and diagnostic criteria. The importance of diagnosis associated with conditions such as aqueous tear deficiency, seborrheic dermatitis, and rosacea is emphasized. The available treatment methods are discussed. Meibomian gland dysfunction, blepharitis, dry eye syndrome.

  19. Taxonomy of salivary gland neoplasm.

    PubMed

    Sreeja, C; Shahela, Tanveer; Aesha, Syeda; Satish, Muthu Kumar

    2014-03-01

    Classification of neoplasms of any organ should be predicted on the patterns of differentiation that reflect the organization and cell types of the parental tissue. The ability to classify a neoplasm instills confidence in its predicted biologic behavior and the selection of treatment. There has not been a single universally used classification system for salivary gland tumor. Histogenetic and morphogenetic concepts and the developing information on various molecular parameters will have significant influence on the classification of salivary glands tumors. In this article we would highlight the histogenetic and morphogenetic concepts in salivary gland neoplasms and elaborate on the taxonomic system of classification of salivary gland neoplasms. PMID:24783163

  20. Taxonomy of Salivary Gland Neoplasm

    PubMed Central

    Sreeja, C.; Shahela, Tanveer; Aesha, Syeda; Satish, Muthu Kumar

    2014-01-01

    Classification of neoplasms of any organ should be predicted on the patterns of differentiation that reflect the organization and cell types of the parental tissue. The ability to classify a neoplasm instills confidence in its predicted biologic behavior and the selection of treatment. There has not been a single universally used classification system for salivary gland tumor. Histogenetic and morphogenetic concepts and the developing information on various molecular parameters will have significant influence on the classification of salivary glands tumors. In this article we would highlight the histogenetic and morphogenetic concepts in salivary gland neoplasms and elaborate on the taxonomic system of classification of salivary gland neoplasms. PMID:24783163

  1. Four accessory (supernumerary) intrathoracic ribs: a case report.

    PubMed

    Prados, Jose; Archilla, Francisco; Melguizo, Consolación; Aranega, Antonia

    2013-09-01

    Accessory (supernumerary) intrathoracic ribs are a very rare congenital disorder. Here, we present the first case of multiple supernumerary intrathoracic ribs in an adult, which are present consecutively between ribs 1 and 4 and without articulation with the vertebrae. Despite this, anatomical variation is usually silent and accidentally discovered; its knowledge can prevent confusion with other structures during imaging diagnostic techniques of thoracic pathologies.

  2. 21 CFR 876.5900 - Ostomy pouch and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... attached to the patient's skin by an adhesive material and that is intended for use as a receptacle for... generic type of device and its accessories includes the ostomy pouch, ostomy adhesive, the disposable... bag, ostomy drainage bag with adhesive, stomal bag, ostomy protector, and the ostomy size...

  3. 21 CFR 876.5900 - Ostomy pouch and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... attached to the patient's skin by an adhesive material and that is intended for use as a receptacle for... generic type of device and its accessories includes the ostomy pouch, ostomy adhesive, the disposable... bag, ostomy drainage bag with adhesive, stomal bag, ostomy protector, and the ostomy size...

  4. 21 CFR 876.5900 - Ostomy pouch and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... attached to the patient's skin by an adhesive material and that is intended for use as a receptacle for... generic type of device and its accessories includes the ostomy pouch, ostomy adhesive, the disposable... bag, ostomy drainage bag with adhesive, stomal bag, ostomy protector, and the ostomy size...

  5. 21 CFR 876.5900 - Ostomy pouch and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... attached to the patient's skin by an adhesive material and that is intended for use as a receptacle for... generic type of device and its accessories includes the ostomy pouch, ostomy adhesive, the disposable... bag, ostomy drainage bag with adhesive, stomal bag, ostomy protector, and the ostomy size...

  6. 21 CFR 884.1690 - Hysteroscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... direct viewing of the cervical canal and the uterine cavity by a telescopic system introduced into the... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have portals for electrosurgical, laser, or other power sources. Such hysteroscope accessory...

  7. 21 CFR 884.1690 - Hysteroscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... direct viewing of the cervical canal and the uterine cavity by a telescopic system introduced into the... specialized instrument or device delivery system; do not have adapters, connectors, channels, or do not have portals for electrosurgical, laser, or other power sources. Such hysteroscope accessory...

  8. 14 CFR 121.251 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Engine accessory section diaphragm. 121.251... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.251 Engine... complies with § 121.247 must be provided on air-cooled engines to isolate the engine power section and...

  9. 14 CFR 121.251 - Engine accessory section diaphragm.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Engine accessory section diaphragm. 121.251... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.251 Engine... complies with § 121.247 must be provided on air-cooled engines to isolate the engine power section and...

  10. 21 CFR 876.5820 - Hemodialysis system and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system..., conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate... (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery...

  11. 21 CFR 884.2740 - Perinatal monitoring system and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Perinatal monitoring system and accessories. 884.2740 Section 884.2740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... heart rate by means of combining and coordinating uterine contraction and fetal heart monitors...

  12. 21 CFR 884.2740 - Perinatal monitoring system and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Perinatal monitoring system and accessories. 884.2740 Section 884.2740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... heart rate by means of combining and coordinating uterine contraction and fetal heart monitors...

  13. 21 CFR 884.2740 - Perinatal monitoring system and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Perinatal monitoring system and accessories. 884.2740 Section 884.2740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... heart rate by means of combining and coordinating uterine contraction and fetal heart monitors...

  14. 21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... phonocardiographic monitor is a device designed to detect, measure, and record fetal heart sounds electronically,...

  15. 21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... phonocardiographic monitor is a device designed to detect, measure, and record fetal heart sounds electronically,...

  16. 19 CFR 10.537 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 1 2013-04-01 2013-04-01 false Accessories, spare parts, or tools. 10.537 Section 10.537 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY ARTICLES CONDITIONALLY FREE, SUBJECT TO A REDUCED RATE, ETC. United...

  17. 19 CFR 10.537 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 1 2011-04-01 2011-04-01 false Accessories, spare parts, or tools. 10.537 Section 10.537 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY ARTICLES CONDITIONALLY FREE, SUBJECT TO A REDUCED RATE, ETC. United...

  18. 19 CFR 10.537 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 1 2012-04-01 2012-04-01 false Accessories, spare parts, or tools. 10.537 Section 10.537 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY ARTICLES CONDITIONALLY FREE, SUBJECT TO A REDUCED RATE, ETC. United...

  19. 19 CFR 10.537 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Accessories, spare parts, or tools. 10.537 Section 10.537 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY ARTICLES CONDITIONALLY FREE, SUBJECT TO A REDUCED RATE, ETC. United...

  20. 19 CFR 10.537 - Accessories, spare parts, or tools.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Accessories, spare parts, or tools. 10.537 Section 10.537 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY ARTICLES CONDITIONALLY FREE, SUBJECT TO A REDUCED RATE, ETC. United...

  1. 21 CFR 874.4720 - Mediastinoscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Mediastinoscope and accessories. 874.4720 Section 874.4720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4720 Mediastinoscope...

  2. 21 CFR 874.4720 - Mediastinoscope and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Mediastinoscope and accessories. 874.4720 Section 874.4720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4720 Mediastinoscope...

  3. 21 CFR 874.4720 - Mediastinoscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Mediastinoscope and accessories. 874.4720 Section 874.4720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4720 Mediastinoscope...

  4. 21 CFR 884.4900 - Obstetric table and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Obstetric table and accessories. 884.4900 Section 884.4900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...: patient equipment, support attachments, and cabinets for warming instruments and disposing of wastes....

  5. 21 CFR 884.4900 - Obstetric table and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Obstetric table and accessories. 884.4900 Section 884.4900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...: patient equipment, support attachments, and cabinets for warming instruments and disposing of wastes....

  6. 21 CFR 884.4900 - Obstetric table and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Obstetric table and accessories. 884.4900 Section 884.4900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...: patient equipment, support attachments, and cabinets for warming instruments and disposing of wastes....

  7. 21 CFR 884.4120 - Gynecologic electrocautery and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gynecologic electrocautery and accessories. 884.4120 Section 884.4120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... electrocautery is a device designed to destroy tissue with high temperatures by tissue contact with...

  8. 21 CFR 884.2700 - Intrauterine pressure monitor and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intrauterine pressure monitor and accessories. 884.2700 Section 884.2700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... intrauterine pressure monitor is a device designed to detect and measure intrauterine and amniotic...

  9. 21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... phonocardiographic monitor is a device designed to detect, measure, and record fetal heart sounds electronically,...

  10. 21 CFR 884.1660 - Transcervical endoscope (amnioscope) and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Transcervical endoscope (amnioscope) and accessories. 884.1660 Section 884.1660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND...) Identification. A transcervical endoscope is a device designed to permit direct viewing of the fetus and...

  11. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining...

  12. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining...

  13. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining...

  14. 21 CFR 884.4900 - Obstetric table and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Obstetric table and accessories. 884.4900 Section 884.4900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... obstetric and gynecologic procedures. This generic type of device may include the following...

  15. 21 CFR 872.6640 - Dental operative unit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Dental operative unit and accessories. 872.6640 Section 872.6640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... intended to supply power to and serve as a base for other dental devices, such as a dental handpiece,...

  16. 21 CFR 884.2960 - Obstetric ultrasonic transducer and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Obstetric ultrasonic transducer and accessories. 884.2960 Section 884.2960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN..., amplifiers, signal conditioners with their power supply, connecting cables, and component parts. This...

  17. 21 CFR 876.1500 - Endoscope and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining...

  18. 21 CFR 878.1800 - Speculum and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and...

  19. 21 CFR 878.1800 - Speculum and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and...

  20. 21 CFR 878.1800 - Speculum and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and...

  1. 21 CFR 878.4350 - Cryosurgical unit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cryosurgical unit and accessories. 878.4350 Section 878.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4350 Cryosurgical...

  2. 21 CFR 878.4160 - Surgical camera and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Surgical camera and accessories. 878.4160 Section 878.4160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4160 Surgical...

  3. 21 CFR 878.4370 - Surgical drape and drape accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Surgical drape and drape accessories. 878.4370 Section 878.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4370 Surgical...

  4. 21 CFR 878.4350 - Cryosurgical unit and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cryosurgical unit and accessories. 878.4350 Section 878.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4350 Cryosurgical...

  5. 21 CFR 878.4160 - Surgical camera and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Surgical camera and accessories. 878.4160 Section 878.4160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4160 Surgical...

  6. 21 CFR 878.4350 - Cryosurgical unit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cryosurgical unit and accessories. 878.4350 Section 878.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4350 Cryosurgical...

  7. 21 CFR 878.4370 - Surgical drape and drape accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Surgical drape and drape accessories. 878.4370 Section 878.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4370 Surgical...

  8. 21 CFR 878.4350 - Cryosurgical unit and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cryosurgical unit and accessories. 878.4350 Section 878.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4350 Cryosurgical...

  9. 21 CFR 878.4370 - Surgical drape and drape accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Surgical drape and drape accessories. 878.4370 Section 878.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4370 Surgical...

  10. 21 CFR 878.4350 - Cryosurgical unit and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cryosurgical unit and accessories. 878.4350 Section 878.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4350 Cryosurgical...

  11. 21 CFR 878.1800 - Speculum and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and...

  12. 21 CFR 878.4160 - Surgical camera and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical camera and accessories. 878.4160 Section 878.4160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4160 Surgical...

  13. 21 CFR 878.1800 - Speculum and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Speculum and accessories. 878.1800 Section 878.1800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Diagnostic Devices § 878.1800 Speculum and...

  14. 21 CFR 878.4370 - Surgical drape and drape accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical drape and drape accessories. 878.4370 Section 878.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4370 Surgical...

  15. 21 CFR 878.4370 - Surgical drape and drape accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Surgical drape and drape accessories. 878.4370 Section 878.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4370 Surgical...

  16. 21 CFR 878.4160 - Surgical camera and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Surgical camera and accessories. 878.4160 Section 878.4160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4160 Surgical...

  17. 21 CFR 878.4160 - Surgical camera and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Surgical camera and accessories. 878.4160 Section 878.4160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4160 Surgical...

  18. Diagnosis and treatment of accessory breast cancer in 11 patients

    PubMed Central

    ZHANG, SHUO; YU, YONG-HUA; QU, WEI; ZHANG, YONG; LI, JIA

    2015-01-01

    The present study aimed to investigate the clinical characteristics, diagnosis and treatment of accessory breast cancer, and contribute valuable information regarding this rare tumour to the current literature, ultimately facilitating the development of improved treatment strategies. The present study reported the cases of 11 patients with accessory breast cancer. The patients with accessory breast cancer were admitted between January 2002 and June 2014, and the patient records were retrospectively analysed. All patients presented with a tumour that was localised in the axilla. Out of these patients, there were 8 patients with invasive ductal carcinoma and 3 patients with invasive lobular carcinoma. The follow-up periods for patients ranged between 4 and 54 months. Out of the 5 patients that experienced neoplasm metastases, 4 patients succumbed to the disease. In total, 6 patients remain alive with no evidence of disease. Accessory breast cancer is a progressive tumour, and long-term follow-up is required. A comprehensive treatment strategy may be an effective treatment option for patients; however, the optimal time at which to commence chemotherapy and the role of combined radiotherapy and endocrine therapy require additional investigation. PMID:26622750

  19. 21 CFR 874.4720 - Mediastinoscope and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4720 Mediastinoscope and... device with any of a group of accessory devices which attach to the mediastinoscope and is intended to examine or treat tissue in the area separating the lungs. The device is inserted transthoracicly and...

  20. 21 CFR 874.4720 - Mediastinoscope and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4720 Mediastinoscope and... device with any of a group of accessory devices which attach to the mediastinoscope and is intended to examine or treat tissue in the area separating the lungs. The device is inserted transthoracicly and...

  1. New-type cable accessories for power distribution

    SciTech Connect

    Sanjo, K.; Kawano, K.; Shiraoka, K.; Yasuda, N.; Yatsuka, K.

    1982-12-01

    This paper describes new types of cable accessories for improving the reliability of power distribution cable systems. The practical development of a 25kV-class cable termination, and a waterproof sleeve for cable joints based on heat-shrinkable components made of irradiated polyolefine is discussed. Furthermore, the theoretical and practical data are given.

  2. 21 CFR 876.4890 - Urological table and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Urological table and accessories. 876.4890 Section 876.4890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4890 Urological table...

  3. 21 CFR 876.5090 - Suprapubic urological catheter and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Suprapubic urological catheter and accessories. 876.5090 Section 876.5090 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices §...

  4. 21 CFR 876.4890 - Urological table and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Urological table and accessories. 876.4890 Section 876.4890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4890 Urological table...

  5. 21 CFR 876.5130 - Urological catheter and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Urological catheter and accessories. 876.5130 Section 876.5130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5130...

  6. 21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endoscopic electrosurgical unit and accessories. 876.4300 Section 876.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices §...

  7. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Urine collector and accessories. 876.5250 Section 876.5250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine...

  8. 21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endoscopic electrosurgical unit and accessories. 876.4300 Section 876.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices §...

  9. 21 CFR 876.5010 - Biliary catheter and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Biliary catheter and accessories. 876.5010 Section 876.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5010 Biliary...

  10. 21 CFR 876.4890 - Urological table and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Urological table and accessories. 876.4890 Section 876.4890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4890 Urological table...

  11. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Urine collector and accessories. 876.5250 Section 876.5250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine...

  12. 21 CFR 876.5090 - Suprapubic urological catheter and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suprapubic urological catheter and accessories. 876.5090 Section 876.5090 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices §...

  13. 21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endoscopic electrosurgical unit and accessories. 876.4300 Section 876.4300 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices §...

  14. 21 CFR 876.5010 - Biliary catheter and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Biliary catheter and accessories. 876.5010 Section 876.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5010 Biliary...

  15. 21 CFR 876.5130 - Urological catheter and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Urological catheter and accessories. 876.5130 Section 876.5130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5130...

  16. 21 CFR 876.5130 - Urological catheter and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Urological catheter and accessories. 876.5130 Section 876.5130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5130...

  17. 21 CFR 876.5250 - Urine collector and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Urine collector and accessories. 876.5250 Section 876.5250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5250 Urine...

  18. 21 CFR 876.4890 - Urological table and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Urological table and accessories. 876.4890 Section 876.4890 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4890 Urological table...

  19. 21 CFR 876.5010 - Biliary catheter and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Biliary catheter and accessories. 876.5010 Section 876.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5010 Biliary...

  20. 21 CFR 876.5130 - Urological catheter and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Urological catheter and accessories. 876.5130 Section 876.5130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5130...